The development of a quality appraisal tool for studies of diagnostic reliability (QAREL).
Lucas, Nicholas P; Macaskill, Petra; Irwig, Les; Bogduk, Nikolai
2010-08-01
In systematic reviews of the reliability of diagnostic tests, no quality assessment tool has been used consistently. The aim of this study was to develop a specific quality appraisal tool for studies of diagnostic reliability. Key principles for the quality of studies of diagnostic reliability were identified with reference to epidemiologic principles, existing quality appraisal checklists, and the Standards for Reporting of Diagnostic Accuracy (STARD) and Quality Assessment of Diagnostic Accuracy Studies (QUADAS) resources. Specific items that encompassed each of the principles were developed. Experts in diagnostic research provided feedback on the items that were to form the appraisal tool. This process was iterative and continued until consensus among experts was reached. The Quality Appraisal of Reliability Studies (QAREL) checklist includes 11 items that explore seven principles. Items cover the spectrum of subjects, spectrum of examiners, examiner blinding, order effects of examination, suitability of the time interval among repeated measurements, appropriate test application and interpretation, and appropriate statistical analysis. QAREL has been developed as a specific quality appraisal tool for studies of diagnostic reliability. The reliability of this tool in different contexts needs to be evaluated. Copyright (c) 2010 Elsevier Inc. All rights reserved.
ERIC Educational Resources Information Center
Ward-King, Jessica; Cohen, Ira L.; Penning, Henderika; Holden, Jeanette J. A.
2010-01-01
The Autism Diagnostic Interview-Revised is one of the "gold standard" diagnostic tools for autism spectrum disorders. It is traditionally administered face-to-face. Cost and geographical concerns constrain the employment of the ADI-R for large-scale research projects. The telephone interview is a reasonable alternative, but has not yet been…
Nah, Yong-Hwee; Young, Robyn L; Brewer, Neil; Berlingeri, Genna
2014-03-01
The Autism Detection in Early Childhood (ADEC; Young, 2007) was developed as a Level 2 clinician-administered autistic disorder (AD) screening tool that was time-efficient, suitable for children under 3 years, easy to administer, and suitable for persons with minimal training and experience with AD. A best estimate clinical Diagnostic and Statistical Manual of Mental Disorders (4th ed., text rev.; DSM-IV-TR; American Psychiatric Association, 2000) diagnosis of AD was made for 70 children using all available information and assessment results, except for the ADEC data. A screening study compared these children on the ADEC with 57 children with other developmental disorders and 64 typically developing children. Results indicated high internal consistency (α = .91). Interrater reliability and test-retest reliability of the ADEC were also adequate. ADEC scores reliably discriminated different diagnostic groups after controlling for nonverbal IQ and Vineland Adaptive Behavior Composite scores. Construct validity (using exploratory factor analysis) and concurrent validity using performance on the Autism Diagnostic Observation Schedule (Lord et al., 2000), the Autism Diagnostic Interview-Revised (Le Couteur, Lord, & Rutter, 2003), and DSM-IV-TR criteria were also demonstrated. Signal detection analysis identified the optimal ADEC cutoff score, with the ADEC identifying all children who had an AD (N = 70, sensitivity = 1.0) but overincluding children with other disabilities (N = 13, specificity ranging from .74 to .90). Together, the reliability and validity data indicate that the ADEC has potential to be established as a suitable and efficient screening tool for infants with AD. 2014 APA
Lymph Node Metastases Optical Molecular Diagnostic and Radiation Therapy
2017-03-01
structures and not molecular functions. The one tool commonly used for metastases imaging is nuclear medicine. Positron emission tomography, PET, is...be visualized at a relevant stage., largely because most imaging is based upon structures and not molecular functions. But there are no tools to...system suitable for imaging signals from in small animals on the standard radiation therapy tools. (3) To evaluate the limits on structural , metabolic
Process Diagnostics and Monitoring Using the Multipole Resonance Probe (MRP)
NASA Astrophysics Data System (ADS)
Harhausen, J.; Awakowicz, P.; Brinkmann, R. P.; Foest, R.; Lapke, M.; Musch, T.; Mussenbrock, T.; Oberrath, J.; Ohl, A.; Rolfes, I.; Schulz, Ch.; Storch, R.; Styrnoll, T.
2011-10-01
In this contribution we present the application of the MRP in an industrial plasma ion assisted deposition (PIAD) chamber (Leybold optics SYRUS-pro). The MRP is a novel plasma diagnostic which is suitable for an industrial environment - which means that the proposed method is robust, calibration free, and economical, and can be used for ideal and reactive plasmas alike. In order to employ the MRP as process diagnostics we mounted the probe on a manipulator to obtain spatially resolved information on the electron density and temperature. As monitoring tool the MRP is installed at a fixed position. Even during the deposition process it provides stable measurement results while other diagnostic methods, e.g. the Langmuir probe, may suffer from dielectric coatings. In this contribution we present the application of the MRP in an industrial plasma ion assisted deposition (PIAD) chamber (Leybold optics SYRUS-pro). The MRP is a novel plasma diagnostic which is suitable for an industrial environment - which means that the proposed method is robust, calibration free, and economical, and can be used for ideal and reactive plasmas alike. In order to employ the MRP as process diagnostics we mounted the probe on a manipulator to obtain spatially resolved information on the electron density and temperature. As monitoring tool the MRP is installed at a fixed position. Even during the deposition process it provides stable measurement results while other diagnostic methods, e.g. the Langmuir probe, may suffer from dielectric coatings. Funded by the German Ministry for Education and Research (BMBF, Fkz. 13N10462).
Confocal Laser Scanning Microscopy, a New In Vivo Diagnostic Tool for Schistosomiasis
Holtfreter, Martha Charlotte; Nohr-Łuczak, Constanze; Guthoff, Rudolf Friedrich; Reisinger, Emil Christian
2012-01-01
Background The gold standard for the diagnosis of schistosomiasis is the detection of the parasite's characteristic eggs in urine, stool, or rectal and bladder biopsy specimens. Direct detection of eggs is difficult and not always possible in patients with low egg-shedding rates. Confocal laser scanning microscopy (CLSM) permits non-invasive cell imaging in vivo and is an established way of obtaining high-resolution images and 3-dimensional reconstructions. Recently, CLSM was shown to be a suitable method to visualize Schistosoma mansoni eggs within the mucosa of dissected mouse gut. In this case, we evaluated the suitability of CLSM to detect eggs of Schistosoma haematobium in a patient with urinary schistosomiasis and low egg-shedding rates. Methodology/Principal Findings The confocal laser scanning microscope used in this study was based on a scanning laser system for imaging the retina of a living eye, the Heidelberg Retina Tomograph II, in combination with a lens system (image modality). Standard light cystoscopy was performed using a rigid cystoscope under general anaesthesia. The CLSM endoscope was then passed through the working channel of the rigid cystoscope. The mucosal tissue of the bladder was scanned using CLSM. Schistoma haematobium eggs appeared as bright structures, with the characteristic egg shape and typical terminal spine. Conclusion/Significance We were able to detect schistosomal eggs in the urothelium of a patient with urinary schistosomiasis. Thus, CLSM may be a suitable tool for the diagnosis of schistosomiasis in humans, especially in cases where standard diagnostic tools are not suitable. PMID:22529947
NASA Astrophysics Data System (ADS)
Lau, Katherine; Isabelle, Martin; Lloyd, Gavin R.; Old, Oliver; Shepherd, Neil; Bell, Ian M.; Dorney, Jennifer; Lewis, Aaran; Gaifulina, Riana; Rodriguez-Justo, Manuel; Kendall, Catherine; Stone, Nicolas; Thomas, Geraint; Reece, David
2016-03-01
Despite the demonstrated potential as an accurate cancer diagnostic tool, Raman spectroscopy (RS) is yet to be adopted by the clinic for histopathology reviews. The Stratified Medicine through Advanced Raman Technologies (SMART) consortium has begun to address some of the hurdles in its adoption for cancer diagnosis. These hurdles include awareness and acceptance of the technology, practicality of integration into the histopathology workflow, data reproducibility and availability of transferrable models. We have formed a consortium, in joint efforts, to develop optimised protocols for tissue sample preparation, data collection and analysis. These protocols will be supported by provision of suitable hardware and software tools to allow statistically sound classification models to be built and transferred for use on different systems. In addition, we are building a validated gastrointestinal (GI) cancers model, which can be trialled as part of the histopathology workflow at hospitals, and a classification tool. At the end of the project, we aim to deliver a robust Raman based diagnostic platform to enable clinical researchers to stage cancer, define tumour margin, build cancer diagnostic models and discover novel disease bio markers.
Polarization of Coronal Forbidden Lines
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, Hao; Qu, Zhongquan; Landi Degl’Innocenti, Egidio, E-mail: sayahoro@ynao.ac.cn
Since the magnetic field is responsible for most manifestations of solar activity, one of the most challenging problems in solar physics is the diagnostics of solar magnetic fields, particularly in the outer atmosphere. To this end, it is important to develop rigorous diagnostic tools to interpret polarimetric observations in suitable spectral lines. This paper is devoted to analyzing the diagnostic content of linear polarization imaging observations in coronal forbidden lines. Although this technique is restricted to off-limb observations, it represents a significant tool to diagnose the magnetic field structure in the solar corona, where the magnetic field is intrinsically weakmore » and still poorly known. We adopt the quantum theory of polarized line formation developed in the framework of the density matrix formalism, and synthesize images of the emergent linear polarization signal in coronal forbidden lines using potential-field source-surface magnetic field models. The influence of electronic collisions, active regions, and Thomson scattering on the linear polarization of coronal forbidden lines is also examined. It is found that active regions and Thomson scattering are capable of conspicuously influencing the orientation of the linear polarization. These effects have to be carefully taken into account to increase the accuracy of the field diagnostics. We also found that linear polarization observation in suitable lines can give valuable information on the long-term evolution of the magnetic field in the solar corona.« less
Kurian, S. M.; Williams, A. N.; Gelbart, T.; Campbell, D.; Mondala, T. S.; Head, S. R.; Horvath, S.; Gaber, L.; Thompson, R.; Whisenant, T.; Lin, W.; Langfelder, P.; Robison, E. H.; Schaffer, R. L.; Fisher, J. S.; Friedewald, J.; Flechner, S. M.; Chan, L. K.; Wiseman, A. C.; Shidban, H.; Mendez, R.; Heilman, R.; Abecassis, M. M.; Marsh, C. L.; Salomon, D. R.
2015-01-01
There are no minimally invasive diagnostic metrics for acute kidney transplant rejection (AR), especially in the setting of the common confounding diagnosis, acute dysfunction with no rejection (ADNR). Thus, though kidney transplant biopsies remain the gold standard, they are invasive, have substantial risks, sampling error issues and significant costs and are not suitable for serial monitoring. Global gene expression profiles of 148 peripheral blood samples from transplant patients with excellent function and normal histology (TX; n = 46), AR (n = 63) and ADNR (n = 39), from two independent cohorts were analyzed with DNA microarrays. We applied a new normalization tool, frozen robust multi-array analysis, particularly suitable for clinical diagnostics, multiple prediction tools to discover, refine and validate robust molecular classifiers and we tested a novel one-by-one analysis strategy to model the real clinical application of this test. Multiple three-way classifier tools identified 200 highest value probesets with sensitivity, specificity, positive predictive value, negative predictive value and area under the curve for the validation cohort ranging from 82% to 100%, 76% to 95%, 76% to 95%, 79% to 100%, 84% to 100% and 0.817 to 0.968, respectively. We conclude that peripheral blood gene expression profiling can be used as a minimally invasive tool to accurately reveal TX, AR and ADNR in the setting of acute kidney transplant dysfunction. PMID:24725967
Development and clinical evaluation of a rapid diagnostic kit for feline leukemia virus infection.
Kim, Won-Shik; Chong, Chom-Kyu; Kim, Hak-Yong; Lee, Gyu-Cheol; Jeong, Wooseog; An, Dong-Jun; Jeoung, Hye-Young; Lee, Jae-In; Lee, Young-Ki
2014-01-01
Feline leukemia virus (FeLV) causes a range of neoplastic and degenerative diseases in cats. To obtain a more sensitive and convenient diagnosis of the disease, we prepared monoclonal antibodies specific for the FeLV p27 to develop a rapid diagnostic test with enhanced sensitivity and specificity. Among these antibodies, we identified two clones (hybridomas 8F8B5 and 8G7D1) that specifically bound to FeLV and were very suitable for a diagnostic kit. The affinity constants for 8F8B5 and 8G7D1 were 0.35 × 10⁸ and 0.86 × 10⁸, respectively. To investigate the diagnostic abilities of the rapid kit using these antibodies, we performed several clinical studies. Assessment of analytical sensitivity revealed that the detection threshold of the rapid diagnostic test was 2 ng/mL for recombinant p27 and 12.5 × 10⁴ IU/mL for FeLV. When evaluating 252 cat sera samples, the kit was found to have a kappa value of 0.88 compared to polymerase chain reaction (PCR), indicating a significant correlation between data from the rapid diagnostic test and PCR. Sensitivity and specificity of the kit were 95.2% (20/21) and 98.5% (257/261), respectively. Our results demonstrated that the rapid diagnostic test would be a suitable diagnostic tool for the rapid detection of FeLV infection in cats.
Schmidt, V; Sikasunge, C S; Odongo-Aginya, E; Simukoko, C; Mwanjali, G; Alarakol, S; Ovuga, E; Matuja, W; Kihamia, C; Löscher, T; Winkler, A S; Bretzel, G
2015-03-01
Taenia solium metacestodes/cysts obtained from pig carcasses constitute a primary source for diagnostic tools used for the detection of human cysticercosis. Data on T. solium cyst preparation in Africa is still scarce but required to establish independent reference laboratories. The aim of the present study is a) to present the likely yield of T. solium cyst material by the use of two different preparation methods in the field and b) to investigate its suitability for immunodiagnosis of human cysticercosis. In Zambia, Uganda and Tanzania 670 pigs were screened for T. solium infection. Cysts were prepared by 'shaking method' and 'washing method'. Generated crude antigens were applied in a standard western blot assay. 46 out of 670 pigs (6.9%) were found positive for T. solium (Zambia: 12/367, 3.3%; Uganda: 11/217, 5.1%; Tanzania 23/86, 26.7%). Mean values of 77.7 ml whole cysts, 61.8 ml scolices/membranes and 10.9 ml cyst fluid were obtained per pig. Suitability of collected material for the use as crude antigen and molecular diagnostic techniques was demonstrated. This study clearly shows that T. solium cyst preparation in African settings by simple field methods constitutes an effective way to obtain high quality material as source for diagnostic tools and research purposes.
Dragone, Roberto; Grasso, Gerardo; Muccini, Michele; Toffanin, Stefano
2017-01-01
This mini-review covers the newly developed biosensoristic and chemosensoristic devices described in recent literature for detection of contaminants in both environmental and food real matrices. Current needs in environmental and food surveillance of contaminants require new simplified, sensitive systems, which are portable and allow for rapid and on-site monitoring and diagnostics. Here, we focus on optical and electrochemical bio/chemosensoristic devices as promising tools with interesting analytical features that can be potentially exploited for innovative on-site and real-time applications for diagnostics and monitoring of environmental and food matrices (e.g., agricultural waters and milk). In near future, suitably developed and implemented bio/chemosensoristic devices will be a new and modern technological solution for the identification of new quality and safety marker indexes as well as for a more proper and complete characterization of abovementioned environmental and food matrices. Integrated bio/chemosensoristic devices can also allow an “holistic approach” that may prove to be more suitable for diagnostics of environmental and food real matrices, where the copresence of more bioactive substances is frequent. Therefore, this approach can be focused on the determination of net effect (mixture effect) of bioactive substances present in real matrices. PMID:28529937
Dragone, Roberto; Grasso, Gerardo; Muccini, Michele; Toffanin, Stefano
2017-01-01
This mini-review covers the newly developed biosensoristic and chemosensoristic devices described in recent literature for detection of contaminants in both environmental and food real matrices. Current needs in environmental and food surveillance of contaminants require new simplified, sensitive systems, which are portable and allow for rapid and on-site monitoring and diagnostics. Here, we focus on optical and electrochemical bio/chemosensoristic devices as promising tools with interesting analytical features that can be potentially exploited for innovative on-site and real-time applications for diagnostics and monitoring of environmental and food matrices (e.g., agricultural waters and milk). In near future, suitably developed and implemented bio/chemosensoristic devices will be a new and modern technological solution for the identification of new quality and safety marker indexes as well as for a more proper and complete characterization of abovementioned environmental and food matrices. Integrated bio/chemosensoristic devices can also allow an "holistic approach" that may prove to be more suitable for diagnostics of environmental and food real matrices, where the copresence of more bioactive substances is frequent. Therefore, this approach can be focused on the determination of net effect (mixture effect) of bioactive substances present in real matrices.
Brunner, C; Hoffmann, K; Thiele, T; Schedler, U; Jehle, H; Resch-Genger, U
2015-04-01
Commercial platforms consisting of ready-to-use microarrays printed with target-specific DNA probes, a microarray scanner, and software for data analysis are available for different applications in medical diagnostics and food analysis, detecting, e.g., viral and bacteriological DNA sequences. The transfer of these tools from basic research to routine analysis, their broad acceptance in regulated areas, and their use in medical practice requires suitable calibration tools for regular control of instrument performance in addition to internal assay controls. Here, we present the development of a novel assay-adapted calibration slide for a commercialized DNA-based assay platform, consisting of precisely arranged fluorescent areas of various intensities obtained by incorporating different concentrations of a "green" dye and a "red" dye in a polymer matrix. These dyes present "Cy3" and "Cy5" analogues with improved photostability, chosen based upon their spectroscopic properties closely matching those of common labels for the green and red channel of microarray scanners. This simple tool allows to efficiently and regularly assess and control the performance of the microarray scanner provided with the biochip platform and to compare different scanners. It will be eventually used as fluorescence intensity scale for referencing of assays results and to enhance the overall comparability of diagnostic tests.
Tatarkovič, Michal; Synytsya, Alla; Šťovíčková, Lucie; Bunganič, Bohuš; Miškovičová, Michaela; Petruželka, Luboš; Setnička, Vladimír
2015-02-01
Raman optical activity (ROA) is inherently sensitive to the secondary structure of biomolecules, which makes it a method of interest for finding new approaches to clinical applications based on blood plasma analysis, for instance the diagnostics of several protein-misfolding diseases. Unfortunately, real blood plasma exhibits strong background fluorescence when excited at 532 nm; hence, measuring the ROA spectra appears to be impossible. Therefore, we established a suitable method using a combination of kinetic quenchers, filtering, photobleaching, and a mathematical correction of residual fluorescence. Our method reduced the background fluorescence approximately by 90%, which allowed speedup for each measurement by an average of 50%. In addition, the signal-to-noise ratio was significantly increased, while the baseline distortion remained low. We assume that our method is suitable for the investigation of human blood plasma by ROA and may lead to the development of a new tool for clinical diagnostics.
High density plasmas and new diagnostics: An overview (invited).
Celona, L; Gammino, S; Mascali, D
2016-02-01
One of the limiting factors for the full understanding of Electron Cyclotron Resonance Ion Sources (ECRISs) fundamental mechanisms consists of few types of diagnostic tools so far available for such compact machines. Microwave-to-plasma coupling optimisation, new methods of density overboost provided by plasma wave generation, and magnetostatic field tailoring for generating a proper electron energy distribution function, suitable for optimal ion beams formation, require diagnostic tools spanning across the entire electromagnetic spectrum from microwave interferometry to X-ray spectroscopy; these methods are going to be implemented including high resolution and spatially resolved X-ray spectroscopy made by quasi-optical methods (pin-hole cameras). The ion confinement optimisation also requires a complete control of cold electrons displacement, which can be performed by optical emission spectroscopy. Several diagnostic tools have been recently developed at INFN-LNS, including "volume-integrated" X-ray spectroscopy in low energy domain (2-30 keV, by using silicon drift detectors) or high energy regime (>30 keV, by using high purity germanium detectors). For the direct detection of the spatially resolved spectral distribution of X-rays produced by the electronic motion, a "pin-hole camera" has been developed also taking profit from previous experiences in the ECRIS field. The paper will give an overview of INFN-LNS strategy in terms of new microwave-to-plasma coupling schemes and advanced diagnostics supporting the design of new ion sources and for optimizing the performances of the existing ones, with the goal of a microwave-absorption oriented design of future machines.
Measuring multi-configurational character by orbital entanglement
NASA Astrophysics Data System (ADS)
Stein, Christopher J.; Reiher, Markus
2017-09-01
One of the most critical tasks at the very beginning of a quantum chemical investigation is the choice of either a multi- or single-configurational method. Naturally, many proposals exist to define a suitable diagnostic of the multi-configurational character for various types of wave functions in order to assist this crucial decision. Here, we present a new orbital-entanglement-based multi-configurational diagnostic termed Zs(1). The correspondence of orbital entanglement and static (or non-dynamic) electron correlation permits the definition of such a diagnostic. We chose our diagnostic to meet important requirements such as well-defined limits for pure single-configurational and multi-configurational wave functions. The Zs(1) diagnostic can be evaluated from a partially converged, but qualitatively correct, and therefore inexpensive density matrix renormalisation group wave function as in our recently presented automated active orbital selection protocol. Its robustness and the fact that it can be evaluated at low cost make this diagnostic a practical tool for routine applications.
Mukherjee, Sharmila; Aneja, Satinder; Russell, Paul S S; Gulati, Sheffali; Deshmukh, Vaishali; Sagar, Rajesh; Silberberg, Donald; Bhutani, Vinod K; Pinto, Jennifer M; Durkin, Maureen; Pandey, Ravindra M; Nair, M K C; Arora, Narendra K
2014-06-01
To develop and validate INCLEN Diagnostic Tool for Attention Deficit Hyperactivity Disorder (INDT-ADHD). Diagnostic test evaluation by cross sectional design. Tertiary care pediatric centers. 156 children aged 65-117 months. After randomization, INDT-ADHD and Connors 3 Parent Rating Scale (C3PS) were administered, followed by an expert evaluation by DSM-IV-TR diagnostic criteria. Psychometric evaluation of diagnostic accuracy, validity (construct, criterion and convergent) and internal consistency. INDT-ADHD had 18 items that quantified symptoms and impairment. Attention deficit hyperactivity disorder was identified in 57, 87 and 116 children by expert evaluation, INDT-ADHD and C3PS, respectively. Psychometric parameters of INDT-ADHD for differentiating attention deficit hyperactivity disorder and normal children were: sensitivity 87.7%, specificity 97.2%, positive predictive value 98.0% and negative predictive value 83.3%, whereas for differentiating from other neuro-developmental disorders were 87.7%, 42.9%, 58.1% and 79.4%, respectively. Internal consistency was 0.91. INDT-ADHD has a 4-factor structure explaining 60.4% of the variance. Convergent validity with Conner's Parents Rating Scale was moderate (r =0.73, P= 0.001). INDT-ADHD is suitable for diagnosing attention deficit hyperactivity disorder in Indian children between the ages of 6 to 9 years.
Pharmacologic intervention as an alternative to exercise stress
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gould, K.L.
1987-04-01
Although thallium exercise imaging has served an important role in clinical cardiology, it is significantly limited by suboptimal sensitivity and specificity, particularly in asymptomatic man. The increasing recognition of silent myocardial ischemia, the significant prevalence of coronary artery disease in asymptomatic middle age men, and the frequent occurrence of myocardial infarction without preceding symptoms in 60% of cases emphasizes the need for a more definitive, noninvasive diagnostic test for the presence of coronary artery disease suitable for screening in asymptomatic or symptomatic patients. Intravenous dipyridamole combined with handgrip stress provides a potent stimulus for purposes of diagnostic perfusion imaging. Althoughmore » planar and single photon emission computed tomography (SPECT) imaging also have played an important role, these techniques are seriously hindered by their inability to quantitate radiotracer uptake or image modest differences in maximum relative flow caused by coronary artery stenosis. Accordingly, the combination of dipyridamole-handgrip stress with positron imaging of myocardial perfusion has become a powerful diagnostic tool suitable for routine clinical use. With the availability of generator-produced rubidium-82, dedicated clinically oriented positron cameras, the routine application of positron imaging to clinical cardiology has become feasible. 75 references.« less
Cho, Sung Jin; Lee, Jihoo; Lee, Hyun Jae; Jo, Hyun-Young; Sinniah, Mangalam; Kim, Hak-Yong; Chong, Chom-Kyu; Song, Hyun-Ok
2016-01-01
Rapid diagnostic tests (RDTs) can detect anti-malaria antibodies in human blood. As they can detect parasite infection at the low parasite density, they are useful in endemic areas where light infection and/or re-infection of parasites are common. Thus, malaria antibody tests can be used for screening bloods in blood banks to prevent transfusion-transmitted malaria (TTM), an emerging problem in malaria endemic areas. However, only a few malaria antibody tests are available in the microwell-based assay format and these are not suitable for field application. A novel malaria antibody (Ab)-based RDT using a differential diagnostic marker for falciparum and vivax malaria was developed as a suitable high-throughput assay that is sensitive and practical for blood screening. The marker, merozoite surface protein 1 (MSP1) was discovered by generation of a Plasmodium-specific network and the hierarchical organization of modularity in the network. Clinical evaluation revealed that the novel Malaria Pf/Pv Ab RDT shows improved sensitivity (98%) and specificity (99.7%) compared with the performance of a commercial kit, SD BioLine Malaria P.f/P.v (95.1% sensitivity and 99.1% specificity). The novel Malaria Pf/Pv Ab RDT has potential for use as a cost-effective blood-screening tool for malaria and in turn, reduces TTM risk in endemic areas.
Nucleic Acid-Based Approaches for Detection of Viral Hepatitis
Behzadi, Payam; Ranjbar, Reza; Alavian, Seyed Moayed
2014-01-01
Context: To determining suitable nucleic acid diagnostics for individual viral hepatitis agent, an extensive search using related keywords was done in major medical library and data were collected, categorized, and summarized in different sections. Results: Various types of molecular biology tools can be used to detect and quantify viral genomic elements and analyze the sequences. These molecular assays are proper technologies for rapidly detecting viral agents with high accuracy, high sensitivity, and high specificity. Nonetheless, the application of each diagnostic method is completely dependent on viral agent. Conclusions: Despite rapidity, automation, accuracy, cost-effectiveness, high sensitivity, and high specificity of molecular techniques, each type of molecular technology has its own advantages and disadvantages. PMID:25789132
Portable Diagnostics Technology Assessment for Space Missions. Part 2; Market Survey
NASA Technical Reports Server (NTRS)
Nelson, Emily S.; Chait, Arnon
2010-01-01
A mission to Mars of several years duration requires more demanding standards for all onboard instruments than a 6-month mission to the Moon or the International Space Station. In Part 1, we evaluated generic technologies and suitability to NASA needs. This prior work considered crew safety, device maturity and flightworthiness, resource consumption, and medical value. In Part 2, we continue the study by assessing the current marketplace for reliable Point-of-Care diagnostics. The ultimate goal of this project is to provide a set of objective analytical tools to suggest efficient strategies for reaching specific medical targets for any given space mission as program needs, technological development, and scientific understanding evolve.
The use of digital images in pathology.
Furness, P N
1997-11-01
Digital images are routinely used by the publishing industry, but most diagnostic pathologists are unfamiliar with the technology and its possibilities. This review aims to explain the basic principles of digital image acquisition, storage, manipulation and use, and the possibilities provided not only in research, but also in teaching and in routine diagnostic pathology. Images of natural objects are usually expressed digitally as 'bitmaps'--rectilinear arrays of small dots. The size of each dot can vary, but so can its information content in terms, for example, of colour, greyscale or opacity. Various file formats and compression algorithms are available. Video cameras connected to microscopes are familiar to most pathologists; video images can be converted directly to a digital form by a suitably equipped computer. Digital cameras and scanners are alternative acquisition tools of relevance to pathologists. Once acquired, a digital image can easily be subjected to the digital equivalent of any conventional darkroom manipulation and modern software allows much more flexibility, to such an extent that a new tool for scientific fraud has been created. For research, image enhancement and analysis is an increasingly powerful and affordable tool. Morphometric measurements are, after many predictions, at last beginning to be part of the toolkit of the diagnostic pathologist. In teaching, the potential to create dramatic yet informative presentations is demonstrated daily by the publishing industry; such methods are readily applicable to the classroom. The combination of digital images and the Internet raises many possibilities; for example, instead of seeking one expert diagnostic opinion, one could simultaneously seek the opinion of many, all around the globe. It is inevitable that in the coming years the use of digital images will spread from the laboratory to the medical curriculum and to the whole of diagnostic pathology.
Advanced bioanalytics for precision medicine.
Roda, Aldo; Michelini, Elisa; Caliceti, Cristiana; Guardigli, Massimo; Mirasoli, Mara; Simoni, Patrizia
2018-01-01
Precision medicine is a new paradigm that combines diagnostic, imaging, and analytical tools to produce accurate diagnoses and therapeutic interventions tailored to the individual patient. This approach stands in contrast to the traditional "one size fits all" concept, according to which researchers develop disease treatments and preventions for an "average" patient without considering individual differences. The "one size fits all" concept has led to many ineffective or inappropriate treatments, especially for pathologies such as Alzheimer's disease and cancer. Now, precision medicine is receiving massive funding in many countries, thanks to its social and economic potential in terms of improved disease prevention, diagnosis, and therapy. Bioanalytical chemistry is critical to precision medicine. This is because identifying an appropriate tailored therapy requires researchers to collect and analyze information on each patient's specific molecular biomarkers (e.g., proteins, nucleic acids, and metabolites). In other words, precision diagnostics is not possible without precise bioanalytical chemistry. This Trend article highlights some of the most recent advances, including massive analysis of multilayer omics, and new imaging technique applications suitable for implementing precision medicine. Graphical abstract Precision medicine combines bioanalytical chemistry, molecular diagnostics, and imaging tools for performing accurate diagnoses and selecting optimal therapies for each patient.
Kawano, Shuichi; Maeda, Takuya; Suzuki, Takefumi; Abe, Tatsuhiro; Mikita, Kei; Hamakawa, Yusuke; Ono, Takeshi; Sonehara, Wataru; Miyahira, Yasushi; Kawana, Akihiko
2015-03-01
Loop-mediated isothermal amplification (LAMP) is an innovative molecular technique requiring only a heating device and isothermal conditions to amplify a specific target gene. The results of current microscopic diagnostic tools for pneumocystis pneumonia are not sufficiently consistent for detecting infection with a low-density of Pneumocystis jirovecii. Although polymerase chain reaction (PCR) is highly sensitive, it is not suitable for resource-limited facilities. LAMP is a potential diagnostic replacement for PCR in such settings but a critical disadvantage of DNA extraction was still remained. Therefore, we employed the Procedure for Ultra Rapid Extraction (PURE) kit, which uses a porous material, to isolate the DNA from clinical samples in a simple way in combination with previously reported LAMP procedure for diagnosing PCP. The detection limit of the PURE-LAMP method applied to artificial bronchoalveolar lavage fluid samples was 100 copies/tube, even with the use of massive blood-contaminated solutions. In addition, we concluded the diagnostic procedure within 1 h without the need for additional equipment. PURE-LAMP coupled with suitable primers for specific pathogens has good potential for diagnosing various infectious diseases. Copyright © 2014 Japanese Society of Chemotherapy and The Japanese Association for Infectious Diseases. Published by Elsevier Ltd. All rights reserved.
Multiphoton gradient index endoscopy for evaluation of diseased human prostatic tissue ex vivo
NASA Astrophysics Data System (ADS)
Huland, David M.; Jain, Manu; Ouzounov, Dimitre G.; Robinson, Brian D.; Harya, Diana S.; Shevchuk, Maria M.; Singhal, Paras; Xu, Chris; Tewari, Ashutosh K.
2014-11-01
Multiphoton microscopy can instantly visualize cellular details in unstained tissues. Multiphoton probes with clinical potential have been developed. This study evaluates the suitability of multiphoton gradient index (GRIN) endoscopy as a diagnostic tool for prostatic tissue. A portable and compact multiphoton endoscope based on a 1-mm diameter, 8-cm length GRIN lens system probe was used. Fresh ex vivo samples were obtained from 14 radical prostatectomy patients and benign and malignant areas were imaged and correlated with subsequent H&E sections. Multiphoton GRIN endoscopy images of unfixed and unprocessed prostate tissue at a subcellular resolution are presented. We note several differences and identifying features of benign versus low-grade versus high-grade tumors and are able to identify periprostatic tissues such as adipocytes, periprostatic nerves, and blood vessels. Multiphoton GRIN endoscopy can be used to identify both benign and malignant lesions in ex vivo human prostate tissue and may be a valuable diagnostic tool for real-time visualization of suspicious areas of the prostate.
eap Gene as novel target for specific identification of Staphylococcus aureus.
Hussain, Muzaffar; von Eiff, Christof; Sinha, Bhanu; Joost, Insa; Herrmann, Mathias; Peters, Georg; Becker, Karsten
2008-02-01
The cell surface-associated extracellular adherence protein (Eap) mediates adherence of Staphylococcus aureus to host extracellular matrix components and inhibits inflammation, wound healing, and angiogenesis. A well-characterized collection of S. aureus and non-S. aureus staphylococcal isolates (n = 813) was tested for the presence of the Eap-encoding gene (eap) by PCR to investigate the use of the eap gene as a specific diagnostic tool for identification of S. aureus. Whereas all 597 S. aureus isolates were eap positive, this gene was not detectable in 216 non-S. aureus staphylococcal isolates comprising 47 different species and subspecies of coagulase-negative staphylococci and non-S. aureus coagulase-positive or coagulase-variable staphylococci. Furthermore, non-S. aureus isolates did not express Eap homologs, as verified on the transcriptional and protein levels. Based on these data, the sensitivity and specificity of the newly developed PCR targeting the eap gene were both 100%. Thus, the unique occurrence of Eap in S. aureus offers a promising tool particularly suitable for molecular diagnostics of this pathogen.
Vanoh, Divya; Shahar, Suzana; Rosdinom, Razali; Din, Normah Che; Yahya, Hanis Mastura; Omar, Azahadi
2016-01-01
Background and aim Focus on screening for cognitive impairment has to be given particular importance because of the rising older adult population. Thus, this study aimed to develop and assess a brief screening tool consisting of ten items that can be self-administered by community dwelling older adults (TUA-WELLNESS). Methodology A total of 1,993 noninstitutionalized respondents aged 60 years and above were selected for this study. The dependent variable was mild cognitive impairment (MCI) assessed using neuropsychological test batteries. The items for the screening tool comprised a wide range of factors that were chosen mainly from the analysis of ordinal logistic regression (OLR) and based on past literature. A suitable cut-off point was developed using receiver operating characteristic analysis. Results A total of ten items were included in the screening tool. From the ten items, eight were found to be significant by ordinal logistic regression and the remaining two items were part of the tool because they showed strong association with cognitive impairment in previous studies. The area under curve (AUC), sensitivity, and specificity for cut-off 11 were 0.84%, 83.3%, and 73.4%, respectively. Conclusion TUA-WELLNESS screening tool has been used to screen for major risk factors of MCI among Malaysian older adults. This tool is only suitable for basic MCI risk screening purpose and should not be used for diagnostic purpose. PMID:27274208
Krisher, Sarah; Riley, Alison; Mehta, Khanjan
2014-04-01
The meteoric rise in the prevalence of non-communicable diseases, alongside already high rates of infectious diseases, is exacerbating the 'double disease burden' in the developing world. There is a desperate need for affordable, accessible and ruggedized diagnostic tools that detect diseases early and direct patients to the correct channels. Breath analysis, the science of utilizing biomarkers in the breath for diagnostic measures, is growing rapidly, especially for use in clinical diagnostic settings. Breathalyser technologies are improving scientifically, but are not yet ready for productization and dissemination to address healthcare challenges. How does one ensure that these new biomedical devices will be suitable for use in developing communities? This article presents a comprehensive review of breath analysis technologies followed by a discussion on how such devices can be designed to conform with WHO's ASSURED criteria so as to reach and sustain in developing countries where they are needed the most.
Early Diagnosis of Breast Cancer.
Wang, Lulu
2017-07-05
Early-stage cancer detection could reduce breast cancer death rates significantly in the long-term. The most critical point for best prognosis is to identify early-stage cancer cells. Investigators have studied many breast diagnostic approaches, including mammography, magnetic resonance imaging, ultrasound, computerized tomography, positron emission tomography and biopsy. However, these techniques have some limitations such as being expensive, time consuming and not suitable for young women. Developing a high-sensitive and rapid early-stage breast cancer diagnostic method is urgent. In recent years, investigators have paid their attention in the development of biosensors to detect breast cancer using different biomarkers. Apart from biosensors and biomarkers, microwave imaging techniques have also been intensely studied as a promising diagnostic tool for rapid and cost-effective early-stage breast cancer detection. This paper aims to provide an overview on recent important achievements in breast screening methods (particularly on microwave imaging) and breast biomarkers along with biosensors for rapidly diagnosing breast cancer.
The role of flow cytometry in companion animal diagnostic medicine.
Tarrant, Jacqueline M
2005-11-01
Flow cytometry is a powerful tool for characterising the composition of complex cell populations. The accuracy and precision of this technology for describing and enumerating cells exceeds traditional methods. The number of diagnostic veterinary laboratories with access to a dedicated machine is increasing, and there is the potential to offer a clinical flow cytometry service. The improved availability of monoclonal antibodies (mAb) to cell markers expressed by the leukocytes of companion animals, permits the implementation of comprehensive mAb panels suitable for diagnosis of lympho- and myeloproliferative disease. Reticulated erythrocyte and platelet quantification, antiglobulin assays for immune-mediated cytopenias, lymphocyte subset analysis, and immunophenotyping of lymphoma and leukemia, have been validated for companion animal samples on the flow cytometer. It is now timely to consider the role of flow cytometry in diagnostic practice, and the requirement for quality assurance and standardization of testing procedures.
Novel Use of Ophthalmic pH Paper to Diagnose Malicious Caustic Ingestion in a Pediatric Patient
Bruno, Eric C.
2018-01-01
Occult caustic ingestion in the pediatric population is a challenging diagnosis to make in the emergency department. Failure to suspect and diagnose a caustic ingestion can lead to potentially life-changing comorbidities. Historically, the diagnosis of caustic ingestion has been clinical without any suitable diagnostic tools to aid in the suspicion of occult cases. In this case, we describe a novel use of ophthalmic pH paper to diagnose caustic ingestion in a three-year-old.
Ernst, Corinna; Hahnen, Eric; Engel, Christoph; Nothnagel, Michael; Weber, Jonas; Schmutzler, Rita K; Hauke, Jan
2018-03-27
The use of next-generation sequencing approaches in clinical diagnostics has led to a tremendous increase in data and a vast number of variants of uncertain significance that require interpretation. Therefore, prediction of the effects of missense mutations using in silico tools has become a frequently used approach. Aim of this study was to assess the reliability of in silico prediction as a basis for clinical decision making in the context of hereditary breast and/or ovarian cancer. We tested the performance of four prediction tools (Align-GVGD, SIFT, PolyPhen-2, MutationTaster2) using a set of 236 BRCA1/2 missense variants that had previously been classified by expert committees. However, a major pitfall in the creation of a reliable evaluation set for our purpose is the generally accepted classification of BRCA1/2 missense variants using the multifactorial likelihood model, which is partially based on Align-GVGD results. To overcome this drawback we identified 161 variants whose classification is independent of any previous in silico prediction. In addition to the performance as stand-alone tools we examined the sensitivity, specificity, accuracy and Matthews correlation coefficient (MCC) of combined approaches. PolyPhen-2 achieved the lowest sensitivity (0.67), specificity (0.67), accuracy (0.67) and MCC (0.39). Align-GVGD achieved the highest values of specificity (0.92), accuracy (0.92) and MCC (0.73), but was outperformed regarding its sensitivity (0.90) by SIFT (1.00) and MutationTaster2 (1.00). All tools suffered from poor specificities, resulting in an unacceptable proportion of false positive results in a clinical setting. This shortcoming could not be bypassed by combination of these tools. In the best case scenario, 138 families would be affected by the misclassification of neutral variants within the cohort of patients of the German Consortium for Hereditary Breast and Ovarian Cancer. We show that due to low specificities state-of-the-art in silico prediction tools are not suitable to predict pathogenicity of variants of uncertain significance in BRCA1/2. Thus, clinical consequences should never be based solely on in silico forecasts. However, our data suggests that SIFT and MutationTaster2 could be suitable to predict benignity, as both tools did not result in false negative predictions in our analysis.
Prohl, Annette; Ostermann, Carola; Lohr, Markus; Reinhold, Petra
2014-07-03
There is an ongoing search for alternative animal models in research of respiratory medicine. Depending on the goal of the research, large animals as models of pulmonary disease often resemble the situation of the human lung much better than mice do. Working with large animals also offers the opportunity to sample the same animal repeatedly over a certain course of time, which allows long-term studies without sacrificing the animals. The aim was to establish in vivo sampling methods for the use in a bovine model of a respiratory Chlamydia psittaci infection. Sampling should be performed at various time points in each animal during the study, and the samples should be suitable to study the host response, as well as the pathogen under experimental conditions. Bronchoscopy is a valuable diagnostic tool in human and veterinary medicine. It is a safe and minimally invasive procedure. This article describes the intrabronchial inoculation of calves as well as sampling methods for the lower respiratory tract. Videoendoscopic, intrabronchial inoculation leads to very consistent clinical and pathological findings in all inoculated animals and is, therefore, well-suited for use in models of infectious lung disease. The sampling methods described are bronchoalveolar lavage, bronchial brushing and transbronchial lung biopsy. All of these are valuable diagnostic tools in human medicine and could be adapted for experimental purposes to calves aged 6-8 weeks. The samples obtained were suitable for both pathogen detection and characterization of the severity of lung inflammation in the host.
NASA Astrophysics Data System (ADS)
Niroumand, Amir M.; Homayouni, Hooman; DeVaal, Jake; Golnaraghi, Farid; Kjeang, Erik
2016-08-01
This paper describes a diagnostic tool for in-situ characterization of the rate and distribution of hydrogen transfer leaks in Polymer Electrolyte Membrane (PEM) fuel cell stacks. The method is based on reducing the air flow rate from a high to low value at a fixed current, while maintaining an anode overpressure. At high air flow rates, the reduction in air flow results in lower oxygen concentration in the cathode and therefore reduction in cell voltages. Once the air flow rate in each cell reaches a low value at which the cell oxygen-starves, the voltage of the corresponding cell drops to zero. However, oxygen starvation results from two processes: 1) the electrochemical oxygen reduction reaction which produces current; and 2) the chemical reaction between oxygen and the crossed over hydrogen. In this work, a diagnostic technique has been developed that accounts for the effect of the electrochemical reaction on cell voltage to identify the hydrogen leak rate and number of leaky cells in a fuel cell stack. This technique is suitable for leak characterization during fuel cell operation, as it only requires stack air flow and voltage measurements, which are readily available in an operational fuel cell system.
Advanced DNA-Based Point-of-Care Diagnostic Methods for Plant Diseases Detection.
Lau, Han Yih; Botella, Jose R
2017-01-01
Diagnostic technologies for the detection of plant pathogens with point-of-care capability and high multiplexing ability are an essential tool in the fight to reduce the large agricultural production losses caused by plant diseases. The main desirable characteristics for such diagnostic assays are high specificity, sensitivity, reproducibility, quickness, cost efficiency and high-throughput multiplex detection capability. This article describes and discusses various DNA-based point-of care diagnostic methods for applications in plant disease detection. Polymerase chain reaction (PCR) is the most common DNA amplification technology used for detecting various plant and animal pathogens. However, subsequent to PCR based assays, several types of nucleic acid amplification technologies have been developed to achieve higher sensitivity, rapid detection as well as suitable for field applications such as loop-mediated isothermal amplification, helicase-dependent amplification, rolling circle amplification, recombinase polymerase amplification, and molecular inversion probe. The principle behind these technologies has been thoroughly discussed in several review papers; herein we emphasize the application of these technologies to detect plant pathogens by outlining the advantages and disadvantages of each technology in detail.
Advanced DNA-Based Point-of-Care Diagnostic Methods for Plant Diseases Detection
Lau, Han Yih; Botella, Jose R.
2017-01-01
Diagnostic technologies for the detection of plant pathogens with point-of-care capability and high multiplexing ability are an essential tool in the fight to reduce the large agricultural production losses caused by plant diseases. The main desirable characteristics for such diagnostic assays are high specificity, sensitivity, reproducibility, quickness, cost efficiency and high-throughput multiplex detection capability. This article describes and discusses various DNA-based point-of care diagnostic methods for applications in plant disease detection. Polymerase chain reaction (PCR) is the most common DNA amplification technology used for detecting various plant and animal pathogens. However, subsequent to PCR based assays, several types of nucleic acid amplification technologies have been developed to achieve higher sensitivity, rapid detection as well as suitable for field applications such as loop-mediated isothermal amplification, helicase-dependent amplification, rolling circle amplification, recombinase polymerase amplification, and molecular inversion probe. The principle behind these technologies has been thoroughly discussed in several review papers; herein we emphasize the application of these technologies to detect plant pathogens by outlining the advantages and disadvantages of each technology in detail. PMID:29375588
Design of a Web-tool for diagnostic clinical trials handling medical imaging research.
Baltasar Sánchez, Alicia; González-Sistal, Angel
2011-04-01
New clinical studies in medicine are based on patients and controls using different imaging diagnostic modalities. Medical information systems are not designed for clinical trials employing clinical imaging. Although commercial software and communication systems focus on storage of image data, they are not suitable for storage and mining of new types of quantitative data. We sought to design a Web-tool to support diagnostic clinical trials involving different experts and hospitals or research centres. The image analysis of this project is based on skeletal X-ray imaging. It involves a computerised image method using quantitative analysis of regions of interest in healthy bone and skeletal metastases. The database is implemented with ASP.NET 3.5 and C# technologies for our Web-based application. For data storage, we chose MySQL v.5.0, one of the most popular open source databases. User logins were necessary, and access to patient data was logged for auditing. For security, all data transmissions were carried over encrypted connections. This Web-tool is available to users scattered at different locations; it allows an efficient organisation and storage of data (case report form) and images and allows each user to know precisely what his task is. The advantages of our Web-tool are as follows: (1) sustainability is guaranteed; (2) network locations for collection of data are secured; (3) all clinical information is stored together with the original images and the results derived from processed images and statistical analysis that enable us to perform retrospective studies; (4) changes are easily incorporated because of the modular architecture; and (5) assessment of trial data collected at different sites is centralised to reduce statistical variance.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lundin, J; Clemedson, C -J; Nelson, A
1957-07-01
Male guinea-pigs suffered a loss of cholinesterase activity in plasma amounting to about 30% during the first two days after whole-body roentgen irradiation with 400 r. No changes in the activity of acetylcholinesterase in erythrocytes to be ascribed to the irradiation could be demonstrated during the first two days. A routine method for determination of the cholinesterase activities has been tested but is found less suitable as a diagnostic tool for the early recognition of the effects of irradiation.
Diagnostic approaches for diabetic cardiomyopathy and myocardial fibrosis
Maya, Lisandro; Villarreal, Francisco J.
2009-01-01
In diabetes mellitus, alterations in cardiac structure/function in the absence of ischemic heart disease, hypertension or other cardiac pathologies is termed diabetic cardiomyopathy. In the United States, the prevalence of diabetes mellitus continues to rise and the disease currently affects about 8% of the general population. Hence, it is imperative the use of appropriate diagnostic strategies for diabetic cardiomyopathy, which may help correctly identify the disease at early stages and implement suitable corrective therapies. Currently, there is no single diagnostic method for the identification of diabetic cardiomyopathy. Diabetic cardiomyopathy is known to induce changes in cardiac structure such as, myocardial hypertrophy, fibrosis and fat droplet deposition. Early changes in cardiac function are typically manifested as abnormal diastolic function that with time leads to loss of contractile function. Echocardiography based methods currently stands as the preferred diagnostic approach for diabetic cardiomyopathy, due to its wide availability and economical use. In addition to conventional techniques, magnetic resonance imaging and spectroscopy along with contrast agents are now leading new approaches in the diagnosis of myocardial fibrosis, and cardiac and hepatic metabolic changes. These strategies can be complemented with serum biomarkers so they can offer a clear picture as to diabetes-induced changes in cardiac structure/function even at very early stages of the disease. This review article intends to provide a summary of experimental and routine tools currently available to diagnose diabetic cardiomyopathy induced changes in cardiac structure/function. These tools can be reliably used in either experimental models of diabetes or for clinical applications. PMID:19595694
Assessing Predictive Validity of Pressure Ulcer Risk Scales- A Systematic Review and Meta-Analysis
PARK, Seong-Hi; LEE, Hea Shoon
2016-01-01
Background: The purpose of this study was to present a scientific reason for pressure ulcer risk scales: Cubbin& Jackson modified Braden, Norton, and Waterlow, as a nursing diagnosis tool by utilizing predictive validity of pressure sores. Methods: Articles published between 1966 and 2013 from periodicals indexed in the Ovid Medline, Embase, CINAHL, KoreaMed, NDSL, and other databases were selected using the key word “pressure ulcer”. QUADAS-II was applied for assessment for internal validity of the diagnostic studies. Selected studies were analyzed using meta-analysis with MetaDisc 1.4. Results: Seventeen diagnostic studies with high methodological quality, involving 5,185 patients, were included. In the results of the meta-analysis, sROC AUC of Braden, Norton, and Waterflow scale was over 0.7, showing moderate predictive validity, but they have limited interpretation due to significant differences between studies. In addition, Waterlow scale is insufficient as a screening tool owing to low sensitivity compared with other scales. Conclusion: The contemporary pressure ulcer risk scale is not suitable for uninform practice on patients under standardized criteria. Therefore, in order to provide more effective nursing care for bedsores, a new or modified pressure ulcer risk scale should be developed upon strength and weaknesses of existing tools. PMID:27114977
Modeling Methodologies for Design and Control of Solid Oxide Fuel Cell APUs
NASA Astrophysics Data System (ADS)
Pianese, C.; Sorrentino, M.
2009-08-01
Among the existing fuel cell technologies, Solid Oxide Fuel Cells (SOFC) are particularly suitable for both stationary and mobile applications, due to their high energy conversion efficiencies, modularity, high fuel flexibility, low emissions and noise. Moreover, the high working temperatures enable their use for efficient cogeneration applications. SOFCs are entering in a pre-industrial era and a strong interest for designing tools has growth in the last years. Optimal system configuration, components sizing, control and diagnostic system design require computational tools that meet the conflicting needs of accuracy, affordable computational time, limited experimental efforts and flexibility. The paper gives an overview on control-oriented modeling of SOFC at both single cell and stack level. Such an approach provides useful simulation tools for designing and controlling SOFC-APUs destined to a wide application area, ranging from automotive to marine and airplane APUs.
Molecular malaria diagnostics: A systematic review and meta-analysis.
Roth, Johanna M; Korevaar, Daniël A; Leeflang, Mariska M G; Mens, Pètra F
2016-01-01
Accurate diagnosis of malaria is essential for identification and subsequent treatment of the disease. Currently, microscopy and rapid diagnostic tests are the most commonly used diagnostics, next to treatment based on clinical signs only. These tests are easy to deploy, but have a relatively high detection limit. With declining prevalence in many areas, there is an increasing need for more sensitive diagnostics. Molecular tools may be a suitable alternative, although costs and technical requirements currently hamper their implementation in resource limited settings. A range of (near) point-of-care diagnostics is therefore under development, including simplifications in sample preparation, amplification and/or read-out of the test. Accuracy data, in combination with technical characteristics, are essential in determining which molecular test, if any, would be the most promising to be deployed. This review presents a comprehensive overview of the currently available molecular malaria diagnostics, ranging from well-known tests to platforms in early stages of evaluation, and systematically evaluates their published accuracy. No important difference in accuracy was found between the most commonly used PCR-based assays (conventional, nested and real-time PCR), with most of them having high sensitivity and specificity, implying that there are no reasons other than practical ones to choose one technique over the other. Loop-mediated isothermal amplification and other (novel) diagnostics appear to be highly accurate as well, with some offering potential to be used in resource-limited settings.
Vasileva Wand, Nadina I; Bonney, Laura C; Watson, Robert J; Graham, Victoria; Hewson, Roger
2018-06-13
The sudden and explosive expansion of Zika virus (ZIKV) from the African continent through Oceania and culminating in the outbreak in South America has highlighted the importance of new rapid point-of-care diagnostic tools for the control and prevention of transmission. ZIKV infection has devastating consequences, such as neurological congenital malformations in infants born to infected mothers and Guillain-Barré syndrome in adults. Additionally, its potential for transmission through vector bites, as well as from person to person through blood transfusions and sexual contact, are important considerations for prompt diagnosis. Recombinase polymerase amplification (RPA), an isothermal method, was developed as an alternative field-applicable assay to PCR. Here we report the development of a novel ZIKV real-time reverse transcriptase RPA (RT-RPA) assay capable of detecting a range of different ZIKV strains from a variety of geographical locations. The ZIKV RT-RPA was shown to be highly sensitive, being capable of detecting as few as five copies of target nucleic acid per reaction, and suitable for use with a battery-operated portable device. The ZIKV RT-RPA demonstrated 100 % specificity and 83 % sensitivity in clinical samples. Furthermore, we determined that the ZIKV RT-RPA is a versatile assay that can be applied to crude samples, such as saliva and serum, and can be used as a vector surveillance tool on crude mosquito homogenates. Therefore, the developed ZIKV RT-RPA is a useful diagnostic tool that can be transferred to a resource-limited location, eliminating the need for a specialized and sophisticated laboratory environment and highly trained staff.
Odenbach, Jeffrey; Newton, Amanda; Gokiert, Rebecca; Falconer, Cathy; Courchesne, Craig; Campbell, Sandra; Curtis, Sarah J
2014-03-02
Pediatric injury is highly prevalent and has significant impact both physically and emotionally. The majority of pediatric injuries are treated in emergency departments (EDs), where treatment of physical injuries is the main focus. In addition to physical trauma, children often experience significant psychological trauma, and the development of acute stress disorder (ASD) and post-traumatic stress disorder (PTSD) is common. The consequences of failing to recognize and treat children with ASD and PTSD are significant and extend into adulthood. Currently, screening guidelines to identify children at risk for developing these stress disorders are not evident in the pediatric emergency setting. The goal of this systematic review is to summarize evidence on the psychometric properties, diagnostic accuracy, and clinical utility of screening tools that identify or predict PTSD secondary to physical injury in children. Specific research objectives are to: (1) identify, describe, and critically evaluate instruments available to screen for PTSD in children; (2) review and synthesize the test-performance characteristics of these tools; and (3) describe the clinical utility of these tools with focus on ED suitability. Computerized databases including MEDLINE, EMBASE, CINAHL, ISI Web of Science and PsycINFO will be searched in addition to conference proceedings, textbooks, and contact with experts. Search terms will include MeSH headings (post-traumatic stress or acute stress), (pediatric or children) and diagnosis. All articles will be screened by title/abstract and articles identified as potentially relevant will be retrieved in full text and assessed by two independent reviewers. Quality assessment will be determined using the QUADAS-2 tool. Screening tool characteristics, including type of instrument, number of items, administration time and training administrators level, will be extracted as well as gold standard diagnostic reference properties and any quantitative diagnostic data (specificity, positive and negative likelihood/odds ratios) where appropriate. Identifying screening tools to recognize children at risk of developing stress disorders following trauma is essential in guiding early treatment and minimizing long-term sequelae of childhood stress disorders. This review aims to identify such screening tools in efforts to improve routine stress disorder screening in the pediatric ED setting. PROSPERO registration: CRD42013004893.
Diagnostic validation of three test methods for detection of cyprinid herpesvirus 3 (CyHV-3).
Clouthier, Sharon C; McClure, Carol; Schroeder, Tamara; Desai, Megan; Hawley, Laura; Khatkar, Sunita; Lindsay, Melissa; Lowe, Geoff; Richard, Jon; Anderson, Eric D
2017-03-06
Cyprinid herpesvirus 3 (CyHV-3) is the aetiological agent of koi herpesvirus disease in koi and common carp. The disease is notifiable to the World Organisation for Animal Health. Three tests-quantitative polymerase chain reaction (qPCR), conventional PCR (cPCR) and virus isolation by cell culture (VI)-were validated to assess their fitness as diagnostic tools for detection of CyHV-3. Test performance metrics of diagnostic accuracy were sensitivity (DSe) and specificity (DSp). Repeatability and reproducibility were measured to assess diagnostic precision. Estimates of test accuracy, in the absence of a gold standard reference test, were generated using latent class models. Test samples originated from wild common carp naturally exposed to CyHV-3 or domesticated koi either virus free or experimentally infected with the virus. Three laboratories in Canada participated in the precision study. Moderate to high repeatability (81 to 99%) and reproducibility (72 to 97%) were observed for the qPCR and cPCR tests. The lack of agreement observed between some of the PCR test pair results was attributed to cross-contamination of samples with CyHV-3 nucleic acid. Accuracy estimates for the PCR tests were 99% for DSe and 93% for DSp. Poor precision was observed for the VI test (4 to 95%). Accuracy estimates for VI/qPCR were 90% for DSe and 88% for DSp. Collectively, the results show that the CyHV-3 qPCR test is a suitable tool for surveillance, presumptive diagnosis and certification of individuals or populations as CyHV-3 free.
Spatially resolved density and ionization measurements of shocked foams using x-ray fluorescence
DOE Office of Scientific and Technical Information (OSTI.GOV)
MacDonald, M. J.; Keiter, P. A.; Montgomery, D. S.
2016-09-28
We present experiments at the Trident laser facility demonstrating the use of x-ray fluorescence (XRF) to simultaneously measure density, ionization state populations, and electron temperature in shocked foams. An imaging x-ray spectrometer obtained spatially resolved measurements of Ti K-α emission. Density profiles were measured from K-α intensity. Ti ionization state distributions and electron temperatures were inferred by fitting K-α spectra to spectra from CRETIN simulations. This work shows that XRF provides a powerful tool to complement other diagnostics to make equation of state measurements of shocked materials containing a suitable tracer element.
Vocational guidance during the Depression: phrenology versus applied psychology.
Risse, G B
1976-04-01
The paper describes the design and use of a machine, the "Psychograph," which automatically measured the size and shape of the skull and provided evaluations of mental traits according to phrenological principles. Developed in 1930, the psychograph was billed as a diagnostic tool capable of providing suitable vocational guidance to the thousands of unemployed as a result of the Depression. Its appearance prompted a vigorous opposition from the Psychology Department at the University of Minnesota, especially in the person of Donald L. Paterson. Subsequently, the psychograph was merely exploited for its entertainment value and disappeared after the 1933 World's Fair in Chicago.
PCR testing for diagnosis of Ichthyophonus hoferi: reply to LaPatra & Kocan (2013).
Hamazaki, Toshihide; Kahler, Eryn; Borba, Bonnie M; Burton, Tamara
2013-11-06
LaPatra & Kocan (2013) critiqued our paper Hamazaki et al. (2013; Dis Aquat Org 105:21-25) for data not supporting the conclusions of 'PCR testing is as accurate as culture…', but they neither pointed out what part of our data did not support our conclusion, nor did they provide any contrary scientific evidence supporting their argument that PCR testing is less accurate than culture. In the absence of any contradictory data, we stand by our data and our conclusion: PCR test is as suitable as culture as a diagnostic and field surveillance tool.
NASA Astrophysics Data System (ADS)
Kern, Bastian; Jöckel, Patrick
2016-10-01
Numerical climate and weather models have advanced to finer scales, accompanied by large amounts of output data. The model systems hit the input and output (I/O) bottleneck of modern high-performance computing (HPC) systems. We aim to apply diagnostic methods online during the model simulation instead of applying them as a post-processing step to written output data, to reduce the amount of I/O. To include diagnostic tools into the model system, we implemented a standardised, easy-to-use interface based on the Modular Earth Submodel System (MESSy) into the ICOsahedral Non-hydrostatic (ICON) modelling framework. The integration of the diagnostic interface into the model system is briefly described. Furthermore, we present a prototype implementation of an advanced online diagnostic tool for the aggregation of model data onto a user-defined regular coarse grid. This diagnostic tool will be used to reduce the amount of model output in future simulations. Performance tests of the interface and of two different diagnostic tools show, that the interface itself introduces no overhead in form of additional runtime to the model system. The diagnostic tools, however, have significant impact on the model system's runtime. This overhead strongly depends on the characteristics and implementation of the diagnostic tool. A diagnostic tool with high inter-process communication introduces large overhead, whereas the additional runtime of a diagnostic tool without inter-process communication is low. We briefly describe our efforts to reduce the additional runtime from the diagnostic tools, and present a brief analysis of memory consumption. Future work will focus on optimisation of the memory footprint and the I/O operations of the diagnostic interface.
How to: evaluate a diagnostic test.
Leeflang, Mariska M G; Allerberger, Franz
2018-06-12
The development of an in vitro diagnostic test from a good idea to a clinically relevant tool takes several steps, with more stringent requirements at every step. This article aims to summarize the necessary questions to be asked about a test and to illustrate study designs answering these questions. We also aim to relate the Regulation (EU) 2017/746 to the needs of evidence-based diagnostic testing, where applicable. We used literature on evidence-based diagnostics, a text book on clinical trials in the development and marketing of medical devices and the English version of Regulation 2017/746 of the European Parliament and of the Council on in vitro diagnostic medical devices. The combination of different test uses and different stages of development determine the required test characteristics and suitability of study designs. In an earlier stage of test development it may be crucial to know whether a test can differentiate diseased persons from healthy controls, while this tells us little about how a test will perform in practice. Later stages focus on the diagnostic accuracy of a test in a clinically relevant situation. However, a test that perfectly distinguishes between patients with and without a certain condition may still have little effect on patient outcomes. Therefore, randomized controlled trials of testing may be needed, as well as post-marketing monitoring. Both researchers and users of tests need to be aware of the limitations of diagnostic test accuracy and realize that accuracy is only indirectly linked to people's health status. Copyright © 2018. Published by Elsevier Ltd.
Fluorescence Sensing Using DNA Aptamers in Cancer Research and Clinical Diagnostics
Musumeci, Domenica; Platella, Chiara; Riccardi, Claudia; Moccia, Federica
2017-01-01
Among the various advantages of aptamers over antibodies, remarkable is their ability to tolerate a large number of chemical modifications within their backbone or at the termini without losing significant activity. Indeed, aptamers can be easily equipped with a wide variety of reporter groups or coupled to different carriers, nanoparticles, or other biomolecules, thus producing valuable molecular recognition tools effective for diagnostic and therapeutic purposes. This review reports an updated overview on fluorescent DNA aptamers, designed to recognize significant cancer biomarkers both in soluble or membrane-bound form. In many examples, the aptamer secondary structure switches induced by target recognition are suitably translated in a detectable fluorescent signal using either fluorescently-labelled or label-free aptamers. The fluorescence emission changes, producing an enhancement (“signal-on”) or a quenching (“signal-off”) effect, directly reflect the extent of the binding, thereby allowing for quantitative determination of the target in bioanalytical assays. Furthermore, several aptamers conjugated to fluorescent probes proved to be effective for applications in tumour diagnosis and intraoperative surgery, producing tumour-type specific, non-invasive in vivo imaging tools for cancer pre- and post-treatment assessment. PMID:29261171
Microfluidic devices for stem-cell cultivation, differentiation and toxicity testing
NASA Astrophysics Data System (ADS)
Becker, Holger; Hansen-Hagge, Thomas; Kurtz, Andreas; Mrowka, Ralf; Wölfl, Stefan; Gärtner, Claudia
2017-02-01
The development of new drugs is time-consuming, extremely expensive and often promising drug candidates fail in late stages of the development process due to the lack of suitable tools to either predict toxicological effects or to test drug candidates in physiologically relevant environments prior to clinical tests. We therefore try to develop diagnostic multiorgan microfluidic chips based on patient specific induced pluripotent stem cell (iPS) technology to explore liver dependent toxic effects of drugs on individual human tissues such as liver or kidney cells. Based initially on standardized microfluidic modules for cell culture, we have developed integrated microfluidic devices which contain different chambers for cell/tissue cultivation. The devices are manufactured using injection molding of thermoplastic polymers such as polystyrene or cyclo-olefin polymer. In the project, suitable surface modification methods of the used materials had to be explored. We have been able to successfully demonstrate the seeding, cultivation and further differentiation of modified iPS, as shown by the use of differentiation markers, thus providing a suitable platform for toxicity testing and potential tissue-tissue interactions.
A diagnostic for quantifying heat flux from a thermite spray
DOE Office of Scientific and Technical Information (OSTI.GOV)
E. P. Nixon; M. L. Pantoya; D. J. Prentice
2010-02-01
Characterizing the combustion behaviors of energetic materials requires diagnostic tools that are often not readily or commercially available. For example, a jet of thermite spray provides a high temperature and pressure reaction that can also be highly corrosive and promote undesirable conditions for the survivability of any sensor. Developing a diagnostic to quantify heat flux from a thermite spray is the objective of this study. Quick response sensors such as thin film heat flux sensors cannot survive the harsh conditions of the spray, but more rugged sensors lack the response time for the resolution desired. A sensor that will allowmore » for adequate response time while surviving the entire test duration was constructed. The sensor outputs interior temperatures of the probes at known locations and utilizes an inverse heat conduction code to calculate heat flux values. The details of this device are discussed and illustrated. Temperature and heat flux measurements of various thermite sprays are reported. Results indicate that this newly designed heat flux sensor provides quantitative data with good repeatability suitable for characterizing energetic material combustion.« less
Accuracy of Immunofluorescence in the Diagnosis of Primary Ciliary Dyskinesia
Frost, Emily; Dixon, Mellisa; Ollosson, Sarah; Kilpin, Kate; Patel, Mitali; Scully, Juliet; Rogers, Andrew V.; Mitchison, Hannah M.; Bush, Andrew; Hogg, Claire
2017-01-01
Rationale: The standard approach to diagnosis of primary ciliary dyskinesia (PCD) in the United Kingdom consists of assessing ciliary function by high-speed microscopy and ultrastructure by election microscopy, but equipment and expertise is not widely available internationally. The identification of biallelic disease-causing mutations is also diagnostic, but many disease-causing genes are unknown, and testing is not widely available outside the United States. Fluorescent antibodies to ciliary proteins are used to validate research genetic studies, but diagnostic utility in this disease has not been systematically evaluated. Objectives: To determine utility of a panel of six fluorescent labeled antibodies as a diagnostic tool for PCD. Methods: The study used immunofluorescent labeling of nasal brushings from a discovery cohort of 35 patients diagnosed with PCD by ciliary ultrastructure, and a diagnostic accuracy cohort of 386 patients referred with symptoms suggestive of disease. The results were compared with diagnostic outcome. Measurements and Main Results: Immunofluorescence correctly identified mislocalized or absent staining in 100% of the discovery cohort. In the diagnostic cohort immunofluorescence successfully identified 22 of 25 patients with PCD and normal staining in all 252 in whom PCD was considered highly unlikely. In addition, immunofluorescence provided a result in 55% (39) of cases that were previously inconclusive. Immunofluorescence results were available within 14 days, costing $187 per sample compared with electron microscopy (27 days; cost $1,452). Conclusions: Immunofluorescence is a highly specific diagnostic test for PCD, and it improves the speed and availability of diagnostic testing. However, sensitivity is limited and immunofluorescence is not suitable as a stand-alone test. PMID:28199173
Hybrid approach for robust diagnostics of cutting tools
NASA Astrophysics Data System (ADS)
Ramamurthi, K.; Hough, C. L., Jr.
1994-03-01
A new multisensor based hybrid technique has been developed for robust diagnosis of cutting tools. The technique combines the concepts of pattern classification and real-time knowledge based systems (RTKBS) and draws upon their strengths; learning facility in the case of pattern classification and a higher level of reasoning in the case of RTKBS. It eliminates some of their major drawbacks: false alarms or delayed/lack of diagnosis in case of pattern classification and tedious knowledge base generation in case of RTKBS. It utilizes a dynamic distance classifier, developed upon a new separability criterion and a new definition of robust diagnosis for achieving these benefits. The promise of this technique has been proven concretely through an on-line diagnosis of drill wear. Its suitability for practical implementation is substantiated by the use of practical, inexpensive, machine-mounted sensors and low-cost delivery systems.
Water facilities in retrospect and prospect: An illuminating tool for vehicle design
NASA Technical Reports Server (NTRS)
Erickson, G. E.; Peak, D. J.; Delfrate, J.; Skow, A. M.; Malcolm, G. N.
1986-01-01
Water facilities play a fundamental role in the design of air, ground, and marine vehicles by providing a qualitative, and sometimes quantitative, description of complex flow phenomena. Water tunnels, channels, and tow tanks used as flow-diagnostic tools have experienced a renaissance in recent years in response to the increased complexity of designs suitable for advanced technology vehicles. These vehicles are frequently characterized by large regions of steady and unsteady three-dimensional flow separation and ensuing vortical flows. The visualization and interpretation of the complicated fluid motions about isolated vehicle components and complete configurations in a time and cost effective manner in hydrodynamic test facilities is a key element in the development of flow control concepts, and, hence, improved vehicle designs. A historical perspective of the role of water facilities in the vehicle design process is presented. The application of water facilities to specific aerodynamic and hydrodynamic flow problems is discussed, and the strengths and limitations of these important experimental tools are emphasized.
Willi, Barbara; Meli, Marina L; Lüthy, Ruedi; Honegger, Hanspeter; Wengi, Nicole; Hoelzle, Ludwig E; Reusch, Claudia E; Lutz, Hans; Hofmann-Lehmann, Regina
2009-12-01
Hemotropic mycoplasmas (hemoplasmas) are the causative agents of infectious anemia in several mammalian species. Their zoonotic potential has recently been substantiated by the identification of a feline hemoplasma isolate in an immunocompromised human patient. Although species-specific diagnostic molecular methods have been developed, their application as screening tools is limited due to the species diversity of hemoplasmas. The goals of this study were to develop a universal hemoplasma screening assay with broad specificity based on the SYBR green PCR principle, to compare the assay with hemoplasma-specific TaqMan PCR, and to analyze potential tick vectors and human blood samples to address the zoonotic potential. The newly developed PCR assay based on the 16S rRNA gene amplified feline, canine, bovine, porcine, camelid, and murine hemoplasmas, as well as Mycoplasma penetrans and Mycoplasma pneumoniae. The lower detection limit for feline and canine hemoplasmas was 1 to 10 copies/PCR. The assay exhibited 98.2% diagnostic sensitivity and 92.1% diagnostic specificity for feline hemoplasmas. All 1,950 Ixodes ticks were PCR negative, suggesting that Ixodes ticks are not relevant vectors for the above-mentioned hemoplasma species in Switzerland. None of the 414 blood samples derived from anemic or immunocompromised human patients revealed a clear positive result. The SYBR green PCR assay described here is a suitable tool to screen for known and so-far-undiscovered hemoplasma species. Positive results should be confirmed by specific TaqMan PCR or sequencing.
Knapp, Karen
2013-01-01
Assessment of diagnostic image quality in gynaecological ultrasound is an important aspect of imaging department quality assurance. This may be addressed through audit, but who should undertake the audit, what should be measured and how, remains contentious. The aim of this study was to identify whether peer audit is a suitable method of assessing the diagnostic quality of gynaecological ultrasound images. Nineteen gynaecological ultrasound studies were independently assessed by six sonographers utilising a pilot version of an audit tool. Outcome measures were levels of inter-rater agreement using different data collection methods (binary scores, Likert scale, continuous scale), effect of ultrasound study difficulty on study score and whether systematic differences were present between reviewers of different clinical grades and length of experience. Inter-rater agreement ranged from moderate to good depending on the data collection method. A continuous scale gave the highest level of inter-rater agreement with an intra-class correlation coefficient of 0.73. A strong correlation (r = 0.89) between study difficulty and study score was yielded. Length of clinical experience between reviewers had no effect on the audit scores, but individuals of a higher clinical grade gave significantly lower scores than those of a lower grade (p = 0.04). Peer audit is a promising tool in the assessment of ultrasound image quality. Continuous scales seem to be the best method of data collection implying a strong element of heuristically driven decision making by reviewing ultrasound practitioners. PMID:27433192
Zou, Yaru; Tong, Jianjing; Leng, Haiyan; Jiang, Jingwei; Pan, Meng; Chen, Zi
2017-06-20
18F-fluorodeoxyglucose (18F-FDG) positron emission tomography (PET) and PET/CT have become two of the most powerful tools for malignant lymphoma exploration, but their diagnostic role in primary central nervous system lymphoma (PCNSL) is still disputed. The purpose of our study is to identify the usefulness of 18F-FDG PET and PET/CT for detecting PCNSL. A total of 129 patients, obtained from eight eligible studies, were included for this systematic review and meta-analysis. The performance of 18F-FDG PET and PET/CT for diagnosing PCNSL were as follows: the pooled sensitivity was 0.88 (95% CI: 0.80-0.94), specificity was 0.86 (95% CI: 0.73-0.94), positive likelihood ratio (PLR) was 3.99 (95% CI: 2.31-6.90), negative likelihood ratio (NLR) was 0.11 (95% CI: 0.04-0.32), and diagnostic odds ratio (DOR) was 33.40 (95% CI: 10.40-107.3). In addition, the area under the curve (AUC) and Q index were 0.9192 and 0.8525, respectively. PubMed/MEDLINE, Embase and Cochrane Library were systematically searched for potential publications (last updated on July 16th, 2016). Reference lists of included articles were also checked. Original articles that reported data on patients who were suspected of having PCNSL were considered suitable for inclusion. The sensitivities and specificities of 18F-FDG PET and PET/CT in each study were evaluated. The Stata software and Meta-Disc software were employed in the process of data analysis. 18F-FDG PET and PET/CT showed considerable accuracy in identifying PCNSL in immunocompetent patients and could be a valuable radiological diagnostic tool for PCNSL.
Borgna, F; Ballan, M; Corradetti, S; Vettorato, E; Monetti, A; Rossignoli, M; Manzolaro, M; Scarpa, D; Mazzi, U; Realdon, N; Andrighetto, A
2017-09-01
Radiopharmaceuticals represent a fundamental tool for nuclear medicine procedures, both for diagnostic and therapeutic purposes. The present work aims to explore the Isotope Separation On-Line (ISOL) technique for the production of carrier-free radionuclides for nuclear medicine at SPES, a nuclear physics facility under construction at INFN-LNL. Stable ion beams of strontium, yttrium and iodine were produced using the SPES test bench (Front-End) to simulate the production of 89 Sr, 90 Y, 125 I and 131 I and collected with good efficiency on suitable targets. Copyright © 2017 Elsevier Ltd. All rights reserved.
Spatially resolved density and ionization measurements of shocked foams using x-ray fluorescence
DOE Office of Scientific and Technical Information (OSTI.GOV)
MacDonald, M. J.; Keiter, P. A.; Montgomery, D. S.
2016-09-22
We present experiments at the Trident laser facility demonstrating the use of x-ray fluorescence (XRF) to simultaneously measure density, ionization state populations, and electron temperature in shocked foams. An imaging x-ray spectrometer was used to obtain spatially-resolved measurements of Ti K-more » $$\\alpha$$ emission. Density profiles were measured from K-$$\\alpha$$ intensity. Ti ionization state distributions and electron temperatures were inferred by fitting K-$$\\alpha$$ spectra to spectra from CRETIN simulations. This study shows that XRF provides a powerful tool to complement other diagnostics to make equation of state measurements of shocked materials containing a suitable tracer element.« less
Ligand-directed profiling of organelles with internalizing phage libraries
Dobroff, Andrey S.; Rangel, Roberto; Guzman-Roja, Liliana; Salmeron, Carolina C.; Gelovani, Juri G.; Sidman, Richard L.; Bologa, Cristian G.; Oprea, Tudor I.; Brinker, C. Jeffrey; Pasqualini, Renata; Arap, Wadih
2015-01-01
Phage display is a resourceful tool to, in an unbiased manner, discover and characterize functional protein-protein interactions, to create vaccines, and to engineer peptides, antibodies, and other proteins as targeted diagnostic and/or therapeutic agents. Recently, our group has developed a new class of internalizing phage (iPhage) for ligand-directed targeting of organelles and/or to identify molecular pathways within live cells. This unique technology is suitable for applications ranging from fundamental cell biology to drug development. Here we describe the method for generating and screening the iPhage display system, and explain how to select and validate candidate internalizing homing peptide. PMID:25640897
NASA Technical Reports Server (NTRS)
Richard, Jacques C.
1995-01-01
This paper presents a dynamic model of an internal combustion engine coupled to a variable pitch propeller. The low-order, nonlinear time-dependent model is useful for simulating the propulsion system of general aviation single-engine light aircraft. This model is suitable for investigating engine diagnostics and monitoring and for control design and development. Furthermore, the model may be extended to provide a tool for the study of engine emissions, fuel economy, component effects, alternative fuels, alternative engine cycles, flight simulators, sensors, and actuators. Results show that the model provides a reasonable representation of the propulsion system dynamics from zero to 10 Hertz.
LAMP detection assays for boxwood blight pathogens: A comparative genomics approach
DOE Office of Scientific and Technical Information (OSTI.GOV)
Malapi-Wight, Martha; Demers, Jill E.; Veltri, Daniel
Rapid and accurate molecular diagnostic tools are critical to efforts to minimize the impact and spread of emergent pathogens. The identification of diagnostic markers for novel pathogens presents several challenges, especially in the absence of information about population diversity and where genetic resources are limited. The objective of this study was to use comparative genomics datasets to find unique target regions suitable for the diagnosis of two fungal species causing a newly emergent blight disease of boxwood. Candidate marker regions for loop-mediated isothermal amplification (LAMP) assays were identified from draft genomes of Calonectria henricotiae and C. pseudonaviculata, as well asmore » three related species not associated with this disease. To increase the probability of identifying unique targets, we used three approaches to mine genome datasets, based on (i) unique regions, (ii) polymorphisms, and (iii) presence/absence of regions across datasets. From a pool of candidate markers, we demonstrate LAMP assay specificity by testing related fungal species, common boxwood pathogens, and environmental samples containing 445 diverse fungal taxa. In conclusion, this comparative-genomics-based approach to the development of LAMP diagnostic assays is the first of its kind for fungi and could be easily applied to diagnostic marker development for other newly emergent plant pathogens.« less
LAMP detection assays for boxwood blight pathogens: A comparative genomics approach
Malapi-Wight, Martha; Demers, Jill E.; Veltri, Daniel; ...
2016-05-20
Rapid and accurate molecular diagnostic tools are critical to efforts to minimize the impact and spread of emergent pathogens. The identification of diagnostic markers for novel pathogens presents several challenges, especially in the absence of information about population diversity and where genetic resources are limited. The objective of this study was to use comparative genomics datasets to find unique target regions suitable for the diagnosis of two fungal species causing a newly emergent blight disease of boxwood. Candidate marker regions for loop-mediated isothermal amplification (LAMP) assays were identified from draft genomes of Calonectria henricotiae and C. pseudonaviculata, as well asmore » three related species not associated with this disease. To increase the probability of identifying unique targets, we used three approaches to mine genome datasets, based on (i) unique regions, (ii) polymorphisms, and (iii) presence/absence of regions across datasets. From a pool of candidate markers, we demonstrate LAMP assay specificity by testing related fungal species, common boxwood pathogens, and environmental samples containing 445 diverse fungal taxa. In conclusion, this comparative-genomics-based approach to the development of LAMP diagnostic assays is the first of its kind for fungi and could be easily applied to diagnostic marker development for other newly emergent plant pathogens.« less
[Microbiological point of care tests].
Book, Malte; Lehmann, Lutz Eric; Zhang, Xianghong; Stüber, Frank
2010-11-01
It is well known that the early initiation of a specific antiinfective therapy is crucial to reduce the mortality in severe infection. Procedures culturing pathogens are the diagnostic gold standard in such diseases. However, these methods yield results earliest between 24 to 48 hours. Therefore, severe infections such as sepsis need to be treated with an empirical antimicrobial therapy, which is ineffective in an unknown fraction of these patients. Today's microbiological point of care tests are pathogen specific and therefore not appropriate for an infection with a variety of possible pathogens. Molecular nucleic acid diagnostics such as polymerase chain reaction (PCR) allow the identification of pathogens and resistances. These methods are used routinely to speed up the analysis of positive blood cultures. The newest PCR based system allows the identification of the 25 most frequent sepsis pathogens by PCR in parallel without previous culture in less than 6 hours. Thereby, these systems might shorten the time of possibly insufficient antiinfective therapy. However, these extensive tools are not suitable as point of care diagnostics. Miniaturization and automating of the nucleic acid based method is pending, as well as an increase of detectable pathogens and resistance genes by these methods. It is assumed that molecular PCR techniques will have an increasing impact on microbiological diagnostics in the future. © Georg Thieme Verlag Stuttgart · New York.
Assessment of neuropsychiatric symptoms in dementia: toward improving accuracy
Stella, Florindo
2013-01-01
The issue of this article concerned the discussion about tools frequently used tools for assessing neuropsychiatric symptoms of patients with dementia, particularly Alzheimer's disease. The aims were to discuss the main tools for evaluating behavioral disturbances, and particularly the accuracy of the Neuropsychiatric Inventory – Clinician Rating Scale (NPI-C). The clinical approach to and diagnosis of neuropsychiatric syndromes in dementia require suitable accuracy. Advances in the recognition and early accurate diagnosis of psychopathological symptoms help guide appropriate pharmacological and non-pharmacological interventions. In addition, recommended standardized and validated measurements contribute to both scientific research and clinical practice. Emotional distress, caregiver burden, and cognitive impairment often experienced by elderly caregivers, may affect the quality of caregiver reports. The clinician rating approach helps attenuate these misinterpretations. In this scenario, the NPI-C is a promising and versatile tool for assessing neuropsychiatric syndromes in dementia, offering good accuracy and high reliability, mainly based on the diagnostic impression of the clinician. This tool can provide both strategies: a comprehensive assessment of neuropsychiatric symptoms in dementia or the investigation of specific psychopathological syndromes such as agitation, depression, anxiety, apathy, sleep disorders, and aberrant motor disorders, among others. PMID:29213846
Doherty, S; Oram, S; Siriwardhana, C; Abas, M
2016-05-01
Trafficking is a global human rights violation with multiple and complex mental health consequences. Valid and reliable mental health assessment tools are needed to inform health-care provision. We reviewed mental health assessment tools used in research with men and women trafficked for sexual and labour exploitation. We searched nine electronic databases (PsycINFO, Ovid Medline, PubMed, Embase, Assia, the Web of Science, Global Health, Google Scholar, and Open Grey) and hand-searched the reference lists of relevant identified studies. Seven studies were included in this Review. Six of the studies screened for post-traumatic stress disorder, depression, and anxiety; one study screened for harmful use or abuse of alcohol and used a diagnostic tool to assess post-traumatic stress disorder, depression, and anxiety. Two studies included men in their sample population. Although the reported prevalence of mental health problems was high, little information was provided about the validity, reliability, and cultural appropriateness of assessment tools. Further research is needed to determine which assessment tools are culturally appropriate, valid, and reliable for trafficked people. Copyright © 2016 Elsevier Ltd. All rights reserved.
Diagnostic Tools for Acute Anterior Cruciate Ligament Injury: GNRB, Lachman Test, and Telos.
Ryu, Seung Min; Na, Ho Dong; Shon, Oog Jin
2018-06-01
The purpose of this study is to compare the accuracy of the GNRB arthrometer (Genourob), Lachman test, and Telos device (GmbH) in acute anterior cruciate ligament (ACL) injuries and to evaluate the accuracy of each diagnostic tool according to the length of time from injury to examination. From September 2015 to September 2016, 40 cases of complete ACL rupture were reviewed. We divided the time from injury to examination into three periods of 10 days each and analyzed the diagnostic tools according to the time frame. An analysis of the area under the curve (AUC) of a receiver operating characteristic curve showed that all diagnostic tools were fairly informative. The GNRB showed a higher AUC than other diagnostic tools. In 10 cases assessed within 10 days after injury, the GNRB showed statistically significant side-to-side difference in laxity (p<0.001), whereas the Telos test and Lachman test did not show significantly different laxity (p=0.541 and p=0.413, respectively). All diagnostic values of the GNRB were better than other diagnostic tools in acute ACL injuries. The GNRB was more effective in acute ACL injuries examined within 10 days of injury. The GNRB arthrometer can be a useful diagnostic tool for acute ACL injuries.
The Diagnostic Accuracy of the Berg Balance Scale in Predicting Falls.
Park, Seong-Hi; Lee, Young-Shin
2017-11-01
This study aimed to evaluate the predictive validity of the Berg Balance Scale (BBS) as a screening tool for fall risks among those with varied levels of balance. A total of 21 studies reporting predictive validity of the BBS of fall risk were meta-analyzed. With regard to the overall predictive validity of the BBS, the pooled sensitivity and specificity were 0.72 and 0.73, respectively; the accuracy curve area was 0.84. The findings showed statistical heterogeneity among studies. Among the sub-groups, the age group of those younger than 65 years, those with neuromuscular disease, those with 2+ falls, and those with a cutoff point of 45 to 49 showed better sensitivity with statistically less heterogeneity. The empirical evidence indicates that the BBS is a suitable tool to screen for the risk of falls and shows good predictability when used with the appropriate criteria and applied to those with neuromuscular disease.
[Imaging of breast tissues changes--early detection, screening and problem solving].
Wruk, Daniela
2008-04-01
In the industrialised countries breast cancer is the cancer with the highest prevalence and causes the highest rate of cancer deaths among women. In Switzerland alone, about 5000 newly diagnosed cases occur per year. Our three main diagnostic tools in imaging diseases of the breast in the setting of screening, early detection or problem solving are mammography, ultrasound and MRI with intravenous contrast application. The most important imaging technique is mammography, which as only method has shown evidence to be suitable for screening so far. As a major accomplishing imaging tool there is sonography, which in women under 30 years of age is the first method of choice in examination of the breasts. The MRI is able to provide additional information about the perfusion of tissue changes within the breast; because of its low specificity, however, it should cautiously be applied for specific questions.
Kwasa, Judith; Cettomai, Deanna; Lwanya, Edwin; Osiemo, Dennis; Oyaro, Patrick; Birbeck, Gretchen L; Price, Richard W; Bukusi, Elizabeth A; Cohen, Craig R; Meyer, Ana-Claire L
2012-01-01
To conduct a preliminary evaluation of the utility and reliability of a diagnostic tool for HIV-associated dementia (HAD) for use by primary health care workers (HCW) which would be feasible to implement in resource-limited settings. In resource-limited settings, HAD is an indication for anti-retroviral therapy regardless of CD4 T-cell count. Anti-retroviral therapy, the treatment for HAD, is now increasingly available in resource-limited settings. Nonetheless, HAD remains under-diagnosed likely because of limited clinical expertise and availability of diagnostic tests. Thus, a simple diagnostic tool which is practical to implement in resource-limited settings is an urgent need. A convenience sample of 30 HIV-infected outpatients was enrolled in Western Kenya. We assessed the sensitivity and specificity of a diagnostic tool for HAD as administered by a primary HCW. This was compared to an expert clinical assessment which included examination by a physician, neuropsychological testing, and in selected cases, brain imaging. Agreement between HCW and an expert examiner on certain tool components was measured using Kappa statistic. The sample was 57% male, mean age was 38.6 years, mean CD4 T-cell count was 323 cells/µL, and 54% had less than a secondary school education. Six (20%) of the subjects were diagnosed with HAD by expert clinical assessment. The diagnostic tool was 63% sensitive and 67% specific for HAD. Agreement between HCW and expert examiners was poor for many individual items of the diagnostic tool (K = .03-.65). This diagnostic tool had moderate sensitivity and specificity for HAD. However, reliability was poor, suggesting that substantial training and formal evaluations of training adequacy will be critical to enable HCW to reliably administer a brief diagnostic tool for HAD.
Lin, Hongli; Wang, Weisheng; Luo, Jiawei; Yang, Xuedong
2014-12-01
The aim of this study was to develop a personalized training system using the Lung Image Database Consortium (LIDC) and Image Database resource Initiative (IDRI) Database, because collecting, annotating, and marking a large number of appropriate computed tomography (CT) scans, and providing the capability of dynamically selecting suitable training cases based on the performance levels of trainees and the characteristics of cases are critical for developing a efficient training system. A novel approach is proposed to develop a personalized radiology training system for the interpretation of lung nodules in CT scans using the Lung Image Database Consortium (LIDC) and Image Database Resource Initiative (IDRI) database, which provides a Content-Boosted Collaborative Filtering (CBCF) algorithm for predicting the difficulty level of each case of each trainee when selecting suitable cases to meet individual needs, and a diagnostic simulation tool to enable trainees to analyze and diagnose lung nodules with the help of an image processing tool and a nodule retrieval tool. Preliminary evaluation of the system shows that developing a personalized training system for interpretation of lung nodules is needed and useful to enhance the professional skills of trainees. The approach of developing personalized training systems using the LIDC/IDRL database is a feasible solution to the challenges of constructing specific training program in terms of cost and training efficiency. Copyright © 2014 AUR. Published by Elsevier Inc. All rights reserved.
Domenech, Mirian; García, Ernesto
2017-01-01
Streptococcus pneumoniae is a common human pathogen and a major causal agent of life-threatening infections that can either be respiratory or non-respiratory. It is well known that the Helix pomatia (edible snail) agglutinin (HPA) lectin shows specificity for terminal αGalNAc residues present, among other locations, in the Forssman pentasaccharide (αGalNAc1→3βGalNAc1→3αGal1→4βGal1→4βGlc). Based on experiments involving choline-independent mutants and different growth conditions, we propose here that HPA recognizes the αGalNAc terminal residues of the cell wall teichoic and lipoteichoic acids of S. pneumoniae. In addition, experimental evidence showing that pneumococci can be specifically labeled with HPA when growing as planktonic cultures as well as in mixed biofilms of S. pneumoniae and Haemophilus influenzae has been obtained. It should be underlined that pneumococci were HPA-labeled despite of the presence of a capsule. Although some non-pneumococcal species also bind the agglutinin, HPA-binding combined with fluorescence microscopy constitutes a suitable tool for identifying S. pneumoniae and, if used in conjunction with Gram staining and/or other suitable technique like antigen detection, it may potentially facilitate a fast and accurate diagnosis of pneumococcal infections. PMID:28769901
Traumatic Brain Injury Detection Using Electrophysiological Methods
Rapp, Paul E.; Keyser, David O.; Albano, Alfonso; Hernandez, Rene; Gibson, Douglas B.; Zambon, Robert A.; Hairston, W. David; Hughes, John D.; Krystal, Andrew; Nichols, Andrew S.
2015-01-01
Measuring neuronal activity with electrophysiological methods may be useful in detecting neurological dysfunctions, such as mild traumatic brain injury (mTBI). This approach may be particularly valuable for rapid detection in at-risk populations including military service members and athletes. Electrophysiological methods, such as quantitative electroencephalography (qEEG) and recording event-related potentials (ERPs) may be promising; however, the field is nascent and significant controversy exists on the efficacy and accuracy of the approaches as diagnostic tools. For example, the specific measures derived from an electroencephalogram (EEG) that are most suitable as markers of dysfunction have not been clearly established. A study was conducted to summarize and evaluate the statistical rigor of evidence on the overall utility of qEEG as an mTBI detection tool. The analysis evaluated qEEG measures/parameters that may be most suitable as fieldable diagnostic tools, identified other types of EEG measures and analysis methods of promise, recommended specific measures and analysis methods for further development as mTBI detection tools, identified research gaps in the field, and recommended future research and development thrust areas. The qEEG study group formed the following conclusions: (1) Individual qEEG measures provide limited diagnostic utility for mTBI. However, many measures can be important features of qEEG discriminant functions, which do show significant promise as mTBI detection tools. (2) ERPs offer utility in mTBI detection. In fact, evidence indicates that ERPs can identify abnormalities in cases where EEGs alone are non-disclosing. (3) The standard mathematical procedures used in the characterization of mTBI EEGs should be expanded to incorporate newer methods of analysis including non-linear dynamical analysis, complexity measures, analysis of causal interactions, graph theory, and information dynamics. (4) Reports of high specificity in qEEG evaluations of TBI must be interpreted with care. High specificities have been reported in carefully constructed clinical studies in which healthy controls were compared against a carefully selected TBI population. The published literature indicates, however, that similar abnormalities in qEEG measures are observed in other neuropsychiatric disorders. While it may be possible to distinguish a clinical patient from a healthy control participant with this technology, these measures are unlikely to discriminate between, for example, major depressive disorder, bipolar disorder, or TBI. The specificities observed in these clinical studies may well be lost in real world clinical practice. (5) The absence of specificity does not preclude clinical utility. The possibility of use as a longitudinal measure of treatment response remains. However, efficacy as a longitudinal clinical measure does require acceptable test–retest reliability. To date, very few test–retest reliability studies have been published with qEEG data obtained from TBI patients or from healthy controls. This is a particular concern because high variability is a known characteristic of the injured central nervous system. PMID:25698950
Traumatic brain injury detection using electrophysiological methods.
Rapp, Paul E; Keyser, David O; Albano, Alfonso; Hernandez, Rene; Gibson, Douglas B; Zambon, Robert A; Hairston, W David; Hughes, John D; Krystal, Andrew; Nichols, Andrew S
2015-01-01
Measuring neuronal activity with electrophysiological methods may be useful in detecting neurological dysfunctions, such as mild traumatic brain injury (mTBI). This approach may be particularly valuable for rapid detection in at-risk populations including military service members and athletes. Electrophysiological methods, such as quantitative electroencephalography (qEEG) and recording event-related potentials (ERPs) may be promising; however, the field is nascent and significant controversy exists on the efficacy and accuracy of the approaches as diagnostic tools. For example, the specific measures derived from an electroencephalogram (EEG) that are most suitable as markers of dysfunction have not been clearly established. A study was conducted to summarize and evaluate the statistical rigor of evidence on the overall utility of qEEG as an mTBI detection tool. The analysis evaluated qEEG measures/parameters that may be most suitable as fieldable diagnostic tools, identified other types of EEG measures and analysis methods of promise, recommended specific measures and analysis methods for further development as mTBI detection tools, identified research gaps in the field, and recommended future research and development thrust areas. The qEEG study group formed the following conclusions: (1) Individual qEEG measures provide limited diagnostic utility for mTBI. However, many measures can be important features of qEEG discriminant functions, which do show significant promise as mTBI detection tools. (2) ERPs offer utility in mTBI detection. In fact, evidence indicates that ERPs can identify abnormalities in cases where EEGs alone are non-disclosing. (3) The standard mathematical procedures used in the characterization of mTBI EEGs should be expanded to incorporate newer methods of analysis including non-linear dynamical analysis, complexity measures, analysis of causal interactions, graph theory, and information dynamics. (4) Reports of high specificity in qEEG evaluations of TBI must be interpreted with care. High specificities have been reported in carefully constructed clinical studies in which healthy controls were compared against a carefully selected TBI population. The published literature indicates, however, that similar abnormalities in qEEG measures are observed in other neuropsychiatric disorders. While it may be possible to distinguish a clinical patient from a healthy control participant with this technology, these measures are unlikely to discriminate between, for example, major depressive disorder, bipolar disorder, or TBI. The specificities observed in these clinical studies may well be lost in real world clinical practice. (5) The absence of specificity does not preclude clinical utility. The possibility of use as a longitudinal measure of treatment response remains. However, efficacy as a longitudinal clinical measure does require acceptable test-retest reliability. To date, very few test-retest reliability studies have been published with qEEG data obtained from TBI patients or from healthy controls. This is a particular concern because high variability is a known characteristic of the injured central nervous system.
Srivastava, Saurabh K; Ruigrok, Vincent J B; Thompson, Natalie J; Trilling, Anke K; Heck, Albert J R; van Rijn, Cees; Beekwilder, Jules; Jongsma, Maarten A
2013-01-01
The 16 kDa heat shock protein (HSP) is an immuno-dominant antigen, used in diagnosis of infectious Mycobacterium tuberculosis (M.tb.) causing tuberculosis (TB). Its use in serum-based diagnostics is limited, but for the direct identification of M.tb. bacteria in sputum or cultures it may represent a useful tool. Recently, a broad set of twelve 16 kDa specific heavy chain llama antibodies (VHH) has been isolated, and their utility for diagnostic applications was explored. To identify the epitopes recognized by the nine (randomly selected from a set of twelve 16 kDa specific VHH antibodies) distinct VHH antibodies, 14 overlapping linear epitopes (each 20 amino acid long) were characterized using direct and sandwich ELISA techniques. Seven out of 14 epitopes were recognized by 8 out of 9 VHH antibodies. The two highest affinity binders B-F10 and A-23 were found to bind distinct epitopes. Sandwich ELISA and SPR experiments showed that only B-F10 was suitable as secondary antibody with both B-F10 and A-23 as anchoring antibodies. To explain this behavior, the epitopes were matched to the putative 3D structure model. Electrospray ionization time-of-flight mass spectrometry and size exclusion chromatography were used to determine the higher order conformation. A homodimer model best explained the differential immunological reactivity of A-23 and B-F10 against heat-treated M.tb. lysates. The concentrations of secreted antigens of M.tb. in sputum are too low for immunological detection and existing kits are only used for identifying M.tb. in cultures. Here we describe how specific combinations of VHH domains could be used to detect the intracellular HSP antigen. Linked to methods of pre-concentrating M.tb. cells prior to lysis, HSP detection may enable the development of protein-based diagnostics of sputum samples and earlier diagnosis of diseases.
DOE Office of Scientific and Technical Information (OSTI.GOV)
James, Veronica J.; ANU)
An early diagnosis of malignancies correlates directly with a better prognosis. Yet for many malignancies there are no readily available, noninvasive, cost-effective diagnostic tests with patients often presenting too late for effective treatment. This article describes for the first time the use of fiber diffraction patterns of skin or fingernails, using X-ray sources, as a biometric diagnostic method for detecting neoplastic disorders including but not limited to melanoma, breast, colon and prostate cancers. With suitable further development, an early low-cost, totally noninvasive yet reliable diagnostic test could be conducted on a regular basis in local radiology facilities, as a confirmatorymore » test for other diagnostic procedures or as a mass screening test using suitable small angle X-ray beam-lines at synchrotrons.« less
Update on diagnostic value of breath test in gastrointestinal and liver diseases
Siddiqui, Imran; Ahmed, Sibtain; Abid, Shahab
2016-01-01
In the field of gastroenterology, breath tests (BTs) are used intermittently as diagnostic tools that allow indirect, non-invasive and relatively less cumbersome evaluation of several disorders by simply quantifying the appearance in exhaled breath of a metabolite of a specific substrate administered. The aim of this review is to have an insight into the principles, methods of analysis and performance parameters of various hydrogen, methane and carbon BTs which are available for diagnosing gastrointestinal disorders such as Helicobacter pylori infection, small intestinal bacterial overgrowth, and carbohydrate malabsorption. Evaluation of gastric emptying is routinely performed by scintigraphy which is however, difficult to perform and not suitable for children and pregnant women, this review has abridged the 13C-octanoic acid test in comparison to scintigraphy and has emphasized on its working protocol and challenges. A new development such as electronic nose test is also highlighted. Moreover we have also explored the limitations and constraints restraining the wide use of these BT. We conclude that breath testing has an enormous potential to be used as a diagnostic modality. In addition it offers distinct advantages over the traditional invasive methods commonly employed. PMID:27574563
NASA Astrophysics Data System (ADS)
Fook Kong, Tian; Ye, Weijian; Peng, Weng Kung; Wei Hou, Han; Marcos; Preiser, Peter Rainer; Nguyen, Nam-Trung; Han, Jongyoon
2015-06-01
Despite significant advancements over the years, there remains an urgent need for low cost diagnostic approaches that allow for rapid, reliable and sensitive detection of malaria parasites in clinical samples. Our previous work has shown that magnetic resonance relaxometry (MRR) is a potentially highly sensitive tool for malaria diagnosis. A key challenge for making MRR based malaria diagnostics suitable for clinical testing is the fact that MRR baseline fluctuation exists between individuals, making it difficult to detect low level parasitemia. To overcome this problem, it is important to establish the MRR baseline of each individual while having the ability to reliably determine any changes that are caused by the infection of malaria parasite. Here we show that an approach that combines the use of microfluidic cell enrichment with a saponin lysis before MRR detection can overcome these challenges and provide the basis for a highly sensitive and reliable diagnostic approach of malaria parasites. Importantly, as little as 0.0005% of ring stage parasites can be detected reliably, making this ideally suited for the detection of malaria parasites in peripheral blood obtained from patients. The approaches used here are envisaged to provide a new malaria diagnosis solution in the near future.
Claus, C; Bergs, S; Emmrich, N C; Hübschen, J M; Mankertz, A; Liebert, U G
2017-02-01
Although teratogenic rubella virus (RV) causes a vaccine-preventable disease, it is still endemic in several countries worldwide. Thus, there is a constant risk of RV importation into non-endemic areas. RV monitoring, especially during measles and Zika virus outbreaks, requires reliable diagnostic tools. For this study, a TaqMan-based one-step reverse transcription-quantitative PCR (RT-qPCR) assay, with the p90 gene as a novel and so far unexplored target for detection of clade I and II genotypes, was developed and evaluated. Automated nucleic acid extraction was carried out. Performance characteristics of the TaqMan RT-qPCR assay were determined for a RV plasmid standard and RNA extracted from virus-infected cell culture supernatants representing clade I and II genotypes. Diagnostic specificity and sensitivity were validated against other RNA and DNA viruses, relevant for RV diagnostic approaches and for RV-positive clinical samples, respectively. The assay is specific and highly sensitive with a limit of detection as low as five to one copies per reaction or 200 infectious virus particles per ml. The coefficients of variation (CV) were specified as intra- (within one run) and inter- (between different runs) assay variation, and calculated based on the standard deviations for the obtained Ct values of the respective samples. Intra- and inter-assay CV values were low, with a maximum of 3.4% and 2.4%, respectively. The assay was shown to be suitable and specific for the analysis of clinical samples. With p90 as a novel target, the highly sensitive and specific TaqMan assay outlined in this study is suitable for RV diagnosis worldwide.
Manga, Selene; Perales, Rocio; Reaño, Maria; D'Ambrosio, Lia; Migliori, Giovanni Battista; Amicosante, Massimo
2016-11-01
Tuberculosis (TB) continues to cause an outsized burden of morbidity and mortality worldwide, still missing efficient and largely accessible diagnostic tools determining an appropriate control of the disease. Serological tests have the potentially to impact TB diagnosis, in particular in extreme clinical settings. The diagnostic performances of the TB-XT HEMA EXPRESS (HEMA-EXPRESS) immunochromatographic rapid test for active TB diagnosis, based on use of multiple Mycobacterium tuberculosis (MTB) specific antigens, have been evaluated in a large study multicentre TB case-finding study, in populations with different exposure level to TB. A total of 1,386 subjects were enrolled in the six participating centres in Peru: 290 active-TB and 1,096 unaffected subjects. The TB prevalence (overall 20.5%) varied between 4.0% and 41.1% in the different study groups. Overall, the HEMA-EXPRESS test had 30.6% sensitivity (range 3.9-77.9%) and 84.6% specificity (range 51.6-97.3%). A significant inverse correlation between test accuracy (overall 73.5%, range 40.4-96.4%) and TB prevalence in the various study populations was observed (Pearson's r=-0.7985; P=0.05). HEMA-EXPRESS, is rapid and relatively inexpensive test suitable for routine use in TB diagnosis. In low TB prevalence conditions, test performance appears in line with WHO Target Product Profile for TB diagnostics. Performances appear suboptimal in high TB prevalence settings. Appropriate set-up in operative clinical settings has to be considered for novel serological tests for TB diagnosis, particularly for formats suitable for point-of-care use.
Cost-effectiveness modelling in diagnostic imaging: a stepwise approach.
Sailer, Anna M; van Zwam, Wim H; Wildberger, Joachim E; Grutters, Janneke P C
2015-12-01
Diagnostic imaging (DI) is the fastest growing sector in medical expenditures and takes a central role in medical decision-making. The increasing number of various and new imaging technologies induces a growing demand for cost-effectiveness analysis (CEA) in imaging technology assessment. In this article we provide a comprehensive framework of direct and indirect effects that should be considered for CEA in DI, suitable for all imaging modalities. We describe and explain the methodology of decision analytic modelling in six steps aiming to transfer theory of CEA to clinical research by demonstrating key principles of CEA in a practical approach. We thereby provide radiologists with an introduction to the tools necessary to perform and interpret CEA as part of their research and clinical practice. • DI influences medical decision making, affecting both costs and health outcome. • This article provides a comprehensive framework for CEA in DI. • A six-step methodology for conducting and interpreting cost-effectiveness modelling is proposed.
New Perspectives on Biomedical Applications of Iron Oxide Nanoparticles.
Magro, Massimiliano; Baratella, Davide; Bonaiuto, Emanuela; de A Roger, Jessica; Vianello, Fabio
2018-02-12
Iron oxide nanomaterials are considered promising tools for improved therapeutic efficacy and diagnostic applications in biomedicine. Accordingly, engineered iron oxide nanomaterials are increasingly proposed in biomedicine, and the interdisciplinary researches involving physics, chemistry, biology (nanotechnology) and medicine have led to exciting developments in the last decades. The progresses of the development of magnetic nanoparticles with tailored physico-chemical and surface properties produced a variety of clinically relevant applications, spanning from magnetic resonance imaging (MRI), drug delivery, magnetic hyperthermia, to in vitro diagnostics. Notwithstanding the wellknown conventional synthetic procedures and their wide use, along with recent advances in the synthetic methods open the door to new generations of naked iron oxide nanoparticles possessing peculiar surface chemistries, suitable for other competitive biomedical applications. New abilities to rationally manipulate iron oxides and their physical, chemical, and biological properties, allow the emersion of additional possibilities for designing novel nanomaterials for theranostic applications. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.
Carter, Cristina; Akar-Ghibril, Nicole; Sestokas, Jeff; Dixon, Gabrina; Bradford, Wilhelmina; Ottolini, Mary
2018-03-01
Oral case presentations provide an opportunity for trainees to communicate diagnostic reasoning at the bedside. However, few tools exist to enable faculty to provide effective feedback. We developed a tool to assess diagnostic reasoning and communication during oral case presentations. Published by Elsevier Inc.
Boenzi, Sara; Deodato, Federica; Taurisano, Roberta; Martinelli, Diego; Verrigni, Daniela; Carrozzo, Rosalba; Bertini, Enrico; Pastore, Anna; Dionisi-Vici, Carlo; Johnson, David W
2014-11-01
Two oxysterols, cholestan-3β,5α,6β-triol (C-triol) and 7-ketocholesterol (7-KC), have been recently proposed as diagnostic markers of Niemann-Pick type C (NP-C) disease, representing a potential alternative diagnostic tool to the more invasive and time consuming filipin test in cultured fibroblasts. Usually, the oxysterols are detected and quantified by liquid chromatography-tandem mass spectrometry (LC-MS/MS) method using atmospheric pressure chemical ionization (APCI) or electro-spray-ionization (ESI) sources, after a variety of derivatization procedures to enhance sensitivity. We developed a sensitive LC-MS/MS method to quantify the oxysterols in plasma as dimethylaminobutyrate ester, suitable for ESI analysis. This method, with an easy liquid-phase extraction and a short derivatization procedure, has been validated to demonstrate specificity, linearity, recovery, lowest limit of quantification, accuracy and precision. The assay was linear over a concentration range of 0.5-200ng/mL for C-triol and 1.0-200ng/mL for 7-KC. Intra-day and inter-day coefficients of variation (CV%) were <15% for both metabolites. Receiver operating characteristic analysis estimates that the area under curve was 0.998 for C-triol, and 0.972 for 7-KC, implying a significant discriminatory power for the method in this patient population of both oxysterols. In summary, our method provides a simple, rapid and non-invasive diagnostic tool for the biochemical diagnosis of NP-C disease. Copyright © 2014 Elsevier B.V. All rights reserved.
De Luca, Chiara; Chung Sheun Thai, Jeffrey; Raskovic, Desanka; Cesareo, Eleonora; Caccamo, Daniela; Trukhanov, Arseny
2014-01-01
Growing numbers of “electromagnetic hypersensitive” (EHS) people worldwide self-report severely disabling, multiorgan, non-specific symptoms when exposed to low-dose electromagnetic radiations, often associated with symptoms of multiple chemical sensitivity (MCS) and/or other environmental “sensitivity-related illnesses” (SRI). This cluster of chronic inflammatory disorders still lacks validated pathogenetic mechanism, diagnostic biomarkers, and management guidelines. We hypothesized that SRI, not being merely psychogenic, may share organic determinants of impaired detoxification of common physic-chemical stressors. Based on our previous MCS studies, we tested a panel of 12 metabolic blood redox-related parameters and of selected drug-metabolizing-enzyme gene polymorphisms, on 153 EHS, 147 MCS, and 132 control Italians, confirming MCS altered (P < 0.05–0.0001) glutathione-(GSH), GSH-peroxidase/S-transferase, and catalase erythrocyte activities. We first described comparable—though milder—metabolic pro-oxidant/proinflammatory alterations in EHS with distinctively increased plasma coenzyme-Q10 oxidation ratio. Severe depletion of erythrocyte membrane polyunsaturated fatty acids with increased ω6/ω3 ratio was confirmed in MCS, but not in EHS. We also identified significantly (P = 0.003) altered distribution-versus-control of the CYP2C19∗1/∗2 SNP variants in EHS, and a 9.7-fold increased risk (OR: 95% C.I. = 1.3–74.5) of developing EHS for the haplotype (null)GSTT1 + (null)GSTM1 variants. Altogether, results on MCS and EHS strengthen our proposal to adopt this blood metabolic/genetic biomarkers' panel as suitable diagnostic tool for SRI. PMID:24812443
NASA Technical Reports Server (NTRS)
Stanley, A. G.; Gauthier, M. K.
1977-01-01
A successful diagnostic technique was developed using a scanning electron microscope (SEM) as a precision tool to determine ionization effects in integrated circuits. Previous SEM methods radiated the entire semiconductor chip or major areas. The large area exposure methods do not reveal the exact components which are sensitive to radiation. To locate these sensitive components a new method was developed, which consisted in successively irradiating selected components on the device chip with equal doses of electrons /10 to the 6th rad (Si)/, while the whole device was subjected to representative bias conditions. A suitable device parameter was measured in situ after each successive irradiation with the beam off.
Algorithmic Classification of Five Characteristic Types of Paraphasias.
Fergadiotis, Gerasimos; Gorman, Kyle; Bedrick, Steven
2016-12-01
This study was intended to evaluate a series of algorithms developed to perform automatic classification of paraphasic errors (formal, semantic, mixed, neologistic, and unrelated errors). We analyzed 7,111 paraphasias from the Moss Aphasia Psycholinguistics Project Database (Mirman et al., 2010) and evaluated the classification accuracy of 3 automated tools. First, we used frequency norms from the SUBTLEXus database (Brysbaert & New, 2009) to differentiate nonword errors and real-word productions. Then we implemented a phonological-similarity algorithm to identify phonologically related real-word errors. Last, we assessed the performance of a semantic-similarity criterion that was based on word2vec (Mikolov, Yih, & Zweig, 2013). Overall, the algorithmic classification replicated human scoring for the major categories of paraphasias studied with high accuracy. The tool that was based on the SUBTLEXus frequency norms was more than 97% accurate in making lexicality judgments. The phonological-similarity criterion was approximately 91% accurate, and the overall classification accuracy of the semantic classifier ranged from 86% to 90%. Overall, the results highlight the potential of tools from the field of natural language processing for the development of highly reliable, cost-effective diagnostic tools suitable for collecting high-quality measurement data for research and clinical purposes.
Bredtmann, Christina M; Krücken, Jürgen; Murugaiyan, Jayaseelan; Kuzmina, Tetiana; von Samson-Himmelstjerna, Georg
2017-01-01
Human and animal health is globally affected by a variety of parasitic helminths. The impact of co-infections and development of anthelmintic resistance requires improved diagnostic tools, especially for parasitic nematodes e.g., to identify resistant species or attribute pathological effects to individual species or particular species combinations. In horses, co-infection with cyathostomins is rather a rule than an exception with typically 5 to 15 species (out of more than 40 described) per individual host. In cyathostomins, reliable morphological species differentiation is currently limited to adults and requires highly specialized expertize while precise morphological identification of eggs and early stage larvae is impossible. The situation is further complicated by a questionable validity of some cyathostomins while others might actually represent cryptic species complexes. Several molecular methods using different target sequences were established to overcome these limitations. For adult worms, PCR followed by sequencing of mitochondrial genes or external or internal ribosomal RNA spacers is suitable to genetically confirm morphological identifications. The most commonly used method to differentiate eggs or larvae is the reverse-line-blot hybridization assay. However, both methods suffer from the fact that target sequences are not available for many species or even that GenBank® entries are unreliable regarding the cyathostomin species. Recent advances in proteomic tools for identification of metazoans including insects and nematodes of the genus Trichinella will be evaluated for suitability to diagnose cyathostomins. Future research should focus on the comparative analysis of morphological, molecular and proteomic data from the same cyathostomin specimen to optimize tools for species-specific identification.
Nematode Species Identification—Current Status, Challenges and Future Perspectives for Cyathostomins
Bredtmann, Christina M.; Krücken, Jürgen; Murugaiyan, Jayaseelan; Kuzmina, Tetiana; von Samson-Himmelstjerna, Georg
2017-01-01
Human and animal health is globally affected by a variety of parasitic helminths. The impact of co-infections and development of anthelmintic resistance requires improved diagnostic tools, especially for parasitic nematodes e.g., to identify resistant species or attribute pathological effects to individual species or particular species combinations. In horses, co-infection with cyathostomins is rather a rule than an exception with typically 5 to 15 species (out of more than 40 described) per individual host. In cyathostomins, reliable morphological species differentiation is currently limited to adults and requires highly specialized expertize while precise morphological identification of eggs and early stage larvae is impossible. The situation is further complicated by a questionable validity of some cyathostomins while others might actually represent cryptic species complexes. Several molecular methods using different target sequences were established to overcome these limitations. For adult worms, PCR followed by sequencing of mitochondrial genes or external or internal ribosomal RNA spacers is suitable to genetically confirm morphological identifications. The most commonly used method to differentiate eggs or larvae is the reverse-line-blot hybridization assay. However, both methods suffer from the fact that target sequences are not available for many species or even that GenBank® entries are unreliable regarding the cyathostomin species. Recent advances in proteomic tools for identification of metazoans including insects and nematodes of the genus Trichinella will be evaluated for suitability to diagnose cyathostomins. Future research should focus on the comparative analysis of morphological, molecular and proteomic data from the same cyathostomin specimen to optimize tools for species-specific identification. PMID:28702376
ERIC Educational Resources Information Center
Wade, Ros; Corbett, Mark; Eastwood, Alison
2013-01-01
Assessing the quality of included studies is a vital step in undertaking a systematic review. The recently revised Quality Assessment of Diagnostic Accuracy Studies (QUADAS) tool (QUADAS-2), which is the only validated quality assessment tool for diagnostic accuracy studies, does not include specific criteria for assessing comparative studies. As…
Plasma Diagnostics: Use and Justification in an Industrial Environment
NASA Astrophysics Data System (ADS)
Loewenhardt, Peter
1998-10-01
The usefulness and importance of plasma diagnostics have played a major role in the development of plasma processing tools in the semiconductor industry. As can be seen through marketing materials from semiconductor equipment manufacturers, results from plasma diagnostic equipment can be a powerful tool in selling the technological leadership of tool design. Some diagnostics have long been used for simple process control such as optical emission for endpoint determination, but in recent years more sophisticated and involved diagnostic tools have been utilized in chamber and plasma source development and optimization. It is now common to find an assortment of tools at semiconductor equipment companies such as Langmuir probes, mass spectrometers, spatial optical emission probes, impedance, ion energy and ion flux probes. An outline of how the importance of plasma diagnostics has grown at an equipment manufacturer over the last decade will be given, with examples of significant and useful results obtained. Examples will include the development and optimization of an inductive plasma source, trends and hardware effects on ion energy distributions, mass spectrometry influences on process development and investigations of plasma-wall interactions. Plasma diagnostic focus, in-house development and proliferation in an environment where financial justification requirements are both strong and necessary will be discussed.
21 CFR 660.31 - Suitability of the donor.
Code of Federal Regulations, 2010 CFR
2010-04-01
...) BIOLOGICS ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Reagent Red Blood Cells § 660.31 Suitability of the donor. Donors of peripheral blood for Reagent Red Blood Cells shall meet the...
21 CFR 660.31 - Suitability of the donor.
Code of Federal Regulations, 2012 CFR
2012-04-01
...) BIOLOGICS ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Reagent Red Blood Cells § 660.31 Suitability of the donor. Donors of peripheral blood for Reagent Red Blood Cells shall meet the...
21 CFR 660.31 - Suitability of the donor.
Code of Federal Regulations, 2013 CFR
2013-04-01
...) BIOLOGICS ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Reagent Red Blood Cells § 660.31 Suitability of the donor. Donors of peripheral blood for Reagent Red Blood Cells shall meet the...
21 CFR 660.31 - Suitability of the donor.
Code of Federal Regulations, 2011 CFR
2011-04-01
...) BIOLOGICS ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Reagent Red Blood Cells § 660.31 Suitability of the donor. Donors of peripheral blood for Reagent Red Blood Cells shall meet the...
Analytical tools for identifying bicycle route suitability, coverage, and continuity.
DOT National Transportation Integrated Search
2012-05-01
This report presents new tools created to assess bicycle suitability using geographic information systems (GIS). Bicycle suitability is a rating of how appropriate a roadway is for bicycle travel based on attributes of the roadway, such as vehi...
Identification of facilitators and barriers to residents' use of a clinical reasoning tool.
DiNardo, Deborah; Tilstra, Sarah; McNeil, Melissa; Follansbee, William; Zimmer, Shanta; Farris, Coreen; Barnato, Amber E
2018-03-28
While there is some experimental evidence to support the use of cognitive forcing strategies to reduce diagnostic error in residents, the potential usability of such strategies in the clinical setting has not been explored. We sought to test the effect of a clinical reasoning tool on diagnostic accuracy and to obtain feedback on its usability and acceptability. We conducted a randomized behavioral experiment testing the effect of this tool on diagnostic accuracy on written cases among post-graduate 3 (PGY-3) residents at a single internal medical residency program in 2014. Residents completed written clinical cases in a proctored setting with and without prompts to use the tool. The tool encouraged reflection on concordant and discordant aspects of each case. We used random effects regression to assess the effect of the tool on diagnostic accuracy of the independent case sets, controlling for case complexity. We then conducted audiotaped structured focus group debriefing sessions and reviewed the tapes for facilitators and barriers to use of the tool. Of 51 eligible PGY-3 residents, 34 (67%) participated in the study. The average diagnostic accuracy increased from 52% to 60% with the tool, a difference that just met the test for statistical significance in adjusted analyses (p=0.05). Residents reported that the tool was generally acceptable and understandable but did not recognize its utility for use with simple cases, suggesting the presence of overconfidence bias. A clinical reasoning tool improved residents' diagnostic accuracy on written cases. Overconfidence bias is a potential barrier to its use in the clinical setting.
An ontology-driven, diagnostic modeling system.
Haug, Peter J; Ferraro, Jeffrey P; Holmen, John; Wu, Xinzi; Mynam, Kumar; Ebert, Matthew; Dean, Nathan; Jones, Jason
2013-06-01
To present a system that uses knowledge stored in a medical ontology to automate the development of diagnostic decision support systems. To illustrate its function through an example focused on the development of a tool for diagnosing pneumonia. We developed a system that automates the creation of diagnostic decision-support applications. It relies on a medical ontology to direct the acquisition of clinic data from a clinical data warehouse and uses an automated analytic system to apply a sequence of machine learning algorithms that create applications for diagnostic screening. We refer to this system as the ontology-driven diagnostic modeling system (ODMS). We tested this system using samples of patient data collected in Salt Lake City emergency rooms and stored in Intermountain Healthcare's enterprise data warehouse. The system was used in the preliminary development steps of a tool to identify patients with pneumonia in the emergency department. This tool was compared with a manually created diagnostic tool derived from a curated dataset. The manually created tool is currently in clinical use. The automatically created tool had an area under the receiver operating characteristic curve of 0.920 (95% CI 0.916 to 0.924), compared with 0.944 (95% CI 0.942 to 0.947) for the manually created tool. Initial testing of the ODMS demonstrates promising accuracy for the highly automated results and illustrates the route to model improvement. The use of medical knowledge, embedded in ontologies, to direct the initial development of diagnostic computing systems appears feasible.
Exploring Rating Quality in Rater-Mediated Assessments Using Mokken Scale Analysis
Wind, Stefanie A.; Engelhard, George
2015-01-01
Mokken scale analysis is a probabilistic nonparametric approach that offers statistical and graphical tools for evaluating the quality of social science measurement without placing potentially inappropriate restrictions on the structure of a data set. In particular, Mokken scaling provides a useful method for evaluating important measurement properties, such as invariance, in contexts where response processes are not well understood. Because rater-mediated assessments involve complex interactions among many variables, including assessment contexts, student artifacts, rubrics, individual rater characteristics, and others, rater-assigned scores are suitable candidates for Mokken scale analysis. The purposes of this study are to describe a suite of indices that can be used to explore the psychometric quality of data from rater-mediated assessments and to illustrate the substantive interpretation of Mokken-based statistics and displays in this context. Techniques that are commonly used in polytomous applications of Mokken scaling are adapted for use with rater-mediated assessments, with a focus on the substantive interpretation related to individual raters. Overall, the findings suggest that indices of rater monotonicity, rater scalability, and invariant rater ordering based on Mokken scaling provide diagnostic information at the level of individual raters related to the requirements for invariant measurement. These Mokken-based indices serve as an additional suite of diagnostic tools for exploring the quality of data from rater-mediated assessments that can supplement rating quality indices based on parametric models. PMID:29795883
Bio-analytical applications of mid-infrared spectroscopy using silver halide fiber-optic probes1
NASA Astrophysics Data System (ADS)
Heise, H. M.; Küpper, L.; Butvina, L. N.
2002-10-01
Infrared-spectroscopy has proved to be a powerful method for the study of various biomedical samples, in particular for in-vitro analysis in the clinical laboratory and for non-invasive diagnostics. In general, the analysis of biofluids such as whole blood, urine, microdialysates and bioreactor broth media takes advantage of the fact that a multitude of analytes can be quantified simultaneously and rapidly without the need for reagents. Progress in the quality of infrared silver halide fibers enabled us to construct several flexible fiber-optic probes of different geometries, which are particularly suitable for the measurement of small biosamples. Recent trends show that dry film measurements by mid-infrared spectroscopy could revolutionize analytical tools in the clinical chemistry laboratory, and an example is given. Infrared diagnostic tools show a promising potential for patients, and minimal-invasive blood glucose assays or skin tissue pathology in particular cannot be left out using mid-infrared fiber-based probes. Other applications include the measurement of skin samples including penetration studies of vitamins and constituents of cosmetic cream formulations. A further field is the micro-domain analysis of biopsy samples from bog mummified corpses, and recent results on the chemistry of dermis and hair samples are reported. Another field of application, for which results are reported, is food analysis and bio-reactor monitoring.
Uchiyama, Mayara Klimuk; Toma, Sergio Hiroshi; Rodrigues, Stephen Fernandes; Shimada, Ana Lucia Borges; Loiola, Rodrigo Azevedo; Cervantes Rodríguez, Hernán Joel; Oliveira, Pedro Vitoriano; Luz, Maciel Santos; Rabbani, Said Rahnamaye; Toma, Henrique Eisi; Poliselli Farsky, Sandra Helena; Araki, Koiti
2015-01-01
Fully dispersible, cationic ultrasmall (7 nm diameter) superparamagnetic iron oxide nanoparticles, exhibiting high relaxivity (178 mM−1s−1 in 0.47 T) and no acute or subchronic toxicity in Wistar rats, were studied and their suitability as contrast agents for magnetic resonance imaging and material for development of new diagnostic and treatment tools demonstrated. After intravenous injection (10 mg/kg body weight), they circulated throughout the vascular system causing no microhemorrhage or thrombus, neither inflammatory processes at the mesentery vascular bed and hepatic sinusoids (leukocyte rolling, adhesion, or migration as evaluated by intravital microscopy), but having been spontaneously concentrated in the liver, spleen, and kidneys, they caused strong negative contrast. The nanoparticles are cleared from kidneys and bladder in few days, whereas the complete elimination from liver and spleen occurred only after 4 weeks. Ex vivo studies demonstrated that cationic ultrasmall superparamagnetic iron oxide nanoparticles caused no effects on hepatic and renal enzymes dosage as well as on leukocyte count. In addition, they were readily concentrated in rat thigh by a magnet showing its potential as magnetically targeted carriers of therapeutic and diagnostic agents. Summarizing, cationic ultrasmall superparamagnetic iron oxide nanoparticles are nontoxic and efficient magnetic resonance imaging contrast agents useful as platform for the development of new materials for application in theranostics. PMID:26251595
Mirmazhari-Anwar, Vahid; Sharifi, Kamran; Mirshahi, Ali; Mohri, Mehrdad; Grünberg, Walter
2013-01-01
Subacute rumen acidosis (SARA) is frequently encountered in ruminants on high-concentrate rations and characterized by mild to moderate rumen pH depression. Although the measurement of rumen pH is considered as a gold standard approach to diagnose SARA, rumen fluid collection is conceived as a cumbersome and invasive procedure. In the present study, the suitability of transabdominal ultrasonography to identify structural changes of the rumen mucosa associated with SARA was explored. Five adult rumen canulated bulls previously adjusted to a roughage-based ration were switched in 10-day intervals to rations with increasing concentrate content. Seven rations with a concentrate content ranging from 5% to 95% were fed. The rumen pH and rumen mucosal thickness were measured at the end of each 10-d feeding period. The left flank was divided into 12 acoustic windows and the mean rumen mucosal thickness for each acoustic window determined for each ration. Repeated measure ANOVA and stepwise regression analyses were conducted. Increasing the dietary concentrate content resulted in thickening of rumen mucosa which was most pronounced in the upper part of the ventral rumen sac and the least pronounced in the uppermost and lowermost parts of the rumen. The intersection of a horizontal line going through the costochondral junction and a vertical line coming from the third lumbar vertebra was found to be most suitable to identify animals with rumen pH < 5.5 at 4 h post feeding. We conclude that transabdominal ultrasonography of the rumen mucosa has the potential to be a suitable, non-invasive diagnostic tool to identify adult ruminants with SARA.
Glycoprofiling of cancer biomarkers: Label-free electrochemical lectin-based biosensors
Pihíková, Dominika; Kasák, Peter
2016-01-01
Glycosylation of biomolecules is one of the most prevalent post- and co-translational modification in a human body, with more than half of all human proteins being glycosylated. Malignant transformation of cells influences glycosylation machinery resulting in subtle changes of the glycosylation pattern within the cell populations as a result of cancer. Thus, an altered terminal glycan motif on glycoproteins could provide a warning signal about disease development and progression and could be applied as a reliable biomarker in cancer diagnostics. Among all highly effective glycoprofiling tools, label-free electrochemical impedance spectroscopy (EIS)-based biosensors have emerged as especially suitable tool for point-of-care early-stage cancer detection. Herein, we highlight the current challenges in glycoprofiling of various cancer biomarkers by ultrasensitive impedimetric-based biosensors with low sample consumption, low cost fabrication and simple miniaturization. Additionally, this review provides a short introduction to the field of glycomics and lectinomics and gives a brief overview of glycan alterations in different types of cancer. PMID:27275016
Shinchi, Hiroyuki; Yuki, Nobuhiro; Ishida, Hideharu; Hirata, Koichi; Wakao, Masahiro; Suda, Yasuo
2015-01-01
Sugar chain binding antibodies have gained substantial attention as biomarkers due to their crucial roles in various disorders. In this study, we developed simple and quick detection method of anti-sugar chain antibodies in sera using our previously developed sugar chain-immobilized fluorescent nanoparticles (SFNPs) for the point-of-care diagnostics. Sugar chain structure on SFNPs was modified with the sugar moieties of the GM1 ganglioside via our original linker molecule to detect anti-GM1 antibodies. The structures and densities of the sugar moieties immobilized on the nanoparticles were evaluated in detail using lectins and sera containing anti-GM1 antibodies from patients with Guillain-Barré syndrome, a neurological disorder, as an example of disease involving anti-sugar chain antibodies. When optimized SFNPs were added to sera from patients with Guillain-Barré syndrome, fluorescent aggregates were able to visually detect under UV light in three hours. The sensitivity of the detection method was equivalent to that of the current ELISA method used for the diagnosis of Guillain-Barré syndrome. These results suggest that our method using SFNPs is suitable for the point-of-care diagnostics of diseases involving anti-sugar chain antibodies.
NASA Technical Reports Server (NTRS)
Eldridge, Jeffrey I.; Bencic, Timothy J.; Zhu, Dongming; Cuy, Michael D.; Wolfe, Douglas E.; Allison, Stephen W.; Beshears, David L.; Jenkins, Thomas P.; Heeg, Bauke; Howard, Robert P.;
2014-01-01
The overall goal of the Aeronautics Research Mission Directorate (ARMD) Seedling Phase II effort was to build on the promising temperature-sensing characteristics of the ultrabright thermographic phosphor Cr-doped gadolinium aluminum perovskite (Cr:GAP) demonstrated in Phase I by transitioning towards an engine environment implementation. The strategy adopted was to take advantage of the unprecedented retention of ultra-bright luminescence from Cr:GAP at temperatures over 1000 C to enable fast 2D temperature mapping of actual component surfaces as well as to utilize inexpensive low-power laser-diode excitation suitable for on-wing diagnostics. A special emphasis was placed on establishing Cr:GAP luminescence-based surface temperature mapping as a new tool for evaluating engine component surface cooling effectiveness.
Affinity-based biosensors as promising tools for gene doping detection.
Minunni, Maria; Scarano, Simona; Mascini, Marco
2008-05-01
Innovative bioanalytical approaches can be foreseen as interesting means for solving relevant emerging problems in anti-doping control. Sport authorities fear that the newer form of doping, so-called gene doping, based on a misuse of gene therapy, will be undetectable and thus much less preventable. The World Anti-Doping Agency has already asked scientists to assist in finding ways to prevent and detect this newest kind of doping. In this Opinion article we discuss the main aspects of gene doping, from the putative target analytes to suitable sampling strategies. Moreover, we discuss the potential application of affinity sensing in this field, which so far has been successfully applied to a variety of analytical problems, from clinical diagnostics to food and environmental analysis.
Miniature Biometric Sensor Project
NASA Technical Reports Server (NTRS)
Falker, John; Terrier, Douglas; Clayton, Ronald; Hanson, Andrea; Cooper, Tommy; Downs, Meghan; Flint, Stephanie; Reyna, Baraquiel; Simon, Cory; Wilt, Grier
2015-01-01
Heart rate monitoring (HRM) is a critical need during exploration missions. Unlike the four separate systems used on ISS today, the single HRM system should perform as a diagnostic tool, perform well during exercise or high level activity, and be suitable for use during EVA. Currently available HRM technologies are dependent on uninterrupted contact with the skin and are prone to data drop-out and motion artifact when worn in the spacesuit or during exercise. Here, we seek an alternative to the chest strap and electrode based sensors currently in use on ISS today. This project aims to develop a single, high performance, robust biosensor with focused efforts on improved heart rate data quality collection during high intensity activity such as exercise or EVA.
Rice, Danielle B; Kloda, Lorie A; Shrier, Ian; Thombs, Brett D
2016-08-01
Meta-analyses that are conducted rigorously and reported completely and transparently can provide accurate evidence to inform the best possible healthcare decisions. Guideline makers have raised concerns about the utility of existing evidence on the diagnostic accuracy of depression screening tools. The objective of our study was to evaluate the transparency and completeness of reporting in meta-analyses of the diagnostic accuracy of depression screening tools using the PRISMA tool adapted for diagnostic test accuracy meta-analyses. We searched MEDLINE and PsycINFO from January 1, 2005 through March 13, 2016 for recent meta-analyses in any language on the diagnostic accuracy of depression screening tools. Two reviewers independently assessed the transparency in reporting using the PRISMA tool with appropriate adaptations made for studies of diagnostic test accuracy. We identified 21 eligible meta-analyses. Twelve of 21 meta-analyses complied with at least 50% of adapted PRISMA items. Of 30 adapted PRISMA items, 11 were fulfilled by ≥80% of included meta-analyses, 3 by 50-79% of meta-analyses, 7 by 25-45% of meta-analyses, and 9 by <25%. On average, post-PRISMA meta-analyses complied with 17 of 30 items compared to 13 of 30 items pre-PRISMA. Deficiencies in the transparency of reporting in meta-analyses of the diagnostic test accuracy of depression screening tools of meta-analyses were identified. Authors, reviewers, and editors should adhere to the PRISMA statement to improve the reporting of meta-analyses of the diagnostic accuracy of depression screening tools. Copyright © 2016 Elsevier Inc. All rights reserved.
2005-08-01
present study, who was previously misdiagnosed with BPH and inflammation, eventually has revealed the prostate cancer with the Gleason score 7. Therefore...Noninvasive Diagnostic and Prognostic Tool for Prostate Cancer ...5a. CONTRACT NUMBER Urine Cells as a Noninvasive Diagnostic and Prognostic Tool for Prostate Cancer 5b. GRANT NUMBER W81XWH-04-1-0774 5c
Analysis of laparoscopy in trauma.
Villavicencio, R T; Aucar, J A
1999-07-01
The optimum roles for laparoscopy in trauma have yet to be established. To date, reviews of laparoscopy in trauma have been primarily descriptive rather than analytic. This article analyzes the results of laparoscopy in trauma. Outcome analysis was done by reviewing 37 studies with more than 1,900 trauma patients, and laparoscopy was analyzed as a screening, diagnostic, or therapeutic tool. Laparoscopy was regarded as a screening tool if it was used to detect or exclude a positive finding (eg, hemoperitoneum, organ injury, gastrointestinal spillage, peritoneal penetration) that required operative exploration or repair. Laparoscopy was regarded as a diagnostic tool when it was used to identify all injuries, rather than as a screening tool to identify the first indication for a laparotomy. It was regarded as a diagnostic tool only in studies that mandated a laparotomy (gold standard) after laparoscopy to confirm the diagnostic accuracy of laparoscopic findings. Costs and charges for using laparoscopy in trauma were analyzed when feasible. As a screening tool, laparoscopy missed 1% of injuries and helped prevent 63% of patients from having a trauma laparotomy. When used as a diagnostic tool, laparoscopy had a 41% to 77% missed injury rate per patient. Overall, laparoscopy carried a 1% procedure-related complication rate. Cost-effectiveness has not been uniformly proved in studies comparing laparoscopy and laparotomy. Laparoscopy has been applied safely and effectively as a screening tool in stable patients with acute trauma. Because of the large number of missed injuries when used as a diagnostic tool, its value in this context is limited. Laparoscopy has been reported infrequently as a therapeutic tool in selected patients, and its use in this context requires further study.
Evaluating online diagnostic decision support tools for the clinical setting.
Pryor, Marie; White, David; Potter, Bronwyn; Traill, Roger
2012-01-01
Clinical decision support tools available at the point of care are an effective adjunct to support clinicians to make clinical decisions and improve patient outcomes. We developed a methodology and applied it to evaluate commercially available online clinical diagnostic decision support (DDS) tools for use at the point of care. We identified 11 commercially available DDS tools and assessed these against an evaluation instrument that included 6 categories; general information, content, quality control, search, clinical results and other features. We developed diagnostically challenging clinical case scenarios based on real patient experience that were commonly missed by junior medical staff. The evaluation was divided into 2 phases; an initial evaluation of all identified and accessible DDS tools conducted by the Clinical Information Access Portal (CIAP) team and a second phase that further assessed the top 3 tools identified in the initial evaluation phase. An evaluation panel consisting of senior and junior medical clinicians from NSW Health conducted the second phase. Of the eleven tools that were assessed against the evaluation instrument only 4 tools completely met the DDS definition that was adopted for this evaluation and were able to produce a differential diagnosis. From the initial phase of the evaluation 4 DDS tools scored 70% or more (maximum score 96%) for the content category, 8 tools scored 65% or more (maximum 100%) for the quality control category, 5 tools scored 65% or more (maximum 94%) for the search category, and 4 tools score 70% or more (maximum 81%) for the clinical results category. The second phase of the evaluation was focused on assessing diagnostic accuracy for the top 3 tools identified in the initial phase. Best Practice ranked highest overall against the 6 clinical case scenarios used. Overall the differentiating factor between the top 3 DDS tools was determined by diagnostic accuracy ranking, ease of use and the confidence and credibility of the clinical information. The evaluation methodology used here to assess the quality and comprehensiveness of clinical DDS tools was effective in identifying the most appropriate tool for the clinical setting. The use of clinical case scenarios is fundamental in determining the diagnostic accuracy and usability of the tools.
A New Spin on an Old Technology: Piezoelectric Ejecta Diagnostics for Shock Environments
NASA Astrophysics Data System (ADS)
Vogan, W. S.; Anderson, W. W.; Grover, M.; King, N. S. P.; Lamoreaux, S. K.; Morley, K. B.; Rigg, P. A.; Stevens, G. D.; Turley, W. D.; Buttler, W. T.
2006-07-01
In our investigation of ejecta, or metal particulate emitted from a surface subjected to shock-loaded conditions, we have developed a shock experiment suitable for testing new ideas in piezoelectric mass and impact detectors. High-explosive (HE) shock loading of tin targets subjected to various machined and compressed finishes results in significant trends in ejecta characteristics of interest such as areal density and velocity. Our enhanced piezoelectric diagnostic, "piezo-pins" modified for shock mitigation, have proven levels of robustness and reliability suitable for effective operation in these ejecta milieux. These field tests address questions about ejecta production from surfaces of interest; experimental results are discussed and compared with those from complementary diagnostics such as x-ray and optical attenuation visualization techniques.
Suitability of the echo-time-shift method as laboratory standard for thermal ultrasound dosimetry
NASA Astrophysics Data System (ADS)
Fuhrmann, Tina; Georg, Olga; Haller, Julian; Jenderka, Klaus-Vitold
2017-03-01
Ultrasound therapy is a promising, non-invasive application with potential to significantly improve cancer therapies like surgery, viro- or immunotherapy. This therapy needs faster, cheaper and more easy-to-handle quality assurance tools for therapy devices as well as possibilities to verify treatment plans and for dosimetry. This limits comparability and safety of treatments. Accurate spatial and temporal temperature maps could be used to overcome these shortcomings. In this contribution first results of suitability and accuracy investigations of the echo-time-shift method for two-dimensional temperature mapping during and after sonication are presented. The analysis methods used to calculate time-shifts were a discrete frame-to-frame and a discrete frame-to-base-frame algorithm as well as a sigmoid fit for temperature calculation. In the future accuracy could be significantly enhanced by using continuous methods for time-shift calculation. Further improvements can be achieved by improving filtering algorithms and interpolation of sampled diagnostic ultrasound data. It might be a comparatively accurate, fast and affordable method for laboratory and clinical quality control.
Heydari Zarnagh, Hafez; Ravanshad, Mehrdad; Pourfatollah, Ali Akbar; Rasaee, Mohammad Javad
2015-04-01
Computational tools are reliable alternatives to laborious work in chimeric protein design. In this study, a chimeric antigen was designed using computational techniques for simultaneous detection of anti-HTLV-I and anti-HBV in infected sera. Databases were searched for amino acid sequences of HBV/HLV-I diagnostic antigens. The immunodominant fragments were selected based on propensity scales. The diagnostic antigen was designed using these fragments. Secondary and tertiary structures were predicted and the B-cell epitopes were mapped on the surface of built model. The synthetic DNA coding antigen was sub-cloned into pGS21a expression vector. SDS-PAGE analysis showed that glutathione fused antigen was highly expressed in E. coli BL21 (DE3) cells. The recombinant antigen was purified by nickel affinity chromatography. ELISA results showed that soluble antigen could specifically react with the HTLV-I and HBV infected sera. This specific antigen could be used as suitable agent for antibody-antigen based screening tests and can help clinicians in order to perform quick and precise screening of the HBV and HTLV-I infections.
Daher, Tamas; Tur, Mehmet Kemal; Brobeil, Alexander; Etschmann, Benjamin; Witte, Biruta; Engenhart-Cabillic, Rita; Krombach, Gabriele; Blau, Wolfgang; Grimminger, Friedrich; Seeger, Werner; Klussmann, Jens Peter; Bräuninger, Andreas; Gattenlöhner, Stefan
2018-06-01
In head and neck squamous cell carcinoma (HNSCC), the occurrence of concurrent lung malignancies poses a significant diagnostic challenge because metastatic HNSCC is difficult to discern from second primary lung squamous cell carcinoma (SCC). However, this differentiation is crucial because the recommended treatments for metastatic HNSCC and second primary lung SCC differ profoundly. We analyzed the origin of lung tumors in 32 patients with HNSCC using human papillomavirus (HPV) typing and targeted next generation sequencing of all coding exons of tumor protein 53 (TP53). Lung tumors were clearly identified as HNSCC metastases or second primary tumors in 29 patients, thus revealing that 16 patients had received incorrect diagnoses based on clinical and morphological data alone. The HPV typing and mutation analysis of all TP53 coding exons is a valuable diagnostic tool in patients with HNSCC and concurrent lung SCC, which can help to ensure that patients receive the most suitable treatment. © 2018 Wiley Periodicals, Inc.
2011-07-01
to any penalty for failing to comply with a collection of information if it does not display a currently valid OMB control number. PLEASE DO NOT...these innovative methods with conventional diagnostic tools that are currently used for assessing bioremediation performance. 132 Rula Deeb (510) 596...conventional diagnostic tools that are currently used for assessing bioremediation performance. DEMONSTRATION RESULTS 3-D multi-level systems
Varas, Catalina; Ravit, Marion; Mimoun, Camille; Panel, Pierre; Huchon, Cyrille; Fauconnier, Arnaud
2016-01-01
Objectives Potentially life-threatening gynecological emergencies (G-PLEs) are acute pelvic conditions that may spontaneously evolve into a life-threatening situation, or those for which there is a risk of sequelae or death in the absence of prompt diagnosis and treatment. The objective of this study was to identify the best combination of non-invasive diagnostic tools to ensure an accurate diagnosis and timely response when faced with G-PLEs for patients arriving with acute pelvic pain at the Gynecological Emergency Department (ED). Methods The data on non-invasive diagnostic tools were sourced from the records of patients presenting at the ED of two hospitals in the Parisian suburbs (France) with acute pelvic pain between September 2006 and April 2008. The medical history of the patients was obtained through a standardized questionnaire completed for a prospective observational study, and missing information was completed with data sourced from the medical forms. Diagnostic tool categories were predefined as a collection of signs or symptoms. We analyzed the association of each sign/symptom with G-PLEs using Pearson’s Chi-Square or Fischer’s exact tests. Symptoms and signs associated with G-PLEs (p-value < 0.20) were subjected to logistic regression to evaluate the diagnostic value of each of the predefined diagnostic tools and in various combinations. Results The data of 365 patients with acute pelvic pain were analyzed, of whom 103 were confirmed to have a PLE. We analyzed five diagnostic tools by logistic regression: Triage Process, History-Taking, Physical Examination, Ultrasonography, and Biological Exams. The combination of History-Taking and Ultrasonography had a C-index of 0.83, the highest for a model combining two tools. Conclusions The use of a standardized self-assessment questionnaire for history-taking and focal ultrasound examination were found to be the most successful tool combination for the diagnosis of gynecological emergencies in a Gynecological ED. Additional tools, such as physical examination, do not add substantial diagnostic value. PMID:27583697
Investigating the Effectiveness of Classroom Diagnostic Tools
ERIC Educational Resources Information Center
Schultz, Robert K.
2012-01-01
The primary purposes of the study are to investigate what teachers experience while using the Classroom Diagnostic Tools (CDT) and to relate those experiences to the rate of growth in students' mathematics achievement. The CDT contains three components: an online computer adaptive diagnostic test, interactive web-based student reports, and…
Ares I-X Ground Diagnostic Prototype
NASA Technical Reports Server (NTRS)
Schwabacher, Mark A.; Martin, Rodney Alexander; Waterman, Robert D.; Oostdyk, Rebecca Lynn; Ossenfort, John P.; Matthews, Bryan
2010-01-01
The automation of pre-launch diagnostics for launch vehicles offers three potential benefits: improving safety, reducing cost, and reducing launch delays. The Ares I-X Ground Diagnostic Prototype demonstrated anomaly detection, fault detection, fault isolation, and diagnostics for the Ares I-X first-stage Thrust Vector Control and for the associated ground hydraulics while the vehicle was in the Vehicle Assembly Building at Kennedy Space Center (KSC) and while it was on the launch pad. The prototype combines three existing tools. The first tool, TEAMS (Testability Engineering and Maintenance System), is a model-based tool from Qualtech Systems Inc. for fault isolation and diagnostics. The second tool, SHINE (Spacecraft Health Inference Engine), is a rule-based expert system that was developed at the NASA Jet Propulsion Laboratory. We developed SHINE rules for fault detection and mode identification, and used the outputs of SHINE as inputs to TEAMS. The third tool, IMS (Inductive Monitoring System), is an anomaly detection tool that was developed at NASA Ames Research Center. The three tools were integrated and deployed to KSC, where they were interfaced with live data. This paper describes how the prototype performed during the period of time before the launch, including accuracy and computer resource usage. The paper concludes with some of the lessons that we learned from the experience of developing and deploying the prototype.
Diagnostic Tools for the Systemic Reform of Schools.
ERIC Educational Resources Information Center
Amsler, Mary; Kirsch, Kayla
This paper presents three interrelated diagnostic tools that can be used by school staff as they begin to plan a systemic reform effort. These tools are designed to help educators reflect on their experiences in creating changes in their school and to examine the current barriers to and supports for the change process. The tools help school design…
Baghdadli, A; Russet, F; Mottron, L
2017-07-01
The autism spectrum (AS) is a multifaceted neurodevelopmental variant associated with lifelong challenges. Despite the relevant importance of identifying AS in adults for epidemiological, public health, and quality of life issues, the measurement properties of the tools currently used to screen and diagnose adults without intellectual disabilities (ID) have not been assessed. This systematic review addresses the accuracy, reliability, and validity of the reported AS screening and diagnostic tools used in adults without ID. Electronic databases and bibliographies were searched, and identified papers evaluated against inclusion criteria. The PRISMA statement was used for reporting the review. We evaluated the quality of the papers using the COSMIN Checklist for psychometric data, and QUADAS-2 for diagnostic data. For the COSMIN assessment, evidence was considered to be strong when several methodologically good articles, or one excellent article, reported consistent evidence for or against a measurement property. For the QUADAS ratings, evidence was considered to be "satisfactory" if at least one study was rated with a low risk of bias and low concern about applicability. We included 38 articles comprising 32 studies, five reviews, and one book chapter and assessed nine tools (three diagnostic and six screening, including eight of their short versions). Among screening tools, only AQ-50, AQ-S, and RAADS-R and RAADS-14 were found to provide satisfactory or intermediate values for their psychometric properties, supported by strong or moderate evidence. Nevertheless, risks of bias and concerns on the applicability of these tools limit the evidence on their diagnostic properties. We found that none of the gold standard diagnostic tools used for children had satisfactory measurement properties. There is limited evidence for the measurement properties of the screening and diagnostic tools used for AS adults with a mean normal range of measured intelligence. This may lessen the validity of conclusions and public health decisions on an important fraction of the adult autistic population. This not only justifies further validation studies of screening and diagnostic tools for autistic adults, but also supports the parallel use of self-reported information and clinical expertise with these instruments during the diagnostic process. Copyright © 2017 Elsevier Masson SAS. All rights reserved.
Zamora Perea, Elvira; Balta León, Rosario; Palomino Salcedo, Miriam; Brogdon, William G; Devine, Gregor J
2009-01-01
Background The purpose of this study was to establish whether the "bottle assay", a tool for monitoring insecticide resistance in mosquitoes, can complement and augment the capabilities of the established WHO assay, particularly in resource-poor, logistically challenging environments. Methods Laboratory reared Aedes aegypti and field collected Anopheles darlingi and Anopheles albimanus were used to assess the suitability of locally sourced solvents and formulated insecticides for use with the bottle assay. Using these adapted protocols, the ability of the bottle assay and the WHO assay to discriminate between deltamethrin-resistant Anopheles albimanus populations was compared. The diagnostic dose of deltamethrin that would identify resistance in currently susceptible populations of An. darlingi and Ae. aegypti was defined. The robustness of the bottle assay during a surveillance exercise in the Amazon was assessed. Results The bottle assay (using technical or formulated material) and the WHO assay were equally able to differentiate deltamethrin-resistant and susceptible An. albimanus populations. A diagnostic dose of 10 μg a.i./bottle was identified as the most sensitive discriminating dose for characterizing resistance in An. darlingi and Ae. aegypti. Treated bottles, prepared using locally sourced solvents and insecticide formulations, can be stored for > 14 days and used three times. Bottles can be stored and transported under local conditions and field-assays can be completed in a single evening. Conclusion The flexible and portable nature of the bottle assay and the ready availability of its components make it a potentially robust and useful tool for monitoring insecticide resistance and efficacy in remote areas that require minimal cost tools. PMID:19728871
Diagnosing Chronic Pancreatitis: Comparison and Evaluation of Different Diagnostic Tools.
Issa, Yama; van Santvoort, Hjalmar C; van Dieren, Susan; Besselink, Marc G; Boermeester, Marja A; Ahmed Ali, Usama
2017-10-01
This study aims to compare the M-ANNHEIM, Büchler, and Lüneburg diagnostic tools for chronic pancreatitis (CP). A cross-sectional analysis of the development of CP was performed in a prospectively collected multicenter cohort including 669 patients after a first episode of acute pancreatitis. We compared the individual components of the M-ANNHEIM, Büchler, and Lüneburg tools, the agreement between tools, and estimated diagnostic accuracy using Bayesian latent-class analysis. A total of 669 patients with acute pancreatitis followed-up for a median period of 57 (interquartile range, 42-70) months were included. Chronic pancreatitis was diagnosed in 50 patients (7%), 59 patients (9%), and 61 patients (9%) by the M-ANNHEIM, Lüneburg, and Büchler tools, respectively. The overall agreement between these tools was substantial (κ = 0.75). Differences between the tools regarding the following criteria led to significant changes in the total number of diagnoses of CP: abdominal pain, recurrent pancreatitis, moderate to marked ductal lesions, endocrine and exocrine insufficiency, pancreatic calcifications, and pancreatic pseudocysts. The Büchler tool had the highest sensitivity (94%), followed by the M-ANNHEIM (87%), and finally the Lüneburg tool (81%). Differences between diagnostic tools for CP are mainly attributed to presence of clinical symptoms, endocrine insufficiency, and certain morphological complications.
Defining the Needs for Next Generation Assays for Tuberculosis
Denkinger, Claudia M.; Kik, Sandra V.; Cirillo, Daniela Maria; Casenghi, Martina; Shinnick, Thomas; Weyer, Karin; Gilpin, Chris; Boehme, Catharina C.; Schito, Marco; Kimerling, Michael; Pai, Madhukar
2015-01-01
To accelerate the fight against tuberculosis, major diagnostic challenges need to be addressed urgently. Post-2015 targets are unlikely to be met without the use of novel diagnostics that are more accurate and can be used closer to where patients first seek care in affordable diagnostic algorithms. This article describes the efforts by the stakeholder community that led to the identification of the high-priority diagnostic needs in tuberculosis. Subsequently target product profiles for the high-priority diagnostic needs were developed and reviewed in a World Health Organization (WHO)-led consensus meeting. The high-priority diagnostic needs included (1) a sputum-based replacement test for smear-microscopy; (2) a non-sputum-based biomarker test for all forms of tuberculosis, ideally suitable for use at levels below microscopy centers; (3) a simple, low cost triage test for use by first-contact care providers as a rule-out test, ideally suitable for use by community health workers; and (4) a rapid drug susceptibility test for use at the microscopy center level. The developed target product profiles, along with complimentary work presented in this supplement, will help to facilitate the interaction between the tuberculosis community and the diagnostics industry with the goal to lead the way toward the post-2015 global tuberculosis targets. PMID:25765104
The development of a screening tool to evaluate gross motor function in HIV-infected infants.
Hilburn, Nicole; Potterton, Joanne; Stewart, Aimee; Becker, Piet
2011-12-01
Neurodevelopmental delay or HIV encephalopathy is a stage four disease indicator for paediatric HIV/AIDS according to the World Health Organisation (WHO), and may be used as a criterion for initiation of highly active antiretroviral therapy (HAART). To date, the only means of prevention of this condition is early initiation of HAART. Studies which have been carried out in South African clinics have revealed the high prevalence of this condition. In developing countries, commencement of HAART is based on declining virologic and immunologic status, as standardised neurodevelopmental assessment tools are not widely available. A standardised developmental screening tool which is suitable for use in a developing country is therefore necessary in order to screen for neurodevelopmental delay to allow for further assessment and referral to rehabilitation services, as well as providing an additional assessment criterion for initiation of HAART. The infant gross motor screening test (IGMST) was developed for this purpose. The standardisation sample of the IGMST consisted of 112 HIV-infected infants between six and 18 months of age. Item selection for the IGMST was based on the Gross Motor scale of the Bayley Scales of Infant Development (BSID)-III. Content validity was assessed by a panel of experts using a nominal group technique (NGT; agreement >80%). Concurrent validity (n=60) of the IGMST was carried out against the BSID-III, and agreement was excellent (K=0.85). The diagnostic properties of the IGMST were evaluated and revealed: sensitivity 97.4%, specificity 85.7%, positive predictive value (PPV) 92.7%, and negative predictive value (NPV) 94.7%. Reliability testing (n=30) revealed inter-rater reliability as: r=1, test-retest reliability: r=0.98 and intra-rater reliability: r=0.98. The results indicate that the statistical properties of the IGMST are excellent, and the tool is suitable for use within the paediatric HIV setting.
Simoneau, Gabrielle; Levis, Brooke; Cuijpers, Pim; Ioannidis, John P A; Patten, Scott B; Shrier, Ian; Bombardier, Charles H; de Lima Osório, Flavia; Fann, Jesse R; Gjerdingen, Dwenda; Lamers, Femke; Lotrakul, Manote; Löwe, Bernd; Shaaban, Juwita; Stafford, Lesley; van Weert, Henk C P M; Whooley, Mary A; Wittkampf, Karin A; Yeung, Albert S; Thombs, Brett D; Benedetti, Andrea
2017-11-01
Individual patient data (IPD) meta-analyses are increasingly common in the literature. In the context of estimating the diagnostic accuracy of ordinal or semi-continuous scale tests, sensitivity and specificity are often reported for a given threshold or a small set of thresholds, and a meta-analysis is conducted via a bivariate approach to account for their correlation. When IPD are available, sensitivity and specificity can be pooled for every possible threshold. Our objective was to compare the bivariate approach, which can be applied separately at every threshold, to two multivariate methods: the ordinal multivariate random-effects model and the Poisson correlated gamma-frailty model. Our comparison was empirical, using IPD from 13 studies that evaluated the diagnostic accuracy of the 9-item Patient Health Questionnaire depression screening tool, and included simulations. The empirical comparison showed that the implementation of the two multivariate methods is more laborious in terms of computational time and sensitivity to user-supplied values compared to the bivariate approach. Simulations showed that ignoring the within-study correlation of sensitivity and specificity across thresholds did not worsen inferences with the bivariate approach compared to the Poisson model. The ordinal approach was not suitable for simulations because the model was highly sensitive to user-supplied starting values. We tentatively recommend the bivariate approach rather than more complex multivariate methods for IPD diagnostic accuracy meta-analyses of ordinal scale tests, although the limited type of diagnostic data considered in the simulation study restricts the generalization of our findings. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Utilization of a CRT display light pen in the design of feedback control systems
NASA Technical Reports Server (NTRS)
Thompson, J. G.; Young, K. R.
1972-01-01
A hierarchical structure of the interlinked programs was developed to provide a flexible computer-aided design tool. A graphical input technique and a data structure are considered which provide the capability of entering the control system model description into the computer in block diagram form. An information storage and retrieval system was developed to keep track of the system description, and analysis and simulation results, and to provide them to the correct routines for further manipulation or display. Error analysis and diagnostic capabilities are discussed, and a technique was developed to reduce a transfer function to a set of nested integrals suitable for digital simulation. A general, automated block diagram reduction procedure was set up to prepare the system description for the analysis routines.
Investigations of a bearing fault detector for railroad bearings
NASA Technical Reports Server (NTRS)
Wilson, D. S.; Frarey, J. L.
1975-01-01
The laboratory tests are described which were conducted on new and damaged bearings to determine the feasibility of using high-frequency vibration as a diagnostic tool. A high-frequency band pass filter and demodulator was assembled to permit field measurements of the high-frequency vibrations. Field tests were conducted on an actual truck and on an axle assembly run in a grease test rig. These field tests were directed toward demonstration of the suitability and capabilities of the high-frequency technique for field application. Two specific areas of field application were identified as being cost effective for railroad use. One area is the examination of railroad roller bearings at a derailment site, and the second is as a wayside detector to supplement present hot box detectors for defective roller bearings.
Applications of the thermography in the animal production
NASA Astrophysics Data System (ADS)
Piñeiro, Carlos; Vizcaino, Elena; Morales, Joaquín.; Manso, Alberto; Díaz, Immaculada; Montalvo, Gema
2015-04-01
Infrared thermography is a working technology for over decades, which have been applied mainly in the buildings. We want to move this use to the animal production in order to help us to detect problems of energy efficiency in the facilities preventing, for example, the animal's welfare. In animal production it is necessary to provide a suitable microclimate according to age and production stage of the animals. This microclimate is achieved in the facilities through the environment modification artificially, providing an appropriate comfort for the animals. Many of the problems detected in farms are related to a poor environmental management and control. This is where infrared thermography becomes an essential diagnostic tool to detect failures in the facilities that will be related with health and performance of the animals. The use of this technology in energy audits for buildings, facilities, etc. is becoming more frequent, enabling the technician to easily detect and assess the temperature and energy losses, and it can be used as a support to draft reports and to transmit the situation to the owner in a visual format. In this way, both will be able to decide what improvements are required. Until now, there was not an appropriate technology with affordable prices and easy to manage enough in order to allow the use of the thermography like a routine tool for the diagnostic of these problems, but currently there are some solutions which are starting to appear on the market to meet the requirements needed by the industry.
Håkonsen, Sasja Jul; Pedersen, Preben Ulrich; Bath-Hextall, Fiona; Kirkpatrick, Pamela
2015-05-15
Effective nutritional screening, nutritional care planning and nutritional support are essential in all settings, and there is no doubt that a health service seeking to increase safety and clinical effectiveness must take nutritional care seriously. Screening and early detection of malnutrition is crucial in identifying patients at nutritional risk. There is a high prevalence of malnutrition in hospitalized patients undergoing treatment for colorectal cancer. To synthesize the best available evidence regarding the diagnostic test accuracy of nutritional tools (sensitivity and specificity) used to identify malnutrition (specifically undernutrition) in patients with colorectal cancer (such as the Malnutrition Screening Tool and Nutritional Risk Index) compared to reference tests (such as the Subjective Global Assessment or Patient Generated Subjective Global Assessment). Patients with colorectal cancer requiring either (or all) surgery, chemotherapy and/or radiotherapy in secondary care. Focus of the review: The diagnostic test accuracy of validated assessment tools/instruments (such as the Malnutrition Screening Tool and Nutritional Risk Index) in the diagnosis of malnutrition (specifically under-nutrition) in patients with colorectal cancer, relative to reference tests (Subjective Global Assessment or Patient Generated Subjective Global Assessment). Types of studies: Diagnostic test accuracy studies regardless of study design. Studies published in English, German, Danish, Swedish and Norwegian were considered for inclusion in this review. Databases were searched from their inception to April 2014. Methodological quality was determined using the Quality Assessment of Diagnostic Accuracy Studies checklist. Data was collected using the data extraction form: the Standards for Reporting Studies of Diagnostic Accuracy checklist for the reporting of studies of diagnostic accuracy. The accuracy of diagnostic tests is presented in terms of sensitivity, specificity, positive and negative predictive values. In addition, the positive likelihood ratio (sensitivity/ [1 - specificity]) and negative likelihood ratio (1 - sensitivity)/ specificity), were also calculated and presented in this review to provide information about the likelihood that a given test result would be expected when the target condition is present compared with the likelihood that the same result would be expected when the condition is absent. Not all trials reported true positive, true negative, false positive and false negative rates, therefore these rates were calculated based on the data in the published papers. A two-by-two truth table was reconstructed for each study, and sensitivity, specificity, positive predictive value, negative predictive value positive likelihood ratio and negative likelihood ratio were calculated for each study. A summary receiver operator characteristics curve was constructed to determine the relationship between sensitivity and specificity, and the area under the summary receiver operator characteristics curve which measured the usefulness of a test was calculated. Meta-analysis was not considered appropriate, therefore data was synthesized in a narrative summary. 1. One study evaluated the Malnutrition Screening Tool against the reference standard Patient-Generated Subjective Global Assessment. The sensitivity was 56% and the specificity 84%. The positive likelihood ratio was 3.100, negative likelihood ratio was 0.59, the diagnostic odds ratio (CI 95%) was 5.20 (1.09-24.90) and the Area Under the Curve (AUC) represents only a poor to fair diagnostic test accuracy. A total of two studies evaluated the diagnostic accuracy of Malnutrition Universal Screening Tool (MUST) (index test) compared to both Subjective Global Assessment (SGA) (reference standard) and PG-SGA (reference standard) in patients with colorectal cancer. In MUST vs SGA the sensitivity of the tool was 96%, specificity was 75%, LR+ 3.826, LR- 0.058, diagnostic OR (CI 95%) 66.00 (6.61-659.24) and AUC represented excellent diagnostic accuracy. In MUST vs PG-SGA the sensitivity of the tool was 72%, specificity 48.9%, LR+ 1.382, LR- 0.579, diagnostic OR (CI 95%) 2.39 (0.87-6.58) and AUC indicated that the tool failed as a diagnostic test to identify patients with colorectal cancer at nutritional risk,. The Nutrition Risk Index (NRI) was compared to SGA representing a sensitivity of 95.2%, specificity of 62.5%, LR+ 2.521, LR- 0.087, diagnostic OR (CI 95%) 28.89 (6.93-120.40) and AUC represented good diagnostic accuracy. In regard to NRI vs PG-SGA the sensitivity of the tool was 68%, specificity 64%, LR+ 1.947, LR- 0.487, diagnostic OR (CI 95%) 4.00 (1.23-13.01) and AUC indicated poor diagnostic test accuracy. There are no single, specific tools used to screen or assess the nutritional status of colorectal cancer patients. All tools showed varied diagnostic accuracies when compared to the reference standards SGA and PG-SGA. Hence clinical judgment combined with perhaps the SGA or PG-SGA should play a major role. The PG-SGA offers several advantages over the SGA tool: 1) the patient completes the medical history component, thereby decreasing the amount of time involved; 2) it contains more nutrition impact symptoms, which are important to the patient with cancer; and 3) it has a scoring system that allows patients to be triaged for nutritional intervention. Therefore, the PG-SGA could be used as a nutrition assessment tool as it allows quick identification and prioritization of colorectal cancer patients with malnutrition in combination with other parameters. This systematic review highlights the need for the following: Further studies needs to investigate the diagnostic accuracy of already existing nutritional screening tools in the context of colorectal cancer patients. If new screenings tools are developed, they should be developed and validated in the specific clinical context within the same patient population (colorectal cancer patients). The Joanna Briggs Institute.
Characteristics of a Cognitive Tool That Helps Students Learn Diagnostic Problem Solving
ERIC Educational Resources Information Center
Danielson, Jared A.; Mills, Eric M.; Vermeer, Pamela J.; Preast, Vanessa A.; Young, Karen M.; Christopher, Mary M.; George, Jeanne W.; Wood, R. Darren; Bender, Holly S.
2007-01-01
Three related studies replicated and extended previous work (J.A. Danielson et al. (2003), "Educational Technology Research and Development," 51(3), 63-81) involving the Diagnostic Pathfinder (dP) (previously Problem List Generator [PLG]), a cognitive tool for learning diagnostic problem solving. In studies 1 and 2, groups of 126 and 113…
New methodology to baseline and match AME polysilicon etcher using advanced diagnostic tools
NASA Astrophysics Data System (ADS)
Poppe, James; Shipman, John; Reinhardt, Barbara E.; Roussel, Myriam; Hedgecock, Raymond; Fonda, Arturo
1999-09-01
As process controls tighten in the semiconductor industry, the need to understand the variables that determine system performance become more important. For plasma etch systems, process success depends on the control of key parameters such as: vacuum integrity, pressure, gas flows, and RF power. It is imperative to baseline, monitor, and control these variables. This paper presents an overview of the methods and tools used by Motorola BMC fabrication facility to characterize an Applied Materials polysilicon etcher. Tool performance data obtained from our traditional measurement techniques are limited in their scope and do not provide a complete picture of the ultimate tool performance. Presently the BMC traditional characterization tools provide a snapshot of the static operation of the equipment under test (EUT); however, complete evaluation of the dynamic performance cannot be monitored without the aid of specialized diagnostic equipment. To provide us with a complete system baseline evaluation of the polysilicon etcher, three diagnostic tools were utilized: Lucas Labs Vacuum Diagnostic System, Residual Gas Analyzer, and the ENI Voltage/Impedance Probe. The diagnostic methodology used to baseline and match key parameters of qualified production equipment has had an immense impact on other equipment characterization in the facility. It has resulted in reduced cycle time for new equipment introduction as well.
Validation of a Low-Thrust Mission Design Tool Using Operational Navigation Software
NASA Technical Reports Server (NTRS)
Englander, Jacob A.; Knittel, Jeremy M.; Williams, Ken; Stanbridge, Dale; Ellison, Donald H.
2017-01-01
Design of flight trajectories for missions employing solar electric propulsion requires a suitably high-fidelity design tool. In this work, the Evolutionary Mission Trajectory Generator (EMTG) is presented as a medium-high fidelity design tool that is suitable for mission proposals. EMTG is validated against the high-heritage deep-space navigation tool MIRAGE, demonstrating both the accuracy of EMTG's model and an operational mission design and navigation procedure using both tools. The validation is performed using a benchmark mission to the Jupiter Trojans.
NASA Astrophysics Data System (ADS)
Lawrie, S. R.; Faircloth, D. C.; Smith, J. D.; Sarmento, T. M.; Whitehead, M. O.; Wood, T.; Perkins, M.; Macgregor, J.; Abel, R.
2018-05-01
A vessel for extraction and source plasma analyses is being used for Penning H- ion source development at the Rutherford Appleton Laboratory. A new set of optical elements including an einzel lens has been installed, which transports over 80 mA of H- beam successfully. Simultaneously, a 2X scaled Penning source has been developed to reduce cathode power density. The 2X source is now delivering a 65 mA H- ion beam at 10% duty factor, meeting its design criteria. The long-term viability of the einzel lens and 2X source is now being evaluated, so new diagnostic devices have been installed. A pair of electrostatic deflector plates is used to correct beam misalignment and perform fast chopping, with a voltage rise time of 24 ns. A suite of four quartz crystal microbalances has shown that the cesium flux in the vacuum vessel is only increased by a factor of two, despite the absence of a dedicated cold trap. Finally, an infrared camera has demonstrated good agreement with thermal simulations but has indicated unexpected heating due to beam loss on the downstream electrode. These types of diagnostics are suitable for monitoring all operational ion sources. In addition to experimental campaigns and new diagnostic tools, the high-performance VSim and COMSOL software packages are being used for plasma simulations of two novel ion thrusters for space propulsion applications. In parallel, a VSim framework has been established to include arbitrary temperature and cesium fields to allow the modeling of surface physics in H- ion sources.
Real-time teleophthalmology versus face-to-face consultation: A systematic review.
Tan, Irene J; Dobson, Lucy P; Bartnik, Stephen; Muir, Josephine; Turner, Angus W
2017-08-01
Introduction Advances in imaging capabilities and the evolution of real-time teleophthalmology have the potential to provide increased coverage to areas with limited ophthalmology services. However, there is limited research assessing the diagnostic accuracy of face-to-face teleophthalmology consultation. This systematic review aims to determine if real-time teleophthalmology provides comparable accuracy to face-to-face consultation for the diagnosis of common eye health conditions. Methods A search of PubMed, Embase, Medline and Cochrane databases and manual citation review was conducted on 6 February and 7 April 2016. Included studies involved real-time telemedicine in the field of ophthalmology or optometry, and assessed diagnostic accuracy against gold-standard face-to-face consultation. The revised quality assessment of diagnostic accuracy studies (QUADAS-2) tool assessed risk of bias. Results Twelve studies were included, with participants ranging from four to 89 years old. A broad number of conditions were assessed and include corneal and retinal pathologies, strabismus, oculoplastics and post-operative review. Quality assessment identified a high or unclear risk of bias in patient selection (75%) due to an undisclosed recruitment processes. The index test showed high risk of bias in the included studies, due to the varied interpretation and conduct of real-time teleophthalmology methods. Reference standard risk was overall low (75%), as was the risk due to flow and timing (75%). Conclusion In terms of diagnostic accuracy, real-time teleophthalmology was considered superior to face-to-face consultation in one study and comparable in six studies. Store-and-forward image transmission coupled with real-time videoconferencing is a suitable alternative to overcome poor internet transmission speeds.
Clinical bacteriology in low-resource settings: today's solutions.
Ombelet, Sien; Ronat, Jean-Baptiste; Walsh, Timothy; Yansouni, Cedric P; Cox, Janneke; Vlieghe, Erika; Martiny, Delphine; Semret, Makeda; Vandenberg, Olivier; Jacobs, Jan
2018-03-05
Low-resource settings are disproportionately burdened by infectious diseases and antimicrobial resistance. Good quality clinical bacteriology through a well functioning reference laboratory network is necessary for effective resistance control, but low-resource settings face infrastructural, technical, and behavioural challenges in the implementation of clinical bacteriology. In this Personal View, we explore what constitutes successful implementation of clinical bacteriology in low-resource settings and describe a framework for implementation that is suitable for general referral hospitals in low-income and middle-income countries with a moderate infrastructure. Most microbiological techniques and equipment are not developed for the specific needs of such settings. Pending the arrival of a new generation diagnostics for these settings, we suggest focus on improving, adapting, and implementing conventional, culture-based techniques. Priorities in low-resource settings include harmonised, quality assured, and tropicalised equipment, consumables, and techniques, and rationalised bacterial identification and testing for antimicrobial resistance. Diagnostics should be integrated into clinical care and patient management; clinically relevant specimens must be appropriately selected and prioritised. Open-access training materials and information management tools should be developed. Also important is the need for onsite validation and field adoption of diagnostics in low-resource settings, with considerable shortening of the time between development and implementation of diagnostics. We argue that the implementation of clinical bacteriology in low-resource settings improves patient management, provides valuable surveillance for local antibiotic treatment guidelines and national policies, and supports containment of antimicrobial resistance and the prevention and control of hospital-acquired infections. Copyright © 2018 Elsevier Ltd. All rights reserved.
Advances in the diagnosis of premenstrual syndrome and premenstrual dysphoric disorder.
Futterman, Lori A
2010-01-01
Premenstrual disorders negatively impact the quality of life and functional ability of millions of women. The two generally recognized premenstrual disorders are premenstrual syndrome (PMS) and premenstrual dysphoric disorder (PMDD). These disorders are characterized by a wide variety of nonspecific mood, somatic and behavioral symptoms that occur only during the late luteal phase of a woman's cycle and disappear soon after the onset of menstruation. This paper reviews the diagnostic criteria for PMS and PMDD, describes some of the more common symptom diaries and other tools used to diagnose premenstrual disorders, and discusses the challenges inherent in diagnosing PMS and PMDD. A survey of peer-reviewed articles and relevant texts provided diagnostic criteria, descriptions of diagnostic tools and information about diagnostic challenges. The many nonspecific symptoms associated with premenstrual disorders complicate the diagnostic process. The use of proven symptom diaries and other diagnostic tools should aid in the differential diagnosis of premenstrual disorders. Patients need to report bothersome premenstrual symptoms, and clinicians should become more proficient in the diagnostic process in order to prevent underdiagnosis of these disorders.
Software Users Manual (SUM): Extended Testability Analysis (ETA) Tool
NASA Technical Reports Server (NTRS)
Maul, William A.; Fulton, Christopher E.
2011-01-01
This software user manual describes the implementation and use the Extended Testability Analysis (ETA) Tool. The ETA Tool is a software program that augments the analysis and reporting capabilities of a commercial-off-the-shelf (COTS) testability analysis software package called the Testability Engineering And Maintenance System (TEAMS) Designer. An initial diagnostic assessment is performed by the TEAMS Designer software using a qualitative, directed-graph model of the system being analyzed. The ETA Tool utilizes system design information captured within the diagnostic model and testability analysis output from the TEAMS Designer software to create a series of six reports for various system engineering needs. The ETA Tool allows the user to perform additional studies on the testability analysis results by determining the detection sensitivity to the loss of certain sensors or tests. The ETA Tool was developed to support design and development of the NASA Ares I Crew Launch Vehicle. The diagnostic analysis provided by the ETA Tool was proven to be valuable system engineering output that provided consistency in the verification of system engineering requirements. This software user manual provides a description of each output report generated by the ETA Tool. The manual also describes the example diagnostic model and supporting documentation - also provided with the ETA Tool software release package - that were used to generate the reports presented in the manual
Yoon, Jung-Ro; Yang, Se-Hyun; Shin, Young-Soo
2018-06-01
Many studies have found associations between laboratory biomarkers and periprosthetic joint infection (PJI), but it remains unclear whether these biomarkers are clinically useful in ruling out PJI. This meta-analysis compared the performance of interleukin-6 (IL-6) versus procalcitonin (PCT) for the diagnosis of PJI. In this meta-analysis, we reviewed studies that evaluated IL-6 or/and PCT as a diagnostic biomarker for PJI and provided sufficient data to permit sensitivity and specificity analyses for each test. The major databases MEDLINE, EMBASE, the Cochrane Library, Web of Science, and SCOPUS were searched for appropriate studies from the earliest available date of indexing through February 28, 2017. No restrictions were placed on language of publication. We identified 18 studies encompassing a total of 1,835 subjects; 16 studies reported on IL-6 and 6 studies reported on PCT. The area under the curve (AUC) was 0.93 (95% CI, 0.91-0.95) for IL-6 and 0.83 (95% CI, 0.79-0.86) for PCT. The pooled sensitivity was 0.83 (95% CI, 0.74-0.89) for IL-6 and 0.58 (95% CI, 0.31-0.81) for PCT. The pooled specificity was 0.91 (95% CI, 0.84-0.95) for IL-6 and 0.95 (95% CI, 0.63-1.00) for PCT. Both the IL-6 and PCT tests had a high positive likelihood ratio (LR); 9.3 (95% CI, 5.3-16.2) and 12.4 (95% CI, 1.7-89.8), respectively, making them excellent rule-in tests for the diagnosis of PJI. The pooled negative LR for IL-6 was 0.19 (95% CI, 0.12-0.29), making it suitable as a rule-out test, whereas the pooled negative LR for PCT was 0.44 (95% CI, 0.25-0.78), making it unsuitable as a rule-out diagnostic tool. Based on the results of the present meta-analysis, IL-6 has higher diagnostic value than PCT for the diagnosis of PJI. Moreover, the specificity of the IL-6 test is higher than its sensitivity. Conversely, PCT is not recommended for use as a rule-out diagnostic tool.
Mugambi, Robert Muriuki; Agola, Eric L; Mwangi, Ibrahim N; Kinyua, Johnson; Shiraho, Esther Andia; Mkoji, Gerald M
2015-11-06
Hookworm infection is a major concern in sub-Saharan Africa, particularly in children and pregnant women. Necator americanus and Ancylostoma duodenale are responsible for this condition. Hookworm disease is one of the Neglected tropical diseases (NTDs) that are targeted for elimination through global mass chemotherapy. To support this there is a need for reliable diagnostic tools. The conventional diagnostic test, Kato-Katz that is based on microscopic detection of parasite ova in faecal samples, is not effective due to its low sensitivity that is brought about mainly by non-random distribution of eggs in stool and day to day variation in egg output. It is tedious, cumbersome to perform and requires experience for correct diagnosis. LAMP-based tests are simple, relatively cheap, offer greater sensitivity, specificity than existing tests, have high throughput capability, and are ideal for use at the point of care. We have developed a LAMP diagnostic test for detection of hookworm infection in faecal samples. LAMP relies on auto cycling strand displacement DNA synthesis performed at isothermal temperature by Bst polymerase and a set of 4 specific primers. The primers used in the LAMP assay were based on the second Internal Transcribed Spacer (ITS-2) region and designed using Primer Explorer version 4 Software. The ITS-2 region of the ribosomal gene (rDNA) was identified as a suitable target due to its low mutation rates and substantial differences between species. DNA was extracted directly from human faecal samples, followed by LAMP amplification at isothermal temperature of 63 °C for 1 h. Amplicons were visualized using gel electrophoresis and SYBR green dye. Both specificity and sensitivity of the assay were determined. The LAMP based technique developed was able to detect N. americanus DNA in faecal samples. The assay showed 100 % specificity and no cross-reaction was observed with other helminth parasites (S. mansoni, A. lumbricoides or T. trichiura). The developed LAMP assay was 97 % sensitive and DNA at concentrations as low as 0.4 fg were amplified. The LAMP assay developed is an appropriate diagnostic method for the detection of N. americanus DNA in human stool samples because of its simplicity, low cost, sensitivity, and specificity. It holds great promise as a useful diagnostic tool for use in disease control where infection intensities have been significantly reduced.
Developing a tool to support diagnostic delivery of dementia.
Bennett, Claire E; De Boos, Danielle; Moghaddam, Nima G
2018-01-01
It is increasingly recognised that there are challenges affecting the current delivery of dementia diagnoses. Steps are required to address this. Current good practice guidelines provide insufficient direction and interventions from other healthcare settings do not appear to fully translate to dementia care settings. This project has taken a sequential two-phase design to developing a tool specific to dementia diagnostic delivery. Interviews with 14 participants explored good diagnostic delivery. Thematic analysis produced key themes (overcoming barriers, navigation of multiple journeys and completing overt and covert tasks) that were used to inform the design of a tool for use by clinicians, patients and companions. The tool was evaluated for acceptability in focused group discussions with 13 participants, which indicated a desire to use the tool and that it could encourage good practice. Adaptations were highlighted and incorporated to improve acceptability. Future research is now required to further evaluate the tool.
Rapid molecular diagnostics for multi-drug resistant tuberculosis in India.
Ramachandran, Rajeswari; Muniyandi, M
2018-03-01
Rapid molecular diagnostic methods help in the detection of TB and Rifampicin resistance. These methods detect TB early, are accurate and play a crucial role in reducing the burden of drug resistant tuberculosis. Areas covered: This review analyses rapid molecular diagnostic tools used in the diagnosis of MDR-TB in India, such as the Line Probe Assay and GeneXpert. We have discussed the burden of MDR-TB and the impact of recent diagnostic tools on case detection and treatment outcomes. This review also discusses the costs involved in establishing these new techniques in India. Expert commentary: Molecular methods have considerable advantages for the programmatic management of drug resistant TB. These include speed, standardization of testing, potentially high throughput and reduced laboratory biosafety requirements. There is a desperate need for India to adopt modern, rapid, molecular tools with point-of-care tests being currently evaluated. New molecular diagnostic tests appear to be cost effective and also help in detecting missing cases. There is enough evidence to support the scaling up of these new tools in India.
Remote consulting based on ultrasonic digital immages and dynamic ultrasonic sequences
NASA Astrophysics Data System (ADS)
Margan, Anamarija; Rustemović, Nadan
2006-03-01
Telematic ultrasonic diagnostics is a relatively new tool in providing health care to patients in remote, islolated communities. Our project facility, "The Virtual Polyclinic - A Specialists' Consulting Network for the Islands", is located on the island of Cres in the Adriatic Sea in Croatia and has been extending telemedical services to the archipelago population since 2000. Telemedicine applications include consulting services by specialists at the University Clinical Hospital Center Rebro in Zagreb and at "Magdalena", a leading cardiology clinic in Croatia. After several years of experience with static high resolution ultrasonic digital immages for referral consulting diagnostics purposes, we now also use dynamic ultrasonic sequences in a project with the Department of Emmergency Gastroenterology at Rebro in Zagreb. The aim of the ongoing project is to compare the advantages and shortcomings in transmitting static ultrasonic digital immages and live sequences of ultrasonic examination in telematic diagnostics. Ultrasonic examination is a dynamic process in which the diagnostic accuracy is highly dependent on the dynamic moment of an ultrasound probe and signal. Our first results indicate that in diffuse parenchymal organ pathology the progression and the follow up of a disease is better presented to a remote consulting specialist by dynamic ultrasound sequences. However, the changes that involve only one part of a parenchymal organ can be suitably presented by static ultrasonic digital images alone. Furthermore, we need less time for digital imaging and such tele-consultations overall are more economical. Our previous telemedicine research and practice proved that we can greatly improve the level of medical care in remote healthcare facilities and cut healthcare costs considerably. The experience in the ongoing project points to a conclusion that we can further optimize remote diagnostics benefits by a right choice of telematic application thus reaching a correct diagnosis and starting an applicable therapy even faster. Nevertheless, a successful implementation of such diagnostics methods may require further improvements in telemedical systems.
Petersen, Tom; Laslett, Mark; Juhl, Carsten
2017-05-12
Clinical examination findings are used in primary care to give an initial diagnosis to patients with low back pain and related leg symptoms. The purpose of this study was to develop best evidence Clinical Diagnostic Rules (CDR] for the identification of the most common patho-anatomical disorders in the lumbar spine; i.e. intervertebral discs, sacroiliac joints, facet joints, bone, muscles, nerve roots, muscles, peripheral nerve tissue, and central nervous system sensitization. A sensitive electronic search strategy using MEDLINE, EMBASE and CINAHL databases was combined with hand searching and citation tracking to identify eligible studies. Criteria for inclusion were: persons with low back pain with or without related leg symptoms, history or physical examination findings suitable for use in primary care, comparison with acceptable reference standards, and statistical reporting permitting calculation of diagnostic value. Quality assessments were made independently by two reviewers using the Quality Assessment of Diagnostic Accuracy Studies tool. Clinical examination findings that were investigated by at least two studies were included and results that met our predefined threshold of positive likelihood ratio ≥ 2 or negative likelihood ratio ≤ 0.5 were considered for the CDR. Sixty-four studies satisfied our eligible criteria. We were able to construct promising CDRs for symptomatic intervertebral disc, sacroiliac joint, spondylolisthesis, disc herniation with nerve root involvement, and spinal stenosis. Single clinical test appear not to be as useful as clusters of tests that are more closely in line with clinical decision making. This is the first comprehensive systematic review of diagnostic accuracy studies that evaluate clinical examination findings for their ability to identify the most common patho-anatomical disorders in the lumbar spine. In some diagnostic categories we have sufficient evidence to recommend a CDR. In others, we have only preliminary evidence that needs testing in future studies. Most findings were tested in secondary or tertiary care. Thus, the accuracy of the findings in a primary care setting has yet to be confirmed.
Saliva as a diagnostic tool for oral and systemic diseases
Javaid, Mohammad A.; Ahmed, Ahad S.; Durand, Robert; Tran, Simon D.
2015-01-01
Early disease detection is not only vital to reduce disease severity and prevent complications, but also critical to increase success rate of therapy. Saliva has been studied extensively as a potential diagnostic tool over the last decade due to its ease and non-invasive accessibility along with its abundance of biomarkers, such as genetic material and proteins. This review will update the clinician on recent advances in salivary biomarkers to diagnose autoimmune diseases (Sjogren's syndrome, cystic fibrosis), cardiovascular diseases, diabetes, HIV, oral cancer, caries and periodontal diseases. Considering their accuracy, efficacy, ease of use and cost effectiveness, salivary diagnostic tests will be available in dental offices. It is expected that the advent of sensitive and specific salivary diagnostic tools and the establishment of defined guidelines and results following rigorous testing will allow salivary diagnostics to be used as chair-side tests for several oral and systemic diseases in the near future. PMID:26937373
Nagamani, S; Gaur, A S; Tanneeru, K; Muneeswaran, G; Madugula, S S; Consortium, Mpds; Druzhilovskiy, D; Poroikov, V V; Sastry, G N
2017-11-01
Molecular property diagnostic suite (MPDS) is a Galaxy-based open source drug discovery and development platform. MPDS web portals are designed for several diseases, such as tuberculosis, diabetes mellitus, and other metabolic disorders, specifically aimed to evaluate and estimate the drug-likeness of a given molecule. MPDS consists of three modules, namely data libraries, data processing, and data analysis tools which are configured and interconnected to assist drug discovery for specific diseases. The data library module encompasses vast information on chemical space, wherein the MPDS compound library comprises 110.31 million unique molecules generated from public domain databases. Every molecule is assigned with a unique ID and card, which provides complete information for the molecule. Some of the modules in the MPDS are specific to the diseases, while others are non-specific. Importantly, a suitably altered protocol can be effectively generated for another disease-specific MPDS web portal by modifying some of the modules. Thus, the MPDS suite of web portals shows great promise to emerge as disease-specific portals of great value, integrating chemoinformatics, bioinformatics, molecular modelling, and structure- and analogue-based drug discovery approaches.
A naked-eye colorimetric "PCR developer"
NASA Astrophysics Data System (ADS)
Valentini, Paola; Pompa, Pier Paolo
2016-04-01
Despite several advances in molecular biology and diagnostics, Polymerase Chain Reaction (PCR) is currently the gold standard for nucleic acids amplification and detection, due to its versatility, low-cost and universality, with estimated <10 billion reactions per year and a worldwide market of several billion dollars/year. Nevertheless, PCR still relies on the laborious, time-consuming, and multi-step gel electrophoresis-based detection, which includes gel casting, electrophoretic run, gel staining, and gel visualization. In this work, we propose a "PCR developer", namely a universal one-step, one-tube method, based on controlled aggregation of gold nanoparticles (AuNPs), to detect PCR products by naked eye in few minutes, with no need for any instrumentation. We demonstrated the specificity and sensitivity of the PCR developer on different model targets, suitable for a qualitative detection in real-world diagnostics (i.e., gene rearrangements, genetically modified organisms, and pathogens). The PCR developer proved to be highly specific and ultra-sensitive, discriminating down to few copies of HIV viral DNA, diluted in an excess of interfering human genomic DNA, which is a clinically relevant viral load. Hence, it could be a valuable tool for both academic research and clinical applications.
Software Tools to Support the Assessment of System Health
NASA Technical Reports Server (NTRS)
Melcher, Kevin J.
2013-01-01
This presentation provides an overview of three software tools that were developed by the NASA Glenn Research Center to support the assessment of system health: the Propulsion Diagnostic Method Evaluation Strategy (ProDIMES), the Systematic Sensor Selection Strategy (S4), and the Extended Testability Analysis (ETA) tool. Originally developed to support specific NASA projects in aeronautics and space, these software tools are currently available to U.S. citizens through the NASA Glenn Software Catalog. The ProDiMES software tool was developed to support a uniform comparison of propulsion gas path diagnostic methods. Methods published in the open literature are typically applied to dissimilar platforms with different levels of complexity. They often address different diagnostic problems and use inconsistent metrics for evaluating performance. As a result, it is difficult to perform a one ]to ]one comparison of the various diagnostic methods. ProDIMES solves this problem by serving as a theme problem to aid in propulsion gas path diagnostic technology development and evaluation. The overall goal is to provide a tool that will serve as an industry standard, and will truly facilitate the development and evaluation of significant Engine Health Management (EHM) capabilities. ProDiMES has been developed under a collaborative project of The Technical Cooperation Program (TTCP) based on feedback provided by individuals within the aircraft engine health management community. The S4 software tool provides a framework that supports the optimal selection of sensors for health management assessments. S4 is structured to accommodate user ]defined applications, diagnostic systems, search techniques, and system requirements/constraints. One or more sensor suites that maximize this performance while meeting other user ]defined system requirements that are presumed to exist. S4 provides a systematic approach for evaluating combinations of sensors to determine the set or sets of sensors that optimally meet the performance goals and the constraints. It identifies optimal sensor suite solutions by utilizing a merit (i.e., cost) function with one of several available optimization approaches. As part of its analysis, S4 can expose fault conditions that are difficult to diagnose due to an incomplete diagnostic philosophy and/or a lack of sensors. S4 was originally developed and applied to liquid rocket engines. It was subsequently used to study the optimized selection of sensors for a simulation ]based aircraft engine diagnostic system. The ETA Tool is a software ]based analysis tool that augments the testability analysis and reporting capabilities of a commercial ]off ]the ]shelf (COTS) package. An initial diagnostic assessment is performed by the COTS software using a user ]developed, qualitative, directed ]graph model of the system being analyzed. The ETA Tool accesses system design information captured within the model and the associated testability analysis output to create a series of six reports for various system engineering needs. These reports are highlighted in the presentation. The ETA Tool was developed by NASA to support the verification of fault management requirements early in the Launch Vehicle process. Due to their early development during the design process, the TEAMS ]based diagnostic model and the ETA Tool were able to positively influence the system design by highlighting gaps in failure detection, fault isolation, and failure recovery.
Asiimwe, Caroline; Kyabayinze, Daniel J; Kyalisiima, Zephaniah; Nabakooza, Jane; Bajabaite, Moses; Counihan, Helen; Tibenderana, James K
2012-01-23
While feasibility of new health technologies in well-resourced healthcare settings is extensively documented, it is largely unknown in low-resourced settings. Uganda's decision to deploy and scale up malaria rapid diagnostic tests (mRDTs) in public health facilities and at the community level provides a useful entry point for documenting field experience, acceptance, and predictive variables for technology acceptance and use. These findings are important in informing implementation of new health technologies, plans, and budgets in low-resourced national disease control programmes. A cross-sectional qualitative descriptive study at 21 health centres in Uganda was undertaken in 2007 to elucidate the barriers and facilitators in the introduction of mRDTs as a new diagnostic technology at lower-level health facilities. Pre-tested interview questionnaires were administered through pre-structured patient exit interviews and semi-structured health worker interviews to gain an understanding of the response to this implementation. A conceptual framework on technology acceptance and use was adapted for this study and used to prepare the questionnaires. Thematic analysis was used to generate themes from the data. A total of 52 of 57 health workers (92%) reported a belief that a positive mRDT result was true, although only 41 of 57 (64%) believed that treatment with anti-malarials was justified for every positive mRDT case. Of the same health workers, only 49% believed that a negative mRDT result was truly negative. Factors linked to these findings were related to mRDT acceptance and use, including the design and characteristics of the device, availability and quality of mRDT ancillary supplies, health worker capacity to investigate febrile cases testing negative with the device and provide appropriate treatment, availability of effective malaria treatments, reliability of the health commodity supply chain, existing national policy recommendations, individual health worker dynamism, and vitality of supervision. mRDTs were found to be acceptable to and used by the target users, provided clear policy guidelines exist, ancillary tools are easy to use and health supplies beyond the diagnostic tools are met. Based on our results, health workers' needs for comprehensive case management should be met, and specific guidance for managing febrile patients with negative test outcomes should be provided alongside the new health technology. The extent, to which the implementation process of mRDT-led, parasite-based diagnosis accommodates end user beliefs, attitudes, perceptions, and satisfaction, as well as technology learnability and suitability, influences the level of acceptance and use of mRDTs. The effectiveness of the health system in providing the enabling environment and the integration of the diagnostic tool into routine service delivery is critical.
ERIC Educational Resources Information Center
Nyachwaya, James M.; Mohamed, Abdi-Rizak; Roehrig, Gillian H.; Wood, Nathan B.; Kern, Anne L.; Schneider, Jamie L.
2011-01-01
Many studies in the chemical education literature report students' alternative conceptions in chemistry and the difficulty they present for future learning. In this paper, we review existing diagnostic tools used to uncover students' alternative conceptions in chemistry and suggest that there are two fundamental issues with such instruments,…
Phytophthora database 2.0: update and future direction.
Park, Bongsoo; Martin, Frank; Geiser, David M; Kim, Hye-Seon; Mansfield, Michele A; Nikolaeva, Ekaterina; Park, Sook-Young; Coffey, Michael D; Russo, Joseph; Kim, Seong H; Balci, Yilmaz; Abad, Gloria; Burgess, Treena; Grünwald, Niklaus J; Cheong, Kyeongchae; Choi, Jaeyoung; Lee, Yong-Hwan; Kang, Seogchan
2013-12-01
The online community resource Phytophthora database (PD) was developed to support accurate and rapid identification of Phytophthora and to help characterize and catalog the diversity and evolutionary relationships within the genus. Since its release in 2008, the sequence database has grown to cover 1 to 12 loci for ≈2,600 isolates (representing 138 described and provisional species). Sequences of multiple mitochondrial loci were added to complement nuclear loci-based phylogenetic analyses and diagnostic tool development. Key characteristics of most newly described and provisional species have been summarized. Other additions to improve the PD functionality include: (i) geographic information system tools that enable users to visualize the geographic origins of chosen isolates on a global-scale map, (ii) a tool for comparing genetic similarity between isolates via microsatellite markers to support population genetic studies, (iii) a comprehensive review of molecular diagnostics tools and relevant references, (iv) sequence alignments used to develop polymerase chain reaction-based diagnostics tools to support their utilization and new diagnostic tool development, and (v) an online community forum for sharing and preserving experience and knowledge accumulated in the global Phytophthora community. Here we present how these improvements can support users and discuss the PD's future direction.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Debono, Josephine C, E-mail: josephine.debono@bci.org.au; Poulos, Ann E; Westmead Breast Cancer Institute, Westmead, New South Wales
The aim of this study was to first evaluate the quality of studies investigating the diagnostic accuracy of radiographers as mammogram screen-readers and then to develop an adapted tool for determining the quality of screen-reading studies. A literature search was used to identify relevant studies and a quality evaluation tool constructed by combining the criteria for quality of Whiting, Rutjes, Dinnes et al. and Brealey and Westwood. This constructed tool was then applied to the studies and subsequently adapted specifically for use in evaluating quality in studies investigating diagnostic accuracy of screen-readers. Eleven studies were identified and the constructed toolmore » applied to evaluate quality. This evaluation resulted in the identification of quality issues with the studies such as potential for bias, applicability of results, study conduct, reporting of the study and observer characteristics. An assessment of the applicability and relevance of the tool for this area of research resulted in adaptations to the criteria and the development of a tool specifically for evaluating diagnostic accuracy in screen-reading. This tool, with further refinement and rigorous validation can make a significant contribution to promoting well-designed studies in this important area of research and practice.« less
A computer-aided ECG diagnostic tool.
Oweis, Rami; Hijazi, Lily
2006-03-01
Jordan lacks companies that provide local medical facilities with products that are of help in daily performed medical procedures. Because of this, the country imports most of these expensive products. Consequently, a local interest in producing such products has emerged and resulted in serious research efforts in this area. The main goal of this paper is to provide local (the north of Jordan) clinics with a computer-aided electrocardiogram (ECG) diagnostic tool in an attempt to reduce time and work demands for busy physicians especially in areas where only one general medicine doctor is employed and a bulk of cases are to be diagnosed. The tool was designed to help in detecting heart defects such as arrhythmias and heart blocks using ECG signal analysis depending on the time-domain representation, the frequency-domain spectrum, and the relationship between them. The application studied here represents a state of the art ECG diagnostic tool that was designed, implemented, and tested in Jordan to serve wide spectrum of population who are from poor families. The results of applying the tool on randomly selected representative sample showed about 99% matching with those results obtained at specialized medical facilities. Costs, ease of interface, and accuracy indicated the usefulness of the tool and its use as an assisting diagnostic tool.
DIAGNOSTIC TOOL DEVELOPMENT AND APPLICATION THROUGH REGIONAL CASE STUDIES
Case studies are a useful vehicle for developing and testing conceptual models, classification systems, diagnostic tools and models, and stressor-response relationships. Furthermore, case studies focused on specific places or issues of interest to the Agency provide an excellent ...
Predicting risk and outcomes for frail older adults: an umbrella review of frailty screening tools
Apóstolo, João; Cooke, Richard; Bobrowicz-Campos, Elzbieta; Santana, Silvina; Marcucci, Maura; Cano, Antonio; Vollenbroek-Hutten, Miriam; Germini, Federico; Holland, Carol
2017-01-01
EXECUTIVE SUMMARY Background A scoping search identified systematic reviews on diagnostic accuracy and predictive ability of frailty measures in older adults. In most cases, research was confined to specific assessment measures related to a specific clinical model. Objectives To summarize the best available evidence from systematic reviews in relation to reliability, validity, diagnostic accuracy and predictive ability of frailty measures in older adults. Inclusion criteria Population Older adults aged 60 years or older recruited from community, primary care, long-term residential care and hospitals. Index test Available frailty measures in older adults. Reference test Cardiovascular Health Study phenotype model, the Canadian Study of Health and Aging cumulative deficit model, Comprehensive Geriatric Assessment or other reference tests. Diagnosis of interest Frailty defined as an age-related state of decreased physiological reserves characterized by an increased risk of poor clinical outcomes. Types of studies Quantitative systematic reviews. Search strategy A three-step search strategy was utilized to find systematic reviews, available in English, published between January 2001 and October 2015. Methodological quality Assessed by two independent reviewers using the Joanna Briggs Institute critical appraisal checklist for systematic reviews and research synthesis. Data extraction Two independent reviewers extracted data using the standardized data extraction tool designed for umbrella reviews. Data synthesis Data were only presented in a narrative form due to the heterogeneity of included reviews. Results Five reviews with a total of 227,381 participants were included in this umbrella review. Two reviews focused on reliability, validity and diagnostic accuracy; two examined predictive ability for adverse health outcomes; and one investigated validity, diagnostic accuracy and predictive ability. In total, 26 questionnaires and brief assessments and eight frailty indicators were analyzed, most of which were applied to community-dwelling older people. The Frailty Index was examined in almost all these dimensions, with the exception of reliability, and its diagnostic and predictive characteristics were shown to be satisfactory. Gait speed showed high sensitivity, but only moderate specificity, and excellent predictive ability for future disability in activities of daily living. The Tilburg Frailty Indicator was shown to be a reliable and valid measure for frailty screening, but its diagnostic accuracy was not evaluated. Screening Letter, Timed-up-and-go test and PRISMA 7 (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) demonstrated high sensitivity and moderate specificity for identifying frailty. In general, low physical activity, variously measured, was one of the most powerful predictors of future decline in activities of daily living. Conclusion Only a few frailty measures seem to be demonstrably valid, reliable and diagnostically accurate, and have good predictive ability. Among them, the Frailty Index and gait speed emerged as the most useful in routine care and community settings. However, none of the included systematic reviews provided responses that met all of our research questions on their own and there is a need for studies that could fill this gap, covering all these issues within the same study. Nevertheless, it was clear that no suitable tool for assessing frailty appropriately in emergency departments was identified. PMID:28398987
TipMT: Identification of PCR-based taxon-specific markers.
Rodrigues-Luiz, Gabriela F; Cardoso, Mariana S; Valdivia, Hugo O; Ayala, Edward V; Gontijo, Célia M F; Rodrigues, Thiago de S; Fujiwara, Ricardo T; Lopes, Robson S; Bartholomeu, Daniella C
2017-02-11
Molecular genetic markers are one of the most informative and widely used genome features in clinical and environmental diagnostic studies. A polymerase chain reaction (PCR)-based molecular marker is very attractive because it is suitable to high throughput automation and confers high specificity. However, the design of taxon-specific primers may be difficult and time consuming due to the need to identify appropriate genomic regions for annealing primers and to evaluate primer specificity. Here, we report the development of a Tool for Identification of Primers for Multiple Taxa (TipMT), which is a web application to search and design primers for genotyping based on genomic data. The tool identifies and targets single sequence repeats (SSR) or orthologous/taxa-specific genes for genotyping using Multiplex PCR. This pipeline was applied to the genomes of four species of Leishmania (L. amazonensis, L. braziliensis, L. infantum and L. major) and validated by PCR using artificial genomic DNA mixtures of the Leishmania species as templates. This experimental validation demonstrates the reliability of TipMT because amplification profiles showed discrimination of genomic DNA samples from Leishmania species. The TipMT web tool allows for large-scale identification and design of taxon-specific primers and is freely available to the scientific community at http://200.131.37.155/tipMT/ .
2014-01-01
Background The Project on a Framework for Rating Evidence in Public Health (PRECEPT) was initiated and is being funded by the European Centre for Disease Prevention and Control (ECDC) to define a methodology for evaluating and grading evidence and strength of recommendations in the field of public health, with emphasis on infectious disease epidemiology, prevention and control. One of the first steps was to review existing quality appraisal tools (QATs) for individual research studies of various designs relevant to this area, using a question-based approach. Methods Through team discussions and expert consultations, we identified 20 relevant types of public health questions, which were grouped into six domains, i.e. characteristics of the pathogen, burden of disease, diagnosis, risk factors, intervention, and implementation of intervention. Previously published systematic reviews were used and supplemented by expert consultation to identify suitable QATs. Finally, a matrix was constructed for matching questions to study designs suitable to address them and respective QATs. Key features of each of the included QATs were then analyzed, in particular in respect to its intended use, types of questions and answers, presence/absence of a quality score, and if a validation was performed. Results In total we identified 21 QATs and 26 study designs, and matched them. Four QATs were suitable for experimental quantitative study designs, eleven for observational quantitative studies, two for qualitative studies, three for economic studies, one for diagnostic test accuracy studies, and one for animal studies. Included QATs consisted of six to 28 items. Six of the QATs had a summary quality score. Fourteen QATs had undergone at least one validation procedure. Conclusions The results of this methodological study can be used as an inventory of potentially relevant questions, appropriate study designs and QATs for researchers and authorities engaged with evidence-based decision-making in infectious disease epidemiology, prevention and control. PMID:24886571
Harder, Thomas; Takla, Anja; Rehfuess, Eva; Sánchez-Vivar, Alex; Matysiak-Klose, Dorothea; Eckmanns, Tim; Krause, Gérard; de Carvalho Gomes, Helena; Jansen, Andreas; Ellis, Simon; Forland, Frode; James, Roberta; Meerpohl, Joerg J; Morgan, Antony; Schünemann, Holger; Zuiderent-Jerak, Teun; Wichmann, Ole
2014-05-21
The Project on a Framework for Rating Evidence in Public Health (PRECEPT) was initiated and is being funded by the European Centre for Disease Prevention and Control (ECDC) to define a methodology for evaluating and grading evidence and strength of recommendations in the field of public health, with emphasis on infectious disease epidemiology, prevention and control. One of the first steps was to review existing quality appraisal tools (QATs) for individual research studies of various designs relevant to this area, using a question-based approach. Through team discussions and expert consultations, we identified 20 relevant types of public health questions, which were grouped into six domains, i.e. characteristics of the pathogen, burden of disease, diagnosis, risk factors, intervention, and implementation of intervention. Previously published systematic reviews were used and supplemented by expert consultation to identify suitable QATs. Finally, a matrix was constructed for matching questions to study designs suitable to address them and respective QATs. Key features of each of the included QATs were then analyzed, in particular in respect to its intended use, types of questions and answers, presence/absence of a quality score, and if a validation was performed. In total we identified 21 QATs and 26 study designs, and matched them. Four QATs were suitable for experimental quantitative study designs, eleven for observational quantitative studies, two for qualitative studies, three for economic studies, one for diagnostic test accuracy studies, and one for animal studies. Included QATs consisted of six to 28 items. Six of the QATs had a summary quality score. Fourteen QATs had undergone at least one validation procedure. The results of this methodological study can be used as an inventory of potentially relevant questions, appropriate study designs and QATs for researchers and authorities engaged with evidence-based decision-making in infectious disease epidemiology, prevention and control.
ERIC Educational Resources Information Center
Eshlaghy, Abbas Toloie; Kaveh, Haydeh
2009-01-01
The purpose of this study was to determine the most suitable ICT-based education and define the most suitable e-content creation tools for quantitative courses in the IT-management Masters program. ICT-based tools and technologies are divided in to three categories: the creation of e-content, the offering of e-content, and access to e-content. In…
Bodjo, Sanne Charles; Baziki, Jean-de-Dieu; Nwankpa, Nick; Chitsungo, Ethel; Koffi, Yao Mathurin; Couacy-Hymann, Emmanuel; Diop, Mariame; Gizaw, Daniel; Tajelser, Idris Badri Adam; Lelenta, Mamadou; Diallo, Adama; Tounkara, Karim
2018-07-01
Peste des petits ruminants (PPR) is a contagious and economically important disease affecting production of small ruminants (i.e., sheep and goats). Taking into consideration the lessons learnt from the Global Rinderpest Eradication Programme (GREP), PPR is now targeted by the international veterinary community as the next animal disease to be eradicated. To support the African continental programme for the control of PPR, the Pan African Veterinary Vaccine Centre of the African Union (AU-PANVAC) is developing diagnostics tools. Here, we describe the development of a blocking enzyme-linked immunosorbent assay (bELISA) that allows testing of a large number of samples for specific detection of antibodies directed against PPR virus in sheep and goat sera. The PPR bELISA uses an anti-haemagglutinin (H) monoclonal antibody (MAb) as a competitor antibody, and tests results are interpreted using the percentage of inhibition (PI) of MAb binding generated by the serum sample. PI values below or equal to 18% (PI ≤ 18%) are negative, PI values greater than or equal to 25% (PI ≥ 25%) are positive, and PI values greater than 18% and below 25% are doubtful. The diagnostic specificity (DSp) and diagnostic sensitivity (DSe) were found to be 100% and 93.74%, respectively. The H-based PPR-bELISA showed good correlation with the virus neutralization test (VNT), the gold standard test, with a kappa value of 0.947. The H-based PPR-bELISA is more specific than the commercial kit ID Screen® PPR Competition (N-based PPR-cELISA) from IDvet (France), but the commercial kit is slightly more sensitive than the H-based PPR-bELISA. The validation process also indicated good repeatability and reproducibility of the H-based PPR-bELISA, making this new test a suitable tool for the surveillance and sero-monitoring of the vaccination campaign.
Serological approaches for the diagnosis of schistosomiasis - A review.
Hinz, Rebecca; Schwarz, Norbert G; Hahn, Andreas; Frickmann, Hagen
2017-02-01
Schistosomiasis is a common disease in endemic areas of Sub-Saharan Africa, South America and Asia. It is rare in Europe, mainly imported from endemic countries due to travelling or human migration. Available methods for the diagnosis of schistosomiasis comprise microscopic, molecular and serological approaches, with the latter detecting antigens or antibodies associated with Schistosoma spp. infection. The serological approach is a valuable screening tool in low-endemicity settings and for travel medicine, though the interpretation of any diagnostic results requires knowledge of test characteristics and a patient's history. Specific antibody detection by most currently used assays is only possible in a relatively late stage of infection and does not allow for the differentiation of acute from previous infections for therapeutic control or the discrimination between persisting infection and re-infection. Throughout the last decades, new target antigens have been identified, and assays with improved performance and suitability for use in the field have been developed. For numerous assays, large-scale studies are still required to reliably characterise assay characteristics alone and in association with other available methods for the diagnosis of schistosomiasis. Apart from S. mansoni, S. haematobium and S. japonicum, for which most available tests were developed, other species of Schistosoma that occur less frequently need to be taken into account. This narrative review describes and critically discusses the results of published studies on the evaluation of serological assays that detect antibodies against different Schistosoma species of humans. It provides insights into the diagnostic performance and an overview of available assays and their suitability for large-scale use or individual diagnosis, and thus sets the scene for serological diagnosis of schistosomiasis and the interpretation of results. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.
Diagnostic Competence of Primary School Mathematics Teachers during Classroom Situations
ERIC Educational Resources Information Center
Hoth, Jessica; Döhrmann, Martina; Kaiser, Gabriele; Busse, Andreas; König, Johannes; Blömeke, Sigrid
2016-01-01
One of the main challenges for teachers during teaching in class is the diagnosis of students' learning and thinking processes. For this purpose, teachers must perceive relevant information, they need to interpret this information and finally, they need to respond and select suitable opportunities to learn. In this paper, diagnostic processes in…
Dosimetry study of diagnostic X-ray using doped iodide normoxic polymer gels
NASA Astrophysics Data System (ADS)
Huang, Y. R.; Chang, Y. J.; Hsieh, L. L.; Liu, M. H.; Liu, J. S.; Chu, C. H.; Hsieh, B. T.
2014-11-01
In radiotherapy, polymer gel dosimeters are used for three-dimensional (3D) dose distribution. However, the doses are within the Gy range. In this study, we attempted to develop a low-dose 3D dosimeter within the mGy range for diagnostic radiology. The effect of the iodinated compound was used as a dose enhancement sensitizer to enhance the dose sensitivity of normoxic polymer gel dosimeters. This study aims to use N-isopropylacrylamide(NIPAM)-based and methacrylic acid (MAGAT)-based gels to evaluate the potential dose enhancement sensitizer, as well as to compare two gels that may be suitable for measuring diagnostic radiation doses. The suitable formulation of NIPAM gel [5% (w/w) gelatin, 5% (w/w) NIPAM, 3% (w/w) N,N‧-methylenebisacrylamide (BIS), 5 mM tetrakis (hydroxymethyl) phosphonium chloride (THPC), and 87% (w/w) deionized distilled water] and MAGAT gel (4% MAA, 9% gelatin, 87% deionized water, and 10 mM THPC) were used and loaded with clinical iodinated contrast medium agent (Iobitridol, Xenetix® 350). Irradiation was conducted using X-ray computed tomography. The irradiation doses ranged from 0 mGy to 80 mGy. Optical computed tomography was the employed gel measurement system. The results indicate that the iodinated contrast agent yields a quantifiable dose enhancement ratio. The dose enhancement ratios of NIPAM and MAGAT gels are 3.35±0.6 and 1.36±0.3, respectively. The developed NIPAM gel in this study could be suitable for measuring diagnostic radiation doses.
Defining the needs for next generation assays for tuberculosis.
Denkinger, Claudia M; Kik, Sandra V; Cirillo, Daniela Maria; Casenghi, Martina; Shinnick, Thomas; Weyer, Karin; Gilpin, Chris; Boehme, Catharina C; Schito, Marco; Kimerling, Michael; Pai, Madhukar
2015-04-01
To accelerate the fight against tuberculosis, major diagnostic challenges need to be addressed urgently. Post-2015 targets are unlikely to be met without the use of novel diagnostics that are more accurate and can be used closer to where patients first seek care in affordable diagnostic algorithms. This article describes the efforts by the stakeholder community that led to the identification of the high-priority diagnostic needs in tuberculosis. Subsequently target product profiles for the high-priority diagnostic needs were developed and reviewed in a World Health Organization (WHO)-led consensus meeting. The high-priority diagnostic needs included (1) a sputum-based replacement test for smear-microscopy; (2) a non-sputum-based biomarker test for all forms of tuberculosis, ideally suitable for use at levels below microscopy centers; (3) a simple, low cost triage test for use by first-contact care providers as a rule-out test, ideally suitable for use by community health workers; and (4) a rapid drug susceptibility test for use at the microscopy center level. The developed target product profiles, along with complimentary work presented in this supplement, will help to facilitate the interaction between the tuberculosis community and the diagnostics industry with the goal to lead the way toward the post-2015 global tuberculosis targets. © The Author 2014. Published by Oxford University Press on behalf of the Infectious Diseases Society of America. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.
Tang, Yin-Liang; Chiu, Chien-Yu; Lin, Chun-Yu; Huang, Chung-Hao; Chen, Yen-Hsu; Destura, Raul V.; Chao, Day-Yu; Wu, Han-Chung
2015-01-01
Dengue virus (DENV) infection is currently at pandemic levels, with populations in tropical and subtropical regions at greatest risk of infection. Early diagnosis and management remain the cornerstone for good clinical outcomes, thus efficient and accurate diagnostic technology in the early stage of the disease is urgently needed. Serotype-specific monoclonal antibodies (mAbs) against the DENV1 nonstructural protein 1 (NS1), DA12-4, DA13-2, and DA15-3, which were recently generated using the hybridoma technique, are suitable for use in diagnostic platforms. Immunofluorescence assay (IFA), enzyme-linked immunosorbent assay (ELISA) and Western blot analysis further confirmed the serotype specificity of these three monoclonal antibodies. The ELISA-based diagnostic platform was established using the combination of two highly sensitive mAbs (DA15-3 and DB20-6). The same combination was also used for the flow cytometry-based diagnostic platform. We report here the detection limits of flow cytometry-based and ELISA-based diagnostic platforms using these mAbs to be 0.1 and 1 ng/mL, respectively. The collected clinical patient serum samples were also assayed by these two serotyping diagnostic platforms. The sensitivity and specificity for detecting NS1 protein of DENV1 are 90% and 96%, respectively. The accuracy of our platform for testing clinical samples is more advanced than that of the two commercial NS1 diagnostic platforms. In conclusion, our platforms are suitable for the early detection of NS1 protein in DENV1 infected patients. PMID:26610481
Peripheral nerve ultrasound scoring systems: benchmarking and comparative analysis.
Grimm, Alexander; Rattay, Tim W; Winter, Natalie; Axer, Hubertus
2017-02-01
Ultrasound of the nerves is an additive diagnostic tool to evaluate polyneuropathy. Recently, the need for standardized scoring systems has widely been discussed; different scores are described so far. Therefore, 327 patients with polyneuropathy were analyzed by ultrasound in our laboratory. Consequently, several ultrasound scoring tools were applied, i.e., the nerve pattern classification according to Padua et al. in all patients with CIDP and variants, the Bochum ultrasound score (BUS) and the neuritis ultrasound protocol in immune-mediated neuritis, the ultrasound pattern sum score, the homogeneity score, and the nerve enlargement distribution score in all neuropathies if possible. For all scores good accuracy was found. Most patients with CIDP revealed hypoechoic enlarged nerves (Class 1), the BUS/NUP was useful to identify GBS (sensitivity >85%), MMN (100%) and CIDP (>70%), while the UPSS showed high sensitivity and positive/negative predictive values (N/PPV) in the diagnosis of GBS (>70%), CIDP (>85%) and axonal non-inflammatory neuropathies (>90%). Homogeneous nerves were found in most CMT1 patients (66.7%), while immune-mediated neuropathies mostly show regional nerve enlargement. The HS was suitable to identify CMT patients with an HS ≥5 points. All scores were easily applicable with high accuracy. The former-reported results could be similarly confirmed. However, all sores have some incompleteness concerning unselected polyneuropathy population, particularly rare and focal types. Scoring systems are useful and easily applicable. They show high accuracy in certain neuropathies, but also offer some gaps and can, therefore, only be used in addition to standard diagnostic routines such as electrophysiology.
Benej, Martin; Bendlova, Bela; Vaclavikova, Eliska; Poturnajova, Martina
2011-10-06
Reliable and effective primary screening of mutation carriers is the key condition for common diagnostic use. The objective of this study is to validate the method high resolution melting (HRM) analysis for routine primary mutation screening and accomplish its optimization, evaluation and validation. Due to their heterozygous nature, germline point mutations of c-RET proto-oncogene, associated to multiple endocrine neoplasia type 2 (MEN2), are suitable for HRM analysis. Early identification of mutation carriers has a major impact on patients' survival due to early onset of medullary thyroid carcinoma (MTC) and resistance to conventional therapy. The authors performed a series of validation assays according to International Conference on Harmonization of Technical Requirements for Registration of Pharmaceuticals for Human Use (ICH) guidelines for validation of analytical procedures, along with appropriate design and optimization experiments. After validated evaluation of HRM, the method was utilized for primary screening of 28 pathogenic c-RET mutations distributed among nine exons of c-RET gene. Validation experiments confirm the repeatability, robustness, accuracy and reproducibility of HRM. All c-RET gene pathogenic variants were detected with no occurrence of false-positive/false-negative results. The data provide basic information about design, establishment and validation of HRM for primary screening of genetic variants in order to distinguish heterozygous point mutation carriers among the wild-type sequence carriers. HRM analysis is a powerful and reliable tool for rapid and cost-effective primary screening, e.g., of c-RET gene germline and/or sporadic mutations and can be used as a first line potential diagnostic tool.
Diagnostic tools in Rhinology EAACI position paper
2011-01-01
This EAACI Task Force document aims at providing the readers with a comprehensive and complete overview of the currently available tools for diagnosis of nasal and sino-nasal disease. We have tried to logically order the different important issues related to history taking, clinical examination and additional investigative tools for evaluation of the severity of sinonasal disease into a consensus document. A panel of European experts in the field of Rhinology has contributed to this consensus document on Diagnostic Tools in Rhinology. PMID:22410181
Propulsion Diagnostic Method Evaluation Strategy (ProDiMES) User's Guide
NASA Technical Reports Server (NTRS)
Simon, Donald L.
2010-01-01
This report is a User's Guide for the Propulsion Diagnostic Method Evaluation Strategy (ProDiMES). ProDiMES is a standard benchmarking problem and a set of evaluation metrics to enable the comparison of candidate aircraft engine gas path diagnostic methods. This Matlab (The Mathworks, Inc.) based software tool enables users to independently develop and evaluate diagnostic methods. Additionally, a set of blind test case data is also distributed as part of the software. This will enable the side-by-side comparison of diagnostic approaches developed by multiple users. The Users Guide describes the various components of ProDiMES, and provides instructions for the installation and operation of the tool.
NASA Astrophysics Data System (ADS)
Brousset, Christine; Baudrillard, Gilles
A neural network tool was developed to automate the Non Destructive Testing (NDT) of aeronautical structures carried out with the SIAM system. The SIAM system is used to reveal splits in longitudinal metal joints on the Airbus fuselage. The integration of the neural net tool within the SIAM control system is considered possible. The automatic diagnostic should provide the operator with an aid which will permit a greater reliability of maintenance control. The diagnostic performed with this tool would be rapid;: the control of 30,000 rivets on the Airbus fuselage would take approximately 45 minutes.
Linear array ultrasonography to stage rectal neoplasias suitable for local treatment.
Ravizza, Davide; Tamayo, Darina; Fiori, Giancarla; Trovato, Cristina; De Roberto, Giuseppe; de Leone, Annalisa; Crosta, Cristiano
2011-08-01
Because of the many therapeutic options available, a reliable staging is crucial for rectal neoplasia management. Adenomas and cancers limited to the submucosa without lymph node involvement may be treated locally. The aim of this study is to evaluate the diagnostic accuracy of endorectal ultrasonography in the staging of neoplasias suitable for local treatment. We considered all patients who underwent endorectal ultrasonography between 2001 and 2010. The study population consisted of 92 patients with 92 neoplasias (68 adenocarcinomas and 24 adenomas). A 5 and 7.5MHz linear array echoendoscope was used. The postoperative histopathologic result was compared with the preoperative staging defined by endorectal ultrasonography. Adenomas and cancers limited to the submucosa were considered together (pT0-1). The sensitivity, specificity, overall accuracy rate, positive predictive value, and negative predictive value of endorectal ultrasonography for pT0-1 were 86%, 95.6%, 91.3%, 94.9% and 88.7%. Those for nodal involvement were 45.4%, 95.5%, 83%, 76.9% and 84%, with 3 false positive results and 12 false negative. For combined pT0-1 and pN0, endorectal ultrasonography showed an 87.5% sensitivity, 95.9% specificity, 92% overall accuracy rate, 94.9% positive predictive value and 90.2% negative predictive value. Endorectal linear array ultrasonography is a reliable tool to detect rectal neoplasias suitable for local treatment. Copyright © 2011 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.
Cancer-associated fibroblasts as target and tool in cancer therapeutics and diagnostics.
De Vlieghere, Elly; Verset, Laurine; Demetter, Pieter; Bracke, Marc; De Wever, Olivier
2015-10-01
Cancer-associated fibroblasts (CAFs) are drivers of tumour progression and are considered as a target and a tool in cancer diagnostic and therapeutic applications. An increased abundance of CAFs or CAF signatures are recognized as a bad prognostic marker in several cancer types. Tumour-environment biomimetics strongly improve our understanding of the communication between CAFs, cancer cells and other host cells. Several experimental drugs targeting CAFs are in clinical trials for multiple tumour entities; alternatively, CAFs can be exploited as a tool to characterize the functionality of circulating tumour cells or to capture them as a tool to prevent metastasis. The continuous interaction between tissue engineers, biomaterial experts and cancer researchers creates the possibility to biomimic the tumour-environment and provides new opportunities in cancer diagnostics and management.
Rossi, E D; Martini, M; Straccia, P; Bizzarro, T; Fadda, G; Larocca, L M
2016-02-01
Our aim was to evaluate the feasibility and diagnostic accuracy of liquid-based cytology (LBC) on lymph node fine needle aspiration (FNA). FNA may fulfil a challenging role in the evaluation of the majority of primary (benign and malignant) diagnoses as well as metastatic lymph node lesions. Although the morphological features may be quite easily recognized, cytological samples with a scant cellular component may raise some issues. We appraised 263 cytological lymph nodes from different body regions analysed between January and December 2013, including 137 male and 126 female patients, and processed with LBC. The cytological diagnoses included 160 benign and 103 malignant lesions. We reported 35 benign and 73 malignant lesions from 108 with surgical follow-up. The latter malignant series included 68 metastatic lesions, four suspicious for malignancy and one inadequate sample. The cytological diagnoses were supported by 62 conclusive immunocytochemical and 28 molecular analyses. Of the 108 cases, we documented 35 true negatives, 72 true positives, one false negative and no false positives, resulting in 98.6% sensitivity, 100% specificity, 99% diagnostic accuracy, 97.2% negative predictive value and 100% positive predictive value. FNA represents the first diagnostic tool in lymph node management and a reliable approach in order to avoid an excision biopsy. Furthermore, LBC is a feasible method for ancillary tests for which methanol-fixed samples are suitable, such as immunocytochemistry and molecular analysis. © 2014 John Wiley & Sons Ltd.
Britton, Sumudu; Cheng, Qin; McCarthy, James S
2016-02-16
As malaria transmission continues to decrease, an increasing number of countries will enter pre-elimination and elimination. To interrupt transmission, changes in control strategies are likely to require more accurate identification of all carriers of Plasmodium parasites, both symptomatic and asymptomatic, using diagnostic tools that are highly sensitive, high throughput and with fast turnaround times preferably performed in local health service settings. Currently available immunochromatographic lateral flow rapid diagnostic tests and field microscopy are unlikely to consistently detect infections at parasite densities less than 100 parasites/µL making them insufficiently sensitive for detecting all carriers. Molecular diagnostic platforms, such as PCR and LAMP, are currently available in reference laboratories, but at a cost both financially and in turnaround time. This review describes the recent progress in developing molecular diagnostic tools in terms of their capacity for high throughput and potential for performance in non-reference laboratories for malaria elimination.
Sharma, Shikha; Zapatero-Rodríguez, Julia; O'Kennedy, Richard
The increased incidence and the significant health burden associated with carcinoma of the prostate have led to substantial changes in its diagnosis over the past century. Despite technological advancements, the management of prostate cancer has become progressively more complex and controversial for both early and late-stage disease. The limitations and potential harms associated with the use of prostate-specific antigen (PSA) as a diagnostic marker have stimulated significant investigation of numerous novel biomarkers that demonstrate varying capacities to detect prostate cancer and can decrease unnecessary biopsies. However, only a few of these markers have been approved for specific clinical settings while the others have not been adequately validated for use. This review systematically and critically assesses ongoing issues and emerging challenges in the current state of prostate cancer diagnostic tools and the need for disruptive next generation tools based on analysis of combinations of these biomarkers to enhance predictive accuracy which will benefit clinical diagnostics and patient welfare. Copyright © 2016. Published by Elsevier Inc.
Wang, Shuqi; Hu, Wei
2014-01-01
Schistosomiasis, caused by dioecious flatworms in the genus Schistosoma, is torturing people from many developing countries nowadays and frequently leads to severe morbidity and mortality of the patients. Praziquantel based chemotherapy and morbidity control for this disease adopted currently necessitate viable and efficient diagnostic technologies. Fortunately, those “-omics” researches, which rely on high-throughput experimental technologies to produce massive amounts of informative data, have substantially contributed to the exploitation and innovation of diagnostic tools of schistosomiasis. In its first section, this review provides a concise conclusion on the progresses pertaining to schistosomal “-omics” researches to date, followed by a comprehensive section on the diagnostic methods of schistosomiasis, especially those innovative ones based on the detection of antibodies, antigens, nucleic acids, and metabolites with a focus on those achievements inspired by “-omics” researches. Finally, suggestions about the design of future diagnostic tools of schistosomiasis are proposed, in order to better harness those data produced by “-omics” studies. PMID:25018752
Spotlight on Fluorescent Biosensors—Tools for Diagnostics and Drug Discovery
2013-01-01
Fluorescent biosensors constitute potent tools for probing biomolecules in their natural environment and for visualizing dynamic processes in complex biological samples, living cells, and organisms. They are well suited for highlighting molecular alterations associated with pathological disorders, thereby offering means of implementing sensitive and alternative technologies for diagnostic purposes. They constitute attractive tools for drug discovery programs, from high throughput screening assays to preclinical studies. PMID:24900780
Chakrabarti, Sudipta; Datta, Alok Sobhan; Hira, Michael
2012-01-01
Though open surgical biopsy is the procedure of choice for the diagnosis of bone tumors, many disadvantages are associated with this approach. The present study was undertaken to evaluate the role of fine needle aspiration cytology (FNAC) as a diagnostic tool in cases of bony tumors and tumor-like lesions which may be conducted in centers where facilities for surgical biopsies are inadequate. The study population consisted of 51 cases presenting with a skeletal mass. After clinical evaluation, radiological correlation was done to assess the nature and extent of each lesion. Fine needle aspiration was performed aseptically and smears were prepared. Patients subsequently underwent open surgical biopsy and tissue samples were obtained for histopathological examination. Standard statistical methods were applied for analysis of data. Adequate material was not obtained even after repeated aspiration in seven cases, six of which were benign. Among the remaining 44 cases, diagnosis of malignancy was correctly provided in 28 (93.3%) out of 30 cases and categorical diagnosis in 20 (66.67%). Interpretation of cytology was more difficult in cases of benign and tumor-like lesions, with a categorical opinion only possible in seven (50%) cases. Statistical analysis showed FNAC with malignant tumors to have high sensitivity (93.3%), specificity (92.9%) and positive predictive value of 96.6%, whereas the negative predictive value was 86.7%. FNAC should be included in the diagnostic workup of a skeletal tumor because of its simplicity and reliability. However, a definitive pathologic diagnosis heavily depends on compatible clinical and radiologic features which can only be accomplished by teamwork. The cytological technique applied in this study could detect many bone tumors and tumor-like conditions and appears particularly suitable as a diagnostic technique for rural regions of India as other developing countries.
40 CFR 1033.110 - Emission diagnostics-general requirements.
Code of Federal Regulations, 2011 CFR
2011-07-01
... engine operation. (d) Record and store in computer memory any diagnostic trouble codes showing a... and understand the diagnostic trouble codes stored in the onboard computer with generic tools and...
Evaluating the Diagnostic Validity of a Facet-Based Formative Assessment System
ERIC Educational Resources Information Center
DeBarger, Angela Haydel; DiBello, Louis; Minstrell, Jim; Feng, Mingyu; Stout, William; Pellegrino, James; Haertel, Geneva; Harris, Christopher; Ructinger, Liliana
2011-01-01
This paper describes methods for an alignment study and psychometric analyses of a formative assessment system, Diagnoser Tools for physics. Diagnoser Tools begin with facet clusters as the interpretive framework for designing questions and instructional activities. Thus each question in the diagnostic assessments includes distractors that…
The CVI Watershed Health Assessment Tool Investigating Fisheries, WHAT IF version 2, currently contains five components: Regional Prioritization Tool, Hydrologic Tool, Clustering Tool, Habitat Suitability Tool, BASS model
Rabenhold, Markus; Steiniger, Frank; Fahr, Alfred; Hilger, Ingrid
2015-01-01
Optical imaging offers a wide range of diagnostic modalities and has attracted a lot of interest as a tool for biomedical imaging. Despite the enormous number of imaging techniques currently available and the progress in instrumentation, there is still a need for highly sensitive probes that are suitable for in vivo imaging. One typical problem of available preclinical fluorescent probes is their rapid clearance in vivo, which reduces their imaging sensitivity. To circumvent rapid clearance, increase number of dye molecules at the target site, and thereby reduce background autofluorescence, encapsulation of the near-infrared fluorescent dye, DY-676-COOH in liposomes and verification of its potential for in vivo imaging of inflammation was done. DY-676 is known for its ability to self-quench at high concentrations. We first determined the concentration suitable for self-quenching, and then encapsulated this quenching concentration into the aqueous interior of PEGylated liposomes. To substantiate the quenching and activation potential of the liposomes we use a harsh freezing method which leads to damage of liposomal membranes without affecting the encapsulated dye. The liposomes characterized by a high level of fluorescence quenching were termed Lip-Q. We show by experiments with different cell lines that uptake of Lip-Q is predominantly by phagocytosis which in turn enabled the characterization of its potential as a tool for in vivo imaging of inflammation in mice models. Furthermore, we use a zymosan-induced edema model in mice to substantiate the potential of Lip-Q in optical imaging of inflammation in vivo. Considering possible uptake due to inflammation-induced enhanced permeability and retention (EPR) effect, an always-on liposome formulation with low, non-quenched concentration of DY-676-COOH (termed Lip-dQ) and the free DY-676-COOH were compared with Lip-Q in animal trials. PMID:25591069
WE-AB-206-01: Diagnostic Ultrasound Imaging Quality Assurance
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zagzebski, J.
The involvement of medical physicists in diagnostic ultrasound imaging service is increasing due to QC and accreditation requirements. The goal of this ultrasound hands-on workshop is to demonstrate quality control (QC) testing in diagnostic ultrasound and to provide updates in ACR ultrasound accreditation requirements. The first half of this workshop will include two presentations reviewing diagnostic ultrasound QA/QC and ACR ultrasound accreditation requirements. The second half of the workshop will include live demonstrations of basic QC tests. An array of ultrasound testing phantoms and ultrasound scanners will be available for attendees to learn diagnostic ultrasound QC in a hands-on environmentmore » with live demonstrations and on-site instructors. The targeted attendees are medical physicists in diagnostic imaging. Learning Objectives: Gain familiarity with common elements of a QA/QC program for diagnostic ultrasound imaging dentify QC tools available for testing diagnostic ultrasound systems and learn how to use these tools Learn ACR ultrasound accreditation requirements Jennifer Walter is an employee of American College of Radiology on Ultrasound Accreditation.« less
Diagnosis demystified: CT as diagnostic tool in endodontics
Shruthi, Nagaraja; Sreenivasa Murthy, B V; Sundaresh, K J; Mallikarjuna, Rachappa
2013-01-01
Diagnosis in endodontics is usually based on clinical and radiographical presentations, which are only empirical methods. The role of healing profession is to apply knowledge and skills towards maintaining and restoring the patient's health. Recent advances in imaging technologies have added to correct interpretation and diagnosis. CT is proving to be an effective tool in solving endodontic mysteries through its three-dimensional visualisation. CT imaging offers many diagnostic advantages to produce reconstructed images in selected projection and low-contrast resolution far superior to that of all other X-ray imaging modalities. This case report is an endeavour towards effective treatment planning of cases with root fracture, root resorption using spiral CT as an adjuvant diagnostic tool. PMID:23814212
Comparison of seven fall risk assessment tools in community-dwelling Korean older women.
Kim, Taekyoung; Xiong, Shuping
2017-03-01
This study aimed to compare seven widely used fall risk assessment tools in terms of validity and practicality, and to provide a guideline for choosing appropriate fall risk assessment tools for elderly Koreans. Sixty community-dwelling Korean older women (30 fallers and 30 matched non-fallers) were evaluated. Performance measures of all tools were compared between the faller and non-faller groups through two sample t-tests. Receiver Operating Characteristic curves were generated with odds ratios for discriminant analysis. Results showed that four tools had significant discriminative power, and the shortened version of Falls Efficacy Scale (SFES) showed excellent discriminant validity, followed by Berg Balance Scale (BBS) with acceptable discriminant validity. The Mini Balance Evaluation System Test and Timed Up and Go, however, had limited discriminant validities. In terms of practicality, SFES was also excellent. These findings suggest that SFES is the most suitable tool for assessing the fall risks of community-dwelling Korean older women, followed by BBS. Practitioner Summary: There is no general guideline on which fall risk assessment tools are suitable for community-dwelling Korean older women. This study compared seven widely used assessment tools in terms of validity and practicality. Results suggested that the short Falls Efficacy Scale is the most suitable tool, followed by Berg Balance Scale.
The choice of amniotic fluid in metabolomics for the monitoring of fetus health.
Palmas, Francesco; Fattuoni, Claudia; Noto, Antonio; Barberini, Luigi; Dessì, Angelica; Fanos, Vassilios
2016-01-01
Amniotic fluid (AF) is a biological fluid in which metabolite transport is regulated by the placenta, the permeable skin, fetal lung egress and gastric fluid. During pregnancy, the composition of AF changes from similar to the interstitial fluid of the mother, to a more complex system, influenced by the fetus's urine. Since AF reflects the mother's and the fetus's health status at the same time, it may be an important diagnostic tool for a wider spectrum of clinical conditions. Indeed, the metabolic characterization of AF in relation to pathological occurrences may lead to the discovery of new biomarkers for a better clinical practice. For this reason, metabolomics may be the most suitable strategy for this task. In this review, research works on metabolomic AF analysis are discussed according to the morbidity of interest, being preterm birth/labor, gestational age and diabetes and fetal malformations, along with a number of other important studies.
Importance of inlet boundary conditions for numerical simulation of combustor flows
NASA Technical Reports Server (NTRS)
Sturgess, G. J.; Syed, S. A.; Mcmanus, K. R.
1983-01-01
Fluid dynamic computer codes for the mathematical simulation of problems in gas turbine engine combustion systems are required as design and diagnostic tools. To eventually achieve a performance standard with these codes of more than qualitative accuracy it is desirable to use benchmark experiments for validation studies. Typical of the fluid dynamic computer codes being developed for combustor simulations is the TEACH (Teaching Elliptic Axisymmetric Characteristics Heuristically) solution procedure. It is difficult to find suitable experiments which satisfy the present definition of benchmark quality. For the majority of the available experiments there is a lack of information concerning the boundary conditions. A standard TEACH-type numerical technique is applied to a number of test-case experiments. It is found that numerical simulations of gas turbine combustor-relevant flows can be sensitive to the plane at which the calculations start and the spatial distributions of inlet quantities for swirling flows.
Design Aspects of the Rayleigh Convection Code
NASA Astrophysics Data System (ADS)
Featherstone, N. A.
2017-12-01
Understanding the long-term generation of planetary or stellar magnetic field requires complementary knowledge of the large-scale fluid dynamics pervading large fractions of the object's interior. Such large-scale motions are sensitive to the system's geometry which, in planets and stars, is spherical to a good approximation. As a result, computational models designed to study such systems often solve the MHD equations in spherical geometry, frequently employing a spectral approach involving spherical harmonics. We present computational and user-interface design aspects of one such modeling tool, the Rayleigh convection code, which is suitable for deployment on desktop and petascale-hpc architectures alike. In this poster, we will present an overview of this code's parallel design and its built-in diagnostics-output package. Rayleigh has been developed with NSF support through the Computational Infrastructure for Geodynamics and is expected to be released as open-source software in winter 2017/2018.
FT-Raman spectral analysis of human urinary stones.
Selvaraju, R; Raja, A; Thiruppathi, G
2012-12-01
FT-Raman spectroscopy is the most useful tool for the purpose of bio-medical diagnostics. In the present study, FT-Raman spectral method is used to investigate the chemical composition of urinary calculi. Urinary calculi multi-components such as calcium oxalate, hydroxyl apatite, struvite and uric acid are studied. FT-Raman spectrum has been recorded in the range of 3500-400 cm(-1). Chemical compounds are identified by Raman spectroscopic technique. The quantitative estimations of calcium oxalate monohydrate (COM) 1463 cm(-1), calcium oxalate dehydrate (COD) 1478 cm(-1), hydroxyl apatite 959 cm(-1), struvite 575 cm(-1), uric acid 1283 cm(-1) and oxammite (ammonium oxalate monohydrate) 2129 cm(-1) are calculated using particular peaks of FT-Raman spectrum. The quantitative estimation of human urinary stones suitable for the single calibration curve was performed. Copyright © 2012 Elsevier B.V. All rights reserved.
A Lateral Flow Biosensor for the Detection of Single Nucleotide Polymorphisms.
Zeng, Lingwen; Xiao, Zhuo
2017-01-01
A lateral flow biosensor (LFB) is introduced for the detection of single nucleotide polymorphisms (SNPs). The assay is composed of two steps: circular strand displacement reaction and lateral flow biosensor detection. In step 1, the nucleotide at SNP site is recognized by T4 DNA ligase and the signal is amplified by strand displacement DNA polymerase, which can be accomplished at a constant temperature. In step 2, the reaction product of step 1 is detected by a lateral flow biosensor, which is a rapid and cost effective tool for nuclei acid detection. Comparing with conventional methods, it requires no complicated machines. It is suitable for the use of point of care diagnostics. Therefore, this simple, cost effective, robust, and promising LFB detection method of SNP has great potential for the detection of genetic diseases, personalized medicine, cancer related mutations, and drug-resistant mutations of infectious agents.
Alnasser, Yossef; Ferradas, Cusi; Clark, Taryn; Calderon, Maritza; Gurbillon, Alejandro; Gamboa, Dionicia; McKakpo, Uri S.; Quakyi, Isabella A.; Bosompem, Kwabena M.; Sullivan, David J.; Vinetz, Joseph M.; Gilman, Robert H.
2016-01-01
Plasmodium vivax is the most prevalent cause of human malaria in the world and can lead to severe disease with high potential for relapse. Its genetic and geographic diversities make it challenging to control. P. vivax is understudied and to achieve control of malaria in endemic areas, a rapid, accurate, and simple diagnostic tool is necessary. In this pilot study, we found that a colorimetric system using AuNPs and MSP10 DNA detection in urine can provide fast, easy, and inexpensive identification of P. vivax. The test exhibited promising sensitivity (84%), high specificity (97%), and only mild cross-reactivity with P. falciparum (21%). It is simple to use, with a visible color change that negates the need for a spectrometer, making it suitable for use in austere conditions. Using urine eliminates the need for finger-prick, increasing both the safety profile and patient acceptance of this model. PMID:27706158
Development of an intelligent diagnostic system for reusable rocket engine control
NASA Technical Reports Server (NTRS)
Anex, R. P.; Russell, J. R.; Guo, T.-H.
1991-01-01
A description of an intelligent diagnostic system for the Space Shuttle Main Engines (SSME) is presented. This system is suitable for incorporation in an intelligent controller which implements accommodating closed-loop control to extend engine life and maximize available performance. The diagnostic system architecture is a modular, hierarchical, blackboard system which is particularly well suited for real-time implementation of a system which must be repeatedly updated and extended. The diagnostic problem is formulated as a hierarchical classification problem in which the failure hypotheses are represented in terms of predefined data patterns. The diagnostic expert system incorporates techniques for priority-based diagnostics, the combination of analytical and heuristic knowledge for diagnosis, integration of different AI systems, and the implementation of hierarchical distributed systems. A prototype reusable rocket engine diagnostic system (ReREDS) has been implemented. The prototype user interface and diagnostic performance using SSME test data are described.
Autoimmune diagnostics: the technology, the strategy and the clinical governance.
Bizzaro, Nicola; Tozzoli, Renato; Villalta, Danilo
2015-02-01
In recent years, there has been a profound change in autoimmune diagnostics. From long, tiring and inaccurate manual methods, the art of diagnostics has turned to modern, rapid and automated technology. New antibody tests have been developed, and almost all autoimmune diseases now have some specific diagnostic markers. The current need to make the most of available economic and human resources has led to the production of diagnostic algorithms and guidelines designated for optimal strategic use of the tests and to increase the diagnostic appropriateness. An important role in this scenario was assumed by the laboratory autoimmunologist, whose task is not only to govern the analytical phase, but also to help clinicians in correctly choosing the most suitable test for each clinical situation and provide consultancy support. In this review, we summarize recent advances in technology, describe the diagnostic strategies and highlight the current role of the laboratory autoimmunologist in the clinical governance of autoimmune diagnostics.
Laser speckle and skin cancer: skin roughness assessment
NASA Astrophysics Data System (ADS)
Lee, Tim K.; Tchvialeva, Lioudmila; Zeng, Haishan; McLean, David I.; Lui, Harvey
2009-10-01
Incidence of skin cancer has been increasing rapidly since the last few decades. Non-invasive optical diagnostic tools may improve the diagnostic accuracy. In this paper, skin structure, skin cancer statistics and subtypes of skin cancer are briefly reviewed. Among the subtypes, malignant melanoma is the most aggressive and dangerous; early detection dramatically improves the prognosis. Therefore, a non-invasive diagnostic tool for malignant melanoma is especially needed. In addition, in order for the diagnostic tool to be useful, it must be able to differentiate melanoma from common skin conditions such as seborrheic keratosis, a benign skin disease that resembles melanoma according to the well known clinical-assessment ABCD rule. The key diagnostic feature between these two diseases is surface roughness. Based on laser speckle contrast, our research team has recently developed a portable, optical, non-invasive, in-vivo diagnostic device for quantifying skin surface roughness. The methodology of our technique is described in details. Examining the preliminary data collected in a pilot clinical study for the prototype, we found that there was a difference in roughness between melanoma and seborrheic keratosis. In fact, there was a perfect cutoff value for the two diseases based on our initial data.
Hair: A Diagnostic Tool to Complement Blood Serum and Urine.
ERIC Educational Resources Information Center
Maugh, Thomas H., II
1978-01-01
Trace elements and some drugs can be identified in hair and it seems likely that other organic chemicals will be identifiable in the future. Since hair is so easily collected, stored, and analyzed it promises to be an ideal complement to serum and urine analysis as a diagnostic tool. (BB)
Baker, Elizabeth A; Ledford, Cynthia H; Fogg, Louis; Way, David P; Park, Yoon Soo
2015-01-01
Construct: Clinical skills are used in the care of patients, including reporting, diagnostic reasoning, and decision-making skills. Written comprehensive new patient admission notes (H&Ps) are a ubiquitous part of student education but are underutilized in the assessment of clinical skills. The interpretive summary, differential diagnosis, explanation of reasoning, and alternatives (IDEA) assessment tool was developed to assess students' clinical skills using written comprehensive new patient admission notes. The validity evidence for assessment of clinical skills using clinical documentation following authentic patient encounters has not been well documented. Diagnostic justification tools and postencounter notes are described in the literature (1,2) but are based on standardized patient encounters. To our knowledge, the IDEA assessment tool is the first published tool that uses medical students' H&Ps to rate students' clinical skills. The IDEA assessment tool is a 15-item instrument that asks evaluators to rate students' reporting, diagnostic reasoning, and decision-making skills based on medical students' new patient admission notes. This study presents validity evidence in support of the IDEA assessment tool using Messick's unified framework, including content (theoretical framework), response process (interrater reliability), internal structure (factor analysis and internal-consistency reliability), and relationship to other variables. Validity evidence is based on results from four studies conducted between 2010 and 2013. First, the factor analysis (2010, n = 216) yielded a three-factor solution, measuring patient story, IDEA, and completeness, with reliabilities of .79, .88, and .79, respectively. Second, an initial interrater reliability study (2010) involving two raters demonstrated fair to moderate consensus (κ = .21-.56, ρ =.42-.79). Third, a second interrater reliability study (2011) with 22 trained raters also demonstrated fair to moderate agreement (intraclass correlations [ICCs] = .29-.67). There was moderate reliability for all three skill domains, including reporting skills (ICC = .53), diagnostic reasoning skills (ICC = .64), and decision-making skills (ICC = .63). Fourth, there was a significant correlation between IDEA rating scores (2010-2013) and final Internal Medicine clerkship grades (r = .24), 95% confidence interval (CI) [.15, .33]. The IDEA assessment tool is a novel tool with validity evidence to support its use in the assessment of students' reporting, diagnostic reasoning, and decision-making skills. The moderate reliability achieved supports formative or lower stakes summative uses rather than high-stakes summative judgments.
Swartz, Jordan; Koziatek, Christian; Theobald, Jason; Smith, Silas; Iturrate, Eduardo
2017-05-01
Testing for venous thromboembolism (VTE) is associated with cost and risk to patients (e.g. radiation). To assess the appropriateness of imaging utilization at the provider level, it is important to know that provider's diagnostic yield (percentage of tests positive for the diagnostic entity of interest). However, determining diagnostic yield typically requires either time-consuming, manual review of radiology reports or the use of complex and/or proprietary natural language processing software. The objectives of this study were twofold: 1) to develop and implement a simple, user-configurable, and open-source natural language processing tool to classify radiology reports with high accuracy and 2) to use the results of the tool to design a provider-specific VTE imaging dashboard, consisting of both utilization rate and diagnostic yield. Two physicians reviewed a training set of 400 lower extremity ultrasound (UTZ) and computed tomography pulmonary angiogram (CTPA) reports to understand the language used in VTE-positive and VTE-negative reports. The insights from this review informed the arguments to the five modifiable parameters of the NLP tool. A validation set of 2,000 studies was then independently classified by the reviewers and by the tool; the classifications were compared and the performance of the tool was calculated. The tool was highly accurate in classifying the presence and absence of VTE for both the UTZ (sensitivity 95.7%; 95% CI 91.5-99.8, specificity 100%; 95% CI 100-100) and CTPA reports (sensitivity 97.1%; 95% CI 94.3-99.9, specificity 98.6%; 95% CI 97.8-99.4). The diagnostic yield was then calculated at the individual provider level and the imaging dashboard was created. We have created a novel NLP tool designed for users without a background in computer programming, which has been used to classify venous thromboembolism reports with a high degree of accuracy. The tool is open-source and available for download at http://iturrate.com/simpleNLP. Results obtained using this tool can be applied to enhance quality by presenting information about utilization and yield to providers via an imaging dashboard. Copyright © 2017 Elsevier B.V. All rights reserved.
Kanne, Stephen M; Carpenter, Laura Arnstein; Warren, Zachary
2018-05-07
There are many available tools with varying levels of accuracy designed to screen for Autism Spectrum Disorder (ASD) in young children, both in the general population and specifically among those referred for developmental concerns. With burgeoning waitlists for comprehensive diagnostic ASD assessments, finding accurate methods and tools for advancing diagnostic triage becomes increasingly important. The current study compares the efficacy of four oft used paper and pencil measures, the Modified Checklist for Autism in Toddlers Revised with Follow-up, the Social Responsiveness Scale, Second Edition, and the Social Communication Questionnaire, and the Child Behavior Checklist to a novel mobile-health screening tool developed by Cognoa, Inc. (Cognoa) in a group of children 18-72 months of age. The Cognoa tool may have potential benefits as it integrates a series of parent-report questions with remote clinical ratings of brief video segments uploaded via parent's smartphones to calculate level of ASD risk. Participants were referred to one of three tertiary care diagnostic centers for ASD-related concerns (n = 230) and received a best estimate ASD diagnosis. Analysis and comparison of psychometric properties indicated potential advantages for Cognoa within this clinical sample across age ranges not often covered by another single measure/tool. Autism Res 2018. © 2018 International Society for Autism Research, Wiley Periodicals, Inc. With the wait times getting longer for comprehensive Autism Spectrum Disorder (ASD) diagnostic assessments, it is becoming increasingly important to find accurate tools to screen for ASD. The current study compares four screening measures that have been in use for some time to a novel mobile-health screening tool, called Cognoa. The Cognoa tool is novel because it integrates parent-report questions with clinical ratings of brief video segments uploaded via parent's smartphones to calculate ASD risk. Two hundred thirty children who were referred to one of three ASD specialty diagnostic centers to see if they had ASD participated in the study. A direct comparison indicated potential advantages for Cognoa not often covered by another single measure/tool. © 2018 International Society for Autism Research, Wiley Periodicals, Inc.
Decker, Sebastian O; Sigl, Annette; Grumaz, Christian; Stevens, Philip; Vainshtein, Yevhen; Zimmermann, Stefan; Weigand, Markus A; Hofer, Stefan; Sohn, Kai; Brenner, Thorsten
2017-08-18
Fungi are of increasing importance in sepsis. However, culture-based diagnostic procedures are associated with relevant weaknesses. Therefore, culture- and next-generation sequencing (NGS)-based fungal findings as well as corresponding plasma levels of β-d-glucan, interferon gamma (INF-γ), tumor necrosis factor alpha (TNF-α), interleukin (IL)-2, -4, -6, -10, -17A, and mid-regional proadrenomedullin (MR-proADM) were evaluated in 50 septic patients at six consecutive time points within 28 days after sepsis onset. Furthermore, immune-response patterns during infections with Candida spp. were studied in a reconstituted human epithelium model. In total, 22% ( n = 11) of patients suffered from a fungal infection. An NGS-based diagnostic approach appeared to be suitable for the identification of fungal pathogens in patients suffering from fungemia as well as in patients with negative blood cultures. Moreover, MR-proADM and IL-17A in plasma proved suitable for the identification of patients with a fungal infection. Using RNA-seq., adrenomedullin (ADM) was shown to be a target gene which is upregulated early after an epithelial infection with Candida spp. In summary, an NGS-based diagnostic approach was able to close the diagnostic gap of routinely used culture-based diagnostic procedures, which can be further facilitated by plasmatic measurements of MR-proADM and IL-17A. In addition, ADM was identified as an early target gene in response to epithelial infections with Candida spp.
Gwee, Kok-Ann; Bergmans, Paul; Kim, JinYong; Coudsy, Bogdana; Sim, Angelia; Chen, Minhu; Lin, Lin; Hou, Xiaohua; Wang, Huahong; Goh, Khean-Lee; Pangilinan, John A; Kim, Nayoung; des Varannes, Stanislas Bruley
2017-01-01
Background/Aims There is a need for a simple and practical tool adapted for the diagnosis of chronic constipation (CC) in the Asian population. This study compared the Asian Neurogastroenterology and Motility Association (ANMA) CC tool and Rome III criteria for the diagnosis of CC in Asian subjects. Methods This multicenter, cross-sectional study included subjects presenting at outpatient gastrointestinal clinics across Asia. Subjects with CC alert symptoms completed a combination Diagnosis Questionnaire to obtain a diagnosis based on 4 different diagnostic methods: self-defined, investigator’s judgment, ANMA CC tool, and Rome III criteria. The primary endpoint was the level of agreement/disagreement between the ANMA CC diagnostic tool and Rome III criteria for the diagnosis of CC. Results The primary analysis comprised of 449 subjects, 414 of whom had a positive diagnosis according to the ANMA CC tool. Rome III positive/ANMA positive and Rome III negative/ANMA negative diagnoses were reported in 76.8% and 7.8% of subjects, respectively, resulting in an overall percentage agreement of 84.6% between the 2 diagnostic methods. The overall percentage disagreement between these 2 diagnostic methods was 15.4%. A higher level of agreement was seen between the ANMA CC tool and self-defined (374 subjects [90.3%]) or investigator’s judgment criteria (388 subjects [93.7%]) compared with the Rome III criteria. Conclusion This study demonstrates that the ANMA CC tool can be a useful for Asian patients with CC. PMID:27764907
The Dundee Ready Education Environment Measure (DREEM): a review of its adoption and use.
Miles, Susan; Swift, Louise; Leinster, Sam J
2012-01-01
The Dundee Ready Education Environment Measure (DREEM) was published in 1997 as a tool to evaluate educational environments of medical schools and other health training settings and a recent review concluded that it was the most suitable such instrument. This study aimed to review the settings and purposes to which the DREEM has been applied and the approaches used to analyse and report it, with a view to guiding future users towards appropriate methodology. A systematic literature review was conducted using the Web of Knowledge databases of all articles reporting DREEM data between 1997 and 4 January 2011. The review found 40 publications, using data from 20 countries. DREEM is used in evaluation for diagnostic purposes, comparison between different groups and comparison with ideal/expected scores. A variety of non-parametric and parametric statistical methods have been applied, but their use is inconsistent. DREEM has been used internationally for different purposes and is regarded as a useful tool by users. However, reporting and analysis differs between publications. This lack of uniformity makes comparison between institutions difficult. Most users of DREEM are not statisticians and there is a need for informed guidelines on its reporting and statistical analysis.
The Wild Side of Disease Control at the Wildlife-Livestock-Human Interface: A Review
Gortazar, Christian; Diez-Delgado, Iratxe; Barasona, Jose Angel; Vicente, Joaquin; De La Fuente, Jose; Boadella, Mariana
2015-01-01
The control of diseases shared with wildlife requires the development of strategies that will reduce pathogen transmission between wildlife and both domestic animals and human beings. This review describes and criticizes the options currently applied and attempts to forecast wildlife disease control in the coming decades. Establishing a proper surveillance and monitoring scheme (disease and population wise) is the absolute priority before even making the decision as to whether or not to intervene. Disease control can be achieved by different means, including: (1) preventive actions, (2) arthropod vector control, (3) host population control through random or selective culling, habitat management or reproductive control, and (4) vaccination. The alternative options of zoning or no-action should also be considered, particularly in view of a cost/benefit assessment. Ideally, tools from several fields should be combined in an integrated control strategy. The success of disease control in wildlife depends on many factors, including disease ecology, natural history, and the characteristics of the pathogen, the availability of suitable diagnostic tools, the characteristics of the domestic and wildlife host(s) and vectors, the geographical spread of the problem, the scale of the control effort and stakeholders’ attitudes. PMID:26664926
Ultrasound-contrast-agent dispersion and velocity imaging for prostate cancer localization.
van Sloun, Ruud Jg; Demi, Libertario; Postema, Arnoud W; de la Rosette, Jean Jmch; Wijkstra, Hessel; Mischi, Massimo
2017-01-01
Prostate cancer (PCa) is the second-leading cause of cancer death in men; however, reliable tools for detection and localization are still lacking. Dynamic Contrast Enhanced UltraSound (DCE-US) is a diagnostic tool that is suitable for analysis of vascularization, by imaging an intravenously injected microbubble bolus. The localization of angiogenic vascularization associated with the development of tumors is of particular interest. Recently, methods for the analysis of the bolus convective dispersion process have shown promise to localize angiogenesis. However, independent estimation of dispersion was not possible due to the ambiguity between convection and dispersion. Therefore, in this study we propose a new method that considers the vascular network as a dynamic linear system, whose impulse response can be locally identified. To this end, model-based parameter estimation is employed, that permits extraction of the apparent dispersion coefficient (D), velocity (v), and Péclet number (Pe) of the system. Clinical evaluation using data recorded from 25 patients shows that the proposed method can be applied effectively to DCE-US, and is able to locally characterize the hemodynamics, yielding promising results (receiver-operating-characteristic curve area of 0.84) for prostate cancer localization. Copyright © 2016 Elsevier B.V. All rights reserved.
probeBase—an online resource for rRNA-targeted oligonucleotide probes and primers: new features 2016
Greuter, Daniel; Loy, Alexander; Horn, Matthias; Rattei, Thomas
2016-01-01
probeBase http://www.probebase.net is a manually maintained and curated database of rRNA-targeted oligonucleotide probes and primers. Contextual information and multiple options for evaluating in silico hybridization performance against the most recent rRNA sequence databases are provided for each oligonucleotide entry, which makes probeBase an important and frequently used resource for microbiology research and diagnostics. Here we present a major update of probeBase, which was last featured in the NAR Database Issue 2007. This update describes a complete remodeling of the database architecture and environment to accommodate computationally efficient access. Improved search functions, sequence match tools and data output now extend the opportunities for finding suitable hierarchical probe sets that target an organism or taxon at different taxonomic levels. To facilitate the identification of complementary probe sets for organisms represented by short rRNA sequence reads generated by amplicon sequencing or metagenomic analysis with next generation sequencing technologies such as Illumina and IonTorrent, we introduce a novel tool that recovers surrogate near full-length rRNA sequences for short query sequences and finds matching oligonucleotides in probeBase. PMID:26586809
Diagnostic Accuracy of Fall Risk Assessment Tools in People With Diabetic Peripheral Neuropathy
Pohl, Patricia S.; Mahnken, Jonathan D.; Kluding, Patricia M.
2012-01-01
Background Diabetic peripheral neuropathy affects nearly half of individuals with diabetes and leads to increased fall risk. Evidence addressing fall risk assessment for these individuals is lacking. Objective The purpose of this study was to identify which of 4 functional mobility fall risk assessment tools best discriminates, in people with diabetic peripheral neuropathy, between recurrent “fallers” and those who are not recurrent fallers. Design A cross-sectional study was conducted. Setting The study was conducted in a medical research university setting. Participants The participants were a convenience sample of 36 individuals between 40 and 65 years of age with diabetic peripheral neuropathy. Measurements Fall history was assessed retrospectively and was the criterion standard. Fall risk was assessed using the Functional Reach Test, the Timed “Up & Go” Test, the Berg Balance Scale, and the Dynamic Gait Index. Sensitivity, specificity, positive and negative likelihood ratios, and overall diagnostic accuracy were calculated for each fall risk assessment tool. Receiver operating characteristic curves were used to estimate modified cutoff scores for each fall risk assessment tool; indexes then were recalculated. Results Ten of the 36 participants were classified as recurrent fallers. When traditional cutoff scores were used, the Dynamic Gait Index and Functional Reach Test demonstrated the highest sensitivity at only 30%; the Dynamic Gait Index also demonstrated the highest overall diagnostic accuracy. When modified cutoff scores were used, all tools demonstrated improved sensitivity (80% or 90%). Overall diagnostic accuracy improved for all tests except the Functional Reach Test; the Timed “Up & Go” Test demonstrated the highest diagnostic accuracy at 88.9%. Limitations The small sample size and retrospective fall history assessment were limitations of the study. Conclusions Modified cutoff scores improved diagnostic accuracy for 3 of 4 fall risk assessment tools when testing people with diabetic peripheral neuropathy. PMID:22836004
Nucleic acid purification from plants, animals and microbes in under 30 seconds
Zou, Yiping; Wang, Yuling; Wee, Eugene; Turni, Conny; Blackall, Patrick J.; Trau, Matt; Botella, Jose Ramon
2017-01-01
Nucleic acid amplification is a powerful molecular biology tool, although its use outside the modern laboratory environment is limited due to the relatively cumbersome methods required to extract nucleic acids from biological samples. To address this issue, we investigated a variety of materials for their suitability for nucleic acid capture and purification. We report here that untreated cellulose-based paper can rapidly capture nucleic acids within seconds and retain them during a single washing step, while contaminants present in complex biological samples are quickly removed. Building on this knowledge, we have successfully created an equipment-free nucleic acid extraction dipstick methodology that can obtain amplification-ready DNA and RNA from plants, animals, and microbes from difficult biological samples such as blood and leaves from adult trees in less than 30 seconds. The simplicity and speed of this method as well as the low cost and availability of suitable materials (e.g., common paper towelling), means that nucleic acid extraction is now more accessible and affordable for researchers and the broader community. Furthermore, when combined with recent advancements in isothermal amplification and naked eye DNA visualization techniques, the dipstick extraction technology makes performing molecular diagnostic assays achievable in limited resource settings including university and high school classrooms, field-based environments, and developing countries. PMID:29161268
Biologically relevant photoacoustic imaging phantoms with tunable optical and acoustic properties
Vogt, William C.; Jia, Congxian; Wear, Keith A.; Garra, Brian S.; Joshua Pfefer, T.
2016-01-01
Abstract. Established medical imaging technologies such as magnetic resonance imaging and computed tomography rely on well-validated tissue-simulating phantoms for standardized testing of device image quality. The availability of high-quality phantoms for optical-acoustic diagnostics such as photoacoustic tomography (PAT) will facilitate standardization and clinical translation of these emerging approaches. Materials used in prior PAT phantoms do not provide a suitable combination of long-term stability and realistic acoustic and optical properties. Therefore, we have investigated the use of custom polyvinyl chloride plastisol (PVCP) formulations for imaging phantoms and identified a dual-plasticizer approach that provides biologically relevant ranges of relevant properties. Speed of sound and acoustic attenuation were determined over a frequency range of 4 to 9 MHz and optical absorption and scattering over a wavelength range of 400 to 1100 nm. We present characterization of several PVCP formulations, including one designed to mimic breast tissue. This material is used to construct a phantom comprised of an array of cylindrical, hemoglobin-filled inclusions for evaluation of penetration depth. Measurements with a custom near-infrared PAT imager provide quantitative and qualitative comparisons of phantom and tissue images. Results indicate that our PVCP material is uniquely suitable for PAT system image quality evaluation and may provide a practical tool for device validation and intercomparison. PMID:26886681
An accelerated diagnostic protocol for the early, safe discharge of low-risk chest pain patients.
Altherwi, Tawfeeq; Grad, Willis B
2015-07-01
Can an accelerated 2-hour diagnostic protocol using the cardiac troponin I (cTnI) measurement as the only biomarker be implemented to allow an earlier and safe discharge of low-risk chest pain patients? Than M, Cullen L, Aldous S, et al. 2-Hour accelerated diagnostic protocol to assess patients with chest pain symptoms using contemporary troponins as the only biomarker: the ADAPT trial. J Am Coll Cardiol 2012;59(23):2091-8. To determine whether an accelerated diagnostic protocol (ADP) for possible cardiac chest pain could identify low-risk patients suitable for early discharge using cTnI as the sole biomarker.
Molecular aspects of development and regulation of endometriosis
2014-01-01
Endometriosis is a common and painful condition affecting women of reproductive age. While the underlying pathophysiology is still largely unknown, much advancement has been made in understanding the progression of the disease. In recent years, a great deal of research has focused on non-invasive diagnostic tools, such as biomarkers, as well as identification of potential therapeutic targets. In this article, we will review the etiology and cellular mechanisms associated with endometriosis as well as the current diagnostic tools and therapies. We will then discuss the more recent genomic and proteomic studies and how these data may guide development of novel diagnostics and therapeutics. The current diagnostic tools are invasive and current therapies primarily treat the symptoms of endometriosis. Optimally, the advancement of “-omic” data will facilitate the development of non-invasive diagnostic biomarkers as well as therapeutics that target the pathophysiology of the disease and halt, or even reverse, progression. However, the amount of data generated by these types of studies is vast and bioinformatics analysis, such as we present here, will be critical to identification of appropriate targets for further study. PMID:24927773
Metzkes, J; Karsch, L; Kraft, S D; Pawelke, J; Richter, C; Schürer, M; Sobiella, M; Stiller, N; Zeil, K; Schramm, U
2012-12-01
In recent years, a new generation of high repetition rate (~10 Hz), high power (~100 TW) laser systems has stimulated intense research on laser-driven sources for fast protons. Considering experimental instrumentation, this development requires online diagnostics for protons to be added to the established offline detection tools such as solid state track detectors or radiochromic films. In this article, we present the design and characterization of a scintillator-based online detector that gives access to the angularly resolved proton distribution along one spatial dimension and resolves 10 different proton energy ranges. Conceived as an online detector for key parameters in laser-proton acceleration, such as the maximum proton energy and the angular distribution, the detector features a spatial resolution of ~1.3 mm and a spectral resolution better than 1.5 MeV for a maximum proton energy above 12 MeV in the current design. Regarding its areas of application, we consider the detector a useful complement to radiochromic films and Thomson parabola spectrometers, capable to give immediate feedback on the experimental performance. The detector was characterized at an electrostatic Van de Graaff tandetron accelerator and tested in a laser-proton acceleration experiment, proving its suitability as a diagnostic device for laser-accelerated protons.
Ayela, Cedric; Roquet, Francoise; Valera, Lionel; Granier, Claude; Nicu, Liviu; Pugnière, Martine
2007-06-15
This work reports on a complementary use of surface plasmon resonance (SPR) and quartz crystal microbalance with dissipation monitoring (QCM-D) technologies to study interactions between a peptide antigen and polyclonal antibodies, in an experimental format suitable for diagnostic assays of autoimmune diseases. In the chosen model, a synthetic peptide from the juxtamembrane region of IA-2 (a type 1 diabetes associated antigen) was immobilized by an optimized chemical protocol applicable to both BIACORE and QCM-D sensors. A thorough study of the peptide immobilization was performed to optimize the signal-to-noise ratio using mixed self-assembled monolayers (SAM) on a gold surface. Introduction of polyethylene glycol (EG(6)) chains into mixed SAM layers and addition of an anionic surfactant to the human serum reduced non-specific binding without modifying the viscoelasticity properties of the layer. Under our conditions, the antibody SPR detection limit was determined to be 0.2 nM in diluted human serum. This value is in agreement with the reported rank distribution of IA-2 antibodies in diabetic patient sera. Label-free and real-time technologies such as SPR and/or QCM-D could be precious tools in future diagnostic assays.
Ricciardi-Jorge, Taissa; Bordignon, Juliano; Koishi, Andrea; Zanluca, Camila; Mosimann, Ana Luiza; Duarte Dos Santos, Claudia Nunes
2017-11-24
Yellow fever is an arboviral disease that causes thousands of deaths every year in Africa and the Americas. However, few commercial diagnostic kits are available. Non-structural protein 1 (NS1) is an early marker of several flavivirus infections and is widely used to diagnose dengue virus (DENV) infection. Nonetheless, little is known about the dynamics of Yellow fever virus (YFV) NS1 expression and secretion, to encourage its use in diagnosis. To tackle this issue, we developed a quantitative NS1-capture ELISA specific for YFV using a monoclonal antibody and recombinant NS1 protein. This test was used to quantify NS1 in mosquito and human cell line cultures infected with vaccine and wild YFV strains. Our results showed that NS1 was detectable in the culture supernatants of both cell lines; however, a higher concentration was maintained as cell-associated rather than secreted into the extracellular milieu. A panel of 73 human samples was used to demonstrate the suitability of YFV NS1 as a diagnostic tool, resulting in 80% sensitivity, 100% specificity, a 100% positive predictive value and a 95.5% negative predictive value compared with RT-PCR. Overall, the developed NS1-capture ELISA showed potential as a promising assay for the detection of early YF infection.
NASA Astrophysics Data System (ADS)
Frerichs, Heinke; Effenberg, Florian; Schmitz, Oliver; Stephey, Laurie; W7-X Team
2016-10-01
Interpretation of spectroscopic measurements in the edge region of high-temperature plasmas can be a challenge due to line of sight integration effects. The EMC3-EIRENE code - a 3D fluid edge plasma and kinetic neutral gas transport code - is a suitable tool for full 3D reconstruction of such signals. A versatile synthetic diagnostic module has been developed recently which allows the realistic three dimensional setup of various plasma edge diagnostics to be captured. We present an analysis of recycling on the inboard limiter of W7-X during its startup phase in terms of a synthetic camera for Hα light observations and reconstruct the particle flux from these synthetic images based on ionization per photon coefficients (S/XB). We find that line of sight integration effects can lead to misinterpretation of data (redistribution of particle flux due to neutral gas diffusion), and that local plasma effects are important for the correct treatment of photon emissions. This work was supported by the U.S. Department of Energy (DOE) under Grant DE-SC0014210, by startup funds of the Department of Engineering Physics at the University of Wisconsin - Madison, and by the EUROfusion Consortium under Euratom Grant No 633053.
Retrieval of radiology reports citing critical findings with disease-specific customization.
Lacson, Ronilda; Sugarbaker, Nathanael; Prevedello, Luciano M; Ivan, Ip; Mar, Wendy; Andriole, Katherine P; Khorasani, Ramin
2012-01-01
Communication of critical results from diagnostic procedures between caregivers is a Joint Commission national patient safety goal. Evaluating critical result communication often requires manual analysis of voluminous data, especially when reviewing unstructured textual results of radiologic findings. Information retrieval (IR) tools can facilitate this process by enabling automated retrieval of radiology reports that cite critical imaging findings. However, IR tools that have been developed for one disease or imaging modality often need substantial reconfiguration before they can be utilized for another disease entity. THIS PAPER: 1) describes the process of customizing two Natural Language Processing (NLP) and Information Retrieval/Extraction applications - an open-source toolkit, A Nearly New Information Extraction system (ANNIE); and an application developed in-house, Information for Searching Content with an Ontology-Utilizing Toolkit (iSCOUT) - to illustrate the varying levels of customization required for different disease entities and; 2) evaluates each application's performance in identifying and retrieving radiology reports citing critical imaging findings for three distinct diseases, pulmonary nodule, pneumothorax, and pulmonary embolus. Both applications can be utilized for retrieval. iSCOUT and ANNIE had precision values between 0.90-0.98 and recall values between 0.79 and 0.94. ANNIE had consistently higher precision but required more customization. Understanding the customizations involved in utilizing NLP applications for various diseases will enable users to select the most suitable tool for specific tasks.
Retrieval of Radiology Reports Citing Critical Findings with Disease-Specific Customization
Lacson, Ronilda; Sugarbaker, Nathanael; Prevedello, Luciano M; Ivan, IP; Mar, Wendy; Andriole, Katherine P; Khorasani, Ramin
2012-01-01
Background: Communication of critical results from diagnostic procedures between caregivers is a Joint Commission national patient safety goal. Evaluating critical result communication often requires manual analysis of voluminous data, especially when reviewing unstructured textual results of radiologic findings. Information retrieval (IR) tools can facilitate this process by enabling automated retrieval of radiology reports that cite critical imaging findings. However, IR tools that have been developed for one disease or imaging modality often need substantial reconfiguration before they can be utilized for another disease entity. Purpose: This paper: 1) describes the process of customizing two Natural Language Processing (NLP) and Information Retrieval/Extraction applications – an open-source toolkit, A Nearly New Information Extraction system (ANNIE); and an application developed in-house, Information for Searching Content with an Ontology-Utilizing Toolkit (iSCOUT) – to illustrate the varying levels of customization required for different disease entities and; 2) evaluates each application’s performance in identifying and retrieving radiology reports citing critical imaging findings for three distinct diseases, pulmonary nodule, pneumothorax, and pulmonary embolus. Results: Both applications can be utilized for retrieval. iSCOUT and ANNIE had precision values between 0.90-0.98 and recall values between 0.79 and 0.94. ANNIE had consistently higher precision but required more customization. Conclusion: Understanding the customizations involved in utilizing NLP applications for various diseases will enable users to select the most suitable tool for specific tasks. PMID:22934127
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lu, Z.
The involvement of medical physicists in diagnostic ultrasound imaging service is increasing due to QC and accreditation requirements. The goal of this ultrasound hands-on workshop is to demonstrate quality control (QC) testing in diagnostic ultrasound and to provide updates in ACR ultrasound accreditation requirements. The first half of this workshop will include two presentations reviewing diagnostic ultrasound QA/QC and ACR ultrasound accreditation requirements. The second half of the workshop will include live demonstrations of basic QC tests. An array of ultrasound testing phantoms and ultrasound scanners will be available for attendees to learn diagnostic ultrasound QC in a hands-on environmentmore » with live demonstrations and on-site instructors. The targeted attendees are medical physicists in diagnostic imaging. Learning Objectives: Gain familiarity with common elements of a QA/QC program for diagnostic ultrasound imaging dentify QC tools available for testing diagnostic ultrasound systems and learn how to use these tools Learn ACR ultrasound accreditation requirements Jennifer Walter is an employee of American College of Radiology on Ultrasound Accreditation.« less
Molecular diagnostics of inflammatory disease: New tools and perspectives.
Garzorz-Stark, Natalie; Lauffer, Felix
2017-08-01
This essay reviews current approaches to establish novel molecular diagnostic tools for inflammatory skin diseases. Moreover, it highlights the importance of stratifying patients according to molecular signatures and revising current outdated disease classification systems to eventually reach the goal of personalized medicine. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Talundzic, Eldin; Maganga, Mussa; Masanja, Irene M; Peterson, David S; Udhayakumar, Venkatachalam; Lucchi, Naomi W
2014-01-27
Accurate diagnosis of malaria infections remains challenging, especially in the identification of submicroscopic infections. New molecular diagnostic tools that are inexpensive, sensitive enough to detect low-level infections and suitable in laboratory settings of resource-limited countries are required for malaria control and elimination programmes. Here the diagnostic potential of a recently developed photo-induced electron transfer fluorogenic primer (PET) real-time polymerase chain reaction (PCR) called PET-PCR was investigated. This study aimed to (i) evaluate the use of this assay as a method for the detection of both Plasmodium falciparum and other Plasmodium species infections in a developing country's diagnostic laboratory; and, (ii) determine the assay's sensitivity and specificity compared to a nested 18S rRNA PCR. Samples used in this study were obtained from a previous study conducted in the region of Iringa, Tanzania. A total of 303 samples from eight health facilities in Tanzania were utilized for this evaluation. All samples were screened using the multiplex PET-PCR assay designed to detect Plasmodium genus and P. falciparum initially in laboratory in Tanzania and then repeated at a reference laboratory at the CDC in the USA. Microscopy data was available for all the 303 samples. A subset of the samples were tested in a blinded fashion to find the sensitivity and specificity of the PET-PCR compared to the nested 18S rRNA PCR. Compared to microscopy, the PET-PCR assay was 59% more sensitive in detecting P. falciparum infections. The observed sensitivity and specificity were 100% (95% confidence interval (CI0.95) = 94-100%) and (CI0.95 = 96-100%), respectively, for the PET-PCR assay when compared to nested 18S rRNA PCR. When compared to 18S rRNA PCR, microscopy had a low sensitivity of 40% (CI0.95 = 23-61%) and specificity of 100% (CI0.95 = 96-100%). The PET-PCR results performed in the field laboratory in Tanzania were in 100% concordance with the results obtained at the reference laboratory in the USA. The PET-PCR is a new molecular diagnostic tool with similar performance characteristics as commonly used PCR methods that is less expensive, easy to use, and amiable to large scale-surveillance studies in developing country settings.
El Bali, Latifa; Diman, Aurélie; Bernard, Alfred; Roosens, Nancy H. C.; De Keersmaecker, Sigrid C. J.
2014-01-01
Human genomic DNA extracted from urine could be an interesting tool for large-scale public health studies involving characterization of genetic variations or DNA biomarkers as a result of the simple and noninvasive collection method. These studies, involving many samples, require a rapid, easy, and standardized extraction protocol. Moreover, for practicability, there is a necessity to collect urine at a moment different from the first void and to store it appropriately until analysis. The present study compared seven commercial kits to select the most appropriate urinary human DNA extraction procedure for epidemiological studies. DNA yield has been determined using different quantification methods: two classical, i.e., NanoDrop and PicoGreen, and two species-specific real-time quantitative (q)PCR assays, as DNA extracted from urine contains, besides human, microbial DNA also, which largely contributes to the total DNA yield. In addition, the kits giving a good yield were also tested for the presence of PCR inhibitors. Further comparisons were performed regarding the sampling time and the storage conditions. Finally, as a proof-of-concept, an important gene related to smoking has been genotyped using the developed tools. We could select one well-performing kit for the human DNA extraction from urine suitable for molecular diagnostic real-time qPCR-based assays targeting genetic variations, applicable to large-scale studies. In addition, successful genotyping was possible using DNA extracted from urine stored at −20°C for several months, and an acceptable yield could also be obtained from urine collected at different moments during the day, which is particularly important for public health studies. PMID:25365790
Stothard, J Russell; Adams, Emily
2014-12-01
There are many reasons why detection of parasites of medical and veterinary importance is vital and where novel diagnostic and surveillance tools are required. From a medical perspective alone, these originate from a desire for better clinical management and rational use of medications. Diagnosis can be at the individual-level, at close to patient settings in testing a clinical suspicion or at the community-level, perhaps in front of a computer screen, in classification of endemic areas and devising appropriate control interventions. Thus diagnostics for parasitic diseases has a broad remit as parasites are not only tied with their definitive hosts but also in some cases with their vectors/intermediate hosts. Application of current diagnostic tools and decision algorithms in sustaining control programmes, or in elimination settings, can be problematic and even ill-fitting. For example in resource-limited settings, are current diagnostic tools sufficiently robust for operational use at scale or are they confounded by on-the-ground realities; are the diagnostic algorithms underlying public health interventions always understood and well-received within communities which are targeted for control? Within this Special Issue (SI) covering a variety of diseases and diagnostic settings some answers are forthcoming. An important theme, however, throughout the SI is to acknowledge that cross-talk and continuous feedback between development and application of diagnostic tests is crucial if they are to be used effectively and appropriately.
NASA Technical Reports Server (NTRS)
Meyer, Scott A.; Bershader, Daniel; Sharma, Surendra P.; Deiwert, George S.
1996-01-01
Absorption measurements with a tunable vacuum ultraviolet light source have been proposed as a concentration diagnostic for atomic oxygen, and the viability of this technique is assessed in light of recent measurements. The instrumentation, as well as initial calibration measurements, have been reported previously. We report here additional calibration measurements performed to study the resonance broadening line shape for atomic oxygen. The application of this diagnostic is evaluated by considering the range of suitable test conditions and requirements, and by identifying issues that remain to be addressed.
Ibrahim, Sulaiman S; Riveron, Jacob M; Bibby, Jaclyn; Irving, Helen; Yunta, Cristina; Paine, Mark J I; Wondji, Charles S
2015-10-01
Scale up of Long Lasting Insecticide Nets (LLINs) has massively contributed to reduce malaria mortality across Africa. However, resistance to pyrethroid insecticides in malaria vectors threatens its continued effectiveness. Deciphering the detailed molecular basis of such resistance and designing diagnostic tools is critical to implement suitable resistance management strategies. Here, we demonstrated that allelic variation in two cytochrome P450 genes is the most important driver of pyrethroid resistance in the major African malaria vector Anopheles funestus and detected key mutations controlling this resistance. An Africa-wide polymorphism analysis of the duplicated genes CYP6P9a and CYP6P9b revealed that both genes are directionally selected with alleles segregating according to resistance phenotypes. Modelling and docking simulations predicted that resistant alleles were better metabolizers of pyrethroids than susceptible alleles. Metabolism assays performed with recombinant enzymes of various alleles confirmed that alleles from resistant mosquitoes had significantly higher activities toward pyrethroids. Additionally, transgenic expression in Drosophila showed that flies expressing resistant alleles of both genes were significantly more resistant to pyrethroids compared with those expressing the susceptible alleles, indicating that allelic variation is the key resistance mechanism. Furthermore, site-directed mutagenesis and functional analyses demonstrated that three amino acid changes (Val109Ile, Asp335Glu and Asn384Ser) from the resistant allele of CYP6P9b were key pyrethroid resistance mutations inducing high metabolic efficiency. The detection of these first DNA markers of metabolic resistance to pyrethroids allows the design of DNA-based diagnostic tools to detect and track resistance associated with bednets scale up, which will improve the design of evidence-based resistance management strategies.
Ibrahim, Sulaiman S.; Riveron, Jacob M.; Bibby, Jaclyn; Irving, Helen; Yunta, Cristina; Paine, Mark J. I.; Wondji, Charles S.
2015-01-01
Scale up of Long Lasting Insecticide Nets (LLINs) has massively contributed to reduce malaria mortality across Africa. However, resistance to pyrethroid insecticides in malaria vectors threatens its continued effectiveness. Deciphering the detailed molecular basis of such resistance and designing diagnostic tools is critical to implement suitable resistance management strategies. Here, we demonstrated that allelic variation in two cytochrome P450 genes is the most important driver of pyrethroid resistance in the major African malaria vector Anopheles funestus and detected key mutations controlling this resistance. An Africa-wide polymorphism analysis of the duplicated genes CYP6P9a and CYP6P9b revealed that both genes are directionally selected with alleles segregating according to resistance phenotypes. Modelling and docking simulations predicted that resistant alleles were better metabolizers of pyrethroids than susceptible alleles. Metabolism assays performed with recombinant enzymes of various alleles confirmed that alleles from resistant mosquitoes had significantly higher activities toward pyrethroids. Additionally, transgenic expression in Drosophila showed that flies expressing resistant alleles of both genes were significantly more resistant to pyrethroids compared with those expressing the susceptible alleles, indicating that allelic variation is the key resistance mechanism. Furthermore, site-directed mutagenesis and functional analyses demonstrated that three amino acid changes (Val109Ile, Asp335Glu and Asn384Ser) from the resistant allele of CYP6P9b were key pyrethroid resistance mutations inducing high metabolic efficiency. The detection of these first DNA markers of metabolic resistance to pyrethroids allows the design of DNA-based diagnostic tools to detect and track resistance associated with bednets scale up, which will improve the design of evidence-based resistance management strategies. PMID:26517127
Chip-Based Sensors for Disease Diagnosis
NASA Astrophysics Data System (ADS)
Fang, Zhichao
Nucleic acid analysis is one of the most important disease diagnostic approaches in medical practice, and has been commonly used in cancer biomarker detection, bacterial speciation and many other fields in laboratory. Currently, the application of powerful research methods for genetic analysis, including the polymerase chain reaction (PCR), DNA sequencing, and gene expression profiling using fluorescence microarrays, are not widely used in hospitals and extended-care units due to high-cost, long detection times, and extensive sample preparation. Bioassays, especially chip-based electrochemical sensors, may be suitable for the next generation of rapid, sensitive, and multiplexed detection tools. Herein, we report three different microelectrode platforms with capabilities enabled by nano- and microtechnology: nanoelectrode ensembles (NEEs), nanostructured microelectrodes (NMEs), and hierarchical nanostructured microelectrodes (HNMEs), all of which are able to directly detect unpurified RNA in clinical samples without enzymatic amplification. Biomarkers that are cancer and infectious disease relevant to clinical medicine were chosen to be the targets. Markers were successfully detected with clinically-relevant sensitivity. Using peptide nucleic acids (PNAs) as probes and an electrocatalytic reporter system, NEEs were able to detect prostate cancer-related gene fusions in tumor tissue samples with 100 ng of RNA. The development of NMEs improved the sensitivity of the assay further to 10 aM of DNA target, and multiplexed detection of RNA sequences of different prostate cancer-related gene fusion types was achieved on the chip-based NMEs platform. An HNMEs chip integrated with a bacterial lysis device was able to detect as few as 25 cfu bacteria in 30 minutes and monitor the detection in real time. Bacterial detection could also be performed in neat urine samples. The development of these versatile clinical diagnostic tools could be extended to the detection of various cancers, genetic, and infectious diseases.
Identification of structural proteins of koi herpesvirus.
Fuchs, Walter; Granzow, Harald; Dauber, Malte; Fichtner, Dieter; Mettenleiter, Thomas C
2014-12-01
As a prerequisite for development of improved vaccines and diagnostic tools for control of the fish pathogen koi herpesvirus, or cyprinid herpesvirus 3 (CyHV-3), we have started to identify putative viral envelope and capsid proteins. The complete or partial CyHV-3 open reading frames ORF25, ORF65, ORF92, ORF99, ORF136, ORF138, ORF146, ORF148, and ORF149 were expressed as bacterial fusion proteins, which were then used for preparation of monospecific rabbit antisera. All of the sera that were obtained detected their target proteins in cells transfected with the corresponding eukaryotic expression plasmids. However, only the type I membrane proteins pORF25, pORF65, pORF99, pORF136 and pORF149 and the major capsid protein pORF92 were sufficiently abundant and immunogenic to permit unambiguous detection in CyHV-3-infected cells. In indirect immunofluorescence tests (IIFT), sera from naturally or experimentally CyHV-3-infected carp and koi predominantly reacted with cells transfected with expression plasmids encoding pORF25, pORF65, pORF148, and pORF149, which represent a family of related CyHV-3 membrane proteins. Moreover, several neutralizing monoclonal antibodies raised against CyHV-3 virions proved to be specific for pORF149 in IIFT of transfected cells and in immunoelectron microscopic analysis of CyHV-3 particles. Since pORF149 appears to be an immunorelevant envelope protein of CyHV-3, a recombinant baculovirus was generated for its expression in insect cells, and pORF149 was shown to be incorporated into pseudotyped baculovirus particles, which might be suitable as diagnostic tools or subunit vaccines.
Formenti, F.; Chen, R.; McPeak, H.; Murison, P. J.; Matejovic, M.; Hahn, C. E. W.; Farmery, A. D.
2015-01-01
Background There is considerable interest in oxygen partial pressure (Po2) monitoring in physiology, and in tracking Po2 changes dynamically when it varies rapidly. For example, arterial Po2 (PaO2) can vary within the respiratory cycle in cyclical atelectasis (CA), where PaO2 is thought to increase and decrease during inspiration and expiration, respectively. A sensor that detects these PaO2 oscillations could become a useful diagnostic tool of CA during acute respiratory distress syndrome (ARDS). Methods We developed a fibreoptic Po2 sensor (<200 µm diameter), suitable for human use, that has a fast response time, and can measure Po2 continuously in blood. By altering the inspired fraction of oxygen (FIO2) from 21 to 100% in four healthy animal models, we determined the linearity of the sensor's signal over a wide range of PaO2 values in vivo. We also hypothesized that the sensor could measure rapid intra-breath PaO2 oscillations in a large animal model of ARDS. Results In the healthy animal models, PaO2 responses to changes in FIO2 were in agreement with conventional intermittent blood-gas analysis (n=39) for a wide range of PaO2 values, from 10 to 73 kPa. In the animal lavage model of CA, the sensor detected PaO2 oscillations, also at clinically relevant PaO2 levels close to 9 kPa. Conclusions We conclude that these fibreoptic PaO2 sensors have the potential to become a diagnostic tool for CA in ARDS. PMID:25631471
NASA Astrophysics Data System (ADS)
Kucera, P. A.; Burek, T.; Halley-Gotway, J.
2015-12-01
NCAR's Joint Numerical Testbed Program (JNTP) focuses on the evaluation of experimental forecasts of tropical cyclones (TCs) with the goal of developing new research tools and diagnostic evaluation methods that can be transitioned to operations. Recent activities include the development of new TC forecast verification methods and the development of an adaptable TC display and diagnostic system. The next generation display and diagnostic system is being developed to support evaluation needs of the U.S. National Hurricane Center (NHC) and broader TC research community. The new hurricane display and diagnostic capabilities allow forecasters and research scientists to more deeply examine the performance of operational and experimental models. The system is built upon modern and flexible technology that includes OpenLayers Mapping tools that are platform independent. The forecast track and intensity along with associated observed track information are stored in an efficient MySQL database. The system provides easy-to-use interactive display system, and provides diagnostic tools to examine forecast track stratified by intensity. Consensus forecasts can be computed and displayed interactively. The system is designed to display information for both real-time and for historical TC cyclones. The display configurations are easily adaptable to meet the needs of the end-user preferences. Ongoing enhancements include improving capabilities for stratification and evaluation of historical best tracks, development and implementation of additional methods to stratify and compute consensus hurricane track and intensity forecasts, and improved graphical display tools. The display is also being enhanced to incorporate gridded forecast, satellite, and sea surface temperature fields. The presentation will provide an overview of the display and diagnostic system development and demonstration of the current capabilities.
Rutstein, Sarah E; Ananworanich, Jintanat; Fidler, Sarah; Johnson, Cheryl; Sanders, Eduard J; Sued, Omar; Saez-Cirion, Asier; Pilcher, Christopher D; Fraser, Christophe; Cohen, Myron S; Vitoria, Marco; Doherty, Meg; Tucker, Joseph D
2017-06-28
The unchanged global HIV incidence may be related to ignoring acute HIV infection (AHI). This scoping review examines diagnostic, clinical, and public health implications of identifying and treating persons with AHI. We searched PubMed, in addition to hand-review of key journals identifying research pertaining to AHI detection and treatment. We focused on the relative contribution of AHI to transmission and the diagnostic, clinical, and public health implications. We prioritized research from low- and middle-income countries (LMICs) published in the last fifteen years. Extensive AHI research and limited routine AHI detection and treatment have begun in LMIC. Diagnostic challenges include ease-of-use, suitability for application and distribution in LMIC, and throughput for high-volume testing. Risk score algorithms have been used in LMIC to screen for AHI among individuals with behavioural and clinical characteristics more often associated with AHI. However, algorithms have not been implemented outside research settings. From a clinical perspective, there are substantial immunological and virological benefits to identifying and treating persons with AHI - evading the irreversible damage to host immune systems and seeding of viral reservoirs that occurs during untreated acute infection. The therapeutic benefits require rapid initiation of antiretrovirals, a logistical challenge in the absence of point-of-care testing. From a public health perspective, AHI diagnosis and treatment is critical to: decrease transmission via viral load reduction and behavioural interventions; improve pre-exposure prophylaxis outcomes by avoiding treatment initiation for HIV-seronegative persons with AHI; and, enhance partner services via notification for persons recently exposed or likely transmitting. There are undeniable clinical and public health benefits to AHI detection and treatment, but also substantial diagnostic and logistical barriers to implementation and scale-up. Effective early ART initiation may be critical for HIV eradication efforts, but widespread use in LMIC requires simple and accurate diagnostic tools. Implementation research is critical to facilitate sustainable integration of AHI detection and treatment into existing health systems and will be essential for prospective evaluation of testing algorithms, point-of-care diagnostics, and efficacious and effective first-line regimens.
Rutstein, Sarah E.; Ananworanich, Jintanat; Fidler, Sarah; Johnson, Cheryl; Sanders, Eduard J.; Sued, Omar; Saez-Cirion, Asier; Pilcher, Christopher D.; Fraser, Christophe; Cohen, Myron S.; Vitoria, Marco; Doherty, Meg; Tucker, Joseph D.
2017-01-01
Abstract Introduction: The unchanged global HIV incidence may be related to ignoring acute HIV infection (AHI). This scoping review examines diagnostic, clinical, and public health implications of identifying and treating persons with AHI. Methods: We searched PubMed, in addition to hand-review of key journals identifying research pertaining to AHI detection and treatment. We focused on the relative contribution of AHI to transmission and the diagnostic, clinical, and public health implications. We prioritized research from low- and middle-income countries (LMICs) published in the last fifteen years. Results and Discussion: Extensive AHI research and limited routine AHI detection and treatment have begun in LMIC. Diagnostic challenges include ease-of-use, suitability for application and distribution in LMIC, and throughput for high-volume testing. Risk score algorithms have been used in LMIC to screen for AHI among individuals with behavioural and clinical characteristics more often associated with AHI. However, algorithms have not been implemented outside research settings. From a clinical perspective, there are substantial immunological and virological benefits to identifying and treating persons with AHI – evading the irreversible damage to host immune systems and seeding of viral reservoirs that occurs during untreated acute infection. The therapeutic benefits require rapid initiation of antiretrovirals, a logistical challenge in the absence of point-of-care testing. From a public health perspective, AHI diagnosis and treatment is critical to: decrease transmission via viral load reduction and behavioural interventions; improve pre-exposure prophylaxis outcomes by avoiding treatment initiation for HIV-seronegative persons with AHI; and, enhance partner services via notification for persons recently exposed or likely transmitting. Conclusions: There are undeniable clinical and public health benefits to AHI detection and treatment, but also substantial diagnostic and logistical barriers to implementation and scale-up. Effective early ART initiation may be critical for HIV eradication efforts, but widespread use in LMIC requires simple and accurate diagnostic tools. Implementation research is critical to facilitate sustainable integration of AHI detection and treatment into existing health systems and will be essential for prospective evaluation of testing algorithms, point-of-care diagnostics, and efficacious and effective first-line regimens. PMID:28691435
Using the arthroscopic surgery skill evaluation tool as a pass-fail examination.
Koehler, Ryan J; Nicandri, Gregg T
2013-12-04
Examination of arthroscopic skill requires evaluation tools that are valid and reliable with clear criteria for passing. The Arthroscopic Surgery Skill Evaluation Tool was developed as a video-based assessment of technical skill with criteria for passing established by a panel of experts. The purpose of this study was to test the validity and reliability of the Arthroscopic Surgery Skill Evaluation Tool as a pass-fail examination of arthroscopic skill. Twenty-eight residents and two sports medicine faculty members were recorded performing diagnostic knee arthroscopy on a left and right cadaveric specimen in our arthroscopic skills laboratory. Procedure videos were evaluated with use of the Arthroscopic Surgery Skill Evaluation Tool by two raters blind to subject identity. Subjects were considered to pass the Arthroscopic Surgery Skill Evaluation Tool when they attained scores of ≥ 3 on all eight assessment domains. The raters agreed on a pass-fail rating for fifty-five of sixty videos rated with an interclass correlation coefficient value of 0.83. Ten of thirty participants were assigned passing scores by both raters for both diagnostic arthroscopies performed in the laboratory. Receiver operating characteristic analysis demonstrated that logging more than eighty arthroscopic cases or performing more than thirty-five arthroscopic knee cases was predictive of attaining a passing Arthroscopic Surgery Skill Evaluation Tool score on both procedures performed in the laboratory. The Arthroscopic Surgery Skill Evaluation Tool is valid and reliable as a pass-fail examination of diagnostic arthroscopy of the knee in the simulation laboratory. This study demonstrates that the Arthroscopic Surgery Skill Evaluation Tool may be a useful tool for pass-fail examination of diagnostic arthroscopy of the knee in the simulation laboratory. Further study is necessary to determine whether the Arthroscopic Surgery Skill Evaluation Tool can be used for the assessment of multiple arthroscopic procedures and whether it can be used to evaluate arthroscopic procedures performed in the operating room.
Object oriented fault diagnosis system for space shuttle main engine redlines
NASA Technical Reports Server (NTRS)
Rogers, John S.; Mohapatra, Saroj Kumar
1990-01-01
A great deal of attention has recently been given to Artificial Intelligence research in the area of computer aided diagnostics. Due to the dynamic and complex nature of space shuttle red-line parameters, a research effort is under way to develop a real time diagnostic tool that will employ historical and engineering rulebases as well as a sensor validity checking. The capability of AI software development tools (KEE and G2) will be explored by applying object oriented programming techniques in accomplishing the diagnostic evaluation.
A Review and Comparison of Diagnostic Instruments to Identify Students' Misconceptions in Science
ERIC Educational Resources Information Center
Gurel, Derya Kaltakci; Eryilmaz, Ali; McDermott, Lillian Christie
2015-01-01
Different diagnostic tools have been developed and used by researchers to identify students' conceptions. The present study aimed to provide an overview of the common diagnostic instruments in science to assess students' misconceptions. Also the study provides a brief comparison of these common diagnostic instruments with their strengths and…
WE-AB-206-00: Diagnostic QA/QC Hands-On Workshop
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
The involvement of medical physicists in diagnostic ultrasound imaging service is increasing due to QC and accreditation requirements. The goal of this ultrasound hands-on workshop is to demonstrate quality control (QC) testing in diagnostic ultrasound and to provide updates in ACR ultrasound accreditation requirements. The first half of this workshop will include two presentations reviewing diagnostic ultrasound QA/QC and ACR ultrasound accreditation requirements. The second half of the workshop will include live demonstrations of basic QC tests. An array of ultrasound testing phantoms and ultrasound scanners will be available for attendees to learn diagnostic ultrasound QC in a hands-on environmentmore » with live demonstrations and on-site instructors. The targeted attendees are medical physicists in diagnostic imaging. Learning Objectives: Gain familiarity with common elements of a QA/QC program for diagnostic ultrasound imaging dentify QC tools available for testing diagnostic ultrasound systems and learn how to use these tools Learn ACR ultrasound accreditation requirements Jennifer Walter is an employee of American College of Radiology on Ultrasound Accreditation.« less
CLASSIFICATION FRAMEWORK FOR DIAGNOSTICS RESEARCH
The goal of Diagnostics Research is to provide tools to simplify diagnosis of the causes of biological impairment, in support of State and Tribe 303(d) impaired waters lists. The Diagnostics Workgroup has developed conceptual models for four major aquatic stressors that cause im...
Ciurzyński, Michał; Kurzyna, Marcin; Kopeć, Grzegorz; Błaszczak, Piotr; Chrzanowski, Łukasz; Kamiński, Karol; Mizia-Stec, Katarzyna; Mularek-Kubzdela, Tatiana; Mroczek, Ewa; Biederman, Andrzej; Pruszczyk, Piotr; Torbicki, Adam
2017-01-01
Both pharmacological and invasive treatment of chronic thromboembolic pulmonary hypertension (CTEPH) is now available in Poland and the awareness of the disease among physicians is growing. Thus, the Polish Cardiac Society's Working Group on Pulmonary Circulation in cooperation with independent experts in this field, have launched the statement on algorithm to guide a CTEPH diagnosis in patients with previous acute pulmonary embolism (APE). In Poland, every year this disease affects about 250 patients. CTEPH should be suspected in individuals after APE with dyspnea, despite at least 3 months period of effective anticoagulation, particularly when specified risk factors are present. Echocardiography is a main screening tool. The authors suggest that a diagnostic process of patients with significant clinical suspicion of CTEPH and right ventricle overload in echocardiography should be performed in reference centres. The document contains a list of Polish centres diagnosing patients with suspected CTEPH. Pulmonary scintigraphy is a safe and highly sensitive screening test for CTEPH. Multi-detector computed tomography with precise detection of thromboembolic residues in pulmonary circulation is important for planning of pulmonary endarterectomy. Right heart catheterisation definitely confirms the presence of pulmonary hypertension and direct pulmonary angiography allows for identification of lesions suitable for thromboendarterectomy or pulmonary balloon angioplasty. In this document a diagnostic algorithm in patients with suspected CTEPH is also proposed. With individualised sequential diagnostic strategy each patient can be finally qualified for a particular mode of therapy by dedicated CTEPH Heart Team. Moreover the document contains short information for the primary care physician about the management of patients after APE.
A novel modification of the Turing test for artificial intelligence and robotics in healthcare.
Ashrafian, Hutan; Darzi, Ara; Athanasiou, Thanos
2015-03-01
The increasing demands of delivering higher quality global healthcare has resulted in a corresponding expansion in the development of computer-based and robotic healthcare tools that rely on artificially intelligent technologies. The Turing test was designed to assess artificial intelligence (AI) in computer technology. It remains an important qualitative tool for testing the next generation of medical diagnostics and medical robotics. Development of quantifiable diagnostic accuracy meta-analytical evaluative techniques for the Turing test paradigm. Modification of the Turing test to offer quantifiable diagnostic precision and statistical effect-size robustness in the assessment of AI for computer-based and robotic healthcare technologies. Modification of the Turing test to offer robust diagnostic scores for AI can contribute to enhancing and refining the next generation of digital diagnostic technologies and healthcare robotics. Copyright © 2014 John Wiley & Sons, Ltd.
NASA Technical Reports Server (NTRS)
Misra, Prabhakar; She, Yong-Bo; Zhu, Xin-Ming; King, Michael
1997-01-01
Combustion studies under both normal gravity and microgravity conditions depend a great deal on the availability and quality of the diagnostic systems used for such investigations. Microgravity phenomena are specially susceptible to even small perturbations and therefore non-intrusive diagnostic techniques are of paramount importance for successful understanding of reduced-gravity combustion phenomena. Several non-intrusive diagnostic techniques are available for probing and delineating normal as well as reduced gravity combustion processes, such as Rayleigh scattering, Raman scattering, Mie scattering, velocimetry, interferometric and Schlieren techniques, emission and laser-induced fluorescence (LIF) spectroscopy. Our approach is to use the LIF technique as a non-intrusive diagnostic tool for the study of combustion-associated free radicals and use the concomitant optogalvanic transitions to accomplish precise calibration of the laser wavelengths used for recording the excitation spectra of transient molecular species. In attempting to perform spectroscopic measurements on chemical intermediates, we have used conventional laser sources as well as new and novel platforms employing rare-earth doped solid-state lasers. Conventional (commercially available) sources of tunable UV laser radiation are extremely cumbersome and energy-consuming devices that are not very suitable for either in-space or in-flight (or microgravity drop tower) experiments. Traditional LIF sources of tunable UV laser radiation involve in addition to a pump laser (usually a Nd:YAG laser with an attached frequency-doubling stage), a tunable dye laser. In turn, the dye laser has to be provided with a dye circulation system and a subsequent stage for frequency-doubling of the dye laser radiation, together with a servo-tuning system (termed the 'Autotracker') to follow the wavelength changes and also an optical system (called the 'Frequency Separator') for separation of the emanating visible and UV beams. In contrast to this approach, we have devised an alternate arrangement for recording LIF excitation spectra of free radicals (following appropriate precursor fragmentation) that utilizes a tunable rare-earth doped solid state laser system with direct UV pumping. We have designed a compact and portable tunable UV laser system incorporating features necessary for both in-space and in-flight spectroscopy experiments. For the purpose of LIF excitation, we have developed an all-solid-state tunable UV laser that employs direct pumping of the solid-state UV-active medium employing UV harmonics from a Nd:YAG laser. An optical scheme with counterpropagating photolysis and excitation beams focused by suitable lenses into a reaction vacuum chamber was employed.
ERIC Educational Resources Information Center
Niessen, Maurice A. J.; Dingemans, Peter M. A. J.; van de Fliert, Reinaud; Becker, Hiske E.; Nieman, Dorien H.; Linszen, Don
2010-01-01
Providers of mental health services need tools to screen for acute psychosis and ultrahigh risk (UHR) for transition to psychosis in help-seeking individuals. In this study, the Eppendorf Schizophrenia Inventory (ESI) was examined as a screening tool and for its ability to correctly predict diagnostic group membership (e.g., help seeking, mild…
ERIC Educational Resources Information Center
McClary, LaKeisha M.; Bretz, Stacey Lowery
2012-01-01
The central goal of this study was to create a new diagnostic tool to identify organic chemistry students' alternative conceptions related to acid strength. Twenty years of research on secondary and college students' conceptions about acids and bases has shown that these important concepts are difficult for students to apply to qualitative problem…
Michaud, Ginette Y
2005-01-01
In the field of clinical laboratory medicine, standardization is aimed at increasing the trueness and reliability of measured values. Standardization relies on the use of written standards, reference measurement procedures and reference materials. These are important tools for the design and validation of new tests, and for establishing the metrological traceability of diagnostic assays. Their use supports the translation of research technologies into new diagnostic assays and leads to more rapid advances in science and medicine, as well as improvements in the quality of patient care. The various standardization tools are described, as are the procedures by which written standards, reference procedures and reference materials are developed. Recent efforts to develop standards for use in the field of molecular diagnostics are discussed. The recognition of standardization tools by the FDA and other regulatory authorities is noted as evidence of their important role in ensuring the safety and performance of in vitro diagnostic devices.
Case Report: SPECT/CT as the New Diagnostic Tool for Specific Wrist Pathology.
Linde, Musters; Ten Broek, M; Kraan, G A
2017-01-01
Single photon emission computed tomography has been introduced as a promising new diagnostic tool in orthopaedic pathology since the early 90'. Computed tomography, the combined with SPECT, gives insight in the specific sight of wrist pathology. Literature already supports introduction of SPECT/CT in wrist pathology, but clinical application is lagging. A 40yr old patient reported first in 2004 with persisting pain after a right distal radius fracture. Several diagnostics and operative interventions were performed, all unsuccessful. Because of the persisting pain a SPECT-CT was performed which showed a cyst in the hamate bone, which was successfully enucleated. The patient was finally pain free at recent follow-up. With a QDash-score of 43 and a PRW (H) E-DLV-score of 58/150. In this case report, SPECT/CT proved a very sensitive diagnostic tool for specific pathology of the wrist. It offered precise localisation and thereby the clinically suspected diagnosis was confirmed and the patient successfully treated.
Decker, Sebastian O.; Sigl, Annette; Grumaz, Christian; Stevens, Philip; Vainshtein, Yevhen; Zimmermann, Stefan; Weigand, Markus A.; Hofer, Stefan; Sohn, Kai; Brenner, Thorsten
2017-01-01
Fungi are of increasing importance in sepsis. However, culture-based diagnostic procedures are associated with relevant weaknesses. Therefore, culture- and next-generation sequencing (NGS)-based fungal findings as well as corresponding plasma levels of β-d-glucan, interferon gamma (INF-γ), tumor necrosis factor alpha (TNF-α), interleukin (IL)-2, -4, -6, -10, -17A, and mid-regional proadrenomedullin (MR-proADM) were evaluated in 50 septic patients at six consecutive time points within 28 days after sepsis onset. Furthermore, immune-response patterns during infections with Candida spp. were studied in a reconstituted human epithelium model. In total, 22% (n = 11) of patients suffered from a fungal infection. An NGS-based diagnostic approach appeared to be suitable for the identification of fungal pathogens in patients suffering from fungemia as well as in patients with negative blood cultures. Moreover, MR-proADM and IL-17A in plasma proved suitable for the identification of patients with a fungal infection. Using RNA-seq., adrenomedullin (ADM) was shown to be a target gene which is upregulated early after an epithelial infection with Candida spp. In summary, an NGS-based diagnostic approach was able to close the diagnostic gap of routinely used culture-based diagnostic procedures, which can be further facilitated by plasmatic measurements of MR-proADM and IL-17A. In addition, ADM was identified as an early target gene in response to epithelial infections with Candida spp. PMID:28820494
Integration of tablet technologies in the e-laboratory of cytology: a health technology assessment.
Giansanti, Daniele; Pochini, Marco; Giovagnoli, Maria Rosaria
2014-10-01
Although tablet systems are becoming a powerful technology, particularly useful in every application of medical imaging, to date no one has investigated the acceptance and performance of this technology in digital cytology. The specific aims of the work were (1) to design a health technology assessment (HTA) tool to assess, in terms of performance and acceptance, the introduction of tablet technologies (wearable, portable, and non portable) in the e-laboratories of cytology and (2) to test the tool in a first significant application of digital cytology. An HTA tool was proposed operating on a domain of five dimensions of investigation comprising the basic information of the product of digital cytology, the perceived subjective quality of images, the assessment of the virtual navigation on the e-slide, the assessment of the information and communication technologies features, and the diagnostic power. Six e-slides regarding studies of cervicovaginal cytology digitalized by means of an Aperio ( www.aperio.com ) scanner and uploaded onto the www.digitalslide.it Web site were used for testing the methodology on three different network connections. Three experts of cytology successfully tested the methodology on seven tablets found suitable for the study in their own standard configuration. Specific indexes furnished by the tool indicated both a high degree of performance and subjective acceptance of the investigated technology. The HTA tool thus could be useful to investigate new tablet technologies in digital cytology and furnish stakeholders with useful information that may help them make decisions involving the healthcare system. From a global point of view the study demonstrates the feasibility of using the tablet technology in digital cytology.
NASA Astrophysics Data System (ADS)
Hiwarkar, V. R.; Babitsky, V. I.; Silberschmidt, V. V.
2013-07-01
Numerous techniques are available for monitoring structural health. Most of these techniques are expensive and time-consuming. In this paper, vibration-based techniques are explored together with their use as diagnostic tools for structural health monitoring. Finite-element simulations are used to study the effect of material nonlinearity on dynamics of a cracked bar. Additionally, several experiments are performed to study the effect of vibro-impact behavior of crack on its dynamics. It was observed that a change in the natural frequency of the cracked bar due to crack-tip plasticity and vibro-impact behavior linked to interaction of crack faces, obtained from experiments, led to generation of higher harmonics; this can be used as a diagnostic tool for structural health monitoring.
Applications and Methods for Continuous Monitoring of Physiological Chemistry
2016-02-04
product and test platform to verify the performance characteristics of the enzymes when used in diagnostic device fabrication. 1.3 Results This...project had three primary objectives: 1. Engineer a cortisol oxidase enzyme suitable for use in diagnostic devices 2. Large scale production and...for both animal and human use , and for direct sale to other entities to manufacture biosensors and other products for human monitoring. The enzymes
Advances in Alzheimer's Diagnosis and Therapy: The Implications of Nanotechnology.
Hajipour, Mohammad Javad; Santoso, Michelle R; Rezaee, Farhad; Aghaverdi, Haniyeh; Mahmoudi, Morteza; Perry, George
2017-10-01
Alzheimer's disease (AD) is a type of dementia that causes major issues for patients' memory, thinking, and behavior. Despite efforts to advance AD diagnostic and therapeutic tools, AD remains incurable due to its complex and multifactorial nature and lack of effective diagnostics/therapeutics. Nanoparticles (NPs) have demonstrated the potential to overcome the challenges and limitations associated with traditional diagnostics/therapeutics. Nanotechnology is now offering new tools and insights to advance our understanding of AD and eventually may offer new hope to AD patients. Here, we review the key roles of nanotechnologies in the recent literature, in both diagnostic and therapeutic aspects of AD, and discuss how these achievements may improve patient prognosis and quality of life. Copyright © 2017 Elsevier Ltd. All rights reserved.
Szentiks, C A; Tsangaras, K; Abendroth, B; Scheuch, M; Stenglein, M D; Wohlsein, P; Heeger, F; Höveler, R; Chen, W; Sun, W; Damiani, A; Nikolin, V; Gruber, A D; Grobbel, M; Kalthoff, D; Höper, D; Czirják, G Á; Derisi, J; Mazzoni, C J; Schüle, A; Aue, A; East, M L; Hofer, H; Beer, M; Osterrieder, N; Greenwood, A D
2014-05-01
This report describes three possibly related incidences of encephalitis, two of them lethal, in captive polar bears (Ursus maritimus). Standard diagnostic methods failed to identify pathogens in any of these cases. A comprehensive, three-stage diagnostic 'pipeline' employing both standard serological methods and new DNA microarray and next generation sequencing-based diagnostics was developed, in part as a consequence of this initial failure. This pipeline approach illustrates the strengths, weaknesses and limitations of these tools in determining pathogen caused deaths in non-model organisms such as wildlife species and why the use of a limited number of diagnostic tools may fail to uncover important wildlife pathogens. Copyright © 2013 Elsevier Ltd. All rights reserved.
Emerging applications of fluorescence spectroscopy in medical microbiology field.
Shahzad, Aamir; Köhler, Gottfried; Knapp, Martin; Gaubitzer, Erwin; Puchinger, Martin; Edetsberger, Michael
2009-11-26
There are many diagnostic techniques and methods available for diagnosis of medically important microorganisms like bacteria, viruses, fungi and parasites. But, almost all these techniques and methods have some limitations or inconvenience. Most of these techniques are laborious, time consuming and with chances of false positive or false negative results. It warrants the need of a diagnostic technique which can overcome these limitations and problems. At present, there is emerging trend to use Fluorescence spectroscopy as a diagnostic as well as research tool in many fields of medical sciences. Here, we will critically discuss research studies which propose that Fluorescence spectroscopy may be an excellent diagnostic as well as excellent research tool in medical microbiology field with high sensitivity and specificity.
Herrera, Sabina; Husain, Shahid
2018-05-21
The diagnosis of invasive aspergillosis remains challenging in solid organ transplants in general, and in lung transplant recipients, in particular, because of colonization. Lung transplant recipients may be over treated with antifungal drugs because of the lack of appropriate diagnostic tools. A review of the new developments of diagnostic tools and whether this help distinguishing colonization from invasive disease is presented. Efforts are being made to develop new tools that will allow us to identify which patients will develop IPA, and those who will be able to control the disease.
A defect-driven diagnostic method for machine tool spindles
Vogl, Gregory W.; Donmez, M. Alkan
2016-01-01
Simple vibration-based metrics are, in many cases, insufficient to diagnose machine tool spindle condition. These metrics couple defect-based motion with spindle dynamics; diagnostics should be defect-driven. A new method and spindle condition estimation device (SCED) were developed to acquire data and to separate system dynamics from defect geometry. Based on this method, a spindle condition metric relying only on defect geometry is proposed. Application of the SCED on various milling and turning spindles shows that the new approach is robust for diagnosing the machine tool spindle condition. PMID:28065985
Using urban forest assessment tools to model bird habitat potential
Lerman, Susannah B.; Nislow, Keith H.; Nowak, David J.; DeStefano, Stephen; King, David I.; Jones-Farrand, D. Todd
2014-01-01
The alteration of forest cover and the replacement of native vegetation with buildings, roads, exotic vegetation, and other urban features pose one of the greatest threats to global biodiversity. As more land becomes slated for urban development, identifying effective urban forest wildlife management tools becomes paramount to ensure the urban forest provides habitat to sustain bird and other wildlife populations. The primary goal of this study was to integrate wildlife suitability indices to an existing national urban forest assessment tool, i-Tree. We quantified available habitat characteristics of urban forests for ten northeastern U.S. cities, and summarized bird habitat relationships from the literature in terms of variables that were represented in the i-Tree datasets. With these data, we generated habitat suitability equations for nine bird species representing a range of life history traits and conservation status that predicts the habitat suitability based on i-Tree data. We applied these equations to the urban forest datasets to calculate the overall habitat suitability for each city and the habitat suitability for different types of land-use (e.g., residential, commercial, parkland) for each bird species. The proposed habitat models will help guide wildlife managers, urban planners, and landscape designers who require specific information such as desirable habitat conditions within an urban management project to help improve the suitability of urban forests for birds.
Cone Beam Computed Tomography-Dawn of A New Imaging Modality in Orthodontics
Mamatha, J; Chaitra, K R; Paul, Renji K; George, Merin; Anitha, J; Khanna, Bharti
2015-01-01
Today, we are in a world of innovations, and there are various diagnostics aids that help to take a decision regarding treatment in a well-planned way. Cone beam computed tomography (CBCT) has been a vital tool for imaging diagnostic tool in orthodontics. This article reviews case reports during orthodontic treatment and importance of CBCT during the treatment evaluation. PMID:26225116
A Structural Health Monitoring Software Tool for Optimization, Diagnostics and Prognostics
2011-01-01
A Structural Health Monitoring Software Tool for Optimization, Diagnostics and Prognostics Seth S . Kessler1, Eric B. Flynn2, Christopher T...technology more accessible, and commercially practical. 1. INTRODUCTION Currently successful laboratory non- destructive testing and monitoring...PROGRAM ELEMENT NUMBER 6. AUTHOR( S ) 5d. PROJECT NUMBER 5e. TASK NUMBER 5f. WORK UNIT NUMBER 7. PERFORMING ORGANIZATION NAME( S ) AND ADDRESS(ES
Douard, M C; Ardoin, C; Payri, L; Tarot, J P
1999-03-01
Implantable venous ports and Hickman central venous catheters are widely used in patients with cancer, blood disorders, or HIV infection, both for in-hospital care and at home. Infectious complications are among the common causes for readmission in these patients. The present review discusses the incidence, risk factors, and diagnostic tools for infectious complications associated with long-term venous access devices.
WE-AB-206-02: ACR Ultrasound Accreditation: Requirements and Pitfalls
DOE Office of Scientific and Technical Information (OSTI.GOV)
Walter, J.
The involvement of medical physicists in diagnostic ultrasound imaging service is increasing due to QC and accreditation requirements. The goal of this ultrasound hands-on workshop is to demonstrate quality control (QC) testing in diagnostic ultrasound and to provide updates in ACR ultrasound accreditation requirements. The first half of this workshop will include two presentations reviewing diagnostic ultrasound QA/QC and ACR ultrasound accreditation requirements. The second half of the workshop will include live demonstrations of basic QC tests. An array of ultrasound testing phantoms and ultrasound scanners will be available for attendees to learn diagnostic ultrasound QC in a hands-on environmentmore » with live demonstrations and on-site instructors. The targeted attendees are medical physicists in diagnostic imaging. Learning Objectives: Gain familiarity with common elements of a QA/QC program for diagnostic ultrasound imaging dentify QC tools available for testing diagnostic ultrasound systems and learn how to use these tools Learn ACR ultrasound accreditation requirements Jennifer Walter is an employee of American College of Radiology on Ultrasound Accreditation.« less
An evidence-based diagnostic classification system for low back pain
Vining, Robert; Potocki, Eric; Seidman, Michael; Morgenthal, A. Paige
2013-01-01
Introduction: While clinicians generally accept that musculoskeletal low back pain (LBP) can arise from specific tissues, it remains difficult to confirm specific sources. Methods: Based on evidence supported by diagnostic utility studies, doctors of chiropractic functioning as members of a research clinic created a diagnostic classification system, corresponding exam and checklist based on strength of evidence, and in-office efficiency. Results: The diagnostic classification system contains one screening category, two pain categories: Nociceptive, Neuropathic, one functional evaluation category, and one category for unknown or poorly defined diagnoses. Nociceptive and neuropathic pain categories are each divided into 4 subcategories. Conclusion: This article describes and discusses the strength of evidence surrounding diagnostic categories for an in-office, clinical exam and checklist tool for LBP diagnosis. The use of a standardized tool for diagnosing low back pain in clinical and research settings is encouraged. PMID:23997245
Geimer, Sabina Andersson
2013-02-01
This thesis addresses several aspects of glaucoma diagnostics from both a clinical and a screening perspective. New instruments for diagnosing glaucoma have been developed over the past years, but little information is available regarding their performance as screening methods and their usefulness in ordinary clinical practice. PURPOSE OF THE RESEARCH UNDERLYING THIS THESIS: The objectives of this research were as follows: to compare the accuracy of results of analysis of the optic nerve head (ONH) achieved by computerized imaging using the Heidelberg Retina Tomograph (HRT) and by subjective assessment performed by physicians with different degrees of experience of glaucoma (paper III); to evaluate the effect of a continuous medical education (CME) lecture on subjective assessment of the ONH for diagnosis of glaucoma (paper II); to investigate subjective assessment of perimetric test results by physicians with varying knowledge of glaucoma with a trained artificial neural network (ANN) and to compare the certainty of the classifications (paper IV); and to compare the diagnostic performance of time-domain Stratus optical coherence tomography (OCT) with that of spectral-domain Cirrus OCT (paper I), frequency doubling technology (FDT) screening perimetry and scanning laser polarimetry with the GDx variable corneal compensator (VCC) in a random population-based sample and in patients with glaucoma of varying disease severity. In evaluation of the ONH, use of the HRT statistical tools, Moorfields regression analysis (MRA) and the Glaucoma Probability Score (GPS) was compared with subjective assessment performed by 45 physicians. Optic nerve head images and photographs from 138 healthy and 97 glaucoma subjects were included. The sensitivity of MRA was higher (87-94%) than that of the average physician (62-82%), considerably greater than that of ophthalmologists with subspecialties other than glaucoma (53-77%) and non-significantly better than that of glaucoma experts (72-88%). Sensitivity achieved by GPS (79-93%) was also greater than that of the average physician. MRA correctly classified all eyes with advanced glaucomatous visual field defects, a result that was not achieved by GPS or even by the glaucoma experts. In eyes with small discs, MRA sensitivity (88%) was comparable with that of glaucoma experts (85%) and much better than that of GPS (50%). Also, the group comprising all physicians provided specificity (75-92%) similar to that of both MRA (69 - 86%) and GPS (72-94%) (Andersson et al. 2011a). A 1-hr CME lecture on ONH assessment led to a significant improvement in sensitivity (from 70% to 80%) and a significant decrease in uncertain assessments (from 22% to 13%), whereas specificity remained unchanged (68%) (Andersson et al. 2011b). A rise in sensitivity was seen in all subgroups of physicians, including glaucoma experts. Thirty physicians assessing standard automated perimetry (SAP) test results as Humphrey Field Analyzer single-field analysis printouts with full StatPac information from 99 patients with glaucoma and 66 healthy subjects were compared with a trained ANN regarding diagnostic performance. ANN reached significantly higher sensitivity (93%) than the average physician (83%), whereas specificity was similar for these two groups (91% and 90%, respectively). Diagnostic accuracy was similar among the different groups of physicians and seemingly rather independent of experience. Sensitivity ranged from 82% in the subgroup of other subspecialists to 87% in the glaucoma expert group, and specificity ranged from 88% among general ophthalmologists to 91% for glaucoma experts. The ANN attained certainty of classification that was in parity with that provided by the glaucoma experts and did not make any completely incorrect classifications of the visual fields (i.e. erroneous classifications were in the borderline zone) (Andersson et al. 2012). From a population-based randomly selected sample (n=308) of older subjects (aged ≥ 50 years) living in southern Sweden, 170 subjects underwent a comprehensive examination that included Stratus OCT, Cirrus OCT, an FDT screening programme and the GDx VCC. The same test protocol was applied to 138 randomized clinical patients with different stages of glaucoma. In the population-based sample, both Stratus and Cirrus OCT showed high diagnostic accuracy with area under the receiver-operating curve (aROC) values close to 1.0 (Bengtsson et al. 2012). Both OCT instruments correctly classified all of the clinical glaucoma patients with advanced disease. FDT screening showed high sensitivity (91%) but erroneously gave normal test results for some eyes with advanced disease. GDx VCC had lower sensitivity (73-92%) and also led to a large proportion of examinations with an atypical retardation pattern that is known to affect the diagnostic efficiency of this instrument. The HRT MRA performed better than most physicians and was consistent with the glaucoma experts. These results suggest that MRA can be a valuable tool for diagnosing glaucoma in ordinary practice, particularly when only a few glaucoma experts are available. Even though MRA provided 100% sensitivity in eyes with advanced glaucoma, it probably does not offer sufficient specificity to make it suitable as a screening method. Continuing medical education on ONH analysis had a small, but positive effect on diagnostic accuracy for glaucoma. An ANN trained to classify visual fields seemed to perform at least as well as most of the participating physicians, whose performances were remarkably similar regardless of their level of experience. This indicates that available tools for interpreting SAP findings are helpful in assessments of visual field test results. However, SAP is associated with learning effects (Heijl et al. 1989) that may entail low specificity for untrained subjects, and hence, it is not an ideal screening method for glaucoma. By comparison, the screening test of FDT is rapid and easy, but it is probably less suitable for screening purpose, because some eyes with advanced glaucoma were missed in this investigation. GDx VCC images for a relatively large number of eyes could not be analysed and is thus not appropriate for screening. The OCT instruments offer both high sensitivity and high specificity, and all eyes with advanced disease were correctly classified as glaucomatous in this evaluation. However, these instruments are still expensive and require special operator skills. Additional development to obtain OCT instrument that is more compact, easier to use and less expensive might render such tomography suitable as a screening tool for glaucoma. © 2013 The Author. Acta Ophthalmologica © 2013 Acta Ophthalmologica Scandinavica Foundation.
Screening and syndromic approaches to identify gonorrhea and chlamydial infection among women.
Sloan, N L; Winikoff, B; Haberland, N; Coggins, C; Elias, C
2000-03-01
The standard diagnostic tools to identify sexually transmitted infections are often expensive and have laboratory and infrastructure requirements that make them unavailable to family planning and primary health-care clinics in developing countries. Therefore, inexpensive, accessible tools that rely on symptoms, signs, and/or risk factors have been developed to identify and treat reproductive tract infections without the need for laboratory diagnostics. Studies were reviewed that used standard diagnostic tests to identify gonorrhea and cervical chlamydial infection among women and that provided adequate information about the usefulness of the tools for screening. Aggregation of the studies' results suggest that risk factors, algorithms, and risk scoring for syndromic management are poor indicators of gonorrhea and chlamydial infection in samples of both low and high prevalence and, consequently, are not effective mechanisms with which to identify or manage these conditions. The development and evaluation of other approaches to identify gonorrhea and chlamydial infections, including inexpensive and simple laboratory screening tools, periodic universal treatment, and other alternatives must be given priority.
[Intelligent systems tools in the diagnosis of acute coronary syndromes: A systemic review].
Sprockel, John; Tejeda, Miguel; Yate, José; Diaztagle, Juan; González, Enrique
2017-03-27
Acute myocardial infarction is the leading cause of non-communicable deaths worldwide. Its diagnosis is a highly complex task, for which modelling through automated methods has been attempted. A systematic review of the literature was performed on diagnostic tests that applied intelligent systems tools in the diagnosis of acute coronary syndromes. A systematic review of the literature is presented using Medline, Embase, Scopus, IEEE/IET Electronic Library, ISI Web of Science, Latindex and LILACS databases for articles that include the diagnostic evaluation of acute coronary syndromes using intelligent systems. The review process was conducted independently by 2 reviewers, and discrepancies were resolved through the participation of a third person. The operational characteristics of the studied tools were extracted. A total of 35 references met the inclusion criteria. In 22 (62.8%) cases, neural networks were used. In five studies, the performances of several intelligent systems tools were compared. Thirteen studies sought to perform diagnoses of all acute coronary syndromes, and in 22, only infarctions were studied. In 21 cases, clinical and electrocardiographic aspects were used as input data, and in 10, only electrocardiographic data were used. Most intelligent systems use the clinical context as a reference standard. High rates of diagnostic accuracy were found with better performance using neural networks and support vector machines, compared with statistical tools of pattern recognition and decision trees. Extensive evidence was found that shows that using intelligent systems tools achieves a greater degree of accuracy than some clinical algorithms or scales and, thus, should be considered appropriate tools for supporting diagnostic decisions of acute coronary syndromes. Copyright © 2017 Instituto Nacional de Cardiología Ignacio Chávez. Publicado por Masson Doyma México S.A. All rights reserved.
Dande, Payal; Samant, Purva
2018-01-01
Tuberculosis [TB] has afflicted numerous nations in the world. As per a report by the World Health Organization [WHO], an estimated 1.4 million TB deaths in 2015 and an additional 0.4 million deaths resulting from TB disease among people living with HIV, were observed. Most of the TB deaths can be prevented if it is detected at an early stage. The existing processes of diagnosis like blood tests or sputum tests are not only tedious but also take a long time for analysis and cannot differentiate between different drug resistant stages of TB. The need to find newer prompt methods for disease detection has been aided by the latest Artificial Intelligence [AI] tools. Artificial Neural Network [ANN] is one of the important tools that is being used widely in diagnosis and evaluation of medical conditions. This review aims at providing brief introduction to various AI tools that are used in TB detection and gives a detailed description about the utilization of ANN as an efficient diagnostic technique. The paper also provides a critical assessment of ANN and the existing techniques for their diagnosis of TB. Researchers and Practitioners in the field are looking forward to use ANN and other upcoming AI tools such as Fuzzy-logic, genetic algorithms and artificial intelligence simulation as a promising current and future technology tools towards tackling the global menace of Tuberculosis. Latest advancements in the diagnostic field include the combined use of ANN with various other AI tools like the Fuzzy-logic, which has led to an increase in the efficacy and specificity of the diagnostic techniques. Copyright © 2017 Elsevier Ltd. All rights reserved.
A systematic review of the PTSD Checklist's diagnostic accuracy studies using QUADAS.
McDonald, Scott D; Brown, Whitney L; Benesek, John P; Calhoun, Patrick S
2015-09-01
Despite the popularity of the PTSD Checklist (PCL) as a clinical screening test, there has been no comprehensive quality review of studies evaluating its diagnostic accuracy. A systematic quality assessment of 22 diagnostic accuracy studies of the English-language PCL using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS) assessment tool was conducted to examine (a) the quality of diagnostic accuracy studies of the PCL, and (b) whether quality has improved since the 2003 STAndards for the Reporting of Diagnostic accuracy studies (STARD) initiative regarding reporting guidelines for diagnostic accuracy studies. Three raters independently applied the QUADAS tool to each study, and a consensus among the 4 authors is reported. Findings indicated that although studies generally met standards in several quality areas, there is still room for improvement. Areas for improvement include establishing representativeness, adequately describing clinical and demographic characteristics of the sample, and presenting better descriptions of important aspects of test and reference standard execution. Only 2 studies met each of the 14 quality criteria. In addition, study quality has not appreciably improved since the publication of the STARD Statement in 2003. Recommendations for the improvement of diagnostic accuracy studies of the PCL are discussed. (c) 2015 APA, all rights reserved).
The next organizational challenge: finding and addressing diagnostic error.
Graber, Mark L; Trowbridge, Robert; Myers, Jennifer S; Umscheid, Craig A; Strull, William; Kanter, Michael H
2014-03-01
Although health care organizations (HCOs) are intensely focused on improving the safety of health care, efforts to date have almost exclusively targeted treatment-related issues. The literature confirms that the approaches HCOs use to identify adverse medical events are not effective in finding diagnostic errors, so the initial challenge is to identify cases of diagnostic error. WHY HEALTH CARE ORGANIZATIONS NEED TO GET INVOLVED: HCOs are preoccupied with many quality- and safety-related operational and clinical issues, including performance measures. The case for paying attention to diagnostic errors, however, is based on the following four points: (1) diagnostic errors are common and harmful, (2) high-quality health care requires high-quality diagnosis, (3) diagnostic errors are costly, and (4) HCOs are well positioned to lead the way in reducing diagnostic error. FINDING DIAGNOSTIC ERRORS: Current approaches to identifying diagnostic errors, such as occurrence screens, incident reports, autopsy, and peer review, were not designed to detect diagnostic issues (or problems of omission in general) and/or rely on voluntary reporting. The realization that the existing tools are inadequate has spurred efforts to identify novel tools that could be used to discover diagnostic errors or breakdowns in the diagnostic process that are associated with errors. New approaches--Maine Medical Center's case-finding of diagnostic errors by facilitating direct reports from physicians and Kaiser Permanente's electronic health record--based reports that detect process breakdowns in the followup of abnormal findings--are described in case studies. By raising awareness and implementing targeted programs that address diagnostic error, HCOs may begin to play an important role in addressing the problem of diagnostic error.
Student Interpretations of Diagnostic Feedback
ERIC Educational Resources Information Center
Doe, Christine
2015-01-01
Diagnostic assessment is increasingly being recognized as a potentially beneficial tool for teaching and learning (Jang, 2012). There have been calls in the research literature for students to receive diagnostic feedback and for researchers to investigate how such feedback is used by students. Therefore, this study examined how students…
A dynamic model of Flo-Tron flowmeters
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cichy, M.; Bossio, R.B.
1984-08-01
The optimization of diagnostic equipment for reciprocating both internal and external combustion engines are deeply affected by suitability of simulation models. One of the most attractive and difficult diagnostic aspect deals with the fuel instantaneous mass flow rate measurement. A new model of the dynamic simulation of the Flo-Tron flowmeter, whose working principle is based on the hydraulic Wheatstone's bridge is then presented, dealing with the state space equations and bond-graph method.
NASA Technical Reports Server (NTRS)
Mcgary, Michael C.
1988-01-01
The anticipated application of advanced turboprop propulsion systems is expected to increase the interior noise of future aircraft to unacceptably high levels. The absence of technically and economically feasible noise source-path diagnostic tools has been a prime obstacle in the development of efficient noise control treatments for propeller-driven aircraft. A new diagnostic method that permits the separation and prediction of the fully coherent airborne and structureborne components of the sound radiated by plates or thin shells has been developed. Analytical and experimental studies of the proposed method were performed on an aluminum plate. The results of the study indicate that the proposed method could be used in flight, and has fewer encumbrances than the other diagnostic tools currently available.
Khumrin, Piyapong; Ryan, Anna; Judd, Terry; Verspoor, Karin
2017-01-01
Computer-aided learning systems (e-learning systems) can help medical students gain more experience with diagnostic reasoning and decision making. Within this context, providing feedback that matches students' needs (i.e. personalised feedback) is both critical and challenging. In this paper, we describe the development of a machine learning model to support medical students' diagnostic decisions. Machine learning models were trained on 208 clinical cases presenting with abdominal pain, to predict five diagnoses. We assessed which of these models are likely to be most effective for use in an e-learning tool that allows students to interact with a virtual patient. The broader goal is to utilise these models to generate personalised feedback based on the specific patient information requested by students and their active diagnostic hypotheses.
Some diagnostic interpretations from railgun plasma profile experiments
NASA Astrophysics Data System (ADS)
Stainsby, D. F.; Bedford, A. J.
1984-03-01
Some aspects of a railgun experimental series to investigate plasma profiles are reviewed. Certain diagnostic records clearly show plasma leakage past the projectile, and correspondence between various in-bore events and muzzle voltage. A muzzle flash detector is shown to have a useful role as a plasma diagnostic tool.
Oral exfoliative cytology as a rapid diagnostic tool for paracoccidioidomycosis.
Talhari, Carolina; de Souza, João Vicente Braga; Parreira, Vilmar José; Reinel, Dieter; Talhari, Sinésio
2008-03-01
Paracoccidioidomycosis is a common deep mycosis in South America. It is caused by the dimorphic fungus Paracoccidioides brasiliensis. We report a case of a 47-year-old Brazilian man with oral lesions due to paracoccidioidomycosis, which was diagnosed by exfoliative cytology without any special staining. We highlight this diagnostic tool as a simple, low-cost, painless, non-invasive and fast method for the diagnosis of paracoccidioidomycosis.
ERIC Educational Resources Information Center
Boerma, Tessel; Chiat, Shula; Leseman, Paul; Timmermeister, Mona; Wijnen, Frank; Blom, Elma
2015-01-01
Purpose: This study evaluated a newly developed quasi-universal nonword repetition task (Q-U NWRT) as a diagnostic tool for bilingual children with language impairment (LI) who have Dutch as a 2nd language. The Q-U NWRT was designed to be minimally influenced by knowledge of 1 specific language in contrast to a language-specific NWRT with which it…
Drilling of optical glass with electroplated diamond tools
NASA Astrophysics Data System (ADS)
Wang, A. J.; Luan, C. G.; Yu, A. B.
2010-10-01
K9 optical glass drilling experiments were carried out. Bright nickel electroplated diamond tools with small slots and under heat treatment in different temperature were fabricated. Scan electro microscope was applied to analyze the wear of electroplated diamond tool. The material removal rate and grinding ratio were calculated. Machining quality was observed. Bond coating hardness was measured. The experimental results show that coolant is needed for the drilling processes of optical glasses. Heat treatment temperature of diamond tool has influence on wearability of diamond tool and grinding ratio. There were two wear types of electroplated diamond tool, diamond grit wear and bond wear. With the machining processes, wear of diamond grits included fracture, blunt and pull-out, and electroplated bond was gradually worn out. High material removal rates could be obtained by using diamond tool with suitable slot numbers. Bright nickel coating bond presents smallest grains and has better mechanical properties. Bright nickel electroplated diamond tool with slot structure and heat treatment under 200°C was suitable for optical glass drilling.
Ares I-X Ground Diagnostic Prototype
NASA Technical Reports Server (NTRS)
Schwabacher, Mark; Martin, Rodney; Waterman, Robert; Oostdyk, Rebecca; Ossenfort, John; Matthews, Bryan
2010-01-01
Automating prelaunch diagnostics for launch vehicles offers three potential benefits. First, it potentially improves safety by detecting faults that might otherwise have been missed so that they can be corrected before launch. Second, it potentially reduces launch delays by more quickly diagnosing the cause of anomalies that occur during prelaunch processing. Reducing launch delays will be critical to the success of NASA's planned future missions that require in-orbit rendezvous. Third, it potentially reduces costs by reducing both launch delays and the number of people needed to monitor the prelaunch process. NASA is currently developing the Ares I launch vehicle to bring the Orion capsule and its crew of four astronauts to low-earth orbit on their way to the moon. Ares I-X will be the first unmanned test flight of Ares I. It is scheduled to launch on October 27, 2009. The Ares I-X Ground Diagnostic Prototype is a prototype ground diagnostic system that will provide anomaly detection, fault detection, fault isolation, and diagnostics for the Ares I-X first-stage thrust vector control (TVC) and for the associated ground hydraulics while it is in the Vehicle Assembly Building (VAB) at John F. Kennedy Space Center (KSC) and on the launch pad. It will serve as a prototype for a future operational ground diagnostic system for Ares I. The prototype combines three existing diagnostic tools. The first tool, TEAMS (Testability Engineering and Maintenance System), is a model-based tool that is commercially produced by Qualtech Systems, Inc. It uses a qualitative model of failure propagation to perform fault isolation and diagnostics. We adapted an existing TEAMS model of the TVC to use for diagnostics and developed a TEAMS model of the ground hydraulics. The second tool, Spacecraft Health Inference Engine (SHINE), is a rule-based expert system developed at the NASA Jet Propulsion Laboratory. We developed SHINE rules for fault detection and mode identification. The prototype uses the outputs of SHINE as inputs to TEAMS. The third tool, the Inductive Monitoring System (IMS), is an anomaly detection tool developed at NASA Ames Research Center and is currently used to monitor the International Space Station Control Moment Gyroscopes. IMS automatically "learns" a model of historical nominal data in the form of a set of clusters and signals an alarm when new data fails to match this model. IMS offers the potential to detect faults that have not been modeled. The three tools have been integrated and deployed to Hangar AE at KSC where they interface with live data from the Ares I-X vehicle and from the ground hydraulics. The outputs of the tools are displayed on a console in Hangar AE, one of the locations from which the Ares I-X launch will be monitored. The full paper will describe how the prototype performed before the launch. It will include an analysis of the prototype's accuracy, including false-positive rates, false-negative rates, and receiver operating characteristics (ROC) curves. It will also include a description of the prototype's computational requirements, including CPU usage, main memory usage, and disk usage. If the prototype detects any faults during the prelaunch period then the paper will include a description of those faults. Similarly, if the prototype has any false alarms then the paper will describe them and will attempt to explain their causes.
NASA Astrophysics Data System (ADS)
Martínez-Paredes, M.; Bruzual, G.; Meléndez, M.; González-Martín, O.
2017-11-01
The optical diagnostic diagram te{BPT81, VO87} allow us to discriminate between the different excitation mechanism, like that produce by young stars and that produce by the AGN during the accretion of matter onto the super massive black hole. This kind of tool are important because allow us to study the connection between starburst and AGN. However, despite the great success, the identification of the most heavily dust-obscured systems remains a challenge for optical diagrams. Mid-infrared diagnostic are more suitable to study dust-enshrouded systems, where the effect of dust obscuration can hamper the interpretation of traditional optical diagnostics, since in this spectral range we have access to low-ionization lines (as [Ne II]12.8μm) typical of star forming regions and high ionization lines typical of active galaxies ([OIV]25.9μm), while intermediate ionization-lines ([Ne III]15.3μm) provide a unique scenario where the AGN coexist with active star formation in the host galaxy. In a previous work te{Melendez14} we have carried out extensive and detailed photoionization modeling to successfully separate the different excitation mechanism in the mid-infrared diagnostic diagrams proposed by te{Weaver10}. We successfully modelled the AGN and starburst galaxies ratios lines of [NeIII]/[NeII] Vs [OIV]/[NeIII]. However, we failed in modelling the observed ratio lines in galaxies with a normal star formation activity ([NeIII]/[NeII]<1 and [OIV]/[NeIII]<1). These results suggest the presence of a more complex excitation mechanism in these galaxies. In this project we are using the update stellar population models from te{BC17} that include massive stars, and the update photoionization models from CLOUDY from te{Ferland17}, to characterize the properties of the stellar population that produce the high ionization conditions in these galaxies.
NASA Technical Reports Server (NTRS)
2001-01-01
Qualtech Systems, Inc. developed a complete software system with capabilities of multisignal modeling, diagnostic analysis, run-time diagnostic operations, and intelligent interactive reasoners. Commercially available as the TEAMS (Testability Engineering and Maintenance System) tool set, the software can be used to reveal unanticipated system failures. The TEAMS software package is broken down into four companion tools: TEAMS-RT, TEAMATE, TEAMS-KB, and TEAMS-RDS. TEAMS-RT identifies good, bad, and suspect components in the system in real-time. It reports system health results from onboard tests, and detects and isolates failures within the system, allowing for rapid fault isolation. TEAMATE takes over from where TEAMS-RT left off by intelligently guiding the maintenance technician through the troubleshooting procedure, repair actions, and operational checkout. TEAMS-KB serves as a model management and collection tool. TEAMS-RDS (TEAMS-Remote Diagnostic Server) has the ability to continuously assess a system and isolate any failure in that system or its components, in real time. RDS incorporates TEAMS-RT, TEAMATE, and TEAMS-KB in a large-scale server architecture capable of providing advanced diagnostic and maintenance functions over a network, such as the Internet, with a web browser user interface.
Imaging of congenital heart disease in adults: choice of modalities.
Orwat, Stefan; Diller, Gerhard-Paul; Baumgartner, Helmut
2014-01-01
Major advances in noninvasive imaging of adult congenital heart disease have been accomplished. These tools play now a key role in comprehensive diagnostic work-up, decision for intervention, evaluation for the suitability of specific therapeutic options, monitoring of interventions and regular follow-up. Besides echocardiography, magnetic resonance (CMR) and computed tomography (CT) have gained particular importance. The choice of imaging modality has thus become a critical issue. This review summarizes strengths and limitations of the different imaging modalities and how they may be used in a complementary fashion. Echocardiography obviously remains the workhorse of imaging routinely used in all patients. However, in complex disease and after surgery echocardiography alone frequently remains insufficient. CMR is particularly useful in this setting and allows reproducible and accurate quantification of ventricular function and comprehensive assessment of cardiac anatomy, aorta, pulmonary arteries and venous return including complex flow measurements. CT is preferred when CMR is contraindicated, when superior spatial resolution is required or when "metallic" artefacts limit CMR imaging. In conclusion, the use of currently available imaging modalities in adult congenital heart disease needs to be complementary. Echocardiography remains the basis tool, CMR and CT should be added considering specific open questions and the ability to answer them, availability and economic issues.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, R.Y.; Troncoso, P.; El-Naggar, A.K.
1994-09-01
Identification of chromosomal aberrations that may be used for diagnostic or prognostic evaluation of prostatic adenocarcinoma has been the subject of great interest. In a previous study, we applied the fluorescence in situ hybridization (FISH) method on paraffin-embedded material to show that trisomy 7 was associated with the progression of human prostate cancer. In this study, we attempted to assess the utility of the FISH technique in detecting aneuploidy in fine needle aspirate (FNA) smears of prostatic tissues and to compare FISH results with that of DNA flow cytometry (FCM). Paired samples of normal and tumor FNA smears were obtainedmore » from 10 radical prostatectomy specimens. Dual-color chromosomes 7 and 9-specific centromeric DNA probes were used for FISH. FISH analysis demonstrated increased frequencies of trisomy 7 cells in all 10 tumors studied when compared with the paired normals. In contrast, 6 of 10 tumors were determined to be diploid by FCM. Our results show that FNA of radical prostatectomy specimens is a practical method for obtaining suitable material for both FISH and FCM analyses of prostate carcinoma. Thus, interphase FISH may be a practical screening tool to determine aneuploidy in FNA smears of prostatic carcinoma.« less
Reducing waste in evaluation studies on fall risk assessment tools for older people.
Meyer, Gabriele; Möhler, Ralph; Köpke, Sascha
2018-05-18
To critically appraise the recognition of methodological challenges in evaluation studies on assessment tools and nurses' clinical judgement on fall risk in older people and suggest how to reduce respective research waste. Opinion paper and narrative review covering systematic reviews on studies assessing diagnostic accuracy and impact of assessment tools and/or nurses' clinical judgement. Eighteen reviews published in the last 15 years were analysed. Only one reflects potentially important factors threatening the accuracy of assessments using delayed verification with fall events as reference after a certain period of time, i.e. natural course, preventive measures and treatment paradox where accurate assessment leads to prevention of falls, i.e. influencing the reference standard and falsely indicating low diagnostic accuracy. Also, only one review mentions randomised controlled trials as appropriate study design for the investigation of the impact of fall risk assessment tools on patient-important outcomes. Until now, only one randomised controlled trial dealing with this question has been performed showing no effect on falls and injuries. Instead of investigating the diagnostic accuracy of fall assessment tools, the focus of future research should be on the effectiveness of the implementation of fall assessment tools at reducing falls and injuries. Copyright © 2018. Published by Elsevier Inc.
Iridology: A systematic review.
Ernst, E
1999-02-01
Iridologists claim to be able to diagnose medical conditions through abnormalities of pigmentation in the iris. This technique is popular in many countries. Therefore it is relevant to ask whether it is valid. To systematically review all interpretable tests of the validity of iridology as a diagnostic tool. DATA SOURCE AND EXTRACTION: Three independent literature searches were performed to identify all blinded tests. Data were extracted in a predefined, standardized fashion. Four case control studies were found. The majority of these investigations suggests that iridology is not a valid diagnostic method. The validity of iridology as a diagnostic tool is not supported by scientific evaluations. Patients and therapists should be discouraged from using this method.
Batista, W O; Navarro, M V T; Maia, A F
2013-12-01
Basically, all modalities of diagnostic radiology require phantoms suitable for dosimetric evaluations. New technologies frequently arise unaccompanied of tools for dosimetric evaluations and quality control. In this study, a low-cost phantom and a consequent proposed methodology for dosimetric evaluations in cone beam computed tomography (CBCT) were presented. The developed phantom has typical dimensions of the human face, was built in polymethyl methacrylate and filled with water. Three devices with different technological concepts were evaluated and a proposed index, kerma index-height product (PKIH), was defined as an option to the use of air kerma-area product. The results of this study show relatively uniform kerma profiles for scanners with field of views (FOVs) of large diameters and non-uniform for FOVs of small diameters. With regard to the values obtained for the kerma indexes, much higher values were found for the equipment FOVs with small diameter compared with the values of the two other equipment that have larger diameters. The results indicate that (1) there is a need for special phantoms for use in CBCT, (2) the use of P(KA) in the evaluation of protocols on different equipment can lead to false interpretations and (3) the new index is a suitable alternative for the use of P(KA) in CBCT.
Pinheiro, Leonardo B; O'Brien, Helen; Druce, Julian; Do, Hongdo; Kay, Pippa; Daniels, Marissa; You, Jingjing; Burke, Daniel; Griffiths, Kate; Emslie, Kerry R
2017-11-07
Use of droplet digital PCR technology (ddPCR) is expanding rapidly in the diversity of applications and number of users around the world. Access to relatively simple and affordable commercial ddPCR technology has attracted wide interest in use of this technology as a molecular diagnostic tool. For ddPCR to effectively transition to a molecular diagnostic setting requires processes for method validation and verification and demonstration of reproducible instrument performance. In this study, we describe the development and characterization of a DNA reference material (NMI NA008 High GC reference material) comprising a challenging methylated GC-rich DNA template under a novel 96-well microplate format. A scalable process using high precision acoustic dispensing technology was validated to produce the DNA reference material with a certified reference value expressed in amount of DNA molecules per well. An interlaboratory study, conducted using blinded NA008 High GC reference material to assess reproducibility among seven independent laboratories demonstrated less than 4.5% reproducibility relative standard deviation. With the exclusion of one laboratory, laboratories had appropriate technical competency, fully functional instrumentation, and suitable reagents to perform accurate ddPCR based DNA quantification measurements at the time of the study. The study results confirmed that NA008 High GC reference material is fit for the purpose of being used for quality control of ddPCR systems, consumables, instrumentation, and workflow.
Screening the low molecular weight fraction of human serum using ATR-IR spectroscopy.
Bonnier, Franck; Brachet, Guillaume; Duong, Romain; Sojinrin, Tobiloba; Respaud, Renaud; Aubrey, Nicolas; Baker, Matthew J; Byrne, Hugh J; Chourpa, Igor
2016-10-01
Vibrational spectroscopic techniques can detect small variations in molecular content, linked with disease, showing promise for screening and early diagnosis. Biological fluids, particularly blood serum, are potentially valuable for diagnosis purposes. The so-called Low Molecular Weight Fraction (LMWF) contains the associated peptidome and metabolome and has been identified as potentially the most relevant molecular population for disease-associated biomarker research. Although vibrational spectroscopy can deliver a specific chemical fingerprint of the samples, the High Molecular Weight Fraction (HMWF), composed of the most abundant serum proteins, strongly dominates the response and ultimately makes the detection of minor spectral variations a challenging task. Spectroscopic detection of potential serum biomarkers present at relatively low concentrations can be improved using pre-analytical depletion of the HMWF. In the present study, human serum fractionation by centrifugal filtration was used prior to analysis by Attenuated Total Reflection infrared spectroscopy. Using a model sample based on glycine spiked serum, it is demonstrated that the screening of the LMWF can be applied to quantify blinded concentrations up to 50 times lower. Moreover, the approach is easily transferable to different bodily fluids which would support the development of more efficient and suitable clinical protocols exploring vibrational spectroscopy based ex-vivo diagnostic tools. Revealing serum LMWF for spectral serological diagnostic applications. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Emmer, P M; Nelen, W L; Steegers, E A; Hendriks, J C; Veerhoek, M; Joosten, I
2000-05-01
For diagnostic purposes we assessed peripheral natural killer (NK) cell cytotoxicity and NK and T cell numbers to assess their putative predictive value in recurrent spontaneous abortion (RSA). A total of 43 women with subsequent pregnancy, 37 healthy controls and 39 women successfully partaking in an in-vitro fertilization (IVF) procedure, were included in the study. We show that before pregnancy, levels of NK cytotoxicity and numbers of both single CD56(pos) and double CD56(pos)CD16(pos) cells were similar between RSA women and controls. But notably, within the RSA group, NK cell numbers of <12% were strongly associated with a subsequent pregnancy carried to term. Supplementation of folic acid led to an increase of single CD56(pos) cells, but cytotoxic function appeared unaffected. The expression pattern of killer inhibitory receptors on CD56(pos) cells was not different between patients and controls. A longitudinal study revealed that, compared with controls, in RSA women higher numbers of double CD56(pos)CD16(pos) cells were present during early pregnancy, paralleled by an increase in cytotoxic NK cell reactivity. The single CD56(pos) population decreased in number. In conclusion, the analysis of peripheral NK cell characteristics appears a suitable diagnostic tool in RSA. Immunomodulation aimed at NK cell function appears a promising therapeutic measure.
NASA Astrophysics Data System (ADS)
Morais, A. P.; Pino, A. V.; Souza, M. N.
2016-08-01
This in vitro study evaluated the diagnostic performance of an alternative electric bioimpedance spectroscopy technique (BIS-STEP) detect questionable occlusal carious lesions. Six specialists carried out the visual (V), radiography (R), and combined (VR) exams of 57 sound or non-cavitated occlusal carious lesion teeth classifying the occlusal surfaces in sound surface (H), enamel caries (EC), and dentinal caries (DC). Measurements were based on the current response to a step voltage excitation (BIS-STEP). A fractional electrical model was used to predict the current response in the time domain and to estimate the model parameters: Rs and Rp (resistive parameters), and C and α (fractional parameters). Histological analysis showed caries prevalence of 33.3% being 15.8% hidden caries. Combined examination obtained the best traditional diagnostic results with specificity = 59.0%, sensitivity = 70.9%, and accuracy = 60.8%. There were statistically significant differences in bioimpedance parameters between the H and EC groups (p = 0.016) and between the H and DC groups (Rs, p = 0.006; Rp, p = 0.022, and α, p = 0.041). Using a suitable threshold for the Rs, we obtained specificity = 60.7%, sensitivity = 77.9%, accuracy = 73.2%, and 100% of detection for deep lesions. It can be concluded that BIS-STEP method could be an important tool to improve the detection and management of occlusal non-cavitated primary caries and pigmented sites.
Utzinger, Jürg; N'goran, Eliézer K; Caffrey, Conor R; Keiser, Jennifer
2011-09-01
Compared to malaria, tuberculosis and HIV/AIDS, schistosomiasis remains a truly neglected tropical disease. Schistosomiasis, perhaps more than any other disease, is entrenched in prevailing social-ecological systems, since transmission is governed by human behaviour (e.g. open defecation and patterns of unprotected surface water contacts) and ecological features (e.g. living in close proximity to suitable freshwater bodies in which intermediate host snails proliferate). Moreover, schistosomiasis is intimately linked with poverty and the disease has spread to previously non-endemic areas as a result of demographic, ecological and engineering transformations. Importantly though, thanks to increased advocacy there is growing awareness, financial and technical support to control and eventually eliminate schistosomiasis as a public health problem at local, regional and global scales. The purpose of this review is to highlight recent progress made in innovation, validation and application of new tools and strategies for research and integrated control of schistosomiasis. First, we explain that schistosomiasis is deeply embedded in social-ecological systems and explore linkages with poverty. We then summarize and challenge global statistics, risk maps and burden estimates of human schistosomiasis. Discovery and development research pertaining to novel diagnostics and drugs forms the centrepiece of our review. We discuss unresolved issues and emerging opportunities for integrated and sustainable control of schistosomiasis and conclude with a series of research needs. Copyright © 2010 Elsevier B.V. All rights reserved.
In vivo X-Ray excited optical luminescence from phosphor-doped aerogel and Sylgard 184 composites
NASA Astrophysics Data System (ADS)
Allison, Stephen W.; Baker, Ethan S.; Lynch, Kyle J.; Sabri, Firouzeh
2017-06-01
X-Ray excited optical luminescence (XEOL) is a new and noninvasive diagnostic technique suitable for in situ biochemical imaging and disease detection. The X-Ray excited optical luminescence of phosphor doping in crosslinked silica aerogel and Sylgard 184 hosts was investigated in this study. Composite silica aerogels and Sylgard 184 samples of 5%, 15%, and 50% concentrations by weight of La2O2S:Eu phosphor were prepared and inserted subcutaneously in a Sprague-Dawley rat and excited by X-Ray emission at 70 and 100 kV. A fiber optic bundle positioned within 5 mm of the sample collected the luminescence signal and conveyed it to a photomultiplier detector. The signal intensity scaled with dopant concentration. The time dependence of the predominantly red luminescence consisted of 60 cycle bursts of approximately 8 ms duration. The amplitude was modulated at about 10 Hz with a 60% depth. This indicates the time dependence of the X-Ray source. A simulation showed how to observe phosphor decay between individual burst pulses. The emission from the two types of composite samples was easily detected from the outside of the skin layer. Both Sylgard 184 and crosslinked silica aerogels are biocompatible and bio stable materials that could serve a variety of potential XEOL applications. These very strong signals imply potential for creating new In-vivo sensing applications and diagnostic tools.
Diagnostics of reactive oxygen species produced by microplasmas
NASA Astrophysics Data System (ADS)
Sousa, J. S.; Puech, V.
2013-11-01
Atmospheric pressure generation of reactive oxygen species (ROS) by microplasmas was experimentally studied. The remarkable stability of the microcathode sustained discharge (MCSD) allowed the operation of dc glow discharges, free from the glow-to-arc transition, in He/O2/NO mixtures at atmospheric pressure. Absolute densities of the main ROS were measured by different optical diagnostics: singlet delta oxygen (O2(a 1Δg)) by infrared emission and vacuum ultraviolet absorption in the effluent, ozone (O3) by ultraviolet absorption in the effluent, and atomic oxygen inside the discharge by two-photon absorption laser induced fluorescence. The effect of different parameters, such as gas flow and mixture, and discharge current, on the production of these ROS was studied. High ROS densities up to 1016 cm-3 were achieved. It is shown that the density ratio of O2(a 1Δg) to O3 can be finely tuned in the range [10-3-10+4], through the values of discharge current and NO concentration, and that high O2(a 1Δg) and O3 densities can be transported over distances longer than 50 cm. The MCSD is, thus, a very suitable tool for the continuous production at atmospheric pressure of large fluxes of O2(a 1Δg) and O3, useful to a wide range of applications, notably in plasma medicine.
Diagnostic tools in ocular allergy.
Leonardi, A; Doan, S; Fauquert, J L; Bozkurt, B; Allegri, P; Marmouz, F; Rondon, C; Jedrzejczak, M; Hellings, P; Delgado, L; Calder, V
2017-10-01
Ocular allergy (OA) includes a group of common and less frequent hypersensitivity disorders frequently misdiagnosed and not properly managed. The diagnosis of OA is usually based on clinical history and signs and symptoms, with the support of in vivo and in vitro tests when identification of the specific allergen is required. To date, no specific test is available for the diagnosis of the whole spectrum of the different forms of OA. The lack of recommendations on diagnosis of OA is considered a medical need not only for allergists but also for ophthalmologists. This position paper aims to provide a comprehensive overview of the currently available tools for diagnosing OA to promote a common nomenclature and procedures to be used by different specialists. Questionnaires, sign and symptom grading scales, tests, and potential biomarkers for OA are reviewed. We also identified several unmet needs in the diagnostic tools to generate interest, increase understanding, and inspire further investigations. Tools, recommendations, and algorithms for the diagnosis of OA are proposed for use by both allergists and ophthalmologists. Several unmet needs in the diagnostic tools should be further improved by specific clinical research in OA. © 2017 EAACI and John Wiley and Sons A/S. Published by John Wiley and Sons Ltd.
Canestaro, William J; Pritchard, Daryl E; Garrison, Louis P; Dubois, Robert; Veenstra, David L
2015-08-01
Companion diagnostic tests (CDTs) have emerged as a vital technology in the effective use of an increasing number of targeted drug therapies. Although CDTs can offer a multitude of potential benefits, assessing their value within a health technology appraisal process can be challenging because of a complex array of factors that influence clinical and economic outcomes. To develop a user-friendly tool to assist managed care and other health care decision makers in screening companion tests and determining whether an intensive technology review is necessary and, if so, where the review should be focused to improve efficiency. First, we conducted a systematic literature review of CDT cost-effectiveness studies to identify value drivers. Second, we conducted key informant interviews with a diverse group of stakeholders to elicit feedback and solicit any additional value drivers and identify desirable attributes for an evidence review tool. A draft tool was developed based on this information that captured value drivers, usability features, and had a particular focus on practical use by nonexperts. Finally, the tool was pilot tested with test developers and managed care evidence evaluators to assess face-validity and usability. The tool was also evaluated using several diverse examples of existing companion diagnostics and refined accordingly. We identified 65 cost-effectiveness studies of companion diagnostic technologies. The following factors were most commonly identified as value drivers from our literature review: clinical validity of testing; efficacy, safety, and cost of baseline and alternative treatments; cost and mortality of health states; and biomarker prevalence and testing cost. Stakeholders identified the following additional factors that they believed influenced the overall value of a companion test: regulatory status, actionability, utility, and market penetration. These factors were used to maximize the efficiency of the evidence review process. Stakeholders also stated that a tool should be easy to use and time efficient. Cognitive interviews with stakeholders led to minor changes in the draft tool to improve usability and relevance. The final tool consisted of 4 sections: (1) eligibility for review (2 questions), (2) prioritization of review (3 questions), (3) clinical review (3 questions), and (4) economic review (5 questions). Although the evaluation of CDTs can be challenging because of limited evidence and the added complexity of incorporating a diagnostic test into drug treatment decisions, using a pragmatic tool to identify tests that do not need extensive evaluation may improve the efficiency and effectiveness of CDT value assessments.
Synthesis and surface modification of magnetic nanoparticles for potential applications in sarcomas
NASA Astrophysics Data System (ADS)
Shahbazi, S.; Wang, X.; Yang, J.-L.; Jiang, X. C.; Ryan, R.; Yu, A. B.
2015-06-01
The application of nano-science in cancer therapy has become one of the most attractive tools in scientific research because of its versatility in diagnosis and treatment. Among the different types of nanoparticles, iron oxide nanoparticles (IONPs) are renowned for their low toxicity and suitability for therapeutic and diagnostic, or `theragnostic,' approach against different types of cancers. Research investigating the effect of IONPs with different physiochemical characteristics in sarcoma is limited. In this study, we initially prepared IONPs of different sizes (200, 100, 20, and 10 nm) and modified their surface with different types of coatings (polyethylene glycol, d-glucose, and silica) under mild conditions. Various methods were used to illustrate and quantify cellular uptake of magnetic nanoparticles in sarcoma cell lines. Finally, the safety of the uptaken nanoparticles on diverse human sarcoma cell lines was investigated and found that the readily available IONPs can be taken up by synovial sarcoma and liposarcoma cell lines in the selective histological tumor types; however, they seem highly toxic for fibrous histiocytoma and fibrosarcoma.
Flow Cytometric Methods for Circulating Tumor Cell Isolation and Molecular Analysis.
Bhagwat, Neha; Carpenter, Erica L
2017-01-01
Circulating tumor cells provide a non-invasive source of tumor material that can be valuable at all stages of disease management, including screening and early diagnosis, monitoring response to therapy, identifying therapeutic targets, and assessing development of drug resistance. Cells isolated from the blood of cancer patients can be used for phenotypic analysis, tumor genotyping, transcriptional profiling, as well as for ex vivo culture of isolated cells. There are a variety of novel technologies currently being developed for the detection and analysis of rare cells in circulation of cancer patients. Flow cytometry is a powerful cell analysis platform that is increasingly being used in this field of study due to its relatively high throughput and versatility with respect to the large number of commercially available antibodies and fluorescent probes available to translational and clinical researchers. More importantly, it offers the ability to easily recover viable cells with high purity that are suitable for downstream molecular analysis, thus making it an attractive technology for cancer research and as a diagnostic tool.
Advanced yellow fever virus genome detection in point-of-care facilities and reference laboratories.
Domingo, Cristina; Patel, Pranav; Yillah, Jasmin; Weidmann, Manfred; Méndez, Jairo A; Nakouné, Emmanuel Rivalyn; Niedrig, Matthias
2012-12-01
Reported methods for the detection of the yellow fever viral genome are beset by limitations in sensitivity, specificity, strain detection spectra, and suitability to laboratories with simple infrastructure in areas of endemicity. We describe the development of two different approaches affording sensitive and specific detection of the yellow fever genome: a real-time reverse transcription-quantitative PCR (RT-qPCR) and an isothermal protocol employing the same primer-probe set but based on helicase-dependent amplification technology (RT-tHDA). Both assays were evaluated using yellow fever cell culture supernatants as well as spiked and clinical samples. We demonstrate reliable detection by both assays of different strains of yellow fever virus with improved sensitivity and specificity. The RT-qPCR assay is a powerful tool for reference or diagnostic laboratories with real-time PCR capability, while the isothermal RT-tHDA assay represents a useful alternative to earlier amplification techniques for the molecular diagnosis of yellow fever by field or point-of-care laboratories.
Zhou, Zijian; Wu, Changqiang; Liu, Hanyu; Zhu, Xianglong; Zhao, Zhenghuan; Wang, Lirong; Xu, Ye; Ai, Hua; Gao, Jinhao
2015-03-24
Magnetic resonance angiography using gadolinium-based molecular contrast agents suffers from short diagnostic window, relatively low resolution and risk of toxicity. Taking into account the chemical exchange between metal centers and surrounding protons, magnetic nanoparticles with suitable surface and interfacial features may serve as alternative T1 contrast agents. Herein, we report the engineering on surface structure of iron oxide nanoplates to boost T1 contrast ability through synergistic effects between exposed metal-rich Fe3O4(100) facets and embedded Gd2O3 clusters. The nanoplates show prominent T1 contrast in a wide range of magnetic fields with an ultrahigh r1 value up to 61.5 mM(-1) s(-1). Moreover, engineering on nanobio interface through zwitterionic molecules adjusts the in vivo behaviors of nanoplates for highly efficient magnetic resonance angiography with steady-state acquisition window, superhigh resolution in vascular details, and low toxicity. This study provides a powerful tool for sophisticated design of MRI contrast agents for diverse use in bioimaging applications.
Koishi, Andrea Cristine; Aoki, Mateus Nóbrega; Jorge, Taissa Ricciardi; Suzukawa, Andréia Akemi; Zanluca, Camila; Levis, Silvana; Duarte Dos Santos, Claudia Nunes
2016-07-01
Hantaviruses are etiologic agents of a zoonotic disease transmitted mainly from wild rodents to humans, causing Hemorrhagic Fever with Renal Syndrome in Eurasia and the Hantavirus Cardiopulmonary Syndrome in the Americas (HCPS), reaching a lethality rate of 40% in Brazil. Hantavirus diagnostic and seroprevalence are often based on the presence of IgM and IgG antibodies against the virus. Here we propose a rapid test assay able to identify hantavirus antibodies with sensibility and specificity similar to ELISA assays. We analyzed five groups of samples, including healthy human population and small mammals of endemic areas, suspected cases of HCPS, patients with non-related infections and a serum panel from a different geographical region. The test presented good rates of sensibility (87-100%) and specificity (97-100%) for all groups, being a promising tool suitable for both rodent and human hantavirus epidemiological surveys. Copyright © 2016 Elsevier Inc. All rights reserved.
Toward a low-cost gait analysis system for clinical and free-living assessment.
Ladha, Cassim; Del Din, Silvia; Nazarpour, Kianoush; Hickey, Aodhan; Morris, Rosie; Catt, Michael; Rochester, Lynn; Godfrey, Alan
2016-08-01
Gait is an important clinical assessment tool since changes in gait may reflect changes in general health. Measurement of gait is a complex process which has been restricted to bespoke clinical facilities until recently. The use of inexpensive wearable technologies is an attractive alternative and offers the potential to assess gait in any environment. In this paper we present the development of a low cost analysis gait system built using entirely open source components. The system is used to capture spatio-temporal gait characteristics derived from an existing conceptual model, sensitive to ageing and neurodegenerative pathology (e.g. Parkinson's disease). We demonstrate the system is suitable for use in a clinical unit and will lead to pragmatic use in a free-living (home) environment. The system consists of a wearable (tri-axial accelerometer and gyroscope) with a Raspberry Pi module for data storage and analysis. This forms ongoing work to develop gait as a low cost diagnostic in modern healthcare.
Proteomic approaches in brain research and neuropharmacology.
Vercauteren, Freya G G; Bergeron, John J M; Vandesande, Frans; Arckens, Lut; Quirion, Rémi
2004-10-01
Numerous applications of genomic technologies have enabled the assembly of unprecedented inventories of genes, expressed in cells under specific physiological and pathophysiological conditions. Complementing the valuable information generated through functional genomics with the integrative knowledge of protein expression and function should enable the development of more efficient diagnostic tools and therapeutic agents. Proteomic analyses are particularly suitable to elucidate posttranslational modifications, expression levels and protein-protein interactions of thousands of proteins at a time. In this review, two-dimensional polyacrylamide gel electrophoresis (2D-PAGE) investigations of brain tissues in neurodegenerative diseases such as Alzheimer's disease, Down syndrome and schizophrenia, and the construction of 2D-PAGE proteome maps of the brain are discussed. The role of the Human Proteome Organization (HUPO) as an international coordinating organization for proteomic efforts, as well as challenges for proteomic technologies and data analysis are also addressed. It is expected that the use of proteomic strategies will have significant impact in neuropharmacology over the coming decade.
Lee, D W; Byeon, H K; Chung, H P; Choi, E C; Kim, S-H; Park, Y M
2013-07-01
The findings of intraparotid facial nerve schwannoma (FNS) using preoperative diagnostic tools, including ultrasonography (US)-guided fine needle aspiration biopsy, computed tomography (CT) scan, and magnetic resonance imaging (MRI), were analyzed to determine if there are any useful findings that might suggest the presence of a lesion. Treatment guidelines are suggested. The medical records of 15 patients who were diagnosed with an intraparotid FNS were retrospectively analyzed. US and CT scans provide clinicians with only limited information; gadolinium enhanced T1-weighted images from MRI provide more specific findings. Tumors could be removed successfully with surgical exploration, preserving facial nerve function at the same time. Gadolinium-enhanced T1-weighted MRI showed more characteristic findings for the diagnosis of intraparotid FNS. Intraparotid FNS without facial palsy can be diagnosed with MRI preoperatively, and surgical exploration is a suitable treatment modality which can remove the tumor and preserve facial nerve function. Crown Copyright © 2013. Published by Elsevier Ltd. All rights reserved.
In Situ Optical Mapping of Voltage and Calcium in the Heart
Ewart, Paul; Ashley, Euan A.; Loew, Leslie M.; Kohl, Peter; Bollensdorff, Christian; Woods, Christopher E.
2012-01-01
Electroanatomic mapping the interrelation of intracardiac electrical activation with anatomic locations has become an important tool for clinical assessment of complex arrhythmias. Optical mapping of cardiac electrophysiology combines high spatiotemporal resolution of anatomy and physiological function with fast and simultaneous data acquisition. If applied to the clinical setting, this could improve both diagnostic potential and therapeutic efficacy of clinical arrhythmia interventions. The aim of this study was to explore this utility in vivo using a rat model. To this aim, we present a single-camera imaging and multiple light-emitting-diode illumination system that reduces economic and technical implementation hurdles to cardiac optical mapping. Combined with a red-shifted calcium dye and a new near-infrared voltage-sensitive dye, both suitable for use in blood-perfused tissue, we demonstrate the feasibility of in vivo multi-parametric imaging of the mammalian heart. Our approach combines recording of electrophysiologically-relevant parameters with observation of structural substrates and is adaptable, in principle, to trans-catheter percutaneous approaches. PMID:22876327
Cross-sectional imaging of extracted jawbone of a pig by optical coherence tomography
NASA Astrophysics Data System (ADS)
Tachikawa, Noriko; Yoshimura, Reiko; Ohbayashi, Kohji
2011-03-01
Dental implantation has become popular in dental treatments. Although careful planning is made to identify vital structures such as the inferior alveolar nerve or the sinus, as well as dimensions of the bone, prior to commencement of surgery, dental implantation is not fully free from risks. If a diagnostic tool is available to objectively measure bone feature before surgery and dimensions during surgery, considerable fraction of the risks may be avoided. Optical coherence tomography (OCT) is a candidate for the purpose, which enables cross-sectional imaging of bone. In this work, we performed in vitro cross-sectional imaging of extracted pig's jawbone with swept source OCT using superstructure-grating distributed Bragg reflector (SSG-DBR) laser as the source. The relatively long wavelength range of 1600nm of the laser is suitable for deeper bone imaging. We confirmed an image penetration depth of about 3 mm in physical length, which satisfies one of the criterions to apply OCT for in vivo diagnosis of bone during surgery.
[Current aspects of the definition and diagnosis of sepsis and antibiotic resistance].
Brunkhorst, Frank M; Gastmeier, Petra; Abu Sin, Muna
2018-05-01
Hospital mortality of patients with secondary sepsis remains high at around 40%. Because of the methodological deficiencies of the definitions used so far, valid epidemiological data on secondary sepsis that allow for national and international comparisons are lacking. Since 2016, new clinical diagnostic tools that are also suitable for sepsis screening outside of intensive care units have been available. To counteract the high mortality of nosocomial sepsis, new approaches to the early identification of at-risk patients are needed. An adequate blood culture sampling rate and a high preanalytical quality should be established as a basis for quality assurance, especially in the field of nosocomial bloodstream infections; otherwise, there is a risk of surveillance bias. Data from laboratory-based antibiotic resistance surveillance on MRSA in blood culture isolates have shown a downward trend over the last 4 years. In Gram-negative pathogens, a relatively stable resistance situation has been observed over this period for many of the pathogen-antibiotic combinations.
Does the sympathetic nervous system contribute to the pathophysiology of metabolic syndrome?
Moreira, Marina C. dos Santos; Pinto, Izabella S. de Jesus; Mourão, Aline A.; Fajemiroye, James O.; Colombari, Eduardo; Reis, Ângela A. da Silva; Freiria-Oliveira, André H.; Ferreira-Neto, Marcos L.; Pedrino, Gustavo R.
2015-01-01
The metabolic syndrome (MS), formally known as syndrome X, is a clustering of several risk factors such as obesity, hypertension, insulin resistance, and dislypidemia which could lead to the development of diabetes and cardiovascular diseases (CVD). The frequent changes in the definition and diagnostic criteria of MS are indications of the controversy and the challenges surrounding the understanding of this syndrome among researchers. Obesity and insulin resistance are leading risk factors of MS. Moreover, obesity and hypertension are closely associated to the increase and aggravation of oxidative stress. The recommended treatment of MS frequently involves change of lifestyles to prevent weight gain. MS is not only an important screening tool for the identification of individuals at high risk of CVD and diabetes but also an indicator of suitable treatment. As sympathetic disturbances and oxidative stress are often associated with obesity and hypertension, the present review summarizes the role of sympathetic nervous system and oxidative stress in the MS. PMID:26379553
Modified carbon nanotubes: from nanomedicine to nanotoxicology
NASA Astrophysics Data System (ADS)
Bottini, Massimo; Bottini, Nunzio
2012-09-01
Nanomedicine is the science of fabricating smart devices able to diagnose and treat diseases more efficiently than conventional medicine while minimizing costs, complexity and adverse effects. Carbon nanotubes (CNTs) are receiving considerable attention for biomedical applications due to their extraordinary properties. In particular, their chemical nature and high aspect ratio (ratio between the length and the diameter) make them ideal carriers to achieve delivery of high doses of therapeutic and imaging cargo to a specific site of interest. A major obstacle to the use of pristine (unmodified) CNTs in biological systems is their complete aqueous insolubility and low biocompatibility and toxicity profiles. To endow CNTs with solubility in a biological milieu, several non-covalent and covalent modification methods have been explored. Suitably modified CNTs have shown increased solubility under physiological conditions, improved biocompatibility profiles and lack of toxicity after injection in living animals. Additionally, after being loaded with cargo (small molecules, proteins, peptides or nucleic acids) they have been successfully evaluated as pharmaceutical, therapeutic and diagnostic tools.
Grasso, Giuseppe; Calcagno, Marzia; Rapisarda, Alessandro; D'Agata, Roberta; Spoto, Giuseppe
2017-06-01
The analytical methods that are usually applied to determine the compositions of inks from ancient manuscripts usually focus on inorganic components, as in the case of iron gall ink. In this work, we describe the use of atmospheric pressure/matrix-assisted laser desorption ionization-mass spectrometry (AP/MALDI-MS) as a spatially resolved analytical technique for the study of the organic carbonaceous components of inks used in handwritten parts of ancient books for the first time. Large polycyclic aromatic hydrocarbons (L-PAH) were identified in situ in the ink of XVII century handwritten documents. We prove that it is possible to apply MALDI-MS as a suitable microdestructive diagnostic tool for analyzing samples in air at atmospheric pressure, thus simplifying investigations of the organic components of artistic and archaeological objects. The interpretation of the experimental MS results was supported by independent Raman spectroscopic investigations. Graphical abstract Atmospheric pressure/MALDI mass spectrometry detects in situ polycyclic aromatic hydrocarbons in the carbonaceous ink of XVII century manuscripts.
Polymerase chain reaction: A molecular diagnostic tool in periodontology
Maheaswari, Rajendran; Kshirsagar, Jaishree Tukaram; Lavanya, Nallasivam
2016-01-01
This review discusses the principles of polymerase chain reaction (PCR) and its application as a diagnostic tool in periodontology. The relevant MEDLINE and PubMed indexed journals were searched manually and electronically by typing PCR, applications of PCR, PCR in periodontics, polymorphism studies in periodontitis, and molecular techniques in periodontology. The searches were limited to articles in English language and the articles describing PCR process and its relation to periodontology were collected and used to prepare a concise review. PCR has now become a standard diagnostic and research tool in periodontology. Various studies reveal that its sensitivity and specificity allow it as a rapid, efficient method of detecting, identifying, and quantifying organism. Different immune and inflammatory markers can be identified at the mRNA expression level, and also the determination of genetic polymorphisms, thus providing the deeper insight into the mechanisms underlying the periodontal disease. PMID:27143822
Brendefur, Jonathan L; Johnson, Evelyn S; Thiede, Keith W; Strother, Sam; Severson, Herb H
2018-01-01
There is a critical need to identify primary level students experiencing difficulties in mathematics to provide immediate and targeted instruction that remediates their deficits. However, most early math screening instruments focus only on the concept of number, resulting in inadequate and incomplete information for teachers to design intervention efforts. We propose a mathematics assessment that screens and provides diagnostic information in six domains that are important to building a strong foundation in mathematics. This article describes the conceptual framework and psychometric qualities of a web-based assessment tool, the Primary Math Assessment (PMA). The PMA includes a screener to identify students at risk for poor math outcomes and a diagnostic tool to provide a more in-depth profile of children's specific strengths and weaknesses in mathematics. The PMA allows teachers and school personnel to make better instructional decisions by providing more targeted analyses.
Miyashita, Yoshihiro; Hirotsu, Yosuke; Tsutsui, Toshiharu; Higashi, Seishi; Sogami, Yusuke; Kakizaki, Yumiko; Goto, Taichiro; Amemiya, Kenji; Oyama, Toshio; Omata, Masao
2017-01-01
Bronchoendoscopic examination is not necessarily comfortable procedure and limited by its sensitivity, depending on the location and size of the tumor lesion. Patients with a non-diagnostic bronchoendoscopic examination often undergo further invasive examinations. Non-invasive diagnostic tool of lung cancer is desired. A 72-year-old man had a 3.0 cm × 2.5 cm mass lesion in the segment B1 of right lung. Cytological examination of sputum, bronchial washing and curetted samples were all "negative". We could confirm a diagnosis of lung cancer after right upper lung lobe resection pathologically, and also obtained concordant results by genomic analysis using cytological negative samples from airways collected before operation. Genetic analysis showed mutational profiles of both resected specimens and samples from airways were identical. These data clearly indicated the next generation sequencing (NGS) may yield a diagnostic tool to conduct "precision medicine".
Podocytes from the diagnostic and therapeutic point of view.
Müller-Deile, Janina; Schiffer, Mario
2017-08-01
The central role of podocytes in glomerular diseases makes this cell type an interesting diagnostic tool as well as a therapeutic target. In this review, we discuss the current literature on the use of podocytes and podocyte-specific markers as non-invasive diagnostic tools in different glomerulopathies. Furthermore, we highlight the direct effects of drugs currently used to treat primary glomerular diseases and describe their direct cellular effects on podocytes. A new therapeutic potential is seen in drugs targeting the podocytic actin cytoskeleton which is essential for podocyte foot process structure and function. Incubation of cultured human podocyte cell lines with sera from patients with active glomerular diseases is currently also used to identify novel circulating factors with pathophysiological relevance for the glomerular filtration barrier. In addition, treatment of detached urinary podocytes from patients with substances that restore their cytoskeleton might serve as a novel personalized tool to estimate their potential for podocyte recovery ex vivo.
Ultrasound as Diagnostic Tool for Diaphragmatic Myoclonus
Llaneza Ramos, Vesper Fe Marie; Considine, Elaine; Karp, Barbara I.; Lungu, Codrin; Alter, Katharine; Hallett, Mark
2015-01-01
Background Diaphragmatic myoclonus is a rare disorder of repetitive diaphragmatic contractions, acknowledged to be a spectrum that includes psychogenic features. Electromyography has been the diagnostic tool most commonly used in the literature. Methods To test if we could perform a noninvasive technique to delineate the diaphragm as the source of abnormal movements and demonstrate distractibility and entrainability, we used B-mode ultrasound in a patient with diaphragmatic myoclonus. Results Ultrasound imaging clearly delineated the diaphragm as the source of her abdominal movements. We were able to demonstrate entrainability of the diaphragm to hand tapping to a prescribed rhythm set by examiner. Conclusion We recommend the use of ultrasound as a noninvasive, convenient diagnostic tool for further studies of diaphragmatic myoclonus. We agree with previous findings that diaphragmatic myoclonus may be a functional movement disorder, as evidenced by distractibility and entrainability demonstrated on real-time video with ultrasonography. PMID:27430001
Polymerase chain reaction: A molecular diagnostic tool in periodontology.
Maheaswari, Rajendran; Kshirsagar, Jaishree Tukaram; Lavanya, Nallasivam
2016-01-01
This review discusses the principles of polymerase chain reaction (PCR) and its application as a diagnostic tool in periodontology. The relevant MEDLINE and PubMed indexed journals were searched manually and electronically by typing PCR, applications of PCR, PCR in periodontics, polymorphism studies in periodontitis, and molecular techniques in periodontology. The searches were limited to articles in English language and the articles describing PCR process and its relation to periodontology were collected and used to prepare a concise review. PCR has now become a standard diagnostic and research tool in periodontology. Various studies reveal that its sensitivity and specificity allow it as a rapid, efficient method of detecting, identifying, and quantifying organism. Different immune and inflammatory markers can be identified at the mRNA expression level, and also the determination of genetic polymorphisms, thus providing the deeper insight into the mechanisms underlying the periodontal disease.
2013-01-01
Background Human leukocyte antigen matching at allelic resolution is proven clinically significant in hematopoietic stem cell transplantation, lowering the risk of graft-versus-host disease and mortality. However, due to the ever growing HLA allele database, tissue typing laboratories face substantial challenges. In light of the complexity and the high degree of allelic diversity, it has become increasingly difficult to define the classical transplantation antigens at high-resolution by using well-tried methods. Thus, next-generation sequencing is entering into diagnostic laboratories at the perfect time and serving as a promising tool to overcome intrinsic HLA typing problems. Therefore, we have developed and validated a scalable automated HLA class I and class II typing approach suitable for diagnostic use. Results A validation panel of 173 clinical and proficiency testing samples was analysed, demonstrating 100% concordance to the reference method. From a total of 1,273 loci we were able to generate 1,241 (97.3%) initial successful typings. The mean ambiguity reduction for the analysed loci was 93.5%. Allele assignment including intronic sequences showed an improved resolution (99.2%) of non-expressed HLA alleles. Conclusion We provide a powerful HLA typing protocol offering a short turnaround time of only two days, a fully integrated workflow and most importantly a high degree of typing reliability. The presented automated assay is flexible and can be scaled by specific primer compilations and the use of different 454 sequencing systems. The workflow was successfully validated according to the policies of the European Federation for Immunogenetics. Next-generation sequencing seems to become one of the new methods in the field of Histocompatibility. PMID:23557197
Shadfan, Basil H.; Simmons, Archana R.; Simmons, Glennon W.; Ho, Andy; Wong, Jorge; Lu, Karen H.; Bast, Robert C.; McDevitt, John T.
2015-01-01
Point-of-care (POC) diagnostic platforms have the potential to enable low-cost, large-scale screening. As no single biomarker is shed by all ovarian cancers, multiplexed biomarker panels promise improved sensitivity and specificity to address the unmet need for early detection of ovarian cancer. We have configured the programmable bio-nano-chip (p-BNC) - a multiplexable, microfluidic, modular platform - to quantify a novel multimarker panel comprising CA125, HE4, MMP-7 and CA72-4. The p-BNC is a bead-based immunoanalyzer system with a credit-card-sized footprint that integrates automated sample metering, bubble and debris removal, reagent storage and waste disposal, permitting POC analysis. Multiplexed p-BNC immunoassays demonstrated high specificity, low cross-reactivity, low limits of detection suitable for early detection, and a short analysis time of 43 minutes. Day-to-day variability, a critical factor for longitudinally monitoring biomarkers, ranged between 5.4–10.5%, well below the biological variation for all four markers. Biomarker concentrations for 31 late-stage sera correlated well (R2 = 0.71 to 0.93 for various biomarkers) with values obtained on the Luminex® platform. In a 31 patient cohort encompassing early- and late-stage ovarian cancers along with benign and healthy controls, the multiplexed p-BNC panel was able to distinguish cases from controls with 68.7% sensitivity at 80% specificity. Utility for longitudinal biomarker monitoring was demonstrated with pre-diagnostic sera from 2 cases and 4 controls. Taken together, the p-BNC shows strong promise as a diagnostic tool for large-scale screening that takes advantage of faster results and lower costs while leveraging possible improvement in sensitivity and specificity from biomarker panels. PMID:25388014
Corbett, E. L.; MacPherson, P.
2014-01-01
SUMMARY Twenty years of sky-high tuberculosis (TB) incidence rates and high TB mortality in high human immunodeficiency virus (HIV) prevalence countries have so far not been matched by the same magnitude or breadth of responses as seen in malaria or HIV programmes. Instead, recommendations have been narrowly focused on people presenting to health facilities for investigation of TB symptoms, or for HIV testing and care. However, despite the recent major investment and scale-up of TB and HIV services, undiagnosed TB remains highly prevalent at community level, implying that diagnosis of TB remains slow and incomplete. This maintains high transmission rates and exposes people living with HIV to high rates of morbidity and mortality. More intensive use of TB screening, with broader definitions of target populations, expanded indications for screening both inside and outside of health facilities, and appropriate selection of new diagnostic tools, offers the prospect of rapidly improving population-level control of TB. Diagnostic accuracy of suitable (high throughput) algorithms remains the major barrier to realising this goal. In the present study, we review the evidence available to guide expanded TB screening in HIV-prevalent settings, ideally through combined TB-HIV interventions that provide screening for both TB and HIV, and maximise entry to HIV and TB care and prevention. Ideally, we would systematically test, treat and prevent TB and HIV comprehensively, offering both TB and HIV screening to all health facility attendees, TB households and all adults in the highest risk communities. However, we are still held back by inadequate diagnostics, financing and paucity of population-impact data. Relevant contemporary research showing the high need for potential gains, and pitfalls from expanded and intensified TB screening in high HIV prevalence settings are discussed in this review. PMID:23928165
Low-technology cooling box for storage of malaria RDTs and other medical supplies in remote areas.
Chanthap, Lon; Ariey, Frédéric; Socheat, Duong; Tsuyuoka, Reiko; Bell, David
2010-01-23
With the increase in use of point-of-care diagnostic tests for malaria and other diseases comes the necessity of storing the diagnostic kits and the drugs required for subsequent management, in remote areas, where temperatures are high and electricity supply is unreliable or unavailable. To address the lack of temperature-controlled storage during the introduction of community-based malaria management in Cambodia, the Cambodian National Centre for Parasitology, Entomology and Malaria Control (CNM) developed prototype evaporative cooling boxes (Cambodian Cooler Boxes - CCBs) for storage of perishable medical commodities in remote clinics. The performance of these CCBs for maintaining suitable storage temperatures was evaluated over two phases in 2005 and 2006-7, comparing conditions in CCBs using water as designed, CCBs with no water for evaporation, and ambient storage room temperatures. Temperature and humidity was monitored, together with the capacity of the RDTs recommended for storage between 2 to 30 degree Celsius to detect low-density malaria parasite samples after storage under these conditions. Significant differences were recorded between the proportion of temperatures within the recommended RDT storage conditions in the CCBs with water and the temperatures in the storage room (p < 0.001) and maximum temperatures were lower. RDTs stored at ambient temperatures were negative when tested with parasitized blood (2,000 parasites per micro litre) at 210 days, while the field RDTs kept in CCBs with water gave positive results until 360 days. The CCB was an effective tool for storage of RDTs at optimal conditions, and extended the effective life-span of the tests. The concept of evaporative cooling has potential to greatly enhance access to perishable diagnostics and medicines in remote communities, as it allows prolonged storage at low cost using locally-available materials, in the absence of electricity.
Osmundson, Todd W; Eyre, Catherine A; Hayden, Katherine M; Dhillon, Jaskirn; Garbelotto, Matteo M
2013-01-01
The ubiquity, high diversity and often-cryptic manifestations of fungi and oomycetes frequently necessitate molecular tools for detecting and identifying them in the environment. In applications including DNA barcoding, pathogen detection from plant samples, and genotyping for population genetics and epidemiology, rapid and dependable DNA extraction methods scalable from one to hundreds of samples are desirable. We evaluated several rapid extraction methods (NaOH, Rapid one-step extraction (ROSE), Chelex 100, proteinase K) for their ability to obtain DNA of quantity and quality suitable for the following applications: PCR amplification of the multicopy barcoding locus ITS1/5.8S/ITS2 from various fungal cultures and sporocarps; single-copy microsatellite amplification from cultures of the phytopathogenic oomycete Phytophthora ramorum; probe-based P. ramorum detection from leaves. Several methods were effective for most of the applications, with NaOH extraction favored in terms of success rate, cost, speed and simplicity. Frozen dilutions of ROSE and NaOH extracts maintained PCR viability for over 32 months. DNA from rapid extractions performed poorly compared to CTAB/phenol-chloroform extracts for TaqMan diagnostics from tanoak leaves, suggesting that incomplete removal of PCR inhibitors is an issue for sensitive diagnostic procedures, especially from plants with recalcitrant leaf chemistry. NaOH extracts exhibited lower yield and size than CTAB/phenol-chloroform extracts; however, NaOH extraction facilitated obtaining clean sequence data from sporocarps contaminated by other fungi, perhaps due to dilution resulting from low DNA yield. We conclude that conventional extractions are often unnecessary for routine DNA sequencing or genotyping of fungi and oomycetes, and recommend simpler strategies where source materials and intended applications warrant such use. © 2012 Blackwell Publishing Ltd.
Van Den Berg, Patricia; Body, Richard
2018-03-01
The objective of this systematic review was to summarise the current evidence on the diagnostic accuracy of the HEART score for predicting major adverse cardiac events in patients presenting with undifferentiated chest pain to the emergency department. Two investigators independently searched Medline, Embase and Cochrane databases between 2008 and May 2016 identifying eligible studies providing diagnostic accuracy data on the HEART score for predicting major adverse cardiac events as the primary outcome. For the 12 studies meeting inclusion criteria, study characteristics and diagnostic accuracy measures were systematically extracted and study quality assessed using the QUADAS-2 tool. After quality assessment, nine studies including data from 11,217 patients were combined in the meta-analysis applying a generalised linear mixed model approach with random effects assumption (Stata 13.1). In total, 15.4% of patients (range 7.3-29.1%) developed major adverse cardiac events after a mean of 6 weeks' follow-up. Among patients categorised as 'low risk' and suitable for early discharge (HEART score 0-3), the pooled incidence of 'missed' major adverse cardiac events was 1.6%. The pooled sensitivity and specificity of the HEART score for predicting major adverse cardiac events were 96.7% (95% confidence interval (CI) 94.0-98.2%) and 47.0% (95% CI 41.0-53.5%), respectively. Patients with a HEART score of 0-3 are at low risk of incident major adverse cardiac events. As 3.3% of patients with major adverse cardiac events are 'missed' by the HEART score, clinicians must ask whether this risk is acceptably low for clinical implementation.
Assessing Disease Class-Specific Diagnostic Ability: A Practical Adaptive Test Approach.
ERIC Educational Resources Information Center
Papa, Frank J.; Schumacker, Randall E.
Measures of the robustness of disease class-specific diagnostic concepts could play a central role in training programs designed to assure the development of diagnostic competence. In the pilot study, the authors used disease/sign-symptom conditional probability estimates, Monte Carlo procedures, and artificial intelligence (AI) tools to create…
A Three-Dimensional Receiver Operator Characteristic Surface Diagnostic Metric
2010-10-01
steps applied for generating the 3D ROC surface diagnostic metrics: 1. Obtain system data: Gain access to a suitable database of system data under...surface, VUSTPR and VUSCCR, can be calculated. This can be accomplished by partitioning the VUSTPR and VUSCCR volumes into polyhedrons as illustrated... polyhedron volumes to produce VUSTPR and VUSCCR. In the example given in Figures 7 and 8 a logarithmic scaling has been applied to the TL axis. This places
Developing user-friendly habitat suitability tools from regional stream fish survey data
Zorn, T.G.; Seelbach, P.; Wiley, M.J.
2011-01-01
We developed user-friendly fish habitat suitability tools (plots) for fishery managers in Michigan; these tools are based on driving habitat variables and fish population estimates for several hundred stream sites throughout the state. We generated contour plots to show patterns in fish biomass for over 60 common species (and for 120 species grouped at the family level) in relation to axes of catchment area and low-flow yield (90% exceedance flow divided by catchment area) and also in relation to axes of mean and weekly range of July temperatures. The plots showed distinct patterns in fish habitat suitability at each level of biological organization studied and were useful for quantitatively comparing river sites. We demonstrate how these plots can be used to support stream management, and we provide examples pertaining to resource assessment, trout stocking, angling regulations, chemical reclamation of marginal trout streams, indicator species, instream flow protection, and habitat restoration. These straightforward and effective tools are electronically available so that managers can easily access and incorporate them into decision protocols and presentations.
A vibroacoustic diagnostic system as an element improving road transport safety.
Komorska, Iwona
2013-01-01
Mechanical defects of a vehicle driving system can be dangerous on the road. Diagnostic systems, which monitor operations of electric and electronic elements and devices of vehicles, are continuously developed and improved, while defects of mechanical systems are still not managed properly. This article proposes supplementing existing on-board diagnostics with a system of diagnosing selected defects to minimize their impact. It presents a method of diagnosing mechanical defects of the engine, gearbox and other elements of the driving system on the basis of a model of the vibration signal obtained adaptively. This method is suitable for engine valves, engine head gasket, main gearbox, joints, etc.
Diagnostic imaging in bovine orthopedics.
Kofler, Johann; Geissbühler, Urs; Steiner, Adrian
2014-03-01
Although a radiographic unit is not standard equipment for bovine practitioners in hospital or field situations, ultrasound machines with 7.5-MHz linear transducers have been used in bovine reproduction for many years, and are eminently suitable for evaluation of orthopedic disorders. The goal of this article is to encourage veterinarians to use radiology and ultrasonography for the evaluation of bovine orthopedic disorders. These diagnostic imaging techniques improve the likelihood of a definitive diagnosis in every bovine patient but especially in highly valuable cattle, whose owners demand increasingly more diagnostic and surgical interventions that require high-level specialized techniques. Copyright © 2014 Elsevier Inc. All rights reserved.
Perrot, Serge; Peixoto, Mariana; Dieudé, Philippe; Hachulla, Eric; Avouac, Jerome; Ottaviani, Sebastien; Allanore, Yannick
2017-01-01
Fibromyalgia (FM) may occur with rheumatoid arthritis (RA) and systemic sclerosis (SSc), and debate remains about its diagnosis. We aimed to use three FM tools (a screening tool (FiRST), diagnostic criteria (ACR 1990 and revised 2010), to compare FM prevalence between RA and SSc patients, to describe the phenotypes of patients with comorbid FM, and to analyze links between FM and secondary Sjögren's syndrome (SS). Consecutive adult patients with confirmed RA or SSc from four university hospitals were tested with the three FM tools. FiRST detected FM in 22.6% of the 172 RA patients, with confirmation in 22.1% (ACR1990) and 19.1% (ACR2010). ACR1990FM+ RA patients had more diffuse pain, whereas ACR2010FM+ RA patients had higher BMI and pain intensity, more diffuse pain, active disease, disability, and associated SS. FiRST detected FM in 27.8% of the 122 SSc patients, with confirmation in 30.3% (ACR1990) and 23.7% (ACR2010). ACR1990FM+ SSc patients had greater disability and pain intensity, and more diffuse pain, whereas ACR2010FM+ SSc patients had higher BMI, pain intensity, more disability and diffuse pain, and associated SS. Correlations between FM diagnostic and screening tool results were modest in both conditions. Secondary SS was associated with comorbid FM. The prevalence of FM is high in SSc and RA, whatever the FM diagnostic tool used. Secondary SS is associated with FM in both RA and SSc. The revised ACR 2010 FM criteria and FiRST screening tool reveal specific phenotypes potentially useful for improving disease management.
A manifesto for cardiovascular imaging: addressing the human factor†
Fraser, Alan G
2017-01-01
Abstract Our use of modern cardiovascular imaging tools has not kept pace with their technological development. Diagnostic errors are common but seldom investigated systematically. Rather than more impressive pictures, our main goal should be more precise tests of function which we select because their appropriate use has therapeutic implications which in turn have a beneficial impact on morbidity or mortality. We should practise analytical thinking, use checklists to avoid diagnostic pitfalls, and apply strategies that will reduce biases and avoid overdiagnosis. We should develop normative databases, so that we can apply diagnostic algorithms that take account of variations with age and risk factors and that allow us to calculate pre-test probability and report the post-test probability of disease. We should report the imprecision of a test, or its confidence limits, so that reference change values can be considered in daily clinical practice. We should develop decision support tools to improve the quality and interpretation of diagnostic imaging, so that we choose the single best test irrespective of modality. New imaging tools should be evaluated rigorously, so that their diagnostic performance is established before they are widely disseminated; this should be a shared responsibility of manufacturers with clinicians, leading to cost-effective implementation. Trials should evaluate diagnostic strategies against independent reference criteria. We should exploit advances in machine learning to analyse digital data sets and identify those features that best predict prognosis or responses to treatment. Addressing these human factors will reap benefit for patients, while technological advances continue unpredictably. PMID:29029029
Simulation of light transport in arthritic- and non-arthritic human fingers
NASA Astrophysics Data System (ADS)
Milanic, Matija; Paluchowski, Lukasz A.; Randeberg, Lise L.
2014-03-01
Rheumatoid arthritis is a disease that frequently leads to joint destruction. It has high incidence rates worldwide, and the disease significantly reduces patient's quality of life due to pain, swelling and stiffness of the affected joints. Early diagnosis is necessary to improve course of the disease, therefore sensitive and accurate diagnostic tools are required. Optical imaging techniques have capability for early diagnosis and monitoring of arthritis. As compared to conventional diagnostic techniques optical technique is a noninvasive, noncontact and fast way of collecting diagnostic information. However, a realistic model of light transport in human joints is needed for understanding and developing of such optical diagnostic tools. The aim of this study is to develop a 3D numerical model of light transport in a human finger. The model will guide development of a hyperspectral imaging (HSI) diagnostic modality for arthritis in human fingers. The implemented human finger geometry is based on anatomical data. Optical data of finger tissues are adjusted to represent either an arthritic or an unaffected finger. The geometry and optical data serve as input into a 3D Monte Carlo method, which calculate diffuse reflectance, transmittance and absorbed energy distributions. The parameters of the model are optimized based on HIS-measurements of human fingers. The presented model serves as an important tool for understanding and development of HSI as an arthritis diagnostic modality. Yet, it can be applied to other optical techniques and finger diseases.
Optical biosensor technologies for molecular diagnostics at the point-of-care
NASA Astrophysics Data System (ADS)
Schotter, Joerg; Schrittwieser, Stefan; Muellner, Paul; Melnik, Eva; Hainberger, Rainer; Koppitsch, Guenther; Schrank, Franz; Soulantika, Katerina; Lentijo-Mozo, Sergio; Pelaz, Beatriz; Parak, Wolfgang; Ludwig, Frank; Dieckhoff, Jan
2015-05-01
Label-free optical schemes for molecular biosensing hold a strong promise for point-of-care applications in medical research and diagnostics. Apart from diagnostic requirements in terms of sensitivity, specificity, and multiplexing capability, also other aspects such as ease of use and manufacturability have to be considered in order to pave the way to a practical implementation. We present integrated optical waveguide as well as magnetic nanoparticle based molecular biosensor concepts that address these aspects. The integrated optical waveguide devices are based on low-loss photonic wires made of silicon nitride deposited by a CMOS compatible plasma-enhanced chemical vapor deposition (PECVD) process that allows for backend integration of waveguides on optoelectronic CMOS chips. The molecular detection principle relies on evanescent wave sensing in the 0.85 μm wavelength regime by means of Mach-Zehnder interferometers, which enables on-chip integration of silicon photodiodes and, thus, the realization of system-on-chip solutions. Our nanoparticle-based approach is based on optical observation of the dynamic response of functionalized magneticcore/ noble-metal-shell nanorods (`nanoprobes') to an externally applied time-varying magnetic field. As target molecules specifically bind to the surface of the nanoprobes, the observed dynamics of the nanoprobes changes, and the concentration of target molecules in the sample solution can be quantified. This approach is suitable for dynamic real-time measurements and only requires minimal sample preparation, thus presenting a highly promising point-of-care diagnostic system. In this paper, we present a prototype of a diagnostic device suitable for highly automated sample analysis by our nanoparticle-based approach.
Fontela, Patricia Scolari; Pant Pai, Nitika; Schiller, Ian; Dendukuri, Nandini; Ramsay, Andrew; Pai, Madhukar
2009-11-13
Poor methodological quality and reporting are known concerns with diagnostic accuracy studies. In 2003, the QUADAS tool and the STARD standards were published for evaluating the quality and improving the reporting of diagnostic studies, respectively. However, it is unclear whether these tools have been applied to diagnostic studies of infectious diseases. We performed a systematic review on the methodological and reporting quality of diagnostic studies in TB, malaria and HIV. We identified diagnostic accuracy studies of commercial tests for TB, malaria and HIV through a systematic search of the literature using PubMed and EMBASE (2004-2006). Original studies that reported sensitivity and specificity data were included. Two reviewers independently extracted data on study characteristics and diagnostic accuracy, and used QUADAS and STARD to evaluate the quality of methods and reporting, respectively. Ninety (38%) of 238 articles met inclusion criteria. All studies had design deficiencies. Study quality indicators that were met in less than 25% of the studies included adequate description of withdrawals (6%) and reference test execution (10%), absence of index test review bias (19%) and reference test review bias (24%), and report of uninterpretable results (22%). In terms of quality of reporting, 9 STARD indicators were reported in less than 25% of the studies: methods for calculation and estimates of reproducibility (0%), adverse effects of the diagnostic tests (1%), estimates of diagnostic accuracy between subgroups (10%), distribution of severity of disease/other diagnoses (11%), number of eligible patients who did not participate in the study (14%), blinding of the test readers (16%), and description of the team executing the test and management of indeterminate/outlier results (both 17%). The use of STARD was not explicitly mentioned in any study. Only 22% of 46 journals that published the studies included in this review required authors to use STARD. Recently published diagnostic accuracy studies on commercial tests for TB, malaria and HIV have moderate to low quality and are poorly reported. The more frequent use of tools such as QUADAS and STARD may be necessary to improve the methodological and reporting quality of future diagnostic accuracy studies in infectious diseases.
Fontela, Patricia Scolari; Pant Pai, Nitika; Schiller, Ian; Dendukuri, Nandini; Ramsay, Andrew; Pai, Madhukar
2009-01-01
Background Poor methodological quality and reporting are known concerns with diagnostic accuracy studies. In 2003, the QUADAS tool and the STARD standards were published for evaluating the quality and improving the reporting of diagnostic studies, respectively. However, it is unclear whether these tools have been applied to diagnostic studies of infectious diseases. We performed a systematic review on the methodological and reporting quality of diagnostic studies in TB, malaria and HIV. Methods We identified diagnostic accuracy studies of commercial tests for TB, malaria and HIV through a systematic search of the literature using PubMed and EMBASE (2004–2006). Original studies that reported sensitivity and specificity data were included. Two reviewers independently extracted data on study characteristics and diagnostic accuracy, and used QUADAS and STARD to evaluate the quality of methods and reporting, respectively. Findings Ninety (38%) of 238 articles met inclusion criteria. All studies had design deficiencies. Study quality indicators that were met in less than 25% of the studies included adequate description of withdrawals (6%) and reference test execution (10%), absence of index test review bias (19%) and reference test review bias (24%), and report of uninterpretable results (22%). In terms of quality of reporting, 9 STARD indicators were reported in less than 25% of the studies: methods for calculation and estimates of reproducibility (0%), adverse effects of the diagnostic tests (1%), estimates of diagnostic accuracy between subgroups (10%), distribution of severity of disease/other diagnoses (11%), number of eligible patients who did not participate in the study (14%), blinding of the test readers (16%), and description of the team executing the test and management of indeterminate/outlier results (both 17%). The use of STARD was not explicitly mentioned in any study. Only 22% of 46 journals that published the studies included in this review required authors to use STARD. Conclusion Recently published diagnostic accuracy studies on commercial tests for TB, malaria and HIV have moderate to low quality and are poorly reported. The more frequent use of tools such as QUADAS and STARD may be necessary to improve the methodological and reporting quality of future diagnostic accuracy studies in infectious diseases. PMID:19915664
Optical diagnostics in the oral cavity: an overview.
Wilder-Smith, P; Holtzman, J; Epstein, J; Le, A
2010-11-01
As the emphasis shifts from damage mitigation to disease prevention or reversal of early disease in the oral cavity, the need for sensitive and accurate detection and diagnostic tools become more important. Many novel and emergent optical diagnostic modalities for the oral cavity are becoming available to clinicians with a variety of desirable attributes including: (i) non-invasiveness, (ii) absence of ionizing radiation, (iii) patient-friendliness, (iv) real-time information (v) repeatability, and (vi) high-resolution surface and subsurface images. In this article, the principles behind optical diagnostic approaches, their feasibility and applicability for imaging soft and hard tissues, and their potential usefulness as a tool in the diagnosis of oral mucosal lesions, dental pathologies, and other dental applications will be reviewed. The clinical applications of light-based imaging technologies in the oral cavity and of their derivative devices will be discussed to provide the reader with a comprehensive understanding of emergent diagnostic modalities. © 2010 John Wiley & Sons A/S.
Pashchenko, Oleksandra; Shelby, Tyler; Banerjee, Tuhina; Santra, Santimukul
2018-06-18
Each year, infectious diseases are responsible for millions of deaths, most of which occur in the rural areas of developing countries. Many of the infectious disease diagnostic tools used today require a great deal of time, a laboratory setting, and trained personnel. Due to this, the need for effective point-of-care (POC) diagnostic tools is greatly increasing with an emphasis on affordability, portability, sensitivity, specificity, timeliness, and ease of use. In this Review, we discuss the various diagnostic modalities that have been utilized toward this end and are being further developed to create POC diagnostic technologies, and we focus on potential effectiveness in resource-limited settings. The main modalities discussed herein are optical-, electrochemical-, magnetic-, and colorimetric-based modalities utilized in diagnostic technologies for infectious diseases. Each of these modalities feature pros and cons when considering application in POC settings but, overall, reveal a promising outlook for the future of this field of technological development.
Özenci, Volkan; Patel, Robin; Ullberg, Måns; Strålin, Kristoffer
2018-01-18
Although there are several US Food and Drug Administration (FDA)-approved/cleared molecular microbiology diagnostics for direct analysis of patient samples, all are single target or panel-based tests. There is no FDA-approved/cleared diagnostic for broad microbial detection. Polymerase chain reaction (PCR)/electrospray ionization-mass spectrometry (PCR/ESI-MS), commercialized as the IRIDICA system (Abbott) and formerly PLEX-ID, had been under development for over a decade and had become CE-marked and commercially available in Europe in 2014. Capable of detecting a large number of microorganisms, it was under review at the FDA when, in April 2017, Abbott discontinued it. This turn of events represents not only the loss of a potential diagnostic tool for infectious diseases but may be a harbinger of similar situations with other emerging and expensive microbial diagnostics, especially genomic tests. © The Author(s) 2017. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail: journals.permissions@oup.com.
The rapid evolution of molecular genetic diagnostics in neuromuscular diseases.
Volk, Alexander E; Kubisch, Christian
2017-10-01
The development of massively parallel sequencing (MPS) has revolutionized molecular genetic diagnostics in monogenic disorders. The present review gives a brief overview of different MPS-based approaches used in clinical diagnostics of neuromuscular disorders (NMDs) and highlights their advantages and limitations. MPS-based approaches like gene panel sequencing, (whole) exome sequencing, (whole) genome sequencing, and RNA sequencing have been used to identify the genetic cause in NMDs. Although gene panel sequencing has evolved as a standard test for heterogeneous diseases, it is still debated, mainly because of financial issues and unsolved problems of variant interpretation, whether genome sequencing (and to a lesser extent also exome sequencing) of single patients can already be regarded as routine diagnostics. However, it has been shown that the inclusion of parents and additional family members often leads to a substantial increase in the diagnostic yield in exome-wide/genome-wide MPS approaches. In addition, MPS-based RNA sequencing just enters the research and diagnostic scene. Next-generation sequencing increasingly enables the detection of the genetic cause in highly heterogeneous diseases like NMDs in an efficient and affordable way. Gene panel sequencing and family-based exome sequencing have been proven as potent and cost-efficient diagnostic tools. Although clinical validation and interpretation of genome sequencing is still challenging, diagnostic RNA sequencing represents a promising tool to bypass some hurdles of diagnostics using genomic DNA.
Langley, Ivor; Doulla, Basra; Lin, Hsien-Ho; Millington, Kerry; Squire, Bertie
2012-09-01
The introduction and scale-up of new tools for the diagnosis of Tuberculosis (TB) in developing countries has the potential to make a huge difference to the lives of millions of people living in poverty. To achieve this, policy makers need the information to make the right decisions about which new tools to implement and where in the diagnostic algorithm to apply them most effectively. These decisions are difficult as the new tools are often expensive to implement and use, and the health system and patient impacts uncertain, particularly in developing countries where there is a high burden of TB. The authors demonstrate that a discrete event simulation model could play a significant part in improving and informing these decisions. The feasibility of linking the discrete event simulation to a dynamic epidemiology model is also explored in order to take account of longer term impacts on the incidence of TB. Results from two diagnostic districts in Tanzania are used to illustrate how the approach could be used to improve decisions.
Ecoclimatic indicators to study climate suitability of areas for the cultivation of specific crops
NASA Astrophysics Data System (ADS)
Caubel, J.; Garcia de Cortazar Atauri, I.; Cufi, J.; Huard, F.; Launay, M.; Ripoche, D.; Graux, A.; deNoblet, N.
2013-12-01
Climatic conditions play a fundamental role in the suitability of geographical areas for cropping. In the context of climate change, we could expect changes in overall climatic conditions and so, on the suitability for cropping. Therefore, assessing the future climate suitability of areas for cropping is decisive for anticipating agriculture in a given area. Moreover, it is crucial to have access to the split up information concerning the effect of climate on the achievement of the main ecophysiological processes and cultural practices taking place during the crop cycle. In this way, stakeholders can envisage land use adaptations under climate change conditions, such as changes in cultural practices or development of new varieties for example. We proposed an aggregation tool of ecoclimatic indicators to design evaluation trees of climate suitability of areas for cropping, GETARI (Generic Evaluation Tool of Ecoclimatic Indicators). It calculates an overall climate suitability index at the annual scale, from a designed evaluation tree. This aggregation tool allows to characterize climate suitability according to crop ecophysiology, grain/fruit quality or crop management. GETARI proposes the major ecophysiological processes and cultural practices taking place during phenological periods, together with the climatic effects that are known to affect their achievement. The climatic effects on the ecophysiological processes (or cultural practices) during phenological periods are captured by the ecoclimatic indicators, which are agroclimatic indicators calculated over phenological periods. They give information about crop response to climate through ecophysiological or agronomic thresholds. Those indices of suitability are normalized and aggregated according to aggregation rules in order to compute an overall climate index. In order to illustrate how GETARI can be used, we designed evaluation trees in order to study the climate suitability for maize cropping regarding ecophysiology, for wheat cropping regarding its management and for grape cropping regarding its quality. The designed evaluation trees were developed in accordance with expert assessment and were applied in some past climatic conditions in France to verify their consistence. To conclude, the use of indicators does not replace models but represent additional tools for understanding and spatializing some results obtained by models. Their use can provide information about suitability of geographical areas for cropping in future climatic conditions and can enable to minimize the risk of crop failure. This work is carried out under the research program ORACLE (Opportunities and Risks of Agrosystems & forests in response to CLimate, socio-economic and policy changEs in France (and Europe).
LETTER TO THE EDITOR: Response to 'Patient dose measurements in radiological practices'
NASA Astrophysics Data System (ADS)
Zoetelief, J.; Wambersie, A.
2006-06-01
A lack of suitable dosimetric quantities for application in diagnostic radiology is noted by Dr Moores. It is concluded by Dr Moores that it is not possible to adhere to the basic principles of the International Commission on Radiation Units and Measurements (ICRU) regarding patient dosimetry in diagnostic radiology due to the extremely wide variety of quantities and units employed. The conclusion of the ICRU on similar observations, however, was that there is a need for harmonization of quantities and terminology for dosimetry in diagnostic and interventional radiology and they established a Report Committee with the aim of formulating an ICRU report on 'dosimetric procedures in diagnostic radiology'. The report produced by this committee entitled 'Patient dosimetry for x rays used in medical imaging' was accepted for publication in December 2005 and is currently at press, and may serve to improve the current situation with regard to patient dose measurement in diagnostic and interventional radiology.
Software engineering techniques and CASE tools in RD13
NASA Astrophysics Data System (ADS)
Buono, S.; Gaponenko, I.; Jones, R.; Khodabandeh, A.; Mapelli, L.; Mornacchi, G.; Prigent, D.; Sanchez-Corral, E.; Skiadelli, M.; Toppers, A.; Duval, P. Y.; Ferrato, D.; Le Van Suu, A.; Qian, Z.; Rondot, C.; Ambrosini, G.; Fumagalli, G.; Polesello, G.; Aguer, M.; Huet, M.
1994-12-01
The RD13 project was approved in April 1991 for the development of a scalable data-taking system suitable for hosting various LHC studies. One of its goals is the exploitation of software engineering techniques, in order to indicate their overall suitability for data acquisition (DAQ), software design and implementation. This paper describes how such techniques have been applied to the development of components of the RD13 DAQ used in test-beam runs at CERN. We describe our experience with the Artifex CASE tool and its associated methodology. The issues raised when code generated by a CASE tool has to be integrated into an existing environment are also discussed.
2014-01-01
Background Accurate diagnosis of malaria infections remains challenging, especially in the identification of submicroscopic infections. New molecular diagnostic tools that are inexpensive, sensitive enough to detect low-level infections and suitable in laboratory settings of resource-limited countries are required for malaria control and elimination programmes. Here the diagnostic potential of a recently developed photo-induced electron transfer fluorogenic primer (PET) real-time polymerase chain reaction (PCR) called PET-PCR was investigated. This study aimed to (i) evaluate the use of this assay as a method for the detection of both Plasmodium falciparum and other Plasmodium species infections in a developing country’s diagnostic laboratory; and, (ii) determine the assay’s sensitivity and specificity compared to a nested 18S rRNA PCR. Methods Samples used in this study were obtained from a previous study conducted in the region of Iringa, Tanzania. A total of 303 samples from eight health facilities in Tanzania were utilized for this evaluation. All samples were screened using the multiplex PET-PCR assay designed to detect Plasmodium genus and P. falciparum initially in laboratory in Tanzania and then repeated at a reference laboratory at the CDC in the USA. Microscopy data was available for all the 303 samples. A subset of the samples were tested in a blinded fashion to find the sensitivity and specificity of the PET-PCR compared to the nested 18S rRNA PCR. Results Compared to microscopy, the PET-PCR assay was 59% more sensitive in detecting P. falciparum infections. The observed sensitivity and specificity were 100% (95% confidence interval (CI0.95) = 94-100%) and (CI0.95 = 96-100%), respectively, for the PET-PCR assay when compared to nested 18S rRNA PCR. When compared to 18S rRNA PCR, microscopy had a low sensitivity of 40% (CI0.95 = 23-61%) and specificity of 100% (CI0.95 = 96-100%). The PET-PCR results performed in the field laboratory in Tanzania were in 100% concordance with the results obtained at the reference laboratory in the USA. Conclusion The PET-PCR is a new molecular diagnostic tool with similar performance characteristics as commonly used PCR methods that is less expensive, easy to use, and amiable to large scale-surveillance studies in developing country settings. PMID:24467985
Bhattacharyya, Rahul; Davidson, Donald J; Sugand, Kapil; Bartlett, Matthew J; Bhattacharya, Rajarshi; Gupte, Chinmay M
2017-10-04
Virtual-reality and cadaveric simulations are expensive and not readily accessible. Innovative and accessible training adjuncts are required to help to meet training needs. Cognitive task analysis has been used extensively to train pilots and in other surgical specialties. However, the use of cognitive task analyses within orthopaedics is in its infancy. The purpose of this study was to evaluate the effectiveness of a novel cognitive task analysis tool to train novice surgeons in diagnostic knee arthroscopy in high-fidelity, phantom-limb simulation. Three expert knee surgeons were interviewed independently to generate a list of technical steps, decision points, and errors for diagnostic knee arthroscopy. A modified Delphi technique was used to generate the final cognitive task analysis. A video and a voiceover were recorded for each phase of this procedure. These were combined to produce the Imperial Knee Arthroscopy Cognitive Task Analysis (IKACTA) tool that utilizes written and audiovisual stimuli to describe each phase of a diagnostic knee arthroscopy. In this double-blinded, randomized controlled trial, a power calculation was performed prior to recruitment. Sixteen novice orthopaedic trainees who performed ≤10 diagnostic knee arthroscopies were randomized into 2 equal groups. The intervention group (IKACTA group) was given the IKACTA tool and the control group had no additional learning material. They were assessed objectively (validated Arthroscopic Surgical Skill Evaluation Tool [ASSET] global rating scale) on a high-fidelity, phantom-knee simulator. All participants, using the Likert rating scale, subjectively rated the tool. The mean ASSET score (and standard deviation) was 19.5 ± 3.7 points in the IKACTA group and 10.6 ± 2.3 points in the control group, resulting in an improvement of 8.9 points (95% confidence interval, 7.6 to 10.1 points; p = 0.002); the score was determined as 51.3% (19.5 of 38) for the IKACTA group, 27.9% (10.6 of 38) for the control group, and 23.4% (8.9 of 38) for the improvement. All participants agreed that the cognitive task analysis learning tool was a useful training adjunct to learning in the operating room. To our knowledge, this is the first cognitive task analysis in diagnostic knee arthroscopy that is user-friendly and inexpensive and has demonstrated significant benefits in training. The IKACTA will provide trainees with a demonstrably strong foundation in diagnostic knee arthroscopy that will flatten learning curves in both technical skills and decision-making.
Percutaneous cavitary lavage in the diagnosis of pulmonary cavities
Findik, Serhat; Ozmen, Zafer; Atici, Atilla Guven; Akan, Huseyin
2013-01-01
Objective To investigate diagnostic significance of percutaneous cavitary lavage (PCL) in differential diagnosis of benign and malignant pulmonary cavitary lesions. Methods An alternative diagnostic method called PCL was performed on 16 patients having peripherally located pulmonary cavitary lesions with thin walls which were not suitable for tissue biopsy and whose diagnosis could not be made by sputum examination and bronchoscopic procedures. A 22-gauge needle was inserted into the cavity under computed tomography (CT) guidance. Saline was injected through the needle and then aspirated. The specimen was examined cytologically and microbiologically. Results PCL could make a correct diagnosis in 12 of 16 patients (75%). In three patients (18.7%) appropriate specimen could not be taken. Diagnostic sensitivity and specificity of PCL for malignant-benign differentiation was 80% and 100%, respectively. The accuracy of PCL for this differentiation was 92.3%. There was only one complication, a small pneumothorax resolved without any intervention. Conclusions PCL is an alternative method in the differential diagnosis of thin walled pulmonary cavitary lesions especially for patients whose diagnosis could not be made by sputum and bronchoscopic procedures and who are not suitable for cutting needle biopsy. PMID:23991300
Diagnosis of Neisseria gonorrhoeae Using Molecular Beacon
Patel, Achchhe Lal; Sonkar, Subash Chandra; Kumari, Indu; Saluja, Daman
2015-01-01
Neisseria gonorrhoeae is an important sexually transmitted diseases (STD) causing pathogen worldwide. Due to absence of an affordable diagnostic assay, routine screening of gonococcal infection becomes impossible in developing countries where infection rates are maximum. Treatment is given on the basis of symptoms alone which leads to spread of infection. Thus, development of a rapid, sensitive, specific, and PCR based visual diagnostic assay suitable for developing countries, required for better disease management, is aimed at in present study. Endocervical swabs were collected from patients visiting gynecology department of various hospitals in Delhi. In-house PCR based assay was developed and modified to visual assay using molecular beacon for end-point detection. It was evaluated against Roche AMPLICOR NG kit and rmp gene. Specificity of beacon was confirmed by competition experiments. Diagnostic test was 98.21% specific and 99.59% sensitive whereas negative and positive predicted value were 99.40% and 98.78%, respectively. We also observed that twice the concentration (2X) of premix was stable at 4°C for 4 months and dry swab samples gave concordant results with that of wet swabs. These features make the test best suitable for routine diagnosis of genital infections in developing countries. PMID:25802857
NASA Technical Reports Server (NTRS)
Dempsey, Paula J.
2003-01-01
A diagnostic tool for detecting damage to gears was developed. Two different measurement technologies, oil debris analysis and vibration were integrated into a health monitoring system for detecting surface fatigue pitting damage on gears. This integrated system showed improved detection and decision-making capabilities as compared to using individual measurement technologies. This diagnostic tool was developed and evaluated experimentally by collecting vibration and oil debris data from fatigue tests performed in the NASA Glenn Spur Gear Fatigue Rig. An oil debris sensor and the two vibration algorithms were adapted as the diagnostic tools. An inductance type oil debris sensor was selected for the oil analysis measurement technology. Gear damage data for this type of sensor was limited to data collected in the NASA Glenn test rigs. For this reason, this analysis included development of a parameter for detecting gear pitting damage using this type of sensor. The vibration data was used to calculate two previously available gear vibration diagnostic algorithms. The two vibration algorithms were selected based on their maturity and published success in detecting damage to gears. Oil debris and vibration features were then developed using fuzzy logic analysis techniques, then input into a multi sensor data fusion process. Results show combining the vibration and oil debris measurement technologies improves the detection of pitting damage on spur gears. As a result of this research, this new diagnostic tool has significantly improved detection of gear damage in the NASA Glenn Spur Gear Fatigue Rigs. This research also resulted in several other findings that will improve the development of future health monitoring systems. Oil debris analysis was found to be more reliable than vibration analysis for detecting pitting fatigue failure of gears and is capable of indicating damage progression. Also, some vibration algorithms are as sensitive to operational effects as they are to damage. Another finding was that clear threshold limits must be established for diagnostic tools. Based on additional experimental data obtained from the NASA Glenn Spiral Bevel Gear Fatigue Rig, the methodology developed in this study can be successfully implemented on other geared systems.
Hybrid Kalman Filter: A New Approach for Aircraft Engine In-Flight Diagnostics
NASA Technical Reports Server (NTRS)
Kobayashi, Takahisa; Simon, Donald L.
2006-01-01
In this paper, a uniquely structured Kalman filter is developed for its application to in-flight diagnostics of aircraft gas turbine engines. The Kalman filter is a hybrid of a nonlinear on-board engine model (OBEM) and piecewise linear models. The utilization of the nonlinear OBEM allows the reference health baseline of the in-flight diagnostic system to be updated to the degraded health condition of the engines through a relatively simple process. Through this health baseline update, the effectiveness of the in-flight diagnostic algorithm can be maintained as the health of the engine degrades over time. Another significant aspect of the hybrid Kalman filter methodology is its capability to take advantage of conventional linear and nonlinear Kalman filter approaches. Based on the hybrid Kalman filter, an in-flight fault detection system is developed, and its diagnostic capability is evaluated in a simulation environment. Through the evaluation, the suitability of the hybrid Kalman filter technique for aircraft engine in-flight diagnostics is demonstrated.
Training and quality assurance with the Structured Clinical Interview for DSM-IV (SCID-I/P).
Ventura, J; Liberman, R P; Green, M F; Shaner, A; Mintz, J
1998-06-15
Accuracy in psychiatric diagnosis is critical for evaluating the suitability of the subjects for entry into research protocols and for establishing comparability of findings across study sites. However, training programs in the use of diagnostic instruments for research projects are not well systematized. Furthermore, little information has been published on the maintenance of interrater reliability of diagnostic assessments. At the UCLA Research Center for Major Mental Illnesses, a Training and Quality Assurance Program for SCID interviewers was used to evaluate interrater reliability and diagnostic accuracy. Although clinically experienced interviewers achieved better interrater reliability and overall diagnostic accuracy than neophyte interviewers, both groups were able to achieve and maintain high levels of interrater reliability, diagnostic accuracy, and interviewer skill. At the first quality assurance check after training, there were no significant differences between experienced and neophyte interviewers in interrater reliability or diagnostic accuracy. Standardization of training and quality assurance procedures within and across research projects may make research findings from study sites more comparable.
Leithner, Doris; Mahmoudi, Scherwin; Wichmann, Julian L; Martin, Simon S; Lenga, Lukas; Albrecht, Moritz H; Booz, Christian; Arendt, Christophe T; Beeres, Martin; D'Angelo, Tommaso; Bodelle, Boris; Vogl, Thomas J; Scholtz, Jan-Erik
2018-02-01
To investigate the impact of traditional (VMI) and noise-optimized virtual monoenergetic imaging (VMI+) algorithms on quantitative and qualitative image quality, and the assessment of stenosis in carotid and intracranial dual-energy CTA (DE-CTA). DE-CTA studies of 40 patients performed on a third-generation 192-slice dual-source CT scanner were included in this retrospective study. 120-kVp image-equivalent linearly-blended, VMI and VMI+ series were reconstructed. Quantitative analysis included evaluation of contrast-to-noise ratios (CNR) of the aorta, common carotid artery, internal carotid artery, middle cerebral artery, and basilar artery. VMI and VMI+ with highest CNR, and linearly-blended series were rated qualitatively. Three radiologists assessed artefacts and suitability for evaluation at shoulder height, carotid bifurcation, siphon, and intracranial using 5-point Likert scales. Detection and grading of stenosis were performed at carotid bifurcation and siphon. Highest CNR values were observed for 40-keV VMI+ compared to 65-keV VMI and linearly-blended images (P < 0.001). Artefacts were low in all qualitatively assessed series with excellent suitability for supraaortic artery evaluation at shoulder and bifurcation height. Suitability was significantly higher in VMI+ and VMI compared to linearly-blended images for intracranial and ICA assessment (P < 0.002). VMI and VMI+ showed excellent accordance for detection and grading of stenosis at carotid bifurcation and siphon with no differences in diagnostic performance. 40-keV VMI+ showed improved quantitative image quality compared to 65-keV VMI and linearly-blended series in supraaortic DE-CTA. VMI and VMI+ provided increased suitability for carotid and intracranial artery evaluation with excellent assessment of stenosis, but did not translate into increased diagnostic performance. Copyright © 2017 Elsevier B.V. All rights reserved.
Energetic particle instabilities in fusion plasmas
NASA Astrophysics Data System (ADS)
Sharapov, S. E.; Alper, B.; Berk, H. L.; Borba, D. N.; Breizman, B. N.; Challis, C. D.; Classen, I. G. J.; Edlund, E. M.; Eriksson, J.; Fasoli, A.; Fredrickson, E. D.; Fu, G. Y.; Garcia-Munoz, M.; Gassner, T.; Ghantous, K.; Goloborodko, V.; Gorelenkov, N. N.; Gryaznevich, M. P.; Hacquin, S.; Heidbrink, W. W.; Hellesen, C.; Kiptily, V. G.; Kramer, G. J.; Lauber, P.; Lilley, M. K.; Lisak, M.; Nabais, F.; Nazikian, R.; Nyqvist, R.; Osakabe, M.; Perez von Thun, C.; Pinches, S. D.; Podesta, M.; Porkolab, M.; Shinohara, K.; Schoepf, K.; Todo, Y.; Toi, K.; Van Zeeland, M. A.; Voitsekhovich, I.; White, R. B.; Yavorskij, V.; TG, ITPA EP; Contributors, JET-EFDA
2013-10-01
Remarkable progress has been made in diagnosing energetic particle instabilities on present-day machines and in establishing a theoretical framework for describing them. This overview describes the much improved diagnostics of Alfvén instabilities and modelling tools developed world-wide, and discusses progress in interpreting the observed phenomena. A multi-machine comparison is presented giving information on the performance of both diagnostics and modelling tools for different plasma conditions outlining expectations for ITER based on our present knowledge.
Performance Assessment as a Diagnostic Tool for Science Teachers
NASA Astrophysics Data System (ADS)
Kruit, Patricia; Oostdam, Ron; van den Berg, Ed; Schuitema, Jaap
2018-04-01
Information on students' development of science skills is essential for teachers to evaluate and improve their own education, as well as to provide adequate support and feedback to the learning process of individual students. The present study explores and discusses the use of performance assessments as a diagnostic tool for formative assessment to inform teachers and guide instruction of science skills in primary education. Three performance assessments were administered to more than 400 students in grades 5 and 6 of primary education. Students performed small experiments using real materials while following the different steps of the empirical cycle. The mutual relationship between the three performance assessments is examined to provide evidence for the value of performance assessments as useful tools for formative evaluation. Differences in response patterns are discussed, and the diagnostic value of performance assessments is illustrated with examples of individual student performances. Findings show that the performance assessments were difficult for grades 5 and 6 students but that much individual variation exists regarding the different steps of the empirical cycle. Evaluation of scores as well as a more substantive analysis of students' responses provided insight into typical errors that students make. It is concluded that performance assessments can be used as a diagnostic tool for monitoring students' skill performance as well as to support teachers in evaluating and improving their science lessons.
Findeisen, Peter; Neumaier, Michael
2009-01-01
Proteomics analysis has been heralded as a novel tool for identifying new and specific biomarkers that may improve diagnosis and monitoring of various disease states. Recent years have brought a number of proteomics profiling technologies. Although proteomics profiling has resulted in the detection of disease-associated differences and modification of proteins, current proteomics technologies display certain limitations that are hampering the introduction of these new technologies into clinical laboratory diagnostics and routine applications. In this review, we summarize current advances in mass spectrometry based biomarker discovery. The promises and challenges of this new technology are discussed with particular emphasis on diagnostic perspectives of mass-spectrometry based proteomics profiling for malignant diseases.
Microfluidics-Enabled Diagnostic Systems: Markets, Challenges, and Examples.
Becker, Holger; Gärtner, Claudia
2017-01-01
Microfluidics has become an important tool for the commercial product development in diagnostics. This article will focus on current technical demands during the development process such as material and integration challenges. Furthermore, we present data on the diagnostics market as well as examples of microfluidics-enabled systems currently under commercial development or already on the market.
ERIC Educational Resources Information Center
Keiser, Ashley; Reddy, Linda
2013-01-01
The Pediatric Attention Disorders Diagnostic Screener is a multidimensional, computerized screening tool designed to assess attention and global aspects of executive functioning in children at risk for attention disorders. The screener consists of a semi-structured diagnostic interview, brief parent and teacher rating scales, 3 computer-based…
Diagnostics of Pupils' Meta-Subject Competence during Lessons on Mathematics in Secondary Schools
ERIC Educational Resources Information Center
Khuziakhmetova, Anvar N.; Naumova, Marina V.
2016-01-01
The relevance of diagnostic meta-subject competence measures in secondary schools is caused by the fact that the importance of a meta-subject competence formation was officially defined in educational standards, but there are still no qualitative and informative diagnostic tools for this competence development. The purpose of the article is to…
Evaluation of Diagnostic Systems: The Selection of Students at Risk of Academic Difficulties
ERIC Educational Resources Information Center
Smolkowski, Keith; Cummings, Kelli D.
2015-01-01
Diagnostic tools can help schools more consistently and fairly match instructional resources to the needs of their students. To ensure the best educational outcome for each child, diagnostic decision-making systems seek to balance time, clarity, and accuracy. However, recent research notes that many educational decisions tend to be made using…
Scaria, Joy; Sreedharan, Aswathy; Chang, Yung-Fu
2008-01-01
Background Microarrays are becoming a very popular tool for microbial detection and diagnostics. Although these diagnostic arrays are much simpler when compared to the traditional transcriptome arrays, due to the high throughput nature of the arrays, the data analysis requirements still form a bottle neck for the widespread use of these diagnostic arrays. Hence we developed a new online data sharing and analysis environment customised for diagnostic arrays. Methods Microbial Diagnostic Array Workstation (MDAW) is a database driven application designed in MS Access and front end designed in ASP.NET. Conclusion MDAW is a new resource that is customised for the data analysis requirements for microbial diagnostic arrays. PMID:18811969
Scaria, Joy; Sreedharan, Aswathy; Chang, Yung-Fu
2008-09-23
Microarrays are becoming a very popular tool for microbial detection and diagnostics. Although these diagnostic arrays are much simpler when compared to the traditional transcriptome arrays, due to the high throughput nature of the arrays, the data analysis requirements still form a bottle neck for the widespread use of these diagnostic arrays. Hence we developed a new online data sharing and analysis environment customised for diagnostic arrays. Microbial Diagnostic Array Workstation (MDAW) is a database driven application designed in MS Access and front end designed in ASP.NET. MDAW is a new resource that is customised for the data analysis requirements for microbial diagnostic arrays.
Avril, E; Lacroix, S; Vrignaud, B; Moreau-Klein, A; Coste-Burel, M; Launay, E; Gras-Le Guen, C
2016-07-01
We wanted to determine the diagnostic performance of a rapid influenza diagnostic test (RIDT) used bedside in a pediatric emergency department (PED). This was a prospective study over four consecutive winters (2009-2013), comparing the results of a RIDT (QuickVue®) with RT-PCR in children admitted to a PED. Among the 764 children included, we did not observe any significant differences in the diagnostic performance of RIDT except during the H1N1 pandemic. The overall sensitivity of the test was 0.82; the specificity 0.98; the positive and negative likelihood ratios 37.8 and 0.19. The positive and negative post-test probabilities of infection were 98% and 17%. The diagnostic performance was increased for influenza B cases (P = 0.03). RIDTs are suitable for use every winter with few differences in its diagnostic value, except during specific pandemic periods. This test could limit unnecessary complementary exams and guide the prescription of antivirals during influenza epidemic periods in PEDs. Copyright © 2016. Published by Elsevier Inc.
Attaway, David F; Jacobsen, Kathryn H; Falconer, Allan; Manca, Germana; Waters, Nigel M
2016-06-01
Risk maps identifying suitable locations for infection transmission are important for public health planning. Data on dengue infection rates are not readily available in most places where the disease is known to occur. A newly available add-in to Esri's ArcGIS software package, the ArcGIS Predictive Analysis Toolset (PA Tools), was used to identify locations within Africa with environmental characteristics likely to be suitable for transmission of dengue virus. A more accurate, robust, and localized (1 km × 1 km) dengue risk map for Africa was created based on bioclimatic layers, elevation data, high-resolution population data, and other environmental factors that a search of the peer-reviewed literature showed to be associated with dengue risk. Variables related to temperature, precipitation, elevation, and population density were identified as good predictors of dengue suitability. Areas of high dengue suitability occur primarily within West Africa and parts of Central Africa and East Africa, but even in these regions the suitability is not homogenous. This risk mapping technique for an infection transmitted by Aedes mosquitoes draws on entomological, epidemiological, and geographic data. The method could be applied to other infectious diseases (such as Zika) in order to provide new insights for public health officials and others making decisions about where to increase disease surveillance activities and implement infection prevention and control efforts. The ability to map threats to human and animal health is important for tracking vectorborne and other emerging infectious diseases and modeling the likely impacts of climate change. Copyright © 2016 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Schultz, Madeleine; Lawrie, Gwendolyn A.; Bailey, Chantal H.; Bedford, Simon B.; Dargaville, Tim R.; O'Brien, Glennys; Tasker, Roy; Thompson, Christopher D.; Williams, Mark; Wright, Anthony H.
2017-03-01
A multi-institution collaborative team of Australian chemistry education researchers, teaching a total of over 3000 first year chemistry students annually, has explored a tool for diagnosing students' prior conceptions as they enter tertiary chemistry courses. Five core topics were selected and clusters of diagnostic items were assembled linking related concepts in each topic together. An ordered multiple choice assessment strategy was adopted to enable provision of formative feedback to students through combination of the specific distractors that they chose. Concept items were either sourced from existing research instruments or developed by the project team. The outcome is a diagnostic tool consisting of five topic clusters of five concept items that has been delivered in large introductory chemistry classes at five Australian institutions. Statistical analysis of data has enabled exploration of the composition and validity of the instrument including a comparison between delivery of the complete 25 item instrument with subsets of five items, clustered by topic. This analysis revealed that most items retained their validity when delivered in small clusters. Tensions between the assembly, validation and delivery of diagnostic instruments for the purposes of acquiring robust psychometric research data versus their pragmatic use are considered in this study.
Qu, Y J; Yang, Z R; Sun, F; Zhan, S Y
2018-04-10
This paper introduced the Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2), including the development and comparison with the original QUADAS, and illustrated the application of QUADAS-2 in a published paper related to the study on diagnostic accuracy which was included in systematic review and Meta-analysis. QUADAS-2 presented considerable improvement over the original tool. Confused items that included in QUADAS had disappeared and the quality assessment of the original study replaced by the rating of risk on bias and applicability. This was implemented through the description on the four main domains with minimal overlapping and answering the signal questions in each domain. The risk of bias and applicability with 'high','low' or 'unclear' was in line with the risk of bias assessment of intervention studies in Cochrane, so to replace the total score of quality assessment in QUADAS. Meanwhile, QUADAS-2 was also applicable to assess the diagnostic accuracy studies in which follow-up without prognosis was involved in golden standard. It was useful to assess the overall methodological quality of the study despite more time consuming than the original QUADAS. However, QUADAS-2 needs to be modified to apply in comparative studies on diagnostic accuracy and we hope the users would follow the updates and give their feedbacks on line.
Yuan, Haiying; Dollaghan, Christine
2018-03-27
The Diagnostic and Statistical Manual of Mental Disorders, Fifth Edition introduced a new neurodevelopmental disorder, social (pragmatic) communication disorder (SPCD), that is characterized by deficits in 4 areas of communication. Although descriptions of these areas are provided, no assessment tools for SPCD are recommended. The purpose of this study was to examine the extent to which items from measurement tools commonly used in assessing pragmatic language impairment and related disorders might be useful in assessing the characteristics of social communication that define SPCD in the Diagnostic and Statistical Manual of Mental Disorders, Fifth Edition. Based on a literature search, 594 items from assessment tools commonly used to measure social communication abilities in people with pragmatic language impairment were identified. The first author judged whether each item reflected 1, more than 1, or none of the 4 SPCD diagnostic characteristics. After a brief training process, 5 second raters independently mapped subsets of items to the 6 categories. We calculated the percentage of agreement and Cohen's kappa for each pair of raters in assigning items to categories. Percentages of agreement ranged from 76% to 82%, and Cohen's kappa values ranged from .69 to .76, indicating substantial agreement. Sources and item numbers for the 206 items that both raters assigned to the same SPCD feature are provided. These items may provide guidance in assessing SPCD and in designing standardized screening and diagnostic measures for SPCD.
Diagnostic and therapeutic value of laparoscopy for small bowel blunt injuries: A case report.
Addeo, Pietro; Calabrese, Daniela Paola
2011-01-01
Small bowel injuries after blunt abdominal trauma represent both a diagnostic and a therapeutic challenge. Early diagnosis and prompt treatment are necessary in order to avoid a dangerous diagnostic delay. Laparoscopy can represent a diagnostic and therapeutic tool in patients with uncertain clinical symptoms. We report the case of a 25-year-old man, haemodynamically stable, admitted for acute abdominal pain a few hours after a physical assault. Giving the persistence of the abdominal pain and the presence of free fluids at the computed tomography examination, an exploratory laparoscopy was performed. At the laparoscopic exploration, an isolated small bowel perforation was found, 60 cm distal from the ligament of Treitz. The injury was repaired by laparoscopic suturing and the patient was discharged home at postoperative day 3 after an uneventful postoperative course. Laparoscopy represents a valuable tool for patients with small bowel blunt injuries allowing a timely diagnosis and a prompt treatment.
A revolution in diagnostic imaging.
Mamula, Paul W
2003-03-01
In November 1966, Sandy Koufax, the star left-handed pitcher of the Los Angeles Dodgers, retired after spending his final season coping with traumatic arthritis in his elbow, the compounded effects of a sliding injury to his pitching arm the previous season and 12 years of hard throwing.1 Had his career begun a few years later, he might have been able to benefit from the advances in diagnostic imaging and treatment that were introduced at that time. Modern arthroscopy and computed tomography (CT) did not become available until the mid 1970s,2 and the first elbow reconstruction was done by Frank Jobe, MD, about 10 years after Koufax retired.1 Arthroscopy was first used as a diagnostic tool, but it later became a surgical tool, affecting treatment of knees, then, later, shoulders. Since 1973, when The Physician and Sportsmedicine was launched, we have witnessed a revolution in diagnostic imaging and are continuing to see an evolution of modalities.
NASA Astrophysics Data System (ADS)
Shabani, Farzin; Kumar, Lalit; Taylor, Subhashni
2014-11-01
This study set out to model potential date palm distribution under current and future climate scenarios using an emission scenario, in conjunction with two different global climate models (GCMs): CSIRO-Mk3.0 (CS), and MIROC-H (MR), and to refine results based on suitability under four nonclimatic parameters. Areas containing suitable physicochemical soil properties and suitable soil taxonomy, together with land slopes of less than 10° and suitable land uses for date palm ( Phoenix dactylifera) were selected as appropriate refining tools to ensure the CLIMEX results were accurate and robust. Results showed that large regions of Iran are projected as likely to become climatically suitable for date palm cultivation based on the projected scenarios for the years 2030, 2050, 2070, and 2100. The study also showed CLIMEX outputs merit refinement by nonclimatic parameters and that the incremental introduction of each additional parameter decreased the disagreement between GCMs. Furthermore, the study indicated that the least amount of disagreement in terms of areas conducive to date palm cultivation resulted from CS and MR GCMs when the locations of suitable physicochemical soil properties and soil taxonomy were used as refinement tools.
Maini, Rohit; Moscona, John; Katigbak, Paul; Fernandez, Camilo; Sidhu, Gursukhmandeep; Saleh, Qusai; Irimpen, Anand; Samson, Rohan; LeJemtel, Thierry
2017-12-27
Fractional flow reserve (FFR) remains underutilized due to practical concerns related to the need for hyperemic agents. These concerns have prompted the study of instantaneous wave-free ratio (iFR), a vasodilator-free index of coronary stenosis. Non-inferior cardiovascular outcomes have been demonstrated in two recent randomized clinic trials. We performed this meta-analysis to provide a necessary update of the diagnostic accuracy of iFR referenced to FFR based on the addition of eight more recent studies and 3727 more lesions. We searched the PubMed, EMBASE, Central, ProQuest, and Web of Science databases for full text articles published through May 31, 2017 to identify studies addressing the diagnostic accuracy of iFR referenced to FFR≤0.80. The following keywords were used: "instantaneous wave-free ratio" OR "iFR" AND "fractional flow reserve" OR "FFR." In total, 16 studies comprising 5756 lesions were identified. Pooled diagnostic accuracy estimates of iFR versus FFR≤0.80 were: sensitivity, 0.78 (95% CI, 0.76-0.79); specificity, 0.83 (0.81-0.84); positive likelihood ratio, 4.54 (3.85-5.35); negative likelihood ratio, 0.28 (0.24-0.32); diagnostic odds ratio, 17.38 (14.16-21.34); area under the summary receiver-operating characteristic curve, 0.87; and an overall diagnostic accuracy of 0.81 (0.78-0.84). In conclusion, iFR showed excellent agreement with FFR as a resting index of coronary stenosis severity without the undesired effects and cost of hyperemic agents. When considering along with its clinical outcome data and ease of application, the diagnostic accuracy of iFR supports its use as a suitable alternative to FFR for physiology-guided revascularization of moderate coronary stenoses. We performed a meta-analysis of the diagnostic accuracy of iFR referenced to FFR. iFR showed excellent agreement with FFR as a resting index of coronary stenosis severity without the undesired effects and cost of hyperemic agents. This supports its use as a suitable alternative to FFR for physiology-guided revascularization of moderate coronary stenoses. Copyright © 2017. Published by Elsevier Inc.
Tools for surveying and improving the quality of life: people with special needs in focus.
Hoyningen-Süess, Ursula; Oberholzer, David; Stalder, René; Brügger, Urs
2012-01-01
This article seeks to describe online tools for surveying and improving quality of life for people with disabilities living in assisted living centers and special education service organizations. Ensuring a decent quality of life for disabled people is an important welfare state goal. Using well-accepted quality of life conceptions, online diagnostic and planning tools were developed during an Institute for Education, University of Zurich, research project. The diagnostic tools measure, evaluate and analyze disabled people's quality of life. The planning tools identify factors that can affect their quality of life and suggest improvements. Instrument validity and reliability are not tested according to the standard statistical procedures. This will be done at a more advanced stage of the project. Instead, the tool is developed, refined and adjusted in cooperation with practitioners who are constantly judging it according to best practice standards. The tools support staff in assisted living centers and special education service organizations. These tools offer comprehensive resources for surveying, quantifying, evaluating, describing and simulating quality of life elements.
NASA Astrophysics Data System (ADS)
Wright, David; Thyer, Mark; Westra, Seth
2015-04-01
Highly influential data points are those that have a disproportionately large impact on model performance, parameters and predictions. However, in current hydrological modelling practice the relative influence of individual data points on hydrological model calibration is not commonly evaluated. This presentation illustrates and evaluates several influence diagnostics tools that hydrological modellers can use to assess the relative influence of data. The feasibility and importance of including influence detection diagnostics as a standard tool in hydrological model calibration is discussed. Two classes of influence diagnostics are evaluated: (1) computationally demanding numerical "case deletion" diagnostics; and (2) computationally efficient analytical diagnostics, based on Cook's distance. These diagnostics are compared against hydrologically orientated diagnostics that describe changes in the model parameters (measured through the Mahalanobis distance), performance (objective function displacement) and predictions (mean and maximum streamflow). These influence diagnostics are applied to two case studies: a stage/discharge rating curve model, and a conceptual rainfall-runoff model (GR4J). Removing a single data point from the calibration resulted in differences to mean flow predictions of up to 6% for the rating curve model, and differences to mean and maximum flow predictions of up to 10% and 17%, respectively, for the hydrological model. When using the Nash-Sutcliffe efficiency in calibration, the computationally cheaper Cook's distance metrics produce similar results to the case-deletion metrics at a fraction of the computational cost. However, Cooks distance is adapted from linear regression with inherit assumptions on the data and is therefore less flexible than case deletion. Influential point detection diagnostics show great potential to improve current hydrological modelling practices by identifying highly influential data points. The findings of this study establish the feasibility and importance of including influential point detection diagnostics as a standard tool in hydrological model calibration. They provide the hydrologist with important information on whether model calibration is susceptible to a small number of highly influent data points. This enables the hydrologist to make a more informed decision of whether to (1) remove/retain the calibration data; (2) adjust the calibration strategy and/or hydrological model to reduce the susceptibility of model predictions to a small number of influential observations.
NASA Astrophysics Data System (ADS)
Chetan; Narasimhulu, A.; Ghosh, S.; Rao, P. V.
2015-07-01
Machinability of titanium is poor due to its low thermal conductivity and high chemical affinity. Lower thermal conductivity of titanium alloy is undesirable on the part of cutting tool causing extensive tool wear. The main task of this work is to predict the various wear mechanisms involved during machining of Ti alloy (Ti6Al4V) and to formulate an analytical mathematical tool wear model for the same. It has been found from various experiments that adhesive and diffusion wear are the dominating wear during machining of Ti alloy with PVD coated tungsten carbide tool. It is also clear from the experiments that the tool wear increases with the increase in cutting parameters like speed, feed and depth of cut. The wear model was validated by carrying out dry machining of Ti alloy at suitable cutting conditions. It has been found that the wear model is able to predict the flank wear suitably under gentle cutting conditions.
An Efficient Reachability Analysis Algorithm
NASA Technical Reports Server (NTRS)
Vatan, Farrokh; Fijany, Amir
2008-01-01
A document discusses a new algorithm for generating higher-order dependencies for diagnostic and sensor placement analysis when a system is described with a causal modeling framework. This innovation will be used in diagnostic and sensor optimization and analysis tools. Fault detection, diagnosis, and prognosis are essential tasks in the operation of autonomous spacecraft, instruments, and in-situ platforms. This algorithm will serve as a power tool for technologies that satisfy a key requirement of autonomous spacecraft, including science instruments and in-situ missions.
Dutta, Dipankar
2016-02-09
The diagnosis of Transient Ischaemic Attack (TIA) can be difficult and 50-60% of patients seen in TIA clinics turn out to be mimics. Many of these mimics have high ABCD2 scores and fill urgent TIA clinic slots inappropriately. A TIA diagnostic tool may help non-specialists make the diagnosis with greater accuracy and improve TIA clinic triage. The only available diagnostic score (Dawson et al) is limited in scope and not widely used. The Diagnosis of TIA (DOT) Score is a new and internally validated web and mobile app based diagnostic tool which encompasses both brain and retinal TIA. The score was derived retrospectively from a single centre TIA clinic database using stepwise logistic regression by backwards elimination to find the best model. An optimum cutpoint was obtained for the score. The derivation and validation cohorts were separate samples drawn from the years 2010/12 and 2013 respectively. Receiver Operating Characteristic (ROC) curves and area under the curve (AUC) were calculated and the diagnostic accuracy of DOT was compared to the Dawson score. A web and smartphone calculator were designed subsequently. The derivation cohort had 879 patients and the validation cohort 525. The final model had seventeen predictors and had an AUC of 0.91 (95% CI: 0.89-0.93). When tested on the validation cohort, the AUC for DOTS was 0.89 (0.86-0.92) while that of the Dawson score was 0.77 (0.73-0.81). The sensitivity and specificity of the DOT score were 89% (CI: 84%-93%) and 76% (70%-81%) respectively while those of the Dawson score were 83% (78%-88%) and 51% (45%-57%). Other diagnostic accuracy measures (DOT vs. Dawson) include positive predictive values (75% vs. 58%), negative predictive values (89% vs. 79%), positive likelihood ratios (3.67 vs. 1.70) and negative likelihood ratios (0.15 vs. 0.32). The DOT score shows promise as a diagnostic tool for TIA and requires independent external validation before it can be widely used. It could potentially improve the triage of patients assessed for suspected TIA.
Yavarna, Tarunashree; Al-Dewik, Nader; Al-Mureikhi, Mariam; Ali, Rehab; Al-Mesaifri, Fatma; Mahmoud, Laila; Shahbeck, Noora; Lakhani, Shenela; AlMulla, Mariam; Nawaz, Zafar; Vitazka, Patrik; Alkuraya, Fowzan S; Ben-Omran, Tawfeg
2015-09-01
Clinical exome sequencing (CES) has become an increasingly popular diagnostic tool in patients with heterogeneous genetic disorders, especially in those with neurocognitive phenotypes. Utility of CES in consanguineous populations has not yet been determined on a large scale. A clinical cohort of 149 probands from Qatar with suspected Mendelian, mainly neurocognitive phenotypes, underwent CES from July 2012 to June 2014. Intellectual disability and global developmental delay were the most common clinical presentations but our cohort displayed other phenotypes, such as epilepsy, dysmorphism, microcephaly and other structural brain anomalies and autism. A pathogenic or likely pathogenic mutation, including pathogenic CNVs, was identified in 89 probands for a diagnostic yield of 60%. Consanguinity and positive family history predicted a higher diagnostic yield. In 5% (7/149) of cases, CES implicated novel candidate disease genes (MANF, GJA9, GLG1, COL15A1, SLC35F5, MAGE4, NEUROG1). CES uncovered two coexisting genetic disorders in 4% (6/149) and actionable incidental findings in 2% (3/149) of cases. Average time to diagnosis was reduced from 27 to 5 months. CES, which already has the highest diagnostic yield among all available diagnostic tools in the setting of Mendelian disorders, appears to be particularly helpful diagnostically in the highly consanguineous Middle Eastern population.
NASA Technical Reports Server (NTRS)
Oreilly, Daniel; Williams, Robert; Yarborough, Kevin
1988-01-01
This is a tutorial/diagnostic system for training personnel in the use of the Space Shuttle Main Engine Controller (SSMEC) Simulation Lab. It also provides a diagnostic capable of isolating lab failures at least to the major lab component. The system was implemented using Hypercard, which is an program of hypermedia running on Apple Macintosh computers. Hypercard proved to be a viable platform for the development and use of sophisticated tutorial systems and moderately capable diagnostic systems. This tutorial/diagnostic system uses the basic Hypercard tools to provide the tutorial. The diagnostic part of the system uses a simple interpreter written in the Hypercard language (Hypertalk) to implement the backward chaining rule based logic commonly found in diagnostic systems using Prolog. Some of the advantages of Hypercard in developing this type of system include sophisticated graphics, animation, sound and voice capabilities, its ability as a hypermedia tool, and its ability to include digitized pictures. The major disadvantage is the slow execution time for evaluation of rules (due to the interpretive processing of the language). Other disadvantages include the limitation on the size of the cards, that color is not supported, that it does not support grey scale graphics, and its lack of selectable fonts for text fields.
Tuberculosis Diagnostics in 2015: Landscape, Priorities, Needs, and Prospects
Pai, Madhukar; Schito, Marco
2015-01-01
In 2015, tuberculosis remains a major global health problem, and drug-resistant tuberculosis is a growing threat. Although tuberculosis diagnosis in many countries is still reliant on older tools, new diagnostics are changing the landscape. Stimulated, in part, by the success and roll out of Xpert MTB/RIF, there is now considerable interest in new technologies. The landscape looks promising, with a robust pipeline of new tools, particularly molecular diagnostics, and well over 50 companies actively engaged in product development. However, new diagnostics are yet to reach scale, and there needs to be greater convergence between diagnostics development and development of shorter-duration tuberculosis drug regimens. Another concern is the relative absence of non–sputum-based diagnostics in the pipeline for children and of biomarker tests for triage, cure, and progression of latent Mycobacterium tuberculosis infection. Several initiatives, described in this supplement, have been launched to further stimulate product development and policy, including assessment of needs and priorities, development of target product profiles, compilation of data on resistance-associated mutations, and assessment of market size and potential for new diagnostics. Advocacy is needed to increase funding for tuberculosis research and development, and governments in high-burden countries must invest more in tuberculosis control to meet post-2015 targets for care, control, and prevention. PMID:25765103
Developments in label-free microfluidic methods for single-cell analysis and sorting.
Carey, Thomas R; Cotner, Kristen L; Li, Brian; Sohn, Lydia L
2018-04-24
Advancements in microfluidic technologies have led to the development of many new tools for both the characterization and sorting of single cells without the need for exogenous labels. Label-free microfluidics reduce the preparation time, reagents needed, and cost of conventional methods based on fluorescent or magnetic labels. Furthermore, these devices enable analysis of cell properties such as mechanical phenotype and dielectric parameters that cannot be characterized with traditional labels. Some of the most promising technologies for current and future development toward label-free, single-cell analysis and sorting include electronic sensors such as Coulter counters and electrical impedance cytometry; deformation analysis using optical traps and deformation cytometry; hydrodynamic sorting such as deterministic lateral displacement, inertial focusing, and microvortex trapping; and acoustic sorting using traveling or standing surface acoustic waves. These label-free microfluidic methods have been used to screen, sort, and analyze cells for a wide range of biomedical and clinical applications, including cell cycle monitoring, rapid complete blood counts, cancer diagnosis, metastatic progression monitoring, HIV and parasite detection, circulating tumor cell isolation, and point-of-care diagnostics. Because of the versatility of label-free methods for characterization and sorting, the low-cost nature of microfluidics, and the rapid prototyping capabilities of modern microfabrication, we expect this class of technology to continue to be an area of high research interest going forward. New developments in this field will contribute to the ongoing paradigm shift in cell analysis and sorting technologies toward label-free microfluidic devices, enabling new capabilities in biomedical research tools as well as clinical diagnostics. This article is categorized under: Diagnostic Tools > Biosensing Diagnostic Tools > Diagnostic Nanodevices. © 2018 Wiley Periodicals, Inc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Imrisek, M.; Faculty of Mathematics and Physics, Charles University in Prague, Prague; Weinzettl, V.
2014-11-15
The soft x-ray diagnostic is suitable for monitoring plasma activity in the tokamak core, e.g., sawtooth instability. Moreover, spatially resolved measurements can provide information about plasma position and shape, which can supplement magnetic measurements. In this contribution, fast algorithms with the potential for a real-time use are tested on the data from the COMPASS tokamak. In addition, the soft x-ray data are compared with data from other diagnostics in order to discuss possible connection between sawtooth instability on one side and the transition to higher confinement mode, edge localized modes and productions of runaway electrons on the other side.
Mendoza, Maria C.B.; Burns, Trudy L.; Jones, Michael P.
2009-01-01
Objectives Case-deletion diagnostic methods are tools that allow identification of influential observations that may affect parameter estimates and model fitting conclusions. The goal of this paper was to develop two case-deletion diagnostics, the exact case deletion (ECD) and the empirical influence function (EIF), for detecting outliers that can affect results of sib-pair maximum likelihood quantitative trait locus (QTL) linkage analysis. Methods Subroutines to compute the ECD and EIF were incorporated into the maximum likelihood QTL variance estimation components of the linkage analysis program MAPMAKER/SIBS. Performance of the diagnostics was compared in simulation studies that evaluated the proportion of outliers correctly identified (sensitivity), and the proportion of non-outliers correctly identified (specificity). Results Simulations involving nuclear family data sets with one outlier showed EIF sensitivities approximated ECD sensitivities well for outlier-affected parameters. Sensitivities were high, indicating the outlier was identified a high proportion of the time. Simulations also showed the enormous computational time advantage of the EIF. Diagnostics applied to body mass index in nuclear families detected observations influential on the lod score and model parameter estimates. Conclusions The EIF is a practical diagnostic tool that has the advantages of high sensitivity and quick computation. PMID:19172086
Script-theory virtual case: A novel tool for education and research.
Hayward, Jake; Cheung, Amandy; Velji, Alkarim; Altarejos, Jenny; Gill, Peter; Scarfe, Andrew; Lewis, Melanie
2016-11-01
Context/Setting: The script theory of diagnostic reasoning proposes that clinicians evaluate cases in the context of an "illness script," iteratively testing internal hypotheses against new information eventually reaching a diagnosis. We present a novel tool for teaching diagnostic reasoning to undergraduate medical students based on an adaptation of script theory. We developed a virtual patient case that used clinically authentic audio and video, interactive three-dimensional (3D) body images, and a simulated electronic medical record. Next, we used interactive slide bars to record respondents' likelihood estimates of diagnostic possibilities at various stages of the case. Responses were dynamically compared to data from expert clinicians and peers. Comparative frequency distributions were presented to the learner and final diagnostic likelihood estimates were analyzed. Detailed student feedback was collected. Over two academic years, 322 students participated. Student diagnostic likelihood estimates were similar year to year, but were consistently different from expert clinician estimates. Student feedback was overwhelmingly positive: students found the case was novel, innovative, clinically authentic, and a valuable learning experience. We demonstrate the successful implementation of a novel approach to teaching diagnostic reasoning. Future study may delineate reasoning processes associated with differences between novice and expert responses.
Smith, Hadley Stevens; Swint, J Michael; Lalani, Seema R; Yamal, Jose-Miguel; de Oliveira Otto, Marcia C; Castellanos, Stephan; Taylor, Amy; Lee, Brendan H; Russell, Heidi V
2018-05-14
Availability of clinical genomic sequencing (CGS) has generated questions about the value of genome and exome sequencing as a diagnostic tool. Analysis of reported CGS application can inform uptake and direct further research. This scoping literature review aims to synthesize evidence on the clinical and economic impact of CGS. PubMed, Embase, and Cochrane were searched for peer-reviewed articles published between 2009 and 2017 on diagnostic CGS for infant and pediatric patients. Articles were classified according to sample size and whether economic evaluation was a primary research objective. Data on patient characteristics, clinical setting, and outcomes were extracted and narratively synthesized. Of 171 included articles, 131 were case reports, 40 were aggregate analyses, and 4 had a primary economic evaluation aim. Diagnostic yield was the only consistently reported outcome. Median diagnostic yield in aggregate analyses was 33.2% but varied by broad clinical categories and test type. Reported CGS use has rapidly increased and spans diverse clinical settings and patient phenotypes. Economic evaluations support the cost-saving potential of diagnostic CGS. Multidisciplinary implementation research, including more robust outcome measurement and economic evaluation, is needed to demonstrate clinical utility and cost-effectiveness of CGS.
[Current macro-diagnostic trends of forensic medicine in the Czech Republic].
Frišhons, Jan; Kučerová, Štěpánka; Jurda, Mikoláš; Sokol, Miloš; Vojtíšek, Tomáš; Hejna, Petr
2017-01-01
Over the last few years, advanced diagnostic methods have penetrated in the realm of forensic medicine in addition to standard autopsy techniques supported by traditional X-ray examination and macro-diagnostic laboratory tests. Despite the progress of imaging methods, the conventional autopsy has remained basic and essential diagnostic tool in forensic medicine. Postmortem computed tomography and magnetic resonance imaging are far the most progressive modern radio diagnostic methods setting the current trend of virtual autopsies all over the world. Up to now, only two institutes of forensic medicine have available postmortem computed tomography for routine diagnostic purposes in the Czech Republic. Postmortem magnetic resonance is currently unattainable for routine diagnostic use and was employed only for experimental purposes. Photogrammetry is digital method focused primarily on body surface imaging. Recently, the most fruitful results have been yielded from the interdisciplinary cooperation between forensic medicine and forensic anthropology with the implementation of body scanning techniques and 3D printing. Non-invasive and mini-invasive investigative methods such as postmortem sonography and postmortem endoscopy was unsystematically tested for diagnostic performance with good outcomes despite of limitations of these methods in postmortem application. Other futuristic methods, such as the use of a drone to inspect the crime scene are still experimental tools. The authors of the article present a basic overview of the both routinely and experimentally used investigative methods and current macro-diagnostic trends of the forensic medicine in the Czech Republic.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Han, S; Ji, Y; Kim, K
Purpose: A diagnostics Multileaf Collimator (MLC) was designed for diagnostic radiography dose reduction. Monte Carlo simulation was used to evaluate efficiency of shielding material for producing leaves of Multileaf collimator. Material & Methods: The general radiography unit (Rex-650R, Listem, Korea) was modeling with Monte Carlo simulation (MCNPX, LANL, USA) and we used SRS-78 program to calculate the energy spectrum of tube voltage (80, 100, 120 kVp). The shielding materials was SKD 11 alloy tool steel that is composed of 1.6% carbon(C), 0.4% silicon (Si), 0.6% manganese (Mn), 5% chromium (Cr), 1% molybdenum (Mo), and vanadium (V). The density of itmore » was 7.89 g/m3. We simulated leafs diagnostic MLC using SKD 11 with general radiography unit. We calculated efficiency of diagnostic MLC using tally6 card of MCNPX depending on energy. Results: The diagnostic MLC consisted of 25 individual metal shielding leaves on both sides, with dimensions of 10 × 0.5 × 0.5 cm3. The leaves of MLC were controlled by motors positioned on both sides of the MLC. According to energy (tube voltage), the shielding efficiency of MLC in Monte Carlo simulation was 99% (80 kVp), 96% (100 kVp) and 93% (120 kVp). Conclusion: We certified efficiency of diagnostic MLC fabricated from SKD11 alloy tool steel. Based on the results, the diagnostic MLC was designed. We will make the diagnostic MLC for dose reduction of diagnostic radiography.« less
Mitchell, Alex J; Smith, Adam B; Al-salihy, Zerak; Rahim, Twana A; Mahmud, Mahmud Q; Muhyaldin, Asma S
2011-10-01
We aimed to redefine the optimal self-report symptoms of depression suitable for creation of an item bank that could be used in computer adaptive testing or to develop a simplified screening tool for DSM-V. Four hundred subjects (200 patients with primary depression and 200 non-depressed subjects), living in Iraqi Kurdistan were interviewed. The Mini International Neuropsychiatric Interview (MINI) was used to define the presence of major depression (DSM-IV criteria). We examined symptoms of depression using four well-known scales delivered in Kurdish. The Partial Credit Model was applied to each instrument. Common-item equating was subsequently used to create an item bank and differential item functioning (DIF) explored for known subgroups. A symptom level Rasch analysis reduced the original 45 items to 24 items of the original after the exclusion of 21 misfitting items. A further six items (CESD13 and CESD17, HADS-D4, HADS-D5 and HADS-D7, and CDSS3 and CDSS4) were removed due to misfit as the items were added together to form the item bank, and two items were subsequently removed following the DIF analysis by diagnosis (CESD20 and CDSS9, both of which were harder to endorse for women). Therefore the remaining optimal item bank consisted of 17 items and produced an area under the curve (AUC) of 0.987. Using a bank restricted to the optimal nine items revealed only minor loss of accuracy (AUC = 0.989, sensitivity 96%, specificity 95%). Finally, when restricted to only four items accuracy was still high (AUC was still 0.976; sensitivity 93%, specificity 96%). An item bank of 17 items may be useful in computer adaptive testing and nine or even four items may be used to develop a simplified screening tool for DSM-V major depressive disorder (MDD). Further examination of this item bank should be conducted in different cultural settings.
High-resolution Antibody Array Analysis of Childhood Acute Leukemia Cells*
Kanderova, Veronika; Kuzilkova, Daniela; Stuchly, Jan; Vaskova, Martina; Brdicka, Tomas; Fiser, Karel; Hrusak, Ondrej; Lund-Johansen, Fridtjof
2016-01-01
Acute leukemia is a disease pathologically manifested at both genomic and proteomic levels. Molecular genetic technologies are currently widely used in clinical research. In contrast, sensitive and high-throughput proteomic techniques for performing protein analyses in patient samples are still lacking. Here, we used a technology based on size exclusion chromatography followed by immunoprecipitation of target proteins with an antibody bead array (Size Exclusion Chromatography-Microsphere-based Affinity Proteomics, SEC-MAP) to detect hundreds of proteins from a single sample. In addition, we developed semi-automatic bioinformatics tools to adapt this technology for high-content proteomic screening of pediatric acute leukemia patients. To confirm the utility of SEC-MAP in leukemia immunophenotyping, we tested 31 leukemia diagnostic markers in parallel by SEC-MAP and flow cytometry. We identified 28 antibodies suitable for both techniques. Eighteen of them provided excellent quantitative correlation between SEC-MAP and flow cytometry (p < 0.05). Next, SEC-MAP was applied to examine 57 diagnostic samples from patients with acute leukemia. In this assay, we used 632 different antibodies and detected 501 targets. Of those, 47 targets were differentially expressed between at least two of the three acute leukemia subgroups. The CD markers correlated with immunophenotypic categories as expected. From non-CD markers, we found DBN1, PAX5, or PTK2 overexpressed in B-cell precursor acute lymphoblastic leukemias, LAT, SH2D1A, or STAT5A overexpressed in T-cell acute lymphoblastic leukemias, and HCK, GLUD1, or SYK overexpressed in acute myeloid leukemias. In addition, OPAL1 overexpression corresponded to ETV6-RUNX1 chromosomal translocation. In summary, we demonstrated that SEC-MAP technology is a powerful tool for detecting hundreds of proteins in clinical samples obtained from pediatric acute leukemia patients. It provides information about protein size and reveals differences in protein expression between particular leukemia subgroups. Forty-seven of SEC-MAP identified targets were validated by other conventional method in this study. PMID:26785729
Rural People with Disabilities
... Toolkits Economic Impact Analysis Tool Community Health Gateway Sustainability Planning Tools Testing New Approaches Rural Health IT ... problems Accessible treatment and diagnostic equipment A 2017 report from the Centers for Medicare and Medicaid Services ( ...
Genomics-enabled sensor platform for rapid detection of viruses related to disease outbreak.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brozik, Susan M; Manginell, Ronald P; Moorman, Matthew W
2013-09-01
Bioweapons and emerging infectious diseases pose growing threats to our national security. Both natural disease outbreak and outbreaks due to a bioterrorist attack are a challenge to detect, taking days after the outbreak to identify since most outbreaks are only recognized through reportable diseases by health departments and reports of unusual diseases by clinicians. In recent decades, arthropod-borne viruses (arboviruses) have emerged as some of the most significant threats to human health. They emerge, often unexpectedly, from cryptic transmission foci causing localized outbreaks that can rapidly spread to multiple continents due to increased human travel and trade. Currently, diagnosis ofmore » acute infections requires amplification of viral nucleic acids, which can be costly, highly specific, technically challenging and time consuming. No diagnostic devices suitable for use at the bedside or in an outbreak setting currently exist. The original goals of this project were to 1) develop two highly sensitive and specific diagnostic assays for detecting RNA from a wide range of arboviruses; one based on an electrochemical approach and the other a fluorescent based assay and 2) develop prototype microfluidic diagnostic platforms for preclinical and field testing that utilize the assays developed in goal 1. We generated and characterized suitable primers for West Nile Virus RNA detection. Both optical and electrochemical transduction technologies were developed for DNA-RNA hybridization detection and were implemented in microfluidic diagnostic sensing platforms that were developed in this project.« less
[Clinical Application of Non-invasive Diagnostic Tests for Liver Fibrosis].
Shin, Jung Woo; Park, Neung Hwa
2016-07-25
The diagnostic assessment of liver fibrosis is an important step in the management of patients with chronic liver diseases. Liver biopsy is considered the gold standard to assess necroinflammation and fibrosis. However, recent technical advances have introduced numerous serum biomarkers and imaging tools using elastography as noninvasive alternatives to biopsy. Serum markers can be direct or indirect markers of the fibrosis process. The elastography-based studies include transient elastography, acoustic radiation force imaging, supersonic shear wave imaging and magnetic resonance elastography. As accumulation of clinical data shows that noninvasive tests provide prognostic information of clinical relevance, non-invasive diagnostic tools have been incorporated into clinical guidelines and practice. Here, the authors review noninvasive tests for the diagnosis of liver fibrosis.
Analytical considerations for mass spectrometry profiling in serum biomarker discovery.
Whiteley, Gordon R; Colantonio, Simona; Sacconi, Andrea; Saul, Richard G
2009-03-01
The potential of using mass spectrometry profiling as a diagnostic tool has been demonstrated for a wide variety of diseases. Various cancers and cancer-related diseases have been the focus of much of this work because of both the paucity of good diagnostic markers and the knowledge that early diagnosis is the most powerful weapon in treating cancer. The implementation of mass spectrometry as a routine diagnostic tool has proved to be difficult, however, primarily because of the stringent controls that are required for the method to be reproducible. The method is evolving as a powerful guide to the discovery of biomarkers that could, in turn, be used either individually or in an array or panel of tests for early disease detection. Using proteomic patterns to guide biomarker discovery and the possibility of deployment in the clinical laboratory environment on current instrumentation or in a hybrid technology has the possibility of being the early diagnosis tool that is needed.
Kaur, Navaldeep; Belchior, Patricia; Gelinas, Isabelle; Bier, Nathalie
2016-09-01
Mild deficits in instrumental activities of daily living (IADLs) have consistently been reported in the individuals with mild cognitive impairment (MCI). A variety of functional assessment tools, including self-and informant report questionnaires and performance-based measures, have been employed in MCI. Previously, a limited focus has been directed at appraising the quality of questionnaires. The goal of this study was to identify the questionnaires that have been validated in the MCI population. Additionally, the quality of validation studies and psychometric attributes of these questionnaires were appraised. Relevant articles were systematically searched in PsychINFO, Ovid MEDLINE, and CINAHL against specific eligibility criteria. To evaluate the methodology of the psychometric studies, the COSMIN checklist was employed. Also, the psychometric properties of the assessment tools were evaluated based upon Terwee's criteria. A total of five psychometric studies and questionnaires were critically evaluated. Varying psychometric properties were available for the chosen tools. None of the studies received the best possible rating for their methodological quality. It was found that questionnaires with high discriminative ability to distinguish MCI from other diagnostic groups were: Disability Assessment in Dementia-6 (DAD-6), Functional Activity Questionnaire (FAQ), and Alzheimer's Disease Cooperative Study/Activities of Daily Living scale adapted for MCI patients (ADCS-MCI-ADL-24). Psychometric studies with strong methodological rigor are required in the future. Considering the fact that IADL decline has been associated with dementia, early detection of functional difficulties in MCI needs to be encouraged as it will allow suitable and timely interventions to prolong functional independence of affected individuals.
NASA Astrophysics Data System (ADS)
Mehta, Neville; Kompalli, Suryaprakash; Chaudhary, Vipin
Teleradiology is the electronic transmission of radiological patient images, such as x-rays, CT, or MR across multiple locations. The goal could be interpretation, consultation, or medical records keeping. Information technology solutions have enabled electronic records and their associated benefits are evident in health care today. However, salient aspects of collaborative interfaces, and computer assisted diagnostic (CAD) tools are yet to be integrated into workflow designs. The Computer Assisted Diagnostics and Interventions (CADI) group at the University at Buffalo has developed an architecture that facilitates web-enabled use of CAD tools, along with the novel concept of synchronized collaboration. The architecture can support multiple teleradiology applications and case studies are presented here.
To Duc, Khanh
2017-11-18
Receiver operating characteristic (ROC) surface analysis is usually employed to assess the accuracy of a medical diagnostic test when there are three ordered disease status (e.g. non-diseased, intermediate, diseased). In practice, verification bias can occur due to missingness of the true disease status and can lead to a distorted conclusion on diagnostic accuracy. In such situations, bias-corrected inference tools are required. This paper introduce an R package, named bcROCsurface, which provides utility functions for verification bias-corrected ROC surface analysis. The shiny web application of the correction for verification bias in estimation of the ROC surface analysis is also developed. bcROCsurface may become an important tool for the statistical evaluation of three-class diagnostic markers in presence of verification bias. The R package, readme and example data are available on CRAN. The web interface enables users less familiar with R to evaluate the accuracy of diagnostic tests, and can be found at http://khanhtoduc.shinyapps.io/bcROCsurface_shiny/ .
Diagnosing schistosomiasis: where are we?
Gomes, Luciana Inácia; Enk, Martin Johannes; Rabello, Ana
2014-01-01
In light of the World Health Organization's initiative to extend schistosomiasis morbidity and mortality control programs by including a disease elimination strategy in low endemic settings, this paper reviews diagnostic tools described during the last decades and provide an overview of ongoing efforts in making an efficient diagnostic tool available worldwide. A literature search on PubMed using the search criteria schistosomiasis and diagnosis within the period from 1978 to 2013 was carried out. Articles with abstract in English and that used laboratory techniques specifically developed for the detection of schistosomiasis in humans were included. Publications were categorized according to the methodology applied (parasitological, immunological, or molecular) and stage of development (in house development, limited field, or large scale field testing). The initial research generated 4,535 publications, of which only 643 met the inclusion criteria. The vast majority (537) of the publications focused on immunological techniques; 81 focused on parasitological diagnosis, and 25 focused on molecular diagnostic methods. Regarding the stage of development, 307 papers referred to in-house development, 202 referred to limited field tests, and 134 referred to large scale field testing. The data obtained show that promising new diagnostic tools, especially for Schistosoma antigen and deoxyribonucleic acid (DNA) detection, which are characterized by high sensitivity and specificity, are being developed. In combination with international funding initiatives these tools may result in a significant step forward in successful disease elimination and surveillance, which is to make efficient tests accessible and its large use self-sustainable for control programs in endemic countries.
ERIC Educational Resources Information Center
Seligman, Linda; Moore, Bonita Marcus
1995-01-01
Provides an overview of mood disorders according to Diagnostic and Statistical Manual (fourth edition) criteria and other relevant information. Differential diagnosis is facilitated through discussion of differences and similarities among mental disorders, age and gender-related patterns of mood disorders, and useful diagnostic tools. (Author)
Hofmann, Natalie; Mwingira, Felista; Shekalaghe, Seif; Robinson, Leanne J.; Mueller, Ivo; Felger, Ingrid
2015-01-01
Background Planning and evaluating malaria control strategies relies on accurate definition of parasite prevalence in the population. A large proportion of asymptomatic parasite infections can only be identified by surveillance with molecular methods, yet these infections also contribute to onward transmission to mosquitoes. The sensitivity of molecular detection by PCR is limited by the abundance of the target sequence in a DNA sample; thus, detection becomes imperfect at low densities. We aimed to increase PCR diagnostic sensitivity by targeting multi-copy genomic sequences for reliable detection of low-density infections, and investigated the impact of these PCR assays on community prevalence data. Methods and Findings Two quantitative PCR (qPCR) assays were developed for ultra-sensitive detection of Plasmodium falciparum, targeting the high-copy telomere-associated repetitive element 2 (TARE-2, ∼250 copies/genome) and the var gene acidic terminal sequence (varATS, 59 copies/genome). Our assays reached a limit of detection of 0.03 to 0.15 parasites/μl blood and were 10× more sensitive than standard 18S rRNA qPCR. In a population cross-sectional study in Tanzania, 295/498 samples tested positive using ultra-sensitive assays. Light microscopy missed 169 infections (57%). 18S rRNA qPCR failed to identify 48 infections (16%), of which 40% carried gametocytes detected by pfs25 quantitative reverse-transcription PCR. To judge the suitability of the TARE-2 and varATS assays for high-throughput screens, their performance was tested on sample pools. Both ultra-sensitive assays correctly detected all pools containing one low-density P. falciparum–positive sample, which went undetected by 18S rRNA qPCR, among nine negatives. TARE-2 and varATS qPCRs improve estimates of prevalence rates, yet other infections might still remain undetected when absent in the limited blood volume sampled. Conclusions Measured malaria prevalence in communities is largely determined by the sensitivity of the diagnostic tool used. Even when applying standard molecular diagnostics, prevalence in our study population was underestimated by 8% compared to the new assays. Our findings highlight the need for highly sensitive tools such as TARE-2 and varATS qPCR in community surveillance and for monitoring interventions to better describe malaria epidemiology and inform malaria elimination efforts. PMID:25734259
Hawkins, Kenneth R; Cantera, Jason L; Storey, Helen L; Leader, Brandon T; de Los Santos, Tala
2016-12-01
Global efforts to address schistosomiasis and soil-transmitted helminthiases (STH) include deworming programs for school-aged children that are made possible by large-scale drug donations. Decisions on these mass drug administration (MDA) programs currently rely on microscopic examination of clinical specimens to determine the presence of parasite eggs. However, microscopy-based methods are not sensitive to the low-intensity infections that characterize populations that have undergone MDA. Thus, there has been increasing recognition within the schistosomiasis and STH communities of the need for improved diagnostic tools to support late-stage control program decisions, such as when to stop or reduce MDA. Failure to adequately address the need for new diagnostics could jeopardize achievement of the 2020 London Declaration goals. In this report, we assess diagnostic needs and landscape potential solutions and determine appropriate strategies to improve diagnostic testing to support control and elimination programs. Based upon literature reviews and previous input from experts in the schistosomiasis and STH communities, we prioritized two diagnostic use cases for further exploration: to inform MDA-stopping decisions and post-MDA surveillance. To this end, PATH has refined target product profiles (TPPs) for schistosomiasis and STH diagnostics that are applicable to these use cases. We evaluated the limitations of current diagnostic methods with regards to these use cases and identified candidate biomarkers and diagnostics with potential application as new tools. Based on this analysis, there is a need to develop antigen-detecting rapid diagnostic tests (RDTs) with simplified, field-deployable sample preparation for schistosomiasis. Additionally, there is a need for diagnostic tests that are more sensitive than the current methods for STH, which may include either a field-deployable molecular test or a simple, low-cost, rapid antigen-detecting test.
Ceramic-bonded abrasive grinding tools
Holcombe, C.E. Jr.; Gorin, A.H.; Seals, R.D.
1994-11-22
Abrasive grains such as boron carbide, silicon carbide, alumina, diamond, cubic boron nitride, and mullite are combined with a cement primarily comprised of zinc oxide and a reactive liquid setting agent and solidified into abrasive grinding tools. Such grinding tools are particularly suitable for grinding and polishing stone, such as marble and granite.
Ceramic-bonded abrasive grinding tools
Holcombe, Jr., Cressie E.; Gorin, Andrew H.; Seals, Roland D.
1994-01-01
Abrasive grains such as boron carbide, silicon carbide, alumina, diamond, cubic boron nitride, and mullite are combined with a cement primarily comprised of zinc oxide and a reactive liquid setting agent and solidified into abrasive grinding tools. Such grinding tools are particularly suitable for grinding and polishing stone, such as marble and granite.
Benefit-risk Evaluation for Diagnostics: A Framework (BED-FRAME).
Evans, Scott R; Pennello, Gene; Pantoja-Galicia, Norberto; Jiang, Hongyu; Hujer, Andrea M; Hujer, Kristine M; Manca, Claudia; Hill, Carol; Jacobs, Michael R; Chen, Liang; Patel, Robin; Kreiswirth, Barry N; Bonomo, Robert A
2016-09-15
The medical community needs systematic and pragmatic approaches for evaluating the benefit-risk trade-offs of diagnostics that assist in medical decision making. Benefit-Risk Evaluation of Diagnostics: A Framework (BED-FRAME) is a strategy for pragmatic evaluation of diagnostics designed to supplement traditional approaches. BED-FRAME evaluates diagnostic yield and addresses 2 key issues: (1) that diagnostic yield depends on prevalence, and (2) that different diagnostic errors carry different clinical consequences. As such, evaluating and comparing diagnostics depends on prevalence and the relative importance of potential errors. BED-FRAME provides a tool for communicating the expected clinical impact of diagnostic application and the expected trade-offs of diagnostic alternatives. BED-FRAME is a useful fundamental supplement to the standard analysis of diagnostic studies that will aid in clinical decision making. © The Author 2016. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail journals.permissions@oup.com.
Wide, Leif
2005-01-01
The universities are encouraged by the government nowadays to stimulate innovations and also to provide the proper machinery for assisting the protection and commercialisation of innovations. A better understanding of the innovation process may help to create an atmosphere suitable for inventions at the university. Examples can be taken from successful innovations previously made at the university. During the 1960's I made a series of inventions, which ultimately led to the development of the diagnostic test kit industry. The first, which I made as an undergraduate, was a simple and reliable test kit for diagnosis of pregnancy. This was followed by the solid phase radioimmunoassay and a solid phase assay for vitamin B12; next, the dual specific non-competitive sandwich assay and the in-vitro test for diagnosis of allergy, called RAST (Radioallergosorbent test). Organon in Holland with the pregnancy test kit, and Pharmacia in Sweden with test kits for radioimmunoassay, became pioneers among the diagnostic test kit industries. Pharmacia Diagnostics later became one of the leading diagnostic test kit companies in the world and has continued to be so in the field of allergy diagnosis. Each one of these inventions started with a few unique observations leading to a technical development. The pregnancy test as well as the allergy test emerged from the development of assay methods with unique qualities with the subsequent search for appropriate applications. The foreseeing of a commercial value on a future market was a very important step. This was followed by the search for a suitable industry interested to exploit the invention with its new business opportunity i.e. apply for a patent, produce and market the products, which in my case consisted of the necessary reagents and equipments for particular diagnostic tests. Finally, an agreement had to be settled between the entrepreneur and the inventors. This report describes these inventions and particularly discusses some crucial steps of the innovation processes.
Franceschi, Valentina; Jacca, Sarah; Sassu, Elena L.; Stellari, Fabio F.; van Santen, Vicky L.; Donofrio, Gaetano
2014-01-01
Raising of alpacas as exotic livestock for wool and meat production and as companion animals is growing in importance in the United States, Europe and Australia. Furthermore the alpaca, as well as the rest of the camelids, possesses the peculiarity of producing single-chain antibodies from which nanobodies can be generated. Nanobodies, due to their structural simplicity and reduced size, are very versatile in terms of manipulation and bio-therapeutic exploitation. In fact the biotech companies involved in nanobody production and application continue to grow in number and size. Hence, the development of reagents and tools to assist in the further growth of this new scientific and entrepreneurial reality is becoming a necessity. These are needed mainly to address alpaca disease diagnosis and prophylaxis, and to develop alpaca immunization strategies for nanobody generation. For instance an immortalized alpaca cell line would be extremely valuable. In the present work the first stabilized alpaca cell line from alpaca skin stromal cells (ASSCs) was generated and characterized. This cell line was shown to be suitable for replication of viruses bovine herpesvirus-1, bovine viral diarrhea virus and caprine herpesvirus-1 and the endocellular parasite Neospora caninum. Moreover ASSCs were easy to transfect and transduce by several methods. These two latter characteristics are extremely useful when recombinant antigens need to be produced in a host homologous system. This work could be considered as a starting point for the expansion of the biotechnologies linked to alpaca farming and industry. PMID:25140515
2017-01-01
Chemiluminescence probes are considered to be among the most sensitive diagnostic tools that provide high signal-to-noise ratio for various applications such as DNA detection and immunoassays. We have developed a new molecular methodology to design and foresee light-emission properties of turn-ON chemiluminescence dioxetane probes suitable for use under physiological conditions. The methodology is based on incorporation of a substituent on the benzoate species obtained during the chemiexcitation pathway of Schaap’s adamantylidene–dioxetane probe. The substituent effect was initially evaluated on the fluorescence emission generated by the benzoate species and then on the chemiluminescence of the dioxetane luminophores. A striking substituent effect on the chemiluminescence efficiency of the probes was obtained when acrylate and acrylonitrile electron-withdrawing groups were installed. The chemiluminescence quantum yield of the best probe was more than 3 orders of magnitude higher than that of a standard, commercially available adamantylidene–dioxetane probe. These are the most powerful chemiluminescence dioxetane probes synthesized to date that are suitable for use under aqueous conditions. One of our probes was capable of providing high-quality chemiluminescence cell images based on endogenous activity of β-galactosidase. This is the first demonstration of cell imaging achieved by a non-luciferin small-molecule probe with direct chemiluminescence mode of emission. We anticipate that the strategy presented here will lead to development of efficient chemiluminescence probes for various applications in the field of sensing and imaging. PMID:28470053
Franceschi, Valentina; Jacca, Sarah; Sassu, Elena L; Stellari, Fabio F; van Santen, Vicky L; Donofrio, Gaetano
2014-01-01
Raising of alpacas as exotic livestock for wool and meat production and as companion animals is growing in importance in the United States, Europe and Australia. Furthermore the alpaca, as well as the rest of the camelids, possesses the peculiarity of producing single-chain antibodies from which nanobodies can be generated. Nanobodies, due to their structural simplicity and reduced size, are very versatile in terms of manipulation and bio-therapeutic exploitation. In fact the biotech companies involved in nanobody production and application continue to grow in number and size. Hence, the development of reagents and tools to assist in the further growth of this new scientific and entrepreneurial reality is becoming a necessity. These are needed mainly to address alpaca disease diagnosis and prophylaxis, and to develop alpaca immunization strategies for nanobody generation. For instance an immortalized alpaca cell line would be extremely valuable. In the present work the first stabilized alpaca cell line from alpaca skin stromal cells (ASSCs) was generated and characterized. This cell line was shown to be suitable for replication of viruses bovine herpesvirus-1, bovine viral diarrhea virus and caprine herpesvirus-1 and the endocellular parasite Neospora caninum. Moreover ASSCs were easy to transfect and transduce by several methods. These two latter characteristics are extremely useful when recombinant antigens need to be produced in a host homologous system. This work could be considered as a starting point for the expansion of the biotechnologies linked to alpaca farming and industry.
[Diagnostic imaging of changes of the canine intervertebral disc].
Harder, Lisa K
2016-10-12
Intervertebral disc degeneration can cause intervertebral disc herniation. Diagnostic imaging, including radiography, computed tomography and magnetic resonance imaging, is the most important tool in diagnosis. Firstly, an overview of macroscopic and biochemical physiology and pathology of the intervertebral disc will be given. Subsequently, the physics of diagnostic imaging and the appearance of intervertebral disc degeneration and displacement in several imaging methods are described.
STS-57 Pilot Duffy uses TDS soldering tool in SPACEHAB-01 aboard OV-105
NASA Technical Reports Server (NTRS)
1993-01-01
STS-57 Pilot Brian J. Duffy, at a SPACEHAB-01 (Commercial Middeck Augmentation Module (CMAM)) work bench, handles a soldering tool onboard the Earth-orbiting Endeavour, Orbiter Vehicle (OV) 105. Duffy is conducting a soldering experiment (SE) which is part of the Tools and Diagnostic Systems (TDS) project. He is soldering on a printed circuit board, positioned in a specially designed holder, containing 45 connection points and will later de-solder 35 points on a similar board. TDS' sponsor is the Flight Crew Support Division, Space and Life Sciences Directorate, JSC. It represents a group of equipment selected from tools and diagnostic hardware to be supported by the Space Station program. TDS was designed to demonstrate the maintenance of experiment hardware on-orbit and to evaluate the adequacy of its design and the crew interface.
Saliva diagnostics – Current views and directions
Kaczor-Urbanowicz, Karolina Elżbieta; Martin Carreras-Presas, Carmen; Aro, Katri; Tu, Michael; Wong, David TW
2016-01-01
In this review, we provide an update on the current and future applications of saliva for diagnostic purposes. There are many advantages of using saliva as a biofluid. Its collection is fast, easy, inexpensive, and non-invasive. In addition, saliva, as a “mirror of the body,” can reflect the physiological and pathological state of the body. Therefore, it serves as a diagnostic and monitoring tool in many fields of science such as medicine, dentistry, and pharmacotherapy. Introduced in 2008, the term “Salivaomics” aimed to highlight the rapid development of knowledge about various “omics” constituents of saliva, including: proteome, transcriptome, micro-RNA, metabolome, and microbiome. In the last few years, researchers have developed new technologies and validated a wide range of salivary biomarkers that will soon make the use of saliva a clinical reality. However, a great need still exists for convenient and accurate point-of-care devices that can serve as a non-invasive diagnostic tool. In addition, there is an urgent need to decipher the scientific rationale and mechanisms that convey systemic diseases to saliva. Another promising technology called liquid biopsy enables detection of circulating tumor cells (CTCs) and fragments of tumor DNA in saliva, thus enabling non-invasive early detection of various cancers. The newly developed technology—electric field-induced release and measurement (EFIRM) provides near perfect detection of actionable mutations in lung cancer patients. These recent advances widened the salivary diagnostic approach from the oral cavity to the whole physiological system, and thus point towards a promising future of salivary diagnostics for personalized individual medicine applications including clinical decisions and post-treatment outcome predictions. Impact statement The purpose of this mini-review is to make an update about the present and future applications of saliva as a diagnostic biofluid in many fields of science such as dentistry, medicine and pharmacotherapy. Using saliva as a fluid for diagnostic purposes would be a huge breakthrough for both patients and healthcare providers since saliva collection is easy, non-invasive and inexpensive. We will go through the current main diagnostic applications of saliva, and provide a highlight on the emerging, newly developing technologies and tools for cancer screening, detection and monitoring. PMID:27903834
Anticona Huaynate, Cynthia Fiorella; Pajuelo Travezaño, Monica Jehnny; Correa, Malena; Mayta Malpartida, Holger; Oberhelman, Richard; Murphy, Laura L; Paz-Soldan, Valerie A
2015-10-05
Worldwide, rural communities face barriers when accessing health services. In response, numerous initiatives have focused on fostering technological innovations, new management approaches and health policies. Research suggests that the most successful innovations are those involving stakeholders at all levels. However, there is little evidence exploring the opinions of local health providers that could contribute with further innovation development and research. The aims of this study were to explore the perspectives of medical doctors (MDs) working in rural areas of Peru, regarding the barriers impacting the diagnostic process, and ideas for diagnostic innovations that could assist them. Data gathered through three focus group discussions (FGG) and 18 individual semi-structured interviews (SSI) with MDs who had completed their medical service in rural areas of Peru in the last two years were analyzed using thematic analysis. Three types of barriers emerged. The first barrier was the limited access to point of care (POC) diagnostic tools. Tests were needed for: i) the differential diagnosis of malaria vs. pneumonia, ii) dengue vs. leptospirosis, iii) tuberculosis, iv) vaginal infections and cervical cancer, v) neurocysticercosis, and vi) heavy metal toxicity. Ultrasound was needed for the diagnosis of obstetric and intra-abdominal conditions. There were also health system-related barriers such as limited funding for diagnostic services, shortage of specialists, limited laboratory services and access to telecommunications, and lack of institutional support. Finally, the third type of barriers included patient related-barriers to follow through with diagnostic referrals. Ideas for innovations proposed included POC equipment and tests, and telemedicine. MDs at primary health facilities in rural Peru face diagnostic challenges that are difficult to overcome due to a limited access to diagnostic tools. Referrals to specialized facilities are constrained by deficiencies in the organization of health services and by barriers that impede the patients' travel to distant health facilities. Technological innovations suggested by the participants such as POC diagnostic tools and mobile-health (m-health) applications could help address part of the problem. However, other types of innovation to address social, adaptation and policy issues should not be dismissed.
Triques, Karine; Sturbois, Bénédicte; Gallais, Stéphane; Dalmais, Marion; Chauvin, Stéphanie; Clepet, Christian; Aubourg, Sébastien; Rameau, Catherine; Caboche, Michel; Bendahmane, Abdelhafid
2007-09-01
Scanning DNA sequences for mutations and polymorphisms has become one of the most challenging, often expensive and time-consuming obstacles in many molecular genetic applications, including reverse genetic and clinical diagnostic applications. Enzymatic mutation detection methods are based on the cleavage of heteroduplex DNA at the mismatch sites. These methods are often limited by the availability of a mismatch-specific endonuclease, their sensitivity in detecting one allele in a pool of DNA and their costs. Here, we present detailed biochemical analysis of five Arabidopsis putative mismatch-specific endonucleases. One of them, ENDO1, is presented as the first endonuclease that recognizes and cleaves all types of mismatches with high efficiency. We report on a very simple protocol for the expression and purification of ENDO1. The ENDO1 system could be exploited in a wide range of mutation diagnostic tools. In particular, we report the use of ENDO1 for discovery of point mutations in the gibberellin 3beta-hydrolase gene of Pisum sativum. Twenty-one independent mutants were isolated, five of these were characterized and two new mutations affecting internodes length were identified. To further evaluate the quality of the mutant population we screened for mutations in four other genes and identified 5-21 new alleles per target. Based on the frequency of the obtained alleles we concluded that the pea population described here would be suitable for use in a large reverse-genetics project.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Morais, A. P.; Salgado de Oliveira University, Marechal Deodoro Street, 217 – Centro, Niterói, Rio de Janeiro; Pino, A. V.
This in vitro study evaluated the diagnostic performance of an alternative electric bioimpedance spectroscopy technique (BIS-STEP) detect questionable occlusal carious lesions. Six specialists carried out the visual (V), radiography (R), and combined (VR) exams of 57 sound or non-cavitated occlusal carious lesion teeth classifying the occlusal surfaces in sound surface (H), enamel caries (EC), and dentinal caries (DC). Measurements were based on the current response to a step voltage excitation (BIS-STEP). A fractional electrical model was used to predict the current response in the time domain and to estimate the model parameters: Rs and Rp (resistive parameters), and C andmore » α (fractional parameters). Histological analysis showed caries prevalence of 33.3% being 15.8% hidden caries. Combined examination obtained the best traditional diagnostic results with specificity = 59.0%, sensitivity = 70.9%, and accuracy = 60.8%. There were statistically significant differences in bioimpedance parameters between the H and EC groups (p = 0.016) and between the H and DC groups (Rs, p = 0.006; Rp, p = 0.022, and α, p = 0.041). Using a suitable threshold for the Rs, we obtained specificity = 60.7%, sensitivity = 77.9%, accuracy = 73.2%, and 100% of detection for deep lesions. It can be concluded that BIS-STEP method could be an important tool to improve the detection and management of occlusal non-cavitated primary caries and pigmented sites.« less
Diagnosing lung cancer using coherent anti-Stokes Raman scattering microscopy
NASA Astrophysics Data System (ADS)
Gao, Liang; Yang, Yaliang; Xing, Jiong; Thrall, Michael J.; Wang, Zhiyong; Li, Fuhai; Luo, Pengfei; Wong, Kelvin K.; Zhao, Hong; Wong, Stephen T. C.
2011-03-01
Lung carcinoma is the most prevalent type of cancer in the world, and it is responsible for more deaths than other types of cancer. During diagnosis, a pathologist primarily aims to differentiate small cell carcinoma from non-small cell carcinoma on biopsy and cytology specimens, which is time consuming due to the time required for tissue processing and staining. To speed up the diagnostic process, we investigated the feasibility of using coherent anti-Stokes Raman scattering (CARS) microscopy as a label-free strategy to image lung lesions and differentiate subtypes of lung cancers. Different mouse lung cancer models were developed by injecting human lung cancer cell lines, including adenocarcinoma, squamous cell carcinoma, and small cell carcinoma, into lungs of the nude mice. CARS images were acquired from normal lung tissues and different subtypes of cancer lesions ex vivo using intrinsic contrasts from symmetric CH2 bonds. These images showed good correlation with the hematoxylin and eosin (H&E) stained sections from the same tissue samples with regard to cell size, density, and cell-cell distance. These features are routinely used in diagnosing lung lesions. Our results showed that the CARS technique is capable of providing a visualizable platform to differentiate different kinds of lung cancers using the same pathological features without histological staining and thus has the potential to serve as a more efficient examination tool for diagnostic pathology. In addition, incorporating with suitable fiber-optic probes would render the CARS technique as a promising approach for in vivo diagnosis of lung cancer.
Time-resolved single-shot terahertz time-domain spectroscopy for ultrafast irreversible processes
NASA Astrophysics Data System (ADS)
Zhai, Zhao-Hui; Zhong, Sen-Cheng; Li, Jun; Zhu, Li-Guo; Meng, Kun; Li, Jiang; Liu, Qiao; Peng, Qi-Xian; Li, Ze-Ren; Zhao, Jian-Heng
2016-09-01
Pulsed terahertz spectroscopy is suitable for spectroscopic diagnostics of ultrafast events. However, the study of irreversible or single shot ultrafast events requires ability to record transient properties at multiple time delays, i.e., time resolved at single shot level, which is not available currently. Here by angular multiplexing use of femtosecond laser pulses, we developed and demonstrated a time resolved, transient terahertz time domain spectroscopy technique, where burst mode THz pulses were generated and then detected in a single shot measurement manner. The burst mode THz pulses contain 2 sub-THz pulses, and the time gap between them is adjustable up to 1 ns with picosecond accuracy, thus it can be used to probe the single shot event at two different time delays. The system can detect the sub-THz pulses at 0.1 THz-2.5 THz range with signal to noise ratio (SNR) of ˜400 and spectrum resolution of 0.05 THz. System design was described here, and optimizations of single shot measurement of THz pulses were discussed in detail. Methods to improve SNR were also discussed in detail. A system application was demonstrated where pulsed THz signals at different time delays of the ultrafast process were successfully acquired within single shot measurement. This time resolved transient terahertz time domain spectroscopy technique provides a new diagnostic tool for irreversible or single shot ultrafast events where dynamic information can be extracted at terahertz range within one-shot experiment.
Health Monitoring Technology for Thermal Protection Systems on Reusable Hypersonic Vehicles
NASA Technical Reports Server (NTRS)
Milos, Frank S.; Watters, D. G.; Heinemann, J. M.; Karunaratne, K. S.; Arnold, Jim (Technical Monitor)
2001-01-01
Integrated subsystem health diagnostics is an area where major improvements have been identified for potential implementation into the design of new reusable launch vehicles (RLVs) in order to reduce life cycle costs, to increase safety margins, and to improve mission reliability. This talk summarizes a joint effort between NASA Ames and industry partners to develop rapid non-contact diagnostic tools for health and performance monitoring of thermal protection systems (TPS) on future RLVs. The specific goals for TPS health monitoring are to increase the speed and reliability of TPS inspections for improved operability at lower cost. The technology being developed includes a 3-D laser scanner for examining the exterior surface of the TPS, and a subsurface microsensor suite for monitoring the health and performance of the TPS. The sensor suite consists of passive overlimit sensors and sensors for continuous parameter monitoring in flight. The sensors are integrated with radio-frequency identification (RFID) microchips to enable wireless communication of-the sensor data to an external reader that may be a hand-held scanner or a large portal. Prototypes of the laser system and both types of subsurface sensors have been developed. The laser scanner was tested on Shuttle Orbiter Columbia and was able to dimension surface chips and holes on a variety of TPS materials. The temperature-overlimit microsensor has a diameter under 0.05 inch (suitable for placement in gaps between ceramic TPS tiles) and can withstand 700 F for 15 minutes.
Time-resolved single-shot terahertz time-domain spectroscopy for ultrafast irreversible processes.
Zhai, Zhao-Hui; Zhong, Sen-Cheng; Li, Jun; Zhu, Li-Guo; Meng, Kun; Li, Jiang; Liu, Qiao; Peng, Qi-Xian; Li, Ze-Ren; Zhao, Jian-Heng
2016-09-01
Pulsed terahertz spectroscopy is suitable for spectroscopic diagnostics of ultrafast events. However, the study of irreversible or single shot ultrafast events requires ability to record transient properties at multiple time delays, i.e., time resolved at single shot level, which is not available currently. Here by angular multiplexing use of femtosecond laser pulses, we developed and demonstrated a time resolved, transient terahertz time domain spectroscopy technique, where burst mode THz pulses were generated and then detected in a single shot measurement manner. The burst mode THz pulses contain 2 sub-THz pulses, and the time gap between them is adjustable up to 1 ns with picosecond accuracy, thus it can be used to probe the single shot event at two different time delays. The system can detect the sub-THz pulses at 0.1 THz-2.5 THz range with signal to noise ratio (SNR) of ∼400 and spectrum resolution of 0.05 THz. System design was described here, and optimizations of single shot measurement of THz pulses were discussed in detail. Methods to improve SNR were also discussed in detail. A system application was demonstrated where pulsed THz signals at different time delays of the ultrafast process were successfully acquired within single shot measurement. This time resolved transient terahertz time domain spectroscopy technique provides a new diagnostic tool for irreversible or single shot ultrafast events where dynamic information can be extracted at terahertz range within one-shot experiment.
Exploration of a leadership competency model for medical school faculties in Korea.
Lee, Yong Seok; Oh, Dong Keun; Kim, Myungun; Lee, Yoon Seong; Shin, Jwa Seop
2010-12-01
To adapt to rapid and turbulent changes in the field of medicine, education, and society, medical school faculties need appropriate leadership. To develop leadership competencies through education, coaching, and mentoring, we need a leadership competency model. The purpose of this study was to develop a new leadership competency model that is suitable for medical school faculties in Korea. To collect behavioral episodes with regard to leadership, we interviewed 54 subjects (faculties, residents, nurses) and surveyed 41 faculties with open-ended questionnaires. We classified the behavioral episodes based on Quinn and Cameron's leadership competency model and developed a Likert scale questionnaire to perform a confirmatory factor analysis. Two hundred seven medical school faculties responded to the questionnaire. The competency clusters that were identified by factor analysis were professionalism, citizenship, leadership, and membership to an organization. Accordingly, each cluster was linked with a dimension: self, society, team (that he/she is leading), and organization (to which he/she belongs). The clusters of competencies were: professional ability, ethics/morality, self-management, self-development, and passion; public interest, networking, social participation, and active service; motivating, caring, promoting teamwork, nurturing, conflict management, directing, performance management, and systems thinking; organizational orientation, collaboration, voluntary participation, and cost-benefit orientation. This competency model that fits medical school faculties in Korea can be used to design and develop selection plans, education programs, feedback tools, diagnostic evaluation tools, and career plan support programs.
Tools for monitoring system suitability in LC MS/MS centric proteomic experiments.
Bereman, Michael S
2015-03-01
With advances in liquid chromatography coupled to tandem mass spectrometry technologies combined with the continued goals of biomarker discovery, clinical applications of established biomarkers, and integrating large multiomic datasets (i.e. "big data"), there remains an urgent need for robust tools to assess instrument performance (i.e. system suitability) in proteomic workflows. To this end, several freely available tools have been introduced that monitor a number of peptide identification (ID) and/or peptide ID free metrics. Peptide ID metrics include numbers of proteins, peptides, or peptide spectral matches identified from a complex mixture. Peptide ID free metrics include retention time reproducibility, full width half maximum, ion injection times, and integrated peptide intensities. The main driving force in the development of these tools is to monitor both intra- and interexperiment performance variability and to identify sources of variation. The purpose of this review is to summarize and evaluate these tools based on versatility, automation, vendor neutrality, metrics monitored, and visualization capabilities. In addition, the implementation of a robust system suitability workflow is discussed in terms of metrics, type of standard, and frequency of evaluation along with the obstacles to overcome prior to incorporating a more proactive approach to overall quality control in liquid chromatography coupled to tandem mass spectrometry based proteomic workflows. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
The ITER bolometer diagnostic: Status and plansa)
NASA Astrophysics Data System (ADS)
Meister, H.; Giannone, L.; Horton, L. D.; Raupp, G.; Zeidner, W.; Grunda, G.; Kalvin, S.; Fischer, U.; Serikov, A.; Stickel, S.; Reichle, R.
2008-10-01
A consortium consisting of four EURATOM Associations has been set up to develop the project plan for the full development of the ITER bolometer diagnostic and to continue urgent R&D activities. An overview of the current status is given, including detector development, line-of-sight optimization, performance analysis as well as the design of the diagnostic components and their integration in ITER. This is complemented by the presentation of plans for future activities required to successfully implement the bolometer diagnostic, ranging from the detector development over diagnostic design and prototype testing to RH tools for calibration.
Building Diagnostic Market Deployment - Final Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Katipamula, S.; Gayeski, N.
2012-04-30
Operational faults are pervasive across the commercial buildings sector, wasting energy and increasing energy costs by up to about 30% (Mills 2009, Liu et al. 2003, Claridge et al. 2000, Katipamula and Brambley 2008, and Brambley and Katipamula 2009). Automated fault detection and diagnostic (AFDD) tools provide capabilities essential for detecting and correcting these problems and eliminating the associated energy waste and costs. The U.S. Department of Energy's (DOE) Building Technology Program (BTP) has previously invested in developing and testing of such diagnostic tools for whole-building (and major system) energy use, air handlers, chillers, cooling towers, chilled-water distribution systems, andmore » boilers. These diagnostic processes can be used to make the commercial buildings more energy efficient. The work described in this report was done as part of a Cooperative Research and Development Agreement (CRADA) between the U.S. Department of Energy's Pacific Northwest National Laboratory (PNNL) and KGS Building LLC (KGS). PNNL and KGS both believe that the widespread adoption of AFDD tools will result in significant reduction to energy and peak energy consumption. The report provides an introduction and summary of the various tasks performed under the CRADA. The CRADA project had three major focus areas: (1) Technical Assistance for Whole Building Energy Diagnostician (WBE) Commercialization, (2) Market Transfer of the Outdoor Air/Economizer Diagnostician (OAE), and (3) Development and Deployment of Automated Diagnostics to Improve Large Commercial Building Operations. PNNL has previously developed two diagnostic tools: (1) whole building energy (WBE) diagnostician and (2) outdoor air/economizer (OAE) diagnostician. WBE diagnostician is currently licensed non-exclusively to one company. As part of this CRADA, PNNL developed implementation documentation and provided technical support to KGS to implement the tool into their software suite, Clockworks. PNNL also provided validation data sets and the WBE software tool to validate the KGS implementation. OAE diagnostician automatically detects and diagnoses problems with outdoor air ventilation and economizer operation for air handling units (AHUs) in commercial buildings using data available from building automation systems (BASs). As part of this CRADA, PNNL developed implementation documentation and provided technical support to KGS to implement the tool into their software suite. PNNL also provided validation data sets and the OAE software tool to validate the KGS implementation. Finally, as part of this CRADA project, PNNL developed new processes to automate parts of the re-tuning process and transfer those process to KGS for integration into their software product. The transfer of DOE-funded technologies will transform the commercial buildings sector by making buildings more energy efficient and also reducing the carbon footprint from the buildings. As part of the CRADA with PNNL, KGS implemented the whole building energy diagnostician, a portion of outdoor air economizer diagnostician and a number of measures that automate the identification of re-tuning measures.« less
2011-03-01
Humansystems® Warfighter Integrated Physical Ergonomics Tool Development Page 14 e) Forces: Griffon seat design assessments include questions of vibration...the suitability of alternative designs . Humansystems® Warfighter Integrated Physical Ergonomics Tool Development Page 5 e) Performance Measures...configurations to assess Humansystems® Warfighter Integrated Physical Ergonomics Tool Development Page 8 design and acquisition decisions, and more
The Individual Basic Facts Assessment Tool
ERIC Educational Resources Information Center
Tait-McCutcheon, Sandi; Drake, Michael
2015-01-01
There is an identified and growing need for a levelled diagnostic basic facts assessment tool that provides teachers with formative information about students' mastery of a broad range of basic fact sets. The Individual Basic Facts Assessment tool has been iteratively and cumulatively developed, trialled, and refined with input from teachers and…
Stokes, Verity; Gunn, Sarah; Schouwenaars, Katie; Badwan, Derar
2018-09-01
The Sensory Tool to Assess Responsiveness (STAR) is an interdisciplinary neurobehavioural diagnostic tool for individuals with prolonged disorders of consciousness. It utilises current diagnostic criteria and is intended to improve upon the high misdiagnosis rate in this population. This study assesses the inter-rater reliability of the STAR and its diagnostic validity in comparison with the Coma Recovery Scale-Revised (CRS-R) and the Wessex Head Injury Matrix (WHIM). Participants were patients with severe acquired brain injury resulting in a disorder of consciousness, who were admitted to the Royal Leamington Spa Rehabilitation Hospital between 1999 and 2009. Patients underwent sensory stimulation sessions during their period of admission, which were recorded on video. Using this footage, patients were re-assessed for this study using the STAR, WHIM and CRS-R criteria. The STAR demonstrated "moderate" inter-rater reliability, "substantial" diagnostic agreement with the CRS-R, and "moderate" agreement with the WHIM. There were no significant differences between diagnoses assigned by the different assessments. The STAR demonstrated a good degree of inter-rater reliability in identification of diagnoses for patients with disorders of consciousness. The diagnostic outcomes of the STAR agreed at a good level with the CRS-R, moderately with the WHIM, and did not significantly differ from either. This demonstrates the reliability and validity of the STAR, showing its appropriateness for clinical use. Future longitudinal studies and research into the STAR's applicability in long-stay rehabilitation are indicated.
Du, Xing; Wang, Feng; Hu, Zhiwei; Wu, Jimin; Wang, Zhonggao; Yan, Chao; Zhang, Chao; Tang, Juan
2017-10-17
None of current diagnostic methods has been proven to be a reliable tool for gastro-esophageal reflux disease (GERD). Pepsin in saliva has been proposed as a promising diagnostic biomarker for gastro-esophageal reflux. We aimed to determine the diagnostic value of salivary pepsin detection for GERD. Two hundred and fifty patients with symptoms suggestive of GERD and 35 asymptomatic healthy volunteers provided saliva on morning waking, after lunch and dinner for pepsin determination using the Peptest lateral flow device. All patients underwent 24-h multichannel intraluminal impedance pH (24-h MII-pH) monitoring and upper gastrointestinal endoscopy. Based on 24-h MII-pH and endoscopy study, patients were defined as GERD (abnormal MII-pH results and/or reflux esophagitis) and non-GERD otherwise. Patients with GERD had a higher prevalence of pepsin in saliva and higher pepsin concentration than patients with non-GERD and healthy controls (P < 0.001 for all). The pepsin test had a sensitivity of 73% and a specificity of 88.3% for diagnosing GERD using the optimal cut-off value of 76 ng/mL. Postprandial saliva samples collected when the symptoms occurred had a more powerful ability to identify GERD. Salivary pepsin test had moderate diagnostic value for GERD. It may be a promising tool to replace the use of currently invasive tools with advantages of non-invasive, easy to perform and cost effective. ChiCTR-DDD-16009506 (date of registration: October 20, 2016).
NASA Astrophysics Data System (ADS)
Chen, Po-Hao; Botzolakis, Emmanuel; Mohan, Suyash; Bryan, R. N.; Cook, Tessa
2016-03-01
In radiology, diagnostic errors occur either through the failure of detection or incorrect interpretation. Errors are estimated to occur in 30-35% of all exams and contribute to 40-54% of medical malpractice litigations. In this work, we focus on reducing incorrect interpretation of known imaging features. Existing literature categorizes cognitive bias leading a radiologist to an incorrect diagnosis despite having correctly recognized the abnormal imaging features: anchoring bias, framing effect, availability bias, and premature closure. Computational methods make a unique contribution, as they do not exhibit the same cognitive biases as a human. Bayesian networks formalize the diagnostic process. They modify pre-test diagnostic probabilities using clinical and imaging features, arriving at a post-test probability for each possible diagnosis. To translate Bayesian networks to clinical practice, we implemented an entirely web-based open-source software tool. In this tool, the radiologist first selects a network of choice (e.g. basal ganglia). Then, large, clearly labeled buttons displaying salient imaging features are displayed on the screen serving both as a checklist and for input. As the radiologist inputs the value of an extracted imaging feature, the conditional probabilities of each possible diagnosis are updated. The software presents its level of diagnostic discrimination using a Pareto distribution chart, updated with each additional imaging feature. Active collaboration with the clinical radiologist is a feasible approach to software design and leads to design decisions closely coupling the complex mathematics of conditional probability in Bayesian networks with practice.
79 FR 4730 - Government-Owned Inventions; Availability for Licensing
Federal Register 2010, 2011, 2012, 2013, 2014
2014-01-29
... patent applications. Novel Targets To Prevent Borrelia burgdorferi Infection and Lyme Disease Description... B. burgdorferi infection by passive immunity and provide new diagnostic tools, which will allow.... burgdorferi diagnostics Prevention of B. burgdorferi infection by passive immunity Zoonotic/tick-borne disease...
NASA Astrophysics Data System (ADS)
Ojaghi, Ashkan; Parkhimchyk, Artur; Tabatabaei, Nima
2016-09-01
Early detection of the most prevalent oral disease worldwide, i.e., dental caries, still remains as one of the major challenges in dentistry. The current dental standard of care relies on caries detection methods, such as visual inspection and x-ray radiography, which lack the sufficient specificity and sensitivity to detect caries at early stages of formation when they can be healed. We report on the feasibility of early caries detection in a clinically and commercially viable thermophotonic imaging system. The system incorporates intensity-modulated laser light along with a low-cost long-wavelength infrared (LWIR; 8 to 14 μm) camera, providing diagnostic contrast based on the enhanced light absorption of early caries. The LWIR camera is highly suitable for integration into clinical platforms because of its low weight and cost. In addition, through theoretical modeling, we show that LWIR detection enhances the diagnostic contrast due to the minimal LWIR transmittance of enamel and suppression of the masking effect of the direct thermal Planck emission. Diagnostic performance of the system and its detection threshold are experimentally evaluated by monitoring the inception and progression of artificially induced occlusal and smooth surface caries. The results are suggestive of the suitability of the developed LWIR system for detecting early dental caries.
Genetic and Diagnostic Biomarker Development in ASD Toddlers Using Resting State Functional MRI
2015-09-01
connectivity networks during natural sleep as a neurologic biomarker for ASD that is suitable for diagnostic use in young children (ages 1-4). Existing... Autism Spectrum Disorders (ASD); functional magnetic resonance imaging (fMRI); connectivity modeling 16. SECURITY CLASSIFICATION OF: 17. LIMITATION...Requirements………………………………….. 4 9. Appendices…………………………………………………………….. 4 1. INTRODUCTION Autism spectrum disorders (ASD), characterized by abnormal
DOE Office of Scientific and Technical Information (OSTI.GOV)
Peruzzo, S., E-mail: simone.peruzzo@igi.cnr.it; Cervaro, V.; Dalla Palma, M.
2016-02-15
This paper presents the results of numerical simulations and experimental tests carried out to assess the feasibility and suitability of graphite castellated tiles as beam-facing component in the diagnostic calorimeter of the negative ion source SPIDER (Source for Production of Ions of Deuterium Extracted from Radio frequency plasma). The results indicate that this concept could be a reliable, although less performing, alternative for the present design based on carbon fiber composite tiles, as it provides thermal measurements on the required spatial scale.
NASA Astrophysics Data System (ADS)
Peruzzo, S.; Cervaro, V.; Dalla Palma, M.; Delogu, R.; De Muri, M.; Fasolo, D.; Franchin, L.; Pasqualotto, R.; Pimazzoni, A.; Rizzolo, A.; Tollin, M.; Zampieri, L.; Serianni, G.
2016-02-01
This paper presents the results of numerical simulations and experimental tests carried out to assess the feasibility and suitability of graphite castellated tiles as beam-facing component in the diagnostic calorimeter of the negative ion source SPIDER (Source for Production of Ions of Deuterium Extracted from Radio frequency plasma). The results indicate that this concept could be a reliable, although less performing, alternative for the present design based on carbon fiber composite tiles, as it provides thermal measurements on the required spatial scale.
Issues in contemporary and potential future molecular diagnostics for dengue.
Sekaran, Shamala Devi; Soe, Hui Jen
2017-03-01
Dengue has been the most common arbovirus infection worldwide with 2.5 billion people living in over 100 endemic tropical and subtropical regions. Due to the high number of asymptomatic cases and the signs and symptoms being rather unspecific, dengue cases are often under-reported and might influence dengue surveillance programs. Therefore, a rapid, easy to use, inexpensive, and highly sensitive and specific diagnostic tool is essential for early and accurate diagnosis to ease the clinical management of patients as well as for the development of new interventions. Areas covered: This report discusses the contemporary dengue diagnostic tool, mainly from the aspect of molecular diagnosis where an overview of several nuclei acid amplification tests has been included. Potential molecular diagnostic tools such as biosensor and microarray are also discussed in this report. Expert commentary: Rapidness and accuracy in terms of sensitivity and specificity is imperative in dengue diagnosis for both clinical management and surveillance of dengue to ensure early treatment and corrective control measures can be carried out. In the next five years it is expected that there will be newer tests developed using not only the lateral flow techniques but more specifically biosensors and nanotechnology. These new technologies will have to be validated with the appropriate number and category of samples and to address the issue of cross-reactivity.
Malaria rapid diagnostic tests in elimination settings—can they find the last parasite?
McMorrow, M. L.; Aidoo, M.; Kachur, S. P.
2016-01-01
Rapid diagnostic tests (RDTs) for malaria have improved the availability of parasite-based diagnosis throughout the malaria-endemic world. Accurate malaria diagnosis is essential for malaria case management, surveillance, and elimination. RDTs are inexpensive, simple to perform, and provide results in 15–20 min. Despite high sensitivity and specificity for Plasmodium falciparum infections, RDTs have several limitations that may reduce their utility in low-transmission settings: they do not reliably detect low-density parasitaemia (≤200 parasites/μL), many are less sensitive for Plasmodium vivax infections, and their ability to detect Plasmodium ovale and Plasmodium malariae is unknown. Therefore, in elimination settings, alternative tools with higher sensitivity for low-density infections (e.g. nucleic acid-based tests) are required to complement field diagnostics, and new highly sensitive and specific field-appropriate tests must be developed to ensure accurate diagnosis of symptomatic and asymptomatic carriers. As malaria transmission declines, the proportion of low-density infections among symptomatic and asymptomatic persons is likely to increase, which may limit the utility of RDTs. Monitoring malaria in elimination settings will probably depend on the use of more than one diagnostic tool in clinical-care and surveillance activities, and the combination of tools utilized will need to be informed by regular monitoring of test performance through effective quality assurance. PMID:21910780
Boerma, Tessel; Chiat, Shula; Leseman, Paul; Timmermeister, Mona; Wijnen, Frank; Blom, Elma
2015-12-01
This study evaluated a newly developed quasi-universal nonword repetition task (Q-U NWRT) as a diagnostic tool for bilingual children with language impairment (LI) who have Dutch as a 2nd language. The Q-U NWRT was designed to be minimally influenced by knowledge of 1 specific language in contrast to a language-specific NWRT with which it was compared. One hundred twenty monolingual and bilingual children with and without LI participated (30 per group). A mixed-design analysis of variance was used to investigate the effects of LI and bilingualism on the NWRTs. Receiver operating characteristic analyses were conducted to evaluate the instruments' diagnostic value. Large negative effects of LI were found on both NWRTs, whereas negative effects of bilingualism only occurred on the language-specific NWRT. Both instruments had high clinical accuracy in the monolingual group, but only the Q-U NWRT had high clinical accuracy in the bilingual group. This study indicates that the Q-U NWRT is a promising diagnostic tool to help identify LI in bilingual children learning Dutch as a 2nd language. The instrument was clinically accurate in both a monolingual and bilingual group of children and seems better able to disentangle LI from language disadvantage than more language-specific measures.
Mast cell activation test in the diagnosis of allergic disease and anaphylaxis.
Bahri, Rajia; Custovic, Adnan; Korosec, Peter; Tsoumani, Marina; Barron, Martin; Wu, Jiakai; Sayers, Rebekah; Weimann, Alf; Ruiz-Garcia, Monica; Patel, Nandinee; Robb, Abigail; Shamji, Mohamed H; Fontanella, Sara; Silar, Mira; Mills, E N Clare; Simpson, Angela; Turner, Paul J; Bulfone-Paus, Silvia
2018-03-05
Food allergy is an increasing public health issue and the most common cause of life-threatening anaphylactic reactions. Conventional allergy tests assess for the presence of allergen-specific IgE, significantly overestimating the rate of true clinical allergy and resulting in overdiagnosis and adverse effect on health-related quality of life. To undertake initial validation and assessment of a novel diagnostic tool, we used the mast cell activation test (MAT). Primary human blood-derived mast cells (MCs) were generated from peripheral blood precursors, sensitized with patients' sera, and then incubated with allergen. MC degranulation was assessed by means of flow cytometry and mediator release. We compared the diagnostic performance of MATs with that of existing diagnostic tools to assess in a cohort of peanut-sensitized subjects undergoing double-blind, placebo-controlled challenge. Human blood-derived MCs sensitized with sera from patients with peanut, grass pollen, and Hymenoptera (wasp venom) allergy demonstrated allergen-specific and dose-dependent degranulation, as determined based on both expression of surface activation markers (CD63 and CD107a) and functional assays (prostaglandin D 2 and β-hexosaminidase release). In this cohort of peanut-sensitized subjects, the MAT was found to have superior discrimination performance compared with other testing modalities, including component-resolved diagnostics and basophil activation tests. Using functional principle component analysis, we identified 5 clusters or patterns of reactivity in the resulting dose-response curves, which at preliminary analysis corresponded to the reaction phenotypes seen at challenge. The MAT is a robust tool that can confer superior diagnostic performance compared with existing allergy diagnostics and might be useful to explore differences in effector cell function between basophils and MCs during allergic reactions. Copyright © 2018 The Authors. Published by Elsevier Inc. All rights reserved.
ERIC Educational Resources Information Center
Bensimon, Moshe; Amir, Dorit
2010-01-01
Musical presentation (MP) is a diagnostic and therapeutic music therapy tool which focuses on the participant's emotional exploration and awareness-insight development. Using this tool people present themselves through music of their choice and subsequently receive feedback from their peers. This study investigates MP as a tool for enhancing…
NASA Technical Reports Server (NTRS)
Ansari, Rafat R.
2004-01-01
The noninvasive techniques of static and dynamic light scattering are emerging as valuable diagnostic tools for the early detection of ocular and systemic diseases. These include corneal abnormalities, pigmentary dispersion syndrome, glaucoma, cataract, diabetic vitreopathy, and possibly macular degeneration. Systemic conditions such as diabetes and possibly Alzheimer's disease can potentially be detected early via ocular tissues. The current state of development of these techniques for application to ophthalmic research and ultimately clinical practice is reviewed. (c) 2004 Society of Photo-Optical Instrumentation Engineers.
Development of Doppler Global Velocimetry as a Flow Diagnostics Tool
NASA Technical Reports Server (NTRS)
Meyers, James F.
1995-01-01
The development of Doppler global velocimetry is described from its inception to its use as a flow diagnostics tool. Its evolution is traced from an elementary one-component laboratory prototype, to a full three-component configuration operating in a wind tunnel at focal distances exceeding 15 m. As part of the developmental process, several wind tunnel flow field investigations were conducted. These included supersonic flow measurements about an oblique shock, subsonic and supersonic measurements of the vortex flow above a delta wing, and three-component measurements of a high-speed jet.
An experimental study of cutting performances in machining of nimonic super alloy GH2312
NASA Astrophysics Data System (ADS)
Du, Jinfu; Wang, Xi; Xu, Min; Mao, Jin; Zhao, Xinglong
2018-05-01
Nimonic super alloy are extensively used in the aerospace industry because of its unique properties. As they are quite costly and difficult to machine, the machining tool is easy to get worn. To solve the problem, an experiment was carried out on a numerical control slitting automatic lathe to analysis the tool wearing conditions and parts' surface quality of nimonic super alloy GH2132 under different cutters. The selection of suitable cutter, reasonable cutting data and cutting speed is obtained and some conclusions are made. The excellent coating tool, compared with other hard alloy cutters, along with suitable cutting data will greatly improve the production efficiency and product quality, it can completely meet the process of nimonic super alloy GH2312.
Translating statistical species-habitat models to interactive decision support tools
Wszola, Lyndsie S.; Simonsen, Victoria L.; Stuber, Erica F.; Gillespie, Caitlyn R.; Messinger, Lindsey N.; Decker, Karie L.; Lusk, Jeffrey J.; Jorgensen, Christopher F.; Bishop, Andrew A.; Fontaine, Joseph J.
2017-01-01
Understanding species-habitat relationships is vital to successful conservation, but the tools used to communicate species-habitat relationships are often poorly suited to the information needs of conservation practitioners. Here we present a novel method for translating a statistical species-habitat model, a regression analysis relating ring-necked pheasant abundance to landcover, into an interactive online tool. The Pheasant Habitat Simulator combines the analytical power of the R programming environment with the user-friendly Shiny web interface to create an online platform in which wildlife professionals can explore the effects of variation in local landcover on relative pheasant habitat suitability within spatial scales relevant to individual wildlife managers. Our tool allows users to virtually manipulate the landcover composition of a simulated space to explore how changes in landcover may affect pheasant relative habitat suitability, and guides users through the economic tradeoffs of landscape changes. We offer suggestions for development of similar interactive applications and demonstrate their potential as innovative science delivery tools for diverse professional and public audiences.
Translating statistical species-habitat models to interactive decision support tools.
Wszola, Lyndsie S; Simonsen, Victoria L; Stuber, Erica F; Gillespie, Caitlyn R; Messinger, Lindsey N; Decker, Karie L; Lusk, Jeffrey J; Jorgensen, Christopher F; Bishop, Andrew A; Fontaine, Joseph J
2017-01-01
Understanding species-habitat relationships is vital to successful conservation, but the tools used to communicate species-habitat relationships are often poorly suited to the information needs of conservation practitioners. Here we present a novel method for translating a statistical species-habitat model, a regression analysis relating ring-necked pheasant abundance to landcover, into an interactive online tool. The Pheasant Habitat Simulator combines the analytical power of the R programming environment with the user-friendly Shiny web interface to create an online platform in which wildlife professionals can explore the effects of variation in local landcover on relative pheasant habitat suitability within spatial scales relevant to individual wildlife managers. Our tool allows users to virtually manipulate the landcover composition of a simulated space to explore how changes in landcover may affect pheasant relative habitat suitability, and guides users through the economic tradeoffs of landscape changes. We offer suggestions for development of similar interactive applications and demonstrate their potential as innovative science delivery tools for diverse professional and public audiences.
Translating statistical species-habitat models to interactive decision support tools
Simonsen, Victoria L.; Stuber, Erica F.; Gillespie, Caitlyn R.; Messinger, Lindsey N.; Decker, Karie L.; Lusk, Jeffrey J.; Jorgensen, Christopher F.; Bishop, Andrew A.; Fontaine, Joseph J.
2017-01-01
Understanding species-habitat relationships is vital to successful conservation, but the tools used to communicate species-habitat relationships are often poorly suited to the information needs of conservation practitioners. Here we present a novel method for translating a statistical species-habitat model, a regression analysis relating ring-necked pheasant abundance to landcover, into an interactive online tool. The Pheasant Habitat Simulator combines the analytical power of the R programming environment with the user-friendly Shiny web interface to create an online platform in which wildlife professionals can explore the effects of variation in local landcover on relative pheasant habitat suitability within spatial scales relevant to individual wildlife managers. Our tool allows users to virtually manipulate the landcover composition of a simulated space to explore how changes in landcover may affect pheasant relative habitat suitability, and guides users through the economic tradeoffs of landscape changes. We offer suggestions for development of similar interactive applications and demonstrate their potential as innovative science delivery tools for diverse professional and public audiences. PMID:29236707
Technological advances in bovine mastitis diagnosis: an overview.
Duarte, Carla M; Freitas, Paulo P; Bexiga, Ricardo
2015-11-01
Bovine mastitis is an economic burden for dairy farmers and preventive control measures are crucial for the sustainability of any dairy business. The identification of etiological agents is necessary in controlling the disease, reducing risk of chronic infections and targeting antimicrobial therapy. The suitability of a detection method for routine diagnosis depends on several factors, including specificity, sensitivity, cost, time in producing results, and suitability for large-scale sampling of milk. This article focuses on current methodologies for identification of mastitis pathogens and for detection of inflammation, as well as the advantages and disadvantages of different methods. Emerging technologies, such as transcriptome and proteome analyses and nano- and microfabrication of portable devices, offer promising, sensitive methods for advanced detection of mastitis pathogens and biomarkers of inflammation. The demand for alternative, fast, and reliable diagnostic procedures is rising as farms become bigger. Several examples of technological and scientific advances are summarized which have given rise to more sensitive, reliable and faster diagnostic results. © 2015 The Author(s).
Monitoring the outcomes of interventions against Taenia solium: options and suggestions.
Lightowlers, M W; Garcia, H H; Gauci, C G; Donadeu, M; Abela-Ridder, B
2016-03-01
There is an increasing interest in reducing the incidence of human neurocysticercosis, caused by infection with the larval stage of Taenia solium. Several intervention trials are currently assessing various options for control of T. solium transmission. A critical aspect of these trials will be the evaluation of whether the interventions have been successful. However, there is no consensus about the most appropriate or valuable methods that should be used. Here, we undertake a critical assessment of the diagnostic tests which are currently available for human T. solium taeniasis and human and porcine cysticercosis, as well as their suitability for evaluation of intervention trial outcomes. Suggestions are made about which of the measures that are available for evaluation of T. solium interventions would be most suitable, and which methodologies are the most appropriate given currently available technologies. Suggestions are also made in relation to the most urgent research needs in order to address deficiencies in current diagnostic methods. © 2015 The Authors. Parasite Immunology Published by John Wiley & Sons Ltd.
Cozzi, Giorgio; Norbedo, Stefania; Barbi, Egidio
2017-04-01
Sedation is often required for children undergoing diagnostic procedures. Chloral hydrate has been one of the sedative drugs most used in children over the last 3 decades, with supporting evidence for its efficacy and safety. Recently, chloral hydrate was banned in Italy and France, in consideration of evidence of its carcinogenicity and genotoxicity. Dexmedetomidine is a sedative with unique properties that has been increasingly used for procedural sedation in children. Several studies demonstrated its efficacy and safety for sedation in non-painful diagnostic procedures. Dexmedetomidine's impact on respiratory drive and airway patency and tone is much less when compared to the majority of other sedative agents. Administration via the intranasal route allows satisfactory procedural success rates. Studies that specifically compared intranasal dexmedetomidine and chloral hydrate for children undergoing non-painful procedures showed that dexmedetomidine was as effective as and safer than chloral hydrate. For these reasons, we suggest that intranasal dexmedetomidine could be a suitable alternative to chloral hydrate.
Medical microbiology: laboratory diagnosis of invasive pneumococcal disease.
Werno, Anja M; Murdoch, David R
2008-03-15
The laboratory diagnosis of invasive pneumococcal disease (IPD) continues to rely on culture-based methods that have been used for many decades. The most significant recent developments have occurred with antigen detection assays, whereas the role of nucleic acid amplification tests has yet to be fully clarified. Despite developments in laboratory diagnostics, a microbiological diagnosis is still not made in most cases of IPD, particularly for pneumococcal pneumonia. The limitations of existing diagnostic tests impact the ability to obtain accurate IPD burden data and to assess the effectiveness of control measures, such as vaccination, in addition to the ability to diagnose IPD in individual patients. There is an urgent need for improved diagnostic tests for pneumococcal disease--especially tests that are suitable for use in underresourced countries.
Are the classic diagnostic methods in mycology still state of the art?
Wiegand, Cornelia; Bauer, Andrea; Brasch, Jochen; Nenoff, Pietro; Schaller, Martin; Mayser, Peter; Hipler, Uta-Christina; Elsner, Peter
2016-05-01
The diagnostic workup of cutaneous fungal infections is traditionally based on microscopic KOH preparations as well as culturing of the causative organism from sample material. Another possible option is the detection of fungal elements by dermatohistology. If performed correctly, these methods are generally suitable for the diagnosis of mycoses. However, the advent of personalized medicine and the tasks arising therefrom require new procedures marked by simplicity, specificity, and swiftness. The additional use of DNA-based molecular techniques further enhances sensitivity and diagnostic specificity, and reduces the diagnostic interval to 24-48 hours, compared to weeks required for conventional mycological methods. Given the steady evolution in the field of personalized medicine, simple analytical PCR-based systems are conceivable, which allow for instant diagnosis of dermatophytes in the dermatology office (point-of-care tests). © 2016 Deutsche Dermatologische Gesellschaft (DDG). Published by John Wiley & Sons Ltd.
Ramnarayan, Padmanabhan; Kapoor, Ritika R; Coren, Michael; Nanduri, Vasantha; Tomlinson, Amanda L; Taylor, Paul M; Wyatt, Jeremy C; Britto, Joseph F
2003-01-01
Few previous studies evaluating the benefits of diagnostic decision support systems have simultaneously measured changes in diagnostic quality and clinical management prompted by use of the system. This report describes a reliable and valid scoring technique to measure the quality of clinical decision plans in an acute medical setting, where diagnostic decision support tools might prove most useful. Sets of differential diagnoses and clinical management plans generated by 71 clinicians for six simulated cases, before and after decision support from a Web-based pediatric differential diagnostic tool (ISABEL), were used. A composite quality score was calculated separately for each diagnostic and management plan by considering the appropriateness value of each component diagnostic or management suggestion, a weighted sum of individual suggestion ratings, relevance of the entire plan, and its comprehensiveness. The reliability and validity (face, concurrent, construct, and content) of these two final scores were examined. Two hundred fifty-two diagnostic and 350 management suggestions were included in the interrater reliability analysis. There was good agreement between raters (intraclass correlation coefficient, 0.79 for diagnoses, and 0.72 for management). No counterintuitive scores were demonstrated on visual inspection of the sets. Content validity was verified by a consultation process with pediatricians. Both scores discriminated adequately between the plans of consultants and medical students and correlated well with clinicians' subjective opinions of overall plan quality (Spearman rho 0.65, p < 0.01). The diagnostic and management scores for each episode showed moderate correlation (r = 0.51). The scores described can be used as key outcome measures in a larger study to fully assess the value of diagnostic decision aids, such as the ISABEL system.
LAMP detection assays for boxwood blight pathogens: a comparative genomics approach
USDA-ARS?s Scientific Manuscript database
Rapid and accurate molecular diagnostic tools are critical to efforts to minimize the impact and spread of emergent pathogens. The identification of diagnostic markers for novel pathogens presents several challenges, especially in the absence of information about population diversity, and where gen...
ERIC Educational Resources Information Center
Klose, Laurie McGarry; Plotts, Cynthia; Kozeneski, Nicole; Skinner-Foster, Jacqueline
2012-01-01
This paper provides a review of widely used measures for assessing Autism Spectrum Disorders, including the "Autism Diagnostic Interview-Revised," "Autism Diagnostic Observation Schedule," "Psychoeducational Profile-Third Edition," "Gilliam Autism Rating Scale-Second Edition," and "Childhood Autism…
Lewis-Fernández, Roberto; Aggarwal, Neil Krishan; Lam, Peter C; Galfalvy, Hanga; Weiss, Mitchell G; Kirmayer, Laurence J; Paralikar, Vasudeo; Deshpande, Smita N; Díaz, Esperanza; Nicasio, Andel V; Boiler, Marit; Alarcón, Renato D; Rohlof, Hans; Groen, Simon; van Dijk, Rob C J; Jadhav, Sushrut; Sarmukaddam, Sanjeev; Ndetei, David; Scalco, Monica Z; Bassiri, Kavoos; Aguilar-Gaxiola, Sergio; Ton, Hendry; Westermeyer, Joseph; Vega-Dienstmaier, Johann M
2017-04-01
Background There is a need for clinical tools to identify cultural issues in diagnostic assessment. Aims To assess the feasibility, acceptability and clinical utility of the DSM-5 Cultural Formulation Interview (CFI) in routine clinical practice. Method Mixed-methods evaluation of field trial data from six countries. The CFI was administered to diagnostically diverse psychiatric out-patients during a diagnostic interview. In post-evaluation sessions, patients and clinicians completed debriefing qualitative interviews and Likert-scale questionnaires. The duration of CFI administration and the full diagnostic session were monitored. Results Mixed-methods data from 318 patients and 75 clinicians found the CFI feasible, acceptable and useful. Clinician feasibility ratings were significantly lower than patient ratings and other clinician-assessed outcomes. After administering one CFI, however, clinician feasibility ratings improved significantly and subsequent interviews required less time. Conclusions The CFI was included in DSM-5 as a feasible, acceptable and useful cultural assessment tool. © The Royal College of Psychiatrists 2017.
DNA microarray technology in nutraceutical and food safety.
Liu-Stratton, Yiwen; Roy, Sashwati; Sen, Chandan K
2004-04-15
The quality and quantity of diet is a key determinant of health and disease. Molecular diagnostics may play a key role in food safety related to genetically modified foods, food-borne pathogens and novel nutraceuticals. Functional outcomes in biology are determined, for the most part, by net balance between sets of genes related to the specific outcome in question. The DNA microarray technology offers a new dimension of strength in molecular diagnostics by permitting the simultaneous analysis of large sets of genes. Automation of assay and novel bioinformatics tools make DNA microarrays a robust technology for diagnostics. Since its development a few years ago, this technology has been used for the applications of toxicogenomics, pharmacogenomics, cell biology, and clinical investigations addressing the prevention and intervention of diseases. Optimization of this technology to specifically address food safety is a vast resource that remains to be mined. Efforts to develop diagnostic custom arrays and simplified bioinformatics tools for field use are warranted.
Kriegsmann, Jörg; Kriegsmann, Mark; Casadonte, Rita
2015-03-01
Matrix-assisted laser desorption/ionization (MALDI) time-of-flight (TOF) imaging mass spectrometry (IMS) is an evolving technique in cancer diagnostics and combines the advantages of mass spectrometry (proteomics), detection of numerous molecules, and spatial resolution in histological tissue sections and cytological preparations. This method allows the detection of proteins, peptides, lipids, carbohydrates or glycoconjugates and small molecules.Formalin-fixed paraffin-embedded tissue can also be investigated by IMS, thus, this method seems to be an ideal tool for cancer diagnostics and biomarker discovery. It may add information to the identification of tumor margins and tumor heterogeneity. The technique allows tumor typing, especially identification of the tumor of origin in metastatic tissue, as well as grading and may provide prognostic information. IMS is a valuable method for the identification of biomarkers and can complement histology, immunohistology and molecular pathology in various fields of histopathological diagnostics, especially with regard to identification and grading of tumors.
Democratizing molecular diagnostics for the developing world.
Abou Tayoun, Ahmad N; Burchard, Paul R; Malik, Imran; Scherer, Axel; Tsongalis, Gregory J
2014-01-01
Infectious diseases that are largely treatable continue to pose a tremendous burden on the developing world despite the availability of highly potent drugs. The high mortality and morbidity rates of these diseases are largely due to a lack of affordable diagnostics that are accessible to resource-limited areas and that can deliver high-quality results. In fact, modified molecular diagnostics for infectious diseases were rated as the top biotechnology to improve health in developing countries. In this review, we describe the characteristics of accessible molecular diagnostic tools and discuss the challenges associated with implementing such tools at low infrastructure sites. We highlight our experience as part of the "Grand Challenge" project supported by the Gates Foundation for addressing global health inequities and describe issues and solutions associated with developing adequate technologies or molecular assays needed for broad access in the developing world. We believe that sharing this knowledge will facilitate the development of new molecular technologies that are extremely valuable for improving global health.
Research of Extension of the Life Cycle of Helicopter Rotor Blade in Hungary
2003-02-01
Radiography (DXR), and (iii) Vibration Diagnostics (VD) with Statistical Energy Analysis (SEA) were semi- simultaneously applied [1]. The used three...2.2. Vibration Diagnostics (VD)) Parallel to the NDT measurements the Statistical Energy Analysis (SEA) as a vibration diagnostical tool were...noises were analysed with a dual-channel real time frequency analyser (BK2035). In addition to the Statistical Energy Analysis measurement a small
Application of Diagnostic Analysis Tools to the Ares I Thrust Vector Control System
NASA Technical Reports Server (NTRS)
Maul, William A.; Melcher, Kevin J.; Chicatelli, Amy K.; Johnson, Stephen B.
2010-01-01
The NASA Ares I Crew Launch Vehicle is being designed to support missions to the International Space Station (ISS), to the Moon, and beyond. The Ares I is undergoing design and development utilizing commercial-off-the-shelf tools and hardware when applicable, along with cutting edge launch technologies and state-of-the-art design and development. In support of the vehicle s design and development, the Ares Functional Fault Analysis group was tasked to develop an Ares Vehicle Diagnostic Model (AVDM) and to demonstrate the capability of that model to support failure-related analyses and design integration. One important component of the AVDM is the Upper Stage (US) Thrust Vector Control (TVC) diagnostic model-a representation of the failure space of the US TVC subsystem. This paper first presents an overview of the AVDM, its development approach, and the software used to implement the model and conduct diagnostic analysis. It then uses the US TVC diagnostic model to illustrate details of the development, implementation, analysis, and verification processes. Finally, the paper describes how the AVDM model can impact both design and ground operations, and how some of these impacts are being realized during discussions of US TVC diagnostic analyses with US TVC designers.
Might telesonography be a new useful diagnostic tool aboard merchant ships? A pilot study.
Nikolić, Nebojsa; Mozetić, Vladimir; Modrcin, Bob; Jaksić, Slaven
2006-01-01
Developments of new, ultra-light diagnostic ultrasound systems (UTS) and modern satellite telecommunication networks are opening new potential applications for diagnostic sonography. One such area is maritime medicine. It is our belief that ship officers can be trained to use diagnostic ultrasound systems with the aim to generate ultrasound images of sufficient quality to be interpreted by medical professionals qualified to read sonograms. To test our thesis we included lectures and hands on scanning practice to the current maritime medicine curriculum at the Faculty of Maritime Studies at the University of Rijeka. Following the didactic and practical training all participating students examined several patients, some with pathology some without. Images obtained by students were then submitted for interpretation to a qualified physician (specialist of general surgery trained in UTS) who was unaware of the patient's pathology. In total, 37 students performed 37 examinations and made 45 ultrasound images, on 3 patients. In this paper, results on this pilot study are presented. It is possible to teach ship officers to produce diagnostically usable ultrasound pictures aboard ships at sea. But before reaching final conclusion about applicability of telesonography on board merchant ships, further studies are necessary, that would include studies of economic feasibility, and on validity of introducing such a diagnostic tool to the maritime medical practice.
A Research Agenda for Malaria Eradication: Diagnoses and Diagnostics
2011-01-01
Many of malaria's signs and symptoms are indistinguishable from those of other febrile diseases. Detection of the presence of Plasmodium parasites is essential, therefore, to guide case management. Improved diagnostic tools are required to enable targeted treatment of infected individuals. In addition, field-ready diagnostic tools for mass screening and surveillance that can detect asymptomatic infections of very low parasite densities are needed to monitor transmission reduction and ensure elimination. Antibody-based tests for infection and novel methods based on biomarkers need further development and validation, as do methods for the detection and treatment of Plasmodium vivax. Current rapid diagnostic tests targeting P. vivax are generally less effective than those targeting Plasmodium falciparum. Moreover, because current drugs for radical cure may cause serious side effects in patients with glucose-6-phosphate dehydrogenase (G6PD) deficiency, more information is needed on the distribution of G6PD-deficiency variants as well as tests to identify at-risk individuals. Finally, in an environment of very low or absent malaria transmission, sustaining interest in elimination and maintaining resources will become increasingly important. Thus, research is required into the context in which malaria diagnostic tests are used, into diagnostics for other febrile diseases, and into the integration of these tests into health systems. PMID:21311583
New V and V Tools for Diagnostic Modeling Environment (DME)
NASA Technical Reports Server (NTRS)
Pecheur, Charles; Nelson, Stacy; Merriam, Marshall (Technical Monitor)
2002-01-01
The purpose of this report is to provide correctness and reliability criteria for verification and validation (V&V) of Second Generation Reusable Launch Vehicle (RLV) Diagnostic Modeling Environment, describe current NASA Ames Research Center tools for V&V of Model Based Reasoning systems, and discuss the applicability of Advanced V&V to DME. This report is divided into the following three sections: (1) correctness and reliability criteria; (2) tools for V&V of Model Based Reasoning; and (3) advanced V&V applicable to DME. The Executive Summary includes an overview of the main points from each section. Supporting details, diagrams, figures, and other information are included in subsequent sections. A glossary, acronym list, appendices, and references are included at the end of this report.
Tam, Teck Lip Dexter; Lin, Ting Ting; Chua, Ming Hui
2017-06-21
Here we utilized new diagnostic tools in time-dependent density functional theory to explain the trend of intersystem crossing in benzo(bis)-X-diazole based donor-acceptor-donor type molecules. These molecules display a wide range of fluorescence quantum yields and triplet yields, making them excellent candidates for testing the validity of these diagnostic tools. We believe that these tools are cost-effective and can be applied to structurally similar organic chromophores to predict/explain the trends of intersystem crossing, and thus fluorescence quantum yields and triplet yields without the use of complex and expensive multireference configuration interaction or multireference pertubation theory methods.
Physics meets fine arts: a project-based learning path on infrared imaging
NASA Astrophysics Data System (ADS)
Bonanno, A.; Bozzo, G.; Sapia, P.
2018-03-01
Infrared imaging represents a noninvasive tool for cultural heritage diagnostics, based on the capability of IR radiation to penetrate the most external layers of different objects (as for example paintings), revealing hidden features of artworks. From an educational viewpoint, this diagnostic technique offers teachers the opportunity to address manifold topics pertaining to the physics and technology of electromagnetic radiation, with particular emphasis on the nature of color and its physical correlates. Moreover, the topic provides interesting interdisciplinary bridges towards the human sciences. In this framework, we present a hands-on learning sequence, suitable for both high school students and university freshmen, inspired by the project-based learning (PBL) paradigm, designed and implemented in the context of an Italian national project aimed at offering students the opportunity to participate in educational activities within a real working context. In a preliminary test we involved a group of 23 high school students while they were working as apprentices in the Laboratory of Applied Physics for Cultural Heritage (ArcheoLab) at the University of Calabria. Consistently with the PBL paradigm, students were given well-defined practical goals to be achieved. As final goals they were asked (i) to construct and to test a low cost device (based on a disused commercial camera) appropriate for performing educational-grade IR investigations on paintings, and (ii) to prepare a device working as a simple spectrometer (recycling the optical components of a disused video projector), suitable for characterizing various light sources in order to identify the most appropriate for infrared imaging. The proposed learning path has shown (in the preliminary test) to be effective in fostering students’ interest towards physics and its technological applications, especially because pupils perceived the context (i.e. physics applied to the protection and restoration of cultural heritage) as relevant in relation to the cultural and productive specificities of their country. The learning sequence, originally designed for high school students in apprenticeship at the university, can be easily improved to make it appropriate for university freshmen.
Kam, Sung Chul; Han, Deok Hyun; Lee, Sung Won
2011-03-01
Premature ejaculation (PE) is the most prevalent male ejaculation disorder. The premature ejaculation diagnostic tool (PEDT) was developed to systematically apply the DSM-IV-TR criteria in diagnostic PE. To evaluate the diagnostic value of the PEDT and its association with intravaginal ejaculatory latency time (IELT). (i) Korean validation of PEDT: data was collected from men interviewed by one of the two clinical experts, who made a diagnostic of present or absence of PE, using DSM-IV-TR criteria. A total of 103 patients with PE and 100 men without PE were enrolled into the study and requested to complete the PEDT; and (ii) The correlation between IELT and PEDT: 200 participants were enrolled and each participant was asked to make out PEDT. All participants were requested to measure IELT. Validity and reliability of the PEDT and its association with IELT. The geometric mean IELT of the PE group was 115.37 ± 78.14 seconds. The number of men reporting IELTs of <1, 1 to ≤ 2, and >2 minutes were 28 (28.6%), 29 (29.6%), and 41 (41.8%), respectively. The Cronbach's alpha score was calculated as 0.93, showing adequate internal consistency. The test-retest correlation coefficients of each item were higher than 0.72 and the correlation coefficients of the total score was 0.88. (P < 0.001) Sensitivity and specificity analyses suggested a score of ≤ 8 indicated no PE, 9 and 10 probable PE, and ≥ 11 PE. The PEDT total score and IELT showed an adequate negative correlation. (ρ = -0.77, P < 0.0001) also, the PEDT total score of the PE subgroup (IELT ≤ 2 minutes) and IELT showed a negative correlation. (ρ = -0.6, P < 0.0001) The PEDT was highly effective in detecting the presence of PE. The result of our study supports its validity as a diagnostic tool in the clinical setting. © 2010 International Society for Sexual Medicine.
Li, Rui; Liu, Jianjun; Xue, Huiping; Huang, Gang
2012-10-15
The measurement of fecal tumor M2-pyruvate kinase (PKM2), overexpressed in tumor cells, has been proposed as a novel tool for detecting colorectal cancer (CRC). However, the sensitivity and specificity of this test varied among studies. The aim of this meta-analysis was to determine the diagnostic accuracy of fecal PKM2 for CRC and to evaluate its utility in the CRC screening. It was compared to guaiac fecal occult blood test (gFOBT) or immunological fecal occult blood test (iFOBT). Through comprehensive literature search, 10 studies met the inclusion criteria and were included. Summary estimates for sensitivity and specificity were calculated by using the bivariate random effect model. The hierarchical summary receiver operating characteristic curve was also undertaken. The overall sensitivity and specificity of fecal PKM2 for detecting CRC were 79% (95% CI = 75-83%) and 81% (95% CI = 73-87%), respectively. The summary positive predictive value and negative predictive value were 74% (95% CI = 56-87%) and 86% (95% CI = 79-91%), respectively. The pooled diagnostic odds ratio was 16 (95% CI = 10-26). In head-to-head comparison, the diagnostic odds ratio of PKM2 and gFOBT for CRC were 10.167 (95% CI = 5.992-17.250) and 6.557 (95% CI = 3.467-12.403), respectively. The diagnostic odds ratio of PKM2 and iFOBT for CRC were 9.542 (95% CI = 5.893-15.452) and 67.248 (95% CI = 16.194-279.26), respectively. The fecal PKM2 test was a diagnostic tool with moderate sensitivity and specificity for detecting CRC. Its diagnostic efficiency was similar to that of gFOBT. Because of its relatively low specificity and positive predict value, fecal PKM2 was not recommended used alone as a screening tool for CRC. Copyright © 2012 UICC.
Suitability evaluation tool for lands (rice, corn and soybean) as mobile application
NASA Astrophysics Data System (ADS)
Rahim, S. E.; Supli, A. A.; Damiri, N.
2017-09-01
Evaluation of land suitability for special purposes e.g. for food crops is a must, a means to understand determining factors to be considered in the management of a land successfully. A framework for evaluating the land suitability for purposes in agriculture was first introduced by the Food and Agriculture Organization (FAO) in late 1970s. When using the framework manually, it is time consuming and not interesting for land users. Therefore, the authors have developed an effective tool by transforming the FAO framework into smart mobile application. This application is designed by using simple language for each factor and also by utilizing rule based system (RBS) algorithm. The factors involved are soil type, depth of soil solum, soil fertility, soil pH, drainage, risk of flood, etc. Suitability in this paper is limited to rice, corn and soybean. The application is found to be easier to understand and also could automatically determine the suitability of land. Usability testing was also conducted with 75 respondents. The results showed the usability was in "very good" classification. The program is urgently needed by the land managers, farmers, lecturers, students and government officials (planners) to help them more easily manage their land for a better future.
A hybrid framework for quantifying the influence of data in hydrological model calibration
NASA Astrophysics Data System (ADS)
Wright, David P.; Thyer, Mark; Westra, Seth; McInerney, David
2018-06-01
Influence diagnostics aim to identify a small number of influential data points that have a disproportionate impact on the model parameters and/or predictions. The key issues with current influence diagnostic techniques are that the regression-theory approaches do not provide hydrologically relevant influence metrics, while the case-deletion approaches are computationally expensive to calculate. The main objective of this study is to introduce a new two-stage hybrid framework that overcomes these challenges, by delivering hydrologically relevant influence metrics in a computationally efficient manner. Stage one uses computationally efficient regression-theory influence diagnostics to identify the most influential points based on Cook's distance. Stage two then uses case-deletion influence diagnostics to quantify the influence of points using hydrologically relevant metrics. To illustrate the application of the hybrid framework, we conducted three experiments on 11 hydro-climatologically diverse Australian catchments using the GR4J hydrological model. The first experiment investigated how many data points from stage one need to be retained in order to reliably identify those points that have the hightest influence on hydrologically relevant metrics. We found that a choice of 30-50 is suitable for hydrological applications similar to those explored in this study (30 points identified the most influential data 98% of the time and reduced the required recalibrations by 99% for a 10 year calibration period). The second experiment found little evidence of a change in the magnitude of influence with increasing calibration period length from 1, 2, 5 to 10 years. Even for 10 years the impact of influential points can still be high (>30% influence on maximum predicted flows). The third experiment compared the standard least squares (SLS) objective function with the weighted least squares (WLS) objective function on a 10 year calibration period. In two out of three flow metrics there was evidence that SLS, with the assumption of homoscedastic residual error, identified data points with higher influence (largest changes of 40%, 10%, and 44% for the maximum, mean, and low flows, respectively) than WLS, with the assumption of heteroscedastic residual errors (largest changes of 26%, 6%, and 6% for the maximum, mean, and low flows, respectively). The hybrid framework complements existing model diagnostic tools and can be applied to a wide range of hydrological modelling scenarios.
Update on Supersonic Jet Noise Research at NASA
NASA Technical Reports Server (NTRS)
Henderson, Brenda
2010-01-01
An update on jet noise research conducted in the Fundamental Aeronautics and Integrated Systems Research Programs was presented. Highlighted research projects included those focused on the development of prediction tools, diagnostic tools, and noise reduction concepts.
Hemingway, Janet; Shretta, Rima; Wells, Timothy N. C.; Bell, David; Djimdé, Abdoulaye A.; Achee, Nicole; Qi, Gao
2016-01-01
Progress made in malaria control during the past decade has prompted increasing global dialogue on malaria elimination and eradication. The product development pipeline for malaria has never been stronger, with promising new tools to detect, treat, and prevent malaria, including innovative diagnostics, medicines, vaccines, vector control products, and improved mechanisms for surveillance and response. There are at least 25 projects in the global malaria vaccine pipeline, as well as 47 medicines and 13 vector control products. In addition, there are several next-generation diagnostic tools and reference methods currently in development, with many expected to be introduced in the next decade. The development and adoption of these tools, bolstered by strategies that ensure rapid uptake in target populations, intensified mechanisms for information management, surveillance, and response, and continued financial and political commitment are all essential to achieving global eradication. PMID:26934361
Hemingway, Janet; Shretta, Rima; Wells, Timothy N C; Bell, David; Djimdé, Abdoulaye A; Achee, Nicole; Qi, Gao
2016-03-01
Progress made in malaria control during the past decade has prompted increasing global dialogue on malaria elimination and eradication. The product development pipeline for malaria has never been stronger, with promising new tools to detect, treat, and prevent malaria, including innovative diagnostics, medicines, vaccines, vector control products, and improved mechanisms for surveillance and response. There are at least 25 projects in the global malaria vaccine pipeline, as well as 47 medicines and 13 vector control products. In addition, there are several next-generation diagnostic tools and reference methods currently in development, with many expected to be introduced in the next decade. The development and adoption of these tools, bolstered by strategies that ensure rapid uptake in target populations, intensified mechanisms for information management, surveillance, and response, and continued financial and political commitment are all essential to achieving global eradication.
Medical Community of Inquiry: A Diagnostic Tool for Learning, Assessment, and Research
ERIC Educational Resources Information Center
Nave, Rachel; Ackerman, Rakefet; Dori, Yehudit Judy
2017-01-01
Aim/Purpose: These days educators are expected to integrate technological tools into classes. Although they acquire relevant skills, they are often reluctant to use these tools. Background: We incorporated online forums for generating a Community of Inquiry (CoI) in a faculty development program. Extending the Technology, Pedagogy, and Content…
Prostate cancer: predicting high-risk prostate cancer-a novel stratification tool.
Buck, Jessica; Chughtai, Bilal
2014-05-01
Currently, numerous systems exist for the identification of high-risk prostate cancer, but few of these systems can guide treatment strategies. A new stratification tool that uses common diagnostic factors can help to predict outcomes after radical prostatectomy. The tool aids physicians in the identification of appropriate candidates for aggressive, local treatment.
Reflectometric measurement of plasma imaging and applications
NASA Astrophysics Data System (ADS)
Mase, A.; Ito, N.; Oda, M.; Komada, Y.; Nagae, D.; Zhang, D.; Kogi, Y.; Tobimatsu, S.; Maruyama, T.; Shimazu, H.; Sakata, E.; Sakai, F.; Kuwahara, D.; Yoshinaga, T.; Tokuzawa, T.; Nagayama, Y.; Kawahata, K.; Yamaguchi, S.; Tsuji-Iio, S.; Domier, C. W.; Luhmann, N. C., Jr.; Park, H. K.; Yun, G.; Lee, W.; Padhi, S.; Kim, K. W.
2012-01-01
Progress in microwave and millimeter-wave technologies has made possible advanced diagnostics for application to various fields, such as, plasma diagnostics, radio astronomy, alien substance detection, airborne and spaceborne imaging radars called as synthetic aperture radars, living body measurements. Transmission, reflection, scattering, and radiation processes of electromagnetic waves are utilized as diagnostic tools. In this report we focus on the reflectometric measurements and applications to biological signals (vital signal detection and breast cancer detection) as well as plasma diagnostics, specifically by use of imaging technique and ultra-wideband radar technique.
Accuracy of Urine Color to Detect Equal to or Greater Than 2% Body Mass Loss in Men.
McKenzie, Amy L; Muñoz, Colleen X; Armstrong, Lawrence E
2015-12-01
Clinicians and athletes can benefit from field-expedient measurement tools, such as urine color, to assess hydration state; however, the diagnostic efficacy of this tool has not been established. To determine the diagnostic accuracy of urine color assessment to distinguish a hypohydrated state (≥2% body mass loss [BML]) from a euhydrated state (<2% BML) after exercise in a hot environment. Controlled laboratory study. Environmental chamber in a laboratory. Twenty-two healthy men (age = 22 ± 3 years, height = 180.4 ± 8.7 cm, mass = 77.9 ± 12.8 kg, body fat = 10.6% ± 4.6%). Participants cycled at 68% ± 6% of their maximal heart rates in a hot environment (36°C ± 1°C) for 5 hours or until 5% BML was achieved. At the point of each 1% BML, we assessed urine color. Diagnostic efficacy of urine color was assessed using receiver operating characteristic curve analysis, sensitivity, specificity, and likelihood ratios. Urine color was useful as a diagnostic tool to identify hypohydration after exercise in the heat (area under the curve = 0.951, standard error = 0.022; P < .001). A urine color of 5 or greater identified BML ≥2% with 88.9% sensitivity and 84.8% specificity (positive likelihood ratio = 5.87, negative likelihood ratio = 0.13). Under the conditions of acute dehydration due to exercise in a hot environment, urine color assessment can be a valid, practical, inexpensive tool for assessing hydration status. Researchers should examine the utility of urine color to identify a hypohydrated state under different BML conditions.
Engineered Aptamers to Probe Molecular Interactions on the Cell Surface
Batool, Sana; Bhandari, Sanam; George, Shanell; Okeoma, Precious; Van, Nabeela; Zümrüt, Hazan E.; Mallikaratchy, Prabodhika
2017-01-01
Significant progress has been made in understanding the nature of molecular interactions on the cell membrane. To decipher such interactions, molecular scaffolds can be engineered as a tool to modulate these events as they occur on the cell membrane. To guarantee reliability, scaffolds that function as modulators of cell membrane events must be coupled to a targeting moiety with superior chemical versatility. In this regard, nucleic acid aptamers are a suitable class of targeting moieties. Aptamers are inherently chemical in nature, allowing extensive site-specific chemical modification to engineer sensing molecules. Aptamers can be easily selected using a simple laboratory-based in vitro evolution method enabling the design and development of aptamer-based functional molecular scaffolds against wide range of cell surface molecules. This article reviews the application of aptamers as monitors and modulators of molecular interactions on the mammalian cell surface with the aim of increasing our understanding of cell-surface receptor response to external stimuli. The information gained from these types of studies could eventually prove useful in engineering improved medical diagnostics and therapeutics. PMID:28850067
Nucleic acid-based electrochemical nanobiosensors.
Abi, Alireza; Mohammadpour, Zahra; Zuo, Xiaolei; Safavi, Afsaneh
2018-04-15
The detection of biomarkers using sensitive and selective analytical devices is critically important for the early stage diagnosis and treatment of diseases. The synergy between the high specificity of nucleic acid recognition units and the great sensitivity of electrochemical signal transductions has already shown promise for the development of efficient biosensing platforms. Yet nucleic-acid based electrochemical biosensors often rely on target amplification strategies (e.g., polymerase chain reactions) to detect analytes at clinically relevant concentration ranges. The complexity and time-consuming nature of these amplification methods impede moving nucleic acid-based electrochemical biosensors from laboratory-based to point-of-care test settings. Fortunately, advancements in nanotechnology have provided growing evidence that the recruitment of nanoscaled materials and structures can enhance the biosensing performance (particularly in terms of sensitivity and response time) to the level suitable for use in point-of-care diagnostic tools. This Review highlights the significant progress in the field of nucleic acid-based electrochemical nanobiosensing with the focus on the works published during the last five years. Copyright © 2017. Published by Elsevier B.V.
Bispectral analysis: comparison of two windowing functions
NASA Astrophysics Data System (ADS)
Silvagni, D.; Djerroud, C.; Réveillé, T.; Gravier, E.
2018-02-01
Amongst all the normalized forms of bispectrum, the bicoherence is shown to be a very useful diagnostic tool in experimental studies of nonlinear wave interactions in plasma, as it measures the fraction of wave power due to the quadratic wave coupling in a self-excited fluctuation spectrum [1, 2]. In order to avoid spectral leakage, the application of a windowing function is needed during the bicoherence computation. Spectral leakage from statistically dependent components are of crucial importance in the discrimination between coupled and uncoupled modes, as they will introduce in the bicoherence spectrum phase-coupled modes which in reality do not exist. Therefore, the windowing function plays a key role in the bicoherence estimation. In this paper, two windowing methods are compared: the multiplication of the initial signal by the Hanning function and the subtraction of the straight line which links the two extremities of the signal. The influence of these two windowing methods on both the power spectrum and the bicoherence spectrum is showed. Although both methods give precise results, the Hanning function appears to be the more suitable window.
Consultation of orthopaedics cases using multimedia messaging services.
Eranki, Vivek; Munt, Justin; Lim, Ming J; Atkinson, Robert
2010-04-23
Frequently, radiological data is transferred verbally between the Emergency Department (ED) and orthopaedic registrar. Given the different language skills and medical experience of health staff, there is often a limit to the adequacy of the verbal description that could lead to suboptimal patient care. This study proposes that concurrent review of MMS teleradiology with traditional verbal reporting results in a significant therapeutic benefit. Case notes of 40 patients who presented to ED were reviewed. Images were captured and sent to an Orthopaedic registrar along with a brief clinical synopsis. Information was collected on the diagnosis of the MMS radiograph, need for urgent admission and management plan outlined to ED. Correct diagnosis was made in 27 of 40 cases. Using the latest technology available, MMS teleradiology had 79% sensitivity, 83% specificity and an accuracy of 80%. 50% of paediatric fractures and 60% of undisplaced fractures were diagnosed successfully. MMS teleradiology is not suitable by itself as a remote diagnostic tool. However, when combined with existing clinical practice, it is effective in screening patients, enhances confidence in decision making and communication between doctors.
Leptospira species molecular epidemiology in the genomic era.
Caimi, K; Repetto, S A; Varni, V; Ruybal, P
2017-10-01
Leptospirosis is a zoonotic disease which global burden is increasing often related to climatic change. Hundreds of whole genome sequences from worldwide isolates of Leptospira spp. are available nowadays, together with online tools that permit to assign MLST sequence types (STs) directly from raw sequence data. In this work we have applied R7L-MLST to near 500 genomes and strains collection globally distributed. All 10 pathogenic species as well as intermediate were typed using this MLST scheme. The correlation observed between STs and serogroups in our previous work, is still satisfied with this higher dataset sustaining the implementation of MLST to assist serological classification as a complementary approach. Bayesian phylogenetic analysis of concatenated sequences from R7-MLST loci allowed us to resolve taxonomic inconsistencies but also showed that events such as recombination, gene conversion or lateral gene transfer played an important role in the evolution of Leptospira genus. Whole genome sequencing allows us to contribute with suitable epidemiologic information useful to apply in the design of control strategies and also in diagnostic methods for this illness. Copyright © 2017 Elsevier B.V. All rights reserved.
Generalized extreme gust wind speeds distributions
Cheng, E.; Yeung, C.
2002-01-01
Since summer 1996, the US wind engineers are using the extreme gust (or 3-s gust) as the basic wind speed to quantify the destruction of extreme winds. In order to better understand these destructive wind forces, it is important to know the appropriate representations of these extreme gust wind speeds. Therefore, the purpose of this study is to determine the most suitable extreme value distributions for the annual extreme gust wind speeds recorded in large selected areas. To achieve this objective, we are using the generalized Pareto distribution as the diagnostic tool for determining the types of extreme gust wind speed distributions. The three-parameter generalized extreme value distribution function is, thus, reduced to either Type I Gumbel, Type II Frechet or Type III reverse Weibull distribution function for the annual extreme gust wind speeds recorded at a specific site.With the considerations of the quality and homogeneity of gust wind data collected at more than 750 weather stations throughout the United States, annual extreme gust wind speeds at selected 143 stations in the contiguous United States were used in the study. ?? 2002 Elsevier Science Ltd. All rights reserved.
Stability study: Transparent conducting oxides in chemically reactive plasmas
NASA Astrophysics Data System (ADS)
Manjunatha, Krishna Nama; Paul, Shashi
2017-12-01
Effect of plasma treatment on transparent conductive oxides (TCOs) including indium-doped tin oxide (ITO), fluorine-doped tin oxide (FTO) and aluminium-doped zinc oxide (AZO) are discussed. Stability of electrical and optical properties of TCOs, when exposed to plasma species generated from gases such as hydrogen and silane, are studied extensively. ITO and FTO thin films are unstable and reduce to their counterparts such as Indium and Tin when subjected to plasma. On the other hand, AZO is not only stable but also shows superior electrical and optical properties. The stability of AZO makes it suitable for electronic applications, such as solar cells and transistors that are fabricated under plasma environment. TCOs exposed to plasma with different fabrication parameters are used in the fabrication of silicon nanowire solar cells. The performance of solar cells, which is mired by the plasma, fabricated on ITO and FTO is discussed with respect to plasma exposure parameters while showing the advantages of using chemically stable AZO as an ideal TCO for solar cells. Additionally, in-situ diagnostic tool (optical emission spectroscopy) is used to monitor the deposition process and damage caused to TCOs.
Design and synthesis of multiple antigenic peptides and their application for dengue diagnosis.
Rai, Reeta; Dubey, Sameer; Santosh, K V; Biswas, Ashutosh; Mehrotra, Vinit; Rao, D N
2017-09-01
Major difficulty in development of dengue diagnostics is availability of suitable antigens. To overcome this, we made an attempt to develop a peptide based diagnosis which offers significant advantage over other methods. With the help of in silico methods, two epitopes were selected from envelope protein and three from NS1 protein of dengue virus. These were synthesized in combination as three multiple antigenic peptides (MAPs). We have tested 157 dengue positive sera confirmed for NS1 antigen. MAP1 showed 96.81% sera positive for IgM and 68.15% positive for IgG. MAP2 detected 94.90% IgM and 59.23% IgG positive sera. MAP3 also detected 96.17% IgM and 59.87% IgG positive sera. To the best of our knowledge this is the first study describing the use of synthetic multiple antigenic peptides for the diagnosis of dengue infection. This study describes MAPs as a promising tool for the use in serodiagnosis of dengue. Copyright © 2017 International Alliance for Biological Standardization. Published by Elsevier Ltd. All rights reserved.
Towards a Better Understanding of Complex Disease: Identifying Endotypes of Childhood Asthma
Complex disease, where the diagnostic criteria cannot distinguish among differing etiologies, is often difficult to diagnose, treat and study due to the inability to classify individuals into suitable subtypes of the disease. Here, we aim to use and compare a combination of met...
USDA-ARS?s Scientific Manuscript database
A new molecular diagnostic method was developed for quantitative detection of “Candidatus Liberibacter” species associated with citrus Huanglongbing (“Ca. Liberibacter asiaticus”, “Ca. Liberibacter africanus” and “Ca. Liberibacter americanus”) and potato zebra chip disorder (“Ca. Liberibacter solana...
Expert Systems Based Clinical Assessment and Tutorial Project.
ERIC Educational Resources Information Center
Papa, Frank; Shores, Jay
This project at the Texas College of Osteopathic Medicine (Fort Worth) evaluated the use of an artificial-intelligence-derived measure, "Knowledge-Based Inference Tool" (KBIT), as the basis for assessing medical students' diagnostic capabilities and designing instruction to improve diagnostic skills. The instrument was designed to…
Classifying diseases and remedies in ethnomedicine and ethnopharmacology.
Staub, Peter O; Geck, Matthias S; Weckerle, Caroline S; Casu, Laura; Leonti, Marco
2015-11-04
Ethnopharmacology focuses on the understanding of local and indigenous use of medicines and therefore an emic approach is inevitable. Often, however, standard biomedical disease classifications are used to describe and analyse local diseases and remedies. Standard classifications might be a valid tool for cross-cultural comparisons and bioprospecting purposes but are not suitable to understand the local perception of disease and use of remedies. Different standard disease classification systems exist but their suitability for cross-cultural comparisons of ethnomedical data has never been assessed. Depending on the research focus, (I) ethnomedical, (II) cross-cultural, and (III) bioprospecting, we provide suggestions for the use of specific classification systems. We analyse three different standard biomedical classification systems (the International Classification of Diseases (ICD); the Economic Botany Data Collection Standard (EBDCS); and the International Classification of Primary Care (ICPC)), and discuss their value for categorizing diseases of ethnomedical systems and their suitability for cross-cultural research in ethnopharmacology. Moreover, based on the biomedical uses of all approved plant derived biomedical drugs, we propose a biomedical therapy-based classification system as a guide for the discovery of drugs from ethnopharmacological sources. Widely used standards, such as the International Classification of Diseases (ICD) by the WHO and the Economic Botany Data Collection Standard (EBDCS) are either technically challenging due to a categorisation system based on clinical examinations, which are usually not possible during field research (ICD) or lack clear biomedical criteria combining disorders and medical effects in an imprecise and confusing way (EBDCS). The International Classification of Primary Care (ICPC), also accepted by the WHO, has more in common with ethnomedical reality than the ICD or the EBDCS, as the categories are designed according to patient's perceptions and are less influenced by clinical medicine. Since diagnostic tools are not required, medical ethnobotanists and ethnopharmacologists can easily classify reported symptoms and complaints with the ICPC in one of the "chapters" based on 17 body systems, psychological and social problems. Also the biomedical uses of plant-derived drugs are classifiable into 17 broad organ- and therapy-based use-categories but can easily be divided into more specific subcategories. Depending on the research focus (I-III) we propose the following classification systems: I. Ethnomedicine: Ethnomedicine is culture-bound and local classifications have to be understood from an emic perspective. Consequently, the application of prefabricated, "one-size fits all" biomedical classification schemes is of limited value. II. Cross-cultural analysis: The ICPC is a suitable standard that can be applied but modified as required. III. Bioprospecting: We suggest a biomedical therapy-driven classification system with currently 17 use-categories based on biomedical uses of all approved plant derived natural product drugs. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Carlton, Edward W; Cullen, Louise; Than, Martin; Gamble, James; Khattab, Ahmed; Greaves, Kim
2015-01-01
Objective To establish whether a novel accelerated diagnostic protocol (ADP) for suspected acute coronary syndrome (ACS) could successfully identify low-risk patients suitable for discharge after a single high-sensitivity troponin T (hs-cTnT) taken at presentation to the emergency department. We also compared the diagnostic accuracy of this ADP with strategies using initial undetectable hs-cTnT. Methods This prospective observational study evaluated the ability of the Triage Rule-out Using high-Sensitivity Troponin (TRUST) ADP to identify low-risk patients with suspected ACS. The ADP incorporated a single presentation hs-cTnT of <14 ng/L, a non-ischaemic ECG and a modified Goldman risk score. Diagnostic performance of the ADP was compared with the detection limit cut-offs of hs-cTnT (<5 ng/L and <3 ng/L). The primary end point was fatal/non-fatal acute myocardial infarction (AMI) within 30 days. Results 960 participants were recruited, mean age 58.0 years, 80 (8.3%) had an AMI. The TRUST ADP classified 382 (39.8%) as low-risk with a sensitivity for identifying AMI of 98.8% (95% CI 92.5% to 99.9%). hs-cTnT detection limits (<5 ng/L and <3 ng/L) had a sensitivity of 100% (94.3 to 100) and 100% (94.4 to 100), respectively. The TRUST ADP identified more patients suitable for early discharge at 39.8% vs 29.3% (<5 ng/L) and 7.9% (<3 ng/L) (p<0.001) with a lower false-positive rate for AMI detection; specificity 43.3% (95% CI 42.7% to 43.4%) vs 32.0% (95% CI 31.5% to 32.0%) and 8.6% (95% CI 8.1% to 8.6%), respectively. Conclusions The TRUST ADP, which incorporates structured risk-assessment and a single presentation hs-cTnT blood draw, has potential to allow early discharge in 40% of patients with suspected ACS and has greater clinical utility than undetectable hs-cTnT strategies. Trial registration number ISRCTN No. 21109279. PMID:25691511
ERIC Educational Resources Information Center
Rowe, Laura
2017-01-01
An introductory bioinformatics laboratory experiment focused on protein analysis has been developed that is suitable for undergraduate students in introductory biochemistry courses. The laboratory experiment is designed to be potentially used as a "stand-alone" activity in which students are introduced to basic bioinformatics tools and…
3D FEM Simulation of Flank Wear in Turning
NASA Astrophysics Data System (ADS)
Attanasio, Aldo; Ceretti, Elisabetta; Giardini, Claudio
2011-05-01
This work deals with tool wear simulation. Studying the influence of tool wear on tool life, tool substitution policy and influence on final part quality, surface integrity, cutting forces and power consumption it is important to reduce the global process costs. Adhesion, abrasion, erosion, diffusion, corrosion and fracture are some of the phenomena responsible of the tool wear depending on the selected cutting parameters: cutting velocity, feed rate, depth of cut, …. In some cases these wear mechanisms are described by analytical models as a function of process variables (temperature, pressure and sliding velocity along the cutting surface). These analytical models are suitable to be implemented in FEM codes and they can be utilized to simulate the tool wear. In the present paper a commercial 3D FEM software has been customized to simulate the tool wear during turning operations when cutting AISI 1045 carbon steel with uncoated tungsten carbide tip. The FEM software was improved by means of a suitable subroutine able to modify the tool geometry on the basis of the estimated tool wear as the simulation goes on. Since for the considered couple of tool-workpiece material the main phenomena generating wear are the abrasive and the diffusive ones, the tool wear model implemented into the subroutine was obtained as combination between the Usui's and the Takeyama and Murata's models. A comparison between experimental and simulated flank tool wear curves is reported demonstrating that it is possible to simulate the tool wear development.
Automating the application of smart materials for protein crystallization
DOE Office of Scientific and Technical Information (OSTI.GOV)
Khurshid, Sahir; Govada, Lata; EL-Sharif, Hazim F.
2015-03-01
The first semi-liquid, non-protein nucleating agent for automated protein crystallization trials is described. This ‘smart material’ is demonstrated to induce crystal growth and will provide a simple, cost-effective tool for scientists in academia and industry. The fabrication and validation of the first semi-liquid nonprotein nucleating agent to be administered automatically to crystallization trials is reported. This research builds upon prior demonstration of the suitability of molecularly imprinted polymers (MIPs; known as ‘smart materials’) for inducing protein crystal growth. Modified MIPs of altered texture suitable for high-throughput trials are demonstrated to improve crystal quality and to increase the probability of successmore » when screening for suitable crystallization conditions. The application of these materials is simple, time-efficient and will provide a potent tool for structural biologists embarking on crystallization trials.« less
Kao, S Y; Chou, J; Lo, J; Yang, J; Chou, A P; Joe, C J; Chang, R C
1999-04-01
Roentgenographic examination has long been a useful diagnostic tool for temporo-mandibular joint (TMJ) disease. The methods include TMJ tomography, panoramic radiography and computerized tomography (CT) scan with or without injection of contrast media. Recently, three-dimensional CT (3D-CT), reconstructed from the two-dimensional image of a CT scan to simulate the soft tissue or bony structure of the real target, was proposed. In this report, a case of TMJ ankylosis due to traumatic injury is presented. 3D-CT was employed as one of the presurgical roentgenographic diagnostic tools. The conventional radiographic examination including panoramic radiography and tomography showed lesions in both sides of the mandible. CT scanning further suggested that the right-sided lesion was more severe than that on the left. With 3D-CT image reconstruction the size and extent of the lesions were clearly observable. The decision was made to proceed with an initial surgical approach on the right side. With condylectomy and condylar replacement using an autogenous costochondral graft on the right side, the range of mouth opening improved significantly. In this case report, 3D-CT demonstrates its advantages as a tool for the correct and precise diagnosis of TMJ ankylosis.
Circulating microRNA-based screening tool for breast cancer
Boukerroucha, Meriem; Fasquelle, Corinne; Thiry, Jérôme; Bovy, Nicolas; Struman, Ingrid; Geurts, Pierre; Collignon, Joëlle; Schroeder, Hélène; Kridelka, Frédéric; Lifrange, Eric; Jossa, Véronique
2016-01-01
Circulating microRNAs (miRNAs) are increasingly recognized as powerful biomarkers in several pathologies, including breast cancer. Here, their plasmatic levels were measured to be used as an alternative screening procedure to mammography for breast cancer diagnosis. A plasma miRNA profile was determined by RT-qPCR in a cohort of 378 women. A diagnostic model was designed based on the expression of 8 miRNAs measured first in a profiling cohort composed of 41 primary breast cancers and 45 controls, and further validated in diverse cohorts composed of 108 primary breast cancers, 88 controls, 35 breast cancers in remission, 31 metastatic breast cancers and 30 gynecologic tumors. A receiver operating characteristic curve derived from the 8-miRNA random forest based diagnostic tool exhibited an area under the curve of 0.81. The accuracy of the diagnostic tool remained unchanged considering age and tumor stage. The miRNA signature correctly identified patients with metastatic breast cancer. The use of the classification model on cohorts of patients with breast cancers in remission and with gynecologic cancers yielded prediction distributions similar to that of the control group. Using a multivariate supervised learning method and a set of 8 circulating miRNAs, we designed an accurate, minimally invasive screening tool for breast cancer. PMID:26734993
Confocal microscopy patterns in nonmelanoma skin cancer and clinical applications.
González, S; Sánchez, V; González-Rodríguez, A; Parrado, C; Ullrich, M
2014-06-01
Reflectance confocal microscopy is currently the most promising noninvasive diagnostic tool for studying cutaneous structures between the stratum corneum and the superficial reticular dermis. This tool gives real-time images parallel to the skin surface; the microscopic resolution is similar to that of conventional histology. Numerous studies have identified the main confocal features of various inflammatory skin diseases and tumors, demonstrating the good correlation of these features with certain dermatoscopic patterns and histologic findings. Confocal patterns and diagnostic algorithms have been shown to have high sensitivity and specificity in melanoma and nonmelanoma skin cancer. Possible present and future applications of this noninvasive technology are wide ranging and reach beyond its use in noninvasive diagnosis. This tool can also be used, for example, to evaluate dynamic skin processes that occur after UV exposure or to assess tumor response to noninvasive treatments such as photodynamic therapy. We explain the characteristic confocal features found in the main nonmelanoma skin tumors and discuss possible applications for this novel diagnostic technique in routine dermatology practice. Copyright © 2012 Elsevier España, S.L. and AEDV. All rights reserved.
[Diagnostic tools for canine parvovirus infection].
Proksch, A L; Hartmann, K
2015-01-01
Canine parvovirus (CPV) infection is one of the most important and common infectious diseases in dogs, in particular affecting young puppies when maternal antibodies have waned and vaccine-induced antibodies have not yet developed. The mortality rate remains high. Therefore, a rapid and safe diagnostic tool is essential to diagnose the disease to 1) provide intensive care treatment and 2) to identify virus-shedding animals and thus prevent virus spread. Whilst the detection of antibodies against CPV is considered unsuitable to diagnose the disease, there are several different methods to directly detect complete virus, virus antigen or DNA. Additionally, to test in commercial laboratories, rapid in-house tests based on ELISA are available worldwide. The specificity of the ELISA rapid in-house tests is reported to be excellent. However, results on sensitivity vary and high numbers of false-negative results are commonly reported, which potentially leads to misdiagnosis. Polymerase chain reaction (PCR) is a very sensitive and specific diagnostic tool. It also provides the opportunity to differentiate vaccine strains from natural infection when sequencing is performed after PCR.
MicroRNAs in osteosarcoma: diagnostic and therapeutic aspects.
Miao, Jinglei; Wu, Song; Peng, Zhi; Tania, Mousumi; Zhang, Chaoyue
2013-08-01
MicroRNAs (miRNAs) are small RNA molecules, which can interfere with the expression of several genes and act as gene regulator. miRNAs have been proved as a successful diagnostic and therapeutic tool in several cancers. In this review, the differential expression of miRNAs in osteosarcoma and their possibility to be used as diagnostic and therapeutic tools have been discussed. Osteosarcoma is the most common primary bone tumor that mainly affects children and adolescents. The current treatment of osteosarcoma remains difficult, and osteosarcoma causes many deaths because of its complex pathogenesis and resistance to conventional treatments. Several studies demonstrated that the differential expression patterns of miRNAs are a promising tool for the diagnosis and treatment of osteosarcoma. Although some aspect of the mechanism of action of miRNAs in controlling osteosarcoma has been identified (e.g., targeting the Notch signaling pathway), it is far beyond to the clear understanding of miRNA targets in osteosarcoma. Identification of the specific target of miRNAs may aid molecular targets for drug development and future relief of osteosarcoma.
Advanced Optical Diagnostic Methods for Describing Fuel Injection and Combustion Flowfield Phenomena
NASA Technical Reports Server (NTRS)
Locke, Randy J.; Hicks, Yolanda R.; Anderson, Robert C.
2004-01-01
Over the past decade advanced optical diagnostic techniques have evolved and matured to a point where they are now widely applied in the interrogation of high pressure combusting flows. At NASA Glenn Research Center (GRC), imaging techniques have been used successfully in on-going work to develop the next generation of commercial aircraft gas turbine combustors. This work has centered on providing a means by which researchers and designers can obtain direct visual observation and measurements of the fuel injection/mixing/combustion processes and combustor flowfield in two- and three-dimensional views at actual operational conditions. Obtaining a thorough understanding of the chemical and physical processes at the extreme operating conditions of the next generation of combustors is critical to reducing emissions and increasing fuel efficiency. To accomplish this and other tasks, the diagnostic team at GRC has designed and constructed optically accessible, high pressurer high temperature flame tubes and sectar rigs capable of optically probing the 20-60 atm flowfields of these aero-combustors. Among the techniques employed at GRC are planar laser-induced fluorescence (PLIF) for imaging molecular species as well as liquid and gaseous fuel; planar light scattering (PLS) for imaging fuel sprays and droplets; and spontaneous Raman scattering for species and temperature measurement. Using these techniques, optical measurements never before possible have been made in the actual environments of liquid fueled gas turbines. 2-D mapping of such parameters as species (e.g. OH-, NO and kerosene-based jet fuel) distribution, injector spray angle, and fuel/air distribution are just some of the measurements that are now routinely made. Optical imaging has also provided prompt feedback to researchers regarding the effects of changes in the fuel injector configuration on both combustor performance and flowfield character. Several injector design modifications and improvements have resulted from this feedback. Alternate diagnostic methods are constantly being evaluated as to their suitability as a diagnostic tool in these environments. A new method currently under examination is background oriented Schlieren (BOS) for examining the fuel/air mixing processes. While ratioing the Stokes and anti-Stokes nitrogen lines obtained from spontaneous Raman is being refined for temperature measurement. While the primary focus of the GRC diagnostic work remains optical species measurement and flow stream characterization, an increased emphasis has been placed on our involvement in flame code validation efforts. A functional combustor code should shorten and streamline future combustor design. Quantitative measurements of flow parameters such as temperature, species concentration, drop size and velocity using such methods as Raman and phase Doppler anemometry will provide data necessary in this effort.
Rampling, Jeremy; Mitchell, Alex J; Von Oertzen, Tim; Docker, James; Jackson, Jemima; Cock, Hannah; Agrawal, Niruj
2012-10-01
Depression is an important but underdiagnosed complication of epilepsy. This study compares potentially suitable screening tools head-to-head. We enrolled 266 attendees with a confirmed diagnosis of epilepsy at a specialized neurologic epilepsy service in London and compared verbal self-report and visual analog (VAS) screening methods for depression. These included two generic depression scales (Hospital Anxiety and Depression Scale [HADS], Beck Depression Inventory II [BDI-II]), one epilepsy specific scale (Neurological Disorders Depression Inventory for Epilepsy [NDDI-E]) and one new visual-analog scale (Emotional Thermometers [ET]). We used Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition (DSM-IV) criteria for major depression and International Classification of Diseases, Tenth Revision (ICD-10) criteria for depressive episode as the reference standard. Against ICD-10-defined depression the most accurate scales by receiver operating characteristic (ROC) curve area were HADS Total (HADS-T, 0.924), BDI-II (0.898) and NDDI-E (0.897). New visual-analog methods had similar accuracy measured either in combination or individually. Although no test performed well in a case-finding role, several performed well as a rule-out initial step, owing to high negative predictive value and specificity. In this role, the optimal performing conventional tools were the HADS depression subsscale (HADS-D) and the NDDI-E and the optimal single VAS were the depression thermometer (DepT) and the distress thermometer (DT). Against DSM-IV- defined major depression, results were similar with optimal performance by the HADS-T, BDI-II, and NDDI-E, but here the anxiety thermometer (AnxT) as well as DepT and DT also offered good performance. Given that no test performed well in a case-finding role, we suggest that these tests are used as an initial first step to rule out patients who are unlikely to have depression. We suggest that the six-item NDDI-E or seven-item HADS-D should be considered if a conventional scale is preferred and that the revised ET4 be considered if a visual-analog method is required. Follow-up examination and intervention, where indicated, are necessary in all those who screen positive on any measure as these are not intended as diagnostic tools. Wiley Periodicals, Inc. © 2012 International League Against Epilepsy.
Eating Behaviors and Obesity in African American and Caucasian Women
2010-08-16
Disorder Diagnostic Scale [23] is a 22-item scale that is useful as a screening tool for Anorexia Nervosa , Bulimia Nervosa , and Binge Eating Disorder...Agreement between eating disorder diagnoses from the Eating Disorder Diagnostic Scale and those by clinical interview is high: 99% for Anorexia , 96...Diagnostic Scale revealed that only 24% of the total sample met criteria for Bulimia Nervosa or Binge Eating Disordered behavior (sub- or threshold
Moore, Helen J; Nixon, Catherine; Tariq, Anisah; Emery, Jon; Hamilton, Willie; Hoare, Zoë; Kershenbaum, Anne; Neal, Richard D; Ukoumunne, Obioha C; Usher-Smith, Juliet; Walter, Fiona M; Whyte, Sophie; Rubin, Greg
2016-04-04
For most cancers, only a minority of patients have symptoms meeting the National Institute for Health and Clinical Excellence guidance for urgent referral. For gastro-oesophageal cancers, the 'alarm' symptoms of dysphagia and weight loss are reported by only 32 and 8 % of patients, respectively, and their presence correlates with advanced-stage disease. Electronic clinical decision-support tools that integrate with clinical computer systems have been developed for general practice, although uncertainty remains concerning their effectiveness. The objectives of this trial are to optimise the intervention and establish the acceptability of both the intervention and randomisation, confirm the suitability and selection of outcome measures, finalise the design for the phase III definitive trial, and obtain preliminary estimates of the intervention effect. This is a two-arm, multi-centre, cluster-randomised, controlled phase II trial design, which will extend over a 16-month period, across 60 general practices within the North East and North Cumbria and the Eastern Local Clinical Research Network areas. Practices will be randomised to receive either the intervention (the electronic clinical decision-support tool) or to act as a control (usual care). From these practices, we will recruit 3000 adults who meet the trial eligibility criteria and present to their GP with symptoms suggestive of gastro-oesophageal cancer. The main measures are the process data, which include the practitioner outcomes, service outcomes, diagnostic intervals, health economic outcomes, and patient outcomes. One-on-one interviews in a sub-sample of 30 patient-GP dyads will be undertaken to understand the impact of the use or non-use of the electronic clinical decision-support tool in the consultation. A further 10-15 GPs will be interviewed to identify and gain an understanding of the facilitators and constraints influencing implementation of the electronic clinical decision-support tool in practice. We aim to generate new knowledge on the process measures regarding the use of electronic clinical decision-support tools in primary care in general and to inform a subsequent definitive phase III trial. Preliminary data on the impact of the support tool on resource utilisation and health care costs will also be collected. ISRCTN Registry, ISRCTN12595588 .
29 CFR 1926.959 - Lineman's body belts, safety straps, and lanyards.
Code of Federal Regulations, 2010 CFR
2010-07-01
... tool pockets. On shifting D belts, this measurement for pocket tabs shall be taken when the D ring section is centered. (3) A maximum of four (4) tool loops shall be so situated on the body belt that four... of tool loops, and any other attachments. (4) Suitable copper, steel, or equivalent liners shall be...
Management and treatment of mucosal melanoma of the genital tract.
Vaccari, Sabina; Barisani, Alessia; Dika, Emi; Fanti, Pier A; DE Iaco, Pierandrea; Gurioli, Carlotta; Tosti, Giulio
2017-06-01
The melanoma of the genital mucosa is a rare melanocytic neoplasm that affects both sexes. The diagnosis is often delayed; videodermatoscopy may represent a useful diagnostic tool. The treatment is complex and multidisciplinary. We report the main diagnostic features and therapeutic approaches for mucosal melanoma of the genital tract.
Dogs have been studied for many years as a medical diagnostic tool to detect a pre-clinical disease state by sniffing emissions directly from a human or an in vitro biological sample. Some of the studies report high sensitivity and specificity in blinded case-control studies. How...
Exploring Undergraduates' Understanding of Photosynthesis Using Diagnostic Question Clusters
ERIC Educational Resources Information Center
Parker, Joyce M.; Anderson, Charles W.; Heidemann, Merle; Merrill, John; Merritt, Brett; Richmond, Gail; Urban-Lurain, Mark
2012-01-01
We present a diagnostic question cluster (DQC) that assesses undergraduates' thinking about photosynthesis. This assessment tool is not designed to identify individual misconceptions. Rather, it is focused on students' abilities to apply basic concepts about photosynthesis by reasoning with a coordinated set of practices based on a few scientific…
Terahertz otoscope and potential for diagnosing otitis media
Ji, Young Bin; Moon, In-Seok; Bark, Hyeon Sang; Kim, Sang Hoon; Park, Dong Woo; Noh, Sam Kyu; Huh, Yong-Min; Suh, Jin-Seok; Oh, Seung Jae; Jeon, Tae-In
2016-01-01
We designed and fabricated a novel terahertz (THz) otoscope to help physicians to diagnose otitis media (OM) with both THz diagnostics and conventional optical diagnostics. We verified the potential of this tool for diagnosing OM using mouse skin tissue and a human tympanic membrane samples prior to clinical application. PMID:27446647
DIAGNOSTIC STUDY ON FINE PARTICULATE MATTER PREDICTIONS OF CMAQ IN THE SOUTHEASTERN U.S.
In this study, the authors use the process analysis tool embedded in CMAQ to examine major processes that govern the fate of key pollutants, identify the most influential processes that contribute to model errors, and guide the diagnostic and sensitivity studies aimed at improvin...
Computer Forensics Education - the Open Source Approach
NASA Astrophysics Data System (ADS)
Huebner, Ewa; Bem, Derek; Cheung, Hon
In this chapter we discuss the application of the open source software tools in computer forensics education at tertiary level. We argue that open source tools are more suitable than commercial tools, as they provide the opportunity for students to gain in-depth understanding and appreciation of the computer forensic process as opposed to familiarity with one software product, however complex and multi-functional. With the access to all source programs the students become more than just the consumers of the tools as future forensic investigators. They can also examine the code, understand the relationship between the binary images and relevant data structures, and in the process gain necessary background to become the future creators of new and improved forensic software tools. As a case study we present an advanced subject, Computer Forensics Workshop, which we designed for the Bachelor's degree in computer science at the University of Western Sydney. We based all laboratory work and the main take-home project in this subject on open source software tools. We found that without exception more than one suitable tool can be found to cover each topic in the curriculum adequately. We argue that this approach prepares students better for forensic field work, as they gain confidence to use a variety of tools, not just a single product they are familiar with.
Quantifying Solar Cell Cracks in Photovoltaic Modules by Electroluminescence Imaging
DOE Office of Scientific and Technical Information (OSTI.GOV)
Spataru, Sergiu; Hacke, Peter; Sera, Dezso
2015-06-14
This article proposes a method for quantifying the percentage of partially and totally disconnected solar cell cracks by analyzing electroluminescence images of the photovoltaic module taken under high- and low-current forward bias. The method is based on the analysis of the module's electroluminescence intensity distribution, applied at module and cell level. These concepts are demonstrated on a crystalline silicon photovoltaic module that was subjected to several rounds of mechanical loading and humidity-freeze cycling, causing increasing levels of solar cell cracks. The proposed method can be used as a diagnostic tool to rate cell damage or quality of modules after transportation.more » Moreover, the method can be automated and used in quality control for module manufacturers, installers, or as a diagnostic tool by plant operators and diagnostic service providers.« less
HIDRA-MAT: A Material Analysis Tool for Fusion Devices
NASA Astrophysics Data System (ADS)
Andruczyk, Daniel; Rizkallah, Rabel; Bedoya, Felipe; Kapat, Aveek; Schamis, Hanna; Allain, Jean Paul
2017-10-01
The former WEGA stellarator which is now operating as HIDRA at the University of Illinois will be almost exclusively used to study the intimate relationship between the plasma interacting with surfaces of different materials. A Material Analysis Tool (HIDRA-MAT) is being designed and will be built based on the successful Material Analysis and Particle Probe (MAPP) which is currently used on NSTX-U at PPPL. This will be an in-situ material diagnostic probe, meaning that all analysis can be done without breaking vacuum. This allows surface changes to be studied in real-time. HIDRA-MAT will consist of several in-situ diagnostics including Langmuir probes (LP), Thermal Desorption Spectroscopy (TDS), X-ray Photo Spectroscopy (XPS) and Ion Scattering Spectroscopy (ISS). This presentation will outline the HIDRA-MAT diagnostic and initial design, as well as its integration into the HIDRA system.
A peptide derivatized cellulosic aerogel from cotton as a point of care diagnostic protease sensor
USDA-ARS?s Scientific Manuscript database
Lightweight aerogels are highly porous with usually very small pore size making them suitable for a variety of potential applications as sensors including deformation strain, humidity, organic vapors, thermal, and optical sensing properties. However, little has been reported on their use as biosenso...
Photovoltaic test and demonstration project for the National Photovoltaic Conversion program
NASA Technical Reports Server (NTRS)
Deyo, J. N.
1975-01-01
Proposed are photovoltaic system tests and demonstrations covering a wide range of applications in order to develop low cost photovoltaic cells suitable for terrestrial applications. Program objectives are: (1) tests and model system demonstrations; (2) device performance and diagnostics; and (3) endurance of solar cell modules and arrays.
Designing Real-time Decision Support for Trauma Resuscitations
Yadav, Kabir; Chamberlain, James M.; Lewis, Vicki R.; Abts, Natalie; Chawla, Shawn; Hernandez, Angie; Johnson, Justin; Tuveson, Genevieve; Burd, Randall S.
2016-01-01
Background Use of electronic clinical decision support (eCDS) has been recommended to improve implementation of clinical decision rules. Many eCDS tools, however, are designed and implemented without taking into account the context in which clinical work is performed. Implementation of the pediatric traumatic brain injury (TBI) clinical decision rule at one Level I pediatric emergency department includes an electronic questionnaire triggered when ordering a head computed tomography using computerized physician order entry (CPOE). Providers use this CPOE tool in less than 20% of trauma resuscitation cases. A human factors engineering approach could identify the implementation barriers that are limiting the use of this tool. Objectives The objective was to design a pediatric TBI eCDS tool for trauma resuscitation using a human factors approach. The hypothesis was that clinical experts will rate a usability-enhanced eCDS tool better than the existing CPOE tool for user interface design and suitability for clinical use. Methods This mixed-methods study followed usability evaluation principles. Pediatric emergency physicians were surveyed to identify barriers to using the existing eCDS tool. Using standard trauma resuscitation protocols, a hierarchical task analysis of pediatric TBI evaluation was developed. Five clinical experts, all board-certified pediatric emergency medicine faculty members, then iteratively modified the hierarchical task analysis until reaching consensus. The software team developed a prototype eCDS display using the hierarchical task analysis. Three human factors engineers provided feedback on the prototype through a heuristic evaluation, and the software team refined the eCDS tool using a rapid prototyping process. The eCDS tool then underwent iterative usability evaluations by the five clinical experts using video review of 50 trauma resuscitation cases. A final eCDS tool was created based on their feedback, with content analysis of the evaluations performed to ensure all concerns were identified and addressed. Results Among 26 EPs (76% response rate), the main barriers to using the existing tool were that the information displayed is redundant and does not fit clinical workflow. After the prototype eCDS tool was developed based on the trauma resuscitation hierarchical task analysis, the human factors engineers rated it to be better than the CPOE tool for nine of 10 standard user interface design heuristics on a three-point scale. The eCDS tool was also rated better for clinical use on the same scale, in 84% of 50 expert–video pairs, and was rated equivalent in the remainder. Clinical experts also rated barriers to use of the eCDS tool as being low. Conclusions An eCDS tool for diagnostic imaging designed using human factors engineering methods has improved perceived usability among pediatric emergency physicians. PMID:26300010
Investigation of Gear and Bearing Fatigue Damage Using Debris Particle Distributions
NASA Technical Reports Server (NTRS)
Dempsey, Paula J.; Lewicki, David G.; Decker, Harry J.
2004-01-01
A diagnostic tool was developed for detecting fatigue damage to spur gears, spiral bevel gears, and rolling element bearings. This diagnostic tool was developed and evaluated experimentally by collecting oil debris data from fatigue tests performed in the NASA Glenn Spur Gear Fatigue Rig, Spiral Bevel Gear Test Facility, and the 500hp Helicopter Transmission Test Stand. During each test, data from an online, in-line, inductance type oil debris sensor was monitored and recorded for the occurrence of pitting damage. Results indicate oil debris alone cannot discriminate between bearing and gear fatigue damage.
Multigrid Techniques for Highly Indefinite Equations
NASA Technical Reports Server (NTRS)
Shapira, Yair
1996-01-01
A multigrid method for the solution of finite difference approximations of elliptic PDE's is introduced. A parallelizable version of it, suitable for two and multi level analysis, is also defined, and serves as a theoretical tool for deriving a suitable implementation for the main version. For indefinite Helmholtz equations, this analysis provides a suitable mesh size for the coarsest grid used. Numerical experiments show that the method is applicable to diffusion equations with discontinuous coefficients and highly indefinite Helmholtz equations.