NASA Astrophysics Data System (ADS)
Grach, S. M.; Klimenko, V. V.; Shindin, A. V.; Nasyrov, I. A.; Sergeev, E. N.; A. Yashnov, V.; A. Pogorelko, N.
2012-06-01
We present the results of studying the structure and dynamics of the HF-heated volume above the Sura facility obtained in 2010 by measurements of ionospheric airglow in the red (λ = 630 nm) and green (λ = 557.7 nm) lines of atomic oxygen. Vertical sounding of the ionosphere (followed by modeling of the pump-wave propagation) and measurements of stimulated electromagnetic emission were used for additional diagnostics of ionospheric parameters and the processes occurring in the heated volume.
NASA Astrophysics Data System (ADS)
Belov, Alexey; Huba, J. D.
indent=1cm We present the results of numerical simulation of the near-Earth plasma disturbances produced by resonant heating of the ionospheric F-region by high-power HF radio emission from the SURA facility. The computational model is based on the modified version of the SAMI2 code (release 1.00). The model input parameters are appropriated to the conditions of the SURA-DEMETER experiment. In this work, we study the spatial structure and temporal characteristics of stimulated large-scale disturbances of the electron number density and temperature. It is shown that the stimulated disturbances are observed throughout the ionosphere. Disturbances are recorded both in the region below the pump wave reflection level and in the outer ionosphere (up to 3000 km). At the DEMETER altitude, an increase in the ion number density is stipulated by the oxygen ions O (+) , whereas the number density of lighter H (+) ions decreases. A typical time of the formation of large-scale plasma density disturbances in the outer ionosphere is 2-3 min. After the heater is turned off, the disturbances relaxation time is approximately 30 min. The simulation results are important for planning future promising experiments on the formation of ionospheric artificial density ducts. This work was supported by the Russian Foundation for Basic Research (project No. 12-02-00747-a), and the Government of the Russian Federation (contract No. 14.B25.31.0008).
Siegler, Jason C; Mudie, Kurt; Marshall, Paul
2016-11-01
What is the central question of this study? Does metabolic alkalosis in humans, induced by sodium bicarbonate, affect rates of skeletal muscle fatigue differentially in muscle groups composed predominately of slow- and fast-twitch fibres? What is the main finding and its importance? Sodium bicarbonate exhibited no effect on the fatigue profile observed between triceps surae and brachii muscle groups during and after 2 min of tetanic stimulation. For the first time in exercising humans, we have profiled the effect of sodium bicarbonate on the voluntary and involuntary contractile characteristics of muscle groups representative of predominately slow- and fast-twitch fibres. The effect of metabolic alkalosis on fibre-specific maximal force production and rates of force development (RFD) has been investigated previously in animal models, with evidence suggesting an improved capacity to develop force rapidly in fast- compared with slow-twitch muscle. We have attempted to model in vivo the fatigue profile of voluntary and involuntary maximal force and RFD in the triceps surae and brachii after sodium bicarbonate (NaHCO 3 ) ingestion. In a double-blind, three-way repeated-measures design, participants (n = 10) ingested either 0.3 g kg -1 NaHCO 3 (ALK) or equivalent calcium carbonate (PLA) prior to 2 min of continuous (1 Hz) supramaximal stimulation (300 ms at 40 Hz) of the triceps surae or brachii, with maximal voluntary efforts (maximal voluntary torque) coupled with direct muscle stimulation also measured at baseline, 1 and 2 min. Metabolic alkalosis was achieved in both ALK trials but was not different between muscle groups. Regardless of the conditions, involuntary torque declined nearly 60% in the triceps brachii (P < 0.001) and ∼30% in the triceps surae (P < 0.001). In all trials, there was a significant decline in normalized involuntary RFD (P < 0.05). Maximal voluntary torque declined nearly 28% but was not different between conditions (P < 0.01), and although declining nearly 21% in voluntary RFD (P < 0.05) there was no difference between PLA and ALK in either muscle group (P = 0.93). Sodium bicarbonate exhibited no effect on the fatigue observed between representative fibre-type muscle groups on maximal voluntary and involuntary torque or rates of torque development during and after 2 min of tetanic stimulation. © 2016 The Authors. Experimental Physiology © 2016 The Physiological Society.
Pingel, Jessica; Wienecke, Jacob; Lorentzen, Jakob
2016-01-01
Botulinum toxin is used with the intention of diminishing spasticity and reducing the risk of development of contractures. Here, we investigated changes in muscle stiffness caused by reflex activity or elastic muscle properties following botulinum toxin injection in the triceps surae muscle in rats. Forty-four rats received injection of botulinum toxin in the left triceps surae muscle. Control measurements were performed on the noninjected contralateral side in all rats. Acute experiments were performed, 1, 2, 4, and 8 wk following injection. The triceps surae muscle was dissected free, and the Achilles tendon was cut and attached to a muscle puller. The resistance of the muscle to stretches of different amplitudes and velocities was systematically investigated. Reflex-mediated torque was normalized to the maximal muscle force evoked by supramaximal stimulation of the tibial nerve. Botulinum toxin injection caused severe atrophy of the triceps surae muscle at all time points. The force generated by stretch reflex activity was also strongly diminished but not to the same extent as the maximal muscle force at 2 and 4 wk, signifying a relative reflex hyperexcitability. Passive muscle stiffness was unaltered at 1 wk but increased at 2, 4, and 8 wk (P < 0.01). These data demonstrate that botulinum toxin causes a relative increase in reflex stiffness, which is likely caused by compensatory neuroplastic changes. The stiffness of elastic elements in the muscles also increased. The data are not consistent with the ideas that botulinum toxin is an efficient antispastic medication or that it may prevent development of contractures. PMID:27628204
Recording and assessment of evoked potentials with electrode arrays.
Miljković, N; Malešević, N; Kojić, V; Bijelić, G; Keller, T; Popović, D B
2015-09-01
In order to optimize procedure for the assessment of evoked potentials and to provide visualization of the flow of action potentials along the motor systems, we introduced array electrodes for stimulation and recording and developed software for the analysis of the recordings. The system uses a stimulator connected to an electrode array for the generation of evoked potentials, an electrode array connected to the amplifier, A/D converter and computer for the recording of evoked potentials, and a dedicated software application. The method has been tested for the assessment of the H-reflex on the triceps surae muscle in six healthy humans. The electrode array with 16 pads was positioned over the posterior aspect of the thigh, while the recording electrode array with 16 pads was positioned over the triceps surae muscle. The stimulator activated all the pads of the stimulation electrode array asynchronously, while the signals were recorded continuously at all the recording sites. The results are topography maps (spatial distribution of evoked potentials) and matrices (spatial visualization of nerve excitability). The software allows the automatic selection of the lowest stimulation intensity to achieve maximal H-reflex amplitude and selection of the recording/stimulation pads according to predefined criteria. The analysis of results shows that the method provides rich information compared with the conventional recording of the H-reflex with regard the spatial distribution.
Sura heating facility transmissions to the CASSIOPE/e-POP satellite
NASA Astrophysics Data System (ADS)
James, H. G.; Frolov, V. L.; Andreeva, E. S.; Padokhin, A. M.; Siefring, C. L.
2017-02-01
Throughout a nighttime pass of the CASSIOPE satellite at an altitude of about 1300 km above the Sura heating facility, transmission of O-mode radiation from Sura to the enhanced Polar Outflow Probe (e-POP) Radio Receiver Instrument on CASSIOPE was maintained. Also, during this pass, continuous VHF/UHF transmission from the e-POP Coherent Electromagnetic Radio Tomography radio beacon to three coordinated ground receivers in the Sura vicinity was achieved. Tomography of the VHF/UHF received wave data based on total electron content permitted the two-dimensional distribution of ionospheric ambient electron plasma frequency fpe to be determined in the latitude-altitude space between Sura and CASSIOPE. The foF2 values about 0.1 MHz above the Sura pump frequency of 4.3 MHz were measured by the tomography. We examine the question of whether the observations can be explained on the basis of classic propagation in a smooth ionosphere. Tracing of rays from Sura toward CASSIOPE orbital locations finds most rays reflected away from the topside by the patchy ionospheric structure in bottomside fpe. It is concluded that O-mode ducting in underdense field-aligned irregularities is responsible for maintaining the transionospheric transmission across the 2 min pass. O- to Z-mode "radio-window" conversion in the F region bottomside is not required to explain these data.
Pingel, Jessica; Wienecke, Jacob; Lorentzen, Jakob; Nielsen, Jens Bo
2016-12-01
Botulinum toxin is used with the intention of diminishing spasticity and reducing the risk of development of contractures. Here, we investigated changes in muscle stiffness caused by reflex activity or elastic muscle properties following botulinum toxin injection in the triceps surae muscle in rats. Forty-four rats received injection of botulinum toxin in the left triceps surae muscle. Control measurements were performed on the noninjected contralateral side in all rats. Acute experiments were performed, 1, 2, 4, and 8 wk following injection. The triceps surae muscle was dissected free, and the Achilles tendon was cut and attached to a muscle puller. The resistance of the muscle to stretches of different amplitudes and velocities was systematically investigated. Reflex-mediated torque was normalized to the maximal muscle force evoked by supramaximal stimulation of the tibial nerve. Botulinum toxin injection caused severe atrophy of the triceps surae muscle at all time points. The force generated by stretch reflex activity was also strongly diminished but not to the same extent as the maximal muscle force at 2 and 4 wk, signifying a relative reflex hyperexcitability. Passive muscle stiffness was unaltered at 1 wk but increased at 2, 4, and 8 wk (P < 0.01). These data demonstrate that botulinum toxin causes a relative increase in reflex stiffness, which is likely caused by compensatory neuroplastic changes. The stiffness of elastic elements in the muscles also increased. The data are not consistent with the ideas that botulinum toxin is an efficient antispastic medication or that it may prevent development of contractures. Copyright © 2016 the American Physiological Society.
Stackhouse, Scott K.; Binder-Macleod, Stuart A.; Stackhouse, Carrie A.; McCarthy, James J.; Prosser, Laura A.; Lee, Samuel C. K.
2011-01-01
Background To date, no reports have investigated neuromuscular electrical stimulation (NMES) to increase muscle force production of children with cerebral palsy (CP) using high-force contractions and low repetitions. Objective The aims of this study were to determine if isometric NMES or volitional training in children with CP could increase muscle strength and walking speed and to examine the mechanisms that may contribute to increased force production. Methods Eleven children with spastic diplegia were assigned to an NMES training group or to a volitional training group. Participants in the NMES group had electrodes implanted percutaneously to activate the quadriceps femoris and triceps surae muscles. The volitional group trained with maximal effort contractions. Both groups performed a 12-week isometric strength-training program. Maximum voluntary isometric contract ion (MVIC) force, voluntary muscle activation, quadriceps and triceps surae cross-sectional area (CSA), and walking speed were measured pre- and post-strength training. Results The NMES-trained group had greater increases in normalized force production for both die quadriceps femoris and triceps surae. Similarly only the NMES group showed an increase in walking speed after training. Changes in voluntary muscle activation explained approximately 67% and 37% of the changes seen in the MVIC of the NMES and volitional groups, respectively. Quadriceps femoris maximum CSA increased significantly for the NMES group only. Conclusions This study was the first to quantitatively show strength gains with the use of NMES in children with CP. These results support the need for future experimental studies that will examine the clinical effectiveness of NMES strength training. PMID:17369515
Muscular contraction stimulates posterior hypothalamic neurons.
Waldrop, T G; Stremel, R W
1989-02-01
Recent studies have suggested that the subthalamic locomotor region (STLR) of the posterior hypothalamus is involved in modulating cardiorespiratory responses to feedback from contracting muscles. The purpose of this study was to determine whether neurons in this hypothalamic region alter their discharge frequency during contraction of hindlimb muscles. Stainless steel electrodes were used to record single-unit activity of STLR neurons during static and rhythmic contractions of hindlimb muscles in anesthetized cats. Recordings were also made from neurons in areas outside but surrounding the subthalamic locomotor region. Contraction of the triceps surae muscles was induced by stimulation of the peripheral cut ends of the L7 and S1 ventral roots. Both static and rhythmic contractions of the triceps surae evoked an increase in the discharge rate of the majority of the STLR cells studied. Two types of excitatory responses were observed: 1) abrupt increases in discharge frequency at the onset of muscular contraction and 2) a delayed more gradual increase in firing. Most of the cells that responded to muscular contraction could be activated by mechanical probing of the triceps surae muscles. However, the changes in discharge frequency were unrelated to changes in arterial pressure occurring during muscular contraction. Most of the neurons located outside the STLR were slightly inhibited by or did not respond to muscular contraction. Thus input from contracting muscles exerts predominantly an excitatory effect on neurons in the posterior hypothalamus. These results are consistent with other studies which have concluded that this hypothalamic site is involved in influencing the cardiorespiratory responses to muscular contraction.
NASA Astrophysics Data System (ADS)
James, H. G.; Frolov, V. L.; Padokhin, A. M.; Siefring, C. L.
2015-12-01
High-frequency pump waves have been transmitted from the Russian heating facility Sura to the Radio Receiver Instrument (RRI) in the e-POP payload on the Canadian small satellite CASSIOPE. This experiment has been carried out 24 times, under a variety of circumstances. In some cases, the ePOP VHF-UHF beacon CERTO was on, and ground receivers near Sura recorded total electron content. Subsequent tomographic processing has allowed the two-dimensional electron density distribution to be determined in the altitude-latitude space between Sura and CASSIOPE. We present some details from a night-time pass on 9 Sept. 2014 when the fixed pump frequency 4.3 MHz was slightly smaller than foF2 above Sura. This was an instance in which conversion between the O and Z cold plasma modes may have been required to achieve transmission. Explanation could be elaborated in terms of underdense, heater-created, field-aligned irregularities that are "artificial radio windows". The Sura heater radiation pattern maximum was tilted 12° south of the vertical, toward the terrestrial magnetic field axis, potentially enhancing the power transmitted through radio windows. The observations are interpreted in the light of competing concepts of transmission.
A comparative study of two-piece ostomy appliances.
Welser, Marion; Riedlinger, Inge; Prause, Ulla
The quality of life of people with a stoma may be affected by peristomal skin disorders and by frequent unplanned changes of ostomy appliances due to problems with those appliances. The aim of this study was to evaluate two new, two-piece ostomy appliances with mechanical couplings (both from the SenSura range by Coloplast) and their ability to address areas that may be important to the quality of life of people with stomas, including appliance changes, stool seepage and overfilling. The study design featured two comparative, crossover, randomized multi-centre studies that were conducted in Germany. The SenSura appliances were evaluated against established reference appliances. Seventy-three individuals with a colostomy (closed-end appliances) and 75 individuals with an ileostomy (drainable appliances) participated in the studies. The participants tested 4-6 flanges of each type within a maximum period of two weeks. The results demonstrated that there was less seepage of stool observed under the SenSura flange when it was removed (p<0.05). Also, there were fewer unplanned changes (p<0.0005) seen with SenSura than with the reference appliances. The SenSura flanges had better adhesion and flexibility and were easier to remove than the references (p<0.0005), and they had greater resistance to erosion (p<0.05). In conclusion, SenSura performed better than the reference appliances on quality of life indicators - there were fewer unplanned changes and less seepage of stool was observed in patients using the SenSura products.
DiDomenico, Angela; Hedin, Marshal
2016-01-01
The western United States is home to numerous narrowly endemic harvestman taxa (Arachnida, Opiliones), including members of the genus Sitalcina Banks, 1911. Sitalcina is comprised of three species groups, including the monospecific Sitalcina californica and Sitalcina lobata groups, and the Sitalcina sura group with eight described species. All species in the Sitalcina sura group have very small geographic distributions, with group members distributed like disjunct "beads on a string" from Monterey south to southern California and southeast to the sky-island mountain ranges of southern Arizona. Here, molecular phylogenetic and species delimitation analyses were conducted for all described species in the Sitalcina sura group, plus several newly discovered populations. Species trees were reconstructed using multispecies coalescent methods implemented in *BEAST, and species delimitation was accomplished using Bayes Factor Delimitation (BFD). Based on quantitative species delimitation results supported by consideration of morphological characters, two new species (Sitalcina oasiensis sp. n., Sitalcina ubicki sp. n.) are described. We also provide a description of the previously unknown male of Sitalcina borregoensis Briggs, 1968. Molecular phylogenetic evidence strongly supports distinctive desert versus coastal clades, with desert canyon taxa from southern California more closely related to Arizona taxa than to geographically proximate California coastal taxa. We hypothesize that southern ancestry and plate tectonics have played a role in the diversification history of this animal lineage, similar to sclerophyllous plant taxa of the Madro-Tertiary Geoflora. Molecular clock analyses for the Sitalcina sura group are generally consistent with these hypotheses. We also propose that additional Sitalcina species await discovery in the desert canyons of southern California and northern Baja, and the mountains of northwestern mainland Mexico.
DiDomenico, Angela; Hedin, Marshal
2016-01-01
Abstract The western United States is home to numerous narrowly endemic harvestman taxa (Arachnida, Opiliones), including members of the genus Sitalcina Banks, 1911. Sitalcina is comprised of three species groups, including the monospecific Sitalcina californica and Sitalcina lobata groups, and the Sitalcina sura group with eight described species. All species in the Sitalcina sura group have very small geographic distributions, with group members distributed like disjunct “beads on a string” from Monterey south to southern California and southeast to the sky-island mountain ranges of southern Arizona. Here, molecular phylogenetic and species delimitation analyses were conducted for all described species in the Sitalcina sura group, plus several newly discovered populations. Species trees were reconstructed using multispecies coalescent methods implemented in *BEAST, and species delimitation was accomplished using Bayes Factor Delimitation (BFD). Based on quantitative species delimitation results supported by consideration of morphological characters, two new species (Sitalcina oasiensis sp. n., Sitalcina ubicki sp. n.) are described. We also provide a description of the previously unknown male of Sitalcina borregoensis Briggs, 1968. Molecular phylogenetic evidence strongly supports distinctive desert versus coastal clades, with desert canyon taxa from southern California more closely related to Arizona taxa than to geographically proximate California coastal taxa. We hypothesize that southern ancestry and plate tectonics have played a role in the diversification history of this animal lineage, similar to sclerophyllous plant taxa of the Madro-Tertiary Geoflora. Molecular clock analyses for the Sitalcina sura group are generally consistent with these hypotheses. We also propose that additional Sitalcina species await discovery in the desert canyons of southern California and northern Baja, and the mountains of northwestern mainland Mexico. PMID:27199607
SOMA AS ENERGIZER-CUM-EUPHORIANT, VERSUS SURA, AN INTOXICANT
Mahdihassan, S.
1984-01-01
Specific features of Soma plant are implict from various references in Rigveda enabling its identity as ephedra. Its juice is an energizer – cum – euphoriant contrary to the intoxicant sura. Sura is beer prepared from barely malt. Soma is the juice of ephedra rich in ephedrine which is antisomnalent. At least one use of soma has never been substituted, as the drink of longevity for a newly born child. PMID:22557400
Muscle activation and the isokinetic torque-velocity relationship of the human triceps surae.
Harridge, S D; White, M J
1993-01-01
The influence of muscle activation and the time allowed for torque generation on the angle-specific torque-velocity relationship of the triceps surae was studied during plantar flexion using supramaximal electrical stimulation and a release technique on six male subjects [mean (SD) age 25 (4) years]. Torque-velocity data were obtained under different levels of constant muscle activation by varying the stimulus frequency and the time allowed for isometric torque generation prior to release and isokinetic shortening. To eliminate the effects of the frequency response on absolute torque the isokinetic data were normalized to the maximum isometric torque values at 0.44 rad. There were no significant differences in the normalized torques generated at any angular velocity using stimulus frequencies of 20, 50 or 80 Hz. When the muscle was stimulated at 50 Hz the torques obtained after a 400 ms and 1 s pre-release isometric contraction did not differ significantly. However, with no pre-release contraction significantly less torque was generated at all angular velocities beyond 1.05 rad.s-1 when compared with either the 200, 400 ms or 1 s condition. With a 200 ms pre-release contraction significantly less torque was generated at angular velocities beyond 1.05 rad.s-1 when compared with the 400 ms or 1 s conditions. It would seem that the major factor governing the shape of the torque-velocity curve at a constant level of muscle activation is the time allowed for torque generation.
Magown, Philippe; Shettar, Basavaraj; Zhang, Ying; Rafuse, Victor F.
2015-01-01
Neural prostheses can restore meaningful function to paralysed muscles by electrically stimulating innervating motor axons, but fail when muscles are completely denervated, as seen in amyotrophic lateral sclerosis, or after a peripheral nerve or spinal cord injury. Here we show that channelrhodopsin-2 is expressed within the sarcolemma and T-tubules of skeletal muscle fibres in transgenic mice. This expression pattern allows for optical control of muscle contraction with comparable forces to nerve stimulation. Force can be controlled by varying light pulse intensity, duration or frequency. Light-stimulated muscle fibres depolarize proportionally to light intensity and duration. Denervated triceps surae muscles transcutaneously stimulated optically on a daily basis for 10 days show a significant attenuation in atrophy resulting in significantly greater contractile forces compared with chronically denervated muscles. Together, this study shows that channelrhodopsin-2/H134R can be used to restore function to permanently denervated muscles and reduce pathophysiological changes associated with denervation pathologies. PMID:26460719
2006-09-30
coastal phenomena. OBJECTIVES SURA is creating a SCOOP “Grid” that extends the interoperability enabled by the World Wide Web. The coastal ... community faces special challenges with respect to achieving a level of interoperability that can leverage emerging Grid technologies. With that in mind
Freundl, Brigitta; Binder, Heinrich; Minassian, Karen
2018-01-01
Epidural electrical stimulation of the lumbar spinal cord is currently regaining momentum as a neuromodulation intervention in spinal cord injury (SCI) to modify dysregulated sensorimotor functions and augment residual motor capacity. There is ample evidence that it engages spinal circuits through the electrical stimulation of large-to-medium diameter afferent fibers within lumbar and upper sacral posterior roots. Recent pilot studies suggested that the surface electrode-based method of transcutaneous spinal cord stimulation (SCS) may produce similar neuromodulatory effects as caused by epidural SCS. Neurophysiological and computer modeling studies proposed that this noninvasive technique stimulates posterior-root fibers as well, likely activating similar input structures to the spinal cord as epidural stimulation. Here, we add a yet missing piece of evidence substantiating this assumption. We conducted in-depth analyses and direct comparisons of the electromyographic (EMG) characteristics of short-latency responses in multiple leg muscles to both stimulation techniques derived from ten individuals with SCI each. Post-activation depression of responses evoked by paired pulses applied either epidurally or transcutaneously confirmed the reflex nature of the responses. The muscle responses to both techniques had the same latencies, EMG peak-to-peak amplitudes, and waveforms, except for smaller responses with shorter onset latencies in the triceps surae muscle group and shorter offsets of the responses in the biceps femoris muscle during epidural stimulation. Responses obtained in three subjects tested with both methods at different time points had near-identical waveforms per muscle group as well as same onset latencies. The present results strongly corroborate the activation of common neural input structures to the lumbar spinal cord—predominantly primary afferent fibers within multiple posterior roots—by both techniques and add to unraveling the basic mechanisms underlying electrical SCS. PMID:29381748
Provost, Clement P; Tasseel-Ponche, Sophie; Lozeron, Pierre; Piccinini, Giulia; Quintaine, Victorine; Arnulf, Bertrand; Kubis, Nathalie; Yelnik, Alain P
2018-02-28
To investigate the weight of visual and proprioceptive inputs, measured indirectly in standing position control, in patients with chronic acquired demyelinating polyneuropathy (CADP). Prospective case study. Twenty-five patients with CADP and 25 healthy controls. Posture was recorded on a double force platform. Stimulations were optokinetic (60°/s) for visual input and vibration (50 Hz) for proprioceptive input. Visual stimulation involved 4 tests (upward, downward, rightward and leftward) and proprioceptive stimulation 2 tests (triceps surae and tibialis anterior). A composite score, previously published and slightly modified, was used for the recorded postural signals from the different stimulations. Despite their sensitivity deficits, patients with CADP were more sensitive to proprioceptive stimuli than were healthy controls (mean composite score 13.9 ((standard deviation; SD) 4.8) vs 18.4 (SD 4.8), p = 0.002). As expected, they were also more sensitive to visual stimuli (mean composite score 10.5 (SD 8.7) vs 22.9 (SD 7.5), p <0.0001). These results encourage balance rehabilitation of patients with CADP, aimed at promoting the use of proprioceptive information, thereby reducing too-early development of visual compensation while proprioception is still available.
Evidence for intermuscle difference in slack angle in human triceps surae.
Hirata, Kosuke; Kanehisa, Hiroaki; Miyamoto-Mikami, Eri; Miyamoto, Naokazu
2015-04-13
This study examined whether the slack angle (i.e., the joint angle corresponding to the slack length) varies among the synergists of the human triceps surae in vivo. By using ultrasound shear wave elastography, shear modulus of each muscle of the triceps surae was measured during passive stretching from 50° of plantar flexion in the knee extended position at an angular velocity of 1°/s in 9 healthy adult subjects. The slack angle of each muscle was determined from the ankle joint angle-shear modulus relationship as the first increase in shear modulus. The slack angle was significantly greater in the medial gastrocnemius (20.7±6.7° plantarflexed position) than in the lateral gastrocnemius (14.9±6.7° plantarflexed position) and soleus (2.0±4.8° dorsiflexed position) and greater in the lateral gastrocnemius than in the soleus. This study provided evidence that the slack angle differs among the triceps surae; the medial gastrocnemius produced passive force at the most plantarflexed position while the slack angle of the soleus was the most dorsiflexed position. Copyright © 2015 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Bogden, P.; Partners, S.
2008-12-01
The Web 2.0 has helped globalize the economy and change social interactions, but the full impact on coastal sciences has yet to be realized. The SCOOP program (www.OpenIOOS.org/about/sura.html), an initiative of the Coastal Research Committee of the Southeastern Universities Research Association (SURA), has been using Web 2.0 technologies to create infrastructure for a multi-disciplinary Distributed Coastal Laboratory (DCL). In the spirit of the Web 2.0, SCOOP strives to provide an open-access virtual facility where "virtual visiting" scientists can log in, perform experiments (e.g., evaluate new wetting/drying algorithms in several different inundation models), potentially contribute to the assembly of resources (e.g., leave their algorithms for others), and then move on. The SCOOP prototype has focused on storm surge and waves (the initial science focus), and integrates a real-time data network to evaluate the predictions. The multi-purpose SCOOP components support a sensor-web initiative (www.OOSTethys.org) that is co-led by SURA. SCOOP also includes portals with real-time visualization, workflow configuration and decision-tool prototypes (www.OpenIOOS.org), powered by distributed computing resources from multiple universities across the nation (www.sura.org/SURAgrid). Based on our experience, we propose three key ingredients for initiatives to have the biggest impact on coastal science: (1) standards, (2) working prototypes and (3) communities of interest. We strongly endorse the Open Geospatial Consortium - a geospatial analog of the World Wide Web consortium - and other international consensus-standards bodies that engage government, private sector and academic involvement. But these standards are often highly complex, which can be an impediment to their use. We have overcome such hurdles with the second key ingredient: a focused working prototype. The prototype should include guides and resources that make it easy for others to apply, test, and revise the prototype, all without need to understand the standards in their overwhelming complexity. In addition, the prototype should support direct involvement of the third key ingredient: communities of interest that assess functional relevance. We expect that any two of these ingredients alone, without the third, will severely limit applicability and impact of any initiative.
The lower ionosphere response to its disturbances by powerful radio waves
NASA Astrophysics Data System (ADS)
Bakhmetieva, N. V.; Frolov, V. L.; Vyakhirev, V. D.; Kalinina, E. E.; Akchurin, A. D.; Zykov, E. Yu.
2018-04-01
The paper presents data from some campaigns at Sura heating facility in 2011-1016. The experiments on probing of the artificial disturbed region of the lower ionosphere were carried out at two observation sites. One of them was located near Vasil'sursk 1 km from Sura facility (56.1°N; 46.1°E) and the other site was located at the Observatory (55.85°N; 48.8°E) of Kazan State University, 170 km to the East. Investigation of the features of the disturbed region of the lower ionosphere based on its diagnostics by the methods of the vertical sounding and oblique backscattering is the main goal of this paper. Ionosphere disturbance was fulfilled by the effect of the powerful radio wave of the ordinary or extraordinary polarization emitted by transmitters of the Sura facility with effective radiated power ERP = 50-120 MW at the frequency of 4.3, 4.7 and 5.6 MHz. Pumping waves were emitted with period from 30 s to 15 min. The disturbed region of the ionosphere in Vasil'sursk was probed by the vertical sounding technique using the partial reflexion radar at the frequency of 2.95 and 4.7 MHz. For the oblique sounding of the disturbed region the modified ionosonde Cyclon-M, operating at ten frequencies from 2.01 to 6.51 MHz was used at the Observatory site. On many heating sessions simultaneous variations of the probing partial reflection signals in Vasil'sursk and backscattered signals in Observatory were observed at the height at 40-100 km below the reflection height of the pumping wave. These observations were correlated with the pumping periods of the Sura facility. Possible mechanisms of the appearance of the disturbance in the lower ionosphere and its effect on the probing radio waves are discussed.
Reciprocal inhibition between motor neurons of the tibialis anterior and triceps surae in humans.
Yavuz, Utku Ş; Negro, Francesco; Diedrichs, Robin; Farina, Dario
2018-05-01
Motor neurons innervating antagonist muscles receive reciprocal inhibitory afferent inputs to facilitate the joint movement in the two directions. The present study investigates the mutual transmission of reciprocal inhibitory afferent inputs between the tibialis anterior (TA) and triceps surae (soleus and medial gastrocnemius) motor units. We assessed this mutual mechanism in large populations of motor units for building a statistical distribution of the inhibition amplitudes during standardized input to the motor neuron pools to minimize the effect of modulatory pathways. Single motor unit activities were identified using high-density surface electromyography (HDsEMG) recorded from the TA, soleus (Sol), and medial gastrocnemius (GM) muscles during isometric dorsi- and plantarflexion. Reciprocal inhibition on the antagonist muscle was elicited by electrical stimulation of the tibial (TN) or common peroneal nerves (CPN). The probability density distributions of reflex strength for each muscle were estimated to examine the strength of mutual transmission of reciprocal inhibitory input. The results showed that the strength of reciprocal inhibition in the TA motor units was fourfold greater than for the GM and the Sol motor units. This suggests an asymmetric transmission of reciprocal inhibition between ankle extensor and flexor muscles. This asymmetry cannot be explained by differences in motor unit type composition between the investigated muscles since we sampled low-threshold motor units in all cases. Therefore, the differences observed for the strength of inhibition are presumably due to a differential reciprocal spindle afferent input and the relative contribution of nonreciprocal inhibitory pathways. NEW & NOTEWORTHY We investigated the mutual transmission of reciprocal inhibition in large samples of motor units using a standardized input (electrical stimulation) to the motor neurons. The results demonstrated that the disynaptic reciprocal inhibition exerted between ankle flexor and extensor muscles is asymmetric. The functional implication of asymmetric transmission may be associated with the neural strategies of postural control.
Substance P release in the spinal cord during the exercise pressor reflex in anaesthetized cats.
Wilson, L B; Fuchs, I E; Matsukawa, K; Mitchell, J H; Wall, P T
1993-01-01
1. The purpose of this study was to determine if static skeletal muscle contraction causes the release of substance P(SP) in the L7-dorsal horn region of the spinal cord. A laminectomy was performed to expose the spinal cord of alpha-chloralose anaesthetized cats. The L6 spinal root was cut. A microdialysis probe was inserted into the L7 dorsal horn region ipsilateral to the contracting triceps surae muscle. The probe was perfused with a buffer solution at 3 microliters/min. Substance P-like immunoreactivity (SP-LI) was measured, from the microdialysis samples, by radioimmunoassay. 2. A 5-9 min contraction of the triceps surae muscle was evoked by alternate electrical stimulation of the peripheral ends of the cut L7 and S1 ventral roots. Basal SP-LI release was 0.20 +/- 0.03 fmol/100 microliters and was increased to 0.54 +/- 0.05 fmol/100 microliters (mean +/- S.D.) by static muscle contraction. This increase was greatly attenuated after cutting the L7 and S1 dorsal roots (0.23 +/- 0.03 to 0.39 +/- 0.08 fmol/100 microliters) or completely abolished by muscle paralysis (0.27 +/- 0.03 to 0.31 +/- 0.01 fmol/100 microliters). Muscle contraction also increased mean arterial blood pressure (MAP) 29 +/- 20 mmHg and heart rate (HR) 11 +/- 5 beats/min (mean +/- S.D.). These cardiovascular changes to muscle contraction were abolished by sectioning the dorsal roots or when the ventral roots were electrically stimulated after the cats were paralysed. 3. These results demonstrate that static contraction of skeletal muscle increases the release of SP-LI in the dorsal horn of the spinal cord. Furthermore, these data support the hypothesis that SP plays a role in mediating the cardiovascular responses evoked during static exercise. PMID:7683719
Wang, Yan; Wang, Rui; Jin, Feng; Liu, Yang; Yu, Jiayu; Fu, Xinmiao; Chang, Zengyi
2016-08-05
β-barrel outer membrane proteins (OMPs) are ubiquitously present in Gram-negative bacteria, mitochondria and chloroplasts, and function in a variety of biological processes. The mechanism by which the hydrophobic nascent β-barrel OMPs are transported through the hydrophilic periplasmic space in bacterial cells remains elusive. Here, mainly via unnatural amino acid-mediated in vivo photo-crosslinking studies, we revealed that the primary periplasmic chaperone SurA interacts with nascent β-barrel OMPs largely via its N-domain but with β-barrel assembly machine protein BamA mainly via its satellite P2 domain, and that the nascent β-barrel OMPs interact with SurA via their N- and C-terminal regions. Additionally, via dual in vivo photo-crosslinking, we demonstrated the formation of a ternary complex involving β-barrel OMP, SurA, and BamA in cells. More importantly, we found that a supercomplex spanning the inner and outer membranes and involving the BamA, BamB, SurA, PpiD, SecY, SecE, and SecA proteins appears to exist in living cells, as revealed by a combined analyses of sucrose-gradient ultra-centrifugation, Blue native PAGE and mass spectrometry. We propose that this supercomplex integrates the translocation, transportation, and membrane insertion events for β-barrel OMP biogenesis. © 2016 by The American Society for Biochemistry and Molecular Biology, Inc.
Wang, Yan; Wang, Rui; Jin, Feng; Liu, Yang; Yu, Jiayu; Fu, Xinmiao; Chang, Zengyi
2016-01-01
β-barrel outer membrane proteins (OMPs) are ubiquitously present in Gram-negative bacteria, mitochondria and chloroplasts, and function in a variety of biological processes. The mechanism by which the hydrophobic nascent β-barrel OMPs are transported through the hydrophilic periplasmic space in bacterial cells remains elusive. Here, mainly via unnatural amino acid-mediated in vivo photo-crosslinking studies, we revealed that the primary periplasmic chaperone SurA interacts with nascent β-barrel OMPs largely via its N-domain but with β-barrel assembly machine protein BamA mainly via its satellite P2 domain, and that the nascent β-barrel OMPs interact with SurA via their N- and C-terminal regions. Additionally, via dual in vivo photo-crosslinking, we demonstrated the formation of a ternary complex involving β-barrel OMP, SurA, and BamA in cells. More importantly, we found that a supercomplex spanning the inner and outer membranes and involving the BamA, BamB, SurA, PpiD, SecY, SecE, and SecA proteins appears to exist in living cells, as revealed by a combined analyses of sucrose-gradient ultra-centrifugation, Blue native PAGE and mass spectrometry. We propose that this supercomplex integrates the translocation, transportation, and membrane insertion events for β-barrel OMP biogenesis. PMID:27298319
Neural effects of muscle stretching on the spinal reflexes in multiple lower-limb muscles.
Masugi, Yohei; Obata, Hiroki; Inoue, Daisuke; Kawashima, Noritaka; Nakazawa, Kimitaka
2017-01-01
While previous studies have shown that muscle stretching suppresses monosynaptic spinal reflex excitability in stretched muscles, its effects on non-stretched muscles is still largely unknown. The purpose of this study was to examine the effects of muscle stretching on monosynaptic spinal reflex in non-stretched muscles. Ten healthy male subjects participated in this study. Muscle stretching of the right triceps surae muscle was performed using a motor torque device for 1 minute. Three different dorsiflexion torques (at approximately 5, 10, and 15 Nm) were applied during muscle stretching. Spinal reflexes evoked by transcutaneous spinal cord stimulation were recorded in both the lower-limb muscles before, during, and at 0 and 5 min following muscle stretching. The amplitudes of the spinal reflexes in both the stretched and non-stretched muscles in the right (ipsilateral) leg were smaller during stretching compared to before, and at 0 and 5 min after stretching. Furthermore, the degree of reduction in the amplitude of the spinal reflexes in the right (ipsilateral) leg muscles increased significantly as the dorsiflexion torque (i.e., stretching of the right triceps surae muscles) increased. In contrast, reduction in the amplitude of the spinal reflexes with increasing dorsiflexion torque was not seen in the left (contralateral) leg muscles. Our results clearly indicate that muscle stretching has inhibitory effects on monosynaptic spinal reflexes, not only in stretched muscles, but also in non-stretched muscles of the ipsilateral leg.
Neural effects of muscle stretching on the spinal reflexes in multiple lower-limb muscles
Obata, Hiroki; Inoue, Daisuke; Kawashima, Noritaka; Nakazawa, Kimitaka
2017-01-01
While previous studies have shown that muscle stretching suppresses monosynaptic spinal reflex excitability in stretched muscles, its effects on non-stretched muscles is still largely unknown. The purpose of this study was to examine the effects of muscle stretching on monosynaptic spinal reflex in non-stretched muscles. Ten healthy male subjects participated in this study. Muscle stretching of the right triceps surae muscle was performed using a motor torque device for 1 minute. Three different dorsiflexion torques (at approximately 5, 10, and 15 Nm) were applied during muscle stretching. Spinal reflexes evoked by transcutaneous spinal cord stimulation were recorded in both the lower-limb muscles before, during, and at 0 and 5 min following muscle stretching. The amplitudes of the spinal reflexes in both the stretched and non-stretched muscles in the right (ipsilateral) leg were smaller during stretching compared to before, and at 0 and 5 min after stretching. Furthermore, the degree of reduction in the amplitude of the spinal reflexes in the right (ipsilateral) leg muscles increased significantly as the dorsiflexion torque (i.e., stretching of the right triceps surae muscles) increased. In contrast, reduction in the amplitude of the spinal reflexes with increasing dorsiflexion torque was not seen in the left (contralateral) leg muscles. Our results clearly indicate that muscle stretching has inhibitory effects on monosynaptic spinal reflexes, not only in stretched muscles, but also in non-stretched muscles of the ipsilateral leg. PMID:28662201
Svensson, Kjell; Alricsson, Marie; Karnebäck, Gustav; Magounakis, Theo; Werner, Suzanne
2016-07-01
The aim of this study was to make a comparison between players in two age groups in an elite male soccer team regarding injury localisation within the muscle-tendon unit, injury size and muscle group in terms of muscle injuries of the lower extremity. Cohort study based on data collected from a Swedish elite male soccer team during the seasons 2007-2012. In total, 145 muscle injuries were included. Injury localisation to the tendon or muscle, the size of haematoma and the affected muscle group were assessed using ultrasound. Age comparison was made between younger players (≤23 years) and older players (>23 years). No difference regarding injury localisation to either the tendon or the muscle, or the size of haematoma between the two age groups was found. However, the older group of players suffered a significantly higher number of injuries to the triceps surae than the younger players (p = 0.012). In a Swedish team of male soccer players at elite level, there was no difference between players 23 years or younger and players older than 23 years, in terms of injury distribution to muscles or tendons. Players older than 23 years sustained more injuries to triceps surae when compared with players 23 years or younger. The clinical relevance is to pay attention to muscle function of triceps surae in older players and to screen those players who may need an injury prevention programme. II.
NASA Astrophysics Data System (ADS)
Paolo Citton; Romano, Marco; Salvador, Isabella; Avanzini, Marco
2017-08-01
About thirty human footprints made approximately 12,000 years B.P. inside the 'Sala dei Misteri' Cave of Básura near Toirano, Liguria, northern Italy, were studied by standard ichnological analysis. Eleven of the best-preserved tracks were examined further using morpho-classificatory and morphometric approaches, in order to estimate the minimum number of trackmakers; biometric measurements were also used to tentatively determine their physical characteristics (e.g., height and age). Results indicate at least three different producers, two youths and the third of tender age. Analysis of the data demonstrate the power of 3D, of landmark-based morphometrics, and the utility of methods of forensic anthropology in the determination of human footprints. The study of the number of trackmakers using the principal component analysis (PCA) on 'multi-trampling' surfaces could represent a model in the ichnological study of cave sites.
NASA Astrophysics Data System (ADS)
Shindin, A. V.; Klimenko, V. V.; Kogogin, D. A.; Beletsky, A. B.; Grach, S. M.; Nasyrov, I. A.; Sergeev, E. N.
2018-05-01
We describe the method and the results of modeling and retrieval of the spatial distribution of excited oxygen atoms in the HF-pumped ionospheric region based on two-station records of artificial airglow in the red line (λ = 630 nm). The HF ionospheric pumping was provided by the Sura facility. The red-line records of the night-sky portraits were obtained at two reception points—directly at the heating facility and 170 km east of it. The results were compared with the vertical ionospheric sounding data. It was found that in the course of the experiments the airglow region was about 250 km high and did not depend on the altitude of the pump-wave resonance. The characteristic size of the region was 35 km, and the shape of the distribution isosurfaces was well described by oblique spheroids or a drop-shaped form. The average value of the maximum concentration of excited atoms during the experiment was about 1000 cm-3.
Frigon, Alain; Thibaudier, Yann; Johnson, Michael D.; Heckman, C.J.; Hurteau, Marie-France
2012-01-01
Spasticity is a condition that can include increased muscle tone, clonus, spasms, and hyperreflexia. In this study, we report the effect of manually stimulating the dorsal lumbosacral skin on spontaneous locomotor-like activity and on a variety of reflex responses in 5 decerebrate chronic spinal cats treated with clonidine. Cats were spinalized 1 month before the terminal experiment. Stretch reflexes were evoked by stretching the left triceps surae muscles. Crossed reflexes were elicited by electrically stimulating the right tibial or superficial peroneal nerves. Windup of reflex responses was evoked by electrically stimulating the left tibial or superficial peroneal nerves. We found that pinching the skin of the back abolished spontaneous locomotor-like activity. We also found that back pinch abolished the rhythmic activity observed during reflex testing without eliminating the reflex responses. Some of the rhythmic episodes of activity observed during reflex testing were consistent with clonus with an oscillation frequency greater than 3 Hz. Pinching the skin of the back effectively abolished rhythmic activity occurring spontaneously or evoked during reflex testing, irrespective of oscillation frequency. The results are consistent with the hypothesis that locomotion and clonus are produced by common central pattern-generators. Stimulating the skin of the back could prove helpful in managing undesired rhythmic activity in spinal cord-injured humans. PMID:22487200
Influence of low-level laser therapy on vertical jump in sedentary individuals
Kakihata, Camila Mayumi Martin; Malanotte, Jéssica Aline; Higa, Jessica Yumie; Errero, Tatiane Kamada; Balbo, Sandra Lucinei; Bertolini, Gladson Ricardo Flor
2015-01-01
Objective To investigate the effects of low intensity laser (660nm), on the surae triceps muscle fatigue and power, during vertical jump in sedentary individuals, in addition to delayed onset muscle soreness. Methods We included 22 sedentary volunteers in the study, who were divided into three groups: G1 (n=8) without performing low intensity laser (control); G2 (n=7) subjected to 6 days of low intensity laser applications; and G3 (n=7) subjected to 10 days of low intensity laser applications. All subjects were evaluated by means of six evaluations of vertical jumps lasting 60 seconds each. In G2 and G3, laser applications in eight points, uniformly distributed directly to the skin in the region of the triceps surae were performed. Another variable analyzed was the delayed onset muscle soreness using the Visual Analog Scale of Pain. Results There was no significant difference in fatigue and mechanical power. In the evaluation of delayed onset muscle soreness, there was significant difference, being the first evaluation higher than the others. Conclusion The low intensity laser on the triceps surae, in sedentary individuals, had no significant effects on the variables evaluated. PMID:25993067
Danner, Simon M.; Krenn, Matthias; Hofstoetter, Ursula S.; Toth, Andrea; Mayr, Winfried; Minassian, Karen
2016-01-01
Transcutaneous stimulation of the human lumbosacral spinal cord is used to evoke spinal reflexes and to neuromodulate altered sensorimotor function following spinal cord injury. Both applications require the reliable stimulation of afferent posterior root fibers. Yet under certain circumstances, efferent anterior root fibers can be co-activated. We hypothesized that body position influences the preferential stimulation of sensory or motor fibers. Stimulus-triggered responses to transcutaneous spinal cord stimulation were recorded using surface-electromyography from quadriceps, hamstrings, tibialis anterior, and triceps surae muscles in 10 individuals with intact nervous systems in the supine, standing and prone positions. Single and paired (30-ms inter-stimulus intervals) biphasic stimulation pulses were applied through surface electrodes placed on the skin between the T11 and T12 inter-spinous processes referenced to electrodes on the abdomen. The paired stimulation was applied to evaluate the origin of the evoked electromyographic response; trans-synaptic responses would be suppressed whereas direct efferent responses would almost retain their amplitude. We found that responses to the second stimulus were decreased to 14%±5% of the amplitude of the response to the initial pulse in the supine position across muscles, to 30%±5% in the standing, and to only 80%±5% in the prone position. Response thresholds were lowest during standing and highest in the prone position and response amplitudes were largest in the supine and smallest in the prone position. The responses obtained in the supine and standing positions likely resulted from selective stimulation of sensory fibers while concomitant motor-fiber stimulation occurred in the prone position. We assume that changes of root-fiber paths within the generated electric field when in the prone position increase the stimulation thresholds of posterior above those of anterior root fibers. Thus, we recommend conducting spinal reflex or neuromodulation studies with subjects lying supine or in an upright position, as in standing or stepping. PMID:26797502
Artificial Ionospheric Turbulence and Radio Wave Propagation (Sura - HAARP)
2006-11-01
investigations of AIT features, which have allowed to establish dependences of low-frequency AIT properties on PW power, frequency, and polarization , on...that a powerful HF heater wave of ordinary polarization , injected vertically from the ground into the ionosphere F-region, gives rise to secondary...or in direct proportion to the value of striation k- vector ). Basing on experimental data considered above we can conclude that for both narrow
Electrically evoked local muscle contractions cause an increase in hippocampal BDNF.
Maekawa, Takahiro; Ogasawara, Riki; Tsutaki, Arata; Lee, Kihyuk; Nakada, Satoshi; Nakazato, Koichi; Ishii, Naokata
2018-05-01
High-intensity exercise has recently been shown to cause an increase in brain-derived neurotropic factor (BDNF) in the hippocampus. Some studies have suggested that myokines secreted from contracting skeletal muscle, such as irisin (one of the truncated form of fibronectin type III domain-containing protein 5 (FNDC5)), play important roles in this process. Thus, we hypothesized that locally evoked muscle contractions may cause an increase of BDNF in the hippocampus through some afferent mechanisms. Under anesthesia, Sprague-Dawley rats were fixed on a custom-made dynamometer and their triceps surae muscles were made to maximally contract via delivery of electric stimulations of the sciatic nerve (100 Hz with 1-ms pulse and 3-s duration). Following 50 repeated maximal isometric contractions, the protein expressions of BDNF and activation of its receptor in the hippocampus significantly increased compared with the sham-operated control rats. However, the expression of both BDNF and FNDC5 within stimulated muscles did not significantly increase, nor did their serum concentrations change. These results indicate that local muscular contractions under unconsciousness can induce BDNF expression in the hippocampus. This effect may be mediated by peripheral reception of muscle contraction, but not by systemic factors.
Selective recruitment of the triceps surae muscles with changes in knee angle.
Signorile, Joseph F; Applegate, Brooks; Duque, Maurice; Cole, Natalie; Zink, Attila
2002-08-01
The muscles of the triceps surae group are important for performance in most sports and in the performance of activities of daily life. In addition, hypertrophy and balance among these muscles are integral to success in bodybuilding. The purpose of this study was to compare the muscle utilization patterns of the 2 major muscles of the triceps surae group, the soleus (SOL) and gastrocnemius (lateral head = LG and medial head = MG), and the tibialis anterior (TA) as an antagonist muscle to the group. Their electromyographic (EMG) signals were compared during 50 constant external resistance contractions at a level established before the testing session. Eleven experienced subjects contributed data during plantar flexion at 3 different knee angles (90, 135, and 180 degrees ). Both root mean square amplitude and integrated signal analyses of the EMGs revealed that the MG produced significantly greater activity than either the SOL or TA at 180 degrees, whereas the LG was not different from the SOL at any knee angle measured. Data also revealed that the SOL produced less electrical activity at 180 degrees than at the other knee angles, whereas the MG produced greater electrical activity. As would be expected, the TA produced lower EMG values than any of the triceps surae muscles at all angles tested. These data indicate that selective targeting of the SOL and MG is possible through the manipulation of knee angle. This targeting appears to be controlled by the biarticular and monoarticular structures of the MG and SOL, respectively. The LG appears less affected by knee position than the MG. Results suggest that the SOL can be targeted most effectively with the knee flexed at 90 degrees and the MG with the leg fully extended. The LG appears to also be more active at 180 degrees; however, it is not as affected as the MG or SOL by knee angle.
Vaghefi, Mahsa; Nasrabadi, Ali Motie; Golpayegani, Seyed Mohammad Reza Hashemi; Mohammadi, Mohammad-Reza; Gharibzadeh, Shahriar
2015-02-01
The aim of this study is to investigate the effect of Quran on a Persian-speaking Muslim. Volunteers listened to three different audio files (Verses from Sura 'Forqan' unconsciously; Arabic text unconsciously; Verses from Sura 'Fath' consciously). EEG signals were recorded and the changes in the relative power of theta and alpha band are considered an indicators of relaxation. The findings indicate that conscious listening to Holy Quran increases the relative theta power in most areas of the head, compared to the rest condition, and listening to Quran unconsciously increased relative theta power in the frontal and central lobes of the head significantly, compared to the rest condition. Also, listening to Quran consciously increases the relative alpha power in the frontal lobe, compared to the rest condition.
De Monte, Gianpiero; Arampatzis, Adamantios
2008-07-19
The purpose of this study was to examine the influence of different shortening velocities preceding the stretch on moment generation of the triceps surae muscles and architecture of the m. gastrocnemius medialis after shortening-stretch cycles of equal magnitude in vivo. Eleven male subjects (31.6+/-5.8 years, 178.4+/-7.3cm, 80.6+/-9.6kg) performed a series of electro-stimulated (85Hz) shortening-stretch plantar flexion contractions. The shortening-stretch cycles were performed at three constant angular velocities (25, 50, 100 degrees /s) in the plantar flexion direction (shortening) and at 50 degrees /s in the dorsiflexion direction (stretching). The resultant ankle joint moments were calculated through inverse dynamics. Pennation angle and fascicle length of the m. gastrocnemius medialis at rest and during contractions were measured using ultrasonography. The corresponding ankle moments, kinematics and changes in muscle architecture were analysed at seven time intervals. An analysis of variance for repeated measurements and post hoc test with Bonferroni correction was used to check the velocity-related effects on moment enhancement (alpha=0.05). The results show an increase in pennation angles and a decrease in fascicle lengths after the shortening-stretch cycle. The ankle joint moment ratio (post to pre) was higher (p<0.01) than 1.0 indicating a moment enhancement after the shortening-stretch cycle. The found ankle joint moment enhancement was 2-5% after the shortening-stretch cycle and was independed of the shortening velocity. Furthermore, the decrease in fascicle length after the shortening-stretch cycle indicates that the moment enhancement found in the present study is underestimated at least by 1-3%. Considering that the experiments have been done at the ascending limb of the force-length curve and that force enhancement is higher at the descending and the plateau region of the force-length curve, we conclude that the moment enhancement after shortening-stretch cycle can have important physiological affects while locomotion.
Artificial periodic irregularities in the high-latitude ionosphere excited by the HAARP facility
NASA Astrophysics Data System (ADS)
Bakhmetieva, N. V.; Grach, S. M.; Sergeev, E. N.; Shindin, A. V.; Milikh, G. M.; Siefring, C. L.; Bernhardt, P. A.; McCarrick, M.
2016-07-01
We present results of the new observations of artificial periodic irregularities (APIs) in the ionosphere using the High Frequency Active Auroral Research Program (HAARP) heating facility carried out in late May and early June 2014.The objective of this work is to detect API using high-latitude facility and analyze possible differences of the temporal and spatial variations of the API echoes in the high (HAARP) and middle (Sura) latitudes. Irregularities were created by the powerful wave of X mode and were sounded using the short probing pulses signals of X mode. API echoes were observed in the D, E, and F regions of the ionosphere. Amplitudes and characteristic times of the API echoes were measured. The API growth and decay times at HAARP (high latitudes) observed were similar to those at the Sura heating facility (midlatitudes).
Emotion and style in an English translation of the Quran.
Whissell, Cynthia
2004-04-01
An English translation of the Quran was studied in terms of word use patterns, emotionality of words, and style. Variables were assessed with the help of computer programs and the Dictionary of Affect in Language. On the basis of words used at unusually high frequencies, the translation of the Quran was seen to be emphatically about Allah, his Prophets and Message, and believers. The translation of the Quran was slightly less Pleasant and Active in emotional tone than everyday English and also less concrete. It contained an unusual number of negatives and was repetitive but did not contain many rare or long words. Significant differences were noted between chronologically Early and Late suras (chapters) in terms of emotion, style, and word use. An inflection point was identified in the time-line partway through the Meccan suras of the Quran.
Secreted Wnt Signaling Inhibitors in Disuse-Induced Bone Loss
2014-07-01
goal, we proposed to in‐ duce disuse (using Botox‐induced paralysis of the quadriceps, hamstrings , and soleus) in one hindlimb of a se‐ ries of mice...muscle paralysis of the lower limb via botulinum toxin (Botox; 20 U/kg) injec on into the quadriceps, hamstrings , triceps surae, and leg extensor...kg) injec on into the quadriceps, hamstrings , tri‐ ceps surae, and leg extensor compartment of the right lower limb. The le lower limb was
Influence of stretch-shortening cycle on mechanical behaviour of triceps surae during hopping.
Belli, A; Bosco, C
1992-04-01
Six subjects performed a first series of vertical plantar flexions and a second series of vertical rebounds, both involving muscle triceps surae exclusively. Vertical displacements, vertical forces and ankle angles were recorded during the entire work period of 60 seconds per series. In addition, expired gases were collected during the test and recovery for determination of the energy expenditure. Triceps surae was mechanically modelled with a contractile component and with an elastic component. Mechanical behaviour and work of the different muscle components were determined in both series. The net muscular efficiency calculated from the work performed by the centre of gravity was 17.5 +/- 3.0% (mean +/- SD) in plantar flexions and 29.9 +/- 4.8% in vertical rebounds. The net muscle efficiency calculated from the work performed by the contractile component was 17.4 +/- 2.9% in plantar flexions and 16.1 +/- 1.4% in vertical rebounds. These results suggest that the muscular efficiency differences do not reflect muscle contractile component efficiency but essentially the storage and recoil of elastic energy. This is supported by the relationship (P less than 0.01) found in vertical rebounds between the extra work and the elastic component work. A detailed observation of the mechanical behaviour of muscle mechanical components showed that the strategy to maximize the elastic work depends also on the force-velocity characteristics of the movement and that the eccentric-concentric work of the contractile component does not always correspond respectively to the ankle extension-flexion.
The Influence of a Bout of Exertion on Novice Barefoot Running Dynamics
Hashish, Rami; Samarawickrame, Sachithra D.; Baker, Lucinda; Salem, George J.
2016-01-01
Barefoot, forefoot strike (FFS) running has recently risen in popularity. Relative to shod, rear-foot strike (RFS) running, employing a FFS is associated with heightened triceps surae muscle activation and ankle mechanical demand. Novice to this pattern, it is plausible that habitually shod RFS runners exhibit fatigue to the triceps surae when acutely transitioning to barefoot running, thereby limiting their ability to attenuate impact. Therefore, the purpose was to determine how habitually shod RFS runners respond to an exertion bout of barefoot running, operationally defined as a barefoot run 20% of mean daily running distance. Twenty-one RFS runners performed novice barefoot running, before and after exertion. Ankle peak torque, triceps surae EMG median frequency, foot-strike patterns, joint energy absorption, and loading rates were evaluated. Of the 21 runners, 6 maintained a RFS, 10 adopted a mid-foot strike (MFS), and 5 adopted a FFS during novice barefoot running. In-response to exertion, MFS and FFS runners demonstrated reductions in peak torque, median frequency, and ankle energy absorption, and an increase in loading rate. RFS runners demonstrated reductions in peak torque and loading rate. These results indicate that a short bout of running may elicit fatigue to novice barefoot runners, limiting their ability to attenuate impact. Key points In response to exertion, novice barefoot runners demonstrate fatigue to their soleus. In response to exertion, novice barefoot runners demonstrate a reduction in ankle energy absorption In response to exertion, novice barefoot runners demonstrate an increase in loading rate PMID:27274672
The Influence of a Bout of Exertion on Novice Barefoot Running Dynamics.
Hashish, Rami; Samarawickrame, Sachithra D; Baker, Lucinda; Salem, George J
2016-06-01
Barefoot, forefoot strike (FFS) running has recently risen in popularity. Relative to shod, rear-foot strike (RFS) running, employing a FFS is associated with heightened triceps surae muscle activation and ankle mechanical demand. Novice to this pattern, it is plausible that habitually shod RFS runners exhibit fatigue to the triceps surae when acutely transitioning to barefoot running, thereby limiting their ability to attenuate impact. Therefore, the purpose was to determine how habitually shod RFS runners respond to an exertion bout of barefoot running, operationally defined as a barefoot run 20% of mean daily running distance. Twenty-one RFS runners performed novice barefoot running, before and after exertion. Ankle peak torque, triceps surae EMG median frequency, foot-strike patterns, joint energy absorption, and loading rates were evaluated. Of the 21 runners, 6 maintained a RFS, 10 adopted a mid-foot strike (MFS), and 5 adopted a FFS during novice barefoot running. In-response to exertion, MFS and FFS runners demonstrated reductions in peak torque, median frequency, and ankle energy absorption, and an increase in loading rate. RFS runners demonstrated reductions in peak torque and loading rate. These results indicate that a short bout of running may elicit fatigue to novice barefoot runners, limiting their ability to attenuate impact. Key pointsIn response to exertion, novice barefoot runners demonstrate fatigue to their soleus.In response to exertion, novice barefoot runners demonstrate a reduction in ankle energy absorptionIn response to exertion, novice barefoot runners demonstrate an increase in loading rate.
Metabolic responses to the seated calf press exercise performed against inertial resistance.
Caruso, John F; Herron, Jacquelyn C; Hernandez, Daniel A; Porter, Aaron; Schweickert, Torrey; Manning, Tommy F
2005-11-01
Future in-flight strength training devices may use inertial resistance to abate mass and strength losses to muscle groups such as the triceps surae, which incurs pronounced deficits from space travel. Yet little data exist regarding physiological outcomes to triceps surae exercise performed against inertial resistance. Two sets of subjects were employed to note either blood lactate (La-) or net caloric cost responses to seated calf presses done on an inertial resistance ergometer. Both sets of subjects performed 3 identical 3-set 10-repetition workouts. Blood La- measurements were made pre- and 5 min post-exercise. During workouts, breath-by-breath O2 uptake values were also recorded to help determine the net caloric cost of exercise. Compared to pre-exercise (mean +/- SEM) blood La- (2.01 +/- 0.08 mmol x L(-1)) values, post-exercise (4.73 +/- 0.24 mmol x L(-1)) measurements showed a significant increase. Delta (post/pre differences) La- correlated significantly (r = 0.31-0.34) to several workout performance measures. Net caloric cost averaged 52.82 +/- 3.26 kcals for workouts; multivariate regression showed a subject's height, body mass, and body surface area described the variance associated with energy expenditure. Workouts evoked minimal energy expenditure, though anaerobic glycolysis likely played a major role in ATP resynthesis. Metabolic and exercise performance measures were likely influenced by series elastic element involvement of the triceps surae-Achilles tendon complex. Ergometer calf presses provided a high-intensity workout stimulus with a minimal metabolic cost.
The Functional Role of the Triceps Surae Muscle during Human Locomotion
Honeine, Jean-Louis; Schieppati, Marco; Gagey, Olivier; Do, Manh-Cuong
2013-01-01
Aim Despite numerous studies addressing the issue, it remains unclear whether the triceps surae muscle group generates forward propulsive force during gait, commonly identified as ‘push-off’. In order to challenge the push-off postulate, one must probe the effect of varying the propulsive force while annulling the effect of the progression velocity. This can be obtained by adding a load to the subject while maintaining the same progression velocity. Methods Ten healthy subjects initiated gait in both unloaded and loaded conditions (about 30% of body weight attached at abdominal level), for two walking velocities, spontaneous and fast. Ground reaction force and EMG activity of soleus and gastrocnemius medialis and lateralis muscles of the stance leg were recorded. Centre of mass velocity and position, centre of pressure position, and disequilibrium torque were calculated. Results At spontaneous velocity, adding the load increased disequilibrium torque and propulsive force. However, load had no effect on the vertical braking force or amplitude of triceps activity. At fast progression velocity, disequilibrium torque, vertical braking force and triceps EMG increased with respect to spontaneous velocity. Still, adding the load did not further increase braking force or EMG. Conclusions Triceps surae is not responsible for the generation of propulsive force but is merely supporting the body during walking and restraining it from falling. By controlling the disequilibrium torque, however, triceps can affect the propulsive force through the exchange of potential into kinetic energy. PMID:23341916
Robertson, Benjamin D; Sawicki, Gregory S
2014-07-21
We present a simplified Hill-type model of the human triceps surae-Achilles tendon complex working on a gravitational-inertial load during cyclic contractions (i.e. vertical hopping). Our goal was to determine the role that neural control plays in governing muscle, or contractile element (CE), and tendon, or series elastic element (SEE), mechanics and energetics within a compliant muscle-tendon unit (MTU). We constructed a 2D parameter space consisting of many combinations of stimulation frequency and magnitude (i.e. neural control strategies). We compared the performance of each control strategy by evaluating peak force and average positive mechanical power output for the system (MTU) and its respective components (CE, SEE), force-length (F-L) and -velocity (F-V) operating point of the CE during active force production, average metabolic rate for the CE, and both MTU and CE apparent efficiency. Our results suggest that frequency of stimulation plays a primary role in governing whole-MTU mechanics. These include the phasing of both activation and peak force relative to minimum MTU length, average positive power, and apparent efficiency. Stimulation amplitude was primarily responsible for governing average metabolic rate and within MTU mechanics, including peak force generation and elastic energy storage and return in the SEE. Frequency and amplitude of stimulation both played integral roles in determining CE F-L operating point, with both higher frequency and amplitude generally corresponding to lower CE strains, reduced injury risk, and elimination of the need for passive force generation in the CE parallel elastic element (PEE). Copyright © 2014 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Frolov, V. L.; Rapoport, V. O.; Schorokhova, E. A.; Belov, A. S.; Parrot, M.; Rauch, J.-L.
2016-08-01
In this paper we systematize the results of studying the characteristics of the plasma-density ducts, which was conducted in 2005-2010 during the DEMETER-satellite operation. The ducts are formed at altitudes of about 700 km as a result of the ionospheric F 2 region modification by high-power high-frequency radio waves radiated by the midlatitude SURA heating facility. All the performed measurements are used as the basis for determining the formation conditions for such ducts, the duct characteristics are studied, and the opportunities for the duct influence on the ionosphere-magnetosphere coupling and propagation of radio waves of various frequency ranges are demonstrated. The results of numerical simulation of the formation of such ducts are presented.
Output of skeletal muscle contractions. a study of isokinetic plantar flexion in athletes.
Fugl-Meyer, A R; Mild, K H; Hörnsten, J
1982-06-01
Maximum torques, total work and mean power of isokinetic plantar flexions were measured with simultaneous registrations. The integrated electromyograms (iEMG) were obtained by surface electrodes from all three heads of the m. triceps surae. The method applied offers possibilities for adequate description of dynamic muscular work which in the case of plantar flexion in trained man declines as a negative exponential function of angular motion velocity. The decline is parallel to that of maximum torques. The summed triceps surae iEMG was inversely proportional to the velocity and direct proportional to time suggesting that structural rather than neural factors determine the relationships between velocity of angular motion and maximum torque/total work of single Mmaneuvers. Moreover, the fact that maximum mean power as well as maximum electrical efficiency were reached at the functional velocity of toe-off during gait suggests an influence of pragmatic demands on plantar flexion mechanical output.
Plyometric Training Favors Optimizing Muscle–Tendon Behavior during Depth Jumping
Hirayama, Kuniaki; Iwanuma, Soichiro; Ikeda, Naoki; Yoshikawa, Ayumi; Ema, Ryoichi; Kawakami, Yasuo
2017-01-01
The purpose of the present study was to elucidate how plyometric training improves stretch–shortening cycle (SSC) exercise performance in terms of muscle strength, tendon stiffness, and muscle–tendon behavior during SSC exercise. Eleven men were assigned to a training group and ten to a control group. Subjects in the training group performed depth jumps (DJ) using only the ankle joint for 12 weeks. Before and after the period, we observed reaction forces at foot, muscle–tendon behavior of the gastrocnemius, and electromyographic activities of the triceps surae and tibialis anterior during DJ. Maximal static plantar flexion strength and Achilles tendon stiffness were also determined. In the training group, maximal strength remained unchanged while tendon stiffness increased. The force impulse of DJ increased, with a shorter contact time and larger reaction force over the latter half of braking and initial half of propulsion phases. In the latter half of braking phase, the average electromyographic activity (mEMG) increased in the triceps surae and decreased in tibialis anterior, while fascicle behavior of the gastrocnemius remained unchanged. In the initial half of propulsion, mEMG of triceps surae and shortening velocity of gastrocnemius fascicle decreased, while shortening velocity of the tendon increased. These results suggest that the following mechanisms play an important role in improving SSC exercise performance through plyometric training: (1) optimization of muscle–tendon behavior of the agonists, associated with alteration in the neuromuscular activity during SSC exercise and increase in tendon stiffness and (2) decrease in the neuromuscular activity of antagonists during a counter movement. PMID:28179885
Franz, Jason R.; Thelen, Darryl G.
2016-01-01
The Achilles tendon (AT) is a complex structure, consisting of distinct fascicle bundles arising from each triceps surae muscle that may act as mechanically independent structures. Advances in tissue imaging are rapidly accelerating our understanding of the complexities of functional Achilles tendon behavior, with potentially important implications for musculoskeletal injury and performance. In this overview of our recent contributions to these efforts, we present the results of complementary experimental and computational approaches to investigate AT behavior during walking and its potential relevance to reduced triceps surae mechanical performance due to aging. Our experimental evidence reveals that older tendons exhibit smaller differences in tissue deformations than young adults between regions of the AT presumed to arise from the gastrocnemius and soleus muscles. These observations are consistent with a reduced capacity for inter-fascicle sliding within the AT, which could have implications for the mechanical independence of the triceps surae muscles. More uniform AT deformations are also correlated with hallmark biomechanical features of elderly gait – namely, a loss of net ankle moment, power, and positive work during push-off. Simulating age-related reductions in the capacity for inter-fascicle sliding in the AT during walking predicts detriments in gastrocnemius muscle-tendon mechanical performance coupled with underlying shifts in fascicle kinematics during push-off. AT compliance, also suspected to vary due to age, systematically modulates those effects. By integrating in vivo imaging with computational modeling, we have gained theoretical insight into multi-scale biomechanical changes due to aging, hypotheses regarding their functional effects, and opportunities for experiments that validate or invalidate these assertions. PMID:27209552
Matsukawa, Kanji; Ishii, Kei; Kadowaki, Akito; Liang, Nan; Ishida, Tomoko
2012-08-15
Our laboratory has reported that central command blunts the sensitivity of the aortic baroreceptor-heart rate (HR) reflex at the onset of voluntary static exercise in conscious cats and spontaneous contraction in decerebrate cats. The purpose of this study was to examine whether central command attenuates the sensitivity of the carotid sinus baroreceptor-HR reflex at the onset of spontaneous, fictive motor activity in paralyzed, decerebrate cats. We confirmed that aortic nerve (AN)-stimulation-induced bradycardia was markedly blunted to 26 ± 4.4% of the control (21 ± 1.3 beats/min) at the onset of spontaneous motor activity. Although the baroreflex bradycardia by electrical stimulation of the carotid sinus nerve (CSN) was suppressed (P < 0.05) to 86 ± 5.6% of the control (38 ± 1.2 beats/min), the inhibitory effect of spontaneous motor activity was much weaker (P < 0.05) with CSN stimulation than with AN stimulation. The baroreflex bradycardia elicited by brief occlusion of the abdominal aorta was blunted to 36% of the control (36 ± 1.6 beats/min) during spontaneous motor activity, suggesting that central command is able to inhibit the cardiomotor sensitivity of arterial baroreflexes as the net effect. Mechanical stretch of the triceps surae muscle never affected the baroreflex bradycardia elicited by AN or CSN stimulation and by aortic occlusion, suggesting that muscle mechanoreflex did not modify the cardiomotor sensitivity of aortic and carotid sinus baroreflex. Since the inhibitory effect of central command on the carotid baroreflex pathway, associated with spontaneous motor activity, was much weaker compared with the aortic baroreflex pathway, it is concluded that central command does not force a generalized modulation on the whole pathways of arterial baroreflexes but provides selective inhibition for the cardiomotor component of the aortic baroreflex.
Immediate effect of exercise on achilles tendon properties: systematic review.
Obst, Steven J; Barrett, Rod S; Newsham-West, Richard
2013-08-01
Understanding the mechanical and morphological adaptation of the Achilles tendon (AT) in response to acute exercise could have important implications for athletic performance, injury prevention, and rehabilitation. The purpose of this study was to conduct a systematic review and critical evaluation of the literature to determine the immediate effect of a single bout of exercise on the mechanical and morphological properties of the AT in vivo. Five electronic research databases were systematically searched for intervention-based studies reporting mechanical and morphological properties of the AT after a single bout of exercise. Searches revealed 3292 possible articles; 21 met the inclusion criteria. There is evidence that maximal isometric contractions and prolonged static stretching (>5 min) of the triceps surae complex cause an immediate decrease in AT stiffness, whereas prolonged running and hopping have minimal effect. Limited but consistent evidence exists, indicating that AT hysteresis is reduced after prolonged static stretching. Consistent evidence supports a reduction in free AT diameter (anterior-posterior) after dynamic ankle exercise, and this change appears most pronounced in the healthy tendon and after eccentric exercise. The mechanical and morphological properties of the AT in vivo are affected by acute exercise in a mode- and dose-dependent manner. Transient changes in AT stiffness, hysteresis, and diameter after unaccustomed exercise modes and doses may expose the tendon to increased risk of strain injury and impact on the mechanical function of the triceps surae muscle-tendon unit.
NASA Astrophysics Data System (ADS)
Kerr, P. C.; Donahue, A.; Westerink, J. J.; Luettich, R.; Zheng, L.; Weisberg, R. H.; Wang, H. V.; Slinn, D. N.; Davis, J. R.; Huang, Y.; Teng, Y.; Forrest, D.; Haase, A.; Kramer, A.; Rhome, J.; Feyen, J. C.; Signell, R. P.; Hanson, J. L.; Taylor, A.; Hope, M.; Kennedy, A. B.; Smith, J. M.; Powell, M. D.; Cardone, V. J.; Cox, A. T.
2012-12-01
The Southeastern Universities Research Association (SURA), in collaboration with the NOAA Integrated Ocean Observing System program and other federal partners, developed a testbed to help accelerate progress in both research and the transition to operational use of models for both coastal and estuarine prediction. This testbed facilitates cyber-based sharing of data and tools, archival of observation data, and the development of cross-platform tools to efficiently access, visualize, skill assess, and evaluate model results. In addition, this testbed enables the modeling community to quantitatively assess the behavior (e.g., skill, robustness, execution speed) and implementation requirements (e.g. resolution, parameterization, computer capacity) that characterize the suitability and performance of selected models from both operational and fundamental science perspectives. This presentation focuses on the tropical coastal inundation component of the testbed and compares a variety of model platforms as well as grids in simulating tides, and the wave and surge environments for two extremely well documented historical hurricanes, Hurricanes Rita (2005) and Ike (2008). Model platforms included are ADCIRC, FVCOM, SELFE, SLOSH, SWAN, and WWMII. Model validation assessments were performed on simulation results using numerous station observation data in the form of decomposed harmonic constituents, water level high water marks and hydrographs of water level and wave data. In addition, execution speed, inundation extents defined by differences in wetting/drying schemes, resolution and parameterization sensitivities are also explored.
Assessment of H reflex sensitivity with M wave alternation consequent to fatiguing contractions.
Hwang, Ing-Shiou; Huang, Cheng-Ya; Wu, Pei-Shan; Chen, Yi-Ching; Wang, Chun-Hou
2008-09-01
The objective of this study was to examine the changes in H reflex sensitivity after neuromuscular fatigue associated with fluctuations of the M wave. In the maximal and submaximal voluntary contraction (MVC and SMVC) paradigms, subjects performed voluntary plantarflexion at 100% MVC and 40% MVC respectively until the limit of torque maintenance was reached. In the submaximal electrical stimulation (SMES) paradigm, the tricep surae was exhausted with sustained electrical stimulation of 40% of the maximal tolerable intensity at a 40-Hz stimulus rate. The H reflexes and maximal M waves (M(max)) of the soleus were recorded before and after the three fatigue paradigms, and the H reflex was standardized with M(max) to minimize possible bias due to fatigue-induced M wave fluctuation. The results showed a significant increase in the standardized H reflex due to the SMES paradigm in spite of M(max) potentiation. The SMVC paradigm led to a reduction in size of the standardized H reflex without modification of M(max), whereas the standardized H reflex was not mediated by the MVC paradigm, which contributed to a noticeable M(max) potentiation. The present study underscored the fact that the H reflex sensitivity and M wave amplitude were not necessarily suppressed consequent to neuromuscular fatigue, but varied with the activation history of a muscle for size-dependent efficacy of the Ia transmission pathways and postactivation potentiation.
Postural stability is altered by the stimulation of pain but not warm receptors in humans.
Blouin, Jean-Sébastien; Corbeil, Philippe; Teasdale, Normand
2003-10-17
It is now recognized that large diameter myelinated afferents provide the primary source of lower limb proprioceptive information for maintaining an upright standing position. Small diameter afferents transmitting noxious stimuli, however, can also influence motor behaviors. Despite the possible influence of pain on motor behaviors, the effects of pain on the postural control system have not been well documented. Two cutaneous heat stimulations (experiment 1: non-noxious 40 degrees C; experiment 2: noxious 45 degrees C) were applied bilaterally on the calves of the subject with two thermal grills to stimulate A delta and C warm receptors and nociceptors in order to examine their effects on postural stability. The non-noxious stimulation induced a gentle sensation of warmth and the noxious stimulation induced a perception of heat pain (visual analogue scores of 0 and 46 mm, respectively). For both experiments, ten healthy young adults were tested with and without heat stimulations of the lower limbs while standing upright on a force platform with eyes open, eyes closed and eyes closed with tendon co-vibration of tibialis anterior and triceps surae muscles. The center of pressure displacements were analyzed to examine how both stimulations affected the regulation of quiet standing and if the effects were exacerbated when vision was removed or ankle proprioception perturbed. The stimulation of the warm receptors (40 degrees C) did not induce any postural deterioration. With pain (45 degrees C), subjects showed a significant increase in standard deviation, range and mean velocity of postural oscillations as well as standard deviation of the center of pressure velocity. The effects of heat pain were exacerbated when subjects had both their eyes closed and ankle tendons vibrated (increased standard deviation of the center of pressure velocity and mean velocity of the center of pressure). A non-noxious stimulation (40 degrees C) of the small diameter afferents is not a sufficiently intense sensory stimulation to alter the control of posture. A painful stimulation (45 degrees C) of the skin thermoreceptors, however, yielded a deterioration of the postural control system. The observed deteriorating effects of the combined stimulation of nociceptors and Ia afferents (when ankle tendons were vibrated) could result from the convergence of these afferents at the spinal level. This could certainly lead to the hypothesis that individuals suffering from lower limb pain present alterations of the postural control mechanisms; especially populations already at risk of falling (for example, frail elderly) or populations suffering from concomitant lower limb pain and sensory deficits (for example, diabetic polyneuropathy).
2006-08-01
latitude ( HAARP , TROMSO) and mid latitude (SURA) facilities [1]. The very strong and fully reproducible plasma perturbations in ionosphere are observed...beam propagating along magnetic field (θ = 0), in this case factor κs ≈ 1. As an a example we will consider now the HAARP facility. The ERP for HAARP ...as a function of fre- quency f0 is presented in the Table 1. ISTC 2236p 12 Table 1 ERP as function of wave frequency for HAARP (2001) f0 (MHz
Iwanuma, Soichiro; Akagi, Ryota; Hashizume, Satoru; Kanehisa, Hiroaki; Yanai, Toshimasa; Kawakami, Yasuo
2011-09-23
The purpose of this study was to clarify how foot deformation affects the relationship between triceps surae muscle-tendon unit (MTU) length and ankle joint angle. For six women and six men a series of sagittal magnetic resonance (MR) images of the right foot were taken, and changes in MTU length (the displacement of the calcaneal tuberosity), foot arch angle, and ankle joint angle were measured. In the passive session, each subject's ankle joint was secured at 10° dorsiflexed position, neutral position (NP), and 10° and 20° plantar flexed positions while MR images were acquired. In the active session, each subject was requested to perform submaximal isometric plantar flexions (30%, 60%, and 80% of voluntary maximum) at NP. The changes in MTU length in each trial were estimated by two different formulae reported previously. The changes of the measured MTU length as a function of ankle joint angles observed in all trials of the active session were significantly (p<0.05) larger than corresponding values in the passive session and by the estimation formulae. In the passive session, MTU length changes were significantly smaller than the estimated values when the ankle was plantar flexed. The foot arch angle increased as the contraction level increased from rest (117 ± 4°) to 80% (125 ± 3°), and decreased as the ankle was positioned further into plantar flexion in the passive session (115 ± 3°). These results indicate that foot deformation profoundly affects the triceps surae MTU length-ankle joint angle relationship during plantar flexion. Copyright © 2011 Elsevier Ltd. All rights reserved.
Gladwell, V F; Coote, J H
2002-01-01
Previous evidence suggests that the heart rate (HR) increase observed with isometric exercise is dependent on different afferent mechanisms to those eliciting the increase in blood pressure (BP). Central command and muscle metaboreceptors have been shown to contribute to this differential effect. However, in experimental animals passive stretch of the hindlimb increases HR suggesting that small fibre mechanoreceptors could also have a role. This has not been previously shown in humans and was investigated in this study. Healthy human volunteers were instrumented to record BP, ECG, respiration, EMG of rectus femoris and gastrocnemius and contraction force of triceps surae. Voluntary isometric contraction of triceps surae elicited a significant HR change in the first three respiratory cycles at 40 % of maximum voluntary contraction whereas BP did not change significantly until after 30 s. This suggests that different mechanisms are involved in the initiation of the cardiovascular changes. Sustained passive stretch of triceps surae for 1 min, by dorsiflexion of the foot, caused a significant (P < 0.05) increase in HR (5 ± 2.6 beats min−1) with no significant change in BP. A time domain measure of cardiac vagal activity was reduced significantly during passive stretch from 69.7 ± 12.9 to 49.6 ± 8.9 ms. Rapid rhythmic passive stretch (0.5 Hz for 1 min) was without significant effect suggesting that large muscle proprioreceptors are not involved. We conclude that in man small fibre muscle mechanoreceptors responding to stretch, inhibit cardiac vagal activity and thus increase HR. These afferents could contribute to the initial cardiac acceleration in response to muscle contraction. PMID:11986394
Flavell, Carol A.; Sayers, Mark G. L.; Gordon, Susan J.; Lee, James B.
2013-01-01
The front row of a rugby union scrum consists of three players. The loose head prop, hooker and tight head prop. The objective of this study was to determine if known biomechanical risk factors for triceps surae muscle injury are exhibited in the lower limb of front row players during contested scrummaging. Eleven high performance front row rugby union players were landmarked bilaterally at the posterior superior iliac spine (PSIS), greater trochanter, lateral femoral epicondyle, midline of the calcaneus above the plantar aspect of the heel, midline lower leg 5cm and 20cm proximal to the lateral malleolus, at the axis of subtalar joint, lateral malleolus, and head of the fifth metatarsal. Players were video recorded during a series of 2 on 1 live scrummaging drills. Biomechanical three dimensional analysis identified large angular displacements, and increased peak velocities and accelerations at the ankle joint during attacking scrummaging drill techniques when in the stance phase of gait. This places the triceps surae as increased risk of injury and provides valuable information for training staff regarding injury prevention and scrum training practices for front row players. Key points Front rowers exhibited patterns of single leg weight bearing, in a position of greater ankle plantar flexion and knee extension at toe off during scrummaging, which is a risk position for TS injury. Front rowers also exhibited greater acceleration at the ankle, knee, and hip joints, and greater changes in ankle ROM from toe strike to toe off during attacking scrum drills. These reported accelerations and joint displacements may be risk factors for TS injury, as the ankle is accelerating into plantar flexion at final push off and the muscle is shortening from an elongated state. PMID:24149740
Franz, Jason R; Thelen, Darryl G
2016-06-14
The Achilles tendon (AT) is a complex structure, consisting of distinct fascicle bundles arising from each triceps surae muscle that may act as mechanically independent structures. Advances in tissue imaging are rapidly accelerating our understanding of the complexities of functional Achilles tendon behavior, with potentially important implications for musculoskeletal injury and performance. In this overview of our recent contributions to these efforts, we present the results of complementary experimental and computational approaches to investigate AT behavior during walking and its potential relevance to reduced triceps surae mechanical performance due to aging. Our experimental evidence reveals that older tendons exhibit smaller differences in tissue deformations than young adults between regions of the AT presumed to arise from the gastrocnemius and soleus muscles. These observations are consistent with a reduced capacity for inter-fascicle sliding within the AT, which could have implications for the mechanical independence of the triceps surae muscles. More uniform AT deformations are also correlated with hallmark biomechanical features of elderly gait - namely, a loss of net ankle moment, power, and positive work during push-off. Simulating age-related reductions in the capacity for inter-fascicle sliding in the AT during walking predicts detriments in gastrocnemius muscle-tendon mechanical performance coupled with underlying shifts in fascicle kinematics during push-off. AT compliance, also suspected to vary due to age, systematically modulates those effects. By integrating in vivo imaging with computational modeling, we have gained theoretical insight into multi-scale biomechanical changes due to aging, hypotheses regarding their functional effects, and opportunities for experiments that validate or invalidate these assertions. Copyright © 2016 Elsevier Ltd. All rights reserved.
Csapo, Robert; Malis, Vadim; Sinha, Usha
2015-01-01
The aim of this study was to assess the correlation between contraction-associated muscle kinematics as measured by velocity-encoded phase-contrast (VE-PC) magnetic resonance imaging (MRI) and activity recorded via electromyography (EMG), and to construct a detailed three-dimensional (3-D) map of the contractile behavior of the triceps surae complex from the MRI data. Ten axial-plane VE-PC MRI slices of the triceps surae and EMG data were acquired during submaximal isometric contractions in 10 subjects. MRI images were analyzed to yield the degree of contraction-associated muscle displacement on a voxel-by-voxel basis and determine the heterogeneity of muscle movement within and between slices. Correlational analyses were performed to determine the agreement between EMG data and displacements. Pearson's coefficients demonstrated good agreement (0.84 < r < 0.88) between EMG data and displacements. Comparison between different slices in the gastrocnemius muscle revealed significant heterogeneity in displacement values both in-plane and along the cranio-caudal axis, with highest values in the mid-muscle regions. By contrast, no significant differences between muscle regions were found in the soleus muscle. Substantial differences among displacements were also observed within slices, with those in static areas being only 17–39% (maximum) of those in the most mobile muscle regions. The good agreement between EMG data and displacements suggests that VE-PC MRI may be used as a noninvasive, high-resolution technique for quantifying and modeling muscle activity over the entire 3-D volume of muscle groups. Application to the triceps surae complex revealed substantial heterogeneity of contraction-associated muscle motion both within slices and between different cranio-caudal positions. PMID:26112239
Flavell, Carol A; Sayers, Mark G L; Gordon, Susan J; Lee, James B
2013-01-01
The front row of a rugby union scrum consists of three players. The loose head prop, hooker and tight head prop. The objective of this study was to determine if known biomechanical risk factors for triceps surae muscle injury are exhibited in the lower limb of front row players during contested scrummaging. Eleven high performance front row rugby union players were landmarked bilaterally at the posterior superior iliac spine (PSIS), greater trochanter, lateral femoral epicondyle, midline of the calcaneus above the plantar aspect of the heel, midline lower leg 5cm and 20cm proximal to the lateral malleolus, at the axis of subtalar joint, lateral malleolus, and head of the fifth metatarsal. Players were video recorded during a series of 2 on 1 live scrummaging drills. Biomechanical three dimensional analysis identified large angular displacements, and increased peak velocities and accelerations at the ankle joint during attacking scrummaging drill techniques when in the stance phase of gait. This places the triceps surae as increased risk of injury and provides valuable information for training staff regarding injury prevention and scrum training practices for front row players. Key pointsFront rowers exhibited patterns of single leg weight bearing, in a position of greater ankle plantar flexion and knee extension at toe off during scrummaging, which is a risk position for TS injury.Front rowers also exhibited greater acceleration at the ankle, knee, and hip joints, and greater changes in ankle ROM from toe strike to toe off during attacking scrum drills.These reported accelerations and joint displacements may be risk factors for TS injury, as the ankle is accelerating into plantar flexion at final push off and the muscle is shortening from an elongated state.
Lee, Hae-Dong; Finni, Taija; Hodgson, John A; Lai, Alex M; Edgerton, V Reggie; Sinha, Shantanu
2006-06-01
The in vivo strain properties of human skeletal muscle-tendon complexes are poorly understood, particularly following chronic periods of reduced load bearing. We studied eight healthy volunteers who underwent 4 wk of unilateral lower limb suspension (ULLS) to induce chronic unloading. Before and after the ULLS, maximum isometric ankle plantar flexion torque was determined by using a magnetic resonance (MR)-compatible dynamometry. Volumes of the triceps surae muscles and strain distribution of the soleus aponeurosis and the Achilles tendon at a constant submaximal plantar flexion (20% pre-maximal voluntary contraction) were measured by using MRI and velocity-encoded, phase-contrast MRI techniques. Following ULLS, volumes of the soleus and the medial gastrocnemius and the maximum isometric ankle plantar flexion (maximum voluntary contraction) decreased by 5.5+/-1.9, 7.5+/-2.7, and 48.1+/-6.1%, respectively. The strain of the aponeurosis along the length of the muscle before the ULLS was 0.3+/-0.3%, ranging from -1.5 to 2.7% in different locations of the aponeurosis. Following ULLS, the mean strain was -6.4+/-0.3%, ranging from -1.6 to 1.3%. The strain distribution of the midregion of the aponeurosis was significantly influenced by the ULLS, whereas the more distal component showed no consistent changes. Achilles tendon strain was not affected by the ULLS. These results raise the issue as to whether these changes in strain distribution affect the functional properties of the triceps surae and whether the probability of strain injuries within the triceps surae increases following chronic unloading in those regions of this muscle complex in which unusual strains occur.
Contractile function and motor unit firing rates of the human hamstrings.
Kirk, Eric A; Rice, Charles L
2017-01-01
Neuromuscular properties of the lower limb in health, aging, and disease are well described for major lower limb muscles comprising the quadriceps, triceps surae, and dorsiflexors, with the notable exception of the posterior thigh (hamstrings). The purpose of this study was to further characterize major muscles of the lower limb by comprehensively exploring contractile properties in relation to spinal motor neuron output expressed as motor unit firing rates (MUFRs) in the hamstrings of 11 (26.5 ± 3.8) young men. Maximal isometric voluntary contraction (MVC), voluntary activation, stimulated contractile properties including a force-frequency relationship, and MUFRs from submaximal to maximal voluntary contractile intensities were assessed in the hamstrings. Strength and MUFRs were assessed at two presumably different muscle lengths by varying the knee joint angles (90° and 160°). Knee flexion MVCs were 60-70% greater in the extended position (160°). The frequency required to elicit 50% of maximum tetanic torque was 16-17 Hz. Mean MUFRs at 25-50% MVC were 9-31% less in the biceps femoris compared with the semimembranosus-semitendinosus group. Knee joint angle (muscle length) influenced MUFRs such that mean MUFRs were greater in the shortened (90°) position at 50% and 100% MVC. Compared with previous reports, mean maximal MUFRs in the hamstrings are greater than those in the quadriceps and triceps surae and somewhat less than those in the tibialis anterior. Mean maximal MUFRs in the hamstrings are influenced by changes in knee joint angle, with lower firing rates in the biceps femoris compared with the semimembranosus-semitendinosus muscle group. We studied motor unit firing rates (MUFRs) at various voluntary contraction intensities in the hamstrings, one of the only major lower limb muscles to have MUFRs affected by muscle length changes. Within the hamstrings muscle-specific differences have greater impact on MUFRs than length changes, with the biceps femoris having reduced neural drive compared with the semimembranosus-semimembranosus. Comparing our results to other lower limb muscles, flexors have inherently higher firing rate compared with extensors. Copyright © 2017 the American Physiological Society.
Contractile function and motor unit firing rates of the human hamstrings
Kirk, Eric A.
2016-01-01
Neuromuscular properties of the lower limb in health, aging, and disease are well described for major lower limb muscles comprising the quadriceps, triceps surae, and dorsiflexors, with the notable exception of the posterior thigh (hamstrings). The purpose of this study was to further characterize major muscles of the lower limb by comprehensively exploring contractile properties in relation to spinal motor neuron output expressed as motor unit firing rates (MUFRs) in the hamstrings of 11 (26.5 ± 3.8) young men. Maximal isometric voluntary contraction (MVC), voluntary activation, stimulated contractile properties including a force-frequency relationship, and MUFRs from submaximal to maximal voluntary contractile intensities were assessed in the hamstrings. Strength and MUFRs were assessed at two presumably different muscle lengths by varying the knee joint angles (90° and 160°). Knee flexion MVCs were 60–70% greater in the extended position (160°). The frequency required to elicit 50% of maximum tetanic torque was 16–17 Hz. Mean MUFRs at 25–50% MVC were 9–31% less in the biceps femoris compared with the semimembranosus-semitendinosus group. Knee joint angle (muscle length) influenced MUFRs such that mean MUFRs were greater in the shortened (90°) position at 50% and 100% MVC. Compared with previous reports, mean maximal MUFRs in the hamstrings are greater than those in the quadriceps and triceps surae and somewhat less than those in the tibialis anterior. Mean maximal MUFRs in the hamstrings are influenced by changes in knee joint angle, with lower firing rates in the biceps femoris compared with the semimembranosus-semitendinosus muscle group. NEW & NOTEWORTHY We studied motor unit firing rates (MUFRs) at various voluntary contraction intensities in the hamstrings, one of the only major lower limb muscles to have MUFRs affected by muscle length changes. Within the hamstrings muscle-specific differences have greater impact on MUFRs than length changes, with the biceps femoris having reduced neural drive compared with the semimembranosus-semimembranosus. Comparing our results to other lower limb muscles, flexors have inherently higher firing rate compared with extensors. PMID:27784806
Estrogen attenuates the cardiovascular and ventilatory responses to central command in cats.
Hayes, Shawn G; Moya Del Pino, Nicolas B; Kaufman, Marc P
2002-04-01
Static exercise is well known to increase heart rate, arterial blood pressure, and ventilation. These increases appear to be less in women than in men, a difference that has been attributed to an effect of estrogen on neuronal function. In decerebrate male cats, we examined the effect of estrogen (17beta-estradiol; 0.001, 0.01, 0.1, and 1.0 microg/kg iv) on the cardiovascular and ventilatory responses to central command and the exercise pressor reflex, the two neural mechanisms responsible for evoking the autonomic and ventilatory responses to exercise. We found that 17beta-estradiol, in each of the three doses tested, attenuated the pressor, cardioaccelerator, and phrenic nerve responses to electrical stimulation of the mesencephalic locomotor region (i.e., central command). In contrast, none of the doses of 17beta-estradiol had any effect on the pressor, cardioaccelerator, and ventilatory responses to static contraction or stretch of the triceps surae muscles. We conclude that, in decerebrate male cats, estrogen injected intravenously attenuates cardiovascular and ventilatory responses to central command but has no effect on responses to the exercise pressor reflex.
Radio Sounding of the Magnetopause from the Ground (NIRFI Part)
2000-04-06
subsolar point sounding from SURA location leads to oblique sounding wave propagation through the ionosphere when penetration condition requires less... ecliptic plane (along the direction of solar wind sector boundaries, morning hours) • near the subsolar point (along the solar wind velocity, noon
Wu, Si; Ge, Xi; Lv, Zhixin; Zhi, Zeyong; Chang, Zengyi; Zhao, Xin Sheng
2011-09-15
The OMPs (outer membrane proteins) of Gram-negative bacteria have to be translocated through the periplasmic space before reaching their final destination. The aqueous environment of the periplasmic space and high permeability of the outer membrane engender such a translocation process inevitably challenging. In Escherichia coli, although SurA, Skp and DegP have been identified to function in translocating OMPs across the periplasm, their precise roles and their relationship remain to be elucidated. In the present paper, by using fluorescence resonance energy transfer and single-molecule detection, we have studied the interaction between the OMP OmpC and these periplasmic quality control factors. The results of the present study reveal that the binding rate of OmpC to SurA or Skp is much faster than that to DegP, which may lead to sequential interaction between OMPs and different quality control factors. Such a kinetic partitioning mechanism for the chaperone-substrate interaction may be essential for the quality control of the biogenesis of OMPs.
Effect of toe extension on EMG of triceps surae muscles during isometric dorsiflexion.
Siddiqi, Ariba; Arjunan, Sridhar P; Kumar, Dinesh
2016-12-01
The protocol for estimating force of contraction by triceps surae (TS) muscles requires the immobilization of the ankle during dorsiflexion and plantar flexion. However, large variability in the results has been observed. To identify the cause of this variability, experiments were conducted where ankle dorsiflexion force and electromyogram (EMG) of the TS were recorded under two conditions: (i) toes were strapped and (ii) toes were unstrapped, with all other conditions such as immobilization of the ankle remaining unchanged. The root mean square (RMS) of the EMG and the force were analyzed and one-tail Student's t-test was performed for significance between the two conditions. The RMS of the EMG from TS muscles was found to be significantly higher (~55%) during dorsiflexion with toes unstrapped compared with when the toes were strapped. The torque corresponding to dorsiflexion was also higher with toes unstrapped. Our study has shown that it is important to strap the toes when measuring the torque at the ankle and EMG of the TS muscles.
By counteracting gravity, triceps surae sets both kinematics and kinetics of gait
Honeine, Jean‐Louis; Schieppati, Marco; Gagey, Oliver; Do, Manh‐Cuong
2014-01-01
Abstract In the single‐stance phase of gait, gravity acting on the center of mass (CoM) causes a disequilibrium torque, which generates propulsive force. Triceps surae activity resists gravity by restraining forward tibial rotation thereby tuning CoM momentum. We hypothesized that time and amplitude modulation of triceps surae activity determines the kinematics (step length and cadence) and kinetics of gait. Nineteen young subjects participated in two experiments. In the gait initiation (GI) protocol, subjects deliberately initiated walking at different velocities for the same step length. In the balance‐recovery (BR) protocol, subjects executed steps of different length after being unexpectedly released from an inclined posture. Ground reaction force was recorded by a large force platform and electromyography of soleus, gastrocnemius medialis and lateralis, and tibialis anterior muscles was collected by wireless surface electrodes. In both protocols, the duration of triceps activity was highly correlated with single‐stance duration (GI, R2 = 0.68; BR, R2 = 0.91). In turn, step length was highly correlated with single‐stance duration (BR, R2 = 0.70). Control of CoM momentum was obtained by decelerating the CoM fall via modulation of amplitude of triceps activity. By modulation of triceps activity, the central nervous system (CNS) varied the position of CoM with respect to the center of pressure (CoP). The CoM‐CoP gap in the sagittal plane was determinant for setting the disequilibrium torque and thus walking velocity. Thus, by controlling the gap, CNS‐modified walking velocity (GI, R2 = 0.86; BR, R2 = 0.92). This study is the first to highlight that by merely counteracting gravity, triceps activity sets the kinematics and kinetics of gait. It also provides evidence that the surge in triceps activity during fast walking is due to the increased requirement of braking the fall of CoM in late stance in order to perform a smoother step‐to‐step transition. PMID:24744898
Three-Dimensional Ankle Moments and Nonlinear Summation of Rat Triceps Surae Muscles
Tijs, Chris; van Dieën, Jaap H.; Baan, Guus C.; Maas, Huub
2014-01-01
The Achilles tendon and epimuscular connective tissues mechanically link the triceps surae muscles. These pathways may cause joint moments exerted by each muscle individually not to sum linearly, both in magnitude and direction. The aims were (i) to assess effects of sagittal plane ankle angle (varied between 150° and 70°) on isometric ankle moments, in both magnitude and direction, exerted by active rat triceps surae muscles, (ii) to assess ankle moment summation between those muscles for a range of ankle angles and (iii) to assess effects of sagittal plane ankle angle and muscle activation on Achilles tendon length. At each ankle angle, soleus (SO) and gastrocnemius (GA) muscles were first excited separately to assess ankle-angle moment characteristics and subsequently both muscles were excited simultaneously to investigate moment summation. The magnitude of ankle moment exerted by SO and GA, the SO direction in the transverse and sagittal planes, and the GA direction in the transverse plane were significantly affected by ankle angle. SO moment direction in the frontal and sagittal planes were significantly different from that of GA. Nonlinear magnitude summation varied between 0.6±2.9% and −3.6±2.9%, while the nonlinear direction summation varied between 0.3±0.4° and −0.4±0.7° in the transverse plane, between 0.5±0.4° and 0.1±0.4° in the frontal plane, and between 3.0±7.9° and 0.3±2.3° in the sagittal plane. Changes in tendon length caused by SO contraction were significantly lower than those during contraction of GA and GA+SO simultaneously. Thus, moments exerted by GA and SO sum nonlinearly both in the magnitude and direction. The limited degree of nonlinear summation may be explained by different mechanisms acting in opposite directions. PMID:25360524
Khosrawi, Saeid; Fallah, Salman
2013-03-01
The H-reflex is a useful electrophysiological procedure for evaluating the status of the peripheral nervous system, especially at the proximal segment of the peripheral nerve. The purpose of this study is to investigate the relation between triceps surae H-reflex and M- response latencies and thigh length in normal population, in order to determine if there is any regression equation between them. After screening 75 volunteers by considering inclusion and exclusion criteria, 72 of them were selected to enroll into our study (34 men and 38 women with the mean age of 36.04 ± 7.7 years). In all of the subjects H-reflex and M-response latencies were recorded by standard electrophysiological techniques and thigh length was measured. Finally, our data was analyzed for its relations with respect to ages in both sexes by appropriate statistical and mathematical methods. Mean ± SD for H-reflex latency was 27.94 ± 1.6 ms. We found a significant correlation between H-reflex latency and M-latency (r = 0.28), no significant correlation was found between H-reflex latency and thigh length (r = -0.051). Finally based on our findings we introduce a new formula in this paper. We found a significant correlation among of M-response latency and other variables (H-reflex latency and thigh length). Despite this it was eliminated from our formula. The relationship between H-reflex latency and age was significant. Further studies are required to delineate the clinical usage and interpretation of the formula, which we found in this study.
Sura Yusuf in Full IPA (Segmental-Suprasegmental) Transcription with English Translation
ERIC Educational Resources Information Center
Yurtbasi, Metin
2016-01-01
The greatest difficulty in reading Arabic script for nonnatives is the absence of short vowels. The correlation of 28 consonants with sounds poses no great difficulty. In Arabic, there are six vowel phonemes which are voiced only by three letters with help of some relevant diacritical marks (?arakat). As the bulk of Arabic publications is written…
NASA Astrophysics Data System (ADS)
Shindin, Alexey; Nasyrov, Igor; Grach, Savely; Sergeev, Evgeny; Klimenko, Vladimir; Beletsky, Alexandr
We present results of artificial optical emission observations in the red (630 nm) and green (557.7 nm) lines of the atomic oxygen during ionosphere HF pumping at the Sura facility (56.1°N, 46.1°E, magnetic field dip angle 71.5°) in Sep. 2012. Pump wave (PW) of O-polarization at frequencies f0 = 4.74 - 5.64 MHz was used in the experiment according to ionospheric conditions after sunset. Two CCD cameras (S1C/079-FP(FU) and KEO Sentinel with fields of view 20° and 145°, respectively, and 3 photometers were used for the emission registration. For estimation of a relation between the PW frequency f0 and 4th electron gyroharmonic 4fce Stimulated Electromagnetic Emission (SEE) registration was applied (for details see [1]). On September 11 the pump beam was inclined by 12° to the South, the PW frequencies f0 = 5.40 and 5.42 MHz were slightly above 4fce. On September 13, for vertical pumping, f0 was 5.64 MHz (well above 4fce), 5.32 - 5.42 MHz (around 4fce) and 4.74 MHz (well below 4fce). On September 14 the vertical pumping at f0 = 5.30 - 5.36 MHz and 4.74 MHz was used. In the latter day due to natural motion of the ionosphere and concurrent SEE measurements we were able to obtain a fine dependence of the optical brightness on the proximity f0 and 4fce. For the red line no essential dependence, as well of the shape and position of the airglow spot on the proximity was obtained with one exception: on Sep. 14 when, according to the SEE spectra, f0 was just below 4fce (by 15-20 kHz), the brightness essentially increased, by 1.25-1.5 times. For the green line, the brightest emission occurred when f0 was passing through 4fce (Sep. 14) and when f0 = 5.64 MHz (Sep. 13, well above 4fce). Also, on Sep. 14 the airglow enhancement in the red line during the pumping was replaced by the suppression of the background emission when the ionosphere critical frequency approached to f0 by less than 500 kHz. Similar effect was obtained on Sep. 11 and in [2] for south-inclined pump beam, but never observed at the Sura facility for vertical pumping. The data of KEO Sentinel camera obtained on Sep. 11 have shown the suppression of the background existed even for vertical direction while the pump beam was South-inclined by 12° and the spot of enhanced airglow was observed, similar to [2], in the magnetic zenith. Note that earlier experiments near 4fce performed at EISCAT facility during previous Solar maximum did not show any clear dependence of the red and green line brightness of the relation between f0 and 4fce [3]. 1. Layser T.B. // Space Sci. Rev., V. 98, 223 (2001). 2. Grach S.M., et al. // Radiophys. Quantum Electron. V. 55, P. 33-50 (2012). 3. Gustavsson B., et al. // Phys. Rev. Lett., 97, 195002 (2006).
Gao, Fan; Ren, Yupeng; Roth, Elliot J.; Harvey, Richard; Zhang, Li-Qun
2011-01-01
Background The objective of this study was to investigate changes in active and passive biomechanical properties of the calf muscle-tendon unit induced by controlled ankle stretching in stroke survivors. Methods Ten stroke survivors with ankle spasticity/contracture and ten healthy control subjects received intervention of 60-min ankle stretching. Joint biomechanical properties including resistance torque, stiffness and index of hysteresis were evaluated pre- and post-intervention. Achilles tendon length was measured using ultrasonography. The force output of the triceps surae muscles was characterized via the torque-angle relationship, by stimulating the calf muscles at a controlled intensity across different ankle positions. Findings Compared to healthy controls, the ankle position corresponding to the peak torque of the stroke survivors was shifted towards plantar flexion (P<0.001). Stroke survivors showed significantly higher resistance torques and joint stiffness (P<0.05), and these higher resistances were reduced significantly after the stretching intervention, especially in dorsiflexion (P = 0.013). Stretching significantly improved the force output of the impaired calf muscles in stroke survivors under matched stimulations (P<0.05). Ankle range of motion was also increased by stretching (P<0.001). Interpretation At the joint level, repeated stretching loosened the ankle joint with increased passive joint range of motion and decreased joint stiffness. At the muscle-tendon level, repeated stretching improved calf muscle force output, which might be associated with decreased muscle fascicle stiffness, increased fascicle length and shortening of the Achilles tendon. The study provided evidence of improvement in muscle tendon properties through stretching intervention. PMID:21211873
Human spinal locomotor control is based on flexibly organized burst generators.
Danner, Simon M; Hofstoetter, Ursula S; Freundl, Brigitta; Binder, Heinrich; Mayr, Winfried; Rattay, Frank; Minassian, Karen
2015-03-01
Constant drive provided to the human lumbar spinal cord by epidural electrical stimulation can cause local neural circuits to generate rhythmic motor outputs to lower limb muscles in people paralysed by spinal cord injury. Epidural spinal cord stimulation thus allows the study of spinal rhythm and pattern generating circuits without their configuration by volitional motor tasks or task-specific peripheral feedback. To reveal spinal locomotor control principles, we studied the repertoire of rhythmic patterns that can be generated by the functionally isolated human lumbar spinal cord, detected as electromyographic activity from the legs, and investigated basic temporal components shared across these patterns. Ten subjects with chronic, motor-complete spinal cord injury were studied. Surface electromyographic responses to lumbar spinal cord stimulation were collected from quadriceps, hamstrings, tibialis anterior, and triceps surae in the supine position. From these data, 10-s segments of rhythmic activity present in the four muscle groups of one limb were extracted. Such samples were found in seven subjects. Physiologically adequate cycle durations and relative extension- and flexion-phase durations similar to those needed for locomotion were generated. The multi-muscle activation patterns exhibited a variety of coactivation, mixed-synergy and locomotor-like configurations. Statistical decomposition of the electromyographic data across subjects, muscles and samples of rhythmic patterns identified three common temporal components, i.e. basic or shared activation patterns. Two of these basic patterns controlled muscles to contract either synchronously or alternatingly during extension- and flexion-like phases. The third basic pattern contributed to the observed muscle activities independently from these extensor- and flexor-related basic patterns. Each bifunctional muscle group was able to express both extensor- and flexor-patterns, with variable ratios across the samples of rhythmic patterns. The basic activation patterns can be interpreted as central drives implemented by spinal burst generators that impose specific spatiotemporally organized activation on the lumbosacral motor neuron pools. Our data thus imply that the human lumbar spinal cord circuits can form burst-generating elements that flexibly combine to obtain a wide range of locomotor outputs from a constant, repetitive input. It may be possible to use this flexibility to incorporate specific adaptations to gait and stance to improve locomotor control, even after severe central nervous system damage. © The Author (2015). Published by Oxford University Press on behalf of the Guarantors of Brain. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Human spinal locomotor control is based on flexibly organized burst generators
Danner, Simon M.; Hofstoetter, Ursula S.; Freundl, Brigitta; Binder, Heinrich; Mayr, Winfried; Rattay, Frank
2015-01-01
Constant drive provided to the human lumbar spinal cord by epidural electrical stimulation can cause local neural circuits to generate rhythmic motor outputs to lower limb muscles in people paralysed by spinal cord injury. Epidural spinal cord stimulation thus allows the study of spinal rhythm and pattern generating circuits without their configuration by volitional motor tasks or task-specific peripheral feedback. To reveal spinal locomotor control principles, we studied the repertoire of rhythmic patterns that can be generated by the functionally isolated human lumbar spinal cord, detected as electromyographic activity from the legs, and investigated basic temporal components shared across these patterns. Ten subjects with chronic, motor-complete spinal cord injury were studied. Surface electromyographic responses to lumbar spinal cord stimulation were collected from quadriceps, hamstrings, tibialis anterior, and triceps surae in the supine position. From these data, 10-s segments of rhythmic activity present in the four muscle groups of one limb were extracted. Such samples were found in seven subjects. Physiologically adequate cycle durations and relative extension- and flexion-phase durations similar to those needed for locomotion were generated. The multi-muscle activation patterns exhibited a variety of coactivation, mixed-synergy and locomotor-like configurations. Statistical decomposition of the electromyographic data across subjects, muscles and samples of rhythmic patterns identified three common temporal components, i.e. basic or shared activation patterns. Two of these basic patterns controlled muscles to contract either synchronously or alternatingly during extension- and flexion-like phases. The third basic pattern contributed to the observed muscle activities independently from these extensor- and flexor-related basic patterns. Each bifunctional muscle group was able to express both extensor- and flexor-patterns, with variable ratios across the samples of rhythmic patterns. The basic activation patterns can be interpreted as central drives implemented by spinal burst generators that impose specific spatiotemporally organized activation on the lumbosacral motor neuron pools. Our data thus imply that the human lumbar spinal cord circuits can form burst-generating elements that flexibly combine to obtain a wide range of locomotor outputs from a constant, repetitive input. It may be possible to use this flexibility to incorporate specific adaptations to gait and stance to improve locomotor control, even after severe central nervous system damage. PMID:25582580
2013-01-01
Background Spastic paresis in cerebral palsy (CP) is characterized by increased joint stiffness that may be of neural origin, i.e. improper muscle activation caused by e.g. hyperreflexia or non-neural origin, i.e. altered tissue viscoelastic properties (clinically: “spasticity” vs. “contracture”). Differentiation between these components is hard to achieve by common manual tests. We applied an assessment instrument to obtain quantitative measures of neural and non-neural contributions to ankle joint stiffness in CP. Methods Twenty-three adolescents with CP and eleven healthy subjects were seated with their foot fixated to an electrically powered single axis footplate. Passive ramp-and-hold rotations were applied over full ankle range of motion (RoM) at low and high velocities. Subject specific tissue stiffness, viscosity and reflexive torque were estimated from ankle angle, torque and triceps surae EMG activity using a neuromuscular model. Results In CP, triceps surae reflexive torque was on average 5.7 times larger (p = .002) and tissue stiffness 2.1 times larger (p = .018) compared to controls. High tissue stiffness was associated with reduced RoM (p < .001). Ratio between neural and non-neural contributors varied substantially within adolescents with CP. Significant associations of SPAT (spasticity test) score with both tissue stiffness and reflexive torque show agreement with clinical phenotype. Conclusions Using an instrumented and model based approach, increased joint stiffness in CP could be mainly attributed to higher reflexive torque compared to control subjects. Ratios between contributors varied substantially within adolescents with CP. Quantitative differentiation of neural and non-neural stiffness contributors in CP allows for assessment of individual patient characteristics and tailoring of therapy. PMID:23880287
de Gooijer-van de Groep, Karin L; de Vlugt, Erwin; de Groot, Jurriaan H; van der Heijden-Maessen, Hélène C M; Wielheesen, Dennis H M; van Wijlen-Hempel, Rietje M S; Arendzen, J Hans; Meskers, Carel G M
2013-07-23
Spastic paresis in cerebral palsy (CP) is characterized by increased joint stiffness that may be of neural origin, i.e. improper muscle activation caused by e.g. hyperreflexia or non-neural origin, i.e. altered tissue viscoelastic properties (clinically: "spasticity" vs. "contracture"). Differentiation between these components is hard to achieve by common manual tests. We applied an assessment instrument to obtain quantitative measures of neural and non-neural contributions to ankle joint stiffness in CP. Twenty-three adolescents with CP and eleven healthy subjects were seated with their foot fixated to an electrically powered single axis footplate. Passive ramp-and-hold rotations were applied over full ankle range of motion (RoM) at low and high velocities. Subject specific tissue stiffness, viscosity and reflexive torque were estimated from ankle angle, torque and triceps surae EMG activity using a neuromuscular model. In CP, triceps surae reflexive torque was on average 5.7 times larger (p = .002) and tissue stiffness 2.1 times larger (p = .018) compared to controls. High tissue stiffness was associated with reduced RoM (p < .001). Ratio between neural and non-neural contributors varied substantially within adolescents with CP. Significant associations of SPAT (spasticity test) score with both tissue stiffness and reflexive torque show agreement with clinical phenotype. Using an instrumented and model based approach, increased joint stiffness in CP could be mainly attributed to higher reflexive torque compared to control subjects. Ratios between contributors varied substantially within adolescents with CP. Quantitative differentiation of neural and non-neural stiffness contributors in CP allows for assessment of individual patient characteristics and tailoring of therapy.
Bernabei, Michel; van Dieën, Jaap H; Maas, Huub
2017-02-15
The functional consequences of differential muscle activation and contractile behavior between mechanically coupled synergists are still poorly understood. Even though synergistic muscles exert similar mechanical effects at the joint they span, differences in the anatomy, morphology and neural drive may lead to non-uniform contractile conditions. This study aimed to investigate the patterns of activation and contractile behavior of triceps surae muscles, to understand how these contribute to the relative displacement between the one-joint soleus (SO) and two-joint lateral gastrocnemius (LG) muscle bellies and their distal tendons during locomotion in the rat. In seven rats, muscle belly lengths and muscle activation during level and upslope trotting were measured by sonomicrometry crystals and electromyographic electrodes chronically implanted in the SO and LG. Length changes of muscle-tendon units (MTUs) and tendon fascicles were estimated based on joint kinematics and muscle belly lengths. Distances between implanted crystals were further used to assess longitudinal and transversal deformations of the intermuscular volume between the SO and LG. For both slope conditions, we observed differential timing of muscle activation as well as substantial differences in contraction speeds between muscle bellies (maximal relative speed 55.9 mm s -1 ). Muscle lengths and velocities did not differ significantly between level and upslope locomotion, only EMG amplitude of the LG was affected by slope. Relative displacements between SO and LG MTUs were found in both longitudinal and transversal directions, yielding an estimated maximal length change difference of 2.0 mm between their distal tendons. Such relative displacements may have implications for the force exchanged via intermuscular and intertendinous pathways. © 2017. Published by The Company of Biologists Ltd.
Anloague, Philip A; Strack, Donald S
2018-05-01
Study Design Case report. Background Acute injuries of the triceps surae and Achilles tendon are common in sports. Rupture of the plantaris tendon can be challenging to diagnose. There is limited evidence detailing the diagnosis, rehabilitation, and accelerated return to sport of elite professional basketball players who have sustained calf injuries. Case Description A 25-year-old male professional basketball player sustained an injury to his calf during a professional basketball game. This case report details the presumptive diagnosis, graduated progression of intervention, and return to play of a professional athlete with a likely isolated plantaris tendon tear. Outcomes The patient returned to postseason competition 10 days post injury. Objective measures were tracked throughout rehabilitation and compared to baseline assessments. Before returning to play, the athlete showed improvements beyond the minimal clinically important difference for calf girth (2 cm) and numeric pain-rating scale score (4 points, 0-10 scale). Functional testing was conducted that included the Y Balance Test lower quarter and the Functional Movement Screen, with results that exceeded or returned the athlete to preseason levels. Discussion This report details the case of a professional basketball player who returned to competitive play in an accelerated time frame following injury to his calf. Diagnosing a plantaris tendon rupture can be challenging, and anatomical variations of this muscle should be considered. It was demonstrated in this case that physical therapy rehabilitation was helpful in making a treatment-based clinical diagnosis when imaging was unclear. Level of Evidence Therapy, level 5. J Orthop Sports Phys Ther 2018;48(5):388-397. Epub 6 Apr 2018. doi:10.2519/jospt.2018.7192.
Hamada, Taku; Hayashi, Tatsuya; Kimura, Tetsuya; Nakao, Kazuwa; Moritani, Toshio
2004-03-01
Our laboratory has recently demonstrated that low-frequency electrical stimulation (ES) of quadriceps muscles alone significantly enhanced glucose disposal rate (GDR) during euglycemic clamp (Hamada T, Sasaki H, Hayashi T, Moritani T, and Nakao K. J Appl Physiol 94: 2107-2112, 2003). The present study is further follow-up to examine the acute metabolic effects of ES to lower extremities compared with voluntary cycle exercise (VE) at identical intensity. In eight male subjects lying in the supine position, both lower leg (tibialis anterior and triceps surae) and thigh (quadriceps and hamstrings) muscles were sequentially stimulated to cocontract in an isometric manner at 20 Hz with a 1-s on-off duty cycle for 20 min. Despite small elevation of oxygen uptake by 7.3 +/- 0.3 ml x kg(-1) x min(-1) during ES, the blood lactate concentration was significantly increased by 3.2 +/- 0.3 mmol/l in initial period (5 min) after the onset of the ES (P < 0.01), whereas VE showed no such changes at identical oxygen uptake (7.5 +/- 0.3 ml x kg(-1) x min(-1)). ES also induced enhanced whole body carbohydrate oxidation as shown by the significantly higher respiratory gas exchange ratio than with VE (P < 0.01). These data indicated increased anaerobic glycolysis by ES. Furthermore, whole body glucose uptake determined by GDR during euglycemic clamp demonstrated a significant increase during and after the cessation of ES for at least 90 min (P < 0.01). This post-ES effect was significantly greater than that of the post-VE period (P < 0.01). These results suggest that ES can substantially enhance energy consumption, carbohydrate oxidation, and whole body glucose uptake at low intensity of exercise. Percutaneous ES may become a therapeutic utility to enhance glucose metabolism in humans.
A Predictive Mathematical Model of Muscle Forces for Children with Cerebral Palsy
ERIC Educational Resources Information Center
Lee, Samuel C. K.; Ding, Jun; Prosser, Laura A.; Wexler, Anthony S.; Binder-Macleod, Stuart A.
2009-01-01
Aim: The purpose of this study was to determine if our previously developed muscle model could be used to predict forces of the quadriceps femoris and triceps surae muscles of children with spastic diplegic cerebral palsy (CP). Method: Twenty-two children with CP (12 males, 10 females; mean age 10y, SD 2y, range 7-13y; Gross Motor Function…
Heating Capacity of ReBound Shortwave Diathermy and Moist Hot Packs at Superficial Depths
Hawkes, Amanda R.; Draper, David O.; Johnson, A. Wayne; Diede, Mike T.; Rigby, Justin H.
2013-01-01
Context: The effectiveness of a new continuous diathermy unit, ReBound, as a heating modality is unknown. Objective: To compare the effects of ReBound diathermy with silicate-gel moist hot packs on tissue temperature in the human triceps surae muscle. Design: Crossover study. Setting: University research laboratory. Patients or Other Participants: A total of 12 healthy, college-aged volunteers (4 men, 8 women; age = 22.2 ± 2.25 years, calf subcutaneous fat thickness = 7.2 ± 1.9 mm). Intervention(s): On 2 different days, 1 of 2 modalities (ReBound diathermy, silicate-gel moist hot pack) was applied to the triceps surae muscle of each participant for 30 minutes. After 30 minutes, the modality was removed, and temperature decay was recorded for 20 minutes. Main Outcome Measure(s): Medial triceps surae intramuscular tissue temperature at a depth of 1 cm was measured using an implantable thermocouple inserted horizontally into the muscle. Measurements were taken every 5 minutes during the 30-minute treatment and every minute during the 20-minute temperature decay, for a total of 50 minutes. Treatment was analyzed through a 2 × 7 mixed-model analysis of variance with repeated measures. Temperature decay was analyzed through a 2 × 21 mixed-model analysis of variance with repeated measures. Results: During the 30-minute application, tissue temperatures at a depth of 1 cm increased more with the ReBound diathermy than with the moist hot pack (F6,66 = 7.14, P < .001). ReBound diathermy and moist hot packs increased tissue temperatures 3.69°C ± 1.50°C and 2.82°C ± 0.90°C, respectively, from baseline. Throughout the temperature decay, ReBound diathermy produced a greater rate of heat dissipation than the moist hot pack (F20,222 = 4.42, P < .001). Conclusions: During a 30-minute treatment at a superficial depth, the ReBound diathermy increased tissue temperature to moderate levels, which were greater than the levels reached with moist hot packs. PMID:23855362
Electrically induced muscle cramps induce hypertrophy of calf muscles in healthy adults.
Behringer, M; Moser, M; Montag, J; McCourt, M; Tenner, D; Mester, J
2015-06-01
Skeletal muscles usually cramp at short lengths, where the tension that can be exerted by muscle fibers is low. Since high tension is an important anabolic stimulus, it is questionable if cramps can induce hypertrophy and strength gains. In the present study we investigated if electrically induced cramps (EIMCs) can elicit these adaptations. 15 healthy male adults were randomly assigned to an intervention (IG; n=10) and a control group (CG; n=5). The cramp protocol (CP) applied twice a week to one leg of the IG, consisted of 3x6 EIMCs, of 5 s each. Calf muscles of the opposite leg were stimulated equally, but were hindered from cramping by fixating the ankle at 0° plantar flexion (nCP). After six weeks, the cross sectional area of the triceps surae was similarly increased in both the CP (+9.0±3.4%) and the nCP (+6.8±3.7%). By contrast, force of maximal voluntary contractions, measured at 0° and 30° plantar flexion, increased significantly only in nCP (0°: +8.5±8.8%; 30°: 11.7±13.7%). The present data indicate that muscle cramps can induce hypertrophy in calf muscles, though lacking high tension as an important anabolic stimulus.
Electrically induced muscle cramps induce hypertrophy of calf muscles in healthy adults
Behringer, M.; Moser, M.; Montag, J.; McCourt, M.; Tenner, D.; Mester, J.
2015-01-01
Objectives: Skeletal muscles usually cramp at short lengths, where the tension that can be exerted by muscle fibers is low. Since high tension is an important anabolic stimulus, it is questionable if cramps can induce hypertrophy and strength gains. In the present study we investigated if electrically induced cramps (EIMCs) can elicit these adaptations. Methods: 15 healthy male adults were randomly assigned to an intervention (IG; n=10) and a control group (CG; n=5). The cramp protocol (CP) applied twice a week to one leg of the IG, consisted of 3x6 EIMCs, of 5 s each. Calf muscles of the opposite leg were stimulated equally, but were hindered from cramping by fixating the ankle at 0° plantar flexion (nCP). Results: After six weeks, the cross sectional area of the triceps surae was similarly increased in both the CP (+9.0±3.4%) and the nCP (+6.8±3.7%). By contrast, force of maximal voluntary contractions, measured at 0° and 30° plantar flexion, increased significantly only in nCP (0°: +8.5±8.8%; 30°: 11.7±13.7%). Conclusion: The present data indicate that muscle cramps can induce hypertrophy in calf muscles, though lacking high tension as an important anabolic stimulus. PMID:26032216
Wokke, B H; van den Bergen, J C; Versluis, M J; Niks, E H; Milles, J; Webb, A G; van Zwet, E W; Aartsma-Rus, A; Verschuuren, J J; Kan, H E
2014-05-01
The purpose of this study was to assess leg muscle quality and give a detailed description of leg muscle involvement in a series of Duchenne muscular dystrophy patients using quantitative MRI and strength measurements. Fatty infiltration, as well as total and contractile (not fatty infiltrated) cross sectional areas of various leg muscles were determined in 16 Duchenne patients and 11 controls (aged 8-15). To determine specific muscle strength, four leg muscle groups (quadriceps femoris, hamstrings, anterior tibialis and triceps surae) were measured and related to the amount of contractile tissue. In patients, the quadriceps femoris showed decreased total and contractile cross sectional area, attributable to muscle atrophy. The total, but not the contractile, cross sectional area of the triceps surae was increased in patients, corresponding to hypertrophy. Specific strength decreased in all four muscle groups of Duchenne patients, indicating reduced muscle quality. This suggests that muscle hypertrophy and fatty infiltration are two distinct pathological processes, differing between muscle groups. Additionally, the quality of remaining muscle fibers is severely reduced in the legs of Duchenne patients. The combination of quantitative MRI and quantitative muscle testing could be a valuable outcome parameter in longitudinal studies and in the follow-up of therapeutic effects. Copyright © 2014 Elsevier B.V. All rights reserved.
Within-step modulation of leg muscle activity by afferent feedback in human walking
Klint, Richard af; Nielsen, Jens Bo; Cole, Jonathan; Sinkjaer, Thomas; Grey, Michael J
2008-01-01
To maintain smooth and efficient gait the motor system must adjust for changes in the ground on a step-to-step basis. In the present study we investigated the role of sensory feedback as 19 able-bodied human subjects walked over a platform that mimicked an uneven supporting surface. Triceps surae muscle activation was assessed during stance as the platform was set to different inclinations (±3 deg, ±2 deg and 0 deg rotation in a parasagittal plane about the ankle). Normalized triceps surae muscle activity was significantly increased when the platform was inclined (2 deg: 0.153 ± 0.051; 3 deg: 0.156 ± 0.053) and significantly decreased when the platform was declined (−3 deg: 0.133 ± 0.048; −2 deg: 0.132 ± 0.049) compared with level walking (0.141 ± 0.048) for the able-bodied subjects. A similar experiment was performed with a subject who lacked proprioception and touch sensation from the neck down. In contrast with healthy subjects, no muscle activation changes were observed in the deafferented subject. Our results demonstrate that the ability to compensate for small irregularities in the ground surface relies on automatic within-step sensory feedback regulation rather than conscious predictive control. PMID:18669536
A New Approach to Estimate the Age of the Earth and the Age of the Universe
NASA Astrophysics Data System (ADS)
Ben Salem, Kamel
2011-01-01
In a previous article, we proposed estimations for the age of the Universe and for the date of stabilization of its general structure on the basis of a given age of the Earth equal to 4.6 billion years. In the present article, we propose a new approach to estimate more accurately and at the same time, the age of the Earth and that of the Universe, starting from verse 4 of Sura 70 of the Qur'an. The procedure we followed and which is detailed in this article, should in our view, contribute to enlighten the debate on the question. We must add that our approach can in no case be considered as based on "concordism" or conjecture. Indeed, it rests on rigorous mathematical computations.
Is there an association between the use of heeled footwear and schizophrenia?
Flensmark, Jarl
2004-01-01
Existing etiological and pathogenetical theories of schizophrenia have only been able to find support in some epidemiological, clinical, and pathophysiological facts. A selective literature review and synthesis is used to present a hypothesis that finds support in all facts and is contradicted by none. Heeled footwear began to be used more than a 1000 years ago, and led to the occurrence of the first cases of schizophrenia. Industrialization of shoe production increased schizophrenia prevalence. Mechanization of the production started in Massachusetts, spread from there to England and Germany, and then to the rest of Western Europe. A remarkable increase in schizophrenia prevalence followed the same pattern. In Baden in Germany the increasing stream of young patients more or less hastily progrediating to a severe state of cognitive impairment made it possible for Kraepelin to delineate dementia praecox as a nosological entity. The patients continued to use heeled shoes after they were admitted to the hospitals and the disease progrediated. High rates of schizophrenia are found among first-generation immigrants from regions with a warmer climate to regions with a colder climate, where the use of shoes is more common. Still higher rates among second-generation immigrants are caused by the use of shoes during the onset of walking at an age of about 11-12 months. Other findings point to the importance of this in the later development of schizophrenia. A child born in January-March begins to walk in December-March, when it's cold outside and the chances of going barefoot are smaller. They are also smaller in urban settings. During walking synchronised stimuli from mechanoreceptors in the lower extremities increase activity in cerebello-thalamo-cortico-cerebellar loops through their action on NMDA-receptors. Using heeled shoes leads to weaker stimulation of the loops. Reduced cortical activity changes dopaminergic function which involves the basal ganglia-thalamo-cortical-nigro-basal ganglia loops. Bicycle riding reduces depression in schizophrenia due to stronger stimulation by improved lengthening contractions of the triceps surae muscles. Electrode stimulation of cerebellar loops normally stimulated by mechanoreceptors in the lower extremities could improve functioning in schizophrenia. Cross-sectional prevalence studies of the association between the use of heeled footwear and schizophrenia should be made in immigrants from regions with a warmer climate or in groups of people who began to wear shoes at different ages. Copyright 2004 Elsevier Ltd.
Moral Obligation and the Military: Collected Essays
1988-01-01
millenial expectations of the second com- ing of the Christ and placed these expectations on earth. The problem to be addressed is how do you change (get rid...of Allah his forgiveness and his mercy would surely be better than all the riches the infidels amass. (Sura iii) 113 Jake R. Hensinan Violence...last of these-the people-that represents the culmination of the strategy as executed by William Tecumseh Sherman. We "must make old and young, rich and
Masood, Tahir; Kalliokoski, Kari; Bojsen-Møller, Jens; Finni, Taija
2016-09-01
Achilles tendon rupture (ATR) is the most common tendon rupture injury. The consequences of ATR on metabolic activity of the Achilles tendon and ankle plantarflexors are unknown. Furthermore, the effects of eccentric rehabilitation on metabolic activity patterns of Achilles tendon and ankle plantarflexors in ATR patients have not been reported thus far. We present a case study demonstrating glucose uptake (GU) in the Achilles tendon, the triceps surae, and the flexor hallucis longus of a post-surgical ATR patient before and after a 5-month eccentric rehabilitation. At baseline, three months post-surgery, all muscles and Achilles tendon displayed much higher GU in the ATR patient compared to a healthy individual despite lower plantarflexion force. After the rehabilitation, plantarflexion force increased in the operated leg while muscle GU was considerably reduced. The triceps surae muscles showed similar values to the healthy control. When compared to the healthy or a matched patient with Achilles tendon pain after 12 weeks of rehabilitation, Achilles tendon GU levels of ATR patient remained greater after the rehabilitation. Past studies have shown a shift in the metabolic fuel utilization towards glycolysis due to immobilization. Further research, combined with immuno-histological investigation, is needed to fully understand the mechanism behind excessive glucose uptake in ATR cases. Copyright © 2015 Elsevier Ltd. All rights reserved.
Kuamsub, Sirigoon; Singthong, Pariyaphat; Chanthasri, Wipawee; Chobngam, Nicharee; Sangkaew, Warissara; Hemdecho, Sasithorn; Kaewmanee, Thammarat
2017-01-01
Tri-Sura-Phon (TSP), a traditional Thai polyherbal formula renowned for its rejuvenating properties, is commonly used as a blood tonic. It comprises Cinnamomum bejolghota, Cinnamomum parthenoxylon, and Aquilaria crassna. The aim of this study is to evaluate the beneficial properties of TSP tea consumption on blood glucose regulation and serum lipid profiles of healthy overweight volunteers. This open-label, randomized controlled trial was conducted in 70 healthy overweight adults. Two groups of 35 subjects took a TSP infusion or a placebo (cornstarch) twice daily for 8 weeks. The blood glucose regulation, serum lipid profiles, BMI, and liver function tests of the subjects were determined at the baseline, 4th week, and endpoint (8th week). Significant decreases in the average fasting levels of total cholesterol (p = 0.013), triglyceride (p = 0.001), and low-density lipoprotein (LDL, p = 0.017) were observed in the TSP group at the 8th week compared to those at the baseline. The average HDL level in the TSP group at the beginning of the study was 65.2 mg/dL, and it increased significantly (p = 0.005) to 72.4 mg/dL after 8 weeks of TSP intake. This study showed that the intake of TSP tea as an antioxidant-rich beverage might be safe and improve lipid profiles in overweight adults. PMID:28484502
Dynamic properties of ionospheric plasma turbulence driven by high-power high-frequency radiowaves
NASA Astrophysics Data System (ADS)
Grach, S. M.; Sergeev, E. N.; Mishin, E. V.; Shindin, A. V.
2016-11-01
A review is given of the current state-of-the-art of experimental studies and the theoretical understanding of nonlinear phenomena that occur in the ionospheric F-layer irradiated by high-power high-frequency ground-based transmitters. The main focus is on the dynamic features of high-frequency turbulence (plasma waves) and low-frequency turbulence (density irregularities of various scales) that have been studied in experiments at the Sura and HAARP heating facilities operated in temporal and frequency regimes specially designed with consideration of the characteristic properties of nonlinear processes in the perturbed ionosphere using modern radio receivers and optical instruments. Experimental results are compared with theoretical turbulence models for a magnetized collisional plasma in a high-frequency electromagnetic field, allowing the identification of the processes responsible for the observed features of artificial ionospheric turbulence.
NASA Astrophysics Data System (ADS)
Frolov, Vladimir; Rauch, Jean-Louis; Parrot, Michel; Rapoport, Victor; Shorokhova, Elena
In the report we consider features of plasma density and electro-magnetic field perturbations induced in the Earth’s outer ionosphere by modification of F _{2} region by O-mode powerful HF radio waves radiated by the SURA heating facility. Experiments presented were carried out in 2005 - 2010. Plasma density perturbations were detected at altitudes of about of 700 km by instruments onboard the French DEMETER satellite when it intersected the disturbed magnetic flux tube. The formation of artificial HF-induced plasma density ducts in the outer ionosphere is a central discovery, which was made during the SURA-DEMETER experiments [1,2]. Analysis of experimental data available makes it possible to formulate ducts features and point out the conditions under which the formation of such ducts takes place. 1. Under night conditions ducts are characterized by the increased plasma density in the range from 20% to 80% relatively to its background value. As this takes place, the excess in the plasma ion component is due to O (+) ions dominating at altitudes of about 700 km, whereas the densities of lower mass H (+) and He ({+) } ions typically decrease by a percentage amount that is much more the relative increase in the density of O (+) ions. The duct formation was never observed under daytime conditions. According to [3] the HF-induced ducts were observed by ionosphere pumping in morning and evening hours but in these cases their intensity was no more than a few percentages. 2. The size of the ducts along the satellite orbits is of about 80 - 100 km. It is a reason why such ducts can be observed only if the minimal distance between the satellite and the center of the heated flux tube is less than 50 km. 3. The formation of ducts is observed only if the effective radiated power is more than 40 MW. For the SURA facility, to heat the ionosphere at higher efficiency due to the “magnetic-zenith effect”, the HF beam is often inclined by 12 - 16(°) southward. 4. The pump wave frequency should be no less than 0.5 - 0.7 MHz below the F _{2} layer critical frequency f _{0F2}. In the opposed case the penetration of the radiated power behind the F _{2} ionospheric layer can take place [4]. 5. Strong variations of the electron temperature are observed inside the ducts, at the same time the ion temperature is unchanged. 6. A feature of the ducts is the presence of strong electro-magnetic field fluctuations in a frequency range from a few Hz to tens of kHz [1,5]. 7. It was revealed that the formation of the ducts in the outer ionosphere can stimulate the precipitation of energetic electrons with E ≥ 100 keV from the Earth’s radiation belts [6]. The work was supported by RFBR grants (## 12-05-00312, 13-02-12074, 13-02-12241) and by the scientific program “Geophysics”. References: 1. Rapoport V.O., V.L. Frolov, G.P. Komrakov, et al. // Radiophysics and Quantum Electronics, 2007. Vol. 50(8), p. 645. 2. Frolov V.L., V.O. Rapoport, G.P. Komrakov, et. al. // JETP Letters, 2008. Vol. 88, No. 12, p. 790. 3. Frolov V.L., I.A. Bolotin, V.O. Rapoport, et. al. // XXIV All-Russian conference “Radio Wave Propagation”. Irkutsk, 2014 (submitted for publication). 4. Frolov V.L., N.A. Mityakov, E.A. Shorokhova, M. Parrot. // Radiophysics and Quantum Electronics, 2013. Vol. 56(6), p. 325. 5. Rapoport V.O., V.L. Frolov, S.V. Polyakov, et al. // J. Geophys. Res., 2010. Vol. 115, A10322, doi:10.1029/2010JA015484. 6. Markov G.A., A.S. Belov, V.L. Frolov, et al. // JETPh, 2010. Vol. 138, No. 6(12), p. 1037.
Possibility of weather and climate change by active experiments
NASA Astrophysics Data System (ADS)
Avakyan, Sergey; Voronin, Nikolai; Troitsky, Arkadil; Chernouss, Sergey
The anonymous remote impact on weather and climatic characteristics permanently discussed in last decade despite the fact that the UN Convention forbid to use the weather as a weapon since the 1970's. For example, Ross N. Hoffman proposed to operate weather conditions by direct flux of microwave radiation from space. This flux could affects on water vapor in the troposphere. The development of an optically thin cirrus cloud is especially promising situation because even the formation of the aeroplane cirrus-track can stimulate disturbance, which is necessary to development of an initial cyclone stage. Our studies confirmed the results of experiments of NIRFI on sporadic appearance of the microwave radiation of ionospheric nature during periods of solar flares and geomagnetic storms, and also during work of the "Sura” ionospheric heating facility. Such microwave radiation also occurs, when precipitation of particles from radiation belts stimulated by work of powerful (˜ 1 MW) navigation transmitters at frequencies ˜ 5 - 22 kHz. This effect was discovered by measurements at the Intercosmos satellite Bulgaria-1300 in 1982, and recently was confirmed by the spacecraft DEMETER measurements Leningrad State University measurements 1990-1991 at altitude about 2100 m proved the impact of microwave radiation from solar radiobursts on the amount of water vapor in the upper troposphere column. 25 - 40% of the vapour are involved into the formation of clusters decreased an atmospheric transparency. Papers of State Optical Institute (2008) proposed to account the electron-stimulated precipitation from the radiation belts over powerful radio transmitters (registered on the spacecraft DEMETER) as an additional source of microwave radiation of the ionosphere. This source can participate in the condensation-cluster mechanism changes of atmospheric transparency by the same way as natural geomagnetic storm. (Grach et al) also recorded stream microwave ionospheric disturbance stimulated by HF heating in an experiment at the "Sura" even earlier (2002) This led to the appearance of Rydberg states exited by the accelerated electrons impact (Troitskii et al.) found that at the threshold of sensitivity of radiometric measurements in 0.006 g/cm(2) observed a decrease in the water vapor content in the troposphere at 0.05 g/cm(2) at a total natural content 1.8-2.1 g/cm(2) in a special experiment on the basis of "Sura" facility to study the cluster-condensation mechanism. These reductions were observed almost simultaneously with the work of facility and time delay was about 1 minute. It should be noted that the heating power was 20 times less than the maximal reached power in such facilities. The extending of the experimental possibilities on the clustering in the troposphere by ionospheric microwave radiation (SPbSU) supposedly can give us the same result as an active impact on the ionosphere by heating facilities and power transmitters. We believe that manifestation of the described effects give a contribution to change of climatic characteristics: cloud formation, cyclogenesis, temperature anomalies and precipitation. This follows from the results of the analysis of correlation between cloud cover, temperature and precipitation and solar-geomagnetic activity over secular and annual (2 - 5 years) scales. Authors propose to use an optical method for detecting emissions of atomic oxygen in those electronic transitions between Rydberg states, which wavelengths are located in the atmospheric spectral windows in the visible and IR ranges. It will be the test for contribution of the Rydberg excitation processes in the formation of the flux of microwave active effects of the ionosphere. Corresponding lines for the visible region of the spectrum in low-lying Rydberg levels (with principal quantum number n of about 10) are in the blue region of the spectrum: 448.4 nm (the electronic transition is 11d - 3p), 452,3 nm (10d - 3p), and 457.7 nm (9d - 3p). Application of the optical recording channel in active experiments (i.e., at a fixed space-time artificial ionospheric disturbances) allow: - to confirm experimentally the Rydberg channel of generating microwave fluxes from the ionosphere at its perturbations; - to offer remote monitoring as international control of sources of artificial influence on weather and climatic characteristics.
Response of mesospheric ozone to the heating of the lower ionosphere by high-power HF radio emission
NASA Astrophysics Data System (ADS)
Kulilov, Yu. Yu.; Frolov, V. L.; Grigor'ev, G. I.; Demkin, V. M.; Komrakov, G. P.; Krasilnokov, A. A.; Ryskin, V. G.
2013-01-01
We detected a decrease in the intensity of microwave radiation at the atmospheric ozone line at a frequency of 110836.04 MHz during ionospheric modification by high-power HF radiowaves radiated by the Sura Ionospheric Heating Facility. The obtained experimental data allowed us to hypothesize that this effect was caused by the fact that mesospheric ozone was affected by internal gravity waves generated in the E region of the ionosphere during its high-power HF radiowave heating.
2007-03-31
of task analysis for human-computer interaction. Mahwah, NJ: Lawrence Erlbaum Associates. Haupt, T . A., Henley, G ., Sura, B., Kirkland, R., Floyd...foulée de sa récente activité de planification stratégique, la Marine canadienne planifie actuellement une restructuration importante de ses...of a new warship) require that planning must begin now. Defence Research and Development Canada – Toronto (DRDC- T ) has recognized the important role
2007-03-31
of task analysis for human-computer interaction. Mahwah, NJ: Lawrence Erlbaum Associates. Haupt, T . A., Henley, G ., Sura, B., Kirkland, R., Floyd...foulée de sa récente activité de planification stratégique, la Marine canadienne planifie actuellement une restructuration importante de ses...of a new warship) require that planning must begin now. Defence Research and Development Canada – Toronto (DRDC- T ) has recognized the important role
Formation of artificial plasma disturbances in the lower ionosphere
NASA Astrophysics Data System (ADS)
Bakhmet'eva, N. V.; Frolov, V. L.; Vyakhirev, V. D.; Kalinina, E. E.; Bolotin, I. A.; Akchurin, A. D.; Zykov, E. Yu.
2012-06-01
We present the results of experiments on sounding the disturbed ionospheric region produced by the high-power RF radiation of the "Sura" heating facility, which were performed simultaneously at two observation points. One point is located on the territory of the heating facility the other, and the other, at the observatory of Kazan State University (the "Observatory" point) in 170 km to the East from the facility. The experiments were aimed at studying the mechanism of formation of artificial disturbances in the lower ionosphere in the case of reflection of a high-power wave in the F region and determining the parameters of the signals of backscattering from artificial electron density irregularities which are formed as a result of ionospheric perturbations. The ionosphere was modified by a high-power RF O-mode wave, which was emitted by the transmitters of the "Sura" facility, in sessions several seconds or minutes long. The disturbed region was sounded using the vertical-sounding technique at the "Vasil'sursk" laboratory by the partial-reflection facility at a frequency of 2.95 MHz, and by the modified ionospheric station "Tsiklon" at ten frequencies ranged from 2 to 6.5 MHz at the "Observatory" point. At the same time, vertical-sounding ionograms were recorded in the usual regime. At the reception points, simultaneous changes in the amplitudes of the vertical-sounding signals and the aspect backscattering signals were recorded. These records correlate with the periods of operation of the heating facility. The characteristics and dynamics of the signals are discussed.
Wele, Asmita A.; Pendse, Nikhil U.; Takle, Shrikant P.; Burase, Raghunath V.; Patil, Sanjay V.; Bhalerao, Supriya; Harsulkar, Abhay M.
2015-01-01
Introduction: Vasarishta built upon Mritasanjeevani Sura (MS) is a polyherbal hydro-alcoholic anti-asthmatic formulation which is administered in a dose of 1 ml instead of standard dose 40 ml, generally advocated for any “Asava–Arishta” in Ayurveda. Aim: The present study was aimed at finding out rationale for the peculiar distillation process to manufacture MS followed by Sthapana process to make Vasarishta. It was further aimed to find out difference in Vasarishta samples manufactured by purely fermentation process and the peculiar method mentioned above. Materials and Methods: Three batches of MS and subsequently three batches of Vasarishta were prepared. Basic standardization and development of standard operating procedure for the same were achieved by doing pH, percentage of alcohol and total reducing sugar, specific gravity on both MS and Vasarishta, during and after completion of process. Finally, MS and Vasarishta (built upon MS) made in laboratory were compared with marketed samples of MS and Vasarishta using gas chromatography. Results: The types of alcohols and volatile acids in MS and Vasarishta, prepared in laboratory, are similar but the proportions differ, which is taken as an indicator of process standardization. Values of furfural, ethyl acetate, and 1-butanol in lab samples are within permissible limits as against the values of the market samples. Conclusions: The textual process for the production of Vasarishta proved to produce organoleptically acceptable product which is virtually free of toxic compounds such as furfural. PMID:27313419
The First Arrow of Islam: The Confluence of Politics, Religion, and Culture in the Battle of Badr
2010-04-01
of the Islamic faith has to do with the afterlife . Muhammad wanted to give the Arabs around him reasons to fight because “the polytheist does not...The Quran builds on fate and links it to the afterlife in Sura 55:26 saying, “all those upon earth pass away; eternal is the face of thy Lord in...unique poetic themes. By using the owl as a central motif, Homerin describes its use as “associated with specific views of life, death, and afterlife
NASA Astrophysics Data System (ADS)
Kunitsyn, V.; Andreeva, E. S.; Padokhin, A. M.; Vorontsov, A.; Frolov, V. L.; Komrakov, G.; Bernhardt, P. A.; Siefring, C. L.
2014-12-01
We present the results of the radiotomographic imaging and GNSS remote sensing of the artificial ionospheric disturbances obtained in the recent experiments on the modification of the midlatitude ionosphere by powerful HF radiowaves carried out at the Sura heating facility. The experiments were conducted using both O- and X- mode radiowaves, in daytime and nighttime conditions with various schemes of the radiation of the heating wave. Radio transmissions from the low- (Parus, e-POP on CASSIOPE) and high-orbital (GPS/GLONASS) navigational satellites received at the mobile network of receiving sites were used for the remote sensing of the heated area of the ionosphere. We study the variations in TEC caused by HF heating showing that the GNSS TEC spectra often contain frequency components corresponding to the modulation periods of the ERP of the heating wave. The manifestations of the heating-induced variations in TEC are most prominent in the area of magnetic zenith of the pumping wave. In this work we also present the radiotomographic reconstructions (including first time e-POP-SURA reconstructions) of the spatial structure of the disturbed area of the ionosphere corresponding to the directivity pattern of the heater as well as the spatial structure of the wave- like disturbances, which are possibly heating-induced AGWs, diverging from the heated area of the ionosphere. The spatial period of observed disturbances is 200-250 km and they are easily traced up to a distance of 700-800 km from the heated region, which is in good agreement with the modeling results.
Specialized properties of the triceps surae muscle-tendon unit in professional ballet dancers.
Moltubakk, M M; Magulas, M M; Villars, F O; Seynnes, O R; Bojsen-Møller, J
2018-05-03
This study compared professional ballet dancers (n = 10) to nonstretching controls (n = 10) with the purpose of comparing muscle and tendon morphology, mechanical, neural, and functional properties of the triceps surae and their role for ankle joint flexibility. Torque-angle and torque-velocity data were obtained during passive and active conditions by use of isokinetic dynamometry, while tissue morphology and mechanical properties were evaluated by ultrasonography. Dancers displayed longer gastrocnemius medialis fascicles (55 ± 5 vs 47 ± 6 mm) and a longer (207 ± 33 vs 167 ± 10 mm) and more compliant (230 ± 87 vs 364 ± 106 N/mm) Achilles tendon compared to controls. Greater passive ankle dorsiflexion range of motion (40 ± 7 vs 17 ± 9°) was seen in dancers, resulting from greater fascicle strain and greater elongation of the muscle. Peak electromyographic (EMG) activity recorded during passive stretching was lower in dancers, and at common joint angles, dancers displayed lower EMG amplitude and lower passive joint stiffness. No differences between groups were seen in maximal isometric plantar flexor torque, isokinetic peak torque, angle of peak torque, or work. In conclusion, the greater ankle joint flexibility of professional dancers seems attributed to multiple differences in morphological and mechanical properties of muscle and tendinous tissues, and to factors related to neural activation. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
3D curvature of muscle fascicles in triceps surae
Hamarneh, Ghassan; Wakeling, James M.
2014-01-01
Muscle fascicles curve along their length, with the curvatures occurring around regions of high intramuscular pressure, and are necessary for mechanical stability. Fascicles are typically considered to lie in fascicle planes that are the planes visualized during dissection or two-dimensional (2D) ultrasound scans. However, it has previously been predicted that fascicles must curve in three-dimensional (3D) and thus the fascicle planes may actually exist as 3D sheets. 3D fascicle curvatures have not been explored in human musculature. Furthermore, if the fascicles do not lie in 2D planes, then this has implications for architectural measures that are derived from 2D ultrasound scans. The purpose of this study was to quantify the 3D curvatures of the muscle fascicles and fascicle sheets within the triceps surae muscles and to test whether these curvatures varied among different contraction levels, muscle length, and regions within the muscle. Six male subjects were tested for three torque levels (0, 30, and 60% maximal voluntary contraction) and four ankle angles (−15, 0, 15, and 30° plantar flexion), and fascicles were imaged using 3D ultrasound techniques. The fascicle curvatures significantly increased at higher ankle torques and shorter muscle lengths. The fascicle sheet curvatures were of similar magnitude to the fascicle curvatures but did not vary between contractions. Fascicle curvatures were regionalized within each muscle with the curvature facing the deeper aponeuroses, and this indicates a greater intramuscular pressure in the deeper layers of muscles. Muscle architectural measures may be in error when using 2D images for complex geometries such as the soleus. PMID:25324510
Bilateral neuromuscular and force differences during a plyometric task.
Ball, Nick B; Scurr, Joanna C
2009-08-01
The purpose of this article is to compare the bilateral neuromuscular and force contribution during a plyometric bounce drop jump task and to assess the affects of nonsimultaneous foot placement. Sixteen male participants performed bounce drop jumps from a height of 0.4 m. Mean peak electromyography activity of the soleus, medial, and lateral gastrocnemius of both legs was recorded from each phase of the drop jump and normalized to a reference dynamic muscle action. Resultant ground reaction force, ground contact time, and duration of the drop jumps were recorded from each leg. Multivariate analysis of variance was used to compare bilateral electromyographic activity, resultant peak ground reaction force, and contact duration. Pearson's correlations (r) ascertained relationships between normalized electromyographic activity and contact time. Significant differences were shown between left and right triceps surae normalized electromyography during precontact and contact40ms (p < 0.01). No significant differences were present in the contactpost40ms phase (p > 0.01). Significant differences were found between normalized soleus electromyography and both gastrocnemii for both legs during precontact (p < 0.01). No significant differences were found for within-leg normalized electromyography for the contact40ms phases and contactpost40ms phase (p > 0.01). Weak relationships were found between normalized electromyographic activity and nonsimultaneous foot contact (r < 0.2). This study showed differences between left and right triceps surae in neuromuscular strategies engaged in the early stages of a drop jump task. Differences in contact time initiation were present; however, they are not significant enough to cause neuromuscular differences in the plantar flexor muscles.
Werkhausen, Amelie; Albracht, Kirsten; Cronin, Neil J; Meier, Rahel; Bojsen-Møller, Jens; Seynnes, Olivier R
2017-11-15
The compliance of elastic elements allows muscles to dissipate energy safely during eccentric contractions. This buffering function is well documented in animal models but our understanding of its mechanism in humans is confined to non-specific tasks, requiring a subsequent acceleration of the body. The present study aimed to examine the behaviour of the human triceps surae muscle-tendon unit (MTU) during a pure energy dissipation task, under two loading conditions. Thirty-nine subjects performed a single-leg landing task, with and without added mass. Ultrasound measurements were combined with three-dimensional kinematics and kinetics to determine instantaneous length changes of MTUs, muscle fascicles, Achilles tendon and combined elastic elements. Gastrocnemius and soleus MTUs lengthened during landing. After a small concentric action, fascicles contracted eccentrically during most of the task, whereas plantar flexor muscles were activated. Combined elastic elements lengthened until peak ankle moment and recoiled thereafter, whereas no recoil was observed for the Achilles tendon. Adding mass resulted in greater negative work and MTU lengthening, which were accompanied by a greater stretch of tendon and elastic elements and a greater recruitment of the soleus muscle, without any further fascicle strain. Hence, the buffering action of elastic elements delimits the maximal strain and lengthening velocity of active muscle fascicles and is commensurate with loading constraints. In the present task, energy dissipation was modulated via greater MTU excursion and more forceful eccentric contractions. The distinct strain pattern of the Achilles tendon supports the notion that different elastic elements may not systematically fulfil the same function. © 2017. Published by The Company of Biologists Ltd.
What Can We Learn About the Ionosphere Using the EISCAT Heating Facility?
2006-06-01
1970s to do both plasma physics and geophysical research. At present there are five operating facilities: HIPAS [1] and HAARP [2] in Alaska, Heating...1995: HAARP (Alaska) •2003: SPEAR (Svalbard) World overview 32 (8) 22 (16) 0.19 4-6 (2-3) 78.9 N 78.15 W SPEAR Spitsbergen Norway 150-280180-340...19.2 E 62.39 N 145.15W 65.0 N 147.0 W 18.3 N 66.8 W 40.18 N 104.73 E Geographic Coordinates SURA Russia Tromsø Norway HAARP Alaska USA HIPAS Alaska
The Navy’s Coupled Atmosphere-Ocean-Wave Prediction System
2011-04-15
is provided below. llMurly lurtir llcai Mux. N. M,*!. Heal I luv . .tn.l Wind Sura f»f \\. Hu. Alia il.t.iujn 2«OX) i n.H 1 1 1 T 1 1...DATE IDD-MM YYYY) 15-04-201 I 2. REPORT TYPE Conference Proceeding 3. DATES COVERED (From To) 4. TITLE AND SUBTITLE The Navy’s Coupled...Code 7Q3n A I Division, Code I Author, Code i .y "f^****^ Cv^py>v’V/v^ 1. Release of this paper is approved. 2. To the best knowledge of
Radiofrequency cordotomy for the relief of spasticity in decerebrate cats1
Soriano, Daniel; Herman, Richard
1971-01-01
The effectiveness of radiofrequency (RF) cordotomy of segmental motoneurone pools of the lumbosacral cord in reducing spasticity of decerebrate cats is evaluated. The need for a new form of therapy for clinical spasticity is based upon the limitations of contemporary methods, including surgical and pharmacological techniques. In man, spasticity of spinal origin may be treated effectively by intrathecal administration of hyperbaric phenol solutions. The advantages and disadvantages are described. Difficulty in controlling the lesion is emphasized. Tension and EMG-length curves of the spastic triceps surae muscle in acute and chronic animals show that RF lesions (fixed amperage and duration) of the segmental motoneurone pools reduces myotatic reflex activity in accordance with the number of segments cordotomized. Clinical examination including cinematography and electromyography complement the physiological interpretation. RF lesions of the internuncial pool induce spontaneous EMG discharges. This finding is related to similar observations of EMG discharges and alterations in muscle tone after asphyxiation of the spinal cord. Images PMID:5287593
Effects of footwear and strike type on running economy.
Perl, Daniel P; Daoud, Adam I; Lieberman, Daniel E
2012-07-01
This study tests if running economy differs in minimal shoes versus standard running shoes with cushioned elevated heels and arch supports and in forefoot versus rearfoot strike gaits. We measured the cost of transport (mL O(2)·kg(-1)·m(-1)) in subjects who habitually run in minimal shoes or barefoot while they were running at 3.0 m·s(-1) on a treadmill during forefoot and rearfoot striking while wearing minimal and standard shoes, controlling for shoe mass and stride frequency. Force and kinematic data were collected when subjects were shod and barefoot to quantify differences in knee flexion, arch strain, plantar flexor force production, and Achilles tendon-triceps surae strain. After controlling for stride frequency and shoe mass, runners were 2.41% more economical in the minimal-shoe condition when forefoot striking and 3.32% more economical in the minimal-shoe condition when rearfoot striking (P < 0.05). In contrast, forefoot and rearfoot striking did not differ significantly in cost for either minimal- or standard-shoe running. Arch strain was not measured in the shod condition but was significantly greater during forefoot than rearfoot striking when barefoot. Plantar flexor force output was significantly higher in forefoot than in rearfoot striking and in barefoot than in shod running. Achilles tendon-triceps surae strain and knee flexion were also lower in barefoot than in standard-shoe running. Minimally shod runners are modestly but significantly more economical than traditionally shod runners regardless of strike type, after controlling for shoe mass and stride frequency. The likely cause of this difference is more elastic energy storage and release in the lower extremity during minimal-shoe running.
Postactivation potentiation can counteract declines in force and power that occur after stretching.
Kümmel, J; Kramer, A; Cronin, N J; Gruber, M
2017-12-01
Stretching can decrease a muscle's maximal force, whereas short but intense muscle contractions can increase it. We hypothesized that when combined, postactivation potentiation induced by reactive jumps would counteract stretch-induced decrements in drop jump (DJ) performance. Moreover, we measured changes in muscle twitch forces and ankle joint stiffness (K A nkle ) to examine underlying mechanisms. Twenty subjects completed three DJs and 10 electrically evoked muscle twitches of the triceps surae subsequent to four different conditioning activities and control. The conditioning activities were 10 hops, 20s of static stretching of the triceps surae muscle, 20s of stretching followed by 10 hops, and vice versa. After 10 hops, twitch peak torque (TPT) was 20% and jump height 5% higher compared with control with no differences in K A nkle . After stretching, TPT and jump height were both 9% and K A nkle 6% lower. When hops and stretching were combined as conditioning activities, jump height was not different compared with control but significantly higher (11% and 8%) compared with stretching. TPTs were 16% higher compared with control when the hops were performed after stretching and 9% higher compared with the reverse order. K A nkle was significantly lower when stretching was performed after the hops (6%) compared with control, but no significant difference was observed when hops were performed after stretching. These results demonstrate that conditioning hops can counteract stretch-related declines in DJ performance. Furthermore, the differences in TPTs and K A nkle between combined conditioning protocols indicate that the order of conditioning tasks might play an important role at the muscle-tendon level. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Kay, Anthony D; Blazevich, Anthony J
2009-04-01
The effects of static stretch on muscle and tendon mechanical properties and muscle activation were studied in fifteen healthy human volunteers. Peak active and passive moment data were recorded during plantar flexion trials on an isokinetic dynamometer. Electromyography (EMG) monitoring of the triceps surae muscles, real-time motion analysis of the lower leg, and ultrasound imaging of the Achilles-medial gastrocnemius muscle-tendon junction were simultaneously conducted. Subjects performed three 60-s static stretches before being retested 2 min and 30 min poststretch. There were three main findings in the present study. First, peak concentric moment was significantly reduced after stretch; 60% of the deficit recovered 30 min poststretch. This was accompanied by, and correlated with (r = 0.81; P < 0.01) reductions in peak triceps surae EMG amplitude, which was fully recovered at 30 min poststretch. Second, Achilles tendon length was significantly shorter during the concentric contraction after stretch and at 30 min poststretch; however, no change in tendon stiffness was detected. Third, passive joint moment was significantly reduced after stretch, and this was accompanied by significant reductions in medial gastrocnemius passive muscle stiffness; both measures fully recovered by 30 min poststretch. These data indicate that the stretching protocol used in this study induced losses in concentric moment that were accompanied by, and related to, reductions in neuromuscular activity, but they were not associated with alterations in tendon stiffness or shorter muscle operating length. Reductions in passive moment were associated with reductions in muscle stiffness, whereas tendon mechanics were unaffected by the stretch. Importantly, the impact on mechanical properties and neuromuscular activity was minimal at 30 min poststretch.
Li, Jizhou; Zhou, Yongjin; Zheng, Yong-Ping; Li, Guanglin
2015-08-01
Muscle force output is an essential index in rehabilitation assessment or physical exams, and could provide considerable insights for various applications such as load monitoring and muscle assessment in sports science or rehabilitation therapy. Besides direct measurement of force output using a dynamometer, electromyography has earlier been used in several studies to quantify muscle force as an indirect means. However, its spatial resolution is easily compromised as a summation of the action potentials from neighboring motor units of electrode site. To explore an alternative method to indirectly estimate the muscle force output, and with better muscle specificity, we started with an investigation on the relationship between architecture dynamics and force output of triceps surae. The muscular architecture dynamics is captured in ultrasonography sequences and estimated using a previously reported motion estimation method. Then an indicator named as the dorsoventrally averaged motion profile (DAMP) is employed. The performance of force output is represented by an instantaneous version of the rate of force development (RFD), namely I-RFD. From experimental results on ten normal subjects, there were significant correlations between the I-RFD and DAMP for triceps surae, both normalized between 0 and 1, with the sum of squares error at 0.0516±0.0224, R-square at 0.7929±0.0931 and root mean squared error at 0.0159±0.0033. The statistical significance results were less than 0.01. The present study suggested that muscle architecture dynamics extracted from ultrasonography during contraction is well correlated to the I-RFD and it can be a promising option for indirect estimation of muscle force output. Copyright © 2015 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Tereshchenko, E. D.; Turyansky, V. A.; Khudukon, B. Z.; Yurik, R. Yu.; Frolov, V. L.
2018-01-01
We present the results of studying the characteristics of the artificial plasma structures excited in the ionospheric F2 region modified by high-power HF radio waves. The experiments were carried out at the Sura heating facility using satellite radio sounding of the ionosphere. The plasma density profile was reconstructed with the highest possible spatial resolution for today, about 4 km. In a direction close to the magnetic zenith of the pump wave, the following phenomena were observed: the formation of a cavity with a 15% lower plasma density at the altitudes of the F2 layer and below; the formation of an area with plasma density increased by 12% at altitudes greater than 400 km. With a long-term quasiperiodic impact of the pump wave on the ionosphere, wavy large-scale electron-density perturbations (the meridional scale λx ≈ 130 km and the vertical scale λz ≈ 440 km) are also formed above the Sura facility. These perturbations can be due to the plasma density modulation by an artificial acoustic-gravity wave with a period of 10.6 m, which was formed by the heat source inside a large-scale cavity with low plasma density; there is generation of the electron density irregularities for the electrons with ΔNe/Ne ≈ 3% in the form of layers having the sizes 10-12 km along and about 24 km across the geomagnetic field, which are found both below and above the F2-layer maximum. The mechanisms of the formation of these plasma structures are discussed.
Lorenzão, Caio José; Zimpel, Aline Veiga; Novakoski, Eduardo; da Silva, Aline Alves; Martinez-Pereira, Malcon Andrei
2016-03-01
In this study, the spinal nerves that constitute the lumbosacral plexus (LSP) were dissected in two species of South American wild canids (pampas fox-Pseudalopex gymnocercus, and crab-eating fox-Cerdocyon thous). The nerves origin and distribution in the pelvic limb were examined and compared with the LSP model of the dog described in the literature. The LSP was formed by whole ventral branches of L5 at L7 and S1, and a contribution of a one branch from S2, divided in three trunks. The trunk formed by union from L5-6 and S1 was divided into the cranial (cutaneus femoris lateralis nerve) medial (femoralis nerve) and lateral branches (obturatorius nerve). At the caudal part of the plexus, a thick branch, the ischiadicus plexus, was formed by contributions from L6-7 and S1-2. This root gives rise to the nerve branches which was disseminated to the pelvic limb (nerves gluteus cranial and gluteus caudal, cutaneus femoris caudalis and ischiadicus). The ischiadicus nerve was divided into fibularis communis and tibialis nerves. The tibialis nerve emits the cutaneus surae caudalis. The fibularis communis emits the cutaneus surae lateralis, fibularis superficialis and fibularis profundus. The pudendus nerve arises from S2 with contributions of one branch L7-S1 and one ramus of the cutaneus femoris lateralis. Still, one branch of S2 joins with S3 to form the rectales caudales nerve. These data provides an important anatomical knowledge of a two canid species of South American fauna, besides providing the effective surgical and clinical care of these animals. © 2016 Wiley Periodicals, Inc.
MacDonald, Christopher J; Lamont, Hugh S; Garner, John C
2012-02-01
Complex training (CT; alternating between heavy and lighter load resistance exercises with similar movement patterns within an exercise session) is a form of training that may potentially bring about a state of postactivation potentiation, resulting in increased dynamic power (Pmax) and rate of force development during the lighter load exercise. Such a method may be more effective than either modality, independently for developing strength. The purpose of this research was to compare the effects of resistance training (RT), plyometric training (PT), and CT on lower body strength and anthropometrics. Thirty recreationally trained college-aged men were trained using 1 of 3 methods: resistance, plyometric, or complex twice weekly for 6 weeks. The participants were tested pre, mid, and post to assess back squat strength, Romanian dead lift (RDL) strength, standing calf raise (SCR) strength, quadriceps girth, triceps surae girth, body mass, and body fat percentage. Diet was not controlled during this study. Statistical measures revealed a significant increase for squat strength (p = 0.000), RDL strength (p = 0.000), and SCR strength (p = 0.000) for all groups pre to post, with no differences between groups. There was also a main effect for time for girth measures of the quadriceps muscle group (p = 0.001), the triceps surae muscle group (p = 0.001), and body mass (p = 0.001; post hoc revealed no significant difference). There were main effects for time and group × time interactions for fat-free mass % (RT: p = 0.031; PT: p = 0.000). The results suggest that CT mirrors benefits seen with traditional RT or PT. Moreover, CT revealed no decrement in strength and anthropometric values and appears to be a viable training modality.
Effect of Real and Simulated Microgravity on Muscle Function
NASA Technical Reports Server (NTRS)
1997-01-01
In this session, Session JA3, the discussion focuses on the following topics: Changes in Calf Muscle Performance, Energy Metabolism, and Muscle Volume Caused by Long Term Stay on Space Station MIR; Vibrografic Signs of Autonomous Muscle Tone Studied in Long Term Space Missions; Reduction of Muscle Strength After Long Duration Space Flights is Associated Primarily with Changes in Neuromuscular Function; The Effects of a 115-Day Spaceflight on Neuromuscular Function in Crewman; Effects of 17-Day Spaceflight on Human Triceps Surae Electrically-Evoked Contractions; Effects of Muscle Unloading on EMG Spectral Parameters; and Myofiber Wound-Mediated FGF Release and Muscle Atrophy During Bedrest.
The Seven Sleepers: a folie à deux case originating from a religious-cultural belief.
Yazar, Menekse Sila; Erbek, Evrim; Eradamlar, Nezih; Alpkan, Latif
2011-11-01
Folie à deux is an uncommon psychiatric entity characterized by the transfer of delusional ideas and/or abnormal behavior from one person to another, or many others, who are in close contact with the primarily affected patient. In this paper we present a case of folie à deux, involving a married couple who suffered from a shared psychotic disorder with delusional interpretations of specific suras of the Koran. These mystical delusions were derived from the Anatolian legend of The Seven Sleepers. The case resulted in the death of the wife. This study illustrates the role of cultural and religious factors in folie à deux.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Belov, A. S., E-mail: alexis-belov@yandex.ru
2015-10-15
Results of numerical simulations of the near-Earth plasma perturbations induced by powerful HF radio waves from the SURA heating facility are presented. The simulations were performed using a modified version of the SAMI2 ionospheric model for the input parameters corresponding to the series of in-situ SURA–DEMETER experiments. The spatial structure and developmental dynamics of large-scale plasma temperature and density perturbations have been investigated. The characteristic formation and relaxation times of the induced large-scale plasma perturbations at the altitudes of the Earth’s outer ionosphere have been determined.
NASA Astrophysics Data System (ADS)
Frolov, V. L.; Komrakov, G. P.; Glukhov, Ya. V.; Andreeva, E. S.; Kunitsyn, V. E.; Kurbatov, G. A.
2016-07-01
We consider the experimental results obtained by studying the large-scale structure of the HF-disturbed ionospheric region. The experiments were performed using the SURA heating facility. The disturbed ionospheric region was sounded by signals radiated by GPS navigation satellite beacons as well as by signals of low-orbit satellites (radio tomography). The results of the experiments show that large-scale plasma density perturbations induced at altitudes higher than the F2 layer maximum can contribute significantly to the measured variations of the total electron density and can, with a certain arrangement of the reception points, be measured by the GPS sounding method.
NASA Technical Reports Server (NTRS)
Amtmann, E.; Kimura, T.; Oyama, J.; Doden, E.; Potulski, M.
1979-01-01
At the age of 30 days female Sprague-Dawley rats were placed on a 3.66 m radius centrifuge and subsequently exposed almost continuously for 810 days to either 2.76 or 4.15 G. An age-matched control group of rats was raised near the centrifuge facility at earth gravity. Three further control groups of rats were obtained from the animal colony and sacrificed at the age of 34, 72 and 102 days. A total of 16 variables were simultaneously factor analyzed by maximum-likelihood extraction routine and the factor loadings presented after-rotation to simple structure by a varimax rotation routine. The variables include the G-load, age, body mass, femoral length and cross-sectional area, inner and outer radii, density and strength at the mid-length of the femur, dry weight of gluteus medius, semimenbranosus and triceps surae muscles. Factor analyses on A) all controls, B) all controls and the 2.76 G group, and C) all controls and centrifuged animals, produced highly similar loading structures of three common factors which accounted for 74%, 68% and 68%. respectively, of the total variance. The 3 factors were interpreted as: 1. An age and size factor which stimulates the growth in length and diameter and increases the density and strength of the femur. This factor is positively correlated with G-load but is also active in the control animals living at earth gravity. 2. A growth inhibition factor which acts on body size, femoral length and on both the outer and inner radius at mid-length of the femur. This factor is intensified by centrifugation.
Field Work Proposal: PUBLIC OUTREACH EVENT FOR ACCELERATOR STEWARDSHIP TEST FACILITY PILOT PROGRAM
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hutton, Andrew; Areti, Hari
2015-03-05
Jefferson Lab’s outreach efforts towards the goals of Accelerator Stewardship Test Facility Pilot Program consist of the lab’s efforts in three venues. The first venue, at the end of March is to meet with the members of Virginia Tech Corporate Research Center (VTCRC) (http://www.vtcrc.com/tenant-directory/) in Blacksburg, Virginia. Of the nearly 160 members, we expect that many engineering companies (including mechanical, electrical, bio, software) will be present. To this group, we will describe the capabilities of Jefferson Lab’s accelerator infrastructure. The description will include not only the facilities but also the intellectual expertise. No funding is requested for this effort. Themore » second venue is to reach the industrial exhibitors at the 6th International Particle Accelerator Conference (IPAC’15). Jefferson Lab will host a booth at the conference to reach out to the >75 industrial exhibitors (https://www.jlab.org/conferences/ipac2015/SponsorsExhibitors.php) who represent a wide range of technologies. A number of these industries could benefit if they can access Jefferson Lab’s accelerator infrastructure. In addition to the booth, where written material will be available, we plan to arrange a session A/V presentation to the industry exhibitors. The booth will be hosted by Jefferson Lab’s Public Relations staff, assisted on a rotating basis by the lab’s scientists and engineers. The budget with IPAC’15 designations represents the request for funds for this effort. The third venue is the gathering of Southeastern Universities Research Association (SURA) university presidents. Here we plan to reach the research departments of the universities who can benefit by availing themselves to the infrastructure (material sciences, engineering, medical schools, material sciences, to name a few). Funding is requested to allow for attendance at the SURA Board Meeting. We are coordinating with DOE regarding these costs to raise the projected conference management cost ceiling in the Conference Management Tool.« less
A Distributed Laboratory for Event-Driven Coastal Prediction and Hazard Planning
NASA Astrophysics Data System (ADS)
Bogden, P.; Allen, G.; MacLaren, J.; Creager, G. J.; Flournoy, L.; Sheng, Y. P.; Graber, H.; Graves, S.; Conover, H.; Luettich, R.; Perrie, W.; Ramakrishnan, L.; Reed, D. A.; Wang, H. V.
2006-12-01
The 2005 Atlantic hurricane season was the most active in recorded history. Collectively, 2005 hurricanes caused more than 2,280 deaths and record damages of over 100 billion dollars. Of the storms that made landfall, Dennis, Emily, Katrina, Rita, and Wilma caused most of the destruction. Accurate predictions of storm-driven surge, wave height, and inundation can save lives and help keep recovery costs down, provided the information gets to emergency response managers in time. The information must be available well in advance of landfall so that responders can weigh the costs of unnecessary evacuation against the costs of inadequate preparation. The SURA Coastal Ocean Observing and Prediction (SCOOP) Program is a multi-institution collaboration implementing a modular, distributed service-oriented architecture for real time prediction and visualization of the impacts of extreme atmospheric events. The modular infrastructure enables real-time prediction of multi- scale, multi-model, dynamic, data-driven applications. SURA institutions are working together to create a virtual and distributed laboratory integrating coastal models, simulation data, and observations with computational resources and high speed networks. The loosely coupled architecture allows teams of computer and coastal scientists at multiple institutions to innovate complex system components that are interconnected with relatively stable interfaces. The operational system standardizes at the interface level to enable substantial innovation by complementary communities of coastal and computer scientists. This architectural philosophy solves a long-standing problem associated with the transition from research to operations. The SCOOP Program thereby implements a prototype laboratory consistent with the vision of a national, multi-agency initiative called the Integrated Ocean Observing System (IOOS). Several service- oriented components of the SCOOP enterprise architecture have already been designed and implemented, including data archive and transport services, metadata registry and retrieval (catalog), resource management, and portal interfaces. SCOOP partners are integrating these at the service level and implementing reconfigurable workflows for several kinds of user scenarios, and are working with resource providers to prototype new policies and technologies for on-demand computing.
Dimensions of the foot muscles in the lowland gorilla.
Oishi, Motoharu; Ogihara, Naomichi; Endo, Hideki; Komiya, Teruyuki; Kawada, Shin-Ichiro; Tomiyama, Tae; Sugiura, Yosuke; Ichihara, Nobutsune; Asari, Masao
2009-06-01
We dissected the hindlimb of a female western lowland gorilla and determined the muscle dimensions (mass, fascicle length, and physiological cross-sectional area: PCSA). Comparisons of the muscle parameters of the measured gorilla with corresponding reported human data demonstrated that the triceps surae muscles were larger and had more capacity to generate force than the other muscle groups in both species, but this tendency was more prominent in the human, probably as an adaptation to strong toe-off during bipedal walking. On the other hand, PCSAs of the extrinsic pedal digital flexors and digiti minimi muscles were larger in the western lowland gorilla, suggesting that the foot, particularly the fifth toe, has a relatively high grasping capability in the lowland gorilla.
2012-01-01
Background The use of botulinum toxin A (BT-A) for the treatment of lower limb spasticity is common in children with cerebral palsy (CP). Following the administration of BT-A, physical therapy plays a fundamental role in potentiating the functionality of the child. The balance deficit found in children with CP is mainly caused by muscle imbalance (spastic agonist and weak antagonist). Neuromuscular electrical stimulation (NMES) is a promising therapeutic modality for muscle strengthening in this population. The aim of the present study is to describe a protocol for a study aimed at analyzing the effects of NMES on dorsiflexors combined with physical therapy on static and functional balance in children with CP submitted to BT- A. Methods/Design Protocol for a prospective, randomized, controlled trial with a blinded evaluator. Eligible participants will be children with cerebral palsy (Levels I, II and III of the Gross Motor Function Classification System) between five and 12 years of age, with independent gait with or without a gait-assistance device. All participants will receive BT-A in the lower limbs (triceps surae). The children will then be randomly allocated for either treatment with motor physical therapy combined with NMES on the tibialis anterior or motor physical therapy alone. The participants will be evaluated on three occasions: 1) one week prior to the administration of BT-A; 2) one week after the administration of BT-A; and 3) four months after the administration of BT-A (end of intervention). Spasticity will be assessed by the Modified Ashworth Scale and Modified Tardieu Scale. Static balance will be assessed using the Medicapteurs Fusyo pressure platform and functional balance will be assessed using the Berg Balance Scale. Discussion The aim of this protocol study is to describe the methodology of a randomized, controlled, clinical trial comparing the effect of motor physical therapy combined with NMES on the tibialis anterior muscle or motor physical therapy alone on static and functional balance in children with CP submitted to BT-A in the lower limbs. This study describes the background, hypotheses, methodology of the procedures and measurement of the results. Trial registration RBR5qzs8h PMID:22591446
Sebille, A; Parlier, Y
1981-07-04
Electrophysiological exploration was carried out in 12 patients before and during administration of vincristine sulphate 1,4 mg/m2 body surface area. The patients had stage III or IV lymphoreticulosarcoma and received one injection of vincristine weekly for 6 weeks. Compared with pretreatment findings, (1) motor and sensory conduction velocity, as well as delay in triceps surae H reflex remained unchanged; (2) sensory nerve amplitude and density of distal muscle electromyographic recordings rapidly decreased; (3) the amplitude of distal tendinous reflexes rapidly diminished, whereas that of the H reflex remained stable. These results being similar to those observed in experimental acrylamide toxicity, where a "dying back" hemopathy has been demonstrated, it is suggested that the neuropathy induced by vincristine in man is of the same type.
Triceps surae muscle-tendon properties in older endurance- and sprint-trained athletes.
Stenroth, Lauri; Cronin, Neil J; Peltonen, Jussi; Korhonen, Marko T; Sipilä, Sarianna; Finni, Taija
2016-01-01
Previous studies have shown that aging is associated with alterations in muscle architecture and tendon properties (Morse CI, Thom JM, Birch KM, Narici MV. Acta Physiol Scand 183: 291-298, 2005; Narici MV, Maganaris CN, Reeves ND, Capodaglio P. J Appl Physiol 95: 2229-2234, 2003; Stenroth L, Peltonen J, Cronin NJ, Sipila S, Finni T. J Appl Physiol 113: 1537-1544, 2012). However, the possible influence of different types of regular exercise loading on muscle architecture and tendon properties in older adults is poorly understood. To address this, triceps surae muscle-tendon properties were examined in older male endurance (OE, n = 10, age = 74.0 ± 2.8 yr) and sprint runners (OS, n = 10, age = 74.4 ± 2.8 yr), with an average of 42 yr of regular training experience, and compared with age-matched [older control (OC), n = 33, age = 74.8 ± 3.6 yr] and young untrained controls (YC, n = 18, age = 23.7 ± 2.0 yr). Compared with YC, Achilles tendon cross-sectional area (CSA) was 22% (P = 0.022), 45% (P = 0.001), and 71% (P < 0.001) larger in OC, OE, and OS, respectively. Among older groups, OS had significantly larger tendon CSA compared with OC (P = 0.033). No significant between-group differences were observed in Achilles tendon stiffness. In older groups, Young's modulus was 31-44%, and maximal tendon stress 44-55% lower, than in YC (P ≤ 0.001). OE showed shorter soleus fascicle length than both OC (P < 0.05) and YC (P < 0.05). These data suggest that long-term running does not counteract the previously reported age-related increase in tendon CSA, but, instead, may have an additive effect. The greatest Achilles tendon CSA was observed in OS followed by OE and OC, suggesting that adaptation to running exercise is loading intensity dependent. Achilles tendon stiffness was maintained in older groups, even though all older groups displayed larger tendon CSA and lower tendon Young's modulus. Shorter soleus muscle fascicles in OE runners may be an adaptation to life-long endurance running. Copyright © 2016 the American Physiological Society.
Robertson, Benjamin D; Farris, Dominic J; Sawicki, Gregory S
2014-11-24
Development of robotic exoskeletons to assist/enhance human locomotor performance involves lengthy prototyping, testing, and analysis. This process is further convoluted by variability in limb/body morphology and preferred gait patterns between individuals. In an attempt to expedite this process, and establish a physiological basis for actuator prescription, we developed a simple, predictive model of human neuromechanical adaptation to a passive elastic exoskeleton applied at the ankle joint during a functional task. We modeled the human triceps surae-Achilles tendon muscle tendon unit (MTU) as a single Hill-type muscle, or contractile element (CE), and series tendon, or series elastic element (SEE). This modeled system was placed under gravitational load and underwent cyclic stimulation at a regular frequency (i.e. hopping) with and without exoskeleton (Exo) assistance. We explored the effect that both Exo stiffness (kExo) and muscle activation (Astim) had on combined MTU and Exo (MTU + Exo), MTU, and CE/SEE mechanics and energetics. Model accuracy was verified via qualitative and quantitative comparisons between modeled and prior experimental outcomes. We demonstrated that reduced Astim can be traded for increased kExo to maintain consistent MTU + Exo mechanics (i.e. average positive power (P⁺mech) output) from an unassisted condition (i.e. kExo = 0 kN · m⁻¹). For these regions of parameter space, our model predicted a reduction in MTU force, SEE energy cycling, and metabolic rate (Pmet), as well as constant CE P⁺mech output compared to unassisted conditions. This agreed with previous experimental observations, demonstrating our model's predictive ability. Model predictions also provided insight into mechanisms of metabolic cost minimization, and/or enhanced mechanical performance, and we concluded that both of these outcomes cannot be achieved simultaneously, and that one must come at the detriment of the other in a spring-assisted compliant MTU.
Body load in heel-strike running: the effect of a firm heel counter.
Jørgensen, U
1990-01-01
The effect of a firm heel counter in the shoe was studied in 11 athletes during submaximal heel-strike running on a treadmill under standardized conditions. The runners were tested in identical shoes with and without the distal 2 cm of the firm heel counter. Body load was expressed by absolute and relative VO2, surface EMG on the right leg, and g-force registration from an accelerometer below the right tibial tuberosity. The heel counter caused a 2.4% significant decrease in VO2, a reduction in musculoskeletal transients, and a decrease in the activity of the triceps surae and quadriceps muscles at heel strike. The changes found are expressions of kinematic adaptations in the body to increased or decreased load and provide functional evidence for the loading factor in the pathophysiology of overuse injuries.
Determining the VLF/ULF source height using phase measurements
NASA Astrophysics Data System (ADS)
Ryabov, A.; Kotik, D. S.
2012-12-01
Generation of ULF/VLF waves in the ionosphere using powerful RF facilities has been studied for the last 40 years, both theoretically and experimentally. During this time, it was proposed several mechanisms for explaining the experimental results: modulation of ionospheric currents based on thermal nonlinearity, ponderomotive mechanisms for generation both VLF and ULF signals, cubic nonlinearity, etc. According mentioned above mechanisms the VLF/ULF signal source could be located in the lower or upper ionosphere. The group velocity of signal propagation in the ionosphere is significantly smaller than speed of light. As a result the appreciable time delay of the received signals will occur at the earth surface. This time delay could be determine by measuring the phase difference between received and reference signals, which are GPS synchronized. The experiment on determining the time delay of ULF signal propagation from the ionospheric source was carried out at SURA facility in 2012 and the results are presented in this paper. The comparison with numerical simulation of the time delay using the adjusted IRI model and ionosonde data shows well agreement with the experimental observations. The work was supported by RFBR grant 11-02-00419-a and RF Ministry of education and science by state contract 16.518.11.7066.
NASA Technical Reports Server (NTRS)
Rietveld, M. T. (Editor)
1995-01-01
Papers from the conference are presented and cover the following topics: ion and electron beams; ionospheric modification; spacecraft interactions; chemical releases; and plasma waves. Auroras and plasma emissions are reported from electron beam injection experiments on the EXCEDE 3 rocket and APEX satellite respectively. The important parameters affecting the charging of spacecraft during the operation of electron guns is covered. The Active Magnetospheric Particle Acceleration Satellite (AMPAS) mission utilizing dual-payload tethered satellites and both up and downward directed electron beams is proposed to study the magnetosphere. Recent results and associated theories from the Sura, Arecibo and Troms ionospheric heating facitlites are presented. The effects of neutral gases on spacecraft charging are examined in a series of rocket flights. Many results from the Combined Release and Radiation Effects Satellite chemical release experiments are presented.
Improved Fab presentation on phage surface with the use of molecular chaperone coplasmid system.
Loh, Qiuting; Leong, Siew Wen; Tye, Gee Jun; Choong, Yee Siew; Lim, Theam Soon
2015-05-15
The low presentation efficiency of Fab (fragment antigen binding) fragments during phage display is largely due to the complexity of disulphide bond formation. This can result in the presentation of Fab fragments devoid of a light chain during phage display. Here we propose the use of a coplasmid system encoding several molecular chaperones (DsbA, DsbC, FkpA, and SurA) to improve Fab packaging. A comparison was done using the Fab fragment from IgG and IgD. We found that the use of the coplasmid during phage packaging was able to improve the presentation efficiency of the Fab fragment on phage surfaces. A modified version of panning using the coplasmid system was evaluated and was successful at enriching Fab binders. Therefore, the coplasmid system would be an attractive alternative for improved Fab presentation for phage display. Copyright © 2015 Elsevier Inc. All rights reserved.
Rensing, N; Westermann, A; Möller, D; von Piekartz, H
2015-12-01
Studies have shown changes in the technical and physical demands in modern handball. The game has increased considerably in speed, power and dynamics. Jump training has, therefore, become ever more important in the training of the athletes. These developments contribute to the fact that handball is now one of the most injury-prone types of sport, with the lower extremities being most frequently affected. Reactive jump training is not only used in training by now, but also increasingly in injury prevention. The aim of this study was to investigate the effectiveness of reactive jump training with handball players. 21 regional league handball players were randomly divided into an intervention group (n = 12) and a control group (n = 9). The intervention group completed a six-week reactive jump training programme while the control group went through a non-specific training programme. Jump height (squat and counter movement jump), isokinetic and isometric maximum power as well as muscle activity served as measuring parameters. A comparison of the intervention and control groups revealed that the reactive jump training led to significant improvements in jump height. The isometric and isokinetic maximum power measurements and the electromyographic activities of the triceps surae muscle demonstrated an improvement in the values within the intervention group. However, this improvement was not significant compared with the control group. Likewise both jumps correlated with the muscle activity of the soleus muscle as shown by electromyography. A moderate correlation was noticed between the isokinetic maximum power measurement and the electromyographic activity of the soleus and gastrocnemius medialis muscles. Furthermore, the correlations of the isometric and isokinetic maximum power meas-urements resulted in a strong correlation coefficient. This study revealed a significant increase in jump height after reactive jump training. There was no significant difference in power development between the two groups. However, we were able to demonstrate correlations which would make it seem reasonable and interesting to investigate the question more closely. An interesting field of research could be the question of the effectiveness of reactive jump training in the areas of rehabilitation and injury prevention. © Georg Thieme Verlag KG Stuttgart · New York.
Effects of Bed Rest on Conduction Velocity of the Triceps Surae Stretch Reflex and Postural Control
NASA Technical Reports Server (NTRS)
Reschke, M. F.; Wood, S. J.; Cerisano, J. M.; Kofman, I. S.; Fisher, E. A.; Esteves, J. T.; Taylor, L. C.; DeDios, Y. E.; Harm, D. L.
2011-01-01
Despite rigorous exercise and nutritional management during space missions, astronauts returning from microgravity exhibit neuromuscular deficits and a significant loss in muscle mass in the postural muscles of the lower leg. Similar changes in the postural muscles occur in subjects participating in long-duration bed rest studies. These adaptive muscle changes manifest as a reduction in reflex conduction velocity during head-down bed rest. Because the stretch reflex encompasses both the peripheral (muscle spindle and nerve axon) and central (spinal synapse) components involved in adaptation to calf muscle unloading, it may be used to provide feedback on the general condition of neuromuscular function, and might be used to evaluate the effectiveness of countermeasures aimed at preserving muscle mass and function during periods of unloading. Stretch reflexes were measured on 18 control subjects who spent 60 to 90 days in continuous 6 deg head-down bed rest. Using a motorized system capable of rotating the foot around the ankle joint (dorsiflexion) through an angle of 10 degrees at a peak velocity of about 250 deg/sec, a stretch reflex was recorded from the subject's left triceps surae muscle group. Using surface electromyography, about 300 reflex responses were obtained and ensemble-averaged on 3 separate days before bed rest, 3 to 4 times in bed, and 3 times after bed rest. The averaged responses for each test day were examined for reflex latency and conduction velocity (CV) across gender. Computerized posturography was also conducted on these same subjects before and after bed rest as part of the standard measures. Peak-to-peak sway was measured during Sensory Organization Tests (SOTs) to evaluate changes in the ability to effectively use or suppress visual, vestibular, and proprioceptive information for postural control. Although no gender differences were found, a significant increase in reflex latency and a significant decrease in CV were observed during the bed rest period, with a return to baseline 3 to 5 days after bed rest, depending on the duration of bed rest. In addition, a relationship between CV and loss of muscle strength in the lower leg was observed post bed rest for most subjects. Immediately post-bed rest, most subjects showed decreased performance on SOTs, with the greater decrements on sway-referenced support and head movement conditions. Post-bed rest decrements were less than typically observed following spaceflight. Decrements in postural control and the stretch reflex can be primarily attributed to the unloading mechanisms this ground-based analog provides. The stretch reflex is a concise test measurement that can be obtained during the head-down phase of bed rest, as it does not interfere with the bed rest paradigm. This makes it an ideal tool that can detect, early on, whether a countermeasure is successful in preserving muscle function.
Towards a Switched-Capacitor Based Stimulator for Efficient Deep-Brain Stimulation
Vidal, Jose; Ghovanloo, Maysam
2013-01-01
We have developed a novel 4-channel prototype stimulation circuit for implantable neurological stimulators (INS). This Switched-Capacitor based Stimulator (SCS) aims to utilize charge storage and charge injection techniques to take advantage of both the efficiency of conventional voltage-controlled stimulators (VCS) and the safety and controllability of current-controlled stimulators (CCS). The discrete SCS prototype offers fine control over stimulation parameters such as voltage, current, pulse width, frequency, and active electrode channel via a LabVIEW graphical user interface (GUI) when connected to a PC through USB. Furthermore, the prototype utilizes a floating current sensor to provide charge-balanced biphasic stimulation and ensure safety. The stimulator was analyzed using an electrode-electrolyte interface (EEI) model as well as with a pair of pacing electrodes in saline. The primary motivation of this research is to test the feasibility and functionality of a safe, effective, and power-efficient switched-capacitor based stimulator for use in Deep Brain Stimulation. PMID:21095987
Shaikh, Muhammad Faraz; Salcic, Zoran; Wang, Kevin I-Kai; Hu, Aiguo Patrick
2018-03-10
Electrical stimulators are often prescribed to correct foot drop walking. However, commercial foot drop stimulators trigger inappropriately under certain non-gait scenarios. Past researches addressed this limitation by defining stimulation control based on automaton of a gait cycle executed by foot drop of affected limb/foot only. Since gait is a collaborative activity of both feet, this research highlights the role of normal foot for robust gait detection and stimulation triggering. A novel bipedal gait model is proposed where gait cycle is realized as an automaton based on concurrent gait sub-phases (states) from each foot. The input for state transition is fused information from feet-worn pressure and inertial sensors. Thereafter, a bipedal gait model-based stimulation control algorithm is developed. As a feasibility study, bipedal gait model and stimulation control are evaluated in real-time simulation manner on normal and simulated foot drop gait measurements from 16 able-bodied participants with three speed variations, under inappropriate triggering scenarios and with foot drop rehabilitation exercises. Also, the stimulation control employed in commercial foot drop stimulators and single foot gait-based foot drop stimulators are compared alongside. Gait detection accuracy (98.9%) and precise triggering under all investigations prove bipedal gait model reliability. This infers that gait detection leveraging bipedal periodicity is a promising strategy to rectify prevalent stimulation triggering deficiencies in commercial foot drop stimulators. Graphical abstract Bipedal information-based gait recognition and stimulation triggering.
A microprocessor-based multichannel subsensory stochastic resonance electrical stimulator.
Chang, Gwo-Ching
2013-01-01
Stochastic resonance electrical stimulation is a novel intervention which provides potential benefits for improving postural control ability in the elderly, those with diabetic neuropathy, and stroke patients. In this paper, a microprocessor-based subsensory white noise electrical stimulator for the applications of stochastic resonance stimulation is developed. The proposed stimulator provides four independent programmable stimulation channels with constant-current output, possesses linear voltage-to-current relationship, and has two types of stimulation modes, pulse amplitude and width modulation.
Liew, Bernard X W; Morris, Susan; Keogh, Justin W L; Appleby, Brendyn; Netto, Kevin
2016-10-22
In recent years, athletes have ventured into ultra-endurance and adventure racing events, which tests their ability to race, navigate, and survive. These events often require race participants to carry some form of load, to bear equipment for navigation and survival purposes. Previous studies have reported specific alterations in biomechanics when running with load which potentially influence running performance and injury risk. We hypothesize that a biomechanically informed neuromuscular training program would optimize running mechanics during load carriage to a greater extent than a generic strength training program. This will be a two group, parallel randomized controlled trial design, with single assessor blinding. Thirty healthy runners will be recruited to participate in a six weeks neuromuscular training program. Participants will be randomized into either a generic training group, or a biomechanically informed training group. Primary outcomes include self-determined running velocity with a 20 % body weight load, jump power, hopping leg stiffness, knee extensor and triceps-surae strength. Secondary outcomes include running kinetics and kinematics. Assessments will occur at baseline and post-training. To our knowledge, no training programs are available that specifically targets a runner's ability to carry load while running. This will provide sport scientists and coaches with a foundation to base their exercise prescription on. ANZCTR ( ACTRN12616000023459 ) (14 Jan 2016).
2013-01-01
Background Tachykinins can have pro-inflammatory as well as healing effects during tissue reorganization and inflammation. Recent studies report an up-regulation in the expression of the substance P (SP)-preferred receptor, the neurokinin-1 receptor, in marked muscle inflammation (myositis). There is, however, only very little information on the expression patterns and levels of tachykinins in this situation. Methods The tachykinin system was analyzed using a rabbit experimental model of muscle overuse, whereby unilateral muscle exercise in combination with electrical stimulation led to muscle derangement and myositis in the triceps surae muscle (experimental length 1–6 weeks). Evaluations were made for both parts of the muscle (soleus and gastrocnemius muscles) in experimental and non-experimental (contralateral) sides. Morphologic evaluation, immunohistochemistry, in situ hybridization and enzyme immunoassay (EIA) analyses were applied. Results Myositis and muscle derangement occurred focally not only in the experimental side but also in the non-experimental side. In the inflammatory areas (focal myositis areas), there were frequent nerve fibers showing tachykinin-like immunoreactivity and which were parts of nerve fascicles and which were freely dispersed in the tissue. Cells in the inflammatory infiltrates showed tachykinin-like immunoreactivity and tachykinin mRNA expression. Specific immunoreactivity and mRNA expression were noted in blood vessel walls of both sides, especially in focally affected areas. With increasing experimental length, we observed an increase in the degree of immunoreactivity in the vessel walls. The EIA analyses showed that the concentration of tachykinin in the tissue on both sides increased in a time-dependent manner. There was a statistical correlation in the concentration of tachykinin and the level of tachykinin immunoreactivity in the blood vessel walls between experimental and non-experimental sides. Conclusions The observations show an up-regulation of the tachykinin system bilaterally during muscle derangement/myositis in response to pronounced unilateral muscle overuse. This up-regulation occurred in inflammatory areas and was related not only to increased tachykinin innervation but also to tachykinin expression in blood vessel walls and inflammatory cells. Importantly, the tachykinin system appears to be an important factor not only ipsilaterally but also contralaterally in these processes. PMID:23587295
Song, Yafeng; Stål, Per S; Yu, Ji-Guo; Forsgren, Sture
2013-04-12
Tachykinins can have pro-inflammatory as well as healing effects during tissue reorganization and inflammation. Recent studies report an up-regulation in the expression of the substance P (SP)-preferred receptor, the neurokinin-1 receptor, in marked muscle inflammation (myositis). There is, however, only very little information on the expression patterns and levels of tachykinins in this situation. The tachykinin system was analyzed using a rabbit experimental model of muscle overuse, whereby unilateral muscle exercise in combination with electrical stimulation led to muscle derangement and myositis in the triceps surae muscle (experimental length 1-6 weeks). Evaluations were made for both parts of the muscle (soleus and gastrocnemius muscles) in experimental and non-experimental (contralateral) sides. Morphologic evaluation, immunohistochemistry, in situ hybridization and enzyme immunoassay (EIA) analyses were applied. Myositis and muscle derangement occurred focally not only in the experimental side but also in the non-experimental side. In the inflammatory areas (focal myositis areas), there were frequent nerve fibers showing tachykinin-like immunoreactivity and which were parts of nerve fascicles and which were freely dispersed in the tissue. Cells in the inflammatory infiltrates showed tachykinin-like immunoreactivity and tachykinin mRNA expression. Specific immunoreactivity and mRNA expression were noted in blood vessel walls of both sides, especially in focally affected areas. With increasing experimental length, we observed an increase in the degree of immunoreactivity in the vessel walls. The EIA analyses showed that the concentration of tachykinin in the tissue on both sides increased in a time-dependent manner. There was a statistical correlation in the concentration of tachykinin and the level of tachykinin immunoreactivity in the blood vessel walls between experimental and non-experimental sides. The observations show an up-regulation of the tachykinin system bilaterally during muscle derangement/myositis in response to pronounced unilateral muscle overuse. This up-regulation occurred in inflammatory areas and was related not only to increased tachykinin innervation but also to tachykinin expression in blood vessel walls and inflammatory cells. Importantly, the tachykinin system appears to be an important factor not only ipsilaterally but also contralaterally in these processes.
Effects of knee and ankle muscle fatigue on postural control in the unipedal stance.
Bizid, Riadh; Margnes, Eric; François, Yrieix; Jully, Jean Louis; Gonzalez, Gerard; Dupui, Philippe; Paillard, Thierry
2009-06-01
The aim of this study was to compare the effects of acute muscle fatigue of the ankle and knee musculature on postural control by immediate measures after performing fatiguing tasks (POST condition). One group of subjects (n = 8) performed a fatiguing task by voluntary contractions of the triceps surae (group TRI) and the other (n = 9) performed a fatiguing task by voluntary contractions of the quadriceps femoris (group QUA). Each muscle group was exercised until the loss of maximal voluntary contraction torque reached 50% (isokinetic dynamometer). Posture was assessed by measuring the centre of foot pressure (COP) with a force platform during a test of unipedal quiet standing posture with eyes closed. Initially (in PRE condition), the mean COP velocity was not significantly different between group TRI and group QUA. In POST condition, the mean COP velocity increased more in group QUA than in group TRI. The postural control was more impaired by knee muscle fatigue than by ankle muscle fatigue.
Periplasmic quality control in biogenesis of outer membrane proteins.
Lyu, Zhi Xin; Zhao, Xin Sheng
2015-04-01
The β-barrel outer membrane proteins (OMPs) are integral membrane proteins that reside in the outer membrane of Gram-negative bacteria and perform a diverse range of biological functions. Synthesized in the cytoplasm, OMPs must be transported across the inner membrane and through the periplasmic space before they are assembled in the outer membrane. In Escherichia coli, Skp, SurA and DegP are the most prominent factors identified to guide OMPs across the periplasm and to play the role of quality control. Although extensive genetic and biochemical analyses have revealed many basic functions of these periplasmic proteins, the mechanism of their collaboration in assisting the folding and insertion of OMPs is much less understood. Recently, biophysical approaches have shed light on the identification of the intricate network. In the present review, we summarize recent advances in the characterization of these key factors, with a special emphasis on the multifunctional protein DegP. In addition, we present our proposed model on the periplasmic quality control in biogenesis of OMPs.
Selective activation of human soleus and medial gastrocnemius muscles during walking in water.
Miyoshi, T; Satoh, T; Nakazawa, K; Komeda, T; Yano, H
2000-07-01
During walking in water (WW) the vertical component of ground reaction forces decreases, while the greater propulsive force is required to move forward against the greater resistance of water. In such reduced gravity environment, Hutchison et al. (1989) have demonstrated that the relative activation of rat medial gastrocnemius (MGAS) increased compared to that of the soleus (SOL) during swimming, suggesting different effects of peripheral information on motoneuron excitability of these muscles. It is conceivable that both buoyancy and resistance of water have different effects on the activation patterns of triceps surae muscles during WW, since the reduced weight in water might decrease the peripheral inflow relating load information while greater volitional command might be needed to propel a body forward against the water resistance. The present study was designed to assess each peripheral inflow and efferent input by adjusting the load and walking speed voluntarily during WW. The aim of this study is to investigate the dissociative activation pattern between the SOL and the MGAS during WW.
NASA Astrophysics Data System (ADS)
Rietveld, M. T.
1995-07-01
Papers from the conference are presented and cover the following topics: ion and electron beams; ionospheric modification; spacecraft interactions; chemical releases; and plasma waves. Auroras and plasma emissions are reported from electron beam injection experiments on the EXCEDE 3 rocket and APEX satellite respectively. The important parameters affecting the charging of spacecraft during the operation of electron guns is covered. The Active Magnetospheric Particle Acceleration Satellite (AMPAS) mission utilizing dual-payload tethered satellites and both up and downward directed electron beams is proposed to study the magnetosphere. Recent results and associated theories from the Sura, Arecibo and Troms ionospheric heating facitlites are presented. The effects of neutral gases on spacecraft charging are examined in a series of rocket flights. Many results from the Combined Release and Radiation Effects Satellite chemical release experiments are presented. For individual titles, see A95-83500 through A95-83535.
Effects of Functional Training and Calf Stretching on Risk of Falls in Older People: A Pilot Study.
do Rosario, Jailton Thulher; da Fonseca Martins, Natalia Santos; Peixinho, Carolina Carneiro; Oliveira, Liliam Fernandes
2017-04-01
This study aimed to determine the effects of a functional training and ankle stretching program in triceps surae torque, passive stiffness index, and in the risk for fall indicators in older adults. Twenty women (73.4 ± 7.3 years) were allocated into an intervention or control group. The 12-week intervention consisted of functional training and calf stretching exercises performed twice a week. Measurements of peak passive and active torque, passive stiffness, maximum dorsiflexion angle, and indexes of risk for falls (Timed Up and Go, functional reach test, QuickScreen-test) were collected. There were no significant differences for all variables, except the maximum dorsiflexion angle, which increased in the intervention group from 33.78 ± 8.57° to 38.89 ± 7.52°. The exercise program was not sufficient to enhance performance on functional tests and decrease the risk for falls in older adults. The significant increase in the maximum dorsiflexion indicates a positive impact of stretching exercises.
Rougier, Patrice; Burdet, Cyril; Genthon, Nicolas
2006-10-01
To assess whether prior stretching of a muscle can induce improved postural control, 15 healthy adults stood still upright with their eyes closed before and after a series of bilateral stretches of the triceps surae muscles. The analysis focused on the center of pressure (CP) and the vertical projection of the center of gravity (CGv) trajectories and their difference (CP - CGv). The prolonged stretching induced a forward shift of the mean position of the CGv. The frequency analysis showed a constancy of the amplitudes of both basic movements whereas an increased mean power frequency was seen for the CP - CGv movements. A fractional Brownian motion modeling of the trajectories indicates shortest time intervals and lower covered distances by the CGv before a change in its control occurs along the antero-posterior axis. This reorganization is thought to be a result of improved body movement detection, which allows postural control over the longest time intervals to be triggered more rapidly.
Wang, Zhi-Yong; Wang, Jian-Wei; Qin, Li-Hua; Zhang, Wei-Guang; Zhang, Pei-Xun; Jiang, Bao-Guo
2018-06-01
To investigate the efficacy of chitin biological absorbable catheters in a rat model of autologous nerve transplantation. A segment of sciatic nerve was removed to produce a sciatic nerve defect, and the sural nerve was cut from the ipsilateral leg and used as a graft to bridge the defect, with or without use of a chitin biological absorbable catheter surrounding the graft. The number and morphology of regenerating myelinated fibers, nerve conduction velocity, nerve function index, triceps surae muscle morphology, and sensory function were evaluated at 9 and 12 months after surgery. All of the above parameters were improved in rats in which the nerve graft was bridged with chitin biological absorbable catheters compared with rats without catheters. The results of this study indicate that use of chitin biological absorbable catheters to surround sural nerve grafts bridging sciatic nerve defects promotes recovery of structural, motor, and sensory function and improves muscle fiber morphology. © 2018 John Wiley & Sons Ltd.
Sustainable Agro-Industrial Ecology Concept of the Madura Island
NASA Astrophysics Data System (ADS)
Widjaya, Joyce Martha; Tanuwidjaja, Gunawan
2017-07-01
Madura as one small island in East Java Province, Indonesia faced many challenges due to limited transportation connectivity, limited water resources and karst geology. Due to this reasons, the Government of Indonesia proposed a strategic plan to improve the development of the island to Surabaya, the largest port for the Eastern of Indonesia. It was started with building the Surabaya - Madura (SuraMadu) Bridge with 5.7 km length in 2003. The bridge was finally completed in 2009, improving the traffic flow into the island and development of Madura Island. Unfortunately, the strategy would not be comprehensive without strategic development of the Madura Island, especially in Bangkalan District (Kabupaten Bangkalan). The Central Government has proposed a Green Industry with zero waste and clean energy concept. This industry and port would process the agriculture products from Madura for the export and Eastern part of Indonesia market. Therefore, an industrial ecology concept was needed to achieve the sustainable green industry for Eastern of Indonesia.
Optimized temporal pattern of brain stimulation designed by computational evolution
Brocker, David T.; Swan, Brandon D.; So, Rosa Q.; Turner, Dennis A.; Gross, Robert E.; Grill, Warren M.
2017-01-01
Brain stimulation is a promising therapy for several neurological disorders, including Parkinson’s disease. Stimulation parameters are selected empirically and are limited to the frequency and intensity of stimulation. We used the temporal pattern of stimulation as a novel parameter of deep brain stimulation to ameliorate symptoms in a parkinsonian animal model and in humans with Parkinson’s disease. We used model-based computational evolution to optimize the stimulation pattern. The optimized pattern produced symptom relief comparable to that from standard high-frequency stimulation (a constant rate of 130 or 185 Hz) and outperformed frequency-matched standard stimulation in the parkinsonian rat and in patients. Both optimized and standard stimulation suppressed abnormal oscillatory activity in the basal ganglia of rats and humans. The results illustrate the utility of model-based computational evolution to design temporal pattern of stimulation to increase the efficiency of brain stimulation in Parkinson’s disease, thereby requiring substantially less energy than traditional brain stimulation. PMID:28053151
Comparison of Gait Aspects According to FES Stimulation Position Applied to Stroke Patients
Mun, Byeong-mu; Kim, Tae-ho; Lee, Jin-hwan; Lim, Jin-youg; Seo, Dong-kwon; Lee, Dong-jin
2014-01-01
[Purpose] This study sought to identify the gait aspects according to the FES stimulation position in stroke patients during gait training. [Subjects and Methods] To perform gait analysis, ten stroke patients were grouped based on 4 types of gait conditions: gait without FES stimulation (non-FES), gait with FES stimulation on the tibialis anterior (Ta), gait with FES stimulation on the tibialis anterior and quadriceps (TaQ), and gait with FES stimulation on the tibialis anterior and gluteus medius (TaGm). [Results] Based on repeated measures analysis of variance of measurements of gait aspects comprised of gait speed, gait cycle, and step length according to the FES stimulation position, the FES stimulation significantly affected gait aspects. [Conclusion] In conclusion, stimulating the tibialis anterior and quadriceps and stimulating the tibialis anterior and gluteus medius are much more effective than stimulating only the tibialis anterior during gait training in stroke patients using FES. PMID:24764634
A pilot study of planar coil based magnetic stimulation using acute hippocampal slice in mice.
Park, H J; Kang, H K; Wang, M; Jo, J; Chung, E; Kim, S
2017-07-01
Micromagnetic stimulation using small-sized implantable coils has recently been studied. The main advantage of this method is that it can provide sustainable stimulation performance even if a fibrotic encapsulation layer is formed around the implanted coil by inflammation response, because indirectly induced currents are used to induce neural responses. In previous research, we optimized the geometrical and control parameters used in implantable magnetic stimulation. Based on those results, we fabricated the planar coil and studied the LTP effect in the hippocampal slice by two different magnetic stimulation protocols using the quadripulse stimulation (QPS) pattern. We found that direct magnetic stimulation (DMS) induced insignificant LTP effect and priming magnetic stimulation (PMS) occluded LTP effect after tetanic stimulation, when QPS patterned magnetic stimulation with 1 A current pulse was applied to the planar coil.
New stimulation pattern design to improve P300-based matrix speller performance at high flash rate
NASA Astrophysics Data System (ADS)
Polprasert, Chantri; Kukieattikool, Pratana; Demeechai, Tanee; Ritcey, James A.; Siwamogsatham, Siwaruk
2013-06-01
Objective. We propose a new stimulation pattern design for the P300-based matrix speller aimed at increasing the minimum target-to-target interval (TTI). Approach. Inspired by the simplicity and strong performance of the conventional row-column (RC) stimulation, the proposed stimulation is obtained by modifying the RC stimulation through alternating row and column flashes which are selected based on the proposed design rules. The second flash of the double-flash components is then delayed for a number of flashing instants to increase the minimum TTI. The trade-off inherited in this approach is the reduced randomness within the stimulation pattern. Main results. We test the proposed stimulation pattern and compare its performance in terms of selection accuracy, raw and practical bit rates with the conventional RC flashing paradigm over several flash rates. By increasing the minimum TTI within the stimulation sequence, the proposed stimulation has more event-related potentials that can be identified compared to that of the conventional RC stimulations, as the flash rate increases. This leads to significant performance improvement in terms of the letter selection accuracy, the raw and practical bit rates over the conventional RC stimulation. Significance. These studies demonstrate that significant performance improvement over the RC stimulation is obtained without additional testing or training samples to compensate for low P300 amplitude at high flash rate. We show that our proposed stimulation is more robust to reduced signal strength due to the increased flash rate than the RC stimulation.
Plantar fascia anatomy and its relationship with Achilles tendon and paratenon
Stecco, Carla; Corradin, Marco; Macchi, Veronica; Morra, Aldo; Porzionato, Andrea; Biz, Carlo; De Caro, Raffaele
2013-01-01
Although the plantar fascia (PF) has been studied quite well from a biomechanical viewpoint, its microscopic properties have been overlooked: nothing is known about its content of elastic fibers, the features of the extracellular matrix or the extent of innervation. From a functional and clinical standpoint, the PF is often correlated with the triceps surae muscle, but the anatomical grounds for this link are not clear. The aim of this work was to focus on the PF macroscopic and microscopic properties and study how Achilles tendon diseases might affect it. Twelve feet from unembalmed human cadavers were dissected to isolate the PF. Specimens from each PF were tested with various histological and immunohistochemical stains. In a second stage, 52 magnetic resonance images (MRI) obtained from patients complaining of aspecific ankle or foot pain were analyzed, dividing the cases into two groups based on the presence or absence of signs of degeneration and/or inflammation of the Achilles tendon. The thickness of PF and paratenon was assessed in the two groups and statistical analyses were conducted. The PF is a tissue firmly joined to plantar muscles and skin. Analyzing its possible connections to the sural structures showed that this fascia is more closely connected to the paratenon of Achilles tendon than to the Achilles tendon, through the periosteum of the heel. The PF extended medially and laterally, continuing into the deep fasciae enveloping the abductor hallucis and abductor digiti minimi muscles, respectively. The PF was rich in hyaluronan, probably produced by fibroblastic-like cells described as ‘fasciacytes’. Nerve endings and Pacini and Ruffini corpuscles were present, particularly in the medial and lateral portions, and on the surface of the muscles, suggesting a role for the PF in the proprioception of foot. In the radiological study, 27 of the 52 MRI showed signs of Achilles tendon inflammation and/or degeneration, and the PF was 3.43 ± 0.48 mm thick (99%CI and SD = 0.95), as opposed to 2.09 ± 0.24 mm (99%CI, SD = 0.47) in the patients in which the MRI revealed no Achilles tendon diseases; this difference in thickness of 1.29 ± 0.57 mm (99%CI) was statistically significant (P < 0.001). In the group of 27/52 patients with tendinopathies, the PF was more than 4.5 mm thick in 5, i.e. they exceeded the threshold for a diagnosis of plantar fasciitis. None of the other 25/52 paitents had a PF more than 4 mm thick. There was a statistically significant correlation between the thicknesses of the PF and the paratenon. These findings suggest that the plantar fascia has a role not only in supporting the longitudinal arch of the foot, but also in its proprioception and peripheral motor coordination. Its relationship with the paratenon of the Achilles tendon is consistent with the idea of triceps surae structures being involved in the PF pathology, so their rehabilitation can be considered appropriate. Finally, the high concentration of hyaluronan in the PF points to the feasibility of using hyaluronan injections in the fascia to treat plantar fasciitis. PMID:24028383
Qu, Hongen; Xie, Yongji; Liu, Xiaoxuan; He, Xin; Hao, Manzhao; Bao, Yong; Xie, Qing; Lan, Ning
2016-01-01
Neuromuscular electrical stimulation (NMES) is a promising assistive technology for stroke rehabilitation. Here we present the design and development of a multimuscle stimulation system as an emerging therapy for people with paretic stroke. A network-based multichannel NMES system was integrated based on dual bus architecture of communication and an H-bridge current regulator with a power booster. The structure of the system was a body area network embedded with multiple stimulators and a communication protocol of controlled area network to transmit muscle stimulation parameter information to individual stimulators. A graphical user interface was designed to allow clinicians to specify temporal patterns and muscle stimulation parameters. We completed and tested a prototype of the hardware and communication software modules of the multichannel NMES system. The prototype system was first verified in nondisabled subjects for safety, and then tested in subjects with stroke for feasibility with assisting multijoint movements. Results showed that synergistic stimulation of multiple muscles in subjects with stroke improved performance of multijoint movements with more natural velocity profiles at elbow and shoulder and reduced acromion excursion due to compensatory trunk rotation. The network-based NMES system may provide an innovative solution that allows more physiological activation of multiple muscles in multijoint task training for patients with stroke.
Ti, Lianping; Richardson, Lindsey; DeBeck, Kora; Nguyen, Paul; Montaner, Julio; Wood, Evan; Kerr, Thomas
2014-01-01
Background Despite the growing prevalence of illicit stimulant drug use internationally, and the widespread involvement of people who inject drugs (IDU) within street-based drug markets, little is known about the impact of different types of street-based income generation activities on the cessation of stimulant use among IDU. Methods Data were derived from an open prospective cohort of IDU in Vancouver, Canada. We used Kaplan-Meier methods and Cox proportional hazards regression to examine the effect of different types of street-based income generation activities (e.g., sex work, drug dealing, and scavenging) on time to cessation of stimulant use. Results Between December, 2005 and November, 2012, 887 IDU who use stimulant drugs (cocaine, crack cocaine, or crystal methamphetamine) were prospectively followed-up for a median duration of 47 months. In Kaplan-Meier analyses, compared to those who did not engage in street-based income generation activities, participants who reported sex work, drug dealing, scavenging, or more than one of these activities were significantly less likely to report stimulant drug use cessation (all p<0.001). When considered as time-updated variables and adjusted for potential confounders in a multivariable model, each type of street-based income generation activity remained significantly associated with a slower time to stimulant drug cessation (all p<0.005). Conclusions Our findings highlight the urgent need for strategies to address stimulant dependence, including novel pharmacotherapies. Also important, structural interventions, such as low-threshold employment opportunities, availability of supportive housing, legal reforms regarding drug use, and evidence-based approaches that reduce harm among IDU are urgently required. PMID:24909853
Ti, Lianping; Richardson, Lindsey; DeBeck, Kora; Nguyen, Paul; Montaner, Julio; Wood, Evan; Kerr, Thomas
2014-08-01
Despite the growing prevalence of illicit stimulant drug use internationally, and the widespread involvement of people who inject drugs (IDU) within street-based drug markets, little is known about the impact of different types of street-based income generation activities on the cessation of stimulant use among IDU. Data were derived from an open prospective cohort of IDU in Vancouver, Canada. We used Kaplan-Meier methods and Cox proportional hazards regression to examine the effect of different types of street-based income generation activities (e.g., sex work, drug dealing, and scavenging) on time to cessation of stimulant use. Between December, 2005 and November, 2012, 887 IDU who use stimulant drugs (cocaine, crack cocaine, or crystal methamphetamine) were prospectively followed-up for a median duration of 47 months. In Kaplan-Meier analyses, compared to those who did not engage in street-based income generation activities, participants who reported sex work, drug dealing, scavenging, or more than one of these activities were significantly less likely to report stimulant drug use cessation (all p<0.001). When considered as time-updated variables and adjusted for potential confounders in a multivariable model, each type of street-based income generation activity remained significantly associated with a slower time to stimulant drug cessation (all p<0.005). Our findings highlight the urgent need for strategies to address stimulant dependence, including novel pharmacotherapies. Also important, structural interventions, such as low-threshold employment opportunities, availability of supportive housing, legal reforms regarding drug use, and evidence-based approaches that reduce harm among IDU are urgently required. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Transient stimulation expands superior antitumor T cells for adoptive therapy
Kagoya, Yuki; Nakatsugawa, Munehide; Ochi, Toshiki; Guo, Tingxi; Anczurowski, Mark; Saso, Kayoko; Butler, Marcus O.
2017-01-01
Adoptive cell therapy is a potentially curative therapeutic approach for patients with cancer. In this treatment modality, antitumor T cells are exponentially expanded in vitro prior to infusion. Importantly, the results of recent clinical trials suggest that the quality of expanded T cells critically affects their therapeutic efficacy. Although anti-CD3 mAb-based stimulation is widely used to expand T cells in vitro, a protocol to generate T cell grafts for optimal adoptive therapy has yet to be established. In this study, we investigated the differences between T cell stimulation mediated by anti–CD3/CD28 mAb–coated beads and cell-based artificial antigen-presenting cells (aAPCs) expressing CD3/CD28 counter-receptors. We found that transient stimulation with cell-based aAPCs, but not prolonged stimulation with beads, resulted in the superior expansion of CD8+ T cells. Transiently stimulated CD8+ T cells maintained a stem cell–like memory phenotype and were capable of secreting multiple cytokines significantly more efficiently than chronically stimulated T cells. Importantly, the chimeric antigen receptor–engineered antitumor CD8+ T cells expanded via transient stimulation demonstrated superior persistence and antitumor responses in adoptive immunotherapy mouse models. These results suggest that restrained stimulation is critical for generating T cell grafts for optimal adoptive immunotherapy for cancer. PMID:28138559
Transient stimulation expands superior antitumor T cells for adoptive therapy.
Kagoya, Yuki; Nakatsugawa, Munehide; Ochi, Toshiki; Cen, Yuchen; Guo, Tingxi; Anczurowski, Mark; Saso, Kayoko; Butler, Marcus O; Hirano, Naoto
2017-01-26
Adoptive cell therapy is a potentially curative therapeutic approach for patients with cancer. In this treatment modality, antitumor T cells are exponentially expanded in vitro prior to infusion. Importantly, the results of recent clinical trials suggest that the quality of expanded T cells critically affects their therapeutic efficacy. Although anti-CD3 mAb-based stimulation is widely used to expand T cells in vitro, a protocol to generate T cell grafts for optimal adoptive therapy has yet to be established. In this study, we investigated the differences between T cell stimulation mediated by anti-CD3/CD28 mAb-coated beads and cell-based artificial antigen-presenting cells (aAPCs) expressing CD3/CD28 counter-receptors. We found that transient stimulation with cell-based aAPCs, but not prolonged stimulation with beads, resulted in the superior expansion of CD8 + T cells. Transiently stimulated CD8 + T cells maintained a stem cell-like memory phenotype and were capable of secreting multiple cytokines significantly more efficiently than chronically stimulated T cells. Importantly, the chimeric antigen receptor-engineered antitumor CD8 + T cells expanded via transient stimulation demonstrated superior persistence and antitumor responses in adoptive immunotherapy mouse models. These results suggest that restrained stimulation is critical for generating T cell grafts for optimal adoptive immunotherapy for cancer.
Forster, Marie-Therese; Hoecker, Alexander Claudius; Kang, Jun-Suk; Quick, Johanna; Seifert, Volker; Hattingen, Elke; Hilker, Rüdiger; Weise, Lutz Martin
2015-06-01
Tractography based on diffusion tensor imaging has become a popular tool for delineating white matter tracts for neurosurgical procedures. To explore whether navigated transcranial magnetic stimulation (nTMS) might increase the accuracy of fiber tracking. Tractography was performed according to both anatomic delineation of the motor cortex (n = 14) and nTMS results (n = 9). After implantation of the definitive electrode, stimulation via the electrode was performed, defining a stimulation threshold for eliciting motor evoked potentials recorded during deep brain stimulation surgery. Others have shown that of arm and leg muscles. This threshold was correlated with the shortest distance between the active electrode contact and both fiber tracks. Results were evaluated by correlation to motor evoked potential monitoring during deep brain stimulation, a surgical procedure causing hardly any brain shift. Distances to fiber tracks clearly correlated with motor evoked potential thresholds. Tracks based on nTMS had a higher predictive value than tracks based on anatomic motor cortex definition (P < .001 and P = .005, respectively). However, target site, hemisphere, and active electrode contact did not influence this correlation. The implementation of tractography based on nTMS increases the accuracy of fiber tracking. Moreover, this combination of methods has the potential to become a supplemental tool for guiding electrode implantation.
State of the Art: Novel Applications for Cortical Stimulation.
De Ridder, Dirk; Perera, Sanjaya; Vanneste, Sven
2017-04-01
Electrical stimulation via implanted electrodes that overlie the cortex of the brain is an upcoming neurosurgical technique that was hindered for a long time by insufficient knowledge of how the brain functions in a dynamic, physiological, and pathological way, as well as by technological limitations of the implantable stimulation devices. This paper provides an overview of cortex stimulation via implantable devices and introduces future possibilities to improve cortex stimulation. Cortex stimulation was initially used preoperatively as a technique to localize functions in the brain and only later evolved into a treatment technique. It was first used for pain, but more recently a multitude of pathologies are being targeted by cortex stimulation. These disorders are being treated by stimulating different cortical areas of the brain. Risks and complications are essentially similar to those related to deep brain stimulation and predominantly include haemorrhage, seizures, infection, and hardware failures. For cortex stimulation to fully mature, further technological development is required to predict its outcomes and improve stimulation designs. This includes the development of network science-based functional connectivity approaches, genetic analyses, development of navigated high definition transcranial alternating current stimulation, and development of pseudorandom stimulation designs for preventing habituation. In conclusion, cortex stimulation is a nascent but very promising approach to treating a variety of diseases, but requires further technological development for predicting outcomes, such as network science based functional connectivity approaches, genetic analyses, development of navigated transcranial electrical stimulation, and development of pseudorandom stimulation designs for preventing habituation. © 2017 International Neuromodulation Society.
Min, Yong; Yang, Yanyin; Poojari, Yadagiri; Liu, Yidong; Wu, Jen-Chieh; Hansford, Derek J; Epstein, Arthur J
2013-06-10
Electrically conducting polymers (CPs) were found to stimulate various cell types such as neurons, osteoblasts, and fibroblasts in both in vitro and in vivo studies. However, to our knowledge, no studies have been reported on the utility of CPs in stimulation of cancer or tumor cells in the literature. Here we report a facile fabrication method of self-doped sulfonated polyaniline (SPAN)-based interdigitated electrodes (IDEs) for controlled electrical stimulation of human osteosarcoma (HOS) cells. Increased degree of sulfonation was found to increase the SPAN conductivity, which in turn improved the cell attachment and cell growth without electrical stimulation. However, an enhanced cell growth was observed under controlled electrical (AC) stimulation at low applied voltage and frequency (≤800 mV and ≤1 kHz). The cell growth reached a maximum threshold at an applied voltage or frequency and beyond which pronounced cell death was observed. We believe that these organic electrodes may find utility in electrical stimulation of cancer or tumor cells for therapy and research and may also provide an alternative to the conventional metal-based electrodes.
An improved genetic algorithm for designing optimal temporal patterns of neural stimulation
NASA Astrophysics Data System (ADS)
Cassar, Isaac R.; Titus, Nathan D.; Grill, Warren M.
2017-12-01
Objective. Electrical neuromodulation therapies typically apply constant frequency stimulation, but non-regular temporal patterns of stimulation may be more effective and more efficient. However, the design space for temporal patterns is exceedingly large, and model-based optimization is required for pattern design. We designed and implemented a modified genetic algorithm (GA) intended for design optimal temporal patterns of electrical neuromodulation. Approach. We tested and modified standard GA methods for application to designing temporal patterns of neural stimulation. We evaluated each modification individually and all modifications collectively by comparing performance to the standard GA across three test functions and two biophysically-based models of neural stimulation. Main results. The proposed modifications of the GA significantly improved performance across the test functions and performed best when all were used collectively. The standard GA found patterns that outperformed fixed-frequency, clinically-standard patterns in biophysically-based models of neural stimulation, but the modified GA, in many fewer iterations, consistently converged to higher-scoring, non-regular patterns of stimulation. Significance. The proposed improvements to standard GA methodology reduced the number of iterations required for convergence and identified superior solutions.
Fluid shifts and muscle function in humans during acute simulated weightlessness
NASA Technical Reports Server (NTRS)
Hargens, A. R.; Tipton, C. M.; Gollnick, P. D.; Mubarak, S. J.; Tucker, B. J.; Akeson, W. H.
1983-01-01
The acute effects of simulated weightlessness on transcapillary fluid balance, tissue fluid shifts, muscle function, and triceps surface reflex time were studied in eight supine human subjects who were placed in a 5 degrees head-down tilt position for 8 hr. Results show a cephalic fluid shift from the legs as indicated by facial edema, nasal congestion, increased urine flow, decreased creatinine excretion, reduced calf girth, and decreased lower leg volume. The interstitial fluid pressure in the tibialis anterior muscle and subcutaneous tissue of the lower leg was found to fall significantly, while other transcapillary pressures (capillary and interstitial fluid colloid osmotic pressures) were relatively unchanged. The total water content of the soleus muscle was unchanged during the head-down tilt. After head-down tilt, isometric strength and isokinetic strength of the plantar flexors were unchanged, while the triceps surae reflex time associated with plantar flexion movement slowed slightly. These results demonstrate a dehydration effect of head-down tilt on muscle and subcutaneous tissue of the lower leg that may affect muscle function.
Distribution and Depletion of Ractopamine in Goat Plasma, Urine and Various Muscle Tissues.
Zhao, Zhen; Gu, Xu; Su, Xiaoou; Li, Junguo; Li, Jun; Dong, Yingchao; Yang, Yujuan; Yao, Ting; Qin, Yuchang
2017-01-01
This study investigated the ractopamine (RAC) distribution and depletion process in goat plasma, urine and various muscle tissues which were associated with a potential risk for consumer health. The experiment was carried out in 21 goats (18 treated and 3 controls). Treated animals were administered orally a dose of 1 mg/kg body mass per day for 28 consecutive days and randomly sacrificed on Days 0.25, 1, 3, 7, 14 and 21 of the withdrawal period. RAC in goat samples was analyzed by using ultra-high performance liquid chromatography-quadrupole-orbitrap high-resolution mass spectrometry. RAC was below the limits of detection (LOD = 0.15 ng/mL) in plasma while which was higher than the LOD in urine on withdrawal day 21. The residues in goat longissimus dorsi muscle, biceps femoris muscle and triceps surae muscle were differed significantly. These findings demonstrated that urine can be used as the target matrix for monitoring RAC abuse in goat. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Medial compressible forefoot sole elements reduce ankle inversion in lateral SSC jumps.
Fleischmann, Jana; Mornieux, Guillaume; Gehring, Dominic; Gollhofer, Albert
2013-06-01
Sideward movements are associated with high incidences of lateral ankle sprains. Special shoe constructions might be able to reduce these injuries during lateral movements. The purpose of this study was to investigate whether medial compressible forefoot sole elements can reduce ankle inversion in a reactive lateral movement, and to evaluate those elements' influence on neuromuscular and mechanical adjustments in lower extremities. Foot placement and frontal plane ankle joint kinematics and kinetics were analyzed by 3-dimensional motion analysis. Electromyographic data of triceps surae, peroneus longus, and tibialis anterior were collected. This modified shoe reduced ankle inversion in comparison with a shoe with a standard sole construction. No differences in ankle inversion moments were found. With the modified shoe, foot placement occurred more internally rotated, and muscle activity of the lateral shank muscles was reduced. Hence, lateral ankle joint stability during reactive sideward movements can be improved by these compressible elements, and therefore lower lateral shank muscle activity is required. As those elements limit inversion, the strategy to control inversion angles via a high external foot rotation does not need to be used.
The Effects of Local Vibration on Balance, Power, and Self-Reported Pain After Exercise.
Custer, Lisa; Peer, Kimberly S; Miller, Lauren
2017-05-01
Muscle fatigue and acute muscle soreness occur after exercise. Application of a local vibration intervention may reduce the consequences of fatigue and soreness. To examine the effects of a local vibration intervention after a bout of exercise on balance, power, and self-reported pain. Single-blind crossover study. Laboratory. 19 healthy, moderately active subjects. After a 30-min bout of full-body exercise, subjects received either an active or a sham vibration intervention. The active vibration intervention was performed bilaterally over the muscle bellies of the triceps surae, quadriceps, hamstrings, and gluteals. At least 1 wk later, subjects repeated the bout, receiving the other vibration intervention. Static balance, dynamic balance, power, and self-reported pain were measured at baseline, after the vibration intervention, and 24 h postexercise. After the bout of exercise, subjects had reduced static and dynamic balance and increased self-reported pain regardless of vibration intervention. There were no differences between outcome measures between the active and sham vibration conditions. The local vibration intervention did not affect balance, power, or self-reported pain.
The influence of aging on the isometric torque sharing patterns among the plantar flexor muscles.
Oliveira, Liliam F; Verneque, Debora; Menegaldo, Luciano L
2017-01-01
Physiological cross-sectional area (PCSA) reduction of the triceps surae (TS) muscles during aging suggests a proportional loss of torque among its components: soleus, medial and lateral gastrocnemii. However, direct measurements of muscle forces in vivo are not feasible. The purpose of this paper was to compare, between older and young women, isometric ankle joint torque sharing patterns among TS muscles and tibialis anterior (TA). An EMG-driven model was used for estimating individual muscle torque contributions to the total plantar flexor torque, during sustained contractions of 10% and 40% of maximum voluntary contraction (MVC). Relative individual muscle contributions to the total plantar flexion torque were similar between older and young women groups, for both intensities, increasing from LG, MG to SOL. Muscle strength (muscle torque/body mass) was significantly greater for all TS components in 40% MVC contractions. Increased TA activation was observed in 10% of MVC for older people. Despite the reduced maximum isometric torque and muscle strength, the results suggest small variations of ankle muscle synergies during the aging process.
Panerai, Simonetta; Tasca, Domenica; Lanuzza, Bartolo; Trubia, Grazia; Ferri, Raffaele; Musso, Sabrina; Alagona, Giovanna; Di Guardo, Giuseppe; Barone, Concetta; Gaglione, Maria P; Elia, Maurizio
2014-08-01
This report, based on four studies with children with low-functioning autism, aimed at evaluating the effects of repetitive transcranial magnetic stimulation delivered on the left and right premotor cortices on eye-hand integration tasks; defining the long-lasting effects of high-frequency repetitive transcranial magnetic stimulation; and investigating the real efficacy of high-frequency repetitive transcranial magnetic stimulation by comparing three kinds of treatments (high-frequency repetitive transcranial magnetic stimulation, a traditional eye-hand integration training, and both treatments combined). Results showed a significant increase in eye-hand performances only when high-frequency repetitive transcranial magnetic stimulation was delivered on the left premotor cortex; a persistent improvement up to 1 h after the end of the stimulation; better outcomes in the treatment combining high-frequency repetitive transcranial magnetic stimulation and eye-hand integration training. Based on these preliminary findings, further evaluations on the usefulness of high-frequency repetitive transcranial magnetic stimulation in rehabilitation of children with autism are strongly recommended. © The Author(s) 2013.
OceanNOMADS: Real-time and retrospective access to operational U.S. ocean prediction products
NASA Astrophysics Data System (ADS)
Harding, J. M.; Cross, S. L.; Bub, F.; Ji, M.
2011-12-01
The National Oceanic and Atmospheric Administration (NOAA) National Operational Model Archive and Distribution System (NOMADS) provides both real-time and archived atmospheric model output from servers at the National Centers for Environmental Prediction (NCEP) and National Climatic Data Center (NCDC) respectively (http://nomads.ncep.noaa.gov/txt_descriptions/marRutledge-1.pdf). The NOAA National Ocean Data Center (NODC) with NCEP is developing a complementary capability called OceanNOMADS for operational ocean prediction models. An NCEP ftp server currently provides real-time ocean forecast output (http://www.opc.ncep.noaa.gov/newNCOM/NCOM_currents.shtml) with retrospective access through NODC. A joint effort between the Northern Gulf Institute (NGI; a NOAA Cooperative Institute) and the NOAA National Coastal Data Development Center (NCDDC; a division of NODC) created the developmental version of the retrospective OceanNOMADS capability (http://www.northerngulfinstitute.org/edac/ocean_nomads.php) under the NGI Ecosystem Data Assembly Center (EDAC) project (http://www.northerngulfinstitute.org/edac/). Complementary funding support for the developmental OceanNOMADS from U.S. Integrated Ocean Observing System (IOOS) through the Southeastern University Research Association (SURA) Model Testbed (http://testbed.sura.org/) this past year provided NODC the analogue that facilitated the creation of an NCDDC production version of OceanNOMADS (http://www.ncddc.noaa.gov/ocean-nomads/). Access tool development and storage of initial archival data sets occur on the NGI/NCDDC developmental servers with transition to NODC/NCCDC production servers as the model archives mature and operational space and distribution capability grow. Navy operational global ocean forecast subsets for U.S waters comprise the initial ocean prediction fields resident on the NCDDC production server. The NGI/NCDDC developmental server currently includes the Naval Research Laboratory Inter-America Seas Nowcast/Forecast System over the Gulf of Mexico from 2004-Mar 2011, the operational Naval Oceanographic Office (NAVOCEANO) regional USEast ocean nowcast/forecast system from early 2009 to present, and the NAVOCEANO operational regional AMSEAS (Gulf of Mexico/Caribbean) ocean nowcast/forecast system from its inception 25 June 2010 to present. AMSEAS provided one of the real-time ocean forecast products accessed by NOAA's Office of Response and Restoration from the NGI/NCDDC developmental OceanNOMADS during the Deep Water Horizon oil spill last year. The developmental server also includes archived, real-time Navy coastal forecast products off coastal Japan in support of U.S./Japanese joint efforts following the 2011 tsunami. Real-time NAVOCEANO output from regional prediction systems off Southern California and around Hawaii, currently available on the NCEP ftp server, are scheduled for archival on the developmental OceanNOMADS by late 2011 along with the next generation Navy/NOAA global ocean prediction output. Accession and archival of additional regions is planned as server capacities increase.
Plantar fascia anatomy and its relationship with Achilles tendon and paratenon.
Stecco, Carla; Corradin, Marco; Macchi, Veronica; Morra, Aldo; Porzionato, Andrea; Biz, Carlo; De Caro, Raffaele
2013-12-01
Although the plantar fascia (PF) has been studied quite well from a biomechanical viewpoint, its microscopic properties have been overlooked: nothing is known about its content of elastic fibers, the features of the extracellular matrix or the extent of innervation. From a functional and clinical standpoint, the PF is often correlated with the triceps surae muscle, but the anatomical grounds for this link are not clear. The aim of this work was to focus on the PF macroscopic and microscopic properties and study how Achilles tendon diseases might affect it. Twelve feet from unembalmed human cadavers were dissected to isolate the PF. Specimens from each PF were tested with various histological and immunohistochemical stains. In a second stage, 52 magnetic resonance images (MRI) obtained from patients complaining of aspecific ankle or foot pain were analyzed, dividing the cases into two groups based on the presence or absence of signs of degeneration and/or inflammation of the Achilles tendon. The thickness of PF and paratenon was assessed in the two groups and statistical analyses were conducted. The PF is a tissue firmly joined to plantar muscles and skin. Analyzing its possible connections to the sural structures showed that this fascia is more closely connected to the paratenon of Achilles tendon than to the Achilles tendon, through the periosteum of the heel. The PF extended medially and laterally, continuing into the deep fasciae enveloping the abductor hallucis and abductor digiti minimi muscles, respectively. The PF was rich in hyaluronan, probably produced by fibroblastic-like cells described as 'fasciacytes'. Nerve endings and Pacini and Ruffini corpuscles were present, particularly in the medial and lateral portions, and on the surface of the muscles, suggesting a role for the PF in the proprioception of foot. In the radiological study, 27 of the 52 MRI showed signs of Achilles tendon inflammation and/or degeneration, and the PF was 3.43 ± 0.48 mm thick (99%CI and SD = 0.95), as opposed to 2.09 ± 0.24 mm (99%CI, SD = 0.47) in the patients in which the MRI revealed no Achilles tendon diseases; this difference in thickness of 1.29 ± 0.57 mm (99%CI) was statistically significant (P < 0.001). In the group of 27/52 patients with tendinopathies, the PF was more than 4.5 mm thick in 5, i.e. they exceeded the threshold for a diagnosis of plantar fasciitis. None of the other 25/52 paitents had a PF more than 4 mm thick. There was a statistically significant correlation between the thicknesses of the PF and the paratenon. These findings suggest that the plantar fascia has a role not only in supporting the longitudinal arch of the foot, but also in its proprioception and peripheral motor coordination. Its relationship with the paratenon of the Achilles tendon is consistent with the idea of triceps surae structures being involved in the PF pathology, so their rehabilitation can be considered appropriate. Finally, the high concentration of hyaluronan in the PF points to the feasibility of using hyaluronan injections in the fascia to treat plantar fasciitis. © 2013 Anatomical Society.
van den Hoorn, Wolbert; Kerr, Graham K.; van Dieën, Jaap H.; Hodges, Paul W.
2018-01-01
Aging is associated with changes in balance control and elderly take longer to adapt to changing sensory conditions, which may increase falls risk. Low amplitude calf muscle vibration stimulates local sensory afferents/receptors and affects sense of upright when applied in stance. It has been used to assess the extent the nervous system relies on calf muscle somatosensory information and to rapidly change/perturb part of the somatosensory information causing balance unsteadiness by addition and removal of the vibratory stimulus. This study assessed the effect of addition and removal of calf vibration on balance control (in the absence of vision) in elderly individuals (>65 years, n = 99) who did (n = 41) or did not prospectively report falls (n = 58), and in a group of young individuals (18–25 years, n = 23). Participants stood barefoot and blindfolded on a force plate for 135 s. Vibrators (60 Hz, 1 mm) attached bilaterally over the triceps surae muscles were activated twice for 15 s; after 15 and 75 s (45 s for recovery). Balance measures were applied in a windowed (15 s epoch) manner to compare center-of-pressure (CoP) motion before, during and after removal of calf vibration between groups. In each epoch, CoP motion was quantified using linear measures, and non-linear measures to assess temporal structure of CoP motion [using recurrence quantification analysis (RQA) and detrended fluctuation analysis]. Mean CoP displacement during and after vibration did not differ between groups, which suggests that calf proprioception and/or weighting assigned by the nervous system to calf proprioception was similar for the young and both groups of older individuals. Overall, compared to the elderly, CoP motion of young was more predictable and persistent. Balance measures were not different between fallers and non-fallers before and during vibration. However, non-linear aspects of CoP motion of fallers and non-fallers differed after removal of vibration, when dynamic re-weighting is required. During this period fallers exhibited more random CoP motion, which could result from a reduced ability to control balance and/or a reduced ability to dynamically reweight proprioceptive information. These results show that non-linear measures of balance provide evidence for deficits in balance control in people who go on to fall in the following 12 months. PMID:29632494
Evoked EMG-based torque prediction under muscle fatigue in implanted neural stimulation
NASA Astrophysics Data System (ADS)
Hayashibe, Mitsuhiro; Zhang, Qin; Guiraud, David; Fattal, Charles
2011-10-01
In patients with complete spinal cord injury, fatigue occurs rapidly and there is no proprioceptive feedback regarding the current muscle condition. Therefore, it is essential to monitor the muscle state and assess the expected muscle response to improve the current FES system toward adaptive force/torque control in the presence of muscle fatigue. Our team implanted neural and epimysial electrodes in a complete paraplegic patient in 1999. We carried out a case study, in the specific case of implanted stimulation, in order to verify the corresponding torque prediction based on stimulus evoked EMG (eEMG) when muscle fatigue is occurring during electrical stimulation. Indeed, in implanted stimulation, the relationship between stimulation parameters and output torques is more stable than external stimulation in which the electrode location strongly affects the quality of the recruitment. Thus, the assumption that changes in the stimulation-torque relationship would be mainly due to muscle fatigue can be made reasonably. The eEMG was proved to be correlated to the generated torque during the continuous stimulation while the frequency of eEMG also decreased during fatigue. The median frequency showed a similar variation trend to the mean absolute value of eEMG. Torque prediction during fatigue-inducing tests was performed based on eEMG in model cross-validation where the model was identified using recruitment test data. The torque prediction, apart from the potentiation period, showed acceptable tracking performances that would enable us to perform adaptive closed-loop control through implanted neural stimulation in the future.
North, James M; Hong, Kyung-Soo Jason; Cho, Philip Young
2016-10-01
Pain relief via spinal cord stimulation (SCS) has historically revolved around producing paresthesia to replace pain, with success measured by the extent of paresthesia-pain overlap. In a recent murine study, by Shechter et al., showed the superior efficacy of high frequency SCS (1 kHz and 10 kHz) at inhibiting the effects of mechanical hypersensitivity compared to sham or 50 Hz stimulation. In the same study, authors report there were no differences in efficacy between 1 kHz and 10 kHz delivered at subperception stimulation strength (80% of motor threshold). Therefore, we designed a randomized, 2 × 2 crossover study of low frequency supra-perception SCS vs. subperception SCS at 1 kHz frequency in order to test whether subperception stimulation at 1 kHz was sufficient to provide effective pain relief in human subjects. Twenty-two subjects with SCS, and inadequate pain relief based on numeric pain rating scale (NPRS) scores (>5) were enrolled, and observed for total of seven weeks (three weeks of treatment, one week wash off, and another three weeks of treatment). Subjects were asked to rate their pain on NPRS as a primary efficacy variable, and complete the Oswestry Disability Index (ODI) and Patient's Global Impression of Change (PGIC) as secondary outcome measures. Out of 22 subjects that completed the study, 21 subjects (95%) reported improvements in average, best, and worst pain NPRS scores. All NPRS scores were significantly lower with subperception stimulation compared to paresthesia-based stimulation (p < 0.01, p < 0.05, and p < 0.05, respectively). As with NPRS scores, the treatment effect of subperception stimulation was significantly greater than that of paresthesia based stimulation on ODI scores (p = 3.9737 × 10 -5 ) and PGIC scores (p = 3.0396 × 10 -5 ). © 2016 International Neuromodulation Society.
ERIC Educational Resources Information Center
Pang, Katherine
2010-01-01
The purpose of this paper is to present a novel way to stimulate learning, creativity, and thinking based on a new understanding of activity-based learning (ABL) and two methods for developing metacognitive-based activities for the classroom. ABL, in this model, is based on the premise that teachers are distillers and facilitators of information…
NASA Astrophysics Data System (ADS)
Fukuda, Hiroshi; Odagaki, Masato; Hiwaki, Osamu
Motor evoked potentials (MEPs) elicited by transcranial magnetic stimulation (TMS) over the primary motor cortex (M1) vary in their amplitude from trial to trial. To investigate the functions of motor cortex by TMS, it is necessary to confirm the causal relationship between stimulated sites and variable MEPs. We created artificial neural networks to classify sets of variable MEP signals and finger forces into the corresponding stimulated sites. We conducted TMS at three different positions over M1 and measured MEPs of hand and forearm muscles and forces of the index finger in four subjects. We estimated the sites within motor cortex stimulated by TMS based on cortical columnar structure and nerve excitation properties. Finally, we tried to classify the various MEPs and finger forces into three groups using artificial neural networks. MEPs and finger forces varied from trial to trial, even if the stimulating coil was fixed on the subject's head. Our proposed neural network was able to identify the MEPs and finger forces with the corresponding stimulated sites in M1. We proposed the artificial neural networks to confirm the TMS-stimulated sites using various MEPs and evoked finger forces.
Karamintziou, Sofia D; Custódio, Ana Luísa; Piallat, Brigitte; Polosan, Mircea; Chabardès, Stéphan; Stathis, Pantelis G; Tagaris, George A; Sakas, Damianos E; Polychronaki, Georgia E; Tsirogiannis, George L; David, Olivier; Nikita, Konstantina S
2017-01-01
Advances in the field of closed-loop neuromodulation call for analysis and modeling approaches capable of confronting challenges related to the complex neuronal response to stimulation and the presence of strong internal and measurement noise in neural recordings. Here we elaborate on the algorithmic aspects of a noise-resistant closed-loop subthalamic nucleus deep brain stimulation system for advanced Parkinson's disease and treatment-refractory obsessive-compulsive disorder, ensuring remarkable performance in terms of both efficiency and selectivity of stimulation, as well as in terms of computational speed. First, we propose an efficient method drawn from dynamical systems theory, for the reliable assessment of significant nonlinear coupling between beta and high-frequency subthalamic neuronal activity, as a biomarker for feedback control. Further, we present a model-based strategy through which optimal parameters of stimulation for minimum energy desynchronizing control of neuronal activity are being identified. The strategy integrates stochastic modeling and derivative-free optimization of neural dynamics based on quadratic modeling. On the basis of numerical simulations, we demonstrate the potential of the presented modeling approach to identify, at a relatively low computational cost, stimulation settings potentially associated with a significantly higher degree of efficiency and selectivity compared with stimulation settings determined post-operatively. Our data reinforce the hypothesis that model-based control strategies are crucial for the design of novel stimulation protocols at the backstage of clinical applications.
A microcontroller-based implantable nerve stimulator used for rats.
Sha, Hong; Zheng, Zheng; Wang, Yan; Ren, Chaoshi
2005-01-01
A microcontroller-based stimulator that can be flexible programmed after it has been implanted into a rat was studied. Programmability enables implanted stimulators to generate customized, complex protocols for experiments. After implantation, a coded light pulse train that contains information of specific identification will unlock a certain stimulator. If a command that changing the parameters is received, the microcontroller will update its flash memory after it affirms the commands. The whole size of it is only 1.6 cubic centimeters, and it can work for a month. The devices have been successfully used in animal behavior experiments, especially on rats.
A programmable and portable NMES device for drop foot correction and blood flow assist applications.
Breen, Paul P; Corley, Gavin J; O'Keeffe, Derek T; Conway, Richard; Olaighin, Gearóid
2009-04-01
The Duo-STIM, a new, programmable and portable neuromuscular stimulation system for drop foot correction and blood flow assist applications is presented. The system consists of a programmer unit and a portable, programmable stimulator unit. The portable stimulator features fully programmable, sensor-controlled, constant-voltage, dual-channel stimulation and accommodates a range of customized stimulation profiles. Trapezoidal and free-form adaptive stimulation intensity envelope algorithms are provided for drop foot correction applications, while time dependent and activity dependent algorithms are provided for blood flow assist applications. A variety of sensor types can be used with the portable unit, including force sensitive resistor-based foot switches and MEMS-based accelerometer and gyroscope devices. The paper provides a detailed description of the hardware and block-level system design for both units. The programming and operating procedures for the system are also presented. Finally, functional bench test results for the system are presented.
A programmable and portable NMES device for drop foot correction and blood flow assist applications.
Breen, Paul P; Corley, Gavin J; O'Keeffe, Derek T; Conway, Richard; OLaighin, Gearoid
2007-01-01
The Duo-STIM, a new, programmable and portable neuromuscular stimulation system for drop foot correction and blood flow assist applications is presented. The system consists of a programmer unit and a portable, programmable stimulator unit. The portable stimulator features fully programmable, sensor-controlled, constant-voltage, dual-channel stimulation and accommodates a range of customized stimulation profiles. Trapezoidal and free-form adaptive stimulation intensity envelope algorithms are provided for drop foot correction applications, while time dependent and activity dependent algorithms are provided for blood flow assist applications. A variety of sensor types can be used with the portable unit, including force sensitive resistor based foot switches and NMES based accelerometer and gyroscope devices. The paper provides a detailed description of the hardware and block-level system design for both units. The programming and operating procedures for the system are also presented. Finally, functional bench test results for the system are presented.
George, Mark S; Aston-Jones, Gary
2010-01-01
Although the preceding chapters discuss much of the new knowledge of neurocircuitry of neuropsychiatric diseases, and an invasive approach to treatment, this chapter describes and reviews the noninvasive methods of testing circuit-based theories and treating neuropsychiatric diseases that do not involve implanting electrodes into the brain or on its surface. These techniques are transcranial magnetic stimulation, vagus nerve stimulation, and transcranial direct current stimulation. Two of these approaches have FDA approval as therapies. PMID:19693003
Kaloyanides, Kristy B.; McCabe, Sean E.; Cranford, James A.; Teter, Christian J.
2008-01-01
Study Objective To examine associations between age at initiation of prescription stimulants and illicit use and abuse of prescription stimulants, alcohol, and other drugs among college students in the United States. Design Web-based survey of college students. Setting A large (full-time undergraduate population > 20,000) university. Intervention A Web-based survey was sent to a random sample of 5389 undergraduate college students plus an additional 1530 undergraduate college students of various ethnic backgrounds over a 2-month period. Measurements and Main Results Alcohol abuse was assessed by including a modified version of the Cut Down, Annoyance, Guilt, Eye-opener (CAGE) instrument. Drug use–related problems were assessed with a slightly modified version of the Drug Abuse Screening Test, short form (DAST-10). The final sample consisted of 4580 undergraduate students (66% response rate). For the analyses, five subgroups were created based on age at initiation of prescription stimulant use: no prescription stimulant use, grades kindergarten (K)–4, grades 5–8, grades 9–12, and college. Undergraduate students to whom stimulants were prescribed in grades K–4 reported similar rates of alcohol and other drug use compared with that of the group that had no prescription stimulant use. For example, students who started prescription stimulants in grades K–4 were no more likely to report coingestion of alcohol and illicit prescription stimulants (odds ratio [OR] 1.4, 95% confidence interval [CI] 0.2–11.5, NS] than the group that had no prescription stimulant use. However, undergraduate students whose prescription stimulant use began in college had significantly higher rates of alcohol and other drug use. For example, students who started a prescription stimulant in college were almost 4 times as likely (OR 3.7, 95% CI 1.9–7.1, p < 0.001) to report at least three positive indicators of drug abuse on the DAST-10 compared with the group that had no prescription stimulant use. Conclusions In concordance with results of previous research, these results indicate that initiation of prescription stimulants during childhood is not associated with increased future use of alcohol and other drugs. PMID:17461701
Lachaine, Jean; Sikirica, Vanja; Mathurin, Karine
2016-01-16
Attention-deficit/hyperactivity disorder (ADHD) is a common psychiatric disorder in children, with worldwide prevalence of ADHD varying from 5.9 to 7.1 %, depending on the reporter. In case of inadequate response to stimulants, combination therapy of stimulants and an adjunctive medication may improve the control of ADHD symptoms, reduce the dose-limiting adverse events, and help control comorbidities. To date, the only medication to be used for adjunctive therapy to psychostimulants is guanfacine extended release (GXR). The aim of this study was to assess the economic impact of GXR as an adjunct therapy with long-acting stimulants (GXR + stimulant) compared to long-acting stimulant monotherapy (stimulant alone) in the treatment of children and adolescents with ADHD in Canada. A Markov model was developed using health states defined based on the clinician-reported Clinical Global Impression-Severity (CGI-S) score (normal, mild, moderate, severe). Transition probabilities were calculated based on patient-level data from a published study. Long-acting stimulants available in Canada were considered in the base-case model: amphetamine mixed salts, methylphenidate HCl formulations, and lisdexamfetamine dimesylate. Analyses were conducted from a Canadian Ministry of Health (MoH; Ontario) and a societal perspective over a 1-year time horizon with weekly cycles. Over a 1-year time horizon, GXR + stimulant was associated with 0.655 quality-adjusted life year (QALY), compared to 0.627 QALY with stimulant alone, for a gain of 0.028 QALY. From a MoH perspective, GXR+ stimulant and stimulant alone were associated with total costs of $CA1,617 and $CA949, respectively (difference of $CA668), which resulted in an incremental cost-effectiveness ratio (ICER) of $CA23,720/QALY. From a societal perspective, GXR + stimulant and stimulant alone were associated with total costs of $CA3,915 and $CA3,582, respectively (difference of $CA334), which resulted in an ICER of $CA11,845/QALY. Probabilistic sensitivity analysis (PSA) of GXR + stimulant showed that it remains a cost-effective strategy in 100 % of the simulations from both perspectives in numerous PSA and one-way sensitivity analyses, relative to a willingness to pay threshold of $50,000/QALY. This economic evaluation demonstrates that GXR + stimulant is cost-effective compared to stimulant alone in the treatment of children and adolescents with ADHD in Canada.
Karamintziou, Sofia D.; Custódio, Ana Luísa; Piallat, Brigitte; Polosan, Mircea; Chabardès, Stéphan; Stathis, Pantelis G.; Tagaris, George A.; Sakas, Damianos E.; Polychronaki, Georgia E.; Tsirogiannis, George L.; David, Olivier; Nikita, Konstantina S.
2017-01-01
Advances in the field of closed-loop neuromodulation call for analysis and modeling approaches capable of confronting challenges related to the complex neuronal response to stimulation and the presence of strong internal and measurement noise in neural recordings. Here we elaborate on the algorithmic aspects of a noise-resistant closed-loop subthalamic nucleus deep brain stimulation system for advanced Parkinson’s disease and treatment-refractory obsessive-compulsive disorder, ensuring remarkable performance in terms of both efficiency and selectivity of stimulation, as well as in terms of computational speed. First, we propose an efficient method drawn from dynamical systems theory, for the reliable assessment of significant nonlinear coupling between beta and high-frequency subthalamic neuronal activity, as a biomarker for feedback control. Further, we present a model-based strategy through which optimal parameters of stimulation for minimum energy desynchronizing control of neuronal activity are being identified. The strategy integrates stochastic modeling and derivative-free optimization of neural dynamics based on quadratic modeling. On the basis of numerical simulations, we demonstrate the potential of the presented modeling approach to identify, at a relatively low computational cost, stimulation settings potentially associated with a significantly higher degree of efficiency and selectivity compared with stimulation settings determined post-operatively. Our data reinforce the hypothesis that model-based control strategies are crucial for the design of novel stimulation protocols at the backstage of clinical applications. PMID:28222198
Park, Dong-Wook; Ness, Jared P; Brodnick, Sarah K; Esquibel, Corinne; Novello, Joseph; Atry, Farid; Baek, Dong-Hyun; Kim, Hyungsoo; Bong, Jihye; Swanson, Kyle I; Suminski, Aaron J; Otto, Kevin J; Pashaie, Ramin; Williams, Justin C; Ma, Zhenqiang
2018-01-23
Electrical stimulation using implantable electrodes is widely used to treat various neuronal disorders such as Parkinson's disease and epilepsy and is a widely used research tool in neuroscience studies. However, to date, devices that help better understand the mechanisms of electrical stimulation in neural tissues have been limited to opaque neural electrodes. Imaging spatiotemporal neural responses to electrical stimulation with minimal artifact could allow for various studies that are impossible with existing opaque electrodes. Here, we demonstrate electrical brain stimulation and simultaneous optical monitoring of the underlying neural tissues using carbon-based, fully transparent graphene electrodes implanted in GCaMP6f mice. Fluorescence imaging of neural activity for varying electrical stimulation parameters was conducted with minimal image artifact through transparent graphene electrodes. In addition, full-field imaging of electrical stimulation verified more efficient neural activation with cathode leading stimulation compared to anode leading stimulation. We have characterized the charge density limitation of capacitive four-layer graphene electrodes as 116.07-174.10 μC/cm 2 based on electrochemical impedance spectroscopy, cyclic voltammetry, failure bench testing, and in vivo testing. This study demonstrates the transparent ability of graphene neural electrodes and provides a method to further increase understanding and potentially improve therapeutic electrical stimulation in the central and peripheral nervous systems.
Desynchronizing electrical and sensory coordinated reset neuromodulation
Popovych, Oleksandr V.; Tass, Peter A.
2012-01-01
Coordinated reset (CR) stimulation is a desynchronizing stimulation technique based on timely coordinated phase resets of sub-populations of a synchronized neuronal ensemble. It has initially been computationally developed for electrical deep brain stimulation (DBS), to enable an effective desynchronization and unlearning of pathological synchrony and connectivity (anti-kindling). Here we computationally show for ensembles of spiking and bursting model neurons interacting via excitatory and inhibitory adaptive synapses that a phase reset of neuronal populations as well as a desynchronization and an anti-kindling can robustly be achieved by direct electrical stimulation or indirect (synaptically-mediated) excitatory and inhibitory stimulation. Our findings are relevant for DBS as well as for sensory stimulation in neurological disorders characterized by pathological neuronal synchrony. Based on the obtained results, we may expect that the local effects in the vicinity of a depth electrode (realized by direct stimulation of the neurons' somata or stimulation of axon terminals) and the non-local CR effects (realized by stimulation of excitatory or inhibitory efferent fibers) of deep brain CR neuromodulation may be similar or even identical. Furthermore, our results indicate that an effective desynchronization and anti-kindling can even be achieved by non-invasive, sensory CR neuromodulation. We discuss the concept of sensory CR neuromodulation in the context of neurological disorders. PMID:22454622
Desynchronizing electrical and sensory coordinated reset neuromodulation.
Popovych, Oleksandr V; Tass, Peter A
2012-01-01
Coordinated reset (CR) stimulation is a desynchronizing stimulation technique based on timely coordinated phase resets of sub-populations of a synchronized neuronal ensemble. It has initially been computationally developed for electrical deep brain stimulation (DBS), to enable an effective desynchronization and unlearning of pathological synchrony and connectivity (anti-kindling). Here we computationally show for ensembles of spiking and bursting model neurons interacting via excitatory and inhibitory adaptive synapses that a phase reset of neuronal populations as well as a desynchronization and an anti-kindling can robustly be achieved by direct electrical stimulation or indirect (synaptically-mediated) excitatory and inhibitory stimulation. Our findings are relevant for DBS as well as for sensory stimulation in neurological disorders characterized by pathological neuronal synchrony. Based on the obtained results, we may expect that the local effects in the vicinity of a depth electrode (realized by direct stimulation of the neurons' somata or stimulation of axon terminals) and the non-local CR effects (realized by stimulation of excitatory or inhibitory efferent fibers) of deep brain CR neuromodulation may be similar or even identical. Furthermore, our results indicate that an effective desynchronization and anti-kindling can even be achieved by non-invasive, sensory CR neuromodulation. We discuss the concept of sensory CR neuromodulation in the context of neurological disorders.
Wireless Passive Stimulation of Engineered Cardiac Tissues.
Liu, Shiyi; Navaei, Ali; Meng, Xueling; Nikkhah, Mehdi; Chae, Junseok
2017-07-28
We present a battery-free radio frequency (RF) microwave activated wireless stimulator, 25 × 42 × 1.6 mm 3 on a flexible substrate, featuring high current delivery, up to 60 mA, to stimulate engineered cardiac tissues. An external antenna shines 2.4 GHz microwave, which is modulated by an inverted pulse to directly control the stimulating waveform, to the wireless passive stimulator. The stimulator is equipped with an on-board antenna, multistage diode multipliers, and a control transistor. Rat cardiomyocytes, seeded on electrically conductive gelatin-based hydrogels, demonstrate synchronous contractions and Ca 2+ transients immediately upon stimulation. Notably, the stimulator output voltage and current profiles match the tissue contraction frequency within 0.5-2 Hz. Overall, our results indicate the promising potential of the proposed wireless passive stimulator for cardiac stimulation and therapy by induction of precisely controlled and synchronous contractions.
Löscher, Wolfgang; Cole, Andrew J; McLean, Michael J
2009-04-01
Physical approaches for the treatment of epilepsy currently under study or development include electrical or magnetic brain stimulators and cooling devices, each of which may be implanted or applied externally. Some devices may stimulate peripheral structures, whereas others may be implanted directly into the brain. Stimulation may be delivered chronically, intermittently, or in response to either manual activation or computer-based detection of events of interest. Physical approaches may therefore ultimately be appropriate for seizure prophylaxis by causing a modification of the underlying substrate, presumably with a reduction in the intrinsic excitability of cerebral structures, or for seizure termination, by interfering with the spontaneous discharge of pathological neuronal networks. Clinical trials of device-based therapies are difficult due to ethical issues surrounding device implantation, problems with blinding, potential carryover effects that may occur in crossover designs if substrate modification occurs, and subject heterogeneity. Unresolved issues in the development of physical treatments include optimization of stimulation parameters, identification of the optimal volume of brain to be stimulated, development of adequate power supplies to stimulate the necessary areas, and a determination that stimulation itself does not promote epileptogenesis or adverse long-term effects on normal brain function.
Computer-Guided Deep Brain Stimulation Programming for Parkinson's Disease.
Heldman, Dustin A; Pulliam, Christopher L; Urrea Mendoza, Enrique; Gartner, Maureen; Giuffrida, Joseph P; Montgomery, Erwin B; Espay, Alberto J; Revilla, Fredy J
2016-02-01
Pilot study to evaluate computer-guided deep brain stimulation (DBS) programming designed to optimize stimulation settings using objective motion sensor-based motor assessments. Seven subjects (five males; 54-71 years) with Parkinson's disease (PD) and recently implanted DBS systems participated in this pilot study. Within two months of lead implantation, the subject returned to the clinic to undergo computer-guided programming and parameter selection. A motion sensor was placed on the index finger of the more affected hand. Software guided a monopolar survey during which monopolar stimulation on each contact was iteratively increased followed by an automated assessment of tremor and bradykinesia. After completing assessments at each setting, a software algorithm determined stimulation settings designed to minimize symptom severities, side effects, and battery usage. Optimal DBS settings were chosen based on average severity of motor symptoms measured by the motion sensor. Settings chosen by the software algorithm identified a therapeutic window and improved tremor and bradykinesia by an average of 35.7% compared with baseline in the "off" state (p < 0.01). Motion sensor-based computer-guided DBS programming identified stimulation parameters that significantly improved tremor and bradykinesia with minimal clinician involvement. Automated motion sensor-based mapping is worthy of further investigation and may one day serve to extend programming to populations without access to specialized DBS centers. © 2015 International Neuromodulation Society.
Fiber-array based optogenetic prosthetic system for stimulation therapy
NASA Astrophysics Data System (ADS)
Gu, Ling; Cote, Chris; Tejeda, Hector; Mohanty, Samarendra
2012-02-01
Recent advent of optogenetics has enabled activation of genetically-targeted neuronal cells using low intensity blue light with high temporal precision. Since blue light is attenuated rapidly due to scattering and absorption in neural tissue, optogenetic treatment of neurological disorders may require stimulation of specific cell types in multiple regions of the brain. Further, restoration of certain neural functions (vision, and auditory etc) requires accurate spatio-temporal stimulation patterns rather than just precise temporal stimulation. In order to activate multiple regions of the central nervous system in 3D, here, we report development of an optogenetic prosthetic comprising of array of fibers coupled to independently-controllable LEDs. This design avoids direct contact of LEDs with the brain tissue and thus does not require electrical and heat isolation, which can non-specifically stimulate and damage the local brain regions. The intensity, frequency, and duty cycle of light pulses from each fiber in the array was controlled independently using an inhouse developed LabView based program interfaced with a microcontroller driving the individual LEDs. While the temporal profile of the light pulses was controlled by varying the current driving the LED, the beam profile emanating from each fiber tip could be sculpted by microfabrication of the fiber tip. The fiber array was used to stimulate neurons, expressing channelrhodopsin-2, in different locations within the brain or retina. Control of neural activity in the mice cortex, using the fiber-array based prosthetic, is evaluated from recordings made with multi-electrode array (MEA). We also report construction of a μLED array based prosthetic for spatio-temporal stimulation of cortex.
Closing the loop of deep brain stimulation
Carron, Romain; Chaillet, Antoine; Filipchuk, Anton; Pasillas-Lépine, William; Hammond, Constance
2013-01-01
High-frequency deep brain stimulation is used to treat a wide range of brain disorders, like Parkinson's disease. The stimulated networks usually share common electrophysiological signatures, including hyperactivity and/or dysrhythmia. From a clinical perspective, HFS is expected to alleviate clinical signs without generating adverse effects. Here, we consider whether the classical open-loop HFS fulfills these criteria and outline current experimental or theoretical research on the different types of closed-loop DBS that could provide better clinical outcomes. In the first part of the review, the two routes followed by HFS-evoked axonal spikes are explored. In one direction, orthodromic spikes functionally de-afferent the stimulated nucleus from its downstream target networks. In the opposite direction, antidromic spikes prevent this nucleus from being influenced by its afferent networks. As a result, the pathological synchronized activity no longer propagates from the cortical networks to the stimulated nucleus. The overall result can be described as a reversible functional de-afferentation of the stimulated nucleus from its upstream and downstream nuclei. In the second part of the review, the latest advances in closed-loop DBS are considered. Some of the proposed approaches are based on mathematical models, which emphasize different aspects of the parkinsonian basal ganglia: excessive synchronization, abnormal firing-rate rhythms, and a deficient thalamo-cortical relay. The stimulation strategies are classified depending on the control-theory techniques on which they are based: adaptive and on-demand stimulation schemes, delayed and multi-site approaches, stimulations based on proportional and/or derivative control actions, optimal control strategies. Some of these strategies have been validated experimentally, but there is still a large reservoir of theoretical work that may point to ways of improving practical treatment. PMID:24391555
Closing the loop of deep brain stimulation.
Carron, Romain; Chaillet, Antoine; Filipchuk, Anton; Pasillas-Lépine, William; Hammond, Constance
2013-12-20
High-frequency deep brain stimulation is used to treat a wide range of brain disorders, like Parkinson's disease. The stimulated networks usually share common electrophysiological signatures, including hyperactivity and/or dysrhythmia. From a clinical perspective, HFS is expected to alleviate clinical signs without generating adverse effects. Here, we consider whether the classical open-loop HFS fulfills these criteria and outline current experimental or theoretical research on the different types of closed-loop DBS that could provide better clinical outcomes. In the first part of the review, the two routes followed by HFS-evoked axonal spikes are explored. In one direction, orthodromic spikes functionally de-afferent the stimulated nucleus from its downstream target networks. In the opposite direction, antidromic spikes prevent this nucleus from being influenced by its afferent networks. As a result, the pathological synchronized activity no longer propagates from the cortical networks to the stimulated nucleus. The overall result can be described as a reversible functional de-afferentation of the stimulated nucleus from its upstream and downstream nuclei. In the second part of the review, the latest advances in closed-loop DBS are considered. Some of the proposed approaches are based on mathematical models, which emphasize different aspects of the parkinsonian basal ganglia: excessive synchronization, abnormal firing-rate rhythms, and a deficient thalamo-cortical relay. The stimulation strategies are classified depending on the control-theory techniques on which they are based: adaptive and on-demand stimulation schemes, delayed and multi-site approaches, stimulations based on proportional and/or derivative control actions, optimal control strategies. Some of these strategies have been validated experimentally, but there is still a large reservoir of theoretical work that may point to ways of improving practical treatment.
Blanco, Nathaniel J; Saucedo, Celeste L; Gonzalez-Lima, F
2017-03-01
This is the first randomized, controlled study comparing the cognitive effects of transcranial laser stimulation on category learning tasks. Transcranial infrared laser stimulation is a new non-invasive form of brain stimulation that shows promise for wide-ranging experimental and neuropsychological applications. It involves using infrared laser to enhance cerebral oxygenation and energy metabolism through upregulation of the respiratory enzyme cytochrome oxidase, the primary infrared photon acceptor in cells. Previous research found that transcranial infrared laser stimulation aimed at the prefrontal cortex can improve sustained attention, short-term memory, and executive function. In this study, we directly investigated the influence of transcranial infrared laser stimulation on two neurobiologically dissociable systems of category learning: a prefrontal cortex mediated reflective system that learns categories using explicit rules, and a striatally mediated reflexive learning system that forms gradual stimulus-response associations. Participants (n=118) received either active infrared laser to the lateral prefrontal cortex or sham (placebo) stimulation, and then learned one of two category structures-a rule-based structure optimally learned by the reflective system, or an information-integration structure optimally learned by the reflexive system. We found that prefrontal rule-based learning was substantially improved following transcranial infrared laser stimulation as compared to placebo (treatment X block interaction: F(1, 298)=5.117, p=0.024), while information-integration learning did not show significant group differences (treatment X block interaction: F(1, 288)=1.633, p=0.202). These results highlight the exciting potential of transcranial infrared laser stimulation for cognitive enhancement and provide insight into the neurobiological underpinnings of category learning. Copyright © 2017 Elsevier Inc. All rights reserved.
EKG-based detection of deep brain stimulation in fMRI studies.
Fiveland, Eric; Madhavan, Radhika; Prusik, Julia; Linton, Renee; Dimarzio, Marisa; Ashe, Jeffrey; Pilitsis, Julie; Hancu, Ileana
2018-04-01
To assess the impact of synchronization errors between the assumed functional MRI paradigm timing and the deep brain stimulation (DBS) on/off cycling using a custom electrocardiogram-based triggering system METHODS: A detector for measuring and predicting the on/off state of cycling deep brain stimulation was developed and tested in six patients in office visits. Three-electrode electrocardiogram measurements, amplified by a commercial bio-amplifier, were used as input for a custom electronics box (e-box). The e-box transformed the deep brain stimulation waveforms into transistor-transistor logic pulses, recorded their timing, and propagated it in time. The e-box was used to trigger task-based deep brain stimulation functional MRI scans in 5 additional subjects; the impact of timing accuracy on t-test values was investigated in a simulation study using the functional MRI data. Following locking to each patient's individual waveform, the e-box was shown to predict stimulation onset with an average absolute error of 112 ± 148 ms, 30 min after disconnecting from the patients. The subsecond accuracy of the e-box in predicting timing onset is more than adequate for our slow varying, 30-/30-s on/off stimulation paradigm. Conversely, the experimental deep brain stimulation onset prediction accuracy in the absence of the e-box, which could be off by as much as 4 to 6 s, could significantly decrease activation strength. Using this detector, stimulation can be accurately synchronized to functional MRI acquisitions, without adding any additional hardware in the MRI environment. Magn Reson Med 79:2432-2439, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.
NASA Astrophysics Data System (ADS)
Gillies, R. G.; Yau, A. W.; James, H. G.; Hussey, G. C.; McWilliams, K. A.
2014-12-01
The enhanced Polar Outflow Probe (ePOP) Canadian small-satellite was launched in September 2013. Included in this suite of eight scientific instruments is the Radio Receiver Instrument (RRI). The RRI has been used to measure VLF and HF radio waves from various ground and spontaneous ionospheric sources. The first dedicated ground transmission that was detected by RRI was from the Saskatoon Super Dual Auroral Radar Network (SuperDARN) radar on Nov. 7, 2013 at 14 MHz. Several other passes over the Saskatoon SuperDARN radar have been recorded since then. Ground transmissions have also been observed from other radars, such as the SPEAR, HAARP, and SURA ionospheric heaters. However, the focus of this study will be on the results obtained from the SuperDARN passes. An analysis of the signal recorded by the RRI provides estimates of signal power, Doppler shift, polarization, absolute time delay, differential mode delay, and angle of arrival. By comparing these parameters to similar parameters derived from ray tracing simulations, ionospheric electron density structures may be detected and measured. Further analysis of the results from the other ground transmitters and future SuperDARN passes will be used to refine these results.
Suydam, Stephen M; Manal, Kurt; Buchanan, Thomas S
2017-07-01
Isometric tasks have been a standard for electromyography (EMG) normalization stemming from anatomic and physiologic stability observed during contraction. Ballistic dynamic tasks have the benefit of eliciting maximum EMG signals for normalization, despite having the potential for greater signal variability. It is the purpose of this study to compare maximum voluntary isometric contraction (MVIC) to nonisometric tasks with increasing degrees of extrinsic variability, ie, joint range of motion, velocity, rate of contraction, etc., to determine if the ballistic tasks, which elicit larger peak EMG signals, are more reliable than the constrained MVIC. Fifteen subjects performed MVIC, isokinetic, maximum countermovement jump, and sprint tasks while EMG was collected from 9 muscles in the quadriceps, hamstrings, and lower leg. The results revealed the unconstrained ballistic tasks were more reliable compared to the constrained MVIC and isokinetic tasks for all triceps surae muscles. The EMG from sprinting was more reliable than the constrained cases for both the hamstrings and vasti. The most reliable EMG signals occurred when the body was permitted its natural, unconstrained motion. These results suggest that EMG is best normalized using ballistic tasks to provide the greatest within-subject reliability, which beneficially yield maximum EMG values.
Muscle fibre recruitment can respond to the mechanics of the muscle contraction.
Wakeling, James M; Uehli, Katrin; Rozitis, Antra I
2006-08-22
This study investigates the motor unit recruitment patterns between and within muscles of the triceps surae during cycling on a stationary ergometer at a range of pedal speeds and resistances. Muscle activity was measured from the soleus (SOL), medial gastrocnemius (MG) and lateral gastrocnemius (LG) using surface electromyography (EMG) and quantified using wavelet and principal component analysis. Muscle fascicle strain rates were quantified using ultrasonography, and the muscle-tendon unit lengths were calculated from the segmental kinematics. The EMG intensities showed that the body uses the SOL relatively more for the higher-force, lower-velocity contractions than the MG and LG. The EMG spectra showed a shift to higher frequencies at faster muscle fascicle strain rates for MG: these shifts were independent of the level of muscle activity, the locomotor load and the muscle fascicle strain. These results indicated that a selective recruitment of the faster motor units occurred within the MG muscle in response to the increasing muscle fascicle strain rates. This preferential recruitment of the faster fibres for the faster tasks indicates that in some circumstances motor unit recruitment during locomotion can match the contractile properties of the muscle fibres to the mechanical demands of the contraction.
Achilles Tendon Adaptation During Transition to a Minimalist Running Style.
Joseph, Michael F; Histen, Katherine; Arntsen, Julia; L'Hereux, Lauren; Defeo, Carmine; Lockwood, Derek; Scheer, Todd; Denegar, Craig R
2017-04-01
Achilles tendons (ATs) adapt to increased loading generated by long-term adoption of a minimalist shoe running style. There may be difference in the chronology and extent of adaptation between the sexes. To learn the chronology of AT adaptations in female and male runners who transitioned to a minimalist running style through a planned, progressive 12-wk transition program. Prospective cohort study of well-trained, traditionally shod runners who transitioned to minimalist shoe running. Repeated laboratory assessment at baseline and 3, 12, and 24 wk after initiating transition program. Fifteen women and 7 men (of 29 enrolled) completed the study. The authors used diagnostic ultrasound and isokinetic dynamometry to generate a force elongation curve and its derivatives at each time point. Greater adaptations were observed in men than in women, with men generating more force and having greater increases in CSA, stiffness, and Young's modulus and less elongation after 12 wk of training. Men demonstrated changes in AT properties that were consistent with increased loading of the triceps surae during exercise. The women demonstrated far smaller changes. Further investigation is warranted to understand when adaptations may occur in women and the implications of altered AT mechanical properties for performance and injury risk.
Transcranial magnetic stimulation: physics, electrophysiology, and applications.
Fatemi-Ardekani, Ali
2008-01-01
Transcranial magnetic stimulation (TMS) is a noninvasive technique used to stimulate the brain. This review will examine the fundamental principles of physics upon which magnetic stimulation is based, the design considerations of the TMS device, and hypotheses about its electrophysiological effects resulting in neuromodulation. TMS is valuable in neurophysiology research and has significant therapeutic potential in clinical neurology and psychiatry. While TMS can modify neuronal currents in the brain, its underlying mechanism remains unknown. Salient applications are included and some suggestions are outlined for future development of magnetic stimulators that could lead to more effective neuronal stimulation and therefore better therapeutic and diagnostic applications.
Investigation of a BeO-based optically stimulated luminescence dosemeter.
Sommer, M; Henniger, J
2006-01-01
The optical sensitivity of BeO-based luminophors has been well-known for many years. The optical stimulation of BeO with blue light is most effective. Then the dosemeters emit luminescent light in the ultraviolet-range around 325 nm. Matched on these facts a simple optically stimulated luminescence (OSL) treatment has been developed. Intense blue light-emitting diodes are used for cw-stimulation. A Hamamatsu solar blind photomultiplier detects the OSL-light. Good separation of both spectral ranges by optical filters is very important. The dosemeter has a linear dose response between approximately 20 muGy and >10 Gy. It was suggested, that a modification of stimulation conditions would allow measurements down to 1 muGy. Fading, photon energy dependence and reproducibility of OSL-signal correspond well with requirements to clinical and personal dosemeters. In addition, basic questions of the OSL-process in BeO have been investigated. A relevant point of interest was the dependency of the OSL-signal on stimulation power.
Just, Timothy P; Jendzjowsky, Nicholas G; DeLorey, Darren S
2015-05-01
Physical inactivity increases the risk of cardiovascular disease and may alter sympathetic nervous system control of vascular resistance. Hindlimb unweighting (HU), a rodent model of physical inactivity, has been shown to diminish sympathetic vasoconstrictor responsiveness and reduce NO synthase expression in isolated skeletal muscle blood vessels. Our understanding of the effects of HU on sympathetic vascular regulation in vivo is very limited. The present findings demonstrate that HU did not alter sympathetic vasoconstrictor responsiveness and NO-mediated inhibition of sympathetic vasoconstriction in resting and contracting skeletal muscle. This study suggests that short-term physical inactivity does not alter in vivo sympathetic vascular control in the skeletal muscle vascular bed at rest and during contraction. We tested the hypothesis that physical inactivity would increase sympathetic vasoconstrictor responsiveness and diminish NO-mediated inhibition of sympathetic vasoconstriction in resting and contracting skeletal muscle. Sprague-Dawley rats (n = 33) were randomly assigned to sedentary time control (S) or hindlimb unweighted (HU) groups for 21 days. Following the intervention, rats were anaesthetized and instrumented for measurement of arterial blood pressure and femoral artery blood flow and stimulation of the lumbar sympathetic chain. The percentage change of femoral vascular conductance (%FVC) in response to sympathetic chain stimulation delivered at 2 and 5 Hz was determined at rest and during triceps surae muscle contraction before (control) and after NO synthase blockade with l-NAME (5 mg kg i.v.). Sympathetic vasoconstrictor responsiveness was not different (P > 0.05) in S and HU rats at rest (S, 2 Hz, -26 ± 8% and 5 Hz, -46 ± 12%; and HU, 2 Hz, -29 ± 9% and 5 Hz, -51 ± 10%) and during contraction (S, 2 Hz, -10 ± 7% and 5 Hz, -23 ± 11%; and HU, 2 Hz, -9 ± 5% and 5 Hz, -22 ± 7%). Nitric oxide synthase blockade caused a similar increase (P > 0.05) in sympathetic vasoconstrictor responsiveness in HU and S rats at rest (S, 2 Hz, -41 ± 7% and 5 Hz, -58 ± 8%; and HU, 2 Hz, -43 ± 6% and 5 Hz, -63 ± 8%) and during muscle contraction (S, 2 Hz, -15 ± 6% and 5 Hz, -31 ± 11%; and HU, 2 Hz, -12 ± 5% and 5 Hz, -29 ± 8%). Skeletal muscle NO synthase expression and ACh-mediated vasodilatation were also not different between HU and S rats. These data suggest that HU does not alter sympathetic vasoconstrictor responsiveness and NO-mediated inhibition of sympathetic vasoconstriction in resting and contracting skeletal muscle. © 2015 The Authors. The Journal of Physiology © 2015 The Physiological Society.
Tunneling modulation of a quantum-well transistor laser
NASA Astrophysics Data System (ADS)
Feng, M.; Qiu, J.; Wang, C. Y.; Holonyak, N.
2016-11-01
Different than the Bardeen and Brattain transistor (1947) with the current gain depending on the ratio of the base carrier spontaneous recombination lifetime to the emitter-collector transit time, the Feng and Holonyak transistor laser current gain depends upon the base electron-hole (e-h) stimulated recombination, the base dielectric relaxation transport, and the collector stimulated tunneling. For the n-p-n transistor laser tunneling operation, the electron-hole pairs are generated at the collector junction under the influence of intra-cavity photon-assisted tunneling, with electrons drifting to the collector and holes drifting to the base. The excess charge in the base lowers the emitter junction energy barrier, allowing emitter electron injection into the base and satisfying charge neutrality via base dielectric relaxation transport (˜femtoseconds). The excess electrons near the collector junction undergo stimulated recombination at the base quantum-well or transport to the collector, thus supporting tunneling current amplification and optical modulation of the transistor laser.
da Silva Marques, Duarte Nuno; da Mata, António Duarte Sola Pereira; Patto, José Maria Vaz; Barcelos, Filipe Alexandre Duarte; de Almeida Rato Amaral, João Pedro; de Oliveira, Miguel Constantino Mendes; Ferreira, Cristina Gutierrez Castanheira
2011-11-01
To compare salivary pH changes and stimulation efficacy of two different gustatory stimulants of salivary secretion (GSSS) in patients with primary Sjögren syndrome. Portuguese Institute for Rheumatological Diseases. Double-blind randomized controlled trial. Eighty patients were randomized to two intervention groups. Sample size was calculated using an alpha error of 0.05 and a beta of 0.20. Participants were randomly assigned to receive a new GSSS containing a weaker malic acid, fluoride and xylitol or a traditionally citric acid-based one. Saliva collection was obtained by established methods at different times. The salivary pH of the samples was determined with a pH meter and a microelectrode. Salivary pH variations and counts of subjects with pH below 4.5 for over 1 min and stimulated salivary flow were the main outcome measures. Both GSSS significantly stimulated salivary output without significant differences between the two groups. The new gustatory stimulant of salivary secretion presented an absolute risk reduction of 52.78% [33.42-72.13 (95% CI)] when compared with the traditional one. In Xerostomic Primary Sjögren syndrome patients, gustatory stimulants of salivary secretion based on acid mail only with fluoride and xylitol present similar salivary stimulation capacity when compared to citric acid-based ones, besides significantly reducing the number of salivary pH drops below 4.5. This could be related to a diminished risk for dental erosion and should be confirmed with further studies. © 2011 John Wiley & Sons A/S.
Stimulation artifact correction method for estimation of early cortico-cortical evoked potentials.
Trebaul, Lena; Rudrauf, David; Job, Anne-Sophie; Mălîia, Mihai Dragos; Popa, Irina; Barborica, Andrei; Minotti, Lorella; Mîndruţă, Ioana; Kahane, Philippe; David, Olivier
2016-05-01
Effective connectivity can be explored using direct electrical stimulations in patients suffering from drug-resistant focal epilepsies and investigated with intracranial electrodes. Responses to brief electrical pulses mimic the physiological propagation of signals and manifest as cortico-cortical evoked potentials (CCEP). The first CCEP component is believed to reflect direct connectivity with the stimulated region but the stimulation artifact, a sharp deflection occurring during a few milliseconds, frequently contaminates it. In order to recover the characteristics of early CCEP responses, we developed an artifact correction method based on electrical modeling of the electrode-tissue interface. The biophysically motivated artifact templates are then regressed out of the recorded data as in any classical template-matching removal artifact methods. Our approach is able to make the distinction between the physiological responses time-locked to the stimulation pulses and the non-physiological component. We tested the correction on simulated CCEP data in order to quantify its efficiency for different stimulation and recording parameters. We demonstrated the efficiency of the new correction method on simulations of single trial recordings for early responses contaminated with the stimulation artifact. The results highlight the importance of sampling frequency for an accurate analysis of CCEP. We then applied the approach to experimental data. The model-based template removal was compared to a correction based on the subtraction of the averaged artifact. This new correction method of stimulation artifact will enable investigators to better analyze early CCEP components and infer direct effective connectivity in future CCEP studies. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.
Berretin-Felix, Giédre; Sia, Isaac; Barikroo, Ali; Carnaby, Giselle D; Crary, Michael A
2016-09-01
This study compared the immediate impact of different transcutaneous electrical stimulation (TES) amplitudes on physiological swallowing effort in healthy older adults versus young adults. Swallowing physiology changes with age. Reduced physiological swallowing effort in older adults including lower lingua-palatal and pharyngeal pressures may increase risk for swallowing dysfunction (i.e. dysphagia). Transcutaneous electrical stimulation (TES) has been advocated as an adjunctive modality to enhance outcomes in exercise-based therapy for individuals with dysphagia. However, significant variation in how TES is applied during therapy remains and the physiological swallowing response to TES is poorly studied, especially in older adults. Physiological change in swallowing associated with no stimulation, sensory stimulation and motor stimulation was compared in 20 young adults versus 14 older adults. Lingua-palatal and pharyngeal manometric pressures assessed physiological swallowing effort. Multivariate analyses identified interactions between age and stimulation amplitude on lingual and pharyngeal functions. Motor stimulation reduced anterior tongue pressure in both age groups but selectively reduced posterior lingua-palatal pressures in young adults only. Sensory stimulation increased base of tongue (BOT) pressures in older adults but decreased BOT pressures in young adults. Motor stimulation increased hypopharyngeal pressures in both groups. Age and TES level interact in determining immediate physiological responses on swallow performance. A one-size-fit-all approach to TES in dysphagia rehabilitation may be misdirected. © 2014 John Wiley & Sons A/S and The Gerodontology Association. Published by John Wiley & Sons Ltd.
In-situ Measurements of the Direction of Propagation of Pump Waves
NASA Astrophysics Data System (ADS)
James, H. G.; Bernhardt, P. A.; Leyser, T.; Siefring, C. L.
2017-12-01
In the course of an experiment to modify the ionosphere, the direction of pump wave propagation is affected by density gradients in the horizontal and vertical directions, fundamentally affecting wave-energy transport. Horizontal gradients on various scales may await a modification attempt as a preexisting state of the ionosphere and/or be changed by the deposition of heater radio-frequency energy. In the results from the Radio Receiver Instrument (RRI) in the enhanced Polar Outflow Probe (e-POP), we have recorded on the order of 100 flights over ionospheric heaters revealing a variety of processes that high-frequency pump waves experience in the ionosphere. E-POP flies on the Canadian satellite CASSIOPE in an elliptic (320 x 1400 km), highly-inclined (81°) orbit. High frequency measurements have been/are being made near SPEAR, HAARP, Sura, EISCAT Heating and Arecibo. Electromagnetic waves from ground-based heaters are detected by the two, orthogonal, 6-m dipoles on the RRI. The high input impedance of the RRI means that the dipoles act as voltage probes, from which the electric field of incoming waves can be simply computed. When combined with cold-magnetoplasma electric-field theory, the relationship of voltages on the two orthogonal dipoles is used to deduce the direction of arrival of an incoming wave in three dimensions. We illustrate the technique by its application to analysis of signals from different transmitters. These results show a variety of pump-wave propagation directions, indicating the complexity of density structure within which modification might take place. Such complexity illustrates the importance of three-dimensional models of density in the vicinity of modification.
Masood, Tahir; Kalliokoski, Kari; Magnusson, S Peter; Bojsen-Møller, Jens; Finni, Taija
2014-07-15
High-load eccentric exercises have been a key component in the conservative management of chronic Achilles tendinopathy. This study investigated the effects of a 12-wk progressive, home-based eccentric rehabilitation program on ankle plantar flexors' glucose uptake (GU) and myoelectric activity and Achilles tendon GU. A longitudinal study design with control (n = 10) and patient (n = 10) groups was used. Surface electromyography (SEMG) from four ankle plantar flexors and GU from the same muscles and the Achilles tendon were measured during submaximal intermittent isometric plantar flexion task. The results indicated that the symptomatic leg was weaker (P < 0.05) than the asymptomatic leg at baseline, but improved (P < 0.001) with eccentric rehabilitation. Additionally, the rehabilitation resulted in greater GU in both soleus (P < 0.01) and lateral gastrocnemius (P < 0.001) in the symptomatic leg, while the asymptomatic leg displayed higher uptake for medial gastrocnemius and flexor hallucis longus (P < 0.05). While both patient legs had higher tendon GU than the controls (P < 0.05), there was no rehabilitation effect on the tendon GU. Concerning SEMG, at baseline, soleus showed more relative activity in the symptomatic leg compared with both the asymptomatic and control legs (P < 0.05), probably reflecting an effort to compensate for the decreased force potential. The rehabilitation resulted in greater SEMG activity in the lateral gastrocnemius (P < 0.01) of the symptomatic leg with no other within- or between-group differences. Eccentric rehabilitation was effective in decreasing subjective severity of Achilles tendinopathy. It also resulted in redistribution of relative electrical activity, but not metabolic activity, within the triceps surae muscle. Copyright © 2014 the American Physiological Society.
Diving Response in Rats: Role of the Subthalamic Vasodilator Area
Golanov, Eugene V.; Shiflett, James M.; Britz, Gavin W.
2016-01-01
Diving response (DR) is a powerful integrative response targeted toward survival of the hypoxic/anoxic conditions. Being present in all animals and humans, it allows to survive adverse conditions like diving. Earlier, we discovered that forehead stimulation affords neuroprotective effect, decreasing infarction volume triggered by permanent occlusion of the middle cerebral artery in rats. We hypothesized that cold stimulation of the forehead induces DR in rats, which, in turn, exerts neuroprotection. We compared autonomic [AP, heart rate (HR), cerebral blood flow (CBF)] and EEG responses to the known DR-triggering stimulus, ammonia stimulation of the nasal mucosa, cold stimulation of the forehead, and cold stimulation of the glabrous skin of the tail base in anesthetized rats. Responses in AP, HR, CBF, and EEG to cold stimulation of the forehead and ammonia vapors instillation into the nasal cavity were comparable and differed significantly from responses to the cold stimulation of the tail base. Excitotoxic lesion of the subthalamic vasodilator area (SVA), which is known to participate in CBF regulation and to afford neuroprotection upon excitation, failed to affect autonomic components of the DR evoked by forehead cold stimulation or nasal mucosa ammonia stimulation. We conclude that cold stimulation of the forehead triggers physiological response comparable to the response evoked by ammonia vapor instillation into nasal cavity, which is considered as stimulus triggering protective DR. These observations may explain the neuroprotective effect of the forehead stimulation. Data demonstrate that SVA does not directly participate in the autonomic adjustments accompanying DR; however, it is involved in diving-evoked modulation of EEG. We suggest that forehead stimulation can be employed as a stimulus capable of triggering oxygen-conserving DR and can be used for neuroprotective therapy. PMID:27708614
NASA Astrophysics Data System (ADS)
González-Fraga, J. A.; Morán, A. L.; Meza-Kubo, V.; Tentori, M.; Santiago, E.
2009-08-01
During a cognitive stimulation session where elders with cognitive decline perform stimulation activities, such as solving puzzles, we observed that they require constant supervision and support from their caregivers, and caregivers must be able to monitor the stimulation activity of more than one patient at a time. In this paper, aiming at providing support for the caregiver, we developed a vision-based system using an Phase-SDF filter that generates a composite reference image which is correlated to a captured wooden-puzzle image. The output correlation value allows to automatically verify the progress on the puzzle solving task, and to assess its completeness and correctness.
Neuromodulation of chronic headaches: position statement from the European Headache Federation
2013-01-01
The medical treatment of patients with chronic primary headache syndromes (chronic migraine, chronic tension-type headache, chronic cluster headache, hemicrania continua) is challenging as serious side effects frequently complicate the course of medical treatment and some patients may be even medically intractable. When a definitive lack of responsiveness to conservative treatments is ascertained and medication overuse headache is excluded, neuromodulation options can be considered in selected cases. Here, the various invasive and non-invasive approaches, such as hypothalamic deep brain stimulation, occipital nerve stimulation, stimulation of sphenopalatine ganglion, cervical spinal cord stimulation, vagus nerve stimulation, transcranial direct current stimulation, repetitive transcranial magnetic stimulation, and transcutaneous electrical nerve stimulation are extensively published although proper RCT-based evidence is limited. The European Headache Federation herewith provides a consensus statement on the clinical use of neuromodulation in headache, based on theoretical background, clinical data, and side effect of each method. This international consensus further gives recommendations for future studies on these new approaches. In spite of a growing field of stimulation devices in headaches treatment, further controlled studies to validate, strengthen and disseminate the use of neurostimulation are clearly warranted. Consequently, until these data are available any neurostimulation device should only be used in patients with medically intractable syndromes from tertiary headache centers either as part of a valid study or have shown to be effective in such controlled studies with an acceptable side effect profile. PMID:24144382
Gorniak, Stacey L.; McIntyre, Cameron C.; Alberts, Jay L.
2013-01-01
Objective Studies of bimanual actions similar to activities of daily living (ADLs) are currently lacking in evaluating fine motor control in Parkinson’s disease patients implanted with bilateral subthalamic deep brain stimulators. We investigated basic time and force characteristics of a bimanual task that resembles performance of ADLs in a group of bilateral subthalamic deep brain stimulation (DBS) patients. Methods Patients were evaluated in three different DBS parameter conditions off stimulation, on clinically derived stimulation parameters, and on settings derived from a patient-specific computational model. Model-based parameters were computed as a means to minimize spread of current to non-motor regions of the subthalamic nucleus via Cicerone Deep Brain Stimulation software. Patients were evaluated off parkinsonian medications in each stimulation condition. Results The data indicate that DBS parameter state does not affect most aspects of fine motor control in ADL-like tasks; however, features such as increased grip force and grip symmetry varied with the stimulation state. In the absence of DBS parameters, patients exhibited significant grip force asymmetry. Overall UPDRS-III and UPDRS-III scores associated with hand function were lower while patients were experiencing clinically-derived or model-based parameters, as compared to the off-stimulation condition. Conclusion While bilateral subthalamic DBS has been shown to alleviate gross motor dysfunction, our results indicate that DBS may not provide the same magnitude of benefit to fine motor coordination. PMID:24244388
Münnich, Timo; Klein, Jan; Hattingen, Elke; Noack, Anika; Herrmann, Eva; Seifert, Volker; Senft, Christian; Forster, Marie-Therese
2018-04-14
Tractography is a popular tool for visualizing the corticospinal tract (CST). However, results may be influenced by numerous variables, eg, the selection of seeding regions of interests (ROIs) or the chosen tracking algorithm. To compare different variable sets by correlating tractography results with intraoperative subcortical stimulation of the CST, correcting intraoperative brain shift by the use of intraoperative MRI. Seeding ROIs were created by means of motor cortex segmentation, functional MRI (fMRI), and navigated transcranial magnetic stimulation (nTMS). Based on these ROIs, tractography was run for each patient using a deterministic and a probabilistic algorithm. Tractographies were processed on pre- and postoperatively acquired data. Using a linear mixed effects statistical model, best correlation between subcortical stimulation intensity and the distance between tractography and stimulation sites was achieved by using the segmented motor cortex as seeding ROI and applying the probabilistic algorithm on preoperatively acquired imaging sequences. Tractographies based on fMRI or nTMS results differed very little, but with enlargement of positive nTMS sites the stimulation-distance correlation of nTMS-based tractography improved. Our results underline that the use of tractography demands for careful interpretation of its virtual results by considering all influencing variables.
1989-01-01
ATPase is a negative charge around the enzyme based on the observation that Ca++/Mg++-ATPase reconstituted in phosphotidylcholine vesicles is...stimulated by calmodulin, but purified ATPase in phosphotidylserine vesicles is not because the enzyme is already maximally active. Stimulation of the
Peirce, Jessica M; Petry, Nancy M; Stitzer, Maxine L; Blaine, Jack; Kellogg, Scott; Satterfield, Frank; Schwartz, Marion; Krasnansky, Joe; Pencer, Eileen; Silva-Vazquez, Lolita; Kirby, Kimberly C; Royer-Malvestuto, Charlotte; Roll, John M; Cohen, Allan; Copersino, Marc L; Kolodner, Ken; Li, Rui
2006-02-01
Contingency management interventions that provide tangible incentives based on objective indicators of drug abstinence have improved treatment outcomes of substance abusers, but have not been widely implemented in community drug abuse treatment settings. To compare outcomes achieved when a lower-cost prize-based contingency management treatment is added to usual care in community methadone hydrochloride maintenance treatment settings. Random assignment to usual care with (n = 198) or without (n = 190) abstinence incentives during a 12-week trial. Six community-based methadone maintenance drug abuse treatment clinics in locations across the United States. Three hundred eighty-eight stimulant-abusing patients enrolled in methadone maintenance programs for at least 1 month and no more than 3 years. Participants submitting stimulant- and alcohol-negative samples earned draws for a chance to win prizes; the number of draws earned increased with continuous abstinence time. Total number of stimulant- and alcohol-negative samples provided, percentage of stimulant- and alcohol-negative samples provided, longest duration of abstinence, retention, and counseling attendance. Submission of stimulant- and alcohol-negative samples was twice as likely for incentive as for usual care group participants (odds ratio, 1.98; 95% confidence interval, 1.42-2.77). Achieving 4 or more, 8 or more, and 12 weeks of continuous abstinence was approximately 3, 9, and 11 times more likely, respectively, for incentive vs usual care participants. Groups did not differ on study retention or counseling attendance. The average cost of prizes was 120 dollars per participant. An abstinence incentive approach that paid 120 dollars in prizes per participant effectively increased stimulant abstinence in community-based methadone maintenance treatment clinics.
Handler, Michael; Schier, Peter P; Fritscher, Karl D; Raudaschl, Patrik; Johnson Chacko, Lejo; Glueckert, Rudolf; Saba, Rami; Schubert, Rainer; Baumgarten, Daniel; Baumgartner, Christian
2017-01-01
Our sense of balance and spatial orientation strongly depends on the correct functionality of our vestibular system. Vestibular dysfunction can lead to blurred vision and impaired balance and spatial orientation, causing a significant decrease in quality of life. Recent studies have shown that vestibular implants offer a possible treatment for patients with vestibular dysfunction. The close proximity of the vestibular nerve bundles, the facial nerve and the cochlear nerve poses a major challenge to targeted stimulation of the vestibular system. Modeling the electrical stimulation of the vestibular system allows for an efficient analysis of stimulation scenarios previous to time and cost intensive in vivo experiments. Current models are based on animal data or CAD models of human anatomy. In this work, a (semi-)automatic modular workflow is presented for the stepwise transformation of segmented vestibular anatomy data of human vestibular specimens to an electrical model and subsequently analyzed. The steps of this workflow include (i) the transformation of labeled datasets to a tetrahedra mesh, (ii) nerve fiber anisotropy and fiber computation as a basis for neuron models, (iii) inclusion of arbitrary electrode designs, (iv) simulation of quasistationary potential distributions, and (v) analysis of stimulus waveforms on the stimulation outcome. Results obtained by the workflow based on human datasets and the average shape of a statistical model revealed a high qualitative agreement and a quantitatively comparable range compared to data from literature, respectively. Based on our workflow, a detailed analysis of intra- and extra-labyrinthine electrode configurations with various stimulation waveforms and electrode designs can be performed on patient specific anatomy, making this framework a valuable tool for current optimization questions concerning vestibular implants in humans.
Jung, Suk Won; Shin, Jong Yoon; Pi, Kilwha; Goo, Yong Sook; Cho, Dong-Il Dan
2016-12-01
This paper proposes a neural stimulation device integrated with a silicon nanowire (SiNW)-based photodetection circuit for the activation of neurons with light. The proposed device is comprised of a voltage divider and a current driver in which SiNWs are used as photodetector and field-effect transistors; it has the functions of detecting light, generating a stimulation signal in proportion to the light intensity, and transmitting the signal to a micro electrode. To show the applicability of the proposed neural stimulation device as a high-resolution retinal prosthesis system, a high-density neural stimulation device with a unit cell size of 110 × 110 μ m and a resolution of 32 × 32 was fabricated on a flexible film with a thickness of approximately 50 μm. Its effectiveness as a retinal stimulation device was then evaluated using a unit cell in an in vitro animal experiment involving the retinal tissue of retinal Degeneration 1 ( rd1 ) mice. Experiments wherein stimulation pulses were applied to the retinal tissues successfully demonstrate that the number of spikes in neural response signals increases in proportion to light intensity.
Comparing models of the combined-stimulation advantage for speech recognition.
Micheyl, Christophe; Oxenham, Andrew J
2012-05-01
The "combined-stimulation advantage" refers to an improvement in speech recognition when cochlear-implant or vocoded stimulation is supplemented by low-frequency acoustic information. Previous studies have been interpreted as evidence for "super-additive" or "synergistic" effects in the combination of low-frequency and electric or vocoded speech information by human listeners. However, this conclusion was based on predictions of performance obtained using a suboptimal high-threshold model of information combination. The present study shows that a different model, based on Gaussian signal detection theory, can predict surprisingly large combined-stimulation advantages, even when performance with either information source alone is close to chance, without involving any synergistic interaction. A reanalysis of published data using this model reveals that previous results, which have been interpreted as evidence for super-additive effects in perception of combined speech stimuli, are actually consistent with a more parsimonious explanation, according to which the combined-stimulation advantage reflects an optimal combination of two independent sources of information. The present results do not rule out the possible existence of synergistic effects in combined stimulation; however, they emphasize the possibility that the combined-stimulation advantages observed in some studies can be explained simply by non-interactive combination of two information sources.
Wang, Xing; Chaudhry, Sharjeel A; Hou, Wensheng; Jia, Xiaofeng
2017-02-05
Stroke leads to serious long-term disability. Electrical epidural cortical stimulation has made significant improvements in stroke rehabilitation therapy. We developed a preliminary wireless implantable passive interface, which consists of a stimulating surface electrode, receiving coil, and single flexible passive demodulated circuit printed by flexible printed circuit (FPC) technique and output pulse voltage stimulus by inductively coupling an external circuit. The wireless implantable board was implanted in cats' unilateral epidural space for electrical stimulation of the primary visual cortex (V1) while the evoked responses were recorded on the contralateral V1 using a needle electrode. The wireless implantable board output stable monophasic voltage stimuli. The amplitude of the monophasic voltage output could be adjusted by controlling the voltage of the transmitter circuit within a range of 5-20 V. In acute experiment, cortico-cortical evoked potential (CCEP) response was recorded on the contralateral V1. The amplitude of N2 in CCEP was modulated by adjusting the stimulation intensity of the wireless interface. These results demonstrated that a wireless interface based on a microcoil array can offer a valuable tool for researchers to explore electrical stimulation in research and the dura mater-electrode interface can effectively transmit electrical stimulation.
Flexible Neural Electrode Array Based-on Porous Graphene for Cortical Microstimulation and Sensing
NASA Astrophysics Data System (ADS)
Lu, Yichen; Lyu, Hongming; Richardson, Andrew G.; Lucas, Timothy H.; Kuzum, Duygu
2016-09-01
Neural sensing and stimulation have been the backbone of neuroscience research, brain-machine interfaces and clinical neuromodulation therapies for decades. To-date, most of the neural stimulation systems have relied on sharp metal microelectrodes with poor electrochemical properties that induce extensive damage to the tissue and significantly degrade the long-term stability of implantable systems. Here, we demonstrate a flexible cortical microelectrode array based on porous graphene, which is capable of efficient electrophysiological sensing and stimulation from the brain surface, without penetrating into the tissue. Porous graphene electrodes show superior impedance and charge injection characteristics making them ideal for high efficiency cortical sensing and stimulation. They exhibit no physical delamination or degradation even after 1 million biphasic stimulation cycles, confirming high endurance. In in vivo experiments with rodents, same array is used to sense brain activity patterns with high spatio-temporal resolution and to control leg muscles with high-precision electrical stimulation from the cortical surface. Flexible porous graphene array offers a minimally invasive but high efficiency neuromodulation scheme with potential applications in cortical mapping, brain-computer interfaces, treatment of neurological disorders, where high resolution and simultaneous recording and stimulation of neural activity are crucial.
Moving-window dynamic optimization: design of stimulation profiles for walking.
Dosen, Strahinja; Popović, Dejan B
2009-05-01
The overall goal of the research is to improve control for electrical stimulation-based assistance of walking in hemiplegic individuals. We present the simulation for generating offline input (sensors)-output (intensity of muscle stimulation) representation of walking that serves in synthesizing a rule-base for control of electrical stimulation for restoration of walking. The simulation uses new algorithm termed moving-window dynamic optimization (MWDO). The optimization criterion was to minimize the sum of the squares of tracking errors from desired trajectories with the penalty function on the total muscle efforts. The MWDO was developed in the MATLAB environment and tested using target trajectories characteristic for slow-to-normal walking recorded in healthy individual and a model with the parameters characterizing the potential hemiplegic user. The outputs of the simulation are piecewise constant intensities of electrical stimulation and trajectories generated when the calculated stimulation is applied to the model. We demonstrated the importance of this simulation by showing the outputs for healthy and hemiplegic individuals, using the same target trajectories. Results of the simulation show that the MWDO is an efficient tool for analyzing achievable trajectories and for determining the stimulation profiles that need to be delivered for good tracking.
Makeyev, Oleksandr; Liu, Xiang; Luna-Munguía, Hiram; Rogel-Salazar, Gabriela; Mucio-Ramirez, Samuel; Liu, Yuhong; Sun, Yan L.; Kay, Steven M.; Besio, Walter G.
2012-01-01
Epilepsy affects approximately one percent of the world population. Antiepileptic drugs are ineffective in approximately 30% of patients and have side effects. We are developing a noninvasive, or minimally invasive, transcranial focal electrical stimulation system through our novel tripolar concentric ring electrodes to control seizures. In this study we demonstrate feasibility of an automatic seizure control system in rats with pentylenetetrazole-induced seizures through single and multiple stimulations. These stimulations are automatically triggered by a real-time electrographic seizure activity detector based on a disjunctive combination of detections from a cumulative sum algorithm and a generalized likelihood ratio test. An average seizure onset detection accuracy of 76.14% was obtained for the test set (n = 13). Detection of electrographic seizure activity was accomplished in advance of the early behavioral seizure activity in 76.92% of the cases. Automatically triggered stimulation significantly (p = 0.001) reduced the electrographic seizure activity power in the once stimulated group compared to controls in 70% of the cases. To the best of our knowledge this is the first closed-loop automatic seizure control system based on noninvasive electrical brain stimulation using tripolar concentric ring electrode electrographic seizure activity as feedback. PMID:22772373
Makeyev, Oleksandr; Liu, Xiang; Luna-Munguía, Hiram; Rogel-Salazar, Gabriela; Mucio-Ramirez, Samuel; Liu, Yuhong; Sun, Yan L; Kay, Steven M; Besio, Walter G
2012-07-01
Epilepsy affects approximately 1% of the world population. Antiepileptic drugs are ineffective in approximately 30% of patients and have side effects. We are developing a noninvasive, or minimally invasive, transcranial focal electrical stimulation system through our novel tripolar concentric ring electrodes to control seizures. In this study, we demonstrate feasibility of an automatic seizure control system in rats with pentylenetetrazole-induced seizures through single and multiple stimulations. These stimulations are automatically triggered by a real-time electrographic seizure activity detector based on a disjunctive combination of detections from a cumulative sum algorithm and a generalized likelihood ratio test. An average seizure onset detection accuracy of 76.14% was obtained for the test set (n = 13). Detection of electrographic seizure activity was accomplished in advance of the early behavioral seizure activity in 76.92% of the cases. Automatically triggered stimulation significantly (p = 0.001) reduced the electrographic seizure activity power in the once stimulated group compared to controls in 70% of the cases. To the best of our knowledge this is the first closed-loop automatic seizure control system based on noninvasive electrical brain stimulation using tripolar concentric ring electrode electrographic seizure activity as feedback.
Chisholm, Amanda E; Malik, Raza Naseem; Blouin, Jean-Sébastien; Borisoff, Jaimie; Forwell, Susan; Lam, Tania
2014-06-06
Previous evidence suggests the effects of task-specific therapy can be further enhanced when sensory stimulation is combined with motor practice. Sensory tongue stimulation is thought to facilitate activation of regions in the brain that are important for balance and gait. Improvements in balance and gait have significant implications for functional mobility for people with incomplete spinal cord injury (iSCI). The aim of this case study was to evaluate the feasibility of a lab- and home-based program combining sensory tongue stimulation with balance and gait training on functional outcomes in people with iSCI. Two male participants (S1 and S2) with chronic motor iSCI completed 12 weeks of balance and gait training (3 lab and 2 home based sessions per week) combined with sensory tongue stimulation using the Portable Neuromodulation Stimulator (PoNS). Laboratory based training involved 20 minutes of standing balance with eyes closed and 30 minutes of body-weight support treadmill walking. Home based sessions consisted of balancing with eyes open and walking with parallel bars or a walker for up to 20 minutes each. Subjects continued daily at-home training for an additional 12 weeks as follow-up. Both subjects were able to complete a minimum of 83% of the training sessions. Standing balance with eyes closed increased from 0.2 to 4.0 minutes and 0.0 to 0.2 minutes for S1 and S2, respectively. Balance confidence also improved at follow-up after the home-based program. Over ground walking speed improved by 0.14 m/s for S1 and 0.07 m/s for S2, and skilled walking function improved by 60% and 21% for S1 and S2, respectively. Sensory tongue stimulation combined with task-specific training may be a feasible method for improving balance and gait in people with iSCI. Our findings warrant further controlled studies to determine the added benefits of sensory tongue stimulation to rehabilitation training.
Baxter, Bryan S; Edelman, Bradley J; Nesbitt, Nicholas; He, Bin
Transcranial direct current stimulation (tDCS) has been used to alter the excitability of neurons within the cerebral cortex. Improvements in motor learning have been found in multiple studies when tDCS was applied to the motor cortex before or during task learning. The motor cortex is also active during the performance of motor imagination, a cognitive task during which a person imagines, but does not execute, a movement. Motor imagery can be used with noninvasive brain computer interfaces (BCIs) to control virtual objects in up to three dimensions, but to master control of such devices requires long training times. To evaluate the effect of high-definition tDCS on the performance and underlying electrophysiology of motor imagery based BCI. We utilize high-definition tDCS to investigate the effect of stimulation on motor imagery-based BCI performance across and within sessions over multiple training days. We report a decreased time-to-hit with anodal stimulation both within and across sessions. We also found differing electrophysiological changes of the stimulated sensorimotor cortex during online BCI task performance for left vs. right trials. Cathodal stimulation led to a decrease in alpha and beta band power during task performance compared to sham stimulation for right hand imagination trials. These results suggest that unilateral tDCS over the sensorimotor motor cortex differentially affects cortical areas based on task specific neural activation. Copyright © 2016 Elsevier Inc. All rights reserved.
Kumar, Deepesh; Verma, Sunny; Bhattacharya, Sutapa; Lahiri, Uttama
2016-06-13
Neurological disorders often manifest themselves in the form of movement deficit on the part of the patient. Conventional rehabilitation often used to address these deficits, though powerful are often monotonous in nature. Adequate audio-visual stimulation can prove to be motivational. In the research presented here we indicate the applicability of audio-visual stimulation to rehabilitation exercises to address at least some of the movement deficits for upper and lower limbs. Added to the audio-visual stimulation, we also use Functional Electrical Stimulation (FES). In our presented research we also show the applicability of FES in conjunction with audio-visual stimulation delivered through VR-based platform for grasping skills of patients with movement disorder.
Design of low-cost general purpose microcontroller based neuromuscular stimulator.
Koçer, S; Rahmi Canal, M; Güler, I
2000-04-01
In this study, a general purpose, low-cost, programmable, portable and high performance stimulator is designed and implemented. For this purpose, a microcontroller is used in the design of the stimulator. The duty cycle and amplitude of the designed system can be controlled using a keyboard. The performance test of the system has shown that the results are reliable. The overall system can be used as the neuromuscular stimulator under safe conditions.
Home Based Early Intervention: The Story of Susan.
ERIC Educational Resources Information Center
Gray, Davon
1980-01-01
Case of a severely handicapped preschooler illustrates advantages of home-based infant stimulation program. Initial goals were: work toward physical separation of mother and child, shape and reinforce child's behavior to extinguish crying, shape and reinforce mother's behavior to enrich home environment, and stimulate and reinforce a developmental…
Microseismic monitoring during Hydraulic stimulation in Pohang (Korea) for EGS pilot project
NASA Astrophysics Data System (ADS)
Kim, M.; Yoon, B.; Lee, C.; Park, K. G.; Yoon, W. S.; Song, Y.; Lee, T. J.
2017-12-01
Since the geothermal anomaly in the Pohang area has been reported in 1960s, various geological and geophysical surveys have been conducted by Korea Institute of Geoscience and Mineral Resources (KIGAM) including gravity, seismic, airborne magnetic and magneto-telluric surveys. Based on these explorations, the Enhanced Geothermal System (EGS) pilot project has been carried out in Pohang since the end of 2010. One vertical well (PX-2, MD 4,348 m) and one deviated well (PX-1, MD 4,362 m) have been drilled in granite rock for the EGS. Microseismic (MS) monitoring is the best way to understand how the fracture grows during the hydraulic stimulation. KIGAM has set up 9 shallow borehole stations (100-130 m), 4 surface stations and two borehole geophones (1,350 and 1,550 m deep) within 5 km radius from injection well for the MS monitoring during hydraulic stimulation. The first hydraulic stimulation started on January 29th to February 20th, 2016 at PX-2 and the second stimulation was conducted in PX-1 from December 15th, 2016 to January 11th, 2017. Several hundreds of MS events occurred during stimulation and the biggest event was ML 2.3 during the shut in period of the second stimulation. Based on the results of the MS monitoring, a soft stimulation is scheduled at PX-1 in cooperation with one of the European Horizon2020 project, DESTRESS (Demonstration of soft stimulation treatments of geothermal reservoirs). We will present the MS monitoring system in Pohang and the data of the stimulation with the MS monitoring results. We believe that the data from Pohang will improve the understanding of seismic behavior due to hydraulic stimulation in crystalline rocks and also will contribute to success of the Pohang EGS project.
den Bosch, Saskia Op; Duch, Helena
2017-08-01
Early childhood obesity disproportionately affects children of low socioeconomic status. Children attending Head Start are reported to have an obesity rate of 17.9%.This longitudinal study aimed to understand the relationship between cognitive stimulation at home and intake of junk food, physical activity and body size, for a nationally representative sample of 3- and 4-year old children entering Head Start. We used The Family and Child Experiences Survey 2006. Cognitive stimulation at home was measured for 1905 children at preschool entry using items from the Home Observation Measurement of the Environment Short Form. Junk food consumption and physical activity were obtained from parent interviews at kindergarten entry. BMI z scores were based on CDC national standards. We analyzed the association between early cognitive stimulation and junk food consumption, physical activity and BMI, using multinomial and binary logistic regression on a weighted sample. Children who received moderate levels of cognitive stimulation at home had a 1.5 increase in the likelihood of consuming low amounts of junk food compared to children from low cognitive stimulation environments. Children who received moderate and high levels of cognitive stimulation were two and three times, respectively, more likely to be physically active than those in low cognitive stimulation homes. No direct relationship was identified between cognitive stimulation and BMI. Prevention and treatment efforts to address early childhood obesity may consider strategies that support parents in providing cognitively stimulating home environments. Existing evidence-based programs can guide intervention in pediatric primary care.
Effect of higher frequency on the classification of steady-state visual evoked potentials
NASA Astrophysics Data System (ADS)
Won, Dong-Ok; Hwang, Han-Jeong; Dähne, Sven; Müller, Klaus-Robert; Lee, Seong-Whan
2016-02-01
Objective. Most existing brain-computer interface (BCI) designs based on steady-state visual evoked potentials (SSVEPs) primarily use low frequency visual stimuli (e.g., <20 Hz) to elicit relatively high SSVEP amplitudes. While low frequency stimuli could evoke photosensitivity-based epileptic seizures, high frequency stimuli generally show less visual fatigue and no stimulus-related seizures. The fundamental objective of this study was to investigate the effect of stimulation frequency and duty-cycle on the usability of an SSVEP-based BCI system. Approach. We developed an SSVEP-based BCI speller using multiple LEDs flickering with low frequencies (6-14.9 Hz) with a duty-cycle of 50%, or higher frequencies (26-34.7 Hz) with duty-cycles of 50%, 60%, and 70%. The four different experimental conditions were tested with 26 subjects in order to investigate the impact of stimulation frequency and duty-cycle on performance and visual fatigue, and evaluated with a questionnaire survey. Resting state alpha powers were utilized to interpret our results from the neurophysiological point of view. Main results. The stimulation method employing higher frequencies not only showed less visual fatigue, but it also showed higher and more stable classification performance compared to that employing relatively lower frequencies. Different duty-cycles in the higher frequency stimulation conditions did not significantly affect visual fatigue, but a duty-cycle of 50% was a better choice with respect to performance. The performance of the higher frequency stimulation method was also less susceptible to resting state alpha powers, while that of the lower frequency stimulation method was negatively correlated with alpha powers. Significance. These results suggest that the use of higher frequency visual stimuli is more beneficial for performance improvement and stability as time passes when developing practical SSVEP-based BCI applications.
Effect of higher frequency on the classification of steady-state visual evoked potentials.
Won, Dong-Ok; Hwang, Han-Jeong; Dähne, Sven; Müller, Klaus-Robert; Lee, Seong-Whan
2016-02-01
Most existing brain-computer interface (BCI) designs based on steady-state visual evoked potentials (SSVEPs) primarily use low frequency visual stimuli (e.g., <20 Hz) to elicit relatively high SSVEP amplitudes. While low frequency stimuli could evoke photosensitivity-based epileptic seizures, high frequency stimuli generally show less visual fatigue and no stimulus-related seizures. The fundamental objective of this study was to investigate the effect of stimulation frequency and duty-cycle on the usability of an SSVEP-based BCI system. We developed an SSVEP-based BCI speller using multiple LEDs flickering with low frequencies (6-14.9 Hz) with a duty-cycle of 50%, or higher frequencies (26-34.7 Hz) with duty-cycles of 50%, 60%, and 70%. The four different experimental conditions were tested with 26 subjects in order to investigate the impact of stimulation frequency and duty-cycle on performance and visual fatigue, and evaluated with a questionnaire survey. Resting state alpha powers were utilized to interpret our results from the neurophysiological point of view. The stimulation method employing higher frequencies not only showed less visual fatigue, but it also showed higher and more stable classification performance compared to that employing relatively lower frequencies. Different duty-cycles in the higher frequency stimulation conditions did not significantly affect visual fatigue, but a duty-cycle of 50% was a better choice with respect to performance. The performance of the higher frequency stimulation method was also less susceptible to resting state alpha powers, while that of the lower frequency stimulation method was negatively correlated with alpha powers. These results suggest that the use of higher frequency visual stimuli is more beneficial for performance improvement and stability as time passes when developing practical SSVEP-based BCI applications.
Electronic design of a multichannel programmable implant for neuromuscular electrical stimulation.
Arabi, K; Sawan, M A
1999-06-01
An advanced stimulator for neuromuscular stimulation of spinal cord injured patients has been developed. The stimulator is externally controlled and powered by a single encoded radio frequency carrier and has four independently controlled bipolar stimulation channels. It offers a wide range of reprogrammability and flexibility, and can be used in many neuromuscular electrical stimulation applications. The implant system is adaptable to patient's needs and to future developments in stimulation algorithms by reprogramming the stimulator. The stimulator is capable of generating a wide range of stimulation waveforms and stimulation patterns and therefore is very suitable for selective nerve stimulation techniques. The reliability of the implant has been increased by using a forward error detection and correction communication protocol and by designing the chip for structural testability based on scan test approach. Implemented testability scheme makes it possible to verify the complete functionality of the implant before and after implantation. The stimulators architecture is designed to be modular and therefore its different blocks can be reused as standard building blocks in the design and implementation of other neuromuscular prostheses. Design for low-power techniques have also been employed to reduce power consumption of the electronic circuitry.
1985-04-01
evaluation is predominantly based on the impressions he gets from the stimulation of his sensual receptors, i.e. visual, motional and auditorial cues. For...Exchanging of scientific and technical information; - Continuously stimulating advances in the aerospace sciences relevant to strengthening the...extented. International cooperation has always been stimulating . Strong technology transfer restrictions could result in a technical isolation with
Ermer, James C; Adeyi, Ben A; Pucci, Michael L
2010-12-01
Methylphenidate- and amfetamine-based stimulants are first-line pharmacotherapies for attention-deficit hyperactivity disorder, a common neurobehavioural disorder in children and adults. A number of long-acting stimulant formulations have been developed with the aim of providing once-daily dosing, employing various means to extend duration of action, including a transdermal delivery system, an osmotic-release oral system, capsules with a mixture of immediate- and delayed-release beads, and prodrug technology. Coefficients of variance of pharmacokinetic measures can estimate the levels of pharmacokinetic variability based on the measurable variance between different individuals receiving the same dose of stimulant (interindividual variability) and within the same individual over multiple administrations (intraindividual variability). Differences in formulation clearly impact pharmacokinetic profiles. Many medications exhibit wide interindividual variability in clinical response. Stimulants with low levels of inter- and intraindividual variability may be better suited to provide consistent levels of medication to patients. The pharmacokinetic profile of stimulants using pH-dependent bead technology can vary depending on food consumption or concomitant administration of medications that alter gastric pH. While delivery of methylphenidate with the transdermal delivery system would be unaffected by gastrointestinal factors, intersubject variability is nonetheless substantial. Unlike the beaded formulations and, to some extent (when considering total exposure) the osmotic-release formulation, systemic exposure to amfetamine with the prodrug stimulant lisdexamfetamine dimesylate appears largely unaffected by such factors, likely owing to its dependence on systemic enzymatic cleavage of the precursor molecule, which occurs primarily in the blood involving red blood cells. The high capacity but as yet unidentified enzymatic system for conversion of lisdexamfetamine dimesylate may contribute to its consistent pharmacokinetic profile. The reasons underlying observed differential responses to stimulants are likely to be multifactorial, including pharmacodynamic factors. While the use of stimulants with low inter- and intrapatient pharmacokinetic variability does not obviate the need to titrate stimulant doses, stimulants with low intraindividual variation in pharmacokinetic parameters may reduce the likelihood of patients falling into subtherapeutic drug concentrations or reaching drug concentrations at which the risk of adverse events increases. As such, clinicians are urged both to adjust stimulant doses based on therapeutic response and the risk for adverse events and to monitor patients for potential causes of pharmacokinetic variability.
Cohlen, B J
2009-01-01
World-wide, intrauterine insemination (IUI) is still one of the most applied techniques to enhance the probability of conception in couples with longstanding subfertility. The outcome of this treatment option depends on many confounding factors. One of the confounding factors receiving little attention is the quality of the luteal phase. From IVF studies, it is known that ovarian stimulation causes luteal phase deficiency. Based on the best available evidence, this short review summarizes the indications for mild ovarian stimulation combined with IUI and the optimal stimulation programme. While it has been established that stimulated IVF/intracytoplasmic sperm injection cycles have deficient luteal phases, the question remains whether the quality of the luteal phase when only two or three corpora lutea are present (as is the case in stimulated IUI cycles) is impaired as well. There are too few large non-IVF trials studying luteal phase quality to answer this question. Recently a randomized trial has been published that investigated luteal phase support in an IUI programme. This study is discussed in detail. It is recommended to apply luteal phase support in stimulated IUI cycles only when proven costeffective. Further trials are mandatory to investigate both endometrial and hormonal profile changes in the luteal phase after mild ovarian stimulation, and the cost-effectiveness of luteal support in IUI programmes.
NASA Astrophysics Data System (ADS)
Zhou, Yu-Xuan; Wang, Hai-Peng; Bao, Xue-Liang; Lü, Xiao-Ying; Wang, Zhi-Gong
2016-02-01
Objective. Surface electromyography (sEMG) is often used as a control signal in neuromuscular electrical stimulation (NMES) systems to enhance the voluntary control and proprioceptive sensory feedback of paralyzed patients. Most sEMG-controlled NMES systems use the envelope of the sEMG signal to modulate the stimulation intensity (current amplitude or pulse width) with a constant frequency. The aims of this study were to develop a strategy that co-modulates frequency and pulse width based on features of the sEMG signal and to investigate the torque-reproduction performance and the level of fatigue resistance achieved with our strategy. Approach. We examined the relationships between wrist torque and two stimulation parameters (frequency and pulse width) and between wrist torque and two sEMG time-domain features (mean absolute value (MAV) and number of slope sign changes (NSS)) in eight healthy volunteers. By using wrist torque as an intermediate variable, customized and generalized transfer functions were constructed to convert the two features of the sEMG signal into the two stimulation parameters, thereby establishing a MAV/NSS dual-coding (MNDC) algorithm. Wrist torque reproduction performance was assessed by comparing the torque generated by the algorithms with that originally recorded during voluntary contractions. Muscle fatigue was assessed by measuring the decline percentage of the peak torque and by comparing the torque time integral of the response to test stimulation trains before and after fatigue sessions. Main Results. The MNDC approach could produce a wrist torque that closely matched the voluntary wrist torque. In addition, a smaller decay in the wrist torque was observed after the MNDC-coded fatigue stimulation was applied than after stimulation using pulse-width modulation alone. Significance. Compared with pulse-width modulation stimulation strategies that are based on sEMG detection, the MNDC strategy is more effective for both voluntary muscle force reproduction and muscle fatigue reduction.
Sun, Li; Yeh, Judy; Xie, Zhuojun; Kuang, Mei; Damaser, Margot S; Zutshi, Massarat
2016-05-01
We have explored cell-based therapy to aid anal sphincter repair, but a conditioning injury is required to direct stem cells to the site of injury because symptoms usually manifest at a time remote from injury. We aimed to investigate the effect of local electrical stimulation followed by mesenchymal stem cell delivery on anal sphincter regeneration at a time remote from injury. With the use of a rat model, electrical stimulation parameters and cell delivery route were selected based on in vivo cytokine expression and luciferase-labeled cell imaging of the anal sphincter complex. Three weeks after a partial anal sphincter excision, rats were randomly allocated to 4 groups based on different local interventions: no treatment, daily electrical stimulation for 3 days, daily stimulation for 3 days followed by stem cell injection on the third day, and daily electrical stimulation followed by stem cell injection on the first and third days. Histology-assessed anatomy and anal manometry evaluated physiology 4 weeks after intervention. The electrical stimulation parameters that significantly upregulated gene expression of homing cytokines also achieved mesenchymal stem cell retention when injected directly in the anal sphincter complex in comparison with intravascular and intraperitoneal injections. Four weeks after intervention, there was significantly more new muscle in the area of injury and significantly improved anal resting pressure in the group that received daily electrical stimulation for 3 days followed by a single injection of 1 million stem cells on the third day at the site of injury. This was a pilot study and therefore was not powered for functional outcome. In this rat injury model with optimized parameters, electrical stimulation with a single local mesenchymal stem cell injection administered 3 weeks after injury significantly improved both new muscle formation in the area of injury and anal sphincter pressures.
2015-01-01
Electrical stimulation is used in order to restore nerve mediated functions in patients with neurological disorders, but its applicability is constrained by the invasiveness of the systems required to perform it. As an alternative to implantable systems consisting of central stimulation units wired to the stimulation electrodes, networks of wireless microstimulators have been devised for fine movement restoration. Miniaturization of these microstimulators is currently hampered by the available methods for powering them. Previously, we have proposed and demonstrated a heterodox electrical stimulation method based on electronic rectification of high frequency current bursts. These bursts can be delivered through textile electrodes on the skin. This approach has the potential to result in an unprecedented level of miniaturization as no bulky parts such as coils or batteries are included in the implant. We envision microstimulators designs based on application-specific integrated circuits (ASICs) that will be flexible, thread-like (diameters < 0.5 mm) and not only with controlled stimulation capabilities but also with sensing capabilities for artificial proprioception. We in vivo demonstrate that neuroprostheses composed of addressable microstimulators based on this electrical stimulation method are feasible and can perform controlled charge-balanced electrical stimulation of muscles. We developed miniature external circuit prototypes connected to two bipolar probes that were percutaneously implanted in agonist and antagonist muscles of the hindlimb of an anesthetized rabbit. The electronic implant architecture was able to decode commands that were amplitude modulated on the high frequency (1 MHz) auxiliary current bursts. The devices were capable of independently stimulating the target tissues, accomplishing controlled dorsiflexion and plantarflexion joint movements. In addition, we numerically show that the high frequency current bursts comply with safety standards both in terms of tissue heating and unwanted electro-stimulation. We demonstrate that addressable microstimulators powered by rectification of epidermically applied currents are feasible. PMID:26147771
Becerra-Fajardo, Laura; Ivorra, Antoni
2015-01-01
Electrical stimulation is used in order to restore nerve mediated functions in patients with neurological disorders, but its applicability is constrained by the invasiveness of the systems required to perform it. As an alternative to implantable systems consisting of central stimulation units wired to the stimulation electrodes, networks of wireless microstimulators have been devised for fine movement restoration. Miniaturization of these microstimulators is currently hampered by the available methods for powering them. Previously, we have proposed and demonstrated a heterodox electrical stimulation method based on electronic rectification of high frequency current bursts. These bursts can be delivered through textile electrodes on the skin. This approach has the potential to result in an unprecedented level of miniaturization as no bulky parts such as coils or batteries are included in the implant. We envision microstimulators designs based on application-specific integrated circuits (ASICs) that will be flexible, thread-like (diameters < 0.5 mm) and not only with controlled stimulation capabilities but also with sensing capabilities for artificial proprioception. We in vivo demonstrate that neuroprostheses composed of addressable microstimulators based on this electrical stimulation method are feasible and can perform controlled charge-balanced electrical stimulation of muscles. We developed miniature external circuit prototypes connected to two bipolar probes that were percutaneously implanted in agonist and antagonist muscles of the hindlimb of an anesthetized rabbit. The electronic implant architecture was able to decode commands that were amplitude modulated on the high frequency (1 MHz) auxiliary current bursts. The devices were capable of independently stimulating the target tissues, accomplishing controlled dorsiflexion and plantarflexion joint movements. In addition, we numerically show that the high frequency current bursts comply with safety standards both in terms of tissue heating and unwanted electro-stimulation. We demonstrate that addressable microstimulators powered by rectification of epidermically applied currents are feasible.
A modular, closed-loop platform for intracranial stimulation in people with neurological disorders.
Sarma, Anish A; Crocker, Britni; Cash, Sydney S; Truccolo, Wilson
2016-08-01
Neuromodulation systems based on electrical stimulation can be used to investigate, probe, and potentially treat a range of neurological disorders. The effects of ongoing neural state and dynamics on stimulation response, and of stimulation parameters on neural state, have broad implications for the development of closed-loop neuro-modulation approaches. We describe the development of a modular, low-latency platform for pre-clinical, closed-loop neuromodulation studies with human participants. We illustrate the uses of the platform in a stimulation case study with a person with epilepsy undergoing neuro-monitoring prior to resective surgery. We demonstrate the efficacy of the system by tracking interictal epileptiform discharges in the local field potential to trigger intracranial electrical stimulation, and show that the response to stimulation depends on the neural state.
ERIC Educational Resources Information Center
Vaino, Katrin; Holbrook, Jack; Rannikmae, Miia
2012-01-01
This paper introduces a research project in which five chemistry teachers, working in cooperation with university researchers, implemented a new teaching approach using context-based modules specially designed to stimulate the intrinsic motivation of students. The intention was to induce change in chemistry teachers' teaching approach from more…
Glasner-Edwards, Suzette; Mooney, Larissa J; Ang, Alfonso; Garneau, Hélène Chokron; Hartwell, Emily; Brecht, Mary-Lynn; Rawson, Richard A
2017-02-01
In light of the known associations between stress, negative affect, and relapse, mindfulness strategies hold promise as a means of reducing relapse susceptibility. In a pilot randomized clinical trial, we evaluated the effects of Mindfulness Based Relapse Prevention (MBRP), relative to a health education control condition (HE) among stimulant dependent adults receiving contingency management. All participants received a 12-week contingency management (CM) intervention. Following a 4-week CM-only lead in phase, participants were randomly assigned to concurrently receive MBRP (n=31) or HE (n=32). Stimulant dependent adults age 18 and over. A university based clinical research center. The primary outcomes were stimulant use, measured by urine drug screens weekly during the intervention and at 1-month post-treatment, negative affect, measured by the Beck Depression Inventory and Beck Anxiety Inventory, and psychiatric severity, measured by the Addiction Severity Index. Medium effect sizes favoring MBRP were observed for negative affect and overall psychiatric severity outcomes. Depression severity changed differentially over time as a function of group, with MBRP participants reporting greater reductions through follow-up (p=0.03; Effect Size=0.58). Likewise, the MBRP group evidenced greater declines in psychiatric severity, (p=0.01; Effect Size=0.61 at follow-up). Among those with depressive and anxiety disorders, MBRP was associated with lower odds of stimulant use relative to the control condition (Odds Ratio= 0.78, p=0.03 and OR=0.68, p=0.04). MBRP effectively reduces negative affect and psychiatric impairment, and is particularly effective in reducing stimulant use among stimulant dependent adults with mood and anxiety disorders.
Effects of stimulant medication under varied motivational operations.
Mace, F Charles; Prager, Kevin L; Thomas, Karen; Kochy, Jane; Dyer, Tim J; Perry, Lora; Pritchard, Duncan
2009-01-01
We evaluated the evocative effects of four conditions (high- and low-preference activities, low and divided attention) and stimulant medication on the behavior of a 16-year-old boy with attention deficit hyperactivity disorder and moderate mental retardation. All behavior (activity engagement, activity changes, inappropriate touching, rude behaviors, and physical aggression) improved with stimulant medication in most conditions, but undesirable behaviors were not reduced to acceptable levels in all conditions. This finding suggests that stimulant medication may be a valuable adjunct to function-based interventions.
Do prescription stimulants increase the risk of adverse cardiovascular events?: A systematic review
2012-01-01
Background There is increasing concern that prescription stimulants may be associated with adverse cardiovascular events such as stroke, myocardial infarction, and sudden death. Public health concerns are amplified by increasing use of prescription stimulants among adults. Methods The objective of this study was to conduct a systematic review of the evidence of an association between prescription stimulant use and adverse cardiovascular outcomes. PUBMED, MEDLINE, EMBASE and Google Scholar searches were conducted using key words related to these topics (MESH): ADHD; Adults; Amphetamine; Amphetamines; Arrhythmias, Cardiac; Cardiovascular Diseases; Cardiovascular System; Central Nervous Stimulants; Cerebrovascular; Cohort Studies; Case–control Studies; Death; Death, Sudden, Cardiac; Dextroamphetamine; Drug Toxicity; Methamphetamine; Methylphenidate; Myocardial Infarction; Stimulant; Stroke; Safety. Eligible studies were population-based studies of children, adolescents, or adults using prescription stimulant use as the independent variable and a hard cardiovascular outcome as the dependent variable. Results Ten population-based observational studies which evaluated prescription stimulant use with cardiovascular outcomes were reviewed. Six out of seven studies in children and adolescents did not show an association between stimulant use and adverse cardiovascular outcomes. In contrast, two out of three studies in adults found an association. Conclusions Findings of an association between prescription stimulant use and adverse cardiovascular outcomes are mixed. Studies of children and adolescents suggest that statistical power is limited in available study populations, and the absolute risk of an event is low. More suggestive of a safety signal, studies of adults found an increased risk for transient ischemic attack and sudden death/ventricular arrhythmia. Interpretation was limited due to differences in population, cardiovascular outcome selection/ascertainment, and methodology. Accounting for confounding and selection biases in these studies is of particular concern. Future studies should address this and other methodological issues. PMID:22682429
Bayesian neural adjustment of inhibitory control predicts emergence of problem stimulant use.
Harlé, Katia M; Stewart, Jennifer L; Zhang, Shunan; Tapert, Susan F; Yu, Angela J; Paulus, Martin P
2015-11-01
Bayesian ideal observer models quantify individuals' context- and experience-dependent beliefs and expectations about their environment, which provides a powerful approach (i) to link basic behavioural mechanisms to neural processing; and (ii) to generate clinical predictors for patient populations. Here, we focus on (ii) and determine whether individual differences in the neural representation of the need to stop in an inhibitory task can predict the development of problem use (i.e. abuse or dependence) in individuals experimenting with stimulants. One hundred and fifty-seven non-dependent occasional stimulant users, aged 18-24, completed a stop-signal task while undergoing functional magnetic resonance imaging. These individuals were prospectively followed for 3 years and evaluated for stimulant use and abuse/dependence symptoms. At follow-up, 38 occasional stimulant users met criteria for a stimulant use disorder (problem stimulant users), while 50 had discontinued use (desisted stimulant users). We found that those individuals who showed greater neural responses associated with Bayesian prediction errors, i.e. the difference between actual and expected need to stop on a given trial, in right medial prefrontal cortex/anterior cingulate cortex, caudate, anterior insula, and thalamus were more likely to exhibit problem use 3 years later. Importantly, these computationally based neural predictors outperformed clinical measures and non-model based neural variables in predicting clinical status. In conclusion, young adults who show exaggerated brain processing underlying whether to 'stop' or to 'go' are more likely to develop stimulant abuse. Thus, Bayesian cognitive models provide both a computational explanation and potential predictive biomarkers of belief processing deficits in individuals at risk for stimulant addiction. © The Author (2015). Published by Oxford University Press on behalf of the Guarantors of Brain. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Monitoring of ionospheric turbulence spatial features by SEE diagnostic tools
NASA Astrophysics Data System (ADS)
Sergeev, E. N.; Boiko, G. N.; Shvarts, M. M.; Grach, S. M.; Kotov, P. V.
Spatial features of HF pumped ionospheric F-region are investigated experimentally at the SURA facility by means of the stimulated electromagnetic emission (SEE). SEE, recall, appears as a result of conversion (or scattering) of HF pump-driven plasma waves off the geomagnetic field aligned electron density irregularities (striations). A specially designed pumping scheme was elaborated to study an influence of the perturbations of the electron density and temperature, created by powerful pump wave at frequency f_h and occupying quite extended altitude range (range-I), on spectral and temporal evolution of the diagnostic SEE (DSEE) generated by a weak continuous or pulse diagnostic wave at a frequency f_d in an altitude range-II, spatially shifted from the centre of the range-I. New two-channel digital receiver allowed to analyze the SEE from both ranges (around both frequencies f_h and f_d) simultaneously. A combination of the SEE diagnostics and computer simulations allowed to study:% (a) dependences of striation spectrum and dynamics on the frequency shift |f_h-f_d| (which can be easily translated to the altitude displacement), powers of the pump and diagnostic waves, offsets of the frequencies f_h and f_d from electron gyroharmonics, and on the daily conditions. It is found that a slow (time scale of 1--10 s) dynamics of DSEE, namely, characteristics of its slow overshoot and undershoot effects are determined by the spectral shape and intensity of the striations at, respectively, the development and relaxation stages. It is shown that the striation spectrum flattens in meter scale range for f_h between 3th and 4th gyroharmonics in comparison with larger f_h, in the centre of the range-I in comparison with its periphery, that the range-I extension increases with its altitude and with a transition from day to night conditions;% (b) an influence of the powerful pumping on ``diagnostic'' HF plasma wave evolution by measurements of growth and decay times of the DSEE. It is found that a shape and fast (time scale of 1--10 ms) dynamics of the DSEE spectrum is determined by efficiency of interaction between different HF modes (determined, particularly, by f_d offset from a gyroharmonic), but not by striation characteristics. Besides, during the powerful pumping the DSEE decay rates always exceed the collision values observed for purely diagnostic schedule at nighttime conditions.% The work was supported by INTAS grant 03-515583, RFBR grants 04-02-17544 and 03-02-16309, grant E02-3.2-36 of Education Ministry of Russian Federation.
Germany, Enrique I; Pino, Esteban J; Aqueveque, Pablo E
2016-08-01
This paper presents the development of a myoelectric prosthetic hand based on a 3D printed model. A myoelectric control strategy based on artificial neural networks is implemented on a microcontroller for online position estimation. Position estimation performance achieves a correlation index of 0.78. Also a study involving transcutaneous electrical stimulation was performed to provide tactile feedback. A series of stimulations with controlled parameters were tested on five able-body subjects. A single channel stimulator was used, positioning the electrodes 8 cm on the wrist over the ulnar and median nerve. Controlling stimulation parameters such as intensity, frequency and pulse width, the subjects were capable of distinguishing different sensations over the palm of the hand. Three main sensations where achieved: tickling, pressure and pain. Tickling and pressure were discretized into low, moderate and high according to the magnitude of the feeling. The parameters at which each sensation was obtained are further discussed in this paper.
How to personalize ovarian stimulation in clinical practice.
Sighinolfi, Giovanna; Grisendi, Valentina; La Marca, Antonio
2017-09-01
Controlled ovarian stimulation (COS) in in vitro fertilization (IVF) cycles is the starting point from which couple's prognosis depends. Individualization in follicle-stimulating hormone (FSH) starting dose and protocol used is based on ovarian response prediction, which depends on ovarian reserve. Anti-Müllerian hormone levels and the antral follicle count are considered the most accurate and reliable markers of ovarian reserve. A literature search was performed for studies that addressed the ability of ovarian reserve markers to predict poor and high ovarian response in assisted reproductive technology cycles. According to the predicted response to ovarian stimulation (poor- normal- or high- response), it is possible to counsel couples before treatment about the prognosis, and also to individualize ovarian stimulation protocols, choosing among GnRH-agonists or antagonists for endogenous FSH suppression, and the FSH starting dose in order to decrease the risk of cycle cancellation and ovarian hyperstimulation syndrome. In this review we discuss how to choose the best COS therapy, based on ovarian reserve markers, in order to enhance chances in IVF.
Zhou, J. A.; Woo, S. J.; Park, S. I.; Kim, E. T.; Seo, J. M.; Chung, H.; Kim, S. J.
2008-01-01
This article reports on a retinal stimulation system for long-term use in animal electrical stimulation experiments. The presented system consisted of an implantable stimulator which provided continuous electrical stimulation, and an external component which provided preset stimulation patterns and power to the implanted stimulator via a paired radio frequency (RF) coil. A rechargeable internal battery and a parameter memory component were introduced to the implanted retinal stimulator. As a result, the external component was not necessary during the stimulation mode. The inductive coil pair was used to pass the parameter data and to recharge the battery. A switch circuit was used to separate the stimulation mode from the battery recharging mode. The implantable stimulator was implemented with IC chips and the electronics, except for the stimulation electrodes, were hermetically packaged in a biocompatible metal case. A polyimide-based gold electrode array was used. Surgical implantation into rabbits was performed to verify the functionality and safety of this newly designed system. The electrodes were implanted in the suprachoroidal space. Evoked cortical potentials were recorded during electrical stimulation of the retina. Long-term follow-up using OCT showed no chorioretinal abnormality after implantation of the electrodes. PMID:18317521
How stimulation speed affects Event-Related Potentials and BCI performance.
Höhne, Johannes; Tangermann, Michael
2012-01-01
In most paradigms for Brain-Computer Interfaces (BCIs) that are based on Event-Related Potentials (ERPs), stimuli are presented with a pre-defined and constant speed. In order to boost BCI performance by optimizing the parameters of stimulation, this offline study investigates the impact of the stimulus onset asynchrony (SOA) on ERPs and the resulting classification accuracy. The SOA is defined as the time between the onsets of two consecutive stimuli, which represents a measure for stimulation speed. A simple auditory oddball paradigm was tested in 14 SOA conditions with a SOA between 50 ms and 1000 ms. Based on an offline ERP analysis, the BCI performance (quantified by the Information Transfer Rate, ITR in bits/min) was simulated. A great variability in the simulated BCI performance was observed within subjects (N=11). This indicates a potential increase in BCI performance (≥ 1.6 bits/min) for ERP-based paradigms, if the stimulation speed is specified for each user individually.
Virtual reality adaptive stimulation of limbic networks in the mental readiness training.
Cosić, Kresimir; Popović, Sinisa; Kostović, Ivica; Judas, Milos
2010-01-01
A significant proportion of severe psychological problems in recent large-scale peacekeeping operations underscores the importance of effective methods for strengthening the stress resilience. Virtual reality (VR) adaptive stimulation, based on the estimation of the participant's emotional state from physiological signals, may enhance the mental readiness training (MRT). Understanding neurobiological mechanisms by which the MRT based on VR adaptive stimulation can affect the resilience to stress is important for practical application in the stress resilience management. After the delivery of a traumatic audio-visual stimulus in the VR, the cascade of events occurs in the brain, which evokes various physiological manifestations. In addition to the "limbic" emotional and visceral brain circuitry, other large-scale sensory, cognitive, and memory brain networks participate with less known impact in this physiological response. The MRT based on VR adaptive stimulation may strengthen the stress resilience through targeted brain-body interactions. Integrated interdisciplinary efforts, which would integrate the brain imaging and the proposed approach, may contribute to clarifying the neurobiological foundation of the resilience to stress.
Arfin, Scott K; Sarpeshkar, Rahul
2012-02-01
In this paper, we present a novel energy-efficient electrode stimulator. Our stimulator uses inductive storage and recycling of energy in a dynamic power supply. This supply drives an electrode in an adiabatic fashion such that energy consumption is minimized. It also utilizes a shunt current-sensor to monitor and regulate the current through the electrode via feedback, thus enabling flexible and safe stimulation. Since there are no explicit current sources or current limiters, wasteful energy dissipation across such elements is naturally avoided. The dynamic power supply allows efficient transfer of energy both to and from the electrode and is based on a DC-DC converter topology that we use in a bidirectional fashion in forward-buck or reverse-boost modes. In an exemplary electrode implementation intended for neural stimulation, we show how the stimulator combines the efficiency of voltage control and the safety and accuracy of current control in a single low-power integrated-circuit built in a standard .35 μm CMOS process. This stimulator achieves a 2x-3x reduction in energy consumption as compared to a conventional current-source-based stimulator operating from a fixed power supply. We perform a theoretical analysis of the energy efficiency that is in accord with experimental measurements. This theoretical analysis reveals that further improvements in energy efficiency may be achievable with better implementations in the future. Our electrode stimulator could be widely useful for neural, cardiac, retinal, cochlear, muscular and other biomedical implants where low power operation is important.
Criminality Among Rural Stimulant Users in the United States
Leukefeld, Carl; Staton-Tindall, Michele; Duvall, Jamieson; Garrity, Thomas; Stoops, William; Falck, Russel; Wang, Jichuan; Carlson, Robert; Sexton, Rocky; Wright, Patricia; Booth, Brenda
2009-01-01
Despite the increase in media attention on “meth cooking” in rural areas of the United States, little is known about rural stimulant use, particularly the criminality associated with stimulant use. Data were collected from community stimulant users in rural Ohio, Arkansas, and Kentucky (N=709). Findings from three logistic regression models indicate that younger stimulant users (x =32.55, SD = 10.35), those with more convictions, and those who used crack frequently were significantly more likely to have been arrested for committing a substance-related crime, a property crime, or another crime in the 6-months before entering the study. Implications include the need for longitudinal studies to further understand rural stimulant use as well as increasing community and corrections-based drug abuse prevention and treatment interventions for stimulant users who live in rural areas. PMID:21686091
Criminality Among Rural Stimulant Users in the United States.
Oser, Carrie; Leukefeld, Carl; Staton-Tindall, Michele; Duvall, Jamieson; Garrity, Thomas; Stoops, William; Falck, Russel; Wang, Jichuan; Carlson, Robert; Sexton, Rocky; Wright, Patricia; Booth, Brenda
2011-07-01
Despite the increase in media attention on "meth cooking" in rural areas of the United States, little is known about rural stimulant use, particularly the criminality associated with stimulant use. Data were collected from community stimulant users in rural Ohio, Arkansas, and Kentucky (N=709). Findings from three logistic regression models indicate that younger stimulant users (x =32.55, SD = 10.35), those with more convictions, and those who used crack frequently were significantly more likely to have been arrested for committing a substance-related crime, a property crime, or another crime in the 6-months before entering the study. Implications include the need for longitudinal studies to further understand rural stimulant use as well as increasing community and corrections-based drug abuse prevention and treatment interventions for stimulant users who live in rural areas.
Miyoshi, S; Sakajiri, M; Ifukube, T; Matsushima, J
1997-01-01
We have proposed the Tripolar Electrode Stimulation Method (TESM) which may enable us to narrow the stimulation region and to move continuously the stimulation site for the cochlear implants. We evaluated whether or not TESM works according to a theory based on numerical analysis using the auditory nerve fiber model. In this simulation, the sum of the excited model fibers were compared with the compound actions potentials obtained from animal experiments. As a result, this experiment showed that TESM could narrow a stimulation region by controlling the sum of the currents emitted from the electrodes on both sides, and continuously move a stimulation site by changing the ratio of the currents emitted from the electrodes on both sides.
ERIC Educational Resources Information Center
Lancioni, Giulio E.; Bellini, Domenico; Oliva, Doretta; Singh, Nirbhay N.; O'Reilly, Mark F.; Sigafoos, Jeff; Lang, Russell
2012-01-01
Background: A camera-based microswitch technology was recently developed to monitor small facial responses of persons with multiple disabilities and allow those responses to control environmental stimulation. This study assessed such a technology with 2 new participants using slight variations of previous responses. Method: The technology involved…
ERIC Educational Resources Information Center
Zhyzhko, Olena
2017-01-01
This article presents the results of scientific-pedagogical research, which consisted in identifying, what are the best strategies of stimulation of students' interest in the teaching by competency-based approach studying the works of Latin American scientists. With support in the pedagogic-comparative study the author has found out that in the…
Fiber-optic two-photon optogenetic stimulation.
Dhakal, K; Gu, L; Black, B; Mohanty, S K
2013-06-01
Optogenetic stimulation of genetically targeted cells is proving to be a powerful tool in the study of cellular systems, both in vitro and in vivo. However, most opsins are activated in the visible spectrum, where significant absorption and scattering of stimulating light occurs, leading to low penetration depth and less precise stimulation. Since we first (to the best of our knowledge) demonstrated two-photon optogenetic stimulation (TPOS), it has gained considerable interest in the probing of cellular circuitry by precise spatial modulation. However, all existing methods use microscope objectives and complex scanning beam geometries. Here, we report a nonscanning method based on multimode fiber to accomplish fiber-optic TPOS of cells.
Hauptmann, C; Roulet, J-C; Niederhauser, J J; Döll, W; Kirlangic, M E; Lysyansky, B; Krachkovskyi, V; Bhatti, M A; Barnikol, U B; Sasse, L; Bührle, C P; Speckmann, E-J; Götz, M; Sturm, V; Freund, H-J; Schnell, U; Tass, P A
2009-12-01
In the past decade deep brain stimulation (DBS)-the application of electrical stimulation to specific target structures via implanted depth electrodes-has become the standard treatment for medically refractory Parkinson's disease and essential tremor. These diseases are characterized by pathological synchronized neuronal activity in particular brain areas. We present an external trial DBS device capable of administering effectively desynchronizing stimulation techniques developed with methods from nonlinear dynamics and statistical physics according to a model-based approach. These techniques exploit either stochastic phase resetting principles or complex delayed-feedback mechanisms. We explain how these methods are implemented into a safe and user-friendly device.
Remote control of microcontroller-based infant stimulating system.
Burunkaya, M; Güler, I
2000-04-01
In this paper, a remote-controlled and microcontroller-based cradle is designed and constructed. This system is also called Remote Control of Microcontroller-Based Infant Stimulation System or the RECOMBIS System. Cradle is an infant stimulating system that provides relaxation and sleeping for the baby. RECOMBIS system is designed for healthy full-term newborns to provide safe infant care and provide relaxation and sleeping for the baby. A microcontroller-based electronic circuit was designed and implemented for RECOMBIS system. Electromagnets were controlled by 8-bit PIC16F84 microcontroller, which is programmed using MPASM package. The system works by entering preset values from the keyboard, or pulse code modulated radio frequency remote control system. The control of the system and the motion range were tested. The test results showed that the system provided a good performance.
Nipple/Breast stimulation and sexual arousal in young men and women.
Levin, Roy; Meston, Cindy
2006-05-01
The role of nipple/breast stimulation in influencing sexual arousal in men and women during lovemaking has only been the subject of opinion-based comment rather than evidence-based study. No attempt to question people about such sexual behavior has ever been undertaken. The study was designed to ascertain the effects of nipple/breast manipulation in young men and women on their sexual arousal. A short questionnaire about nipple/breast stimulation during sexual activity was administered to 301 (148 men; 153 women) sexually experienced undergraduates (age range 17-29 years, 95% between 18 and 22). Replies to questions in questionnaire. The major findings in regard to the women were that 81.5% reported that stimulation of their nipples/breasts caused or enhanced their sexual arousal, 78.2% agreed that when sexually aroused such manipulation increased their arousal, 59.1% had asked to have their nipples stimulated during lovemaking, and only 7.2% found that the manipulation decreased their arousal. In regard to the men, 51.7% reported that nipple stimulation caused or enhanced their sexual arousal, 39% agreed that when sexually aroused such manipulation increased their arousal, only 17.1% had asked to have their nipples stimulated, and only 7.5% found that such stimulation decreased their arousal. Manipulation of the nipples/breasts causes or enhances sexual arousal in approximately 82% of young women and 52% of young men with only 7-8% reporting that it decreased their arousal.
ERIC Educational Resources Information Center
Panerai, Simonetta; Tasca, Domenica; Lanuzza, Bartolo; Trubia, Grazia; Ferri, Raffaele; Musso, Sabrina; Alagona, Giovanna; Di Guardo, Giuseppe; Barone, Concetta; Gaglione, Maria P.; Elia, Maurizio
2014-01-01
This report, based on four studies with children with low-functioning autism, aimed at evaluating the effects of repetitive transcranial magnetic stimulation delivered on the left and right premotor cortices on eye-hand integration tasks; defining the long-lasting effects of high-frequency repetitive transcranial magnetic stimulation; and…
NASA Astrophysics Data System (ADS)
DePaoli, Damon T.; Lapointe, Nicolas; Goetz, Laurent; Parent, Martin; Prudhomme, Michel; Cantin, Léo.; Galstian, Tigran; Messaddeq, Younès.; Côté, Daniel C.
2016-03-01
Deep brain stimulation's effectiveness relies on the ability of the stimulating electrode to be properly placed within a specific target area of the brain. Optical guidance techniques that can increase the accuracy of the procedure, without causing any additional harm, are therefore of great interest. We have designed a cheap optical fiber-based device that is small enough to be placed within commercially available DBS stimulating electrodes' hollow cores and that is capable of sensing biological information from the surrounding tissue, using low power white light. With this probe we have shown the ability to distinguish white and grey matter as well as blood vessels, in vitro, in human brain samples and in vivo, in rats. We have also repeated the in vitro procedure with the probe inserted in a DBS stimulating electrode and found the results were in good agreement. We are currently validating a second fiber optic device, with micro-optical components, that will result in label free, molecular level sensing capabilities, using CARS spectroscopy. The final objective will be to use this data in real time, during deep brain stimulation neurosurgery, to increase the safety and accuracy of the procedure.
Baumgarten, Clement; Zhao, Yulong; Sauleau, Paul; Malrain, Cecile; Jannin, Pierre; Haegelen, Claire
2016-04-01
Deep brain stimulation of the medial globus pallidus (GPm) is a surgical procedure for treating patients suffering from Parkinson's disease. Its therapeutic effect may be limited by the presence of pyramidal tract side effect (PTSE). PTSE is a contraction time-locked to the stimulation when the current spreading reaches the motor fibers of the pyramidal tract within the internal capsule. The objective of the study was to propose a preoperative predictive model of PTSE. A machine learning-based method called PyMAN (PTSE model based on artificial neural network) accounting for the current used in stimulation, the three-dimensional electrode coordinates and the angle of the trajectory, was designed to predict the occurrence of PTSE. Ten patients implanted in the GPm have been tested by a clinician to create a labeled dataset of the stimulation parameters that trigger PTSE. The kappa index value between the data predicted by PyMAN and the labeled data was 0.78. Further evaluation studies are desirable to confirm whether PyMAN could be a reliable tool for assisting the surgeon to prevent PTSE during the preoperative planning.
A Wireless Implantable Switched-Capacitor Based Optogenetic Stimulating System
Lee, Hyung-Min; Kwon, Ki-Yong; Li, Wen
2015-01-01
This paper presents a power-efficient implantable optogenetic interface using a wireless switched-capacitor based stimulating (SCS) system. The SCS efficiently charges storage capacitors directly from an inductive link and periodically discharges them into an array of micro-LEDs, providing high instantaneous power without affecting wireless link and system supply voltage. A custom-designed computer interface in LabVIEW environment wirelessly controls stimulation parameters through the inductive link, and an optrode array enables simultaneous neural recording along with optical stimulation. The 4-channel SCS system prototype has been implemented in a 0.35-μm CMOS process and combined with the optrode array. In vivo experiments involving light-induced local field potentials verified the efficacy of the SCS system. An implantable version of the SCS system with flexible hermetic sealing is under development for chronic experiments. PMID:25570099
Huang, Zonghao; Wang, Zhigong; Lv, Xiaoying; Zhou, Yuxuan; Wang, Haipeng; Zong, Sihao
2014-01-01
Hemiparesis is one of the most common consequences of stroke. Advanced rehabilitation techniques are essential for restoring motor function in hemiplegic patients. Functional electrical stimulation applied to the affected limb based on myoelectric signal from the unaffected limb is a promising therapy for hemiplegia. In this study, we developed a prototype system for evaluating this novel functional electrical stimulation-control strategy. Based on surface electromyography and a vector machine model, a self-administered, multi-movement, force-modulation functional electrical stimulation-prototype system for hemiplegia was implemented. This paper discusses the hardware design, the algorithm of the system, and key points of the self-oscillation-prone system. The experimental results demonstrate the feasibility of the prototype system for further clinical trials, which is being conducted to evaluate the efficacy of the proposed rehabilitation technique. PMID:25657728
Respiratory and Pulse Changes Due to Vestibular Stimulations in a Motion-Based Simulator.
Ilbasmis, Savas; Yildiz, Safak
2017-01-01
One of the mechanisms leading to spatial disorientation (SD) is overstimulation of the vestibular system by various aircraft maneuvers. The objective of this study was to observe respiratory rate and pulse changes during vestibular system stimulations with the help of two selected SD training profiles. The respiration and pulse rates of 15 subjects were recorded in response to 2 sequential SD training profiles on a motion-based simulator. The session started with a motionless instruction period (IP), continued with a Coriolis profile (CP) which stimulated the semicircular canals, and ended with a Dark Takeoff profile (DP) which stimulated the otolith organs. Recorded parameter means during profiles were statistically compared with IP mean values. The average age of all subjects was 23.67 ± 1.11. Mean CP respiratory rate (23.43 ± 3.21) was higher than mean IP respiratory rate (21.39 ± 4.27) and mean DP pulse rate (79.88 ± 10.39) was lower than mean IP pulse rate (84.76 ± 14.26) of the subjects. These differences were statistically significant. Data indicate that stimulation of the semicircular canals increased respiration rate while stimulation of the otoliths caused a reduction in pulse rate. This was considered to be a result of vestibulorespiratory reflex. Inputs from the vestibular otolith organs contribute to the control of blood pressure during movement and changes in posture. Predicting pulse and respiratory changes due to aerial maneuvers may be important for pilot safety during flight.Ilbasmis S, Yildiz S. Respiratory and pulse changes due to vestibular stimulations in a motion-based simulator. Aerosp Med Hum Perform. 2017; 88(1):48-51.
Mendez, Frances; Kozin, Elliott; Bases, Robert
2003-01-01
Base excision repair (BER) of damaged deoxyribonucleic acid (DNA) is a multistep process during which potentially lethal abasic sites temporarily exist. Repair of these lesions is greatly stimulated by heat shock protein 70 (Hsp70), which enhances strand incision and removal of the abasic sites by human apurinic-apyrimidinic endonuclease (HAP1). The resulting single-strand gaps must then be filled in. Here, we show that Hsp70 and its 48- and 43-kDa N-terminal domains greatly stimulated filling in the single-strand gaps by DNA polymerase β, a novel finding that extends the role of Hsps in DNA repair. Incorporation of deoxyguanosine monophosphate (dGMP) to fill in single-strand gaps in DNA phagemid pBKS by DNA polymerase β was stimulated by Hsp70. Truncated proteins derived from the C-terminus of Hsp70 as well as unrelated proteins were less effective, but proteins derived from the N-terminus of Hsp70 remained efficient stimulators of DNA polymerase β repair of DNA single-strand gaps. In agreement with these results, repair of a gap in a 30-bp oligonucleotide by polymerase β also was strongly stimulated by Hsp70 although not by a truncated protein from the C-terminus of Hsp70. Sealing of the repaired site in the oligonucleotide by human DNA ligase 1 was not specifically stimulated by Hsp-related proteins. Results presented here now implicate and extend the role of Hsp70 as a partner in the enzymatic repair of damaged DNA. The participation of Hsp70 jointly with base excision enzymes improves repair efficiency by mechanisms that are not yet understood. PMID:14627201
Janice Jimenez-Torres, G; Weinstein, Benjamin L; Walker, Cory R; Christopher Fowler, J; Ashford, Philippa; Borckardt, Jeffrey J; Madan, Alok
2017-03-01
Available treatments for chronic pain (CP) are modestly effective or associated with iatrogenic harm. Transcranial direct current stimulation (tDCS) is a non-invasive brain stimulation technique that may be an effective, adjunctive treatment to non-opioid therapies. In this randomized control trial (RCT), we compare adjunctive active versus sham tDCS among patients in a multimodal inpatient pain management program. The primary objectives of the RCT are to improve pain tolerance and subjective pain experience. Patients admitted to the Pain Management Program at The Menninger Clinic in Houston, Texas are eligible for this trial. Eighty-four participants will be randomized (1:1) into a single-blind, 2×12 (group×time) controlled trial. A battery-powered direct and constant current stimulator (Soterix Medical Inc. 2014) delivers anodal stimulation over the left dorsolateral prefrontal cortex (DLPFC) and cathodal stimulation over the right DLPFC. Active tDCS is applied by supplying a 2mA current for 20min/session over 10 sessions. Participants complete self-report and performance-based assessments on a weekly basis just prior to brain stimulation. Self-report assessments are collected via Chronic Pain Tracker version 3.6, an iPad interfaced application. The performance-based pain tolerance task is completed through the cold presser task. Interventions with cross-symptomatic therapeutic potential are absolutely essential in the context of CP, in which psychiatric comorbidity is the norm. Modalities that can be used in tandem with evidence-based, non-opioid therapies have the potential to have a synergistic effect, resulting in increased effectiveness of what have been modestly effective treatments to date. Copyright © 2017 Elsevier Inc. All rights reserved.
Transcranial Electric Stimulation for Precision Medicine: A Spatiomechanistic Framework
Yavari, Fatemeh; Nitsche, Michael A.; Ekhtiari, Hamed
2017-01-01
During recent years, non-invasive brain stimulation, including transcranial electrical stimulation (tES) in general, and transcranial direct current stimulation (tDCS) in particular, have created new hopes for treatment of neurological and psychiatric diseases. Despite promising primary results in some brain disorders, a more widespread application of tES is hindered by the unsolved question of determining optimum stimulation protocols to receive meaningful therapeutic effects. tES has a large parameter space including various montages and stimulation parameters. Moreover, inter- and intra-individual differences in responding to stimulation protocols have to be taken into account. These factors contribute to the complexity of selecting potentially effective protocols for each disorder, different clusters of each disorder, and even each single patient. Expanding knowledge in different dimensions of basic and clinical neuroscience could help researchers and clinicians to select potentially effective protocols based on tES modulatory mechanisms for future clinical studies. In this article, we propose a heuristic spatiomechanistic framework which contains nine levels to address tES effects on brain functions. Three levels refer to the spatial resolution (local, small-scale networks and large-scale networks) and three levels of tES modulatory effects based on its mechanisms of action (neurochemical, neuroelectrical and oscillatory modulations). At the group level, this framework could be helpful to enable an informed and systematic exploration of various possible protocols for targeting a brain disorder or its neuroscience-based clusters. Considering recent advances in exploration of neurodiversity at the individual level with different brain mapping technologies, the proposed framework might also be used in combination with personal data to design individualized protocols for tES in the context of precision medicine in the future. PMID:28450832
Stimulation-Based Control of Dynamic Brain Networks
Pasqualetti, Fabio; Gu, Shi; Cieslak, Matthew
2016-01-01
The ability to modulate brain states using targeted stimulation is increasingly being employed to treat neurological disorders and to enhance human performance. Despite the growing interest in brain stimulation as a form of neuromodulation, much remains unknown about the network-level impact of these focal perturbations. To study the system wide impact of regional stimulation, we employ a data-driven computational model of nonlinear brain dynamics to systematically explore the effects of targeted stimulation. Validating predictions from network control theory, we uncover the relationship between regional controllability and the focal versus global impact of stimulation, and we relate these findings to differences in the underlying network architecture. Finally, by mapping brain regions to cognitive systems, we observe that the default mode system imparts large global change despite being highly constrained by structural connectivity. This work forms an important step towards the development of personalized stimulation protocols for medical treatment or performance enhancement. PMID:27611328
The effect of cadence on the muscle-tendon mechanics of the gastrocnemius muscle during walking.
Brennan, S F; Cresswell, A G; Farris, D J; Lichtwark, G A
2017-03-01
Humans naturally select a cadence that minimizes metabolic cost at a constant walking velocity. The aim of this study was to examine the effects of cadence on the medial gastrocnemius (MG) muscle and tendon interaction, and examine how this might influence lower limb energetics. We hypothesized that cadences higher than preferred would increase MG fascicle shortening velocity because of the reduced stride time. Furthermore, we hypothesized that cadences lower than preferred would require greater MG fascicle shortening to achieve increased muscle work requirements. We measured lower limb kinematics and kinetics, surface electromyography of the triceps surae and MG fascicle length, via ultrasonography, during walking at a constant velocity at the participants' preferred cadence and offsets of ±10%, ±20%, and ±30%. There was a significant increase in MG fascicle shortening with decreased cadence. However, there was no increase in the MG fascicle shortening velocity at cadences higher than preferred. Cumulative MG muscle activation per minute was significantly increased at higher cadences. We conclude that low cadence walking requires more MG shortening work, while MG muscle and tendon function changes little for each stride at higher cadences, driving up cumulative activation costs due to the increase in steps per minute. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Effects of high loading by eccentric triceps surae training on Achilles tendon properties in humans.
Geremia, Jeam Marcel; Baroni, Bruno Manfredini; Bobbert, Maarten Frank; Bini, Rodrigo Rico; Lanferdini, Fabio Juner; Vaz, Marco Aurélio
2018-06-01
To document the magnitude and time course of human Achilles tendon adaptations (i.e. changes in tendon morphological and mechanical properties) during a 12-week high-load plantar flexion training program. Ultrasound was used to determine Achilles tendon cross-sectional area (CSA), length and elongation as a function of plantar flexion torque during voluntary plantar flexion. Tendon force-elongation and stress-strain relationships were determined before the start of training (pre-training) and after 4 (post-4), 8 (post-8) and 12 (post-12) training weeks. At the end of the training program, maximum isometric force had increased by 49% and tendon CSA by 17%, but tendon length, maximal tendon elongation and maximal strain were unchanged. Hence, tendon stiffness had increased by 82%, and so had Young's modulus, by 86%. Significant changes were first detected at post-4 in stiffness (51% increase) and Young's modulus (87% increase), and at post-8 in CSA (15% increase). Achilles tendon material properties already improved after 4 weeks of high-load training: stiffness increased while CSA remained unchanged. Tendon hypertrophy (increased CSA) was observed after 8 training weeks and contributed to a further increase in Achilles tendon stiffness, but tendon stiffness increases were mostly caused by adaptations in tissue properties.
Wolfram, Susann; Morse, Christopher I; Winwood, Keith L; Hodson-Tole, Emma; McEwan, Islay M
2018-01-01
The triceps surae primarily acts as plantarflexor of the ankle joint. However, the group also causes inversion and eversion at the subtalar joint. Despite this, the Achilles tendon moment arm is generally measured without considering the potential influence of inversion/eversion of the foot during plantarflexion. This study investigated the effect of foot inversion and eversion on the plantarflexion Achilles tendon moment arm. Achilles tendon moment arms were determined using the centre-of-rotation method in magnetic resonance images of the left ankle of 11 participants. The foot was positioned at 15° dorsiflexion, 0° or 15° plantarflexion using a Styrofoam wedge. In each of these positions, the foot was either 10° inverted, neutral or 10° everted using an additional Styrofoam wedge. Achilles tendon moment arm in neutral foot position was 47.93 ± 4.54 mm and did not differ significantly when the foot was positioned in 10° inversion and 10° eversion. Hence, inversion/eversion position of the foot may not considerably affect the length of the Achilles tendon moment arm. This information could be useful in musculoskeletal models of the human lower leg and foot and when estimating Achilles tendon forces during plantarflexion with the foot positioned in inversion or eversion.
Miyamoto, Naokazu; Hirata, Kosuke; Miyamoto-Mikami, Eri; Yasuda, Osamu; Kanehisa, Hiroaki
2018-05-29
Joint range of motion (ROM) is an important parameter for athletic performance and muscular injury risk. Nonetheless, a complete description of muscular factors influencing ROM among individuals and between men and women is lacking. We examined whether passive muscle stiffness (evaluated by angle-specific muscle shear modulus), tolerance to muscle stretch (evaluated by muscle shear modulus at end-ROM), and muscle slack angle of the triceps surae are associated with the individual variability and sex difference in dorsiflexion ROM, using ultrasound shear wave elastography. For men, ROM was negatively correlated to passive muscle stiffness of the medial and lateral gastrocnemius in a tensioned state and positively to tolerance to muscle stretch in the medial gastrocnemius. For women, ROM was only positively correlated to tolerance to muscle stretch in all muscles but not correlated to passive muscle stiffness. Muscle slack angle was not correlated to ROM in men and women. Significant sex differences were observed only for dorsiflexion ROM and passive muscle stiffness in a tensioned state. These findings suggest that muscular factors associated with ROM are different between men and women. Furthermore, the sex difference in dorsiflexion ROM might be attributed partly to that in passive muscle stiffness of plantar flexors.
Romano, Emanuela; Rossi, Marco; Ratzinger, Gudrun; de Cos, Maria-Angeles; Chung, David J.; Panageas, Katherine S.; Wolchok, Jedd D.; Houghton, Alan N.; Chapman, Paul B.; Heller, Glenn; Yuan, Jianda; Young, James W.
2013-01-01
Purpose We compared the efficacy of human Langerhans cells (LCs) as tumor immunogens in vivo with monocyte-derived DCs (moDCs) and investigated how IL15 supports optimal DC-stimulated antitumor immunity. Experimental Design AJCC stage III/IV melanoma patients participated in this first clinical trial comparing melanoma peptide-pulsed LC with moDC vaccines (NCT00700167,www.ClinicalTrials.gov). Correlative studies evaluated mechanisms mediating IL15 support of DC-stimulated antitumor immunity. Results Both DC vaccines were safe and immunogenic for melanoma antigens. LC-based vaccines stimulated significantly greater tyrosinase-HLA-A*0201 tetramer reactivity than did moDC-based vaccines. The two DC subtypes were otherwise statistically comparable, in contrast to extensive prior data in vitro demonstrating LC superiority. LCs synthesize much more IL15 than moDCs and stimulate significantly more antigen-specific lymphocytes with a cytolytic IFN-gamma profile even without exogenous IL15. When supplemented by low dose IL15, instead of IL2, moDCs stimulate 5-6 logs more tumor antigen-specific effector memory T-cells (TEMRA) over 3-4 weeks in vitro. IL2 and IL15 can be synergistic in moDC stimulation of cytolytic T-cells. IL15 promotes T-cell expression of the antiapoptotic bcl-2 and inhibits candidate regulatory T-cell (Treg) expansion after DC stimulation, countering two effects of IL2 that do not foster tumor immunity. Conclusions MoDC-based vaccines will require exogenous IL15 to achieve clinical efficacy. Alternatively, LCs can couple the endogenous production of IL15 with potent T-cell stimulatory activity. Optimization of full length tumor antigen expression for processing into multiple immunogenic peptides for presentation by both class I and II MHC therefore merits emphasis to support more effective antitumor immunity stimulated by LCs. PMID:21355077
Su, Fei; Wang, Jiang; Niu, Shuangxia; Li, Huiyan; Deng, Bin; Liu, Chen; Wei, Xile
2018-02-01
The efficacy of deep brain stimulation (DBS) for Parkinson's disease (PD) depends in part on the post-operative programming of stimulation parameters. Closed-loop stimulation is one method to realize the frequent adjustment of stimulation parameters. This paper introduced the nonlinear predictive control method into the online adjustment of DBS amplitude and frequency. This approach was tested in a computational model of basal ganglia-thalamic network. The autoregressive Volterra model was used to identify the process model based on physiological data. Simulation results illustrated the efficiency of closed-loop stimulation methods (amplitude adjustment and frequency adjustment) in improving the relay reliability of thalamic neurons compared with the PD state. Besides, compared with the 130Hz constant DBS the closed-loop stimulation methods can significantly reduce the energy consumption. Through the analysis of inter-spike-intervals (ISIs) distribution of basal ganglia neurons, the evoked network activity by the closed-loop frequency adjustment stimulation was closer to the normal state. Copyright © 2017 Elsevier Ltd. All rights reserved.
Nanomaterial-Enabled Neural Stimulation
Wang, Yongchen; Guo, Liang
2016-01-01
Neural stimulation is a critical technique in treating neurological diseases and investigating brain functions. Traditional electrical stimulation uses electrodes to directly create intervening electric fields in the immediate vicinity of neural tissues. Second-generation stimulation techniques directly use light, magnetic fields or ultrasound in a non-contact manner. An emerging generation of non- or minimally invasive neural stimulation techniques is enabled by nanotechnology to achieve a high spatial resolution and cell-type specificity. In these techniques, a nanomaterial converts a remotely transmitted primary stimulus such as a light, magnetic or ultrasonic signal to a localized secondary stimulus such as an electric field or heat to stimulate neurons. The ease of surface modification and bio-conjugation of nanomaterials facilitates cell-type-specific targeting, designated placement and highly localized membrane activation. This review focuses on nanomaterial-enabled neural stimulation techniques primarily involving opto-electric, opto-thermal, magneto-electric, magneto-thermal and acousto-electric transduction mechanisms. Stimulation techniques based on other possible transduction schemes and general consideration for these emerging neurotechnologies are also discussed. PMID:27013938
Review of devices used in neuromuscular electrical stimulation for stroke rehabilitation.
Takeda, Kotaro; Tanino, Genichi; Miyasaka, Hiroyuki
2017-01-01
Neuromuscular electrical stimulation (NMES), specifically functional electrical stimulation (FES) that compensates for voluntary motion, and therapeutic electrical stimulation (TES) aimed at muscle strengthening and recovery from paralysis are widely used in stroke rehabilitation. The electrical stimulation of muscle contraction should be synchronized with intended motion to restore paralysis. Therefore, NMES devices, which monitor electromyogram (EMG) or electroencephalogram (EEG) changes with motor intention and use them as a trigger, have been developed. Devices that modify the current intensity of NMES, based on EMG or EEG, have also been proposed. Given the diversity in devices and stimulation methods of NMES, the aim of the current review was to introduce some commercial FES and TES devices and application methods, which depend on the condition of the patient with stroke, including the degree of paralysis.
Transcranial direct current stimulation enhances recovery of stereopsis in adults with amblyopia.
Spiegel, Daniel P; Li, Jinrong; Hess, Robert F; Byblow, Winston D; Deng, Daming; Yu, Minbin; Thompson, Benjamin
2013-10-01
Amblyopia is a neurodevelopmental disorder of vision caused by abnormal visual experience during early childhood that is often considered to be untreatable in adulthood. Recently, it has been shown that a novel dichoptic videogame-based treatment for amblyopia can improve visual function in adult patients, at least in part, by reducing inhibition of inputs from the amblyopic eye to the visual cortex. Non-invasive anodal transcranial direct current stimulation has been shown to reduce the activity of inhibitory cortical interneurons when applied to the primary motor or visual cortex. In this double-blind, sham-controlled cross-over study we tested the hypothesis that anodal transcranial direct current stimulation of the visual cortex would enhance the therapeutic effects of dichoptic videogame-based treatment. A homogeneous group of 16 young adults (mean age 22.1 ± 1.1 years) with amblyopia were studied to compare the effect of dichoptic treatment alone and dichoptic treatment combined with visual cortex direct current stimulation on measures of binocular (stereopsis) and monocular (visual acuity) visual function. The combined treatment led to greater improvements in stereoacuity than dichoptic treatment alone, indicating that direct current stimulation of the visual cortex boosts the efficacy of dichoptic videogame-based treatment. This intervention warrants further evaluation as a novel therapeutic approach for adults with amblyopia.
Aoyagi, Yoichiro; Tsubahara, Akio
2004-01-01
Upper extremity hemiplegia after stroke is common and disabling. Apart from conventional physical and occupational therapy, a number of additional approaches that use devices such as orthoses, prostheses, electrical stimulation, and robots have been introduced. The purpose of this review was to assess the clinical efficacy of such devices used for the affected upper extremities of acute, subacute, and chronic stroke patients. Assessments of their effectiveness and recommendations were based on the weight of published scientific evidence. The amount of evidence with respect to hand splints and shoulder slings is limited. Further study with a well-designed randomized controlled trial (RCT) is required to investigate accurately their short- and long-term efficacy. A number of studies suggested that the use of electrical stimulation for reducing shoulder subluxation or improving the function of wrist and finger extensors is effective during or shortly after the daily treatment period. The robotic approach to hemiplegic upper extremities appears to be a novel therapeutic strategy that may help improve hand and arm function. However, the longer term effectiveness after discontinuation as well as the motor recovery mechanism of electrical stimulation or robotic devices remains unclear. More research is needed to determine the evidence-based effectiveness of electrical stimulation or other devices for stroke survivors.
Ferrante, Simona; Pedrocchi, Alessandra; Iannò, Marco; De Momi, Elena; Ferrarin, Maurizio; Ferrigno, Giancarlo
2004-01-01
This study falls within the ambit of research on functional electrical stimulation for the design of rehabilitation training for spinal cord injured patients. In this context, a crucial issue is the control of the stimulation parameters in order to optimize the patterns of muscle activation and to increase the duration of the exercises. An adaptive control system (NEURADAPT) based on artificial neural networks (ANNs) was developed to control the knee joint in accordance with desired trajectories by stimulating quadriceps muscles. This strategy includes an inverse neural model of the stimulated limb in the feedforward line and a neural network trained on-line in the feedback loop. NEURADAPT was compared with a linear closed-loop proportional integrative derivative (PID) controller and with a model-based neural controller (NEUROPID). Experiments on two subjects (one healthy and one paraplegic) show the good performance of NEURADAPT, which is able to reduce the time lag introduced by the PID controller. In addition, control systems based on ANN techniques do not require complicated calibration procedures at the beginning of each experimental session. After the initial learning phase, the ANN, thanks to its generalization capacity, is able to cope with a certain range of variability of skeletal muscle properties.
NASA Technical Reports Server (NTRS)
Koehne, Jessica E.
2016-01-01
A sensor platform based on vertically aligned carbon nanofibers (CNFs) has been developed. Their inherent nanometer scale, high conductivity, wide potential window, good biocompatibility and well-defined surface chemistry make them ideal candidates as biosensor electrodes. Here, we report two studies using vertically aligned CNF nanoelectrodes for biomedical applications. CNF arrays are investigated as neural stimulation and neurotransmitter recording electrodes for application in deep brain stimulation (DBS). Polypyrrole coated CNF nanoelectrodes have shown great promise as stimulating electrodes due to their large surface area, low impedance, biocompatibility and capacity for highly localized stimulation. CNFs embedded in SiO2 have been used as sensing electrodes for neurotransmitter detection. Our approach combines a multiplexed CNF electrode chip, developed at NASA Ames Research Center, with the Wireless Instantaneous Neurotransmitter Concentration Sensor (WINCS) system, developed at the Mayo Clinic. Preliminary results indicate that the CNF nanoelectrode arrays are easily integrated with WINCS for neurotransmitter detection in a multiplexed array format. In the future, combining CNF based stimulating and recording electrodes with WINCS may lay the foundation for an implantable smart therapeutic system that utilizes neurochemical feedback control while likely resulting in increased DBS application in various neuropsychiatric disorders. In total, our goal is to take advantage of the nanostructure of CNF arrays for biosensing studies requiring ultrahigh sensitivity, high-degree of miniaturization, and selective biofunctionalization.
NASA Technical Reports Server (NTRS)
Koehne, Jessica E.
2016-01-01
A sensor platform based on vertically aligned carbon nanofibers (CNFs) has been developed. Their inherent nanometer scale, high conductivity, wide potential window, good biocompatibility and well-defined surface chemistry make them ideal candidates as biosensor electrodes. Here, we report two studies using vertically aligned CNF nanoelectrodes for biomedical applications. CNF arrays are investigated as neural stimulation and neurotransmitter recording electrodes for application in deep brain stimulation (DBS). Polypyrrole coated CNF nanoelectrodes have shown great promise as stimulating electrodes due to their large surface area, low impedance, biocompatibility and capacity for highly localized stimulation. CNFs embedded in SiO2 have been used as sensing electrodes for neurotransmitter detection. Our approach combines a multiplexed CNF electrode chip, developed at NASA Ames Research Center, with the Wireless Instantaneous Neurotransmitter Concentration Sensor (WINCS) system, developed at the Mayo Clinic. Preliminary results indicate that the CNF nanoelectrode arrays are easily integrated with WINCS for neurotransmitter detection in a multiplexed array format. In the future, combining CNF based stimulating and recording electrodes with WINCS may lay the foundation for an implantable "smart" therapeutic system that utilizes neurochemical feedback control while likely resulting in increased DBS application in various neuropsychiatric disorders. In total, our goal is to take advantage of the nanostructure of CNF arrays for biosensing studies requiring ultrahigh sensitivity, high-degree of miniaturization, and selective biofunctionalization.
Stimulating the Comfort of Textile Electrodes in Wearable Neuromuscular Electrical Stimulation.
Zhou, Hui; Lu, Yi; Chen, Wanzhen; Wu, Zhen; Zou, Haiqing; Krundel, Ludovic; Li, Guanglin
2015-07-16
Textile electrodes are becoming an attractive means in the facilitation of surface electrical stimulation. However, the stimulation comfort of textile electrodes and the mechanism behind stimulation discomfort is still unknown. In this study, a textile stimulation electrode was developed using conductive fabrics and then its impedance spectroscopy, stimulation thresholds, and stimulation comfort were quantitatively assessed and compared with those of a wet textile electrode and a hydrogel electrode on healthy subjects. The equivalent circuit models and the finite element models of different types of electrode were built based on the measured impedance data of the electrodes to reveal the possible mechanism of electrical stimulation pain. Our results showed that the wet textile electrode could achieve similar stimulation performance as the hydrogel electrode in motor threshold and stimulation comfort. However, the dry textile electrode was found to have very low pain threshold and induced obvious cutaneous painful sensations during stimulation, in comparison to the wet and hydrogel electrodes. Indeed, the finite element modeling results showed that the activation function along the z direction at the depth of dermis epidermis junction of the dry textile electrode was significantly larger than that of the wet and hydrogel electrodes, thus resulting in stronger activation of pain sensing fibers. Future work will be done to make textile electrodes have similar stimulation performance and comfort as hydrogel electrodes.
Stimulating the Comfort of Textile Electrodes in Wearable Neuromuscular Electrical Stimulation
Zhou, Hui; Lu, Yi; Chen, Wanzhen; Wu, Zhen; Zou, Haiqing; Krundel, Ludovic; Li, Guanglin
2015-01-01
Textile electrodes are becoming an attractive means in the facilitation of surface electrical stimulation. However, the stimulation comfort of textile electrodes and the mechanism behind stimulation discomfort is still unknown. In this study, a textile stimulation electrode was developed using conductive fabrics and then its impedance spectroscopy, stimulation thresholds, and stimulation comfort were quantitatively assessed and compared with those of a wet textile electrode and a hydrogel electrode on healthy subjects. The equivalent circuit models and the finite element models of different types of electrode were built based on the measured impedance data of the electrodes to reveal the possible mechanism of electrical stimulation pain. Our results showed that the wet textile electrode could achieve similar stimulation performance as the hydrogel electrode in motor threshold and stimulation comfort. However, the dry textile electrode was found to have very low pain threshold and induced obvious cutaneous painful sensations during stimulation, in comparison to the wet and hydrogel electrodes. Indeed, the finite element modeling results showed that the activation function along the z direction at the depth of dermis epidermis junction of the dry textile electrode was significantly larger than that of the wet and hydrogel electrodes, thus resulting in stronger activation of pain sensing fibers. Future work will be done to make textile electrodes have similar stimulation performance and comfort as hydrogel electrodes. PMID:26193273
Tait, Robert J; McKetin, Rebecca; Kay-Lambkin, Frances; Bennett, Kylie; Tam, Ada; Bennett, Anthony; Geddes, Jenny; Garrick, Adam; Christensen, Helen; Griffiths, Kathleen M
2012-06-25
The prevalence of amphetamine-type stimulant use is greater than that of opioids and cocaine combined. Currently, there are no approved pharmacotherapy treatments for amphetamine-type stimulant problems, but some face-to-face psychotherapies are of demonstrated effectiveness. However, most treatment services focus on alcohol or opioid disorders, have limited reach and may not appeal to users of amphetamine-type stimulants. Internet interventions have proven to be effective for some substance use problems but none has specifically targeted users of amphetamine-type stimulants. The study will use a randomized controlled trial design to evaluate the effect of an internet intervention for amphetamine-type stimulant problems compared with a waitlist control group. The primary outcome will be assessed as amphetamine-type stimulant use (baseline, 3 and 6 months). Other outcomes measures will include 'readiness to change', quality of life, psychological distress (K-10 score), days out of role, poly-drug use, help-seeking intention and help-seeking behavior. The intervention consists of three modules requiring an estimated total completion time of 90 minutes. The content of the modules was adapted from face-to-face clinical techniques based on cognitive behavior therapy and motivation enhancement. The target sample is 160 men and women aged 18 and over who have used amphetamine-type stimulants in the last 3 months. To our knowledge this will be the first randomized controlled trial of an internet intervention specifically developed for users of amphetamine-type stimulants. If successful, the intervention will offer greater reach than conventional therapies and may engage clients who do not generally seek treatment from existing service providers. Australian and New Zealand Clinical Trials Registry (http://www.anzctr.org.au/) ACTRN12611000947909.
2012-01-01
Background The prevalence of amphetamine-type stimulant use is greater than that of opioids and cocaine combined. Currently, there are no approved pharmacotherapy treatments for amphetamine-type stimulant problems, but some face-to-face psychotherapies are of demonstrated effectiveness. However, most treatment services focus on alcohol or opioid disorders, have limited reach and may not appeal to users of amphetamine-type stimulants. Internet interventions have proven to be effective for some substance use problems but none has specifically targeted users of amphetamine-type stimulants. Design/method The study will use a randomized controlled trial design to evaluate the effect of an internet intervention for amphetamine-type stimulant problems compared with a waitlist control group. The primary outcome will be assessed as amphetamine-type stimulant use (baseline, 3 and 6 months). Other outcomes measures will include ‘readiness to change’, quality of life, psychological distress (K-10 score), days out of role, poly-drug use, help-seeking intention and help-seeking behavior. The intervention consists of three modules requiring an estimated total completion time of 90 minutes. The content of the modules was adapted from face-to-face clinical techniques based on cognitive behavior therapy and motivation enhancement. The target sample is 160 men and women aged 18 and over who have used amphetamine-type stimulants in the last 3 months. Discussion To our knowledge this will be the first randomized controlled trial of an internet intervention specifically developed for users of amphetamine-type stimulants. If successful, the intervention will offer greater reach than conventional therapies and may engage clients who do not generally seek treatment from existing service providers. Trial registration Australian and New Zealand Clinical Trials Registry (www.anzctr.org.au/) ACTRN12611000947909 PMID:22731926
Environmental Stimulation Model
ERIC Educational Resources Information Center
Zentall, Sydney S.
1977-01-01
An approach to treatment of hyperactive children is suggested which is based on the assumption that the hyperactive child is actually understimulated and hyperactive behaviors function to increase the external stimulation to approach a more optimal level. (Author/GW)
Olmstead, Todd A; Sindelar, Jody L; Petry, Nancy M
2007-03-16
To evaluate the cost-effectiveness of a prize-based intervention as an addition to usual care for stimulant abusers. This cost-effectiveness analysis is based on a randomized clinical trial implemented within the National Drug Abuse Treatment Clinical Trials Network. The trial was conducted at eight community-based outpatient psychosocial drug abuse treatment clinics. Four hundred and fifteen stimulant abusers were assigned to usual care (N=206) or usual care plus abstinence-based incentives (N=209) for 12 weeks. Participants randomized to the incentive condition earned the chance to draw for prizes for submitting substance negative samples; the number of draws earned increased with continuous abstinence time. Incremental cost-effectiveness ratios were estimated to compare prize-based incentives relative to usual care. The primary patient outcome was longest duration of confirmed stimulant abstinence (LDA). Unit costs were obtained via surveys administered at the eight participating clinics. Resource utilizations and patient outcomes were obtained from the clinical trial. Acceptability curves are presented to illustrate the uncertainty due to the sample and to provide policy relevant information. The incremental cost to lengthen the LDA by 1 week was 258 US dollars (95% confidence interval, 191-401 US dollars). Sensitivity analyses on several key parameters show that this value ranges from 163 to 269 US dollars. Compared with the usual care group, the incentive group had significantly longer LDAs and significantly higher costs.
Differential spatial activity patterns of acupuncture by a machine learning based analysis
NASA Astrophysics Data System (ADS)
You, Youbo; Bai, Lijun; Xue, Ting; Zhong, Chongguang; Liu, Zhenyu; Tian, Jie
2011-03-01
Acupoint specificity, lying at the core of the Traditional Chinese Medicine, underlies the theoretical basis of acupuncture application. However, recent studies have reported that acupuncture stimulation at nonacupoint and acupoint can both evoke similar signal intensity decreases in multiple regions. And these regions were spatially overlapped. We used a machine learning based Support Vector Machine (SVM) approach to elucidate the specific neural response pattern induced by acupuncture stimulation. Group analysis demonstrated that stimulation at two different acupoints (belong to the same nerve segment but different meridians) could elicit distinct neural response patterns. Our findings may provide evidence for acupoint specificity.
Bhanpuri, Nasir H; Bertucco, Matteo; Young, Scott J; Lee, Annie A; Sanger, Terence D
2015-10-01
Abnormal motor cortex activity is common in dystonia. Cathodal transcranial direct current stimulation may alter cortical activity by decreasing excitability while anodal stimulation may increase motor learning. Previous results showed that a single session of cathodal transcranial direct current stimulation can improve symptoms in childhood dystonia. Here we performed a 5-day, sham-controlled, double-blind, crossover study, where we measured tracking and muscle overflow in a myocontrol-based task. We applied cathodal and anodal transcranial direct current stimulation (2 mA, 9 minutes per day). For cathodal transcranial direct current stimulation (7 participants), 3 subjects showed improvements whereas 2 showed worsening in overflow or tracking error. The effect size was small (about 1% of maximum voluntary contraction) and not clinically meaningful. For anodal transcranial direct current stimulation (6 participants), none showed improvement, whereas 5 showed worsening. Thus, multiday cathodal transcranial direct current stimulation reduced symptoms in some children but not to a clinically meaningful extent, whereas anodal transcranial direct current stimulation worsened symptoms. Our results do not support transcranial direct current stimulation as clinically viable for treating childhood dystonia. © The Author(s) 2015.
The physiology of boredom, depression and senile dementia.
Saunders, M N
1996-05-01
Mental stimulation ensures the flow of blood, oxygen and nutrients to the brain. The stimulation can be either generated internally from thought and rumination or externally from our environment via the senses. Without this stimulation, neuron shrinkage and atrophy eventually may lead to depression and senile dementia. This paper explains why mental stimulation may be prevented from realizing its beneficial effects of increasing the blood flow to the brain. The hypothesis is based on feedback biological mechanisms that prevent overload of the neural circuitry due to excessive mental stimulation. However, if overstimulation is maintained over a long period and, with it, the overload protection process, it may eventually lead to permanent depletion of neuron connections and also neural communications.
Does case-mix based reimbursement stimulate the development of process-oriented care delivery?
Vos, Leti; Dückers, Michel L A; Wagner, Cordula; van Merode, Godefridus G
2010-11-01
Reimbursement based on the total care of a patient during an acute episode of illness is believed to stimulate management and clinicians to reduce quality problems like waiting times and poor coordination of care delivery. Although many studies already show that this kind of case-mix based reimbursement leads to more efficiency, it remains unclear whether care coordination improved as well. This study aims to explore whether case-mix based reimbursement stimulates development of care coordination by the use of care programmes, and a process-oriented way of working. Data for this study were gathered during the winter of 2007/2008 in a survey involving all Dutch hospitals. Descriptive and structural equation modelling (SEM) analyses were conducted. SEM reveals that adoption of the case-mix reimbursement within hospitals' budgeting processes stimulates hospitals to establish care programmes by the use of process-oriented performance measures. However, the implementation of care programmes is not (yet) accompanied by a change in focus from function (the delivery of independent care activities) to process (the delivery of care activities as being connected to a chain of interdependent care activities). This study demonstrates that hospital management can stimulate the development of care programmes by the adoption of case-mix reimbursement within hospitals' budgeting processes. Future research is recommended to confirm this finding and to determine whether the establishment of care programmes will in time indeed lead to a more process-oriented view of professionals. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Yi, Weibo; Qiu, Shuang; Wang, Kun; Qi, Hongzhi; Zhao, Xin; He, Feng; Zhou, Peng; Yang, Jiajia; Ming, Dong
2017-04-01
Objective. We proposed a novel simultaneous hybrid brain-computer interface (BCI) by incorporating electrical stimulation into a motor imagery (MI) based BCI system. The goal of this study was to enhance the overall performance of an MI-based BCI. In addition, the brain oscillatory pattern in the hybrid task was also investigated. Approach. 64-channel electroencephalographic (EEG) data were recorded during MI, selective attention (SA) and hybrid tasks in fourteen healthy subjects. In the hybrid task, subjects performed MI with electrical stimulation which was applied to bilateral median nerve on wrists simultaneously. Main results. The hybrid task clearly presented additional steady-state somatosensory evoked potential (SSSEP) induced by electrical stimulation with MI-induced event-related desynchronization (ERD). By combining ERD and SSSEP features, the performance in the hybrid task was significantly better than in both MI and SA tasks, achieving a ~14% improvement in total relative to the MI task alone and reaching ~89% in mean classification accuracy. On the contrary, there was no significant enhancement obtained in performance while separate ERD feature was utilized in the hybrid task. In terms of the hybrid task, the performance using combined feature was significantly better than using separate ERD or SSSEP feature. Significance. The results in this work validate the feasibility of our proposed approach to form a novel MI-SSSEP hybrid BCI outperforming a conventional MI-based BCI through combing MI with electrical stimulation.
Datta, Abhishek; Dmochowski, Jacek P; Guleyupoglu, Berkan; Bikson, Marom; Fregni, Felipe
2013-01-15
The field of non-invasive brain stimulation has developed significantly over the last two decades. Though two techniques of noninvasive brain stimulation--transcranial direct current stimulation (tDCS) and transcranial magnetic stimulation (TMS)--are becoming established tools for research in neuroscience and for some clinical applications, related techniques that also show some promising clinical results have not been developed at the same pace. One of these related techniques is cranial electrotherapy stimulation (CES), a class of transcranial pulsed current stimulation (tPCS). In order to understand further the mechanisms of CES, we aimed to model CES using a magnetic resonance imaging (MRI)-derived finite element head model including cortical and also subcortical structures. Cortical electric field (current density) peak intensities and distributions were analyzed. We evaluated different electrode configurations of CES including in-ear and over-ear montages. Our results confirm that significant amounts of current pass the skull and reach cortical and subcortical structures. In addition, depending on the montage, induced currents at subcortical areas, such as midbrain, pons, thalamus and hypothalamus are of similar magnitude than that of cortical areas. Incremental variations of electrode position on the head surface also influence which cortical regions are modulated. The high-resolution modeling predictions suggest that details of electrode montage influence current flow through superficial and deep structures. Finally we present laptop based methods for tPCS dose design using dominant frequency and spherical models. These modeling predictions and tools are the first step to advance rational and optimized use of tPCS and CES. Copyright © 2012 Elsevier Inc. All rights reserved.
Electrical stimulus artifact cancellation and neural spike detection on large multi-electrode arrays
Grosberg, Lauren E.; Madugula, Sasidhar; Litke, Alan; Cunningham, John; Chichilnisky, E. J.; Paninski, Liam
2017-01-01
Simultaneous electrical stimulation and recording using multi-electrode arrays can provide a valuable technique for studying circuit connectivity and engineering neural interfaces. However, interpreting these measurements is challenging because the spike sorting process (identifying and segregating action potentials arising from different neurons) is greatly complicated by electrical stimulation artifacts across the array, which can exhibit complex and nonlinear waveforms, and overlap temporarily with evoked spikes. Here we develop a scalable algorithm based on a structured Gaussian Process model to estimate the artifact and identify evoked spikes. The effectiveness of our methods is demonstrated in both real and simulated 512-electrode recordings in the peripheral primate retina with single-electrode and several types of multi-electrode stimulation. We establish small error rates in the identification of evoked spikes, with a computational complexity that is compatible with real-time data analysis. This technology may be helpful in the design of future high-resolution sensory prostheses based on tailored stimulation (e.g., retinal prostheses), and for closed-loop neural stimulation at a much larger scale than currently possible. PMID:29131818
Montagna, Fabio; Buiatti, Marco; Benatti, Simone; Rossi, Davide; Farella, Elisabetta; Benini, Luca
2017-10-01
EEG is a standard non-invasive technique used in neural disease diagnostics and neurosciences. Frequency-tagging is an increasingly popular experimental paradigm that efficiently tests brain function by measuring EEG responses to periodic stimulation. Recently, frequency-tagging paradigms have proven successful with low stimulation frequencies (0.5-6Hz), but the EEG signal is intrinsically noisy in this frequency range, requiring heavy signal processing and significant human intervention for response estimation. This limits the possibility to process the EEG on resource-constrained systems and to design smart EEG based devices for automated diagnostic. We propose an algorithm for artifact removal and automated detection of frequency tagging responses in a wide range of stimulation frequencies, which we test on a visual stimulation protocol. The algorithm is rooted on machine learning based pattern recognition techniques and it is tailored for a new generation parallel ultra low power processing platform (PULP), reaching performance of more that 90% accuracy in the frequency detection even for very low stimulation frequencies (<1Hz) with a power budget of 56mW. Copyright © 2017 Elsevier Inc. All rights reserved.
Zhu, Yunqi; Xu, Kedi; Xu, Caiyun; Zhang, Jiacheng; Ji, Jianfeng; Zheng, Xiaoxiang; Zhang, Hong; Tian, Mei
2016-07-01
Brain-computer interface (BCI) technology has great potential for improving the quality of life for neurologic patients. This study aimed to use PET mapping for BCI-based stimulation in a rat model with electrodes implanted in the ventroposterior medial (VPM) nucleus of the thalamus. PET imaging studies were conducted before and after stimulation of the right VPM. Stimulation induced significant orienting performance. (18)F-FDG uptake increased significantly in the paraventricular thalamic nucleus, septohippocampal nucleus, olfactory bulb, left crus II of the ansiform lobule of the cerebellum, and bilaterally in the lateral septum, amygdala, piriform cortex, endopiriform nucleus, and insular cortex, but it decreased in the right secondary visual cortex, right simple lobule of the cerebellum, and bilaterally in the somatosensory cortex. This study demonstrated that PET mapping after VPM stimulation can identify specific brain regions associated with orienting performance. PET molecular imaging may be an important approach for BCI-based research and its clinical applications. © 2016 by the Society of Nuclear Medicine and Molecular Imaging, Inc.
Mena, Gonzalo E; Grosberg, Lauren E; Madugula, Sasidhar; Hottowy, Paweł; Litke, Alan; Cunningham, John; Chichilnisky, E J; Paninski, Liam
2017-11-01
Simultaneous electrical stimulation and recording using multi-electrode arrays can provide a valuable technique for studying circuit connectivity and engineering neural interfaces. However, interpreting these measurements is challenging because the spike sorting process (identifying and segregating action potentials arising from different neurons) is greatly complicated by electrical stimulation artifacts across the array, which can exhibit complex and nonlinear waveforms, and overlap temporarily with evoked spikes. Here we develop a scalable algorithm based on a structured Gaussian Process model to estimate the artifact and identify evoked spikes. The effectiveness of our methods is demonstrated in both real and simulated 512-electrode recordings in the peripheral primate retina with single-electrode and several types of multi-electrode stimulation. We establish small error rates in the identification of evoked spikes, with a computational complexity that is compatible with real-time data analysis. This technology may be helpful in the design of future high-resolution sensory prostheses based on tailored stimulation (e.g., retinal prostheses), and for closed-loop neural stimulation at a much larger scale than currently possible.
Two-Photon Excitation STED Microscopy with Time-Gated Detection
Coto Hernández, Iván; Castello, Marco; Lanzanò, Luca; d’Amora, Marta; Bianchini, Paolo; Diaspro, Alberto; Vicidomini, Giuseppe
2016-01-01
We report on a novel two-photon excitation stimulated emission depletion (2PE-STED) microscope based on time-gated detection. The time-gated detection allows for the effective silencing of the fluorophores using moderate stimulated emission beam intensity. This opens the possibility of implementing an efficient 2PE-STED microscope with a stimulated emission beam running in a continuous-wave. The continuous-wave stimulated emission beam tempers the laser architecture’s complexity and cost, but the time-gated detection degrades the signal-to-noise ratio (SNR) and signal-to-background ratio (SBR) of the image. We recover the SNR and the SBR through a multi-image deconvolution algorithm. Indeed, the algorithm simultaneously reassigns early-photons (normally discarded by the time-gated detection) to their original positions and removes the background induced by the stimulated emission beam. We exemplify the benefits of this implementation by imaging sub-cellular structures. Finally, we discuss of the extension of this algorithm to future all-pulsed 2PE-STED implementationd based on time-gated detection and a nanosecond laser source. PMID:26757892
Design and Evaluation of a Personal Digital Assistant-based Research Platform for Cochlear Implants
Ali, Hussnain; Lobo, Arthur P.; Loizou, Philipos C.
2014-01-01
This paper discusses the design, development, features, and clinical evaluation of a personal digital assistant (PDA)-based platform for cochlear implant research. This highly versatile and portable research platform allows researchers to design and perform complex experiments with cochlear implants manufactured by Cochlear Corporation with great ease and flexibility. The research platform includes a portable processor for implementing and evaluating novel speech processing algorithms, a stimulator unit which can be used for electrical stimulation and neurophysio-logic studies with animals, and a recording unit for collecting electroencephalogram/evoked potentials from human subjects. The design of the platform for real time and offline stimulation modes is discussed for electric-only and electric plus acoustic stimulation followed by results from an acute study with implant users for speech intelligibility in quiet and noisy conditions. The results are comparable with users’ clinical processor and very promising for undertaking chronic studies. PMID:23674422
Aphasia: Current Concepts in Theory and Practice
Tippett, Donna C.; Niparko, John K.; Hillis, Argye E.
2014-01-01
Recent advances in neuroimaging contribute to a new insights regarding brain-behavior relationships and expand understanding of the functional neuroanatomy of language. Modern concepts of the functional neuroanatomy of language invoke rich and complex models of language comprehension and expression, such as dual stream networks. Increasingly, aphasia is seen as a disruption of cognitive processes underlying language. Rehabilitation of aphasia incorporates evidence based and person-centered approaches. Novel techniques, such as methods of delivering cortical brain stimulation to modulate cortical excitability, such as repetitive transcranial magnetic stimulation and transcranial direct current stimulation, are just beginning to be explored. In this review, we discuss the historical context of the foundations of neuroscientific approaches to language. We sample the emergent theoretical models of the neural substrates of language and cognitive processes underlying aphasia that contribute to more refined and nuanced concepts of language. Current concepts of aphasia rehabilitation are reviewed, including the promising role of cortical stimulation as an adjunct to behavioral therapy and changes in therapeutic approaches based on principles of neuroplasticity and evidence-based/person-centered practice to optimize functional outcomes. PMID:24904925
Chung, EunJung; Kim, Jung-Hee; Park, Dae-Sung; Lee, Byoung-Hee
2015-03-01
[Purpose] This study sought to determine the effects of brain-computer interface-based functional electrical stimulation (BCI-FES) on brain activation in patients with stroke. [Subjects] The subjects were randomized to in a BCI-FES group (n=5) and a functional electrical stimulation (FES) group (n=5). [Methods] Patients in the BCI-FES group received ankle dorsiflexion training with FES for 30 minutes per day, 5 times under the brain-computer interface-based program. The FES group received ankle dorsiflexion training with FES for the same amount of time. [Results] The BCI-FES group demonstrated significant differences in the frontopolar regions 1 and 2 attention indexes, and frontopolar 1 activation index. The FES group demonstrated no significant differences. There were significant differences in the frontopolar 1 region activation index between the two groups after the interventions. [Conclusion] The results of this study suggest that BCI-FES training may be more effective in stimulating brain activation than only FES training in patients recovering from stroke.
Nihonsugi, Tsuyoshi; Ihara, Aya; Haruno, Masahiko
2015-02-25
The intention behind another's action and the impact of the outcome are major determinants of human economic behavior. It is poorly understood, however, whether the two systems share a core neural computation. Here, we investigated whether the two systems are causally dissociable in the brain by integrating computational modeling, functional magnetic resonance imaging, and transcranial direct current stimulation experiments in a newly developed trust game task. We show not only that right dorsolateral prefrontal cortex (DLPFC) activity is correlated with intention-based economic decisions and that ventral striatum and amygdala activity are correlated with outcome-based decisions, but also that stimulation to the DLPFC selectively enhances intention-based decisions. These findings suggest that the right DLPFC is involved in the implementation of intention-based decisions in the processing of cooperative decisions. This causal dissociation of cortical and subcortical backgrounds may indicate evolutionary and developmental differences in the two decision systems. Copyright © 2015 the authors 0270-6474/15/53412-08$15.00/0.
[Which colours can we hear?: light stimulation of the hearing system].
Wenzel, G I; Lenarz, T; Schick, B
2014-02-01
The success of conventional hearing aids and electrical auditory prostheses for hearing impaired patients is still limited in noisy environments and for sounds more complex than speech (e. g. music). This is partially due to the difficulty of frequency-specific activation of the auditory system using these devices. Stimulation of the auditory system using light pulses represents an alternative to mechanical and electrical stimulation. Light is a source of energy that can be very exactly focused and applied with little scattering, thus offering perspectives for optimal activation of the auditory system. Studies investigating light stimulation of sectors along the auditory pathway have shown stimulation of the auditory system is possible using light pulses. However, further studies and developments are needed before a new generation of light stimulation-based auditory prostheses can be made available for clinical application.
Review of devices used in neuromuscular electrical stimulation for stroke rehabilitation
Takeda, Kotaro; Tanino, Genichi; Miyasaka, Hiroyuki
2017-01-01
Neuromuscular electrical stimulation (NMES), specifically functional electrical stimulation (FES) that compensates for voluntary motion, and therapeutic electrical stimulation (TES) aimed at muscle strengthening and recovery from paralysis are widely used in stroke rehabilitation. The electrical stimulation of muscle contraction should be synchronized with intended motion to restore paralysis. Therefore, NMES devices, which monitor electromyogram (EMG) or electroencephalogram (EEG) changes with motor intention and use them as a trigger, have been developed. Devices that modify the current intensity of NMES, based on EMG or EEG, have also been proposed. Given the diversity in devices and stimulation methods of NMES, the aim of the current review was to introduce some commercial FES and TES devices and application methods, which depend on the condition of the patient with stroke, including the degree of paralysis. PMID:28883745
Shon, Ahnsei; Chu, Jun-Uk; Jung, Jiuk; Kim, Hyungmin; Youn, Inchan
2017-12-21
Recently, implantable devices have become widely used in neural prostheses because they eliminate endemic drawbacks of conventional percutaneous neural interface systems. However, there are still several issues to be considered: low-efficiency wireless power transmission; wireless data communication over restricted operating distance with high power consumption; and limited functionality, working either as a neural signal recorder or as a stimulator. To overcome these issues, we suggest a novel implantable wireless neural interface system for simultaneous neural signal recording and stimulation using a single cuff electrode. By using widely available commercial off-the-shelf (COTS) components, an easily reconfigurable implantable wireless neural interface system was implemented into one compact module. The implantable device includes a wireless power consortium (WPC)-compliant power transmission circuit, a medical implant communication service (MICS)-band-based radio link and a cuff-electrode path controller for simultaneous neural signal recording and stimulation. During in vivo experiments with rabbit models, the implantable device successfully recorded and stimulated the tibial and peroneal nerves while communicating with the external device. The proposed system can be modified for various implantable medical devices, especially such as closed-loop control based implantable neural prostheses requiring neural signal recording and stimulation at the same time.
Shon, Ahnsei; Chu, Jun-Uk; Jung, Jiuk; Youn, Inchan
2017-01-01
Recently, implantable devices have become widely used in neural prostheses because they eliminate endemic drawbacks of conventional percutaneous neural interface systems. However, there are still several issues to be considered: low-efficiency wireless power transmission; wireless data communication over restricted operating distance with high power consumption; and limited functionality, working either as a neural signal recorder or as a stimulator. To overcome these issues, we suggest a novel implantable wireless neural interface system for simultaneous neural signal recording and stimulation using a single cuff electrode. By using widely available commercial off-the-shelf (COTS) components, an easily reconfigurable implantable wireless neural interface system was implemented into one compact module. The implantable device includes a wireless power consortium (WPC)-compliant power transmission circuit, a medical implant communication service (MICS)-band-based radio link and a cuff-electrode path controller for simultaneous neural signal recording and stimulation. During in vivo experiments with rabbit models, the implantable device successfully recorded and stimulated the tibial and peroneal nerves while communicating with the external device. The proposed system can be modified for various implantable medical devices, especially such as closed-loop control based implantable neural prostheses requiring neural signal recording and stimulation at the same time. PMID:29267230
Predicting students' intention to use stimulants for academic performance enhancement.
Ponnet, Koen; Wouters, Edwin; Walrave, Michel; Heirman, Wannes; Van Hal, Guido
2015-02-01
The non-medical use of stimulants for academic performance enhancement is becoming a more common practice among college and university students. The objective of this study is to gain a better understanding of students' intention to use stimulant medication for the purpose of enhancing their academic performance. Based on an extended model of Ajzen's theory of planned behavior, we examined the predictive value of attitude, subjective norm, perceived behavioral control, psychological distress, procrastination, substance use, and alcohol use on students' intention to use stimulants to improve their academic performance. The sample consisted of 3,589 Flemish university and college students (mean age: 21.59, SD: 4.09), who participated anonymously in an online survey conducted in March and April 2013. Structural equation modeling was used to investigate the relationships among the study variables. Our results indicate that subjective norm is the strongest predictor of students' intention to use stimulant medication, followed by attitude and perceived behavioral control. To a lesser extent, procrastinating tendencies, psychological distress, and substance abuse contribute to students' intention. Conclusions/ Importance: Based on these findings, we provide several recommendations on how to curtail students' intention to use stimulant medication for the purpose of improving their academic performance. In addition, we urge researchers to identify other psychological variables that might be related to students' intention.
Lyons, R; Jones, S; Kemp, A; Sibert, J; Shepherd, J; Richmond, P; Bartlett, C; Palmer, S
2002-01-01
This report details the development and use of a population based emergency room surveillance system in the UK. Despite some difficulties in accessing high quality data the system has stimulated a considerable number of research and intervention projects. While surveillance systems with high quality data collection and coding parameters remain the gold standard, imperfect systems, particularly if population based, can play a substantial part in stimulating injury prevention initiatives. PMID:11928983
Tsujii, Takeo; Sakatani, Kaoru; Masuda, Sayako; Akiyama, Takekazu; Watanabe, Shigeru
2011-09-15
This study used off-line repetitive transcranial magnetic stimulation (rTMS) to examine the roles of the superior parietal lobule (SPL) and inferior frontal gyrus (IFG) in a deductive reasoning task. Subjects performed a categorical syllogistic reasoning task involving congruent, incongruent, and abstract trials. Twenty four subjects received magnetic stimulation to the SPL region prior to the task. In the other 24 subjects, TMS was administered to the IFG region before the task. Stimulation lasted for 10min, with an inter-pulse frequency of 1Hz. We found that bilateral SPL (Brodmann area (BA) 7) stimulation disrupted performance on abstract and incongruent reasoning. Left IFG (BA 45) stimulation impaired congruent reasoning performance while paradoxically facilitating incongruent reasoning performance. This resulted in the elimination of the belief-bias. In contrast, right IFG stimulation only impaired incongruent reasoning performance, thus enhancing the belief-bias effect. These findings are largely consistent with the dual-process theory of reasoning, which proposes the existence of two different human reasoning systems: a belief-based heuristic system; and a logic-based analytic system. The present findings suggest that the left language-related IFG (BA 45) may correspond to the heuristic system, while bilateral SPL may underlie the analytic system. The right IFG may play a role in blocking the belief-based heuristic system for solving incongruent reasoning trials. This study could offer an insight about functional roles of distributed brain systems in human deductive reasoning by utilizing the rTMS approach. Copyright © 2011 Elsevier Inc. All rights reserved.
A novel stimulation method for multi-class SSVEP-BCI using intermodulation frequencies
NASA Astrophysics Data System (ADS)
Chen, Xiaogang; Wang, Yijun; Zhang, Shangen; Gao, Shangkai; Hu, Yong; Gao, Xiaorong
2017-04-01
Objective. Steady-state visual evoked potential (SSVEP)-based brain-computer interface (BCI) has been widely investigated because of its easy system configuration, high information transfer rate (ITR) and little user training. However, due to the limitations of brain responses and the refresh rate of a monitor, the available stimulation frequencies for practical BCI application are generally restricted. Approach. This study introduced a novel stimulation method using intermodulation frequencies for SSVEP-BCIs that had targets flickering at the same frequency but with different additional modulation frequencies. The additional modulation frequencies were generated on the basis of choosing desired flickering frequencies. The conventional frame-based ‘on/off’ stimulation method was used to realize the desired flickering frequencies. All visual stimulation was present on a conventional LCD screen. A 9-target SSVEP-BCI based on intermodulation frequencies was implemented for performance evaluation. To optimize the stimulation design, three approaches (C: chromatic; L: luminance; CL: chromatic and luminance) were evaluated by online testing and offline analysis. Main results. SSVEP-BCIs with different paradigms (C, L, and CL) enabled us not only to encode more targets, but also to reliably evoke intermodulation frequencies. The online accuracies for the three paradigms were 91.67% (C), 93.98% (L), and 96.41% (CL). The CL condition achieved the highest classification performance. Significance. These results demonstrated the efficacy of three approaches (C, L, and CL) for eliciting intermodulation frequencies for multi-class SSVEP-BCIs. The combination of chromatic and luminance characteristics of the visual stimuli is the most efficient way for the intermodulation frequency coding method.
Prenton, Sarah; Kenney, Laurence P; Stapleton, Claire; Cooper, Glen; Reeves, Mark L; Heller, Ben W; Sobuh, Mohammad; Barker, Anthony T; Healey, Jamie; Good, Timothy R; Thies, Sibylle B; Howard, David; Williamson, Tracey
2014-10-01
To investigate the feasibility of unsupervised community use of an array-based automated setup functional electrical stimulator for current foot-drop functional electrical stimulation (FES) users. Feasibility study. Gait laboratory and community use. Participants (N=7) with diagnosis of unilateral foot-drop of central neurologic origin (>6mo) who were regular users of a foot-drop FES system (>3mo). Array-based automated setup FES system for foot-drop (ShefStim). Logged usage, logged automated setup times for the array-based automated setup FES system and diary recording of problems experienced, all collected in the community environment. Walking speed, ankle angles at initial contact, foot clearance during swing, and the Quebec User Evaluation of Satisfaction with Assistive Technology version 2.0 (QUEST version 2.0) questionnaire, all collected in the gait laboratory. All participants were able to use the array-based automated setup FES system. Total setup time took longer than participants' own FES systems, and automated setup time was longer than in a previous study of a similar system. Some problems were experienced, but overall, participants were as satisfied with this system as their own FES system. The increase in walking speed (N=7) relative to no stimulation was comparable between both systems, and appropriate ankle angles at initial contact (N=7) and foot clearance during swing (n=5) were greater with the array-based automated setup FES system. This study demonstrates that an array-based automated setup FES system for foot-drop can be successfully used unsupervised. Despite setup's taking longer and some problems, users are satisfied with the system and it would appear as effective, if not better, at addressing the foot-drop impairment. Further product development of this unique system, followed by a larger-scale and longer-term study, is required before firm conclusions about its efficacy can be reached. Copyright © 2014 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
Altered spinal cord activity during sexual stimulation in women with SCI: a pilot fMRI study.
Alexander, Marcalee; Kozyrev, Natalie; Figley, Chase R; Richards, J Scott
2017-01-01
The objective of this study was to assess the feasibility of the use of functional magnetic resonance imaging (fMRI) to evaluate the spinal activation during sexual response of the thoracic, lumbar and sacral spinal cord. This is a laboratory-based pilot study in human females at a University-based medical center in the United States. In three healthy spinal cord injury (SCI) females, spinal cord activations during sexual audiovisual stimulation (alone), genital self-stimulation (alone) and simultaneous audiovisual and genital self-stimulation (combined) were assessed and then compared with each subjects' remaining sensory and motor function. Spinal fMRI responses of the intermediolateral columns were found during audiovisual stimulation in both subjects with incomplete injuries, but they were not observed in the subject with a complete injury. Moreover, sacral responses to combined stimulation differed greatly between the subjects with complete and incomplete injuries. These results not only provide the first in vivo documentation of spinal fMRI responses associated with sexual arousal in women with SCIs, but also suggest that spinal cord fMRI is capable of distinguishing between injury subtypes. Therefore, although there are certain limitations associated with fMRI during sexual stimulation (for example, movement artifacts, an artificially controlled environment and so), these findings demonstrate the potential utility of incorporating spinal cord fMRI in future research to evaluate the impact of specific patterns of SCI on sexual responses and/or the effects of treatment.
2016-01-01
Abstract When the brain is stimulated, for example, by sensory inputs or goal-oriented tasks, the brain initially responds with activities in specific areas. The subsequent pattern formation of functional networks is constrained by the structural connectivity (SC) of the brain. The extent to which information is processed over short- or long-range SC is unclear. Whole-brain models based on long-range axonal connections, for example, can partly describe measured functional connectivity dynamics at rest. Here, we study the effect of SC on the network response to stimulation. We use a human whole-brain network model comprising long- and short-range connections. We systematically activate each cortical or thalamic area, and investigate the network response as a function of its short- and long-range SC. We show that when the brain is operating at the edge of criticality, stimulation causes a cascade of network recruitments, collapsing onto a smaller space that is partly constrained by SC. We found both short- and long-range SC essential to reproduce experimental results. In particular, the stimulation of specific areas results in the activation of one or more resting-state networks. We suggest that the stimulus-induced brain activity, which may indicate information and cognitive processing, follows specific routes imposed by structural networks explaining the emergence of functional networks. We provide a lookup table linking stimulation targets and functional network activations, which potentially can be useful in diagnostics and treatments with brain stimulation. PMID:27752540
Optical stimulation of the hearing and deaf cochlea under thermal and stress confinement condition
NASA Astrophysics Data System (ADS)
Schultz, M.; Baumhoff, P.; Kallweit, N.; Sato, M.; Krüger, A.; Ripken, T.; Lenarz, T.; Kral, A.
2014-03-01
There is a controversy, to which extend cochlear stimulation with near infrared laser pulses at a wavelength of 1860 nm is based on optoacoustic stimulation of intact hair cells or -in contrast- is based on direct stimulation of the nerve cells in absence of functional hair cells. Thermal and stress confinement conditions apply, because of the pulse duration range (5 ns, 10 μs-20 ms) of the two lasers used. The dependency of the signal characteristics on pulse peak power and pulse duration was investigated in this study. The compound action potential (CAP) was measured during stimulation of the cochlea of four anaesthetized guinea pigs, which were hearing at first and afterwards acutely deafened using intracochlear neomycin-rinsing. For comparison hydrophone measurements in a water tank were performed to investigate the optoacoustic signals at different laser interaction regimes. With rising pulse peak power CAPs of the hearing animals showed first a threshold, then a positively correlated and finally a saturating dependency. CAPs also showed distinct responses at laser onset and offset separated with the pulse duration. At pulse durations shorter than physiological response times the signals merged. Basically the same signal characteristics were observed in the optoacoustic hydrophone measurements, scaled with the sensitivity and response time of the hydrophone. Taking together the qualitative correspondence in the signal response and the absence of any CAPs in deafened animals our results speak in favor of an optoacoustic stimulation of intact hair cells rather than a direct stimulation of nerve cells.
Grossöhmichen, Martin; Salcher, Rolf; Kreipe, Hans-Heinrich; Lenarz, Thomas; Maier, Hannes
2015-01-01
This work assesses the efficiency of the Codacs system actuator (Cochlear Ltd., Sydney Australia) in different inner ear stimulation modalities. Originally the actuator was intended for direct perilymph stimulation after stapedotomy using a piston prosthesis. A possible alternative application is the stimulation of middle ear structures or the round window (RW). Here the perilymph stimulation with a K-piston through a stapes footplate (SFP) fenestration (N = 10) as well as stimulation of the stapes head (SH) with a Bell prosthesis (N = 9), SFP stimulation with an Omega/Aerial prosthesis (N = 8) and reverse RW stimulation (N = 10) were performed in cadaveric human temporal bones (TBs). Codacs actuator output is expressed as equivalent sound pressure level (eq. SPL) using RW and SFP displacement responses, measured by Laser Doppler velocimetry as reference. The axial actuator coupling force in stimulation of stapes and RW was adjusted to ~5 mN. The Bell prosthesis and Omega/Aerial prosthesis stimulation generated similar mean eq. SPLs (Bell: 127.5-141.8 eq. dB SPL; Omega/Aerial: 123.6-143.9 eq. dB SPL), being significantly more efficient than K-piston perilymph stimulation (108.6-131.6 eq. dB SPL) and RW stimulation (108.3-128.2 eq. dB SPL). Our results demonstrate that SH, SFP and RW are adequate alternative stimulation sites for the Codacs actuator using coupling prostheses and an axial coupling force of ~5 mN. Based on the eq. SPLs, all investigated methods were adequate for in vivo hearing aid applications, provided that experimental conditions including constant coupling force will be implemented.
Neurostimulation for Drug-Resistant Epilepsy
DeGiorgio, Christopher M.; Krahl, Scott E.
2013-01-01
Purpose of Review: The purpose of this review is to provide an evidence-based update on the neurostimulation options available for patients with drug-resistant epilepsy in the United States and in European countries. Recent Findings: The field of neurostimulation for epilepsy has grown dramatically since 1997, when vagus nerve stimulation became the first device to be approved for epilepsy by the US Food and Drug Administration (FDA). New data from recently completed randomized controlled trials are available for deep brain stimulation of the anterior thalamus, responsive neurostimulation, and trigeminal nerve stimulation. Although vagus nerve stimulation is the only device currently approved in the United States, deep brain stimulation and responsive neurostimulation devices are awaiting FDA approval. Deep brain stimulation, trigeminal nerve stimulation, and transcutaneous vagus nerve stimulation are now approved for epilepsy in the European Union. In this article, the mechanisms of action, safety, and efficacy of new neurostimulation devices are reviewed, and the key advantages and disadvantages of each are discussed. Summary: The exponential growth of the field of neuromodulation for epilepsy is an exciting development; these new devices provide physicians with new options for patients with drug-resistant epilepsy. PMID:23739108
Olière, Stéphanie; Jolette-Riopel, Antoine; Potvin, Stéphane; Jutras-Aswad, Didier
2013-01-01
Cannabis is one of the most widely used illicit substance among users of stimulants such as cocaine and amphetamines. Interestingly, increasing recent evidence points toward the involvement of the endocannabinoid system (ECBS) in the neurobiological processes related to stimulant addiction. This article presents an up-to-date review with deep insights into the pivotal role of the ECBS in the neurobiology of stimulant addiction and the effects of its modulation on addictive behaviors. This article aims to: (1) review the role of cannabis use and ECBS modulation in the neurobiological substrates of psychostimulant addiction and (2) evaluate the potential of cannabinoid-based pharmacological strategies to treat stimulant addiction. A growing number of studies support a critical role of the ECBS and its modulation by synthetic or natural cannabinoids in various neurobiological and behavioral aspects of stimulants addiction. Thus, cannabinoids modulate brain reward systems closely involved in stimulants addiction, and provide further evidence that the cannabinoid system could be explored as a potential drug discovery target for treating addiction across different classes of stimulants. PMID:24069004
Rhythmic Haptic Stimuli Improve Short-Term Attention.
Zhang, Shusheng; Wang, Dangxiao; Afzal, Naqash; Zhang, Yuru; Wu, Ruilin
2016-01-01
Brainwave entrainment using rhythmic visual and/or auditory stimulation has shown its efficacy in modulating neural activities and cognitive ability. In the presented study, we aim to investigate whether rhythmic haptic stimulation could enhance short-term attention. An experiment with sensorimotor rhythm (SMR) increasing protocol was performed in which participants were presented sinusoidal vibrotactile stimulus of 15 Hz on their palm. Test of Variables of Attention (T.O.V.A.) was performed before and after the stimulating session. Electroencephalograph (EEG) was recorded across the stimulating session and the two attention test sessions. SMR band power manifested a significant increase after stimulation. Results of T.O.V.A. tests indicated an improvement in the attention of participants who had received the stimulation compared to the control group who had not received the stimulation. The D prime score of T.O.V.A. reveals that participants performed better in perceptual sensitivity and sustaining attention level compared to their baseline performance before the stimulating session. These findings highlight the potential value of using haptics-based brainwave entrainment for cognitive training.
Jingyi, Zhu
2015-01-01
The detecting mechanism of carbon nanotubes gas sensor based on multi-stable stochastic resonance (MSR) model was studied in this paper. A numerically stimulating model based on MSR was established. And gas-ionizing experiment by adding electronic white noise to induce 1.65 MHz periodic component in the carbon nanotubes gas sensor was performed. It was found that the signal-to-noise ratio (SNR) spectrum displayed 2 maximal values, which accorded to the change of the broken-line potential function. The experimental results of gas-ionizing experiment demonstrated that periodic component of 1.65 MHz had multiple MSR phenomena, which was in accordance with the numerical stimulation results. In this way, the numerical stimulation method provides an innovative method for the detecting mechanism research of carbon nanotubes gas sensor.
da Mata, A D S P; da Silva Marques, D N; Silveira, J M L; Marques, J R O F; de Melo Campos Felino, E T; Guilherme, N F R P M
2009-04-01
To compare salivary pH changes and stimulation efficacy of two different gustatory stimulants of salivary secretion (GSSS). Portuguese Dental Faculty Clinic. Double blind randomized controlled trial. One hundred and twenty volunteers were randomized to two intervention groups. Sample sized was calculated using an alpha error of 0.05 and a beta of 0.20. Participants were randomly assigned to receive a new gustatory stimulant of secretory secretion containing a weaker malic acid, fluoride and xylitol or a traditionally citric acid-based one. Saliva collection was obtained by established methods at different times. The salivary pH of the samples was determined with a pH meter and a microelectrode. Salivary pH variations and counts of subjects with pH below 5.5 for over 1 min and stimulated salivary flow were the main outcome measures. Both GSSS significantly stimulated salivary output without significant differences between the two groups. The new gustatory stimulant of salivary secretion presented a risk reduction of 80 +/- 10.6% (95% CI) when compared with the traditional one. Gustatory stimulants of salivary secretion with fluoride, xylitol and lower acid content maintain similar salivary stimulation capacity while reducing significantly the dental erosion predictive potential.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rumyantsev, V. V., E-mail: rumyantsev@ipm.sci-nnov.ru; Fadeev, M. A.; Morozov, S. V.
2016-12-15
The interband photoconductivity and photoluminescence in narrow-gap HgCdTe-based waveguide structures with quantum wells (QWs) (designed for long-wavelength stimulated emission under optical pumping) are investigated. The photoconductivity relaxation times in n-type structures reach several microseconds, due to which stimulated emission at a wavelength of 10.2 μm occurs at a low threshold pump intensity (~100 W/cm{sup 2}) at 20 K. In the p-type structures obtained by annealing (to increase the mercury vacancy concentration), even spontaneous emission from the QWs is not detected because of a dramatic decrease in the carrier lifetime with respect to Shockley–Read–Hall nonradiative recombination.
[Methods of brain stimulation based on weak electric current--future tool for the clinician?].
Kotilainen, Tuukka; Lehto, Soili M
2016-01-01
Methods of brain stimulation based on a weak electric current are non-invasive neuromodulation techniques. They include transcranial direct current, alternating current and random noise stimulation. These methods modify the membrane potential of neurons without triggering the action potential, and have been successfully utilized to influence cognition and regulation of emotions in healthy experimental subjects. In clinical studies, indications of the efficacy of these techniques have been obtained in the treatment of depression, schizophrenia, memory disorders and pain as well as in stroke rehabilitation. It is hoped that these techniques will become established as part of the care and rehabilitation of psychiatric and neurologic patients in the future.
Is there an ideal stimulation regimen for IVF for poor responders and does it change with age?
Osianlis, Tiki; Catt, James
2008-01-01
Purpose To determine whether there is a superior treatment modality for ‘poor’ responders. Method Retrospective analysis of three stimulation regimens, with patients stratified based on age, stimulation regime and response in previous cycles (“poor’ responder or “non poor” responder). Fertilisation, embryo utilisation and clinical pregnancy rates were assessed. There were a total of 1,608 cycles in the ‘poor’ responder and 8,489 cycles in the ‘non poor’ responder groups. Results In ‘poor’ responders there was no significant difference in fertilisation rate, nor utilisation rate between the three stimulation regimes and no differences in the pregnancy rate/initiated cycle irrespective of age and stimulation regimen in any of the groups. ‘Non poor’ responders had a significantly greater pregnancy rate/initiated cycle for all stimulation regimens in both age groups compared with ‘poor’ responders. Conclusion This large retrospective study of ‘poor’ responders has not shown a difference in pregnancy rates/initiated cycle between stimulation regimens. PMID:18982442
A wideband wireless neural stimulation platform for high-density microelectrode arrays.
Myers, Frank B; Simpson, Jim A; Ghovanloo, Maysam
2006-01-01
We describe a system that allows researchers to control an implantable neural microstimulator from a PC via a USB 2.0 interface and a novel dual-carrier wireless link, which provides separate data and power transmission. Our wireless stimulator, Interestim-2B (IS-2B), is a modular device capable of generating controlled-current stimulation pulse trains across 32 sites per module with support for a variety of stimulation schemes (biphasic/monophasic, bipolar/monopolar). We have developed software to generate multi-site stimulation commands for the IS-2B based on streaming data from artificial sensory devices such as cameras and microphones. For PC interfacing, we have developed a USB 2.0 microcontroller-based interface. Data is transmitted using frequency-shift keying (FSK) at 6/12 MHz to achieve a data rate of 3 Mb/s via a pair of rectangular coils. Power is generated using a class-E power amplifier operating at 1 MHz and transmitted via a separate pair of spiral planar coils which are oriented perpendicular to the data coils to minimize cross-coupling. We have successfully demonstrated the operation of the system by applying it as a visual prosthesis. Pulse-frequency modulated stimuli are generated in real-time based on a grayscale image from a webcam. These pulses are projected onto an 11x11 LED matrix that represents a 2D microelectrode array.
Liao, Xiang; Xing, Guoqiang; Guo, Zhiwei; Jin, Yu; Tang, Qing; He, Bin; McClure, Morgan A; Liu, Hua; Chen, Huaping; Mu, Qiwen
2017-03-01
A meta-analysis and systematic review was conducted to investigate the potential effects of repetitive transcranial magnetic stimulation on dysphagia in patients with stroke, including different parameters of frequency and stimulation site. PubMed, Embase, MEDLINE databases and the Cochrane Library, were searched for randomized controlled studies of repetitive transcranial magnetic stimulation treatment of dysphagia published before March 2016. Six clinical randomized controlled studies of a total of 163 stroke patients were included in this meta-analysis. A significant effect size of 1.24 was found for dysphagic outcome (mean effect size, 1.24; 95% confidence interval (CI), 0.67-1.81). A subgroup analysis based on frequency showed that the clinical scores were significantly improved in dysphagic patients with low frequency repetitive transcranial magnetic stimulation treatment ( P < 0.05) as well as high frequency repetitive transcranial magnetic stimulation treatment ( P < 0.05). A stimulation site stratified subgroup analysis implied significant changes in stroke patients with dysphagia for the unaffected hemisphere ( P < 0.05) and the bilateral hemisphere stimulation ( P < 0.05), but not for the affected hemisphere ( P > 0.05). The analysis of the follow-up data shows that patients in the repetitive transcranial magnetic stimulation groups still maintained the therapeutic benefit of repetitive transcranial magnetic stimulation four weeks after the last session of repetitive transcranial magnetic stimulation therapy ( P < 0.05). This meta-analysis indicates that repetitive transcranial magnetic stimulation has a positive effect on dysphagia after stroke. Compared with low-frequency repetitive transcranial magnetic stimulation, high-frequency repetitive transcranial magnetic stimulation may be more beneficial to the patients. This meta-analysis also supports that repetitive transcranial magnetic stimulation on an unaffected - or bilateral - hemisphere has a significant therapeutic effect on dysphagia.
Zeitooni, Mehrnaz; Mäki-Torkko, Elina; Stenfelt, Stefan
The purpose of this study is to evaluate binaural hearing ability in adults with normal hearing when bone conduction (BC) stimulation is bilaterally applied at the bone conduction hearing aid (BCHA) implant position as well as at the audiometric position on the mastoid. The results with BC stimulation are compared with bilateral air conduction (AC) stimulation through earphones. Binaural hearing ability is investigated with tests of spatial release from masking and binaural intelligibility level difference using sentence material, binaural masking level difference with tonal chirp stimulation, and precedence effect using noise stimulus. In all tests, results with bilateral BC stimulation at the BCHA position illustrate an ability to extract binaural cues similar to BC stimulation at the mastoid position. The binaural benefit is overall greater with AC stimulation than BC stimulation at both positions. The binaural benefit for BC stimulation at the mastoid and BCHA position is approximately half in terms of decibels compared with AC stimulation in the speech based tests (spatial release from masking and binaural intelligibility level difference). For binaural masking level difference, the binaural benefit for the two BC positions with chirp signal phase inversion is approximately twice the benefit with inverted phase of the noise. The precedence effect results with BC stimulation at the mastoid and BCHA position are similar for low frequency noise stimulation but differ with high-frequency noise stimulation. The results confirm that binaural hearing processing with bilateral BC stimulation at the mastoid position is also present at the BCHA implant position. This indicates the ability for binaural hearing in patients with good cochlear function when using bilateral BCHAs.
Contrast Enhancement for Thermal Acoustic Breast Cancer Imaging via Resonant Stimulation
2010-03-01
thermal acoustic signals tend to be weak. However, when the tumor is excited into resonance via EM stimulation, the effective acoustic scattering...the effective acoustic scattering cross-section may increase by a factor in excess of 100 based on predic tions for microsphere-based ultrasound...not apply, the heat conduction effects should be taken into consideration in calculating the pre ssure wave generated by electrom agnetic illum
Borsody, Mark K; Yamada, Chisa; Bielawski, Dawn; Heaton, Tamara; Castro Prado, Fernando; Garcia, Andrea; Azpiroz, Joaquín; Sacristan, Emilio
2014-04-01
Facial nerve stimulation has been proposed as a new treatment of ischemic stroke because autonomic components of the nerve dilate cerebral arteries and increase cerebral blood flow when activated. A noninvasive facial nerve stimulator device based on pulsed magnetic stimulation was tested in a dog middle cerebral artery occlusion model. We used an ischemic stroke dog model involving injection of autologous blood clot into the internal carotid artery that reliably embolizes to the middle cerebral artery. Thirty minutes after middle cerebral artery occlusion, the geniculate ganglion region of the facial nerve was stimulated for 5 minutes. Brain perfusion was measured using gadolinium-enhanced contrast MRI, and ATP and total phosphate levels were measured using 31P spectroscopy. Separately, a dog model of brain hemorrhage involving puncture of the intracranial internal carotid artery served as an initial examination of facial nerve stimulation safety. Facial nerve stimulation caused a significant improvement in perfusion in the hemisphere affected by ischemic stroke and a reduction in ischemic core volume in comparison to sham stimulation control. The ATP/total phosphate ratio showed a large decrease poststroke in the control group versus a normal level in the stimulation group. The same stimulation administered to dogs with brain hemorrhage did not cause hematoma enlargement. These results support the development and evaluation of a noninvasive facial nerve stimulator device as a treatment of ischemic stroke.
Qian, Jing-guang; Rong, Ke; Qian, Zhenyun; Wen, Chen; Zhang, Songning
2015-01-01
[Purpose] The purpose of the study was to design and implement a multichannel dynamic functional electrical stimulation system and investigate acute effects of functional electrical stimulation of the tibialis anterior and rectus femoris on ankle and knee sagittal-plane kinematics and related muscle forces of hemiplegic gait. [Subjects and Methods] A multichannel dynamic electrical stimulation system was developed with 8-channel low frequency current generators. Eight male hemiplegic patients were trained for 4 weeks with electric stimulation of the tibia anterior and rectus femoris muscles during walking, which was coupled with active contraction. Kinematic data were collected, and muscle forces of the tibialis anterior and rectus femoris of the affected limbs were analyzed using a musculoskelatal modeling approach before and after training. A paired sample t-test was used to detect the differences between before and after training. [Results] The step length of the affected limb significantly increased after the stimulation was applied. The maximum dorsiflexion angle and maximum knee flexion angle of the affected limb were both increased significantly during stimulation. The maximum muscle forces of both the tibia anterior and rectus femoris increased significantly during stimulation compared with before functional electrical stimulation was applied. [Conclusion] This study established a functional electrical stimulation strategy based on hemiplegic gait analysis and musculoskeletal modeling. The multichannel functional electrical stimulation system successfully corrected foot drop and altered circumduction hemiplegic gait pattern. PMID:26696734
Shi, Ying; Liang, Hua-Geng; Yang, Xiong; Hai, Bo; Wang, Liang; Xing, Yi-Fei; Ju, Wen; Zeng, Fu-Qing; Zhang, Xiao-Ping; Li, Wen-Cheng
2016-12-01
The safety and effectiveness of a novel Chinese one-shot dilation technique based on stimulated diuresis for percutaneous nephrolithotomy (PCNL) were investigated. After the feasibility of the Chinese one-shot dilation based on stimulated diuresis was verified by an animal study, this technique was applied in the clinical practice. A total of 67 patients in our department underwent the modified PCNL from July 2014 to June 2015. After the renal infundibulum was distended by stimulated diuresis, the kidney was punctured under the ultrasonographic guidance via the fornix of the target calyx. The working channel was dilated using a special designed pencil-shaped fascial dilator. The successful access rate, nephrostomy tract creation time, pre- and postoperative hemoglobin values and serum creatinine concentrations, stone-free rate and complications were recorded and analyzed. The renal infundibulum was successfully distended in all of the patients by the diuresis treatment. Under the ultrasonographic guidance, the successful access rate was 100% and the mean tract creation time was 2.0 min (range: 1.5-5.0 min). The stone-free rate right after surgery was 91.0%. Although the postoperative hemoglobin was significantly reduced (P<0.01), transfusion was not clinically necessary. There was no significant difference in serum creatinine concentrations before and after operation (P>0.05). No severe complication occurred during or after the PCNL. It was suggested that this Chinese one-shot dilation technique based on stimulated diuresis is an efficient and safe innovation for PCNL, and is even helpful for those patients with non-dilated pelvicaliceal systems.
NASA Astrophysics Data System (ADS)
Kang, Mijeong; Yoo, Seung Min; Gwak, Raekeun; Eom, Gayoung; Kim, Jihwan; Lee, Sang Yup; Kim, Bongsoo
2015-12-01
A sophisticated set of an Au nanowire (NW) stimulator-Au NW detector system is developed for electrical cell stimulation and electrochemical analysis of subsequent exocytosis with very high spatial resolution. Dopamine release from a rat pheochromocytoma cell is more stimulated by a more negative voltage pulse. This system could help to improve the therapeutic efficacy of electrotherapies by providing valuable information on their healing mechanism.A sophisticated set of an Au nanowire (NW) stimulator-Au NW detector system is developed for electrical cell stimulation and electrochemical analysis of subsequent exocytosis with very high spatial resolution. Dopamine release from a rat pheochromocytoma cell is more stimulated by a more negative voltage pulse. This system could help to improve the therapeutic efficacy of electrotherapies by providing valuable information on their healing mechanism. Electronic supplementary information (ESI) available. See DOI: 10.1039/c5nr06021d
Transcranial direct-current stimulation as treatment in epilepsy.
Gschwind, Markus; Seeck, Margitta
2016-12-01
Neuromodulation (NM) is a complementary therapy for patients with drug-resistant epilepsy. Vagal nerve stimulation and deep brain stimulation of the anterior thalamus are established techniques and have shown their efficacy in lowering seizure frequency, but they are invasive and rarely render patients seizure-free. Non-invasive NM techniques are therefore increasingly investigated in a clinical context. Areas covered: Current knowledge about transcranial direct-current stimulation (tDCS) and other non-invasive NM in patients with epilepsy, based on the available animal and clinical studies from PubMed search. Expert commentary: tDCS modulates neuronal membrane potentials, and consequently alters cortical excitability. Cathodal stimulation leads to cortical inhibition, which is of particular importance in epilepsy treatment. The antiepileptic efficacy is promising but still lacks systematic studies. The beneficial effect, seen in ~20%, outlasts the duration of stimulation, indicating neuronal plasticity and is therefore of great interest to obtain long-term effects.
A new bio-inspired stimulator to suppress hyper-synchronized neural firing in a cortical network.
Amiri, Masoud; Amiri, Mahmood; Nazari, Soheila; Faez, Karim
2016-12-07
Hyper-synchronous neural oscillations are the character of several neurological diseases such as epilepsy. On the other hand, glial cells and particularly astrocytes can influence neural synchronization. Therefore, based on the recent researches, a new bio-inspired stimulator is proposed which basically is a dynamical model of the astrocyte biophysical model. The performance of the new stimulator is investigated on a large-scale, cortical network. Both excitatory and inhibitory synapses are also considered in the simulated spiking neural network. The simulation results show that the new stimulator has a good performance and is able to reduce recurrent abnormal excitability which in turn avoids the hyper-synchronous neural firing in the spiking neural network. In this way, the proposed stimulator has a demand controlled characteristic and is a good candidate for deep brain stimulation (DBS) technique to successfully suppress the neural hyper-synchronization. Copyright © 2016 Elsevier Ltd. All rights reserved.
Lafaurie, Gloria; Fedele, Stefano; López, Rafael Martín-Granizo; Wolff, Andy; Strietzel, Frank; Porter, Stephen R; Konttinen, Yrjö T
2009-02-01
Treatment of xerostomia is a common clinical challenge in the oral medicine practice. Although some treatments have been used to improve the symptoms of xerostomia, none is completely satisfactory for the patients who suffer of this alteration. In the last years non-pharmacological treatments based on electro-stimulation for the treatment of xerostomia have been developed. This review is aimed at presenting new developments for the treatment of xerostomia, applying neuro-electro-stimulation by miniaturized intra-oral electro-stimulators. These devices increase salivary secretion and improve symptoms of oral dryness. Their effect is obtained by means of stimulation of the lingual nerve, in whose proximity the electrodes of the apparatus are placed. The objective of this mechanism is both to directly stimulate the salivary glands controlled by that nerve and to enhance the salivary reflex. Clinical studies have been carried out that have demonstrated the wetting effect of the method described in this article.
Undergraduate Prescription Stimulant Misuse: The Impact of Academic Strain.
Norman, Lauren; Ford, Jason
2018-01-09
This study investigated the misuse of prescription stimulants among undergraduates for academic purposes. This research is important as existing literature has indicated that this type of prescription drug misuse is a growing concern, especially among college undergraduates aged 18-25. This study focused on how various types of academic strain (i.e., academic strain, grade strain, and academic impediments) influenced the misuse of prescription stimulants. Roughly 900 quantitative surveys were collected at a large Southeastern university in May 2014 that specifically addressed prescription stimulant misuse. Results from regression analyses indicated that college students are at an increased likelihood of misusing prescription stimulants for academic purposes if they experienced academic impediments and/or grade strain during the past academic year. Conclusions/Importance: It is necessary to identify how academic strain impacts undergraduates' likelihood of engaging in the misuse of prescription stimulants as this information may aid in college based educational and prevention programs.
Verticality perception during and after galvanic vestibular stimulation.
Volkening, Katharina; Bergmann, Jeannine; Keller, Ingo; Wuehr, Max; Müller, Friedemann; Jahn, Klaus
2014-10-03
The human brain constructs verticality perception by integrating vestibular, somatosensory, and visual information. Here we investigated whether galvanic vestibular stimulation (GVS) has an effect on verticality perception both during and after application, by assessing the subjective verticals (visual, haptic and postural) in healthy subjects at those times. During stimulation the subjective visual vertical and the subjective haptic vertical shifted towards the anode, whereas this shift was reversed towards the cathode in all modalities once stimulation was turned off. Overall, the effects were strongest for the haptic modality. Additional investigation of the time course of GVS-induced changes in the haptic vertical revealed that anodal shifts persisted for the entire 20-min stimulation interval in the majority of subjects. Aftereffects exhibited different types of decay, with a preponderance for an exponential decay. The existence of such reverse effects after stimulation could have implications for GVS-based therapy. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Bau, V; Rose, K; Pollack, K; Spoerl, E; Pillunat, L E
2012-10-01
The studies of Kämpf et al. suggested an efficiency of a computer-based stimulation therapy by drifting sinus gratings in patients with anisometropic and/or strabismic amblyopia but provided no clear evidence. This is the first trial with amblyopic patients without previous treatment at the beginning of amblyopia therapy. A prospective, randomised, single-blinded, placebo-controlled study of n = 15 patients with anisometropic and/or strabismic amblyopia without previous treatment was performed. Age of the patients was between 4 and 10 years, mean 6.3 years (± 2.0), all after full correction of refraction errors and refractive adaptation. Stimulation therapy was performed 5 times a week over 4 weeks, respectively 2 × 20 min, a drifting sinus grating of constant spatial and temporal frequency was combined with computer games (n = 8). Control group had only computer games with a neutral background (n = 7). In both groups patching was only done in stimulation times. Stimulation and control group did not differ due to age, gender, and cause of amblyopie, baseline visual acuity, and time of wearing glasses. There was no significant difference in the development of visual acuity over the stimulation period between stimulation and control groups. Stimulation therapy with drifting sinus gratings did not improve the development of visual acuity in the first phase of amblyopia treatment combined with minimal occlusion therapy. Accordingly, the stimulation therapy is not adequate to replace sufficient occlusion therapy. Whether this therapy could support patching therapy and improve acuity development in later therapy phases cannot be assumed from this trial. Georg Thieme Verlag KG Stuttgart · New York.
NASA Astrophysics Data System (ADS)
Yeung, Sai Ho; Pradhan, Raunaq; Feng, Xiaohua; Zheng, Yuanjin
2015-09-01
Recently, the design concept of magnetic resonant coupling has been adapted to electromagnetic therapy applications such as non-invasive radiofrequency (RF) stimulation. This technique can significantly increase the electric field radiated from the magnetic coil at the stimulation target, and hence enhancing the current flowing through the nerve, thus enabling stimulation. In this paper, the developed magnetic resonant coupling (MRC) stimulation, magnetic stimulation (MS) and transcutaneous electrical nerve stimulation (TENS) are compared. The differences between the MRC RF stimulation and other techniques are presented in terms of the operating mechanism, ex-vivo tissue voltage measurement and electromagnetic simulation analysis. The ev-vivo tissue voltage measurement experiment is performed on the compared devices based on measuring the voltage induced by electromagnetic induction at the tissue. The focusing effect, E field and voltage induced across the tissue, and the attenuation due to the increase of separation between the coil and the target are analyzed. The electromagnetic stimulation will also be performed to obtain the electric field and magnetic field distribution around the biological medium. The electric field intensity is proportional to the induced current and the magnetic field is corresponding to the electromagnetic induction across the biological medium. The comparison between the MRC RF stimulator and the MS and TENS devices revealed that the MRC RF stimulator has several advantages over the others for the applications of inducing current in the biological medium for stimulation purposes.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yeung, Sai Ho; Pradhan, Raunaq; Feng, Xiaohua
Recently, the design concept of magnetic resonant coupling has been adapted to electromagnetic therapy applications such as non-invasive radiofrequency (RF) stimulation. This technique can significantly increase the electric field radiated from the magnetic coil at the stimulation target, and hence enhancing the current flowing through the nerve, thus enabling stimulation. In this paper, the developed magnetic resonant coupling (MRC) stimulation, magnetic stimulation (MS) and transcutaneous electrical nerve stimulation (TENS) are compared. The differences between the MRC RF stimulation and other techniques are presented in terms of the operating mechanism, ex-vivo tissue voltage measurement and electromagnetic simulation analysis. The ev-vivo tissuemore » voltage measurement experiment is performed on the compared devices based on measuring the voltage induced by electromagnetic induction at the tissue. The focusing effect, E field and voltage induced across the tissue, and the attenuation due to the increase of separation between the coil and the target are analyzed. The electromagnetic stimulation will also be performed to obtain the electric field and magnetic field distribution around the biological medium. The electric field intensity is proportional to the induced current and the magnetic field is corresponding to the electromagnetic induction across the biological medium. The comparison between the MRC RF stimulator and the MS and TENS devices revealed that the MRC RF stimulator has several advantages over the others for the applications of inducing current in the biological medium for stimulation purposes.« less
NASA Astrophysics Data System (ADS)
Yazdan-Shahmorad, A.; Lehmkuhle, M. J.; Gage, G. J.; Marzullo, T. C.; Parikh, H.; Miriani, R. M.; Kipke, D. R.
2011-08-01
While the development of microelectrode arrays has enabled access to disparate regions of a cortex for neurorehabilitation, neuroprosthetic and basic neuroscience research, accurate interpretation of the signals and manipulation of the cortical neurons depend upon the anatomical placement of the electrode arrays in a layered cortex. Toward this end, this report compares two in vivo methods for identifying the placement of electrodes in a linear array spaced 100 µm apart based on in situ laminar analysis of (1) ketamine-xylazine-induced field potential oscillations in a rat motor cortex and (2) an intracortical electrical stimulation-induced movement threshold. The first method is based on finding the polarity reversal in laminar oscillations which is reported to appear at the transition between layers IV and V in laminar 'high voltage spindles' of the rat cortical column. Analysis of histological images in our dataset indicates that polarity reversal is detected 150.1 ± 104.2 µm below the start of layer V. The second method compares the intracortical microstimulation currents that elicit a physical movement for anodic versus cathodic stimulation. It is based on the hypothesis that neural elements perpendicular to the electrode surface are preferentially excited by anodic stimulation while cathodic stimulation excites those with a direction component parallel to its surface. With this method, we expect to see a change in the stimulation currents that elicits a movement at the beginning of layer V when comparing anodic versus cathodic stimulation as the upper cortical layers contain neuronal structures that are primarily parallel to the cortical surface and lower layers contain structures that are primarily perpendicular. Using this method, there was a 78.7 ± 68 µm offset in the estimate of the depth of the start of layer V. The polarity reversal method estimates the beginning of layer V within ±90 µm with 95% confidence and the intracortical stimulation method estimates it within ±69.3 µm. We propose that these methods can be used to estimate the in situ location of laminar electrodes implanted in the rat motor cortex.
Jochumsen, Mads; Signal, Nada; Nedergaard, Rasmus W.; Taylor, Denise; Haavik, Heidi; Niazi, Imran K.
2015-01-01
Long-term depression (LTD) and long-term potentiation (LTP)-like plasticity are models of synaptic plasticity which have been associated with memory and learning. The induction of LTD and LTP-like plasticity, using different stimulation protocols, has been proposed as a means of addressing abnormalities in cortical excitability associated with conditions such as focal hand dystonia and stroke. The aim of this study was to investigate whether the excitability of the cortical projections to the tibialis anterior (TA) muscle could be decreased when dorsiflexion of the ankle joint was imagined and paired with peripheral electrical stimulation (ES) of the nerve supplying the antagonist soleus muscle. The effect of stimulus timing was evaluated by comparing paired stimulation timed to reach the cortex before, at and after the onset of imagined movement. Fourteen healthy subjects participated in six experimental sessions held on non-consecutive days. The timing of stimulation delivery was determined offline based on the contingent negative variation (CNV) of electroencephalography brain data obtained during imagined dorsiflexion. Afferent stimulation was provided via a single pulse ES to the peripheral nerve paired, based on the CNV, with motor imagination of ankle dorsiflexion. A significant decrease (P = 0.001) in the excitability of the cortical projection of TA was observed when the afferent volley from the ES of the tibial nerve (TN) reached the cortex at the onset of motor imagination based on the CNV. When TN stimulation was delivered before (P = 0.62), or after (P = 0.23) imagined movement onset there was no significant effect. Nor was a significant effect found when ES of the TN was applied independent of imagined movement (P = 0.45). Therefore, the excitability of the cortical projection to a muscle can be inhibited when ES of the nerve supplying the antagonist muscle is precisely paired with the onset of imagined movement. PMID:26648859
Jochumsen, Mads; Signal, Nada; Nedergaard, Rasmus W; Taylor, Denise; Haavik, Heidi; Niazi, Imran K
2015-01-01
Long-term depression (LTD) and long-term potentiation (LTP)-like plasticity are models of synaptic plasticity which have been associated with memory and learning. The induction of LTD and LTP-like plasticity, using different stimulation protocols, has been proposed as a means of addressing abnormalities in cortical excitability associated with conditions such as focal hand dystonia and stroke. The aim of this study was to investigate whether the excitability of the cortical projections to the tibialis anterior (TA) muscle could be decreased when dorsiflexion of the ankle joint was imagined and paired with peripheral electrical stimulation (ES) of the nerve supplying the antagonist soleus muscle. The effect of stimulus timing was evaluated by comparing paired stimulation timed to reach the cortex before, at and after the onset of imagined movement. Fourteen healthy subjects participated in six experimental sessions held on non-consecutive days. The timing of stimulation delivery was determined offline based on the contingent negative variation (CNV) of electroencephalography brain data obtained during imagined dorsiflexion. Afferent stimulation was provided via a single pulse ES to the peripheral nerve paired, based on the CNV, with motor imagination of ankle dorsiflexion. A significant decrease (P = 0.001) in the excitability of the cortical projection of TA was observed when the afferent volley from the ES of the tibial nerve (TN) reached the cortex at the onset of motor imagination based on the CNV. When TN stimulation was delivered before (P = 0.62), or after (P = 0.23) imagined movement onset there was no significant effect. Nor was a significant effect found when ES of the TN was applied independent of imagined movement (P = 0.45). Therefore, the excitability of the cortical projection to a muscle can be inhibited when ES of the nerve supplying the antagonist muscle is precisely paired with the onset of imagined movement.
Endothelial Progenitor Cells as Shuttle of Anticancer Agents.
Laurenzana, Anna; Margheri, Francesca; Chillà, Anastasia; Biagioni, Alessio; Margheri, Giancarlo; Calorini, Lido; Fibbi, Gabriella; Del Rosso, Mario
2016-10-01
Cell therapies are treatments in which stem or progenitor cells are stimulated to differentiate into specialized cells able to home to and repair damaged tissues. After their discovery, endothelial progenitor cells (EPCs) stimulated worldwide interest as possible vehicles to perform autologous cell therapy of tumors. Taking into account the tumor-homing properties of EPCs, two different approaches to control cancer progression have been pursued by combining cell-based therapy with gene therapy or with nanomedicine. The first approach is based on the possibility of engineering EPCs to express different transgenes, and the second is based on the capacity of EPCs to take up nanomaterials. Here we review the most important progress covering the following issues: the characterization of bona fide endothelial progenitor cells, their role in tumor vascularization and metastasis, and preclinical data about their use in cell-based tumor therapy, considering antiangiogenic, suicide, immune-stimulating, and oncolytic virus gene therapy. The mixed approach of EPC cell therapy and nanomedicine is discussed in terms of plasmonic-dependent thermoablation and molecular imaging.
Gibson, William S.; Jo, Hang Joon; Testini, Paola; Cho, Shinho; Felmlee, Joel P.; Welker, Kirk M.; Klassen, Bryan T.; Min, Hoon-Ki
2016-01-01
Deep brain stimulation is an established neurosurgical therapy for movement disorders including essential tremor and Parkinson’s disease. While typically highly effective, deep brain stimulation can sometimes yield suboptimal therapeutic benefit and can cause adverse effects. In this study, we tested the hypothesis that intraoperative functional magnetic resonance imaging could be used to detect deep brain stimulation-evoked changes in functional and effective connectivity that would correlate with the therapeutic and adverse effects of stimulation. Ten patients receiving deep brain stimulation of the ventralis intermedius thalamic nucleus for essential tremor underwent functional magnetic resonance imaging during stimulation applied at a series of stimulation localizations, followed by evaluation of deep brain stimulation-evoked therapeutic and adverse effects. Correlations between the therapeutic effectiveness of deep brain stimulation (3 months postoperatively) and deep brain stimulation-evoked changes in functional and effective connectivity were assessed using region of interest-based correlation analysis and dynamic causal modelling, respectively. Further, we investigated whether brain regions might exist in which activation resulting from deep brain stimulation might correlate with the presence of paraesthesias, the most common deep brain stimulation-evoked adverse effect. Thalamic deep brain stimulation resulted in activation within established nodes of the tremor circuit: sensorimotor cortex, thalamus, contralateral cerebellar cortex and deep cerebellar nuclei (FDR q < 0.05). Stimulation-evoked activation in all these regions of interest, as well as activation within the supplementary motor area, brainstem, and inferior frontal gyrus, exhibited significant correlations with the long-term therapeutic effectiveness of deep brain stimulation (P < 0.05), with the strongest correlation (P < 0.001) observed within the contralateral cerebellum. Dynamic causal modelling revealed a correlation between therapeutic effectiveness and attenuated within-region inhibitory connectivity in cerebellum. Finally, specific subregions of sensorimotor cortex were identified in which deep brain stimulation-evoked activation correlated with the presence of unwanted paraesthesias. These results suggest that thalamic deep brain stimulation in tremor likely exerts its effects through modulation of both olivocerebellar and thalamocortical circuits. In addition, our findings indicate that deep brain stimulation-evoked functional activation maps obtained intraoperatively may contain predictive information pertaining to the therapeutic and adverse effects induced by deep brain stimulation. PMID:27329768
Samani, Mohsen Mosayebi; Mahnam, Amin; Hosseini, Nasrin
2014-04-01
Portable wireless neuro-stimulators have been developed to facilitate long-term cognitive and behavioral studies on the central nervous system in freely moving animals. These stimulators can provide precisely controllable input(s) to the nervous system, without distracting the animal attention with cables connected to its body. In this study, a low power backpack neuro-stimulator was developed for animal brain researches that can provides arbitrary stimulus waveforms for the stimulation, while it is small and light weight to be used for small animals including rats. The system consists of a controller that uses an RF link to program and activate a small and light microprocessor-based stimulator. A Howland current source was implemented to produce precise current controlled arbitrary waveform stimulations. The system was optimized for ultra-low power consumption and small size. The stimulator was first tested for its electrical specifications. Then its performance was evaluated in a rat experiment when electrical stimulation of medial longitudinal fasciculus induced circling behavior. The stimulator is capable of delivering programmed stimulations up to ± 2 mA with adjusting steps of 1 μA, accuracy of 0.7% and compliance of 6 V. The stimulator is 15 mm × 20 mm × 40 mm in size, weights 13.5 g without battery and consumes a total power of only 5.l mW. In the experiment, the rat could easily carry the stimulator and demonstrated the circling behavior for 0.1 ms current pulses of above 400 μA. The developed system has a competitive size and weight, whereas providing a wide range of operation and the flexibility of generating arbitrary stimulation patterns ideal for long-term experiments in the field of cognitive and neuroscience research.
Grossöhmichen, Martin; Salcher, Rolf; Kreipe, Hans-Heinrich; Lenarz, Thomas; Maier, Hannes
2015-01-01
This work assesses the efficiency of the Codacs system actuator (Cochlear Ltd., Sydney Australia) in different inner ear stimulation modalities. Originally the actuator was intended for direct perilymph stimulation after stapedotomy using a piston prosthesis. A possible alternative application is the stimulation of middle ear structures or the round window (RW). Here the perilymph stimulation with a K-piston through a stapes footplate (SFP) fenestration (N = 10) as well as stimulation of the stapes head (SH) with a Bell prosthesis (N = 9), SFP stimulation with an Omega/Aerial prosthesis (N = 8) and reverse RW stimulation (N = 10) were performed in cadaveric human temporal bones (TBs). Codacs actuator output is expressed as equivalent sound pressure level (eq. SPL) using RW and SFP displacement responses, measured by Laser Doppler velocimetry as reference. The axial actuator coupling force in stimulation of stapes and RW was adjusted to ~ 5 mN. The Bell prosthesis and Omega/Aerial prosthesis stimulation generated similar mean eq. SPLs (Bell: 127.5–141.8 eq. dB SPL; Omega/Aerial: 123.6–143.9 eq. dB SPL), being significantly more efficient than K-piston perilymph stimulation (108.6–131.6 eq. dB SPL) and RW stimulation (108.3–128.2 eq. dB SPL). Our results demonstrate that SH, SFP and RW are adequate alternative stimulation sites for the Codacs actuator using coupling prostheses and an axial coupling force of ~ 5 mN. Based on the eq. SPLs, all investigated methods were adequate for in vivo hearing aid applications, provided that experimental conditions including constant coupling force will be implemented. PMID:25785860
Sidtis, John J; Tagliati, Michele; Alterman, Ron; Sidtis, Diana; Dhawan, Vijay; Eidelberg, David
2012-01-01
Chronic, high-frequency electrical stimulation of the subthalamic nuclei (STNs) has become an effective and widely used therapy in Parkinson's disease (PD), but the therapeutic mechanism is not understood. Stimulation of the STN is believed to reorganize neurophysiological activity patterns within the basal ganglia, whereas local field effects extending to tracts adjacent to the STN are viewed as sources of nontherapeutic side effects. This study is part of a larger project investigating the effects of STN stimulation on speech and regional cerebral blood flow (CBF) in human subjects with PD. While generating measures of global CBF (gCBF) to normalize regional CBF values for a subsequent combined analysis of regional CBF and speech data, we observed a third effect of this therapy: a gCBF increase. This effect was present across three estimates of gCBF ranging from values based on the highest activity voxels to those based on all voxels. The magnitude of the gCBF increase was related to the subject's duration of PD. It is not clear whether this CBF effect has a therapeutic role, but the impact of deep brain stimulation on cerebrovascular control warrants study from neuroscience, pathophysiological, and therapeutic perspectives.
Ruffini, Giulio; Fox, Michael D.; Ripolles, Oscar; Miranda, Pedro Cavaleiro; Pascual-Leone, Alvaro
2014-01-01
Recently, multifocal transcranial current stimulation (tCS) devices using several relatively small electrodes have been used to achieve more focal stimulation of specific cortical targets. However, it is becoming increasingly recognized that many behavioral manifestations of neurological and psychiatric disease are not solely the result of abnormality in one isolated brain region but represent alterations in brain networks. In this paper we describe a method for optimizing the configuration of multifocal tCS for stimulation of brain networks, represented by spatially extended cortical targets. We show how, based on fMRI, PET, EEG or other data specifying a target map on the cortical surface for excitatory, inhibitory or neutral stimulation and a constraint of the maximal number of electrodes, a solution can be produced with the optimal currents and locations of the electrodes. The method described here relies on a fast calculation of multifocal tCS electric fields (including components normal and tangential to the cortical boundaries) using a five layer finite element model of a realistic head. Based on the hypothesis that the effects of current stimulation are to first order due to the interaction of electric fields with populations of elongated cortical neurons, it is argued that the optimization problem for tCS stimulation can be defined in terms of the component of the electric field normal to the cortical surface. Solutions are found using constrained least squares to optimize current intensities, while electrode number and their locations are selected using a genetic algorithm. For direct current tCS (tDCS) applications, we provide some examples of this technique using an available tCS system providing 8 small Ag/AgCl stimulation electrodes. We demonstrate the approach both for localized and spatially extended targets defined using rs-fcMRI and PET data, with clinical applications in stroke and depression. Finally, we extend these ideas to more general stimulation protocols, such as alternating current tCS (tACS). PMID:24345389
Randomized controlled trial of home-based 4-week tDCS in chronic minimally conscious state.
Martens, Géraldine; Lejeune, Nicolas; O'Brien, Anthony Terrence; Fregni, Felipe; Martial, Charlotte; Wannez, Sarah; Laureys, Steven; Thibaut, Aurore
2018-05-02
Patients with chronic disorders of consciousness face a significant lack of treatment options. We aimed at investigating the feasibility and the behavioral effects of home-based transcranial direct current stimulation (tDCS), applied by relatives or caregivers, in chronic patients in minimally conscious state (MCS). Each participant received, in a randomized order, 20 sessions of active and 20 sessions of sham tDCS applied over the prefrontal cortex for 4 weeks; separated by 8 weeks of washout. Level of consciousness was assessed using the Coma Recovery Scale-Revised before the first stimulation (baseline), at the end of the 20 tDCS sessions (direct effects) and 8 weeks after the end of each stimulation period (long-term effects). Reported adverse events and data relative to the adherence (i.e., amount of sessions effectively received) were collected as well. Twenty-seven patients completed the study and 22 patients received at least 80% of the stimulation sessions. All patients tolerated tDCS well, no severe adverse events were noticed after real stimulation and the overall adherence (i.e., total duration of stimulation) was good. A moderate effect size (0.47 and 0.53, for modified intention to treat and per protocol analysis, respectively) was observed at the end of the 4 weeks of tDCS in favor of the active treatment. We demonstrated that home-based tDCS can be used adequately outside a research facility or hospital by patients' relatives or caregivers. In addition, 4 weeks of tDCS moderately improved the recovery of signs of consciousness in chronic MCS patients. Copyright © 2018 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Deprez, Hanne; Gransier, Robin; Hofmann, Michael; van Wieringen, Astrid; Wouters, Jan; Moonen, Marc
2018-02-01
Objective. Electrically evoked auditory steady-state responses (EASSRs) are potentially useful for objective cochlear implant (CI) fitting and follow-up of the auditory maturation in infants and children with a CI. EASSRs are recorded in the electro-encephalogram (EEG) in response to electrical stimulation with continuous pulse trains, and are distorted by significant CI artifacts related to this electrical stimulation. The aim of this study is to evaluate a CI artifacts attenuation method based on independent component analysis (ICA) for three EASSR datasets. Approach. ICA has often been used to remove CI artifacts from the EEG to record transient auditory responses, such as cortical evoked auditory potentials. Independent components (ICs) corresponding to CI artifacts are then often manually identified. In this study, an ICA based CI artifacts attenuation method was developed and evaluated for EASSR measurements with varying CI artifacts and EASSR characteristics. Artifactual ICs were automatically identified based on their spectrum. Main results. For 40 Hz amplitude modulation (AM) stimulation at comfort level, in high SNR recordings, ICA succeeded in removing CI artifacts from all recording channels, without distorting the EASSR. For lower SNR recordings, with 40 Hz AM stimulation at lower levels, or 90 Hz AM stimulation, ICA either distorted the EASSR or could not remove all CI artifacts in most subjects, except for two of the seven subjects tested with low level 40 Hz AM stimulation. Noise levels were reduced after ICA was applied, and up to 29 ICs were rejected, suggesting poor ICA separation quality. Significance. We hypothesize that ICA is capable of separating CI artifacts and EASSR in case the contralateral hemisphere is EASSR dominated. For small EASSRs or large CI artifact amplitudes, ICA separation quality is insufficient to ensure complete CI artifacts attenuation without EASSR distortion.
Nahar, B; Hossain, M I; Hamadani, J D; Ahmed, T; Huda, S N; Grantham-McGregor, S M; Persson, L A
2012-06-01
Psychosocial stimulation (PS) and food supplementation (FS) improve development of malnourished children. This study evaluates the effects of a community-based approach of PS and FS on growth and development of severely malnourished children. Severely underweight hospitalised children aged 6-24 months (n = 507) were randomly allocated on discharge to five groups: (i) PS, (ii) FS, (iii) PS+FS, (iv) clinic-control and (v) hospital-control. PS included play sessions and parental counselling on child development. This was done at each fortnightly follow-up visit, that is, every second week, for 6 months at community clinics. FS included distribution of cereal-based food packets (150-300 kcal/day) for 3 months. All groups received medical care, micronutrient supplementation, health-education and growth monitoring. Children's development was assessed using revised version of Bayley Scales of Infant Development at baseline and after 3 and 6 months of intervention. Anthropometry was measured using standard procedure. Comparing groups with any stimulation with those with no stimulation there was a significant effect of stimulation on children's mental development index (group*session interaction P = 0.037, effect size = 0.37 s.d.) and weight-for-age Z-score (group*session interaction P = 0.02, effect size=0.26 s.d.). Poor levels of development and nutritional status were sustained, however, due to their initial very severe malnutrition. There was no effect on motor development and linear growth. Children receiving any stimulation showed a significant benefit to mental development and growth in weight. More intensive intervention with longer duration is needed to correct their poor developmental levels and nutritional status.
NASA Astrophysics Data System (ADS)
Guo, Rui; Liu, Jing
2017-10-01
With significant advantages in rapidly restoring the nerve function, electrical stimulation of nervous tissue is a crucial treatment of peripheral nerve injuries leading to common movement disorder. However, the currently available stimulating electrodes generally based on rigid conductive materials would cause a potential mechanical mismatch with soft neural tissues which thus reduces long-term effects of electrical stimulation. Here, we proposed and fabricated a flexible neural microelectrode array system based on the liquid metal GaIn alloy (75.5% Ga and 24.5% In by weight) and via printing approach. Such an alloy with a unique low melting point (10.35 °C) owns excellent electrical conductivity and high compliance, which are beneficial to serve as implantable flexible neural electrodes. The flexible neural microelectrode array embeds four liquid metal electrodes and stretchable interconnects in a PDMS membrane (500 µm in thickness) that possess a lower elastic modulus (1.055 MPa), which is similar to neural tissues with elastic moduli in the 0.1-1.5 MPa range. The electrical experiments indicate that the liquid metal interconnects could sustain over 7000 mechanical stretch cycles with resistance approximately staying at 4 Ω. Over the conceptual experiments on animal sciatic nerve electrical stimulation, the dead bullfrog implanted with flexible neural microelectrode array could even rhythmically contract and move its lower limbs under the electrical stimulations from the implant. This demonstrates a highly efficient way for quickly recovering biological nerve functions. Further, the good biocompatibility of the liquid metal material was justified via a series of biological experiments. This liquid metal modality for neural stimulation is expected to play important roles as biologic electrodes to overcome the fundamental mismatch in mechanics between biological tissues and electronic devices in the coming time.
Turon, Marc; Fernandez-Gonzalo, Sol; Jodar, Mercè; Gomà, Gemma; Montanya, Jaume; Hernando, David; Bailón, Raquel; de Haro, Candelaria; Gomez-Simon, Victor; Lopez-Aguilar, Josefina; Magrans, Rudys; Martinez-Perez, Melcior; Oliva, Joan Carles; Blanch, Lluís
2017-12-01
Growing evidence suggests that critical illness often results in significant long-term neurocognitive impairments in one-third of survivors. Although these neurocognitive impairments are long-lasting and devastating for survivors, rehabilitation rarely occurs during or after critical illness. Our aim is to describe an early neurocognitive stimulation intervention based on virtual reality for patients who are critically ill and to present the results of a proof-of-concept study testing the feasibility, safety, and suitability of this intervention. Twenty critically ill adult patients undergoing or having undergone mechanical ventilation for ≥24 h received daily 20-min neurocognitive stimulation sessions when awake and alert during their ICU stay. The difficulty of the exercises included in the sessions progressively increased over successive sessions. Physiological data were recorded before, during, and after each session. Safety was assessed through heart rate, peripheral oxygen saturation, and respiratory rate. Heart rate variability analysis, an indirect measure of autonomic activity sensitive to cognitive demands, was used to assess the efficacy of the exercises in stimulating attention and working memory. Patients successfully completed the sessions on most days. No sessions were stopped early for safety concerns, and no adverse events occurred. Heart rate variability analysis showed that the exercises stimulated attention and working memory. Critically ill patients considered the sessions enjoyable and relaxing without being overly fatiguing. The results in this proof-of-concept study suggest that a virtual-reality-based neurocognitive intervention is feasible, safe, and tolerable, stimulating cognitive functions and satisfying critically ill patients. Future studies will evaluate the impact of interventions on neurocognitive outcomes. Trial registration Clinical trials.gov identifier: NCT02078206.
2015-09-01
Award Number: W81XWH-11-1-0384 TITLE: Evaluation of Immune Responses Mediated by Listeria-Stimulated Human Dendritic Cells : Implications for...Immune Responses Mediated by Listeria-Stimulated Human Dendritic Cells : Implications for Cancer Vaccine Therapy 5b. GRANT NUMBER CA100463 5c...Listeria monocytogenes (Lm) on human dendritic cells (DCs) to optimize Lm-based DC cancer vaccines. The project aims are: 1) Compare the activation and
Palatoglossus coupling in selective upper airway stimulation.
Heiser, Clemens; Edenharter, Günther; Bas, Murat; Wirth, Markus; Hofauer, Benedikt
2017-10-01
Selective upper airway stimulation (sUAS) of the hypoglossal nerve is a useful therapy to treat patients with obstructive sleep apnea. Is it known that multiple obstructions can be solved by this stimulation technique, even at the retropalatal region. The aim of this study was to verify the palatoglossus coupling at the soft palate during stimulation. Single-center, prospective clinical trail. Twenty patients who received an sUAS implant from April 2015 to April 2016 were included. A drug-induced sedated endoscopy (DISE) was performed before surgery. Six to 12 months after activation of the system, patients' tongue motions were recorded, an awake transnasal endoscopy was performed with stimulation turned on, and a DISE with stimulation off and on was done. Patients with a bilateral protrusion of the tongue base showed a significantly increased opening at the retropalatal level compared to ipsilateral protrusions. Furthermore, patients with a clear activation of the geniohyoid muscle showed a better reduction in apnea-hypopnea index. A bilateral protrusion of the tongue base during sUAS seems to be accompanied with a better opening of the soft palate. This effect can be explained by the palatoglossal coupling, due to its linkage of the muscles within the soft palate to those of the lateral tongue body. 4 Laryngoscope, 127:E378-E383, 2017. © 2017 The American Laryngological, Rhinological and Otological Society, Inc.
Energy-optimal electrical excitation of nerve fibers.
Jezernik, Saso; Morari, Manfred
2005-04-01
We derive, based on an analytical nerve membrane model and optimal control theory of dynamical systems, an energy-optimal stimulation current waveform for electrical excitation of nerve fibers. Optimal stimulation waveforms for nonleaky and leaky membranes are calculated. The case with a leaky membrane is a realistic case. Finally, we compare the waveforms and energies necessary for excitation of a leaky membrane in the case where the stimulation waveform is a square-wave current pulse, and in the case of energy-optimal stimulation. The optimal stimulation waveform is an exponentially rising waveform and necessitates considerably less energy to excite the nerve than a square-wave pulse (especially true for larger pulse durations). The described theoretical results can lead to drastically increased battery lifetime and/or decreased energy transmission requirements for implanted biomedical systems.
A Mobile Early Stimulation Program to Support Children with Developmental Delays in Brazil.
Dias, Raquel da Luz; Silva, Kátia Cristina Correa Guimarães; Lima, Marcela Raquel de Oliveira; Alves, João Guilherme Bezerra; Abidi, Syed Sibte Raza
2018-01-01
Developmental delay is a deviation development from the normative milestones during the childhood and it may be caused by neurological disorders. Early stimulation is a standardized and simple technique to treat developmental delays in children (aged 0-3 years), allowing them to reach the best development possible and to mitigate neuropsychomotor sequelae. However, the outcomes of the treatment depending on the involvement of the family, to continue the activities at home on a daily basis. To empower and educate parents of children with neurodevelopmental delays to administer standardized early stimulation programs at home, we developed a mobile early stimulation program that provides timely and evidence-based clinical decision support to health professionals and a personalized guidance to parents about how to administer early stimulation to their child at home.
Transcranial magnetic stimulation assisted by neuronavigation of magnetic resonance images
NASA Astrophysics Data System (ADS)
Viesca, N. Angeline; Alcauter, S. Sarael; Barrios, A. Fernando; González, O. Jorge J.; Márquez, F. Jorge A.
2012-10-01
Technological advance has improved the way scientists and doctors can learn about the brain and treat different disorders. A non-invasive method used for this is Transcranial Magnetic Stimulation (TMS) based on neuron excitation by electromagnetic induction. Combining this method with functional Magnetic Resonance Images (fMRI), it is intended to improve the localization technique of cortical brain structures by designing an extracranial localization system, based on Alcauter et al. work.
Phorbol ester stimulates calcium sequestration in saponized human platelets
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yoshida, K.; Nachmias, V.T.
1987-11-25
When platelets are activated by agonists, calcium (Ca2+) is released from an intracellular storage site. Recent studies using fura-2 show that, after thrombin stimulation, the rise in free calcium is transient and returns to base-line levels in 2-3 min, while the transient following ADP stimulation lasts only 15-20 s. We reported previously that the phorbol ester 12,13-phorbol myristate acetate (PMA), added at nanomolar levels after thrombin, immediately accelerated the rate of return of calcium to the base line severalfold. In the present study, we used both intact and saponized platelets to determine whether this is due to stimulation of calciummore » sequestration. Using fura-2 and intact platelets, we found 1) that PMA stimulated the restoration of free Ca2+ levels after ADP as well as after thrombin, and 2) that H-7, an inhibitor of protein kinase C (Ca2+/phospholipid-dependent enzyme), slowed the return of Ca2+ to baseline levels. Using saponized platelets, we also found 3) that pretreatment of platelets with PMA before saponin treatment increased the ATP-dependent /sup 45/Ca2+ uptake 2-fold, with a half-maximal effect at 5 nm; 4) that most of the Ca2+ released by ionomycin or by myoinositol 1,4,5-trisphosphate; and 5) that a GTP-binding protein inhibitor, guanosine 5'-O-(2-thiodiphosphate), decreased basal or PMA-stimulated /sup 45/Ca2+ uptake in saponin-treated platelets. Our data suggest that activation of protein kinase C stimulates the sequestration of Ca2+ independently of cAMP or myoinositol 1,4,5-trisphosphate.« less
Measures of outcome for stimulant trials: ACTTION recommendations and research agenda.
Kiluk, Brian D; Carroll, Kathleen M; Duhig, Amy; Falk, Daniel E; Kampman, Kyle; Lai, Shengan; Litten, Raye Z; McCann, David J; Montoya, Ivan D; Preston, Kenzie L; Skolnick, Phil; Weisner, Constance; Woody, George; Chandler, Redonna; Detke, Michael J; Dunn, Kelly; Dworkin, Robert H; Fertig, Joanne; Gewandter, Jennifer; Moeller, F Gerard; Ramey, Tatiana; Ryan, Megan; Silverman, Kenneth; Strain, Eric C
2016-01-01
The development and approval of an efficacious pharmacotherapy for stimulant use disorders has been limited by the lack of a meaningful indicator of treatment success, other than sustained abstinence. In March, 2015, a meeting sponsored by Analgesic, Anesthetic, and Addiction Clinical Trial Translations, Innovations, Opportunities, and Networks (ACTTION) was convened to discuss the current state of the evidence regarding meaningful outcome measures in clinical trials for stimulant use disorders. Attendees included members of academia, funding and regulatory agencies, pharmaceutical companies, and healthcare organizations. The goal was to establish a research agenda for the development of a meaningful outcome measure that may be used as an endpoint in clinical trials for stimulant use disorders. Based on guidelines for the selection of clinical trial endpoints, the lessons learned from prior addiction clinical trials, and the process that led to identification of a meaningful indicator of treatment success for alcohol use disorders, several recommendations for future research were generated. These include a focus on the validation of patient reported outcome measures of functioning, the exploration of patterns of stimulant abstinence that may be associated with physical and/or psychosocial benefits, the role of urine testing for validating self-reported measures of stimulant abstinence, and the operational definitions for reduction-based measures in terms of frequency rather than quantity of stimulant use. These recommendations may be useful for secondary analyses of clinical trial data, and in the design of future clinical trials that may help establish a meaningful indicator of treatment success. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Breen, P P; O'Keeffe, D T; Conway, R; Lyons, G M
2006-03-01
We describe the design of an intelligent drop foot stimulator unit for use in conjunction with a commercial neuromuscular electrical nerve stimulation (NMES) unit, the NT2000. The developed micro-controller unit interfaces to a personal computer (PC) and a graphical user interface (GUI) allows the clinician to graphically specify the shape of the stimulation intensity envelope required for a subject undergoing drop foot correction. The developed unit is based on the ADuC812S micro-controller evaluation board from Analog Devices and uses two force sensitive resistor (FSR) based foot-switches to control application of stimulus. The unit has the ability to display to the clinician how the stimulus intensity envelope is being delivered during walking using a data capture capability. The developed system has a built-in algorithm to dynamically adjust the delivery of stimulus to reflect changes both within the gait cycle and from cycle to cycle. Thus, adaptive control of stimulus intensity is achieved.
Truong, Dennis Q; Hüber, Mathias; Xie, Xihe; Datta, Abhishek; Rahman, Asif; Parra, Lucas C; Dmochowski, Jacek P; Bikson, Marom
2014-01-01
Computational models of brain current flow during transcranial electrical stimulation (tES), including transcranial direct current stimulation (tDCS) and transcranial alternating current stimulation (tACS), are increasingly used to understand and optimize clinical trials. We propose that broad dissemination requires a simple graphical user interface (GUI) software that allows users to explore and design montages in real-time, based on their own clinical/experimental experience and objectives. We introduce two complimentary open-source platforms for this purpose: BONSAI and SPHERES. BONSAI is a web (cloud) based application (available at neuralengr.com/bonsai) that can be accessed through any flash-supported browser interface. SPHERES (available at neuralengr.com/spheres) is a stand-alone GUI application that allow consideration of arbitrary montages on a concentric sphere model by leveraging an analytical solution. These open-source tES modeling platforms are designed go be upgraded and enhanced. Trade-offs between open-access approaches that balance ease of access, speed, and flexibility are discussed. Copyright © 2014 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Radtke, J.; Sponner, J.; Jakobi, C.; Schneider, J.; Sommer, M.; Teichmann, T.; Ullrich, W.; Henniger, J.; Kormoll, T.
2018-01-01
Single photon detection applied to optically stimulated luminescence (OSL) dosimetry is a promising approach due to the low level of luminescence light and the known statistical behavior of single photon events. Time resolved detection allows to apply a variety of different and independent data analysis methods. Furthermore, using amplitude modulated stimulation impresses time- and frequency information into the OSL light and therefore allows for additional means of analysis. Considering the impressed frequency information, data analysis by using Fourier transform algorithms or other digital filters can be used for separating the OSL signal from unwanted light or events generated by other phenomena. This potentially lowers the detection limits of low dose measurements and might improve the reproducibility and stability of obtained data. In this work, an OSL system based on a single photon detector, a fast and accurate stimulation unit and an FPGA is presented. Different analysis algorithms which are applied to the single photon data are discussed.
Technical Rebuilding of Movement Function Using Functional Electrical Stimulation
NASA Astrophysics Data System (ADS)
Gföhler, Margit
To rebuild lost movement functions, neuroprostheses based on functional electrical stimulation (FES) artificially activate skeletal muscles in corresponding sequences, using both residual body functions and artificial signals for control. Besides the functional gain, FES training also brings physiological and psychological benefits for spinal cord-injured subjects. In this chapter, current stimulation technology and the main components of FES-based neuroprostheses including enhanced control systems are presented. Technology and application of FES cycling and rowing, both approaches that enable spinal cord-injured subjects to participate in mainstream activities and improve their health and fitness by exercising like able-bodied subjects, are discussed in detail, and an overview of neuroprostheses that aim at restoring movement functions for daily life as walking or grasping is given.
Brain Stimulation and the Role of the Right Hemisphere in Aphasia Recovery.
Turkeltaub, Peter E
2015-11-01
Aphasia is a common consequence of left hemisphere stroke and causes a disabling loss of language and communication ability. Current treatments for aphasia are inadequate, leaving a majority of aphasia sufferers with ongoing communication difficulties for the rest of their lives. In the past decade, two forms of noninvasive brain stimulation, repetitive transcranial magnetic stimulation and transcranial direct current stimulation, have emerged as promising new treatments for aphasia. The most common brain stimulation protocols attempt to inhibit the intact right hemisphere based on the hypothesis that maladaptive activity in the right hemisphere limits language recovery in the left. There is now sufficient evidence to demonstrate that this approach, at least for repetitive transcranial magnetic stimulation, improves specific language abilities in aphasia. However, the biological mechanisms that produce these behavioral improvements remain poorly understood. Taken in the context of the larger neurobiological literature on aphasia recovery, the role of the right hemisphere in aphasia recovery remains unclear. Additional research is needed to understand biological mechanisms of recovery, in order to optimize brain stimulation treatments for aphasia. This article summarizes the current evidence on noninvasive brain stimulation methods for aphasia and the neuroscientific considerations surrounding treatments using right hemisphere inhibition. Suggestions are provided for further investigation and for clinicians whose patients ask about brain stimulation treatments for aphasia.
Lee, Minji; Kim, Yun-Hee; Im, Chang-Hwan; Kim, Jung-Hoon; Park, Chang-hyun; Chang, Won Hyuk; Lee, Ahee
2015-01-01
Transcranial direct current stimulation (tDCS) non-invasively modulates brain function by inducing neuronal excitability. The conventional hot spot for inducing the highest current density in the hand motor area may not be the optimal site for effective stimulation. In this study, we investigated the influence of the center position of the anodal electrode on changes in motor cortical excitability. We considered three tDCS conditions in 16 healthy subjects: (i) real stimulation with the anodal electrode located at the conventional hand motor hot spot determined by motor evoked potentials (MEPs); (ii) real stimulation with the anodal electrode located at the point with the highest current density in the hand motor area as determined by electric current simulation; and (iii) sham stimulation. Motor cortical excitability as measured by MEP amplitude increased after both real stimulation conditions, but not after sham stimulation. Stimulation using the simulation-derived anodal electrode position, which was found to be posterior to the MEP hot spot for all subjects, induced higher motor cortical excitability. Individual positioning of the anodal electrode, based on the consideration of anatomical differences between subjects, appears to be important for maximizing the effects of tDCS. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Optoacoustic effect is responsible for laser-induced cochlear responses
NASA Astrophysics Data System (ADS)
Kallweit, N.; Baumhoff, P.; Krueger, A.; Tinne, N.; Kral, A.; Ripken, T.; Maier, H.
2016-06-01
Optical stimulation of the cochlea with laser light has been suggested as an alternative to conventional treatment of sensorineural hearing loss with cochlear implants. The underlying mechanisms are controversially discussed: The stimulation can either be based on a direct excitation of neurons, or it is a result of an optoacoustic pressure wave acting on the basilar membrane. Animal studies comparing the intra-cochlear optical stimulation of hearing and deafened guinea pigs have indicated that the stimulation requires intact hair cells. Therefore, optoacoustic stimulation seems to be the underlying mechanism. The present study investigates optoacoustic characteristics using pulsed laser stimulation for in vivo experiments on hearing guinea pigs and pressure measurements in water. As a result, in vivo as well as pressure measurements showed corresponding signal shapes. The amplitude of the signal for both measurements depended on the absorption coefficient and on the maximum of the first time-derivative of laser pulse power (velocity of heat deposition). In conclusion, the pressure measurements directly demonstrated that laser light generates acoustic waves, with amplitudes suitable for stimulating the (partially) intact cochlea. These findings corroborate optoacoustic as the basic mechanism of optical intra-cochlear stimulation.
Reflex effects on components of synchronized renal sympathetic nerve activity.
DiBona, G F; Jones, S Y
1998-09-01
The effects of peripheral thermal receptor stimulation (tail in hot water, n = 8, anesthetized) and cardiac baroreceptor stimulation (volume loading, n = 8, conscious) on components of synchronized renal sympathetic nerve activity (RSNA) were examined in rats. The peak height and peak frequency of synchronized RSNA were determined. The renal sympathoexcitatory response to peripheral thermal receptor stimulation was associated with an increase in the peak height. The renal sympathoinhibitory response to cardiac baroreceptor stimulation was associated with a decrease in the peak height. Although heart rate was significantly increased with peripheral thermal receptor stimulation and significantly decreased with cardiac baroreceptor stimulation, peak frequency was unchanged. As peak height reflects the number of active fibers, reflex increases and decreases in synchronized RSNA are mediated by parallel increases and decreases in the number of active renal nerve fibers rather than changes in the centrally based rhythm or peak frequency. The increase in the number of active renal nerve fibers produced by peripheral thermal receptor stimulation reflects the engagement of a unique group of silent renal sympathetic nerve fibers with a characteristic response pattern to stimulation of arterial baroreceptors, peripheral and central chemoreceptors, and peripheral thermal receptors.
Influence of peripheral magnetic stimulation of soleus muscle on H and M waves.
Matsuda, Tadamitsu; Kurayama, Taichi; Tagami, Miki; Fujino, Yuji; Manji, Atsushi; Kusumoto, Yasuaki; Amimoto, Kazu
2018-05-01
[Purpose] This study evaluated the effects of repetitive peripheral magnetic stimulation of the soleus muscle on spinal cord and peripheral motor nerve excitability. [Subjects and Methods] Twelve healthy adults (mean age 22 years) who provided written informed consent were administered repetitive peripheral magnetic stimulation for 10 min. Pre-and post-stimulation latencies and amplitudes of H- and M-waves of the soleus muscle were measured using electromyography and compared using paired t-tests. [Results] Pre- and post-stimulation latencies (28.3 ± 3.3 vs. 29.1 ± 1.3 ms, respectively) and amplitudes (35.8 ± 1.3 vs. 35.8 ± 1.1 mV, respectively) of H-waves were similar. Pre-stimulation latencies of M-waves were significantly higher than post-stimulation latencies (6.1 ± 2.2 vs. 5.0 ± 0.9 ms, respectively), although pre- and post-stimulation amplitudes were similar (12.2 ± 1.4 vs. 12.2 ± 1.3 mV, respectively). Motor neuron excitability, based on the excitability of motor nerves and peripheral nerve action, was increased by M-waves following magnetic stimulation. [Conclusion] The lack of effect of magnetic stimulation on the amplitude and latency of the H-reflex suggests that magnetic stimulation did not activate sensory nerve synapses of α motor neurons in the spinal cord. However, because motor nerves were stimulated together with sensory nerves, the increased H-wave amplitude may have reflected changes in peripheral rather than in α motor nerves.
Patel, Rajesh; Tsan, Alison; Sumiyoshi, Teiko; Fu, Ling; Desai, Rupal; Schoenbrunner, Nancy; Myers, Thomas W.; Bauer, Keith; Smith, Edward; Raja, Rajiv
2014-01-01
Molecular profiling of tumor tissue to detect alterations, such as oncogenic mutations, plays a vital role in determining treatment options in oncology. Hence, there is an increasing need for a robust and high-throughput technology to detect oncogenic hotspot mutations. Although commercial assays are available to detect genetic alterations in single genes, only a limited amount of tissue is often available from patients, requiring multiplexing to allow for simultaneous detection of mutations in many genes using low DNA input. Even though next-generation sequencing (NGS) platforms provide powerful tools for this purpose, they face challenges such as high cost, large DNA input requirement, complex data analysis, and long turnaround times, limiting their use in clinical settings. We report the development of the next generation mutation multi-analyte panel (MUT-MAP), a high-throughput microfluidic, panel for detecting 120 somatic mutations across eleven genes of therapeutic interest (AKT1, BRAF, EGFR, FGFR3, FLT3, HRAS, KIT, KRAS, MET, NRAS, and PIK3CA) using allele-specific PCR (AS-PCR) and Taqman technology. This mutation panel requires as little as 2 ng of high quality DNA from fresh frozen or 100 ng of DNA from formalin-fixed paraffin-embedded (FFPE) tissues. Mutation calls, including an automated data analysis process, have been implemented to run 88 samples per day. Validation of this platform using plasmids showed robust signal and low cross-reactivity in all of the newly added assays and mutation calls in cell line samples were found to be consistent with the Catalogue of Somatic Mutations in Cancer (COSMIC) database allowing for direct comparison of our platform to Sanger sequencing. High correlation with NGS when compared to the SuraSeq500 panel run on the Ion Torrent platform in a FFPE dilution experiment showed assay sensitivity down to 0.45%. This multiplexed mutation panel is a valuable tool for high-throughput biomarker discovery in personalized medicine and cancer drug development. PMID:24658394
A biomimetic bioelectronic tongue: A switch for On- and Off- response of acid sensations.
Zhang, Wei; Chen, Peihua; Zhou, Lianqun; Qin, Zhen; Gao, Keqiang; Yao, Jia; Li, Chuanyu; Wang, Ping
2017-06-15
The perception of sour taste in mammals is important for its basic modality properties and avoiding toxic substances. We explore a biomimetic bioelectronic tongue, which integrate MEA (microelectrode array) and taste receptor cell for acid detection as a switch. However, the acid-sensing mechanism and coding of the taste receptor cells in the periphery is not well understood, with long-standing debate. Therefore, we firstly construct a Hodgkin-Huxley type mathematical model of whole-cell acid-sensing taste receptor cells based on the electrophysiologic patch clamp recordings with different acid sensitive receptor expressing and different acidic stimulations. ASICs and PKDL channels are two most promising candidates for acidic sensation. ASICs channels contribute to the On response, and PKDL channels coding the Offset stimulations respectively, which function as a pair for switch. Therefore, with the advantage of effective and noninvasive detection for MEA, a sour taste biosensor based on MEA and taste receptor cells was designed and established to detect sour response from the elementary acid sensitive taste receptor cells during and after stimulus. From simulation and extracelluar potential recordings, we found the biomimetic bioelectronic tongue was acid-sensitive, as acid stimulation pH decrease, the firing frequency significantly increase. Furthermore, this reliable and effective MEA based bioelectronic tongue functioned as a switch for stimulation On and Off. This study provided a powerful platform to recognize sour stimulation and help elucidate the sour taste sensation and coding mechanism. Copyright © 2016 Elsevier B.V. All rights reserved.
López-Hill, Ximena; Prieto, José Pedro; Meikle, María Noel; Urbanavicius, Jessika; Abin-Carriquiry, Juan Andrés; Prunell, Giselle; Umpiérrez, Eleuterio; Scorza, María Cecilia
2011-08-01
Coca-paste (CP) is a drug of abuse that so far has not been extensively characterized. CP is an intermediate product of the cocaine alkaloid extraction process from coca leaves, hence it has a high content of cocaine base mixed with other chemical substances (impurities) and it is probably adulterated when it reaches the consumers. Despite its high prevalence and distribution through South America, little is known about its effects on the central nervous system. In the present study, a chemical analysis of CP samples from different police seizures was performed to determine the cocaine base content and the presence and content of impurities and adulterants. Some CP representative samples were selected to study the effects on the locomotor activity induced after acute systemic administration in rats as a measure of its stimulant action. The behavioral response was compared to equivalent doses of cocaine. As expected, cocaine was the main component in most of the CP samples assayed. Caffeine was the only active adulterant detected. Interestingly, several CP samples elicited a higher stimulant effect compared to that observed after cocaine when administered at equivalent doses of cocaine base. Combined treatment of cocaine and caffeine, as surrogate of different CP samples mimicked their stimulant effect. We demonstrated that cocaine and caffeine are the main components responsible for the CP-induced stimulant action while the contribution of the impurities was imperceptible. Copyright © 2011 Elsevier B.V. All rights reserved.
Long-term detection of Parkinsonian tremor activity from subthalamic nucleus local field potentials.
Houston, Brady; Blumenfeld, Zack; Quinn, Emma; Bronte-Stewart, Helen; Chizeck, Howard
2015-01-01
Current deep brain stimulation paradigms deliver continuous stimulation to deep brain structures to ameliorate the symptoms of Parkinson's disease. This continuous stimulation has undesirable side effects and decreases the lifespan of the unit's battery, necessitating earlier replacement. A closed-loop deep brain stimulator that uses brain signals to determine when to deliver stimulation based on the occurrence of symptoms could potentially address these drawbacks of current technology. Attempts to detect Parkinsonian tremor using brain signals recorded during the implantation procedure have been successful. However, the ability of these methods to accurately detect tremor over extended periods of time is unknown. Here we use local field potentials recorded during a deep brain stimulation clinical follow-up visit 1 month after initial programming to build a tremor detection algorithm and use this algorithm to detect tremor in subsequent visits up to 8 months later. Using this method, we detected the occurrence of tremor with accuracies between 68-93%. These results demonstrate the potential of tremor detection methods for efficacious closed-loop deep brain stimulation over extended periods of time.
Improved transcranial magnetic stimulation coil design with realistic head modeling
NASA Astrophysics Data System (ADS)
Crowther, Lawrence; Hadimani, Ravi; Jiles, David
2013-03-01
We are investigating Transcranial magnetic stimulation (TMS) as a noninvasive technique based on electromagnetic induction which causes stimulation of the neurons in the brain. TMS can be used as a pain-free alternative to conventional electroconvulsive therapy (ECT) which is still widely implemented for treatment of major depression. Development of improved TMS coils capable of stimulating subcortical regions could also allow TMS to replace invasive deep brain stimulation (DBS) which requires surgical implantation of electrodes in the brain. Our new designs allow new applications of the technique to be established for a variety of diagnostic and therapeutic applications of psychiatric disorders and neurological diseases. Calculation of the fields generated inside the head is vital for the use of this method for treatment. In prior work we have implemented a realistic head model, incorporating inhomogeneous tissue structures and electrical conductivities, allowing the site of neuronal activation to be accurately calculated. We will show how we utilize this model in the development of novel TMS coil designs to improve the depth of penetration and localization of stimulation produced by stimulator coils.
Lim, Sin How; Ostrow, David; Stall, Ron; Chmiel, Joan; Herrick, Amy; Shoptaw, Steve; Kao, Uyen; Carrico, Adam; Plankey, Michael
2012-01-01
Stimulant drug use is associated with numerous health problems among men who have sex with men (MSM). This paper describes how stimulant drug use changes over a four and one-half year period from 2003 until 2008. Participants were 2,389 men (17,222 person-visits) from The Multicenter AIDS Cohort Study (MACS)-an ongoing, prospective study of HIV infection among MSM. Group-based trajectory analyses of data from these men over the study period yielded a four groups solution: consistent users (9.8%), men whose use increased (5.4%), men whose use declined (6.9%), and abstinent or rarely-using men (77.9%). There were significant differences between groups in terms of demographic, behavioral risk and HIV serostatus. Men who increased or decreased stimulant drug use over time reported congruent changes in sexual risk taking. The fact that sexual risk levels parallel stimulant drug use over time suggests that finding ways to lower rates of stimulant drug use among MSM could be a tool in HIV prevention.
Jeong, Da Un; Lee, Jihyeon; Chang, Won Seok; Chang, Jin Woo
2017-03-07
The possibility of using deep brain stimulation (DBS) for memory enhancement has recently been reported, but the precise underlying mechanisms of its effects remain unknown. Our previous study suggested that spatial memory improvement by medial septum (MS)-DBS may be associated with cholinergic regulation and neurogenesis. However, the affected stage of memory could not be distinguished because the stimulation was delivered during the execution of all memory processes. Therefore, this study was performed to determine the stage of memory affected by MS-DBS. Rats were administered 192 IgG-saporin to lesion cholinergic neurons. Stimulation was delivered at different times in different groups of rats: 5 days before the Morris water maze test (pre-stimulation), 5 days during the training phase of the Morris water maze test (training-stimulation), and 2 h before the Morris water maze probe test (probe-stimulation). A fourth group of rats was lesioned but received no stimulation. These four groups were compared with a normal (control) group. The most effective memory restoration occurred in the pre-stimulation group. Moreover, the pre-stimulation group exhibited better recall of the platform position than the other stimulation groups. An increase in the level of brain derived neurotrophic factor (BDNF) was observed in the pre-stimulation group; this increase was maintained for 1 week. However, acetylcholinesterase activity in the pre-stimulation group was not significantly different from the lesion group. Memory impairment due to cholinergic denervation can be improved by DBS. The improvement is significantly correlated with the up-regulation of BDNF expression and neurogenesis. Based on the results of this study, the use of MS-DBS during the early stage of disease may restore spatial memory impairment.
Jung, In Duk; Shin, Sung Jae; Lee, Min-Goo; Kang, Tae Heung; Han, Hee Dong; Lee, Seung Jun; Kim, Woo Sik; Kim, Hong Min; Park, Won Sun; Kim, Han Wool; Yun, Cheol-Heui; Lee, Eun Kyung; Wu, T.-C.
2014-01-01
Despite the potential for stimulation of robust antitumor immunity by dendritic cells (DCs), clinical applications of DC-based immunotherapy are limited by the low potency in generating tumor Ag-specific T cell responses. Therefore, optimal conditions for generating potent immunostimulatory DCs that overcome tolerance and suppression are key factors in DC-based tumor immunotherapy. In this study, we demonstrate that use of the Mycobacterium tuberculosis heat shock protein X (HspX) as an immunoadjuvant in DC-based tumor immunotherapy has significant potential in therapeutics. In particular, the treatment aids the induction of tumor-reactive T cell responses, especially tumor-specific CTLs. The HspX protein induces DC maturation and proinflammatory cytokine production (TNF-α, IL-1β, IL-6, and IFN-β) through TLR4 binding partially mediated by both the MyD88 and the TRIF signaling pathways. We employed two models of tumor progression and metastasis to evaluate HspX-stimulated DCs in vivo. The administration of HspX-stimulated DCs increased the activation of naive T cells, effectively polarizing the CD4+ and CD8+ T cells to secrete IFN-γ, as well as enhanced the cytotoxicity of splenocytes against HPV-16 E7 (E7)–expressing TC-1 murine tumor cells in therapeutic experimental animals. Moreover, the metastatic capacity of B16-BL6 melanoma cancer cells toward the lungs was remarkably attenuated in mice that received HspX-stimulated DCs. In conclusion, the high therapeutic response rates with tumor-targeted Th1-type T cell immunity as a result of HspX-stimulated DCs in two models suggest that HspX harnesses the exquisite immunological power and specificity of DCs for the treatment of tumors. PMID:24990079
Luján, J L; Crago, P E
2004-11-01
Neuroprosthestic systems can be used to restore hand grasp and wrist control in individuals with C5/C6 spinal cord injury. A computer-based system was developed for the implementation, tuning and clinical assessment of neuroprosthetic controllers, using off-the-shelf hardware and software. The computer system turned a Pentium III PC running Windows NT into a non-dedicated, real-time system for the control of neuroprostheses. Software execution (written using the high-level programming languages LabVIEW and MATLAB) was divided into two phases: training and real-time control. During the training phase, the computer system collected input/output data by stimulating the muscles and measuring the muscle outputs in real-time, analysed the recorded data, generated a set of training data and trained an artificial neural network (ANN)-based controller. During real-time control, the computer system stimulated the muscles using stimulus pulsewidths predicted by the ANN controller in response to a sampled input from an external command source, to provide independent control of hand grasp and wrist posture. System timing was stable, reliable and capable of providing muscle stimulation at frequencies up to 24Hz. To demonstrate the application of the test-bed, an ANN-based controller was implemented with three inputs and two independent channels of stimulation. The ANN controller's ability to control hand grasp and wrist angle independently was assessed by quantitative comparison of the outputs of the stimulated muscles with a set of desired grasp or wrist postures determined by the command signal. Controller performance results were mixed, but the platform provided the tools to implement and assess future controller designs.
36. One of the posters used in the labor stimulation ...
36. One of the posters used in the labor stimulation campaign by Turner Construction Company during its 1918 construction projects for the U.S. Navy and U.S. Army. - U.S. Navy Fleet Supply Base, Storehouse No. 1, 830 Third Avenue, Brooklyn, Kings County, NY
Volumetric abnormalities of the brain in a rat model of recurrent headache.
Jia, Zhihua; Tang, Wenjing; Zhao, Dengfa; Hu, Guanqun; Li, Ruisheng; Yu, Shengyuan
2018-01-01
Voxel-based morphometry is used to detect structural brain changes in patients with migraine. However, the relevance of migraine and structural changes is not clear. This study investigated structural brain abnormalities based on voxel-based morphometry using a rat model of recurrent headache. The rat model was established by infusing an inflammatory soup through supradural catheters in conscious male rats. Rats were subgrouped according to the frequency and duration of the inflammatory soup infusion. Tactile sensory testing was conducted prior to infusion of the inflammatory soup or saline. The periorbital tactile thresholds in the high-frequency inflammatory soup stimulation group declined persistently from day 5. Increased white matter volume was observed in the rats three weeks after inflammatory soup stimulation, brainstem in the in the low-frequency inflammatory soup-infusion group and cortex in the high-frequency inflammatory soup-infusion group. After six weeks' stimulation, rats showed gray matter volume changes. The brain structural abnormalities recovered after the stimulation was stopped in the low-frequency inflammatory soup-infused rats and persisted even after the high-frequency inflammatory soup stimulus stopped. The changes of voxel-based morphometry in migraineurs may be the result of recurrent headache. Cognition, memory, and learning may play an important role in the chronification of migraines. Reducing migraine attacks has the promise of preventing chronicity of migraine.
Chen, Danfeng; Yan, Tiebin; Li, Guandong; Li, Fangming; Liang, Qitang
2014-10-14
To explore the possible mechanisms for improving lower extremity motor function in patients with early stroke through combining magnetic resonance diffusion tensor imaging (DTI) technology and functional electrical stimulation (FES) based on human walking patterns. From August 2012 to September 2013, a total of 48 eligible patients were stratified according to age, gender, disease course, Brunnstrom staging and types of stroke. And the Minimize software was used to divided them randomly into four-channel FES group (n = 18), dual-channel FES group (n = 15) and comfort stimulation group (n = 15). For all three groups, general medication and standard rehabilitation were provided. Based on normal walking pattern design of FES treatment, four-channel FES groups received the stimulations of quadriceps, hamstring, anterior tibialis and medial gastrocnemius. For the dual-channel FES group, the stimulations of tibialis anterior, peroneus longus and peroneus brevis muscles were applied. In comfort electrical stimulation group, the electrode positions were identical to the stimulation group, but there was no current output during stimulation. Before and after 3-week treatment, three groups received weekly rehabilitation evaluations of Fugl-Meyer assessment (FMA), posture assessment of stroke scale (PASS), Brunel balance assessment (BBA), Berg balance scale (BBS) and modified Barthel index (MBI). Before and after treatment, DTI examination was performed for some patients. Among three groups, general patient profiles and pre-treatment evaluations showed no significant difference. For intra-group comparisons versus pre-treatment, at week 1, 2 and 3, the scores of PASS, BBA, BBS, FMA and MBI had statistically significant differences (P < 0.05); At week 3 post-treatment, when four-channel and double-channel FES groups were compared versus pre-treatment, the scores of ipsilateral FA had statistically significant differences (P < 0.05). At week 1 post-treatment, MBI had statistically significant difference among 3 groups (P = 0.037). As compared with placebo, four-channel group had statistically significant difference [(52 ± 12) vs (38 ± 18), P < 0.05]; At week 2 post-treatment, the scores of PASS and MBI were (29 ± 3, 73 ± 13) in four-channel FES group versus (24 ± 8, 60 ± 17) in dual-channel FES group. And the scores of PASS, BBA, BBS, FMA and MBI were (9 ± 3, 8.3 ± 2.4, 37 ± 7, 22 ± 5, 73 ± 13) in four-channel FES group versus (21 ± 7, 6.2 ± 3.1, 24 ± 16, 15 ± 8, 47 ± 20) in comfort electrical stimulation group. When dual-channel FES and comfort stimulation groups were compared, MBI had significant statistical difference [(60 ± 17) vs (47 ± 20), P < 0.05]. At week 3 post-treatment, four-channel and dual-channel FES groups were compared, there was also statistical significance in FMA [(25 ± 5) vs (20 ± 7), P = 0.055]. The scores of PASS, BBS, FMA and MBI were (31 ± 3, 43 ± 8, 25 ± 5, 81 ± 13) in four-channel FES group versus (25 ± 8, 29 ± 17, 17 ± 9, 54 ± 25) in comfort stimulation group respectively. When dual-channel FES and comfort stimulation groups were compared, the scores of MBI were (71 ± 15) and (54 ± 25) respectively. And the difference was statistically significant (P < 0.05). At week 3 post-treatment, the scores of FA significantly increased [four-channel FES group (0.321 ± 0.172) vs comfort stimulation group (0.217 ± 0.135) (P = 0.020)]. When dual-channel FES group (0.333 ± 0.164) and comfort stimulation group (0.217 ± 0.135) (P = 0.049) were compared, the differences were statistically significant. DTI showed that four-channel FES group increased significantly, but contralateral fiber bundle was not obvious. And the improvements of dual-channel FES and comfort stimulation groups were insignificant. Compared with traditional dual-channel FES, functional electrical stimulation based on human walking patterns is more efficacious. And it helps to restore brain structure and function and promote motor function recovery in patients with early stroke.
Sleddens, Ester F C; Gubbels, Jessica S; Kremers, Stef P J; van der Plas, Eline; Thijs, Carel
2017-07-06
It has been generally assumed that activity-related parenting practices influence children's activity behavior and weight status. However, vice versa parents may also change their parenting behaviors in response to their perceptions of their child's activity behavior and weight status. This study examined the bidirectional relationships between activity-related parenting practices, and physical activity, sedentary screen-based behavior, and body mass index (BMI) between children's age of 5 and 7 years. Three scales of the Activity-related Parenting Questionnaire (i.e. 'restriction of sedentary behavior', 'stimulation of physical activity', and 'monitoring of physical activity') were completed by 1694 parents of the Dutch KOALA Birth Cohort Study at the child's age of around 5 and again around age 7. Physical activity, sedentary screen-based behavior and BMI were measured at both ages as well. Linear regression models were used to estimate the bidirectional associations between each parenting practice and the child's physical activity levels, sedentary screen-based behavior and BMI z-scores. Several parenting practices at age 5 predicted child physical activity, sedentary screen-based behavior, and BMI z-scores at age 7. Restriction of sedentary behavior positively predicted child BMI and sedentary screen-based behavior, whereas this practice negatively predicted child physical activity. In addition, stimulation of physical activity at age 5 was significantly associated with higher levels of child physical activity at age 7. The following child factors at age 5 predicted parenting practices at age 7: Child physical activity positively predicted parental stimulation of physical activity and monitoring activities. Sedentary screen-based behavior was associated with lower parental stimulation to be active. Findings generally revealed that parents and children mutually influence each other's behavior. A reinforcing feedback loop was present between parental stimulation of physical activity and child physical activity. Bidirectional parent-child interaction should be considered in future research in order to properly inform parenting-related intervention programs aimed at preventing or treating childhood overweight or obesity. System dynamic methods to explore the existence of reinforcing or balancing loops are needed in this regard.
Observations of HF backscatter decay rates from HAARP generated FAI
NASA Astrophysics Data System (ADS)
Bristow, William; Hysell, David
2016-07-01
Suitable experiments at the High-frequency Active Auroral Research Program (HAARP) facilities in Gakona, Alaska, create a region of ionospheric Field-Aligned Irregularities (FAI) that produces strong radar backscatter observed by the SuperDARN radar on Kodiak Island, Alaska. Creation of FAI in HF ionospheric modification experiments has been studied by a number of authors who have developed a rich theoretical background. The decay of the irregularities, however, has not been so widely studied yet it has the potential for providing estimates of the parameters of natural irregularity diffusion, which are difficult measure by other means. Hysell, et al. [1996] demonstrated using the decay of radar scatter above the Sura heating facility to estimate irregularity diffusion. A large database of radar backscatter from HAARP generated FAI has been collected over the years. Experiments often cycled the heater power on and off in a way that allowed estimates of the FAI decay rate. The database has been examined to extract decay time estimates and diffusion rates over a range of ionospheric conditions. This presentation will summarize the database and the estimated diffusion rates, and will discuss the potential for targeted experiments for aeronomy measurements. Hysell, D. L., M. C. Kelley, Y. M. Yampolski, V. S. Beley, A. V. Koloskov, P. V. Ponomarenko, and O. F. Tyrnov, HF radar observations of decaying artificial field aligned irregularities, J. Geophys. Res. , 101, 26,981, 1996.
Observations of HF backscatter decay rates from HAARP generated FAI
NASA Astrophysics Data System (ADS)
Bristow, W. A.; Hysell, D. L.
2016-12-01
Suitable experiments at the High-frequency Active Auroral Research Program (HAARP) facilities in Gakona, Alaska, create a region of ionospheric Field-Aligned Irregularities (FAI) that produces strong radar backscatter observed by the SuperDARN radar on Kodiak Island, Alaska. Creation of FAI in HF ionospheric modification experiments has been studied by a number of authors who have developed a rich theoretical background. The decay of the irregularities, however, has not been so widely studied yet it has the potential for providing estimates of the parameters of natural irregularity diffusion, which are difficult measure by other means. Hysell, et al. [1996] demonstrated using the decay of radar scatter above the Sura heating facility to estimate irregularity diffusion. A large database of radar backscatter from HAARP generated FAI has been collected over the years. Experiments often cycled the heater power on and off in a way that allowed estimates of the FAI decay rate. The database has been examined to extract decay time estimates and diffusion rates over a range of ionospheric conditions. This presentation will summarize the database and the estimated diffusion rates, and will discuss the potential for targeted experiments for aeronomy measurements. Hysell, D. L., M. C. Kelley, Y. M. Yampolski, V. S. Beley, A. V. Koloskov, P. V. Ponomarenko, and O. F. Tyrnov, HF radar observations of decaying artificial field aligned irregularities, J. Geophys. Res. , 101, 26,981, 1996.
Measuring anisotropic muscle stiffness properties using elastography.
Green, M A; Geng, G; Qin, E; Sinkus, R; Gandevia, S C; Bilston, L E
2013-11-01
Physiological and pathological changes to the anisotropic mechanical properties of skeletal muscle are still largely unknown, with only a few studies quantifying changes in vivo. This study used the noninvasive MR elastography (MRE) technique, in combination with diffusion tensor imaging (DTI), to measure shear modulus anisotropy in the human skeletal muscle in the lower leg. Shear modulus measurements parallel and perpendicular to the fibre direction were made in 10 healthy subjects in the medial gastrocnemius, soleus and tibialis anterior muscles. The results showed significant differences in the medial gastrocnemius (μ‖ = 0.86 ± 0.15 kPa; μ⊥ = 0.66 ± 0.19 kPa, P < 0.001), soleus (μ‖ = 0.83 ± 0.22 kPa; μ⊥ = 0.65 ± 0.13 kPa, P < 0.001) and the tibialis anterior (μ‖ = 0.78 ± 0.24 kPa; μ⊥ = 0.66 ± 0.16 kPa, P = 0.03) muscles, where the shear modulus measured in the direction parallel is greater than that measured in the direction perpendicular to the muscle fibres. No significant differences were measured across muscle groups. This study provides the first direct estimates of the anisotropic shear modulus in the triceps surae muscle group, and shows that the technique may be useful for the probing of mechanical anisotropy changes caused by disease, aging and injury. Copyright © 2013 John Wiley & Sons, Ltd.
Elzibak, Alyaa H; Noseworthy, Michael D
2014-10-01
To investigate whether postural change from erect to recumbent position affects calf muscle water diffusivity. Ten healthy adults (27.2 ± 4.9 years, 3 females) were imaged at baseline (following assumption of recumbent position), and after 34 min (session 2) and 64 min (session 3) of laying supine within a 3T MRI scanner. Diffusion tensor imaging (DTI) eigenvalues, fractional anisotropy (FA) and apparent diffusion coefficient (ADC) were evaluated in five calf muscles (anterior and posterior tibialis and triceps surae) during each of the three imaging sessions. Significant decreases were observed in all of the eigenvalues and ADC in each of the muscles with postural change. These reductions ranged from 3.2 to 6.7% and 3.4 to 7.5% for the various DTI metrics, following 34 and 64 min of supine rest, respectively (P < 0.05). No significant differences were noted in ADC or eigenvalues between the second and third imaging sessions for any muscle. FA did not change significantly with postural manipulation in any muscle compartment. Diffusion tensor imaging indices were altered with postural change. As differences were not apparent between the latter two imaging sessions, we suggest that a short supine resting period (~34 min) is sufficient for muscle diffusivity to stabilize prior to quantitative MR imaging in healthy young adults.
Grosset, Jean-François; Lapole, Thomas; Mora, Isabelle; Verhaeghe, Martine; Doutrellot, Pierre-Louis; Pérot, Chantal
2010-08-01
Clinical manual tests refer to increased ankle stiffness in children immobilized due to hip osteochondritis. The aim of the present study was to investigate musculo-articular stiffness via different techniques in immobilized children to confirm or not and quantify these observations. Ankle stiffness was quantified monthly during the long immobilization period in three diseased children and compared to healthy age-matched children. Sinusoidal perturbations were used to evaluate musculo-articular (MA) stiffness of the ankle plantar-flexors. The stiffness index (SI(MA-EMG)) was the slope of the linear relationship between angular stiffness and plantar-flexion torque normalized with electromyographic activity of the triceps surae (TS). The stiffness of the ankle plantar-flexors was also indirectly evaluated using the TS electromechanical delay (EMD). SI(MA-EMG) was greater for diseased children, and this higher stiffness was confirmed by the higher EMD values found in these immobilized children. Furthermore, both parameters indicated that ankle stiffness continues to increase through immobilization period. This study gives a quantitative evaluation of ankle stiffness changes through the immobilization period imposed to children treated for hip osteochondritis. The use of EMD measurement to indirectly evaluate these stiffness changes is also validated. This study shed for the first time some light into the patterns of muscle modifications following immobilization in children. Copyright (c) 2010 Elsevier Ltd. All rights reserved.
Dallmeijer, A J; Baker, R; Dodd, K J; Taylor, N F
2011-03-01
The purpose of this study was to determine the association between isometric muscle strength of the lower limbs and gait joint kinetics in adolescents and young adults with cerebral palsy (CP). Twenty-five participants (11 males) with bilateral spastic CP, aged 14-22 years (mean: 18.9, sd: 2.0 yr) and Gross Motor Function Classification System (GMFCS) level II (n=19) and III (n=6) were tested. Hand held dynamometry was used to measure isometric strength (expressed in Nm/kg) of the hip, knee, and ankle muscles using standardized testing positions and procedures. 3D gait analysis was performed with a VICON system to calculate joint kinetics in the hip, knee and ankle during gait. Ankle peak moments exceeded by far the levels of isometric strength of the plantar flexors, while the knee and hip peak moments were just at or below maximal isometric strength of knee and hip muscles. Isometric muscle strength showed weak to moderate correlations with peak ankle and hip extension moment and power during walking. Despite considerable muscle weakness, joint moment curves were similar to norm values. Results suggest that passive stretch of the muscle-tendon complex of the triceps surae contributes to the ankle moment during walking and that muscle strength assessment may provide additional information to gait kinetics. Copyright © 2010 Elsevier B.V. All rights reserved.
Qi, Yong; Xiong, Xiaolu; Wang, Xile; Duan, Changsong; Jia, Yinjun; Jiao, Jun; Gong, Wenping; Wen, Bohai
2013-01-01
Background Rickettsia heilongjiangensis, the agent of Far-Eastern spotted fever (FESF), is an obligate intracellular bacterium. The surface-exposed proteins (SEPs) of rickettsiae are involved in rickettsial adherence to and invasion of host cells, intracellular bacterial growth, and/or interaction with immune cells. They are also potential molecular candidates for the development of diagnostic reagents and vaccines against rickettsiosis. Methods R. heilongjiangensis SEPs were identified by biotin-streptavidin affinity purification and 2D electrophoreses coupled with ESI-MS/MS. Recombinant SEPs were probed with various sera to analyze their serological characteristics using a protein microarray and an enzyme-linked immune sorbent assay (ELISA). Results Twenty-five SEPs were identified, most of which were predicted to reside on the surface of R. heilongjiangensis cells. Bioinformatics analysis suggests that these proteins could be involved in bacterial pathogenesis. Eleven of the 25 SEPs were recognized as major seroreactive antigens by sera from R. heilongjiangensis-infected mice and FESF patients. Among the major seroreactive SEPs, microarray assays and/or ELISAs revealed that GroEL, OmpA-2, OmpB-3, PrsA, RplY, RpsB, SurA and YbgF had modest sensitivity and specificity for recognizing R. heilongjiangensis infection and/or spotted fever. Conclusions Many of the SEPs identified herein have potentially important roles in R. heilongjiangensis pathogenicity. Some of them have potential as serodiagnostic antigens or as subunit vaccine antigens against the disease. PMID:23894656
Driss, Tarak; Rouis, Majdi; Jaafar, Hamdi; Vandewalle, Henry
2015-01-01
The relationships between ankle plantar flexor musculotendinous stiffness (MTS) and performance in a countermovement vertical jump (CMJ) and maximal rate of torque development (MRTD) were studied in 27 active men. MTS was studied by means of quick releases at 20 (S 0.2), 40 (S 0.4), 60 (S 0.6), and 80% (S 0.8) of maximal voluntary torque (T MVC). CMJ was not correlated with strength indices but was positively correlated with MRTD/BM, S 0.4/BM. The slope α 2 and intercept β 2 of the torque-stiffness relationships from 40 to 80% T MVC were correlated negatively (α 2) and positively (β 2) with CMJ. The different stiffness indices were not correlated with MRTD. The prediction of CMJ was improved by the introduction of MRTD in multiple regressions between CMJ and stiffness. CMJ was also negatively correlated with indices of curvature of the torque-stiffness relationship. The subjects were subdivided in 3 groups in function of CMJ (groups H, M, and L for high, medium, and low performers, resp.). There was a downward curvature of the torque-stiffness relationship at high torques in group H or M and the torque-stiffness regression was linear in group L only. These results suggested that torque-stiffness relationships with a plateau at high torques are more frequent in the best jumpers. PMID:25710026
Gill, Jaspret
2018-01-01
Individuals may stand with a range of ankle angles. Furthermore, shoes or floor surfaces may elevate or depress their heels. Here we ask how these situations impact ankle stiffness and balance. We performed two studies (each with 10 participants) in which the triceps surae, Achilles tendon and aponeurosis were stretched either passively, by rotating the support surface, or actively by leaning forward. Participants stood freely on footplates which could rotate around the ankle joint axis. Brief, small stiffness-measuring perturbations (<0.7 deg; 140 ms) were applied at intervals of 4–5 s. In study 1, participants stood at selected angles of forward lean. In study 2, normal standing was compared with passive dorsiflexion induced by 15 deg toes-up tilt of the support surface. Smaller perturbations produced higher stiffness estimates, but for all perturbation sizes stiffness increased with active torque or passive stretch. Sway was minimally affected by stretch or lean, suggesting that this did not underlie the alterations in stiffness. In quiet stance, maximum ankle stiffness is limited by the tendon. As tendon strain increases, it becomes stiffer, causing an increase in overall ankle stiffness, which would explain the effects of leaning. However, stiffness also increased considerably with passive stretch, despite a modest torque increase. We discuss possible explanations for this increase. PMID:29558469
Brilhault, Jean; Noël, Vincent
2012-10-01
The decision to offer surgery for Stage II posterior tibial tendon deficiency (PTTD) is a difficult one since orthotic treatment has been documented to be a viable alternative to surgery at this stage. Taking this into consideration we limited our treatment to bony realignment by a lengthening calcaneus Evans osteotomy and tendon balancing. The goal of the study was to clinically evaluate PTT functional recovery with this procedure. The patient population included 17 feet in 13 patients. Inclusion was limited to early Stage II PTTD flatfeet with grossly intact but deficient PTT. Deficiency was assessed by the lack of hindfoot inversion during single heel rise test. The surgical procedure included an Evans calcaneal opening wedge osteotomy with triceps surae and peroneus brevis tendon lengthening. PTT function at follow up was evaluated by an independent examiner. Evaluation was performed at an average of 4 (range, 2 to 6.3) years. One case presented postoperative subtalar pain that required subtalar fusion. Every foot could perform a single heel rise with 13 feet having active inversion of the hindfoot during elevation. The results of this study provide evidence of PTT functional recovery without augmentation in early Stage II. It challenges our understanding of early Stage II PTTD as well as the surgical guidelines recommending PTT augmentation at this specific stage.
Tracking cells implanted into cynomolgus monkeys (Macaca fascicularis) using MRI
Ito-Fujishiro, Yasuyo; Koie, Hiroshi; Shibata, Hiroaki; Okabayashi, Sachi; Katakai, Yuko; Ohno, Chieko; Kanayama, Kiichi; Yasutomi, Yasuhiro; Ageyama, Naohide
2016-01-01
Regenerative therapy with stem cell transplantation is used to treat various diseases such as coronary syndrome and Buerger’s disease. For instance, stem-cell transplantation into the infarcted myocardium is an innovative and promising strategy for treating heart failure due to ischemic heart disease. Basic studies using small animals have shown that transplanted cells improve blood flow in the infarcted region. Magnetic resonance imaging (MRI) can noninvasively identify and track transplanted cells labeled with superparamagnetic iron oxide (SPIO). Although clinical regenerative therapies have been clinically applied to patients, the fate of implanted cells remains unknown. In addition, follow-up studies have shown that some adverse events can occur after recovery. Therefore, the present study evaluated the ability of MRI using a 3T scanner to track implanted peripheral blood mononuclear cells labeled with SPIO on days 0 and 7 after intramuscular (i.m.) and intravenous (i.v.) injection into a cynomolgus monkey. Labeled cells were visualized at the liver and triceps surae muscle on MR images using T1- and T2-weighted sequences and histologically localized by Prussian blue staining. The transplanted cells were tracked without abnormal clinical manifestations throughout this study. Hence, MRI of cynomolgus monkey transplanted SPIO-labeled cells is a safe and efficient method of tracking labeled cells that could help to determine the mechanisms involved in regenerative therapy. PMID:27062993
Differential Modulation of Excitatory and Inhibitory Neurons during Periodic Stimulation
Mahmud, Mufti; Vassanelli, Stefano
2016-01-01
Non-invasive transcranial neuronal stimulation, in addition to deep brain stimulation, is seen as a promising therapeutic and diagnostic approach for an increasing number of neurological diseases such as epilepsy, cluster headaches, depression, specific type of blindness, and other central nervous system disfunctions. Improving its effectiveness and widening its range of use may strongly rely on development of proper stimulation protocols that are tailored to specific brain circuits and that are based on a deep knowledge of different neuron types response to stimulation. To this aim, we have performed a simulation study on the behavior of excitatory and inhibitory neurons subject to sinusoidal stimulation. Due to the intrinsic difference in membrane conductance properties of excitatory and inhibitory neurons, we show that their firing is differentially modulated by the wave parameters. We analyzed the behavior of the two neuronal types for a broad range of stimulus frequency and amplitude and demonstrated that, within a small-world network prototype, parameters tuning allow for a selective enhancement or suppression of the excitation/inhibition ratio. PMID:26941602
MEMS technologies for epiretinal stimulation of the retina
NASA Astrophysics Data System (ADS)
Mokwa, W.
2004-09-01
It has been shown that electrical stimulation of retinal ganglion cells yields visual sensations. Therefore, a retina implant for blind humans suffering from retinitis pigmentosa based on this concept seems to be feasible. In Germany, there are two projects funded by the government working on different approaches namely the subretinal and the epiretinal approaches. This paper describes the epiretinal approach for such a system. The extraocular part of this system records visual images. The images are transformed by a neural net into corresponding signals for stimulation of the retinal ganglion cells. These signals are transmitted to a receiver unit of an intraocular implant, the retina stimulator. Integrated circuitry of this unit decodes the signals and transfers the data to a stimulation circuitry that selects stimulation electrodes placed onto the retina and generates current pulses to the electrodes. By this, action potentials in retinal ganglion cells are evoked, causing a visual sensation. This paper concentrates on the MEMS part of this implant.
Short-pulse amplification by strongly coupled stimulated Brillouin scattering
DOE Office of Scientific and Technical Information (OSTI.GOV)
Edwards, Matthew R., E-mail: mredward@princeton.edu; Mikhailova, Julia M.; Jia, Qing
2016-08-15
We examine the feasibility of strongly coupled stimulated Brillouin scattering as a mechanism for the plasma-based amplification of sub-picosecond pulses. In particular, we use fluid theory and particle-in-cell simulations to compare the relative advantages of Raman and Brillouin amplification over a broad range of achievable parameters.
The Mediating Effects of Generative Cognition on Imagination Stimulation
ERIC Educational Resources Information Center
Hsu, Yuling; Liang, Chaoyun; Chang, Chi-Cheng
2014-01-01
This study, based in Taiwan, aims to explore what psychological factors influence imagination stimulation of education major students, and what the relationship is between these factors and imagination. Both principal component analysis and confirmatory factor analysis were employed to determine the most appropriate structure of the developed…
Dieckmann, Peter
2012-06-01
Debriefing is important in simulation-based education but rarely studied empirically. In this article, I describe an experience-based workshop concept that was tested with approximately 80 participants during the Annual Meeting of the Society in Europe for Simulation Applied to Medicine (SESAM), June 2 to 4, 2011, in Granada, Spain. On a metalevel, the goal of the workshop was to raise the awareness of debriefing as an important part of simulation-based learning and to increase the awareness about different styles of debriefing-possibly stimulating further investigations of debriefings.
Technological Advances in Deep Brain Stimulation.
Ughratdar, Ismail; Samuel, Michael; Ashkan, Keyoumars
2015-01-01
Functional and stereotactic neurosurgery has always been regarded as a subspecialty based on and driven by technological advances. However until recently, the fundamentals of deep brain stimulation (DBS) hardware and software design had largely remained stagnant since its inception almost three decades ago. Recent improved understanding of disease processes in movement disorders as well clinician and patient demands has resulted in new avenues of development for DBS technology. This review describes new advances both related to hardware and software for neuromodulation. New electrode designs with segmented contacts now enable sophisticated shaping and sculpting of the field of stimulation, potentially allowing multi-target stimulation and avoidance of side effects. To avoid lengthy programming sessions utilising multiple lead contacts, new user-friendly software allows for computational modelling and individualised directed programming. Therapy delivery is being improved with the next generation of smaller profile, longer-lasting, re-chargeable implantable pulse generators (IPGs). These include IPGs capable of delivering constant current stimulation or personalised closed-loop adaptive stimulation. Post-implantation Magnetic Resonance Imaging (MRI) has long been an issue which has been partially overcome with 'MRI conditional devices' and has enabled verification of DBS lead location. Surgical technique is considering a shift from frame-based to frameless stereotaxy or greater role for robot assisted implantation. The challenge for these contemporary techniques however, will be in demonstrating equivalent safety and accuracy to conventional methods. We also discuss potential future direction utilising wireless technology allowing for miniaturisation of hardware.
Davidson, Clare M; de Paor, Annraoi M; Cagnan, Hayriye; Lowery, Madeleine M
2016-01-01
Parkinson's disease is a progressive, neurodegenerative disorder, characterized by hallmark motor symptoms. It is associated with pathological, oscillatory neural activity in the basal ganglia. Deep brain stimulation (DBS) is often successfully used to treat medically refractive Parkinson's disease. However, the selection of stimulation parameters is based on qualitative assessment of the patient, which can result in a lengthy tuning period and a suboptimal choice of parameters. This study explores fourth-order, control theory-based models of oscillatory activity in the basal ganglia. Describing function analysis is applied to examine possible mechanisms for the generation of oscillations in interacting nuclei and to investigate the suppression of oscillations with high-frequency stimulation. The theoretical results for the suppression of the oscillatory activity obtained using both the fourth-order model, and a previously described second-order model, are optimized to fit clinically recorded local field potential data obtained from Parkinsonian patients with implanted DBS. Close agreement between the power of oscillations recorded for a range of stimulation amplitudes is observed ( R(2)=0.69-0.99 ). The results suggest that the behavior of the system and the suppression of pathological neural oscillations with DBS is well described by the macroscopic models presented. The results also demonstrate that in this instance, a second-order model is sufficient to model the clinical data, without the need for added complexity. Describing the system behavior with computationally efficient models could aid in the identification of optimal stimulation parameters for patients in a clinical environment.
Lu, Mai; Ueno, Shoogo
2017-01-01
Stimulation of deeper brain structures by transcranial magnetic stimulation (TMS) plays a role in the study of reward and motivation mechanisms, which may be beneficial in the treatment of several neurological and psychiatric disorders. However, electric field distributions induced in the brain by deep transcranial magnetic stimulation (dTMS) are still unknown. In this paper, the double cone coil, H-coil and Halo-circular assembly (HCA) coil which have been proposed for dTMS have been numerically designed. The distributions of magnetic flux density, induced electric field in an anatomically based realistic head model by applying the dTMS coils were numerically calculated by the impedance method. Results were compared with that of standard figure-of-eight (Fo8) coil. Simulation results show that double cone, H- and HCA coils have significantly deep field penetration compared to the conventional Fo8 coil, at the expense of induced higher and wider spread electrical fields in superficial cortical regions. Double cone and HCA coils have better ability to stimulate deep brain subregions compared to that of the H-coil. In the mean time, both double cone and HCA coils increase risk for optical nerve excitation. Our results suggest although the dTMS coils offer new tool with potential for both research and clinical applications for psychiatric and neurological disorders associated with dysfunctions of deep brain regions, the selection of the most suitable coil settings for a specific clinical application should be based on a balanced evaluation between stimulation depth and focality.
A multi-pad electrode based functional electrical stimulation system for restoration of grasp
2012-01-01
Background Functional electrical stimulation (FES) applied via transcutaneous electrodes is a common rehabilitation technique for assisting grasp in patients with central nervous system lesions. To improve the stimulation effectiveness of conventional FES, we introduce multi-pad electrodes and a new stimulation paradigm. Methods The new FES system comprises an electrode composed of small pads that can be activated individually. This electrode allows the targeting of motoneurons that activate synergistic muscles and produce a functional movement. The new stimulation paradigm allows asynchronous activation of motoneurons and provides controlled spatial distribution of the electrical charge that is delivered to the motoneurons. We developed an automated technique for the determination of the preferred electrode based on a cost function that considers the required movement of the fingers and the stabilization of the wrist joint. The data used within the cost function come from a sensorized garment that is easy to implement and does not require calibration. The design of the system also includes the possibility for fine-tuning and adaptation with a manually controllable interface. Results The device was tested on three stroke patients. The results show that the multi-pad electrodes provide the desired level of selectivity and can be used for generating a functional grasp. The results also show that the procedure, when performed on a specific user, results in the preferred electrode configuration characteristics for that patient. The findings from this study are of importance for the application of transcutaneous stimulation in the clinical and home environments. PMID:23009589
Nonlinear X-Ray and Auger Spectroscopy at X-Ray Free-Electron Laser Sources
NASA Astrophysics Data System (ADS)
Rohringer, Nina
2015-05-01
X-ray free-electron lasers (XFELs) open the pathway to transfer non-linear spectroscopic techniques to the x-ray domain. A promising all x-ray pump probe technique is based on coherent stimulated electronic x-ray Raman scattering, which was recently demonstrated in atomic neon. By tuning the XFEL pulse to core-excited resonances, a few seed photons in the spectral tail of the XFEL pulse drive an avalanche of resonant inelastic x-ray scattering events, resulting in exponential amplification of the scattering signal by of 6-7 orders of magnitude. Analysis of the line profile of the emitted radiation permits to demonstrate the cross over from amplified spontaneous emission to coherent stimulated resonance scattering. In combination with statistical covariance mapping, a high-resolution spectrum of the resonant inelastic scattering process can be obtained, opening the path to coherent stimulated x-ray Raman spectroscopy. An extension of these ideas to molecules and a realistic feasibility study of stimulated electronic x-ray Raman scattering in CO will be presented. Challenges to realizing stimulated electronic x-ray Raman scattering at present-day XFEL sources will be discussed, corroborated by results of a recent experiment at the LCLS XFEL. Due to the small gain cross section in molecular targets, other nonlinear spectroscopic techniques such as nonlinear Auger spectroscopy could become a powerful alternative. Theory predictions of a novel pump probe technique based on resonant nonlinear Auger spectroscopic will be discussed and the method will be compared to stimulated x-ray Raman spectroscopy.
Michelle Welman, F H S; Smit, Albertine E; Jongen, Joost L M; Tibboel, Dick; van der Geest, Jos N; Holstege, Jan C
2018-02-26
Many fMRI studies have shown activity in the cerebellum after peripheral nociceptive stimulation. We investigated whether the areas in the cerebellum that were activated after nociceptive thumb stimulation were separate from those after nociceptive toe stimulation. In an additional experiment, we investigated the same for the anticipation of a nociceptive stimulation on the thumb or toe. For his purpose, we used fMRI after an electrical stimulation of the thumb and toe in 19 adult healthy volunteers. Following nociceptive stimulation, different areas were activated by stimulation on the thumb (lobule VI ipsilaterally and Crus II mainly contralaterally) and toe (lobules VIII-IX and IV-V bilaterally and lobule VI contralaterally), i.e., were somatotopically organized. Cerebellar areas innervated non-somatotopically by both toe and thumb stimulation were the posterior vermis and Crus I, bilaterally. In the anticipation experiment, similar results were found. However, here, the somatotopically activated areas were relatively small for thumb and negligible for toe stimulation, while the largest area was innervated non-somatotopically and consisted mainly of Crus I and lobule VI bilaterally. These findings indicate that nociceptive stimulation and anticipation of nociceptive stimulation are at least partly processed by the same areas in the cerebellum. This was confirmed by an additional conjunction analysis. Based on our findings, we hypothesize that input that is organized in a somatotopical manner reflects direct input from the spinal cord, while non-somatotopically activated parts of the cerebellum receive their information indirectly through cortical and subcortical connections, possibly involved in processing contextual emotional states, like the expectation of pain.
An electric stimulation system for electrokinetic particle manipulation in microfluidic devices.
Lopez-de la Fuente, M S; Moncada-Hernandez, H; Perez-Gonzalez, V H; Lapizco-Encinas, B H; Martinez-Chapa, S O
2013-03-01
Microfluidic devices have grown significantly in the number of applications. Microfabrication techniques have evolved considerably; however, electric stimulation systems for microdevices have not advanced at the same pace. Electric stimulation of micro-fluidic devices is an important element in particle manipulation research. A flexible stimulation instrument is desired to perform configurable, repeatable, automated, and reliable experiments by allowing users to select the stimulation parameters. The instrument presented here is a configurable and programmable stimulation system for electrokinetic-driven microfluidic devices; it consists of a processor, a memory system, and a user interface to deliver several types of waveforms and stimulation patterns. It has been designed to be a flexible, highly configurable, low power instrument capable of delivering sine, triangle, and sawtooth waveforms with one single frequency or two superimposed frequencies ranging from 0.01 Hz to 40 kHz, and an output voltage of up to 30 Vpp. A specific stimulation pattern can be delivered over a single time period or as a sequence of different signals for different time periods. This stimulation system can be applied as a research tool where manipulation of particles suspended in liquid media is involved, such as biology, medicine, environment, embryology, and genetics. This system has the potential to lead to new schemes for laboratory procedures by allowing application specific and user defined electric stimulation. The development of this device is a step towards portable and programmable instrumentation for electric stimulation on electrokinetic-based microfluidic devices, which are meant to be integrated with lab-on-a-chip devices.
An electric stimulation system for electrokinetic particle manipulation in microfluidic devices
NASA Astrophysics Data System (ADS)
Lopez-de la Fuente, M. S.; Moncada-Hernandez, H.; Perez-Gonzalez, V. H.; Lapizco-Encinas, B. H.; Martinez-Chapa, S. O.
2013-03-01
Microfluidic devices have grown significantly in the number of applications. Microfabrication techniques have evolved considerably; however, electric stimulation systems for microdevices have not advanced at the same pace. Electric stimulation of micro-fluidic devices is an important element in particle manipulation research. A flexible stimulation instrument is desired to perform configurable, repeatable, automated, and reliable experiments by allowing users to select the stimulation parameters. The instrument presented here is a configurable and programmable stimulation system for electrokinetic-driven microfluidic devices; it consists of a processor, a memory system, and a user interface to deliver several types of waveforms and stimulation patterns. It has been designed to be a flexible, highly configurable, low power instrument capable of delivering sine, triangle, and sawtooth waveforms with one single frequency or two superimposed frequencies ranging from 0.01 Hz to 40 kHz, and an output voltage of up to 30 Vpp. A specific stimulation pattern can be delivered over a single time period or as a sequence of different signals for different time periods. This stimulation system can be applied as a research tool where manipulation of particles suspended in liquid media is involved, such as biology, medicine, environment, embryology, and genetics. This system has the potential to lead to new schemes for laboratory procedures by allowing application specific and user defined electric stimulation. The development of this device is a step towards portable and programmable instrumentation for electric stimulation on electrokinetic-based microfluidic devices, which are meant to be integrated with lab-on-a-chip devices.
Chen, Lian-Yu; Strain, Eric C.; Crum, Rosa M.; Storr, Carla L.; Mojtabai, Ramin
2014-01-01
Aim Epidemiological data indicate that nonmedical use of prescription stimulants has increased over the past decade. However, little is known regarding the source of the misused stimulants and whether different sources correspond to differences in risk profiles and associated social and health problems. Method Data from the 2006 to 2011 National Survey on Drug Use and Health were used. A total of 4,945 participants who used prescription stimulants nonmedically and also reported their source of misused stimulants were categorized by the source: friend/relative, physician and illegal. Logistic regression models compared the socio-demographic, mental health and behavioral problems, and stimulant use-related problems (onset, recency, frequency, severity) according to the source of the misused stimulants. Results The most common sources of stimulants were friends/relatives, followed by physicians and illegal sources. Compared to participants reporting friends/relatives as the source, participants reporting an illegal source were more likely to be male, unemployed, have less than a high school education, a history of criminal behavior and an earlier age of use onset. Participants reporting a physician source were more likely to have mental health problems and mental health service use. Higher odds of past-month stimulant use, frequent use (≥10 days per year), drug dependence and substance service use were found in individuals reporting physician and illegal sources. Conclusions Identifying the source of misused stimulants may be useful in detecting distinct subgroups of nonmedical prescription stimulant users, which may inform development of tailored prevention and treatment programs and contribute to individual treatment planning. PMID:25454408
THE AVAILABILITY AND PORTRAYAL OF STIMULANTS OVER THE INTERNET
Schepis, Ty S.; Marlowe, Douglas B.; Forman, Robert F.
2008-01-01
Purpose To quantify the online availability and portrayal of amphetamine-class prescription stimulants with a focus on those medications commonly prescribed to and abused by adolescents. Methods The Google™ search engine was used in searches to assess the frequency of websites offering to sell controlled stimulants (retail sites) or websites that directly linked to retail sites (portal sites). Also, separate searches evaluated the portrayal of controlled prescription stimulants by the initial 20 websites returned by Google™. Retail and portal website frequency was collected for each search. For searches measuring the portrayal of stimulants, webpages were categorized as pro-abuse, anti-abuse, neutral or other, based on set criteria. Results Sites offering to sell stimulants without a prescription were found for nearly all search terms. Across all searches, the Schedule III stimulants indicated for the treatment of obesity returned more sites offering to sell stimulants without a prescription than Schedule II stimulants indicated for the treatment of ADHD. Internet site portrayal of each stimulant varied. However, sites that contained “methamphetamine” often included anti-abuse information. Discussion The apparent availability of stimulants over the Internet without a prescription indicates the potential for a significant public health problem. The extent to which teens are obtaining these drugs via the Internet remains unclear, but clinicians must be aware of the potential for abuse, concomitant prescription use issues, illicit sources, and diversion of these highly addictive medications. Education of consumers and physicians as well as further governmental interventions is needed to limit the potential scope of this problem. PMID:18407040
Herman, Lawrence; Shtayermman, Oren; Aksnes, Brittany; Anzalone, Michelle; Cormerais, Andre; Liodice, Christina
2011-01-01
Prescription stimulant use as academic performance enhancers is increasingly widespread among college students. The purpose of this study was to evaluate the prevalence of prescription stimulant use among health care students attending a university in the northeastern United States. The study investigated the specific stimulants being used and the frequency of usage. It also examined the rates of nicotine, alcohol, and drug abuse versus dependence. A web-based survey was administered to medical and health profession students regarding prescription stimulant use for nonprescribed purposes. Tobacco, alcohol, and recreational drug use were also surveyed. Approximately 10.4% (32) of students surveyed have either used a stimulant or are currently using prescription stimulants illegally. The most common reason for stimulant use was to focus and concentrate during studying (93.5%). Of the 308 students, 45.2% were female, 83.9% were Caucasian, and amphetamine-dextroamphetamine was the most commonly abused stimulant (71.4%). Results from this study are consistent with previous research of undergraduate students regarding prescription stimulant use for nonprescribed purposes, specifically for academic performance enhancement. Data from the study support that alcohol abuse and dependence among students is a pertinent concern, suggesting that substance abuse in general must be addressed. Substance abuse and awareness programs combined with stress management programs in an overall substance-abuse reduction strategy, including the use of prescription stimulant use beyond the originally intended purpose, may be beneficial. Because of the lack of research focusing on graduate health care students, further investigations should use similar populations.
Rouhollahi, Korosh; Emadi Andani, Mehran; Karbassi, Seyed Mahdi; Izadi, Iman
2017-02-01
Deep brain stimulation (DBS) is an efficient therapy to control movement disorders of Parkinson's tremor. Stimulation of one area of basal ganglia (BG) by DBS with no feedback is the prevalent opinion. Reduction of additional stimulatory signal delivered to the brain is the advantage of using feedback. This results in reduction of side effects caused by the excessive stimulation intensity. In fact, the stimulatory intensity of controllers is decreased proportional to reduction of hand tremor. The objective of this study is to design a new controller structure to decrease three indicators: (i) the hand tremor; (ii) the level of delivered stimulation in disease condition; and (iii) the ratio of the level of delivered stimulation in health condition to disease condition. For this purpose, the authors offer a new closed-loop control structure to stimulate two areas of BG simultaneously. One area (STN: subthalamic nucleus) is stimulated by an adaptive controller with feedback error learning. The other area (GPi: globus pallidus internal) is stimulated by a partial state feedback (PSF) controller. Considering the three indicators, the results show that, stimulating two areas simultaneously leads to better performance compared with stimulating one area only. It is shown that both PSF and adaptive controllers are robust regarding system parameter uncertainties. In addition, a method is proposed to update the parameters of the BG model in real time. As a result, the parameters of the controllers can be updated based on the new parameters of the BG model.
The role of pain catastrophizing in experimental pain perception.
Kristiansen, Frederik L; Olesen, Anne E; Brock, Christina; Gazerani, Parisa; Petrini, Laura; Mogil, Jeffrey S; Drewes, Asbjørn M
2014-03-01
Pain is a subjective experience influenced by multiple factors, and tremendous variety within individuals is present. To evaluate emotional state of pain, catastrophizing score can be used. This study investigated pain catastrophizing ratings in association with experimental pain perception. Experimental pain was induced using thermal heat and cold stimulation of skin, mechanical stimulation of muscle and bone, and thermal, mechanical, and electrical stimulation of the gastrointestinal tract in healthy participants (N = 41). Prior to experimental sessions, a pain catastrophizing questionnaire was filled out by each participant. Based on the median catastophizing score, participants were divided into two groups: noncatastrophizers and low-catastrophizers. No significant difference was found between low-catastrophizers and noncatastrophizers in thermal heat stimulation of skin, mechanical stimulation of muscle and bone, and rectal electrical stimulation (All P > 0.05). Low-catastrophizers were more sensitive to visceral thermal stimulation (4.7%, P = 0.02) and visceral mechanical stimulation (29.7%, P = 0.03). For participants that completed the 120 seconds ice water stimulation, noncatastrophizers reported 13.8% less pain than low-catastrophizers (P = 0.02). A positive correlation between PCS score and pain perception on cold pressor test was found (r = 0.4, P = 0.02). By extrapolating data, further analysis of the total group was performed and no differences (both P > 0.05) were observed. Even small increments in pain catastrophizing score can influence pain perception to deep and tonic stimulations. Catatrophizing may partly explain the variability found in experimental pain studies. © 2013 World Institute of Pain.
Fairchild, Mallika; Kim, Seung-Jae; Iarkov, Alex; Abbas, James J.; Jung, Ranu
2010-01-01
The long-term objective of this work is to understand the mechanisms by which electrical stimulation based movement therapies may harness neural plasticity to accelerate and enhance sensorimotor recovery after incomplete spinal cord injury (iSCI). An adaptive neuromuscular electrical stimulation (aNMES) paradigm was implemented in adult Long Evans rats with thoracic contusion injury (T8 vertebral level, 155±2 Kdyne). In lengthy sessions with lightly anesthetized animals, hip flexor and extensor muscles were stimulated using an aNMES control system in order to generate desired hip movements. The aNMES control system, which used a pattern generator/pattern shaper structure, adjusted pulse amplitude to modulate muscle force in order to control hip movement. An intermittent stimulation paradigm was used (5-cycles/set; 20-second rest between sets; 100 sets). In each cycle, hip rotation caused the foot plantar surface to contact a stationary brush for appropriately timed cutaneous input. Sessions were repeated over several days while the animals recovered from injury. Results indicated that aNMES automatically and reliably tracked the desired hip trajectory with low error and maintained range of motion with only gradual increase in stimulation during the long sessions. Intermittent aNMES thus accounted for the numerous factors that can influence the response to NMES: electrode stability, excitability of spinal neural circuitry, non-linear muscle recruitment, fatigue, spinal reflexes due to cutaneous input, and the endogenous recovery of the animals. This novel aNMES application in the iSCI rodent model can thus be used in chronic stimulation studies to investigate the mechanisms of neuroplasticity targeted by NMES-based repetitive movement therapy. PMID:20206164
McCabe, Sean Esteban; Veliz, Phil; Boyd, Carol J.
2016-01-01
Background The age of onset (early vs. late) and context (medical vs. nonmedical) of exposure to stimulant medications for attention-deficit/hyperactivity disorder (ADHD) have been identified as important factors in the addictive potential of these controlled medications. This study examines the role of medical and nonmedical contexts in the association between early exposure to stimulant medications and substance use and substance-related problems among adolescents. Methods A Web-based survey was self-administered by Detroit-area secondary school students (N = 4,755) between the 2009–10 and 2012–13 school years. The sample consisted of 51% females, 62% Whites, 32% African-Americans, and 6% from other racial categories. Results During the study period, an estimated 11.7% of respondents were ever diagnosed with ADHD. Approximately 6.7% (n = 322) of respondents indicated lifetime medical use of prescription stimulants while 2.6% (n = 124) indicated lifetime nonmedical use. The odds of substance use and substance-related problems were significantly lower among those who initiated earlier medical use of stimulant medications relative to later medical initiation. In contrast, the odds of substance use and substance-related problems were significantly greater among those who initiated earlier nonmedical use of stimulant medications relative to later nonmedical initiation. Conclusions More than one in every ten adolescents in this epidemiologically-derived community-based sample was diagnosed with ADHD. This is the first investigation to demonstrate that context (medical vs. nonmedical) plays a critical role in the relationship between early exposure to stimulant medications and the subsequent risk of substance-related problems during adolescence within the same diverse youth sample. PMID:27129621
Activation of lower back muscles via FES for pressure sores prevention in paraplegia: a case study.
Vanoncini, M; Holderbaum, W; Andrews, B J
2010-04-01
The aim of this paper is to show the feasibility of the use of functional electrical stimulation (FES) applied to the lower back muscles for pressure sores prevention in paraplegia. The hypothesis under study is that FES induces a change in the pressure distribution on the contact area during sitting. Tests were conducted on a paraplegic subject (T5), sitting on a standard wheelchair and cushion. Trunk extensors (mainly the erector spinae) were stimulated using surface electrodes placed on the skin. A pressure mapping system was used to measure the pressure on the sitting surface in four situations: (a) no stimulation; (b) stimulation on one side of the spine only; (c) stimulation on both sides, at different levels; and (d) stimulation at the same level on both sides, during pressure-relief manoeuvres. A session of prolonged stimulation was also conducted. The experimental results show that the stimulation of the erector spinae on one side of the spine can induce a trunk rotation on the sagittal plane, which causes a change in the pressure distribution. A decrease of pressure on the side opposite to the stimulation was recorded. The phenomenon is intensified when different levels of stimulation are applied to the two sides, and such change can be sustained for a considerable time (around 5 minutes). The stimulation did not induce changes during pressure-relief manoeuvres. Finally, from this research we can conclude that the stimulation of the trunk extensors can be a useful tool for pressure sores prevention, and can potentially be used in a routine for pressure sores prevention based on periodical weight shifts.
NASA Astrophysics Data System (ADS)
Schmidt, Christian; Wagner, Sven; Burger, Martin; van Rienen, Ursula; Wolters, Carsten H.
2015-08-01
Objective. Transcranial direct current stimulation (tDCS) is a non-invasive brain stimulation technique to modify neural excitability. Using multi-array tDCS, we investigate the influence of inter-individually varying head tissue conductivity profiles on optimal electrode configurations for an auditory cortex stimulation. Approach. In order to quantify the uncertainty of the optimal electrode configurations, multi-variate generalized polynomial chaos expansions of the model solutions are used based on uncertain conductivity profiles of the compartments skin, skull, gray matter, and white matter. Stochastic measures, probability density functions, and sensitivity of the quantities of interest are investigated for each electrode and the current density at the target with the resulting stimulation protocols visualized on the head surface. Main results. We demonstrate that the optimized stimulation protocols are only comprised of a few active electrodes, with tolerable deviations in the stimulation amplitude of the anode. However, large deviations in the order of the uncertainty in the conductivity profiles could be noted in the stimulation protocol of the compensating cathodes. Regarding these main stimulation electrodes, the stimulation protocol was most sensitive to uncertainty in skull conductivity. Finally, the probability that the current density amplitude in the auditory cortex target region is supra-threshold was below 50%. Significance. The results suggest that an uncertain conductivity profile in computational models of tDCS can have a substantial influence on the prediction of optimal stimulation protocols for stimulation of the auditory cortex. The investigations carried out in this study present a possibility to predict the probability of providing a therapeutic effect with an optimized electrode system for future auditory clinical and experimental procedures of tDCS applications.
Optogenetic activation of neocortical neurons in vivo with a sapphire-based micro-scale LED probe.
McAlinden, Niall; Gu, Erdan; Dawson, Martin D; Sakata, Shuzo; Mathieson, Keith
2015-01-01
Optogenetics has proven to be a revolutionary technology in neuroscience and has advanced continuously over the past decade. However, optical stimulation technologies for in vivo need to be developed to match the advances in genetics and biochemistry that have driven this field. In particular, conventional approaches for in vivo optical illumination have a limitation on the achievable spatio-temporal resolution. Here we utilize a sapphire-based microscale gallium nitride light-emitting diode (μLED) probe to activate neocortical neurons in vivo. The probes were designed to contain independently controllable multiple μLEDs, emitting at 450 nm wavelength with an irradiance of up to 2 W/mm(2). Monte-Carlo stimulations predicted that optical stimulation using a μLED can modulate neural activity within a localized region. To validate this prediction, we tested this probe in the mouse neocortex that expressed channelrhodopsin-2 (ChR2) and compared the results with optical stimulation through a fiber at the cortical surface. We confirmed that both approaches reliably induced action potentials in cortical neurons and that the μLED probe evoked strong responses in deep neurons. Due to the possibility to integrate many optical stimulation sites onto a single shank, the μLED probe is thus a promising approach to control neurons locally in vivo.
Elkind-Hirsch, Karen E; Webster, Bobby W; Brown, Crystal P; Vernon, Michael W
2003-03-01
To evaluate controlled ovarian stimulation cycles using the GnRH antagonist ganirelix in combination with the recombinant FSH, follitropin-beta, in women with polycystic ovary syndrome (PCOS). Prospective, nonrandomized clinical study. Hospital-based infertility practice. Twenty women with PCOS planning to undergo ovarian stimulation. Fasting glucose and insulin levels were used to calculate insulin resistance ratios (FG/I). After pretreatment with oral contraceptives, serum LH levels were determined, and 250 microg ganirelix was administered on cycle day 2. Upon suppression of LH, concurrent ganirelix and follitropin-beta therapy (morning ganirelix and evening follitropin-beta) was started and continued until the day of hCG. Days of stimulation, dose of follitropin-beta, pregnancy, and ongoing pregnancy were compared based on FG/I ratios. One dose of ganirelix effectively suppressed LH levels in all patients. All patients ovulated as documented by a rise in progesterone. Significant differences were observed between the insulin-resistant and non-insulin-resistant groups for both days of stimulation and dose of follitropin-beta. The overall clinical pregnancy rate was 44.4%, with an ongoing pregnancy rate of 27.8%. In this preliminary study, we demonstrate the effectiveness of a concurrent ganirelix and follitropin-beta therapy for ovarian stimulation in women with PCOS.
Image-guided preoperative prediction of pyramidal tract side effect in deep brain stimulation
NASA Astrophysics Data System (ADS)
Baumgarten, C.; Zhao, Y.; Sauleau, P.; Malrain, C.; Jannin, P.; Haegelen, C.
2016-03-01
Deep brain stimulation of the medial globus pallidus is a surgical procedure for treating patients suffering from Parkinson's disease. Its therapeutic effect may be limited by the presence of pyramidal tract side effect (PTSE). PTSE is a contraction time-locked to the stimulation when the current spreading reaches the motor fibers of the pyramidal tract within the internal capsule. The lack of side-effect predictive model leads the neurologist to secure an optimal electrode placement by iterating clinical testing on an awake patient during the surgical procedure. The objective of the study was to propose a preoperative predictive model of PTSE. A machine learning based method called PyMAN (for Pyramidal tract side effect Model based on Artificial Neural network) that accounted for the current of the stimulation, the 3D electrode coordinates and the angle of the trajectory, was designed to predict the occurrence of PTSE. Ten patients implanted in the medial globus pallidus have been tested by a clinician to create a labeled dataset of the stimulation parameters that trigger PTSE. The kappa index value between the data predicted by PyMAN and the labeled data was .78. Further evaluation studies are desirable to confirm whether PyMAN could be a reliable tool for assisting the surgeon to prevent PTSE during the preoperative planning.
Spatial characterization of innervation zones under electrically elicited M-wave.
Zhang, C; Peng, Y; Li, S; Zhou, P; Munoz, A; Tang, D; Zhang, Y
2016-08-01
The three dimensional (3D) innervation zone (IZ) imaging approach (3DIZI) has been developed in our group to localize the IZ of a particular motor unit (MU) from its motor unit action potentials decomposed from high-density surface electromyography (EMG) recordings. In this study, the developed 3DIZI approach was combined with electrical stimulation to investigate global distributions of IZs in muscles from electrically elicited M-wave recordings. Electrical stimulations were applied to the musculocutaneous nerve to activate supramaximal muscle response of the biceps brachii in one healthy subject, and high-density (128 channels) surface EMG signals of the biceps brachii muscles were recorded. The 3DIZI approach was then employed to image the IZ distribution of IZs in the 3D space of the biceps brachii. The performance of the M-wave based 3DIZI approach was evaluated with different stimulation intensities. Results show that the reconstructed IZs under supramaximal stimulation are spatially distributed in the center region of muscle belly which is consistent with previous studies. With sub-maximal stimulation intensity, the imaged IZ centers became more proximally and deeply located. The proposed M-wave based 3DIZI approach demonstrated its capability of imaging global distribution of IZs in muscles, which provide valuable information for clinical applications such as guiding botulinum toxin injection in treating muscle spasticity.
Manafi-Khanian, Bahram; Arendt-Nielsen, Lars; Graven-Nielsen, Thomas
2016-03-01
Cuff pressure stimulation is applicable for assessing deep-tissue pain sensitivity by exciting a variety of deep-tissue nociceptors. In this study, the relative transfer of biomechanical stresses and strains from the cuff via the skin to the muscle and the somatic tissue layers around bones were investigated. Cuff pressure was applied on the lower leg at three different stimulation intensities (mild pressure to pain). Three-dimensional finite element models including bones and three different layers of deep tissues were developed based on magnetic resonance images (MRI). The skin indentation maps at mild pressure, pain threshold, and intense painful stimulations were extracted from MRI and applied to the model. The mean stress under the cuff position around tibia was 4.6, 4.9 and around fibula 14.8, 16.4 times greater than mean stress of muscle surface in the same section at pain threshold and intense painful stimulations, respectively. At the same stimulation intensities, the mean strains around tibia were 36.4, 42.3 % and around fibula 32.9, 35.0 %, respectively, of mean strain on the muscle surface. Assuming strain as the ideal stimulus for nociceptors the results suggest that cuff algometry is less capable to challenge the nociceptors of tissues around bones as compared to more superficially located muscles.
Dethlefs, Nina; Milders, Maarten; Cuayáhuitl, Heriberto; Al-Salkini, Turkey; Douglas, Lorraine
2017-12-01
Currently, an estimated 36 million people worldwide are affected by Alzheimer's disease or related dementias. In the absence of a cure, non-pharmacological interventions, such as cognitive stimulation, which slow down the rate of deterioration can benefit people with dementia and their caregivers. Such interventions have shown to improve well-being and slow down the rate of cognitive decline. It has further been shown that cognitive stimulation in interaction with a computer is as effective as with a human. However, the need to operate a computer often represents a difficulty for the elderly and stands in the way of widespread adoption. A possible solution to this obstacle is to provide a spoken natural language interface that allows people with dementia to interact with the cognitive stimulation software in the same way as they would interact with a human caregiver. This makes the assistive technology accessible to users regardless of their technical skills and provides a fully intuitive user experience. This article describes a pilot study that evaluated the feasibility of computer-based cognitive stimulation through a spoken natural language interface. Prototype software was evaluated with 23 users, including healthy elderly people and people with dementia. Feedback was overwhelmingly positive.
Giordano, S B; Segal, R L; Abelew, T A
2009-01-01
The purpose of this study was to investigate the end-point force trajectories of the fibularis longus (FIB), lateral gastrocnemius (LG) and medial gastrocnemius (MG) muscles. Most information about individual muscle function has come from studies which use models based on electromyographic (EMG) recordings. In this study (N=20 subjects) we used electrical stimulation (20Hz) to elicit activity in individual muscles, recorded the end-point forces at the foot and verified the selectivity of stimulation by using magnetic resonance imaging. Unexpectedly, no significant differences were found between LG and MG force directions. Stimulation of LG and MG resulted in downward and medial or lateral forces depending on the subject. We found FIB end-point forces to be significantly different than those of LG and MG. In all subjects, stimulation of FIB resulted in downward and lateral forces. Based on our results, we suggest that there are multiple factors determining when and whether LG or MG will produce a medial or lateral force and FIB consistently plays a significant role in eversion/abduction and plantarflexion. We suggest that the inter-subject variability we found is not simply an artifact of experimental or technical error but is functionally relevant and should be addressed in future studies and models. PMID:20095454
Control of Abnormal Synchronization in Neurological Disorders
Popovych, Oleksandr V.; Tass, Peter A.
2014-01-01
In the nervous system, synchronization processes play an important role, e.g., in the context of information processing and motor control. However, pathological, excessive synchronization may strongly impair brain function and is a hallmark of several neurological disorders. This focused review addresses the question of how an abnormal neuronal synchronization can specifically be counteracted by invasive and non-invasive brain stimulation as, for instance, by deep brain stimulation for the treatment of Parkinson’s disease, or by acoustic stimulation for the treatment of tinnitus. On the example of coordinated reset (CR) neuromodulation, we illustrate how insights into the dynamics of complex systems contribute to successful model-based approaches, which use methods from synergetics, non-linear dynamics, and statistical physics, for the development of novel therapies for normalization of brain function and synaptic connectivity. Based on the intrinsic multistability of the neuronal populations induced by spike timing-dependent plasticity (STDP), CR neuromodulation utilizes the mutual interdependence between synaptic connectivity and dynamics of the neuronal networks in order to restore more physiological patterns of connectivity via desynchronization of neuronal activity. The very goal is to shift the neuronal population by stimulation from an abnormally coupled and synchronized state to a desynchronized regime with normalized synaptic connectivity, which significantly outlasts the stimulation cessation, so that long-lasting therapeutic effects can be achieved. PMID:25566174
Piber, Dominique; Schultebraucks, Katharina; Mueller, Sven C; Deuter, Christian Eric; Wingenfeld, Katja; Otte, Christian
2016-12-01
Stress hormones such as cortisol are known to influence a wide range of cognitive functions, including hippocampal based spatial memory. In the brain, cortisol acts via two different receptors: the glucocorticoid (GR) and the mineralocorticoid receptor (MR). As the MR has a high density in the hippocampus, we examined the effects of pharmacological MR stimulation on spatial memory. Eighty healthy participants (40 women, 40 men, mean age=23.9years±SD=3.3) completed the virtual Morris Water Maze (vMWM) task to test spatial encoding and spatial memory retrieval after receiving 0.4mg fludrocortisone, a MR agonist, or placebo. There was no effect of MR stimulation on spatial encoding during the vMWM task. However, participants who received fludrocortisone exhibited improved spatial memory retrieval performance. There was neither a main effect of sex nor a sex-by-treatment interaction. In young healthy participants, MR stimulation improved hippocampal based spatial memory retrieval in a virtual Morris Water Maze task. Our study not only confirms the importance of MR function in spatial memory, but suggests beneficial effects of acute MR stimulation on spatial memory retrieval in humans. Copyright © 2016 Elsevier Inc. All rights reserved.
Carbon Nanofiber Nanoelectrodes for Biosensing Applications
NASA Technical Reports Server (NTRS)
Koehne, Jessica Erin
2014-01-01
A sensor platform based on vertically aligned carbon nanofibers (CNFs) has been developed. Their inherent nanometer scale, high conductivity, wide potential window, good biocompatibility and well-defined surface chemistry make them ideal candidates as biosensor electrodes. Here, we report two studies using vertically aligned CNF nanoelectrodes for biomedical applications. CNF arrays are investigated as neural stimulation and neurotransmitter recording electrodes for application in deep brain stimulation (DBS). Polypyrrole coated CNF nanoelectrodes have shown great promise as stimulating electrodes due to their large surface area, low impedance, biocompatibility and capacity for highly localized stimulation. CNFs embedded in SiO2 have been used as sensing electrodes for neurotransmitter detection. Our approach combines a multiplexed CNF electrode chip, developed at NASA Ames Research Center, with the Wireless Instantaneous Neurotransmitter Concentration Sensor (WINCS) system, developed at the Mayo Clinic. Preliminary results indicate that the CNF nanoelectrode arrays are easily integrated with WINCS for neurotransmitter detection in a multiplexed array format. In the future, combining CNF based stimulating and recording electrodes with WINCS may lay the foundation for an implantable smart therapeutic system that utilizes neurochemical feedback control while likely resulting in increased DBS application in various neuropsychiatric disorders. In total, our goal is to take advantage of the nanostructure of CNF arrays for biosensing studies requiring ultrahigh sensitivity, high-degree of miniaturization, and selective biofunctionalization.
Diana, Tanja; Kahaly, George J
2018-05-02
Thyroid stimulating hormone receptor antibodies (TSHR-Ab) cause autoimmune hyperthyroidism and are prevalent in patients with related thyroid eye disease (TED). To provide a historical perspective on TSHR-Ab and to present evidence-based recommendations for clinical contemporary use. The authors review the recent literature pertaining to TSHR-Ab in patients with TED and describe the various immunoassays currently used for detecting TSHR-Ab and their clinical applications. We provide a historical summary and description of the various methods used to detect TSHR-Ab, foremost, the functional TSHR-Ab. Increasing experimental and clinical data demonstrate the clinical usefulness of cell-based bioassays for measurements of functional TSHR-Ab in the diagnosis and management of patients with autoimmune TED and in the characterization of patients with autoimmune-induced hyperthyroidism and hypothyroidism. Thyroid stimulating hormone receptor antibodies, especially the functional stimulating antibodies, are sensitive, specific, and reproducible biomarkers for patients with autoimmune TED and correlate well with clinical disease activity and clinical severity. Unlike competitive-binding assays, bioassays have the advantage of indicating not only the presence of antibodies but also their functional activity and potency. Measurement of TSHR-Ab (especially stimulating antibodies) is a clinically useful tool for the management of patients with TED.
Deep Stimulation at Newberry Volcano EGS Demonstration
NASA Astrophysics Data System (ADS)
Grasso, K.; Cladouhos, T. T.; Petty, S.; Garrison, G. H.; Nordin, Y.; Uddenberg, M.; Swyer, M.
2014-12-01
The Newberry Volcano EGS Demonstration is a 5 year field project designed to demonstrate recent technological advances for engineered geothermal systems (EGS) development. Advances in reservoir stimulation, diverter, and monitoring are being tested in a hot (>300 C), dry well (NWG 55-29) drilled in 2008. These technologies could reduce the cost of electrical power generation. The project began in 2010 with two years of permitting, technical planning, and development of a project-specific Induced Seismicity Mitigation Plan (ISMP), and is funded in part by the Department of Energy. In 2012, the well was hydraulically stimulated with water at pressures below the principle stress for 7 weeks, resulting in hydroshearing. The depth of stimulation was successfully shifted by injection of two pills of Thermally-degradable Zonal Isolation Materials (TZIMs). Injectivity changes, thermal profiles and seismicity indicate that fracture permeability in well NWG 55-29 was enhanced during stimulation. This work successfully demonstrated the viability of large-volume (40,000 m3), low-pressure stimulation coupled with non-mechanical diverter technology, and microseismic monitoring for reservoir mapping. Further analysis and field testing in 2013 indicates further stimulation will be required in order to develop an economically viable reservoir, and is scheduled in 2014. The 2014 stimulation will use improved stimulation and monitoring equipment, better knowledge based on 2012 outcomes, and create a deep EGS reservoir in the hottest part of the wellbore.
Fidelity of an optical memory based on stimulated photon echoes.
Staudt, M U; Hastings-Simon, S R; Nilsson, M; Afzelius, M; Scarani, V; Ricken, R; Suche, H; Sohler, W; Tittel, W; Gisin, N
2007-03-16
We investigated the preservation of information encoded into the relative phase and amplitudes of optical pulses during storage and retrieval in an optical memory based on stimulated photon echo. By interfering photon echoes produced in a single-mode Ti:Er:LiNbO(3) waveguide, we found that decoherence in the medium translates only as loss and not as degradation of information. We measured a visibility for interfering echoes close to 100%. These results may have important implications for future long-distance quantum communication protocols.
Evidence That Graves' Ophthalmopathy Immunoglobulins Do Not Directly Activate IGF-1 Receptors.
Marcus-Samuels, Bernice; Krieger, Christine C; Boutin, Alisa; Kahaly, George J; Neumann, Susanne; Gershengorn, Marvin C
2018-05-01
Graves' ophthalmopathy (GO) pathogenesis involves thyrotropin (TSH) receptor (TSHR)-stimulating autoantibodies. Whether there are autoantibodies that directly stimulate insulin-like growth factor 1 receptors (IGF-1Rs), stimulating insulin-like growth factor receptor antibodies (IGFRAbs), remains controversial. This study attempted to determine whether there are stimulating IGFRAbs in patients with GO. Immunoglobulins (Igs) were purified from normal volunteers (NV-Igs) and patients with GO (GO-Igs). The effects of TSH, IGF-1, NV-Igs, and GO-Igs on pAKT and pERK1/2, members of pathways used by IGF-1R and TSHR, were compared in orbital fibroblasts from GO patients (GOFs) and U2OS-TSHR cells overexpressing TSHRs, and U2OS cells that express TSHRs at very low endogenous levels. U2OS-TSHR and U2OS cells were used because GOFs are not easily manipulated using molecular techniques such as transfection, and U2OS cells because they express TSHRs at levels that do not measurably stimulate signaling. Thus, comparing U2OS-TSHR and U2OS cells permits specifically distinguishing signaling mediated by the TSHR and IGF-1R. In GOFs, all GO-Igs stimulated pERK1/2 formation and 69% stimulated pAKT. In U2OS-TSHR cells, 15% of NV-IGs and 83% of GO-Igs stimulated increases in pERK1/2, whereas all NV-Igs and GO-Igs stimulated increases in pAKT. In U2OS cells, 70% of GO-Igs stimulated small increases in pAKT. Knockdown of IGF-1R caused a 65 ± 6.3% decrease in IGF-1-stimulated pAKT but had no effect on GO-Igs stimulation of pAKT. Thus, GO-Igs contain factor(s) that stimulate pAKT formation. However, this factor(s) does not directly activate IGF-1R. Based on the findings analyzing these two signaling pathways, it is concluded there is no evidence of stimulating IGFRAbs in GO patients.
Hunter, Corey W; Yang, Ajax; Davis, Tim
2017-10-01
While spinal cord stimulation (SCS) has established itself as an accepted and validated treatment for neuropathic pain, there are a number of conditions where it has experienced less, long-term success: post amputee pain (PAP) being one of them. Dorsal root ganglion (DRG) stimulation has shown great promise, particularly in conditions where traditional SCS has fallen short. One major difference between DRG stimulation and traditional SCS is the ability to provide focal stimulation over targeted areas. While this may be a contributing factor to its superiority, it can also be a limitation insofar stimulating the wrong DRG(s) can lead to failure. This is particularly relevant in conditions like PAP where neuroplastic maladaptation occurs causing the pain to deviate from expected patterns, thus creating uncertainty and variability in predicting targets for stimulation. We propose selective radiofrequency (RF) stimulation of the DRG as a method for preoperatively predicting targets for neuromodulation in patients with PAP. We present four patients with PAP of the lower extremities. RF stimulation was used to selectively stimulate individual DRG's, creating areas of paresthesias to see which most closely correlated/overlapped with the painful area(s). RF stimulation to the DRG's that resulted in the desirable paresthesia coverage in the residual or the missing limb(s) was recorded as "positive." Trial DRG leads were placed based on the positive RF stimulation findings. In each patient, stimulating one or more DRG(s) produced paresthesias patterns that were contradictory to know dermatomal patterns. Upon completion of a one-week trial all four patients reported 60-90% pain relief, with coverage over the painful areas, and opted for permanent implant. Mapping the DRG via RF stimulation appears to provide improved accuracy for determining lead placement in the setting of PAP where pain patterns are known to deviate from conventional dermatomal mapping. © 2017 International Neuromodulation Society.
Zhang, Shizhen; Zhou, Peizhi; Jiang, Shu; Wang, Wei; Li, Peng
2016-12-01
Deep brain stimulation (DBS) of the subthalamic nucleus is an effective treatment for advanced Parkinson disease (PD). However, achieving ideal outcomes by conventional programming can be difficult in some patients, resulting in suboptimal control of PD symptoms and stimulation-induced adverse effects. Interleaving stimulation (ILS) is a newer programming technique that can individually optimize the stimulation area, thereby improving control of PD symptoms while alleviating stimulation-induced side effects after conventional programming fails to achieve the desired results. We retrospectively reviewed PD patients who received DBS programming during the previous 4 years in our hospital. We collected clinical and demographic data from 12 patients who received ILS because of incomplete alleviation of PD symptoms or stimulation-induced adverse effects after conventional programming had proven ineffective or intolerable. Appropriate lead location was confirmed with postoperative reconstruction images. The rationale and clinical efficacy of ILS was analyzed. We divided our patients into 4 groups based on the following symptoms: stimulation-induced dysarthria and choreoathetoid dyskinesias, gait disturbance, and incomplete control of parkinsonism. After treatment with ILS, patients showed satisfactory improvement in PD symptoms and alleviation of stimulation-induced side effects, with a mean improvement in Unified PD Rating Scale motor scores of 26.9%. ILS is a newer choice and effective programming strategy to maximize symptom control in PD while decreasing stimulation-induced adverse effects when conventional programming fails to achieve satisfactory outcome. However, we should keep in mind that most DBS patients are routinely treated with conventional stimulation and that not all patients benefit from ILS. ILS is not recommended as the first choice of programming, and it is recommended only when patients have unsatisfactory control of PD symptoms or stimulation-induced side effects after multiple treatments with conventional stimulation. A return to conventional stimulation may be required if ILS induces new side effects or the needs of the patient change.
Zhang, Shizhen; Zhou, Peizhi; Jiang, Shu; Wang, Wei; Li, Peng
2016-01-01
Abstract Background: Deep brain stimulation (DBS) of the subthalamic nucleus is an effective treatment for advanced Parkinson disease (PD). However, achieving ideal outcomes by conventional programming can be difficult in some patients, resulting in suboptimal control of PD symptoms and stimulation-induced adverse effects. Interleaving stimulation (ILS) is a newer programming technique that can individually optimize the stimulation area, thereby improving control of PD symptoms while alleviating stimulation-induced side effects after conventional programming fails to achieve the desired results. Methods: We retrospectively reviewed PD patients who received DBS programming during the previous 4 years in our hospital. We collected clinical and demographic data from 12 patients who received ILS because of incomplete alleviation of PD symptoms or stimulation-induced adverse effects after conventional programming had proven ineffective or intolerable. Appropriate lead location was confirmed with postoperative reconstruction images. The rationale and clinical efficacy of ILS was analyzed. Results: We divided our patients into 4 groups based on the following symptoms: stimulation-induced dysarthria and choreoathetoid dyskinesias, gait disturbance, and incomplete control of parkinsonism. After treatment with ILS, patients showed satisfactory improvement in PD symptoms and alleviation of stimulation-induced side effects, with a mean improvement in Unified PD Rating Scale motor scores of 26.9%. Conclusions: ILS is a newer choice and effective programming strategy to maximize symptom control in PD while decreasing stimulation-induced adverse effects when conventional programming fails to achieve satisfactory outcome. However, we should keep in mind that most DBS patients are routinely treated with conventional stimulation and that not all patients benefit from ILS. ILS is not recommended as the first choice of programming, and it is recommended only when patients have unsatisfactory control of PD symptoms or stimulation-induced side effects after multiple treatments with conventional stimulation. A return to conventional stimulation may be required if ILS induces new side effects or the needs of the patient change. PMID:27930569
Optogenetic stimulation of multiwell MEA plates for neural and cardiac applications
NASA Astrophysics Data System (ADS)
Clements, Isaac P.; Millard, Daniel C.; Nicolini, Anthony M.; Preyer, Amanda J.; Grier, Robert; Heckerling, Andrew; Blum, Richard A.; Tyler, Phillip; McSweeney, K. M.; Lu, Yi-Fan; Hall, Diana; Ross, James D.
2016-03-01
Microelectrode array (MEA) technology enables advanced drug screening and "disease-in-a-dish" modeling by measuring the electrical activity of cultured networks of neural or cardiac cells. Recent developments in human stem cell technologies, advancements in genetic models, and regulatory initiatives for drug screening have increased the demand for MEA-based assays. In response, Axion Biosystems previously developed a multiwell MEA platform, providing up to 96 MEA culture wells arrayed into a standard microplate format. Multiwell MEA-based assays would be further enhanced by optogenetic stimulation, which enables selective excitation and inhibition of targeted cell types. This capability for selective control over cell culture states would allow finer pacing and probing of cell networks for more reliable and complete characterization of complex network dynamics. Here we describe a system for independent optogenetic stimulation of each well of a 48-well MEA plate. The system enables finely graded control of light delivery during simultaneous recording of network activity in each well. Using human induced pluripotent stem cell (hiPSC) derived cardiomyocytes and rodent primary neuronal cultures, we demonstrate high channel-count light-based excitation and suppression in several proof-of-concept experimental models. Our findings demonstrate advantages of combining multiwell optical stimulation and MEA recording for applications including cardiac safety screening, neural toxicity assessment, and advanced characterization of complex neuronal diseases.
Lee, S Y; Lee, K J
2001-04-01
To develop a personal optically stimulated luminescence (OSL) dosimetry system for mixed radiation fields using alpha-Al2O3:C, a discriminating badge filter system was designed by taking advantage of its optically stimulable properties and energy dependencies. This was done by designing a multi-element badge system for powder layered alpha-Al2O3:C material and an optical reader system based on high-intensity blue light-emitting diode (LED). The design of the multielement OSL dosimeter badge system developed allows the measurement of a personal dose equivalent value Hp(d) in mixed radiation fields of beta and gamma. Dosimetric properties of the personal OSL dosimeter badge system investigated here were the dose response, energy response and multi-readability. Based on the computational simulations and experiments of the proposed dosimeter design, it was demonstrated that a multi-element dosimeter system with an OSL technology based on alpha-Al2O3:C is suitable to obtain personal dose equivalent information in mixed radiation fields.
Wang, Jingxuan; Lu, Jianren; Tian, Lan
2016-06-01
The purpose of this study was to evaluate the effects of fiberoptic collimation technique on auditory neural stimulation in the cochlea with 808 nm wavelength lasers. Recently, the pulsed near-infrared lasers in the 800-1000 nm wavelength range have been investigated as an emerging technique to trigger auditory neural response in the cochlea. A laser beam divergence in the optical stimulation pathway exists, which may affect stimulation efficiency and spatial selectivity. The fiberoptic collimation technique was proposed for cochlear neuron stimulation, and the C-lens element was designed as the collimation structure. The spiral ganglion cells in deafened guinea pigs' cochlea were irradiated with collimated and uncollimated near-infrared lasers. Optically evoked auditory brainstem response (OABR) under the two laser output modes were recorded. Laser with the collimation technique evoked an average 58% higher OABR amplitude than the uncollimated laser output. In addition, the collimated laser setup consumed on average 35.2% of laser energy compared with the uncollimated laser when evoking the same OABR amplitude. The fiberoptic collimation technique improved stimulation efficiency and reduced stimulating energy consumption in near-infrared neural stimulation in cochlea. The positive effects of laser collimation technique could benefit further research in optically based cochlear implants.
Doyle, Michael L; Tian, Shin-Shay; Miller, Stephen G; Kessler, Linda; Baker, Audrey E; Brigham-Burke, Michael R; Dillon, Susan B; Duffy, Kevin J; Keenan, Richard M; Lehr, Ruth; Rosen, Jon; Schneeweis, Lumelle A; Trill, John; Young, Peter R; Luengo, Juan I; Lamb, Peter
2003-03-14
Granulocyte colony-stimulating factor regulates neutrophil production by binding to a specific receptor, the granulocyte colony-stimulating factor receptor, expressed on cells of the granulocytic lineage. Recombinant forms of granulocyte colony-stimulating factor are used clinically to treat neutropenias. As part of an effort to develop granulocyte colony-stimulating factor mimics with the potential for oral bioavailability, we previously identified a nonpeptidyl small molecule (SB-247464) that selectively activates murine granulocyte colony-stimulating factor signal transduction pathways and promotes neutrophil formation in vivo. To elucidate the mechanism of action of SB-247464, a series of cell-based and biochemical assays were performed. The activity of SB-247464 is strictly dependent on the presence of zinc ions. Titration microcalorimetry experiments using a soluble murine granulocyte colony-stimulating factor receptor construct show that SB-247464 binds to the extracellular domain of the receptor in a zinc ion-dependent manner. Analytical ultracentrifugation studies demonstrate that SB-247464 induces self-association of the N-terminal three-domain fragment in a manner that is consistent with dimerization. SB-247464 induces internalization of granulocyte colony-stimulating factor receptor on intact cells, consistent with a mechanism involving receptor oligomerization. These data show that small nonpeptidyl compounds are capable of selectively binding and inducing productive oligomerization of cytokine receptors.
New Treatment Strategies of Depression: Based on Mechanisms Related to Neuroplasticity
Lane, Hsien-Yuan
2017-01-01
Major depressive disorder is a severe and complex mental disorder. Impaired neurotransmission and disrupted signalling pathways may influence neuroplasticity, which is involved in the brain dysfunction in depression. Traditional neurobiological theories of depression, such as monoamine hypothesis, cannot fully explain the whole picture of depressive disorders. In this review, we discussed new treatment directions of depression, including modulation of glutamatergic system and noninvasive brain stimulation. Dysfunction of glutamatergic neurotransmission plays an important role in the pathophysiology of depression. Ketamine, an N-methyl-D-aspartate (NMDA) receptor antagonist, has rapid and lasting antidepressive effects in previous studies. In addition to ketamine, other glutamatergic modulators, such as sarcosine, also show potential antidepressant effect in animal models or clinical trials. Noninvasive brain stimulation is another new treatment strategy beyond pharmacotherapy. Growing evidence has demonstrated that superficial brain stimulations, such as transcranial magnetic stimulation, transcranial direct current stimulation, cranial electrotherapy stimulation, and magnetic seizure therapy, can improve depressive symptoms. The antidepressive effect of these brain stimulations may be through modulating neuroplasticity. In conclusion, drugs that modulate neurotransmission via NMDA receptor and noninvasive brain stimulation may provide new directions of treatment for depression. Furthermore, exploring the underlying mechanisms will help in developing novel therapies for depression in the future. PMID:28491480
A population-based study of salivary lysozyme concentrations and candidal counts.
Yeh, C K; Dodds, M W; Zuo, P; Johnson, D A
1997-01-01
The relationship between salivary lysozyme concentration and oral candida load was examined in 595 adults. Unstimulated whole saliva, and citrate-stimulated parotid and submandibular/sublingual saliva were collected from each participant. Candida colony-forming units (c.f.u.) in unstimulated whole saliva were determined. An enzyme-linked immunosorbent assay for lysozyme using commercially available antibodies was developed. This assay showed a linear relation of salivary lysozyme concentrations from 0.5 to 4.0 ng/ml. Significant negative relations were observed between lysozyme concentration and flow rate: r = -0.16 (p < 0.001) for stimulated parotid and r = -0.22 (p < 0.0001) for stimulated submandibular/sublingual saliva. The lysozyme concentration in stimulated submandibular/sublingual saliva was higher in males than in female, but no sex difference was observed for stimulated parotid saliva. The lysozyme concentration of stimulated parotid saliva was positively correlated with candida counts (r = 0.18: p < 0.005). Further study of groups according to their levels of candida in whole saliva revealed that lysozyme concentrations were higher in the high candida (> or = 1000 c.f.u./ml) group than in the zero and moderate candida categories in stimulated parotid saliva (p < 0.001): there were no concentration differences in stimulated submandibular/sublingual saliva. These results suggest that parotid lysozyme concentration increases as candida load increases.
Vagus Nerve Stimulation for Electrographic Status Epilepticus in Slow-Wave Sleep.
Carosella, Christopher M; Greiner, Hansel M; Byars, Anna W; Arthur, Todd M; Leach, James L; Turner, Michele; Holland, Katherine D; Mangano, Francesco T; Arya, Ravindra
2016-07-01
Electrographic status epilepticus in slow sleep or continuous spike and waves during slow-wave sleep is an epileptic encephalopathy characterized by seizures, neurocognitive regression, and significant activation of epileptiform discharges during nonrapid eye movement sleep. There is no consensus on the diagnostic criteria and evidence-based optimal treatment algorithm for children with electrographic status epilepticus in slow sleep. We describe a 12-year-old girl with drug-resistant electrographic status epilepticus in slow wave sleep that was successfully treated with vagus nerve stimulation. Her clinical presentation, presurgical evaluation, decision-making, and course after vagus nerve stimulator implantation are described in detail. After vagus nerve stimulator implantation, the girl remained seizure free for more than a year, resolved the electrographic status epilepticus in slow sleep pattern on electroencephalography, and exhibited significant cognitive improvement. Vagus nerve stimulation may be considered for electrographic status epilepticus in slow sleep. Copyright © 2016 Elsevier Inc. All rights reserved.
Infrared light excites cells by changing their electrical capacitance
Shapiro, Mikhail G.; Homma, Kazuaki; Villarreal, Sebastian; Richter, Claus-Peter; Bezanilla, Francisco
2012-01-01
Optical stimulation has enabled important advances in the study of brain function and other biological processes, and holds promise for medical applications ranging from hearing restoration to cardiac pace making. In particular, pulsed laser stimulation using infrared wavelengths >1.5 μm has therapeutic potential based on its ability to directly stimulate nerves and muscles without any genetic or chemical pre-treatment. However, the mechanism of infrared stimulation has been a mystery, hindering its path to the clinic. Here we show that infrared light excites cells through a novel, highly general electrostatic mechanism. Infrared pulses are absorbed by water, producing a rapid local increase in temperature. This heating reversibly alters the electrical capacitance of the plasma membrane, depolarizing the target cell. This mechanism is fully reversible and requires only the most basic properties of cell membranes. Our findings underscore the generality of pulsed infrared stimulation and its medical potential. PMID:22415827
Development and positioning reliability of a TMS coil holder for headache research.
Chronicle, Edward P; Pearson, A Jane; Matthews, Cheryl
2005-01-01
Accurate and reproducible coil positioning is important for headache research using transcranial magnetic stimulation protocols. We aimed to design a transcranial magnetic stimulation coil holder and demonstrate reliability of test-retest coil positioning. A coil holder was developed and manufactured according to three principles of stability, durability, and three-dimensional positional accuracy. Reliability of coil positioning was assessed by stimulating over the motor cortex of four neurologically normal subjects and recording finger muscle responses, both at a test phase and a retest phase several hours later. In all four subjects, repositioning of the transcranial magnetic stimulation coil solely on the basis of coil holder coordinates was accurate to within 2 mm. The coil holder demonstrated good test-retest reliability of coil positioning, and is thus a promising tool for transcranial magnetic stimulation-based headache research, particularly studies of prophylactic drug effect where several laboratory visits with identical coil positioning are necessary.
2013-01-01
Background Torso-based vibrotactile feedback may significantly reduce postural sway in balance-compromised adults during quiet standing or in response to perturbations. However, natural non-volitional postural responses to vibrotactile stimulation applied to the torso remain unknown. Methods The primary goal of this study was to determine, for two types of actuators (tactors) and in the absence of instruction, whether vibrotactile stimulation induces a directional postural shift as a function of stimulation location. Eleven healthy young adults (20 – 29 years old) were asked to maintain an upright erect posture with feet hip-width apart and eyes closed. Two types of tactors, Tactaid and C2, which differ in design and stimulation strength, were placed on the skin over the right and left external oblique, internal oblique, and erector spinae muscles in a horizontal plane corresponding approximately to the L4/L5 level. Each tactor of the same type was activated twice randomly for each individual location and twice simultaneously for all locations at a frequency of 250 Hz for a period of 5 s. Results Vibration applied over the internal oblique and erector spinae muscle locations induced a postural shift in the direction of the stimulation regardless of the tactor type. For the aforementioned four locations, the root-mean-square (RMS) and power spectral density (PSD) of the body sway in both the A/P and M/L directions were also significantly greater during the vibration than before or after, and were greater for the C2 tactors than for the Tactaid tactors. However, simultaneous activation of all tactors or those over the external oblique muscle locations did not produce significant postural responses regardless of the tactor type. Conclusion The results suggest that the use of a torso-based vibrotactile sensory augmentation display should carefully consider the tactor type as well as the instruction of corrective movements. Attractive instructional cues (“move in the direction of the vibration”) are compatible with the observed non-volitional response to stimulation and may facilitate postural adjustments during vibrotactile biofeedback balance applications. PMID:23406013
Age-dependent effects of brain stimulation on network centrality.
Antonenko, Daria; Nierhaus, Till; Meinzer, Marcus; Prehn, Kristin; Thielscher, Axel; Ittermann, Bernd; Flöel, Agnes
2018-04-18
Functional magnetic resonance imaging (fMRI) studies have suggested that advanced age may mediate the effects of transcranial direct current stimulation (tDCS) on brain function. However, studies directly comparing neural tDCS effects between young and older adults are scarce and limited to task-related imaging paradigms. Resting-state (rs-) fMRI, that is independent of age-related differences in performance, is well suited to investigate age-associated differential neural tDCS effects. Three "online" tDCS conditions (anodal, cathodal, sham) were compared in a cross-over, within-subject design, in 30 young and 30 older adults. Active stimulation targeted the left sensorimotor network (active electrode over left sensorimotor cortex with right supraorbital reference electrode). A graph-based rs-fMRI data analysis approach (eigenvector centrality mapping) and complementary seed-based analyses characterized neural tDCS effects. An interaction between anodal tDCS and age group was observed. Specifically, centrality in bilateral paracentral and posterior regions (precuneus, superior parietal cortex) was increased in young, but decreased in older adults. Seed-based analyses revealed that these opposing patterns of tDCS-induced centrality modulation originated from differential effects of tDCS on functional coupling of the stimulated left paracentral lobule. Cathodal tDCS did not show significant effects. Our study provides first evidence for differential tDCS effects on neural network organization in young and older adults. Anodal stimulation mainly affected coupling of sensorimotor with ventromedial prefrontal areas in young and decoupling with posteromedial areas in older adults. Copyright © 2018 Elsevier Inc. All rights reserved.
Huang, Wei-Chen; Lo, Yu-Chih; Chu, Chao-Yi; Lai, Hsin-Yi; Chen, You-Yin; Chen, San-Yuan
2017-04-01
Chronic brain stimulation has become a promising physical therapy with increased efficacy and efficiency in the treatment of neurodegenerative diseases. The application of deep brain electrical stimulation (DBS) combined with manganese-enhanced magnetic resonance imaging (MEMRI) provides an unbiased representation of the functional anatomy, which shows the communication between areas of the brain responding to the therapy. However, it is challenging for the current system to provide a real-time high-resolution image because the incorporated MnCl 2 solution through microinjection usually results in image blurring or toxicity due to the uncontrollable diffusion of Mn 2+ . In this study, we developed a new type of conductive nanogel-based neural interface composed of amphiphilic chitosan-modified poly(3,4 -ethylenedioxythiophene) (PMSDT) that can exhibit biomimic structural/mechanical properties and ionic/electrical conductivity comparable to that of Au. More importantly, the PMSDT enables metal-ligand bonding with Mn 2+ ions, so that the system can release Mn 2+ ions rather than MnCl 2 solution directly and precisely controlled by electrical stimulation (ES) to achieve real-time high-resolution MEMRI. With the integration of PMSDT nanogel-based coating in polyimide-based microelectrode arrays, the post-implantation DBS enables frequency-dependent MR imaging in vivo, as well as small focal imaging in response to channel site-specific stimulation on the implant. The MR imaging of the implanted brain treated with 5-min electrical stimulation showed a thalamocortical neuronal pathway after 36 h, confirming the effective activation of a downstream neuronal circuit following DBS. By eliminating the susceptibility to artifact and toxicity, this system, in combination with a MR-compatible implant and a bio-compliant neural interface, provides a harmless and synchronic functional anatomy for DBS. The study demonstrates a model of MEMRI-functionalized DBS based on functional neural interface engineering and controllable delivery technology, which can be utilized in more detailed exploration of the functional anatomy in the treatment of neurodegenerative diseases. Copyright © 2017 Elsevier Ltd. All rights reserved.
Kenney, Laurence P; Heller, Ben W; Barker, Anthony T; Reeves, Mark L; Healey, Jamie; Good, Timothy R; Cooper, Glen; Sha, Ning; Prenton, Sarah; Liu, Anmin; Howard, David
2016-11-01
Functional electrical stimulation has been shown to be a safe and effective means of correcting foot drop of central neurological origin. Current surface-based devices typically consist of a single channel stimulator, a sensor for determining gait phase and a cuff, within which is housed the anode and cathode. The cuff-mounted electrode design reduces the likelihood of large errors in electrode placement, but the user is still fully responsible for selecting the correct stimulation level each time the system is donned. Researchers have investigated different approaches to automating aspects of setup and/or use, including recent promising work based on iterative learning techniques. This paper reports on the design and clinical evaluation of an electrode array-based FES system for the correction of drop foot, ShefStim. The paper reviews the design process from proof of concept lab-based study, through modelling of the array geometry and interface layer to array search algorithm development. Finally, the paper summarises two clinical studies involving patients with drop foot. The results suggest that the ShefStim system with automated setup produces results which are comparable with clinician setup of conventional systems. Further, the final study demonstrated that patients can use the system without clinical supervision. When used unsupervised, setup time was 14min (9min for automated search plus 5min for donning the equipment), although this figure could be reduced significantly with relatively minor changes to the design. Copyright © 2016 IPEM. Published by Elsevier Ltd. All rights reserved.
Ruffini, Giulio; Fox, Michael D; Ripolles, Oscar; Miranda, Pedro Cavaleiro; Pascual-Leone, Alvaro
2014-04-01
Recently, multifocal transcranial current stimulation (tCS) devices using several relatively small electrodes have been used to achieve more focal stimulation of specific cortical targets. However, it is becoming increasingly recognized that many behavioral manifestations of neurological and psychiatric disease are not solely the result of abnormality in one isolated brain region but represent alterations in brain networks. In this paper we describe a method for optimizing the configuration of multifocal tCS for stimulation of brain networks, represented by spatially extended cortical targets. We show how, based on fMRI, PET, EEG or other data specifying a target map on the cortical surface for excitatory, inhibitory or neutral stimulation and a constraint on the maximal number of electrodes, a solution can be produced with the optimal currents and locations of the electrodes. The method described here relies on a fast calculation of multifocal tCS electric fields (including components normal and tangential to the cortical boundaries) using a five layer finite element model of a realistic head. Based on the hypothesis that the effects of current stimulation are to first order due to the interaction of electric fields with populations of elongated cortical neurons, it is argued that the optimization problem for tCS stimulation can be defined in terms of the component of the electric field normal to the cortical surface. Solutions are found using constrained least squares to optimize current intensities, while electrode number and their locations are selected using a genetic algorithm. For direct current tCS (tDCS) applications, we provide some examples of this technique using an available tCS system providing 8 small Ag/AgCl stimulation electrodes. We demonstrate the approach both for localized and spatially extended targets defined using rs-fcMRI and PET data, with clinical applications in stroke and depression. Finally, we extend these ideas to more general stimulation protocols, such as alternating current tCS (tACS). Copyright © 2013 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pai, V.J.
1978-01-01
In order to combat falling productivity and increased water production in the W. Flowers and Guest (Canyon Sand) fields, a new approach to stimulation technique and fluid had to be initiated. It was suspected that many pre-1975 frac jobs probably were lost into unproductive zones resulting in very little stimulation of the actual pay section. To combat this situation, the frac fluid was changed to a very high viscosity cross-linked CMC-based polymer gel. The base fluid was 2% KCl water treated with de-emulsifiers. A detailed computerized study was conducted to determine a near optimum treatment design. Fluid volumes were selectedmore » based on frac lengths, which provided the most economically feasible productivity increase ratios (J/J/sub 0/), and proppant concentrations were analyzed so as to afford the optimum permeability contrasts. Sand concentrations were increased, and 10-20 mesh sand was used.« less
Assessing Pictures through Children's Responses.
ERIC Educational Resources Information Center
Legenza, Alice; Knafle, June D.
Two studies concerning the language-stimulation value of pictures for children were conducted. The first study tested the validity of a formula that classifies pictures as having high, medium, or low potency, based on the amount of language they stimulate in viewers. (The formula takes into account factors such as the number of animals, people,…
ERIC Educational Resources Information Center
Clark, Heather; Lazarus, Cathy; Arvedson, Joan; Schooling, Tracy; Frymark, Tobi
2009-01-01
Purpose: To systematically review the literature examining the effects of neuromuscular electrical stimulation (NMES) on swallowing and neural activation. The review was conducted as part of a series examining the effects of oral motor exercises (OMEs) on speech, swallowing, and neural activation. Method: A systematic search was conducted to…
David W. P. Manning; Amy D. Rosemond; Vladislav Gulis; Jonathan P. Benstead; John S. Kominoski; John C. Maerz
2016-01-01
Nutrient enrichment of detritus-based streams increases detrital resource quality for consumers and stimulates breakdown rates of particulate organic carbon (C). The relative importance of dissolved inorganic nitrogen (N) vs. phosphorus (P) for detrital quality and their effects on microbial- vs. detritivore-mediated detrital breakdown are poorly understood....
Innate immunological function of TH2 cells in vivo
USDA-ARS?s Scientific Manuscript database
Th2 cells produce IL-13 when stimulated by papain or house dust mites (HDM) and induce eosinophilic inflammation. This innate response of cells of the adaptive immune system is dependent on IL-33-, not T cell receptor-, based stimulation. While type 2 innate lymphoid cells (ILC2s) are the dominant ...
The Illicit Use of Prescription Stimulants on College Campuses
ERIC Educational Resources Information Center
Bavarian, Niloofar; Flay, Brian R.; Ketcham, Patricia L.; Smit, Ellen
2015-01-01
The illicit use of prescription stimulants (IUPS) is a substance use behavior that remains prevalent on college campuses. As theory can guide research and practice, we provide a systematic review of the college-based IUPS epidemiological literature guided by one ecological framework, the theory of triadic influence (TTI). We aim to assess…
Grant, Peadar F; Lowery, Madeleine M
2013-07-01
A new model of deep brain stimulation (DBS) is presented that integrates volume conduction effects with a neural model of pathological beta-band oscillations in the cortico-basal ganglia network. The model is used to test the clinical hypothesis that closed-loop control of the amplitude of DBS may be possible, based on the average rectified value of beta-band oscillations in the local field potential. Simulation of closed-loop high-frequency DBS was shown to yield energy savings, with the magnitude of the energy saved dependent on the strength of coupling between the subthalamic nucleus and the remainder of the cortico-basal ganglia network. When closed-loop DBS was applied to a strongly coupled cortico-basal ganglia network, the stimulation energy delivered over a 480 s period was reduced by up to 42%. Greater energy reductions were observed for weakly coupled networks, as the stimulation amplitude reduced to zero once the initial desynchronization had occurred. The results provide support for the application of closed-loop high-frequency DBS based on electrophysiological biomarkers.
Model-based iterative learning control of Parkinsonian state in thalamic relay neuron
NASA Astrophysics Data System (ADS)
Liu, Chen; Wang, Jiang; Li, Huiyan; Xue, Zhiqin; Deng, Bin; Wei, Xile
2014-09-01
Although the beneficial effects of chronic deep brain stimulation on Parkinson's disease motor symptoms are now largely confirmed, the underlying mechanisms behind deep brain stimulation remain unclear and under debate. Hence, the selection of stimulation parameters is full of challenges. Additionally, due to the complexity of neural system, together with omnipresent noises, the accurate model of thalamic relay neuron is unknown. Thus, the iterative learning control of the thalamic relay neuron's Parkinsonian state based on various variables is presented. Combining the iterative learning control with typical proportional-integral control algorithm, a novel and efficient control strategy is proposed, which does not require any particular knowledge on the detailed physiological characteristics of cortico-basal ganglia-thalamocortical loop and can automatically adjust the stimulation parameters. Simulation results demonstrate the feasibility of the proposed control strategy to restore the fidelity of thalamic relay in the Parkinsonian condition. Furthermore, through changing the important parameter—the maximum ionic conductance densities of low-threshold calcium current, the dominant characteristic of the proposed method which is independent of the accurate model can be further verified.
SPAIDE: A Real-time Research Platform for the Clarion CII/90K Cochlear Implant
NASA Astrophysics Data System (ADS)
Van Immerseel, L.; Peeters, S.; Dykmans, P.; Vanpoucke, F.; Bracke, P.
2005-12-01
SPAIDE ( sound-processing algorithm integrated development environment) is a real-time platform of Advanced Bionics Corporation (Sylmar, Calif, USA) to facilitate advanced research on sound-processing and electrical-stimulation strategies with the Clarion CII and 90K implants. The platform is meant for testing in the laboratory. SPAIDE is conceptually based on a clear separation of the sound-processing and stimulation strategies, and, in specific, on the distinction between sound-processing and stimulation channels and electrode contacts. The development environment has a user-friendly interface to specify sound-processing and stimulation strategies, and includes the possibility to simulate the electrical stimulation. SPAIDE allows for real-time sound capturing from file or audio input on PC, sound processing and application of the stimulation strategy, and streaming the results to the implant. The platform is able to cover a broad range of research applications; from noise reduction and mimicking of normal hearing, over complex (simultaneous) stimulation strategies, to psychophysics. The hardware setup consists of a personal computer, an interface board, and a speech processor. The software is both expandable and to a great extent reusable in other applications.
Fu, Pengcheng; Johnson, Scott M.; Carrigan, Charles R.
2011-01-01
Hydraulic fracturing is currently the primary method for stimulating low-permeability geothermal reservoirs and creating Enhanced (or Engineered) Geothermal Systems (EGS) with improved permeability and heat production efficiency. Complex natural fracture systems usually exist in the formations to be stimulated and it is therefore critical to understand the interactions between existing fractures and newly created fractures before optimal stimulation strategies can be developed. Our study aims to improve the understanding of EGS stimulation-response relationships by developing and applying computer-based models that can effectively reflect the key mechanisms governing interactions between complex existing fracture networks and newly created hydraulic fractures. In this paper, we first briefly describe the key modules of our methodology, namely a geomechanics solver, a discrete fracture flow solver, a rock joint response model, an adaptive remeshing module, and most importantly their effective coupling. After verifying the numerical model against classical closed-form solutions, we investigate responses of reservoirs with different preexisting natural fractures to a variety of stimulation strategies. The factors investigated include: the in situ stress states (orientation of the principal stresses and the degree of stress anisotropy), pumping pressure, and stimulation sequences of multiple wells.
A Wearable Multi-Site System for NMES-Based Hand Function Restoration.
Crema, Andrea; Malesevic, Nebojsa; Furfaro, Ivan; Raschella, Flavio; Pedrocchi, Alessandra; Micera, Silvestro
2018-02-01
Reaching and grasping impairments significantly affect the quality of life for people who have experienced a stroke or spinal cord injury. The long-term well-being of patients varies greatly according to the restorable residual capabilities. Electrical stimulation could be a promising solution to restore motor functions in these conditions, but its use is not clinically widespread. Here, we introduce the HandNMES, an electrode array (EA) for neuromuscular electrical stimulation (NMES) aimed at grasp training and assistance. The device was designed to deliver electrical stimulation to extrinsic and intrinsic hand muscles. Six independent EAs, positioned on the user forearm and hand, deliver NMES pulses originating from an external stimulator equipped with demultiplexers for interfacing with a large number of electrodes. The garment was designed to be adaptable to user needs and anthropometric characteristics; size, shape, and contact materials can be customized, and stimulation characteristics such as intensity of stimulation and virtual electrode location, and size can be adjusted. We performed extensive tests with nine healthy subjects showing the efficacy of the HandNMES in terms of stimulation performance and personalization. Because encouraging results were achieved, in the coming months, the HandNMES device will be tested in pilot clinical trials.
Compact biomedical pulsed signal generator for bone tissue stimulation
Kronberg, J.W.
1993-06-08
An apparatus for stimulating bone tissue for stimulating bone growth or treating osteoporosis by applying directly to the skin of the patient an alternating current electrical signal comprising wave forms known to simulate the piezoelectric constituents in bone. The apparatus may, by moving a switch, stimulate bone growth or treat osteoporosis, as desired. Based on low-power CMOS technology and enclosed in a moisture-resistant case shaped to fit comfortably, two astable multivibrators produce the desired waveforms. The amplitude, pulse width and pulse frequency, and the subpulse width and subpulse frequency of the waveforms are adjustable. The apparatus, preferably powered by a standard 9-volt battery, includes signal amplitude sensors and warning signals indicate an output is being produced and the battery needs to be replaced.
Optically stimulated luminescence in Cu+ doped lithium orthophosphate
NASA Astrophysics Data System (ADS)
Barve, R. A.; Patil, R. R.; Moharil, S. V.; Bhatt, B. C.; Kulkarni, M. S.
2015-02-01
Optically stimulated luminescence (OSL) in Cu+ doped Li3PO4 synthesized by co-precipitation technique using different phosphorus precursors was studied. Changes in the luminescent properties were observed with change in the phosphorus precursors. All the synthesized phosphors showed intense fading but the OSL sensitivity was comparable to that of the commercially available Al2O3:C (Landauer Inc.). In general, BSL (blue stimulated luminescence) decay was very fast but the GSL (green stimulated luminescence) decay was comparable to that of Al2O3:C phosphor. Phosphors with fast decay, good sensitivity and intense fading are suitable for real-time dosimetry. Therefore, Cu-doped Li3PO4 could be developed for real-time dosimetry using a fiber optic based OSL reader system.
[Arm rehabilitation : Current concepts and therapeutic options].
Platz, T; Schmuck, L
2016-10-01
Arm paralysis after a stroke is a major cause of impairment. Presentation of therapeutic options and the efficacy in arm rehabilitation after stroke. Based on a systematic critical appraisal of randomized controlled trials (RCT) the therapeutic procedures for arm paralysis after stroke in the context of their effectiveness are introduced, including robotic therapy, mirror therapy, constraint-induced movement therapy (CIMT), arm basis training, arm ability training, neuromuscular electrical stimulation, bilateral and task-specific training, mental training and transcranial stimulation techniques, such as repetitive transcranial magnetic stimulation (rTMS) and transcranial direct current stimulation (tDCS). Several therapeutic procedures with proven efficacy are currently available for arm rehabilitation after stroke. Their differential indications are presented and associated with conclusions for clinical practice.
Stress inoculation training supported by physiology-driven adaptive virtual reality stimulation.
Popović, Sinisa; Horvat, Marko; Kukolja, Davor; Dropuljić, Branimir; Cosić, Kresimir
2009-01-01
Significant proportion of psychological problems related to combat stress in recent large peacekeeping operations underscores importance of effective methods for strengthening the stress resistance of military personnel. Adaptive control of virtual reality (VR) stimulation, based on estimation of the subject's emotional state from physiological signals, may enhance existing stress inoculation training (SIT). Physiology-driven adaptive VR stimulation can tailor the progress of stressful stimuli delivery to the physiological characteristics of each individual, which is indicated for improvement in stress resistance. Therefore, following an overview of SIT and its applications in the military setting, generic concept of physiology-driven adaptive VR stimulation is presented in the paper. Toward the end of the paper, closed-loop adaptive control strategy applicable to SIT is outlined.
Cosić, Kresimir; Popović, Sinisa; Kukolja, Davor; Horvat, Marko; Dropuljić, Branimir
2010-02-01
The significant proportion of severe psychological problems related to intensive stress in recent large peacekeeping operations underscores the importance of effective methods for strengthening the prevention and treatment of stress-related disorders. Adaptive control of virtual reality (VR) stimulation presented in this work, based on estimation of the person's emotional state from physiological signals, may enhance existing stress inoculation training (SIT). Physiology-driven adaptive VR stimulation can tailor the progress of stressful stimuli delivery to the physiological characteristics of each individual, which is indicated for improvement in stress resistance. Following an overview of physiology-driven adaptive VR stimulation, its major functional subsystems are described in more detail. A specific algorithm of stimuli delivery applicable to SIT is outlined.
Fujiyuki, T; Hamamoto, H; Ishii, K; Urai, M; Kataoka, K; Takeda, T; Shibata, S; Sekimizu, K
2012-04-01
In silkworm larvae, the mature form of paralytic peptide (PP), an insect cytokine, is produced from pro-PP in association with activation of innate immune responses, resulting in slow muscle contraction. We utilized this reaction, muscle contraction in silkworms coupled with innate immunity stimulation, to quantitatively measure the innate immune stimulating activity of various natural polysaccharides. β-Glucan of Gyrophora esculenta (GE-3), fucoidan from sporophyll of Undaria pinnatifida, and curldan induced silkworm muscle contraction. We further demonstrated that GE-3 had therapeutic effects on silkworms infected by baculovirus. Based on these findings, we propose that the silkworm muscle contraction assay is useful for screening substances that stimulate innate immunity before evaluating therapeutic effectiveness in mammals.
Compact biomedical pulsed signal generator for bone tissue stimulation
Kronberg, James W.
1993-01-01
An apparatus for stimulating bone tissue for stimulating bone growth or treating osteoporosis by applying directly to the skin of the patient an alternating current electrical signal comprising wave forms known to simulate the piezoelectric constituents in bone. The apparatus may, by moving a switch, stimulate bone growth or treat osteoporosis, as desired. Based on low-power CMOS technology and enclosed in a moisture-resistant case shaped to fit comfortably, two astable multivibrators produce the desired waveforms. The amplitude, pulse width and pulse frequency, and the subpulse width and subpulse frequency of the waveforms are adjustable. The apparatus, preferably powered by a standard 9-volt battery, includes signal amplitude sensors and warning signals indicate an output is being produced and the battery needs to be replaced.
2013-01-01
Background Reflexology is an alternative medical practice that produces beneficial effects by applying pressure to specific reflex areas. Our previous study suggested that reflexological stimulation induced cortical activation in somatosensory cortex corresponding to the stimulated reflex area; however, we could not rule out the possibility of a placebo effect resulting from instructions given during the experimental task. We used functional magnetic resonance imaging (fMRI) to investigate how reflexological stimulation of the reflex area is processed in the primary somatosensory cortex when correct and pseudo-information about the reflex area is provided. Furthermore, the laterality of activation to the reflexological stimulation was investigated. Methods Thirty-two healthy Japanese volunteers participated. The experiment followed a double-blind design. Half of the subjects received correct information, that the base of the second toe was the eye reflex area, and pseudo-information, that the base of the third toe was the shoulder reflex area. The other half of the subjects received the opposite information. fMRI time series data were acquired during reflexological stimulation to both feet. The experimenter stimulated each reflex area in accordance with an auditory cue. The fMRI data were analyzed using a conventional two-stage approach. The hemodynamic responses produced by the stimulation of each reflex area were assessed using a general linear model on an intra-subject basis, and a two-way repeated-measures analysis of variance was performed on an intersubject basis to determine the effect of reflex area laterality and information accuracy. Results Our results indicated that stimulation of the eye reflex area in either foot induced activity in the left middle postcentral gyrus, the area to which tactile sensation to the face projects, as well as in the postcentral gyrus contralateral foot representation area. This activity was not affected by pseudo information. The results also indicate that the relationship between the reflex area and the projection to the primary somatosensory cortex has a lateral pattern that differs from that of the actual somatotopical representation of the body. Conclusion These findings suggest that a robust relationship exists between neural processing of somatosensory percepts for reflexological stimulation and the tactile sensation of a specific reflex area. PMID:23711332
NASA Astrophysics Data System (ADS)
Ivorra, Antoni; Becerra-Fajardo, Laura; Castellví, Quim
2015-12-01
Objective. It is possible to develop implantable microstimulators whose actuation principle is based on rectification of high-frequency (HF) current bursts supplied through skin electrodes. This has been demonstrated previously by means of devices consisting of a single diode. However, previous single diode devices caused dc currents which made them impractical for clinical applications. Here flexible thread-like stimulation implants which perform charge balance are demonstrated in vivo. Approach. The implants weigh 40.5 mg and they consist of a 3 cm long tubular silicone body with a diameter of 1 mm, two electrodes at opposite ends, and, within the central section of the body, an electronic circuit made up of a diode, two capacitors, and a resistor. In the present study, each implant was percutaneously introduced through a 14 G catheter into either the gastrocnemius muscle or the cranial tibial muscle of a rabbit hindlimb. Then stimulation was performed by delivering HF bursts (amplitude <60 V, frequency 1 MHz, burst repetition frequency from 10 Hz to 200 Hz, duration = 200 μs) through a pair of textile electrodes strapped around the hindlimb and either isometric plantarflexion or dorsiflexion forces were recorded. Stimulation was also assayed 1, 2 and 4 weeks after implantation. Main results. The implants produced bursts of rectified current whose mean value was of a few mA and were capable of causing local neuromuscular stimulation. The implants were well-tolerated during the 4 weeks. Significance. Existing power supply methods, and, in particular inductive links, comprise stiff and bulky parts. This hinders the development of minimally invasive implantable devices for neuroprostheses based on electrical stimulation. The proposed methodology is intended to relieving such bottleneck. In terms of mass, thinness, and flexibility, the demonstrated implants appear to be unprecedented among the intramuscular stimulation implants ever assayed in vertebrates.
Helmer, S M; Pischke, C R; Van Hal, G; Vriesacker, B; Dempsey, R C; Akvardar, Y; Guillen-Grima, F; Salonna, F; Stock, C; Zeeb, H
2016-11-01
Overestimations of non-prescribed stimulant use of peers are well documented in the USA and have also been identified as predictive of personal stimulant consumption. This study aimed to examine whether overestimations of peer use and approval of the use are associated with personal use and attitude towards the use of non-prescribed stimulants among European university students. The EU funded 'Social Norms Intervention for the prevention of Polydrug usE (SNIPE)' study was conducted in seven European countries. In a web-based questionnaire, 4482 students were asked about their personal use and their attitude towards non-prescribed stimulant use, as well as the perceived peer use and peer attitude. 59% of students thought that the majority of their peers used non-prescribed stimulants more frequently than themselves, and only 4% thought that the use of the majority was lower than their personal use. The perception that the majority of peers had used non-prescribed stimulants at least once was significantly associated with higher odds for personal use of non-prescribed stimulants (OR: 3.30, 95% CI: 2.32-4.71). In addition, the perception that the majority of peers approved of the non-prescribed use of stimulants was associated with a 4.03 (95% CI: 3.35-4.84) times higher likelihood for personal approval. European university students generally perceived the non-prescribed use of stimulants of peers to be higher than their personal use. This perception, as well as a perception of higher approval in the peer group, was associated with a higher likelihood of personal non-prescribed stimulant medication use and approval. Copyright © 2016. Published by Elsevier Ireland Ltd.
Watanabe, Kosuke; Kudo, Yosuke; Sugawara, Eriko; Nakamizo, Tomoki; Amari, Kazumitsu; Takahashi, Koji; Tanaka, Osamu; Endo, Miho; Hayakawa, Yuko; Johkura, Ken
2018-01-15
Repetitive transcranial magnetic stimulation (rTMS) is reported to improve chronic post-stoke hemiparesis. However, application of rTMS during the acute phase of post-stroke has not fully been investigated. We investigated the safety and the efficacy of intermittent theta-burst stimulation (iTBS) of the affected motor cortex and 1-Hz stimulation of the unaffected hemisphere during the acute phase in patients with hemiparesis due to capsular infarction. Twenty one patients who met the study criteria were randomly assigned to receive, starting within 7days after stroke onset and for a period of 10days, iTBS of the affected motor cortex hand area (n=8), 1-Hz stimulation of the unaffected motor cortex hand area (n=7), or sham stimulation (n=6). Upper limb motor function was evaluated before rTMS and 12weeks after onset of the stroke. Evaluation was based on the Fugl-Meyer Assessment (FMA), Stroke Impairment Assessment Set (SIAS), Modified Ashworth Scale (MAS), grip strength, and motor evoked potential (MEP) amplitude in the first dorsal interosseous (FDI) muscle. Both iTBS applied to the affected motor cortex hand area and 1-Hz stimulation applied to the unaffected motor cortex hand area enhanced motor recovery. In comparison to sham stimulation, iTBS increased the SIAS finger-function test score, and 1-Hz stimulation decreased the MAS wrist and finger score. Ipsilesional iTBS and contralesional 1-Hz stimulation applied during the acute phase of stroke have different effects: ipsilesional iTBS improves movement of the affected limb, whereas contralesional 1-Hz stimulation reduces spasticity of the affected limb. Copyright © 2017 Elsevier B.V. All rights reserved.
Vagus nerve stimulation magnet activation for seizures: a critical review.
Fisher, R S; Eggleston, K S; Wright, C W
2015-01-01
Some patients receiving VNS Therapy report benefit from manually activating the generator with a handheld magnet at the time of a seizure. A review of 20 studies comprising 859 subjects identified patients who reported on-demand magnet mode stimulation to be beneficial. Benefit was reported in a weighted average of 45% of patients (range 0-89%) using the magnet, with seizure cessation claimed in a weighted average of 28% (range 15-67%). In addition to seizure termination, patients sometimes reported decreased intensity or duration of seizures or the post-ictal period. One study reported an isolated instance of worsening with magnet stimulation (Arch Pediatr Adolesc Med, 157, 2003 and 560). All of the reviewed studies assessed adjunctive magnet use. No studies were designed to provide Level I evidence of efficacy of magnet-induced stimulation. Retrospective analysis of one pivotal randomized trial of VNS therapy showed significantly more seizures terminated or improved in the active stimulation group vs the control group. Prospective, controlled studies would be required to isolate the effect and benefit of magnet mode stimulation and to document that the magnet-induced stimulation is the proximate cause of seizure reduction. Manual application of the magnet to initiate stimulation is not always practical because many patients are immobilized or unaware of their seizures, asleep or not in reach of the magnet. Algorithms based on changes in heart rate at or near the onset of the seizure provide a methodology for automated responsive stimulation. Because literature indicates additional benefits from on-demand magnet mode stimulation, a potential role exists for automatic activation of stimulation. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
De Oliveira, Thaís Cristina Galdino; Soares, Fernanda Cabral; De Macedo, Liliane Dias E Dias; Diniz, Domingos Luiz Wanderley Picanço; Bento-Torres, Natáli Valim Oliver; Picanço-Diniz, Cristovam Wanderley
2014-01-01
The aim of the present report was to evaluate the effectiveness and impact of multisensory and cognitive stimulation on improving cognition in elderly persons living in long-term-care institutions (institutionalized [I]) or in communities with their families (noninstitutionalized [NI]). We compared neuropsychological performance using language and Mini-Mental State Examination (MMSE) test scores before and after 24 and 48 stimulation sessions. The two groups were matched by age and years of schooling. Small groups of ten or fewer volunteers underwent the stimulation program, twice a week, over 6 months (48 sessions in total). Sessions were based on language and memory exercises, as well as visual, olfactory, auditory, and ludic stimulation, including music, singing, and dance. Both groups were assessed at the beginning (before stimulation), in the middle (after 24 sessions), and at the end (after 48 sessions) of the stimulation program. Although the NI group showed higher performance in all tasks in all time windows compared with I subjects, both groups improved their performance after stimulation. In addition, the improvement was significantly higher in the I group than the NI group. Language tests seem to be more efficient than the MMSE to detect early changes in cognitive status. The results suggest the impoverished environment of long-term-care institutions may contribute to lower cognitive scores before stimulation and the higher improvement rate of this group after stimulation. In conclusion, language tests should be routinely adopted in the neuropsychological assessment of elderly subjects, and long-term-care institutions need to include regular sensorimotor, social, and cognitive stimulation as a public health policy for elderly persons. PMID:24600211
Lan, Lihuan; Zhang, Xiaoni; Li, Xiangpen; Rong, Xiaoming; Peng, Ying
2017-08-22
As a non-invasive therapy, whether transcranial magnetic stimulation (TMS) is effective on migraine. This article was aimed to assess the efficacy of TMS on migraine based on randomized controlled trails (RCTs). We searched PubMed, Embase and Cochrane Library electronic databases for published studies which compared TMS group with sham group, conducted a meta-analysis of all RCTs. Five studies, consisting of 313 migraine patients, were identified. Single-pulse transcranial magnetic stimulation is effective for the acute treatment of migraine with aura after the first attack (p = 0.02). And, the efficacy of TMS on chronic migraine was not significant (OR 2.93; 95% CI 0.71-12.15; p = 0.14). TMS is effective for migraine based on the studies included in the article.
NASA Astrophysics Data System (ADS)
Sedwick, P. N.; Bernhardt, P. W.; Mulholland, M. R.; Najjar, R. G.; Blumen, L. M.; Sohst, B. M.; Sookhdeo, C.; Widner, B.
2018-04-01
To assess phytoplankton nutritional status in seasonally oligotrophic waters of the southern Mid-Atlantic Bight, and the potential for rain to stimulate primary production in this region during summer, shipboard bioassay experiments were performed using natural seawater and phytoplankton collected north and south of the Gulf Stream. Bioassay treatments comprised iron, nitrate, iron + nitrate, iron + nitrate + phosphate, and rainwater. Phytoplankton growth was inferred from changes in chlorophyll a, inorganic nitrogen, and carbon-13 uptake, relative to unamended control treatments. Results indicated the greatest growth stimulation by iron + nitrate + phosphate, intermediate growth stimulation by rainwater, modest growth stimulation by nitrate and iron + nitrate, and no growth stimulation by iron. Based on these data and analysis of seawater and atmospheric samples, nitrogen was the proximate limiting nutrient, with a secondary limitation imposed by phosphorus. Our results imply that summer rain events increase new production in these waters by contributing nitrogen and phosphorus, with the availability of the latter setting the upper limit on rain-stimulated new production.
Pashut, Tamar; Magidov, Dafna; Ben-Porat, Hana; Wolfus, Shuki; Friedman, Alex; Perel, Eli; Lavidor, Michal; Bar-Gad, Izhar; Yeshurun, Yosef; Korngreen, Alon
2014-01-01
Although transcranial magnetic stimulation (TMS) is a popular tool for both basic research and clinical applications, its actions on nerve cells are only partially understood. We have previously predicted, using compartmental modeling, that magnetic stimulation of central nervous system neurons depolarized the soma followed by initiation of an action potential in the initial segment of the axon. The simulations also predict that neurons with low current threshold are more susceptible to magnetic stimulation. Here we tested these theoretical predictions by combining in vitro patch-clamp recordings from rat brain slices with magnetic stimulation and compartmental modeling. In agreement with the modeling, our recordings demonstrate the dependence of magnetic stimulation-triggered action potentials on the type and state of the neuron and its orientation within the magnetic field. Our results suggest that the observed effects of TMS are deeply rooted in the biophysical properties of single neurons in the central nervous system and provide a framework both for interpreting existing TMS data and developing new simulation-based tools and therapies. PMID:24917788
NASA Astrophysics Data System (ADS)
Datta, Abhishek; Zhou, Xiang; Su, Yuzhou; Parra, Lucas C.; Bikson, Marom
2013-06-01
Objective. During transcranial electrical stimulation, current passage across the scalp generates voltage across the scalp surface. The goal was to characterize these scalp voltages for the purpose of validating subject-specific finite element method (FEM) models of current flow. Approach. Using a recording electrode array, we mapped skin voltages resulting from low-intensity transcranial electrical stimulation. These voltage recordings were used to compare the predictions obtained from the high-resolution model based on the subject undergoing transcranial stimulation. Main results. Each of the four stimulation electrode configurations tested resulted in a distinct distribution of scalp voltages; these spatial maps were linear with applied current amplitude (0.1 to 1 mA) over low frequencies (1 to 10 Hz). The FEM model accurately predicted the distinct voltage distributions and correlated the induced scalp voltages with current flow through cortex. Significance. Our results provide the first direct model validation for these subject-specific modeling approaches. In addition, the monitoring of scalp voltages may be used to verify electrode placement to increase transcranial electrical stimulation safety and reproducibility.
Non-invasive brain stimulation in neurorehabilitation: local and distant effects for motor recovery
Liew, Sook-Lei; Santarnecchi, Emilliano; Buch, Ethan R.; Cohen, Leonardo G.
2014-01-01
Non-invasive brain stimulation (NIBS) may enhance motor recovery after neurological injury through the causal induction of plasticity processes. Neurological injury, such as stroke, often results in serious long-term physical disabilities, and despite intensive therapy, a large majority of brain injury survivors fail to regain full motor function. Emerging research suggests that NIBS techniques, such as transcranial magnetic (TMS) and direct current (tDCS) stimulation, in association with customarily used neurorehabilitative treatments, may enhance motor recovery. This paper provides a general review on TMS and tDCS paradigms, the mechanisms by which they operate and the stimulation techniques used in neurorehabilitation, specifically stroke. TMS and tDCS influence regional neural activity underlying the stimulation location and also distant interconnected network activity throughout the brain. We discuss recent studies that document NIBS effects on global brain activity measured with various neuroimaging techniques, which help to characterize better strategies for more accurate NIBS stimulation. These rapidly growing areas of inquiry may hold potential for improving the effectiveness of NIBS-based interventions for clinical rehabilitation. PMID:25018714
Ueno, Shoogo
2017-01-01
Stimulation of deeper brain structures by transcranial magnetic stimulation (TMS) plays a role in the study of reward and motivation mechanisms, which may be beneficial in the treatment of several neurological and psychiatric disorders. However, electric field distributions induced in the brain by deep transcranial magnetic stimulation (dTMS) are still unknown. In this paper, the double cone coil, H-coil and Halo-circular assembly (HCA) coil which have been proposed for dTMS have been numerically designed. The distributions of magnetic flux density, induced electric field in an anatomically based realistic head model by applying the dTMS coils were numerically calculated by the impedance method. Results were compared with that of standard figure-of-eight (Fo8) coil. Simulation results show that double cone, H- and HCA coils have significantly deep field penetration compared to the conventional Fo8 coil, at the expense of induced higher and wider spread electrical fields in superficial cortical regions. Double cone and HCA coils have better ability to stimulate deep brain subregions compared to that of the H-coil. In the mean time, both double cone and HCA coils increase risk for optical nerve excitation. Our results suggest although the dTMS coils offer new tool with potential for both research and clinical applications for psychiatric and neurological disorders associated with dysfunctions of deep brain regions, the selection of the most suitable coil settings for a specific clinical application should be based on a balanced evaluation between stimulation depth and focality. PMID:28586349
Tolerance to extended galvanic vestibular stimulation: optimal exposure for astronaut training.
Dilda, Valentina; MacDougall, Hamish G; Moore, Steven T
2011-08-01
We have developed an analogue of postflight sensorimotor dysfunction in astronauts using pseudorandom galvanic vestibular stimulation (GVS). To date there has been no study of the effects of extended GVS on human subjects and our aim was to determine optimal exposure for astronaut training based on tolerance to intermittent and continuous galvanic stimulation. There were 60 subjects who were exposed to a total of 10.5 min of intermittent GVS at a peak current of 3.5 mA or 5 mA. A subset of 24 subjects who tolerated the intermittent stimulus were subsequently exposed to 20-min continuous stimulation at 3.5 mA or 5 mA. During intermittent GVS the large majority of subjects (78.3%) reported no or at most mild motion sickness symptoms, 13.3% reported moderate symptoms, and 8.3% experienced severe nausea and requested termination of the stimulus. During 20-min continuous exposure, 83.3% of subjects reported no or at most mild motion sickness symptoms and 16.7% (all in the 5-mA group) experienced severe nausea. Based on these results, we propose two basic modes of GVS application to minimize the incidence of motion sickness: intermittent high (5 mA) amplitude, suited to simulation of intensive operator tasks requiring a high-fidelity analogue of postflight sensorimotor dysfunction such as landing or docking maneuvers; and continuous low (3.5 mA) amplitude stimulation, for longer simulation scenarios such as extra vehicular activity. Our results suggest that neither mode of stimulation would induce motion sickness in the large majority of subjects for up to 20 min exposure.
Mandija, Stefano; Petrov, Petar I; Neggers, Sebastian F W; Luijten, Peter R; van den Berg, Cornelis A T
2016-11-01
Transcranial magnetic stimulation (TMS) is an emerging technique that allows non-invasive neurostimulation. However, the correct validation of electromagnetic models of typical TMS coils and the correct assessment of the incident TMS field (B TMS ) produced by standard TMS stimulators are still lacking. Such a validation can be performed by mapping B TMS produced by a realistic TMS setup. In this study, we show that MRI can provide precise quantification of the magnetic field produced by a realistic TMS coil and a clinically used TMS stimulator in the region in which neurostimulation occurs. Measurements of the phase accumulation created by TMS pulses applied during a tailored MR sequence were performed in a phantom. Dedicated hardware was developed to synchronize a typical, clinically used, TMS setup with a 3-T MR scanner. For comparison purposes, electromagnetic simulations of B TMS were performed. MR-based measurements allow the mapping and quantification of B TMS starting 2.5 cm from the TMS coil. For closer regions, the intra-voxel dephasing induced by B TMS prohibits TMS field measurements. For 1% TMS output, the maximum measured value was ~0.1 mT. Simulations reflect quantitatively the experimental data. These measurements can be used to validate electromagnetic models of TMS coils, to guide TMS coil positioning, and for dosimetry and quality assessment of concurrent TMS-MRI studies without the need for crude methods, such as motor threshold, for stimulation dose determination. Copyright © 2016 John Wiley & Sons, Ltd.
Stimulation of functional vision in children with perinatal brain damage.
Alimović, Sonja; Mejaski-Bosnjak, Vlatka
2011-01-01
Cerebral visual impairment (CVI) is one of the most common causes of bilateral visual loss, which frequently occurs due to perinatal brain injury. Vision in early life has great impact on acquisition of basic comprehensions which are fundamental for further development. Therefore, early detection of visual problems and early intervention is necessary. The aim of the present study is to determine specific visual functioning of children with perinatal brain damage and the influence of visual stimulation on development of functional vision at early age of life. We initially assessed 30 children with perinatal brain damage up to 3 years of age, who were reffered to our pediatric low vision cabinet in "Little house" from child neurologists, ophthalmologists Type and degree of visual impairment was determined according to functional vision assessment of each child. On the bases of those assessments different kind of visual stimulations were carried out with children who have been identified to have a certain visual impairment. Through visual stimulation program some of the children were stimulated with light stimulus, some with different materials under the ultraviolet (UV) light, and some with bright color and high contrast materials. Children were also involved in program of early stimulation of overall sensory motor development. Goals and methods of therapy were determined individually, based on observation of child's possibilities and need. After one year of program, reassessment was done. Results for visual functions and functional vision were compared to evaluate the improvement of the vision development. These results have shown that there was significant improvement in functional vision, especially in visual attention and visual communication.
Alternative right ventricular pacing sites.
Łuciuk, Dariusz; Łuciuk, Marek; Gajek, Jacek
2015-01-01
The main adverse effect of chronic stimulation is stimulation-induced heart failure in case of ventricular contraction dyssynchrony. Because of this fact, new techniques of stimulation should be considered to optimize electrotherapy. One of these methods is pacing from alternative right ventricular sites. The purpose of this article is to review currently accumulated data about alternative sites of cardiac pacing. Medline and PubMed bases were used to search English and Polish reports published recently. Recent studies report a deleterious effect of long term apical pacing. It is suggested that permanent apical stimulation, by omitting physiological conduction pattern with His-Purkinie network, may lead to electrical and mechanical dyssynchrony of heart muscle contraction. In the long term this pathological situation can lead to severe heart failure and death. Because of this, scientists began to search for some alternative sites of cardiac pacing to reduce the deleterious effect of stimulation. Based on current accumulated data, it is suggested that the right ventricular outflow tract, right ventricular septum, direct His-bundle or biventricular pacing are better alternatives due to more physiological electrical impulse propagation within the heart and the reduction of the dyssynchrony effect. These methods should preserve a better left ventricular function and prevent the development of heart failure in permanent paced patients. As there is still not enough, long-term, randomized, prospective, cross-over and multicenter studies, further research is required to validate the benefits of using this kind of therapy. The article should pay attention to new sites of cardiac stimulation as a better and safer method of treatment.
Basta, Dietmar; Götze, Romy; Gröschel, Moritz; Jansen, Sebastian; Janke, Oliver; Tzschentke, Barbara; Boyle, Patrick; Ernst, Arne
2015-12-01
In recent years, cochlear implants have been applied successfully for the treatment of unilateral hearing loss with quite surprising benefit. One reason for this successful treatment, including the relief from tinnitus, could be the normalization of spontaneous activity in the central auditory pathway because of the electrical stimulation. The present study, therefore, investigated at a cellular level, the effect of a unilateral chronic intracochlear stimulation on key structures of the central auditory pathway. Normal-hearing guinea pigs were mechanically single-sided deafened through a standard HiFocus1j electrode array (on a HiRes 90k cochlear implant) being inserted into the first turn of the cochlea. Four to five electrode contacts could be used for the stimulation. Six weeks after surgery, the speech processor (Auria) was fitted, based on tNRI values and mounted on the animal's back. The two experimental groups were stimulated 16 hours per day for 90 days, using a HiRes strategy based on different stimulation rates (low rate (275 pps/ch), high rate (5000 pps/ch)). The results were compared with those of unilateral deafened controls (implanted but not stimulated), as well as between the treatment groups. All animals experienced a standardized free field auditory environment. The low-rate group showed a significantly lower average spontaneous activity bilaterally in the dorsal cochlear nucleus and the medial geniculate body than the controls. However, there was no difference in the inferior colliculus and the primary auditory cortex. Spontaneous activity of the high-rate group was also reduced bilaterally in the dorsal cochlear nucleus and in the primary auditory cortex. No differences could be observed between the high-rate group and the controls in the contra-lateral inferior colliculus and medial geniculate body. The high-rate group showed bilaterally a higher activity in the CN and the MGB compared with the low-rate group, whereas in the IC and in the AC a trend for an opposite effect could be determined. Unilateral intracochlear electrical stimulation seems to facilitate the homeostasis of the network activity, since it decreases the spontaneous activity that is usually elevated upon deafferentiation. The electrical stimulation per se seems to be responsible for the bilateral changes described above, rather than the particular nature of the electrical stimulation (e.g., rate). The normalization effects of electrical stimulation found in the present study are of particular importance in cochlear implant recipients with single-sided deafness.
NASA Technical Reports Server (NTRS)
Goel, R.; Kofman, I.; DeDios, Y. E.; Jeevarajan, J.; Stepanyan, V.; Nair, M.; Congdon, S.; Fregia, M.; Cohen, H.; Bloomberg, J.J.;
2015-01-01
Sensorimotor changes such as postural and gait instabilities can affect the functional performance of astronauts when they transition across different gravity environments. We are developing a method, based on stochastic resonance (SR), to enhance information transfer by applying non-zero levels of external noise on the vestibular system (vestibular stochastic resonance, VSR). Our previous work has shown the advantageous effects of VSR in a balance task of standing on an unstable surface [1]. This technique to improve detection of vestibular signals uses a stimulus delivery system that provides imperceptibly low levels of white noise-based binaural bipolar electrical stimulation of the vestibular system. The goal of this project is to determine optimal levels of stimulation for SR applications by using a defined vestibular threshold of motion detection. A series of experiments were carried out to determine a robust paradigm to identify a vestibular threshold that can then be used to recommend optimal stimulation levels for sensorimotor adaptability (SA) training applications customized to each crewmember. The amplitude of stimulation to be used in the VSR application has varied across studies in the literature such as 60% of nociceptive stimulus thresholds [2]. We compared subjects' perceptual threshold with that obtained from two measures of body sway. Each test session was 463s long and consisted of several 15s long sinusoidal stimuli, at different current amplitudes (0-2 mA), interspersed with 20-20.5s periods of no stimulation. Subjects sat on a chair with their eyes closed and had to report their perception of motion through a joystick. A force plate underneath the chair recorded medio-lateral shear forces and roll moments. Comparison of threshold of motion detection obtained from joystick data versus body sway suggests that perceptual thresholds were significantly lower. In the balance task, subjects stood on an unstable surface and had to maintain balance, and the stimulation was administered from 20-400% of subjects' vestibular threshold. Optimal stimulation amplitude was determined at which the balance performance was best compared to control (no stimulation). Preliminary results show that, in general, using stimulation amplitudes at 40-60% of perceptual motion threshold significantly improved the balance performance. We hypothesize that VSR stimulation will act synergistically with SA training to improve adaptability by increasing utilization of vestibular information and therefore will help us to optimize and personalize a SA countermeasure prescription. This combination may help to significantly reduce the number of days required to recover functional performance to preflight levels after long-duration spaceflight.
Park, Sang-Hyug; Sim, Woo Young; Min, Byoung-Hyun; Yang, Sang Sik; Khademhosseini, Ali; Kaplan, David L
2012-01-01
Adipose tissue-derived stem cells (ASCs) are considered as an attractive stem cell source for tissue engineering and regenerative medicine. We compared human bone marrow-derived mesenchymal stem cells (hMSCs) and hASCs under dynamic hydraulic compression to evaluate and compare osteogenic abilities. A novel micro cell chip integrated with microvalves and microscale cell culture chambers separated from an air-pressure chamber was developed using microfabrication technology. The microscale chip enables the culture of two types of stem cells concurrently, where each is loaded into cell culture chambers and dynamic compressive stimulation is applied to the cells uniformly. Dynamic hydraulic compression (1 Hz, 1 psi) increased the production of osteogenic matrix components (bone sialoprotein, oateopontin, type I collagen) and integrin (CD11b and CD31) expression from both stem cell sources. Alkaline phosphatase and Alrizarin red staining were evident in the stimulated hMSCs, while the stimulated hASCs did not show significant increases in staining under the same stimulation conditions. Upon application of mechanical stimulus to the two types of stem cells, integrin (β1) and osteogenic gene markers were upregulated from both cell types. In conclusion, stimulated hMSCs and hASCs showed increased osteogenic gene expression compared to non-stimulated groups. The hMSCs were more sensitive to mechanical stimulation and more effective towards osteogenic differentiation than the hASCs under these modes of mechanical stimulation.
Eickenscheidt, Max; Zeck, Günther
2014-06-01
The initiation of an action potential by extracellular stimulation occurs after local depolarization of the neuronal membrane above threshold. Although the technique shows remarkable clinical success, the site of action and the relevant stimulation parameters are not completely understood. Here we identify the site of action potential initiation in rabbit retinal ganglion cells (RGCs) interfaced to an array of extracellular capacitive stimulation electrodes. We determine which feature of the extracellular potential governs action potential initiation by simultaneous stimulation and recording RGCs interfaced in epiretinal configuration. Stimulation electrodes were combined to areas of different size and were presented at different positions with respect to the RGC. Based on stimulation by electrodes beneath the RGC soma and simultaneous sub-millisecond latency measurement we infer axonal initiation at the site of maximal curvature of the extracellular potential. Stimulation by electrodes at different positions along the axon reveals a nearly constant threshold current density except for a narrow region close to the cell soma. These findings are explained by the concept of the activating function modified to consider a region of lower excitability close to the cell soma. We present a framework how to estimate the site of action potential initiation and the stimulus required to cross threshold in neurons tightly interfaced to capacitive stimulation electrodes. Our results underscore the necessity of rigorous electrical characterization of the stimulation electrodes and of the interfaced neural tissue.
Min, Byoung-Hyun; Yang, Sang Sik; Khademhosseini, Ali; Kaplan, David L.
2012-01-01
Adipose tissue-derived stem cells (ASCs) are considered as an attractive stem cell source for tissue engineering and regenerative medicine. We compared human bone marrow-derived mesenchymal stem cells (hMSCs) and hASCs under dynamic hydraulic compression to evaluate and compare osteogenic abilities. A novel micro cell chip integrated with microvalves and microscale cell culture chambers separated from an air-pressure chamber was developed using microfabrication technology. The microscale chip enables the culture of two types of stem cells concurrently, where each is loaded into cell culture chambers and dynamic compressive stimulation is applied to the cells uniformly. Dynamic hydraulic compression (1 Hz, 1 psi) increased the production of osteogenic matrix components (bone sialoprotein, oateopontin, type I collagen) and integrin (CD11b and CD31) expression from both stem cell sources. Alkaline phosphatase and Alrizarin red staining were evident in the stimulated hMSCs, while the stimulated hASCs did not show significant increases in staining under the same stimulation conditions. Upon application of mechanical stimulus to the two types of stem cells, integrin (β1) and osteogenic gene markers were upregulated from both cell types. In conclusion, stimulated hMSCs and hASCs showed increased osteogenic gene expression compared to non-stimulated groups. The hMSCs were more sensitive to mechanical stimulation and more effective towards osteogenic differentiation than the hASCs under these modes of mechanical stimulation. PMID:23029565
NASA Astrophysics Data System (ADS)
Kallweit, Nicole; Baumhoff, Peter; Krueger, Alexander; Tinne, Nadine; Heisterkamp, Alexander; Kral, Andrej; Maier, Hannes; Ripken, Tammo
2016-02-01
Optical cochlea stimulation is under investigation as a potential alternative to conventional electric cochlea implants in treatment of sensorineural hearing loss. If direct optical stimulation of spiral ganglion neurons (SGNs) would be feasible, a smaller stimulation volume and, therefore, an improved frequency resolution could be achieved. However, it is unclear whether the mechanism of optical stimulation is based on direct neuronal stimulation or on optoacoustics. Animal studies on hearing vs. deafened guinea pigs already identified the optoacoustic effect as potential mechanism for intra-cochlear optical stimulation. In order to characterize the optoacoustic stimulus more thoroughly the acoustic signal along the beam path of a pulsed laser in water was quantified and compared to the neuronal response properties of hearing guinea pigs stimulated with the same laser parameters. Two pulsed laser systems were used for analyzing the influence of variable pulse duration, pulse energy, pulse peak power and absorption coefficient. Preliminary results of the experiments in water and in vivo suggesta similar dependency of response signals on the applied laser parameters: Both datasets show an onset and offset signal at the beginning and the end of the laser pulse. Further, the resulting signal amplitude depends on the pulse peak power as well as the temporal development of the applied laser pulse. The data indicates the maximum of the first derivative of power as the decisive factor. In conclusion our findings strengthen the hypothesis of optoacoustics as the underlying mechanism for optical stimulation of the cochlea.
2011-01-01
Background Of 136 million babies born annually, around 10 million require assistance to breathe. Each year 814,000 neonatal deaths result from intrapartum-related events in term babies (previously “birth asphyxia”) and 1.03 million from complications of prematurity. No systematic assessment of mortality reduction from tactile stimulation or resuscitation has been published. Objective To estimate the mortality effect of immediate newborn assessment and stimulation, and basic resuscitation on neonatal deaths due to term intrapartum-related events or preterm birth, for facility and home births. Methods We conducted systematic reviews for studies reporting relevant mortality or morbidity outcomes. Evidence was assessed using GRADE criteria adapted to provide a systematic approach to mortality effect estimates for the Lives Saved Tool (LiST). Meta-analysis was performed if appropriate. For interventions with low quality evidence but strong recommendation for implementation, a Delphi panel was convened to estimate effect size. Results We identified 24 studies of neonatal resuscitation reporting mortality outcomes (20 observational, 2 quasi-experimental, 2 cluster randomized controlled trials), but none of immediate newborn assessment and stimulation alone. A meta-analysis of three facility-based studies examined the effect of resuscitation training on intrapartum-related neonatal deaths (RR= 0.70, 95%CI 0.59-0.84); this estimate was used for the effect of facility-based basic neonatal resuscitation (additional to stimulation). The evidence for preterm mortality effect was low quality and thus expert opinion was sought. In community-based studies, resuscitation training was part of packages with multiple concurrent interventions, and/or studies did not distinguish term intrapartum-related from preterm deaths, hence no meta-analysis was conducted. Our Delphi panel of 18 experts estimated that immediate newborn assessment and stimulation would reduce both intrapartum-related and preterm deaths by 10%, facility-based resuscitation would prevent a further 10% of preterm deaths, and community-based resuscitation would prevent further 20% of intrapartum-related and 5% of preterm deaths. Conclusion Neonatal resuscitation training in facilities reduces term intrapartum-related deaths by 30%. Yet, coverage of this intervention remains low in countries where most neonatal deaths occur and is a missed opportunity to save lives. Expert opinion supports smaller effects of neonatal resuscitation on preterm mortality in facilities and of basic resuscitation and newborn assessment and stimulation at community level. Further evaluation is required for impact, cost and implementation strategies in various contexts. Funding This work was supported by the Bill & Melinda Gates Foundation through a grant to the US Fund for UNICEF, and to the Saving Newborn Lives program of Save the Children, through Save the Children US. PMID:21501429
ERIC Educational Resources Information Center
Bruckmann, Sarah; Hauk, Daniela; Roessner, Veit; Resch, Franz; Freitag, Christine M.; Kammer, Thomas; Ziemann, Ulf; Rothenberger, Aribert; Weisbrod, Matthias; Bender, Stephan
2012-01-01
Attention deficit hyperactivity disorder is one of the most frequent neuropsychiatric disorders in childhood. Transcranial magnetic stimulation studies based on muscle responses (motor-evoked potentials) suggested that reduced motor inhibition contributes to hyperactivity, a core symptom of the disease. Here we employed the N100 component of the…
The Actifier: A Device for Neurophysiological Studies of Orofacial Control in Human Infants.
ERIC Educational Resources Information Center
Finan, Donald S.; Barlow, Steven M.
1996-01-01
This study examined responsiveness of the suck central pattern generator to external stimulation, based on premise that early control of sucking and smiling sets stage for more differentiated use of orofacial muscle system for speech. A device for the stimulation of intraoral tissues in neonates, called the actifier, features a wide frequency…
ERIC Educational Resources Information Center
Borgschatz, Heidi; Frankenberger, William; Eder, Rhonda
1999-01-01
Two groups of college students were given different types information to read regarding stimulant medicines for attention deficit hyperactive disorder. No differences were found between the gender of participants and their perceptions of the medications based on reading materials. Type of information did influence their views of the efficacy and…
[Mechanisms and applications of transcutaneous electrical nerve stimulation in analgesia].
Tang, Zheng-Yu; Wang, Hui-Quan; Xia, Xiao-Lei; Tang, Yi; Peng, Wei-Wei; Hu, Li
2017-06-25
Transcutaneous electrical nerve stimulation (TENS), as a non-pharmacological and non-invasive analgesic therapy with low-cost, has been widely used to relieve pain in various clinical applications, by delivering current pulses to the skin area to activate the peripheral nerve fibers. Nevertheless, analgesia induced by TENS varied in the clinical practice, which could be caused by the fact that TENS with different stimulus parameters has different biological mechanisms in relieving pain. Therefore, to advance our understanding of TENS in various basic and clinical studies, we discussed (1) neurophysiological and biochemical mechanisms of TENS-induced analgesia; (2) relevant factors that may influence analgesic effects of TENS from the perspectives of stimulus parameters, including stimulated position, pulse parameters (current intensity, frequency, and pulse width), stimulus duration and used times in each day; and (3) applications of TENS in relieving clinical pain, including post-operative pain, chronic low back pain and labor pain. Finally, we propose that TENS may involve multiple and complex psychological neurophysiological mechanisms, and suggest that different analgesic effects of TENS with different stimulus parameters should be taken into consideration in clinical applications. In addition, to optimize analgesic effect, we recommend that individual-based TENS stimulation parameters should be designed by considering individual differences among patients, e.g., adaptively adjusting the stimulation parameters based on the dynamic ratings of patients' pain.
Dragas, Jelena; Viswam, Vijay; Shadmani, Amir; Chen, Yihui; Bounik, Raziyeh; Stettler, Alexander; Radivojevic, Milos; Geissler, Sydney; Obien, Marie; Müller, Jan; Hierlemann, Andreas
2017-06-01
Biological cells are characterized by highly complex phenomena and processes that are, to a great extent, interdependent. To gain detailed insights, devices designed to study cellular phenomena need to enable tracking and manipulation of multiple cell parameters in parallel; they have to provide high signal quality and high spatiotemporal resolution. To this end, we have developed a CMOS-based microelectrode array system that integrates six measurement and stimulation functions, the largest number to date. Moreover, the system features the largest active electrode array area to date (4.48×2.43 mm 2 ) to accommodate 59,760 electrodes, while its power consumption, noise characteristics, and spatial resolution (13.5 μm electrode pitch) are comparable to the best state-of-the-art devices. The system includes: 2,048 action-potential (AP, bandwidth: 300 Hz to 10 kHz) recording units, 32 local-field-potential (LFP, bandwidth: 1 Hz to 300 Hz) recording units, 32 current recording units, 32 impedance measurement units, and 28 neurotransmitter detection units, in addition to the 16 dual-mode voltage-only or current/voltage-controlled stimulation units. The electrode array architecture is based on a switch matrix, which allows for connecting any measurement/stimulation unit to any electrode in the array and for performing different measurement/stimulation functions in parallel.
[Design of an embedded stroke rehabilitation apparatus system based on Linux computer engineering].
Zhuang, Pengfei; Tian, XueLong; Zhu, Lin
2014-04-01
A realizaton project of electrical stimulator aimed at motor dysfunction of stroke is proposed in this paper. Based on neurophysiological biofeedback, this system, using an ARM9 S3C2440 as the core processor, integrates collection and display of surface electromyography (sEMG) signal, as well as neuromuscular electrical stimulation (NMES) into one system. By embedding Linux system, the project is able to use Qt/Embedded as a graphical interface design tool to accomplish the design of stroke rehabilitation apparatus. Experiments showed that this system worked well.
My, T-H; Robin, O; Mhibik, O; Drag, C; Bretenaker, F
2009-03-30
The evolution of the spectrum of a singly resonant optical parametric oscillator based on an MgO-doped periodically poled stoichiometric lithium tantalate crystal is observed when the pump power is varied. The onset of cascade Raman lasing due to stimulated Raman scattering in the nonlinear crystal is analyzed. Spurious frequency doubling and sum-frequency generation phenomena are observed and understood. A strong reduction of the intracavity Raman scattering is obtained by a careful adjustment of the cavity losses.