Spread Spectrum Receiver Electromagnetic Interference (EMI) Test Guide
NASA Technical Reports Server (NTRS)
Wheeler, Mark L.
1998-01-01
This program consisted of: (1) a study to define appropriate EMI test guidelines and test methods for direct sequence (DS) spread spectrum receivers; and (2) preparation of a written test guide to document the recommended test methods. The scope of this test guide includes: (1) a discussion of generic DS receiver performance characteristics; (2) a summary of S-band TDRSS receiver operation; (3) a discussion of DS receiver EMI susceptibility mechanisms and characteristics; (4) a summary of military standard test guidelines; (5) recommended test approach and methods; and (6) general conclusions and recommendations for future studies in the area of spread spectrum receiver testing.
A Guidance Document for Kentucky's Oil and Gas Operations
DOE Office of Scientific and Technical Information (OSTI.GOV)
None, None
1998-11-10
This technical report is a summary of the progress made for "A Guidance Document for Kentucky's Oil and Gas Operators". During this quarter, the document received continued review and editing in an elec-tronic format to satisfy the United States Department of Energy (DOE). Comments received from oil and gas operators reviewing this document prompted contact to be made with the United States Environmental Protection Agency (USEPA) to develop an addendum section to provide better explanation of USEPA requirements for Class II injection wells in Kentucky.
NASA Technical Reports Server (NTRS)
1975-01-01
Overall program activities and the technology developed to accomplish lunar exploration are discussed. A summary of the flights conducted over an 11-year period is presented along with specific aspects of the overall program, including lunar science, vehicle development and performance, lunar module development program, spacecraft development testing, flight crew summary, mission operations, biomedical data, spacecraft manufacturing and testing, launch site facilities, equipment, and prelaunch operations, and the lunar receiving laboratory. Appendixes provide data on each of the Apollo missions, mission type designations, spacecraft weights, records achieved by Apollo crewmen, vehicle histories, and a listing of anomalous hardware conditions noted during each flight beginning with Apollo 4.
78 FR 45287 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2013-07-26
... CFR Sec. 91.225(a), (b), and (d), Automatic Dependent Surveillance-Broadcast (ADS-B) Out, on all... Extended Squitter (ES) ADS-B and Traffic information Service-Broadcast (TIS-B) operating on the frequency of 1090 Megahertz (MHz) and Universal Access Transceiver (UAT) ADS-B equipment operating on the...
78 FR 29808 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-21
... signing the comment for an association, business, labor union, etc.). You may review DOT's complete... would allow Northrop Grumman Systems Corporation to operate a BE-1900 (a type rated aircraft requiring...
75 FR 14483 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2010-03-25
... sending the comment (or signing the comment for an association, business, labor union, etc.). You may..., 1800, 1900, 2000 and 2100 hours. The proposed exemption would permit Air Canada to continue operating...
78 FR 4190 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2013-01-18
... Lines' 737-800 fleet, a placard was placed on the flight deck prohibiting use of WiFi devices from the... using the existing aircraft WiFi connection during the operational demonstration period of the research...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-09-10
... Incidental to Construction and Operation of a Liquefied Natural Gas Deepwater Port in the Gulf of Mexico... Incidental to Construction and Operation of a Liquefied Natural Gas Deepwater Port in the Gulf of Mexico...), Commerce. ACTION: Proposed rule; request for comments. SUMMARY: NMFS has received a request from Port...
78 FR 29122 - Proposed Collection; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-17
... information technology. DATES: Consideration will be given to all comments received by July 16, 2013.... SUPPLEMENTARY INFORMATION: Summary of Information Collection Respondents are military contractors requiring... Headquarter Air Force Special Operations Command Special Activities announces a proposed public information...
77 FR 64581 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-22
... operate their turbo-jet powered Comp-Let TST-14 glider without completing within the preceding 12 calendar..., complete a pilot-in-command proficiency check in the turbo-jet powered Comp-Let TST-14 glider. [FR Doc...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-02-28
... (EPA). ACTION: Notice. SUMMARY: This notice announces that, on December 30, 2010, pursuant to title V of the Clean Air Act, EPA issued a title V Permit to Operate (title V permit) to the Mille Lacs Band... permits, which ended April 5, 2010, EPA received comments on the draft title V permit, and revised the...
76 FR 63342 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2011-10-12
...-1039. Petitioner: PHI, Inc. Section of 14 CFR Affected: Sec. 91.9(a). Description of Relief Sought: PHI, Inc. (PHI), requests an exemption from 91.9(a) to allow PHI to operate S-92A helicopters in accordance...
77 FR 29317 - Fiscal Year 2012 Draft Work Plan
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-17
..., the Commission determines its own basic operating principles and funding criteria on an annual federal fiscal year (October 1 to September 30) basis. The Commission outlines these priorities and funding... 2012 Appropriations Summary The Denali Commission has historically received several federal funding...
75 FR 19672 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-15
... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration [Summary Notice No. PE-2010-15] Petition for Exemption; Summary of Petition Received AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of petition for exemption received. SUMMARY: This notice contains a summary petition...
Diaphragm and Lung Ultrasound to Predict Weaning Outcome: Systematic Review and Meta-Analysis.
Llamas-Álvarez, Ana M; Tenza-Lozano, Eva M; Latour-Pérez, Jaime
2017-12-01
Deciding the optimal timing for extubation in patients who are mechanically ventilated can be challenging, and traditional weaning predictor tools are not very accurate. The aim of this systematic review and meta-analysis was to assess the accuracy of lung and diaphragm ultrasound for predicting weaning outcomes in critically ill adults. MEDLINE, the Cochrane Library, Web of Science, Scopus, LILACS, Teseo, Tesis Doctorales en Red, and OpenGrey were searched, and the bibliographies of relevant studies were reviewed. Two researchers independently selected studies that met the inclusion criteria and assessed study quality in accordance with the Quality Assessment of Diagnostic Accuracy Studies-2 tool. The summary receiver-operating characteristic curve and pooled diagnostic OR (DOR) were estimated by using a bivariate random effects analysis. Sources of heterogeneity were explored by using predefined subgroup analyses and bivariate meta-regression. Nineteen studies involving 1,071 people were included in the study. For diaphragm thickening fraction, the area under the summary receiver-operating characteristic curve was 0.87, and DOR was 21 (95% CI, 11-40). Regarding diaphragmatic excursion, pooled sensitivity was 75% (95% CI, 65-85); pooled specificity, 75% (95% CI, 60-85); and DOR, 10 (95% CI, 4-24). For lung ultrasound, the area under the summary receiver-operating characteristic curve was 0.77, and DOR was 38 (95% CI, 7-198). Based on bivariate meta-regression analysis, a significantly higher specificity for diaphragm thickening fraction and higher sensitivity for diaphragmatic excursion was detected in studies with applicability concerns. Lung and diaphragm ultrasound can help predict weaning outcome, but its accuracy may vary depending on the patient subpopulation. Copyright © 2017 American College of Chest Physicians. Published by Elsevier Inc. All rights reserved.
78 FR 7477 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2013-02-01
... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration [Summary Notice No. PE-2012-56] Petition for Exemption; Summary of Petition Received AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of petition for exemption received. SUMMARY: This notice contains a summary of a petition...
76 FR 24560 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-02
... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration [Summary Notice No. PE-2011-18] Petition for Exemption; Summary of Petition Received AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of petition for exemption received. SUMMARY: This notice contains a summary of a petition...
78 FR 60996 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2013-10-02
... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration [Summary Notice No. PE-2013-48] Petition for Exemption; Summary of Petition Received AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of petition for exemption received. SUMMARY: This notice contains a summary of a petition...
78 FR 59753 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-27
... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration [Summary Notice No. PE-2013-46] Petition for Exemption; Summary of Petition Received AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of petition for exemption received. SUMMARY: This notice contains a summary of a petition...
78 FR 3068 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2013-01-15
... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration [Summary Notice No. PE-2012-54] Petition for Exemption; Summary of Petition Received AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of petition for exemption received. SUMMARY: This notice contains a summary of a petition...
77 FR 71864 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2012-12-04
... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration [Summary Notice No. PE-2012-46] Petition for Exemption; Summary of Petition Received AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of petition for exemption received. SUMMARY: This notice contains a summary of a petition...
76 FR 26335 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-06
... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration [Summary Notice No. PE-2011-19] Petition for Exemption; Summary of Petition Received AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of petition for exemption received. SUMMARY: This notice contains a summary of a petition...
77 FR 54650 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2012-09-05
... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration [Summary Notice No. PE-2012-34] Petition for Exemption; Summary of Petition Received AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of petition for exemption received. SUMMARY: This notice contains a summary of a petition...
78 FR 46672 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2013-08-01
... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration [Summary Notice No. PE-2013-30] Petition for Exemption; Summary of Petition Received AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of petition for exemption received. SUMMARY: This notice contains a summary of a petition...
75 FR 15771 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2010-03-30
... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration [Summary Notice No. PE-2010-08] Petition for Exemption; Summary of Petition Received AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of petition for exemption received. SUMMARY: This notice contains a summary of a petition...
77 FR 71865 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2012-12-04
... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration [Summary Notice No. PE-2012-51] Petition for Exemption; Summary of Petition Received AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of petition for exemption received. SUMMARY: This notice contains a summary of a petition...
75 FR 80107 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2010-12-21
... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration [Summary Notice No. PE-2010-60] Petition for Exemption; Summary of Petition Received AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of petition for exemption received. SUMMARY: This notice contains a summary of a petition...
76 FR 20806 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2011-04-13
... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration [Summary Notice No. PE-2011-16] Petition for Exemption; Summary of Petition Received AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of petition for exemption received. SUMMARY: This notice contains a summary of a petition...
78 FR 53185 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2013-08-28
... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration [Summary Notice No. PE-2013-37] Petition for Exemption; Summary of Petition Received AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of petition for exemption received. SUMMARY: This notice contains a summary of a petition...
76 FR 65772 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2011-10-24
... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration [Summary Notice No. PE-2011-48] Petition for Exemption; Summary of Petition Received AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of petition for exemption received. SUMMARY: This notice contains a summary of a petition...
75 FR 60164 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2010-09-29
... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration [Summary Notice No. PE-2010-42] Petition for Exemption; Summary of Petition Received AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of petition for exemption received. SUMMARY: This notice contains a summary of a petition...
76 FR 39975 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-07
... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration [Summary Notice No. PE-2011-29] Petition for Exemption; Summary of Petition Received AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of petition for exemption received. SUMMARY: This notice contains a summary of a petition...
77 FR 13385 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-06
... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration [Summary Notice No. PE-2012-08] Petition for Exemption; Summary of Petition Received AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of petition for exemption received. SUMMARY: This notice contains a summary of a petition...
76 FR 39976 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-07
... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration [Summary Notice No. PE-2011-30] Petition for Exemption; Summary of Petition Received AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of petition for exemption received. SUMMARY: This notice contains a summary of a petition...
75 FR 76068 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2010-12-07
... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration [Summary Notice No. PE-2010-56] Petition for Exemption; Summary of Petition Received AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of petition for exemption received. SUMMARY: This notice contains a summary of a petition...
77 FR 2120 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2012-01-13
... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration [Summary Notice No. PE-2012-02] Petition for Exemption; Summary of Petition Received AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of petition for exemption received. SUMMARY: This notice contains a summary of a petition...
77 FR 54649 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2012-09-05
... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration [Summary Notice No. PE-2012-35] Petition for Exemption; Summary of Petition Received AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of petition for exemption received. SUMMARY: This notice contains a summary of a petition...
78 FR 7851 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2013-02-04
... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration [Summary Notice No. PE-2012-57 ] Petition for Exemption; Summary of Petition Received AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of petition for exemption received. SUMMARY: This notice contains a summary of a petition...
76 FR 14744 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2011-03-17
... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration [Summary Notice No. PE-2011-120] Petition for Exemption; Summary of Petition Received AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of petition for exemption received. SUMMARY: This notice contains a summary of a petition...
75 FR 19459 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-14
... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration [Summary Notice No. PE-2010-13] Petition for Exemption; Summary of Petition Received AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of petition for exemption received. SUMMARY: This notice contains a summary of a petition...
77 FR 71864 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2012-12-04
... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration [Summary Notice No. PE-2012-50] Petition for Exemption; Summary of Petition Received AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of petition for exemption received. SUMMARY: This notice contains a summary of a petition...
76 FR 39976 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-07
... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration [Summary Notice No. PE-2011-32] Petition for Exemption; Summary of Petition Received AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of petition for exemption received. SUMMARY: This notice contains a summary of a petition...
77 FR 71474 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2012-11-30
... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration [Summary Notice No. PE-2012-53] Petition for Exemption; Summary of Petition Received AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of petition for exemption received. SUMMARY: This notice contains a summary of a petition...
75 FR 21388 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-23
... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration [Summary Notice No. PE-2010-14] Petition for Exemption; Summary of Petition Received AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of petition for exemption received. SUMMARY: This notice contains a summary of a petition...
77 FR 13384 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-06
... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration [Summary Notice No. PE-2012-06] Petition for Exemption; Summary of Petition Received AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of petition for exemption received. SUMMARY: This notice contains a summary of a petition...
78 FR 58599 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-24
... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration [Summary Notice No. PE-2013-42] Petition for Exemption; Summary of Petition Received AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of petition for exemption received. SUMMARY: This notice contains a summary of a petition...
75 FR 47882 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-09
... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration [Summary Notice No. PE-2010-34] Petition for Exemption; Summary of Petition Received AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of petition for exemption received. SUMMARY: This notice contains a summary of a petition...
78 FR 53185 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2013-08-28
... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration [Summary Notice No. PE-2013-41] Petition for Exemption; Summary of Petition Received AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of petition for exemption received. SUMMARY: This notice contains a summary of a petition...
75 FR 80106 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2010-12-21
... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration [Summary Notice No. PE-2010-59] Petition for Exemption; Summary of Petition Received AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of petition for exemption received. SUMMARY: This notice contains a summary of a petition...
78 FR 73918 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2013-12-09
... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration [Summary Notice No. PE-2013-58] Petition for Exemption; Summary of Petition Received AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of petition for exemption received. SUMMARY: This notice contains a summary of a petition...
78 FR 21701 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-11
... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration [Summary Notice No. PE-2013-16] Petition for Exemption; Summary of Petition Received AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of petition for exemption received. SUMMARY: This notice contains a summary of a petition...
78 FR 69930 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2013-11-21
... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration [Summary Notice No. PE-2013-56] Petition for Exemption; Summary of Petition Received AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of petition for exemption received. SUMMARY: This notice contains a summary of a petition...
78 FR 67441 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2013-11-12
... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration [Summary Notice No. PE-2013-52] Petition for Exemption; Summary of Petition Received AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of petition for exemption received. SUMMARY: This notice contains a summary of a petition...
76 FR 66351 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2011-10-26
... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration [Summary Notice No. PE-2011-48] Petition for Exemption; Summary of Petition Received AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of petition for exemption received. SUMMARY: This notice contains a summary of a petition...
78 FR 57676 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-19
... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration [Summary Notice No. PE-2013-44] Petition for Exemption; Summary of Petition Received AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of petition for exemption received. SUMMARY: This notice contains a summary of a petition...
75 FR 51164 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-18
... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration [Summary Notice No. PE-2010-35] Petition for Exemption; Summary of Petition Received AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of petition for exemption received. SUMMARY: This notice contains a summary of a petition...
78 FR 60995 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2013-10-02
... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration [Summary Notice No. PE-2013-47] Petition for Exemption; Summary of Petition Received AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of petition for exemption received. SUMMARY: This notice contains a summary of a petition...
78 FR 3068 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2013-01-15
... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration [Summary Notice No. PE-2012-60] Petition for Exemption; Summary of Petition Received AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of petition for exemption received. SUMMARY: This notice contains a summary of a petition...
78 FR 36294 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2013-06-17
... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration [Summary Notice No. PE-2013-25] Petition for Exemption; Summary of Petition Received AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of petition for exemption received. SUMMARY: This notice contains a summary of a petition...
78 FR 46673 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2013-08-01
... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration [Summary Notice No. PE-2013-33] Petition for Exemption; Summary of Petition Received AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of petition for exemption received. SUMMARY: This notice contains a summary of a petition...
78 FR 13746 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2013-02-28
... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration [Summary Notice No. PE-2013-07] Petition for Exemption; Summary of Petition Received AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of petition for exemption received. SUMMARY: This notice contains a summary of a petition...
75 FR 55394 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2010-09-10
... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration [Summary Notice No. PE-2010-40] Petition for Exemption; Summary of Petition Received AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of petition for exemption received. SUMMARY: This notice contains a summary of a petition...
75 FR 19672 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-15
... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration [Summary Notice No. PE-2009-18] Petition for Exemption; Summary of Petition Received AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of petition for exemption received. SUMMARY: This notice contains a summary of a petition...
78 FR 53186 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2013-08-28
... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration [Summary Notice No. PE-2013-40] Petition for Exemption; Summary of Petition Received AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of petition for exemption received. SUMMARY: This notice contains a summary of a petition...
78 FR 21702 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-11
... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration [Summary Notice No. PE-2013-15] Petition for Exemption; Summary of Petition Received AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of petition for exemption received. SUMMARY: This notice contains a summary of a petition...
75 FR 21387 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-23
... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration [Summary Notice No. PE-2010-20] Petition for Exemption; Summary of Petition Received AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of petition for exemption received. SUMMARY: This notice contains a summary of a petition...
77 FR 29444 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-17
... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration [Summary Notice No. PE-2012-17] Petition for Exemption; Summary of Petition Received AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of petition for exemption received. SUMMARY: This notice contains a summary of a petition...
77 FR 67438 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2012-11-09
... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration [Summary Notice No. PE-2012-46] Petition for Exemption; Summary of Petition Received AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of petition for exemption received. SUMMARY: This notice contains a summary of a petition...
78 FR 68135 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2013-11-13
... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration [Summary Notice No. PE-2013-39] Petition for Exemption; Summary of Petition Received AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of petition for exemption received. SUMMARY: This notice contains a summary of a petition...
77 FR 13384 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-06
... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration [Summary Notice No. PE-2012-07] Petition for Exemption; Summary of Petition Received AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of petition for exemption received. SUMMARY: This notice contains a summary of a petition...
78 FR 13745 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2013-02-28
... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration [Summary Notice No. PE-2013-06] Petition for Exemption; Summary of Petition Received AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of petition for exemption received. SUMMARY: This notice contains a summary of a petition...
77 FR 44309 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2012-07-27
... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration [Summary Notice No. PE-2012-27] Petition for Exemption; Summary of Petition Received AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of petition for exemption received. SUMMARY: This notice contains a summary of a petition...
77 FR 29444 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-17
... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration [Summary Notice No. PE-2012-16] Petition for Exemption; Summary of Petition Received AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of petition for exemption received. SUMMARY: This notice contains a summary of a petition...
75 FR 10342 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2010-03-05
... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration [Summary Notice No. PE-2010-06] Petition for Exemption; Summary of Petition Received AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of petition for exemption received. SUMMARY: This notice contains a summary of a petition...
78 FR 67442 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2013-11-12
... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration [Summary Notice No. PE-2013-53] Petition for Exemption; Summary of Petition Received AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of petition for exemption received. SUMMARY: This notice contains a summary of a petition...
78 FR 4190 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2013-01-18
... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration [Summary Notice No. PE-2012-63] Petition for Exemption; Summary of Petition Received AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of petition for exemption received. SUMMARY: This notice contains a summary of a petition...
78 FR 21701 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-11
... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration [Summary Notice No. PE-2013-14] Petition for Exemption; Summary of Petition Received AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of petition for exemption received. SUMMARY: This notice contains a summary of a petition...
78 FR 21702 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-11
... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration [Summary Notice No. PE-2013-02] Petition for Exemption; Summary of Petition Received AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of petition for exemption received. SUMMARY: This notice contains a summary of a petition...
78 FR 46672 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2013-08-01
... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration [Summary Notice No. PE-2013-32] Petition for Exemption; Summary of Petition Received AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of petition for exemption received. SUMMARY: This notice contains a summary of a petition...
A Summary Score for the Framingham Heart Study Neuropsychological Battery
Downer, Brian; Fardo, David W.; Schmitt, Frederick A.
2015-01-01
Objective To calculate three summary scores of the Framingham Heart Study neuropsychological battery and determine which score best differentiates between subjects classified as having normal cognition, test-based impaired learning and memory, test-based multidomain impairment, and dementia. Method The final sample included 2,503 participants. Three summary scores were assessed: (a) composite score that provided equal weight to each subtest, (b) composite score that provided equal weight to each cognitive domain assessed by the neuropsychological battery, and (c) abbreviated score comprised of subtests for learning and memory. Receiver operating characteristic analysis was used to determine which summary score best differentiated between the four cognitive states. Results The summary score that provided equal weight to each subtest best differentiated between the four cognitive states. Discussion A summary score that provides equal weight to each subtest is an efficient way to utilize all of the cognitive data collected by a neuropsychological battery. PMID:25804903
A Summary Score for the Framingham Heart Study Neuropsychological Battery.
Downer, Brian; Fardo, David W; Schmitt, Frederick A
2015-10-01
To calculate three summary scores of the Framingham Heart Study neuropsychological battery and determine which score best differentiates between subjects classified as having normal cognition, test-based impaired learning and memory, test-based multidomain impairment, and dementia. The final sample included 2,503 participants. Three summary scores were assessed: (a) composite score that provided equal weight to each subtest, (b) composite score that provided equal weight to each cognitive domain assessed by the neuropsychological battery, and (c) abbreviated score comprised of subtests for learning and memory. Receiver operating characteristic analysis was used to determine which summary score best differentiated between the four cognitive states. The summary score that provided equal weight to each subtest best differentiated between the four cognitive states. A summary score that provides equal weight to each subtest is an efficient way to utilize all of the cognitive data collected by a neuropsychological battery. © The Author(s) 2015.
Microwave Power Transmission System Studies. Volume 1: Executive Summary
NASA Technical Reports Server (NTRS)
Maynard, O. E.; Brown, W. C.; Edwards, A.; Meltz, G.; Haley, J. T.; Howell, J. M.; Nathan, A.
1975-01-01
A study of microwave power generation, transmission, reception and control was conducted as a part of a program to demonstrate the feasibility of power transmission from geosynchronous orbit. A summary is presented of results concerning design approaches, estimated costs (ROM), critical technology, associated ground and orbital test programs with emphasis on dc to rf conversion, transmitting antenna, phase control, mechanical systems, flight operations, ground power receiving-rectifying antenna with systems analysis, and evaluation. Recommendations for early further in-depth studies complementing the technology program are included.
Parabolic dish test site: History and operating experience
NASA Technical Reports Server (NTRS)
Selcuk, M. K. (Compiler)
1985-01-01
The parabolic dish test site (PDTS) was established for testing point-focusing solar concentrator systems operating at temperatures approaching 1650 C. Among tests run were evaluation and performance characterization of parabolic dish concentrators, receivers, power conversion units, and solar/fossil-fuel hybrid systems. The PDTS was fully operational until its closure in June, 1984. The evolution of the test program, a chronological listing of the experiments run, and data summaries for most of the tests conducted are presented.
78 FR 39824 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2013-07-02
...] Petition for Exemption; Summary of Petition Received AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of petition for exemption received. SUMMARY: This notice contains a summary of a petition... information in the summary is intended to affect the legal status of the petition or its final disposition...
78 FR 978 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2013-01-07
...] Petition for Exemption; Summary of Petition Received AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of petition for exemption received. SUMMARY: This notice contains a summary of a petition... information in the summary is intended to affect the legal status of the petition or its final disposition...
78 FR 17746 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2013-03-22
...] Petition for Exemption; Summary of Petition Received AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of petition for exemption received. SUMMARY: This notice contains a summary of a petition... information in the summary is intended to affect the legal status of the petition or its final disposition...
40 CFR 240.211-3 - Recommended procedures: Operations.
Code of Federal Regulations, 2010 CFR
2010-07-01
... measurements and laboratory analyses required by the responsible agency. (12) Complete records of monitoring... waste received and processed, summarized on a monthly basis. (2) A summary of the laboratory analyses including at least monthly averages. (3) Number and qualifications of personnel in each job category; total...
75 FR 21389 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-23
... seeking relief from specified requirements of 14 CFR. The purpose of this notice is to improve the public... (UK), and German ProSieben scientific demonstration and filming operation for television broadcast... aerial filming and television exhibition by controlling a large passenger aircraft into a precise...
1987-01-01
Headquarters Services Directorate for Information Operations and Reports D) ,( /NT IS lientitra on nn Iber for hIs bh act& r, s (i0 ’F H 7 FOREWORD 500...This report provides information on the 500 contractors that received the largest dollar volume in Department of Defense (DOD) prime contract awards... report presents summary data on the 500 prime contractors receiving the largest dollar volume in Department of Defense (DOD) awards over $25,000 for
The Diagnostic Value of the FIB-4 Index for Staging Hepatitis B-Related Fibrosis: A Meta-Analysis
Li, Yuanyuan; Chen, Yu; Zhao, Ying
2014-01-01
Background Liver fibrosis stage is an important factor in determining prognosis and need for treatment in patients infected with hepatitis B virus (HBV). Liver biopsies are typically used to assess liver fibrosis; however, noninvasive alternatives such as the FIB-4 index have also been developed. Aims To quantify the accuracy of the FIB-4 index in the diagnosis of HBV related fibrosis and cirrhosis. Methods A meta-analysis of studies comparing the diagnostic accuracy of the FIB-4 index vs. liver biopsy in HBV-infected patients was performed using studies retrieved from the following databases: PubMed, Ovid, EMBASE, the Cochrane Library, the Chinese National Knowledge Infrastructure and the Chinese Biology Medicine disc. A hierarchical summary receiver operating curves model and bivariate model were used to produce summary receiver operating characteristic curves and pooled estimates of sensitivity and specificity. The heterogeneity was explored with meta-regression analysis. Publication bias was detected using Egger’s test and the trim and fill method. Results 12 studies (N = 1,908) and 10 studies (N = 2,105) were included in the meta-analysis for significant fibrosis and cirrhosis, respectively. For significant fibrosis, the area under the hierarchical summary receiver operating curve (AUHSROC) was 0.78 (95% CI = 0.74–0.81). The recommended cutoff value was between 1.45 and 1.62, and the AUHSROC, summary sensitivity and specificity were 0.78 (95% CI = 0.74–0.81), 0.65 (95% CI = 0.56–0.73) and 0.77 (95% CI = 0.7–0.83), respectively. For cirrhosis, the AUHSROC was 0.89 (95% CI = 0.85–0.91). The recommended cutoff value was between 2.9 and 3.6, and the AUHSROC, summary sensitivity and specificity were 0.96 (95% CI = 0.92–1.00), 0.42 (95% CI = 0.36–0.48) and 0.96 (95% CI = 0.95–0.97), respectively. No publication bias was detected. Conclusions The FIB-4 index is valuable for detecting significant fibrosis and cirrhosis in HBV-infected patients, but has suboptimal accuracy in excluding fibrosis and cirrhosis. PMID:25165830
77 FR 48202 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2012-08-13
... information you provide. Using the search function of our docket Web site, anyone can find and read the....1309(c) and (d). Description of Relief Sought: Gulfstream requests relief from certain engine installation, operational limitation and engine indication requirements which apply to the Gulfstream G280...
77 FR 31064 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-24
...] Petition for Exemption; Summary of Petition Received AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of petition for exemption received. SUMMARY: This notice contains a summary of a petition... the legal status of the petition or its final disposition. DATES: Comments on this petition must...
78 FR 53818 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2013-08-30
...] Petition for Exemption; Summary of Petition Received AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of petition for exemption received. SUMMARY: This notice contains a summary of a petition... the legal status of the petition or its final disposition. DATES: Comments on this petition must...
78 FR 24290 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-24
...] Petition for Exemption; Summary of Petition Received AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of petition for exemption received. SUMMARY: This notice contains a summary of a petition... the legal status of the petition or its final disposition. DATES: Comments on this petition must...
78 FR 17746 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2013-03-22
...] Petition for Exemption; Summary of Petition Received AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of petition for exemption received. SUMMARY: This notice contains a summary of a petition... the legal status of the petition or its final disposition. DATES: Comments on this petition must...
77 FR 36333 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2012-06-18
...] Petition for Exemption; Summary of Petition Received AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of petition for exemption received. SUMMARY: This notice contains a summary of a petition... the legal status of the petition or its final disposition. DATES: Comments on this petition must...
75 FR 20881 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-21
...] Petition for Exemption; Summary of Petition Received AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of petition for exemption received. SUMMARY: This notice contains a summary of a petition... the legal status of the petition or its final disposition. DATES: Comments on this petition must...
77 FR 58210 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2012-09-19
...] Petition for Exemption; Summary of Petition Received AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of petition for exemption received. SUMMARY: This notice contains a summary of a petition... the legal status of the petition or its final disposition. DATES: Comments on this petition must...
78 FR 35353 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2013-06-12
...] Petition for Exemption; Summary of Petition Received AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of petition for exemption received. SUMMARY: This notice contains a summary of a petition... the legal status of the petition or its final disposition. DATES: Comments on this petition must...
75 FR 60859 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2010-10-01
...] Petition for Exemption; Summary of Petition Received AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of petition for exemption received. SUMMARY: This notice contains a summary of a petition... the legal status of the petition or its final disposition. DATES: Comments on this petition must...
77 FR 35103 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2012-06-12
...] Petition for Exemption; Summary of Petition Received AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of petition for exemption received. SUMMARY: This notice contains a summary of a petition... the legal status of the petition or its final disposition. DATES: Comments on this petition must...
78 FR 56768 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-13
...] Petition for Exemption; Summary of Petition Received AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of petition for exemption received. SUMMARY: This notice contains a summary of a petition... the legal status of the petition or its final disposition. DATES: Comments on this petition must...
75 FR 26839 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2010-05-12
...] Petition for Exemption; Summary of Petition Received AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of petition for exemption received. SUMMARY: This notice contains a summary of a petition... the legal status of the petition or its final disposition. DATES: Comments on this petition must...
78 FR 66098 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2013-11-04
...] Petition for Exemption; Summary of Petition Received AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of petition for exemption received. SUMMARY: This notice contains a summary of a petition... the legal status of the petition or its final disposition. DATES: Comments on this petition must...
76 FR 9852 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2011-02-22
...] Petition for Exemption; Summary of Petition Received AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of petition for exemption received. SUMMARY: This notice contains a summary of a petition... the legal status of the petition or its final disposition. DATES: Comments on this petition must...
78 FR 978 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2013-01-07
...] Petition for Exemption; Summary of Petition Received AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of petition for exemption received. SUMMARY: This notice contains a summary of a petition... the legal status of the petition or its final disposition. DATES: Comments on this petition must...
76 FR 2746 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2011-01-14
...] Petition for Exemption; Summary of Petition Received AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of petition for exemption received. SUMMARY: This notice contains a summary of a petition... the legal status of the petition or its final disposition. DATES: Comments on this petition must...
78 FR 34139 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2013-06-06
...] Petition for Exemption; Summary of Petition Received AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of petition for exemption received. SUMMARY: This notice contains a summary of a petition... the legal status of the petition or its final disposition. DATES: Comments on this petition must...
76 FR 51119 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-17
...] Petition for Exemption; Summary of Petition Received AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of petition for exemption received. SUMMARY: This notice contains a summary of a petition... the legal status of the petition or its final disposition. DATES: Comments on this petition must...
78 FR 39825 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2013-07-02
...] Petition for Exemption; Summary of Petition Received AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of petition for exemption received. SUMMARY: This notice contains a summary of a petition... the legal status of the petition or its final disposition. DATES: Comments on this petition must...
78 FR 979 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2013-01-07
...] Petition for Exemption; Summary of Petition Received AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of petition for exemption received. SUMMARY: This notice contains a summary of a petition... the legal status of the petition or its final disposition. DATES: Comments on this petition must...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-08-15
... Marine Mammals Incidental to Specified Activities; U.S. Air Force Launches, Aircraft and Helicopter Operations, and Harbor Activities Related to Launch Vehicles From Vandenberg Air Force Base (VAFB... comments and information. SUMMARY: NMFS has received a request from the U.S. Air Force (USAF) for...
75 FR 32117 - Proposed Amendment of Colored Federal Airway B-38; Alaska
Federal Register 2010, 2011, 2012, 2013, 2014
2010-06-07
...). SUMMARY: This action proposes to amend Colored Federal Airway Blue 38 (B-38), in Alaska. Specifically this... the proposed rule. The proposal contained in this action may be changed in light of comments received... operational. NAV CANADA determined it is no longer feasible and will be decommissioning the XY NDB. Blue...
77 FR 9696 - Notice of Proposed Reinstatement of Terminated Oil and Gas Lease COC68134
Federal Register 2010, 2011, 2012, 2013, 2014
2012-02-17
...] Notice of Proposed Reinstatement of Terminated Oil and Gas Lease COC68134 AGENCY: Bureau of Land Management, Interior. ACTION: Notice of Proposed Reinstatement of Terminated Oil and Gas Lease. SUMMARY... Management (BLM) received a petition for reinstatement of oil and gas lease COC68134 from Western Operation...
76 FR 410 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2011-01-04
...: Fax comments to the Docket Management Facility at 202-493-2251. Hand Delivery: Bring comments to the... Federal holidays. FOR FURTHER INFORMATION CONTACT: Frances Shaver, ARM-207, (202) 267- 4059, FAA, Office... operational TCAS software and therefore has no impact on the safety performance of the system. [FR Doc. 2010...
77 FR 47912 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2012-08-10
..., Office of Rulemaking. Petition for Exemption Docket No.: FAA-2012-0615. Petitioner: Arctic Air Alaska...: Arctic Air Alaska, Inc. requests relief from Sec. 135.203(a)(1) so they may operate flights for the... any obstacle. This would allow Arctic Air Alaska, Inc. to comply with Sec. 91.119, Minimum Safe...
Geochemistry of coalbed gas - a review
Clayton, J.L.
1998-01-01
Coals are both sources and reservoirs of large amounts of gas that has received increasing attention in recent years as a largely untapped potential energy resource. Coal mining operations, such as ventilation of coalbed gas from underground mines, release coalbed CH4 into the atmosphere, an important greehouse gas whose concentration in the atmosphere is increasing. Because of these energy and environmental issues, increased research attention has been focused on the geochemistry of coalbed gas in recent years. This paper presents a summary review of the main aspects of coalbed gas geochemistry and current research advances.Coals are both sources and reservoirs of large amounts of gas that has received increasing attention in recent years as a largely untapped potential energy resource. Coal mining operations, such as ventilation of coalbed gas from underground mines, release coalbed CH4 into the atmosphere, an important greenhouse gas whose concentration in the atmosphere is increasing. Because of these energy and environmental issues, increased research attention has been focused on the geochemistry of coalbed gas in recent years. This paper presents a summary review of the main aspects of coalbed gas geochemistry and current research advances.
Uzzan, Bernard; Cohen, Régis; Nicolas, Patrick; Cucherat, Michel; Perret, Gérard-Yves
2006-07-01
To quantify the accuracy of serum procalcitonin as a diagnostic test for sepsis, severe sepsis, or septic shock in adults in intensive care units or after surgery or trauma, alone and compared with C-reactive protein. To draw and compare the summary receiver operating characteristics curves for procalcitonin and C-reactive protein from the literature. MEDLINE (keywords: procalcitonin, intensive care, sepsis, postoperative sepsis, trauma); screening of the literature. Meta-analysis of all 49 published studies in medical, surgical, or polyvalent intensive care units or postoperative wards. Children, medical patients, and immunocompromised patients were excluded. Thirty-three studies fulfilled inclusion criteria (3,943 patients, 1,828 males, 922 females; mean age: 56.1 yrs; 1,825 patients with sepsis, severe sepsis, or septic shock; 1,545 with only systemic inflammatory response syndrome); eight studies could not be analyzed statistically. Global mortality rate was 29.3%. Global odds ratios for diagnosis of infection complicated by systemic inflammation were 15.7 for the 25 studies (2,966 patients) using procalcitonin (95% confidence interval, 9.1-27.1) and 5.4 for the 15 studies (1,322 patients) using C-reactive protein (95% confidence interval, 3.2-9.2). The summary receiver operating characteristics curve for procalcitonin was better than for C-reactive protein. In the 15 studies using both markers, the Q* value (intersection of summary receiver operating characteristics curve with the diagonal line where sensitivity equals specificity) was significantly higher for procalcitonin than for C-reactive protein (0.78 vs. 0.71, p = .02), the former test showing better accuracy. Procalcitonin represents a good biological diagnostic marker for sepsis, severe sepsis, or septic shock, difficult diagnoses in critically ill patients. Procalcitonin is superior to C-reactive protein. Procalcitonin should be included in diagnostic guidelines for sepsis and in clinical practice in intensive care units.
NASA Technical Reports Server (NTRS)
1978-01-01
The mission of the microwave atmospheric sounding radiometer (MASR) is to collect data to aid in the observation and prediction of severe storms. The geosynchronous orbit allows the continuous atmospheric measurement needed to resolve mesoscale dynamics. The instrument may operate in conjunction with this document, Volume 1 - Management, which summarizes the highlights of final reports on both the radiometer instrument and antenna studies. The radiometer instrument summary includes a synopsis of Volume 2 - Radiometer Receiver Feasibility, including design, recommended configuration, performance estimates, and weight and power estimates. The summary of the antenna study includes a synopsis of Volume 3 - Antenna Feasibility, including preliminary design tradeoffs, performance of selected design, and details of the mechanical/thermal design.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-06-18
... Protection Agency (EPA). ACTION: Extension of public comment period. SUMMARY: On March 26, 2012, the EPA... extending the deadline for written comments on the proposed amendments by 90 days to September 24, 2012. The... affected by this action. DATES: Comments must be received on or before September 24, 2012. ADDRESSES...
Attention that Indicators Receive in the Press
ERIC Educational Resources Information Center
Hendriks, Maria; Barzano, Giovanna; Brumana, Emanuela; Cremonesi, Claudia
2004-01-01
With the release of each edition of Education at a Glance, the Office for Economic Co-operation and Development (OECD) prepares a press briefing to be used for the international press release and which individual countries in preparing their national press releases can also use. Similarly, the European Union prepares a summary, not for use at the…
Federal Register 2010, 2011, 2012, 2013, 2014
2012-12-19
... DEPARTMENT OF STATE [Public Notice: 8128] Notice of Receipt of Kinder Morgan Cochin, LLC... States and Canada AGENCY: Department of State. ACTION: Notice of Receipt of Kinder Morgan Cochin, LLC... States and Canada. SUMMARY: Notice is hereby given that the Department of State (DOS) has received from...
Bernabeu-Mora, Roberto; Medina-Mirapeix, Françesc; Llamazares-Herrán, Eduardo; García-Guillamón, Gloria; Giménez-Giménez, Luz María; Sánchez-Nieto, Juan Miguel
2015-01-01
Limited mobility is a risk factor for developing chronic obstructive pulmonary disease (COPD)-related disabilities. Little is known about the validity of the Short Physical Performance Battery (SPPB) for identifying mobility limitations in patients with COPD. To determine the clinical validity of the SPPB summary score and its three components (standing balance, 4-meter gait speed, and five-repetition sit-to-stand) for identifying mobility limitations in patients with COPD. This cross-sectional study included 137 patients with COPD, recruited from a hospital in Spain. Muscle strength tests and SPPB were measured; then, patients were surveyed for self-reported mobility limitations. The validity of SPPB scores was analyzed by developing receiver operating characteristic curves to analyze the sensitivity and specificity for identifying patients with mobility limitations; by examining group differences in SPPB scores across categories of mobility activities; and by correlating SPPB scores to strength tests. Only the SPPB summary score and the five-repetition sit-to-stand components showed good discriminative capabilities; both showed areas under the receiver operating characteristic curves greater than 0.7. Patients with limitations had significantly lower SPPB scores than patients without limitations in nine different mobility activities. SPPB scores were moderately correlated with the quadriceps test (r>0.40), and less correlated with the handgrip test (r<0.30), which reinforced convergent and divergent validities. A SPPB summary score cutoff of 10 provided the best accuracy for identifying mobility limitations. This study provided evidence for the validity of the SPPB summary score and the five-repetition sit-to-stand test for assessing mobility in patients with COPD. These tests also showed potential as a screening test for identifying patients with COPD that have mobility limitations.
Bernabeu-Mora, Roberto; Medina-Mirapeix, Françesc; Llamazares-Herrán, Eduardo; García-Guillamón, Gloria; Giménez-Giménez, Luz María; Sánchez-Nieto, Juan Miguel
2015-01-01
Background Limited mobility is a risk factor for developing chronic obstructive pulmonary disease (COPD)-related disabilities. Little is known about the validity of the Short Physical Performance Battery (SPPB) for identifying mobility limitations in patients with COPD. Objective To determine the clinical validity of the SPPB summary score and its three components (standing balance, 4-meter gait speed, and five-repetition sit-to-stand) for identifying mobility limitations in patients with COPD. Methods This cross-sectional study included 137 patients with COPD, recruited from a hospital in Spain. Muscle strength tests and SPPB were measured; then, patients were surveyed for self-reported mobility limitations. The validity of SPPB scores was analyzed by developing receiver operating characteristic curves to analyze the sensitivity and specificity for identifying patients with mobility limitations; by examining group differences in SPPB scores across categories of mobility activities; and by correlating SPPB scores to strength tests. Results Only the SPPB summary score and the five-repetition sit-to-stand components showed good discriminative capabilities; both showed areas under the receiver operating characteristic curves greater than 0.7. Patients with limitations had significantly lower SPPB scores than patients without limitations in nine different mobility activities. SPPB scores were moderately correlated with the quadriceps test (r>0.40), and less correlated with the handgrip test (r<0.30), which reinforced convergent and divergent validities. A SPPB summary score cutoff of 10 provided the best accuracy for identifying mobility limitations. Conclusion This study provided evidence for the validity of the SPPB summary score and the five-repetition sit-to-stand test for assessing mobility in patients with COPD. These tests also showed potential as a screening test for identifying patients with COPD that have mobility limitations. PMID:26664110
75 FR 21387 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-23
... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration [Summary Notice No. PE-2010-19] Petition for Exemption; Summary of Petition Received AGENCY: Federal Aviation Administration (FAA), DOT. [[Page 21388
78 FR 69929 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2013-11-21
... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration [Summary Notice No. PE-2013-54] Petition for Exemption; Summary of Petition Received AGENCY: Federal Aviation Administration (FAA), DOT. [[Page 69930
McGrath, Trevor A; McInnes, Matthew D F; Korevaar, Daniël A; Bossuyt, Patrick M M
2016-10-01
Purpose To determine whether authors of systematic reviews of diagnostic accuracy studies published in imaging journals used recommended methods for meta-analysis, and to evaluate the effect of traditional methods on summary estimates of sensitivity and specificity. Materials and Methods Medline was searched for published systematic reviews that included meta-analysis of test accuracy data limited to imaging journals published from January 2005 to May 2015. Two reviewers independently extracted study data and classified methods for meta-analysis as traditional (univariate fixed- or random-effects pooling or summary receiver operating characteristic curve) or recommended (bivariate model or hierarchic summary receiver operating characteristic curve). Use of methods was analyzed for variation with time, geographical location, subspecialty, and journal. Results from reviews in which study authors used traditional univariate pooling methods were recalculated with a bivariate model. Results Three hundred reviews met the inclusion criteria, and in 118 (39%) of those, authors used recommended meta-analysis methods. No change in the method used was observed with time (r = 0.54, P = .09); however, there was geographic (χ(2) = 15.7, P = .001), subspecialty (χ(2) = 46.7, P < .001), and journal (χ(2) = 27.6, P < .001) heterogeneity. Fifty-one univariate random-effects meta-analyses were reanalyzed with the bivariate model; the average change in the summary estimate was -1.4% (P < .001) for sensitivity and -2.5% (P < .001) for specificity. The average change in width of the confidence interval was 7.7% (P < .001) for sensitivity and 9.9% (P ≤ .001) for specificity. Conclusion Recommended methods for meta-analysis of diagnostic accuracy in imaging journals are used in a minority of reviews; this has not changed significantly with time. Traditional (univariate) methods allow overestimation of diagnostic accuracy and provide narrower confidence intervals than do recommended (bivariate) methods. (©) RSNA, 2016 Online supplemental material is available for this article.
ERIC Educational Resources Information Center
Denton, J. J.; Denton, M. H.; Kavanagh, A. J.; Harron, H.; Ulich, T.; Denton, J. S.
2012-01-01
We report on a school-university collaboration to involve students in the deployment, testing, and operation of a very low frequency (VLF) radio receiver as part of an international network of such experiments. A background to the collaboration is presented, along with a summary of planning and development, and the ultimate deployment of the…
Time-dependent summary receiver operating characteristics for meta-analysis of prognostic studies.
Hattori, Satoshi; Zhou, Xiao-Hua
2016-11-20
Prognostic studies are widely conducted to examine whether biomarkers are associated with patient's prognoses and play important roles in medical decisions. Because findings from one prognostic study may be very limited, meta-analyses may be useful to obtain sound evidence. However, prognostic studies are often analyzed by relying on a study-specific cut-off value, which can lead to difficulty in applying the standard meta-analysis techniques. In this paper, we propose two methods to estimate a time-dependent version of the summary receiver operating characteristics curve for meta-analyses of prognostic studies with a right-censored time-to-event outcome. We introduce a bivariate normal model for the pair of time-dependent sensitivity and specificity and propose a method to form inferences based on summary statistics reported in published papers. This method provides a valid inference asymptotically. In addition, we consider a bivariate binomial model. To draw inferences from this bivariate binomial model, we introduce a multiple imputation method. The multiple imputation is found to be approximately proper multiple imputation, and thus the standard Rubin's variance formula is justified from a Bayesian view point. Our simulation study and application to a real dataset revealed that both methods work well with a moderate or large number of studies and the bivariate binomial model coupled with the multiple imputation outperforms the bivariate normal model with a small number of studies. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Correction to "Summary Report of Journal Operations, 2014".
2017-01-01
Reports an error in "Summary report of journal operations, 2014" by ( American Psychologist , 2015[Jul-Aug], Vol 70[5], 455-456). In the report on p. 455 the columns displaying average publication lag time for online first and print articles were reversed. In addition, the reported number of accepted manuscripts for the Journal of Personality and Social Psychology should be 118, not 65, and the rejection rate should be 86% rather than 91%. (The following abstract of the original article appeared in record 2015-33530-012.) [Correction Notice: An Erratum for this article was reported in Vol 71(9) of American Psychologist (see record 2016-61507-015). In the report, the reported number of manuscripts received, accepted, and pending along with their accompanying rejection rates had errors in the following journals: Journal of Abnormal Psychology; Journal of Applied Psychology; Journal of Consulting and Clinical Psychology; Journal of Counseling Psychology; Journal of Experimental Psychology: General; Journal of Family Psychology; Journal of Personality and Social Psychology; Psychological Assessment; Psychological Methods; Psychological Review; Psychology and Aging; Psychology of Addictive Behaviors; Psychology, Public Policy, and Law; and Analyses of Social Issues and Public Policy. The online version of this report has been corrected.] Presents the American Psychological Association's summary report of its journal operations and division journal operations for 2014. (PsycINFO Database Record (c) 2017 APA, all rights reserved).
Spread Spectrum Receiver Electromagnetic Interference (EMI) Test Guide
NASA Technical Reports Server (NTRS)
Wheeler, M. L.
1998-01-01
The objective of this test guide is to document appropriate unit level test methods and techniques for the performance of EMI testing of Direct Sequence (DS) spread spectrum receivers. Consideration of EMI test methods tailored for spread spectrum receivers utilizing frequency spreading, techniques other than direct sequence (such as frequency hopping, frequency chirping, and various hybrid methods) is beyond the scope of this test guide development program and is not addressed as part of this document EMI test requirements for NASA programs are primarily developed based on the requirements contained in MIL-STD-46 1 D (or earlier revisions of MIL-STD-46 1). The corresponding test method guidelines for the MIL-STD-461 D tests are provided in MIL-STD-462D. These test methods are well documented with the exception of the receiver antenna port susceptibility tests (intermodulation, cross modulation, and rejection of undesired signals) which must be tailored to the specific type of receiver that is being tested. Thus, test methods addressed in this guide consist only of antenna port tests designed to evaluate receiver susceptibility characteristics. MIL-STD-462D should be referred for guidance pertaining to test methods for EMI tests other than the antenna port tests. The scope of this test guide includes: (1) a discussion of generic DS receiver performance characteristics; (2) a summary of S-band TDRSS receiver operation; (3) a discussion of DS receiver EMI susceptibility mechanisms and characteristics; (4) a summary of military standard test guidelines; (5) recommended test approach and methods; and (6) general conclusions and recommendations for future studies in the area of spread spectrum receiver testing.
Effect of preoperative suggestion on postoperative gastrointestinal motility.
Disbrow, E A; Bennett, H L; Owings, J T
1993-01-01
Autonomic behavior is subject to direct suggestion. We found that patients undergoing major operations benefit more from instruction than from information and reassurance. We compared the return of intestinal function after intra-abdominal operations in 2 groups of patients: the suggestion group received specific instructions for the early return of gastrointestinal motility, and the control group received an equal-length interview offering reassurance and nonspecific instructions. The suggestion group had a significantly shorter average time to the return of intestinal motility, 2.6 versus 4.1 days. Time to discharge was 6.5 versus 8.1 days. Covariates including duration of operation, amount of intraoperative bowel manipulation, and amount of postoperative narcotics were also examined using the statistical model analysis of covariance. An average savings of $1,200 per patient resulted from this simple 5-minute intervention. In summary, the use of specific physiologically active suggestions given preoperatively in a beleivable manner can reduce the morbidity associated with an intra-abdominal operation by reducing the duration of ileus. PMID:8342264
75 FR 68666 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2010-11-08
... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration [Summary Notice No. PE-2010-48] Petition for Exemption; Summary of Petition Received AGENCY: Federal Aviation Administration (FAA), DOT..., Federal Aviation Administration, 1601 Lind Avenue, SW., Renton, WA 98057-3356, or Katherine Haley, (202...
75 FR 4904 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2010-01-29
... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration [Summary Notice No. PE-2009-61] Petition for Exemption; Summary of Petition Received Correction In notice document 2010-808 beginning on page 2925 in the issue of Tuesday, January 19, 2010, make the following correction: On page 2925, in...
JPRS Report. Soviet Union: World Economy & International Relations
1987-11-19
period of time the strategy and tactics of PRM: relations between the PRM and the Palestine Liberation Organization (PLO), the prospects of the...lowing the flood season period the Red Army would right away switch to active operations to liberate the occupied oblasts. Its intentions in summary...received positively by the leadership of many influential organizations which are a part of the PLO—the Demo- cratic Front for the Liberation of
Calendar Year 2002 Pollution Prevention Annual Data Summary (P2ADS)
2003-07-01
trfkb.navy.mil NAVAL WEAPONS STATION EARLE COLTS NECK, NJ 11. Success Description: NWS Earle receives most of its hazardous waste from home ported...offload operations must be done within very A-5 Appendix A COMMANDER U.S. ATLANTIC FLEET (LANTFLT) NAVAL WEAPONS STATION EARLE COLTS NECK, NJ...2339 Code: N8E Fax: (732) 866-1290 Email: dswalwel@earle.navy.mil NAVAL WEAPONS STATION YORKTOWN, VA 12. Success Description: Aqueous weapons
Liu, Bo-Ji; Li, Dan-Dan; Xu, Hui-Xiong; Guo, Le-Hang; Zhang, Yi-Feng; Xu, Jun-Mei; Liu, Chang; Liu, Lin-Na; Li, Xiao-Long; Xu, Xiao-Hong; Qu, Shen; Xing, Mingzhao
2015-12-01
The aim of this study was to evaluate the diagnostic performance of quantitative shear wave velocity (SWV) measurement on acoustic radiation force impulse (ARFI) elastography for differentiation between benign and malignant thyroid nodules using meta-analysis. The databases of PubMed and the Web of Science were searched. Studies published in English on assessment of the sensitivity and specificity of ARFI elastography for the differentiation of thyroid nodules were collected. The quantitative measurement of ARFI elastography was evaluated by SWV (m/s). Meta-Disc Version 1.4 software was used to describe and calculate the sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, diagnostic odds ratio and summary receiver operating characteristic curves. We analyzed a total of 13 studies, which included 1,854 thyroid nodules (including 1,339 benign nodules and 515 malignant nodules) from 1,641 patients. The summary sensitivity and specificity for differential diagnosis between benign and malignant thyroid nodules by SWV were 0.81 (95% confidence interval [CI]: 0.77-0.84) and 0.84 (95% CI: 0.81-0.86), respectively. The pooled positive and negative likelihood ratios were 5.21 (95% CI: 3.56-7.62) and 0.23 (95% CI: 0.17-0.32), respectively. The pooled diagnostic odds ratio was 27.53 (95% CI: 14.58-52.01), and the area under the summary receiver operating characteristic curve was 0.91 (Q* = 0.84). In conclusion, SWV measurement on ARFI elastography has high sensitivity and specificity for differential diagnosis between benign and malignant thyroid nodules and can be used in combination with conventional ultrasound. Copyright © 2015 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
1991-02-01
FY 1990 ACCOMPLISHMENTS: a. (U) Completed physical functional and operational audit of system, subcomponents and interfaces related to digital...receiver hardware. b. (U) Developed system specification reflecting audit results. c. (U) Established reliability assessment and recommended changes and/or...interoperability testing and demonstrations. d. (U) Updated joint terminal specifications and standards. e. (U) Audited Army/Navy/Air Force terminal designs. f. (U
The Exon-Florio National Security Test for Foreign Investment
2006-03-15
Congressional Research Service ˜ The Library of Congress CRS Report for Congress Received through the CRS Web Order Code RL33312 The Exon- Florio ...number. 1. REPORT DATE 15 MAR 2006 2. REPORT TYPE N/A 3. DATES COVERED - 4. TITLE AND SUBTITLE The Exon- Florio National Security Test for...Z39-18 The Exon- Florio National Security Test for Foreign Investment Summary The proposed acquisitions of major operations in six major U.S. ports by
Man, Wanrong; Hu, Jianqiang; Zhao, Zhijing; Zhang, Mingming; Wang, Tingting; Lin, Jie; Duan, Yu; Wang, Ling; Wang, Haichang; Sun, Dongdong; Li, Yan
2016-09-01
The instantaneous wave-free ratio (iFR) is a new vasodilator-free index of coronary stenosis severity. The aim of this meta-analysis is to assess the diagnostic performance of iFR for the evaluation of coronary stenosis severity with fractional flow reserve as standard reference. We searched PubMed, EMBASE, CENTRAL, ProQuest, Web of Science, and International Clinical Trials Registry Platform (ICTRP) for publications concerning the diagnostic value of iFR. We used a random-effects covariate to synthesize the available data of sensitivity, specificity, positive likelihood ratio (LR+), negative likelihood ratio (LR-), and diagnostic odds ratio (DOR). Overall test performance was summarized by the summary receiver operating characteristic curve (sROC) and the area under the curve (AUC). Eight studies with 1611 subjects were included in the meta-analysis. The pooled sensitivity, specificity, LR+, LR-, and DOR for iFR were respectively 73.3% (70.1-76.2%), 86.4% (84.3-88.3%), 5.71 (4.43-7.37), 0.29 (0.22-0.38), and 20.54 (16.11-26.20). The area under the summary receiver operating characteristic curves for iFR was 0.8786. No publication bias was identified. The available evidence suggests that iFR may be a new, simple, and promising technology for coronary stenosis physiological assessment.
Evaluation of predictive capacities of biomarkers based on research synthesis.
Hattori, Satoshi; Zhou, Xiao-Hua
2016-11-10
The objective of diagnostic studies or prognostic studies is to evaluate and compare predictive capacities of biomarkers. Suppose we are interested in evaluation and comparison of predictive capacities of continuous biomarkers for a binary outcome based on research synthesis. In analysis of each study, subjects are often classified into two groups of the high-expression and low-expression groups according to a cut-off value, and statistical analysis is based on a 2 × 2 table defined by the response and the high expression or low expression of the biomarker. Because the cut-off is study specific, it is difficult to interpret a combined summary measure such as an odds ratio based on the standard meta-analysis techniques. The summary receiver operating characteristic curve is a useful method for meta-analysis of diagnostic studies in the presence of heterogeneity of cut-off values to examine discriminative capacities of biomarkers. We develop a method to estimate positive or negative predictive curves, which are alternative to the receiver operating characteristic curve based on information reported in published papers of each study. These predictive curves provide a useful graphical presentation of pairs of positive and negative predictive values and allow us to compare predictive capacities of biomarkers of different scales in the presence of heterogeneity in cut-off values among studies. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
NASA Technical Reports Server (NTRS)
Gorman, D.; Grant, C.; Kyrias, G.; Lord, C.; Rombach, J. P.; Salis, M.; Skidmore, R.; Thomas, R.
1975-01-01
A sound, practical approach for the assembly and maintenance of very large structures in space is presented. The methods and approaches for assembling two large structures are examined. The maintenance objectives include the investigation of methods to maintain five geosynchronous satellites. The two assembly examples are a 200-meter-diameter radio astronomy telescope and a 1,000-meter-diameter microwave power transmission system. The radio astronomy telescope operates at an 8,000-mile altitude and receives RF signals from space. The microwave power transmission system is part of a solar power satellite that will be used to transmit converted solar energy to microwave ground receivers. Illustrations are included.
NASA Technical Reports Server (NTRS)
1974-01-01
An experiment was conducted to measure and map the man-made radio frequency emanations which exist at earth orbital altitudes. The major objectives of the program are to develop a complete conceptual experiment and developmental hardware for the collection and processing of data required to produce meaningful statistics on man-made noise level variations as functions of time, frequency, and geographic location. A wide dispersion measurement receiver mounted in a spacecraft operating in a specialized orbit is used to obtain the data. A summary of the experiment designs goals and constraints is provided. The recommended orbit for the spacecraft is defined. The characteristics of the receiver and the antennas are analyzed.
You, Myung-Won; Kim, Kyung Won; Pyo, Junhee; Huh, Jimi; Kim, Hyoung Jung; Lee, So Jung; Park, Seong Ho
2017-01-01
We aimed to evaluate the correlation between liver stiffness measurement using transient elastography (TE-LSM) and hepatic venous pressure gradient and the diagnostic performance of TE-LSM in assessing clinically significant portal hypertension through meta-analysis. Eleven studies were included from thorough literature research and selection processes. The summary correlation coefficient was 0.783 (95% confidence interval [CI], 0.737-0.823). Summary sensitivity, specificity and area under the hierarchical summary receiver operating characteristic curve (AUC) were 87.5% (95% CI, 75.8-93.9%), 85.3 % (95% CI, 76.9-90.9%) and 0.9, respectively. The subgroup with low cut-off values of 13.6-18 kPa had better summary estimates (sensitivity 91.2%, specificity 81.3% and partial AUC 0.921) than the subgroup with high cut-off values of 21-25 kPa (sensitivity 71.2%, specificity 90.9% and partial AUC 0.769). In summary, TE-LSM correlated well with hepatic venous pressure gradient and represented good diagnostic performance in diagnosing clinically significant portal hypertension. For use as a sensitive screening tool, we propose using low cut-off values of 13.6-18 kPa in TE-LSM. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
Ma, Chunming; Liu, Yue; Lu, Qiang; Lu, Na; Liu, Xiaoli; Tian, Yiming; Wang, Rui; Yin, Fuzai
2016-02-01
The blood pressure-to-height ratio (BPHR) has been shown to be an accurate index for screening hypertension in children and adolescents. The aim of the present study was to perform a meta-analysis to assess the performance of BPHR for the assessment of hypertension. Electronic and manual searches were performed to identify studies of the BPHR. After methodological quality assessment and data extraction, pooled estimates of the sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, diagnostic odds ratio, area under the receiver operating characteristic curve and summary receiver operating characteristics were assessed systematically. The extent of heterogeneity for it was assessed. Six studies were identified for analysis. The pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio and diagnostic odds ratio values of BPHR, for assessment of hypertension, were 96% [95% confidence interval (CI)=0.95-0.97], 90% (95% CI=0.90-0.91), 10.68 (95% CI=8.03-14.21), 0.04 (95% CI=0.03-0.07) and 247.82 (95% CI=114.50-536.34), respectively. The area under the receiver operating characteristic curve was 0.9472. The BPHR had higher diagnostic accuracies for identifying hypertension in children and adolescents.
1982-02-01
control unit will detect and classify submerged submarins transiting within PJ The EnCAPsulated pedo augments air, surface and submarine anti...vidicon (date link video enhancement). Conduct Operational Test and Evaluation. Complete Large Scale Integration Receiver-Decoder improvement. Continue...analysis, and data link video enhancement focusing on application of a new silicon vidicon was continued; data link improvements such as adaptive null
University Research Consortium annual review meeting program
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1996-07-01
This brochure presents the program for the first annual review meeting of the University Research Consortium (URC) of the Idaho National Engineering Laboratory (INEL). INEL is a multiprogram laboratory with a distinctive role in applied engineering. It also conducts basic science research and development, and complex facility operations. The URC program consists of a portfolio of research projects funded by INEL and conducted at universities in the United States. In this program, summaries and participant lists for each project are presented as received from the principal investigators.
1987-03-01
received greater attention (Kalff and Knoechel 1978). As implied in the study of Nicholls, Kennedy, and Hammett (1980), and perhaps applicable 35 . I...from associated increases in DIN availability (Nicholls, Kennedy, and Hammett 1980). Since Cyanophytes among other algae are effective at luxuriously...phytoplankton % in Lake Erken. Symb. Bot. Ups. 17:163. (In German.) Nicholls, K. H., W. Kennedy, and C. Hammett . 1980. A fish-kill in Heart Lake
1989 Environmental monitoring report, Sandia National Laboratories, Albuquerque, New Mexico
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hwang, S.; Chavez, G.; Phelan, J.
1990-05-01
This 1989 report contains monitoring data from routine radiological and nonradiological environmental surveillance activities. Summaries of significant environmental compliance programs in progress such as National Environmental Policy Act documentation, environmental permits, environmental restoration, and various waste management programs for Sandia National Laboratories in Albuquerque (SNL, Albuquerque) are included. The maximum offsite dose impact was calculated to be 8.8 {times} 10{sup {minus}4} mrem. The total Albuquerque population received a collective dose of 0.097 person-rem during 1989 from SNL, Albuquerque, operations. As in the previous year, SNL, Albuquerque, operations in 1989 had no adverse impact on the general public or on themore » environment. 46 refs., 20 figs., 31 tabs.« less
Lessons Learned During Implementation and Early Operations of the DS1 Beacon Monitor Experiment
NASA Technical Reports Server (NTRS)
Sherwood, Rob; Wyatt, Jay; Hotz, Henry; Schlutsmeyer, Alan; Sue, Miles
1998-01-01
A new approach to mission operations will be flight validated on NASA's New Millennium Program Deep Space One (DS1) mission which launched in October 1998. The Beacon Monitor Operations Technology is aimed at decreasing the total volume of downlinked engineering telemetry by reducing the frequency of downlink and the volume of data received per pass. Cost savings are achieved by reducing the amount of routine telemetry processing and analysis performed by ground staff. The technology is required for upcoming NASA missions to Pluto, Europa, and possibly some other missions. With beacon monitoring, the spacecraft will assess its own health and will transmit one of four beacon messages each representing a unique frequency tone to inform the ground how urgent it is to track the spacecraft for telemetry. If all conditions are nominal, the tone provides periodic assurance to ground personnel that the mission is proceeding as planned without having to receive and analyze downlinked telemetry. If there is a problem, the tone will indicate that tracking is required and the resulting telemetry will contain a concise summary of what has occurred since the last telemetry pass. The primary components of the technology are a tone monitoring technology, AI-based software for onboard engineering data summarization, and a ground response system. In addition, there is a ground visualization system for telemetry summaries. This paper includes a description of the Beacon monitor concept, the trade-offs with adapting that concept as a technology experiment, the current state of the resulting implementation on DS1, and our lessons learned during the initial checkout phase of the mission. Applicability to future missions is also included.
Summary Report of Journal Operations, 2016.
2017-01-01
Presents a summary report of journal operations compiled from the 2016 annual reports of the Council of Editors and from Central Office records. Also includes a summary report of division journal operations compiled from the 2016 annual reports of the division journal editors. (PsycINFO Database Record (c) 2017 APA, all rights reserved).
Schlattmann, Peter; Verba, Maryna; Dewey, Marc; Walther, Mario
2015-01-01
Bivariate linear and generalized linear random effects are frequently used to perform a diagnostic meta-analysis. The objective of this article was to apply a finite mixture model of bivariate normal distributions that can be used for the construction of componentwise summary receiver operating characteristic (sROC) curves. Bivariate linear random effects and a bivariate finite mixture model are used. The latter model is developed as an extension of a univariate finite mixture model. Two examples, computed tomography (CT) angiography for ruling out coronary artery disease and procalcitonin as a diagnostic marker for sepsis, are used to estimate mean sensitivity and mean specificity and to construct sROC curves. The suggested approach of a bivariate finite mixture model identifies two latent classes of diagnostic accuracy for the CT angiography example. Both classes show high sensitivity but mainly two different levels of specificity. For the procalcitonin example, this approach identifies three latent classes of diagnostic accuracy. Here, sensitivities and specificities are quite different as such that sensitivity increases with decreasing specificity. Additionally, the model is used to construct componentwise sROC curves and to classify individual studies. The proposed method offers an alternative approach to model between-study heterogeneity in a diagnostic meta-analysis. Furthermore, it is possible to construct sROC curves even if a positive correlation between sensitivity and specificity is present. Copyright © 2015 Elsevier Inc. All rights reserved.
Goto, Eita
2011-01-01
Low birthweight should be identified early, even in developing countries where birthweight cannot be easily measured due to the absence of scales and trained staff. This meta-analysis evaluated and compared the use of other anthropometric measurements at birth to predict low birthweight. All studies of medium to high quality (Quality Assessment of Diagnostic Accuracy Studies score ≥8) published in English were included. Bivariate random-effects meta-analysis and hierarchical summary receiver operating characteristic curves were used. A total of 69 studies evaluated foot length or the circumference of the chest, (mid-upper) arm, or thigh (n = 8, 25, 30, and 6, respectively). Chest circumference and arm circumference had areas under the curve >0.9 (0.95 for both), pooled positive likelihood ratios >5 (8.7 and 10.3, respectively), and negative likelihood ratios <0.2 (0.13 and 0.17, respectively); thigh circumference and foot length were less accurate. There was no substantial difference between chest and arm circumference with respect to pooled sensitivity (0.88 vs. 0.84, P = 0.505), specificity (0.90 vs. 0.92, P = 0.565), or diagnostic odds ratio (67 vs. 60, P = 0.552). However, as compared with arm circumference, chest circumference showed greater clustering of observations on the hierarchical summary receiver operating characteristic curve and narrower 95% confidence and prediction regions. Chest circumference and arm circumference have similarly high, although not confirmative, accuracy in predicting low birthweight; however, chest circumference appears to be more precise.
Culp, E. Lynn
2017-01-01
This submission includes an Electricity Generation Summary, Maintenance Logs, Detailed Operations Data, Operating Cost Summary, and an Operations overview at the Paisley Oregon Geothermal Plant. Data uploaded for SVEC by Tom Williams, NREL
DOE Office of Scientific and Technical Information (OSTI.GOV)
Weber, E.R.
1983-09-01
The solar central receiver technology, site, and specific unit for repowering were selected in prior analyses and studies. The objectives of this preliminary design study were to: develop a solar central receiver repowering design for Saguaro that (1) has potential to be economically competitive with fossil fueled plants in near and long term applications, (2) has the greatest chance for completion without further government funding, (3) will further define technical and economic feasibility of a 66 MWe gross size plant that is adequate to meet the requirements for utility and industrial process heat applications, (4) can potentially be constructed andmore » operated within the next five years, and (5) incorporates solar central receiver technology and represents state-of-the-art development. This volume on the preliminary design includes the following sections: executive summary; introduction; changes from advanced conceptual design; preliminary design; system characteristics; economic analysis; and development plan.« less
NASA aviation safety reporting system
NASA Technical Reports Server (NTRS)
1977-01-01
During the third quarter of operation of the Aviation Safety Reporting System (ASRS), 1429 reports concerning aviation safety were received from pilots, air traffic controllers, and others in the national aviation system. Details of the administration and results of the program are discussed. The design and construction of the ASRS data base are briefly presented. Altitude deviations and potential aircraft conflicts associated with misunderstood clearances were studied and the results are discussed. Summary data regarding alert bulletins, examples of alert bulletins and responses to them, and a sample of deidentified ASRS reports are provided.
A 20 Ghz Depolarization Experiment Using the ATS-6 Satellite
NASA Technical Reports Server (NTRS)
Bostian, C. W.; Manus, E. A.; Marshall, R. E.; Pendrak, H. N.; Stutzman, W. L.; Wiley, P. H.; Kauffman, S. R.
1975-01-01
A depolarization experiment using the 20 GHz downlink from the ATS-6 satellite was described. The following subjects were covered: (1) an operational summary of the experiment, (2) a description of the equipment used with emphasis on improvements made to the signal processing receiver used with the ATS-5 satellite, (3) data on depolarization and attenuation in one snow storm and two rain storms at 45 deg elevation, (4) data on low angle propagation, (5) conclusions about depolarization on satellite paths, and (6) recommendations for the depolarization portion of the CTS experiment.
Belleli, Esther; Naccarella, Lucio; Pirotta, Marie
2013-12-01
Timeliness and quality of hospital discharge summaries are crucial for patient safety and efficient health service provision after discharge. We audited receipt rates, timeliness and the quality of discharge summaries for 49 admissions among 38 patients in an urban general practice. For missing discharge summaries, a hospital medical record search was performed. Discharge summaries were received for 92% of identified admissions; 73% were received within three days and 55% before the first post-discharge visit to the general practitioner (GP). Administrative information and clinical content, including diagnosis, treatment and follow-up plans, were well reported. However, information regarding tests, referrals and discharge medication was often missing; 57% of summaries were entirely typed and 13% had legibility issues. Completion rates were good but utility was compromised by delays, content omissions and formatting. Digital searching enables extraction of information from rich existing datasets contained in GP records for accurate measurement of discharge summary receipt rate and timing.
1992 Environmental monitoring report, Sandia National Laboratories, Albuquerque, New Mexico
DOE Office of Scientific and Technical Information (OSTI.GOV)
Culp, T.; Cox, W.; Hwang, H.
1993-09-01
This 1992 report contains monitoring data from routine radiological and nonradiological environmental surveillance activities. summaries of significant environmental compliance programs in progress, such as National Environmental Policy Act documentation, environmental permits, envirorunental restoration, and various waste management programs for Sandia National Laboratories in Albuquerque, New Mexico, are included. The maximum offsite dose impact was calculated to be 0.0034 millirem. The total population within a 50-mile radius of Sandia National Laboratories/New Mexico received an estimated collective dose of 0.019 person-rem during 1992 from the laboratories` operations. As in the previous year, the 1992 operations at Sandia National Laboratories/New Mexico had nomore » discernible impact on the general public or on the environment.« less
1991 Environmental monitoring report Sandia National Laboratories, Albuquerque, New Mexico
DOE Office of Scientific and Technical Information (OSTI.GOV)
Culp, T.; Cox, W.; Hwang, S.
1992-11-01
This 1991 report contains monitoring data from routine radiological and nonradiological environmental surveillance activities. Summaries of significant environmental compliance programs in progress such as National Environmental Policy Act (NEPA) documentation, environmental permits, environmental restoration (ER), and various waste management programs for Sandia National Laboratories in Albuquerque (SNL, Albuquerque) are included. The maximum offsite dose impact was calculated to be 1.3 {times} 10{sup {minus}3} mrem. The total population within a 50-mile radius of SNL, Albuquerque, received a collective dose of 0.53 person-rem during 1991 from SNL, Albuquerque, operations. As in the previous year, the 1991 operations at SNL, Albuquerque, had nomore » discernible impact on the general public or on the environment.« less
28 CFR 79.26 - Proof of medical condition.
Code of Federal Regulations, 2012 CFR
2012-07-01
... report; (C) Hematology summary or consultation report; (D) Medical oncology summary or consultation... report; (C) Hematology consultation or summary report; or (D) Medical oncology consultation or summary... discharge summary report; (C) Operative summary report; (D) Medical oncology summary or consultation report...
28 CFR 79.26 - Proof of medical condition.
Code of Federal Regulations, 2014 CFR
2014-07-01
... report; (C) Hematology summary or consultation report; (D) Medical oncology summary or consultation... report; (C) Hematology consultation or summary report; or (D) Medical oncology consultation or summary... discharge summary report; (C) Operative summary report; (D) Medical oncology summary or consultation report...
28 CFR 79.26 - Proof of medical condition.
Code of Federal Regulations, 2013 CFR
2013-07-01
... report; (C) Hematology summary or consultation report; (D) Medical oncology summary or consultation... report; (C) Hematology consultation or summary report; or (D) Medical oncology consultation or summary... discharge summary report; (C) Operative summary report; (D) Medical oncology summary or consultation report...
Li, Bin; Chen, Fei; Liu, Yi; Xu, Guokang
Total joint arthroplasty (TJA) has been one of the most beneficial interventions for treating patients suffering from joint disorders. However, peri-prosthetic joint infection (PJI) is a serious complication that often accompanies TJA and the diagnosis of PJI is remains difficult. Questions remain regarding whether certain biomarkers can be valuable in the diagnosis of PJI. We conducted our systematic review by searching PubMed, Embase, Web of Science, the Cochrane Library, and Science Direct with the key words "periprosthetic joint infection," "synovial fluid," and "α-defensin." Studies that provided sufficient data to construct 2 × 2 contingency tables were chosen based on inclusion and exclusion criteria. The quality of included studies was assessed according to the revised Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) criteria. The pooled sensitivity, specificity, and diagnostic odds ratio (DOR) were calculated for the included studies. The summary receiver operating characteristic (SROC) curve and the area under the summary receiver operating characteristic (AUSROC) were used to evaluate the overall diagnostic performance. Eight studies were included in this systematic review. Among them four articles were included in meta-analysis. A total of 421 participants were studied in the meta-analysis. The pooled sensitivity, specificity, and DOR were 0.98 (95% confidence interval [CI]: 0.94-1.00), 0.97 (95% CI: 0.95-0.99), and 1095.49 (95% CI: 283.68.58-4230.45), respectively. The AUSROC was 0.9949 (standard error [SE] 0.0095). Synovial fluid α-defensin is a biomarker of high sensitivity and specificity for the diagnosis of PJI.
ERIC Educational Resources Information Center
Deutsch, Morton
This paper is a summary report of a study of the effects of training in conflict resolution and cooperative learning in an alternative high school in New York City. Three of the school's four campuses participated, with Campus A receiving conflict resolution training, Campus C receiving cooperative learning training, and Campus B receiving…
Fluidized bed operations survey summary
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lombardi, C.
1996-12-31
A fluidized bed operations survey summary is presented. The survey contains information on: forced outage causes; forced outage concerns ranked numerically; 1996 boiler operation and maintenance (O&M) concerns; 1997 boiler O&M concerns; fluidized bed capacity factor results; and fluidized bed total outage time.
Licensed operating reactors: Status summary report, data as of December 31, 1995. Volume 20
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1996-06-01
The US Nuclear Regulatory Commission`s monthly summary of licensed nuclear power reactor data is based primarily on the operating data report submitted by licensees for each unit. This report is divided into two sections: the first contains summary highlights and the second contains data on each individual unit in commercial operation. Section 1 availability factors, capacity factors, and forced outage rates are simple arithmetic averages. Section 2 items in the cumulative column are generally as reported by the licensees and notes to the use of weighted averages and starting dates other than commercial operation are provided.
MSFC Skylab operations support summary
NASA Technical Reports Server (NTRS)
Martin, J. R.
1974-01-01
A summary of the actions and problems involved in preparing the Skylab-one vehicle is presented. The subjects discussed are: (1) flight operations support functions and organization, (2) launch operations and booster flight support functions and organization, (3) Skylab launch vehicle support teams, (4) Skylab orbital operations support performance analysis, (5) support manning and procedures, and (6) data support and facilities.
Shi, Xin-Yu; Liu, Yao; Gu, Xian-Min; Hao, Sheng-Yu; Wang, Yu-Hong; Yan, Di; Jiang, Shu-Juang
2016-08-01
The serum (1 → 3)-β-D-glucan (BG) assay has been approved for diagnosing invasive fungal diseases (IFDs). However, the performance of (1 → 3)-β-D-glucan assay in bronchoalveolar lavage (BAL) fluid is various among studies. The present study aimed to assess the accuracy of (1 → 3)-β-D-glucan assay in bronchoalveolar lavage fluid for the diagnosis of invasive fungal diseases by means of meta-analysis and systematic review of relevant studies. The sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), diagnostic odds ratio (OR) and a summary receiver-operating characteristic curve of BAL-BG for diagnosing invasive fungal diseases were pooled using meta-analysis. We also performed meta-regression analysis. A total of 838 patients (138 with proven or probable invasive fungal diseases), included in 6 studies, were analyzed. The pooled sensitivity, specificity, PLR, NLR and diagnostic odds ratio were 0.52 (95%CI, 0.38-0.53), 0.58 (95%CI, 0.55-0.61), 1.34 (95%CI, 1.08-1.66), 0.82 (95% CI, 0.63-1.07) and 1.71 (95%CI, 1.01-2.92) respectively. The area under the summary receiver operating characteristic curve, with 95% confidence intervals was 0.61 (95%CI, 0.67-0.55). The accuracy of (1 → 3)-β-D-glucan test in bronchoalveolar lavage fluid is marginal, so that the results should not be interpreted alone but can be used as a part of full assessment with clinical features, image findings and other laboratory results for the diagnosis of invasive fungal diseases. Copyright © 2016 Elsevier Ltd. All rights reserved.
Wan, Bing; Wang, Siqi; Tu, Mengqi; Wu, Bo; Han, Ping; Xu, Haibo
2017-03-01
The purpose of this meta-analysis was to evaluate the diagnostic accuracy of perfusion magnetic resonance imaging (MRI) as a method for differentiating glioma recurrence from pseudoprogression. The PubMed, Embase, Cochrane Library, and Chinese Biomedical databases were searched comprehensively for relevant studies up to August 3, 2016 according to specific inclusion and exclusion criteria. The quality of the included studies was assessed according to the quality assessment of diagnostic accuracy studies (QUADAS-2). After performing heterogeneity and threshold effect tests, pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratio were calculated. Publication bias was evaluated visually by a funnel plot and quantitatively using Deek funnel plot asymmetry test. The area under the summary receiver operating characteristic curve was calculated to demonstrate the diagnostic performance of perfusion MRI. Eleven studies covering 416 patients and 418 lesions were included in this meta-analysis. The pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratio were 0.88 (95% confidence interval [CI] 0.84-0.92), 0.77 (95% CI 0.69-0.84), 3.93 (95% CI 2.83-5.46), 0.16 (95% CI 0.11-0.22), and 27.17 (95% CI 14.96-49.35), respectively. The area under the summary receiver operating characteristic curve was 0.8899. There was no notable publication bias. Sensitivity analysis showed that the meta-analysis results were stable and credible. While perfusion MRI is not the ideal diagnostic method for differentiating glioma recurrence from pseudoprogression, it could improve diagnostic accuracy. Therefore, further research on combining perfusion MRI with other imaging modalities is warranted.
Chen, Yile; Tai, Qiang; Hong, Shaodong; Kong, Yuan; Shang, Yushu; Liang, Wenhua; Guo, Zhiyong; He, Xiaoshun
2012-11-15
The question of whether high pretransplantation soluble CD30 (sCD30) level can be a predictor of kidney transplant acute rejection (AR) is under debate. Herein, we performed a meta-analysis on the predictive efficacy of sCD30 for AR in renal transplantation. PubMed (1966-2012), EMBASE (1988-2012), and Web of Science (1986-2012) databases were searched for studies concerning the predictive efficacy of sCD30 for AR after kidney transplantation. After a careful review of eligible studies, sensitivity, specificity, and other measures of the accuracy of sCD30 were pooled. A summary receiver operating characteristic curve was used to represent the overall test performance. Twelve studies enrolling 2507 patients met the inclusion criteria. The pooled estimates for pretransplantation sCD30 in prediction of allograft rejection risk were poor, with a sensitivity of 0.70 (95% confidence interval (CI), 0.66-0.74), a specificity of 0.48 (95% CI, 0.46-0.50), a positive likelihood ratio of 1.35 (95% CI, 1.20-1.53), a negative likelihood ratio of 0.68 (95% CI, 0.55-0.84), and a diagnostic odds ratio of 2.07 (95% CI, 1.54-2.80). The area under curve of the summary receiver operating characteristic curve was 0.60, indicating poor overall accuracy of the serum sCD30 level in the prediction of patients at risk for AR. The results of the meta-analysis show that the accuracy of pretransplantation sCD30 for predicting posttransplantation AR was poor. Prospective studies are needed to clarify the usefulness of this test for identifying risks of AR in transplant recipients.
Orbital operation study. Volume 2: Interfacing activities analysis. Part 1: Introduction and summary
NASA Technical Reports Server (NTRS)
Anderson, N. R.
1972-01-01
The summary of the interfacing activity analyses for the orbital operations study is presented. The significant analyses are grouped into categories as follows: (1) structural and mechanical activity, (2) data management, and (3) support operations. Specific subjects concerning payload deployment, communications, rendezvous, and stationkeeping are discussed.
Geboy, Nicholas J.; Engle, Mark A.; Schroeder, Karl T.; Zupancic, John W.
2011-01-01
As part of a 5-year project on the impact of subsurface drip irrigation (SDI) application of coalbed-methane (CBM) produced waters, water samples were collected from the Headgate Draw SDI site in the Powder River Basin, Wyoming, USA. This research is part of a larger study to understand short- and long-term impacts on both soil and water quality from the beneficial use of CBM waters to grow forage crops through use of SDI. This document provides a summary of the context, sampling methodology, and quality assurance and quality control documentation of samples collected prior to and over the first year of SDI operation at the site (May 2008-October 2009). This report contains an associated database containing inorganic compositional data, water-quality criteria parameters, and calculated geochemical parameters for samples of groundwater, soil water, surface water, treated CBM waters, and as-received CBM waters collected at the Headgate Draw SDI site.
3D printing for soft robotics – a review
Gul, Jahan Zeb; Sajid, Memoon; Rehman, Muhammad Muqeet; Siddiqui, Ghayas Uddin; Shah, Imran; Kim, Kyung-Hwan; Lee, Jae-Wook; Choi, Kyung Hyun
2018-01-01
Abstract Soft robots have received an increasing attention due to their advantages of high flexibility and safety for human operators but the fabrication is a challenge. Recently, 3D printing has been used as a key technology to fabricate soft robots because of high quality and printing multiple materials at the same time. Functional soft materials are particularly well suited for soft robotics due to a wide range of stimulants and sensitive demonstration of large deformations, high motion complexities and varied multi-functionalities. This review comprises a detailed survey of 3D printing in soft robotics. The development of key 3D printing technologies and new materials along with composites for soft robotic applications is investigated. A brief summary of 3D-printed soft devices suitable for medical to industrial applications is also included. The growing research on both 3D printing and soft robotics needs a summary of the major reported studies and the authors believe that this review article serves the purpose. PMID:29707065
3D printing for soft robotics - a review.
Gul, Jahan Zeb; Sajid, Memoon; Rehman, Muhammad Muqeet; Siddiqui, Ghayas Uddin; Shah, Imran; Kim, Kyung-Hwan; Lee, Jae-Wook; Choi, Kyung Hyun
2018-01-01
Soft robots have received an increasing attention due to their advantages of high flexibility and safety for human operators but the fabrication is a challenge. Recently, 3D printing has been used as a key technology to fabricate soft robots because of high quality and printing multiple materials at the same time. Functional soft materials are particularly well suited for soft robotics due to a wide range of stimulants and sensitive demonstration of large deformations, high motion complexities and varied multi-functionalities. This review comprises a detailed survey of 3D printing in soft robotics. The development of key 3D printing technologies and new materials along with composites for soft robotic applications is investigated. A brief summary of 3D-printed soft devices suitable for medical to industrial applications is also included. The growing research on both 3D printing and soft robotics needs a summary of the major reported studies and the authors believe that this review article serves the purpose.
When Less Is More: Meaningful Learning from Visual and Verbal Summaries of Science Textbook Lessons.
ERIC Educational Resources Information Center
Mayer, Richard E.; And Others
1996-01-01
In 3 experiments, 163 college students who read a summary with a sequence of short captions with simple illustrations depicting steps in a process recalled the steps and solved transfer problems as well as or better than students who received the full text with a summary or alone. (SLD)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sittler, O.D.; Agogino, M.M.
1979-05-01
This project was undertaken to improve the data base for estimating solar energy influx in eastern New Mexico. A precision pyranometer station has been established at Eastern New Mexico University in Portales. A program of careful calibration and data management procedures is conducted to maintain high standards of precision and accuracy. Data from the first year of operation were used to upgrade insolation data of moderate accuracy which had been obtained at this site with an inexpensive pyranograph. Although not as accurate as the data expected from future years of operation of this station, these upgraded pyranograph measurements show thatmore » eastern New Mexico receives somewhat less solar energy than would be expected from published data. A detailed summary of these upgraded insolation data is included.« less
1990 Environmental Monitoring Report, Sandia National Laboratories, Albuquerque, New Mexico
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hwang, S.; Yeager, G.; Wolff, T.
1991-05-01
This 1990 report contains monitoring data from routine radiological and nonradiological environmental surveillance activities. Summaries of significant environmental compliance programs in progress such as National Environmental Policy Act (NEPA) documentation, environmental permits, environmental restoration, and various waste management programs for Sandia National Laboratories in Albuquerque (SNL, Albuquerque) are included. The maximum offsite dose impact was calculated to be 2.0 {times} 10{sup {minus}3} mrem. The total 50-mile population received a collective dose of 0.82 person-rem during 1990 from SNL, Albuquerque, operations. As in the previous year, the 1990 SNL operations had no adverse impact on the general public or on themore » environment. This report is prepared for the US Department of Energy in compliance with DOE Order 5400.1. 97 refs., 30 figs., 137 tabs.« less
Effect of discharge summary availability during post-discharge visits on hospital readmission.
van Walraven, Carl; Seth, Ratika; Austin, Peter C; Laupacis, Andreas
2002-03-01
To determine if the delivery of hospital discharge summaries to follow-up physicians decreases the risk of hospital readmission. Eight hundred eighty-eight patients discharged from a single hospital following treatment for an acute medical illness. Teaching hospital in a universal health-care system. We determined the date that each patient's discharge summary was printed and the physicians to whom it was sent. Summary receipt was confirmed by survey and phoning each physician's office. Each patient's hospital chart was reviewed to determine their acute and chronic medical conditions as well as their course in hospital. Using population-based administrative databases, all post-hospitalization visits were identified. For each of these visits, we determined whether the summary was available. Time to nonelective hospital readmission during 3 months following discharge. The discharge summary was available for only 568 of 4,639 outpatient visits (12.2%). Overall, 240 (27.0%) of patients were urgently readmitted to hospital. After adjusting for significant patient and hospitalization factors, we found a trend toward a decreased risk of readmission for patients who were seen in follow-up by a physician who had received a summary (relative risk 0.74, 95% confidence interval 0.50 to 1.11). The risk of rehospitalization may decrease when patients are assessed following discharge by physicians who have received the discharge summary. Further research is required to determine if better continuity of patient information improves patient outcomes.
Evaluation of Operator Radioprotection Using a New Injection Device during Vertebroplasty
Nguyen-Kim, L.; Fargeot, C.; Beaussier, H.; Payen, S.; Chiras, J.
2013-01-01
Summary This study aimed to evaluate the protection granted by a simple device (X'TENS®, Thiebaud, France) and to provide operators with information on the performance of this new device, which has not yet been assessed. Our assumption is that this device efficiently reduces the radiation dose to the operator. In a prospective clinical study, the radiation dose the operator's hand receives has been assessed using a specific sensor (UNFOR Instrument). Each patient included in the study was to receive at least two injections of cement during the procedure. Exposure was measured with and without the range extender. The data collected were then processed using a Wilcoxon matched pairs test. During 14 interventions, 20 vertebrae were treated with both procedures. Eleven women and three men were included. Seven patients underwent vertebroplasty for metastatic lesions and seven for osteoporotic lesions, bone fractures or vertebral compressions. The average injection time was 1.35 minutes with the device and 1.20 without (p=0.75). The dose to the hand per ml injected was 111.37 vs. 166.91 (p<0.05). Theoretically, the protection granted by the range extender depends on the length of the device. Our results are consistent with the inverse-square law. However, the variations in our results indicate that a proper and rigorous use is mandatory for the device to be effective. Given that radioprotection during fluoroscopy procedures is a frequently raised issue, the need for information for a safer practice increases likewise. PMID:23693040
Research and Technology Operating Plan Summary, Fiscal Year 1972 Research and Technology Program
NASA Technical Reports Server (NTRS)
1971-01-01
The NASA Research and Technology program for FY 1972 is presented. It is a compilation of the summary portions of each of the RTOPs (Research and Technology Operating Plan) used for management review and control of research currently in progress throughout NASA. The RTOP Summary is designed to facilitate communication and coordination among concerned technical personnel in government, in industry, and in universities.
Operation UPSHOT-KNOTHOLE. Operational Summary, Nevada Proving Grounds, 1 March - 9 June 1953
1982-08-01
EXTRACTED VERSION OPERATION UPSHOT-KNOTHOLE -- Operational Summary Nevada Proving Grounds ,* 1 March-9 June 1953 Headquarters Field Command Armed...Weapons Effects Tests 9. PERIORUMING 004CAWIZAY10ON AME ANO AOO1RESS 10. P140GRAM ELEMENPT, PROJECT, TASK AREA a 1114.01110 UNIT NUMBERS Headquarters Field ...process of preparation. Activities in prepara- tion for the operational period have been previously recorded in Field Commnand Histo y DO I "’* 1473
DOE Office of Scientific and Technical Information (OSTI.GOV)
Humphrey, J.A.C.
1982-01-01
A summary is provided of the first of three years of experimental and theoretical research on free-forced convection flows in cavity-type solar receivers. New experimental and theoretical results are presented and discussed. The implication of these findings, with respect to the future thrust of the research program, is clarified as well as is possible at the present time. Following various related conclusions a summary and tentative schedule of work projected for year two of research are presented.
Suh, Chong Hyun; Choi, Young Jun; Baek, Jung Hwan; Lee, Jeong Hyun
2017-01-01
To evaluate the diagnostic performance of shear wave elastography for malignant cervical lymph nodes. We searched the Ovid-MEDLINE and EMBASE databases for published studies regarding the use of shear wave elastography for diagnosing malignant cervical lymph nodes. The diagnostic performance of shear wave elastography was assessed using bivariate modelling and hierarchical summary receiver operating characteristic modelling. Meta-regression analysis and subgroup analysis according to acoustic radiation force impulse imaging (ARFI) and Supersonic shear imaging (SSI) were also performed. Eight eligible studies which included a total sample size of 481 patients with 647 cervical lymph nodes, were included. Shear wave elastography showed a summary sensitivity of 81 % (95 % CI: 72-88 %) and specificity of 85 % (95 % CI: 70-93 %). The results of meta-regression analysis revealed that the prevalence of malignant lymph nodes was a significant factor affecting study heterogeneity (p < .01). According to the subgroup analysis, the summary estimates of the sensitivity and specificity did not differ between ARFI and SSI (p = .93). Shear wave elastography is an acceptable imaging modality for diagnosing malignant cervical lymph nodes. We believe that both ARFI and SSI may have a complementary role for diagnosing malignant cervical lymph nodes. • Shear wave elastography is acceptable modality for diagnosing malignant cervical lymph nodes. • Shear wave elastography demonstrated summary sensitivity of 81 % and specificity of 85 %. • ARFI and SSI have complementary roles for diagnosing malignant cervical lymph nodes.
Elastography for the differentiation of benign and malignant liver lesions: a meta-analysis.
Ma, Xuelei; Zhan, Wenli; Zhang, Binglan; Wei, Benling; Wu, Xin; Zhou, Min; Liu, Lei; Li, Ping
2014-05-01
The objective of this paper was to evaluate the overall accuracy of elastography in the diagnosis of benign and malignant liver lesions by liver biopsy as the gold standard. Literature databases were searched. The studies which were related to evaluate the diagnostic value of elastography for differentiation in benign and malignant liver lesions in English or Chinese were included. The summary receiver operating characteristic (SROC) curve was performed, and the areas under the curve (AUC) were also calculated to present the accuracy of the elastography for the diagnosis of benign and malignant liver lesions. Six studies which included a total of 448 liver lesions in 384 patients were analyzed. The summary sensitivity and specificity of elastography for the differentiation of malignant liver lesions were 85% (95% CI, 80 to 89%) and 84% (95% CI, 80 to 88%), respectively. And the summary diagnostic odds ratio was 46.33 (95% CI, 15.22 to 141.02), and the SROC was 0.9328. Elastography has a high sensitivity and specificity differentiation for benign and malignant liver lesions. As a non-invasive method, it is promising to be applied to clinical practice. To estimate elastography objectively, a large, prospective, international, and multi-center study is still needed.
Optimal joint detection and estimation that maximizes ROC-type curves
Wunderlich, Adam; Goossens, Bart; Abbey, Craig K.
2017-01-01
Combined detection-estimation tasks are frequently encountered in medical imaging. Optimal methods for joint detection and estimation are of interest because they provide upper bounds on observer performance, and can potentially be utilized for imaging system optimization, evaluation of observer efficiency, and development of image formation algorithms. We present a unified Bayesian framework for decision rules that maximize receiver operating characteristic (ROC)-type summary curves, including ROC, localization ROC (LROC), estimation ROC (EROC), free-response ROC (FROC), alternative free-response ROC (AFROC), and exponentially-transformed FROC (EFROC) curves, succinctly summarizing previous results. The approach relies on an interpretation of ROC-type summary curves as plots of an expected utility versus an expected disutility (or penalty) for signal-present decisions. We propose a general utility structure that is flexible enough to encompass many ROC variants and yet sufficiently constrained to allow derivation of a linear expected utility equation that is similar to that for simple binary detection. We illustrate our theory with an example comparing decision strategies for joint detection-estimation of a known signal with unknown amplitude. In addition, building on insights from our utility framework, we propose new ROC-type summary curves and associated optimal decision rules for joint detection-estimation tasks with an unknown, potentially-multiple, number of signals in each observation. PMID:27093544
Optimal Joint Detection and Estimation That Maximizes ROC-Type Curves.
Wunderlich, Adam; Goossens, Bart; Abbey, Craig K
2016-09-01
Combined detection-estimation tasks are frequently encountered in medical imaging. Optimal methods for joint detection and estimation are of interest because they provide upper bounds on observer performance, and can potentially be utilized for imaging system optimization, evaluation of observer efficiency, and development of image formation algorithms. We present a unified Bayesian framework for decision rules that maximize receiver operating characteristic (ROC)-type summary curves, including ROC, localization ROC (LROC), estimation ROC (EROC), free-response ROC (FROC), alternative free-response ROC (AFROC), and exponentially-transformed FROC (EFROC) curves, succinctly summarizing previous results. The approach relies on an interpretation of ROC-type summary curves as plots of an expected utility versus an expected disutility (or penalty) for signal-present decisions. We propose a general utility structure that is flexible enough to encompass many ROC variants and yet sufficiently constrained to allow derivation of a linear expected utility equation that is similar to that for simple binary detection. We illustrate our theory with an example comparing decision strategies for joint detection-estimation of a known signal with unknown amplitude. In addition, building on insights from our utility framework, we propose new ROC-type summary curves and associated optimal decision rules for joint detection-estimation tasks with an unknown, potentially-multiple, number of signals in each observation.
DOT National Transportation Integrated Search
2005-12-15
The annual revision of the Waterborne : Transportation Lines of the United States : (WTLUS) contains summary information of : the vessel companies and their American : flag vessels operating or available for : operation on 31 December 2004 including ...
Evaluation of the Anaheim Advanced Traffic Control System Field Operational Test : executive summary
DOT National Transportation Integrated Search
1999-07-01
This Executive Summary provides an overview of the technical and institutional issues associated with the evaluation of the federally-sponsored Anaheim Advanced Traffic Control : System Field Operations Test. The primary FOT objective was the impleme...
Improving the accuracy of operation coding in surgical discharge summaries
Martinou, Eirini; Shouls, Genevieve; Betambeau, Nadine
2014-01-01
Procedural coding in surgical discharge summaries is extremely important; as well as communicating to healthcare staff which procedures have been performed, it also provides information that is used by the hospital's coding department. The OPCS code (Office of Population, Censuses and Surveys Classification of Surgical Operations and Procedures) is used to generate the tariff that allows the hospital to be reimbursed for the procedure. We felt that the OPCS coding on discharge summaries was often incorrect within our breast and endocrine surgery department. A baseline measurement over two months demonstrated that 32% of operations had been incorrectly coded, resulting in an incorrect tariff being applied and an estimated loss to the Trust of £17,000. We developed a simple but specific OPCS coding table in collaboration with the clinical coding team and breast surgeons that summarised all operations performed within our department. This table was disseminated across the team, specifically to the junior doctors who most frequently complete the discharge summaries. Re-audit showed 100% of operations were accurately coded, demonstrating the effectiveness of the coding table. We suggest that specifically designed coding tables be introduced across each surgical department to ensure accurate OPCS codes are used to produce better quality surgical discharge summaries and to ensure correct reimbursement to the Trust. PMID:26734286
DOT National Transportation Integrated Search
2014-05-01
This document is a summary of all responses the USDOT received from the Connected Vehicle Pilot Deployment Programs Request for Information (RFI) Notice put out by the Federal Highway Administration on 03/12/2014.
14 CFR 135.417 - Mechanical interruption summary report.
Code of Federal Regulations, 2011 CFR
2011-01-01
... OPERATING REQUIREMENTS: COMMUTER AND ON DEMAND OPERATIONS AND RULES GOVERNING PERSONS ON BOARD SUCH AIRCRAFT Maintenance, Preventive Maintenance, and Alterations § 135.417 Mechanical interruption summary report. Each... report of the following occurrences in multiengine aircraft for the preceding month to the certificate...
14 CFR 135.417 - Mechanical interruption summary report.
Code of Federal Regulations, 2012 CFR
2012-01-01
... OPERATING REQUIREMENTS: COMMUTER AND ON DEMAND OPERATIONS AND RULES GOVERNING PERSONS ON BOARD SUCH AIRCRAFT Maintenance, Preventive Maintenance, and Alterations § 135.417 Mechanical interruption summary report. Each... report of the following occurrences in multiengine aircraft for the preceding month to the certificate...
14 CFR 135.417 - Mechanical interruption summary report.
Code of Federal Regulations, 2013 CFR
2013-01-01
... OPERATING REQUIREMENTS: COMMUTER AND ON DEMAND OPERATIONS AND RULES GOVERNING PERSONS ON BOARD SUCH AIRCRAFT Maintenance, Preventive Maintenance, and Alterations § 135.417 Mechanical interruption summary report. Each... report of the following occurrences in multiengine aircraft for the preceding month to the certificate...
14 CFR 135.417 - Mechanical interruption summary report.
Code of Federal Regulations, 2014 CFR
2014-01-01
... OPERATING REQUIREMENTS: COMMUTER AND ON DEMAND OPERATIONS AND RULES GOVERNING PERSONS ON BOARD SUCH AIRCRAFT Maintenance, Preventive Maintenance, and Alterations § 135.417 Mechanical interruption summary report. Each... report of the following occurrences in multiengine aircraft for the preceding month to the certificate...
Steyerberg, Ewout W; Vedder, Moniek M; Leening, Maarten J G; Postmus, Douwe; D'Agostino, Ralph B; Van Calster, Ben; Pencina, Michael J
2015-07-01
New markers may improve prediction of diagnostic and prognostic outcomes. We aimed to review options for graphical display and summary measures to assess the predictive value of markers over standard, readily available predictors. We illustrated various approaches using previously published data on 3264 participants from the Framingham Heart Study, where 183 developed coronary heart disease (10-year risk 5.6%). We considered performance measures for the incremental value of adding HDL cholesterol to a prediction model. An initial assessment may consider statistical significance (HR = 0.65, 95% confidence interval 0.53 to 0.80; likelihood ratio p < 0.001), and distributions of predicted risks (densities or box plots) with various summary measures. A range of decision thresholds is considered in predictiveness and receiver operating characteristic curves, where the area under the curve (AUC) increased from 0.762 to 0.774 by adding HDL. We can furthermore focus on reclassification of participants with and without an event in a reclassification graph, with the continuous net reclassification improvement (NRI) as a summary measure. When we focus on one particular decision threshold, the changes in sensitivity and specificity are central. We propose a net reclassification risk graph, which allows us to focus on the number of reclassified persons and their event rates. Summary measures include the binary AUC, the two-category NRI, and decision analytic variants such as the net benefit (NB). Various graphs and summary measures can be used to assess the incremental predictive value of a marker. Important insights for impact on decision making are provided by a simple graph for the net reclassification risk. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Wunderlich, Adam; Abbey, Craig K
2013-11-01
Studies of lesion detectability are often carried out to evaluate medical imaging technology. For such studies, several approaches have been proposed to measure observer performance, such as the receiver operating characteristic (ROC), the localization ROC (LROC), the free-response ROC (FROC), the alternative free-response ROC (AFROC), and the exponentially transformed FROC (EFROC) paradigms. Therefore, an experimenter seeking to carry out such a study is confronted with an array of choices. Traditionally, arguments for different approaches have been made on the basis of practical considerations (statistical power, etc.) or the gross level of analysis (case-level or lesion-level). This article contends that a careful consideration of utility should form the rationale for matching the assessment paradigm to the clinical task of interest. In utility theory, task performance is commonly evaluated with total expected utility, which integrates the various event utilities against the probability of each event. To formalize the relationship between expected utility and the summary curve associated with each assessment paradigm, the concept of a "natural" utility structure is proposed. A natural utility structure is defined for a summary curve when the variables associated with the summary curve axes are sufficient for computing total expected utility, assuming that the disease prevalence is known. Natural utility structures for ROC, LROC, FROC, AFROC, and EFROC curves are introduced, clarifying how the utilities of correct and incorrect decisions are aggregated by summary curves. Further, conditions are given under which general utility structures for localization-based methodologies reduce to case-based assessment. Overall, the findings reveal how summary curves correspond to natural utility structures of diagnostic tasks, suggesting utility as a motivating principle for choosing an assessment paradigm.
Survey of State-of-the-Art LORAN-C Receivers
DOT National Transportation Integrated Search
1984-01-01
This report is a summary of the state-of-the-art in LORAN-C receiver design (April 1984). The data sources were manufacturers, designers, and trade literature. Every effort was made to accurately depict the status of receiver design activity in the m...
Communications Processor Operating System Study. Executive Summary,
1980-11-01
AD-A095 b36 ROME AIR DEVELOPMENT CENTER GRIFFISS AFB NY F/e 17/2 COMMUNICATIONS PROCESSOR OPERATING SYSTEM STUDY. EXECUTIVE SUMM—ETC(U) NOV 80 J...COMMUNICATIONS PROCESSOR OPERATING SYSTEM STUDY Julian Gitlih SPTIC ELECTE«^ FEfi 2 6 1981^ - E APPROVED FOR PUBLIC RELEASE; DISTRIBUTION UNLIMITED "a O...Subtitle) EXECUTIVE^SUMMARY 0F> COMMUNICATIONS PROCESSOR OPERATING SYSTEM $t - • >X W tdLl - ’•• • 7 AUTHORf«! ! , Julian
Summary report of journal operations, 2012.
2013-01-01
Presents the summary reports of American Psychological Association journal operations (compiled from the 2012 annual reports of the Council of Editors and from Central Office records) and Division journal operations (compiled from the 2012 annual reports of the Division journal editors). The information provided includes number of manuscripts, printed pages, and print subscriptions per journal. (PsycINFO Database Record (c) 2013 APA, all rights reserved).
Effect of Discharge Summary Availability During Post-discharge Visits on Hospital Readmission
van Walraven, Carl; Seth, Ratika; Austin, Peter C; Laupacis, Andreas
2002-01-01
OBJECTIVE To determine if the delivery of hospital discharge summaries to follow-up physicians decreases the risk of hospital readmission. SUBJECTS Eight hundred eighty-eight patients discharged from a single hospital following treatment for an acute medical illness. SETTING Teaching hospital in a universal health-care system. DESIGN We determined the date that each patient's discharge summary was printed and the physicians to whom it was sent. Summary receipt was confirmed by survey and phoning each physician's office. Each patient's hospital chart was reviewed to determine their acute and chronic medical conditions as well as their course in hospital. Using population-based administrative databases, all post-hospitalization visits were identified. For each of these visits, we determined whether the summary was available. MAIN OUTCOME MEASURES Time to nonelective hospital readmission during 3 months following discharge. RESULTS The discharge summary was available for only 568 of 4,639 outpatient visits (12.2%). Overall, 240 (27.0%) of patients were urgently readmitted to hospital. After adjusting for significant patient and hospitalization factors, we found a trend toward a decreased risk of readmission for patients who were seen in follow-up by a physician who had received a summary (relative risk 0.74, 95% confidence interval 0.50 to 1.11). CONCLUSIONS The risk of rehospitalization may decrease when patients are assessed following discharge by physicians who have received the discharge summary. Further research is required to determine if better continuity of patient information improves patient outcomes. PMID:11929504
Neumann, Ignacio; Alonso-Coello, Pablo; Vandvik, Per Olav; Agoritsas, Thomas; Mas, Gemma; Akl, Elie A; Brignardello-Petersen, Romina; Emparanza, Jose; McCullagh, Lauren; De Sitio, Catherine; McGinn, Thomas; Almodaimegh, Hind; Almodaimegh, Khalid; Rivera, Solange; Rojas, Luis; Stirnemann, Jérôme; Irani, Jihad; Hlais, Sani; Mustafa, Reem; Bdair, Fadi; Aly, Abdelrahman; Kristiansen, Annette; Izcovich, Ariel; Ramirez, Anggie; Brozek, Jan; Guyatt, Gordon; Schünemann, Holger J
2018-03-09
Evidence-based clinical practice guidelines provide recommendations to assist clinicians in decision-making and to reduce the gap between best current research evidence and clinical practice. However, some argue that providing pre-appraised evidence summaries alone, rather than recommendations, is more appropriate. To evaluate clinicians' preferences, understanding of the evidence and intended course of action in response to evidence summaries with and without recommendations. We included practicing clinicians attending educational sessions across 10 countries. Clinicians were randomized to receive relevant clinical scenarios supported by research evidence of low or very-low certainty, and accompanied by either strong or weak recommendations developed with the GRADE system. Within each group, participants were further randomized to receive the recommendation plus the corresponding evidence summary or the evidence summary alone. We evaluated participants' preferences and understanding for the presentation strategy as well as their intended course of action. 189/219 (86%) and 201/248 (81%) participants preferred having recommendations accompanying evidence summaries for both strong and weak recommendations, respectively. Across all scenarios less than half of participants correctly interpreted information provided in the evidences summaries (e.g. estimates of effect, certainty in the research evidence). Presence of a recommendation resulted in a more appropriate intended course of action for two scenarios involving strong recommendations. Evidence summaries alone are not enough to impact clinicians' course of action. Clinicians clearly prefer having recommendations accompanying evidence summaries in the context of low or very-low certainty of evidence (Trial registration NCT02006017). Copyright © 2018 Elsevier Inc. All rights reserved.
12 CFR 908.51 - Summary disposition.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 12 Banks and Banking 7 2010-01-01 2010-01-01 false Summary disposition. 908.51 Section 908.51... OPERATIONS RULES OF PRACTICE AND PROCEDURE IN HEARINGS ON THE RECORD Pre-Hearing Proceedings § 908.51 Summary... order granting a motion for summary disposition if the undisputed pleaded facts, admissions, affidavits...
Empirical evidence of the importance of comparative studies of diagnostic test accuracy.
Takwoingi, Yemisi; Leeflang, Mariska M G; Deeks, Jonathan J
2013-04-02
Systematic reviews that "compare" the accuracy of 2 or more tests often include different sets of studies for each test. To investigate the availability of direct comparative studies of test accuracy and to assess whether summary estimates of accuracy differ between meta-analyses of noncomparative and comparative studies. Systematic reviews in any language from the Database of Abstracts of Reviews of Effects and the Cochrane Database of Systematic Reviews from 1994 to October 2012. 1 of 2 assessors selected reviews that evaluated at least 2 tests and identified meta-analyses that included both noncomparative studies and comparative studies. 1 of 3 assessors extracted data about review and study characteristics and test performance. 248 reviews compared test accuracy; of the 6915 studies, 2113 (31%) were comparative. Thirty-six reviews (with 52 meta-analyses) had adequate studies to compare results of noncomparative and comparative studies by using a hierarchical summary receiver-operating characteristic meta-regression model for each test comparison. In 10 meta-analyses, noncomparative studies ranked tests in the opposite order of comparative studies. A total of 25 meta-analyses showed more than a 2-fold discrepancy in the relative diagnostic odds ratio between noncomparative and comparative studies. Differences in accuracy estimates between noncomparative and comparative studies were greater than expected by chance (P < 0.001). A paucity of comparative studies limited exploration of direction in bias. Evidence derived from noncomparative studies often differs from that derived from comparative studies. Robustly designed studies in which all patients receive all tests or are randomly assigned to receive one or other of the tests should be more routinely undertaken and are preferred for evidence to guide test selection. National Institute for Health Research (United Kingdom).
Research and Technology Operating Plan Summary: Fiscal Year 1973 Research and Technology Program
NASA Technical Reports Server (NTRS)
1972-01-01
Abstracts are presented of each of the Research and Technology Operating Plans (RTOP) used for management review and control of research currently in progress throughout NASA. This RTOP Summary is designed to facilitate communication and coordination among concerned technical personnel in government, industry, and universities. The summary is arranged in five sections consisting of citations and abstracts of the RTOPs and subject, technical monitor, responsible NASA organization, and RTOP number indexes.
Inertial Navigation System Standardized Software Development. Volume 1. Introduction and Summary
1976-06-01
the Loran receiver, the Tacan receiver, the Omega receiver, the satelite based instrumentation, the multimode radar, the star tracker and the visual...accelerometer scale factor, and the barometric altimeter bias. The accuracy (1o values) of typical navigation-aid measurements (other than satelite derived
78 FR 54686 - Notice of Permit Applications Received under the Antarctic Conservation Act of 1978
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-05
... NATIONAL SCIENCE FOUNDATION Notice of Permit Applications Received under the Antarctic Conservation Act of 1978 AGENCY: National Science Foundation. ACTION: Notice of Permit Applications Received under the Antarctic Conservation Act of 1978. SUMMARY: The National Science Foundation (NSF) is required...
77 FR 60477 - Notice of Permit Applications Received Under the Antarctic Conservation Act of 1978
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-03
... NATIONAL SCIENCE FOUNDATION Notice of Permit Applications Received Under the Antarctic Conservation Act of 1978 AGENCY: National Science Foundation. ACTION: Notice of permit applications received under the Antarctic Conservation Act of 1978, Public Law 95-541. SUMMARY: The National Science...
78 FR 60321 - Notice of Permit Applications Received Under the Antarctic Conservation Act of 1978
Federal Register 2010, 2011, 2012, 2013, 2014
2013-10-01
... NATIONAL SCIENCE FOUNDATION Notice of Permit Applications Received Under the Antarctic Conservation Act of 1978 AGENCY: National Science Foundation. ACTION: Notice of Permit Applications Received under the Antarctic Conservation Act of 1978, Public Law 95-541. SUMMARY: The National Science...
77 FR 23766 - Notice of Permit Applications Received Under the Antarctic Conservation Act of 1978
Federal Register 2010, 2011, 2012, 2013, 2014
2012-04-20
... NATIONAL SCIENCE FOUNDATION Notice of Permit Applications Received Under the Antarctic Conservation Act of 1978 AGENCY: National Science Foundation. ACTION: Notice of Permit Applications Received under the Antarctic Conservation Act of 1978, Public Law 95-541. SUMMARY: The National Science...
14 CFR 121.705 - Mechanical interruption summary report.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Mechanical interruption summary report. 121... OPERATING REQUIREMENTS: DOMESTIC, FLAG, AND SUPPLEMENTAL OPERATIONS Records and Reports § 121.705 Mechanical... known or suspected mechanical difficulties or malfunctions that are not required to be reported under...
1995 solid waste 30-year characteristics volume summary
DOE Office of Scientific and Technical Information (OSTI.GOV)
Templeton, K.J.; DeForest, T.J.; Rice, G.I.
1995-10-01
The Hanford Site has been designated by the US Department of Energy (DOE) to store, treat, and dispose of solid waste received from both onsite and offsite generators. This waste is currently or planned to be generated from ongoing operations, maintenance and deactivation activities, decontamination and decommissioning (D&D) of facilities, and environmental restoration (ER) activities. This document, prepared by Pacific Northwest Laboratory (PNL) under the direction of Westinghouse Hanford Company (WHC), describes the characteristics of the waste to be shipped to Hanford`s SWOC. The physical waste forms and hazardous constituents are described for the low-level mixed waste (LLMW) and themore » transuranic - transuranic mixed waste (TW{underscore}TRUM).« less
LSCA Final Reports: Second Series.
ERIC Educational Resources Information Center
Clark, Collin, Ed.
This document includes final summary reports from recent federally funded Library Services and Construction Act (LSCA) demonstration projects in California. While some projects reported at length and others provided the bare facts, reports are excerpted but published as received, without editing beyond a uniform first page. The Summary Report Form…
Sortie laboratory, phase B technical summary. [design and operational requirements
NASA Technical Reports Server (NTRS)
1973-01-01
The design and operational requirements which evolved from Sortie Lab (SL) analysis are summarized. A source of requirements for systems is given along with experimental support for the SL, baseline. Basic design data covered include: configuration definition, mission analysis, experimental integration, safety, and logistics. A technical summary outlines characteristics which reflect the influence of the growth in SL capability and the results of the mission and operational analysis. Each of the selected areas is described in terms of objectives, equipment, operational concept, and support requirements.
Licensed operating reactors: Status summary report data as of December 31, 1991. Volume 16
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1992-03-01
The Nuclear Regulatory Commission`s annual summary of licensed nuclear power reactor data is based primarily on the report of operating data submitted by licensees for each unit for the month of December because that report contains data for the month of December, the year to date (in this case calendar year 1991) and cumulative data, usually from the date of commercial operation. The data is not independently verified, but various computer checks are made. The report is divided into two sections. The first contains summary highlights and the second contains data on each individual unit in commercial operation. Section 1more » capacity and availability factors are simple arithmetic averages. Section 2 items in the cumulative column are generally as reported by the licensee and notes as to the use of weighted averages and starting dates other than commercial operation are provided.« less
Licensed operating reactors. Status summary report data as of 12-31-94: Volume 19
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1995-04-01
The Nuclear Regulatory Commission`s annual summary of licensed nuclear power reactor data is based primarily on the report of operating data submitted by licensees for each unit for the month of December because that report contains data for the month of December, the year to date (in this case calendar year 1994) and cumulative data, usually from the date of commercial operation. The data is not independently verified, but various computer checks are made. The report is divided into two sections. The first contains summary highlights and the second contains data on each individual unit in commercial operation. Section 1more » capacity and availability factors are simple arithmetic averages. Section 2 items in the cumulative column are generally as reported by the licensee and notes as to the use of weighted averages and starting dates other than commercial operation are provided.« less
NASA Technical Reports Server (NTRS)
1974-01-01
Background information is provided which emphasizes the philosophy behind analytical techniques used in the business risk and value of operations in space (BRAVO) study. The focus of the summary is on the general approach, operation of the procedures, and the status of the study. For Vol. 1, see N74-12493; for Vol. 2, see N74-14530.
2012-01-01
Background The aspartate aminotransferase-to-platelet ratio index (APRI), a tool with limited expense and widespread availability, is a promising noninvasive alternative to liver biopsy for detecting hepatic fibrosis. The objective of this study was to systematically review the performance of the APRI in predicting significant fibrosis and cirrhosis in hepatitis B-related fibrosis. Methods Areas under summary receiver operating characteristic curves (AUROC), sensitivity and specificity were used to examine the accuracy of the APRI for the diagnosis of hepatitis B-related significant fibrosis and cirrhosis. Heterogeneity was explored using meta-regression. Results Nine studies were included in this meta-analysis (n = 1,798). Prevalence of significant fibrosis and cirrhosis were 53.1% and 13.5%, respectively. The summary AUCs of the APRI for significant fibrosis and cirrhosis were 0.79 and 0.75, respectively. For significant fibrosis, an APRI threshold of 0.5 was 84% sensitive and 41% specific. At the cutoff of 1.5, the summary sensitivity and specificity were 49% and 84%, respectively. For cirrhosis, an APRI threshold of 1.0-1.5 was 54% sensitive and 78% specific. At the cutoff of 2.0, the summary sensitivity and specificity were 28% and 87%, respectively. Meta-regression analysis indicated that the APRI accuracy for both significant fibrosis and cirrhosis was affected by histological classification systems, but not influenced by the interval between Biopsy & APRI or blind biopsy. Conclusion Our meta-analysis suggests that APRI show limited value in identifying hepatitis B-related significant fibrosis and cirrhosis. PMID:22333407
Correlation of the summary method with learning styles.
Sarikcioglu, Levent; Senol, Yesim; Yildirim, Fatos B; Hizay, Arzu
2011-09-01
The summary is the last part of the lesson but one of the most important. We aimed to study the relationship between the preference of the summary method (video demonstration, question-answer, or brief review of slides) and learning styles. A total of 131 students were included in the present study. An inventory was prepared to understand the students' learning styles, and a satisfaction questionnaire was provided to determine the summary method selection. The questionnaire and inventory were collected and analyzed. A comparison of the data revealed that the summary method with video demonstration received the highest score among all the methods tested. Additionally, there were no significant differences between learning styles and summary method with video demonstration. We suggest that such a summary method should be incorporated into neuroanatomy lessons. Since anatomy has a large amount of visual material, we think that it is ideally suited for this summary method.
77 FR 65763 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-30
... seeking relief from specified requirements of 14 CFR. The purpose of this notice is to improve the public's awareness of, and participation in, this aspect of the FAA's regulatory activities. Neither publication of this notice nor the inclusion or omission of information in the summary is intended to affect...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-08-07
... NATIONAL SCIENCE FOUNDATION Notice of Permit Applications Received Under the Antarctic... Applications Received Under the Antarctic Conservation Act of 1978, Pub. L. 95-541. SUMMARY: The National... activities regulated under the Antarctic Conservation Act of 1978. NSF has published regulations under the...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-05-03
... received many applications and is still considering all applications received to date, the Agency is... broader applicant pool to reflect greater ethnic, gender, and industry diversity. The requirements for... following materials: (1) Resume, (2) personal statement of interest, including a summary of how the nominee...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-06-29
... generating invoices and receiving reports. TEDS is an accepted system for processing payment requests for... follows: A. Summary of Significant Changes Changes to the proposed rule to clarify language were made at... receive payment requests and receiving reports and clarify language and to clarify instructions for...
75 FR 70965 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2010-11-19
... rulemaking Web site: Go to http:[sol][sol]www.regulations.gov and follow the instructions for sending your.... Privacy: We will post all comments we receive, without change, to http:[sol][sol]www.regulations.gov... 19477-78). Docket: To read background documents or comments received, go to http:[sol][sol]www...
Nattabi, Haliimah A; Sharif, Norhafidzah M; Yahya, Noorazrul; Ahmad, Rozilawati; Mohamad, Mazlyfarina; Zaki, Faizah M; Yusoff, Ahmad N
2017-10-17
This study is a dedicated 2D-shear wave elastography (2D-SWE) review aimed at systematically eliciting up-to-date evidence of its clinical value in differential diagnosis of benign and malignant thyroid nodules. PubMed, Web of Science, and Scopus databases were searched for studies assessing the diagnostic value of 2D-SWE for thyroid malignancy risk stratification published until December 2016. The retrieved titles and abstracts were screened and evaluated according to the predefined inclusion and exclusion criteria. Methodological quality of the studies was assessed using the Quality Assessment of Studies of Diagnostic Accuracy included in Systematic Review 2 (QUADAS-2) tool. Extracted 2D-SWE diagnostic performance data were meta-analyzed to assess the summary sensitivity, specificity, and area under the receiver operating characteristic curve. After stepwise review, 14 studies in which 2D-SWE was used to evaluate 2851 thyroid nodules (1092 malignant, 1759 benign) from 2139 patients were selected for the current study. Study quality on QUADAS-2 assessment was moderate to high. The summary sensitivity, specificity and area under the receiver operating characteristic curve of 2D-SWE for differential diagnosis of benign and malignant thyroid nodules were 0.66 (95% confidence interval [CI]: 0.64-0.69), 0.78 (CI: 0.76-0.80), and 0.851 (Q* = 0.85), respectively. The pooled diagnostic odds ratio, negative likelihood ratio, and positive likelihood ratio were 12.73 (CI: 8.80-18.43), 0.31 (CI: 0.22-0.44), and 3.87 (CI: 2.83-5.29), respectively. Diagnostic performance of quantitative 2D-SWE for malignancy risk stratification of thyroid nodules is suboptimal with mediocre sensitivity and specificity, contrary to earlier reports of excellence. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.
CRITICAL EXPERIMENT TANK (CET) REACTOR HAZARDS SUMMARY
DOE Office of Scientific and Technical Information (OSTI.GOV)
Becar, N.J.; Kunze, J.F.; Pincock, G..D.
1961-03-31
The Critical Experiment Tank (CET) reactor assembly, the associated systems, and the Low Power Test Facility in which the reactor is to be operated are described. An evaluation and summary of the hazards associated with the operation of the CET reactor in the LPTF at the ldsho Test Station are also presented. (auth)
Washington State Community College Operating Budget, 1985-87. Management Summary.
ERIC Educational Resources Information Center
Washington State Board for Community Coll. Education, Olympia.
A summary is presented of the 1985-87 community college operating budget request for the Washington State Community colleges, along with a description of the policy considerations inherent in the request and the anticipated effect of the request on community college programs. The philosophy and objectives underpinning the budget request are…
Financial Aid as a Service. A Review of Operations. Summary Report.
ERIC Educational Resources Information Center
Adams, Judith
This review presents a summary of five reports resulting from several studies of Financial Aid Office (FAO) operations at Macomb Community College (MCC) in Michigan designed to determine how services were rendered or perceived. The first report presents findings from the literature search evaluation. An extensive search revealed few published…
The Sonic Altimeter for Aircraft
NASA Technical Reports Server (NTRS)
Draper, C S
1937-01-01
Discussed here are results already achieved with sonic altimeters in light of the theoretical possibilities of such instruments. From the information gained in this investigation, a procedure is outlined to determine whether or not a further development program is justified by the value of the sonic altimeter as an aircraft instrument. The information available in the literature is reviewed and condensed into a summary of sonic altimeter developments. Various methods of receiving the echo and timing the interval between the signal and the echo are considered. A theoretical discussion is given of sonic altimeter errors due to uncertainties in timing, variations in sound velocity, aircraft speed, location of the sending and receiving units, and inclinations of the flight path with respect to the ground surface. Plots are included which summarize the results in each case. An analysis is given of the effect of an inclined flight path on the frequency of the echo. A brief study of the acoustical phases of the sonic altimeter problem is carried through. The results of this analysis are used to predict approximately the maximum operating altitudes of a reasonably designed sonic altimeter under very good and very bad conditions. A final comparison is made between the estimated and experimental maximum operating altitudes which shows good agreement where quantitative information is available.
A Comparison of RF-DNA Fingerprinting Using High/Low Value Receivers with ZigBee Devices
2014-03-27
99) Device Classification using Hybrid Cross-Receiver model and USRP only testing . 54 V. Conclusion This chapter provides a summary of reseach ...Finally, when developing a Hybrid Cross-Receiver model using fingerprints from both receivers, testing with PXIe-only fingerprints proved to be the most...22 3.2 Post -Collection Processing . . . . . . . . . . . . . . . . . . . . . . . . . . 25 3.2.1 Burst Detection
El Shayeb, Mohamed; Topfer, Leigh-Ann; Stafinski, Tania; Pawluk, Lawrence; Menon, Devidas
2014-01-01
Background: Greater awareness of sleep-disordered breathing and rising obesity rates have fueled demand for sleep studies. Sleep testing using level 3 portable devices may expedite diagnosis and reduce the costs associated with level 1 in-laboratory polysomnography. We sought to assess the diagnostic accuracy of level 3 testing compared with level 1 testing and to identify the appropriate patient population for each test. Methods: We conducted a systematic review and meta-analysis of comparative studies of level 3 versus level 1 sleep tests in adults with suspected sleep-disordered breathing. We searched 3 research databases and grey literature sources for studies that reported on diagnostic accuracy parameters or disease management after diagnosis. Two reviewers screened the search results, selected potentially relevant studies and extracted data. We used a bivariate mixed-effects binary regression model to estimate summary diagnostic accuracy parameters. Results: We included 59 studies involving a total of 5026 evaluable patients (mostly patients suspected of having obstructive sleep apnea). Of these, 19 studies were included in the meta-analysis. The estimated area under the receiver operating characteristics curve was high, ranging between 0.85 and 0.99 across different levels of disease severity. Summary sensitivity ranged between 0.79 and 0.97, and summary specificity ranged between 0.60 and 0.93 across different apnea–hypopnea cut-offs. We saw no significant difference in the clinical management parameters between patients who underwent either test to receive their diagnosis. Interpretation: Level 3 portable devices showed good diagnostic performance compared with level 1 sleep tests in adult patients with a high pretest probability of moderate to severe obstructive sleep apnea and no unstable comorbidities. For patients suspected of having other types of sleep-disordered breathing or sleep disorders not related to breathing, level 1 testing remains the reference standard. PMID:24218531
Optimization of MLS receivers for multipath environments
NASA Technical Reports Server (NTRS)
Mcalpine, G. A.; Highfill, J. H., III
1979-01-01
The angle tracking problems in microwave landing system receivers along with a receiver design capable of optimal performance in the multipath environments found in air terminal areas were studied. Included were various theoretical and evaluative studies like: (1) signal model development; (2) derivation of optimal receiver structures; and (3) development and use of computer simulations for receiver algorithm evaluation. The development of an experimental receiver for flight testing is presented. An overview of the work and summary of principal results and conclusions are reported.
Space Operations Center system analysis study extension. Volume 1: Executive summary
NASA Technical Reports Server (NTRS)
1982-01-01
The analysis fo Space Operations Center (SOC) systems is summarized. Design considerations, configurations of the manned orbital space station, planned operational and research missions, and subsystem tradeoffs are considered. Integration into the space transportation system is discussed. A modular design concept permitting growth of the SOC as its functions are expanded is described. Additional considerations are special requirements for habitat modules, design modifications needed to operate in geosynchronous orbits, and use of the external tank for cryogenic propellant storage or as a pressurized hangar. A cost summary is presented.
Product Operations Status Summary Metrics
NASA Technical Reports Server (NTRS)
Takagi, Atsuya; Toole, Nicholas
2010-01-01
The Product Operations Status Summary Metrics (POSSUM) computer program provides a readable view into the state of the Phoenix Operations Product Generation Subsystem (OPGS) data pipeline. POSSUM provides a user interface that can search the data store, collect product metadata, and display the results in an easily-readable layout. It was designed with flexibility in mind for support in future missions. Flexibility over various data store hierarchies is provided through the disk-searching facilities of Marsviewer. This is a proven program that has been in operational use since the first day of the Phoenix mission.
Compendium of Executive Summaries from the Maglev System Concept Definition. Final Reports.
1993-03-01
This report contains the Executive Summaries from the four System Concept Definition (SCD) studies awarded under the National Maglev Initiative...These summaries present the technical feasibility, performance, capital, operating and maintenance costs for a maglev system that would be available by
19 CFR 142.22 - Application for special permit for immediate delivery.
Code of Federal Regulations, 2013 CFR
2013-04-01
... this chapter) have successfully been received by CBP via the Automated Broker Interface; an entry summary for warehouse; or an entry summary for entry temporarily under bond, which may be filed in any of the circumstances under § 142.21 of this part except for merchandise released from warehouse under...
19 CFR 142.22 - Application for special permit for immediate delivery.
Code of Federal Regulations, 2014 CFR
2014-04-01
... this chapter) have successfully been received by CBP via the Automated Broker Interface; an entry summary for warehouse; or an entry summary for entry temporarily under bond, which may be filed in any of the circumstances under § 142.21 of this part except for merchandise released from warehouse under...
19 CFR 142.22 - Application for special permit for immediate delivery.
Code of Federal Regulations, 2010 CFR
2010-04-01
... this chapter) have successfully been received by CBP via the Automated Broker Interface; an entry summary for warehouse; or an entry summary for entry temporarily under bond, which may be filed in any of the circumstances under § 142.21 of this part except for merchandise released from warehouse under...
19 CFR 142.22 - Application for special permit for immediate delivery.
Code of Federal Regulations, 2012 CFR
2012-04-01
... this chapter) have successfully been received by CBP via the Automated Broker Interface; an entry summary for warehouse; or an entry summary for entry temporarily under bond, which may be filed in any of the circumstances under § 142.21 of this part except for merchandise released from warehouse under...
19 CFR 142.22 - Application for special permit for immediate delivery.
Code of Federal Regulations, 2011 CFR
2011-04-01
... this chapter) have successfully been received by CBP via the Automated Broker Interface; an entry summary for warehouse; or an entry summary for entry temporarily under bond, which may be filed in any of the circumstances under § 142.21 of this part except for merchandise released from warehouse under...
The Effects of a Summary Writing Strategy on the Literacy Skills of Adolescents with Disabilities
ERIC Educational Resources Information Center
Asaro-Saddler, Kristie; Muir-Knox, Haley; Meredith, Holly
2018-01-01
Many adolescents, particularly adolescents with disabilities, have difficulty with literacy tasks such as reading and writing. Yet research has found that when students with disabilities receive appropriate instruction, they typically are able to improve their overall writing outcomes. This study explored the effectiveness of a summary writing…
75 FR 2925 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2010-01-19
... petitioner seeks relief from the requirements of fuel-tank structural lightning protection for its EMB-135BJ... seeking relief from specified requirements of 14 CFR. The purpose of this notice is to improve the public... publication of this notice nor the inclusion or omission of information in the summary is intended to affect...
Summary of Key Operating Statistics: Data Collected from the 2009 Annual Institutional Report
ERIC Educational Resources Information Center
Accrediting Council for Independent Colleges and Schools, 2010
2010-01-01
The Accrediting Council for Independent Colleges and Schools (ACICS) provides the Summary of Key Operating Statistics (KOS) as an annual review of the performance and key measurements of the more than 800 private post-secondary institutions we accredit. This edition of the KOS contains information based on the 2009 Annual Institutional Reports…
Analysis of 2000 Financial Forecasts and Annual Operating Statements. Report.
ERIC Educational Resources Information Center
Higher Education Funding Council for England, Bristol.
This report provides a summary of financial projections for the higher education sector in England covering 1999-2000 to 2003-2004 and a summary of the sector's annual operating statements for 1999-2000 and 2000-2001. It is based on information provided by higher education institutions in July 2000. These forecasts were prepared before the outcome…
Sommerich, Carolyn M; Lavender, Steven A; Radin Umar, Radin Zaid; Le, Peter; Mehta, Jay; Ko, Pei-Ling; Farfan, Rafael; Dutt, Mohini; Park, SangHyun
2012-01-01
Effects of ambulance cot design features (handle design and leg folding mechanism) were evaluated. Experienced ambulance workers performed tasks simulating loading and unloading a cot to and from an ambulance, and a cot raising task. Muscle activity, ratings of perceived exertion, and performance style were significantly affected by cot condition (p < 0.05). Erector Spinae activity was significantly less when using Cot-2's stretcher-style handles. Shoulder muscle activity was significantly less when using Cot-2's loop handle. During loading and unloading, operators allowed the cot to support its own weight most often with Cot-2's stretcher-style handles. Preference for Cot-2 (either handles) over Cot-1 (with loop handle) was consistent across tasks. Handle effects were influenced by operator stature; taller participants received more benefit from Cot-2's stretcher-style handles; shoulder muscles' demands were greater for shorter participants due to handle location. Providing handle options and automatic leg folding/unfolding operation can reduce cot operator's effort and physical strain. Practitioner Summary: Paramedics frequently incur musculoskeletal injuries associated with patient-handling tasks. A controlled experiment was conducted to assess effects of ambulance cot design features on physical stress of operators, as seen through muscle activity and operator's perceptions. Differences between cots were found, signalling that intentional design can reduce operator's physical stress.
Tropical Rainfall Measurement Mission (TRMM) Operation Summary
NASA Technical Reports Server (NTRS)
Nio, Tomomi; Saito, Susumu; Stocker, Erich; Pawloski, James H.; Murayama, Yoshifumi; Ohata, Takeshi
2015-01-01
The Tropical Rainfall Measurement Mission (TRMM) is a joint U.S. and Japan mission to observe tropical rainfall, which was launched by H-II No. 6 from Tanegashima in Japan at 6:27 JST on November 28, 1997. After the two-month commissioning of TRMM satellite and instruments, the original nominal mission lifetime was three years. In fact, the operations has continued for approximately 17.5 years. This paper provides a summary of the long term operations of TRMM.
Operation of Reliability Analysis Center (FY88)
1989-10-01
4.1 Current Projects 16 4.2 Completed Projects 22 6.0 FINANCIAL SUMMARY FY 23 7.0 INFORMATION FROM IAC USERS 24 7.1 User Feedback on IAC Services...22 6.0 FINANCIAL SUMMARY FY Operating expenditures for carrying out the Reliability Analysis Center’s on-going operational functions and satisfying...Because the RAC does n~ot stand to benefit from either a favorable or unfavorable appraisal of any contractors design, an unbiased analysis can result
Annual technical report, fiscal year 1979. Volume 1: Executive summary
NASA Technical Reports Server (NTRS)
Lucas, J. W.
1980-01-01
Accomplishments of the Point-Focusing Distributed Receiver Technology project are presented. The following aspects of the project are discussed: information dissemination, concentrator development, receiver and heat transport network development, power conversion, manufacturing, systems engineering, and tests and evaluations.
14 CFR 91.1417 - CAMP: Mechanical interruption summary report.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 2 2010-01-01 2010-01-01 false CAMP: Mechanical interruption summary... Ownership Operations Program Management § 91.1417 CAMP: Mechanical interruption summary report. Each program... route, caused by known or suspected mechanical difficulties or malfunctions that are not required to be...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1993-06-01
The report was prepared by The M. W. Kellogg Co. for BOTAS Petroleum Pipeline Corporation of Ankara, Turkey. The study was undertaken to evaluate the cost and economics of constructing a second liquified natural gas (LNG) terminal in Turkey to meet future requirements for natural gas. Volume 1 is divided into the following sections: (1) Introduction; (2) Summary and Conclusions; (3) Design Basis; (4) Site Evaluation; (5) LNG Terminal Design; (6) Major Equipment and Instrumentation; (7) Marine Operations; (8) Safety Considerations; (9) Environmental Review; (10) Preliminary Project Execution Strategy; (11) Cost Estimates; (12) Project Master Schedule; (13) Economic Analysis; (14)more » Financing; (15) Future Work.« less
Abbas, S M; Bissett, I P; Parry, B R
2007-04-01
Adhesions are the leading cause of small bowel obstruction. Identification of patients who require surgery is difficult. This review analyses the role of Gastrografin as a diagnostic and therapeutic agent in the management of adhesive small bowel obstruction. A systematic search of Medline, Embase and Cochrane databases was performed to identify studies of the use of Gastrografin in adhesive small bowel obstruction. Studies that addressed the diagnostic role of water-soluble contrast agent were appraised, and data presented as sensitivity, specificity, and positive and negative likelihood ratios. Results were pooled and a summary receiver-operator characteristic (ROC) curve was constructed. A meta-analysis of the data from six therapeutic studies was performed using the Mantel-Haenszel test and both fixed- and random-effect models. The appearance of water-soluble contrast agent in the colon on an abdominal radiograph within 24 h of its administration predicted resolution of obstruction with a pooled sensitivity of 97 per cent and specificity of 96 per cent. The area under the summary ROC curve was 0.98. Water-soluble contrast agent did not reduce the need for surgical intervention (odds ratio 0.81, P = 0.300), but it did reduce the length of hospital stay for patients who did not require surgery compared with placebo (weighted mean difference--1.84 days; P < 0.001). Published data strongly support the use of water-soluble contrast medium as a predictive test for non-operative resolution of adhesive small bowel obstruction. Although Gastrografin does not reduce the need for operation, it appears to shorten the hospital stay for those who do not require surgery.
NASA Technical Reports Server (NTRS)
1975-01-01
Summaries are presented of Research and Technology Operating Plans currently in progress throughout NASA. Citations and abstracts of the operating plans are presented along with a subject index, technical monitor index, and responsible NASA organization index. Research programs presented include those carried out in the Office of Aeronautics and Space Technology, Office of Energy Programs, Office of Applications, Office of Space Sciences, Office of Tracking and Data Acquisition, and the Office of Manned Space Flight.
ERIC Educational Resources Information Center
Minnesota State Dept. of Education, St. Paul. Div. of Vocational and Technical Education.
THIS MODULE OF A 30-MODULE COURSE IS DESIGNED TO PROVIDE A SUMMARY OF DIESEL ENGINE MAINTENANCE FACTORS AND A REVIEW OF DIESEL ENGINE ALTERNATOR OPERATION. THE SEVEN SECTIONS COVER DIESEL ENGINE TROUBLESHOOTING AND THE OPERATION, TESTING, AND ADJUSTING OF ALTERNATORS. THE MODULE CONSISTS OF A SELF-INSTRUCTIONAL BRANCH PROGRAMED TRAINING FILM…
Receiving a summary of the results of a trial: qualitative study of participants' views
Dixon-Woods, Mary; Jackson, Clare; Windridge, Kate C; Kenyon, Sara
2006-01-01
Objective To explore trial participants' responses to receiving a summary of the results of a trial in pregnancy. Design Qualitative study with semistructured interviews. Participants 20 women who had when pregnant participated in the ORACLE trial of antibiotics for preterm labour and preterm rupture of the membranes and requested a copy of the trial results. Results Less than a fifth of women who participated in the ORACLE trial indicated that they wished to receive the trial results. Reactions to the leaflet summarising the trial results were generally positive or neutral, although some women had difficulty in understanding the leaflet, and there was evidence of possible negative implications for women who had adverse outcomes. Women requested the results because they were interested in being able to complete their own personal narrative. They wished to know to which arm of the trial they had been allocated and the implications for their own pregnancy, and they were disappointed with receiving a generic summary. Women's accounts indicated some confusion about the trial findings. Conclusions Recommendations that research participants be routinely provided with the results of studies have been made without the benefit of research to show the consequences of doing this or how it should best be managed. Caution is needed, as is more evaluation of how feedback of results should be handled, and assessment of the risks, benefits, and costs. PMID:16401631
Yin, J Y; Ho, K M
2012-07-01
This systematic review and meta-analysis assessed the accuracy of plethysmographic variability index derived from the Massimo(®) pulse oximeter to predict preload responsiveness in peri-operative and critically ill patients. A total of 10 studies were retrieved from the literature, involving 328 patients who met the selection criteria. Overall, the diagnostic odds ratio (16.0; 95% CI 5-48) and area under the summary receiver operating characteristic curve (0.87; 95% CI 0.78-0.95) for plethysmographic variability index to predict fluid or preload responsiveness was very good, but significant heterogeneity existed. This could be explained by a lower accuracy of plethysmographic variability index in spontaneously breathing or paediatric patients and those studies that used pre-load challenges other than colloid fluid. The results indicate specific directions for future studies. Anaesthesia © 2012 The Association of Anaesthetists of Great Britain and Ireland.
DOT National Transportation Integrated Search
2010-09-01
The overall purpose of this research project as described in : the Executive Summary Report for Volume 1 : (FHWA/OH-2010/04A) is to identify flexible, rigid and : composite pavements that have not received any structural : maintenance since construct...
Broken Promises: How the Bush Administration is Failing America's Children [with] Executive Summary.
ERIC Educational Resources Information Center
Children's Defense Fund, Washington, DC.
Asserting that President Bush's proposal to shift responsibility for Head Start to the states would allow the federal government to abandon its promise to truly give children a head start, this report, with accompanying executive summary, outlines what is known about children receiving Head Start services and how the program addresses their needs.…
A Summary of Evaluations for Learning and Attention Problems at a University Training Clinic
ERIC Educational Resources Information Center
Wierzbicki, Michael; Tyson, Clare M.
2007-01-01
Over a five year period, a university clinic performed psychological evaluations of 102 adults (including 85 college students) who reported that they were experiencing learning or attention problems. Of 92 persons who completed the evaluation, 40 (43.5%) received no diagnosis, 7 (7.6%) received the diagnosis of ADHD, 29 (31.5%) received the…
76 FR 2441 - Proposed Agency Information Collection Activities; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2011-01-13
... mandated by Federal regulations. In summary, FRA reasons that comments received will advance three... assigned OMB control number in any correspondence submitted. FRA will summarize comments received in... activities are necessary for FRA to properly execute its functions, including whether the activities will...
Revised Report: A Summary of ETV Station Information.
ERIC Educational Resources Information Center
National Association of Educational Broadcasters, Washington, DC.
A summary of 186 educational television stations in the United States is presented. Stations are listed in order of State by call letters, and information concerning height of antenna (as related to commercial stations), color facilities, and operation below or at authorized power is included for each station. A summary of this information is…
Diagnosis of adrenal insufficiency.
Dorin, Richard I; Qualls, Clifford R; Crapo, Lawrence M
2003-08-05
The cosyntropin stimulation test is the initial endocrine evaluation of suspected primary or secondary adrenal insufficiency. To critically review the utility of the cosyntropin stimulation test for evaluating adrenal insufficiency. The MEDLINE database was searched from 1966 to 2002 for all English-language papers related to the diagnosis of adrenal insufficiency. Studies with fewer than 5 persons with primary or secondary adrenal insufficiency or with fewer than 10 persons as normal controls were excluded. For secondary adrenal insufficiency, only studies that stratified participants by integrated tests of adrenal function were included. Summary receiver-operating characteristic (ROC) curves were generated from all studies that provided sensitivity and specificity data for 250-microg and 1-microg cosyntropin tests; these curves were then compared by using area under the curve (AUC) methods. All estimated values are given with 95% CIs. At a specificity of 95%, sensitivities were 97%, 57%, and 61% for summary ROC curves in tests for primary adrenal insufficiency (250-microg cosyntropin test), secondary adrenal insufficiency (250-microg cosyntropin test), and secondary adrenal insufficiency (1-microg cosyntropin test), respectively. The area under the curve for primary adrenal insufficiency was significantly greater than the AUC for secondary adrenal insufficiency for the high-dose cosyntropin test (P < 0.001), but AUCs for the 250-microg and 1-microg cosyntropin tests did not differ significantly (P > 0.5) for secondary adrenal insufficiency. At a specificity of 95%, summary ROC analysis for the 250-microg cosyntropin test yielded a positive likelihood ratio of 11.5 (95% CI, 8.7 to 14.2) and a negative likelihood ratio of 0.45 (CI, 0.30 to 0.60) for the diagnosis of secondary adrenal insufficiency. Cortisol response to cosyntropin varies considerably among healthy persons. The cosyntropin test performs well in patients with primary adrenal insufficiency, but the lower sensitivity in patients with secondary adrenal insufficiency necessitates use of tests involving stimulation of the hypothalamus if the pretest probability is sufficiently high. The operating characteristics of the 250-microg and 1-microg cosyntropin tests are similar.
Tests for predicting complications of pre-eclampsia: A protocol for systematic reviews
Thangaratinam, Shakila; Coomarasamy, Arri; Sharp, Steve; O'Mahony, Fidelma; O'Brien, Shaughn; Ismail, Khaled MK; Khan, Khalid S
2008-01-01
Background Pre-eclampsia is associated with several complications. Early prediction of complications and timely management is needed for clinical care of these patients to avert fetal and maternal mortality and morbidity. There is a need to identify best testing strategies in pre eclampsia to identify the women at increased risk of complications. We aim to determine the accuracy of various tests to predict complications of pre-eclampsia by systematic quantitative reviews. Method We performed extensive search in MEDLINE (1951–2004), EMBASE (1974–2004) and also will also include manual searches of bibliographies of primary and review articles. An initial search has revealed 19500 citations. Two reviewers will independently select studies and extract data on study characteristics, quality and accuracy. Accuracy data will be used to construct 2 × 2 tables. Data synthesis will involve assessment for heterogeneity and appropriately pooling of results to produce summary Receiver Operating Characteristics (ROC) curve and summary likelihood ratios. Discussion This review will generate predictive information and integrate that with therapeutic effectiveness to determine the absolute benefit and harm of available therapy in reducing complications in women with pre-eclampsia. PMID:18694494
EVALUATING RISK-PREDICTION MODELS USING DATA FROM ELECTRONIC HEALTH RECORDS.
Wang, L E; Shaw, Pamela A; Mathelier, Hansie M; Kimmel, Stephen E; French, Benjamin
2016-03-01
The availability of data from electronic health records facilitates the development and evaluation of risk-prediction models, but estimation of prediction accuracy could be limited by outcome misclassification, which can arise if events are not captured. We evaluate the robustness of prediction accuracy summaries, obtained from receiver operating characteristic curves and risk-reclassification methods, if events are not captured (i.e., "false negatives"). We derive estimators for sensitivity and specificity if misclassification is independent of marker values. In simulation studies, we quantify the potential for bias in prediction accuracy summaries if misclassification depends on marker values. We compare the accuracy of alternative prognostic models for 30-day all-cause hospital readmission among 4548 patients discharged from the University of Pennsylvania Health System with a primary diagnosis of heart failure. Simulation studies indicate that if misclassification depends on marker values, then the estimated accuracy improvement is also biased, but the direction of the bias depends on the direction of the association between markers and the probability of misclassification. In our application, 29% of the 1143 readmitted patients were readmitted to a hospital elsewhere in Pennsylvania, which reduced prediction accuracy. Outcome misclassification can result in erroneous conclusions regarding the accuracy of risk-prediction models.
Allocation of Resources to Communication of Research Result Summaries.
Richards, Julie E; Bane, Emmi; Fullerton, Stephanie M; Ludman, Evette J; Jarvik, Gail
2016-10-01
Researchers and policymakers recommend communicating summary research results to biobank participants when feasible. To date, however, there have been few explorations of participant preferences for dedicating resources to this activity. Fifteen semi-structured interviews were conducted with participants of a genetic medicine biobank. Participants were interviewed by phone about their motivation for participation, and opinions about the allocation of resources to communicating summary results. De-identified transcripts were used for a directed content analysis. Most biobank participation was altruistic. All participants were not only interested in receiving summary results but also expressed a clear preference for allocating limited funds to conducting additional genetic research. The results suggest that participants have a nuanced view about the allocation of biobank resources to returning summary results, and asking their opinion is a valuable exercise. Researchers may benefit from transparency about research goals and involving biobank participants in decisions about return of summary results.
Park, Ki Byung; Shin, Joon-Shik; Lee, Jinho; Lee, Yoon Jae; Kim, Me-Riong; Lee, Jun-Hwan; Shin, Kyung-Min; Shin, Byung-Cheul; Cho, Jae-Heung; Ha, In-Hyuk
2017-04-15
.: Prospective observational 1-year study. .: To determine minimum clinically important difference (MCID) and substantial clinical benefit (SCB) of outcome measures in failed back surgery syndrome (FBSS) patients, as these metrics enable assessment of whether and when an intervention produces clinically meaningful effects in a patient. .: Several methods have been devised to quantify clinically important difference, but MCID and SCB for FBSS patients has yet to be determined. .: Patients with persisting/recurrent low back pain (LBP) and/or leg pain after lumbar surgery who completed 16 weeks of treatment (n = 105) at two hospitals in Korea from November 2011 to September 2014 were analyzed. Global perceived effect was used to determine receiver operating characteristic curves in visual analogue scale (VAS), Oswestry disability index (ODI), and short form-36 (SF-36) in an anchor-based approach. .: MCIDs for ODI, LBP and leg pain VAS, physical component summary, mental health component summary (MCS), and overall health scores of SF-36 were 9.0, 22.5, 27.5, 10.2, 4.0, and 8.9, and SCBs were 15.0, 32.5, 37.0, 19.7, 19.3, and 21.1, respectively. MCID and SCB area under the curve was ≥0.8, and ≥0.7, respectively. .: LBP and leg pain VAS, ODI, and physical component summary of SF-36 may be used to measure responsiveness in FBSS patients. 3.
Kim, Jeong Rye; Suh, Chong Hyun; Yoon, Hee Mang; Lee, Jin Seong; Cho, Young Ah; Jung, Ah Young
2018-03-01
To assess the diagnostic performance of shear-wave elastography for determining the severity of liver fibrosis in children and adolescents. An electronic literature search of PubMed and EMBASE was conducted. Bivariate modelling and hierarchical summary receiver-operating-characteristic modelling were performed to evaluate the diagnostic performance of shear-wave elastography. Meta-regression and subgroup analyses according to the modality of shear-wave imaging and the degree of liver fibrosis were also performed. Twelve eligible studies with 550 patients were included. Shear-wave elastography showed a summary sensitivity of 81 % (95 % CI: 71-88) and a specificity of 91 % (95 % CI: 83-96) for the prediction of significant liver fibrosis. The number of measurements of shear-wave elastography performed was a significant factor influencing study heterogeneity. Subgroup analysis revealed shear-wave elastography to have an excellent diagnostic performance according to each degree of liver fibrosis. Supersonic shear imaging (SSI) had a higher sensitivity (p<.01) and specificity (p<.01) than acoustic radiation force impulse imaging (ARFI). Shear-wave elastography is an excellent modality for the evaluation of the severity of liver fibrosis in children and adolescents. Compared with ARFI, SSI showed better diagnostic performance for prediction of significant liver fibrosis. • Shear-wave elastography is beneficial for determining liver fibrosis severity in children. • Shear-wave elastography showed summary sensitivity of 81 %, specificity of 91 %. • SSI showed better diagnostic performance than ARFI for significant liver fibrosis.
Meta-analysis of diagnostic accuracy studies in mental health
Takwoingi, Yemisi; Riley, Richard D; Deeks, Jonathan J
2015-01-01
Objectives To explain methods for data synthesis of evidence from diagnostic test accuracy (DTA) studies, and to illustrate different types of analyses that may be performed in a DTA systematic review. Methods We described properties of meta-analytic methods for quantitative synthesis of evidence. We used a DTA review comparing the accuracy of three screening questionnaires for bipolar disorder to illustrate application of the methods for each type of analysis. Results The discriminatory ability of a test is commonly expressed in terms of sensitivity (proportion of those with the condition who test positive) and specificity (proportion of those without the condition who test negative). There is a trade-off between sensitivity and specificity, as an increasing threshold for defining test positivity will decrease sensitivity and increase specificity. Methods recommended for meta-analysis of DTA studies --such as the bivariate or hierarchical summary receiver operating characteristic (HSROC) model --jointly summarise sensitivity and specificity while taking into account this threshold effect, as well as allowing for between study differences in test performance beyond what would be expected by chance. The bivariate model focuses on estimation of a summary sensitivity and specificity at a common threshold while the HSROC model focuses on the estimation of a summary curve from studies that have used different thresholds. Conclusions Meta-analyses of diagnostic accuracy studies can provide answers to important clinical questions. We hope this article will provide clinicians with sufficient understanding of the terminology and methods to aid interpretation of systematic reviews and facilitate better patient care. PMID:26446042
Race to the Top. Florida Report. Year 1: School Year 2010-2011. [State-Specific Summary Report
ERIC Educational Resources Information Center
US Department of Education, 2012
2012-01-01
This State-specific summary report serves as an assessment of Florida's Year 1 Race to the Top implementation, highlighting successes and accomplishments, identifying challenges, and providing lessons learned from implementation to date. Florida received a Race to the Top award in September 2010 as part of Phase 2 of the Race to the Top…
Parashos, Sotirios A; Luo, Sheng; Biglan, Kevin M; Bodis-Wollner, Ivan; He, Bo; Liang, Grace S; Ross, G Webster; Tilley, Barbara C; Shulman, Lisa M
2014-06-01
Optimizing assessments of rate of progression in Parkinson disease (PD) is important in designing clinical trials, especially of potential disease-modifying agents. To examine the value of measures of impairment, disability, and quality of life in assessing progression in early PD. Inception cohort analysis of data from 413 patients with early, untreated PD who were enrolled in 2 multicenter, randomized, double-blind clinical trials. Participants were randomly assigned to 1 of 5 treatments (67 received creatine, 66 received minocycline, 71 received coenzyme Q10, 71 received GPI-1485, and 138 received placebo). We assessed the association between the rates of change in measures of impairment, disability, and quality of life and time to initiation of symptomatic treatment. Time between baseline assessment and need for the initiation of symptomatic pharmaceutical treatment for PD was the primary indicator of disease progression. After adjusting for baseline confounding variables with regard to the Unified Parkinson's Disease Rating Scale (UPDRS) Part II score, the UPDRS Part III score, the modified Rankin Scale score, level of education, and treatment group, we assessed the rate of change for the following measurements: the UPDRS Part II score; the UPDRS Part III score; the Schwab and England Independence Scale score (which measures activities of daily living); the Total Functional Capacity scale; the 39-item Parkinson's Disease Questionnaire, summary index, and activities of daily living subscale; and version 2 of the 12-item Short Form Health Survey Physical Summary and Mental Summary. Variables reaching the statistical threshold in univariate analysis were entered into a multivariable Cox proportional hazards model using time to symptomatic treatment as the dependent variable. More rapid change (ie, worsening) in the UPDRS Part II score (hazard ratio, 1.15 [95% CI, 1.08-1.22] for 1 scale unit change per 6 months), the UPDRS Part III score (hazard ratio, 1.09 [95% CI, 1.06-1.13] for 1 scale unit change per 6 months), and the Schwab and England Independence Scale score (hazard ratio, 1.29 [95% CI, 1.12-1.48] for 5 percentage point change per 6 months) was associated with earlier need for symptomatic therapy. AND RELEVANCE In early PD, the UPDRS Part II score and Part III score and the Schwab and England Independence Scale score can be used to measure disease progression, whereas the 39-item Parkinson's Disease Questionnaire and summary index, Total Functional Capacity scale, and the 12-item Short Form Health Survey Physical Summary and Mental Summary are not sensitive to change. clinicaltrials.gov Identifiers: NCT00063193 and NCT00076492.
NASA Astrophysics Data System (ADS)
Beaty, David W.; Allen, Carlton C.; Bass, Deborah S.; Buxbaum, Karen L.; Campbell, James K.; Lindstrom, David J.; Miller, Sylvia L.; Papanastassiou, Dimitri A.
2009-10-01
It has been widely understood for many years that an essential component of a Mars Sample Return mission is a Sample Receiving Facility (SRF). The purpose of such a facility would be to take delivery of the flight hardware that lands on Earth, open the spacecraft and extract the sample container and samples, and conduct an agreed-upon test protocol, while ensuring strict containment and contamination control of the samples while in the SRF. Any samples that are found to be non-hazardous (or are rendered non-hazardous by sterilization) would then be transferred to long-term curation. Although the general concept of an SRF is relatively straightforward, there has been considerable discussion about implementation planning. The Mars Exploration Program carried out an analysis of the attributes of an SRF to establish its scope, including minimum size and functionality, budgetary requirements (capital cost, operating costs, cost profile), and development schedule. The approach was to arrange for three independent design studies, each led by an architectural design firm, and compare the results. While there were many design elements in common identified by each study team, there were significant differences in the way human operators were to interact with the systems. In aggregate, the design studies provided insight into the attributes of a future SRF and the complex factors to consider for future programmatic planning.
Beaty, David W; Allen, Carlton C; Bass, Deborah S; Buxbaum, Karen L; Campbell, James K; Lindstrom, David J; Miller, Sylvia L; Papanastassiou, Dimitri A
2009-10-01
It has been widely understood for many years that an essential component of a Mars Sample Return mission is a Sample Receiving Facility (SRF). The purpose of such a facility would be to take delivery of the flight hardware that lands on Earth, open the spacecraft and extract the sample container and samples, and conduct an agreed-upon test protocol, while ensuring strict containment and contamination control of the samples while in the SRF. Any samples that are found to be non-hazardous (or are rendered non-hazardous by sterilization) would then be transferred to long-term curation. Although the general concept of an SRF is relatively straightforward, there has been considerable discussion about implementation planning. The Mars Exploration Program carried out an analysis of the attributes of an SRF to establish its scope, including minimum size and functionality, budgetary requirements (capital cost, operating costs, cost profile), and development schedule. The approach was to arrange for three independent design studies, each led by an architectural design firm, and compare the results. While there were many design elements in common identified by each study team, there were significant differences in the way human operators were to interact with the systems. In aggregate, the design studies provided insight into the attributes of a future SRF and the complex factors to consider for future programmatic planning.
Research and technology operating plan: A summary Fiscal Year 1974. [bibliography
NASA Technical Reports Server (NTRS)
1973-01-01
A compilation is presented of the summary portions of RTOPs used for management review and control of research. Citations and abstracts of RTOPs are included. A list is presented of RTOPs which have been changed, completed, or terminated since the last summary. Indexes presented include: subject, technical monitor, responsible NASA organization, and RTOP number.
75 FR 70965 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2010-11-19
... Federal holidays. Privacy: We will post all comments we receive, without change, to http:[sol][sol]www...., Monday through Friday, except Federal holidays. FOR FURTHER INFORMATION CONTACT: Keira Jones, 202-267... Exemption Docket No.: FAA-2010-0947 and FAA-2010-0970. Petitioner: Seaborne Virgin Islands, Inc. d.b.a...
78 FR 73919 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2013-12-09
... post all comments we receive, without change, to http://www.regulations.gov , including any personal... INFORMATION CONTACT: Mr. Brian Hancock, Flight Test Pilot, Project Support (ACE-112), Small Airplane....: FAA-2013-0795. Petitioner: Cirrus Design Corporation. Section of 14 CFR Affected: 14 CFR 23.177(b...
78 FR 28000 - Notice of Permit Applications Received Under the Antarctic Conservation Act of 1978
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-13
... Conservation Act of 1978 AGENCY: National Science Foundation. ACTION: Notice of Permit Applications Received under the Antarctic Conservation Act of 1978, Public Law 95-541. SUMMARY: The National Science... regulated under the Antarctic Conservation Act of 1978. NSF has published regulations under the Antarctic...
77 FR 67407 - Notice of Permit Applications Received Under the Antarctic Conservation Act of 1978
Federal Register 2010, 2011, 2012, 2013, 2014
2012-11-09
... Conservation Act of 1978 AGENCY: National Science Foundation. ACTION: Notice of Permit Applications Received under the Antarctic Conservation Act of 1978, Public Law 95-541. SUMMARY: The National Science... regulated under the Antarctic Conservation Act of 1978. NSF has published regulations under the Antarctic...
77 FR 38834 - Notice of Permit Applications Received Under the Antarctic Conservation Act of 1978
Federal Register 2010, 2011, 2012, 2013, 2014
2012-06-29
... Conservation Act of 1978 AGENCY: National Science Foundation. ACTION: Notice of permit applications received under the Antarctic Conservation Act of 1978. SUMMARY: The National Science Foundation (NSF) is required... Antarctic Conservation Act of 1978. NSF has published regulations under the Antarctic Conservation Act. This...
75 FR 27556 - Agency Information Collection Activities: Final Collection; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2010-05-17
... utilization and management prospective insurance liability relative to risk premiums received. DATES: Comments... utilization and management prospective insurance liability relative to risk premiums received. Affected Public... 92-30). SUMMARY: The Export-Import Bank of the United States (Ex-Im Bank), as a part of its...
Frank, Oliver; Aylward, Paul; Stocks, Nigel
2014-05-01
Patients attending general practices receive about 60% of indicated preventive services. Patients do not know which preventive services are indicated for them and want their GPs to offer those services. Patients arriving for consultations in three general practices received individualised prevention summary sheets. Acceptability was assessed by patient survey. Sustainability was assessed by the number of sheets printed over time. Seventy-two percent of patients discussed the advice on their sheet in the consultation, and 89% wanted to receive the sheets in the future. Practices printed 8882 sheets in the 52 weeks from the start of the trial. This new intervention seems to be acceptable and sustainable in the Australian setting. It has the potential, therefore, to increase the delivery of preventive care in general practice. A larger trial is needed to demonstrate its effect on performance of preventive activities and on patient outcomes.
Research and Technology Operating Plan. Summary: Fiscal year 1976 research and technology program
NASA Technical Reports Server (NTRS)
1976-01-01
A compilation of the summary portions of each of the Research and Technology Operating Plans (RTOP) used for management review and control of research currently in progress throughout NASA was presented. The document is arranged in five sections. The first one contains citations and abstracts of the RTOP. This is followed by four indexes: subject, technical monitor, responsible NASA organization, and RTOP number.
Schneider, Yvonne; Beier, Maike; Rosenwinkel, Karl‐Heinz
2012-01-01
Summary Due to its high global warming potential, nitrous oxide (N2O) emissions from wastewater treatment processes have recently received a high degree of attention. Nevertheless, there is still a lack of information regarding the microbiological processes leading to N2O production. In this study, two lab‐scale sequencing batch reactors were operated with deammonification biomass to investigate the role of denitrification and the influence of substrate availability regarding N2O formation during the anoxic phase of deammonification. Three different operational phases were established: within the first phase conversion by anammox was favoured and after a transition phase, denitrification activity was promoted. Low nitrous oxide production was observed during stable operation aiming for anammox conversion. Pulsed inflow of the wastewater containing ammonium (NH4+) and nitrite (NO2‐) led to increased N2O production rates. Within the period of denitrification as dominating nitrogen conversion process, the nitrous oxide concentration level was higher during continuous inflow conditions, but the reaction to pulsed inflow was less pronounced. The results indicated that denitrification was responsible for N2O formation from the deammonification biomass. Operational settings to achieve suppression of denitrification processes to a large extend were deducted from the results of the experiments. PMID:22296600
NASA Technical Reports Server (NTRS)
1980-01-01
Candidate satellite power system (SPS) concepts were identified and evaluated in terms of technical and cost factors. A number of alternative technically feasible approaches and system concepts were investigated. A reference system was defined to facilitate economic, environmental, and societal assessments by the Department of Energy. All elements of the reference system were defined including the satellite and all its subsystems, the orbital construction and maintenance bases, all elements of the space transportation system, the ground receiving station, and the associated industrial facilities for manufacturing the required hardware. The reference conclusions and remaining issues are stated for the following topical areas: system definition; energy conversion and power management; power transmission and reception; structures, controls, and materials; construction and operations; and space transportation.
Omega flight-test data reduction sequence. [computer programs for reduction of navigation data
NASA Technical Reports Server (NTRS)
Lilley, R. W.
1974-01-01
Computer programs for Omega data conversion, summary, and preparation for distribution are presented. Program logic and sample data formats are included, along with operational instructions for each program. Flight data (or data collected in flight format in the laboratory) is provided by the Ohio University Omega receiver base in the form of 6-bit binary words representing the phase of an Omega station with respect to the receiver's local clock. All eight Omega stations are measured in each 10-second Omega time frame. In addition, an event-marker bit and a time-slot D synchronizing bit are recorded. Program FDCON is used to remove data from the flight recorder tape and place it on data-processing cards for later use. Program FDSUM provides for computer plotting of selected LOP's, for single-station phase plots, and for printout of basic signal statistics for each Omega channel. Mean phase and standard deviation are printed, along with data from which a phase distribution can be plotted for each Omega station. Program DACOP simply copies the Omega data deck a controlled number of times, for distribution to users.
Radiological Operations Support Specialist (ROSS) Pilot Course Summary and Recommendations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Alai, M.; Askin, A.; Buddemeier, B.
In support of the Department of Homeland Security / Science and Technology Directorate’s (DHS/S&T) creation of a new position called the Radiological Operations Support Specialist (ROSS), Lawrence Livermore National Laboratory (LLNL) in Sub-task 1.1 and 1.2 has assisted in the development of the ROSS skills, knowledge, and abilities (SKAs); identified potentially relevant training; cross-mapped the training to the SKAs; and identified gaps in the training related to the SKAs, as well as their respective level of training knowledge - current versus desired. In the follow on task, Sub-task 1.3, a 5 day ROSS Pilot Training course was developed to fillmore » the priority gaps identified in Sub-Task 1.2. Additionally, in Sub-Task 1.5, LLNL has performed a gap analysis of electronic tools, handbooks, and job-aides currently available to the ROSS and developed recommendations for additional and next generation tools to ensure the operational effectiveness of the ROSS position. This document summarizes the feedback received from the instructors and pilot course observers on what worked in the course and what could be improved as well as an assessment of the Pre- and Post-Test administered to the students.« less
NASA Technical Reports Server (NTRS)
Garrocq, C. A.; Hurley, M. J.
1973-01-01
An overview is provided of the Ipad System, including its goals and objectives, organization, capabilities and future usefulness. The systems implementation is also presented with operational cost summaries.
Tiwari, Tejpratap; Moro, Pedro; Messonnier, Nancy E.; Reingold, Arthur; Sawyer, Mark; Clark, Thomas A.
2018-01-01
Summary This report compiles and summarizes all recommendations from CDC's Advisory Committee on Immunization Practices (ACIP) regarding prevention and control of tetanus, diphtheria, and pertussis in the United States. As a comprehensive summary of previously published recommendations, this report does not contain any new recommendations and replaces all previously published reports and policy notes; it is intended for use by clinicians and public health providers as a resource. ACIP recommends routine vaccination for tetanus, diphtheria, and pertussis. Infants and young children are recommended to receive a 5-dose series of diphtheria and tetanus toxoids and acellular pertussis (DTaP) vaccines, with one adolescent booster dose of tetanus toxoid, reduced diphtheria toxoid, and acellular pertussis (Tdap) vaccine. Adults who have never received Tdap also are recommended to receive a booster dose of Tdap. Women are recommended to receive a dose of Tdap during each pregnancy, which should be administered from 27 through 36 weeks’ gestation, regardless of previous receipt of Tdap. After receipt of Tdap, adolescents and adults are recommended to receive a booster tetanus and diphtheria toxoids (Td) vaccine every 10 years to assure ongoing protection against tetanus and diphtheria. PMID:29702631
Stanford Synchrotron Radiation Laboratory. Activity report for 1989
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1996-01-01
The April, 1990 SPEAR synchrotron radiation run was one of the two or three best in SSRL`s history. High currents were accumulated, ramping went easily, lifetimes were long, beam dumps were infrequent and the average current was 42.9 milliamps. In the one month of operation, 63 different experiments involving 208 scientists from 50 institutions received beam. The end-of-run summary forms completed by the experimenters indicated high levels of user satisfaction with the beam quality and with the outstanding support received from the SSRL technical and scientific staffs. These fine experimental conditions result largely from the SPEAR repairs and improvements performedmore » during the past year and described in Section I. Also quite significant was Max Cornacchia`s leadership of the SLAG staff. SPEAR`s performance this past April stands in marked contrast to that of the January-March, 1989 run which is also described in Section I. It is, we hope, a harbinger of the operation which will be provided in FY `91, when the SPEAR injector project is completed and SPEAR is fully dedicated to synchrotron radiation research. Over the coming years, SSRL intends to give highest priority to increasing the effectiveness of SPEAR and its various beam lines. The beam line and facility improvements performed during 1989 are described in Section III. In order to concentrate effort on SSRL`s three highest priorities prior to the March-April run: (1) to have a successful run, (2) to complete and commission the injector, and (3) to prepare to operate, maintain and improve the SPEAR/injector system, SSRL was reorganized. In the new organization, all the technical staff is contained in three groups: Accelerator Research and Operations Division, Injector Project and Photon Research and Operations Division, as described in Section IV. In spite of the limited effectiveness of the January-March, 1989 run, SSRL`s users made significant scientific progress, as described in Section V of this report.« less
Space station operations task force summary report
NASA Technical Reports Server (NTRS)
1987-01-01
A companion to the Space Stations Operation Task Force Panels' Reports, this document summarizes all space station program goals, operations, and the characteristics of the expected user community. Strategies for operation and recommendations for implementation are included.
Hanford Atomic Products Operation monthly report, March 1954
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1954-04-23
This document presents a summary of work and progress at the Hanford Engineer Works for March 1954. The report is divided into sections by department. A plant wide general summary is included at the beginning of the report, after which the departmental summaries begin. The Manufacturing Department reports plant statistics, and summaries for the Metal Preparation, Reactor and Separation sections. The Engineering Department`s section summaries work for the Technical, Design, and Project Sections. Costs for the various departments are presented in the Financial Department`s summary. The Medical, Radiological Sciences, Utilities and General Services, Employee and Public Relations, and Community Realmore » Estate and Service departments have sections presenting their monthly statistics, work, progress, and summaries.« less
Hanford Atomic Products Operation monthly report, June 1954
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1954-07-26
This document presents a summary of work and progress at the Hanford Engineer Works for June 1954. The report is divided into sections by department. A plant wide general summary is included at the beginning of the report, after which the departmental summaries begin. The Manufacturing Department reports plant statistics, and summaries for the Metal Preparation, Reactor and Separation sections. The Engineering Department`s section summaries work for the Technical, Design, and Project Sections. Costs for the various departments are presented in the Financial Department`s summary. The Medical, Radiological Sciences, Utilities and General Services, Employee and Public Relations, and Community Realmore » Estate and Services departments have sections presenting their monthly statistics, work, progress, and summaries.« less
Hanford Atomic Products Operation monthly report, May 1954
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1954-06-22
This document presents a summary of work and progress at the Hanford Engineer Works for May 1954. The report is divided into sections by department. A plant wide general summary is included at the beginning of the report, after which the departmental summaries begin. The Manufacturing Department reports plant statistics, and summaries for the Metal Preparation, Reactor and Separation sections. The Engineering Department`s section summaries work for the Technical, Design, and Project Sections. Costs for the various departments are presented in the Financial Department`s summary. The Medical, Radiological Science, Utilities and General Services, Employee and Public Relations, and Community Realmore » Estate and Services departments have sections presenting their monthly statistics, work, progress, and summaries.« less
Hanford Atomic Products Operation monthly report, October 1953
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1953-11-20
This document presents a summary of work and progress at the Hanford Engineer Works for October 1953. The report is divided into sections by department. A plant wide general summary is included at the beginning of the report, after which the departmental summaries begin. The Manufacturing Department reports plant statistics, and summaries for the Metal Preparation, Reactor and Separation sections. The Engineering Department`s section summaries work for the Technical, Design, and Project Sections. Costs for the various departments are presented in the Financial Department`s summary. The Medical, Radiological Sciences, Utilities and General Services. Employee and Public Relations, and Community Realmore » Estate and Service departments have sections presenting their monthly statistics, work, progress, and summaries.« less
Hanford Atomic Products Operation monthly report, May 1953
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
This document presents a summary of work and progress at the Hanford Engineer Works for May 1953. The report is divided into sections by department. A plant wide general summary is included at the beginning of the report, after which the departmental summaries begin. The Manufacturing Department reports plant statistics, and summaries for the Metal Preparation, Reactor and Separation sections. The Engineering Department`s section summaries work for the Technical, Design, and Project Sections. Costs for the various departments are presented in the Financial Department`s summary. The Medical, Radiological Sciences, Utilities and General Services, Employee and Public Relations, and Community Realmore » Estate and Services departments have sections presenting their monthly statistics, work, progress, and summaries.« less
Hanford Atomic Products Operation monthly report, July 1953
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1953-08-20
This document presents a summary of work and progress at the Hanford Engineer Works for July 1953. The report is divided into sections by department. A plant wide general summary is included at the beginning of the report, after which the departmental summaries begin. The Manufacturing Department reports plant statistics, and summaries for the Metal Preparation, Reactor and Separation sections. The Engineering Department`s section summaries work for the Technical, Design, and Project Sections. Costs for the various departments are presented in the Financial Department`s summary. The Medical, Radiological Sciences, Utilities and General Services, Employee and Public Relations, and Community Realmore » Estate and Services departments have sections presenting their monthly statistics, work, progress, and summaries.« less
Hanford Atomic Products Operation monthly report for September 1954
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1954-10-25
This document presents a summary of work and progress at the Hanford Engineer Works for September 1954. The report is divided into sections by department. A plant wide general summary is included at the beginning of the report, after which the departmental summaries begin. The Manufacturing Department reports plant statistics, and summaries for the Metal Preparation, Reactor and Separation sections. The Engineering Department`s section summaries work for the Technical, Design, and Project Sections. Costs for the various departments are presented in the Financial Department`s summary. The Medical, Radiological Sciences, Utilities and General Services, Employee and Public Relations, and Community Realmore » Estate and Services departments have sections presenting their monthly statistics, work, progress, and summaries.« less
Hanford Atomic Products Operation monthly report, June 1953
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1953-07-22
This document presents a summary of work and progress at the Hanford Engineer Works for June 1953. The report is divided into sections by department. A plant wide general summary is included at the beginning of the report, after which the departmental summaries begin. The Manufacturing Department reports plant statistics, and summaries for the Metal Preparation, Reactor and Separation sections. The Engineering Department`s section summaries work the Technical, Design, and Project Sections. Costs for the various departments are presented in the Financial Department`s summary. The Medical, Radiological Sciences, Utilities and General Services, Employee and Public Relations, and Community Real Estatemore » and Services departments have sections presenting their monthly statistics, work, progress, and summaries.« less
Hanford Atomic Products Operation monthly report, December 1953
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1954-01-22
This document presents a summary of work and progress at the Hanford Engineer Works for December 1953. The report is divided into sections by department. A plant wide general summary is included at the beginning of the report, after which the departmental summaries begin. The Manufacturing Department reports plant statistics, and summaries for the Metal Preparation, Reactor and Separation sections. The Engineering Department`s section summaries work for the Technical, Design, and Project Sections. Costs for the various departments are presented in the Financial Department`s summary. The Medical, Radiological Sciences, Utilities and General Services, Employee and Public Relations, and Community Realmore » Estate and Services departments have sections presenting their monthly statistics, work, progress, and summaries.« less
Space tug economic analysis study. Volume 1: Executive summary
NASA Technical Reports Server (NTRS)
1972-01-01
An economic analysis of space tug operations is presented. The space tug is defined as any liquid propulsion stage under 100,000 pounds propellant loading that is flown from the space shuttle cargo bay. Two classes of vehicles are the orbit injection stages and reusable space tugs. The vehicle configurations, propellant combinations, and operating modes used for the study are reported. The summary contains data on the study approach, results, conclusions, and recommendations.
75 FR 10016 - Petition for Exemption; Summary of Petitions Received
Federal Register 2010, 2011, 2012, 2013, 2014
2010-03-04
..., except Federal holidays. Privacy: We will post all comments we receive, without change, to http://www... information and data that relate to the equipment, procedural practices, alternatives, and aeromedical factors.... Petitioner: FedEx Express. Section of 14 CFR Affected: Sec. 121.333(c)(3). Description of Relief Sought FedEx...
78 FR 23150 - Commercial Radio Operators
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-18
...] Commercial Radio Operators AGENCY: Federal Communications Commission. ACTION: Final rule. SUMMARY: This document amends our rules concerning commercial radio operator licenses for maritime and aviation radio... certain maritime and aviation radio stations hold an appropriate commercial radio operator license. The...
Can we improve the clinical utility of respiratory rate as a monitored vital sign?
Chen, Liangyou; Reisner, Andrew T; Gribok, Andrei; McKenna, Thomas M; Reifman, Jaques
2009-06-01
Respiratory rate (RR) is a basic vital sign, measured and monitored throughout a wide spectrum of health care settings, although RR is historically difficult to measure in a reliable fashion. We explore an automated method that computes RR only during intervals of clean, regular, and consistent respiration and investigate its diagnostic use in a retrospective analysis of prehospital trauma casualties. At least 5 s of basic vital signs, including heart rate, RR, and systolic, diastolic, and mean arterial blood pressures, were continuously collected from 326 spontaneously breathing trauma casualties during helicopter transport to a level I trauma center. "Reliable" RR data were identified retrospectively using automated algorithms. The diagnostic performances of reliable versus standard RR were evaluated by calculation of the receiver operating characteristic curves using the maximum-likelihood method and comparison of the summary areas under the receiver operating characteristic curves (AUCs). Respiratory rate shows significant data-reliability differences. For identifying prehospital casualties who subsequently receive a respiratory intervention (hospital intubation or tube thoracotomy), standard RR yields an AUC of 0.59 (95% confidence interval, 0.48-0.69), whereas reliable RR yields an AUC of 0.67 (0.57-0.77), P < 0.05. For identifying casualties subsequently diagnosed with a major hemorrhagic injury and requiring blood transfusion, standard RR yields an AUC of 0.60 (0.49-0.70), whereas reliable RR yields 0.77 (0.67-0.85), P < 0.001. Reliable RR, as determined by an automated algorithm, is a useful parameter for the diagnosis of respiratory pathology and major hemorrhage in a trauma population. It may be a useful input to a wide variety of clinical scores and automated decision-support algorithms.
Southeast Rail Operations (SEROps) : Phase I : Summary Report
DOT National Transportation Integrated Search
2008-05-01
This Summary Report documents the first phase of the SEROps study. Phase I investigated the regional rail transportation network in Florida, Georgia, North Carolina, and South Carolina as a system, and it engaged a diverse group of rail stakeholders ...
Financial statistics major US publicly owned electric utilities 1996
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1998-03-01
The 1996 edition of The Financial Statistics of Major US Publicly Owned Electric Utilities publication presents 5 years (1992 through 1996) of summary financial data and current year detailed financial data on the major publicly owned electric utilities. The objective of the publication is to provide Federal and State governments, industry, and the general public with current and historical data that can be used for policymaking and decision making purposes related to publicly owned electric utility issues. Generator and nongenerator summaries are presented in this publication. Five years of summary financial data are provided. Summaries of generators for fiscal yearsmore » ending June 30 and December 31, nongenerators for fiscal years ending June 30 and December 31, and summaries of all respondents are provided. The composite tables present aggregates of income statement and balance sheet data, as well as financial indicators. Composite tables also display electric operation and maintenance expenses, electric utility plant, number of consumers, sales of electricity, and operating revenue, and electric energy account data. 2 figs., 32 tabs.« less
75 FR 66709 - Commercial Radio Operators Rules
Federal Register 2010, 2011, 2012, 2013, 2014
2010-10-29
.... SUMMARY: This document proposes to amend our rules concerning commercial radio operator licenses for... operators service, to determine which rules can be clarified, streamlined, or eliminated. DATES: Submit... Radiotelegraph Operator's Certificates, and seek comment on extending the current five-year license for...
Utah Department of Transportation traffic operation center operator training.
DOT National Transportation Integrated Search
2010-11-01
This paper is a summary of work performed by the Utah Traffic Lab (UTL) to develop training programs for the Utah Department of Transportation (UDOT) Traffic Operations Center (TOC) operators at both the basic and advanced levels. The basic training ...
A Summary of the Naval Postgraduate School Research Program.
1983-05-01
environment . Of particular note here are the activities of the Environmental Physics Group, our work in electro-optics, and work anticipated in the...of natural light and the optical beam spread function of the ocean. The sponsor is DARPA. ENVIRONMENTAL ACOUSTICS G. H. Jung, R. H. Bourke, C. R... environmental phenomena determine the nature of ambient noise signals received at hydrophone arrays. Summary: During FY82, additional data bases were
1985-09-05
outlays were reduced to $2,419,100,000 because of a reduction of imports. Net capital flow increased to $161.4 million. [Summary] [Bogota EL SIGLO ...58.8 million more. [Summary] [Bogota EL SIGLO in Spanish 9 Aug 85 p 10 PA] AMBASSADOR TO SWITZERLAND—Foreign Minister Augusto Ocampo has sworn...opinion.was received by the trade unions, 27 percent; followed by Congress and private enterprise. B As for the possibility that religion
American War and Military Operations Casualties: Lists and Statistics
2015-01-02
Service 10 Table 7. Vietnam Conflict: Casualty Summary (as of December 22, 2014) Casualty Type Total Army Air Force Marines Navya Killed in Action...December 22, 2014) Casualty Type Total Army Air Force Marines Navya Killed in Action 144 96 20 22 6 Died of Wounds 4 2 0 2 0 Missing in Action—Declared...Service 17 Table 12. Operation Iraqi Freedom (OIF): Casualty Summary by Casualty Category (as of December 22, 2014) Casualty Type Total Army Navya
Statistical summary of commercial jet aircraft accidents : worldwide operations, 1959-2009
DOT National Transportation Integrated Search
2010-07-01
The accident statistics presented in this summary are confined to worldwide commercial jet airplanes that are heavier than 60,000 pounds maximum gross weight. Within that set of airplanes, there are two groups excluded: : 1) Airplanes manufactured in...
Chaikriangkrai, Kongkiat; Jhun, Hye Yeon; Shantha, Ghanshyam Palamaner Subash; Abdulhak, Aref Bin; Tandon, Rudhir; Alqasrawi, Musab; Klappa, Anthony; Pancholy, Samir; Deshmukh, Abhishek; Bhama, Jay; Sigurdsson, Gardar
2018-07-01
In aortic stenosis patients referred for surgical and transcatheter aortic valve replacement (AVR), the evidence of diagnostic accuracy of coronary computed tomography angiography (CCTA) has been limited. The objective of this study was to investigate the diagnostic accuracy of CCTA for significant coronary artery disease (CAD) in patients referred for AVR using invasive coronary angiography (ICA) as the gold standard. We searched databases for all diagnostic studies of CCTA in patients referred for AVR, which reported diagnostic testing characteristics on patient-based analysis required to pool summary sensitivity, specificity, positive-likelihood ratio, and negative-likelihood ratio. Significant CAD in both CCTA and ICA was defined by >50% stenosis in any coronary artery, coronary stent, or bypass graft. Thirteen studies evaluated 1498 patients (mean age, 74 y; 47% men; 76% transcatheter AVR). The pooled prevalence of significant stenosis determined by ICA was 43%. Hierarchical summary receiver-operating characteristic analysis demonstrated a summary area under curve of 0.96. The pooled sensitivity, specificity, and positive-likelihood and negative-likelihood ratios of CCTA in identifying significant stenosis determined by ICA were 95%, 79%, 4.48, and 0.06, respectively. In subgroup analysis, the diagnostic profiles of CCTA were comparable between surgical and transcatheter AVR. Despite the higher prevalence of significant CAD in patients with aortic stenosis than with other valvular heart diseases, our meta-analysis has shown that CCTA has a suitable diagnostic accuracy profile as a gatekeeper test for ICA. Our study illustrates a need for further study of the potential role of CCTA in preoperative planning for AVR.
78 FR 21245 - Continuity of Operations Plan
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-10
...; Order No. 778] Continuity of Operations Plan AGENCY: Federal Energy Regulatory Commission, DOE. ACTION: Final rule. SUMMARY: In this Final Rule the Commission revises its Continuity of Operations Plan... Commission's Continuity of Operations Plan (COOP) regulations to incorporate its regional offices into the...
DOT National Transportation Integrated Search
2003-03-17
The purpose of this effort is to independently evaluate the Battelle Operational Test Team to test methods for leveraging technology and operations to improve HAZMAT transport security, safety, and operational efficiency. As such, the preceding techn...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-03-28
... Collection Activities: Business Transformation--Automated Integrated Operating Environment (IOE), New... Transformation--Integrated Operating Environment (IOE); OMB Control No. 1615-NEW. SUMMARY: USCIS is developing an automated Integrated Operating Environment (IOE) to process benefit applications. The IOE will collect...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-05
... Conservation Act of 1978 (Pub. L. 95-541) AGENCY: National Science Foundation. ACTION: Notice of Permit Applications Received under the Antarctic Conservation Act of 1978, Public Law 95-541. SUMMARY: The National... activities regulated under the Antarctic Conservation Act of 1978. NSF has published regulations under the...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-09-19
... Conservation Act of 1978 (Pub. L. 95-541) AGENCY: National Science Foundation. ACTION: Notice of Permit Applications Received under the Antarctic Conservation Act of 1978, Public Law 95-541. SUMMARY: The National... activities regulated under the Antarctic Conservation Act of 1978. NSF has published regulations under the...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-10-13
... Conservation Act of 1978 (Pub .L. 95-541) AGENCY: National Science Foundation. ACTION: Notice of Permit Modification Received under the Antarctic Conservation Act of 1978, Public Law 95-541. SUMMARY: The National... activities regulated under the Antarctic Conservation Act of 1978. NSF has published regulations under the...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-08-22
... Conservation Act of 1978 (Pub. L. 95-541) AGENCY: National Science Foundation. ACTION: Notice of permit applications received under the Antarctic Conservation Act of 1978, Public Law 95-541. SUMMARY: The National... activities regulated under the Antarctic Conservation Act of 1978. NSF has published regulations under the...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-12
... Conservation Act of 1978 (Pub. L. 95-541) AGENCY: National Science Foundation. ACTION: Notice of Permit Modification Request Received under the Antarctic Conservation Act of 1978, Pub. L. 95-541. SUMMARY: The... conduct activities regulated under the Antarctic Conservation Act of 1978. NSF has published regulations...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-10-13
... Conservation Act of 1978 (Pub. L. 95-541) AGENCY: National Science Foundation. ACTION: Notice of Permit Applications Received under the Antarctic Conservation Act of 1978, Public Law 95-541. SUMMARY: The National... activities regulated under the Antarctic Conservation Act of 1978. NSF has published regulations under the...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-22
... Conservation Act of 1978 (Pub. L. 95-541) AGENCY: National Science Foundation. ACTION: Notice of Permit Applications Received under the Antarctic Conservation Act of 1978, Public Law 95-541. SUMMARY: The National... activities regulated under the Antarctic Conservation Act of 1978. NSF has published regulations under the...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-02-07
... Conservation Act of 1978 (Pub. L. 95-541) AGENCY: National Science Foundation. ACTION: Notice of Permit Applications Received Under the Antarctic Conservation Act of 1978, Public Law 95-541. SUMMARY: The National... activities regulated under the Antarctic Conservation Act of 1978. NSF has published regulations under the...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-09-07
... Conservation Act of 1978 (Pub. L. 95-541) AGENCY: National Science Foundation. ACTION: Notice of Permit Modification Received under the Antarctic Conservation Act of 1978, Public Law 95-541. SUMMARY: The National... activities regulated under the Antarctic Conservation Act of 1978. NSF has published regulations under the...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-05-07
... Conservation Act of 1978 (Pub. L. 95-541) AGENCY: National Science Foundation. ACTION: Notice of Permit Applications Received under the Antarctic Conservation Act of 1978, Public Law 95-541. SUMMARY: The National... activities regulated under the Antarctic Conservation Act of 1978. NSF has published regulations under the...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-25
... Conservation Act of 1978 (Pub. L. 95-541) AGENCY: National Science Foundation. ACTION: Notice of Permit Modification Received under the Antarctic Conservation Act of 1978, Public Law 95-541. SUMMARY: The National... activities regulated under the Antarctic Conservation Act of 1978. NSF has published regulations under the...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-24
... Conservation Act of 1978 (Pub. L. 95-541) AGENCY: National Science Foundation. ACTION: Notice of Permit Applications Received under the Antarctic Conservation Act of 1978, Public Law 95-541. SUMMARY: The National... activities regulated under the Antarctic Conservation Act of 1978. NSF has published regulations under the...
78 FR 26777 - Technological Advisory Council Recommendation for Improving Receiver Performance
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-08
... paper makes note that an interference limits policy approach may not be appropriate in all cases. Are.... SUMMARY: The FCC's Technological Advisory Council (TAC) has been tasked to study the role of receivers in.../ecfs2/ . [ssquf] Paper Filers: Parties who choose to file by paper must file an original and one copy of...
49 CFR Appendix A to Part 210 - Summary of Noise Standards, 40 CFR Part 201
Code of Federal Regulations, 2013 CFR
2013-10-01
... 96 Lmax (fast) Do. All Locomotives Manufactured After 31 December 1979 201.11(b) Stationary, Idle....12(b) Moving 90 Lmax (fast) Do. 201.11(c) and 201.12(c) Additional Requirement for Switcher... Locomotive Noise Exceeds the Receiving Property Limit of 65 L90 (fast) 2 Receiving property 201.11(c...
49 CFR Appendix A to Part 210 - Summary of Noise Standards, 40 CFR Part 201
Code of Federal Regulations, 2011 CFR
2011-10-01
... 96 Lmax (fast) Do. All Locomotives Manufactured After 31 December 1979 201.11(b) Stationary, Idle....12(b) Moving 90 Lmax (fast) Do. 201.11(c) and 201.12(c) Additional Requirement for Switcher... Locomotive Noise Exceeds the Receiving Property Limit of 65 L90 (fast) 2 Receiving property 201.11(c...
49 CFR Appendix A to Part 210 - Summary of Noise Standards, 40 CFR Part 201
Code of Federal Regulations, 2010 CFR
2010-10-01
... 96 Lmax (fast) Do. All Locomotives Manufactured After 31 December 1979 201.11(b) Stationary, Idle....12(b) Moving 90 Lmax (fast) Do. 201.11(c) and 201.12(c) Additional Requirement for Switcher... Locomotive Noise Exceeds the Receiving Property Limit of 65 L90 (fast) 2 Receiving property 201.11(c...
49 CFR Appendix A to Part 210 - Summary of Noise Standards, 40 CFR Part 201
Code of Federal Regulations, 2012 CFR
2012-10-01
... 96 Lmax (fast) Do. All Locomotives Manufactured After 31 December 1979 201.11(b) Stationary, Idle....12(b) Moving 90 Lmax (fast) Do. 201.11(c) and 201.12(c) Additional Requirement for Switcher... Locomotive Noise Exceeds the Receiving Property Limit of 65 L90 (fast) 2 Receiving property 201.11(c...
49 CFR Appendix A to Part 210 - Summary of Noise Standards, 40 CFR Part 201
Code of Federal Regulations, 2014 CFR
2014-10-01
... 96 Lmax (fast) Do. All Locomotives Manufactured After 31 December 1979 201.11(b) Stationary, Idle....12(b) Moving 90 Lmax (fast) Do. 201.11(c) and 201.12(c) Additional Requirement for Switcher... Locomotive Noise Exceeds the Receiving Property Limit of 65 L90 (fast) 2 Receiving property 201.11(c...
Hanford Atomic Products Operation monthly report, January 1955
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1955-02-21
This document presents a summary of work and progress at the Hanford Engineer Works for January 1955. The report is divided into sections by department. A plant wide general summary is included at the beginning of the report, after which the departmental summaries begin. The Manufacturing Department reports plant statistics, and summaries for the Metal Preparation, Reactor and Separation sections. The Engineering Department`s section summarizes work for the Technical Design, and Project Sections. Costs for the various departments are presented in the Financial department`s summary. The Medical, Radiological Sciences, Utilities and General Services, Employee and Public Relations, and Community Realmore » Estate and Services departments have sections presenting their monthly statistics, work, progress, and summaries.« less
Hanford Atomic Products Operation monthly report for April 1955
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1955-05-23
This document presents a summary of work and progress at the Hanford Engineer Works for April 1955. The report is divided into sections by department. A plant wide general summary is included at the beginning of the report, after which the departmental summaries begin. The Manufacturing Department reports plant statistics, and summaries for the Metal Preparation, Reactor and Separation sections. The Engineering Department`s section summarizes work for the Technical, Design, and Project Sections. Costs for the various departments are presented in the Financial Department`s summary. The Medical, Radiological Sciences, Utilities and General Services, Employee and Public Relations, and Community Realmore » Estate and Services departments have sections presenting their monthly statistics, work, progress, and summaries.« less
Monthly report Hanford Atomic Products Operation, July 1954
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1954-08-20
This document presents a summary of work and progress at the Hanford Engineer Works for July 1954. The report is divided into sections by department. A plant wide general summary is included at the beginning of the report, after which the departmental summaries begin. The Manufacturing Department reports plant statistics, and summaries for the Metal Preparation, Reactor and Separation sections. The Engineering Department`s section summarizes work for the Technical, Design, and Project sections. Costs for the various departments are presented in the Financial Department`s summary. The Medical, Radiological Sciences, Utilities and General Services, Employee and Public Relations, and Community Realmore » Estate and Services Departments have sections presenting their monthly statistics, work, progress, and summaries.« less
Hanford Atomic Products Operation monthly report, August 1956
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1956-09-28
This document presents a summary of work and progress at the Hanford Engineer Works for August 1956. The report is divided into sections by department. A plant wide general summary is included at the beginning of the report, after which the departmental summaries begin. The Manufacturing Department reports plant statistics, and summaries for the Metal Preparation, Reactor and Separation sections. The Engineering Department`s section summarizes work for the Technical, Design, and Project Sections. Costs for the various departments are presented in the Financial Department`s summary. The Medical, Radiological Sciences, Utilities and General Sciences, Employee and Public Relations, and Community Realmore » Estate and Services departments have sections presenting their monthly statistics, work, progress, and summaries.« less
Hanford Atomic Products Operation monthly report for May 1956
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1956-06-21
This document presents a summary of work and progress at the Hanford Engineer Works for May, 1956. The report is divided into sections by department. A plant wide general summary is included at the beginning of the report, after which the departmental summaries begin. The Manufacturing department reports plant statistics, and summaries for the Metal Preparation, Reactor and Separation sections. The Engineering Department`s section summarizes work for the Technical, Design, and Project Sections. Costs for the various departments are presented in the financial Department`s summary. The Medical, Radiological Sciences, Utilities and General Services, Employee and Public Relations, and Community Realmore » Estate and Services departments have sections presenting their monthly statistics, work, progress, and summaries.« less
Hanford Atomic Products Operation monthly report, September 1955
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1955-10-27
This document presents a summary of work and progress at the Hanford Engineer Works for September 1955. The report is divided into sections by department. A plant wide general summary is included at the beginning of the report, after which the departmental summaries begin. The Manufacturing Department reports plant statistics, and summaries for the Metal Preparation, Reactor and Separation sections. The Engineering Department`s section summarizes work for the Technical, Design, and Project Sections. Costs for the various departments are presented in the Financial Department`s summary. The Medical, Radiological Sciences, Utilities and General Services, Employee and Public Relations, and Community Realmore » Estate and Services departments have sections presenting their monthly statistics, work, progress, and summaries.« less
Hanford Atomic Products Operation monthly report, March 1955
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1955-04-20
This document presents a summary of work and progress at the Hanford Engineer Works for March 1955. The report is divided into sections by department. A plant wide general summary is included at the beginning of the report, after which the departmental summaries begin. The Manufacturing Department reports plant statistics, and summaries for the Metal Preparation, Reactor and Separation sections. The Engineering Department`s section summarizes work for the Technical, Design, and Project Sections. Costs for the various departments are presented in the Financial Department`s summary. The Medical, Radiological Sciences, Utilities and General Services, Employee and Public Relations, and Community Realmore » Estate and Services departments have sections presenting their monthly statistics, work, progress, and summaries.« less
Hanford Atomic Products Operation monthly report, November 1955
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1955-12-30
This document presents a summary of work and progress at the Hanford Engineer Works for November 1955. The report is divided into sections by department. A plant wide general summary is included at the beginning of the report, after which the departmental summaries begin. The Manufacturing Department reports plant statistics, and summaries for the Metal Preparation, Reactor and Separation sections. The Engineering Department`s section summarizes work for the Technical, Design, and Project Sections. Costs for the various departments are presented in the Financial Department`s summary. The Medical, Radiological Sciences, Utilities and General Services, Employee and Public Relations, and Community Realmore » Estate and Services departments have sections presenting their monthly statistics, work, progress, and summaries.« less
Hanford Atomic Products Operation monthly report, August 1955
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1955-09-27
This document presents a summary of work and progress at the Hanford Engineer Works for August 1955. The report is divided into sections by department. A plant wide general summary is included at the beginning of the report, after which the departmental summaries begin. The Manufacturing Department reports plant statistics, and summaries for the Metal Preparation, Reactor and Separation sections. The Engineering Department`s section summarizes work for the Technical, Design, and Project Sections. Costs for the various departments are presented in the Financial Department`s summary. The Medical, Radiological Sciences, Utilities and General Sciences, Employee and Public Relations, and Community Realmore » Estate and Services departments have sections presenting their monthly statistics, work, progress, and summaries.« less
Hanford Atomic Products Operation monthly report for December 1955
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1956-01-30
This document presents a summary of work and progress at the Hanford Engineer Works for December 1955. The report is divided into sections by department. A plant wide general summary is included at the beginning of the report, after which the departmental summaries begin. The Manufacturing Department reports plant statistics, and summaries for the Metal Preparation, Reactor and Separation sections. The Engineering Department`s section summarizes work for the Technical, Design, and Project Sections. Costs for the various departments are presented in the Financial Department`s summary. The Medical, Radiological Sciences, Utilities and General Services, Employee and Public Relations, and Community Realmore » Estate and Services departments have sections presenting their monthly statistics, work, progress, and summaries.« less
Hanford Atomic Products Operation monthly report, October 1955
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1955-11-30
This document presents a summary of work and progress at the Hanford Engineer works for October, 1955. The report is divided into sections by department. A plant wide general summary is included at the beginning of the report, after which the departmental summaries begin. The Manufacturing Department reports plant statistics, and summaries for the Metal Preparation, Reactor and Separation sections. The Engineering Department`s section summarizes work for the Technical, Design, and Project Sections. Costs for the various departments are presented in the Financial Department`s summary. The Medical, Radiological Sciences, Utilities and General Services, Employee and Public Relations, and community Realmore » Estate and Services departments have sections presenting their monthly statistics, work, progress, and summaries.« less
Hanford Atomic Products for Operation monthly report, February 1955
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1955-03-18
This document presents a summary of work and progress at the Hanford Engineer Works for February 1955. The report is divided into sections by department. A plant wide general summary is included at the beginning of the report, after which the departmental summaries begin. The Manufacturing Department reports plant statistics, and summaries for the Metal Preparation, Reactor and Separation sections. The Engineering Department`s section summarizes work for the Technical, Design, and Project Sections. Costs for the various departments are presented in the Financial Department`s summary. The Medical, Radiological Sciences, Utilities and General Services, Employee and Public Relations, and Community Realmore » Estate and Services departments have sections presenting their monthly statistics, work, progress, and summaries.« less
Hanford Atomic Products Operation monthly report, May 1955
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1955-06-23
This document presents a summary of work and progress at the Hanford Engineer Works for May 1955. The report is divided into sections by department. A plant wide general summary is included at the beginning of the report, after which the departmental summaries begin. The Manufacturing Department reports plant statistics, and summaries for the Metal Preparation, Reactor and Separation sections. The Engineering Department`s section summarizes work for the Technical, Design, and Project Sections. Costs for the various departments are presented in the Financial Department`s summary. The Medical, Radiological Sciences, Utilities and General Services, Employee and Public Relations, and Community Realmore » Estate and Services departments have sections presenting their monthly statistics, work, progress, and summaries.« less
Hanford Atomic Products Operation monthly report, July 1955
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1955-08-26
This document presents a summary of work and progress at the Hanford Engineer Works for July 1955. The report is divided into sections by department. A plant wide general summary is included at the beginning of the report, after which the departmental summaries begin. The Manufacturing Department reports plant statistics, and summaries for the Metal Preparation, Reactor and Separation sections. The Engineering Department`s section summarizes work for the Technical, Design, and Project sections. Costs for the various departments are presented in the Financial Department`s summary. The Medical, Radiological Sciences, Utilities and General Services, Employee and Public Relations, and Community Realmore » Estate and services departments have sections presenting their monthly statistics, work, progress, and summaries.« less
Hanford Atomic Products Operation monthly report, October 1954
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1954-11-24
This document presents a summary of work and progress at the Hanford Engineer Works for October 1954. The report is divided into sections by department. A plant wide general summary is included at the beginning of the report, after which the departmental summaries begin. The Manufacturing Department reports plant statistics, and summaries for the Metal Preparation, Reactor and Separation sections. The Engineering Department`s section summarizes work for the Technical, Design, and Project Sections. Costs for the various departments are presented in the Financial Department`s summary. The Medical, Radiological Sciences, Utilities and General Services, Employee and Public Relations, and Community Realmore » Estate and Services departments have sections presenting their monthly statistics, work, progress, and summaries.« less
Hanford Atomic Products Operation monthly report, December 1954
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1955-01-25
This document presents a summary of work and progress at the Hanford Engineer Works for December 1954. The report is divided into sections by department. A plant wide general summary is included at the beginning of the report, after which the departmental summaries begin. The Manufacturing Department reports plant statistics, and summaries for the Metal Preparation, Reactor and Separation sections. The Engineering Department`s section summarizes work for the Technical, Design, and Project Sections. Costs for the various departments are presented in the Financial Department`s summary. The Medical, Radiological Sciences, Utilities and General Services, Employee and Public Relations, and Community Realmore » Estate and Services departments have sections presenting their monthly statistics, work, progress, and summaries.« less
Hanford Atomic Products Operation monthly report, August 1954
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1954-09-17
This document presents a summary of work and progress at the Hanford Engineer Works for August 1954. The report is divided into sections by department. A plant wide general summary is included at the beginning of the report, after which the departmental summaries begin. The Manufacturing Department report plant statistics, and summaries for the Metal Preparation, Reactor and Separation sections. The Engineering Department`s section summarizes work for the Technical, Design, and Project Sections. Costs for the various departments are presented in the Financial Department`s summary. The Medical, Radiological Sciences, Utilities, and General Services, Employee and Public Relations, and Community Realmore » Estate and Services departments have sections presenting their monthly statistics, work, progress, and summaries.« less
Hanford Atomic Products Operation monthly report, August 1953
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1953-09-18
This document presents a summary of work and progress at the Hanford Engineer Works for August, 1953. The report is divided into sections by department. A plant wide general summary is included at the beginning of the report, after which the departmental summaries begin. The Manufacturing Department reports plant statistics, and summaries for the Metal Preparation, Reactor and Separation sections. The Engineering Department`s section summarizes work for the Technical, Design, and Project Sections. Costs for the various departments are presented in the Financial Department`s summary. The Medical, Radiological Sciences, Utilities and General Services, Employee and Public Relations, and Community Realmore » Estate and Services departments have sections presenting their monthly statistics, work, progress, and summaries.« less
Nursing structures in New Zealand public hospitals: current configurations.
Hughes, Kerri-Ann; Carryer, Jennifer Barbara
2011-02-01
This article reports research reviewing the configuration of nursing leadership in New Zealand public hospitals. It represents an analysis of Phase 1 of a larger study. Leadership in nursing is critical if the profession is to meet the challenges of health services in the 21st century. The research focuses on how leadership in public hospitals is structured at a strategic level. The preliminary summary of findings of this phase of the research show that reporting lines between directors of nursing (DON) and the chief executive officer (CEO) are not always direct, and organizational charts and nursing structures are not readily aligned. Clear financial or budget holding reporting lines by nursing leadership are not easily identified, or are professional and operational accountability lines clearly defined. From 15 total responses received, the organizations are structured differently both organizationally and in the nursing structures.
Tailoring vocabularies for NLP in sub-domains: a method to detect unused word sense.
Figueroa, Rosa L; Zeng-Treitler, Qing; Goryachev, Sergey; Wiechmann, Eduardo P
2009-11-14
We developed a method to help tailor a comprehensive vocabulary system (e.g. the UMLS) for a sub-domain (e.g. clinical reports) in support of natural language processing (NLP). The method detects unused sense in a sub-domain by comparing the relational neighborhood of a word/term in the vocabulary with the semantic neighborhood of the word/term in the sub-domain. The semantic neighborhood of the word/term in the sub-domain is determined using latent semantic analysis (LSA). We trained and tested the unused sense detection on two clinical text corpora: one contains discharge summaries and the other outpatient visit notes. We were able to detect unused senses with precision from 79% to 87%, recall from 48% to 74%, and an area under receiver operation curve (AUC) of 72% to 87%.
1992-07-01
Meeting F. RMA HAZOP - Action Item Summary * Action Item Summary Report dated March 27, 1992 * Weston Response dated May 15, 1992 * Revised Action...Additionally, many of the items pertained to the Operation and Maintenance Manual, which was still being developed. Based on a review of the Revised ...four separate submittals, dated November 5, 1991; February 2, 1992; and March 20, 1992, and May 15, 1992. g Additionally, review of the Revised Draft
1999-09-22
Respiratory system Bronchitis 3107 660 5.2% 1.1% 7.0 8.0 13.2 20.1 20.7 28.2 Digestive system Gastroenteritis and colitis exc. ulcer , of noninf...distribution is unlimited. Summary Problem The medical resources needed to support combat operations are dependent upon the time patients spend within...of patients seen at each level of care is an essential component of efficient resource planning. Objective To obtain summary length of stay
NASA Technical Reports Server (NTRS)
1977-01-01
The results of the first one and one-half years of operation of the STARPAHC system are presented. An operational cost summary analysis is included as well as the following; (1) Medical evaluation results, (2) system usage, and (3) hardware evaluation results.
Testing of a Loop Heat Pipe Subjected to Variable Accelerating Forces
NASA Technical Reports Server (NTRS)
Ku, Jentung; Ottenstein, Laura; Kaya, Tarik; Rogers, Paul; Hoff, Craig
2000-01-01
This paper presents viewgraphs of the functionality of a loop heat pipe that was subjected to variable accelerating forces. The topics include: 1) Summary of LHP (Loop Heat Pipe) Design Parameters; 2) Picture of the LHP; 3) Schematic of Test Setup; 4) Test Configurations; 5) Test Profiles; 6) Overview of Test Results; 7) Start-up; 8) Typical Start-up without Temperature Overshoot; 9) Start-up with a Large Temperature Overshoot; 10) LHP Operation Under Stationary Condition; 11) LHP Operation Under Continuous Acceleration; 12) LHP Operation Under Periodic Acceleration; 13) Effects of Acceleration on Temperature Oscillation and Hysteresis; 14) Temperature Oscillation/Hysteresis vs Spin Rate; and 15) Summary.
An approach to a real-time distribution system
NASA Technical Reports Server (NTRS)
Kittle, Frank P., Jr.; Paddock, Eddie J.; Pocklington, Tony; Wang, Lui
1990-01-01
The requirements of a real-time data distribution system are to provide fast, reliable delivery of data from source to destination with little or no impact to the data source. In this particular case, the data sources are inside an operational environment, the Mission Control Center (MCC), and any workstation receiving data directly from the operational computer must conform to the software standards of the MCC. In order to supply data to development workstations outside of the MCC, it is necessary to use gateway computers that prevent unauthorized data transfer back to the operational computers. Many software programs produced on the development workstations are targeted for real-time operation. Therefore, these programs must migrate from the development workstation to the operational workstation. It is yet another requirement for the Data Distribution System to ensure smooth transition of the data interfaces for the application developers. A standard data interface model has already been set up for the operational environment, so the interface between the distribution system and the application software was developed to match that model as closely as possible. The system as a whole therefore allows the rapid development of real-time applications without impacting the data sources. In summary, this approach to a real-time data distribution system provides development users outside of the MCC with an interface to MCC real-time data sources. In addition, the data interface was developed with a flexible and portable software design. This design allows for the smooth transition of new real-time applications to the MCC operational environment.
DOT National Transportation Integrated Search
1995-05-01
This report provides a summary on the state of the national mass transit industry by highlighting aggregate financial and operational characteristics and trend information for key statistics and performance indicators. These aggregate data represent ...
National transit summaries and trends for the 1995 National Transit Database report year
DOT National Transportation Integrated Search
1996-12-01
The 1995 National Transit Summaries and Trends (NTST) provides an overview of the national mass transit industry. The NTST highlights the aggregate financial and operational characteristics and trends of mass transit for the 5-year period 1991-1995. ...
Space station executive summary
NASA Technical Reports Server (NTRS)
1972-01-01
An executive summary of the modular space station study is presented. The subjects discussed are: (1) design characteristics, (2) experiment program, (3) operations, (4) program description, and (5) research implications. The modular space station is considered a candidate payload for the low cost shuttle transportation system.
Research and Technology Objectives and Plans (RTOP), summary
NASA Technical Reports Server (NTRS)
1982-01-01
A compilation of summary portions of each of the Research and Technology Operating Plans (RTOPS) used for management review and control of research currently in progress throughout NASA is presented. Subject, technical monitor, responsible NASA organization, and RTOP number indexes are included.
Surgical wound infection rates in Spain: data summary, January 1997 through June 2012.
Díaz-Agero Pérez, Cristina; Robustillo Rodela, Ana; Pita López, María José; López Fresneña, Nieves; Monge Jodrá, Vicente
2014-05-01
The Indicadores Clínicos de Mejora Continua de la Calidad (INCLIMECC) program was established in Spain in 1997. INCLIMECC is a prospective system of health care-associated infection (HAI) surveillance that collects incidence data in surgical and intensive care unit patients. The protocol is based on the National Healthcare Safety Network (NHSN) surveillance system, formerly known as the National Nosocomial Infection Surveillance (NNIS) system, and uses standard infection definitions from the US Centers for Disease Control and Prevention. Each hospital takes part voluntarily and selects the units and surgical procedures to be surveyed. This report is a summary of the data collected between January 1997 and June 2012. A total of 370,015 patients were included, and the overall incidence of surgical wound infection (SWI) was 4.51%. SWI rates are provided by NHSN operating procedure category and NNIS risk index category. More than 27% of the patients received inadequate antibiotic prophylaxis, the main reason being unsuitable duration (57.05% of cases). Today, the INCLIMECC network includes 64 Spanish hospitals. We believe that an HAI surveillance system with trained personnel external to the surveyed unit is a key component not only in infection control and prevention, but also in a quality improvement system. Copyright © 2014. Published by Mosby, Inc.
A general framework for the use of logistic regression models in meta-analysis.
Simmonds, Mark C; Higgins, Julian Pt
2016-12-01
Where individual participant data are available for every randomised trial in a meta-analysis of dichotomous event outcomes, "one-stage" random-effects logistic regression models have been proposed as a way to analyse these data. Such models can also be used even when individual participant data are not available and we have only summary contingency table data. One benefit of this one-stage regression model over conventional meta-analysis methods is that it maximises the correct binomial likelihood for the data and so does not require the common assumption that effect estimates are normally distributed. A second benefit of using this model is that it may be applied, with only minor modification, in a range of meta-analytic scenarios, including meta-regression, network meta-analyses and meta-analyses of diagnostic test accuracy. This single model can potentially replace the variety of often complex methods used in these areas. This paper considers, with a range of meta-analysis examples, how random-effects logistic regression models may be used in a number of different types of meta-analyses. This one-stage approach is compared with widely used meta-analysis methods including Bayesian network meta-analysis and the bivariate and hierarchical summary receiver operating characteristic (ROC) models for meta-analyses of diagnostic test accuracy. © The Author(s) 2014.
ERIC Educational Resources Information Center
Powell, Marjorie; And Others
The final volume in a series of six evaluation reports, this document provides a summary of the results of the evaluation of Project Developmental Continuity (PDC), conducted when the evaluation study's cohort of children had completed grade 1. Begun at 15 sites in 1974 with the purpose of ensuring that disadvantaged children receive continuous…
Transsexual attractions and sexual reassignment surgery: Risks and potential risks
P. Fitzgibbons, Richard
2015-01-01
Transsexual issues and sexual reassignment surgery (SRS) are receiving a great deal of attention and support in the media, schools, and government. Given the early age at which youth seek treatment for transsexual attractions (TSA) and gender dysphoria and given the serious risks associated with such treatment, it is essential that family and youth be advised about these risks and alternative treatment options. Physicians and mental-health professionals have a professional responsibility to know and communicate the serious risks, in particular risk of suicide, that are associated with SRS; the spontaneous resolution of TSA in youth; the psychological conflicts that have been identified in such patients and in their parents; the successful treatment of conflicts associated TSA and the regrets of those who have been through SRS. SRS and gender theory are also viewed from the faith perspective of Pope Francis and Pope Emeritus Benedict XVI. Lay summary: Transsexuals and sex-change operations are receiving a great deal of attention. Young people may seek treatment for transsexual attractions at an early age even though these attractions may go away on their own. Psychological conflicts have been identified in these patients and their parents and may be successfully treated. There are serious risks associated with sex change. They include the risk of depressive illness and suicide. Physicians and mental-health professionals should know these risks and the regrets of those who have been through sex-change operations. These patients and their families also should be informed of other treatment options. PMID:26997675
Kang, Le; Chen, Weijie; Petrick, Nicholas A; Gallas, Brandon D
2015-02-20
The area under the receiver operating characteristic curve is often used as a summary index of the diagnostic ability in evaluating biomarkers when the clinical outcome (truth) is binary. When the clinical outcome is right-censored survival time, the C index, motivated as an extension of area under the receiver operating characteristic curve, has been proposed by Harrell as a measure of concordance between a predictive biomarker and the right-censored survival outcome. In this work, we investigate methods for statistical comparison of two diagnostic or predictive systems, of which they could either be two biomarkers or two fixed algorithms, in terms of their C indices. We adopt a U-statistics-based C estimator that is asymptotically normal and develop a nonparametric analytical approach to estimate the variance of the C estimator and the covariance of two C estimators. A z-score test is then constructed to compare the two C indices. We validate our one-shot nonparametric method via simulation studies in terms of the type I error rate and power. We also compare our one-shot method with resampling methods including the jackknife and the bootstrap. Simulation results show that the proposed one-shot method provides almost unbiased variance estimations and has satisfactory type I error control and power. Finally, we illustrate the use of the proposed method with an example from the Framingham Heart Study. Copyright © 2014 John Wiley & Sons, Ltd.
Conjunction Assessment Techniques and Operational Results from the Magnetospheric Multiscale Mission
NASA Technical Reports Server (NTRS)
Williams, Trevor; Carpenter, Russell; Farahmand, Mitra; Ottenstein, Neil; Demoret, Michael; Godine, Dominic
2017-01-01
This paper will describe the results that have been obtained to date during the MMS mission concerning conjunction assessment. MMS navigation makes use of a weak-signal GPS-based system: this allows signals to be received even when MMS is flying above the GPS orbits, producing a highly accurate determination of the four MMS orbits. This data is downlinked to the MMS Mission Operations Center (MOC) and used by the Flight Dynamics Operations Area (FDOA) for both maneuver design and conjunction assessment. The MMS fly in tetrahedron formations around apogee, in order to collect simultaneous particles and fields science data. The original plan was to fly tetrahedra between 10 and 160 km in size; however, after Phase 1a of the mission, the science team requested that smaller sizes be flown if feasible. After analysis (to be detailed in a companion paper), a new minimum size of 7 km was decided upon. Flying at this reduced scale size makes conjunction assessment between the MMS spacecraft even more important: the methods that are used by the MMS FDOA to address this problem will be described in the paper, and a summary given of the previous analyses that went into the development of these techniques. Details will also be given of operational experiences to date. Finally, two CA mitigation maneuver types that have been designed (but never yet required to actually be performed) will also be outlined.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-12-01
... and Lime AGENCY: Environmental Protection Agency (EPA). ACTION: Denial of petition. SUMMARY: This... object to a Title V operating permit for Carmeuse Stone and Lime (Carmeuse) issued by the Wisconsin...
77 FR 14047 - Guidance for Decommissioning Planning During Operations
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-08
...)-4014, ``Decommissioning Planning During Operations.'' This action is necessary to correct the NRC's... NUCLEAR REGULATORY COMMISSION [NRC-2011-0286] Guidance for Decommissioning Planning During Operations AGENCY: Nuclear Regulatory Commission. ACTION: Draft regulatory guide; correction. SUMMARY: The U...
78 FR 72572 - Operational Contract Support
Federal Register 2010, 2011, 2012, 2013, 2014
2013-12-03
... 0790-AI48 Operational Contract Support AGENCY: Department of Defense (DoD). ACTION: Final rule. SUMMARY: This rule establishes policy, assigns responsibilities, and provides procedures for operational contract support (OCS), including OCS program management, contract support integration, and integration of...
National transit summaries and trends for the 1994 National Transit Database report year
DOT National Transportation Integrated Search
1996-04-01
The 1994 National Transit Summaries and Trends (NTST) provides an overview of the national mass transit industry. The NTST highlights the aggregate financial and operational characteristics and trends of mass transit for the 5-year period 1990-1994 a...
This SOP described the method used to automatically parse analytical data generated from gas chromatography/mass spectrometry (GC/MS) analyses into CTEPP summary spreadsheets and electronically import the summary spreadsheets into the CTEPP study database.
DOT National Transportation Integrated Search
2012-01-01
Traffic lanes set aside for the use of specific categories of vehicles are becoming more common, from dedicated bicycle lanes on urban roadways to managed lanes for carpools and other high occupancy vehicles on Floridas interstate highways. These ...
Summary of stretch and flex program for TxDOT operations : [summary].
DOT National Transportation Integrated Search
2014-06-01
Strain- and sprain-related incidents account for : 40 percent of the total injuries of Texas : Department of Transportation (TxDOT) : employees. Over the past 5 years, the most : common strain or sprain injury was of the lower : back; 50 percent of t...
SUMMARY REPORT: IN-VESSEL COMPOSTING OF MUNICIPAL WASTEWATER SLUDGE
This 177-page Technology Transfer Summary Report highlights design and operating considerations for possible incorporation into future in-vessel and other sludge composting systems. It is not meant to single out one design as superior to another. The document also aims to heighte...
76 FR 46841 - Notice of Proposed Information Collection for 1029-0039
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-03
... Requirements for Reclamation and Operation Plans. DATES: Comments on the proposed information collection must... Requirements for Reclamation and Operation Plans. OMB Control Number: 1029-0039. Summary: Sections 507(b), 508... operations and reclamation plan and establish performance standards for the mining operation. Information...
Telford, Lisa H; Abdullahi, Leila H; Ochodo, Eleanor A; Engel, Mark E
2018-01-01
Introduction Rheumatic heart disease (RHD) is a preventable and treatable chronic condition which persists in many developing countries largely affecting impoverished populations. Handheld echocardiography presents an opportunity to address the need for more cost-effective methods of diagnosing RHD in developing countries, where the disease continues to carry high rates of morbidity and mortality. Preliminary studies have demonstrated moderate sensitivity as well as high specificity and diagnostic odds for detecting RHD in asymptomatic patients. We describe a protocol for a systematic review on the diagnostic performance of handheld echocardiography compared to standard echocardiography using the 2012 World Heart Federation criteria for diagnosing subclinical RHD. Methods and analysis Electronic databases including PubMed, Scopus, Web of Science and EBSCOhost as well as reference lists and citations of relevant articles will be searched from 2012 to date using a predefined strategy incorporating a combination of Medical Subject Heading terms and keywords. The methodological validity and quality of studies deemed eligible for inclusion will be assessed against review specific Quality Assessment of Diagnostic Accuracy Studies 2 criteria and information on metrics of diagnostic accuracy and demographics extracted. Forest plots of sensitivity and specificity as well as scatter plots in receiver operating characteristic (ROC) space will be used to investigate heterogeneity. If possible, a meta-analysis will be conducted to produce summary results of sensitivity and specificity using the Hierarchical Summary ROC method. In addition, a sensitivity analysis will be conducted to investigate the effect of studies with a high risk of bias. Ethics and dissemination Ethics approval is not required for this systematic review of previously published literature. The planned review will provide a summary of the diagnostic accuracy of handheld echocardiography. Results may feed into evidence-based guidelines and should the findings of this review warrant a change in clinical practice, a summary report will be disseminated among leading clinicians and healthcare professionals in the field. PROSPERO registration number CRD42016051261. PMID:29440164
U. S. Naval Forces, Vietnam Monthly Historical Summary for July 1970
1970-09-22
o o- e ... " ......... CURRENT OPERATIONS ......... ............ I* USN OPERATIONS .7 - Operation Sea Float / Tran I-Tung Dao III...Fleet 21......................... .............. 19 VNN OPERATIONS . Tran Hung Dao I............ .................... 21 Tran Hung Dao II...24 Tran Hung Dao V .................................... 28Tran Hung Dao XI 30 Tran Hung Dao XII (Special Operation
Spain, Peter D.; Oeffinger, Kevin C.; Candela, Joanne; McCabe, Mary; Ma, Xiaomei; Tonorezos, Emily S.
2012-01-01
Purpose: Survivors of pediatric and young adult cancer are at increased risk for treatment-related problems. Yet, few survivors receive risk-based care. The treatment summary and care plan are recommended to improve understanding of cancer treatment, potential late effects, and recommended screening. It is unknown whether survivors retain, understand, value, and disseminate the document, and whether it causes worry. Methods: We surveyed 111 adult survivors of pediatric and young adult cancer 1 to 6 weeks after receipt of a one-page treatment summary and care plan (response rate, 96%). Participants answered questions regarding retention, understanding, value, dissemination, concern, and preferences. Results: Participants were majority female (58%), college-educated (60%), diagnosed with cancer before age 21 (76%), on average 18 years from diagnosis (range, 2 to 50 years), and treated with radiation and chemotherapy (61%). Median age was 30 years (range, 18 to 65 years). A majority of participants stated that they understood the treatment summary (95%), retained the document (95%), and valued it (92%). A minority reported that the document caused concern (14%) or wanted more information than the form provided (20%). Although the time between receipt of the document and survey was brief, many described dissemination of the document to their personal circle (44%) or an outside provider (10 [33%] of 30 who saw an outside doctor). Conclusion: A one-page treatment summary and care plan was well-received and did not cause report of undue concern. Additional health-related information was requested by some, and dissemination to outside providers could be improved. PMID:22942816
Spaceborne receivers: Basic principles
NASA Technical Reports Server (NTRS)
Stacey, J. M.
1984-01-01
The underlying principles of operation of microwave receivers for space observations of planetary surfaces were examined. The design philosophy of the receiver as it is applied to operate functionally as an efficient receiving system, the principle of operation of the key components of the receiver, and the important differences among receiver types are explained. The operating performance and the sensitivity expectations for both the modulated and total power receiver configurations are outlined. The expressions are derived from first principles and are developed through the important intermediate stages to form practicle and easily applied equations. The transfer of thermodynamic energy from point to point within the receiver is illustrated. The language of microwave receivers is applied statistics.
75 FR 57328 - Petitions for Exemption; Summary of Petitions Received
Federal Register 2010, 2011, 2012, 2013, 2014
2010-09-20
... more information on the rulemaking process, see the SUPPLEMENTARY INFORMATION section of this document..., except Federal holidays. FOR FURTHER INFORMATION CONTACT: Jan Thor, (425-227-2127), Standardization...
Solar thermochemical processing system and method
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wegeng, Robert S.; Humble, Paul H.; Krishnan, Shankar
A solar thermochemical processing system is disclosed. The system includes a first unit operation for receiving concentrated solar energy. Heat from the solar energy is used to drive the first unit operation. The first unit operation also receives a first set of reactants and produces a first set of products. A second unit operation receives the first set of products from the first unit operation and produces a second set of products. A third unit operation receives heat from the second unit operation to produce a portion of the first set of reactants.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schwantes, Jon M.
2013-05-01
Summary of Students and Projects Sarah Bender The possible improvement of the Multi-Isotope Process (MIP) Monitor by the addition of Compton suppression is investigated for this study. The Compton continuum from the dominant 661.7 keV Cs-137 fission product peak obscures lower energy lines which could be used for spectral and multivariate analysis. A novel Compton suppression system which uses fast, room-temperature materials will be developed using simulation. As opposed to the standard high purity germanium (HPGe) detector suppressed using a thallium-doped sodium iodide (NaI(Tl)) guard detector array, cerium-doped lanthanum bromide (LaBr3) will be used as the primary spectroscopic detector. Formore » Sarah’s Master’s degree, she constructed and validated the unsuppressed detector response of the Pennsylvania State University (PSU)-Compton suppression system. For Sarah’s PhD, she is completing that simulation by including the suppressed operation which will be validated with spent fuel samples. She is also going to use the validation of suppressed operation to predict the detector response of a LaBr3 based Compton suppression system. Richard Clark Richard Clark completed his study this FY of a new technique known as Intrinsic Dosimetry. Intrinsic Dosimetry is the method of measuring total absorbed dose received by the walls of a container holding radioactive material. By considering the total absorbed dose received by a container in tandem with the physical characteristics of the radioactive material housed within that container, this method has the potential to provide enhanced pathway information regarding the history of the container and its radioactive contents. The latest in a series of experiments designed to validate and demonstrate this newly developed tool are reported. Kenneth Dayman The MIP Monitor is an online, non-destructive approach to process monitoring in a nuclear fuel reprocessing facility using gamma spectra taken of process streams and multivariate data analysis to detect anomalies in operation. Last year, Mr. Dayman investigated methods to classify spent nuclear fuel according to both reactor type and burn up based on the constituent nuclide activities, which may be used to more accurately calibrate other models in an analysis scheme in order to improve the accuracy and precision of predictions. He is currently writing up his results for publication and has transitioned to another project with Dr. Derrick Haas at PNNL.« less
Federal Register 2010, 2011, 2012, 2013, 2014
2013-11-21
... 228--Minimum Operational Performance Standards for Unmanned Aircraft Systems AGENCY: Federal Aviation...--Minimum Operational Performance Standards for Unmanned Aircraft Systems. SUMMARY: The FAA is issuing this notice to advise the public of a meeting of RTCA Special Committee 228--Minimum Operational Performance...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-06-25
... 228--Minimum Operational Performance Standards for Unmanned Aircraft Systems AGENCY: Federal Aviation...--Minimum Operational Performance Standards for Unmanned Aircraft Systems. SUMMARY: The FAA is issuing this notice to advise the public of a meeting of RTCA Special Committee 228--Minimum Operational Performance...
77 FR 67319 - Drawbridge Operation Regulation; Lake Champlain, Swanton, VT
Federal Register 2010, 2011, 2012, 2013, 2014
2012-11-09
... Central Railroad. As a result, in 2012, the operating system was modified by adding electric bridge...: Notice of proposed rulemaking. SUMMARY: The Coast Guard proposes to modify the operating schedule that... owner of the bridge has requested to operate the bridge from a remote location, at St. Albans, Vermont...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-02-27
... Operations Final Environmental Impact Statement, Wayne N. Aspinall Unit, Colorado River Storage Project... SUMMARY: The Bureau of Reclamation (Reclamation), the Federal agency responsible for operation of the... Aspinall Unit operations, Gunnison and Montrose Counties, Colorado. DATES: Reclamation will not make a...
SURVEY OF AIR AND GAS CLEANING OPERATIONS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Morgenthaler, A.C.
1959-09-01
An informative summary of air and gas cleaning operations in the Chemicai Processing Department of the Hanfor Atomic Products Operation, Richland, Washington, is presented. Descriptlons of the fundamental components of cleaning systems, their applications, and cost information are included. (R.G.G.)
NASA Technical Reports Server (NTRS)
1982-01-01
A summary of tasks performed on an integrated command, control, communication, and computation system design study is given. The Tracking and Data Relay Satellite System command and control system study, an automated real-time operations study, and image processing work are discussed.
SUMMARY REPORT: THE CAUSES AND CONTROL OF ACTIVATED SLUDGE BULKING AND FOAMING
This 92-page Technology Transfer Summary Report provides reference material on the causes and controls of sludge bulking and foaming in activated sludge treatment that can be readily understood, and it includes sufficient detail to help plant operators control their systems. The ...
77 FR 43535 - Grantee Codes for Certified Radiofrequency Equipment
Federal Register 2010, 2011, 2012, 2013, 2014
2012-07-25
... Radiofrequency Equipment AGENCY: Federal Communications Commission. ACTION: Final rule. SUMMARY: This document... certify new equipment. DATES: Effective August 24, 2012. FOR FURTHER INFORMATION CONTACT: Hugh Van Tuyl... may also be downloaded at: www.fcc.gov . Summary of the Order 1. The Commission operates an equipment...
2017-03-01
Executive Summary is a product of the Defense Science Board (DSB). The DSB is a Federal Advisory Committee established to provide independent advice to the...Executive Summary Since 2000, when the Defense Science Board concluded space superiority was absolutely essential in achieving global awareness, information...control, critical enabling doctrine, and policy concepts. From April 2015 through September 2016, the Task Force received more than 40 briefings from
Zur, RM; Roy, LM; Ito, S; Beyene, J; Carew, C; Ungar, WJ
2016-01-01
Thiopurine S-methyltransferase (TPMT) deficiency increases the risk of serious adverse events in persons receiving thiopurines. The objective was to synthesize reported sensitivity and specificity of TPMT phenotyping and genotyping using a latent class hierarchical summary receiver operating characteristic meta-analysis. In 27 studies, pooled sensitivity and specificity of phenotyping for deficient individuals was 75.9% (95% credible interval (CrI), 58.3–87.0%) and 98.9% (96.3–100%), respectively. For genotype tests evaluating TPMT*2 and TPMT*3, sensitivity and specificity was 90.4% (79.1–99.4%) and 100.0% (99.9–100%), respectively. For individuals with deficient or intermediate activity, phenotype sensitivity and specificity was 91.3% (86.4–95.5%) and 92.6% (86.5–96.6%), respectively. For genotype tests evaluating TPMT*2 and TPMT*3, sensitivity and specificity was 88.9% (81.6–97.5%) and 99.2% (98.4–99.9%), respectively. Genotyping has higher sensitivity as long as TPMT*2 and TPMT*3 are tested. Both approaches display high specificity. Latent class meta-analysis is a useful method for synthesizing diagnostic test performance data for clinical practice guidelines. PMID:27217052
Hayashida, Kei; Kondo, Yutaka; Hara, Yoshitaka; Aihara, Morio; Yamakawa, Kazuma
2017-03-06
Early diagnosis and immediate therapeutic intervention, including appropriate antibiotic therapy and goal-directed resuscitation, are necessary to reduce mortality in patients with sepsis. However, a single clinical or biological marker indicative of sepsis has not been adopted unanimously. Although procalcitonin and presepsin are promising biomarkers that can effectively differentiate between sepsis/infection and systemic inflammatory response syndrome of non-infectious origin, little is known about which marker is superior. We will conduct a systematic review and meta-analysis of procalcitonin and presepsin for the diagnosis of sepsis/infection in critically ill adult patients. The primary objective is to evaluate the diagnostic accuracy of these 2 biomarkers to a reference standard of sepsis/infection and to compare the diagnostic accuracy with each other. We will search electronic bibliographic databases such as MEDLINE, EMBASE and Cochrane Central Register of Controlled Trials for retrospective and prospective diagnostic test studies. We will assign 2 reviewers to review all collected titles and associated abstracts, review full articles, and extract study data. We will use the Quality of Diagnostic Accuracy Studies-II tool to report study characteristics and to evaluate methodological quality. If pooling is possible, we will use bivariate random effects and hierarchical summary receiver operating characteristic (ROC) models to calculate parameter estimates to output summary ROCs, pooled sensitivity and specificity data, and 95% CIs around the summary operating point. We will also assess heterogeneity via clinical and methodological subgroup and sensitivity analyses. This systematic review will provide guidance on the triage of these tests, help to determine whether existing tests should be revised or replaced, and may also identify knowledge gaps in sepsis diagnosis that could direct further research in the field. Research ethics is not required for this review. The findings will be reported at conferences and in peer-reviewed publications. CRD42016035784. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
Environmental Surveillance at Los Alamos during 2007
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
Environmental Surveillance at Los Alamos reports are prepared annually by the Los Alamos National Laboratory (the Laboratory) Environmental Directorate, as required by US Department of Energy Order 450.1, General Environmental Protection Program, and US Department of Energy Order 231.1A, Environment, Safety, and Health Reporting. These annual reports summarize environmental data that are used to determine compliance with applicable federal, state, and local environmental laws and regulations, executive orders, and departmental policies. Additional data, beyond the minimum required, are also gathered and reported as part of the Laboratory’s efforts to ensure public safety and to monitor environmental quality at and nearmore » the Laboratory. Chapter 1 provides an overview of the Laboratory’s major environmental programs and explains the risks and the actions taken to reduce risks at the Laboratory from environmental legacies and waste management operations. Chapter 2 reports the Laboratory’s compliance status for 2007. Chapter 3 provides a summary of the maximum radiological dose the public and biota populations could have potentially received from Laboratory operations and discusses chemical exposures. The environmental surveillance and monitoring data are organized by environmental media (Chapter 4, air; Chapters 5 and 6, water and sediments; Chapter 7, soils; and Chapter 8, foodstuffs and biota) in a format to meet the needs of a general and scientific audience. Chapter 9 provides a summary of the status of environmental restoration work around LANL. A glossary and a list of acronyms and abbreviations are in the back of the report. Appendix A explains the standards for environmental contaminants, Appendix B explains the units of measurements used in this report, Appendix C describes the laboratory’s technical areas and their associated programs, and Appendix D provides web links to more information. In printed copies of this report or Executive Summary, we have also enclosed a compact disc with a copy of the full report in Adobe Acrobat (PDF) form and detailed supplemental tables of data from 2007 in Microsoft Excel format. These files are also available for download from the web (http://www.lanl.gov/community-environment/environmental- stewardship/environmental-report.php).« less
Radcliff, Kris; Kepler, Christopher; Hilibrand, Alan; Rihn, Jeffrey; Zhao, Wenyan; Lurie, Jon; Tosteson, Tor; Vaccaro, Alexander; Albert, Todd; Weinstein, James
2013-01-01
Summary of Background Data Lumbar spinal stenosis is a common incidental finding among adults over the age of 60, The use of ESI in these patients is common, although there is little evidence in the literature to demonstrate the long-term benefit of ESI in the treatment of lumbar stenosis. Objective The hypothesis of this study was that patients who received epidural steroid injections (ESI) during initial treatment as part of the Spine Patient Outcomes Research Trial (SPORT) would have improved clinical outcomes and a lower rate of crossover to surgery compared to patients who did not receive ESI. Methods Patients with lumbar spinal stenosis who received epidural steroid injections within the first three months of enrollment in SPORT (ESI) were compared to patients who did not receive epidural injections during the first three months of the study (No ESI). Results There were 69 ESI patients and 207 No-ESI patients. There were no significant differences in demographic factors, baseline clinical outcome scores, or operative details although there was a significant increase in baseline preference for nonsurgical treatment among ESI patients (62% vs. 33%, p <0.001). There was an average 26 minute increase in operative time and an increased length of stay by 0.9 days among the ESI patients who ultimately underwent surgical treatment. Averaged over four years, there was significantly less improvement in SF36 PF among surgically treated ESI patients (ESI 14.8 vs. No-ESI 22.5, p=0.025). In addition, there was also significantly less improvement among the nonsurgically treated patients in SF36 BP (ESI 7.3 vs. No-ESI 16.7, p=0.007) and SF36 PF (ESI 5.5 vs. No-ESI 15.2, p=0.009). Of the patients assigned to surgical treatment, there was a significantly increased crossover to nonsurgical treatment among patients who received an ESI (ESI 33% vs. No ESI 11%, p=0.012). Of the patients assigned to non-operative treatment, there was a significantly increased crossover to surgical treatment in the ESI patients (ESI 58% vs. No ESI 32%, p=0.003). Conclusion Despite equivalent baseline status, ESI were associated with significantly less improvement at four years among all patients with spinal stenosis in SPORT. Furthermore, ESI were associated with longer duration of surgery and longer hospital stay. There was no improvement in outcome with ESI whether patients were treated surgically or nonsurgically. PMID:23238485
Environmental surveillance at Los Alamos during 2008
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fuehne, David; Gallagher, Pat; Hjeresen, Denny
2009-09-30
Environmental Surveillance at Los Alamos reports are prepared annually by the Los Alamos National Laboratory (the Laboratory) Environmental Programs Directorate, as required by US Department of Energy Order 450.1, General Environmental Protection Program, and US Department of Energy Order 231.1A, Environment, Safety, and Health Reporting. These annual reports summarize environmental data that are used to determine compliance with applicable federal, state, and local environmental laws and regulations, executive orders, and departmental policies. Additional data, beyond the minimum required, are also gathered and reported as part of the Laboratory’s efforts to ensure public safety and to monitor environmental quality at andmore » near the Laboratory. Chapter 1 provides an overview of the Laboratory’s major environmental programs and explains the risks and the actions taken to reduce risks at the Laboratory from environmental legacies and waste management operations. Chapter 2 reports the Laboratory’s compliance status for 2007. Chapter 3 provides a summary of the maximum radiological dose the public and biota populations could have potentially received from Laboratory operations and discusses chemical exposures. The environmental surveillance and monitoring data are organized by environmental media (Chapter 4, air; Chapters 5 and 6, water and sediments; Chapter 7, soils; and Chapter 8, foodstuffs and biota) in a format to meet the needs of a general and scientific audience. Chapter 9 provides a summary of the status of environmental restoration work around LANL. A glossary and a list of acronyms and abbreviations are in the back of the report. Appendix A explains the standards for environmental contaminants, Appendix B explains the units of measurements used in this report, Appendix C describes the Laboratory’s technical areas and their associated programs, and Appendix D provides web links to more information.« less
75 FR 37879 - Petitions for Exemption; Summary of Petitions Received
Federal Register 2010, 2011, 2012, 2013, 2014
2010-06-30
... more information on the rulemaking process, see the SUPPLEMENTARY INFORMATION section of this document... Federal holidays. FOR FURTHER INFORMATION CONTACT: Jan Thor, (425-227-2127), Standardization Branch, ANM...
75 FR 15771 - Petitions for Exemption; Summary of Petitions Received
Federal Register 2010, 2011, 2012, 2013, 2014
2010-03-30
... more information on the rulemaking process, see the SUPPLEMENTARY INFORMATION section of this document... Federal holidays. FOR FURTHER INFORMATION CONTACT: Jan Thor, (425-227-2127), Standardization Branch, ANM...
75 FR 26843 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2010-05-12
... more information on the rulemaking process, see the SUPPLEMENTARY INFORMATION section of this document... Federal holidays. FOR FURTHER INFORMATION CONTACT: Jan Thor, (425-227-2127), Standardization Branch, ANM...
77 FR 1782 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2012-01-11
... any personal information you provide. Using the search function of our docket web site, anyone can... systems without giving approval for automatic activation devices (AAD). Parachute Labs provides...
Interoperability Assets for Patient Summary Components: A Gap Analysis.
Heitmann, Kai U; Cangioli, Giorgio; Melgara, Marcello; Chronaki, Catherine
2018-01-01
The International Patient Summary (IPS) standards aim to define the specifications for a minimal and non-exhaustive Patient Summary, which is specialty-agnostic and condition-independent, but still clinically relevant. Meanwhile, health systems are developing and implementing their own variation of a patient summary while, the eHealth Digital Services Infrastructure (eHDSI) initiative is deploying patient summary services across countries in the Europe. In the spirit of co-creation, flexible governance, and continuous alignment advocated by eStandards, the Trillum-II initiative promotes adoption of the patient summary by engaging standards organizations, and interoperability practitioners in a community of practice for digital health to share best practices, tools, data, specifications, and experiences. This paper compares operational aspects of patient summaries in 14 case studies in Europe, the United States, and across the world, focusing on how patient summary components are used in practice, to promote alignment and joint understanding that will improve quality of standards and lower costs of interoperability.
STS-1 operational flight profile. Volume 6: Abort analysis
NASA Technical Reports Server (NTRS)
1980-01-01
The abort analysis for the cycle 3 Operational Flight Profile (OFP) for the Space Transportation System 1 Flight (STS-1) is defined, superseding the abort analysis previously presented. Included are the flight description, abort analysis summary, flight design groundrules and constraints, initialization information, general abort description and results, abort solid rocket booster and external tank separation and disposal results, abort monitoring displays and discussion on both ground and onboard trajectory monitoring, abort initialization load summary for the onboard computer, list of the key abort powered flight dispersion analysis.
Operations summary for the convection and moisture experiment (CAMEX)
NASA Technical Reports Server (NTRS)
Griffin, V. L.; Guillory, A. R.; Susko, M.; Arnold, J. E.
1994-01-01
During the fall of 1993, NASA sponsored a field program called the Convection and Moisture Experiment (CAMEX) at Wallops Island, Virginia. CAMEX was a multidisciplinary experiment design to measure the three dimensional moisture fields over Wallops Island and to characterize the multifrequency radiometric signature of tropical convection over the Gulf Stream and southeastern Atlantic Ocean. This document summarizes the daily CAMEX activities, including ground and aircraft (NASA ER-2) operations, and includes 'quick-look' summaries of data acquisition along with data examples provided by the various CAMEX PI's.
Mars Surface Operations via Low-Latency Telerobotics from Phobos
NASA Technical Reports Server (NTRS)
Wright, Michael; Lupisella, Mark
2016-01-01
To help assess the feasibility and timing of Low-Latency Telerobotics (LLT) operations on Mars via a Phobos telecommand base, operations concepts (ops cons) and timelines for several representative sequences for Mars surface operations have been developed. A summary of these LLT sequences and timelines will be presented, along with associated assumptions, operational considerations, and challenges.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-02-08
... ferry operations. The information to be collected will be used to produce a descriptive database of existing ferry operations. A summary report of survey findings will be published on the BTS Web page. The... conducted a survey of approximately 250 ferry operators to identify: (1) Existing ferry operations including...
NASA Technical Reports Server (NTRS)
1983-01-01
Orbital Transfer Vehicle (OTV) servicing study scope, propellant transfer, storage and reliquefaction technology development missions (TDM), docking and berthing TDM, maintenance TDM, OTV/payload integration TDM, combined TDMS design, summary space station accomodations, programmatic analysis, and TDM equipment operational usage are discussed.
Public Schooling in Southeast Wisconsin: 2013-2014 [Summary
ERIC Educational Resources Information Center
Yeado, Joe; Schmidt, Jeff; Hart, Rebecca; Henken, Rob
2014-01-01
This summary from the "Public Schooling in Southeast Wisconsin: 2013-2014" full report presents the school district performance in a pull-out format. Definitions are provided for the column heading: (1) Total Operations Spending, (2) Property Tax Revenue, (3) Total Enrollment; (4) One-Year Change in Enrollment, (5) Minority Enrollment,…
Research and Technology Objectives and Plans Summary (RTOPS)
NASA Technical Reports Server (NTRS)
1979-01-01
A compilation of the summary portions of each of the Research and Technology Operating Plans (RTOP) used for management review and control of research currently in progress throughout NASA is presented along with citations and abstracts of the RTOPs. Indexes include: subject; technical monitor; responsible NASA organization; and RTOP number.
The Inaugural Report of the Global Maritime and Air Communities of Interest Intelligence Enterprises
2009-11-01
iii Executive Summary...and recommending changes to authorities, responsibilities, programs, resources, and operations of the enterprise members. iv Executive Summary...furthered that goal by developing a vision and executing a strategy to rapidly create an integrated maritime and air intelligence capability that
40 CFR Table 3 to Subpart Jj of... - Summary of Emission Limits
Code of Federal Regulations, 2010 CFR
2010-07-01
... to Subpart JJ of Part 63 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... (CONTINUED) National Emission Standards for Wood Furniture Manufacturing Operations Pt. 63, Subpt. JJ, Table 3 Table 3 to Subpart JJ of Part 63—Summary of Emission Limits Emission point Existing source New...
DOT National Transportation Integrated Search
2003-09-16
The objective of this Hazardous Material (HazMat) Transportation Safety and Security Field Operational Test (FOT) Final Detailed Test Plans evaluation is to measure the impact of technology solutions on the safety, security, and operational efficienc...
76 FR 33400 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2011-06-08
...., Monday through Friday, except Federal holidays. For more information on the rulemaking process, see the...: Jan Thor, (425-227-2127), Standardization Branch, ANM-113, Federal Aviation Administration, 1601 Lind...
Anal Cancer Prevention (PDQ®)—Patient Version
Anal cancer prevention includes avoiding risk factors like the human papillomavirus (HPV) and taking protective steps like receiving the HPV vaccine. Learn more about preventing anal cancer in this expert-reviewed summary.
77 FR 22379 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2012-04-13
... seeks relief to allow pilots to substitute crosswind component and braking action restrictions, along with a requirement to utilize automatic landing and approach coupler equipment, at the destination and...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Weber, E.R.
1983-09-01
The preliminary design of a solar central receiver repowered gas/oil fired steam-Rankine cycle electric power generation plant was completed. The design is based on a central receiver technology using molten salt (60% NaNO/sub 3/, 40% KNO/sub 3/, by weight) for the heat transport and thermal storage fluid. Unit One of APS's Saguaro power plant located 43 km (27 mi) northwest of Tucson, AZ, is to be repowered. The selection of both the site and the molten salt central receiver promotes a near-term feasibility demonstration and cost-effective power production from an advanced solar thermal technology. The recommended system concept is tomore » repower the existing electric power generating system at the minimum useful level (66 MW/sub e/ gross) using a field of 4850 Martin Marietta second-generation (58.5 m/sup 2/) heliostats and a storage capacity of 4.0 hours. The storage capacity will be used to optimize dispatch of power to the utility system. The preliminary design was based on the use of the systems approach to design where the overall project was divided into systems, each of which is clearly bounded, and performs specific functions. The total project construction cost was estimated to be 213 million in 1983 dollars. The plant will be capable of displacing fossil energy equivalent to 2.4 million barrels of No. 6 oil in its first 10 years of operation.« less
Jordan, Denis; Steiner, Marcel; Kochs, Eberhard F; Schneider, Gerhard
2010-12-01
Prediction probability (P(K)) and the area under the receiver operating characteristic curve (AUC) are statistical measures to assess the performance of anesthetic depth indicators, to more precisely quantify the correlation between observed anesthetic depth and corresponding values of a monitor or indicator. In contrast to many other statistical tests, they offer several advantages. First, P(K) and AUC are independent from scale units and assumptions on underlying distributions. Second, the calculation can be performed without any knowledge about particular indicator threshold values, which makes the test more independent from specific test data. Third, recent approaches using resampling methods allow a reliable comparison of P(K) or AUC of different indicators of anesthetic depth. Furthermore, both tests allow simple interpretation, whereby results between 0 and 1 are related to the probability, how good an indicator separates the observed levels of anesthesia. For these reasons, P(K) and AUC have become popular in medical decision making. P(K) is intended for polytomous patient states (i.e., >2 anesthetic levels) and can be considered as a generalization of the AUC, which was basically introduced to assess a predictor of dichotomous classes (e.g., consciousness and unconsciousness in anesthesia). Dichotomous paradigms provide equal values of P(K) and AUC test statistics. In the present investigation, we introduce a user-friendly computer program for computing P(K) and estimating reliable bootstrap confidence intervals. It is designed for multiple comparisons of the performance of depth of anesthesia indicators. Additionally, for dichotomous classes, the program plots the receiver operating characteristic graph completing information obtained from P(K) or AUC, respectively. In clinical investigations, both measures are applied for indicator assessment, where ambiguous usage and interpretation may be a consequence. Therefore, a summary of the concepts of P(K) and AUC including brief and easily understandable proof of their equality is presented in the text. The exposure introduces readers to the algorithms of the provided computer program and is intended to make standardized performance tests of depth of anesthesia indicators available to medical researchers.
Using convolutional decoding to improve time delay and phase estimation in digital communications
Ormesher, Richard C [Albuquerque, NM; Mason, John J [Albuquerque, NM
2010-01-26
The time delay and/or phase of a communication signal received by a digital communication receiver can be estimated based on a convolutional decoding operation that the communication receiver performs on the received communication signal. If the original transmitted communication signal has been spread according to a spreading operation, a corresponding despreading operation can be integrated into the convolutional decoding operation.
NASA Technical Reports Server (NTRS)
Clukey, Steven J.
1991-01-01
The real time Dynamic Data Acquisition and Processing System (DDAPS) is described which provides the capability for the simultaneous measurement of velocity, density, and total temperature fluctuations. The system of hardware and software is described in context of the wind tunnel environment. The DDAPS replaces both a recording mechanism and a separate data processing system. DDAPS receives input from hot wire anemometers. Amplifiers and filters condition the signals with computer controlled modules. The analog signals are simultaneously digitized and digitally recorded on disk. Automatic acquisition collects necessary calibration and environment data. Hot wire sensitivities are generated and applied to the hot wire data to compute fluctuations. The presentation of the raw and processed data is accomplished on demand. The interface to DDAPS is described along with the internal mechanisms of DDAPS. A summary of operations relevant to the use of the DDAPS is also provided.
Reward-Guided Learning with and without Causal Attribution
Jocham, Gerhard; Brodersen, Kay H.; Constantinescu, Alexandra O.; Kahn, Martin C.; Ianni, Angela M.; Walton, Mark E.; Rushworth, Matthew F.S.; Behrens, Timothy E.J.
2016-01-01
Summary When an organism receives a reward, it is crucial to know which of many candidate actions caused this reward. However, recent work suggests that learning is possible even when this most fundamental assumption is not met. We used novel reward-guided learning paradigms in two fMRI studies to show that humans deploy separable learning mechanisms that operate in parallel. While behavior was dominated by precise contingent learning, it also revealed hallmarks of noncontingent learning strategies. These learning mechanisms were separable behaviorally and neurally. Lateral orbitofrontal cortex supported contingent learning and reflected contingencies between outcomes and their causal choices. Amygdala responses around reward times related to statistical patterns of learning. Time-based heuristic mechanisms were related to activity in sensorimotor corticostriatal circuitry. Our data point to the existence of several learning mechanisms in the human brain, of which only one relies on applying known rules about the causal structure of the task. PMID:26971947
Development of a 9.3 micrometer CW LIDAR for the study of atmospheric aerosol
NASA Technical Reports Server (NTRS)
Whiteside, B. N.; Schotland, R. M.
1993-01-01
This report provides a brief summary of the basic requirements to obtain coherent or heterodyne mixing of the optical radiation backscattered by atmospheric aerosols with that from a fixed frequency source. The continuous wave (CW) mode of operation for a coherent lidar is reviewed along with the associated lidar transfer equation. A complete optical design of the three major subsystems of a CW, coherent lidar is given. Lens design software is implemented to model and optimize receiver performance. Techniques for the opto-mechanical assembly and some of the critical tolerances of the coherent lidar are provided along with preliminary tests of the subsystems. Included in these tests is a comparison of the experimental and the theoretical average power signal-to-noise ratio. The analog to digital software used to evaluate the power spectrum of the backscattered signal is presented in the Appendix of this report.
Will Catholic hospitals survive without government reimbursements?
Archer, David L
2017-02-01
This brief essay will begin to address the feasibility of operating a Catholic healthcare system without reimbursement from government healthcare programs such as Medicare and Medicaid. This question stems from the recent ACA/HHS "Nondiscrimination in Health Programs and Activities" final rule. Summary : The average hospital in the United States receives 40-50 percent of its net revenues from governmental sources. Participation in Medicare is contingent upon the hospital having a Medicare provider agreement. Participation in other governmental programs (Medicaid) as well as most commercial insurance is also contingent upon that agreement. Hospitals, including "Catholic" hospitals, cannot survive without a Medicare provider agreement. That agreement may be terminated for non-compliance with Medicare and other governmental regulations such as the recent ACA/HHS "Nondiscrimination in Health Programs and Activities" final rule, which could require "Catholic" hospitals to provide services which violate moral principals of the Church.
NASA Astrophysics Data System (ADS)
Wunderlich, Adam; Goossens, Bart
2014-03-01
The majority of the literature on task-based image quality assessment has focused on lesion detection tasks, using the receiver operating characteristic (ROC) curve, or related variants, to measure performance. However, since many clinical image evaluation tasks involve both detection and estimation (e.g., estimation of kidney stone composition, estimation of tumor size), there is a growing interest in performance evaluation for joint detection and estimation tasks. To evaluate observer performance on such tasks, Clarkson introduced the estimation ROC (EROC) curve, and the area under the EROC curve as a summary figure of merit. In the present work, we propose nonparametric estimators for practical EROC analysis from experimental data, including estimators for the area under the EROC curve and its variance. The estimators are illustrated with a practical example comparing MRI images reconstructed from different k-space sampling trajectories.
Summary of Aqua, Aura, and Terra High Interest Events
NASA Technical Reports Server (NTRS)
Newman, Lauri
2015-01-01
Single-obs tracking Sparsely tracked objects are an unfortunate reality of CARA operations Terra vs. 32081: new track with bad data was included in OD solution for secondary object and risk became high CARA and JSpOC discussed tracking and OSAs threw out the bad data. Event no longer presented high risk based on new OD Improvement: CARA now sends JSpOC a flag indicating when a single obs is included, so OSAs can evaluate if manual update to OD is required. Missing ASW OCMsAura vs. 87178, TCA: 317 at 08:04 UTC. Post-maneuver risk (conjunction was identified in OO results)CARA confirmed with JSpOC that ASW OCMs should have been received in addition to OO OCMsJSpOC corrected the manual error in their script that prevented the data from being delivered to CARAJSpOC QAd their other scripts to ensure this error did not exist in other places.
40 CFR 60.1685 - What if all the certified operators must be temporarily offsite?
Code of Federal Regulations, 2010 CFR
2010-07-01
... onsite. (2) Submit a status report and corrective action summary to the Administrator every 4 weeks... hours, but for 2 weeks or less, and no other certified operator is onsite, the provisionally certified... weeks, and no other certified operator is onsite, the provisionally certified control room operator may...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-03-14
.... 3 and No. 4 Lode Mining Claims Proposed Plan of Operations. The project included mining operations on the lode claims along with associated activities such as road maintenance and construction. The... Mining Claims, Plan of Operations AGENCY: Forest Service, USDA. ACTION: Notice of withdrawal. SUMMARY...
78 FR 66099 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2013-11-04
..., Office of Rulemaking. Petition for Exemption Docket No.: FAA-2013-0818. Petitioner: ELITE Simulation Solutions. Section of 14 CFR Affected: Sec. 61.65(i) Description of Relief Sought: ELITE Simulation...
77 FR 42801 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2012-07-20
...'s awareness of, and participation in, this aspect of FAA's regulatory activities. Neither... promotional and educational flights in a CE-182 aircraft that uses an alternative fuel. [FR Doc. 2012-17715...
75 FR 65396 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2010-10-22
...: You may send comments identified by Docket Number FAA-2010- 1057 using any of the following methods... Rulemaking. Petition for Exemption Docket No.: FAA-2010-1057. Petitioner: Gulfstream Aerospace Corporation...
76 FR 66351 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2011-10-26
...: You may send comments identified by Docket Number FAA-2011- 1084 using any of the following methods...-2011-1084. Petitioner: Era Helicopters, LLC. Section of 14 CFR Affected: Special Federal Aviation...
76 FR 81010 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2011-12-27
... send comments identified by Docket Number FAA-2011- 1044 using any of the following methods: Government... Rulemaking. Petition For Exemption Docket No.: FAA-2011-1044. Petitioner: Sundance Helicopters, Inc. Section...
DOT National Transportation Integrated Search
2003-09-01
In January 2001, the Federal Highway Administration (FHWA) released a solicitation requesting "Cost Sharing Cooperative Agreements" to conduct operational tests to improve efficiencies in the intermodal freight operations and to establish the foundat...
75 FR 31744 - Information Collection; Contract Operations and Administration
Federal Register 2010, 2011, 2012, 2013, 2014
2010-06-04
... Administration AGENCY: Forest Service, USDA. ACTION: Notice; request for comment. SUMMARY: In accordance with the... organizations on a new information collection, Contract Operations and Administration. DATES: Comments must be... INFORMATION: Title: Contract Operations and Administration. OMB Number: 0596-NEW. Expiration Date of Approval...
DOT National Transportation Integrated Search
2003-10-29
The Beta Test and Baseline Data Collection efforts ensured that the test technologies would successfully operate during the field operational test (FOT) in the designed scenario configurations. These efforts also ensured that FOT systems would succes...
Accuracy of i-Scan for Optical Diagnosis of Colonic Polyps: A Meta-Analysis
Guo, Chuan-Guo; Ji, Rui; Li, Yan-Qing
2015-01-01
Background i-Scan is a novel virtual chromoendoscopy system designed to enhance surface and vascular patterns to improve optical diagnostic performance. Numerous prospective studies have been done to evaluate the accuracy of i-Scan in differentiating colonic neoplasms from non-neoplasms. i-Scan could be an effective endoscopic technique for optical diagnosis of colonic polyps. Objective Our aim of this study was to perform a meta-analysis of published data to establish the diagnostic accuracy of i-Scan for optical diagnosis of colonic polyps. Methods We searched PubMed, Medline, Elsevier ScienceDirect and Cochrane Library databases. We used a bivariate meta-analysis following a random effects model to summarize the data and plotted hierarchical summary receiver-operating characteristic (HSROC) curves. The area under the HSROC curve (AUC) serves as an indicator of the diagnostic accuracy. Results The meta-analysis included a total of 925 patients and 2312 polyps. For the overall studies, the area under the HSROC curve was 0.96. The summary sensitivity was 90.4% (95%CI 85%-94.1%) and specificity was 90.9% (95%CI 84.3%-94.9%). In 11 studies predicting polyps histology in real-time, the summary sensitivity and specificity was 91.5% (95%CI 85.7%-95.1%) and 92.1% (95%CI 84.5%-96.1%), respectively, with the AUC of 0.97. For three different diagnostic criteria (Kudo, NICE, others), the sensitivity was 86.3%, 93.0%, 85.0%, respectively and specificity was 84.8%, 94.4%, 91.8%, respectively. Conclusions Endoscopic diagnosis with i-Scan has accurate optical diagnostic performance to differentiate neoplastic from non-neoplastic polyps with an area under the HSROC curve exceeding 0.90. Both the sensitivity and specificity for diagnosing colonic polyps are over 90%. PMID:25978459
DOT National Transportation Integrated Search
2014-05-01
Thefederallymandatedmaterialsclearanceprocessrequiresstatetransportation : agenciestosubjectallconstructionfieldsamplestoqualitycontrol/assurancetestingin : ordertopassstandardizedstateinspections....
Transition to the space shuttle operations era
NASA Technical Reports Server (NTRS)
1985-01-01
The tasks involved in the Space Shuttle Development Program are discussed. The ten major characteristics of an operational Shuttle are described, as well as the changes occurring in Shuttle processing, on-line operations, operations engineering, and support operations. A summary is given of tasks and goals that are being pursued in the effort to create a cost effective and efficient system.
Jayatilleke, Nishamali; Kolliakou, Anna; Ball, Michael; Gorrell, Genevieve; Roberts, Angus; Stewart, Robert
2017-01-01
Objectives We sought to use natural language processing to develop a suite of language models to capture key symptoms of severe mental illness (SMI) from clinical text, to facilitate the secondary use of mental healthcare data in research. Design Development and validation of information extraction applications for ascertaining symptoms of SMI in routine mental health records using the Clinical Record Interactive Search (CRIS) data resource; description of their distribution in a corpus of discharge summaries. Setting Electronic records from a large mental healthcare provider serving a geographic catchment of 1.2 million residents in four boroughs of south London, UK. Participants The distribution of derived symptoms was described in 23 128 discharge summaries from 7962 patients who had received an SMI diagnosis, and 13 496 discharge summaries from 7575 patients who had received a non-SMI diagnosis. Outcome measures Fifty SMI symptoms were identified by a team of psychiatrists for extraction based on salience and linguistic consistency in records, broadly categorised under positive, negative, disorganisation, manic and catatonic subgroups. Text models for each symptom were generated using the TextHunter tool and the CRIS database. Results We extracted data for 46 symptoms with a median F1 score of 0.88. Four symptom models performed poorly and were excluded. From the corpus of discharge summaries, it was possible to extract symptomatology in 87% of patients with SMI and 60% of patients with non-SMI diagnosis. Conclusions This work demonstrates the possibility of automatically extracting a broad range of SMI symptoms from English text discharge summaries for patients with an SMI diagnosis. Descriptive data also indicated that most symptoms cut across diagnoses, rather than being restricted to particular groups. PMID:28096249
A Summary of the Naval Postgraduate School Research Program.
1984-06-01
Administrative Sciences, Operations Research, National Security Affairs, Physics, Electrical Engineering , Meterology, Aeronautics, Oceanography and Mechanical ...Oceans and Major Seas -------------------------------- 290 DEPARTMENT OF MECHANICAL ENGINEERING 291 Mechanical Engineering Department Summary 293...in Buried Pipes Using Sulphur Hexaflouride as a Tracer Gas," American Society of Mechanical Engineers , The Journal of Engineering for Power
Inside the Content: The Breadth and Depth of Early Learning Standards. Executive Summary
ERIC Educational Resources Information Center
Scott-Little, Catherine; Kagan, Sharon Lynn; Frelow, Victoria Stebbins
2005-01-01
This executive summary describes a study that analyzes the content of early learning standards, operationally defined as documents that articulate expectations for children's development and learning during the preschool period (ages three to five years). Standards from 36 states were collected and analyzed to address the following research…
Design of Training Systems Phase I Summary Report.
ERIC Educational Resources Information Center
Lindahl, William H.; And Others
A summary is provided of the status of Phase I of the three-stage project, "Design of Training Systems" (DOTS). The purpose of the overall project is described as being to introduce the technologies of education, psychology, management and operations research into the management of Navy training. Phase I of the effort is designed to…
KEEP Five-Year Summary Report.
ERIC Educational Resources Information Center
Gallimore, Ronald; Tharp, Roland G.
This brief summary outlines the activities and findings of the research and development efforts of the Kamehameha Early Education Program (KEEP) from 1971 to 1976. The paper suggests that the original goals of the program were met and that the initial operating procedures agreed upon by KEEP and the Hawaii State Department of Education were…
ULSGEN (Uplink Summary Generator)
NASA Technical Reports Server (NTRS)
Wang, Y.-F.; Schrock, M.; Reeve, T.; Nguyen, K.; Smith, B.
2014-01-01
Uplink is an important part of spacecraft operations. Ensuring the accuracy of uplink content is essential to mission success. Before commands are radiated to the spacecraft, the command and sequence must be reviewed and verified by various teams. In most cases, this process requires collecting the command data, reviewing the data during a command conference meeting, and providing physical signatures by designated members of various teams to signify approval of the data. If commands or sequences are disapproved for some reason, the whole process must be restarted. Recording data and decision history is important for traceability reasons. Given that many steps and people are involved in this process, an easily accessible software tool for managing the process is vital to reducing human error which could result in uplinking incorrect data to the spacecraft. An uplink summary generator called ULSGEN was developed to assist this uplink content approval process. ULSGEN generates a web-based summary of uplink file content and provides an online review process. Spacecraft operations personnel view this summary as a final check before actual radiation of the uplink data. .
Final safety analysis report for the Ground Test Accelerator (GTA), Phase 2
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1994-10-01
This document is the second volume of a 3 volume safety analysis report on the Ground Test Accelerator (GTA). The GTA program at the Los Alamos National Laboratory (LANL) is the major element of the national Neutral Particle Beam (NPB) program, which is supported by the Strategic Defense Initiative Office (SDIO). A principal goal of the national NPB program is to assess the feasibility of using hydrogen and deuterium neutral particle beams outside the Earth`s atmosphere. The main effort of the NPB program at Los Alamos concentrates on developing the GTA. The GTA is classified as a low-hazard facility, exceptmore » for the cryogenic-cooling system, which is classified as a moderate-hazard facility. This volume consists of failure modes and effects analysis; accident analysis; operational safety requirements; quality assurance program; ES&H management program; environmental, safety, and health systems critical to safety; summary of waste-management program; environmental monitoring program; facility expansion, decontamination, and decommissioning; summary of emergency response plan; summary plan for employee training; summary plan for operating procedures; glossary; and appendices A and B.« less
76 FR 64009 - Drawbridge Operation Regulation; Apponagansett River, Dartmouth, MA
Federal Register 2010, 2011, 2012, 2013, 2014
2011-10-17
... DEPARTMENT OF HOMELAND SECURITY Coast Guard 33 CFR Part 117 [Docket No. USCG-2011-0335] RIN 1625-AA09 Drawbridge Operation Regulation; Apponagansett River, Dartmouth, MA AGENCY: Coast Guard, DHS. ACTION: Final rule. SUMMARY: The Coast Guard has changed the drawbridge operation regulations that govern...
77 FR 35843 - Drawbridge Operation Regulation; Umpqua River, Reedsport, OR
Federal Register 2010, 2011, 2012, 2013, 2014
2012-06-15
... DEPARTMENT OF HOMELAND SECURITY Coast Guard 33 CFR Part 117 [Docket No. USCG-2012-0534] Drawbridge Operation Regulation; Umpqua River, Reedsport, OR AGENCY: Coast Guard, DHS. ACTION: Notice of temporary deviation from regulations. SUMMARY: The Coast Guard has issued a temporary deviation from the operating...
DOT National Transportation Integrated Search
1998-08-19
The existing operational procedure of motor carriers and state enforcement agencies have potentially substantial benefits to gain by integrating Intelligent Transportation System technology into their commercial vehicle operations (ITS/CVO). In parti...
76 FR 23969 - Submission for OMB Review; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2011-04-29
... collection system for the collection of data policy and operational issues related to the Child Nutrition... Nutrition Service Title: Special Nutrition Program Operations Study--Year 1. OMB Control Number: 0584-NEW. Summary of Collections: The objective of the Special Nutrition Program Operations Study (SNPOS) is to...
Optimization of MLS receivers for multipath environments
NASA Technical Reports Server (NTRS)
Mcalpine, G. A.; Highfill, J. H., III
1976-01-01
The design of a microwave landing system (MLS) aircraft receiver, capable of optimal performance in multipath environments found in air terminal areas, is reported. Special attention was given to the angle tracking problem of the receiver and includes tracking system design considerations, study and application of locally optimum estimation involving multipath adaptive reception and then envelope processing, and microcomputer system design. Results show processing is competitive in this application with i-f signal processing performance-wise and is much more simple and cheaper. A summary of the signal model is given.
50 CFR Table 13 to Part 679 - Transfer Form Summary
Code of Federal Regulations, 2013 CFR
2013-10-01
... sablefish, IFQ halibut, or CDQ halibut Transfer of product XXX Registered Buyer IFQ sablefish, IFQ halibut... site to processor. XXX indicates receipt must be issued to each receiver in a dockside sale. XXXX...
50 CFR Table 13 to Part 679 - Transfer Form Summary
Code of Federal Regulations, 2014 CFR
2014-10-01
... sablefish, IFQ halibut, or CDQ halibut Transfer of product XXX Registered Buyer IFQ sablefish, IFQ halibut... site to processor. XXX indicates receipt must be issued to each receiver in a dockside sale. XXXX...
50 CFR Table 13 to Part 679 - Transfer Form Summary
Code of Federal Regulations, 2012 CFR
2012-10-01
... sablefish, IFQ halibut, or CDQ halibut Transfer of product XXX Registered Buyer IFQ sablefish, IFQ halibut... site to processor. XXX indicates receipt must be issued to each receiver in a dockside sale. XXXX...
50 CFR Table 13 to Part 679 - Transfer Form Summary
Code of Federal Regulations, 2011 CFR
2011-10-01
... sablefish, IFQ halibut, or CDQ halibut Transfer of product XXX Registered Buyer IFQ sablefish, IFQ halibut... site to processor. XXX indicates receipt must be issued to each receiver in a dockside sale. XXXX...
78 FR 18961 - Gulf of Mexico Fishery Management Council; Public Meetings
Federal Register 2010, 2011, 2012, 2013, 2014
2013-03-28
... Management for Recreational Red Snapper; discuss Red Snapper 5-year IFQ Review and IFQ Inter-sector Trading... Migratory Pelagic Zones; and, receive a summary of South Atlantic Council Motions and Recommendations for...
75 FR 51525 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-20
... the Regional Airline Association. Section of 14 CFR Affected: Sec. 121.803(c)(3) and Appendix A to... Air Carrier Association, and the Regional Airline Association, on behalf of their passenger airline...
77 FR 65761 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-30
... an explosive or incendiary device; 6. The requirement for a designated location where a bomb or other... case of detonation (least risk bomb location); 7. The requirement that the passenger cabin be designed...
76 FR 10429 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2011-02-24
... information was submitted via phone conversation and in letter form. The petitioner had a conversation with.... Both the Record of Conversation from the phone call and the information submitted by letter are...
76 FR 72494 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2011-11-23
... send comments identified by Docket Number FAA-2011- 1042 using any of the following methods: Government... Exemption Docket No.: FAA-2011-1042. Petitioner: The Boeing Company. Section of 14 CFR Affected: Section 25...
50 CFR Table 13 to Part 679 - Transfer Form Summary
Code of Federal Regulations, 2010 CFR
2010-10-01
... sablefish, IFQ halibut, or CDQ halibut Transfer of product XXX Registered Buyer IFQ sablefish, IFQ halibut... site to processor. XXX indicates receipt must be issued to each receiver in a dockside sale. XXXX...
Summary of External Peer Review and Public Comments and Disposition
This document summarizes the public and external peer review comments that the EPA’s Office of Pollution Prevention and Toxics (OPPT) received for the draft work plan risk assessment for n-Methylpyrrolidone (NMP).
75 FR 10016 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2010-03-04
...: You may send comments identified by Docket Number FAA-2009- 1087 using any of the following methods.... Petition for Exemption Docket No.: FAA-2009-1087. Petitioner: Terrafugia, Inc. Section of 14 CFR Affected...
Preliminary data summary : airport deicing operations (revised)
DOT National Transportation Integrated Search
2000-08-01
The deicing and anti-icing of aircraft and airfield surfaces is required by the Federal : Aviation Administration (FAA) to ensure the safety of passengers; however, when performed : without discharge controls in place, airport deicing operations can ...
77 FR 51699 - Drawbridge Operation Regulation; Cape Fear River, Wilmington, NC
Federal Register 2010, 2011, 2012, 2013, 2014
2012-08-27
... Operation Regulation; Cape Fear River, Wilmington, NC AGENCY: Coast Guard, DHS. ACTION: Notice of temporary deviation from regulations. SUMMARY: The Commander, Fifth Coast Guard District, has issued a temporary [[Page 51700
Generation of Natural-Language Textual Summaries from Longitudinal Clinical Records.
Goldstein, Ayelet; Shahar, Yuval
2015-01-01
Physicians are required to interpret, abstract and present in free-text large amounts of clinical data in their daily tasks. This is especially true for chronic-disease domains, but holds also in other clinical domains. We have recently developed a prototype system, CliniText, which, given a time-oriented clinical database, and appropriate formal abstraction and summarization knowledge, combines the computational mechanisms of knowledge-based temporal data abstraction, textual summarization, abduction, and natural-language generation techniques, to generate an intelligent textual summary of longitudinal clinical data. We demonstrate our methodology, and the feasibility of providing a free-text summary of longitudinal electronic patient records, by generating summaries in two very different domains - Diabetes Management and Cardiothoracic surgery. In particular, we explain the process of generating a discharge summary of a patient who had undergone a Coronary Artery Bypass Graft operation, and a brief summary of the treatment of a diabetes patient for five years.
Koen, Joshua D; Barrett, Frederick S; Harlow, Iain M; Yonelinas, Andrew P
2017-08-01
Signal-detection theory, and the analysis of receiver-operating characteristics (ROCs), has played a critical role in the development of theories of episodic memory and perception. The purpose of the current paper is to present the ROC Toolbox. This toolbox is a set of functions written in the Matlab programming language that can be used to fit various common signal detection models to ROC data obtained from confidence rating experiments. The goals for developing the ROC Toolbox were to create a tool (1) that is easy to use and easy for researchers to implement with their own data, (2) that can flexibly define models based on varying study parameters, such as the number of response options (e.g., confidence ratings) and experimental conditions, and (3) that provides optimal routines (e.g., Maximum Likelihood estimation) to obtain parameter estimates and numerous goodness-of-fit measures.The ROC toolbox allows for various different confidence scales and currently includes the models commonly used in recognition memory and perception: (1) the unequal variance signal detection (UVSD) model, (2) the dual process signal detection (DPSD) model, and (3) the mixture signal detection (MSD) model. For each model fit to a given data set the ROC toolbox plots summary information about the best fitting model parameters and various goodness-of-fit measures. Here, we present an overview of the ROC Toolbox, illustrate how it can be used to input and analyse real data, and finish with a brief discussion on features that can be added to the toolbox.
The average receiver operating characteristic curve in multireader multicase imaging studies
Samuelson, F W
2014-01-01
Objective: In multireader, multicase (MRMC) receiver operating characteristic (ROC) studies for evaluating medical imaging systems, the area under the ROC curve (AUC) is often used as a summary metric. Owing to the limitations of AUC, plotting the average ROC curve to accompany the rigorous statistical inference on AUC is recommended. The objective of this article is to investigate methods for generating the average ROC curve from ROC curves of individual readers. Methods: We present both a non-parametric method and a parametric method for averaging ROC curves that produce a ROC curve, the area under which is equal to the average AUC of individual readers (a property we call area preserving). We use hypothetical examples, simulated data and a real-world imaging data set to illustrate these methods and their properties. Results: We show that our proposed methods are area preserving. We also show that the method of averaging the ROC parameters, either the conventional bi-normal parameters (a, b) or the proper bi-normal parameters (c, da), is generally not area preserving and may produce a ROC curve that is intuitively not an average of multiple curves. Conclusion: Our proposed methods are useful for making plots of average ROC curves in MRMC studies as a companion to the rigorous statistical inference on the AUC end point. The software implementing these methods is freely available from the authors. Advances in knowledge: Methods for generating the average ROC curve in MRMC ROC studies are formally investigated. The area-preserving criterion we defined is useful to evaluate such methods. PMID:24884728
NASA Technical Reports Server (NTRS)
Salomonson, V. V.; Rango, A.
1975-01-01
Various techniques for reducing the satellite data to a form usable by the operational agencies were covered in mini-presentations by the operational satellite snow interpretive personnel. Similar discussions were made by operational agency stream flow forecasters on how satellite-derived snow data could be incorporated into runoff forecasting methods.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-15
... Full Approval of Title V Operating Permits Program; Southern Ute Indian Tribe AGENCY: Environmental Protection Agency (EPA). ACTION: Final rule. SUMMARY: The EPA is promulgating full approval of the Title V Operating Permits Program submitted by the Southern Ute Indian Tribe (Tribe). The Tribe's Title V Operating...
NASA Technical Reports Server (NTRS)
Mehrbach, E.; Turkel, S. H.
1972-01-01
A summary of the findings of the data management group of the orbital operations study is presented. Element interfaces, alternate approaches, design concepts, operational procedures, functional requirements, design influences, and approach selection are described. The following interfacing activities are considered: (1) communications, (2) rendezvous, (3) stationkeeping, and (4) detached element operations.
Summary of Notifiable Infectious Diseases and Conditions - United States, 2015.
Adams, Deborah A; Thomas, Kimberly R; Jajosky, Ruth Ann; Foster, Loretta; Baroi, Gitangali; Sharp, Pearl; Onweh, Diana H; Schley, Alan W; Anderson, Willie J
2017-08-11
The Summary of Notifiable Infectious Diseases and Conditions - United States, 2015 (hereafter referred to as the summary) contains the official statistics, in tabular and graphical form, for the reported occurrence of nationally notifiable infectious diseases and conditions in the United States for 2015. Unless otherwise noted, data are final totals for 2015 reported as of June 30, 2016. These statistics are collected and compiled from reports sent by U.S. state and territories, New York City, and District of Columbia health departments to the National Notifiable Diseases Surveillance System (NNDSS), which is operated by CDC in collaboration with the Council of State and Territorial Epidemiologists (CSTE). This summary is available at https://www.cdc.gov/MMWR/MMWR_nd/index.html. This site also includes summary publications from previous years.
Summary of Notifiable Infectious Diseases and Conditions - United States, 2013.
Adams, Deborah; Fullerton, Kathleen; Jajosky, Ruth; Sharp, Pearl; Onweh, Diana; Schley, Alan; Anderson, Willie; Faulkner, Amanda; Kugeler, Kiersten
2015-10-23
The Summary of Notifiable Infectious Diseases and Condition-United States, 2013 (hereafter referred to as the summary) contains the official statistics, in tabular and graphic form, for the reported occurrence of nationally notifiable infectious diseases and conditions in the United States for 2013. Unless otherwise noted, data are final totals for 2013 reported as of June 30, 2014. These statistics are collected and compiled from reports sent by U.S. state and territory, New York City, and District of Columbia health departments to the National Notifiable Diseases Surveillance System (NNDSS), which is operated by CDC in collaboration with the Council of State and Territorial Epidemiologists (CSTE). This summary is available at http://www.cdc.gov/mmwr/mmwr_nd/index.html. This site also includes summary publications from previous years.
Summary of Notifiable Infectious Diseases and Conditions - United States, 2014.
Adams, Deborah A; Thomas, Kimberly R; Jajosky, Ruth Ann; Foster, Loretta; Sharp, Pearl; Onweh, Diana H; Schley, Alan W; Anderson, Willie J
2016-10-14
The Summary of Notifiable Infectious Diseases and Conditions-United States, 2014 (hereafter referred to as the summary) contains the official statistics, in tabular and graphic form, for the reported occurrence of nationally notifiable infectious diseases and conditions in the United States for 2014. Unless otherwise noted, data are final totals for 2014 reported as of June 30, 2015. These statistics are collected and compiled from reports sent by U.S. state and territory, New York City, and District of Columbia health departments to the National Notifiable Diseases Surveillance System (NNDSS), which is operated by CDC in collaboration with the Council of State and Territorial Epidemiologists (CSTE). This summary is available at http://www.cdc.gov/mmwr/mmwr_nd/index.html. This site also includes summary publications from previous years.
NASA Technical Reports Server (NTRS)
1977-01-01
Captive-active tests consisted of three mated carrier aircraft/Orbiter flights with an active manned Orbiter. The objectives of this series of flights were to (1) verify the separation profile, (2) verify the integrated structure, aerodynamics, and flight control system, (3) verify Orbiter integrated system operations, and (4) refine and finalize carrier aircraft, Orbiter crew, and ground procedures in preparation for free flight tests. A summary description of the flights is presented with assessments of flight test requirements, and of the performance operations, and of significant flight anomalies is included.
Lightning Strike Peak Current Probabilities as Related to Space Shuttle Operations
NASA Technical Reports Server (NTRS)
Johnson, Dale L.; Vaughan, William W.
2000-01-01
A summary is presented of basic lightning characteristics/criteria applicable to current and future aerospace vehicles. The paper provides estimates on the probability of occurrence of a 200 kA peak lightning return current, should lightning strike an aerospace vehicle in various operational phases, i.e., roll-out, on-pad, launch, reenter/land, and return-to-launch site. A literature search was conducted for previous work concerning occurrence and measurement of peak lighting currents, modeling, and estimating the probabilities of launch vehicles/objects being struck by lightning. This paper presents a summary of these results.
Visualization of the significance of Receiver Operating Characteristics based on confidence ellipses
NASA Astrophysics Data System (ADS)
Sarlis, Nicholas V.; Christopoulos, Stavros-Richard G.
2014-03-01
The Receiver Operating Characteristics (ROC) is used for the evaluation of prediction methods in various disciplines like meteorology, geophysics, complex system physics, medicine etc. The estimation of the significance of a binary prediction method, however, remains a cumbersome task and is usually done by repeating the calculations by Monte Carlo. The FORTRAN code provided here simplifies this problem by evaluating the significance of binary predictions for a family of ellipses which are based on confidence ellipses and cover the whole ROC space. Catalogue identifier: AERY_v1_0 Program summary URL:http://cpc.cs.qub.ac.uk/summaries/AERY_v1_0.html Program obtainable from: CPC Program Library, Queen’s University, Belfast, N. Ireland Licensing provisions: Standard CPC licence, http://cpc.cs.qub.ac.uk/licence/licence.html No. of lines in distributed program, including test data, etc.: 11511 No. of bytes in distributed program, including test data, etc.: 72906 Distribution format: tar.gz Programming language: FORTRAN. Computer: Any computer supporting a GNU FORTRAN compiler. Operating system: Linux, MacOS, Windows. RAM: 1Mbyte Classification: 4.13, 9, 14. Nature of problem: The Receiver Operating Characteristics (ROC) is used for the evaluation of prediction methods in various disciplines like meteorology, geophysics, complex system physics, medicine etc. The estimation of the significance of a binary prediction method, however, remains a cumbersome task and is usually done by repeating the calculations by Monte Carlo. The FORTRAN code provided here simplifies this problem by evaluating the significance of binary predictions for a family of ellipses which are based on confidence ellipses and cover the whole ROC space. Solution method: Using the statistics of random binary predictions for a given value of the predictor threshold ɛt, one can construct the corresponding confidence ellipses. The envelope of these corresponding confidence ellipses is estimated when ɛt varies from 0 to 1. This way a new family of ellipses is obtained, named k-ellipses, which covers the whole ROC plane and leads to a well defined Area Under the Curve (AUC). For the latter quantity, Mason and Graham [1] have shown that it follows the Mann-Whitney U-statistics [2] which can be applied [3] for the estimation of the statistical significance of each k-ellipse. As the transformation is invertible, any point on the ROC plane corresponds to a unique value of k, thus to a unique p-value to obtain this point by chance. The present FORTRAN code provides this p-value field on the ROC plane as well as the k-ellipses corresponding to the (p=)10%, 5% and 1% significance levels using as input the number of the positive (P) and negative (Q) cases to be predicted. Unusual features: In some machines, the compiler directive -O2 or -O3 should be used to avoid NaN’s in some points of the p-field along the diagonal. Running time: Depending on the application, e.g., 4s for an Intel(R) Core(TM)2 CPU E7600 at 3.06 GHz with 2 GB RAM for the examples presented here References: [1] S.J. Mason, N.E. Graham, Quart. J. Roy. Meteor. Soc. 128 (2002) 2145. [2] H.B. Mann, D.R. Whitney, Ann. Math. Statist. 18 (1947) 50. [3] L.C. Dinneen, B.C. Blakesley, J. Roy. Stat. Soc. Ser. C Appl. Stat. 22 (1973) 269.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-23
... for OMB Review; Comment Request; Operations Under Water ACTION: Notice. SUMMARY: The Department of... collection request (ICR) titled, ``Operations Under Water,'' to the Office of Management and Budget (OMB) for review and approval for continued use, without change, in accordance with the Paperwork Reduction Act...
77 FR 8896 - Notice of Proposed Information Collection for 1029-0036
Federal Register 2010, 2011, 2012, 2013, 2014
2012-02-15
... request for Surface Mining Permit Applications--Minimum Requirements for Reclamation and Operation Plan... Permit Applications-- Minimum Requirements for Reclamation and Operation Plan. OSM is requesting a 3-year... Requirements for Reclamation and Operation Plan. OMB Control Number: 1029-0036. SUMMARY: Sections 507(b), 508(a...
75 FR 51938 - Drawbridge Operation Regulation; Taunton River, Fall River and Somerset, MA
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-24
... DEPARTMENT OF HOMELAND SECURITY Coast Guard 33 CFR Part 117 [Docket No. USCG-2010-0234] RIN 1625-AA09 Drawbridge Operation Regulation; Taunton River, Fall River and Somerset, MA AGENCY: Coast Guard, DHS. ACTION: Final rule. SUMMARY: The Coast Guard has changed the drawbridge operation regulations...
DOT National Transportation Integrated Search
2017-08-01
The rail industrys recent shift towards larger and heavier railcars has influenced Class III/short line railroad operation and track maintenance costs. Class III railroads earn less than $38.1 million in annual revenue and generally operate first ...
42 CFR 410.38 - Durable medical equipment: Scope and conditions.
Code of Federal Regulations, 2010 CFR
2010-10-01
... vehicle whose steering is operated by an electronic device or a joystick to control direction and turning) or a power-operated vehicle (a three or four-wheeled motorized scooter that is operated by a tiller..., physical examination, diagnostic tests, summary of findings, diagnoses, treatment plans and/or other...
42 CFR 410.38 - Durable medical equipment: Scope and conditions.
Code of Federal Regulations, 2011 CFR
2011-10-01
... vehicle whose steering is operated by an electronic device or a joystick to control direction and turning) or a power-operated vehicle (a three or four-wheeled motorized scooter that is operated by a tiller..., physical examination, diagnostic tests, summary of findings, diagnoses, treatment plans and/or other...
42 CFR 410.38 - Durable medical equipment: Scope and conditions.
Code of Federal Regulations, 2012 CFR
2012-10-01
... vehicle whose steering is operated by an electronic device or a joystick to control direction and turning) or a power-operated vehicle (a three or four-wheeled motorized scooter that is operated by a tiller..., physical examination, diagnostic tests, summary of findings, diagnoses, treatment plans and/or other...
78 FR 28278 - Operating Limitations at New York LaGuardia Airport
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-14
... between carriers under the same marketing control up to 5 business days after the actual operation. This... of Extension to Order. SUMMARY: This action amends the Order Limiting Operations at New York... Rule on Slot Management and Transparency for LaGuardia Airport, John F. Kennedy International Airport...
76 FR 18616 - Operating Limitations at New York LaGuardia Airport
Federal Register 2010, 2011, 2012, 2013, 2014
2011-04-04
... under the same marketing control up to 5 business days after the actual operation. This post-transfer... of Extension to Order. SUMMARY: This action amends the Order Limiting Operations at New York..., 2008, and October 7, 2009. The Order remains effective until the final Congestion Management Rule for...
77 FR 77001 - Comprehensive Review of Licensing and Operating Rules for Satellite Services
Federal Register 2010, 2011, 2012, 2013, 2014
2012-12-31
...] Comprehensive Review of Licensing and Operating Rules for Satellite Services AGENCY: Federal Communications... Notice of Proposed Rulemaking that initiated a comprehensive review of the Commission's rules governing... summary of the Order in IB Docket No. 12-267, Comprehensive Review of Licensing and Operating Rules for...
40 CFR 60.56a - Standards for municipal waste combustor operating practices.
Code of Federal Regulations, 2012 CFR
2012-07-01
... cause such facility to exceed the carbon monoxide standards shown in table 1. Table 1—MWC Operating..., at a minimum, address the following elements of MWC unit operation: (1) Summary of the applicable... periodic upset or off-specification conditions; (8) Procedures for minimizing particulate matter carryover...
40 CFR 60.56a - Standards for municipal waste combustor operating practices.
Code of Federal Regulations, 2013 CFR
2013-07-01
... cause such facility to exceed the carbon monoxide standards shown in table 1. Table 1—MWC Operating..., at a minimum, address the following elements of MWC unit operation: (1) Summary of the applicable... periodic upset or off-specification conditions; (8) Procedures for minimizing particulate matter carryover...
40 CFR 60.56a - Standards for municipal waste combustor operating practices.
Code of Federal Regulations, 2011 CFR
2011-07-01
... cause such facility to exceed the carbon monoxide standards shown in table 1. Table 1—MWC Operating..., at a minimum, address the following elements of MWC unit operation: (1) Summary of the applicable... periodic upset or off-specification conditions; (8) Procedures for minimizing particulate matter carryover...
40 CFR 60.56a - Standards for municipal waste combustor operating practices.
Code of Federal Regulations, 2014 CFR
2014-07-01
... cause such facility to exceed the carbon monoxide standards shown in table 1. Table 1—MWC Operating..., at a minimum, address the following elements of MWC unit operation: (1) Summary of the applicable... periodic upset or off-specification conditions; (8) Procedures for minimizing particulate matter carryover...
[12th Annual] Maintenance & Operations Cost Study.
ERIC Educational Resources Information Center
Deriso, Jerald L.; Lane, C. Jerome
1983-01-01
Comparisons are shown between budgeted maintenance and operations costs for 1982-83 and the preceding two years' actual costs. Also provided is a summary of a 10-year comparison of net current expenditures per student, compared with maintenance and operations costs per student. Data are presented for 10 geographical regions. (MLF)
13th Annual Maintenance & Operations Cost Study.
ERIC Educational Resources Information Center
Deriso, Jerald L.
1984-01-01
Comparisons are drawn between budgeted maintenance and operations costs for 1983-84 and the preceding 2 years' actual costs. Also provided is a summary of a 10-year comparison of net current expenditures per student, compared with maintenance and operations costs per student. Data are presented for 10 geographical regions. (MLF)
76 FR 63839 - Drawbridge Operation Regulations; Neuse River, New Bern, NC
Federal Register 2010, 2011, 2012, 2013, 2014
2011-10-14
... Operation Regulations; Neuse River, New Bern, NC AGENCY: Coast Guard, DHS. ACTION: Notice of temporary deviation from regulations. SUMMARY: The Commander, Fifth Coast Guard District, has issued a temporary deviation from the regulations governing the operation of the Neuse River Railroad Bridge, at mile 33.7...
76 FR 69632 - Drawbridge Operation Regulation; Neuse River, New Bern, NC
Federal Register 2010, 2011, 2012, 2013, 2014
2011-11-09
... Operation Regulation; Neuse River, New Bern, NC AGENCY: Coast Guard, DHS. ACTION: Notice of temporary deviation from regulations. SUMMARY: The Commander, Fifth Coast Guard District, has issued a temporary deviation from the regulations governing the operation of the Neuse River Railroad Bridge across the Neuse...
78 FR 26799 - Waterway Suitability Assessment for Expansion of Liquefied Gas Terminals; Beaumont, TX
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-08
... and request for comments. SUMMARY: In accordance with Coast Guard regulations, Martin Operating.... Martin Operating Partnership's Stanolind Cut Terminal in Beaumont, Texas submitted an LOI on January 25... refer to NVIC 01-2011 for process information and guidance in evaluating Martin Operating Partnership LP...
Ghajarzadeh, Mahsa; Mohammadifar, Mehdi; Azarkhish, Kamran; Emami-Razavi, Seyed Hassan
2014-01-01
We did this systematic review to determine diagnostic accuracy of sono-elastography in evaluating cervical lymph nodes (LNs). A highly sensitive search for sono-elastography and LNs was performed in MEDLINE, Cochrane Library, ACP Journal Club, EMBASE, Health Technology assessment, and ISI web of knowledge for studies published prior to December 2012. SPSS version 18 (SPSS Inc., Chicago, IL, USA) used for descriptive analysis and meta-disk version 1.4 applied for meta-analysis. Forest plots for pooled estimates and summery of receiver operating characteristic plots for different cut-offs were produced. The literature and manual search yielded 69 articles, of which 10 were eligible to include. A total of 578 individuals with a total number of 936 cervical LNs was evaluated (502 malignant and 434 benign). The summary sensitivity of the scoring and strain ratio (SR) measurements for the differentiation of benign and malignant LNs were 0.76 (95% CI: 0.71–0.8) and 0.83 (95% CI: 0.78–0.87). The summary specificities were 0.8 (95% confidence interval [CI]: 0.75–0.84) and 0.84 (95% CI: 0.79–0.88), respectively. Area under the curve for scoring system was 0.86 (standard error [SE] = 0.03) and 0.95 (SE = 0.02) for SR measurement. Sono-elastograohy has high accuracy in differentiating benign and malignant cervical LNs. PMID:25709787
Zhou, Q; Ye, Z J; Su, Y; Zhang, J C; Shi, H Z
2010-08-01
N-terminal pro-brain natriuretic peptide (NT-proBNP) is a biomarker useful in diagnosis of pleural effusion due to heart failure. Thus far, its overall diagnostic accuracy has not been systematically reviewed. The aim of the present meta-analysis was to establish the overall diagnostic accuracy of the measurement of pleural NT-proBNP for identifying pleural effusion due to heart failure. After a systematic review of English-language studies, sensitivity, specificity, and other measures of accuracy of NT-proBNP concentrations in pleural fluid in the diagnosis of pleural effusion resulting from heart failure were pooled using fixed-effects models. Summary receiver operating characteristic curves were used to summarise overall test performance. Eight publications met the inclusion criteria. The summary estimates for pleural NT-proBNP in the diagnosis of pleural effusion attributable to heart failure were: sensitivity 0.95 (95% CI 0.92 to 0.97), specificity 0.94 (0.92 to 0.96), positive likelihood ratio 14.12 (10.23 to 19.51), negative likelihood ratio 0.06 (0.04 to 0.09) and diagnostic OR 213.87 (122.50 to 373.40). NT-proBNP levels in pleural fluid showed a high diagnostic accuracy and may help accurately differentiate cardiac from non-cardiac conditions in patients presenting with pleural effusion.
Ghajarzadeh, Mahsa; Mohammadifar, Mehdi; Azarkhish, Kamran; Emami-Razavi, Seyed Hassan
2014-12-01
We did this systematic review to determine diagnostic accuracy of sono-elastography in evaluating cervical lymph nodes (LNs). A highly sensitive search for sono-elastography and LNs was performed in MEDLINE, Cochrane Library, ACP Journal Club, EMBASE, Health Technology assessment, and ISI web of knowledge for studies published prior to December 2012. SPSS version 18 (SPSS Inc., Chicago, IL, USA) used for descriptive analysis and meta-disk version 1.4 applied for meta-analysis. Forest plots for pooled estimates and summery of receiver operating characteristic plots for different cut-offs were produced. The literature and manual search yielded 69 articles, of which 10 were eligible to include. A total of 578 individuals with a total number of 936 cervical LNs was evaluated (502 malignant and 434 benign). The summary sensitivity of the scoring and strain ratio (SR) measurements for the differentiation of benign and malignant LNs were 0.76 (95% CI: 0.71-0.8) and 0.83 (95% CI: 0.78-0.87). The summary specificities were 0.8 (95% confidence interval [CI]: 0.75-0.84) and 0.84 (95% CI: 0.79-0.88), respectively. Area under the curve for scoring system was 0.86 (standard error [SE] = 0.03) and 0.95 (SE = 0.02) for SR measurement. Sono-elastograohy has high accuracy in differentiating benign and malignant cervical LNs.
Validation of reactive gases and aerosols in the MACC global analysis and forecast system
NASA Astrophysics Data System (ADS)
Eskes, H.; Huijnen, V.; Arola, A.; Benedictow, A.; Blechschmidt, A.-M.; Botek, E.; Boucher, O.; Bouarar, I.; Chabrillat, S.; Cuevas, E.; Engelen, R.; Flentje, H.; Gaudel, A.; Griesfeller, J.; Jones, L.; Kapsomenakis, J.; Katragkou, E.; Kinne, S.; Langerock, B.; Razinger, M.; Richter, A.; Schultz, M.; Schulz, M.; Sudarchikova, N.; Thouret, V.; Vrekoussis, M.; Wagner, A.; Zerefos, C.
2015-02-01
The European MACC (Monitoring Atmospheric Composition and Climate) project is preparing the operational Copernicus Atmosphere Monitoring Service (CAMS), one of the services of the European Copernicus Programme on Earth observation and environmental services. MACC uses data assimilation to combine in-situ and remote sensing observations with global and regional models of atmospheric reactive gases, aerosols and greenhouse gases, and is based on the Integrated Forecast System of the ECMWF. The global component of the MACC service has a dedicated validation activity to document the quality of the atmospheric composition products. In this paper we discuss the approach to validation that has been developed over the past three years. Topics discussed are the validation requirements, the operational aspects, the measurement data sets used, the structure of the validation reports, the models and assimilation systems validated, the procedure to introduce new upgrades, and the scoring methods. One specific target of the MACC system concerns forecasting special events with high pollution concentrations. Such events receive extra attention in the validation process. Finally, a summary is provided of the results from the validation of the latest set of daily global analysis and forecast products from the MACC system reported in November 2014.
Jackknife variance of the partial area under the empirical receiver operating characteristic curve.
Bandos, Andriy I; Guo, Ben; Gur, David
2017-04-01
Receiver operating characteristic analysis provides an important methodology for assessing traditional (e.g., imaging technologies and clinical practices) and new (e.g., genomic studies, biomarker development) diagnostic problems. The area under the clinically/practically relevant part of the receiver operating characteristic curve (partial area or partial area under the receiver operating characteristic curve) is an important performance index summarizing diagnostic accuracy at multiple operating points (decision thresholds) that are relevant to actual clinical practice. A robust estimate of the partial area under the receiver operating characteristic curve is provided by the area under the corresponding part of the empirical receiver operating characteristic curve. We derive a closed-form expression for the jackknife variance of the partial area under the empirical receiver operating characteristic curve. Using the derived analytical expression, we investigate the differences between the jackknife variance and a conventional variance estimator. The relative properties in finite samples are demonstrated in a simulation study. The developed formula enables an easy way to estimate the variance of the empirical partial area under the receiver operating characteristic curve, thereby substantially reducing the computation burden, and provides important insight into the structure of the variability. We demonstrate that when compared with the conventional approach, the jackknife variance has substantially smaller bias, and leads to a more appropriate type I error rate of the Wald-type test. The use of the jackknife variance is illustrated in the analysis of a data set from a diagnostic imaging study.
Vision for the Future of the US National Strong-Motion Program
,
1997-01-01
This document provides the requested vision for the future of the National Strong-Motion Program operated by the US Geological Survey. Options for operation of the program are presented in a companion document. Each of the three major charges of the EHRP, program council pertaining to the vision document is addressed here. The 'Vision Summary' through a series of answers to specific questions is intended to provide a complete synopsis of the committees response to program council charges. The Vision for the Future of the NSMP is presented as section III of the Summary. Analysis and detailed discussion supporting the answers in the summary are presented as sections organized according to the charges of the program council. The mission for the program is adopted from that developed at the national workshop entitled 'Research Needs for Strong Motion Data to Support Earthquake Engineering' sponsored by the National Science Foundation.
Plans for the extreme ultraviolet explorer data base
NASA Technical Reports Server (NTRS)
Marshall, Herman L.; Dobson, Carl A.; Malina, Roger F.; Bowyer, Stuart
1988-01-01
The paper presents an approach for storage and fast access to data that will be obtained by the Extreme Ultraviolet Explorer (EUVE), a satellite payload scheduled for launch in 1991. The EUVE telescopes will be operated remotely from the EUVE Science Operation Center (SOC) located at the University of California, Berkeley. The EUVE science payload consists of three scanning telescope carrying out an all-sky survey in the 80-800 A spectral region and a Deep Survey/Spectrometer telescope performing a deep survey in the 80-250 A spectral region. Guest Observers will remotely access the EUVE spectrometer database at the SOC. The EUVE database will consist of about 2 X 10 to the 10th bytes of information in a very compact form, very similar to the raw telemetry data. A history file will be built concurrently giving telescope parameters, command history, attitude summaries, engineering summaries, anomalous events, and ephemeris summaries.