DOE Office of Scientific and Technical Information (OSTI.GOV)
Lavoie, Caroline; Higgins, Jane; Bissonnette, Jean-Pierre
2012-12-01
Purpose: To compare the relative accuracy of 2 image guided radiation therapy methods using carina vs spine as landmarks and then to identify which landmark is superior relative to tumor coverage. Methods and Materials: For 98 lung patients, 2596 daily image-guidance cone-beam computed tomography scans were analyzed. Tattoos were used for initial patient alignment; then, spine and carina registrations were performed independently. A separate analysis assessed the adequacy of gross tumor volume, internal target volume, and planning target volume coverage on cone-beam computed tomography using the initial, middle, and final fractions of radiation therapy. Coverage was recorded for primary tumormore » (T), nodes (N), and combined target (T+N). Three scenarios were compared: tattoos alignment, spine registration, and carina registration. Results: Spine and carina registrations identified setup errors {>=}5 mm in 35% and 46% of fractions, respectively. The mean vector difference between spine and carina matching had a magnitude of 3.3 mm. Spine and carina improved combined target coverage, compared with tattoos, in 50% and 34% (spine) to 54% and 46% (carina) of the first and final fractions, respectively. Carina matching showed greater combined target coverage in 17% and 23% of fractions for the first and final fractions, respectively; with spine matching, this was only observed in 4% (first) and 6% (final) of fractions. Carina matching provided superior nodes coverage at the end of radiation compared with spine matching (P=.0006), without compromising primary tumor coverage. Conclusion: Frequent patient setup errors occur in locally advanced lung cancer patients. Spine and carina registrations improved combined target coverage throughout the treatment course, but carina matching provided superior combined target coverage.« less
Electron intensity modulation for mixed-beam radiation therapy with an x-ray multi-leaf collimator
NASA Astrophysics Data System (ADS)
Weinberg, Rebecca
The current standard treatment for head and neck cancer at our institution uses intensity-modulated x-ray therapy (IMRT), which improves target coverage and sparing of critical structures by delivering complex fluence patterns from a variety of beam directions to conform dose distributions to the shape of the target volume. The standard treatment for breast patients is field-in-field forward-planned IMRT, with initial tangential fields and additional reduced-weight tangents with blocking to minimize hot spots. For these treatment sites, the addition of electrons has the potential of improving target coverage and sparing of critical structures due to rapid dose falloff with depth and reduced exit dose. In this work, the use of mixed-beam therapy (MBT), i.e., combined intensity-modulated electron and x-ray beams using the x-ray multi-leaf collimator (MLC), was explored. The hypothesis of this study was that addition of intensity-modulated electron beams to existing clinical IMRT plans would produce MBT plans that were superior to the original IMRT plans for at least 50% of selected head and neck and 50% of breast cases. Dose calculations for electron beams collimated by the MLC were performed with Monte Carlo methods. An automation system was created to facilitate communication between the dose calculation engine and the treatment planning system. Energy and intensity modulation of the electron beams was accomplished by dividing the electron beams into 2x2-cm2 beamlets, which were then beam-weight optimized along with intensity-modulated x-ray beams. Treatment plans were optimized to obtain equivalent target dose coverage, and then compared with the original treatment plans. MBT treatment plans were evaluated by participating physicians with respect to target coverage, normal structure dose, and overall plan quality in comparison with original clinical plans. The physician evaluations did not support the hypothesis for either site, with MBT selected as superior in 1 out of the 15 head and neck cases (p=1) and 6 out of 18 breast cases (p=0.95). While MBT was not shown to be superior to IMRT, reductions were observed in doses to critical structures distal to the target along the electron beam direction and to non-target tissues, at the expense of target coverage and dose homogeneity.
Treuer, Harald; Hoevels, Moritz; Luyken, Klaus; Visser-Vandewalle, Veerle; Wirths, Jochen; Kocher, Martin; Ruge, Maximilian
2015-06-01
Stereotactic radiosurgery with an adapted linear accelerator (linac-SRS) is an established therapy option for brain metastases, benign brain tumors, and arteriovenous malformations. We intended to investigate whether the dosimetric quality of treatment plans achieved with a CyberKnife (CK) is at least equivalent to that for linac-SRS with circular or micromultileaf collimators (microMLC). A random sample of 16 patients with 23 target volumes, previously treated with linac-SRS, was replanned with CK. Planning constraints were identical dose prescription and clinical applicability. In all cases uniform optimization scripts and inverse planning objectives were used. Plans were compared with respect to coverage, minimal dose within target volume, conformity index, and volume of brain tissue irradiated with ≥ 10 Gy. Generating the CK plan was unproblematic with simple optimization scripts in all cases. With the CK plans, coverage, minimal target volume dosage, and conformity index were significantly better, while no significant improvement could be shown regarding the 10 Gy volume. Multiobjective comparison for the irradiated target volumes was superior in the CK plan in 20 out of 23 cases and equivalent in 3 out of 23 cases. Multiobjective comparison for the treated patients was superior in the CK plan in all 16 cases. The results clearly demonstrate the superiority of the irradiation plan for CK compared to classical linac-SRS with circular collimators and microMLC. In particular, the average minimal target volume dose per patient, increased by 1.9 Gy, and at the same time a 14% better conformation index seems to be an improvement with clinical relevance.
Oldenburg, Catherine E; Amza, Abdou; Kadri, Boubacar; Nassirou, Beido; Cotter, Sun Y; Stoller, Nicole E; West, Sheila K; Bailey, Robin L; Porco, Travis C; Gaynor, Bruce D; Keenan, Jeremy D; Lietman, Thomas M
2018-02-01
Repeated oral azithromycin distribution targeted only to children has proven effective in reducing the ocular Chlamydia that causes trachoma. Here, we assess whether an enhanced coverage target of at least 90% of children is superior to the World Health Organization recommendation of at least 80%. Twenty-four trachoma-endemic communities in Matamèye, Niger, were randomized to a single day of azithromycin distribution aiming for at least 80% coverage or up to 4 days of treatment and > 90% coverage of children under age 12. All distributions were biannual. Children < 5 years of age and adults > 15 years were monitored for ocular Chlamydia infection by polymerase chain reaction every 6 months for 36 months in children and at baseline and 36 months in adults. Ocular Chlamydia prevalence in children decreased from 24.9% (95% confidence interval [CI] 15.9-33.8%) to 4.4% (95% CI 0.6-8.2%, P < 0.001) at 36 months in the standard coverage arm and from 15.6% (95% CI 10.0-21.2%) to 3.3% (95% CI 1.0-5.5%; P < 0.001) in the enhanced coverage arm. Enhanced coverage reduced ocular Chlamydia prevalence in children more quickly over time compared with standard ( P = 0.04). There was no difference between arms at 36 months in children (2.4% lower with enhanced coverage, 95% CI 7.7-12.5%; P = 0.60). No infection was detected in adults at 36 months. Increasing antibiotic coverage among children from 80% to 90% may yield only short term improvements for trachoma control programs. Targeting treatment to children alone may be sufficient for trachoma control in this setting.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ekici, Kemal, E-mail: drkemal06@hotmail.com; Pepele, Eda K.; Yaprak, Bahaddin
2016-01-01
Various radiotherapy planning methods for T1N0 laryngeal cancer have been proposed to decrease normal tissue toxicity. We compare helical tomotherapy (HT), linac-based intensity-modulated radiation therapy (IMRT), volumetric-modulated arc therapy (VMAT), and 3-D conformal radiotherapy (3D-CRT) techniques for T1N0 laryngeal cancer. Overall, 10 patients with T1N0 laryngeal cancer were selected and evaluated. Furthermore, 10 radiotherapy treatment plans have been created for all 10 patients, including HT, IMRT, VMAT, and 3D-CRT. IMRT, VMAT, and HT plans vs 3D-CRT plans consistently provided superior planning target volume (PTV) coverage. Similar target coverage was observed between the 3 IMRT modalities. Compared with 3D-CRT, IMRT, HT,more » and VMAT significantly reduced the mean dose to the carotid arteries. VMAT resulted in the lowest mean dose to the submandibular and thyroid glands. Compared with 3D-CRT, IMRT, HT, and VMAT significantly increased the maximum dose to the spinal cord It was observed that the 3 IMRT modalities studied showed superior target coverage with less variation between each plan in comparison with 3D-CRT. The 3D-CRT plans performed better at the D{sub max} of the spinal cord. Clinical investigation is warranted to determine if these treatment approaches would translate into a reduction in radiation therapy–induced toxicities.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bosarge, Christina L., E-mail: cbosarge@umail.iu.edu; Ewing, Marvene M.; DesRosiers, Colleen M.
To demonstrate the dosimetric advantages and disadvantages of standard anteroposterior-posteroanterior (S-AP/PA{sub AAA}), inverse-planned AP/PA (IP-AP/PA) and volumetry-modulated arc (VMAT) radiotherapies in the treatment of children undergoing whole-lung irradiation. Each technique was evaluated by means of target coverage and normal tissue sparing, including data regarding low doses. A historical approach with and without tissue heterogeneity corrections is also demonstrated. Computed tomography (CT) scans of 10 children scanned from the neck to the reproductive organs were used. For each scan, 6 plans were created: (1) S-AP/PA{sub AAA} using the anisotropic analytical algorithm (AAA), (2) IP-AP/PA, (3) VMAT, (4) S-AP/PA{sub NONE} without heterogeneitymore » corrections, (5) S-AP/PA{sub PB} using the Pencil-Beam algorithm and enforcing monitor units from technique 4, and (6) S-AP/PA{sub AAA[FM]} using AAA and forcing fixed monitor units. The first 3 plans compare modern methods and were evaluated based on target coverage and normal tissue sparing. Body maximum and lower body doses (50% and 30%) were also analyzed. Plans 4 to 6 provide a historic view on the progression of heterogeneity algorithms and elucidate what was actually delivered in the past. Averages of each comparison parameter were calculated for all techniques. The S-AP/PA{sub AAA} technique resulted in superior target coverage but had the highest maximum dose to every normal tissue structure. The IP-AP/PA technique provided the lowest dose to the esophagus, stomach, and lower body doses. VMAT excelled at body maximum dose and maximum doses to the heart, spine, and spleen, but resulted in the highest dose in the 30% body range. It was, however, superior to the S-AP/PA{sub AAA} approach in the 50% range. Each approach has strengths and weaknesses thus associated. Techniques may be selected on a case-by-case basis and by physician preference of target coverage vs normal tissue sparing.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dellamonica, D.; Luo, G.; Ding, G.
Purpose: Setup errors on the order of millimeters may cause under-dosing of targets and significant changes in dose to critical structures especially when planning with tight margins in stereotactic radiosurgery. This study evaluates the effects of these types of patient positioning uncertainties on planning target volume (PTV) coverage and cochlear dose for stereotactic treatments of acoustic neuromas. Methods: Twelve acoustic neuroma patient treatment plans were retrospectively evaluated in Brainlab iPlan RT Dose 4.1.3. All treatment beams were shaped by HDMLC from a Varian TX machine. Seven patients had planning margins of 2mm, five had 1–1.5mm. Six treatment plans were createdmore » for each patient simulating a 1mm setup error in six possible directions: anterior-posterior, lateral, and superiorinferior. The arcs and HDMLC shapes were kept the same for each plan. Change in PTV coverage and mean dose to the cochlea was evaluated for each plan. Results: The average change in PTV coverage for the 72 simulated plans was −1.7% (range: −5 to +1.1%). The largest average change in coverage was observed for shifts in the patient's superior direction (−2.9%). The change in mean cochlear dose was highly dependent upon the direction of the shift. Shifts in the anterior and superior direction resulted in an average increase in dose of 13.5 and 3.8%, respectively, while shifts in the posterior and inferior direction resulted in an average decrease in dose of 17.9 and 10.2%. The average change in dose to the cochlea was 13.9% (range: 1.4 to 48.6%). No difference was observed based on the size of the planning margin. Conclusion: This study indicates that if the positioning uncertainty is kept within 1mm the setup errors may not result in significant under-dosing of the acoustic neuroma target volumes. However, the change in mean cochlear dose is highly dependent upon the direction of the shift.« less
Dosimetric comparison of photon and proton treatment techniques for chondrosarcoma of thoracic spine
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yadav, Poonam, E-mail: yadav@humonc.wisc.edu; Department of Medical Physics, University of Wisconsin, Madison, WI; University of Wisconsin Riverview Cancer Center, Wisconsin Rapids, WI
2013-10-01
Chondrosarcomas are relatively radiotherapy resistant, and also delivering high radiation doses is not feasible owing to anatomic constraints. In this study, the feasibility of helical tomotherapy for treatment of chondrosarcoma of thoracic spine is explored and compared with other available photon and proton radiotherapy techniques in the clinical setting. A patient was treated for high-grade chondrosarcoma of the thoracic spine using tomotherapy. Retrospectively, the tomotherapy plan was compared with intensity-modulated radiation therapy, dynamic arc photon therapy, and proton therapy. Two primary comparisons were made: (1) comparison of normal tissue sparing with comparable target volume coverage (plan-1), and (2) comparison ofmore » target volume coverage with a constrained maximum dose to the cord center (plan-2). With constrained target volume coverage, proton plans were found to yield lower mean doses for all organs at risk (spinal cord, esophagus, heart, and both lungs). Tomotherapy planning resulted in the lowest mean dose to all organs at risk amongst photon-based methods. For cord dose constrained plans, the static-field intensity-modulated radiation therapy and dynamic arc plans resulted target underdosing in 20% and 12% of planning target volume2 volumes, respectively, whereas both proton and tomotherapy plans provided clinically acceptable target volume coverage with no portion of planning target volume2 receiving less than 90% of the prescribed dose. Tomotherapy plans are comparable to proton plans and produce superior results compared with other photon modalities. This feasibility study suggests that tomotherapy is an attractive alternative to proton radiotherapy for delivering high doses to lesions in the thoracic spine.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Frame, C; Ding, G
Purpose: To quantify patient setups errors based on bony anatomy registration rather than 3D tumor alignment for SBRT lung treatments. Method: A retrospective study was performed for patients treated with lung SBRT and imaged with kV cone beam computed tomography (kV-CBCT) image-guidance. Daily CBCT images were registered to treatment planning CTs based on bony anatomy alignment and then inter-fraction tumor movement was evaluated by comparing shift in the tumor center in the medial-lateral, anterior-posterior, and superior-inferior directions. The PTV V100% was evaluated for each patient based on the average daily tumor displacement to assess the impact of the positioning errormore » on the target coverage when the registrations were based on bony anatomy. Of the 35 patients studied, 15 were free-breathing treatments, 10 used abdominal compression with a stereotactic body frame, and the remaining 10 were performed with BodyFIX vacuum bags. Results: For free-breathing treatments, the range of tumor displacement error is between 1–6 mm in the medial-lateral, 1–13 mm in the anterior-posterior, and 1–7 mm in the superior-inferior directions. These positioning errors lead to 6–22% underdose coverage for PTV - V100% . Patients treated with abdominal compression immobilization showed positional errors of 0–4mm mediallaterally, 0–3mm anterior-posteriorly, and 0–2 mm inferior-superiorly with PTV - V100% underdose ranging between 6–17%. For patients immobilized with the vacuum bags, the positional errors were found to be 0–1 mm medial-laterally, 0–1mm anterior-posteriorly, and 0–2 mm inferior-superiorly with PTV - V100% under dose ranging between 5–6% only. Conclusion: It is necessary to align the tumor target by using 3D image guidance to ensure adequate tumor coverage before performing SBRT lung treatments. The BodyFIX vacuum bag immobilization method has the least positioning errors among the three methods studied when bony anatomy is used for registration.« less
SU-F-T-392: Superior Brainstem and Cochlea Sparing with VMAT for Glioblastoma Multiforme
DOE Office of Scientific and Technical Information (OSTI.GOV)
Briere, TM; McAleer, MF; Levy, LB
Purpose: Volumetric arc therapy (VMAT) can provide similar target coverage and normal tissue sparing as IMRT but with shorter treatment times. At our institution VMAT was adopted for the treatment glioblastoma multiforme (GBM) after a small number of test plans demonstrated its non-inferiority. In this study, we compare actual clinical treatment plans for a larger cohort of patients treated with either VMAT or IMRT. Methods: 90 GBM patients were included in this study, 45 treated with IMRT and 45 with VMAT. All planning target volumes (PTVs) were prescribed a dose of 50 Gy, with a simultaneous integrated boost to 60more » Gy. Most IMRT plans used 5 non-coplanar beams, while most VMAT plans used 2 coplanar beams. Statistical analysis was performed using Fisher’s exact test or the Wilcoxon-Mann-Whitney rank sum test. Included in the analysis were patient and treatment characteristics as well as the doses to the target volumes and organs at risk. Results: Treatment times for the VMAT plans were reduced by 5 minutes compared with IMRT. The PTV coverage was similar, with at least 95% covered for all plans, while the median boost PTV dose differed by 0.1 Gy between the IMRT and VMAT cohorts. The doses to the brain, optic chiasm, optic nerves and eyes were not significantly different. The mean dose to the brainstem, however, was 9.4 Gy less with VMAT (p<0.001). The dose to the ipsilateral and contralateral cochleae were respectively 19.7 and 9.5 Gy less (p<0.001). Conclusion: Comparison of clinical treatment plans for separate IMRT and VMAT cohorts demonstrates that VMAT can save substantial treatment time while providing similar target coverage and superior sparing of the brainstem and cochleae. To our knowledge this is the first study to demonstrate this benefit of VMAT in the management of GBM.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pham, Daniel, E-mail: Daniel.Pham@petermac.org; Kron, Tomas; Foroudi, Farshad
2013-10-01
Stereotactic ablative body radiotherapy (SABR) for primary renal cell carcinoma (RCC) targets requires motion management strategies to verify dose delivery. This case study highlights the effect of a change in patient breathing amplitude on the dosimetry to organs at risk and target structures. A 73-year-old male patient was planned for receiving 26 Gy of radiation in 1 fraction of SABR for a left primary RCC. The patient was simulated with four-dimensional computed tomography (4DCT) and the tumor internal target volume (ITV) was delineated using the 4DCT maximum intensity projection. However, the initially planned treatment was abandoned at the radiation oncologist'smore » discretion after pretreatment cone-beam CT (CBCT) motion verification identified a greater than 50% reduction in superior to inferior diaphragm motion as compared with the planning 4DCT. This patient was resimulated with respiratory coaching instructions. To assess the effect of the change in breathing on the dosimetry to the target, each plan was recalculated on the data set representing the change in breathing condition. A change from smaller to larger breathing showed a 46% loss in planning target volume (PTV) coverage, whereas a change from larger breathing to smaller breathing resulted in an 8% decrease in PTV coverage. ITV coverage was similarly reduced by 8% in both scenarios. This case study highlights the importance of tools to verify breathing motion prior to treatment delivery. 4D image guided radiation therapy verification strategies should focus on not only verifying ITV margin coverage but also the effect on the surrounding organs at risk.« less
Upgrades to the NOAA/NESDIS automated Cloud-Motion Vector system
NASA Technical Reports Server (NTRS)
Nieman, Steve; Menzel, W. Paul; Hayden, Christopher M.; Wanzong, Steve; Velden, Christopher S.
1993-01-01
The latest version of the automated cloud motion vector software has yielded significant improvements in the quality of the GOES cloud-drift winds produced operationally by NESDIS. Cloud motion vectors resulting from the automated system are now equal or superior in quality to those which had the benefit of manual quality control a few years ago. The single most important factor in this improvement has been the upgraded auto-editor. Improved tracer selection procedures eliminate targets in difficult regions and allow a higher target density and therefore enhanced coverage in areas of interest. The incorporation of the H2O-intercept height assignment method allows an adequate representation of the heights of semi-transparent clouds in the absence of a CO2-absorption channel. Finally, GOES-8 water-vapor motion winds resulting from the automated system are superior to any done previously by NESDIS and should now be considered as an operational product.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Feng, Z; Yu, G; Qin, S
Purpose: This study investigated that how the quality of adapted plan was affected by inter-fractional anatomy deformation by using one-step and two-step optimization for on line adaptive radiotherapy (ART) procedure. Methods: 10 lung carcinoma patients were chosen randomly to produce IMRT plan by one-step and two-step algorithms respectively, and the prescribed dose was set as 60 Gy on the planning target volume (PTV) for all patients. To simulate inter-fractional target deformation, four specific cases were created by systematic anatomy variation; including target superior shift 0.5 cm, 0.3cm contraction, 0.3 cm expansion and 45-degree rotation. Based on these four anatomy deformation,more » adapted plan, regenerated plan and non-adapted plan were created to evaluate quality of adaptation. Adapted plans were generated automatically by using one-step and two-step algorithms respectively to optimize original plans, and regenerated plans were manually created by experience physicists. Non-adapted plans were produced by recalculating the dose distribution based on corresponding original plans. The deviations among these three plans were statistically analyzed by paired T-test. Results: In PTV superior shift case, adapted plans had significantly better PTV coverage by using two-step algorithm compared with one-step one, and meanwhile there was a significant difference of V95 by comparison with adapted and non-adapted plans (p=0.0025). In target contraction deformation, with almost same PTV coverage, the total lung received lower dose using one-step algorithm than two-step algorithm (p=0.0143,0.0126 for V20, Dmean respectively). In other two deformation cases, there were no significant differences observed by both two optimized algorithms. Conclusion: In geometry deformation such as target contraction, with comparable PTV coverage, one-step algorithm gave better OAR sparing than two-step algorithm. Reversely, the adaptation by using two-step algorithm had higher efficiency and accuracy as target occurred position displacement. We want to thank Dr. Lei Xing and Dr. Yong Yang in the Stanford University School of Medicine for this work. This work was jointly supported by NSFC (61471226), Natural Science Foundation for Distinguished Young Scholars of Shandong Province (JQ201516), and China Postdoctoral Science Foundation (2015T80739, 2014M551949).« less
The rationale for intensity-modulated proton therapy in geometrically challenging cases
NASA Astrophysics Data System (ADS)
Safai, S.; Trofimov, A.; Adams, J. A.; Engelsman, M.; Bortfeld, T.
2013-09-01
Intensity-modulated proton therapy (IMPT) delivered with beam scanning is currently available at a limited number of proton centers. However, a simplified form of IMPT, the technique of field ‘patching’, has long been a standard practice in proton therapy centers. In field patching, different parts of the target volume are treated from different directions, i.e., a part of the tumor gets either full dose from a radiation field, or almost no dose. Thus, patching represents a form of binary intensity modulation. This study explores the limitations of the standard binary field patching technique, and evaluates possible dosimetric advantages of continuous dose modulations in IMPT. Specifics of the beam delivery technology, i.e., pencil beam scanning versus passive scattering and modulation, are not investigated. We have identified two geometries of target volumes and organs at risk (OAR) in which the use of field patching is severely challenged. We focused our investigations on two patient cases that exhibit these geometries: a paraspinal tumor case and a skull-base case. For those cases we performed treatment planning comparisons of three-dimensional conformal proton therapy (3DCPT) with field patching versus IMPT, using commercial and in-house software, respectively. We also analyzed the robustness of the resulting plans with respect to systematic setup errors of ±1 mm and range errors of ±2.5 mm. IMPT is able to better spare OAR while providing superior dose coverage for the challenging cases identified above. Both 3DCPT and IMPT are sensitive to setup errors and range uncertainties, with IMPT showing the largest effect. Nevertheless, when delivery uncertainties are taken into account IMPT plans remain superior regarding target coverage and OAR sparing. On the other hand, some clinical goals, such as the maximum dose to OAR, are more likely to be unmet with IMPT under large range errors. IMPT can potentially improve target coverage and OAR sparing in challenging cases, even when compared with the relatively complicated and time consuming field patching technique. While IMPT plans tend to be more sensitive to delivery uncertainties, their dosimetric advantage generally holds. Robust treatment planning techniques may further reduce the sensitivity of IMPT plans.
Efficient Deployment of Key Nodes for Optimal Coverage of Industrial Mobile Wireless Networks
Li, Xiaomin; Li, Di; Dong, Zhijie; Hu, Yage; Liu, Chengliang
2018-01-01
In recent years, industrial wireless networks (IWNs) have been transformed by the introduction of mobile nodes, and they now offer increased extensibility, mobility, and flexibility. Nevertheless, mobile nodes pose efficiency and reliability challenges. Efficient node deployment and management of channel interference directly affect network system performance, particularly for key node placement in clustered wireless networks. This study analyzes this system model, considering both industrial properties of wireless networks and their mobility. Then, static and mobile node coverage problems are unified and simplified to target coverage problems. We propose a novel strategy for the deployment of clustered heads in grouped industrial mobile wireless networks (IMWNs) based on the improved maximal clique model and the iterative computation of new candidate cluster head positions. The maximal cliques are obtained via a double-layer Tabu search. Each cluster head updates its new position via an improved virtual force while moving with full coverage to find the minimal inter-cluster interference. Finally, we develop a simulation environment. The simulation results, based on a performance comparison, show the efficacy of the proposed strategies and their superiority over current approaches. PMID:29439439
DOE Office of Scientific and Technical Information (OSTI.GOV)
Parker, William; Filion, Edith; Roberge, David
2007-09-01
Purpose: To report the results of an analysis of dose received to tissues and organs outside the target volume, in the setting of spinal axis irradiation for the treatment of medulloblastoma, using three treatment techniques. Methods and Materials: Treatment plans (total dose, 23.4 Gy) for a standard two-dimensional (2D) technique, a three-dimensional (3D) technique using a 3D imaging-based target volume, and an intensity-modulated radiotherapy (IMRT) technique, were compared for 3 patients in terms of dose-volume statistics for target coverage, as well as organ at risk (OAR) and overall tissue sparing. Results: Planning target volume coverage and dose homogeneity was superiormore » for the IMRT plans for V{sub 95%} (IMRT, 100%; 3D, 96%; 2D, 98%) and V{sub 107%} (IMRT, 3%; 3D, 38%; 2D, 37%). In terms of OAR sparing, the IMRT plan was better for all organs and whole-body contour when comparing V{sub 10Gy}, V{sub 15Gy}, and V{sub 20Gy}. The 3D plan was superior for V{sub 5Gy} and below. For the heart and liver in particular, the IMRT plans provided considerable sparing in terms of V{sub 10Gy} and above. In terms of the integral dose, the IMRT plans were superior for liver (IMRT, 21.9 J; 3D, 28.6 J; 2D, 38.6 J) and heart (IMRT, 9 J; 3D, 14.1J; 2D, 19.4 J), the 3D plan for the body contour (IMRT, 349 J; 3D, 337 J; 2D, 555 J). Conclusions: Intensity-modulated radiotherapy is a valid treatment option for spinal axis irradiation. We have shown that IMRT results in sparing of organs at risk without a significant increase in integral dose.« less
Inverse 4D conformal planning for lung SBRT using particle swarm optimization
NASA Astrophysics Data System (ADS)
Modiri, A.; Gu, X.; Hagan, A.; Bland, R.; Iyengar, P.; Timmerman, R.; Sawant, A.
2016-08-01
A critical aspect of highly potent regimens such as lung stereotactic body radiation therapy (SBRT) is to avoid collateral toxicity while achieving planning target volume (PTV) coverage. In this work, we describe four dimensional conformal radiotherapy using a highly parallelizable swarm intelligence-based stochastic optimization technique. Conventional lung CRT-SBRT uses a 4DCT to create an internal target volume and then, using forward-planning, generates a 3D conformal plan. In contrast, we investigate an inverse-planning strategy that uses 4DCT data to create a 4D conformal plan, which is optimized across the three spatial dimensions (3D) as well as time, as represented by the respiratory phase. The key idea is to use respiratory motion as an additional degree of freedom. We iteratively adjust fluence weights for all beam apertures across all respiratory phases considering OAR sparing, PTV coverage and delivery efficiency. To demonstrate proof-of-concept, five non-small-cell lung cancer SBRT patients were retrospectively studied. The 4D optimized plans achieved PTV coverage comparable to the corresponding clinically delivered plans while showing significantly superior OAR sparing ranging from 26% to 83% for D max heart, 10%-41% for D max esophagus, 31%-68% for D max spinal cord and 7%-32% for V 13 lung.
Inverse 4D conformal planning for lung SBRT using particle swarm optimization
Modiri, A; Gu, X; Hagan, A; Bland, R; Iyengar, P; Timmerman, R; Sawant, A
2016-01-01
A critical aspect of highly potent regimens such as lung stereotactic body radiation therapy (SBRT) is to avoid collateral toxicity while achieving planning target volume (PTV) coverage. In this work, we describe four dimensional conformal radiotherapy (4D CRT) using a highly parallelizable swarm intelligence-based stochastic optimization technique. Conventional lung CRT-SBRT uses a 4DCT to create an internal target volume (ITV) and then, using forward-planning, generates a 3D conformal plan. In contrast, we investigate an inverse-planning strategy that uses 4DCT data to create a 4D conformal plan, which is optimized across the three spatial dimensions (3D) as well as time, as represented by the respiratory phase. The key idea is to use respiratory motion as an additional degree of freedom. We iteratively adjust fluence weights for all beam apertures across all respiratory phases considering OAR sparing, PTV coverage and delivery efficiency. To demonstrate proof-of-concept, five non-small-cell lung cancer SBRT patients were retrospectively studied. The 4D optimized plans achieved PTV coverage comparable to the corresponding clinically delivered plans while showing significantly superior OAR sparing ranging from 26% to 83% for Dmax heart, 10% to 41% for Dmax esophagus, 31% to 68% for Dmax spinal cord and 7% to 32% for V13 lung. PMID:27476472
DOE Office of Scientific and Technical Information (OSTI.GOV)
Syh, J; Syh, J; Patel, B
2014-06-15
Purpose: The multichannel cylindrical vaginal applicator is a variation of traditional single channel cylindrical vaginal applicator. The multichannel applicator has additional peripheral channels that provide more flexibility in the planning process. The dosimetric advantage is to reduce dose to adjacent organ at risk (OAR) such as bladder and rectum while maintaining target coverage with the dose optimization from additional channels. Methods: Vaginal HDR brachytherapy plans are all CT based. CT images were acquired in 2 mm thickness to keep integrity of cylinder contouring. The CTV of 5mm Rind with prescribed treatment length was reconstructed from 5mm expansion of inserted cylinder.more » The goal was 95% of CTV covered by 95% of prescribed dose in both single channel planning (SCP)and multichannel planning (MCP) before proceeding any further optimization for dose reduction to critical structures with emphasis on D2cc and V2Gy . Results: This study demonstrated noticeable dose reduction to OAR was apparent in multichannel plans. The D2cc of the rectum and bladder were showing the reduced dose for multichannel versus single channel. The V2Gy of the rectum was 93.72% and 83.79% (p=0.007) for single channel and multichannel respectively (Figure 1 and Table 1). To assure adequate coverage to target while reducing the dose to the OAR without any compromise is the main goal in using multichannel vaginal applicator in HDR brachytherapy. Conclusion: Multichannel plans were optimized using anatomical based inverse optimization algorithm of inverse planning simulation annealing. The optimization solution of the algorithm was to improve the clinical target volume dose coverage while reducing the dose to critical organs such as bladder, rectum and bowels. The comparison between SCP and MCP demonstrated MCP is superior to SCP where the dwell positions were based on geometric array only. It concluded that MCP is preferable and is able to provide certain features superior to SCP.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hernandez, Victor, E-mail: vhernandezmasgrau@gmail.com; Arenas, Meritxell; Müller, Katrin
2013-01-01
To assess the advantages of an optimized posterior axillary (AX) boost technique for the irradiation of supraclavicular (SC) and AX lymph nodes. Five techniques for the treatment of SC and levels I, II, and III AX lymph nodes were evaluated for 10 patients selected at random: a direct anterior field (AP); an anterior to posterior parallel pair (AP-PA); an anterior field with a posterior axillary boost (PAB); an anterior field with an anterior axillary boost (AAB); and an optimized PAB technique (OptPAB). The target coverage, hot spots, irradiated volume, and dose to organs at risk were evaluated and a statisticalmore » analysis comparison was performed. The AP technique delivered insufficient dose to the deeper AX nodes. The AP-PA technique produced larger irradiated volumes and higher mean lung doses than the other techniques. The PAB and AAB techniques originated excessive hot spots in most of the cases. The OptPAB technique produced moderate hot spots while maintaining a similar planning target volume (PTV) coverage, irradiated volume, and dose to organs at risk. This optimized technique combines the advantages of the PAB and AP-PA techniques, with moderate hot spots, sufficient target coverage, and adequate sparing of normal tissues. The presented technique is simple, fast, and easy to implement in routine clinical practice and is superior to the techniques historically used for the treatment of SC and AX lymph nodes.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lin, T; Wang, L; Galloway, T
Purpose: Head and Neck cancer treatment with IMRT/VMAT has two choices: split-filed IMRT(SFI), in which the LAN is treated with a separate anterior field and the extended whole-field IMRT(WFI) in which LAN is included with the IMRT/VMAT field. This study shows that under the same dose limit criteria, choosing the technique becomes a critical issue if daily localization and immobilization altered the dose distribution. Methods: Nine common head-and-neck cancer cases were chosen to illustrate how the daily localization and immobilization uncertainties affect to choose between SFI and WFI. Both SFI and WFI at upper target coverage were generated with VMAT.more » For each case, the same planning criteria were applied to the target and critical structures; therefore, similar target coverage and dose falloff can be observed in both techniques. Thirty days of kV cone beam CT(CBCT) images on each case were also delineated with contralateral and ipsilateral target as well as larynx as critical structure. About 300 CBCT images with daily delivered doses were analyzed and compared in a form of dose-volume histograms. Results: While both plans for SFI and WFI with VMAT planning utilized and meet the criteria of D95>prescription dose and for not-involved larynx with mean dose <35Gy and V55<10%, the daily localization and immobilization has a great contribution to the resulted dose delivery. With WFI, the better daily contralateral and ipsilateral neck target coverage can reflect a simpler or shorter localization; however, a much superior avoidance (WFI: mean dose a 42.5Gy; SFI: mean dose a 18.9Gy) of the non-involved larynx from the SFI is preferred. Conclusion: Dosimetrically, SFI and WFI are equally well for head and Neck cancer treatment with VMAT technique; however, if considering the contribution of daily localization(CBCT) method uncertainties, SFI is better with sparing non-involved larynx and WFI has better target coverage.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sherertz, T; Ellis, R; Colussi, V
2014-06-15
Purpose: To evaluate volumetric coverage of a Mick Radionuclear titanium Split-Ring applicator (SRA) with/without interstitial needle compared to an intracavitary Vienna applicator (VA), interstitial-intracavitary VA, and intracavitary ring and tandem applicator (RTA). Methods: A 57 year-old female with FIGO stage IIB cervical carcinoma was treated following chemoradiotherapy (45Gy pelvic and 5.4Gy parametrial boost) with highdose- rate (HDR) brachytherapy to 30Gy in 5 fractions using a SRA. A single interstitial needle was placed using the Ellis Interstitial Cap for the final three fractions to increase coverage of left-sided gross residual disease identified on 3T-MRI. High-risk (HR) clinical target volume (CTV) andmore » intermediate-risk (IR) CTV were defined using axial T2-weighted 2D and 3D MRI sequences (Philips PET/MRI unit). Organs-at-risks (OARs) were delineated on CT. Oncentra planning system was used for treatment optimization satisfying GEC-ESTRO guidelines for target coverage and OAR constraints. Retrospectively, treatment plans (additional 20 plans) were simulated using intracavitary SRA (without needle), intracavitary VA (without needle), interstitial-intracavitary VA, and intracavitary RTA with this same patient case. Plans were optimized for each fraction to maintain coverage to HR-CTV. Results: Interstitial-intracavitary SRA achieved the following combined coverage for external radiation and brachytherapy (EQD2): D90 HR-CTV =94.6Gy; Bladder-2cc =88.9Gy; Rectum-2cc =65.1Gy; Sigmoid-2cc =48.9Gy; Left vaginal wall (VW) =103Gy, Right VW =99.2Gy. Interstitial-intracavitary VA was able to achieve identical D90 HR-CTV =94.6Gy, yet Bladder-2cc =91.9Gy (exceeding GEC-ESTRO recommendations of 2cc<90Gy) and Left VW =120.8Gy and Right VW =115.5Gy. Neither the SRA nor VA without interstitial needle could cover HR-CTV adequately without exceeding dose to Bladder-2cc. Conventional RTA was unable to achieve target coverage for the HR-CTV >80Gy without severely overdosing OARs. Conclusion: The Ellis Interstitial Cap for the SRA offered superior dosimetric coverage as compared to the interstitialintracavitary VA. This represents the first reported use for this devise, and further investigation is warranted.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sivakumar, R; Janardhan, N; Bhavani, P
Purpose: To compare the plan quality and performance of Simultaneous Integrated Boost (SIB) Treatment plan between Seven field (7F) and Nine field(9F) Intensity Modulated Radiotherapies and Single Arc (SA) and Dual Arc (DA) Volumetric Modulated Arc Therapy( VMAT). Methods: Retrospective planning study of 16 patients treated in Elekta Synergy Platform (mlci2) by 9F-IMRT were replanned with 7F-IMRT, Single Arc VMAT and Dual Arc VMAT using CMS, Monaco Treatment Planning System (TPS) with Monte Carlo simulation. Target delineation done as per Radiation Therapy Oncology Protocols (RTOG 0225&0615). Dose Prescribed as 70Gy to Planning Target Volumes (PTV70) and 61Gy to PTV61 inmore » 33 fraction as a SIB technique. Conformity Index(CI), Homogeneity Index(HI) were used as analysis parameter for Target Volumes as well as Mean dose and Max dose for Organ at Risk(OAR,s).Treatment Delivery Time(min), Monitor unit per fraction (MU/fraction), Patient specific quality assurance were also analysed. Results: A Poor dose coverage and Conformity index (CI) was observed in PTV70 by 7F-IMRT among other techniques. SA-VMAT achieved poor dose coverage in PTV61. No statistical significance difference observed in OAR,s except Spinal cord (P= 0.03) and Right optic nerve (P=0.03). DA-VMAT achieved superior target coverage, higher CI (P =0.02) and Better HI (P=0.03) for PTV70 other techniques (7F-IMRT/9F-IMRT/SA-VMAT). A better dose spare for Parotid glands and spinal cord were seen in DA-VMAT. The average treatment delivery time were 5.82mins, 6.72mins, 3.24mins, 4.3mins for 7F-IMRT, 9F-IMRT, SA-VMAT and DA-VMAT respectively. Significance difference Observed in MU/fr (P <0.001) and Patient quality assurance pass rate were >95% (Gamma analysis (Γ3mm, 3%). Conclusion: DA-VAMT showed better target dose coverage and achieved better or equal performance in sparing OARs among other techniques. SA-VMAT offered least Treatment Time than other techniques but achieved poor target coverage. DA-VMAT offered shorter delivery time than 7F-IMRT and 9F-IMRT without compromising the plan quality.« less
ERIC Educational Resources Information Center
David, Matthew
2016-01-01
UK media coverage of global university league tables shows systematic bias towards the Russell Group, although also highlighting tensions within its membership. Coverage positions UK "elite" institutions between US superiority and Asian ascent. Coverage claims that league table results warrant UK university funding reform. However,…
4D Optimization of Scanned Ion Beam Tracking Therapy for Moving Tumors
Eley, John Gordon; Newhauser, Wayne David; Lüchtenborg, Robert; Graeff, Christian; Bert, Christoph
2014-01-01
Motion mitigation strategies are needed to fully realize the theoretical advantages of scanned ion beam therapy for patients with moving tumors. The purpose of this study was to determine whether a new four-dimensional (4D) optimization approach for scanned-ion-beam tracking could reduce dose to avoidance volumes near a moving target while maintaining target dose coverage, compared to an existing 3D-optimized beam tracking approach. We tested these approaches computationally using a simple 4D geometrical phantom and a complex anatomic phantom, that is, a 4D computed tomogram of the thorax of a lung cancer patient. We also validated our findings using measurements of carbon-ion beams with a motorized film phantom. Relative to 3D-optimized beam tracking, 4D-optimized beam tracking reduced the maximum predicted dose to avoidance volumes by 53% in the simple phantom and by 13% in the thorax phantom. 4D-optimized beam tracking provided similar target dose homogeneity in the simple phantom (standard deviation of target dose was 0.4% versus 0.3%) and dramatically superior homogeneity in the thorax phantom (D5-D95 was 1.9% versus 38.7%). Measurements demonstrated that delivery of 4D-optimized beam tracking was technically feasible and confirmed a 42% decrease in maximum film exposure in the avoidance region compared with 3D-optimized beam tracking. In conclusion, we found that 4D-optimized beam tracking can reduce the maximum dose to avoidance volumes near a moving target while maintaining target dose coverage, compared with 3D-optimized beam tracking. PMID:24889215
4D optimization of scanned ion beam tracking therapy for moving tumors
NASA Astrophysics Data System (ADS)
Eley, John Gordon; Newhauser, Wayne David; Lüchtenborg, Robert; Graeff, Christian; Bert, Christoph
2014-07-01
Motion mitigation strategies are needed to fully realize the theoretical advantages of scanned ion beam therapy for patients with moving tumors. The purpose of this study was to determine whether a new four-dimensional (4D) optimization approach for scanned-ion-beam tracking could reduce dose to avoidance volumes near a moving target while maintaining target dose coverage, compared to an existing 3D-optimized beam tracking approach. We tested these approaches computationally using a simple 4D geometrical phantom and a complex anatomic phantom, that is, a 4D computed tomogram of the thorax of a lung cancer patient. We also validated our findings using measurements of carbon-ion beams with a motorized film phantom. Relative to 3D-optimized beam tracking, 4D-optimized beam tracking reduced the maximum predicted dose to avoidance volumes by 53% in the simple phantom and by 13% in the thorax phantom. 4D-optimized beam tracking provided similar target dose homogeneity in the simple phantom (standard deviation of target dose was 0.4% versus 0.3%) and dramatically superior homogeneity in the thorax phantom (D5-D95 was 1.9% versus 38.7%). Measurements demonstrated that delivery of 4D-optimized beam tracking was technically feasible and confirmed a 42% decrease in maximum film exposure in the avoidance region compared with 3D-optimized beam tracking. In conclusion, we found that 4D-optimized beam tracking can reduce the maximum dose to avoidance volumes near a moving target while maintaining target dose coverage, compared with 3D-optimized beam tracking.
Generalizable Class Solutions for Treatment Planning of Spinal Stereotactic Body Radiation Therapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Weksberg, David C.; Palmer, Matthew B.; Vu, Khoi N.
2012-11-01
Purpose: Spinal stereotactic body radiation therapy (SBRT) continues to emerge as an effective therapeutic approach to spinal metastases; however, treatment planning and delivery remain resource intensive at many centers, which may hamper efficient implementation in clinical practice. We sought to develop a generalizable class solution approach for spinal SBRT treatment planning that would allow confidence that a given plan provides optimal target coverage, reduce integral dose, and maximize planning efficiency. Methods and Materials: We examined 91 patients treated with spinal SBRT at our institution. Treatment plans were categorized by lesion location, clinical target volume (CTV) configuration, and dose fractionation scheme,more » and then analyzed to determine the technically achievable dose gradient. A radial cord expansion was subtracted from the CTV to yield a planning CTV (pCTV) construct for plan evaluation. We reviewed the treatment plans with respect to target coverage, dose gradient, integral dose, conformality, and maximum cord dose to select the best plans and develop a set of class solutions. Results: The class solution technique generated plans that maintained target coverage and improved conformality (1.2-fold increase in the 95% van't Riet Conformation Number describing the conformality of a reference dose to the target) while reducing normal tissue integral dose (1.3-fold decrease in the volume receiving 4 Gy (V{sub 4Gy}) and machine output (19% monitor unit (MU) reduction). In trials of planning efficiency, the class solution technique reduced treatment planning time by 30% to 60% and MUs required by {approx}20%: an effect independent of prior planning experience. Conclusions: We have developed a set of class solutions for spinal SBRT that incorporate a pCTV metric for plan evaluation while yielding dosimetrically superior treatment plans with increased planning efficiency. Our technique thus allows for efficient, reproducible, and high-quality spinal SBRT treatment planning.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yim, Jackie; Suttie, Clare; Bromley, Regina
We report on a retrospective dosimetric study, comparing 3D conformal radiotherapy (3DCRT) and hybrid intensity modulated radiotherapy (hIMRT). We evaluated plans based on their planning target volume coverage, dose homogeneity, dose to organs at risk (OARs) and exposure of normal tissue to radiation. The Homogeneity Index (HI) was used to assess the dose homogeneity in the target region, and we describe a new index, the normal tissue index (NTI), to assess the dose in the normal tissue inside the tangent treatment portal. Plans were generated for 25 early-stage breast cancer patients, using a hIMRT technique. These were compared with themore » 3DCRT plans of the treatment previously received by the patients. Plan quality was evaluated using the HI, NTI and dose to OARs. The hIMRT technique was significantly more homogenous than the 3DCRT technique, while maintaining target coverage. The hIMRT technique was also superior at minimising the amount of tissue receiving D{sub 105%} and above (P < 0.0001). The ipsilateral lung and contralateral breast maximum were significantly lower in the hIMRT plans (P < 0.05 and P < 0.005), but the 3DCRT technique achieved a lower mean heart dose in left-sided breast cancer patients (P < 0.05). Hybrid intensity modulated radiotherapy plans achieved improved dose homogeneity compared to the 3DCRT plans and superior outcome with regard to dose to normal tissues. We propose that the addition of both HI and NTI in evaluating the quality of intensity modulated radiotherapy (IMRT) breast plans provides clinically relevant comparators which more accurately reflect the new paradigm of treatment goals and outcomes in the era of breast IMRT.« less
NASA Astrophysics Data System (ADS)
Lee, Suk; Cao, Yuan Jie; Chang, Kyung Hwan; Shim, Jang Bo; Kim, Kwang Hyeon; Lee, Nam Kwon; Park, Young Je; Kim, Chul Yong; Cho, Sam Ju; Lee, Sang Hoon; Min, Chul Kee; Kim, Woo Chul; Cho, Kwang Hwan; Huh, Hyun Do; Lim, Sangwook; Shin, Dongho
2015-07-01
The purpose of this study was to use various dosimetrical indices to determine the best intensitymodulated radiation therapy (IMRT) modality - for treating patients with prostate cancer. Ten patients with prostate cancer were included in this study. IMRT plans were designed to include different modalities, including the linac step and shoot, tomotherapy, RapidArc, and proton systems. Various dosimetrical indices, like the prescription isodose to target volume (PITV) ratio, conformity index (CI), homogeneity index (HI), target coverage index (TCI), modified dose homogeneity index (MHI), conformation number (CN), critical organ scoring index (COSI), and quality factor (QF), were determined to compare the different treatment plans. Biological indices, such as the generalized equivalent uniform dose (gEUD) based the tumor control probability (TCP), and the normal tissue complication probability (NTCP), were also calculated and used to compare the treatment plans. The RapidArc plan attained better PTV coverage, as evidenced by its superior PITV, CI, TCI, MHI, and CN values. Regarding organ at risks (OARs), proton therapy exhibited superior dose sparing for the rectum and the bowel in low dose volumes, whereas the tomotherapy and RapidArc plans achieved better dose sparing in high dose volumes. The QF scores showed no significant difference among these plans (p = 0.701). The average TCPs for prostate tumors in the RapidArc, linac and proton plans were higher than the average TCP for Tomotherapy (98.79%, 98.76%, and 98.75% vs. 98.70%, respectively). Regarding the rectum NTCP, RapidArc showed the most favorable result (0.09%) whereas linac resulted in the best bladder NTCP (0.08%).
SU-E-T-124: Dosimetric Comparison of HDR Brachytherapy and Intensity Modulated Proton Therapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wu, J; Wu, H; Das, I
2014-06-01
Purpose: Brachytherapy is known to be able to deliver more radiation dose to tumor while minimizing radiation dose to surrounding normal tissues. Proton therapy also provides superior dose distribution due to Bragg peak. Since both HDR and Intensity Modulated Proton Therapy (IMPT) are beneficial for their quick dose drop off, our goal in this study is to compare the pace of dose gradient drop-off between HDR and IMPT plans based on the same CT image data-set. In addition, normal tissues sparing were also compared among HDR, IMPT and SBRT. Methods: Five cervical cancer cases treated with EBRT + HDR boostmore » combination with Tandem and Ovoid applicator were used for comparison purpose. Original HDR plans with prescribed dose of 5.5 Gy x 5 fractions were generated and optimized. The 100% isodose line of HDR plans was converted to a dose volume, and treated as CTV for IMPT and SBRT planning. The same HDR CT scans were also used for IMPT plan and SBRT plan for direct comparison. The philosophy of the IMPT and SBRT planning was to create the same CTV coverage as HDR plans. All three modalities treatment plans were compared to each other with a set of predetermined criteria. Results: With similar target volume coverage in cervix cancer boost treatment, HDR provides a slightly sharper dose drop-off from 100% to 50% isodose line, averagely in all directions compared to IMPT. However, IMPT demonstrated more dose gradient drop-off at the junction of the target and normal tissues by providing more normal tissue sparing and superior capability to reduce integral dose. Conclusion: IMPT is capable of providing comparable dose drop-off as HDR. IMPT can be explored as replacement for HDR brachytherapy in various applications.« less
Evaluation of Larynx-Sparing Techniques With IMRT When Treating the Head and Neck
DOE Office of Scientific and Technical Information (OSTI.GOV)
Webster, Gareth J.; Rowbottom, Carl G.; Ho, Kean F.
2008-10-01
Purpose: Concern exists that widespread implementation of whole-field intensity-modulated radiotherapy (IMRT) for the treatment of head-and-neck cancer has resulted in increased levels of dysphagia relative to those seen with conventional planning. Other investigators have suggested an alternative junctioned-IMRT (J-IMRT) method, which matches an IMRT plan to a centrally blocked neck field to restrict the laryngeal dose and reduce dysphagia. The effect on target coverage and sparing of organs at risk, including laryngeal sparing, in the optimization was evaluated and compared with that achieved using a J-IMRT technique. Methods and Materials: A total of 13 oropharyngeal cancer whole-field IMRT plans weremore » planned with and without including laryngeal sparing in the optimization. A comparison of the target coverage and sparing of organs at risk was made using the resulting dose-volume histograms and dose distribution. The nine plans with disease located superior to the level of the larynx were replanned using a series of J-IMRT techniques to compare the two laryngeal-sparing techniques. Results: An average mean larynx dose of 29.1 Gy was achieved if disease did not extend to the level of the larynx, with 38.8 Gy for disease extending inferiorly and close to the larynx (reduced from 46.2 and 47.7 Gy, respectively, without laryngeal sparing). Additional laryngeal sparing could be achieved with J-IMRT (mean dose 24.4 Gy), although often at the expense of significantly reduced coverage of the target volume and with no improvement to other areas of the IMRT plan. Conclusion: The benefits of J-IMRT can be achieved with whole-field IMRT if laryngeal sparing is incorporated into the class solution. Inclusion of laryngeal sparing had no effect on other parameters in the plan.« less
Evaluation of different strategies for magnetic particle functionalization with DNA aptamers.
Pérez-Ruiz, Elena; Lammertyn, Jeroen; Spasic, Dragana
2016-12-25
The optimal bio-functionalization of magnetic particles is essential for developing magnetic particle-based bioassays. Whereas functionalization with antibodies is generally well established, immobilization of DNA probes, such as aptamers, is not yet fully explored. In this work, four different types of commercially available magnetic particles, coated with streptavidin, maleimide or carboxyl groups, were evaluated for their surface coverage with aptamer bioreceptors, efficiency in capturing target protein and non-specific protein adsorption on their surface. A recently developed aptamer against the peanut allergen, Ara h 1 protein, was used as a model system. Conjugation of biotinylated Ara h 1 aptamer to the streptavidin particles led to the highest surface coverage, whereas the coverage of maleimide particles was 25% lower. Carboxylated particles appeared to be inadequate for DNA functionalization. Streptavidin particles also showed the greatest target capturing efficiency, comparable to the one of particles functionalized with anti-Ara h 1 antibody. The performance of streptavidin particles was additionally tested in a sandwich assay with the aptamer as a capture receptor on the particle surface. While the limit of detection obtained was comparable to the same assay system with antibody as capture receptor, it was superior to previously reported values using the same aptamer in similar assay schemes with different detection platforms. These results point to the promising application of the Ara h 1 aptamer-functionalized particles in bioassay development. Copyright © 2016 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Calvo Ortega, Juan Francisco, E-mail: jfcdrr@yahoo.es; Wunderink, Wouter; Delgado, David
The aim of this study is to evaluate the setup margins from the clinical target volume (CTV) to planning target volume (PTV) for cranial stereotactic radiosurgery (SRS) treatments guided by cone beam computed tomography (CBCT). We designed an end-to-end (E2E) test using a skull phantom with an embedded 6mm tungsten ball (target). A noncoplanar plan was computed (E2E plan) to irradiate the target. The CBCT-guided positioning of the skull phantom on the linac was performed. Megavoltage portal images were acquired after 15 independent deliveries of the E2E plan. The displacement 2-dimensional (2D) vector between the centers of the square fieldmore » and the ball target on each portal image was used to quantify the isocenter accuracy. Geometrical margins on each patient's direction (left-right or LR, anterior-posterior or AP, superior-inferior or SI) were calculated. Dosimetric validation of the margins was performed in 5 real SRS cases: 3-dimesional (3D) isocenter deviations were mimicked, and changes in CTV dose coverage and organs-at-risk (OARs) dosage were analyzed. The CTV-PTV margins of 1.1 mm in LR direction, and 0.7 mm in AP and SI directions were derived from the E2E tests. The dosimetric analysis revealed that a 1-mm uniform margin was sufficient to ensure the CTV dose coverage, without compromising the OAR dose tolerances. The effect of isocenter uncertainty has been estimated to be 1 mm in our CBCT-guided SRS approach.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Jiahao, E-mail: mashenglin@medmail.com.cn; Li, Xiadong; Deng, Qinghua
2015-10-01
The purposes of this article were to compare the biophysical dosimetry for postmastectomy left-sided breast cancer using 4 different radiotherapy (RT) techniques. In total, 30 patients with left-sided breast cancer were randomly selected for this treatment planning study. They were planned using 4 RT techniques, including the following: (1) 3-dimensional conventional tangential fields (TFs), (2) tangential intensity-modulated therapy (T-IMRT), (3) 4 fields IMRT (4F-IMRT), and (4) single arc volumetric-modulated arc therapy (S-VMAT). The planning target volume (PTV) dose was prescribed 50 Gy, the comparison of target dose distribution, conformity index, homogeneity index, dose to organs at risk (OARs), tumor controlmore » probability (TCP), normal tissue complication probability (NTCP), and number of monitor units (MUs) between 4 plans were investigated for their biophysical dosimetric difference. The target conformity and homogeneity of S-VMAT were better than the other 3 kinds of plans, but increased the volume of OARs receiving low dose (V{sub 5}). TCP of PTV and NTCP of the left lung showed no statistically significant difference in 4 plans. 4F-IMRT plan was superior in terms of target coverage and protection of OARs and demonstrated significant advantages in decreasing the NTCP of heart by 0.07, 0.03, and 0.05 compared with TFs, T-IMRT, and S-VMAT plan. Compared with other 3 plans, TFs reduced the average number of MUs. Of the 4 techniques studied, this analysis supports 4F-IMRT as the most appropriate balance of target coverage and normal tissue sparing.« less
Chen, Yi-Jen; Liu, An; Han, Chunhui; Tsai, Peter T; Schultheiss, Timothy E; Pezner, Richard D; Vora, Nilesh; Lim, Dean; Shibata, Stephen; Kernstine, Kemp H; Wong, Jeffrey Y C
2007-01-01
We compare different radiotherapy techniques-helical tomotherapy (tomotherapy), step-and-shoot IMRT (IMRT), and 3-dimensional conformal radiotherapy (3DCRT)-for patients with mid-distal esophageal carcinoma on the basis of dosimetric analysis. Six patients with locally advanced mid-distal esophageal carcinoma were treated with neoadjuvant chemoradiation followed by surgery. Radiotherapy included 50 Gy to gross planning target volume (PTV) and 45 Gy to elective PTV in 25 fractions. Tomotherapy, IMRT, and 3DCRT plans were generated. Dose-volume histograms (DVHs), homogeneity index (HI), volumes of lung receiving more than 10, 15, or 20 Gy (V(10), V(15), V(20)), and volumes of heart receiving more than 30 or 45 Gy (V(30), V(45)) were determined. Statistical analysis was performed by paired t-tests. By isodose distributions and DVHs, tomotherapy plans showed sharper dose gradients, more conformal coverage, and better HI for both gross and elective PTVs compared with IMRT or 3DCRT plans. Mean V(20) of lung was significantly reduced in tomotherapy plans. However, tomotherapy and IMRT plans resulted in larger V(10) of lung compared to 3DCRT plans. The heart was significantly spared in tomotherapy and IMRT plans compared to 3DCRT plans in terms of V(30) and V(45). We conclude that tomotherapy plans are superior in terms of target conformity, dose homogeneity, and V(20) of lung.
Delineation of Supraclavicular Target Volumes in Breast Cancer Radiation Therapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brown, Lindsay C.; Diehn, Felix E.; Boughey, Judy C.
Purpose: To map the location of gross supraclavicular metastases in patients with breast cancer, in order to determine areas at highest risk of harboring subclinical disease. Methods and Materials: Patients with axial imaging of gross supraclavicular disease were identified from an institutional breast cancer registry. Locations of the metastatic lymph nodes were transferred onto representative axial computed tomography images of the supraclavicular region and compared with the Radiation Therapy Oncology Group (RTOG) breast cancer atlas for radiation therapy planning. Results: Sixty-two patients with 161 supraclavicular nodal metastases were eligible for study inclusion. At the time of diagnosis, 117 nodal metastasesmore » were present in 44 patients. Forty-four nodal metastases in 18 patients were detected at disease recurrence, 4 of whom had received prior radiation to the supraclavicular fossa. Of the 161 nodal metastases, 95 (59%) were within the RTOG consensus volume, 4 nodal metastases (2%) in 3 patients were marginally within the volume, and 62 nodal metastases (39%) in 30 patients were outside the volume. Supraclavicular disease outside the RTOG consensus volume was located in 3 regions: at the level of the cricoid and thyroid cartilage (superior to the RTOG volume), in the posterolateral supraclavicular fossa (posterolateral to the RTOG volume), and in the lateral low supraclavicular fossa (lateral to the RTOG volume). Only women with multiple supraclavicular metastases had nodal disease that extended superiorly to the level of the thyroid cartilage. Conclusions: For women with risk of harboring subclinical supraclavicular disease warranting the addition of supraclavicular radiation, coverage of the posterior triangle and the lateral low supraclavicular region should be considered. For women with known supraclavicular disease, extension of neck coverage superior to the cricoid cartilage may be warranted.« less
On Connected Target k-Coverage in Heterogeneous Wireless Sensor Networks.
Yu, Jiguo; Chen, Ying; Ma, Liran; Huang, Baogui; Cheng, Xiuzhen
2016-01-15
Coverage and connectivity are two important performance evaluation indices for wireless sensor networks (WSNs). In this paper, we focus on the connected target k-coverage (CTC k) problem in heterogeneous wireless sensor networks (HWSNs). A centralized connected target k-coverage algorithm (CCTC k) and a distributed connected target k-coverage algorithm (DCTC k) are proposed so as to generate connected cover sets for energy-efficient connectivity and coverage maintenance. To be specific, our proposed algorithms aim at achieving minimum connected target k-coverage, where each target in the monitored region is covered by at least k active sensor nodes. In addition, these two algorithms strive to minimize the total number of active sensor nodes and guarantee that each sensor node is connected to a sink, such that the sensed data can be forwarded to the sink. Our theoretical analysis and simulation results show that our proposed algorithms outperform a state-of-art connected k-coverage protocol for HWSNs.
Lovelock, D Michael; Messineo, Alessandra P; Cox, Brett W; Kollmeier, Marisa A; Zelefsky, Michael J
2015-03-01
To compare the potential benefits of continuous monitoring of prostate position and intervention (CMI) using 2-mm displacement thresholds during stereotactic body radiation therapy (SBRT) treatment to those of a conventional image-guided procedure involving single localization prior to treatment. Eighty-nine patients accrued to a prostate SBRT dose escalation protocol were implanted with radiofrequency transponder beacons. The planning target volume (PTV) margin was 5 mm in all directions, except for 3 mm in the posterior direction. The prostate was kept within 2 mm of its planned position by the therapists halting dose delivery and, if necessary, correcting the couch position. We computed the number, type, and time required for interventions and where the prostate would have been during dose delivery had there been, instead, a single image-guided setup procedure prior to each treatment. Distributions of prostate displacements were computed as a function of time. After the initial setup, 1.7 interventions per fraction were required, with a concomitant increase in time for dose delivery of approximately 65 seconds. Small systematic drifts in prostate position in the posterior and inferior directions were observed in the study patients. Without CMI, intrafractional motion would have resulted in approximately 10% of patients having a delivered dose that did not meet our clinical coverage requirement, that is, a PTV D95 of >90%. The posterior PTV margin required for 95% of the dose to be delivered with the target positioned within the PTV was computed as a function of time. The margin necessary was found to increase by 2 mm every 5 minutes, starting from the time of the imaging procedure. CMI using a tight 2-mm displacement threshold was not only feasible but was found to deliver superior PTV coverage compared with the conventional image-guided procedure in the SBRT setting. Copyright © 2015 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lovelock, D. Michael, E-mail: lovelocm@mskcc.org; Messineo, Alessandra P.; Cox, Brett W.
2015-03-01
Purpose: To compare the potential benefits of continuous monitoring of prostate position and intervention (CMI) using 2-mm displacement thresholds during stereotactic body radiation therapy (SBRT) treatment to those of a conventional image-guided procedure involving single localization prior to treatment. Methods and Materials: Eighty-nine patients accrued to a prostate SBRT dose escalation protocol were implanted with radiofrequency transponder beacons. The planning target volume (PTV) margin was 5 mm in all directions, except for 3 mm in the posterior direction. The prostate was kept within 2 mm of its planned position by the therapists halting dose delivery and, if necessary, correcting themore » couch position. We computed the number, type, and time required for interventions and where the prostate would have been during dose delivery had there been, instead, a single image-guided setup procedure prior to each treatment. Distributions of prostate displacements were computed as a function of time. Results: After the initial setup, 1.7 interventions per fraction were required, with a concomitant increase in time for dose delivery of approximately 65 seconds. Small systematic drifts in prostate position in the posterior and inferior directions were observed in the study patients. Without CMI, intrafractional motion would have resulted in approximately 10% of patients having a delivered dose that did not meet our clinical coverage requirement, that is, a PTV D95 of >90%. The posterior PTV margin required for 95% of the dose to be delivered with the target positioned within the PTV was computed as a function of time. The margin necessary was found to increase by 2 mm every 5 minutes, starting from the time of the imaging procedure. Conclusions: CMI using a tight 2-mm displacement threshold was not only feasible but was found to deliver superior PTV coverage compared with the conventional image-guided procedure in the SBRT setting.« less
Liang, Pingping; Canoura, Juan; Yu, Haixiang; Alkhamis, Obtin; Xiao, Yi
2018-01-31
DNA-modified gold nanoparticles (AuNPs) are useful signal-reporters for detecting diverse molecules through various hybridization- and enzyme-based assays. However, their performance is heavily dependent on the probe DNA surface coverage, which can influence both target binding and enzymatic processing of the bound probes. Current methods used to adjust the surface coverage of DNA-modified AuNPs require the production of multiple batches of AuNPs under different conditions, which is costly and laborious. We here develop a single-step assay utilizing dithiothreitol (DTT) to fine-tune the surface coverage of DNA-modified AuNPs. DTT is superior to the commonly used surface diluent, mercaptohexanol, as it is less volatile, allowing for the rapid and reproducible controlling of surface coverage on AuNPs with only micromolar concentrations of DTT. Upon adsorption, DTT forms a dense monolayer on gold surfaces, which provides antifouling capabilities. Furthermore, surface-bound DTT adopts a cyclic conformation, which reorients DNA probes into an upright position and provides ample space to promote DNA hybridization, aptamer assembly, and nuclease digestion. We demonstrate the effects of surface coverage on AuNP-based sensors using DTT-regulated DNA-modified AuNPs. We then use these AuNPs to visually detect DNA and cocaine in colorimetric assays based on enzyme-mediated AuNP aggregation. We determine that DTT-regulated AuNPs with lower surface coverage achieve shorter reaction times and lower detection limits relative to those for assays using untreated AuNPs or DTT-regulated AuNPs with high surface coverage. Additionally, we demonstrate that our DTT-regulated AuNPs can perform cocaine detection in 50% urine without any significant matrix effects. We believe that DTT regulation of surface coverage can be broadly employed for optimizing DNA-modified AuNP performance for use in biosensors as well as drug delivery and therapeutic applications.
Yang, Rendong; Nelson, Andrew C; Henzler, Christine; Thyagarajan, Bharat; Silverstein, Kevin A T
2015-12-07
Comprehensive identification of insertions/deletions (indels) across the full size spectrum from second generation sequencing is challenging due to the relatively short read length inherent in the technology. Different indel calling methods exist but are limited in detection to specific sizes with varying accuracy and resolution. We present ScanIndel, an integrated framework for detecting indels with multiple heuristics including gapped alignment, split reads and de novo assembly. Using simulation data, we demonstrate ScanIndel's superior sensitivity and specificity relative to several state-of-the-art indel callers across various coverage levels and indel sizes. ScanIndel yields higher predictive accuracy with lower computational cost compared with existing tools for both targeted resequencing data from tumor specimens and high coverage whole-genome sequencing data from the human NIST standard NA12878. Thus, we anticipate ScanIndel will improve indel analysis in both clinical and research settings. ScanIndel is implemented in Python, and is freely available for academic use at https://github.com/cauyrd/ScanIndel.
Cardiac-Sparing Whole Lung IMRT in Children With Lung Metastasis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kalapurakal, John A., E-mail: j-kalapurakal@northwestern.edu; Zhang, Yunkai; Kepka, Alan
Purpose: To demonstrate the dosimetric advantages of cardiac-sparing (CS) intensity modulated radiation therapy (IMRT) in children undergoing whole lung irradiation (WLI). Methods and Materials: Chest CT scans of 22 children who underwent simulation with 3-dimensional (n=10) or 4-dimensional (n=12) techniques were used for this study. Treatment planning was performed using standard anteroposterior-posteroanterior (S-RT) technique and CS-IMRT. Left and right flank fields were added to WLI fields to determine whether CS-IMRT offered any added protection to normal tissues at the junction between these fields. The radiation dose to the lung PTV, cardiac structures, liver, and thyroid were analyzed and compared. Results:more » CS-IMRT had 4 significant advantages over S-RT: (1) superior cardiac protection (2) superior 4-dimensional lung planning target volume coverage, (3) superior dose uniformity in the lungs with fewer hot spots, and (4) significantly lower dose to the heart when flank RT is administered after WLI. Conclusions: The use of CS-IMRT and 4-dimensional treatment planning has the potential to improve tumor control rates and reduce cardiac toxicity in children receiving WLI.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hong, C; Ju, S; Ahn, Y
2015-06-15
Purpose: To compare normal lung-sparing capabilities of three advanced radiation therapy techniques for locally advanced non-small cell lung cancer (LA-NSCLC). Methods: Four-dimensional computed tomography (4DCT) was performed in 10 patients with stage IIIb LA-NSCLC. The internal target volume (ITV); planning target volume (PTV); and organs at risks (OARs) such as spinal cord, total normal lung, heart, and esophagus were delineated for each CT data set. Intensity-modulated radiation therapy (IMRT), Tomohelical-IMRT (TH-IMRT), and TomoDirect-IMRT (TD-IMRT) plans were generated (total prescribed dose, 66 Gy in 33 fractions to the PTV) for each patient. To reduce the normal lung dose, complete and directionalmore » block function was applied outside the normal lung far from the target for both TH-IMRT and TD-IMRT, while pseudo- OAR was set in the same region for IMRT. Dosimetric characteristics of the three plans were compared in terms of target coverage, the sparing capability for the OAR, and the normal tissue complication probability (NTCP). Beam delivery efficiency was also compared. Results: TH-IMRT and TD-IMRT provided better target coverage than IMRT plans. Lung volume receiving ≥–30 Gy, mean dose, and NTCP were significant with TH-IMRT than with IMRT (p=0.006), and volume receiving ≥20–30 Gy was lower in TD-IMRT than in IMRT (p<0.05). Compared with IMRT, TH-IMRT had better sparing effect on the spinal cord (Dmax, NTCP) and heart (V45) (p<0.05). NTCP for the spinal cord, V45 and V60 for the heart, and Dmax for the esophagus were significantly lower in TD-IMRT than in IMRT. The monitor units per fraction were clearly smaller for IMRT than for TH-IMRT and TD-IMRT (p=0.006). Conclusion: In LA-NSCLC, TH-IMRT gave superior PTV coverage and OAR sparing compared to IMRT. TH-IMRT provided better control of the lung volume receiving ≥5–30 Gy. The delivery time and monitor units were lower in TD-IMRT than in TH-IMRT.« less
A compound chimeric antigen receptor strategy for targeting multiple myeloma.
Chen, K H; Wada, M; Pinz, K G; Liu, H; Shuai, X; Chen, X; Yan, L E; Petrov, J C; Salman, H; Senzel, L; Leung, E L H; Jiang, X; Ma, Y
2018-02-01
Current clinical outcomes using chimeric-antigen receptors (CARs) against multiple myeloma show promise in the eradication of bulk disease. However, these anti-BCMA (CD269) CARs observe relapse as a common phenomenon after treatment due to the reemergence of either antigen-positive or -negative cells. Hence, the development of improvements in CAR design to target antigen loss and increase effector cell persistency represents a critical need. Here, we report on the anti-tumor activity of a CAR T-cell possessing two complete and independent CAR receptors against the multiple myeloma antigens BCMA and CS1. We determined that the resulting compound CAR (cCAR) T-cell possesses consistent, potent and directed cytotoxicity against each target antigen population. Using multiple mouse models of myeloma and mixed cell populations, we are further able to show superior in vivo survival by directed cytotoxicity against multiple populations compared to a single-expressing CAR T-cell. These findings indicate that compound targeting of BCMA and CS1 on myeloma cells can potentially be an effective strategy for augmenting the response against myeloma bulk disease and for initiation of broader coverage CAR therapy.
Single-Isocenter Multiple-Target Stereotactic Radiosurgery: Risk of Compromised Coverage
DOE Office of Scientific and Technical Information (OSTI.GOV)
Roper, Justin, E-mail: justin.roper@emory.edu; Department of Biostatistics and Bioinformatics, Winship Cancer Institute of Emory University, Atlanta, Georgia; Chanyavanich, Vorakarn
2015-11-01
Purpose: To determine the dosimetric effects of rotational errors on target coverage using volumetric modulated arc therapy (VMAT) for multitarget stereotactic radiosurgery (SRS). Methods and Materials: This retrospective study included 50 SRS cases, each with 2 intracranial planning target volumes (PTVs). Both PTVs were planned for simultaneous treatment to 21 Gy using a single-isocenter, noncoplanar VMAT SRS technique. Rotational errors of 0.5°, 1.0°, and 2.0° were simulated about all axes. The dose to 95% of the PTV (D95) and the volume covered by 95% of the prescribed dose (V95) were evaluated using multivariate analysis to determine how PTV coverage was relatedmore » to PTV volume, PTV separation, and rotational error. Results: At 0.5° rotational error, D95 values and V95 coverage rates were ≥95% in all cases. For rotational errors of 1.0°, 7% of targets had D95 and V95 values <95%. Coverage worsened substantially when the rotational error increased to 2.0°: D95 and V95 values were >95% for only 63% of the targets. Multivariate analysis showed that PTV volume and distance to isocenter were strong predictors of target coverage. Conclusions: The effects of rotational errors on target coverage were studied across a broad range of SRS cases. In general, the risk of compromised coverage increased with decreasing target volume, increasing rotational error and increasing distance between targets. Multivariate regression models from this study may be used to quantify the dosimetric effects of rotational errors on target coverage given patient-specific input parameters of PTV volume and distance to isocenter.« less
Lu, Jia-Yang; Cheung, Michael Lok-Man; Huang, Bao-Tian; Wu, Li-Li; Xie, Wen-Jia; Chen, Zhi-Jian; Li, De-Rui; Xie, Liang-Xi
2015-01-01
To assess the performance of a simple optimisation method for improving target coverage and organ-at-risk (OAR) sparing in intensity-modulated radiotherapy (IMRT) for cervical oesophageal cancer. For 20 selected patients, clinically acceptable original IMRT plans (Original plans) were created, and two optimisation methods were adopted to improve the plans: 1) a base dose function (BDF)-based method, in which the treatment plans were re-optimised based on the original plans, and 2) a dose-controlling structure (DCS)-based method, in which the original plans were re-optimised by assigning additional constraints for hot and cold spots. The Original, BDF-based and DCS-based plans were compared with regard to target dose homogeneity, conformity, OAR sparing, planning time and monitor units (MUs). Dosimetric verifications were performed and delivery times were recorded for the BDF-based and DCS-based plans. The BDF-based plans provided significantly superior dose homogeneity and conformity compared with both the DCS-based and Original plans. The BDF-based method further reduced the doses delivered to the OARs by approximately 1-3%. The re-optimisation time was reduced by approximately 28%, but the MUs and delivery time were slightly increased. All verification tests were passed and no significant differences were found. The BDF-based method for the optimisation of IMRT for cervical oesophageal cancer can achieve significantly better dose distributions with better planning efficiency at the expense of slightly more MUs.
A Max-Flow Based Algorithm for Connected Target Coverage with Probabilistic Sensors
Shan, Anxing; Xu, Xianghua; Cheng, Zongmao; Wang, Wensheng
2017-01-01
Coverage is a fundamental issue in the research field of wireless sensor networks (WSNs). Connected target coverage discusses the sensor placement to guarantee the needs of both coverage and connectivity. Existing works largely leverage on the Boolean disk model, which is only a coarse approximation to the practical sensing model. In this paper, we focus on the connected target coverage issue based on the probabilistic sensing model, which can characterize the quality of coverage more accurately. In the probabilistic sensing model, sensors are only be able to detect a target with certain probability. We study the collaborative detection probability of target under multiple sensors. Armed with the analysis of collaborative detection probability, we further formulate the minimum ϵ-connected target coverage problem, aiming to minimize the number of sensors satisfying the requirements of both coverage and connectivity. We map it into a flow graph and present an approximation algorithm called the minimum vertices maximum flow algorithm (MVMFA) with provable time complex and approximation ratios. To evaluate our design, we analyze the performance of MVMFA theoretically and also conduct extensive simulation studies to demonstrate the effectiveness of our proposed algorithm. PMID:28587084
A Max-Flow Based Algorithm for Connected Target Coverage with Probabilistic Sensors.
Shan, Anxing; Xu, Xianghua; Cheng, Zongmao; Wang, Wensheng
2017-05-25
Coverage is a fundamental issue in the research field of wireless sensor networks (WSNs). Connected target coverage discusses the sensor placement to guarantee the needs of both coverage and connectivity. Existing works largely leverage on the Boolean disk model, which is only a coarse approximation to the practical sensing model. In this paper, we focus on the connected target coverage issue based on the probabilistic sensing model, which can characterize the quality of coverage more accurately. In the probabilistic sensing model, sensors are only be able to detect a target with certain probability. We study the collaborative detection probability of target under multiple sensors. Armed with the analysis of collaborative detection probability, we further formulate the minimum ϵ -connected target coverage problem, aiming to minimize the number of sensors satisfying the requirements of both coverage and connectivity. We map it into a flow graph and present an approximation algorithm called the minimum vertices maximum flow algorithm (MVMFA) with provable time complex and approximation ratios. To evaluate our design, we analyze the performance of MVMFA theoretically and also conduct extensive simulation studies to demonstrate the effectiveness of our proposed algorithm.
NASA Astrophysics Data System (ADS)
Moteabbed, M.; Trofimov, A.; Sharp, G. C.; Wang, Y.; Zietman, A. L.; Efstathiou, J. A.; Lu, H.-M.
2017-03-01
Proton therapy of prostate by anterior beams could offer an attractive option for treating patients with hip prosthesis and limiting the high-dose exposure to the rectum. We investigated the impact of setup and anatomy variations on the anterior-oblique (AO) proton plan dose, and strategies to manage these effects via range verification and adaptive delivery. Ten patients treated by bilateral (BL) passive-scattering proton therapy (79.2 Gy in 44 fractions) who underwent weekly verification CT scans were selected. Plans with AO beams were additionally created. To isolate the effect of daily variations, initial AO plans did not include range uncertainty margins. The use of fixed planning margins and adaptive range adjustments to manage these effects was investigated. For each case, the planned dose was recalculated on weekly CTs, and accumulated on the simulation CT using deformable registration to approximate the delivered dose. Planned and accumulated doses were compared for each scenario to quantify dose deviations induced by variations. The possibility of estimating the necessary range adjustments before each treatment was explored by simulating the procedure of a diode-based in vivo range verification technique, which would potentially be used clinically. The average planned rectum, penile bulb and femoral heads mean doses were smaller for initial AO compared to BL plans (by 8.3, 16.1 and 25.9 Gy, respectively). After considering interfractional variations in AO plans, the target coverage was substantially reduced. The maximum reduction of V 79.2/D 95/D mean/EUD for AO (without distal margins) (25.3%/10.7/1.6/4.9 Gy, respectively) was considerably larger than BL plans. The loss of coverage was mainly related to changes in water equivalent path length of the prostate after fiducial-based setup, caused by discrepancies in patient anterior surface and bony-anatomy alignment. Target coverage was recovered partially when using fixed planning margins, and fully when applying adaptive range adjustments. The accumulated organs-at-risk dose for AO beams after range adjustment demonstrated full sparing of femoral heads and superior sparing of penile bulb and rectum compared to the conventional BL cases. Our study indicates that using AO beams makes prostate treatment more susceptible to target underdose induced by interfractional variations. Adaptive range verification/adjustment may facilitate the use of anterior beam approaches, and ensure adequate target coverage in every fraction of the treatment.
NASA Astrophysics Data System (ADS)
Yang, Deshan; Li, H. Harold; Goddu, S. Murty; Tan, Jun
2014-10-01
Onboard cone-beam CT (CBCT) has been widely used in image guided radiation therapy. However, the longitudinal coverage is only 15.5 cm in the pelvis scan mode. As a result, a single CBCT scan cannot cover the planning target volume in the longitudinal direction for over 80% of the patients. The common approach is to use double- or multiple-circular scans and then combine multiple CBCT volumes after reconstruction. However it raises concerns regarding doubled imaging dose at the imaging beam junctions due to beam divergence. In this work, we present a new method, DSCS (Dual Scan with Complementary Shifts), to address the CBCT coverage problem using a pair of complementary circular scans. In DSCS, two circular scans were performed at 39.5 cm apart longitudinally. In the superior scan, the detector panel was offset by 16 cm to the left, 15 cm to the inferior. In the inferior scan, the detector panel was shifted 16 cm to the right and 15 cm to the superior. The effective imaging volume is 39.5 cm longitudinally with a 45 cm lateral field-of-view (FOV). Half beam blocks were used to confine the imaging radiation inside the volume of interest. A new image reconstruction algorithm was developed, based on the Feldkamp-Davis-Kress cone-beam CT reconstruction algorithm, to support the DSCS scanning geometry. Digital phantom simulations were performed to demonstrate the feasibility of DSCS. Physical phantom studies were performed using an anthropomorphic phantom on a commercial onboard CBCT system. With basic scattering corrections, the reconstruction results were acceptable. Other issues, including the discrepancy in couch vertical at different couch longitudinal positions, and the inaccuracy in couch table longitudinal movement, were manually corrected during the reconstruction process. In conclusion, the phantom studies showed that, using DSCS, a 39.5 cm longitudinal coverage with a 45 cm FOV was accomplished. The efficiency of imaging dose usage was near 100%. This proposed method could be potentially useful for image guidance and subsequent treatment plan adaptation.
Feiring, Berit; Laake, Ida; Molden, Tor; Håberg, Siri E; Nøkleby, Hanne; Seterelv, Siri Schøyen; Magnus, Per; Trogstad, Lill
2016-04-12
Selective immunisation is an alternative to universal vaccination if children at increased risk of disease can be identified. Within the Norwegian Childhood Immunisation Programme, BCG vaccine against tuberculosis and vaccine against hepatitis B virus (HBV) are offered only to children with parents from countries with high burden of the respective disease. We wanted to study whether this selective immunisation policy reaches the targeted groups. The study population was identified through the Norwegian Central Population Registry and consisted of all children born in Norway 2007-2010 and residing in Norway until their second birthday, in total 240,484 children. Information on vaccinations from the Norwegian Immunisation Registry, and on parental country of birth from Statistics Norway, was linked to the population registry by personal identifiers. The coverage of BCG and HBV vaccine was compared with the coverage of vaccines in the universal programme. Among the study population, 16.1% and 15.9% belonged to the target groups for BCG and HBV vaccine, respectively. Among children in the BCG target group the BCG vaccine coverage was lower than the coverage of pertussis and measles vaccine (83.6% vs. 98.6% and 92.3%, respectively). Likewise, the HBV vaccine coverage was lower than the coverage of pertussis and measles vaccine in the HBV target group (90.0% vs. 98.6% and 92.3%, respectively). The coverage of the targeted vaccines was highest among children with parents from South Asia and Sub-Saharan Africa. The coverage of vaccines in the universal programme was similar in targeted and non-targeted groups. Children targeted by selective vaccination had lower coverage of the target vaccines than of vaccines in the universal programme, indicating that selective vaccination is challenging. Improved routines for identifying eligible children and delivering the target vaccines are needed. Universal vaccination of all children with these vaccines could be considered. Copyright © 2016 Elsevier Ltd. All rights reserved.
MO-FG-CAMPUS-TeP2-04: Optimizing for a Specified Target Coverage Probability
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fredriksson, A
2016-06-15
Purpose: The purpose of this work is to develop a method for inverse planning of radiation therapy margins. When using this method the user specifies a desired target coverage probability and the system optimizes to meet the demand without any explicit specification of margins to handle setup uncertainty. Methods: The method determines which voxels to include in an optimization function promoting target coverage in order to achieve a specified target coverage probability. Voxels are selected in a way that retains the correlation between them: The target is displaced according to the setup errors and the voxels to include are selectedmore » as the union of the displaced target regions under the x% best scenarios according to some quality measure. The quality measure could depend on the dose to the considered structure alone or could depend on the dose to multiple structures in order to take into account correlation between structures. Results: A target coverage function was applied to the CTV of a prostate case with prescription 78 Gy and compared to conventional planning using a DVH function on the PTV. Planning was performed to achieve 90% probability of CTV coverage. The plan optimized using the coverage probability function had P(D98 > 77.95 Gy) = 0.97 for the CTV. The PTV plan using a constraint on minimum DVH 78 Gy at 90% had P(D98 > 77.95) = 0.44 for the CTV. To match the coverage probability optimization, the DVH volume parameter had to be increased to 97% which resulted in 0.5 Gy higher average dose to the rectum. Conclusion: Optimizing a target coverage probability is an easily used method to find a margin that achieves the desired coverage probability. It can lead to reduced OAR doses at the same coverage probability compared to planning with margins and DVH functions.« less
Gao, Min; Li, Qilin; Ning, Zhonghua; Gu, Wendong; Huang, Jin; Mu, Jinming; Pei, Honglei
2016-01-01
To compare and analyze the dosimetric characteristics of volumetric modulated arc therapy (VMAT) vs step-shoot intensity-modulated radiation therapy (sIMRT) for upper thoracic and cervical esophageal carcinoma. Single-arc VMAT (VMAT1), dual-arc VMAT (VMAT2), and 7-field sIMRT plans were designed for 30 patients with upper thoracic or cervical esophageal carcinoma. Planning target volume (PTV) was prescribed to 50.4Gy in 28 fractions, and PTV1 was prescribed to 60Gy in 28 fractions. The parameters evaluated included dose homogeneity and conformality, dose to organs at risk (OARs), and delivery efficiency. (1) In comparison to sIMRT, VMAT provided a systematic improvement in PTV1 coverage. The homogeneity index of VMAT1 was better than that of VMAT2. There were no significant differences among sIMRT, VMAT1, and VMAT2 in PTV coverage. (2) VMAT1 and VMAT2 reduced the maximum dose of spinal cord as compared with sIMRT (p < 0.05). The rest dose-volume characteristics of OARs were similar. (3) Monitor units of VMAT2 and VMAT1 were more than sIMRT. However, the treatment time of VMAT1, VMAT2, and sIMRT was (2.0 ± 0.2), (2.8 ± 0.3), and (9.8 ± 0.8) minutes, respectively. VMAT1 was the fastest, and the difference was statistically significant. In the treatment of upper thoracic and cervical esophageal carcinoma by the AXESSE linac, compared with 7-field sIMRT, VMAT showed better PTV1 coverage and superior spinal cord sparing. Single-arc VMAT had similar target volume coverage and the sparing of OAR to dual-arc VMAT, with shortest treatment time and highest treatment efficiency in the 3 kinds of plans. Copyright © 2016 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gao, Min; Li, Qilin; Ning, Zhonghua
2016-07-01
To compare and analyze the dosimetric characteristics of volumetric modulated arc therapy (VMAT) vs step-shoot intensity-modulated radiation therapy (sIMRT) for upper thoracic and cervical esophageal carcinoma. Single-arc VMAT (VMAT1), dual-arc VMAT (VMAT2), and 7-field sIMRT plans were designed for 30 patients with upper thoracic or cervical esophageal carcinoma. Planning target volume (PTV) was prescribed to 50.4 Gy in 28 fractions, and PTV1 was prescribed to 60 Gy in 28 fractions. The parameters evaluated included dose homogeneity and conformality, dose to organs at risk (OARs), and delivery efficiency. (1) In comparison to sIMRT, VMAT provided a systematic improvement in PTV1 coverage.more » The homogeneity index of VMAT1 was better than that of VMAT2. There were no significant differences among sIMRT, VMAT1, and VMAT2 in PTV coverage. (2) VMAT1 and VMAT2 reduced the maximum dose of spinal cord as compared with sIMRT (p < 0.05). The rest dose-volume characteristics of OARs were similar. (3) Monitor units of VMAT2 and VMAT1 were more than sIMRT. However, the treatment time of VMAT1, VMAT2, and sIMRT was (2.0 ± 0.2), (2.8 ± 0.3), and (9.8 ± 0.8) minutes, respectively. VMAT1 was the fastest, and the difference was statistically significant. In the treatment of upper thoracic and cervical esophageal carcinoma by the AXESSE linac, compared with 7-field sIMRT, VMAT showed better PTV1 coverage and superior spinal cord sparing. Single-arc VMAT had similar target volume coverage and the sparing of OAR to dual-arc VMAT, with shortest treatment time and highest treatment efficiency in the 3 kinds of plans.« less
NASA Astrophysics Data System (ADS)
Jones, Bernard L.; Gan, Gregory; Kavanagh, Brian; Miften, Moyed
2013-11-01
An inflatable endorectal balloon (ERB) is often used during stereotactic body radiation therapy (SBRT) for treatment of prostate cancer in order to reduce both intrafraction motion of the target and risk of rectal toxicity. However, the ERB can exert significant force on the prostate, and this work assessed the impact of ERB position errors on deformation of the prostate and treatment dose metrics. Seventy-one cone-beam computed tomography (CBCT) image datasets of nine patients with clinical stage T1cN0M0 prostate cancer were studied. An ERB (Flexi-Cuff, EZ-EM, Westbury, NY) inflated with 60 cm3 of air was used during simulation and treatment, and daily kilovoltage (kV) CBCT imaging was performed to localize the prostate. The shape of the ERB in each CBCT was analyzed to determine errors in position, size, and shape. A deformable registration algorithm was used to track the dose received by (and deformation of) the prostate, and dosimetric values such as D95, PTV coverage, and Dice coefficient for the prostate were calculated. The average balloon position error was 0.5 cm in the inferior direction, with errors ranging from 2 cm inferiorly to 1 cm superiorly. The prostate was deformed primarily in the AP direction, and tilted primarily in the anterior-posterior/superior-inferior plane. A significant correlation was seen between errors in depth of ERB insertion (DOI) and mean voxel-wise deformation, prostate tilt, Dice coefficient, and planning-to-treatment prostate inter-surface distance (p < 0.001). Dosimetrically, DOI is negatively correlated with prostate D95 and PTV coverage (p < 0.001). For the model of ERB studied, error in ERB position can cause deformations in the prostate that negatively affect treatment, and this additional aspect of setup error should be considered when ERBs are used for prostate SBRT. Before treatment, the ERB position should be verified, and the ERB should be adjusted if the error is observed to exceed tolerable values.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bejarano Buele, A; Parsai, E
Purpose: The target volume for Whole Breast Irradiation (WBI) is dictated by location of tumor mass, breast tissue distribution, and involvement of lymph nodes. Dose coverage and Organs at Risk (OARs) sparing can be difficult to achieve in patients with unfavorable thoracic geometries. For these cases, inverse-planned and 3D-conformal prone treatments can be alternatives to traditional supine 3D-conformal plans. A dosimetric comparison can determine which of these techniques achieve optimal target coverage while sparing OARs. Methods: This study included simulation datasets for 8 patients, 5 of whom were simulated in both supine and prone positions. Positioning devices included breast boardsmore » and Vaclok bags for the supine position, and prone breast boards for the prone position. WBI 3-D conformal plans were created for patients simulated in both positions. Additional VMAT and IMRT WBI plans were made for all patients in the supine position. Results: Prone and supine 3D conformal plans had comparable PTV coverage. Prone 3D conformal plans received a significant 50% decrease to V20, V10, V5 and V30% for the ipsilateral lung in contrast to the supine plans. The heart also experienced a 10% decrease in maximum dose in the prone position, and V20, V10, V5 and V2 had significantly lower values than the supine plan. Supine IMRT and VMAT breast plans obtained comparable PTV coverage. The heart experienced a 10% decrease in maximum dose with inverse modulated plans when compared to the supine 3D conformal plan, while V20, V10, V5 and V2 showed higher values with inverse modulated plans than with supine 3D conformal plans. Conclusion: Prone 3D-conformal, and supine inverse planned treatments were generally superior in sparing OARs to supine plans with comparable PTV coverage. IMRT and VMAT plans offer sparing of OARs from high dose regions with an increase of irradiated volume in the low dose regions.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hepel, Jaroslaw T.; Department of Radiation Oncology, Brown University, Rhode Island Hospital, Providence, RI; Evans, Suzanne B.
2009-06-01
Purpose: To evaluate the accuracy of two clinical techniques for electron boost planning compared with computed tomography (CT)-based planning. Additionally, we evaluated the tumor bed characteristics at whole breast planning and boost planning. Methods and Materials: A total of 30 women underwent tumor bed boost planning within 2 weeks of completing whole breast radiotherapy using three planning techniques: scar-based planning, palpation/clinical-based planning, and CT-based planning. The plans were analyzed for dosimetric coverage of the CT-delineated tumor bed. The cavity visualization score was used to define the CT-delineated tumor bed as well or poorly defined. Results: Scar-based planning resulted in inferiormore » tumor bed coverage compared with CT-based planning, with the minimal dose received by 90% of the target volume >90% in 53% and a geographic miss in 53%. The results of palpation/clinical-based planning were significantly better: 87% and 10% for the minimal dose received by 90% of the target volume >90% and geographic miss, respectively. Of the 30 tumor beds, 16 were poorly defined by the cavity visualization score. Of these 16, 8 were well demarcated by the surgical clips. The evaluation of the 22 well-defined tumor beds revealed similar results. A comparison of the tumor bed volume from the initial planning CT scan to the boost planning CT scan revealed a decrease in size in 77% of cases. The mean decrease in volume was 52%. Conclusion: The results of our study have shown that CT-based planning allows for optimal tumor bed coverage compared with clinical and scar-based approaches. However, in the setting of a poorly visualized cavity on CT without surgical clips, palpation/clinical-based planning can help delineate the appropriate target volumes and is superior to scar-based planning. CT simulation at boost planning could allow for a reduction in the boost volumes.« less
Nicolini, G; Abraham, S; Fogliata, A; Jordaan, A; Clivio, A; Vanetti, E; Cozzi, L
2013-03-01
To evaluate the use of volumetric-modulated arc therapy [VMAT, RapidArc® (RA); Varian Medical Systems, Palo Alto, CA] for the treatment of cutaneous Kaposi's sarcoma (KS) of lower extremities with adequate target coverage and high bone sparing, and to compare VMAT with electron beam therapy. 10 patients were planned with either RA or electron beams. The dose was prescribed to 30 Gy, 10 fractions, to mean the planning target volume (PTV), and significant maximum dose to bone was limited to 30 Gy. Plans were designed for 6-MV photon beams for RA and 6 MeV for electrons. Dose distributions were computed with AcurosXB® (Varian Medical Systems) for photons and with a Monte Carlo algorithm for electrons. V(90%) was 97.3±1.2 for RA plans and 78.2±2.6 for electrons; similarly, V(107%) was 2.5±2.2 and 37.7±3.4, respectively. RA met coverage criteria. Concerning bone sparing, D(2%) was 29.6±1.1 for RA and 31.0±2.4 for electrons. Although acceptable for bone involvement, pronounced target coverage violations were obtained for electron plans. Monitor units were similar for electrons and RA, although for the latter they increased when superior bone sparing was imposed. Delivery times were 12.1±4.0 min for electrons and 4.8±1.3 min for the most modulated RA plans. High plan quality was shown for KS in the lower extremities using VMAT, and this might simplify their management in comparison with the more conventional usage of electrons, particularly in institutes with limited staff resources and heavy workloads. VMAT is also dosimetrically extremely advantageous in a typology of treatments where electron beam therapy is mainly considered to be effective owing to the limited penetration of the beams.
Chen, Hua; Wang, Hao; Gu, Hengle; Shao, Yan; Cai, Xuwei; Fu, Xiaolong; Xu, Zhiyong
2017-10-27
This study aimed to investigate the dosimetric differences and lung sparing between volumetric-modulated arc therapy (VMAT) and intensity-modulated radiation therapy (IMRT) in the treatment of upper thoracic esophageal cancer with T3N0M0 for preoperative radiotherapy by auto-planning (AP). Sixteen patient cases diagnosed with upper thoracic esophageal cancer T3N0M0 for preoperative radiotherapy were retrospectively studied, and 3 plans were generated for each patient: full arc VMAT AP plan with double arcs, partial arc VMAT AP plan with 6 partial arcs, and conventional IMRT AP plan. A simultaneous integrated boost with 2 levels was planned in all patients. Target coverage, organ at risk sparing, treatment parameters including monitor units and treatment time (TT) were evaluated. Wilcoxon signed-rank test was used to check for significant differences (p < 0.05) between datasets. VMAT plans (pVMAT and fVMAT) significantly reduced total lung volume treated above 20 Gy (V 20 ), 25 Gy (V 25 ), 30 Gy (V 30 ), 35 Gy (V 35 ), 40 Gy (V 40 ), and without increasing the value of V 10 , V 13 , and V 15 . For V 5 of total lung value, pVMAT was similar to aIMRT, and it was better than fVMAT. Both pVMAT and fVMAT improved the target dose coverage and significantly decreased maximum dose for the spinal cord, monitor unit, and TT. No significant difference was observed with respect to V 10 and V 15 of body. VMAT AP plan was a good option for treating upper thoracic esophageal cancer with T3N0M0, especially partial arc VMAT AP plan. It had the potential to effectively reduce lung dose in a shorter TT and with superior target coverage and dose homogeneity. Copyright © 2017 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.
Racial and Ethnic Disparities in Services and the Patient Protection and Affordable Care Act
Abdus, Salam; Mistry, Kamila B.
2015-01-01
Objectives. We examined prereform patterns in insurance coverage, access to care, and preventive services use by race/ethnicity in adults targeted by the coverage expansions of the Patient Protection and Affordable Care Act (ACA). Methods. We used pre-ACA household data from the Medical Expenditure Panel Survey to identify groups targeted by the coverage provisions of the Act (Medicaid expansions and subsidized Marketplace coverage). We examined racial/ethnic differences in coverage, access to care, and preventive service use, across and within ACA relevant subgroups from 2005 to 2010. The study took place at the Agency for Healthcare Research and Quality in Rockville, Maryland. Results. Minorities were disproportionately represented among those targeted by the coverage provisions of the ACA. Targeted groups had lower rates of coverage, access to care, and preventive services use, and racial/ethnic disparities were, in some cases, widest within these targeted groups. Conclusions. Our findings highlighted the opportunity of the ACA to not only to improve coverage, access, and use for all racial/ethnic groups, but also to narrow racial/ethnic disparities in these outcomes. Our results might have particular importance for states that are deciding whether to implement the ACA Medicaid expansions. PMID:26447920
Racial and Ethnic Disparities in Services and the Patient Protection and Affordable Care Act.
Abdus, Salam; Mistry, Kamila B; Selden, Thomas M
2015-11-01
We examined prereform patterns in insurance coverage, access to care, and preventive services use by race/ethnicity in adults targeted by the coverage expansions of the Patient Protection and Affordable Care Act (ACA). We used pre-ACA household data from the Medical Expenditure Panel Survey to identify groups targeted by the coverage provisions of the Act (Medicaid expansions and subsidized Marketplace coverage). We examined racial/ethnic differences in coverage, access to care, and preventive service use, across and within ACA relevant subgroups from 2005 to 2010. The study took place at the Agency for Healthcare Research and Quality in Rockville, Maryland. Minorities were disproportionately represented among those targeted by the coverage provisions of the ACA. Targeted groups had lower rates of coverage, access to care, and preventive services use, and racial/ethnic disparities were, in some cases, widest within these targeted groups. Our findings highlighted the opportunity of the ACA to not only to improve coverage, access, and use for all racial/ethnic groups, but also to narrow racial/ethnic disparities in these outcomes. Our results might have particular importance for states that are deciding whether to implement the ACA Medicaid expansions.
Rahpeyma, Amin; khajehahmadi, Saeedeh
2015-01-01
Introduction Reconstruction of oral and pharyngeal defects after pathologic resections with the same tissue is an optimal and ideal target. Islanded variety of inferiorly pedicled facial artery musculomucosal flap, in which facial artery and vein are skeletonized (referred to as inferiorly based BUMIF), is suitable for reconstruction of medium-sized mucosal defects. Presentation of cases In this article, with four cases, modifications of this flap are demonstrated in reconstruction of large intraoral and oropharyngeal defects and coverage of alveolar ridge in the mandible. Discussion In some situations, there is a need for more mucosal paddle, longer vascular pedicle and more adaptation to the recipient bed. Conclusion Relocating Stensen’s duct increases the mucosal paddle with cranial extension of superior limit while differential incision of the mucosa and buccinator muscle in mandibular vestibule extend the lower limit of this flap. Bone suture is a good complementary technique when this flap is used for coverage of mandibular alveolar ridge. Inferiorly based BUMIF with added length is indicated for oropharyngeal and contralateral mouth floor reconstructions. PMID:26218177
A comprehensive comparison of IMRT and VMAT plan quality for prostate cancer treatment
QUAN, ENZHUO M.; LI, XIAOQIANG; LI, YUPENG; WANG, XIAOCHUN; KUDCHADKER, RAJAT J.; JOHNSON, JENNIFER L.; KUBAN, DEBORAH A.; LEE, ANDREW K.; ZHANG, XIAODONG
2013-01-01
Purpose We performed a comprehensive comparative study of the plan quality between volumetric modulated arc therapy (VMAT) and intensity-modulated radiation therapy (IMRT) for the treatment of prostate cancer. Methods and Materials Eleven patients with prostate cancer treated at our institution were randomly selected for this study. For each patient, a VMAT plan and a series of IMRT plans using an increasing number of beams (8, 12, 16, 20, and 24 beams) were examined. All plans were generated using our in-house-developed automatic inverse planning (AIP) algorithm. An existing 8-beam clinical IMRT plan, which was used to treat the patient, was used as the reference plan. For each patient, all AIP-generated plans were optimized to achieve the same level of planning target volume (PTV) coverage as the reference plan. Plan quality was evaluated by measuring mean dose to and dose-volume statistics of the organs-at-risk, especially the rectum, from each type of plan. Results For the same PTV coverage, the AIP-generated VMAT plans had significantly better plan quality in terms of rectum sparing than the 8-beam clinical and AIP-generated IMRT plans (p < 0.0001). However, the differences between the IMRT and VMAT plans in all the dosimetric indices decreased as the number of beams used in IMRT increased. IMRT plan quality was similar or superior to that of VMAT when the number of beams in IMRT was increased to a certain number, which ranged from 12 to 24 for the set of patients studied. The superior VMAT plan quality resulted in approximately 30% more monitor units than the 8-beam IMRT plans, but the delivery time was still less than 3 minutes. Conclusions Considering the superior plan quality as well as the delivery efficiency of VMAT compared with that of IMRT, VMAT may be the preferred modality for treating prostate cancer. PMID:22704703
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, Min-Joo; Park, So-Hyun; Research Institute of Biomedical Engineering, The Catholic University of Korea, Seoul
2013-10-01
The partial-breast irradiation (PBI) technique, an alternative to whole-breast irradiation, is a beam delivery method that uses a limited range of treatment volume. The present study was designed to determine the optimal PBI treatment modalities for 8 different tumor locations. Treatment planning was performed on computed tomography (CT) data sets of 6 patients who had received lumpectomy treatments. Tumor locations were classified into 8 subsections according to breast quadrant and depth. Three-dimensional conformal radiation therapy (3D-CRT), electron beam therapy (ET), and helical tomotherapy (H-TOMO) were utilized to evaluate the dosimetric effect for each tumor location. Conformation number (CN), radical dosemore » homogeneity index (rDHI), and dose delivered to healthy tissue were estimated. The Kruskal-Wallis, Mann-Whitney U, and Bonferroni tests were used for statistical analysis. The ET approach showed good sparing effects and acceptable target coverage for the lower inner quadrant—superficial (LIQ-S) and lower inner quadrant—deep (LIQ-D) locations. The H-TOMO method was the least effective technique as no evaluation index achieved superiority for all tumor locations except CN. The ET method is advisable for treating LIQ-S and LIQ-D tumors, as opposed to 3D-CRT or H-TOMO, because of acceptable target coverage and much lower dose applied to surrounding tissue.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kozak, Kevin R.; Adams, Judith; Krejcarek, Stephanie J.
Purpose: We compared tumor and normal tissue dosimetry of proton radiation therapy with intensity-modulated radiation therapy (IMRT) for pediatric parameningeal rhabdomyosarcomas (PRMS). Methods and Materials: To quantify dosimetric differences between contemporary proton and photon treatment for pediatric PRMS, proton beam plans were compared with IMRT plans. Ten patients treated with proton radiation therapy at Massachusetts General Hospital had IMRT plans generated. To facilitate dosimetric comparisons, clinical target volumes and normal tissue volumes were held constant. Plans were optimized for target volume coverage and normal tissue sparing. Results: Proton and IMRT plans provided acceptable and comparable target volume coverage, with atmore » least 99% of the CTV receiving 95% of the prescribed dose in all cases. Improved dose conformality provided by proton therapy resulted in significant sparing of all examined normal tissues except for ipsilateral cochlea and mastoid; ipsilateral parotid gland sparing was of borderline statistical significance (p = 0.05). More profound sparing of contralateral structures by protons resulted in greater dose asymmetry between ipsilateral and contralateral retina, optic nerves, cochlea, and mastoids; dose asymmetry between ipsilateral and contralateral parotids was of borderline statistical significance (p = 0.05). Conclusions: For pediatric PRMS, superior normal tissue sparing is achieved with proton radiation therapy compared with IMRT. Because of enhanced conformality, proton plans also demonstrate greater normal tissue dose distribution asymmetry. Longitudinal studies assessing the impact of proton radiotherapy and IMRT on normal tissue function and growth symmetry are necessary to define the clinical consequences of these differences.« less
Coverage-based constraints for IMRT optimization
NASA Astrophysics Data System (ADS)
Mescher, H.; Ulrich, S.; Bangert, M.
2017-09-01
Radiation therapy treatment planning requires an incorporation of uncertainties in order to guarantee an adequate irradiation of the tumor volumes. In current clinical practice, uncertainties are accounted for implicitly with an expansion of the target volume according to generic margin recipes. Alternatively, it is possible to account for uncertainties by explicit minimization of objectives that describe worst-case treatment scenarios, the expectation value of the treatment or the coverage probability of the target volumes during treatment planning. In this note we show that approaches relying on objectives to induce a specific coverage of the clinical target volumes are inevitably sensitive to variation of the relative weighting of the objectives. To address this issue, we introduce coverage-based constraints for intensity-modulated radiation therapy (IMRT) treatment planning. Our implementation follows the concept of coverage-optimized planning that considers explicit error scenarios to calculate and optimize patient-specific probabilities q(\\hat{d}, \\hat{v}) of covering a specific target volume fraction \\hat{v} with a certain dose \\hat{d} . Using a constraint-based reformulation of coverage-based objectives we eliminate the trade-off between coverage and competing objectives during treatment planning. In-depth convergence tests including 324 treatment plan optimizations demonstrate the reliability of coverage-based constraints for varying levels of probability, dose and volume. General clinical applicability of coverage-based constraints is demonstrated for two cases. A sensitivity analysis regarding penalty variations within this planing study based on IMRT treatment planning using (1) coverage-based constraints, (2) coverage-based objectives, (3) probabilistic optimization, (4) robust optimization and (5) conventional margins illustrates the potential benefit of coverage-based constraints that do not require tedious adjustment of target volume objectives.
Sangiorgio, João Paulo Menck; Neves, Felipe Lucas da Silva; Rocha Dos Santos, Manuela; França-Grohmann, Isabela Lima; Casarin, Renato Corrêa Viana; Casati, Márcio Zaffalon; Santamaria, Mauro Pedrine; Sallum, Enilson Antonio
2017-12-01
Considering xenogeneic collagen matrix (CM) and enamel matrix derivative (EMD) characteristics, it is suggested that their combination could promote superior clinical outcomes in root coverage procedures. Thus, the aim of this parallel, double-masked, dual-center, randomized clinical trial is to evaluate clinical outcomes after treatment of localized gingival recession (GR) by a coronally advanced flap (CAF) combined with CM and/or EMD. Sixty-eight patients presenting one Miller Class I or II GRs were randomly assigned to receive either CAF (n = 17); CAF + CM (n = 17); CAF + EMD (n = 17), or CAF + CM + EMD (n = 17). Recession height, probing depth, clinical attachment level, and keratinized tissue width and thickness were measured at baseline and 90 days and 6 months after surgery. The obtained root coverage was 68.04% ± 24.11% for CAF; 87.20% ± 15.01% for CAF + CM; 88.77% ± 20.66% for CAF + EMD; and 91.59% ± 11.08% for CAF + CM + EMD after 6 months. Groups that received biomaterials showed greater values (P <0.05). Complete root coverage (CRC) for CAF + EMD was 70.59%, significantly superior to CAF alone (23.53%); CAF + CM (52.94%), and CAF + CM + EMD (51.47%) (P <0.05). Keratinized tissue thickness gain was significant only in CM-treated groups (P <0.05). The three approaches are superior to CAF alone for root coverage. EMD provides highest levels of CRC; however, the addition of CM increases gingival thickness. The combination approach does not seem justified.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rong, Yi, E-mail: yi.rong@osumc.edu; Chen, Yu; Lu, Weiguo
Purpose: Despite superior target dose uniformity, helical tomotherapy{sup ®} (HT) may involve a trade-off between longitudinal dose conformity and beam-on time (BOT), due to the limitation of only three available jaw sizes with the conventional HT (1.0, 2.5, and 5.0 cm). The recently introduced dynamic running-start-stop (RSS) delivery allows smaller jaw opening at the superior and inferior ends of the target when a sharp penumbra is needed. This study compared the dosimetric performance of RSS delivery with the fixed jaw HT delivery. Methods: Twenty patient cases were selected and deidentified prior to treatment planning, including 16 common clinical cases (brain,more » head and neck (HN), lung, and prostate) and four special cases of whole brain with hippocampus avoidance (WBHA) that require a high degree of dose modulation. HT plans were generated for common clinical cases using the fixed 2.5 cm jaw width (HT2.5) and WBHA cases using 1.0 cm (HT1.0). The jaw widths for RSS were preset with a larger size (RSS5.0 vs HT2.5 and RSS2.5 vs HT1.0). Both delivery techniques were planned based on identical contours, prescriptions, and planning objectives. Dose indices for targets and critical organs were compared using dose-volume histograms, BOT, and monitor units. Results: The average BOT was reduced from 4.8 min with HT2.5 to 2.5 min with RSS5.0. Target dose homogeneity with RSS5.0 was shown comparable to HT2.5 for common clinical sites. Superior normal tissue sparing was observed in RSS5.0 for optic nerves and optic chiasm in brain and HN cases. RSS5.0 demonstrated improved dose sparing for cord and esophagus in lung cases, as well as penile bulb in prostate cases. The mean body dose was comparable for both techniques. For the WBHA cases, the target homogeneity was significantly degraded in RSS2.5 without distinct dose sparing for hippocampus, compared to HT1.0. Conclusions: Compared to the fixed jaw HT delivery, RSS combined with a larger jaw width provides faster treatment delivery and improved cranial-caudal target dose conformity. The target coverage achieved by RSS with a large jaw width is comparable to the fixed jaw HT delivery for common cancer sites, but may deteriorate for cases where complex geometry is present in the middle part of the target.« less
Friesen, Valerie M; Aaron, Grant J; Myatt, Mark; Neufeld, Lynnette M
2017-05-01
Food fortification is a widely used approach to increase micronutrient intake in the diet. High coverage is essential for achieving impact. Data on coverage is limited in many countries, and tools to assess coverage of fortification programs have not been standardized. In 2013, the Global Alliance for Improved Nutrition developed the Fortification Assessment Coverage Toolkit (FACT) to carry out coverage assessments in both population-based (i.e., staple foods and/or condiments) and targeted (e.g., infant and young child) fortification programs. The toolkit was designed to generate evidence on program coverage and the use of fortified foods to provide timely and programmatically relevant information for decision making. This supplement presents results from FACT surveys that assessed the coverage of population-based and targeted food fortification programs across 14 countries. It then discusses the policy and program implications of the findings for the potential for impact and program improvement.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lu, J-Y; Huang, B-T; Zhang, W-Z
Purpose: To compare volumetric modulated arc radiotherapy (VMAT) technique with fixed-gantry intensity-modulated radiotherapy (IMRT) technique for early-stage nasopharyngeal carcinoma. Methods: CT datasets of ten patients with early-stage nasopharyngeal carcinoma were included. Dual-arc VMAT and nine-field IMRT plans were generated for each case, and were then compared in terms of planning-target-volume (PTV) coverage, conformity index (CI) and homogeneity index (HI), as well as organ-at-risk (OAR) sparing, planning time, monitor units (MUs) and delivery time. Results: Compared with the IMRT plans, the VMAT plans provided comparable HI and CI of PTVnx (PTV of primary tumor of nasopharynx), superior CI and inferior HImore » of PTVnd (PTV of lymph nodes), as well as superior CI and comparable HI of PTV60 (high-risk PTV). The VMAT plans provided better sparing of the spinal cord, oral cavity and normal tissue, but inferior sparing of the brainstem planning OAR volume (PRV), larynx and parotids, as well as comparable sparing of the spinal cord PRV, brainstem, lenses, optic nerves, optic chiasm. Moreover, the average planning time (181.6 ± 36.0 min) for the VMAT plans was 171% more than that of the IMRT plans (68.1 ± 7.6 min). The MUs of the VMAT plans (609 ± 43) were 70% lower than those of the IMRT plans (2071 ± 262), while the average delivery time (2.2 ± 0.1 min) was 66% less than that of the IMRT plans (6.6 ± 0.4 min). Conclusion: Compared with the IMRT technique, the VMAT technique can achieve similar or slightly superior target dose distribution, with no significant advantages on OAR sparing, and it can achieve significant reductions of MUs and delivery time.« less
Dinh, Jeffrey; Stoker, Joshua; Georges, Rola H; Sahoo, Narayan; Zhu, X Ronald; Rath, Smruti; Mahajan, Anita; Grosshans, David R
2013-12-17
For treatment of the entire cranium using passive scattering proton therapy (PSPT) compensators are often employed in order to reduce lens and cochlear exposure. We sought to assess the advantages and consequences of utilizing compensators for the treatment of the whole brain as a component of craniospinal radiation (CSI) with PSPT. Moreover, we evaluated the potential benefits of spot scanning beam delivery in comparison to PSPT. Planning computed tomography scans for 50 consecutive CSI patients were utilized to generate passive scattering proton therapy treatment plans with and without Lucite compensators (PSW and PSWO respectively). A subset of 10 patients was randomly chosen to generate scanning beam treatment plans for comparison. All plans were generated using an Eclipse treatment planning system and were prescribed to a dose of 36 Gy(RBE), delivered in 20 fractions, to the whole brain PTV. Plans were normalized to ensure equal whole brain target coverage. Dosimetric data was compiled and statistical analyses performed using a two-tailed Student's t-test with Bonferroni corrections to account for multiple comparisons. Whole brain target coverage was comparable between all methods. However, cribriform plate coverage was superior in PSWO plans in comparison to PSW (V95%; 92.9 ± 14 vs. 97.4 ± 5, p < 0.05). As predicted, PSWO plans had significantly higher lens exposure in comparison to PSW plans (max lens dose Gy(RBE): left; 24.8 ± 0.8 vs. 22.2 ± 0.7, p < 0.05, right; 25.2 ± 0.8 vs. 22.8 ± 0.7, p < 0.05). However, PSW plans demonstrated no significant cochlear sparing vs. PSWO (mean cochlea dose Gy(RBE): 36.4 ± 0.2 vs. 36.7 ± 0.1, p = NS). Moreover, dose homogeneity was inferior in PSW plans in comparison to PSWO plans as reflected by significant alterations in both whole brain and brainstem homogeneity index (HI) and inhomogeneity coefficient (IC). In comparison to both PSPT techniques, multi-field optimized intensity modulated (MFO-IMPT) spot scanning treatment plans displayed superior sparing of both lens and cochlea (max lens: 12.5 ± 0.6 and 12.9 ± 0.7 right and left respectively; mean cochlea 28.6 ± 0.5 and 27.4 ± 0.2), although heterogeneity within target volumes was comparable to PSW plans. For PSPT treatments, the addition of a compensator imparts little clinical advantage. In contrast, the incorporation of spot scanning technology as a component of CSI treatments, offers additional normal tissue sparing which is likely of clinical significance.
Target Coverage in Wireless Sensor Networks with Probabilistic Sensors
Shan, Anxing; Xu, Xianghua; Cheng, Zongmao
2016-01-01
Sensing coverage is a fundamental problem in wireless sensor networks (WSNs), which has attracted considerable attention. Conventional research on this topic focuses on the 0/1 coverage model, which is only a coarse approximation to the practical sensing model. In this paper, we study the target coverage problem, where the objective is to find the least number of sensor nodes in randomly-deployed WSNs based on the probabilistic sensing model. We analyze the joint detection probability of target with multiple sensors. Based on the theoretical analysis of the detection probability, we formulate the minimum ϵ-detection coverage problem. We prove that the minimum ϵ-detection coverage problem is NP-hard and present an approximation algorithm called the Probabilistic Sensor Coverage Algorithm (PSCA) with provable approximation ratios. To evaluate our design, we analyze the performance of PSCA theoretically and also perform extensive simulations to demonstrate the effectiveness of our proposed algorithm. PMID:27618902
Zha, Haihong; Cai, Yuping; Yin, Yandong; Wang, Zhuozhong; Li, Kang; Zhu, Zheng-Jiang
2018-03-20
The complexity of metabolome presents a great analytical challenge for quantitative metabolite profiling, and restricts the application of metabolomics in biomarker discovery. Targeted metabolomics using multiple-reaction monitoring (MRM) technique has excellent capability for quantitative analysis, but suffers from the limited metabolite coverage. To address this challenge, we developed a new strategy, namely, SWATHtoMRM, which utilizes the broad coverage of SWATH-MS technology to develop high-coverage targeted metabolomics method. Specifically, SWATH-MS technique was first utilized to untargeted profile one pooled biological sample and to acquire the MS 2 spectra for all metabolites. Then, SWATHtoMRM was used to extract the large-scale MRM transitions for targeted analysis with coverage as high as 1000-2000 metabolites. Then, we demonstrated the advantages of SWATHtoMRM method in quantitative analysis such as coverage, reproducibility, sensitivity, and dynamic range. Finally, we applied our SWATHtoMRM approach to discover potential metabolite biomarkers for colorectal cancer (CRC) diagnosis. A high-coverage targeted metabolomics method with 1303 metabolites in one injection was developed to profile colorectal cancer tissues from CRC patients. A total of 20 potential metabolite biomarkers were discovered and validated for CRC diagnosis. In plasma samples from CRC patients, 17 out of 20 potential biomarkers were further validated to be associated with tumor resection, which may have a great potential in assessing the prognosis of CRC patients after tumor resection. Together, the SWATHtoMRM strategy provides a new way to develop high-coverage targeted metabolomics method, and facilitates the application of targeted metabolomics in disease biomarker discovery. The SWATHtoMRM program is freely available on the Internet ( http://www.zhulab.cn/software.php ).
Optimization of Self-Directed Target Coverage in Wireless Multimedia Sensor Network
Yang, Yang; Wang, Yufei; Pi, Dechang; Wang, Ruchuan
2014-01-01
Video and image sensors in wireless multimedia sensor networks (WMSNs) have directed view and limited sensing angle. So the methods to solve target coverage problem for traditional sensor networks, which use circle sensing model, are not suitable for WMSNs. Based on the FoV (field of view) sensing model and FoV disk model proposed, how expected multimedia sensor covers the target is defined by the deflection angle between target and the sensor's current orientation and the distance between target and the sensor. Then target coverage optimization algorithms based on expected coverage value are presented for single-sensor single-target, multisensor single-target, and single-sensor multitargets problems distinguishingly. Selecting the orientation that sensor rotated to cover every target falling in the FoV disk of that sensor for candidate orientations and using genetic algorithm to multisensor multitargets problem, which has NP-complete complexity, then result in the approximated minimum subset of sensors which covers all the targets in networks. Simulation results show the algorithm's performance and the effect of number of targets on the resulting subset. PMID:25136667
Mind the gap! The mitochondrial control region and its power as a phylogenetic marker in echinoids.
Bronstein, Omri; Kroh, Andreas; Haring, Elisabeth
2018-05-30
In Metazoa, mitochondrial markers are the most commonly used targets for inferring species-level molecular phylogenies due to their extremely low rate of recombination, maternal inheritance, ease of use and fast substitution rate in comparison to nuclear DNA. The mitochondrial control region (CR) is the main non-coding area of the mitochondrial genome and contains the mitochondrial origin of replication and transcription. While sequences of the cytochrome oxidase subunit 1 (COI) and 16S rRNA genes are the prime mitochondrial markers in phylogenetic studies, the highly variable CR is typically ignored and not targeted in such analyses. However, the higher substitution rate of the CR can be harnessed to infer the phylogeny of closely related species, and the use of a non-coding region alleviates biases resulting from both directional and purifying selection. Additionally, complete mitochondrial genome assemblies utilizing next generation sequencing (NGS) data often show exceptionally low coverage at specific regions, including the CR. This can only be resolved by targeted sequencing of this region. Here we provide novel sequence data for the echinoid mitochondrial control region in over 40 species across the echinoid phylogenetic tree. We demonstrate the advantages of directly targeting the CR and adjacent tRNAs to facilitate complementing low coverage NGS data from complete mitochondrial genome assemblies. Finally, we test the performance of this region as a phylogenetic marker both in the lab and in phylogenetic analyses, and demonstrate its superior performance over the other available mitochondrial markers in echinoids. Our target region of the mitochondrial CR (1) facilitates the first thorough investigation of this region across a wide range of echinoid taxa, (2) provides a tool for complementing missing data in NGS experiments, and (3) identifies the CR as a powerful, novel marker for phylogenetic inference in echinoids due to its high variability, lack of selection, and high compatibility across the entire class, outperforming conventional mitochondrial markers.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kumar, Rachit; Wild, Aaron T.; Ziegler, Mark A.
2013-10-01
Stereotactic body radiation therapy (SBRT) achieves excellent local control for locally advanced pancreatic cancer (LAPC), but may increase late duodenal toxicity. Volumetric-modulated arc therapy (VMAT) delivers intensity-modulated radiation therapy (IMRT) with a rotating gantry rather than multiple fixed beams. This study dosimetrically evaluates the feasibility of implementing duodenal constraints for SBRT using VMAT vs IMRT. Non–duodenal sparing (NS) and duodenal-sparing (DS) VMAT and IMRT plans delivering 25 Gy in 1 fraction were generated for 15 patients with LAPC. DS plans were constrained to duodenal D{sub max} of<30 Gy at any point. VMAT used 1 360° coplanar arc with 4° spacingmore » between control points, whereas IMRT used 9 coplanar beams with fixed gantry positions at 40° angles. Dosimetric parameters for target volumes and organs at risk were compared for DS planning vs NS planning and VMAT vs IMRT using paired-sample Wilcoxon signed rank tests. Both DS VMAT and DS IMRT achieved significantly reduced duodenal D{sub mean}, D{sub max}, D{sub 1cc}, D{sub 4%}, and V{sub 20} {sub Gy} compared with NS plans (all p≤0.002). DS constraints compromised target coverage for IMRT as demonstrated by reduced V{sub 95%} (p = 0.01) and D{sub mean} (p = 0.02), but not for VMAT. DS constraints resulted in increased dose to right kidney, spinal cord, stomach, and liver for VMAT. Direct comparison of DS VMAT and DS IMRT revealed that VMAT was superior in sparing the left kidney (p<0.001) and the spinal cord (p<0.001), whereas IMRT was superior in sparing the stomach (p = 0.05) and the liver (p = 0.003). DS VMAT required 21% fewer monitor units (p<0.001) and delivered treatment 2.4 minutes faster (p<0.001) than DS IMRT. Implementing DS constraints during SBRT planning for LAPC can significantly reduce duodenal point or volumetric dose parameters for both VMAT and IMRT. The primary consequence of implementing DS constraints for VMAT is increased dose to other organs at risk, whereas for IMRT it is compromised target coverage. These findings suggest clinical situations where each technique may be most useful if DS constraints are to be employed.« less
EEG source localization: Sensor density and head surface coverage.
Song, Jasmine; Davey, Colin; Poulsen, Catherine; Luu, Phan; Turovets, Sergei; Anderson, Erik; Li, Kai; Tucker, Don
2015-12-30
The accuracy of EEG source localization depends on a sufficient sampling of the surface potential field, an accurate conducting volume estimation (head model), and a suitable and well-understood inverse technique. The goal of the present study is to examine the effect of sampling density and coverage on the ability to accurately localize sources, using common linear inverse weight techniques, at different depths. Several inverse methods are examined, using the popular head conductivity. Simulation studies were employed to examine the effect of spatial sampling of the potential field at the head surface, in terms of sensor density and coverage of the inferior and superior head regions. In addition, the effects of sensor density and coverage are investigated in the source localization of epileptiform EEG. Greater sensor density improves source localization accuracy. Moreover, across all sampling density and inverse methods, adding samples on the inferior surface improves the accuracy of source estimates at all depths. More accurate source localization of EEG data can be achieved with high spatial sampling of the head surface electrodes. The most accurate source localization is obtained when the voltage surface is densely sampled over both the superior and inferior surfaces. Copyright © 2015 The Authors. Published by Elsevier B.V. All rights reserved.
Neal, Sarah; Channon, Andrew Amos; Carter, Sarah; Falkingham, Jane
2015-06-16
The drive toward universal health coverage (UHC) is central to the post 2015 agenda, and is incorporated as a target in the new Sustainable Development Goals. However, it is recognised that an equity dimension needs to be included when progress to this goal is monitored. WHO have developed a monitoring framework which proposes a target of 80% coverage for all populations regardless of income and place of residence by 2030, and this paper examines the feasibility of this target in relation to antenatal care and skilled care at delivery. We analyse the coverage gap between the poorest and richest groups within the population for antenatal care and presence of a skilled attendant at birth for countries grouped by overall coverage of each maternal health service. Average annual rates of improvement needed for each grouping (disaggregated by wealth quintile and urban/rural residence) to reach the goal are also calculated, alongside rates of progress over the past decades for comparative purposes. Marked inequities are seen in all groups except in countries where overall coverage is high. As the monitoring framework has an absolute target countries with currently very low coverage are required to make rapid and sustained progress, in particular for the poorest and those living in rural areas. The rate of past progress will need to be accelerated markedly in most countries if the target is to be achieved, although several countries have demonstrated the rate of progress required is feasible both for the population as a whole and for the poorest. For countries with currently low coverage the target of 80% essential coverage for all populations will be challenging. Lessons should be drawn from countries who have achieved rapid and equitable progress in the past.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ashenafi, M; Koch, N; Peng, J
Purpose: We performed a comparative planning study among High Dose Rate (HDR) brachytherapy, superficial electrons, Volume Modulated Arc Therapy (VMAT), and Helical IMRT (Tomotherapy) for squamous cell carcinoma of the abdominal wall with consideration for the underlining bowel. Methods: A 69-year old female presented with squamous cell carcinoma protruding 8mm beyond the anterior skin surface of the midabdomen was considered for treatment. The patient had a ventral hernia which resulted in the reduction of the abdominal wall thickness and the adjacent small bowel being the dose limiting structure. Four plans were generated using different treatment modalities: a) an enface electronmore » field (eMC, Eclipse v. 11), b) Tomotherapy (HI-Art II v.5.0.5), c) VMAT (Acuros, Eclipse v. 11), and d) HDR using a Freiburg applicator (Oncentra v. 4.3). The following plan objectives were used for all four plans: for the CTV target, V90% ≥90% (61.8Gy2/2).For the small bowel, D0.1cc < 56.2 Gy2/2 was a hard constraint and expressed as a percentage of the prescription for comparison to demonstrate the dose fall-off achieved among the modalities.For HDR, V200% <0.1cc was an additional constraint. Multiple dosimetric parameters, including those listed above, were compared among the four modalities. Results: The HDR plan showed comparable target coverage compared to the Tomotherapy plan and better coverage compared to the electron plan. Small bowel doses (D0.1cc) were lower in HDR plan compared to Tomotherapy, electron, & VMAT plans (88.8%, 89.6%, 90.9%, & 96.6%). Integral dose to the whole body (V5%) was much higher for HDR, VMAT, and Tomotherapy when compared to electron plan by factors of seven, eight, and ten, respectively. After reviewing all treatment modalities, the physician selected HDR owing to better control of the small bowel dose while maintaining adequate target coverage. Conclusion: This case study demonstrated HDR can successfully treat superficial lesions with superior sparing of underlying structures.« less
Abraham, S; Fogliata, A; Jordaan, A; Clivio, A; Vanetti, E; Cozzi, L
2013-01-01
Objective: To evaluate the use of volumetric-modulated arc therapy [VMAT, RapidArc® (RA); Varian Medical Systems, Palo Alto, CA] for the treatment of cutaneous Kaposi’s sarcoma (KS) of lower extremities with adequate target coverage and high bone sparing, and to compare VMAT with electron beam therapy. Methods: 10 patients were planned with either RA or electron beams. The dose was prescribed to 30 Gy, 10 fractions, to mean the planning target volume (PTV), and significant maximum dose to bone was limited to 30 Gy. Plans were designed for 6-MV photon beams for RA and 6 MeV for electrons. Dose distributions were computed with AcurosXB® (Varian Medical Systems) for photons and with a Monte Carlo algorithm for electrons. Results: V90% was 97.3±1.2 for RA plans and 78.2±2.6 for electrons; similarly, V107% was 2.5±2.2 and 37.7±3.4, respectively. RA met coverage criteria. Concerning bone sparing, D2% was 29.6±1.1 for RA and 31.0±2.4 for electrons. Although acceptable for bone involvement, pronounced target coverage violations were obtained for electron plans. Monitor units were similar for electrons and RA, although for the latter they increased when superior bone sparing was imposed. Delivery times were 12.1±4.0 min for electrons and 4.8±1.3 min for the most modulated RA plans. Conclusion: High plan quality was shown for KS in the lower extremities using VMAT, and this might simplify their management in comparison with the more conventional usage of electrons, particularly in institutes with limited staff resources and heavy workloads. Advances in knowledge: VMAT is also dosimetrically extremely advantageous in a typology of treatments where electron beam therapy is mainly considered to be effective owing to the limited penetration of the beams. PMID:23392192
A Two-Phase Coverage-Enhancing Algorithm for Hybrid Wireless Sensor Networks.
Zhang, Qingguo; Fok, Mable P
2017-01-09
Providing field coverage is a key task in many sensor network applications. In certain scenarios, the sensor field may have coverage holes due to random initial deployment of sensors; thus, the desired level of coverage cannot be achieved. A hybrid wireless sensor network is a cost-effective solution to this problem, which is achieved by repositioning a portion of the mobile sensors in the network to meet the network coverage requirement. This paper investigates how to redeploy mobile sensor nodes to improve network coverage in hybrid wireless sensor networks. We propose a two-phase coverage-enhancing algorithm for hybrid wireless sensor networks. In phase one, we use a differential evolution algorithm to compute the candidate's target positions in the mobile sensor nodes that could potentially improve coverage. In the second phase, we use an optimization scheme on the candidate's target positions calculated from phase one to reduce the accumulated potential moving distance of mobile sensors, such that the exact mobile sensor nodes that need to be moved as well as their final target positions can be determined. Experimental results show that the proposed algorithm provided significant improvement in terms of area coverage rate, average moving distance, area coverage-distance rate and the number of moved mobile sensors, when compare with other approaches.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Qi, S; Kishan, A; Alexander, S
2015-06-15
Purpose: We have observed improved local control probability (LCP) for adjuvant mesothelioma radiotherapy following pleurectomy/decortication using Tomotherapy compared to the conventional 3D technique (p<0.05). This work assesses the correlation between the improved clinical outcomes against dosimetry quantities. Methods: Thirty-eight mesothelioma cases consecutively treated at our clinic were retrospectively analyzed. Sixteen patients were treated using 3D technique planned on the Eclipse for c-arm accelerators prior to 7/2012; the other 22 cases were treated on Tomotherapy using helical IMRT after 7/2012. Typical 3D plans consisting of 15 MV AP/PA photon fields prescribed to 10 cm depth followed by matching electron fields withmore » energy ranging from 8–16 MeV. Tomotherapy plans were designed using 2.5cm jaw, 0.287 pitch with directional blocking of the contralateral lung. The same prescription of 45 Gy (1.8GyX25) was used for both techniques. The dosimetry metrics for the critical structures: ipsilateral-/contralateral-lung, heart, cord, esophagus, etc were compared between two techniques. Results: Superior LCP is closely associated with improved target coverage. Tomotherapy plans yielded dramatically better target coverage and less dose heterogeneity despite of more advanced/larger disease. The averaged PTV volumes were 2287.3±569.9 (Tomotherapy) vs. 1904.8±312.3cc (3D); V100s were: 91.1±4.0 (%) vs. 47.8±12.7 (%) with heterogeneity indices of 1.20±0.1 vs.1.37±0.38 and for the Tomotherapy and 3D plans, respectively. Compared to the 3D technique, we observed significant lower maximum cord doses (p<0.001), lower mean esophagus doses (p<0.002), and lower heart mean doses when tumor was left-sided (p=0.002). For ipsilateral-/contralateral-lungs, however, the mean doses and V20, V5 of Tomotherapy plans were significantly higher than the 3D plans (p<0.01) regardless which sides of lung were treated. However, rates of radiation pneumonitis were no different. Conclusion: Tomotherapy achieved great improvement of plan quality including target coverage, resulting in significantly better local control over the traditional 3D technique for adjuvant radiotherapy for mesothelioma.« less
CBCT-guided evolutive library for cervical adaptive IMRT.
Rigaud, Bastien; Simon, Antoine; Gobeli, Maxime; Lafond, Caroline; Leseur, Julie; Barateau, Anais; Jaksic, Nicolas; Castelli, Joël; Williaume, Danièle; Haigron, Pascal; De Crevoisier, Renaud
2018-04-01
In the context of adaptive radiation therapy (ART) for locally advanced cervical carcinoma (LACC), this study proposed an original cone-beam computed tomography (CBCT)-guided "Evolutive library" and evaluated it against four other known radiotherapy (RT) strategies. For 20 patients who underwent intensity-modulated radiation therapy (IMRT) for LACC, three planning CTs [with empty (EB), intermediate (IB), and full (FB) bladder volumes], a CT scan at 20 Gy and bi-weekly CBCTs for 5 weeks were performed. Five RT strategies were simulated for each patient: "Standard RT" was based on one IB planning CT; "internal target volume (ITV)-based RT" was an ITV built from the three planning CTs; "RT with one mid-treatment replanning (MidTtReplan)" corresponded to the standard RT with a replanning at 20 Gy; "Pretreatment library ART" using a planning library based on the three planning CTs; and the "Evolutive library ART", which was the "Pretreatment library ART" strategy enriched by including some CBCT anatomies into the library when the daily clinical target volume (CTV) shape differed from the ones in the library. Two planning target volume (PTV) margins of 7 and 10 mm were evaluated. All the strategies were geometrically compared in terms of the percentage of coverage by the PTV, for the CTV and the organs at risk (OAR) delineated on the CBCT. Inadequate coverage of the CTV and OARs by the PTV was also assessed using deformable image registration. The cumulated dose distributions of each strategy were likewise estimated and compared for one patient. The "Evolutive library ART" strategy involved a number of added CBCTs: 0 for 55%; 1 for 30%; 2 for 5%; and 3 for 10% of patients. Compared with the other four, this strategy provided the highest CTV geometric coverage by the PTV, with a mean (min-max) coverage of 98.5% (96.4-100) for 10 mm margins and 96.2% (93.0-99.7) for 7 mm margins (P < 0.05). Moreover, this strategy significantly decreased the geometric coverage of the bowel. CTV undercoverage by PTV occurred in the anterior and superior uterine regions for all strategies. The dosimetric analysis at 7 mm similarly demonstrated that the "Evolutive library ART" increased the V 42.75Gy of the CTV by 27%, 20%, 13%, and 28% compared with "Standard RT", "ITV-based RT", "MidTtReplan", and "Pretreatment library ART", respectively. The dose to the bowel was also decreased by the "Evolutive library ART" compared with that by the other strategies. The "Evolutive library ART" is a personalized ART strategy that comprises a pretreatment planning library of three CT scans, enriched for half of the patients by one to three per-treatment CBCTs. This original strategy increased both the CTV coverage and bowel sparing compared with all the other tested strategies and enables us to consider a PTV margin reduction. © 2018 American Association of Physicists in Medicine.
On Efficient Deployment of Wireless Sensors for Coverage and Connectivity in Constrained 3D Space.
Wu, Chase Q; Wang, Li
2017-10-10
Sensor networks have been used in a rapidly increasing number of applications in many fields. This work generalizes a sensor deployment problem to place a minimum set of wireless sensors at candidate locations in constrained 3D space to k -cover a given set of target objects. By exhausting the combinations of discreteness/continuousness constraints on either sensor locations or target objects, we formulate four classes of sensor deployment problems in 3D space: deploy sensors at Discrete/Continuous Locations (D/CL) to cover Discrete/Continuous Targets (D/CT). We begin with the design of an approximate algorithm for DLDT and then reduce DLCT, CLDT, and CLCT to DLDT by discretizing continuous sensor locations or target objects into a set of divisions without sacrificing sensing precision. Furthermore, we consider a connected version of each problem where the deployed sensors must form a connected network, and design an approximation algorithm to minimize the number of deployed sensors with connectivity guarantee. For performance comparison, we design and implement an optimal solution and a genetic algorithm (GA)-based approach. Extensive simulation results show that the proposed deployment algorithms consistently outperform the GA-based heuristic and achieve a close-to-optimal performance in small-scale problem instances and a significantly superior overall performance than the theoretical upper bound.
Estimating the coverage of mental health programmes: a systematic review.
De Silva, Mary J; Lee, Lucy; Fuhr, Daniela C; Rathod, Sujit; Chisholm, Dan; Schellenberg, Joanna; Patel, Vikram
2014-04-01
The large treatment gap for people suffering from mental disorders has led to initiatives to scale up mental health services. In order to track progress, estimates of programme coverage, and changes in coverage over time, are needed. Systematic review of mental health programme evaluations that assess coverage, measured either as the proportion of the target population in contact with services (contact coverage) or as the proportion of the target population who receive appropriate and effective care (effective coverage). We performed a search of electronic databases and grey literature up to March 2013 and contacted experts in the field. Methods to estimate the numerator (service utilization) and the denominator (target population) were reviewed to explore methods which could be used in programme evaluations. We identified 15 735 unique records of which only seven met the inclusion criteria. All studies reported contact coverage. No study explicitly measured effective coverage, but it was possible to estimate this for one study. In six studies the numerator of coverage, service utilization, was estimated using routine clinical information, whereas one study used a national community survey. The methods for estimating the denominator, the population in need of services, were more varied and included national prevalence surveys case registers, and estimates from the literature. Very few coverage estimates are available. Coverage could be estimated at low cost by combining routine programme data with population prevalence estimates from national surveys.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Salem, Ahmed, E-mail: ahmed.salem@doctors.org.uk; Mohamad, Issa; Dayyat, Abdulmajeed
2015-10-01
Radiation pneumonitis is a well-documented side effect of radiation therapy for breast cancer. The purpose of this study was to compare combined photon-electron, photon-only, and electron-only plans in the radiation treatment of the supraclavicular lymph nodes. In total, 13 patients requiring chest wall and supraclavicular nodal irradiation were planned retrospectively using combined photon-electron, photon-only, and electron-only supraclavicular beams. A dose of 50 Gy over 25 fractions was prescribed. Chest wall irradiation parameters were fixed for all plans. The goal of this planning effort was to cover 95% of the supraclavicular clinical target volume (CTV) with 95% of the prescribed dosemore » and to minimize the volume receiving ≥ 105% of the dose. Comparative end points were supraclavicular CTV coverage (volume covered by the 95% isodose line), hotspot volume, maximum radiation dose, contralateral breast dose, mean total lung dose, total lung volume percentage receiving at least 20 Gy (V{sub 20} {sub Gy}), heart volume percentage receiving at least 25 Gy (V{sub 25} {sub Gy}). Electron and photon energies ranged from 8 to 18 MeV and 4 to 6 MV, respectively. The ratio of photon-to-electron fractions in combined beams ranged from 5:20 to 15:10. Supraclavicular nodal coverage was highest in photon-only (mean = 96.2 ± 3.5%) followed closely by combined photon-electron (mean = 94.2 ± 2.5%) and lowest in electron-only plans (mean = 81.7 ± 14.8%, p < 0.001). The volume of tissue receiving ≥ 105% of the prescription dose was higher in the electron-only (mean = 69.7 ± 56.1 cm{sup 3}) as opposed to combined photon-electron (mean = 50.8 ± 40.9 cm{sup 3}) and photon-only beams (mean = 32.2 ± 28.1 cm{sup 3}, p = 0.114). Heart V{sub 25} {sub Gy} was not statistically different among the plans (p = 0.999). Total lung V{sub 20} {sub Gy} was lowest in electron-only (mean = 10.9 ± 2.3%) followed by combined photon-electron (mean = 13.8 ± 2.3%) and highest in photon-only plans (mean = 16.2 ± 3%, p < 0.001). As expected, photon-only plans demonstrated the highest target coverage and total lung V{sub 20} {sub Gy}. The superiority of electron-only beams, in terms of decreasing lung dose, is set back by the dosimetric hotspots associated with such plans. Combined photon-electron treatment is a feasible technique for supraclavicular nodal irradiation and results in adequate target coverage, acceptable dosimetric hotspot volume, and slightly reduced lung dose.« less
Hunter, Corey W; Yang, Ajax; Davis, Tim
2017-10-01
While spinal cord stimulation (SCS) has established itself as an accepted and validated treatment for neuropathic pain, there are a number of conditions where it has experienced less, long-term success: post amputee pain (PAP) being one of them. Dorsal root ganglion (DRG) stimulation has shown great promise, particularly in conditions where traditional SCS has fallen short. One major difference between DRG stimulation and traditional SCS is the ability to provide focal stimulation over targeted areas. While this may be a contributing factor to its superiority, it can also be a limitation insofar stimulating the wrong DRG(s) can lead to failure. This is particularly relevant in conditions like PAP where neuroplastic maladaptation occurs causing the pain to deviate from expected patterns, thus creating uncertainty and variability in predicting targets for stimulation. We propose selective radiofrequency (RF) stimulation of the DRG as a method for preoperatively predicting targets for neuromodulation in patients with PAP. We present four patients with PAP of the lower extremities. RF stimulation was used to selectively stimulate individual DRG's, creating areas of paresthesias to see which most closely correlated/overlapped with the painful area(s). RF stimulation to the DRG's that resulted in the desirable paresthesia coverage in the residual or the missing limb(s) was recorded as "positive." Trial DRG leads were placed based on the positive RF stimulation findings. In each patient, stimulating one or more DRG(s) produced paresthesias patterns that were contradictory to know dermatomal patterns. Upon completion of a one-week trial all four patients reported 60-90% pain relief, with coverage over the painful areas, and opted for permanent implant. Mapping the DRG via RF stimulation appears to provide improved accuracy for determining lead placement in the setting of PAP where pain patterns are known to deviate from conventional dermatomal mapping. © 2017 International Neuromodulation Society.
Ohri, Nisha; Cordeiro, Peter G; Keam, Jennifer; Ballangrud, Ase; Shi, Weiji; Zhang, Zhigang; Nerbun, Claire T; Woch, Katherine M; Stein, Nicholas F; Zhou, Ying; McCormick, Beryl; Powell, Simon N; Ho, Alice Y
2012-10-01
To assess the impact of immediate breast reconstruction on postmastectomy radiation (PMRT) using dose-volume histogram (DVH) data. Two hundred forty-seven women underwent PMRT at our center, 196 with implant reconstruction and 51 without reconstruction. Patients with reconstruction were treated with tangential photons, and patients without reconstruction were treated with en-face electron fields and customized bolus. Twenty percent of patients received internal mammary node (IMN) treatment. The DVH data were compared between groups. Ipsilateral lung parameters included V20 (% volume receiving 20 Gy), V40 (% volume receiving 40 Gy), mean dose, and maximum dose. Heart parameters included V25 (% volume receiving 25 Gy), mean dose, and maximum dose. IMN coverage was assessed when applicable. Chest wall coverage was assessed in patients with reconstruction. Propensity-matched analysis adjusted for potential confounders of laterality and IMN treatment. Reconstruction was associated with lower lung V20, mean dose, and maximum dose compared with no reconstruction (all P<.0001). These associations persisted on propensity-matched analysis (all P<.0001). Heart doses were similar between groups (P=NS). Ninety percent of patients with reconstruction had excellent chest wall coverage (D95 >98%). IMN coverage was superior in patients with reconstruction (D95 >92.0 vs 75.7%, P<.001). IMN treatment significantly increased lung and heart parameters in patients with reconstruction (all P<.05) but minimally affected those without reconstruction (all P>.05). Among IMN-treated patients, only lower lung V20 in those without reconstruction persisted (P=.022), and mean and maximum heart doses were higher than in patients without reconstruction (P=.006, P=.015, respectively). Implant reconstruction does not compromise the technical quality of PMRT when the IMNs are untreated. Treatment technique, not reconstruction, is the primary determinant of target coverage and normal tissue doses. Published by Elsevier Inc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Syh, J; Syh, J; Patel, B
2015-06-15
Purpose: The multichannel cylindrical applicator has a distinctive modification of the traditional single channel cylindrical applicator. The novel multichannel applicator has additional peripheral channels that provide more flexibility both in treatment planning process and outcomes. To protect by reducing doses to adjacent organ at risk (OAR) while maintaining target coverage with inverse plan optimization are the goals for such novel Brachytherapy device. Through a series of comparison and analysis of reults in more than forty patients who received HDR Brachytherapy using multichannel vaginal applicator, this procedure has been implemented in our institution. Methods: Multichannel planning was CT image based. Themore » CTV of 5mm vaginal cuff rind with prescribed length was well reconstructed as well as bladder and rectum. At least D95 of CTV coverage is 95% of prescribed dose. Multichannel inverse plan optimization algorithm not only shapes target dose cloud but set dose avoids to OAR’s exclusively. The doses of D2cc, D5cc and D5; volume of V2Gy in OAR’s were selected to compare with single channel results when sole central channel is only possibility. Results: Study demonstrates plan superiorly in OAR’s doe reduction in multi-channel plan. The D2cc of the rectum and bladder were showing a little lower for multichannel vs. single channel. The V2Gy of the rectum was 93.72% vs. 83.79% (p=0.007) for single channel vs. multichannel respectively. Absolute reduced mean dose of D5 by multichannel was 17 cGy (s.d.=6.4) and 44 cGy (s.d.=15.2) in bladder and rectum respectively. Conclusion: The optimization solution in multichannel was to maintain D95 CTV coverage while reducing the dose to OAR’s. Dosimetric advantage in sparing critical organs by using a multichannel applicator in HDR Brachytherapy treatment of the vaginal cuff is so promising and has been implemented clinically.« less
Wilson, Elizabeth Ruth; Kyle, Theodore K; Nadglowski, Joseph F; Stanford, Fatima Cody
2017-02-01
Evidence-based obesity treatments, such as bariatric surgery, are not considered essential health benefits under the Affordable Care Act. Employer-sponsored wellness programs with incentives based on biometric outcomes are allowed and often used despite mixed evidence regarding their effectiveness. This study examines consumers' perceptions of their coverage for obesity treatments and exposure to workplace wellness programs. A total of 7,378 participants completed an online survey during 2015-2016. Respondents answered questions regarding their health coverage for seven medical services and exposure to employer wellness programs that target weight or body mass index (BMI). Using χ 2 tests, associations between perceptions of exposure to employer wellness programs and coverage for medical services were examined. Differences between survey years were also assessed. Most respondents reported they did not have health coverage for obesity treatments, but more of the respondents with employer wellness programs reported having coverage. Neither the perception of coverage for obesity treatments nor exposure to wellness programs increased between 2015 and 2016. Even when consumers have exposure to employer wellness programs that target BMI, their health insurance often excludes obesity treatments. Given the clinical and cost-effectiveness of such treatments, reducing that coverage gap may mitigate obesity's individual- and population-level effects. © 2017 The Obesity Society.
A Two-Phase Coverage-Enhancing Algorithm for Hybrid Wireless Sensor Networks
Zhang, Qingguo; Fok, Mable P.
2017-01-01
Providing field coverage is a key task in many sensor network applications. In certain scenarios, the sensor field may have coverage holes due to random initial deployment of sensors; thus, the desired level of coverage cannot be achieved. A hybrid wireless sensor network is a cost-effective solution to this problem, which is achieved by repositioning a portion of the mobile sensors in the network to meet the network coverage requirement. This paper investigates how to redeploy mobile sensor nodes to improve network coverage in hybrid wireless sensor networks. We propose a two-phase coverage-enhancing algorithm for hybrid wireless sensor networks. In phase one, we use a differential evolution algorithm to compute the candidate’s target positions in the mobile sensor nodes that could potentially improve coverage. In the second phase, we use an optimization scheme on the candidate’s target positions calculated from phase one to reduce the accumulated potential moving distance of mobile sensors, such that the exact mobile sensor nodes that need to be moved as well as their final target positions can be determined. Experimental results show that the proposed algorithm provided significant improvement in terms of area coverage rate, average moving distance, area coverage–distance rate and the number of moved mobile sensors, when compare with other approaches. PMID:28075365
42 CFR 436.229 - Optional targeted low-income children.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 42 Public Health 4 2011-10-01 2011-10-01 false Optional targeted low-income children. 436.229... Options for Coverage as Categorically Needy Options for Coverage of Families and Children and Aged, Blind, and Disabled Individuals, Including Pregnant Women § 436.229 Optional targeted low-income children...
42 CFR 436.229 - Optional targeted low-income children.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 42 Public Health 4 2010-10-01 2010-10-01 false Optional targeted low-income children. 436.229... Options for Coverage as Categorically Needy Options for Coverage of Families and Children and Aged, Blind, and Disabled Individuals, Including Pregnant Women § 436.229 Optional targeted low-income children...
42 CFR 436.229 - Optional targeted low-income children.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 42 Public Health 4 2013-10-01 2013-10-01 false Optional targeted low-income children. 436.229... Options for Coverage as Categorically Needy Options for Coverage of Families and Children and Aged, Blind, and Disabled Individuals, Including Pregnant Women § 436.229 Optional targeted low-income children...
42 CFR 436.229 - Optional targeted low-income children.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 42 Public Health 4 2012-10-01 2012-10-01 false Optional targeted low-income children. 436.229... Options for Coverage as Categorically Needy Options for Coverage of Families and Children and Aged, Blind, and Disabled Individuals, Including Pregnant Women § 436.229 Optional targeted low-income children...
42 CFR 436.229 - Optional targeted low-income children.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 42 Public Health 4 2014-10-01 2014-10-01 false Optional targeted low-income children. 436.229... Options for Coverage as Categorically Needy Options for Coverage of Families and Children and Aged, Blind, and Disabled Individuals, Including Pregnant Women § 436.229 Optional targeted low-income children...
Li, Ming; Miao, Chunyan; Leung, Cyril
2015-01-01
Coverage control is one of the most fundamental issues in directional sensor networks. In this paper, the coverage optimization problem in a directional sensor network is formulated as a multi-objective optimization problem. It takes into account the coverage rate of the network, the number of working sensor nodes and the connectivity of the network. The coverage problem considered in this paper is characterized by the geographical irregularity of the sensed events and heterogeneity of the sensor nodes in terms of sensing radius, field of angle and communication radius. To solve this multi-objective problem, we introduce a learning automata-based coral reef algorithm for adaptive parameter selection and use a novel Tchebycheff decomposition method to decompose the multi-objective problem into a single-objective problem. Simulation results show the consistent superiority of the proposed algorithm over alternative approaches. PMID:26690162
Li, Ming; Miao, Chunyan; Leung, Cyril
2015-12-04
Coverage control is one of the most fundamental issues in directional sensor networks. In this paper, the coverage optimization problem in a directional sensor network is formulated as a multi-objective optimization problem. It takes into account the coverage rate of the network, the number of working sensor nodes and the connectivity of the network. The coverage problem considered in this paper is characterized by the geographical irregularity of the sensed events and heterogeneity of the sensor nodes in terms of sensing radius, field of angle and communication radius. To solve this multi-objective problem, we introduce a learning automata-based coral reef algorithm for adaptive parameter selection and use a novel Tchebycheff decomposition method to decompose the multi-objective problem into a single-objective problem. Simulation results show the consistent superiority of the proposed algorithm over alternative approaches.
Assessment of PlanIQ Feasibility DVH for head and neck treatment planning.
Fried, David V; Chera, Bhishamjit S; Das, Shiva K
2017-09-01
Designing a radiation plan that optimally delivers both target coverage and normal tissue sparing is challenging. There are limited tools to determine what is dosimetrically achievable and frequently the experience of the planner/physician is relied upon to make these determinations. PlanIQ software provides a tool that uses target and organ at risk (OAR) geometry to indicate the difficulty of achieving different points for organ dose-volume histograms (DVH). We hypothesized that PlanIQ Feasibility DVH may aid planners in reducing dose to OARs. Clinically delivered head and neck treatments (clinical plan) were re-planned (re-plan) putting high emphasis on maximally sparing the contralateral parotid gland, contralateral submandibular gland, and larynx while maintaining routine clinical dosimetric objectives. The planner was blinded to the results of the clinically delivered plan as well as the Feasibility DVHs from PlanIQ. The re-plan treatments were designed using 3-arc VMAT in Raystation (RaySearch Laboratories, Sweden). The planner was then given the results from the PlanIQ Feasibility DVH analysis and developed an additional plan incorporating this information using 4-arc VMAT (IQ plan). The DVHs across the three treatment plans were compared with what was deemed "impossible" by PlanIQ's Feasibility DVH (Impossible DVH). The impossible DVH (red) is defined as the DVH generated using the minimal dose that any voxel outside the targets must receive given 100% target coverage. The re-plans performed blinded to PlanIQ Feasibilty DVH achieved superior sparing of aforementioned OARs compared to the clinically delivered plans and resulted in discrepancies from the impossible DVHs by an average of 200-700 cGy. Using the PlanIQ Feasibility DVH led to additionalOAR sparing compared to both the re-plans and clinical plans and reduced the discrepancies from the impossible DVHs to an average of approximately 100 cGy. The dose reduction from clinical to re-plan and re-plan to IQ plan were significantly different even when taking into account multiple hypothesis testing for both the contralateral parotid and the larynx (P < 0.004 for all comparisons). No significant differences were observed between the three plans for the contralateral parotid when considering multiple hypothesis testing. Clinical treatment plans and blinded re-plans were found to suboptimally spare OARs. PlanIQ could aid planners in generating treatment plans that push the limits of OAR sparing while maintaining routine clinical target coverage goals. © 2017 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Góra, Joanna, E-mail: joanna.gora@akhwien.at; EBG MedAustron GmbH, Wiener Neustadt; Stock, Markus
Purpose: To investigate robust margin strategies in intensity modulated proton therapy to account for interfractional organ motion in prostate cancer. Methods and Materials: For 9 patients, one planning computed tomography (CT) scan and daily and weekly cone beam CTs (CBCTs) were acquired and coregistered. The following planning target volume (PTV) approaches were investigated: a clinical target volume (CTV) delineated on the planning CT (CTV{sub ct}) plus 10-mm margin (PTV{sub 10mm}); a reduced PTV (PTV{sub Red}): CTV{sub ct} plus 5 mm in the left-right (LR) and anterior-posterior (AP) directions and 8 mm in the inferior-superior (IS) directions; and a PTV{sub Hull}more » method: the sum of CTV{sub ct} and CTVs from 5 CBCTs from the first week plus 3 mm in the LR and IS directions and 5 mm in the AP direction. For each approach, separate plans were calculated using a spot-scanning technique with 2 lateral fields. Results: Each approach achieved excellent target coverage. Differences were observed in volume receiving 98% of the prescribed dose (V{sub 98%}) where PTV{sub Hull} and PTV{sub Red} results were superior to the PTV{sub 10mm} concept. The PTV{sub Hull} approach was more robust to organ motion. The V{sub 98%} for CTVs was 99.7%, whereas for PTV{sub Red} and PTV{sub 10mm} plans, V{sub 98%} was 98% and 96.1%, respectively. Doses to organs at risk were higher for PTV{sub Hull} and PTV{sub 10mm} plans than for PTV{sub Red}, but only differences between PTV{sub 10mm} and PTV{sub Red} were significant. Conclusions: In terms of organ sparing, the PTV{sub 10mm} method was inferior but not significantly different from the PTV{sub Red} and PTV{sub Hull} approaches. PTV{sub Hull} was most insensitive to target motion.« less
Estimating the coverage of mental health programmes: a systematic review
De Silva, Mary J; Lee, Lucy; Fuhr, Daniela C; Rathod, Sujit; Chisholm, Dan; Schellenberg, Joanna; Patel, Vikram
2014-01-01
Background The large treatment gap for people suffering from mental disorders has led to initiatives to scale up mental health services. In order to track progress, estimates of programme coverage, and changes in coverage over time, are needed. Methods Systematic review of mental health programme evaluations that assess coverage, measured either as the proportion of the target population in contact with services (contact coverage) or as the proportion of the target population who receive appropriate and effective care (effective coverage). We performed a search of electronic databases and grey literature up to March 2013 and contacted experts in the field. Methods to estimate the numerator (service utilization) and the denominator (target population) were reviewed to explore methods which could be used in programme evaluations. Results We identified 15 735 unique records of which only seven met the inclusion criteria. All studies reported contact coverage. No study explicitly measured effective coverage, but it was possible to estimate this for one study. In six studies the numerator of coverage, service utilization, was estimated using routine clinical information, whereas one study used a national community survey. The methods for estimating the denominator, the population in need of services, were more varied and included national prevalence surveys case registers, and estimates from the literature. Conclusions Very few coverage estimates are available. Coverage could be estimated at low cost by combining routine programme data with population prevalence estimates from national surveys. PMID:24760874
Measuring populations to improve vaccination coverage
NASA Astrophysics Data System (ADS)
Bharti, Nita; Djibo, Ali; Tatem, Andrew J.; Grenfell, Bryan T.; Ferrari, Matthew J.
2016-10-01
In low-income settings, vaccination campaigns supplement routine immunization but often fail to achieve coverage goals due to uncertainty about target population size and distribution. Accurate, updated estimates of target populations are rare but critical; short-term fluctuations can greatly impact population size and susceptibility. We use satellite imagery to quantify population fluctuations and the coverage achieved by a measles outbreak response vaccination campaign in urban Niger and compare campaign estimates to measurements from a post-campaign survey. Vaccine coverage was overestimated because the campaign underestimated resident numbers and seasonal migration further increased the target population. We combine satellite-derived measurements of fluctuations in population distribution with high-resolution measles case reports to develop a dynamic model that illustrates the potential improvement in vaccination campaign coverage if planners account for predictable population fluctuations. Satellite imagery can improve retrospective estimates of vaccination campaign impact and future campaign planning by synchronizing interventions with predictable population fluxes.
Measuring populations to improve vaccination coverage
Bharti, Nita; Djibo, Ali; Tatem, Andrew J.; Grenfell, Bryan T.; Ferrari, Matthew J.
2016-01-01
In low-income settings, vaccination campaigns supplement routine immunization but often fail to achieve coverage goals due to uncertainty about target population size and distribution. Accurate, updated estimates of target populations are rare but critical; short-term fluctuations can greatly impact population size and susceptibility. We use satellite imagery to quantify population fluctuations and the coverage achieved by a measles outbreak response vaccination campaign in urban Niger and compare campaign estimates to measurements from a post-campaign survey. Vaccine coverage was overestimated because the campaign underestimated resident numbers and seasonal migration further increased the target population. We combine satellite-derived measurements of fluctuations in population distribution with high-resolution measles case reports to develop a dynamic model that illustrates the potential improvement in vaccination campaign coverage if planners account for predictable population fluctuations. Satellite imagery can improve retrospective estimates of vaccination campaign impact and future campaign planning by synchronizing interventions with predictable population fluxes. PMID:27703191
77 FR 31814 - National Flood Insurance Program (NFIP); Insurance Coverage and Rates
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-30
... structures (target repetitive loss buildings) insured under the NFIP. The Notice of Proposed Rulemaking (NPRM) defined target repetitive loss buildings as those with four or more losses, or with two or more flood... flood insurance coverage to a target repetitive loss building, if an owner declined an offer of...
Pezzoli, Lorenzo; Conteh, Ishata; Kamara, Wogba; Gacic-Dobo, Marta; Ronveaux, Olivier; Perea, William A; Lewis, Rosamund F
2012-06-07
In November 2009, Sierra Leone conducted a preventive yellow fever (YF) vaccination campaign targeting individuals aged nine months and older in six health districts. The campaign was integrated with a measles follow-up campaign throughout the country targeting children aged 9-59 months. For both campaigns, the operational objective was to reach 95% of the target population. During the campaign, we used clustered lot quality assurance sampling (C-LQAS) to identify areas of low coverage to recommend timely mop-up actions. We divided the country in 20 non-overlapping lots. Twelve lots were targeted by both vaccinations, while eight only by measles. In each lot, five clusters of ten eligible individuals were selected for each vaccine. The upper threshold (UT) was set at 90% and the lower threshold (LT) at 75%. A lot was rejected for low vaccination coverage if more than 7 unvaccinated individuals (not presenting vaccination card) were found. After the campaign, we plotted the C-LQAS results against the post-campaign coverage estimations to assess if early interventions were successful enough to increase coverage in the lots that were at the level of rejection before the end of the campaign. During the last two days of campaign, based on card-confirmed vaccination status, five lots out of 20 (25.0%) failed for having low measles vaccination coverage and three lots out of 12 (25.0%) for low YF coverage. In one district, estimated post-campaign vaccination coverage for both vaccines was still not significantly above the minimum acceptable level (LT = 75%) even after vaccination mop-up activities. C-LQAS during the vaccination campaign was informative to identify areas requiring mop-up activities to reach the coverage target prior to leaving the region. The only district where mop-up activities seemed to be unsuccessful might have had logistical difficulties that should be further investigated and resolved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Reddy, Abhinav V.; Christodouleas, John P.; Wu, Tianming
Purpose: International consensus (IC) clinical target volumes (CTVs) have been proposed to standardize radiation field design in the treatment of patients at high risk of locoregional failure (LRF) after radical cystectomy. The purpose of this study was to externally validate the IC CTVs in a cohort of postsurgical patients followed up for LRF and identify revisions that might improve the IC CTVs' performance. Methods and Materials: Among 334 patients with pT3 to pT4 bladder cancer treated with radical cystectomy, LRF developed in 58 (17%), of whom 52 had computed tomography scans available for review. Images with LRF were exported intomore » a treatment planning system, and IC CTVs were contoured and evaluated for adequacy of coverage of each LRF with respect to both the patient and each of 6 pelvic subsites: common iliac (CI) region, obturator region (OR), external and internal iliac region, presacral region, cystectomy bed, or other pelvic site. Revisions to the IC contours were proposed based on the findings. Results: Of the 52 patients with documented LRF, 13 (25%) had LRFs that were outside of the IC CTV involving 17 pelvic subsites: 5 near the CI CTV, 5 near the OR CTV, 1 near the external and internal iliac region, and 6 near the cystectomy bed. The 5 CI failures were located superior to the CTV, and the 5 OR failures were located medial to the CTV. Increasing the superior boundary of the CI to a vessel-based definition of the aortic bifurcation, as well as increasing the medial extension of the OR by an additional 9 mm, decreased the number of patients with LRF outside of the IC CTV to 7 (13%). Conclusions: Modified IC CTVs inclusive of a slight adjustment superiorly for the CI region and medially for the OR may reduce the risk of pelvic failure in patients treated with adjuvant radiation therapy.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hadsell, M; Xing, L; Bush, K
We propose a new type of treatment that employs a modulated tangential photon field to provide superior coverage of complex superficial targets when compared to other commonly employed methods, and drastically reduce dose to the underlying sensitive structures often present in these cases. TMAT plans were formulated for a set of four representative cases: 1. Scalp sarcoma, 2. Posterior chest-wall sarcoma, 3. Pleural mesothelioma with intact lung, 4. Chest-wall with deep inframammary nodes. For these cases, asymmetric jaw placement, angular limitations, and central isocenter placements were used to force optimization solutions with beam lines tangential to the body surface. Whenmore » compared with unrestricted modulated arcs, the tangential arc scalp treatment reduced the max and mean doses delivered to the brain by 33Gy (from 55Gy to 22Gy) and 6Gy (from 14Gy to 8Gy), respectively. In the posterior chest wall case, the V10 for the ipsilateral lung was kept below 5% impressively while retaining the 45Gy target prescription coverage by over 97%. For the breast chest-wall case, the TMAT plan achieved reductions in high dose to the ipsilateral lung and heart by a factor of 2–3 when compared to classic, laterally opposed, tangents and reduced the V5 by 40% when compared to standard modulated arcs. TMAT has outperformed the conventional modalities of treatment for superficial lesions used in our clinic. We hope that with the advent of digitally controlled linear accelerators, we can uncover further benefits of this new technique and extend its applicability to a wider section of the patient population.« less
Pezzoli, Lorenzo; Andrews, Nick; Ronveaux, Olivier
2010-05-01
Vaccination programmes targeting disease elimination aim to achieve very high coverage levels (e.g. 95%). We calculated the precision of different clustered lot quality assurance sampling (LQAS) designs in computer-simulated surveys to provide local health officers in the field with preset LQAS plans to simply and rapidly assess programmes with high coverage targets. We calculated sample size (N), decision value (d) and misclassification errors (alpha and beta) of several LQAS plans by running 10 000 simulations. We kept the upper coverage threshold (UT) at 90% or 95% and decreased the lower threshold (LT) progressively by 5%. We measured the proportion of simulations with < or =d individuals unvaccinated or lower if the coverage was set at the UT (pUT) to calculate beta (1-pUT) and the proportion of simulations with >d unvaccinated individuals if the coverage was LT% (pLT) to calculate alpha (1-pLT). We divided N in clusters (between 5 and 10) and recalculated the errors hypothesising that the coverage would vary in the clusters according to a binomial distribution with preset standard deviations of 0.05 and 0.1 from the mean lot coverage. We selected the plans fulfilling these criteria: alpha < or = 5% beta < or = 20% in the unclustered design; alpha < or = 10% beta < or = 25% when the lots were divided in five clusters. When the interval between UT and LT was larger than 10% (e.g. 15%), we were able to select precise LQAS plans dividing the lot in five clusters with N = 50 (5 x 10) and d = 4 to evaluate programmes with 95% coverage target and d = 7 to evaluate programmes with 90% target. These plans will considerably increase the feasibility and the rapidity of conducting the LQAS in the field.
Robust optimization in lung treatment plans accounting for geometric uncertainty.
Zhang, Xin; Rong, Yi; Morrill, Steven; Fang, Jian; Narayanasamy, Ganesh; Galhardo, Edvaldo; Maraboyina, Sanjay; Croft, Christopher; Xia, Fen; Penagaricano, Jose
2018-05-01
Robust optimization generates scenario-based plans by a minimax optimization method to find optimal scenario for the trade-off between target coverage robustness and organ-at-risk (OAR) sparing. In this study, 20 lung cancer patients with tumors located at various anatomical regions within the lungs were selected and robust optimization photon treatment plans including intensity modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT) plans were generated. The plan robustness was analyzed using perturbed doses with setup error boundary of ±3 mm in anterior/posterior (AP), ±3 mm in left/right (LR), and ±5 mm in inferior/superior (IS) directions from isocenter. Perturbed doses for D 99 , D 98 , and D 95 were computed from six shifted isocenter plans to evaluate plan robustness. Dosimetric study was performed to compare the internal target volume-based robust optimization plans (ITV-IMRT and ITV-VMAT) and conventional PTV margin-based plans (PTV-IMRT and PTV-VMAT). The dosimetric comparison parameters were: ITV target mean dose (D mean ), R 95 (D 95 /D prescription ), Paddick's conformity index (CI), homogeneity index (HI), monitor unit (MU), and OAR doses including lung (D mean , V 20 Gy and V 15 Gy ), chest wall, heart, esophagus, and maximum cord doses. A comparison of optimization results showed the robust optimization plan had better ITV dose coverage, better CI, worse HI, and lower OAR doses than conventional PTV margin-based plans. Plan robustness evaluation showed that the perturbed doses of D 99 , D 98 , and D 95 were all satisfied at least 99% of the ITV to received 95% of prescription doses. It was also observed that PTV margin-based plans had higher MU than robust optimization plans. The results also showed robust optimization can generate plans that offer increased OAR sparing, especially for normal lungs and OARs near or abutting the target. Weak correlation was found between normal lung dose and target size, and no other correlation was observed in this study. © 2018 University of Arkansas for Medical Sciences. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.
Piot, Bram; Navin, Deepa; Krishnan, Nattu; Bhardwaj, Ashish; Sharma, Vivek; Marjara, Pritpal
2010-01-01
Objectives This study reports on the results of a large-scale targeted condom social marketing campaign in and around areas where female sex workers are present. The paper also describes the method that was used for the routine monitoring of condom availability in these sites. Methods The lot quality assurance sampling (LQAS) method was used for the assessment of the geographical coverage and quality of coverage of condoms in target areas in four states and along selected national highways in India, as part of Avahan, the India AIDS initiative. Results A significant general increase in condom availability was observed in the intervention area between 2005 and 2008. High coverage rates were gradually achieved through an extensive network of pharmacies and particularly of non-traditional outlets, whereas traditional outlets were instrumental in providing large volumes of condoms. Conclusion LQAS is seen as a valuable tool for the routine monitoring of the geographical coverage and of the quality of delivery systems of condoms and of health products and services in general. With a relatively small sample size, easy data collection procedures and simple analytical methods, it was possible to inform decision-makers regularly on progress towards coverage targets. PMID:20167732
Piot, Bram; Mukherjee, Amajit; Navin, Deepa; Krishnan, Nattu; Bhardwaj, Ashish; Sharma, Vivek; Marjara, Pritpal
2010-02-01
This study reports on the results of a large-scale targeted condom social marketing campaign in and around areas where female sex workers are present. The paper also describes the method that was used for the routine monitoring of condom availability in these sites. The lot quality assurance sampling (LQAS) method was used for the assessment of the geographical coverage and quality of coverage of condoms in target areas in four states and along selected national highways in India, as part of Avahan, the India AIDS initiative. A significant general increase in condom availability was observed in the intervention area between 2005 and 2008. High coverage rates were gradually achieved through an extensive network of pharmacies and particularly of non-traditional outlets, whereas traditional outlets were instrumental in providing large volumes of condoms. LQAS is seen as a valuable tool for the routine monitoring of the geographical coverage and of the quality of delivery systems of condoms and of health products and services in general. With a relatively small sample size, easy data collection procedures and simple analytical methods, it was possible to inform decision-makers regularly on progress towards coverage targets.
Trosman, Julia R; Weldon, Christine B; Kelley, R Kate; Phillips, Kathryn A
2015-03-01
Next-generation tumor sequencing (NGTS) panels, which include multiple established and novel targets across cancers, are emerging in oncology practice, but lack formal positive coverage by US payers. Lack of coverage may impact access and adoption. This study identified challenges of NGTS coverage by private payers. We conducted semi-structured interviews with 14 NGTS experts on potential NGTS benefits, and with 10 major payers, representing more than 125,000,000 enrollees, on NGTS coverage considerations. We used the framework approach of qualitative research for study design and thematic analyses and simple frequencies to further describe findings. All interviewed payers see potential NGTS benefits, but all noted challenges to formal coverage: 80% state that inherent features of NGTS do not fit the medical necessity definition required for coverage, 70% view NGTS as a bundle of targets versus comprehensive tumor characterization and may evaluate each target individually, and 70% express skepticism regarding new evidence methods proposed for NGTS. Fifty percent of payers expressed sufficient concerns about NGTS adoption and implementation that will preclude their ability to issue positive coverage policies. Payers perceive that NGTS holds significant promise but, in its current form, poses disruptive challenges to coverage policy frameworks. Proactive multidisciplinary efforts to define the direction for NGTS development, evidence generation, and incorporation into coverage policy are necessary to realize its promise and provide patient access. This study contributes to current literature, as possibly the first study to directly interview US payers on NGTS coverage and reimbursement. Copyright © 2015 by the National Comprehensive Cancer Network.
Trosman, Julia R.; Weldon, Christine B.; Kate Kelley, R.; Phillips, Kathryn A.
2015-01-01
Background Next-generation tumor sequencing (NGTS) panels, which include multiple established and novel targets across cancers, are emerging in oncology practice, but lack formal positive coverage by US payers. Lack of coverage may impact access and adoption. This study identified challenges of NGTS coverage by private payers. Methods We conducted semi-structured interviews with 14 NGTS experts on potential NGTS benefits, and with 10 major payers, representing more than 125,000,000 enrollees, on NGTS coverage considerations. We used the framework approach of qualitative research for study design and thematic analyses and simple frequencies to further describe findings. Results All interviewed payers see potential NGTS benefits, but all noted challenges to formal coverage: 80% state that inherent features of NGTS do not fit the medical necessity definition required for coverage, 70% view NGTS as a bundle of targets versus comprehensive tumor characterization and may evaluate each target individually, and 70% express skepticism regarding new evidence methods proposed for NGTS. Fifty percent of payers expressed sufficient concerns about NGTS adoption and implementation that will preclude their ability to issue positive coverage policies. Conclusions Payers perceive that NGTS holds significant promise but, in its current form, poses disruptive challenges to coverage policy frameworks. Proactive multidisciplinary efforts to define the direction for NGTS development, evidence generation, and incorporation into coverage policy are necessary to realize its promise and provide patient access. This study contributes to current literature, as possibly the first study to directly interview US payers on NGTS coverage and reimbursement. PMID:25736008
Schiffmann, L M; Brunold, M; Liwschitz, M; Goede, V; Loges, S; Wroblewski, M; Quaas, A; Alakus, H; Stippel, D; Bruns, C J; Hallek, M; Kashkar, H; Hacker, U T; Coutelle, O
2017-02-28
Vascular endothelial growth factor (VEGF)-targeting drugs normalise the tumour vasculature and improve access for chemotherapy. However, excessive VEGF inhibition fails to improve clinical outcome, and successive treatment cycles lead to incremental extracellular matrix (ECM) deposition, which limits perfusion and drug delivery. We show here, that low-dose VEGF inhibition augmented with PDGF-R inhibition leads to superior vascular normalisation without incremental ECM deposition thus maintaining access for therapy. Collagen IV expression was analysed in response to VEGF inhibition in liver metastasis of colorectal cancer (CRC) patients, in syngeneic (Panc02) and xenograft tumours of human colorectal cancer cells (LS174T). The xenograft tumours were treated with low (0.5 mg kg -1 body weight) or high (5 mg kg -1 body weight) doses of the anti-VEGF antibody bevacizumab with or without the tyrosine kinase inhibitor imatinib. Changes in tumour growth, and vascular parameters, including microvessel density, pericyte coverage, leakiness, hypoxia, perfusion, fraction of vessels with an open lumen, and type IV collagen deposition were compared. ECM deposition was increased after standard VEGF inhibition in patients and tumour models. In contrast, treatment with low-dose bevacizumab and imatinib produced similar growth inhibition without inducing detrimental collagen IV deposition, leading to superior vascular normalisation, reduced leakiness, improved oxygenation, more open vessels that permit perfusion and access for therapy. Low-dose bevacizumab augmented by imatinib selects a mature, highly normalised and well perfused tumour vasculature without inducing incremental ECM deposition that normally limits the effectiveness of VEGF targeting drugs.
Acoustic Sensor Planning for Gunshot Location in National Parks: A Pareto Front Approach
González-Castaño, Francisco Javier; Alonso, Javier Vales; Costa-Montenegro, Enrique; López-Matencio, Pablo; Vicente-Carrasco, Francisco; Parrado-García, Francisco J.; Gil-Castiñeira, Felipe; Costas-Rodríguez, Sergio
2009-01-01
In this paper, we propose a solution for gunshot location in national parks. In Spain there are agencies such as SEPRONA that fight against poaching with considerable success. The DiANa project, which is endorsed by Cabaneros National Park and the SEPRONA service, proposes a system to automatically detect and locate gunshots. This work presents its technical aspects related to network design and planning. The system consists of a network of acoustic sensors that locate gunshots by hyperbolic multi-lateration estimation. The differences in sound time arrivals allow the computation of a low error estimator of gunshot location. The accuracy of this method depends on tight sensor clock synchronization, which an ad-hoc time synchronization protocol provides. On the other hand, since the areas under surveillance are wide, and electric power is scarce, it is necessary to maximize detection coverage and minimize system cost at the same time. Therefore, sensor network planning has two targets, i.e., coverage and cost. We model planning as an unconstrained problem with two objective functions. We determine a set of candidate solutions of interest by combining a derivative-free descent method we have recently proposed with a Pareto front approach. The results are clearly superior to random seeding in a realistic simulation scenario. PMID:22303135
Acoustic sensor planning for gunshot location in national parks: a pareto front approach.
González-Castaño, Francisco Javier; Alonso, Javier Vales; Costa-Montenegro, Enrique; López-Matencio, Pablo; Vicente-Carrasco, Francisco; Parrado-García, Francisco J; Gil-Castiñeira, Felipe; Costas-Rodríguez, Sergio
2009-01-01
In this paper, we propose a solution for gunshot location in national parks. In Spain there are agencies such as SEPRONA that fight against poaching with considerable success. The DiANa project, which is endorsed by Cabaneros National Park and the SEPRONA service, proposes a system to automatically detect and locate gunshots. This work presents its technical aspects related to network design and planning. The system consists of a network of acoustic sensors that locate gunshots by hyperbolic multi-lateration estimation. The differences in sound time arrivals allow the computation of a low error estimator of gunshot location. The accuracy of this method depends on tight sensor clock synchronization, which an ad-hoc time synchronization protocol provides. On the other hand, since the areas under surveillance are wide, and electric power is scarce, it is necessary to maximize detection coverage and minimize system cost at the same time. Therefore, sensor network planning has two targets, i.e., coverage and cost. We model planning as an unconstrained problem with two objective functions. We determine a set of candidate solutions of interest by combining a derivative-free descent method we have recently proposed with a Pareto front approach. The results are clearly superior to random seeding in a realistic simulation scenario.
Paluska, Petr; Hanus, Josef; Sefrova, Jana; Rouskova, Lucie; Grepl, Jakub; Jansa, Jan; Kasaova, Linda; Hodek, Miroslav; Zouhar, Milan; Vosmik, Milan; Petera, Jiri
2012-01-01
To assess target volume coverage during prostate image-guided radiotherapy based on bony anatomy alignment and to assess possibility of safety margin reduction. Implementation of IGRT should influence safety margins. Utilization of cone-beam CT provides current 3D anatomic information directly in irradiation position. Such information enables reconstruction of the actual dose distribution. Seventeen prostate patients were treated with daily bony anatomy image-guidance. Cone-beam CT (CBCT) scans were acquired once a week immediately after bony anatomy alignment. After the prostate, seminal vesicles, rectum and bladder were contoured, the delivered dose distribution was reconstructed. Target dose coverage was evaluated by the proportion of the CTV encompassed by the 95% isodose. Original plans employed a 1 cm safety margin. Alternative plans assuming a smaller 7 mm margin between CTV and PTV were evaluated in the same way. Rectal and bladder volumes were compared with the initial ones. Rectal and bladder volumes irradiated with doses higher than 75 Gy, 70 Gy, 60 Gy, 50 Gy and 40 Gy were analyzed. In 12% of reconstructed plans the prostate coverage was not sufficient. The prostate underdosage was observed in 5 patients. Coverage of seminal vesicles was not satisfactory in 3% of plans. Most of the target underdosage corresponded to excessive rectal or bladder filling. Evaluation of alternative plans assuming a smaller 7 mm margin revealed 22% and 11% of plans where prostate and seminal vesicles coverage, respectively, was compromised. These were distributed over 8 and 7 patients, respectively. Sufficient dose coverage of target volumes was not achieved for all patients. Reducing of safety margin is not acceptable. Initial rectal and bladder volumes cannot be considered representative for subsequent treatment.
Latsuzbaia, Ardashel; Arbyn, Marc; Weyers, Steven; Mossong, Joël
2018-04-25
In Luxembourg, a national Human Papillomavirus (HPV) vaccination programme was introduced in 2008, targeting 12-17 year old girls offering a choice of bivalent or quadrivalent vaccine free of charge. In 2015, the programme was changed offering the bivalent vaccine only to 11-13 year old girls. The aim of this study was to evaluate the HPV vaccination coverage, to assess the impact of age target changes and compare vaccination coverage to other European countries. Anonymous HPV vaccination records consisting of individual vaccine doses obtained free of charge in pharmacies between 2008 and 2016 were extracted from the Luxembourgish Social Security database. Additional aggregate tables by nationality and municipality were analysed. Of the target cohort of 39,610 girls born between 1991 and 2003 residing in Luxembourg, 24,550 (62.0%) subjects obtained at least one dose, 22,082 (55.7%) obtained at least two doses, and 17,197 (43.4%) obtained three doses of HPV vaccine. The mean age at first dose was 13.7 years during 2008-14 and 12.7 years in 2016 after the age target change. Coverage varied significantly by nationality (p < 0.0001): Portuguese (80%), former Yugoslavs (74%), Luxembourgish (54%), Belgian (52%), German (47%), French (39%) and other nationalities (51%). Coverage varied also by geographical region, with lower rates (<50%) noted in some Northern and Central areas of Luxembourg (range: 38% to 78%). Overall HPV vaccination coverage in Luxembourg is moderate and varied by nationality and region. The policy changes in 2015 did not have a substantial impact except lowering age at initiating vaccination. Options to improve coverage deserve further investigation. Copyright © 2018 The Author(s). Published by Elsevier Ltd.. All rights reserved.
Abbas, Ahmar S; Moseley, Douglas; Kassam, Zahra; Kim, Sun Mo; Cho, Charles
2013-05-06
Recently, volumetric-modulated arc therapy (VMAT) has demonstrated the ability to deliver radiation dose precisely and accurately with a shorter delivery time compared to conventional intensity-modulated fixed-field treatment (IMRT). We applied the hypothesis of VMAT technique for the treatment of thoracic esophageal carcinoma to determine superior or equivalent conformal dose coverage for a large thoracic esophageal planning target volume (PTV) with superior or equivalent sparing of organs-at-risk (OARs) doses, and reduce delivery time and monitor units (MUs), in comparison with conventional fixed-field IMRT plans. We also analyzed and compared some other important metrics of treatment planning and treatment delivery for both IMRT and VMAT techniques. These metrics include: 1) the integral dose and the volume receiving intermediate dose levels between IMRT and VMATI plans; 2) the use of 4D CT to determine the internal motion margin; and 3) evaluating the dosimetry of every plan through patient-specific QA. These factors may impact the overall treatment plan quality and outcomes from the individual planning technique used. In this study, we also examined the significance of using two arcs vs. a single-arc VMAT technique for PTV coverage, OARs doses, monitor units and delivery time. Thirteen patients, stage T2-T3 N0-N1 (TNM AJCC 7th edn.), PTV volume median 395 cc (range 281-601 cc), median age 69 years (range 53 to 85), were treated from July 2010 to June 2011 with a four-field (n = 4) or five-field (n = 9) step-and-shoot IMRT technique using a 6 MV beam to a prescribed dose of 50 Gy in 20 to 25 F. These patients were retrospectively replanned using single arc (VMATI, 91 control points) and two arcs (VMATII, 182 control points). All treatment plans of the 13 study cases were evaluated using various dose-volume metrics. These included PTV D99, PTV D95, PTV V9547.5Gy(95%), PTV mean dose, Dmax, PTV dose conformity (Van't Riet conformation number (CN)), mean lung dose, lung V20 and V5, liver V30, and Dmax to the spinal canal prv3mm. Also examined were the total plan monitor units (MUs) and the beam delivery time. Equivalent target coverage was observed with both VMAT single and two-arc plans. The comparison of VMATI with fixed-field IMRT demonstrated equivalent target coverage; statistically no significant difference were found in PTV D99 (p = 0.47), PTV mean (p = 0.12), PTV D95 and PTV V9547.5Gy (95%) (p = 0.38). However, Dmax in VMATI plans was significantly lower compared to IMRT (p = 0.02). The Van't Riet dose conformation number (CN) was also statistically in favor of VMATI plans (p = 0.04). VMATI achieved lower lung V20 (p = 0.05), whereas lung V5 (p = 0.35) and mean lung dose (p = 0.62) were not significantly different. The other OARs, including spinal canal, liver, heart, and kidneys showed no statistically significant differences between the two techniques. Treatment time delivery for VMATI plans was reduced by up to 55% (p = 5.8E-10) and MUs reduced by up to 16% (p = 0.001). Integral dose was not statistically different between the two planning techniques (p = 0.99). There were no statistically significant differences found in dose distribution of the two VMAT techniques (VMATI vs. VMATII) Dose statistics for both VMAT techniques were: PTV D99 (p = 0.76), PTV D95 (p = 0.95), mean PTV dose (p = 0.78), conformation number (CN) (p = 0.26), and MUs (p = 0.1). However, the treatment delivery time for VMATII increased significantly by two-fold (p = 3.0E-11) compared to VMATI. VMAT-based treatment planning is safe and deliverable for patients with thoracic esophageal cancer with similar planning goals, when compared to standard IMRT. The key benefit for VMATI was the reduction in treatment delivery time and MUs, and improvement in dose conformality. In our study, we found no significant difference in VMATII over single-arc VMATI for PTV coverage or OARs doses. However, we observed significant increase in delivery time for VMATII compared to VMATI.
Hamzeiy, Hamid; Cox, Jürgen
2017-02-01
Computational workflows for mass spectrometry-based shotgun proteomics and untargeted metabolomics share many steps. Despite the similarities, untargeted metabolomics is lagging behind in terms of reliable fully automated quantitative data analysis. We argue that metabolomics will strongly benefit from the adaptation of successful automated proteomics workflows to metabolomics. MaxQuant is a popular platform for proteomics data analysis and is widely considered to be superior in achieving high precursor mass accuracies through advanced nonlinear recalibration, usually leading to five to ten-fold better accuracy in complex LC-MS/MS runs. This translates to a sharp decrease in the number of peptide candidates per measured feature, thereby strongly improving the coverage of identified peptides. We argue that similar strategies can be applied to untargeted metabolomics, leading to equivalent improvements in metabolite identification. Copyright © 2016 The Author(s). Published by Elsevier Ltd.. All rights reserved.
Target coverage in image-guided stereotactic body radiotherapy of liver tumors.
Wunderink, Wouter; Méndez Romero, Alejandra; Vásquez Osorio, Eliana M; de Boer, Hans C J; Brandwijk, René P; Levendag, Peter C; Heijmen, Ben J M
2007-05-01
To determine the effect of image-guided procedures (with computed tomography [CT] and electronic portal images before each treatment fraction) on target coverage in stereotactic body radiotherapy for liver patients using a stereotactic body frame (SBF) and abdominal compression. CT guidance was used to correct for day-to-day variations in the tumor's mean position in the SBF. By retrospectively evaluating 57 treatment sessions, tumor coverage, as obtained with the clinically applied CT-guided protocol, was compared with that of alternative procedures. The internal target volume-plus (ITV(+)) was introduced to explicitly include uncertainties in tumor delineations resulting from CT-imaging artifacts caused by residual respiratory motion. Tumor coverage was defined as the volume overlap of the ITV(+), derived from a tumor delineated in a treatment CT scan, and the planning target volume. Patient stability in the SBF, after acquisition of the treatment CT scan, was evaluated by measuring the displacement of the bony anatomy in the electronic portal images relative to CT. Application of our clinical protocol (with setup corrections following from manual measurements of the distances between the contours of the planning target volume and the daily clinical target volume in three orthogonal planes, multiple two-dimensional) increased the frequency of nearly full (> or = 99%) ITV(+) coverage to 77% compared with 63% without setup correction. An automated three-dimensional method further improved the frequency to 96%. Patient displacements in the SBF were generally small (< or = 2 mm, 1 standard deviation), but large craniocaudal displacements (maximal 7.2 mm) were occasionally observed. Daily, CT-assisted patient setup may substantially improve tumor coverage, especially with the automated three-dimensional procedure. In the present treatment design, patient stability in the SBF should be verified with portal imaging.
Tonetti, Maurizio S; Cortellini, Pierpaolo; Pellegrini, Gaia; Nieri, Michele; Bonaccini, Daniele; Allegri, Mario; Bouchard, Philippe; Cairo, Francesco; Conforti, Gianpaolo; Fourmousis, Ioannis; Graziani, Filippo; Guerrero, Adrian; Halben, Jan; Malet, Jacques; Rasperini, Giulio; Topoll, Heinz; Wachtel, Hannes; Wallkamm, Beat; Zabalegui, Ion; Zuhr, Otto
2018-01-01
To evaluate the non-inferiority of the adjunct of a xenogeneic collagen matrix (CMX) or connective tissue graft (CTG) to coronally advanced flaps (CAF) for coverage of multiple adjacent recessions and compare superiority in patient-reported outcomes (PROM). One hundred and eighty-seven subjects (92 CMX) with 485 recessions in 14 centres were randomized and followed up for 6 months. Patients filled daily diaries for 15 days to monitor patient-reported experience. The primary outcome was changed in position of the gingival margin. Multilevel analysis used centre, subject and tooth as levels and baseline parameters as covariates. Average baseline recession was 2.5 ± 1.0 mm. The surgery was 15.7 min shorter (95%CI from 11.9 to 19.6, p < .0001) and perceived lighter (11.9 VAS units, 95%CI from 4.6 to 19.1, p = .0014) in CMX subjects. Time to recovery was 1.8 days shorter in CMX. Six-month root coverage was 1.7 ± 1.1 mm for CMX and 2.1 ± 1.0 mm for CTG (difference of 0.44 mm, 95%CI from 0.25 to 0.63 mm). The upper limit of the confidence interval was over the non-inferiority margin of 0.25 mm. Odds of complete root coverage were significantly higher for CTG (OR = 4.0, 95% CI 1.8-8.8). Replacing CTG with CMX shortens time to recovery and decreases morbidity, but the tested generation of devices is probably inferior to autologous CTG in terms of root coverage. Significant variability in PROMs was observed among centres. © 2017 The Authors. Journal of Clinical Periodontology Published by John Wiley & Sons Ltd.
Constrained motion model of mobile robots and its applications.
Zhang, Fei; Xi, Yugeng; Lin, Zongli; Chen, Weidong
2009-06-01
Target detecting and dynamic coverage are fundamental tasks in mobile robotics and represent two important features of mobile robots: mobility and perceptivity. This paper establishes the constrained motion model and sensor model of a mobile robot to represent these two features and defines the k -step reachable region to describe the states that the robot may reach. We show that the calculation of the k-step reachable region can be reduced from that of 2(k) reachable regions with the fixed motion styles to k + 1 such regions and provide an algorithm for its calculation. Based on the constrained motion model and the k -step reachable region, the problems associated with target detecting and dynamic coverage are formulated and solved. For target detecting, the k-step detectable region is used to describe the area that the robot may detect, and an algorithm for detecting a target and planning the optimal path is proposed. For dynamic coverage, the k-step detected region is used to represent the area that the robot has detected during its motion, and the dynamic-coverage strategy and algorithm are proposed. Simulation results demonstrate the efficiency of the coverage algorithm in both convex and concave environments.
Influenza vaccination coverage among US children from 2004/2005 to 2015/2016.
Tian, Changwei; Wang, Hua; Wang, Wenming; Luo, Xiaoming
2018-05-15
Quantify the influenza vaccine coverage is essential to identify emerging concerns and to immunization programs for targeting interventions. Data from National Health Interview Survey were used to estimate receipt of at least one dose of influenza vaccination among children 6 months to 17 years of age. Influenza vaccination coverage increased from 16.70% during 2004/2005 to 49.43% during 2015/2016 (3.18% per year, P < 0.001); however, the coverage increased slightly after 2010/2011. Children at high risk of influenza complications had higher influenza vaccination coverage than non at-risk children. Boys and girls had similar coverage each year. While the coverage increased from 2004/2005 to 2015/2016 for all age groups, the coverage decreased with age each year (-0.64 to -1.58% per age group). There was a higher and rapid increase of coverage in Northeast than Midwest, South and West. American Indian or Alaskan Native and Asian showed higher coverage than other race groups (White, Black/African American, Multiple race). Multivariable analysis showed that high-risk status and region had the greatest associations with levels of vaccine coverage. Although the influenza vaccination coverage among children had increased remarkably since 2004/2005, establishing more effective immunization programs are warranted to achieve the Healthy People 2020 target.
Killeen, Gerry F; Smith, Tom A; Ferguson, Heather M; Mshinda, Hassan; Abdulla, Salim; Lengeler, Christian; Kachur, Steven P
2007-01-01
Background Malaria prevention in Africa merits particular attention as the world strives toward a better life for the poorest. Insecticide-treated nets (ITNs) represent a practical means to prevent malaria in Africa, so scaling up coverage to at least 80% of young children and pregnant women by 2010 is integral to the Millennium Development Goals (MDG). Targeting individual protection to vulnerable groups is an accepted priority, but community-level impacts of broader population coverage are largely ignored even though they may be just as important. We therefore estimated coverage thresholds for entire populations at which individual- and community-level protection are equivalent, representing rational targets for ITN coverage beyond vulnerable groups. Methods and Findings Using field-parameterized malaria transmission models, we show that high (80% use) but exclusively targeted coverage of young children and pregnant women (representing <20% of the population) will deliver limited protection and equity for these vulnerable groups. In contrast, relatively modest coverage (35%–65% use, with this threshold depending on ecological scenario and net quality) of all adults and children, rather than just vulnerable groups, can achieve equitable community-wide benefits equivalent to or greater than personal protection. Conclusions Coverage of entire populations will be required to accomplish large reductions of the malaria burden in Africa. While coverage of vulnerable groups should still be prioritized, the equitable and communal benefits of wide-scale ITN use by older children and adults should be explicitly promoted and evaluated by national malaria control programmes. ITN use by the majority of entire populations could protect all children in such communities, even those not actually covered by achieving existing personal protection targets of the MDG, Roll Back Malaria Partnership, or the US President's Malaria Initiative. PMID:17608562
2012-01-01
Background In November 2009, Sierra Leone conducted a preventive yellow fever (YF) vaccination campaign targeting individuals aged nine months and older in six health districts. The campaign was integrated with a measles follow-up campaign throughout the country targeting children aged 9–59 months. For both campaigns, the operational objective was to reach 95% of the target population. During the campaign, we used clustered lot quality assurance sampling (C-LQAS) to identify areas of low coverage to recommend timely mop-up actions. Methods We divided the country in 20 non-overlapping lots. Twelve lots were targeted by both vaccinations, while eight only by measles. In each lot, five clusters of ten eligible individuals were selected for each vaccine. The upper threshold (UT) was set at 90% and the lower threshold (LT) at 75%. A lot was rejected for low vaccination coverage if more than 7 unvaccinated individuals (not presenting vaccination card) were found. After the campaign, we plotted the C-LQAS results against the post-campaign coverage estimations to assess if early interventions were successful enough to increase coverage in the lots that were at the level of rejection before the end of the campaign. Results During the last two days of campaign, based on card-confirmed vaccination status, five lots out of 20 (25.0%) failed for having low measles vaccination coverage and three lots out of 12 (25.0%) for low YF coverage. In one district, estimated post-campaign vaccination coverage for both vaccines was still not significantly above the minimum acceptable level (LT = 75%) even after vaccination mop-up activities. Conclusion C-LQAS during the vaccination campaign was informative to identify areas requiring mop-up activities to reach the coverage target prior to leaving the region. The only district where mop-up activities seemed to be unsuccessful might have had logistical difficulties that should be further investigated and resolved. PMID:22676225
Clinical applications of advanced rotational radiation therapy
NASA Astrophysics Data System (ADS)
Nalichowski, Adrian
Purpose: With a fast adoption of emerging technologies, it is critical to fully test and understand its limits and capabilities. In this work we investigate new graphic processing unit (GPU) based treatment planning algorithm and its applications in helical tomotherapy dose delivery. We explore the limits of the system by applying it to challenging clinical cases of total marrow irradiation (TMI) and stereotactic radiosurgery (SRS). We also analyze the feasibility of alternative fractionation schemes for total body irradiation (TBI) and TMI based on reported historical data on lung dose and interstitial pneumonitis (IP) incidence rates. Methods and Materials: An anthropomorphic phantom was used to create TMI plans using the new GPU based treatment planning system and the existing CPU cluster based system. Optimization parameters were selected based on clinically used values for field width, modulation factor and pitch. Treatment plans were also created on Eclipse treatment planning system (Varian Medical Systems Inc, Palo Alto, CA) using volumetric modulated arc therapy (VMAT) for dose delivery on IX treatment unit. A retrospective review was performed of 42 publications that reported IP rates along with lung dose, fractionation regimen, dose rate and chemotherapy. The analysis consisted of nearly thirty two hundred patients and 34 unique radiation regimens. Multivariate logistic regression was performed to determine parameters associated with IP and establish does response function. Results: The results showed very good dosimetric agreement between the GPU and CPU calculated plans. The results from SBRT study show that GPU planning system can maintain 90% target coverage while meeting all the constraints of RTOG 0631 protocol. Beam on time for Tomotherapy and flattening filter free RapidArc was much faster than for Vero or Cyberknife. Retrospective data analysis showed that lung dose and Cyclophosphomide (Cy) are both predictors of IP in TBI/TMI treatments. The dose rate was not found to be an independent risk factor for IP. The model failed to establish accurate dose response function, but the discrete data indicated a radiation dose threshold of 7.6Gy (EQD2_repair) and 120 mg/kg of Cy below which no IP cases were reported. Conclusion: The TomoTherapy GPU based dose engine is capable of calculating TMI treatment plans with plan quality nearly identical to plans calculated using the traditional CPU/cluster based system, while significantly reducing the time required for optimization and dose calculation. The new system was able to achieve more uniform dose distribution throughout the target volume and steeper dose fall off, resulting in superior OAR sparing when compared to Eclipse treatment planning system for VMAT delivery. The machine optimization parameters tested for TMI cases provide a comprehensive overview of the capabilities of the treatment planning station and associated helical delivery system. The new system also proved to be dosimetrically compatible with other leading modalities for treatments of small and complicated target volumes and was even superior when treatment delivery times were compared. These finding demonstrate that the advanced treatment planning and delivery system from TomoTherapy is well suitable for treatments of complicated cases such as TMI and SRS and it's often dosimetrically and/or logistically superior to other modalities. The new planning system can easily meet the constraint of threshold lung dose established in this study. The results presented here on the capabilities of Tomotherapy and on the identified lung dose threshold provide an opportunity to explore alternative fractionation schemes without sacrificing target coverage or lung toxicity. (Abstract shortened by ProQuest.).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xu Huijun; Gordon, J. James; Siebers, Jeffrey V.
2011-02-15
Purpose: A dosimetric margin (DM) is the margin in a specified direction between a structure and a specified isodose surface, corresponding to a prescription or tolerance dose. The dosimetric margin distribution (DMD) is the distribution of DMs over all directions. Given a geometric uncertainty model, representing inter- or intrafraction setup uncertainties or internal organ motion, the DMD can be used to calculate coverage Q, which is the probability that a realized target or organ-at-risk (OAR) dose metric D{sub v} exceeds the corresponding prescription or tolerance dose. Postplanning coverage evaluation quantifies the percentage of uncertainties for which target and OAR structuresmore » meet their intended dose constraints. The goal of the present work is to evaluate coverage probabilities for 28 prostate treatment plans to determine DMD sampling parameters that ensure adequate accuracy for postplanning coverage estimates. Methods: Normally distributed interfraction setup uncertainties were applied to 28 plans for localized prostate cancer, with prescribed dose of 79.2 Gy and 10 mm clinical target volume to planning target volume (CTV-to-PTV) margins. Using angular or isotropic sampling techniques, dosimetric margins were determined for the CTV, bladder and rectum, assuming shift invariance of the dose distribution. For angular sampling, DMDs were sampled at fixed angular intervals {omega} (e.g., {omega}=1 deg., 2 deg., 5 deg., 10 deg., 20 deg.). Isotropic samples were uniformly distributed on the unit sphere resulting in variable angular increments, but were calculated for the same number of sampling directions as angular DMDs, and accordingly characterized by the effective angular increment {omega}{sub eff}. In each direction, the DM was calculated by moving the structure in radial steps of size {delta}(=0.1,0.2,0.5,1 mm) until the specified isodose was crossed. Coverage estimation accuracy {Delta}Q was quantified as a function of the sampling parameters {omega} or {omega}{sub eff} and {delta}. Results: The accuracy of coverage estimates depends on angular and radial DMD sampling parameters {omega} or {omega}{sub eff} and {delta}, as well as the employed sampling technique. Target |{Delta}Q|<1% and OAR |{Delta}Q|<3% can be achieved with sampling parameters {omega} or {omega}{sub eff}=20 deg., {delta}=1 mm. Better accuracy (target |{Delta}Q|<0.5% and OAR |{Delta}Q|<{approx}1%) can be achieved with {omega} or {omega}{sub eff}=10 deg., {delta}=0.5 mm. As the number of sampling points decreases, the isotropic sampling method maintains better accuracy than fixed angular sampling. Conclusions: Coverage estimates for post-planning evaluation are essential since coverage values of targets and OARs often differ from the values implied by the static margin-based plans. Finer sampling of the DMD enables more accurate assessment of the effect of geometric uncertainties on coverage estimates prior to treatment. DMD sampling with {omega} or {omega}{sub eff}=10 deg. and {delta}=0.5 mm should be adequate for planning purposes.« less
Xu, Huijun; Gordon, J James; Siebers, Jeffrey V
2011-02-01
A dosimetric margin (DM) is the margin in a specified direction between a structure and a specified isodose surface, corresponding to a prescription or tolerance dose. The dosimetric margin distribution (DMD) is the distribution of DMs over all directions. Given a geometric uncertainty model, representing inter- or intrafraction setup uncertainties or internal organ motion, the DMD can be used to calculate coverage Q, which is the probability that a realized target or organ-at-risk (OAR) dose metric D, exceeds the corresponding prescription or tolerance dose. Postplanning coverage evaluation quantifies the percentage of uncertainties for which target and OAR structures meet their intended dose constraints. The goal of the present work is to evaluate coverage probabilities for 28 prostate treatment plans to determine DMD sampling parameters that ensure adequate accuracy for postplanning coverage estimates. Normally distributed interfraction setup uncertainties were applied to 28 plans for localized prostate cancer, with prescribed dose of 79.2 Gy and 10 mm clinical target volume to planning target volume (CTV-to-PTV) margins. Using angular or isotropic sampling techniques, dosimetric margins were determined for the CTV, bladder and rectum, assuming shift invariance of the dose distribution. For angular sampling, DMDs were sampled at fixed angular intervals w (e.g., w = 1 degree, 2 degrees, 5 degrees, 10 degrees, 20 degrees). Isotropic samples were uniformly distributed on the unit sphere resulting in variable angular increments, but were calculated for the same number of sampling directions as angular DMDs, and accordingly characterized by the effective angular increment omega eff. In each direction, the DM was calculated by moving the structure in radial steps of size delta (=0.1, 0.2, 0.5, 1 mm) until the specified isodose was crossed. Coverage estimation accuracy deltaQ was quantified as a function of the sampling parameters omega or omega eff and delta. The accuracy of coverage estimates depends on angular and radial DMD sampling parameters omega or omega eff and delta, as well as the employed sampling technique. Target deltaQ/ < l% and OAR /deltaQ/ < 3% can be achieved with sampling parameters omega or omega eef = 20 degrees, delta =1 mm. Better accuracy (target /deltaQ < 0.5% and OAR /deltaQ < approximately 1%) can be achieved with omega or omega eff = 10 degrees, delta = 0.5 mm. As the number of sampling points decreases, the isotropic sampling method maintains better accuracy than fixed angular sampling. Coverage estimates for post-planning evaluation are essential since coverage values of targets and OARs often differ from the values implied by the static margin-based plans. Finer sampling of the DMD enables more accurate assessment of the effect of geometric uncertainties on coverage estimates prior to treatment. DMD sampling with omega or omega eff = 10 degrees and delta = 0.5 mm should be adequate for planning purposes.
ERIC Educational Resources Information Center
Moss, Nancy
1990-01-01
As the shrinking pool of applicants forces colleges to adapt new approaches to recruiting, media campaigns are emerging as an effective way to send key messages to target audiences. Media relations can lend credibility (news coverage is considered more credible than advertising); save money; reach targeted areas; and communicate key themes. (MLW)
An, Wei; Liu, Ping
2016-09-07
When using the TiO 2(110)-supported Pd7 cluster as a model catalyst, we identified the dynamics of supported metal nanoparticles using density functional theory calculations, at the sub-nanometer scale and under reactive environments. Increasing the CO coverage can induce a structural transformation from Pd 7-3D/TiO 2(110) at low coverage to Pd 7-2D/TiO 2(110) at the saturation coverage wherein CO saturation-driven Pd7-2D/TiO 2(110) structure displays superior CO oxidation activity at the interfacial sites, which are highly active for catalyzing O 2 dissociation and CO oxidation via bifunctional synergy.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, Xin; Fang, Hui; Tian, Yuan
Purpose: To evaluate the dosimetric superiority, efficacy, toxicity, and quality of life (QOL) data of intensity modulated radiation therapy (IMRT) in patients with primary gastric diffuse large B-cell lymphoma (PG-DLBCL). Methods and Materials: Forty-six consecutive patients with early-stage PG-DLBCL underwent IMRT after chemotherapy. The majority of patients (61.5%) were subclassified as the non-germinal center B cell–like subtype. Dosimetric parameters of the planning target volume (PTV) and organs at risk were assessed. Survival rates were depicted with the Kaplan-Meier method and compared with the log-rank test. Quality of life was evaluated using the QLQ-C30-STO22 questionnaires at the last follow-up contact. Results: Themore » median PTV mean dose was 41.6 Gy. Only 0.73% of the PTV received <95% of the prescribed dose, indicating excellent target coverage. The median kidney V20 and liver V30 were 14.1% and 16.1%, respectively. The 5-year overall survival (OS), progression-free survival, and locoregional control rates for all patients were 80.4%, 75.0%, and 93.2%, respectively. Stage, lactate dehydrogenase level, and immunophenotype were significant prognostic factors for OS, and only stage was a significant factor for locoregional control. Consolidation IMRT in patients with complete response after chemotherapy resulted in significantly better OS and progression-free survival than salvage IMRT in patients with non-complete response. Two of 8 patients who had chronic liver disease experienced grade 4 or grade 5 acute hepatic failure after 4 to 5 cycles of rituximab-based chemotherapy and IMRT (40 Gy). No other serious acute or late toxicity was observed. The long-term global and functional QOL scales were excellent, with negligible symptom scales. Conclusions: Intensity modulated radiation therapy yielded excellent target coverage and critical tissue sparing and achieved favorable outcomes with acceptable toxicity and good long-term QOL in early-stage PG-DLBCL.« less
Ko, Young Eun; Cho, Byungchul; Kim, Su Ssan; Song, Si Yeol; Choi, Eun Kyung; Ahn, Seung Do; Yi, Byongyong
2016-01-01
Purpose To develop a simplified volumetric modulated arc therapy (VMAT) technique for more accurate dose delivery in thoracic stereotactic body radiation therapy (SBRT). Methods and Materials For each of the 22 lung SBRT cases treated with respiratory-gated VMAT, a dose rate modulated arc therapy (DrMAT) plan was retrospectively generated. A dynamic conformal arc therapy plan with 33 adjoining coplanar arcs was designed and their beam weights were optimized by an inverse planning process. All sub-arc beams were converted into a series of control points with varying MLC segment and dose rates and merged into an arc beam for a DrMAT plan. The plan quality of original VMAT and DrMAT was compared in terms of target coverage, compactness of dose distribution, and dose sparing of organs at risk. To assess the delivery accuracy, the VMAT and DrMAT plans were delivered to a motion phantom programmed with the corresponding patients’ respiratory signal; results were compared using film dosimetry with gamma analysis. Results The plan quality of DrMAT was equivalent to that of VMAT in terms of target coverage, dose compactness, and dose sparing for the normal lung. In dose sparing for other critical organs, DrMAT was less effective than VMAT for the spinal cord, heart, and esophagus while being well within the limits specified by the Radiation Therapy Oncology Group. Delivery accuracy of DrMAT to a moving target was similar to that of VMAT using a gamma criterion of 2%/2mm but was significantly better using a 2%/1mm criterion, implying the superiority of DrMAT over VMAT in SBRT for thoracic/abdominal tumors with respiratory movement. Conclusion We developed a DrMAT technique for SBRT that produces plans of a quality similar to that achieved with VMAT but with better delivery accuracy. This technique is well-suited for small tumors with motion uncertainty. PMID:27333199
Deardorff, Katrina V; Rubin Means, Arianna; Ásbjörnsdóttir, Kristjana H; Walson, Judd
2018-02-01
Community-based public health campaigns, such as those used in mass deworming, vitamin A supplementation and child immunization programs, provide key healthcare interventions to targeted populations at scale. However, these programs often fall short of established coverage targets. The purpose of this systematic review was to evaluate the impact of strategies used to increase treatment coverage in community-based public health campaigns. We systematically searched CAB Direct, Embase, and PubMed archives for studies utilizing specific interventions to increase coverage of community-based distribution of drugs, vaccines, or other public health services. We identified 5,637 articles, from which 79 full texts were evaluated according to pre-defined inclusion and exclusion criteria. Twenty-eight articles met inclusion criteria and data were abstracted regarding strategy-specific changes in coverage from these sources. Strategies used to increase coverage included community-directed treatment (n = 6, pooled percent change in coverage: +26.2%), distributor incentives (n = 2, +25.3%), distribution along kinship networks (n = 1, +24.5%), intensified information, education, and communication activities (n = 8, +21.6%), fixed-point delivery (n = 1, +21.4%), door-to-door delivery (n = 1, +14.0%), integrated service distribution (n = 9, +12.7%), conversion from school- to community-based delivery (n = 3, +11.9%), and management by a non-governmental organization (n = 1, +5.8%). Strategies that target improving community member ownership of distribution appear to have a large impact on increasing treatment coverage. However, all strategies used to increase coverage successfully did so. These results may be useful to National Ministries, programs, and implementing partners in optimizing treatment coverage in community-based public health programs.
2018-01-01
Background Community-based public health campaigns, such as those used in mass deworming, vitamin A supplementation and child immunization programs, provide key healthcare interventions to targeted populations at scale. However, these programs often fall short of established coverage targets. The purpose of this systematic review was to evaluate the impact of strategies used to increase treatment coverage in community-based public health campaigns. Methodology/ principal findings We systematically searched CAB Direct, Embase, and PubMed archives for studies utilizing specific interventions to increase coverage of community-based distribution of drugs, vaccines, or other public health services. We identified 5,637 articles, from which 79 full texts were evaluated according to pre-defined inclusion and exclusion criteria. Twenty-eight articles met inclusion criteria and data were abstracted regarding strategy-specific changes in coverage from these sources. Strategies used to increase coverage included community-directed treatment (n = 6, pooled percent change in coverage: +26.2%), distributor incentives (n = 2, +25.3%), distribution along kinship networks (n = 1, +24.5%), intensified information, education, and communication activities (n = 8, +21.6%), fixed-point delivery (n = 1, +21.4%), door-to-door delivery (n = 1, +14.0%), integrated service distribution (n = 9, +12.7%), conversion from school- to community-based delivery (n = 3, +11.9%), and management by a non-governmental organization (n = 1, +5.8%). Conclusions/significance Strategies that target improving community member ownership of distribution appear to have a large impact on increasing treatment coverage. However, all strategies used to increase coverage successfully did so. These results may be useful to National Ministries, programs, and implementing partners in optimizing treatment coverage in community-based public health programs. PMID:29420534
A method for deriving a 4D-interpolated balanced planning target for mobile tumor radiotherapy.
Roland, Teboh; Hales, Russell; McNutt, Todd; Wong, John; Simari, Patricio; Tryggestad, Erik
2012-01-01
Tumor control and normal tissue toxicity are strongly correlated to the tumor and normal tissue volumes receiving high prescribed dose levels in the course of radiotherapy. Planning target definition is, therefore, crucial to ensure favorable clinical outcomes. This is especially important for stereotactic body radiation therapy of lung cancers, characterized by high fractional doses and steep dose gradients. The shift in recent years from population-based to patient-specific treatment margins, as facilitated by the emergence of 4D medical imaging capabilities, is a major improvement. The commonly used motion-encompassing, or internal-target volume (ITV), target definition approach provides a high likelihood of coverage for the mobile tumor but inevitably exposes healthy tissue to high prescribed dose levels. The goal of this work was to generate an interpolated balanced planning target that takes into account both tumor coverage and normal tissue sparing from high prescribed dose levels, thereby improving on the ITV approach. For each 4DCT dataset, 4D deformable image registration was used to derive two bounding targets, namely, a 4D-intersection and a 4D-composite target which minimized normal tissue exposure to high prescribed dose levels and maximized tumor coverage, respectively. Through definition of an "effective overlap volume histogram" the authors derived an "interpolated balanced planning target" intended to balance normal tissue sparing from prescribed doses with tumor coverage. To demonstrate the dosimetric efficacy of the interpolated balanced planning target, the authors performed 4D treatment planning based on deformable image registration of 4D-CT data for five previously treated lung cancer patients. Two 4D plans were generated per patient, one based on the interpolated balanced planning target and the other based on the conventional ITV target. Plans were compared for tumor coverage and the degree of normal tissue sparing resulting from the new approach was quantified. Analysis of the 4D dose distributions from all five patients showed that while achieving tumor coverage comparable to the ITV approach, the new planning target definition resulted in reductions of lung V(10), V(20), and V(30) of 6.3% ± 1.7%, 10.6% ± 3.9%, and 12.9% ± 5.5%, respectively, as well as reductions in mean lung dose, mean dose to the GTV-ring and mean heart dose of 8.8% ± 2.5%, 7.2% ± 2.5%, and 10.6% ± 3.6%, respectively. The authors have developed a simple and systematic approach to generate a 4D-interpolated balanced planning target volume that implicitly incorporates the dynamics of respiratory-organ motion without requiring 4D-dose computation or optimization. Preliminary results based on 4D-CT data of five previously treated lung patients showed that this new planning target approach may improve normal tissue sparing without sacrificing tumor coverage.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sheng, Yang, E-mail: Yang.Sheng@duke.edu; Medical Physics Graduate Program, Duke University, Durham, North Carolina; Li, Taoran
Purpose: To provide a benchmark for seminal vesicle (SV) margin selection to account for intrafractional motion and to investigate the effectiveness of 2 motion surrogates in predicting intrafractional SV coverage. Methods and Materials: Fifteen prostate patients were studied. Each patient had 5 pairs (1 patient had 4 pairs) of pretreatment and posttreatment cone beam CTs (CBCTs). Each pair of CBCTs was registered on the basis of prostate fiducial markers. All pretreatment SVs were expanded with 1-, 2-, 3-, 4-, 5-, and 8-mm isotropic margins to form a series of planning target volumes, and their intrafractional coverage to the posttreatment SVmore » determined the “ground truth” for exact coverage. Two motion surrogates, the center of mass (COM) and the border of contour, were evaluated by the use of Pearson product-moment correlation coefficient and exponential fitting for predicting SV underdosage. Action threshold of each surrogate was calculated. The margin for each surrogate was calculated according to a traditional margin recipe. Results: Ninety-five percent posttreatment SV coverage was achieved in 9%, 53%, 73%, 86%, 95%, and 97% of fractions with 1-, 2-, 3-, 4-, 5-, and 8-mm margins, respectively. The 5-mm margins provided 95% intrafractional SV coverage in over 90% of fractions. The correlation between the COM and border was weak, moderate, and strong in the left-right (L-R), anterior-posterior (A-P), and superior-inferior (S-I) directions, respectively. Exponential fitting gave the underdosage threshold of 4.5 and 7.0 mm for the COM and border. The Van Herk margin recipe recommended 0-, 0.5-, and 0.8-mm margins in the L-R, A-P, and S-I directions based on the COM, and 1.2-, 3.9-, and 2.5-mm margins based on the border. Conclusions: Five-millimeter isotropic margins for the SV constitute the minimum required to mitigate the intrafractional motion. Both the COM and the border are acceptable predictors for SV underdosage with 4.5- and 7.0-mm action threshold. Traditional margin based on the COM or border underestimates the margin.« less
To close the childhood immunization gap, we need a richer understanding of parents' decision-making.
Corben, Paul; Leask, Julie
2016-12-01
Vaccination is widely acknowledged as one of the most successful public health interventions globally and in most high-income countries childhood vaccination coverage rates are moderately high. Yet in many instances, immunisation rates remain below aspirational targets and have shown only modest progress toward those targets in recent years, despite concerted efforts to improve uptake. In part, coverage rates reflect individual parents' vaccination attitudes and decisions and, because vaccination decision-making is complex and context-specific, it remains challenging at individual and community levels to assist parents to make positive decisions. Consequently, in the search for opportunities to improve immunisation coverage, there has been a renewed research focus on parents' decision-making. This review provides an overview of the literature surrounding parents' vaccination decision-making, offering suggestions for where efforts to increase vaccination coverage should be targeted and identifying areas for further research.
Bi-tangential hybrid IMRT for sparing the shoulder in whole breast irradiation.
Farace, P; Deidda, M A; Iamundo de Cumis, I; Iamundo de Curtis, I; Deiana, E; Farigu, R; Lay, G; Porru, S
2013-11-01
A bi-tangential technique is proposed to reduce undesired doses to the shoulder produced by standard tangential irradiation. A total of 6 patients affected by shoulder pain and reduced functional capacity after whole-breast irradiation were retrospectively analysed. The standard tangential plan used for treatment was compared with (1) a single bi-tangential plan where, to spare the shoulder, the lateral open tangent was split into two half-beams at isocentre, with the superior portion rotated by 10-20° medially with respect to the standard lateral beam; (2) a double bi-tangential plan, where both the tangential open beams were split. The planning target volume (PTV) coverage and the dose to the portion of muscles and axilla included in the standard tangential beams were compared. PTV95 % of standard plan (91.9 ± 3.8) was not significantly different from single bi-tangential plan (91.8 ± 3.4); a small but significant (p < 0.01) decrease was observed with the double bi-tangential plan (90.1 ± 3.7). A marked dose reduction to the muscle was produced by the single bi-tangential plan around 30-40 Gy. The application of the double bi-tangential technique further reduced the volume receiving around 20 Gy, but did not markedly affect the higher doses. The dose to the axilla was reduced both in the single and the double bi-tangential plans. The single bi-tangential technique would have been able to reduce the dose to shoulder and axilla, without compromising target coverage. This simple technique is valuable for irradiation after axillary lymph node dissection or in patients without dissection due to negative or low-volume sentinel lymph node disease.
Iridium-Knife: Another knife in radiation oncology.
Milickovic, Natasa; Tselis, Nikolaos; Karagiannis, Efstratios; Ferentinos, Konstantinos; Zamboglou, Nikolaos
Intratarget dose escalation with superior conformity is a defining feature of three-dimensional (3D) iridium-192 ( 192 Ir) high-dose-rate (HDR) brachytherapy (BRT). In this study, we analyzed the dosimetric characteristics of interstitial 192 Ir HDR BRT for intrathoracic and cerebral malignancies. We examined the dose gradient sharpness of HDR BRT compared with that of linear accelerator-based stereotactic radiosurgery and stereotactic body radiation therapy, usually called X-Knife, to demonstrate that it may as well be called a Knife. Treatment plans for 10 patients with recurrent glioblastoma multiforme or intrathoracic malignancies, five of each entity, treated with X-Knife (stereotactic radiosurgery for glioblastoma multiforme and stereotactic body radiation therapy for intrathoracic malignancies) were replanned for simulated HDR BRT. For 3D BRT planning, we used identical structure sets and dose prescription as for the X-Knife planning. The indices for qualitative treatment plan analysis encompassed planning target volume coverage, conformity, dose falloff gradient, and the maximum dose-volume limits to different organs at risk. Volume coverage in HDR plans was comparable to that calculated for X-Knife plans with no statistically significant difference in terms of conformity. The dose falloff gradient-sharpness-of the HDR plans was considerably steeper compared with the X-Knife plans. Both 3D 192 Ir HDR BRT and X-Knife are effective means for intratarget dose escalation with HDR BRT achieving at least equal conformity and a steeper dose falloff at the target volume margin. In this sense, it can reasonably be argued that 3D 192 Ir HDR BRT deserves also to be called a Knife, namely Iridium-Knife. Copyright © 2017 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Qiao, L; Deng, G; Xie, J
2015-06-15
Purpose: To compare the dosimetric characteristics of volumetric-modulated arc therapy (VMAT) and intensity-modulated radiotherapy (IMRT) techniques in treatment planning for left-sided breast cancer patients with modified radical mastectomy. Methods: Twenty-four left-sided breast cancer patients treated with modified radical mastectomy were selected in this study. The planning target volume (PTV) was generated by using 7-mm uniform expansion of the clinical target volume (CTV) in all direction except the skin surface. The organs at risk (OARs) included heart, left lung, right lung, and right breast. Dose volume histograms (DVHs) were utilized to evaluate the dose distribution in PTV and OARs. Results: Bothmore » VMAT and IMRT plans met the requirement of PTV coverage. VMAT was superior to IMRT in terms of conformity, with a statistically significant difference (p=0.024). Mean doses, V5 and V10 of heart and both lungs in VMAT plans were significantly decreased compared to IMRT plans (P<0.05), but in terms of heart volume irradiated by high doses (V30 and V45), no significant differences were observed (P>0.05). For right breast, VMAT showed the reduction of V5 in comparison with IMRT (P<0.05). Additionally, the mean number of monitor units (MU) and treatment time in VMAT (357.21, 3.62 min) were significantly less than those in IMRT (1132.85, 8.74 min). Conclusion: VMAT showed similar PTV coverage and significant advantage in OARs sparing compared with IMRT, especially in terms of decreased volumes irradiated by low doses, while significantly reducing the treatment time and MU number.« less
An Anatomic and Biomechanical Comparison of Bankart Repair Configurations.
Judson, Christopher H; Voss, Andreas; Obopilwe, Elifho; Dyrna, Felix; Arciero, Robert A; Shea, Kevin P
2017-11-01
Suture anchor repair for anterior shoulder instability can be performed using a number of different repair techniques, but none has been proven superior in terms of anatomic and biomechanical properties. Purpose/Hypothesis: The purpose was to compare the anatomic footprint coverage and biomechanical characteristics of 4 different Bankart repair techniques: (1) single row with simple sutures, (2) single row with horizontal mattress sutures, (3) double row with sutures, and (4) double row with labral tape. The hypotheses were as follows: (1) double-row techniques would improve the footprint coverage and biomechanical properties compared with single-row techniques, (2) horizontal mattress sutures would increase the footprint coverage compared with simple sutures, and (3) repair techniques with labral tape and sutures would not show different biomechanical properties. Controlled laboratory study. Twenty-four fresh-frozen cadaveric specimens were dissected. The native labrum was removed and the footprint marked and measured. Repair for each of the 4 groups was performed, and the uncovered footprint was measured using a 3-dimensional digitizer. The strength of the repair sites was assessed using a servohydraulic testing machine and a digital video system to record load to failure, cyclic displacement, and stiffness. The double-row repair techniques with sutures and labral tape covered 73.4% and 77.0% of the footprint, respectively. These percentages were significantly higher than the footprint coverage achieved by single-row repair techniques using simple sutures (38.1%) and horizontal mattress sutures (32.8%) ( P < .001). The footprint coverage of the simple suture and horizontal mattress suture groups was not significantly different ( P = .44). There were no significant differences in load to failure, cyclic displacement, or stiffness between the single-row and double-row groups or between the simple suture and horizontal mattress suture techniques. Likewise, there was no difference in the biomechanical properties of the double-row repair techniques with sutures versus labral tape. Double-row repair techniques provided better coverage of the native footprint of the labrum but did not provide superior biomechanical properties compared with single-row repair techniques. There was no difference in footprint coverage or biomechanical strength between the simple suture and horizontal mattress suture repair techniques. Although the double-row repair techniques had no difference in initial strength, they may improve healing in high-risk patients by improving the footprint coverage.
Li, Xiadong; Wang, Lu; Wang, Jiahao; Han, Xu; Xia, Bing; Wu, Shixiu; Hu, Weigang
2017-01-01
This study aimed to design automated volumetric-modulated arc therapy (VMAT) plans in Pinnacle auto-planning and compare it with manual plans for patients with lower thoracic esophageal cancer (EC). Thirty patients with lower thoracic EC were randomly selected for replanning VMAT plans using auto-planning in Pinnacle treatment planning system (TPS) version 9.10. Historical plans of these patients were then compared. Dose-volume histogram (DVH) statistics, dose uniformity, and dose homogeneity were analyzed to evaluate treatment plans. Auto-planning was superior in terms of conformity index (CI) and homogeneity index (HI) for planning target volume (PTV), significantly improving 8.2% (p = 0.013) and 25% (p = 0.007) compared with manual planning, respectively, and decreasing dose of heart and liver irradiated by 20 to 40 Gy and 5 to 30 Gy, respectively (p < 0.05). Meanwhile, auto-planning further reduced the maximum dose (D max ) of spinal cord by 6.9 Gy compared with manual planning (p = 0.000). Additionally, manual planning showed the significantly lower low-dose volume (V 5 ) for the lung (p = 0.005). For auto-planning, the V 5 of the lung was significantly associated with the relative volume index (the volume ratio of PTV to the lung), and the correlation coefficient (R) and p-value were 0.994 and 0.000. Pinnacle auto-planning achieved superior target conformity and homogeneity and similar target coverage compared with historical manual planning. Most of organs at risk (OARs) sparing was significantly improved by auto-planning except for the V 5 of the lung, and the low dose distribution was highly associated with PTV volume and lung volume in auto-planning. Copyright © 2017 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.
Mallari, Neil Aldrin D; Collar, Nigel J; McGowan, Philip J K; Marsden, Stuart J
2016-04-01
Aichi Target 11 of the Convention on Biological Diversity urges, inter alia, that nations protect at least 17 % of their land, and that protection is effective and targets areas of importance for biodiversity. Five years before reporting on Aichi targets is due, we assessed the Philippines' current protected area system for biodiversity coverage, appropriateness of management regimes and capacity to deliver protection. Although protected estate already covers 11 % of the Philippines' land area, 64 % of its key biodiversity areas (KBAs) remain unprotected. Few protected areas have appropriate management and governance infrastructures, funding streams, management plans and capacity, and a serious mismatch exists between protected area land zonation regimes and conservation needs of key species. For the Philippines to meet the biodiversity coverage and management effectiveness elements of Aichi Target 11, protected area and KBA boundaries should be aligned, management systems reformed to pursue biodiversity-led targets and effective management capacity created.
Tyler, Madelaine K
2016-01-08
This study quantified the interplay and gradient effects on GTV dose coverage for 3D CRT, dMLC IMRT, and VMAT SABR treatments for target amplitudes of 5-30 mm using 3DVH v3.1 software incorporating 4D Respiratory MotionSim (4D RMS) module. For clinically relevant motion periods (5 s), the interplay effect was small, with deviations in the minimum dose covering the target volume (D99%) of less than ± 2.5% for target amplitudes up to 30 mm. Increasing the period to 60 s resulted in interplay effects of up to ± 15.0% on target D99% dose coverage. The gradient effect introduced by target motion resulted in deviations of up to ± 3.5% in D99% target dose coverage. VMAT treatments showed the largest deviation in dose metrics, which was attributed to the long delivery times in comparison to dMLC IMRT. Retrospective patient analysis indicated minimal interplay and gradient effects for patients treated with dMLC IMRT at the NCCI.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, JY; Hong, DL
Purpose: The purpose of this study is to investigate the patient set-up error and interfraction target coverage in cervical cancer using image-guided adaptive radiotherapy (IGART) with cone-beam computed tomography (CBCT). Methods: Twenty cervical cancer patients undergoing intensity modulated radiotherapy (IMRT) were randomly selected. All patients were matched to the isocenter using laser with the skin markers. Three dimensional CBCT projections were acquired by the Varian Truebeam treatment system. Set-up errors were evaluated by radiation oncologists, after CBCT correction. The clinical target volume (CTV) was delineated on each CBCT, and the planning target volume (PTV) coverage of each CBCT-CTVs was analyzed.more » Results: A total of 152 CBCT scans were acquired from twenty cervical cancer patients, the mean set-up errors in the longitudinal, vertical, and lateral direction were 3.57, 2.74 and 2.5mm respectively, without CBCT corrections. After corrections, these were decreased to 1.83, 1.44 and 0.97mm. For the target coverage, CBCT-CTV coverage without CBCT correction was 94% (143/152), and 98% (149/152) with correction. Conclusion: Use of CBCT verfication to measure patient setup errors could be applied to improve the treatment accuracy. In addition, the set-up error corrections significantly improve the CTV coverage for cervical cancer patients.« less
Range optimization for mono- and bi-energetic proton modulated arc therapy with pencil beam scanning
NASA Astrophysics Data System (ADS)
Sanchez-Parcerisa, Daniel; Kirk, Maura; Fager, Marcus; Burgdorf, Brendan; Stowe, Malorie; Solberg, Tim; Carabe, Alejandro
2016-11-01
The development of rotational proton therapy plans based on a pencil-beam-scanning (PBS) system has been limited, among several other factors, by the energy-switching time between layers, a system-dependent parameter that ranges between a fraction of a second and several seconds. We are investigating mono- and bi-energetic rotational proton modulated arc therapy (PMAT) solutions that would not be affected by long energy switching times. In this context, a systematic selection of the optimal proton energy for each arc is vital. We present a treatment planning comparison of four different range selection methods, analyzing the dosimetric outcomes of the resulting treatment plans created with the ranges obtained. Given the patient geometry and arc definition (gantry and couch trajectories, snout elevation) our in-house treatment planning system (TPS) FoCa was used to find the maximum, medial and minimum water-equivalent thicknesses (WETs) of the target viewed from all possible field orientations. Optimal ranges were subsequently determined using four methods: (1) by dividing the max/min WET interval into equal steps, (2) by taking the average target midpoints from each field, (3) by taking the average WET of all voxels from all field orientations, and (4) by minimizing the fraction of the target which cannot be reached from any of the available angles. After the range (for mono-energetic plans) or ranges (for bi-energetic plans) were selected, the commercial clinical TPS in use in our institution (Varian Eclipse™) was used to produce the PMAT plans using multifield optimization. Linear energy transfer (LET) distributions of all plans were also calculated using FoCa and compared among the different methods. Mono- and bi-energetic PMAT plans, composed of a single 180° arc, were created for two patient geometries: a C-shaped target located in the mediastinal area of a thoracic tissue-equivalent phantom and a small brain tumor located directly above the brainstem. All plans were optimized using the same procedure to (1) achieve target coverage, (2) reduce dose to OAR and (3) limit dose hot spots in the target. Final outcomes were compared in terms of the resulting dose and LET distributions. Data shows little significant differences among the four studied methods, with superior results obtained with mono-energetic plans. A streamlined systematic method has been implemented in an in-house TPS to find the optimal range to maximize target coverage with rotational mono- or bi-energetic PBS rotational plans by minimizing the fraction of the target that cannot be reached by any direction.
Levi, Jacob; Pozniak, Anton; Heath, Katherine; Hill, Andrew
2018-04-01
In 2014, UNAIDS and partners set the 90-90-90 targets for the HIV treatment cascade. Multiple social, political and structural factors might influence progress towards these targets. We assessed how close countries and regions are to reaching these targets, and compared cascade outcomes with HIV prevalence, gross domestic product (GDP)/capita, conflict and corruption. Country-level HIV cascade data on diagnosis, ART coverage and viral suppression, from 2010 to 2016 were extracted from national reports, published papers and the www.AIDSinfoOnline database, and analysed. Weighted least-squares regression was used to assess predictors of cascade achievement: region, HIV prevalence, GDP/capita, the 2016 Corruption Perceptions Index (CPI), which is an international ranking system, and the 2016 Global Peace Index (GPI), which ranks all countries based on three main categories: societal safety, militarisation and conflict. Data were available for diagnosis for 84 countries, ART coverage for 137 countries, and viral suppression for 94 countries. Regions with the lowest ART coverage were South-east Asia and Pacific (36%), Eastern Europe and Central Asia (17%), and Middle East and North Africa (13%). Lower HIV prevalence was associated with poorer cascade results. Countries with higher GDP/capita achieved higher ART coverage ( P <0.001). Furthermore, countries with lower levels of peace and higher corruption had lower ART coverage ( P <0.001). Countries with a GPI >2.5 all had ART coverage of <40%. Only one country has reached the UNAIDS 90-90-90 targets. International comparison remains difficult due to heterogeneous data reporting. Difficulty meeting UNAIDS targets is associated with lower GDP/capita, lower HIV prevalence, higher corruption and conflict levels.
Progress toward measles preelimination--African Region, 2011-2012.
Masresha, Balcha G; Kaiser, Reinhard; Eshetu, Messeret; Katsande, Reggis; Luce, Richard; Fall, Amadou; Dosseh, Annick R G A; Naouri, Boubker; Byabamazima, Charles R; Perry, Robert; Dabbagh, Alya J; Strebel, Peter; Kretsinger, Katrina; Goodson, James L; Nshimirimana, Deo
2014-04-04
In 2008, the 46 member states of the World Health Organization (WHO) African Region (AFR) adopted a measles preelimination goal to reach by the end of 2012 with the following targets: 1) >98% reduction in estimated regional measles mortality compared with 2000, 2) annual measles incidence of fewer than five reported cases per million population nationally, 3) >90% national first dose of measles-containing vaccine (MCV1) coverage and >80% MCV1 coverage in all districts, and 4) >95% MCV coverage in all districts by supplementary immunization activities (SIAs). Surveillance performance objectives were to report two or more cases of nonmeasles febrile rash illness per 100,000 population, one or more suspected measles cases investigated with blood specimens in ≥80% of districts, and 100% completeness of surveillance reporting from all districts. This report updates previous reports and describes progress toward the measles preelimination goal during 2011-2012. In 2012, 13 (28%) member states had >90% MCV1 coverage, and three (7%) reported >90% MCV1 coverage nationally and >80% coverage in all districts. During 2011-2012, four (15%) of 27 SIAs with available information met the target of >95% coverage in all districts. In 2012, 16 of 43 (37%) member states met the incidence target of fewer than five cases per million, and 19 of 43 (44%) met both surveillance performance targets. In 2011, the WHO Regional Committee for AFR established a goal to achieve measles elimination by 2020. To achieve this goal, intensified efforts to identify and close population immunity gaps and improve surveillance quality are needed, as well as committed leadership and ownership of the measles elimination activities and mobilization of adequate resources to complement funding from global partners.
Chi, Alexander; Ma, Pan; Fu, Guishan; Hobbs, Gerry; Welsh, James S.; Nguyen, Nam P.; Jang, Si Young; Dai, Jinrong; Jin, Jing; Komaki, Ritsuko
2013-01-01
Background Helical tomotherapy (HT) and volumetric modulated arc therapy (VMAT) are both advanced techniques of delivering intensity-modulated radiotherapy (IMRT). Here, we conduct a study to compare HT and partial-arc VMAT in their ability to spare organs at risk (OARs) when stereotactic ablative radiotherapy (SABR) is delivered to treat centrally located early stage non-small-cell lung cancer or lung metastases. Methods 12 patients with centrally located lung lesions were randomly chosen. HT, 2 & 8 arc (Smart Arc, Pinnacle v9.0) plans were generated to deliver 70 Gy in 10 fractions to the planning target volume (PTV). Target and OAR dose parameters were compared. Each technique’s ability to meet dose constraints was further investigated. Results HT and VMAT plans generated essentially equivalent PTV coverage and dose conformality indices, while a trend for improved dose homogeneity by increasing from 2 to 8 arcs was observed with VMAT. Increasing the number of arcs with VMAT also led to some improvement in OAR sparing. After normalizing to OAR dose constraints, HT was found to be superior to 2 or 8-arc VMAT for optimal OAR sparing (meeting all the dose constraints) (p = 0.0004). All dose constraints were met in HT plans. Increasing from 2 to 8 arcs could not help achieve optimal OAR sparing for 4 patients. 2/4 of them had 3 immediately adjacent structures. Conclusion HT appears to be superior to VMAT in OAR sparing mainly in cases which require conformal dose avoidance of multiple immediately adjacent OARs. For such cases, increasing the number of arcs in VMAT cannot significantly improve OAR sparing. PMID:23577071
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shibayama, Y; Umezu, Y; Nakamura, Y
2016-06-15
Purpose: Our assumption was that interfractional shape variations of target volumes could not be negligible for determination of clinical target volume (CTV)-to-planning target volume (PTV) margins. The aim of this study was to investigate this assumption as a simulation study by developing a computational framework of CTV-to-PTV margins with taking the interfractional shape variations into account based on point distribution model (PDM) Methods: The systematic and random errors for interfractional shape variations and translations of target volumes were evaluated for four types of CTV regions (only a prostate, a prostate plus proximal 1-cm seminal vesicles, a prostate plus proximal 2-cmmore » seminal vesicles, and a prostate plus whole seminal vesicles). The CTV regions were delineated depending on prostate cancer risk groups on planning computed tomography (CT) and cone beam CT (CBCT) images of 73 fractions of 10 patients. The random and systematic errors for shape variations of CTV regions were derived from PDMs of CTV surfaces for all fractions of each patient. Systematic errors of shape variations of CTV regions were derived by comparing PDMs between planning CTV surfaces and average CTV surfaces. Finally, anisotropic CTV-to-PTV margins with shape variations in 6 directions (anterior, posterior, superior, inferior, right, and left) were computed by using a van Herk margin formula. Results: Differences between CTV-to-PTV margins with and without shape variations ranged from 0.7 to 1.7 mm in anterior direction, 1.0 to 2.8 mm in posterior direction, 0.8 to 2.8 mm in superior direction, 0.6 to 1.6 mm in inferior direction, 1.4 to 4.4 mm in right direction, and 1.3 to 5.2 mm in left direction. Conclusion: More than 1.0 mm additional margins were needed at least in 3 directions to guarantee CTV coverage due to shape variations. Therefore, shape variations should be taken into account for the determination of CTV-to-PTV margins.« less
Multi-Objective Optimization of Spacecraft Trajectories for Small-Body Coverage Missions
NASA Technical Reports Server (NTRS)
Hinckley, David, Jr.; Englander, Jacob; Hitt, Darren
2017-01-01
Visual coverage of surface elements of a small-body object requires multiple images to be taken that meet many requirements on their viewing angles, illumination angles, times of day, and combinations thereof. Designing trajectories capable of maximizing total possible coverage may not be useful since the image target sequence and the feasibility of said sequence given the rotation-rate limitations of the spacecraft are not taken into account. This work presents a means of optimizing, in a multi-objective manner, surface target sequences that account for such limitations.
Can Linear Superiorization Be Useful for Linear Optimization Problems?
Censor, Yair
2017-01-01
Linear superiorization considers linear programming problems but instead of attempting to solve them with linear optimization methods it employs perturbation resilient feasibility-seeking algorithms and steers them toward reduced (not necessarily minimal) target function values. The two questions that we set out to explore experimentally are (i) Does linear superiorization provide a feasible point whose linear target function value is lower than that obtained by running the same feasibility-seeking algorithm without superiorization under identical conditions? and (ii) How does linear superiorization fare in comparison with the Simplex method for solving linear programming problems? Based on our computational experiments presented here, the answers to these two questions are: “yes” and “very well”, respectively. PMID:29335660
Cho, Hyunyi; Hall, Jennifer G.; Kosmoski, Carin; Fox, Rebekah L.; Mastin, Teresa
2008-01-01
The majority of tanning bed users in the U.S. are women. Previous health communication research frequently focused on the risk of skin cancer, but few studies assessed the mediated communication environment that may surround women’s beliefs and behaviors relevant to tanning. A content analysis of articles in eight magazines targeting girls, young women, older women, and women who are interested in fitness during the ten-year period of 1997–2006 was conducted. The amount of coverage of tanning bed use consequences was less than 50% of the coverage of tanning benefits. About 40% of the tanning benefits coverage touted looking healthy. The coverage of prevention methods focused on sunscreen use (55%), while the more important methods (e.g., protective clothing use) were rarely featured. Longitudinally, the coverage of the risk and prevention relevant issues increased between 1997 and 2006. The data indicate that the coverage of tanning benefits also increased during the same period. PMID:20228954
Worrall, Eve; Hill, Jenny; Webster, Jayne; Mortimer, Julia
2005-01-01
Widespread coverage of vulnerable populations with insecticide-treated nets (ITNs) constitutes an important component of the Roll Back Malaria (RBM) strategy to control malaria. The Abuja Targets call for 60% coverage of children under 5 years of age and pregnant women by 2005; but current coverage in Africa is unacceptably low. The RBM 'Strategic Framework for Coordinated National Action in Scaling-up Insecticide-Treated Netting Programmes in Africa' promotes coordinated national action and advocates sustained public provision of targeted subsidies to maximise public health benefits, alongside support and stimulation of the private sector. Several countries have already planned or initiated targeted subsidy schemes either on a pilot scale or on a national scale, and have valuable experience which can inform future interventions. The WHO RBM 'Workshop on mapping models for delivering ITNs through targeted subsidies' held in Zambia in 2003 provided an opportunity to share and document these country experiences. This paper brings together experiences presented at the workshop with other information on experiences of targeting subsidies on ITNs, net treatment kits and retreatment services (ITN products) in order to describe alternative approaches, highlight their similarities and differences, outline lessons learnt, and identify gaps in knowledge. We find that while there is a growing body of knowledge on different approaches to targeting ITN subsidies, there are significant gaps in knowledge in crucial areas. Key questions regarding how best to target, how much it will cost and what outcomes (levels of coverage) to expect remain unanswered. High quality, well-funded monitoring and evaluation of alternative approaches to targeting ITN subsidies is vital to develop a knowledge base so that countries can design and implement effective strategies to target ITN subsidies.
Cordova, J. Scott; Kandula, Shravan; Gurbani, Saumya; Zhong, Jim; Tejani, Mital; Kayode, Oluwatosin; Patel, Kirtesh; Prabhu, Roshan; Schreibmann, Eduard; Crocker, Ian; Holder, Chad A.; Shim, Hyunsuk; Shu, Hui-Kuo
2017-01-01
Due to glioblastoma’s infiltrative nature, an optimal radiation therapy (RT) plan requires targeting infiltration not identified by anatomical magnetic resonance imaging (MRI). Here, high-resolution, whole-brain spectroscopic MRI (sMRI) is used to describe tumor infiltration alongside anatomical MRI and simulate the degree to which it modifies RT target planning. In 11 patients with glioblastoma, data from preRT sMRI scans were processed to give high-resolution, whole-brain metabolite maps normalized by contralateral white matter. Maps depicting choline to N-Acetylaspartate (Cho/NAA) ratios were registered to contrast-enhanced T1-weighted RT planning MRI for each patient. Volumes depicting metabolic abnormalities (1.5−, 1.75−, and 2.0-fold increases in Cho/NAA ratios) were compared with conventional target volumes and contrast-enhancing tumor at recurrence. sMRI-modified RT plans were generated to evaluate target volume coverage and organ-at-risk dose constraints. Conventional clinical target volumes and Cho/NAA abnormalities identified significantly different regions of microscopic infiltration with substantial Cho/NAA abnormalities falling outside of the conventional 60 Gy isodose line (41.1, 22.2, and 12.7 cm3, respectively). Clinical target volumes using Cho/NAA thresholds exhibited significantly higher coverage of contrast enhancement at recurrence on average (92.4%, 90.5%, and 88.6%, respectively) than conventional plans (82.5%). sMRI-based plans targeting tumor infiltration met planning objectives in all cases with no significant change in target coverage. In 2 cases, the sMRI-modified plan exhibited better coverage of contrast-enhancing tumor at recurrence than the original plan. Integration of the high-resolution, whole-brain sMRI into RT planning is feasible, resulting in RT target volumes that can effectively target tumor infiltration while adhering to conventional constraints. PMID:28105468
USDA-ARS?s Scientific Manuscript database
The ultimate goal of a pesticide spraying system is to provide adequate coverage on intended canopies with a minimum amount of spray materials and off-target waste. Better spray coverage requires an understanding of the fate and transport of spray droplets carried by turbulent airflows in orchards. ...
DOE Office of Scientific and Technical Information (OSTI.GOV)
An, Y; Bues, M; Schild, S
Purpose: We propose to apply a robust optimization model based on fuzzy-logic constraints in the intensity-modulated proton therapy (IMPT) planning subject to range and patient setup uncertainties. The purpose is to ensure the plan robustness under uncertainty and obtain the best trade-off between tumor dose coverage and organ-at-risk(OAR) sparing. Methods: Two IMPT plans were generated for 3 head-and-neck cancer patients: one used the planning target volume(PTV) method; the other used the fuzzy robust optimization method. In the latter method, nine dose distributions were computed - the nominal one and one each for ±3mm setup uncertainties along three cardinal axes andmore » for ±3.5% range uncertainty. For tumors, these nine dose distributions were explicitly controlled by adding hard constraints with adjustable parameters. For OARs, fuzzy constraints that allow the dose to vary within a certain range were used so that the tumor dose distribution was guaranteed by minimum compromise of that of OARs. We rendered this model tractable by converting the fuzzy constraints to linear constraints. The plan quality was evaluated using dose-volume histogram(DVH) indices such as tumor dose coverage(D95%), homogeneity(D5%-D95%), plan robustness(DVH band at D95%), and OAR sparing like D1% of brain and D1% of brainstem. Results: Our model could yield clinically acceptable plans. The fuzzy-logic robust optimization method produced IMPT plans with comparable target dose coverage and homogeneity compared to the PTV method(unit: Gy[RBE]; average[min, max])(CTV D95%: 59 [52.7, 63.5] vs 53.5[46.4, 60.1], CTV D5% - D95%: 11.1[5.3, 18.6] vs 14.4[9.2, 21.5]). It also generated more robust plans(CTV DVH band at D95%: 3.8[1.2, 5.6] vs 11.5[6.2, 16.7]). The parameters of tumor constraints could be adjusted to control the tradeoff between tumor coverage and OAR sparing. Conclusion: The fuzzy-logic robust optimization generates superior IMPT with minimum compromise of OAR sparing. This research was supported by the National Cancer Institute Career Developmental Award K25CA168984, by the Fraternal Order of Eagles Cancer Research Fund Career Development Award, by The Lawrence W. and Marilyn W. Matteson Fund for Cancer Research, by Mayo Arizona State University Seed Grant, and by The Kemper Marley Foundation. eRA Person ID(s) for the Principal Investigator: 11017970 (Research Supported by National Institutes of Health)« less
Goswami, Jyotirup; Patra, Niladri B.; Sarkar, Biplab; Basu, Ayan; Pal, Santanu
2013-01-01
Background and Purpose: Conventional portals, based on bony anatomy, for external beam radiotherapy for cervical cancer have been repeatedly demonstrated as inadequate. Conversely, with image-based conformal radiotherapy, better target coverage may be offset by the greater toxicities and poorer compliance associated with treating larger volumes. This study was meant to dosimetrically compare conformal and conventional radiotherapy. Materials and Methods: Five patients of carcinoma cervix underwent planning CT scan with IV contrast and targets, and organs at risk (OAR) were contoured. Two sets of plans-conventional and conformal were generated for each patient. Field sizes were recorded, and dose volume histograms of both sets of plans were generated and compared on the basis of target coverage and OAR sparing. Results: Target coverage was significantly improved with conformal plans though field sizes required were significantly larger. On the other hand, dose homogeneity was not significantly improved. Doses to the OARs (rectum, urinary bladder, and small bowel) were not significantly different across the 2 arms. Conclusion: Three-dimensional conformal radiotherapy gives significantly better target coverage, which may translate into better local control and survival. On the other hand, it also requires significantly larger field sizes though doses to the OARs are not significantly increased. PMID:24455584
Leyvraz, Magali; Wirth, James P; Woodruff, Bradley A; Sankar, Rajan; Sodani, Prahlad R; Sharma, Narottam D; Aaron, Grant J
2016-01-01
The Integrated Child Development Services (ICDS) in the State of Telangana, India, freely provides a fortified complementary food product, Bal Amrutham, as a take-home ration to children 6-35 months of age. In order to understand the potential for impact of any intervention, it is essential to assess coverage and utilization of the program and to address the barriers to its coverage and utilization. A two-stage, stratified cross-sectional cluster survey was conducted to estimate the coverage and utilization of Bal Amrutham and to identify their barriers and drivers. In randomly selected catchment areas of ICDS centers, children under 36 months of age were randomly selected. A questionnaire, constructed from different validated and standard modules and designed to collect coverage data on nutrition programs, was administered to caregivers. A total of 1,077 children were enrolled in the survey. The coverage of the fortified take-home ration was found to be high among the target population. Nearly all caregivers (93.7%) had heard of Bal Amrutham and 86.8% had already received the product for the target child. Among the children surveyed, 57.2% consumed the product regularly. The ICDS program's services were not found to be a barrier to product coverage. In fact, the ICDS program was found to be widely available, accessible, accepted, and utilized by the population in both urban and rural catchment areas, as well as among poor and non-poor households. However, two barriers to optimal coverage were found: the irregular supply of the product to the beneficiaries and the intra-household sharing of the product. Although sharing was common, the product was estimated to provide the target children with significant proportions of the daily requirements of macro- and micronutrients. Bal Amrutham is widely available, accepted, and consumed among the target population in the catchment areas of ICDS centers. The coverage of the product could be further increased by improving the supply chain.
Arbyn, Marc; Simoens, Cindy; Van Oyen, Herman; Foidart, Jean-Michel; Goffin, Frédéric; Simon, Philippe; Fabri, Valérie
2009-05-01
Cervical cancer screening by surveys overestimate coverage because of selection and reporting biases. The prepared Inter-Mutualistic Agency dataset has about 13 million records from Pap smears, colposcopies, cervical biopsies and surgery, performed in Belgium between 1996 and 2000. Cervical cancer screening coverage was defined as the proportion of the target population (women of 25-64 years) that has had a Pap smear taken within the last 3 years. Proportions and incidence rates were computed using official population data of the corresponding age group, area and calendar year. Cervical cancer screening coverage, in the period 1998-2000, was 59% at national level, for the target age group 25-64 years. Differences were small between the 3 regions. Variation ranged from 39% to 71%. Coverage was 64% for 25-29 year old women, 67% for those aged 30-39 years, 56% for those aged 50-54. The modal screening interval was 1 year. In the 3-year period 1998-2000, 3 million smears were taken from the 2.7 million women in the age group 25-64. Only 1.6 million women of the target group got one or more smears in that period and 1.1 million women had no smears, corresponding to an average of 1.88 smears per woman. Coverage reached only 59%, but the number of smears used was sufficient to cover more than 100% of the target population. Structural reduction of overuse and extension of coverage is warranted.
Evans, J; Chen, Q; Wuthrick, E; Weldon, M; Rong, Y
2012-06-01
Several planning strategies are available for hippocampal- avoidance whole-brain radiotherapy (HA-WBRT) following RTOG protocol 0933, but have yet to be compared on a common set of patient data. In this inter-institutional investigation, we evaluate three modalities likely to be employed by protocol participants; step-and-shoot IMRT, volumetric modulated arc therapy, and helical tomotherapy. A common set of patients is used for comparison, including credentialing and successfully accrued patients. Eight patient datasets were selected and de-identified prior to planning. Structures were contoured by physicians per protocol using fused MRI datasets. Three plans were generated for each dataset: Philips Pinnacle 9-field non-coplanar IMRT using protocol recommended beam parameters, Varian's RapidArc using two coplanar arcs, and Accuray's TomoTherapy using a 1cm jaw width. With the goal of meeting the compliance criteria outlined in RTOG 0933 (target coverage and dose limits to the hippocampus and optic structures), three planners independently planned each modality without prior knowledge of the patient's other plans to reduce bias. The three plans for each patient were compared according to the protocol's dosimetric compliance criteria. A homogeneity index was also computed to compare target dose uniformity. All plans achieved the protocol dose criteria, except for one RapidArc plan with slightly inferior dose to the optic chiasm. TomoTherapy offered superior dose homogeneity for all patients. For the two linac based methods, RapidArc was found to provide dose homogeneity at least as good as, and in most cases superior to, 9-field step-and-shoot IMRT. Helical TomoTherapy offers superior dose homogeneity for HA-WBRT following RTOG 0933. Compared to step-and-shoot IMRT, volumetric modulated arc techniques, such as RapidArc, can offer improved homogeneity for HA- WBRT and are generally more efficient/expeditious to deliver than the noncoplanar 9-field arrangement recommended by the protocol, which uses 7 separate couch angles. © 2012 American Association of Physicists in Medicine.
Oral Cholera Vaccine Coverage during an Outbreak and Humanitarian Crisis, Iraq, 2015.
Lam, Eugene; Al-Tamimi, Wasan; Russell, Steven Paul; Butt, Muhammad Obaid-Ul Islam; Blanton, Curtis; Musani, Altaf Sadrudin; Date, Kashmira
2017-01-01
During November-December 2015, as part of the 2015 cholera outbreak response in Iraq, the Iraqi Ministry of Health targeted ≈255,000 displaced persons >1 year of age with 2 doses of oral cholera vaccine (OCV). All persons who received vaccines were living in selected refugee camps, internally displaced persons camps, and collective centers. We conducted a multistage cluster survey to obtain OCV coverage estimates in 10 governorates that were targeted during the campaign. In total, 1,226 household and 5,007 individual interviews were conducted. Overall, 2-dose OCV coverage in the targeted camps was 87% (95% CI 85%-89%). Two-dose OCV coverage in the 3 northern governorates (91%; 95% CI 87%-94%) was higher than that in the 7 southern and central governorates (80%; 95% CI 77%-82%). The experience in Iraq demonstrates that OCV campaigns can be successfully implemented as part of a comprehensive response to cholera outbreaks among high-risk populations in conflict settings.
2016-01-01
This study quantified the interplay and gradient effects on GTV dose coverage for 3D CRT, dMLC IMRT, and VMAT SABR treatments for target amplitudes of 5–30 mm using 3DVH v3.1 software incorporating 4D Respiratory MotionSim (4D RMS) module. For clinically relevant motion periods (5 s), the interplay effect was small, with deviations in the minimum dose covering the target volume (D99%) of less than ±2.5% for target amplitudes up to 30 mm. Increasing the period to 60 s resulted in interplay effects of up to ±15.0% on target D99% dose coverage. The gradient effect introduced by target motion resulted in deviations of up to ±3.5% in D99% target dose coverage. VMAT treatments showed the largest deviation in dose metrics, which was attributed to the long delivery times in comparison to dMLC IMRT. Retrospective patient analysis indicated minimal interplay and gradient effects for patients treated with dMLC IMRT at the NCCI. PACS numbers: 87.55.km, 87.56.Fc PMID:26894347
Managing Access: Extending Medicaid to Children Through School-Based HMO Coverage
Coulam, Robert F.; Irvin, Carol V.; Calore, Kathleen A.; Kidder, David E.; Rosenbach, Margo L.
1997-01-01
This study explores how a health maintenance organization's (HMO) capacity and incentives to manage care might be used to improve access. In the early 1990s, the Florida Healthy Kids (FHK) demonstration extended Medicaid-like HMO coverage to indigent children in the public schools of Volusia County, Florida. The study finds that uninsured student months in area public schools were likely reduced by one-half. Utilization and cost levels for these indigent enrollees proved to be indistinguishable from commercial clients; and measures of access, utilization, and satisfaction for enrollees were in line with (and in some cases, superior to) non-enrollees with private insurance. Overall, these results suggest the value of using schools as a medium for providing coverage, and the importance of taking deliberate steps to manage access to reduce non-financial barriers to care. PMID:10170346
Formal methods for test case generation
NASA Technical Reports Server (NTRS)
Rushby, John (Inventor); De Moura, Leonardo Mendonga (Inventor); Hamon, Gregoire (Inventor)
2011-01-01
The invention relates to the use of model checkers to generate efficient test sets for hardware and software systems. The method provides for extending existing tests to reach new coverage targets; searching *to* some or all of the uncovered targets in parallel; searching in parallel *from* some or all of the states reached in previous tests; and slicing the model relative to the current set of coverage targets. The invention provides efficient test case generation and test set formation. Deep regions of the state space can be reached within allotted time and memory. The approach has been applied to use of the model checkers of SRI's SAL system and to model-based designs developed in Stateflow. Stateflow models achieving complete state and transition coverage in a single test case are reported.
Evaluation of target coverage and margins adequacy during CyberKnife Lung Optimized Treatment.
Ricotti, Rosalinda; Seregni, Matteo; Ciardo, Delia; Vigorito, Sabrina; Rondi, Elena; Piperno, Gaia; Ferrari, Annamaria; Zerella, Maria Alessia; Arculeo, Simona; Francia, Claudia Maria; Sibio, Daniela; Cattani, Federica; De Marinis, Filippo; Spaggiari, Lorenzo; Orecchia, Roberto; Riboldi, Marco; Baroni, Guido; Jereczek-Fossa, Barbara Alicja
2018-04-01
Evaluation of target coverage and verification of safety margins, in motion management strategies implemented by Lung Optimized Treatment (LOT) module in CyberKnife system. Three fiducial-less motion management strategies provided by LOT can be selected according to tumor visibility in the X ray images acquired during treatment. In 2-view modality the tumor is visible in both X ray images and full motion tracking is performed. In 1-view modality the tumor is visible in a single X ray image, therefore, motion tracking is combined with an internal target volume (ITV)-based margin expansion. In 0-view modality the lesion is not visible, consequently the treatment relies entirely on an ITV-based approach. Data from 30 patients treated in 2-view modality were selected providing information on the three-dimensional tumor motion in correspondence to each X ray image. Treatments in 1-view and 0-view modalities were simulated by processing log files and planning volumes. Planning target volume (PTV) margins were defined according to the tracking modality: end-exhale clinical target volume (CTV) + 3 mm in 2-view and ITV + 5 mm in 0-view. In the 1-view scenario, the ITV encompasses only tumor motion along the non-visible direction. Then, non-uniform ITV to PTV margins were applied: 3 mm and 5 mm in the visible and non-visible direction, respectively. We defined the coverage of each voxel of the CTV as the percentage of X ray images where such voxel was included in the PTV. In 2-view modality coverage was calculated as the intersection between the CTV centred on the imaged target position and the PTV centred on the predicted target position, as recorded in log files. In 1-view modality, coverage was calculated as the intersection between the CTV centred on the imaged target position and the PTV centred on the projected predictor data. In 0-view modality coverage was calculated as the intersection between the CTV centred on the imaged target position and the non-moving PTV. Similar to dose-volume histogram, CTV coverage-volume histograms (defined as CVH) were derived for each patient and treatment modality. The geometric coverages of the 90% and 95% of CTV volume (C90, C95, respectively) were evaluated. Patient-specific optimal margins (ensuring C95 ≥ 95%) were computed retrospectively. The median ± interquartile-rage of C90 and C95 for upper lobe lesions was 99.1 ± 0.6% and 99.0 ± 3.1%, whereas they were 98.9 ± 4.2% and 97.8 ± 7.5% for lower and middle lobe tumors. In 2-view, 1-view and 0-view modality, adopted margins ensured C95 ≥ 95% in 70%, 85% and 63% of cases and C95 ≥ 90% in 90%, 88% and 83% of cases, respectively. In 2-view, 1-view and 0-view a reduction in margins still ensured C95 ≥ 95% in 33%, 78% and 59% of cases, respectively. CTV coverage analysis provided an a-posteriori evaluation of the treatment geometric accuracy and allowed a quantitative verification of the adequacy of the PTV margins applied in CyberKnife LOT treatments offering guidance in the selection of CTV margins. © 2018 American Association of Physicists in Medicine.
To Market, To Market: How to Make the Most of an Institution's Risk Financing.
ERIC Educational Resources Information Center
Noel, Richard H.
1996-01-01
Discusses how higher education institutions can market their risk financing program to insurance brokers and insurance companies to obtain superior, cost effective coverage in the current buyer's market. Explains the development of a marketing package, the negotiating process, and the selection of brokers and insurance companies. (MDM)
It Never Hurts To Go Back and Remind Ourselves about the Basics in Newspaper Journalism.
ERIC Educational Resources Information Center
Konkle, Bruce E.
2002-01-01
Suggests knowing the basics is critical if newspaper advisers and staffs are to move their newspaper into the best, excellent, superior, above average, all-everything category a scholastic press evaluation service may award. Discusses the basic areas of writing, design, photojournalism, advertising, and overall coverage. (RS)
Rahman, Md Shafiur; Rahman, Md Mizanur; Gilmour, Stuart; Swe, Khin Thet; Krull Abe, Sarah; Shibuya, Kenji
2018-01-01
Many countries are implementing health system reforms to achieve universal health coverage (UHC) by 2030. To understand the progress towards UHC in Bangladesh, we estimated trends in indicators of the health service and of financial risk protection. We also estimated the probability of Bangladesh's achieving of UHC targets of 80% essential health-service coverage and 100% financial risk protection by 2030. We estimated the coverage of UHC indicators-13 prevention indicators and four treatment indicators-from 19 nationally representative population-based household surveys done in Bangladesh from Jan 1, 1991, to Dec 31, 2014. We used a Bayesian regression model to estimate the trend and to predict the coverage of UHC indicators along with the probabilities of achieving UHC targets of 80% coverage of health services and 100% coverage of financial risk protection from catastrophic and impoverishing health payments by 2030. We used the concentration index and relative index of inequality to assess wealth-based inequality in UHC indicators. If the current trends remain unchanged, we estimated that coverage of childhood vaccinations, improved water, oral rehydration treatment, satisfaction with family planning, and non-use of tobacco will achieve the 80% target by 2030. However, coverage of four antenatal care visits, facility-based delivery, skilled birth attendance, postnatal checkups, care seeking for pneumonia, exclusive breastfeeding, non-overweight, and adequate sanitation were not projected to achieve the target. Quintile-specific projections showed wide wealth-based inequality in access to antenatal care, postnatal care, delivery care, adequate sanitation, and care seeking for pneumonia, and this inequality was projected to continue for all indicators. The incidence of catastrophic health expenditure and impoverishment were projected to increase from 17% and 4%, respectively, in 2015, to 20% and 9%, respectively, by 2030. Inequality analysis suggested that wealthiest households would disproportionately face more financial catastrophe than the most disadvantaged households. Despite progress, Bangladesh will not achieve the 2030 UHC targets unless the country scales up interventions related to maternal and child health services, and reforms health financing systems to avoid high dependency on out-of-pocket payments. The introduction of a national health insurance system, increased public funding for health care, and expansion of community-based clinics in rural areas could help to move the country towards UHC. Japan Ministry of Health, Labour, and Welfare. Copyright © 2018 The Author(s). Published by Elsevier Ltd. This is an Open Access article under the CC BY-NC-ND 4.0 license. Published by Elsevier Ltd.. All rights reserved.
Massat, Nathalie J; Douglas, Elaine; Waller, Jo; Wardle, Jane; Duffy, Stephen W
2015-01-01
Objectives Reducing cancer screening inequalities in England is a major focus of the 2011 Department of Health cancer outcome strategy. Screening coverage requires regular monitoring in order to implement targeted interventions where coverage is low. This study aimed to characterise districts with atypical coverage levels for cervical or breast screening. Design Observational study of district-level coverage in the English Cervical and Breast screening programmes in 2012. Setting England, UK. Participants All English women invited to participate in the cervical (age group 25–49 and 50–64) and breast (age group 50–64) screening programmes. Outcomes Risk adjustment models for coverage were developed based on district-level characteristics. Funnel plots of adjusted coverage were constructed, and atypical districts examined by correlation analysis. Results Variability in coverage was primarily explained by population factors, whereas general practice characteristics had little independent effect. Deprivation and ethnicity other than white, Asian, black or mixed were independently associated with poorer coverage in both screening programmes, with ethnicity having the strongest effect; by comparison, the influence of Asian, black or mixed ethnic minority was limited. Deprivation, ethnicity and urbanisation largely accounted for the lower cervical screening coverage in London. However, for breast screening, being located in London remained a strong negative predictor. A subset of districts was identified as having atypical coverage across programmes. Correlates of deprivation in districts with relatively low adjusted coverage were substantially different from overall correlates of deprivation. Discussion These results inform the continuing drive to reduce avoidable cancer deaths in England, and encourage implementation of targeted interventions in communities residing in districts identified as having atypically low coverage. Sequential implementation to monitor the impact of local interventions would help accrue evidence on ‘what works’. PMID:26209119
The influence of working memory on the anger superiority effect.
Moriya, Jun; Koster, Ernst H W; De Raedt, Rudi
2014-01-01
The anger superiority effect shows that an angry face is detected more efficiently than a happy face. However, it is still controversial whether attentional allocation to angry faces is a bottom-up process or not. We investigated whether the anger superiority effect is influenced by top-down control, especially working memory (WM). Participants remembered a colour and then searched for differently coloured facial expressions. Just holding the colour information in WM did not modulate the anger superiority effect. However, when increasing the probabilities of trials in which the colour of a target face matched the colour held in WM, participants were inclined to direct attention to the target face regardless of the facial expression. Moreover, the knowledge of high probability of valid trials eliminated the anger superiority effect. These results suggest that the anger superiority effect is modulated by top-down effects of WM, the probability of events and expectancy about these probabilities.
Ogbuanu, Ikechukwu U.; Adegoke, Oluwasegun J.; Scobie, Heather M.; Uba, Belinda V.; Wannemuehler, Kathleen A.; Ruiz, Alicia; Elmousaad, Hashim; Ohuabunwo, Chima J.; Mustafa, Mahmud; Nguku, Patrick; Waziri, Ndadilnasiya Endie; Vertefeuille, John F.
2016-01-01
Background Despite recent success towards controlling poliovirus transmission, Nigeria has struggled to achieve uniformly high routine vaccination coverage. A lack of reliable vaccination coverage data at the operational level makes it challenging to target program improvement. To reliably estimate vaccination coverage, we conducted district-level vaccine coverage surveys using a pre-existing infrastructure of polio technical staff in northern Nigeria. Methods Household-level cluster surveys were conducted in 40 polio high risk districts of Nigeria during 2014–2015. Global positioning system technology and intensive supervision by a pool of qualified technical staff were used to ensure high survey quality. Vaccination status of children aged 12–23 months was documented based on vaccination card or caretaker’s recall. District-level coverage estimates were calculated using survey methods. Results Data from 7,815 children across 40 districts were analyzed. District-level coverage with the third dose of diphtheria-pertussis-tetanus vaccine (DPT3) ranged widely from 1–63%, with all districts having DPT3 coverage below the target of 80%. Median coverage across all districts for each of eight vaccine doses (1 Bacille Calmette-Guérin dose, 3 DPT doses, 3 oral poliovirus vaccine doses, and 1 measles vaccine dose) was <50%. DPT3 coverage by survey was substantially lower (range: 28%–139%) than the 2013 administrative coverage reported among children aged <12 months. Common reported reasons for non-vaccination included lack of knowledge about vaccines and vaccination services (50%) and factors related to access to routine immunization services (15%). Conclusions Survey results highlighted vaccine coverage gaps that were systematically underestimated by administrative reporting across 40 polio high risk districts in northern Nigeria. Given the limitations of administrative coverage data, our approach to conducting quality district-level coverage surveys and providing data to assess and remediate issues contributing to poor vaccination coverage could serve as an example in countries with sub-optimal vaccination coverage, similar to Nigeria. PMID:27936077
Gunnala, Rajni; Ogbuanu, Ikechukwu U; Adegoke, Oluwasegun J; Scobie, Heather M; Uba, Belinda V; Wannemuehler, Kathleen A; Ruiz, Alicia; Elmousaad, Hashim; Ohuabunwo, Chima J; Mustafa, Mahmud; Nguku, Patrick; Waziri, Ndadilnasiya Endie; Vertefeuille, John F
2016-01-01
Despite recent success towards controlling poliovirus transmission, Nigeria has struggled to achieve uniformly high routine vaccination coverage. A lack of reliable vaccination coverage data at the operational level makes it challenging to target program improvement. To reliably estimate vaccination coverage, we conducted district-level vaccine coverage surveys using a pre-existing infrastructure of polio technical staff in northern Nigeria. Household-level cluster surveys were conducted in 40 polio high risk districts of Nigeria during 2014-2015. Global positioning system technology and intensive supervision by a pool of qualified technical staff were used to ensure high survey quality. Vaccination status of children aged 12-23 months was documented based on vaccination card or caretaker's recall. District-level coverage estimates were calculated using survey methods. Data from 7,815 children across 40 districts were analyzed. District-level coverage with the third dose of diphtheria-pertussis-tetanus vaccine (DPT3) ranged widely from 1-63%, with all districts having DPT3 coverage below the target of 80%. Median coverage across all districts for each of eight vaccine doses (1 Bacille Calmette-Guérin dose, 3 DPT doses, 3 oral poliovirus vaccine doses, and 1 measles vaccine dose) was <50%. DPT3 coverage by survey was substantially lower (range: 28%-139%) than the 2013 administrative coverage reported among children aged <12 months. Common reported reasons for non-vaccination included lack of knowledge about vaccines and vaccination services (50%) and factors related to access to routine immunization services (15%). Survey results highlighted vaccine coverage gaps that were systematically underestimated by administrative reporting across 40 polio high risk districts in northern Nigeria. Given the limitations of administrative coverage data, our approach to conducting quality district-level coverage surveys and providing data to assess and remediate issues contributing to poor vaccination coverage could serve as an example in countries with sub-optimal vaccination coverage, similar to Nigeria.
Change-Based Satellite Monitoring Using Broad Coverage and Targetable Sensing
NASA Technical Reports Server (NTRS)
Chien, Steve A.; Tran, Daniel Q.; Doubleday, Joshua R.; Doggett, Thomas
2013-01-01
A generic software framework analyzes data from broad coverage sweeps or general larger areas of interest. Change detection methods are used to extract subsets of directed swath areas that intersect areas of change. These areas are prioritized and allocated to targetable assets. This method is deployed in an automatic fashion, and has operated without human monitoring or intervention for sustained periods of time (months).
Moseley, Douglas; Kassam, Zahra; Kim, Sun Mo; Cho, Charles
2013-01-01
Recently, volumetric‐modulated arc therapy (VMAT) has demonstrated the ability to deliver radiation dose precisely and accurately with a shorter delivery time compared to conventional intensity‐modulated fixed‐field treatment (IMRT). We applied the hypothesis of VMAT technique for the treatment of thoracic esophageal carcinoma to determine superior or equivalent conformal dose coverage for a large thoracic esophageal planning target volume (PTV) with superior or equivalent sparing of organs‐at‐risk (OARs) doses, and reduce delivery time and monitor units (MUs), in comparison with conventional fixed‐field IMRT plans. We also analyzed and compared some other important metrics of treatment planning and treatment delivery for both IMRT and VMAT techniques. These metrics include: 1) the integral dose and the volume receiving intermediate dose levels between IMRT and VMATI plans; 2) the use of 4D CT to determine the internal motion margin; and 3) evaluating the dosimetry of every plan through patient‐specific QA. These factors may impact the overall treatment plan quality and outcomes from the individual planning technique used. In this study, we also examined the significance of using two arcs vs. a single‐arc VMAT technique for PTV coverage, OARs doses, monitor units and delivery time. Thirteen patients, stage T2‐T3 N0‐N1 (TNM AJCC 7th edn.), PTV volume median 395 cc (range 281–601 cc), median age 69 years (range 53 to 85), were treated from July 2010 to June 2011 with a four‐field (n=4) or five‐field (n=9) step‐and‐shoot IMRT technique using a 6 MV beam to a prescribed dose of 50 Gy in 20 to 25 F. These patients were retrospectively replanned using single arc (VMATI, 91 control points) and two arcs (VMATII, 182 control points). All treatment plans of the 13 study cases were evaluated using various dose‐volume metrics. These included PTV D99, PTV D95, PTV V9547.5Gy(95%), PTV mean dose, Dmax, PTV dose conformity (Van't Riet conformation number (CN)), mean lung dose, lung V20 and V5, liver V30, and Dmax to the spinal canal prv3mm. Also examined were the total plan monitor units (MUs) and the beam delivery time. Equivalent target coverage was observed with both VMAT single and two‐arc plans. The comparison of VMATI with fixed‐field IMRT demonstrated equivalent target coverage; statistically no significant difference were found in PTV D99 (p=0.47), PTV mean (p=0.12), PTV D95 and PTV V9547.5Gy (95%) (p=0.38). However, Dmax in VMATI plans was significantly lower compared to IMRT (p=0.02). The Van't Riet dose conformation number (CN) was also statistically in favor of VMATI plans (p=0.04). VMATI achieved lower lung V20 (p=0.05), whereas lung V5 (p=0.35) and mean lung dose (p=0.62) were not significantly different. The other OARs, including spinal canal, liver, heart, and kidneys showed no statistically significant differences between the two techniques. Treatment time delivery for VMATI plans was reduced by up to 55% (p=5.8E−10) and MUs reduced by up to 16% (p=0.001). Integral dose was not statistically different between the two planning techniques (p=0.99). There were no statistically significant differences found in dose distribution of the two VMAT techniques (VMATI vs. VMATII) Dose statistics for both VMAT techniques were: PTV D99 (p=0.76), PTV D95 (p=0.95), mean PTV dose (p=0.78), conformation number (CN) (p=0.26), and MUs (p=0.1). However, the treatment delivery time for VMATII increased significantly by two‐fold (p=3.0E−11) compared to VMATI. VMAT‐based treatment planning is safe and deliverable for patients with thoracic esophageal cancer with similar planning goals, when compared to standard IMRT. The key benefit for VMATI was the reduction in treatment delivery time and MUs, and improvement in dose conformality. In our study, we found no significant difference in VMATII over single‐arc VMATI for PTV coverage or OARs doses. However, we observed significant increase in delivery time for VMATII compared to VMATI. PACS number: 87.53.Kn, 87.55.‐x PMID:23652258
TU-AB-BRB-00: New Methods to Ensure Target Coverage
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
2015-06-15
The accepted clinical method to accommodate targeting uncertainties inherent in fractionated external beam radiation therapy is to utilize GTV-to-CTV and CTV-to-PTV margins during the planning process to design a PTV-conformal static dose distribution on the planning image set. Ideally, margins are selected to ensure a high (e.g. >95%) target coverage probability (CP) in spite of inherent inter- and intra-fractional positional variations, tissue motions, and initial contouring uncertainties. Robust optimization techniques, also known as probabilistic treatment planning techniques, explicitly incorporate the dosimetric consequences of targeting uncertainties by including CP evaluation into the planning optimization process along with coverage-based planning objectives. Themore » treatment planner no longer needs to use PTV and/or PRV margins; instead robust optimization utilizes probability distributions of the underlying uncertainties in conjunction with CP-evaluation for the underlying CTVs and OARs to design an optimal treated volume. This symposium will describe CP-evaluation methods as well as various robust planning techniques including use of probability-weighted dose distributions, probability-weighted objective functions, and coverage optimized planning. Methods to compute and display the effect of uncertainties on dose distributions will be presented. The use of robust planning to accommodate inter-fractional setup uncertainties, organ deformation, and contouring uncertainties will be examined as will its use to accommodate intra-fractional organ motion. Clinical examples will be used to inter-compare robust and margin-based planning, highlighting advantages of robust-plans in terms of target and normal tissue coverage. Robust-planning limitations as uncertainties approach zero and as the number of treatment fractions becomes small will be presented, as well as the factors limiting clinical implementation of robust planning. Learning Objectives: To understand robust-planning as a clinical alternative to using margin-based planning. To understand conceptual differences between uncertainty and predictable motion. To understand fundamental limitations of the PTV concept that probabilistic planning can overcome. To understand the major contributing factors to target and normal tissue coverage probability. To understand the similarities and differences of various robust planning techniques To understand the benefits and limitations of robust planning techniques.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chau, Ricky; Teo, Peter; Kam, Michael
The aim of this study is to evaluate the deficiencies in target coverage and organ protection of 2-dimensional radiation therapy (2DRT) in the treatment of advanced T-stage (T3-4) nasopharyngeal carcinoma (NPC), and assess the extent of improvement that could be achieved with intensity modulated radiation therapy (IMRT), with special reference to of the dose to the planning organ-at-risk volume (PRV) of the brainstem and spinal cord. A dosimetric study was performed on 10 patients with advanced T-stage (T3-4 and N0-2) NPC. Computer tomography (CT) images of 2.5-mm slice thickness of the head and neck were acquired with the patient immobilizedmore » in semi-extended-head position. A 2D plan based on Ho's technique, and an IMRT plan based on a 7-coplanar portals arrangement, were established for each patient. 2DRT was planned with the field borders and shielding drawn on the simulator radiograph with reference to bony landmarks, digitized, and entered into a planning computer for reconstruction of the 3D dose distribution. The 2DRT and IMRT treatment plans were evaluated and compared with respect to the dose-volume histograms (DVHs) of the targets and the organs-at-risk (OARs), tumor control probability (TCP), and normal tissue complication probabilities (NTCPs). With IMRT, the dose coverage of the target was superior to that of 2DRT. The mean minimum dose of the GTV and PTV were increased from 33.7 Gy (2DRT) to 62.6 Gy (IMRT), and 11.9 Gy (2DRT) to 47.8 Gy (IMRT), respectively. The D{sub 95} of the GTV and PTV were also increased from 57.1 Gy (2DRT) to 67 Gy (IMRT), and 45 Gy (2DRT) to 63.6 Gy (IMRT), respectively. The TCP was substantially increased to 78.5% in IMRT. Better protection of the critical normal organs was also achieved with IMRT. The mean maximum dose delivered to the brainstem and spinal cord were reduced significantly from 61.8 Gy (2DRT) to 52.8 Gy (IMRT) and 56 Gy (2DRT) to 43.6 Gy (IMRT), respectively, which were within the conventional dose limits of 54 Gy for brainstem and of 45 Gy for spinal cord. The mean maximum doses deposited on the PRV of the brainstem and spinal cord were 60.7 Gy and 51.6 Gy respectively, which were above the conventional dose limits. For the chiasm, the mean dose maximum and the dose to 5% of its volume were reduced from 64.3 Gy (2DRT) to 53.7 Gy (IMRT) and from 62.8 Gy (2DRT) to 48.7 Gy (IMRT), respectively, and the corresponding NTCP was reduced from 18.4% to 2.1%. For the temporal lobes, the mean dose to 10% of its volume (about 4.6 cc) was reduced from 63.8 Gy (2DRT) to 55.4 Gy (IMRT) and the NTCP was decreased from 11.7% to 3.4%. The therapeutic ratio for T3-4 NPC tumors can be significantly improved with IMRT treatment technique due to improvement both in target coverage and the sparing of the critical normal organ. Although the maximum doses delivered to the brainstem and spinal cord in IMRT can be kept at or below their conventional dose limits, the maximum doses deposited on the PRV often exceed these limits due to the close proximity between the target and OARs. In other words, ideal dosimetric considerations cannot be fulfilled in IMRT planning for T3-4 NPC tumors. A compromise of the maximal dose limit to the PRV of the brainstem and spinal cord would need be accepted if dose coverage to the targets is not to be unacceptably compromised. Dosimetric comparison with 2DRT plans show that these dose limits to PRV were also frequently exceeded in 2DRT plans for locally advanced NPC. A dedicated retrospective study on the incidence of clinical injury to neurological organs in a large series of patients with T3-4 NPC treated by 2DRT may provide useful reference data in exploring how far the PRV dose constraints may be relaxed, to maximize the target coverage without compromising the normal organ function.« less
NASA Technical Reports Server (NTRS)
Rehder, J. B. (Principal Investigator)
1973-01-01
The author has identified the following significant results. ERTS-1 has proven to be an effective earth-orbiting monitor of landscape change. Its regional coverage for large areal monitoring has been effective for the detection and mapping of agricultural plowing regions, for general forest cover mapping, for flood mapping, for strip mine mapping, and for short-lived precipitation mapping patterns. Paramount to the entire study has been the temporal coverage provided by ERTS. Without the cyclic coverage on an 18 day basis, temporal coverage would have been inadequate for the detection and mapping of strip mining landscape change, the analysis of agricultural landscape change based on plowing patterns, the analysis of urban-suburban growth changes, and the mapping of the Mississippi River floods. Cost benefits from ERTS are unquestionably superior to aircraft systems in regard to large regional coverage and cyclic temporal parameters. For the analysis of landscape change in large regions such as statewide areas or even areas of 10,000 square miles, ERTS is of cost benefit consideration. Not only does the cost of imagery favor ERTS but the reduction of man-hours using ERTS has been in the magnitude of 1:10.
2012-01-01
Background To investigate geometric and dosimetric accuracy of frame-less image-guided radiosurgery (IG-RS) for brain metastases. Methods and materials Single fraction IG-RS was practiced in 72 patients with 98 brain metastases. Patient positioning and immobilization used either double- (n = 71) or single-layer (n = 27) thermoplastic masks. Pre-treatment set-up errors (n = 98) were evaluated with cone-beam CT (CBCT) based image-guidance (IG) and were corrected in six degrees of freedom without an action level. CBCT imaging after treatment measured intra-fractional errors (n = 64). Pre- and post-treatment errors were simulated in the treatment planning system and target coverage and dose conformity were evaluated. Three scenarios of 0 mm, 1 mm and 2 mm GTV-to-PTV (gross tumor volume, planning target volume) safety margins (SM) were simulated. Results Errors prior to IG were 3.9 mm ± 1.7 mm (3D vector) and the maximum rotational error was 1.7° ± 0.8° on average. The post-treatment 3D error was 0.9 mm ± 0.6 mm. No differences between double- and single-layer masks were observed. Intra-fractional errors were significantly correlated with the total treatment time with 0.7mm±0.5mm and 1.2mm±0.7mm for treatment times ≤23 minutes and >23 minutes (p<0.01), respectively. Simulation of RS without image-guidance reduced target coverage and conformity to 75% ± 19% and 60% ± 25% of planned values. Each 3D set-up error of 1 mm decreased target coverage and dose conformity by 6% and 10% on average, respectively, with a large inter-patient variability. Pre-treatment correction of translations only but not rotations did not affect target coverage and conformity. Post-treatment errors reduced target coverage by >5% in 14% of the patients. A 1 mm safety margin fully compensated intra-fractional patient motion. Conclusions IG-RS with online correction of translational errors achieves high geometric and dosimetric accuracy. Intra-fractional errors decrease target coverage and conformity unless compensated with appropriate safety margins. PMID:22531060
DOE Office of Scientific and Technical Information (OSTI.GOV)
Michalski, Andrea; Central Coast Cancer Centre, Gosford Hospital, Gosford, New South Wales; Atyeo, John, E-mail: john.atyeo@sydney.edu.au
2014-07-01
Radiation therapy to the breast is a complex task, with many different techniques that can be employed to ensure adequate dose target coverage while minimizing doses to the organs at risk. This study compares the dose planning outcomes of 3 radiation treatment modalities, 3 dimensional conformal radiation therapy (3D-CRT), intensity-modulated radiation therapy (IMRT), and static tomotherapy, for left-sided whole-breast radiation treatment with a simultaneous integrated boost (SIB). Overall, 20 patients with left-sided breast cancer were separated into 2 cohorts, small and large, based on breast volume. Dose plans were produced for each patient using 3D-CRT, IMRT, and static tomotherapy. Allmore » patients were prescribed a dose of 45 Gy in 20 fractions to the breast with an SIB of 56 Gy in 20 fractions to the tumor bed and normalized so that D{sub 98%} > 95% of the prescription dose. Dosimetric comparisons were made between the 3 modalities and the interaction of patient size. All 3 modalities offered adequate planning target volume (PTV) coverage with D{sub 98%} > 95% and D{sub 2%} < 107%. Static tomotherapy offered significantly improved (p = 0.006) dose homogeneity to the PTV{sub boost} {sub eval} (0.079 ± 0.011) and breast minus the SIB volume (Breast{sub SIB}) (p < 0.001, 0.15 ± 0.03) compared with the PTV{sub boost} {sub eval} (0.085 ± 0.008, 0.088 ± 0.12) and Breast{sub SIB} (0.22 ± 0.05, 0.23 ± 0.03) for IMRT and 3D-CRT, respectively. Static tomotherapy also offered statistically significant reductions (p < 0.001) in doses to the ipsilateral lung mean dose of 6.79 ± 2.11 Gy compared with 7.75 ± 2.54 Gy and 8.29 ± 2.76 Gy for IMRT and 3D-CRT, respectively, and significantly (p < 0.001) reduced heart doses (mean = 2.83 ± 1.26 Gy) compared to both IMRT and 3D-CRT (mean = 3.70 ± 1.44 Gy and 3.91 ± 1.58 Gy). Static tomotherapy is the dosimetrically superior modality for the whole breast with an SIB compared with IMRT and 3D-CRT. IMRT is superior to 3D-CRT in both PTV dose conformity and reduction of mean doses to the ipsilateral lung.« less
Mok, Henry; Crane, Christopher H; Palmer, Matthew B; Briere, Tina M; Beddar, Sam; Delclos, Marc E; Krishnan, Sunil; Das, Prajnan
2011-06-08
A strong dose-volume relationship exists between the amount of small bowel receiving low- to intermediate-doses of radiation and the rates of acute, severe gastrointestinal toxicity, principally diarrhea. There is considerable interest in the application of highly conformal treatment approaches, such as intensity-modulated radiation therapy (IMRT), to reduce dose to adjacent organs-at-risk in the treatment of carcinoma of the rectum. Therefore, we performed a comprehensive dosimetric evaluation of IMRT compared to 3-dimensional conformal radiation therapy (3DCRT) in standard, preoperative treatment for rectal cancer. Using RTOG consensus anorectal contouring guidelines, treatment volumes were generated for ten patients treated preoperatively at our institution for rectal carcinoma, with IMRT plans compared to plans derived from classic anatomic landmarks, as well as 3DCRT plans treating the RTOG consensus volume. The patients were all T3, were node-negative (N = 1) or node-positive (N = 9), and were planned to a total dose of 45-Gy. Pairwise comparisons were made between IMRT and 3DCRT plans with respect to dose-volume histogram parameters. IMRT plans had superior PTV coverage, dose homogeneity, and conformality in treatment of the gross disease and at-risk nodal volume, in comparison to 3DCRT. Additionally, in comparison to the 3DCRT plans, IMRT achieved a concomitant reduction in doses to the bowel (small bowel mean dose: 18.6-Gy IMRT versus 25.2-Gy 3DCRT; p = 0.005), bladder (V40Gy: 56.8% IMRT versus 75.4% 3DCRT; p = 0.005), pelvic bones (V40Gy: 47.0% IMRT versus 56.9% 3DCRT; p = 0.005), and femoral heads (V40Gy: 3.4% IMRT versus 9.1% 3DCRT; p = 0.005), with an improvement in absolute volumes of small bowel receiving dose levels known to induce clinically-relevant acute toxicity (small bowel V15Gy: 138-cc IMRT versus 157-cc 3DCRT; p = 0.005). We found that the IMRT treatment volumes were typically larger than that covered by classic bony landmark-derived fields, without incurring penalty with respect to adjacent organs-at-risk. For rectal carcinoma, IMRT, compared to 3DCRT, yielded plans superior with respect to target coverage, homogeneity, and conformality, while lowering dose to adjacent organs-at-risk. This is achieved despite treating larger volumes, raising the possibility of a clinically-relevant improvement in the therapeutic ratio through the use of IMRT with a belly-board apparatus.
Varela, Miguel A; Curtis, Helen J; Douglas, Andrew GL; Hammond, Suzan M; O'Loughlin, Aisling J; Sobrido, Maria J; Scholefield, Janine; Wood, Matthew JA
2016-01-01
Allele-specific gene therapy aims to silence expression of mutant alleles through targeting of disease-linked single-nucleotide polymorphisms (SNPs). However, SNP linkage to disease varies between populations, making such molecular therapies applicable only to a subset of patients. Moreover, not all SNPs have the molecular features necessary for potent gene silencing. Here we provide knowledge to allow the maximisation of patient coverage by building a comprehensive understanding of SNPs ranked according to their predicted suitability toward allele-specific silencing in 14 repeat expansion diseases: amyotrophic lateral sclerosis and frontotemporal dementia, dentatorubral-pallidoluysian atrophy, myotonic dystrophy 1, myotonic dystrophy 2, Huntington's disease and several spinocerebellar ataxias. Our systematic analysis of DNA sequence variation shows that most annotated SNPs are not suitable for potent allele-specific silencing across populations because of suboptimal sequence features and low variability (>97% in HD). We suggest maximising patient coverage by selecting SNPs with high heterozygosity across populations, and preferentially targeting SNPs that lead to purine:purine mismatches in wild-type alleles to obtain potent allele-specific silencing. We therefore provide fundamental knowledge on strategies for optimising patient coverage of therapeutics for microsatellite expansion disorders by linking analysis of population genetic variation to the selection of molecular targets. PMID:25990798
Varela, Miguel A; Curtis, Helen J; Douglas, Andrew G L; Hammond, Suzan M; O'Loughlin, Aisling J; Sobrido, Maria J; Scholefield, Janine; Wood, Matthew J A
2016-02-01
Allele-specific gene therapy aims to silence expression of mutant alleles through targeting of disease-linked single-nucleotide polymorphisms (SNPs). However, SNP linkage to disease varies between populations, making such molecular therapies applicable only to a subset of patients. Moreover, not all SNPs have the molecular features necessary for potent gene silencing. Here we provide knowledge to allow the maximisation of patient coverage by building a comprehensive understanding of SNPs ranked according to their predicted suitability toward allele-specific silencing in 14 repeat expansion diseases: amyotrophic lateral sclerosis and frontotemporal dementia, dentatorubral-pallidoluysian atrophy, myotonic dystrophy 1, myotonic dystrophy 2, Huntington's disease and several spinocerebellar ataxias. Our systematic analysis of DNA sequence variation shows that most annotated SNPs are not suitable for potent allele-specific silencing across populations because of suboptimal sequence features and low variability (>97% in HD). We suggest maximising patient coverage by selecting SNPs with high heterozygosity across populations, and preferentially targeting SNPs that lead to purine:purine mismatches in wild-type alleles to obtain potent allele-specific silencing. We therefore provide fundamental knowledge on strategies for optimising patient coverage of therapeutics for microsatellite expansion disorders by linking analysis of population genetic variation to the selection of molecular targets.
Impact of organ shape variations on margin concepts for cervix cancer ART.
Seppenwoolde, Yvette; Stock, Markus; Buschmann, Martin; Georg, Dietmar; Bauer-Novotny, Kwei-Yuang; Pötter, Richard; Georg, Petra
2016-09-01
Target and organ movement motivate adaptive radiotherapy for cervix cancer patients. We investigated the dosimetric impact of margin concepts with different levels of complexity on both organ at risk (OAR) sparing and PTV coverage. Weekly CT and daily CBCT scans were delineated for 10 patients. The dosimetric impact of organ shape variations were evaluated for four (isotropic) margin concepts: two static PTVs (PTV 6mm and PTV 15mm ), a PTV based on ITV of the planning CT and CBCTs of the first treatment week (PTV ART ITV ) and an adaptive PTV based on a library approach (PTV ART Library ). Using static concepts, OAR doses increased with large margins, while smaller margins compromised target coverage. ART PTVs resulted in comparable target coverage and better sparing of bladder (V40Gy: 15% and 7% less), rectum (V40Gy: 18 and 6cc less) and bowel (V40Gy: 106 and 15cc less) compared to PTV 15mm . Target coverage evaluation showed that for elective fields a static 5mm margin sufficed. PTV ART Library achieved the best dosimetric results. However when weighing clinical benefit against workload, ITV margins based on repetitive movement evaluation during the first week also provide improvements over static margin concepts. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Acoustic window planning for ultrasound acquisition.
Göbl, Rüdiger; Virga, Salvatore; Rackerseder, Julia; Frisch, Benjamin; Navab, Nassir; Hennersperger, Christoph
2017-06-01
Autonomous robotic ultrasound has recently gained considerable interest, especially for collaborative applications. Existing methods for acquisition trajectory planning are solely based on geometrical considerations, such as the pose of the transducer with respect to the patient surface. This work aims at establishing acoustic window planning to enable autonomous ultrasound acquisitions of anatomies with restricted acoustic windows, such as the liver or the heart. We propose a fully automatic approach for the planning of acquisition trajectories, which only requires information about the target region as well as existing tomographic imaging data, such as X-ray computed tomography. The framework integrates both geometrical and physics-based constraints to estimate the best ultrasound acquisition trajectories with respect to the available acoustic windows. We evaluate the developed method using virtual planning scenarios based on real patient data as well as for real robotic ultrasound acquisitions on a tissue-mimicking phantom. The proposed method yields superior image quality in comparison with a naive planning approach, while maintaining the necessary coverage of the target. We demonstrate that by taking image formation properties into account acquisition planning methods can outperform naive plannings. Furthermore, we show the need for such planning techniques, since naive approaches are not sufficient as they do not take the expected image quality into account.
Massing, Louis Albert; Aboubakar, Soumah; Page, Anne-Laure; Cohuet, Sandra; Ngandwe, Adalbert; Mukomena Sompwe, Eric; Ramazani, Romain; Allheimen, Marcela; Levaillant, Philippe; Lechevalier, Pauline; Kashimi, Marie; de la Motte, Axelle; Calmejane, Arielle; Bouhenia, Malika; Dabire, Ernest; Bompangue, Didier; Kebela, Benoit; Porten, Klaudia
2018-01-01
Introduction Oral cholera vaccines are primarily recommended by the World Health Organization for cholera control in endemic countries. However, the number of cholera vaccines currently produced is very limited and examples of OCV use in endemic countries, and especially in urban settings, are scarce. A vaccination campaign was organized by Médecins Sans Frontières and the Ministry of Health in a highly endemic area in the Democratic Republic of Congo. This study aims to describe the vaccine coverage achieved with this highly targeted vaccination campaign and the acceptability among the vaccinated communities. Methods and findings We performed a cross-sectional survey using random spatial sampling. The study population included individuals one year old and above, eligible for vaccination, and residing in the areas targeted for vaccination in the city of Kalemie. Data sources were household interviews with verification by vaccination card. In total 2,488 people were included in the survey. Overall, 81.9% (95%CI: 77.9–85.3) of the target population received at least one dose of vaccine. The vaccine coverage with two doses was 67.2% (95%CI: 61.9–72.0) among the target population. The vaccine coverage was higher during the first round (74.0, 95%CI: 69.3–78.3) than during the second round of vaccination (69.1%, 95%CI: 63.9–74.0). Vaccination coverage was lower in male adults. The main reason for non-vaccination was to be absent during the campaign. No severe adverse events were notified during the interviews. Conclusions Cholera vaccination campaigns using highly targeted strategies are feasible in urban settings. High vaccination coverage can be obtained using door to door vaccination. However, alternative strategies should be considered to reach non-vaccinated populations like male adults and also in order to improve the efficiency of the interventions. PMID:29734337
DOE Office of Scientific and Technical Information (OSTI.GOV)
Warrell, G; Shvydka, D; Chen, C
Purpose: The superiority of a properly-administered combination of radiation therapy and hyperthermia over radiation alone in treatment of human cancers has been demonstrated in multiple studies examining radiobiology, local control, and survival. Unfortunately, hyperthermia is not yet a common modality in oncology practice, due in part to the technical difficulty of heating a deep-seated target volume to sufficient temperature. To address this problem, our group has invented a thermobrachytherapy (TB) seed based on a commonly-used low dose-rate permanent brachytherapy seed for implant in solid tumors. Instead of the tungsten radiographic marker of the standard seed, the TB seed contains onemore » of a self-regulating ferromagnetic alloy. Placement of a patient implanted with such seeds in an oscillating magnetic field generates heat via induction of eddy currents. We present the results of studies of the capability of clinically-realistic TB seed arrangements to adequately heat defined target volumes. Methods: Seed distributions for several past LDR prostate permanent implant brachytherapy patients were reproduced in the finite element analysis software package COMSOL Multiphysics 4.4, with the difference that TB seeds were modelled, rather than the radiation-only seeds actually used for their treatments. The implant geometries were mainly of the modified peripheral loading type; a range of prostatic volumes and blood perfusion rates likely to be seen in a clinical setting were examined. Results: According to the simulations, when distributed to optimize radiation dose, TB seeds also produce sufficient heat to provide thermal coverage of the target given proper selection of the magnetic field strength. However, the thermal distributions may be improved by additional use of hyperthermia-only seeds. Conclusion: A dual-modality seed intended as an alternative to and using the same implantation apparatus and technique as the standard LDR permanent implant seed has been successfully evaluated for its ability to provide sufficient hyperthermia in clinically-realistic implants. This work was partially supported by the National Institutes of Health (NIH) STTR Grant No. R41 CA153631-01A1.« less
A novel dose-based positioning method for CT image-guided proton therapy
Cheung, Joey P.; Park, Peter C.; Court, Laurence E.; Ronald Zhu, X.; Kudchadker, Rajat J.; Frank, Steven J.; Dong, Lei
2013-01-01
Purpose: Proton dose distributions can potentially be altered by anatomical changes in the beam path despite perfect target alignment using traditional image guidance methods. In this simulation study, the authors explored the use of dosimetric factors instead of only anatomy to set up patients for proton therapy using in-room volumetric computed tomographic (CT) images. Methods: To simulate patient anatomy in a free-breathing treatment condition, weekly time-averaged four-dimensional CT data near the end of treatment for 15 lung cancer patients were used in this study for a dose-based isocenter shift method to correct dosimetric deviations without replanning. The isocenter shift was obtained using the traditional anatomy-based image guidance method as the starting position. Subsequent isocenter shifts were established based on dosimetric criteria using a fast dose approximation method. For each isocenter shift, doses were calculated every 2 mm up to ±8 mm in each direction. The optimal dose alignment was obtained by imposing a target coverage constraint that at least 99% of the target would receive at least 95% of the prescribed dose and by minimizing the mean dose to the ipsilateral lung. Results: The authors found that 7 of 15 plans did not meet the target coverage constraint when using only the anatomy-based alignment. After the authors applied dose-based alignment, all met the target coverage constraint. For all but one case in which the target dose was met using both anatomy-based and dose-based alignment, the latter method was able to improve normal tissue sparing. Conclusions: The authors demonstrated that a dose-based adjustment to the isocenter can improve target coverage and/or reduce dose to nearby normal tissue. PMID:23635262
Restricted Field IMRT Dramatically Enhances IMRT Planning for Mesothelioma
DOE Office of Scientific and Technical Information (OSTI.GOV)
Allen, Aaron M.; Schofield, Deborah; Hacker, Fred
2007-12-01
Purpose: To improve the target coverage and normal tissue sparing of intensity-modulated radiotherapy (IMRT) for mesothelioma after extrapleural pneumonectomy. Methods and Materials: Thirteen plans from patients previously treated with IMRT for mesothelioma were replanned using a restricted field technique. This technique was novel in two ways. It limited the entrance beams to 200{sup o} around the target and three to four beams per case had their field apertures restricted down to the level of the heart or liver to further limit the contralateral lung dose. New constraints were added that included a mean lung dose of <9.5 Gy and volumemore » receiving {>=}5 Gy of <55%. Results: In all cases, the planning target volume coverage was excellent, with an average of 97% coverage of the planning target volume by the target dose. No change was seen in the target coverage with the new technique. The heart, kidneys, and esophagus were all kept under tolerance in all cases. The average mean lung dose, volume receiving {>=}20 Gy, and volume receiving {>=}5 Gy with the new technique was 6.6 Gy, 3.0%, and 50.8%, respectively, compared with 13.8 Gy, 15%, and 90% with the previous technique (p < 0.0001 for all three comparisons). The maximal value for any case in the cohort was 8.0 Gy, 7.3%, and 57.5% for the mean lung dose, volume receiving {>=}20 Gy, and volume receiving {>=}5 Gy, respectively. Conclusion: Restricted field IMRT provides an improved method to deliver IMRT to a complex target after extrapleural pneumonectomy. An upcoming Phase I trial will provide validation of these results.« less
Delaunay Triangulation as a New Coverage Measurement Method in Wireless Sensor Network
Chizari, Hassan; Hosseini, Majid; Poston, Timothy; Razak, Shukor Abd; Abdullah, Abdul Hanan
2011-01-01
Sensing and communication coverage are among the most important trade-offs in Wireless Sensor Network (WSN) design. A minimum bound of sensing coverage is vital in scheduling, target tracking and redeployment phases, as well as providing communication coverage. Some methods measure the coverage as a percentage value, but detailed information has been missing. Two scenarios with equal coverage percentage may not have the same Quality of Coverage (QoC). In this paper, we propose a new coverage measurement method using Delaunay Triangulation (DT). This can provide the value for all coverage measurement tools. Moreover, it categorizes sensors as ‘fat’, ‘healthy’ or ‘thin’ to show the dense, optimal and scattered areas. It can also yield the largest empty area of sensors in the field. Simulation results show that the proposed DT method can achieve accurate coverage information, and provides many tools to compare QoC between different scenarios. PMID:22163792
Multi-version software reliability through fault-avoidance and fault-tolerance
NASA Technical Reports Server (NTRS)
Vouk, Mladen A.; Mcallister, David F.
1989-01-01
A number of experimental and theoretical issues associated with the practical use of multi-version software to provide run-time tolerance to software faults were investigated. A specialized tool was developed and evaluated for measuring testing coverage for a variety of metrics. The tool was used to collect information on the relationships between software faults and coverage provided by the testing process as measured by different metrics (including data flow metrics). Considerable correlation was found between coverage provided by some higher metrics and the elimination of faults in the code. Back-to-back testing was continued as an efficient mechanism for removal of un-correlated faults, and common-cause faults of variable span. Software reliability estimation methods was also continued based on non-random sampling, and the relationship between software reliability and code coverage provided through testing. New fault tolerance models were formulated. Simulation studies of the Acceptance Voting and Multi-stage Voting algorithms were finished and it was found that these two schemes for software fault tolerance are superior in many respects to some commonly used schemes. Particularly encouraging are the safety properties of the Acceptance testing scheme.
Crowe, Scott B; Kairn, Tanya; Middlebrook, Nigel; Hill, Brendan; Christie, David R H; Knight, Richard T; Kenny, John; Langton, Christian M; Trapp, Jamie V
2013-01-01
Introduction This study examines and compares the dosimetric quality of radiotherapy treatment plans for prostate carcinoma across a cohort of 163 patients treated across five centres: 83 treated with three-dimensional conformal radiotherapy (3DCRT), 33 treated with intensity modulated radiotherapy (IMRT) and 47 treated with volumetric modulated arc therapy (VMAT). Methods Treatment plan quality was evaluated in terms of target dose homogeneity and organs at risk (OAR), through the use of a set of dose metrics. These included the mean, maximum and minimum doses; the homogeneity and conformity indices for the target volumes; and a selection of dose coverage values that were relevant to each OAR. Statistical significance was evaluated using two-tailed Welch's T-tests. The Monte Carlo DICOM ToolKit software was adapted to permit the evaluation of dose metrics from DICOM data exported from a commercial radiotherapy treatment planning system. Results The 3DCRT treatment plans offered greater planning target volume dose homogeneity than the other two treatment modalities. The IMRT and VMAT plans offered greater dose reduction in the OAR: with increased compliance with recommended OAR dose constraints, compared to conventional 3DCRT treatments. When compared to each other, IMRT and VMAT did not provide significantly different treatment plan quality for like-sized tumour volumes. Conclusions This study indicates that IMRT and VMAT have provided similar dosimetric quality, which is superior to the dosimetric quality achieved with 3DCRT. PMID:26229621
SU-E-J-221: A Novel Expansion Method for MRI Based Target Delineation in Prostate Radiotherapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ruiz, B; East Carolina University, Greenville, NC; Feng, Y
Purpose: To compare a novel bladder/rectum carveout expansion method on MRI delineated prostate to standard CT and expansion based methods for maintaining prostate coverage while providing superior bladder and rectal sparing. Methods: Ten prostate cases were planned to include four trials: MRI vs CT delineated prostate/proximal seminal vesicles, and each image modality compared to both standard expansions (8mm 3D expansion and 5mm posterior, i.e. ∼8mm) and carveout method expansions (5mm 3D expansion, 4mm posterior for GTV-CTV excluding expansion into bladder/rectum followed by additional 5mm 3D expansion to PTV, i.e. ∼1cm). All trials were planned to total dose 7920 cGy viamore » IMRT. Evaluation and comparison was made using the following criteria: QUANTEC constraints for bladder/rectum including analysis of low dose regions, changes in PTV volume, total control points, and maximum hot spot. Results: ∼8mm MRI expansion consistently produced the most optimal plan with lowest total control points and best bladder/rectum sparing. However, this scheme had the smallest prostate (average 22.9% reduction) and subsequent PTV volume, consistent with prior literature. ∼1cm MRI had an average PTV volume comparable to ∼8mm CT at 3.79% difference. Bladder QUANTEC constraints were on average less for the ∼1cm MRI as compared to the ∼8mm CT and observed as statistically significant with 2.64% reduction in V65. Rectal constraints appeared to follow the same trend. Case-by-case analysis showed variation in rectal V30 with MRI delineated prostate being most favorable regardless of expansion type. ∼1cm MRI and ∼8mm CT had comparable plan quality. Conclusion: MRI delineated prostate with standard expansions had the smallest PTV leading to margins that may be too tight. Bladder/rectum carveout expansion method on MRI delineated prostate was found to be superior to standard CT based methods in terms of bladder and rectal sparing while maintaining prostate coverage. Continued investigation is warranted for further validation.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fu, Yuchuan; Deng, Min; Zhou, Xiaojuan
To evaluate the lung sparing in intensity-modulated radiation therapy (IMRT) for patients with upper thoracic esophageal tumors extending inferiorly to the thorax by different beam arrangement. Overall, 15 patient cases with cancer of upper thoracic esophagus were selected for a retrospective treatment-planning study. Intensity-modulated radiation therapy plans using 4, 5, and 7 beams (4B, 5B, and 7B) were developed for each patient by direct machine parameter optimization (DMPO). All plans were evaluated with respect to dose volumes to irradiated targets and normal structures, with statistical comparisons made between 4B with 5B and 7B intensity-modulated radiation therapy plans. Differences among plansmore » were evaluated using a two-tailed Friedman test at a statistical significance of p < 0.05. The maximum dose, average dose, and the conformity index (CI) of planning target volume 1 (PTV1) were similar for 3 plans for each case. No significant difference of coverage for planning target volume 1 and maximum dose for spinal cords were observed among 3 plans in present study (p > 0.05). The average V{sub 5}, V{sub 13}, V{sub 20}, mean lung dose, and generalized equivalent uniform dose (gEUD) for the total lung were significantly lower in 4B-plans than those data in 5B-plans and 7B-plans (p < 0.01). Although the average V{sub 30} for the total lung were significantly higher in 4B-plans than those in 5B-plans and 7B-plans (p < 0.05). In addition, when comparing with the 4B-plans, the conformity/heterogeneity index of the 5B- and 7B-plans were significantly superior (p < 0.05). The 4B-intensity-modulated radiation therapy plan has advantage to address the specialized problem of lung sparing to low- and intermediate-dose exposure in the thorax when dealing with relative long tumors extended inferiorly to the thoracic esophagus for upper esophageal carcinoma with the cost for less conformity. Studies are needed to compare the superiority of volumetric modulated arc therapy with intensity-modulated radiation therapy technique.« less
Massat, Nathalie J; Douglas, Elaine; Waller, Jo; Wardle, Jane; Duffy, Stephen W
2015-07-24
Reducing cancer screening inequalities in England is a major focus of the 2011 Department of Health cancer outcome strategy. Screening coverage requires regular monitoring in order to implement targeted interventions where coverage is low. This study aimed to characterise districts with atypical coverage levels for cervical or breast screening. Observational study of district-level coverage in the English Cervical and Breast screening programmes in 2012. England, UK. All English women invited to participate in the cervical (age group 25-49 and 50-64) and breast (age group 50-64) screening programmes. Risk adjustment models for coverage were developed based on district-level characteristics. Funnel plots of adjusted coverage were constructed, and atypical districts examined by correlation analysis. Variability in coverage was primarily explained by population factors, whereas general practice characteristics had little independent effect. Deprivation and ethnicity other than white, Asian, black or mixed were independently associated with poorer coverage in both screening programmes, with ethnicity having the strongest effect; by comparison, the influence of Asian, black or mixed ethnic minority was limited. Deprivation, ethnicity and urbanisation largely accounted for the lower cervical screening coverage in London. However, for breast screening, being located in London remained a strong negative predictor. A subset of districts was identified as having atypical coverage across programmes. Correlates of deprivation in districts with relatively low adjusted coverage were substantially different from overall correlates of deprivation. These results inform the continuing drive to reduce avoidable cancer deaths in England, and encourage implementation of targeted interventions in communities residing in districts identified as having atypically low coverage. Sequential implementation to monitor the impact of local interventions would help accrue evidence on 'what works'. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Comparing Type of Health Insurance Among Low-Income Children: A Mixed-Methods Study from Oregon
Wallace, Lorraine; Selph, Shelley; Westfall, Nicholas; Crocker, Stephanie
2016-01-01
We employed a mixed-methods study of primary data from a statewide household survey and in-person interviews with parents to examine—quantitatively and qualitatively—whether low-income children experienced differences between public and private insurance coverage types. We carried out 24 in-depth interviews with a sub-sample of respondents to Oregon’s 2005 Children’s Access to Healthcare Study (CAHS), analyzed using a standard iterative process and immersion/crystallization cycles. Qualitative findings guided quantitative analyses of CAHS data that assessed associations between insurance type and parental-reported unmet children’s health care needs. Interviewees uniformly reported that stable health insurance was important, but there was no consensus regarding which type was superior. Quantitatively, there were only a few significant differences. Cross-sectionally, compared with private coverage, public coverage was associated with higher odds of unmet specialty care needs (odds ratio [OR] 3.54; 95% confidence interval [CI] 1.52–8.24). Comparing full-year coverage patterns, those with public coverage had lower odds of unmet prescription needs (OR 0.60, 95% CI 0.36–0.99) and unmet mental health counseling needs (OR 0.24, 95% CI 0.10–0.63), compared with privately covered children. Low-income Oregon parents reported few differences in their child’s experience with private versus public coverage. PMID:21052802
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ahmad, I; Quinn, K; Seebach, A
2015-06-15
Purpose: This study evaluates the dosimetric differences using volumetric modulated arc therapy (VMAT) in patients previously treated with intensity modulated radiation therapy IMRT for stereotactic body radiotherapy (SBRT) in early stage lung cancer. Methods: We evaluated 9 consecutive medically inoperable lung cancer patients at the start of the SBRT program who were treated with IMRT from November 2010 to October 2011. These patients were treated using 6 MV energy. The 9 cases were then re-planned with VMAT performed with arc therapy using 6 MV flattening filter free (FFF) energy with the same organs at risk (OARS) constraints. Data collected formore » the treatment plans included target coverage, beam on time, dose to OARS and gamma pass rate. Results: Five patients were T1N0 and four patients were T2N0 with all tumors less than 5 cm. The average GTV was 13.02 cm3 (0.83–40.87) and average PTV was 44.65 cm3 (14.06–118.08). The IMRT plans had a mean of 7.2 angles (6–9) and 5.4 minutes (3.6–11.1) per plan. The VMAT plans had a mean of 2.8 arcs (2–3) and 4.0 minutes (2.2–6.0) per plan. VMAT had slightly more target coverage than IMRT with average increase in D95 of 2.68% (1.24–5.73) and D99 of 3.65% (0.88–8.77). VMAT produced lower doses to all OARs. The largest reductions were in maximum doses to the spinal cord with an average reduction of 24.1%, esophagus with an average reduction of 22.1%, and lung with an average reduction in the V20 of 16.3% The mean gamma pass rate was 99.8% (99.2–100) at 3 mm and 3% for VMAT with comparable values for IMRT. Conclusion: These findings suggest that using VMAT for SBRT in early stage lung cancer is superior to IMRT in terms of dose coverage, OAR dose and a lower treatment delivery time with a similar gamma pass rate.« less
TU-AB-BRB-01: Coverage Evaluation and Probabilistic Treatment Planning as a Margin Alternative
DOE Office of Scientific and Technical Information (OSTI.GOV)
Siebers, J.
The accepted clinical method to accommodate targeting uncertainties inherent in fractionated external beam radiation therapy is to utilize GTV-to-CTV and CTV-to-PTV margins during the planning process to design a PTV-conformal static dose distribution on the planning image set. Ideally, margins are selected to ensure a high (e.g. >95%) target coverage probability (CP) in spite of inherent inter- and intra-fractional positional variations, tissue motions, and initial contouring uncertainties. Robust optimization techniques, also known as probabilistic treatment planning techniques, explicitly incorporate the dosimetric consequences of targeting uncertainties by including CP evaluation into the planning optimization process along with coverage-based planning objectives. Themore » treatment planner no longer needs to use PTV and/or PRV margins; instead robust optimization utilizes probability distributions of the underlying uncertainties in conjunction with CP-evaluation for the underlying CTVs and OARs to design an optimal treated volume. This symposium will describe CP-evaluation methods as well as various robust planning techniques including use of probability-weighted dose distributions, probability-weighted objective functions, and coverage optimized planning. Methods to compute and display the effect of uncertainties on dose distributions will be presented. The use of robust planning to accommodate inter-fractional setup uncertainties, organ deformation, and contouring uncertainties will be examined as will its use to accommodate intra-fractional organ motion. Clinical examples will be used to inter-compare robust and margin-based planning, highlighting advantages of robust-plans in terms of target and normal tissue coverage. Robust-planning limitations as uncertainties approach zero and as the number of treatment fractions becomes small will be presented, as well as the factors limiting clinical implementation of robust planning. Learning Objectives: To understand robust-planning as a clinical alternative to using margin-based planning. To understand conceptual differences between uncertainty and predictable motion. To understand fundamental limitations of the PTV concept that probabilistic planning can overcome. To understand the major contributing factors to target and normal tissue coverage probability. To understand the similarities and differences of various robust planning techniques To understand the benefits and limitations of robust planning techniques.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xu, H.
The accepted clinical method to accommodate targeting uncertainties inherent in fractionated external beam radiation therapy is to utilize GTV-to-CTV and CTV-to-PTV margins during the planning process to design a PTV-conformal static dose distribution on the planning image set. Ideally, margins are selected to ensure a high (e.g. >95%) target coverage probability (CP) in spite of inherent inter- and intra-fractional positional variations, tissue motions, and initial contouring uncertainties. Robust optimization techniques, also known as probabilistic treatment planning techniques, explicitly incorporate the dosimetric consequences of targeting uncertainties by including CP evaluation into the planning optimization process along with coverage-based planning objectives. Themore » treatment planner no longer needs to use PTV and/or PRV margins; instead robust optimization utilizes probability distributions of the underlying uncertainties in conjunction with CP-evaluation for the underlying CTVs and OARs to design an optimal treated volume. This symposium will describe CP-evaluation methods as well as various robust planning techniques including use of probability-weighted dose distributions, probability-weighted objective functions, and coverage optimized planning. Methods to compute and display the effect of uncertainties on dose distributions will be presented. The use of robust planning to accommodate inter-fractional setup uncertainties, organ deformation, and contouring uncertainties will be examined as will its use to accommodate intra-fractional organ motion. Clinical examples will be used to inter-compare robust and margin-based planning, highlighting advantages of robust-plans in terms of target and normal tissue coverage. Robust-planning limitations as uncertainties approach zero and as the number of treatment fractions becomes small will be presented, as well as the factors limiting clinical implementation of robust planning. Learning Objectives: To understand robust-planning as a clinical alternative to using margin-based planning. To understand conceptual differences between uncertainty and predictable motion. To understand fundamental limitations of the PTV concept that probabilistic planning can overcome. To understand the major contributing factors to target and normal tissue coverage probability. To understand the similarities and differences of various robust planning techniques To understand the benefits and limitations of robust planning techniques.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, J; Yang, Z; Hu, W
2015-06-15
Purpose: This study was to investigate the dosimetric benefit of a novel intensity modulated radiation therapy (IMRT) technique for irradiating the left breast and regional lymph node (RLN). Methods: The breast and RLN (internal mammary node and periclavicular node) and normal tissue were contoured for 16 consecutive left-sided breast cancer patients previously treated with RT after lumpectomy. Nine equi-spaced fields IMRT (9 -field IMRT), tangential multi-beam IMRT (tangential-IMRT) and IMRT with fixed-jaw technique (FJT-IMRT) were developed and compared with three-dimensional conformal RT (3DCRT). Prescribed dose was 50 Gy in 25 fractions. Dose distributions and dose volume histograms were used tomore » evaluate plans. Results: All IMRTs achieved similar target coverage and substantially reduced heart V30 and V20 compared to the 3DCRT. The average heart mean dose had different changes, which were 9.0Gy for 9-field IMRT, 5.7Gy for tangential-IMRT and 4.2Gy for FJT-IMRT. For the contralateral lung and breast, the 9-field IMRT has the highest mean dose; and the FJT-IMRT and tangential-IMRT had similar lower value. For the thyroid, both 9-field IMRT and FJT-IMRT had similar V30 (20% and 22%) and were significantly lower than that of 3DCRT (34%) and tangential-IMRT (46%). Moreover, the thyroid mean dose of FJT-IMRT is the lowest. For cervical esophagus and humeral head, the FJT-IMRT also had the best sparing. Conclusion: All 9-field IMRT, tangential-IMRT and FJT-IMRT had superiority for targets coverage and substantially reduced the heart volume of high dose irradiation. The FJT-IMRT showed advantages of avoiding the contralateral breast and lung irradiation and decreasing the thyroid, humeral head and cervical esophagus radiation dose at the expense of a slight monitor units (MUs) increasing.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Moteabbed, M; Depauw, N; Kooy, H
Purpose: To investigate the dosimetric benefits of pencil beam scanning (PBS) compared with passive scattered (PS) proton therapy for treatment of pediatric head&neck patients as a function of the PBS spot size and explore the advantages of using apertures in PBS. Methods: Ten pediatric patients with head&neck cancers treated by PS proton therapy at our institution were retrospectively selected. The histologies included rhabdomyosarcoma, ependymoma, astrocytoma, craniopharyngioma and germinoma. The prescribed dose ranged from 36 to 54 Gy(RBE). Five PBS plans were created for each patient using variable spot size (average sigma at isocenter) and choice of beam specific apertures: (1)more » 10mm spots, (2) 10mm spots with apertures, (3) 6mm spots, (4) 6mm spots with apertures, and (5) 3mm spots. The plans were optimized for intensity modulated proton therapy (IMPT) with no single beam uniformity constraints. Dose volume indices as well as equivalent uniform dose (EUD) were compared between PS and PBS plans. Results: Although target coverage was clinically adequate for all cases, the plans with largest (10mm) spots provide inferior quality compared with PS in terms of dose to organs-at-risk (OAR). However, adding apertures to these plans ensured lower OAR dose than PS. The average EUD difference between PBS and PS plans over all patients and organs at risk were (1) 2.5%, (2) −5.1%, (3) -5%, (4) −7.8%, and (5) −9.5%. As the spot size decreased, more conformal plans were achieved that offered similar target coverage but lower dose to the neighboring healthy organs, while alleviating the need for using apertures. Conclusion: The application of PBS does not always translate to better plan qualities compared to PS depending on the available beam spot size. We recommend that institutions with spot size larger than ∼6mm at isocenter consider using apertures to guarantee clinically comparable or superior dosimetric efficacy to PS treatments.« less
Shuaibu, Faisal M; Birukila, Gerida; Usman, Samuel; Mohammed, Ado; Galway, Michael; Corkum, Melissa; Damisa, Eunice; Mkanda, Pascal; Mahoney, Frank; Wa Nganda, Gatei; Vertefeuille, John; Chavez, Anna; Meleh, Sule; Banda, Richard; Some, Almai; Mshelia, Hyelni; Umar, Al-Umra; Enemaku, Ogu; Etsano, Andrew
2016-02-01
The use of Inactivated Polio Vaccine (IPV) in routine immunization to replace Oral Polio Vaccine (OPV) is crucial in eradicating polio. In June 2014, Nigeria launched an IPV campaign in the conflict-affected states of Borno and Yobe, the largest ever implemented in Africa. We present the initiatives and lessons learned. The 8-day event involved two parallel campaigns. OPV target age was 0-59 months, while IPV targeted all children aged 14 weeks to 59 months. The Borno state primary health care agency set up temporary health camps for the exercise and treated minor ailments for all. The target population for the OPV campaign was 685,674 children in Borno and 113,774 in Yobe. The IPV target population for Borno was 608,964 and for Yobe 111,570. OPV coverage was 105.1 per cent for Borno and 103.3 per cent for Yobe. IPV coverage was 102.9 per cent for Borno and 99.1 per cent for Yobe. (Where we describe coverage as greater than 100 per cent, this reflects original underestimates of the target populations.) A successful campaign and IPV immunization is viable in conflict areas.
ERIC Educational Resources Information Center
Gems, Gerald R.
1998-01-01
Traces and compares the histories of Black and American-Indian participation in collegiate and professional football. Discusses athletic participation by minority groups as a challenge to segregation and notions of White superiority; as a challenge to the persistence of racist stereotypes in media coverage; and as a foundation for the…
Infrared-enhanced TV for fire detection
NASA Technical Reports Server (NTRS)
Hall, J. R.
1978-01-01
Closed-circuit television is superior to conventional smoke or heat sensors for detecting fires in large open spaces. Single TV camera scans entire area, whereas many conventional sensors and maze of interconnecting wiring might be required to get same coverage. Camera is monitored by person who would trip alarm if fire were detected, or electronic circuitry could process camera signal for fully-automatic alarm system.
Zöllner, Caroline; De Allegri, Manuela; Louis, Valérie R; Yé, Maurice; Sié, Ali; Tiendrebéogo, Justin; Jahn, Albrecht; Müller, Olaf
2015-03-01
Insecticide-treated mosquito nets (ITNs) are an essential tool of the Roll Back Malaria strategy. An increasing number of African countries have embarked on mass distribution campaigns of long-lasting insecticide-treated nets (LLINs) with the ultimate goal of universal coverage. Such a national campaign with the goal of one ITN for every two people has been conducted in Burkina Faso in 2010. Our aim was to assess the coverage and equity effect of the universal distribution campaign of LLINs in Burkina Faso and to identify determinants of ITN ownership across households after the campaign. We evaluated its effects through comparison of data from two household surveys conducted in early 2010 (before the campaign) and early 2011 (after the campaign) on a representative rural district in north-western Burkina Faso. Data were collected on household characteristics (including socio-economic status) and ITN ownership. We used concentration curves and indices to compare ITN coverage indicators before and after the campaign and multilevel multivariate logistic regression to estimate factors associated with achievement of the universal coverage target in 2011. The survey included 1106 households in 2010 and 1094 in 2011. We found that the proportion of households with at least one ITN increased from 59% before the campaign to 99% afterwards, whereas the concentration index dropped from 0.087 (standard error (SE): 0.014) to 0.002 (SE: 0.002). Fifty-two per cent of households reached the target of one ITN for every two people per household, with the relevant concentration index at -0.031 (SE: 0.016). Eighty-six per cent of households owned at least one ITN for every three people. The main characteristics significantly associated with the targeted intra-household coverage were family size and distance to the health centre but not socio-economic status. In conclusion, despite not having fully met its target, the national LLIN campaign achieved a high level of coverage and fostered equity. Published by Oxford University Press in association with The London School of Hygiene and Tropical Medicine © The Author 2014; all rights reserved.
Mereckiene, J; Cotter, S; Nicoll, A; Lopalco, P; Noori, T; Weber, Jt; D'Ancona, F; Levy-Bruhl, D; Dematte, L; Giambi, C; Valentiner-Branth, P; Stankiewicz, I; Appelgren, E; O Flanagan, D
2014-04-24
Since 2008, annual surveys of influenza vaccination policies, practices and coverage have been undertaken in 29 European Union (EU)/ European Economic Area (EEA) countries. After 2009, this monitored the impact of European Council recommendation to increase vaccination coverage to 75% among risk groups. This paper summarises the results of three seasonal influenza seasons: 2008/09, 2009/10 and 2010/11. In 2008/09, 27/29 countries completed the survey; in 2009/10 and 2010/11, 28/29 completed it. All or almost all countries recommended vaccination of older people (defined as those aged ≥50, ≥55, ≥59, ≥60 or ≥65 years), and people aged ≥6 months with clinical risk and healthcare workers. A total of 23 countries provided vaccination coverage data for older people, but only 7 and 10 had data for the clinical risk groups and healthcare workers, respectively. The number of countries recommending vaccination for some or all pregnant women increased from 10 in 2008/09 to 22 in 2010/11. Only three countries could report coverage among pregnant women. Seasonal influenza vaccination coverage during and after the pandemic season in older people and clinical groups remained unchanged in countries with higher coverage. However, small decreases were seen in most countries during this period. The results of the surveys indicate that most EU/EEA countries recommend influenza vaccination for the main target groups; however, only a few countries have achieved the target of 75% coverage among risk groups. Coverage among healthcare workers remained low.
Varan, Aiden K; Rodriguez-Lainz, Alfonso; Hill, Holly A; Elam-Evans, Laurie D; Yankey, David; Li, Qian
2017-08-01
Healthy People 2020 targets high vaccination coverage among children. Although reductions in coverage disparities by race/ethnicity have been described, data by nativity are limited. The National Immunization Survey is a random-digit-dialed telephone survey that estimates vaccination coverage among U.S. children aged 19-35 months. We assessed coverage among 52,441 children from pooled 2010-2012 data for individual vaccines and the combined 4:3:1:3*:3:1:4 series (which includes ≥4 doses of diphtheria, tetanus, and acellular pertussis vaccine/diphtheria and tetanus toxoids vaccine/diphtheria, tetanus toxoids, and pertussis vaccine, ≥3 doses of poliovirus vaccine, ≥1 dose of measles-containing vaccine, ≥3 or ≥4 doses of Haemophilus influenzae type b vaccine (depending on product type of vaccine; denoted as 3* in the series name), ≥3 doses of hepatitis B vaccine, ≥1 dose of varicella vaccine, and ≥4 doses of pneumococcal conjugate vaccine). Coverage estimates controlling for sociodemographic factors and multivariable logistic regression modeling for 4:3:1:3*:3:1:4 series completion are presented. Significantly lower coverage among foreign-born children was detected for DTaP, hepatitis A, hepatitis B, Hib, pneumococcal conjugate, and rotavirus vaccines, and for the combined series. Series completion disparities persisted after control for demographic, access-to-care, poverty, and language effects. Substantial and potentially widening disparities in vaccination coverage exist among foreign-born children. Improved immunization strategies targeting this population and continued vaccination coverage monitoring by nativity are needed.
Sources and Coverage of Medical News on Front Pages of US Newspapers
Lai, William Y. Y.; Lane, Trevor; Jones, Alison
2009-01-01
Background Medical news that appears on newspaper front pages is intended to reach a wide audience, but how this type of medical news is prepared and distributed has not been systematically researched. We thus quantified the level of visibility achieved by front-page medical stories in the United States and analyzed their news sources. Methodology Using the online resource Newseum, we investigated front-page newspaper coverage of four prominent medical stories, and a high-profile non-medical news story as a control, reported in the US in 2007. Two characteristics were quantified by two raters: which newspaper titles carried each target front-page story (interrater agreement, >96%; kappa, >0.92) and the news sources of each target story (interrater agreement, >94%; kappa, >0.91). National rankings of the top 200 US newspapers by audited circulation were used to quantify the extent of coverage as the proportion of the total circulation of ranked newspapers in Newseum. Findings In total, 1630 front pages were searched. Each medical story appeared on the front pages of 85 to 117 (67.5%–78.7%) ranked newspaper titles that had a cumulative daily circulation of 23.1 to 33.4 million, or 61.8% to 88.4% of all newspapers. In contrast, the non-medical story achieved front-page coverage in 152 (99.3%) newspaper titles with a total circulation of 41.0 million, or 99.8% of all newspapers. Front-page medical stories varied in their sources, but the Washington Post, Los Angeles Times, New York Times and the Associated Press together supplied 61.7% of the total coverage of target front-page medical stories. Conclusion Front-page coverage of medical news from different sources is more accurately revealed by analysis of circulation counts rather than of newspaper titles. Journals wishing to widen knowledge of research news and organizations with important health announcements should target at least the four dominant media organizations identified in this study. PMID:19724643
Vugmeyster, Yulia; Rohde, Cynthia; Perreault, Mylene; Gimeno, Ruth E; Singh, Pratap
2013-01-01
TAM-163, an agonist monoclonal antibody targeting tyrosine receptor kinase-B (TrkB), is currently being investigated as a potential body weight modulatory agent in humans. To support the selection of the dose range for the first-in-human (FIH) trial of TAM-163, we conducted a mechanistic analysis of the pharmacokinetic (PK) and pharmacodynamic (PD) data (e.g., body weight gain) obtained in lean cynomolgus and obese rhesus monkeys following single doses ranging from 0.3 to 60 mg/kg. A target-mediated drug disposition (TMDD) model was used to describe the observed nonlinear PK and Emax approach was used to describe the observed dose-dependent PD effect. The TMDD model development was supported by the experimental determination of the binding affinity constant (9.4 nM) and internalization rate of the drug-target complex (2.08 h(-1)). These mechanistic analyses enabled linking of exposure, target (TrkB) coverage, and pharmacological activity (e.g., PD) in monkeys, and indicated that ≥ 38% target coverage (time-average) was required to achieve significant body weight gain in monkeys. Based on the scaling of the TMDD model from monkeys to humans and assuming similar relationship between the target coverage and pharmacological activity between monkey and humans, subcutaneous (SC) doses of 1 and 15 mg/kg in humans were projected to be the minimally and the fully pharmacologically active doses, respectively. Based on the minimal anticipated biological effect level (MABEL) approach for starting dose selection, the dose of 0.05 mg/kg (3 mg for a 60 kg human) SC was recommended as the starting dose for FIH trials, because at this dose level<10% target coverage was projected at Cmax (and all other time points). This study illustrates a rational mechanistic approach for the selection of FIH dose range for a therapeutic protein with a complex model of action.
Metcalf, C J E; Tatem, A; Bjornstad, O N; Lessler, J; O'Reilly, K; Takahashi, S; Cutts, F; Grenfell, B T
2015-05-01
Measles vaccination is estimated to have averted 13·8 million deaths between 2000 and 2012. Persisting heterogeneity in coverage is a major contributor to continued measles mortality, and a barrier to measles elimination and introduction of rubella-containing vaccine. Our objective is to identify determinants of inequities in coverage, and how vaccine delivery must change to achieve elimination goals, which is a focus of the WHO Decade of Vaccines. We combined estimates of travel time to the nearest urban centre (⩾50 000 people) with vaccination data from Demographic Health Surveys to assess how remoteness affects coverage in 26 African countries. Building on a statistical mapping of coverage against age and geographical isolation, we quantified how modifying the rate and age range of vaccine delivery affects national coverage. Our scenario analysis considers increasing the rate of delivery of routine vaccination, increasing the target age range of routine vaccination, and enhanced delivery to remote areas. Geographical isolation plays a key role in defining vaccine inequity, with greater inequity in countries with lower measles vaccine coverage. Eliminating geographical inequities alone will not achieve thresholds for herd immunity, indicating that changes in delivery rate or age range of routine vaccination will be required. Measles vaccine coverage remains far below targets for herd immunity in many countries on the African continent and is likely to be inadequate for achieving rubella elimination. The impact of strategies such as increasing the upper age range eligible for routine vaccination should be considered.
Is universal health coverage the practical expression of the right to health care?
Ooms, Gorik; Latif, Laila A; Waris, Attiya; Brolan, Claire E; Hammonds, Rachel; Friedman, Eric A; Mulumba, Moses; Forman, Lisa
2014-02-24
The present Millennium Development Goals are set to expire in 2015 and their next iteration is now being discussed within the international community. With regards to health, the World Health Organization proposes universal health coverage as a 'single overarching health goal' for the next iteration of the Millennium Development Goals.The present Millennium Development Goals have been criticised for being 'duplicative' or even 'competing alternatives' to international human rights law. The question then arises, if universal health coverage would indeed become the single overarching health goal, replacing the present health-related Millennium Development Goals, would that be more consistent with the right to health? The World Health Organization seems to have anticipated the question, as it labels universal health coverage as "by definition, a practical expression of the concern for health equity and the right to health".Rather than waiting for the negotiations to unfold, we thought it would be useful to verify this contention, using a comparative normative analysis. We found that--to be a practical expression of the right to health--at least one element is missing in present authoritative definitions of universal health coverage: a straightforward confirmation that international assistance is essential, not optional.But universal health coverage is a 'work in progress'. A recent proposal by the United Nations Sustainable Development Solutions Network proposed universal health coverage with a set of targets, including a target for international assistance, which would turn universal health coverage into a practical expression of the right to health care.
Seo, Jeongmin; Lim, Juwon
2018-05-05
Influenza is a major cause of morbidity and mortality worldwide. Annual vaccination is effective in its prevention and is recommended especially in susceptible populations such as the elderly over 65 years, children younger than 5, pregnant women, and people with chronic diseases. Overall, South Korea has a high vaccination rate owing to its National Immunization Program, although the method and extent of its coverage varies among the target subgroups. The aim of this study is to assess the trend of influenza vaccination coverage between 2005 and 2014 in South Korea to address the influence of sociodemographic and disease factors on vaccination behavior. Also, we aim to compare the vaccination coverage of target subgroups and evaluate the effect of relevant policies to provide suggestions for their improvement. A total of 61,036 respondents from the Korea National Health and Nutrition Examination Surveys III to VI were included. The total influenza vaccination coverage increased from 38.0% in 2005 to 44.1% in 2014. Vaccination coverage was higher among the elderly aged ≥65 years (range, 70.0-79.8%; p-for-trend <0.001) and children under 5 (range, 64.6-78.9%; p-for-trend < 0.001) than among pregnant women (range, 9.4-37.8%; p-for-trend = 0.122) and people with chronic diseases (range, 29.6-42.6%; p-for-trend = 0.068) from 2005 to 2014. High vaccination coverage was associated with female gender, rural residence, low education level, high income, and increasing number of chronic diseases. But the effect of high income on high vaccination coverage was absent in the elderly aged ≥65 years and children under 5. Influenza vaccination rates have steadily increased from 2005 to 2014 in South Korea. Disparities between target groups correspond to their financial coverage under the National Immunization Program, and financial aids remove the influence of high income on higher vaccination rates. Future vaccination policies should focus on pregnant women and people with chronic diseases. Copyright © 2018 Elsevier Ltd. All rights reserved.
Shi, Binbin; Wei, Wei; Wang, Yihuai; Shu, Wanneng
2016-01-01
In high-density sensor networks, scheduling some sensor nodes to be in the sleep mode while other sensor nodes remain active for monitoring or forwarding packets is an effective control scheme to conserve energy. In this paper, a Coverage-Preserving Control Scheduling Scheme (CPCSS) based on a cloud model and redundancy degree in sensor networks is proposed. Firstly, the normal cloud model is adopted for calculating the similarity degree between the sensor nodes in terms of their historical data, and then all nodes in each grid of the target area can be classified into several categories. Secondly, the redundancy degree of a node is calculated according to its sensing area being covered by the neighboring sensors. Finally, a centralized approximation algorithm based on the partition of the target area is designed to obtain the approximate minimum set of nodes, which can retain the sufficient coverage of the target region and ensure the connectivity of the network at the same time. The simulation results show that the proposed CPCSS can balance the energy consumption and optimize the coverage performance of the sensor network. PMID:27754405
Shi, Binbin; Wei, Wei; Wang, Yihuai; Shu, Wanneng
2016-10-14
In high-density sensor networks, scheduling some sensor nodes to be in the sleep mode while other sensor nodes remain active for monitoring or forwarding packets is an effective control scheme to conserve energy. In this paper, a Coverage-Preserving Control Scheduling Scheme (CPCSS) based on a cloud model and redundancy degree in sensor networks is proposed. Firstly, the normal cloud model is adopted for calculating the similarity degree between the sensor nodes in terms of their historical data, and then all nodes in each grid of the target area can be classified into several categories. Secondly, the redundancy degree of a node is calculated according to its sensing area being covered by the neighboring sensors. Finally, a centralized approximation algorithm based on the partition of the target area is designed to obtain the approximate minimum set of nodes, which can retain the sufficient coverage of the target region and ensure the connectivity of the network at the same time. The simulation results show that the proposed CPCSS can balance the energy consumption and optimize the coverage performance of the sensor network.
Exploring What’s Missing: What Do Target Absent Trials Reveal About Autism Search Superiority?
Keehn, Brandon; Joseph, Robert M.
2016-01-01
We used eye-tracking to investigate the roles of enhanced discrimination and peripheral selection in superior visual search in autism spectrum disorder (ASD). Children with ASD were faster at visual search than their typically developing peers. However, group differences in performance and eye-movements did not vary with the level of difficulty of discrimination or selection. Rather, consistent with prior ASD research, group differences were mainly the effect of faster performance on target-absent trials. Eye-tracking revealed a lack of left-visual-field search asymmetry in ASD, which may confer an additional advantage when the target is absent. Lastly, ASD symptomatology was positively associated with search superiority, the mechanisms of which may shed light on the atypical brain organization that underlies social-communicative impairment in ASD. PMID:26762114
Murthy, Kk; Shukeili, Ka; Kumar, Ss; Davis, Ca; Chandran, Rr; Namrata, S
2010-01-01
To assess the potential advantage of intensity-modulated radiotherapy (IMRT) over 3D-conformal radiotherapy (3D-CRT) planning in postoperative adjuvant radiotherapy for patients with gastric carcinoma. In a retrospective study, for plan comparison, dose distribution was recalculated in 15 patients treated with 3D-CRT on the contoured structures of same CT images using an IMRT technique. 3D-conformal plans with three fields and four-fields were compared with seven-field dynamic IMRT plans. The different plans were compared by analyzing the dose coverage of planning target volume using TV(95), D(mean), uniformity index, conformity index and homogeneity index parameters. To assess critical organ sparing, D(mean), D(max), dose to one-third and two-third volumes of the OARs and percentage of volumes receiving more than their tolerance doses were compared. The average dose coverage values of PTV with 3F-CRT and 4F-CRT plans were comparable, where as IMRT plans achieved better target coverage(p<0.001) with higher conformity index value of 0.81±0.07 compared to both the 3D-CRT plans. The doses to the liver and bowel reduced significantly (p<0.001) with IMRT plans compared to other 3D-CRT plans. For all OARs the percentage of volumes receiving more than their tolerance doses were reduced with the IMRT plans. This study showed that a better target coverage and significant dose reduction to OARs could be achieved with the IMRT plans. The IMRT can be preferred with caution for organ motion. The authors are currently studying organ motion in the upper abdomen to use IMRT for patient treatment.
Liu, Zhong; Gao, Xiaoguang; Fu, Xiaowei
2018-05-08
In this paper, we mainly study a cooperative search and coverage algorithm for a given bounded rectangle region, which contains several unknown stationary targets, by a team of unmanned aerial vehicles (UAVs) with non-ideal sensors and limited communication ranges. Our goal is to minimize the search time, while gathering more information about the environment and finding more targets. For this purpose, a novel cooperative search and coverage algorithm with controllable revisit mechanism is presented. Firstly, as the representation of the environment, the cognitive maps that included the target probability map (TPM), the uncertain map (UM), and the digital pheromone map (DPM) are constituted. We also design a distributed update and fusion scheme for the cognitive map. This update and fusion scheme can guarantee that each one of the cognitive maps converges to the same one, which reflects the targets’ true existence or absence in each cell of the search region. Secondly, we develop a controllable revisit mechanism based on the DPM. This mechanism can concentrate the UAVs to revisit sub-areas that have a large target probability or high uncertainty. Thirdly, in the frame of distributed receding horizon optimizing, a path planning algorithm for the multi-UAVs cooperative search and coverage is designed. In the path planning algorithm, the movement of the UAVs is restricted by the potential fields to meet the requirements of avoiding collision and maintaining connectivity constraints. Moreover, using the minimum spanning tree (MST) topology optimization strategy, we can obtain a tradeoff between the search coverage enhancement and the connectivity maintenance. The feasibility of the proposed algorithm is demonstrated by comparison simulations by way of analyzing the effects of the controllable revisit mechanism and the connectivity maintenance scheme. The Monte Carlo method is employed to validate the influence of the number of UAVs, the sensing radius, the detection and false alarm probabilities, and the communication range on the proposed algorithm.
Increasing influenza vaccination coverage in recommended population groups in Europe.
Blank, Patricia R; Szucs, Thomas D
2009-04-01
The clinical and economic burden of seasonal influenza is frequently underestimated. The cornerstone of controlling and preventing influenza is vaccination. National and international guidelines aim to implement immunization programs and targeted vaccination-coverage rates, which should help to enhance the vaccine uptake, especially in the at-risk population. This review purposes to highlight the vaccination guidelines and the actual vaccination situation in four target groups (the elderly, people with underlying chronic conditions, healthcare workers and children) from a European point of view.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yan, S; Depauw, N; Flanz, J
2016-06-15
Purpose: Gantry-less proton treatment facility could lower the capital cost of proton therapy. This study investigates the dosimetric feasibility of using only coplanar pencil beam scanning (PBS) beams for those patients who had beam angles that would not have been deliverable without the gantry. Those coplanar beams are implemented on gantry-less horizontal beam-line with patients in sitting or standing positions. Methods: We have selected ten patients (seven head-and-neck, one thoracic, one abdominal and one pelvic case) with clinically delivered double scattering (DS) or PBS treatment plans with beam angles that were challenging to achieve without a gantry. After removing thesemore » beams angles, PBS plans were optimized for gantry-less intensity modulated proton therapy (IMPT) or single field optimization (SFO) with multi-criteria optimization (MCO). For head-and-neck patients who were treated by DS, we generated PBS plans with non-coplanar beams for comparison. Dose-volume-histograms (DVHs), target homogeneity index (HI), mean dose, D-2 and D-98 were reported. Robustness analysis was performed with ±2.5 mm setup errors and ±3.5% range uncertainties for three head-and-neck patients. Results: PBS-gantry-less plans provided more homogenous target coverage and significant improvements on organs-at-risk (OARs) sparing, compared to passive scattering treatments with a gantry. The PBS gantry-less treatments reduced the HI for target coverage by 1.3% to 47.2%, except for a suprasellar patient and a liver patient. The PBS-gantry-less plans reduced the D-mean of OARs by 3.6% to 67.4%. The PBS-gantry plans had similar target coverage and only marginal improvements on OAR sparing as compared to the PBS-gantry-less plans. These two PBS plans also had similar robustness relative to range uncertainties and setup errors. Conclusion: The gantry-less plans have with less mean dose to OARs and more homogeneous target coverage. Although the PBS-gantry plans have slightly improved target coverage and OARs sparing, the overall benefit of having a gantry to provide non-coplanar beams is debatable.« less
Contrapower Harassment in the Sport Management Classroom
ERIC Educational Resources Information Center
Taylor, Elizabeth A.; Hardin, Robin; Rode, Cheryl R.
2018-01-01
Sexual harassment and incivility in the workplace are the unwanted sexual attention and bullying of employees by their superior. There are times, however, when the roles are reversed and the superior is the target of such behavior. Contrapower harassment refers to subordinate incivility and/or sexual attention directed toward a superior. The focus…
WE-AB-209-08: Novel Beam-Specific Adaptive Margins for Reducing Organ-At-Risk Doses
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tsang, H; Kamerling, CP; Ziegenhein, P
2016-06-15
Purpose: Current practice of using 3D margins in radiotherapy with high-energy photon beams provides larger-than-required target coverage. According to the photon depth-dose curve, target displacements in beam direction result in minute changes in dose delivered. We exploit this behavior by generating margins on a per-beam basis which simultaneously account for the relative distance of the target and adjacent organs-at-risk (OARs). Methods: For each beam, we consider only geometrical uncertainties of the target location perpendicular to beam direction. By weighting voxels based on its proximity to an OAR, we generate adaptive margins that yield similar overall target coverage probability and reducedmore » OAR dose-burden, at the expense of increased target volume. Three IMRT plans, using 3D margins and 2D per-beam margins with and without adaptation, were generated for five prostate patients with a prescription dose Dpres of 78Gy in 2Gy fractions using identical optimisation constraints. Systematic uncertainties of 1.1, 1.1, 1.5mm in the LR, SI, and AP directions, respectively, and 0.9, 1.1, 1.0mm for the random uncertainties, were assumed. A verification tool was employed to simulate the effects of systematic and random errors using a population size of 50,000. The fraction of the population that satisfies or violates a given DVH constraint was used for comparison. Results: We observe similar target coverage across all plans, with at least 97.5% of the population meeting the D98%>95%Dpres constraint. When looking at the probability of the population receiving D5<70Gy for the rectum, we observed median absolute increases of 23.61% (range, 2.15%–27.85%) and 6.97% (range, 0.65%–17.76%) using per-beam margins with and without adaptation, respectively, relative to using 3D margins. Conclusion: We observed sufficient and similar target coverage using per-beam margins. By adapting each per-beam margin away from an OAR, we can further reduce OAR dose without significantly lowering target coverage probability by irradiating more less-important tissues. This work is supported by Cancer Research UK under Programme C33589/A19908. Research at ICR is also supported by Cancer Research UK under Programme C33589/A19727 and NHS funding to the NIHR Biomedical Research Centre at RMH and ICR.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Quirk, S; Conroy, L; Smith, WL
Partial breast irradiation (PBI) following breast-conserving surgery is emerging as an effective means to achieve local control and reduce irradiated breast volume. Patients are planned on a static CT image; however, treatment is delivered while the patient is free-breathing. Respiratory motion can degrade plan quality by reducing target coverage and/or dose homogeneity. A variety of methods can be used to determine the required margin for respiratory motion in PBI. We derive geometric and dosimetric respiratory 1D margin. We also verify the adequacy of the typical 5 mm respiratory margin in 3D by evaluating plan quality for increasing respiratory amplitudes (2–20more » mm). Ten PBI plans were used for dosimetric evaluation. A database of volunteer respiratory data, with similar characteristics to breast cancer patients, was used for this study. We derived a geometric 95%-margin of 3 mm from the population respiratory data. We derived a dosimetric 95%-margin of 2 mm by convolving 1D dose profiles with respiratory probability density functions. The 5 mm respiratory margin is possibly too large when 1D coverage is assessed and could lead to unnecessary normal tissue irradiation. Assessing margins only for coverage may be insufficient; 3D dosimetric assessment revealed degradation in dose homogeneity is the limiting factor, not target coverage. Hotspots increased even for the smallest respiratory amplitudes, while target coverage only degraded at amplitudes greater than 10 mm. The 5 mm respiratory margin is adequate for coverage, but due to plan quality degradation, respiratory management is recommended for patients with respiratory amplitudes greater than 10 mm.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sonier, Marcus, E-mail: Marcus.Sonier@bccancer.bc.ca; Chu, William; Department of Radiation Oncology, University of Toronto, Toronto, ON
To develop a volumetric modulated arc therapy (VMAT) treatment planning solution in the treatment of primary renal cell carcinoma and oligometastatic adrenal lesions with stereotactic body radiation therapy. Single-arc VMAT plans (n = 5) were compared with clinically delivered step-and-shoot intensity-modulated radiotherapy (IMRT) with planning target volume coverage normalized between techniques. Target volume conformity, organ-at-risk (OAR) dose, treatment time, and monitor units were compared. A VMAT planning solution, created from a combination of arc settings and optimization constraints, auto-generated treatment plans in a single optimization. The treatment planning solution was evaluated on 15 consecutive patients receiving kidney and adrenal stereotacticmore » body radiation therapy. Treatment time was reduced from 13.0 ± 2.6 to 4.0 ± 0.9 minutes for IMRT and VMAT, respectively. The VMAT planning solution generated treatment plans with increased target homogeneity, improved 95% conformity index, and a reduced maximum point dose to nearby OARs but with increased intermediate dose to distant OARs. The conformity of the 95% isodose improved from 1.32 ± 0.39 to 1.12 ± 0.05 for IMRT and VMAT treatment plans, respectively. Evaluation of the planning solution showed clinically acceptable dose distributions for 13 of 15 cases with tight conformity of the prescription isodose to the planning target volume of 1.07 ± 0.04, delivering minimal dose to OARs. The introduction of a stereotactic body radiation therapy VMAT treatment planning solution improves the efficiency of planning and delivery time, producing treatment plans of comparable or superior quality to IMRT in the case of primary renal cell carcinoma and oligometastatic adrenal lesions.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kusters, Johannes M.A.M.; Louwe, Rob J.W.; Kollenburg, Peter G.M. van
2011-12-01
Purpose: To develop a treatment technique for craniospinal irradiation using intensity-modulated radiotherapy (IMRT) with improved dose homogeneity at the field junction(s), increased target volume conformity, and minimized dose to the organs at risk (OARs). Methods and Materials: Five patients with high-risk medulloblastoma underwent CT simulation in supine position. For each patient, an IMRT plan with daily intrafractionally modulated junction(s) was generated, as well as a treatment plan based on conventional three-dimensional planning (3DCRT). A dose of 39.6 Gy in 22 daily fractions of 1.8 Gy was prescribed. Dose-volume parameters for target volumes and OARs were compared for the two techniques.more » Results: The maximum dose with IMRT was <107% in all patients. V{sub <95} and V{sub >107} were <1 cm{sup 3} for IMRT compared with 3-9 cm{sup 3} for the craniospinal and 26-43 cm{sup 3} for the spinal-spinal junction with 3DCRT. These observations corresponded with a lower homogeneity index and a higher conformity index for the spinal planning target volume with IMRT. IMRT provided considerable sparing of acute and late reacting tissues. V{sub 75} for the esophagus, gastroesophageal junction, and intestine was 81%, 81%, and 22% with 3DCRT versus 5%, 0%, and 1% with IMRT, respectively. V{sub 75} for the heart and thyroid was 42% and 32% vs. 0% with IMRT. Conclusion: IMRT with daily intrafractionally modulated junction results in a superior target coverage and junction homogeneity compared with 3DCRT. A significant dose reduction can be obtained for acute as well as late-reacting tissues.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Parhar, Preeti K.; Duckworth, Tamara; Shah, Parinda
2010-10-01
Purpose: To compare temporal lobe dose delivered by three pituitary macroadenoma irradiation techniques: three-field three-dimensional conformal radiotherapy (3D-CRT), three-field intensity-modulated radiotherapy (3F IMRT), and a proposed novel alternative of five-field IMRT (5F IMRT). Methods and Materials: Computed tomography-based external beam radiotherapy planning was performed for 15 pituitary macroadenoma patients treated at New York University between 2002 and 2007 using: 3D-CRT (two lateral, one midline superior anterior oblique [SAO] beams), 3F IMRT (same beam angles), and 5F IMRT (same beam angles with additional right SAO and left SAO beams). Prescription dose was 45 Gy. Target volumes were: gross tumor volume (GTV)more » = macroadenoma, clinical target volume (CTV) = GTV, and planning target volume = CTV + 0.5 cm. Structure contouring was performed by two radiation oncologists guided by an expert neuroradiologist. Results: Five-field IMRT yielded significantly decreased temporal lobe dose delivery compared with 3D-CRT and 3F IMRT. Temporal lobe sparing with 5F IMRT was most pronounced at intermediate doses: mean V25Gy (% of total temporal lobe volume receiving {>=}25 Gy) of 13% vs. 28% vs. 29% for right temporal lobe and 14% vs. 29% vs. 30% for left temporal lobe for 5F IMRT, 3D-CRT, and 3F IMRT, respectively (p < 10{sup -7} for 5F IMRT vs. 3D-CRT and 5F IMRT vs. 3F IMRT). Five-field IMRT plans did not compromise target coverage, exceed normal tissue dose constraints, or increase estimated brain integral dose. Conclusions: Five-field IMRT irradiation technique results in a statistically significant decrease in the dose to the temporal lobes and may thus help prevent neurocognitive sequelae in irradiated pituitary macroadenoma patients.« less
Financial incentives to encourage healthy behaviour: an analysis of U.K. media coverage.
Parke, Hannah; Ashcroft, Richard; Brown, Rebecca; Marteau, Theresa M; Seale, Clive
2013-09-01
Policies to use financial incentives to encourage healthy behaviour are controversial. Much of this controversy is played out in the mass media, both reflecting and shaping public opinion. To describe U.K. mass media coverage of incentive schemes, comparing schemes targeted at different client groups and assessing the relative prominence of the views of different interest groups. Thematic content analysis. National and local news coverage in newspapers, news media targeted at health-care providers and popular websites between January 2005 and February 2010. U.K. mass media. The study included 210 articles. Fifteen separate arguments favourable towards schemes, and 19 unfavourable, were identified. Overall, coverage was more favourable than unfavourable, although most articles reported a mix of views. Arguments about the prevalence and seriousness of the health problems targeted by incentive schemes were uncontested. Moral and ethical objections to such schemes were common, focused in particular on recipients such as drug users or the overweight who were already stereotyped as morally deficient, and these arguments were largely uncontested. Arguments about the effectiveness of schemes and their potential for benefit or harm were areas of greater contestation. Government, public health and other health-care provider interests dominated favourable coverage; opposition came from rival politicians, taxpayers' representatives, certain charities and from some journalists themselves. Those promoting incentive schemes for people who might be regarded as 'undeserving' should plan a media strategy that anticipates their public reception. © 2011 John Wiley & Sons Ltd.
Financial incentives to encourage healthy behaviour: an analysis of UK media coverage
Parke, Hannah; Ashcroft, Richard; Brown, Rebecca; Marteau, Theresa M; Seale, Clive
2011-01-01
Abstract Background Policies to use financial incentives to encourage healthy behaviour are controversial. Much of this controversy is played out in the mass media, both reflecting and shaping public opinion. Objective To describe UK mass media coverage of incentive schemes, comparing schemes targeted at different client groups and assessing the relative prominence of the views of different interest groups. Design Thematic content analysis. Subjects National and local news coverage in newspapers, news media targeted at health‐care providers and popular websites between January 2005 and February 2010. Setting UK mass media. Results The study included 210 articles. Fifteen separate arguments favourable towards schemes, and 19 unfavourable, were identified. Overall, coverage was more favourable than unfavourable, although most articles reported a mix of views. Arguments about the prevalence and seriousness of the health problems targeted by incentive schemes were uncontested. Moral and ethical objections to such schemes were common, focused in particular on recipients such as drug users or the overweight who were already stereotyped as morally deficient, and these arguments were largely uncontested. Arguments about the effectiveness of schemes and their potential for benefit or harm were areas of greater contestation. Government, public health and other health‐care provider interests dominated favourable coverage; opposition came from rival politicians, taxpayers’ representatives, certain charities and from some journalists themselves. Conclusions Those promoting incentive schemes for people who might be regarded as ‘undeserving’ should plan a media strategy that anticipates their public reception. PMID:21771227
NASA Astrophysics Data System (ADS)
Bejarano Buele, Ana Isabel
The treatment regimen for breast cancer patients typically involves Whole Breast Irradiation (WBI). The coverage and extent of the radiation treatment is dictated by location of tumor mass, breast tissue distribution, involvement of lymph nodes, and other factors. The current standard treatment approach used at our institution is a 3D tangential beam geometry, which involves two fields irradiating the breast, or a four field beam arrangement covering the whole breast and involved nodes, while decreasing the dose to organs as risk (OARs) such as the lung and heart. The coverage of these targets can be difficult to achieve in patients with unfavorable thoracic geometries, especially in those cases in which the planning target volume (PTV) is extended to the chest wall. It is a well-known fact that exposure of the heart to ionizing radiation has been proved to increase the subsequent rate of ischemic heart disease. In these cases, inverse planned treatments have become a proven alternative to the 3D approach. The goal of this research project is to evaluate the factors that affect our current techniques as well as to adapt the development of inverse modulated techniques for our clinic, in which breast cancer patients are one of the largest populations treated. For this purpose, a dosimetric comparison along with the evaluation of immobilization devices was necessary. Radiation treatment plans were designed and dosimetrically compared for 5 patients in both, supine and prone positions. For 8 patients, VMAT and IMRT plans were created and evaluated in the supine position. Skin flash incorporation for inverse modulated plans required measurement of the surface dose as well as an evaluation of breast volume changes during a treatment course. It was found that prone 3D conformal plans as well as the VMAT and IMRT plans are generally superior in sparing OARs to supine plans with comparable PTV coverage. Prone setup leads to larger shifts in breast volume as well as in positioning due to the difference in target geometry and nature of the immobilization device. IMRT and VMAT plans offer sparing of OARs from high dose regions with an increase of irradiated volume in the low dose regions. Skin flash incorporation was found to be accurate with the use of virtual bolus in the TPS for inverse modulated plans. Various factors influencing dose delivery in breast cancer radiation treatments were examined and quantified. Practical recommendations developed in the course of this project can improve our current techniques and provide alternatives to treat unique and challenging clinical cases.
Gerlier, Laetitia; Lamotte, Mark; Dos Santos Mendes, Sofia; Damm, Oliver; Schwehm, Markus; Eichner, Martin
2016-08-01
Our objectives were to estimate the public health outcomes of vaccinating Belgian children using an intranasal tetravalent live-attenuated influenza vaccine (QLAIV) combined with current coverage of high-risk/elderly individuals using the trivalent inactivated vaccine. We used a deterministic, age-structured, dynamic model to simulate seasonal influenza transmission in the Belgian population under the current coverage or after extending vaccination with QLAIV to healthy children aged 2-17 years. Differential equations describe demographic changes, exposure to infectious individuals, infection recovery, and immunity dynamics. The basic reproduction number (R 0) was calibrated to the observed number of influenza doctor visits/year. Vaccine efficacy was 80 % (live-attenuated) and 59-68 % (inactivated). The 10-year incidence of symptomatic influenza was calculated with different coverage scenarios (add-on to current coverage). Model calibration yielded R 0 = 1.1. QLAIV coverage of 75 % of those aged 2-17 years averted 374,000 symptomatic cases/year (57 % of the current number), 244,000 of which were among adults (indirect effect). Vaccinating 75 % of those aged 2-11 years and 50 % of those aged 12-17 years averted 333,200 cases/year (213,000 adult cases/year). Vaccinating only healthy children aged 2-5 years generated direct protection but limited indirect protection, even with 90 % coverage (40,800 averted adult cases/year; -8.4 %). Targeting all children averted twice as many high-risk cases as targeting high-risk children only (8485 vs. 4965/year with 75 % coverage). Sensitivity analyses showed the robustness of results. The model highlights the direct and indirect protection benefits when vaccinating healthy children with QLAIV in Belgium. Policies targeting only high-risk individuals or the youngest provide limited herd protection, as school-age children are important influenza vectors in the community.
Yock, Adam D; Kim, Gwe-Ya
2017-09-01
To present the k-means clustering algorithm as a tool to address treatment planning considerations characteristic of stereotactic radiosurgery using a single isocenter for multiple targets. For 30 patients treated with stereotactic radiosurgery for multiple brain metastases, the geometric centroids and radii of each met were determined from the treatment planning system. In-house software used this as well as weighted and unweighted versions of the k-means clustering algorithm to group the targets to be treated with a single isocenter, and to position each isocenter. The algorithm results were evaluated using within-cluster sum of squares as well as a minimum target coverage metric that considered the effect of target size. Both versions of the algorithm were applied to an example patient to demonstrate the prospective determination of the appropriate number and location of isocenters. Both weighted and unweighted versions of the k-means algorithm were applied successfully to determine the number and position of isocenters. Comparing the two, both the within-cluster sum of squares metric and the minimum target coverage metric resulting from the unweighted version were less than those from the weighted version. The average magnitudes of the differences were small (-0.2 cm 2 and 0.1% for the within cluster sum of squares and minimum target coverage, respectively) but statistically significant (Wilcoxon signed-rank test, P < 0.01). The differences between the versions of the k-means clustering algorithm represented an advantage of the unweighted version for the within-cluster sum of squares metric, and an advantage of the weighted version for the minimum target coverage metric. While additional treatment planning considerations have a large influence on the final treatment plan quality, both versions of the k-means algorithm provide automatic, consistent, quantitative, and objective solutions to the tasks associated with SRS treatment planning using a single isocenter for multiple targets. © 2017 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.
Is universal health coverage the practical expression of the right to health care?
2014-01-01
The present Millennium Development Goals are set to expire in 2015 and their next iteration is now being discussed within the international community. With regards to health, the World Health Organization proposes universal health coverage as a ‘single overarching health goal’ for the next iteration of the Millennium Development Goals. The present Millennium Development Goals have been criticised for being ‘duplicative’ or even ‘competing alternatives’ to international human rights law. The question then arises, if universal health coverage would indeed become the single overarching health goal, replacing the present health-related Millennium Development Goals, would that be more consistent with the right to health? The World Health Organization seems to have anticipated the question, as it labels universal health coverage as “by definition, a practical expression of the concern for health equity and the right to health”. Rather than waiting for the negotiations to unfold, we thought it would be useful to verify this contention, using a comparative normative analysis. We found that – to be a practical expression of the right to health – at least one element is missing in present authoritative definitions of universal health coverage: a straightforward confirmation that international assistance is essential, not optional. But universal health coverage is a ‘work in progress’. A recent proposal by the United Nations Sustainable Development Solutions Network proposed universal health coverage with a set of targets, including a target for international assistance, which would turn universal health coverage into a practical expression of the right to health care. PMID:24559232
Reliability of Fault Tolerant Control Systems. Part 2
NASA Technical Reports Server (NTRS)
Wu, N. Eva
2000-01-01
This paper reports Part II of a two part effort that is intended to delineate the relationship between reliability and fault tolerant control in a quantitative manner. Reliability properties peculiar to fault-tolerant control systems are emphasized, such as the presence of analytic redundancy in high proportion, the dependence of failures on control performance, and high risks associated with decisions in redundancy management due to multiple sources of uncertainties and sometimes large processing requirements. As a consequence, coverage of failures through redundancy management can be severely limited. The paper proposes to formulate the fault tolerant control problem as an optimization problem that maximizes coverage of failures through redundancy management. Coverage modeling is attempted in a way that captures its dependence on the control performance and on the diagnostic resolution. Under the proposed redundancy management policy, it is shown that an enhanced overall system reliability can be achieved with a control law of a superior robustness, with an estimator of a higher resolution, and with a control performance requirement of a lesser stringency.
Terahertz quantum-cascade lasers as high-power and wideband, gapless sources for spectroscopy.
Röben, Benjamin; Lü, Xiang; Hempel, Martin; Biermann, Klaus; Schrottke, Lutz; Grahn, Holger T
2017-07-10
Terahertz (THz) quantum-cascade lasers (QCLs) are powerful radiation sources for high-resolution and high-sensitivity spectroscopy with a discrete spectrum between 2 and 5 THz as well as a continuous coverage of several GHz. However, for many applications, a radiation source with a continuous coverage of a substantially larger frequency range is required. We employed a multi-mode THz QCL operated with a fast ramped injection current, which leads to a collective tuning of equally-spaced Fabry-Pérot laser modes exceeding their separation. A continuous coverage over 72 GHz at about 4.7 THz was achieved. We demonstrate that the QCL is superior to conventional sources used in Fourier transform infrared spectroscopy in terms of the signal-to-noise ratio as well as the dynamic range by one to two orders of magnitude. Our results pave the way for versatile THz spectroscopic systems with unprecedented resolution and sensitivity across a wide frequency range.
The web and public confidence in MMR vaccination in Italy.
Aquino, Francesco; Donzelli, Gabriele; De Franco, Emanuela; Privitera, Gaetano; Lopalco, Pier Luigi; Carducci, Annalaura
2017-08-16
Measles, mumps and rubella (MMR) vaccination coverage in Italy has been decreasing starting from 2012 and, at the present, none of the Italian regions has achieved the goal of 95% coverage target. A decision of the Court of Justice of Rimini in March 2012 that awarded vaccine-injury compensation for a case of autism has been indicated as a probable trigger event leading to a reduction of vaccine confidence in Italy. The aim of the study was to explore the relationship between MMR vaccination coverage to online search trends and social network activity on the topic "autism and MMR vaccine", during the period 2010-2015. A significant inverse correlation was found between MMR vaccination coverage and Internet search activity, tweets and Facebook posts. New media might have played a role in spreading misinformation. Media monitoring could be useful to assess the level of vaccine hesitancy and to plan and target effective information campaigns. Copyright © 2017 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Meyer, Jeff, E-mail: jmeye3@utsouthwestern.ed; Bluett, Jaques; Amos, Richard
Purpose: Conventional proton therapy with passively scattered beams is used to treat a number of tumor sites, including prostate cancer. Spot scanning proton therapy is a treatment delivery means that improves conformal coverage of the clinical target volume (CTV). Placement of individual spots within a target is dependent on traversed tissue density. Errors in patient alignment perturb dose distributions. Moreover, there is a need for a rational planning approach that can mitigate the dosimetric effect of random alignment errors. We propose a treatment planning approach and then analyze the consequences of various simulated alignment errors on prostate treatments. Methods andmore » Materials: Ten control patients with localized prostate cancer underwent treatment planning for spot scanning proton therapy. After delineation of the clinical target volume, a scanning target volume (STV) was created to guide dose coverage. Errors in patient alignment in two axes (rotational and yaw) as well as translational errors in the anteroposterior direction were then simulated, and dose to the CTV and normal tissues were reanalyzed. Results: Coverage of the CTV remained high even in the setting of extreme rotational and yaw misalignments. Changes in the rectum and bladder V45 and V70 were similarly minimal, except in the case of translational errors, where, as a result of opposed lateral beam arrangements, much larger dosimetric perturbations were observed. Conclusions: The concept of the STV as applied to spot scanning radiation therapy and as presented in this report leads to robust coverage of the CTV even in the setting of extreme patient misalignments.« less
Osei, Ernest; Barnett, Rob
2015-01-01
The aim of this study is to provide guidelines for the selection of external‐beam radiation therapy target margins to compensate for target motion in the lung during treatment planning. A convolution model was employed to predict the effect of target motion on the delivered dose distribution. The accuracy of the model was confirmed with radiochromic film measurements in both static and dynamic phantom modes. 502 unique patient breathing traces were recorded and used to simulate the effect of target motion on a dose distribution. A 1D probability density function (PDF) representing the position of the target throughout the breathing cycle was generated from each breathing trace obtained during 4D CT. Changes in the target D95 (the minimum dose received by 95% of the treatment target) due to target motion were analyzed and shown to correlate with the standard deviation of the PDF. Furthermore, the amount of target D95 recovered per millimeter of increased field width was also shown to correlate with the standard deviation of the PDF. The sensitivity of changes in dose coverage with respect to target size was also determined. Margin selection recommendations that can be used to compensate for loss of target D95 were generated based on the simulation results. These results are discussed in the context of clinical plans. We conclude that, for PDF standard deviations less than 0.4 cm with target sizes greater than 5 cm, little or no additional margins are required. Targets which are smaller than 5 cm with PDF standard deviations larger than 0.4 cm are most susceptible to loss of coverage. The largest additional required margin in this study was determined to be 8 mm. PACS numbers: 87.53.Bn, 87.53.Kn, 87.55.D‐, 87.55.Gh
Kripke, Katharine; Samuelson, Julia; Schnure, Melissa; Dalal, Shona; Farley, Timothy; Hankins, Catherine; Thomas, Anne G.; Reed, Jason; Stegman, Peter; Bock, Naomi
2016-01-01
Background In 2007, the World Health Organization and the Joint United Nations Programme on HIV/AIDS (UNAIDS) identified 14 priority countries across eastern and southern Africa for scaling up voluntary medical male circumcision (VMMC) services. Several years into this effort, we reflect on progress. Methods Using the Decision Makers’ Program Planning Tool (DMPPT) 2.1, we assessed age-specific impact, cost-effectiveness, and coverage attributable to circumcisions performed through 2014. We also compared impact of actual progress to that of achieving 80% coverage among men ages 15–49 in 12 VMMC priority countries and Nyanza Province, Kenya. We populated the models with age-disaggregated VMMC service statistics and with population, mortality, and HIV incidence and prevalence projections exported from country-specific Spectrum/Goals files. We assumed each country achieved UNAIDS’ 90-90-90 treatment targets. Results More than 9 million VMMCs were conducted through 2014: 43% of the estimated 20.9 million VMMCs required to reach 80% coverage by the end of 2015. The model assumed each country reaches the UNAIDS targets, and projected that VMMCs conducted through 2014 will avert 240,000 infections by the end of 2025, compared to 1.1 million if each country had reached 80% coverage by the end of 2015. The median estimated cost per HIV infection averted was $4,400. Nyanza Province in Kenya, the 11 priority regions in Tanzania, and Uganda have reached or are approaching MC coverage targets among males ages 15–24, while coverage in other age groups is lower. Across all countries modeled, more than half of the projected HIV infections averted were attributable to circumcising 10- to 19-year-olds. Conclusions The priority countries have made considerable progress in VMMC scale-up, and VMMC remains a cost-effective strategy for epidemic impact, even assuming near-universal HIV diagnosis, treatment coverage, and viral suppression. Examining circumcision coverage by five-year age groups will inform countries’ decisions about next steps. PMID:27441648
Evaluation of the New MALDI Matrix 4-Chloro-α-Cyanocinnamic Acid
Leszyk, John D.
2010-01-01
MALDI-TOF continues to be an important tool for many proteomic studies. Recently, a new rationally designed matrix 4-chloro-α-cyanocinnamic acid was introduced, which is reported to have superior performance as compared with the “gold standard” α-cyano-4-hydroxycinnamic acid (CHCA).1 In this study, the performance of this new matrix, using the Shimadzu Biotech Axima TOF2 (Shimadzu Biotech, Manchester, UK), was investigated. The overall sequence coverage as well as sensitivity of this matrix were compared with CHCA using standard protein tryptic digests. The performance of this matrix with labile peptides, such as phosphopeptides and 4-sulfophenyl isothiocynate-derivatized peptides, to facilitate de novo sequencing was also explored. This matrix was found to be better performing than CHCA in overall sensitivity and showed better sequence coverage at low-digest levels, partly as a result of less of a bias for arginine-containing peptides. It also showed as much as a tenfold improvement in sensitivity with labile peptides on standard stainless-steel targets. In addition, as a result of the much cooler nature of this matrix, labile peptides are readily seen intact with much less fragmentation in mass spectrometry (MS) mode. This matrix was also evaluated in the MS/MS fragmentation modes of post-source decay (PSD) and collisional-induced dissociation (CID). It was found that fragmentation occurs readily in CID, however as a result of the very cool nature of this new matrix, the PSD fragments were quite weak. This matrix promises to be an important addition to the already extensive array of MALDI matrices. PMID:20592871
Kamran, Sophia C; Mueller, Birgit S; Paetzold, Peter; Dunlap, Joseph; Niemierko, Andrzej; Bortfeld, Thomas; Willers, Henning; Craft, David
2016-03-01
In this planning study, we studied the benefit of intensity-modulated radiation therapy (IMRT) with multi-criteria optimization (MCO) in locally advanced non-small cell lung carcinoma (NSCLC). We selected 10 consecutive patients with gross tumor within 1cm of the esophagus eligible for RTOG 1308, randomized phase II trial of 70 Gy protons vs photons. Planning was performed per protocol. In addition, a novel approach for esophagus sparing was applied by making the contralateral esophagus (CE) an avoidance structure. MCO and non-MCO plans underwent double-blinded review. Plan differences in dose-volume histogram parameters were analyzed. Median plan differences were mean lung dose=0.8 Gy (p=0.01), lung V20=1.1% (p=0.06), heart V30=1.0% (p=0.03), heart V45=0.6% (p=0.03), esophagus V60=1.2% (p=0.04), and CE V45=3.2% (p=0.01), all favoring MCO over non-MCO. PTV coverage with 95% dose was ⩾98.0% for both plans. There were 5 minor protocol deviations with non-MCO plans and 2 with MCO. Median improvement of active planning time with MCO was 88 min (p<0.01). Physicians preferred 8 MCO and 2 non-MCO plans (p=0.04). MCO plans yielded significant improvements in organ-at-risk sparing without compromising target coverage, consumed less dosimetrist time, and were preferred by physicians. We suggest incorporating MCO into prospective clinical trials. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
The 5As: A practical taxonomy for the determinants of vaccine uptake.
Thomson, Angus; Robinson, Karis; Vallée-Tourangeau, Gaëlle
2016-02-17
Suboptimal vaccine uptake in both childhood and adult immunisation programs limits their full potential impact on global health. A recent progress review of the Global Vaccine Action Plan stated that "countries should urgently identify barriers and bottlenecks and implement targeted approaches to increase and sustain coverage". However, vaccination coverage may be determined by a complex mix of demographic, structural, social and behavioral factors. To develop a practical taxonomy to organise the myriad possible root causes of a gap in vaccination coverage rates, we performed a narrative review of the literature and tested whether all non-socio-demographic determinants of coverage could be organised into 4 dimensions: Access, Affordability, Awareness and Acceptance. Forty-three studies were reviewed, from which we identified 23 primary determinants of vaccination uptake. We identified a fifth domain, Activation, which captured interventions such as SMS reminders which effectively nudge people towards getting vaccinated. The 5As taxonomy captured all identified determinants of vaccine uptake. This intuitive taxonomy has already facilitated mutual understanding of the primary determinants of suboptimal coverage within inter-sectorial working groups, a first step towards them developing targeted and effective solutions. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.
de Figueiredo, Alexandre; Johnston, Iain G; Smith, David M D; Agarwal, Sumeet; Larson, Heidi J; Jones, Nick S
2016-10-01
Incomplete immunisation coverage causes preventable illness and death in both developing and developed countries. Identification of factors that might modulate coverage could inform effective immunisation programmes and policies. We constructed a performance indicator that could quantitatively approximate measures of the susceptibility of immunisation programmes to coverage losses, with an aim to identify correlations between trends in vaccine coverage and socioeconomic factors. We undertook a data-driven time-series analysis to examine trends in coverage of diphtheria, tetanus, and pertussis (DTP) vaccination across 190 countries over the past 30 years. We grouped countries into six world regions according to WHO classifications. We used Gaussian process regression to forecast future coverage rates and provide a vaccine performance index: a summary measure of the strength of immunisation coverage in a country. Overall vaccine coverage increased in all six world regions between 1980 and 2010, with variation in volatility and trends. Our vaccine performance index identified that 53 countries had more than a 50% chance of missing the Global Vaccine Action Plan (GVAP) target of 90% worldwide coverage with three doses of DTP (DTP3) by 2015. These countries were mostly in sub-Saharan Africa and south Asia, but Austria and Ukraine also featured. Factors associated with DTP3 immunisation coverage varied by world region: personal income (Spearman's ρ=0·66, p=0·0011) and government health spending (0·66, p<0·0001) were informative of immunisation coverage in the Eastern Mediterranean between 1980 and 2010, whereas primary school completion was informative of coverage in Africa (0·56, p<0·0001) over the same period. The proportion of births attended by skilled health staff correlated significantly with immunisation coverage across many world regions. Our vaccine performance index highlighted countries at risk of failing to achieve the GVAP target of 90% coverage by 2015, and could aid policy makers' assessments of the strength and resilience of immunisation programmes. Weakening correlations with socioeconomic factors show a need to tackle vaccine confidence, whereas strengthening correlations point to clear factors to address. UK Engineering and Physical Sciences Research Council. Copyright © 2016 The Author(s). Published by Elsevier Ltd. This is an Open Access article under the CC BY license. Published by Elsevier Ltd.. All rights reserved.
The role of helical tomotherapy in the treatment of bone plasmacytoma.
Chargari, Cyrus; Hijal, Tarek; Bouscary, Didier; Caussa, Lucas; Dendale, Remi; Zefkili, Sofia; Fourquet, Alain; Kirova, Youlia M
2012-01-01
We evaluated the early clinical outcome of patients with solitary bone plasmacytoma (SP) or a solitary lesion of multiple myeloma (MM) treated with helical tomotherapy (HT) compared with 3D conformal radiotherapy (3D-CRT), in terms of target coverage and exposure of critical organs. Ten patients with SP and 3 patients with a solitary lesion of MM underwent radiation therapy (RT) delivered by HT, to a dose of 40 Gy in 20 fractions. Treatment planning was then performed with 3D-CRT and the dosimetric parameters of both techniques were compared. Patients were also assessed for response to treatment and acute toxicities. With a median follow-up of 13 months, 78% of patients with pain before RT had resolution of their symptoms. Coverage of target lesion was adequate with both techniques in 12 of 13 patients. Target coverage was significantly lower for HT (V(95%) = 98.55% vs. 97.15%; p = 0.04, for 3D-CRT and HT, respectively). Target overdoses were also lower with HT (V(105%) = 2.01% vs. 0.19%; p= 0.16), although nonsignificant. Finally, there were no significant differences in organs-at-risk irradiation between both techniques. The early treatment tolerance was excellent, with no toxicity higher than grade I. RT of SP and MM with a solitary lesion can be safely delivered with HT, with no major acute side effects and good symptomatic control. Finally, HT provides a dosimetry similar to that of 3D-CRT in terms of organs-at-risk sparing and target volume coverage. Copyright © 2012 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.
Mansoor, Ali; Ramzan, Amaila; Chaudhary, Aamer Nadeem
2017-04-01
light of recommendations of ACR. Aclinical audit. Department of Radiology, Jinnah Hospital, Lahore, from August 2015 to February 2016. Scans of 20 patients who underwent MRI of knee in August 2015 were studied retrospectively to assess the quality of images obtained in the first audit. Based on the findings of this audit, recommendations were made and re audit was done 6 months later in February 2016 to look for improvement in local practice. In the first audit, images were acquired in all the three necessary planes and the sagittal and coronal images had appropriate slice thickness, interslice gap as well as adequate anatomical coverage in all the patients. However, FOV (field of view) was appropriately set in 66% of cases in axial plane, 5% in sagittal plane, and 0% in coronal plane. Also, the anatomical coverage was not upto the mark in axial plane with 13 studies (66%) having adequate superior coverage, and 16 cases (80%) having recommended inferior anatomical coverage. The re audit performed 6 months later showed improvement with 100% compliance to standards. The first audit showed many shortcomings in acquiring of MRI data in patients undergoing knee MRI with FOV requiring a decrease in all planes and anatomical coverage increase in axial plane. These recommendations were made in departmental meetings and re-audit was done after 6 months. This second audit showed 100 % compliance.
Jepsen, Karin; Jepsen, Søren; Zucchelli, Giovanni; Stefanini, Martina; de Sanctis, Massimo; Baldini, Nicola; Greven, Björn; Heinz, Bernd; Wennström, Jan; Cassel, Björn; Vignoletti, Fabio; Sanz, Mariano
2013-01-01
To evaluate the clinical outcomes of the use of a xenogeneic collagen matrix (CM) in combination with the coronally advanced flap (CAF) in the treatment of localized recession defects. In a multicentre single-blinded, randomized, controlled, split-mouth trial, 90 recessions (Miller I, II) in 45 patients received either CAF + CM or CAF alone. At 6 months, root coverage (primary outcome) was 75.29% for test and 72.66% for control defects (p = 0.169), with 36% of test and 31% of control defects exhibiting complete coverage. The increase in mean width of keratinized tissue (KT) was higher in test (from 1.97 to 2.90 mm) than in control defects (from 2.00 to 2.57 mm) (p = 0.036). Likewise, test sites had more gain in gingival thickness (GT) (0.59 mm) than control sites (0.34 mm) (p = 0.003). Larger (≥3 mm) recessions (n = 35 patients) treated with CM showed higher root coverage (72.03% versus 66.16%, p = 0.043), as well as more gain in KT and GT. CAF + CM was not superior with regard to root coverage, but enhanced gingival thickness and width of keratinized tissue when compared with CAF alone. For the coverage of larger defects, CAF + CM was more effective. © 2012 John Wiley & Sons A/S.
Seeking consensus on universal health coverage indicators in the sustainable development goals.
Reddock, Jennifer
2017-01-01
There is optimism that the inclusion of universal health coverage in the Sustainable Development Goals advances its prominence in global and national health policy. However, formulating indicators for Target 3.8 through the Inter-Agency Expert Group on Sustainable Development Indicators has been challenging. Achieving consensus on the conceptual and methodological aspects of universal health coverage is likely to take some time in multi-stakeholder fora compared with national efforts to select indicators.
The influence of performance-based payment on childhood immunisation coverage.
Merilind, Eero; Salupere, Rauno; Västra, Katrin; Kalda, Ruth
2015-06-01
Pay-for-performance, also called the quality system (QS) in Estonia, was implemented in 2006 and one indicator for achievement is the childhood immunisation coverage rate. The WHO vaccination coverage in Europe for diphtheria, tetanus and pertussis, and measles in children aged around one year old should meet or exceed 90 per cent. The study was conducted using a database from the Estonian Health Insurance Fund. The study compared childhood immunisation coverage rates of all Estonian family physicians in two groups, joined and not joined to the quality system during the observation period 2006-2012. Immunisation coverage was calculated as the percentage of persons in the target age group who received a vaccine dose by a given age. The target level of immunisations in Estonia is set at 90 per cent and higher. Immunisation coverage rates of family doctors (FD) in Estonia showed significant differences between two groups of doctors: joined to the quality system and not joined. Doctors joined to the quality system met the 90 per cent vaccination criterion more frequently compared to doctors not joined to the quality system. Doctors not joined to the quality system were below the 90 per cent vaccination criterion in all vaccinations listed in the Estonian State Immunisation Schedule. Pay-for-performance as a financial incentive encourages higher levels of childhood immunisations. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yu, Yao; Chen, Josephine; Leary, Celeste I.
Radiation of the low neck can be accomplished using split-field intensity-modulated radiation therapy (sf-IMRT) or extended-field intensity-modulated radiation therapy (ef-IMRT). We evaluated the effect of these treatment choices on target coverage and thyroid and larynx doses. Using data from 14 patients with cancers of the oropharynx, we compared the following 3 strategies for radiating the low neck: (1) extended-field IMRT, (2) traditional split-field IMRT with an initial cord-junction block to 40 Gy, followed by a full-cord block to 50 Gy, and (3) split-field IMRT with a full-cord block to 50 Gy. Patients were planned using each of these 3 techniques.more » To facilitate comparison, extended-field plans were normalized to deliver 50 Gy to 95% of the neck volume. Target coverage was assessed using the dose to 95% of the neck volume (D{sub 95}). Mean thyroid and larynx doses were computed. Extended-field IMRT was used as the reference arm; the mean larynx dose was 25.7 ± 7.4 Gy, and the mean thyroid dose was 28.6 ± 2.4 Gy. Split-field IMRT with 2-step blocking reduced laryngeal dose (mean larynx dose 15.2 ± 5.1 Gy) at the cost of a moderate reduction in target coverage (D{sub 95} 41.4 ± 14 Gy) and much higher thyroid dose (mean thyroid dose 44.7 ± 3.7 Gy). Split-field IMRT with initial full-cord block resulted in greater laryngeal sparing (mean larynx dose 14.2 ± 5.1 Gy) and only a moderately higher thyroid dose (mean thyroid dose 31 ± 8 Gy) but resulted in a significant reduction in target coverage (D{sub 95} 34.4 ± 15 Gy). Extended-field IMRT comprehensively covers the low neck and achieves acceptable thyroid and laryngeal sparing. Split-field IMRT with a full-cord block reduces laryngeal doses to less than 20 Gy and spares the thyroid, at the cost of substantially reduced coverage of the low neck. Traditional 2-step split-field IMRT similarly reduces the laryngeal dose but also reduces low-neck coverage and delivers very high doses to the thyroid.« less
Nkiwane, Karen S; Pötter, Richard; Tanderup, Kari; Federico, Mario; Lindegaard, Jacob C; Kirisits, Christian
2013-01-01
Three-dimensional evaluation and comparison of target and organs at risk (OARs) doses from two traditional standard source loading patterns in the frame of MRI-guided cervical cancer brachytherapy for various clinical scenarios based on patient data collected in a multicenter trial setting. Two nonoptimized three-dimensional MRI-based treatment plans, Plan 1 (tandem and vaginal loading) and Plan 2 (tandem loading only), were generated for 134 patients from seven centers participating in the EMBRACE study. Both plans were normalized to point A (Pt. A). Target and OAR doses were evaluated in terms of minimum dose to 90% of the high-risk clinical target volume (HRCTV D90) grouped by tumor stage and minimum dose to the most exposed 2cm³ of the OARs volume. An HRCTV D90 ≥ Pt. A was achieved in 82% and 44% of the patients with Plans 1 and 2, respectively. Median HRCTV D90 with Plans 1 and 2 was 120% and 90% of Pt. A dose, respectively. Both plans had optimal dose coverage in 88% of Stage IB tumors; however, the tandem-only plan resulted in about 50% of dose reduction to the vagina and rectum. For Stages IIB and IIIB, Plan 1 had on average 35% better target coverage but with significant doses to OARs. Standard tandem loading alone results in good target coverage in most Stage IB tumors without violating OAR dose constraints. For Stage IIB tumors, standard vaginal loading improves the therapeutic window, however needs optimization to fulfill the dose prescription for target and OAR. In Stage IIIB, even optimized vaginal loading often does not fulfill the needs for dose prescription. The significant dose variation across various clinical scenarios for both target and OARs indicates the need for image-guided brachytherapy for optimal dose adaptation both for limited and advanced diseases. Copyright © 2013 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.
Choi, Kyu Hye; Kim, Jina; Lee, Sea-Won; Kang, Young-Nam; Jang, HongSeok
2018-03-01
The objective of this study was to compare dosimetric characteristics of three-dimensional conformal radiotherapy (3D-CRT) and two types of intensity-modulated radiotherapy (IMRT) which are step-and-shoot intensity modulated radiotherapy (s-IMRT) and modulated arc therapy (mARC) for thoracic esophageal cancer and analyze whether IMRT could reduce organ-at-risk (OAR) dose. We performed 3D-CRT, s-IMRT, and mARC planning for ten patients with thoracic esophageal cancer. The dose-volume histogram for each plan was extracted and the mean dose and clinically significant parameters were analyzed. Analysis of target coverage showed that the conformity index (CI) and conformation number (CN) in mARC were superior to the other two plans (CI, p = 0.050; CN, p = 0.042). For the comparison of OAR, lung V 5 was lowest in s-IMRT, followed by 3D-CRT, and mARC (p = 0.033). s-IMRT and mARC had lower values than 3D-CRT for heart V 30 (p = 0.039), V 40 (p = 0.040), and V 50 (p = 0.032). Effective conservation of the lung and heart in thoracic esophageal cancer could be expected when using s-IMRT. The mARC was lower in lung V 10 , V 20 , and V 30 than in 3D-CRT, but could not be proven superior in lung V 5 . In conclusion, low-dose exposure to the lung and heart were expected to be lower in s-IMRT, reducing complications such as radiation pneumonitis or heart-related toxicities.
Cross-National Differences in Special Education Coverage: An Empirical Analysis
ERIC Educational Resources Information Center
Anastasiou, Dimitris; Keller, Clayton E.
2014-01-01
This study investigated the role of educational and socioeconomic factors in explaining differences in national special education coverage. Data were derived from several international and governmental sources, targeting the year 2008 and covering 143 countries. Descriptive statistics revealed huge disparities in access to special education among…
Can linear superiorization be useful for linear optimization problems?
NASA Astrophysics Data System (ADS)
Censor, Yair
2017-04-01
Linear superiorization (LinSup) considers linear programming problems but instead of attempting to solve them with linear optimization methods it employs perturbation resilient feasibility-seeking algorithms and steers them toward reduced (not necessarily minimal) target function values. The two questions that we set out to explore experimentally are: (i) does LinSup provide a feasible point whose linear target function value is lower than that obtained by running the same feasibility-seeking algorithm without superiorization under identical conditions? (ii) How does LinSup fare in comparison with the Simplex method for solving linear programming problems? Based on our computational experiments presented here, the answers to these two questions are: ‘yes’ and ‘very well’, respectively.
Large pterygium surgery: When coverage of the scleral bed justifies graft rotation.
Gargallo-Benedicto, A; Hernández Pérez, D; Olate-Pérez, Á; Betancur-Delgado, E; Cerdà-Ibáñez, M; Duch-Samper, A
2016-10-01
To perform a 12 month follow-up study to assess the safety and effectiveness of resection and conjunctival autograft fixed with Tissucol® in selected cases of large pterygium. The orientation of the graft was adapted to the morphology of the scleral bed for a better coverage free of traction, with limbal position being lost. A prospective, non-comparative study of 10 cases of grade II or superior pterygium (7 primary, 3 recurrent) with at least 8mm of limbal extension. A wide scleral bed was obtained after pterygium and Tenon resection, with larger grafts being required to cover the defects. A superior conjunctival autograft was harvested and fixed to bare sclera using Tissucol. The orientation was adapted to the morphology of the scleral bed and limbal position was lost. Patients were periodically assessed for recurrence and complications for a period of 12 months. Minor complications occurred in 4 eyes. In one case a buttonhole was formed during dissection of the graft. Two presented with small limbal dehiscence, but epithelialisation was completed in the first week. In a third case, it was necessary to increase topical corticosteroids for pyogenic granuloma on the donor site, with secondary increased intraocular pressure (IOP). There were no recurrences after 12 months follow-up. A conjunctival graft of appropriate size adapted to the morphology of the scleral bed to ensure good coverage free of tension, provides good surgical results in selected cases of pterygium, regardless of the conservation the limbal orientation, with no recurrences after one year follow-up. Copyright © 2016 Sociedad Española de Oftalmología. Published by Elsevier España, S.L.U. All rights reserved.
42 CFR 435.229 - Optional targeted low-income children.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 42 Public Health 4 2012-10-01 2012-10-01 false Optional targeted low-income children. 435.229... Coverage of Families and Children § 435.229 Optional targeted low-income children. The agency may provide Medicaid to— (a) All individuals under age 19 who are optional targeted low-income children as defined in...
42 CFR 435.229 - Optional targeted low-income children.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 42 Public Health 4 2010-10-01 2010-10-01 false Optional targeted low-income children. 435.229... Coverage of Families and Children § 435.229 Optional targeted low-income children. The agency may provide Medicaid to— (a) All individuals under age 19 who are optional targeted low-income children as defined in...
42 CFR 435.229 - Optional targeted low-income children.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 42 Public Health 4 2011-10-01 2011-10-01 false Optional targeted low-income children. 435.229... Coverage of Families and Children § 435.229 Optional targeted low-income children. The agency may provide Medicaid to— (a) All individuals under age 19 who are optional targeted low-income children as defined in...
The Utility and Versatility of Perforator-Based Propeller Flaps in Burn Care.
Teven, Chad M; Mhlaba, Julie; O'Connor, Annemarie; Gottlieb, Lawrence J
The majority of surgical burn care involves the use of skin grafts. However, there are cases when flaps are required or provide superior outcomes both in the acute setting and for postburn reconstruction. Rarely discussed in the context of burn care, the perforator-based propeller flap is an important option to consider. We describe our experience with perforator-based propeller flaps in the acute and reconstructive phases of burn care. We reviewed demographics, indications, operative details, and outcomes for patients whose burn care included the use of a perforator-based propeller flap at our institution from May 2007 to April 2015. Details of the surgical technique and individual cases are also discussed. Twenty-one perforator-based propeller flaps were used in the care of 17 burn patients. Six flaps (29%) were used in the acute phase for coverage of exposed joints, tendons, cartilage, and bone; coverage of open wounds; and preservation of range of motion (ROM) by minimizing scar contracture. Fifteen flaps (71%) were used for reconstruction of postburn deformities including coverage of chronic wounds, for coverage after scar contracture release, and to improve ROM. The majority of flaps (94% at follow-up) exhibited stable soft tissue coverage and good or improved ROM of adjacent joints. Three cases of partial flap loss and one case of total flap loss occurred. Perforator-based propeller flaps provide reliable vascularized soft tissue for coverage of vital structures and wounds, contracture release, and preservation of ROM across joints. Despite a relatively significant risk of minor complications particularly in the coverage of chronic wounds, our study supports their utility in both the acute and reconstructive phases of burn care.
Coverage-guaranteed sensor node deployment strategies for wireless sensor networks.
Fan, Gaojuan; Wang, Ruchuan; Huang, Haiping; Sun, Lijuan; Sha, Chao
2010-01-01
Deployment quality and cost are two conflicting aspects in wireless sensor networks. Random deployment, where the monitored field is covered by randomly and uniformly deployed sensor nodes, is an appropriate approach for large-scale network applications. However, their successful applications depend considerably on the deployment quality that uses the minimum number of sensors to achieve a desired coverage. Currently, the number of sensors required to meet the desired coverage is based on asymptotic analysis, which cannot meet deployment quality due to coverage overestimation in real applications. In this paper, we first investigate the coverage overestimation and address the challenge of designing coverage-guaranteed deployment strategies. To overcome this problem, we propose two deployment strategies, namely, the Expected-area Coverage Deployment (ECD) and BOundary Assistant Deployment (BOAD). The deployment quality of the two strategies is analyzed mathematically. Under the analysis, a lower bound on the number of deployed sensor nodes is given to satisfy the desired deployment quality. We justify the correctness of our analysis through rigorous proof, and validate the effectiveness of the two strategies through extensive simulation experiments. The simulation results show that both strategies alleviate the coverage overestimation significantly. In addition, we also evaluate two proposed strategies in the context of target detection application. The comparison results demonstrate that if the target appears at the boundary of monitored region in a given random deployment, the average intrusion distance of BOAD is considerably shorter than that of ECD with the same desired deployment quality. In contrast, ECD has better performance in terms of the average intrusion distance when the invasion of intruder is from the inside of monitored region.
Multi-Agent Cooperative Target Search
Hu, Jinwen; Xie, Lihua; Xu, Jun; Xu, Zhao
2014-01-01
This paper addresses a vision-based cooperative search for multiple mobile ground targets by a group of unmanned aerial vehicles (UAVs) with limited sensing and communication capabilities. The airborne camera on each UAV has a limited field of view and its target discriminability varies as a function of altitude. First, by dividing the whole surveillance region into cells, a probability map can be formed for each UAV indicating the probability of target existence within each cell. Then, we propose a distributed probability map updating model which includes the fusion of measurement information, information sharing among neighboring agents, information decay and transmission due to environmental changes such as the target movement. Furthermore, we formulate the target search problem as a multi-agent cooperative coverage control problem by optimizing the collective coverage area and the detection performance. The proposed map updating model and the cooperative control scheme are distributed, i.e., assuming that each agent only communicates with its neighbors within its communication range. Finally, the effectiveness of the proposed algorithms is illustrated by simulation. PMID:24865884
Minetti, Andrea; Hurtado, Northan; Grais, Rebecca F.; Ferrari, Matthew
2014-01-01
Current mass vaccination campaigns in measles outbreak response are nonselective with respect to the immune status of individuals. However, the heterogeneity in immunity, due to previous vaccination coverage or infection, may lead to potential bias of such campaigns toward those with previous high access to vaccination and may result in a lower-than-expected effective impact. During the 2010 measles outbreak in Malawi, only 3 of the 8 districts where vaccination occurred achieved a measureable effective campaign impact (i.e., a reduction in measles cases in the targeted age groups greater than that observed in nonvaccinated districts). Simulation models suggest that selective campaigns targeting hard-to-reach individuals are of greater benefit, particularly in highly vaccinated populations, even for low target coverage and with late implementation. However, the choice between targeted and nonselective campaigns should be context specific, achieving a reasonable balance of feasibility, cost, and expected impact. In addition, it is critical to develop operational strategies to identify and target hard-to-reach individuals. PMID:24131555
DOE Office of Scientific and Technical Information (OSTI.GOV)
KP, Karrthick; Kataria, T; Thiyagarajan, R
Purpose: To study the critical analysis and efficacy of Linac and Cyberknife (CK) treatment plans for acoustic neuroma/schwannoma. Methods: Twelve of acoustic neuroma/schwannoma patients were taken for these study that. Treatment plans were generated in Multiplan treatment planning system (TPS) for CK using 5,7.5 and 10mm diameter collimators. Target volumes were in the range of 0.280 cc to 9.256 cc. Prescription dose (Rx) ranges from 1150cGy to 1950cGy delivered over 1 to 3 Fractions. For same patients stereotactic Volumetric modulated arc plans were generated using Elekta Linac with MLC thickness of 4mm in Monaco TPS. Appropriate calculation algorithms and gridmore » size were used with same Rx and organ at risk (OAR) constrains for both Linac and CK plans. Treatment plans were developed to achieve at least 95% of the target volume to receive the Rx. The dosimetric indices such as conformity index (CI), coverage, OAR dose and volume receiving 50% of Rx (V50%) were used to evaluate the plans. Results: Target volumes ranges from 0.280 cc to 3.5cc shows the CI of 1.16±0.109 and 1.53±0.360 for cyberknife and Linac plans respectively. For small volume targets, the OARs were well spared in CK plans. There are no significant differences in CI and OAR doses were observed between CK and Linac plans that have the target volume >3.5 cc. Perhaps the V50% were lesser in CK plans, and found to be 12.8± 8.4 and 22.8 ± 15.0 for CK and Linac respectively. Conclusion: The analysis shows the importance of collimator size for small volume targets. The target volumes >3.5 cc can be treated in Linac as comparable with CK. For targets <3.5cc CK plans showed superior plan quality with better CI and OAR sparing than the Linac based plans. Further studies may require evaluating the clinical advantage of CK robotic system.« less
SU-F-T-419: Evaluation of PlanIQ Feasibility DVH as Planning Objectives for Skull Base SBRT Patients
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jiang, W; Wang, H; Chi, P
2016-06-15
Purpose: PlanIQ(Sun Nuclear Corporation) can provide feasibility measures on organs-at-risk(OARs) around the target based on depth, local anatomy density and energy of radiation beam used. This study is to test and evaluate PlanIQ feasibility DVHs as optimization objectives in the treatment planning process, and to investigate the potential to use them in routine clinical cases to improve planning efficiency. Methods: Two to three arcs VMAT Treatment plans were generated in Pinnacle based on PlanIQ feasibility DVH for six skull base patients who previously treated with SBRT. The PlanIQ feasibility DVH for each OAR consists of four zones – impossible (atmore » 100% target coverage), difficult, challenging and probable. Constrains to achieve DVH in difficult zone were used to start plan optimization. Further adjustment was made to improve coverage. The plan DVHs were compared to PlanIQ feasibility DVH to assess the dose received by 0%(D0), 5%(D5), 10%(D10) and 50%(D50) of the OAR volumes. Results: A total of 90 OARs were evaluated for 6 patients (mean 15 OARs, range 11–18 OARs). We used >98% PTV coverage as planning goal since it’s difficult to achieve 100% target coverage. For the generated plans, 96.7% of the OARs achieved D0 or D5 within difficult zone or impossible zone (ipsilateral OARs 93.5%, contralateral OARs 100%), while 90% and 65.6% of the OARs achieved D10 and D50 within difficult zone, respectively. Seventeen of the contralateral and out of field OARs achieved DVHs in impossible zone. For OARs adjacent or overlapped with target volume, the D0 and D5 are challenging to be optimized into difficult zone. All plans were completed within 2–4 adjustments to improve target coverage and uniformity. Conclusion: PlanIQ feasibility tool has the potential to provide difficult but achievable initial optimization objectives and therefore reduce the planning time to obtain a well optimized plan.« less
TU-AB-BRB-02: Stochastic Programming Methods for Handling Uncertainty and Motion in IMRT Planning
DOE Office of Scientific and Technical Information (OSTI.GOV)
Unkelbach, J.
The accepted clinical method to accommodate targeting uncertainties inherent in fractionated external beam radiation therapy is to utilize GTV-to-CTV and CTV-to-PTV margins during the planning process to design a PTV-conformal static dose distribution on the planning image set. Ideally, margins are selected to ensure a high (e.g. >95%) target coverage probability (CP) in spite of inherent inter- and intra-fractional positional variations, tissue motions, and initial contouring uncertainties. Robust optimization techniques, also known as probabilistic treatment planning techniques, explicitly incorporate the dosimetric consequences of targeting uncertainties by including CP evaluation into the planning optimization process along with coverage-based planning objectives. Themore » treatment planner no longer needs to use PTV and/or PRV margins; instead robust optimization utilizes probability distributions of the underlying uncertainties in conjunction with CP-evaluation for the underlying CTVs and OARs to design an optimal treated volume. This symposium will describe CP-evaluation methods as well as various robust planning techniques including use of probability-weighted dose distributions, probability-weighted objective functions, and coverage optimized planning. Methods to compute and display the effect of uncertainties on dose distributions will be presented. The use of robust planning to accommodate inter-fractional setup uncertainties, organ deformation, and contouring uncertainties will be examined as will its use to accommodate intra-fractional organ motion. Clinical examples will be used to inter-compare robust and margin-based planning, highlighting advantages of robust-plans in terms of target and normal tissue coverage. Robust-planning limitations as uncertainties approach zero and as the number of treatment fractions becomes small will be presented, as well as the factors limiting clinical implementation of robust planning. Learning Objectives: To understand robust-planning as a clinical alternative to using margin-based planning. To understand conceptual differences between uncertainty and predictable motion. To understand fundamental limitations of the PTV concept that probabilistic planning can overcome. To understand the major contributing factors to target and normal tissue coverage probability. To understand the similarities and differences of various robust planning techniques To understand the benefits and limitations of robust planning techniques.« less
Fundamental Vocabulary Selection Based on Word Familiarity
NASA Astrophysics Data System (ADS)
Sato, Hiroshi; Kasahara, Kaname; Kanasugi, Tomoko; Amano, Shigeaki
This paper proposes a new method for selecting fundamental vocabulary. We are presently constructing the Fundamental Vocabulary Knowledge-base of Japanese that contains integrated information on syntax, semantics and pragmatics, for the purposes of advanced natural language processing. This database mainly consists of a lexicon and a treebank: Lexeed (a Japanese Semantic Lexicon) and the Hinoki Treebank. Fundamental vocabulary selection is the first step in the construction of Lexeed. The vocabulary should include sufficient words to describe general concepts for self-expandability, and should not be prohibitively large to construct and maintain. There are two conventional methods for selecting fundamental vocabulary. The first is intuition-based selection by experts. This is the traditional method for making dictionaries. A weak point of this method is that the selection strongly depends on personal intuition. The second is corpus-based selection. This method is superior in objectivity to intuition-based selection, however, it is difficult to compile a sufficiently balanced corpora. We propose a psychologically-motivated selection method that adopts word familiarity as the selection criterion. Word familiarity is a rating that represents the familiarity of a word as a real number ranging from 1 (least familiar) to 7 (most familiar). We determined the word familiarity ratings statistically based on psychological experiments over 32 subjects. We selected about 30,000 words as the fundamental vocabulary, based on a minimum word familiarity threshold of 5. We also evaluated the vocabulary by comparing its word coverage with conventional intuition-based and corpus-based selection over dictionary definition sentences and novels, and demonstrated the superior coverage of our lexicon. Based on this, we conclude that the proposed method is superior to conventional methods for fundamental vocabulary selection.
Soh, Jun Hui; Lin, Yiyang; Rana, Subinoy; Ying, Jackie Y; Stevens, Molly M
2015-08-04
A versatile and sensitive colorimetric assay that allows the rapid detection of small-molecule targets using the naked eye is demonstrated. The working principle of the assay integrates aptamer-target recognition and the aptamer-controlled growth of gold nanoparticles (Au NPs). Aptamer-target interactions modulate the amount of aptamer strands adsorbed on the surface of aptamer-functionalized Au NPs via desorption of the aptamer strands when target molecules bind with the aptamer. Depending on the resulting aptamer coverage, Au NPs grow into morphologically varied nanostructures, which give rise to different colored solutions. Au NPs with low aptamer coverage grow into spherical NPs, which produce red-colored solutions, whereas Au NPs with high aptamer coverage grow into branched NPs, which produce blue-colored solutions. We achieved visible colorimetric response and nanomolar detection limits for the detection of ochratoxin A (1 nM) in red wine samples, as well as cocaine (1 nM) and 17β-estradiol (0.2 nM) in spiked synthetic urine and saliva, respectively. The detection limits were well within clinically and physiologically relevant ranges, and below the maximum food safety limits. The assay is highly sensitive, specific, and able to detect an array of analytes rapidly without requiring sophisticated equipment, making it relevant for many applications, such as high-throughput drug and clinical screening, food sampling, and diagnostics. Furthermore, the assay is easily adapted as a chip-based platform for rapid and portable target detection.
Role of step size and max dwell time in anatomy based inverse optimization for prostate implants
Manikandan, Arjunan; Sarkar, Biplab; Rajendran, Vivek Thirupathur; King, Paul R.; Sresty, N.V. Madhusudhana; Holla, Ragavendra; Kotur, Sachin; Nadendla, Sujatha
2013-01-01
In high dose rate (HDR) brachytherapy, the source dwell times and dwell positions are vital parameters in achieving a desirable implant dose distribution. Inverse treatment planning requires an optimal choice of these parameters to achieve the desired target coverage with the lowest achievable dose to the organs at risk (OAR). This study was designed to evaluate the optimum source step size and maximum source dwell time for prostate brachytherapy implants using an Ir-192 source. In total, one hundred inverse treatment plans were generated for the four patients included in this study. Twenty-five treatment plans were created for each patient by varying the step size and maximum source dwell time during anatomy-based, inverse-planned optimization. Other relevant treatment planning parameters were kept constant, including the dose constraints and source dwell positions. Each plan was evaluated for target coverage, urethral and rectal dose sparing, treatment time, relative target dose homogeneity, and nonuniformity ratio. The plans with 0.5 cm step size were seen to have clinically acceptable tumor coverage, minimal normal structure doses, and minimum treatment time as compared with the other step sizes. The target coverage for this step size is 87% of the prescription dose, while the urethral and maximum rectal doses were 107.3 and 68.7%, respectively. No appreciable difference in plan quality was observed with variation in maximum source dwell time. The step size plays a significant role in plan optimization for prostate implants. Our study supports use of a 0.5 cm step size for prostate implants. PMID:24049323
Environmental metabarcodes for insects: in silico PCR reveals potential for taxonomic bias.
Clarke, Laurence J; Soubrier, Julien; Weyrich, Laura S; Cooper, Alan
2014-11-01
Studies of insect assemblages are suited to the simultaneous DNA-based identification of multiple taxa known as metabarcoding. To obtain accurate estimates of diversity, metabarcoding markers ideally possess appropriate taxonomic coverage to avoid PCR-amplification bias, as well as sufficient sequence divergence to resolve species. We used in silico PCR to compare the taxonomic coverage and resolution of newly designed insect metabarcodes (targeting 16S) with that of existing markers [16S and cytochrome oxidase c subunit I (COI)] and then compared their efficiency in vitro. Existing metabarcoding primers amplified in silico <75% of insect species with complete mitochondrial genomes available, whereas new primers targeting 16S provided >90% coverage. Furthermore, metabarcodes targeting COI appeared to introduce taxonomic PCR-amplification bias, typically amplifying a greater percentage of Lepidoptera and Diptera species, while failing to amplify certain orders in silico. To test whether bias predicted in silico was observed in vitro, we created an artificial DNA blend containing equal amounts of DNA from 14 species, representing 11 insect orders and one arachnid. We PCR-amplified the blend using five primer sets, targeting either COI or 16S, with high-throughput amplicon sequencing yielding more than 6 million reads. In vitro results typically corresponded to in silico PCR predictions, with newly designed 16S primers detecting 11 insect taxa present, thus providing equivalent or better taxonomic coverage than COI metabarcodes. Our results demonstrate that in silico PCR is a useful tool for predicting taxonomic bias in mixed template PCR and that researchers should be wary of potential bias when selecting metabarcoding markers. © 2014 John Wiley & Sons Ltd.
Gauer, Tobias; Sothmann, Thilo; Blanck, Oliver; Petersen, Cordula; Werner, René
2018-06-01
Radiotherapy of extracranial metastases changed from normofractioned 3D CRT to extreme hypofractionated stereotactic treatment using VMAT beam techniques. Random interaction between tumour motion and dynamically changing beam parameters might result in underdosage of the CTV even for an appropriately dimensioned ITV (interplay effect). This study presents a clinical scenario of extreme hypofractionated stereotactic treatment and analyses the impact of interplay effects on CTV dose coverage. For a thoracic/abdominal phantom with an integrated high-resolution detector array placed on a 4D motion platform, dual-arc treatment plans with homogenous target coverage were created using a common VMAT technique and delivered in a single fraction. CTV underdosage through interplay effects was investigated by comparing dose measurements with and without tumour motion during plan delivery. Our study agrees with previous works that pointed out insignificant interplay effects on target coverage for very regular tumour motion patterns like simple sinusoidal motion. However, we identified and illustrated scenarios that are likely to result in a clinically relevant CTV underdosage. For tumour motion with abnormal variability, target coverage quantified by the CTV area receiving more than 98% of the prescribed dose decreased to 78% compared to 100% at static dose measurement. This study is further proof of considerable influence of interplay effects on VMAT dose delivery in stereotactic radiotherapy. For selected conditions of an exemplary scenario, interplay effects and related motion-induced target underdosage primarily occurred in tumour motion pattern with increased motion variability and VMAT plan delivery using complex MLC dose modulation.
Abdullah, Asnawi; Hort, Krishna; Abidin, Azwar Zaenal; Amin, Fadilah M
2012-01-01
Despite significant investment in improving service infrastructure and training of staff, public primary healthcare services in low-income and middle-income countries tend to perform poorly in reaching coverage targets. One of the factors identified in Aceh, Indonesia was the lack of operational funds for service provision. The objective of this study was to develop a simple and transparent costing tool that enables health planners to calculate the unit costs of providing basic health services to estimate additional budgets required to deliver services in accordance with national targets. The tool was developed using a standard economic approach that linked the input activities to achieving six national priority programs at primary healthcare level: health promotion, sanitation and environment health, maternal and child health and family planning, nutrition, immunization and communicable diseases control, and treatment of common illness. Costing was focused on costs of delivery of the programs that need to be funded by local government budgets. The costing tool consisting of 16 linked Microsoft Excel worksheets was developed and tested in several districts enabled the calculation of the unit costs of delivering of the six national priority programs per coverage target of each program (such as unit costs of delivering of maternal and child health program per pregnant mother). This costing tool can be used by health planners to estimate additional money required to achieve a certain level of coverage of programs, and it can be adjusted for different costs and program delivery parameters in different settings. Copyright © 2012 John Wiley & Sons, Ltd.
Evaluation of the measles, mumps and rubella vaccination catch-up campaign in England in 2013.
Simone, Benedetto; Balasegaram, Sooria; Gobin, Maya; Anderson, Charlotte; Charlett, André; Coole, Louise; Maguire, Helen; Nichols, Tom; Rawlings, Chas; Ramsay, Mary; Oliver, Isabel
2014-08-06
In January-March 2013 in England, confirmed measles cases increased in children aged 10-16 years. In April-September 2013, the National Health System and Public Health England launched a national measles-mumps-rubella (MMR) campaign based on data from Child Health Information Systems (CHIS) estimating that approximately 8% in this age group were unvaccinated. We estimated coverage at baseline, and, of those unvaccinated (target), the proportion vaccinated up to 20/08/2013 (mid-point) to inform further public health action. We selected a sample of 6644 children aged 10-16 years using multistage sampling from those reported unvaccinated in CHIS at baseline and validated their records against GP records. We adjusted the CHIS MMR vaccine coverage estimates correcting by the proportion of vaccinated children obtained through sample validation. We validated 5179/6644 (78%) of the sample records. Coverage at baseline was estimated as 94.7% (95% confidence intervals, CI: 93.5-96.0%), lower in London (86.9%, 95%CI: 83.0-90.9%) than outside (96.1%, 95%CI 95.5-96.8%). The campaign reached 10.8% (95%CI: 7.0-14.6%) of the target population, lower in London (7.1%, 95%CI: 4.9-9.3) than in the rest of England (11.4%, 95%CI: 7.0-15.9%). Coverage increased by 0.5% up to 95.3% (95% CI: 94.1-96.4%) but an estimated 210,000 10-16 year old children remained unvaccinated nationally. Baseline MMR coverage was higher than previously reported and was estimated to have reached the 95% campaign objective at midpoint. Eleven per cent of the target population were vaccinated during the campaign, and may be underestimated, especially in London. No further national campaigns are needed but targeted local vaccination activities should be considered. Copyright © 2014 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Syh, J; Syh, J; Patel, B
Purpose: This case study was designated to confirm the optimized plan was used to treat skin surface of left leg in three stages. 1. To evaluate dose distribution and plan quality by alternating of the source loading catheters pattern in flexible Freiberg Flap skin surface (FFSS) applicator. 2. To investigate any impact on Dose Volume Histogram (DVH) of large superficial surface target volume coverage. 3. To compare the dose distribution if it was treated with electron beam. Methods: The Freiburg Flap is a flexible mesh style surface mold for skin radiation or intraoperative surface treatments. The Freiburg Flap consists ofmore » multiple spheres that are attached to each other, holding and guiding up to 18 treatment catheters. The Freiburg Flap also ensures a constant distance of 5mm from the treatment catheter to the surface. Three treatment trials with individual planning optimization were employed: 18 channels, 9 channels of FF and 6 MeV electron beam. The comparisons were highlighted in target coverage, dose conformity and dose sparing of surrounding tissues. Results: The first 18 channels brachytherapy plan was generated with 18 catheters inside the skin-wrapped up flap (Figure 1A). A second 9 catheters plan was generated associated with the same calculation points which were assigned to match prescription for target coverage as 18 catheters plan (Figure 1B). The optimized inverse plan was employed to reduce the dose to adjacent structures such as tibia or fibula. The comparison of DVH’s was depicted on Figure 2. External beam of electron RT plan was depicted in Figure 3. Overcall comparisons among these three were illustrated in Conclusion: The 9-channel Freiburg flap flexible skin applicator offers a reasonably acceptable plan without compromising the coverage. Electron beam was discouraged to use to treat curved skin surface because of low target coverage and high dose in adjacent tissues.« less
Gao, Shuqin; Pan, Xu; Cui, Qingguo; Hu, Yukun; Ye, Xuehua; Dong, Ming
2014-01-01
Plant interactions greatly affect plant community structure. Dryland ecosystems are characterized by low amounts of unpredictable precipitation as well as by often having biological soil crusts (BSCs) on the soil surface. In dryland plant communities, plants interact mostly as they compete for water resources, and the direction and intensity of plant interaction varies as a function of the temporal fluctuation in water availability. Since BSCs influence water redistribution to some extent, a greenhouse experiment was conducted to test the hypothesis that the intensity and direction of plant interactions in a dryland plant community can be modified by BSCs. In the experiment, 14 combinations of four plant species (Artemisia ordosica, Artemisia sphaerocephala, Chloris virgata and Setaria viridis) were subjected to three levels of coverage of BSCs and three levels of water supply. The results show that: 1) BSCs affected plant interaction intensity for the four plant species: a 100% coverage of BSCs significantly reduced the intensity of competition between neighboring plants, while it was highest with a 50% coverage of BSCs in combination with the target species of A. sphaerocephala and C. virgata; 2) effects of the coverage of BSCs on plant interactions were modified by water regime when the target species were C. virgata and S. viridis; 3) plant interactions were species-specific. In conclusion, the percent coverage of BSCs affected plant interactions, and the effects were species-specific and could be modified by water regimes. Further studies should focus on effects of the coverage of BSCs on plant-soil hydrological processes. PMID:24498173
Gao, Shuqin; Pan, Xu; Cui, Qingguo; Hu, Yukun; Ye, Xuehua; Dong, Ming
2014-01-01
Plant interactions greatly affect plant community structure. Dryland ecosystems are characterized by low amounts of unpredictable precipitation as well as by often having biological soil crusts (BSCs) on the soil surface. In dryland plant communities, plants interact mostly as they compete for water resources, and the direction and intensity of plant interaction varies as a function of the temporal fluctuation in water availability. Since BSCs influence water redistribution to some extent, a greenhouse experiment was conducted to test the hypothesis that the intensity and direction of plant interactions in a dryland plant community can be modified by BSCs. In the experiment, 14 combinations of four plant species (Artemisia ordosica, Artemisia sphaerocephala, Chloris virgata and Setaria viridis) were subjected to three levels of coverage of BSCs and three levels of water supply. The results show that: 1) BSCs affected plant interaction intensity for the four plant species: a 100% coverage of BSCs significantly reduced the intensity of competition between neighboring plants, while it was highest with a 50% coverage of BSCs in combination with the target species of A. sphaerocephala and C. virgata; 2) effects of the coverage of BSCs on plant interactions were modified by water regime when the target species were C. virgata and S. viridis; 3) plant interactions were species-specific. In conclusion, the percent coverage of BSCs affected plant interactions, and the effects were species-specific and could be modified by water regimes. Further studies should focus on effects of the coverage of BSCs on plant-soil hydrological processes.
Maina, Isabella; Wanjala, Pepela; Soti, David; Kipruto, Hillary; Droti, Benson; Boerma, Ties
2017-10-01
To develop a systematic approach to obtain the best possible national and subnational statistics for maternal and child health coverage indicators from routine health-facility data. Our approach aimed to obtain improved numerators and denominators for calculating coverage at the subnational level from health-facility data. This involved assessing data quality and determining adjustment factors for incomplete reporting by facilities, then estimating local target populations based on interventions with near-universal coverage (first antenatal visit and first dose of pentavalent vaccine). We applied the method to Kenya at the county level, where routine electronic reporting by facilities is in place via the district health information software system. Reporting completeness for facility data were well above 80% in all 47 counties and the consistency of data over time was good. Coverage of the first dose of pentavalent vaccine, adjusted for facility reporting completeness, was used to obtain estimates of the county target populations for maternal and child health indicators. The country and national statistics for the four-year period 2012/13 to 2015/16 showed good consistency with results of the 2014 Kenya demographic and health survey. Our results indicated a stagnation of immunization coverage in almost all counties, a rapid increase of facility-based deliveries and caesarean sections and limited progress in antenatal care coverage. While surveys will continue to be necessary to provide population-based data, web-based information systems for health facility reporting provide an opportunity for more frequent, local monitoring of progress, in maternal and child health.
A Target Coverage Scheduling Scheme Based on Genetic Algorithms in Directional Sensor Networks
Gil, Joon-Min; Han, Youn-Hee
2011-01-01
As a promising tool for monitoring the physical world, directional sensor networks (DSNs) consisting of a large number of directional sensors are attracting increasing attention. As directional sensors in DSNs have limited battery power and restricted angles of sensing range, maximizing the network lifetime while monitoring all the targets in a given area remains a challenge. A major technique to conserve the energy of directional sensors is to use a node wake-up scheduling protocol by which some sensors remain active to provide sensing services, while the others are inactive to conserve their energy. In this paper, we first address a Maximum Set Covers for DSNs (MSCD) problem, which is known to be NP-complete, and present a greedy algorithm-based target coverage scheduling scheme that can solve this problem by heuristics. This scheme is used as a baseline for comparison. We then propose a target coverage scheduling scheme based on a genetic algorithm that can find the optimal cover sets to extend the network lifetime while monitoring all targets by the evolutionary global search technique. To verify and evaluate these schemes, we conducted simulations and showed that the schemes can contribute to extending the network lifetime. Simulation results indicated that the genetic algorithm-based scheduling scheme had better performance than the greedy algorithm-based scheme in terms of maximizing network lifetime. PMID:22319387
CCTV Coverage Index Based on Surveillance Resolution and Its Evaluation Using 3D Spatial Analysis
Choi, Kyoungah; Lee, Impyeong
2015-01-01
We propose a novel approach to evaluating how effectively a closed circuit television (CCTV) system can monitor a targeted area. With 3D models of the target area and the camera parameters of the CCTV system, the approach produces surveillance coverage index, which is newly defined in this study as a quantitative measure for surveillance performance. This index indicates the proportion of the space being monitored with a sufficient resolution to the entire space of the target area. It is determined by computing surveillance resolution at every position and orientation, which indicates how closely a specific object can be monitored with a CCTV system. We present full mathematical derivation for the resolution, which depends on the location and orientation of the object as well as the geometric model of a camera. With the proposed approach, we quantitatively evaluated the surveillance coverage of a CCTV system in an underground parking area. Our evaluation process provided various quantitative-analysis results, compelling us to examine the design of the CCTV system prior to its installation and understand the surveillance capability of an existing CCTV system. PMID:26389909
Bullets versus burgers: is it threat or relevance that captures attention?
de Oca, Beatrice M; Black, Alison A
2013-01-01
Previous studies have found that potentially dangerous stimuli are better at capturing attention than neutral stimuli, a finding sometimes called the threat superiority effect. However, non-threatening stimuli also capture attention in many studies of visual attention. In Experiment 1, the relevance superiority effect was tested with a visual search task comparing detection times for threatening stimuli (guns), pleasant but motivationally relevant stimuli (food), and neutral stimuli (flowers and chairs). Gun targets were detected more rapidly than both types of neutral targets, whereas food targets were detected more quickly than the neutral chair targets only. Guns were detected more rapidly than food. In Experiment 2, threatening targets (guns and snakes), pleasant but motivationally relevant targets (money and food), and neutral targets (trees and couches) were all presented with the same neutral distractors (cactus and pots) in order to control for the valence of the distractor stimulus across the three categories of target stimuli. Threatening and pleasant target categories facilitated attention relative to neutral targets. The results support the view that both threatening and pleasant pictures can be detected more rapidly than neutral targets.
A unique role of endogenous visual-spatial attention in rapid processing of multiple targets
Guzman, Emmanuel; Grabowecky, Marcia; Palafox, German; Suzuki, Satoru
2012-01-01
Visual spatial attention can be exogenously captured by a salient stimulus or can be endogenously allocated by voluntary effort. Whether these two attention modes serve distinctive functions is debated, but for processing of single targets the literature suggests superiority of exogenous attention (it is faster acting and serves more functions). We report that endogenous attention uniquely contributes to processing of multiple targets. For speeded visual discrimination, response times are faster for multiple redundant targets than for single targets due to probability summation and/or signal integration. This redundancy gain was unaffected when attention was exogenously diverted from the targets, but was completely eliminated when attention was endogenously diverted. This was not due to weaker manipulation of exogenous attention because our exogenous and endogenous cues similarly affected overall response times. Thus, whereas exogenous attention is superior for processing single targets, endogenous attention plays a unique role in allocating resources crucial for rapid concurrent processing of multiple targets. PMID:21517209
2007-02-01
bladder and the rectum are overprotected while the PTV coverage is undesirably reduced. On the other hand, if their maximum dose is increased and/or...B, the bladder and rectum were overprotected with undesirably low PTV coverage (84.54%). The reduction of their weighting factor increased PTV
Vila, Andrew; Tallman, Keri A.; Jacobs, Aaron T.; Liebler, Daniel C.; Porter, Ned A.; Marnett, Lawrence J.
2009-01-01
Polyunsaturated fatty acids (PUFA) are primary targets of free radical damage during oxidative stress. Diffusible electrophilic α, β-unsaturated aldehydes, such as 4-hydroxynonenal (HNE), have been shown to modify proteins that mediate cell signaling (e.g. IKK and Keap1) and alter gene expression pathways responsible for inducing antioxidant genes, heat shock proteins, and the DNA damage response. To fully understand cellular responses to HNE, it is important to determine its protein targets in an unbiased fashion. This requires a strategy for detecting and isolating HNE-modified proteins regardless of the nature of the chemical linkage between HNE and its targets. Azido or alkynyl derivatives of HNE were synthesized and demonstrated to be equivalent to HNE in their ability to induce heme oxygenase induction and induce apoptosis in colon cancer (RKO) cells. Cells exposed to the tagged HNE derivatives were lysed and exposed to reagents to effect Staudinger ligation or copper-catalyzed Huisgen 1,3 dipolar cycloaddition reaction (click chemistry) to conjugate HNE-adducted proteins with biotin for subsequent affinity purification. Both strategies yielded efficient biotinylation of tagged HNE-protein conjugates but click chemistry was found to be superior for recovery of biotinylated proteins from streptavidin-coated beads. Biotinylated proteins were detected in lysates from RKO cell incubations with azido-HNE at concentrations as low as 1 μM. These proteins were affinity purified with streptavidin beads and proteomic analysis was performed by linear ion trap mass spectrometry. Proteomic analysis revealed a dose-dependent increase in labeled proteins with increased sequence coverage at higher concentrations. Several proteins involved in stress signaling (heat shock proteins 70 and 90, and the 78-kDa glucose-regulated protein) were selectively adducted by azido- and alkynyl-HNE. The use of azido and alkynyl derivatives in conjunction with click chemistry appears to be a valuable approach for the identification of the protein targets of HNE. PMID:18232660
Ferrinho, Paulo; Dramé, Mohamed; Biai, Sidu; Lopes, Orlando; Sousa, Fernando de; Van Lerberghe, Wim
2013-01-01
Although many countries have improved vaccination coverage in recent years, some, including Guinea-Bissau, failed to meet expected targets. This paper tries to understand the main barriers to better vaccination coverage in the context of the GAVI-Alliance (The Global Alliance for Vaccines and Immunisation) cash-based support provided to Guinea-Bissau. The analysis is based on a document analysis and a three round Delphi study with a final consensus meeting. Consensus attributed about 25% of the failure to perform better to implementation problems; and about 10% to governance and also 10% to scarce resources. The qualitative analysis validates the importance of implementation issues and upgraded the relevance of the human resources crisis as an important drawback. The recommendations were balanced in their upstream-downstream focus but were blind to health information issues and logistical difficulties. It is commendable that such a fragile state, with all sorts of barriers, manages to sustain a slow steady growth of its vaccination coverage. Not reaching the targets set reflects the inappropriateness of those targets rather than a lack of commitment of the health workforce. In the unstable context of countries such as Guinea-Bissau, the predictability of the funds from global health initiatives like the GAVI-Alliance seem to make all the difference in achieving small consistent health gains even in the presence of other major bottlenecks.
Fu, Yuchuan; Deng, Min; Zhou, Xiaojuan; Lin, Qiang; Du, Bin; Tian, Xue; Xu, Yong; Wang, Jin; Lu, You; Gong, Youling
2017-01-01
To evaluate the lung sparing in intensity-modulated radiation therapy (IMRT) for patients with upper thoracic esophageal tumors extending inferiorly to the thorax by different beam arrangement. Overall, 15 patient cases with cancer of upper thoracic esophagus were selected for a retrospective treatment-planning study. Intensity-modulated radiation therapy plans using 4, 5, and 7 beams (4B, 5B, and 7B) were developed for each patient by direct machine parameter optimization (DMPO). All plans were evaluated with respect to dose volumes to irradiated targets and normal structures, with statistical comparisons made between 4B with 5B and 7B intensity-modulated radiation therapy plans. Differences among plans were evaluated using a two-tailed Friedman test at a statistical significance of p < 0.05. The maximum dose, average dose, and the conformity index (CI) of planning target volume 1 (PTV1) were similar for 3 plans for each case. No significant difference of coverage for planning target volume 1 and maximum dose for spinal cords were observed among 3 plans in present study (p > 0.05). The average V 5 , V 13 , V 20 , mean lung dose, and generalized equivalent uniform dose (gEUD) for the total lung were significantly lower in 4B-plans than those data in 5B-plans and 7B-plans (p < 0.01). Although the average V 30 for the total lung were significantly higher in 4B-plans than those in 5B-plans and 7B-plans (p < 0.05). In addition, when comparing with the 4B-plans, the conformity/heterogeneity index of the 5B- and 7B-plans were significantly superior (p < 0.05). The 4B-intensity-modulated radiation therapy plan has advantage to address the specialized problem of lung sparing to low- and intermediate-dose exposure in the thorax when dealing with relative long tumors extended inferiorly to the thoracic esophagus for upper esophageal carcinoma with the cost for less conformity. Studies are needed to compare the superiority of volumetric modulated arc therapy with intensity-modulated radiation therapy technique. Copyright © 2017 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.
Kundrick, Avery; Huang, Zhuojie; Carran, Spencer; Kagoli, Matthew; Grais, Rebecca Freeman; Hurtado, Northan; Ferrari, Matthew
2018-06-15
Despite progress towards increasing global vaccination coverage, measles continues to be one of the leading, preventable causes of death among children worldwide. Whether and how to target sub-national areas for vaccination campaigns continues to remain a question. We analyzed three metrics for prioritizing target areas: vaccination coverage, susceptible birth cohort, and the effective reproductive ratio (R E ) in the context of the 2010 measles epidemic in Malawi. Using case-based surveillance data from the 2010 measles outbreak in Malawi, we estimated vaccination coverage from the proportion of cases reporting with a history of prior vaccination at the district and health facility catchment scale. Health facility catchments were defined as the set of locations closer to a given health facility than to any other. We combined these estimates with regional birth rates to estimate the size of the annual susceptible birth cohort. We also estimated the effective reproductive ratio, R E , at the health facility polygon scale based on the observed rate of exponential increase of the epidemic. We combined these estimates to identify spatial regions that would be of high priority for supplemental vaccination activities. The estimated vaccination coverage across all districts was 84%, but ranged from 61 to 99%. We found that 8 districts and 354 health facility catchments had estimated vaccination coverage below 80%. Areas that had highest birth cohort size were frequently large urban centers that had high vaccination coverage. The estimated R E ranged between 1 and 2.56. The ranking of districts and health facility catchments as priority areas varied depending on the measure used. Each metric for prioritization may result in discrete target areas for vaccination campaigns; thus, there are tradeoffs to choosing one metric over another. However, in some cases, certain areas may be prioritized by all three metrics. These areas should be treated with particular concern. Furthermore, the spatial scale at which each metric is calculated impacts the resulting prioritization and should also be considered when prioritizing areas for vaccination campaigns. These methods may be used to allocate effort for prophylactic campaigns or to prioritize response for outbreak response vaccination.
Temporal bone radiography using the orthopantomograph
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tatezawa, T.
1981-09-01
Temporal bone radiographs obtained with an Orthopantomograph were compared with conventional radiographs. In acoustic neurinoma, cholesteatoma, otitis media, and middle fossa tumors, both methods demonstrated the abnormalities well. In two cases with lesions extending beyond the range of conventional projections, the broad orthopantomographic coverage was very valuable. Mastoid air cells, the mastoid process, petrous ridge, and internal auditory meatus were well demonstrated by both techniques. Orthopantomography was found to be superior in the demonstration of the petrous apex, while the superior semicircular canal was better demonstrated on the conventional views. Bilateral symmetry was particularly good and because of fewer films,more » radiation exposure was considerably less with orthopantomography. For many applications, orthopantomography is an adequate convenient substitute for conventional methods of examining the temporal bones.« less
NASA Technical Reports Server (NTRS)
Hall, F. G.; Huemmrich, K. F.; Strebel, D. E.; Goetz, S. J.; Nickeson, J. E.; Woods, K. D.
1992-01-01
Described here are the results of a NASA field experiment conducted in the Superior National Forest near Ely, Minnesota, during the summers of 1983 and 1984. The purpose of the experiment was to examine the use of remote sensing to provide measurements of biophysical parameters in the boreal forests. Leaf area index, biomass, net primary productivity, canopy coverage, overstory and understory species composition data are reported for about 60 sites, representing a range of stand density and age for aspen and spruce. Leaf, needle, and bark high-resolution spectral reflectance and transmittance data are reported for the major boreal forest species. Canopy bidirectional reflectance measurements are provided from a helicopter-mounted Barnes Multiband Modular Radiometer (MMR) and the Thematic Mapper Simulator (TMS) on the NASA C-130 aircraft.
42 CFR 435.4 - Definitions and use of terms.
Code of Federal Regulations, 2010 CFR
2010-10-01
... disabled individual; Optional targeted low-income child means a child under age 19 who meets the financial and categorical standards described below. (1) Financial need. An optional targeted low-income child... optional targeted low-income child is not covered under a group health plan or health insurance coverage...
Kanya, Lucy; Obare, Francis; Warren, Charlotte; Abuya, Timothy; Askew, Ian; Bellows, Ben
2014-07-01
There has been increased interest in and experimentation with demand-side mechanisms such as the use of vouchers that place purchasing power in the hands of targeted consumers to improve the uptake of healthcare services in low-income settings. A key measure of the success of such interventions is the extent to which the programmes have succeeded in reaching the target populations. This article estimates the coverage of facility deliveries by a maternal health voucher programme in South-western Uganda and examines whether such coverage is correlated with district-level characteristics such as poverty density and the number of contracted facilities. Analysis entails estimating the voucher coverage of health facility deliveries among the general population and poor population (PP) using programme data for 2010, which was the most complete calendar year of implementation of the Uganda safe motherhood (SM) voucher programme. The results show that: (1) the programme paid for 38% of estimated deliveries among the PP in the targeted districts, (2) there was a significant negative correlation between the poverty density in a district and proportions of births to poor women that were covered by the programme and (3) improving coverage of health facility deliveries for poor women is dependent upon increasing the sales and redemption rates. The findings suggest that to the extent that the programme stimulated demand for SM services by new users, it has the potential of increasing facility-based births among poor women in the region. In addition, the significant negative correlation between the poverty density and the proportions of facility-based births to poor women that are covered by the voucher programme suggests that there is need to increase both voucher sales and the rate of redemption to improve coverage in districts with high levels of poverty. Published by Oxford University Press in association with The London School of Hygiene and Tropical Medicine © The Author 2013; all rights reserved.
Arbyn, Marc; Fabri, Valérie; Temmerman, Marleen; Simoens, Cindy
2014-01-01
To assess the coverage for cervical cancer screening as well as the use of cervical cytology, colposcopy and other diagnostic and therapeutic interventions on the uterine cervix in Belgium, using individual health insurance data. The Intermutualistic Agency compiled a database containing 14 million records from reimbursement claims for Pap smears, colposcopies, cervical biopsies and surgery, performed between 2002 and 2006. Cervical cancer screening coverage was defined as the proportion of women aged 25-64 that had a Pap smear within the last 3 years. Cervical cancer screening coverage was 61% at national level, for the target population of women between 25 and 64 years old, in the period 2004-2006. Differences between the 3 regions were small, but varied more substantially between provinces. Coverage was 70% for 25-34 year old women, 67% for those aged 35-39 years, and decreased to 44% in the age group of 60-64 years. The median screening interval was 13 months. The screening coverage varied substantially by social category: 40% and 64%, in women categorised as beneficiary or not-beneficiary of increased reimbursement from social insurance, respectively. In the 3-year period 2004-2006, 3.2 million screen tests were done in the target group consisting of 2.8 million women. However, only 1.7 million women got one or more smears and 1.1 million women had no smears, corresponding to an average of 1.88 smears per woman in three years of time. Colposcopy was excessively used (number of Pap smears over colposcopies = 3.2). The proportion of women with a history of conisation or hysterectomy, before the age of 65, was 7% and 19%, respectively. The screening coverage increased slightly from 59% in 2000 to 61% in 2006. The screening intensity remained at a high level, and the number of cytological examinations was theoretically sufficient to cover more than the whole target population.
Progress Toward Measles Elimination - African Region, 2013-2016.
Masresha, Balcha G; Dixon, Meredith G; Kriss, Jennifer L; Katsande, Reggis; Shibeshi, Messeret E; Luce, Richard; Fall, Amadou; Dosseh, Annick R G A; Byabamazima, Charles R; Dabbagh, Alya J; Goodson, James L; Mihigo, Richard
2017-05-05
In 2011, the 46 World Health Organization (WHO) African Region (AFR) member states established a goal of measles elimination* by 2020, by achieving 1) ≥95% coverage of their target populations with the first dose of measles-containing vaccine (MCV1) at national and district levels; 2) ≥95% coverage with measles-containing vaccine (MCV) per district during supplemental immunization activities (SIAs); and 3) confirmed measles incidence of <1 case per 1 million population in all countries (1). Two key surveillance performance indicator targets include 1) investigating ≥2 cases of nonmeasles febrile rash illness per 100,000 population annually, and 2) obtaining a blood specimen from ≥1 suspected measles case in ≥80% of districts annually (2). This report updates the previous report (3) and describes progress toward measles elimination in AFR during 2013-2016. Estimated regional MCV1 coverage † increased from 71% in 2013 to 74% in 2015. § Seven (15%) countries achieved ≥95% MCV1 coverage in 2015. ¶ The number of countries providing a routine second MCV dose (MCV2) increased from 11 (24%) in 2013 to 23 (49%) in 2015. Forty-one (79%) of 52 SIAs** during 2013-2016 reported ≥95% coverage. Both surveillance targets were met in 19 (40%) countries in 2016. Confirmed measles incidence in AFR decreased from 76.3 per 1 million population to 27.9 during 2013-2016. To eliminate measles by 2020, AFR countries and partners need to 1) achieve ≥95% 2-dose MCV coverage through improved immunization services, including second dose (MCV2) introduction; 2) improve SIA quality by preparing 12-15 months in advance, and using readiness, intra-SIA, and post-SIA assessment tools; 3) fully implement elimination-standard surveillance †† ; 4) conduct annual district-level risk assessments; and 5) establish national committees and a regional commission for the verification of measles elimination.
Coverage Gains After the Affordable Care Act Among the Uninsured in Minnesota.
Call, Kathleen Thiede; Lukanen, Elizabeth; Spencer, Donna; Alarcón, Giovann; Kemmick Pintor, Jessie; Baines Simon, Alisha; Gildemeister, Stefan
2015-11-01
We determined whether and how Minnesotans who were uninsured in 2013 gained health insurance coverage in 2014, 1 year after the Affordable Care Act (ACA) expanded Medicaid coverage and enrollment. Insurance status and enrollment experiences came from the Minnesota Health Insurance Transitions Study (MH-HITS), a follow-up telephone survey of children and adults in Minnesota who had no health insurance in the fall of 2013. ACA had a tempered success in Minnesota. Outreach and enrollment efforts were effective; one half of those previously uninsured gained coverage, although many reported difficulty signing up (nearly 62%). Of the previously uninsured who gained coverage, 44% obtained their coverage through MNsure, Minnesota's insurance marketplace. Most of those who remained uninsured heard of MNsure and went to the Web site. Many still struggled with the enrollment process or reported being deterred by the cost of coverage. Targeting outreach, simplifying the enrollment process, focusing on affordability, and continuing funding for in-person assistance will be important in the future.
Coverage Gains After the Affordable Care Act Among the Uninsured in Minnesota
Lukanen, Elizabeth; Spencer, Donna; Alarcón, Giovann; Kemmick Pintor, Jessie; Baines Simon, Alisha; Gildemeister, Stefan
2015-01-01
Objectives. We determined whether and how Minnesotans who were uninsured in 2013 gained health insurance coverage in 2014, 1 year after the Affordable Care Act (ACA) expanded Medicaid coverage and enrollment. Methods. Insurance status and enrollment experiences came from the Minnesota Health Insurance Transitions Study (MH-HITS), a follow-up telephone survey of children and adults in Minnesota who had no health insurance in the fall of 2013. Results. ACA had a tempered success in Minnesota. Outreach and enrollment efforts were effective; one half of those previously uninsured gained coverage, although many reported difficulty signing up (nearly 62%). Of the previously uninsured who gained coverage, 44% obtained their coverage through MNsure, Minnesota’s insurance marketplace. Most of those who remained uninsured heard of MNsure and went to the Web site. Many still struggled with the enrollment process or reported being deterred by the cost of coverage. Conclusions. Targeting outreach, simplifying the enrollment process, focusing on affordability, and continuing funding for in-person assistance will be important in the future. PMID:26447912
DNA barcoding in the media: does coverage of cool science reflect its social context?
Geary, Janis; Camicioli, Emma; Bubela, Tania
2016-09-01
Paul Hebert and colleagues first described DNA barcoding in 2003, which led to international efforts to promote and coordinate its use. Since its inception, DNA barcoding has generated considerable media coverage. We analysed whether this coverage reflected both the scientific and social mandates of international barcoding organizations. We searched newspaper databases to identify 900 English-language articles from 2003 to 2013. Coverage of the science of DNA barcoding was highly positive but lacked context for key topics. Coverage omissions pose challenges for public understanding of the science and applications of DNA barcoding; these included coverage of governance structures and issues related to the sharing of genetic resources across national borders. Our analysis provided insight into how barcoding communication efforts have translated into media coverage; more targeted communication efforts may focus media attention on previously omitted, but important topics. Our analysis is timely as the DNA barcoding community works to establish the International Society for the Barcode of Life.
Radiation therapy for breast cancer: Literature review
DOE Office of Scientific and Technical Information (OSTI.GOV)
Balaji, Karunakaran, E-mail: karthik.balaji85@gmail.com; School of Advanced Sciences, VIT University, Vellore; Subramanian, Balaji
Concave shape with variable size target volume makes treatment planning for the breast/chest wall a challenge. Conventional techniques used for the breast/chest wall cancer treatment provided better sparing of organs at risk (OARs), with poor conformity and uniformity to the target volume. Advanced technologies such as intensity modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT) improve the target coverage at the cost of higher low dose volumes to OARs. Novel hybrid techniques present promising results in breast/chest wall irradiation in terms of target coverage as well as OARs sparing. Several published data compared these technologies for the benefit ofmore » the breast/chest wall with or without nodal volumes. The aim of this article is to review relevant data and identify the scope for further research in developing optimal treatment plan for breast/chest wall cancer treatment.« less
Ships and Maritime Targets Observation Campaigns Using Available C- and X-Band SAR Satellite
NASA Astrophysics Data System (ADS)
Velotto, Domenico; Bentes, Carlos; Lehner, Susanne
2015-04-01
Obviously, radar resolution and swath width are two very important factors when it comes to synthetic aperture radar (SAR) maritime targets detections. The dilemma of using single polarization SAR imagery with higher resolution and coverage or quad- (or dual- polarimetric) imagery with its richness of information, is still unsolved when it comes to this application.In the framework of ESA project MARISS and EU project DOLPHIN, in situ campaigns aimed at solving this dilemma have been carried out. Single and multi- polarimetric SAR data acquired by TerraSAR-X, RADARSAT-2 and COSMO-SkyMed have been acquired with close time gaps and partial coverage overlap. In this way several moving and non-moving maritime targets have been imaged with different polarization, geometry and working frequency. Available ground truth reports provided by Automatic Identification System (AIS) data, nautical chart and wind farm location are used to validate the different types of maritime targets.
Targeted Help for Spoken Dialogue Systems: Intelligent Feedback Improves Naive Users' Performance
NASA Technical Reports Server (NTRS)
Hockey, Beth Ann; Lemon, Oliver; Campana, Ellen; Hiatt, Laura; Aist, Gregory; Hieronymous, Jim; Gruenstein, Alexander; Dowding, John
2003-01-01
We present experimental evidence that providing naive users of a spoken dialogue system with immediate help messages related to their out-of-coverage utterances improves their success in using the system. A grammar-based recognizer and a Statistical Language Model (SLM) recognizer are run simultaneously. If the grammar-based recognizer suceeds, the less accurate SLM recognizer hypothesis is not used. When the grammar-based recognizer fails and the SLM recognizer produces a recognition hypothesis, this result is used by the Targeted Help agent to give the user feed-back on what was recognized, a diagnosis of what was problematic about the utterance, and a related in-coverage example. The in-coverage example is intended to encourage alignment between user inputs and the language model of the system. We report on controlled experiments on a spoken dialogue system for command and control of a simulated robotic helicopter.
Lin, Jing; Pramono, Zacharias Aloysius Dwi; Maurer-Stroh, Sebastian
2016-01-01
The multiple circulating human influenza A virus subtypes coupled with the perpetual genomic mutations and segment reassortment events challenge the development of effective therapeutics. The capacity to drug most RNAs motivates the investigation on viral RNA targets. 123,060 segment sequences from 35,938 strains of the most prevalent subtypes also infecting humans–H1N1, 2009 pandemic H1N1, H3N2, H5N1 and H7N9, were used to identify 1,183 conserved RNA target sequences (≥15-mer) in the internal segments. 100% theoretical coverage in simultaneous heterosubtypic targeting is achieved by pairing specific sequences from the same segment (“Duals”) or from two segments (“Doubles”); 1,662 Duals and 28,463 Doubles identified. By combining specific Duals and/or Doubles to form a target graph wherein an edge connecting two vertices (target sequences) represents a Dual or Double, it is possible to hedge against antiviral resistance besides maintaining 100% heterosubtypic coverage. To evaluate the hedging potential, we define the hedge-factor as the minimum number of resistant target sequences that will render the graph to become resistant i.e. eliminate all the edges therein; a target sequence or a graph is considered resistant when it cannot achieve 100% heterosubtypic coverage. In an n-vertices graph (n ≥ 3), the hedge-factor is maximal (= n– 1) when it is a complete graph i.e. every distinct pair in a graph is either a Dual or Double. Computational analyses uncover an extensive number of complete graphs of different sizes. Monte Carlo simulations show that the mutation counts and time elapsed for a target graph to become resistant increase with the hedge-factor. Incidentally, target sequences which were reported to reduce virus titre in experiments are included in our target graphs. The identity of target sequence pairs for heterosubtypic targeting and their combinations for hedging antiviral resistance are useful toolkits to construct target graphs for different therapeutic objectives. PMID:26771381
Superior Recess Access of the Lumbar Facet Joint.
Demir-Deviren, Sibel; Singh, Sukhminder; Hanelin, Joshua
2017-04-01
Descriptive approach to accessing the lumbar facet joint by superior recess. This study is aimed to describe an approach to accessing the lumbar facet joint through targeting the superior recess during lumbar facet joint injections. Lumbar facet joint injections are routinely performed for both the diagnosis and treatment of chronic low back pain. Previous studies either did not specify which part of the joint to target, or recommended targeting the inferior aspect of the joint to access the inferior recess. One study did mention the superior recess as an alternative to injecting the inferior recess, but none has focused on description of the technique. This is the first time this technique has been described. The records and fluoroscopic images were reviewed for all patients over a period of 9 months (January-September 2012) using the proposed technique. This resulted in a total of 48 patients; 15 men, 29 women, and a total of 117 facet joint intra-articular injections. Among these 48 patients, injections were repeated in total of 4 cases. The average time of injections among 4 repeat cases was 121 days. The success of the procedure was confirmed with an arthrogram demonstrating contrast flowing from the superior recess inferiorly through the joint space. Successful access of the lumbar facet joint through puncture of the superior recess was seen in 114 cases, with 3 unsuccessful attempts to enter facet joints due to osteophytes at involved levels. There were no complications observed during the procedure. We find this approach to be highly successful, safe, and well tolerated by the patient and recommend it as a technique for access of the lumbar facet joint in those patients in whom direct puncture of the inferior recess is difficult.
Nie, Qi-Yang; Maurer, Mara; Müller, Hermann J; Conci, Markus
2016-05-01
Illusory Kanizsa figures demonstrate that a perceptually completed whole is more than the sum of its composite parts. In the current study, we explored part/whole relationships in object completion using the configural superiority effect (CSE) with illusory figures (Pomerantz & Portillo, 2011). In particular, we investigated to which extent the CSE is modulated by closure in target and distractor configurations. Our results demonstrated a typical CSE, with detection of a configural whole being more efficient than the detection of a corresponding part-level target. Moreover, the CSE was more pronounced when grouped objects were presented in distractors rather than in the target. A follow-up experiment systematically manipulated closure in whole target or, respectively, distractor configurations. The results revealed the effect of closure to be again stronger in distractor, rather than in target configurations, suggesting that closure primarily affects the inhibition of distractors, and to a lesser extent the selection of the target. In addition, a drift-diffusion model analysis of our data revealed that efficient distractor inhibition expedites the rate of evidence accumulation, with closure in distractors particularly speeding the drift toward the decision boundary. In sum, our findings demonstrate that the CSE in Kanizsa figures derives primarily from the inhibition of closed distractor objects, rather than being driven by a conspicuous target configuration. Altogether, these results support a fundamental role of inhibition in driving configural superiority effects in visual search. Copyright © 2016 Elsevier B.V. All rights reserved.
Cho, Jungwoo; You, Myoungsoon; Yoon, Yoonjin
2017-01-01
In highly urbanized area where traffic condition fluctuates constantly, transportation infrastructure is one of the major contributing factors to Emergency Medical Service (EMS) availability and patient outcome. In this paper, we assess the impact of traffic fluctuation to the EMS first response availability in urban area, by evaluating the k-minute coverage under 21 traffic scenarios. The set of traffic scenarios represents the time-of-day and day-of-week effects, and is generated by combining road link speed information from multiple historical speed databases. In addition to the k-minute area coverage calculation, the k-minute population coverage is also evaluated for every 100m by 100m grid that partitions the case study area of Seoul, South Korea. In the baseline case of traveling at the speed limit, both the area and population coverage reached nearly 100% when compared to the five-minute travel time national target. Employing the proposed LoST (Loss of Serviceability due to Traffic) index, which measures coverage reduction in percentage compared to the baseline case, we find that the citywide average LoST for area and population coverage are similar at 34.2% and 33.8%. However, district-wise analysis reveals that such reduction varies significantly by district, and the magnitude of area and population coverage reduction is not always proportional. We conclude that the effect of traffic variation is significant to successful urban EMS first response performance, and regional variation is evident among local districts. Complexity in the urban environment requires a more adaptive approach in public health resource management and EMS performance target determination.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nie, K; Yue, N; Chen, T
2014-06-15
Purpose: In lung radiation treatment, PTV is formed with a margin around GTV (or CTV/ITV). Although GTV is most likely of water equivalent density, the PTV margin may be formed with the surrounding low-density tissues, which may lead to unreal dosimetric plan. This study is to evaluate whether the concern of dose calculation inside the PTV with only low density margin could be justified in lung treatment. Methods: Three SBRT cases were analyzed. The PTV from the original plan (Plan-O) was created with a 5–10 mm margin outside the ITV to incorporate setup errors and all mobility from 10 respiratorymore » phases. Test plans were generated with the GTV shifted to the PTV edge to simulate the extreme situations with maximum setup uncertainties. Two representative positions as the very posterior-superior (Plan-PS) and anterior-inferior (Plan-AI) edge were considered. The virtual GTV was assigned a density of 1.0 g.cm−3 and surrounding lung, including the PTV margin, was defined as 0.25 g.cm−3. Also, additional plan with a 1mm tissue-margin instead of full lung-margin was created to evaluate whether a composite-margin (Plan-Comp) has a better approximation for dose calculation. All plans were generated on the average CT using Analytical Anisotropic Algorithm with heterogeneity correction on and all planning parameters/monitor unites remained unchanged. DVH analyses were performed for comparisons. Results: Despite the non-static dose distribution, the high-dose region synchronized with tumor positions. This might due to scatter conditions as greater doses were absorbed in the solid-tumor than in the surrounding low-density lungtissue. However, it still showed missing target coverage in general. Certain level of composite-margin might give better approximation for the dosecalculation. Conclusion: Our exploratory results suggest that with the lungmargin only, the planning dose of PTV might overestimate the coverage of the target during treatment. The significance of this overestimation might warrant further investigation.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Montero, A Barragan; Differding, S; Lee, J
Purpose: The work aims to 1) prove the feasibility of dose painting by numbers (DPBN) in proton therapy with usual contour-driven plan optimization and 2) compare the achieved plan quality to that of rotational IMRT. Methods: For two patients with head and neck cancers, voxel-by-voxel prescription to the target volume (PTV-PET) was calculated from {sup 18} FDG-PET images and converted to contour-based prescription by defining several sub-contours. Treatments were planned with RayStation (RaySearch Laboratories, Sweden) and proton pencil beam scanning modality. In order to determine the optimal plan parameters to approach the DPBN prescription, the effect of the number ofmore » fields, number of sub-contours and use of range shifter were tested separately on each patient. The number of sub-contours were increased from 3 to 11 while the number of fields were set to 3, 5, 7 and 9. Treatment plans were also optimized on two rotational IMRT systems (TomoTherapy and Varian RapidArc) using previously published guidelines. Results: For both patients, more than 99% of the PTV-PET received at least 95% of the prescribed dose while less than 1% of the PTV-PET received more than 105%, which demonstrates the feasibility of the treatment. Neither the use of a range shifter nor the increase of the number of fields had a significant influence on PTV coverage. Plan quality increased when increasing number of fields up to 7 or 9 and slightly decreased for a bigger number of sub-contours. Good OAR sparing is achieved while keeping high plan quality. Finally, proton therapy achieved significantly better plan quality than rotational IMRT. Conclusion: Voxel-by-voxel prescriptions can be approximated accurately in proton therapy using a contour-driven optimization. Target coverage is nearly insensitive to the number of fields and the use of a range shifter. Finally, plan quality assessment confirmed the superiority of proton therapy compared to rotational IMRT.« less
Chapman, Audrey R
2016-12-15
The UN's Sustainable Development Goals (SDGs), adopted in September 2015, include a comprehensive health goal, "to ensure healthy lives and promote well-being at all ages." The health goal (SDG 3) has nine substantive targets and four additional targets which are identified as a means of implementation. One of these commitments, to achieve universal health coverage (UHC), has been acknowledged as central to the achievement of all of the other health targets. As defined in the SDGs, UHC includes financial risk protection, access to quality essential health-care services, and access to safe, effective, quality and affordable essential medicines and vaccines for all. This article evaluates the extent to which the UHC target in the SDGs conforms with the requirements of the right to health enumerated in the International Covenant on Economic, Social and Cultural Rights, the Convention on the Rights of the Child, and other international human rights instruments and interpreted by international human rights bodies. It does so as a means to identify strengths and weaknesses in the framing of the UHC target that are likely to affect its implementation. While UHC as defined in the SDGs overlaps with human rights standards, there are important human rights omissions that will likely weaken the implementation and reduce the potential benefits of the UHC target. The most important of these is the failure to confer priority to providing access to health services to poor and disadvantaged communities in the process of expanding health coverage and in determining which health services to provide. Unless the furthest behind are given priority and strategies adopted to secure their participation in the development of national health plans, the SDGs, like the MDGs, are likely to leave the most disadvantaged and vulnerable communities behind.
Alberti, K P; Guthmann, J P; Fermon, F; Nargaye, K D; Grais, R F
2008-03-01
Inadequate evaluation of vaccine coverage after mass vaccination campaigns, such as used in national measles control programmes, can lead to inappropriate public health responses. Overestimation of vaccination coverage may leave populations at risk, whilst underestimation can lead to unnecessary catch-up campaigns. The problem is more complex in large urban areas where vaccination coverage may be heterogeneous and the programme may have to be fine-tuned at the level of geographic subunits. Lack of accurate population figures in many contexts further complicates accurate vaccination coverage estimates. During the evaluation of a mass vaccination campaign carried out in N'Djamena, the capital of Chad, Lot Quality Assurance Sampling was used to estimate vaccination coverage. Using this method, vaccination coverage could be evaluated within smaller geographic areas of the city as well as for the entire city. Despite the lack of accurate population data by neighbourhood, the results of the survey showed heterogeneity of vaccination coverage within the city. These differences would not have been identified using a more traditional method. The results can be used to target areas of low vaccination coverage during follow-up vaccination activities.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lens, Eelco, E-mail: e.lens@amc.uva.nl; Horst, Astrid van der; Versteijne, Eva
2015-07-01
Purpose: The midventilation (midV) approach can be used to take respiratory-induced pancreatic tumor motion into account during radiation therapy. In this study, the dosimetric consequences for organs at risk and tumor coverage of using a midV approach compared with using an internal target volume (ITV) were investigated. Methods and Materials: For each of the 18 patients, 2 treatment plans (25 × 2.0 Gy) were created, 1 using an ITV and 1 using a midV approach. The midV dose distribution was blurred using the respiratory-induced motion from 4-dimensional computed tomography. The resulting planning target volume (PTV) coverage for this blurred dosemore » distribution was analyzed; PTV coverage was required to be at least V{sub 95%} >98%. In addition, the change in PTV size and the changes in V{sub 10Gy}, V{sub 20Gy}, V{sub 30Gy}, V{sub 40Gy}, D{sub mean} and D{sub 2cc} for the stomach and for the duodenum were analyzed; differences were tested for significance using the Wilcoxon signed-rank test. Results: Using a midV approach resulted in sufficient target coverage. A highly significant PTV size reduction of 13.9% (P<.001) was observed. Also, all dose parameters for the stomach and duodenum, except the D{sub 2cc} of the duodenum, improved significantly (P≤.002). Conclusions: By using the midV approach to account for respiratory-induced tumor motion, a significant PTV reduction and significant dose reductions to the stomach and to the duodenum can be achieved when irradiating pancreatic tumors.« less
NASA Astrophysics Data System (ADS)
Bollmann, T. A.; van der Lee, S.; Frederiksen, A. W.; Wolin, E.; Aleqabi, G. I.; Revenaugh, J.; Wiens, D. A.; Darbyshire, F. A.
2014-12-01
The Superior Province Rifting Earthscope Experiment (SPREE) and the northern midwest footprint of USArray's Transportable Array recorded continuous ground motion for a period of 2.5 years. From around 400 M>5.5 teleseismic earthquakes recorded at 337 stations, we measured body wave delay times for 255 of these earthquakes. The P wave delays are accumulated over more than 45 thousand wave paths with turning points in the lower mantle. We combine these delay times with a similar number delay times used in previous tomographic studies of the study region. The latter delay times stem from fewer stations, including Polaris and CNSN stations, and nearly a thousand earthquakes. We combine these two sets of delay times to image the three-dimensional distribution of seismic velocity variations beneath the southern Superior Province and surrounding provinces. This combined data coverage is illustrated in the accompanying figure for a total number of 447 stations . The coverage and the combined delays form the best configuration yet to image the three-dimensional distribution of seismic P and S-wave velocity variations beneath the southern Superior and surrounding provinces. Closely spaced stations (~12 km) along and across the MRS provide higher resolving power for lithospheric structure beneath the rift system. Conforming to expectations that the entire region is underlain by thick, cool lithosphere, a mean delay of -.55 +/- .54 s. This is very similar to the mean delays -.6s +/- .37s measured for this region before 2012. Event corrections range from -.2 +/-.54 s and correlate with tectonics for 80% of the earthquakes. An inversion of these nearly one hundred thousand P and around thirty thousand S-wave delay times for high-resolution P and S-wave velocity structure, respectively, does not show structures that are obviously related to the crustal signature of the MRS. None of structures imaged, align with or have a similar shape to the high Mid-continent Gravity Anomaly (MGA). However, a low-velocity structure is imaged in the lithosphere just east of the MGA.
Ranger, A; Dunlop, A; Hutchinson, K; Convery, H; Maclennan, M K; Chantler, H; Twyman, N; Rose, C; McQuaid, D; Amos, R A; Griffin, C; deSouza, N M; Donovan, E; Harris, E; Coles, C E; Kirby, A
2018-06-01
Radiotherapy target volumes in early breast cancer treatment increasingly include the internal mammary chain (IMC). In order to maximise survival benefits of IMC radiotherapy, doses to the heart and lung should be minimised. This dosimetry study compared the ability of three-dimensional conformal radiotherapy, arc therapy and proton beam therapy (PBT) techniques with and without breath-hold to achieve target volume constraints while minimising dose to organs at risk (OARs). In 14 patients' datasets, seven IMC radiotherapy techniques were compared: wide tangent (WT) three-dimensional conformal radiotherapy, volumetric-modulated arc therapy (VMAT) and PBT, each in voluntary deep inspiratory breath-hold (vDIBH) and free breathing (FB), and tomotherapy in FB only. Target volume coverage and OAR doses were measured for each technique. These were compared using a one-way ANOVA with all pairwise comparisons tested using Bonferroni's multiple comparisons test, with adjusted P-values ≤ 0.05 indicating statistical significance. One hundred per cent of WT(vDIBH), 43% of WT(FB), 100% of VMAT(vDIBH), 86% of VMAT(FB), 100% of tomotherapy FB and 100% of PBT plans in vDIBH and FB passed all mandatory constraints. However, coverage of the IMC with 90% of the prescribed dose was significantly better than all other techniques using VMAT(vDIBH), PBT(vDIBH) and PBT(FB) (mean IMC coverage ± 1 standard deviation = 96.0% ± 4.3, 99.8% ± 0.3 and 99.0% ± 0.2, respectively). The mean heart dose was significantly reduced in vDIBH compared with FB for both the WT (P < 0.0001) and VMAT (P < 0.0001) techniques. There was no advantage in target volume coverage or OAR doses for PBT(vDIBH) compared with PBT(FB). Simple WT radiotherapy delivered in vDIBH achieves satisfactory coverage of the IMC while meeting heart and lung dose constraints. However, where higher isodose coverage is required, VMAT(vDIBH) is the optimal photon technique. The lowest OAR doses are achieved by PBT, in which the use of vDIBH does not improve dose statistics. Crown Copyright © 2018. Published by Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Patel, Pretesh R., E-mail: patel073@mc.duke.edu; Yoo, Sua; Broadwater, Gloria
Purpose: To assess the impact of increasing experience with intensity-modulated radiation therapy (IMRT) after extrapleural pneumonectomy (EPP) for malignant pleural mesothelioma (MPM). Methods and Materials: The records of all patients who received IMRT following EPP at Duke University Medical Center between 2005 and 2010 were reviewed. Target volumes included the preoperative extent of the pleural space, chest wall incisions, involved nodal stations, and a boost to close/positive surgical margins if applicable. Patients were typically treated with 9-11 beams with gantry angles, collimator rotations, and beam apertures manually fixed to avoid the contalateral lung and to optimize target coverage. Toxicity wasmore » graded retrospectively using National Cancer Institute common toxicity criteria version 4.0. Target coverage and contralateral lung irradiation were evaluated over time by using linear regression. Local control, disease-free survival, and overall survival rates were estimated using the Kaplan-Meier method. Results: Thirty patients received IMRT following EPP; 21 patients also received systemic chemotherapy. Median follow-up was 15 months. The median dose prescribed to the entire ipsilateral hemithorax was 45 Gy (range, 40-50.4 Gy) with a boost of 8-25 Gy in 9 patients. Median survival was 23.2 months. Two-year local control, disease-free survival, and overall survival rates were 47%, 34%, and 50%, respectively. Increasing experience planning MPM cases was associated with improved coverage of planning target volumes (P=.04). Similarly, mean lung dose (P<.01) and lung V5 (volume receiving 5 Gy or more; P<.01) values decreased with increasing experience. Lung toxicity developed after IMRT in 4 (13%) patients at a median of 2.2 months after RT (three grade 3-4 and one grade 5). Lung toxicity developed in 4 of the initial 15 patients vs none of the last 15 patients treated. Conclusions: With increasing experience, target volume coverage improved and dose to the contralateral lung decreased. Rates of pulmonary toxicity were relatively low. However, both local and distant control rates remained suboptimal.« less
Parker, Lucy A; Rumunu, John; Jamet, Christine; Kenyi, Yona; Lino, Richard Laku; Wamala, Joseph F; Mpairwe, Allan M; Muller, Vincent; Llosa, Augusto E; Uzzeni, Florent; Luquero, Francisco J; Ciglenecki, Iza; Azman, Andrew S
2017-06-01
In June 2015, a cholera outbreak was declared in Juba, South Sudan. In addition to standard outbreak control measures, oral cholera vaccine (OCV) was proposed. As sufficient doses to cover the at-risk population were unavailable, a campaign using half the standard dosing regimen (one-dose) targeted high-risk neighborhoods and groups including neighbors of suspected cases. Here we report the operational details of this first public health use of a single-dose regimen of OCV and illustrate the feasibility of conducting highly targeted vaccination campaigns in an urban area. Neighborhoods of the city were prioritized for vaccination based on cumulative attack rates, active transmission and local knowledge of known cholera risk factors. OCV was offered to all persons older than 12 months at 20 fixed sites and to select groups, including neighbors of cholera cases after the main campaign ('case-triggered' interventions), through mobile teams. Vaccination coverage was estimated by multi-stage surveys using spatial sampling techniques. 162,377 individuals received a single-dose of OCV in the targeted neighborhoods. In these neighborhoods vaccine coverage was 68.8% (95% Confidence Interval (CI), 64.0-73.7) and was highest among children ages 5-14 years (90.0%, 95% CI 85.7-94.3), with adult men being less likely to be vaccinated than adult women (Relative Risk 0.81, 95% CI: 0.68-0.96). In the case-triggered interventions, each lasting 1-2 days, coverage varied (range: 30-87%) with an average of 51.0% (95% CI 41.7-60.3). Vaccine supply constraints and the complex realities where cholera outbreaks occur may warrant the use of flexible alternative vaccination strategies, including highly-targeted vaccination campaigns and single-dose regimens. We showed that such campaigns are feasible. Additional work is needed to understand how and when to use different strategies to best protect populations against epidemic cholera.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Moignier, Alexandra, E-mail: alexandra-moignier@uiowa.edu; Gelover, Edgar; Wang, Dongxu
Purpose: To quantify the dosimetric benefit of using a dynamic collimation system (DCS) for penumbra reduction during the treatment of brain tumors by pencil beam scanning proton therapy (PBS PT). Methods and Materials: Collimated and uncollimated brain treatment plans were created for 5 patients previously treated with PBS PT and retrospectively enrolled in an institutional review board–approved study. The in-house treatment planning system, RDX, was used to generate the plans because it is capable of modeling both collimated and uncollimated beamlets. The clinically delivered plans were reproduced with uncollimated plans in terms of target coverage and organ at risk (OAR) sparingmore » to ensure a clinically relevant starting point, and collimated plans were generated to improve the OAR sparing while maintaining target coverage. Physical and biological comparison metrics, such as dose distribution conformity, mean and maximum doses, normal tissue complication probability, and risk of secondary brain cancer, were used to evaluate the plans. Results: The DCS systematically improved the dose distribution conformity while preserving the target coverage. The average reduction of the mean dose to the 10-mm ring surrounding the target and the healthy brain were 13.7% (95% confidence interval [CI] 11.6%-15.7%; P<.0001) and 25.1% (95% CI 16.8%-33.4%; P<.001), respectively. This yielded an average reduction of 24.8% (95% CI 0.8%-48.8%; P<.05) for the brain necrosis normal tissue complication probability using the Flickinger model, and 25.1% (95% CI 16.8%-33.4%; P<.001) for the risk of secondary brain cancer. A general improvement of the OAR sparing was also observed. Conclusion: The lateral penumbra reduction afforded by the DCS increases the normal tissue sparing capabilities of PBS PT for brain cancer treatment while preserving target coverage.« less
Accurate and exact CNV identification from targeted high-throughput sequence data.
Nord, Alex S; Lee, Ming; King, Mary-Claire; Walsh, Tom
2011-04-12
Massively parallel sequencing of barcoded DNA samples significantly increases screening efficiency for clinically important genes. Short read aligners are well suited to single nucleotide and indel detection. However, methods for CNV detection from targeted enrichment are lacking. We present a method combining coverage with map information for the identification of deletions and duplications in targeted sequence data. Sequencing data is first scanned for gains and losses using a comparison of normalized coverage data between samples. CNV calls are confirmed by testing for a signature of sequences that span the CNV breakpoint. With our method, CNVs can be identified regardless of whether breakpoints are within regions targeted for sequencing. For CNVs where at least one breakpoint is within targeted sequence, exact CNV breakpoints can be identified. In a test data set of 96 subjects sequenced across ~1 Mb genomic sequence using multiplexing technology, our method detected mutations as small as 31 bp, predicted quantitative copy count, and had a low false-positive rate. Application of this method allows for identification of gains and losses in targeted sequence data, providing comprehensive mutation screening when combined with a short read aligner.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jiang, Runqing; Zhan, Lixin; Osei, Ernest
2014-08-15
Volumetric modulated arc therapy (VMAT) allows fast delivery of stereotactic radiotherapy. However, the discrepancies between the calculated and delivered dose distributions due to respiratory motion and dynamic multileaf collimators (MLCs) interplay are not avoidable. The purpose of this study is to investigate RapidArc lung SBRT treatment delivered by the flattening filter-free (FFF) beam and flattened beam with Varian TrueBeam machine. CIRS Dynamic Thorax Phantom with in-house made lung tumor insertion was CT scanned both in free breathing and 4DCT. 4DCT was used to determine the internal target volume. The free breathing CT scan was used for treatment planning. A 5more » mm margin was given to ITV to generate a planning target volume. Varian Eclipse treatment planning was used to generate RapidArc plans based on the 6 MV flattened beam and 6MV FFF beam. The prescription dose was 48 Gy in 4 fractions. At least 95% of PTV was covered by the prescribed dose. The RapidArc plans with 6 MV flattened beam and 6MV FFF beam were delivered with Varian TrueBeam machine. The dosimetric measurements were performed with Gafchromic XR-RV3 film, which was placed in the lung tumor insertion. The interplay between the dynamic MLC-based delivery of VMAT and the respiratory motion of the tumor degraded target coverage and created undesired hot or cold dose spots inside the lung tumor. Lung SBRT RapidArc treatments delivered by the FFF beam of TrueBeam linear accelerator is superior to the flattened beam. Further investigation will be performed by Monte Carlo simulation.« less
Giladi, Eilath E; Klar, Yechiel
2002-12-01
People are frequently required to judge how particular group members measure up against others in their group. According to the local-comparisons-general-standards (LOGE) approach, in these member-to-group comparisons, people fail to use the normatively appropriate local (group) standard and are infelicitously affected by a more general standard (involving instances from outside the judged group). Within positive groups, target group members are judged superior to the other members of the group, and within negative groups, inferior. To date, these nonselective superiority and inferiority biases have been demonstrated solely in judgments about human beings. In 6 experiments, nonselective biases were found in perceptual, affective, and cognitive judgments of nonhuman targets, objects, and concepts, thus supporting a cognitive rather than a social account.
Superior stability for perovskite solar cells with 20% efficiency using vacuum co-evaporation.
Zhu, Xuejie; Yang, Dong; Yang, Ruixia; Yang, Bin; Yang, Zhou; Ren, Xiaodong; Zhang, Jian; Niu, Jinzhi; Feng, Jiangshan; Liu, Shengzhong Frank
2017-08-31
Chemical composition and film quality are two key figures of merit for large-area high-efficiency perovskite solar cells. To date, all studies on mixed perovskites have used solution-processing, which results in imperfect surface coverage and pin-holes generated during solvent evaporation, execrably influencing the stability and efficiency of perovskite solar cells. Herein, we report our development using a vacuum co-evaporation deposition method to fabricate pin-hole-free cesium (Cs)-substituted perovskite films with complete surface coverage. Apart from the simplified procedure, the present method also promises tunable band gap, reduced trap-state density and longer carrier lifetime, leading to solar cell efficiency as high as 20.13%, which is among the highest reported for planar perovskite solar cells. The splendid performance is attributed to superior merits of the Cs-substituted perovskite film including tunable band gap, reduced trap-state density and longer carrier lifetime. Moreover, the Cs-substituted perovskite device without encapsulation exhibits significantly higher stability in ambient air compared with the single-component counterpart. When the Cs-substituted perovskite solar cells are stored in dark for one year, the PCE remains at 19.25%, degrading only 4.37% of the initial efficiency. The excellent stability originates from reduced lattice constant and relaxed strain in perovskite lattice by incorporating Cs cations into the crystal lattice, as demonstrated by the positive peak shifts and reduced peak width in X-ray diffraction analysis.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cao Junsheng; Roeske, John C.; Chmura, Steve J.
2009-07-01
The standard treatment technique used for whole-breast irradiation can result in undesirable dose distributions in the treatment site, leading to skin reaction/fibrosis and pulmonary and cardiac toxicities. Hence, the technique has evolved from conventional wedged technique (CWT) to segment intensity-modulated radiation therapy (SIMRT) and beamlet IMRT (IMRT). However, these newer techniques feature more highly modulated dose distributions that may be affected by respiration. The purpose of this work was to conduct a simple study of the clinical impact of respiratory motion on breast radiotherapy dose distributions for the three treatment planning techniques. The ultimate goal was to determine which patientsmore » would benefit most from the use of motion management. Eight patients with early-stage breast cancer underwent a free-breathing (FB) computed tomography (CT) simulation, with medial and lateral markers placed on the skin. Two additional CT scans were obtained at the end of inspiration (EI) and the end of expiration (EE). The FB-CT scan was used to develop treatment plans using each technique. Each plan was then applied to EI and EE-CT scans. Compared with the FB CT scan, the medial markers moved up to 1.8 cm in the anterior-superior direction at the end of inspiration (EI-scan), and on average 8 mm. The CWT and SIMRT techniques were not 'sensitive' to respiratory motion, because the % clinical target volume (CTV) receiving 95% of the prescription dose (V{sub 95%}) remained constant for both techniques. For patients that had large respiratory motion indicated by marker movement >0.6 cm, differences in coverage of the CTV at the V100% between FB and EI for beamlet IMRT plans were on the order of >10% and up to 18%. A linear model was developed to relate the dosimetric coverage difference introduced by respiration with the motion information. With this model, the dosimetric coverage difference introduced by respiratory motion could be evaluated during patient CT simulation. An appropriate treatment method can be chosen after the simulation.« less
SU-F-T-443: Quantification of Dosimetric Effects of Dental Metallic Implant On VMAT Plans
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lin, C; Jiang, W; Feng, Y
Purpose: To evaluate the dosimetric impact of metallic implant that correlates with the size of targets and metallic implants and distance in between on volumetric-modulated arc therapy (VMAT) plans for head and neck (H&N) cancer patients with dental metallic implant. Methods: CT images of H&N cancer patients with dental metallic implant were used. Target volumes with different sizes and locations were contoured. Metal artifact regions excluding surrounding critical organs were outlined and assigned with CT numbers close to water (0HU). VMAT plans with half-arc, one-full-arc and two-full-arcs were constructed and same plans were applied to structure sets with and withoutmore » CT number assignment of metal artifact regions and compared. D95% was utilized to investigate PTV dose coverage and SNC Patient− Software was used for the analysis of dose distribution difference slice by slice. Results: For different targets sizes, variation of PTV dose coverage (Delta-D95%) with and without CT number replacement reduced with larger target volume for all half-arc, one-arc and two-arc VMAT plans even though there were no clinically significant differences. Additionally, there were no significant variations of the maximum percent difference (max.%diff) of dose distribution. With regard to the target location, Delta-D95% and max. %diff dropped with increasing distance between target and metallic implant. Furthermore, half-arc plans showed greater impact than one-arc plans, and two-arc plans had smallest influence for PTV dose coverage and dose distribution. Conclusion: The target size has less correlation of doseimetric impact than the target location relative to metallic implants. Plans with more arcs alleviate the dosimetric effect of metal artifact because of less contribution to the target dose from beams going through the regions with metallic artifacts. Incorrect CT number causes inaccurate dose distribution, therefore appropriately overwriting metallic artifact regions with reasonable CT numbers is recommended. More patient data are collected and under further analysis.« less
Cha, Seungman; Mankadi, Paul Mansiangi; Elhag, Mousab Siddig; Lee, Yongjoo; Jin, Yan
2017-01-01
ABSTRACT Background: As the Millennium Development Goals ended, and were replaced by the Sustainable Development Goals, efforts have been made to evaluate the achievements and performance of official development assistance (ODA) in the health sector. In this study, we explore trends in the expansion of water and sanitation coverage in developing countries and the performance of ODA. Design: We explored inequality across developing countries by income level, and investigated how ODA for water and sanitation was committed by country, region, and income level. Changes in inequality were tested via slope changes by investigating the interaction of year and income level with a likelihood ratio test. A random effects model was applied according to the results of the Hausman test. Results: The slope of the linear trend between economic level and sanitation coverage has declined over time. However, a random effects model suggested that the change in slope across years was not significant (e.g. for the slope change between 2000 and 2010: likelihood ratio χ2 = 2.49, probability > χ2 = 0.1146). A similar pro-rich pattern across developing countries and a non-significant change in the slope associated with different economic levels were demonstrated for water coverage. Our analysis shows that the inequality of water and sanitation coverage among countries across the world has not been addressed effectively during the past decade. Our findings demonstrate that the countries with the least coverage persistently received far less ODA per capita than did countries with much more extensive water and sanitation coverage, suggesting that ODA for water and sanitation is poorly targeted. Conclusion: The most deprived countries should receive more attention for water and sanitation improvements from the world health community. A strong political commitment to ODA targeting the countries with the least coverage is needed at the global level. PMID:28604256
SU-E-T-333: Dosimetric Impact of Rotational Error On the Target Coverage in IMPT Lung Cancer Plans
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rana, S; Zheng, Y
2015-06-15
Purpose: The main purpose of this study was to investigate the impact of rotational (yaw, roll, and pitch) error on the planning target volume (PTV) coverage in lung cancer plans generated by intensity modulated proton therapy (IMPT). Methods: In this retrospective study, computed tomography (CT) dataset of previously treated lung case was used. IMPT plan were generated on the original CT dataset using left-lateral (LL) and posterior-anterior (PA) beams for a total dose of 74 Gy[RBE] with 2 Gy[RBE] per fraction. In order to investigate the dosimetric impact of rotational error, 12 new CT datasets were generated by re-sampling themore » original CT dataset for rotational (roll, yaw, and pitch) angles ranged from −5° to +5°, with an increment of 2.5°. A total of 12 new IMPT plans were generated based on the re-sampled CT datasets using beam parameters identical to the ones in the original IMPT plan. All treatment plans were generated in XiO treatment planning system. The PTV coverage (i.e., dose received by 95% of the PTV volume, D95) in new IMPT plans were then compared with the PTV coverage in the original IMPT plan. Results: Rotational errors caused the reduction in the PTV coverage in all 12 new IMPT plans when compared to the original IMPT lung plan. Specifically, the PTV coverage was reduced by 4.94% to 50.51% for yaw, by 4.04% to 23.74% for roll, and by 5.21% to 46.88% for pitch errors. Conclusion: Unacceptable dosimetric results were observed in new IMPT plans as the PTV coverage was reduced by up to 26.87% and 50.51% for rotational error of 2.5° and 5°, respectively. Further investigation is underway in evaluating the PTV coverage loss in the IMPT lung cancer plans for smaller rotational angle change.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dormer, J; Kassaee, A; Lin, H
2014-06-01
Purpose: To evaluate use of intensity modulated proton therapy (IMPT) and number of beams for sparing cochlea in treatment of whole brain for pediatric medulloblastoma patients. Methods: In our institution, craniospinal irradiation patients are treated in supine position on our proton gantries using pencil beam scanning with each beam uniformly covering the target volume (SFUD). Each treatment plan consists of two opposed lateral whole brain fields and one or two spinal fields. For sparing the cochlea for the whole brain treatment, we created three different plans using IMPT for five pediatric patients. The first plan consisted of two lateral fields,more » the second two lateral fields and a superior-inferior field, and the third two lateral fields and two superior oblique fields. Optimization was performed with heavy weights applied to the eye, lens and cochlea while maintaining a dose prescription of 36 Gy to the whole brain. Results: IMPT plans reduce the dose to the cochlea. Increasing the number of treatment fields was found to lower the average dose to the cochlea: 15.0, 14.5 and 12.5 Gy for the two-field, three-field, and four-field plans respectively. The D95 for the two-field plan was 98.2%, compared to 100.0% for both the three-field and four-field plan. Coverage in the mid-brain was noticeably better in the three- and four-field plans, with more dose conformality surrounding the cochlea. Conclusion: IMPT plans for CSI and the whole brain irradiations are capable of sparing cochlea and reduce the dose considerably without compromising treating brain tissues. The reduction in average dose increases with three and four field plans as compared to traditional two lateral beam plans.« less
Wehby, George L; Lyu, Wei
2018-04-01
Examine the ACA Medicaid expansion effects on Medicaid take-up and private coverage through 2015 and coverage disparities by age, race/ethnicity, and gender. 2011-2015 American Community Survey for 3,137,989 low-educated adults aged 19-64 years. Difference-in-differences regressions accounting for national coverage trends and state fixed effects. Expansion effects doubled in 2015 among low-educated adults, with a nearly 8 percentage-point increase in Medicaid take-up and 6 percentage-point decline in uninsured rate. Significant coverage gains were observed across virtually all examined groups by age, gender, and race/ethnicity. Take-up and insurance declines were strongest among younger adults and were generally close by gender and race/ethnicity. Despite the increased take-up however, coverage disparities remained sizeable, especially for young adults and Hispanics who had declining but still high uninsured rates in 2015. There was some evidence of private coverage crowd-out in certain subgroups, particularly among young adults aged 19-26 years and women, including in both individually purchased and employer-sponsored coverage. The ACA Medicaid expansions have continued to increase coverage in 2015 across the entire population of low-educated adults and have reduced age disparities in coverage. However, there is still a need for interventions that target eligible young and Hispanic adults. © Health Research and Educational Trust.
Deployment of spatial attention to words in central and peripheral vision.
Ducrot, Stéphanie; Grainger, Jonathan
2007-05-01
Four perceptual identification experiments examined the influence of spatial cues on the recognition of words presented in central vision (with fixation on either the first or last letter of the target word) and in peripheral vision (displaced left or right of a central fixation point). Stimulus location had a strong effect on word identification accuracy in both central and peripheral vision, showing a strong right visual field superiority that did not depend on eccentricity. Valid spatial cues improved word identification for peripherally presented targets but were largely ineffective for centrally presented targets. Effects of spatial cuing interacted with visual field effects in Experiment 1, with valid cues reducing the right visual field superiority for peripherally located targets, but this interaction was shown to depend on the type of neutral cue. These results provide further support for the role of attentional factors in visual field asymmetries obtained with targets in peripheral vision but not with centrally presented targets.
Fogliata, Antonella; Scorsetti, Marta; Navarria, Piera; Catalano, Maddalena; Clivio, Alessandro; Cozzi, Luca; Lobefalo, Francesca; Nicolini, Giorgia; Palumbo, Valentina; Pellegrini, Chiara; Reggiori, Giacomo; Roggio, Antonella; Vanetti, Eugenio; Alongi, Filippo; Pentimalli, Sara; Mancosu, Pietro
2013-04-01
To appraise the potential of volumetric modulated arc therapy (VMAT, RapidArc) and proton beams to simultaneously achieve target coverage and enhanced sparing of bone tissue in the treatment of soft-tissue sarcoma with adequate target coverage. Ten patients presenting with soft-tissue sarcoma of the leg were collected for the study. Dose was prescribed to 66.5 Gy in 25 fractions to the planning target volume (PTV) while significant maximum dose to the bone was constrained to 50 Gy. Plans were optimised according to the RapidArc technique with 6 MV photon beams or for intensity modulated protons. RapidArc photon plans were computed with: 1) AAA; 2) Acuros XB as dose to medium; and 3) Acuros XB as dose to water. All plans acceptably met the criteria of target coverage (V95% >90-95%) and bone sparing (D(1 cm3) <50 Gy). Significantly higher PTV dose homogeneity was found for proton plans. Near-to-maximum dose to bone was similar for RapidArc and protons, while volume receiving medium/low dose levels was minimised with protons. Similar results were obtained for the remaining normal tissue. Dose distributions calculated with the dose to water option resulted ~5% higher than corresponding ones computed as dose to medium. High plan quality was demonstrated for both VMAT and proton techniques when applied to soft-tissue sarcoma.
Park, S
2000-07-01
The superior gluteal vessel has been reported as a recipient in free-tissue transfer for the coverage of complex soft-tissue defects in the lumbosacral region, where a suitable recipient vessel is difficult to find. The characteristics of proximity, vessel caliber, and constancy make the superior gluteal vessel preferable to previously reported recipient vessels. However, there are technical difficulties in microsurgery (e.g., short pedicle length and deep location) and muscle injury (transection of the muscle) associated with use of the superior gluteal vessel. The purpose of this article is to present a modification of an approach to the gluteal vessel to alleviate technical difficulties and minimize muscle injury. From August of 1997 to January of 1999, six patients received microvascular transfer of the latissimus dorsi muscle or myocutaneous flap to the sacral (4) and ischial (2) regions. The causes of defects were tumor (1), trauma (1), and pressure sores (4). A muscle-splitting approach was used on the superior gluteal vessel and was later applied to the inferior gluteal vessel. The gluteus maximus muscle was split as needed in the direction of its fibers, and the perforators were dissected down to the superior or inferior gluteal artery and vein deep into the muscle. The follow-up period ranged from 6 to 22 months, and all of the flaps survived with complete recovery of the lesion. The major drawbacks of using the superior and inferior gluteal vessels can be overcome with the muscle-splitting approach, which provides increased accessibility and additional length to the vascular pedicle while causing minimal injury to the muscle itself. It also proves to be an easy, safe, and reliable method of dissection. When free-tissue transfer to sacral, gluteal, and ischial regions is indicated, the muscle-splitting approach to the superior and inferior gluteal vessels is a recommended option in the selection of a recipient vessel.
Nájera-Aguilar, P; Infante-Castañeda, C
1990-01-01
Less than a third of the non-insured population studied through a sample in the State of Mexico was covered by the Institute of Health of the State of México. This low coverage was observed in spite the fact that health services were available within 2 kilometer radius. 33 per cent of the non-insured preferred to utilize other services within their own community, and 24 per cent of them traveled to bigger localities to receive care. These results suggest that to attain adequate coverage, utilization patterns should be investigated so that health services can meet the needs of the target population.
A catalog of putative adverse outcome pathways (AOPs) that ...
A number of putative AOPs for several distinct MIEs of thyroid disruption have been formulated for amphibian metamorphosis and fish swim bladder inflation. These have been entered into the AOP knowledgebase on the OECD WIKI. The EDSP has been actively advancing high-throughput screening for chemical activity toward estrogen, androgen and thyroid targets. However, it has been recently identified that coverage for thyroid-related targets is lagging behind estrogen and androgen assay coverage. As thyroid-related medium-high throughput assays are actively being developed for inclusion in the ToxCast chemical screening program, a parallel effort is underway to characterize putative adverse outcome pathways (AOPs) specific to these thyroid-related targets. This effort is intended to provide biological and ecological context that will enhance the utility of ToxCast high throughput screening data for hazard identification.
Masanja, Honorati; Schellenberg, Joanna Armstrong; Mshinda, Hassan M; Shekar, Meera; Mugyabuso, Joseph K L; Ndossi, Godwin D; de Savigny, Don
2006-11-01
Efficient delivery strategies for health interventions are essential for high and sustainable coverage. We report impact of a change in programmatic delivery strategy from routine delivery through the Expanded Programme on Immunization (EPI+) approach to twice-yearly mass distribution campaigns on coverage of vitamin A supplementation in Tanzania We investigated disparities in age, sex, socio-economic status, nutritional status and maternal education within vitamin A coverage in children between 1 and 2 years of age from two independent household level child health surveys conducted (1) during a continuous universal targeting scheme based on routine EPI contacts for children aged 9, 15 and 21 months (1999); and (2) three years later after the introduction of twice-yearly vitamin A supplementation campaigns for children aged 6 months to 5 years, a 6-monthly universal targeting scheme (2002). A representative cluster sample of approximately 2,400 rural households was obtained from Rufiji, Morogoro Rural, Kilombero and Ulanga districts. A modular questionnaire about the health of all children under the age of five was administered to consenting heads of households and caretakers of children. Information on the use of child health interventions including vitamin A was asked. Coverage of vitamin A supplementation among 1-2 year old children increased from 13% [95% CI 10-18%] in 1999 to 76% [95%CI 72-81%] in 2002. In 2002 knowledge of two or more child health danger signs was negatively associated with vitamin A supplementation coverage (80% versus 70%) (p = 0.04). Nevertheless, we did not find any disparities in coverage of vitamin A by district, gender, socio-economic status and DPT vaccinations. Change in programmatic delivery of vitamin A supplementation was associated with a major improvement in coverage in Tanzania that was been sustained by repeated campaigns for at least three years. There is a need to monitor the effect of such campaigns on the routine health system and on equity of coverage. Documentation of vitamin A supplementation campaign contacts on routine maternal and child health cards would be a simple step to facilitate this monitoring.
Effectiveness of interventions that apply new media to improve vaccine uptake and vaccine coverage.
Odone, Anna; Ferrari, Antonio; Spagnoli, Francesca; Visciarelli, Sara; Shefer, Abigail; Pasquarella, Cesira; Signorelli, Carlo
2015-01-01
Vaccine-preventable diseases (VPD) are still a major cause of morbidity and mortality worldwide. In high and middle-income settings, immunization coverage is relatively high. However, in many countries coverage rates of routinely recommended vaccines are still below the targets established by international and national advisory committees. Progress in the field of communication technology might provide useful tools to enhance immunization strategies. To systematically collect and summarize the available evidence on the effectiveness of interventions that apply new media to promote vaccination uptake and increase vaccination coverage. We conducted a systematic literature review. Studies published from January 1999 to September 2013 were identified by searching electronic resources (Pubmed, Embase), manual searches of references and expert consultation. Study setting We focused on interventions that targeted recommended vaccinations for children, adolescents and adults and: (1) aimed at increasing community demand for immunizations, or (2) were provider-based interventions. We limited the study setting to countries that are members of the Organisation for Economic Co-operation and Development (OECD). The primary outcome was a measure of vaccination (vaccine uptake or vaccine coverage). Considered secondary outcomes included willingness to receive immunization, attitudes and perceptions toward vaccination, and perceived helpfulness of the intervention. Nineteen studies were included in the systematic review. The majority of the studies were conducted in the US (74%, n = 14); 68% (n = 13) of the studies were experimental, the rest having an observational study design. Eleven (58%) reported results on the primary outcome. Retrieved studies explored the role of: text messaging (n.7, 37%), smartphone applications (n.1, 5%), Youtube videos (n.1, 5%), Facebook (n.1, 5%), targeted websites and portals (n.4, 21%), software for physicians and health professionals (n.4, 21%), and email communication (n.1, 5%). There is some evidence that text messaging, accessing immunization campaign websites, using patient-held web-based portals and computerized reminders increase immunization coverage rates. Insufficient evidence is available on the use of social networks, email communication and smartphone applications. Although there is great potential for improving vaccine uptake and vaccine coverage by implementing programs and interventions that apply new media, scant data are available and further rigorous research - including cost-effectiveness assessments - is needed.
Kiware, Samson S; Corliss, George; Merrill, Stephen; Lwetoijera, Dickson W; Devine, Gregor; Majambere, Silas; Killeen, Gerry F
2015-01-01
Large-cage experiments indicate pyriproxifen (PPF) can be transferred from resting sites to aquatic habitats by Anopheles arabiensis--malaria vector mosquitoes to inhibit emergence of their own offspring. PPF coverage is amplified twice: (1) partial coverage of resting sites with PPF contamination results in far higher contamination coverage of adult mosquitoes because they are mobile and use numerous resting sites per gonotrophic cycle, and (2) even greater contamination coverage of aquatic habitats results from accumulation of PPF from multiple oviposition events. Deterministic mathematical models are described that use only field-measurable input parameters and capture the biological processes that mediate PPF autodissemination. Recent successes in large cages can be rationalized, and the plausibility of success under full field conditions can be evaluated a priori. The model also defines measurable properties of PPF delivery prototypes that may be optimized under controlled experimental conditions to maximize chances of success in full field trials. The most obvious flaw in this model is the endogenous relationship that inevitably occurs between the larval habitat coverage and the measured rate of oviposition into those habitats if the target mosquito species is used to mediate PPF transfer. However, this inconsistency also illustrates the potential advantages of using a different, non-target mosquito species for contamination at selected resting sites that shares the same aquatic habitats as the primary target. For autodissemination interventions to eliminate malaria transmission or vector populations during the dry season window of opportunity will require comprehensive contamination of the most challenging subset of aquatic habitats [Formula: see text] that persist or retain PPF activity (Ux) for only one week [Formula: see text], where Ux = 7 days). To achieve >99% contamination coverage of these habitats will necessitate values for the product of the proportional coverage of the ovipositing mosquito population with PPF contamination (CM) by the ovitrap-detectable rates of oviposition by wild mosquitoes into this subset of habitats [Formula: see text], divided by the titre of contaminated mosquitoes required to render them unproductive [Formula: see text], that approximately approach unity [Formula: see text]. The simple multiplicative relationship between CM and [Formula: see text], and the simple exponential decay effect they have upon uncontaminated aquatic habitats, allows application of this model by theoreticians and field biologists alike.
Effectiveness of interventions that apply new media to improve vaccine uptake and vaccine coverage
Odone, Anna; Ferrari, Antonio; Spagnoli, Francesca; Visciarelli, Sara; Shefer, Abigail; Pasquarella, Cesira; Signorelli, Carlo
2014-01-01
Background Vaccine-preventable diseases (VPD) are still a major cause of morbidity and mortality worldwide. In high and middle-income settings, immunization coverage is relatively high. However, in many countries coverage rates of routinely recommended vaccines are still below the targets established by international and national advisory committees. Progress in the field of communication technology might provide useful tools to enhance immunization strategies. Objective To systematically collect and summarize the available evidence on the effectiveness of interventions that apply new media to promote vaccination uptake and increase vaccination coverage. Design We conducted a systematic literature review. Studies published from January 1999 to September 2013 were identified by searching electronic resources (Pubmed, Embase), manual searches of references and expert consultation. Study setting We focused on interventions that targeted recommended vaccinations for children, adolescents and adults and: (1) aimed at increasing community demand for immunizations, or (2) were provider-based interventions. We limited the study setting to countries that are members of the Organisation for Economic Co-operation and Development (OECD). Main outcome measures The primary outcome was a measure of vaccination (vaccine uptake or vaccine coverage). Considered secondary outcomes included willingness to receive immunization, attitudes and perceptions toward vaccination, and perceived helpfulness of the intervention. Results Nineteen studies were included in the systematic review. The majority of the studies were conducted in the US (74%, n = 14); 68% (n = 13) of the studies were experimental, the rest having an observational study design. Eleven (58%) reported results on the primary outcome. Retrieved studies explored the role of: text messaging (n.7, 37%), smartphone applications (n.1, 5%), Youtube videos (n.1, 5%), Facebook (n.1, 5%), targeted websites and portals (n.4, 21%), software for physicians and health professionals (n.4, 21%), and email communication (n.1, 5%). There is some evidence that text messaging, accessing immunization campaign websites, using patient-held web-based portals and computerized reminders increase immunization coverage rates. Insufficient evidence is available on the use of social networks, email communication and smartphone applications. Conclusion Although there is great potential for improving vaccine uptake and vaccine coverage by implementing programs and interventions that apply new media, scant data are available and further rigorous research - including cost-effectiveness assessments - is needed. PMID:25483518
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yang, Jun; Department of Oncology, First Affiliated Hospital of Xinxiang Medical University, 88 Jiankang Road, Weihui, Henan, 453100; Ma, Lin
2016-07-01
To investigate the dosimetric characteristics of 4 SBRT-capable dose delivery systems, CyberKnife (CK), Helical TomoTherapy (HT), Volumetric Modulated Arc Therapy (VMAT) by Varian RapidArc (RA), and segmental step-and-shoot intensity-modulated radiation therapy (IMRT) by Elekta, on isolated thoracic spinal lesions. CK, HT, RA, and IMRT planning were performed simultaneously for 10 randomly selected patients with 6 body types and 6 body + pedicle types with isolated thoracic lesions. The prescription was set with curative intent and dose of either 33 Gy in 3 fractions (3F) or 40 Gy in 5F to cover at least 90% of the planning target volume (PTV),more » correspondingly. Different dosimetric indices, beam-on time, and monitor units (MUs) were evaluated to compare the advantages/disadvantages of each delivery modality. In ensuring the dose-volume constraints for cord and esophagus of the premise, CK, HT, and RA all achieved a sharp conformity index (CI) and a small penumbra volume compared to IMRT. RA achieved a CI comparable to those from CK, HT, and IMRT. CK had a heterogeneous dose distribution in the target as its radiosurgical nature with less dose uniformity inside the target. CK had the longest beam-on time and the largest MUs, followed by HT and RA. IMRT presented the shortest beam-on time and the least MUs delivery. For the body-type lesions, CK, HT, and RA satisfied the target coverage criterion in 6 cases, but the criterion was satisfied in only 3 (50%) cases with the IMRT technique. For the body + pedicle-type lesions, HT satisfied the criterion of the target coverage of ≥90% in 4 of the 6 cases, and reached a target coverage of 89.0% in another case. However, the criterion of the target coverage of ≥90% was reached in 2 cases by CK and RA, and only in 1 case by IMRT. For curative-intent SBRT of isolated thoracic spinal lesions, RA is the first choice for the body-type lesions owing to its delivery efficiency (time); the second choice is CK or HT; HT is the preferential choice for the body + pedicle-type lesions. This study suggests further clinical investigations with longer follow-up for these studied cases.« less
Djedovic, Gabriel; Metzler, Julia; Morandi, Evi M; Wachter, Tanja; Kühn, Shafreena; Pierer, Gerhard; Rieger, Ulrich M
2017-12-01
Pressure sore rates remain high in both nursing homes as well as in hospitals. Numerous surgical options are available for defect coverage in the sacral region. However, objective data is scarce as to whether a specific flap design is superior to another. Here, we aim to compare two fasciocutaneous flap designs for sacral defect coverage: the gluteal rotation flap and the gluteal V-Y flap. All primary sacral pressure sores of grades III-IV that were being covered with gluteal fasciocutaneous rotational or V-Y flaps between January 2008 and December 2014 at our institution were analysed. A total of 41 patients received a total of 52 flaps. Of these, 18 patients received 20 gluteal rotational flaps, and 23 patients received 32 V-Y flaps. Both groups were comparable with regards to demographics, comorbidities and complications. Significantly more V-Y flaps were needed to cover smaller defects. Mean length of hospital stay was significantly prolonged when surgical revision had to be carried out. Both flap designs have proven safe and reliable for defect coverage after sacral pressure sores. Gluteal rotational flaps appear to be more useful for larger defects. Both flap designs facilitate their reuse in case of pressure sore recurrence. Complication rates appear to be comparable in both designs and to the current literature. © 2017 Medicalhelplines.com Inc and John Wiley & Sons Ltd.
Guo, Yi; Lebel, R Marc; Zhu, Yinghua; Lingala, Sajan Goud; Shiroishi, Mark S; Law, Meng; Nayak, Krishna
2016-05-01
To clinically evaluate a highly accelerated T1-weighted dynamic contrast-enhanced (DCE) MRI technique that provides high spatial resolution and whole-brain coverage via undersampling and constrained reconstruction with multiple sparsity constraints. Conventional (rate-2 SENSE) and experimental DCE-MRI (rate-30) scans were performed 20 minutes apart in 15 brain tumor patients. The conventional clinical DCE-MRI had voxel dimensions 0.9 × 1.3 × 7.0 mm(3), FOV 22 × 22 × 4.2 cm(3), and the experimental DCE-MRI had voxel dimensions 0.9 × 0.9 × 1.9 mm(3), and broader coverage 22 × 22 × 19 cm(3). Temporal resolution was 5 s for both protocols. Time-resolved images and blood-brain barrier permeability maps were qualitatively evaluated by two radiologists. The experimental DCE-MRI scans showed no loss of qualitative information in any of the cases, while achieving substantially higher spatial resolution and whole-brain spatial coverage. Average qualitative scores (from 0 to 3) were 2.1 for the experimental scans and 1.1 for the conventional clinical scans. The proposed DCE-MRI approach provides clinically superior image quality with higher spatial resolution and coverage than currently available approaches. These advantages may allow comprehensive permeability mapping in the brain, which is especially valuable in the setting of large lesions or multiple lesions spread throughout the brain.
Newspaper coverage of mental illness in England 2008-2011.
Thornicroft, Amalia; Goulden, Robert; Shefer, Guy; Rhydderch, Danielle; Rose, Diana; Williams, Paul; Thornicroft, Graham; Henderson, Claire
2013-04-01
Better newspaper coverage of mental health-related issues is a target for the Time to Change (TTC) anti-stigma programme in England, whose population impact may be influenced by how far concurrent media coverage perpetuates stigma and discrimination. To compare English newspaper coverage of mental health-related topics each year of the TTC social marketing campaign (2009-2011) with baseline coverage in 2008. Content analysis was performed on articles in 27 local and national newspapers on two randomly chosen days each month. There was a significant increase in the proportion of anti-stigmatising articles between 2008 and 2011. There was no concomitant proportional decrease in stigmatising articles, and the contribution of mixed or neutral elements decreased. These findings provide promising results on improvements in press reporting of mental illness during the TTC programme in 2009-2011, and a basis for guidance to newspaper journalists and editors on reporting mental illness.
2018-01-30
algorithms. Due to this, Fusion was built with the goal of extensibility throughout the architecture. The Fusion infrastructure enables software...DISTRIBUTION STATEMENT A: Approved for public release. Cleared, 88PA, Case# 2018-0820. b. Trigger a Highly Mobile ...modes were developed in IMPACT (i.e., normal full coverage patrol (NFCP) and highly mobile (HM)). In both NFCP and HM, all UxVs patrol their assigned
DOE Office of Scientific and Technical Information (OSTI.GOV)
Reed, W.P.; Spence, R.J.
We have used a contralateral vertical rectus abdominis musculocutaneous flap based upon the superior epigastric vessels in six patients to provide coverage after resection of locally recurrent breast carcinoma in irradiated tissues. Primary healing of defects as large as 16 cm X 35 cm has been obtained using this technique. Although there is no evidence to suggest that such a procedure significantly lengthens survival, it was clearly beneficial to the quality of life in these patients. Our results suggest that older patients with relatively indolent disease receive the greatest benefit from this procedure.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Xin; Li, Guangjun; Zhang, Yingjie
2013-01-01
To compare the dosimetric differences between the single-arc volumetric-modulated arc therapy (sVMAT), 3-dimensional conformal radiotherapy (3D-CRT), and intensity-modulated radiotherapy (IMRT) techniques in treatment planning for gastric cancer as adjuvant radiotherapy. Twelve patients were retrospectively analyzed. In each patient's case, the parameters were compared based on the dose-volume histogram (DVH) of the sVMAT, 3D-CRT, and IMRT plans, respectively. Three techniques showed similar target dose coverage. The maximum and mean doses of the target were significantly higher in the sVMAT plans than that in 3D-CRT plans and in the 3D-CRT/IMRT plans, respectively, but these differences were clinically acceptable. The IMRT and sVMATmore » plans successfully achieved better target dose conformity, reduced the V{sub 20/30}, and mean dose of the left kidney, as well as the V{sub 20/30} of the liver, compared with the 3D-CRT plans. And the sVMAT technique reduced the V{sub 20} of the liver much significantly. Although the maximum dose of the spinal cord were much higher in the IMRT and sVMAT plans, respectively (mean 36.4 vs 39.5 and 40.6 Gy), these data were still under the constraints. Not much difference was found in the analysis of the parameters of the right kidney, intestine, and heart. The IMRT and sVMAT plans achieved similar dose distribution to the target, but superior to the 3D-CRT plans, in adjuvant radiotherapy for gastric cancer. The sVMAT technique improved the dose sparings of the left kidney and liver, compared with the 3D-CRT technique, but showed few dosimetric advantages over the IMRT technique. Studies are warranted to evaluate the clinical benefits of the VMAT treatment for patients with gastric cancer after surgery in the future.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jiang, Runqing; Zhan, Lixin; Osei, Ernest
2016-08-15
Introduction: The purpose of this study is to investigate the effects of daily setup variations on prone breast forward field-in-field (FinF) and inverse IMRT treatment planning. Methods: Rando Phantom (Left breast) and Pixy phantom (Right breast) were built and CT scanned in prone position. The treatment planning (TP) is performed in Eclipse TP system. Forward FinF plan and inverse IMRT plan were created to satisfy the CTV coverage and OARs criteria. The daily setup variations were assumed to be 5 mm at left-right, superior-inferior, and anterior-posterior directions. The DVHs of CTV coverage and OARs were compared for both forward FinFmore » plan and inverse IMRT plans due to 5mm setup variation. Results and Discussions: DVHs of CTV coverage had fewer variations for 5m setup variation for forward FinF and inverse IMRT plan for both phantoms. However, for the setup variations in the left-right direction, the DVH of CTV coverage of IMRT plan showed the worst variation due to lateral setup variation for both phantoms. For anterior-posterior variation, the CTV could not get full coverage when the breast chest wall is shallow; however, with the guidance of MV imaging, breast chest wall will be checked during the MV imaging setup. So the setup variations have more effects on inverse IMRT plan, compared to forward FinF plan, especially in the left-right direction. Conclusions: The Forward FinF plan was recommended clinically considering daily setup variation.« less
Gilbert, Luiram R.; Lohra, Parul; Mandlik, V.B.; Rath, S.K.; Jha, A.K.
2012-01-01
Background Esthetics represents an inseparable part of today's oral therapy, and several procedures have been proposed to preserve or enhance it. Gingival recessions may cause hypersensitivity, impaired esthetics and root caries. Keeping in mind patient's desire for improved esthetics and other related problems, every effort should be made to achieve complete root coverage. Methods Different types of modalities have been introduced to treat gingival recession including displaced flaps, free gingival graft, connective tissue graft, different type of barrier membranes and combination of different techniques. The aim of this study was to compare the commonly used techniques for gingival recession coverage and evaluate the results obtained. 73 subjects were selected for the present study who were randomly divided into four groups and were followed at baseline and 180 days where following parameters were recorded: (a) Assessment of gingival recession depth (RD); (b) Assessment of pocket depth (PD); (c) Assessment of clinical attachment level (CAL) and (d) Assessment of width of attached gingiva (WAG). Results Results of this study showed statistically significant reduction of gingival recession, with concomitant attachment gain, following treatment with all tested surgical techniques. However, SCTG with CAF technique showed the highest percentage gain in coverage of recession depth as well as gain in keratinized gingiva. Similar results were obtained with CAF alone. The use of GTR and other techniques showed less predictable coverage and gain in keratinized gingiva. Conclusion Connective tissue grafts were statistically significantly superior to guided tissue regeneration for improvement in gingival recession reduction. PMID:25609865
Hill, Holly A; Elam-Evans, Laurie D; Yankey, David; Singleton, James A; Kolasa, Maureen
2015-08-28
The reduction in morbidity and mortality associated with vaccine-preventable diseases in the United States has been described as one of the 10 greatest public health achievements of the first decade of the 21st century. A recent analysis concluded that routine childhood vaccination will prevent 322 million cases of disease and about 732,000 early deaths among children born during 1994-2013, for a net societal cost savings of $1.38 trillion. The National Immunization Survey (NIS) has monitored vaccination coverage among U.S. children aged 19-35 months since 1994. This report presents national, regional, state, and selected local area vaccination coverage estimates for children born from January 2011 through May 2013, based on data from the 2014 NIS. For most vaccinations, there was no significant change in coverage between 2013 and 2014. The exception was hepatitis A vaccine (HepA), for which increases were observed in coverage with both ≥1 and ≥2 doses. As in previous years, <1% of children received no vaccinations. National coverage estimates indicate that the Healthy People 2020 target* of 90% was met for ≥3 doses of poliovirus vaccine (93.3%), ≥1 dose of measles, mumps, and rubella vaccine (MMR) (91.5%), ≥3 doses of hepatitis B vaccine (HepB) (91.6%), and ≥1 dose of varicella vaccine (91.0%). Coverage was below target for ≥4 doses of diphtheria, tetanus, and acellular pertussis vaccine (DTaP), the full series of Haemophilus influenzae type b (Hib) vaccine, hepatitis B (HepB) birth dose,† ≥4 doses pneumococcal conjugate vaccine (PCV), ≥2 doses of HepA, the full series of rotavirus vaccine, and the combined vaccine series.§ Examination of coverage by child's race/ethnicity revealed lower estimated coverage among non-Hispanic black children compared with non-Hispanic white children for several vaccinations, including DTaP, the full series of Hib, PCV, rotavirus vaccine, and the combined series. Children from households classified as below the federal poverty level had lower estimated coverage for almost all of the vaccinations assessed, compared with children living at or above the poverty level. Significant variation in coverage by state¶ was observed for several vaccinations, including HepB birth dose, HepA, and rotavirus. High vaccination coverage must be maintained across geographic and sociodemographic groups if progress in reducing the impact of vaccine-preventable diseases is to be sustained.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lian, J; Matney, J; Chao, E
2015-06-15
Purpose: TomoTherapy treatment has unique challenges in handling intrafractional motion compared to conventional LINAC. This study is aimed to gain a realistic and quantitative understanding of motion impact on TomoTherapy SBRT treatment of lung and prostate cancer patients. Methods: A 4D dose engine utilizing GPUs and including motion during treatment was developed for the efficient simulation of TomoTherapy delivered dosimetry. Two clinical CyberKnife lung cases with respiratory motion tracking and two prostate cases with a slower non-periodical organ motion treated by LINAC plus Calypso tracking were used in the study. For each disease site, one selected case has an averagemore » motion (6mm); the other has a large motion (10mm for lung and 15mm for prostate). SBRT of lung and prostate cases were re-planned on TomoTherapy with 12 Gyx4 fractions and 7Gyx5 fractions, respectively, all with 95% PTV coverage. Each case was planned with 4 jaw settings: 1) conventional 1cm static, 2) 2.5cm static, 3) 2.5cm dynamic, and 4) 5cm dynamic. The intrafractional rigid motion of the target was applied in the dose calculation of individual fractions of each plan and total dose was accumulated from multiple fractions. Results: For 1cm static jaw plans with motions applied, PTV coverage is related to motion type and amplitude. For SBRT patients with average motion (6mm), the PTV coverage remains > 95% for lung case and 74% for prostate case. For cases with large motion, PTV coverage drops to 61% for lung SBRT and 49% for prostate SBRT. Plans with other jaws improve uniformity of moving target, but still suffer from poor PTV coverage (< 70%). Conclusion: TomoTherapy lung SBRT is less motion-impacted when average amplitude of respiratory-induced intrafractional motion is present (6mm). When motion is large and/or non-periodic (prostate), all studied plans lead to significantly decreased target coverage in actual delivered dosimetry.« less
Arbyn, Marc; Fabri, Valérie; Temmerman, Marleen; Simoens, Cindy
2014-01-01
Objective To assess the coverage for cervical cancer screening as well as the use of cervical cytology, colposcopy and other diagnostic and therapeutic interventions on the uterine cervix in Belgium, using individual health insurance data. Methods The Intermutualistic Agency compiled a database containing 14 million records from reimbursement claims for Pap smears, colposcopies, cervical biopsies and surgery, performed between 2002 and 2006. Cervical cancer screening coverage was defined as the proportion of women aged 25–64 that had a Pap smear within the last 3 years. Results Cervical cancer screening coverage was 61% at national level, for the target population of women between 25 and 64 years old, in the period 2004–2006. Differences between the 3 regions were small, but varied more substantially between provinces. Coverage was 70% for 25–34 year old women, 67% for those aged 35–39 years, and decreased to 44% in the age group of 60–64 years. The median screening interval was 13 months. The screening coverage varied substantially by social category: 40% and 64%, in women categorised as beneficiary or not-beneficiary of increased reimbursement from social insurance, respectively. In the 3-year period 2004–2006, 3.2 million screen tests were done in the target group consisting of 2.8 million women. However, only 1.7 million women got one or more smears and 1.1 million women had no smears, corresponding to an average of 1.88 smears per woman in three years of time. Colposcopy was excessively used (number of Pap smears over colposcopies = 3.2). The proportion of women with a history of conisation or hysterectomy, before the age of 65, was 7% and 19%, respectively. Conclusion The screening coverage increased slightly from 59% in 2000 to 61% in 2006. The screening intensity remained at a high level, and the number of cytological examinations was theoretically sufficient to cover more than the whole target population. PMID:24690620
Palache, A; Abelin, A; Hollingsworth, R; Cracknell, W; Jacobs, C; Tsai, T; Barbosa, P
2017-08-24
There is no global monitoring system for influenza vaccination coverage, making it difficult to assess progress towards the 2003 World Health Assembly (WHA) vaccination coverage target. In 2008, the IFPMA Influenza Vaccine Supply International Task Force (IVS) developed a survey method to assess the global distribution of influenza vaccine doses as a proxy for vaccination coverage rates. The latest dose distribution data for 2014 and 2015 was used to update previous analyses. Data were confidentially collected and aggregated by the IFPMA Secretariat, and combined with previous IFPMA IVS survey data (2004-2013). Data were available from 201 countries over the 2004-2015 period. A "hurdle" rate was defined as the number of doses required to reach 15.9% of the population in 2008. Overall, the number of distributed doses progressively increased between 2004 and 2011, driven by a 150% increase in AMRO, then plateaued. One percent fewer doses were distributed in 2015 than in 2011. Twenty-three countries were above the hurdle rate in 2015, compared to 15 in 2004, but distribution was highly uneven in and across all WHO regions. Three WHO regions (AMRO, EURO and WPRO) accounted for about 95% of doses distributed. But in EURO and WPRO, distribution rates in 2015 were only marginally higher than in 2004, and in EURO there was an overall downward trend in dose distribution. The vast majority of countries cannot meet the 2003WHA coverage targets and are inadequately prepared for a global influenza pandemic. With only 5% of influenza vaccine doses being distributed to 50% of the world's population, there is urgency to redress the gross inequities in disease prevention and in pandemic preparedness. The 2003WHA resolution must be reviewed and revised and a call issued for the renewed commitment of Member States to influenza vaccination coverage targets. Copyright © 2017. Published by Elsevier Ltd.
Ward, Zoe; Platt, Lucy; Sweeney, Sedona; Hope, Vivian D; Maher, Lisa; Hutchinson, Sharon; Palmateer, Norah; Smith, Josie; Craine, Noel; Taylor, Avril; Martin, Natasha; Ayres, Rachel; Dillon, John; Hickman, Matthew; Vickerman, Peter
2018-05-17
To estimate the impact of existing high-coverage needle and syringe provision (HCNSP, defined as obtaining more than one sterile needle and syringe per injection reported) and opioid substitution therapy (OST) on hepatitis C virus (HCV) transmission among people who inject drugs (PWID) in three UK settings and to determine required scale-up of interventions, including HCV treatment, needed to reach the World Health Organization (WHO) target of reducing HCV incidence by 90% by 2030. HCV transmission modelling using UK empirical estimates for effect of OST and/or HCNSP on individual risk of HCV acquisition. Three UK cities with varying chronic HCV prevalence (Bristol 45%, Dundee 26%, Walsall 19%), OST (72-81%) and HCNSP coverage (28-56%). Relative change in new HCV infections throughout 2016-30 if current interventions were stopped. Scale-up of HCNSP, OST and HCV treatment required to achieve the WHO elimination target. Removing HCNSP or OST would increase the number of new HCV infections throughout 2016 to 2030 by 23-64 and 92-483%, respectively. Conversely, scaling-up these interventions to 80% coverage could achieve a 29 or 49% reduction in Bristol and Walsall, respectively, whereas Dundee may achieve a 90% decrease in incidence with current levels of intervention because of existing high levels of HCV treatment (47-58 treatments per 1000 PWID). If OST and HCNSP are scaled-up, Walsall and Bristol can achieve the same impact by treating 14 or 40 per 1000 PWID annually, respectively (currently two and nine treatments per 1000 PWID), while 18 and 43 treatments per 1000 PWID would be required if OST and HCNSP are not scaled-up. Current opioid substitution therapy and high-coverage needle and syringe provision coverage is averting substantial hepatitis C transmission in the United Kingdom. Maintaining this coverage while getting current drug injectors onto treatment can reduce incidence by 90% by 2030. © 2018 The Authors. Addiction published by John Wiley & Sons Ltd on behalf of Society for the Study of Addiction.
Using lot quality assurance sampling to improve immunization coverage in Bangladesh.
Tawfik, Y.; Hoque, S.; Siddiqi, M.
2001-01-01
OBJECTIVE: To determine areas of low vaccination coverage in five cities in Bangladesh (Chittagong, Dhaka, Khulna, Rajshahi, and Syedpur). METHODS: Six studies using lot quality assurance sampling were conducted between 1995 and 1997 by Basic Support for Institutionalizing Child Survival and the Bangladesh National Expanded Programme on Immunization. FINDINGS: BCG vaccination coverage was acceptable in all lots studied; however, the proportion of lots rejected because coverage of measles vaccination was low ranged from 0% of lots in Syedpur to 12% in Chittagong and 20% in Dhaka's zones 7 and 8. The proportion of lots rejected because an inadequate number of children in the sample had been fully vaccinated varied from 11% in Syedpur to 30% in Dhaka. Additionally, analysis of aggregated, weighted immunization coverage showed that there was a high BCG vaccination coverage (the first administered vaccine) and a low measles vaccination coverage (the last administered vaccine) indicating a high drop-out rate, ranging from 14% in Syedpur to 36% in Dhaka's zone 8. CONCLUSION: In Bangladesh, where resources are limited, results from surveys using lot quality assurance sampling enabled managers of the National Expanded Programme on Immunization to identify areas with poor vaccination coverage. Those areas were targeted to receive focused interventions to improve coverage. Since this sampling method requires only a small sample size and was easy for staff to use, it is feasible for routine monitoring of vaccination coverage. PMID:11436470
A novel probabilistic approach to generating PTV with partial voxel contributions
NASA Astrophysics Data System (ADS)
Tsang, H. S.; Kamerling, C. P.; Ziegenhein, P.; Nill, S.; Oelfke, U.
2017-06-01
Radiotherapy treatment planning for use with high-energy photon beams currently employs a binary approach in defining the planning target volume (PTV). We propose a margin concept that takes the beam directions into account, generating beam-dependent PTVs (bdPTVs) on a beam-by-beam basis. The resulting degree of overlaps between the bdPTVs are used within the optimisation process; the optimiser effectively considers the same voxel to be both target and organ at risk (OAR) with fractional contributions. We investigate the impact of this novel approach when applied to prostate radiotherapy treatments, and compare treatment plans generated using beam dependent margins to conventional margins. Five prostate patients were used in this planning study, and plans using beam dependent margins improved the sparing of high doses to target-surrounding OARs, though a trade-off in delivering additional low dose to the OARs can be observed. Plans using beam dependent margins are observed to have a slightly reduced target coverage. Nevertheless, all plans are able to satisfy 90% population coverage with the target receiving at least 95% of the prescribed dose to D98% .
22 CFR Appendix I to Part 211 - Operational Plan
Code of Federal Regulations, 2010 CFR
2010-04-01
.... If there are several objectives, indicate priorities. c. Describe the target population by program... coverage and the percent of total target population reached. d. Describe the intervention including: (1... World Food Program) emergency request normally requires more Mission involvement in program design and...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Burnum-Johnson, Kristin E.; Nie, Song; Casey, Cameron P.
Current proteomics approaches are comprised of both broad discovery measurements as well as more quantitative targeted measurements. These two different measurement types are used to initially identify potentially important proteins (e.g., candidate biomarkers) and then enable improved quantification for a limited number of selected proteins. However, both approaches suffer from limitations, particularly the lower sensitivity, accuracy, and quantitation precision for discovery approaches compared to targeted approaches, and the limited proteome coverage provided by targeted approaches. Herein, we describe a new proteomics approach that allows both discovery and targeted monitoring (DTM) in a single analysis using liquid chromatography, ion mobility spectrometrymore » and mass spectrometry (LC-IMS-MS). In DTM, heavy labeled peptides for target ions are spiked into tryptic digests and both the labeled and unlabeled peptides are broadly detected using LC-IMS-MS instrumentation, allowing the benefits of discovery and targeted approaches. To understand the possible improvement of the DTM approach, it was compared to LC-MS broad measurements using an accurate mass and time tag database and selected reaction monitoring (SRM) targeted measurements. The DTM results yielded greater peptide/protein coverage and a significant improvement in the detection of lower abundance species compared to LC-MS discovery measurements. DTM was also observed to have similar detection limits as SRM for the targeted measurements indicating its potential for combining the discovery and targeted approaches.« less
NASA Astrophysics Data System (ADS)
Anderson, Monica; David, Phillip
2007-04-01
Implementation of an intelligent, automated target acquisition and tracking systems alleviates the need for operators to monitor video continuously. This system could identify situations that fatigued operators could easily miss. If an automated acquisition and tracking system plans motions to maximize a coverage metric, how does the performance of that system change when the user intervenes and manually moves the camera? How can the operator give input to the system about what is important and understand how that relates to the overall task balance between surveillance and coverage? In this paper, we address these issues by introducing a new formulation of the average linear uncovered length (ALUL) metric, specially designed for use in surveilling urban environments. This metric coordinates the often competing goals of acquiring new targets and tracking existing targets. In addition, it provides current system performance feedback to system users in terms of the system's theoretical maximum and minimum performance. We show the successful integration of the algorithm via simulation.
Hafiz, Israt; Berhan, Meklit; Keller, Angela; Haq, Rouseli; Chesnaye, Nicholas; Koporc, Kim; Rahman, Mujibur; Rahman, Shamsur; Mathieu, Els
2015-01-01
Bangladesh's national deworming program targets school-age children (SAC) through bi-annual school-based distributions of mebendazole. Qualitative and quantitative methods were applied to identify challenges related to treatment monitoring within the Munshiganj and Lakshmipur Districts of Bangladesh. Key stakeholder interviews identified several obstacles for successful treatment monitoring within these districts; ambiguity in defining the target population, variances in the methods used for compiling and reporting treatment data, and a general lack of financial and human resources. A treatment coverage cluster survey revealed that bi-annual primary school-based distributions proved to be an effective strategy in reaching school-attending SAC, with rates between 63.0% and 73.3%. However, the WHO target of regular treatment of at least 75% of SAC has yet to be reached. Particularly low coverage was seen amongst non-school attending children (11.4-14.3%), most likely due to the lack of national policy to effectively target this vulnerable group. Survey findings on water and sanitation coverage were impressive with the majority of households and schools having access to latrines (98.6-99.3%) and safe drinking water (98.2-100%). The challenge now for the Bangladesh control program is to achieve the WHO target of regular treatment of at least 75% of SAC at risk, irrespective of school-enrollment status. Copyright © 2013 The Authors. Published by Elsevier B.V. All rights reserved.
Brotherton, Julia M L; Bloem, Paul N
2018-02-01
Persistent oncogenic human papillomavirus (HPV) is the cause of cervical cancer, as well as cancers of the anus, penis, vulva, vagina and oropharynx. There is good evidence that prophylactic HPV vaccines are immunogenic and effective against targeted-type HPV infections and type-specific genital lesions, including high-grade cervical intraepithelial neoplasia (CIN), when administered prior to HPV infection. There is good evidence that HPV vaccines are safe in population usage, with the most frequent adverse event being injection-site reactions. There is evidence to support some cross-protection against non-targeted types occurring following the administration of HPV vaccines. There is limited evidence suggesting that HPV vaccines may be beneficial in preventing future disease in women treated for high-grade CIN. This chapter focuses on the accumulated evidence regarding the global use of the three licensed HPV vaccines including safety, immunogenicity, duration of protection, effectiveness, coverage to date and barriers to higher coverage. Copyright © 2018 Elsevier Ltd. All rights reserved.
Vestibular evoked myogenic potential testing: Payment policy review for clinicians and payers.
Fife, Terry D; Satya-Murti, Saty; Burkard, Robert F; Carey, John P
2018-04-01
A recent American Academy of Neurology Evidence-Based Practice Guideline on vestibular myogenic evoked potential (VEMP) testing has described superior canal dehiscence syndrome (SCDS) and evaluated the merits of VEMP in its diagnosis. SCDS is an uncommon but now well-recognized cause of dizziness and auditory symptoms. This article familiarizes health care providers with this syndrome and the utility and shortcomings of VEMP as a diagnostic test and also explores payment policies for VEMP. In carefully selected patients with documented history compatible with the SCDS, both high-resolution temporal bone CT scan and VEMP are valuable aids for diagnosis. Payers might be unfamiliar with both this syndrome and VEMP testing. It is important to raise awareness of VEMP and its possible indications and the rationale for coverage of VEMP testing. Payers may not be readily receptive to VEMP coverage if this test is used in an undifferentiated manner for all common vestibular and auditory symptoms.
Social hierarchy modulates neural responses of empathy for pain.
Feng, Chunliang; Li, Zhihao; Feng, Xue; Wang, Lili; Tian, Tengxiang; Luo, Yue-Jia
2016-03-01
Recent evidence indicates that empathic responses to others' pain are modulated by various situational and individual factors. However, few studies have examined how empathy and underlying brain functions are modulated by social hierarchies, which permeate human society with an enormous impact on social behavior and cognition. In this study, social hierarchies were established based on incidental skill in a perceptual task in which all participants were mediumly ranked. Afterwards, participants were scanned with functional magnetic resonance imaging while watching inferior-status or superior-status targets receiving painful or non-painful stimulation. The results revealed that painful stimulation applied to inferior-status targets induced higher activations in the anterior insula (AI) and anterior medial cingulate cortex (aMCC), whereas these empathic brain activations were significantly attenuated in response to superior-status targets' pain. Further, this neural empathic bias to inferior-status targets was accompanied by stronger functional couplings of AI with brain regions important in emotional processing (i.e. thalamus) and cognitive control (i.e. middle frontal gyrus). Our findings indicate that emotional sharing with others' pain is shaped by relative positions in a social hierarchy such that underlying empathic neural responses are biased toward inferior-status compared with superior-status individuals. © The Author (2015). Published by Oxford University Press. For Permissions, please email: journals.permissions@oup.com.
Pinchoff, Jessie; Larsen, David A; Renn, Silvia; Pollard, Derek; Fornadel, Christen; Maire, Mark; Sikaala, Chadwick; Sinyangwe, Chomba; Winters, Benjamin; Bridges, Daniel J; Winters, Anna M
2016-01-06
In Zambia and other sub-Saharan African countries affected by ongoing malaria transmission, indoor residual spraying (IRS) for malaria prevention has typically been implemented over large areas, e.g., district-wide, and targeted to peri-urban areas. However, there is a recent shift in some countries, including Zambia, towards the adoption of a more strategic and targeted IRS approach, in coordination with increased emphasis on universal coverage of long-lasting insecticidal nets (LLINs) and effective insecticide resistance management. A true targeted approach would deliver IRS to sub-district areas identified as high-risk, with the goal of maximizing the prevention of malaria cases and deaths. Together with the Government of the Republic of Zambia, a new methodology was developed applying geographic information systems and satellite imagery to support a targeted IRS campaign during the 2014 spray season using health management information system data. This case study focuses on the developed methodology while also highlighting the significant research gaps which must be filled to guide countries on the most effective strategy for IRS targeting in the context of universal LLIN coverage and evolving insecticide resistance.
Campos, Andre N.; Souza, Efren L.; Nakamura, Fabiola G.; Nakamura, Eduardo F.; Rodrigues, Joel J. P. C.
2012-01-01
Target tracking is an important application of wireless sensor networks. The networks' ability to locate and track an object is directed linked to the nodes' ability to locate themselves. Consequently, localization systems are essential for target tracking applications. In addition, sensor networks are often deployed in remote or hostile environments. Therefore, density control algorithms are used to increase network lifetime while maintaining its sensing capabilities. In this work, we analyze the impact of localization algorithms (RPE and DPE) and density control algorithms (GAF, A3 and OGDC) on target tracking applications. We adapt the density control algorithms to address the k-coverage problem. In addition, we analyze the impact of network density, residual integration with density control, and k-coverage on both target tracking accuracy and network lifetime. Our results show that DPE is a better choice for target tracking applications than RPE. Moreover, among the evaluated density control algorithms, OGDC is the best option among the three. Although the choice of the density control algorithm has little impact on the tracking precision, OGDC outperforms GAF and A3 in terms of tracking time. PMID:22969329
Berryessa, Colleen M
In recent years, sensational media reporting focusing on crimes committed by those diagnosed with or thought to have High Functioning Autistic Spectrum Disorders (hfASDs) has caused societal speculation that there is a link between the disorder and violent criminality. No research exists on how and if the judiciary understands and is affected by this coverage. Therefore this study aims to examine how judges perceive and are influenced by media attention surrounding hfASDs and criminality. Semi-structured interviews were conducted with 21 California Superior Court Judges, including questions on media portrayal. Judges perceived general media portrayals of hfASDs in both positive and negative ways. However, almost all judges who had experienced media coverage surrounding hfASDs and criminality identified it as misleading and harmful to public perceptions of the disorder. These findings suggest judges are not exempt from media attention surrounding violence and hfASDs, and they recognize the potential adverse effects of this negative coverage. Although judges' report their opinions are not affected, the results demonstrate that judges are worried that the public and potentially other criminal justice actors are adversely affected and will continue to be moving forward.
Intragumtornchai, Tanin; Bunworasate, Udomsak; Siritanaratkul, Noppadol; Khuhapinant, Archrob; Nawarawong, Weerasak; Norasetthada, Lalita; Lekhakula, Arnuparp; Rujirojindakul, Pairaya; Sirijerachai, Chittima; Chansung, Kanjana; Suwanban, Tawatchai; Chuncharunee, Suporn; Niparuck, Pimjai; Wongkhantee, Somchai; Mongkonsritragoon, Wichean; Numbenjapon, Tontanai
2013-01-01
The impact of health insurance with inequitable rituximab coverage on the survival of patients with diffuse large B-cell lymphoma (DLBCL) has never been reported. We conducted a nationwide multicenter analysis on the outcome of 553 adult patients consecutively diagnosed with DLBCL between July 2003 and June 2006, in whom treatment cost was reimbursed under the Civil Servant Medical Benefit Scheme (CSMBS) (n =201) or the Universal Coverage Scheme (UCS) (n =352). The international prognostic index was comparable between the two payment groups. Rituximab-based therapy was administered in 45.3% and 3.1% of CSMBS and UCS patients, respectively (p <0.001). With a median follow-up of 24.6 months, the 6-year progression-free survival (PFS) was superior for CSMBS patients (34.2 vs. 23.2%, p =0.005). "Not treated with rituximab-based therapy" was the strongest adverse prognostic feature indicating a short PFS (hazard ratio 2.1, p <0.001). It is concluded that lack of access to rituximab is the principal factor accounting for the inferior PFS observed in Thai patients with DLBCL who are treated under the UCS.
Berryessa, Colleen M.
2015-01-01
In recent years, sensational media reporting focusing on crimes committed by those diagnosed with or thought to have High Functioning Autistic Spectrum Disorders (hfASDs) has caused societal speculation that there is a link between the disorder and violent criminality. No research exists on how and if the judiciary understands and is affected by this coverage. Therefore this study aims to examine how judges perceive and are influenced by media attention surrounding hfASDs and criminality. Semi-structured interviews were conducted with 21 California Superior Court Judges, including questions on media portrayal. Judges perceived general media portrayals of hfASDs in both positive and negative ways. However, almost all judges who had experienced media coverage surrounding hfASDs and criminality identified it as misleading and harmful to public perceptions of the disorder. These findings suggest judges are not exempt from media attention surrounding violence and hfASDs, and they recognize the potential adverse effects of this negative coverage. Although judges’ report their opinions are not affected, the results demonstrate that judges are worried that the public and potentially other criminal justice actors are adversely affected and will continue to be moving forward. PMID:25722757
Confetti: A Multiprotease Map of the HeLa Proteome for Comprehensive Proteomics*
Guo, Xiaofeng; Trudgian, David C.; Lemoff, Andrew; Yadavalli, Sivaramakrishna; Mirzaei, Hamid
2014-01-01
Bottom-up proteomics largely relies on tryptic peptides for protein identification and quantification. Tryptic digestion often provides limited coverage of protein sequence because of issues such as peptide length, ionization efficiency, and post-translational modification colocalization. Unfortunately, a region of interest in a protein, for example, because of proximity to an active site or the presence of important post-translational modifications, may not be covered by tryptic peptides. Detection limits, quantification accuracy, and isoform differentiation can also be improved with greater sequence coverage. Selected reaction monitoring (SRM) would also greatly benefit from being able to identify additional targetable sequences. In an attempt to improve protein sequence coverage and to target regions of proteins that do not generate useful tryptic peptides, we deployed a multiprotease strategy on the HeLa proteome. First, we used seven commercially available enzymes in single, double, and triple enzyme combinations. A total of 48 digests were performed. 5223 proteins were detected by analyzing the unfractionated cell lysate digest directly; with 42% mean sequence coverage. Additional strong-anion exchange fractionation of the most complementary digests permitted identification of over 3000 more proteins, with improved mean sequence coverage. We then constructed a web application (https://proteomics.swmed.edu/confetti) that allows the community to examine a target protein or protein isoform in order to discover the enzyme or combination of enzymes that would yield peptides spanning a certain region of interest in the sequence. Finally, we examined the use of nontryptic digests for SRM. From our strong-anion exchange fractionation data, we were able to identify three or more proteotypic SRM candidates within a single digest for 6056 genes. Surprisingly, in 25% of these cases the digest producing the most observable proteotypic peptides was neither trypsin nor Lys-C. SRM analysis of Asp-N versus tryptic peptides for eight proteins determined that Asp-N yielded higher signal in five of eight cases. PMID:24696503
Influenza immunization among Canadian health care personnel: a cross-sectional study
Buchan, Sarah A.; Kwong, Jeffrey C.
2016-01-01
Background: Influenza immunization coverage among Canadian health care personnel remains below national targets. Targeting this group is of particular importance given their elevated risk of influenza infection, role in transmission and influence on patients' immunization status. We examined influenza immunization coverage in health care personnel in Canada, reasons for not being immunized and the impact of "vaccinate-or-mask" influenza prevention policies. Methods: In this national cross-sectional study, we pooled data from the 2007 to 2014 cycles of the Canadian Community Health Survey and restricted it to respondents who reported a health care occupation. Using bootstrapped survey weights, we examined immunization coverage by occupation and by presence of vaccinate-or-mask policies, and reasons for not being immunized. We used modified Poisson regression to estimate the prevalence ratio (PR) of influenza immunization for health care occupations compared with the general working population. Results: For all survey cycles combined, 50% of 18 446 health care personnel reported receiving seasonal influenza immunization during the previous 12 months, although this varied by occupation type (range 4%-72%). Compared with the general working population, family physicians and general practitioners were most likely to be immunized (PR 3.15, 95% confidence interval [CI] 2.76-3.59), whereas chiropractors, midwives and practitioners of natural healing were least likely (PR 0.17, 95% CI 0.10-0.30). Among those who were not immunized, the most frequently cited reason was the belief that influenza immunization is unnecessary. Introduction of vaccinate-or-mask policies was associated with increased influenza immunization among health care personnel. Interpretation: Health care personnel are more likely to be immunized against influenza than the general working population, but coverage remains suboptimal overall, and we observed wide variation by occupation type. More efforts are needed to target specific health care occupations with low immunization coverage. PMID:27730112
Strategies for Coordination of a Serosurvey in Parallel with an Immunization Coverage Survey
Travassos, Mark A.; Beyene, Berhane; Adam, Zenaw; Campbell, James D.; Mulholland, Nigisti; Diarra, Seydou S.; Kassa, Tassew; Oot, Lisa; Sequeira, Jenny; Reymann, Mardi; Blackwelder, William C.; Pasetti, Marcela F.; Sow, Samba O.; Steinglass, Robert; Kebede, Amha; Levine, Myron M.
2015-01-01
A community-based immunization coverage survey is the standard way to estimate effective vaccination delivery to a target population in a region. Accompanying serosurveys can provide objective measures of protective immunity against vaccine-preventable diseases but pose considerable challenges with respect to specimen collection and preservation and community compliance. We performed serosurveys coupled to immunization coverage surveys in three administrative districts (woredas) in rural Ethiopia. Critical to the success of this effort were serosurvey equipment and supplies, team composition, and tight coordination with the coverage survey. Application of these techniques to future studies may foster more widespread use of serosurveys to derive more objective assessments of vaccine-derived seroprotection and monitor and compare the performance of immunization services in different districts of a country. PMID:26055737
Abegunde, Dele; Orobaton, Nosa; Shoretire, Kamil; Ibrahim, Mohammed; Mohammed, Zainab; Abdulazeez, Jumare; Gwamzhi, Ringpon; Ganiyu, Akeem
2015-01-01
Maternal mortality ratio and infant mortality rate are as high as 1,576 per 100,000 live births and 78 per 1,000 live births, respectively, in Nigeria's northwestern region, where Sokoto State is located. Using applicable monitoring indicators for tracking progress in the UN/WHO framework on continuum of maternal, newborn, and child health care, this study evaluated the progress of Sokoto toward achieving the Millennium Development Goals (MDGs) 4 and 5 by December 2015. The changes in outcomes in 2012-2013 associated with maternal and child health interventions were assessed. We used baseline and follow-up lot quality assurance sampling (LQAS) data obtained in 2012 and 2013, respectively. In each of the surveys, data were obtained from 437 households sampled from 19 LQAS locations in each of the 23 local government areas (LGAs). The composite state-level coverage estimates of the respective indicators were aggregated from estimated LGA coverage estimates. None of the nine indicators associated with the continuum of maternal, neonatal, and child care satisfied the recommended 90% coverage target for achieving MDGs 4 and 5. Similarly, the average state coverage estimates were lower than national coverage estimates. Marginal improvements in coverage were obtained in the demand for family planning satisfied, antenatal care visits, postnatal care for mothers, and exclusive breast-feeding. Antibiotic treatment for acute pneumonia increased significantly by 12.8 percentage points. The majority of the LGAs were classifiable as low-performing, high-priority areas for intensified program intervention. Despite the limited time left in the countdown to December 2015, Sokoto State, Nigeria, is not on track to achieving the MDG 90% coverage of indicators tied to the continuum of maternal and child care, to reduce maternal and childhood mortality by a third by 2015. Targeted health system investments at the primary care level remain a priority, for intensive program scale-up to accelerate impact.
Abegunde, Dele; Orobaton, Nosa; Shoretire, Kamil; Ibrahim, Mohammed; Mohammed, Zainab; Abdulazeez, Jumare; Gwamzhi, Ringpon; Ganiyu, Akeem
2015-01-01
Background Maternal mortality ratio and infant mortality rate are as high as 1,576 per 100,000 live births and 78 per 1,000 live births, respectively, in Nigeria's northwestern region, where Sokoto State is located. Using applicable monitoring indicators for tracking progress in the UN/WHO framework on continuum of maternal, newborn, and child health care, this study evaluated the progress of Sokoto toward achieving the Millennium Development Goals (MDGs) 4 and 5 by December 2015. The changes in outcomes in 2012–2013 associated with maternal and child health interventions were assessed. Design We used baseline and follow-up lot quality assurance sampling (LQAS) data obtained in 2012 and 2013, respectively. In each of the surveys, data were obtained from 437 households sampled from 19 LQAS locations in each of the 23 local government areas (LGAs). The composite state-level coverage estimates of the respective indicators were aggregated from estimated LGA coverage estimates. Results None of the nine indicators associated with the continuum of maternal, neonatal, and child care satisfied the recommended 90% coverage target for achieving MDGs 4 and 5. Similarly, the average state coverage estimates were lower than national coverage estimates. Marginal improvements in coverage were obtained in the demand for family planning satisfied, antenatal care visits, postnatal care for mothers, and exclusive breast-feeding. Antibiotic treatment for acute pneumonia increased significantly by 12.8 percentage points. The majority of the LGAs were classifiable as low-performing, high-priority areas for intensified program intervention. Conclusions Despite the limited time left in the countdown to December 2015, Sokoto State, Nigeria, is not on track to achieving the MDG 90% coverage of indicators tied to the continuum of maternal and child care, to reduce maternal and childhood mortality by a third by 2015. Targeted health system investments at the primary care level remain a priority, for intensive program scale-up to accelerate impact. PMID:26455491
Multiplex Degenerate Primer Design for Targeted Whole Genome Amplification of Many Viral Genomes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gardner, Shea N.; Jaing, Crystal J.; Elsheikh, Maher M.
Background . Targeted enrichment improves coverage of highly mutable viruses at low concentration in complex samples. Degenerate primers that anneal to conserved regions can facilitate amplification of divergent, low concentration variants, even when the strain present is unknown. Results . A tool for designing multiplex sets of degenerate sequencing primers to tile overlapping amplicons across multiple whole genomes is described. The new script, run_tiled_primers, is part of the PriMux software. Primers were designed for each segment of South American hemorrhagic fever viruses, tick-borne encephalitis, Henipaviruses, Arenaviruses, Filoviruses, Crimean-Congo hemorrhagic fever virus, Rift Valley fever virus, and Japanese encephalitis virus. Eachmore » group is highly diverse with as little as 5% genome consensus. Primer sets were computationally checked for nontarget cross reactions against the NCBI nucleotide sequence database. Primers for murine hepatitis virus were demonstrated in the lab to specifically amplify selected genes from a laboratory cultured strain that had undergone extensive passage in vitro and in vivo. Conclusions . This software should help researchers design multiplex sets of primers for targeted whole genome enrichment prior to sequencing to obtain better coverage of low titer, divergent viruses. Applications include viral discovery from a complex background and improved sensitivity and coverage of rapidly evolving strains or variants in a gene family.« less
NASA Astrophysics Data System (ADS)
Howard, Ward S.; Law, Nicholas M.; Ziegler, Carl A.; Baranec, Christoph; Riddle, Reed
2018-02-01
Adaptive optics laser guide-star systems perform atmospheric correction of stellar wavefronts in two parts: stellar tip-tilt and high-spatial-order laser correction. The requirement of a sufficiently bright guide star in the field-of-view to correct tip-tilt limits sky coverage. In this paper, we show an improvement to effective seeing without the need for nearby bright stars, enabling full sky coverage by performing only laser-assisted wavefront correction. We used Robo-AO, the first robotic AO system, to comprehensively demonstrate this laser-only correction. We analyze observations from four years of efficient robotic operation covering 15000 targets and 42000 observations, each realizing different seeing conditions. Using an autoguider (or a post-processing software equivalent) and the laser to improve effective seeing independent of the brightness of a target, Robo-AO observations show a 39% ± 19% improvement to effective FWHM, without any tip-tilt correction. We also demonstrate that 50% encircled energy performance without tip-tilt correction remains comparable to diffraction-limited, standard Robo-AO performance. Faint-target science programs primarily limited by 50% encircled energy (e.g., those employing integral field spectrographs placed behind the AO system) may see significant benefits to sky coverage from employing laser-only AO.
Multiplex Degenerate Primer Design for Targeted Whole Genome Amplification of Many Viral Genomes
Gardner, Shea N.; Jaing, Crystal J.; Elsheikh, Maher M.; ...
2014-01-01
Background . Targeted enrichment improves coverage of highly mutable viruses at low concentration in complex samples. Degenerate primers that anneal to conserved regions can facilitate amplification of divergent, low concentration variants, even when the strain present is unknown. Results . A tool for designing multiplex sets of degenerate sequencing primers to tile overlapping amplicons across multiple whole genomes is described. The new script, run_tiled_primers, is part of the PriMux software. Primers were designed for each segment of South American hemorrhagic fever viruses, tick-borne encephalitis, Henipaviruses, Arenaviruses, Filoviruses, Crimean-Congo hemorrhagic fever virus, Rift Valley fever virus, and Japanese encephalitis virus. Eachmore » group is highly diverse with as little as 5% genome consensus. Primer sets were computationally checked for nontarget cross reactions against the NCBI nucleotide sequence database. Primers for murine hepatitis virus were demonstrated in the lab to specifically amplify selected genes from a laboratory cultured strain that had undergone extensive passage in vitro and in vivo. Conclusions . This software should help researchers design multiplex sets of primers for targeted whole genome enrichment prior to sequencing to obtain better coverage of low titer, divergent viruses. Applications include viral discovery from a complex background and improved sensitivity and coverage of rapidly evolving strains or variants in a gene family.« less
Cannon, W.F.; Ottke, Doug
1999-01-01
The data on this CD consist of geographic information system (GIS) coverages and tabular data on the geology of Early Proterozoic and Archean rocks in part of the Early Proterozoic Penokean orogeny. The map emphasizes metasedimentary and metavolcanic rocks that were deposited along the southern margin of the Superior craton and were later deformed during continental collision at about 1850 Ma. The area includes the famous iron ranges of the south shore region of the Lake Superior district. Base maps, both as digital raster graphics (DRG) and digital line graphs (DLG) are also provided for the convenience of users. The map has been compiled from many individual studies, mostly by USGS researchers, completed during the past 50 years, including many detailed (1:24,000 scale) geologic maps. Data was compiled at 1:100,000 scale and preserves most of the details of source materials. This product is a preliminary release of the geologic map data bases during ongoing studies of the geology and metallogeny of the Penokean continental margin. Files are provided in three formats: Federal Spatial Data Transfer format (SDTS), Arc export format (.e00) files, and Arc coverages. All files can be accessed directly from the CD-ROM using either ARC/INFO 7.1.2 or later or Arc View 3.0 or later software. ESRI's Arc Explorer, a free GIS data viewer available at the web site: http://www.esri.com/software/arcexplorer/index.html also provides display and querying capability for these files.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sugar, E Neubauer; Buzurovic, I; O’Farrell, D
2015-06-15
Purpose: To compare the dosimetry of a standard rectilinear and an adaptive technique used in I125 prostate seed implants. Methods: To achieve favorable dosimetry in prostate implants we used adaptive needle updates to match actual positions in real-time. The seed locations were optimized based on actual needle locations. The seeds were delivered automatically with a robotic device seedSelectron™ (Elekta Brachytherapy). In this study, we evaluated the former approach against the standard rectilinear technique in which the needles have a parallel distribution. The treatment plans for 10 patients were analyzed. For comparison, the actual treatment plans were revised so each needlemore » was repositioned to its original parallel location through the template. The analysis was performed by comparing the target coverage and dose to the organs at risk. The comparison was done using the following planning goals: the target D90> 90%, V100% > 90%, V50% <70% and V200% <30%; the urethra V125% < 1cm3 and V150%= 0cm3; and the Rectum V100%<1cm3 and V69% < 8cm3. The prescription dose to the target was 145Gy. Results: The average target volume and number of seeds were 44.39cm3(SD=11.14) and 74(SD=12), respectively. The D90 for adaptive and rectilinear plans was 159.9Gy(SD=2.99) and 155.53Gy(SD=4.04) resulting in a 2.74% difference for the average target coverage. A similar difference (1.75%) was noticed in the target V100[%]. No significant difference was noticed in the dose to the urethra and rectum. All planning goals were met with both the adaptive and rectilinear approach for each plan. Conclusion: The study reveals enhanced coverage of the target when using the adaptive needle adjustments as compared to the rectilinear approach for the analyzed cases. However, the differences in dosimetry did not translate to meaningful clinical outcomes.« less
SU-E-J-188: Theoretical Estimation of Margin Necessary for Markerless Motion Tracking
DOE Office of Scientific and Technical Information (OSTI.GOV)
Patel, R; Block, A; Harkenrider, M
2015-06-15
Purpose: To estimate the margin necessary to adequately cover the target using markerless motion tracking (MMT) of lung lesions given the uncertainty in tracking and the size of the target. Methods: Simulations were developed in Matlab to determine the effect of tumor size and tracking uncertainty on the margin necessary to achieve adequate coverage of the target. For simplicity, the lung tumor was approximated by a circle on a 2D radiograph. The tumor was varied in size from a diameter of 0.1 − 30 mm in increments of 0.1 mm. From our previous studies using dual energy markerless motion tracking,more » we estimated tracking uncertainties in x and y to have a standard deviation of 2 mm. A Gaussian was used to simulate the deviation between the tracked location and true target location. For each size tumor, 100,000 deviations were randomly generated, the margin necessary to achieve at least 95% coverage 95% of the time was recorded. Additional simulations were run for varying uncertainties to demonstrate the effect of the tracking accuracy on the margin size. Results: The simulations showed an inverse relationship between tumor size and margin necessary to achieve 95% coverage 95% of the time using the MMT technique. The margin decreased exponentially with target size. An increase in tracking accuracy expectedly showed a decrease in margin size as well. Conclusion: In our clinic a 5 mm expansion of the internal target volume (ITV) is used to define the planning target volume (PTV). These simulations show that for tracking accuracies in x and y better than 2 mm, the margin required is less than 5 mm. This simple simulation can provide physicians with a guideline estimation for the margin necessary for use of MMT clinically based on the accuracy of their tracking and the size of the tumor.« less
Sturrock, H.; Hsiang, M.; Roberts, K.; Kleinschmidt, I.; Nghipumbwa, M.; Uusiku, P.; Smith, J.; Bennet, A.; Kizito, W.; Takarinda, K.; Ade, S.; Gosling, R.
2018-01-01
Setting: A comparison of routine Namibia National Malaria Programme data (reported) vs. household survey data (administrative) on indoor residual spraying (IRS) in western Zambezi region, Namibia, for the 2014–2015 malaria season. Objectives: To determine 1) IRS coverage (administrative and reported), 2) its effect on malaria incidence, and 3) reasons for non-uptake of IRS in western Zambezi region, Namibia, for the 2014–2015 malaria season. Design: This was a descriptive study. Results: IRS coverage in western Zambezi region was low, ranging from 42.3% to 52.2% for administrative coverage vs. 45.9–66.7% for reported coverage. There was no significant correlation between IRS coverage and malaria incidence for this region (r = −0.45, P = 0.22). The main reasons for households not being sprayed were that residents were not at home during spraying times or that spray operators did not visit the households. Conclusions: IRS coverage in western Zambezi region, Namibia, was low during the 2014–2015 malaria season because of poor community engagement and awareness of times for spray operations within communities. Higher IRS coverage could be achieved through improved community engagement. Better targeting of the highest risk areas by the use of malaria surveillance will be required to mitigate malaria transmission. PMID:29713594
NSW Annual Immunisation Coverage Report, 2009.
Hull, Brynley; Dey, Aditi; Mahajan, Deepika; Campbell-Lloyd, Sue; Menzies, Robert I; McIntyre, Peter B
2010-01-01
This is the first in a series of annual immunisation coverage reports that document trends in NSW for a range of standard measures derived from Australian Childhood Immunisation Register data, including overall coverage at standard age milestones and for individual vaccines. This report includes data up to and including 2009. Data from the Australian Childhood Immunisation Register, the NSW Health Survey and the NSW School Immunisation Program were used to calculate various measures of population coverage relating to childhood vaccines, adult influenza and pneumococcal vaccines and adolescent vaccination, respectively. Immunise Australia Program targets have been reached for children at 12 and 24 months of age but not for children at 5 years of age. Delayed receipt of vaccines is an issue for vaccines recommended for Aboriginal children. Pneumococcal vaccination in the elderly has been steadily rising, although it has remained lower than the influenza coverage estimates. For adolescents, there is better coverage for the first and second doses of human papillomavirus vaccine and the dose of dTpa than for varicella. This comprehensive analysis provides important baseline data for NSW against which future reports can be compared to monitor progress in improving immunisation coverage. Immunisation at the earliest appropriate age should be a public health goal for countries such as Australia where high levels of vaccine coverage at milestone ages have been achieved.
Oswald, William E.; Stewart, Aisha E. P.; Flanders, W. Dana; Kramer, Michael R.; Endeshaw, Tekola; Zerihun, Mulat; Melaku, Birhanu; Sata, Eshetu; Gessesse, Demelash; Teferi, Tesfaye; Tadesse, Zerihun; Guadie, Birhan; King, Jonathan D.; Emerson, Paul M.; Callahan, Elizabeth K.; Moe, Christine L.; Clasen, Thomas F.
2016-01-01
This study developed and validated a model for predicting the probability that communities in Amhara Region, Ethiopia, have low sanitation coverage, based on environmental and sociodemographic conditions. Community sanitation coverage was measured between 2011 and 2014 through trachoma control program evaluation surveys. Information on environmental and sociodemographic conditions was obtained from available data sources and linked with community data using a geographic information system. Logistic regression was used to identify predictors of low community sanitation coverage (< 20% versus ≥ 20%). The selected model was geographically and temporally validated. Model-predicted probabilities of low community sanitation coverage were mapped. Among 1,502 communities, 344 (22.90%) had coverage below 20%. The selected model included measures for high topsoil gravel content, an indicator for low-lying land, population density, altitude, and rainfall and had reasonable predictive discrimination (area under the curve = 0.75, 95% confidence interval = 0.72, 0.78). Measures of soil stability were strongly associated with low community sanitation coverage, controlling for community wealth, and other factors. A model using available environmental and sociodemographic data predicted low community sanitation coverage for areas across Amhara Region with fair discrimination. This approach could assist sanitation programs and trachoma control programs, scaling up or in hyperendemic areas, to target vulnerable areas with additional activities or alternate technologies. PMID:27430547
Mumbengegwi, D R; Sturrock, H; Hsiang, M; Roberts, K; Kleinschmidt, I; Nghipumbwa, M; Uusiku, P; Smith, J; Bennet, A; Kizito, W; Takarinda, K; Ade, S; Gosling, R
2018-04-25
Setting: A comparison of routine Namibia National Malaria Programme data (reported) vs. household survey data (administrative) on indoor residual spraying (IRS) in western Zambezi region, Namibia, for the 2014-2015 malaria season. Objectives: To determine 1) IRS coverage (administrative and reported), 2) its effect on malaria incidence, and 3) reasons for non-uptake of IRS in western Zambezi region, Namibia, for the 2014-2015 malaria season. Design: This was a descriptive study. Results: IRS coverage in western Zambezi region was low, ranging from 42.3% to 52.2% for administrative coverage vs. 45.9-66.7% for reported coverage. There was no significant correlation between IRS coverage and malaria incidence for this region ( r = -0.45, P = 0.22). The main reasons for households not being sprayed were that residents were not at home during spraying times or that spray operators did not visit the households. Conclusions: IRS coverage in western Zambezi region, Namibia, was low during the 2014-2015 malaria season because of poor community engagement and awareness of times for spray operations within communities. Higher IRS coverage could be achieved through improved community engagement. Better targeting of the highest risk areas by the use of malaria surveillance will be required to mitigate malaria transmission.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Galavis, P; Barbee, D; Jozsef, G
2016-06-15
Purpose: Prone accelerated partial breast irradiation (APBI) results in dose reduction to the heart and lung. Flattening filter free beams (FFF) reduce out of field dose due to the reduced scatter from the removal of the flattening filter and reduce the buildup region. The aim of this work is to evaluate the dosimetric advantages of FFF beams to prone APBI target coverage and reduction in dose to organs at risk. Methods: Fifteen clinical prone APBI cases using flattened photon beams were retrospectively re-planned in Eclipse-TPS using FFF beams. FFF plans were designed to provide equivalent target coverage with similar hotspotsmore » using the same field arrangements, resulting in comparable target DVHs. Both plans were transferred to a prone breast phantom and delivered on Varian-Edge-Linac. GafChromic-film was placed in the coronal plane of the phantom, partially overlapping the treatment field and extending into OARs to compare dose profiles from both plans. Results: FFF plans were comparable to the clinical plans with maximum doses of (108.3±2.3)% and (109.2±2.4)% and mean doses of (104.5±1.0)% and (104.6±1.2)%, respectively. Similar mean dose doses to the heart and contralateral lungs were observed from both plans, whereas the mean dose to the contra-lateral breast was (2.79±1.18) cGy and (2.86±1.40) cGy for FFF and clinical plans respectively. However for both plans the error between calculated and measured doses at 4 cm from the field edge was 10%. Conclusion: The results showed that FFF beams in prone APBI provide dosimetrically equivalent target coverage and improved coverage in superficial target due to softer energy spectra. Film analysis showed that the TPS underestimates dose outside field edges for both cases. The FFF measured plans showed less dose outside the beam that might reduce the probability of secondary cancers in the contralateral breast.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pokhrel, D; Sood, S; Badkul, R
2015-06-15
Purpose: To investigate the feasibility of using RapidArc (RA) treatment planning to reduce irradiation volume of normal lung and other organs at risk (OARs) in the treatment of inoperable non-small-cell lung cancer (NSCLC) patients. Methods: A retrospective treatment planning and delivery study was performed to compare target coverage and the volumes of the normal lung, spinal cord, heart and esophagus on 4D-CT scan above their dose tolerances delivered by RA vs. IMRT for ten inoperable NSCLC patients (Stage I-IIIB). RA plans consisted of either one-full or two-partial co-planar arcs used to treat 95% of the planning target volume (PTV) withmore » 6MV beam to a prescription of 66Gy in 33 fractions. IMRT plans were generated using 5–7 co-planar fields with 6MV beam. PTV coverage, dose-volume histograms, homogeneity/conformity indices (CI), total number of monitor units(MUs), beam-on time and delivery accuracy were compared between the two treatment plans. Results: Similar target coverage was obtained between the two techniques. RA (CI=1.02) provided more conformal plans without loss of homogeneity compared to IMRT plans (CI=1.12). Compared to IMRT, RA achieved a significant median dose reduction in V10 (3%), V20 (8%), and mean lung dose (3%) on average, respectively. On average, V5 was comparable between the two treatment plans. RA reduced mean esophagus (6%), mean heart (18%), and maximum spinal cord dose (7%), on average, respectively. Total number of MUs and beam-on time were each reduced almost by a factor of 2 when compared to IMRT-patient comfort, reduced intra-fraction-motion and leakage dose. The average IMRT and RA QA pass rate was about 98% for both types of plans for 3%/3mm criterion. Conclusion: Compared to IMRT plans, RA provided not only comparable target coverage, but also improved conformity, treatment time, and significant reduction in irradiation of OARs. This may potentially allow for target dose escalation without increase in normal tissue toxicity.« less
Giorgi Rossi, Paolo; Carrozzi, Giuliano; Federici, Antonio; Mancuso, Pamela; Sampaolo, Letizia; Zappa, Marco
2018-03-01
Objectives In Italy, regional governments organize cervical, breast and colorectal cancer screening programmes, but there are difficulties in regularly inviting all the target populations and participation remains low. We analysed the determinants associated with invitation coverage of and participation in these programmes. Methods We used data on screening programmes from annual Ministry of Health surveys, 1999-2012 for cervical, 1999-2011 for breast and 2005-2011 for colorectal cancer. For recent years, we linked these data to the results of the national routine survey on preventive behaviours to evaluate the effect of spontaneous screening at Province level. Invitation and participation relative risk were calculated using Generalized Linear Models. Results There is a strong decreasing trend in invitation coverage and participation in screening programmes from North to South Italy. In metropolitan areas, both invitation coverage (rate ratio 0.35-0.96) and participation (rate ratio 0.63-0.88) are lower. An inverse association exists between spontaneous screening and both screening invitation coverage (1-3% decrease in invitation coverage per 1% spontaneous coverage increase) and participation (2% decrease in participation per 1% spontaneous coverage increase) for the three programmes. High recall rate has a negative effect on invitation coverage in the next round for breast cancer (1% decrease in invitation per 1% recall increase). Conclusions Organizational and cultural changes are needed to better implement cancer screening in southern Italy.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jin, L; Fan, J; Eldib, A
Purpose: Treating nose skin with an electron beam is of a substantial challenge due to uneven nose surfaces and tissue heterogeneity, and consequently could have a great uncertainty of dose accuracy on the target. This work explored the method using Monte Carlo (MC)-based energy and intensity modulated electron radiotherapy (MERT), which would be delivered with a photon MLC in a standard medical linac (Artiste). Methods: The traditional treatment on the nose skin involves the usage of a bolus, often with a single energy electron beam. This work avoided using the bolus, and utilized mixed energies of electron beams. An in-housemore » developed Monte Carlo (MC)-based dose calculation/optimization planning system was employed for treatment planning. Phase space data (6, 9, 12 and 15 MeV) were used as an input source for MC dose calculations for the linac. To reduce the scatter-caused penumbra, a short SSD (61 cm) was used. A clinical case of the nose skin, which was previously treated with a single 9 MeV electron beam, was replanned with the MERT method. The resultant dose distributions were compared with the plan previously clinically used. The dose volume histogram of the MERT plan is calculated to examine the coverage of the planning target volume (PTV) and critical structure doses. Results: The target coverage and conformality in the MERT plan are improved as compared to the conventional plan. The MERT can provide more sufficient target coverage and less normal tissue dose underneath the nose skin. Conclusion: Compared to the conventional treatment technique, using MERT for the nose skin treatment has shown the dosimetric advantages in the PTV coverage and conformality. In addition, this technique eliminates the necessity of the cutout and bolus, which makes the treatment more efficient and accurate.« less
SU-E-J-159: Analysis of Total Imaging Uncertainty in Respiratory-Gated Radiotherapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Suzuki, J; Okuda, T; Sakaino, S
Purpose: In respiratory-gated radiotherapy, the gating phase during treatment delivery needs to coincide with the corresponding phase determined during the treatment plan. However, because radiotherapy is performed based on the image obtained for the treatment plan, the time delay, motion artifact, volume effect, and resolution in the images are uncertain. Thus, imaging uncertainty is the most basic factor that affects the localization accuracy. Therefore, these uncertainties should be analyzed. This study aims to analyze the total imaging uncertainty in respiratory-gated radiotherapy. Methods: Two factors of imaging uncertainties related to respiratory-gated radiotherapy were analyzed. First, CT image was used to determinemore » the target volume and 4D treatment planning for the Varian Realtime Position Management (RPM) system. Second, an X-ray image was acquired for image-guided radiotherapy (IGRT) for the BrainLAB ExacTrac system. These factors were measured using a respiratory gating phantom. The conditions applied during phantom operation were as follows: respiratory wave form, sine curve; respiratory cycle, 4 s; phantom target motion amplitude, 10, 20, and 29 mm (which is maximum phantom longitudinal motion). The target and cylindrical marker implanted in the phantom coverage of the CT images was measured and compared with the theoretically calculated coverage from the phantom motion. The theoretical position of the cylindrical marker implanted in the phantom was compared with that acquired from the X-ray image. The total imaging uncertainty was analyzed from these two factors. Results: In the CT image, the uncertainty between the target and cylindrical marker’s actual coverage and the coverage of CT images was 1.19 mm and 2.50mm, respectively. In the Xray image, the uncertainty was 0.39 mm. The total imaging uncertainty from the two factors was 1.62mm. Conclusion: The total imaging uncertainty in respiratory-gated radiotherapy was clinically acceptable. However, an internal margin should be added to account for the total imaging uncertainty.« less
Abuya, Timothy O.; Fegan, Greg; Amin, Abdinasir A.; Akhwale, Willis S.; Noor, Abdisalan M.; Snow, Robert W.; Marsh, Vicki
2010-01-01
Background Private medicine retailers (PMRs) are key partners in the home management of fevers in many settings. Current evidence on effectiveness for PMR interventions at scale is limited. This study presents evaluation findings of two different programs implemented at moderate scale targeting PMRs for malaria control in the Kisii and Kwale districts of Kenya. Key components of this evaluation were measurement of program performance, including coverage, PMR knowledge, practices, and utilization based on spatial analysis. Methodology/Principal Findings The study utilized mixed quantitative methods including retail audits and surrogate client surveys based on post-intervention cross-sectional surveys in intervention and control areas and mapping of intervention outlets. There was a large and significant impact on PMR knowledge and practices of the program in Kisii, with 60.5% of trained PMRs selling amodiaquine medicines in adequate doses compared to 2.8% of untrained ones (OR; 53.5: 95% CI 6.7, 428.3), a program coverage of 69.7% targeted outlets, and a potential utilization of about 30,000 children under five. The evaluation in Kwale also indicates a significant impact with 18.8% and 2.3% intervention and control PMRs selling amodiaquine with correct advice, respectively (OR; 9.4: 95% CI 1.1, 83.7), a program coverage of 25.3% targeted outlets, and a potential utilization of about 48,000 children under five. A provisional benchmark of 7.5 km was a reasonable threshold distance for households to access PMR services. Conclusions/Significance This evaluation show that PMR interventions operationalized in the district level settings are likely to impact PMR knowledge and practices and lead to increased coverage of appropriate treatment to target populations. There is value of evaluating different dimensions of public health programs, including quality, spatial access, and implementation practice. This approach strengthens the potential contribution of pragmatic study designs to evaluating public health programs in the real world. PMID:20126620
DOE Office of Scientific and Technical Information (OSTI.GOV)
Laoui, S; Dietrich, S; Sehgal, V
2016-06-15
Purpose: Radiation dose delivery for endometrial cancer using HDR techniques is limited by dose to bladder and rectum. A dosimetric study was performed using Varian Capri vaginal brachytherapy applicator to determine the optimal channel configuration which minimizes dose to bladder and rectum, while providing good target coverage. Methods: A total of 17 patients, 63 plans clinically delivered, and 252 simulated plans using Varian BrachyVision planning system were generated to investigate optimal channel configuration which results in minimum dose to bladder and rectum while providing adequate target coverage. The Capri applicator consists of 13 lumens arranged in two concentric rings, onemore » central lumen and six lumens per ring. Manual dose shaping is invariably required to lower the dose to critical organs. Three-dimensional plans were simulated for 4 channel arrangements, all 13 channels, channel 12 o’clock (close to bladder) and 6 o’clock (close to rectum) deactivated, central channel deactivated, and central channel in addition to 12 o’clock and 6 o’clock deactivated. A relationship between V100, the volume that receives the prescribed dose, and the amount of curie-seconds required to deliver it, was established. Results: Using all 13 channels results in maximum dose to bladder and rectum. Deactivating central channel in addition to 12 o’clock and 6 o’clock resulted in minimizing bladder and rectum doses but compromised target coverage. The relationship between V100, the volume that receives the prescribed dose, and the curie seconds was found to be linear. Conclusion: Deactivating channels 12 o’clock and 6 o’clock was shown to be the optimal configuration leading to minimum dose to bladder and rectum without compromising target coverage. The linear relationship between V100 and the curie- seconds can be used as a verification parameter.« less
Zhang, Xiaodong; Zhao, Kuai-Le; Guerrero, Thomas M.; McGuire, Sean E.; Yaremko, Brian; Komaki, Ritsuko; Cox, James D.; Hui, Zhouguang; Li, Yupeng; Newhauser, Wayne D.; Mohan, Radhe; Liao, Zhongxing
2008-01-01
Purpose To compare three-dimensional (3D) and 4D computed tomography (CT)– based treatment plans for proton therapy or intensity-modulated radiation therapy (IMRT) for esophageal cancer in terms of doses to the lung, heart, and spinal cord and variations in target coverage and normal tissue sparing. Materials and Methods IMRT and proton plans for 15 patients with distal esophageal cancer were designed from the 3D average CT scans and then recalculated on 10 4D CT data sets. Dosimetric data were compared for tumor coverage and normal tissue sparing. Results Compared with IMRT, median lung volumes exposed to 5,10, and 20 Gy and mean lung dose were reduced by 35.6%, 20.5%,5.8%, and 5.1 Gy for a two-beam proton plan and by 17.4%,8.4%,5%, and 2.9 Gy for a three-beam proton plan. The greater lung sparing in the two-beam proton plan was achieved at the expense of less conformity to the target (conformity index CI=1.99) and greater irradiation of the heart (heart-V40=41.8%) compared with the IMRT plan(CI=1.55, heart-V40=35.7%) or the three-beam proton plan (CI=1.46, heart-V40=27.7%). Target coverage differed by more than 2% between the 3D and 4D plans for patients with substantial diaphragm motion in the three-beam proton and IMRT plans. The difference in spinal cord maximum dose between 3D and 4D plans could exceed 5 Gy for the proton plans partly owing to variations in stomach gas-filling. Conclusions Proton therapy provided significantly better sparing of lung than did IMRT. Diaphragm motion and stomach gas-filling must be considered in evaluating target coverage and cord doses. PMID:18722278
Zhang, Xiaodong; Zhao, Kuai-le; Guerrero, Thomas M; McGuire, Sean E; Yaremko, Brian; Komaki, Ritsuko; Cox, James D; Hui, Zhouguang; Li, Yupeng; Newhauser, Wayne D; Mohan, Radhe; Liao, Zhongxing
2008-09-01
To compare three-dimensional (3D) and four-dimensional (4D) computed tomography (CT)-based treatment plans for proton therapy or intensity-modulated radiation therapy (IMRT) for esophageal cancer in terms of doses to the lung, heart, and spinal cord and variations in target coverage and normal tissue sparing. The IMRT and proton plans for 15 patients with distal esophageal cancer were designed from the 3D average CT scans and then recalculated on 10 4D CT data sets. Dosimetric data were compared for tumor coverage and normal tissue sparing. Compared with IMRT, median lung volumes exposed to 5, 10, and 20 Gy and mean lung dose were reduced by 35.6%, 20.5%, 5.8%, and 5.1 Gy for a two-beam proton plan and by 17.4%, 8.4%, 5%, and 2.9 Gy for a three-beam proton plan. The greater lung sparing in the two-beam proton plan was achieved at the expense of less conformity to the target (conformity index [CI], 1.99) and greater irradiation of the heart (heart-V40, 41.8%) compared with the IMRT plan(CI, 1.55, heart-V40, 35.7%) or the three-beam proton plan (CI, 1.46, heart-V40, 27.7%). Target coverage differed by more than 2% between the 3D and 4D plans for patients with substantial diaphragm motion in the three-beam proton and IMRT plans. The difference in spinal cord maximum dose between 3D and 4D plans could exceed 5 Gy for the proton plans partly owing to variations in stomach gas filling. Proton therapy provided significantly better sparing of lung than did IMRT. Diaphragm motion and stomach gas-filling must be considered in evaluating target coverage and cord doses.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Calvo, Juan Francisco, E-mail: jfcdrr@gmail.com; San José, Sol; Garrido, LLuís
2013-10-01
To introduce an approach for online adaptive replanning (i.e., dose-guided radiosurgery) in frameless stereotactic radiosurgery, when a 6-dimensional (6D) robotic couch is not available in the linear accelerator (linac). Cranial radiosurgical treatments are planned in our department using intensity-modulated technique. Patients are immobilized using thermoplastic mask. A cone-beam computed tomography (CBCT) scan is acquired after the initial laser-based patient setup (CBCT{sub setup}). The online adaptive replanning procedure we propose consists of a 6D registration-based mapping of the reference plan onto actual CBCT{sub setup}, followed by a reoptimization of the beam fluences (“6D plan”) to achieve similar dosage as originally wasmore » intended, while the patient is lying in the linac couch and the original beam arrangement is kept. The goodness of the online adaptive method proposed was retrospectively analyzed for 16 patients with 35 targets treated with CBCT-based frameless intensity modulated technique. Simulation of reference plan onto actual CBCT{sub setup}, according to the 4 degrees of freedom, supported by linac couch was also generated for each case (4D plan). Target coverage (D99%) and conformity index values of 6D and 4D plans were compared with the corresponding values of the reference plans. Although the 4D-based approach does not always assure the target coverage (D99% between 72% and 103%), the proposed online adaptive method gave a perfect coverage in all cases analyzed as well as a similar conformity index value as was planned. Dose-guided radiosurgery approach is effective to assure the dose coverage and conformity of an intracranial target volume, avoiding resetting the patient inside the mask in a “trial and error” way so as to remove the pitch and roll errors when a robotic table is not available.« less
Exploring What's Missing: What Do Target Absent Trials Reveal about Autism Search Superiority?
ERIC Educational Resources Information Center
Keehn, Brandon; Joseph, Robert M.
2016-01-01
We used eye-tracking to investigate the roles of enhanced discrimination and peripheral selection in superior visual search in autism spectrum disorder (ASD). Children with ASD were faster at visual search than their typically developing peers. However, group differences in performance and eye-movements did not vary with the level of difficulty of…
State of equity: childhood immunization in the World Health Organization African Region.
Casey, Rebecca Mary; Hampton, Lee McCalla; Anya, Blanche-Philomene Melanga; Gacic-Dobo, Marta; Diallo, Mamadou Saliou; Wallace, Aaron Stuart
2017-01-01
In 2010, the Global Vaccine Action Plan called on all countries to reach and sustain 90% national coverage and 80% coverage in all districts for the third dose of diphtheria-tetanus-pertussis vaccine (DTP3) by 2015 and for all vaccines in national immunization schedules by 2020. The aims of this study are to analyze recent trends in national vaccination coverage in the World Health Organization African Region andto assess how these trends differ by country income category. We compared national vaccination coverage estimates for DTP3 and the first dose of measles-containing vaccine (MCV) obtained from the World Health Organization (WHO)/United Nations Children's Fund (UNICEF) joint estimates of national immunization coverage for all African Region countries. Using United Nations (UN) population estimates of surviving infants and country income category for the corresponding year, we calculated population-weighted average vaccination coverage by country income category (i.e., low, lower middle, and upper middle-income) for the years 2000, 2005, 2010 and 2015. DTP3 coverage in the African Region increased from 52% in 2000 to 76% in 2015,and MCV1 coverage increased from 53% to 74% during the same period, but with considerable differences among countries. Thirty-six African Region countries were low income in 2000 with an average DTP3 coverage of 50% while 26 were low income in 2015 with an average coverage of 80%. Five countries were lower middle-income in 2000 with an average DTP3 coverage of 84% while 12 were lower middle-income in 2015 with an average coverage of 69%. Five countries were upper middle-income in 2000 with an average DTP3 coverage of 73% and eight were upper middle-income in 2015 with an average coverage of 76%. Disparities in vaccination coverage by country persist in the African Region, with countries that were lower middle-income having the lowest coverage on average in 2015. Monitoring and addressing these disparities is essential for meeting global immunization targets.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rafti, Matías; Imbihl, Ronald, E-mail: imbihl@pci.uni-hannover.de
2014-12-07
By means of photoemission electron microscopy as spatially resolving method, the effect of high coverages of coadsorbed potassium (0.16 ≤ θ{sub K} ≤ 0.21) on the dynamical behavior of the H{sub 2} + O{sub 2} reaction over a Rh(110) surface was investigated. We observe that the originally bistable system is transformed into an excitable system as evidenced by the formation of target patterns and spiral waves. At K coverages close to saturation (θ{sub K} ≈ 0.21) mass transport of potassium with pulses is seen.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kranen, Simon van; Hamming-Vrieze, Olga; Wolf, Annelisa
Purpose: We set out to investigate loss of target coverage from anatomy changes in head and neck cancer patients as a function of applied safety margins and to verify a cone beam computed tomography (CBCT)–based adaptive strategy with an average patient anatomy to overcome possible target underdosage. Methods and Materials: For 19 oropharyngeal cancer patients, volumetric modulated arc therapy treatment plans (2 arcs; simultaneous integrated boost, 70 and 54.25 Gy; 35 fractions) were automatically optimized with uniform clinical target volume (CTV)–to–planning target volume margins of 5, 3, and 0 mm. We applied b-spline CBCT–to–computed tomography (CT) deformable registration to allow recalculation ofmore » the dose on modified CT scans (planning CT deformed to daily CBCT following online positioning) and dose accumulation in the planning CT scan. Patients with deviations in primary or elective CTV coverage >2 Gy were identified as candidates for adaptive replanning. For these patients, a single adaptive intervention was simulated with an average anatomy from the first 10 fractions. Results: Margin reduction from 5 mm to 3 mm to 0 mm generally led to an organ-at-risk (OAR) mean dose (D{sub mean}) sparing of approximately 1 Gy/mm. CTV shrinkage was mainly seen in the elective volumes (up to 10%), likely related to weight loss. Despite online repositioning, substantial systematic errors were present (>3 mm) in lymph node CTV, the parotid glands, and the larynx. Nevertheless, the average increase in OAR dose was small: maximum of 1.2 Gy (parotid glands, D{sub mean}) for all applied margins. Loss of CTV coverage >2 Gy was found in 1, 3, and 7 of 73 CTVs, respectively. Adaptive intervention in 0-mm plans substantially improved coverage: in 5 of 7 CTVs (in 6 patients) to <2 Gy of initially planned. Conclusions: Volumetric modulated arc therapy head and neck cancer treatment plans with 5-mm margins are robust for anatomy changes and show a modest increase in OAR dose. Margin reduction improves OAR sparing with approximately 1 Gy/mm at the expense of target coverage in a subgroup of patients. Patients at risk of CTV underdosage >2 Gy in 0-mm plans may be identified early in treatment using dose accumulation. A single intervention with an average anatomy derived from CBCT effectively mitigates discrepancies.« less
Massa, K; Olsen, A; Sheshe, A; Ntakamulenga, R; Ndawi, B; Magnussen, P
2009-11-01
Control programmes generally use a school-based strategy of mass drug administration to reduce morbidity of schistosomiasis and soil-transmitted helminthiasis (STH) in school-aged populations. The success of school-based programmes depends on treatment coverage. The community-directed treatment (ComDT) approach has been implemented in the control of onchocerciasis and lymphatic filariasis in Africa and improves treatment coverage. This study compared the treatment coverage between the ComDT approach and the school-based treatment approach, where non-enrolled school-aged children were invited for treatment, in the control of schistosomiasis and STH among enrolled and non-enrolled school-aged children. Coverage during the first treatment round among enrolled children was similar for the two approaches (ComDT: 80.3% versus school: 82.1%, P=0.072). However, for the non-enrolled children the ComDT approach achieved a significantly higher coverage than the school-based approach (80.0 versus 59.2%, P<0.001). Similar treatment coverage levels were attained at the second treatment round. Again, equal levels of treatment coverage were found between the two approaches for the enrolled school-aged children, while the ComDT approach achieved a significantly higher coverage in the non-enrolled children. The results of this study showed that the ComDT approach can obtain significantly higher treatment coverage among the non-enrolled school-aged children compared to the school-based treatment approach for the control of schistosomiasis and STH.
Feasibility of Adaptive MR-guided Stereotactic Body Radiotherapy (SBRT) of Lung Tumors
Simpson, Garrett N; Llorente, Ricardo; Samuels, Michael A; Dogan, Nesrin
2018-01-01
Online adaptive radiotherapy (ART) with frequent imaging has the potential to improve dosimetric accuracy by accounting for anatomical and functional changes during the course of radiotherapy. Presented are three interesting cases that provide an assessment of online adaptive magnetic resonance-guided radiotherapy (MRgRT) for lung stereotactic body radiotherapy (SBRT). The study includes three lung SBRT cases, treated on an MRgRT system where MR images were acquired for planning and prior to each treatment fraction. Prescription dose ranged from 48 to 50 Gy in four to five fractions, normalized to where 95% of the planning target volume (PTV) was covered by 100% of the prescription dose. The process begins with the gross tumor volume (GTV), PTV, spinal cord, lungs, heart, and esophagus being delineated on the planning MRI. The treatment plan was then generated using a step-and-shoot intensity modulated radiotherapy (IMRT) technique, which utilized a Monte Carlo dose calculation. Next, the target and organs at risk (OAR) contours from the planning MRI were deformably propagated to the daily setup MRIs. These deformed contours were reviewed and modified by the physician. To determine the efficacy of ART, two different strategies were explored: 1) Calculating the plan created for the planning MR on each fraction setup MR dataset (Non-Adapt) and 2) creating a new optimized IMRT plan on the fraction setup MR dataset (FxAdapt). The treatment plans from both strategies were compared using the clinical dose-volume constraints. PTV coverage constraints were not met for 33% Non-Adapt fractions; all FxAdapt fractions met this constraint. Eighty-eight percent of all OAR constraints studied were better on FxAdapt plans, while 12% of OAR constraints were superior on Non-Adapt fractions. The OAR that garnered the largest benefit would be the uninvolved lung, with superior sparing in 92% of the FxAdapt studied. Similar, but less pronounced, benefits from adaptive planning were experienced for the spinal cord, chest wall, and esophagus. Online adaptive MR-guided lung SBRT can provide better target conformality and homogeneity and OAR sparing compared with non-adaptive SBRT in selected cases. Conversely, if the PTV isn’t adjacent to multiple OARs, then the benefit from ART may be limited. Further studies, which incorporate a larger cohort of patients with uniform prescriptions, are needed to thoroughly evaluate the benefits of daily online ART during MRgRT. PMID:29872603
Whitaker, May
2016-01-01
Purpose Inverse planning simulated annealing (IPSA) optimized brachytherapy treatment plans are characterized with large isolated dwell times at the first or last dwell position of each catheter. The potential of catheter shifts relative to the target and organs at risk in these plans may lead to a more significant change in delivered dose to the volumes of interest relative to plans with more uniform dwell times. Material and methods This study aims to determine if the Nucletron Oncentra dwell time deviation constraint (DTDC) parameter can be optimized to improve the robustness of high-dose-rate (HDR) prostate brachytherapy plans to catheter displacements. A set of 10 clinically acceptable prostate plans were re-optimized with a DTDC parameter of 0 and 0.4. For each plan, catheter displacements of 3, 7, and 14 mm were retrospectively applied and the change in dose volume histogram (DVH) indices and conformity indices analyzed. Results The robustness of clinically acceptable prostate plans to catheter displacements in the caudal direction was found to be dependent on the DTDC parameter. A DTDC value of 0 improves the robustness of planning target volume (PTV) coverage to catheter displacements, whereas a DTDC value of 0.4 improves the robustness of the plans to changes in hotspots. Conclusions The results indicate that if used in conjunction with a pre-treatment catheter displacement correction protocol and a tolerance of 3 mm, a DTDC value of 0.4 may produce clinically superior plans. However, the effect of the DTDC parameter in plan robustness was not observed to be as strong as initially suspected. PMID:27504129
Poder, Joel; Whitaker, May
2016-06-01
Inverse planning simulated annealing (IPSA) optimized brachytherapy treatment plans are characterized with large isolated dwell times at the first or last dwell position of each catheter. The potential of catheter shifts relative to the target and organs at risk in these plans may lead to a more significant change in delivered dose to the volumes of interest relative to plans with more uniform dwell times. This study aims to determine if the Nucletron Oncentra dwell time deviation constraint (DTDC) parameter can be optimized to improve the robustness of high-dose-rate (HDR) prostate brachytherapy plans to catheter displacements. A set of 10 clinically acceptable prostate plans were re-optimized with a DTDC parameter of 0 and 0.4. For each plan, catheter displacements of 3, 7, and 14 mm were retrospectively applied and the change in dose volume histogram (DVH) indices and conformity indices analyzed. The robustness of clinically acceptable prostate plans to catheter displacements in the caudal direction was found to be dependent on the DTDC parameter. A DTDC value of 0 improves the robustness of planning target volume (PTV) coverage to catheter displacements, whereas a DTDC value of 0.4 improves the robustness of the plans to changes in hotspots. The results indicate that if used in conjunction with a pre-treatment catheter displacement correction protocol and a tolerance of 3 mm, a DTDC value of 0.4 may produce clinically superior plans. However, the effect of the DTDC parameter in plan robustness was not observed to be as strong as initially suspected.
Conspicuity of target lights: The influence of color
NASA Technical Reports Server (NTRS)
Connors, M. M.
1975-01-01
The conspicuity (or attention-getting qualities) were investigated of foveally-equated, colored lights, when seen against a star background. Subjects who were periodically engaged in a distracting cockpit task were required to search a large visual field and report the appearance of a target light as quickly as possible. Targets were red, yellow, white, green, and blue, and appeared either as steady or as flashing lights. Results indicate that red targets were missed more frequently and responded to more slowly than lights of other hues. Yellow targets were acquired more slowly than white, green, or blue targets; responses to white targets were significantly slower than responses to green or blue targets. In general, flashing lights were superior to steady lights, but this was not found for all hues. For red, the 2 Hz flash was superior to all other flash rates and to the steady light, none of which differed significantly from each other. Over all hues, conspicuity was found to peak at 2-3 Hz. Response time was found to be fastest, generally, for targets appearing at between 3 and 8 from the center of the visual field. However, this pattern was not repeated for every hue. Conspicuity response times suggest a complex relationship between hue and position in the visual field that is explained only partially by retinal sensitivity.
2010-11-01
pected target motion. Along this line, Wettergren [5] analyzed the performance of the track - before - detect schemes for the sensor networks. Furthermore...dressed by Baumgartner and Ferrari [11] for the reorganization of the sensor field to achieve the maximum coverage. The track - before - detect -based optimal...confirming a target. In accordance with the track - before - detect paradigm [4], a moving target is detected if the kd (typically kd = 3 or 4) sensors detect
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rao, M; Chen, F; Cotrutz, C
2015-06-15
Purpose: To investigate the influence of respiratory motion on the delivered dose in lung stereotactic body radiotherapy (SBRT) using Cyberknife (CK) 0-View tracking mode. Methods: CT scans at inspiration and expiration of an anthropomorphic motion phantom were fused base on the spine and an internal target volume (ITV) was created. A 5mm expansion around the ITV resulted in the planning target volume. Three CK plans were generated in Accuray MultiPlan using Lung Optimization Tracking 0-View technique with the minimum MU per beam set to (a) 5MU, (b) 15MU and (c) 30MU, respectively. Doses were calculated on the expiration CT usingmore » Monte-Carlo algorithm. Each plan was delivered 5 times with a range of different starting phases in the respiratory cycle to assess the dose variation due to interplay effect. The delivered dose was measured with EBT3 Gafchromic film which was inserted in the moving target of the phantom. The target motion range is 3 cm in superior-inferior (SI) direction with the breathing period of 5 seconds. Results: The gamma analysis (5%/2mm) of the dose with the films in the transverse plane resulted in average passing rate of 95.5±4.1%, 96.7±2.6%, and 96.2±2.5% for plan (a), (b), and (c), respectively. For the sagittal films, the average passing rate was 91.1±4.9%, 92.1±3.6%, and 92.3±2.9% for the three plans, respectively. The disagreement between measurement and dose calculations were mostly on the target edges in SI direction. The mean measured versus calculated dose differences at the edge of target in SI direction were (a) 3.9±4.8%, (b) 2.4±3.3%, and (c) 2.2±3.2% for the three plans, respectively. Conclusions: The plans with low-MU beams (below 10MU) tend to cause slightly larger dose variation. However in terms of target coverage, the overall clinical dosimetric impact of the intrafraction respiratory motion in lung SBRT is insignificant when averaged over 3∼5 fractions.« less
Xu, Xianzhong; Pulavarti, Surya V S R K; Eletsky, Alexander; Huang, Yuanpeng Janet; Acton, Thomas B; Xiao, Rong; Everett, John K; Montelione, Gaetano T; Szyperski, Thomas
2014-12-01
High-quality solution NMR structures of three homeodomains from human proteins ALX4, ZHX1 and CASP8AP2 were solved. These domains were chosen as targets of a biomedical theme project pursued by the Northeast Structural Genomics Consortium. This project focuses on increasing the structural coverage of human proteins associated with cancer.
Optimizing sensor cover energy for directional sensors
NASA Astrophysics Data System (ADS)
Astorino, Annabella; Gaudioso, Manlio; Miglionico, Giovanna
2016-10-01
The Directional Sensors Continuous Coverage Problem (DSCCP) aims at covering a given set of targets in a plane by means of a set of directional sensors. The location of these sensors is known in advance and they are characterized by a discrete set of possible radii and aperture angles. Decisions to be made are about orientation (which in our approach can vary continuously), radius and aperture angle of each sensor. The objective is to get a minimum cost coverage of all targets, if any. We introduce a MINLP formulation of the problem and define a Lagrangian heuristics based on a dual ascent procedure operating on one multiplier at a time. Finally we report the results of the implementation of the method on a set of test problems.
Yu, Shanen; Xu, Yiming; Jiang, Peng; Wu, Feng; Xu, Huan
2017-01-01
At present, free-to-move node self-deployment algorithms aim at event coverage and cannot improve network coverage under the premise of considering network connectivity, network reliability and network deployment energy consumption. Thus, this study proposes pigeon-based self-deployment algorithm (PSA) for underwater wireless sensor networks to overcome the limitations of these existing algorithms. In PSA, the sink node first finds its one-hop nodes and maximizes the network coverage in its one-hop region. The one-hop nodes subsequently divide the network into layers and cluster in each layer. Each cluster head node constructs a connected path to the sink node to guarantee network connectivity. Finally, the cluster head node regards the ratio of the movement distance of the node to the change in the coverage redundancy ratio as the target function and employs pigeon swarm optimization to determine the positions of the nodes. Simulation results show that PSA improves both network connectivity and network reliability, decreases network deployment energy consumption, and increases network coverage. PMID:28338615
[Estimated mammogram coverage in Goiás State, Brazil].
Corrêa, Rosangela da Silveira; Freitas-Júnior, Ruffo; Peixoto, João Emílio; Rodrigues, Danielle Cristina Netto; Lemos, Maria Eugênia da Fonseca; Marins, Lucy Aparecida Parreira; Silveira, Erika Aparecida da
2011-09-01
This cross-sectional study aimed to estimate mammogram coverage in the State of Goiás, Brazil, describing the supply, demand, and variations in different age groups, evaluating 98 mammography services as observational units. We estimated the mammogram rates by age group and type of health service, as well as the number of tests required to cover 70% and 100% of the target population. We assessed the association between mammograms, geographical distribution of mammography machines, type of service, and age group. Full coverage estimates, considering 100% of women in the 40-69 and 50-69-year age brackets, were 61% and 66%, of which the Brazilian Unified National Health System provided 13% and 14%, respectively. To achieve 70% coverage, 43,424 additional mammograms would be needed. All the associations showed statistically significant differences (p < 0.001). We conclude that mammogram coverage is unevenly distributed in the State of Goiás and that fewer tests are performed than required.
Esthetic soft tissue management for teeth and implants.
Fu, Jia-Hui; Su, Chuan-Yi; Wang, Hom-Lay
2012-09-01
Can newly introduced graft materials be successfully used in soft tissue augmentation around teeth and dental implants? An electronic search on the PubMed database for English articles published before March 31, 2012, was performed using the following key words: "root coverage," "soft tissue graft," "periodontal plastic surgery," "subepithelial connective graft (SCTG)," "acellular dermal matrix (ADM)," "guided tissue regeneration based root coverage (GTRC)," "recession defects," "mucogingival defects," "collagen matrix," "living cellular construct (LCC)," "mucograft," and "biologic agents." Literature featuring new soft tissue graft materials, such as ADM, collagen matrix, GTRC, and biologic agents, were included. Data showed (1) allogeneic grafts were comparable to SCTG in terms of mean complete root coverage (CRC), mean root coverage (RC), and mean amount of keratinized tissue (KT) gain; (2) xenogeneic collagen matrix was as comparable to SCTG in terms of mean amount of KT gain around teeth and dental implants but inferior in achieving RC; (3) GTRC was inferior to SCTG in terms of mean CRC and mean RC; (4) LCC was inferior to free gingival graft in terms of mean amount of KT gain but was superior in esthetics and patient satisfaction; and (5) adjunctive use of biologic agents did not exert a significant effect on mean CRC, mean RC, and mean amount of KT gain. Although these new materials do not surpass the gold standard (SCTG), they do provide improved patient satisfaction and esthetics, are available in abundance, and lead to reduced postoperative discomfort and surgical time. Copyright © 2012 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Guo, Yi, E-mail: yiguo@usc.edu; Zhu, Yinghua; Lingala, Sajan Goud
Purpose: To clinically evaluate a highly accelerated T1-weighted dynamic contrast-enhanced (DCE) MRI technique that provides high spatial resolution and whole-brain coverage via undersampling and constrained reconstruction with multiple sparsity constraints. Methods: Conventional (rate-2 SENSE) and experimental DCE-MRI (rate-30) scans were performed 20 minutes apart in 15 brain tumor patients. The conventional clinical DCE-MRI had voxel dimensions 0.9 × 1.3 × 7.0 mm{sup 3}, FOV 22 × 22 × 4.2 cm{sup 3}, and the experimental DCE-MRI had voxel dimensions 0.9 × 0.9 × 1.9 mm{sup 3}, and broader coverage 22 × 22 × 19 cm{sup 3}. Temporal resolution was 5 smore » for both protocols. Time-resolved images and blood–brain barrier permeability maps were qualitatively evaluated by two radiologists. Results: The experimental DCE-MRI scans showed no loss of qualitative information in any of the cases, while achieving substantially higher spatial resolution and whole-brain spatial coverage. Average qualitative scores (from 0 to 3) were 2.1 for the experimental scans and 1.1 for the conventional clinical scans. Conclusions: The proposed DCE-MRI approach provides clinically superior image quality with higher spatial resolution and coverage than currently available approaches. These advantages may allow comprehensive permeability mapping in the brain, which is especially valuable in the setting of large lesions or multiple lesions spread throughout the brain.« less
Social hierarchy modulates neural responses of empathy for pain
Feng, Chunliang; Li, Zhihao; Feng, Xue; Wang, Lili; Tian, Tengxiang
2016-01-01
Recent evidence indicates that empathic responses to others’ pain are modulated by various situational and individual factors. However, few studies have examined how empathy and underlying brain functions are modulated by social hierarchies, which permeate human society with an enormous impact on social behavior and cognition. In this study, social hierarchies were established based on incidental skill in a perceptual task in which all participants were mediumly ranked. Afterwards, participants were scanned with functional magnetic resonance imaging while watching inferior-status or superior-status targets receiving painful or non-painful stimulation. The results revealed that painful stimulation applied to inferior-status targets induced higher activations in the anterior insula (AI) and anterior medial cingulate cortex (aMCC), whereas these empathic brain activations were significantly attenuated in response to superior-status targets’ pain. Further, this neural empathic bias to inferior-status targets was accompanied by stronger functional couplings of AI with brain regions important in emotional processing (i.e. thalamus) and cognitive control (i.e. middle frontal gyrus). Our findings indicate that emotional sharing with others’ pain is shaped by relative positions in a social hierarchy such that underlying empathic neural responses are biased toward inferior-status compared with superior-status individuals. PMID:26516169
Cyberspace Superiority: Dominating the Digital Frontier
2014-01-01
2009/07/137_48261.html. 9 Lolita Baldor, “White House among targets of cyber attack: Other targets included NSA, Homeland Security and State...attackers appeared not to get the results for 10 Lolita Baldor, "White House among targets of cyber...Communications Commission (KCC) order service providers to deny access to 30,000 13 Lolita Baldor, "US
Belknap, Aaron; Grosser, Daniel S.; Hale, Daniel A.; Lang, Benjamin J.; Colley, Peter; Benavides, Raul
2017-01-01
We performed a retrospective chart review of patients to determine if the Verigene Gram-negative blood culture (BC-GN) results would lead to earlier deescalation of empiric therapy for inpatients with GN bacteremia with Citrobacter spp., Enterobacter spp., Klebsiella spp., and Escherichia coli to appropriate targeted coverage. A total of 899 records were reviewed from April 2014 to February 2016 from three institutions within the Baylor Scott & White Health network. The cases were reviewed for initial antibiotic coverage, timing of Verigene results, change in antibiotic coverage, and how these changes related to the timing of Verigene results. The lab reported the BC-GN results and final conventional susceptibility results within 2.5 ± 1.3 and 73.6 ± 40.0 hours from the Gram stain, respectively. Overall, 29.1% of patients were transitioned from empiric to targeted therapy at 12.2 ± 13.5 hours in response to BC-GN results, which was significantly earlier (P < 0.001) than results by conventional methods. After accounting for patients already on targeted therapy, polymicrobial infections, and patients deceased or lost to follow-up, we identified antibiotic stewardship opportunities in ∼28% of GN infections. Further subanalysis demonstrated site-specific differences in the uptake of stewardship recommendations, whereby 32.4%, 50.5%, and 15.0% of cases at different hospitals demonstrated the expected change in antibiotics. These results suggest that Verigene had the expected impact in a third of the cases and the results reporting algorithm minimized the real-time involvement of the pharmacist while maintaining optimal patient management. However, this impact varied substantially by clinical site and was tempered by variable initial antibiotic coverage and clinician response. PMID:28966443
SU-F-P-31: Dosimetric Effects of Roll and Pitch Corrections Using Robotic Table
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mamalui, M; Su, Z; Flampouri, S
Purpose: To quantify the dosimetric effect of roll and pitch corrections being performed by two types of robotic tables available at our institution: BrainLabTM 5DOF robotic table installed at VERO (BrainLab&MHI) dedicated SBRT linear accelerator and 6DOF robotic couch by IBA Proton Therapy with QFixTM couch top. Methods: Planning study used a thorax phantom (CIRSTM), scanned at 4DCT protocol; targets (IGTV, PTV) were determined according to the institutional lung site-specific standards. 12 CT sets were generated with Pitch and Roll angles ranging from −4 to +4 degrees each. 2 table tops were placed onto the scans according to the modality-specificmore » patient treatment workflows. The pitched/rolled CT sets were fused to the original CT scan and the verification treatment plans were generated (12 photon SBRT plans and 12 proton conventional fractionation lung plans). Then the CT sets were fused again to simulate the effect of patient roll/pitch corrections by the robotic table. DVH sets were evaluated for all cases. Results: The effect of not correcting the phantom position for roll/pitch in photon SBRT cases was reducing the target coverage by 2% as maximum; correcting the positional errors by robotic table varied the target coverage within 0.7%. in case of proton treatment, not correcting the phantom position led to the coverage loss up to 4%, applying the corrections using robotic table reduced the coverage variation to less than 2% for PTV and within 1% for IGTV. Conclusion: correcting the patient position by using robotic tables is highly preferable, despite the small dosimetric changes introduced by the devices.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ashenafi, M; McDonald, D; Peng, J
Purpose: Improved patient imaging used for planning the treatment of cervical cancer with Tandem and Ovoid (T&O) Intracavitary high-dose-rate brachytherapy (HDR) now allows for 3D delineation of target volumes and organs-at-risk. However, historical data relies on the conventional point A-based planning technique. A comparative dosimetric study was performed by generating both target-based (TBP) and point-based (PBP) plans for ten clinical patients. Methods: Treatment plans created using Elekta Oncentra v. 4.3 for ten consecutive cervical cancer patients were analyzed. All patients were treated with HDR using the Utrecht T&O applicator. Both CT and MRI imaging modalities were utilized to delineate clinicalmore » target volume (CTV) and organs-at-risk (rectum, sigmoid, bladder, and small bowel). Point A (left and right), vaginal mucosa, and ICRU rectum and bladder points were defined on CT. Two plans were generated for each patient using two prescription methods (PBP and TBP). 7Gy was prescribed to each point A for each PBP plan and to the target D90% for each TBP plan. Target V90%, V100%, and V200% were evaluated. In addition, D0.1cc and D2cc were analyzed for each organ-at-risk. Differences were assessed for statistical significance (p<0.05) by use of Student’s t-test. Results: Target coverage was comparable for both planning methods, with each method providing adequate target coverage. TBP showed lower absolute dose to the target volume than PBP (D90% = 7.0Gy vs. 7.4Gy, p=0.028), (V200% = 10.9cc vs. 12.8cc, p=0.014), (ALeft = 6.4Gy vs. 7Gy, p=0.009), and (ARight = 6.4Gy vs. 7Gy, p=0.013). TBP also showed a statistically significant reduction in bladder, rectum, small bowel, and sigmoid doses compared to PBP. There was no statistically significant difference in vaginal mucosa or ICRU-defined rectum and bladder dose. Conclusion: Target based prescription resulted in substantially lower dose to delineated organs-at-risk compared to point based prescription, while maintaining similar target coverage.« less
Generalizing Evidence From Randomized Clinical Trials to Target Populations
Cole, Stephen R.; Stuart, Elizabeth A.
2010-01-01
Properly planned and conducted randomized clinical trials remain susceptible to a lack of external validity. The authors illustrate a model-based method to standardize observed trial results to a specified target population using a seminal human immunodeficiency virus (HIV) treatment trial, and they provide Monte Carlo simulation evidence supporting the method. The example trial enrolled 1,156 HIV-infected adult men and women in the United States in 1996, randomly assigned 577 to a highly active antiretroviral therapy and 579 to a largely ineffective combination therapy, and followed participants for 52 weeks. The target population was US people infected with HIV in 2006, as estimated by the Centers for Disease Control and Prevention. Results from the trial apply, albeit muted by 12%, to the target population, under the assumption that the authors have measured and correctly modeled the determinants of selection that reflect heterogeneity in the treatment effect. In simulations with a heterogeneous treatment effect, a conventional intent-to-treat estimate was biased with poor confidence limit coverage, but the proposed estimate was largely unbiased with appropriate confidence limit coverage. The proposed method standardizes observed trial results to a specified target population and thereby provides information regarding the generalizability of trial results. PMID:20547574
Resolution Enhanced Magnetic Sensing System for Wide Coverage Real Time UXO Detection
NASA Astrophysics Data System (ADS)
Zalevsky, Zeev; Bregman, Yuri; Salomonski, Nizan; Zafrir, Hovav
2012-09-01
In this paper we present a new high resolution automatic detection algorithm based upon a Wavelet transform and then validate it in marine related experiments. The proposed approach allows obtaining an automatic detection in a very low signal to noise ratios. The amount of calculations is reduced, the magnetic trend is depressed and the probability of detection/ false alarm rate can easily be controlled. Moreover, the algorithm enables to distinguish between close targets. In the algorithm we use the physical dependence of the magnetic field of a magnetic dipole in order to define a Wavelet mother function that later on can detect magnetic targets modeled as dipoles and embedded in noisy surrounding, at improved resolution. The proposed algorithm was realized on synthesized targets and then validated in field experiments involving a marine surface-floating system for wide coverage real time unexploded ordinance (UXO) detection and mapping. The detection probability achieved in the marine experiment was above 90%. The horizontal radial error of most of the detected targets was only 16 m and two baseline targets that were immersed about 20 m one to another could easily be distinguished.
NASA Astrophysics Data System (ADS)
Jiang, Runqing; Barnett, Rob B.; Chow, James C. L.; Chen, Jeff Z. Y.
2007-03-01
The aim of this study is to investigate the effects of internal organ motion on IMRT treatment planning of prostate patients using a spatial dose gradient and probability density function. Spatial dose distributions were generated from a Pinnacle3 planning system using a co-planar, five-field intensity modulated radiation therapy (IMRT) technique. Five plans were created for each patient using equally spaced beams but shifting the angular displacement of the beam by 15° increments. Dose profiles taken through the isocentre in anterior-posterior (A-P), right-left (R-L) and superior-inferior (S-I) directions for IMRT plans were analysed by exporting RTOG file data from Pinnacle. The convolution of the 'static' dose distribution D0(x, y, z) and probability density function (PDF), denoted as P(x, y, z), was used to analyse the combined effect of repositioning error and internal organ motion. Organ motion leads to an enlarged beam penumbra. The amount of percentage mean dose deviation (PMDD) depends on the dose gradient and organ motion probability density function. Organ motion dose sensitivity was defined by the rate of change in PMDD with standard deviation of motion PDF and was found to increase with the maximum dose gradient in anterior, posterior, left and right directions. Due to common inferior and superior field borders of the field segments, the sharpest dose gradient will occur in the inferior or both superior and inferior penumbrae. Thus, prostate motion in the S-I direction produces the highest dose difference. The PMDD is within 2.5% when standard deviation is less than 5 mm, but the PMDD is over 2.5% in the inferior direction when standard deviation is higher than 5 mm in the inferior direction. Verification of prostate organ motion in the inferior directions is essential. The margin of the planning target volume (PTV) significantly impacts on the confidence of tumour control probability (TCP) and level of normal tissue complication probability (NTCP). Smaller margins help to reduce the dose to normal tissues, but may compromise the dose coverage of the PTV. Lower rectal NTCP can be achieved by either a smaller margin or a steeper dose gradient between PTV and rectum. With the same DVH control points, the rectum has lower complication in the seven-beam technique used in this study because of the steeper dose gradient between the target volume and rectum. The relationship between dose gradient and rectal complication can be used to evaluate IMRT treatment planning. The dose gradient analysis is a powerful tool to improve IMRT treatment plans and can be used for QA checking of treatment plans for prostate patients.
Jiang, Runqing; Barnett, Rob B; Chow, James C L; Chen, Jeff Z Y
2007-03-07
The aim of this study is to investigate the effects of internal organ motion on IMRT treatment planning of prostate patients using a spatial dose gradient and probability density function. Spatial dose distributions were generated from a Pinnacle3 planning system using a co-planar, five-field intensity modulated radiation therapy (IMRT) technique. Five plans were created for each patient using equally spaced beams but shifting the angular displacement of the beam by 15 degree increments. Dose profiles taken through the isocentre in anterior-posterior (A-P), right-left (R-L) and superior-inferior (S-I) directions for IMRT plans were analysed by exporting RTOG file data from Pinnacle. The convolution of the 'static' dose distribution D0(x, y, z) and probability density function (PDF), denoted as P(x, y, z), was used to analyse the combined effect of repositioning error and internal organ motion. Organ motion leads to an enlarged beam penumbra. The amount of percentage mean dose deviation (PMDD) depends on the dose gradient and organ motion probability density function. Organ motion dose sensitivity was defined by the rate of change in PMDD with standard deviation of motion PDF and was found to increase with the maximum dose gradient in anterior, posterior, left and right directions. Due to common inferior and superior field borders of the field segments, the sharpest dose gradient will occur in the inferior or both superior and inferior penumbrae. Thus, prostate motion in the S-I direction produces the highest dose difference. The PMDD is within 2.5% when standard deviation is less than 5 mm, but the PMDD is over 2.5% in the inferior direction when standard deviation is higher than 5 mm in the inferior direction. Verification of prostate organ motion in the inferior directions is essential. The margin of the planning target volume (PTV) significantly impacts on the confidence of tumour control probability (TCP) and level of normal tissue complication probability (NTCP). Smaller margins help to reduce the dose to normal tissues, but may compromise the dose coverage of the PTV. Lower rectal NTCP can be achieved by either a smaller margin or a steeper dose gradient between PTV and rectum. With the same DVH control points, the rectum has lower complication in the seven-beam technique used in this study because of the steeper dose gradient between the target volume and rectum. The relationship between dose gradient and rectal complication can be used to evaluate IMRT treatment planning. The dose gradient analysis is a powerful tool to improve IMRT treatment plans and can be used for QA checking of treatment plans for prostate patients.
Zaghian, Maryam; Cao, Wenhua; Liu, Wei; Kardar, Laleh; Randeniya, Sharmalee; Mohan, Radhe; Lim, Gino
2017-03-01
Robust optimization of intensity-modulated proton therapy (IMPT) takes uncertainties into account during spot weight optimization and leads to dose distributions that are resilient to uncertainties. Previous studies demonstrated benefits of linear programming (LP) for IMPT in terms of delivery efficiency by considerably reducing the number of spots required for the same quality of plans. However, a reduction in the number of spots may lead to loss of robustness. The purpose of this study was to evaluate and compare the performance in terms of plan quality and robustness of two robust optimization approaches using LP and nonlinear programming (NLP) models. The so-called "worst case dose" and "minmax" robust optimization approaches and conventional planning target volume (PTV)-based optimization approach were applied to designing IMPT plans for five patients: two with prostate cancer, one with skull-based cancer, and two with head and neck cancer. For each approach, both LP and NLP models were used. Thus, for each case, six sets of IMPT plans were generated and assessed: LP-PTV-based, NLP-PTV-based, LP-worst case dose, NLP-worst case dose, LP-minmax, and NLP-minmax. The four robust optimization methods behaved differently from patient to patient, and no method emerged as superior to the others in terms of nominal plan quality and robustness against uncertainties. The plans generated using LP-based robust optimization were more robust regarding patient setup and range uncertainties than were those generated using NLP-based robust optimization for the prostate cancer patients. However, the robustness of plans generated using NLP-based methods was superior for the skull-based and head and neck cancer patients. Overall, LP-based methods were suitable for the less challenging cancer cases in which all uncertainty scenarios were able to satisfy tight dose constraints, while NLP performed better in more difficult cases in which most uncertainty scenarios were hard to meet tight dose limits. For robust optimization, the worst case dose approach was less sensitive to uncertainties than was the minmax approach for the prostate and skull-based cancer patients, whereas the minmax approach was superior for the head and neck cancer patients. The robustness of the IMPT plans was remarkably better after robust optimization than after PTV-based optimization, and the NLP-PTV-based optimization outperformed the LP-PTV-based optimization regarding robustness of clinical target volume coverage. In addition, plans generated using LP-based methods had notably fewer scanning spots than did those generated using NLP-based methods. © 2017 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.
Msyamboza, Kelias Phiri; Mwagomba, Beatrice Matanje; Valle, Moussa; Chiumia, Hastings; Phiri, Twambilire
2017-06-26
Cervical cancer is a major public health problem in Malawi. The age-standardized incidence and mortality rates are estimated to be 75.9 and 49.8 per 100,000 population, respectively. The availability of the human papillomavirus (HPV) vaccine presents an opportunity to reduce the morbidity and mortality associated with cervical cancer. In 2013, the country introduced a school-class-based HPV vaccination pilot project in two districts. The aim of this study was to evaluate HPV vaccine coverage, lessons learnt and challenges identified during the first three years of implementation. This was an evaluation of the HPV vaccination project targeting adolescent girls aged 9-13 years conducted in Malawi from 2013 to 2016. We analysed programme data, supportive supervision reports and minutes of National HPV Task Force meetings to determine HPV vaccine coverage, reasons for partial or no vaccination and challenges. Administrative coverage was validated using a community-based coverage survey. A total of 26,766 in-school adolescent girls were fully vaccinated in the two pilot districts during the first three years of the programme. Of these; 2051 (7.7%) were under the age of 9 years, 884 (3.3%) were over the age of 13 years, and 23,831 (89.0%) were aged 9-13 years (the recommended age group). Of the 765 out-of-school adolescent girls aged 9-13 who were identified during the period, only 403 (52.7%) were fully vaccinated. In Zomba district, the coverage rates of fully vaccinated were 84.7%, 87.6% and 83.3% in year 1, year 2 and year 3 of the project, respectively. The overall coverage for the first three years was 82.7%, and the dropout rate was 7.7%. In Rumphi district, the rates of fully vaccinated coverage were 90.2% and 96.2% in year 1 and year 2, respectively, while the overall coverage was 91.3%, and the dropout rate was 4.9%. Administrative (facility-based) coverage for the first year was validated using a community-based cluster coverage survey. The majority of the coverage results were statistically similar, except for in Rumphi district, where community-based 3-dose coverage was higher than the corresponding administrative-coverage (94.2% vs 90.2%, p < 0.05), and overall (in both districts), facility-based 1-dose coverage was higher than the corresponding community-based (94.6% vs 92.6%, p < 0.05). Transferring out of the district, dropping out of school and refusal were some of the reasons for partial or no uptake of the vaccine. In Malawi, the implementation of a school-class-based HPV vaccination strategy was feasible and produced high (>80%) coverage. However, this strategy may be associated with the vaccination of under- and over-aged adolescent girls who are outside of the vaccine manufacturer's stipulated age group (9-13 years). The health facility-based coverage for out-of-school adolescent girls produced low coverage, with only half of the target population being fully vaccinated. These findings highlight the need to assess the immunogenicity associated with the administration of a two-dose schedule to adolescent girls younger or older than 9-13 years and effectiveness of health facility-based strategy before rolling out the programme.
The JCSG high-throughput structural biology pipeline.
Elsliger, Marc André; Deacon, Ashley M; Godzik, Adam; Lesley, Scott A; Wooley, John; Wüthrich, Kurt; Wilson, Ian A
2010-10-01
The Joint Center for Structural Genomics high-throughput structural biology pipeline has delivered more than 1000 structures to the community over the past ten years. The JCSG has made a significant contribution to the overall goal of the NIH Protein Structure Initiative (PSI) of expanding structural coverage of the protein universe, as well as making substantial inroads into structural coverage of an entire organism. Targets are processed through an extensive combination of bioinformatics and biophysical analyses to efficiently characterize and optimize each target prior to selection for structure determination. The pipeline uses parallel processing methods at almost every step in the process and can adapt to a wide range of protein targets from bacterial to human. The construction, expansion and optimization of the JCSG gene-to-structure pipeline over the years have resulted in many technological and methodological advances and developments. The vast number of targets and the enormous amounts of associated data processed through the multiple stages of the experimental pipeline required the development of variety of valuable resources that, wherever feasible, have been converted to free-access web-based tools and applications.
Draft versus finished sequence data for DNA and protein diagnostic signature development
Gardner, Shea N.; Lam, Marisa W.; Smith, Jason R.; Torres, Clinton L.; Slezak, Tom R.
2005-01-01
Sequencing pathogen genomes is costly, demanding careful allocation of limited sequencing resources. We built a computational Sequencing Analysis Pipeline (SAP) to guide decisions regarding the amount of genomic sequencing necessary to develop high-quality diagnostic DNA and protein signatures. SAP uses simulations to estimate the number of target genomes and close phylogenetic relatives (near neighbors or NNs) to sequence. We use SAP to assess whether draft data are sufficient or finished sequencing is required using Marburg and variola virus sequences. Simulations indicate that intermediate to high-quality draft with error rates of 10−3–10−5 (∼8× coverage) of target organisms is suitable for DNA signature prediction. Low-quality draft with error rates of ∼1% (3× to 6× coverage) of target isolates is inadequate for DNA signature prediction, although low-quality draft of NNs is sufficient, as long as the target genomes are of high quality. For protein signature prediction, sequencing errors in target genomes substantially reduce the detection of amino acid sequence conservation, even if the draft is of high quality. In summary, high-quality draft of target and low-quality draft of NNs appears to be a cost-effective investment for DNA signature prediction, but may lead to underestimation of predicted protein signatures. PMID:16243783
Hoffmann, Thomas J; Zhan, Yiping; Kvale, Mark N; Hesselson, Stephanie E; Gollub, Jeremy; Iribarren, Carlos; Lu, Yontao; Mei, Gangwu; Purdy, Matthew M; Quesenberry, Charles; Rowell, Sarah; Shapero, Michael H; Smethurst, David; Somkin, Carol P; Van den Eeden, Stephen K; Walter, Larry; Webster, Teresa; Whitmer, Rachel A; Finn, Andrea; Schaefer, Catherine; Kwok, Pui-Yan; Risch, Neil
2011-12-01
Four custom Axiom genotyping arrays were designed for a genome-wide association (GWA) study of 100,000 participants from the Kaiser Permanente Research Program on Genes, Environment and Health. The array optimized for individuals of European race/ethnicity was previously described. Here we detail the development of three additional microarrays optimized for individuals of East Asian, African American, and Latino race/ethnicity. For these arrays, we decreased redundancy of high-performing SNPs to increase SNP capacity. The East Asian array was designed using greedy pairwise SNP selection. However, removing SNPs from the target set based on imputation coverage is more efficient than pairwise tagging. Therefore, we developed a novel hybrid SNP selection method for the African American and Latino arrays utilizing rounds of greedy pairwise SNP selection, followed by removal from the target set of SNPs covered by imputation. The arrays provide excellent genome-wide coverage and are valuable additions for large-scale GWA studies. Copyright © 2011 Elsevier Inc. All rights reserved.
Introduction of novel 3D-printed superficial applicators for high-dose-rate skin brachytherapy.
Jones, Emma-Louise; Tonino Baldion, Anna; Thomas, Christopher; Burrows, Tom; Byrne, Nick; Newton, Victoria; Aldridge, Sarah
Custom-made surface mold applicators often allow more flexibility when carrying out skin brachytherapy, particularly for small treatment areas with high surface obliquity. They can, however, be difficult to manufacture, particularly if there is a lack of experience in superficial high-dose-rate brachytherapy techniques or with limited resources. We present a novel method of manufacturing superficial brachytherapy applicators utilizing three-dimensional (3D)-printing techniques. We describe the treatment planning process and the process of applicator manufacture. The treatment planning process, with the introduction of a pre-plan, allows for an "ideal" catheter arrangement within an applicator to be determined, exploiting varying catheter orientations, heights, and curvatures if required. The pre-plan arrangement is then 3D printed to the exact specifications of the pre-plan applicator design. This results in improved target volume coverage and improved sparing of organs at risk. Using a pre-plan technique for ideal catheter placement followed by automated 3D-printed applicator manufacture has greatly improved the entire process of superficial high-dose-rate brachytherapy treatment. We are able to design and manufacture flexible, well-fitting, superior quality applicators resulting in a more efficient and improved patient pathway and patient experience. Copyright © 2016 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.
Sivasankaran, Saravanan; Manickam, P; Ramakrishnan, R; Hutin, Y; Gupte, M D
2006-04-28
As part of the global strategic plan to reduce the number of measles deaths in India, the state of Tamilnadu aims at > or =95% measles vaccination coverage. A study was conducted to measure overall coverage levels for the Poondi Primary Health Center (PPHC), a rural health-care facility in Tiruvallur District, and to determine whether any of the PPHC's six health subcenters had coverage levels <95%. The Lot Quality Assurance Sampling (LQAS) method was used to identify health subcenters in the PPHC area with measles vaccination coverage levels <95% among children aged 12-23 months. Lemeshow and Taber sampling plans were used to determine that the measles vaccination status of 73 children aged 12--23 months had to be assessed in each health subcenter coverage area, with a 5% level of significance and a decision value of two. If more than two children were unvaccinated, the null hypothesis (i.e., that coverage in the health subcenter was low [<95%]) was not rejected. If the number of unvaccinated children was two or fewer, the null hypothesis was rejected, and coverage in the subcenter was considered to be good (i.e., > or =95%). All data were pooled in a stratified sample to estimate overall total coverage in the PPHC area. For two (33.3%) of the six health subcenters, more than two children were unvaccinated (i.e., coverage was <95%). Combining results from all six health subcenters generated a coverage estimate of 97.7% (95% confidence interval = 95.7-98.8) on the basis of 428 (97.7%) of 438 children identified as vaccinated. LQAS techniques proved useful in identifying small health areas with lower vaccination coverage, which helps to target interventions. Monthly review of vaccination coverage by subcenter and village is recommended to identify pockets of unvaccinated children and to maintain uniform high coverage in the PPHC area.
Assessment of on-time vaccination coverage in population subgroups: A record linkage cohort study.
Moore, Hannah C; Fathima, Parveen; Gidding, Heather F; de Klerk, Nicholas; Liu, Bette; Sheppeard, Vicky; Effler, Paul V; Snelling, Thomas L; McIntyre, Peter; Blyth, Christopher C
2018-05-31
Reported infant vaccination coverage at age 12 months in Australia is >90%. On-time coverage of the 2-4-6 month schedule and coverage in specific populations is rarely reported. We conducted a population-based cohort study of 1.9 million Australian births, 1996-2012, combining individual birth and perinatal records with immunisation records through probabilistic linkage. We assessed on-time coverage across 13 demographic and perinatal characteristics of diphtheria-tetanus-pertussis vaccines (DTP) defined as vaccination 14 days prior to the scheduled due date, to 30 days afterwards. On-time DTP vaccination coverage in non-Aboriginal infants was 88.1% for the 2-month dose, 82.0% for 4-month dose, and 76.7% for 6-month dose; 3-dose coverage was 91.3% when assessed at 12 months. On-time DTP coverage for Aboriginal infants was 77.0%, 66.5%, and 61.0% for the 2-4-6 month dose; 3-dose coverage at 12 months was 79.3%. Appreciable differences in on-time coverage were observed across population subgroups. On-time coverage in non-Aboriginal infants born to mothers with ≥3 previous pregnancies was 62.5% for the 6-month dose (47.9% for Aboriginal infants); up to 23.5 percentage points lower than for first-borns. Infants born to mothers who smoked during pregnancy had coverage 8.7-10.3 percentage points lower than infants born to non-smoking mothers for the 4- and 6-month dose. A linear relationship was apparent between increasing socio-economic disadvantage and decreasing on-time coverage. On-time coverage of the 2-4-6 month schedule is only 50-60% across specific population subgroups representing a significant avoidable public health risk. Aboriginal infants, multiparous mothers, and those who are socio-economically disadvantaged are key groups most likely to benefit from targeted programs addressing vaccine timeliness. Copyright © 2018. Published by Elsevier Ltd.
Greenland, K; Rondy, M; Chevez, A; Sadozai, N; Gasasira, A; Abanida, E A; Pate, M A; Ronveaux, O; Okayasu, H; Pedalino, B; Pezzoli, L
2011-07-01
To evaluate oral poliovirus vaccine (OPV) coverage of the November 2009 round in five Northern Nigeria states with ongoing wild poliovirus transmission using clustered lot quality assurance sampling (CLQAS). We selected four local government areas in each pre-selected state and sampled six clusters of 10 children in each Local Government Area, defined as the lot area. We used three decision thresholds to classify OPV coverage: 75-90%, 55-70% and 35-50%. A full lot was completed, but we also assessed in retrospect the potential time-saving benefits of stopping sampling when a lot had been classified. We accepted two local government areas (LGAs) with vaccination coverage above 75%. Of the remaining 18 rejected LGAs, 11 also failed to reach 70% coverage, of which four also failed to reach 50%. The average time taken to complete a lot was 10 h. By stopping sampling when a decision was reached, we could have classified lots in 5.3, 7.7 and 7.3 h on average at the 90%, 70% and 50% coverage targets, respectively. Clustered lot quality assurance sampling was feasible and useful to estimate OPV coverage in Northern Nigeria. The multi-threshold approach provided useful information on the variation of IPD vaccination coverage. CLQAS is a very timely tool, allowing corrective actions to be directly taken in insufficiently covered areas. © 2011 Blackwell Publishing Ltd.
NASA Astrophysics Data System (ADS)
Goldsby, Anthony Lee
Increasing water scarcity may result in greater irrigation restrictions for turfgrass. Drought tolerance and recovery of Kentucky bluegrasses ( Poa. pratensis L.) (KBG) were evaluated during and after 88 and 60 day dry downs in 2010 and 2011, respectively, under a rainout shelter. Changes in green coverage were evaluated with digital images. Green coverage declined slowest during dry downs and increased fastest during recoveries in the cultivar 'Apollo', indicating it had superior drought tolerance. Electrolyte leakage, photosynthesis, and leaf water potential were evaluated in 7 KBG cultivars during and after the dry downs. Soil moisture at 5 and 20 cm was measured. There were generally no differences in physiological parameters among cultivars during or after dry down. The highest reduction in soil moisture at 5 and 20 cm was in Apollo, suggesting it had a better developed root system for mining water from the profile during drought. Weed prevention and turfgrass establishment of 'Legacy' buffalograss (Buchloe dactyloides [Nutt.] Engelm.) and 'Chisholm' zoysiagrass (Zoysia japonica Steud.) grown on turf reinforcement mats (TRM) was evaluated. 'Chisholm' zoysiagrass stolons grew under the TRM; as such, use of TRM for this cultivar is not practical. Buffalograss had 90% or greater coverage when established on TRM in 2010 and 65% or greater coverage in 2011; coverage was similar to that in oxadiazon-treated plots at the end of each year. 'Legacy' buffalograss plugs were established on TRM over plastic for 3 weeks, stored in TRM under tree shade for 7, 14, or 21 days, and evaluated for establishment after storage. In 2010, plugs on mats stored for 7 days had similar coverage to the control, but in 2011 displayed similar coverage to plugs stored on TRM for 14 or 21 day treatments. Green leaf are index (LAI) is an important indicator of turfgrass performance, but its measurement is time consuming and destructive. Measurements using hyperspectral radiometry were compared with destructive measurements of LAI. Results suggest spectral radiometry has potential to accurately predict LAI. The robustness of prediction models varied over the growing season. Finding one model to predict LAI across and entire growing season still seems unrealistic.
Allnutt, Thomas F.; McClanahan, Timothy R.; Andréfouët, Serge; Baker, Merrill; Lagabrielle, Erwann; McClennen, Caleb; Rakotomanjaka, Andry J. M.; Tianarisoa, Tantely F.; Watson, Reg; Kremen, Claire
2012-01-01
The Government of Madagascar plans to increase marine protected area coverage by over one million hectares. To assist this process, we compare four methods for marine spatial planning of Madagascar's west coast. Input data for each method was drawn from the same variables: fishing pressure, exposure to climate change, and biodiversity (habitats, species distributions, biological richness, and biodiversity value). The first method compares visual color classifications of primary variables, the second uses binary combinations of these variables to produce a categorical classification of management actions, the third is a target-based optimization using Marxan, and the fourth is conservation ranking with Zonation. We present results from each method, and compare the latter three approaches for spatial coverage, biodiversity representation, fishing cost and persistence probability. All results included large areas in the north, central, and southern parts of western Madagascar. Achieving 30% representation targets with Marxan required twice the fish catch loss than the categorical method. The categorical classification and Zonation do not consider targets for conservation features. However, when we reduced Marxan targets to 16.3%, matching the representation level of the “strict protection” class of the categorical result, the methods show similar catch losses. The management category portfolio has complete coverage, and presents several management recommendations including strict protection. Zonation produces rapid conservation rankings across large, diverse datasets. Marxan is useful for identifying strict protected areas that meet representation targets, and minimize exposure probabilities for conservation features at low economic cost. We show that methods based on Zonation and a simple combination of variables can produce results comparable to Marxan for species representation and catch losses, demonstrating the value of comparing alternative approaches during initial stages of the planning process. Choosing an appropriate approach ultimately depends on scientific and political factors including representation targets, likelihood of adoption, and persistence goals. PMID:22359534
Allnutt, Thomas F; McClanahan, Timothy R; Andréfouët, Serge; Baker, Merrill; Lagabrielle, Erwann; McClennen, Caleb; Rakotomanjaka, Andry J M; Tianarisoa, Tantely F; Watson, Reg; Kremen, Claire
2012-01-01
The Government of Madagascar plans to increase marine protected area coverage by over one million hectares. To assist this process, we compare four methods for marine spatial planning of Madagascar's west coast. Input data for each method was drawn from the same variables: fishing pressure, exposure to climate change, and biodiversity (habitats, species distributions, biological richness, and biodiversity value). The first method compares visual color classifications of primary variables, the second uses binary combinations of these variables to produce a categorical classification of management actions, the third is a target-based optimization using Marxan, and the fourth is conservation ranking with Zonation. We present results from each method, and compare the latter three approaches for spatial coverage, biodiversity representation, fishing cost and persistence probability. All results included large areas in the north, central, and southern parts of western Madagascar. Achieving 30% representation targets with Marxan required twice the fish catch loss than the categorical method. The categorical classification and Zonation do not consider targets for conservation features. However, when we reduced Marxan targets to 16.3%, matching the representation level of the "strict protection" class of the categorical result, the methods show similar catch losses. The management category portfolio has complete coverage, and presents several management recommendations including strict protection. Zonation produces rapid conservation rankings across large, diverse datasets. Marxan is useful for identifying strict protected areas that meet representation targets, and minimize exposure probabilities for conservation features at low economic cost. We show that methods based on Zonation and a simple combination of variables can produce results comparable to Marxan for species representation and catch losses, demonstrating the value of comparing alternative approaches during initial stages of the planning process. Choosing an appropriate approach ultimately depends on scientific and political factors including representation targets, likelihood of adoption, and persistence goals.
Hodges, Mary H; Sesay, Fatmata F; Kamara, Habib I; Turay, Mohamed; Koroma, Aminata S; Blankenship, Jessica L; Katcher, Heather I
2013-08-01
In Sierra Leone, children ages 6-59 months receive twice-yearly vitamin A supplementation (VAS) through Maternal and Child Health Week (MCHW) events. VAS coverage in 2011 was calculated using government tally sheets of vitamin A capsule distribution and outdated population projections from the 2004 census. We conducted a national post-event coverage (PEC) survey to validate coverage and inform strategies to reach universal coverage of VAS in Sierra Leone. Immediately following the November 2011 MCHW event, we conducted a national PEC survey by interviewing caregivers with children ages 6-59 months using a randomized 30X30 cluster design (N = 900). We also interviewed one health worker and one community health worker in each cluster to determine their knowledge about VAS (N = 60). VAS coverage was 91.8% among children ages 6-59 months, which was lower than the 105.1% reported through tally sheets. Coverage was high and equitable among all districts and between age groups (98.5% for infants ages 6-11 months and 90.5% for children ages 12-59 months). Major reasons for not receiving VAS were that the child was out of the area (42.4%), the household was not visited by community health workers (28.0%), and the caretaker was not aware of the event (11.9%). Twice-yearly delivery of VAS through MCHW events achieved consistently high and equitable coverage in Sierra Leone. Universal coverage may be achieved through continued focus on communication and targeted outreach to hard-to-reach areas during the MCHWs.
Reeder, Anthony I; Gray, Andrew R; Liley, J Ben; Scragg, Robert K R; McKenzie, Richard L; Stewart, Alistair W
2016-03-01
Clothing coverage is important for reducing skin cancer risk, but may also influence vitamin D sufficiency, so associated plausible predictors require investigation. Volunteers (18 to 85 years), with approximately equal numbers by sex and four ethnicity groups, were recruited in cities from two latitude bands: Auckland (36.9°S) and Dunedin (45.9°S). Baseline questionnaire, anthropometric and spectrophotometer skin colour data were collected and weather data obtained. Percent body coverage was calculated from eight week diary records. Potential independent predictors (unadjusted p < 0.25) were included in adjusted models. Participants (n = 506: Auckland n = 334, Dunedin n = 172; mean age 48.4 years) were 62.7% female and had a median body clothing coverage of 81.6% (IQR 9.3%). Dunedin was cooler, less windy and had lower UVI levels than Auckland. From the fully adjusted model, increased coverage occurred in non-summer months (despite adjusting for weather), among Dunedin residents and Asians (compared to Europeans), during the middle of the day, with a dose response effect observed for greater age. Reduced coverage was associated with Pacific ethnicity and greater time spent outdoors. Additionally, higher temperatures were associated with reduced coverage, whereas increased cloud cover and wind speed were associated with increased coverage. Although the only potentially modifiable factors associated with clothing coverage were the time period and time spent outdoors, knowledge of these and other associated factors is useful for the framing and targeting of health promotion messages to potentially influence clothing coverage, facilitate erythema avoidance and maintain vitamin D sufficiency.
Set-up uncertainties: online correction with X-ray volume imaging.
Kataria, Tejinder; Abhishek, Ashu; Chadha, Pranav; Nandigam, Janardhan
2011-01-01
To determine interfractional three-dimensional set-up errors using X-ray volumetric imaging (XVI). Between December 2007 and August 2009, 125 patients were taken up for image-guided radiotherapy using online XVI. After matching of reference and acquired volume view images, set-up errors in three translation directions were recorded and corrected online before treatment each day. Mean displacements, population systematic (Σ), and random (σ) errors were calculated and analyzed using SPSS (v16) software. Optimum clinical target volume (CTV) to planning target volume (PTV) margin was calculated using Van Herk's (2.5Σ + 0.7 σ) and Stroom's (2Σ + 0.7 σ) formula. Patients were grouped in 4 cohorts, namely brain, head and neck, thorax, and abdomen-pelvis. The mean vector displacement recorded were 0.18 cm, 0.15 cm, 0.36 cm, and 0.35 cm for brain, head and neck, thorax, and abdomen-pelvis, respectively. Analysis of individual mean set-up errors revealed good agreement with the proposed 0.3 cm isotropic margins for brain and 0.5 cm isotropic margins for head-neck. Similarly, 0.5 cm circumferential and 1 cm craniocaudal proposed margins were in agreement with thorax and abdomen-pelvic cases. The calculated mean displacements were well within CTV-PTV margin estimates of Van Herk (90% population coverage to minimum 95% prescribed dose) and Stroom (99% target volume coverage by 95% prescribed dose). Employing these individualized margins in a particular cohort ensure comparable target coverage as described in literature, which is further improved if XVI-aided set-up error detection and correction is used before treatment.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hong, L; Ballangrud, A; Mechalakos, J
Purpose: For left-sided PU patients requiring CW and nodal irradiation, sometimes partial wide tangents (PWT) are not feasible due to abnormal chest wall contour or heart position close to the anterior chest wall or unusual wide excision scar. We developed an energy modulated electron chest wall irradiation technique that will achieve heart sparing. Methods: Ten left-sided PU patients were selected for this dosimetry study. If PWT were used, the amount of the ipsilateral lung would be ranged 3.4 to 4.4 cm, and the amount of heart would be ranged 1.3 to 3.8 cm. We used electron paired fields that matchedmore » on the skin to achieve dose conformity to the chest wall. The enface electron fields were designed at extended SSD from a single isocenter and gantry angle with different energy beams using different cutout. Lower energy was used in the central chest wall part and higher energy was used in the periphery of the chest wall. Bolus was used for the electron fields to ensure adequate skin dose coverage. The electron fields were matched to the photon supra-clavicle field in the superior region. Daily field junctions were used to feather the match lines between all the fields. Target volumes and normal tissues were drawn according to institutional protocols. Prescription dose was 2Gy per fraction for a total 50Gy. Dose calculations were done with Eclipse EMC-11031 for Electron and AAA-11031 for photons. Results: Six patients were planned using 6/9MeV, three using 9/12MeV and one 6/12MeV. Target volumes achieved adequate coverage. For heart, V30Gy, V20Gy and Mean Dose were 0.6%±0.6%, 2.7%±1.7%, and 3.0Gy±0.8Gy respectively. For ipsilateral lung, V50Gy, V20Gy, V10Gy and V5Gy were 0.9%±1.1%, 34.3%±5.1%, 51.6%±6.3% and 64.1%±7.5% respectively. Conclusion: For left-sided PU patients with unusual anatomy, energy modulated electron CW irradiation technique can achieve heart sparing with acceptable lung dose.« less
Trofimov, Alexei; Unkelbach, Jan; DeLaney, Thomas F; Bortfeld, Thomas
2012-01-01
Dose-volume histograms (DVH) are the most common tool used in the appraisal of the quality of a clinical treatment plan. However, when delivery uncertainties are present, the DVH may not always accurately describe the dose distribution actually delivered to the patient. We present a method, based on DVH formalism, to visualize the variability in the expected dosimetric outcome of a treatment plan. For a case of chordoma of the cervical spine, we compared 2 intensity modulated proton therapy plans. Treatment plan A was optimized based on dosimetric objectives alone (ie, desired target coverage, normal tissue tolerance). Plan B was created employing a published probabilistic optimization method that considered the uncertainties in patient setup and proton range in tissue. Dose distributions and DVH for both plans were calculated for the nominal delivery scenario, as well as for scenarios representing deviations from the nominal setup, and a systematic error in the estimate of range in tissue. The histograms from various scenarios were combined to create DVH bands to illustrate possible deviations from the nominal plan for the expected magnitude of setup and range errors. In the nominal scenario, the DVH from plan A showed superior dose coverage, higher dose homogeneity within the target, and improved sparing of the adjacent critical structure. However, when the dose distributions and DVH from plans A and B were recalculated for different error scenarios (eg, proton range underestimation by 3 mm), the plan quality, reflected by DVH, deteriorated significantly for plan A, while plan B was only minimally affected. In the DVH-band representation, plan A produced wider bands, reflecting its higher vulnerability to delivery errors, and uncertainty in the dosimetric outcome. The results illustrate that comparison of DVH for the nominal scenario alone does not provide any information about the relative sensitivity of dosimetric outcome to delivery uncertainties. Thus, such comparison may be misleading and may result in the selection of an inferior plan for delivery to a patient. A better-informed decision can be made if additional information about possible dosimetric variability is presented; for example, in the form of DVH bands. Copyright © 2012 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.
Automatic learning-based beam angle selection for thoracic IMRT
DOE Office of Scientific and Technical Information (OSTI.GOV)
Amit, Guy; Marshall, Andrea; Purdie, Thomas G., E-mail: tom.purdie@rmp.uhn.ca
Purpose: The treatment of thoracic cancer using external beam radiation requires an optimal selection of the radiation beam directions to ensure effective coverage of the target volume and to avoid unnecessary treatment of normal healthy tissues. Intensity modulated radiation therapy (IMRT) planning is a lengthy process, which requires the planner to iterate between choosing beam angles, specifying dose–volume objectives and executing IMRT optimization. In thorax treatment planning, where there are no class solutions for beam placement, beam angle selection is performed manually, based on the planner’s clinical experience. The purpose of this work is to propose and study a computationallymore » efficient framework that utilizes machine learning to automatically select treatment beam angles. Such a framework may be helpful for reducing the overall planning workload. Methods: The authors introduce an automated beam selection method, based on learning the relationships between beam angles and anatomical features. Using a large set of clinically approved IMRT plans, a random forest regression algorithm is trained to map a multitude of anatomical features into an individual beam score. An optimization scheme is then built to select and adjust the beam angles, considering the learned interbeam dependencies. The validity and quality of the automatically selected beams evaluated using the manually selected beams from the corresponding clinical plans as the ground truth. Results: The analysis included 149 clinically approved thoracic IMRT plans. For a randomly selected test subset of 27 plans, IMRT plans were generated using automatically selected beams and compared to the clinical plans. The comparison of the predicted and the clinical beam angles demonstrated a good average correspondence between the two (angular distance 16.8° ± 10°, correlation 0.75 ± 0.2). The dose distributions of the semiautomatic and clinical plans were equivalent in terms of primary target volume coverage and organ at risk sparing and were superior over plans produced with fixed sets of common beam angles. The great majority of the automatic plans (93%) were approved as clinically acceptable by three radiation therapy specialists. Conclusions: The results demonstrated the feasibility of utilizing a learning-based approach for automatic selection of beam angles in thoracic IMRT planning. The proposed method may assist in reducing the manual planning workload, while sustaining plan quality.« less
Wang, W; Meng, Y T; Song, Y F; Sun, T; Xu, M; Shao, Q; Zhang, Y J; Li, J B
2018-05-23
Objective: To evaluated the unplanned coverage dose to the internal mammary chain (IMC) in patient treated with postmastectomy radiotherapy (PMRT). Methods: One hundred and thirty eight patients with breast cancer receiving radiotherapy (RT) in our hospital were retrospectively analyzed. Patients were divided into three groups: three-dimensional conformal radiotherapy (3D-CRT) group, forward intensity-modulated radiotherapy (F-IMRT) group and inverse IMRT (I-IMRT) group. The IMC were contoured according to Radiation Therapy Oncology Group (RTOG) consensus, and were not include into the planning target volume (PTV). The incidental irradiation dose to IMC among the three groups and the first three intercostal spaces IMC (ICS-IMC 1-3) were all compared, and explored the relationship between the mean doses (Dmean) of IMC and the OARs (ipsilateral lung and heart). Results: The dose delivered to IMC showed no difference in CRT, F-IMRT and I-IMRT(33.80 Gy, 29.65 Gy and 32.95 Gy). And 10.42%, 2.04%, and 9.76% patients achieved ≥45 Gy when treated with CRT, F-IMRT and I-IMRT. For the IMC dose in the first three intercostal spaces (ICS1-3), there was no difference to the three treatment plannings. The Dmean, V(20), V(30), V(40) and V(50) of the ICS-IMC2 and ICS-IMC3 were all obviously superior than ICS-IMC1 for all these three plannings. Moderate positive correlation was founded between Dmean for IMC and Dmean for heart for left breast cancer patients underwent CRT ( r =0.338, P =0.01). Whereas for F-IMRT and I-IMRT groups, positive correlation were founded between Dmean for IMC and Dmean and V(20) for ipsilateral lung for all patients (F-IMRT: r =0.366, P =0.010; r =0.318, P =0.026; I-IMRT: r =0.427, P =0.005; r =0.411, P =0.008). Conclusions: In 3D-CRT, F-IMRT and I-IMRT planning methods, partial patients get IMC irradiated doses that could achieve therapeutic doses. Compared with 3D-CRT, F-IMRT and I-IMRT further reduced the dose of irradiated organs. However, there is no difference in the dose coverage of IMC for the three planned approaches when the IMC made an unplanned target.
DOE Office of Scientific and Technical Information (OSTI.GOV)
An, Y; Liang, J; Liu, W
2015-06-15
Purpose: We propose to apply a probabilistic framework, namely chanceconstrained optimization, in the intensity-modulated proton therapy (IMPT) planning subject to range and patient setup uncertainties. The purpose is to hedge against the influence of uncertainties and improve robustness of treatment plans. Methods: IMPT plans were generated for a typical prostate patient. Nine dose distributions are computed — the nominal one and one each for ±5mm setup uncertainties along three cardinal axes and for ±3.5% range uncertainty. These nine dose distributions are supplied to the solver CPLEX as chance constraints to explicitly control plan robustness under these representative uncertainty scenarios withmore » certain probability. This probability is determined by the tolerance level. We make the chance-constrained model tractable by converting it to a mixed integer optimization problem. The quality of plans derived from this method is evaluated using dose-volume histogram (DVH) indices such as tumor dose homogeneity (D5% – D95%) and coverage (D95%) and normal tissue sparing like V70 of rectum, V65, and V40 of bladder. We also compare the results from this novel method with the conventional PTV-based method to further demonstrate its effectiveness Results: Our model can yield clinically acceptable plans within 50 seconds. The chance-constrained optimization produces IMPT plans with comparable target coverage, better target dose homogeneity, and better normal tissue sparing compared to the PTV-based optimization [D95% CTV: 67.9 vs 68.7 (Gy), D5% – D95% CTV: 11.9 vs 18 (Gy), V70 rectum: 0.0 % vs 0.33%, V65 bladder: 2.17% vs 9.33%, V40 bladder: 8.83% vs 21.83%]. It also simultaneously makes the plan more robust [Width of DVH band at D50%: 2.0 vs 10.0 (Gy)]. The tolerance level may be varied to control the tradeoff between plan robustness and quality. Conclusion: The chance-constrained optimization generates superior IMPT plan compared to the PTV-based optimization with explicit control of plan robustness. NIH/NCI K25CA168984, Eagles Cancer Research Career Development, The Lawrence W. and Marilyn W. Matteson Fund for Cancer Research, Mayo ASU Seed Grant, and The Kemper Marley Foundation.« less
Vaccination coverage among children in kindergarten--United States, 2009-10 school year.
2011-06-03
Healthy People 2020 objectives include maintaining vaccination coverage among children in kindergarten (IID-10) (1). The target is ≥95% vaccination coverage for the following vaccines: poliovirus; diphtheria and tetanus toxoids and acellular pertussis (DTP/DTaP/DT); measles, mumps, and rubella (MMR); hepatitis B (HepB); and varicella (1). Data from school assessment surveys are used to monitor vaccination coverage and vaccination exemption levels among children enrolled in kindergarten. This report summarizes data from school assessment surveys submitted to CDC by 48 federal immunization program grantees (including 47 states and the District of Columbia) for the 2009-10 school year to describe vaccination coverage and exemption rates (2). For that period, 17 grantees reported coverage of ?95% for four vaccines (poliovirus, DTP/DTaP/DT, MMR, and HepB) and four grantees reported coverage of ≥95% for 2 doses of varicella vaccine. Total exemption rates, including medical, religious, and philosophical exemptions, ranged from <1% to 6.2% across grantees, and 15 grantees reported exemption rates<1%. Survey methods for vaccination coverage and exemption rates varied among grantees, making comparisons difficult and limiting the use of school assessment surveys to report aggregate national rates. Further standardization of school assessment survey methods will generate comparable data between grantees to monitor and track progress in reaching national objectives, and allow development of best practice guidelines for grantees to more effectively use and report school coverage and exemption data. CDC will continue to monitor vaccination coverage and exemption levels and assist grantees in identification of local areas with low vaccination coverage or high exemption rates for further evaluation or intervention.
Kammermeier, Jochen; Drury, Suzanne; James, Chela T; Dziubak, Robert; Ocaka, Louise; Elawad, Mamoun; Beales, Philip; Lench, Nicholas; Uhlig, Holm H; Bacchelli, Chiara; Shah, Neil
2014-11-01
Multiple monogenetic conditions with partially overlapping phenotypes can present with inflammatory bowel disease (IBD)-like intestinal inflammation. With novel genotype-specific therapies emerging, establishing a molecular diagnosis is becoming increasingly important. We have introduced targeted next-generation sequencing (NGS) technology as a prospective screening tool in children with very early onset IBD (VEOIBD). We evaluated the coverage of 40 VEOIBD genes in two separate cohorts undergoing targeted gene panel sequencing (TGPS) (n=25) and whole exome sequencing (WES) (n=20). TGPS revealed causative mutations in four genes (IL10RA, EPCAM, TTC37 and SKIV2L) discovered unexpected phenotypes and directly influenced clinical decision making by supporting as well as avoiding haematopoietic stem cell transplantation. TGPS resulted in significantly higher median coverage when compared with WES, fewer coverage deficiencies and improved variant detection across established VEOIBD genes. Excluding or confirming known VEOIBD genotypes should be considered early in the disease course in all cases of therapy-refractory VEOIBD, as it can have a direct impact on patient management. To combine both described NGS technologies would compensate for the limitations of WES for disease-specific application while offering the opportunity for novel gene discovery in the research setting. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Uninsurance, underinsurance, and health care utilization in Mexico by US border residents.
Su, Dejun; Pratt, William; Stimpson, Jim P; Wong, Rebeca; Pagán, José A
2014-08-01
Using data from the 2008 Cross-Border Utilization of Health Care Survey, we examined the relationship between United States (US) health insurance coverage plans and the use of health care services in Mexico by US residents of the US-Mexico border region. We found immigrants were far more likely to be uninsured than their native-born counterparts (63 vs. 27.8 %). Adults without health insurance coverage were more likely to purchase medications or visit physicians in Mexico compared to insured adults. However, adults with Medicaid coverage were more likely to visit dentists in Mexico compared to uninsured adults. Improving health care access for US residents in the southwestern border region of the country will require initiatives that target not only providing coverage to the large uninsured population but also improving access to health care services for the large underinsured population.
Wallert, John; Tomasoni, Mattia; Madison, Guy; Held, Claes
2017-07-05
Machine learning algorithms hold potential for improved prediction of all-cause mortality in cardiovascular patients, yet have not previously been developed with high-quality population data. This study compared four popular machine learning algorithms trained on unselected, nation-wide population data from Sweden to solve the binary classification problem of predicting survival versus non-survival 2 years after first myocardial infarction (MI). This prospective national registry study for prognostic accuracy validation of predictive models used data from 51,943 complete first MI cases as registered during 6 years (2006-2011) in the national quality register SWEDEHEART/RIKS-HIA (90% coverage of all MIs in Sweden) with follow-up in the Cause of Death register (> 99% coverage). Primary outcome was AUROC (C-statistic) performance of each model on the untouched test set (40% of cases) after model development on the training set (60% of cases) with the full (39) predictor set. Model AUROCs were bootstrapped and compared, correcting the P-values for multiple comparisons with the Bonferroni method. Secondary outcomes were derived when varying sample size (1-100% of total) and predictor sets (39, 10, and 5) for each model. Analyses were repeated on 79,869 completed cases after multivariable imputation of predictors. A Support Vector Machine with a radial basis kernel developed on 39 predictors had the highest complete cases performance on the test set (AUROC = 0.845, PPV = 0.280, NPV = 0.966) outperforming Boosted C5.0 (0.845 vs. 0.841, P = 0.028) but not significantly higher than Logistic Regression or Random Forest. Models converged to the point of algorithm indifference with increased sample size and predictors. Using the top five predictors also produced good classifiers. Imputed analyses had slightly higher performance. Improved mortality prediction at hospital discharge after first MI is important for identifying high-risk individuals eligible for intensified treatment and care. All models performed accurately and similarly and because of the superior national coverage, the best model can potentially be used to better differentiate new patients, allowing for improved targeting of limited resources. Future research should focus on further model development and investigate possibilities for implementation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Girigesh, Y; Kumar, L; Raman, K
Purpose: Aim of this study is to determine the dosimetric influence of Filtered and Flatting Filter Free Photon Beam of 10 MV energy on RA planning for Ca. Cervix. Methods: CT data sets of eleven patients reported with carcinoma cervix were used for RA planning for 10MV -FFB and 10MV-FFFB. RA plans were generated using two full arcs.All RA plans were generated to deliver a dose of 50.4Gy in 28 fractions for PTV and ALARA for OAR’s. All plans were analysed for PTV Coverage, conformity Index, homogeneity index, dose to OAR’s, integral dose to normal tissue and total monitor unitsmore » were studied. Results: DVH was used to evaluate RA plans for both 10MV-FFB and 10MV-FFFB photon beam. Planning results show a comparable PTV coverage for both energies. Results shows volume of PTV receiving prescription dose were 95.10+ 0.09% and 95.09 +0.11%, and volume of PTV receiving a dose of 107% is 0.45+0.96% and 5.25+8.9%, homogeneity index (HI) were 1.051+0.007 and 1.066+0.008, Conformity Index(CI) were 1.003+0.019 and 1.012+0.013, Mean Integral dose were 2.65+0.34 and 2.60+0.33(*10−5Gy.cm3) for 10MV-FFB and 10MV-FFFB respectively. 10MV-FB shows statistically significant (p<0.05) improvement in mean doses to bladder, rectum, bowel and mean total number of MU’s and also shows remarkable decrease in mean total no. of MU’s by 43.7% in comparison to 10MV-FFFB. There is statistically significant (p<0.05) difference found in CI and HI for 10MV-FB in comparison to 10MV -FFF beam. 10MV-FFFB shows statistically significant (p<0.05) for mean NTID and delivers 1.65 % less NTID in comparison to 10 MV- FB. Conclusion: 10MV-FB is superior to 10MV-FFFB for rapid arc planning in case of Cervix carcinomas, it offers better target coverage and OAR’s sparing, comparable mean Integral dose to normal tissues and 10 MV- FB also produced highly conformal and homogeneous dose distribution in comparison to 10MV-FFFB.« less
Health-system reform and universal health coverage in Latin America.
Atun, Rifat; de Andrade, Luiz Odorico Monteiro; Almeida, Gisele; Cotlear, Daniel; Dmytraczenko, T; Frenz, Patricia; Garcia, Patrícia; Gómez-Dantés, Octavio; Knaul, Felicia M; Muntaner, Carles; de Paula, Juliana Braga; Rígoli, Felix; Serrate, Pastor Castell-Florit; Wagstaff, Adam
2015-03-28
Starting in the late 1980s, many Latin American countries began social sector reforms to alleviate poverty, reduce socioeconomic inequalities, improve health outcomes, and provide financial risk protection. In particular, starting in the 1990s, reforms aimed at strengthening health systems to reduce inequalities in health access and outcomes focused on expansion of universal health coverage, especially for poor citizens. In Latin America, health-system reforms have produced a distinct approach to universal health coverage, underpinned by the principles of equity, solidarity, and collective action to overcome social inequalities. In most of the countries studied, government financing enabled the introduction of supply-side interventions to expand insurance coverage for uninsured citizens--with defined and enlarged benefits packages--and to scale up delivery of health services. Countries such as Brazil and Cuba introduced tax-financed universal health systems. These changes were combined with demand-side interventions aimed at alleviating poverty (targeting many social determinants of health) and improving access of the most disadvantaged populations. Hence, the distinguishing features of health-system strengthening for universal health coverage and lessons from the Latin American experience are relevant for countries advancing universal health coverage. Copyright © 2015 Elsevier Ltd. All rights reserved.
State of equity: childhood immunization in the World Health Organization African Region
Casey, Rebecca Mary; Hampton, Lee McCalla; Anya, Blanche-philomene Melanga; Gacic-Dobo, Marta; Diallo, Mamadou Saliou; Wallace, Aaron Stuart
2017-01-01
Introduction In 2010, the Global Vaccine Action Plan called on all countries to reach and sustain 90% national coverage and 80% coverage in all districts for the third dose of diphtheria-tetanus-pertussis vaccine (DTP3) by 2015 and for all vaccines in national immunization schedules by 2020. The aims of this study are to analyze recent trends in national vaccination coverage in the World Health Organization African Region andto assess how these trends differ by country income category. Methods We compared national vaccination coverage estimates for DTP3 and the first dose of measles-containing vaccine (MCV) obtained from the World Health Organization (WHO)/United Nations Children’s Fund (UNICEF) joint estimates of national immunization coverage for all African Region countries. Using United Nations (UN) population estimates of surviving infants and country income category for the corresponding year, we calculated population-weighted average vaccination coverage by country income category (i.e., low, lower middle, and upper middle-income) for the years 2000, 2005, 2010 and 2015. Results DTP3 coverage in the African Region increased from 52% in 2000 to 76% in 2015,and MCV1 coverage increased from 53% to 74% during the same period, but with considerable differences among countries. Thirty-six African Region countries were low income in 2000 with an average DTP3 coverage of 50% while 26 were low income in 2015 with an average coverage of 80%. Five countries were lower middle-income in 2000 with an average DTP3 coverage of 84% while 12 were lower middle-income in 2015 with an average coverage of 69%. Five countries were upper middle-income in 2000 with an average DTP3 coverage of 73% and eight were upper middle-income in 2015 with an average coverage of 76%. Conclusion Disparities in vaccination coverage by country persist in the African Region, with countries that were lower middle-income having the lowest coverage on average in 2015. Monitoring and addressing these disparities is essential for meeting global immunization targets. PMID:29296140
Phoummalaysith, Bounfeng; Yamamoto, Eiko; Xeuatvongsa, Anonh; Louangpradith, Viengsakhone; Keohavong, Bounxou; Saw, Yu Mon; Hamajima, Nobuyuki
2018-05-03
Routine vaccination is administered free of charge to all children under one year old in Lao People's Democratic Republic (Lao PDR) and the national goal is to achieve at least 95% coverage with all vaccines included in the national immunization program by 2025. In this study, factors related to the immunization system and characteristics of provinces and districts in Lao PDR were examined to evaluate the association with routine immunization coverage. Coverage rates for Bacillus Calmette-Guerin (BCG), Diphtheria-Tetanus-Pertussis-Hepatitis B (DTP-HepB), DTP-HepB-Hib (Haemophilus influenzae type B), polio (OPV), and measles (MCV1) vaccines from 2002 to 2014 collected through regular reporting system, were used to identify the immunization coverage trends in Lao PDR. Correlation analysis was performed using immunization coverage, characteristics of provinces or districts (population, population density, and proportion of poor villages and high-risk villages), and factors related to immunization service (including the proportions of the following: villages served by health facility levels, vaccine session types, and presence of well-functioning cold chain equipment). To determine factors associated with low coverage, provinces were categorized based on 80% of DTP-HepB-Hib3 coverage (<80% = low group; ≥80% = high group). Coverages of BCG, DTP-HepB3, OPV3 and MCV1 increased gradually from 2007 to 2014 (82.2-88.3% in 2014). However, BCG coverage showed the least improvement from 2002 to 2014. The coverage of each vaccine correlated with the coverage of the other vaccines and DTP-HepB-Hib dropout rate in provinces as well as districts. The provinces with low immunization coverage were correlated with higher proportions of poor villages. Routine immunization coverage has been improving in the last 13 years, but the national goal is not yet reached in Lao PDR. The results of this study suggest that BCG coverage and poor villages should be targeted to improve nationwide coverage. Copyright © 2018 Elsevier Ltd. All rights reserved.
Leyvraz, Magali; Rohner, Fabian; Konan, Amoin G; Esso, Lasme J C E; Woodruff, Bradley A; Norte, Augusto; Adiko, Adiko F; Bonfoh, Bassirou; Aaron, Grant J
2016-01-01
Poor complementary feeding practices among infants and young children in Côte d'Ivoire are major contributing factors to the country's high burden of malnutrition. As part of a broad effort to address this issue, an affordable, nutritious, and locally produced fortified complementary food product was launched in the Côte d'Ivoire in 2011. The objective of the current research was to assess various levels of coverage of the program and to identify coverage barriers. A cross-sectional household survey was conducted among caregivers of children less than 2-years of age living in Abidjan, Côte d'Ivoire. Four measures of coverage were assessed: "message coverage" (i.e., has the caregiver ever heard of the product?), "contact coverage" (i.e., has the caregiver ever fed the child the product?), "partial coverage" (i.e., has the caregiver fed the child the product in the previous month?), and "effective coverage" (i.e., has the caregiver fed the child the product in the previous 7 days?). A total of 1,113 caregivers with children between 0 and 23 months of age were interviewed. Results showed high message coverage (85.0%), moderate contact coverage (37.8%), and poor partial and effective coverages (8.8% and 4.6%, respectively). Product awareness was lower among caregivers from poorer households, but partial and effective coverages were comparable in both poor and non-poor groups. Infant and young child feeding (IYCF) practices were generally poor and did not appear to have improved since previous assessments. In conclusion, the results from the present study indicate that availability on the market and high awareness among the target population is not sufficient to achieve high and effective coverage. With market-based delivery models, significant efforts are needed to improve demand. Moreover, given the high prevalence of malnutrition and poor IYCF practices, additional modes of delivering IYCF interventions and improving IYCF practices should be considered.
Highly multiplexed targeted DNA sequencing from single nuclei.
Leung, Marco L; Wang, Yong; Kim, Charissa; Gao, Ruli; Jiang, Jerry; Sei, Emi; Navin, Nicholas E
2016-02-01
Single-cell DNA sequencing methods are challenged by poor physical coverage, high technical error rates and low throughput. To address these issues, we developed a single-cell DNA sequencing protocol that combines flow-sorting of single nuclei, time-limited multiple-displacement amplification (MDA), low-input library preparation, DNA barcoding, targeted capture and next-generation sequencing (NGS). This approach represents a major improvement over our previous single nucleus sequencing (SNS) Nature Protocols paper in terms of generating higher-coverage data (>90%), thereby enabling the detection of genome-wide variants in single mammalian cells at base-pair resolution. Furthermore, by pooling 48-96 single-cell libraries together for targeted capture, this approach can be used to sequence many single-cell libraries in parallel in a single reaction. This protocol greatly reduces the cost of single-cell DNA sequencing, and it can be completed in 5-6 d by advanced users. This single-cell DNA sequencing protocol has broad applications for studying rare cells and complex populations in diverse fields of biological research and medicine.
Objective sea level pressure analysis for sparse data areas
NASA Technical Reports Server (NTRS)
Druyan, L. M.
1972-01-01
A computer procedure was used to analyze the pressure distribution over the North Pacific Ocean for eleven synoptic times in February, 1967. Independent knowledge of the central pressures of lows is shown to reduce the analysis errors for very sparse data coverage. The application of planned remote sensing of sea-level wind speeds is shown to make a significant contribution to the quality of the analysis especially in the high gradient mid-latitudes and for sparse coverage of conventional observations (such as over Southern Hemisphere oceans). Uniform distribution of the available observations of sea-level pressure and wind velocity yields results far superior to those derived from a random distribution. A generalization of the results indicates that the average lower limit for analysis errors is between 2 and 2.5 mb based on the perfect specification of the magnitude of the sea-level pressure gradient from a known verification analysis. A less than perfect specification will derive from wind-pressure relationships applied to satellite observed wind speeds.
Lindsey, Rebecca L.; Pouseele, Hannes; Chen, Jessica C.; Strockbine, Nancy A.; Carleton, Heather A.
2016-01-01
Shiga toxin-producing Escherichia coli (STEC) is an important foodborne pathogen capable of causing severe disease in humans. Rapid and accurate identification and characterization techniques are essential during outbreak investigations. Current methods for characterization of STEC are expensive and time-consuming. With the advent of rapid and cheap whole genome sequencing (WGS) benchtop sequencers, the potential exists to replace traditional workflows with WGS. The aim of this study was to validate tools to do reference identification and characterization from WGS for STEC in a single workflow within an easy to use commercially available software platform. Publically available serotype, virulence, and antimicrobial resistance databases were downloaded from the Center for Genomic Epidemiology (CGE) (www.genomicepidemiology.org) and integrated into a genotyping plug-in with in silico PCR tools to confirm some of the virulence genes detected from WGS data. Additionally, down sampling experiments on the WGS sequence data were performed to determine a threshold for sequence coverage needed to accurately predict serotype and virulence genes using the established workflow. The serotype database was tested on a total of 228 genomes and correctly predicted from WGS for 96.1% of O serogroups and 96.5% of H serogroups identified by conventional testing techniques. A total of 59 genomes were evaluated to determine the threshold of coverage to detect the different WGS targets, 40 were evaluated for serotype and virulence gene detection and 19 for the stx gene subtypes. For serotype, 95% of the O and 100% of the H serogroups were detected at > 40x and ≥ 30x coverage, respectively. For virulence targets and stx gene subtypes, nearly all genes were detected at > 40x, though some targets were 100% detectable from genomes with coverage ≥20x. The resistance detection tool was 97% concordant with phenotypic testing results. With isolates sequenced to > 40x coverage, the different databases accurately predicted serotype, virulence, and resistance from WGS data, providing a fast and cheaper alternative to conventional typing techniques. PMID:27242777
van de Schoot, Agustinus J A J; de Boer, Peter; Visser, Jorrit; Stalpers, Lukas J A; Rasch, Coen R N; Bel, Arjan
2017-05-01
Radiation therapy (RT) using a daily plan selection adaptive strategy can be applied to account for interfraction organ motion while limiting organ at risk dose. The aim of this study was to quantify the dosimetric consequences of daily plan selection compared with non-adaptive RT in cervical cancer. Ten consecutive patients who received pelvic irradiation, planning CTs (full and empty bladder), weekly post-fraction CTs and pre-fraction CBCTs were included. Non-adaptive plans were generated based on the PTV defined using the full bladder planning CT. For the adaptive strategy, multiple PTVs were created based on both planning CTs by ITVs of the primary CTVs (i.e., GTV, cervix, corpus-uterus and upper part of the vagina) and corresponding library plans were generated. Daily CBCTs were rigidly aligned to the full bladder planning CT for plan selection. For daily plan recalculation, selected CTs based on initial similarity were deformably registered to CBCTs. Differences in daily target coverage (D 98% > 95%) and in V 0.5Gy , V 1.5Gy , V 2Gy , D 50% and D 2% for rectum, bladder and bowel were assessed. Non-adaptive RT showed inadequate primary CTV coverage in 17% of the daily fractions. Plan selection compensated for anatomical changes and improved primary CTV coverage significantly (p < 0.01) to 98%. Compared with non-adaptive RT, plan selection decreased the fraction dose to rectum and bowel indicated by significant (p < 0.01) improvements for daily V 0.5Gy , V 1.5Gy , V 2Gy , D 50% and D 2% . However, daily plan selection significantly increased the bladder V 1.5Gy , V 2Gy , D 50% and D 2% . In cervical cancer RT, a non-adaptive strategy led to inadequate target coverage for individual patients. Daily plan selection corrected for day-to-day anatomical variations and resulted in adequate target coverage in all fractions. The dose to bowel and rectum was decreased significantly when applying adaptive RT.
Lindsey, Rebecca L; Pouseele, Hannes; Chen, Jessica C; Strockbine, Nancy A; Carleton, Heather A
2016-01-01
Shiga toxin-producing Escherichia coli (STEC) is an important foodborne pathogen capable of causing severe disease in humans. Rapid and accurate identification and characterization techniques are essential during outbreak investigations. Current methods for characterization of STEC are expensive and time-consuming. With the advent of rapid and cheap whole genome sequencing (WGS) benchtop sequencers, the potential exists to replace traditional workflows with WGS. The aim of this study was to validate tools to do reference identification and characterization from WGS for STEC in a single workflow within an easy to use commercially available software platform. Publically available serotype, virulence, and antimicrobial resistance databases were downloaded from the Center for Genomic Epidemiology (CGE) (www.genomicepidemiology.org) and integrated into a genotyping plug-in with in silico PCR tools to confirm some of the virulence genes detected from WGS data. Additionally, down sampling experiments on the WGS sequence data were performed to determine a threshold for sequence coverage needed to accurately predict serotype and virulence genes using the established workflow. The serotype database was tested on a total of 228 genomes and correctly predicted from WGS for 96.1% of O serogroups and 96.5% of H serogroups identified by conventional testing techniques. A total of 59 genomes were evaluated to determine the threshold of coverage to detect the different WGS targets, 40 were evaluated for serotype and virulence gene detection and 19 for the stx gene subtypes. For serotype, 95% of the O and 100% of the H serogroups were detected at > 40x and ≥ 30x coverage, respectively. For virulence targets and stx gene subtypes, nearly all genes were detected at > 40x, though some targets were 100% detectable from genomes with coverage ≥20x. The resistance detection tool was 97% concordant with phenotypic testing results. With isolates sequenced to > 40x coverage, the different databases accurately predicted serotype, virulence, and resistance from WGS data, providing a fast and cheaper alternative to conventional typing techniques.
A needle in a haystack? Uninsured workers in small businesses that do not offer coverage.
Kronick, Richard; Olsen, Louis C
2006-02-01
To describe the insurance status of workers at small businesses, and to describe the status of uninsured persons by the employment characteristics (employment status, firm size, and whether the employer offers insurance) of the head of household. Data from the March and February 2001 Current Population Survey, and a survey of 2,830 small businesses in San Diego County conducted in 2001. The survey of small businesses was undertaken as part of a project testing the response of employers to offers of subsidized coverage. Employers were asked whether they offered insurance, and about the insurance status of their employees. The merged February-March 2001 CPS was used to identify the employment status, firm size, and employer-offering status for uninsured persons in the U.S. Telephone interviews with small businesses in San Diego County. Only 21 percent of the uninsured in the U.S. are full-time employees (or their dependents) in small businesses (<100 employees) that do not offer insurance. The employment status of the uninsured is heterogeneous: many work for large employers, small employers who do offer insurance, or are self-employed, part-time workers, or have no workers in the household. Although there are many small businesses in San Diego that do not offer coverage, most of them have very few uninsured workers. Over 50 percent of businesses that do not offer coverage have either zero or one uninsured worker. There are very few small businesses that do not offer coverage and that have substantial numbers of uninsured workers. These businesses are not quite as rare as a needle in a haystack, but they are very difficult to find. If all small businesses that do not offer insurance now could be persuaded to start offering coverage, and if all the full-time workers (and their dependents) in those businesses accepted insurance, the number of uninsured would decline by 21 percent--a significant decline, but leaving 80 percent of the problem untouched. If the prime target for programs of subsidized insurance are small businesses that do not offer coverage now and that have substantial numbers of uninsured workers, the target is very small.
Cluster Survey Evaluation of a Measles Vaccination Campaign in Jharkhand, India, 2012
Scobie, Heather M.; Ray, Arindam; Routray, Satyabrata; Bose, Anindya; Bahl, Sunil; Sosler, Stephen; Wannemuehler, Kathleen; Kumar, Rakesh; Haldar, Pradeep; Anand, Abhijeet
2015-01-01
Introduction India was the last country in the world to implement a two-dose strategy for measles-containing vaccine (MCV) in 2010. As part of measles second-dose introduction, phased measles vaccination campaigns were conducted during 2010–2013, targeting 131 million children 9 months to <10 years of age. We performed a post-campaign coverage survey to estimate measles vaccination coverage in Jharkhand state. Methods A multi-stage cluster survey was conducted 2 months after the phase 2 measles campaign occurred in 19 of 24 districts of Jharkhand during November 2011–March 2012. Vaccination status of children 9 months to <10 years of age was documented based on vaccination card or mother’s recall. Coverage estimates and 95% confidence intervals (95% CI) for 1,018 children were calculated using survey methods. Results In the Jharkhand phase 2 campaign, MCV coverage among children aged 9 months to <10 years was 61.0% (95% CI: 54.4–67.7%). Significant differences in coverage were observed between rural (65.0%; 95% CI: 56.8–73.2%) and urban areas (45.6%; 95% CI: 37.3–53.9%). Campaign awareness among mothers was low (51.5%), and the most commonly reported reason for non-vaccination was being unaware of the campaign (69.4%). At the end of the campaign, 53.7% (95% CI: 46.5–60.9%) of children 12 months to <10 years of age received ≥2 MCV doses, while a large proportion of children remained under-vaccinated (34.0%, 95% CI: 28.0–40.0%) or unvaccinated (12.3%, 95% CI: 9.3–16.2%). Conclusions Implementation of the national measles campaign was a significant achievement towards measles elimination in India. In Jharkhand, campaign performance was below the target coverage of ≥90% set by the Government of India, and challenges in disseminating campaign messages were identified. Efforts towards increasing two-dose MCV coverage are needed to achieve the recently adopted measles elimination goal in India and the South-East Asia region. PMID:26010084
Gandhi, Saumil J; Liang, Xing; Ding, Xuanfeng; Zhu, Timothy C; Ben-Josef, Edgar; Plastaras, John P; Metz, James M; Both, Stefan; Apisarnthanarax, Smith
2015-01-01
Stereotactic body radiation therapy (SBRT) for treatment of liver tumors is often limited by liver dose constraints. Protons offer potential for more liver sparing, but clinical situations in which protons may be superior to photons are not well described. We developed and validated a treatment decision model to determine whether liver tumors of certain sizes and locations are more suited for photon versus proton SBRT. Six spherical mock tumors from 1 to 6 cm in diameter were contoured on computed tomography images of 1 patient at 4 locations: dome, caudal, left medial, and central. Photon and proton plans were generated to deliver 50 Gy in 5 fractions to each tumor and optimized to deliver equivalent target coverage and maximal liver sparing. Using these plans, we developed a hypothesis-generating model to predict the optimal modality for maximal liver sparing based on tumor size and location. We then validated this model in 10 patients with liver tumors. Protons spared significantly more liver than photons for dome or central tumors ≥3 cm (dome: 134 ± 21 cm(3), P = .03; central: 108 ± 4 cm(3), P = .01). Our model correctly predicted the optimal SBRT modality for all 10 patients. For patients with dome or central tumors ≥3 cm, protons significantly increased the volume of liver spared (176 ± 21 cm(3), P = .01) and decreased the mean liver dose (8.4 vs 12.2 Gy, P = .01) while offering no significant advantage for tumors <3 cm at any location or for caudal and left medial tumors of any size. When feasible, protons should be considered as the radiation modality of choice for dome and central tumors >3 cm to allow maximal liver sparing and potentially reduce radiation toxicity. Protons should also be considered for any tumor >5 cm if photon plans fail to achieve adequate coverage or exceed the mean liver threshold. Copyright © 2015 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.
Direct plan comparison of RapidArc and CyberKnife for spine stereotactic body radiation therapy
NASA Astrophysics Data System (ADS)
Choi, Young Eun; Kwak, Jungwon; Song, Si Yeol; Choi, Eun Kyung; Ahn, Seung Do; Cho, Byungchul
2015-07-01
We compared the treatment planning performance of RapidArc (RA) vs. CyberKnife (CK) for spinal stereotactic body radiation therapy (SBRT). Ten patients with spinal lesions who had been treated with CK were re-planned with RA, which consisted of two complete arcs. Computed tomography (CT) and volumetric dose data of CK, generated using the Multiplan (Accuray) treatment planning system (TPS) and the Ray-trace algorithm, were imported to Varian Eclipse TPS in Dicom format, and the data were compared with the RA plan by using an analytical anisotropic algorithm (AAA) dose calculation. The optimized dose priorities for both the CK and the RA plans were similar for all patients. The highest priority was to provide enough dose coverage to the planned target volume (PTV) while limiting the maximum dose to the spinal cord. Plan quality was evaluated with respect to PTV coverage, conformity index (CI), high-dose spillage, intermediate-dose spillage (R50% and D2cm), and maximum dose to the spinal cord, which are criteria recommended by the RTOG 0631 spine and 0915 lung SBRT protocols. The mean CI' SD values of the PTV were 1.11' 0.03 and 1.17' 0.10 for RA and CK ( p = 0.02), respectively. On average, the maximum dose delivered to the spinal cord in CK plans was approximately 11.6% higher than that in RA plans, and this difference was statistically significant ( p < 0.001). High-dose spillages were 0.86% and 2.26% for RA and CK ( p = 0.203), respectively. Intermediate-dose spillage characterized by D2cm was lower for RA than for CK; however, R50% was not statistically different. Even though both systems can create highly conformal volumetric dose distributions, the current study shows that RA demonstrates lower high- and intermediate-dose spillages than CK. Therefore, RA plans for spinal SBRT may be superior to CK plans.
Lee, T-F; Ting, H-M; Chao, P-J; Wang, H-Y; Shieh, C-S; Horng, M-F; Wu, J-M; Yeh, S-A; Cho, M-Y; Huang, E-Y; Huang, Y-J; Chen, H-C; Fang, F-M
2012-01-01
Objective We compared and evaluated the differences between two models for treating bilateral breast cancer (BBC): (i) dose–volume-based intensity-modulated radiation treatment (DV plan), and (ii) dose–volume-based intensity-modulated radiotherapy with generalised equivalent uniform dose-based optimisation (DV-gEUD plan). Methods The quality and performance of the DV plan and DV-gEUD plan using the Pinnacle3® system (Philips, Fitchburg, WI) were evaluated and compared in 10 patients with stage T2–T4 BBC. The plans were delivered on a Varian 21EX linear accelerator (Varian Medical Systems, Milpitas, CA) equipped with a Millennium 120 leaf multileaf collimator (Varian Medical Systems). The parameters analysed included the conformity index, homogeneity index, tumour control probability of the planning target volume (PTV), the volumes V20 Gy and V30 Gy of the organs at risk (OAR, including the heart and lungs), mean dose and the normal tissue complication probability. Results Both plans met the requirements for the coverage of PTV with similar conformity and homogeneity indices. However, the DV-gEUD plan had the advantage of dose sparing for OAR: the mean doses of the heart and lungs, lung V20 Gy, and heart V30 Gy in the DV-gEUD plan were lower than those in the DV plan (p<0.05). Conclusions A better result can be obtained by starting with a DV-generated plan and then improving it by adding gEUD-based improvements to reduce the number of iterations and to improve the optimum dose distribution. Advances to knowledge The DV-gEUD plan provided superior dosimetric results for treating BBC in terms of PTV coverage and OAR sparing than the DV plan, without sacrificing the homogeneity of dose distribution in the PTV. PMID:23091290
SU-G-BRC-04: Collimator Angle Optimization in Volumetric Modulated Arc Therapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Andersen, A; Johnson, C; Bartlett, G
2016-06-15
Purpose: Volumetric modulated arc therapy (VMAT) has revolutionized radiation treatment by decreasing treatment time and monitor units, thus reducing scattered and whole body radiation dose. As the collimator angle changes the apparent leaf gap becomes larger which can impact plan quality, organ at risk (OAR) sparing as well as IMRT QA passing rate which is investigated. Methods: Two sites (prostate and head and neck) that have maximum utilization of VMAT were investigated. Two previously treated VMAT patients were chosen. For each patient 10 plans were created by maintaining constant optimization constraints while varying collimator angles from 0-90 deg at anmore » interval of 10 degrees for the first arc and the appropriate complimentary angle for the second arc. Plans were created with AAA algorithm using 6 MV beam on a Varian IX machine with Millennium 120 MLC. The dose-volume histogram (DVH) for each plan was exported and dosimetric parameters (D98, D95, D50, D2) as well homogeneity index (HI) and conformity index (CI) were computed. Each plan was validated for QA using ArcCheck with gamma index passing criteria of 2%/2 mm and 3%/3 mm. Additionally, normal tissue complication probability (NTCP) for each OAR was computed using Uzan-Nahum software. Results: The CI values for both sites had no impact as target volume coverage in every collimator angle were the same since it was optimized for adequate coverage. The HI which is representative of DVH gradient or dose uniformity in PTV showed a clear trend in both sites. The NTCP for OAR (brain and cochlea) in H&N plan and (bladder and rectum) in prostate plan showed a distinct superiority for collimator angles between 15-30 deg. The gamma passing rates were not correlated with angle. Conclusion: Based on CI, HI, NTCP and gamma passing index, it can be concluded that collimator angles should be maintained within 15–30 deg.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gibson, Eli; Biomedical Engineering, University of Western Ontario, London, Ontario; Centre for Medical Image Computing, University College London, London
Purpose: Defining prostate cancer (PCa) lesion clinical target volumes (CTVs) for multiparametric magnetic resonance imaging (mpMRI) could support focal boosting or treatment to improve outcomes or lower morbidity, necessitating appropriate CTV margins for mpMRI-defined gross tumor volumes (GTVs). This study aimed to identify CTV margins yielding 95% coverage of PCa tumors for prospective cases with high likelihood. Methods and Materials: Twenty-five men with biopsy-confirmed clinical stage T1 or T2 PCa underwent pre-prostatectomy mpMRI, yielding T2-weighted, dynamic contrast-enhanced, and apparent diffusion coefficient images. Digitized whole-mount histology was contoured and registered to mpMRI scans (error ≤2 mm). Four observers contoured lesion GTVs onmore » each mpMRI scan. CTVs were defined by isotropic and anisotropic expansion from these GTVs and from multiparametric (unioned) GTVs from 2 to 3 scans. Histologic coverage (proportions of tumor area on co-registered histology inside the CTV, measured for Gleason scores [GSs] ≥6 and ≥7) and prostate sparing (proportions of prostate volume outside the CTV) were measured. Nonparametric histologic-coverage prediction intervals defined minimal margins yielding 95% coverage for prospective cases with 78% to 92% likelihood. Results: On analysis of 72 true-positive tumor detections, 95% coverage margins were 9 to 11 mm (GS ≥ 6) and 8 to 10 mm (GS ≥ 7) for single-sequence GTVs and were 8 mm (GS ≥ 6) and 6 mm (GS ≥ 7) for 3-sequence GTVs, yielding CTVs that spared 47% to 81% of prostate tissue for the majority of tumors. Inclusion of T2-weighted contours increased sparing for multiparametric CTVs with 95% coverage margins for GS ≥6, and inclusion of dynamic contrast-enhanced contours increased sparing for GS ≥7. Anisotropic 95% coverage margins increased the sparing proportions to 71% to 86%. Conclusions: Multiparametric magnetic resonance imaging–defined GTVs expanded by appropriate margins may support focal boosting or treatment of PCa; however, these margins, accounting for interobserver and intertumoral variability, may preclude highly conformal CTVs. Multiparametric GTVs and anisotropic margins may reduce the required margins and improve prostate sparing.« less
A risk-based coverage model for video surveillance camera control optimization
NASA Astrophysics Data System (ADS)
Zhang, Hongzhou; Du, Zhiguo; Zhao, Xingtao; Li, Peiyue; Li, Dehua
2015-12-01
Visual surveillance system for law enforcement or police case investigation is different from traditional application, for it is designed to monitor pedestrians, vehicles or potential accidents. Visual surveillance risk is defined as uncertainty of visual information of targets and events monitored in present work and risk entropy is introduced to modeling the requirement of police surveillance task on quality and quantity of vide information. the prosed coverage model is applied to calculate the preset FoV position of PTZ camera.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cheon, G; Kang, Y; Kang, S
Purpose: Hippocampus is one of the important organs which controls emotions, behaviors, movements the memorizing and learning ability. In the conventional head & neck therapy position, it is difficult to perform the hippocampal-sparing brain radiation therapy. The purpose of this study is to investigate optimal head angle which can save the hippocampal-sparing and organ at risk (OAR) in conformal radiation therapy (CRT), Intensity modulation radiation therapy (IMRT) and helical tomotherapy (HT). Methods: Three types of radiation treatment plans, CRT, IMRT and Tomotherapy plans, were performed for 10 brain tumor patients. The image fusion between CT and MRI data were usedmore » in the contour due to the limited delineation of the target and OAR in the CT scan. The optimal condition plan was determined by comparing the dosimetric performance of the each plan with the use of various parameters which include three different techniques (CRT, IMRT, HT) and 4 angle (0, 15, 30, 40 degree). The each treatment plans of three different techniques were compared with the following parameters: conformity index (CI), homogeneity index (HI), target coverage, dose in the OARs, monitor units (MU), beam on time and the normal tissue complication probability (NTCP). Results: HI, CI and target coverage was most excellent in head angle 30 degree among all angle. When compared by modality, target coverage and CI showed good results in IMRT and TOMO than compared to the CRT. HI at the head angle 0 degrees is 1.137±0.17 (CRT), 1.085±0.09 (IMRT) and 1.077±0.06 (HT). HI at the head angle 30 degrees is 1.056±0.08 (CRT), 1.020±0.05 (IMRT) and 1.022±0.07 (HT). Conclusion: The results of our study show that when head angle tilted at 30 degree, target coverage, HI, CI were improved, and the dose delivered to OAR was reduced compared with conventional supine position in brain radiation therapy. This work was supported by the Radiation Technology R&D program (No. 2013M2A2A7043498) and the Mid-career Researcher Program (2014R1A2A1A10050270) through the National Research Foundation of Korea funded by the Ministry of Science, ICT&Future Planning.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Moignier, A; Gelover, E; Wang, D
Purpose: A dynamic collimation system (DCS) based on two orthogonal pairs of mobile trimmer blades has recently been proposed to reduce the lateral penumbra in spot scanning proton therapy (SSPT). The purpose of this work is to quantify the therapeutic benefit of using the DCS for SSPT of brain cancer by comparing un-collimated and collimated treatment plans. Methods: Un-collimated and collimated brain treatment plans were created for five patients, previously treated with SSPT, using an in-house treatment planning system capable of modeling collimated and un-collimated beamlets. Un-collimated plans reproduced the clinically delivered plans in terms of target coverage and organ-at-riskmore » (OAR) sparing, whereas collimated plans were re-optimized to improve the organ-at-risk sparing while maintaining target coverage. Physical and biological comparison metrics such as dose distribution conformity, mean and maximum doses, normal tissue complication probability (NTCP) and risk of secondary brain cancer were used to evaluate the plans. Results: The DCS systematically improved the dose distribution conformity while preserving the target coverage. The average reduction of the mean dose to the 10-mm ring surrounding the target and the healthy brain were 7.1% (95% CI: 4.2%–9.9%; p<0.01) and 14.3% (95% CI: 7.8%–20.8%; p<0.01), respectively. This yielded an average reduction of 12.0% (95% CI: 8.2%–15.7%; p<0.01) for the brain necrosis NTCP using the Flickinger model, and 14.2% (95% CI: 7.7%–20.8%; p<0.01) for the risk of secondary brain cancer. The average maximum dose reductions for the brainstem, chiasm, optic nerves, cochleae and pituitary gland when comparing un-collimated and collimated plans were 14.3%, 10.4%, 11.2%, 13.0%, 12.9% and 3.4%, respectively. Evaluating individual plans using the Lyman-Kutcher-Burman NTCP model also yielded improvements. Conclusion: The lateral penumbra reduction performed by the DCS increases the normal tissue sparing capabilities of SSPT for brain tumor treatment while preserving the target coverage. This research was financially supported by Ion Beam Applications S.A. (IBA, Louvain-La-Neuve, Belgium)« less
Böhmer, Merle M; Walter, Dietmar; Falkenhorst, Gerhard; Müters, Stephan; Krause, Gérard; Wichmann, Ole
2012-10-31
In Germany, annual vaccination against seasonal influenza is recommended for certain target groups (e.g. persons aged ≥60 years, chronically ill persons, healthcare workers (HCW)). In season 2009/10, vaccination against pandemic influenza A(H1N1)pdm09, which was controversially discussed in the public, was recommended for the whole population. The objectives of this study were to assess vaccination coverage for seasonal (seasons 2008/09-2010/11) and pandemic influenza (season 2009/10), to identify predictors of and barriers to pandemic vaccine uptake and whether the controversial discussions on pandemic vaccination has had a negative impact on seasonal influenza vaccine uptake in Germany. We analysed data from the 'German Health Update' (GEDA10) telephone survey (n=22,050) and a smaller GEDA10-follow-up survey (n=2,493), which were both representative of the general population aged ≥18 years living in Germany. Overall only 8.8% of the adult population in Germany received a vaccination against pandemic influenza. High socioeconomic status, having received a seasonal influenza shot in the previous season, and belonging to a target group for seasonal influenza vaccination were independently associated with the uptake of pandemic vaccines. The main reasons for not receiving a pandemic vaccination were 'fear of side effects' and the opinion that 'vaccination was not necessary'. Seasonal influenza vaccine uptake in the pre-pandemic season 2008/09 was 52.8% among persons aged ≥60 years; 30.5% among HCW, and 43.3% among chronically ill persons. A decrease in vaccination coverage was observed across all target groups in the first post-pandemic season 2010/11 (50.6%, 25.8%, and 41.0% vaccination coverage, respectively). Seasonal influenza vaccination coverage in Germany remains in all target groups below 75%, which is a declared goal of the European Union. Our results suggest that controversial public discussions about safety and the benefits of pandemic influenza vaccination may have contributed to both a very low uptake of pandemic vaccines and a decreased uptake of seasonal influenza vaccines in the first post-pandemic season. In the upcoming years, the uptake of seasonal influenza vaccines should be carefully monitored in all target groups to identify if this trend continues and to guide public health authorities in developing more effective vaccination and communication strategies for seasonal influenza vaccination.
Mae, Naomi; Ode, Hirotaka; Nemoto, Manabu; Tsujimura, Koji; Yamanaka, Takashi; Kondo, Takashi; Matsumura, Tomio
2014-01-01
Equine herpesvirus type 1 (EHV-1) is a major cause of winter pyrexia in racehorses in two training centers (Ritto and Miho) in Japan. Until the epizootic period of 2008-2009, a vaccination program using a killed EHV-1 vaccine targeted only susceptible 3-year-old horses with low antibody levels to EHV-1 antigens. However, because the protective effect was not satisfactory, in 2009-2010 the vaccination program was altered to target all 3-year-old horses. To evaluate the vaccine's efficacy, we investigated the number of horses with pyrexia due to EHV-1 or equine herpesvirus type 4 (EHV-4) infection or both and examined the vaccination coverage in the 3-year-old population and in the whole population before and after changes in the program. The mean (± standard deviation [SD]) estimated numbers of horses infected with EHV-1 or EHV-4 or both, among pyretic horses from 1999-2000 to 2008-2009 were 105 ± 47 at Ritto and 66 ± 44 at Miho. Although the estimated number of infected horses did not change greatly in the first period of the current program, it decreased from the second period, with means (±SD) of 21 ± 12 at Ritto and 14 ± 15 at Miho from 2010-2011 to 2012-2013. Vaccination coverage in the 3-year-old population was 99.4% at Ritto and 99.8% at Miho in the first period, and similar values were maintained thereafter. Coverage in the whole population increased more gradually than that in the 3-year-old population. The results suggest that EHV-1 epizootics can be suppressed by maintaining high vaccination coverage, not only in the 3-year-old population but also in the whole population. PMID:24872513
Did the dependent coverage expansion increase risky substance use among young adults?
Breslau, Joshua; Yu, Hao; Han, Bing; Pacula, Rosalie L; Burns, Rachel M; Stein, Bradley D
2017-09-01
The dependent coverage expansion (DCE) enacted through the Affordable Care Act increased health insurance coverage among young adults. Increasing insurance coverage in this age group has the potential for unintended consequences on risky substance use. Repeated cross-sectional surveys were used to compare change in substance use during the period the DCE was implemented in the 19-25year old target age group (Pre-DCE n=15,772, Post-DCE n=22,719) with contemporaneous change in a slightly older age group that was not targeted by the policy (Pre-DCE=19,851, Post-DCE n=28,157). Outcomes include 11 measures of alcohol, illicit drug and cigarette use. Statistical controls were included for demographic and socioeconomic factors and for early initiation of substance use to adjust for historical trends in developmental trajectories. Risky substance use decreased in young adults relative to the older age group over the period that the DCE was implemented. However, statistical adjustment for initiation of substance use prior to age 18, which is prior to exposure to the DCE, accounted for the differences between the age groups. In adjusted models, associations between the DCE and substance use outcomes range from 0.96 to 1.08 with p-values ranging from 0.330 to 0.963. Historical trends in initiation of substance use prior to age 18, not the DCE, account for change in risky substance use among 19-25year olds relative to 26-34year olds. The evidence does not support the suggestion that health insurance coverage would increase risky substance use among young adults. Copyright © 2017 Elsevier B.V. All rights reserved.
MCMC-ODPR: primer design optimization using Markov Chain Monte Carlo sampling.
Kitchen, James L; Moore, Jonathan D; Palmer, Sarah A; Allaby, Robin G
2012-11-05
Next generation sequencing technologies often require numerous primer designs that require good target coverage that can be financially costly. We aimed to develop a system that would implement primer reuse to design degenerate primers that could be designed around SNPs, thus find the fewest necessary primers and the lowest cost whilst maintaining an acceptable coverage and provide a cost effective solution. We have implemented Metropolis-Hastings Markov Chain Monte Carlo for optimizing primer reuse. We call it the Markov Chain Monte Carlo Optimized Degenerate Primer Reuse (MCMC-ODPR) algorithm. After repeating the program 1020 times to assess the variance, an average of 17.14% fewer primers were found to be necessary using MCMC-ODPR for an equivalent coverage without implementing primer reuse. The algorithm was able to reuse primers up to five times. We compared MCMC-ODPR with single sequence primer design programs Primer3 and Primer-BLAST and achieved a lower primer cost per amplicon base covered of 0.21 and 0.19 and 0.18 primer nucleotides on three separate gene sequences, respectively. With multiple sequences, MCMC-ODPR achieved a lower cost per base covered of 0.19 than programs BatchPrimer3 and PAMPS, which achieved 0.25 and 0.64 primer nucleotides, respectively. MCMC-ODPR is a useful tool for designing primers at various melting temperatures at good target coverage. By combining degeneracy with optimal primer reuse the user may increase coverage of sequences amplified by the designed primers at significantly lower costs. Our analyses showed that overall MCMC-ODPR outperformed the other primer-design programs in our study in terms of cost per covered base.
MCMC-ODPR: Primer design optimization using Markov Chain Monte Carlo sampling
2012-01-01
Background Next generation sequencing technologies often require numerous primer designs that require good target coverage that can be financially costly. We aimed to develop a system that would implement primer reuse to design degenerate primers that could be designed around SNPs, thus find the fewest necessary primers and the lowest cost whilst maintaining an acceptable coverage and provide a cost effective solution. We have implemented Metropolis-Hastings Markov Chain Monte Carlo for optimizing primer reuse. We call it the Markov Chain Monte Carlo Optimized Degenerate Primer Reuse (MCMC-ODPR) algorithm. Results After repeating the program 1020 times to assess the variance, an average of 17.14% fewer primers were found to be necessary using MCMC-ODPR for an equivalent coverage without implementing primer reuse. The algorithm was able to reuse primers up to five times. We compared MCMC-ODPR with single sequence primer design programs Primer3 and Primer-BLAST and achieved a lower primer cost per amplicon base covered of 0.21 and 0.19 and 0.18 primer nucleotides on three separate gene sequences, respectively. With multiple sequences, MCMC-ODPR achieved a lower cost per base covered of 0.19 than programs BatchPrimer3 and PAMPS, which achieved 0.25 and 0.64 primer nucleotides, respectively. Conclusions MCMC-ODPR is a useful tool for designing primers at various melting temperatures at good target coverage. By combining degeneracy with optimal primer reuse the user may increase coverage of sequences amplified by the designed primers at significantly lower costs. Our analyses showed that overall MCMC-ODPR outperformed the other primer-design programs in our study in terms of cost per covered base. PMID:23126469
Ashbaugh, Hayley R; Hoff, Nicole A; Doshi, Reena H; Alfonso, Vivian H; Gadoth, Adva; Mukadi, Patrick; Okitolonda-Wemakoy, Emile; Muyembe-Tamfum, Jean Jacques; Gerber, Sue K; Cherry, James D; Rimoin, Anne W
2018-01-25
Measles is a significant contributor to child mortality in the Democratic Republic of the Congo (DRC), despite routine immunization programs and supplementary immunization activities (SIA). Further, national immunization coverage levels may hide disparities among certain groups of children, making effective measles control even more challenging. This study describes measles vaccination coverage and reporting methods and identifies predictors of vaccination among children participating in the 2013-2014 DRC Demographic and Health Survey (DHS). We examined vaccination coverage of 6947 children aged 6-59 months. A multivariate logistic regression model was used to identify predictors of vaccination among children reporting vaccination via dated card in order to identify least reached children. We also assessed spatial distribution of vaccination report type by rural versus urban residence. Urban children with educated mothers were more likely to be vaccinated (OR = 4.1, 95% CI: 1.6, 10.7) versus children of mothers with no education, as were children in wealthier rural families (OR = 2.9, 95% CI: 1.9, 4.4). At the provincial level, urban areas more frequently reported vaccination via dated card than rural areas. Results indicate that, while the overall coverage level of 70% is too low, socioeconomic and geographic disparities also exist which could make some children even less likely to be vaccinated. Dated records of measles vaccination must be increased, and groups of children with the greatest need should be targeted. As access to routine vaccination services is limited in DRC, identifying and targeting under-reached children should be a strategic means of increasing country-wide effective measles control. Published by Elsevier Ltd.
Biotin-tagged platinum(iv) complexes as targeted cytostatic agents against breast cancer cells.
Muhammad, Nafees; Sadia, Nasreen; Zhu, Chengcheng; Luo, Cheng; Guo, Zijian; Wang, Xiaoyong
2017-09-05
A biotin-guided platinum IV complex is highly cytotoxic against breast cancer cells but hypotoxic against mammary epithelial cells. The mono-biotinylated Pt IV complex is superior to the di-biotinylated one and hence a promising drug candidate for the targeted therapy of breast cancer.
Shi, Chengyu; Guo, Bingqi; Cheng, Chih-Yao; Eng, Tony; Papanikolaou, Nikos
2010-09-21
A low-energy electronic brachytherapy source (EBS), the model S700 Axxent x-ray device developed by Xoft Inc., has been used in high dose rate (HDR) intracavitary accelerated partial breast irradiation (APBI) as an alternative to an Ir-192 source. The prescription dose and delivery schema of the electronic brachytherapy APBI plan are the same as the Ir-192 plan. However, due to its lower mean energy than the Ir-192 source, an EBS plan has dosimetric and biological features different from an Ir-192 source plan. Current brachytherapy treatment planning methods may have large errors in treatment outcome prediction for an EBS plan. Two main factors contribute to the errors: the dosimetric influence of tissue heterogeneities and the enhancement of relative biological effectiveness (RBE) of electronic brachytherapy. This study quantified the effects of these two factors and revisited the plan quality of electronic brachytherapy APBI. The influence of tissue heterogeneities is studied by a Monte Carlo method and heterogeneous 'virtual patient' phantoms created from CT images and structure contours; the effect of RBE enhancement in the treatment outcome was estimated by biologically effective dose (BED) distribution. Ten electronic brachytherapy APBI cases were studied. The results showed that, for electronic brachytherapy cases, tissue heterogeneities and patient boundary effect decreased dose to the target and skin but increased dose to the bones. On average, the target dose coverage PTV V(100) reduced from 95.0% in water phantoms (planned) to only 66.7% in virtual patient phantoms (actual). The actual maximum dose to the ribs is 3.3 times higher than the planned dose; the actual mean dose to the ipsilateral breast and maximum dose to the skin were reduced by 22% and 17%, respectively. Combining the effect of tissue heterogeneities and RBE enhancement, BED coverage of the target was 89.9% in virtual patient phantoms with RBE enhancement (actual BED) as compared to 95.2% in water phantoms without RBE enhancement (planned BED). About 10% increase in the source output is required to raise BED PTV V(100) to 95%. As a conclusion, the composite effect of dose reduction in the target due to heterogeneities and RBE enhancement results in a net effect of 5.3% target BED coverage loss for electronic brachytherapy. Therefore, it is suggested that about 10% increase in the source output may be necessary to achieve sufficient target coverage higher than 95%.
NASA Astrophysics Data System (ADS)
Shi, Chengyu; Guo, Bingqi; Cheng, Chih-Yao; Eng, Tony; Papanikolaou, Nikos
2010-09-01
A low-energy electronic brachytherapy source (EBS), the model S700 Axxent™ x-ray device developed by Xoft Inc., has been used in high dose rate (HDR) intracavitary accelerated partial breast irradiation (APBI) as an alternative to an Ir-192 source. The prescription dose and delivery schema of the electronic brachytherapy APBI plan are the same as the Ir-192 plan. However, due to its lower mean energy than the Ir-192 source, an EBS plan has dosimetric and biological features different from an Ir-192 source plan. Current brachytherapy treatment planning methods may have large errors in treatment outcome prediction for an EBS plan. Two main factors contribute to the errors: the dosimetric influence of tissue heterogeneities and the enhancement of relative biological effectiveness (RBE) of electronic brachytherapy. This study quantified the effects of these two factors and revisited the plan quality of electronic brachytherapy APBI. The influence of tissue heterogeneities is studied by a Monte Carlo method and heterogeneous 'virtual patient' phantoms created from CT images and structure contours; the effect of RBE enhancement in the treatment outcome was estimated by biologically effective dose (BED) distribution. Ten electronic brachytherapy APBI cases were studied. The results showed that, for electronic brachytherapy cases, tissue heterogeneities and patient boundary effect decreased dose to the target and skin but increased dose to the bones. On average, the target dose coverage PTV V100 reduced from 95.0% in water phantoms (planned) to only 66.7% in virtual patient phantoms (actual). The actual maximum dose to the ribs is 3.3 times higher than the planned dose; the actual mean dose to the ipsilateral breast and maximum dose to the skin were reduced by 22% and 17%, respectively. Combining the effect of tissue heterogeneities and RBE enhancement, BED coverage of the target was 89.9% in virtual patient phantoms with RBE enhancement (actual BED) as compared to 95.2% in water phantoms without RBE enhancement (planned BED). About 10% increase in the source output is required to raise BED PTV V100 to 95%. As a conclusion, the composite effect of dose reduction in the target due to heterogeneities and RBE enhancement results in a net effect of 5.3% target BED coverage loss for electronic brachytherapy. Therefore, it is suggested that about 10% increase in the source output may be necessary to achieve sufficient target coverage higher than 95%.
Adeyinka, Daniel A; Evans, Meirion R; Ozigbu, Chamberline E; van Woerden, Hugo; Adeyinka, Esther F; Oladimeji, Olanrewaju; Aimakhu, Chris; Odoh, Deborah; Chamla, Dick
2017-03-01
Many sub-Saharan African countries have massively scaled-up their antiretroviral treatment (ART) programmes, but many national programmes still show large gaps in paediatric ART coverage making it challenging to reduce AIDS-related deaths among HIV-infected children. We sought to identify enablers of paediatric ART coverage in Africa by examining the relationship between paediatric ART coverage and socioeconomic parameters measured at the population level so as to accelerate reaching the 90-90-90 targets. Ecological analyses of paediatric ART coverage and socioeconomic indicators were performed. The data were obtained from the United Nations agencies and Forum for a new World Governance reports for the 21 Global Plan priority countries in Africa with highest burden of mother-to-child HIV transmission. Spearman's correlation and median regression were utilized to explore possible enablers of paediatric ART coverage. Factors associated with paediatric ART coverage included adult literacy (r=0.6, p=0.004), effective governance (r=0.6, p=0.003), virology testing by 2 months of age (r=0.9, p=0.001), density of healthcare workers per 10,000 population (r=0.6, p=0.007), and government expenditure on health (r=0.5, p=0.046). The paediatric ART coverage had a significant inverse relationship with the national mother-to-child transmission (MTCT) rate (r=-0.9, p<0.001) and gender inequality index (r=-0.6, p=0.006). Paediatric ART coverage had no relationship with poverty and HIV stigma indices. Low paediatric ART coverage continues to hamper progress towards eliminating AIDS-related deaths in HIV-infected children. Achieving this requires full commitment to a broad range of socioeconomic development goals. Copyright© by the National Institute of Public Health, Prague 2017
Decision making with regard to antiviral intervention during an influenza pandemic.
Shim, Eunha; Chapman, Gretchen B; Galvani, Alison P
2010-01-01
Antiviral coverage is defined by the proportion of the population that takes antiviral prophylaxis or treatment. High coverage of an antiviral drug has epidemiological and evolutionary repercussions. Antivirals select for drug resistance within the population, and individuals may experience adverse effects. To determine optimal antiviral coverage in the context of an influenza outbreak, we compared 2 perspectives: 1) the individual level (the Nash perspective), and 2) the population level (utilitarian perspective). We developed an epidemiological game-theoretic model of an influenza pandemic. The data sources were published literature and a national survey. The target population was the US population. The time horizon was 6 months. The perspective was individuals and the population overall. The interventions were antiviral prophylaxis and treatment. The outcome measures were the optimal coverage of antivirals in an influenza pandemic. At current antiviral pricing, the optimal Nash strategy is 0% coverage for prophylaxis and 30% coverage for treatment, whereas the optimal utilitarian strategy is 19% coverage for prophylaxis and 100% coverage for treatment. Subsidizing prophylaxis by $440 and treatment by $85 would bring the Nash and utilitarian strategies into alignment. For both prophylaxis and treatment, the optimal antiviral coverage decreases as pricing of antivirals increases. Our study does not incorporate the possibility of an effective vaccine and lacks probabilistic sensitivity analysis. Our survey also does not completely represent the US population. Because our model assumes a homogeneous population and homogeneous antiviral pricing, it does not incorporate heterogeneity of preference. The optimal antiviral coverage from the population perspective and individual perspectives differs widely for both prophylaxis and treatment strategies. Optimal population and individual strategies for prophylaxis and treatment might be aligned through subsidization.
Hosseinpoor, Ahmad Reza; Victora, Cesar G; Bergen, Nicole; Barros, Aluisio J D; Boerma, Ties
2011-12-01
To measure within-country wealth-related inequality in the health service coverage gap of maternal and child health indicators in sub-Saharan Africa and quantify its contribution to the national health service coverage gap. Coverage data for child and maternal health services in 28 sub-Saharan African countries were obtained from the 2000-2008 Demographic Health Survey. For each country, the national coverage gap was determined for an overall health service coverage index and select individual health service indicators. The data were then additively broken down into the coverage gap in the wealthiest quintile (i.e. the proportion of the quintile lacking a required health service) and the population attributable risk (an absolute measure of within-country wealth-related inequality). In 26 countries, within-country wealth-related inequality accounted for more than one quarter of the national overall coverage gap. Reducing such inequality could lower this gap by 16% to 56%, depending on the country. Regarding select individual health service indicators, wealth-related inequality was more common in services such as skilled birth attendance and antenatal care, and less so in family planning, measles immunization, receipt of a third dose of vaccine against diphtheria, pertussis and tetanus and treatment of acute respiratory infections in children under 5 years of age. The contribution of wealth-related inequality to the child and maternal health service coverage gap differs by country and type of health service, warranting case-specific interventions. Targeted policies are most appropriate where high within-country wealth-related inequality exists, and whole-population approaches, where the health-service coverage gap is high in all quintiles.
Sensor-driven area coverage for an autonomous fixed-wing unmanned aerial vehicle.
Paull, Liam; Thibault, Carl; Nagaty, Amr; Seto, Mae; Li, Howard
2014-09-01
Area coverage with an onboard sensor is an important task for an unmanned aerial vehicle (UAV) with many applications. Autonomous fixed-wing UAVs are more appropriate for larger scale area surveying since they can cover ground more quickly. However, their non-holonomic dynamics and susceptibility to disturbances make sensor coverage a challenging task. Most previous approaches to area coverage planning are offline and assume that the UAV can follow the planned trajectory exactly. In this paper, this restriction is removed as the aircraft maintains a coverage map based on its actual pose trajectory and makes control decisions based on that map. The aircraft is able to plan paths in situ based on sensor data and an accurate model of the on-board camera used for coverage. An information theoretic approach is used that selects desired headings that maximize the expected information gain over the coverage map. In addition, the branch entropy concept previously developed for autonomous underwater vehicles is extended to UAVs and ensures that the vehicle is able to achieve its global coverage mission. The coverage map over the workspace uses the projective camera model and compares the expected area of the target on the ground and the actual area covered on the ground by each pixel in the image. The camera is mounted on a two-axis gimbal and can either be stabilized or optimized for maximal coverage. Hardware-in-the-loop simulation results and real hardware implementation on a fixed-wing UAV show the effectiveness of the approach. By including the already developed automatic takeoff and landing capabilities, we now have a fully automated and robust platform for performing aerial imagery surveys.
O'Keefe, Daniel; Scott, Nick; Aitken, Campbell; Dietze, Paul
2017-07-01
Needle and syringe program (NSP) coverage is often calculated at the individual level. This method relates sterile needle and syringe acquisition to injecting frequency, resulting in a percentage of injecting episodes that utilise a sterile syringe. Most previous research using this method was restricted by their cross-sectional design, calling for longitudinal exploration of coverage. We used the data of 518 participants from an ongoing cohort of people who inject drugs in Melbourne, Australia. We calculated individual-level syringe coverage for the two weeks prior to each interview, then dichotomised the outcome as either "sufficient" (≥100% of injecting episodes covered by at least one reported sterile syringe) or "insufficient" (<100%). Time-variant predictors of change in recent coverage (from sufficient to insufficient coverage) were estimated longitudinally using logistic regression with fixed effects for each participant. Transitioning to methamphetamine injection (AOR:2.16, p=0.004) and a newly positive HCV RNA test result (AOR:4.93, p=0.001) were both associated with increased odds of change to insufficient coverage, whilst change to utilising NSPs as the primary source of syringe acquisition (AOR: 0.41, p=0.003) and opioid substitution therapy (OST) enrolment (AOR:0.51, p=0.013) were protective against a change to insufficient coverage. We statistically tested the transitions between time-variant exposure sub-groups and transitions in individual-level syringe coverage. Our results give important insights into means of improving coverage at the individual level, suggesting that methamphetamine injectors should be targeted, whilst both OST prescription and NSP should be expanded. Copyright © 2017 Elsevier B.V. All rights reserved.
Decision Making with Regard to Antiviral Intervention during an Influenza Pandemic
Shim, Eunha; Chapman, Gretchen B.; Galvani, Alison P.
2012-01-01
Background Antiviral coverage is defined by the proportion of the population that takes antiviral prophylaxis or treatment. High coverage of an antiviral drug has epidemiological and evolutionary repercussions. Antivirals select for drug resistance within the population, and individuals may experience adverse effects. To determine optimal antiviral coverage in the context of an influenza outbreak, we compared 2 perspectives: 1) the individual level (the Nash perspective), and 2) the population level (utilitarian perspective). Methods We developed an epidemiological game-theoretic model of an influenza pandemic. The data sources were published literature and a national survey. The target population was the US population. The time horizon was 6 months. The perspective was individuals and the population overall. The interventions were antiviral prophylaxis and treatment. The outcome measures were the optimal coverage of antivirals in an influenza pandemic. Results At current antiviral pricing, the optimal Nash strategy is 0% coverage for prophylaxis and 30% coverage for treatment, whereas the optimal utilitarian strategy is 19% coverage for prophylaxis and 100% coverage for treatment. Subsidizing prophylaxis by $440 and treatment by $85 would bring the Nash and utilitarian strategies into alignment. For both prophylaxis and treatment, the optimal antiviral coverage decreases as pricing of antivirals increases. Our study does not incorporate the possibility of an effective vaccine and lacks probabilistic sensitivity analysis. Our survey also does not completely represent the US population. Because our model assumes a homogeneous population and homogeneous antiviral pricing, it does not incorporate heterogeneity of preference. Conclusions The optimal antiviral coverage from the population perspective and individual perspectives differs widely for both prophylaxis and treatment strategies. Optimal population and individual strategies for prophylaxis and treatment might be aligned through subsidization. PMID:20634545
DOE Office of Scientific and Technical Information (OSTI.GOV)
Masi, K; Ditman, M; Marsh, R
Purpose: There is potentially a wide variation in plan quality for a certain disease site, even for clinics located in the same system of hospitals. We have used a prostate-specific knowledge-based planning (KBP) model as a quality control tool to investigate the variation in prostate treatment planning across a network of affiliated radiation oncology departments. Methods: A previously created KBP model was applied to 10 patients each from 4 community-based clinics (Clinics A, B, C, and D). The KBP model was developed using RapidPlan (Eclipse v13.5, Varian Medical Systems) from 60 prostate/prostate bed IMRT plans that were originally planned usingmore » an in-house treatment planning system at the central institution of the community-based clinics. The dosimetric plan quality (target coverage and normal-tissue sparing) of each model-generated plan was compared to the respective clinically-used plan. Each community-based clinic utilized the same planning goals to develop the clinically-used plans that were used at the main institution. Results: Across all 4 clinics, the model-generated plans decreased the mean dose to the rectum by varying amounts (on average, 12.5, 2.6, 4.5, and 2.7 Gy for Clinics A, B, C, and D, respectively). The mean dose to the bladder also decreased with the model-generated plans (5.4, 2.3, 3.0, and 4.1 Gy, respectively). The KBP model also identified that target coverage (D95%) improvements were possible for for Clinics A, B, and D (0.12, 1.65, and 2.75%) while target coverage decreased by 0.72% for Clinic C, demonstrating potentially different trade-offs made in clinical plans at different institutions. Conclusion: Quality control of dosimetric plan quality across a system of radiation oncology practices is possible with knowledge-based planning. By using a quality KBP model, smaller community-based clinics can potentially identify the areas of their treatment plans that may be improved, whether it be in normal-tissue sparing or improved target coverage. M. Matuszak has research funding for KBP from Varian Medical Systems.« less
Chi, F; Wu, S; Zhou, J; Li, F; Sun, J; Lin, Q; Lin, H; Guan, X; He, Z
2015-05-01
This study determined the dosimetric comparison of moderate deep inspiration breath-hold using active breathing control and free-breathing intensity-modulated radiotherapy (IMRT) after breast-conserving surgery for left-sided breast cancer. Thirty-one patients were enrolled. One free breathe and two moderate deep inspiration breath-hold images were obtained. A field-in-field-IMRT free-breathing plan and two field-in-field-IMRT moderate deep inspiration breath-holding plans were compared in the dosimetry to target volume coverage of the glandular breast tissue and organs at risks for each patient. The breath-holding time under moderate deep inspiration extended significantly after breathing training (P<0.05). There was no significant difference between the free-breathing and moderate deep inspiration breath-holding in the target volume coverage. The volume of the ipsilateral lung in the free-breathing technique were significantly smaller than the moderate deep inspiration breath-holding techniques (P<0.05); however, there was no significant difference between the two moderate deep inspiration breath-holding plans. There were no significant differences in target volume coverage between the three plans for the field-in-field-IMRT (all P>0.05). The dose to ipsilateral lung, coronary artery and heart in the field-in-field-IMRT were significantly lower for the free-breathing plan than for the two moderate deep inspiration breath-holding plans (all P<0.05); however, there was no significant difference between the two moderate deep inspiration breath-holding plans. The whole-breast field-in-field-IMRT under moderate deep inspiration breath-hold with active breathing control after breast-conserving surgery in left-sided breast cancer can reduce the irradiation volume and dose to organs at risks. There are no significant differences between various moderate deep inspiration breath-holding states in the dosimetry of irradiation to the field-in-field-IMRT target volume coverage and organs at risks. Copyright © 2015 Société française de radiothérapie oncologique (SFRO). Published by Elsevier SAS. All rights reserved.
Encaoua, J; Abgral, R; Leleu, C; El Kabbaj, O; Caradec, P; Bourhis, D; Pradier, O; Schick, U
2017-06-01
To study the impact on radiotherapy planning of an automatically segmented target volume delineation based on ( 18 F)-fluorodeoxy-D-glucose (FDG)-hybrid positron emission tomography-computed tomography (PET-CT) compared to a manually delineation based on computed tomography (CT) in oesophageal carcinoma patients. Fifty-eight patients diagnosed with oesophageal cancer between September 2009 and November 2014 were included. The majority had squamous cell carcinoma (84.5 %), and advanced stage (37.9 % were stade IIIA) and 44.8 % had middle oesophageal lesion. Gross tumour volumes were retrospectively defined based either manually on CT or automatically on coregistered PET/CT images using three different threshold methods: standard-uptake value (SUV) of 2.5, 40 % of maximum intensity and signal-to-background ratio. Target volumes were compared in length, volume and using the index of conformality. Radiotherapy plans to the dose of 50Gy and 66Gy using intensity-modulated radiotherapy were generated and compared for both data sets. Planification target volume coverage and doses delivered to organs at risk (heart, lung and spinal cord) were compared. The gross tumour volume based manually on CT was significantly longer than that automatically based on signal-to-background ratio (6.4cm versus 5.3cm; P<0.008). Doses to the lungs (V20, D mean ), heart (V40), and spinal cord (D max ) were significantly lower on plans using the PTV SBR . The PTV SBR coverage was statistically better than the PTV CT coverage on both plans. (50Gy: P<0.0004 and 66Gy: P<0.0006). The automatic PET segmentation algorithm based on the signal-to-background ratio method for the delineation of oesophageal tumours is interesting, and results in better target volume coverage and decreased dose to organs at risk. This may allow dose escalation up to 66Gy to the gross tumour volume. Copyright © 2017 Société française de radiothérapie oncologique (SFRO). Published by Elsevier SAS. All rights reserved.
Hybrid adaptive radiotherapy with on-line MRI in cervix cancer IMRT.
Oh, Seungjong; Stewart, James; Moseley, Joanne; Kelly, Valerie; Lim, Karen; Xie, Jason; Fyles, Anthony; Brock, Kristy K; Lundin, Anna; Rehbinder, Henrik; Milosevic, Michael; Jaffray, David; Cho, Young-Bin
2014-02-01
Substantial organ motion and tumor shrinkage occur during radiotherapy for cervix cancer. IMRT planning studies have shown that the quality of radiation delivery is influenced by these anatomical changes, therefore the adaptation of treatment plans may be warranted. Image guidance with off-line replanning, i.e. hybrid-adaptation, is recognized as one of the most practical adaptation strategies. In this study, we investigated the effects of soft tissue image guidance using on-line MR while varying the frequency of off-line replanning on the adaptation of cervix IMRT. 33 cervical cancer patients underwent planning and weekly pelvic MRI scans during radiotherapy. 5 patients of 33 were identified in a previous retrospective adaptive planning study, in which the coverage of gross tumor volume/clinical target volume (GTV/CTV) was not acceptable given single off-line IMRT replan using a 3mm PTV margin with bone matching. These 5 patients and a randomly selected 10 patients from the remaining 28 patients, a total of 15 patients of 33, were considered in this study. Two matching methods for image guidance (bone to bone and soft tissue to dose matrix) and three frequencies of off-line replanning (none, single, and weekly) were simulated and compared with respect to target coverage (cervix, GTV, lower uterus, parametrium, upper vagina, tumor related CTV and elective lymph node CTV) and OAR sparing (bladder, bowel, rectum, and sigmoid). Cost (total process time) and benefit (target coverage) were analyzed for comparison. Hybrid adaptation (image guidance with off-line replanning) significantly enhanced target coverage for both 5 difficult and 10 standard cases. Concerning image guidance, bone matching was short of delivering enough doses for 5 difficult cases even with a weekly off-line replan. Soft tissue image guidance proved successful for all cases except one when single or more frequent replans were utilized in the difficult cases. Cost and benefit analysis preferred (soft tissue) image guidance over (frequent) off-line replanning. On-line MRI based image guidance (with combination of dose distribution) is a crucial element for a successful hybrid adaptive radiotherapy. Frequent off-line replanning adjuvantly enhances adaptation quality. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
Fenimore, Paul W.; Foley, Brian T.; Bakken, Russell R.; Thurmond, James R.; Yusim, Karina; Yoon, Hyejin; Parker, Michael; Hart, Mary Kate; Dye, John M.; Korber, Bette; Kuiken, Carla
2012-01-01
We report the rational design and in vivo testing of mosaic proteins for a polyvalent pan-filoviral vaccine using a computational strategy designed for the Human Immunodeficiency Virus type 1 (HIV-1) but also appropriate for Hepatitis C virus (HCV) and potentially other diverse viruses. Mosaics are sets of artificial recombinant proteins that are based on natural proteins. The recombinants are computationally selected using a genetic algorithm to optimize the coverage of potential cytotoxic T lymphocyte (CTL) epitopes. Because evolutionary history differs markedly between HIV-1 and filoviruses, we devised an adapted computational technique that is effective for sparsely sampled taxa; our first significant result is that the mosaic technique is effective in creating high-quality mosaic filovirus proteins. The resulting coverage of potential epitopes across filovirus species is superior to coverage by any natural variants, including current vaccine strains with demonstrated cross-reactivity. The mosaic cocktails are also robust: mosaics substantially outperformed natural strains when computationally tested against poorly sampled species and more variable genes. Furthermore, in a computational comparison of cross-reactive potential a design constructed prior to the Bundibugyo outbreak performed nearly as well against all species as an updated design that included Bundibugyo. These points suggest that the mosaic designs would be more resilient than natural-variant vaccines against future Ebola outbreaks dominated by novel viral variants. We demonstrate in vivo immunogenicity and protection against a heterologous challenge in a mouse model. This design work delineates the likely requirements and limitations on broadly-protective filoviral CTL vaccines. PMID:23056184
In vitro evaluation of tigemonam, a novel oral monobactam.
Tanaka, S K; Summerill, R A; Minassian, B F; Bush, K; Visnic, D A; Bonner, D P; Sykes, R B
1987-01-01
Tigemonam, a novel, orally administered monobactam, exhibited potent and specific activity in vitro against members of the family Enterobacteriaceae, Haemophilus influenzae, and Neisseria gonorrhoeae. Its activity was variable to poor against gram-positive bacteria, Acinetobacter spp., Pseudomonas aeruginosa, and anaerobes. Within its spectrum of activity, tigemonam was far superior to oral antibiotics currently available, including amoxicillin-clavulanic acid, cefaclor, and trimethoprim-sulfamethoxazole. In addition, tigemonam was superior to cefuroxime, which is under development as an oral pro-drug, and more active than cefixime against several genera of the Enterobacteriaceae. The activity of tigemonam against the enteric bacteria, Haemophilus species, and Neisseria species was, in general, comparable to that of the quinolone norfloxacin. The excellent activity of tigemonam against beta-lactamase-producing bacteria reflected its marked stability to hydrolysis by isolated enzymes. The expanded spectrum of activity against gram-negative bacteria observed with tigemonam thus extends oral beta-lactam coverage to include members of the Enterobacteriaceae that are intrinsically or enzymatically resistant to broad-spectrum penicillins and cephalosporins. PMID:3105448
Synthetic aperture radar operator tactical target acquisition research
NASA Technical Reports Server (NTRS)
Hershberger, M. L.; Craig, D. W.
1978-01-01
A radar target acquisition research study was conducted to access the effects of two levels of 13 radar sensor, display, and mission parameters on operator tactical target acquisition. A saturated fractional-factorial screening design was employed to examine these parameters. Data analysis computed ETA squared values for main and second-order effects for the variables tested. Ranking of the research parameters in terms of importance to system design revealed four variables (radar coverage, radar resolution/multiple looks, display resolution, and display size) accounted for 50 percent of the target acquisition probability variance.
Ruschin, Mark; Nordström, Håkan; Kjäll, Per; Cho, Young-Bin; Jaffray, David
2009-06-01
This investigation involves quantifying the extent of intracranial peripheral dose arising from simulated targets situated in the skull-base or upper-spine region using the Leksell GammaKnife Perfexion treatment unit. For each of three spherical target volumes--denoted as Vs (4 cm3), VM (18 cm3), and VL (60 cm3)--three treatment plans were manually generated, one for each of the three collimator sizes--4, 8, and 16 mm. Each of the plans was delivered to a spherical dosimetry phantom with an insert containing EBT Gafchromic film. The total dose at 70 mm from the targets' edges, %D(70 mm), was measured as a function of elevation angle and expressed as a percentage of the prescription dose. The film insert was placed centered in the median sagittal plane (Leksell X = 100) and %D(70 mm) was measured for the angular range from 0 degree (superior/along Z axis) to 90 degrees (anterior/along Y axis). For a given collimator i, the irradiation time ti to treat a spherical target of volume V using the 50% isodose line was observed to follow a power-law relationship of the form ti = Ai(V/ Vi)n where Ai was the maximum dose divided by collimator dose rate and Vi was the volume encompassed by the 50% isodose line for a single shot. The mean value of n was 0.61 (range: 0.61-0.62). Along the superior (Z) direction (angle=0 degree) and up to angles of around 30 degrees, the %D(70 mm) was always highest for the 4 mm plans, followed by the 8 mm, followed by the 16 mm. In this angular range, the maximum measured %D(70 mm) was 1.7% of the prescription dose. The intracranial peripheral dose along the superior direction (combined scatter and leakage dose) resulting from irradiation of upper-spine or base-of-skull lesions is measured to be less than 2% of the prescription dose, even for very large (60 cm3) targets. The results of this study indicate that, for a given target volume, treatment plans consisting of only 4 mm shots yield larger peripheral dose in the superior direction than 8 mm shot only plans, which in turn yield larger peripheral dose than 16 mm shot only plans.
Exploring the relationship between population density and maternal health coverage.
Hanlon, Michael; Burstein, Roy; Masters, Samuel H; Zhang, Raymond
2012-11-21
Delivering health services to dense populations is more practical than to dispersed populations, other factors constant. This engenders the hypothesis that population density positively affects coverage rates of health services. This hypothesis has been tested indirectly for some services at a local level, but not at a national level. We use cross-sectional data to conduct cross-country, OLS regressions at the national level to estimate the relationship between population density and maternal health coverage. We separately estimate the effect of two measures of density on three population-level coverage rates (6 tests in total). Our coverage indicators are the fraction of the maternal population completing four antenatal care visits and the utilization rates of both skilled birth attendants and in-facility delivery. The first density metric we use is the percentage of a population living in an urban area. The second metric, which we denote as a density score, is a relative ranking of countries by population density. The score's calculation discounts a nation's uninhabited territory under the assumption those areas are irrelevant to service delivery. We find significantly positive relationships between our maternal health indicators and density measures. On average, a one-unit increase in our density score is equivalent to a 0.2% increase in coverage rates. Countries with dispersed populations face higher burdens to achieve multinational coverage targets such as the United Nations' Millennial Development Goals.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Small, Katherine; Kelly, Chris; Beldham-Collins, Rachael
A comparative study was conducted comparing the difference between (1) conformal radiotherapy (CRT) to the whole breast with sequential boost excision cavity plans and (2) intensity-modulated radiation therapy (IMRT) to the whole breast with simultaneously integrated boost to the excision cavity. The computed tomography (CT) data sets of 25 breast cancer patients were used and the results analysed to determine if either planning method produced superior plans. CT data sets from 25 past breast cancer patients were planned using (1) CRT prescribed to 50 Gy in 25 fractions (Fx) to the whole-breast planning target volume (PTV) and 10 Gy inmore » 5Fx to the excision cavity and (2) IMRT prescribed to 60 Gy in 25Fx, with 60 Gy delivered to the excision cavity PTV and 50 Gy delivered to the whole-breast PTV, treated simultaneously. In total, 50 plans were created, with each plan evaluated by PTV coverage using conformity indices, plan maximum dose, lung dose, and heart maximum dose for patients with left-side lesions. CRT plans delivered the lowest plan maximum doses in 56% of cases (average CRT = 6314.34 cGy, IMRT = 6371.52 cGy). They also delivered the lowest mean lung dose in 68% of cases (average CRT = 1206.64 cGy, IMRT = 1288.37 cGy) and V20 in 88% of cases (average CRT = 20.03%, IMRT = 21.73%) and V30 doses in 92% of cases (average CRT = 16.82%, IMRT = 17.97%). IMRT created more conformal plans, using both conformity index and conformation number, in every instance, and lower heart maximum doses in 78.6% of cases (average CRT = 5295.26 cGy, IMRT = 5209.87 cGy). IMRT plans produced superior dose conformity and shorter treatment duration, but a slightly higher planning maximum and increased lung doses. IMRT plans are also faster to treat on a daily basis, with shorter fractionation.« less
Circular revisit orbits design for responsive mission over a single target
NASA Astrophysics Data System (ADS)
Li, Taibo; Xiang, Junhua; Wang, Zhaokui; Zhang, Yulin
2016-10-01
The responsive orbits play a key role in addressing the mission of Operationally Responsive Space (ORS) because of their capabilities. These capabilities are usually focused on supporting specific targets as opposed to providing global coverage. One subtype of responsive orbits is repeat coverage orbit which is nearly circular in most remote sensing applications. This paper deals with a special kind of repeating ground track orbit, referred to as circular revisit orbit. Different from traditional repeat coverage orbits, a satellite on circular revisit orbit can visit a target site at both the ascending and descending stages in one revisit cycle. This typology of trajectory allows a halving of the traditional revisit time and does a favor to get useful information for responsive applications. However the previous reported numerical methods in some references often cost lots of computation or fail to obtain such orbits. To overcome this difficulty, an analytical method to determine the existence conditions of the solutions to revisit orbits is presented in this paper. To this end, the mathematical model of circular revisit orbit is established under the central gravity model and the J2 perturbation. A constraint function of the circular revisit orbit is introduced, and the monotonicity of that function has been studied. The existent conditions and the number of such orbits are naturally worked out. Taking the launch cost into consideration, optimal design model of circular revisit orbit is established to achieve a best orbit which visits a target twice a day in the morning and in the afternoon respectively for several days. The result shows that it is effective to apply circular revisit orbits in responsive application such as reconnoiter of natural disaster.
3D model generation using an airborne swarm
DOE Office of Scientific and Technical Information (OSTI.GOV)
Clark, R. A.; Punzo, G.; Macdonald, M.
2015-03-31
Using an artificial kinematic field to provide co-ordination between multiple inspection UAVs, the authors herein demonstrate full 3D modelling capability based on a photogrammetric system. The operation of the system is demonstrated by generating a full 3D surface model of an intermediate level nuclear waste storage drum. Such drums require periodic inspection to ensure that drum distortion or corrosion is carefully monitored. Performing this inspection with multiple airborne platforms enables rapid inspection of structures that are inaccessible to on-surface remote vehicles and are in human-hazardous environments. A three-dimensional surface-meshed model of the target can then be constructed in post-processing throughmore » photogrammetry analysis of the visual inspection data. The inspection environment uses a tracking system to precisely monitor the position of each aerial vehicle within the enclosure. The vehicles used are commercially available Parrot AR. Drone quadcopters, controlled through a computer interface connected over an IEEE 802.11n (WiFi) network, implementing a distributed controller for each vehicle. This enables the autonomous and distributed elements of the control scheme to be retained, while alleviating the vehicles of the control algorithm’s computational load. The control scheme relies on a kinematic field defined with the target at its centre. This field defines the trajectory for all the drones in the volume relative to the central target, enabling the drones to circle the target at a set radius while avoiding drone collisions. This function enables complete coverage along the height of the object, which is assured by transitioning to another inspection band only after completing circumferential coverage. Using a swarm of vehicles, the time until complete coverage can be significantly reduced.« less
3D model generation using an airborne swarm
NASA Astrophysics Data System (ADS)
Clark, R. A.; Punzo, G.; Dobie, G.; MacLeod, C. N.; Summan, R.; Pierce, G.; Macdonald, M.; Bolton, G.
2015-03-01
Using an artificial kinematic field to provide co-ordination between multiple inspection UAVs, the authors herein demonstrate full 3D modelling capability based on a photogrammetric system. The operation of the system is demonstrated by generating a full 3D surface model of an intermediate level nuclear waste storage drum. Such drums require periodic inspection to ensure that drum distortion or corrosion is carefully monitored. Performing this inspection with multiple airborne platforms enables rapid inspection of structures that are inaccessible to on-surface remote vehicles and are in human-hazardous environments. A three-dimensional surface-meshed model of the target can then be constructed in post-processing through photogrammetry analysis of the visual inspection data. The inspection environment uses a tracking system to precisely monitor the position of each aerial vehicle within the enclosure. The vehicles used are commercially available Parrot AR. Drone quadcopters, controlled through a computer interface connected over an IEEE 802.11n (WiFi) network, implementing a distributed controller for each vehicle. This enables the autonomous and distributed elements of the control scheme to be retained, while alleviating the vehicles of the control algorithm's computational load. The control scheme relies on a kinematic field defined with the target at its centre. This field defines the trajectory for all the drones in the volume relative to the central target, enabling the drones to circle the target at a set radius while avoiding drone collisions. This function enables complete coverage along the height of the object, which is assured by transitioning to another inspection band only after completing circumferential coverage. Using a swarm of vehicles, the time until complete coverage can be significantly reduced.
Global investment targets for malaria control and elimination between 2016 and 2030
Patouillard, Edith; Griffin, Jamie; Bhatt, Samir; Ghani, Azra; Cibulskis, Richard
2017-01-01
Background Access to malaria control interventions falls short of universal health coverage. The Global Technical Strategy for malaria targets at least 90% reduction in case incidence and mortality rates, and elimination in 35 countries by 2030. The potential to reach these targets will be determined in part by investments in malaria. This study estimates the financing required for malaria control and elimination over the 2016–2030 period. Methods A mathematical transmission model was used to explore the impact of increasing intervention coverage on burden and costs. The cost analysis took a public provider perspective covering all 97 malaria endemic countries and territories in 2015. All control interventions currently recommended by the WHO were considered. Cost data were sourced from procurement databases, the peer-reviewed literature, national malaria strategic plans, the WHO-CHOICE project and key informant interviews. Results Annual investments of $6.4 billion (95% uncertainty interval (UI $4.5–$9.0 billion)) by 2020, $7.7 billion (95% UI $5.4–$10.9 billion) by 2025 and $8.7 billion (95% UI $6.0–$12.3 billion) by 2030 will be required to reach the targets set in the Global Technical Strategy. These are equivalent to annual investment per person at risk of malaria of US$3.90 by 2020, US$4.30 by 2025 and US$4.40 by 2030, compared with US$2.30 if interventions were sustained at current coverage levels. The 20 countries with the highest burden in 2015 will require 88% of the total investment. Conclusions Given the challenges in increasing domestic and international funding, the efficient use of currently available resources should be a priority. PMID:29242750
Baumbach, Andreas; Lansky, Alexandra J; Onuma, Yoshi; Asano, Taku; Johnson, Thomas; Anderson, Richard; Kiemeneij, Ferdinand; Zheng, Ming; Van Royen, Niels; Slagboom, Ton; Vlachojannis, Georg; Xu, Bo; Serruys, Patrick; Wijns, William
2018-06-12
Durable polymer drug-eluting stents (DP DES) may contribute to persistent inflammation, delayed endothelial healing and subsequent late DES thrombosis. The aim of this Optical Coherence Tomography (OCT) sub-study was to compare healing and neointimal coverage of a novel bioabsorbable polymer sirolimus-eluting stent (FIREHAWK®) (BP DES) versus the DP DES (XIENCE) at 90 days in an all comers patient population. The TARGET All Comers study is a prospective multicenter randomised post-market trial of 1656 patients randomised 1:1 to FIREHAWK or XIENCE at 21 centers in 10 European countries. The TARGET OCT sub-study enrolled 36 consecutive patients with 52 lesions at 6 centers proficient in OCT. Follow-up OCT was performed at 3 months or prior to revascularisation when occurring before the 3-month window. The substudy was designed for non-inferiority of the primary endpoint of neointimal thickness. At follow-up, the mean neointimal thickness by OCT (52 lesions, Firehawk, n=24; Xience, n=28), was not significantly different between groups (Firehawk 75.5μm vs Xience V 82.3 μm) meeting the primary endpoint of non-inferiority (Pnoninferiority<0.001). The percentage of stent strut coverage was high in both groups (strut level: 99.9% ± 0.3 vs 100% ± 0.1, p=0.26), and the proportion of malapposed struts (1.0±1.6% vs. 1.2±2.0%, p=0.51) was low in both groups. Based on OCT, the FIREHAWK BP DES has a similar healing response 3 months after implantation compared to the DP DES, with near complete strut coverage, moderate neointima formation and minimal strut malapposition.
Global investment targets for malaria control and elimination between 2016 and 2030.
Patouillard, Edith; Griffin, Jamie; Bhatt, Samir; Ghani, Azra; Cibulskis, Richard
2017-01-01
Access to malaria control interventions falls short of universal health coverage. The Global Technical Strategy for malaria targets at least 90% reduction in case incidence and mortality rates, and elimination in 35 countries by 2030. The potential to reach these targets will be determined in part by investments in malaria. This study estimates the financing required for malaria control and elimination over the 2016-2030 period. A mathematical transmission model was used to explore the impact of increasing intervention coverage on burden and costs. The cost analysis took a public provider perspective covering all 97 malaria endemic countries and territories in 2015. All control interventions currently recommended by the WHO were considered. Cost data were sourced from procurement databases, the peer-reviewed literature, national malaria strategic plans, the WHO-CHOICE project and key informant interviews. Annual investments of $6.4 billion (95% uncertainty interval (UI $4.5-$9.0 billion)) by 2020, $7.7 billion (95% UI $5.4-$10.9 billion) by 2025 and $8.7 billion (95% UI $6.0-$12.3 billion) by 2030 will be required to reach the targets set in the Global Technical Strategy. These are equivalent to annual investment per person at risk of malaria of US$3.90 by 2020, US$4.30 by 2025 and US$4.40 by 2030, compared with US$2.30 if interventions were sustained at current coverage levels. The 20 countries with the highest burden in 2015 will require 88% of the total investment. Given the challenges in increasing domestic and international funding, the efficient use of currently available resources should be a priority.
Jiang, Yu; Simon, Steve; Mayo, Matthew S; Gajewski, Byron J
2015-02-20
Slow recruitment in clinical trials leads to increased costs and resource utilization, which includes both the clinic staff and patient volunteers. Careful planning and monitoring of the accrual process can prevent the unnecessary loss of these resources. We propose two hierarchical extensions to the existing Bayesian constant accrual model: the accelerated prior and the hedging prior. The new proposed priors are able to adaptively utilize the researcher's previous experience and current accrual data to produce the estimation of trial completion time. The performance of these models, including prediction precision, coverage probability, and correct decision-making ability, is evaluated using actual studies from our cancer center and simulation. The results showed that a constant accrual model with strongly informative priors is very accurate when accrual is on target or slightly off, producing smaller mean squared error, high percentage of coverage, and a high number of correct decisions as to whether or not continue the trial, but it is strongly biased when off target. Flat or weakly informative priors provide protection against an off target prior but are less efficient when the accrual is on target. The accelerated prior performs similar to a strong prior. The hedging prior performs much like the weak priors when the accrual is extremely off target but closer to the strong priors when the accrual is on target or only slightly off target. We suggest improvements in these models and propose new models for future research. Copyright © 2014 John Wiley & Sons, Ltd.
Data-Independent Mass Spectrometry Approach for Screening and Identification of DNA Adducts.
Guo, Jingshu; Villalta, Peter W; Turesky, Robert J
2017-11-07
Long-term exposures to environmental toxicants and endogenous electrophiles are causative factors for human diseases including cancer. DNA adducts reflect the internal exposure to genotoxicants and can serve as biomarkers for risk assessment. Liquid chromatography-multistage mass spectrometry (LC-MS n ) is the most common method for biomonitoring DNA adducts, generally targeting single exposures and measuring up to several adducts. However, the data often provide limited evidence for a role of a chemical in the etiology of cancer. An "untargeted" method is required that captures global exposures to chemicals, by simultaneously detecting their DNA adducts in the genome; some of which may induce cancer-causing mutations. We established a wide selected ion monitoring tandem mass spectrometry (wide-SIM/MS 2 ) screening method utilizing ultraperformance-LC nanoelectrospray ionization Orbitrap MS n with online trapping to enrich bulky, nonpolar adducts. Wide-SIM scan events are followed by MS 2 scans to screen for modified nucleosides by coeluting peaks containing precursor and fragment ions differing by -116.0473 Da, attributed to the neutral loss of deoxyribose. Wide-SIM/MS 2 was shown to be superior in sensitivity, specificity, and breadth of adduct coverage to other tested adductomic methods with detection possible at adduct levels as low as 4 per 10 9 nucleotides. Wide-SIM/MS 2 data can be analyzed in a "targeted" fashion by generation of extracted ion chromatograms or in an "untargeted" fashion where a chromatographic peak-picking algorithm can be used to detect putative DNA adducts. Wide-SIM/MS 2 successfully detected DNA adducts, derived from chemicals in the diet and traditional medicines and from lipid peroxidation products, in human prostate and renal specimens.
Tessonnier, Thomas; Mairani, Andrea; Chen, Wenjing; Sala, Paola; Cerutti, Francesco; Ferrari, Alfredo; Haberer, Thomas; Debus, Jürgen; Parodi, Katia
2018-01-09
Due to their favorable physical and biological properties, helium ion beams are increasingly considered a promising alternative to proton beams for radiation therapy. Hence, this work aims at comparing in-silico the treatment of brain and ocular meningiomas with protons and helium ions, using for the first time a dedicated Monte Carlo (MC) based treatment planning engine (MCTP) thoroughly validated both in terms of physical and biological models. Starting from clinical treatment plans of four patients undergoing proton therapy with a fixed relative biological effectiveness (RBE) of 1.1 and a fraction dose of 1.8 Gy(RBE), new treatment plans were optimized with MCTP for both protons (with variable and fixed RBE) and helium ions (with variable RBE) under the same constraints derived from the initial clinical plans. The resulting dose distributions were dosimetrically compared in terms of dose volume histograms (DVH) parameters for the planning target volume (PTV) and the organs at risk (OARs), as well as dose difference maps. In most of the cases helium ion plans provided a similar PTV coverage as protons with a consistent trend of superior OAR sparing. The latter finding was attributed to the ability of helium ions to offer sharper distal and lateral dose fall-offs, as well as a more favorable differential RBE variation in target and normal tissue. Although more studies are needed to investigate the clinical potential of helium ions for different tumour entities, the results of this work based on an experimentally validated MC engine support the promise of this modality with state-of-the-art pencil beam scanning delivery, especially in case of tumours growing in close proximity of multiple OARs such as meningiomas.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, J; Li, X; Ding, X
Purpose: We performed a retrospective dosimetric comparison study between the robustness optimized Intensity Modulated Proton Therapy (RO-IMPT), volumetric-modulated arc therapy (VMAT), and the non-coplanar 4? intensity modulated radiation therapy (IMRT). These methods represent the most advanced radiation treatment methods clinically available. We compare their dosimetric performance for head and neck cancer treatments with special focus on the OAR sparing near the tumor volumes. Methods: A total of 11 head and neck cases, which include 10 recurrent cases and one bilateral case, were selected for the study. Different dose levels were prescribed to tumor target depending on disease and location. Threemore » treatment plans were created on commercial TPS systems for a novel noncoplanar 4π method (20 beams), VMAT, and RO-IMPT technique (maximum 4 fields). The maximum patient positioning error was set to 3 mm and the maximum proton range uncertainty was set to 3% for the robustness optimization. Line dose profiles were investigated for OARs close to tumor volumes. Results: All three techniques achieved 98% coverage of the CTV target and most photon plans had less than 110% of the hot spots. The RO-IMPT plans show superior tumor dose homogeneity than 4? and VMAT plans. Although RO-IMPT has greater R50 dose spillage to the surrounding normal tissue than 4π and VMAT, the RO-IMPT plans demonstrate better or comparable OAR (parotid, mandible, carotid, oral cavity, pharynx, and etc.) sparing for structures closely abutting tumor targets. Conclusion: The RO-IMPT’s ability of OAR sparing is benchmarked against the C-arm linac based non-coplanar 4π technique and the standard VMAT method. RO-IMPT consistently shows better or comparable OAR sparing even for tissue structures closely abutting treatment target volume. RO-IMPT further reduces treatment uncertainty associated with proton therapy and delivers robust treatment plans to both unilateral and bilateral head and neck cancer patients with desirable treatment time.« less
1983-01-01
soldiers admire and emlate Soviet soldiers ." The overall coverage of Soviet domestic topics and events did not sign- if icantly chapg during January...must be demanding, strict and adhere to the rules of their superior officers. a Soldiers need to work as a team. e Officers must be united when they...decide how strict they should be with their men. e Improve discipline through just punishment. * Soldiers must learn to respect the laws. e Political
Expansion of seasonal influenza vaccination in the Americas
Ropero-Álvarez, Alba María; Kurtis, Hannah J; Danovaro-Holliday, M Carolina; Ruiz-Matus, Cuauhtémoc; Andrus, Jon K
2009-01-01
Background Seasonal influenza is a viral disease whose annual epidemics are estimated to cause three to five million cases of severe illness and 250,000 to 500,000 deaths worldwide. Vaccination is the main strategy for primary prevention. Methods To assess the status of influenza vaccination in the Americas, influenza vaccination data reported to the Pan American Health Organization (PAHO) through 2008 were analyzed. Results Thirty-five countries and territories administered influenza vaccine in their public health sector, compared to 13 countries in 2004. Targeted risk groups varied. Sixteen countries reported coverage among older adults, ranging from 21% to 100%; coverage data were not available for most countries and targeted populations. Some tropical countries used the Northern Hemisphere vaccine formulation and others used the Southern Hemisphere vaccine formulation. In 2008, approximately 166.3 million doses of seasonal influenza vaccine were purchased in the Americas; 30 of 35 countries procured their vaccine through PAHO's Revolving Fund. Conclusion Since 2004 there has been rapid uptake of seasonal influenza vaccine in the Americas. Challenges to fully implement influenza vaccination remain, including difficulties measuring coverage rates, variable vaccine uptake, and limited surveillance and effectiveness data to guide decisions regarding vaccine formulation and timing, especially in tropical countries. PMID:19778430
Simulation environment based on the Universal Verification Methodology
NASA Astrophysics Data System (ADS)
Fiergolski, A.
2017-01-01
Universal Verification Methodology (UVM) is a standardized approach of verifying integrated circuit designs, targeting a Coverage-Driven Verification (CDV). It combines automatic test generation, self-checking testbenches, and coverage metrics to indicate progress in the design verification. The flow of the CDV differs from the traditional directed-testing approach. With the CDV, a testbench developer, by setting the verification goals, starts with an structured plan. Those goals are targeted further by a developed testbench, which generates legal stimuli and sends them to a device under test (DUT). The progress is measured by coverage monitors added to the simulation environment. In this way, the non-exercised functionality can be identified. Moreover, the additional scoreboards indicate undesired DUT behaviour. Such verification environments were developed for three recent ASIC and FPGA projects which have successfully implemented the new work-flow: (1) the CLICpix2 65 nm CMOS hybrid pixel readout ASIC design; (2) the C3PD 180 nm HV-CMOS active sensor ASIC design; (3) the FPGA-based DAQ system of the CLICpix chip. This paper, based on the experience from the above projects, introduces briefly UVM and presents a set of tips and advices applicable at different stages of the verification process-cycle.
Long, S H; Marquis, M S
2001-01-01
Many policy initiatives to increase health insurance coverage would subsidize employers to offer coverage or subsidize employees to participate in their employers' health plans. Using data from the 1997 Robert Wood Johnson Foundation Employer Health Insurance Survey, we contrast "low-wage employers" with all other employers. Employees in low-wage businesses have significantly worse access to employment-based insurance than other employees do; they are less likely to work for an employer that offers insurance, less likely to be eligible if working in a business that offers insurance, and less likely to be enrolled if eligible. Low-wage employers contribute lower shares of premiums and offer less generous benefits than other employers do. Policies that would target subsidies to selected employers to increase insurance offers to low-wage workers are difficult to design, however, because several commonly mentioned employer characteristics (including firm size) are found to be poor indicators of low-wage worker concentration. Programs that would set minimum standards for employer plans to be eligible for "buy-ins" need to base these standards on the less generous terms offered by low-wage employers in order to effectively reach low-wage workers and their dependents.
Selective robust optimization: A new intensity-modulated proton therapy optimization strategy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, Yupeng; Niemela, Perttu; Siljamaki, Sami
2015-08-15
Purpose: To develop a new robust optimization strategy for intensity-modulated proton therapy as an important step in translating robust proton treatment planning from research to clinical applications. Methods: In selective robust optimization, a worst-case-based robust optimization algorithm is extended, and terms of the objective function are selectively computed from either the worst-case dose or the nominal dose. Two lung cancer cases and one head and neck cancer case were used to demonstrate the practical significance of the proposed robust planning strategy. The lung cancer cases had minimal tumor motion less than 5 mm, and, for the demonstration of the methodology,more » are assumed to be static. Results: Selective robust optimization achieved robust clinical target volume (CTV) coverage and at the same time increased nominal planning target volume coverage to 95.8%, compared to the 84.6% coverage achieved with CTV-based robust optimization in one of the lung cases. In the other lung case, the maximum dose in selective robust optimization was lowered from a dose of 131.3% in the CTV-based robust optimization to 113.6%. Selective robust optimization provided robust CTV coverage in the head and neck case, and at the same time improved controls over isodose distribution so that clinical requirements may be readily met. Conclusions: Selective robust optimization may provide the flexibility and capability necessary for meeting various clinical requirements in addition to achieving the required plan robustness in practical proton treatment planning settings.« less
Spiliopoulou, Athina; Colombo, Marco; Orchard, Peter; Agakov, Felix; McKeigue, Paul
2017-01-01
We address the task of genotype imputation to a dense reference panel given genotype likelihoods computed from ultralow coverage sequencing as inputs. In this setting, the data have a high-level of missingness or uncertainty, and are thus more amenable to a probabilistic representation. Most existing imputation algorithms are not well suited for this situation, as they rely on prephasing for computational efficiency, and, without definite genotype calls, the prephasing task becomes computationally expensive. We describe GeneImp, a program for genotype imputation that does not require prephasing and is computationally tractable for whole-genome imputation. GeneImp does not explicitly model recombination, instead it capitalizes on the existence of large reference panels—comprising thousands of reference haplotypes—and assumes that the reference haplotypes can adequately represent the target haplotypes over short regions unaltered. We validate GeneImp based on data from ultralow coverage sequencing (0.5×), and compare its performance to the most recent version of BEAGLE that can perform this task. We show that GeneImp achieves imputation quality very close to that of BEAGLE, using one to two orders of magnitude less time, without an increase in memory complexity. Therefore, GeneImp is the first practical choice for whole-genome imputation to a dense reference panel when prephasing cannot be applied, for instance, in datasets produced via ultralow coverage sequencing. A related future application for GeneImp is whole-genome imputation based on the off-target reads from deep whole-exome sequencing. PMID:28348060
Medicaid Coverage of Tobacco Dependency Treatments | Cancer Trends Progress Report
The Cancer Trends Progress Report, first issued in 2001, summarizes our nation's advances against cancer in relation to Healthy People targets set forth by the Department of Health and Human Services.
VizieR Online Data Catalog: XQ-100 targets equivalent widths (Perrotta+, 2016)
NASA Astrophysics Data System (ADS)
Perrotta, S.; D'Odorico, V.; Prochaska, J. X.; Cristiani, S.; Cupani, G.; Ellison, S.; Lopez, S.; Becker, G. D.; Berg, T. A. M.; Christensen, L.; Denney, K. D.; Hamann, F.; Paris, I.; Vestergaard, M.; Worseck, G.
2018-03-01
The quasars in our sample have been originally selected and observed in a new Legacy Survey, hereafter 'XQ-100', of 100 quasars at emission redshift zem=3.5-4.5 (ESO Large Programme 189.A-0424). The observations have been carried out with X-shooter/VLT (Vernet et al., 2011A&A...536A.105V). The released spectra provide a complete coverage from the atmospheric cut-off to the NIR with a spectral resolution R~6000-9000 depending on wavelength, and a median S/N~30 at the continuum level. XQ-100 provides the first large intermediate-resolution sample of high-redshift quasars with simultaneous rest-frame UV/optical coverage. A full description of the target selection, observations, and data reduction process is presented by Lopez et al. (2016A&A...594A..91L). (2 data files).
Measles elimination in Italy: projected impact of the National Elimination Plan.
Manfredi, P.; Williams, J. R.; Ciofi Degli Atti, M. L.; Salmaso, S.
2005-01-01
A mathematical model was used to evaluate the impact of the Italian Measles National Elimination Plan (NEP), and possible sources of failure in achieving its targets. The model considered two different estimates of force of infection, and the possible effect on measles transmission of the current Italian demographic situation, characterized by a below-replacement fertility. Results suggest that reaching all NEP targets will allow measles elimination to be achieved. In addition, the model suggests that achieving elimination by reaching a 95 % first-dose coverage appears unlikely; and that conducting catch-up activities, reaching high vaccination coverage, could interrupt virus circulation, but could not prevent the infection re-emerging before 2020. Also, the introduction of the second dose of measles vaccine seems necessary for achieving and maintaining elimination. Furthermore, current Italian demography appears to be favourable for reaching elimination. PMID:15724715
Wang, Bu-Hai; Hua, Wei; Gu, Xiang; Wang, Xiao-Lei; Li, Jun; Liu, Li-Qin; Huang, Yu-Xiang
2015-12-01
The purpose of this study was to compare the dosimetric characteristics for hippocampal avoidance (HA) between the treatment plans based on fused CT and MRI imaging during whole brain radiotherapy (WBRT) pertaining to: (1) 3-dimensional conformal radiotherapy (3D-CRT), (2) dynamic intensity modulated radiation therapy (dIMRT), and (3) RapidArc for patients with brain metastases. In our study, HA was defined as hippocampus beyond 5 mm, and planning target volume (PTV) was obtained subtracting HA volume from the volume of whole brain. There were 10 selected patients diagnosed with brain metastases receiving WBRT. These patients received plans for 3D-CRT (two fields), dIMRT (seven non-coplanar fields) and RapidArc (dual arc). The prescribed dose 30 Gy in 10 fractions was delivered to the whole-brain clinical target volume of patients. On the premise of meeting the clinical requirements, we compared target dose distribution, target coverage (TC), homogeneity index (HI), dose of organs at risk (OARs), monitor units (MU) and treatment time between the above three radiotherapy plans. V90 %, V95 % and TC of PTV for 3D-CRT plan were lowest of the three plans. V90 %, V95 % and HI of PTV in RapidArc plan were superior to the other two plans. TC of PTV in RapidArc plan was similar with dIMRT plan (P > 0.05). 3D-CRT was the optimal plan in the three plans for hippocampal protection. The median dose (Dmedian) and the maximum doses (Dmax) of hippocampus in 3D-CRT were 4.95, 10.87 Gy, which were lowest among the three planning approaches (P < 0.05). Dmedian and Dmax of hippocampus in dIMRT were 10.68, 14.11 Gy. Dmedian and Dmax of hippocampus in RapidArc were 10.30 gGy, 13.92 Gy. These parameters of the last two plans pertain to no significant difference (P > 0.05). When WBRT (30 Gy,10F) was equivalent to single dose 2 Gy,NTDmean of hippocampus in 3D-CRT, dIMRT and RapidArc were reduced to 3.60, 8.47, 8.20 Gy2, respectively. In addition, compared with dIMRT, MU of RapidArc was reduced and the treatment time was shortened by nearly 25 %. All three radiotherapy planning approaches in our study can meet the clinical requirements of HA. Although TC in 3D-CRT was lowest, hippocampus was protected best by this plan. So many radiation fields and the design of non-coplanar fields lead to the complication of dIMRT. TC and HI in RapidArc were superior to the other two plans with the precise of meeting the clinical requirements. The difference in protection for hippocampus between dIMRT and RapidArc was statistically significant. In addition, RapidArc can remarkably reduce MU and the treatment time.
Nicolini, Giorgia; Ghosh-Laskar, Sarbani; Shrivastava, Shyam Kishore; Banerjee, Sushovan; Chaudhary, Suresh; Agarwal, Jai Prakash; Munshi, Anusheel; Clivio, Alessandro; Fogliata, Antonella; Mancosu, Pietro; Vanetti, Eugenio; Cozzi, Luca
2012-10-01
A feasibility study was performed to evaluate RapidArc (RA), and the potential benefit of flattening filter-free beams, on advanced esophageal cancer against intensity-modulated radiotherapy (IMRT) and three-dimensional conformal radiotherapy (3D-CRT). The plans for 3D-CRT and IMRT with three to seven and five to seven fixed beams were compared against double-modulated arcs with avoidance sectors to spare the lungs for 10 patients. All plans were optimized for 6-MV photon beams. The RA plans were studied for conventional and flattening filter-free (FFF) beams. The objectives for the planning target volume were the volume receiving ≥ 95% or at most 107% of the prescribed dose of <1% with a dose prescription of 59.4 Gy. For the organs at risk, the lung volume (minus the planning target volume) receiving ≥ 5 Gy was <60%, that receiving 20 Gy was <20%-30%, and the mean lung dose was <15.0 Gy. The heart volume receiving 45 Gy was <20%, volume receiving 30 Gy was <50%. The spinal dose received by 1% was <45 Gy. The technical delivery parameters for RA were assessed to compare the normal and FFF beam characteristics. RA and IMRT provided equivalent coverage and homogeneity, slightly superior to 3D-CRT. The conformity index was 1.2 ± 0.1 for RA and IMRT and 1.5 ± 0.2 for 3D-CRT. The mean lung dose was 12.2 ± 4.5 for IMRT, 11.3 ± 4.6 for RA, and 10.8 ± 4.4 for RA with FFF beams, 18.2 ± 8.5 for 3D-CRT. The percentage of volume receiving ≥ 20 Gy ranged from 23.6% ± 9.1% to 21.1% ± 9.7% for IMRT and RA (FFF beams) and 39.2% ± 17.0% for 3D-CRT. The heart and spine objectives were met by all techniques. The monitor units for IMRT and RA were 457 ± 139, 322 ± 20, and 387 ± 40, respectively. RA with FFF beams showed, compared with RA with normal beams, a ∼20% increase in monitor units per Gray, a 90% increase in the average dose rate, and 20% reduction in beam on time (owing to different gantry speeds). RA demonstrated, compared with conventional IMRT, a similar target coverage and some better dose sparing to the organs at risk; the advantage against conventional 3D-CRT was more evident. RA with FFF beams resulted in minor improvements in plan quality but with the potential for additional useful reduction in the treatment time. Copyright © 2012 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Briscoe, M; Ploquin, N; Voroney, JP
2015-06-15
Purpose: To quantify the effect of patient rotation in stereotactic radiation therapy and establish a threshold where rotational patient set-up errors have a significant impact on target coverage. Methods: To simulate rotational patient set-up errors, a Matlab code was created to rotate the patient dose distribution around the treatment isocentre, located centrally in the lesion, while keeping the structure contours in the original locations on the CT and MRI. Rotations of 1°, 3°, and 5° for each of the pitch, roll, and yaw, as well as simultaneous rotations of 1°, 3°, and 5° around all three axes were applied tomore » two types of brain lesions: brain metastasis and acoustic neuroma. In order to analyze multiple tumour shapes, these plans included small spherical (metastasis), elliptical (acoustic neuroma), and large irregular (metastasis) tumour structures. Dose-volume histograms and planning target volumes were compared between the planned patient positions and those with simulated rotational set-up errors. The RTOG conformity index for patient rotation was also investigated. Results: Examining the tumour volumes that received 80% of the prescription dose in the planned and rotated patient positions showed decreases in prescription dose coverage of up to 2.3%. Conformity indices for treatments with simulated rotational errors showed decreases of up to 3% compared to the original plan. For irregular lesions, degradation of 1% of the target coverage can be seen for rotations as low as 3°. Conclusions: This data shows that for elliptical or spherical targets, rotational patient set-up errors less than 3° around any or all axes do not have a significant impact on the dose delivered to the target volume or the conformity index of the plan. However the same rotational errors would have an impact on plans for irregular tumours.« less
NASA Astrophysics Data System (ADS)
Poulet, L.; Massa, G. D.; Morrow, R. C.; Bourget, C. M.; Wheeler, R. M.; Mitchell, C. A.
2014-07-01
Bioregenerative life-support systems involving photoautotrophic organisms will be necessary to sustain long-duration crewed missions at distant space destinations. Since sufficient sunlight will not always be available for plant growth at many space destinations, efficient electric-lighting solutions are greatly needed. The present study demonstrated that targeted plant lighting with light-emitting diodes (LEDs) and optimizing spectral parameters for close-canopy overhead LED lighting allowed the model crop leaf lettuce (Lactuca sativa L. cv. 'Waldmann's Green') to be grown using significantly less electrical energy than using traditional electric-lighting sources. Lettuce stands were grown hydroponically in a growth chamber controlling temperature, relative humidity, and CO2 level. Several red:blue ratios were tested for growth rate during the lag phase of lettuce growth. In addition, start of the exponential growth phase was evaluated. Following establishment of a 95% red + 5% blue spectral balance giving the best growth response, the energy efficiency of a targeted lighting system was compared with that of two total coverage (untargeted) LED lighting systems throughout a crop-production cycle, one using the same proportion of red and blue LEDs and the other using white LEDs. At the end of each cropping cycle, whole-plant fresh and dry mass and leaf area were measured and correlated with the amount of electrical energy (kWh) consumed for crop lighting. Lettuce crops grown with targeted red + blue LED lighting used 50% less energy per unit dry biomass accumulated, and the total coverage white LEDs used 32% less energy per unit dry biomass accumulated than did the total coverage red + blue LEDs. An energy-conversion efficiency of less than 1 kWh/g dry biomass is possible using targeted close-canopy LED lighting with spectral optimization. This project was supported by NASA grant NNX09AL99G.
Bazán, Magdalena; Villacorta, Erika; Barbagelatta, Gisella; Jimenez, M Michelle; Goya, Cecilia; Bartolini, Rosario M; Penny, Mary E
2017-05-19
Vaccination against seasonal influenza in health workers is recommended but coverage is variable. This study aimed to determine coverage of influenza vaccination among health workers in Lima, Peru in 2010; explore barriers and enabling elements for vaccination; and suggest strategies to improve coverage. Qualitative interviews informed the development of a survey instrument that consisted of open and close-ended questions. Sub-analyses were done by occupational group and results were calculated as percentages for each possible response with confidence intervals of 95%. Coverage of the influenza vaccination was 77.2%. Vaccinated staff were less likely to have permanent contracts (p=0.0150) and vaccination coverage was lower in physicians (p=0.0001). Over 90% cited protection of themselves, families and patients as reasons for vaccination and 48% mentioned peer encouragement. Fear of adverse events (47%) and organizational barriers (>30%) were reasons for non-vaccination. To improve coverage, highest priority was given to strategies providing more information. Key factors in driving health worker vaccination include desire for protection and peer encouragement. Perceptual barriers based on a misunderstanding of the epidemiology of influenza and vaccination could be overcome by targeted education and information. Organizational barriers require attention to how vaccination is implemented within health facilities. Copyright © 2017 Elsevier Ltd. All rights reserved.