40 CFR 61.133 - Standard: Light-oil sumps.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 9 2014-07-01 2014-07-01 false Standard: Light-oil sumps. 61.133... Emissions from Coke By-Product Recovery Plants § 61.133 Standard: Light-oil sumps. (a) Each owner or operator of a light-oil sump shall enclose and seal the liquid surface in the sump to form a closed system...
40 CFR 61.133 - Standard: Light-oil sumps.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 9 2013-07-01 2013-07-01 false Standard: Light-oil sumps. 61.133... Emissions from Coke By-Product Recovery Plants § 61.133 Standard: Light-oil sumps. (a) Each owner or operator of a light-oil sump shall enclose and seal the liquid surface in the sump to form a closed system...
40 CFR 61.133 - Standard: Light-oil sumps.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 9 2012-07-01 2012-07-01 false Standard: Light-oil sumps. 61.133... Emissions from Coke By-Product Recovery Plants § 61.133 Standard: Light-oil sumps. (a) Each owner or operator of a light-oil sump shall enclose and seal the liquid surface in the sump to form a closed system...
40 CFR 61.133 - Standard: Light-oil sumps.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 8 2011-07-01 2011-07-01 false Standard: Light-oil sumps. 61.133... Emissions from Coke By-Product Recovery Plants § 61.133 Standard: Light-oil sumps. (a) Each owner or operator of a light-oil sump shall enclose and seal the liquid surface in the sump to form a closed system...
Conceptual design report for the project to install leak detection in FAST-FT-534/548/549
DOE Office of Scientific and Technical Information (OSTI.GOV)
Galloway, K.J.
1992-07-01
This report provides conceptual designs and design recommendations for installing secondary containment and leak detection systems for three sumps at the Fluorinel and Storage Facility (FAST), CPP-666. The FAST facility is located at the Idaho Chemical Processing Plant (ICPP) at the Idaho National Engineering Laboratory (INEL). The three sumps receive various materials from the FAST water treatment process. This project involves sump upgrades to meet appropriate environmental requirements. The steps include: providing sump modifications or designs for the installation of leak chases and/or leakage accumulation, coating the sump concrete with a chemical resistant sealant (except for sump VES-FT-534 which ismore » already lined with stainless steel) to act as secondary containment, lining the sumps with a primary containment system, and providing a means to detect and remove primary containment leakage that may occur.« less
40 CFR Appendix A to Subpart T of... - Test of Solvent Cleaning Procedures
Code of Federal Regulations, 2011 CFR
2011-07-01
... condenser or the sump heater? A. Primary condenser B. Sump heater C. Turn both on at same time D. Either A or B is correct ___ 8. During shutdown, what must be turned off first, the primary condenser or the sump heater? A. Primary condenser B. Sump heater C. Turn both off at same time D. Either A or B is...
14 CFR 25.971 - Fuel tank sump.
Code of Federal Regulations, 2010 CFR
2010-01-01
... must have a sump with an effective capacity, in the normal ground attitude, of not less than the... with the airplane in the ground attitude. (c) Each fuel tank sump must have an accessible drain that...
14 CFR 29.971 - Fuel tank sump.
Code of Federal Regulations, 2010 CFR
2010-01-01
... effective with the rotorcraft in any normal attitude, and must be located so that the sump contents cannot... water from each part of the tank to the sump with the rotorcraft in any ground attitude to be expected...
SAFL Baffle retrofit for suspended sediment removal in storm sewer sumps.
Howard, Adam; Mohseni, Omid; Gulliver, John; Stefan, Heinz
2011-11-15
Standard sumps (manholes) provide a location for pipe junctions and maintenance access in stormwater drainage systems. Standard sumps can also remove sand and silt particles from stormwater, but have a high propensity for washout of the collected sediment. With appropriate maintenance these sumps may qualify as a stormwater best management practice (BMP) device for the removal of suspended sediment from stormwater runoff. To decrease the maintenance frequency and prevent standard sumps from becoming a source of suspended sediment under high flow conditions, a porous baffle, named the SAFL Baffle, has been designed and tested as a retrofit to the sump. Multiple configurations with varying percent open area and different angles of attack were evaluated in scale models. An optimum configuration was then constructed at the prototype scale and evaluated for both removal efficiency and washout. Results obtained with the retrofit indicate that with the right baffle dimensions and porosity, sediment washout from the sump at high flow rates can be almost eliminated, and removal efficiency can be significantly increased at low flow rates. Removal efficiency and washout functions have been developed for standard sumps retrofitted with the SAFL Baffle. The results of this research provide a new, versatile stormwater treatment device and implemented new washout and removal efficiency testing procedures that will improve research and development of stormwater treatment devices. Copyright © 2011 Elsevier Ltd. All rights reserved.
Numerical Study on the Improvement of Oil Return Structure in Aero-Engine Bearing Chambers
NASA Astrophysics Data System (ADS)
Jingyu, Zhao; Yaguo, Lyv; Zhenxia, Liu; Guozhe, Ren
2018-03-01
Numerical study has been carried out to improve the unreasonable oil film accumulation and oil return effect of the bearing chamber. Ramp sump and eccentricity sump offtake structures are designed and improved, and oil-gas two-phase flow calculation model based on CLSVOF (coupled level set and volume of fluid) method is proposed. Based on the grid-independent analysis and verifying the rationality of numerical data, oil-gas movement mechanism and oil return characteristics for different scavenge offtakes are calculated and analyzed. Results show that both the ramp sump and eccentricity sump offtake structures have favorable effects on improving the local oil distribution such as recirculation and stripping, etc. at low rotation speeds and alleviating the rapid decline of scavenge efficiency at high rotation speeds. Meanwhile, the air shear force is the main reason for the rapid decline of scavenge efficiency, while the design of oil return sump makes for the oil discharge from the scavenge offtake, and the deeper the sump depth is, the better.
14 CFR 27.971 - Fuel tank sump.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Fuel tank sump. 27.971 Section 27.971 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: NORMAL CATEGORY ROTORCRAFT Powerplant Fuel System § 27.971 Fuel tank sump. (a) Each fuel tank...
14 CFR 29.971 - Fuel tank sump.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Fuel tank sump. 29.971 Section 29.971 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Powerplant Fuel System § 29.971 Fuel tank sump. (a) Each fuel tank...
14 CFR 29.971 - Fuel tank sump.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Fuel tank sump. 29.971 Section 29.971 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Powerplant Fuel System § 29.971 Fuel tank sump. (a) Each fuel tank...
14 CFR 25.971 - Fuel tank sump.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Fuel tank sump. 25.971 Section 25.971 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Powerplant Fuel System § 25.971 Fuel tank sump. (a) Each fuel tank...
14 CFR 25.971 - Fuel tank sump.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Fuel tank sump. 25.971 Section 25.971 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Powerplant Fuel System § 25.971 Fuel tank sump. (a) Each fuel tank...
14 CFR 25.971 - Fuel tank sump.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Fuel tank sump. 25.971 Section 25.971 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Powerplant Fuel System § 25.971 Fuel tank sump. (a) Each fuel tank...
14 CFR 27.971 - Fuel tank sump.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Fuel tank sump. 27.971 Section 27.971 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: NORMAL CATEGORY ROTORCRAFT Powerplant Fuel System § 27.971 Fuel tank sump. (a) Each fuel tank...
14 CFR 27.971 - Fuel tank sump.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Fuel tank sump. 27.971 Section 27.971 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: NORMAL CATEGORY ROTORCRAFT Powerplant Fuel System § 27.971 Fuel tank sump. (a) Each fuel tank...
14 CFR 25.971 - Fuel tank sump.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Fuel tank sump. 25.971 Section 25.971 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Powerplant Fuel System § 25.971 Fuel tank sump. (a) Each fuel tank...
14 CFR 29.971 - Fuel tank sump.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Fuel tank sump. 29.971 Section 29.971 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Powerplant Fuel System § 29.971 Fuel tank sump. (a) Each fuel tank...
14 CFR 29.971 - Fuel tank sump.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Fuel tank sump. 29.971 Section 29.971 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Powerplant Fuel System § 29.971 Fuel tank sump. (a) Each fuel tank...
14 CFR 27.971 - Fuel tank sump.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Fuel tank sump. 27.971 Section 27.971 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: NORMAL CATEGORY ROTORCRAFT Powerplant Fuel System § 27.971 Fuel tank sump. (a) Each fuel tank...
DWPF DECON FRIT: SUMP AND SLURRY SOLIDS ANALYSIS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Crawford, C.; Peeler, D.; Click, D.
The Savannah River National Laboratory (SRNL) has been requested to perform analyses on samples of the Defense Waste Processing Facility (DWPF) decon frit slurry (i.e., supernate samples and sump solid samples). Four 1-L liquid slurry samples were provided to SRNL by Savannah River Remediation (SRR) from the 'front-end' decon activities. Additionally, two 1-L sump solids samples were provided to SRNL for compositional and physical analysis. In this report, the physical and chemical characterization results of the slurry solids and sump solids are reported. Crawford et al. (2010) provide the results of the supernate analysis. The results of the sump solidsmore » are reported on a mass basis given the samples were essentially dry upon receipt. The results of the slurry solids were converted to a volume basis given approximately 2.4 grams of slurry solids were obtained from the {approx}4 liters of liquid slurry sample. Although there were slight differences in the analytical results between the sump solids and slurry solids the following general summary statements can be made. Slight differences in the results are also captured for specific analysis. (1) Physical characterization - (a) SEM/EDS analysis suggested that the samples were enriched in Li and Si (B and Na not detectable using the current EDS system) which is consistent with two of the four principle oxides of Frit 418 (B{sub 2}O{sub 3}, Na{sub 2}O, Li{sub 2}O and SiO{sub 2}). (b) SEM/EDS analysis also identified impurities which were elementally consistent with stainless steel (i.e., Fe, Ni, Cr contamination). (c) XRD results indicated that the sump solids samples were amorphous which is consistent with XRD results expected for a Frit 418 based sample. (d) For the sump solids, SEM/EDS analysis indicated that the particle size of the sump solids were consistent with that of an as received Frit 418 sample from a current DWPF vendor. (e) For the slurry solids, SEM/EDS analysis indicated that the particle size range of the slurry solids was much broader than compared to the sump solids. More specifically, there were significantly more fines in the slurry solids as compared to the sump solids. (f) PSD results indicated that > 99% of both the sump and slurry solids were less than 350 microns. The PSD results also supported SEM/EDS analysis that there were significantly more fines in the slurry solids as compared to the sump solids. (2) Weight Percent Solids - Based on the measured supernate density and mass of insoluble solids (2.388 grams) filtered from the four liters of liquid slurry samples, the weight percent insoluble solids was estimated to be 0.060 wt%. This level of insoluble solids is higher than the ETP WAC limit of 100 mg/L, or 0.01 wt% which suggests a separation technology of some type would be required. (3) Chemical Analysis - (a) Elemental results from ICP-ES analysis indicated that the sump solids and slurry were very consistent with the nominal composition of Frit 418. There were other elements identified by ICP analysis which were either consistent with the presence of stainless steel (as identified by SEM/EDS analysis) or impurities that have been observed in 'as received' Frit 418 from the vendor. (b) IC anion analysis of the sump solids and slurry solids indicated all of the species were less than detection limits. (c) Radionuclide analysis of the sump solids also indicated that most of the analytes were either at or below the detection limits. (d) Organic analysis of the sump solids and slurry solids indicated all of the species were less than detection limits. It should be noted that the results of this study may not be representative of future decon frit solutions or sump/slurry solids samples. Therefore, future DWPF decisions regarding the possible disposal pathways for either the aqueous or solid portions of the Decon Frit system need to factor in the potential differences. More specifically, introduction of a different frit or changes to other DWPF flowsheet unit operations (e.g., different sludge batch or coupling with other process streams) may impact not only the results but also the conclusions regarding acceptability with respect to the ETF WAC limits or other alternative disposal options.« less
Corrosion in a STP Sump. (Subtitle: What Causes It and What Can Be Done About It?)
State regulators have noticed extensive corrosion in the sumps for the submersible turbine pump (STP) of an underground storage tanks storing gasoline and E85. Acetic acid produced by biodegradation of ethanol that found its way into the sump is one plausible explanation. Resea...
14 CFR 23.971 - Fuel tank sump.
Code of Federal Regulations, 2010 CFR
2010-01-01
... ground and flight attitudes, of 0.25 percent of the tank capacity, or 1/16 gallon, whichever is greater... to its sump with the airplane in the normal ground attitude. (c) Each reciprocating engine fuel... normal flight attitude, water will drain from all parts of the tank except the sump to the sediment bowl...
Liquid metal pump for nuclear reactors
Allen, H.G.; Maloney, J.R.
1975-10-01
A pump for use in pumping high temperature liquids at high pressures, particularly liquid metals used to cool nuclear reactors is described. It is of the type in which the rotor is submerged in a sump but is fed by an inlet duct which bypasses the sump. A chamber, kept full of fluid, surrounds the pump casing into which fluid is bled from the pump discharge and from which fluid is fed to the rotor bearings and hence to the sump. This equalizes pressure inside and outside the pump casing and reduces or eliminates the thermal shock to the bearings and sump tank.
Exploratory Hydrocarbon Drilling Impacts to Arctic Lake Ecosystems
Thienpont, Joshua R.; Kokelj, Steven V.; Korosi, Jennifer B.; Cheng, Elisa S.; Desjardins, Cyndy; Kimpe, Linda E.; Blais, Jules M.; Pisaric, Michael FJ.; Smol, John P.
2013-01-01
Recent attention regarding the impacts of oil and gas development and exploitation has focused on the unintentional release of hydrocarbons into the environment, whilst the potential negative effects of other possible avenues of environmental contamination are less well documented. In the hydrocarbon-rich and ecologically sensitive Mackenzie Delta region (NT, Canada), saline wastes associated with hydrocarbon exploration have typically been disposed of in drilling sumps (i.e., large pits excavated into the permafrost) that were believed to be a permanent containment solution. However, failure of permafrost as a waste containment medium may cause impacts to lakes in this sensitive environment. Here, we examine the effects of degrading drilling sumps on water quality by combining paleolimnological approaches with the analysis of an extensive present-day water chemistry dataset. This dataset includes lakes believed to have been impacted by saline drilling fluids leaching from drilling sumps, lakes with no visible disturbances, and lakes impacted by significant, naturally occurring permafrost thaw in the form of retrogressive thaw slumps. We show that lakes impacted by compromised drilling sumps have significantly elevated lakewater conductivity levels compared to control sites. Chloride levels are particularly elevated in sump-impacted lakes relative to all other lakes included in the survey. Paleolimnological analyses showed that invertebrate assemblages appear to have responded to the leaching of drilling wastes by a discernible increase in a taxon known to be tolerant of elevated conductivity coincident with the timing of sump construction. This suggests construction and abandonment techniques at, or soon after, sump establishment may result in impacts to downstream aquatic ecosystems. With hydrocarbon development in the north predicted to expand in the coming decades, the use of sumps must be examined in light of the threat of accelerated permafrost thaw, and the potential for these industrial wastes to impact sensitive Arctic ecosystems. PMID:24223170
Exploratory hydrocarbon drilling impacts to Arctic lake ecosystems.
Thienpont, Joshua R; Kokelj, Steven V; Korosi, Jennifer B; Cheng, Elisa S; Desjardins, Cyndy; Kimpe, Linda E; Blais, Jules M; Pisaric, Michael F J; Smol, John P
2013-01-01
Recent attention regarding the impacts of oil and gas development and exploitation has focused on the unintentional release of hydrocarbons into the environment, whilst the potential negative effects of other possible avenues of environmental contamination are less well documented. In the hydrocarbon-rich and ecologically sensitive Mackenzie Delta region (NT, Canada), saline wastes associated with hydrocarbon exploration have typically been disposed of in drilling sumps (i.e., large pits excavated into the permafrost) that were believed to be a permanent containment solution. However, failure of permafrost as a waste containment medium may cause impacts to lakes in this sensitive environment. Here, we examine the effects of degrading drilling sumps on water quality by combining paleolimnological approaches with the analysis of an extensive present-day water chemistry dataset. This dataset includes lakes believed to have been impacted by saline drilling fluids leaching from drilling sumps, lakes with no visible disturbances, and lakes impacted by significant, naturally occurring permafrost thaw in the form of retrogressive thaw slumps. We show that lakes impacted by compromised drilling sumps have significantly elevated lakewater conductivity levels compared to control sites. Chloride levels are particularly elevated in sump-impacted lakes relative to all other lakes included in the survey. Paleolimnological analyses showed that invertebrate assemblages appear to have responded to the leaching of drilling wastes by a discernible increase in a taxon known to be tolerant of elevated conductivity coincident with the timing of sump construction. This suggests construction and abandonment techniques at, or soon after, sump establishment may result in impacts to downstream aquatic ecosystems. With hydrocarbon development in the north predicted to expand in the coming decades, the use of sumps must be examined in light of the threat of accelerated permafrost thaw, and the potential for these industrial wastes to impact sensitive Arctic ecosystems.
McDonald, Douglas B.; Buchholz, Carol E.
1994-01-01
A shield for restricting molten corium from flowing into a water sump disposed in a floor of a containment vessel includes upper and lower walls which extend vertically upwardly and downwardly from the floor for laterally bounding the sump. The upper wall includes a plurality of laterally spaced apart flow channels extending horizontally therethrough, with each channel having a bottom disposed coextensively with the floor for channeling water therefrom into the sump. Each channel has a height and a length predeterminedly selected for allowing heat from the molten corium to dissipate through the upper and lower walls as it flows therethrough for solidifying the molten corium therein to prevent accumulation thereof in the sump.
Aircraft Engine Sump Fire Mitigation
NASA Technical Reports Server (NTRS)
Rosenlieb, J. W.
1973-01-01
An investigation was performed of the conditions in which fires can result and be controlled within the bearing sump simulating that of a gas turbine engine; Esso 4040 Turbo Oil, Mobil Jet 2, and Monsanto MCS-2931 lubricants were used. Control variables include the oil inlet temperature, bearing temperature, oil inlet and scavenge rates, hot air inlet temperature and flow rate, and internal sump baffling. In addition to attempting spontaneous combustion, an electric spark and a rub (friction) mechanism were employed to ignite fires. Spontaneous combustion was not obtained; however, fires were readily ignited with the electric spark while using each of the three test lubricants. Fires were also ignited using the rub mechanism with the only test lubricant evaluated, Esso 4040. Major parameters controlling ignitions were: Sump configuration; Bearing and oil temperatures, hot air temperature and flow and bearing speed. Rubbing between stationary parts and rotating parts (eg. labyrinth seal and mating rub strip) is a very potent fire source suggesting that observed accidental fires in gas turbine sumps may well arise from this cause.
Numerical simulation on geometrical parameters for closed sump
NASA Astrophysics Data System (ADS)
Wang, Y. X.; Cheng, L.; Xia, C. Z.; Zhou, J. R.; Yan, H. Q.; Jiang, H. Y.
2016-05-01
The closed sump is a typical inlet passage of middle and small pumping station. It has the characteristics of low channel height, small foundation excavation depth, simple structure, a single cross sectional shape changes, ease of construction and other features, so more and more attention and application has been paying on this closed sump in pumping station project. However the flowing pattern within the closed sump is complex, the design is not perfect in some respects, the structure size does not be optimized. Based on the background for renewal and transformation of a pumping station, according to the three-dimensional incompressible fluid Reynolds-averaged N-S equations, the RNG k-e model, the CFD technology. The study on the draught in closed sump might reduce the length of pump shaft to enhance the stability of the pump unit operation. The results reveal the effect of the change of the height of plate. The turbulence in back wall might cause vortex when the height is high. The height of plate had be recommended control in 0.65D-0.85D.The better parameter combination of geometry of closed sump had be given through comparing the results of the orthogonal test and the comprehensive test. The floor clearance should be control in 1.0D. (D is the diameter of flared pipe)
System for removing liquid waste from a tank
Meneely, Timothy K.; Sherbine, Catherine A.
1994-01-01
A tank especially suited for nuclear applications is disclosed. The tank comprises a tank shell for protectively surrounding the liquid contained therein; an inlet positioned on the tank for passing a liquid into the tank; a sump positioned in an interior portion of the tank for forming a reservoir of the liquid; a sloped incline for resting the tank thereon and for creating a natural flow of the liquid toward the sump; a pump disposed adjacent the tank for pumping the liquid; and a pipe attached to the pump and extending into the sump for passing the liquid therethrough. The pump pumps the liquid in the sump through the pipe and into the pump for discharging the liquid out of the tank.
System for removing liquid waste from a tank
Meneely, T.K.; Sherbine, C.A.
1994-04-26
A tank especially suited for nuclear applications is disclosed. The tank comprises a tank shell for protectively surrounding the liquid contained therein; an inlet positioned on the tank for passing a liquid into the tank; a sump positioned in an interior portion of the tank for forming a reservoir of the liquid; a sloped incline for resting the tank thereon and for creating a natural flow of the liquid toward the sump; a pump disposed adjacent the tank for pumping the liquid; and a pipe attached to the pump and extending into the sump for passing the liquid there through. The pump pumps the liquid in the sump through the pipe and into the pump for discharging the liquid out of the tank. 2 figures.
Frutos Vázquez, Borja; Olaya Adán, Manuel; Quindós Poncela, Luis Santiago; Sainz Fernandez, Carlos; Fuente Merino, Ismael
2011-04-01
The present paper discusses the results of an empirical study of four approaches to reducing indoor radon concentrations based on depressurization techniques in underground sumps. The experiments were conducted in prototype housing built in an area of Spain where the average radon concentration at a depth of 1 m is 250 kBq m(-3). Sump effectiveness was analysed in two locations: underneath the basement, which involved cutting openings into the foundation, ground storey and roof slabs, and outside the basement walls, which entailed digging a pit alongside the building exterior. The effectiveness of both sumps was likewise tested with passive and forced ventilation methods. The systems proved to be highly efficient, lowering radon levels by 91-99%, except in the solution involving passive ventilation and the outside sump, where radon levels were reduced by 53-55%. At wind speeds of over 8 m/s, however, passive ventilation across an outside sump lowered radon levels by 95% due to a Venturi effect induced drop in pressure. Copyright © 2011 Elsevier Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Kirsten, C. C. (Inventor)
1976-01-01
A solar powered pump particularly suited for intermittently delivering a stream of water is reported. The pump is characterized by a housing adapted to be seated in a source of water having a water discharge port disposed above the water line of the source, a sump including a valved inlet port through which water is introduced to the sump, disposed beneath the water line, a displacer supported for vertical reciprocation in said housing, an air passageway extended between the vertically spaced faces of the displacer, and a tipple disposed adjacent to the water discharge port adapted to be filled in response to a discharge of water from the housing. Air above a displacer is expanded in response to solar energy impinging on the housing and transferred into pressurizing relation with the sump for forcing water from the sump.
NASA Technical Reports Server (NTRS)
Nolt, Gary D.
1988-01-01
Pump removes liquid seepage from small, restricted area and against large pressure head. Developed for moving small amounts of water and oil from sump pit 85 ft (25.91 m) deep. Fits in space only 6 1/2 in. (16.5 cm) in diameter and 18 in. (45.7 cm) long. In discharge part of pumping cycle, air forces liquid out of pump chamber through pipe. During filling part of pumping cycle, water enters pump chamber from sump pit. Float in chamber next to pump chamber controls pressurization through timer and solenoid valve.
5. Station Unwatering Pumps and Sump Pump for Units 1 ...
5. Station Unwatering Pumps and Sump Pump for Units 1 and 2, view to the west. The unwatering pumps are the two larger items toward the right side of the photograph (one in foreground and one in background. The smaller item toward the left of the photograph is the sump pump. These pumps are used for draining water from the draft chest for maintenance. - Washington Water Power Clark Fork River Cabinet Gorge Hydroelectric Development, Powerhouse, North Bank of Clark Fork River at Cabinet Gorge, Cabinet, Bonner County, ID
14 CFR 27.971 - Fuel tank sump.
Code of Federal Regulations, 2010 CFR
2010-01-01
... must have a drainable sump with an effective capacity in any ground attitude to be expected in service... that in any ground attitude to be expected in service, water will drain from all parts of the tank to...
20. Station Unwatering Pumps and Sump Pump, view to the ...
20. Station Unwatering Pumps and Sump Pump, view to the north. The station unwatering pumps are the two large units in the center and right foreground of photograph and are marked with the numbers 1 and 2. The sump pump is the smaller unit in left foreground of photograph. These pumps are used for unwatering the draft chests for maintenance. Note the draft tube unwatering valve visible in background between the two unwatering pumps. - Washington Water Power Clark Fork River Noxon Rapids Hydroelectric Development, Powerhouse, South bank of Clark Fork River at Noxon Rapids, Noxon, Sanders County, MT
Analysis on pressure characteristics of pump turbine guide bearing rotating sump based on VOF model
NASA Astrophysics Data System (ADS)
Zhai, L. M.; Yao, Z.; Huang, Q. S.; Xiao, Y. X.; Wang, Z. W.
2013-12-01
With the technology of Computational Fluid Dynamics (CFD), this paper conducts a 3D numerical simulation for the oil and gas flow field in the Pump turbine guide bearing rotating sump. VOF model is adopted in this simulation. This study calculates distribution of the oil-air phase and characteristics of the pressure. The influence of sump rotating speed, oil level and oil viscosity on the pressure at the inlet of oil-immersion plate are discussed. The results demonstrate that the static pressure at the inlet is roughly proportional to oil level. Too low level may result in the separation between lubrication oil and supply hole on the oil-immersion plate, which then disables the oil supply. The static pressure at the inlet increases parabola as the sump rotating speed increases. To ensure the supply pressure, the unit is not suitable for long time operation under low rotating speed. The temperature-viscosity effect of the lubricant oil has little influence on the oil pressure at the supply hole. This paper provides a theoretical base for the safe design and operation of the pump turbine rotating sump, and offers the inlet boundary condition for the analysis of the oil film dynamic characteristics of the turbine guide bearing.
14 CFR 23.971 - Fuel tank sump.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Fuel tank sump. 23.971 Section 23.971 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Powerplant Fuel System § 23.971 Fuel...
14 CFR 23.971 - Fuel tank sump.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Fuel tank sump. 23.971 Section 23.971 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Powerplant Fuel System § 23.971 Fuel...
14 CFR 23.971 - Fuel tank sump.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Fuel tank sump. 23.971 Section 23.971 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Powerplant Fuel System § 23.971 Fuel...
14 CFR 23.971 - Fuel tank sump.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Fuel tank sump. 23.971 Section 23.971 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Powerplant Fuel System § 23.971 Fuel...
Relationship between Ethanol in Fuel and Corrosion in STP Sumps
Steve Pollock is a Compliance Inspector with the Petroleum Program in the Virginia Department of Environmental Quality. During his inspections of the STP sumps of underground storage tanks at gasoline service stations in Virginia, Mr. Pollock noticed odd corrosion reactions in so...
Code of Federal Regulations, 2010 CFR
2010-07-01
... includes hard-piping, all drains and junction boxes, together with their associated sewer lines and other junction boxes (e.g., manholes, sumps, and lift stations) conveying regulated-material. For the purpose of... segregated from all other individual drain systems. Junction box means a sump, manhole, or access point to a...
40 CFR 265.304 - Monitoring and inspection.
Code of Federal Regulations, 2011 CFR
2011-07-01
... for two consecutive months, the amount of liquids in the sumps must be recorded at least quarterly. If... sump until the liquid level again stays below the pump operating level for two consecutive months. (c... (CONTINUED) INTERIM STATUS STANDARDS FOR OWNERS AND OPERATORS OF HAZARDOUS WASTE TREATMENT, STORAGE, AND...
40 CFR 265.304 - Monitoring and inspection.
Code of Federal Regulations, 2012 CFR
2012-07-01
... for two consecutive months, the amount of liquids in the sumps must be recorded at least quarterly. If... sump until the liquid level again stays below the pump operating level for two consecutive months. (c... (CONTINUED) INTERIM STATUS STANDARDS FOR OWNERS AND OPERATORS OF HAZARDOUS WASTE TREATMENT, STORAGE, AND...
40 CFR 265.304 - Monitoring and inspection.
Code of Federal Regulations, 2010 CFR
2010-07-01
... for two consecutive months, the amount of liquids in the sumps must be recorded at least quarterly. If... sump until the liquid level again stays below the pump operating level for two consecutive months. (c... (CONTINUED) INTERIM STATUS STANDARDS FOR OWNERS AND OPERATORS OF HAZARDOUS WASTE TREATMENT, STORAGE, AND...
40 CFR 265.304 - Monitoring and inspection.
Code of Federal Regulations, 2014 CFR
2014-07-01
... for two consecutive months, the amount of liquids in the sumps must be recorded at least quarterly. If... sump until the liquid level again stays below the pump operating level for two consecutive months. (c... (CONTINUED) INTERIM STATUS STANDARDS FOR OWNERS AND OPERATORS OF HAZARDOUS WASTE TREATMENT, STORAGE, AND...
40 CFR 265.304 - Monitoring and inspection.
Code of Federal Regulations, 2013 CFR
2013-07-01
... for two consecutive months, the amount of liquids in the sumps must be recorded at least quarterly. If... sump until the liquid level again stays below the pump operating level for two consecutive months. (c... (CONTINUED) INTERIM STATUS STANDARDS FOR OWNERS AND OPERATORS OF HAZARDOUS WASTE TREATMENT, STORAGE, AND...
Smith, Kirk P.
2011-01-01
Stormwater mobilizes litter and other debris along the roadway where it is transported to the highway drainage systems. Initial treatment for stormwater runoff typically is provided by catch basins in highway settings. Modification of catch basins to include hoods that cover the catch-basin outlet is intended to enhance catch-basin performance by retaining floatable debris and various hydrophobic organic compounds that tend to float on the water surface within the sump of the catch basin. The effectiveness of six deep-sump off-line catch basins equipped with hoods in reducing the mass of gross solids greater than 0.25 inches in diameter and concentrations of oil and grease (OG) and total petroleum hydrocarbons (TPH) was examined along the Southeast Expressway, in Boston, Massachusetts. Two deep-sump catch basins were equipped with cast-iron hoods. Three were equipped with molded plastic hoods, known as an Eliminator, and a single catch basin was equipped with a fiberglass anti-siphoning hood, known as a Snout. Samples of gross solids greater than 0.25 inches in diameter, excluding gravel and metallic materials, were routinely collected for a 6-month period from a collection structure mounted at the end of each catch-basin outlet pipe. After about 6 months, all floatable, saturated low-density and high-density solids were removed from each catch basin. In addition to the collection of samples of gross solids, samples of sump water from five catch basins and flow-weighted composite samples of stormwater from the outlet of one catch basin were collected and analyzed for concentrations of OG and TPH. A mass balance approach was used to assess the effectiveness of each catch basin equipped with a hood in retaining gross solids. The effectiveness of the deep-sump catch basins fitted with one of three types of hoods in retaining gross solids ranged from 27 to 52 percent. From 45 to 90 percent of the gross solids collected from the catch-basin sumps were composed of materials made of high-density plastics that did not float in water, and as a result, the effect that the catch-basin hoods had on these materials likely was marginal. The effectiveness for the deep-sump hooded catch basins, excluding the mass of high-density materials identified in the solids collected from the outlet pipe and the sump of the catch basins, ranged from 13 to 38 percent. The effectiveness for each catch basin, based solely on the material that remained floating at the end of the monitoring period, was less than 11 percent; however, these values likely underestimate the effectiveness of the hooded catch basins because much of the low-density material collected from the sumps may have been retained as floatable material before it was saturated and settled during non-storm conditions. The effectiveness of the catch basins equipped with hoods in reducing gross solids was not greatly different among the three types of hoods tested in this study. Concentrations of OG and TPH collected from the water surface of the catch-basins varied from catch basin to catch basin and were similar to concentrations of flow-weighted composite samples collected during storms. Comparisons indicate concentrations of OG and TPH in flow-weighted composite samples collected at the outlet of a catch basin equipped with an Eliminator hood were not substantially different from concentrations of the respective constituents in flow-weighted composite samples collected during a previous study from catch basins containing cast-iron hoods in the same study area. The similarity between these flow-weighted concentrations and the concentrations of the respective constituents in a vertical profile sample collected from the catch-basin sump indicates that OG and TPH are emulsified in the sump of each catch basin during storms and circumvent the hoods.
Aircraft engine sump-fire studies
NASA Technical Reports Server (NTRS)
Loomis, W. R.
1976-01-01
Results of ongoing experimental studies are reported in which a 125-millimeter-diameter-advanced-bearing test rig simulating an engine sump is being used to find the critical range of conditions for fires to occur. Design, material, and operating concepts and techniques are being studied with the objective of minimizing the problem. It has been found that the vapor temperature near a spark ignitor is most important in determining ignition potential. At temperatures producing oil vapor pressures below or much above the calculated flammability limits, fires have not been ignited. But fires have been routinely started within the theoretical flammability range. This indicates that generalizing the sump-fire problem may make it amenable to analysis, with the potential for realistic solutions.
Staged depressurization system
Schulz, T.L.
1993-11-02
A nuclear reactor having a reactor vessel disposed in a containment shell is depressurized in stages using depressurizer valves coupled in fluid communication with the coolant circuit. At least one sparger submerged in the in-containment refueling water storage tank which can be drained into the containment sump communicates between one or more of the valves and an inside of the containment shell. The depressurizer valves are opened in stages, preferably at progressively lower coolant levels and for opening progressively larger flowpaths to effect depressurization through a number of the valves in parallel. The valves can be associated with a pressurizer tank in the containment shell, coupled to a coolant outlet of the reactor. At least one depressurization valve stage openable at a lowest pressure is coupled directly between the coolant circuit and the containment shell. The reactor is disposed in the open sump in the containment shell, and a further valve couples the open sump to a conduit coupling the refueling water storage tank to the coolant circuit for adding water to the coolant circuit, whereby water in the containment shell can be added to the reactor from the open sump. 4 figures.
Staged depressurization system
Schulz, Terry L.
1993-01-01
A nuclear reactor having a reactor vessel disposed in a containment shell is depressurized in stages using depressurizer valves coupled in fluid communication with the coolant circuit. At least one sparger submerged in the in-containment refueling water storage tank which can be drained into the containment sump communicates between one or more of the valves and an inside of the containment shell. The depressurizer valves are opened in stages, preferably at progressively lower coolant levels and for opening progressively larger flowpaths to effect depressurization through a number of the valves in parallel. The valves can be associated with a pressurizer tank in the containment shell, coupled to a coolant outlet of the reactor. At least one depressurization valve stage openable at a lowest pressure is coupled directly between the coolant circuit and the containment shell. The reactor is disposed in the open sump in the containment shell, and a further valve couples the open sump to a conduit coupling the refueling water storage tank to the coolant circuit for adding water to the coolant circuit, whereby water in the containment shell can be added to the reactor from the open sump.
40 CFR 61.133 - Standard: Light-oil sumps.
Code of Federal Regulations, 2010 CFR
2010-07-01
... maintain a vent on the light-oil sump cover. Each vent pipe must be equipped with a water leg seal, a... more than 500 ppm above a background concentration, as measured by Method 21, a leak is detected. (2) If visible defects such as gaps in sealing materials are observed during a visual inspection, a leak...
40 CFR Appendix A to Subpart T of... - Test of Solvent Cleaning Procedures
Code of Federal Regulations, 2010 CFR
2010-07-01
...) AIR PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS FOR SOURCE.... Measure the time it takes the parts to travel a measured distance. ___ 3. Identify the sources of air... condenser or the sump heater? A. Primary condenser B. Sump heater C. Turn both on at same time D. Either A...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Knebel, J.U.; Kuhn, D.; Mueller, U.
1997-12-01
This article presents the basic physical phenomena and scaling criteria of passive decay heat removal from a large coolant pool by single-phase and two-phase natural circulation. The physical significance of the dimensionless similarity groups derived is evaluated. The above results are applied to the SUCO program that is performed at the Forschungszentrum Karlsruhe. The SUCO program is a three-step series of scaled model experiments investigating the possibility of a sump cooling concept for future light water reactors. The sump cooling concept is based on passive safety features within the containment. The work is supported by the German utilities and themore » Siemens AG. The article gives results of temperature and velocity measurements in the 1:20 linearly scaled SUCOS-2D test facility. The experiments are backed up by numerical calculations using the commercial software package Fluent. Finally, using the similarity analysis from above, the experimental results of the model geometry are scaled-up to the conditions in the prototype, allowing a first statement with regard to the feasibility of the sump cooling concept. 11 refs., 9 figs., 3 tabs.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Williams, Greg D.; Pearson, Walter H.; Evans, Nathan R.
2004-01-15
The Portland District of the U.S. Army Corps of Engineers is investigating plans to provide sediment to nourish beaches north of the Mouth of the Columbia River (MCR). Under the currently designed proposal, sediment dredged from the MCR will be temporarily stored at one of three proposed areas south of the North Jetty before being redredged and moved by a cutterhead pipeline dredge over the jetty to nourish Benson Beach. Resulting potential impacts to resident Dungeness crab (Cancer magister) and fishes represent one of the criteria for evaluating each of the alternative locations. To establish the species composition and relativemore » abundance of crabs and fishes associated with each of the three proposed sump areas, researchers from the Pacific Northwest National Laboratory Marine Sciences Division completed nine field sampling trips from July 8, 2003, to November 1, 2003, for a total of 113 successful trawls comprising an area of over 7.4 ha (74,156 m2). This report documents the results of that effort. To understand the relative risk of losses to crab populations associated with dredging impacts at the sump alternative areas, it is recommended that a modified dredge impact model be developed using the data collected in this study. This model should estimate crab adult equivalent loss and associated error rates to gain a population-level perspective on the potential entrainment impacts at each of the three alternative sump areas. As well, a sustained survey of Dungeness crab distribution and movement within the Columbia River estuary would clarify the relative value of the sump areas as a migratory corridor for crab populations, and support management decisions relative to issues associated with dredged material handling and disposal.« less
Statistical modelling of Fat, Oil and Grease (FOG) deposits in wastewater pump sumps.
Nieuwenhuis, Eva; Post, Johan; Duinmeijer, Alex; Langeveld, Jeroen; Clemens, François
2018-05-15
The accumulation of FOG (Fat, Oil and Grease) deposits in sewer pumping stations results in an increase in maintenance costs, malfunctioning of pumps and, a potential increase of wastewater spills in receiving open water bodies. It is thought that a variety of parameters (e.g. geometry of the pump sump, pump operation, socioeconomic parameters of the catchment) influences the built-up of FOG. Based on a database containing data of 126 pumping stations located in five Dutch municipalities a statistical model was built. It is shown that 3 parameters are most significant in explaining the occurrence of FOG deposits: mean income of the population in a catchment, the amount of energy (kinetic and potential) per m 3 per day and the density of restaurants, bars and hotels in a catchment. Further it is shown that there are significant differences between municipalities that can be traced back to the local 'design paradigm'. For example, in Amsterdam, the design philosophy of discharging in the pump sump under the water surface (and hence maintaining a low level of turbulence in the pump sump) results in an increase of the probability of the formation of FOG. Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.
Aircraft Engine Sump Fire Mitigation, Phase 2
NASA Technical Reports Server (NTRS)
Rosenlieb, J. W.
1978-01-01
The effect of changes in the input parameters (air leakage flow rate and temperature and lubricating oil inlet flow rate and temperature) over a specified range on the flammability conditions within an aircraft engine bearing sump was investigated. An analytical study was performed to determine the effect of various parameters on the generation rate of oil vapor from oil droplets in a hot air stream flowing in a cylindrical tube. The ignition of the vapor-air mixture by an ignition source was considered. The experimental investigation demonstrated that fires would be ignited by a spark ignitor over the full range of air and oil flow rates and air temperatures evaluated. However, no fires could be ignited when the oil inlet temperature was maintained below 41.7 K (290 F). The severity of the fires ignited were found to be directly proportional to the hot air flow rate. Reasonably good correlation was found between the mixture temperature in the sump at the ignitor location and the flammability limits as defined by flammability theory; thus a fairly reliable experimental method of determining flammable conditions within a sump was demonstrated. The computerized mathematical model shows that oil droplet size and air temperature have the greatest influence on the generation rate of oil vapor.
PROCESS WATER BUILDING, TRA605. FLOOR PLAN AND SECTION OF FLASH ...
PROCESS WATER BUILDING, TRA-605. FLOOR PLAN AND SECTION OF FLASH EVAPORATOR ROOM SHOWING ITS LOCATION ABOVE THE SEAL AND SUMP TANKS. PIPING TAKES WATER FROM SEAL TANK UPWARD TO FLASH EVAPORATORS AND THEN BACK DOWN TO SUMP TANK. BLAW-KNOX 3150-5-6, 8/1950. INL INDEX NO. 531-605-00-098-100011, REV. 3. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
Inclusion behaviour in the liquid core during continuous casting
NASA Astrophysics Data System (ADS)
Jiang, Guang S.
Water models using perspex have been built to study the fluid flow and recirculation patterns developed in the sump of a steel continuous casting machine and the influences these have on the behaviour of inclusions. An experimental method has been devised to simulate the behaviour of inclusions in the sump and to study the apportionment of the input flux of inclusions between the molten mould powder layer and the strand. The method entails the uses of finely dispersed coloured paraffin oil in the inlet stream together with a floating colourless paraffin layer on the top of the water in the model mould to simulate the molten powder layer on top of the molten steel.A theoretical model has been formulated which relates the inclusion separation in the sump to the fluid flow there. The inclusion removal ratio in the sump for a given continuous casting machine can be predicted using this theoretical model. The model, using the properties of liquid steel and practicable casting speeds, demonstrates that the removal of inclusions of small size (<40 um) from the mould sump is less than 5% efficient.Inclusion agglomeration plays an important role in inclusion removal. It has been shown that deep submersion of the SEN enhances the agglomeration of inclusion particle. Under certain conditions, for example, the average particle diameter in the meniscus region has been found to be as much as three times its value at the SEN nozzle.The use of fine alumina flakes or small air bubbles, together with a plane light source, has been found to be very successful in studying the fluid flow patterns developed in three-dimensional models. Employing this method, the fluid flow patterns developed on different planes within the model mould have been viewed and recorded photographically. The photographs so obtained have helped to explain the results obtained for the removal of inclusions. The fluid flow patterns developed when small outside diameter nozzles with deep SEN submerged depths are used have been found to be of benefit to the removal of inclusions.Increasing the SEN submerged depth promotes inclusion agglomeration and hence increases the inclusion removal ratio. Reducing the nozzle outside diameter and the casting speed increases the inclusion removal ratio in the sump. But the infleunces of these latter changes are not very strong, so that inclusion removal consideration need not influence the design strategies used for the casting speed and nozzle outside diameter. The SEN port angle has a little effect on the inclusion removal when using deep SEN submerged depth.Although argon stream introduced into the tundish nozzle stream can protect the nozzle blockage, it is not beneficial to the inclusion removal in the sump.
LOFT. Containment and service building (TAN650). Section through north/south axis. ...
LOFT. Containment and service building (TAN-650). Section through north/south axis. Shows basement and four additional levels of pre-amp tower, shielded roadway, chambers below reactor floor, railroad door, sumps, shielding. Section C shows basement sumps and chambers below reactor floor. Kaiser engineers 6413-11-STEP/LOFT-650-A-5. Date: October 1964. INEEL index code no. 036-650-00-486-122217 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
Credit PSR. View looks north northeast (20°) at the concrete ...
Credit PSR. View looks north northeast (20°) at the concrete pad which forms the top of the sump pump facility. In the background stand Building 4303 (Air Compressor Building), Building 4307 (Supply and Equipment Warehouse) at left, Building 4305 (Unicon Portable Hangar) at center, and Building 4306 (Boiler House) at right. Sign marking Building 4302 was made from a disused road sign from somewhere on Edwards AFB - Edwards Air Force Base, North Base, Sump Pump, East of Second Street, Boron, Kern County, CA
Pump station for radioactive waste water
Whitton, John P.; Klos, Dean M.; Carrara, Danny T.; Minno, John J.
2003-11-18
A pump station for transferring radioactive particle containing waste water, includes: (a.) an enclosed sump having a vertically elongated right frusto conical wall surface and a bottom surface and (b.) a submersible volute centrifugal pump having a horizontally rotating impeller and a volute exterior surface. The sump interior surface, the bottom surface and the volute exterior surface are made of stainless steel having a 30 Ra or finer surface finish. A 15 Ra finish has been found to be most cost effective. The pump station is used for transferring waste water, without accumulation of radioactive fines.
Development of high temperature liquid lubricants for low-heat rejection: Heavy duty diesel engines
NASA Technical Reports Server (NTRS)
Wiczynski, P. D.; Marolewski, T. A.
1993-01-01
The objective of this DOE program was to develop a liquid lubricant that will allow advanced diesel engines to operate at top ring reversal temperatures approaching 500 C and sump temperatures approaching 250 C. The lubricants developed demonstrated at marginal increase in sump temperature capability, approximately 15 C, and an increase in top ring reversal temperature. A 15W-40 synthetic lubricant designated HTL-4 was the best lubricant developed in terms of stability, wear control, deposit control dispersancy, and particulate emissions.
Seal Joint Analysis and Design for the Ares-I Upper Stage LOX Tank
NASA Technical Reports Server (NTRS)
Phillips, Dawn R.; Wingate, Robert J.
2011-01-01
The sealing capability of the Ares-I Upper Stage liquid oxygen tank-to-sump joint is assessed by analyzing the deflections of the joint components. Analyses are performed using three-dimensional symmetric wedge finite element models and the ABAQUS commercial finite element software. For the pressure loads and feedline interface loads, the analyses employ a mixed factor of safety approach to comply with the Constellation Program factor of safety requirements. Naflex pressure-assisted seals are considered first because they have been used successfully in similar seal joints in the Space Shuttle External Tank. For the baseline sump seal joint configuration with a Naflex seal, the predicted joint opening greatly exceeds the seal design specification. Three redesign options of the joint that maintain the use of a Naflex seal are studied. The joint openings for the redesigned seal joints show improvement over the baseline configuration; however, these joint openings still exceed the seal design specification. RACO pressure-assisted seals are considered next because they are known to also be used on the Space Shuttle External Tank, and the joint opening allowable is much larger than the specification for the Naflex seals. The finite element models for the RACO seal analyses are created by modifying the models that were used for the Naflex seal analyses. The analyses show that the RACO seal may provide sufficient sealing capability for the sump seal joint. The results provide reasonable data to recommend the design change and plan a testing program to determine the capability of RACO seals in the Ares-I Upper Stage liquid oxygen tank sump seal joint.
ASSESSMENT OF RELEASE RATES FOR RADIONUCLIDES IN ACTIVATED CONCRETE.
DOE Office of Scientific and Technical Information (OSTI.GOV)
SULLIVAN,T.M.
2003-08-23
The Maine Yankee (MY) nuclear power plant is undergoing the process of decontamination and decommissioning (D&D). Part of the process requires analyses that demonstrate that any radioactivity that remains after D&D will not cause exposure to radioactive contaminants to exceed acceptable limits. This requires knowledge of the distribution of radionuclides in the remaining material and their potential release mechanisms from the material to the contacting groundwater. In this study the concern involves radionuclide contamination in activated concrete in the ICI Sump below the containment building. Figures 1-3 are schematic representations of the ICI Sump. Figure 2 and 3 contain themore » relevant dimensions needed for the analysis. The key features of Figures 2 and 3 are the 3/8-inch carbon steel liner that isolates the activated concrete from the pit and the concrete wall, which is between 7 feet and 7 feet 2 inches thick. During operations, a small neutron flux from the reactor activated the carbon steel liner and the concrete outside the liner. Current MY plans call for filling the ICI sump with compacted sand.« less
Pump tank divider plate for sump suction sodium pumps
George, John A.; Nixon, Donald R.
1977-01-01
A circular plate extends across the diameter of "sump suction" pump, with a close clearance between the edge of the plate and the wall of the pump tank. The plate is located above the pump impeller, inlet and outlet flow nozzles but below the sodium free surface and effectively divides the pump tank into two separate chambers. On change of pump speed, the close fitting flow restriction plate limits the rate of flow into or out of the upper chamber, thereby minimizing the rate of level change in the tank and permitting time for the pump cover gas pressure to be varied to maintain an essentially constant level.
NASA Astrophysics Data System (ADS)
Samsudin, M. L.; Munisamy, K. M.; Thangaraju, S. K.
2015-09-01
Cooling water system is one of the essential auxiliary systems for a power generating plant. The decision to have an offshore pumping station, instead of onshore station, may have been driven by the scarcity in land area or for direct water supply access. However, the design has several disadvantages such as tendency for sediment intakes, limited condition monitoring activities and inaccessible sump for maintenance and modification. The paper reviews and lists several potential operational challenges and difficulties experienced with the offshore station. The influences of changing conditions such as varying seawater tide level, clogged intake screen, intake sedimentation issues and marine fouling on the sump walls and structures, are discussed and mitigating solutions are identified. While it is impractical to conduct physical model test for studying flow pattern, the CFD method can be an attractive assessment tools. In addition to this, a review of plant operating parameters can assist in identifying flow anomalies to anticipate potential deterioration. Finally the difficulty in incorporating the solutions to vortex and sediment problems within the sump is highlighted with preference for those which can be managed by limited access or those which are moveable with the vertical pump.
Shendell, Derek G; Carr, Michael
2013-10-01
Concentrations of radon in homes are thought to be dependent on several factors, including the presence of certain physical conditions of the house that act as entry points for this colorless, odorless gas. Drains and sump pits are currently sealed as part of radon mitigation, but doing so may cause drainage problems and mold. The authors attempted to determine if specific attributes and physical conditions of homes are associated with measured residential concentrations of radon. Radon tests were conducted in 96 participating homes in rural Hillsborough Township, New Jersey, November 2010-February 2011. Samplers were placed and a walk-through survey was conducted. Test devices were analyzed by a New Jersey certified radon testing laboratory and results compared to survey data. Overall, 50% of houses with a perimeter drain and 30% of houses with a sump pit exceeded the New Jersey and federal radon action level of 4.0 picocuries per liter, and 47% of homes with both a sump and a perimeter "French" drain exceeded this action level. The authors' results suggested certain physical conditions act as pathways allowing radon entry into homes. Results could be used by local and state agencies to start local initiatives, e.g., increased testing or to seal these components as partial mitigation.
Oil cooled, hermetic refrigerant compressor
English, William A.; Young, Robert R.
1985-01-01
A hermetic refrigerant compressor having an electric motor and compressor assembly in a hermetic shell is cooled by oil which is first cooled in an external cooler 18 and is then delivered through the shell to the top of the motor rotor 24 where most of it is flung radially outwardly within the confined space provided by the cap 50 which channels the flow of most of the oil around the top of the stator 26 and then out to a multiplicity of holes 52 to flow down to the sump and provide further cooling of the motor and compressor. Part of the oil descends internally of the motor to the annular chamber 58 to provide oil cooling of the lower part of the motor, with this oil exiting through vent hole 62 also to the sump. Suction gas with entrained oil and liquid refrigerant therein is delivered to an oil separator 68 from which the suction gas passes by a confined path in pipe 66 to the suction plenum 64 and the separated oil drops from the separator to the sump. By providing the oil cooling of the parts, the suction gas is not used for cooling purposes and accordingly increase in superheat is substantially avoided in the passage of the suction gas through the shell to the suction plenum 64.
Oil cooled, hermetic refrigerant compressor
English, W.A.; Young, R.R.
1985-05-14
A hermetic refrigerant compressor having an electric motor and compressor assembly in a hermetic shell is cooled by oil which is first cooled in an external cooler and is then delivered through the shell to the top of the motor rotor where most of it is flung radially outwardly within the confined space provided by the cap which channels the flow of most of the oil around the top of the stator and then out to a multiplicity of holes to flow down to the sump and provide further cooling of the motor and compressor. Part of the oil descends internally of the motor to the annular chamber to provide oil cooling of the lower part of the motor, with this oil exiting through vent hole also to the sump. Suction gas with entrained oil and liquid refrigerant therein is delivered to an oil separator from which the suction gas passes by a confined path in pipe to the suction plenum and the separated oil drops from the separator to the sump. By providing the oil cooling of the parts, the suction gas is not used for cooling purposes and accordingly increase in superheat is substantially avoided in the passage of the suction gas through the shell to the suction plenum. 3 figs.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sarkar, C.K.; Pandit, D.R.; Kwon, S.G.
The paper describes the hydraulic design and hydraulic transient analysis of the re-circulating water cooling system of the combined cyclo Sipco power cogeneration plant in Thailand. The power plant of 450 MW total capacity is proposed to be built in two stages. Stage one will produce 300 MW of power and will consist of two gas turbine generators (GTG) and one steam turbine generator (STG). Stage two will produce 150 MW of power and will consist of one GTG and one STG. The cooling system will consist of one GTG and one STG. The cooling system will consist of coolingmore » towers, a combined collecting basin and pump intake sump, pumps and motors, and separate conveyance systems and condensers for the generator units in the two stages. In a re-circulating water cooling system, cold water is pumped from the pump intake sump to the condensers through the conveyance system and hot water from the condensers is carried through the returning pipeline system to the cooling towers, whence the water after cooling is drained into the sump at the base of the towers. Total cooling water requirement for the system in stage one is estimated to be 112,000 gallons per minute (GPM), and that in stage two, 56,000 GPM. The sump is designed using the computer program HEC-2, developed by the US Army Corps of Engineers (COE) and the pump intake basin, following the recommendations of the Hydraulic Institute. The pumps were sized by computing the head loss in the system, and, the steady state and transient performances (during pump start-up and shut-down procedures and due to possible power or mechanical failure of one or all pumps) of the system were analyzed by mathematically modeling the system using the computer program WHAMO (Water Hammer nd Mass Oscillations), also developed by the COE.« less
Experimental study of hydraulics and sediment capture efficiency in catchbasins.
Tang, Yangbo; Zhu, David Z; Rajaratnam, N; van Duin, Bert
2016-12-01
Catchbasins (also known as gully pot in the UK and Australia) are used to receive surface runoff and drain the stormwater into storm sewers. The recent interest in catchbasins is to improve their effectiveness in removing sediments in stormwater. An experimental study was conducted to examine the hydraulic features and sediment capture efficiency in catchbasins, with and without a bottom sump. A sump basin is found to increase the sediment capture efficiency significantly. The effect of inlet control devices, which are commonly used to control the amount of flow into the downstream storm sewer system, is also studied. These devices will increase the water depth in the catchbasin and increase the sediment capture efficiency. Equations are developed for predicting the sediment capture efficiency in catchbasins.
Disposable sludge dewatering container and method
Cole, Clifford M.
1993-01-01
A device and method for preparing sludge for disposal comprising a box with a thin layer of gravel on the bottom and a thin layer of sand on the gravel layer, an array of perforated piping deployed throughout the gravel layer, and a sump in the gravel layer below the perforated piping array. Standpipes connect the array and sump to an external ion exchanger/fine particulate filter and a pump. Sludge is deposited on the sand layer and dewatered using a pump connected to the piping array, topping up with more sludge as the aqueous component of the sludge is extracted. When the box is full and the free standing water content of the sludge is acceptable, the standpipes are cut and sealed and the lid secured to the box.
30 CFR 817.45 - Hydrologic balance: Sediment control measures.
Code of Federal Regulations, 2012 CFR
2012-07-01
... control measures shall be designed, constructed, and maintained using the best technology currently... (8) Treating mine drainage in underground sumps. [44 FR 15422, Mar. 13, 1979, as amended at 48 FR...
30 CFR 817.45 - Hydrologic balance: Sediment control measures.
Code of Federal Regulations, 2013 CFR
2013-07-01
... control measures shall be designed, constructed, and maintained using the best technology currently... (8) Treating mine drainage in underground sumps. [44 FR 15422, Mar. 13, 1979, as amended at 48 FR...
30 CFR 817.45 - Hydrologic balance: Sediment control measures.
Code of Federal Regulations, 2014 CFR
2014-07-01
... control measures shall be designed, constructed, and maintained using the best technology currently... (8) Treating mine drainage in underground sumps. [44 FR 15422, Mar. 13, 1979, as amended at 48 FR...
Technical product bulletin: this bioremediation agent (biological additive/microbiological culture) for oil spill cleanups can be used on soil or open water. Soil should be broken up, and biodegradation is complete in approximately 12 to 18 weeks.
49 CFR 179.400-10 - Sump or siphon bowl.
Code of Federal Regulations, 2010 CFR
2010-10-01
... of weldable quality metal that is compatible with the inner tank shell; (b) The stress in any orientation under any condition does not exceed the circumferential stress in the inner tank shell; and (c...
40 CFR 264.226 - Monitoring and inspection.
Code of Federal Regulations, 2011 CFR
2011-07-01
... absence of tears, punctures, or blisters; and (2) Soil-based and admixed liners and covers must be... dimensions, and level that avoids backup into the drainage layer and minimizes head in the sump. [47 FR 32357...
40 CFR 264.226 - Monitoring and inspection.
Code of Federal Regulations, 2012 CFR
2012-07-01
... absence of tears, punctures, or blisters; and (2) Soil-based and admixed liners and covers must be... dimensions, and level that avoids backup into the drainage layer and minimizes head in the sump. [47 FR 32357...
40 CFR 264.226 - Monitoring and inspection.
Code of Federal Regulations, 2014 CFR
2014-07-01
... absence of tears, punctures, or blisters; and (2) Soil-based and admixed liners and covers must be... dimensions, and level that avoids backup into the drainage layer and minimizes head in the sump. [47 FR 32357...
40 CFR 264.226 - Monitoring and inspection.
Code of Federal Regulations, 2013 CFR
2013-07-01
... absence of tears, punctures, or blisters; and (2) Soil-based and admixed liners and covers must be... dimensions, and level that avoids backup into the drainage layer and minimizes head in the sump. [47 FR 32357...
40 CFR 264.226 - Monitoring and inspection.
Code of Federal Regulations, 2010 CFR
2010-07-01
... absence of tears, punctures, or blisters; and (2) Soil-based and admixed liners and covers must be... dimensions, and level that avoids backup into the drainage layer and minimizes head in the sump. [47 FR 32357...
44. AUXILIARY CHAMBER BETWEEN CHAMBER AND CONCRETE ENCLOSURE (LOCATION CCC), ...
44. AUXILIARY CHAMBER BETWEEN CHAMBER AND CONCRETE ENCLOSURE (LOCATION CCC), LOOKING NORTHEAST SHOWING DRAIN PIPE FROM SUMP - Shippingport Atomic Power Station, On Ohio River, 25 miles Northwest of Pittsburgh, Shippingport, Beaver County, PA
40 CFR 265.260 - Monitoring and inspection.
Code of Federal Regulations, 2010 CFR
2010-07-01
... a leak detection system under § 265.254 must record the amount of liquids removed from each leak detection system sump at least once each week during the active life and closure -period. [57 FR 3494, Jan...
14 CFR 25.1183 - Flammable fluid-carrying components.
Code of Federal Regulations, 2012 CFR
2012-01-01
... safeguard against the ignition of leaking flammable fluid. An integral oil sump of less than 25-quart..., essential services or equipment. [Doc. No. 5066, 29 FR 18291, Dec. 24, 1964, as amended by Amdt. 25-11, 32...
14 CFR 25.1183 - Flammable fluid-carrying components.
Code of Federal Regulations, 2011 CFR
2011-01-01
... safeguard against the ignition of leaking flammable fluid. An integral oil sump of less than 25-quart..., essential services or equipment. [Doc. No. 5066, 29 FR 18291, Dec. 24, 1964, as amended by Amdt. 25-11, 32...
Alternative Fuels Data Center: Equipment Options for E85 Fueling Systems
equipment includes an overfill protection device, a leak detection device, shear valves, fill and vapor caps protection, leak detection, shear valves, fill and vapor caps, adaptors, containment sumps, and all
49 CFR 179.400-10 - Sump or siphon bowl.
Code of Federal Regulations, 2013 CFR
2013-10-01
... metal that is compatible with the inner tank shell; (b) The stress in any orientation under any condition does not exceed the circumferential stress in the inner tank shell; and (c) The wall thickness is...
49 CFR 179.400-10 - Sump or siphon bowl.
Code of Federal Regulations, 2012 CFR
2012-10-01
... metal that is compatible with the inner tank shell; (b) The stress in any orientation under any condition does not exceed the circumferential stress in the inner tank shell; and (c) The wall thickness is...
14 CFR 25.1183 - Flammable fluid-carrying components.
Code of Federal Regulations, 2010 CFR
2010-01-01
... safeguard against the ignition of leaking flammable fluid. An integral oil sump of less than 25-quart..., essential services or equipment. [Doc. No. 5066, 29 FR 18291, Dec. 24, 1964, as amended by Amdt. 25-11, 32...
14 CFR 25.1183 - Flammable fluid-carrying components.
Code of Federal Regulations, 2013 CFR
2013-01-01
... safeguard against the ignition of leaking flammable fluid. An integral oil sump of less than 25-quart..., essential services or equipment. [Doc. No. 5066, 29 FR 18291, Dec. 24, 1964, as amended by Amdt. 25-11, 32...
49 CFR 179.400-10 - Sump or siphon bowl.
Code of Federal Regulations, 2011 CFR
2011-10-01
... metal that is compatible with the inner tank shell; (b) The stress in any orientation under any condition does not exceed the circumferential stress in the inner tank shell; and (c) The wall thickness is...
40 CFR 264.303 - Monitoring and inspection.
Code of Federal Regulations, 2012 CFR
2012-07-01
..., or blisters; and (2) Soil-based and admixed liners and covers must be inspected for imperfections... layer and minimizes head in the sump. [47 FR 32365, July 26, 1982, as amended at 50 FR 28748, July 15...
40 CFR 264.303 - Monitoring and inspection.
Code of Federal Regulations, 2014 CFR
2014-07-01
..., or blisters; and (2) Soil-based and admixed liners and covers must be inspected for imperfections... layer and minimizes head in the sump. [47 FR 32365, July 26, 1982, as amended at 50 FR 28748, July 15...
40 CFR 264.303 - Monitoring and inspection.
Code of Federal Regulations, 2010 CFR
2010-07-01
..., or blisters; and (2) Soil-based and admixed liners and covers must be inspected for imperfections... layer and minimizes head in the sump. [47 FR 32365, July 26, 1982, as amended at 50 FR 28748, July 15...
40 CFR 264.303 - Monitoring and inspection.
Code of Federal Regulations, 2013 CFR
2013-07-01
..., or blisters; and (2) Soil-based and admixed liners and covers must be inspected for imperfections... layer and minimizes head in the sump. [47 FR 32365, July 26, 1982, as amended at 50 FR 28748, July 15...
40 CFR 264.303 - Monitoring and inspection.
Code of Federal Regulations, 2011 CFR
2011-07-01
..., or blisters; and (2) Soil-based and admixed liners and covers must be inspected for imperfections... layer and minimizes head in the sump. [47 FR 32365, July 26, 1982, as amended at 50 FR 28748, July 15...
NASA Technical Reports Server (NTRS)
Seda, Jorge F. (Inventor); Dunbar, Lawrence W. (Inventor); Gliebe, Philip R. (Inventor); Szucs, Peter N. (Inventor); Brauer, John C. (Inventor); Johnson, James E. (Inventor); Moniz, Thomas (Inventor); Steinmetz, Gregory T. (Inventor)
2003-01-01
An aircraft gas turbine engine assembly includes an inter-turbine frame axially located between high and low pressure turbines. Low pressure turbine has counter rotating low pressure inner and outer rotors with low pressure inner and outer shafts which are at least in part rotatably disposed co-axially within a high pressure rotor. Inter-turbine frame includes radially spaced apart radially outer first and inner second structural rings disposed co-axially about a centerline and connected by a plurality of circumferentially spaced apart struts. Forward and aft sump members having forward and aft central bores are fixedly joined to axially spaced apart forward and aft portions of the inter-turbine frame. Low pressure inner and outer rotors are rotatably supported by a second turbine frame bearing mounted in aft central bore of aft sump member. A mount for connecting the engine to an aircraft is located on first structural ring.
AREVA Team Develops Sump Strainer Blockage Solution for PWRs
DOE Office of Scientific and Technical Information (OSTI.GOV)
Phan, Ray
2006-07-01
The purpose of this paper is to discuss the methodology, testing challenges, and results of testing that a team of experts from Areva NP, Alden Research Laboratory, Inc (ALDEN), and Performance Contracting Inc. (PCI) has developed. The team is currently implementing a comprehensive solution to the issue of Emergency Core Cooling System (ECCS) sump strainer blockage facing Pressurized Water Reactor (PWR) Nuclear Plants. The team has successfully demonstrated two key results from the testing of passive Sure-FlowTM strainers, which were designed to distribute the required flow over a large surface area resulting in extremely low approach velocities. First, the actualmore » head loss (pressure drop) as tested, across the prototype strainers, was much lower than the calculated head loss using the Nuclear Regulatory Commission (NRC) approved NUREG/CR-6224 head loss correlation. Second, the penetration fractions were much lower than those seen in the NRC sponsored debris penetration tests. (author)« less
49 CFR 179.100-13 - Venting, loading and unloading valves, measuring and sampling devices.
Code of Federal Regulations, 2010 CFR
2010-10-01
... permit testing thermometer well for leaks without complete removal of the closure may be used. (d) An... cast, forged or fabricated metal. Each sump or siphon bowl must be of good welding quality in...
LEACHATE CLOGGING ASSESSMENT OF GEOTEXTILE AND SOIL LANDFILL FILTERS
The liquids management strategy for any municipal or hazardous waste landfill requires a knowledgeable design strategy for the leachate collection system located at the base of the waste mass. Such leachate collection systems generally consist of sumps, perforated pipes, drainag...
97. VIEW OF MILL SOLUTION PUMP No. 2 FROM SOUTHEAST. ...
97. VIEW OF MILL SOLUTION PUMP No. 2 FROM SOUTHEAST. SUMPS ARE UNDER FLOOR, BEYOND. STAIR LEADS TO AGITATOR/GOLD TANK ACCESS PLATFORM. - Bald Mountain Gold Mill, Nevada Gulch at head of False Bottom Creek, Lead, Lawrence County, SD
49 CFR 393.65 - All fuel systems.
Code of Federal Regulations, 2011 CFR
2011-10-01
... towing it while the combination of vehicles is in motion; and (6) No part of the fuel system of a bus... enclosed in a protective housing must not extend more than 2 inches below the fuel tank or its sump. Diesel...
49 CFR 393.65 - All fuel systems.
Code of Federal Regulations, 2013 CFR
2013-10-01
... towing it while the combination of vehicles is in motion; and (6) No part of the fuel system of a bus... enclosed in a protective housing must not extend more than 2 inches below the fuel tank or its sump. Diesel...
49 CFR 393.65 - All fuel systems.
Code of Federal Regulations, 2012 CFR
2012-10-01
... towing it while the combination of vehicles is in motion; and (6) No part of the fuel system of a bus... enclosed in a protective housing must not extend more than 2 inches below the fuel tank or its sump. Diesel...
49 CFR 393.65 - All fuel systems.
Code of Federal Regulations, 2014 CFR
2014-10-01
... towing it while the combination of vehicles is in motion; and (6) No part of the fuel system of a bus... enclosed in a protective housing must not extend more than 2 inches below the fuel tank or its sump. Diesel...
40 CFR 421.326 - Pretreatment standards for new sources.
Code of Federal Regulations, 2014 CFR
2014-07-01
... GUIDELINES AND STANDARDS NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY Secondary Uranium Subcategory... wastewater pollutants in secondary uranium process wastewater introduced into a POTW shall not exceed the following values: (a) Refinery sump filtrate. PSNS for the Secondary Uranium Subcategory Pollutant or...
40 CFR 421.326 - Pretreatment standards for new sources.
Code of Federal Regulations, 2012 CFR
2012-07-01
... GUIDELINES AND STANDARDS NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY Secondary Uranium Subcategory... wastewater pollutants in secondary uranium process wastewater introduced into a POTW shall not exceed the following values: (a) Refinery sump filtrate. PSNS for the Secondary Uranium Subcategory Pollutant or...
40 CFR 421.326 - Pretreatment standards for new sources.
Code of Federal Regulations, 2013 CFR
2013-07-01
... GUIDELINES AND STANDARDS NONFERROUS METALS MANUFACTURING POINT SOURCE CATEGORY Secondary Uranium Subcategory... wastewater pollutants in secondary uranium process wastewater introduced into a POTW shall not exceed the following values: (a) Refinery sump filtrate. PSNS for the Secondary Uranium Subcategory Pollutant or...
IMPROVEMENTS IN PUMP INTAKE BASIN DESIGN
Pump intake basins (or wet wells or pump sumps) designed in accordance with accepted criteria often pose many operation and maintenance problems. The report summarizes field surveys of three trench-type pump intake basins representative of 29 such basins that have been in satisfa...
Recommendation of Sensors for Vehicle Transmission Diagnostics
2012-05-01
and a pressure switch module form the Control value module. A thermistor is contained within the pressure switch module in order to monitor the sump...fluid temperature. Sensor information is provided to the TCM through various sensors such as throttle position, speed sensor, pressure switch module
US researchers study effectiveness of Fluidized Sand Biofilters
USDA-ARS?s Scientific Manuscript database
Intensive aquaculture facilities generally produce two separate waste flows: 1) a high volume dilute discharge from culture tanks or pump sumps, and 2) a moderately small and solids-concentrated discharge typically backwashed from mechanical filtration units. The high volume dilute flow can appear p...
75 FR 15752 - Sunshine Act Notice
Federal Register 2010, 2011, 2012, 2013, 2014
2010-03-30
...)--191, Assessment of Debris Accumulation on Pressurized Water Reactor (PWR) Sump Performance (Public... Fuel Cycle Oversight Process Revisions (Public Meeting). (Contact: Michael Raddatz, 301-492-3108.) This..., Employee/Labor Relations and Work Life Branch, at 301-492-2230, TDD: 301-415-2100, or by e-mail at angela...
75 FR 18907 - Sunshine Federal Register Notice
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-13
...)-191, Assessment of Debris Accumulation on Pressurized Water Reactor (PWR) Sump Performance (Public... Fuel Cycle Oversight Process Revisions (Public Meeting). (Contact: Michael Raddatz, 301-492-3108.) This... Bolduc, Chief, Employee/Labor Relations and Work Life Branch, at 301-492-2230, TDD: 301-415-2100, or by e...
40 CFR 265.226 - Monitoring and inspection.
Code of Federal Regulations, 2012 CFR
2012-07-01
... operating level for two consecutive months, the amount of liquids in the sumps must be recorded at least... (CONTINUED) INTERIM STATUS STANDARDS FOR OWNERS AND OPERATORS OF HAZARDOUS WASTE TREATMENT, STORAGE, AND... period. (2) After the final cover is installed, the amount of liquids removed from each leak detection...
40 CFR 265.226 - Monitoring and inspection.
Code of Federal Regulations, 2010 CFR
2010-07-01
... operating level for two consecutive months, the amount of liquids in the sumps must be recorded at least... (CONTINUED) INTERIM STATUS STANDARDS FOR OWNERS AND OPERATORS OF HAZARDOUS WASTE TREATMENT, STORAGE, AND... period. (2) After the final cover is installed, the amount of liquids removed from each leak detection...
40 CFR 265.226 - Monitoring and inspection.
Code of Federal Regulations, 2011 CFR
2011-07-01
... operating level for two consecutive months, the amount of liquids in the sumps must be recorded at least... (CONTINUED) INTERIM STATUS STANDARDS FOR OWNERS AND OPERATORS OF HAZARDOUS WASTE TREATMENT, STORAGE, AND... period. (2) After the final cover is installed, the amount of liquids removed from each leak detection...
40 CFR 265.226 - Monitoring and inspection.
Code of Federal Regulations, 2013 CFR
2013-07-01
... operating level for two consecutive months, the amount of liquids in the sumps must be recorded at least... (CONTINUED) INTERIM STATUS STANDARDS FOR OWNERS AND OPERATORS OF HAZARDOUS WASTE TREATMENT, STORAGE, AND... period. (2) After the final cover is installed, the amount of liquids removed from each leak detection...
40 CFR 265.226 - Monitoring and inspection.
Code of Federal Regulations, 2014 CFR
2014-07-01
... operating level for two consecutive months, the amount of liquids in the sumps must be recorded at least... (CONTINUED) INTERIM STATUS STANDARDS FOR OWNERS AND OPERATORS OF HAZARDOUS WASTE TREATMENT, STORAGE, AND... period. (2) After the final cover is installed, the amount of liquids removed from each leak detection...
30 CFR 57.22310 - Electrical cables (I-C mines).
Code of Federal Regulations, 2013 CFR
2013-07-01
... Standards for Methane in Metal and Nonmetal Mines Equipment § 57.22310 Electrical cables (I-C mines). Electrical cables used to power submersible sump pumps shall be accepted or approved by MSHA as flame... be sealed to prevent entry of explosive gas or dust. [57 FR 61223, Dec. 23, 1992] ...
30 CFR 57.22310 - Electrical cables (I-C mines).
Code of Federal Regulations, 2014 CFR
2014-07-01
... Standards for Methane in Metal and Nonmetal Mines Equipment § 57.22310 Electrical cables (I-C mines). Electrical cables used to power submersible sump pumps shall be accepted or approved by MSHA as flame... be sealed to prevent entry of explosive gas or dust. [57 FR 61223, Dec. 23, 1992] ...
30 CFR 57.22310 - Electrical cables (I-C mines).
Code of Federal Regulations, 2012 CFR
2012-07-01
... Standards for Methane in Metal and Nonmetal Mines Equipment § 57.22310 Electrical cables (I-C mines). Electrical cables used to power submersible sump pumps shall be accepted or approved by MSHA as flame... be sealed to prevent entry of explosive gas or dust. [57 FR 61223, Dec. 23, 1992] ...
30 CFR 57.22310 - Electrical cables (I-C mines).
Code of Federal Regulations, 2011 CFR
2011-07-01
... Standards for Methane in Metal and Nonmetal Mines Equipment § 57.22310 Electrical cables (I-C mines). Electrical cables used to power submersible sump pumps shall be accepted or approved by MSHA as flame... be sealed to prevent entry of explosive gas or dust. [57 FR 61223, Dec. 23, 1992] ...
30 CFR 57.22310 - Electrical cables (I-C mines).
Code of Federal Regulations, 2010 CFR
2010-07-01
... Standards for Methane in Metal and Nonmetal Mines Equipment § 57.22310 Electrical cables (I-C mines). Electrical cables used to power submersible sump pumps shall be accepted or approved by MSHA as flame... be sealed to prevent entry of explosive gas or dust. [57 FR 61223, Dec. 23, 1992] ...
77 FR 72433 - Buy America Waiver Notification
Federal Register 2010, 2011, 2012, 2013, 2014
2012-12-05
... Submersible pumps (3 @ 3,000 gallons/minute), (1 Low Flow Submersible pump @ 1,000 gallons/minute), (1 Low Flow Sump Pump @ 20 gallons/minute) for rehabilitation of a pump station in the State of Illinois... appropriate to use non-domestic Main Submersible pumps (3 @ 3,000 gallons/minute), (1 Low Flow Submersible...
Gou, Perng-Fei; Townsend, Harold E.; Barbanti, Giancarlo
1994-01-01
A corium protection assembly includes a perforated base grid disposed below a pressure vessel containing a nuclear reactor core and spaced vertically above a containment vessel floor to define a sump therebetween. A plurality of layers of protective blocks are disposed on the grid for protecting the containment vessel floor from the corium.
14 CFR 25.999 - Fuel system drains.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fuel system drains. 25.999 Section 25.999... STANDARDS: TRANSPORT CATEGORY AIRPLANES Powerplant Fuel System Components § 25.999 Fuel system drains. (a) Drainage of the fuel system must be accomplished by the use of fuel strainer and fuel tank sump drains. (b...
14 CFR 25.999 - Fuel system drains.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Fuel system drains. 25.999 Section 25.999... STANDARDS: TRANSPORT CATEGORY AIRPLANES Powerplant Fuel System Components § 25.999 Fuel system drains. (a) Drainage of the fuel system must be accomplished by the use of fuel strainer and fuel tank sump drains. (b...
14 CFR 25.999 - Fuel system drains.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Fuel system drains. 25.999 Section 25.999... STANDARDS: TRANSPORT CATEGORY AIRPLANES Powerplant Fuel System Components § 25.999 Fuel system drains. (a) Drainage of the fuel system must be accomplished by the use of fuel strainer and fuel tank sump drains. (b...
14 CFR 25.999 - Fuel system drains.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Fuel system drains. 25.999 Section 25.999... STANDARDS: TRANSPORT CATEGORY AIRPLANES Powerplant Fuel System Components § 25.999 Fuel system drains. (a) Drainage of the fuel system must be accomplished by the use of fuel strainer and fuel tank sump drains. (b...
14 CFR 25.999 - Fuel system drains.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Fuel system drains. 25.999 Section 25.999... STANDARDS: TRANSPORT CATEGORY AIRPLANES Powerplant Fuel System Components § 25.999 Fuel system drains. (a) Drainage of the fuel system must be accomplished by the use of fuel strainer and fuel tank sump drains. (b...
40 CFR 264.304 - Response actions.
Code of Federal Regulations, 2010 CFR
2010-07-01
... into the leak detection system exceeds the action leakage rate for any sump, the owner or operator must... thereafter, as long as the flow rate in the leak detection system exceeds the action leakage rate, the owner... forth the actions to be taken if the action leakage rate has been exceeded. At a minimum, the response...
40 CFR 265.224 - Response actions.
Code of Federal Regulations, 2010 CFR
2010-07-01
... action plan. The response action plan must set forth the actions to be taken if the action leakage rate... paragraph (b) of this section. (b) If the flow rate into the leak detection system exceeds the action leakage rate for any sump, the owner or operator must: (1) Notify the Regional Administrator in writing of...
40 CFR 264.253 - Response actions.
Code of Federal Regulations, 2010 CFR
2010-07-01
... rate into the leak detection system exceeds the action leakage rate for any sump, the owner or operator... thereafter, as long as the flow rate in the leak detection system exceeds the action leakage rate, the owner... must set forth the actions to be taken if the action leakage rate has been exceeded. At a minimum, the...
40 CFR 264.223 - Response actions.
Code of Federal Regulations, 2010 CFR
2010-07-01
...) If the flow rate into the leak detection system exceeds the action leakage rate for any sump, the... action plan must set forth the actions to be taken if the action leakage rate has been exceeded. At a... action leakage rate has been exceeded, submit to the Regional Administrator the results of the analyses...
40 CFR 265.303 - Response actions.
Code of Federal Regulations, 2010 CFR
2010-07-01
... section. (b) If the flow rate into the leak detection system exceeds the action leakage rate for any sump... response action plan must set forth the actions to be taken if the action leakage rate has been exceeded... notification that the action leakage rate has been exceeded, submit to the Regional Administrator the results...
40 CFR 61.132 - Standard: Process vessels, storage tanks, and tar-intercepting sumps.
Code of Federal Regulations, 2013 CFR
2013-07-01
... POLLUTANTS National Emission Standard for Benzene Emissions from Coke By-Product Recovery Plants § 61.132... furnace or a foundry coke byproduct recovery plant shall enclose and seal all openings on each process... or operator of a furnace coke by-product recovery plant also shall comply with the requirements of...
40 CFR 61.132 - Standard: Process vessels, storage tanks, and tar-intercepting sumps.
Code of Federal Regulations, 2012 CFR
2012-07-01
... POLLUTANTS National Emission Standard for Benzene Emissions from Coke By-Product Recovery Plants § 61.132... furnace or a foundry coke byproduct recovery plant shall enclose and seal all openings on each process... or operator of a furnace coke by-product recovery plant also shall comply with the requirements of...
40 CFR 61.132 - Standard: Process vessels, storage tanks, and tar-intercepting sumps.
Code of Federal Regulations, 2014 CFR
2014-07-01
... POLLUTANTS National Emission Standard for Benzene Emissions from Coke By-Product Recovery Plants § 61.132... furnace or a foundry coke byproduct recovery plant shall enclose and seal all openings on each process... or operator of a furnace coke by-product recovery plant also shall comply with the requirements of...
40 CFR 61.132 - Standard: Process vessels, storage tanks, and tar-intercepting sumps.
Code of Federal Regulations, 2011 CFR
2011-07-01
... POLLUTANTS National Emission Standard for Benzene Emissions from Coke By-Product Recovery Plants § 61.132... furnace or a foundry coke byproduct recovery plant shall enclose and seal all openings on each process... or operator of a furnace coke by-product recovery plant also shall comply with the requirements of...
76 FR 39095 - Compatibility of Underground Storage Tank Systems With Biofuel Blends
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-05
... drinking water for nearly half of all Americans, the U.S. Environmental Protection Agency (EPA) regulates... components of the UST system, such as leak detection devices, sealants, and containment sumps, may not be... demonstration of compatibility. Some commenters suggested that EPA allow the National Work Group on Leak...
77 FR 19740 - Water Sources for Long-Term Recirculation Cooling Following a Loss-of-Coolant Accident
Federal Register 2010, 2011, 2012, 2013, 2014
2012-04-02
... NUCLEAR REGULATORY COMMISSION [NRC-2010-0249] Water Sources for Long-Term Recirculation Cooling... Regulatory Guide (RG) 1.82, ``Water Sources for Long-Term Recirculation Cooling Following a Loss-of-Coolant... regarding the sumps and suppression pools that provide water sources for emergency core cooling, containment...
40 CFR 265.15 - General inspection requirements.
Code of Federal Regulations, 2011 CFR
2011-07-01
... (2) a threat to human health. The owner or operator must conduct these in-spec-tions often enough to identify prob-lems in time to correct them before -they harm human health or the -environment. (b)(1) The... -and sump pumps) that are import-ant to preventing, detecting, or responding -to environmental or human...
Hey, I Got Sump'n To Tell You, An' It Cool! A Class for Children with Severe Language Disabilities.
ERIC Educational Resources Information Center
Monaco, Joan L.; Zaslow, Elinor L.
Discussed is an experimental demonstration class for children exhibiting severe language disabilities. Staff includes teacher-therapist, classroom aide, psychologist, audiologist, speech and language pathologists, and occupational therapist. A theoretical framework is provided through discussion of phonological, semantic and syntactic aspects of…
75 FR 13800 - Sunshine Federal Register Notice
Federal Register 2010, 2011, 2012, 2013, 2014
2010-03-23
..., Assessment of Debris Accumulation on Pressurized Water Reactor (PWR) Sump Performance (Public Meeting..., 2010. Week of April 26, 2010--Tentative Thursday, April 29, 2010 9:30 a.m. Briefing on the Fuel Cycle... and Work Life Branch, at 301-492-2230, TDD: 301-415-2100, or by e-mail at [email protected
40 CFR 265.15 - General inspection requirements.
Code of Federal Regulations, 2010 CFR
2010-07-01
....g., inoperative sump pump, leaking fitting, eroding dike, etc.). (4) The frequency of inspection may vary for the items on the schedule. However, the frequency should be based on the rate of deterioration... and frequencies called for in §§ 265.174, 265.193, 265.195, 265.226, 265.260, 265.278, 265.304, 265...
Numerical modeling of materials processes with fluid-fluid interfaces
NASA Astrophysics Data System (ADS)
Yanke, Jeffrey Michael
A numerical model has been developed to study material processes that depend on the interaction between fluids with a large discontinuity in thermophysical properties. A base model capable of solving equations of mass, momentum, energy conservation, and solidification has been altered to enable tracking of the interface between two immiscible fluids and correctly predict the interface deformation using a volume of fluid (VOF) method. Two materials processes investigated using this technique are Electroslag Remelting (ESR) and plasma spray deposition. ESR is a secondary melting technique that passes an AC current through an electrically resistive slag to provide the heat necessary to melt the alloy. The simulation tracks the interface between the slag and metal. The model was validated against industrial scale ESR ingots and was able to predict trends in melt rate, sump depth, macrosegregation, and liquid sump depth. In order to better understand the underlying physics of the process, several constant current ESR runs simulated the effects of freezing slag in the model. Including the solidifying slag in the imulations was found to have an effect on the melt rate and sump shape but there is too much uncertainty in ESR slag property data at this time for quantitative predictions. The second process investigated in this work is the deposition of ceramic coatings via plasma spray deposition. In plasma spray deposition, powderized coating material is injected into a plasma that melts and carries the powder towards the substrate were it impacts, flattening out and freezing. The impacting droplets pile up to form a porous coating. The model is used to simulate this rain of liquid ceramic particles impacting the substrate and forming a coating. Trends in local solidification time and porosity are calculated for various particle sizes and velocities. The predictions of decreasing porosity with increasing particle velocity matches previous experimental results. Also, a preliminary study was conducted to investigate the effects of substrate surface defects and droplet impact angle on the propensity to form columnar porosity.
40 CFR Table 4 to Subpart Wwww of... - Work Practice Standards
Code of Federal Regulations, 2012 CFR
2012-07-01
..., or sumps via covered troughs, pipes, or other covered conveyance that shields the resin from the... when they are being charged or filled, and vii. cover or shield from ambient air resin delivery systems... less may be open when active mixing is taking place, or during periods when they are in process (i.e...
40 CFR Table 4 to Subpart Wwww of... - Work Practice Standards
Code of Federal Regulations, 2014 CFR
2014-07-01
..., or sumps via covered troughs, pipes, or other covered conveyance that shields the resin from the... when they are being charged or filled, and vii. cover or shield from ambient air resin delivery systems... less may be open when active mixing is taking place, or during periods when they are in process (i.e...
40 CFR Table 4 to Subpart Wwww of... - Work Practice Standards
Code of Federal Regulations, 2013 CFR
2013-07-01
..., or sumps via covered troughs, pipes, or other covered conveyance that shields the resin from the... when they are being charged or filled, and vii. cover or shield from ambient air resin delivery systems... less may be open when active mixing is taking place, or during periods when they are in process (i.e...
40 CFR Table 4 to Subpart Wwww of... - Work Practice Standards
Code of Federal Regulations, 2011 CFR
2011-07-01
..., or sumps via covered troughs, pipes, or other covered conveyance that shields the resin from the... when they are being charged or filled, and vii. cover or shield from ambient air resin delivery systems... less may be open when active mixing is taking place, or during periods when they are in process (i.e...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-05-26
... section 1404(b) of the Act (``Drain Cover Standard''). In addition to the anti-entrapment devices or... system; gravity drainage system; automatic pump shut-off system or drain disablement. The Pool and Spa... the drain covers, anti-entrapment device/systems, sump or equalizer lines at the site; and report on...
Energy efficient engine. Core engine bearings, drives and configuration: Detailed design report
NASA Technical Reports Server (NTRS)
Broman, C. L.
1981-01-01
The detailed design of the forward and aft sumps, the accessory drive system, the lubrication system, and the piping/manifold configuration to be employed in the core engine test of the Energy Efficient Engine is addressed. The design goals for the above components were established based on the requirements of the test cell engine.
Code of Federal Regulations, 2010 CFR
2010-07-01
... FOR HAZARDOUS AIR POLLUTANTS National Emission Standard for Benzene Emissions from Coke By-Product... no detectable emissions, as indicated by an instrument reading of less than 500 ppm above background and visual inspections, as determined by the methods specified in § 61.245(c). (3) The provisions of...
40 CFR 61.132 - Standard: Process vessels, storage tanks, and tar-intercepting sumps.
Code of Federal Regulations, 2010 CFR
2010-07-01
... POLLUTANTS National Emission Standard for Benzene Emissions from Coke By-Product Recovery Plants § 61.132... system, or other enclosed point in the by-product recovery process where the benzene in the gas will be... or operator of a furnace coke by-product recovery plant also shall comply with the requirements of...
90. PORTLAND FILTER FLOOR FROM SOUTHEAST. CYANIDE FEED TOWER TO ...
90. PORTLAND FILTER FLOOR FROM SOUTHEAST. CYANIDE FEED TOWER TO SUMP, LOWER RIGHT QUADRANT. DIAGONAL PIPE IN UPPER RIGHT IS AIR LINE TO AGITATORS. LAUNDER PARALLEL TO LEFT EDGE (FILLED WITH DEBRIS) RUNS FROM PRIMARY THICKENER No. 2 TO GOLD TANK No. 2. - Bald Mountain Gold Mill, Nevada Gulch at head of False Bottom Creek, Lead, Lawrence County, SD
169. PORTLAND FILTER FLOOR FROM SOUTHEAST. CYANIDE FEED TOWER TO ...
169. PORTLAND FILTER FLOOR FROM SOUTHEAST. CYANIDE FEED TOWER TO SUMP, LOWER RIGHT QUADRANT. DIAGONAL PIPE IN UPPER RIGHT IS AIR LINE TO AGITATORS. LAUNDER PARALLEL TO LEFT EDGE (FILLED WITH DEBRIS) RUNS FROM PRIMARY THICKENER No. 2 TO GOLD TANK No. 2 - Bald Mountain Gold Mill, Nevada Gulch at head of False Bottom Creek, Lead, Lawrence County, SD
49 CFR 178.345-8 - Accident damage protection.
Code of Federal Regulations, 2010 CFR
2010-10-01
... accidental loss of lading. The device must break at no more than 70 percent of the load that would be... major radius of the tank shell. The device must break at no more than 70 percent of the load that would... for the loss of lading due to an accident. (1) Any dome, sump, or washout cover plate projecting from...
Code of Federal Regulations, 2011 CFR
2011-07-01
... Recovery Plants § 61.139 Provisions for alternative means for process vessels, storage tanks, and tar... scheduled replacement time means the day that is estimated to be 90 percent of the demonstrated bed life, as... days before the point in the cycle where the exceedance was detected); this is a second example of the...
Code of Federal Regulations, 2014 CFR
2014-07-01
... Recovery Plants § 61.139 Provisions for alternative means for process vessels, storage tanks, and tar... scheduled replacement time means the day that is estimated to be 90 percent of the demonstrated bed life, as... days before the point in the cycle where the exceedance was detected); this is a second example of the...
Code of Federal Regulations, 2013 CFR
2013-07-01
... Recovery Plants § 61.139 Provisions for alternative means for process vessels, storage tanks, and tar... scheduled replacement time means the day that is estimated to be 90 percent of the demonstrated bed life, as... days before the point in the cycle where the exceedance was detected); this is a second example of the...
Code of Federal Regulations, 2012 CFR
2012-07-01
... Recovery Plants § 61.139 Provisions for alternative means for process vessels, storage tanks, and tar... scheduled replacement time means the day that is estimated to be 90 percent of the demonstrated bed life, as... days before the point in the cycle where the exceedance was detected); this is a second example of the...
76 FR 62605 - Virginia Graeme Baker Pool and Spa Safety Act; Interpretation of Unblockable Drain
Federal Register 2010, 2011, 2012, 2013, 2014
2011-10-11
... the VGB Act defines an ``unblockable drain'' as ``a drain of any size and shape that a human body...'' as follows: A suction outlet defined as all components, including the sump and/or body, cover/grate...'' Body Blocking Element of ASME/ANSI A112.19.8-2007 and that the rated flow through the remaining open...
95. VIEW OF ZINC FEEDER FROM SOUTHEAST. NOTE FEEDER CONE ...
95. VIEW OF ZINC FEEDER FROM SOUTHEAST. NOTE FEEDER CONE AND PIPING FROM VACUUM RECEIVER ON LEFT. PRECIPITATE PUMP MOTOR MOUNT VISIBLE BELOW FEEDER STAIRS, PUMP AND MOTOR MISSING. SUMPS ARE LOCATED UNDER THIS FLOOR, WITH ACCESS TO HATCH TO THE RIGHT OF FEEDER STAIR. - Bald Mountain Gold Mill, Nevada Gulch at head of False Bottom Creek, Lead, Lawrence County, SD
Code of Federal Regulations, 2010 CFR
2010-10-01
... good welding quality in conjunction with the metal of the tank shell. When the sump or siphon bowl is... cylinder of revolution must have walls of such thickness and must be so reinforced that the stresses in the walls caused by a given internal pressure are not greater than the circumferential stress which would...
Code of Federal Regulations, 2010 CFR
2010-10-01
... be made of cast, forged, or fabricated metal. Each sump or siphon bowl must be of good welding... must have walls of such thickness and be so reinforced that the stresses in the walls caused by a given internal pressure are not greater than the circumferential stress which would exist under the same internal...
Code of Federal Regulations, 2013 CFR
2013-10-01
... be made of cast, forged, or fabricated metal. Each sump or siphon bowl must be of good welding... must have walls of such thickness and be so reinforced that the stresses in the walls caused by a given internal pressure are not greater than the circumferential stress which would exist under the same internal...
Code of Federal Regulations, 2014 CFR
2014-10-01
... be made of cast, forged, or fabricated metal. Each sump or siphon bowl must be of good welding... must have walls of such thickness and be so reinforced that the stresses in the walls caused by a given internal pressure are not greater than the circumferential stress which would exist under the same internal...
49 CFR 179.100-13 - Venting, loading and unloading valves, measuring and sampling devices.
Code of Federal Regulations, 2013 CFR
2013-10-01
... metal. Each sump or siphon bowl must be of good welding quality in conjunction with the metal of the... walls of such thickness and be so reinforced that the stresses in the walls caused by a given internal pressure are no greater than the circumferential stress that would exist under the same internal pressure...
Code of Federal Regulations, 2014 CFR
2014-10-01
... good welding quality in conjunction with the metal of the tank shell. When the sump or siphon bowl is... cylinder of revolution must have walls of such thickness and must be so reinforced that the stresses in the walls caused by a given internal pressure are not greater than the circumferential stress which would...
49 CFR 179.100-13 - Venting, loading and unloading valves, measuring and sampling devices.
Code of Federal Regulations, 2012 CFR
2012-10-01
... metal. Each sump or siphon bowl must be of good welding quality in conjunction with the metal of the... walls of such thickness and be so reinforced that the stresses in the walls caused by a given internal pressure are no greater than the circumferential stress that would exist under the same internal pressure...
Code of Federal Regulations, 2012 CFR
2012-10-01
... good welding quality in conjunction with the metal of the tank shell. When the sump or siphon bowl is... cylinder of revolution must have walls of such thickness and must be so reinforced that the stresses in the walls caused by a given internal pressure are not greater than the circumferential stress which would...
49 CFR 179.100-13 - Venting, loading and unloading valves, measuring and sampling devices.
Code of Federal Regulations, 2014 CFR
2014-10-01
... metal. Each sump or siphon bowl must be of good welding quality in conjunction with the metal of the... walls of such thickness and be so reinforced that the stresses in the walls caused by a given internal pressure are no greater than the circumferential stress that would exist under the same internal pressure...
Code of Federal Regulations, 2012 CFR
2012-10-01
... be made of cast, forged, or fabricated metal. Each sump or siphon bowl must be of good welding... must have walls of such thickness and be so reinforced that the stresses in the walls caused by a given internal pressure are not greater than the circumferential stress which would exist under the same internal...
49 CFR 179.100-13 - Venting, loading and unloading valves, measuring and sampling devices.
Code of Federal Regulations, 2011 CFR
2011-10-01
... metal. Each sump or siphon bowl must be of good welding quality in conjunction with the metal of the... walls of such thickness and be so reinforced that the stresses in the walls caused by a given internal pressure are no greater than the circumferential stress that would exist under the same internal pressure...
Code of Federal Regulations, 2013 CFR
2013-10-01
... good welding quality in conjunction with the metal of the tank shell. When the sump or siphon bowl is... cylinder of revolution must have walls of such thickness and must be so reinforced that the stresses in the walls caused by a given internal pressure are not greater than the circumferential stress which would...
Code of Federal Regulations, 2011 CFR
2011-10-01
... good welding quality in conjunction with the metal of the tank shell. When the sump or siphon bowl is... cylinder of revolution must have walls of such thickness and must be so reinforced that the stresses in the walls caused by a given internal pressure are not greater than the circumferential stress which would...
Code of Federal Regulations, 2011 CFR
2011-10-01
... be made of cast, forged, or fabricated metal. Each sump or siphon bowl must be of good welding... must have walls of such thickness and be so reinforced that the stresses in the walls caused by a given internal pressure are not greater than the circumferential stress which would exist under the same internal...
Withdrawal of gases and liquids from an in situ oil shale retort
Siegel, Martin M.
1982-01-01
An in situ oil shale retort is formed within a subterranean formation containing oil shale. The retort contains a fragmented permeable mass of formation particles containing oil shale. A production level drift extends below the fragmented mass, leaving a lower sill pillar of unfragmented formation between the production level drift and the fragmented mass. During retorting operations, liquid and gaseous products are recovered from a lower portion of the fragmented mass. A liquid outlet line extends from a lower portion of the fragmented mass through the lower sill pillar for conducting liquid products to a sump in the production level drift. Gaseous products are withdrawn from the fragmented mass through a plurality of gas outlet lines distributed across a horizontal cross-section of a lower portion of the fragmented mass. The gas outlet lines extend from the fragmented mass through the lower sill pillar and into the production level drift. The gas outlet lines are connected to a gas withdrawal manifold in the production level drift, and gaseous products are withdrawn from the manifold separately from withdrawal of liquid products from the sump in the production level drift.
Contamination source review for Building E5032, Edgewood Area, Aberdeen Proving Ground, Maryland
DOE Office of Scientific and Technical Information (OSTI.GOV)
Booher, M.N.; O`Reilly, D.P.; Smits, M.P.
1995-09-01
This report by Argonne National Laboratory (ANL) documents results of a contamination source review of Building E5032 at the Aberdeen Proving Ground (APG) in Maryland. The review included a historical records search, physical inspection, photographic documentation, geophysical investigation, and review of available records regarding underground storage tanks associated with Building E5032. The field investigations were performed by ANL during 1994 and 1995. Building E5032 (APG designation), originally known as Building 99, is located at the northwest comer of the intersection of Hoadley Road and Magnolia Road in the Edgewood Area of APG. It was constructed during World War I asmore » an incendiary bomb filling plant and in 1920s and 1930s maintained as a filling facility. During World War II the building was a pilot plant for the development of a dry white phosphorus filling process. Since then the building has been used for white phosphorus filling pilot studies. Most of the dry filling methods were developed in Building E5032 between 1965 and 1970. Other filling operations in Building E5032 have included mustard during the period shortly after World War II and triethyl aluminum (TEA) during the late 1960s and early 1970s. During the World War II period, the building was connected to the sanitary sewer system with one large and at least one small interior sump. There are also seven sumps adjacent to the exterior of the building: two on the west elevation, four near the four bays on the south elevation, and one at the northeast corner of the building. All of these sumps are connected with the chemical sewer system and received most, if not all, of the production operation wastewater. The discharge from this system was released into the east branch of Canal Creek; the discharge pipe was located southeast of Building E5032. There are no records indicating the use of Building E5032 after 1974, and it is assumed that the building has been out of service since that time.« less
Cooper, Richard J; Fitt, Peter; Hiscock, Kevin M; Lovett, Andrew A; Gumm, Lee; Dugdale, Steve J; Rambohul, Justin; Williamson, Antony; Noble, Lister; Beamish, James; Hovesen, Poul
2016-10-01
Agricultural point source pesticide pollution arising from contaminated machinery washings and accidental spillages pose a significant threat to river water and groundwater quality. In this study, we assess the effectiveness of a three-stage on-farm biobed for treating pesticide contaminated wastewater from a large (20 km(2)) commercial arable estate. The facility consisted of an enclosed machinery wash-down unit (stage 1), a 49 m(2) lined compost-straw-topsoil biobed (stage 2), and a 200 m(2) drainage field with a trickle irrigation system (stage 3). Pesticide concentrations were analysed in water samples collected fortnightly between November 2013 and November 2015 from the biobed input and output sumps and from 20 porous pots buried at 45 cm and 90 cm depth within the drainage field. The results revealed that the biobed removed 68-98% of individual pesticides within the contaminated washings, with mean total pesticide concentrations reducing by 91.6% between the biobed input and output sumps. Drainage field irrigation removed a further 68-99% of individual pesticides, with total mean pesticide concentrations reducing by 98.4% and 97.2% in the 45 cm and 90 cm depth porous pots, respectively. The average total pesticide concentration at 45 cm depth in the drainage field (57 μg L(-1)) was 760 times lower than the mean concentration recorded in the input sump (43,334 μg L(-1)). There was no evidence of seasonality in the efficiency of biobed pesticide removal, nor was there evidence of a decline in removal efficiency over the two-year monitoring period. However, higher mean total pesticide concentrations at 90 cm (102 μg L(-1)) relative to 45 cm (57 μg L(-1)) depth indicated an accumulation of pesticide residues deeper within the soil profile. Overall, the results presented here demonstrate that a three-stage biobed can successfully reduce pesticide pollution risk from contaminated machinery washings on a commercial farm. Copyright © 2016 Elsevier Ltd. All rights reserved.
Steam-jet Chiller for Army Field Kitchens
2009-08-01
Steam-Jet Test-Loop Schematic A vacuum pump removes air from the entire system on startup, and is occasionally used to expel air during...delivered to the tube and shell condenser. The steam is condensed and drains to the vacuum sump tank. 11 Periodically, the condensate pump ... Vacuum Roughing Pump The condenser must be held at vacuum to prevent air from insulating the condenser tubes or create a back-pressure that would
6. Credit BG. Detail view looking north at Building 4306 ...
6. Credit BG. Detail view looking north at Building 4306 (Boiler House) located at southwest corner of Building 4305 (Unicon Portable Hangar). Building retains its original World War II wooden construction and finish. Number sign for Building 4302 belongs to nearby sump pump structure (See HAER photo number CA-170-RR-1) - Edwards Air Force Base, North Base, Unicon Portable Hangar, First & C Streets, Boron, Kern County, CA
2014-12-01
MA January 2015 3 There are no existing underground stormwater drains in the area of the new Vandenberg Gate Complex. The addition of... stormwater management systems that utilize the pervious landscape, vegetative filtration, sediment removal, infiltration via bioswales, deep sump...Airmen Dormitory construction, a base-wide stormwater standard requires redevelopment projects to reduce stormwater rate and volume by 10% over the
PROCESS WATER BUILDING, TRA605. SECTIONS B, C AND D SHOW ...
PROCESS WATER BUILDING, TRA-605. SECTIONS B, C AND D SHOW RELATIONSHIP BETWEEN FLASH EVAPORATORS (ABOVE) AND SEAL AND SUMP TANKS (BELOW). BASEMENT FLOOR IS BELOW GRADE; FIRST FLOOR, ABOVE GRADE. SHIELDING TOLERANCES. BLAW-KNOX 3150-5-7, 8/1950. INL INDEX NO. 531-605-00-098-100012, REV. 2. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
Strehler, Emanuel E
2015-04-24
The plasma membrane calcium ATPases (PMCAs) are ATP-driven primary ion pumps found in all eukaryotic cells. They are the major high-affinity calcium extrusion system for expulsion of Ca(2+) ions from the cytosol and help restore the low resting levels of intracellular [Ca(2+)] following the temporary elevation of Ca(2+) generated during Ca(2+) signaling. Due to their essential role in the maintenance of cellular Ca(2+) homeostasis they were initially thought to be "sump pumps" for Ca(2+) removal needed by all cells to avoid eventual calcium overload. The discovery of multiple PMCA isoforms and alternatively spliced variants cast doubt on this simplistic assumption, and revealed instead that PMCAs are integral components of highly regulated multi-protein complexes fulfilling specific roles in calcium-dependent signaling originating at the plasma membrane. Biochemical, genetic, and physiological studies in gene-manipulated and mutant animals demonstrate the important role played by specific PMCAs in distinct diseases including those affecting the peripheral and central nervous system, cardiovascular disease, and osteoporosis. Human PMCA gene mutations and allelic variants associated with specific disorders continue to be discovered and underline the crucial role of different PMCAs in particular cells, tissues and organs. Copyright © 2015 Elsevier Inc. All rights reserved.
Understanding potential exposure sources of perfluorinated carboxylic acids in the workplace.
Kaiser, Mary A; Dawson, Barbara J; Barton, Catherine A; Botelho, Miguel A
2010-11-01
This paper integrates perspectives from analytical chemistry, environmental engineering, and industrial hygiene to better understand how workers may be exposed to perfluorinated carboxylic acids when handling them in the workplace in order to identify appropriate exposure controls. Due to the dramatic difference in physical properties of the protonated acid form and the anionic form, this family of chemicals provides unique industrial hygiene challenges. Workplace monitoring, experimental data, and modeling results were used to ascertain the most probable workplace exposure sources and transport mechanisms for perfluorooctanoic acid (PFOA) and its ammonium salt (APFO). PFOA is biopersistent and its measurement in the blood has been used to assess human exposure since it integrates exposure from all routes of entry. Monitoring suggests that inhalation of airborne material may be an important exposure route. Transport studies indicated that, under low pH conditions, PFOA, the undissociated (acid) species, actively partitions from water into air. In addition, solid-phase PFOA and APFO may also sublime into the air. Modeling studies determined that contributions from surface sublimation and loss from low pH aqueous solutions can be significant potential sources of workplace exposure. These findings suggest that keeping surfaces clean, preventing accumulation of material in unventilated areas, removing solids from waste trenches and sumps, and maintaining neutral pH in sumps can lower workplace exposures.
DWPF DECON FRIT SUPERNATE ANALYSIS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Peeler, D.; Crawford, C.
2010-09-22
The Savannah River National Laboratory (SRNL) has been requested to perform analyses on samples of the Defense Waste Processing Facility (DWPF) decon frit slurry (i.e., supernate samples and sump solid samples). Four 1-L liquid slurry samples were provided to SRNL by Savannah River Remediation (SRR) from the 'front-end' decon activities. Additionally, two 1-L sump solids samples were provided to SRNL for compositional and physical analysis. This report contains the results of the supernate analyses, while the solids (sump and slurry) results will be reported in a supplemental report. The analytical data from the decon frit supernate indicate that all ofmore » the radionuclide, organic, and inorganic concentrations met the limits in Revision 4 of the Effluent Treatment Plant (ETP) Waste Acceptance Criteria (WAC) with the exception of boron. The ETP WAC limit for boron is 15.0 mg/L while the average measured concentration (based on quadruplicate analysis) was 15.5 mg/L. The measured concentrations of Li, Na, and Si were also relatively high in the supernate analysis. These results are consistent with the relatively high measured value of B given the compositional make-up of Frit 418. Given these results, it was speculated that either (a) Frit 418 was dissolving into the supernate or aqueous fraction and/or (b) fine frit particulates were carried forward to the analytical instrument based on the sampling procedure used (i.e., the supernate samples were not filtered - only settled with the liquid fraction being transferred with a pipette). To address this issue, a filtered supernate sample (using a 0.45 um filter) was prepared and submitted for analysis. The results of the filtered sample were consistent with 'unfiltered or settled' sample - relatively high values of B, Li, Na, and Si were found. This suggests that Frit 418 is dissolving in the liquid phase which could be enhanced by the high surface area of the frit fines or particulates in suspension. Based on the results of this study, it is recommended that DWPF re-evaluate the technical basis for the B WAC limit (the only component that exceeds the ETP WAC limit from the supernate analyses) or assess if a waiver or exception can be obtained for exceeding this limit. Given the possible dissolution of B, Li, Na, and Si into the supernate (due to dissolution of frit), DWPF may need to assess if the release of these frit components into the supernate are a concern for the disposal options being considered. It should be noted that the results of this study may not be representative of future decon frit solutions or sump/slurry solids samples. Therefore, future DWPF decisions regarding the possible disposal pathways for either the aqueous or solid portions of the Decon Frit system need to factor in the potential differences. More specifically, introduction of a different frit or changes to other DWPF flowsheet unit operations (e.g., different sludge batch or coupling with other process streams) may impact not only the results but also the conclusions regarding acceptability with respect to the ETF WAC limits.« less
Antivortex Device for Multi-Outlet Liquid Reservoir
NASA Technical Reports Server (NTRS)
Grayson, Gary David (Inventor); Addison, Stephen Michael (Inventor)
2016-01-01
A liquid reservoir with a sump includes at least two outlet ports in fluid communication with a fluid conduit. An anti-vortex device includes a first plate extending across the at least two outlet ports and a second plate coupled to the first plate and extending substantially perpendicular to the first plate. The anti-vortex device is configured to disrupt formation of a vortex formed by liquid passing from the reservoir through said outlet ports.
Axial-Centrifugal Compressor Program
1975-10-01
chip detector, but they were not large enough to trigger the alarm circuit. These chips we-e analyzed as M50 bearing material, which was a positive...but an analysis of these particles indicated M50 bearing material and positively identified a thrust bearing problem. 50 ’ ! i VI Figure 18. Load Cel...load cell readout became erratic and the vehicle was shut down. An inspection showed that the aft bearing sump chip detector contained M50 bearing
ERIC Educational Resources Information Center
2002
The Media Ethics division of the proceedings contains the following 6 papers: "A Masochist's Teapot: Where to Put the Handle in Media Ethics" (Thomas W. Hickey); "Stalker-razzi and Sump-pump Hoses: The Role of the Media in the Death of Princess Diana" (Elizabeth Blanks Hindman); "The Promise and Peril of Anecdotes in News…
Sump bay fever: inhalational fever associated with a biologically contaminated water aerosol.
Anderson, K; McSharry, C P; Clark, C; Clark, C J; Barclay, G R; Morris, G P
1996-01-01
OBJECTIVE: To investigate the clinical, serological, and environmental features of a work related inhalational fever associated with exposure to an aerosol generated from a biologically contaminated 130,000 gallon water pool in a building used for testing scientific equipment. METHOD: Cross sectional survey of all exposed subjects (n = 83) by symptom questionnaire, clinical examination, spirometry, and serology for antibody to Pseudomonads, pool water extract, and endotoxin. In symptomatic patients diffusion capacity was measured, and chest radiology was performed if this was abnormal. Serial peak flow was recorded in those subjects with wheeze. Bacterial and fungal air sampling was performed before and during operation of the water pool pump mechanism. Endotoxin was measured in the trapped waters and in the pumps. Serum cotinine was measured as an objective indicator of smoking. RESULTS: Of the 20 symptomatic subjects, fever was most common in those with the highest exposure (chi 2 42.7, P < 0.001) in the sump bay when the water was (torrentially) recirculated by the water pumps. Symptoms occurred late in the working day only on days when the water pumps were used, and were independent of the serum cotinine. Pulmonary function was normal in most subjects (spirometry was normal in 79/83, diffusion capacity was low in five subjects, chest radiology was normal). Peak flow recording did not suggest a work relation. The bacterial content of the aerosol rose from 6 to > 10,000 colony forming units per cubic metre (cfu/m3) (predominantly environmental Pseudomonads) when the pumps were operating. High endotoxin concentrations were measured in the waters and oil sumps in the pumps. Low concentrations of antibody to the organisms isolated were detected (apart from two subjects with high antibody) but there was no relation to exposure or the presence of symptoms and similar antibody was found in the serum samples from a non-exposed population. The fever symptoms settled completely with the simple expedient of changing the water and cleaning the pumps. CONCLUSION: Given the results of our study, the development of inhalational fever in this unique environment and clearly restricted cohort was closely related to the degree of exposure to contaminated aerosol and mainly occurred in the absence of distinct serological abnormality and independent of cigarette smoking. PMID:8777446
Utility Distribution Systems in Sweden, Finland, Norway and England
1976-11-01
the duct adds to the water protection and sumps, with access for pumping, are provided -at low points. Glass wool or mineral wool insulation is placed...mm thick, is glass, mineral wool or polyurethane foam. The outer pipe is steel, polyurethane or asbestos cement coupled with O-ring seals. Asbestos...decided that asbestos cement should be replaced by less dangerous materials. Some use is made of steel, plastic or copper tubes with mineral wool or
111. DETAIL OF FILTER DISCS ON DENVER FILTER IN CO91107. ...
111. DETAIL OF FILTER DISCS ON DENVER FILTER IN CO-91-107. AS DISCS SLOWLY ROTATE, VACUUM INSIDE DISCS ATTRACT SLURRY IN THE SUMP AND DEWATERS CONCENTRATE AS DISCS MOVE THROUGH AIR. FURTHER ROTATION PASSES A BAR TO SCRAPE OFF DRIED METAL CONCENTRATE, ASSISTED BY BLASTS OF COMPRESSED AIR. METAL CONCENTRATE READY FOR SHIPMENT TO SMELTER FALLS INTO BIN BELOW. EIMCO FILTERS OPERATE SIMILARLY. - Shenandoah-Dives Mill, 135 County Road 2, Silverton, San Juan County, CO
Development of the Automated AFAPL Engine Simulator Test for Lubricant Evaluation.
1981-05-01
including foreign nations. This technical report has been reviewed and is approved for publication. LEON 4JDEBROtUN R.D. DAYTO,*tighief Project Engineer...flow is jetted into the front and rear of the simulator gearbox to provide additional cooling to the gearbox. A heat exchanger is used to cool the oil...flow to the gearbox. Additional heat exchangers are used in the simulator and gearbox oil return lines to the external sump. The simulator test
1968-08-01
workers in 1958 on Doi Suthep mountain near Chiang Mai . Additional specimens in the SEATO collection were made by human biting collections, or...to be restricted to forested hills. The specimens taken in the human biting collections at Chiang Mai \\vere not permitted to engorge, and the biting...ditches, seepages, and sumps. Distribution in Thailand: Ayutthaya, Chanthaburi, Chiang Mai , Chon Buri, Phra Nakhon (Bangkok), Nakhon Nayok, Nakhon
History of the Biak Operation, 15-27 June 1944
1944-01-01
interconnected by fissures and tunnels. Stalactites and stalagmites add to the near impregnability of the caves as defensive positions. Biak appears to be...level series of intermittently connected cavities about 4 to 8 feet in height and 3 to 6 feet in depth. Stalactite - stalagmite unions and hard...entrance invisible at six paces. In "sump" caves, screening may consist of stalactites and stalagmites which do not conceal the cave mouth, but stop or
Understanding Potential Exposure Sources of Perfluorinated Carboxylic Acids in the Workplace
Kaiser, Mary A.; Dawson, Barbara J.; Barton, Catherine A.; Botelho, Miguel A.
2010-01-01
This paper integrates perspectives from analytical chemistry, environmental engineering, and industrial hygiene to better understand how workers may be exposed to perfluorinated carboxylic acids when handling them in the workplace in order to identify appropriate exposure controls. Due to the dramatic difference in physical properties of the protonated acid form and the anionic form, this family of chemicals provides unique industrial hygiene challenges. Workplace monitoring, experimental data, and modeling results were used to ascertain the most probable workplace exposure sources and transport mechanisms for perfluorooctanoic acid (PFOA) and its ammonium salt (APFO). PFOA is biopersistent and its measurement in the blood has been used to assess human exposure since it integrates exposure from all routes of entry. Monitoring suggests that inhalation of airborne material may be an important exposure route. Transport studies indicated that, under low pH conditions, PFOA, the undissociated (acid) species, actively partitions from water into air. In addition, solid-phase PFOA and APFO may also sublime into the air. Modeling studies determined that contributions from surface sublimation and loss from low pH aqueous solutions can be significant potential sources of workplace exposure. These findings suggest that keeping surfaces clean, preventing accumulation of material in unventilated areas, removing solids from waste trenches and sumps, and maintaining neutral pH in sumps can lower workplace exposures. PMID:20974675
NASA Astrophysics Data System (ADS)
Li, Hu-Tian; Zhao, Pizhi; Yang, Rongdong; Patel, Jayesh B.; Chen, Xiangfu; Fan, Zhongyun
2017-10-01
Melt-conditioned, direct-chill (MC-DC) casting is an emerging technology to manipulate the solidification process by melt conditioning via intensive shearing in the sump during DC casting to tailor the solidification microstructure and defect formation. When using MC-DC casting technology in an industrial scale DC cast billet of an A4032 aluminum alloy, significant grain refinement and uniform microstructure can be achieved in the primary α-Al phase with fine secondary dendritic arm spacing (SDAS). Improved macrosegregation is quantitatively characterized and correlated with the suppression of channel segregation. The mechanisms for the prevention of channel segregation are attributed to the increased local cooling rate in the liquid-solid phase region in the sump and the formation of fine equiaxed dendritic grains under intensive melt shearing during MC-DC casting. A critical cooling rate has been identified to be around 0.5 to 1 K/s (°C/s) for the channel segregation to happen in the investigated alloy based on quantitative metallographic results of SDAS. Reduction and refinement of microporosity is attributed to the improved permeability in the liquid-solid phase region estimated by the Kozeny-Carman relationship. The potential improvement in the mechanical properties achievable in MC-DC cast billets is indicated by the finer and more uniform forging streamline in the forgings of MC-DC cast billet.
27. VIEW OF CENTRAL SECTION OF MILL FROM NORTHEAST. LEVELS ...
27. VIEW OF CENTRAL SECTION OF MILL FROM NORTHEAST. LEVELS OF MILL VISIBLE IN ROOF LINES INCLUDE CRUSHED OXIDIZED ORE BIN (OPEN FRAMING, TOP CENTER), MILLING FLOOR (FIRST ROOF DOWN FROM ORE BIN), LEACHING/OLD SAND TANK LEVEL (SHALLOWER SECOND ROOF DOWN), GOLD TANK/AGITATOR LEVEL (CENTER), AND PRECIPITATION LEVEL WITH SUMP LEVEL BELOW (LOWER RIGHT). ROOF BREAKS ALLOWED FOR CLERESTORY WINDOWS WHICH ILLUMINATED THE INTERIORS, ALONG WITH DORMERS. - Bald Mountain Gold Mill, Nevada Gulch at head of False Bottom Creek, Lead, Lawrence County, SD
2013-12-01
experimental studies and analyses performed and the resulting recommendations. Results from the present effort indicated that a minimum use limit of... experimental studies performed and the resulting recommendations regarding the minimum on-board use limit of FSII while maintaining safe operability...sumping. A detailed summary of the experimental efforts and results are provided in a separate report (Balster et al., 2010). For the ATCC
4. Credit GE. Photographic copy of photograph, looking northeast into ...
4. Credit GE. Photographic copy of photograph, looking northeast into 'A' stand flame trench as seen from the southeast corner of 'A' stand foundation. The concrete construction at the bottom of the trench is a water pond with sump for cooling rocket engine plumes before they blow into the desert to the east. (JPL negative no. 383-940-B, 29 August 1945) - Jet Propulsion Laboratory Edwards Facility, Test Stand A, Edwards Air Force Base, Boron, Kern County, CA
NASA Astrophysics Data System (ADS)
Danielson, Dennis R.
2001-10-01
For more than three centuries scientists, historians, and popularizers of science have been repeating the claim that Copernicus ``dethroned'' earth from its ``privileged'' central position in the universe. However, a survey of pre-Copernican natural philosophy (which viewed the earth as located in a cosmic sump) and of Copernicans' own account of the axiological meaning of the new heliocentric astronomy (which exalted earth to the dance of the stars) demonstrates that the cliché about earth's ``demotion'' is unwarranted and fit to be discarded.
Improved Fatigue Life Bearing Development
1989-06-01
lubricating conditions: (1) oil sump, with the bottom rolling element half submerged in oil; (2) oil vapor, with the bearings bathed in oil vapor rising from...the life of bearings operating at speeds up to 3 MDN. A 40-rnm thrust bearing (Fafnir 2AAM 208WO MBR ) was selected for the preliminary tests. Bearings...Bore Ball Bearing Test Rig. 56 P- Aft. C9) 57 The test bearings (Fafnir 2AAM 208W0 MBR ) were manufactured out of VIM-VAR M50. Initial testing was
McManus, B.C.; Schreffler, C.L.; Rowland, C.J.
1994-01-01
A map showing ground-water levels in Buckingham and Wrightstown Townships, Bucks County, Pennsylvania, was constructed from water levels measured in 251 wells and from 3 reported elevations of quarry sumps from June 1992 through January 1993. Observed water-level altitudes range from 459 feet above sea level along Burnt House Hill Road, south- west of Mechanicsville, to 10 feet above sea level along Swamp Road and Route 232, near Neshaminy Creek in Wrightstown Township.
Fukushima Daiichi Unit 1 Ex-Vessel Prediction: Core-Concrete Interaction
DOE Office of Scientific and Technical Information (OSTI.GOV)
Robb, Kevin R.; Farmer, Mitchell T.; Francis, Matthew W.
Lower head failure and corium-concrete interaction were predicted to occur at Fukushima Daiichi Unit 1 (1F1) by several different system-level code analyses, including MELCOR v2.1 and MAAP5. Although these codes capture a wide range of accident phenomena, they do not contain detailed models for ex-vessel core melt behavior. However, specialized codes exist for the analysis of ex-vessel melt spreading (e.g., MELTSPREAD) and long-term debris coolability (e.g., CORQUENCH). On this basis, in this paper an analysis was carried out to further evaluate ex-vessel behavior for 1F1 using MELTSPREAD and CORQUENCH. Best-estimate melt pour conditions predicted by MELCOR v2.1 and MAAP5 weremore » used as input. MELTSPREAD was then used to predict the spatially dependent melt conditions and extent of spreading during relocation from the vessel. The results of the MELTSPREAD analysis are reported in a companion paper. This information was used as input for the long-term debris coolability analysis with CORQUENCH. For the MELCOR-based melt pour scenario, CORQUENCH predicted the melt would readily cool within 2.5 h after the pour, and the sumps would experience limited ablation (approximately 18 cm) under water-flooded conditions. Finally, for the MAAP-based melt pour scenarios, CORQUENCH predicted that the melt would cool in approximately 22.5 h, and the sumps would experience approximately 65 cm of concrete ablation under water-flooded conditions.« less
Fukushima Daiichi Unit 1 Ex-Vessel Prediction: Core-Concrete Interaction
Robb, Kevin R.; Farmer, Mitchell T.; Francis, Matthew W.
2016-10-31
Lower head failure and corium-concrete interaction were predicted to occur at Fukushima Daiichi Unit 1 (1F1) by several different system-level code analyses, including MELCOR v2.1 and MAAP5. Although these codes capture a wide range of accident phenomena, they do not contain detailed models for ex-vessel core melt behavior. However, specialized codes exist for the analysis of ex-vessel melt spreading (e.g., MELTSPREAD) and long-term debris coolability (e.g., CORQUENCH). On this basis, in this paper an analysis was carried out to further evaluate ex-vessel behavior for 1F1 using MELTSPREAD and CORQUENCH. Best-estimate melt pour conditions predicted by MELCOR v2.1 and MAAP5 weremore » used as input. MELTSPREAD was then used to predict the spatially dependent melt conditions and extent of spreading during relocation from the vessel. The results of the MELTSPREAD analysis are reported in a companion paper. This information was used as input for the long-term debris coolability analysis with CORQUENCH. For the MELCOR-based melt pour scenario, CORQUENCH predicted the melt would readily cool within 2.5 h after the pour, and the sumps would experience limited ablation (approximately 18 cm) under water-flooded conditions. Finally, for the MAAP-based melt pour scenarios, CORQUENCH predicted that the melt would cool in approximately 22.5 h, and the sumps would experience approximately 65 cm of concrete ablation under water-flooded conditions.« less
Person, Abraham
1980-01-01
In an ocean thermal energy conversion facility, a cold water riser pipe is releasably supported at its upper end by the hull of the floating facility. The pipe is substantially vertical and has its lower end far below the hull above the ocean floor. The pipe is defined essentially entirely of a material which has a modulus of elasticity substantially less than that of steel, e.g., high density polyethylene, so that the pipe is flexible and compliant to rather than resistant to applied bending moments. The position of the lower end of the pipe relative to the hull is stabilized by a weight suspended below the lower end of the pipe on a flexible line. The pipe, apart from the weight, is positively buoyant. If support of the upper end of the pipe is released, the pipe sinks to the ocean floor, but is not damaged as the length of the line between the pipe and the weight is sufficient to allow the buoyant pipe to come to a stop within the line length after the weight contacts the ocean floor, and thereafter to float submerged above the ocean floor while moored to the ocean floor by the weight. The upper end of the pipe, while supported by the hull, communicates to a sump in the hull in which the water level is maintained below the ambient water level. The sump volume is sufficient to keep the pipe full during heaving of the hull, thereby preventing collapse of the pipe.
1989-10-01
Coord: Elev.PROTECTIVE CSG He~qht I Material /Type El e~. ________Diameter Elie.hI____ Depth BGS ___________Weep Hole (YIN) HSe.ht __ GUARD POSTS (YIN...Tremied I Y/14) SCR EE N Type Dimeter - --Slot Size Ck Type SUMP (YIN) Interval OGS Lcngth - 90tt0m Cop (YIN) BACKFILL PLUG Material ...for transport to the laboratory. The remaining liners will then be extruded and the material used for lithologic description and other analyses. The
The effect of alcohol blends on the performance of an air cooled Rotary Trochoidal Engine
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gutman, M.; Iuster, I.
Results obtained from tests on an air cooled Rotary Trochoidal Engine fueled with a gasoline-alcohol mixture, without modification of the carburetor, are presented in this paper. The tests were performed with one and two spark plugs. Amongst the obtained results, lower thermal load, better economy and improvement in cycling uniformity when running with two spark plugs were observed. The observed reduction in the rotor housing wall temperature and in the oil sump temperature presents particular advantages for an air cooled engine.
The effect of alcohol blends on the performance of an air cooled rotary trochoidal engine
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gutman, M.; Iuster, I.
Results obtained from tests on an air cooled Rotary Trochoidal Engine fueled with a gasoline-alcohol mixture, without modification of the carburetor, are presented in this paper. The tests were performed with one and two spark plugs. Amongst the obtained results, lower thermal load, better economy and improvement in cycling uniformity when running with two spark plugs were observed. The observed reduction in the rotor housing wall temperature and in the oil sump temperature presents particular advantages for an air cooled engine.
Hydrologic data for aquifers in Philadelphia, Pennsylvania
Paulachok, G.N.; Wood, C.R.; Norton, L.J.
1984-01-01
Selected data on the ground-water resources of Philadelphia, Pennsylvania, are presented in this report. Information including water levels and data on aquifers is tabulated for 828 wells and 3 sumps. Chemical analyses are given for 1,467 water samples obtained from 205 sites and include 103 analyses for trace elements and 68 analyses for volatile organic compounds. An index of geophysical logs including gamma ray, neutron, caliper, fluid conductivity, fluid velocity, single-point resistance, spontaneous potential, and temperature determinations made in 51 wells is also presented. Data-collection sites are shown on a 1:50,000 scale location map.
NASA Astrophysics Data System (ADS)
1982-09-01
The complete Barstow Solar Pilot Plant is described. The plant requirements and general description are presented, the mechanical, electric power, and control and instrumentation systems as well as civil engineering and structural aspects and the station buildings are described. Included in the mechanical systems are the heliostats, receiver, thermal storage system, beam characterization system, steam, water, nitrogen, and compressed air systems, chemical feed system, fire protection system, drains, sumps and the waste disposal systems, and heating, ventilating, and air conditioning systems.
13. CLOSEUP OF AFT BULKHEAD IN THE MAIN HOLD. HORIZONTAL ...
13. CLOSE-UP OF AFT BULKHEAD IN THE MAIN HOLD. HORIZONTAL ALUMINUM SCALE RESTING ON STEP IS FOUR FEET LONG. THE BOTTOM OF THE HOLD IS MADE OF POURED CONCRETE AND HAS A CENTER DRAIN TO COLLECT WATER FROM MELTING ICE AND OTHER FLUIDS. THE DRAIN LED TO A SUMP CLEARED BY A BILGE PUMP WHICH PUMPED OVERBOARD. THE RECTANGULAR OPENING IN THE BULKHEAD WAS CUT TO ENABLE EASIER REMOVAL OF THE ENGINE AFTER THE EVELINA M. GOULART WAS ABANDONED. - Auxiliary Fishing Schooner "Evelina M. Goulart", Essex Shipbuilding Museum, 66 Main Street, Essex, Essex County, MA
Impacts to Dungeness Crab from the Southwest Washington Littoral Drift Restoration Project
DOE Office of Scientific and Technical Information (OSTI.GOV)
Williams, Greg D.; Kohn, Nancy P.; Pearson, Walter H.
2005-11-09
The Benson Beach littoral drift restoration project is a demonstration project that will replenish sand on Benson Beach, the public beach north of the North Jetty at the mouth of the Columbia River (MCR), using material dredged from the river during normal maintenance dredging of the navigational channel. A U.S. Army Corps of Engineers (Corps) proposal involves pumping the material from a sump area on the south side of the jetty to Benson Beach using a cutter suction dredge, also known as a pipeline dredge. If this one-time demonstration project proves feasible and successful, up to a million cubic yardsmore » of sediment could be used to replenish the outer coast littoral drift system in successive years by the same process. The primary goal of this study was to assess the potential risk of impacts to Dungeness crab from the proposed Benson Beach littoral drift restoration process of using the cutter suction dredge to move sediment from the proposed sump area on one side of the North Jetty to the beach on the other side of the jetty. Because there are no direct measurements of crab entrainment by pipeline dredge operating outside of the lower Columbia River navigation channel, dredge impacts for the proposed demonstration project were estimated using a modification of the dredge impact model (DIM) of Armstrong et al. (1987). The model estimates adult equivalent loss (AEL) of crabs using crab population density from trawl surveys, dredge project information (gear type, season, location, volume), and an entrainment function relating crab population density to entrainment by the dredge. The input used in applying the DIM to the Benson Beach littoral drift restoration included the specific dredging scenario provided by the Corps, existing data on crab density in previously proposed sump areas, and a series of entrainment functions. A total of fourteen scenarios were modeled and the outcomes compared with six reference scenarios intended to represent realistic to worst cases. Dungeness crab entrainment and subsequent loss of recruitment to adult age classes and the crab fishery estimated for the Benson Beach littoral drift restoration project varied widely (over three orders of magnitude) because of the range of assumptions about initial crab density, dredging scenarios, and entrainment functions. Although the comparison to reference scenarios helps put the results in perspective, losses to the crab fishery could still span two orders of magnitude. This uncertainty can only be assessed by direct measurements of crab entrainment during the demonstration project if crab losses are to be more accurately estimated for the demonstration, which is recommended in order to evaluate cumulative crab losses from successive replenishment efforts.« less
Zhou, Bo; Ren, Jianan; Han, Gang; Chen, Yu; A, Jiye; Gu, Guosheng; Chen, Jun; Wang, Gefei; Li, Jieshou
2014-04-01
Low serum albumin concentration is a predictor of failure of source control for intra-abdominal infection. However, data on dynamics of albumin synthesis in these patients and to what extent these changes contribute to hypoalbuminemia are relatively scarce. We investigated in a group of patients with gastrointestinal fistula the dynamic response of liver albumin synthesis to intra-abdominal abscess and how these related to hypoalbuminemia and circulating endocrine hormone profiles. Eight gastrointestinal fistula patients scheduled to undergo percutaneous abscess sump drainage were enrolled prospectively to measure albumin synthesis rates at different stages of the inflammatory response (immediately after diagnosis and 7 d following sump drainage when clinical signs of intra-abdominal sepsis had been eradicated). Eight age-, sex-, and body mass index-matched intestinal fistula patients were studied as control patients. Consecutive arterial blood samples were drawn during a primed-constant infusion (priming dose: 4 micromol·kg(-1), infusion rate: 6 micromol·kg(-1)·min(-1)) to determine the incorporation rate of L-[ring-(2)H5]-phenylalanine directly into plasma albumin using gas chromatography/mass spectrometry analysis. Patients suffering from intra-abdominal infection had reduced plasma albumin and total plasma protein concentrations, compared with control patients. Albumin fractional synthesis rates in patients with intra-abdominal abscess were decreased, compared with those in the control group. When the source of infection was removed, albumin synthesis rates returned to control values, whereas albumin concentrations did not differ significantly from the corresponding concentrations in control subjects and patients with intra-abdominal abscess. Despite nutritional intervention, albumin synthesis rate is decreased in intestinal fistula patients with intra-abdominal abscess; albumin synthesis returns to control values during convalescence.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Findlay, Rick
The U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Site Office (NNSA/NSO) initiated the Offsites Project to characterize the risk posed to human health and the environment as a result of testing at formerly used nuclear sites in Alaska, Colorado, Mississippi, Nevada, and New Mexico. The scope of this Fluid Management Plan (FMP) is to support the subsurface investigation at the Project Shoal Area (PSA) Corrective Action Unit (CAU) 447, Shoal - Subsurface, Nevada, in accordance with the ''Federal Facility Agreement and Consent Order'' (FFACO) (1996). Corrective Action Unit 447 is located in the Sand Spring Range, southmore » of Highway 50, about 39 miles southeast of Fallon, Nevada. (Figure 1-1). This FMP will be used at the PSA in lieu of an individual discharge permit for each well or a general water pollution control permit for management of all fluids produced during the drilling, construction, development, testing, experimentation, and/or sampling of wells conducted by the Offsites Project. The FMP provides guidance for the management of fluids generated during investigation activities and provides the standards by which fluids may be discharged on site. Although the Nevada Division of Environmental Protection (NDEP), Bureau of Federal Facilities (BoFF) is not a signatory to this FMP, it is involved in the negotiation of the contents of this plan and approves the conditions contained within. The major elements of this FMP include: (1) establishment of a well-site operations strategy; (2) site design/layout; (3) monitoring of contamination indicators (monitoring program); (4) sump characterization (sump sampling program); (5) fluid management decision criteria and fluid disposition; and (6) reporting requirements.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tim Echelard
The U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Site Office (NNSA/NSO) initiated the Offsites Project to characterize the risk posed to human health and the environment as a result of testing at formerly used nuclear sites in Alaska, Colorado, Mississippi, Nevada, and New Mexico. The scope of this Fluid Management Plan (FMP) is to support the subsurface investigation at the Project Shoal Area (PSA) Corrective Action Unit (CAU) 447, Shoal-Subsurface, Nevada, in accordance with the ''Federal Facility Agreement and Consent Order'' (FFACO) (1996). Corrective Action Unit 447 is located in the Sand Spring Range, south of Highwaymore » 50, about 39 miles southeast of Fallon, Nevada. (Figure 1-1). This FMP will be used at the PSA in lieu of an individual discharge permit for each well or a general water pollution control permit for management of all fluids produced during the drilling, construction, development, testing, experimentation, and/or sampling of wells conducted by the Offsites Project. The FMP provides guidance for the management of fluids generated during investigation activities and provides the standards by which fluids may be discharged on site. Although the Nevada Division of Environmental Protection (NDEP), Bureau of Federal Facilities (BoFF) is not a signatory to this FMP, it is involved in the negotiation of the contents of this plan and approves the conditions contained within. The major elements of this FMP include: (1) establishment of a well-site operations strategy; (2) site design/layout; (3) monitoring of contamination indicators (monitoring program); (4) sump characterization (sump sampling program); (5) fluid management decision criteria and fluid disposition; and (6) reporting requirements.« less
Hung, Le Chi; Goggins, Jamie; Fuente, Marta; Foley, Mark
2018-05-14
Design of bearing layers (granular fill material layers) is important for a house with a soil depressurisation (SD) system for indoor radon mitigation. These layers should not only satisfy the bearing capacity and serviceability criteria but should also provide a sufficient degree of the air permeability for the system. Previous studies have shown that a critical parameter for a SD system is the sub-slab pressure field extension in the bearing layers, but this issue has not been systematically investigated. A series of two-dimensional computational fluid dynamic simulations that investigate the behaviour of the sub-slab pressure field extension developed in a SD system is presented in this paper. The SD system considered in this paper consists of a granular fill material layer and a radon sump. The granular fill materials are 'T1 Struc' and 'T2 Perm', which are standard materials for building in the Republic of Ireland. Different conditions, which might be encountered in a practical situation, were examined. The results show that the air permeability and thickness of the granular fill materials are the two key factors which affect the sub slab pressure field extension (SPFE) significantly. Furthermore, the air permeability of native soil is found to be a fundamental factor for the SPFE so that it should be well understood when designing a SD system. Therefore, these factors should be considered sufficiently in each practical situation. Finally, a significant improvement of the pressure field extension can be achieved by ensuring air tightness of the SD system. Copyright © 2018 Elsevier B.V. All rights reserved.
Zhou, Bo; Han, Gang; Chen, Yu; A, Jiye; Gu, Guosheng; Chen, Jun; Wang, Gefei; Li, Jieshou
2014-01-01
Abstract Background: Low serum albumin concentration is a predictor of failure of source control for intra-abdominal infection. However, data on dynamics of albumin synthesis in these patients and to what extent these changes contribute to hypoalbuminemia are relatively scarce. We investigated in a group of patients with gastrointestinal fistula the dynamic response of liver albumin synthesis to intra-abdominal abscess and how these related to hypoalbuminemia and circulating endocrine hormone profiles. Methods: Eight gastrointestinal fistula patients scheduled to undergo percutaneous abscess sump drainage were enrolled prospectively to measure albumin synthesis rates at different stages of the inflammatory response (immediately after diagnosis and 7 d following sump drainage when clinical signs of intra-abdominal sepsis had been eradicated). Eight age-, sex-, and body mass index–matched intestinal fistula patients were studied as control patients. Consecutive arterial blood samples were drawn during a primed-constant infusion (priming dose: 4 micromol·kg−1, infusion rate: 6 micromol·kg−1·min−1) to determine the incorporation rate of L-[ring-2H5]-phenylalanine directly into plasma albumin using gas chromatography/mass spectrometry analysis. Results: Patients suffering from intra-abdominal infection had reduced plasma albumin and total plasma protein concentrations, compared with control patients. Albumin fractional synthesis rates in patients with intra-abdominal abscess were decreased, compared with those in the control group. When the source of infection was removed, albumin synthesis rates returned to control values, whereas albumin concentrations did not differ significantly from the corresponding concentrations in control subjects and patients with intra-abdominal abscess. Conclusion: Despite nutritional intervention, albumin synthesis rate is decreased in intestinal fistula patients with intra-abdominal abscess; albumin synthesis returns to control values during convalescence. PMID:24460539
1984-12-13
8217-- - - -- - - - - - ----- - - - - - - - .101 Clear at Building Clear&Grub @ Bldg. 2000.00 CY .50 1,0(,() Mass Bldg. Excav. 26000.00 CY 2.50 65.00, Grade Beam Excav. 2100.00 CY 4.00...95,112 Sail Investigation Compaction Tests 20.00 EA 150.00 3.000 Perimeter Drainage 2000.00 LF 16.00 32,00 Under Floor Drain LF Clean Walks /Street 1.00 LS...EA4 Equip. Curbs 3500.00 Sf 5.00 17.5:00 -. Grade Beams 7200.00 SF 11.50 82,800 Sumo Pits 1.00 EA 500.00 500 Cooling Tower Sump 600.00 SF 11.50 6,900
1981-03-01
i I.L 08~z oi-z ok oi 06-z oiL oi’L 0#lp t o HH OJO.4... oil sump walls. Oil level is readily discerned through the translucent plastic nose cone. 334 got H ) I aNZ 9j(OL) ’f(OL) =U) I auc90 = U1 UNZ V~dI...o D 00 0 (W0U I LL Z( < U. a) 00 - 4. 210 LU C 337U C W LUV I - z 0- zz D0 CVJ 0< -IL ~ Z 0ui I - fcic zL caz - < - < < <cjj CA00 > I ccn > -/ -L - o
NASA Technical Reports Server (NTRS)
Westerheide, D. E.; Carter, H. G.; Erickson, R. C.; Kerlin, E. E.
1972-01-01
The nuclear heating of the propellant in all of the four baseline RNS configurations studied was much lower than that of the nuclear flight module configuration with the 5000-MW NERVA analyzed previously. Although the nuclear heating has been reduced, the effect of nuclear heating on the propellant as well as the effect of nuclear heating on internal structures such as antivortex baffles, screens, and sump components cannot be neglected. In addition, it was found that the present analytical precedures were not able to predict boundary layer initiation and breakoff points with the accuracy necessary to predict propellant thermodynamic nonequilibrium (stratification) and/or mixing.
Fuels and Lubricants Influence on Turbine Engine Design and Performance
1974-08-01
Temperatures, Mission A. 30 16. Misrion A Interceptor ECS SchemaLiu. 32 17. GEl4/FLiTE-2A Fuel Delivery System Schematic. 34 18. GE14 /FLITE-2A Oil Sump...Layout Drawing. 36 19. G0E4/FL,I’LE-2A LubriaLiui SysLem Schematic. 37 20. GEl4/FLITE-2A Fluid Power System Schematic. 41 21. GE14 /FLITE-2A Fluid Syqtem...Schematic. 1 35 63. GEI4/FI,ITE-2B ThermaL Profiles, MIL-L-27502. 140 64. GE14 /FLIT.-2B Thermal Profiles, 500’ F E’ster. 141 .ix 7 LIST OF ILUWSTRAT LON
Development of high temperature liquid lubricants for low-heat rejection heavy duty diesel engines
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wiczynski, T.A.; Marolewski, T.A.
1993-03-01
Objective was to develop a liquid lubricant that will allow advanced diesel engines to operate at top ring reversal temperatures approaching 500 C and lubricant sump temperatures approaching 250 C. Base stock screening showed that aromatic esters and diesters has the lowest deposit level, compared to polyol esters, poly-alpha-olefins, or refined mineral oil of comparable viscosity. Classical aryl and alkyl ZDP antiwear additives are ineffective in reducing wear with aromatic esters; the phosphate ester was a much better antiwear additive, and polyol esters are more amenable to ZDP treatment. Zeolites and clays were evaluated for filtration.
A novel pulse height analysis technique for nuclear spectroscopic and imaging systems
NASA Astrophysics Data System (ADS)
Tseng, H. H.; Wang, C. Y.; Chou, H. P.
2005-08-01
The proposed pulse height analysis technique is based on the constant and linear relationship between pulse width and pulse height generated from front-end electronics of nuclear spectroscopic and imaging systems. The present technique has successfully implemented into the sump water radiation monitoring system in a nuclear power plant. The radiation monitoring system uses a NaI(Tl) scintillator to detect radioactive nuclides of Radon daughters brought down by rain. The technique is also used for a nuclear medical imaging system. The system uses a position sensitive photomultiplier tube coupled with a scintillator. The proposed techniques has greatly simplified the electronic design and made the system a feasible one for potable applications.
Variable Gravity Effects on the Cooling Performance of a Single Phase Confined Spray
NASA Technical Reports Server (NTRS)
Michalak, Travis; Yerkes, Kirk; Baysinger, Karri; McQuillen, John
2005-01-01
The objective of this paper is to discuss the testing of a spray cooling experiment designed to be flown on NASA's KC-135 Reduced Gravity Testing Platform. Spray cooling is an example of a thermal management technique that may be utilized in high flux heat acquisition and high thermal energy transport concepts. Many researchers have investigated the utility of spray cooling for the thermal management of devices generating high heat fluxes. However, there has been little research addressing the physics and ultimate performance of spray cooling in a variable gravity environment. An experimental package, consisting of a spray chamber coupled to a fluid delivery loop system, was fabricated for variable gravity flight tests. The spray chamber contains two opposing nozzles spraying on target Indium Tin Oxide (ITO) heaters. These heaters are mounted on glass pedestals, which are part of a sump system to remove unconstrained liquid from the test chamber. Liquid is collected in the sumps and returned to the fluid delivery loop. Thermocouples mounted in and around the pedestals are used to determine both the heat loss through the underside of the IT0 heater and the heat extracted by the spray. A series of flight tests were carried out aboard the KC-135, utilizing the ability of the aircraft to produce various gravity conditions. During the flight tests, for a fixed flow rate, heat input was varied at 20, 30, 50, and 80W with variable gravities of 0.01, 0.16, 0.36, and 1.8g. Flight test data was compared to terrestrial baseline data in addition to analytical and numerical solutions to evaluate the heat transfer in the heater and support structure . There were significant differences observed in the spray cooling performance as a result of variable gravity conditions and heat inputs. In general, the Nussult number at the heater surface was found to increase with decreasing gravity conditions for heat loads greater than 30W.
A&M. TAN607. Section views of hot shop. Section E shows ...
A&M. TAN-607. Section views of hot shop. Section E shows equipment areas along rear wall. Section F shows storage pool cut along east/west line. Roof trusses, shelves along sides of pool, drain, roof trusses, shelves along sides of pool, drain, and sump. Section G cuts along north/south to show centerline of turntables, manipulator arms, O-man bridge, crane bridge. Referent drawing is ID-33-E-158 above. Ralph M. Parsons 902-3-ANP-607-A 107. Date: December 1952, but as-built in 1982. Approved by INEEL Classification Office for public release. INEEL index code no. 034-0607-00-693-106759 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
A Parametric Study of Slag Skin Formation in Electroslag Remelting
NASA Astrophysics Data System (ADS)
Yanke, Jeff; Krane, Matthew John M.
In electroslag remelting (ESR), the slag generates heat, chemically refines the melting electrode material, and forms frozen skin on the mold. An axisymmetric model is used to simulate fluid flow, heat transfer, solidification, and electromagnetics and their interaction with slag skin formation in ESR. A volume of fluid (VOF) method is used to track the slag/metal interface, allowing simulation of slag freezing to the mold. Mold diameter and applied current are varied to determine how these parameters affect melt rate and formation of slag skin during ESR. Variations in the slag skin thickness within the slag cap are found to have a significant impact on melt rate and depth of metal sump. Changes in slag cap volume resulted in small changes in melt rate.
Seals/Secondary Fluid Flows Workshop 1997; Volume II: HSR Engine Special Session
NASA Technical Reports Server (NTRS)
Hendricks, Robert C. (Editor)
2006-01-01
The High Speed Civil Transport (HSCT) will be the largest engine ever built and operated at maximum conditions for long periods of time. It is being developed collaboratively with NASA, FAA, Boeing-McDonnell Douglas, Pratt & Whitney, and General Electric. This document provides an initial step toward defining high speed research (HSR) sealing needs. The overview for HSR seals includes defining objectives, summarizing sealing and material requirements, presenting relevant seal cross-sections, and identifying technology needs. Overview presentations are given for the inlet, turbomachinery, combustor and nozzle. The HSCT and HSR seal issues center on durability and efficiency of rotating equipment seals, structural seals and high speed bearing and sump seals. Tighter clearances, propulsion system size and thermal requirements challenge component designers.
NASA Astrophysics Data System (ADS)
Luo, Yajun; Zhang, Zhifeng; Li, Bao; Gao, Mingwei; Qiu, Yang; He, Min
2017-12-01
To obtain a large-sized, high-quality aluminum alloy billet, an advanced uniform direct chill (UDC) casting method was developed by combining annular electromagnetic stirring (A-EMS) with intercooling in the sump. The 7005 alloy was chosen to investigate the effect of UDC on grain refinement and homogeneity during normal direct chill (NDC) casting. It was concluded that the microstructure consisting of both primary α-Al phase and secondary phases becomes finer and more homogeneous for the billets prepared with UDC casting compared to those prepared with NDC casting, and the forced cooling from both the inner and outer melt under A-EMS has a measurable effect on grain refinement and homogeneity.
Risser, Dennis W.
2006-01-01
This report, prepared in cooperation with the Department of Environmental Protection, Office of Mineral Resources Management, provides a preliminary analysis of water budgets and generalized ground-water/surface-water interactions for Bushkill and parts of Monocacy Creek watersheds in Northampton County, Pa., by use of a ground-water flow model. Bushkill Creek watershed was selected for study because it has areas of rapid growth, ground-water withdrawals from a quarry, and proposed stream-channel modifications, all of which have the potential for altering ground-water budgets and the interaction between ground water and streams. Preliminary 2-dimensional, steady-state simulations of ground-water flow by the use of MODFLOW are presented to show the status of work through September 2005 and help guide ongoing data collection in Bushkill Creek watershed. Simulations were conducted for (1) predevelopment conditions, (2) a water table lowered for quarry operations, and (3) anthropogenic changes in hydraulic conductivity of the streambed and aquifer. Preliminary results indicated under predevelopment conditions, the divide between the Bushkill and Monocacy Creek ground-water basins may not have been coincident with the topographic divide and as much as 14 percent of the ground-water discharge to Bushkill Creek may have originated from recharge in the Monocacy Creek watershed. For simulated predevelopment conditions, Schoeneck Creek and parts of Monocacy Creek were dry, but Bushkill Creek was gaining throughout all reaches. Simulated lowering of the deepest quarry sump to an altitude of 147 feet for quarry operations caused ground-water recharge and streamflow leakage to be diverted to the quarry throughout about 14 square miles and caused reaches of Bushkill and Little Bushkill Creeks to change from gaining to losing streams. Lowering the deepest quarry sump to an altitude of 100 feet caused simulated ground-water discharge to the quarry to increase about 4 cubic feet per second. Raising the deepest sump to an altitude of 200 feet caused the simulated discharge to the quarry to decrease about 14 cubic feet per second.Decreasing the hydraulic conductivity of the streambed of Bushkill Creek in the reach of large losses of flow caused simulated ground-water levels to decline and ground-water discharge to a quarry to decrease from 74 to 45 cubic feet per second.Decreasing the hydraulic conductivity of a hypothesized highly transmissive zone with a plug of relatively impermeable material caused ground-water levels to increase east of the plug and decline west of the plug, and decreased the discharge to a quarry from 74 to 53 cubic feet per second. Preliminary results of the study have significant limitations, which need to be recognized by the user. The results demonstrated the usefulness of ground-water modeling with available data sets, but as more data become available through field studies, a more complete evaluation could be conducted of the preliminary assumptions in the conceptual model, model sensitivity, and effects of boundary conditions. Additional streamflow and ground-water-level measurements would be needed to better quantify recharge and aquifer properties, particularly the anisotropy of carbonate rocks. Measurements of streamflow losses at average, steady-state hydrologic conditions could provide a more accurate estimate of ground-water recharge from this source, which directly affects water budgets and contributing areas simulated by the model.
Heterotrophic bacteria in an air-handling system.
Hugenholtz, P; Fuerst, J A
1992-01-01
Heterotrophic bacteria from structural surfaces, drain pan water, and the airstream of a well-maintained air-handling system with no reported building-related illness were enumerated. Visually the system appeared clean, but large populations of bacteria were found on the fin surface of the supply-side cooling coils (10(5) to 10(6) CFU cm-2), in drain pan water (10(5) to 10(7) CFU ml-1), and in the sump water of the evaporative condenser (10(5) CFU ml-1). Representative bacterial colony types recovered from heterotrophic plate count cultures on R2A medium were identified to the genus level. Budding bacteria belonging to the genus Blastobacter dominated the supply surface of the coil fins, the drain pan water, and the postcoil air. These data and independent scanning electron microscopy indicated that a resident population of predominantly Blastobacter bacteria was present as a biofilm on the supply-side cooling coil fins. Images PMID:1476435
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mancini, T.R.; Chaturvedi, L.N.; Gebhard, T.G.
A demonstration project to heat the Senior Citizens Center at Truth or Consequences, New Mexico with geothermal waters is described. There were three phases to the project: Phase I - design and permitting; Phase II - installation of the heating system and well drilling; and Phase III - operation of the system. All three phases went well and there was only one major problem encountered. This was that the well which was drilled to serve as the geothermal source was dry. This could not have been anticipated and there was, as a contingency plan, the option of using an existingmore » sump in the Teen Center adjacent to the Senior Citizens Center as the geothermal source. The system was made operational in August of 1981 and has virtually supplied all of the heat to the Senior Citizens Center during this winter.« less
[Gastroenterology in the G-DRG-System 2004].
Bunzemeier, H; Frühmorgen, P; Caspary, W F; Roeder, N
2003-11-01
After a year of preliminary voluntarily introduction of casemix funding in hospitals in 2003 nearly every German hospital will be confronted with lump sump payments on the basis of the G-DRG system for their inpatient care starting from January 2004. To analyse weaknesses referring to gastroenterology services within the G-DRG version 1.0 the German Association for Disorders of the Digestive System and Metabolism (DGVS) and the DRG-Research-Group from the University of Muenster conducted a DRG evaluation project. In the analysis patient data from 16 hospitals were included. As a result of the project recommendations for G-DRG adjustments were generated. Those recommendations were implemented in the advancement to G-DRG version 2004. Also the International Classification of Diseases (ICD-10) was modified to ICD-10 German Modification. The classification of procedures OPS-301 was revised. The main adjustments to the G-DRG system and both classifications will be presented in this paper.
NASA Astrophysics Data System (ADS)
Zhang, L.; Eskin, D. G.; Miroux, A.; Subroto, T.; Katgerman, L.
2012-07-01
Controlling macrosegregation is one of the major challenges in direct-chill (DC) casting of aluminium alloys. In this paper, the effect of the inlet geometry (which influences the melt distribution) on macrosegregation during the DC casting of 7050 alloy billets was studied experimentally and by using 2D computer modelling. The ALSIM model was used to determine the temperature and flow patterns during DC casting. The results from the computer simulations show that the sump profiles and flow patterns in the billet are strongly influenced by the melt flow distribution determined by the inlet geometry. These observations were correlated to the actual macrosegregation patterns found in the as-cast billets produced by having two different inlet geometries. The macrosegregation analysis presented here may assist in determining the critical parameters to consider for improving the casting of 7XXX aluminium alloys.
Scale Rules for Macrosegregation during Direct-Chill Casting of Aluminum Alloys
NASA Astrophysics Data System (ADS)
Eskin, Dmitry G.; Du, Qiang; Katgerman, Laurens
2008-05-01
An analysis of published experimental and numerical results shows that there is a scaling relationship between the magnitude and direction of centerline segregation in direct-chill (DC) cast billets from aluminum alloys and the process parameters, i.e., billet diameter and casting speed. It seems that there is always a range of these process parameters where the centerline segregation is positive, and there is a threshold when the centerline segregation vanishes. Numerical simulations of macrosegregation during DC casting of a binary Al-Cu alloy were performed at different ratios of casting speed and billet diameter. The macrosegregation model takes into account only two mechanisms of macrosegregation, i.e., thermosolutal convection and shrinkage-induced flow. The results of these computer simulations fit well to the dependence obtained using numerous reference data. The results are discussed in terms of the contribution of different mechanisms of macrosegregation and the shape of the billet sump.
Determination of the oil distribution in a hermetic compressor using numerical simulation
NASA Astrophysics Data System (ADS)
Posch, S.; Hopfgartner, J.; Berger, E.; Zuber, B.; Almbauer, R.; Schöllauf, P.
2017-08-01
In addition to the reduction of friction the oil in a hermetic compressor is very important for the transfer of heat from hot parts to the compressor shell. The simulation of the oil distribution in a hermetic reciprocating compressor for refrigeration application is shown in the present work. Using the commercial Computational Fluid Dynamics (CFD) software ANSYS Fluent, the oil flow inside the compressor shell from the oil pump outlet to the oil sump is calculated. A comprehensive overview of the used models and the boundary conditions is given. After reaching steady-state conditions the oil covered surfaces are analysed concerning heat transfer coefficients. The gained heat transfer coefficients are used as input parameters for a thermal model of a hermetic compressor. An increase in accuracy of the thermal model with the simulated heat transfer coefficients compared to values from literature is shown by model validation with experimental data.
Heterotrophic bacteria in an air-handling system.
Hugenholtz, P; Fuerst, J A
1992-12-01
Heterotrophic bacteria from structural surfaces, drain pan water, and the airstream of a well-maintained air-handling system with no reported building-related illness were enumerated. Visually the system appeared clean, but large populations of bacteria were found on the fin surface of the supply-side cooling coils (10(5) to 10(6) CFU cm-2), in drain pan water (10(5) to 10(7) CFU ml-1), and in the sump water of the evaporative condenser (10(5) CFU ml-1). Representative bacterial colony types recovered from heterotrophic plate count cultures on R2A medium were identified to the genus level. Budding bacteria belonging to the genus Blastobacter dominated the supply surface of the coil fins, the drain pan water, and the postcoil air. These data and independent scanning electron microscopy indicated that a resident population of predominantly Blastobacter bacteria was present as a biofilm on the supply-side cooling coil fins.
Oil spills, 1971-75, Gulf of Mexico outer continental shelf
Danenberger, Elmer P.
1976-01-01
Oil spillage connected with federally supervised drilling and production activities has been a matter of wide public concern. In its supervision of mineral-resource development on the Outer Continental Shelf (OCS), the U.S. Geological Survey is responsible for the day-to-day inspection and monitoring of OCS oil and gas operations. During these activities, the U.S. Geological Survey records and investigates hydrocarbon discharges resulting from such operations. Beginning in 1971, all spills have been recorded, and a computer file has been maintained on all spills of 1 barrel or more. The total Gulf of Mexico OCS oil spillage recorded during January 1, 1971-December 31, 1975, amounted to 51,421 barrels. Production during that period amounted to 35,219 barrels per barrel spilled. In all, 5,857 spills were recorded, but 85.5 percent of the total spill volume was contributed by just 5 incidents. The environmental effect of these incidents apparently was minimal and of short duration. No spills of more than 50 barrels resulted from drilling operations during the period. The only spillage resulting from blowouts was caused by nondrilling incidents, including completion, production, and workover. The amount of oil discharged from spills of less than 50 barrels decreased by more than half between 1971 and 1975. The improvement reflects changes in the operating philosophy of the offshore industry, tightening of U.S. Geological Survey operating orders, and substantial increases in the inspection force. Most production-platform spills involve failures in the sump system, the separator system, or other hydrocarbon-handling equipment; improved sump-system designs and better high-low-level controls have reduced both the number and the volume of spills. Pipeline and pump spills also declined significantly, although the decline appears less attributable to revisions in OCS operating requirements. No operator consistently contributed a disproportionate amount of spillage. Most of the platforms having production spills had only one spill during the period. Of the 304 platforms having incidents, 255 had 2 spills or less and 188 had only 1 spill. Comparison of the volume spilled with the volume produced for Gulf of Mexico OCS operations during 1971-75 results in a spillage rate of 0.0028 percent. Spillage from tankers is estimated to be greater. The OCS drilling and production spillage rate is not expected to increase during exploration and development of the frontier areas.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Justice, J.C.; Delli-Gatti, F.A.
1985-12-03
A mining machine is utilized for making original generally horizontal bores in coal seams, and for enlarging preexisting bores. A single cutting head is mounted for rotation about a first horizontal axis generally perpendicular to the dimension of elongation of the horizontal bore, and is pivotal about a second horizontal axis, parallel to the first axis, to change its cutting, vertical position within the bore. A non-rotatable body member, with side wall supports, is mounted posteriorly of the cutting head, and includes a conveyor mechanism and a power mechanism operatively connected to it. The machine can be sumped into amore » bore and then the cutting head rotated about the second axis to change the vertical position thereof, and then moved rearwardly, any cut material being continuously conveyed to the bore mouth by the conveyor mechanism. The amount of vertical movement during the pivoting action about the second axis is controlled in response to the automatic sensing of the thickness of the coal seam in which the machine operates.« less
System design description of forced-convection molten-salt corrosion loops MSR-FCL-3 and MSR-FCL-4
DOE Office of Scientific and Technical Information (OSTI.GOV)
Huntley, W.R.; Silverman, M.D.
1976-11-01
Molten-salt corrosion loops MSR-FCL-3 and MSR-FCL-4 are high-temperature test facilities designed to evaluate corrosion and mass transfer of modified Hastelloy N alloys for future use in Molten-Salt Breeder Reactors. Salt is circulated by a centrifugal sump pump to evaluate material compatibility with LiF-BeF/sub 2/-ThF/sub 4/-UF/sub 4/ fuel salt at velocities up to 6 m/s (20 fps) and at salt temperatures from 566 to 705/sup 0/C (1050 to 1300/sup 0/F). The report presents the design description of the various components and systems that make up each corrosion facility, such as the salt pump, corrosion specimens, salt piping, main heaters, salt coolers,more » salt sampling equipment, and helium cover-gas system, etc. The electrical systems and instrumentation and controls are described, and operational procedures, system limitations, and maintenance philosophy are discussed.« less
Prudic, David E.
1978-01-01
A low-level radioactive-waste burial site, West Valley, N.Y., operated from 1963 to 1975, contains 12 refuse-filled trenches about 20 feet deep in till. Twenty-eight wells, 1.25 inch in diameter, were driven to selected depths in 11 of the 12 trenches to obtain gas and water samples for chemical and radiochemical analysis, water-level measurements for evaluation of trench-cover permeability. Gas from unsaturated refuse above the trench water level was detected in nearly all wells. Rapid water-level response in most wells to pumping of water from trench sumps 20 to 275 feet distant showed the refuse to be highly permeable. Described in detail are the methods and equipment used to (1) install the wells, (2) collect gas and water samples, and (3) monitor radiation and methane concentrations while driving wells into trenches. A record of each well driven into the burial trenches is included. (Woodard-USGS)
The effectiveness of radon preventive and remedial measures in Irish homes.
Long, S; Fenton, D; Cremin, M; Morgan, A
2013-03-01
It is estimated that approximately 100 000 Irish homes have radon concentrations above the reference level of 200 Bq m(-3). To minimise the number of new homes with this problem, building regulations require that all new homes built since July 1998 in high radon areas are installed with radon barriers during construction. Measurements on local authority homes in a number of high radon areas have allowed the impact of these new regulations to be assessed. In County Cork a reduction of up to 70% in the mean radon concentration was observed in homes built since 1998 relative to those built before this date. A reduction in both the number of homes exceeding the reference level and the maximum concentration measured in homes was also measured. Homes exceeding the reference level were remediated with the use of an active sump. The results of this remedial work are also presented and show that the mean reduction in radon concentration achieved was 92%.
Estimating zero-g flow rates in open channels having capillary pumping vanes
NASA Astrophysics Data System (ADS)
Srinivasan, Radhakrishnan
2003-02-01
In vane-type surface tension propellant management devices (PMD) commonly used in satellite fuel tanks, the propellant is transported along guiding vanes from a reservoir at the inlet of the device to a sump at the outlet from where it is pumped to the satellite engine. The pressure gradient driving this free-surface flow under zero-gravity (zero-g) conditions is generated by surface tension and is related to the differential curvatures of the propellant-gas interface at the inlet and outlet of the PMD. A new semi-analytical procedure is prescribed for accurately calculating the extremely small fuel flow rates under reasonably idealized conditions. Convergence of the algorithm is demonstrated by detailed numerical calculations. Owing to the substantial cost and the technical hurdles involved in accurately estimating these minuscule flow rates by either direct numerical simulation or by experimental methods which simulate zero-g conditions in the lab, it is expected that the proposed method will be an indispensable tool in the design and operation of satellite fuel tanks.
Hydraulic actuator for an electric circuit breaker
Imam, I.
1983-05-17
This actuator comprises a fluid motor having a piston, a breaker-opening space at one side of the piston, and a breaker-closing space at its opposite side. An accumulator freely communicates with the breaker-opening space for supplying pressurized fluid thereto during a circuit breaker opening operation. The breaker-opening space and the breaker-closing space are connected by an impeded flow passage. A pilot valve opens to allow the pressurized liquid in the breaker-closing space to flow to a back chamber of a normally closed main valve to cause the main valve to be opened during a circuit breaker opening operation to release the pressurized liquid from the breaker-closing space. An impeded passage affords communication between the back chamber and a sump located on the opposite side of the main valve from the back chamber. The pilot valve and impeded passage allow rapid opening of the main valve with pressurized liquid from the breaker closing side of the piston. 3 figs.
Hydraulic actuator for an electric circuit breaker
Imam, Imdad [Colonie, NY
1983-01-01
This actuator comprises a fluid motor having a piston, a breaker-opening space at one side of the piston, and a breaker-closing space at its opposite side. An accumulator freely communicates with the breaker-opening space for supplying pressurized fluid thereto during a circuit breaker opening operation. The breaker-opening space and the breaker-closing space are connected by an impeded flow passage. A pilot valve opens to allow the pressurized liquid in the breaker-closing space to flow to a back chamber of a normally closed main valve to cause the main valve to be opened during a circuit breaker opening operation to release the pressurized liquid from the breaker-closing space. An impeded passage affords communication between the back chamber and a sump located on the opposite side of the main valve from the back chamber. The pilot valve and impeded passage allow rapid opening of the main valve with pressurized liquid from the breaker closing side of the piston.
High explosive spot test analyses of samples from Operable Unit (OU) 1111
DOE Office of Scientific and Technical Information (OSTI.GOV)
McRae, D.; Haywood, W.; Powell, J.
1995-01-01
A preliminary evaluation has been completed of environmental contaminants at selected sites within the Group DX-10 (formally Group M-7) area. Soil samples taken from specific locations at this detonator facility were analyzed for harmful metals and screened for explosives. A sanitary outflow, a burn pit, a pentaerythritol tetranitrate (PETN) production outflow field, an active firing chamber, an inactive firing chamber, and a leach field were sampled. Energy dispersive x-ray fluorescence (EDXRF) was used to obtain semi-quantitative concentrations of metals in the soil. Two field spot-test kits for explosives were used to assess the presence of energetic materials in the soilmore » and in items found at the areas tested. PETN is the major explosive in detonators manufactured and destroyed at Los Alamos. No measurable amounts of PETN or other explosives were detected in the soil, but items taken from the burn area and a high-energy explosive (HE)/chemical sump were contaminated. The concentrations of lead, mercury, and uranium are given.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
AFP no. 28 (General Electric Lynn Manufacturing dept). is located in the City of Everett, Mass. The facility is composed of 10 buildings having 344,342 square feet of floor space on a 43-acre tract. The plant is engaged in the manufacture of large jet engine components and sub-assemblies. AFT 29 (General Electric River Works Facility) is located in the City of Lynn, Mass. AFT No. 29 is part of the General Electric Aircraft Engine Business Group and the facilities are used for testing and assembly of jet engines. The following conclusions have been developed based on the results of themore » project team's field inspection, review of plant records and files, and interviews with plant personnel. Each of the sites listed below was ranked using the HARM system and was determined to have a sufficient potential for environmental contamination to warrant some degree of follow-on investigation. AFB no. 28: Waste sump and chip storage area; and AFT no. 29: Underground fuel line leaks and underground fuel storage tank leak.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Becthel Jacobs Company LLC
2002-11-01
The Y-12 National Security Complex (Y-12 Complex) is an active manufacturing and developmental engineering facility that is located on the U.S. Department of Energy (DOE) Oak Ridge Reservation. Building 9201-2 was one of the first process buildings constructed at the Y-12 Complex. Construction involved relocating and straightening of the Upper East Fork Poplar Creek (UEFPC) channel, adding large quantities of fill material to level areas along the creek, and pumping of concrete into sinkholes and solution cavities present within the limestone bedrock. Flow from a large natural spring designated as ''Big Spring'' on the original 1943 Stone & Webster Buildingmore » 9201-2 Field Sketch FS6003 was captured and directed to UEFPC through a drainpipe designated Outfall 51. The building was used from 1953 to 1955 for pilot plant operations for an industrial process that involved the use of large quantities of elemental mercury. Past operations at the Y-12 Complex led to the release of mercury to the environment. Significant environmental media at the site were contaminated by accidental releases of mercury from the building process facilities piping and sumps associated with Y-12 Complex mercury handling facilities. Releases to the soil surrounding the buildings have resulted in significant levels of mercury in these areas of contamination, which is ultimately transported to UEFPC, its streambed, and off-site. Bechtel Jacobs Company LLC (BJC) is the DOE-Oak Ridge Operations prime contractor responsible for conducting environmental restoration activities at the Y-12 Complex. In order to mitigate the mercury being released to UEFPC, the Big Spring Water Treatment System will be designed and constructed as a Comprehensive Environmental Response, Compensation, and Liability Act action. This facility will treat the combined flow from Big Spring feeding Outfall 51 and the inflow now being processed at the East End Mercury Treatment System (EEMTS). Both discharge to UEFPC adjacent to Bldg. 9201-2. The EEMTS treats mercury-contaminated groundwater that collects in sumps in the basement of Bldg. 9201-2. A pre-design study was performed to investigate the applicability of various treatment technologies for reducing mercury discharges at Outfall 51 in support of the design of the Big Spring Water Treatment System. This document evaluates the results of the pre-design study for selection of the mercury removal technology for the treatment system.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tremaine, Diana; Douglas, Steven G.
2012-07-01
The Y-12 National Security Complex in Oak Ridge, TN has faced an ongoing challenge from mercury entrapped in soils beneath and adjacent to buildings, storm sewers, and process pipelines. Previous actions to reduce the quantity and/or mobilization of mercury-contaminated media have included plugging of building floor drains, cleaning of sediment and sludge from sumps, manholes, drain lines, and storm sewers, lining/relining of storm sewers and replacement of a portion of the storm sewer trunk line, re-routing and removal of process piping, and installation of the Central Mercury Treatment System to capture and treat contaminated sump water. Despite the success ofmore » these actions, mercury flux in the storm sewer out-falls that discharge to Upper East Fork Poplar Creek (UEFPC) continues to pose a threat to long-term water quality. A video camera survey of the storm sewer network revealed several sections of storm sewer that had large cracks, separations, swells, and accumulations of sediment/sludge and debris. The selected remedy was to clean and line the sections of storm sewer pipe that were determined to be primary contributors to the mercury flux in the storm sewer out-falls. The project, referred to as the West End Mercury Area (WEMA) Storm Sewer Remediation Project, included cleaning sediment and debris from over 2,460 meters of storm sewer pipe followed by the installation of nearly 366 meters of cure-in-place pipe (CIPP) liner. One of the greatest challenges to the success of this project was the high cost of disposal associated with the mercury-contaminated sludge and wastewater generated from the storm sewer cleaning process. A contractor designed and operated an on-site wastewater pre-treatment system that successfully reduced mercury levels in 191 cubic meters of sludge to levels that allowed it to be disposed at Nevada Nuclear Security Site (NNSS) disposal cell as a non-hazardous, low-level waste. The system was also effective at pre-treating over 1,514,000 liters of wastewater to levels that met the waste acceptance criteria for the on-site West End [wastewater] Treatment Facility (WETF). This paper describes the storm sewer cleaning and lining process and the methods used to process the mercury-contaminated sludge and wastewater, as well as several 'lessons learned' that would be relevant to any future projects involving storm sewer cleaning and debris remediation. (authors)« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
BECHTEL NEVADA; U.S. DEPARTMENT OF ENERGY, NATIONAL NUCLEAR SECURITY ADMINISTRATION NEVADA SITE OFFICE
2005-08-01
Corrective Action Unit (CAU) 516, Septic Systems and Discharge Points, is listed in the ''Federal Facility Agreement and Consent Order'' (FFACO) of 1996 (FFACO, 1996). CAU 516 consists of six Corrective Action Sites (CASs) located in Areas 3, 6, and 22 of the Nevada Test Site (NTS), which is located approximately 65 miles northwest of Las Vegas, Nevada (Figure 1). CAU 516 is comprised of the following six CASs: (1) 03-59-01 Building 3C-36 Septic System; (2) 03-59-02 Building 3C-45 Septic System; (3) 06-51-01 Sump and Piping; (4) 06-51-02 Clay Pipe and Debris; (5) 06-51-03 Clean-Out Box and Piping; and (6)more » 22-19-04 Vehicle Decontamination Area. Details on site history and site characterization results for CAU 516 are provided in the approved Corrective Action Investigation Plan (CAIP), (U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office [NNSA/NSO], 2003), and the approved Corrective Action Decision Document (CADD) (NNSA/NSO, 2004).« less
Intelligent Engine Systems: Bearing System
NASA Technical Reports Server (NTRS)
Singh, Arnant P.
2008-01-01
The overall requirements necessary for sensing bearing distress and the related criteria to select a particular rotating sensor were established during the phase I. The current phase II efforts performed studies to evaluate the Robustness and Durability Enhancement of the rotating sensors, and to design, and develop the Built-in Telemetry System concepts for an aircraft engine differential sump. A generic test vehicle that can test the proposed bearing diagnostic system was designed, developed, and built. The Timken Company, who also assisted with testing the GE concept of using rotating sensors for the differential bearing diagnostics during previous phase, was selected as a subcontractor to assist General Electric (GE) for the design, and procurement of the test vehicle. A purchase order was prepared to define the different sub-tasks, and deliverables for this task. The University of Akron was selected to provide the necessary support for installing, and integrating the test vehicle with their newly designed test facility capable of simulating the operating environment for the planned testing. The planned testing with good and damaged bearings will be on hold pending further continuation of this effort during next phase.
Minimization of corrosion using activated sodium bromide in a medium-size cooling tower
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nalepa, C.J.; Moore, R.M.; Golson, G.L.
1996-07-01
The cooling tower at the Albermarle Process Development Center in Baton Rouge, Louisiana, historically used chlorine as a biocide in combination with phosphorus-based corrosion/scale inhibitors. Although this regimen provided biocontrol, sludge and iron buildup was a problem in low-velocity, small cross-sectional areas of piping. A general cleanup of the system was performed in April 1995. This cleanup was followed with a switch to a two-component corrosion inhibitor/dispersant package. Alternate biocides were evaluated at this time. Activated sodium bromide was found to be particularly effective in this tower, which operates at pH {approximately}8.4. Relative to chlorine, the use of activated sodiummore » bromide led to a decrease in general and pitting corrosion on mild steel. The reduced corrosion appears to be due to a combination of both chemical (less attack on passivated metal surfaces) and biological factors (better control of heterotrophic and sessile bacteria). These conclusions are supported by chemical analyses, corrosion meter and coupon data, dip slides, biological activity reaction tests, and visual observations of the tower sump and heat exchanger surfaces.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hoyt, K.R.; Pavelek, M.D. II
1987-01-01
Following the accident at Three Mile Island Unit 2 (TMI-2) substantial areas in the auxiliary and fuel-handling buildings were contaminated. Overflowing sumps backed up floor drains and contaminated a substantial portion of the 282-ft elevation floor. In addition, contamination was spread into the overheads when the nitrogen purge system, which had become internally contaminated, was relieved of overpressure. Operating experience with the Kelly Decontamination System has been exceptional. The system has been defined as a tool of the trade for labor personnel to operate as part of their duties. A detailed training program was provided by the Kelly Division ofmore » Container Products Corporation for the engineers who then trained labor personnel in the operation of the equipment. There were very few problems with personnel on the equipment for routine decontamination operations. The Kelly Decontamination System has proven to be a dose and cost-effective alternative to hands-on decontamination techniques at TMI-2 and should have wide application for large-scale decontamination operations.« less
Management of pancreatic trauma.
Jones, R C
1978-01-01
Since 1950, 300 patients sustaining pancreatic injuries have been managed. Three-fourths of the injuries were due to penetrating trauma with a 20% mortality and one-fourth due to blunt trauma resulting in an 18% mortality. The pancreatic injury was responsible for death in only 3% of patients. Early onset of shock resulted in 38% mortality whereas only 4% of normotensive patients died. No patient died of an isolated pancreatic injury. Sepsis was the second most common cause of death following hemorrhage. Preoperative serum amylase was elevated more frequently following blunt trauma than penetrating trauma, but did not correlate with injury. There has been a tendency toward more frequent use of distal pancreatectomy for simple penetrating injuries without obvious ductal violation which increases operative time, blood loss and possible intra-abdominal abscess since resection usually requires splenectomy. Patients considered for an 80% distal resection are better managed with a Roux-en-Y limb to the distal pancreas since three patients developed diabetes following an 80% or greater resection. A conservative approach consisting of Penrose and sump drainage is adequate for most injuries. PMID:646495
Mercury Reduction and Removal from High Level Waste at the Defense Waste Processing Facility - 12511
DOE Office of Scientific and Technical Information (OSTI.GOV)
Behrouzi, Aria; Zamecnik, Jack
2012-07-01
The Defense Waste Processing Facility processes legacy nuclear waste generated at the Savannah River Site during production of enriched uranium and plutonium required by the Cold War. The nuclear waste is first treated via a complex sequence of controlled chemical reactions and then vitrified into a borosilicate glass form and poured into stainless steel canisters. Converting the nuclear waste into borosilicate glass is a safe, effective way to reduce the volume of the waste and stabilize the radionuclides. One of the constituents in the nuclear waste is mercury, which is present because it served as a catalyst in the dissolutionmore » of uranium-aluminum alloy fuel rods. At high temperatures mercury is corrosive to off-gas equipment, this poses a major challenge to the overall vitrification process in separating mercury from the waste stream prior to feeding the high temperature melter. Mercury is currently removed during the chemical process via formic acid reduction followed by steam stripping, which allows elemental mercury to be evaporated with the water vapor generated during boiling. The vapors are then condensed and sent to a hold tank where mercury coalesces and is recovered in the tank's sump via gravity settling. Next, mercury is transferred from the tank sump to a purification cell where it is washed with water and nitric acid and removed from the facility. Throughout the chemical processing cell, compounds of mercury exist in the sludge, condensate, and off-gas; all of which present unique challenges. Mercury removal from sludge waste being fed to the DWPF melter is required to avoid exhausting it to the environment or any negative impacts to the Melter Off-Gas system. The mercury concentration must be reduced to a level of 0.8 wt% or less before being introduced to the melter. Even though this is being successfully accomplished, the material balances accounting for incoming and collected mercury are not equal. In addition, mercury has not been effectively purified and collected in the Mercury Purification Cell (MPC) since 2008. A significant cleaning campaign aims to bring the MPC back up to facility housekeeping standards. Two significant investigations are being undertaken to restore mercury collection. The SMECT mercury pump has been removed from the tank and will be functionally tested. Also, research is being conducted by the Savannah River National Laboratory to determine the effects of antifoam addition on the behavior of mercury. These path forward items will help us better understand what is occurring in the mercury collection system and ultimately lead to an improved DWPF production rate and mercury recovery rate. (authors)« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Abitz, R.; Jackson, D.; Eddy-Dilek, C.
2011-06-27
The U.S. Department of Energy (DOE) is currently evaluating the water management procedures at the Separations Process Research Unit (SPRU). The facility has three issues related to water management that require technical assistance: (1) due to a excessive rainfall event in October, 2010, contaminated water collected in basements of G2 and H2 buildings. As a result of this event, the contractor has had to collect and dispose of water offsite; (2) The failure of a sump pump at a KAPL outfall resulted in a Notice of Violation issued by the New York State Department of Environment and Conservation (NYSDEC) andmore » subsequent Consent Order. On-site water now requires treatment and off-site disposition; and (3) stormwater infiltration has resulted in Strontium-90 levels discharged to the storm drains that exceed NR standards. The contractor has indicated that water management at SPRU requires major staff resources (at least 50 persons). The purpose of this review is to determine if the contractor's technical approach warrants the large number of staff resources and to ensure that the technical approach is compliant and in accordance with federal, state and NR requirements.« less
Oil strategies benefits over different driving cycles using numerical simulation
NASA Astrophysics Data System (ADS)
Sara, Hanna; Chalet, David; Cormerais, Mickaël; Hetet, Jean-François
2017-08-01
95 g/km is the allowed quantity of CO2 emission normalized to NEDC to be set in 2020. In addition, NEDC will be replaced by more severe driving cycles and will be united worldwide. To respond to those criteria, automotive industries are working on every possible field. Thermal management has been proved to be effective in reducing fuel consumption. Cold start is a primordial reason of overconsumption, as the engine highest efficiency is at its optimal temperature. At cold start, the engine's oil is at its lowest temperature and thus its higher viscosity level. A high viscosity oil generates more friction, which is one of the most important heat losses in the engine. In this paper, hot oil storage is studied. Numerical simulations on GT-suite model were done. The model consists of a 4-cylinder turbocharged Diesel engine using a storage volume of 1 liter of hot oil. Ambient temperature variation were taken into consideration as well as different driving cycles. Furthermore, different configurations of the thermal strategy (multifunction oil sump) were proposed and evaluated. Lubricant temperature and viscosity profiles are presented in the article as well as fuel consumption savings for different configurations, driving cycles and ambient temperatures.
NASA Astrophysics Data System (ADS)
Ola, Max; Thomas, Christiane; Hesse, Ullrich
2017-08-01
Compressor performance test procedures are defined by the standard DIN EN 13771, wherein a variety of possible calorimeter and flow rate measurement methods are suggested. One option is the selection of two independent measurement methods. The accuracies of both selected measurement methods are essential. The second option requires only one method. However the measurement accuracy of the used device has to be verified and recalibrated on a regular basis. The compressor performance test facility at the Technische Universitaet Dresden uses a calibrated flow measurement sensor, a hot gas bypass and a mixed flow heat exchanger. The test bench can easily be modified for tests of various compressor types at different operating ranges and with various refrigerants. In addition, the modified test setup enables the investigation of long term liquid slug and its effects on the compressor. The modification comprises observational components, adjustments of the control system, safety measures and a customized oil recirculation system for compressors which do not contain an integrated oil sump or oil level regulation system. This paper describes the setup of the test bench, its functional principle, the key modifications, first test results and an evaluation of the energy balance.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
As part of the Hanford Federal Facility Agreement and Consent Order negotiations (Ecology et al. 1994), the US Department of Energy, Richland Operations Office, the US Environmental Protection Agency, and the Washington State Department of Ecology agreed that liquid effluent discharges to the ground on the Hanford Site which affect groundwater or have the potential to affect ground would be subject to permitting under the structure of Chapter 173-216 (or 173-218 where applicable) of the Washington Administrative Code, the State Waste Discharge Permit Program. As a result of this decision, the Washington State Department of Ecology and the US Departmentmore » of Energy, Richland Operations Office entered into Consent Order No. DE 91NM-177, (Ecology and DOE-RL 1991). The Consent Order No. DE 91NM-177 requires a series of permitting activities for liquid effluent discharges. This document presents the State Waste Discharge Permit (SWDP) application for the 200-E Chemical Drain Field. Waste water from the 272-E Building enters the process sewer line directly through a floor drain, while waste water from the 2703-E Building is collected in two floor drains, (north and south) that act as sumps and are discharged periodically. The 272-E and 2703-E Buildings constitute the only discharges to the process sewer line and the 200-E Chemical Drain Field.« less
Integrated, flexible, and rapid geophysical surveying
NASA Astrophysics Data System (ADS)
Miller, S. F.; McGinnis, L. D.; Thompson, M. D.; Tome, C.
Aberdeen Proving Ground (APG) is currently managing a comprehensive Installation Restoration Program involving more than 360 solid-waste managing units contained within 13 study areas. The Edgewood area and two landfills in the Aberdeen area appear on the National Priority List under the Comprehensive Environmental Response, Compensation, and Liability Act. Therefore, APG has entered into an interagency agreement with the US Environmental Protection Agency to address the listed areas. The West Branch of the Canal Creek area, located within the Edgewood area, is one of the areas that requires a Source Definition Study because there is an ongoing release of volatile organic compounds into the creek. A report prepared in 1989 included a list of 29 potentially contaminated buildings in the Edgewood area. Sixteen of the buildings contain known contaminants, nine buildings contain unknown contaminants, and four of the buildings are potentially clean. The EAI report recommended that a sampling and monitoring program be established to verify contamination levels in and around each building. Thirteen of the potentially contaminated buildings are in the West Branch of the Canal Creek area and are potential sources of volatile organic compounds. Operations have ceased, and the buildings have been abandoned, but processing equipment, sumps, drains, ventilation systems, and underground storage tanks remain. These appurtenances may contain liquid, solid, or vapor contaminants of unknown nature.
Closure Report for Corrective Action Unit 340: NTS Pesticide Release Sites Nevada Test Site, Nevada
DOE Office of Scientific and Technical Information (OSTI.GOV)
C. M. Obi
The purpose of this report is to provide documentation of the completed corrective action and to provide data confirming the corrective action. The corrective action was performed in accordance with the approved Corrective Action Plan (CAP) (U.S. Department of Energy [DOE], 1999) and consisted of clean closure by excavation and disposal. The Area 15 Quonset Hut 15-11 was formerly used for storage of farm supplies including pesticides, herbicides, and fertilizers. The Area 23 Quonset Hut 800 was formerly used to clean pesticide and herbicide equipment. Steam-cleaning rinsate and sink drainage occasionally overflowed a sump into adjoining drainage ditches. One ditchmore » flows south and is referred to as the quonset hut ditch. The other ditch flows southeast and is referred to as the inner drainage ditch. The Area 23 Skid Huts were formerly used for storing and mixing pesticide and herbicide solutions. Excess solutions were released directly to the ground near the skid huts. The skid huts were moved to a nearby location prior to the site characterization performed in 1998 and reported in the Corrective Action Decision Document (CADD) (DOE, 1998). The vicinity and site plans of the Area 23 sites are shown in Figures 2 and 3, respectively.« less
Design and testing of a mesocosm-scale habitat for culturing the endangered Devils Hole Pupfish
Feuerbacher, Olin; Bonar, Scott A.; Barrett, Paul J.
2016-01-01
aptive propagation of desert spring fishes, whether for conservation or research, is often difficult, given the unique and often challenging environments these fish utilize in nature. High temperatures, low dissolved oxygen, minimal water flow, and highly variable lighting are some conditions a researcher might need to recreate to simulate their natural environments. Here we describe a mesocosm-scale habitat created to maintain hybrid Devils Hole × Ash Meadows Amargosa Pupfish (Cyprinodon diabolis × C. nevadensis mionectes) under conditions similar to those found in Devils Hole, Nevada. This 13,000-L system utilized flow control and natural processes to maintain these conditions rather than utilizing complex and expensive automation. We designed a rotating solar collector to control natural sunlight, a biological reactor to consume oxygen while buffering water quality, and a reverse-daylight photosynthesis sump system to stabilize nighttime pH and swings in dissolved oxygen levels. This system successfully controlled many desired parameters and helped inform development of a larger, more permanent desert fish conservation facility at the U.S. Fish and Wildlife Service’s Ash Meadows National Wildlife Refuge, Nevada. For others who need to raise fish from unique habitats, many components of the scalable and modular design of this system can be adapted at reasonable cost.
Case study: Minimization of corrosion using activated sodium bromide in a medium-size cooling tower
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nalepa, C.J.; Moore, R.M.; Golson, G.L.
1996-10-01
The process loop cooling tower at the Albemarle Process Development Center in Baton Rouge, LA has historically used chlorine as the biocide together with industry accepted phosphorus-based corrosion/scale inhibitors. Although this regimen provided biocontrol, sludge and iron build-up was a recurring problem, especially in low-velocity, small cross-sectional areas of piping. A general clean-up of the system was performed in April, 1995. This clean-up was followed with a switch to a two-component corrosion inhibitor/dispersant package. It was decided to study alternate biocides as well at this time. Activated sodium bromide was found to be particularly effective in this tower, which operatesmore » at pH {approximately}8.4. Relative to chlorine, the use of activated sodium bromide led to a decrease in general and pitting corrosion on mild steel while maintaining prior performance on admiralty brass. The reduced corrosion appears to be due to a combination of both chemical (less attack on passivated metal surfaces) and biological factors (better control of heterotrophic and sessile bacteria). These conclusions are supported by chemical analyses, corrosion meter and coupon data, dip slides, BART (biological activity reaction test) tests, and visual observations of the tower sump and heat exchanger surfaces.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Behrends, L.L.; Bailey, E.; Bulls, M.J.
1996-05-01
Growth and biomass accumulation of selected nutrients and trace metals were monitored for six species of aquatic macrophytes during June, August and November, 1993. Plant species were cultivated in two polyculture treatments, each replicated three times. Polyculture I consisted of Scirpus acutus (hardstem bullrush), Phragmites communes (common reed), and Phalaris arundinacea (canary grass). Polyculture H consisted of Typha spp. (cattail), Scirpus atrovirens (green bullrush), and Scirpus cyperinus (wool grass). Each of the six cells (6 x 9 x 0.6 m), was operated as a gravel-substrate, subsurface-flow wetlands in a continuous recirculating mode. At six week intervals, macro, micro and tracemore » elements were dissolved and added to the sump of the recirculating system. On each of three sampling dates, replicate shoot and root samples were collected, segregated by species and tissue type (roots, rhizomes, stems and leaves), and prepared for gravimetric biomass estimates and chemical analysis. Tissue specific concentrations of N, P, K, Ca, Mg, Fe, Mn, Zn and Cu, were determined on each date for each species and tissue type. Results will be discussed with respect to species specific growth rates, biomass accumulation, and seasonal uptake and translocation of plant nutrients.« less
Characterization of microbial contamination in United States Air Force aviation fuel tanks.
Rauch, Michelle E; Graef, Harold W; Rozenzhak, Sophie M; Jones, Sharon E; Bleckmann, Charles A; Kruger, Randell L; Naik, Rajesh R; Stone, Morley O
2006-01-01
Bacteria and fungi, isolated from United States Air Force (USAF) aviation fuel samples, were identified by gas chromatograph fatty acid methyl ester (GC-FAME) profiling and 16S or 18S rRNA gene sequencing. Thirty-six samples from 11 geographically separated USAF bases were collected. At each base, an above-ground storage tank, a refueling truck, and an aircraft wing tank were sampled at the lowest sample point, or sump, to investigate microbial diversity and dispersion within the fuel distribution chain. Twelve genera, including four Bacillus species and two Staphylococcus species, were isolated and identified. Bacillus licheniformis, the most prevalent organism isolated, was found at seven of the 11 bases. Of the organisms identified, Bacillus sp., Micrococcus luteus, Sphinogmonas sp., Staphylococcus sp., and the fungus Aureobasidium pullulans have previously been isolated from aviation fuel samples. The bacteria Pantoea ananatis, Arthrobacter sp., Alcaligenes sp., Kocuria rhizophilia, Leucobacter komagatae, Dietza sp., and the fungus Discophaerina fagi have not been previously reported in USAF aviation fuel. Only at two bases were the same organisms isolated from all three sample points in the fuel supply distribution chain. Isolation of previously undocumented organisms suggests either, changes in aviation fuel microbial community in response to changes in aviation fuel composition, additives and biocide use, or simply, improvements in isolation and identification techniques.
MacCoy, D.E.
1994-01-01
Physical, chemical, and biological data were collected between 1990 and 1992 as part of a detailed study by the U.S. Department of Interior of the effects of irrigation drainage on aquatic resources in the Klamath Basin of California and Oregon. Most of the sites for data collection were in and around the upper and lower sump of Tule Lake, in the Tule Lake National Wildlife Refuge, and along major drains in Lower Klamath National Wildlife Refuge. The physical and chemical data consist of particle-size determinations and concentrations of carbon, mercury, arsenic, chlorophenoxy acid, and organochlorine, organophosphate, and carbamate pesticides in bottom sediment; and concentrations of organophosphate, carbamate, and pyrethroid pesticides, major and trace inorganic constituents, nitrogen, phosphorus, and organic carbon in water. Continuous dissolved oxygen, pH, specific conduc- tance, and temperature data from selected sites in 1991 and 1992 are presented in graphical form to summarize the diel water-quality conditions. The biological data consists of concentrations of inorganic constituents and organochlorine pesticides in tissue, invertebrate and fish population surveys, fish health surveys, frog call surveys, egg shell thickness of avian eggs, and in situ and static toxicity bioassay data collected in 1991 and 1992 using aquatic bacteria, plants, invertebrates, fish, and bird species as test organisms.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Reitz
1942-10-12
A 1.5 liter sump oven, without stirrer, was used for preparation of Rhein coal with different grinding oils. Partial neutralization of the coal, by mixing sulfuric acid or sulfates with wet coal before drying, was sought. Oven precipitation was reduced by addition of street tar (high middle oil content) and Bruex tar (up to 350/sup 0/C) as well as by a mixture of Estonian slate tar oil and anthracitic tar oil in ratio of 80:20, but there was chalk-coke residue similar to caviar found when the oven was disassembled. Fifty percent neutralization of the coal by sulfuric acid as opposedmore » to untreated coal gave some reduced vaporization and lower asphalt content. Iron sulfate catalyst also gave good results; magnesium sulfate, somewhat less. Though not unequivocally, H/sub 2/SO/sub 4/ and FeSO/sub 4/ both apparently reduced precipitants. A mixture of magnesium sulfate with iron sulfate gave less favorable results over all. Untreated coal with the previous catalysts produced the undesirable caviar-precipitants. The results of the tests were questionable since exactness in components, viscosity, and other problems hindered reproducing the tests consistently. 2 tables.« less
Field pilot test of surfactant-enhanced remediation of trichloroethane DNAPL in a sand aquifer
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jackson, R.E.; Butler, G.W.; Londergan, J.T.
The sequence of lacustrine and outwash deposits beneath a vapor degreasing operation at the Paducah Gaseous Division Plant, Kentucky, is contaminated with trichloroethane due to leakage from a sewer/sump line. A plume of dissolved trichloroethane (TCE) extends throughout an area of approximately 3 km[sup 2] in the Regional Gravel Aquifer (RGA) which is located between 20 and 30 meters below ground surface. It is suspected that some 40,000 liters of TCE might have escaped into the subsurface at Paducah, most of which is still present in the lacustrine deposits and the underlying RGA as DNAPL. A field test to confirmmore » the presence of TCE DNAPL in the sandy, upper portion of the RGA around a monitoring well and to test the efficiency of the surfactant for TCE solubilization is described. The aqueous concentrations of TCE in this well have consistently been measured at 300--550 mg TCE/L over a period of three years. The use of Capillary and Bond numbers to estimate the improbability of mobilization of DNAPL due to the lowering of the interfacial tension is described. The multiphase, multicomponent simulator UTCHEM was used to simulate both the injection and extraction of the surfactant solution and the solubilization of the TCE by the surfactant micelles.« less
An RF Sensor for Gauging Screen-Channel Liquid Acquisition Devices for Cryogenic Propellants
NASA Technical Reports Server (NTRS)
Zimmerli, Gregory A.; Metzger, Scott; Asipauskas, Marius
2014-01-01
A key requirement of a low-gravity screen-channel liquid acquisition device (LAD) is the need to retain 100% liquid in the channel in response to propellant outflow and spacecraft maneuvers. The point at which a screen-channel LAD ingests vapor is known as breakdown, and can be measured several different ways such as: visual observation of bubbles in the LAD channel outflow; a sudden change in pressure drop between the propellant tank and LAD sump outlet; or, an indication by wet-dry sensors placed in the LAD channel or outflow stream. Here we describe a new type of sensor for gauging a screen-channel LAD, the Radio Frequency Mass Gauge (RFMG). The RFMG measures the natural electromagnetic modes of the screen-channel LAD, which is very similar to an RF waveguide, to determine the amount of propellant in the channel. By monitoring several of the RF modes, we show that the RFMG acts as a global sensor of the LAD channel propellant fill level, and enables detection of LAD breakdown even in the absence of outflow. This paper presents the theory behind the RFMG-LAD sensor, measurements and simulations of the RF modes of a LAD channel, and RFMG detection of LAD breakdown in a channel using a simulant fluid during inverted outflow and long-term stability tests.
Pischel, Esther M.; Gannett, Marshall W.
2015-07-24
To better define the effect of increased pumping on drain flow and on the water balance of the groundwater system, the annual water volume pumped from drains in three subareas of the Tule Lake subbasin was estimated and a fine-grid, local groundwater model of the Tule Lake subbasin was constructed. Results of the agricultural-drain flow analysis indicate that groundwater discharge to drains has decreased such that flows in 2012 were approximately 32,400 acre-ft less than the 1997–2000 average flow. This decrease was concentrated in the northern and southeastern parts of the subbasin, which corresponds with the areas of greatest groundwater pumping. Model simulation results of the Tule Lake subbasin groundwater model indicate that increased supplemental pumping is the dominant stress to the groundwater system in the subbasin. Simulated supplemental pumping and decreased recharge from irrigation between 2000 and 2010 totaled 323,573 acre-ft, 234,800 acre-ft (73 percent) of which was from supplemental pumping. The response of the groundwater system to this change in stress included about 180,500 acre-ft (56 percent) of decreased groundwater discharge to drains and a 126,000 acre-ft (39 percent) reduction in aquifer storage. The remaining 5 percent came from reduced groundwater flow to other model boundaries, including the Lost River, the Tule Lake sumps, and interbasin flow.
A free-jet Hg target operating in a high magnetic field intersecting a high-power proton beam
NASA Astrophysics Data System (ADS)
Graves, Van; Spampinato, Philip; Gabriel, Tony; Kirk, Harold; Simos, Nicholas; Tsang, Thomas; McDonald, Kirk; Peter Titus; Fabich, Adrian; Haseroth, Helmut; Lettry, Jacques
2006-06-01
A proof-of-principal experiment to investigate the interaction of a proton beam, high magnetic field, and high-Z target is planned to take place at CERN in early 2007. This experiment is part of the Muon Collider Collaboration, with participants from Brookhaven National Laboratory, Princeton University, Massachusetts Institute Of Technology, European Organization for Nuclear Research-CERN, Rutherford Appleton Laboratory, and Oak Ridge National Laboratory. An unconstrained mercury jet target system that interacts with a high power (1 MW) proton beam in a high magnetic field (15 T) is being designed. The Hg jet diameter is 1-cm with a velocity up to 20 m/s. A laser optical diagnostic system will be incorporated into the target design to permit observation of the dispersal of the jet resulting from interaction with a 24 GeV proton beam with up to 20×1012 ppp. The target system includes instruments for sensing mercury vapor, temperature, flow rate, and sump tank level, and the means to position the jet relative to the magnetic axis of a solenoid and the proton beam. The design considerations for the system include all issues dealing with safely handling approximately 23 l of Hg, transporting the target system and the mercury to CERN, decommissioning the experiment, and returning the mildly activated equipment and Hg to the US.
A free-jet Hg target operating in a high magnetic field intersecting a high-power proton beam
NASA Astrophysics Data System (ADS)
Van Graves; Spampinato, Philip; Gabriel, Tony; Kirk, Harold; Simos, Nicholas; Tsang, Thomas; McDonald, Kirk; Peter Titus; Fabich, Adrian; Haseroth, Helmut; Lettry, Jacques
2006-06-01
A proof-of-principal experiment to investigate the interaction of a proton beam, high magnetic field, and high- Z target is planned to take place at CERN in early 2007. This experiment is part of the Muon Collider Collaboration, with participants from Brookhaven National Laboratory, Princeton University, Massachusetts Institute Of Technology, European Organization for Nuclear Research-CERN, Rutherford Appleton Laboratory, and Oak Ridge National Laboratory. An unconstrained mercury jet target system that interacts with a high power (1 MW) proton beam in a high magnetic field (15 T) is being designed. The Hg jet diameter is 1-cm with a velocity up to 20 m/s. A laser optical diagnostic system will be incorporated into the target design to permit observation of the dispersal of the jet resulting from interaction with a 24 GeV proton beam with up to 20×10 12 ppp. The target system includes instruments for sensing mercury vapor, temperature, flow rate, and sump tank level, and the means to position the jet relative to the magnetic axis of a solenoid and the proton beam. The design considerations for the system include all issues dealing with safely handling approximately 23 l of Hg, transporting the target system and the mercury to CERN, decommissioning the experiment, and returning the mildly activated equipment and Hg to the US.
Integrated, flexible, and rapid geophysical surveying
DOE Office of Scientific and Technical Information (OSTI.GOV)
Miller, S.F.; McGinnis, L.D.; Thompson, M.D.
1993-01-01
Aberdeen Proving Ground (APG), in the state of Maryland (Figure 1), is currently managing a comprehensive Installation Restoration Program involving more than 360 solid-waste managing units contained within 13 study areas. The Edgewood area and two landfills in the Aberdeen area appear on the National Priority List under the Comprehensive Environmental Response, Compensation, and Liability Act. Therefore, APG has entered into an interagency agreement with the US Environmental Protection Agency to address the listed areas. The West Branch of the Canal Creek area (Figure 1), located within the Edgewood area, is one of the areas that requires a Source Definitionmore » Study because there is an ongoing release of volatile organic compounds into the creek. A report prepared by EAI Corporation (1989) included a list of 29 potentially contaminated buildings in the Edgewood area. Sixteen of the buildings contain known contaminants, nine buildings contain unknown contaminants, and four of the buildings are potentially clean. The EAI report recommended that a sampling and monitoring program be established to verify contamination levels in and around each building. Thirteen of the potentially contaminated buildings are in the West Branch of the Canal Creek area and are potential sources of volatile organic compounds. Operations have ceased and the buildings have been abandoned, but processing equipment, sumps, drains, ventilation systems, and underground storage tanks remain. These appurtenances may contain liquid, solid, or vapor contaminants of unknown nature.« less
Integrated, flexible, and rapid geophysical surveying
DOE Office of Scientific and Technical Information (OSTI.GOV)
Miller, S.F.; McGinnis, L.D.; Thompson, M.D.
1993-03-01
Aberdeen Proving Ground (APG), in the state of Maryland (Figure 1), is currently managing a comprehensive Installation Restoration Program involving more than 360 solid-waste managing units contained within 13 study areas. The Edgewood area and two landfills in the Aberdeen area appear on the National Priority List under the Comprehensive Environmental Response, Compensation, and Liability Act. Therefore, APG has entered into an interagency agreement with the US Environmental Protection Agency to address the listed areas. The West Branch of the Canal Creek area (Figure 1), located within the Edgewood area, is one of the areas that requires a Source Definitionmore » Study because there is an ongoing release of volatile organic compounds into the creek. A report prepared by EAI Corporation (1989) included a list of 29 potentially contaminated buildings in the Edgewood area. Sixteen of the buildings contain known contaminants, nine buildings contain unknown contaminants, and four of the buildings are potentially clean. The EAI report recommended that a sampling and monitoring program be established to verify contamination levels in and around each building. Thirteen of the potentially contaminated buildings are in the West Branch of the Canal Creek area and are potential sources of volatile organic compounds. Operations have ceased and the buildings have been abandoned, but processing equipment, sumps, drains, ventilation systems, and underground storage tanks remain. These appurtenances may contain liquid, solid, or vapor contaminants of unknown nature.« less
Development and Application of a Low-Volume Flow System for Solution-State in Vivo NMR.
Tabatabaei Anaraki, Maryam; Dutta Majumdar, Rudraksha; Wagner, Nicole; Soong, Ronald; Kovacevic, Vera; Reiner, Eric J; Bhavsar, Satyendra P; Ortiz Almirall, Xavier; Lane, Daniel; Simpson, Myrna J; Heumann, Hermann; Schmidt, Sebastian; Simpson, André J
2018-06-18
In vivo nuclear magnetic resonance (NMR) spectroscopy is a particularly powerful technique, since it allows samples to be analyzed in their natural, unaltered state, criteria paramount for living organisms. In this study, a novel continuous low-volume flow system, suitable for in vivo NMR metabolomics studies, is demonstrated. The system allows improved locking, shimming, and water suppression, as well as allowing the use of trace amounts of expensive toxic contaminants or low volumes of precious natural environmental samples as stressors. The use of a double pump design with a sump slurry pump return allows algal food suspensions to be continually supplied without the need for filters, eliminating the possibility of clogging and leaks. Using the flow system, the living organism can be kept alive without stress indefinitely. To evaluate the feasibility and applicability of the flow system, changes in the metabolite profile of 13 C enriched Daphnia magna over a 24-h period are compared when feeding laboratory food vs exposing them to a natural algal bloom sample. Clear metabolic changes are observed over a range of metabolites including carbohydrates, lipids, amino acids, and a nucleotide demonstrating in vivo NMR as a powerful tool to monitor environmental stress. The particular bloom used here was low in microcystins, and the metabolic stress impacts are consistent with the bloom being a poor food source forcing the Daphnia to utilize their own energy reserves.
Niethammer, K.R.; White, D.H.; Baskett, T.S.; Sayre, M.W.
1984-01-01
Samples (98) of 16 spp. of animals were collected at Lake Providence, 88 samples of 15 spp. at Lake Bruin and 21 samples of 5 spp. at Lake St. John, Louisiana, between July 15 and Sept. 25, 1980. Residues of 13 organochlorine compounds were identified in these samples. Substantial concentrations of many compounds throughout the food webs of all 3 lakes showed that the lakes acted as sumps, accumulating residues from nearby agricultural land. DDT and its metabolites (DDE, TDE and DDMU [1-chloro-2,2,-bis(p-chlorophenyl)ethylene]), toxaphene and polychlorobiphenyls (PCB) were the principal organochloride residues detected. With few exceptions, biomagnification of the principal residues was clearly illustrated. Tertiary consumers such as green-backed heron (Butorides striatus), snakes, spotted gar (Lepisosteus oculatus) and largemouth bass (Micropterus salmoides) contained the highest residues. Bluegill (Lepomis macrochirus), blacktail shiner (Notropis venustus), yellow-crowned night heron (Nycticorax violaceus) and other secondary consumers contained lower levels of residues. Primary consumers, crayfish (Orconectes lancifer) and threadfin shad (Dorosoma petenense), contained relatively low residue levels of most compounds. Frogs contained lower residue levels than expected based on their position in the food web. Residue levels in immature green-backed herons and .gtoreq. 1 of the longer-lived predators, e.g., snakes, gars or largemouth bass could be monitored to evaluate levels of organochlorine chemical contaminants in aquatic habitats.
Raboni, Massimo; Torretta, Vincenzo
2016-12-01
A conventional biotrickling filter for airborne ammonia nitrification has been modified, by converting the liquid sump into a biological denitrifying reactor. The biotrickling filter achieves an average ammonia removal efficiency of 92.4 %, with an empty bed retention time (EBRT) equal to 36 s and an average ammonia concentration of 54.7 mg Nm -3 in the raw air stream. The denitrification reactor converts ammonia into inert gas N 2 , in addition to other important advantages connected to the alkaline character of the biochemical pathway of the denitrifying bacteria. Firstly, the trickling water crossing the denitrification reactor underwent a notable pH increase from 7.3 to 8.0 which prevented the acidic inhibition of the nitrifying bacteria due to the buildup of nitric and nitrous acids. Secondly, the pH increase created the ideal conditions for the autotrophic nitrifying bacteria. The tests proved that an ammonia removal efficiency of above 90 % can be achieved with an EBRT greater than 30 s and a volumetric load lower than 200 g NH 3 m -3 day -1 . The results of the biofilm observation by using a scanning confocal laser microscope are reported together with the identification of degrading bacteria genera in the biotrickling filter. The efficiency of the plant and its excellent operational stability highlight the effectiveness of the synergistic action between the denitrification reactor and the biotrickling filter in removing airborne ammonia.
Steiner, Lisa; Burgess-Limerick, Robin; Porter, William
2014-03-01
The authors examine the pattern of direction errors made during the manipulation of a physical simulation of an underground coal mine bolting machine to assess the directional control-response compatibility relationships associated with the device and to compare these results to data obtained from a virtual simulation of a generic device. Directional errors during the manual control of underground coal roof bolting equipment are associated with serious injuries. Directional control-response relationships have previously been examined using a virtual simulation of a generic device; however, the applicability of these results to a specific physical device may be questioned. Forty-eight participants randomly assigned to different directional control-response relationships manipulated horizontal or vertical control levers to move a simulated bolter arm in three directions (elevation, slew, and sump) as well as to cause a light to become illuminated and raise or lower a stabilizing jack. Directional errors were recorded during the completion of 240 trials by each participant Directional error rates are increased when the control and response are in opposite directions or if the direction of the control and response are perpendicular.The pattern of direction error rates was consistent with experiments obtained from a generic device in a virtual environment. Error rates are increased by incompatible directional control-response relationships. Ensuring that the design of equipment controls maintains compatible directional control-response relationships has potential to reduce the errors made in high-risk situations, such as underground coal mining.
NASA Technical Reports Server (NTRS)
Zimmerli, Greg; Statham, Geoff; Garces, Rachel; Cartagena, Will
2015-01-01
As part of the NASA Cryogenic Propellant Storage and Transfer (CPST) Engineering Design Unit (EDU) testing with liquid hydrogen, screen-channel liquid acquisition devices (LADs) were tested during liquid hydrogen outflow from the EDU tank. A stainless steel screen mesh (325x2300 Dutch T will weave) was welded to a rectangular cross-section channel to form the basic LAD channel. Three LAD channels were tested, each having unique variations in the basic design. The LADs fed a common outflow sump at the aft end of the 151 cu. ft. volume aluminum tank, and included a curved section along the aft end and a straight section along the barrel section of the tank. Wet-dry sensors were mounted inside the LAD channels to detect when vapor was ingested into the LADs during outflow. The use of warm helium pressurant during liquid hydrogen outflow, supplied through a diffuser at the top of the tank, always led to early breakdown of the liquid column. When the tank was pressurized through an aft diffuser, resulting in cold helium in the ullage, LAD column hold-times as long as 60 minutes were achieved, which was the longest duration tested. The highest liquid column height at breakdown was 58 cm, which is 23 less than the isothermal bubble-point model value of 75 cm. This paper discusses details of the design, construction, operation and analysis of LAD test data from the CPST EDU liquid hydrogen test.
Scott, John E; Stockwell, Robin A
2006-01-01
Cartilage ultrastructure is based on collagen fibrils tied together by proteoglycans (PGs). Interfibrillar orthogonal PG bridges (‘shape modules’) were located by electron histochemistry using Cupromeronic blue methodology. Their frequency and size, similar to those in tendon, cornea, etc., were compatible with biochemical estimates of tissue decoran (formerly decorin), the PG component of shape module bridges. Digestion by hyaluronanase and chondroitinase AC helped to identify aggrecan and decoran and exemplified the destruction of shape modular organization by glycan-splitting agents. The anionic glycosaminoglycan (AGAG) of decoran, dermochondan sulphate (DS, formerly dermatan sulphate), contains l-iduronate, an elastic sugar unit. Chondroitan, keratan (present in aggrecan) and hyaluronan are not similarly elastic but can participate in sliding-filament reversible deformability. Mechanical properties predicted for the interfibrillar bridges accord with anisotropic stress/strain responses of articular cartilage to compressive or tensile stresses. We propose that fluid from pericellular aggrecan-rich domains moves under pressure into the interterritorial fibrillar arrays against the elastic resistance of the shape modules, which return the fluid, post-compression, to its original position. Cartilage is tendon-like, with the addition of expansile aggrecan-rich reservoirs of aqueous shock absorber fluid. Rupture or loss of interfibrillar ties would allow expansile PG to force the collagenous matrix apart, imbibing water, increasing swelling and fissuring – characteristic manifestations of osteoarthrosis (OA), a joint disease of major economic importance. Decoran may be a primary target of the OA disease process. PMID:16581860
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tormey, D.; Waldron, J.; Culbertson, D.
When regulatory concern is high, it is critical to address potential ecological impacts early, and hence [open quotes]close the door[close quotes] on further unnecessary studies, as illustrated by the Chevron Estero Marine Terminal case study. Cutter stock (diesel-like hydrocarbons) leaked from a facility sump, reached the water table, and migrated laterally an unknown distance. Media reports led to heightened public and regulatory concern, and the information gap led to worst-case assumptions about the extent and impact of the release to the biota of a nearby creek (Toro Creek). Chevron undertook a rapid assessment with two goals: define the extent ofmore » cutter stock in soil and groundwater, and close the door on expensive biological studies of Toro Creek. The assessment consisted of installing a large number of small-diameter soil borings and temporary well points, monitor wells, and analyzing soil, groundwater, and hydraulic gradient. The information gap was very rapidly filled with the following comprehensive picture: (1) the cutter stock had mixed with heavy crude oil, was highly adsorptive to soil and practically insoluble in water; (2) the cutter stock had not reached Toro Creek; (3) Toro Creek is always a losing stream, hydraulically connected to groundwater beneath the Chevron facility; (4) the groundwater basin is isolated by bedrock boundaries. Early attention to Toro Creek and the Pacific Ocean, and open communication with concerned agencies effectively limited the investigation to soil and water.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tormey, D.; Waldron, J.; Culbertson, D.
When regulatory concern is high, it is critical to address potential ecological impacts early, and hence {open_quotes}close the door{close_quotes} on further unnecessary studies, as illustrated by the Chevron Estero Marine Terminal case study. Cutter stock (diesel-like hydrocarbons) leaked from a facility sump, reached the water table, and migrated laterally an unknown distance. Media reports led to heightened public and regulatory concern, and the information gap led to worst-case assumptions about the extent and impact of the release to the biota of a nearby creek (Toro Creek). Chevron undertook a rapid assessment with two goals: define the extent of cutter stockmore » in soil and groundwater, and close the door on expensive biological studies of Toro Creek. The assessment consisted of installing a large number of small-diameter soil borings and temporary well points, monitor wells, and analyzing soil, groundwater, and hydraulic gradient. The information gap was very rapidly filled with the following comprehensive picture: (1) the cutter stock had mixed with heavy crude oil, was highly adsorptive to soil and practically insoluble in water; (2) the cutter stock had not reached Toro Creek; (3) Toro Creek is always a losing stream, hydraulically connected to groundwater beneath the Chevron facility; (4) the groundwater basin is isolated by bedrock boundaries. Early attention to Toro Creek and the Pacific Ocean, and open communication with concerned agencies effectively limited the investigation to soil and water.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
This Corrective Action Investigation Plan (CAIP) contains the U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Sites Office's (NNSA/NSO's) approach to collect the data necessary to evaluate corrective action alternatives appropriate for the closure of Corrective Action Unit (CAU) 516, Septic Systems and Discharge Points, Nevada Test Site (NTS), Nevada, under the Federal Facility Agreement and Consent Order. CAU 516 consists of six Corrective Action Sites: 03-59-01, Building 3C-36 Septic System; 03-59-02, Building 3C-45 Septic System; 06-51-01, Sump Piping, 06-51-02, Clay Pipe and Debris; 06-51-03, Clean Out Box and Piping; and 22-19-04, Vehicle Decontamination Area. Located in Areasmore » 3, 6, and 22 of the NTS, CAU 516 is being investigated because disposed waste may be present without appropriate controls, and hazardous and/or radioactive constituents may be present or migrating at concentrations and locations that could potentially pose a threat to human health and the environment. Existing information and process knowledge on the expected nature and extent of contamination of CAU 516 are insufficient to select preferred corrective action alternatives; therefore, additional information will be obtained by conducting a corrective action investigation. The results of this field investigation will support a defensible evaluation of corrective action alternatives in the corrective action decision document. Record of Technical Change No. 1 is dated 3/2004.« less
Laparoscopic Choledochoduodenostomy.
Cuendis-Velázquez, Adolfo; E Trejo-Ávila, Mario; Rosales-Castañeda, Enrique; Cárdenas-Lailson, Eduardo; E Rojano-Rodríguez, Martin; Romero-Loera, Sujey; A Sanjuan-Martínez, Carlos; Moreno-Portillo, Mucio
Today's options for biliary bypass procedures, for difficult choledocholithiasis, range from open surgery to laparo-endoscopic hybrid procedures. The aim of this study was to analyze the outcomes of patients with difficult choledocholithiasis treated with laparoscopic choledochoduodenostomy. We performed a prospective observational study from March 2011 to June 2016. We included patients with difficult common bile duct stones (recurrent or unresolved by ERCP) in which a biliary bypass procedure was required. We performed a laparoscopic bile duct exploration with choledochoduodenostomy and intraoperative cholangioscopy. A total of 19 patients were included. We found female predominance (78.9%), advanced mean age (72.4±12 years) and multiple comorbidities. Most patients with previous episodes of choledocholitiasis or cholangitis, mode 1 (min-max: 1-7). Mean common bile duct diameter 24.9±7mm. Mean operative time 218.5±74min, estimated blood loss 150 (30-600)mL, resume of oral intake 3.2±1 days, postoperative length of stay 4.9±2 days. We found a median of 18 (12-32) months of follow-up. All patients with normalization of liver enzymes during follow-up. One patient presented with sump syndrome and one patient died due to nosocomial pneumonia. Laparoscopic choledochoduodenostomy with intraoperative cholangioscopy seems to be safe and effective treatment for patients with difficult common bile duct stones no resolved by endoscopic procedures. This procedure is a good option for patients with advanced age and multiple comorbidities. We offer all the advantages of minimally invasive surgery to these patients. Copyright © 2017 AEC. Publicado por Elsevier España, S.L.U. All rights reserved.
Setmire, J.G.; Schroeder, R.A.; Densmore, J.N.; Goodbred, S.O.; Audet, D.J.; Radke, W.R.
1993-01-01
Results of a detailed study by the National Irrigation Water-Quality Program (NIWQP), U.S. Department of the Interior, indicate that factors controlling contaminant concentrations in subsurface irrigation drainwater in the Imperial Valley are soil characteristics, hydrology, and agricultural practices. Higher contaminant concentrations commonly were associated with clayey soils, which retard the movement of irrigation water and thus increase the degree of evaporative concentration. Regression of hydrogen- and oxygen-isotope ratios in samples collected from sumps yields a linear drainwater evaporation line that extrapolates through the isotopic composition of Colorado River water, thus demonstrating that Colorado River water is the sole source of subsurface drainwater in the Imperial Valley. Ratios of selenium to chloride indicate that selenium present in subsurface drainwater throughout the Imperial Valley originates from the Colorado River. The selenium load discharged to the Salton Sea from the Alamo River, the largest contributor, is about 6.5 tons/yr. Biological sampling and analysis showed that drainwater contaminants, including selenium, boron, and DDE, are accumulating in tissues of migratory and resident birds that use food sources in the Imperial Valley and the Salton Sea. Selenium concentration in fish-eating birds, shorebirds, and the endangered Yuma clapper rail were at levels that could affect reproduction. Boron concentrations in migratory waterfowl and resident shorebirds were at levels that potentially could cause reduced growth in young. As a result of DDE contamination of food sources, waterfowl and fish-eating birds in the Imperial Valley may be experiencing reproductive impairment.
CFD analysis on gas distribution for different scrubber redirection configurations in sump cut.
Zheng, Y; Organiscak, J A; Zhou, L; Beck, T W; Rider, J P
2015-01-01
The National Institute for Occupational Safety and Health's Office of Mine Safety and Health Research recently developed a series of models using computational fluid dynamics (CFD) to study the gas distribution around a continuous mining machine with various fan-powered flooded bed scrubber discharge configurations. CFD models using Species Transport Model without reactions in FLUENT were constructed to evaluate the redirection of scrubber discharge toward the mining face rather than behind the return curtain. The following scenarios are considered in this study: 100 percent of the discharge redirected back toward the face on the off-curtain side of the continuous miner; 100 percent of the discharge redirected back toward the face, but divided equally to both sides of the machine; and 15 percent of the discharge redirected toward the face on the off-curtain side of the machine, with 85 percent directed into the return. These models were compared against a model with a conventional scrubber discharge, where air is directed away from the face into the return. The CFD models were calibrated and validated based on experimental data and accurately predicted sulfur hexafluoride (SF 6 ) gas levels at four gas monitoring locations. One additional prediction model was simulated to consider a different scrubber discharge angle for the 100 percent redirected, equally divided case. These models identified relatively high gassy areas around the continuous miner, which may not warrant their use in coal mines with medium to high methane liberation rates. This paper describes the methodology used to develop the CFD models, and the validation of the models based on experimental data.
Environmental research on a modified in situ oil shale task process. Progress report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1980-05-01
This report summarizes the progress of the US Department of Energy's Oil Shale Task Force in its research program at the Occidental Oil Shale, Inc. facility at Logan Wash, Colorado. More specifically, the Task Force obtained samples from Retort 3E and Retort 6 and submitted these samples to a variety of analyses. The samples collected included: crude oil (Retort 6); light oil (Retort 6); product water (Retort 6); boiler blowdown (Retort 6); makeup water (Retort 6); mine sump water; groundwater; water from Retorts 1 through 5; retort gas (Retort 6); mine air; mine dust; and spent shale core (Retort 3E).more » The locations of the sampling points and methods used for collection and storage are discussed in Chapter 2 (Characterization). These samples were then distributed to the various laboratories and universities participating in the Task Force. For convenience in organizing the data, it is useful to group the work into three categories: Characterization, Leaching, and Health Effects. While many samples still have not been analyzed and much of the data remains to be interpreted, there are some preliminary conclusions the Task Force feels will be helpful in defining future needs and establishing priorities. It is important to note that drilling agents other than water were used in the recovery of the core from Retort 3E. These agents have been analyzed (see Table 12 in Chapter 2) for several constituents of interest. As a result some of the analyses of this core sample and leachates must be considered tentative.« less
Revealing pMDI Spray Initial Conditions: Flashing, Atomisation and the Effect of Ethanol
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mason-Smith, Nicholas; Duke, Daniel J.; Kastengren, Alan L.
Sprays from pressurised metered-dose inhalers are produced by a transient discharge of a multiphase mixture. Small length and short time scales have made the investigation of the governing processes difficult. Consequently, a deep understanding of the physical processes that govern atomisation and drug particle formation has been elusive. X-ray phase contrast imaging and quantitative radiography were used to reveal the internal flow structure and measure the time-variant nozzle exit mass density of 50 µL metered sprays of HFA134a, with and without ethanol cosolvent. Internal flow patterns were imaged at a magnification of 194 pixels/mm and 7759 frames per second withmore » 150 ps temporal resolution. Spray projected mass was measured with temporal resolution of 1 ms and spatial resolution 6 µm × 5 µm. The flow upstream of the nozzle comprised large volumes of vapour at all times throughout the injection. The inclusion of ethanol prevented bubble coalescence, altering the internal flow structure and discharge. Radiography measurements confirmed that the nozzle exit area is dominantly occupied by vapour, with a peak liquid volume fraction of 13%. Vapour generation in pMDIs occurs upstream of the sump, and the dominant volume component in the nozzle exit orifice is vapour at all times in the injection. Furthermore, the flow in ethanol-containing pMDIs has a bubbly structure resulting in a comparatively stable discharge, whereas the binary structure of propellant-only flows results in unsteady discharge and the production of unrespirable liquid masses.« less
Revealing pMDI Spray Initial Conditions: Flashing, Atomisation and the Effect of Ethanol.
Mason-Smith, Nicholas; Duke, Daniel J; Kastengren, Alan L; Traini, Daniela; Young, Paul M; Chen, Yang; Lewis, David A; Edgington-Mitchell, Daniel; Honnery, Damon
2017-04-01
Sprays from pressurised metered-dose inhalers are produced by a transient discharge of a multiphase mixture. Small length and short time scales have made the investigation of the governing processes difficult. Consequently, a deep understanding of the physical processes that govern atomisation and drug particle formation has been elusive. X-ray phase contrast imaging and quantitative radiography were used to reveal the internal flow structure and measure the time-variant nozzle exit mass density of 50 µL metered sprays of HFA134a, with and without ethanol cosolvent. Internal flow patterns were imaged at a magnification of 194 pixels/mm and 7759 frames per second with 150 ps temporal resolution. Spray projected mass was measured with temporal resolution of 1 ms and spatial resolution 6 µm × 5 µm. The flow upstream of the nozzle comprised large volumes of vapour at all times throughout the injection. The inclusion of ethanol prevented bubble coalescence, altering the internal flow structure and discharge. Radiography measurements confirmed that the nozzle exit area is dominantly occupied by vapour, with a peak liquid volume fraction of 13%. Vapour generation in pMDIs occurs upstream of the sump, and the dominant volume component in the nozzle exit orifice is vapour at all times in the injection. The flow in ethanol-containing pMDIs has a bubbly structure resulting in a comparatively stable discharge, whereas the binary structure of propellant-only flows results in unsteady discharge and the production of unrespirable liquid masses.
Revealing pMDI Spray Initial Conditions: Flashing, Atomisation and the Effect of Ethanol
Mason-Smith, Nicholas; Duke, Daniel J.; Kastengren, Alan L.; ...
2017-01-17
Sprays from pressurised metered-dose inhalers are produced by a transient discharge of a multiphase mixture. Small length and short time scales have made the investigation of the governing processes difficult. Consequently, a deep understanding of the physical processes that govern atomisation and drug particle formation has been elusive. X-ray phase contrast imaging and quantitative radiography were used to reveal the internal flow structure and measure the time-variant nozzle exit mass density of 50 µL metered sprays of HFA134a, with and without ethanol cosolvent. Internal flow patterns were imaged at a magnification of 194 pixels/mm and 7759 frames per second withmore » 150 ps temporal resolution. Spray projected mass was measured with temporal resolution of 1 ms and spatial resolution 6 µm × 5 µm. The flow upstream of the nozzle comprised large volumes of vapour at all times throughout the injection. The inclusion of ethanol prevented bubble coalescence, altering the internal flow structure and discharge. Radiography measurements confirmed that the nozzle exit area is dominantly occupied by vapour, with a peak liquid volume fraction of 13%. Vapour generation in pMDIs occurs upstream of the sump, and the dominant volume component in the nozzle exit orifice is vapour at all times in the injection. Furthermore, the flow in ethanol-containing pMDIs has a bubbly structure resulting in a comparatively stable discharge, whereas the binary structure of propellant-only flows results in unsteady discharge and the production of unrespirable liquid masses.« less
Smith, Kirk P.
2002-01-01
Best management practices (BMPs) near highways are designed to reduce the amount of suspended sediment and associated constituents, including debris and litter, discharged from the roadway surface. The effectiveness of a deep-sumped hooded catch basin, three 2-chambered 1,500-gallon oil-grit separators, and mechanized street sweeping in reducing sediment and associated constituents was examined along the Southeast Expressway (Interstate Route 93) in Boston, Massachusetts. Repeated observations of the volume and distribution of bottom material in the oil-grit separators, including data on particle-size distributions, were compared to data from bottom material deposited during the initial 3 years of operation. The performance of catch-basin hoods and the oil-grit separators in reducing floating debris was assessed by examining the quantity of material retained by each structural BMP compared to the quantity of material retained by and discharged from the oil-grit separators, which received flow from the catch basins. The ability of each structural BMP to reduce suspended-sediment loads was assessed by examining (a) the difference in the concentrations of suspended sediment in samples collected simultaneously from the inlet and outlet of each BMP, and (b) the difference between inlet loads and outlet loads during a 14-month monitoring period for the catch basin and one separator, and a 10-month monitoring period for the second separator. The third separator was not monitored continuously; instead, samples were collected from it during three visits separated in time by several months. Suspended-sediment loads for the entire study area were estimated on the basis of the long-term average annual precipitation and the estimated inlet and outlet loads of two of the separators. The effects of mechanized street sweeping were assessed by evaluating the differences between suspended-sediment loads before and after street sweeping, relative to storm precipitation totals, and by comparing the particle-size distributions of sediment samples collected from the sweepers to bottom-material samples collected from the structural BMPs. A mass-balance calculation was used to quantify the accuracy of the estimated sediment-removal efficiency for each structural BMP. The ability of each structural BMP to reduce concentrations of inorganic and organic constituents was assessed by determining the differences in concentrations between the inlets and outlets of the BMPs for four storms. The inlet flows of the separators were sampled during five storms for analysis of fecal-indicator bacteria. The particle-size distribution of bottom material found in the first and second chambers of the separators was similar for all three separators. Consistent collection of floatable debris at the outlet of one separator during 12 storms suggests that floatable debris were not indefinitely retained.Concentrations of suspended sediment in discrete samples of runoff collected from the inlets of the two separators ranged from 8.5 to 7,110 mg/L. Concentrations of suspended sediment in discrete samples of runoff collected from the outlets of the separators ranged from 5 to 2,170 mg/L. The 14-month sediment-removal efficiency was 35 percent for one separator, and 28 percent for the second separator. In the combined-treatment system in this study, where catch basins provided primary suspended-sediment treatment, the separators reduced the mass of the suspended sediment from the pavement by about an additional 18 percent. The concentrations of suspended sediment in discrete samples of runoff collected from the inlet of the catch basin ranged from 32 to 13,600 mg/L. Concentrations of suspended sediment in discrete samples of runoff collected from the outlet of the catch basin ranged from 25.7 to 7,030 mg/L. The sediment-removal efficiency for individual storms during the 14-month monitoring period for the deep-sumped hooded catch basin was 39 percent.The concentrations of 29 in
Numerical Simulation of Tubular Pumping Systems with Different Regulation Methods
NASA Astrophysics Data System (ADS)
Zhu, Honggeng; Zhang, Rentian; Deng, Dongsheng; Feng, Xusong; Yao, Linbi
2010-06-01
Since the flow in tubular pumping systems is basically along axial direction and passes symmetrically through the impeller, most satisfying the basic hypotheses in the design of impeller and having higher pumping system efficiency in comparison with vertical pumping system, they are being widely applied to low-head pumping engineering. In a pumping station, the fluctuation of water levels in the sump and discharge pool is most common and at most time the pumping system runs under off-design conditions. Hence, the operation of pump has to be flexibly regulated to meet the needs of flow rates, and the selection of regulation method is as important as that of pump to reduce operation cost and achieve economic operation. In this paper, the three dimensional time-averaged Navier-Stokes equations are closed by RNG κ-ɛ turbulent model, and two tubular pumping systems with different regulation methods, equipped with the same pump model but with different designed system structures, are numerically simulated respectively to predict the pumping system performances and analyze the influence of regulation device and help designers make final decision in the selection of design schemes. The computed results indicate that the pumping system with blade-adjusting device needs longer suction box, and the increased hydraulic loss will lower the pumping system efficiency in the order of 1.5%. The pumping system with permanent magnet motor, by means of variable speed regulation, obtains higher system efficiency partly for shorter suction box and partly for different structure design. Nowadays, the varied speed regulation is realized by varied frequency device, the energy consumption of which is about 3˜4% of output power of the motor. Hence, when the efficiency of variable frequency device is considered, the total pumping system efficiency will probably be lower.
Maltby, J Roger; Pytka, Saul; Watson, Neil C; Cowan, Robert A McTaggart; Fick, Gordon H
2004-02-01
To determine whether, in obese [body mass index (BMI) > 30 kg.m(2)] patients, oral intake of 300 mL clear liquid two hours before elective surgery affects the volume and pH of gastric contents at induction of anesthesia. A single-blind, randomized study of 126 adult patients, age > or = 18 yr, ASA physical status I or II, BMI > 30 kg.m(2) who were scheduled for elective surgery under general anesthesia. Patients were excluded if they had diabetes mellitus, symptoms of gastroesophageal reflux, or had taken medication within 24 hr that affects gastric secretion, gastric fluid pH or gastric emptying. All patients fasted from midnight and were randomly assigned to fasting or fluid group. Two hours before their scheduled time of surgery, all patients drank 10 mL of water containing phenol red 50 mg. Those in the fluid group followed with 300 mL clear liquid of their choice. Immediately following induction of general anesthesia and tracheal intubation, gastric contents were aspirated through a multiorifice Salem sump tube. The fluid volume, pH and phenol red concentration were recorded. Median (range) values in fasting vs fluid groups were: gastric fluid volume 26 (3-107) mL vs 30 (3-187) mL, pH 1.78 (1.31-7.08) vs 1.77 (1.27-7.34) and phenol red retrieval 0.1 (0-30)% vs 0.2 (0-15)%. Differences between groups were not statistically significant. Obese patients without comorbid conditions should follow the same fasting guidelines as non-obese patients and be allowed to drink clear liquid until two hours before elective surgery, inasmuch as obesity per se is not considered a risk factor for pulmonary aspiration.
Bhatia, Nidhi; Palta, Sanjeev; Arora, Kanika
2011-01-01
Introduction: Pulmonary aspiration of gastric contents remains one of the most feared complications of anesthesia. A gastric pH of 2.5 or less and a volume of 25 ml (0.4 ml/kg body weight) or more in average adult patients are considered critical factors for the development of pulmonary damage in adults. Materials and Methods: This study compared the efficacy of a single oral dose of erythromycin (a macrolide antibiotic) with oral pantoprazole (a proton pump inhibitor) on pre-operative gastric fluid volume and pH in a prospective, randomized, double-blind controlled fashion in 80 adult patients (of ASA physical status I and II) planned for elective surgery under general anesthesia. Patients were divided into two groups of 40 patients each. The pantoprazole group (Group I) received oral pantoprazole 40 mg and the erythromycin group (Group II) received oral erythromycin 250 mg at least 1 h prior to the induction of anesthesia. After tracheal intubation, gastric fluid was aspirated via a Salem Sump tube and its volume and pH were measured. Results: Although both erythromycin and pantoprazole decreased the gastric fluid volume to a similar extent, the decrease in gastric fluid acidity by pantoprazole was significantly greater than that by erythromycin. The proportion of patients at risk of pulmonary aspiration according to traditional criteria, i.e. pH ≤2.5 and volume ≥25ml, was lower in the pantoprazole group. Conclusion: Administration of pantoprazole was found to be more useful than a sub-therapeutic dose of erythromycin in decreasing both volume and acidity of gastric content. PMID:21772679
Sarkar, Atanu; Wilton, Derek Hc; Fitzgerald, Erica
2017-04-01
Radon is the second leading cause of lung cancer after smoking. In Canada, the health authorities have no access to comprehensive profile of the communities built over uranium-rich micro-geological settings. The present indoor radon monitoring guideline is unable to provide an accurate identification of health hazards due to discounting several parameters of housing characteristics. To explore indoor radon levels in a micro-geological setting known for high uranium in bedrock and to develop a theoretical model for a revised radon testing protocol. We surveyed a remote Inuit community in Labrador, located in the midst of uranium belt. We selected 25 houses by convenience sampling and placed electret-ion-chamber radon monitoring devices in the lowest levels of the house (basement/crawl space). The standard radon study questionnaire developed and used by Health Canada was used. 7 (28%) houses had radon levels above the guideline value (range 249 to 574 Bq/m 3 ). Housing characteristics, such as floors, sump holes, ventilation, and heating systems were suspected for high indoor radon levels and health consequences. There is a possibility of the existence of high-risk community in a low-risk region. The regional and provincial health authorities would be benefited by consulting geologists to identify potentially high-risk communities across the country. Placing testing devices in the lowest levels provides more accurate assessment of indoor radon level. The proposed protocol, based on synchronized testing of radon (at the lowest level of houses and in rooms of normal occupancy) and thorough inspection of the houses will be a more effective lung cancer prevention strategy.
Evaluation of a hybrid hydrostatic bearing for cryogenic turbopump application
NASA Technical Reports Server (NTRS)
Spica, P. W.; Hannum, N. P.; Meyer, S. D.
1986-01-01
A hybrid hydrostatic bearing was designed to operate in liquid hydrogen at speeds to 80,000 rpm and radial loads to 440 n (100 lbf). The bearing assembly consisted of a pair of 20-mm angular-contact ball bearings encased in a journal, which was in turn supported by a fluid film of liquid hydrogen. The size and operating conditions of the bearing were selected to be compatible with the operating requirements of an advanced technology turbopump. Several test parameters were varied to characterize the bearing's steady-state operation. The rotation of the tester shaft was varied between 0 and 80,000 rpm. Bearing inlet fluid pressure was varied between 2.07 and 4.48 MPa (300 and 650 psia), while the fluid sump pressure was independently varied between 0.34 and 2.07 MPa (50 and 300 psia). The maximum radial load applied to the bearing was 440 N (110 lbf). Measured hybrid-hydrostatic-bearing stiffness was 1.5 times greater than predicted, while the fluid flow rate through the bearing was 35 to 65 percent less than predicted. Under two-phase fluid conditions, the stiffness was even greater and the flow rate was less. The optimal pressure ratio for the bearing should be between 0.2 and 0.55 depending on the balance desired between bearing efficiency and stiffness. Startup and shutdown cyclic tests were conducted to demonstrate the ability of the hybrid-hydrostatic-bearing assembly to survive at least a 300-firing-duty cycle. For a typical cycle, the shaft was accelerated to 50,000 rpm in 1.8 sec. The bearing operated for 337 start-stop cycles without failure.
Groves-Kirkby, C J; Denman, A R; Phillips, P S; Crockett, R G M; Woolridge, A C; Tornberg, R
2006-05-01
Although United Kingdom (UK) Building Regulations applicable to houses constructed since 1992 in Radon Affected Areas address the health issues arising from the presence of radon in domestic properties and specify the installation of radon-mitigation measures during construction, no legislative requirement currently exists for monitoring the effectiveness of such remediation once construction is completed and the houses are occupied. To assess the relative effectiveness of During-Construction radon reduction and Post-Construction remediation, radon concentration data from houses constructed before and after 1992 in Northamptonshire, UK, a designated Radon Affected Area, was analysed. Post-Construction remediation of 73 pre-1992 houses using conventional fan-assisted sump technology proved to be extremely effective, with radon concentrations reduced to the Action Level, or below, in all cases. Of 64 houses constructed since 1992 in a well-defined geographical area, and known to have had radon-barrier membranes installed during construction, 11% exhibited radon concentrations in excess of the Action Level. This compares with the estimated average for all houses in the same area of 17%, suggesting that, in some 60% of the houses surveyed, installation of a membrane has not resulted in reduction of mean annual radon concentrations to below the Action Level. Detailed comparison of the two data sets reveals marked differences in the degree of mitigation achieved by remediation. There is therefore an ongoing need for research to resolve definitively the issue of radon mitigation and to define truly effective anti-radon measures, readily installed in domestic properties at the time of construction. It is therefore recommended that mandatory testing be introduced for all new houses in Radon Affected Areas.
Y-12 Groundwater Protection Program Groundwater Monitoring Data Compendium, Revision 1
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
This document is a compendium of water quality and hydrologic characterization data obtained through December 2005 from the network of groundwater monitoring wells and surface water sampling stations (including springs and building sumps) at the U.S. Department of Energy (DOE) Y-12 National Security Complex (Y-12) in Oak Ridge, Tennessee that have been sampled since January 2003. The primary objectives of this document, hereafter referenced as the Y-12 Groundwater Protection Program (GWPP) Compendium, are to: (1) Serve as a single-source reference for monitoring data that meet the requirements of the Y-12 GWPP, as defined in the Y-12 GWPP Management Plan (BWXTmore » Y-12 L.L.C. [BWXT] 2004); (2) Maintain a detailed analysis and evaluation of the monitoring data for each applicable well, spring, and surface water sampling station, with a focus on results for the primary inorganic, organic, and radiological contaminants in groundwater and surface water at Y-12; and (3) Ensure retention of ''institutional knowledge'' obtained over the long-term (>20-year) history of groundwater and surface water monitoring at Y-12 and the related sources of groundwater and surface water contamination. To achieve these goals, the Y-12 GWPP Compendium brings together salient hydrologic, geologic, geochemical, water-quality, and environmental compliance information that is otherwise disseminated throughout numerous technical documents and reports prepared in support of completed and ongoing environmental contamination assessment, remediation, and monitoring activities performed at Y-12. The following subsections provide background information regarding the overall scope and format of the Y-12 GWPP Compendium and the planned approach for distribution and revision (i.e., administration) of this ''living'' document.« less
Closure Report for Corrective Action Unit 516: Septic Systems and Discharge Points
DOE Office of Scientific and Technical Information (OSTI.GOV)
NSTec Environmental Restoration
Corrective Action Unit (CAU) 516 is located in Areas 3, 6, and 22 of the Nevada Test Site. CAU 516 is listed in the Federal Facility Agreement and Consent Order of 1996 as Septic Systems and Discharge Points, and is comprised of six Corrective Action Sites (CASs): {sm_bullet} CAS 03-59-01, Bldg 3C-36 Septic System {sm_bullet} CAS 03-59-02, Bldg 3C-45 Septic System {sm_bullet} CAS 06-51-01, Sump and Piping {sm_bullet} CAS 06-51-02, Clay Pipe and Debris {sm_bullet} CAS 06-51-03, Clean Out Box and Piping {sm_bullet} CAS 22-19-04, Vehicle Decontamination Area The Nevada Division of Environmental Protection (NDEP)-approved corrective action alternative for CASsmore » 06-51-02 and 22-19-04 is no further action. The NDEP-approved corrective action alternative for CASs 03-59-01, 03-59-02, 06-51-01, and 06-51-03 is clean closure. Closure activities included removing and disposing of total petroleum hydrocarbon (TPH)-impacted septic tank contents, septic tanks, distribution/clean out boxes, and piping. CAU 516 was closed in accordance with the NDEP-approved CAU 516 Corrective Action Plan (CAP). The closure activities specified in the CAP were based on the recommendations presented in the CAU 516 Corrective Action Decision Document (U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office, 2004). This Closure Report documents CAU 516 closure activities. During closure activities, approximately 186 tons of hydrocarbon waste in the form of TPH-impacted soil and debris, as well as 89 tons of construction debris, were generated and managed and disposed of appropriately. Waste minimization techniques, such as field screening of soil samples and the utilization of laboratory analysis to characterize and classify waste streams, were employed during the performance of closure work.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Salame-Alfie, A.; Alibozek, R.
1995-12-31
EAD Metallurgical, Inc., operated a facility in Tonawanda, New York, in which it utilized Americium 241 (Am-241) for the production of foil sources for use in smoke detectors. EAD was in operation between 1977 and 1983. By 1983, the company started losing money, and decided to relocate to Mexico. Before closing down its Tonawanda operation, however, it was required by the New York State Department of Labor (DOL) to decontaminate its facility to limits specified by DOL. No records of discharges to the sewer system were kept during this decontamination effort. Unsuccessful decontamination efforts by several EAD employees and contractorsmore » left the building contaminated, in particular the concrete floors and walls. To determine the scope of work for the decontamination project, staff from the New York State Departments of Health (DOH) and Environmental Conservation (DEC) conducted a Characterization Survey of the facility in 1993. This survey identified contamination levels of Am-241 in excess of release limits throughout the building, in the soil outside the facility, in pipes for sewage and interior drainage, and in an 8 x 8 x 11 foot sump pit in the building. DOH issued a request for proposals in early 1994 for the decontamination and subsequent decommissioning of the former EAD building, and NES/IES Inc. (NES) was awarded the contract to perform the remediation. DOH`s assignment was to provide an on-site presence to insure the completion of all agreed upon tasks, according to the terms of the contract and work plans submitted by NES. Additionally, the DOH staff acted as a liaison between NES, DOH, DEC and DOL central offices to review, comment and approve all changes or modifications to NES`s approach to the decontamination efforts. The assigned staff was also responsible for conducting confirmatory sampling and surveys of all areas deemed releasable to DOL and DEC criteria by NES.« less
Presser, T.S.; Barnes, Ivan
1985-01-01
Analyses were made for dissolved constituents including selenium (Se) in waters associated with subsurface agricultural drainage from the western San Joaquin Valley of California. In the vicinity of Kesterson National Wildlife Refuge and the Grassland wetlands area Se was found to be mobilized in water. As a consequence of this mobility and bioaccumulation in the aquatic food chain, Se occurred in waterfowl at levels toxic enough to cause deformities and deaths. Se concentrations in sumps that collect subsurface agricultural drainage water and inflows to drains sampled, ultimately leading into Kesterson National Wildlife Refuge and the Grassland, ranged from 84 to 4200 microgram/L (ug/L) Se. Levels of Se were reduced in the San Luis Drain flowing into Kesterson National Wildlife Refute to approximately 300 ug/L Se and in three of the drains sampled flowing into the Grassland to approximately 50 ug/L Se. Serious effects on water fowl habitat were caused by both these levels. Se contents of algal mats and salt crusts from evaporation ponds of the San Luis Drain contained up to parts per million Se. Total ecosystem assessment of Se may be necessary for the evaluation of the toxicity of Se to the environment. No other trace element reported exceeded the various criteria for water at the level of magnitude of Se. Other dissolved constituents and the isotopic ratios of oxygen and hydrogen were analyzed to elucidate water types, reaction states of the aqueous solution with respect to minerals, and the origin of mixed waters. These data will be used later to evaluate the geologic source of Se. Methods used for collection and analysis are described and documented. Hydrologic effects were found to be complex. Preliminary indications from wells are also given. A historical sequence is adhered to and other data from the study area which serve as a guide to the toxicity of Se are included. (Author 's abstract)
Harbison, Justin E.; Henry, Marlon; Corcoran, Peter C.; Zazra, Dave; Xamplas, Christopher
2016-01-01
Stormwater catch basins are commonly treated with larvicides by mosquito control agencies to reduce local populations of mosquito species capable of transmitting West Nile virus. Recent evidence suggests that extended-release larvicides formulated to last up to 180 days in catch basins may not be effective in some basins due to chronic flushing, rapid dissolution, or burying of treatment in sump debris. To investigate if increasing the number of applications could improve effectiveness, a small study was performed over 13 weeks in 2015 to evaluate two extended-release larvicides (Natular™ XRT 180-day tablets and Natular™ T30 30-day tablets) and a larvicide oil (CocoBear™). Over the course of 13 weeks, three groups of eight basins were monitored for mosquitoes, each group receiving Natular™ XRT, Natular™ T30, or CocoBear™ larvicides. All basins received a single application at the beginning of the study period. Once mosquitoes in a basin surpassed the treatment threshold during weekly monitoring, an additional application of the associated larvicide was given to that basin. The number of applications during the study period ranged from 1 to 10 for CocoBear™ basins, 1 to 7 for T30 basins, and 2 to 8 for XRT basins. Overall, the average number of applications and the cost of larvicide per basin were 4.4 applications at $0.66 per Coco-Bear™ basin, 4.4 applications at $6.26 per T30 basin, and 4 applications at $16.56 per XRT basin. Basins treated with XRT and T30 needed reapplications more often than expected, yet were no more effective than CocoBear™, suggesting that increasing the frequency of application of these larvicide formulations may not provide increased mosquito reduction in some basins. PMID:26792998
On the origin and age of the Great Sand Dunes, Colorado
Madole, R.F.; Romig, J.H.; Aleinikoff, J.N.; VanSistine, D.P.; Yacob, E.Y.
2008-01-01
Over the past 100??yr, several hypotheses have been proposed for the origin and age of the Great Sand Dunes. These hypotheses differ widely in the descriptions of dune morphometry, the immediate source of eolian sand, and when sand transport occurred. The primary purpose of this paper is to evaluate these hypotheses and, where warranted, to present new ideas about the origin and age of the Great Sand Dunes. To evaluate the previous hypotheses, we had to develop more detailed information about the surficial geology of the northern San Luis Valley. Thus, we mapped the surficial geology of an area extending several tens of kilometers north, south, and west of the Great Sand Dunes and examined subsurface stratigraphy in more than 200 wells and borings. In addition, we used relative-dating criteria and several radiocarbon and OSL ages to establish the chronology of surficial deposits, and we determined the U-Pb ages of detrital zircons to obtain information about the sources of the sand in the Great Sand Dunes. The first principal finding of this study is that the lower part of the closed basin north of the Rio Grande, referred to here as the sump, is the immediate source of the sand in the Great Sand Dunes, rather than the late Pleistocene flood plain of the Rio Grande (the most widely accepted hypothesis). A second principal finding is that the Great Sand Dunes are older than late Pleistocene. They postdate the draining of Lake Alamosa, which began ??? 440??ka, and predate the time when streams draining the west flank of the Sangre de Cristo Mountains were deflected by incipient dunes that formed near the mountain front. Geomorphic and stratigraphic evidence indicate that this deflection occurred prior to the end of the next to last glaciation (Bull Lake), i.e., prior to ??? 130??ka.
NASA Astrophysics Data System (ADS)
Cheng, Jilin; Zhang, Lihua; Zhang, Rentian; Gong, Yi; Zhu, Honggeng; Deng, Dongsheng; Feng, Xuesong; Qiu, Jinxian
2010-06-01
A dynamic planning model for optimizing operation of variable speed pumping system, aiming at minimum power consumption, was proposed to achieve economic operation. The No. 4 Jiangdu Pumping Station, a source pumping station in China's Eastern Route of South-to-North Water Diversion Project, is taken as a study case. Since the sump water level of Jiangdu Pumping Station is affected by the tide of Yangtze River, the daily-average heads of the pumping system varies yearly from 3.8m to 7.8m and the tide level difference in one day up to 1.2m. Comparisons of operation electricity cost between optimized variable speed and fixed speed operations of pumping system were made. When the full load operation mode is adopted, whether or not electricity prices in peak-valley periods are considered, the benefits of variable speed operation cannot compensate the energy consumption of the VFD. And when the pumping system operates in part load and the peak-valley electricity prices are considered, the pumping system should cease operation or lower its rotational speed in peak load hours since the electricity price are much higher, and to the contrary the pumping system should raise its rotational speed in valley load hours to pump more water. The computed results show that if the pumping system operates in 80% or 60% loads, the energy consumption cost of specified volume of water will save 14.01% and 26.69% averagely by means of optimal variable speed operation, and the investment on VFD will be paid back in 2 or 3 years. However, if the pumping system operates in 80% or 60% loads and the energy cost is calculated in non peak-valley electricity price, the repayment will be lengthened up to 18 years. In China's S-to-N Water Diversion Project, when the market operation and peak-valley electricity prices are taken into effect to supply water and regulate water levels in regulation reservoirs as Hongzehu Lake, Luomahu Lake, etc. the economic operation of water-diversion pumping stations will be vital, and the adoption of VFDs to achieve optimal operation may be a good choice.
DOE Office of Scientific and Technical Information (OSTI.GOV)
David A. Strand
2004-06-01
This Corrective Action Investigation Plan (CAIP) contains project-specific information for conducting site investigation activities at Corrective Action Unit (CAU) 151: Septic Systems and Discharge Area, Nevada Test Site, Nevada. Information presented in this CAIP includes facility descriptions, environmental sample collection objectives, and criteria for the selection and evaluation of environmental corrective action alternatives. Corrective Action Unit 151 is located in Areas 2, 12, 18, and 20 of the Nevada Test Site, which is 65 miles northwest of Las Vegas, Nevada. Corrective Action Unit 151 is comprised of the nine Corrective Action Sites (CAS) listed below: (1) 02-05-01, UE-2ce Pond; (2)more » 12-03-01, Sewage Lagoons (6); (3) 12-04-01, Septic Tanks; (4) 12-04-02, Septic Tanks; (5) 12-04-03, Septic Tank; (6) 12-47-01, Wastewater Pond; (7) 18-03-01, Sewage Lagoon; (8) 18-99-09, Sewer Line (Exposed); and (9) 20-19-02, Photochemical Drain. The CASs within CAU 151 are discharge and collection systems. Corrective Action Site 02-05-01 is located in Area 2 and is a well-water collection pond used as a part of the Nash test. Corrective Action Sites 12-03-01, 12-04-01, 12-04-02, 12-04-03, and 12-47-01 are located in Area 12 and are comprised of sewage lagoons, septic tanks, associated piping, and two sumps. The features are a part of the Area 12 Camp housing and administrative septic systems. Corrective Action Sites 18-03-01 and 18-99-09 are located in the Area 17 Camp in Area 18. These sites are sewage lagoons and associated piping. The origin and terminus of CAS 18-99-09 are unknown; however, the type and configuration of the pipe indicates that it may be a part of the septic systems in Area 18. Corrective Action Site 20-19-02 is located in the Area 20 Camp. This site is comprised of a surface discharge of photoprocessing chemicals.« less
Lava tubes and aquifer vulnerability in the upper Actopan River basin, Veracruz, México
NASA Astrophysics Data System (ADS)
Espinasa-Pereña, R.; Delgado Granados, H.
2011-12-01
Rapid infiltration leads to very dry conditions on the surface of some volcanic terrains, with large allogenic streams sometimes sinking underground upon reaching a lava flow. Aquifers in lava flows tend to be heterogeneous and discontinuous, generally unconfined and fissured, and have high transmissivity. Springs associated with basalts may be very large but are typically restricted to lava-flow margins. Concern has been expressed regarding the potential for lava-tube caves to facilitate groundwater contamination similar to that afflicting some karst aquifers (Kempe et al., 2003; Kiernan et al., 2002; Halliday 2003). The upper Actopan River basin is a series of narrow valleys excavated in Tertiary volcanic brechias. Several extensive Holocene basaltic tube-fed lava flows have partially filled these valleys. The youngest and longest flow originates at El Volcancillo, a 780 ybP monogenetic volcano. It is over 50 km long, and was fed through a major master tube, the remains of which form several lava-tube caves (Gassos and Espinasa-Pereña, 2008). Another tube-fed flow initiates at a vent at the bottom of Barranca Huichila and can be followed for 7 km to where it is covered by the Volcancillo flow. The Huichila River is captured by this system of lava tubes and can be followed through several underground sections. In dry weather the stream disappears at a sump in one of these caves, although during hurricanes it overflows the tube, floods the Tengonapa plain, and finally sinks through a series of skylights into the master tube of the Volcancillo flow. Near villages, the cave entrances are used as trash dumps, which are mobilized during floods. These include household garbage, organic materials associated with agriculture and even medical supplies. This is a relatively recent phenomenon, caused by population growth and the building of houses above the lava flows. The water resurges at El Descabezadero, gushing from fractures in the lava above the underlying brechias, giving birth to the Actopan River. The water is so clear that people assume that it is pure and has been naturally filtered.
Groundwater pollution around an industrial area in the coastal stretch of Maharashtra State, India.
Naik, Pradeep K; Dehury, Biranchi N; Tiwari, Arun N
2007-09-01
The main objective of this paper is to examine pollution threat, especially to the groundwater resources, around Tarapur industrial area (also called the Tarapur MIDC area) located on the Arabian Sea Coast in Thane District of Maharashtra State, India and suggest remedial measures that may also be relevant to other industrial areas on the Indian Sea Coast. One hundred and thirty one samples were collected from various sources, such as dugwells, borewells, dug-cum-borewells, effluent sumps, drainage channels (effluent channels), creeks and ocean, for chemical analyses. These analyses show that the area in general is characterized by hard water and high salinity hazard, possibly due to its proximity and hydraulic connection with the sea. Although the potability of groundwater is questionable in certain pockets, it is good enough for irrigation purposes at present. Low pH value and high heavy metal contents in the adjoining Muramba creek water is a matter of great concern and may be attributed to the indiscriminate disposal of industrial effluents to the drainage channels connecting the creek. Muramba Creek is well connected with the Arabian Sea, and there are evidences of seawater intrusion around this creek. Because of the fact that Muramba Creek is highly polluted, and is hydraulically connected with the dugwells and borewells surrounding the creek, it cannot be ruled out that the groundwater around this creek is susceptible to contamination. Unless measures are not taken immediately to stop the indiscriminate disposal of the solid wastes and liquid effluents in open ground and drainage channels, and measures are not taken to maintain the appropriate pH values at the effluent treatment facilities before their disposal, the problem would indeed be formidable one day, and it will be too late then for the authorities to take care of the resulting maladies. Few suggestions have been given for controlling and managing the industrial pollution around the Tarapur MIDC area. These suggestions are relevant to other industrial areas situated on the 7,000 km long Indian Sea Coast.
Design, Manufacture and Test of Cryotank Components
NASA Technical Reports Server (NTRS)
McCarville, Douglas A.; Guzman, Juan C.; Dillon. Alexandra K.; Jackson, Justin R.; Birkland, Jordan O.
2017-01-01
On the composite cryotank technology development (CCTD) project, the Boeing Company built two cryotanks as a means of advancing technology and manufacturing readiness levels (TRL and MRL) and lowering the risk of fabricating full-scale fuel containment vessels.1 CCTD focused on upper stage extended duration applications where long term storage of propellants is required. The project involved the design, analysis, fabrication, and test of manufacturing demonstration units (MDU), a 2.4 m (precursor) and a 5.5 m composite cryotank. Key design features included one-piece wall construction to minimize overall weight (eliminating the need for a bellyband joint), 3-dimensionally (3D) reinforced y-joint material to alleviate stress concentrations at the tank to skirt interface and a purge-able ?uted core skirt to carry high axial launch loads. The tanks were made with OoA curing pre-impregnated (prepreg) carbon/epoxy (C/E) slit-tape tow (STT) that contained thin micro-crack resistant plies in the tank wall center to impede permeation. The tanks were fabricated at Boeing's Seattle-based Advanced Development Center (ADC) using RAFP and multipiece break-down tooling. The tooling was designed and built by Janicki Industries (JI) at Sedro Woolley, Washington. Tank assemblage consisted of co-bonded dome covers, one-piece ?uted core skirts and mechanical fastened cover/sump. Ultrasonic inspection was performed after every cure or bond and a structural health monitoring system (SHMS) was installed to identify potential impact damage events (in-process and/or during transportation). The tanks were low temperature tested at NASA's George C. Marshall Space Flight Center (MSFC) in Huntsville, Alabama. The testing, which consisted of a sequence of ?ll/drain pressure and thermal cycles using LH2, was successfully concluded in 2012 on the 2.4 m tank and in 2014 on the 5.5 m tank. Structural, thermal, and permeation performance data was obtained. 2 Critical design features and manufacturing advancements, which helped to validate 25% weight and 30% cost reduction projections, were matured. These advancements will help to guide future composite tank integration activities on next generation long duration aircraft and space launch vehicles. Because CCTD addressed innovative design features, heavy lift size scale-up, multipiece captured tooling, new generation automated material placement (AMP) equipment and OoA materials, this chapter should be of interest to educators, students and manufacturers of composite hardware and ?ight vehicles.
Bellholes: Ceiling Cavities Eroded By Bats in Caves of the Neotropical Climates
NASA Astrophysics Data System (ADS)
Miller, T.
2014-12-01
Hundreds of thousands of symmetrical, vertical, bullet-shaped cavities known as bellholes are present in the ceilings of caves restricted to the tropical Americas. Most have circular diameters (rarely influenced by joints or bedding) of at least 30 cm, and may be several meters in height. They are often paired with bellbasins (shallow depressions located vertically beneath them that contain guano produced by bats). Members of the species Artibeus jamaicensis (Jamaican Fruit Bat) are almost exclusive users of these roosts. Brown streaks flowing down the sides of the bellholes and centimeters-thick rinds of the basins below are largely apatite minerals produced by the reaction of the host limestone with phosphoric acids in the guano.Many bellholes have developed in speleothem in the cave ceilings, disproving early theories that they are the result of solution by phreatic currents in flooded caves. A. jamaicensis roosts singly or in harem groups of 2-14 that commonly cluster in the bellholes and it is likely that these social habits of this species focus corrosion resulting from the transfer of feces to rock (producing altered rock then removed by claws) to create discretely-spaced upward-growing cavities. Fossil evidence from Jamaica supports an arrival there from the mainland in the past 12,000 years, suggesting bellholes and bellbasins are geologically recent features in the Caribbean islands. Their locations (not all cave passages have bellholes) can provide information on the hydrological history or microclimate of a cave, due to the absence of both bellholes and bats in some specific situations, e.g. where physical barriers exist such as sumps, small airspaces above streams or through rock collapses, or with increasing distance from an entrance.Smaller circular, increasingly-indented ceiling cavities demonstrate a sequence of bellhole development. Small (23 cm diameter, 9 cm high), circular, streaked cavities in a limestone drainage tunnel constructed in 1927 in Puerto Rico suggest that a 30 cm diameter, 50 cm high bellhole could develop in fewer than 900 years. The numbers of bellholes and bellbasins suggest they may be an important post-formational erosional process in tropical caves, e.g. 4.8 linear cm of ceiling rock has been eroded just from the bellholes of only the first 600 m of a single cave in Puerto Rico.
Safferman, Steven I; Burks, Bennette D; Parker, Robert A
2004-01-01
The need to improve on-site wastewater treatment processes is being realized as populations move into more environmentally sensitive regions and regulators adopt the total maximum daily load approach to watershed management. Under many conditions, septic systems do not provide adequate treatment; therefore, advanced systems are required. These systems must remove significant amounts of biochemical oxygen demand (BOD) and suspended solids, and substantially nitrify, denitrify, and remove phosphorus. Many existing advanced on-site wastewater systems effectively remove BOD, suspended solids, and ammonia, but few substantially denitrify and uptake phosphorus. The purpose of this research was to design and test modifications to an existing on-site wastewater treatment system to improve denitrification and phosphorus removal. The Nayadic (Consolidated Treatment Systems, Inc., Franklin, Ohio), an established, commercially available, extended-aeration, activated sludge process, was used to represent a typical existing system. Several modifications were considered based on a literature review, and the option with the best potential was tested. To improve denitrification, a supplemental treatment tank was installed before the Nayadic and a combination flow splitter, sump, and pump box with a recirculation system was installed after it. A recirculation pump returned a high proportion of the system effluent back to the supplemental treatment tank. Two supplemental treatment tank sizes, three flowrates, and three recirculation rates were tested. Actual wastewater was dosed as brief slugs to the system in accordance with a set schedule. Several ion-exchange resins housed in a contact column were tested on the effluent for their potential to remove phosphorus. Low effluent levels of five-day biochemical oxygen demand, suspended solids, and total nitrogen were achieved and substantial phosphorous removal was also achieved using a 3780-L supplemental treatment tank, a recirculation ratio of 5:1, and a fine-grain activated aluminum-oxide-exchange media. Good results were also obtained with an 1890-L supplemental treatment tank and a recirculation ratio of 3:1. The most significant benefit of the supplemental treatment tank, in combination with the recirculation system, appears to be the low nitrogen concentration dosed to the Nayadic. By reducing the nitrogen concentration and spreading out its mass over time during no-flow periods, the Nayadic's inherent low-level denitrifying capacity was more closely matched and effective treatment was achieved.
Modeling transport phenomena and uncertainty quantification in solidification processes
NASA Astrophysics Data System (ADS)
Fezi, Kyle S.
Direct chill (DC) casting is the primary processing route for wrought aluminum alloys. This semicontinuous process consists of primary cooling as the metal is pulled through a water cooled mold followed by secondary cooling with a water jet spray and free falling water. To gain insight into this complex solidification process, a fully transient model of DC casting was developed to predict the transport phenomena of aluminum alloys for various conditions. This model is capable of solving mixture mass, momentum, energy, and species conservation equations during multicomponent solidification. Various DC casting process parameters were examined for their effect on transport phenomena predictions in an alloy of commercial interest (aluminum alloy 7050). The practice of placing a wiper to divert cooling water from the ingot surface was studied and the results showed that placement closer to the mold causes remelting at the surface and increases susceptibility to bleed outs. Numerical models of metal alloy solidification, like the one previously mentioned, are used to gain insight into physical phenomena that cannot be observed experimentally. However, uncertainty in model inputs cause uncertainty in results and those insights. The analysis of model assumptions and probable input variability on the level of uncertainty in model predictions has not been calculated in solidification modeling as yet. As a step towards understanding the effect of uncertain inputs on solidification modeling, uncertainty quantification (UQ) and sensitivity analysis were first performed on a transient solidification model of a simple binary alloy (Al-4.5wt.%Cu) in a rectangular cavity with both columnar and equiaxed solid growth models. This analysis was followed by quantifying the uncertainty in predictions from the recently developed transient DC casting model. The PRISM Uncertainty Quantification (PUQ) framework quantified the uncertainty and sensitivity in macrosegregation, solidification time, and sump profile predictions. Uncertain model inputs of interest included the secondary dendrite arm spacing, equiaxed particle size, equiaxed packing fraction, heat transfer coefficient, and material properties. The most influential input parameters for predicting the macrosegregation level were the dendrite arm spacing, which also strongly depended on the choice of mushy zone permeability model, and the equiaxed packing fraction. Additionally, the degree of uncertainty required to produce accurate predictions depended on the output of interest from the model.
NASA Astrophysics Data System (ADS)
Nelson, Mark; Dempster, William; Highfield, Eric
A number of researchers in space bioregenerative life support systems (BLSS) have advocated the inclusion of fish-rearing. Fish have relatively high feed to production ratios and can utilize some waste products from other system components. In recent years, there has been much advance in an approach to combining fish-culture with hydroponically-grown crops called “aquaponics”. Aquaponics systems vary but generally include: fish-rearing unit, settling basin, biofilter, hydroponic plant unit and sump where water is pumped back and the cycle continues. Aquaponics research and application has grown since these systems have the potential to increase overall productivity of both crops and fish. Since the fish waste is used as the growth medium of the food plants, there are environmental benefits in reduced discharge of nutrient-rich wastewater which has been one of the drawbacks of conventional aquaculture. In addition, since water use is reduced 95+% over field agriculture, since water from the hydroponic tanks is fed back to the fish tanks and water is recycled apart from evapotranspiration losses, conservation of water resources and applications in water-limited arid regions are other benefits fueling the spread of aquaponics around the world. These considerations also make utilization of aquaponic approaches desirable in BLSS for space application. This paper will examine some recent research results with aquaponics and explore how it might be utilized for food production and reduction of consumables in space life support. In addition, a review and comparison with other fish-culture options previously advanced will evaluate whether aquaponics can improve production efficiency, reduce inputs and better recycle critical resources. Finally, we will explore whether for the space environment, even more advanced aquaponics systems are possible where consumables such as fish-food can be partially or completely supplied from other subsystems of the BLSS and ET water losses compensated by condensation from humidity in the atmosphere. For longer term space life support, the paper will evaluate how aquaponics might integrate soil-like-substrate made from inedible crop biomass, utilize algae (edible) for water quality improvement in the fish tanks and how any wastes might be more fully integrated in other BLSS subsystems to improve overall closure ratio.
NASA Astrophysics Data System (ADS)
Mouhouddine, Alihoumadi; Yameogo, Suzanne; Genthon, Pierre; Travi, Yves
2016-04-01
African cities are presently facing the combined impacts of growing urbanization and climate change. In several instances; providing safe drinking water for all is still a challenge, especially for cities located on basement aquifers, were groundwater is scarce. Here we assess the effects of climate change and land use change on groundwater amount and quality in the main city of Ouagadougou (Burkina Faso) taking advantage of the CIEH borehole, where a mostly continuous record lasts since 1978. This record spans most of the Great African Drought (1970-1990) and recovery from the Drought since the 2000s. A piezometric network of 14 wells and boreholes was setup around the CIEH borehole and monitored during the 2013-2014 hydrologic year. The piezometric network spans an old settlement, the Ouagadougou University, a vegetable gardening area and a natural forested area. Water balance estimates are provided by a 1D box model. The study area, although it lies partly on an old settlement in Ouagadougou and on the University area, presents a rather uniform runoff coefficient of 22% and ET amounting to 80-90 % of rainfall, which usually characterizes natural areas. It is suspected that the almost absence of asphalted surfaces, the presence of trees and flow of rainwater from roofs toward bare soils or sumps could be responsible of this budget. However, the two wells located in the forested Bangr Weogo recreational area are characterized by almost no runoff and a nearly 100 % ET. While drinking water can be pumped in several places in the city of Ouagadougou, chemical major analyses show that two mechanisms impact groundwater quality during the rainy season: (i) rise of the water table at pit latrine level, mainly in old settlements, and entrainment of harmful substances from soil to the aquifer in gardening area near some artisan activities. The CIEH borehole is not fully representative of its neighboring area since (i) it lies in a piezometric low, (ii) it presents the smallest annual amplitude of the whole network. Modeling the 1978-2013 record at this borehole requires a nearly 10 % increase of recharge since 1990-1991, a period corresponding to partial and temporary recovery of rainfall after the Drought. Its water level lies nearly at the 1978 level; however, without the parameter change in 1991, it would lies 3 m below this level. Further extensive characterizations of hydrological properties near the CIEH borehole are suggested to allow further interpretations of its unique record.
Bahrami, Saeed; Doulati Ardejani, Faramarz; Aslani, Soheyla; Baafi, Ernest
2014-12-01
The groundwater inflow into a mine during its life and after ceasing operations is one of the most important concerns of the mining industry. This paper presents a hydrogeological assessment of the Irankuh Zn-Pb mine at 20 km south of Esfahan and 1 km northeast of Abnil in west-Central Iran. During mine excavation, the upper impervious bed of a confined aquifer was broken and water at high-pressure flowed into an open pit mine associated with the Kolahdarvazeh deposit. The inflow rates were 6.7 and 1.4 m(3)/s at the maximum and minimum quantities, respectively. Permeability, storage coefficient, thickness and initial head of the fully saturated confined aquifer were 3.5 × 10(-4) m/s, 0.2, 30 m and 60 m, respectively. The hydraulic heads as a function of time were monitored at four observation wells in the vicinity of the pit over 19 weeks and at an observation well near a test well over 21 h. In addition, by measuring the rate of pumping out from the pit sump, at a constant head (usually equal to height of the pit floor), the real inflow rates to the pit were monitored. The main innovations of this work were to make comparison between numerical modelling using a finite element software called SEEP/W and actual data related to inflow and extend the applicability of the numerical model. This model was further used to estimate the hydraulic heads at the observation wells around the pit over 19 weeks during mining operations. Data from a pump-out test and observation wells were used for model calibration and verification. In order to evaluate the model efficiency, the modelling results of inflow quantity and hydraulic heads were compared to those from analytical solutions, as well as the field data. The mean percent error in relation to field data for the inflow quantity was 0.108. It varied between 1.16 and 1.46 for hydraulic head predictions, which are much lower values than the mean percent errors resulted from the analytical solutions (from 1.8 to 5.3 for inflow and from 2.16 to 3.5 for hydraulic head predictions). The analytical solutions underestimated the inflow compared to the numerical model for the time period of 2-19 weeks. The results presented in this paper can be used for developing an effective dewatering program.
NASA Astrophysics Data System (ADS)
Wildey, R. A.; Ballestero, T. P.; Roseen, R. M.; Houle, J.
2005-05-01
In our efforts to improve the quality of runoff entering our streams and waterways, stormwater management measures (or BMPs) are being implemented at a rapid pace. Usually designed to treat one or more specific types of contamination or loading, these measures may have unintended consequences that are not well understood. One issue that has not been fully explored is the potential effect these systems have on microbial contamination of the treated runoff. This study evaluates 11 types of treatment systems and their impact on E. coli and Enterococci contamination. Recent research has demonstrated that near-shore sediment may act as a continuous source of bacterial loading in the overlying waters, rather than bacterial loading being solely a temporal, storm-driven phenomenon. Similarly, stormwater management measures that utilize a soil media for filtration or incorporate a sediment sump may also provide conditions conducive to the incubation of fecal coliforms that can then be released into the environment during runoff events. Following with EPA regulatory guidelines for receiving waters, E. coli and Enterococci are used as surrogates for the presence of other potential disease-causing pathogens typically associated with mammalian and avian enteric bacteria. The stormwater management measures being investigated include: subsurface infiltration, surface sand filter, standard detention pond, bioretention area, hydrodynamic separation, subsurface gravel wetland, street sweeping, and vegetated swale. An adjacent porous parking area and a standard asphalt lot that drains to a tree filter are similarly monitored. Influent is supplied by runoff generated by a 9-acre commuter parking lot at the University of New Hampshire in Durham, NH. This influent is distributed equally to the different treatment devices that operate in parallel. Water quality parameters (DO, pH, specific conductivity, temperature) and flow are continuously monitored upstream from the distribution chamber (influent) and downstream from each device (effluent). Automated samplers are used to collect samples during storm events and grab samples are taken between storm events to evaluate the effect of each device or BMP on bacterial populations. Initial data indicate that influent concentrations of fecal coliforms for this parking area often exceed EPA limits for Class A waterbodies. Several of the treatment units appear to substantially reduce (>90% reduction) bacterial loading, while others appear to increase loading during some storm events (>500% increase). This study is on-going and additional sample events from the Spring of 2005 will also be presented.
Clinical investigation of an outbreak of alveolitis and asthma in a car engine manufacturing plant
Robertson, W; Robertson, A S; Burge, C B S G; Moore, V C; Jaakkola, M S; Dawkins, P A; Burd, M; Rawbone, R; Gardner, I; Kinoulty, M; Crook, B; Evans, G S; Harris‐Roberts, J; Rice, S; Burge, P S
2007-01-01
Background Exposure to metal working fluid (MWF) has been associated with outbreaks of extrinsic allergic alveolitis (EAA) in the USA, with bacterial contamination of MWF being a possible cause, but is uncommon in the UK. Twelve workers developed EAA in a car engine manufacturing plant in the UK, presenting clinically between December 2003 and May 2004. This paper reports the subsequent epidemiological investigation of the whole workforce. The study had three aims: (1) to measure the extent of the outbreak by identifying other workers who may have developed EAA or other work‐related respiratory diseases; (2) to provide case detection so that those affected could be treated; and (3) to provide epidemiological data to identify the cause of the outbreak. Methods The outbreak was investigated in a three‐phase cross‐sectional survey of the workforce. In phase I a respiratory screening questionnaire was completed by 808/836 workers (96.7%) in May 2004. In phase II 481 employees with at least one respiratory symptom on screening and 50 asymptomatic controls were invited for investigation at the factory in June 2004. This included a questionnaire, spirometry and clinical opinion. 454/481 (94.4%) responded and 48/50 (96%) controls. Workers were identified who needed further investigation and serial measurements of peak expiratory flow (PEF). In phase III 162 employees were seen at the Birmingham Occupational Lung Disease clinic. 198 employees returned PEF records, including 141 of the 162 who attended for clinical investigation. Case definitions for diagnoses were agreed. Results 87 workers (10.4% of the workforce) met case definitions for occupational lung disease, comprising EAA (n = 19), occupational asthma (n = 74) and humidifier fever (n = 7). 12 workers had more than one diagnosis. The peak onset of work‐related breathlessness was Spring 2003. The proportion of workers affected was higher for those using MWF from a large sump (27.3%) than for those working all over the manufacturing area (7.9%) (OR = 4.39, p<0.001). Two workers had positive specific provocation tests to the used but not the unused MWF solution. Conclusions Extensive investigation of the outbreak of EAA detected a large number of affected workers, not only with EAA but also occupational asthma. This is the largest reported outbreak in Europe. Mist from used MWF is the likely cause. In workplaces using MWF there is a need to carry out risk assessments, to monitor and maintain fluid quality, to control mist and to carry out respiratory health surveillance. PMID:17504818
Clinical investigation of an outbreak of alveolitis and asthma in a car engine manufacturing plant.
Robertson, W; Robertson, A S; Burge, C B S G; Moore, V C; Jaakkola, M S; Dawkins, P A; Burd, M; Rawbone, R; Gardner, I; Kinoulty, M; Crook, B; Evans, G S; Harris-Roberts, J; Rice, S; Burge, P S
2007-11-01
Exposure to metal working fluid (MWF) has been associated with outbreaks of extrinsic allergic alveolitis (EAA) in the USA, with bacterial contamination of MWF being a possible cause, but is uncommon in the UK. Twelve workers developed EAA in a car engine manufacturing plant in the UK, presenting clinically between December 2003 and May 2004. This paper reports the subsequent epidemiological investigation of the whole workforce. The study had three aims: (1) to measure the extent of the outbreak by identifying other workers who may have developed EAA or other work-related respiratory diseases; (2) to provide case detection so that those affected could be treated; and (3) to provide epidemiological data to identify the cause of the outbreak. The outbreak was investigated in a three-phase cross-sectional survey of the workforce. In phase I a respiratory screening questionnaire was completed by 808/836 workers (96.7%) in May 2004. In phase II 481 employees with at least one respiratory symptom on screening and 50 asymptomatic controls were invited for investigation at the factory in June 2004. This included a questionnaire, spirometry and clinical opinion. 454/481 (94.4%) responded and 48/50 (96%) controls. Workers were identified who needed further investigation and serial measurements of peak expiratory flow (PEF). In phase III 162 employees were seen at the Birmingham Occupational Lung Disease clinic. 198 employees returned PEF records, including 141 of the 162 who attended for clinical investigation. Case definitions for diagnoses were agreed. 87 workers (10.4% of the workforce) met case definitions for occupational lung disease, comprising EAA (n = 19), occupational asthma (n = 74) and humidifier fever (n = 7). 12 workers had more than one diagnosis. The peak onset of work-related breathlessness was Spring 2003. The proportion of workers affected was higher for those using MWF from a large sump (27.3%) than for those working all over the manufacturing area (7.9%) (OR = 4.39, p<0.001). Two workers had positive specific provocation tests to the used but not the unused MWF solution. Extensive investigation of the outbreak of EAA detected a large number of affected workers, not only with EAA but also occupational asthma. This is the largest reported outbreak in Europe. Mist from used MWF is the likely cause. In workplaces using MWF there is a need to carry out risk assessments, to monitor and maintain fluid quality, to control mist and to carry out respiratory health surveillance.
DOE Office of Scientific and Technical Information (OSTI.GOV)
NSTec Environmental Restoration
2011-04-30
This Corrective Action Plan has been prepared for Corrective Action Unit (CAU) 562, Waste Systems, in accordance with the Federal Facility Agreement and Consent Order (1996; as amended March 2010). CAU 562 consists of 13 Corrective Action Sites (CASs) located in Areas 2, 23, and 25 of the Nevada National Security Site. Site characterization activities were performed in 2009 and 2010, and the results are presented in Appendix A of the Corrective Action Decision Document for CAU 562. The scope of work required to implement the recommended closure alternatives is summarized. (1) CAS 02-26-11, Lead Shot, will be clean closedmore » by removing shot. (2) CAS 02-44-02, Paint Spills and French Drain, will be clean closed by removing paint and contaminated soil. As a best management practice (BMP), asbestos tile will be removed. (3) CAS 02-59-01, Septic System, will be clean closed by removing septic tank contents. As a BMP, the septic tank will be removed. (4) CAS 02-60-01, Concrete Drain, contains no contaminants of concern (COCs) above action levels. No further action is required; however, as a BMP, the concrete drain will be removed. (5) CAS 02-60-02, French Drain, was clean closed. Corrective actions were completed during corrective action investigation activities. As a BMP, the drain grates and drain pipe will be removed. (6) CAS 02-60-03, Steam Cleaning Drain, will be clean closed by removing contaminated soil. As a BMP, the steam cleaning sump grate and outfall pipe will be removed. (7) CAS 02-60-04, French Drain, was clean closed. Corrective actions were completed during corrective action investigation activities. (8) CAS 02-60-05, French Drain, will be clean closed by removing contaminated soil. (9) CAS 02-60-06, French Drain, contains no COCs above action levels. No further action is required. (10) CAS 02-60-07, French Drain, requires no further action. The french drain identified in historical documentation was not located during corrective action investigation activities. (11) CAS 23-60-01, Mud Trap Drain and Outfall, will be clean closed by removing sediment from the mud trap. As a BMP, the mud trap and outfall pipe will be removed. (12) CAS 23-99-06, Grease Trap, will be clean closed by removing sediment from the grease trap and backfilling the grease trap with grout. (13) CAS 25-60-04, Building 3123 Outfalls, will be clean closed by removing contaminated soil and the sludge-containing outfall pipe.« less
Modification of pure oxygen absorption equipment for concurrent stripping of carbon dioxide
Watten, B.J.; Sibrell, P.L.; Montgomery, G.A.; Tsukuda, S.M.
2004-01-01
The high solubility of carbon dioxide precludes significant desorption within commercial oxygen absorption equipment. This operating characteristic of the equipment limits its application in recirculating water culture systems despite its ability to significantly increase allowable fish loading rates (kg/(L min)). Carbon dioxide (DC) is typically removed by air stripping. This process requires a significant energy input for forced air movement, air heating in cold climates and water pumping. We developed a modification for a spray tower that provides for carbon dioxide desorption as well as oxygen absorption. Elimination of the air-stripping step reduces pumping costs while allowing dissolved nitrogen to drop below saturation concentrations. This latter response provides for an improvement in oxygen absorption efficiency within the spray tower. DC desorption is achieved by directing head-space gases from the spray tower (O2, N2, CO2) through a sealed packed tower scrubber receiving a 2 N NaOH solution. Carbon dioxide is selectively removed from the gas stream, by chemical reaction, forming the product Na 2CO3. Scrubber off-gas, lean with regard to carbon dioxide but still rich with oxygen, is redirected through the spray tower for further stripping of DC and absorption of oxygen. Make-up NaOH is metered into the scrubbing solution sump on an as needed basis as directed by a feedback control loop programmed to maintain a scrubbing solution pH of 11.4-11.8. The spent NaOH solution is collected, then regenerated for reuse, in a batch process that requires relatively inexpensive hydrated lime (Ca(OH)2). A by-product of the regeneration step is an alkaline filter cake, which may have use in bio-solids stabilization. Given the enhanced gas transfer rates possible with chemical reaction, the required NaOH solution flow rate through the scrubber represents a fraction of the spray tower water flow rate. Further, isolation of the water being treated from the atmosphere (1), allows for an improvement in oxygen absorption efficiency by maintaining DN well below local saturation concentrations (2), minimizes building energy requirements related to heating and ventilation and (3), reduces the potential for pathogen transmittance. We report on the performance of a test scrubber evaluated over a range of NaOH solution temperatures, pH, packing irrigation rates, and gas stream compositions. We also describe our experience with the process in a pilot scale recirculating water (trout) production system.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hudson, David
2015-02-01
This report is a compilation of the groundwater sampling results from the Area 5 Radioactive Waste Management Site (RWMS) at the Nevada National Security Site, Nye County, Nevada. Groundwater samples from the aquifer immediately below the Area 5 RWMS have been collected and analyzed and static water levels have been measured in this aquifer since 1993. This report updates these data to include the 2014 results. Analysis results for leachate contaminants collected from the mixed-waste cell at the Area 5 RWMS (Cell 18) are also included. During 2014, groundwater samples were collected and static water levels were measured at threemore » wells surrounding the Area 5 RWMS. Groundwater samples were collected at wells UE5PW-1, UE5PW-2, and UE5PW-3 on March 11 and August 12, 2014, and static water levels were measured at each of these wells on March 10, June 2, August 11, and October 14, 2014. Groundwater samples were analyzed for the following indicators of contamination: pH, specific conductance, total organic carbon, total organic halides, and tritium. General water chemistry (cations and anions) was also measured. Results from samples collected in 2014 are within the limits established by agreement with the Nevada Division of Environmental Protection for each analyte. The data from the shallow aquifer indicate that there has been no measurable impact to the uppermost aquifer from the Area 5 RWMS, and there were no significant changes in measured groundwater parameters compared to previous years. Leachate from above the primary liner of Cell 18 drains into a sump and is collected in a tank at the ground surface. Cell 18 began receiving waste in January 2011. Samples were collected from the tank when the leachate volume approached the 3,000-gallon tank capacity. Leachate samples have been collected 16 times since January 2011. During 2014, samples were collected on February 25, March 5, May 20, August 12, September 16, November 11, and December 16. Each leachate sample was analyzed for toxicity characteristic contaminants and polychlorinated biphenyls (PCB). Beginning with the sample from July 31, 2013, pH and specific conductance were also measured. Leachate analysis results show no evidence of contamination. Results for toxicity characteristic contaminants are all below regulatory levels and analysis quantification limits. No quantifiable PCB levels were detected in any sample. Results for pH and specific conductance are also within expected ranges. After analysis, leachate was pumped from the collection tank and used in Cell 18 for dust control. The report contains an updated cumulative chronology for the Area 5 RWMS Groundwater Monitoring Program and a brief description of the site hydrogeology.« less
NASA Astrophysics Data System (ADS)
Perez, Debora; Okada, Elena; Aparicio, Virginia; Menone, Mirta; Costa, Jose Luis
2017-04-01
El Crespo stream is located inside a small watershed (52,000 Ha) which is only influenced by farming activities without urban or industrial impact. The watershed can be divided in two areas, the southern area (upstream), mainly composed of intensive crops and the northern area (downstream) used only for extensive livestock. In this sense, "El Crespo" stream in an optimal site for monitoring screening of pesticide residues. The objective of this work was to determine the seasonal and spatial variations of glyphosate (GLY), in surface waters of "El Crespo" stream. We hypothesized that in surface waters of "El Crespo" stream the levels of GLY vary depending of the season and rainfall events. The water sampling was carried out from October to June (2014-2015) in two sites: upstream (US) and downstream (DS), before and after rain events. The water samples were collected by triplicate in 1 L polypropylene bottles and stored at -20°C until analysis. GLY was extracted from unfiltered water samples with a buffer solution (100 mM Na2B4O7•10H2O/100 mM K3PO4, pH=9) and derivatized with 9-fluorenylmethylchloroformate (1 mg/mL in acetonitrile). Afterwards samples were analyzed using liquid chromatography coupled to a tandem mass spectrometer (UPLC-MS/MS). The detection limit (LD) was 0.1 μg/L and the quantification limit (QL) was 0.5 μg/L. The rainfall regime was obtained from the database of INTA Balcarce. GLY was detected in 92.3% of the analyzed samples. In the US site, were GLY is regularly applied, the highest GLY concentration was registered in October (2.15 ± 0.16 μg/L); from November to June, the GLY levels decreased from 1.97 ± 0.17 μg/L to
Ecological Monitoring and Compliance Program Fiscal Year 2002 Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
C. A. Wills
2002-12-01
The Ecological Monitoring and Compliance program, funded through the U.S. Department of Energy, National Nuclear Security Administration Nevada Operations Office, monitors the ecosystem of the Nevada Test Site (NTS) and ensures compliance with laws and regulations pertaining to NTS biota. This report summarizes the program's activities conducted by Bechtel Nevada (BN) during fiscal year 2002. Program activities included: (1) biological surveys at proposed construction sites, (2) desert tortoise compliance, (3) ecosystem mapping and data management, (4) sensitive species and unique habitat monitoring, and (5) biological monitoring at the HAZMAT Spill Center. Biological surveys for the presence of sensitive species andmore » important biological resources were conducted for 26 NTS projects. These projects have the potential to disturb a total of 374 acres. Thirteen of the projects were in desert tortoise habitat, and 13.38 acres of desert tortoise habitat were disturbed. No tortoises were found in or displaced from project areas, and no tortoises were accidentally injured or killed at project areas or along paved roads. Compilation of historical wildlife data continued this year in efforts to develop faunal distribution maps for the NTS. Photographs associated with the NTS ecological landform units sampled to create the NTS vegetation maps were cataloged for future retrieval and analysis. The list of sensitive plant species for which long-term population monitoring is scheduled was revised. Six vascular plants and five mosses were added to the list. Plant density estimates from ten populations of Astragalus beatleyae were collected, and eight known populations of Eriogonum concinnum were visited to assess plant and habitat status. Minimal field monitoring of western burrowing owl burrows occurred. A report relating to the ecology of the western burrowing owl on the Nevada Test Site was prepared which summarizes four years of data collected on this species' distribution, burrow use, reproduction, activity patterns, and food habits. Bat roost sites within seven buildings slated for demolition were identified, and a BN biologist was a contributing author of the Nevada Bat Conservation Plan published by the Nevada Bat Working Group. Thirty-three adult horses and five foals were counted this year. Six active raptor nests (two American kestrel, two Red-tailed hawk, and two Great-horned owl nests) were found and monitored this year. Selected wetlands and man-made water sources were monitored for physical parameters and wildlife use. No dead animals were observed this year in any plastic-lined sump. The chemical release test plan for one experiment at the HAZMAT Spill Center on Frenchman Lake playa was reviewed. Seasonal sampling of downwind and upwind transects near the spill center was conducted to document baseline conditions of biota.« less
Ecological Monitoring and Compliance Program Fiscal Year 2002 Report (Part Two of Two)
DOE Office of Scientific and Technical Information (OSTI.GOV)
C. A. Wills
2002-12-01
The Ecological Monitoring and Compliance program, funded through the U.S. Department of Energy, National Nuclear Security Administration Nevada Operations Office, monitors the ecosystem of the Nevada Test Site (NTS) and ensures compliance with laws and regulations pertaining to NTS biota. This report summarizes the program's activities conducted by Bechtel Nevada (BN) during fiscal year 2002. Program activities included: (1) biological surveys at proposed construction sites, (2) desert tortoise compliance, (3) ecosystem mapping and data management, (4) sensitive species and unique habitat monitoring, and (5) biological monitoring at the HAZMAT Spill Center. Biological surveys for the presence of sensitive species andmore » important biological resources were conducted for 26 NTS projects. These projects have the potential to disturb a total of 374 acres. Thirteen of the projects were in desert tortoise habitat, and 13.38 acres of desert tortoise habitat were disturbed. No tortoises were found in or displaced from project areas, and no tortoises were accidentally injured or killed at project areas or along paved roads. Compilation of historical wildlife data continued this year in efforts to develop faunal distribution maps for the NTS. Photographs associated with the NTS ecological landform units sampled to create the NTS vegetation maps were cataloged for future retrieval and analysis. The list of sensitive plant species for which long-term population monitoring is scheduled was revised. Six vascular plants and five mosses were added to the list. Plant density estimates from ten populations of Astragalus beatleyae were collected, and eight known populations of Eriogonum concinnum were visited to assess plant and habitat status. Minimal field monitoring of western burrowing owl burrows occurred. A report relating to the ecology of the western burrowing owl on the Nevada Test Site was prepared which summarizes four years of data collected on this species' distribution, burrow use, reproduction, activity patterns, and food habits. Bat roost sites within seven buildings slated for demolition were identified, and a BN biologist was a contributing author of the Nevada Bat Conservation Plan published by the Nevada Bat Working Group. Thirty-three adult horses and five foals were counted this year. Six active raptor nests (two American kestrel, two Red-tailed hawk, and two Great-horned owl nests) were found and monitored this year. Selected wetlands and man-made water sources were monitored for physical parameters and wildlife use. No dead animals were observed this year in any plastic-lined sump. The chemical release test plan for one experiment at the HAZMAT Spill Center on Frenchman Lake playa was reviewed. Seasonal sampling of downwind and upwind transects near the spill center was conducted to document baseline conditions of biota.« less
Migaszewski, Zdzisław M; Gałuszka, Agnieszka; Dołęgowska, Sabina
2016-12-01
A detailed hydrogeochemical study was performed in the Wiśniówka mining area (south-central Poland). This covered three acid pit bodies, historic tailings acid ponds, acid pools, and additionally two neighboring rivers. All these acid mine drainage (AMD) waters are characterized by the pH in the range of 1.7 (pools) to 3.5 (tailings ponds). The most interesting is the Podwiśniówka acid pit lake that shows a very low pH (2.2-2.5) and very high concentrations of SO 4 2- (2720-5460 mg/L), Fe (545-1140 mg/L), Al (86.2 mg/L), As (9603-24,883 μg/L), Co (1317-3458 μg/L), Cr (753-2047 μg/L), Cu (6307-18,879 μg/L), Ni (1168-3127 μg/L), and rare earth element (REE) (589-1341 μg/L). In addition, seeps that drain the Podwiśniówka mine tailings and partly aggregate piles form strong acid pools in the mining area. Along with these pools, in which As and REE contents reach 369,726 and 6288 μg/L, respectively, these waters are among the most distinctive As- and REE-rich AMD surface waters across the world. It is noteworthy that the Podwiśniówka acid pit lake and Wiśniówka Duża acid pit sump exhibit different element signatures and REE concentration patterns normalized to North American Composite Shale (NASC): the Podwiśniówka acid pit lake always shows a characteristic roof-shaped medium REE (MREE) profile with distinct enrichments in Gd, Eu, and Tb whereas the other one displays a step-shaped heavy REE (HREE) profile with positive Tb and Gd anomalies. The REE undergo fractionation during weathering and the subsequent leaching of dissolved and suspended fractions from rocks to acid water bodies where these and other elements are further fractionated by geochemical processes. This study shows that the individual REE have greater affinities for Mn, HREE for Fe and SO 4 2- , and only La and Ce for Al. This specific water geochemistry has enabled us to (i) pinpoint the location of AMD "hot spots" originated from quartzite mining and processing operations conducted by current and previous mining companies, (ii) predict the directions and effects of future strip mining for quartzites in the Wiśniówka Duża and Podwiśniówka open pits, and (iii) evaluate the potential impact of mining and processing effluents on the quality of rivers.
Ecological Monitoring and Compliance Program Fiscal Year 2001
DOE Office of Scientific and Technical Information (OSTI.GOV)
C. A. Wills
The Ecological Monitoring and Compliance program, funded through the U.S. Department of Energy, National Nuclear Security Administration Nevada Operations Office, monitors the ecosystem of the Nevada Test Site (NTS) and ensures compliance with laws and regulations pertaining to NTS biota. This report summarizes the program's activities conducted by Bechtel Nevada during fiscal year 2001. Program activities included: (1) biological surveys at proposed construction sites, (2) desert tortoise compliance, (3) ecosystem mapping and data management, (4) sensitive species and unique habitat monitoring, and (5) biological monitoring at the HAZMAT Spill Center. Biological surveys for the presence of sensitive species were conductedmore » for 23 NTS projects. Eleven sites were in desert tortoise habitat. These projects have the potential to disturb a total of 588 acres, where 568 acres of disturbance would be off-road driving. No tortoises were found in or displaced from project areas, and no tortoise s were accidentally injured or killed at project areas. One tortoise was crushed by a vehicle on a paved road. A topical report describing the classification of habitat types on the NTS was completed and distributed. The report is the culmination of three years of field vegetation mapping and the analysis of vegetation data from over 1,500 ecological landform units. Compilation of historical wildlife data was initiated. A long-term monitoring plan for important plant species that occur on the NTS was completed. Site-wide monitoring was conducted for the western burrowing owl, bat species of concern, wild horses, and raptor nests. Sixty-nine of 77 known owl burrows were monitored. As in previous years, some owls were present year round on the NTS. An overall decrease in active owl burrows was observed within all three ecoregions (Mojave Desert, Transition, Great Basin Desert) from October through January. An increase in active owl burrows was observed from mid March to early April. A total of 55 juvenile owls was detected from 11 breeding pairs. Pellet analysis of burrowing owls was completed which identified key prey species. A total of 272 bats, representing 10 bat species were captured in mist-nets at water sources in the Great Basin Desert ecoregion. Bats were detected with the Anabat II call-recording system at water sources and selected tunnel and mine entrances. Thirty-seven adult horses and 11 foals were counted this year. Two of the eleven foals observed last year survived to yearlings. Seven active raptor nests were found and monitored this year. These included two Great-horned Owl nests, three Barn Owl nests, and two Red-tailed Hawk nests. Selected wetlands and man-made water sources were monitored for physical parameters and wildlife use. No dead animals were observed this year in any plastic-lined sump. The chemical spill test plans for four experiments at the HAZMAT Spill Center were reviewed for their potential to impact biota downwind of spills on Frenchman Lake playa.« less
Hydrology of the San Luis Valley, south-central Colorado
Emery, P.A.; Boettcher, A.J.; Snipes, R.J.; Mcintyre, H.J.
1969-01-01
An investigation of the water resources of the Colorado part of the San Luis Valley was begun in 1966 by the U.S. Geological Survey, in cooperation with the Colorado Water Conservation Board. (See index map, fig. 1). The purpose of the investigation is to provide information for planning and implementing improved water-development and management practices. The major water problems in the San Luis Valley include (1) waterlogging, (2) waste of water by nonbeneficial evapotranspiration, (3) deterioration of ground-water chemical quality, and (4) failure of Colorado to deliver water to New Mexico and Texas in accordance with the Rio Grande Compact. This report describes the hydrologic environment, extent of water-resource development, and some of the problems related to that development. Information presented is based on data collected from 1966 to 1968 and on previous studies. Subsequent reports are planned as the investigation progresses. The San Luis Valley extends about 100 miles from Poncha Pass near the northeast corner of Saguache County, Colo., to a point about 16 miles south of the Colorado-New Mexico State line. The total area is 3,125 square miles, of which about 3,000 are in Colorado. The valley is nearly flat except for the San Luis Hills and a few other small areas. The Colorado part of the San Luis Valley, which is described in this report, has an average altitude of about 7,700 feet. Bounding the valley on the west are the San Juan Mountains and on the east the Sangre de Cristo Mountains. Most of the valley floor is bordered by alluvial fans deposited by streams originating in the mountains, the most extensive being the Rio Grande fan (see block diagram, fig. 2 in pocket). Most of the streamflow is derived from snowmelt from 4,700 square miles of watershed in the surrounding mountains. The northern half of the San Luis Valley is internally drained and is referred to as the closed basin. The lowest part of this area is known locally as the "sump." The remainder of the valley is drained by the Rio Grande and its tributaries. The climate of the San Luis Valley is arid, and a successful agricultural economy would not be possible without irrigation. It is characterized by cold winters, moderate summers, and much sunshine. The average annual precipitation on the valley floor ranges from 7 to 10 inches. More than half the precipitation occurs from July to September. Moisture deficiency in the valley is shown by the graph comparing pan evaporation and precipitation {fig. 3}. For the years 1961-67 average pan evaporation for the period April through September was 52.25 inches, but average precipitation for the period was only 5.02 inches. Average annual precipitation was 7.8 inches. Owing to the short growing season (90-120 days), crops a.re restricted mainly to barley, oats, potatoes, and other vegetables.
NASA Astrophysics Data System (ADS)
Kingdon, Andrew; Evans, David J.
2013-04-01
With the decline of the UK's remaining conventional reserves of natural gas and associated growth of imports, the lack of adequate storage capacity is a matter of concern for ensuring energy security year-round. In a number of countries, subsurface caverns for gas storage have been created by solution mining of massive halite deposits and similar storage facilities are likely to become an important part of the UK's energy infrastructure. Crucial to the economic viability of such facilities is the percentage of insoluble material within the halite intervals, which influences strongly the relationship between cavern sump and working volumes: successful development of these caverns is dependent upon maximising the efficiency of cavern design and construction. The purity of a massive halite sequence can only be assessed either by direct means (i.e. coring) or indirectly by downhole geophysical logs The use of conventional geophysical logs in subsurface exploration is well established but literature generally relies on a very low resolution tools with a typical vertical logging sample interval of 15 centimetres. This means that such tools provide, at best, a "blurred" view of the sedimentary successions penetrated by the borehole and that discrete narrow bands of insoluble material will not be identifiable or distinguishable from zones of "dirtier" halite with disseminated mud materials. In 2008, Halite-Energy Group (formerly Canatxx Gas Storage Ltd) drilled the Burrows Marsh #1 borehole and acquired resistivity borehole imaging (FMI) logs through the Triassic Preesall Halite in the Preesall Saltfield, NW England. In addition to near full circumferal imaging capability, rather than a single measurement per increment, FMI logs allows millimetre to centimetre scale imaging of sedimentary features, that is one to two orders of magnitude higher vertical resolution. After binary segmentation of the FMI images to achieve a simple halite-insoluble ("mud") separation these were subject to a filtering process to develop a detailed understanding of the halite sequence's insoluble content. The results were then calibrated, post-normalisation, by new laboratory determinations of the insoluble content of laterally equivalent samples of core from the nearby Arm Hill #1 borehole. The FMI logs provide a greater degree of resolution when compared to conventional geophysical logs. With the statistical analysis provided by this process, it further enhances the correlation between the logs and core and ultimately, the assessment of insoluble content. Despite the obvious increase in resolution, precise statistical quantification of the success of the borehole imaging technique is somewhat obfuscated by the absence of both FMI logs and continuous core in a single borehole. The acquisition parameters for these images are at the limits for the tools and therefore more noisy than those acquired in other lithologies or logging environments. The optimum acquisition parameters (in particular gain settings and logging speed), the nature of the filtering required to quantify the insoluble content and the effects of image noise on those calculations are discussed.
DWPF RECYCLE EVAPORATOR FLOWSHEET EVALUATION (U)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stone, M
2005-04-30
The Defense Waste Processing Facility (DWPF) converts the high level waste slurries stored at the Savannah River Site into borosilicate glass for long-term storage. The vitrification process results in the generation of approximately five gallons of dilute recycle streams for each gallon of waste slurry vitrified. This dilute recycle stream is currently transferred to the H-area Tank Farm and amounts to approximately 1,400,000 gallons of effluent per year. Process changes to incorporate salt waste could increase the amount of effluent to approximately 2,900,000 gallons per year. The recycle consists of two major streams and four smaller streams. The first majormore » recycle stream is condensate from the Chemical Process Cell (CPC), and is collected in the Slurry Mix Evaporator Condensate Tank (SMECT). The second major recycle stream is the melter offgas which is collected in the Off Gas Condensate Tank (OGCT). The four smaller streams are the sample flushes, sump flushes, decon solution, and High Efficiency Mist Eliminator (HEME) dissolution solution. These streams are collected in the Decontamination Waste Treatment Tank (DWTT) or the Recycle Collection Tank (RCT). All recycle streams are currently combined in the RCT and treated with sodium nitrite and sodium hydroxide prior to transfer to the tank farm. Tank Farm space limitations and previous outages in the 2H Evaporator system due to deposition of sodium alumino-silicates have led to evaluation of alternative methods of dealing with the DWPF recycle. One option identified for processing the recycle was a dedicated evaporator to concentrate the recycle stream to allow the solids to be recycled to the DWPF Sludge Receipt and Adjustment Tank (SRAT) and the condensate from this evaporation process to be sent and treated in the Effluent Treatment Plant (ETP). In order to meet process objectives, the recycle stream must be concentrated to 1/30th of the feed volume during the evaporation process. The concentrated stream must be pumpable to the DWPF SRAT vessel and should not precipitate solids to avoid fouling the evaporator vessel and heat transfer coils. The evaporation process must not generate excessive foam and must have a high Decontamination Factor (DF) for many species in the evaporator feed to allow the condensate to be transferred to the ETP. An initial scoping study was completed in 2001 to evaluate the feasibility of the evaporator which concluded that the concentration objectives could be met. This initial study was based on initial estimates of recycle concentration and was based solely on OLI modeling of the evaporation process. The Savannah River National Laboratory (SRNL) has completed additional studies using simulated recycle streams and OLI{reg_sign} simulations. Based on this work, the proposed flowsheet for the recycle evaporator was evaluated for feasibility, evaporator design considerations, and impact on the DWPF process. This work was in accordance with guidance from DWPF-E and was performed in accordance with the Technical Task and Quality Assurance Plan.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Beckman, John C.
2012-07-01
A water treatment system at a United States Environmental Protection Agency (USEPA) Superfund site impacted by radiological contaminants is used to treat water entering the site. The United States Army Corps of Engineers (USACE) is actively managing the remedial action for the USEPA using contracts to support the multiple activities on site. The site is where former gas mantle production facilities operated around the turn of the century. The manufacturing facilities used thorium ores to develop the mantles and disposed of off-specification mantles and ore residuals in the surrounding areas. During Site remedial actions, both groundwater and surface water comesmore » into contact with contaminated soils and must be collected and treated at an on-site treatment facility. The radionuclides thorium and radium with associated progeny are the main concern for treatment. Suspended solids, volatile organic compounds, and select metals are also monitored during water treatment. The water treatment process begins were water is pumped to a collection tank where debris and grit settle out. Stored water is pumped to a coagulant tank containing poly-aluminum chloride to collect dissolved solids. The water passes into a reaction tube where aspirated air is added or reagent added to remove Volatile Organic Compounds (VOC'S) by mass transfer and convert dissolved iron to a solid. The water enters the flocculent polymer tank to drop solids out. The flocculated water overflows to a fluidized bed contact chamber to increase precipitation. Flocculation is where colloids of material drop out of suspension and settle. The settled solids are periodically removed and disposed of as radioactive waste. The water is passed through filters and an ion exchange process to extract the radionuclides. Several million liters of water are processed each year from two water treatment plants servicing different areas of the remediation site. Ion exchange resin and filter material are periodically replaced and disposed of as radioactive waste. A total of 0.85 m{sup 3} of waste sludge per year requires disposal on average, in addition to another 6.6 m{sup 3} of waste cartridge filters. All water discharges are regulated by a state of New Jersey Pollutant Discharge Elimination System Permit implemented by the Federal Water Pollution Control Act (Clean Water Act). Laboratory analyses are required to satisfy requirements of the state NPDES permit. Specific monitoring parameters and discharge rates will be provided. Use of the water treatment systems drastically reduces the amount of contaminated water requiring solidification and water disposal to near zero. Millions of liters of potentially contaminated water from excavation activities is treated and released within permit limits. A small volume of solid radioactive waste (21 cubic meters) is generated annually from water treatment process operations. Management of ground and surface water is effectively controlled in remediation areas by the use of sumps, erosion control measures and pumping of water to storage vessels. Continued excavations can be made as water impacting the site is effectively controlled. (authors)« less
Sample Results from MCU Solids Outage
DOE Office of Scientific and Technical Information (OSTI.GOV)
Peters, T.; Washington, A.; Oji, L.
2014-09-22
Savannah River National Laboratory (SRNL) has received several solid and liquid samples from MCU in an effort to understand and recover from the system outage starting on April 6, 2014. SRNL concludes that the presence of solids in the Salt Solution Feed Tank (SSFT) is the likely root cause for the outage, based upon the following discoveries: A solids sample from the extraction contactor #1 proved to be mostly sodium oxalate; A solids sample from the scrub contactor#1 proved to be mostly sodium oxalate; A solids sample from the Salt Solution Feed Tank (SSFT) proved to be mostly sodium oxalate;more » An archived sample from Tank 49H taken last year was shown to contain a fine precipitate of sodium oxalate; A solids sample from ; A liquid sample from the SSFT was shown to have elevated levels of oxalate anion compared to the expected concentration in the feed. Visual inspection of the SSFT indicated the presence of precipitated or transferred solids, which were likely also in the Salt Solution Receipt Tank (SSRT). The presence of the solids coupled with agitation performed to maintain feed temperature resulted in oxalate solids migration through the MCU system and caused hydraulic issues that resulted in unplanned phase carryover from the extraction into the scrub, and ultimately the strip contactors. Not only did this carryover result in the Strip Effluent (SE) being pushed out of waste acceptance specification, but it resulted in the deposition of solids into several of the contactors. At the same time, extensive deposits of aluminosilicates were found in the drain tube in the extraction contactor #1. However it is not known at this time how the aluminosilicate solids are related to the oxalate solids. The solids were successfully cleaned out of the MCU system. However, future consideration must be given to the exclusion of oxalate solids into the MCU system. There were 53 recommendations for improving operations recently identified. Some additional considerations or additional details are provided below as recommendations. From this point on, IC-Anions analyses of the DSSHT should be part of the monthly routine analysis in order to spot negative trends in the oxalate leaving the MCU system. Care must be taken to monitor the oxalate content to watch for sudden precipitation of oxalate salts in the system; Conduct a study to optimize the cleaning strategy at ARP-MCU through decreasing the concentration or entirely eliminating the oxalic acid; The contents of the SSFT should remain unagitated. Routine visual observation should be maintained to ensure there is not a large buildup of solids. As water with agitation provided sufficient removal of the solids in the feed tank, it should be considered as a good means for dissolving oxalate solids if they are found in the future; Conduct a study to improve prediction of oxalate solubility in salt batch feed materials. As titanium and mercury have been found in various solids in this report, evaluate if either element plays a role in oxalate solubility during processing; Salt batch characterization focuses primarily on characterization and testing of unaltered Tank 21H material; however, non-typical feeds are developed through cleaning, washing, and/or sump transfers. As these solutions are processed through MCU, they may precipitate solids or reduce performance. Salt batch characterization and testing should be expanded to encompass a broader range of feeds that may be processed through ARPMCU.« less
Fate of Airborne Contaminants in Okefenokee National Wildlife Refuge
Winger, P.V.; Lasier, P.J.
1997-01-01
Designation of Okefenokee National Wildlife Refuge as a Class I Air Quality Area (given the highest level of protection possible from air pollutants under the Clean Air Act Amendments of 1977) affords mandatory protection of the Refuge's airshed through the permit-review process for planned developments. Rainfall is the major source of water to the swamp, and potential impacts from developments to the airshed are high. To meet management needs for baseline information, chemical contributions from atmospheric deposition and partitioning of anions and cations, with emphasis on mercury and lead, in the various matrices of the Swamp were determined between July 1993 and April 1995. Chemistry of rainfall was determined on an event basis from one site located at Refuge Headquarters. Field samples of surface water, pore water, floc and sediment were collected from four locations on the Refuge: Chesser Prairie, Chase Prairie, Durden Prairie, and the Narrows. A sediment core sample was collected from the Refuge interior at Bluff Lake for aging of mercury deposition. Rainfall was acidic (pH 4.8) with sulfate concentrations averaging 1.2 mg/L and nitrate averaging 0.8 mg/L. Lead in rainfall averaged 1 ?g/L and total and methylmercury concentrations were 11.7 ng/L and 0.025 ng/L, respectively. The drought of 1993 followed by heavy rains during the fall and winter caused a temporary alteration in the cycling and availability of trace-elements within the different matrices of the Swamp. Surface water was acidic (pH 3.8 to 4.1), dilute (specific conductance 35-60 ?S/cm), and highly organic (DOC 35-50 mg/L). Sediment and floc were also highly organic (>90%). Total mercury averaged 3.6 ng/L in surface water, 9.0 ng/L in pore water and about 170 ng/g in floc and sediments. Mercury bioaccumulated in the biota of the Refuge: fish fillets (Centrarchus macropterus, Esox niger, Lepomus gulosus and Amia calva) had >2 ?g/g dry weight, alligators (Alligator mississippiensis) >4 ?g/g dry weight in liver and kidney, and raccoons (Procyon lotor) >16 ?g/g dry weight in the liver and kidney. Lead averaged 1 ?g/L in rainfall, 6.6 ?g/L in surface water, 9.8 ?g/L in pore water, 12.3 ?g/g in floc and 12.5 ?g/g in sediments. Lead in fish muscle was ~0.1 ?g/g and >1.2 ?g/g in bone, alligator kidney had 1.5 ?g/g lead and liver had 3.8 ?g/g; raccoon kidney and liver averaged about 1 ?g/g. Historical patterns of mercury deposition based on 210Pb aging of the core sample showed mercury increased from pre-1800 concentrations of 500 ng/g in the 1950s, with a subsequent decline to current levels. Lead concentrations in the core sample followed a similar pattern as that of mercury. Okefenokee Swamp serves as a sump for the cations and anions deposited through rainfall. Although mercury and lead levels in the biota are not currently acutely hazardous, concentrations are high enough to cause adverse chronic effects on behavioral, physiological or reproductive functions of resident biota, especially piscivorous species. To protect trust resources associated with the Refuge, activities and developments in the airshed that have the potential to increase atmospheric contamination, especially for lead and mercury, should be curtailed.
Ecological Monitoring and Compliance Program Fiscal Year 2000 Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wills, C.A.
2000-12-01
The Ecological Monitoring and Compliance program, funded through the U.S. Department of Energy, Nevada Operations Office, monitors the ecosystem of he Nevada Test Site (NTS) and ensures compliance with laws and regulations pertaining to NTS biota. This report summarizes the program's activities conducted by Bechtel Nevada during fiscal year 2000. Program activities included: (1) biological surveys at proposed construction sites, (2) desert tortoise compliance,(3) ecosystem mapping, (4) sensitive species and unique habitat monitoring, and (5) biological monitoring at the HAZMAT Spill Center. Biological surveys for the presence of sensitive species were conducted for 24 NTS projects. Seventeen sites were inmore » desert tortoise habitat, and six acres of tortoise habitat were documented as being disturbed this year. No tortoises were found in or displaced from project areas, and no tortoises were accidentally injured or killed. A topical report describing the classification of habitat types o n the NTS was completed. The report is the culmination of three years of field vegetation mapping and the analysis of vegetation data from over 1,500 ecological landform units. A long-term monitoring plan for important plant species that occur on the NTS was completed. Sitewide inventories were conducted for the western burrowing owl, bat species of concern, wild horses, raptor nests, and mule deer. Fifty-nine of 69 known owl burrows were monitored. Forty-four of the known burrows are in disturbed habitat. As in previous years, some owls were present year round on the NTS. An overall decrease in active owl burrows was observed within all three ecoregions (Mojave Desert, Transition, Great Basin Desert) from October through January. An increase in active owl burrows was observed from mid-March to early April. A total of 45 juvenile owls was detected from eight breeding pairs. One nest burrow was detected in the Mojave Desert,one in the Great Basin Desert, and six in the Transition ecoregion. Seventy bats, representing four bat species of concern, were captured in mist-nets at water sources in the Great Basin Desert ecoregion. Bats were detected with the Anabat II call-recording system at selected tunnel and mine entrances verifying that some NTS mines and tunnels are used as bat roosts. Thirty-seven adult horses and 11 foals were counted this year. Four of the five foals observed last year have survived to yearlings. A monitoring plan for NTS horses was completed. Six active red-tailed hawk nests and 10 nestling red-tailed hawks were detected this year. Two spotlighting surveys for mule deer were conducted, each over three consecutive nights in October 1999 and August 2000. The mean sighting rate in October was 1.2 deer/10 kilometers (km) and 1.6 deer/10 km in August. Selected wetlands and man-made water sources were monitored for physical parameters and wildlife use. No dead animals were observed this year in any plastic-lined sump. Pahute Mesa Pond was confirmed to have vegetation,hydrology, and soil indicators that qualify the site as a jurisdictional wetland. The chemical spill test plan for one experiment at the HAZMAT Spill Center was reviewed for its potential to impact biota downwind of spills on Frenchman Lake playa.« less
Biodiesel Impact on Engine Lubricant Dilution During Active Regeneration of Aftertreatment Systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
He, X.; Williams, A.; Christensen, E.
Experiments were conducted with ultra low sulfur diesel (ULSD) and 20% biodiesel blends (B20) to compare lube oil dilution levels and lubricant properties for systems using late in-cylinder fuel injection for aftertreatment regeneration. Lube oil dilution was measured by gas chromatography (GC) following ASTM method D3524 to measure diesel content, by Fourier transform infrared (FTIR) spectrometry following a modified ASTM method D7371 to measure biodiesel content, and by a newly developed back-flush GC method that simultaneously measures both diesel and biodiesel. Heavy-duty (HD) engine testing was conducted on a 2008 6.7L Cummins ISB equipped with a diesel oxidation catalyst (DOC)more » and diesel particle filter (DPF). Stage one of engine testing consisted of 10 consecutive repeats of a forced DPF regeneration event. This continuous operation with late in-cylinder fuel injection served as a method to accelerate lube-oil dilution. Stage two consisted of 16 hours of normal engine operation over a transient test cycle, which created an opportunity for any accumulated fuel in the oil sump to evaporate. Light duty (LD) vehicle testing was conducted on a 2010 VW Jetta equipped with DOC, DPF and a NOx storage catalyst (NSC). Vehicle testing comprised approximately 4,000 miles of operation on a mileage-accumulation dynamometer (MAD) using the U.S. Environmental Protection Agency's Highway Fuel Economy Cycle because of the relatively low engine oil and exhaust temperatures, and high DPF regeneration frequency of this cycle relative to other cycles examined. Comparison of the lube oil dilution analysis methods suggests that D3524 does not measure dilution by biodiesel. The new back-flush GC method provided analysis for both diesel and biodiesel, in a shorter time and with lower detection limit. Thus all lube oil dilution results in this paper are based on this method. Analysis of the HD lube-oil samples showed only 1.5% to 1.6% fuel dilution for both fuels during continuous operation under DPF regeneration events. During the second stage of HD testing, the ULSD lube-oil dilution levels fell from 1.5% to 0.8%, while for B20, lube-oil dilution levels fell from 1.6% to 1.0%, but the fuel in the oil was 36% biodiesel. For the LD vehicle tests, the frequency of DPF regeneration events was observed to be the same for both ULSD and B20. No significant difference between the two fuels' estimated soot loading was detected by the engine control unit (ECU), although a 23% slower rate of increase in differential pressure across DPF was observed with B20. It appears that the ECU estimated soot loading is based on the engine map, not taking advantage of the lower engine-out particulate matter from the use of biodiesel. After 4,000 miles of LD vehicle operation with ULSD, fuel dilution in the lube-oil samples showed total dilution levels of 4.1% diesel. After 4,000 miles of operation with B20, total fuel in oil dilution levels were 6.7% consisting of 3.6% diesel fuel and 3.1% biodiesel. Extrapolation to the 10,000-mile oil drain interval with B20 suggests that the total fuel content in the oil could reach 12%, compared to 5% for operation on ULSD. Analysis of the oil samples also included measurement of total acid number, total base number, viscosity, soot, metals and wear scar; however, little difference in these parameters was noted.« less
Measuring Thermal Conductivity and Moisture Absorption of Cryo-Insulation Materials
NASA Technical Reports Server (NTRS)
Lambert, Michael A.
1998-01-01
NASA is seeking to develop thermal insulation material systems suitable for withstanding both extremely high temperatures encountered during atmospheric re-entry heating and aero- braking maneuvers, as well as extremely low temperatures existing in liquid fuel storage tanks. Currently, materials used for the high temperature insulation or Thermal Protection System (TPS) are different from the low temperature, or cryogenic insulation. Dual purpose materials are necessary to the development of reusable launch vehicles (RLV). The present Space Shuttle (or Space Transportation System, STS) employs TPS materials on the orbiter and cryo-insulation materials on the large fuel tank slung under the orbiter. The expensive fuel tank is jettisoned just before orbit is achieved and it burns up while re-entering over the Indian Ocean. A truly completely reusable launch vehicle must store aR cryogenic fuel internally. The fuel tanks will be located close to the outer surface. In fact the outer skin of the craft will probably also serve as the fuel tank enclosure, as in jet airliners. During a normal launch the combined TPS/cryo-insulation system will serve only as a low temperature insulator, since aerodynamic heating is relatively minimal during ascent to orbit. During re-entry, the combined TPS/cryo-insulation system will serve only as a high temperature insulator, since all the cryogenic fuel will have been expended in orbit. However, in the event of an.aborted launch or a forced/emergency early re-entry, the tanks will still contain fuel, and the TPS/cryo-insulation will have to serve as both low and high temperature insulation. Also, on long duration missions, such as to Mars, very effective cryo-insulation materials are needed to reduce bod off of liquid propellants, thereby reducing necessary tankage volume, weight, and cost. The conventional approach to obtaining both low and high temperature insulation, such as is employed for the X-33 and X-34 spacecraft, is to use separate TPS and cryo-insulation materials, which are connected by means of adhesives or stand-offs (spacers). Three concepts are being considered: (1) the TPS is bonded directly to the cryo-insulation which, in turn, is bonded to the exterior of the tank, (2) stand-offs are used to make a gap between the TPS and the cryo-insulation, which is bonded externally to the tank, (3) TPS is applied directly or with stand-offs to the exterior so the tank, and cryo-insulation is applied directly to the interior of the tank. Many potential problems are inherent in these approaches. For example, mismatch between coefficients of thermal expansion of the TPS and cryo-insulation, as well as aerodynamic loads, could lead to failure of the bond. Internal cryo-insulation must be prevent from entering the sump of the fuel turbo-pump. The mechanical integrity of the stand-off structure (if used) must withstand multiple missions. During ground hold (i.e., prior to launch) moisture condensation must be minimized in the gap between the cryo-insulation and the TPS. The longer term solution requires the development of a single material to act as cryo- insulation during ground hold and as TPS during re-entry. Such a material minimizes complexity and weight while improving reliability and reducing cost.
NASA Technical Reports Server (NTRS)
Hendricks, R. C.; Steinetz, B. M.
2006-01-01
The leading Aeronautics program within NASA is the High Speed Research Program (HSR). The HSR program's highest priorities are high pay-off technologies for airframe and propulsion systems required for a high speed civil transport (HSCT). These priorities have been developed collaboratively with NASA, FAA and the US Industry (Boeing-McDonnell Douglas, Pratt & Whitney and General Electric). Phase one of the HSR program started on 1990, and concentrated on the environmental challenges of minimizing NOx and noise. The first program goal is to reduce the NOx emission index to less than 5 (Concord NOx index is 20 and is unacceptable), in order to have little impact on the earth's ozone layer. The second goal is to reduce noise levels to FAR Stage 3 (or better), comparable to those of subsonic aircraft (far below the Concorde noise levels that require exemptions form less stringent standards). This requirement greatly impacts the nozzle design increasing its length and complexity and poses unique sealing challenges. Phase two started in 1993 and initiated work on the technologies required for an economical HSCT. Materials technologies under development include a ceramic-matrix-composite combustion liner, lightweight materials for the nozzle, as well long-life turbomachinery disk and blade alloys. Other required materials are being developed under the DOD-IHPTET program, where there is close cooperation. Economic goals translate into the development of technologies for tri-class service, 5000 nautical mile range aircraft with a ticket price no more than 20% over the subsonic ticket price. The potential market could be as large as 1500 aircraft, according to a Boeing study. Technology alone will not enable this airplane, yet without enabling technologies "on the shelf", it will not occur. The HSCT engine will be the largest engine ever built and operate at maximum conditions for long periods of time posing a number of challenges. The HSR engine mission requires that rotating equipment stay at take-off condition temperatures for hours not minutes per flight. Hence rotating equipment and seals must operate for many thousands of hours at extreme temperatures. It is anticipated that the nozzle will be 12 feet long and roughly 4 ft. by 5 ft. in cross-section with a nominal airflow of 800 lbs/sec. The complex function of the nozzle (including an ejector for noise attenuation) combined with long life place new demands on nozzle seal design. Three inlet configurations are under consideration with attendant sealing challenges, as will be illustrated herein. Four of these engines are required to propel a 5000 nautical mile class vehicle which demand that component reliability be at the highest possible level. In response, an HSR seals session was implemented as a part of the 1997-Seals and Secondary Flow Workshop. Overview presentations were given for each of the following areas: inlet, turbomachinery, combustor and nozzle. The HSCT seal issues center on durability and efficiency of rotating equipment seals (including brush seals), structural seals (including rope seals and other advanced concepts), and high-speed bearing and sump seals. Tighter clearances, propulsion system size and thermal requirements represent extremes that challenge the component designers. This document provides an initial step toward defining HSR seal needs. The overview for HSR seal designs includes, defining seal objectives, summarizing sealing and materials requirements, presenting relevant seal cross-sections, and identifying technology needs for the HSR office.
Paulson, Anthony J.; Dinicola, Richard S.; Noble, Marlene A.; Wagner, Richard J.; Huffman, Raegan L.; Moran, Patrick W.; DeWild, John F.
2012-01-01
The majority of filtered total mercury in the marine water of Sinclair Inlet originates from salt water flowing from Puget Sound. About 420 grams of filtered total mercury are added to Sinclair Inlet each year from atmospheric, terrestrial, and sedimentary sources, which has increased filtered total mercury concentrations in Sinclair Inlet (0.33 nanograms per liter) to concentrations greater than those of the Puget Sound (0.2 nanograms per liter). The category with the largest loading of filtered total mercury to Sinclair Inlet included diffusion of porewaters from marine sediment to the water column of Sinclair Inlet and discharge through the largest stormwater drain on the Bremerton naval complex, Bremerton, Washington. However, few data are available to estimate porewater and stormwater releases with any certainty. The release from the stormwater drain does not originate from overland flow of stormwater. Rather total mercury on soils is extracted by the chloride ions in seawater as the stormwater is drained and adjacent soils are flushed with seawater by tidal pumping. Filtered total mercury released by an unknown freshwater mechanism also was observed in the stormwater flowing through this drain. Direct atmospheric deposition on the Sinclair Inlet, freshwater discharge from creek and stormwater basins draining into Sinclair Inlet, and saline discharges from the dry dock sumps of the naval complex are included in the next largest loading category of sources of filtered total mercury. Individual discharges from a municipal wastewater treatment plant and from the industrial steam plant of the naval complex constituted the loading category with the third largest loadings. Stormwater discharge from the shipyard portion of the naval complex and groundwater discharge from the base are included in the loading category with the smallest loading of filtered total mercury. Presently, the origins of the solids depositing to the sediment of Sinclair Inlet are uncertain, and consequently, concentrations of sediments can be qualitatively compared only to total mercury concentrations of solids suspended in the water column. Concentrations of total mercury of suspended solids from creeks, stormwater, and even wastewater effluent discharging into greater Sinclair Inlet were comparable to concentrations of solids suspended in the water column of Sinclair Inlet. Concentrations of total mercury of suspended solids were significantly lower than those of marine bed sediment of Sinclair Inlet; these suspended solids have been shown to settle in Sinclair Inlet. The settling of suspended solids in the greater Sinclair Inlet and in Operable Unit B Marine of the naval complex likely will result in lower concentrations of total mercury in sediments. Such a decrease in total mercury concentrations was observed in the sediment of Operable Unit B Marine in 2010. However, total mercury concentrations of solids discharged from several sources from the Bremerton naval complex were higher than concentrations in sediment collected from Operable Unit B Marine. The combined loading of solids from these sources is small compared to the amount of solids depositing in OU B Marine. However, total mercury concentration in sediment collected at a monitoring station just offshore one of these sources, the largest stormwater drain on the Bremerton naval complex, increased considerably in 2010. Low methylmercury concentrations were detected in groundwater, stormwater, and effluents discharged from the Bremerton naval complex. The highest methylmercury concentrations were measured in the porewaters of highly reducing marine sediment in greater Sinclair Inlet. The marine sediment collected off the largest stormwater drain contained low concentrations of methylmercury in porewater because these sediments were not highly reducing.
Ground-water resources of the Wind River Indian Reservation, Wyoming
McGreevy, Laurence J.; Hodson, Warren Gayler; Rucker, Samuel J.
1969-01-01
The area of this investigation is in the western part of the Wind River Basin and includes parts of the Absaroka, Washakie, Wind River, and Owl Creek Mountains. The purposes of the study were to determine the general hydrologic properties of the rocks in the area and the occurrence and quality c f the water in them. Structurally, the area is a downfolded basin surrounded by upfolded mountain ranges. Igneous and metamorphic rocks of Precambrian age are exposed in the mountains: folded sedimentary rocks representing all geologic periods, except the Silurian, crop out along the margins of the basin; and relatively flat-lying Tertiary rocks are at the surface in the central part of the basin. Surficial sand and gravel deposits of Quaternary age occur along streams and underlie numerous terraces throughout the basin. The potential yield and quality of water from most rocks in the area are poorly known, but estimates are possible, based on local well data and on data concerning similar rocks in nearby areas. Yields of more than 1,000 gpm are possible from the rocks comprising the Bighorn Dolomite (Ordovician), Darby Formation (Devonian), Madison Limestone (Mississippian), and Tensleep Sandstone (Pennsylvanian). Total dissolved solids in the water range from about 300 to 3,000 ppm. Yields of as much as several hundred gallons per minute are possible from the Nugget Sandstone (Jurassic? and Triassic?). Yields of 20 gpm or more are possible from the Crow Mountain Sandstone (Triassic) and Sundance Formation (Jurassic). Dissolved solids are generally high but are less than 1,000 ppm near outcrops in some locations. The Cloverly and Morrison (Cretaceous and Jurassic), Mesaverde (Cretaceous) and Lance(?) (Cretaceous) Formations may yield as much as several hundred gallons per minute, but most wells in Cretaceous rocks yield less than 20 gpm. Dissolved solids generally range from 1,000 to 5,000 ppm but may be higher. In some areas, water with less than 1,000 ppm dissolved solids may be available from the Cloverly and Morrison Formations. Tertiary rocks yield a few to several hundred gallons per minute and dissolved solids generally range from 1,000 to 5,000 ppm. Wells in the Wind River Formation (Eocene) yield about 1.-500 gpm of water having dissolved solids of about 200-5,000 ppm. Yields of a few to several hundred gallons per minute are available from alluvium (Quaternary). Dissolved solids range from about 200 to 5,000 ppm. Many parts of the Wind River Irrigation Project have become waterlogged. The relation of drainage problems to geology and the character and thickness of rocks in the irrigated areas are partly defined by sections drawn on the basis of test drilling. The drainage-problem areas are classified according to geologic similarities into five general groups: flood plains, terraces, underfit-stream valleys, slopes, and transitional areas. Drainage can be improved by open drains, buried drains, relief wells, and pumped wells or by pumping from sumps or drains. The methods that will be most successful depend on the local geologic and hydrologic conditions. In several areas, the most effective means of relieving the drainage problem would be to reduce the amount of infiltration of water by lining canals and ditches and by reducing irrigation water applications to the optimum. Water from underground storage in alluvium could supplement water from surface storage in some areas. A few thousand acre-feet of water per square mile are in storage in some of the alluvium. The use of both surface and underground storage would reduce the need for additional surface-storage facilities and also would alleviate drainage problems in the irrigated areas.
Horwatich, Judy A.; Bannerman, Roger T.
2012-01-01
A hydrodynamic-settling device was installed in 2004 to treat stormwater runoff from a roof and parking lot located at the Water Utility Administration Building in Madison, Wis. The U.S. Geological Survey, in cooperation with the Wisconsin Department of Natural Resources, the City of Madison, cities in the Waukesha Permit Group, Hydro International, Earth Tech, Inc., National Sanitation Foundation International, and the U.S. Environmental Protection Agency, monitored the device from November 2005 through September 2006 to evaluate it as part of the U.S. Environmental Protection Agency's Environmental Technology Verification Program. Twenty-three runoff events monitored for flow volume and water quality at the device's inlet and outlet were used to calculate the percentage of pollutant reduction for the device. The geometric mean concentrations of suspended sediment (SS), "adjusted" total suspended solids (TSS), total phosphorus (TP), dissolved phosphorus (DP), total recoverable zinc (TZn), and total recoverable copper (TCu) measured at the inlet were 107 mg/L (milligrams per liter), 92 mg/L, 0.17 mg/L, 0.05 mg/L, 38 μg/L (micrograms per liter), and 12 μg/L, respectively, and these concentrations are in the range of values observed in stormwater runoff from other parking lots in Wisconsin and Michigan. Efficiency of the settling device was calculated using the efficiency ratio and summation of loads (SOL) methods. Using the efficiency ratio method, the device reduced concentrations of SS, and DP, by 19, and 15, percent, respectively. Using the efficiency ratio method, the device increased "adjusted" TSS and TZn concentrations by 5 and 19, respectively. Bypass occurred for 3 of the 23 runoff events used in this assessment, and the bypass flow and water-quality concentrations were used to determine the efficiency of the bypass system. Concentrations of SS, "adjusted" TSS, and DP were reduced for the system by 18, 5, and 18, respectively; however, TZn increased by 5 percent. Some of the TSS concentrations were "adjusted" to add the particles that remained on the sieves during sample processing. The loads of SS, "adjusted" TSS, and DP were reduced using the SOL method for the settling device by 38, 9, and 19 percent, respectively, and TZn increased by 13 percent. For the bypass system, the loads of SS, "adjusted" TSS, and DP had percentage reductions of 39, 12, 22, respectively, however TZn increased by 4 percent. The SOL method produced percentage reductions for SS and 'adjusted" TSS that were twice those for the efficiency ratio method. Removing the two large runoff events on August 23 and 24, 2006, from the SOL calculation brought the reduction for SS down to 16 and increased "adjusted" TSS by 4 percent. The two large runoff events were anomalies in that the runoff volumes and dissolved solids concentrations were greatly increased by overflow from an adjacent recycling facility. The SOL method was used to determine the percentage of SS load reduction for six different particle sizes for both the settling device and bypass system. Essentially no load reduction was observed for particles less than 125 micrometers (μm) in diameter, and about a 90-percent reduction occurred for particle sizes greater than 250 μm in diameter. The large removal efficiencies for particle sizes greater than 250 μm in diameter were further supported by the fact that more than 80 percent of the particle sizes trapped in the sump were greater than 250 μm in diameter. These results support the claim by the manufacturer of achieving a large percentage load reduction for particle sizes greater than 250 μm in diameter.
Waterfowl migration on Klamath Basin National Wildlife Refuges 1953-2001
Gilmer, David S.; Yee, Julie L.; Mauser, David M.; Hainline, James M.
2004-01-01
The Klamath Basin National Wildlife Refuge (NWR) complex, located in northeastern California and southern Oregon, is situated on a major Pacific Flyway migration corridor connecting waterfowl breeding grounds in the north with major wintering grounds in California and Mexico. The complex comprises five waterfowl refuges including Lower Klamath NWR, Tule Lake NWR, Upper Klamath NWR, Klamath Marsh NWR, and Clear Lake NWR, and one bald eagle refuge, Bear Valley NWR. Lower Klamath and Tule Lake NWRs are the largest refuges in the complex; historically, they supported some of the greatest autumn and spring concentrations of migrating waterfowl in North America. Starting in 1953, standardized waterfowl surveys from small aircraft have been conducted in autumn through spring. This report summarizes waterfowl migration activity (i.e., abundance, species composition, distribution on refuges, and chronology) over four time periods—the long-term (1953-2001), early (1953-76), recent (1977-2001), and the most recent (1998-2001)—to describe changing patterns of migration on Klamath Basin refuges from autumn 1953 to spring 2001.Over the long term, waterfowl abundance (birds per day) on the refuge complex averaged about 1.0 million in autumn and about 360,000 in spring. A record peak count of 5.8 million waterfowl was recorded September 24-25, 1958. Average abundance of autumn staging waterfowl for the refuge complex, after reaching record levels in the 1950s and early 1960s, began a decline that lasted until the 1980s. A gradual recovery occurred during the 1990s, but autumn abundance has not recovered to pre-1970 levels. In contrast to autumn, average spring abundance was generally lower in the early decades but has gradually increased through the 1990s, particularly on Lower Klamath NWR.Dabbling ducks represented an average of 68% of all waterfowl in autumn and 55% in spring for the long term. Northern pintail (Anas acuta) was dominant, representing 62% of all dabblers in autumn and 51% in spring. A significant decline in pintail abundance starting in the late 1950s altered waterfowl composition on Klamath Basin refuges. As pintail declined, other species such as mallard (Anas platyrhynchos) and green-winged teal (Anas crecca) increased in abundance. Although Arctic nesting geese, including white-fronted (Anser albifrons), cackling Canada (Branta canadensis minima), white geese (lesser snow [Chen caerulescens caerulescens], and Ross’s [Chen rossii]) have become less prominent in recent decades, they reached an historically high abundance during autumn in the 1960s and 1970s, particularly on Tule Lake NWR.Tule Lake NWR supported the highest average autumn waterfowl populations until surpassed by Lower Klamath NWR around 1980. During the recent period (1977-2001), Lower Klamath NWR accounted for 60% of all waterfowl using the refuge complex in autumn and 61% in spring. Habitat diversity and wetland productivity contributed to its greater waterfowl abundance. Tule Lake NWR supported the most geese over the long term, 79% in autumn and 66% in spring; however, total waterfowl abundance on this refuge in autumn has been in decline, likely because of reduced diversity and productivity of sumps in the refuge. Upper Klamath, Klamath Marsh, and Clear Lake NWRs accounted for less than 8% of total waterfowl use in autumn and spring but provided diverse habitats for migrants.Waterfowl use-days on Klamath Basin refuges typically peaked in mid-autumn, decreased as migrants passed through the basin, and then reached a lesser peak during spring passage. Waterfowl abundance reached a pronounced peak in autumn during the early period (1953-76), but spring peak buildup was much less pronounced. For the recent period the autumn peak was more subdued.Waterfowl abundance, species composition, and distribution on Klamath Basin refuges have fluctuated over the decades and have been influenced by events such as productivity on breeding grounds and habitat conditions on wintering grounds that cause shifts in migration patterns. A major challenge for the future appears to be the availability of adequate water for wetland management on Klamath Basin refuges.
Paulson, Anthony J.; Conn, Kathleen E.; DeWild, John F.
2013-01-01
Previous investigations examined sources and sinks of mercury to Sinclair Inlet based on historic and new data. This included an evaluation of mercury concentrations from various sources and mercury loadings from industrial discharges and groundwater flowing from the Bremerton naval complex to Sinclair Inlet. This report provides new data from four potential sources of mercury to Sinclair Inlet: (1) filtered and particulate total mercury concentrations of creek water during the wet season, (2) filtered and particulate total mercury releases from the Navy steam plant following changes in the water softening process and discharge operations, (3) release of mercury from soils to groundwater in two landfill areas at the Bremerton naval complex, and (4) total mercury concentrations of solids in dry dock sumps that were not affected by bias from sequential sampling. The previous estimate of the loading of filtered total mercury from Sinclair Inlet creeks was based solely on dry season samples. Concentrations of filtered total mercury in creek samples collected during wet weather were significantly higher than dry weather concentrations, which increased the estimated loading of filtered total mercury from creek basins from 27.1 to 78.1 grams per year. Changes in the concentrations and loading of filtered and particulate total mercury in the effluent of the steam plant were investigated after the water softening process was changed from ion-exchange to reverse osmosis and the discharge of stack blow-down wash began to be diverted to the municipal water-treatment plant. These changes reduced the concentrations of filtered and particulate total mercury from the steam plant of the Bremerton naval complex, which resulted in reduced loadings of filtered total mercury from 5.9 to 0.15 grams per year. Previous investigations identified three fill areas on the Bremerton naval complex, of which the western fill area is thought to be the largest source of mercury on the base. Studies of groundwater in the other two fill areas were conducted under worst-case higher high tidal conditions. A December 2011 study found that concentrations of filtered total mercury in the well in the fill area on the eastern boundary of the Bremerton naval complex were less than or equal to 11 nanograms per liter, indicating that releases from the eastern area were unlikely. In addition, concentrations of total mercury of solids were low (<3 milligrams per kilogram). In contrast, data from the November 2011 study indicated that the concentrations of filtered total mercury in the well located in the central fill area had tidally influenced concentrations of up to 500 nanograms per liter and elevated concentrations of total mercury of solids (29–41 milligrams per kilogram). This suggests that releases from this area, which has not been previously studied in detail, may be substantial. Previous measurements of total mercury of suspended solids in the dry dock discharges revealed high concentration of total mercury when suspended-solids concentrations were low. However, this result could have been owing to bias from sequential sampling during changing suspended‑solids concentrations. Sampling of two dry dock systems on the complex in a manner that precluded this bias confirmed that suspended-solids concentrations and total mercury concentrations of suspended solids varied considerably during pumping cycles. These new data result in revised estimates of solids loadings from the dry docks. Although most of the solids discharged by the dry docks seem to be recycled Operable Unit B Marine sediment, a total of about 3.2 metric tons of solids per year containing high concentrations of total mercury were estimated to be discharged by the two dry dock systems. A simple calculation, in which solids (from dry docks, the steam plant, and tidal flushing of the largest stormwater drain) are widely dispersed throughout Operable Unit B Marine, suggests that Bremerton naval complex solids would likely have little effect on Operable Unit B Marine sediments because of high concentrations of mercury already present in the sediment.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wurtz, Jeff
2016-08-01
Well ER-20-12 was drilled for the U.S. Department of Energy, Nevada National Security Administration Nevada Field Office in support of the Underground Test Area Activity. The well was drilled from October 2015 to January 2016 as an addition to the Central and Western Pahute Mesa corrective action units 101 and 102 the Phase II drilling program. Well ER-20-12 was identified based on recommendations of the Pahute Mesa Guidance Team as a result of anomalous tritium detections in groundwater samples collected from Well PM-3 in 2011 and 2013. The primary purpose of the well was to provide information on the hydrogeologymore » in the area downgradient of select underground tests on Western Pahute Mesa and define hydraulic properties in the saturated Tertiary volcanic rocks. The main 46.99-centimeter (cm) (18.5-inch [in.]) borehole was drilled to a depth of 765.14 meters (m) (2,510.3 ft) and the hole opened to 66.04 cm (26 in.); followed by the 50.80-cm (20-in.) surface casing, which was installed and sealed with cement; and a piezometer (p4) was set in the Timber Mountain welded-tuff aquifer (TMWTA) between the casing and the open borehole. The borehole was continued with a 46.99-cm (18.5-in.) drill bit to a depth of 1,326.53 m (4,352.16 ft), and an intermediate 24.44-cm (9.625-in.) casing was installed and sealed to 1,188.72 m (3,900.00 ft) A piezometer (p3) was installed across the Calico Hills zeolitic composite unit (CHZCM) (lava-flow aquifer [LFA]) in the annulus of the open borehole. Two additional piezometers were installed and completed between the intermediate casing and the borehole wall, one (p2) in the CHZCM and one (p1) in the Belted Range aquifer (BRA). The piezometers are set to monitor groundwater properties in the completed intervals. The borehole was continued with a 21.59-cm (8.5-in.) drill bit to a total depth of 1,384.80 m (4,543.33 ft), and the main completion 13.97-cm (5.5-in.) casing was installed in the open borehole across the Pre-Belted Range composite unit (PBRCM). Data collected during hole construction include composite drill cutting samples collected every 3.0 m (10 ft), geophysical logs, hydrophysical logs, percussion core samples, water-quality measurements (including tritium), and water-level measurements. The well penetrated 1,384.4 m (4,543.33 ft) of Tertiary volcanic rocks. The stratigraphy and lithology were generally as expected with one noted exception. A thick lava-flow and related ash-flow tuffs were identified as Calico Hills Formation (Th), and no Crater Flat units were noted. Additionally, many of the Thirsty Canyon and Timber Mountain units were thicker than expected. Fluid levels measured in the borehole during drilling are the following: (1) on November 2, 2015, Navarro measured the fluid level in the borehole at a depth of 492.33 m (1,615.25 ft) below ground surface (bgs); (2) Schlumberger and COLOG recorded fluid levels during geophysical logging on November 4 and 5, 2015, at a depth of 492.86 m (1,617 ft) and 492.25 m (1,615 ft) bgs, respectively; and (3) on December 4, 2015, COLOG and Navarro measured fluid level in the 20-in. casing with an open borehole to 1,326.54 m (4,352.16 ft) bgs at 575.77 m (1,889.00 ft) and 574.03 m (1,883.3 ft) bgs, respectively. These and subsequent water-level measurements indicate a potential head difference of greater than 76.2 m (250 ft) for groundwater in aquifers above and below the Upper Paintbrush confining unit (UPCU). As expected, tritium was occasionally measured above the Safe Drinking Water Act limit (20,000 picocuries per liter [pCi/L]). Lab analysis on four bailed samples and taken from the undeveloped well indicate that the tritium activities average approximately 36,545 pCi/L. All Fluid Management Plan (FMP) requirements for Well ER-20-12 were met. Analysis of monitoring samples and FMP confirmatory samples indicate that fluids generated during drilling at ER-20-12 met the FMP criteria for discharge to the lined sump and designated infiltration area. All sanitary and hydrocarbon waste generated was properly handled and disposed of.« less
Influence of fuel properties on internal nozzle flow development in a multi-hole diesel injector
DOE Office of Scientific and Technical Information (OSTI.GOV)
Torelli, Roberto; Som, Sibendu; Pei, Yuanjiang
Fuel physical properties are known to influence in-nozzle flow behavior, in turn affecting spray formation in internal combustion engines. A series of 3D simulations was performed to model the internal nozzle flow in a five-hole mini-sac diesel injector. The goal of the study was to evaluate the behavior of two gasoline-like fuels (full-range naphtha and light naphtha) and compare them against n-Dodecane, selected from a palette used as a diesel surrogate. Simulations were carried out using a multi-phase flow representation based on the mixture model assumption with the Volume of Fluid (VOF) method, and including cavitation effects by means ofmore » the Homogeneous Relaxation Model (HRM). Validated methodologies from our previous studies were employed to account for full needle motion. Detailed simulations revealed the influence of the fuel properties on injector performance, injected fuel energy and propensity to cavitation. The three fuels were compared with respect to global parameters such as mass flow rate and area contraction coefficients, and local parameters such as pressure and velocity distribution inside the sac and orifices. Parametric investigations were also performed to understand the fuel response to changes in the fuel injection temperature, injection pressure, and geometry details. Cavitation magnitude was observed to be strongly associated with the values of saturation pressure. Owing to their higher volatility, the two gasoline-like fuels were observed to cavitate more than n-Dodecane across all the investigated conditions. While at full needle lift cavitation was reduced for all fuels, during the injection transients the gasoline-like fuels showed more propensity to cavitate inside the orifice and seat regions. This is expected to have a profound influence on nozzle erosion. Although full-range and light naphtha have lower densities compared to n-Dodecane, owing to their lower viscosity, the mass flow rate differences between the naphtha fuels and n-Dodecane were small. In conclusion, the analysis of fuel energy content showed that the higher lower heating value (LHV) of light naphtha helped compensate for the slightly lower total delivered mass.« less
Influence of fuel properties on internal nozzle flow development in a multi-hole diesel injector
Torelli, Roberto; Som, Sibendu; Pei, Yuanjiang; ...
2017-05-31
Fuel physical properties are known to influence in-nozzle flow behavior, in turn affecting spray formation in internal combustion engines. A series of 3D simulations was performed to model the internal nozzle flow in a five-hole mini-sac diesel injector. The goal of the study was to evaluate the behavior of two gasoline-like fuels (full-range naphtha and light naphtha) and compare them against n-Dodecane, selected from a palette used as a diesel surrogate. Simulations were carried out using a multi-phase flow representation based on the mixture model assumption with the Volume of Fluid (VOF) method, and including cavitation effects by means ofmore » the Homogeneous Relaxation Model (HRM). Validated methodologies from our previous studies were employed to account for full needle motion. Detailed simulations revealed the influence of the fuel properties on injector performance, injected fuel energy and propensity to cavitation. The three fuels were compared with respect to global parameters such as mass flow rate and area contraction coefficients, and local parameters such as pressure and velocity distribution inside the sac and orifices. Parametric investigations were also performed to understand the fuel response to changes in the fuel injection temperature, injection pressure, and geometry details. Cavitation magnitude was observed to be strongly associated with the values of saturation pressure. Owing to their higher volatility, the two gasoline-like fuels were observed to cavitate more than n-Dodecane across all the investigated conditions. While at full needle lift cavitation was reduced for all fuels, during the injection transients the gasoline-like fuels showed more propensity to cavitate inside the orifice and seat regions. This is expected to have a profound influence on nozzle erosion. Although full-range and light naphtha have lower densities compared to n-Dodecane, owing to their lower viscosity, the mass flow rate differences between the naphtha fuels and n-Dodecane were small. In conclusion, the analysis of fuel energy content showed that the higher lower heating value (LHV) of light naphtha helped compensate for the slightly lower total delivered mass.« less
Ecological Monitoring and Compliance Program 2014 Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hall, Derek B.; Anderson, David C.; Greger, Paul D.
The Ecological Monitoring and Compliance Program (EMAC), funded through the U.S. Department of Energy, National Nuclear Security Administration Nevada Field Office (NNSA/NFO, formerly Nevada Site Office), monitors the ecosystem of the Nevada National Security Site (NNSS) and ensures compliance with laws and regulations pertaining to NNSS biota. This report summarizes the program’s activities conducted by National Security Technologies, LLC (NSTec), during calendar year 2014. Program activities included (a) biological surveys at proposed activity sites, (b) desert tortoise compliance, (c) ecosystem monitoring, (d) sensitive plant species monitoring, (e) sensitive and protected/regulated animal monitoring, and (f) habitat restoration monitoring. During 2014, allmore » applicable laws, regulations, and permit requirements were met, enabling EMAC to achieve its intended goals and objectives. Sensitive and protected/regulated species of the NNSS include 42 plants, 1 mollusk, 2 reptiles, 236 birds, and 27 mammals. These species are protected, regulated, or considered sensitive according to state or federal regulations and natural resource agencies and organizations. The desert tortoise (Gopherus agassizii) and the western yellow-billed cuckoo (Coccyzus americanus) are the only species on the NNSS protected under the Endangered Species Act, both listed as threatened. However, only one record of the cuckoo has ever been documented on the NNSS, and there is no good habitat for this species on the NNSS. It is considered a rare migrant. Biological surveys for the presence of sensitive and protected/regulated species and important biological resources on which they depend were conducted for 18 projects. A total of 199.18 hectares (ha) was surveyed for these projects. Sensitive and protected/regulated species and important biological resources found during these surveys included a predator burrow, one sidewinder rattlesnake (Crotalus cerastes), two mating speckled rattlesnakes (Crotalus mitchellii), and several species of cacti. NSTec provided to project managers a written summary report of all survey findings and mitigation recommendations, where applicable. Of the 18 projects on the NNSS, 15 occurred within the range of the threatened desert tortoise. Approximately 2.19 ha of desert tortoise habitat were disturbed. No desert tortoises were accidentally injured or killed by project activities, and no tortoises were killed by vehicles. On 13 occasions, tortoises were moved off the road and out of harm’s way. Six tortoises were found and transmitters attached as part of an approved study to assess impacts of vehicles on tortoises on the NNSS. NSTec biologists continued to monitor 37 juvenile desert tortoises as part of a collaborative effort to study survival and temperament of translocated animals. From 1978 until 2013, there has been an average of 11.2 wildland fires per year on the NNSS with an average of about 83.7 ha burned per fire. There were no wildland fires documented on the NNSS during 2014. Results from the wildland fuel surveys showed a very low risk of wildland fire due to reduced fuel loads caused by limited natural precipitation. Limited reptile trapping and reptile roadkill surveys were conducted to better define species distribution on the NNSS. Sixteen reptiles were trapped representing five species. Combined with data from 2013, 183 road kills were detected, representing 11 snake and 8 lizard species. Selected natural water sources were monitored to assess trends in physical and biological parameters, and one new water source was found. Wildlife use at five water troughs and four radiologically contaminated sumps was documented using motion-activated cameras. As part of the statewide effort to disseminate information throughout the botanical community, NSTec prepared a shape file with site-specific data for all 17 sensitive plants on the NNSS and provided it to the Nevada Natural Heritage Program for inclusion in their statewide database. No field surveys were conducted this year for sensitive plants on the NNSS due to poor growing conditions. Surveys of sensitive and protected/regulated animals during 2014 focused on winter raptors, bats, wild horses (Equus caballus), mule deer (Odocoileus hemionus), desert bighorn sheep (Ovis Canadensis nelsoni), and mountain lions (Puma concolor). Two permanent, long-term winter raptor survey routes were established and sampled in January and February. A total of 27 raptors representing 4 species were observed. The wild horse population increased from 30 to 41, with several yearlings recruiting into the population, possibly due to the death of a mountain lion known to prey on horse foals. Mule deer abundance and density measured with standardized deer surveys was similar to 2013 and appears to be stable. Desert bighorn sheep, including rams, ewes, and lambs, were detected using motion-activated cameras at four water sources. There are plans to conduct helicopter surveys to census the population during September 2015 and then capture and radio-collar up to 20 sheep during November 2015. Over 150 sheep scat samples have been collected for genetic analysis to try to determine how sheep on the NNSS are related to surrounding sheep populations. Information is presented about bird mortalities, Migratory Bird Treaty Act compliance, and a summary of nuisance animals and their control on the NNSS. A total of 93 mountain lion images (i.e., photographs or video clips) were taken during 220,379 camera hours at 16 of 32 sites sampled and another 11,946 images of at least 29 species other than mountain lions were taken as well. A mountain lion telemetry study continued in 2014. NNSS7 was tracked from January 1 to November 15 using a global positioning system satellite transmitter. He consumed 21 mule deer, 17 desert bighorn sheep, 1 juvenile bobcat, and 3 coyotes. Mule deer were primarily taken in the summer and fall. No new mountain lions were captured. A minimum of four adult lions (two males, two females), a subadult male, and three kittens were known to inhabit the NNSS during 2014. Two previously revegetated sites on the NNSS and one on the Tonopah Test Range (TTR) were monitored in 2014. The cover cap on the U-3ax/bl disposal unit, revegetated in 2000, and the 92-Acre Site at the Area 5 Radioactive Waste Management Complex, revegetated in 2011, were the restoration sites monitored on the NNSS. The Corrective Action Unit 407 Rollercoaster RADSAFE site, revegetated in 2000, was the restoration site monitored on the TTR. Plant cover and density were recorded at all sites except U-3ax/bl (qualitative monitoring), and reclamation success standards were evaluated, where applicable.« less