Yamamoto, Michiro; Malay, Sunitha; Fujihara, Yuki; Zhong, Lin; Chung, Kevin C.
2016-01-01
Background Outcomes after implant arthroplasty for primary degenerative and posttraumatic osteoarthritis (OA) of proximal interphalangeal (PIP) joint were different according to the implant design and surgical approach. The purpose of this systematic review was to evaluate outcomes of various types of implant arthroplasty for PIP joint OA with emphasis on different surgical approaches. Methods The authors searched all available literature in the PubMed and EMBASE databases for articles reporting on outcomes of implant arthroplasty for PIP joint OA. Data collection included active arc of motion (AOM), extension lag, and complications. We combined the data of various types of surface replacement arthroplasty into one group to compare with silicone arthroplasty. Results A total of 849 articles were screened, yielding 40 studies for final review. The mean postoperative AOM and the mean gain in AOM of silicone implant with volar approach were 58° and 17° respectively which was greater than surface replacement implant with dorsal approach as 51° and 8°, respectively. The mean postoperative extension lag of silicone implant with volar approach and surface replacement with dorsal approach was 5° and 14° respectively. The revision rate of silicone implant with volar approach and surface replacement with dorsal approach was 6% and 18% at the mean follow-up period of 41.2 and 51 months, respectively. Conclusions Silicone implant with volar approach showed the best AOM with less extension lag and fewer complications after surgery among all the implant designs and surgical approaches. PMID:28445369
Yamamoto, Michiro; Malay, Sunitha; Fujihara, Yuki; Zhong, Lin; Chung, Kevin C
2017-05-01
Outcomes after implant arthroplasty for primary degenerative and posttraumatic osteoarthritis of the proximal interphalangeal joint were different according to the implant design and surgical approach. The purpose of this systematic review was to evaluate outcomes of various types of implant arthroplasty for proximal interphalangeal joint osteoarthritis, with an emphasis on different surgical approaches. The authors searched all available literature in the PubMed and EMBASE databases for articles reporting on outcomes of implant arthroplasty for proximal interphalangeal joint osteoarthritis. Data collection included active arc of motion, extension lag, and complications. The authors combined the data of various types of surface replacement arthroplasty into one group for comparison with silicone arthroplasty. A total of 849 articles were screened, yielding 40 studies for final review. The mean postoperative arc of motion and the mean gain in arc of motion of silicone implant with the volar approach were 58 and 17 degrees, respectively, which was greater than surface replacement implant with the dorsal approach at 51 and 8 degrees, respectively. The mean postoperative extension lag of silicone implant with the volar approach and surface replacement with the dorsal approach was 5 and 14 degrees, respectively. The revision rate of silicone implant with the volar approach and surface replacement with the dorsal approach was 6 percent and 18 percent at a mean follow-up of 41.2 and 51 months, respectively. Silicone implant with the volar approach showed the best arc of motion, with less extension lag and fewer complications after surgery among all the implant designs and surgical approaches.
Shoulder replacement - discharge
Total shoulder arthroplasty - discharge; Endoprosthetic shoulder replacement - discharge; Partial shoulder replacement - discharge; Partial shoulder arthroplasty - discharge; Replacement - shoulder - discharge; Arthroplasty - shoulder - ...
[Modern tribology in total hip arthroplasty: pros and cons].
Gómez-García, F
2014-01-01
The wear products and adverse reactions that occur on bearing surfaces represent one of the greatest challenges in prosthetic replacements, as the latter experience increasing demands due to the large number of young and older adult patients that have a long life expectancy and remarkable activity. The purpose of this review is to analyze the pros and cons of the new advances in the bearing components of the articular surfaces of current total hip arthroplasties. We also discuss the strategies used historically, their problems, results and the surgeon's role in prescribing the tribologic couple that best fits each patient's needs. We conclude with practical recommendations for the prescription and management of the latest articular couples for total hip arthroplasty.
Lee, Ho Min; Kim, Jong Pil; Chung, Phil Hyun; Kang, Suk; Kim, Young Sung; Go, Bo Seong
2018-05-24
Knee dislocation following total knee replacement arthroplasty is a rare but serious complication. The incidence of dislocation following primary total knee arthroplasty with posterior stabilized implants ranges from 0.15 to 0.5%, and posterior dislocation after revision total knee arthroplasty is even rarer. Here, we report the case of a 76-year-old male who presented with posterior dislocation after posterior stabilized revision total knee arthroplasty.
Kurtz, Steven M; Ong, Kevin L; Lau, Edmund; Bozic, Kevin J
2014-04-16
Few studies have explored the role of the National Health Expenditure and macroeconomics on the utilization of total joint replacement. The economic downturn has raised questions about the sustainability of growth for total joint replacement in the future. Previous projections of total joint replacement demand in the United States were based on data up to 2003 using a statistical methodology that neglected macroeconomic factors, such as the National Health Expenditure. Data from the Nationwide Inpatient Sample (1993 to 2010) were used with United States Census and National Health Expenditure data to quantify historical trends in total joint replacement rates, including the two economic downturns in the 2000s. Primary and revision hip and knee arthroplasty were identified using codes from the International Classification of Diseases, Ninth Revision, Clinical Modification. Projections in total joint replacement were estimated using a regression model incorporating the growth in population and rate of arthroplasties from 1993 to 2010 as a function of age, sex, race, and census region using the National Health Expenditure as the independent variable. The regression model was used in conjunction with government projections of National Health Expenditure from 2011 to 2021 to estimate future arthroplasty rates in subpopulations of the United States and to derive national estimates. The growth trend for the incidence of joint arthroplasty, for the overall United States population as well as for the United States workforce, was insensitive to economic downturns. From 2009 to 2010, the total number of procedures increased by 6.0% for primary total hip arthroplasty, 6.1% for primary total knee arthroplasty, 10.8% for revision total hip arthroplasty, and 13.5% for revision total knee arthroplasty. The National Health Expenditure model projections for primary hip replacement in 2020 were higher than a previously projected model, whereas the current model estimates for total knee arthroplasty were lower. Economic downturns in the 2000s did not substantially influence the national growth trends for hip and knee arthroplasty in the United States. These latest updated projections provide a basis for surgeons, hospitals, payers, and policy makers to plan for the future demand for total joint replacement surgery.
Hip arthroplasty today and tomorrow.
Amstutz, H C
1987-12-01
Acrylic-fixed total hip and surface replacement arthroplasty have been very effective in affording immediate relief of pain and providing improved function. Complications have been reduced by improvements in design, materials, and especially technique. They are now very low in the elderly, and the stem type acrylic-fixed design remains the procedure of choice. The failure rates in youthful patients and those with bone-stock deficiencies have been high in both THR and surface types, although the latter had the advantage of preserving femoral stock. On the femoral side, the new "macro" femoral designs from Europe and "micro" femoral porous designs have shown promise, but thigh pain, incomplete and difficult to predict bone ingrowth patterns, coupled with removal problems have influenced design and technique changes. Both press-fit stem types and porous surface replacements have produced promising initial results with less potential downside risks. On the acetabular side, both the cementless hemispherical with screw-type adjuvant fixation, or the chamfered cylinder designs, used primarily with the UCLA porous surface replacements, but also with stem-type devices, appear to achieve best short-term results, while the entire variety of screw rings are disappointing. The future will bring further refinements in technique and specific indications for certain types of replacement stem in specific types of bone stock deficiencies. The all ceramic-ceramic and ceramic-polyethylene bearings show promise of reducing wear and, hence, should improve longevity of implant fixation.
Incidence and Location of Pain in Young, Active Patients Following Hip Arthroplasty.
Nam, Denis; Nunley, Ryan M; Sauber, Timothy J; Johnson, Staci R; Brooks, Peter J; Barrack, Robert L
2015-11-01
Persistent pain following hip arthroplasty remains a concern, especially in young, active patients. Four hundred twenty patients less than 60 years of age with a pre-symptomatic UCLA score ≥ 6 (196 total hip arthroplasty [THA]; 224 surface replacement arthroplasty [SRA]) completed a pain-drawing questionnaire investigating the location, severity, and frequency of pain around the hip. At a mean of 2.9 years of follow-up, 40% reported pain in at least one location around the hip. There was no difference in the incidence of groin pain between SRA and THA patients (32% vs. 29%, P=0.6), but THA patients had a greater incidence of anterior (25% vs. 8%, P<0.001) and lateral (20% vs. 10%, P=0.01) thigh pain. A high percentage of young, active patients experience persistent pain following hip arthroplasty. Copyright © 2015 Elsevier Inc. All rights reserved.
Cip, Johannes; von Strempel, Archibald; Bach, Christian; Luegmair, Matthias; Benesch, Thomas; Martin, Arno
2014-11-01
Taper junctions of large diameter metal-on-metal femoral heads and femoral stems were described as metal ion generator due to accelerated wear and corrosion. However, literature about the Articular Surface Replacement (ASR) total hip arthroplasty (THA) invariably deals with stems manufactured by DePuy Orthopedics (Warsaw, IN, USA). Nothing is known whether different stems with common 12/14 mm tapers affect failure rate or ion release. 99 ASR THA (88 patients) implanted with CoxaFit or ARGE Geradschaft stems (K-Implant, Hannover, Germany) were retrospectively analyzed. After a mean follow-up of 3.5 years revision rate was 24.5%, mostly due to adverse reaction to metal debris (ARMD). CT scan revealed component loosening in 10.3% and pseudotumoral lesions in 12.6%. Elevated ion concentrations (>7 μg/l) were found in 38.6%. Copyright © 2014 Elsevier Inc. All rights reserved.
... arthroplasty Patient Instructions Elbow replacement - discharge Surgical wound care - open Images Elbow prosthesis References Cohen MS, Chen NC. Total elbow arthroplasty. In: Wolfe SW, Hotchkiss RN, Pederson ...
[Endoprostheses in geriatric traumatology].
Buecking, B; Eschbach, D; Bliemel, C; Knobe, M; Aigner, R; Ruchholtz, S
2017-01-01
Geriatric traumatology is increasing in importance due to the demographic transition. In cases of fractures close to large joints it is questionable whether primary joint replacement is advantageous compared to joint-preserving internal fixation. The aim of this study was to describe the importance of prosthetic joint replacement in the treatment of geriatric patients suffering from frequent periarticular fractures in comparison to osteosynthetic joint reconstruction and conservative methods. A selective search of the literature was carried out to identify studies and recommendations concerned with primary arthroplasty of fractures in the region of the various joints (hip, shoulder, elbow and knee). The importance of primary arthroplasty in geriatric traumatology differs greatly between the various joints. Implantation of a prosthesis has now become the gold standard for displaced fractures of the femoral neck. In addition, reverse shoulder arthroplasty has become an established alternative option to osteosynthesis in the treatment of complex proximal humeral fractures. Due to a lack of large studies definitive recommendations cannot yet be given for fractures around the elbow and the knee. Nowadays, joint replacement for these fractures is recommended only if reconstruction of the joint surface is not possible. The importance of primary joint replacement for geriatric fractures will probably increase in the future. Further studies with larger patient numbers must be conducted to achieve more confidence in decision making between joint replacement and internal fixation especially for shoulder, elbow and knee joints.
Shoulder Arthroplasty, from Indications to Complications: What the Radiologist Needs to Know.
Lin, Dana J; Wong, Tony T; Kazam, Jonathan K
2016-01-01
The replaced shoulder is increasingly encountered by the radiologist, both on a dedicated and incidental basis, in this era of the growing population of aging patients wishing to preserve their mobility and function. Knowledge of the normal biomechanics of the glenohumeral joint-particularly the function of the rotator cuff and the unique relationship of the humeral head to the glenoid-is essential for understanding the need for shoulder replacement and its subsequent complications, because the intent of shoulder arthroplasty is to approximate the normal joint as closely as possible. The most common indications for shoulder arthroplasty are osteoarthritis, inflammatory arthritis, proximal humerus fractures, irreparable rotator cuff tears, rotator cuff arthropathy, and avascular necrosis of the humeral head. Knowledge of the key imaging features of these indications helps facilitate a correlative understanding between the initial diagnosis and the choice of which type of arthroplasty is used-total shoulder arthroplasty, reverse total shoulder arthroplasty, or partial joint replacement (humeral head resurfacing arthroplasty or hemiarthroplasty). The preoperative requirements and usual postoperative appearance of each arthroplasty type are summarized, as well as the complications of shoulder arthroplasty, including those unique to or closely associated with each type of arthroplasty and those that can be encountered with any type of shoulder arthroplasty. ©RSNA, 2016.
The fundamentals of biotribology and its application to spine arthroplasty
Harper, Megan L.; Dooris, Andrew; Paré, Philippe E.
2009-01-01
The biological effect of wear of articulating surfaces is a continued concern with large joint replacements and, likewise, of interest for total disc replacements. There are a number of important biotribological testing parameters that can greatly affect the outcome of a wear study in addition to the implant design and material selection. The current ASTM and ISO wear testing standards/guides for spine arthroplasty leave many choices as testing parameters. These factors include but are not limited to the sequence of kinematics and load, phasing, type of lubricant, and specimen preparation (sterilization and artificial aging). The spinal community should critically assess wear studies and be cognizant of the influence of the selected parameters on the test results. PMID:25802638
Revision total hip arthoplasty: factors associated with re-revision surgery.
Khatod, Monti; Cafri, Guy; Inacio, Maria C S; Schepps, Alan L; Paxton, Elizabeth W; Bini, Stefano A
2015-03-04
The survivorship of implants after revision total hip arthroplasty and risk factors associated with re-revision are not well defined. We evaluated the re-revision rate with use of the institutional total joint replacement registry. The purpose of this study was to determine patient, implant, and surgeon factors associated with re-revision total hip arthroplasty. A retrospective cohort study was conducted. The total joint replacement registry was used to identify patients who had undergone revision total hip arthroplasty for aseptic reasons from April 1, 2001, to December 31, 2010. The end point of interest was re-revision total hip arthroplasty. Risk factors evaluated for re-revision total hip arthroplasty included: patient risk factors (age, sex, body mass index, race, and general health status), implant risk factors (fixation type, bearing surface, femoral head size, and component replacement), and surgeon risk factors (volume and experience). A multivariable Cox proportional hazards model was used. Six hundred and twenty-nine revision total hip arthroplasties with sixty-three (10%) re-revisions were evaluated. The mean cohort age (and standard deviation) was 57.0 ± 12.4 years, the mean body mass index (and standard deviation) was 29.5 ± 6.1 kg/m(2), and most of the patients were women (64.5%) and white (81.9%) and had an American Society of Anesthesiologists score of <3 (52.9%). The five-year implant survival after revision total hip arthroplasty was 86.8% (95% confidence interval, 83.57% to 90.25%). In adjusted models, age, total number of revision surgical procedures performed by the surgeon, fixation, and bearing surface were associated with the risk of re-revision. For every ten-year increase in patient age, the hazard ratio for re-revision decreases by a factor of 0.72 (95% confidence interval, 0.58 to 0.90). For every five revision surgical procedures performed by a surgeon, the risk of revision decreases by a factor of 0.93 (95% confidence interval, 0.86 to 0.99). At the time of revision, a new or retained cemented femoral implant or all-cemented hip implant increases the risk of revision by a factor of 3.19 (95% confidence interval, 1.22 to 8.38) relative to a retained or new uncemented hip implant. A ceramic on a highly cross-linked polyethylene bearing articulation decreases the hazard relative to metal on highly cross-linked polyethylene by a factor of 0.32 (95% confidence interval, 0.11 to 0.95). Metal on constrained bearing increases the hazard relative to metal on highly cross-linked polyethylene by a factor of 3.32 (95% confidence interval, 1.16 to 9.48). When evaluating patient, implant, and surgical factors at the time of revision total hip arthroplasty, age, surgeon experience, implant fixation, and bearing surfaces had significant impacts on the risk of re-revision. Copyright © 2015 by The Journal of Bone and Joint Surgery, Incorporated.
Shoulder arthroplasty in osteoarthritis: current concepts in biomechanics and surgical technique
Merolla, G; Nastrucci, G; Porcellini, G
Shoulder arthroplasty is a technically demanding procedure to restore shoulder function in patients with severe osteoarthritis of the glenohumeral joint. The modern prosthetic system exploit the benefits of modularity and the availibility of additional sizes of the prosthetic components. In this paper we describe the biomechanics of shoulder arthroplasty and the technique for shoulder replacement including total shoulder arthroplasty (TSA) with all-polyethylene and metal-backed glenoid component, humeral head resurfacing and stemless humeral replacement. PMID:24251240
Deciding to have knee or hip replacement
... joint replacement surgery References Harkess JW, Crockarell JR. Arthroplasty of the hip. In: Azar FM, Beaty JH, ... Philadelphia, PA: Elsevier; 2017:chap 3. Mihalko WM. Arthroplasty of the knee. In: Azar FM, Beaty JH, ...
Cip, Johannes; Bach, Christian; Widemschek, Mark; Luegmair, Matthias; Martin, Arno
2015-09-01
The articular surface replacement (ASR) total hip arthroplasty (THA) showed accelerated failure rates due to adverse-reaction to metal debris (ARMD). Literature correlating preoperative with intraoperative revision findings respectively post-revision outcome results are rare. 30 of 99 available ASR THA were revised due to ARMD. Mean post-revision follow-up term was 2.3 years. In part, preoperative data did not correlate with intraoperative revision findings. ARMD was even found in asymptomatic patients with non-elevated ion levels. Postoperative pain and metal ions decreased significantly (P ≤ 0.016). Cobalt decreased faster than chrome. Patients with intraoperative pseudotumors, osteolysis or bilateral THA did not have higher pre- or postoperative ion values (P ≥ 0.053). Females showed higher postoperative chrome levels (P=0.031). One major post-revision complication (femoral nerve palsy) and one re-revision (late onset infection) occurred. Copyright © 2015 Elsevier Inc. All rights reserved.
Questions to ask your doctor after knee replacement
... replacement - after - what to ask your doctor; Knee arthroplasty - after - what to ask your doctor ... Mihalko WM. Arthroplasty of the knee. In: Azar FM, Beaty JH, Canale ST, eds. Campbell's Operative Orthopaedics . 13th ed. Philadelphia, PA: ...
Questions to ask your doctor before knee replacement
... before; Before knee replacement - doctor questions; Before knee arthroplasty - what to ask your doctor ... Mihalko WM. Arthroplasty of the knee. In: Azar FM, Beaty JH, Canale ST, eds. Campbell's Operative Orthopaedics . 13th ed. Philadelphia, PA: ...
Huang, Phil; Lyons, Matt; O'Sullivan, Michael
2018-02-01
Despite the well-documented decline in the use of metal-on-metal (MoM) implants over the last decade, there are still controversies regarding whether all MoM implants are created equally. Complications such as elevated serum metal ion levels, aseptic lymphocyte-dominated vasculitis-associated lesion (ALVAL) and pseudotumours have all been well documented, but recent studies suggest increased risk of infection with MoM bearing surfaces. Most of these studies however have small patient numbers. The purpose of this study was to examine the cumulative incidence of revision for infection of MoM bearing surfaces in primary hip arthroplasty at a national and single-surgeon level. Data was collected from the Australian Orthopaedic Association National Joint Replacement Registry, which contains over 98% of all arthroplasties performed in Australia since 2001. The cumulative incidence of revision for infection was extracted at a national level and single-surgeon level. Two hundred seventy-six thousand eight hundred seventy-eight subjects were documented in the Australian registry. The 10-year cumulative percent revision for infection of MoM bearing surfaces in primary total hip replacement (THR) was 2.5% at a national level, compared to 0.8% for other bearing surfaces. The senior author contributed 1755 subjects with 7-year follow-up and a cumulative percent revision for infection of MoM bearing surfaces in primary THR of 36.9%, compared to 2.0% for other bearing surfaces. The cumulative percent of revision of MoM bearing surfaces is higher compared to other bearing surfaces; this is especially pronounced in cumulative percent of revision for infection. There was a higher cumulative percent of revision for infection in MoM bearings surfaces (in particular, large-head MoM) compared to other bearing surfaces at both the national and individual-surgeon level.
Palejwala, Sheri K; Rughani, Anand I; Dumont, Travis M
2017-03-01
Treatment of cervical radiculopathy with disk arthroplasty has been approved by the U.S. Food and Drug Administration since 2007. Recently, a significant increase in clinical data including mid- and long-term follow-up has become available, demonstrating the superiority of disk arthroplasty compared with anterior discectomy and fusion. The aim of this project is to assess the nationwide use of cervical disk arthroplasty. The University Healthcare Consortium database was accessed for all elective cases of patients treated for cervical radiculopathy caused by disk herniation (International Classification of Diseases [ICD] 722.0) from the fourth quarter of 2012 to the third quarter of 2015. Within this 3-year window, temporal and socioeconomic trends in the use of cervical disk replacement for this diagnosis were assessed. Three thousand four hundred forty-six cases were identified. A minority of cases (10.7%) were treated with disk arthroplasty. Median hospital charges were comparable for cervical disk replacement ($15,606) and anterior cervical fusion ($15,080). However, utilization was seen to increase by nearly 70% during the timeframe assessed. Disk arthroplasty was performed in 8% of patients in 2012 to 2013, compared with 13% of cases in 2015. Disk replacement use was more common for self-paying patients, patients with private insurance, and patients with military-based insurance. There was widespread variation in the use of cervical disk replacement between regions, with a nadir in northeastern states (8%) and a peak in western states (20%). Over a short, 3 -year period there has been an increase in the treatment of symptomatic cervical radiculopathy with disk arthroplasty. The authors predict a further increase in cervical disk arthroplasty in upcoming years. Copyright © 2016 Elsevier Inc. All rights reserved.
Ebina, Kosuke; Hirao, Makoto; Hashimoto, Jun; Nampei, Akihide; Shi, Kenrin; Tomita, Tetsuya; Futai, Kazuma; Kunugiza, Yasuo; Noguchi, Takaaki; Yoshikawa, Hideki
2017-09-01
To clarify the difference of patient-based outcome between joint-preserving arthroplasty and resection-replacement arthroplasty in forefoot surgery for patients with rheumatoid arthritis (RA). A total of 63 feet of 49 RA patients who underwent forefoot surgery were asked to answer pre-operative and post-operative self-administered foot evaluation questionnaire (SAFE-Q). Patients were treated with either (1) metatarsal head resection-replacement arthroplasty (28 feet, post-operative mean age 63.8 years, follow-up 4.2 years, DAS28-CRP 2.2) or (2) metatarsophalangeal joint-preserving arthroplasty (35 feet, post-operative mean age 63.1 years, follow-up 3.6 years, DAS28-CRP 2.1) at each surgeon's discretion. Mean pre-operative and post-operative subscale scores of SAFE-Q of group (1) and (2) were as follows. Pain and pain-related [(1) pre-op 36.8 to post-op 75.0 vs. (2) pre-op 42.2 to post-op 82.6], physical functioning and daily-living [(1) 43.2-68.8 vs. (2) 52.778.1], social functioning [(1) 44.3-72.0 vs. (2) 52.5-81.9], general health and well-being [(1) 48.4-68.4 vs. (2) 45.5-84.4], and shoe-related [(1) 30.1-50.3 vs. (2) 30.6-64.4]. Both general health and well-being subscale scores (p < 0.05) and shoe-related subscale scores (p < 0.05) were significantly more improved in group (2) compared with group (1). Joint-preserving arthroplasty resulted in better patient-based outcomes than resection-replacement arthroplasty.
Management of the failed biaxial wrist replacement.
Talwalkar, S C; Hayton, M J; Trail, I A; Stanley, J K
2005-06-01
Nine cases of failed biaxial wrist replacement underwent revision surgery and subsequent clinical and radiographic assessment at a mean follow-up of 28 months. Clinical assessment included the hospital for special surgery (HSS) and activities of daily living scoring systems. Five patients had a revision biaxial wrist replacement, three had wrist fusions and two underwent an excision arthroplasty. The mean HSS score was 73 for the revision biaxial replacements, 63 for the wrist fusions and 92 for the excision arthroplasties. The mean activities for daily living score was 16 for the revision biaxial replacements, 14 for the wrist fusion and 20 for the excision arthroplasties. Despite the experience of implant failure, six patients would still choose a primary wrist replacement again. All patients in this small series appear to have had good clinical outcomes. Revision to another wrist replacement appears no worse than a wrist fusion in the short term and patients value the preservation of movement that an implant offers.
Friesenbichler, Joerg; Maurer-Ertl, Werner; Sadoghi, Patrick; Lovse, Thomas; Windhager, Reinhard; Leithner, Andreas
2012-03-01
The effects of systemic metal ion exposure in patients with implants made of common prosthetic alloys continue to be a matter of concern. The aim of the study was to determine the measurement values of cobalt (Co), chromium (Cr) and molybdenum (Mo) in serum following rotating-hinge knee arthroplasty. Blood was taken from 25 patients [mean follow-up 35 (range nine to 67) months] treated with megaprostheses (n=17) or standard rotating-hinge devices (n=8) and analysed using electrothermal graphite furnace atomic absorption spectrometry (ET-ASS). Determining the concentrations of metal ions following rotating-hinge knee arthroplasty revealed increments for Co and Cr but not Mo. Metal ion release was significantly higher in patients with megaprostheses compared to a standard rotating-hinge knee device (Co p=0,024; Cr p=0.025). The authors believe there might be an additional metal ion release from the surface of the prosthesis and not only from the articulating surfaces because, in cases of rotating-hinge knee prosthesis, there is a metal-on-polyethylene articulation and not a direct metal-on-metal junction. Nevertheless, long-term studies are required to determine adverse effects of Co, Cr and Mo following total hip replacement and total knee arthroplasty.
Hip and knee replacement in osteogenesis imperfecta.
Papagelopoulos, P J; Morrey, B F
1993-04-01
Five total hip and three total knee arthroplasties were performed, from 1969 to 1990, in six patients who had osteogenesis imperfecta. The patients who had a hip arthroplasty were followed for a mean of seven years, and those who had a knee arthroplasty, for a mean of ten years. Postoperatively, all had relief of pain and were able to walk; one patient used a walker and two used a cane. The only postoperative complication was an intrapelvic protrusion of the acetabular component six years after a bipolar hip replacement.
Fluorescence and UV-vis Spectroscopy of Synovial Fluids
NASA Astrophysics Data System (ADS)
Pinti, Marie J.; Stojilovic, Nenad; Kovacik, Mark W.
2009-10-01
Total joint arthroplasty involves replacing the worn cartilaginous surfaces of the joint with man-made materials that are designed to be biocompatible and to withstand mechanical stresses. Commonly these bearing materials consist of metallic alloys (TiAlV or CoCrMo) and UHMWPE. Following joint arthroplasty, the normal generation of micro-metallic wear debris particles that dislodge from the prosthesis has been shown to cause inflammatory aseptic osteolysis (bone loss) that ultimately results in the failure of the implant. Here we report our results on the novel use of Fluorescence and UV-vis spectroscopy to investigate the metallic content of synovial fluid specimens taken from postoperative total knee arthroplasties. Preliminary finding showed presence of alumina and chromium is some specimens. The ability to detect and monitor the wear rate of these implants could have far reaching implications in the prevention of metallic wear-debris induced osteolysis and impending implant failure.
Mycobacterium smegmatis infection of a prosthetic total knee arthroplasty.
Saffo, Zaid; Ognjan, Anthony
2016-01-01
The most common organisms causing prosthetic knee joint infections are staphylococci. However, arthroplasty infections with atypical microbial pathogens, such as Mycobacteria can occur. Due to the rarity of mycobacterial prosthetic joint infections, diagnosis, treatment, and management of these atypical infections represent a clinical challenge. A 71-year old female post-operative day 40 after a left total knee arthroplasty was hospitalized secondary to left knee pain and suspected arthroplasty infection. She had failed outpatient oral antimicrobial treatment for superficial stitch abscess; and outpatient IV/Oral antimicrobials for a clinical postoperative septic bursitis. Ultimately, resection arthroplasty with operative tissue acid fast bacterial cultures demonstrated growth of the Mycobacterium smegmatis group. Post-operatively, she completed a combination course of oral doxycycline and levofloxacin and successfully completed a replacement arthroplasty with clinical and microbial resolution of the infection. To our knowledge, literature review demonstrates three case of knee arthroplasty infection caused by the Mycobacterium smegmatis group. Correspondingly, optimal surgical procedures and antimicrobial management including antimicrobial selection, treatment duration are not well defined. Presently, the best treatment options consists of two step surgical management including prosthesis hardware removal followed by extended antimicrobial therapy, followed by consideration for re-implantation arthroplasty. Our case illustrates importance of considering atypical mycobacterial infections in post-operative arthroplasty infections not responding to traditional surgical manipulations and antimicrobials. For an arthroplasty infection involving the atypical Mycobacterium smegmatis group, two step arthroplasty revision, including arthroplasty resection, with a combination of oral doxycycline and levofloxacin can lead to successful infection resolution, allowing for a successful replacement arthroplasty.
Taking care of your new hip joint
Hip arthroplasty - precautions; Hip replacement - precautions; Osteoarthritis - hip; Osteoarthritis - knee ... Saunders; 2015:chap 61. Harkess JW, Crockarell JR. Arthroplasty of the hip. In: Azar FM, Beaty JH, ...
Wear analysis and finishing of bioceramic implant surfaces.
Denkena, Berend; Reichstein, Martin; van der Meer, Marijke; Ostermeier, Sven; Hurschler, Christof
2008-01-01
A primary cause for revision operations of joint replacements is the implant loosening, due to immune reactions resulting from the agglomeration of polyethylene wear debris. Motivated by the successful application of bioceramic materials in hip joint prostheses, a trend towards the development of hard implant materials has occurred. Nonetheless in the area of total knee arthroplasty (TKA), modern efforts have still utilized polyethylene as the tibial-inlay joint component. The use of bioceramic hard-hard-pairings for total knee arthroplasty has been prevented by the complex kinematics and geometries required. Ceramics cannot cope with non-uniform loads, which suggests the need for new designs appropriate to the material. Furthermore, biomechanical requirements should be considered. A rolling-gliding wear simulator, which reproduces the movements and stresses of the knee joint on specimens of simplified geometry, has therefore been developed. High-precision machining processes for free formed bioceramic surfaces, with suitable grinding and polishing tools which adjust to constantly changing contact conditions, are essential. The goal is to put automated finishing in one clamping with five simultaneous controlled axes into practice. The developed manufacturing technologies will allow the advantageous bioceramic materials to be applied and accepted for more complex joint replacements such as knee prostheses.
Daftari, Tapan K; Chinthakunta, Suresh R; Ingalhalikar, Aditya; Gudipally, Manasa; Hussain, Mir; Khalil, Saif
2012-10-01
Despite encouraging clinical outcomes of one-level total disc replacements reported in literature, there is no compelling evidence regarding the stability following two-level disc replacement and hybrid constructs. The current study is aimed at evaluating the multidirectional kinematics of a two-level disc arthroplasty and hybrid construct with disc replacement adjacent to rigid circumferential fusion, compared to two-level fusion using a novel selectively constrained radiolucent anterior lumbar disc. Nine osteoligamentous lumbosacral spines (L1-S1) were tested in the following sequence: 1) Intact; 2) One-level disc replacement; 3) Hybrid; 4) Two-level disc replacement; and 5) Two-level fusion. Range of motion (at both implanted and adjacent level), and center of rotation in sagittal plane were recorded and calculated. At the level of implantation, motion was restored when one-level disc replacement was used but tended to decrease with two-level disc arthroplasty. The findings also revealed that both one-level and two-level disc replacement and hybrid constructs did not significantly change adjacent level kinematics compared to the intact condition, whereas the two-level fusion construct demonstrated a significant increase in flexibility at the adjacent level. The location of center of rotation in the sagittal plane at L4-L5 for the one-level disc replacement construct was similar to that of the intact condition. The one-level disc arthroplasty tended to mimic a motion profile similar to the intact spine. However, the two-level disc replacement construct tended to reduce motion and clinical stability of a two-level disc arthroplasty requires additional investigation. Hybrid constructs may be used as a surgical alternative for treating two-level lumbar degenerative disc disease. Published by Elsevier Ltd.
Standifird, Tyler W; Saxton, Arnold M; Coe, Dawn P; Cates, Harold E; Reinbolt, Jeffrey A; Zhang, Songning
2016-01-01
This study compared biomechanics during stair ascent in replaced and non-replaced limbs of total knee arthroplasty (TKA) patients with control limbs of healthy participants. Thirteen TKA patients and fifteen controls performed stair ascent. Replaced and non-replaced knees of TKA patients were less flexed at contact compared to controls. The loading response peak knee extension moment was greater in control and non-replaced knees compared with replaced. The push-off peak knee abduction moment was elevated in replaced limbs compared to controls. Loading and push-off peak hip abduction moments were greater in replaced limbs compared to controls. The push-off peak hip abduction moment was greater in non-replaced limbs compared to controls. Future rehabilitation protocols should consider the replaced knee and also the non-replaced knee and surrounding joints. Copyright © 2016 Elsevier Inc. All rights reserved.
Extra-articular deformity correction using Taylor spatial frame prior to total knee arthroplasty.
Tawari, Gautam J K; Maheshwari, Rajan; Madan, Sanjeev S
2018-03-20
A good long-term outcome following a total knee arthroplasty relies on restoration of the mechanical axis and effective soft tissue balancing of the prosthetic knee. Arthroplasty surgery in patients with secondary osteoarthritis of the knee with an extra-articular tibial deformity is a complex and challenging procedure. The correction of mal-alignment of the mechanical axis is associated with unpredictable result and with higher revision rates. Single-staged deformity correction and replacement surgery often result in the use of constraint implants. We describe our experience with staged correction of deformity using a Taylor Spatial Frame (TSF) followed by total knee arthroplasty in these patients and highlight the advantage of staged approach. The use of TSF fixator for deformity correction prior to a primary total knee arthroplasty has not been described in the literature. We describe three cases of secondary osteoarthritis of the knee associated with multiplanar tibial deformity treated effectively with a total knee arthroplasty following deformity correction and union using a TSF. All patients had an improved Knee Society score and Oxford Knee score postoperatively and were satisfied with their replacement outcome. Staged deformity correction followed by arthroplasty allows the use of standard primary arthroplasty implants with predicable results and flexible aftercare. This approach may also provide significant improvement of patient symptoms following correction of deformity resulting in deferment of the arthroplasty surgery.
Maxwell, Jessica; Niu, Jingbo; Singh, Jasvinder A.; Nevitt, Michael C.; Law, Laura Frey; Felson, David
2013-01-01
Background: Some of the poor functional outcomes of knee arthroplasty may be due to pain in the contralateral, unreplaced knee. We investigated the relationship between the preoperative pain status of the contralateral knee and the risk of a poor postoperative functional outcome in patients who underwent knee arthroplasty. Methods: We analyzed data on 271 patients in the Multicenter Osteoarthritis Study who had undergone knee arthroplasty since the time of enrollment. Eighty-six percent of these patients were white, 72% were female, and the mean age was sixty-seven years. The severity of pain in the knee contralateral to the one that was replaced was measured before the knee arthroplasty with use of the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) pain scale, with the scores being grouped into four categories (0, 1 to 4, 5 to 9, and 10 to 20). Poor post-arthroplasty function six months or more after surgery was determined with use of the Patient Acceptable Symptom State (PASS) outcome tool and a clinical performance measure of walking speed. We evaluated the relationship between contralateral pain severity and the functional outcomes with use of Poisson regression. Results: Seventy-two (27%) of 264 patients demonstrated poor post-arthroplasty function by failing to attain the threshold PASS score, and seventy-six (30%) of 250 subjects had a slow walking speed. As the pre-arthroplasty pain in the contralateral knee increased, there was a steady increase in the proportion with poor post-arthroplasty function (p < 0.0001 for PASS and p = 0.04 for slow walking speed). Compared with patients who had no pre-arthroplasty pain in the contralateral knee, those in the highest category of contralateral pain severity had 4.1 times the risk (95% confidence interval, 1.5 to 11.5) of having poor self-reported post-arthroplasty function. Patients in whom both knees had been replaced at the time of outcome collection were less likely to have poor self-reported function than those in whom only one knee had been replaced. Conclusions: Preoperative pain in the contralateral knee is strongly associated with self-reported post-arthroplasty functional outcome and may therefore be a useful indicator of prognosis or a potential target of perioperative intervention. Level of Evidence: Prognostic Level II. See Instructions for Authors for a complete description of levels of evidence. PMID:23780536
Collateral ligament strains during knee joint laxity evaluation before and after TKA.
Delport, Hendrik; Labey, Luc; De Corte, Ronny; Innocenti, Bernardo; Vander Sloten, Jos; Bellemans, Johan
2013-08-01
Passive knee stability is provided by the soft tissue envelope. There is consensus among orthopedic surgeons that good outcome in Total Knee Arthroplasty requires equal tension in the medial/lateral compartment of the knee joint, as well as equal tension in the flexion/extension gap. The purpose of this study was to quantify the ligament laxity in the normal non-arthritic knee before and after Posterior-Stabilized Total Knee Arthroplasty. We hypothesized that the Medial/Lateral Collateral Ligament shows minimal changes in length when measured directly by extensometers in the native human knee during varus/valgus laxity testing. We also hypothesized that due to differences in material properties and surface geometry, native laxity is difficult to reconstruct using a Posterior-Stabilized Total Knee. Six specimens were used to perform this in vitro cadaver test using extensometers to provide numerical values for laxity and varus-valgus tilting in the frontal plane. This study enabled a precise measurement of varus-valgus laxity as compared with the clinical assessment. The strains in both ligaments in the replaced knee were different from those in the native knee. Both ligaments were stretched in extension, in flexion the Medial Collateral Ligament tends to relax and the Lateral Collateral Ligament remains tight. As material properties and surface geometry of the replaced knee add stiffness to the joint, we recommend to avoid overstuffing the joint, when using this type of Posterior-Stabilized Total Knee Arthroplasty, in order to obtain varus/valgus laxity close to the native joint. Copyright © 2013 Elsevier Ltd. All rights reserved.
Ebina, Kosuke; Hirao, Makoto; Takagi, Keishi; Ueno, Sachi; Morimoto, Tokimitsu; Matsuoka, Hozo; Kitaguchi, Kazuma; Iwahashi, Toru; Hashimoto, Jun; Yoshikawa, Hideki
2017-01-01
The purpose of this retrospective study is to clarify the difference in plantar pressure distribution during walking and related patient-based outcomes between forefoot joint-preserving arthroplasty and resection-replacement arthroplasty in patients with rheumatoid arthritis (RA). Four groups of patients were recruited. Group1 included 22 feet of 11 healthy controls (age 48.6 years), Group2 included 36 feet of 28 RA patients with deformed non-operated feet (age 64.8 years, Disease activity score assessing 28 joints with CRP [DAS28-CRP] 2.3), Group3 included 27 feet of 20 RA patients with metatarsal head resection-replacement arthroplasty (age 60.7 years, post-operative duration 5.6 years, DAS28-CRP 2.4), and Group4 included 34 feet of 29 RA patients with metatarsophalangeal (MTP) joint-preserving arthroplasty (age 64.6 years, post-operative duration 3.2 years, DAS28-CRP 2.3). Patients were cross-sectionally examined by F-SCAN II to evaluate walking plantar pressure, and the self-administered foot evaluation questionnaire (SAFE-Q). Twenty joint-preserving arthroplasty feet were longitudinally examined at both pre- and post-operation. In the 1st MTP joint, Group4 showed higher pressure distribution (13.7%) than Group2 (8.0%) and Group3 (6.7%) (P<0.001). In the 2nd-3rd MTP joint, Group4 showed lower pressure distribution (9.0%) than Group2 (14.5%) (P<0.001) and Group3 (11.5%) (P<0.05). On longitudinal analysis, Group4 showed increased 1st MTP joint pressure (8.5% vs. 14.7%; P<0.001) and decreased 2nd-3rd MTP joint pressure (15.2% vs. 10.7%; P<0.01) distribution. In the SAFE-Q subscale scores, Group4 showed higher scores than Group3 in pain and pain-related scores (84.1 vs. 71.7; P<0.01) and in shoe-related scores (62.5 vs. 43.1; P<0.01). Joint-preserving arthroplasty resulted in higher 1st MTP joint and lower 2nd-3rd MTP joint pressures than resection-replacement arthroplasty, which were associated with better patient-based outcomes.
Attenuation of radionuclide activity by metal-cup arthroplasties
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rosenthall, L.; Rosenthall, S.
1985-04-01
The half-value layers of stainless steel, bone cement, and polyethylene were measured for /sup 99m/Tc, /sup 67/Ga, /sup 111/In, and /sup 201/TI to render some insight into the attenuating effects of the metallic cup and other components used in surface-replacement revision arthroplasty. On theoretic consideration, a twofold increase in /sup 99m/Tc-methylene diphosphonate in bone inside the cup should not be attenuated to the point of escaping detection on the radionuclide images of the hip. /sup 67/Ga, using the 184 and 300 keV peaks, and /sup 111/In have greater half-value layers than /sup 99m/Tc and are subject to less attenuation bymore » the metallic cup.« less
Aminata, Iman; Lee, Soo-Ho; Chang, Jae-Suk; Lee, Choon-Sung; Chun, Jae-Myeung; Park, Jin-Woong; Pawaskar, Aditya; Jeon, In-Ho
2012-12-15
This study aims to evaluate perioperative mortality and morbidity after total hip replacement in liver transplant recipients and suggesting safety guidelines. Hip replacement surgery is one of the most common elective surgeries even for organ transplant recipients. However, there is a paucity of literature addressing the morbidity and complications of hip replacement surgery for liver transplant recipients. We analyzed retrospectively 33 arthroplasty cases in 20 liver transplant recipients carried out in a single center from 2005 to 2011. All perioperative clinical and laboratory data were evaluated together with early and late morbidity and mortality. Of 2253 liver transplant recipients, 20 (0.9%) patients underwent 33 total hip arthroplasties. Thirty-two arthroplasties were performed for avascular necrosis of the femoral head, whereas only one was performed for osteoarthritis. There was no death, liver failure, or infection within 30 days after surgery. Three patients showed elevated liver enzyme more than 5 times the normal value, but it eventually decreased to normal within 1 week. Of 33 cases of arthroplasty, postoperative blood transfusion was needed in 14 cases with 1 case receiving more than 4 U. On long-term follow-up, no patients have developed periprosthetic fracture, implant loosening, or liver failure. All patients showed good to excellent postoperative Harris hip score. In this series, we can infer that hip replacement surgery in liver transplantation patients is safe and gives a reliably good result. Some preoperative conditions should be obtained to reduce postoperative morbidity.
Amirtharajah, Mohana; Fufa, Duretti; Lightdale, Nina; Weiland, Andew
2011-01-01
The purpose of this study was to evaluate the one-year clinical, radiologic and patient-reported results of surface-replacing proximal interphalangeal joint arthroplasty (SR-PIP) of the hand. Fifteen patients with 18 joints underwent the procedure, and nine patients with 11 joints had follow-up of at least one year's duration. Of these joints, six had a diagnosis of osteoarthritis with no history of trauma, three had post-traumatic arthritis, one had psoriatic arthritis, and one had erosive arthritis. The mean clinical follow-up was at 3.3 years, and the mean radiographic follow-up was at 3.1 years. The average post-operative gain in range of motion at the PIP joint was 28 degrees and was statistically significant. Six patients completed self-reported questionnaires at a mean of 4.8 years post-operatively. The mean Disabilities of the Arm, Shoulder and Hand (DASH) score post-operatively was 17, and the Michigan Hand Questionnaire (MHQ) score for overall satisfaction was 70. There were three complications but only one reoperation. Seven of 11 joints showed some evidence of subsidence on follow-up radiographic examination. However, no joints were revised sec-ondary to loosening. Longer follow-up is needed to determine if this observable radiologic subsidence leads to symptomatic loosening of the implant PMID:22096433
Connelly, James W; Galea, Vincent P; Laaksonen, Inari; Matuszak, Sean J; Madanat, Rami; Muratoglu, Orhun; Malchau, Henrik
2018-04-19
The purpose of this study was to identify which patient and clinical factors are predictive of adverse local tissue reaction (ALTR) and to use these factors to create a highly sensitive algorithm for indicating metal artifact reduction sequence magnetic resonance imaging (MARS-MRI) in Articular Surface Replacement (ASR) XL total hip arthroplasty patients. Our secondary aim was to compare our algorithm to existing national guidelines on when to take MARS-MRI in metal-on-metal total hip arthroplasty patients. The study consisted of 137 patients treated with unilateral ASR XL implants from a prospective, multicenter study. Patients underwent MARS-MRI regardless of clinical presentation at a mean of 6.2 (range, 3.3-10.4) years from surgery. Univariate and multivariate analyses were conducted to determine which variables were predictive of ALTR. Predictors were used to create an algorithm to indicate MARS-MRI. Finally, we compared our algorithm's ability to detect ALTR to existing guidelines. We found a visual analog scale pain score ≥2 (odds ratio [OR] = 2.53; P = .023), high blood cobalt (OR = 1.05; P = .023), and male gender (OR = 2.37; P = .034) to be significant predictors of ALTR presence in our cohort. The resultant algorithm achieved 86.4% sensitivity and 60.2% specificity in detecting ALTR within our cohort. Our algorithm had the highest area under the curve and was the only guideline that was significantly predictive of ALTR (P = .014). Our algorithm including patient-reported pain and sex-specific cutoffs for blood cobalt levels could predict ALTR and indicate MARS-MRI in our cohort of ASR XL metal-on-metal patients with high sensitivity. Level II, diagnostic study. Copyright © 2018 Elsevier Inc. All rights reserved.
Return to sports after shoulder arthroplasty
Johnson, Christine C; Johnson, Daniel J; Liu, Joseph N; Dines, Joshua S; Dines, David M; Gulotta, Lawrence V; Garcia, Grant H
2016-01-01
Many patients prioritize the ability to return to sports following shoulder replacement surgeries, including total shoulder arthroplasty (TSA), reverse total shoulder arthroplasty (RTSA), and hemiarthroplasty (HA). While activity levels after hip and knee replacements have been well-established in the literature, studies on this topic in the field of shoulder arthroplasty are relatively limited. A review of the literature regarding athletic activity after shoulder arthroplasty was performed using the PubMed database. All studies relevant to shoulder arthroplasty and return to sport were included. The majority of patients returned to their prior level of activity within six months following TSA, RTSA, and shoulder HA. Noncontact, low demand activities are permitted by most surgeons postoperatively and generally have higher return rates than contact sports or high-demand activities. In some series, patients reported an improvement in their ability to participate in sports following the arthroplasty procedure. The rates of return to sports following TSA (75%-100%) are slightly higher than those reported for HA (67%-76%) and RTSA (75%-85%). Patients undergoing TSA, RTSA, and shoulder HA should be counseled that there is a high probability that they will be able to return to their preoperative activity level within six months postoperatively. TSA has been associated with higher rates of return to sports than RTSA and HA, although this may reflect differences in patient population or surgical indication. PMID:27672564
Metsna, Vahur; Vorobjov, Sigrid; Lepik, Katrin; Märtson, Aare
2014-08-01
Attempts to relate patellar cartilage involvement to anterior knee pain (AKP) have yielded conflicting results. We determined whether the condition of the cartilage of the patella at the time of knee replacement, as assessed by the OARSI score, correlates with postsurgical AKP. We prospectively studied 100 patients undergoing knee arthroplasty. At surgery, we photographed and biopsied the articular surface of the patella, leaving the patella unresurfaced. Following determination of the microscopic grade of the patellar cartilage lesion and the stage by analyzing the intraoperative photographs, we calculated the OARSI score. We interviewed the patients 1 year after knee arthroplasty using the HSS patella score for diagnosis of AKP. 57 of 95 patients examined had AKP. The average OARSI score of painless patients was 13 (6-20) and that of patients with AKP was 15 (6-20) (p = 0.04). Patients with OARSI scores of 13-24 had 50% higher risk of AKP (prevalence ratio = 1.5, 95% CI: 1.0-2.3) than patients with OARSI scores of 0-12. The depth and extent of the cartilage lesion of the knee-cap should be considered when deciding between the various options for treatment of the patella during knee replacement.
Sandri, Andrea; Sambugaro, Elena
2013-01-01
The incidence and severity of heterotopic ossification (HO) in two homogeneous groups of patients that received surface replacement arthroplasty (SRA) and conventional total hip arthroplasty (THA) were evaluated retrospectively. Thirty-nine patients undergoing 42 hip resurfacing procedures and 41 primary cementless THAs through an anterolateral approach received a 10-day course of 150 mg/die of indomethacin postoperatively. The median surgical time was 190 minutes and 156 minutes, respectively (P < 0.003). At a minimum 1-year followup, the development of HO was assessed on standard X-ray using Brooker grading. Ectopic bone formation was detected in five cases (11.9%, two Brooker grade I and three grade II) in the SRA group and in 14 hips (34.1%, 12 grade I and two grade II) treated with conventional THA, but the difference was not significant (P < 0.11). No clinically relevant periprosthetic ossification (Brooker III or IV) occurred in both groups. Although the difference was not statistically significant, the incidence of HO after SRA was lower than conventional THA. More extensive soft tissue trauma, bone debris, and longer operative time in hip resurfacing are not likely to be absolute risk factors for HO. Further investigations including larger patient populations are needed to confirm these findings. PMID:23865045
Visualization of 3D elbow kinematics using reconstructed bony surfaces
NASA Astrophysics Data System (ADS)
Lalone, Emily A.; McDonald, Colin P.; Ferreira, Louis M.; Peters, Terry M.; King, Graham J. W.; Johnson, James A.
2010-02-01
An approach for direct visualization of continuous three-dimensional elbow kinematics using reconstructed surfaces has been developed. Simulation of valgus motion was achieved in five cadaveric specimens using an upper arm simulator. Direct visualization of the motion of the ulna and humerus at the ulnohumeral joint was obtained using a contact based registration technique. Employing fiducial markers, the rendered humerus and ulna were positioned according to the simulated motion. The specific aim of this study was to investigate the effect of radial head arthroplasty on restoring elbow joint stability after radial head excision. The position of the ulna and humerus was visualized for the intact elbow and following radial head excision and replacement. Visualization of the registered humerus/ulna indicated an increase in valgus angulation of the ulna with respect to the humerus after radial head excision. This increase in valgus angulation was restored to that of an elbow with a native radial head following radial head arthroplasty. These findings were consistent with previous studies investigating elbow joint stability following radial head excision and arthroplasty. The current technique was able to visualize a change in ulnar position in a single DoF. Using this approach, the coupled motion of ulna undergoing motion in all 6 degrees-of-freedom can also be visualized.
How much arthritis is too much for hip arthroscopy: a systematic review.
Domb, Benjamin G; Gui, Chengcheng; Lodhia, Parth
2015-03-01
The purpose of this study was to determine the extent of preoperative osteoarthritis (OA) that precludes benefit from hip arthroscopy by systematically reviewing the literature on hip arthroscopy in the setting of OA. We searched the Medline and PubMed databases using the following Medical Subject Heading terms: arthritis, osteoarthritis, chondral damage, chondral injury, chondral delamination, and hip arthroscopy. Two authors independently reviewed the literature and included articles if they were in the English language; commented on preoperative factors, parameters, physical examination, or diagnostic testing that may be evidence of cartilage damage and/or arthritis; contained outcome data on patients undergoing hip arthroscopy; and had a sample size of at least 10 patients with arthritic changes in the hip. We excluded review articles, technique articles, articles with overlapping patient populations, articles with hip arthroscopy used as an adjunct to an open procedure, articles with inflammatory and septic arthritis, and articles with a mean age younger than 18 years. Our search identified 518 articles, of which 15 met the inclusion and exclusion criteria. Two thousand fifty-one hips underwent arthroscopy at a mean patient age of 40.2 years. Of these, 1,195 hips had signs of OA. There were 345 conversions to total hip arthroplasty/surface replacement arthroplasty. Of these patients, 274 had OA. Eight patient-reported outcome instruments were used. Factors influencing outcomes were preoperative OA, age, chondral damage, femoroacetabular impingement, and duration of symptoms. Current evidence is insufficient to define a cutoff for how much arthritis is too much for hip arthroscopy. However, this analysis shows that patients with a Tönnis grade of 1 or greater or a joint space of 2 mm or less are less likely to benefit from hip arthroscopy and more likely to require conversion to total hip arthroplasty/surface replacement arthroplasty. Postoperative scores on patient-reported outcome instruments are lower in the arthritic population at follow-up compared with their nonarthritic counterparts. Level IV, systematic review of Level III and IV studies. Copyright © 2015 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Wong, James Min-Leong; Liu, Yen-Liang; Graves, Stephen; de Steiger, Richard
2015-11-01
More than 15,000 primary hip resurfacing arthroplasties have been recorded by the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) with 884 primary procedures requiring revision for reasons other than infection, a cumulative percent revision rate at 12 years of 11%. However, few studies have reported the survivorship of these revision procedures. (1) What is the cumulative percent rerevision rate for revision procedures for failed hip resurfacings? (2) Is there a difference in rerevision rate among different types of revision or bearing surfaces? The AOANJRR collects data on all primary and revision hip joint arthroplasties performed in Australia and after verification against health department data, checking of unmatched procedures, and subsequent retrieval of unreported procedures is able to obtain an almost complete data set relating to hip arthroplasty in Australia. Revision procedures are linked to the known primary hip arthroplasty. There were 15,360 primary resurfacing hip arthroplasties recorded of which 884 had undergone revision and this was the cohort available to study. The types of revisions were acetabular only, femoral only, or revision of both acetabular and femoral components. With the exception of the acetabular-only revisions, all revisions converted hip resurfacing arthroplasties to conventional (stemmed) total hip arthroplasties (THAs). All initial revisions for infection were excluded. The survivorship of the different types of revisions and that of the different bearing surfaces used were estimated using the Kaplan-Meier method and compared using Cox proportional hazard models. Cumulative percent revision was calculated by determining the complement of the Kaplan-Meier survivorship function at that time multiplied by 100. Of the 884 revisions recorded, 102 underwent further revision, a cumulative percent rerevision at 10 years of 26% (95% confidence interval, 19.6-33.5). There was no difference in the rate of rerevision between acetabular revision and combined femoral and acetabular revision (hazard ratio [HR], 1.06 [0.47-2], p = 0.888), femoral revision and combined femoral and acetabular revision (HR, 1.00 [0.65-2], p = 0.987), and acetabular revision and femoral revision (HR, 1.06 [0.47-2], p = 0.893). There was no difference in the rate of rerevision when comparing different bearing surfaces (metal-on-metal versus ceramic-on-ceramic HR, 0.46 [0.16-1.29], p = 0.141; metal-on-metal versus ceramic-on-crosslinked polyethylene HR, 0.51 [0.15-1.76], p = 0.285; metal-on-metal versus metal-on-crosslinked polyethylene HR, 0.62 [0.20-1.89], p = 0.399; and metal-on-metal versus oxinium-on-crosslinked polyethylene HR, 0.53 [0.14-2.05], p = 0.356). Revision of a primary hip resurfacing arthroplasty is associated with a high risk of rerevision. This study may help surgeons guide their patients about the outcomes in the longer term after the first revision of hip resurfacing arthroplasty. Level III, therapeutic study.
Basic Science Considerations in Primary Total Hip Replacement Arthroplasty
Mirza, Saqeb B; Dunlop, Douglas G; Panesar, Sukhmeet S; Naqvi, Syed G; Gangoo, Shafat; Salih, Saif
2010-01-01
Total Hip Replacement is one of the most common operations performed in the developed world today. An increasingly ageing population means that the numbers of people undergoing this operation is set to rise. There are a numerous number of prosthesis on the market and it is often difficult to choose between them. It is therefore necessary to have a good understanding of the basic scientific principles in Total Hip Replacement and the evidence base underpinning them. This paper reviews the relevant anatomical and biomechanical principles in THA. It goes on to elaborate on the structural properties of materials used in modern implants and looks at the evidence base for different types of fixation including cemented and uncemented components. Modern bearing surfaces are discussed in addition to the scientific basis of various surface engineering modifications in THA prostheses. The basic science considerations in component alignment and abductor tension are also discussed. A brief discussion on modular and custom designs of THR is also included. This article reviews basic science concepts and the rationale underpinning the use of the femoral and acetabular component in total hip replacement. PMID:20582240
Calliess, Tilman; Schado, Ssuheib; Richter, Berna I; Becher, Christoph; Ezechieli, Marco; Ostermeier, Sven
2014-02-01
Previous biomechanical studies have shown that bi-cruciate retaining knee replacement does not significantly alter normal knee kinematics, however, there are no data on the influence of a combined medial and patellofemoral bi-compartimental arthroplasty. The purpose of this in vitro study was to evaluate the effect of different replacement scenarios with a modular partial knee replacement system on the amount of quadriceps force required to extend the knee during an isokinetic extension cycle. Ten human knee specimens were tested in a kinematic knee simulator under (1) physiologic condition and after subsequent implantation of (2) a medial unicondylar and (3) a trochlear replacement. An isokinetic extension cycle of the knee with a constant extension moment of 31 Nm was simulated. The resulting quadriceps extension force was measured from 120° to full knee extension. The quadriceps force curve described a typically sinusoidal characteristic before and after each replacement scenario. The isolated medial replacement resulted in a slightly, but significantly higher maximum quadriceps force (1510 N vs. 1585 N, P = 0.006) as well as the subsequent trochlear replacement showed an additional increase (1801 N, P = 0.008). However, for both replacements no significant difference to the untreated condition could be detected in mid-flexion (10-50°). When considering a bi-compartimental replacement an increase of required maximum quadriceps force needed to extend the knee has to keep in mind. However, the close to physiological movement in mid-flexion suggests that patients with a bi-crutiate retaining arthroplasty might have an advantage in knee stability compared to total knee arthroplasty. Copyright © 2013 Elsevier Ltd. All rights reserved.
Taking care of your new knee joint
Knee arthroplasty - precautions; Knee replacement - precautions ... After you have knee replacement surgery , you will need to be careful about how you move your knee, especially for the first few ...
Revision of Unicondylar to Total Knee Arthroplasty: A Systematic Review
Siddiqui, Nashat A; Ahmad, Zafar M
2012-01-01
Isolated unicompartmental osteoarthritis in the young patient is a difficult problem to treat; they may be too young to consider total knee arthroplasty due to difficulties with inevitable future revision. Unicompartmental knee arthroplasty is one possible solution as it is perceived by some as being a smaller surgical insult than total knee arthroplasty, with easier revision to total knee arthroplasty than a revision total knee arthroplasty. A total knee arthroplasty performed as a revision unicondylar knee arthroplasty is thought by some authors to have equivalent functional outcomes to a primary total knee replacement. However, there have been several studies suggesting that revision is not as simple as suggested, and that function is not as good as primary total knee arthroplasty. We performed a systematic review of the literature regarding outcomes after revision of a unicondylar knee arthroplasty. Although there are many studies proposing selective use of the unicondylar knee arthroplasty, there are a number of studies highlighting difficulties with revision and poorer outcomes, and, therefore, the unicondylar knee arthroplasty cannot be considered a small procedure that will 'buy time' for the patient, and have results equal to a primary knee arthroplasty when revised. Further controlled studies, ideally randomised, are required before final conclusions can be drawn. PMID:22905072
Well-fixed acetabular component retention or replacement: the whys and the wherefores.
Blaha, J David
2002-06-01
Occasionally the adult reconstructive surgeon is faced with a well-fixed acetabular component that is associated with an arthroplasty problem that ordinarily would require removal and replacement of the cup. Removal of a well-fixed cup is associated with considerable morbidity in bone loss, particularly in the medial wall of the acetabulum. In such a situation, retention of the cup with exchange only of the polyethylene liner may be possible. As preparation for a prospective study, I informally reviewed my experience of cup retention or replacement in revision total hip arthroplasty. An algorithm for retaining or revising a well-fixed acetabular component is presented here. Copyright 2002, Elsevier Science (USA).
Bayona, Carlos Eduardo Afanador; Somerson, Jeremy S; Matsen, Frederick A
2018-02-01
National registries are valuable tools for understanding the results of shoulder arthroplasty across populations. These databases provide an unselected view of shoulder joint replacement within geographical areas that cannot be obtained from case series or prospective studies. They can be particularly helpful in determining which diagnoses, patients, procedures, and prostheses have higher than expected rates of revision. In an attempt to determine the generalizability of registry data, we asked, 'how similar are the patients and procedures among the different national registries?' We analyzed national shoulder arthroplasty registries and databases accessed via Internet portals and through a PubMed literature search. Seven national/regional registries and five publications regarding national shoulder arthroplasty data were identified; these sources contained a combined total of 261,484 shoulder arthroplasty cases. The percentages of hemiarthroplasty, anatomic (aTSA) and reverse total shoulders (rTSA), the diagnoses leading to arthroplasty, the mean patient age, and the distribution of patient gender varied significantly among these different databases. This study indicates that the indications for and application of shoulder arthroplasty have important geographical variations and that these variations must be considered when comparing outcomes of shoulder arthroplasty from different locations. Without controlling for age, gender, diagnosis and procedure type, the results from one national registry may not be applicable to patients from a different location. In that national data provide the opportunity to reduce costs by identifying implants and procedures with higher failure rates, the funding of registries needs to be free of conflicts of interest.
Birrell, F.; Johnell, O.; Silman, A.
1999-01-01
OBJECTIVES—To estimate the requirement for total hip replacement in the United Kingdom over the next three decades METHODS—Projection of age and sex specific hip replacements in the UK over 10 year intervals taking account of demographic change and the extrapolation of arthroplasty rates from Sweden; a country with recently introduced guidelines. RESULTS—Assuming no change in the age and sex specific arthroplasty rates, the estimated number of hip replacements will increase by 40% over the next 30 year period because of demographic change alone. The proportionate change will be substantially higher in men (51%) than women (33%), with a doubling of the number of male hip replacements in those aged over 85. Changes in the threshold for surgery may increase this further—up to double the current number. CONCLUSION—A sharp rise in hip replacements will be needed to satisfy needs in the UK population over the next 30 years. PMID:10460191
Advances in Patellofemoral Arthroplasty.
Strickland, Sabrina M; Bird, Mackenzie L; Christ, Alexander B
2018-06-01
To describe current indications, implants, economic benefits, comparison to TKA, and functional and patient-reported outcomes of patellofemoral arthroplasty. Modern onlay implants and improved patient selection have allowed for recent improvements in short- and long-term outcomes after patellofemoral joint replacement surgery. Patellofemoral arthroplasty has become an increasingly utilized technique for the successful treatment of isolated patellofemoral arthritis. Advances in patient selection, implant design, and surgical technique have resulted in improved performance and longevity of these implants. Although short- and mid-term data for modern patellofemoral arthroplasties appear promising, further long-term clinical studies are needed to evaluate how new designs and technologies will affect patient outcomes and long-term implant performance.
[Juvenile rheumatoid diseases: Endoprosthetic care of destroyed hip joints].
Rehart, S; Henniger, M
2015-07-01
Patients with juvenile idiopathic arthritis (JIA) often suffer from involvement of the hip joints, with joint destruction and related functional limitations, making hip replacement necessary. To discover what special features are to be expected in patients with JIA and hip arthroplasty and what impact they have on surgical indication, choice of implant, and technique. Selective literature review and evaluation of our patient population. Compared with osteoarthritis patients, JIA patients are on average much younger at the time of hip replacement. Owing to the onset of the disease in childhood or adolescence and the frequent glucocorticoid therapy, growth disorders or abnormal anatomical findings are common in these patients. Bone density is often reduced at an early age. The perioperative management of medication has to be planned. Special implants for patients with rheumatic diseases do not exist, but the above peculiarities of this group of patients should be considered for surgical procedure and choice of implant and material. Overall, the results of hip arthroplasty in juvenile rheumatic diseases, in terms of pain relief and functional improvement, are good. The limited life of the arthroplasty is problematic. By relieving pain, improvement of the range of motion and activity level very high patient satisfaction is usually achieved by hip arthroplasty in JIA patients. In the case of involvement of the contralateral hip or the ipsilateral knee joint it may be useful to perform a simultaneous, single-stage joint replacement of both joints.
Total elbow arthroplasty in primary osteoarthritis of the elbow.
Kozak, T K; Adams, R A; Morrey, B F
1998-10-01
Primary osteoarthritis of the elbow is an infrequent condition typically managed by some form of debridement. There is no comment in the literature regarding prosthetic replacement for this condition. We report 5 patients (mean age, 68), with a minimum assessment of 3 years (range, 37-125 years) after total elbow arthroplasty. Complications in 4 patients included subluxation, fracture of a humeral component with particulate synovitis, heterotopic ossification, recurrent osteophyte formation, and transient ulnar neuropathy. Although revision was required in 2 of the 5, currently all experience had satisfactory outcomes. While replacement has proven ultimately to be a successful option for this high-demand patient group because of the high complication rate, we do not recommend replacement unless alternate operative options are deemed unacceptable.
Gandhi, Anup A; Kode, Swathi; DeVries, Nicole A; Grosland, Nicole M; Smucker, Joseph D; Fredericks, Douglas C
2015-10-15
A biomechanical study comparing arthroplasty with fusion using human cadaveric C2-T1 spines. To compare the kinematics of the cervical spine after arthroplasty and fusion using single level, 2 level and hybrid constructs. Previous studies have shown that spinal levels adjacent to a fusion experience increased motion and higher stress which may lead to adjacent segment disc degeneration. Cervical arthroplasty achieves similar decompression but preserves the motion at the operated level, potentially decreasing the occurrence of adjacent segment disc degeneration. 11 specimens (C2-T1) were divided into 2 groups (BRYAN and PRESTIGE LP). The specimens were tested in the following order; intact, single level total disc replacement (TDR) at C5-C6, 2-level TDR at C5-C6-C7, fusion at C5-C6 and TDR at C6-C7 (Hybrid construct), and lastly a 2-level fusion. The intact specimens were tested up to a moment of 2.0 Nm. After each surgical intervention, the specimens were loaded until the primary motion (C2-T1) matched the motion of the respective intact state (hybrid control). An arthroplasty preserved motion at the implanted level and maintained normal motion at the nonoperative levels. Arthrodesis resulted in a significant decrease in motion at the fused level and an increase in motion at the unfused levels. In the hybrid construct, the TDR adjacent to fusion preserved motion at the arthroplasty level, thereby reducing the demand on the other levels. Cervical disc arthroplasty with both the BRYAN and PRESTIGE LP discs not only preserved the motion at the operated level, but also maintained the normal motion at the adjacent levels. Under simulated physiologic loading, the motion patterns of the spine with the BRYAN or PRESTIGE LP disc were very similar and were closer than fusion to the intact motion pattern. An adjacent segment disc replacement is biomechanically favorable to a fusion in the presence of a pre-existing fusion.
Polyethylene Wear in Retrieved Reverse Total Shoulder Components
Day, Judd S; MacDonald, Daniel W; Olsen, Madeline; Getz, Charles; Williams, Gerald R; Kurtz, Steven M
2011-01-01
Background Reverse total shoulder arthroplasty has been used to treat rotator cuff tear arthropathy, proximal humeral fractures and for failed conventional total shoulder prostheses. It has been suggested that polyethylene wear is potentially higher in reverse shoulder replacements than in conventional shoulder replacements. The modes and degree of polyethylene wear have not been completely elucidated. The purpose of this study was to evaluate polyethylene wear patterns in seven specimens retrieved at revision arthroplasty and identify factors that may be associated with increased wear. Methods Reverse total shoulder components were retrieved from 7 patients during revision arthroplasty for loosening and/or pain. Pre-operative glenoid tilt and placement, and scapular notching were evaluated using pre-operative radiographs. Polyethylene wear was evaluated using microCT and optical microscopy. Results Wear on the rim of the polyethylene humeral cup, was identified on all retrieved components. The extent of rim wear varied from a penetration depth of 0.1 to 4.7 mm. We could not demonstrate a correlation between scapular notching and rim wear. However, rim wear was more extensive when the inferior screw had made contact with the liner. Metal on metal wear between the humeral component and the inferior screw of one component was also observed. Wear of the intended bearing surface was minimal. Discussion Rim damage was the predominant cause of polyethylene wear in our retrieved specimens. Direct contact between the humeral component and inferior metaglene screws is concerning because this could lead to accelerated UHMWPE wear and also induce mechanical loosening of the glenoid component. PMID:21724419
Chess, David G.; Grainger, R. Wayne; Phillips, Tom; Zarzour, Zane D.; Sheppard, Bruce R.
1996-01-01
Objective To review the clinical performance of the anatomic medullary locking (AML) femoral stem in total hip arthroplasty. Design A clinical and radiographic review. Setting A tertiary lower limb joint replacement centre. Patients Two hundred and twenty-one patients with noninflammatory gonarthrosis. Interventions Two hundred and twenty-seven primary total hip arthroplasties with the noncemented AML component completed by two surgeons. Main Outcome Measures Independent review by two experienced reviewers of the postoperative Harris hip score, radiographs of component fixation, size and degree of diaphyseal fill. Results Harris hip score was 84 (range from 43 to 98); component fixation showed bone ingrowth in 41%, stable fixation with fibrous ingrowth in 56% and unstable fixation in 3%; severe thigh pain in 4% of cases correlated with unstable fixation, and there was mild thigh pain in 20% of cases. Conclusion The AML femoral stem performs well in replacement arthroplasty compared with other noncemented stems. PMID:8857987
The John Charnley Award Paper. The role of joint fluid in the tribology of total joint arthroplasty.
Mazzucco, Daniel; Spector, Myron
2004-12-01
The effect of joint fluid on the tribology (ie, lubrication, friction, and wear) of total hip arthroplasty has not yet been investigated adequately. In the current study, a friction assay was used to assess four hypotheses relating to the effect of human joint fluid and its principal components on the articulation of metal-on-polyethylene. First, joint fluid was found to produce a widely varying amount of friction between cobalt-chromium and polyethylene; this range exceeded the range produced when the articulation was lubricated by water or bovine serum. Second, it was shown that hyaluronic acid, phospholipid, albumin, and gamma-globulin were not acting as boundary lubricants, but that one or more other proteins (as yet unidentified) were responsible for reducing friction in this couple. Third, lower friction was found when oxidized zirconium alloy replaced cobalt-chromium as a bearing surface on polyethylene. Finally, a pilot study suggested that lubricin, which contributes to cartilage-on-cartilage lubrication, is not a protein responsible for the tribological variabiation found among joint fluid samples. The current study showed that joint fluid is a patient factor that influences the tribology of metal-on-polyethylene arthroplasty.
2016-01-01
The aim of this study was to examine the incidence and trends of clinically relevant venous thromboembolism (VTE) including deep vein thrombosis (DVT) and pulmonary embolism (PE) after hip and knee replacement arthroplasty (HKRA) in Korea. Between January 1 and December 31, 2010, 22,127 hip replacement arthroplasty (HRA) patients and 52,882 knee replacement arthroplasty (KRA) patients were enrolled in the analysis using the administrative claims database of the Health Insurance Review and Assessment Service (HIRA). All available parameters including procedure history and clinically relevant VTE during the 90 days after HKRA were identified based on diagnostic and electronic data interchange (EDI) codes. The overall incidence of VTE, DVT, and PE during the 90 days was 3.9% (n=853), 2.7% (n=597), and 1.5% (n=327) after HRA, while the incidence was 3.8% (n=1,990), 3.2% (n=1,699), and 0.7% (n=355) after KRA. The incidence of VTE after HKRA was significantly higher in patients who had previous VTE history (odds ratio [OR], 10.8 after HRA, OR, 8.5 after KRA), chronic heart failure (2.1, 1.3), arrhythmia (1.8, 1.7), and atrial fibrillation (3.4, 2.1) than in patients who did not. The VTE incidence in patients with chemoprophylaxis was higher than that in patients without chemoprophylaxis. The incidence of VTEs revealed in this retrospective review was not low compared with the results of the studies targeting other Asian or Caucasian populations. It may warrant routine prevention including employment of chemoprophylaxis. However, the limitation of the reviewed data mandates large scale prospective investigation to affirm this observation. PMID:26770042
Yoon, Byung-Ho; Lee, Kyung-Hag; Noh, Serae; Ha, Yong-Chan; Lee, Young-Kyun; Koo, Kyung-Hoi
2013-12-01
Concerns of patients on sexual activity after total hip arthroplasty have not been well studied in Asian patients. This study aimed to determine the following: (1) what are the concerns of patients related to sexual activity after total hip arthroplasty? (2) what are the changes in sexual activity after total hip replacement in Korean patients? Details of sexual activity and concerns were obtained using a questionnaire designed specifically for the study. The questionnaire was administered to 64 patients in a face-to-face interview at an outpatient clinic. Preoperatively, 53.1% of patients experienced difficulties, primarily due to hip pathology and limitations of motion. The median time to the resumption of sexual activity was 3 months postoperatively, and most patients had no increase in the frequency of sexual activity after the total hip replacement. In 39.1% of patients were seen having difficulties with leg positioning following total hip replacement, and they were likely to change coital positions. The most common concern regarding sexual activity of patients was the fear of dislocation. Furthermore, patients with a higher stress level had lower satisfaction rates. Most patients were unable to obtain information on sexual activity following the total hip arthroplasty, and they did not consult with a physician due to the private nature of the topic. Dislocation was the most common concern of patients during sexual activity following a total hip arthroplasty, and a higher stress level was found to be associated with a lower satisfaction rate. Because most patients were unprepared to consult a physician, the provision of appropriate information before a consultation might be beneficial.
Yoon, Byung-Ho; Lee, Kyung-Hag; Noh, Serae; Ha, Yong-Chan; Koo, Kyung-Hoi
2013-01-01
Background Concerns of patients on sexual activity after total hip arthroplasty have not been well studied in Asian patients. This study aimed to determine the following: (1) what are the concerns of patients related to sexual activity after total hip arthroplasty? (2) what are the changes in sexual activity after total hip replacement in Korean patients? Methods Details of sexual activity and concerns were obtained using a questionnaire designed specifically for the study. The questionnaire was administered to 64 patients in a face-to-face interview at an outpatient clinic. Results Preoperatively, 53.1% of patients experienced difficulties, primarily due to hip pathology and limitations of motion. The median time to the resumption of sexual activity was 3 months postoperatively, and most patients had no increase in the frequency of sexual activity after the total hip replacement. In 39.1% of patients were seen having difficulties with leg positioning following total hip replacement, and they were likely to change coital positions. The most common concern regarding sexual activity of patients was the fear of dislocation. Furthermore, patients with a higher stress level had lower satisfaction rates. Most patients were unable to obtain information on sexual activity following the total hip arthroplasty, and they did not consult with a physician due to the private nature of the topic. Conclusions Dislocation was the most common concern of patients during sexual activity following a total hip arthroplasty, and a higher stress level was found to be associated with a lower satisfaction rate. Because most patients were unprepared to consult a physician, the provision of appropriate information before a consultation might be beneficial. PMID:24340146
[Clinical study on patellar replacement in total knee arthroplasty].
Bao, Liang; Gao, Zhihui; Shi, Xiaoqiang; Fang, Xiaomin; Jin, Qunhua
2013-01-01
To evaluate the influence of patellar replacement on total knee arthroplasty by comparing with non patellar replacement. Between September 2010 and November 2010, 63 patients (63 knees) with osteoarthritis who met the selection criteria and underwent total knee arthroplasty, were randomly divided into 2 groups: patellar replacement in 32 cases (replacement group), non patellar replacement in 31 cases (non patellar replacement group). There was no significant difference in gender, age, disease duration, osteoarthritis grading, the clinical and functional scores of American Knee Society Score (KSS), the patellar tilt angle, tibiofemoral angle, and patellar ligament ratio between 2 groups (P > 0.05), they were comparable. After 6 weeks, 3, 6, and 12 months of operation, clinical and imaging evaluation methods were used to assessment the effectiveness. Primary healing of incision was obtained in all patients of 2 groups. Deep venous thrombosis occurred in 6 cases of replacement group and in 8 cases of non patellar replacement group. All patients were followed up 12 months. The postoperative incidence of anterior knee pain in replacement group was significantly lower than that in non patellar replacement group (P < 0.05) at 3, 6, and 12 months after operation. No significant difference was found in the postoperative KSS clinical score between 2 groups at each time point (P > 0.05). The joint function score of the replacement group was significantly higher than that of the non patellar replacement group at the other time point (P < 0.05) except the score at 6 weeks and 3 months. Significant difference was found in the patella score between 2 groups at 12 months (P < 0.05), but no significant difference at the other time points (P > 0.05). X-ray film showed no patellar fracture and dislocation, or loosening and breakage of internal fixation. At 12 months after operation, the tibiofemoral angle, the patellar ligament ratio, and the patellar tilt angle showed no significant difference between 2 groups (P > 0.05). Patella replacement can improve knee function score and the patella score, and reduce the incidence of postoperative anterior knee pain.
Cervical disc arthroplasty: Pros and cons.
Moatz, Bradley; Tortolani, P Justin
2012-01-01
Cervical disc arthroplasty has emerged as a promising potential alternative to anterior cervical discectomy and fusion (ACDF) in appropriately selected patients. Despite a history of excellent outcomes after ACDF, the question as to whether a fusion leads to adjacent segment degeneration remains unanswered. Numerous US investigational device exemption trials comparing cervical arthroplasty to fusion have been conducted to answer this question. This study reviews the current research regarding cervical athroplasty, and emphasizes both the pros and cons of arthroplasty as compared with ACDF. Early clinical outcomes show that cervical arthroplasty is as effective as the standard ACDF. However, this new technology is also associated with an expanding list of novel complications. Although there is no definitive evidence that cervical disc replacement reduces the incidence of adjacent segment degeneration, it does show other advantages; for example, faster return to work, and reduced need for postoperative bracing.
Paschos, Nikolaos K
2015-01-01
In this article, a concise description of the recent advances in the field of osteoarthritis management is presented. The main focus is to highlight the most promising techniques that emerge in both biological joint replacement and artificial joint arthroplasty. A critical view of high quality evidence regarding outcome and safety profile of these techniques is presented. The potential role of kinematically aligned total knee replacement, navigation, and robotic-assisted surgery is outlined. A critical description of both primary and stem cell-based therapies, the cell homing theory, the use of biologic factors and recent advancements in tissue engineering and regenerative medicine is provided. Based on the current evidence, some thoughts on a realistic approach towards answering these questions are attempted. PMID:26495242
Dempsey, Kate E; Riggio, Marcello P; Lennon, Alan; Hannah, Victoria E; Ramage, Gordon; Allan, David; Bagg, Jeremy
2007-01-01
It has been postulated that bacteria attached to the surface of prosthetic hip joints can cause localised inflammation, resulting in failure of the replacement joint. However, diagnosis of infection is difficult with traditional microbiological culture methods, and evidence exists that highly fastidious or non-cultivable organisms have a role in implant infections. The purpose of this study was to use culture and culture-independent methods to detect the bacteria present on the surface of prosthetic hip joints removed during revision arthroplasties. Ten consecutive revisions were performed by two surgeons, which were all clinically and radiologically loose. Five of the hip replacement revision surgeries were performed because of clinical infections and five because of aseptic loosening. Preoperative and perioperative specimens were obtained from each patient and subjected to routine microbiological culture. The prostheses removed from each patient were subjected to mild ultrasonication to dislodge adherent bacteria, followed by aerobic and anaerobic microbiological culture. Bacterial DNA was extracted from each sonicate and the 16S rRNA gene was amplified with the universal primer pair 27f/1387r. All 10 specimens were positive for the presence of bacteria by both culture and PCR. PCR products were then cloned, organised into groups by RFLP analysis and one clone from each group was sequenced. Bacteria were identified by comparison of the 16S rRNA gene sequences obtained with those deposited in public access sequence databases. A total of 512 clones were analysed by RFLP analysis, of which 118 were sequenced. Culture methods identified species from the genera Leifsonia (54.3%), Staphylococcus (21.7%), Proteus (8.7%), Brevundimonas (6.5%), Salibacillus (4.3%), Methylobacterium (2.2%) and Zimmermannella (2.2%). Molecular detection methods identified a more diverse microflora. The predominant genus detected was Lysobacter, representing 312 (60.9%) of 512 clones analysed. In all, 28 phylotypes were identified: Lysobacter enzymogenes was the most abundant phylotype (31.4%), followed by Lysobacter sp. C3 (28.3%), gamma proteobacterium N4-7 (6.6%), Methylobacterium SM4 (4.7%) and Staphylococcus epidermidis (4.7%); 36 clones (7.0%) represented uncultivable phylotypes. We conclude that a diverse range of bacterial species are found within biofilms on the surface of clinically infected and non-infected prosthetic hip joints removed during revision arthroplasties. PMID:17501992
[Eleven-Year Experience with Total Ankle Arthroplasty].
Popelka, S; Sosna, A; Vavřík, P; Jahoda, D; Barták, V; Landor, I
2016-01-01
PURPOSE OF THE STUDY Total joint replacement is one of the options in surgical treatment of advanced ankle arthritis. It allows the ankle to remain mobile but, unfortunately, it does not provide the same longevity as total knee or hip replacements. Therefore, decisions concerning the kind of treatment are very individual and depend on the clinical status and opinion of each patient. MATERIAL AND METHODS A total of 132 total ankle replacements were carried out in the period from 2004 to 2015. The prostheses used included the Ankle Evolutive System (AES) in 52 patients, Mobility Total Ankle System (DePuy) in 24 patients and, recently, Rebalance Total Ankle Replacement implant in 53 patients. Three patients allergic to metal received the Taric prosthesis. Revision arthroplasty using the Hintegra prosthesis was carried out in four patients. The outcome of arthroplasty was evaluated on the American Orthopaedic Foot and Ankle Society (AOFAS) scoring scale. Indications for total ankle arthroplasty included post-traumatic arthritis in 83 patients, rheumatoid arthritis in 37 and primary arthritis in 12 patients. There were 78 women and 54 men, with an average age of 55.6 years at the time of surgery. RESULTS The average follow-up was 6.1 years (1-11 years). The average AOFAS score of the whole group increased from 33.2 before surgery to 82.5 after it. The primary indication had an important role. Arthroplasty outcomes were poorer in patients with post-traumatic arthritis than in those with rheumatoid arthritis or primary arthritis. In patients with post-traumatic arthritis, the average AOFAS score rose to 78.6 due to restricted motion of the ankle, and some patients continued to have pain when walking. The average AOFAS score in a total of 49 patients who had rheumatoid arthritis or primary arthritis reached a value of 86.4. Post-operative complications were recorded in ten patients (7.6%) in whom part of the wound was healing by second intention. Ossification was also a frequent complication and had to be removed in six patients (4.5%). No early infection was recorded and late infection was treated in three patients. The prosthesis had to be removed and ankle arthrodesis performed in seven patients (5.3%). All had necrosis of the talus with ankle instability. In five, the retrograde nail Medin was used and extensive defects remaining after talar necrosis were filled with massive bone grafts obtained from a bone bank. One patient required tibio-calcaneal arthrodesis with external fixator; surgery in one case involved the use of a Zimmer Trabecular Metal Ankle Fusion Spacer with retrograde nail fixation. The development of cystic radiolucencies adjacent to tibial or talar components presents another post-operative complication. It was recorded mostly in the patients after AES implantation, in whom eight of 52 (15.3%) had these findings. DISCUSSION Total ankle arthroplasty is a complicated surgical procedure potentially associated with various technical problems. The occurrence of complications is indirectly related to the experience of the orthopaedist performing surgery; literature data show that the number of complication decreases with an increased frequency of ankle replacements done. CONCLUSIONS Total ankle arthroplasty, as every orthopaedic surgery, has its advantages and disadvantages. The positive aspects are pain relief and improved mobility of the ankle allowing for physiological gait. However, it shows a lower survivorship rate that the other large joint replacements. A successful outcome depends on the correct indication. The ankle should be stable, the talus without signs of necrosis and valgus or varus deviations of the ankle should not exceed 10 to 15 degrees. total ankle arthroplasty, re-implantation, aseptic loosening, retrograde nail, Trabecular Metal spacer, revision arthroplasty.
Current and innovative pain management techniques in total knee arthroplasty.
Dalury, David F; Lieberman, Jay R; Macdonald, Steven J
2012-01-01
Pain management is a major concern for patients contemplating total knee replacement surgery and is one of the leading causes of dissatisfaction after knee replacement. Substantial progress has been made over the past several years in improving pain control after total knee replacement using multimodal pain control, preemptive analgesia, and periarticular injections.
Merolla, Giovanni; Tartarone, Antonio; Porcellini, Giuseppe
2016-01-01
Objectives: To obtain outcomes data on anatomical and reverse total shoulder arthroplasty by analysis of clinical scores and standard radiographs. Subject selection and enrollment: 400 consecutive series of patients replaced with anatomical and reverse total shoulder arthroplasty (minimum 3 years follow-up). Study Design: retrospective monocenter. Preoperative assessment: Demographics, clinical scores (Constant-Murley) as available, shoulder X-ray (AP, outlet and axillary views) . Last follow-up: Postoperative radiographhs and clinical scores. Adverse events and complications to be reported as occurred since implantation. Statistical analysis: Data collected will be summarized and analyzed for statistical significance. PMID:27326389
The Top 50 most-cited articles on Total Ankle Arthroplasty: A bibliometric analysis.
Malik, Azeem Tariq; Noordin, Shahryar
2018-03-29
Total Ankle Arthroplasty (TAA) is a relatively new and evolving field in Foot and Ankle surgery. We conducted a citation analysis to identify the characteristics of the top 50 most cited articles on total ankle arthroplasty. Using the Web of Science database and the search strategy total ankle arthroplasty OR total ankle replacement , we identified 2445 articles. After filtering for relevant articles, the top 50 cited articles on total ankle arthroplasty were retrieved for descriptive and statistical analysis. The publication years ranged from 1979 to 2013. USA was the most productive country in terms of research output, followed by the UK. Though citation analysis has its flaws, this is a comprehensive list of the top 50 articles significantly impacting literature on total ankle arthroplasty. Based on our study, we conclude that there is marked deficiency of high level articles with respect to the number of citations and future researches need to cater to this question to produce high quality studies.
Lee, Byoung-Joo; Kyung, Hee-Soo; Yoon, Seong-Dae
2015-09-01
The purpose of this study was to determine the degree of infection control and postoperative function for new articulating metal-on-cement spacer. A retrospective study of 19 patients (20 cases), who underwent a two-stage revision arthroplasty using mobile cement prosthesis, were followed for a minimum of 2 years. This series consisted of 16 women and 3 men, having an overall mean age of 71 years. During the first stage of revision, the femoral implant and all the adherent cement was removed, after which it was autoclaved before replacement. The tibial component was removed and a doughy state, antibiotic-impregnated cement was inserted on the tibial side. To achieve joint congruency, intraoperative molding was performed by flexing and extending the knee joint. Each patient was evaluated clinically and radiologically. The clinical assessments included range of motion, and the patients were scored as per the Hospital for Special Surgery (HSS) and Knee Society (KS) criteria. The mean range of knee joint motion was 70° prior to the first stage operation and 72° prior to the second stage revision arthroplasty; following revision arthroplasty, it was 113° at the final follow-up. The mean HSS score and KS knee and function scores were 86, 82, and 54, respectively, at the final follow-up. The success rate in terms of infection eradication was 95% (19/20 knees). No patient experienced soft tissue contracture requiring a quadriceps snip. This novel technique provides excellent radiological and clinical outcomes. It offers a high surface area of antibiotic-impregnated cement, a good range of motion between first and second stage revision surgery for the treatment of chronic infection after total knee arthroplasty, and is of a reasonable cost.
Wu, Ting-Kui; Meng, Yang; Wang, Bei-Yu; Hong, Ying; Rong, Xin; Ding, Chen; Chen, Hua; Liu, Hao
2018-04-27
Hybrid surgery (HS), consisting of cervical disc arthroplasty (CDA) at the mobile level, along with anterior cervical discectomy and fusion at the spondylotic level, could be a promising treatment for patients with multilevel cervical degenerative disc disease (DDD). An advantage of this technique is that it uses an optimal procedure according to the status of each level. However, information is lacking regarding the influence of the relative location of the replacement and the fusion segment in vivo. We conducted the present study to investigate whether the location of the fusion affected the behavior of the disc replacement and adjacent segments in HS in vivo. This is an observational study. The numbers of patients in the arthroplasty-fusion (AF) and fusion-arthroplasty (FA) groups were 51 and 24, respectively. The Japanese Orthopedic Association (JOA), Neck Disability Index (NDI), and Visual Analog Scale (VAS) scores were evaluated. Global and segmental lordosis, the range of motion (ROM) of C2-C7, and the operated and adjacent segments were measured. Fusion rate and radiological changes at adjacent levels were observed. Between January 2010 and July 2016, 75 patients with cervical DDD at two contiguous levels undergoing a two-level HS were retrospectively reviewed. The patients were divided into AF and FA groups according to the locations of the disc replacement. Clinical outcomes were evaluated according to the JOA, NDI, and VAS scores. Radiological parameters, including global and segmental lordosis, the ROM of C2-C7, the operated and adjacent segments, and complications, were also evaluated. Although the JOA, NDI, and VAS scores were improved in both the AF and the FA groups, no significant differences were found between the two groups at any follow-up point. Both groups maintained cervical lordosis, but no difference was found between the groups. Segmental lordosis at the fusion segment was significantly improved postoperatively (p<.001), whereas it was maintained at the arthroplasty segment. The ROM of C2-C7 was significantly decreased in both groups postoperatively (AF p=.001, FA p=.014), but no difference was found between the groups. The FA group exhibited a non-significant improvement in ROM at the arthroplasty segment. The ROM adjacent to the arthroplasty segment was increased, although not significantly, whereas the ROM adjacent to the fusion segment was significantly improved after surgery in both groups (p<.001). Fusion was achieved in all patients. No significant difference in complications was found between the groups. In HS, cephalic or caudal fusion segments to the arthroplasty segment did not affect the clinical outcomes and the behavior of CDA. However, the ROM of adjacent segments was affected by the location of the fusion segment; segments adjacent to fusion segments had greater ROMs than segments adjacent to arthroplasty segments. Copyright © 2018 Elsevier Inc. All rights reserved.
Cervical disc arthroplasty: Pros and cons
Moatz, Bradley; Tortolani, P. Justin
2012-01-01
Background: Cervical disc arthroplasty has emerged as a promising potential alternative to anterior cervical discectomy and fusion (ACDF) in appropriately selected patients. Despite a history of excellent outcomes after ACDF, the question as to whether a fusion leads to adjacent segment degeneration remains unanswered. Numerous US investigational device exemption trials comparing cervical arthroplasty to fusion have been conducted to answer this question. Methods: This study reviews the current research regarding cervical athroplasty, and emphasizes both the pros and cons of arthroplasty as compared with ACDF. Results: Early clinical outcomes show that cervical arthroplasty is as effective as the standard ACDF. However, this new technology is also associated with an expanding list of novel complications. Conclusion: Although there is no definitive evidence that cervical disc replacement reduces the incidence of adjacent segment degeneration, it does show other advantages; for example, faster return to work, and reduced need for postoperative bracing. PMID:22905327
Computer Assisted Surgery and Current Trends in Orthopaedics Research and Total Joint Replacements
NASA Astrophysics Data System (ADS)
Amirouche, Farid
2008-06-01
Musculoskeletal research has brought about revolutionary changes in our ability to perform high precision surgery in joint replacement procedures. Recent advances in computer assisted surgery as well better materials have lead to reduced wear and greatly enhanced the quality of life of patients. The new surgical techniques to reduce the size of the incision and damage to underlying structures have been the primary advance toward this goal. These new techniques are known as MIS or Minimally Invasive Surgery. Total hip and knee Arthoplasties are at all time high reaching 1.2 million surgeries per year in the USA. Primary joint failures are usually due to osteoarthristis, rheumatoid arthritis, osteocronis and other inflammatory arthritis conditions. The methods for THR and TKA are critical to initial stability and longevity of the prostheses. This research aims at understanding the fundamental mechanics of the joint Arthoplasty and providing an insight into current challenges in patient specific fitting, fixing, and stability. Both experimental and analytical work will be presented. We will examine Cementless total hip arthroplasty success in the last 10 years and how computer assisted navigation is playing in the follow up studies. Cementless total hip arthroplasty attains permanent fixation by the ingrowth of bone into a porous coated surface. Loosening of an ingrown total hip arthroplasty occurs as a result of osteolysis of the periprosthetic bone and degradation of the bone prosthetic interface. The osteolytic process occurs as a result of polyethylene wear particles produced by the metal polyethylene articulation of the prosthesis. The total hip arthroplasty is a congruent joint and the submicron wear particles produced are phagocytized by macrophages initiating an inflammatory cascade. This cascade produces cytokines ultimately implicated in osteolysis. Resulting bone loss both on the acetabular and femoral sides eventually leads to component instability. As patients are living longer and total hip arthroplasty is performed in younger patients the risks of osteolysis associated with cumulative wear is increased. Computer-assisted surgery is based on sensing feedback; vision and imaging that help surgeons align the patient's joints during total knee or hip replacement with a degree of accuracy not possible with the naked eye. For the first time, the computer feedback is essential for ligament balancing and longevity of the implants. The computers navigation systems also help surgeons to use smaller incisions instead of the traditional larger openings. Small-incision surgery offers the potential for faster recovery, less bleeding and less pain for patients. The development of SESCAN imaging technique to create a patient based model of a 3D joint will be presented to show the effective solution of complex geometry of joints.
Dissociation of modular total hip arthroplasty at the neck-stem interface without dislocation.
Kouzelis, A; Georgiou, C S; Megas, P
2012-12-01
Modular femoral and acetabular components are now widely used, but only a few complications related to the modularity itself have been reported. We describe a case of dissociation of the modular total hip arthroplasty (THA) at the femoral neck-stem interface during walking. The possible causes of this dissociation are discussed. Successful treatment was provided with surgical revision and replacement of the modular neck components. Surgeons who use modular components in hip arthroplasties should be aware of possible early complications in which the modularity of the prostheses is the major factor of failure.
Day-case surgery for total hip and knee replacement: How safe and effective is it?
Lazic, Stefan; Boughton, Oliver; Kellett, Catherine F; Kader, Deiary F; Villet, Loïc; Rivière, Charles
2018-04-01
Multimodal protocols for pain control, blood loss management and thromboprophylaxis have been shown to benefit patients by being more effective and as safe (fewer iatrogenic complications) as conventional protocols.Proper patient selection and education, multimodal protocols and a well-defined clinical pathway are all key for successful day-case arthroplasty.By potentially being more effective, cheaper than and as safe as inpatient arthroplasty, day-case arthroplasty might be beneficial for patients and healthcare systems. Cite this article: EFORT Open Rev 2018;3:130-135. DOI: 10.1302/2058-5241.3.170031.
Focal hypermobility observed in cervical arthroplasty with Mobi-C.
Kerferd, Jack William; Abi-Hanna, David; Phan, Kevin; Rao, Prashanth; Mobbs, Ralph J
2017-12-01
In recent decades cervical arthroplasty, or cervical disc replacement, has been steadily increasing in popularity as a procedure for the treatment of degenerative pathologies of the cervical spine. This is based on an evolving body of literature that documents superior outcomes in cervical disc replacement over fusion, for both single and double level pathologies, in well selected patients. One of the more recent and popular implants currently on the market is the Mobi-C cervical artificial disc (LDR Medical; Troyes, France). In this paper we report on two cases where focal hypermobility was observed following total disc replacement using the Mobi-C cervical artificial disc. This is followed by a discussion as to potential contributing factors to this hypermobility in relation to both implant design, and operative technique, suggesting potential changes that might prevent this in future patients.
One Stage Conversion of an Infected Fused Knee to Total Knee Replacement - A Surgical Challenge
Ravikumar, Mukartihal; Kendoff, Daniel; Citak, Mustafa; Luck, Stefan; Gehrke, Thorsten; Zahar, Akos
2013-01-01
Background and Purpose: Two-stage revision arthroplasty is a common technique for the treatment of infected total knee replacement. Few reports have addressed the conversion of a fused knee into a total knee replacement. However, there is no case reported of converting an infected fused knee into a hinge knee using a one-stage procedure. Methods: We report on a 51-year old male patient with an infected fused knee after multiple surgeries. Results and Interpretation: A one-stage conversion of septic fused knee into total knee arthroplasty by a rotational hinge prosthesis was performed. The case highlights that with profound preoperative assessment, meticulous surgical technique, combined antibiotic treatment and the right implant, one-stage revision in a surgical challenge may have a role as a treatment option with good functional outcome. PMID:23526706
[Minimally invasive approaches to hip and knee joints for total joint replacement].
Rittmeister, M; König, D P; Eysel, P; Kerschbaumer, F
2004-11-01
The manuscript features the different minimally invasive approaches to the hip for joint replacement. These include medial, anterior, anterolateral, and posterior approaches. The concept of minimally invasive hip arthroplasty makes sense if it is an integral part of a larger concept to lower postoperative morbidity. Besides minimal soft tissue trauma, this concept involves preoperative patient education, preemptive analgesia, and postoperative physiotherapy. It is our belief that minimal incision techniques for the hip are not suited for all patients and all surgeons. The different minimally invasive approaches to the knee joint for implantation of a knee arthroplasty are described and discussed. There have been no studies published yet that fulfill EBM criteria. The data so far show that minimally invasive approaches and implantation techniques for total knee replacements lead to quicker rehabilitation of patients.
Post-treatment glenoid classification system for total shoulder arthroplasty.
Churchill, R Sean
2012-04-01
Over the past 10 years, numerous advancements in glenoid preparation and resurfacing have occurred. Current glenoid classification systems are either focused solely on the patient's preoperative glenoid bone configuration or on the available glenoid bone stock in revision arthroplasty cases. While these systems provide value in preoperative planning, they fail to properly classify the surgical reconstruction completed. A literature review of common bone preparation methods and sources of glenoid prosthetic failure was performed. Based upon this review, a classification system for grading the status of the glenoid after prosthetic implantation was developed. A 6 category, post-treatment, glenoid classification system is proposed: type 0: no reaming; type I: glenoid reaming into but not through the subchondral bone; type II: glenoid reaming which perforates through <50% of the subchondral bone surface area; type III: glenoid reaming which perforates through >50% of the subchondral bone surface area; type IV: use of structural bone graft; and type V: use of a posterior augmented glenoid prosthesis. Types I-III are further subdivided into subtype A which have 100% bone support of the prosthesis, and subtype B which have a region of unsupported prosthesis. The classification system proposed addresses the surgical management of the glenoid during prosthetic replacement. This unique approach to classifying the glenoid following surgical intervention will allow direct follow-up comparison of similarly treated glenoid replacements. Future multicenter studies, possibly through joint registry databases, could then determine the long-term efficacy of the various glenoid preparation methods. Copyright © 2012 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.
Long-term outcome of total hip arthroplasty in patients with haemophilia.
Strauss, A C; Rommelspacher, Y; Nouri, B; Bornemann, R; Wimmer, M D; Oldenburg, J; Pennekamp, P H; Schmolders, J
2017-01-01
Besides the target joints (elbow, knee and ankle), the hip is one of the commonly affected joints in haemophilic arthropathy. Hip arthroplasty is the therapy of choice after failure of conservative treatment. There are only limited data on long-term results after primary total hip arthroplasty (THA). The aim of this retrospective study was to analyse clinical outcome and complication rate after total hip replacement in patients with severe haemophilic arthropathy. Forty-three patients with haemophilia (PWH), one patient with von Willebrand disease and one patient with a Factor-VII-deficiency undergoing 49 total hip arthroplasties, were evaluated in a retrospective study. Harris hip score (HHS), range of motion (ROM), pain status (visual analogue scale, VAS) complication rate and patient satisfaction were assessed at a mean follow-up of 11.5 years (range: 3-32). HSS, ROM and VAS improved significantly combined with high patient satisfaction. In total, three (6.1%) periprosthetic infections and five (10.2%) aseptic implant loosenings occurred after THA leading to revision arthroplasty. In two (4.1%) cases, a pseudotumour and one (2.0%) periarticular ossification had to be resected after THA. Total hip replacement in PWH leads to a significant increase of function, reduction of pain and a high satisfaction. Due to the relatively high complication rate (infections and aseptic loosening) compared to patients without haemophilia, an individual assessment of the risk-benefit ratio from surgical and haemostaseological point of view is needed. © 2016 John Wiley & Sons Ltd.
Smith, Toby O; Latham, Sarah; Maskrey, Vivienne; Blyth, Annie
2015-09-01
It has been perceived that people following total hip arthroplasty (THA) or total knee arthroplasty (TKA) have the capability, with reduced pain, to increase their levels of physical activity. To determine the attitudes and perceptions of people awaiting or having undergone THA or TKA to physical activity post-arthroplasty and to identify potential facilitators or barriers to engage in active living and physical activity pursuits. Systematic review of published and unpublished databases was undertaken from their inception to November 2014. Studies exploring the attitudes and perceptions of people awaiting or having undergone THA or TKA to physical activity post-arthroplasty were included. Data were analysed through a meta-ethnography approach. From 528 citations, 13 papers were eligible, sampling 282 people post-THA or TKA. The literature was judged moderate to high quality. Following THA and TKA, people either wished to return to their pre-pathology level of physical activity or simply be able to engage in less physically demanding activities that are meaningful to them and their lifestyles. Barriers to engaging in higher levels of physical activity were largely related to limited information, which culminated in fear surrounding 'doing the right thing' both for individual's recovery and the longevity of the joint replacement. While many people post-THA or TKA wish to return to pre-pathological physical activity status, there is limited interest in actually undertaking greater levels of physical activity post-arthroplasty either for pleasure or health gains. Improvement in education and awareness of this may be key drivers to improve habitualisation of physical activity post-arthroplasty. CRD42014014995. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Chu, Janet N; Maselli, Judith; Auerbach, Andrew D; Fang, Margaret C
2017-07-01
Recent guidelines include aspirin as an option to prevent venous thromboembolism (VTE) in selected patients undergoing hip or knee replacement surgery. However, the efficacy of aspirin after arthroplasty has not been well-defined, particularly in more contemporary patient populations. We compared rates of post-operative VTE between patients who received aspirin-only versus anticoagulants after hip or knee arthroplasty, using data from a large US-based administrative database. We conducted a retrospective cohort study of 231,780 adults who underwent total knee arthroplasty and 110,621 who underwent total hip arthroplasty in 2009-2012 and who received pharmacologic VTE prophylaxis (aspirin or anticoagulant) within the first 7days after surgery. We compared the risk of post-operative VTE between patients receiving aspirin-only vs. anticoagulants, controlling for clinical and hospital characteristics using multivariable logistic regression with propensity score adjustment. Aspirin-only prophylaxis was administered to 7.5% of patients after knee arthroplasty and 8.0% after hip arthroplasty. Post-operative VTE was diagnosed in 2217 (0.96%) patients after knee arthroplasty and 454 (0.41%) after hip arthroplasty. Compared to anticoagulants, aspirin was not associated with a higher risk for post-operative VTE either after knee arthroplasty (adjusted odds ratio and 95% confidence interval [OR] 0.34 [0.24-0.48]) or hip arthroplasty (OR 0.82 [0.45-1.51]). Aspirin was uncommonly administered as the sole prophylactic agent after hip or knee arthroplasty in this study. However, patients who received aspirin-only had similar rates of post-operative VTE compared to patients who received anticoagulants. Further research should focus on distinguishing which patients benefit more from anticoagulants versus aspirin after arthroplasty. Copyright © 2017 Elsevier Ltd. All rights reserved.
Senay, Andréa; Trottier, Milanne; Delisle, Josée; Banica, Andreea; Benoit, Benoit; Laflamme, G Yves; Malo, Michel; Nguyen, Hai; Ranger, Pierre; Fernandes, Julio C
2018-01-01
Low-molecular-weight heparin (LMWH) is a recommended anticoagulant for thromboprophylaxis after major orthopedic surgery. Dabigatran etexilate is an oral anticoagulant recognized as noninferior to LMWH. We aimed to assess the incidence of symptomatic venous thromboembolic events (VTEs) after discharge in patients who underwent joint replacement, using a hospital registry. Patients who underwent total knee and hip arthroplasty between September 2011 and March 2015 were selected. Subcutaneous enoxaparin (30 mg twice daily) was given during hospitalization. At discharge, patients received either enoxaparin 30 mg twice daily/40 mg once daily or dabigatran 220 mg/150 mg once daily. Patients were seen or called at 2, 6, and 12 weeks after surgery. Outcomes were the number of VTEs, including deep venous thrombosis, pulmonary embolism, and the number of major/minor bleeding events after discharge. After discharge, 1468 patients were prescribed enoxaparin and 904 dabigatran (1396 total knee arthroplasty and 976 total hip arthroplasty patients). Mean age was 66±10 years, and 60% were female. The cumulative incidence of VTEs during the 12-week follow-up was 0.7%. One patient sustained a VTE during the switch window. Seven patients sustained a pulmonary embolism (0.3%). There was no statistical difference between the total knee arthroplasty and total hip arthroplasty groups. The incidence of major and minor bleeding events during follow-up was 0.3% and 30.3%, respectively. These events had a higher incidence in the dabigatran group compared to the enoxaparin group after discharge ( p <0.05), but not between knee and hip replacement groups for major bleeding events. A pharmaceutical prophylaxis protocol using LMWH and dabigatran during the post-discharge period resulted in low incidences of VTE and equivalence between treatments. However, the increased number of major and minor bleeding events in patients taking dabigatran is of concern regarding the safety and needs to be evaluated using analyses adjusted for risk factors.
Gheorghiu, Daniel; Peter, Viju; Lynch, Martin
2010-02-01
The teflon hip arthroplasty design was used by Sir John Charnley in the early 60's but was taken off the market due to high complication rates. A case is reported of an intrapelvic granuloma after total hip arthroplasty following the use of a teflon socket. This appears to be the last surviving patient treated by Sir John Charnley using a Teflon hip socket design.
Brewster, Mark; McArthur, John; Mauffrey, Cyril; Lewis, Andrew Charles; Hull, Peter; Ramos, James
2010-01-01
We report the functional results of a case series of Moje first metatarsophalangeal total joint replacements carried out between February 2001 and November 2006. All patients who underwent Moje arthroplasty under the care of a single surgeon were included; outcome scores and complications were recorded annually. A total of 32 joints in 29 consecutive patients were followed for a mean duration of 34 (range 6 to 74) months, and the mean patient age at the time of operation was 56 (range 38 to 79) years. Hallux rigidus was the primary diagnosis in 28 (87.5%) of the cases. The mean American Orthopaedic Foot & Ankle Society Hallux-Metatarsophalangeal-Interphalangeal score at final follow-up was 74/100 (range 9 to 100), with 13 (40.63%) joints rated good to excellent. Two (6.25%) joints were revised to arthrodesis at a mean of 52 (range 41 to 63) months following the arthroplasty procedure, and the overall prevalence of postoperative complications was 6 (18.75%). Based on these results, we concluded that first MTPJ total joint replacement with the Moje device remains promising, but still has room for improvement before the results match those obtained with larger joint (knee, hip) arthroplasty. Copyright 2010 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.
[Detection of metal ions in hair after metal-metal hip arthroplasty].
Hernandez-Vaquero, D; Rodríguez de la Flor, M; Fernandez-Carreira, J M; Sariego-Muñiz, C
2014-01-01
There is an increase in the levels of metals in the serum and urine after the implantation of some models of metal-metal hip prosthesis. It has recently been demonstrated that there is an association between these levels and the levels found in hair. The aim of this study is to determine the presence of metals in hair, and to find out whether these change over time or with the removal of the implant. The levels of chromium, cobalt and molybdenum were determined in the hair of 45 patients at 3, 4, 5, and 6 years after a hip surface replacement. The mean age was 57.5 years, and two were female. Further surgery was required to remove the replacement and implant a new model with metal-polyethylene friction in 11 patients, 5 of them due to metallosis and a periarticular cyst. The mean levels of metals in hair were chromium 163.27 ppm, cobalt 61.98 ppm, and molybdenum 31.36 ppm, much higher than the levels found in the general population. A decrease in the levels of chromium (43.8%), molybdenum (51.1%), and cobalt (91.1%) was observed at one year in the patients who had further surgery to remove the prosthesis. High concentrations of metals in the hair are observed in hip replacements with metal-metal friction, which decrease when that implant is removed. The determination of metal ions in hair could be a good marker of the metal poisoning that occurs in these arthroplasty models. Copyright © 2014 SECOT. Published by Elsevier Espana. All rights reserved.
Clinical Biomechanics of Wear in Total Hip Arthroplasty
Callaghan, John J; Pedersen, Douglas R; Johnston, Richard C; Brown, Thomas D
2003-01-01
Complementary clinical and laboratory studies were performed to identify variables associated with polyethylene wear following total hip replacement, and to elucidate the mechanisms responsible for accelerated wear in the total hip arthroplasty construct. Observational cohort studies were performed using a prospective clinical database of more than 4000 consecutive primary total hip arthroplasties performed by a single surgeon, to identify wear-related variables. These variables included head size, acetabular/femoral component impingement, and third body debris. Novel digital edge detection techniques were developed and employed to accurately measure wear, and to determine the relationships of head size and third body debris to acceleration of wear. A novel slidingdistance-coupled finite element model was formulated and employed to examine the mechanisms responsible for wear. The long-term cohort studies demonstrated smaller head sizes to be associated with less wear. Third body debris generated from cable fretting was associated with an increase in wear, osteolysis, and acetabular loosening, especially with larger head sizes. The sliding-distance-coupled finite element model replicated the wear rates occurring in vitro and in vivo, demonstrating the importance of sliding distance on polyethylene wear following total hip arthroplasty. It also demonstrated substantial increases in wear associated with femoral head scratching from third body debris. Further extension of the finite element formulation demonstrated the potential for acetabular component rim damage from impingement wear, and the enhanced potential for third body ingress to the bearing surface with larger head sizes. Edge detection wear measurement techniques demonstrated that early wear rates were predictive of long-term wear rates. These complementary clinical and laboratory investigations have provided insight into 1) the significance of sliding distance and physiologic loci of motion as contributing factors in minimizing wear, 2) the deleterious effects of third body particulates in accelerating wear, 3) the potential for, and factors related to, impingement wear, and 4) the potential advantages and compromises related to the use of larger head sizes in the bearing surface construct. PMID:14575243
Hannibal, Matthew; Thomas, Derek J; Low, Jeffrey; Hsu, Ken Y; Zucherman, James
2007-10-01
This is a retrospective analysis of data that was collected prospectively from 2 concurrent FDA IDE lumbar arthroplasty clinical trials performed at a single center. To determine if there is a clinical difference between the 1-level ProDisc patients versus the 2-level ProDisc patients at a minimum of 2 years of follow-up. Marnay's work with ProDisc I prompted the U.S. Clinical Trials of the ProDisc II under the direction of the FDA. Disc replacement surgery in the United States has shown promising results for all types of prostheses up to 6 months. Marnay and colleagues showed that their results at 10 years were still promising, and they saw no significant difference between 1-level and multilevel disc replacements. The findings of Ipsen and colleagues suggest that multilevel arthroplasty cases may be less successful than disc replacement at a single level. Patients were part of the FDA clinical trial for the Prodisc II versus circumferential fusion study at a single institution. We identified 27 patients who received ProDisc at 1 level and 32 who received it at 2 levels with at least a 2-year follow-up, for a total of 59 patients. Unpaired t tests were performed on the mean results of Visual Analog Scale, Oswestry Disability Index, SF-36 Healthy Survey Physical Component Summary, and satisfaction using 10-cm line visual scale scores to determine a clinical difference if any between the 2 populations. While patients receiving ProDisc at 2 levels scored marginally lower in all evaluation indexes, score differences in each category were also found to hold no statistical significance. This study was unable to identify a statistically significant difference in outcome between 1- and 2-level ProDisc arthroplasty patients in a cohort from a single center. The equality of clinical effectiveness between 1- and 2-level ProDisc has yet to be determined.
[Arthrodesis following revision of a knee endoprosthesis. Literature review 1984-1994].
Kohn, D; Schmolke, S
1996-04-01
Two percent of primary and 8% of revision total knee replacements are followed by arthrodesis. Today knee arthrodesis is the most important salvage procedure after failed total knee arthroplasty, resection arthroplasty and above-the-knee amputation being the only alternatives. Analysis of the literature between 1984 and 1994 revealed 533 cases treated with arthrodesis of the knee; 403 were done after failed total knee arthroplasty. The fusion rate was 74%. External fixation, intramedullary nail, plates and combinations of these are currently used for fixation. The literature and an analysis of our own patients from 1988 to 1994 showed that arthrodesis after failed arthroplasty is a difficult procedure, and complications often occur. Bone loss of the distal femur and proximal tibia is the one most important prognostic factor. A new classification system for bone loss is presented.
Clamp, Jonathan A; Baiju, Dean; Copas, David P; Hutchinson, James W; Rowles, John M
2008-09-01
The introduction of Modernising Medical Careers (MMC) is likely to reduce specialist registrar (SpR) operative experience during higher surgical training (HST). A further negative impact on training by local Independent Sector Treatment Centres (ISTCs) could reduce experience, and thus competence, in primary joint arthroplasty at completion of higher surgical training. Retrospective case note and radiograph analysis of patients receiving primary hip and knee arthroplasty in a teaching hospital, before and after the establishment of a local ISTC. Patients and operative details were recorded from the selected case notes. Corresponding radiographs were assessed and the severity of the disease process assessed. Fewer primary hip and knee replacements were performed by SpRs in the time period after the establishment of an ISTC. ISTCs may adversely affect SpR training in primary joint arthroplasty.
Contemporary Strategies for Rapid Recovery Total Hip Arthroplasty.
Stambough, Jeffrey B; Beaulé, Paul E; Nunley, Ryan M; Clohisy, John
2016-01-01
Over the past several years, rapid recovery protocols for total hip arthroplasty have evolved in parallel with advancements in pain management, regional anesthesia, focused rehabilitation, and the patient selection process. As fiscal pressures from payers of health care increase, surgical outcomes and complications are being scrutinized, which evokes a sense of urgency for arthroplasty surgeons as well as hospitals. The implementation of successful accelerated recovery pathways for total hip arthroplasty requires the coordinated efforts of surgeons, practice administrators, anesthesiologists, nurses, physical and occupational therapists, case managers, and postacute care providers. To optimize performance outcomes, it is important for surgeons to select patients who are eligible for rapid recovery. The fundamental tenets of multimodal pain control, regional anesthesia, prudent perioperative blood management, venous thromboembolic prophylaxis, and early ambulation and mobility should be collectively addressed for all patients who undergo primary total hip replacement.
Rožanković, Marjan; Marasanov, Sergej M; Vukić, Miroslav
2017-06-01
Prospective randomized study. To compare the clinical outcome after Discover arthroplasty versus anterior cervical discectomy and fusion (ACDF) in patients treated for symptomatic single-level cervical disk disease. ACDF is still the gold standard for surgical treatment of cervical spine degenerative disk disease. However, results of many studies suggest that it may cause degenerative changes at levels immediately above and below the fusion, known as adjacent segment degenerative disease. Cervical arthroplasty has recently been introduced as an alternative to standard procedure of ACDF. It showed decreased surgical morbidity, decreased complications from postoperative immobilization, and an earlier return to previous level of function. A total of 105 consecutive patients with single-level cervical disk disease, producing radiculopathy and/or myelopathy were randomly divided into groups to undergo ACDF or Discover arthroplasty. All patients were evaluated with preoperative and postoperative serial radiographic studies and clinically, using Neck Disability Index, Visual Analog Scale and neurological status at 3, 6, 12, and 24 months. The results of our study indicate that cervical arthroplasty using Discover Artificial Cervical Disc provides favorable clinical and radiologic outcomes in a follow-up period of 24 months. There has been significant improvement in clinical parameters, Visual Analog Scale and Neck Disability Index, at 3, 6, 12, and 24 months in arthroplasty group comparing to control group. The Discover artificial cervical disc replacement offers favorable outcome compared with ACDF for a single-level cervical disk disease at short-term and long-term follow-up.
Use of Kinesiology Taping in Rehabilitation after Knee Arthroplasty: a Randomised Clinical Study.
Woźniak-Czekierda, Weronika; Woźniak, Kamil; Hadamus, Anna; Białoszewski, Dariusz
2017-10-31
Proprioception and body balance after knee arthroplasty have a considerable impact on restoration of joint function and a normal gait pattern. Kinesiology Taping (KT) is a method that may be able to influence these factors. The aim of this study was to assess the effects of KT application on sensorimotor efficiency, balance and gait in patients undergoing rehabili-ta--tion after knee replacement surgery. The study involved 120 male and female patients (mean age was 69 years) after total knee repla-cement. The patients were randomly assigned to one of two groups: Experimental Group (n=51) and Control Group (n=60). Both groups underwent standard rehabilitation lasting 20 days. In addition, the Experimental Group received KT applications. Treat-ment outcomes were assessed based on tests evaluating balance, joint position sense and functional gait performance, conducted both before and after the therapy. Statistically significant improvements were noted across all the parameters assessed in the Experimental Group (p<0.005). Significant improvements were also seen in the Control Group (p<0.005), but, in percentage terms, the improvement was higher in the Experimental Group. The only exception was the right/left foot load distribution, whose symmetry improved proportionally in both groups. 1. Patients after knee replacement surgery have considerable proprioception deficits, impaired body balance and reduced functional performance, which may increase the risk of falls in this group of patients. 2. Both standard physiotherapy and combination therapy with Kinesiology Taping (modified by the present authors) used in patients after knee arthroplasty may considerably improve the level of proprioception, body balance and overall functional performance. 3. The technique of dynamic taping proposed in this paper may optimise standard physiotherapy used in patients after knee arthroplasty and increase its clinical efficacy. Further studies are required.
Ghomrawi, Hassan M.; Eggman, Ashley A.; Pearle, Andrew D.
2015-01-01
Background: Trade-offs between upfront benefits and later risk of revision of unicompartmental knee arthroplasty compared with those of total knee arthroplasty are poorly understood. The purpose of our study was to compare the cost-effectiveness of unicompartmental knee arthroplasty with that of total knee arthroplasty across the age spectrum of patients undergoing knee replacement. Methods: Using a Markov decision analytic model, we compared unicompartmental knee arthroplasty with total knee arthroplasty with regard to lifetime costs, quality-adjusted life-years (QALYs), and incremental cost-effectiveness ratios (ICERs) from a societal perspective for patients undergoing surgery at forty-five, fifty-five, sixty-five, seventy-five, or eighty-five years of age. Transition probabilities were estimated from the literature; survival, from the Swedish Knee Arthroplasty Register; and costs, from the literature and the Healthcare Cost and Utilization Project (HCUP) database. Costs and QALYs were discounted at 3.0% annually. We conducted sensitivity analyses to test the robustness of model estimates and threshold analyses. Results: For patients sixty-five years of age and older, unicompartmental knee arthroplasty dominated total knee arthroplasty, with lower lifetime costs and higher QALYs. Unicompartmental knee arthroplasty was no longer cost-effective at a $100,000/QALY threshold when total knee arthroplasty rehabilitation costs were reduced by two-thirds or more for these older patients. Lifetime societal savings from utilizing unicompartmental knee arthroplasty in all older patients (sixty-five or older) in 2015 and 2020 were $56 to $336 million and $84 to $544 million, respectively. In the forty-five and fifty-five-year-old age cohorts, total knee arthroplasty had an ICER of $30,300/QALY and $63,000/QALY, respectively. Unicompartmental knee arthroplasty became cost-effective when its twenty-year revision rate dropped from 27.8% to 25.7% for the forty-five-year age group and from 27.9% to 26.7% for the fifty-five-year age group. Conclusions: Unicompartmental knee arthroplasty is an economically attractive alternative in patients sixty-five years of age or older, and modest improvements in implant survivorship could make it a cost-effective alternative in younger patients. PMID:25740030
Sabatini, L; Schirò, M; Atzori, F; Ferrero, G; Massè, A
2016-01-01
Isolated patellofemoral (PF) arthritis is rare, and there is no complete agreement about the best surgical treatment. The operative treatments are total knee arthroplasty and patellofemoral replacement (PFR). The incidence of many early complications of PF arthroplasty has decreased with the introduction of newer designs. Nowadays, the main cause of revision surgery is the progression of tibiofemoral osteoarthritis. In the past, PF arthroplasty was contraindicated in patients with evidence of osteoarthritis or pain in medial or lateral tibiofemoral compartments. The improvement in implant designs and surgical techniques has allowed the addition of a monocompartmental arthroplasty for the medial or lateral tibiofemoral compartment. In this work, we evaluate our first experience with PF arthroplasty and its combination with unicompartmental knee arthroplasty. From May 2014 to March 2016, we treated 14 patients. An isolated PF arthroplasty was performed in six knees (five patients), and a combined PF and unicompartmental knee arthroplasty was performed in nine cases. We observed a significant improvement in the clinical and functional Knee Society Scores (KSSs) after surgery in our patients. We obtained good results in our cases both for clinical and functional KSSs. Patellar clunk was recorded in one case. We are going toward a new attitude in which partial osteoarthritic changes could be treated with partial resurfacing prosthetic solutions such as unicompartmental, bi-unicompartmental or PFR alone, or unicompartmental combined, which respects the cruciates and achieves maximal bone preservation, which is vital, particularly, for young patients.
Historical view and future demand for knee arthroplasty in Sweden
Rolfson, Ola; W-Dahl, Annette; Garellick, Göran; Sundberg, Martin; Kärrholm, Johan; Robertsson, Otto
2015-01-01
Background and purpose The incidence of knee osteoarthritis will most likely increase. We analyzed historical trends in the incidence of knee arthroplasty in Sweden between 1975 and 2013, in order to be able to provide projections of future demand. Patients and methods We obtained information on all knee arthroplasties in Sweden in the period 1975–2013 from the Swedish Knee Arthroplasty Register, and used public domain data from Statistics Sweden on the evolution of and forecasts for the Swedish population. We forecast the incidence, presuming the existence of a maximum incidence. Results We found that the incidence of knee arthroplasty will continue to increase until a projected upper incidence level of about 469 total knee replacements per 105 Swedish residents aged 40 years and older is reached around the year 2130. In 2020, the estimated incidence of total knee arthroplasties per 105 Swedish residents aged 40 years and older will be 334 (95% prediction interval (PI): 281–374) and in 2030 it will be 382 (PI: 308–441). Using officially forecast population growth data, around 17,500 operations would be expected to be performed in 2020 and around 21,700 would be expected to be performed in 2030. Interpretation Today’s levels of knee arthroplasty are well below the expected maximum incidence, and we expect a continued annual increase in the total number of knee arthroplasties performed. PMID:25806653
Summer, Burkhard; Paul, Carina; Mazoochian, Farhad; Rau, Christoph; Thomsen, Marc; Banke, Ingo; Gollwitzer, Hans; Dietrich, Karin-Almut; Mayer-Wagner, Susanne; Ruzicka, Thomas; Thomas, Peter
2010-07-01
Some nickel (Ni) allergic patients develop complications following Ni-containing arthroplasty. In the peri-implant tissue of such patients, we had observed lymphocyte dominated inflammation together with IFN-gamma and IL-17 expression. To determine whether Ni stimulation of peripheral blood mononuclear cells (PBMCs) of such patients would lead to a different cytokine pattern as compared to Ni-allergic patients with symptom-free arthroplasty. Based on history and patch testing in 15 Ni-allergic patients (five without implant, five with symptom-free arthroplasty, five with complicated arthroplasty) and five non-allergic individuals, lymphocyte transformation test (LTT) was performed using PBMC. In parallel in vitro cytokine response to Ni was assessed by real-time reverse transcriptase-polymerase chain reaction (RT-PCR). All 15 Ni-allergic individuals showed enhanced LTT reactivity to Ni (mean SI = 8.42 +/- 1.8) compared to the non-allergic control group. Predominant IFN-gamma expression to Ni was found both in the five allergic patients without arthroplasty and also in the five allergic, symptom-free arthroplasty patients. In contrast, in the five Ni-allergic patients with arthroplasty-linked complications a predominant, significant IL-17 expression to Ni was seen but not in patients with symptom-free arthroplasty. The predominant IL-17 type response to Ni may characterize a subgroup of Ni-allergic patients prone to develop lymphocytic peri-implant hyper-reactivity.
Tang, Xiao-Bo; Dong, Pei-Long; Wang, Jian
2014-04-01
To compare therapeutic effects between patella replacement and patella osteotomy in total knee arthroplasty. From April 2004 to April 2011, 52 patients (54 knees) were enrolled in the clinical trail of total knee arthroplasty, who received patella replacement (24 knees, including 13 males and 11 females,ranging in age from 53 to 78 years old or patella osteotomy (30 knees,including 16 males and 12 females,ranging in age from 55 to 79 years old. The average follow-up period was 56 months,ranging from 20 to 80 months. The American HSS Score for knee, the Feller score for patella, range of motion (ROM) for knee, patient satisfaction and complications related to the patella were used to evaluate therapeutic effects. In the patella replacement group,the preoperative and final follow-up HSS scores of patients were 38.4 +/- 8.2 and 91.2 +/- 8.6 respectively; Feller scores were 13.6 +/- 6.2 and 25.2 +/- 4.2; scores of anterior knee pain were 3.9 +/- 3.2 and 11.2 +/- 3.7; ROM were (78 +/- 26) degrees and(108 +/- 18) degrees. In the patella osteotomy group,the preoperative and final follow-up HSS scores of patients were 39.5 +/- 8.4 and 91.0 +/- 8.5 respectively;Feller scores were 13.4 +/- 6.5 and 25.6 +/- 4.0; scores of anterior knee pain were 3.7 +/- 3.1 and 11.3 +/- 3.6; ROM were (76 +/- 27) degrees and (110 +/- 19) degrees. In the patella replacement group,patient's satisfaction was 91%, and complication related to the patella was 16.7%; in the patella osteotomy group, patient's satisfaction was 89%, and complications related to the patella was 10.0%. There were no statistically significant differeneces in final follow-up HSS scores, Feller scores, scores of anterior knee pain and ROM between the two groups. However,there was no significant difference of patient's satisfaction between them. There was statistically significant differenece of patella-related complications between the two groups, and the complication rate in the patella replacement group was higher than that in the patella osteotomy group. Total knee arthroplasty with patella replacement or patella osteotomy dramatically relieves pain and improves the knee function. Patella-related complications are associated with its treatment methods, but post-operative anterior knee pain and patient's satisfaction are not related to treatment methods of the patella.
The economics of new age arthroplasty: can we afford it?
Sculco, Thomas P
2010-09-07
New technology in joint replacement design and materials adds cost that must be documented by improved outcomes. This is not always the case as the recent metal/metal data has shown. The current economics of arthroplasty have put increasing financial pressure on hospitals and will progress under new health care legislation. New technology must be cost-effective and this will be increasingly difficult in an era of outstanding long-term results with current designs. Cost may necessitate less expensive alternatives, eg, generic implants, in arthroplasty patients. Joint replacement surgery has evolved over the past 4 decades into a highly successful surgical procedure. Earlier designs and materials that demonstrated inferior functional and long-term results have disappeared in a Darwinian fashion. Through this evolutionary process many of the current designs have proven efficacy and durability. Current outcome data indicates that hip and knee designs demonstrate 90% to 95% success rates at 15-year follow-up. Technologic advances are necessary to improve implant design and materials, however, only in an environment of reduced reimbursement to hospitals can the increase cost be justified. Copyright 2010, SLACK Incorporated.
Cost-Effective Mobile-Based Healthcare System for Managing Total Joint Arthroplasty Follow-Up.
Bitsaki, Marina; Koutras, George; Heep, Hansjoerg; Koutras, Christos
2017-01-01
Long-term follow-up care after total joint arthroplasty is essential to evaluate hip and knee arthroplasty outcomes, to provide information to physicians and improve arthroplasty performance, and to improve patients' health condition. In this paper, we aim to improve the communication between arthroplasty patients and physicians and to reduce the cost of follow-up controls based on mobile application technologies and cloud computing. We propose a mobile-based healthcare system that provides cost-effective follow-up controls for primary arthroplasty patients through questions about symptoms in the replaced joint, questionnaires (WOMAC and SF-36v2) and the radiological examination of knee or hip joint. We also perform a cost analysis for a set of 423 patients that were treated in the University Clinic for Orthopedics in Essen-Werden. The estimation of healthcare costs shows significant cost savings (a reduction of 63.67% for readmission rate 5%) in both the University Clinic for Orthopedics in Essen-Werden and the state of North Rhine-Westphalia when the mobile-based healthcare system is applied. We propose a mHealth system to reduce the cost of follow-up assessments of arthroplasty patients through evaluation of diagnosis, self-monitoring, and regular review of their health status.
Web Page Content and Quality Assessed for Shoulder Replacement.
Matthews, John R; Harrison, Caitlyn M; Hughes, Travis M; Dezfuli, Bobby; Sheppard, Joseph
2016-01-01
The Internet has become a major source for obtaining health-related information. This study assesses and compares the quality of information available online for shoulder replacement using medical (total shoulder arthroplasty [TSA]) and nontechnical (shoulder replacement [SR]) terminology. Three evaluators reviewed 90 websites for each search term across 3 search engines (Google, Yahoo, and Bing). Websites were grouped into categories, identified as commercial or noncommercial, and evaluated with the DISCERN questionnaire. Total shoulder arthroplasty provided 53 unique sites compared to 38 websites for SR. Of the 53 TSA websites, 30% were health professional-oriented websites versus 18% of SR websites. Shoulder replacement websites provided more patient-oriented information at 48%, versus 45% of TSA websites. In total, SR websites provided 47% (42/90) noncommercial websites, with the highest number seen in Yahoo, compared with TSA at 37% (33/90), with Google providing 13 of the 33 websites (39%). Using the nonmedical terminology with Yahoo's search engine returned the most noncommercial and patient-oriented websites. However, the quality of information found online was highly variable, with most websites being unreliable and incomplete, regardless of search term.
Long-term results of bipolar arthroplasty in osteoarthritis of the hip.
Bateman, J E; Berenji, A R; Bayne, O; Greyson, N D
1990-02-01
Bipolar arthroplasty of the hip was introduced by the first author in 1974. From that time until 1988, this type of arthroplasty has been carried out in 1213 hips at the authors' institution. Included is a group of 760 osteoarthritic hips on which follow-up studies have been done at six months, five years, ten years, and 15 years. Studies of the acetabulum show healthy bone preservation as long as 15 years after surgery. A process of floor reinforcement in certain states has also been identified. The relatively simple operative technique has resulted in few postoperative complications. Clinical results as long as 15 years postsurgery compare favorably with two-piece replacement techniques.
... C, Anderson PA, eds. Skeletal Trauma: Basic Science, Management, and Reconstruction . 5th ed. Philadelphia, PA: Elsevier Saunders; 2015:chap 68. Murphy GA. Total ankle arthroplasty. In: Azar FM, Beaty JH, Canale ...
Clamp, Jonathan A; Baiju, Dean SR; Copas, David P; Hutchinson, James W; Rowles, John M
2008-01-01
INTRODUCTION The introduction of Modernising Medical Careers (MMC) is likely to reduce specialist registrar (SpR) operative experience during higher surgical training (HST). A further negative impact on training by local Independent Sector Treatment Centres (ISTCs) could reduce experience, and thus competence, in primary joint arthroplasty at completion of higher surgical training. PATIENTS AND METHODS Retrospective case note and radiograph analysis of patients receiving primary hip and knee arthroplasty in a teaching hospital, before and after the establishment of a local ISTC. Patients and operative details were recorded from the selected case notes. Corresponding radiographs were assessed and the severity of the disease process assessed. RESULTS Fewer primary hip and knee replacements were performed by SpRs in the time period after the establishment of an ISTC. Conclusions ISTCs may adversely affect SpR training in primary joint arthroplasty. PMID:18765029
Patient-specific instrumentation for total shoulder arthroplasty
Gomes, Nuno Sampaio
2016-01-01
Shoulder arthroplasty is a demanding procedure with a known complication rate. Most complications are associated with the glenoid component, a fact that has stimulated investigation into that specific component of the implant. Avoiding glenoid component malposition is very important and is a key reason for recent developments in pre-operative planning and instrumentation to minimise risk. Patient-specific instrumentation (PSI) was developed as an alternative to navigation systems, originally for total knee arthroplasty, and is a valid option for shoulder replacements today. It offers increased accuracy in the placement of the glenoid component, which improves the likelihood of an optimal outcome. A description of the method of pre-operative planning and surgical technique is presented, based on the author’s experience and a review of the current literature. Cite this article: Gomes N. Patient-specific instrumentation for total shoulder arthroplasty. EFORT Open Rev 2016;1:177-182. DOI: 10.1302/2058-5241.1.000033. PMID:28461945
Safavi-Abbasi, Sam; Reyes, Phillip M; Abjornson, Celeste; Crawford, Neil R
2016-12-01
A new experimental protocol was applied utilizing a simplified postural control model. Multiple constructs were tested nondestructively by interconnecting segmental rods to screws. To investigate how posture and distribution of segmental angles under physiological loads are affected by combined cervical arthroplasty and fusion. Previous studies of biomechanics of multilevel arthroplasty have focused on range of motion and intradiscal pressure. No previous study has investigated postural changes and segmental angle distribution. In 7 human cadaveric C3-T1 specimens, C4-C5, C5-C6, and C6-C7 disks were replaced with ProDisc-C (Synthes). Combinations of fusion (f) adjacent to arthroplasty (A) were simulated at C4-C5, C5-C6, and C6-C7, respectively: fAA, AfA, AAf, ffA, fAf, Aff, fff. C3-C4 and C7-T1 remained intact. A compressive belt apparatus simulated normal muscle cocontraction and gravitational preload; C3-C4, C4-C5, C5-C6, C6-C7, and C7-T1 motions were tracked independently. Parameters studied were segmental postural compensation, neutral buckling, and shift in sagittal plane instantaneous axis of rotation (IAR). With one or more levels unfused, the arthroplasty levels preferentially moved toward upright posture before the intact levels. Neutral buckling was greatest for 3-level arthroplasty, less for 2-level arthroplasty, and least for 1-level arthroplasty. Among the three 1-level arthroplasty groups (ffA, fAf, Aff), arthroplasty at the caudalmost level resulted in significantly greater buckling than with arthroplasty rostralmost or at mid-segment (P<0.04, analysis of variance/Holm-Sidak). Although IAR location was related to buckling, this correlation did not reach significance (P=0.112). Arthroplasty levels provide the "path of least resistance," through which the initial motion is more likely to occur. The tendency for specimens to buckle under vertical compression became greater with more arthroplasty levels. Buckling appeared more severe with arthroplasty more caudal. Buckling only moderately correlated to shifts in IAR, meaning slight malpositioning of the devices would not necessarily cause buckling.
Lungu, Eugen; Vendittoli, Pascal-André; Desmeules, François
2015-10-05
The ability to predict preoperatively the identity of patients undergoing hip arthroplasty at risk of suboptimal outcomes could help implement interventions targeted at improving surgical results. The objective was to develop a preliminary prediction algorithm (PA) allowing the identification of patients at risk of unsatisfactory outcomes one to two years following hip arthroplasty. Retrospective data on a cohort of 265 patients having undergone primary unilateral hip replacement (188 total arthroplasties and 77 resurfacing arthroplasties) from 2004 to 2010 were collected from our arthroplasty database. Hip pain and function, as measured by the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) were collected, as well as self-reported hip joint perception after surgery. Demographic and clinical variables recorded at the time of the surgery were considered as potential predictors. Patients were considered as having a suboptimal surgical outcome if they were in the worst quartile of the postoperative total WOMAC score and perceived their operated hip as artificial with minimal or major limitations. The PA was developed using recursive partitioning. Mean postoperative surgical follow-up was 446 ± 171 days. Forty patients (15.1 %) had a postoperative total WOMAC score in the worst quartile (>11.5/100) and perceived their joint as artificial with minimal or major restrictions. A PA consisting of the following variables achieved the most acceptable level of prediction: gender, age at the time of surgery, body mass index (BMI), and three items of the preoperative WOMAC (degree of pain with walking on a flat surface and during the night as well as degree of difficulty with putting socks or stockings). The rule had a sensitivity of 75.0 % (95 % CI: 59.8-85.8), a specificity of 77.8 % (95 % CI: 71.9-82.7), a positive predictive value of 37.5 % (95 % CI: 27.7-48.5), a negative predictive value of 94.6 % (95 % CI: 90.3-97.0) and positive and negative likelihood ratios of 3.38 (95 % CI: 2.49-4.57) and 0.34 (95 % CI: 0.19-0.55) respectively. The preliminary PA shows promising results at identifying patients at risk of significant functional limitations, increased pain and inadequate joint perception after hip arthroplasty. Clinical use should not be implemented before additional validation and refining.
Lactobacillus as a rare cause of an infected total knee replacement: a case report
2009-01-01
Introduction We report a rare case of an infected revision total knee replacement as a result of a Lactobacillus species infection. Lactobacillus infections have been associated with prolonged broad-spectrum antibiotic use. This can have implications in revision surgery, especially when patients have been on previous long-term suppressive antibiotic therapy. Case presentation An 81-year-old British man with a previous history of complex revision knee arthroplasty for infection presented with a hot, swollen knee joint. He had previously been on long-term suppressive antibiotic therapy. Aspiration of the knee joint yielded a culture of Lactobacillus species. Conclusion In patients undergoing revision joint arthroplasty, especially for previous infection, the presence of common and uncommon bacterial species must be excluded and eradicated before further surgical intervention. PMID:19830207
[Total hip arthroplasty through anterior "minimal invasive" approach].
Moerenhout, Kevin G; Cherix, Stéphane; Rüdiger, Hannes A
2012-12-19
Total hip replacement has seen a tremendous development and has become one of the most successful surgical interventions in orthopaedics. While during the first decades of development of total hip arthroplasty the fixation of the implant into the bone was the main concern, the focus has shifted towards surgical technique and soft tissue handling. In order to avoid permanent soft tissue damage, muscular dysfunction and concerns in regards to cosmetics, minimal invasive and anatomic approaches have been developed. We here provide a short overview on various methods of total hip replacements and we describe our technique through a minimal invasive direct anterior approach. While muscle and nerve damage is minimal, this technique allows for a rapid rehabilitation and is associated with an excellent functional outcome and a minimal risk for dislocation.
Burke, Neil G; Green, Connor; McHugh, Gavin; McGolderick, Niall; Kilcoyne, Carol; Kenny, Patrick
2012-08-01
It is important to reduce potential wound complications in total hip and total knee arthroplasty procedures. The purpose of this study was to compare the jubilee dressing method to a standard adhesive dressing. 124 patients (62 total hip replacements and 62 total knee replacements) were randomly selected to have either a standard adhesive dressing or jubilee method dressing. The number of dressing changes, incidence of blistering, leakage, appearance of inflammation, infection rate and the average stay in hospital was recorded for each patient. The jubilee dressing significantly reduced the rate of blistering, leakage and number of dressing changes when compare to a traditional adhesive dressing (p < 0.05). The rate of inflammation and average length of stay in hospital was not significantly different between the two groups. The authors recommend the use of this dressing for total hip and total knee arthroplasty procedures due to the associated lower complication rate. Copyright © 2012 Tissue Viability Society. Published by Elsevier Ltd. All rights reserved.
Mont, Michael A; McElroy, Mark J; Johnson, Aaron J; Pivec, Robert
2013-08-01
The purpose of this prospective controlled trial was to determine if efficiency increases could be achieved in non-navigated and navigated total knee arthroplasties by replacing traditional saws, cutting blocks, and trials with specialized saws and single-use cutting blocks and trials. Various timing metrics during total knee arthroplasty, including operating room preparation times and specific intra-operative times, were measured in 400 procedures performed by eight different surgeons at 6 institutions. Efficiency increases were the result of statistically significant reductions in combined instrument setup and cleanup times as well as in adjusted surgical episode times in navigated total knee arthroplasties. Single-use instruments show promising benefits, but adequate patient follow-up is needed to confirm safety and efficacy before they can be widely adopted. Nevertheless, the authors believe that the use of single-use instruments, cutting guides, and trial implants for total knee arthroplasty will play an increasing role in improving operating room efficiency. Copyright © 2013 Elsevier Inc. All rights reserved.
Cementless total knee arthroplasty
Risitano, Salvatore; Sabatini, Luigi; Giachino, Matteo; Agati, Gabriele; Massè, Alessandro
2016-01-01
Interest for uncemented total knee arthroplasty (TKA) has greatly increased in recent years. This technique, less used than cemented knee replacement in the last decades, sees a revival thanks an advance in prosthetic design, instrumentation and operative technique. The related literature in some cases shows conflicting data on survival and on the revision’s rate, but in most cases a success rate comparable to cemented TKA is reported. The optimal fixation in TKA is a subject of debate with the majority of surgeons favouring cemented fixation. PMID:27162779
2016-01-01
Total knee replacement (TKR) is a procedure used to treat knee arthropathy. Patients’ dissatisfaction is still relevant (literature reports dissatisfaction rates as high as 40%). The anterior cruciate ligament is usually removed while performing a total knee arthroplasty, thus changing knee biomechanics. As patients’ mean age to surgery is decreasing, bicruciate retaining models, which preserve normal biomechanics, may be useful in increasing patients’ outcomes. Limited data concerning bicruciate retaining arthroplasty is available; although clinical results are encouraging, there are concerns regarding surgical exposure, anterior cruciate integrity evaluation, and implant fixation. PMID:27162778
Birnbaum, Klaus; Gutknecht, Norbert
2010-07-01
The cement often left in the femur socket during hip joint revision arthroplasty is usually removed by curettage. Another method for removing the cement is to use an ultrasonic system, and yet another alternative may be to use a laser system. The aim of these investigations was to determine the pulse rate and pulse energy of the Er:YAG laser for sufficient cement ablation. We also compared the results obtained using the laser with those obtained using an ultrasonic device or curettage by histological and scanning electron microscopy (SEM) investigation of the border zone between the polymethyl methacrylate (PMMA) and unfixed specimens of femoral bone. Therefore we prepared 30 unfixed human femur stems after hip joint replacement and prepared ten sagittal sections from each femur stem (in total 300 sections). Of these 300 specimens, 180 were treated with the Er:YAG laser, 60 with the ultrasonic system and 60 by curettage. The high pulse energy of 500 mJ and a pulse rate of 4 Hz provided the highest PMMA ablation rate, although the boundary surface between PMMA and femoral bone was not as fine-grained as found in samples treated at 15 Hz and 250 mJ. However, the treatment time for the same cement ablation rate with the latter settings was twice that at 4 Hz and 500 mJ. Compared to the boundary surfaces treated with the ultrasonic device or curettage, the laser-treated samples had a more distinct undifferentiated boundary surface between PMMA and femoral bone. After development of the Er:YAG-laser to provide higher pulse energies, it may in the future be an additional efficient method for the removal of PMMA in revision arthroplasty. The Er:YAG laser should be combined with an endoscopic and a rinsing suction system so that PMMA can be removed from the femoral shaft under direct vision.
Knee and Ankle Arthroplasty in Hemophilia
Solimeno, Luigi Piero; Pasta, Gianluigi
2017-01-01
Today, major surgical procedures can be safely performed in hemophilic patients with chronic arthropathy, using available factor concentrates. In this setting, total knee replacement is considered the “gold standard”, while the use of total ankle replacement is still debated. Indeed, the unsatisfactory results obtained with the previous available design of implants did not raise enthusiasm as knee or hip replacement. Recently, the introduction of new implant designs and better reported outcomes have renewed the interest in total ankle replacement in people with hemophilia. In this review, the role of replacement surgery in the treatment of chronic hemophilic arthropathy will be described. PMID:29165342
RSA and registries: the quest for phased introduction of new implants.
Nelissen, Rob G H H; Pijls, Bart G; Kärrholm, Johan; Malchau, Henrik; Nieuwenhuijse, Marc J; Valstar, Edward R
2011-12-21
Although the overall survival of knee and hip prostheses at ten years averages 90%, recent problems with several hip and knee prostheses have illustrated that the orthopaedic community, industry, and regulators can still further improve patient safety. Given the early predictive properties of roentgen stereophotogrammetric analysis (RSA) and the meticulous follow-up of national joint registries, these two methods are ideal tools for such a phased clinical introduction. In this paper, we elaborate on the predictive power of RSA within a two-year follow-up after arthroplasty and its relationship to national joint registries. The association between RSA prosthesis-migration data and registry data is evaluated. The five-year rate of revision of RSA-tested total knee replacements was compared with that of non-RSA-tested total knee replacements. Data were extracted from the published results of the national joint registries of Sweden, Australia, and New Zealand. There was a 22% to 35% reduction in the number of revisions of RSA-tested total knee replacements as compared with non-RSA-tested total knee replacements in the national joint registries. Assuming that the total cost of total knee arthroplasty is $37,000 in the United States, a 22% to 35% reduction in the number of revisions (currently close to 55,000 annually) could lead to an estimated annual savings of over $400 million to the health-care system. The phased clinical introduction of new prostheses with two-year RSA results as a qualitative tool could lead to better patient care and could reduce the costs associated with revision total knee arthroplasty. Follow-up in registries is necessary to substantiate these results and to improve post-market surveillance.
Migration characteristics and early clinical results of the NANOS® short-stem hip arthroplasty.
Kaipel, Martin; Grabowiecki, Phillip; Sinz, Katrina; Farr, Sebastian; Sinz, Günter
2015-05-01
Femoral short stems promise essential advantages in total hip arthroplasty. Up to now, only short- and midterm clinical studies exist. Data on early stem migration that could predict later aseptic loosening at an early stage are rare. The purpose of this study was to assess migration patterns and clinical outcome 2 years after hip replacement by a metaphyseal anchored cementless short stem. Migration data and clinical results were prospectively assessed in 49 patients. Clinical outcome was measured using the Harris Hip Score (HHS). Migration analyses were performed using the computer-assisted Einzel-Bild-Roentgen-Analyse (EBRA) system. At 2 years after surgery, none of the implants needed revision, and HHS increased from 47.9 up to 98.1. Of 49 patients, 5 (10%) showed increased vertical stem migration (1.5 mm/2a) that might predict late aseptic loosening. Of 49 stems, 44 (90%) showed stable migration patterns indicating a beneficial long-term outcome. Results of this study confirm the excellent clinical data of previous works. Migration patterns strongly suggest that short-stem arthroplasty is not only an innovative but also a reliable strategy in total hip replacement.
Jansson, V; Steinbrück, A; Hassenpflug, J
2016-06-01
The German Arthroplasty Registry (EPRD) was founded in 2010 and has been in full operation since 2014. Previous attempts at a systematic data collection of elective and non-elective knee and hip replacement in Germany failed mainly because of the long-term lack of funding. The EPRD is an interdisciplinary collaborative partnership between the German Association of Orthopedics and Orthopedic Surgery (DGOOC), all implant manufacturers of the German Medical Technology Association (BVMed), health insurers (AOK and the Association of Additional Healthcare Insurance) and hospitals (German Hospital Federation). As part of this cooperation a worldwide unique implant database has been set up, which includes all relevant components and a detailed description of implant specifications. This implant library enables a detailed evaluation of implant survival, revision rates and possible inferior implant performance of knee and hip replacements in Germany. At the end of 2015 the EPRD encompassed over 200,000 registered operations. Due to the high number of hip and knee arthroplasties in Germany with many different implants from different manufacturers there will be a rapid growth of data that are available for a national and also international comparison of the results.
10-year evaluation of the cementless low-contact- stress rotating-platform total knee arthroplasty.
Efstathopoulos, Nikolaos; Mavrogenis, Andreas F; Lallos, Stergios; Nikolaou, Vassilios; Papagelopoulos, Panayiotis J; Savvidou, Olga D; Korres, Demetrios S
2009-01-01
We present the clinical and radiographic outcomes of the cementless low-contact-stress (LCS) rotating-platform total knee arthroplasty. Overall, 423 prostheses were implanted in 393 consecutive patients (30 patients had bilateral total knee replacement) for primary varus gonarthrosis (381 patients) and rheumatoid arthritis (12 patients). There were 81 men and 312 women with a mean age of 73 years (range, 58-85 years). Patella replacement was not performed in any case. Clinical and radiographic evaluation was performed using the Knee Society Score (KSS) and the Knee Society Assessment Form, respectively. The mean follow-up was 10 years (range, 5-15 years). Three patients were lost to follow-up. Survival of the prostheses was 98% at 10 years; three prostheses required revision for deep infection, bearing dislocation, and periprosthetic fracture. The mean KSS improved significantly, from 42 and 44 points preoperatively to 90 and 79 points, respectively, at the latest evaluation (P < 0.001); results were excellent in 278 cases, good in 106, fair in 27, and poor in nine. Radiolucent lines were observed in 80 cases; revision arthroplasty was not performed in any of these cases. Complications included deep infection in one patient, bearing dislocation in one, skin necrosis in four, and a supracondylar fracture in one. The cementless LCS rotating-platform total knee arthroplasty is associated with excellent mid- and long-term results for patients with osteoarthritis and rheumatoid arthritis of the knee.
Prospective study on serum metal levels in patients with metal-on-metal lumbar disc arthroplasty.
Gornet, Matthew F; Burkus, J K; Harper, M L; Chan, F W; Skipor, A K; Jacobs, J J
2013-04-01
Metal-on-metal total disc replacement is a recent alternative treatment for degenerative disc disease. Wear and corrosion of these implants can lead to local and systemic transport of metal debris. This prospective longitudinal study examined the serum chromium and cobalt levels in 24 patients with cobalt-chromium alloy metal-on-metal lumbar disc replacements. Serum was assayed for chromium (Cr) and cobalt (Co) using high-resolution inductively-coupled plasma-mass spectrometry. Detection limits were 0.015 ng/mL for Cr and 0.04 ng/mL for Co. Median serum Co levels at pre-op, 3, 6, 12, 24, and 36-months post-op were 0.10, 1.03, 0.96, 0.98, 0.67, and 0.52 ng/mL, respectively. Median serum Cr levels were 0.06, 0.49, 0.65, 0.43, 0.52, and 0.50 ng/mL, respectively. In general, these results indicated that serum Co and Cr levels are elevated at all postoperative time points and are of the same order of magnitude as those observed in well-functioning metal-on-metal surface replacements of the hip and in metal-on-metal total hip replacements at similar postoperative time points.
Goreham-Voss, Curtis M.; Hyde, Philip J.; Hall, Richard M.; Fisher, John; Brown, Thomas D.
2010-01-01
Computational simulations of wear of orthopaedic total joint replacement implants have proven to valuably complement laboratory physical simulators, for pre-clinical estimation of abrasive/adhesive wear propensity. This class of numerical formulations has primarily involved implementation of the Archard/Lancaster relationship, with local wear computed as the product of (finite element) contact stress, sliding speed, and a bearing-couple-dependent wear factor. The present study introduces an augmentation, whereby the influence of interface cross-shearing motion transverse to the prevailing molecular orientation of the polyethylene articular surface is taken into account in assigning the instantaneous local wear factor. The formulation augment is implemented within a widely-utilized commercial finite element software environment (ABAQUS). Using a contemporary metal-on-polyethylene total disc replacement (ProDisc-L) as an illustrative implant, physically validated computational results are presented to document the role of cross-shearing effects in alternative laboratory consensus testing protocols. Going forward, this formulation permits systematically accounting for cross-shear effects in parametric computational wear studies of metal-on-polyethylene joint replacements, heretofore a substantial limitation of such analyses. PMID:20399432
The trivector approach for minimally invasive total knee arthroplasty: a technical note.
Benazzo, Francesco; Rossi, Stefano Marco Paolo
2012-09-01
One of the main criticisms of minimally invasive approaches in total knee arthroplasty has been their poor adaptability in cases of major deformity or stiffness of the knee joint. When they are used in such cases, excessive soft-tissue tension is needed to provide appropriate joint exposure. Here, we describe the "mini trivector approach," which has become our standard approach for total knee replacement because it permits us to enlarge the indication for minimally or less invasive total knee replacement to many knees where quad sparing, a subvastus approach, or a mini quad or mini midvastus snip may not be sufficient to achieve correct exposure. It consists of a limited double snip of the VMO and the quadriceps tendon that reduces tension on the extensor mechanism and allows easier verticalization of the patella as well as good joint exposure.
Stemless shoulder arthroplasty: current status.
Churchill, R Sean
2014-09-01
Since the original Neer humeral replacement in the 1950s, the standard primary anatomic total shoulder arthroplasty design has slowly evolved. Most recently, the humeral stem has become progressively shorter to help combat stem-related complications. Currently, there are several companies who have developed and marketed a stemless humeral arthroplasty component. Manufacturers' data for 5 stemless shoulder arthroplasty components currently on the market were analyzed and reviewed. A literature review of short-term results for stemless shoulder arthroplasty was completed. Of the stemless shoulder arthroplasty systems available on the market, 3 are currently undergoing clinical trials in the United States. The Tornier Simpliciti (Tornier, Edina, MN, USA) clinical trial began in 2011. The study with 2-year minimum follow-up results is scheduled for completion in November 2014. The Arthrex Eclipse (Arthrex, Naples, FL, USA) clinical trial was started in January 2013. The tentative study completion date is 2017. The Biomet Nano (Biomet, Warsaw, IN, USA) clinical trial began in October 2013 and also has a tentative completion date of 2017. No other clinical trial is currently under way in the United States. Early results for stemless shoulder arthroplasty indicate clinical results similar to standard stemmed shoulder arthroplasty. Radiographic analysis indicates implant stability without migration or subsidence at 2- to 3-year minimum follow-up.. Several stemless shoulder arthroplasty implants are available outside the United States. Early clinical and radiographic results are promising, but well-designed clinical studies and midterm results are lacking. Three clinical trials are currently under way in the United States with initial availability for use anticipated in 2015. Copyright © 2014 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.
Voorde, Pia C Ten; Rasmussen, Jeppe V; Olsen, Bo S; Brorson, Stig
2015-06-01
There is no consensus on which type of shoulder prosthesis should be used in patients with rheumatoid arthritis (RA). We describe patients with RA who were treated with shoulder replacement, regarding patient-reported outcome, prosthesis survival, and causes of revision, and we compare outcome after resurfacing hemi-arthroplasty (RHA) and stemmed hemi-arthroplasty (SHA). We used data from the national Danish Shoulder Arthroplasty Registry and included patients with RA who underwent shoulder arthroplasty in Denmark between 2006 and 2010. Patient-reported outcome was obtained 1-year postoperatively using the Western Ontario Osteoarthritis of the Shoulder index (WOOS), and rates of revision were calculated by checking revisions reported until December 2011. The patient-reported outcome of RHA was compared to that of SHA using regression analysis with adjustment for age, sex, and previous surgery. During the study period, 167 patients underwent shoulder arthroplasty because of rheumatoid arthritis, 80 (48%) of whom received RHA and 34 (26%) of whom received SHA. 16 patients were treated with total stemmed shoulder arthroplasty (TSA), and 24 were treated with reverse shoulder arthroplasty (rTSA). 130 patients returned a completed questionnaire, and the total mean WOOS score was 63. The cumulative 5-year revision rate was 7%. Most revisions occurred after RHA, with a revision rate of 14%. Mean WOOS score was similar for RHA and for SHA. This study shows that shoulder arthroplasty, regardless of design, is a good option in terms of reducing pain and improving function in RA patients. The high revision rate in the RHA group suggests that other designs may offer better implant survival. However, this should be confirmed in larger studies.
Makki, D; Deierl, K; Pandit, A; Trakru, S
2014-09-01
The aim of this prospective study was to investigate the risk of contamination of surgical gloves during preparation and draping in joint replacement surgery. During 46 hip and knee replacement procedures, the gloves of orthopaedic consultants (n=5) and registrars (n=3) were assessed for contamination immediately after draping by impression of gloved fingers on blood agar. Contamination was evaluated by the surgeon's grade, the type of procedure, the role of the assistant and the dominance of the hand. A total of 125 pairs of top gloves were examined (79 pairs from registrars and 46 pairs from consultants). Bacterial contamination was isolated on 19 pairs (15.2%) (16 pairs from registrars and 3 pairs from consultants, p=0.04). Coagulase negative staphylococci were the main isolates and contamination was considered low in all cases (1-5 colonies). Contamination was seen more on the dominant hand (16 gloves from dominant hands and 6 from non-dominant hands, p=0.04), on the index finger and thumb. More contaminated gloves were seen in hip arthroplasty procedures (16 pairs from total hip replacements vs 3 pairs from total knee replacements, p=0.02). Contamination of glove fingertips during draping in joint replacement procedures is more likely to occur among junior surgeons, in hip rather than knee arthroplasty procedures and on the dominant hand. It is therefore essential that surgeons of different grades replace gloves used in draping to avoid exposing patients to the risk of infection.
Galea, V P; Laaksonen, I; Matuszak, S J; Connelly, J W; Muratoglu, O; Malchau, H
2017-04-01
Our first aim was to determine whether there are significant changes in the level of metal ions in the blood at mid-term follow-up, in patients with an Articular Surface Replacement (ASR) arthroplasty. Secondly, we sought to identify risk factors for any increases. The study involved 435 patients who underwent unilateral, metal-on-metal (MoM) hip resurfacing (HRA) or total hip arthroplasty (THA). These patients all had one measurement of the level of metal ions in the blood before seven years had passed post-operatively (early evaluation) and one after seven years had passed post-operatively (mid-term evaluation). Changes in ion levels were tested using a Wilcoxon signed-rank test. We identified subgroups at the highest risk of increase using a multivariable linear logistic regression model. There were significant increases in the levels of metal ions for patients who underwent both MoM HRA (Chromium (Cr): 0.5 parts per billion (ppb); Cobalt (Co): 1.1 ppb) and MoM THA (Cr: 0.5 ppb; Co: 0.7 ppb). In a multivariable model considering MoM HRAs, the change in the levels of metal ions was influenced by female gender (Co: Odds Ratio (OR) 1.42; p = 0.002 and Cr: OR 1.08; p = 0.006). The change was found to be irrespective of the initial level for the MoM HRAs, whereas there was a negative relationship between the initial level and the change in the level for those with a MoM THA (Co: OR -0.43; p < 0.001 and Cr: OR -0.14; p = 0.033). The levels of metal ions in the blood increase significantly over the period until mid-term follow-up in patients with both a MoM HRA and those with a MoM THA. We recommend that the levels of metal ions be measured most frequently for women with a MoM HRA. While those with a MoM THA appear to stabilise at a certain level, the accuracy of this trend is not yet clear. Vigilant follow-up is still recommended. Cite this article: Bone Joint J 2017;99-B(4 Supple B):33-40. ©2017 Galea et al.
Namdari, Surena; Milby, Andrew H; Garino, Jonathan P
2011-09-01
Multiple total knee arthroplasty revisions pose significant surgical challenges, such as bone loss and soft tissue compromise. For patients with bone loss and extensor mechanism insufficiency after total knee arthroplasty, arthrodesis is a treatment option for the avoidance of amputation. However, arthrodesis is both difficult to achieve in situations with massive bone loss and potentially undesirable due to the dramatic shortening that follows. Although intramedullary nailing for knee arthrodesis has been widely reported, this technique has traditionally relied on the achievement of bony union. We report a case of a patient with massive segmental bone loss in which a modular intercalary prosthesis was used for arthrodesis to preserve limb length without bony union. Copyright © 2011 Elsevier Inc. All rights reserved.
Bilateral total hip arthroplasty in Morquio-Brailsford's syndrome: a report of two cases.
Tassinari, Enrico; Boriani, Luca; Traina, Francesco; Dallari, Dante; Toni, Aldo; Giunti, Armando
2008-09-01
We report two cases of bilateral cementless total hip arthroplasty in two young women affected by Morquio-Brailsford syndrome. Morquio-Brailsford disease belongs to the mucopolysaccharidoses; it shows growth retardation with disproportional dwarfism. Usually patients are affected by a severe joint degeneration from their 2nd or 3rd decade. Young age, severe dysplasia, and joint size are the main technical problems for a total hip replacement. Accurate radiographic and CT planning allows the use of standard prostheses instead of custom-made ones.
Aim, Florence; Werthel, Jean-David; Deranlot, Julien; Vigan, Marie; Nourissat, Geoffroy
2018-04-01
One of the most frequent demands from patients after shoulder replacement surgery is to return to sport. To determine the rate of return to sport after shoulder arthroplasty (total shoulder arthroplasty, reverse shoulder arthroplasty, hemiarthroplasty) in recreational athletes. Meta-analysis and systematic review. The PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines were followed to perform this systematic review and meta-analysis of the results in the literature as well as the presentation of results. A search of the literature was performed in the electronic databases MEDLINE, Scopus, Embase, and the Cochrane Library. The quality of the included studies was evaluated according to the MINORS (Methodological Index for Nonrandomized Studies) score. Inclusion criteria were studies in English evaluating return to sport after shoulder replacement surgery and on patients practicing a sport regularly, whatever the level, with all ages and sports included. The main criterion was the rate of patients who returned to a sport activity. Nine studies were selected among the 35 identified, including a total of 613 patients (39% male and 61% female) with a mean age of 71.7 years (range, 22.6-92.6 years). All the included patients practiced sports before surgery. The most common reported sports were golf (n = 140), swimming (n = 128), and tennis (n = 54). The mean rate of return to sport was 80.7% (range, 57.1%-97.3%). All patients who returned to sport were practicing in the 3 months before surgery. No radiological data were reported in the literature. The subgroup analysis for resuming golf after shoulder arthroplasty revealed a rate of return to sport of 79.2% (95% CI, 62.9%-89.5%). In the swimming subgroup, the rate was 75.6% (95% CI, 61.3%-85.8%) and in the tennis subgroup was 63.5% (95% CI, 34.1%-85.5%). The subgroup analysis for reverse shoulder arthroplasty reported a lower rate of return to sport than for all types of shoulder arthroplasty combined: 76.5% (95% CI, 60%-87%) versus 80.7% (95% CI, 70.9%-87.8%), respectively. Most patients returned to sport after surgery, and all who returned to sport were practicing their sport in the 3 months before surgery. No radiological data were reported in the literature.
Volpin, Andrea; Kini, S G; Meuffels, D E
2017-03-31
There exist limited options for treatment of patients with combined medial compartment arthritis and anterior cruciate ligament (ACL) deficiency. Ideal treatment is one that offers lasting relief of symptoms not compromising any future surgery. Unicompartmental knee replacement has shown consistently good results in the relatively young and active population, but there is a high reported incidence of failure up to 20%, if performed in ACL-deficient knees. One of the recognized treatment modality is combined ACL reconstruction and unicompartmental arthroplasty. A systematic review was conducted looking at the demographics, techniques, complications and outcome of combined ACL reconstruction with unicompartmental knee arthroplasty. A systematic literature search within the online Medline, PubMed Database, EMBASE, Web of Science, Cochrane and Google Scholar was carried out until October 2016 to identify relevant articles. A study was defined eligible if it met the following inclusion criteria: the surgical procedure combined unicompartmental knee arthroplasty and anterior cruciate ligament reconstruction; patient's clinical and/or functional outcomes were reported; any complications intra-operatively and post-operatively were reported; and the full-text articles, written in English, German, Italian, Dutch or Spanish, were available. Quality and risk of bias assessments were done using standardized criteria set. A total of 8 studies met the inclusion criteria encompassing 186 patients who were treated with simultaneous ACL reconstruction and unicompartmental knee arthroplasty. The mean age was 50.5 years (range from 44 to 56) with a mean follow-up of 37.6 months (range from 24 to 60). There was an improvement in mean Oxford Score from 27.5 to 36.8. Complications reported included tibial inlay dislocation (n = 3), conversion to a total knee arthroplasty (n = 1), infection requiring two-stage revision (n = 2), deep-vein thrombosis (n = 1), stiffness requiring manipulation under anaesthesia (n = 1), retropatellar pain requiring arthroscopic adhesiolysis (n = 1). Unicompartmental knee arthroplasty combined with ACL reconstruction can be a valid treatment option for selected patients, with combined medial unicompartmental knee osteoarthritis and ACL deficiency. Systematic Review of Level IV Studies, Level IV.
The Influence Of Component Alignment On The Life Of Total Knee Prostheses
NASA Astrophysics Data System (ADS)
Bugariu, Delia; Bereteu, Liviu
2012-12-01
An arthritic knee affects the patient's life by causing pain and limiting movement. If the cartilage and the bone surfaces are severely affected, the natural joint is replaced with an artificial joint. The procedure is called total knee arthroplasty (TKA). Lately, the numbers of implanted total knee prostheses grow steadily. An important factor in TKA is the perfect alignment of the total knee prosthesis (TKP) components. Component misalignment can lead to the prosthesis loss by producing wear particles. The paper proposes a study on mechanical behaviors of a TKP based on numerical analysis, using ANSYS software. The numerical analysis is based on both the normal and the changed angle of the components alignment.
Bouchet, R; Mercier, N; Saragaglia, D
2011-02-01
Dislocation is a frequent complication of total hip arthroplasties (THA) especially in older patients, especially when using a posterior approach. In these cases, dual mobility (DM) cups developed by Gilles Bousquet in 1975 can be indicated to reduce this complication risk. Dual mobility cups reduce the rate of dislocation in primary total hip arthroplasty using posterior approach in a single-surgeon series. Test this hypothesis in a controlled study to compare the rate of dislocation in primary total hip arthroplasties done in patients over 50 years old either with a dual mobility cup or a conventional metal-on-polyethylene 28-mm diameter head. Two consecutive series of primary total hip replacements were performed by a single surgeon using a posterolateral approach. The piriformis tendon was left intact. The DM series included 105 patients who underwent arthroplasty between January 2005 and June 2007 with a dual mobility cup (60 women and 45 men, mean age 76.6±5.65 years old [53-93]). The control series (S series) included 108 patients who underwent arthroplasty (56 women and 52 men, mean age 74.2±5.9 years old [53-87]) with a conventional 28-mm polyethylene cup between January 2003 and June 2005. All hip replacements included a 28-mm metal-polyethylene cup and a 12-14-mm Morse taper. Both groups were comparable for gender, diagnosis, body mass index, type of anesthesia and ASA score distribution. All patients included in this series had a minimum follow-up of 1 year. There were no dislocations in the DM series and five early dislocations (before the third month) in the S series for a rate of 4.63%. Although the rate of dislocation was higher in the S series (4.63% vs 0%), the difference was barely significant (P=0.0597). This study comparing the incidence of dislocations after THA with conventional or dual mobility cups, shows that even using a posterior approach and in older patients, dual mobility cups increase stability with no postoperative dislocations. Although results are barely significant, a larger series should confirm the benefit of this implant. In this series, morbidity was not increased with dual mobility cups. Level III: retrospective case-control study. Copyright © 2010 Elsevier Masson SAS. All rights reserved.
A new approach to knee joint arthroplasty.
Zarychta, P
2018-04-01
The main aim of this new approach dedicated to knee arthroplasty is to provide an automated method for determining the cutting planes of both the head of femur and the head of tibia in knee replacement surgery. This paper shows a new approach differing from standard procedures associated with manual determination of the mechanical axis of the lower extremity (during surgery) and replacing them with a procedure based on the imprints (with selected cutting planes) of the two heads of bones. Both these imprints have been performed on the basis of the toposcan of the lower limb (before surgery). This methodology has been implemented in MATLAB and tested in clinical CT images of the lower limb in the coronal and transverse planes (61 studies) and in clinical MRI studies of the knee joint in coronal plane (107 studies). Correct results were obtained for about 90% cases. Copyright © 2017 Elsevier Ltd. All rights reserved.
Salvage Procedures for Management of Prosthetic Joint Infection After Hip and Knee Replacements
Mahmoud, Samer S.S.; Sukeik, Mohamed; Alazzawi, Sulaiman; Shaath, Mohammed; Sabri, Omar
2016-01-01
Background: The increasing load placed by joint replacement surgery on health care systems makes infection, even with the lowest rates, a serious concern that needs to be thoroughly studied and addressed using all possible measures. Methods: A comprehensive review of the current literature on salvage procedures for recurrent PJIs using PubMed, EMBASE and CINAHL has been conducted. Results: Prolonged suppressive antibiotic therapy (PSAT), resection arthroplasty and arthrodesis were the most common procedures performed. Suppressive antibiotic therapy is based on the use of well tolerated long term antibiotics in controlling sensitive organisms. Resection arthroplasty which should be reserved as a last resort provided more predictable outcomes in the hip whereas arthrodesis was associated with better outcomes in the knee. Various methods for arthrodesis including internal and external fixation have been described. Conclusion: Despite good union and infection control rates, all methods were associated with complications occasionally requiring further surgical interventions. PMID:28144373
Total hip replacement for hip fracture: Surgical techniques and concepts.
Coomber, Ross; Porteous, Matthew; Hubble, Matthew J W; Parker, Martyn J
2016-10-01
When treating a hip fracture with a total hip replacement (THR) the surgical technique may differ in a number of aspects in comparison to elective arthroplasty. The hip fracture patient is more likely to have poor bone stock secondary to osteoporosis, be older, have a greater number of co-morbidities, and have had limited peri-operative work-up. These factors lead to a higher risk of complications, morbidity and perioperative mortality. Consideration should be made to performing the THR in a laminar flow theatre, by a surgeon experienced in total hip arthroplasty, using an anterolateral approach, cementing the implant in place, using a large head size and with repair of the joint capsule. Combined Ortho-geriatric care is recommended with similar post-operative rehabilitation to elective THR patients but with less expectation of short length of stay and consideration for fracture prevention measures. Copyright © 2016. Published by Elsevier Ltd.
Madanat, Rami; Hussey, Daniel K; Donahue, Gabrielle S; Potter, Hollis G; Wallace, Robert; Bragdon, Charles R; Muratoglu, Orhun K; Malchau, Henrik
2015-10-01
The purpose of this study was to evaluate whether patients with bilateral metal-on-metal (MoM) hip replacements have symmetric adverse local tissue reactions (ALTRs) at follow-up. An MRI of both hips was performed at a mean time of six years after surgery in 43 patients. The prevalence and severity of ALTRs were found to be similar in simultaneous hips but differences were observed in sequential hips. The order and timing of sequential hip arthroplasties did not affect the severity of ALTRs. Thus, in addition to metal ion exposure from an earlier MoM implant other factors may also play a role in the progression of ALTRs. Bilateral implants should be given special consideration in risk stratification algorithms for management of patients with MoM hip arthroplasty. Copyright © 2015 Elsevier Inc. All rights reserved.
Mortality After Total Knee and Total Hip Arthroplasty in a Large Integrated Health Care System.
Inacio, Maria C S; Dillon, Mark T; Miric, Alex; Navarro, Ronald A; Paxton, Elizabeth W
2017-01-01
The number of excess deaths associated with elective total joint arthroplasty in the US is not well understood. To evaluate one-year postoperative mortality among patients with elective primary and revision arthroplasty procedures of the hip and knee. A retrospective analysis was conducted of hip and knee arthroplasties performed in 2010. Procedure type, procedure volume, patient age and sex, and mortality were obtained from an institutional total joint replacement registry. An integrated health care system population was the sampling frame for the study subjects and was the reference group for the study. Standardized 1-year mortality ratios (SMRs) and 95% confidence intervals (CIs) were calculated. A total of 10,163 primary total knee arthroplasties (TKAs), 4963 primary total hip arthroplasties (THAs), 606 revision TKAs, and 496 revision THAs were evaluated. Patients undergoing primary THA (SMR = 0.6, 95% CI = 0.4-0.7) and TKA (SMR = 0.4, 95% CI = 0.3-0.5) had lower odds of mortality than expected. Patients with revision TKA had higher-than-expected mortality odds (SMR = 1.8, 95% CI = 1.1-2.5), whereas patients with revision THA (SMR = 0.9, 95% CI = 0.4-1.5) did not have higher-than-expected odds of mortality. Understanding excess mortality after joint surgery allows clinicians to evaluate current practices and to determine whether certain groups are at higher-than-expected mortality risk after surgery.
Primary total hip replacement versus hip resurfacing - hospital considerations.
Ward, William G; Carter, Christina J; Barone, Marisa; Jinnah, Riyaz
2011-01-01
Multiple factors regarding surgical procedures and patient selection affect hospital staffing needs as well as hospital revenues. In order to better understand the potential impact on hospitals that hip arthroplasty device selection (standard total hip arthroplasty vs. resurfacing) creates, a review of all primary hip arthroplasties performed at one institution was designed to identify factors that impacted hospital staffing needs and revenue generation. All primary hip arthroplasties undertaken over three fiscal years (2008 to 2010) were reviewed, utilizing only hospital business office data and medical records data that had been previously extracted prior for billing purposes. Analysis confirmed differing demographics for two hip arthroplasty populations, with the resurfacing patients (compared to the conventional total hip arthroplasty population) consisting of younger patients (mean age, 50 vs. 61 years), who were more often male (75% vs. 45%), were more likely to have osteoarthritis as their primary diagnosis (83 vs. 67%) and were more often covered by managed care or commercial insurance (83 vs. 34%). They also had shorter hospital stays (mean length of stay, 2.3 vs. 4.1 days) and consequently provided a more favorable financial revenue stream to the hospital on a per patient basis. Several trends appeared during the study periods. There was a steady increase in all procedures in all groups except for the resurfacings, which decreased 26% in males and 53% in females between 2009 and 2010. Differences were observed in the demographics of patients presenting for resurfacing, compared to those presenting for conventional total hip arthroplasty. In addition to the revenue stream considerations, institutions undertaking a resurfacing program must commit the resources and planning in order to rehabilitate these patients more expeditiously than is usually required with conventional hip arthroplasty patients.
Salesky, Madeleine A; Grace, Trevor R; Feeley, Brian T; Ma, C Benjamin; Zhang, Alan L
2018-05-01
The influence of primary humeral stem fixation method (cemented or press fit) on intraoperative or postoperative outcomes in the setting of revision shoulder arthroplasty is unknown. A retrospective analysis of a prospectively collected cohort of revision shoulder arthroplasty patients from a single tertiary center was performed. Demographic variables, intraoperative data, and 90-day complication rates were compared between cemented and press-fit primary stem fixation cohorts. Follow-up radiographs were graded and compared using a modified Gruen system for humeral lucencies. Eighty-six primary shoulder replacements (34 hemiarthroplasties, 39 anatomic total shoulder arthroplasties, 13 reverse total shoulder arthroplasties) underwent revision arthroplasty with humeral stem removal between 2004 and 2017. Forty-five patients had cemented primary humeral fixation and 41 had press-fit fixation. The cemented cohort was older than the cementless cohort (66.6 vs. 61.4 years; P = .03) but otherwise demonstrated no difference in gender, body mass index, type of primary prosthesis (hemi, total, or reverse), or time between primary and revision operations. The cemented and cementless cohorts showed similar rates of humeral osteotomy (28.9% vs. 29.3%; P = .97), operative time (133.5 vs. 121.3 minutes; P = .16), and 90-day complication rates (13.3% vs. 9.8%; P = .61). Cemented vs. press-fit primary stems also had similar rates of humeral lucencies seen on follow-up radiographs after revision (77.1% vs. 60.6%; P = .14). Humeral stem fixation with or without cement during primary shoulder arthroplasty demonstrated similar operative time, need for intraoperative humeral osteotomy, and postoperative complication rates in the setting of revision arthroplasty. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Deierl, K; Pandit, A; Trakru, S
2014-01-01
Introduction The aim of this prospective study was to investigate the risk of contamination of surgical gloves during preparation and draping in joint replacement surgery. Methods During 46 hip and knee replacement procedures, the gloves of orthopaedic consultants (n=5) and registrars (n=3) were assessed for contamination immediately after draping by impression of gloved fingers on blood agar. Contamination was evaluated by the surgeon’s grade, the type of procedure, the role of the assistant and the dominance of the hand. Results A total of 125 pairs of top gloves were examined (79 pairs from registrars and 46 pairs from consultants). Bacterial contamination was isolated on 19 pairs (15.2%) (16 pairs from registrars and 3 pairs from consultants, p=0.04). Coagulase negative staphylococci were the main isolates and contamination was considered low in all cases (1–5 colonies). Contamination was seen more on the dominant hand (16 gloves from dominant hands and 6 from non-dominant hands, p=0.04), on the index finger and thumb. More contaminated gloves were seen in hip arthroplasty procedures (16 pairs from total hip replacements vs 3 pairs from total knee replacements, p=0.02). Conclusions Contamination of glove fingertips during draping in joint replacement procedures is more likely to occur among junior surgeons, in hip rather than knee arthroplasty procedures and on the dominant hand. It is therefore essential that surgeons of different grades replace gloves used in draping to avoid exposing patients to the risk of infection. PMID:25198974
Na, H S; Shin, H J; Lee, Y J; Kim, J H; Koo, K H; Do, S H
2016-01-01
We evaluated changes in rotational thromboelastometry (ROTEM(®) ) parameters and clinical outcomes in patients undergoing total hip replacement arthroplasty, with concomitant infusions of tranexamic acid and of 6% hydroxyethyl starch 130/0.4. Fifty-five patients were randomly assigned to either the tranexamic acid (n = 29) or the control (n = 26) group. Hydroxyethyl starch was administered in the range of 10-15 ml.kg(-1) during the operation in both groups. In the control group, the clot formation time and maximum clot firmness of APTEM showed significant differences when compared with those of EXTEM at one hour postoperatively, suggestive of fibrinolysis. In the tranexamic acid group, there was no significant difference between each postoperative EXTEM and APTEM parameter. In the tranexamic acid and control group, postoperative blood loss was 308 ml (210-420 [106-745]) and 488 ml (375-620 [170-910], p = 0.002), respectively, and total blood loss was 1168 ml (922-1470 [663-2107]) and 1563 ml (1276-1708 [887-1494], p = 0.003). Haemoglobin concentration was higher in the tranexamic acid group on the second postoperative day (10.5 (9.4-12.1 [7.9-14.0]) vs. 9.6 (8.9-10.5[7.3-16.0]) g.dl(-1) , p = 0.027). In patients undergoing total hip replacement arthroplasty, postoperative fibrinolysis aggravated by hydroxyethyl starch was attenuated by co-administration of 10 mg.kg(-1) tranexamic acid, which may have led to less postoperative blood loss. © 2015 The Association of Anaesthetists of Great Britain and Ireland.
Patellofemoral Arthroplasty: Current Concepts and Review of the Literature
Pisanu, Gabriele; Rosso, Federica; Bertolo, Corrado; Dettoni, Federico; Blonna, Davide; Bonasia, Davide Edoardo; Rossi, Roberto
2017-01-01
Patellofemoral osteoarthritis (PFOA) can be associated with anterior knee pain, stiffness, and functional impairment. Some authors report that PFOA affects approximately 9% of patients older than 40 years with a greater prevalence in females. Etiology of PFOA is multifactorial and is related to the presence of abnormal stresses at the PF joint due to knee- and patient-related factors. The need for a joint preserving treatment by isolated replacement of the injured compartment of the knee led to the development of PF arthroplasty (PFA). When a correct PF replacement is performed, PFA preserves physiologic tibiofemoral joint, thus allowing patients for a rapid recovery with a high satisfaction. The outcomes for PFA are quite variable with a trend toward good to excellent results, mainly owing to the improvement in surgical techniques, patient selection, and implant design. The development of the second generation of PFA improved the outcomes, which is attributed to the different trochlear designs. Recently, encouraging results have been provided by the association of PFA and unicompartmental knee arthroplasty (UKA). In many studies, the main cause of PFA failure is progression of tibiofemoral OA. The aim of this brief review of literature is to summarize the clinical features, indications and contraindications, surgical techniques, complications, and outcomes of PFA. PMID:29270562
Vogt, L; Brettmann, K; Pfeifer, K; Banzer, W
2003-04-08
This study examined the angular gait kinematics of the trunk and the pelvis in the frontal plane and their amount of side-to-side asymmetry in patients after total hip replacement arthroplasty. The angular gait kinematics of 12 male hip arthroplasty patients (53-70 years) were compared to ten age-matched and ten young (24-35 years) male control subjects. Average step times and medio-lateral oscillation amplitudes of the pelvic and thoracic recordings were calculated for each step. Between successive steps the asymmetry ratio was computed and the mean angle around which the side-to-side oscillations occurred was compared to the angle in a symmetrical standing trial. ANOVA indicated no significant side differences in relative step cycle durations. Patients and senior controls had significantly (p<0.01) less pelvis side-to-side displacements than the younger controls. No significant between-group differences could be detected for the average asymmetry ratio. However, during walking the patients showed a significantly (p<0.01) increased lateral thorax and pelvis deviation. Hip replacement patients' thoracic and pelvic position is characterized by a lateral shift throughout the gait cycle, while left and right symmetry of angular movements amplitudes remain at about the same value of unimpaired subjects.
Choi, Eui-Sung; Park, Sang-Jun
2015-06-01
To investigate the incidence of root tears of the posterior horn of the medial meniscus in total knee replacement arthroplasty for knee osteoarthritis and retrospectively analyze clinical results and factors associated with root tears. There were 197 knees of 140 enrolled patients who had undergone total knee replacement arthroplasty between September 2010 and May 2014. The presence of a root tear of the posterior horn of the medial meniscus was confirmed in all patients. Statistical analysis was performed to investigate the correlation between root tears and the possible factors of meniscal tears including gender, age, severity of symptoms (visual analogue scale [VAS] score and medial joint line tenderness), grade of osteoarthritis (Kellgren-Lawrence grading scale), body mass index (BMI), varus deformity, and mechanical axis deviation. Meniscal tears were observed in 154 knees (78.17%). The root tear had correlation with the severity of osteoarthritis (p<0.05), varus deformity (p<0.05), mechanical axis deviation (p<0.05), and BMI (p<0.05). Factors considered to represent the severity of osteoarthritis were found to be associated with root tears of the medial meniscus posterior horn. Increased BMI seemed to be associated with the increased incidence of root tears of the medial meniscus posterior horn.
Pitkin, Mark
2011-01-01
Direct transcutaneous prosthetic attachment (osseointegration) consists of implanting directly into the residuum bone a metal pylon whose external fraction connects the residuum to the external prosthesis. Since the introduction of osseointegration about 20 years ago, the obvious challenge associated with this technology has been the skin-pylon interface as a source of infections. In comparison, the bone-device interface was considered less problematic because of the knowledge and experience inherited from dental implantology and total joint replacement (arthroplasty). Current methods of pylon fixation in osseointegration follow arthroplasty’s paradigm of positioning the pylon’s shaft inside the bone’s medullary canal. However, adopting the medullary canal as a holding compartment for the pylon’s shaft creates the problem of shaft loosening, which has not yet been solved in arthroplasty. PMID:18712634
Havelin, Leif I; Robertsson, Otto; Fenstad, Anne M; Overgaard, Søren; Garellick, Göran; Furnes, Ove
2011-12-21
The Nordic (Scandinavian) countries have had working arthroplasty registers for several years. However, the small numbers of inhabitants and the conformity within each country with respect to preferred prosthesis brands and techniques have limited register research. A collaboration called NARA (Nordic Arthroplasty Register Association) was started in 2007, resulting in a common database for Denmark, Norway, and Sweden with regard to hip replacements in 2008 and primary knee replacements in 2009. Finland joined the project in 2010. A code set was defined for the parameters that all registers had in common, and data were re-coded, within each national register, according to the common definitions. After de-identification of the patients, the anonymous data were merged into a common database. The first study based on this common database included 280,201 hip arthroplasties and the second, 151,814 knee arthroplasties. Kaplan-Meier and Cox multiple regression analyses, with adjustment for age, sex, and diagnosis, were used to calculate prosthesis survival, with any revision as the end point. In later studies, specific reasons for revision were also used as end points. We found differences among the countries concerning patient demographics, preferred surgical approaches, fixation methods, and prosthesis brands. Prosthesis survival was best in Sweden, where cement implant fixation was used more commonly than it was in the other countries. As the comparison of national results was one of the main initial aims of this collaboration, only parameters and data that all three registers could deliver were included in the database. Compared with each separate register, this combined register resulted in reduced numbers of parameters and details. In future collaborations of registers with a focus on comparing the performances of prostheses and articulations, we should probably include only the data needed specifically for the predetermined purposes, from registers that can deliver these data, rather than compiling all data from all registers that are willing to participate.
Gudimetla, Veera; Stewart, Andrew; Luscombe, Karen L; Charalambous, Charalambos P
2012-01-01
Idiopathic thrombocytopenic purpura (ITP) is an autoimmune disorder leading to low platelet count and an increased risk of bleeding. Major joint replacement surgery in a patient with ITP can be associated with severe postoperative bleeding. We present our experience of perioperative management in a patient with severe refractory chronic idiopathic thrombocytopenic purpura who successfully underwent a cemented total knee replacement. PMID:23269964
Increased Long-Term Cardiovascular Risk After Total Hip Arthroplasty
Gordon, Max; Rysinska, Agata; Garland, Anne; Rolfson, Ola; Aspberg, Sara; Eisler, Thomas; Garellick, Göran; Stark, André; Hailer, Nils P.; Sköldenberg, Olof
2016-01-01
Abstract Total hip arthroplasty is a common and important treatment for osteoarthritis patients. Long-term cardiovascular effects elicited by osteoarthritis or the implant itself remain unknown. The purpose of the present study was to determine if there is an increased risk of late cardiovascular mortality and morbidity after total hip arthroplasty surgery. A nationwide matched cohort study with data on 91,527 osteoarthritis patients operated on, obtained from the Swedish Hip Arthroplasty Register. A control cohort (n = 270,688) from the general Swedish population was matched 1:3 to each case by sex, age, and residence. Mean follow-up time was 10 years (range, 7–21). The exposure was presence of a hip replacement for more than 5 years. The primary outcome was cardiovascular mortality after 5 years. Secondary outcomes were total mortality and re-admissions due to cardiovascular events. During the first 5 to 9 years, the arthroplasty cohort had a lower cardiovascular mortality risk compared with the control cohort. However, the risk in the arthroplasty cohort increased over time and was higher than in controls after 8.8 years (95% confidence interval [CI] 7.0–10.5). Between 9 and 13 years postoperatively, the hazard ratio was 1.11 (95% CI 1.05–1.17). Arthroplasty patients were also more frequently admitted to hospital for cardiovascular reasons compared with controls, with a rate ratio of 1.08 (95% CI 1.06–1.11). Patients with surgically treated osteoarthritis of the hip have an increased risk of cardiovascular morbidity and mortality many years after the operation when compared with controls. PMID:26871792
Mobile-bearing total knee arthroplasty: a full traumatic rotation of 180°.
Sudanese, Alessandra; Castiello, Emanuela; Affatato, Saverio
2013-06-25
From February 2008 to September 2012 we implanted 204 mobile-bearing knee prostheses in 192 patients. All the prostheses were cemented (both femoral and tibial components), and the patella was not replaced. Only one early complication of the implants (1/204 = 0.004%) occurred after a traumatic event as a full 180° rotation of the mobile-bearing polyethylene insert. A 78-year-old woman presented with swelling and severe pain at her right knee. This traumatic event was the only case among our mobile-bearing insert patients. The failed polyethylene inserts were retrieved and studied using a scanning electron microscope (SEM, ZEISS EVO 50 EP, Cambridge, UK) operating at 20 kV. Scratching and pitting were found on the UHMWPE insert perpendicular to the machining tracks for the concave surface. SEM micrographs of the insert showed burnishing on the concave surfaces and longitudinal scratches were clearly detectable and well-marked on the analyzed surfaces. A traumatic, fully rotating, polyethylene insert is rare and our case is the first report describing a traumatic event with a complete 180 degree rotation mobile-bearing in a total knee prosthesis. In the literature few reports discuss clinical outcomes after total knee arthroplasty in patients with Parkinson's disease and they cite mixed results. However, some authors suggest that posterior-stabilized and cruciate-retaining TKA should work well while others prefer cruciate-retaining, condylar constrained kinetics, or hinged devices. Although we did not implant a posterior-stabilized mobile-bearing total knee prosthesis or a constrained prosthesis, we obtained good clinical and radiological results at the 2-year followup.
Ke, Xijian; Li, Ji; Liu, Yong; Wu, Xi; Mei, Wei
2017-06-26
Anesthesia management for patients with severe ankylosing spondylitis scheduled for total hip arthroplasty is challenging due to a potential difficult airway and difficult neuraxial block. We report 4 cases with ankylosing spondylitis successfully managed with a combination of lumbar plexus, sacral plexus and T12 paravertebral block. Four patients were scheduled for total hip arthroplasty. All of them were diagnosed as severe ankylosing spondylitis with rigidity and immobilization of cervical and lumbar spine and hip joints. A combination of T12 paravertebral block, lumbar plexus and sacral plexus block was successfully used for the surgery without any additional intravenous anesthetic or local anesthetics infiltration to the incision, and none of the patients complained of discomfort during the operations. The combination of T12 paravertebral block, lumbar plexus and sacral plexus block, which may block all nerves innervating the articular capsule, surrounding muscles and the skin involved in total hip arthroplasty, might be a promising alternative for total hip arthroplasty in ankylosing spondylitis.
Rozell, Joshua C; Courtney, Paul M; Dattilo, Jonathan R; Wu, Chia H; Lee, Gwo-Chin
2016-09-01
Alternative payment models in total joint replacement incentivize cost effective health care delivery and reward reductions in length of stay (LOS), complications, and readmissions. If not adjusted for patient comorbidities, they may encourage restrictive access to health care. We prospectively evaluated 802 consecutive primary total hip arthroplasty and total knee arthroplasty patients evaluating comorbidities associated with increased LOS and readmissions. During this 9-month period, 115 patients (14.3%) required hospitalization >3 days and 16 (1.99%) were readmitted within 90 days. Univariate analysis demonstrated that preoperative narcotic use, heart failure, stroke, chronic kidney disease (CKD), chronic obstructive pulmonary disease (COPD), and liver disease were more likely to require hospitalization >3 days. In multivariate analysis, CKD and COPD were independent risk factors for LOS >3 days. A Charlson comorbidity index >5 points was associated with increased LOS and readmissions. Patients with CKD, COPD, and Charlson comorbidity index >5 points should not be included in alternative payment model for THA and TKA. Copyright © 2016 Elsevier Inc. All rights reserved.
Simultaneous bilateral total knee and ankle arthroplasty as a single surgical procedure.
Pagenstert, Geert; Hintermann, Beat
2011-10-13
Simultaneous osteoarthritis (OA) of the ankle joint complicates primary total knee arthroplasty (TKA). In such cases, rehabilitation of TKA is limited by debilitating ankle pain, but varus or valgus ankle arthritis may even compromise placement of knee prosthetic components. We present a patient with simultaneous bilateral valgus and patellofemoral OA of the knees and bilateral varus OA of the ankle joints that equally contributed to overall disability. This 63 years old, motivated and otherwise healthy patient was treated by simultaneous bilateral total knee and ankle arthroplasty (quadruple total joint arthroplasty, TJA) during the same anesthesia. Two years outcome showed excellent alignment and function of all four replaced joints. Postoperative time for rehabilitation, back to work (6th week) and hospital stay (12 days) of this special patient was markedly reduced compared to the usual course of separate TJA. Simultaneous quadruple TJA in equally disabling OA of bilateral deformed knees and ankles resulted in a better functional outcome and faster recovery compared to the average reported results after TKA and TAA in literature. However, careful preoperative planning, extensive patient education, and two complete surgical teams were considered essential for successful performance. To the best of our knowledge this is the first case report in literature about quadruple major total joint arthroplasty implanted during the same anesthesia in the same patient.
van der Pas, Stéphanie L; Nelissen, Rob G H H; Fiocco, Marta
2017-08-02
In arthroplasty data, patients with staged bilateral total joint arthroplasty (TJA) pose a problem in statistical analysis. Subgroup analysis, in which patients with unilateral and bilateral TJA are studied separately, is sometimes considered an appropriate solution to the problem; we aim to show that this is not true because of immortal time bias. We reviewed patients who underwent staged (at any time) bilateral TJA. The logical fallacy leading to immortal time bias is explained through a simple artificial data example. The cumulative incidences of revision and death are computed by subgroup analysis and by landmark analysis based on hip replacement data from the Dutch Arthroplasty Register and on simulated data sets. For patients who underwent unilateral TJA, subgroup analysis can lead to an overestimate of the cumulative incidence of death and an underestimate of the cumulative incidence of revision. The reverse conclusion holds for patients who underwent staged bilateral TJA. Analysis of these patients can lead to an underestimate of the cumulative incidence of death and an overestimate of the cumulative incidence of revision. Immortal time bias can be prevented by using landmark analysis. When examining arthroplasty registry data, patients who underwent staged bilateral TJA should be analyzed with caution. An appropriate statistical method to address the research question should be selected.
The Need for an Implant Identification Card at Airport Security Check
Kosuge, Dennis; MacDowell, Andrew
2017-01-01
Background Joint replacement surgery is having an increasing demand as national healthcare systems confront an ever ageing population. Surgical complications associated with lower limb arthroplasty are well known but less investigation has been performed examining its effect on air travel, more specifically, unwanted and significant inconvenience caused to travelers going through airport security. Methods In lower limb arthroplasty clinics, 50 patients who met our selection criteria were given questionnaires. Ten airport security officers from 4 international airports (London Stansted, London Gatwick, London Heathrow, and Amsterdam Schiphol International Airport) were also given a separate questionnaire. The opinion of the Civil Aviation Authority was also sought. Results All 50 patients (mean age, 70.4 years; range, 55 to 84 years) who were presenting in lower limb arthroplasty clinics and who met our selection criteria volunteered to enter the study. Twenty-eight of these patients were female (mean age, 69.1 years; range, 55 to 84 years) and 22 were male (mean age, 71.2 years; range, 58 to 81 years). Of the patients, 14% stated that their joint replacements did not set off the airport security alarm. Responses were received from 10 airport security officers as well. Six airport security officers were male and 4 were female. All of the airport officers were aware of some form of implant identification card with 90% stating that these were useful to them at airport security. Eight-four percent of the patients stated that an implant identification card outlining what joint replacement they possessed and when this had been done would be very useful. Sixteen percent of the patients did not think a card would be beneficial since all of them had set off the airport alarm system only once or less in their lifetime. Conclusions It is the opinion of airport security officers and patients that joint replacement implant identification cards streamline airport security checks and decrease the need for more invasive searches at airport security. PMID:28567216
The Need for an Implant Identification Card at Airport Security Check.
Ali, Erden; Kosuge, Dennis; MacDowell, Andrew
2017-06-01
Joint replacement surgery is having an increasing demand as national healthcare systems confront an ever ageing population. Surgical complications associated with lower limb arthroplasty are well known but less investigation has been performed examining its effect on air travel, more specifically, unwanted and significant inconvenience caused to travelers going through airport security. In lower limb arthroplasty clinics, 50 patients who met our selection criteria were given questionnaires. Ten airport security officers from 4 international airports (London Stansted, London Gatwick, London Heathrow, and Amsterdam Schiphol International Airport) were also given a separate questionnaire. The opinion of the Civil Aviation Authority was also sought. All 50 patients (mean age, 70.4 years; range, 55 to 84 years) who were presenting in lower limb arthroplasty clinics and who met our selection criteria volunteered to enter the study. Twenty-eight of these patients were female (mean age, 69.1 years; range, 55 to 84 years) and 22 were male (mean age, 71.2 years; range, 58 to 81 years). Of the patients, 14% stated that their joint replacements did not set off the airport security alarm. Responses were received from 10 airport security officers as well. Six airport security officers were male and 4 were female. All of the airport officers were aware of some form of implant identification card with 90% stating that these were useful to them at airport security. Eight-four percent of the patients stated that an implant identification card outlining what joint replacement they possessed and when this had been done would be very useful. Sixteen percent of the patients did not think a card would be beneficial since all of them had set off the airport alarm system only once or less in their lifetime. It is the opinion of airport security officers and patients that joint replacement implant identification cards streamline airport security checks and decrease the need for more invasive searches at airport security.
Cerebral fat embolism after bilateral total knee replacement arthroplasty -A case report-
Chang, Ri-Na; Lee, Heeseung; Baik, Hee-Jung; Chung, Rack Kyung; Kim, Chi Hyo; Hwang, Tae-Hu
2010-01-01
Fat embolism syndrome is a rare and potentially lethal complication most commonly seen in long bone fractures and intramedullary manipulation. The clinical triad of fat embolism syndrome consists of mental confusion, respiratory distress, and petechiae. This study reports a case of cerebral fat embolism syndrome following elective bilateral total knee replacement. After an uneventful anesthesia and initial recovery, the patient developed neurologic symptoms nine hours postoperatively. PMID:21286442
Cemented total hip replacement cable debris and acetabular construct durability.
Altenburg, Aaron J; Callaghan, John J; Yehyawi, Tameem M; Pedersen, Douglas R; Liu, Steve S; Leinen, Jessica A; Dahl, Kevin A; Goetz, Devon D; Brown, Thomas D; Johnston, Richard C
2009-07-01
Third-body wear can adversely affect the outcome of total hip arthroplasty by causing increased polyethylene wear, osteolysis, and component loosening. We hypothesized that there would be greater generation and migration of metal debris to the bearing surfaces in hips in which cobalt-chromium cables were used to reattach the osteotomized greater trochanter when compared with hips in which stainless steel wires were used. Between June 1981 and December 1983, 196 consecutive total hip arthroplasties were performed with use of an Iowa stem and a titanium-backed cemented acetabular component, with cobalt-chromium cable trochanteric reattachment. After nineteen to twenty years of follow-up, the patients were evaluated with regard to the depth of head penetration into the polyethylene (as a surrogate for wear), osteolysis, loosening, and the need for revision. The results were compared with those for a series of 304 total hip arthroplasties that were performed by the same surgeon from January 1984 to December 1985 with use of the same components and the same surgical technique, but with stainless steel wire trochanteric reattachment. The two groups had a comparable nineteen to twenty-year follow-up. All living patients (fifty-nine hips in the cable group and ninety-two hips in the wire group) had minimum ten-year follow-up radiographs. The polyethylene wear rate was 0.101 mm/yr for the cable group and 0.082 mm/yr for the wire group (p = 0.039). For the living patients, the rate of revision of the acetabular component because of aseptic loosening was 37.3% (twenty-two hips) for the cable group and 20.7% (nineteen hips) for the wire group (p = 0.025). The rate of acetabular osteolysis was 44% (twenty-six hips) for the cable group and 26% (twenty-four hips) for the wire group (p = 0.022). Kaplan-Meier analysis with revision of the acetabular component because of aseptic loosening as the end point demonstrated survival rates of 73.7% +/- 9% and 83% +/- 7% for the cable and wire groups, respectively, at twenty years (p = 0.03). Because cable trochanteric attachment led to significantly greater polyethylene wear, osteolysis, acetabular loosening, and acetabular revision, presumably due to third-body metallic debris generation in this cemented total hip replacement construct, surgeons should be aware of the deleterious effects of third-body debris and avoid the use of potential debris generators in the total hip arthroplasty construct. If cable is used and fretting is recognized, especially with intra-articular migration of metallic material or nonunion of the greater trochanter, consideration should be given to cable removal.
Ashraf, Munis; Priyavadhana, Sruthi; Sambandam, Senthil Nathan; Mounasamy, Varatharaj; Sharma, Om Prakash
2017-01-01
In this era of modern medicine, there is an increase in life expectancy and thereby an ageing population. Among this group one of the most common neurological disorder is Parkinson disease and one of the most common operation done in elderly population is a total joint arthroplasty. But total joint arthroplasty in Parkinson disease is a relatively uncommon entity. There is sparse literature available with regards to total knee arthroplasty (TKA) in Parkinson disease. This review focusses on the necessity, complications and previous experiences on TKA in PD based on the literature available. The review was conducted after a series of advanced search in the following medical databases; Pub med, Biomed central, Cochrane and Google scholar for articles related to total knee replacement in patients with Parkinson's disease. The following keywords were used; Total knee arthroplasty, Parkinson's disease, Hoehn and Yahr, Flexion Contracture. The review indicates that the functional outcome is comparable to that of controls in immediate post-operative phase, one year and three-year phase, but the long term functional outcome seems to deteriorate significantly. Total knee arthroplasty can serve as an effective tool in alleviating pain in short term as well as long term periods, whereas the functional outcome seems to deteriorate post operatively on a long-term basis. Nevertheless, TKA in PD is a challenging situation, thereby necessitating a holistic approach with the efforts from various specialists needed at each stage to ensure a successful operation.
Biomechanics of Reverse Shoulder Arthroplasty: Current Concepts.
Lorenzetti, Adam J; Stone, Geoffrey P; Simon, Peter; Frankle, Mark A
2016-01-01
The evolution of reverse shoulder arthroplasty has provided surgeons with new solutions for many complex shoulder problems. A primary goal of orthopaedics is the restoration or re-creation of functional anatomy to reduce pain and improve function, which can be accomplished by either repairing injured structures or replacing them as anatomically as possible. If reconstructible tissue is lacking or not available, which is seen in patients who have complex shoulder conditions such as an irreparable rotator cuff-deficient shoulder, cuff tear arthropathy, or severe glenoid bone loss, substantial problems may arise. Historically, hemiarthroplasty or glenoid grafting with total shoulder arthroplasty yielded inconsistent and unsatisfactory results. Underlying pathologies in patients who have an irreparable rotator cuff-deficient shoulder, cuff tear arthropathy, or severe glenoid bone loss can considerably alter the mechanical function of the shoulder and create treatment dilemmas that are difficult to overcome. A better biomechanical understanding of these pathologic adaptations has improved treatment options. In the past three decades, reverse total shoulder arthroplasty was developed to treat these complex shoulder conditions not by specifically re-creating the anatomy but by using the remaining functional tissue to improve shoulder balance. Reverse total shoulder arthroplasty has achieved reliable improvements in both pain and function. Initial implant designs lacked scientific evidence to support the design rationale, and many implants failed because surgeons did not completely understand the forces involved or the pathology being treated. Implant function and clinical results will continue to improve as surgeons' biomechanical understanding of shoulder disease and reverse shoulder arthroplasty implants increases.
Third-generation pure alumina and alumina matrix composites in total hip arthroplasty
Hannouche, Didier; Zingg, Matthieu; Miozzari, Hermes; Nizard, Remy; Lübbeke, Anne
2018-01-01
Wear, corrosion and periprosthetic osteolysis are important causes of failure in joint arthroplasty, especially in young patients. Ceramic bearings, developed 40 years ago, are an increasingly popular choice in hip arthroplasty. New manufacturing procedures have increased the strength and reliability of ceramic materials and reduced the risk of complications. In recent decades, ceramics made of pure alumina have continuously improved, resulting in a surgical-grade material that fulfills clinical requirements. Despite the track record of safety and long-term results, third-generation pure alumina ceramics are being replaced in clinical practice by alumina matrix composites, which are composed of alumina and zirconium. In this review, the characteristics of both materials are discussed, and the long-term results with third-generation alumina-on-alumina bearings and the associated complications are compared with those of other available ceramics. Cite this article: EFORT Open Rev 2018;3:7-14. DOI: 10.1302/2058-5241.3.170034 PMID:29657840
Masaracchio, Michael; Hanney, William J.; Liu, Xinliang; Kolber, Morey; Kirker, Kaitlin
2017-01-01
Objective To investigate the role of early initiation of rehabilitation on length of stay (LOS) and cost following total hip arthroplasty, total knee arthroplasty, or unicompartmental knee arthroplasty. Data sources Electronic databases PubMed, CINAHL, Pedro, Embase, AMED, and the Cochrane Library were searched in July 2016. Five additional trials were identified through reference list scanning. Study selection Eligible studies were published in English language peer-reviewed journals; included participants that had undergone total hip arthroplasty, total knee arthroplasty, or unicompartmental knee arthroplasty reported clearly defined timing of rehabilitation onset for at least two groups; and reported at least one measure of LOS or cost. Inclusion criteria were applied by 2 independent authors, with disagreements being determined by a third author. Searching identified 1,029 potential articles, of which 17 studies with 26,614 participants met the inclusion criteria. Data extraction Data was extracted independently by 2 authors, with disagreements being determined by a third author. Methodological quality of each study was evaluated independently by 2 authors using the Downs and Black checklist. Pooled analyses were analyzed using a random-effects model with inverse variance methods to calculate standardized mean differences (SMD) and 95% confidence intervals for LOS. Data synthesis When compared with standard care, early initiation of physical therapy demonstrated a decrease in length of stay for the 4 randomized clinical trials (SMD = -1.90; 95% CI -2.76 to -1.05; I2 = 93%) and for the quasi-experimental and 5 prospective studies (SMD = -1.47; 95% CI -1.85 to -1.10; I2 = 88%). Conclusion Early initiation of rehabilitation following total hip arthroplasty, total knee arthroplasty, or unicompartmental knee arthroplasty is associated with a shorter LOS, a lower overall cost, with no evidence of an increased number of adverse reactions. Additional high quality studies with standardized methodology are needed to further examine the impact of early initiation of physical therapy among patients with joint replacement procedures. PMID:28575058
Nine-year outcome after anatomic stemless shoulder prosthesis: clinical and radiologic results.
Hawi, Nael; Magosch, Petra; Tauber, Mark; Lichtenberg, Sven; Habermeyer, Peter
2017-09-01
Several stemless shoulder implants are available on the market, but only a few studies have presented results with sufficient mid- to long-term follow-up. The present study evaluated clinical and radiologic outcomes 9 years after anatomic stemless shoulder replacement. This is a prospective cohort study evaluating the stemless shoulder prosthesis since 2005. Anatomic stemless shoulder replacement using a single prosthesis was performed in 49 shoulders; 17 underwent total shoulder replacement, and 32 underwent hemiarthroplasty. Forty-three patients were clinically and radiologically monitored after a mean of 9 years (range, 90-127 months; follow-up rate, 88%). The indications for shoulder replacement were primary osteoarthritis in 7 shoulders, post-traumatic in 24, instability in 7, cuff tear arthropathy in 2, postinfectious arthritis in 1, and revision arthroplasty in 2. The Constant-Murley Score improved significantly from 52% to 79% (P < .0001). The active range of motion also increased significantly for flexion from 101° to 118° (P = .022), for abduction from 79° to 105° (P = .02), and for external rotation from 21° to 43° (P < .0001). Radiologic evaluation revealed incomplete radiolucency in 1 patient without clinical significance or further intervention. No revision caused by loosening or countersinking of the humeral implant was observed. The 9-year outcome after stemless shoulder replacement is comparable to that of third- and fourth-generation standard shoulder arthroplasty. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Reliability and concurrent validity of the Dutch hip and knee replacement expectations surveys
2010-01-01
Background Preoperative expectations of outcome of total hip and knee arthroplasty are important determinants of patients' satisfaction and functional outcome. Aims of the study were (1) to translate the Hospital for Special Surgery Hip Replacement Expectations Survey and Knee Replacement Expectations Survey into Dutch and (2) to study test-retest reliability and concurrent validity. Methods Patients scheduled for total hip (N = 112) or knee replacement (N = 101) were sent the Dutch Expectations Surveys twice with a 2 week interval to determine test-retest reliability. To determine concurrent validity, the Expectation WOMAC was sent. Results The results for the Dutch Hip Replacement Expectations Survey revealed good test-retest reliability (ICC 0.87), no bias and good internal consistency (alpha 0.86) (N = 72). The correlation between the Hip Expectations Score and the Expectation WOMAC score was 0.59 (N = 86). The results for the Dutch Knee Replacement Expectations Survey revealed good test-retest reliability (ICC 0.79), no bias and good internal consistency (alpha 0.91) (N = 46). The correlation with the Expectation WOMAC score was 0.52 (N = 57). Conclusions Both Dutch Expectations Surveys are reliable instruments to determine patients' expectations before total hip or knee arthroplasty. As for concurrent validity, the correlation between both surveys and the Expectation WOMAC was moderate confirming that the same construct was determined. However, patients scored systematically lower on the Expectation WOMAC compared to the Dutch Expectation Surveys. Research on patients' expectations before total hip and knee replacement has only been performed in a limited amount of countries. With the Dutch Expectations Surveys it is now possible to determine patients' expectations in another culture and healthcare setting. PMID:20958990
Reliability and concurrent validity of the Dutch hip and knee replacement expectations surveys.
van den Akker-Scheek, Inge; van Raay, Jos J A M; Reininga, Inge H F; Bulstra, Sjoerd K; Zijlstra, Wiebren; Stevens, Martin
2010-10-19
Preoperative expectations of outcome of total hip and knee arthroplasty are important determinants of patients' satisfaction and functional outcome. Aims of the study were (1) to translate the Hospital for Special Surgery Hip Replacement Expectations Survey and Knee Replacement Expectations Survey into Dutch and (2) to study test-retest reliability and concurrent validity. Patients scheduled for total hip (N = 112) or knee replacement (N = 101) were sent the Dutch Expectations Surveys twice with a 2 week interval to determine test-retest reliability. To determine concurrent validity, the Expectation WOMAC was sent. The results for the Dutch Hip Replacement Expectations Survey revealed good test-retest reliability (ICC 0.87), no bias and good internal consistency (alpha 0.86) (N = 72). The correlation between the Hip Expectations Score and the Expectation WOMAC score was 0.59 (N = 86). The results for the Dutch Knee Replacement Expectations Survey revealed good test-retest reliability (ICC 0.79), no bias and good internal consistency (alpha 0.91) (N = 46). The correlation with the Expectation WOMAC score was 0.52 (N = 57). Both Dutch Expectations Surveys are reliable instruments to determine patients' expectations before total hip or knee arthroplasty. As for concurrent validity, the correlation between both surveys and the Expectation WOMAC was moderate confirming that the same construct was determined. However, patients scored systematically lower on the Expectation WOMAC compared to the Dutch Expectation Surveys. Research on patients' expectations before total hip and knee replacement has only been performed in a limited amount of countries. With the Dutch Expectations Surveys it is now possible to determine patients' expectations in another culture and healthcare setting.
Julin, Jaakko; Jämsen, Esa; Puolakka, Timo; Konttinen, Yrjö T; Moilanen, Teemu
2010-08-01
Total knee replacements (TKRs) are being increasingly performed in patients aged < or = 65 years who often have high physical demands. We investigated the relation between age of the patient and prosthesis survival following primary TKR using nationwide data collected from the Finnish Arthroplasty Register. From Jan 1, 1997 through Dec 31, 2003, 32,019 TKRs for primary or secondary osteoarthritis were reported to the Finnish Arthroplasty Register. The TKRs were followed until the end of 2004. During the follow-up, 909 TKRs were revised, 205 (23%) due to infection and 704 for other reasons. Crude overall implant survival improved with increasing age between the ages of 40 and 80. The 5-year survival rates were 92% and 95% in patients aged < or = 55 and 56-65 years, respectively, compared to 97% in patients who were > 65 years of age (p < 0.001). The difference was mainly attributable to reasons other than infections. Sex, diagnosis, type of TKR (condylar, constrained, or hinge), use of patellar component, and fixation method were also associated with higher revision rates. However, the differences in prosthesis survival between the age groups < or = 55, 56-65, and > 65 years remained after adjustment for these factors (p < 0.001). Young age impairs the prognosis of TKR and is associated with increased revision rates for non-infectious reasons. Diagnosis, sex, type of TKR, use of patellar component, and fixation method partly explain the differences, but the effects of physical activity, patient demands, and obesity on implant survival in younger patients warrant further research.
Donauer, Katharina; Bomberg, Hagen; Wagenpfeil, Stefan; Volk, Thomas; Meissner, Winfried; Wolf, Alexander
2018-05-14
Total hip and knee replacements are common surgeries, and an optimal pain treatment is essential for early rehabilitation. Since data from randomized controlled trails on the use of regional anesthesia in joint replacements of the lower extremities are conflicting, we analyzed the international PAIN OUT registry for comparison of regional anesthesia vs. general anesthesia regarding pain and morphine consumption on the first postoperative day. International Classification of Diseases-9 (ICD-9) codes were used to identify 2,346 cases for knee and 2,315 for hip arthroplasty between 2010 and 2016 from the PAIN OUT registry. Those were grouped according to anesthesia provided (general, regional, and a combination of both). At the first day after surgery, pain levels and opioid consumption was compared. Adjusted odds ratios (aOR [95% CI]) were calculated with logistic regression and propensity matching was used as a sensitivity analysis. After adjustment for confounders, regional anesthesia was associated with reduced opioid consumption (0.20 [0.13-0.30], p<0.001) and less pain (0.53 [0.36-0.78], p=0.001) than general anesthesia in knee surgery. In hip surgery, regional anesthesia was only associated with reduced opioid consumption (0.17 [0.11-0.26], p<0.001), whereas pain was comparable (1.23 [0.94-1.61], p=0.1). Results from a propensity-matched sensitivity analysis were similar. In total knee arthroplasty, regional anesthesia was associated with less pain and lower opioid consumption. In total hip arthroplasty, regional anesthesia was associated with a lower opioid consumption, however not with reduced pain levels. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Bager, Louise; Konradsen, Hanne; Dreyer, Pia Sander
2015-12-01
The aim of this study was to describe the meaning of being temporary paralysed from spinal anaesthesia when undergoing total knee replacement. Total knee arthroplasty is a common procedure, and regional anaesthesia is used as a method for anaesthetising the patient. The experience is highly individual in substance and duration, and it can extend far beyond care settings as intraoperative care and the postanaesthesia care unit that have been investigated so far. A qualitative phenomenological hermeneutic design was chosen to gain a deeper understanding of the experience of spinal anaesthesia, as a part of having a total knee replacement. Twelve patients were interviewed in March 2014 after undergoing an elective total knee arthroplasty under spinal anaesthesia. The interviews were analysed with a Ricoeur-inspired interpretation method. Three themes were derived from the interviews: 'anaesthesia--an unavoidable necessity', 'an unrecognisable and incomprehensible body' and 'the body returns--joy and agony'. The results reveal that trust in the health care personnel and knowledge of the course of events play a key role in the experience. The trust can be breached by unforeseen events, or if the patient's experiences were not taken into account. The ability of the health care personnel to be in contact, share relevant knowledge with- and compensate for the patient is crucial in the prevention of negative experiences. The results of this study contribute to insights and deeper knowledge that can enhance staff's ability to provide care for patients undergoing total knee arthroplasty in spinal anaesthesia. The results provide perspectives that argue for care in accordance to individual needs. © 2015 John Wiley & Sons Ltd.
Schindler, Oliver S
2012-02-01
Patellar and femoral component in total knee arthroplasty are inextricably linked as a functional unit. The configuration of this unit has been a matter of ongoing debate, and the myriad of different patellar and femoral components currently available reflect the lack of consensus with respect to the ideal design. One of the major challenges is to overcome the biomechanical disadvantages of a small contact area through which high contact pressures are transferred, making this mechanical construct the weakest part of the prosthetic knee. Contact areas are highly dependent on the congruency of the patellofemoral joint articulation, and are significantly smaller for dome shaped patellar components compared to those of more anatomic designs. However, when exposed to 3-dimensional movements, the contact areas of the dome shaped patella are significantly greater, indicating enhanced forgiveness regarding patellar malpositioning. Although contact stresses, a function of implant design and surface conformity, can reach levels far beyond the yield strength of UHMWPE, catastrophic failure of resurfaced patellar components, commonly seen in metal backed patellae, fashionable in the 1980s, has rarely been observed since. Although plastic deformation and wear of UHMWPE continue to represent a problem, in the absence of suitable alternatives polyethylene remains the bearing surface of choice. The appreciation of the consequences of the mechanical environment on the behaviour of the patellofemoral joint is of particular importance in the endeavour to develop knee replacement systems which provide satisfactory function together with clinical long-term success.
Ten-Year Outcome of Serum Metal Ion Levels After Primary Total Hip Arthroplasty
Levine, Brett R.; Hsu, Andrew R.; Skipor, Anastasia K.; Hallab, Nadim J.; Paprosky, Wayne G.; Galante, Jorge O.; Jacobs, Joshua J.
2013-01-01
Abstract: We previously reported on the metal ion concentrations of cobalt, chromium, and titanium that were found in the serum of patients three years after they had undergone primary total hip arthroplasty as compared with the concentrations found in the serum of control patients who did not have an implant. This study is a concise update on the serum metal levels found in a cohort of these patients ten years after the time of hip implantation. Of the original seventy-five subjects, metal ion levels were available for forty patients (53%). Ten patients (hybrid group) had received a hybrid total hip replacement that consisted of a modular cobalt-alloy femoral stem with a cobalt-alloy femoral head that had been inserted with cement and a titanium acetabular socket that had been inserted without cement. Nine patients (cobalt-chromium [CoCr] group) had received an implant with an extensively porous-coated modular cobalt-alloy femoral stem and femoral head along with a titanium acetabular socket; the femoral and acetabular components had each been inserted without cement. Eight patients (titanium group) had undergone insertion of a proximally porous-coated modular titanium-alloy femoral stem with a cobalt-alloy femoral head and a titanium acetabular socket; the femoral and acetabular components had each been inserted without cement. Thirteen patients (control group) from the original control group of patients who had not received an implant served as control subjects. Serum metal levels were measured with use of high-resolution sector field inductively coupled plasma mass spectrometry. The hybrid total hip arthroplasty group had mean cobalt levels that were 3.2 times higher at 120 months than they were at baseline, and the cobalt levels in that group were significantly higher than those in the titanium total hip arthroplasty group at thirty-six, sixty, eighty-four, ninety-six, and 120 months (p < 0.01). The hybrid group had mean chromium levels that were 3.9 times higher at 120 months than they were at baseline, and the CoCr total hip arthroplasty group had chromium levels that were 3.6 times higher at 120 months than they were at baseline. The serum titanium levels were higher in the titanium group at all follow-up time intervals as compared with the levels in all other groups, and the level in the titanium group at 120 months was eighteen times higher than it was at baseline (p < 0.01). Patients with well-functioning primary metal-on-polyethylene total hip replacements had elevated serum metal levels for as many as ten years postoperatively. Furthermore, metal release at the modular femoral head-neck junctions, rather than passive dissolution from porous ingrowth surfaces, was likely the dominant source of serum cobalt and chromium. Level of Evidence: Therapeutic Level II. See Instructions for Authors for a complete description of levels of evidence. PMID:23515985
Park, Sang-Jun
2015-01-01
Purpose To investigate the incidence of root tears of the posterior horn of the medial meniscus in total knee replacement arthroplasty for knee osteoarthritis and retrospectively analyze clinical results and factors associated with root tears. Materials and Methods There were 197 knees of 140 enrolled patients who had undergone total knee replacement arthroplasty between September 2010 and May 2014. The presence of a root tear of the posterior horn of the medial meniscus was confirmed in all patients. Statistical analysis was performed to investigate the correlation between root tears and the possible factors of meniscal tears including gender, age, severity of symptoms (visual analogue scale [VAS] score and medial joint line tenderness), grade of osteoarthritis (Kellgren-Lawrence grading scale), body mass index (BMI), varus deformity, and mechanical axis deviation. Results Meniscal tears were observed in 154 knees (78.17%). The root tear had correlation with the severity of osteoarthritis (p<0.05), varus deformity (p<0.05), mechanical axis deviation (p<0.05), and BMI (p<0.05). Conclusions Factors considered to represent the severity of osteoarthritis were found to be associated with root tears of the medial meniscus posterior horn. Increased BMI seemed to be associated with the increased incidence of root tears of the medial meniscus posterior horn. PMID:26060607
The AES total ankle replacement: A mid-term analysis of 93 cases.
Henricson, Anders; Knutson, Kaj; Lindahl, Johan; Rydholm, Urban
2010-06-01
There are few studies concerning specific total ankle arthroplasties. This study reports mid-term survival data for the AES prosthesis. Ninety-three AES ankle arthroplasties were performed by the senior authors. The mean follow-up was 3.5 years. The 5-year survivorship and also the number of simultaneous procedures, reoperations, additional procedures and revisions are analyzed. The 5-year survivorship with revision for any reason as end-point was 90%. Simultaneous procedures were performed in 25 patients, deltoid release and subtalar fusion being the most common. There were seven revisions, one due to loosening, and two due to infection, instability and fractures, respectively. Twenty-seven reoperations or additional procedures were performed in 23 patients with a procedure for malleolar impingement being the most common reoperation, and correction of hindfoot varus being the most common reason for an additional procedure. The AES total ankle replacement seems to be a reasonably safe procedure in experienced hands. Copyright 2009 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.
Kassab, Safa; Pietrzak, William S
2014-01-01
Traditional manual instruments for total knee arthroplasty are associated with a malalignment rate of nearly 30%. Patient-specific positioning guides, developed to help address alignment, may also influence other intraoperative factors. This study compared a consecutive series of 270 Vanguard total knee replacements performed with Signature patient-specific positioning guides (study group) to a consecutive series of 595 similar knee replacements performed with manual instrumentation (control group). The study group averaged 16.7 fewer minutes in the operating room (p < .001), utilized tibial inserts that averaged 0.4 mm thinner with a smaller proportion of "thick" tibial inserts (14-18 mm) (p < .001), and required fewer transfusions (p = .022). The Signature-derived surgical plan accurately predicted correct femoral and tibial component sizes in 86.3% and 70.3% of the cases, respectively. These rates increased to 99.3% and 99.2%, respectively, for accuracy to within one size of the surgical plan, similar to published values for manual instrumentation.
Tibial rotation kinematics subsequent to knee arthroplasty
Collins, Duane J.; Khatib, Yasser H.; Parker, David A.; Jenkin, Deanne E.; Molnar, Robert B.
2015-01-01
Background The use of computer assisted joint replacement has facilitated precise intraoperative measurement of knee kinematics. The changes in “screw home mechanism” (SHM) resulting from Total Knee Arthroplasty (TKA) with different prostheses and constraints has not yet been accurately described. Methods A pilot study was first completed. Intraoperative kinematic data was collected two groups of 15 patients receiving different prostheses. Results On average, patients lost 5.3° of ER (SD = 6.1°). There was no significant difference between the prostheses or different prosthetic constraints. Conclusions There significant loss of SHM after TKA. Further research is required to understand its impact on patient function. PMID:25829754
[Gluteal compartment syndrome after total hip replacement. A presentation of two cases].
Villalba, J; Solernou, X
2013-01-01
Many postoperative complications have been described after a total hip arthroplasty, with early and acute, as well as late, complications being reported. Two cases of compartment syndrome of the buttock are described following a hybrid total hip arthroplasty (cemented stem and press-fit and screwed acetabulum) performed on 2 patients of 60 and 68 years old, both diagnosed and treated 24-48 hours after the surgery. Both cases had a primary prosthesis with no previous significant pathological findings. This condition is still rare, and few cases have been described at the medical literature. Copyright © 2012 SECOT. Published by Elsevier Espana. All rights reserved.
Molloy, Ilda B; Martin, Brook I; Moschetti, Wayne E; Jevsevar, David S
2017-03-01
Utilization of total knee and hip arthroplasty has greatly increased in the past decade in the United States; these are among the most expensive procedures in patients with Medicare. Advances in surgical techniques, anesthesia, and care pathways decrease hospital length of stay. We examined how trends in hospital cost were altered by decreases in length of stay. Procedure, demographic, and economic data were collected on 6.4 million admissions for total knee arthroplasty and 2.8 million admissions for total hip arthroplasty from 2002 to 2013 using the National (Nationwide) Inpatient Sample, a component of the Healthcare Cost and Utilization Project. Trends in mean hospital costs and their association with length of stay were estimated using inflation-adjusted, survey-weighted generalized linear regression models, controlling for patient demographic characteristics and comorbidity. From 2002 to 2013, the length of stay decreased from a mean time of 4.06 to 2.97 days for total knee arthroplasty and from 4.06 to 2.75 days for total hip arthroplasty. During the same time period, the mean hospital cost for total knee arthroplasty increased from $14,988 (95% confidence interval [CI], $14,927 to $15,049) in 2002 to $22,837 (95% CI, $22,765 to $22,910) in 2013 (an overall increase of $7,849 or 52.4%). The mean hospital cost for total hip arthroplasty increased from $15,792 (95% CI, $15,706 to $15,878) in 2002 to $23,650 (95% CI, $23,544 to $23,755) in 2013 (an increase of $7,858 or 49.8%). If length of stay were set at the 2002 mean, the growth in cost for total knee arthroplasty would have been 70.8% instead of 52.4% as observed, and the growth in cost for total hip arthroplasty would have been 67.4% instead of 49.8% as observed. Hospital costs for joint replacement increased from 2002 to 2013, but were attenuated by reducing inpatient length of stay. With demographic characteristics showing an upward trend in the utilization of joint arthroplasty, including a shift toward younger population groups, reduction in length of stay remains an important target for procedure-level cost containment under emerging payment models.
Talia, Adrian J; Coetzee, Cassandra; Tirosh, Oren; Tran, Phong
2018-01-08
Total hip arthroplasty is one of the most commonly performed surgical procedures worldwide. There are a number of surgical approaches for total hip arthroplasty and no high-level evidence supporting one approach over the other. Each approach has its unique benefits and drawbacks. This trial aims to directly compare the three most common surgical approaches for total hip arthroplasty. This is a single-centre study conducted at Western Health, Melbourne, Australia; a large metropolitan centre. It is a pragmatic, parallel three-arm, randomised controlled trial. Sample size will be 243 participants (81 in each group). Randomisation will be secure, web-based and managed by an independent statistician. Patients and research team will be blinded pre-operatively, but not post-operatively. Intervention will be either direct anterior, lateral or posterior approach for total hip arthroplasty, and the three arms will be directly compared. Participants will be aged over 18 years, able to provide informed consent and recruited from our outpatients. Patients who are having revision surgery or have indications for hip replacement other than osteoarthritis (i.e., fracture, malignancy, development dysplasia) will be excluded from the trial. The Oxford Hip Score will be determined for patients pre-operatively and 6 weeks, 6, 12 and 24 months post-operatively. The Oxford Hip Score at 24 months will be the primary outcome measure. Secondary outcome measures will be dislocation, infection, intraoperative and peri-prosthetic fracture rate, length of hospital stay and pain level, reported using a visual analogue scale. Many studies have evaluated approaches for total hip arthroplasty and arthroplasty registries worldwide are now collecting this data. However no study to date has compared these three common approaches directly in a randomised fashion. No trial has used patient-reported outcome measures to evaluate success. This pragmatic study aims to identify differences in patient perception of total hip arthroplasty depending on surgical approach. Australian New Zealand Clinical Trials Registry, ACTRN12617000272392 . Registered on 22 February 2017.
[Total Joint Replacement and Return to Sports].
Oehler, N; Schmidt, T; Niemeier, A
2016-12-01
Background: An increasing number of physically active patients not only need to know if they will basically be able to engage in sports after undergoing arthroplasty. They also would like to know whether or not they will be able to resume their preoperative activity levels. This article aims to provide an overview of recent data regarding the following questions on hip, knee and shoulder arthroplasty: (1) What is the impact of physical activity on an endoprosthesis? (2) What level of sports can be achieved after an arthroplasty procedure? (3) What types of sport are recommended for patients with an endoprosthesis? Methods: PubMed-based review of the literature. Narrative review focusing on current data from the years 2010 to 2016. Results: The commonly known recommendation to exercise low-impact sports such as hiking, swimming, cycling or golf at a moderate intensity remains valid for all types of prostheses in all joints. There is broad consensus that the benefits of these sports outweigh the negative effects. Having undergone total hip or knee arthroplasty, most patients with a high preoperative activity level return to sports after 3-6 months, albeit with a clear tendency to lower intensity and a shift from high-impact to low-impact sports. Some key questions have to be answered regarding the effects of low-impact sports that are exercised with high intensity, the effects resulting from high-impact sports, effects specific to different types of sport, and possibilities provided by different prosthesis types. In this context, a lot remains to be done to investigate the limits between positive and negative effects resulting from physical activity of varying intensity. New data suggests that generally a higher physical performance level may be achieved than has been traditionally recommended. Early results of unicondylar knee prostheses are far better than those achieved with bicondylar prostheses. In contrast to expert recommendations, shoulder endoprostheses show the highest postoperative activity levels after inverted arthroplasty, followed by anatomic arthroplasty, and the lowest activity level after the implantation of a hemiprosthesis. Conclusion: There is a significant discrepancy between previous expert recommendations and the actual activity levels that may be achieved after the implantation of a joint prosthesis. Future studies have to define the sports level, the type of sports and the type of prosthesis that provide a positive benefit-risk ratio using state-of-the-art low-abrasion bearing surfaces and prosthesis designs. © Georg Thieme Verlag KG Stuttgart · New York.
[Tumor prostheses : Important in modern revision arthroplasty].
Hillmann, A; Ipach, I
2015-05-01
Due to demographic aging, an increasing number of revision arthroplasty procedures is expected during upcoming years. While the use of a megaprosthesis for bone reconstruction after tumor resection is gold standard, this type of prosthesis still meets with reservation in the field of revision arthroplasty because of numerous risk factors. The purpose of this article is to present the importance of modular megaprostheses in revision arthroplasty, taking into consideration the risks of periprosthetic infection, aseptic loosening, material failure, and hip dislocation. Because of improvements in the field of megaprostheses during the last 30 years, the risks after implantation of this type of prosthesis have significantly decreased. The risk of periprosthetic infection has been reduced about 1/3 by the use of silver surface coating. Improvements in stem design, cement technique, and the additional use of locking screws have minimized the risk of aseptic loosening. Improvements in material composition have reduced the risk of material failure. The risk of hip dislocation could also be minimized by careful tissue preparation and appropriate suture technique. There is no need for the conservative use of megaprostheses in revision arthroplasty. There are many benefits in the use of megaprostheses in multimorbid patients (i.e., reduced operating time, the possibility of early full weight bearing, and a reduced risk of periprosthetic infection by the use of silver surface coating) instead of complex bone reconstruction during revision arthroplasty.
Radiologic changes of ankle joint after total knee arthroplasty.
Lee, Jung Hee; Jeong, Bi O
2012-12-01
The authors noticed that ankle joint osteoarthritis was not uncommon when lower extremity malalignment, such as a knee varus deformity, was present as a result of severe osteoarthritis of the knee. The purpose of this study was to analyze radiologic changes of the ankle joint after total knee arthroplasty. This study included 142 cases in 110 patients who underwent total knee arthroplasty and were followed for at least 3 years. The varus knee group included 128 cases and the valgus knee group included 14 cases. On anteroposterior standing lower extremity radiographs, varus and valgus angles of the knee were measured preoperatively and at the last follow-up. The angle between the ground surface and the distal tibial plafond as well as the upper talus was also measured. In addition, tibial anterior surface angle, talar tilt, space between the medial malleolar distal tip and the medial articular surface of the talus, and medial tibiotalar joint space of the ankle joint were measured. Out of 142 cases, 50 (35.2%) had arthritis in the ankle before total knee arthroplasty and 31 (21.8%) had newly developed or progressive arthritis after surgery. In particular, the varus knee group demonstrated statistically significant differences in preoperative varus deformity, preoperative talar tilt, and postoperative correction angle between the cases that developed or had progressive arthritis and those that did not show any changes (p < .05). After total knee arthroplasty, arthritis developed or progressed in the ankle of many cases radiographically. In particular, when the preoperative talar tilt increased medial to the ankle or the postoperative correction angle was large, the incidence of arthritis in the ankle joint increased. The authors recommend more cautious follow-up on the symptoms of the ankle joint after total knee arthroplasty.
Kasivisvanathan, R; Ramesh, V; Rao Baikady, R; Nadaraja, S
2016-08-01
To estimate the prevalence of preoperative World Health Organization (WHO) defined anaemia in patients presenting for revision hip and knee arthroplasty and its association with transfusion of allogeneic packed red blood cells (PRBC). Studies have mainly investigated the prevalence of preoperative anaemia in primary and not revision hip and knee joint arthroplasty. An analysis of a prospectively collected patient data for 5387 patients having revision hip or knee arthroplasty over a 10-year period at a single high volume centre was conducted. Logistic regression was used to assess whether the presence of WHO defined preoperative anaemia as well as other risk factors were associated with inpatient allogeneic PRBC transfusion. There were 5387 patients assessed of which 3021 (56·01%) patients had revision total hip replacements and 2366 (43·09%) had revision total knee arthroplasty. Of these patients 1956 (36·03%) had preoperative WHO defined anaemia. A total of 2034 (37·08%) patients received at least one unit of allogeneic PRBC during their primary hospital admission. In the final model preoperative WHO defined anaemia was independently associated with allogeneic PRBC transfusion in hip and knee revision surgery OR 4·042 (4·012-4·072 95% CI) CONCLUSIONS: Preoperative anaemia is common in patients presenting for revision hip and knee arthroplasty and independently associated with transfusion of allogeneic PRBC. © 2016 British Blood Transfusion Society.
Amiri, Shahram; Wilson, David R.
2012-01-01
Bicruciate retaining knee arthroplasty, although has shown improved functions and patient satisfaction compared to other designs of total knee replacement, remains a technically demanding option for treating severe cases of arthritic knees. One of the main challenges in bicruciate retaining arthroplasty is proper balancing of the soft tissue during the surgery. In this study biomechanics of soft tissue balancing was investigated using a validated computational model of the knee joint with high fidelity definitions of the soft tissue structures along with a Taguchi method for design of experiments. The model was used to simulate intraoperative balancing of soft tissue structures following the combinations suggested by an orthogonal array design. The results were used to quantify the corresponding effects on the laxity of the joint under anterior-posterior, internal-external, and varus-valgus loads. These effects were ranked for each ligament bundle to identify the components of laxity which were most sensitive to the corresponding surgical modifications. The resulting map of sensitivity for all the ligament bundles determined the components of laxity most suitable for examination during intraoperative balancing of the soft tissue. Ultimately, a sequence for intraoperative soft tissue balancing was suggested for a bicruciate retaining knee arthroplasty. PMID:23082090
Minimally invasive knee arthroplasty: An overview
Tria, Alfred J; Scuderi, Giles R
2015-01-01
Minimally invasive surgery (MIS) for arthroplasty of the knee began with surgery for unicondylar knee arthroplasty (UKA). Partial knee replacements were designed in the 1970s and were amenable to a more limited exposure. In the 1990s Repicci popularized the MIS for UKA. Surgeons began to apply his concepts to total knee arthroplasty. Four MIS surgical techniques were developed: quadriceps sparing, mini-mid vastus, mini-subvastus, and mini-medial parapatellar. The quadriceps sparing technique is the most limited one and is also the most difficult. However, it is the least invasive and allows rapid recovery. The mini-midvastus is the most common technique because it affords slightly better exposure and can be extended. The mini-subvastus technique entirely avoids incising the quadriceps extensor mechanism but is time consuming and difficult in the obese and in the muscular male patient. The mini-parapatellar technique is most familiar to surgeons and represents a good starting point for surgeons who are learning the techniques. The surgeries are easier with smaller instruments but can be performed with standard ones. The techniques are accurate and do lead to a more rapid recovery, with less pain, less blood loss, and greater motion if they are appropriately performed. PMID:26601062
Thangarajah, Tanujan; Falworth, Mark; Lambert, Simon M
2017-01-01
Epileptic seizures can cause shoulder dislocation, recurrent instability and eventually arthritis. The purpose of this study was to report the results, complications and rate of revision surgery following anatomical shoulder arthroplasty in epileptic patients with instability arthropathy. A consecutive series of eight patients with epilepsy underwent anatomical shoulder arthroplasty for recurrent shoulder instability and were retrospectively reviewed after a mean of 4.7 years (range, 2-7.5 years). These included three total shoulder replacements and five humeral resurfacing hemiarthroplasty procedures. Mean age of the cohort was 33 years (range, 17-44). All patients experienced post-operative grand mal seizures. Two patients with hemiarthroplasty required further surgery due to painful glenoid erosion. No residual cases of instability were noted. Mean active forward elevation and external rotation improved following surgery. The Oxford Shoulder Score improved from 15 pre-operatively (range, 7-22) to 26 post-operatively (range, 12-45) ( p = 0.031). This was accompanied by an increase in the mean Subjective Shoulder Value, which improved from 29 (range, 10-80) pre-operatively to 53 (range, 15-90) post-operatively ( p=0.042). Anatomical shoulder arthroplasty may offer a solution for the treatment of instability arthropathy in patients with epilepsy and persistent seizures.
Blömer, Wilhelm; Steinbrück, Arnd; Schröder, Christian; Grothaus, Franz-Josef; Melsheimer, Oliver; Mannel, Henrich; Forkel, Gerhard; Eilers, Thomas; Liebs, Thoralf R; Hassenpflug, Joachim; Jansson, Volkmar
2015-07-01
Every joint registry aims to improve patient care by identifying implants that have an inferior performance. For this reason, each registry records the implant name that has been used in the individual patient. In most registries, a paper-based approach has been utilized for this purpose. However, in addition to being time-consuming, this approach does not account for the fact that failure patterns are not necessarily implant specific but can be associated with design features that are used in a number of implants. Therefore, we aimed to develop and evaluate an implant product library that allows both time saving barcode scanning on site in the hospital for the registration of the implant components and a detailed description of implant specifications. A task force consisting of representatives of the German Arthroplasty Registry, industry, and computer specialists agreed on a solution that allows barcode scanning of implant components and that also uses a detailed standardized classification describing arthroplasty components. The manufacturers classified all their components that are sold in Germany according to this classification. The implant database was analyzed regarding the completeness of components by algorithms and real-time data. The implant library could be set up successfully. At this point, the implant database includes more than 38,000 items, of which all were classified by the manufacturers according to the predefined scheme. Using patient data from the German Arthroplasty Registry, several errors in the database were detected, all of which were corrected by the respective implant manufacturers. The implant library that was developed for the German Arthroplasty Registry allows not only on-site barcode scanning for the registration of the implant components but also its classification tree allows a sophisticated analysis regarding implant characteristics, regardless of brand or manufacturer. The database is maintained by the implant manufacturers, thereby allowing registries to focus their resources on other areas of research. The database might represent a possible global model, which might encourage harmonization between joint replacement registries enabling comparisons between joint replacement registries.
Cost-effectiveness analysis of total ankle arthroplasty.
SooHoo, Nelson F; Kominski, Gerald
2004-11-01
There is renewed interest in total ankle arthroplasty as an alternative to ankle fusion in the treatment of end-stage ankle arthritis. Despite a lack of long-term data on the clinical outcomes associated with these implants, the use of ankle arthroplasty is expanding. The purpose of this cost-effectiveness analysis was to evaluate whether the currently available literature justifies the emerging use of total ankle arthroplasty. This study also identifies thresholds for the durability and function of ankle prostheses that, if met, would support more widespread dissemination of this new technology. A decision model was created for the treatment of ankle arthritis. The literature was reviewed to identify possible outcomes and their probabilities following ankle fusion and ankle arthroplasty. Each outcome was weighted for quality of life with use of a utility factor, and effectiveness was expressed in units of quality-adjusted life years. Gross costs were estimated from Medicare charge and reimbursement data for the relevant codes. The effect of the uncertainty of estimates of costs and effectiveness was assessed with sensitivity analysis. The reference case of our model assumed a ten-year duration of survival of the prosthesis, resulting in an incremental cost-effectiveness ratio for ankle arthroplasty of $18,419 per quality-adjusted life year gained. This reflects a gain of 0.52 quality-adjusted life years at a cost of $9578 when ankle arthroplasty is chosen over fusion. This ratio compares favorably with the cost-effectiveness of other medical and surgical interventions. Sensitivity analysis determined that the cost per quality-adjusted life year gained with ankle arthroplasty rises above $50,000 if the prosthesis is assumed to fail before seven years. Treatment options with ratios above $50,000 per quality-adjusted life year are commonly considered to have limited cost-effectiveness. This threshold is also crossed when the theoretical functional advantages of ankle arthroplasty are eliminated in sensitivity analysis. The currently available literature has not yet shown that total ankle arthroplasty predictably results in levels of durability and function that make it cost-effective at this time. However, the reference case of this analysis does demonstrate that total ankle arthroplasty has the potential to be a cost-effective alternative to ankle fusion. This reference case assumes that the theoretical functional advantages of ankle arthroplasty over ankle fusion will be borne out in future clinical studies. Performance of total ankle replacement will be better justified if these thresholds are met in published long-term clinical trials.
The use of computerized image guidance in lumbar disk arthroplasty.
Smith, Harvey E; Vaccaro, Alexander R; Yuan, Philip S; Papadopoulos, Stephen; Sasso, Rick
2006-02-01
Surgical navigation systems have been increasingly studied and applied in the application of spinal instrumentation. Successful disk arthroplasty requires accurate midline and rotational positioning for optimal function and longevity. A surgical simulation study in human cadaver specimens was done to evaluate and compare the accuracy of standard fluoroscopy, computer-assisted fluoroscopic image guidance, and Iso-C3D image guidance in the placement of lumbar intervertebral disk replacements. Lumbar intervertebral disk prostheses were placed using three different image guidance techniques in three human cadaver spine specimens at multiple levels. Postinstrumentation accuracy was assessed with thin-cut computed tomography scans. Intervertebral disk replacements placed using the StealthStation with Iso-C3D were more accurately centered than those placed using the StealthStation with FluoroNav and standard fluoroscopy. Intervertebral disk replacements placed with Iso-C3D and FluoroNav had improved rotational divergence compared with standard fluoroscopy. Iso-C3D and FluoroNav had a smaller interprocedure variance than standard fluoroscopy. These results did not approach statistical significance. Relative to both virtual and standard fluoroscopy, use of the StealthStation with Iso-C3D resulted in improved accuracy in centering the lumbar disk prosthesis in the coronal midline. The StealthStation with FluoroNav appears to be at least equivalent to standard fluoroscopy and may offer improved accuracy with rotational alignment while minimizing radiation exposure to the surgeon. Surgical guidance systems may offer improved accuracy and less interprocedure variation in the placement of intervertebral disk replacements than standard fluoroscopy. Further study regarding surgical navigation systems for intervertebral disk replacement is warranted.
Palsis, John A; Brehmer, Thomas S; Pellegrini, Vincent D; Drew, Jacob M; Sachs, Barton L
2018-02-21
In an era of mandatory bundled payments for total joint replacement, accurate analysis of the cost of procedures is essential for orthopaedic surgeons and their institutions to maintain viable practices. The purpose of this study was to compare traditional accounting and time-driven activity-based costing (TDABC) methods for estimating the total costs of total hip and knee arthroplasty care cycles. We calculated the overall costs of elective primary total hip and total knee replacement care cycles at our academic medical center using traditional and TDABC accounting methods. We compared the methods with respect to the overall costs of hip and knee replacement and the costs for each major cost category. The traditional accounting method resulted in higher cost estimates. The total cost per hip replacement was $22,076 (2014 USD) using traditional accounting and was $12,957 using TDABC. The total cost per knee replacement was $29,488 using traditional accounting and was $16,981 using TDABC. With respect to cost categories, estimates using traditional accounting were greater for hip and knee replacement, respectively, by $3,432 and $5,486 for personnel, by $3,398 and $3,664 for space and equipment, and by $2,289 and $3,357 for indirect costs. Implants and consumables were derived from the actual hospital purchase price; accordingly, both methods produced equivalent results. Substantial cost differences exist between accounting methods. The focus of TDABC only on resources used directly by the patient contrasts with the allocation of all operating costs, including all indirect costs and unused capacity, with traditional accounting. We expect that the true costs of hip and knee replacement care cycles are likely somewhere between estimates derived from traditional accounting methods and TDABC. TDABC offers patient-level granular cost information that better serves in the redesign of care pathways and may lead to more strategic resource-allocation decisions to optimize actual operating margins.
Short-term outcome of 1,465 computer-navigated primary total knee replacements 2005-2008.
Gøthesen, Oystein; Espehaug, Birgitte; Havelin, Leif; Petursson, Gunnar; Furnes, Ove
2011-06-01
and purpose Improvement of positioning and alignment by the use of computer-assisted surgery (CAS) might improve longevity and function in total knee replacements, but there is little evidence. In this study, we evaluated the short-term results of computer-navigated knee replacements based on data from the Norwegian Arthroplasty Register. Primary total knee replacements without patella resurfacing, reported to the Norwegian Arthroplasty Register during the years 2005-2008, were evaluated. The 5 most common implants and the 3 most common navigation systems were selected. Cemented, uncemented, and hybrid knees were included. With the risk of revision for any cause as the primary endpoint and intraoperative complications and operating time as secondary outcomes, 1,465 computer-navigated knee replacements (CAS) and 8,214 conventionally operated knee replacements (CON) were compared. Kaplan-Meier survival analysis and Cox regression analysis with adjustment for age, sex, prosthesis brand, fixation method, previous knee surgery, preoperative diagnosis, and ASA category were used. Kaplan-Meier estimated survival at 2 years was 98% (95% CI: 97.5-98.3) in the CON group and 96% (95% CI: 95.0-97.8) in the CAS group. The adjusted Cox regression analysis showed a higher risk of revision in the CAS group (RR = 1.7, 95% CI: 1.1-2.5; p = 0.02). The LCS Complete knee had a higher risk of revision with CAS than with CON (RR = 2.1, 95% CI: 1.3-3.4; p = 0.004)). The differences were not statistically significant for the other prosthesis brands. Mean operating time was 15 min longer in the CAS group. With the introduction of computer-navigated knee replacement surgery in Norway, the short-term risk of revision has increased for computer-navigated replacement with the LCS Complete. The mechanisms of failure of these implantations should be explored in greater depth, and in this study we have not been able to draw conclusions regarding causation.
Chitnavis, J; Sinsheimer, J S; Suchard, M A; Clipsham, K; Carr, A J
2000-06-01
To determine and compare the aetiological background, clinical patterns and radiological features of idiopathic osteoarthritis (OA) of the hip and the knee warranting arthroplasty. A total of 402 Caucasians consecutively undergoing total hip replacement (THR) or total knee replacement (TKR) for idiopathic OA at a major centre was surveyed. Previous joint injury was more common in the TKR group (P < 0.0001). However, both groups manifested a mixed occupational background, body mass indices similar to the general population and a predominance of females (F:M = 1.3-1.4:1). The TKR group had a significantly younger age of symptom onset (56 yr) than the THR group (61 yr) but both groups had a tendency to bilateral arthroplasty (33%), nodal involvement (54-59%), a significant excess of right-sided replacements (1.8:1, THR; 2.2:1, TKR) and similar levels of pre-operative pain and disability. Up to 40% of hips manifested acetabular dysplasia and 10% possible previous slipped upper femoral epiphyses. Eighty-five per cent with end-stage coxarthrosis or gonarthrosis had an identical pattern of radiographic disease contralaterally. Our data suggest the importance of a constitutional tendency to idiopathic, end-stage OA, a disorder traditionally associated with environmental factors leading to 'wear and tear'.
Llombart Blanco, Rafael; Valentí, Andrés; Díaz de Rada, Pablo; Mora, Gonzalo; Valentí, Juan R
2014-11-01
Patellar tendon rupture after total knee replacement is a rare and highly limiting injury with multifactorial aetiology. Many reconstruction techniques have been described with not very predictable results. The use of allografts has been accepted as a suitable solution. A series of seven patients with patellar tendon rupture treated with fresh-frozen tendon allograft reconstruction after knee arthroplasty is presented. Median follow-up is 25 months (20-31). Functional assessment improved, and the knee society score and knee functional score improved from 26 and 16 to 82 and 55, respectively. Median extension lag was 5° (0°-20°), with a median range of motion of 95° (70-100). Radiological study showed a rise of the patella of 22.26 mm. The use of fresh-frozen allografts as a solution to patellar tendon ruptures after knee arthroplasty seems to provide acceptable results. Increased patellar height does not seem to affect functionality. Case series, Level IV.
The Cruciate Ligaments in Total Knee Arthroplasty.
Parcells, Bertrand W; Tria, Alfred J
2016-01-01
The early knee replacements were hinge designs that ignored the ligaments of the knee and resurfaced the joint, allowing freedom of motion in a single plane. Advances in implant fixation paved the way for modern designs, including the posterior-stabilized (PS) total knee arthroplasty (TKA) that sacrifices both cruciate ligaments while substituting for the posterior cruciate ligament (PCL), and the cruciate-retaining (CR) TKA designs that sacrifice the anterior cruciate ligament but retain the PCL. The early bicruciate retaining (BCR) TKA designs suffered from loosening and early failures. Townley and Cartier designed BCR knees that had better clinical results but the surgical techniques were challenging.Kinematic studies suggest that normal motion relies on preservation of both cruciate ligaments. Unicompartmental knee arthroplasty retains all knee ligaments and closely matches normal motion, while PS and CR TKA deviate further from normal. The 15% to 20% dissatisfaction rate with current TKA has renewed interest in the BCR design. Replication of normal knee kinematics and proprioception may address some of the dissatisfaction.
Hannouche, Didier; Zingg, Matthieu; Miozzari, Hermes; Nizard, Remy; Lübbeke, Anne
2018-01-01
Wear, corrosion and periprosthetic osteolysis are important causes of failure in joint arthroplasty, especially in young patients.Ceramic bearings, developed 40 years ago, are an increasingly popular choice in hip arthroplasty. New manufacturing procedures have increased the strength and reliability of ceramic materials and reduced the risk of complications.In recent decades, ceramics made of pure alumina have continuously improved, resulting in a surgical-grade material that fulfills clinical requirements.Despite the track record of safety and long-term results, third-generation pure alumina ceramics are being replaced in clinical practice by alumina matrix composites, which are composed of alumina and zirconium.In this review, the characteristics of both materials are discussed, and the long-term results with third-generation alumina-on-alumina bearings and the associated complications are compared with those of other available ceramics. Cite this article: EFORT Open Rev 2018;3:7-14. DOI: 10.1302/2058-5241.3.170034.
Maheshwari, R; Kelley, S P; Langkamer, V G; Loveday, E
2004-10-01
A case of spontaneous recurrent haemarthrosis of the knee presenting 3 months after the unicondylar knee replacement is described. Femoral arteriography demonstrated hypertrophy of the saphenous branch of descending genicular artery with a prominent vascular blush in the region of posteromedial aspect of the popliteal fossa thought to represent a hypertrophic vascular mass of synovium. Therapeutic embolisation of the saphenous branch of descending genicular artery was performed using three fibred platinum coils with satisfactory clinical results. Since the embolisation, the haemarthrosis has not recurred. To our knowledge, this therapeutic procedure used to treat recurrent haemarthrosis following unicondylar knee arthroplasty has not been previously described in the literature.
[Unusual infection complication of total hip arthroplasty].
Jány, R; Vojtassák, J; Lisý, M; Almási, J
2005-01-01
Authors present the case history of a 66-year old patient after repeated reimplantations of the THA with a deep infect caused by a rare aetiological agent (Serratia marcescens) associated with a pyogenic sinus. They describe the disease history, therapeutic procedure, complications associated with the surgery as well as postoperative course after the reimplantation of a customized total hip replacement. In the conclusion they state that in case of an infected total hip arthroplasty the treatment is focused on the salvage of the infection process and preservation of the function of the affected limb. Of essential importance is surgical revision with a radical removal of necrotic tissues and hardware in combination with an intensive parenteral antibiotic administration.
3D printing technology used in severe hip deformity.
Wang, Shanshan; Wang, Li; Liu, Yan; Ren, Yongfang; Jiang, Li; Li, Yan; Zhou, Hao; Chen, Jie; Jia, Wenxiao; Li, Hui
2017-09-01
This study was designed to assess the use of a 3D printing technique in total hip arthroplasty (THA) for severe hip deformities, where new and improved approaches are needed. THAs were performed from January 2015 to December 2016. Bioprosthesis artificial hip joints were used in both conventional and 3D printing hip arthroplasties. A total of 74 patients (57 cases undergoing conventional hip replacements and 17 undergoing 3D printing hip replacements) were followed-up for an average of 24 months. The average age of the patients was 62.7 years. Clinical data between the patients treated with different approaches were compared. Results showed that the time to postoperative weight bearing and the Harris scores of the patients in the 3D printing group were better than those for patients in the conventional hip replacement group. Unfortunately, the postoperative infection and loosening rates were higher in the 3D printing group. However, there were no significant differences in femoral neck anteversion, neck shaft, acetabular or sharp angles between ipsilateral and contralateral sides in the 3D printing group (P>0.05). The femoral neck anteversion angle was significantly different between the two sides in the conventional hip replacement group (P<0.05). Based on these results, we suggest that the 3D printing approach provides a better short-term curative effect that is more consistent with the physiological structure and anatomical characteristics of the patient, and we anticipate that its use will help improve the lives of many patients.
Guery, Jacques; Favard, Luc; Sirveaux, François; Oudet, Didier; Mole, Daniel; Walch, Gilles
2006-08-01
Reverse total shoulder arthroplasty is currently being used to treat selected patients with disabling shoulder arthropathy. The purposes of this study were to investigate the medium-term results of reverse total shoulder arthroplasty and to analyze the influence of etiology on the result. We carried out a multicenter study with a minimum follow-up of five years and determined the survival rate of the prosthesis according to the initial etiology of the shoulder arthropathy. Eighty prostheses were implanted in seventy-seven patients between 1992 and 1998. Sixty-six shoulders had an arthropathy with a massive rotator cuff tear, and fourteen shoulders had a disorder with another etiology (rheumatoid arthritis, trauma, or revision arthropathy). At the time of review, eighteen patients had died and two were lost to follow-up. The remaining fifty-seven patients (sixty shoulders) were examined or interviewed by telephone at a mean follow-up of 69.6 months. Cumulative survival curves were generated with replacement of the prosthesis, glenoid loosening, and a functional Constant score of <30 as the end points. The survival rate with replacement of the prosthesis and glenoid loosening as the end points were 91% and 84%, respectively, at 120 months, with shoulders that had arthropathy with a massive rotator cuff tear demonstrating a significantly better result than those that had a disorder with another etiology (p < 0.05). On the other hand, the survival rate with an absolute Constant score of <30 as an end point was 58% at 120 months, with no significant difference with respect to etiology. Two breaks were observed in the survival curves. The first concerned survival until replacement of the prosthesis and occurred at around three years, reflecting early loosening of the prosthesis. The curve then became stable. A second break started at around six years and reflected progressive deterioration of the functional result. Our findings indicate that the reverse total prosthesis should be reserved for the treatment of very disabling shoulder arthropathy with a massive rotator cuff rupture, and it should be used exclusively in patients over seventy years old with low functional demands.
Kim, Keun Su; Heo, Dong Hwa
2016-07-01
Prospective clinical study. To evaluate the factors that would predispose a patient to heterotopic ossification (HO) formation after cervical arthroplasty. HO after arthroplasty is one of the complications of cervical total disk replacement (TDR). However, the predisposing factors and pathophysiology of HO have not been precisely described. We prospectively enrolled and followed up 23 patients, who received single-level arthroplasty with ProDisc-C, for 5 years after the operation. The patients who developed grade 3 or 4 HO were classified into the "high-grade HO group," whereas the patients with grade 0, 1, or 2 HO were classified into the "low-grade HO group." We compared the postoperative changes in the range of motion (ROM) and height of the functional segmental unit (FSU) of the implantation segments between the 2 groups. The mean differences in height and ROM of the FSU were 2.59±1.42 mm and 6.7±3.2 degrees in the high-grade HO group, and 0.87±0.72 mm and 3.1±2.8 degrees in the low-grade HO group. The mean differences in height and ROM of the FSU were significantly higher in the high-grade HO group than in the low-grade HO group (P<0.05). After cervical arthroplasty, the height of the FSU and ROM of the implantation segments were significantly increased in the high-grade HO group compared with the low-grade HO group. Overcorrection of the height of the FSU and increase in the ROM of the implantation segment may influence the formation of HOs after cervical arthroplasty.
Factors influencing initial cup stability in total hip arthroplasty.
Amirouche, Farid; Solitro, Giovanni; Broviak, Stefanie; Gonzalez, Mark; Goldstein, Wayne; Barmada, Riad
2014-12-01
One of the main goals in total hip replacement is to preserve the integrity of the hip kinematics, by well positioning the cup and to make sure its initial stability is congruent and attained. Achieving the latter is not trivial. A finite element model of the cup-bone interface simulating a realistic insertion and analysis of different scenarios of cup penetration, insertion, under-reaming and loading is investigated to determine certain measurable factors sensitivity to stress-strain outcome. The insertion force during hammering and its relation to the cup penetration during implantation is also investigated with the goal of determining the initial stability of the acetabular cup during total hip arthroplasty. The mathematical model was run in various configurations to simulate 1 and 2mm of under-reaming at various imposed insertion distances to mimic hammering and insertion of cup insertion into the pelvis. Surface contact and micromotion at the cup-bone interface were evaluated after simulated cup insertion and post-operative loading conditions. The results suggest a direct correlation between under-reaming and insertion force used to insert the acetabular cup on the micromotion and fixation at the cup-bone interface. While increased under-reaming and insertion force result in an increase amount of stability at the interface, approximately the same percentage of surface contact and micromotion reduction can be achieved with less insertion force. We need to exercise caution to determine the optimal configuration which achieves a good conformity without approaching the yield strength for bone. Copyright © 2014 Elsevier Ltd. All rights reserved.
Cemented Total Hip Replacement Cable Debris and Acetabular Construct Durability
Altenburg, Aaron J.; Callaghan, John J.; Yehyawi, Tameem M.; Pedersen, Douglas R.; Liu, Steve S.; Leinen, Jessica A.; Dahl, Kevin A.; Goetz, Devon D.; Brown, Thomas D.; Johnston, Richard C.
2009-01-01
Background: Third-body wear can adversely affect the outcome of total hip arthroplasty by causing increased polyethylene wear, osteolysis, and component loosening. We hypothesized that there would be greater generation and migration of metal debris to the bearing surfaces in hips in which cobalt-chromium cables were used to reattach the osteotomized greater trochanter when compared with hips in which stainless steel wires were used. Methods: Between June 1981 and December 1983, 196 consecutive total hip arthroplasties were performed with use of an Iowa stem and a titanium-backed cemented acetabular component, with cobalt-chromium cable trochanteric reattachment. After nineteen to twenty years of follow-up, the patients were evaluated with regard to the depth of head penetration into the polyethylene (as a surrogate for wear), osteolysis, loosening, and the need for revision. The results were compared with those for a series of 304 total hip arthroplasties that were performed by the same surgeon from January 1984 to December 1985 with use of the same components and the same surgical technique, but with stainless steel wire trochanteric reattachment. The two groups had a comparable nineteen to twenty-year follow-up. All living patients (fifty-nine hips in the cable group and ninety-two hips in the wire group) had minimum ten-year follow-up radiographs. Results: The polyethylene wear rate was 0.101 mm/yr for the cable group and 0.082 mm/yr for the wire group (p = 0.039). For the living patients, the rate of revision of the acetabular component because of aseptic loosening was 37.3% (twenty-two hips) for the cable group and 20.7% (nineteen hips) for the wire group (p = 0.025). The rate of acetabular osteolysis was 44% (twenty-six hips) for the cable group and 26% (twenty-four hips) for the wire group (p = 0.022). Kaplan-Meier analysis with revision of the acetabular component because of aseptic loosening as the end point demonstrated survival rates of 73.7% ± 9% and 83% ± 7% for the cable and wire groups, respectively, at twenty years (p = 0.03). Conclusions: Because cable trochanteric attachment led to significantly greater polyethylene wear, osteolysis, acetabular loosening, and acetabular revision, presumably due to third-body metallic debris generation in this cemented total hip replacement construct, surgeons should be aware of the deleterious effects of third-body debris and avoid the use of potential debris generators in the total hip arthroplasty construct. If cable is used and fretting is recognized, especially with intra-articular migration of metallic material or nonunion of the greater trochanter, consideration should be given to cable removal. Level of Evidence: Therapeutic Level III. See Instructions to Authors for a complete description of levels of evidence. PMID:19571089
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kolber, Marcin K.; Shukla, Pratik A.; Kumar, Abhishek
PurposeRecurrent spontaneous hemarthrosis is an infrequent but debilitating late complication of joint replacement, affecting up to 1.6% of patients with arthroplasty of the affected joint. Repeated episodes of bleeding result in an inflammatory cascade that further propagates bleeding events. Open and arthroscopic synovectomy are often performed when conservative treatments fail. Transarterial embolization is increasingly utilized as a less invasive option; however, its role is not widely established. We performed a systematic literature review to report the safety and efficacy of transarterial embolization in treating recurrent hemarthrosis in the setting of prior arthroplasty.Materials and MethodsA systematic review was conducted in accordancemore » with the Preferred Reporting Items for Systematic Review and Meta-Analysis guidelines. A structured search was performed in PubMed, Web of Science, Embase, and SCOPUS databases of patients undergoing embolization for recurrent hemarthrosis after arthroplasty. Patients immediately post-operative, those embolized at first bleeding episode, and those with hemophilia were excluded. Demographic data, clinical information, angiographic findings, treatment, and outcomes were tabulated.ResultsThe search identified 119 titles of which 24 were deemed relevant, comprising 91 patients undergoing 99 embolization procedures. Mean time from prosthesis implantation was 32.2 months. Technical success was 99%. Mean follow-up time was 24.9 months. There were 10 recurrences (10%). Two cases were complicated by joint infection requiring arthroplasty revision.ConclusionsTransarterial embolization for recurrent spontaneous hemarthrosis may be safe and effective in patients having undergone arthroplasty of the affected joint.« less
Comfort, Thomas; Baste, Valborg; Froufe, Miquel Angel; Namba, Robert; Bordini, Barbara; Robertsson, Otto; Cafri, Guy; Paxton, Elizabeth; Sedrakyan, Art; Graves, Stephen
2014-12-17
Differences in survivorship of non-posterior-stabilized compared with posterior-stabilized knee designs carry substantial economic consequences, especially with limited health-care resources. However, these comparisons have often been made between relatively small groups of patients, often with short-term follow-up, with only small differences demonstrated between the groups. The goal of this study is to compare the outcomes of non-posterior-stabilized and posterior-stabilized total knee arthroplasties with use of a unique collaboration of multiple established knee arthroplasty registries. A distributed health data network was developed by the International Consortium of Orthopaedic Registries and was used in this study to reduce barriers to participation (such as security, propriety, legal, and privacy issues) compared with a centralized data warehouse approach. The study included only replacements in osteoarthritis patients who underwent total knee procedures involving fixed-bearing devices from 2001 to 2010. The outcome of interest was time to first revision. On average, not resurfacing showed a more harmful effect than resurfacing did when posterior-stabilized and non-posterior-stabilized knee replacements were compared, while the risk of revision for posterior-stabilized compared with non-posterior-stabilized knees was highest in year zero to one, followed by year one to two, years eight through ten, and years two through eight. Posterior-stabilized knees did significantly worse than non-posterior-stabilized knees did when the patella was not resurfaced. This difference was most pronounced in the first two years (year zero to one: hazard ratio [HR] = 2.15, 95% confidence interval [CI] = 1.56 to 2.95, p < 0.001; year one to two: HR = 1.61, 95% CI = 1.48 to 1.75, p < 0.001). When the patella was resurfaced, posterior-stabilized knees did significantly worse than non-posterior-stabilized knees did. This was again most pronounced in the first two years (year zero to one: HR = 1.75, 95% CI = 1.27 to 2.42, p = 0.001; year one to two: HR = 1.31, 95% CI = 1.19 to 1.45, p < 0.001). There was a reduced risk of revision with a patient age of more than sixty-five years (HR = 0.57, 95% CI = 0.55 to 0.60, p < 0.001). We found that fixed non-posterior-stabilized total knee arthroplasty performed better with or without patellar resurfacing than did fixed posterior-stabilized total knee arthroplasty. This effect was most pronounced in the first two years. The risk of revision for posterior-stabilized total knee arthroplasties was reduced with patellar resurfacing. Also, a patient age of more than sixty-five years and female gender reduced the risk of revision. Copyright © 2014 by The Journal of Bone and Joint Surgery, Incorporated.
Meding, J B; Keating, E M; Ritter, M A; Faris, P M
2000-09-01
The outcome of total knee replacement after high tibial osteotomy remains uncertain. We hypothesized that the results of total knee replacement with or without a previous high tibial osteotomy are similar. The results of a consecutive series of thirty-nine bilateral total knee arthroplasties performed with cement at an average of 8.7 years after unilateral high tibial osteotomy were reviewed. There were twenty-seven men and twelve women. Preoperatively, the knee scores according to the system of the Knee Society were similar for all of the knees; however, valgus alignment and patella infera were more common in the knees with a previous high tibial osteotomy. Bilateral total knee replacement was staged in seven patients and was simultaneous in thirty-two patients. The results of the total knee arthroplasties were retrospectively reviewed with respect to the knee and function scores according to the system of the Knee Society, the radiographic findings, and the complications. Intraoperatively, no notable differences were identified in the number of medial, lateral, or lateral patellar releases required. However, less lateral tibial bone was resected in the group with a previous high tibial osteotomy (average, 3.3 millimeters) than in the group without a high tibial osteotomy (average, 7.5 millimeters). The average duration of follow-up was 7.5 years (range, three to sixteen years) in the group with a previous high tibial osteotomy and 6.8 years (range, two to ten years) in the group without a high tibial osteotomy. At the time of the final follow-up, the knee and function scores were similar for the two groups (89.0 and 81.0 points, respectively, for the group with a previous high tibial osteotomy, and 89.6 and 83.9 points, respectively, for the group without a high tibial osteotomy). Although more knees were free of pain in the group without a previous high tibial osteotomy (thirty-six) than in the group with a previous osteotomy (thirty-three), this difference was not found to be significant with the numbers available (p = 0.4810). Knee alignment and stability, femoral and tibial component alignment, and range of motion also were similar in both groups postoperatively. One allpolyethylene tibial component was revised in the high tibial osteotomy group. Two knees in each group required manipulation. There were no deep infections. While patients with a previous high tibial osteotomy may have important differences preoperatively, including valgus alignment, patella infera, and decreased bone stock in the proximal part of the tibia, the present study suggests that the clinical and radiographic results of primary total knee arthroplasty in knees with and without a previous high tibial osteotomy are not substantially different. In our relatively small group of patients, the previous high tibial osteotomy had no adverse effect on the outcome of the subsequent total knee replacement.
Jäger, Marcus; van Wasen, Andrea; Warwas, Sebastian; Landgraeber, Stefan; Haversath, Marcel; Group, VITAS
2014-01-01
Since polyethylene is one of the most frequently used biomaterials as a liner in total hip arthroplasty, strong efforts have been made to improve design and material properties over the last 50 years. Antioxidants seems to be a promising alternative to further increase durability and reduce polyethylene wear in long term. As of yet, only in vitro results are available. While they are promising, there is yet no clinical evidence that the new material shows these advantages in vivo. To answer the question if vitamin-E enhanced ultra-high molecular weight polyethylene (UHMWPE) is able to improve long-term survivorship of cementless total hip arthroplasty we initiated a randomized long-term multicenter trial. Designed as a superiority study, the oxidation index assessed in retrieval analyses of explanted liners was chosen as primary parameter. Radiographic results (wear rate, osteolysis, radiolucency) and functional outcome (Harris Hip Scores, University of California-Los Angeles, Hip Disability and Osteoarthritis Outcome Score, Visual Analogue Scale) will serve as secondary parameters. Patients with the indication for a cementless total hip arthroplasty will be asked to participate in the study and will be randomized to either receive a standard hip replacement with a highly cross-linked UHMWPE-X liner or a highly cross-linked vitamin-E supplemented UHMWPE-XE liner. The follow-up will be 15 years, with evaluation after 5, 10 and 15 years. The controlled randomized study has been designed to determine if Vitamin-E supplemented highly cross-linked polyethylene liners are superior to standard XLPE liners in cementless total hip arthroplasty. While several studies have been started to evaluate the influence of vitamin-E, most of them evaluate wear rates and functional results. The approach used for this multicenter study, to analyze the oxidation status of retrieved implants, should make it possible to directly evaluate the ageing process and development of the implant material itself over a time period of 15 years. PMID:25002933
Segregation for reduction of regulated medical waste in the operating room: a case report
Shinn, Helen Ki; Kim, Byung-Gun; Yang, Chunwoo; Na, WonJu; Song, Jang-Ho
2017-01-01
One-third of all hospital-regulated medical waste (RMW) comes from the operating room (OR), and it considerably consists of disposable packaging and wrapping materials for the sterilization of surgical instruments. This study sought to identify the amount and type of waste produced by ORs in order to reduce the RMW so as to achieve environmentally-friendly waste management in the OR. We performed an initial waste segregation of 4 total knee replacement arthroplasties (TKRAs) and 1 total hip replacement arthroplasty, and later of 1 extra TKRA, 1 laparoscopic anterior resection of the colon, and 1 pelviscopy (with radical vaginal hysterectomy), performed at our OR. The total mass of non-regulated medical waste (non-RMW) and blue wrap amounted to 30.5 kg (24.9%), and that of RMW to 92.1 kg (75.1%). In the course of the study, we noted that the non-RMW included recyclables, such as papers, plastics, cardboards, and various wrapping materials. The study showed that a reduction in RMW generation can be achieved through the systematic segregation of OR waste. PMID:28184276
Martin, J T; Gullbrand, S E; Kim, D H; Ikuta, K; Pfeifer, C G; Ashinsky, B G; Smith, L J; Elliott, D M; Smith, H E; Mauck, R L
2017-11-17
Total disc replacement with an engineered substitute is a promising avenue for treating advanced intervertebral disc disease. Toward this goal, we developed cell-seeded disc-like angle ply structures (DAPS) and showed through in vitro studies that these constructs mature to match native disc composition, structure, and function with long-term culture. We then evaluated DAPS performance in an in vivo rat model of total disc replacement; over 5 weeks in vivo, DAPS maintained their structure, prevented intervertebral bony fusion, and matched native disc mechanical function at physiologic loads in situ. However, DAPS rapidly lost proteoglycan post-implantation and did not integrate into adjacent vertebrae. To address this, we modified the design to include polymer endplates to interface the DAPS with adjacent vertebrae, and showed that this modification mitigated in vivo proteoglycan loss while maintaining mechanical function and promoting integration. Together, these data demonstrate that cell-seeded engineered discs can replicate many characteristics of the native disc and are a viable option for total disc arthroplasty.
Cross-linked polyethylene does not reduce wear in total knee arthroplasty.
Lasurt-Bachs, S; Torner, P; Maculé, F; Prats, E; Menéndez-García, F; Ríos-Guillermo, J; Torrents, A
To compare two different types of inserts: Ultra-high molecular weight polyethylene (UHMWPE) and cross-linked polyethylene with a quantitative and qualitative study of polyethylene wear particles in synovial fluid 3 years after total knee arthroplasty. A prospective, randomized, controlled cohort study with blinded evaluation was carried out on 25 patients undergoing staged bilateral total knee replacement, 6 months apart. Knee arthrocentesis was performed on 12 patients 3 years after surgery, and the polyethylene particles were analyzed. No significant differences were found in the number of particles generated by the two different types of inserts at 3 years from total knee arthroplasty (3,000×: x¯ cross-linked=849.7; x¯ UHMWPE=796.9; P=.63; 20,000×: x¯ cross-linked=66.3; x¯ UHMWPE=73.1; P=.76). Likewise, no differences in the probability of finding elongated (χ 2 =0.19; P=.66) or rounded (χ 2 =1.44; P=.23) particles in both types of inserts were observed. However, the probability of finding fibrillar particles is 3.08 times greater in UHMWPE. Cross-linked polyethylene does not significantly reduce the generation of polyethylene particles in patients with total knee arthroplasty, 3 years after the surgical procedure. Copyright © 2018 SECOT. Publicado por Elsevier España, S.L.U. All rights reserved.
Jeschke, Elke; Gehrke, Thorsten; Günster, Christian; Hassenpflug, Joachim; Malzahn, Jürgen; Niethard, Fritz Uwe; Schräder, Peter; Zacher, Josef; Halder, Andreas
2016-10-19
Improvements in implant design and surgical technique of unicondylar knee arthroplasty have led to reduced revision rates, but patient selection seems to be crucial for success of such arthroplasties. The purpose of the present study was to analyze the 5-year implant survival rate of unicondylar knee replacements in Germany and to identify patient factors associated with an increased risk of revision, including >30 comorbid conditions. Using nationwide billing data of the largest German health-care insurance for inpatient hospital treatment, we identified patients who underwent unicondylar knee arthroplasty between 2006 and 2012. Kaplan-Meier survival curves with revision as the end point and log-rank tests were used to evaluate 5-year implant survival. A multivariable Cox regression model was used to determine factors associated with revision. The risk factors of age, sex, diagnosis, comorbidities, type of implant fixation, and hospital volume were analyzed. Hazard ratios (HRs) and 95% confidence intervals (95% CIs) were calculated. During the study period, a total of 20,946 unicondylar knee arthroplasties were included. The number of unicondylar knee arthroplasties per year increased during the study period from 2,527 in 2006 to 4,036 in 2012. The median patient age was 64 years (interquartile range, 56 to 72 years), and 60.4% of patients were female. During the time evaluated, the 1-year revision rate decreased from 14.3% in 2006 to 8.7% in 2011. The 5-year survival rate was 87.8% (95% CI, 87.3% to 88.3%). Significant risk factors (p < 0.05) for unicondylar knee arthroplasty revision were younger age (the HR was 2.93 [95% CI, 2.48 to 3.46] for patient age of <55 years, 1.86 [95% CI, 1.58 to 2.19] for 55 to 64 years, and 1.52 [95% CI, 1.29 to 1.79] for 65 to 74 years; patient age of >74 years was used as the reference); female sex (HR, 1.18 [95% CI, 1.07 to 1.29]); complicated diabetes (HR, 1.47 [95% CI, 1.03 to 2.12]); depression (HR, 1.29 [95% CI, 1.06 to 1.57]); obesity, defined as a body mass index of ≥30 kg/m 2 (HR, 1.13 [95% CI, 1.02 to 1.26]); and low-volume hospitals, denoted as an annual hospital volume of ≤10 cases (HR, 1.60 [95% CI, 1.39 to 1.84]), 11 to 20 cases (HR, 1.47 [95% CI, 1.27 to 1.70]), and 21 to 40 cases (HR, 1.31 [95% CI, 1.14 to 1.51]) (>40 cases was used as the reference). Apart from known risk factors, this study showed a significant negative influence of obesity, depression, and complicated diabetes on the 5-year unicondylar knee replacement survival rate. Surgical indications and preoperative patient counseling should consider these findings. Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence. Copyright © 2016 by The Journal of Bone and Joint Surgery, Incorporated.
Soft tissue balancing in total shoulder replacement.
Mueller, Maike; Hoy, Gregory
2014-03-01
Total shoulder arthroplasty is now capable of recreating near anatomic reproduction of native bony shoulder anatomy, but the function and longevity of anatomic shoulder replacement is dependent on a competent soft tissue envelope and adequate motoring of all musculo-tendinous units about the shoulder. Balancing the soft tissues requires understanding of the anatomy and pathology, as well as technical skills. The advent of reverse shoulder biomechanics has brought with it special requirements of understanding of the soft tissue elements still left in the shoulder despite major rotator cuff deficiency.
Biomechanics of a Fixed–Center of Rotation Cervical Intervertebral Disc Prosthesis
Crawford, Neil R.; Baek, Seungwon; Sawa, Anna G.U.; Safavi-Abbasi, Sam; Sonntag, Volker K.H.; Duggal, Neil
2012-01-01
Background Past in vitro experiments studying artificial discs have focused on range of motion. It is also important to understand how artificial discs affect other biomechanical parameters, especially alterations to kinematics. The purpose of this in vitro investigation was to quantify how disc replacement with a ball-and-socket disc arthroplasty device (ProDisc-C; Synthes, West Chester, Pennsylvania) alters biomechanics of the spine relative to the normal condition (positive control) and simulated fusion (negative control). Methods Specimens were tested in multiple planes by use of pure moments under load control and again in displacement control during flexion-extension with a constant 70-N compressive follower load. Optical markers measured 3-dimensional vertebral motion, and a strain gauge array measured C4-5 facet loads. Results Range of motion and lax zone after disc replacement were not significantly different from normal values except during lateral bending, whereas plating significantly reduced motion in all loading modes (P < .002). Plating but not disc replacement shifted the location of the axis of rotation anteriorly relative to the intact condition (P < 0.01). Coupled axial rotation per degree of lateral bending was 25% ± 48% greater than normal after artificial disc replacement (P = .05) but 37% ± 38% less than normal after plating (P = .002). Coupled lateral bending per degree of axial rotation was 37% ± 21% less than normal after disc replacement (P < .001) and 41% ± 36% less than normal after plating (P = .001). Facet loads did not change significantly relative to normal after anterior plating or arthroplasty, except that facet loads were decreased during flexion in both conditions (P < .03). Conclusions In all parameters studied, deviations from normal biomechanics were less substantial after artificial disc placement than after anterior plating. PMID:25694869
Corrosion and Tribology of Materials Used in a Novel Reverse Hip Replacement.
Braddon, Linda; Termanini, Zafer; MacDonald, Steven; Parvizi, Jay; Lieberman, Jay; Frankel, Victor; Zuckerman, Joseph
2017-07-05
Total hip arthroplasty has been utilized for the past 50 years as an effective treatment for degenerative, inflammatory and traumatic disorders of the hip. The design of these implants has generally followed the anatomy of the hip as a ball and socket joint with the femoral head representing the ball and the acetabulum representing the socket. We describe a novel hip arthroplasty design in which the "ball" is located on the acetabular side and the "socket" is located on the femoral side. The results of extensive biomechanical testing are described and document wear and corrosion characteristics that are at least equivalent to standard designs. These results support clinical assessment as the next step of the evaluation.
Corrosion and Tribology of Materials Used in a Novel Reverse Hip Replacement
Braddon, Linda; Termanini, Zafer; MacDonald, Steven; Parvizi, Jay; Lieberman, Jay; Frankel, Victor; Zuckerman, Joseph
2017-01-01
Total hip arthroplasty has been utilized for the past 50 years as an effective treatment for degenerative, inflammatory and traumatic disorders of the hip. The design of these implants has generally followed the anatomy of the hip as a ball and socket joint with the femoral head representing the ball and the acetabulum representing the socket. We describe a novel hip arthroplasty design in which the “ball” is located on the acetabular side and the “socket” is located on the femoral side. The results of extensive biomechanical testing are described and document wear and corrosion characteristics that are at least equivalent to standard designs. These results support clinical assessment as the next step of the evaluation. PMID:28773112
Adhesion force of staphylococcus aureus on various biomaterial surfaces.
Alam, Fahad; Balani, Kantesh
2017-01-01
Staphylococcus comprises of more than half of all pathogens in orthopedic implant infections and they can cause major bone infection which can result in destruction of joint and bone. In the current study, adhesion force of bacteria on the surface of various biomaterial surfaces is measured using atomic force microscope (AFM). Staphylococcus aureus was immobilized on an AFM tipless cantilever as a force probe to measure the adhesion force between bacteria and biomaterials (viz. ultra-high molecular weight poly ethylene (UHMWPE), stainless steel (SS), Ti-6Al-4V alloy, hydroxyapatite (HA)). At the contact time of 10s, UHMWPE shows weak adhesion force (~4nN) whereas SS showed strong adhesion force (~15nN) due to their surface energy and surface roughness. Bacterial retention and viability experiment (3M™ petrifilm test, agar plate) dictates that hydroxyapatite shows the lowest vaibility of bacteria, whereas lowest bacterial retention is observed on UHMWPE surface. Similar results were obtained from live/dead staining test, where HA shows 65% viability, whereas on UHMWPE, SS and Ti-6Al-4V, the bacterial viability is 78%, 94% and 97%, respectively. Lower adhesion forces, constrained pull-off distance (of bacterial) and high antibacterial resistance of bioactive-HA makes it a potential biomaterial for bone-replacement arthroplasty. Copyright © 2016 Elsevier Ltd. All rights reserved.
McAfee, Paul C; Reah, Chris; Gilder, Kye; Eisermann, Lukas; Cunningham, Bryan
2012-05-15
Meta-analysis of 4 prospective randomized controlled Food and Drug Administration (FDA) Investigational Device Exemption (IDE) clinical trials. To maximize the information available from 4 IDE studies by analyzing the combined outcomes of cervical arthroplasty versus fusion at 24-month follow-up. To date, 4 randomized clinical trials have been completed in the United States under FDA IDE protocols to study cervical arthroplasty. Each trial reported arthroplasty to be at least as successful as fusion controls based on noninferiority trial designs. However, sample sizes in any given trial may not be sufficient to demonstrate superiority of treatment effect. Meta-analysis enables pooling of results from comparable trials, which may lead to more precise and statistically significant estimates of treatment effect. Four cervical arthroplasty randomized clinical trials with comparable enrollment criteria and outcome measures were conducted independently by 3 separate sponsors to study the following devices: Bryan, Prestige, ProDisc-C, and PCM cervical disc replacements. A total of 1608 patients were treated across 98 investigative sites. Data were available for 1352 treated patients, of which 1226 were evaluable at 24 months. Assessments included clinical success definitions based on neck disability index, maintenance or improvement of neurological status, subsequent surgery or intervention at the index level (survivorship), and a composite score comprising these as well as serious device-related adverse events. Trial endpoint comparisons were made at 24 months postoperatively. For each endpoint, a random-effects meta-analysis was performed to compare the success rates of cervical arthroplasty with anterior cervical discectomy and fusion (ACDF). Also, supportive frequentist and bayesian analyses were performed. The pooled primary overall success results indicated a statistically significant treatment effect favoring arthroplasty compared with ACDF. Overall success was achieved by 77.6% of the arthroplasty patients and by 70.8% of the ACDF patients (pooled odds ratio [OR]: 0.699, 95% confidence interval [CI]: 0.539-0.908, P = 0.007). The results of the individual subcomponent meta-analyses, all of which favored arthroplasty, were neck disability index success (OR: 0.786, 95% CI: 0.589-1.050, P = 0.103), neurological status (OR: 0.552, 95% CI: 0.364-0.835, P = 0.005), and survivorship (OR: 0.510, 95% CI: 0.275-0.946, P = 0.033). Only the survivorship endpoint suggested low heterogeneity. These findings suggest that cervical arthroplasty is superior to ACDF in overall success, neurological success, and survivorship outcomes at 24 months postoperatively.
Karampinas, Panagiotis K; Papadelis, Eustratios G; Vlamis, John A; Basiliadis, Hlias; Pneumaticos, Spiros G
2017-07-01
Young patients feel that maintaining sport activities after total hip arthroplasty constitutes an important part of their quality of life. The majority of hip surgeons allow patients to return to low-impact activities, but significant caution is advised to taking part in high-impact activities. The purpose of this study is to compare and evaluate the post-operative return to daily living habits and sport activities following short-metaphyseal hip and high functional total hip arthroplasties (resurfacing and big femoral head arthroplasties). In a study design, 48 patients (55 hips) were enrolled in three different comparative groups, one with the short-metaphyseal arthroplasties, a second with high functional resurfacing arthroplasties and a third of big femoral head arthroplasties. Each patient experienced a clinical examination and evaluated with Harris Hip Score, WOMAC, Sf-36, UCLA activity score, satisfaction VAS, anteroposterior and lateral X-rays of the hip and were followed in an outpatient setting for 2 years. Statistical analysis revealed no notable differences between the three groups regarding their demographic data however significant differences have been found between preoperative and postoperative clinical scores of each group. Also, we fail to reveal any significant differences when comparing data of all three groups at the final 2 years postoperative control regarding their clinical scores. The overall outcome of all three groups was similar, all the patients were satisfied and returned to previous level of sport activities. Short metaphyseal hip arthroplasties in young patients intending to return to previous and even high impact sport activities, similar to high functional resurfacing, big femoral head arthroplasties. Short stems with hard on hard bearing surfaces might become an alternative to standard stems and hip resurfacing.
Comparison of cemented and uncemented fixation in total knee arthroplasty.
Brown, Thomas E; Harper, Benjamin L; Bjorgul, Kristian
2013-05-01
As a result of reading this article, physicians should be able to :1. Understand the rationale behind using uncemented fixation in total knee arthroplasty.2.Discuss the current literature comparing cemented and uncemented total knee arthroplasty3. Describe the value of radiostereographic analysis in assessing implant stability.4. Appreciate the limitations in the available literature advocating 1 mode of fixation in total knee arthroplasty. Total knee arthroplasty performed worldwide uses either cemented, cementless, or hybrid (cementless femur with a cemented tibia) fixation of the components. No recent literature review concerning the outcomes of cemented vs noncemented components has been performed. Noncemented components offer the potential advantage of a biologic interface between the bone and implants, which could demonstrate the greatest advantage in long-term durable fixation in the follow-up of young patients undergoing arthroplasty. Several advances have been made in the backing of the tibial components that have not been available long enough to yield long-term comparative follow-up studies. Short-term radiostereographic analysis studies have yielded differing results. Although long-term, high-quality studies are still needed, material advances in biologic fixation surfaces, such as trabecular metal and hydroxyapatite, may offer promising results for young and active patients undergoing total knee arthroplasty when compared with traditional cemented options. Copyright 2013, SLACK Incorporated.
Lecerf, G; Fessy, M H; Philippot, R; Massin, P; Giraud, F; Flecher, X; Girard, J; Mertl, P; Marchetti, E; Stindel, E
2009-05-01
BACKGROUND OBJECTIVE: Femoral offset is supposed to influence the results of hip replacement but little is known about the accurate method of measure and the true effect of offset modifications. This article is a collection of independent anatomic, radiological and clinical works, which purpose is to assess knowledge of the implications of femoral offset for preoperative templating and total hip arthroplasty. There is a strong correlation between femoral offset, abductors lever arm and hip abductor strength. Hip lateralization is independent of the femoral endomedullary characteristics. The abductors lever arm is highly correlated to the gluteus medius activation angle. There were correlations between femoral offset and endomedullary shape. The hip center was high and medial for stovepipe metaphysis while it was lower and lateralized for champagne - flute upper femur. A study was performed to compare the femoral offset measured by X-ray and CT-scan in 50 patients, demonstrated that plain radiography underestimates offset measurement. The 2D templating cannot appreciate the rotation of the lower limb. Taking into account the horizontal plane is essential to obtain proper 3D planning of the femoral offset. A randomized study was designed to compare femoral offset measurements after hip resurfacing and total hip arthroplasty. This study underlined hip resurfacing reduced the femoral offset, while hip replacement increased offset. However, the reduction of femoral offset after hip resurfacing does not affect the function. A pilot study was designed to assess the results of 120 hip arthroplasties with a modular femoral neck. This study showed that the use of a modular collar ensures an easier restoration of the femoral offset. A cohort of high offset stems (Lubinus 117 degrees) was retrospectively assessed. The survival rate was slightly lower that the standard design reported in the Swedish register. Finally, the measurement of offset and leg length was assessed with the help of computer assistance. The software changed the initial schedule (obtained by templating) in 29%. Therefore, femoral offset restoration is essential to improve function and longevity of hip arthroplasty. CT-scan is more accurate than plain radiography to assess femoral offset. Hip resurfacing decreases offset without effect on function. Modular neck and computer assistance may improve intraoperative calculation and reproduction of femoral offset. Increasing offset with a standard cemented design may decrease long-term fixation. Level IV: Retrospective or historical series.
Perazzo, Paolo; Viganò, Marco; De Girolamo, Laura; Verde, Francesco; Vinci, Anna; Banfi, Giuseppe; Romagnoli, Sergio
2013-07-01
Blood loss during total joint arthroplasty strongly influences the time to recover after surgery and the quality of the recovery. Blood conservation strategies such as pre-operative autologous blood donation and post-operative cell salvage are intended to avoid allogeneic blood transfusions and their associated risks. Although widely investigated, the real effectiveness of these alternative transfusion practices remains controversial. The surgery reports of 600 patients undergoing total joint arthroplasty (312 hip and 288 knee replacements) were retrospectively reviewed to assess transfusion needs and related blood management at our institute. Evaluation parameters included post-operative blood loss, haemoglobin concentration measured at different time points, ASA score, and blood transfusion strategies. Autologous blood donation increased the odds of receiving a red blood cell transfusion. Reinfusion by a cell salvage system of post-operative shed blood was found to limit adverse effects in cases of severe post-operative blood loss. The peri-operative net decrease in haemoglobin concentration was higher in patients who had predeposited autologous blood than in those who had not. The strengths of this study are the high number of cases and the standardised procedures, all operations having been performed by a single orthopaedic surgeon and a single anaesthesiologist. Our data suggest that a pre-operative autologous donation programme may often be useless, if not harmful. Conversely, the use of a cell salvage system may be effective in reducing the impact of blood transfusion on a patient's physiological status. Basal haemoglobin concentration emerged as a useful indicator of transfusion probability in total joint replacement procedures.
Dalton, David M; Burke, Thomas P; Kelly, Enda G; Curtin, Paul D
2016-06-01
Surgery is in a constant continuum of innovation with refinement of technique and instrumentation. Arthroplasty surgery potentially represents an area with highly innovative process. This study highlights key area of innovation in knee arthroplasty over the past 35 years using patent and publication metrics. Growth rates and patterns are analyzed. Patents are correlated to publications as a measure of scientific support. Electronic patent and publication databases were searched over the interval 1980-2014 for "knee arthroplasty" OR "knee replacement." The resulting patent codes were allocated into technology clusters. Citation analysis was performed to identify any important developments missed on initial analysis. The technology clusters identified were further analyzed, individual repeat searches performed, and growth curves plotted. The initial search revealed 3574 patents and 16,552 publications. The largest technology clusters identified were Unicompartmental, Patient-Specific Instrumentation (PSI), Navigation, and Robotic knee arthroplasties. The growth in patent activity correlated strongly with publication activity (Pearson correlation value 0.892, P < .01), but was growing at a faster rate suggesting a decline in vigilance. PSI, objectively the fastest growing technology in the last 5 years, is currently in a period of exponential growth that began a decade ago. Established technologies in the study have double s-shaped patent curves. Identifying trends in emerging technologies is possible using patent metrics and is useful information for training and regulatory bodies. The decline in ratio of publications to patents and the uninterrupted growth of PSI are developments that may warrant further investigation. Copyright © 2015 Elsevier Inc. All rights reserved.
Dyrhovden, Gro S; Fenstad, Anne M; Furnes, Ove; Gøthesen, Øystein
2016-12-01
Background and purpose - The long-term effects of computer-assisted surgery in total knee replacement (CAS) compared to conventionally operated knee replacement (CON) are still not clear. We compared survivorship and relative risk of revision in CAS and CON based on data from the Norwegian Arthroplasty Register. Patients and methods - We assessed primary total knee replacements without patellar resurfacing reported to the Norwegian Arthroplasty Register from 2005 through 2014. The 5 most used implants and the 3 most common navigation systems were included. The groups (CAS, n = 3,665; CON, n = 20,019) were compared using a Cox regression analysis adjusted for age, sex, ASA category, prosthesis brand, fixation method, previous surgery, and diagnosis with the risk of revision for any reason as endpoint. Secondary outcomes were reasons for revision and effects of prosthesis brand, fixation method, age (± 65 years), and hospital volume. Results - Prosthesis survival and risk of revision were similar for CAS and CON. CAS had significantly fewer revisions due to malalignment. Otherwise, no statistically significant difference was found between the groups in analyses of secondary outcomes. Mean operating time was 13 minutes longer in CAS. Interpretation - At 8 years of follow-up, CAS and CON had similar rates of overall revision, but CAS had fewer revisions due to malalignment. According to our findings, the benefits of CAS at medium-term follow-up are limited. Further research may identify subgroups that benefit from CAS, and it should also emphasize patient-reported outcomes.
Robertsson, O; Stefánsdóttir, A; Lidgren, L; Ranstam, J
2007-05-01
Patients with osteoarthritis undergoing knee replacement have been reported to have an overall reduced mortality compared with that of the general population. This has been attributed to the selection of healthier patients for surgery. However, previous studies have had a maximum follow-up time of ten years. We have used information from the Swedish Knee Arthroplasty Register to study the mortality of a large national series of patients with total knee replacement for up to 28 years after surgery and compared their mortality with that of the normal population. In addition, for a subgroup of patients operated on between 1980 and 2002 we analysed their registered causes of death to determine if they differed from those expected. We found a reduced overall mortality during the first 12 post-operative years after which it increased and became significantly higher than that of the general population. Age-specific analysis indicated an inverse correlation between age and mortality, where the younger the patients were, the higher their mortality. The shift at 12 years was caused by a relative over-representation of younger patients with a longer follow-up. Analysis of specific causes of death showed a higher mortality for cardiovascular, gastrointestinal and urogenital diseases. The observation that early onset of osteoarthritis of the knee which has been treated by total knee replacement is linked to an increased mortality should be a reason for increased general awareness of health problems in these patients.
Dyrhovden, Gro S; Fenstad, Anne M; Furnes, Ove; Gøthesen, Øystein
2016-01-01
Background and purpose The long-term effects of computer-assisted surgery in total knee replacement (CAS) compared to conventionally operated knee replacement (CON) are still not clear. We compared survivorship and relative risk of revision in CAS and CON based on data from the Norwegian Arthroplasty Register. Patients and methods We assessed primary total knee replacements without patellar resurfacing reported to the Norwegian Arthroplasty Register from 2005 through 2014. The 5 most used implants and the 3 most common navigation systems were included. The groups (CAS, n = 3,665; CON, n = 20,019) were compared using a Cox regression analysis adjusted for age, sex, ASA category, prosthesis brand, fixation method, previous surgery, and diagnosis with the risk of revision for any reason as endpoint. Secondary outcomes were reasons for revision and effects of prosthesis brand, fixation method, age (± 65 years), and hospital volume. Results Prosthesis survival and risk of revision were similar for CAS and CON. CAS had significantly fewer revisions due to malalignment. Otherwise, no statistically significant difference was found between the groups in analyses of secondary outcomes. Mean operating time was 13 minutes longer in CAS. Interpretation At 8 years of follow-up, CAS and CON had similar rates of overall revision, but CAS had fewer revisions due to malalignment. According to our findings, the benefits of CAS at medium-term follow-up are limited. Further research may identify subgroups that benefit from CAS, and it should also emphasize patient-reported outcomes. PMID:27775460
Metal-on-metal surface replacement: a triumph of hope over reason: opposes.
Su, Edwin P; Su, Sherwin L
2011-09-09
Hip resurfacing has been performed for over a decade but still raises controversy as an alternative to traditional total hip arthroplasty (THA). Concerns exist about the potential complications of hip resurfacing, including femoral neck fracture and osteonecrosis of the femoral head. Recently, attention has been given to the metal-on-metal bearing of hip resurfacing with regard to production of metal ions, possible tissue necrosis, and rare instances of metal hypersensitivity. Given the success of the gold-standard THA, it is understandable why some surgeons believe metal-on-metal surface replacement to be "a triumph of hope over reason." However, this article opposes that viewpoint, demonstrating that data exist to justify the practice of preserving bone in younger patients. Hip resurfacing can maintain femoral bone without the expense of removing additional acetabular bone by using modern implants with incremental sizing. Furthermore, many of the problems cited with the bearing couple (such as excess metal production) have been due to poor implant designs, which have now been removed from the market. Finally, we now realize that the metal-on-metal articulation is more sensitive to malposition; thus, good surgical technique and experience can solve many of the problems that have been cited in the past. National registry results confirm that in a select population, hip resurfacing performs comparably to THA, while fulfilling the goal of bone preservation. Copyright 2011, SLACK Incorporated.
The epidemiology of bearing surface usage in total hip arthroplasty in the United States.
Bozic, Kevin J; Kurtz, Steven; Lau, Edmund; Ong, Kevin; Chiu, Vanessa; Vail, Thomas P; Rubash, Harry E; Berry, Daniel J
2009-07-01
Hard-on-hard bearings offer the potential to improve the survivorship of total hip arthroplasty implants. However, the specific indications for the use of these advanced technologies remain controversial. The purpose of this study was to characterize the epidemiology of bearing surface utilization in total hip arthroplasty in the United States with respect to patient, hospital, geographic, and payer characteristics. The Nationwide Inpatient Sample database was used to analyze bearing type and demographic characteristics associated with 112,095 primary total hip arthroplasties performed in the United States between October 1, 2005, and December 31, 2006. The prevalence of each type of total hip arthroplasty bearing was calculated for population subgroups as a function of age, sex, census region, payer class, and hospital type. The most commonly reported bearing was metal-on-polyethylene (51%) followed by metal-on-metal (35%) and ceramic-on-ceramic (14%). Metal-on-polyethylene bearings were most commonly reported in female Medicare patients who were sixty-five to seventy-four years old, while metal-on-metal and ceramic-on-ceramic bearings were most commonly reported in privately insured male patients who were less than sixty-five years old. Thirty-three percent of patients over sixty-five years old had a hard-on-hard bearing reported. There was substantial regional variation in bearing usage; the highest prevalence of metal-on-polyethylene bearings was reported in the Northeast and at nonteaching hospitals, and the highest prevalence of metal-on-metal bearings was reported in the South and at teaching hospitals. The usage of total hip arthroplasty bearings varies considerably by patient characteristics, hospital type, and geographic location throughout the United States. Despite uncertain advantages in older patients, hard-on-hard bearings are commonly used in patients over the age of sixty-five years. Further study is necessary to define the appropriate indications for these advanced technologies in total hip arthroplasty.
2013-01-01
Background Conversion of a knee arthrodesis to a Total Knee Arthroplasty is an uncommon procedure. Revision Total Knee Arthroplasty in this setting presents the surgeon with a number of challenges including the management of the extensor mechanism and patella. Case presentation We describe a unique case of a 69 years old Caucasian man who underwent a revision Total Knee Arthroplasty using a tibial tubercle osteotomy after a previous conversion of a knee arthrodesis without patella resurfacing. Unfortunately 9 months following surgery a tibial tubercle pseudarthrosis and spontaneous patella fracture occurred. Both were managed with open reduction and internal fixation. At 30 months follow-up the tibial tubercle osteotomy had completely consolidated while the patella fracture was still evident but with no signs of further displacement. The patient was completely satisfied with the outcome and had a painless range of knee flexion between 0-95°. Conclusions We believe that patients undergoing this type of surgery require careful counseling regarding the risk of complications both during and after surgery despite strong evidence supporting improved functional outcomes. PMID:24195600
Kwon, Sae Kwang; Kang, Yeon Gwi; Kim, Sung Ju; Chang, Chong Bum; Seong, Sang Cheol; Kim, Tae Kyun
2010-10-01
Patient satisfaction is becoming increasingly important as a crucial outcome measure for total knee arthroplasty. We aimed to determine how well commonly used clinical outcome scales correlate with patient satisfaction after total knee arthroplasty. In particular, we sought to determine whether patient satisfaction correlates better with absolute postoperative scores or preoperative to 12-month postoperative changes. Patient satisfaction was evaluated using 4 grades (enthusiastic, satisfied, noncommittal, and disappointed) for 438 replaced knees that were followed for longer than 1 year. Outcomes scales used the American Knee Society, Western Ontario McMaster University Osteoarthritis Index scales, and Short Form-36 scores. Correlation analyses were performed to investigate the relation between patient satisfaction and the 2 different aspects of the outcome scales: postoperative scores evaluated at latest follow-ups and preoperative to postoperative changes. The Western Ontario McMaster University Osteoarthritis Index scales function score was most strongly correlated with satisfaction (correlation coefficient=0.45). Absolute postoperative scores were better correlated with satisfaction than the preoperative to postoperative changes for all scales. Level IV (retrospective case series). Copyright © 2010 Elsevier Inc. All rights reserved.
[Modern unicondylar knee arthroplasty. Tips and tricks].
von Knoch, F; Munzinger, U
2014-05-01
Unicondylar knee arthroplasty (UKA) is an established therapeutic option for advanced medial or lateral gonarthrosis. The cornerstones of a successful UKA, careful patient selection, preoperative planning and precise operation technique, are discussed in this overview article. In contrast to total knee arthroplasty, UKA allows preservation of the contralateral and patellofemoral compartments as well as the cruciate ligaments and is often associated with rapid postoperative recovery, improved knee kinematics and knee function. However, UKA is technically very demanding. High revision rates have been reported in particular with widespread application, according to national joint replacement registries. Successful UKA relies on meticulous patient selection, preoperative planning and surgical technique. It is justified to broaden classic UKA indications. In medial and lateral UKA three types of mechanical varus-valgus deformity can be encountered: type 1 (isolated intraarticular deformity), type 2 (pronounced deformity due to extraarticular varus deformity in medial UKA or valgus deformity in lateral UKA), type 3 (reduced deformity due to extraarticular valgus deformity in medial UKA or varus deformity in lateral UKA). We believe these deformities should be addressed accordingly with surgical technique.
Radiographic parameters associated with pain following total hip and surface arthroplasty.
Nam, Denis; Sauber, Timothy J; Barrack, Toby; Johnson, Staci R; Brooks, Peter J; Nunley, Ryan M
2015-03-01
Pain following total hip arthroplasty (THA) and surface arthroplasty (SRA) remains a significant source of patient dissatisfaction. Two hundred twenty-four SRA and 196 THA patients completed a pain drawing questionnaire and postoperative radiographic measurements of component positioning were performed. In the SRA cohort, 11 of 21 patients (52%) with acetabular uncoverage of ≥5 mm versus 43 of 147 (29%) with acetabular uncoverage of ≤4.9 mm reported groin pain (P=.03). In the THA cohort, an increased distal-third canal fill ratio and a lower canal calcar ratio trended towards a higher incidence of thigh pain (P=.10 and .06), while a decreased mid-third canal fill ratio was associated with increased severity of thigh pain (P=.04). This study identifies associations between radiographic findings and pain following THA and SRA. Copyright © 2014 Elsevier Inc. All rights reserved.
Short-term outcome of 1,465 computer-navigated primary total knee replacements 2005–2008
2011-01-01
Background and purpose Improvement of positioning and alignment by the use of computer-assisted surgery (CAS) might improve longevity and function in total knee replacements, but there is little evidence. In this study, we evaluated the short-term results of computer-navigated knee replacements based on data from the Norwegian Arthroplasty Register. Patients and methods Primary total knee replacements without patella resurfacing, reported to the Norwegian Arthroplasty Register during the years 2005–2008, were evaluated. The 5 most common implants and the 3 most common navigation systems were selected. Cemented, uncemented, and hybrid knees were included. With the risk of revision for any cause as the primary endpoint and intraoperative complications and operating time as secondary outcomes, 1,465 computer-navigated knee replacements (CAS) and 8,214 conventionally operated knee replacements (CON) were compared. Kaplan-Meier survival analysis and Cox regression analysis with adjustment for age, sex, prosthesis brand, fixation method, previous knee surgery, preoperative diagnosis, and ASA category were used. Results Kaplan-Meier estimated survival at 2 years was 98% (95% CI: 97.5–98.3) in the CON group and 96% (95% CI: 95.0–97.8) in the CAS group. The adjusted Cox regression analysis showed a higher risk of revision in the CAS group (RR = 1.7, 95% CI: 1.1–2.5; p = 0.02). The LCS Complete knee had a higher risk of revision with CAS than with CON (RR = 2.1, 95% CI: 1.3–3.4; p = 0.004)). The differences were not statistically significant for the other prosthesis brands. Mean operating time was 15 min longer in the CAS group. Interpretation With the introduction of computer-navigated knee replacement surgery in Norway, the short-term risk of revision has increased for computer-navigated replacement with the LCS Complete. The mechanisms of failure of these implantations should be explored in greater depth, and in this study we have not been able to draw conclusions regarding causation. PMID:21504309
Boileau, Pascal; Moineau, Grégory; Roussanne, Yannick; O'Shea, Kieran
2011-09-01
Scapular notching, prosthetic instability, limited shoulder rotation and loss of shoulder contour are associated with conventional medialized design reverse shoulder arthroplasty. Prosthetic (ie, metallic) lateralization increases torque at the baseplate-glenoid interface potentially leading to failure. We asked whether bony lateralization of reverse shoulder arthroplasty would avoid the problems caused by humeral medialization without increasing torque or shear force applied to the glenoid component. We prospectively followed 42 patients with rotator cuff deficiency treated with bony increased-offset reverse shoulder arthroplasty. A cylinder of autologous cancellous bone graft, harvested from the humeral head, was placed between the reamed glenoid surface and baseplate. Graft and baseplate fixation was achieved using a lengthened central peg (25 mm) and four screws. Patients underwent clinical, radiographic, and CT assessment at a minimum of 2 years after surgery. The humeral graft incorporated completely in 98% of cases (41 of 42) and partially in one. At a mean of 28 months postoperatively, no graft resorption, glenoid loosening, or postoperative instability was observed. Inferior scapular notching occurred in 19% (eight of 42). The absolute Constant-Murley score improved from 31 to 67. Thirty-six patients (86%) were able to internally rotate sufficiently to reach their back over the sacrum. Grafting of the glenoid surface during reverse shoulder arthroplasty effectively creates a long-necked scapula, providing the benefits of lateralization. Bony increased-offset reverse shoulder arthroplasty is associated with low rates of inferior scapular notching, improved shoulder rotation, no prosthetic instability and improved shoulder contour. In contrast to metallic lateralization, bony lateralization has the advantage of maintaining the prosthetic center of rotation at the prosthesis-bone interface, thus minimizing torque on the glenoid component. Level IV, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.
Barlow, Brian T; Ortiz, Philippe A; Boles, John W; Lee, Yuo-Yu; Padgett, Douglas E; Westrich, Geoffrey H
2017-05-01
The recent experiences with adverse local tissue reactions have highlighted the need to establish what are normal serum levels of cobalt (Co), chromium (Cr), and titanium (Ti) after hip arthroplasty. Serum Co, Cr, and Ti levels were measured in 80 nonconsecutive patients with well-functioning unilateral total hip arthroplasty and compared among 4 bearing surfaces: ceramic-on-ceramic (CoC); ceramic-on-polyethylene (CoP); metal-on-polyethylene (MoP), and dual mobility (DM). The preoperative and most recent University of California, Los Angeles (UCLA) and Western Ontario and McMaster Universities Arthritis Index (WOMAC) scores were compared among the different bearing surfaces. No significant difference was found among serum Co and Cr levels between the 4 bearing surface groups (P = .0609 and P = .1577). Secondary analysis comparing metal and ceramic femoral heads demonstrated that the metal group (MoP, modular dual mobility (Stryker Orthopedics, Mahwah, NJ) [metal]) had significant higher serum Co levels compared with the ceramic group (CoC, CoP, MDM [ceramic]) (1.05 mg/L ± 1.25 vs 0.59 mg/L ± 0.24; P = .0411). Spearman coefficient identified no correlation between metal ion levels and patient-reported outcome scores. No serum metal ion level differences were found among well-functioning total hip arthroplasty with modern bearing couples. Significantly higher serum Co levels were seen when comparing metal vs ceramic femoral heads in this study and warrants further investigation. Metal ion levels did not correlate with patient-reported outcome measures. Copyright © 2016 Elsevier Inc. All rights reserved.
Kinematic analysis of anterior cruciate ligament reconstruction in total knee arthroplasty
Liu, Hua-Wei; Ni, Ming; Zhang, Guo-Qiang; Li, Xiang; Chen, Hui; Zhang, Qiang; Chai, Wei; Zhou, Yong-Gang; Chen, Ji-Ying; Liu, Yu-Liang; Cheng, Cheng-Kung; Wang, Yan
2016-01-01
Background: This study aims to retain normal knee kinematics after knee replacement surgeries by reconstructing anterior cruciate ligament during total knee arthroplasty. Method: We use computational simulation tools to establish four dynamic knee models, including normal knee model, posterior cruciate ligament retaining knee model, posterior cruciate ligament substituting knee model, and anterior cruciate ligament reconstructing knee model. Our proposed method utilizes magnetic resonance images to reconstruct solid bones and attachments of ligaments, and assemble femoral and tibial components according representative literatures and operational specifications. Dynamic data of axial tibial rotation and femoral translation from full-extension to 135 were measured for analyzing the motion of knee models. Findings: The computational simulation results show that comparing with the posterior cruciate ligament retained knee model and the posterior cruciate ligament substituted knee model, reconstructing anterior cruciate ligament improves the posterior movement of the lateral condyle, medial condyle and tibial internal rotation through a full range of flexion. The maximum posterior translations of the lateral condyle, medial condyle and tibial internal rotation of the anterior cruciate ligament reconstructed knee are 15.3 mm, 4.6 mm and 20.6 at 135 of flexion. Interpretation: Reconstructing anterior cruciate ligament in total knee arthroplasty has been approved to be an more efficient way of maintaining normal knee kinematics comparing to posterior cruciate ligament retained and posterior cruciate ligament substituted total knee arthroplasty. PMID:27347334
Manipulation for stiffness following total knee arthroplasty: when and how often to do it?
Desai, Aravind S; Karmegam, Anand; Dramis, Asterios; Board, Tim N; Raut, Videsh
2014-10-01
Stiffness following total knee arthroplasty is a disabling complication. One of the management options of stiffness includes manipulation under anaesthesia, but no real consensus exist on appropriate timing of intervention, and the timing and results of the manipulation under anaesthesia (MUA) are under debate in the literature. Our aim was to determine the efficacy of single and multiple manipulations under anaesthesia following total knee arthroplasty and to determine the most appropriate timing for manipulation. We retrospectively reviewed 86 patients who underwent manipulation for stiffness following primary total knee replacement with at least 1-year follow-up. Range of motion before surgery, at the time of the MUA, immediately after MUA and at 6 weeks and 1 year post-MUA were recorded. At the end of 1 year post-manipulation, manipulations performed at less than 20 weeks, following primary total knee arthroplasty, showed 31° of flexion gain as compared to only 1.5° of flexion gain when manipulation was undertaken after 20 weeks. Of the 86 patients, 21 had multiple manipulations with no significant difference in flexion gain after the second manipulation. Patients on warfarin (26%) had an increased incidence of stiffness and poor flexion gain. This study showed that better results were achieved when manipulation was performed at less than 20 weeks (particularly between 12 and 14 weeks) from primary surgery with no added benefit from re-manipulations.
The high prevalence of pathologic calcium crystals in pre-operative knees.
Derfus, Beth A; Kurian, Jason B; Butler, Jeffrey J; Daft, Laureen J; Carrera, Guillermo F; Ryan, Lawrence M; Rosenthal, Ann K
2002-03-01
Calcium pyrophosphate dihydrate (CPPD) and basic calcium phosphate (BCP) crystals are important in the pathogenesis of osteoarthritis (OA) but are under recognized even in end stage disease. We determined the prevalence of these calcium crystals in synovial fluid (SF) of persons undergoing total knee arthroplasty for degenerative arthritis. SF samples were obtained from 53 knee joints undergoing total arthroplasty for a pre-operative diagnosis of OA. SF were analyzed via compensated light microscopy for CPPD crystals and a semiquantitative radiometric assay for BCP crystals. Fifty pre-operative radiographs were analyzed and graded according to the scale of Kellgren and Lawrence. Patients had an average age of 70 years at the time of surgery. CPPD and/or BCP crystals were identified in 60% of SF. Overall radiographic scores correlated with mean concentrations of BCP crystals. Higher mean radiographic scores correlated with the presence of calcium-containing crystals of either type in SF Radiographic chondrocalcinosis was identified in only 31% of those with SF CPPD. Pathologic calcium crystals were present in a majority of SF at the time of total knee arthroplasty. Intraoperative SF analysis could conveniently identify pathologic calcium crystals providing information that may be relevant to the future care of the patient's replaced joint and that of other joints. This information could also potentially aid in predicting the likelihood of the need for contralateral total knee arthroplasty.
Atraumatic haemarthrosis following total knee replacement treated with selective embolisation.
Karataglis, Dimitrios; Marlow, Duncan; Learmonth, Duncan J A
2006-06-01
Spontaneous haemarthrosis in the absence of anticoagulant medication or a bleeding disorder is a very rare complication after total knee arthroplasty. A case of recurrent spontaneous haemarthrosis following total knee replacement in a 69-year-old patient is reported. Angiography was used to aid the diagnosis. It demonstrated an abnormal blush of vessels around the anterior aspect of the knee joint, that was fed by genicular branches and a recurrent branch of the anterior tibial artery. Selective embolisation of the bleeding vessels with coils led to immediate control of the bleeding. No further recurrence of haemarthrosis has been recorded.
Utility of polymer cerclage cables in revision shoulder arthroplasty.
Edwards, T Bradley; Stuart, Kyle D; Trappey, George J; O'Connor, Daniel P; Sarin, Vineet K
2011-04-11
Revision shoulder arthroplasty often requires humeral osteotomy for stem extraction or is complicated by periprosthetic fracture. In these situations, various modes of fixation are used, including cerclage wires, cable plates, and allograft strut augmentation. The use of metal wires and cables, however, has been associated with soft tissue irritation, sharps injuries, and accelerated wear of joint arthroplasty bearing surfaces. As an alternative to traditional metal cables, the SuperCable (Kinamed Inc, Camarillo, California) contains braided ultra-high molecular-weight polyethylene fibers surrounding a nylon core. To date, no studies have examined the use of nonmetallic cerclage cables in shoulder arthroplasty.A retrospective review was performed of 11 patients who underwent shoulder arthroplasty for which nonmetallic cerclage cables were used. Clinical and radiographic data were examined regarding patient age, procedure performed, indication for cerclage cabling, time to healing of osteotomy or fracture, and any complications associated with the use of these cerclage cables. Minimum follow-up was 1 year. Ten patients underwent reverse total shoulder arthroplasty, and 1 patient underwent revision unconstrained total shoulder arthroplasty. Mean follow-up was 20.5 months. Ten patients required humeral osteotomy for stem or cement removal. Allograft augmentation was performed in 7 patients. Mean time to healing was 3.2 months. No patients experienced loosening or migration of hardware or allograft, and no complications directly related to the use of nonmetallic cerclage cables were identified. Copyright 2011, SLACK Incorporated.
Total hip arthroplasty in dwarfism. A case report.
De Fine, Marcello; Traina, Francesco; Palmonari, Massimo; Tassinari, Enrico; Toni, Aldo
2008-05-01
In dwarfism hip arthritis, usually secondary to hip dysplasia, is a common finding at an early age. In these patients a joint replacement is a demanding procedure due to the peculiar joint deformity and the small size of the bones. We present a case of a bilateral hip replacement in a dwarf patient. In order to reduce intraoperative complications and improve the joint kinematics a thorough preoperative planning was performed by a CT based computerised system. On the basis of the planning we chose a conical shaped stem that enable as to restore limb length and offset with a low risk of femoral fracture. In conclusion, we consider total hip replacement in dwarfism a safe and effective procedure if an accurate preoperative planning is performed.
Surgical difficulties for Total Knee Replacement in Stickler syndrome: A case report
Verma, Gopalkrishna G; Zarough, Adel; Suraliwala, KH
2008-01-01
Stickler syndrome is believed to be the most common connective tissue disorder in Europe and the USA. Severe osteoarthritis sets in at very early age in 3rd to 4th decade of life necessitating joint arthroplasty. This case report highlights the intraoperative surgical difficulties faced by the surgeon and the planning needed for the operation. PMID:18816376
Macmull, S; Bartlett, W; Miles, J; Blunn, G W; Pollock, R C; Carrington, R W J; Skinner, J A; Cannon, S R; Briggs, T W R
2010-12-01
Polymethyl methacrylate spacers are commonly used during staged revision knee arthroplasty for infection. In cases with extensive bone loss and ligament instability, such spacers may not preserve limb length, joint stability and motion. We report a retrospective case series of 19 consecutive patients using a custom-made cobalt chrome hinged spacer with antibiotic-loaded cement. The "SMILES spacer" was used at first-stage revision knee arthroplasty for chronic infection associated with a significant bone loss due to failed revision total knee replacement in 11 patients (58%), tumour endoprosthesis in four patients (21%), primary knee replacement in two patients (11%) and infected metalwork following fracture or osteotomy in a further two patients (11%). Mean follow-up was 38 months (range 24-70). In 12 (63%) patients, infection was eradicated, three patients (16%) had persistent infection and four (21%) developed further infection after initially successful second-stage surgery. Above knee amputation for persistent infection was performed in two patients. In this particularly difficult to treat population, the SMILES spacer two-stage technique has demonstrated encouraging results and presents an attractive alternative to arthrodesis or amputation. Copyright © 2009 Elsevier B.V. All rights reserved.
Strickland, Louise H; Kelly, Laura; Hamilton, Thomas W; Murray, David W; Pandit, Hemant G; Jenkinson, Crispin
2017-09-27
To explore the patients' perspective of surgery and early recovery when undergoing lower limb (hip or knee) arthroplasty. Lower limb arthroplasty is a commonly performed procedure for symptomatic arthritis, which has not responded to conservative medical treatment. Each patient's perspective of the surgical process and early recovery period impacts on their quality of life. Open, semistructured qualitative interviews were used to allow for a deeper understanding of the patient perspective when undergoing a hip or knee arthroplasty. Following ethical approval, 30 patients were interviewed between August and November 2016 during the perioperative period while undergoing an elective hip or knee arthroplasty (n = 30). The interviews were performed between the day of surgery and a nine-week postoperative clinic appointment. Data were analysed using an in-depth narrative thematic analysis method. NVivo qualitative data analysis software was used. Seven main themes evolved from the interviews: "improving function and mobility", "pain", "experiences of health care", "support from others", "involvement and understanding of care decisions", "behaviour and coping" and "fatigue and sleeping". The early postoperative recovery period is of vital importance to all surgical patients. This is no different for the orthopaedic patient. However, identifying key self-reported areas of importance from patients can guide clinical focus for healthcare professionals. To have specific patient-reported information regarding key areas of importance during the perioperative phase is invaluable when caring for the orthopaedic surgical patient. It gives insight and understanding in to this increasing population group. This study has also served as a starting point in the development of a questionnaire which could be used to assess interventions in the lower limb arthroplasty population. These results will influence both items and content of the questionnaire. © 2017 John Wiley & Sons Ltd.
Chung, Sang-Bong; Muradov, Johongir M; Lee, Sun-Ho; Eoh, Whan; Kim, Eun-Sang
2012-06-01
The purpose of this study is to investigate the incidence of heterotopic ossification (HO) in the Bryan cervical arthroplasty group and to identify associations between preoperative factors and the development of HO. We performed a retrospective review of clinical and radiological data on patients who underwent single-level cervical arthroplasty with Bryan prosthesis between January 2005 and September 2007. Patients were postoperatively followed-up at 1, 3, 6, 12 months and every year thereafter. The clinical assessment was conducted using Odom's criteria. The presence of HO was evaluated on the basis of X-ray at each time-point according to the McAfee classification. In this study, we focused on survivorship of Bryan prosthesis for single-level arthroplasty. The occurrence of ROM-affecting HO was defined as a functional failure and was used as an endpoint for determining survivorship. Through the analysis of 19 cases of Bryan disc arthroplasty for cervical radiculopathy and/or myelopathy, we revealed that ROM-affecting HO occurs in as many as 36.8% of cases and found that 37% of patients had ROM-affecting HO within 24 months following surgery. The overall survival time to the occurrence of ROM-affecting HO was 36.4 ± 4.4 months. Survival time of the prosthesis in the patient group without preoperative uncovertebral hypertrophy was significantly longer than that in the patient group with preoperative uncovertebral hypertrophy (47.2 months vs 25.5 months, p = 0.02). Cox regression proportional hazard analysis illustrated that preoperative uncovertebral hypertrophy was determined as a significant risk factor for the occurrence of ROM-affecting HO (hazard ratio = 12.30; 95% confidential interval = 1.10-137.03; p = 0.04). These findings suggest that the condition of the uncovertebral joint must be evaluated in preoperative planning for Bryan cervical arthroplasty.
Hua, Xijin; Li, Junyan; Wang, Ling; Wilcox, Ruth; Fisher, John; Jin, Zhongmin
2015-10-01
One important loosening mechanism of the cemented total hip arthroplasty is the mechanical overload at the bone-cement interface and consequent failure of the cement fixation. Clinical studies have revealed that the outer diameter of the acetabular component is a key factor in influencing aseptic loosening of the hip arthroplasty. The aim of the present study was to investigate the influence of the cup outer diameter on the contact mechanics and cement fixation of a cemented total hip replacement (THR) with different wear penetration depths and under different cup inclination angles using finite element (FE) method. A three-dimensional FE model was developed based on a typical Charnley hip prosthesis. Two acetabular cup designs with outer diameters of 40 and 43 mm were modelled and the effect of cup outer diameter, penetration depth and cup inclination angle on the contact mechanics and cement fixation stresses in the cemented THR were studied. The results showed that for all penetration depths and cup inclination angles considered, the contact mechanics in terms of peak von Mises stress in the acetabular cup and peak contact pressure at the bearing surface for the two cup designs were similar (within 5%). However, the peak von Mises stress, the peak maximum principal stress and peak shear stress in the cement mantle at the bone-cement interface for the 43 mm diameter cup design were predicted to be lower compared to those for the 40 mm diameter cup design. The differences were predicted to be 15-19%, 15-22% and 18-20% respectively for different cup penetration depths and inclination angles, which compares to the clinical difference of aseptic loosening incidence of about 20% between the two cup designs. Copyright © 2015 IPEM. Published by Elsevier Ltd. All rights reserved.
Schill, Stephan
2007-12-01
Restoration of painless function to the lower limb by ankle fusion after failure of total ankle arthroplasty. Loose total ankle replacement. Severe ankle destruction and axial deviation in rheumatoid patients. Severe osteoarthritis in the subtalar and ankle joints. Infected total ankle replacement. Severe arterial occlusive disease of the affected extremity. Transfibular approach to the subtalar and ankle joints. Osteotomy and resection of the distal fibula 7-8 cm proximal to the tip of the lateral malleolus. Removal of the prosthetic components, synovectomy, and revitalization of the remaining bone surface. Removal of any residual articular cartilage from the subtalar joint surfaces. Determination of the extent of bone loss and defect filling with horizontally or vertically placed tricortical and cancellous bone graft from the resected fibula and, if necessary, from the ipsilateral anterior iliac crest. Tibiotalocalcaneal arthrodesis by retrograde insertion of a retrograde locking nail. Wound closure in layers. Split below-knee cast. Mobilization with below-knee cast without weight bearing for 6 weeks. Dynamic locking of the intramedullary nail. Partial weight bearing with a walker up to 20 kg for an additional 6 weeks. Gradual increase in weight bearing in accordance with radiologic evidence of consolidation. Fitted orthopedic shoe with rocker-bottom sole, and made to measure insoles. From January 2003 to September 2006, 15 patients with infected ankle prosthesis loosening (six Thompson-Richards prostheses, eight S.T.A.R. prostheses, and one Salto prosthesis) were treated. All patients underwent tibiotalocalcaneal interposition arthrodesis with femoral nailing in retrograde technique. The average AOFAS (American Orthopaedic Foot and Ankle Society) Score was 57.9 points (35-81 points) postoperatively. One patient developed a nonunion and revision surgery will have to be performed. Another patient with delayed wound healing and skin necrosis needed plastic surgery.
Komnik, Igor; David, Sina; Weiss, Stefan; Potthast, Wolfgang
2016-01-01
After knee arthroplasty (KA) surgery, patients experience abnormal kinematics and kinetics during numerous activities of daily living. Biomechanical investigations have focused primarily on level walking, whereas walking on sloped surfaces, which is stated to affect knee kinematics and kinetics considerably, has been neglected to this day. This study aimed to analyze over-ground walking on level and sloped surfaces with a special focus on transverse and frontal plane knee kinematics and kinetics in patients with KA. A three-dimensional (3D) motion analysis was performed by means of optoelectronic stereophogrammetry 1.8 ± 0.4 years following total knee arthroplasty (TKA) and unicompartmental arthroplasty surgery (UKA). AnyBody™ Modeling System was used to conduct inverse dynamics. The TKA group negotiated the decline walking task with reduced peak knee internal rotation angles compared with a healthy control group (CG). First-peak knee adduction moments were diminished by 27% (TKA group) and 22% (UKA group) compared with the CG during decline walking. No significant differences were detected between the TKA and UKA groups, regardless of the locomotion task. Decline walking exposed apparently more abnormal knee frontal and transverse plane adjustments in KA patients than level walking compared with the CG. Hence, walking on sloped surfaces should be included in further motion analysis studies investigating KA patients in order to detect potential deficits that might be not obvious during level walking. PMID:28002437
Total knee arthroplasty in limbs affected by poliomyelitis.
Giori, Nicholas J; Lewallen, David G
2002-07-01
Little information is available regarding the results and complications of total knee arthroplasty in limbs affected by poliomyelitis with severe knee degeneration. We performed a retrospective chart and radiograph review of patients with a history of poliomyelitis involving a limb that subsequently underwent primary total knee arthroplasty between 1970 and 2000. Sixteen total knee arthroplasties were performed in limbs affected by poliomyelitis in fifteen patients. Eleven patients were followed for a minimum of two years, one (two knees) died before the minimum two-year follow-up could be completed, and three were followed for less than two years. No patient was lost to follow-up. There were two periprosthetic fractures, one peroneal nerve palsy, one avulsion of the patellar tendon, and four cases of recurrent instability. These complications were related to the poor bone quality, valgus deformity, patella baja, poor musculature, and attenuated soft tissues commonly found in knees affected by poliomyelitis. Knee Society pain and knee scores were improved postoperatively for all nine knees with a two-year follow-up that had had at least antigravity quadriceps strength prior to surgery. However, Knee Society function scores remained at 0 or worsened for six of the eleven knees followed for at least two years, including those with less than antigravity strength, and four of the nine knees with at least antigravity strength. None of the prostheses loosened. Pain and knee scores improved following total knee arthroplasty in patients with a history of poliomyelitis and antigravity quadriceps strength, but there was less pain relief in patients with less than antigravity quadriceps strength. Recurrence of instability and progressive functional deterioration is possible in all knees affected by poliomyelitis that have undergone total knee replacement, but they appear to occur more commonly in more severely affected knees.
Pabinger, C; Berghold, A; Boehler, N; Labek, G
2013-02-01
To assess revision rates after knee arthroplasty by comparing the cumulative results from worldwide clinical studies and arthroplasty registers. We hypothesised that the revision rate of all clinical studies of a given implant and register data would not differ significantly. A systematic review of clinical studies in indexed peer-reviewed journals was performed followed by internal and external validation. Parameters for measurement of revision were applied (Revision for any reason, Revisions per 100 observed component years). Register data served as control group. Thirty-six knee arthroplasty systems were identified to meet the inclusion criteria: 21 total knee arthroplasty (TKA) systems, 14 unicondylar knee arthroplasty (UKA) systems, one patello-femoral implant system. For 13 systems (36%), no published study was available that contained revision data. For 17 implants (47%), publications were available dealing with radiographic, surgical or technical details, but power was too weak to compare revision rates at a significant level. Six implant systems (17%) had a significant number of revisions published and were finally analysed. In general, developers report better results than independent users. Studies from developers represent an overproportional share of all observed component years. Register data report overall 10-year revision rates of TKA of 6.2% (range: 4.9-7.8%), rates for UKA are 16.5% (range: 9.7-19.6%). Revision rates of all clinical studies of a given implant do not differ significantly from register data. However, significant differences were found between the revision rates published by developers and register data. Therefore the different data need to be interpreted in the context of the source of the information. Copyright © 2012 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.
Early outcomes of patella resurfacing in total knee arthroplasty
Clements, Warren J; Miller, Lisa; Whitehouse, Sarah L; Graves, Stephen E; Ryan, Philip
2010-01-01
Background Patella resurfacing in total knee arthroplasty is a contentious issue. The literature suggests that resurfacing of the patella is based on surgeon preference, and little is known about the role and timing of resurfacing and how this affects outcomes. Methods We analyzed 134,799 total knee arthroplasties using data from the Australian Orthopaedic Association National Joint Replacement Registry. Hazards ratios (HRs) were used to compare rates of early revision between patella resurfacing at the primary procedure (the resurfacing group, R) and primary arthroplasty without resurfacing (no-resurfacing group, NR). We also analyzed the outcomes of NR that were revised for isolated patella addition. Results At 5 years, the R group showed a lower revision rate than the NR group: cumulative per cent revision (CPR) 3.1% and 4.0%, respectively (HR = 0.75, p < 0.001). Revisions for patellofemoral pain were more common in the NR group (17%) than in the R group (1%), and “patella only” revisions were more common in the NR group (29%) than in the R group (6%). Non-resurfaced knees revised for isolated patella addition had a higher revision rate than patella resurfacing at the primary procedure, with a 4-year CPR of 15% and 2.8%, respectively (HR = 4.1, p < 0.001). Interpretation Rates of early revision of primary total knees were higher when the patella was not resurfaced, and suggest that surgeons may be inclined to resurface later if there is patellofemoral pain. However, 15% of non-resurfaced knees revised for patella addition are re-revised by 4 years. Our results suggest an early beneficial outcome for patella resurfacing at primary arthroplasty based on revision rates up to 5 years. PMID:19968604
Eslam Pour, Aidin; Bradbury, Thomas L; Horst, Patrick K; Harrast, John J; Erens, Greg A; Roberson, James R
2016-07-01
A certified list of all operative cases performed within a 6-month period is a required prerequisite for surgeons taking the American Board of Orthopaedic Surgery Part II oral examination. Using the American Board of Orthopaedic Surgery secure Internet database database containing these cases, this study (1) assessed changing trends for primary and revision total hip arthroplasty (THA) and (2) compared practices and early postoperative complications between 2 groups of examinees, those with and without adult reconstruction fellowship training. Secure Internet database was searched for all 2003-2013 procedures with a Current Procedural Terminology code for THA, hip resurfacing, hemiarthroplasty, revision hip arthroplasty, conversion to THA, or removal of hip implant (Girdlestone, static, or dynamic spacer). Adult reconstruction fellowship-trained surgeons performed 60% of the more than 33,000 surgeries identified (average 28.1) and nonfellowship-trained surgeons performed 40% (average 5.2) (P < .001). Fellowship-trained surgeons performed significantly more revision surgeries for infection (71% vs 29%)(P < .001). High-volume surgeons had significantly fewer complications in both primary (11.1% vs 19.6%) and revision surgeries (29% vs 35.5%) (P < .001). Those who passed the Part II examination reported higher rates of complications (21.5% vs 19.9%). In early practice, primary and revision hip arthroplasties are often performed by surgeons without adult reconstruction fellowship training. Complications are less frequently reported by surgeons with larger volumes of joint replacement surgery who perform either primary or more complex cases. Primary hip arthroplasty is increasingly performed by surgeons early in practice who have completed an adult reconstructive fellowship after residency training. This trend is even more pronounced for more complex cases such as revision or management of infection. Copyright © 2016 Elsevier Inc. All rights reserved.
Geeske Peeters, G M E E; Rainbird, Sophia; Lorimer, Michelle; Dobson, Annette J; Mishra, Gita D; Graves, Stephen E
2017-04-01
Background and purpose - There are concerns that mental health (MH) may influence outcomes of total knee arthroplasty (TKA) or total hip arthroplasty (THA). We examined effects of poor MH before surgery on long-term outcomes of osteoarthritis-related TKA or THA in women. Patients and methods - The data were from 9,737 middle-aged participants (47-52 years) and 9,292 older participants (73-78 years) in the Australian Longitudinal Study on Women's Health who completed surveys between 1998 and 2013. Dates of arthroplasties were obtained from the Australian Orthopaedics Association National Joint Replacement Registry. Participants without procedures were matched with participants with procedures. Trajectories of the Short-Form 36 scores for physical functioning, bodily pain, social functioning, and mental health based on mixed modeling were plotted for participants with and without surgery (stratified according to mental health, separately for TKA and THA, and for middle-aged and older participants). Results - In middle-aged women with poor and good MH, TKA improved physical function and reduced bodily pain, with improvements sustained up to 10 years after surgery. TKA contributed to restoration of social function in women with good MH, but this was less clear in women with poor MH. In both MH groups, mental health appeared to be unaffected by TKA. Similar patterns were observed after THA, and in older women. Interpretation - Recovery of physical and social function and reductions in pain were sustained for up to 10 years after surgery. Improvements in physical function and pain were also observed in women with poor mental health. Thus, in our view poor mental health should not be a contraindication for arthroplasty.
Short-term clinical experience with hip resurfacing arthroplasty.
Cieliński, Łukasz; Kusz, Damian; Wojciechowski, Piotr; Dziuba, Anna
2007-01-01
This paper discusses the authors' experience with hip resurfacing arthroplasty. Although introduced many years ago, the method did not gain wide popularity because of poor long-term outcomes. At present, owing to the introduction of metal-on-metal bearings and hybrid fixation techniques, short- and mid-term results are very good and encourage wider use of this technique, especially in the younger and more active patients whose results with standard total hip replacements would be unsatisfactory. We performed 13 hip resurfacing arthroplasties at our institution between August 1, 2005, and May 1, 2006. Twelve patients reported for the scheduled follow-up and were included in the study. Treatment outcomes were assessed according to the Harris Hip Score. The short-term outcomes of hip resurfacing arthroplasties are encouraging. In the study group there were no intraoperative complications, infections, peripheral nerve palsy, hip dislocations or clinically overt vein thrombosis. All of the patients reported complete or major pain relief. Clinical assessment according to the Harris Hip Score revealed improvement from an average of 57.7 (20.1) points preoperatively to an average of 87.7 (12) points after the surgery. Crutches were used for a maximum of 6 weeks postoperatively. All of the patients are currently able to walk without crutches with full weight-bearing. 1) Hip resurfacing arthroplasty seems to be an advisable method of operative management of younger, active patients, in whom standard THR would be associated with a high risk of failure; it allows THR to be postponed and carried out as a revision surgery with the acetabular component already in place. 2) Despite the good short- and mid-term results, the utility of this method should be evaluated with caution due to the lack of adequate long-term follow-up data.
Risk factors for total hip arthroplasty aseptic revision.
Khatod, Monti; Cafri, Guy; Namba, Robert S; Inacio, Maria C S; Paxton, Elizabeth W
2014-07-01
The purpose of this study was to evaluate patient, operative, implant, surgeon, and hospital factors associated with aseptic revision after primary THA in patients registered in a large US Total Joint Replacement Registry. A total of 35,960 THAs registered from 4/2001-12/2010 were evaluated. The 8-year survival rate was 96.7% (95% CI 96.4%-97.0%). Females had a higher risk of aseptic revision than males. Hispanic and Asian patients had a lower risk of revision than white patients. Ceramic-on-ceramic, ceramic-on-conventional polyethylene, and metal-on-conventional polyethylene bearing surfaces had a higher risk of revision than metal-on-highly cross-linked polyethylene. Body mass index, health status, diabetes, diagnosis, fixation, approach, bilateral procedures, head size, surgeon fellowship training, surgeon and hospital volume were not revision risk factors. Copyright © 2014 Elsevier Inc. All rights reserved.
Physiotherapy-led arthroplasty review clinic: a preliminary outcomes analysis.
Large, Kate E; Page, Carolyn J; Brock, Kim; Dowsey, Michelle M; Choong, Peter F M
2014-11-01
With the rising demand for Orthopaedics in the healthcare sector, service delivery innovations need to be explored to accommodate the increasing workload. Senior Musculoskeletal Physiotherapists have the specialised skills in the assessment of musculoskeletal conditions to determine the impact of surgery on patient outcomes. The aim of the present study was to compare outcomes between a physiotherapy-led arthroplasty review clinic (PT clinic) and the traditional model of orthopaedic surgeon review (OS clinic) after hip and knee replacement. This study was a retrospective case-controlled audit using a comprehensive database. Twenty-four patients who had a hip arthroplasty and 52 patients who had a knee arthroplasty were reviewed solely by the PT clinic at 3, 6 and 12 months after surgical reviews. These patients were matched 1:2 against patients seen only by the OS clinic. The outcome measures included International Knee Score (IKS), Harris Hip Score (HHS) and the Short Form (SF)-12. There were no significant differences in HHS or SF-12 scores for patients after hip arthroplasty. Significant differences for knee arthroplasty were observed favouring the PT clinic; IKS, PT clinic 147.6 (37.07), OS clinic 135.4 (35.68), P≤0.01, and physical component of the SF-12, PT clinic 41.98 (10.45), OS clinic 37.20 (10.44), P<0.01. Implementation of a physiotherapy-led arthroplasty review clinic appears to be a safe and effective service alternative to reviews conducted by orthopaedic surgeons. WHAT IS KNOWN ABOUT THE TOPIC?: Osteoarthritis (OA) is a leading cause of musculoskeletal pain and disability and the burden of the disease is rapidly increasing. Joint arthroplasty surgery is the mainstay of treatment for people with end-stage OA; it is a high-cost, high-volume procedure that dominates surgical wait lists around Australia. Long-term follow up is encouraged by the Arthroplasty Society of Australia and endorsed by the Australian Orthopaedics Association, but it is acknowledged that it is impossible to achieve this with solely orthopaedic surgeon reviews, an issue that is only going to worsen with the increased demand for surgery. Physiotherapists have become involved in many advanced scope roles within public health care, and emerging research suggests that patients are highly satisfied with their care in these types of clinics. WHAT DOES THIS PAPER ADD?: Although it has been shown that patients are satisfied in physiotherapy-led advanced clinics, there is a paucity of evidence in the outcomes of patients attending these clinics. Implementation of a physiotherapy-led arthroplasty review clinic demonstrated that outcome measures in this patient cohort were not compromised and, following knee joint arthroplasty, may even be improved. WHAT ARE THE IMPLICATIONS FOR PRACTITIONERS?: The findings of this study indicate that joint review clinics involving physiotherapists acting in an advanced scope role are unlikely to compromise patient outcomes. The use of this role substitution on a broader scale can be recommended.
2007-01-01
Background The US Food and Drug Administration approved the Charité artificial disc on October 26, 2004. This approval was based on an extensive analysis and review process; 20 years of disc usage worldwide; and the results of a prospective, randomized, controlled clinical trial that compared lumbar artificial disc replacement to fusion. The results of the investigational device exemption (IDE) study led to a conclusion that clinical outcomes following lumbar arthroplasty were at least as good as outcomes from fusion. Methods The author performed a new analysis of the Visual Analog Scale pain scores and the Oswestry Disability Index scores from the Charité artificial disc IDE study and used a nonparametric statistical test, because observed data distributions were not normal. The analysis included all of the enrolled subjects in both the nonrandomized and randomized phases of the study. Results Subjects from both the treatment and control groups improved from the baseline situation (P < .001) at all follow-up times (6 weeks to 24 months). Additionally, these pain and disability levels with artificial disc replacement were superior (P < .05) to the fusion treatment at all follow-up times including 2 years. Conclusions The a priori statistical plan for an IDE study may not adequately address the final distribution of the data. Therefore, statistical analyses more appropriate to the distribution may be necessary to develop meaningful statistical conclusions from the study. A nonparametric statistical analysis of the Charité artificial disc IDE outcomes scores demonstrates superiority for lumbar arthroplasty versus fusion at all follow-up time points to 24 months. PMID:25802574
Perazzo, Paolo; Viganò, Marco; de Girolamo, Laura; Verde, Francesco; Vinci, Anna; Banfi, Giuseppe; Romagnoli, Sergio
2013-01-01
Background Blood loss during total joint arthroplasty strongly influences the time to recover after surgery and the quality of the recovery. Blood conservation strategies such as pre-operative autologous blood donation and post-operative cell salvage are intended to avoid allogeneic blood transfusions and their associated risks. Although widely investigated, the real effectiveness of these alternative transfusion practices remains controversial. Materials and methods The surgery reports of 600 patients undergoing total joint arthroplasty (312 hip and 288 knee replacements) were retrospectively reviewed to assess transfusion needs and related blood management at our institute. Evaluation parameters included post-operative blood loss, haemoglobin concentration measured at different time points, ASA score, and blood transfusion strategies. Results Autologous blood donation increased the odds of receiving a red blood cell transfusion. Reinfusion by a cell salvage system of post-operative shed blood was found to limit adverse effects in cases of severe post-operative blood loss. The peri-operative net decrease in haemoglobin concentration was higher in patients who had predeposited autologous blood than in those who had not. Discussion The strengths of this study are the high number of cases and the standardised procedures, all operations having been performed by a single orthopaedic surgeon and a single anaesthesiologist. Our data suggest that a pre-operative autologous donation programme may often be useless, if not harmful. Conversely, the use of a cell salvage system may be effective in reducing the impact of blood transfusion on a patient’s physiological status. Basal haemoglobin concentration emerged as a useful indicator of transfusion probability in total joint replacement procedures. PMID:23736922
Boutault, F; Cavallier, Z; Lauwers, F; Prevost, A
2018-06-01
To evaluate mid-term results from using a silicone sheet for inter-positional arthroplasty in moderate or severe cases of osteoarthrosis of the temporo-mandibular joint (TMJ). To also determine any remaining indications from this method. This retrospective study included patients that underwent surgery between 2008 and 2016. Pre- and post-operative mouth opening (MO), according to inter-incisal distance (mm) and pain score (PS: 0=no pain to 4=very severe pain) were recorded for 24 patients. Patients were divided according to thickness of the silicone sheet (group A: 1.0 mm, group B: 1.5 mm). The cohort included 22 females (92%). Mean age at surgery was 55 years±13 (26-80). Mean length of follow-up was 26 months±24 (6-80). Mean improvement in MO was 8.2 mm (+33%) and of PS was 1.7 (-68%). MO was not improved for two patients and worsened for one. PS score improved for all patients. No statistical difference was found between groups A and B. There was also a tendency for degradation of outcomes over time. The poor reputation of prosthetic discoplasty was not as evident in our series, even though anatomical and functional status seemed to deteriorate over time. This is because total-joint prosthetic replacement is often proposed instead. However, for elderly or fragile patients that have severe pain, and regarding cost-benefit aspects, conventional arthroplasty can still be discussed, especially since French national health-care insurance does not yet support TMJ prosthetic replacement for osteoarthrosis. Copyright © 2018 Elsevier Masson SAS. All rights reserved.
Comparison of thromboprophylaxis patterns in arthroplasty in public and private hospitals
Cortada, Aline Pinheiro dos Santos; da Silva, Telma Gomes; da Silva, André Campos; Golmia, Ricardo Prado; Guerra, Renata Leborato; Takemoto, Maíra Libertad Soligo; Monteiro, Roberta Dyonisio Canaveira; Scheinberg, Morton Aaron
2015-01-01
Objective To compare therapy for prophylaxis of venous thromboembolism and costs related to hospitalization of patients undergoing total knee and hip replacement within the context of the Brazilian health system. Methods A retrospective study of patients undergoing arthroplasty in 2010 in a public hospital and two private hospitals in the state of São Paulo, conducted by means of medical record review. Costs were estimated based on the use of health care resources during hospitalization. A descriptive analysis was performed using frequency and mean (standard deviation) according to the type of care delivered (by public or private organization). Results A total of 215 patients were evaluated, and 56.3% were submitted to knee surgery and 43.7%, to hip replacement. Approximately 88% and 98% of patients from public and private health services, respectively, received some form of venous thromboembolism prophylaxis, and enoxaparin was the drug most widely used in both systems. The total cost of prophylaxis was R$ 1,873.01 (R$ 26.38 per patient) in the public service and R$ 21,559.73 (R$ 163.33 per patient) in the private service. For the individuals who presented with thromboembolism, the average cost of hospitalization was R$ 6,210.80 and R$ 43,792.59 per patient in public and private health services, respectively. Conclusion Thromboembolism prophylaxis in patients undergoing arthroplasty is most commonly used in the private health services than public organizations, despite its high costs in both services. The cost per patient with thrombosis during hospitalization was higher than the total cost of prophylaxis, suggesting that prevention is associated to better cost-benefit ratio. PMID:26313439
Weeks, William B; Schoellkopf, William J; Ballard, David J; Kaplan, Gary S; James, Brent; Weinstein, James N
2017-06-01
To inform consumers and restrain health care cost growth, efforts to promote transparency and to reimburse for care episodes are accelerating in the United States. To compare characteristics and costs of 30-day episode of care for hip and knee replacement occurring in High Value Healthcare Collaborative (HVHC)-member hospitals to those occurring in like non-HVHC-member hospitals in the same 15 health care markets before interventions by HVHC members to improve health care value for those interventions. This is a retrospective analysis of fee-for-service Medicare data from 2012 and 2013. For hip arthroplasty, 4030 HVHC-member and 7572 non-HVHC-member, and for knee arthroplasty, 6542 HVHC-member and 13,900 non-HVHC-member fee-for-service Medicare patients aged 65 and older. Volumes, patient demographics, hospital stay characteristics, and acute and postacute care standardized costs for a 30-day episode of care. HVHC-member hospitals differed from similar non-HVHC-member hospitals in the same health care markets when considering volumes of surgeries, patient demographics, Charlson scores, and patient distance to care during the index admission. There was little variation in acute care costs of hip or knee replacement surgery across health care markets; however, there was substantial variation in postacute care costs across those same markets. We saw less variation in postacute care costs within markets than across markets. Regression analyses showed that HVHC-member status was not associated with shorter lengths of stay, different complication rates, or lower total or postacute care costs for hip or knee replacement. Health care regions appear to be a more important predictor of episode costs of care than HVHC status.
Baker, Paul; Coole, Carol; Drummond, Avril; McDaid, Catriona; Khan, Sayeed; Thomson, Louise; Hewitt, Catherine; McNamara, Iain; McDonald, David; Fitch, Judith; Rangan, Amar
2018-06-28
There are an increasing number of patients of working age undergoing hip and knee replacements. Currently there is variation in the advice and support given about sickness absence, recovery to usual activities and return to work after these procedures. Earlier, sustainable, return to work improves the health of patients and benefits their employers and society. An intervention that encourages and supports early recovery to usual activities, including work, has the potential to reduce the health and socioeconomic burden of hip and knee replacements. A two-phase research programme delivered over 27 months will be used to develop and subsequently test the feasibility of an occupational advice intervention to facilitate return to work and usual activities in patients undergoing lower limb arthroplasty. The 2 phases will incorporate a six-stage intervention mapping process: Phase 1: Intervention mapping stages 1-3: 1 Needs assessment (including rapid evidence synthesis, prospective cohort analysis and structured stakeholder interviews) 2 Identification of intended outcomes and performance objectives 3 Selection of theory-based methods and practical strategies Phase 2: Intervention mapping stages 4-6: 4 Development of components and materials for the occupational advice intervention using a modified Delphi process 5 Adoption and implementation of the intervention 6 Evaluation and feasibility testing The study will be undertaken in four National Health Service (NHS) hospitals in the United Kingdom and two Higher Education Institutions. OPAL (Occupational advice for Patients undergoing Arthroplasty of the Lower limb) aims to develop an occupational advice intervention to support early recovery to usual activities including work, which is tailored to the requirements of patients undergoing hip and knee replacements. The developed intervention will then be assessed with a specific focus on evaluating its feasibility as a potential trial intervention to improve speed of recovery to usual activities including work. The study was registered retrospectively with the International Standard Randomised Controlled Trials Number (ISRCTN): 27426982 (Date 20/12/2016) and the International prospective register of systematic reviews (PROSPERO): CRD42016045235 (Date 04/08/2016).
A2-3: Impact of Mild Chronic Kidney Disease Stage on Outcomes after Total Hip or Knee Arthroplasty
Graham, Jove; Deegan, Brian; Bowen, Thomas; Richard, Raveesh; Perkins, Robert; Foltzer, Michael
2014-01-01
Background/Aims Dialysis and kidney transplantation adversely impact outcomes of total hip or knee arthroplasty (THA, TKA), but complication rates have not been reported for patients with less advanced stages of chronic kidney disease (CKD). Surgeons lack the data necessary to have informed discussions regarding anticipated outcomes of joint replacement for these patients. Methods We retrospectively reviewed electronic health records of 779 adults with stages 1, 2, and 3 CKD not requiring dialysis or transplantation who underwent THA or TKA from 2004–2011, to assess infection, revision, 90-day readmission and mortality rates. Patients with less than 12 months follow-up, open fracture, prior joint surgery, pregnancy, or acute kidney injury were excluded. Chi-square analysis and Cox survival analysis compared these outcomes between the stage 1–2 and stage 3 groups, stratified by joint replaced (THA vs TKA). All models adjusted for age, sex and BMI at surgery. Results No statistically different rates of revision or infection between Stage 3 vs. Stages 1–2 were seen, although there was a trend toward increased infections in Stage 3. THA patients with Stage 3 showed a significantly increased mortality rate compared to Stage 1–2 THA patients (HR 3.40, 95% CI = 1.25–9.23, P = 0.02). Conclusions CKD affects nearly 15% of the U.S. population many of whom undergo joint replacement. End stage kidney disease (patients post-transplant or on hemodialysis) has been consistently associated with increased rates of infection and revision in excess of our observed outcomes, but the overall rate of infection/revision in our study population was only slightly higher than reported rates in the general population (2–7% vs. 1–2%, respectively). CKD should not preclude joint replacement, but these data can help clinicians engage in meaningful informed discussions with patients with mild kidney disease regarding risks for infection, revision and death following joint replacement.
Smith, Holly; Jan, Meryam; Mahomed, Nizar N; Davey, J Rod; Gandhi, Rajiv
2011-12-01
Mobile bearing (MB) knee replacements were designed with the goal of increased conformity and decreased bearing wear. We conducted a meta-analysis and systematic review of randomized controlled trials comparing outcomes of MB and fixed bearing (FB) total knee arthroplasty (TKA). We identified 14 studies reporting our primary outcome of Knee Society Scores (KSS). We also pooled data for post-operative range of motion (ROM) and Hospital for Special Surgery scores (HSS). The standard difference in mean outcome scores for KSS and HSS demonstrated no difference between groups (P = .902, and P = .426 respectively). Similarly, the pooled data for ROM showed no difference between groups (P = .265). The results of this study found no significant differences between clinical outcomes of MB and FB TKA. Copyright © 2011 Elsevier Inc. All rights reserved.
Sabeh, Karim G; Rosas, Samuel; Buller, Leonard T; Roche, Martin W; Hernandez, Victor H
2017-10-01
Total joint arthroplasty (TJA) accounts for more Medicare expenditure than any other inpatient procedure. The Comprehensive Care for Joint Replacement model was introduced to decrease cost and improve quality in TJA. The largest portion of episode-of-care costs occurs after discharge. This study sought to quantify the cost variation of primary total hip arthroplasty (THA) according to discharge disposition. The Medicare and Humana claims databases were used to extract charges and reimbursements to compare day-of-surgery and 91-day postoperative costs simulating episode-of-care reimbursements. Of the patients who underwent primary THA, 257,120 were identified (204,912 from Medicare and 52,208 from Humana). Patients were stratified by discharge disposition: home with home health, skilled nursing facility, or inpatient rehabilitation facility. There is a significant difference in the episode-of-care costs according to discharge disposition, with discharge to an inpatient rehabilitation facility the most costly and discharge to home the least costly. Postdischarge costs represent a sizeable portion of the overall expense in THA, and optimizing patients to allow safe discharge to home may help reduce the cost of THA. Copyright © 2017 Elsevier Inc. All rights reserved.
The risks of splash injury when using power tools during orthopaedic surgery: a prospective study.
Alani, Asef; Modi, Cheaten; Almedghio, Sami; Mackie, Ian
2008-10-01
Transmissible blood-borne infection can occur at muco-cutaneous membranes. During trauma and orthopaedic surgery, the use of power tools increases spraying of bodily fluid, hence resulting in an increased risk of infectious splash injury to the face. This prospective study involved 25 patients. The visors worn by the operating team were examined postoperatively to identify any visible blood, fat and body tissue splashes. Eleven patients underwent knee arthroplasty. Splash counts to the surgeon's mouth/lip, nose/cheek and eye regions were 217, 105, and 62 respectively; they were 258, 147, and 82 for the assistant. Fourteen patients had hip replacement; splash counts to the surgeon's mouth/lip, nose/cheek and eye regions were 214, 90, and 53 respectively, and 137, 39 and 27 for the assistant. To conclude, the face is vulnerable to material and fluid strikes during joint arthroplasty surgery. The visor is a reliable barrier to blood, fat and body tissue splashes and minimises the risk of exposure to blood-borne viruses. Therefore, a visor should be worn during all joint arthroplasty procedures and any procedure that involves the use of power tools.
Thomas, Peter; von der Helm, Christine; Schopf, Christoph; Mazoochian, Farhad; Frommelt, Lars; Gollwitzer, Hans; Schneider, Josef; Flaig, Michael; Krenn, Veit; Thomas, Benjamin; Summer, Burkhard
2015-01-01
We performed a combined approach to identify suspected allergy to knee arthroplasty (TKR): patch test (PT), lymphocyte transformation test (LTT), histopathology (overall grading; T- and B-lymphocytes, macrophages, and neutrophils), and semiquantitative Real-time-PCR-based periprosthetic inflammatory mediator analysis (IFNγ, TNFα, IL1-β, IL-2, IL-6, IL-8, IL-10, IL17, and TGFβ). We analyzed 25 TKR patients with yet unexplained complications like pain, effusion, and reduced range of motion. They consisted of 20 patients with proven metal sensitization (11 with PT reactions; 9 with only LTT reactivity). Control specimens were from 5 complicated TKR patients without metal sensitization, 12 OA patients before arthroplasty, and 8 PT patients without arthroplasty. Lymphocytic infiltrates were seen and fibrotic (Type IV membrane) tissue response was most frequent in the metal sensitive patients, for example, in 81% of the PT positive patients. The latter also had marked periprosthetic IFNγ expression. 8/9 patients with revision surgery using Ti-coated/oxinium based implants reported symptom relief. Our findings demonstrate that combining allergy diagnostics with histopathology and periprosthetic cytokine assessment could allow us to design better diagnostic strategies.
Infected total knee arthroplasty treated with arthrodesis using a modular nail.
Waldman, B J; Mont, M A; Payman, K R; Freiberg, A A; Windsor, R E; Sculco, T P; Hungerford, D S
1999-10-01
Failed treatment of infected total knee replacement presents few attractive surgical options. Knee arthrodesis is challenging surgically and can be complicated by nonunion, malunion, or recurrent infection. Recently, a modular titanium intramedullary nail has been used in an attempt to reduce the incidence of nonunion and the rate of complications. In the present study, a review of the results of knee arthrodesis after infected total knee arthroplasty in 21 patients at three large academic institutions was performed. All patients were followed up for a mean of 2.4 years (range, 2-7.5 years). The mean age of the patients was 64 years. The mean number of previous operations was four (range, 2-9 operations). A solid arthrodesis was achieved without additional surgical treatment in 20 of 21 patients (95%). The mean time to fusion was 6.3 months. The one patient who suffered a nonunion achieved fusion after a subsequent bone grafting procedure. Based on the present study, intramedullary arthrodesis with a coupled titanium nail, is a reliable, effective method of achieving fusion after infection of a total knee arthroplasty. This procedure resulted in a high rate of fusion and a lower rate of complications when compared with traditional methods of arthrodesis.
Booker, Simon; Alfahad, Nawaf; Scott, Martin; Gooding, Ben; Wallace, W Angus
2015-01-01
To investigate shoulder scoring systems used in Europe and North America and how outcomes might be classified after shoulder joint replacement. All research papers published in four major journals in 2012 and 2013 were reviewed for the shoulder scoring systems used in their published papers. A method of identifying how outcomes after shoulder arthroplasty might be used to categorize patients into fair, good, very good and excellent outcomes was explored using the outcome evaluations from patients treated in our own unit. A total of 174 research articles that were published in the four journals used some form of shoulder scoring system. The outcome from shoulder arthroplasty in our unit has been evaluated using the constant score (CS) and the oxford shoulder score and these scores have been used to evaluate individual patient outcomes. CSs of < 30 = unsatisfactory; 30-39 = fair; 40-59 = good; 60-69 = very good; and 70 and over = excellent. The most popular shoulder scoring systems in North America were Simple Shoulder Test and American shoulder and elbow surgeons standard shoulder assessment form score and in Europe CS, Oxford Shoulder Score and DASH score. PMID:25793164
Prometheus payment model: application to hip and knee replacement surgery.
Rastogi, Amita; Mohr, Beth A; Williams, Jeffery O; Soobader, Mah-Jabeen; de Brantes, Francois
2009-10-01
The Prometheus Payment Model offers a potential solution to the failings of the current fee-for-service system and various forms of capitation. At the core of the Prometheus model are evidence-informed case rates (ECRs), which include a bundle of typical services that are informed by evidence and/or expert opinion as well as empirical data analysis, payment based on the severity of patients, and allowances for potentially avoidable complications (PACs) and other provider-specific variations in payer costs. We outline the methods and findings of the hip and knee arthroplasty ECRs with an emphasis on PACs. Of the 2076 commercially insured patients undergoing hip arthroplasty in our study, PAC costs totaled $7.8 million (14% of total costs; n = 699 index PAC stays). Similarly, PAC costs were $12.7 million (14% of total costs; n = 897 index PAC stays) for 3403 patients undergoing knee arthroplasty. By holding the providers clinically and financially responsible for PACs, and by segmenting and quantifying the type of PACs generated during and after the procedure, the Prometheus model creates an opportunity for providers to focus on the reduction of PACs, including readmissions, making the data actionable and turn the waste related to PAC costs into potential savings.
Transfusions and blood loss in total hip and knee arthroplasty: a prospective observational study.
Carling, Malin S; Jeppsson, Anders; Eriksson, Bengt I; Brisby, Helena
2015-03-28
There is a high prevalence of blood product transfusions in orthopedic surgery. The reported prevalence of red blood cell transfusions in unselected patients undergoing hip or knee replacement varies between 21% and 70%. We determined current blood loss and transfusion prevalence in total hip and knee arthroplasty when tranexamic acid was used as a routine prophylaxis, and further investigated potential predictors for excessive blood loss and transfusion requirement. In total, 193 consecutive patients undergoing unilateral hip (n = 114) or knee arthroplasty (n = 79) were included in a prospective observational study. Estimated perioperative blood loss was calculated and transfusions of allogeneic blood products registered and related to patient characteristics and perioperative variables. Overall transfusion rate was 16% (18% in hip patients and 11% in knee patients, p = 0.19). Median estimated blood loss was significantly higher in hip patients (984 vs 789 mL, p < 0.001). Preoperative hemoglobin concentration was the only independent predictor of red blood cell transfusion in hip patients while low hemoglobin concentration, body mass index, and operation time were independent predictors for red blood cell transfusion in knee patients. The prevalence of red blood cell transfusion was lower than previously reported in unselected total hip or knee arthroplasty patients. Routine use of tranexamic acid may have contributed. Low preoperative hemoglobin levels, low body mass index, and long operation increase the risk for red blood cell transfusion.
Clinical and biomechanical assessment of patella resurfacing in total knee arthroplasty.
Berti, Lisa; Benedetti, Maria Grazia; Ensini, Andrea; Catani, Fabio; Giannini, Sandro
2006-07-01
Currently there is a limited understanding of the factors influencing range of motion by comparing patellar resurfacing vs non-resurfacing in total knee arthroplasty during activities of daily living. A recent meta-analysis of patellar replacement confirms better outcome with patella resurfacing; however, the result can be influenced by many other factors, such as: component design, surgeon experience, and technical aspects of the surgery. This study compares the biomechanics of the knee in patients after total knee arthroplasty with and without patellar resurfacing during stair climbing. Forty-seven patients with total knee arthroplasty were assessed at the mean follow-up of 24 months. In all of them a posterior stabilised fixed bearing prosthesis (Optetrak PS, Exactech) was implanted. Twenty-six patients were treated without patellar resurfacing and 21 with patellar resurfacing. Clinical evaluations were performed using the International Knee Society and the Hospital for Special Surgery scores. Ten patients with patellar resurfacing and 10 patients without patellar resurfacing were also studied with motion analysis during stair climbing; 10 healthy subjects were studied for statistical comparison. Clinical passive knee flexion, International Knee Society Function and Hospital for Special Surgery scores were significantly higher in the patellar resurfacing group. During stair climbing, active knee joint range of motion during the stance phase was greater in patients with patellar resurfacing. The maximum adduction moment was significantly higher in the group without patellar resurfacing. Patients with patellar resurfacing demonstrated better clinical scores, and kinematic and kinetic data while ascending stairs.
Patient's decision making in selecting a hospital for elective orthopaedic surgery.
Moser, Albine; Korstjens, Irene; van der Weijden, Trudy; Tange, Huibert
2010-12-01
The admission to a hospital for elective surgery, like arthroplasty, can be planned ahead. The elective nature of arthroplasty and the increasing stimulus of the public to critically select a hospital raise the issue of how patients actually take such decisions. The aim of this paper is to describe the decision-making process of selecting a hospital as experienced by people who underwent elective joint arthroplasty and to understand what factors influenced the decision-making process. Qualitative descriptive study with 18 participants who had a hip or knee replacement within the last 5 years. Data were gathered from eight individual interviews and four focus group interviews and analysed by content analysis. Three categories that influenced the selection of a hospital were revealed: information sources, criteria in decision making and decision-making styles within the GP- patient relationship. Various contextual aspects influenced the decision-making process. Most participants gave higher priority to the selection of a medical specialist than to the selection of a hospital. Selecting a hospital for arthroplasty is extremely complex. The decision-making process is a highly individualized process because patients have to consider and assimilate a diversity of aspects, which are relevant to their specific situation. Our findings support the model of shared decision making, which indicates that general practitioners should be attuned to the distinct needs of each patient at various moments during the decision making, taking into account personal, medical and contextual factors. © 2010 Blackwell Publishing Ltd.
Berger, Richard A; Sanders, Sheila A; Thill, Elizabeth S; Sporer, Scott M; Della Valle, Craig
2009-06-01
Advancements in the surgical approach, anesthetic technique, and the initiation of rapid rehabilitation protocols have decreased the duration of hospitalization and subsequent length of recovery following elective total hip arthroplasty. We assessed the feasibility and safety of outpatient total hip arthroplasty in 150 consecutive patients. A comprehensive perioperative anesthesia and rehabilitation protocol including preoperative teaching, regional anesthesia, and preemptive oral analgesia and antiemetic therapy was implemented around a minimally invasive surgical technique. A rapid rehabilitation pathway was started immediately after surgery and patients had the option of being discharged to home the day of surgery if standard discharge criteria were met. All 150 patients were discharged to home the day of surgery, at which time 131 patients were able to walk without assistive devices. Thirty-eight patients required some additional intervention outside the pathway to resolve nausea, hypotension, or sedation prior to discharge. There were no readmissions for pain, nausea, or hypotension yet there was one readmission for fracture and nine emergency room evaluations in the three month perioperative period. This anesthetic and rehabilitation protocol allowed outpatient total hip arthroplasty to be routinely performed in these consecutive patients undergoing primary total hip arthroplasty. With current reimbursement approaches the modest savings to the hospital in length of stay may be outweighed by the additional costs of personnel, thereby making this outpatient system more expensive to implement. Level IV, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.
Kiskaddon, Eric M; Lee, Jessica H; Meeks, Brett D; Barnhill, Spencer W; Froehle, Andrew W; Krishnamurthy, Anil
2018-05-01
Attempts to control costs associated with total joint arthroplasty have included efforts to shorten hospital length of stay (LOS). Concerns related to patient outcomes and safety with decreased LOS persist. The purpose of this study was to investigate whether discharge on postoperative day (POD) 1 after joint replacement is associated with increased rates of 90-day return to the operating room, and 30-day readmissions and emergency department (ED) visits. After chart review, 447 patients admitted between January 2, 2013 and September 16, 2016 met inclusion criteria. All patients underwent one total joint arthroplasty. Patients were either discharged on POD 1 (subgroup 1) or POD 2 or 3 (subgroup 2). Statistical evaluation was performed using Wilcoxon-Mann-Whitney tests for continuous variables, and Fisher exact tests for categorical and frequency data. Statistical significance was established at P ≤ .05. Subgroup 1 had significantly fewer return trips to the operating room (P = .043) and significantly fewer 30-day readmissions (P = .033). ED visits were not significantly different between groups (P = .901). Early discharge after joint arthroplasty appears to be a viable practice and did not result in increased rates of reoperation within the 90-day global period, or rates of 30-day readmission and ED visits. Our results support the utilization of an early discharge protocol on POD 1, with no evidence that shorter LOS results in higher rates of short-term complications. Copyright © 2017 Elsevier Inc. All rights reserved.
Riddle, Daniel L.; Keefe, Francis J.; Nay, William T.; McKee, Daphne; Attarian, David E.; Jensen, Mark P.
2011-01-01
Objectives To (1) describe a behavioral intervention designed for patients with elevated pain catastrophizing who are scheduled for knee arthroplasty, and (2) use a quasi-experimental design to evaluate the potential efficacy of the intervention on pain severity, catastrophizing cognitions, and disability. Design Quasi-experimental non-equivalent control group design with a 2 month follow-up. Setting Two university-based Orthopedic Surgery departments. Participants Adults scheduled for knee replacement surgery who reported elevated levels of pain catastrophizing. Patients were recruited from two clinics and were assessed prior to surgery and 2 months following surgery. Intervention A group of 18 patients received a psychologist directed pain coping skills training intervention comprising 8 sessions and the other group, a historical cohort of 45 patients, received usual care. Main Outcome Measures WOMAC Pain and Disability scores as well as scores on the Pain Catastrophizing Scale. Results Two months following surgery, the patients who received pain coping skills training reported significantly greater reductions in pain severity and catastrophizing, and greater improvements in function as compared to the usual care cohort. Conclusion Pain catastrophizing is known to increase risk of poor outcome following knee arthroplasty. The findings provide preliminary evidence that the treatment may be highly efficacious for reducing pain, catastrophizing, and disability, in patients reporting elevated catastrophizing prior to knee arthroplasty. A randomized clinical trial is warranted to confirm these effects. PMID:21530943
Boss, J H; Shajrawi, I; Mendes, D G
1994-01-01
The morphological appearances of the interface between the bone and the components of arthroplasties depend on multiple factors. Present-day biomaterials being biocompatible when in bulk form, a host reaction consequent upon untoward effects of the implants as such is not expected. Thus, osseointegration, i.e., the direct apposition of bone to the surface of a foreign material at the light microscopical level, occurs, under favorable biomechanical circumstances, irrespective of the chemical composition of the implant. Osseointegration is a multifaceted phenomenon. First and foremost, it evolves when an initially rigid fixation of the component is surgically attained. Interfacial motions are associated with resorption of the bony bed, macrophagic activation and production of wear particles, the close bone-implant apposition is lost and the formation of an interfacial membrane (IM) ensues. The histological features of the IM coincide with the context of its formation and evolution. The quiescent IM is composed of a thin layer of fibrous tissue and its occurrence is compatible with the biofunctionality of the implant. The aggressive or lytic IM (LIM) develops when tissue-irritating, small, irregularly shaped and edgy breakdown products are deposited at the interface. The thick LIM consists of an inflamed fibrous tissue, scattered within which are myriad granulomas, and its surface facing the implant displays a synovial-like aspect. The mono- and polykaryonic macrophages, constituting the granulomatous response, ingest and abut on the wear particles. Amongst the intermediary substances of inflammation elaborated by the lymphocytes and macrophages of the LIM, factors which stimulate the osteoclasts play the pivotal role in as much as progressive bone resorption is associated with progressive growth of the IM and, hence, with incremental interfacial motion, interfacial deposition of wear particles and inflammatory-granulomatous response. The ensuing vicious circle culminates in aseptic loosening of the arthroplasty. The morphological features of the LIM, though characterized by a stereotypical reaction pattern, are, in their details, closely linked with the nature of the diverse components of the composite joint replacement. The histological appearances of the bone-implant interface of stable and loose arthroplasties, the tissular reactions to polymethylmethacrylate, polyethylene, polyacetal, metals and hydroxyapatite as well as the characteristics of cemented and cementless porous-coated, press-fit and hydroxyapatite-coated prostheses are described.
Rud, I M; Melnikova, E A; Rassulova, M A; Razumov, A N; Gorelikov, A E
2017-12-28
The present article is the analytical review of the literature pertaining to the problem of rehabilitation of the patients following the endoprosthetic replacement of joints of the lower extremities. The relevance of the problem of interest for medical rehabilitation is beyond any doubt. The traditional methods for the rehabilitation of the patients do not always lead to the desired results. The authors discuss in detail the need for and the contemporary approaches to the rehabilitation of the patients who had undergone reconstructive surgery and arthroplasty of the joints of the lower extremities. The pathogenetically-based three-stage algorithm for medical rehabilitation is proposed.
Brock, Timothy M; Sidaginamale, Raghavendra; Rushton, Steven; Nargol, Antoni V F; Bowsher, John G; Savisaar, Christina; Joyce, Tom J; Deehan, David J; Lord, James K; Langton, David J
2015-12-01
Taper wear at the head-neck junction is a possible cause of early failure in large head metal-on-metal (LH-MoM) hip replacements. We hypothesized that: (i) taper wear may be more pronounced in certain product designs; and (ii) an increased abductor moment arm may be protective. The tapers of 104 explanted LH-MoM hip replacements revised for adverse reaction to metal debris (ARMD) from a single manufacturer were analyzed for linear and volumetric wear using a co-ordinate measuring machine. The mated stem was a shorter 12/14, threaded trunnion (n=72) or a longer, smooth 11/13 trunnion (n=32). The abductor moment arm was calculated from pre-revision radiographs. Independent predictors of linear and volumetric wear included taper angle, stem type, and the horizontal moment arm. Tapers mated with the threaded 12/14 trunnion had significantly higher rates of volumetric wear (0.402 mm3/yr vs. 0.123 mm3/yr [t=-2.145, p=0.035]). There was a trend to larger abductor moment arms being protective (p=0.055). Design variation appears to play an important role in taper-trunnion junction failure. We recommend that surgeons bear these findings in mind when considering the use of a short, threaded trunnion with a cobalt-chromium head. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.
White, Nicholas A; Moreno, Daniel P; Brown, Philip J; Gayzik, F Scott; Hsu, Wesley; Powers, Alexander K; Stitzel, Joel D
2014-09-01
Whereas arthrodesis is the most common surgical intervention for the treatment of symptomatic cervical degenerative disc disease, arthroplasty has become increasingly more popular over the past decade. Although literature exists comparing the effects of anterior cervical discectomy and fusion and cervical total disc replacement (CTDR) on neck kinematics and loading, the vast majority of these studies apply only quasi-static, noninjurious loading conditions to a segment of the cervical spine. The objective of this study was to investigate the effects of arthrodesis and arthroplasty on biomechanical neck response during a simulated frontal automobile collision with air bag deployment. This study used a full-body, 50th percentile seated male finite element (FE) model to evaluate neck response during a dynamic impact event. The cervical spine was modified to simulate either an arthrodesis or arthroplasty procedure at C5-C6. Five simulations of a belted driver, subjected to a 13.3 m/s ΔV frontal impact with air bag deployment, were run in LS-DYNA with the Global Human Body Models Consortium full-body FE model. The first simulation used the original model, with no modifications to the neck, whereas the remaining four were modified to represent either interbody arthrodesis or arthroplasty of C5-C6. Cross-sectional forces and moments at the C5 and C6 cervical levels of the neck, along with interbody and facet forces between C5 and C6, were reported. Adjacent-level, cross-sectional neck loading was maintained in all simulations without exceeding any established injury thresholds. Interbody compression was greatest for the CTDRs, and interbody tension occurred only in the fused and nonmodified spines. Some interbody separation occurred between the superior and inferior components of the CTDRs during flexion-induced tension of the cervical spine, increasing the facet loads. This study evaluated the effects of C5-C6 cervical arthrodesis and arthroplasty on neck response during a simulated frontal automobile impact. Although cervical arthrodesis and arthroplasty at C5-C6 did not appear to significantly alter the adjacent-level, cross-sectional neck responses during a simulated frontal automobile impact, key differences were noted in the interbody and facet loading. Copyright © 2014 Elsevier Inc. All rights reserved.
Joint Stability in Total Knee Arthroplasty: What Is the Target for a Stable Knee?
Wright, Timothy M
2017-02-01
Instability remains a common cause of failure in total knee arthroplasty. Although approaches for surgical treatment of instability exist, the target for initial stability remains elusive, increasing the likelihood that failures will persist because adequate stability is not restored when performing the primary arthroplasty. Although the mechanisms that stabilize the knee joint-contact between the articular surfaces, ligamentous constraints, and muscle forces-are well-defined, their relative importance and the interplay among them throughout functions of daily living are poorly understood. The problem is exacerbated by the complex multiplanar motions that occur across the joint and the large variations in these motions across the population, suggesting that stability targets may need to be patient-specific.
Tan, H L; Lin, W T; Tang, T T
2012-10-01
Despite improvements in intraoperative antimicrobial procedures, in surgical techniques and in implant design for joint replacement, periprosthetic infection after arthroplasty is still one of the most challenging problems encountered by orthopedic surgeons. Systemic antibiotics are not sufficiently effective to eradicate such deep infections because of the impaired blood circulation and low antibiotic concentration at the implantation site. As a local drug delivery system, antibiotic-impregnated PMMA (polymethylmethacrylate) bone cements have been widely used for prophylaxis or treatment of deep infections after total joint replacement. However, the effectiveness of antibiotic-loaded PMMA in preventing infections after arthroplasty is still controversial. Furthermore, the outcomes of established deep infections treated with this technique are not consistent. The local use of antibiotics has led to the emergence of antibiotic-resistant bacterial strains and has adverse effects on the function of osteogenic cells. Recently, many efforts have been made to identify new antibacterial agents that can be loaded into PMMA. These antimicrobial agents should exhibit good antibacterial activity against antibiotic-resistant strains and should simultaneously enhance osteointegration between the PMMA and the bone tissue. PMMA loaded with chitosan or chitosan derivatives has been demonstrated to induce improved osteogenic activity and to exhibit antibacterial activity in a preclinical study.
Huang, Chun-Hsiung; Ho, Fang-Yuan; Ma, Hon-Ming; Yang, Chan-Tsung; Liau, Jiann-Jong; Kao, Hung-Chan; Young, Tai-Horng; Cheng, Cheng-Kung
2002-09-01
Osteolysis induced by ultrahigh molecular weight polyethylene wear debris has been recognized as the major cause of long-term failure in total joint arthroplasties. In a previous study, the prevalence of intraoperatively identified osteolysis during primary revision surgery was much higher in mobile bearing knee replacements (47%) than in fixed bearing knee replacements (13%). We postulated that mobile bearing knee implants tend to produce smaller sized particles. In our current study, we compared the particle size and morphology of polyethylene wear debris between failed mobile bearing and fixed bearing knees. Tissue specimens from interfacial and lytic regions were extracted during revision surgery of 10 mobile bearing knees (all of the low contact stress (LCS) design) and 17 fixed bearing knees (10 of the porous-coated anatomic (PCA) and 7 of the Miller/Galante design). Polyethylene particles were isolated from the tissue specimens and examined using both scanning electron microscopy and light-scattering analyses. The LCS mobile bearing knees produced smaller particulate debris (mean equivalent spherical diameter: 0.58 microm in LCS, 1.17 microm in PCA and 5.23 microm in M/G) and more granular debris (mean value: 93% in LCS, 77% in PCA and 15% in M/G).
Second-site prosthetic joint infection in patients with multiple prosthetic joints.
Clesham, Kevin; Hughes, Andrew J; O' hEireamhoin, Sven; Fleming, Catherine; Murphy, Colin G
2018-04-10
Prosthetic joint infections (PJIs) are among the most serious complications in arthroplasty. A second-site PJI in patients with multiple prosthetic joints increases morbidity, with many requiring further revision procedures. We aimed to establish why some patients with multiple joints develop second-site infections. Our institution's arthroplasty database was reviewed from 2004 to 2017. All PJIs were identified, and all patients with more than one prosthetic joint in situ were included. We recorded risk factors, causative organisms, number of procedures and length of stay. Forty-four patients meeting the criteria were identified. Four patients (9.1%) developed second-site infection. Eight patients (18.2%) developed re-infection of the primary PJI. Positive MRSA carrier status and PJI of a total knee replacement were associated with an increased risk of a second episode of infection. Patients who developed further infection had more frequent admission and longer lengths of stay than isolated PJIs. Higher morbidity and use of hospital resources are associated with this cohort of patients. PJIs in total knee replacements and positive MRSA status are associated with higher rates of second infection. Identifying this vulnerable cohort of patients at an early stage is critical to ensure measures are taken to reduce the risks of further infection.
Lewis, Peter L; Gamboa, Ai E; Campbell, David G; Lorimer, Michelle
2017-10-01
Although knee replacements have specifically designed patella prostheses that correspond to the geometry of their femoral components, a patella prosthesis that is unmatched to the femoral component may occasionally be inserted. In revision total knee arthroplasty (TKA), an originally resurfaced patella may be left, but the femoral component revised to one that does not match the patella. Few studies have compared the outcome of matched and unmatched patella components in TKA. This study compared the primary or revision TKA outcome of procedures where patella components matched to their femoral counterparts were inserted, with procedures using patella and femoral components that were unmatched. Data on all primary and revision TKA procedures without a patella component or a matched or an unmatched patella component were obtained from the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR). Revision surgery was the outcome measure. Cumulative percent revised (CPR) were calculated and Hazard ratios with p values were used to test statistical significance. In primary TKA, there were higher rates of revision where unmatched patella components were used, regardless of implant design. There was no difference in the second revision rates of unmatched versus matched patella component groups. This was evident where delayed resurfacing was carried out, and where the patella prosthesis was left alone but the femoral component was changed. All primary TKA procedures require a patella component corresponding to the femoral component if the patella is resurfaced. Conversely, revision knee arthroplasties are not affected by the use of dissimilar patella and femoral components. Copyright © 2017 Elsevier B.V. All rights reserved.
Lameijer, Joost R C; Verboom, Frederik; Grefkens, Joost; Jansen, Joris
2016-10-01
Local infiltration analgesia (LIA) during total knee arthroplasty has been shown to give statistically significant reduction in post-operative pain. The effects of using high volumes of ropivacaine combined with adrenaline as LIA on cardiovascular parameters in knee replacement have not been described before. The objective of this study was to investigate the cardiovascular safety of ropivacaine as part of high volume local infiltration analgesia (LIA) in total knee replacement surgery. This is a retrospective observational comparative cohort study conducted in two independent cohorts, one treated without and one treated with a local infiltration analgesia protocol, containing a total of 744 patients with a mean age of 68years (42 to 89) and 68years (21 to 88) respectively with a follow-up of 12months. No statistical difference in bradycardia during surgery, post-operative cardiovascular complications, and mortality was found after use of LIA. A statistically significant lower incidence of hypotension was found in the LIA group (P<0.01). This result has to be interpreted with care, due to the use of adrenaline in the LIA mixture, which could mask possible hypotension. No statistical difference was found in the occurrence of hypertension or tachycardia, despite the addition of adrenaline to the LIA mixture. No difference in mortality was found between the two groups (P=0.11). These results show safe use of high volume ropivacaine with adrenaline as local infiltration analgesia during total knee replacement surgery. Copyright © 2016 Elsevier B.V. All rights reserved.
Dmitriev, Anton E; Gill, Norman W; Kuklo, Timothy R; Rosner, Michael K
2008-01-01
With lumbar arthroplasty gaining popularity, limited data are available highlighting changes in adjacent-level mechanics after multilevel procedures. Compare operative- and adjacent-segment range of motion (ROM) and intradiscal pressures (IDPs) after two-level arthroplasty versus circumferential arthrodesis. Cadaveric biomechanical study. Ten human cadaveric lumbar spines were used in this investigation. Biomechanical testing was performed according to a hybrid testing protocol using an unconstrained spine simulator under axial rotation (AR), flexion extension (FE), and lateral-bending (LB) loading. Specimens were tested in the following order: 1) Intact, 2) L3-L5 total disc replacement (TDR), 3) L3-L5 anterior interbody cages+pedicle screws. IDP was recorded at proximal and distal adjacent levels and normalized to controls (%intact). Full ROM was monitored at the operative and adjacent levels and reported in degrees. Kinematics assessment revealed L3-L5 ROM reduction after both reconstructions versus intact controls (p < .05). However, global quality of segmental motion distributed over L2-S1 was preserved in the arthroplasty group but was significantly altered after circumferential fixation. Furthermore, adjacent-level ROM was increased for the arthrodesis group under LB at both segments and during AR at L2-L3 relative to controls (p < .05). FE did not reveal any intergroup statistical differences. Nonetheless, after arthrodesis IDPs were increased proximally under all three loading modalities, whereas distally a significant IDP rise was noted during AR and LB (p < .05). No statistical differences in either biomechanical parameter were recorded at the adjacent levels between intact control and TDR groups. Our results indicate no significant adjacent-level biomechanical changes between arthroplasty and control groups. In contrast, significant alterations in ROM and IDP were recorded both proximally (ROM=LB & AR; IDP=AR, FE, LB) and distally (ROM=LB; IDP=AR & LB) after circumferential arthrodesis. Therefore, two-level lumbar arthroplasty maintains a more favorable biomechanical environment at the adjacent segments compared with the conventional transpedicular fixation technique. This, in turn, may have a positive effect on the rate of the transition syndrome postoperatively.
Buhagiar, Mark A; Naylor, Justine M; Harris, Ian A; Xuan, Wei; Kohler, Friedbert; Wright, Rachael J; Fortunato, Renee
2013-12-17
Formal rehabilitation programs are often assumed to be required after total knee arthroplasty to optimize patient recovery. Inpatient rehabilitation is a costly rehabilitation option after total knee arthroplasty and, in Australia, is utilized most frequently for privately insured patients. With the exception of comparisons with domiciliary services, no randomized trial has compared inpatient rehabilitation to any outpatient based program. The Hospital Inpatient versus HOme (HIHO) study primarily aims to determine whether 10 days of post-acute inpatient rehabilitation followed by a hybrid home program provides superior recovery of functional mobility on the 6-minute walk test (6MWT) compared to a hybrid home program alone following total knee arthroplasty. Secondarily, the trial aims to determine whether inpatient rehabilitation yields superior recovery in patient-reported function. This is a two-arm parallel randomized controlled trial (RCT), with a third, non-randomized, observational group. One hundred and forty eligible, consenting participants who have undergone a primary total knee arthroplasty at a high-volume joint replacement center will be randomly allocated when cleared for discharge from acute care to either 10 days of inpatient rehabilitation followed by usual care (a 6-week hybrid home program) or to usual care. Seventy participants in each group (140 in total) will provide 80% power at a significance level of 5% to detect an increase in walking capacity from 400 m to 460 m between the Home and Inpatient groups, respectively, in the 6MWT at 6 months post-surgery, assuming a SD of 120 m and a drop-out rate of <10%.The outcome assessor will assess participants at 10, 26 and 52 weeks post-operatively, and will remain blind to group allocation for the duration of the study, as will the statistician. Participant preference for rehabilitation mode stated prior to randomization will be accounted for in the analysis together with any baseline differences in potentially confounding characteristics as required. The HIHO Trial will be the first RCT to investigate the efficacy of inpatient rehabilitation compared to any outpatient alternative following total knee arthroplasty. U.S. National Institutes of Health Clinical Trials Registry (http://clinicaltrials.gov) ref: NCT01583153.
Elshoury, Amro; Khedr, Maha; Abousayed, Mostafa M; Mehdi, Syed
2015-09-01
Heparin-induced thrombocytopenia syndrome is an acquired potentially life-threatening prothrombotic disorder caused by antibodies that recognize complexes of platelet factor 4 bound to heparin or heparin-like molecules. It typically occurs after exposure to unfractionated heparin, to a lesser extent after exposure to low-molecular-weight heparins, and rarely after exposure to fondaparinux. Herein, we report the case of a 48-year-old woman who developed severe thrombocytopenia, bilateral pulmonary embolism, and bilateral adrenal hemorrhages after total knee arthroplasty without evidence of heparin exposure. Antibodies to the heparin-platelet factor 4 complex and serotonin-release assay were positive. Spontaneous heparin-induced thrombocytopenia syndrome should be considered in patients with unexplained thrombocytopenia after knee replacement surgery even without heparin exposure, and a high index of suspicion for adrenal hemorrhage is needed in patients with fever, abdominal pain, and shock.
Factors affecting wound ooze in total knee replacement
Butt, U; Ahmad, R; Aspros, D; Bannister, GC
2010-01-01
INTRODUCTION Wound ooze is common following total knee arthroplasty (TKA) and persistent wound infection is a risk factor for infection, and increased length and cost of hospitalisation. PATIENTS AND METHODS We undertook a prospective study to assess the effect of tourniquet time, peri-articular local anaesthesia and surgical approach on wound oozing after TKA. RESULTS The medial parapatellar approach was used in 59 patients (77%) and subvastus in 18 patients (23%). Peri-articular local anaesthesia (0.25% Bupivacaine with 1:1,000,000 adrenalin) was used in 34 patients (44%). The mean tourniquet time was 83 min (range, 38–125 min). We found a significant association between cessation of oozing and peri-articular local anaesthesia (P = 0.003), length of the tourniquet time (P = 0.03) and the subvastus approach (P = 0.01). CONCLUSIONS Peri-articular local anaesthesia, the subvastus approach and shorter tourniquet time were all associated with less wound oozing after total knee arthroplasty. PMID:20836920
Crumley Aybar, Bonnie L; Gillespie, Michael J; Gipson, Sean F; Mullaney, Caitlin E; Tommasino-Storz, Melissa
2016-12-01
A systematic review of the literature was completed by the Evidence-Based Practice Group for the Patient population, Intervention/Issue, Comparison Intervention, Outcomes, Timing (PICOT) question: "Does the use of a peripheral nerve block increase the risk for falls and difficulty ambulation in patients after lower extremity surgery through postoperative day 2?" A search of multiple databases using specified key terms resulted in 258 articles for total knee arthroplasty or total hip arthroplasty. These were reduced to 13 with exclusion criteria and became primary evidence. Numbers Needed to Harm and Numbers Needed to Treat (NNT) were calculated. Numbers Needed to Harm supported the PICOT question. Further research of postoperative falls and nursing interventions to reduce or prevent falls is suggested before creation of a Clinical Practice Guideline. Copyright © 2016 American Society of PeriAnesthesia Nurses. Published by Elsevier Inc. All rights reserved.
Regional or general anesthesia for fast-track hip and knee replacement - what is the evidence?
Kehlet, Henrik; Aasvang, Eske Kvanner
2015-01-01
Regional anesthesia for knee and hip arthroplasty may have favorable outcome effects compared with general anesthesia by effectively blocking afferent input, providing initial postoperative analgesia, reducing endocrine metabolic responses, and providing sympathetic blockade with reduced bleeding and less risk of thromboembolic complications but with undesirable effects on lower limb motor and urinary bladder function. Old randomized studies supported the use of regional anesthesia with fewer postoperative pulmonary and thromboembolic complications, and this has been supported by recent large non-randomized epidemiological database cohort studies. In contrast, the data from newer randomized trials are conflicting, and recent studies using modern general anesthetic techniques may potentially support the use of general versus spinal anesthesia. In summary, the lack of properly designed large randomized controlled trials comparing modern general anesthesia and spinal anesthesia for knee and hip arthroplasty prevents final recommendations and calls for prospective detailed studies in this clinically important field. PMID:26918127
Young, Simon W; Clarke, Henry D; Graves, Stephen E; Liu, Yen-Liang; de Steiger, Richard N
2015-05-01
Total knee arthroplasty (TKA) systems permit a degree of femoro-tibial component size mismatch. The effect of mismatched components on revision rates has not been evaluated in a large study. We reviewed 21,906 fixed-bearing PFC Sigma primary TKAs using the Australian Orthopaedic Association National Joint Replacement Registry, dividing patients into three groups: no femoro-tibial size mismatch, tibial component size > femoral component size, and femoral component > tibial component. Revision rates were higher when the femoral size was greater than the tibia, compared to both equal size (HR = 1.20 (1.00, 1.45), P = 0.047) and to tibial size greater than femoral (HR = 1.60 (1.08, 2.37), P = 0.019). Potential mechanisms to explain these findings include edge loading of polyethylene and increased tibial component stresses. Copyright © 2014 Elsevier Inc. All rights reserved.
Biomechanical behavior of a cemented ceramic knee replacement under worst case scenarios
NASA Astrophysics Data System (ADS)
Kluess, D.; Mittelmeier, W.; Bader, R.
2009-12-01
In connection with technological advances in the manufacturing of medical ceramics, a newly developed ceramic femoral component was introduced in total knee arthroplasty (TKA). The motivation to consider ceramics in TKA is based on the allergological and tribological benefits as proven in total hip arthroplasty. Owing to the brittleness and reduced fracture toughness of ceramic materials, the biomechanical performance has to be examined intensely. Apart from standard testing, we calculated the implant performance under different worst case scenarios including malposition, bone defects and stumbling. A finite-element-model was developed to calculate the implant performance in situ. The worst case conditions revealed principal stresses 12.6 times higher during stumbling than during normal gait. Nevertheless, none of the calculated principal stress amounts were above the critical strength of the ceramic material used. The analysis of malposition showed the necessity of exact alignment of the implant components.
Yoo, Jun Il; Ha, Yong Chan; Lim, Jae Young; Kang, Hyun; Yoon, Byung Ho; Kim, Hyunho
2017-05-01
The purpose of this study was to compare the outcomes focusing on the functional outcome and clinical results of replacement arthroplasty (AP) vs. internal fixation (IF) for the treatment of unstable intertrochanteric femoral fracture in elderly. Systematic review and meta-analysis were performed on 10 available clinical studies (2 randomized controlled trials and 8 comparative studies). Subgroup analysis was performed by type of methodological quality. Partial weight bearing time in AP group was earlier than that in IF group (SMD = -0.86; 95% CI = -0.42, 1.29; P = 0.050). The overall outcomes such as mortality, reoperation rate, and complication showed no significant diffrence between the 2 groups (AP vs. IF). Therefore, this systematic review demonstrates that AP provides superior functional outcomes especially earlier mobilization, as compared to IF in elderly patients with an unstable intertrochanteric femoral fracture. © 2017 The Korean Academy of Medical Sciences.
Outcomes of Total Knee Arthroplasty in Patients With Poliomyelitis.
Gan, Zhi-Wei Jonathan; Pang, Hee Nee
2016-11-01
We report our experience with outcomes of poliomyelitis in the Asian population. Sixteen total knee replacements in 14 patients with polio-affected knees were followed up for at least 18 months. Follow-up assessment included scoring with the American Knee Society Score (AKSS), Oxford knee score, and Short Form 36 Health Survey scores. The mean AKSS improved from 25.59 preoperatively to 82.94 at 24 months, with greater improvement in the knee score. The mean Oxford knee score improved from 40.82 preoperatively to 20.53 at 24 months. The mean AKSS pain score rose from 2.35 to 47.66 at 24 months. The Short Form 36 Health Survey physical functioning and bodily pain scores improved for all patients. Primary total knee arthroplasty of poliomyelitis-affected limbs shows good outcomes, improving quality of life, and decreasing pain. Copyright © 2016 Elsevier Inc. All rights reserved.
Biomechanical behavior of a cemented ceramic knee replacement under worst case scenarios
NASA Astrophysics Data System (ADS)
Kluess, D.; Mittelmeier, W.; Bader, R.
2010-03-01
In connection with technological advances in the manufacturing of medical ceramics, a newly developed ceramic femoral component was introduced in total knee arthroplasty (TKA). The motivation to consider ceramics in TKA is based on the allergological and tribological benefits as proven in total hip arthroplasty. Owing to the brittleness and reduced fracture toughness of ceramic materials, the biomechanical performance has to be examined intensely. Apart from standard testing, we calculated the implant performance under different worst case scenarios including malposition, bone defects and stumbling. A finite-element-model was developed to calculate the implant performance in situ. The worst case conditions revealed principal stresses 12.6 times higher during stumbling than during normal gait. Nevertheless, none of the calculated principal stress amounts were above the critical strength of the ceramic material used. The analysis of malposition showed the necessity of exact alignment of the implant components.
The Perioperative Surgical Home: Improving the Value and Quality of Care in Total Joint Replacement.
Chimento, George F; Thomas, Leslie C
2017-09-01
The perioperative surgical home (PSH) is a patient-centered, physician-led, multidisciplinary care pathway developed to deliver value-based care based on shared decision-making. Physician and hospital reimbursement will be tied to providing quality care at lower cost, and the PSH model has been used in providing care to patients undergoing lower extremity arthroplasty. The purpose of this review is to discuss the rationale, definition, development, current state, and future direction of the PSH. The PSH model guides the patient throughout the pre and perioperative process and into the postoperative phase. It has been shown in multiple studies to decrease length of stay, improve functional outcomes, allow more home discharges, and lower costs. There is no increase in complications or readmission rates. The PSH pathway is a safe and effective method of providing value-based care to patients undergoing hip and knee arthroplasty.
Factors affecting wound ooze in total knee replacement.
Butt, U; Ahmad, R; Aspros, D; Bannister, G C
2011-01-01
Wound ooze is common following total knee arthroplasty (TKA) and persistent wound infection is a risk factor for infection, and increased length and cost of hospitalisation. We undertook a prospective study to assess the effect of tourniquet time, peri-articular local anaesthesia and surgical approach on wound oozing after TKA. The medial parapatellar approach was used in 59 patients (77%) and subvastus in 18 patients (23%). Peri-articular local anaesthesia (0.25% Bupivacaine with 1:1,000,000 adrenalin) was used in 34 patients (44%). The mean tourniquet time was 83 min (range, 38-125 min). We found a significant association between cessation of oozing and peri-articular local anaesthesia (P = 0.003), length of the tourniquet time (P = 0.03) and the subvastus approach (P = 0.01). Peri-articular local anaesthesia, the subvastus approach and shorter tourniquet time were all associated with less wound oozing after total knee arthroplasty.
Inpatient mortality after elective primary total hip and knee joint arthroplasty in Botswana.
Lisenda, Laughter; Mokete, Lipalo; Mkubwa, Joseph; Lukhele, Mkhululi
2016-12-01
Total hip and knee joint arthroplasty (TJA) rank among the most successful orthopaedic operations. Several developing countries in Africa have started to perform these procedures that are routine in developed countries. The aims of this study were to measure the incidence and assess the determinants of in-hospital mortality after elective primary TJA in our unit and compare it with published data. This was a retrospective study of the first consecutive cohort of patients who underwent elective primary TJA in Princess Marina Hospital, Botswana between March 2009 and October 2015 (6.5 years). 346 elective joint replacements were performed comprising 153 total hip arthroplasties (THA) and 193 total knee arthroplasties (TKA); 36 % of the THA were in female patients and 82 % of TKA were in females. The mean age was 64.5 years (range 26-86). Three patients died giving an inpatient mortality rate of 0.86 %. These three mortalities represent 1.55 % (three out of 193) of all the TKA. There were no deaths after THA. The cause of mortality in two patients was an adverse cardiac event while the third mortality was due to pulmonary embolism. The inpatient mortality rate of 0.86 % following TJA is higher than the reported rates in the developed countries but comparable with data from other developing countries. The inpatient mortality rate following TKA was higher than that following THA and cardiovascular events proved to be the main cause of death. We recommend formal cardiology assessment and close peri-operative monitoring of all patients with a history of cardiovascular disease undergoing TJA.
Jawed, Akram; Kumar, Vijay; Malhotra, R; Yadav, C S; Bhan, S
2012-06-01
Since the introduction of mobile bearing total knee designs nearly 30 years back, many studies have been done to evaluate its long-term result. Comparison with fixed bearing designs has been done in the past, but the studies were confounded by variables such as disease, surgeon, bone quality, pain tolerance, etc. We attempt to eliminate these variables in this study. A total of 50 patients who had bilateral arthritis of the knee with similar deformity and pre-operative range of motion on both sides agreed to have one knee replaced with mobile bearing total knee design (PFC-RP) and the other with a fixed bearing design (PFC Sigma) were prospectively evaluated. Comparative analysis of both the designs was done at a mean follow-up of 40 months, minimizing patient, surgeon and observer related bias. Clinical and radiographic outcome, survival and complication rates were compared. At a mean follow-up of 40 months (range 36-47 months), no benefit of mobile bearing (PFC-RP) over fixed bearing design (PFC Sigma) could be demonstrated with respect to Knee Society scores, pain scores, range of flexion, subject preference or patello-femoral complication rates. Radiographs showed no difference in prosthetic alignment. No patient required a revision surgery till last follow-up. Our study demonstrated no advantage of the mobile-bearing arthroplasty over fixed bearing arthroplasty with regard to clinical results at short-term follow-up. However, longer follow-up is necessary to confirm whether these results are sustained.
Impact of chronic kidney disease stage on lower-extremity arthroplasty.
Deegan, Brian F; Richard, Raveesh D; Bowen, Thomas R; Perkins, Robert M; Graham, Jove H; Foltzer, Michael A
2014-07-01
End-stage renal disease and dialysis is commonly associated with poor outcomes after joint replacement surgery. The goal of this study was to evaluate postoperative complications in patients with less advanced chronic kidney disease undergoing total hip arthroplasty (THA) or total knee arthroplasty (TKA). Patients who underwent THA or TKA between 2004 and 2011 with stage 1, 2, or 3 chronic kidney disease were retrospectively reviewed via an electronic medical record. The authors compared 377 patients who had stage 1 to 2 chronic kidney disease with 402 patients who had stage 3 chronic kidney disease. No significant differences in 90-day readmission or revision rates were found between the stage 1 to 2 and stage 3 patient groups. For patients with stage 3 chronic kidney disease, the overall mortality rate was greater than that in patients with stage 1 to 2 chronic kidney disease. However, when adjusted for comorbid disease, no significant increases were seen in joint infection, readmission, or early revision between patients with stage 1 to 2 chronic kidney disease vs patients with stage 3 chronic kidney disease. The overall incidence of infection was high (3.5%) but far less than reported for patients with end-stage renal disease, dialysis, and kidney transplant. In conclusion, patients with stage 1, 2, or 3 chronic kidney disease may have a higher than expected rate of prosthetic joint infection (3.5%) after total joint arthroplasty. Patients with stage 3 chronic kidney disease are at higher risk for postoperative mortality compared with those with lesser stages of kidney disease. Copyright 2014, SLACK Incorporated.
Rampazo-Lacativa, Mariana Kátia; Santos, Ariene Angelini dos; Coimbra, Arlete Maria Valente; D'Elboux, Maria José
2015-01-01
Quality-of-life results have increasingly been evaluated among patients undergoing joint replacements. The objective of this study was to compare two assessment instruments for health-related quality of life (one generic and the other specific), among elderly patients undergoing total hip arthroplasty. Cross-sectional descriptive study in a reference hospital in the region of Campinas. The subjects were 88 elderly outpatients aged 60 years or over who underwent primary total hip arthroplasty. Two instruments for assessing health-related quality of life were applied: the generic Medical Study 36-item Short-Form Health Survey (SF-36) and the specific Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC). Cronbach's alpha and the ceiling and floor effects of the instruments were evaluated. The scores from both instruments showed that issues of a physical nature affected these elderly people's quality of life most. The pain and stiffness dimensions of WOMAC showed ceiling effects and only the functional capacity and pain dimensions of the SF-36 did not show the ceiling effect. The SF-36 presented floor effects in the dimensions of physical and emotional aspects. Cronbach's alpha was considered satisfactory in both instruments (α > 0.70). The floor and ceiling effects that were observed suggest that these instruments may present some limitations in detecting changes to the majority of the SF-36 dimensions, except for functional capacity and pain, and to the pain and stiffness dimensions of WOMAC, when applied to elderly people with total hip arthroplasty.
[Hip resurfacing arthroplasty].
Witzleb, W-C; Knecht, A; Beichler, T; Köhler, T; Günther, K-P
2004-11-01
In comparison to stemmed total hip replacements, hip resurfacing offers advantages especially in joint stability and amount of femoral bone resection. After the poor results achieved with this concept that were mainly caused by failure of the materials used, reintroduction of the metal-on-metal bearing initiated a renaissance. This bearing, the cementless cup, and the improved surgical technique led to better short- to medium-term results. Revision and complication rates are now comparable to conventional total hip replacements. The functional capacity of the method is higher. Because long-term results are not available, however, questions remain, for instance, the consequences of the higher metal ion serum concentrations or the impossibility of changing the inlay when femoral revision becomes necessary.
The "caviar" madreporic knee prosthesis.
Kenesi, C
1979-01-01
The madreporic ("caviar") prosthesis is a hinged knee prosthesis that can be inserted without the use of cement. The surfaces of the intramedullary stems are constructed with contiguous spheres one mm in diameter. These spaces are filled by bone trabeculae and haversian bone, providing permanent biologic fixation. Experimental madreporic knee arthroplasties in dogs show that bone probes these surfaces and produces solid attachments. Histologically, the trabeculae remain separated from the metal by a fine layer of fibrous tissue. The method of insertion of the prosthesis is simple. Preparing the epiphyses before any bone resection avoids the possibility of rotational positioning errors. The form of the intramedullary stems offers good positioning in the frontal plane. The analysis of an initial series of 15 cases shows results that are far from outstanding. The 2 deaths, the 2 cases of sepsis, and the recuperation of only mediocre motion can be explained, at least in part, by the advanced age of the patients and the poor bone quality of the rheumatoid patients. Nevertheless, this type of prosthesis has 2 important advantages. It avoids the complications from the use of acrylic cement and allows for a revision operation for cases of failed surface replacement designs. Obviously further experimentation with noncemented designs will continue and definitive studies will be reported later.
Infection after primary hip arthroplasty
2011-01-01
Background and purpose The aim of the present study was to assess incidence of and risk factors for infection after hip arthroplasty in data from 3 national health registries. We investigated differences in risk patterns between surgical site infection (SSI) and revision due to infection after primary total hip arthroplasty (THA) and hemiarthroplasty (HA). Materials and methods This observational study was based on prospective data from 2005–2009 on primary THAs and HAs from the Norwegian Arthroplasty Register (NAR), the Norwegian Hip Fracture Register (NHFR), and the Norwegian Surveillance System for Healthcare–Associated Infections (NOIS). The Norwegian Patient Register (NPR) was used for evaluation of case reporting. Cox regression analyses were performed with revision due to infection as endpoint for data from the NAR and the NHFR, and with SSI as the endpoint for data from the NOIS. Results The 1–year incidence of SSI in the NOIS was 3.0% after THA (167/5,540) and 7.3% after HA (103/1,416). The 1–year incidence of revision due to infection was 0.7% for THAs in the NAR (182/24,512) and 1.5% for HAs in the NHFR (128/8,262). Risk factors for SSI after THA were advanced age, ASA class higher than 2, and short duration of surgery. For THA, the risk factors for revision due to infection were male sex, advanced age, ASA class higher than 1, emergency surgery, uncemented fixation, and a National Nosocomial Infection Surveillance (NNIS) risk index of 2 or more. For HAs inserted after fracture, age less than 60 and short duration of surgery were risk factors of revision due to infection. Interpretation The incidences of SSI and revision due to infection after primary hip replacements in Norway are similar to those in other countries. There may be differences in risk pattern between SSI and revision due to infection after arthroplasty. The risk patterns for revision due to infection appear to be different for HA and THA. PMID:22066562
Heo, Dong Hwa; Lee, Dong Chan; Oh, Jong Yang; Park, Choon Keun
2017-02-01
OBJECTIVE Bony overgrowth and spontaneous fusion are complications of cervical arthroplasty. In contrast, bone loss or bone remodeling of vertebral bodies at the operation segment after cervical arthroplasty has also been observed. The purpose of this study is to investigate a potential complication-bone loss of the anterior portion of the vertebral bodies at the surgically treated segment after cervical total disc replacement (TDR)-and discuss the clinical significance. METHODS All enrolled patients underwent follow-up for more than 24 months after cervical arthroplasty using the Baguera C disc. Clinical evaluations included recording demographic data and measuring the visual analog scale and Neck Disability Index scores. Radiographic evaluations included measurements of the functional spinal unit's range of motion and changes such as bone loss and bone remodeling. The grading of the bone loss of the operative segment was classified as follows: Grade 1, disappearance of the anterior osteophyte or small minor bone loss; Grade 2, bone loss of the anterior portion of the vertebral bodies at the operation segment without exposure of the artificial disc; or Grade 3, significant bone loss with exposure of the anterior portion of the artificial disc. RESULTS Forty-eight patients were enrolled in this study. Among them, bone loss developed in 29 patients (Grade 1 in 15 patients, Grade 2 in 6 patients, and Grade 3 in 8 patients). Grade 3 bone loss was significantly associated with postoperative neck pain (p < 0.05). Bone loss was related to the motion preservation effect of the operative segment after cervical arthroplasty in contrast to heterotopic ossification. CONCLUSIONS Bone loss may be a potential complication of cervical TDR and affect early postoperative neck pain. However, it did not affect mid- to long-term clinical outcomes or prosthetic failure at the last follow-up. Also, this phenomenon may result in the motion preservation effect in the operative segment after cervical TDR.
Design limitations of Bryan disc arthroplasty.
Fong, Shee Yan; DuPlessis, Stephan J; Casha, Steven; Hurlbert, R John
2006-01-01
Disc arthroplasty is gaining momentum as a surgical procedure in the treatment of spinal degenerative disease. Results must be carefully scrutinized to recognize benefits as well as limitations. The aim of this study was to investigate factors associated with segmental kyphosis after Bryan disc replacement. Prospective study of a consecutively enrolled cohort of 10 patients treated in a single center using the Bryan cervical disc prosthesis for single-level segmental reconstruction in the surgical treatment of cervical radiculopathy and/or myelopathy. Radiographic and quality of life outcome measures. Static and dynamic lateral radiographs were digitally analyzed in patients undergoing Bryan disc arthroplasty throughout a minimum 3-month follow-up period. Observations were compared with preoperative studies looking for predictive factors of postoperative spinal alignment. Postoperative end plate angles through the Bryan disc in the neutral position were kyphotic in 9 of 10 patients. Compared with preoperative end plate angulation there was a mean change of -7 degrees (towards kyphosis) in postoperative end plate alignment (p=.007, 95% confidence interval [CI] -6 degrees to -13 degrees). This correlated significantly with postoperative reduction in posterior vertebral body height of the caudal segment (p=.011, r2=.575) and postoperative functional spine unit (FSU) kyphosis (p=.032, r2=.46). Despite intraoperative distraction, postoperative FSU height was significantly reduced, on average by 1.7 mm (p=.040, 95% CI 0.5-2.8 mm). Asymmetrical end plate preparation occurs because of suboptimal coordinates to which the milling jig is referenced. Although segmental motion is preserved, Bryan disc arthroplasty demonstrates a propensity towards kyphotic orientation through the prosthesis likely as a result of intraoperative lordotic distraction. FSU angulation tends towards kyphosis and FSU height is decreased in the postoperative state from lack of anterior column support. Limitations of Bryan cervical disc arthroplasty should be carefully considered when reconstruction or maintenance of cervical lordosis is desirable.
Kobayashi, Seneki; Kubo, Toshikazu; Iwamoto, Yukihide; Fukushima, Wakaba; Sugano, Nobuhiko
2018-05-12
To identify modifiable factors related to post-operative dislocation and reoperation in patients with osteonecrosis of the femoral head (ONFH) in a large cohort. We studied 4995 hip arthroplasties: total hip arthroplasty (THA) was performed in 79% of patients; bipolar hemiarthroplasty (BP), 17%; total resurfacing arthroplasty (tRS), 3%; and hemi-resurfacing arthroplasty (hRS), 1%. A new type of BP (accounting for 49% of BPs) comprised a femoral component with a polished or smooth, small-diameter (approximately 10 mm) neck with a round or oval axial cut surface and no sharp corners. The infection rate was relatively low (0.56%) even though 58% of cases of ONFH were associated with systemic steroid use, a known risk factor for infection. Post-operative dislocation occurred in 4.3% of cases, with re-operation needed in 3.9%. The dislocation rate was related to surgery type: 5.2% in THA, 0.9% in BP, and 0% in tRS and hRS. Among total arthroplasties with six month or longer follow-up (3670 THAs and 159 tRSs), the risk factors for post-operative dislocation were younger (≤ 40 years) or older (≥ 62 years) age, higher body weight, posterolateral approach, and smaller prosthetic head diameter. Regarding the need for re-operation, higher body weight and surgery type were identified as risk factors. The relatively high dislocation rate of 5.2% in THA is a cause for concern. The identified risk factors for dislocation should be considered when selecting THA for treatment. Prosthesis survivorship in hRSs was inferior to that in BPs or THAs. Body weight also affected the survivorship of hip arthroplasties.
Variability of indication criteria in knee and hip replacement: an observational study
2010-01-01
Background Total knee (TKR) and hip (THR) replacement (arthroplasty) are effective surgical procedures that relieve pain, improve patients' quality of life and increase functional capacity. Studies on variations in medical practice usually place the indications for performing these procedures to be highly variable, because surgeons appear to follow different criteria when recommending surgery in patients with different severity levels. We therefore proposed a study to evaluate inter-hospital variability in arthroplasty indication. Methods The pre-surgical condition of 1603 patients included was compared by their personal characteristics, clinical situation and self-perceived health status. Patients were asked to complete two health-related quality of life questionnaires: the generic SF-12 (Short Form) and the specific WOMAC (Western Ontario and Mcmaster Universities) scale. The type of patient undergoing primary arthroplasty was similar in the 15 different hospitals evaluated. The variability in baseline WOMAC score between hospitals in THR and TKR indication was described by range, mean and standard deviation (SD), mean and standard deviation weighted by the number of procedures at each hospital, high/low ratio or extremal quotient (EQ5-95), variation coefficient (CV5-95) and weighted variation coefficient (WCV5-95) for 5-95 percentile range. The variability in subjective and objective signs was evaluated using median, range and WCV5-95. The appropriateness of the procedures performed was calculated using a specific threshold proposed by Quintana et al for assessing pain and functional capacity. Results The variability expressed as WCV5-95 was very low, between 0.05 and 0.11 for all three dimensions on WOMAC scale for both types of procedure in all participating hospitals. The variability in the physical and mental SF-12 components was very low for both types of procedure (0.08 and 0.07 for hip and 0.03 and 0.07 for knee surgery patients). However, a moderate-high variability was detected in subjective-objective signs. Among all the surgeries performed, approximately a quarter of them could be considered to be inappropriate. Conclusions A greater inter-hospital variability was observed for objective than for subjective signs for both procedures, suggesting that the differences in clinical criteria followed by surgeons when indicating arthroplasty are the main responsible factors for the variation in surgery rates. PMID:20977745
Variability of indication criteria in knee and hip replacement: an observational study.
Cobos, Raquel; Latorre, Amaia; Aizpuru, Felipe; Guenaga, Jose I; Sarasqueta, Cristina; Escobar, Antonio; García, Lidia; Herrera-Espiñeira, Carmen
2010-10-26
Total knee (TKR) and hip (THR) replacement (arthroplasty) are effective surgical procedures that relieve pain, improve patients' quality of life and increase functional capacity. Studies on variations in medical practice usually place the indications for performing these procedures to be highly variable, because surgeons appear to follow different criteria when recommending surgery in patients with different severity levels. We therefore proposed a study to evaluate inter-hospital variability in arthroplasty indication. The pre-surgical condition of 1603 patients included was compared by their personal characteristics, clinical situation and self-perceived health status. Patients were asked to complete two health-related quality of life questionnaires: the generic SF-12 (Short Form) and the specific WOMAC (Western Ontario and Mcmaster Universities) scale. The type of patient undergoing primary arthroplasty was similar in the 15 different hospitals evaluated.The variability in baseline WOMAC score between hospitals in THR and TKR indication was described by range, mean and standard deviation (SD), mean and standard deviation weighted by the number of procedures at each hospital, high/low ratio or extremal quotient (EQ5-95), variation coefficient (CV5-95) and weighted variation coefficient (WCV5-95) for 5-95 percentile range. The variability in subjective and objective signs was evaluated using median, range and WCV5-95. The appropriateness of the procedures performed was calculated using a specific threshold proposed by Quintana et al for assessing pain and functional capacity. The variability expressed as WCV5-95 was very low, between 0.05 and 0.11 for all three dimensions on WOMAC scale for both types of procedure in all participating hospitals. The variability in the physical and mental SF-12 components was very low for both types of procedure (0.08 and 0.07 for hip and 0.03 and 0.07 for knee surgery patients). However, a moderate-high variability was detected in subjective-objective signs. Among all the surgeries performed, approximately a quarter of them could be considered to be inappropriate. A greater inter-hospital variability was observed for objective than for subjective signs for both procedures, suggesting that the differences in clinical criteria followed by surgeons when indicating arthroplasty are the main responsible factors for the variation in surgery rates.
Advanced concepts in knee arthrodesis.
Wood, Jennifer H; Conway, Janet D
2015-03-18
The aim is to describe advanced strategies that can be used to diagnose and treat complications after knee arthrodesis and to describe temporary knee arthrodesis to treat infected knee arthroplasty. Potential difficult complications include nonunited knee arthrodesis, limb length discrepancy after knee arthrodesis, and united but infected knee arthrodesis. If a nonunited knee arthrodesis shows evidence of implant loosening or failure, then bone grafting the nonunion site as well as exchange intramedullary nailing and/or supplemental plate fixation are recommended. If symptomatic limb length discrepancy cannot be satisfactorily treated with a shoe lift, then the patient should undergo tibial lengthening over nail with a monolateral fixator or exchange nailing with a femoral internal lengthening device. If a united knee arthrodesis is infected, the nail must be removed. Then the surgeon has the option of replacing it with a long, antibiotic cement-coated nail. The authors also describe temporary knee arthrodesis for infected knee arthroplasty in patients who have the potential to undergo insertion of a new implant. The procedure has two goals: eradication of infection and stabilization of the knee. A temporary knee fusion can be accomplished by inserting both an antibiotic cement-coated knee fusion nail and a static antibiotic cement-coated spacer. These advanced techniques can be helpful when treating difficult complications after knee arthrodesis and treating cases of infected knee arthroplasty.
Advanced concepts in knee arthrodesis
Wood, Jennifer H; Conway, Janet D
2015-01-01
The aim is to describe advanced strategies that can be used to diagnose and treat complications after knee arthrodesis and to describe temporary knee arthrodesis to treat infected knee arthroplasty. Potential difficult complications include nonunited knee arthrodesis, limb length discrepancy after knee arthrodesis, and united but infected knee arthrodesis. If a nonunited knee arthrodesis shows evidence of implant loosening or failure, then bone grafting the nonunion site as well as exchange intramedullary nailing and/or supplemental plate fixation are recommended. If symptomatic limb length discrepancy cannot be satisfactorily treated with a shoe lift, then the patient should undergo tibial lengthening over nail with a monolateral fixator or exchange nailing with a femoral internal lengthening device. If a united knee arthrodesis is infected, the nail must be removed. Then the surgeon has the option of replacing it with a long, antibiotic cement-coated nail. The authors also describe temporary knee arthrodesis for infected knee arthroplasty in patients who have the potential to undergo insertion of a new implant. The procedure has two goals: eradication of infection and stabilization of the knee. A temporary knee fusion can be accomplished by inserting both an antibiotic cement-coated knee fusion nail and a static antibiotic cement-coated spacer. These advanced techniques can be helpful when treating difficult complications after knee arthrodesis and treating cases of infected knee arthroplasty. PMID:25793160
Casino, Daniela; Martelli, Sandra; Zaffagnini, Stefano; Lopomo, Nicola; Iacono, Francesco; Bignozzi, Simone; Visani, Andrea; Marcacci, Maurilio
2009-02-01
Surgical navigation systems are currently used to guide the surgeon in the correct alignment of the implant. The aim of this study was to expand the use of navigation systems by proposing a surgical protocol for intraoperative kinematics evaluations during knee arthroplasty. The protocol was evaluated on 20 patients, half undergoing unicondylar knee arthroplasty (UKA) and half undergoing posterior-substituting, rotating-platform total knee arthroplasty (TKA). The protocol includes a simple acquisition procedure and an original elaboration methodology. Kinematic tests were performed before and after surgery and included varus/valgus stress at 0 and 30 degrees and passive range of motion. Both UKA and TKA improved varus/valgus stability in extension and preserved the total magnitude of screw-home motion during flexion. Moreover, compared to preoperative conditions, values assumed by tibial axial rotation during flexion in TKA knees were more similar to the rotating patterns of UKA knees. The analysis of the anteroposterior displacement of the knee compartments confirmed that the two prostheses did not produce medial pivoting, but achieved a postoperative normal behavior. These results demonstrated that proposed intraoperative kinematics evaluations by a navigation system provided new information on the functional outcome of the reconstruction useful to restore knee kinematics during surgery.
Zhang, Hua; Xu, Zhongwei; Zhou, Aiguo; Yan, Wenlong; Zhao, Pei; Huang, Xiao; Zhang, Jian
2017-01-01
Abstract The aim of this study was to evaluate the efficacy of supplementary fixation in hip arthroplasty with the use of Kirschner-wires and tension band for geriatric patients suffering unstable intertrochanteric osteoporotic fractures. A total of 103 patients aged more than 75 years were recruited. A bipolar or total hip replacement was performed with additional application of Kirschner-wires and tension band, and the participants were followed up for 2 to 11 years. Physical component summary (PCS), mental component summary (MCS), visual analog scale (VAS), and Harris hip score were utilized to evaluate patients’ hip pain and function, as well as the mental condition postoperatively after 1.5 months, 3 months, 6 months, 1 year, and annually thereafter until the latest follow-up in 2015. Patients showed a significant improvement in all scores between 1.5 months and 1 year (P < 0.001), with the good efficacy lasting at least until the 2-year follow-up. None of the patients showed dislocation, implant loosening, or nonunion of the fracture throughout the follow-up period. In conclusion, it was beneficial to treat unstable intertrochanteric osteoporotic fractures in aged patients with hip arthroplasty coupled with Kirschner-wires and tension band. PMID:28072698
Glove perforation in hip and knee arthroplasty.
Demircay, Emre; Unay, Koray; Bilgili, Mustafa G; Alataca, Gulum
2010-11-01
The transmission of blood-borne pathogens during surgery is a major concern. Surgical gloves are the primary barrier between the surgeon and the patient. Surgical procedures that need manual handling of bony surfaces or sharp instruments have the highest risk of glove perforations. The frequencies and the sites of surgical glove perforations in arthroplasty procedures were assessed. We assessed the surgical glove perforations in total hip and knee arthroplasty procedures. Double standard latex gloves were used. A total of 983 outer and 511 inner gloves were tested. The gloves of all the surgical team members were tested for perforations during the first and second hours of surgery. There were 18.4% outer and 8.4% inner glove perforations. The most frequent site of perforation was the second digit of the nondominant hand (25.5%). We found that hip and knee arthroplasty had significantly more glove perforation risk for the surgeon in the first half of the operation rather than the second half, and 57.8% of the perforations were at the index finger and the thumb. Arthroplasty procedures still have high glove perforation rates despite the use of double gloving with frequent changes. Extra augmentation of the gloves in selected areas of the hand, in addition to double gloving, may be safer and more cost-effective than double gloving alone.
Cobalt toxicity after revision total hip replacement due to fracture of a ceramic head.
Pelayo-de Tomás, J M; Novoa-Parra, C; Gómez-Barbero, P
Symptomatic cobalt toxicity from a failed total hip replacement is a rare, but devastating complication. Potential clinical findings include cardiomyopathy, hypothyroidism, skin rash, visual and hearing impairment, polycythaemia, weakness, fatigue, cognitive impairment, and neuropathy. The case is presented of a 74year-old man in whom, after a ceramic-ceramic replacement and two episodes of prosthetic dislocation, it was decided to replace it with a polyethylene-metal total hip arthroplasty (THA). At 6months after the revision he developed symptoms of cobalt toxicity, confirmed by analytical determination (serum cobalt level=651.2μg/L). After removal of the prosthesis, the levels of chromium and cobalt in blood and urine returned to normal, with the patient currently being asymptomatic. It is recommended to use a new ceramic on ceramic bearing at revision, in order to minimise the risk of wear-related cobalt toxicity following breakage of ceramic components. Copyright © 2016 SECOT. Publicado por Elsevier España, S.L.U. All rights reserved.
Chytas, I D; Antonopoulos, C; Cheva, A; Givissis, P
2018-03-23
We asked whether either open reduction and internal fixation (ORIF) or radial head arthroplasty (RHA), common techniques used for the confrontation of displaced or comminuted radial head fractures, are correlated with cartilage wear of the capitulum. We hypothesized that neither ORIF nor RHA are correlated with capitellar cartilage wear. On 5 cadaveric elbow specimens, osteotomies were employed to simulate radial head comminuted fractures followed with ORIF by Herbert screws. Radial heads were also excised from other 5 cadaveric elbow specimens and were replaced by metallic monopolar implants. Finally 2 elbows were not operated and used as a control group. Custom-made rotary machines, working unstoppably, generated 700.000 pronation and supination forearm movements at an 110° arc of motion. The elbow joints were examined with pre- and postoperative Magnetic Resonance Imaging (MRI) scans and the articular surfaces of the capitula were resected and sent for histopathology study. In the 2 cadaveric elbows of the control group and the 4 elbows treated with ORIF no cartilage damage was found. The fifth one displayed cartilage fissures which were classified according to International Cartilage Repair Society (ICRS) grading system as grade I cartilage damage. On the contrary, all 5 elbows treated with RHA sustained complete cartilage loss, exposure of the subchondral bone and were classified as ICRS grade IV cartilage damage. Our study suggests that metallic monopolar RHA after a displaced or comminuted radial head fracture carries a high risk of rapidly evolving cartilage loss of the capitulum. Copyright © 2018 Elsevier Masson SAS. All rights reserved.
Experimental and failure analysis of the prosthetic finger joint implants
NASA Astrophysics Data System (ADS)
Naidu, Sanjiv H.
Small joint replacement arthroplasty of the hand is a well accepted surgical procedure to restore function and cosmesis in an individual with a crippled hand. Silicone elastomers have been used as prosthetic material in various small hand joints for well over three decades. Although the clinical science aspects of silicone elastomer failure are well known, the physical science aspects of prosthetic failure are scant and vague. In the following thesis, using both an animal model, and actual retrieved specimens which have failed in human service, experimental and failure analysis of silicone finger joints are presented. Fractured surfaces of retrieved silicone trapezial implants, and silicone finger joint implants were studied with both FESEM and SEM; the mode of failure for silicone trapezium is by wear polishing, whereas the finger joint implants failed either by fatigue fracture or tearing of the elastomer, or a combination of both. Thermal analysis revealed that the retrieved elastomer implants maintained its viscoelastic properties throughout the service period. In order to provide for a more functional and physiologic arthroplasty a novel finger joint (Rolamite prosthesis) is proposed using more recently developed thermoplastic polymers. The following thesis also addresses the outcome of the experimental studies of the Rolamite prosthesis in a rabbit animal model, in addition to the failure analysis of the thermoplastic polymers while in service in an in vivo synovial environment. Results of retrieved Rolamite specimens suggest that the use for thermoplastic elastomers such as block copolymer based elastomers in a synovial environment such as a mammalian joint may very well be limited.
Vanlommel, Jan; De Corte, Ronny; Luyckx, Jean Philippe; Anderson, Melissa; Labey, Luc; Bellemans, Johan
2017-01-01
Oxidized zirconium (OxZr) is produced by thermally driven oxidization creating an oxidized surface with the properties of a ceramic at the top of the Zr metal substrate. OxZr is much harder and has a lower coefficient of friction than cobalt-chrome (CoCr), both leading to better wear characteristics. We evaluated and compared damage to the cartilage of porcine patella plugs, articulating against OxZr vs CoCr. Our hypothesis was that, owing to its better wear properties, OxZr would damage cartilage less than CoCr. If this is true, OxZr might be a better material for the femoral component during total knee arthroplasty if the patella is not resurfaced. Twenty-one plugs from porcine patellae were prepared and tested in a reciprocating pin-on-disk machine while lubricated with bovine serum and under a constant load. Three different configurations were tested: cartilage-cartilage as the control group, cartilage-OxZr, and cartilage-CoCr. Macroscopic appearance, cartilage thickness, and the modified Mankin score were evaluated after 400,000 wear cycles. The control group showed statistically significant less damage than plugs articulating against both other materials. Cartilage plugs articulating against OxZr were statistically significantly less damaged than those articulating against CoCr. Although replacing cartilage by an implant always leads to deterioration of the cartilage counterface, OxZr results in less damage than CoCr. The use of OxZr might thus be preferable to CoCr in case of total knee arthroplasty without patella resurfacing. Copyright © 2016 Elsevier Inc. All rights reserved.
Tribology of total hip arthroplasty prostheses
Rieker, Claude B.
2016-01-01
Articulating components should minimise the generation of wear particles in order to optimize long-term survival of the prosthesis. A good understanding of tribological properties helps the orthopaedic surgeon to choose the most suitable bearing for each individual patient. Conventional and highly cross-linked polyethylene articulating either with metal or ceramic, ceramic-on-ceramic and metal-on-metal are the most commonly used bearing combinations. All combinations of bearing surface have their advantages and disadvantages. An appraisal of the individual patient’s objectives should be part of the assessment of the best bearing surface. Cite this article: Rieker CB. Tribology of total hip arthroplasty prostheses: what an orthopaedic surgeon should know. EFORT Open Rev 2016;1:52-57. DOI: 10.1302/2058-5241.1.000004. PMID:28461928
Schoellkopf, William J.; Ballard, David J.; Kaplan, Gary S.; James, Brent; Weinstein, James N.
2017-01-01
Background: To inform consumers and restrain health care cost growth, efforts to promote transparency and to reimburse for care episodes are accelerating in the United States. Objective: To compare characteristics and costs of 30-day episode of care for hip and knee replacement occurring in High Value Healthcare Collaborative (HVHC)-member hospitals to those occurring in like non–HVHC-member hospitals in the same 15 health care markets before interventions by HVHC members to improve health care value for those interventions. Research Design: This is a retrospective analysis of fee-for-service Medicare data from 2012 and 2013. Subjects: For hip arthroplasty, 4030 HVHC-member and 7572 non–HVHC-member, and for knee arthroplasty, 6542 HVHC-member and 13,900 non–HVHC-member fee-for-service Medicare patients aged 65 and older. Measures: Volumes, patient demographics, hospital stay characteristics, and acute and postacute care standardized costs for a 30-day episode of care. Results: HVHC-member hospitals differed from similar non–HVHC-member hospitals in the same health care markets when considering volumes of surgeries, patient demographics, Charlson scores, and patient distance to care during the index admission. There was little variation in acute care costs of hip or knee replacement surgery across health care markets; however, there was substantial variation in postacute care costs across those same markets. We saw less variation in postacute care costs within markets than across markets. Regression analyses showed that HVHC-member status was not associated with shorter lengths of stay, different complication rates, or lower total or postacute care costs for hip or knee replacement. Conclusions: Health care regions appear to be a more important predictor of episode costs of care than HVHC status. PMID:28319584
Shalhoub, Sami; Moschetti, Wayne E; Dabuzhsky, Leonid; Jevsevar, David S; Keggi, John M; Plaskos, Christopher
2018-05-14
The traditional goal of the gap-balancing method in total knee arthroplasty is to create equal and symmetric knee laxity throughout the arc of flexion. The purpose of this study was to (1) quantify the laxity in the native and the replaced knee throughout the range of flexion in gap-balancing total knee arthroplasty (TKA) and (2) quantify the precision in achieving a targeted gap profile throughout flexion using a robotic-assisted technique with active ligament tensioning. Robotic-assisted, gap-balancing TKA was performed in 14 cadaver specimens. The proximal tibia was resected, and the native tibiofemoral gaps were measured using a robotic tensioner that dynamically tensioned the soft-tissue envelope throughout the arc of flexion. The femoral implant was then aligned to balance the gaps at 0° and 90° of flexion. The postoperative gaps were then measured during final trialing with the robotic tensioner and compared with the planned gaps. The native gaps increased by 3.4 ± 1.7 mm medially and 3.7 ± 2.1 mm laterally from full extension to 20° of flexion (P < .001) and then remained consistent through the remaining arc of flexion. Gap balancing after TKA produced equal gaps at 0° and 90° of flexion, but the gap laxity in midflexion was 2-4 mm greater than at 0° and 90° (P < .001). The root mean square error between the planned gaps and actual measured postoperative gaps was 1.6 mm medially and 1.7 mm laterally throughout the range of motion. Aiming for equal gaps at 0° and 90° of flexion produced equal gaps in extension and flexion with larger gaps in midflexion. Consistent soft-tissue balance to a planned gap profile could be achieved by using controlled ligament tensioning in robotic-assisted TKA. Copyright © 2018 Elsevier Inc. All rights reserved.
The Effect of Advancing Age on Total Joint Replacement Outcomes
Noiseux, Nicolas; Linson, Eric; Cram, Peter
2015-01-01
Objective: To describe age-related differences in outcomes among older adults undergoing total hip arthroplasty (THA) and total knee arthroplasty (TKA). Design: Retrospective study. Participants: A total of 1792 patients who underwent primary THA or TKA at the University of Iowa Hospitals and Clinics between 2010 and 2013 were identified in the University HealthSystem Consortium Database and University of Iowa Orthopedics Joint Replacement Registry. Main Outcome Measures: Hospital length of stay (LOS), 30-day readmission rate, in-hospital mortality, number of days admitted to intensive care unit (ICU discharge disposition), in-hospital complications (pulmonary embolism, deep vein thrombosis, wound infection, hemorrhage, sepsis, or myocardial infarction), quality of life (measured using Short-Form 36 [SF-36]), discharge disposition (home, home with home health, nursing home, inpatient rehabilitation, transfer to another acute care hospital, and dead), and total patient level observed hospital cost (based on hospital charge information from each revenue code and estimated labor costs). Outcomes were compared in patients stratified by age and categorized by decade (ie, ≤50, 51-60, 61-70, 71-80, and ≥81). Results: A total of 871 THAs and 921 TKAs were performed. The mean age of our cohort was 60.5 years and 56.1% were women. In-hospital complication rates and ICU utilization progressively increased with increasing age. There was also a higher likelihood of skilled nursing facility placement and longer LOS. There was no increase in 30-day readmissions, mortality, or total cost. Improvements in patient reported outcomes (SF-36) scores were similar for all age-groups. Conclusions: Compared to younger patients, older THA and TKA recipients were more likely to experience postoperative complications, admission to the ICU, discharge to a skilled care facility, and had longer hospital LOS. Improvements in patient-related outcomes were similar across all age-groups. These findings may be helpful when counseling older patients regarding elective total joint arthroplasty. PMID:26328232
A new design concept for wrist arthroplasty.
Shepherd, D E T; Johnstone, A
2005-01-01
The wrist joint is frequently affected by arthritis, which leads to pain, loss of function and ultimately deformity. Various designs of wrist arthroplasty have been introduced to attempt to relieve pain and provide a functional range of motion. The first generation of wrist implant was a one-piece silicone elastomer. Later generations have designs that have two parts that articulate against each other. However, wrist implants have not achieved the same clinical success to date, compared with hip and knee implants, and there is a high revision rate associated with them. This paper describes a new design concept for wrist arthroplasty, based around the idea of combining the principles of an articulating implant with that of a flexible elastomer implant. The design consists of assembling a radial, carpal/metacarpal, plate and flexible parts together. The radial and carpal/metacarpal parts are to be made from ultra high molecular weight polyethylene. The bearing surfaces of the radial and carpal/metacarpal parts articulate against the flat surfaces of the plate, made from cobalt chrome molybdenum alloy. The radius on the bearing surface of the radial part enables flexion/extension, while the radius on the carpal/metacarpal surface enables radial/ulnar deviation. The articulation of the carpal/metacarpal part against the plate also allows for rotation as well as flexion/extension. The flexible part, made from Elast-Eon, which is a silicone polyurethane elastomer, is inserted through the hole of the plate and into the holes of the radial and carpal/metacarpal parts.
Spontaneous displacement of olecranon fracture through geode salvaged by elbow replacement.
Jaiswal, Anuj; Thakur, Raman; Relwani, Jaikumar; Ogufere, Wallace
2010-04-01
We present a case of pathological fracture of olecranon through a giant geode. Fracture was initially undisplaced and was treated conservatively. It later progressed to a transolecranon dislocation as a result of a pseudarthrosis at the fracture site. The patient presented 4 years later when she developed symptoms of ulnar nerve palsy. She was treated by a total elbow arthroplasty with ulnar nerve transposition. The current report highlights this unusual case and reviews the relevant literature.
Russo, Matthew W; Parks, Nancy L; Hamilton, William G
2017-10-01
Multimodal pain management has become the standard of care following total hip and knee replacement. The advantages include decreasing opioid consumption and its associated side effects, facilitating earlier mobilization, and faster return to function. An effective rapid recovery protocol includes the use of multiple different types of medications targeting each area of the pain pathway, preemptive analgesia, regional nerve blockade, and local infiltration analgesia. Copyright © 2017 Elsevier Inc. All rights reserved.
Hoggett, L; Cross, C; Helm, T
2017-12-01
Dislocation after total hip arthroplasty (THA) remains a significant complication of the procedure and is the third leading cause for revision THA. One technique for treatment of this complication is the use of the posterior lip augmentation device (PLAD). We describe our experience using the PLAD including complication rates. A retrospective review of 55 PLADs (54 patients) was carried out following identification from electronic theatre records. Basic patient demographics, operative records and radiographs were collected and reviewed and data was analysed using Microsoft Excel. Failure of the PLAD was defined as further operative intervention after PLAD insertion and included: dislocation, implant breakage, infection and revision of the THA for loosening of either component. 55 PLADs were implanted in 54 patients with an average age of 77 years. There was a significant preponderance of females and a variety of surgical approaches had been used for the original hip replacement, including trochanteric osteotomy, posterior and antero-lateral. 9 (16%) patients had recurrent dislocations,1 (2%) failed secondary to screw breakage, 3 (5%) had and infection requiring intervention and 2 (4%) underwent further revision for aseptic loosening of the femoral component. The overall failure rate was 25% with 14 patients requiring intervention post PLAD. Our results are inferior to other published results and indicate that the PLAD should be used with caution for recurrent dislocations of the Charnley hip replacement.
[Eradication of Staphylococcus aureus in carrier patients undergoing joint arthroplasty].
Barbero Allende, José M; Romanyk Cabrera, Juan; Montero Ruiz, Eduardo; Vallés Purroy, Alfonso; Melgar Molero, Virginia; Agudo López, Rosa; Gete García, Luis; López Álvarez, Joaquín
2015-02-01
Prosthetic joint infection (PJI) is a complication with serious repercussions and its main cause is Staphylococcus aureus. The purpose of this study is to determine whether decolonization of S.aureus carriers helps to reduce the incidence of PJI by S.aureus. An S.aureus screening test was performed on nasal carriers in patients undergoing knee or hip arthroplasty between January and December 2011. Patients with a positive test were treated with intranasal mupirocin and chlorhexidine soap 5 days. The incidence of PJI was compared with patients undergoing the same surgery between January and December 2010. A total of 393 joint replacements were performed in 391 patients from the control group, with 416 joint replacements being performed in the intervention group. Colonization study was performed in 382 patients (91.8%), of which 102 were positive (26.7%) and treated. There was 2 PJI due S.aureus compared with 9 in the control group (0.5% vs 2.3%, odds ratio [OR]: 0.2, 95% confidence interval [CI]: 0.4 to 2.3, P=.04). In our study, the detection of colonization and eradication of S.aureus carriers achieved a significant decrease in PJI due to S.aureus compared to a historical group. Copyright © 2013 Elsevier España, S.L.U. y Sociedad Española de Enfermedades Infecciosas y Microbiología Clínica. All rights reserved.
Fibrin tissue adhesive reduces postoperative blood loss in total knee arthroplasty.
Sabatini, Luigi; Trecci, Andrea; Imarisio, Daniele; Uslenghi, Marco Davide; Bianco, Giuseppe; Scagnelli, Roberto
2012-09-01
Blood transfusion is often required in total knee replacement; various methods of blood preservation have been studied. The best solution is to reduce the loss of blood during and after surgery. We designed this study to evaluate the hemostatic efficacy and safety of fibrin tissue adhesive (Quixil) in patients receiving total knee arthroplasty [low contact stress (LCS, DePuy, Warsaw, IN, US) cementless total knee replacement (TKR)] with a prospective, randomized, standard treatment controlled study. Thirty-five patients were randomized to receive treatment with fibrin tissue adhesive (treatment group), and 35 were randomized to be managed with postoperative blood recovery and reinfusion (control group). Blood loss in suction drain, decrease in hemoglobin values, and transfusions were recorded. A significant reduction in apparent total blood loss was detected in the treatment group compared with the control group. There was also a lower decrease in hemoglobin level, although this difference was not significant. When fibrin tissue adhesive was administered, the need for transfusions was lower. No major adverse events were recorded in our series. Fibrin tissue adhesive reduced blood loss in TKR and seemed to significantly reduce the need for blood transfusion. Fibrin tissue adhesive can be an appropriate solution to enhance hemostasis and vessel sealing at the operative site in TKR, in order to reduce blood loss after surgery and the risk of complications.
Tanikake, Yohei; Hayashi, Koji; Ogawa, Munehiro; Inagaki, Yusuke; Kawate, Kenji; Tomita, Tetsuya; Tanaka, Yasuhito
2016-12-01
A 72-year-old male patient underwent mobile-bearing posterior-stabilized total knee arthroplasty for osteoarthritis. He experienced a nontraumatic polyethylene tibial insert cone fracture 27 months after surgery. Scanning electron microscopy of the fracture surface of the tibial insert cone suggested progress of ductile breaking from the posterior toward the anterior of the cone due to repeated longitudinal bending stress, leading to fatigue breaking at the anterior side of the cone, followed by the tibial insert cone fracture at the anterior side of the cone, resulting in fracture at the base of the cone. This analysis shows the risk of tibial insert cone fracture due to longitudinal stress in mobile-bearing posterior-stabilized total knee arthroplasty in which an insert is designed to highly conform to the femoral component.
Cowie, Raelene M; Briscoe, Adam; Fisher, John; Jennings, Louise M
2016-01-01
PEEK-OPTIMA™ (Invibio Ltd, UK) has been considered as an alternative joint arthroplasty bearing material due to its favourable mechanical properties and the biocompatibility of its wear debris. In this study, the potential to use injection moulded PEEK-OPTIMA™ as an alternative to cobalt chrome in the femoral component of a total knee replacement was investigated in terms of its wear performance. Experimental wear simulation of three cobalt chrome and three PEEK-OPTIMA™ femoral components articulating against all-polyethylene tibial components was carried out under two kinematic conditions: 3 million cycles under intermediate kinematics (maximum anterior-posterior displacement of 5 mm) followed by 3 million cycles under high kinematic conditions (anterior-posterior displacement 10 mm). The wear of the GUR1020 ultra-high-molecular-weight polyethylene tibial components was assessed by gravimetric analysis; for both material combinations under each kinematic condition, the mean wear rates were low, that is, below 5 mm3/million cycles. Specifically, under intermediate kinematic conditions, the wear rate of the ultra-high-molecular-weight polyethylene tibial components was 0.96 ± 2.26 mm3/million cycles and 2.44 ± 0.78 mm3/million cycle against cobalt chrome and PEEK-OPTIMA™ implants, respectively (p = 0.06); under high kinematic conditions, the wear rates were 2.23 ± 1.85 mm3/million cycles and 4.44 ± 2.35 mm3/million cycles, respectively (p = 0.03). Following wear simulation, scratches were apparent on the surface of the PEEK-OPTIMA™ femoral components. The surface topography of the femoral components was assessed using contacting profilometry and showed a statistically significant increase in measured surface roughness of the PEEK-OPTIMA™ femoral components compared to the cobalt chrome implants. However, this did not appear to influence the wear rate, which remained linear over the duration of the study. These preliminary findings showed that PEEK-OPTIMA™ gives promise as an alternative bearing material to cobalt chrome alloy in the femoral component of a total knee replacement with respect to wear performance. PMID:27637723
Twice cutting method reduces tibial cutting error in unicompartmental knee arthroplasty.
Inui, Hiroshi; Taketomi, Shuji; Yamagami, Ryota; Sanada, Takaki; Tanaka, Sakae
2016-01-01
Bone cutting error can be one of the causes of malalignment in unicompartmental knee arthroplasty (UKA). The amount of cutting error in total knee arthroplasty has been reported. However, none have investigated cutting error in UKA. The purpose of this study was to reveal the amount of cutting error in UKA when open cutting guide was used and clarify whether cutting the tibia horizontally twice using the same cutting guide reduced the cutting errors in UKA. We measured the alignment of the tibial cutting guides, the first-cut cutting surfaces and the second cut cutting surfaces using the navigation system in 50 UKAs. Cutting error was defined as the angular difference between the cutting guide and cutting surface. The mean absolute first-cut cutting error was 1.9° (1.1° varus) in the coronal plane and 1.1° (0.6° anterior slope) in the sagittal plane, whereas the mean absolute second-cut cutting error was 1.1° (0.6° varus) in the coronal plane and 1.1° (0.4° anterior slope) in the sagittal plane. Cutting the tibia horizontally twice reduced the cutting errors in the coronal plane significantly (P<0.05). Our study demonstrated that in UKA, cutting the tibia horizontally twice using the same cutting guide reduced cutting error in the coronal plane. Copyright © 2014 Elsevier B.V. All rights reserved.
Brewster, D H; Stockton, D L; Reekie, A; Ashcroft, G P; Howie, C R; Porter, D E; Black, R J
2013-05-14
Release and dispersion of particles arising from corrosion and wear of total hip arthroplasty (THA) components has raised concerns about a possible increased risk of cancer. Concerns have been heightened by a recent revival in the use of metal-on-metal (MoM) hip prostheses. From a linked database of hospital discharge, cancer registration, and mortality records, we selected a cohort of patients who underwent primary THA (1990-2009) or primary resurfacing arthroplasty (mainly 2000-2009) in Scotland, with follow-up to the end of 2010. Available operation codes did not enable us to distinguish MoM THAs. Indirectly standardised incidence ratios (SIRs) were calculated for selected cancers with standardisation for age, sex, deprivation, and calendar period. The study cohort included 71 990 patients yielding 547 001 person-years at risk (PYAR) and 13 946 cancers diagnosed during follow-up. For the total period of observation combined, the risks of all cancers (SIR: 1.05; 95% CI: confidence interval 1.04-1.07), prostate cancer (SIR: 1.07; 95% CI: 1.01-1.14), and multiple myeloma (SIR: 1.22; 95% CI: 1.06-1.41) were increased. These modest increases in risk emerged in the context of effectively multiple tests of statistical significance, and may reflect inadequate adjustment for confounding factors. For 1317 patients undergoing primary resurfacing arthroplasty between 2000 and 2009 (PYAR=5698), the SIR for all cancers (n=39) was 1.23 (95% CI: 0.87-1.68). In the context of previous research, these results do not suggest a major cause for concern. However, the duration of follow-up of patients receiving recently introduced, new-generation MoM prostheses is too short to rule out a genuinely increased risk of cancer entirely.
Using Text Messaging in Long-Term Arthroplasty Follow-Up: A Pilot Study.
Blocker, Oliver; Bullock, Alison; Morgan-Jones, Rhidian; Ghandour, Adel; Richardson, James
2017-05-16
Patient-reported outcome measures (PROMs) and mobile technology have the potential to change the way patients are monitored following joint replacement surgery. The aim of this study was to determine the feasibility of text messaging to record PROMs in long-term follow-up of hip and knee arthroplasty. Our participants were 17 patients 2-years-plus post hip or knee arthroplasty attending clinic with a mobile telephone number on record. A simple PROM (Oswestry Very Short Form) was texted to the patient. Responses were compared to clinical, radiographic, and existing PROM findings. Patients were interviewed to discover their opinions on this use of texting. A total of 11 patients engaged with the text messaging. Reasons for not engaging included wrong numbers, physical barriers, and lack of understanding. A total of 8 patients attending clinic allowed comparison of text messaging with clinical findings. The average age was 70 years. A total of 4 patient text messaging responses matched clinical and radiographic findings; 3 also matched PROM scores collected in clinic. The 3 patients with mixed responses had abnormal clinical, radiographic, or PROM findings. One patient's text responses conflicted with clinical outcome. Analysis of patients' views showed a generally positive opinion: patients were happy to communicate with surgeons by text. Practical problems, PROM limitations, and trustworthiness of texting were highlighted. Engaging with changing technology creates challenges for patients and health care professionals. Despite this, our results suggest text messaging is a promising way to communicate with arthroplasty patients. Earlier integration of text communication in the patient pathway may be important and needs further research. ©Oliver Blocker, Alison Bullock, Rhidian Morgan-Jones, Adel Ghandour, James Richardson. Originally published in JMIR Research Protocols (http://www.researchprotocols.org), 16.05.2017.
Nistor, Dan-Viorel; Caterev, Sergiu; Bolboacă, Sorana-Daniela; Cosma, Dan; Lucaciu, Dan Osvald Gheorghe; Todor, Adrian
2017-11-01
We conducted this study to establish if the transition from a lateral approach (LA) to the direct anterior approach (DAA) for a low volume hip arthroplasty surgeon during the steep learning curve can be performed maintaining the muscle sparing approach of the DAA without increasing the complication rates. In this controlled, prospective, randomized clinical study we investigated 70 patients (35 DAA, 35 LA) with similar demographics that underwent a total hip arthroplasty. Assessment of the two approaches consisted of determining the invasiveness through serum markers for muscle damage (i.e. myoglobin, creatine kinase and lactate dehydrogenase), the operative parameters such as post-operative pain and rescue medication consumption, the component positioning and complication rates. Post-operative myoglobin levels were higher (p < 0.001) in the LA group (326.42 ± 84.91 ng/mL) as compared to the DAA group (242.80 ± 71.03 ng/mL), but with no differences regarding other biomarkers for muscle damage. Pain levels were overall lower in the DAA group, with a statistical and clinical difference during surgery day (p < 0.001) associated with lower (p < 0.001) rescue medication consumption (median 1 (1; 3) mg morphine vs. 3 (2; 4) mg morphine). Most patients in the LA group reported chronic post-operative pain throughout all three evaluated months, while the majority of patients in the DAA group reported no pain after week six. Component positioning did not differ significantly between groups and neither did complication rates. The DAA can be transitioned from the LA safely, without higher complication rates while maintaining its muscle spearing advantages when performed by a low volume hip arthroplasty surgeon.
The Survival of Total Knee Arthroplasty: Current Data from Registries on Tribology: Review Article.
Civinini, Roberto; Carulli, Christian; Matassi, Fabrizio; Lepri, Andrea Cozzi; Sirleo, Luigi; Innocenti, Massimo
2017-02-01
Polyethylene (PE) wear is a major contributor to implant loosening following total knee arthroplasty (TKA), and advanced bearings in TKA are being investigated with hopes of reducing or eliminate wear-related loosening. Currently, information on knee tribology is available from national joint registries and may be the best tools to evaluate the efficacy and safety of design innovations in joint arthroplasty. We performed a review of national joint registries trying to answer the following questions: "Which is the main factor directly related to revisions rate in TKA?" and "Are there new bearing options better than conventional ones?" A review was performed of all published annual reports of National Joint Registers, as well as of the literature. The search was carried out using and comparing the National Joint Registers. Current data from registries for total knee arthroplasty indicates that age is the major factor affecting the outcome of primary total knee replacement. The 10-year cumulative revision rate for non-cross-linked PE was 5.8% and for XLPE it was 3.5%. The effect of cross-linked polyethylene was more evident in the younger patients. The survival of the oxidized zirconium (OxZr) femoral component appears better when compared to a similar age group of patients with conventional group of prostheses. Our review suggests that the revision rates are half for the OxZr components compared to conventional CoCr femoral components. Age is the most relevant single factor related to revision rate. Cross-linked PE has a statistical lower revision rate at 10 years compared to conventional PE and, in the OxZr group, the revision rate is 2 times lower than Co-Cr in the same group of age.
Nussenbaum, Fernando D; Rodriguez-Quintana, David; Fish, Sara M; Green, David M; Cahill, Catherine W
2018-01-01
Total hip arthroplasty (THA) and total knee arthroplasty (TKA) are common procedures with a risk of complications. Attempting to minimize complications, our institution implemented preoperative screening criteria for patients undergoing elective total joint replacement. Our study aimed to determine if screening criteria lowered total complications and/or surgical site infections (SSI). Two groups of consecutive patients undergoing TKA and THA at a single Veterans Affairs facility were evaluated prior to and after implementation of screening criteria, 520 and 475 respectively. Screening criteria included hemoglobin A1c ≤7, hemoglobin ≥11, body mass index ≤35, and albumin ≥3.5. Groups were analyzed for demographics, preoperative comorbidities, and postoperative complications. Rates of total complications and SSI were compared. Average follow-up was at least 2 years with minimum of 1 year. Demographics and comorbidities outside the screening criteria were similar. Total complication rate was reduced from 35.4% to 14.8% (P < .01) after implementation of screening criteria. For TKA, total complications were reduced from 33.1% to 15.0% (P < .01) and for THA they were reduced from 42.4% to 14.2% (P < .01). SSI rates for combined TKA and THA were reduced from 4.4% to 1.3% (P < .01). For knees, SSI was reduced from 4.6% to 1.3% (P = .01) and was statistically significant. For THA, SSI decreased from 3.8% to 1.2% (P < .05). Our institution saw a statistically significant decrease in both SSI and total complications following implementation of preoperative screening criteria for elective TKA and THA. Published by Elsevier Inc.
Patient-reported outcome measures in arthroplasty registries
Bohm, Eric; Franklin, Patricia; Lyman, Stephen; Denissen, Geke; Dawson, Jill; Dunn, Jennifer; Eresian Chenok, Kate; Dunbar, Michael; Overgaard, Søren; Garellick, Göran; Lübbeke, Anne
2016-01-01
Abstract — The International Society of Arthroplasty Registries (ISAR) Patient-Reported Outcome Measures (PROMs) Working Group have evaluated and recommended best practices in the selection, administration, and interpretation of PROMs for hip and knee arthroplasty registries. The 2 generic PROMs in common use are the Short Form health surveys (SF-36 or SF-12) and EuroQol 5-dimension (EQ-5D). The Working Group recommends that registries should choose specific PROMs that have been appropriately developed with good measurement properties for arthroplasty patients. The Working Group recommend the use of a 1-item pain question (“During the past 4 weeks, how would you describe the pain you usually have in your [right/left] [hip/knee]?”; response: none, very mild, mild, moderate, or severe) and a single-item satisfaction outcome (“How satisfied are you with your [right/left] [hip/knee] replacement?”; response: very unsatisfied, dissatisfied, neutral, satisfied, or very satisfied). Survey logistics include patient instructions, paper- and electronic-based data collection, reminders for follow-up, centralized as opposed to hospital-based follow-up, sample size, patient- or joint-specific evaluation, collection intervals, frequency of response, missing values, and factors in establishing a PROMs registry program. The Working Group recommends including age, sex, diagnosis at joint, general health status preoperatively, and joint pain and function score in case-mix adjustment models. Interpretation and statistical analysis should consider the absolute level of pain, function, and general health status as well as improvement, missing data, approaches to analysis and case-mix adjustment, minimal clinically important difference, and minimal detectable change. The Working Group recommends data collection immediately before and 1 year after surgery, a threshold of 60% for acceptable frequency of response, documentation of non-responders, and documentation of incomplete or missing data. PMID:27228230
Kelly, Matthew P; Prentice, Heather A; Wang, Wei; Fasig, Brian H; Sheth, Dhiren S; Paxton, Elizabeth W
2018-07-01
Previous studies evaluating reasons for 30-day readmissions following total joint arthroplasty (TJA) may underestimate hospital-based utilization of healthcare resources during a patient's episode-of-care. We sought to identify common reasons for 90-day emergency department (ED) visits and hospital readmissions following primary elective unilateral TJA. Patients from July 1, 2012 through June 30, 2015 having primary elective TJA and at least one 90-day postoperative ED-only visit and/or readmission for any reason were identified using the Kaiser Permanente Total Joint Replacement Registry. Chart reviews for ED visits/readmissions included 13 surgical and 11 medical reasons. The 2344 total hips and 5520 total knees were analyzed separately. Incidence of at least one ED visit following total hip arthroplasty (THA) was 13.4% and 4.5% for readmissions. The most frequent reasons for ED visits were swelling (15.6%) and pain (12.8%); the most frequent reasons for readmissions were infection (12.5%) and unrelated elective procedures (9.0%). The incidence of at least one ED visit following total knee arthroplasty (TKA) was 13.8%, and the incidence of readmission was 5.5%. The most frequent reasons for ED visits were pain (15.8%) and swelling (15.6%); the most common readmission reasons were gastrointestinal (19.1%) and manipulation under anesthesia (9.4%). Swelling and pain related to the procedure were the most frequent reasons for 90-day ED visits after both THA and TKA. Readmissions were most commonly due to infection or unrelated procedures for THA and gastrointestinal or manipulation under anesthesia for TKA. Modifications to discharge protocols may help prevent or alleviate these issues, avoiding unnecessary hospital returns. Copyright © 2018 Elsevier Inc. All rights reserved.
Febrile response after knee and hip arthroplasty.
Shaw, J A; Chung, R
1999-10-01
Documentation of the normal fever response after total knee and hip replacement is important to avoid an unnecessary workup for sepsis, and to provide justification for early discharge (dictated by the current medical reimbursement climate) despite persistent postoperative fever. One hundred patients who underwent total knee arthroplasty and 100 patients who underwent total hip arthroplasty were reviewed, several of whom had extensive sepsis workups for evaluation of postoperative fever. No patient in this series had a documented joint infection. All patients were treated with warfarin for deep vein thombrosis prophylaxis. All patients used incentive spirometry and were started on ambulation training on postoperative Day 1. All were given antibiotic prophylaxis for 48 hours. The maximum daily postoperative temperature occurred in most patients on postoperative Day 1 and gradually leveled off toward normal by postoperative Day 5. Only one patient had a maximum temperature on postoperative Day 4 that was greater than that on postoperative Day 3. Patients undergoing revision procedures tended to have a more pronounced febrile response, but the differences were not statistically significant. No significant differences were seen between patients who had epidural anesthesia and patients who had general anesthesia. Seventeen patients had postoperative chest radiographs for evaluation of fever. None had significant atelectasis. The presence of a positive urine culture had no effect on the fever response, with most positive results being identified after the fever had returned toward normal. Postoperative fever after total joint arthroplasty is a normal inflammatory response. A workup for sepsis is not indicated in the perioperative period unless corroborating signs or symptoms are present. Early discharge is appropriate if the febrile response is decreasing progressively.
Miyatake, Naohisa; Sugita, Takehiko; Aizawa, Toshimi; Sasaki, Akira; Maeda, Ikuo; Kamimura, Masayuki; Fujisawa, Hirokazu; Takahashi, Atsushi
2016-09-01
Precise matching of the tibial component and resected bony surfaces and proper rotational implanting of the tibial component are crucial for successful total knee arthroplasty. We aimed to analyze the exact anthropometric proximal tibial data of Japanese patients undergoing total knee arthroplasty and correlate the measurements with the dimensions of current total knee arthroplasty systems. A total of 703 knees in 566 Japanese patients who underwent total knee arthroplasty for osteoarthritis were included. The bone resection in the proximal tibia was performed perpendicular to the tibial axis in the frontal plane. Measurements of the proximal tibia were intraoperatively obtained after proximal tibial preparation. There were significant positive correlations between the lateral anteroposterior and medial anteroposterior and mediolateral dimensions. A progressive decrease in the mediolateral/lateral anteroposterior ratio with an increasing lateral anteroposterior dimension or the mediolateral/anteroposterior ratio with an increasing anteroposterior dimension was observed. The lateral anteroposterior dimension was smaller than the medial anteroposterior dimension by a mean of 4.8 ± 2.0 mm. The proximal tibia exhibited asymmetry between the lateral and medial plateaus. A comparison of the morphological data and dimensions of the implants, one of which was a symmetric tibial component (NexGen) and the others were asymmetric (Genesis II and Persona), indicated that an asymmetric tibial component could be beneficial to maximize tibial plateau coverage. This study provided important reference data for designing a proper tibial component for Japanese people. The proximal tibial cut surface was asymmetric. There was wide dispersion in the lateral anteroposterior, medial anteroposterior, and mediolateral dimensions depending on the patient. Our data showed that the tibial components of the Genesis II and Persona rather than that of the NexGen may be preferable for Japanese people because of their asymmetric design. Copyright © 2016 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.
Ren, J T; Xu, C; Wang, J S; Liu, X L
2017-10-01
Objective: To evaluate the effects of three-dimensional printing patient-specific instrumentation(PSI) versus conventional instrumentation(CI) in the total knee arthroplasty. Methods: According to "patient-specific" , "patient-matched" , "custom" , "Instrumentation" , "Guide Instrumentation" , "cutting blocks" , "total knee arthroplasty" , "total knee replacement" , "TKA" and "TKR" , the literature on PubMed, EMbase, Cochrane library, CBM and WanFang were searched. According to the inclusion and exclusion criteria, the high quality randomized control trial (RCT) studies about three-dimensional (3D) printing patient-specific instrumentation versus conventional instrumentation in the total knee arthroplasty were collected. The post-operative limb mechanical axis outlier, the position of the components outlier, post-operative knee function, operative time, post-operative blood transfusion and complications were analyzed by RevMan 5.3 software. Results: A total of 13 high quality RCT studies were included. The results of Meta-analysis show that there were no statistical differences in the post-operative limb mechanical axis outlier( Z =0.55, P =0.58, 95% CI: 0.78 to 1.56), femoral coronal component outlier( Z =0.38, P =0.71, 95% CI: 0.69 to 1.72), tibia coronal component outlier( Z =1.95, P =0.05, 95% CI: 1.00 to 3.38), femoral rotation angle outlier( Z =0.36, P =0.72, 95% CI: 0.49 to 1.64), post-operative knee function( Z =1.18, P =0.24, 95% CI : -0.66 to 2.63), post-operative blood transfusions( Z =0.74, P =0.46, 95% CI: -0.10 to 0.05) and complications( Z =0.18, P =0.86, 95% CI: -0.07 to 0.05) between the PSI group and the CI group. But there are statistical differences in the operation time( Z =2.66, P =0.01, 95% CI: -15.97 to -2.41)and tibia sagittal component outlier ( Z =3.69, P =0.00, 95% CI: 1.43 to 3.18)between the PSI group and the CI group. Conclusions: In the primary total knee arthroplasty the PSI is not superior over the CI for the knee without severe knee varus or valgus deformity or contracture deformity, without the deformity around the knee and without the knee bone loss and obesity. The use of PSI in the primary total knee arthroplasty are not recommend.
Adjacent-level arthroplasty following cervical fusion.
Rajakumar, Deshpande V; Hari, Akshay; Krishna, Murali; Konar, Subhas; Sharma, Ankit
2017-02-01
OBJECTIVE Adjacent-level disc degeneration following cervical fusion has been well reported. This condition poses a major treatment dilemma when it becomes symptomatic. The potential application of cervical arthroplasty to preserve motion in the affected segment is not well documented, with few studies in the literature. The authors present their initial experience of analyzing clinical and radiological results in such patients who were treated with arthroplasty for new or persistent arm and/or neck symptoms related to neural compression due to adjacent-segment disease after anterior cervical discectomy and fusion (ACDF). METHODS During a 5-year period, 11 patients who had undergone ACDF anterior cervical discectomy and fusion (ACDF) and subsequently developed recurrent neck or arm pain related to adjacent-level cervical disc disease were treated with cervical arthroplasty at the authors' institution. A total of 15 devices were implanted (range of treated levels per patient: 1-3). Clinical evaluation was performed both before and after surgery, using a visual analog scale (VAS) for pain and the Neck Disability Index (NDI). Radiological outcomes were analyzed using pre- and postoperative flexion/extension lateral radiographs measuring Cobb angle (overall C2-7 sagittal alignment), functional spinal unit (FSU) angle, and range of motion (ROM). RESULTS There were no major perioperative complications or device-related failures. Statistically significant results, obtained in all cases, were reflected by an improvement in VAS scores for neck/arm pain and NDI scores for neck pain. Radiologically, statistically significant increases in the overall lordosis (as measured by Cobb angle) and ROM at the treated disc level were observed. Three patients were lost to follow-up within the first year after arthroplasty. In the remaining 8 cases, the duration of follow-up ranged from 1 to 3 years. None of these 8 patients required surgery for the same vertebral level during the follow-up period. CONCLUSIONS Artificial cervical disc replacement in patients who have previously undergone cervical fusion surgery appears to be safe, with encouraging early clinical results based on this small case series, but more data from larger numbers of patients with long-term follow-up are needed. Arthroplasty may provide an additional tool for the management of post-fusion adjacent-level cervical disc disease in carefully selected patients.
2013-01-01
Background Formal rehabilitation programs are often assumed to be required after total knee arthroplasty to optimize patient recovery. Inpatient rehabilitation is a costly rehabilitation option after total knee arthroplasty and, in Australia, is utilized most frequently for privately insured patients. With the exception of comparisons with domiciliary services, no randomized trial has compared inpatient rehabilitation to any outpatient based program. The Hospital Inpatient versus HOme (HIHO) study primarily aims to determine whether 10 days of post-acute inpatient rehabilitation followed by a hybrid home program provides superior recovery of functional mobility on the 6-minute walk test (6MWT) compared to a hybrid home program alone following total knee arthroplasty. Secondarily, the trial aims to determine whether inpatient rehabilitation yields superior recovery in patient-reported function. Methods/Design This is a two-arm parallel randomized controlled trial (RCT), with a third, non-randomized, observational group. One hundred and forty eligible, consenting participants who have undergone a primary total knee arthroplasty at a high-volume joint replacement center will be randomly allocated when cleared for discharge from acute care to either 10 days of inpatient rehabilitation followed by usual care (a 6-week hybrid home program) or to usual care. Seventy participants in each group (140 in total) will provide 80% power at a significance level of 5% to detect an increase in walking capacity from 400 m to 460 m between the Home and Inpatient groups, respectively, in the 6MWT at 6 months post-surgery, assuming a SD of 120 m and a drop-out rate of <10%. The outcome assessor will assess participants at 10, 26 and 52 weeks post-operatively, and will remain blind to group allocation for the duration of the study, as will the statistician. Participant preference for rehabilitation mode stated prior to randomization will be accounted for in the analysis together with any baseline differences in potentially confounding characteristics as required. Discussion The HIHO Trial will be the first RCT to investigate the efficacy of inpatient rehabilitation compared to any outpatient alternative following total knee arthroplasty. Trial registration U.S. National Institutes of Health Clinical Trials Registry (http://clinicaltrials.gov) ref: NCT01583153 PMID:24341348
Lee, Michael J; Dumonski, Mark; Phillips, Frank M; Voronov, Leonard I; Renner, Susan M; Carandang, Gerard; Havey, Robert M; Patwardhan, Avinash G
2011-11-01
A cadaveric biomechanical study. To investigate the biomechanical behavior of the cervical spine after cervical total disc replacement (TDR) adjacent to a fusion as compared to a two-level fusion. There are concerns regarding the biomechanical effects of cervical fusion on the mobile motion segments. Although previous biomechanical studies have demonstrated that cervical disc replacement normalizes adjacent segment motion, there is a little information regarding the function of a cervical disc replacement adjacent to an anterior cervical decompression and fusion, a potentially common clinical application. Nine cadaveric cervical spines (C3-T1, age: 60.2 ± 3.5 years) were tested under load- and displacement-control testing. After intact testing, a simulated fusion was performed at C4-C5, followed by C6-C7. The simulated fusion was then reversed, and the response of TDR at C5-C6 was measured. A hybrid construct was then tested with the TDR either below or above a single-level fusion and contrasted with a simulated two-level fusion (C4-C6 and C5-C7). The external fixator device used to simulate fusion significantly reduced range of motion (ROM) at C4-C5 and C6-C7 by 74.7 ± 8.1% and 78.1 ± 11.5%, respectively (P < 0.05). Removal of the fusion construct restored the motion response of the spinal segments to their intact state. Arthroplasty performed at C5-C6 using the porous-coated motion disc prosthesis maintained the total flexion-extension ROM to the level of the intact controls when used as a stand-alone procedure or when implanted adjacent to a single-level fusion (P > 0.05). The location of the single-level fusion, whether above or below the arthroplasty, did not significantly affect the motion response of the arthroplasty in the hybrid construct. Performing a two-level fusion significantly increased the motion demands on the nonoperated segments as compared to a hybrid TDR-plus fusion construct when the spine was required to reach the same motion end points. The spine with a hybrid construct required significantly less extension moment than the spine with a two-level fusion to reach the same extension end point. The porous-coated motion cervical prosthesis restored the ROM of the treated level to the intact state. When the porous-coated motion prosthesis was used in a hybrid construct, the TDR response was not adversely affected. A hybrid construct seems to offer significant biomechanical advantages over two-level fusion in terms of reducing compensatory adjacent-level hypermobility and also loads required to achieve a predetermined ROM.
Tribology of total hip arthroplasty prostheses: What an orthopaedic surgeon should know.
Rieker, Claude B
2016-02-01
Articulating components should minimise the generation of wear particles in order to optimize long-term survival of the prosthesis.A good understanding of tribological properties helps the orthopaedic surgeon to choose the most suitable bearing for each individual patient.Conventional and highly cross-linked polyethylene articulating either with metal or ceramic, ceramic-on-ceramic and metal-on-metal are the most commonly used bearing combinations.All combinations of bearing surface have their advantages and disadvantages. An appraisal of the individual patient's objectives should be part of the assessment of the best bearing surface. Cite this article: Rieker CB. Tribology of total hip arthroplasty prostheses: what an orthopaedic surgeon should know. EFORT Open Rev 2016;1:52-57. DOI: 10.1302/2058-5241.1.000004.
Subsequent Total Joint Arthroplasty After Primary Total Knee or Hip Arthroplasty
Sanders, Thomas L.; Maradit Kremers, Hilal; Schleck, Cathy D.; Larson, Dirk R.; Berry, Daniel J.
2017-01-01
Background: Despite the large increase in total hip arthroplasties and total knee arthroplasties, the incidence and prevalence of additional contralateral or ipsilateral joint arthroplasty are poorly understood. The purpose of this study was to determine the rate of additional joint arthroplasty after a primary total hip arthroplasty or total knee arthroplasty. Methods: This historical cohort study identified population-based cohorts of patients who underwent primary total hip arthroplasty (n = 1,933) or total knee arthroplasty (n = 2,139) between 1969 and 2008. Patients underwent passive follow-up through their medical records beginning with the primary total hip arthroplasty or total knee arthroplasty. We assessed the likelihood of undergoing a subsequent total joint arthroplasty, including simultaneous and staged bilateral procedures. Age, sex, and calendar year were evaluated as potential predictors of subsequent arthroplasty. Results: During a mean follow-up of 12 years after an initial total hip arthroplasty, we observed 422 contralateral total hip arthroplasties (29% at 20 years), 76 contralateral total knee arthroplasties (6% at 10 years), and 32 ipsilateral total knee arthroplasties (2% at 20 years). Younger age was a significant predictor of contralateral total hip arthroplasty (p < 0.0001), but not a predictor of the subsequent risk of total knee arthroplasty. During a mean follow-up of 11 years after an initial total knee arthroplasty, we observed 809 contralateral total knee arthroplasties (45% at 20 years), 31 contralateral total hip arthroplasties (3% at 20 years), and 29 ipsilateral total hip arthroplasties (2% at 20 years). Older age was a significant predictor of ipsilateral or contralateral total hip arthroplasty (p < 0.001). Conclusions: Patients undergoing total hip arthroplasty or total knee arthroplasty can be informed of a 30% to 45% chance of a surgical procedure in a contralateral cognate joint and about a 5% chance of a surgical procedure in noncognate joints within 20 years of initial arthroplasty. Increased risk of contralateral total knee arthroplasty following an initial total hip arthroplasty may be due to gait changes prior to and/or following total hip arthroplasty. The higher prevalence of bilateral total hip arthroplasty in younger patients may result from bilateral disease processes that selectively affect the young hip, such as osteonecrosis, or structural hip problems, such as acetabular dysplasia or femoroacetabular impingement. Level of Evidence: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence. PMID:28244910
A Systematic Literature Review of Three Modalities in Technologically Assisted TKA
Leone, William A.; Elson, Leah C.; Anderson, Christopher R.
2015-01-01
In effort to reduce the revision burden of total knee arthroplasty (TKA), industry emphasis has focused on replacing manual techniques—which are subject to variability—with technological implements. Unfortunately, technological innovation often continues before adequate time for critical evaluation has passed. Therefore, the purpose of this descriptive literature review was to collect a large sample of international data and report on the clinical and economic efficacy of three major types of technologically assisted TKA: navigation, patient-specific instrumentation, and sensorized trials. PMID:26664755
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hungerford, D.S.; Lennox, D.W.
1985-10-01
Early diagnosis of osteonecrosis by radiograph, bone scan, CT scan, magnetic resonance imaging (MRI), intraosseous pressure measurement, or intraosseous venogram can lead to early successful treatment. For early (Ficat stages I and II) osteonecrosis of the hip, core decompression can provide diagnostic confirmation and pain relief and may prevent progression of disease. For more advanced disease (Ficat stages II and IV), osteotomy, endoprosthetic or bipolar prosthetic replacement, total hip arthroplasty, and arthrodesis are surgical options.86 references.
Klemetti, Seija; Leino-Kilpi, Helena; Cabrera, Esther; Copanitsanou, Panagiota; Ingadottir, Brynja; Istomina, Natalja; Katajisto, Jouko; Papastavrou, Evridiki; Unosson, Mitra; Valkeapää, Kirsi
2015-12-01
The purpose of the study was to examine received and expected knowledge of patients with knee/hip arthroplasty in seven European countries. The goal was to obtain information for developing empowering patient education. The data were collected (during 2009-2012) from patients (n = 943) with hip/knee arthroplasty prior to scheduled preoperative education and before discharge with the Received Knowledge of hospital patient scale (RKhp) and Expected Knowledge of hospital patient scale (EKhp). Patients' knowledge expectations were high but the level of received knowledge did not correspond to expectations. The difference between received and expected knowledge was higher in Greece and Sweden compared with Finland (p < .0001, p < .0001), Spain (p < .0001, p = .001), and Lithuania (p = .005, p = .003), respectively. Patients' knowledge expectations are important in tailoring patient education. To achieve high standards in the future, scientific research collaboration on empowering patient education is needed between European countries. © The Author(s) 2014.
Prosthetic replacement for proximal humeral fractures.
Kontakis, George; Tosounidis, Theodoros; Galanakis, Ioannis; Megas, Panagiotis
2008-12-01
The ideal management of complex proximal humeral fractures continues to be debatable. Evolution of proximal humeral fracture management, during the past decade, led to the implementation of many innovations in surgical treatment. Even though the pendulum of treatment seems to swing towards new trends such as locked plating, hemiarthroplasty remains a valid and reliable option that serves the patient's needs well. Hemiarthroplasty is indicated for complex proximal humeral fractures in elderly patients with poor bone stock and when internal fixation is difficult or unreliable. Hemiarthroplasty provides a better result when it is performed early post-injury. Stem height, retroversion and tuberosity positioning are technical aspects of utmost importance. Additionally reverse total shoulder arthroplasty is an alternative new modality that can be used as a primary solution in selected patients with proximal humeral fracture treatment. Failed hemiarthroplasty and fracture sequelae can be successfully managed with reverse total shoulder arthroplasty. Individual decision-making and tailored treatment that takes into consideration the personality of the fracture and the patient's characteristics should be used.
Late dislocation of rotating platform in New Jersey Low-Contact Stress knee prosthesis.
Huang, Chun-Hsiung; Ma, Hon-Ming; Liau, Jiann-Jong; Ho, Fang-Yuan; Cheng, Cheng-Kung
2002-12-01
Five patients with late rotational dislocation of the rotating platform bearing in the New Jersey Low-Contact Stress total knee arthroplasty are reported. The prostheses had functioned well for 8 to 12 years before failure. Preoperative radiographs showed asymmetric femorotibial joint spaces. Entrapment of the dislocated bearing in three patients and spontaneous reduction of the dislocated bearing in another two patients were seen at revision. Femorotibial ligamentous instability was found after reduction. The retrieved polyethylene bearings showed advanced wear and cold flow deformities and the thickness was reduced. The revision arthroplasty was accomplished by replacement with a thicker bearing element. Progressive femorotibial ligament laxity and reduction of the thickness of polyethylene with wearing break down the originally well-balanced soft tissue tension of the knee. The rotational degree of the rotating platform bearing is unrestricted, which may result in late dislocation. Polyethylene wear is unavoidable in knee prostheses using metal contact with polyethylene even with a mobile-bearing design. Efforts to reduce polyethylene wear are mandatory.
Nesslage, Roman; Radtke, Kerstin; Hohloch, Lisa; Flörkemeier, Thilo; Windhagen, Henning; Lewinski, Gabriela von
2017-04-01
Background Total hip arthroplasty (THA) is very frequently performed. Despite low complication rates, revisions play an important clinical and economical role. The aim of this study was to identify comorbid diseases of patients undergoing primary THA and their potential influence on the survival of hip replacements. Patients/Material and Methods A total of 867 patients were included in this retrospective study. All revisions were reviewed that took place at our hospital within one year of primary implantation of THA. Comorbid diseases were detected by administrative data, using the Elixhauser definition, which includes thirty diseases. The Cox regression model and Fisher's exact test were used to examine correlations between comorbidities and risk of revision. Results 41 Patients required re-operation within the first year of surgery. The presence of one or more of the analysed comorbidities was associated with a greater risk of revision. Deficiency anemia, obesity, drug abuse, alcohol abuse, fluid and electrolyte disorders and peripheral vascular disorders were associated with increased risk of revision (p < 0.05 for all comparisons). The total number of comorbidities and specific comorbid diseases was independently associated with an increased risk of re-operation within the first year of total hip arthroplasty. This information could be helpful in pre- and post-operative risk adjustment and patient selection. Georg Thieme Verlag KG Stuttgart · New York.
Davis, Edward T; Pagkalos, Joseph; Gallie, Price A M; Macgroarty, Kelly; Waddell, James P; Schemitsch, Emil H
2015-01-01
Optimal component alignment in total knee arthroplasty has been associated with better functional outcome as well as improved implant longevity. The ability to align components optimally during minimally invasive (MIS) total knee replacement (TKR) has been a cause of concern. Computer navigation is a useful aid in achieving the desired alignment although it is limited by the error during the manual registration of landmarks. Our study aims to compare the registration process error between a standard and a MIS surgical approach. We hypothesized that performing the registration error via an MIS approach would increase the registration process error. Five fresh frozen lower limbs were routinely prepared and draped. The registration process was performed through an MIS approach. This was then extended to the standard approach and the registration was performed again. Two surgeons performed the registration process five times with each approach. Performing the registration process through the MIS approach was not associated with higher error compared to the standard approach in the alignment parameters of interest. This rejects our hypothesis. Image-free navigated MIS TKR does not appear to carry higher risk of component malalignment due to the registration process error. Navigation can be used during MIS TKR to improve alignment without reduced accuracy due to the approach.
The incidence of total hip arthroplasty after hip arthroscopy in osteoarthritic patients
2010-01-01
Objective To assess the incidence of total hip arthroplasty (THA) in osteoarthritic patients who were treated by arthroscopic debridement and to evaluate factors that might influence the time interval from the first hip arthroscopy to THA. Design Retrospective clinical series Methods Follow-up data and surgical reports were retrieved from 564 records of osteoarthritic patients that have had hip arthroscopy between the years 2002 to 2009 with a mean follow-up time of 3.2 years (range, 1-6.4 years). The time interval between the first hip arthroscopy to THA was modelled as a function of patient age; level of cartilage damage; procedures performed and repeated arthroscopies with the use of multivariate regression analysis. Results Ninety (16%) of all participants eventually required THA. The awaiting time from the first arthroscopy to a hip replacement was found to be longer in patients younger than 55 years and in a milder osteoarthritic stage. Patients that experienced repeated hip scopes had a longer time to THA than those with only a single procedure. Procedures performed concomitant with debridement and lavage did not affect the time interval to THA. Conclusions In our series of arthroscopic treatment of hip osteoarthritis, 16% required THA over a period of 7 years. Factors that influence the time to arthroplasty were age, degree of osteoarthritis and recurrent procedures. PMID:20670440
Metal-on-Metal Hip Resurfacing Arthroplasty
Sehatzadeh, S; Kaulback, K; Levin, L
2012-01-01
Background Metal-on-metal (MOM) hip resurfacing arthroplasty (HRA) is in clinical use as an appropriate alternative to total hip arthroplasty in young patients. In this technique, a metal cap is placed on the femoral head to cover the damaged surface of the bone and a metal cup is placed in the acetabulum. Objectives The primary objective of this analysis was to compare the revision rates of MOM HRA using different implants with the benchmark set by the National Institute of Clinical Excellence (NICE). The secondary objective of this analysis was to review the literature regarding adverse biological effects associated with implant material. Review Methods A literature search was performed on February 13, 2012, to identify studies published from January 1, 2009, to February 13, 2012. Results The revision rates for MOM HRA using 6 different implants were reviewed. The revision rates for MOM HRA with 3 implants met the NICE criteria, i.e., a revision rate of 10% or less at 10 years. Two implants had short-term follow-ups and MOM HRA with one of the implants failed to meet the NICE criteria. Adverse tissue reactions resulting in failure of the implants have been reported by several studies. With a better understanding of the factors that influence the wear rate of the implants, adverse tissue reactions and subsequent implant failure can be minimized. Many authors have suggested that patient selection and surgical technique affect the wear rate and the risk of tissue reactions. The biological effects of high metal ion levels in the blood and urine of patients with MOM HRA implants are not known. Studies have shown an increase in chromosomal aberrations in patients with MOM articulations, but the clinical implications and long-term consequences of this increase are still unknown. Epidemiological studies have shown that patients with MOM HRA implants did not have an overall increase in mortality or risk of cancer. There is insufficient clinical data to confirm the teratogenicity of MOM implants in humans. Conclusions Metal-on-metal HRA can be beneficial for appropriately selected patients, provided the surgeon has the surgical skills required for performing this procedure. Plain Language Summary There are many young patients with hip diseases who need to have hip replacement surgery. Although a traditional hip replacement is an acceptable procedure for these patients, some surgeons prefer using a newer technique in young patients called hip resurfacing. In this technique, instead of removing the head of the femoral bone, a metal cap is placed on the femoral head to cover the damaged surface of the bone and a metal cup is placed in the hip socket, similar to the cups used in traditional hip replacement. The analysis of the revision rates (i.e., how soon and in how many patients the surgery needs to be redone) and safety of resurfacing implants showed that generally these implants can last 10 years or more for the majority of young people. Good outcomes can be expected when skilled surgeons perform the surgery in properly selected patients. However, since these implants are made of metal (cobalt and chromium alloy), there is concern about excess metal debris production due to friction between the 2 metal components leading to high levels of metal ions in the blood and urine of patients. The production of metal debris may result in inflammation in the joint or development of a benign soft tissue mass leading to implant failure. However, it has been shown that this risk can be reduced by proper positioning of the implant and the careful selection of patients for this procedure. Little is known about the long-term biological effects of high levels of metal ions in the blood and urine of patients who have received metal implants. There is concern about potential increases in the risk of cancer and the risk of fetal abnormalities, but these effects have not been established yet. However, since cobalt and chromium can pass the placental barrier, implants that are not metal-on-metal are recommended for women at childbearing ages if they need a hip replacement. PMID:23074429
Simon, Peter; Gupta, Anil; Pappou, Ioannis; Hussey, Michael M; Santoni, Brandon G; Inoue, Nozomu; Frankle, Mark A
2015-03-01
Glenoid component loosening in total shoulder arthroplasty may be prevented by component placement on a congruent and adequate bony surface. Glenoid subchondral bone density (SBD) variability may be correlated with this concept. This study analyzed the 3-dimensional distribution of glenoid SBD in total shoulder arthroplasty patients with osteoarthritis. Three-dimensional computed tomography osteoabsorptiometry (CT-OAM) was performed in 42 men (21 with eccentric and 21 with concentric wear patterns) with glenohumeral arthritis. Glenoid SBD was measured from the joint surface based on 5 clinically relevant topographic zones. The correlation of the wear pattern with the SBD distribution was investigated. The glenoid subarticular layers could be separated into distinct regions: calcified cartilage (≤ 1.5 mm), subchondral plate (2-4.5 mm) and cancellous bone (≥ 5 mm). There were significant differences in SBD among these layers within and between patients with concentric and eccentric wear patterns. In concentric glenoids, the SBD distribution was homogeneous, with greater mineralization in the central zone, 1,749.1 ± 162.3 Hounsfield units (HU) (at 2.5 mm), compared with the posterior, anterior, and superior zones (P < .001). In the eccentric group, the SBD distribution was inhomogeneous. Mineralization was greatest in the posterior zone, 1,739.0 ± 172.6 HU (at 2.5 mm), followed by the inferior zone, 1,722.1 ± 186.6 HU (at 3 mm). This study represents the first study using CT-OAM to evaluate the 3-dimensional SBD distribution of the glenoid vault for different arthritic wear patterns. The study findings indicate that the SBD distribution is dependent on (1) depth from the articular surface, (2) topographic zone, and (3) wear pattern. CT-OAM may be an effective tool to assist in preoperative planning for shoulder arthroplasty. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Posterior slope of the tibial implant and the outcome of unicompartmental knee arthroplasty.
Hernigou, Philippe; Deschamps, Gerard
2004-03-01
Laboratory studies have suggested that the sagittal displacements permitted by a knee replacement are influenced by the posterior slope of the tibial implant. The effect of the posterior slope of the tibial implant on the outcome of unicompartmental arthroplasty is not well known. The purpose of the present study was to assess the effect of the posterior slope on the long-term outcome of unicompartmental arthroplasty in knees with intact and deficient anterior cruciate ligaments. We retrospectively reviewed the results of ninety-nine unicompartmental arthroplasties after a mean duration of follow-up of sixteen years. At the time of the arthroplasty, the anterior cruciate ligament was considered to be normal in fifty knees, damaged in thirty-one, and absent in eighteen. At the most recent follow-up, we measured the posterior tibial slope and the anterior tibial translation on standing lateral radiographs. The anteroposterior stability of seventy-seven knees that had not been revised by the time of the most recent follow-up was evaluated clinically. In the group of seventy-seven knees that had not been revised by the time of the most recent follow-up, there was a significant linear relationship between anterior tibial translation (mean, 3.7 mm) and posterior tibial slope (mean, 4.3 degrees ) (p < 0.01). The mean posterior slope of the tibial implant was significantly less in the group of seventy-seven knees without loosening of the implant than it was in the group of seventeen knees with loosening of the implant (p < 0.05). Five ruptures of the anterior cruciate ligament occurred in knees in which the ligament had been considered to be normal at the time of implantation; the posterior tibial slope in these five knees was > or = 13 degrees. Clinical evaluation revealed normal or nearly normal anteroposterior stability at the time of the most recent follow-up in all sixty-six unrevised knees in which the anterior cruciate ligament had been present at the time of implantation. Of the eighteen knees in which the anterior cruciate ligament had been absent at the time of the arthroplasty, eleven still had the implant in situ at the time of the most recent follow-up; the mean posterior tibial slope in these eleven knees was <5 degrees. Seven knees in which the anterior cruciate ligament had been absent at the time of the arthroplasty were revised. In these knees, the tibial prosthesis was implanted with a posterior slope of >8 degrees. These findings suggest that >7 degrees of posterior slope of the tibial implant should be avoided, particularly if the anterior cruciate ligament is absent at the time of implantation. An intact anterior cruciate ligament, even when partly degenerated, was associated with the maintenance of normal anteroposterior stability of the knee for an average of sixteen years following unicompartmental knee arthroplasty. Prognostic study, Level II-1 (retrospective study). See Instructions to Authors for a complete description of levels of evidence.
Indications for MARS-MRI in Patients Treated With Metal-on-Metal Hip Resurfacing Arthroplasty.
Connelly, James W; Galea, Vincent P; Matuszak, Sean J; Madanat, Rami; Muratoglu, Orhun; Malchau, Henrik
2018-06-01
Currently, there are no universally accepted guidelines on when to obtain metal artifact reduction sequence magnetic resonance imaging (MARS-MRI) in metal-on-metal (MoM) hip resurfacing arthroplasty (HRA) patients. Our primary aims were to identify which patient and clinical factors are predictive of adverse local tissue reaction (ALTR) and create an algorithm for indicating MARS-MRI in patients with Articular Surface Replacement (ASR) HRA. The secondary aim was to compare our algorithm to existing guidelines on when to perform MARS-MRI in MoM HRA patients. The study cohort consisted of 182 patients with unilateral ASR HRA from a prospective, multicenter study. Subjects received MARS-MRI at a mean of 7.8 years from surgery, regardless of symptoms. We determined which variables were predictive of ALTR and generated cutoffs for each variable. Finally, we created an algorithm to predict ALTR and indicate MARS-MRI in ASR HRA patients using these cutoffs and compared it to existing guidelines. We found high blood cobalt (Co) (odds ratio = 1.070; P = .011) and high blood chromium (Cr) (odds ratio = 1.162; P = .002) to be significant predictors of ALTR presence. Our algorithm using a blood Co cutoff of 1.15 ppb and a Cr cutoff of 1.09 ppb achieved 96.6% sensitivity and 35.3% specificity in predicting ALTR, which outperformed the existing guidelines. Blood Co and Cr levels are predictive of ALTR in ASR HRA patients. Our algorithm considering blood Co and Cr levels predicts ALTR in ASR HRA patients with higher sensitivity than previously established guidelines. Copyright © 2018 Elsevier Inc. All rights reserved.
Cervical hybrid arthroplasty with 2 unique fusion techniques.
Cardoso, Mario J; Mendelsohn, Audra; Rosner, Michael K
2011-07-01
Multilevel cervical arthroplasty achieved using the Prestige ST disc can be challenging and often unworkable. An alternative to this system is a hybrid technique composed of alternating total disc replacements (TDRs) and fusions. In the present study, the authors review the safety and radiological outcomes of cervical hybrid arthroplasty in which the Prestige ST disc is used in conjunction with 2 unique fusion techniques. After obtaining institutional review board approval, the authors completed a retrospective review of all hybrid cervical constructs in which the Prestige ST disc was used between August 2007 and November 2009 at the Walter Reed Army Medical Center. A Prestige ST total disc replacement was performed in 119 patients. Thirty-one patients received a hybrid construct defined as a TDR and fusion (TDR-anterior cervical decompression and fusion [ACDF]) or as 2 TDRs separated by a fusion (TDR-ACDF-TDR). A resorbable plate and graft system (Mystique) or stand-alone interbody spacer (Prevail) was implanted at the fusion levels. Plain radiographs were compared and evaluated for cervical lordosis, range of motion, implant complications, development of adjacent-level disease, and pseudarthrosis. In addition, charts were reviewed for clinical complications related to the index surgery. Thirty-one patients (18 men and 13 women; mean age 50 years, range 32-74 years) received a hybrid construct. All patients were diagnosed with radiculopathy and/or myelopathy. Twenty-four patients received a 2-level and 7 a 3-level hybrid construct. In 2 patients in whom a 2-level hybrid construct was implanted, a noncontiguous TDR was also performed. The mean clinical and radiological follow-up duration was 18 months. There was no significant difference in preoperative (19.3° ± 13.3°) and postoperative (19.7° ± 10.5°) cervical lordosis (p = 0.48), but there was a significant decrease in range in motion (from 50.0° ± 11.8° to 38.9° ± 12.7°) (p = 0.003). There were no instances of screw backout, implant dislodgement, progressive kyphosis, formation of heterotopic bone, pseudarthrosis, or symptomatic adjacent-level disease. Seven patients had dysphasia and 1 patient had vocal cord paralysis at 6 weeks. By 3 months, both the dysphasia and the vocal cord paralysis were resolved in all patients. Hybrid cervical arthroplasty involving the placement of a Prestige ST disc and either the Mystique resorbable plate or Prevail stand-alone interbody device is a safe and effective alternative to multilevel fusion for the management of cervical radiculopathy and myelopathy.
[Total knee arthroplasty by lateral parapatellar approach for valgus knee].
Zhou, Dian-ge; Zhang, Bin; Kou, Bo-long; Lü, Hou-shan
2007-07-17
To investigate the effect of lateral parapatellar approach in total knee arthroplasty (TKA) of valgus knee. Lateral parapatellar approach of total knee arthroplasty was applied in 8 patients (10 knees) with severe valgus osteoarthritis knee (bilateral in 2 cases and unilateral in 6 cases), with the valgus angle > 15 degrees , 1 male (1 knee) and 7 females (9 knee), aged 68.2 (58 - 79), 7 cases (9 knees) being of the Krackow type I and 1 case (1 knee) of the Krackow type I, I. After incision of the skin through lateral knee, ilio-tibial band was prolonged by apple pie arthroplasty. The joint capsule was cut open laterally 2 - 4 cm from the para-patellar edge. Soft tissue balance was performed by releasing I - T band in Gerdy tubercle, lateral collateral ligament and poster-lateral capsule from the femur and tibial side. Valgus angle of distal femur cutting were five degree. Whiteside line and trans-epicondylar line were used as AP rotational cutting reference. All patellar of the group were resurfaced. Capsule closure is completed with the knee flexed. The expanded deep lateral soft tissue sleeve (coronal Z-plasty) is sutured with the medial retinaculum sleeve (superficial layer). Follow-up was conducted for 19.6 months (1 - 51 months). Seven cases (9 knees) were replaced by posterior stabilized cemented prostheses (TC-Dynamic, PLUS), one case (1 knee) was replaced by RT prosthesis (RT-PLUS(TM) Solution, PLUS). After operation, the valgus deformity of all patients was corrected and all patients could walk 100 m with or without the help of walking holders. The average range of motion (ROM) was improved from the pre-operative. 95.6 degrees (85 degrees - 110 degrees ) to the post-operative 117.1 degrees (100 degrees - 125 degrees ). The average femorotibial angle (FTA) was corrected from the pre-operative. 27.6 degrees (20 degrees - 40 degrees ) to the post-operative 6.8 degrees (5 degrees - 9 degrees ). The Knee Score System (KSS) score and functional score were improved from the pre-operative 22.7 points (9 - 48 points) and 26.5 points (12 - 55 points) to the post-operative 86.4 points (85 - 95 points) and 89.1 points (80 - 95 points) respectively. Follow-up showed that the FTA remained unchanged and the knee stability of all patients was good. Through lateral approach, "Z" plasty of the capsule can release the lateral structure and decrease the pressure of common peroneal nerve. For TKR with moderate to severe fixed valgus knee, lateral approach is an effective way to correct the deformity.
The effects of modern cementing techniques on the longevity of total hip arthroplasty.
Poss, R; Brick, G W; Wright, R J; Roberts, D W; Sledge, C B
1988-07-01
Modern prosthetic design and cementing techniques have dramatically improved femoral component fixation. Compared to studies reported in the 1970s, the incidence of radiographic loosening for periods up to 5 years postoperatively has been reduced by at least a factor of 10. These results are the benchmark by which alternative forms of femoral component fixation must be measured. With the likelihood of increased longevity of total hip arthroplasty resulting from improved fixation, the problems of wear debris from the bearing surfaces and loss of bone stock with time will become preeminent.
Ansari, Farzana; Lee, Taylor; Malito, Louis; Martin, Audrey; Gunther, Stephen B; Harmsen, Samuel; Norris, Tom R; Ries, Mike; Van Citters, Douglas; Pruitt, Lisa
2016-07-01
The longevity of total shoulder replacement is primarily limited by the performance of the ultrahigh-molecular-weight polyethylene (UHMWPE) glenoid component in vivo. Variations in glenoid design (conformity, thickness), biomechanics (joint kinematics), and UHMWPE material selection (sterilization, cross-linking) distinguish total shoulder replacements from hip and knee arthroplasty devices. These variables can lead to severe mechanical failures, including gross fracture. Sixteen retrieved glenoids with severe fracture were analyzed. The explant cohort included 3 material groups (gamma-sterilized Hylamer; gamma-sterilized UHMWPE; and gas plasma-sterilized, remelted, highly cross-linked UHMWPE [HXL]) and a range of conformities (0- to 10-mm radial mismatch). Analysis included fractography (optical and scanning electron microscopy) and Fourier transform infrared spectroscopy for oxidative analysis. Fracture primarily occurred along the exterior rim for all 16 explants. Fourier transform infrared analysis and fractography revealed significant oxidative embrittlement for all gamma-sterilized glenoids. Fatigue striations and internal flaws were evident on the fracture surface of the HXL glenoid, with little oxidation detected. Fracture initiated at the external rim of all devices. Elevated oxidation levels and visible material distortion for representative gamma-sterilized conventional and Hylamer devices suggest oxidative embrittlement as a driving force for crack inception and subsequent fracture. Brittle fracture of theHXL glenoid resulted from a combination of elevated contact stress due to a nonconforming surface, an internal flaw, and reduced resistance to fatigue crack growth. This demonstrates that glenoid fracture associated with oxidation has not been eliminated with the advent of modern materials (HXL) in the shoulder domain. Basic Science Study; Implant Retrieval Study. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Murray, David W; MacLennan, Graeme S; Breeman, Suzanne; Dakin, Helen A; Johnston, Linda; Campbell, Marion K; Gray, Alastair M; Fiddian, Nick; Fitzpatrick, Ray; Morris, Richard W; Grant, Adrian M
2014-03-01
In the late 1990s, new developments in knee replacement were identified as a priority for research within the NHS. The newer forms of arthroplasty were more expensive and information was needed on their safety and cost-effectiveness. The Knee Arthroplasty Trial examined the clinical effectiveness and cost-effectiveness of four aspects of knee replacement surgery: patellar resurfacing, mobile bearings, all-polyethylene tibial components and unicompartmental replacement. This study comprised a partial factorial, pragmatic, multicentre randomised controlled trial with a trial-based cost-utility analysis which was conducted from the perspective of the NHS and the patients treated. Allocation was computer generated in a 1 : 1 ratio using a central system, stratified by eligible comparisons and surgeon, minimised by participant age, gender and site of disease. Surgeons were not blinded to allocated procedures. Participants were unblinded if they requested to know the prosthesis they received. The setting for the trial was UK secondary care. Patients were eligible for inclusion if a decision had been made for them to have primary knee replacement surgery. Patients were recruited to comparisons for which the surgeon was in equipoise about which type of operation was most suitable. Patients were randomised to receive a knee replacement with the following: patellar resurfacing or no patellar resurfacing irrespective of the design of the prosthesis used; a mobile bearing between the tibial and femoral components or a bearing fixed to the tibial component; a tibial component made of either only high-density polyethylene ('all polyethylene') or a polyethylene bearing fixed to a metal backing plate with attached stem; or unicompartmental or total knee replacement. The primary outcome was the Oxford Knee Score (OKS). Other outcomes were Short Form 12; EuroQol 5D; intraoperative and postoperative complications; additional surgery; cost; and cost-effectiveness. Patients were followed up for a median of 10 years; the economic evaluation took a 10-year time horizon, discounting costs and quality-adjusted life-years (QALYs) at 3.5% per annum. A total of 116 surgeons in 34 centres participated and 2352 participants were randomised: 1715 in patellar resurfacing; 539 in mobile bearing; 409 in all-polyethylene tibial component; and 34 in the unicompartmental comparisons. Of those randomised, 345 were randomised to two comparisons. We can be more than 95% confident that patellar resurfacing is cost-effective, despite there being no significant difference in clinical outcomes, because of increased QALYs [0.187; 95% confidence interval (CI) -0.025 to 0.399] and reduced costs (-£104; 95% CI -£630 to £423). We found no definite advantage or disadvantage of mobile bearings in OKS, quality of life, reoperation and revision rates or cost-effectiveness. We found improved functional results for metal-backed tibias: complication, reoperation and revision rates were similar. The metal-backed tibia was cost-effective (particularly in the elderly), costing £35 per QALY gained. The results provide evidence to support the routine resurfacing of the patella and the use of metal-backed tibial components even in the elderly. Further follow-up is required to assess the stability of these findings over time and to inform the decision between mobile and fixed bearings. Current Controlled Trials ISRCTN45837371. This project was funded by the NIHR Health Technology Assessment programme and the orthopaedic industry. It will be published in full in Health Technology Assessment; Vol. 18, No. 19. See the NIHR Journals Library website for further project information.
Do modern total knee replacements offer better value for money? A health economic analysis.
Hamilton, David F; Clement, Nicholas D; Burnett, Richard; Patton, James T; Moran, Mathew; Howie, Colin R; Simpson, A H R W; Gaston, Paul
2013-11-01
Cost effectiveness is an increasingly important factor in today's healthcare environment, and selection of arthroplasty implant is not exempt from such concerns. Quality adjusted life years (QALYs) are the typical tool for this type of evaluation. Using this methodology, joint arthroplasty has been shown to be cost effective; however, studies directly comparing differing prostheses are lacking. Data was gathered in a single-centre prospective double-blind randomised controlled trial comparing the outcome of modern and traditional knee implants, using the Short Form 6 dimensional (SF-6D) score and quality adjusted life year (QALY) methodology. There was significant improvement in the SF-6D score for both groups at one year (p < 0.0001). The calculated overall life expectancy for the study cohort was 15.1 years, resulting in an overall QALY gain of 2.144 (95% CI 1.752-2.507). The modern implant group demonstrated a small improvement in SF-6D score compared to the traditional design at one year (0.141 versus 0.143, p = 0.94). This difference resulted in the modern implant costing £298 less per QALY at one year. This study demonstrates that modern implant technology does not influence the cost-effectiveness of TKA using the SF-6D and QALY methodology. This type of analysis however assesses health status, and is not sensitive to joint specific function. Evolutionary design changes in implant technology are thus unlikely to influence QALY analysis following joint replacement, which has important implications for implant procurement.
Tibesku, C O; Innocenti, B; Wong, P; Salehi, A; Labey, L
2012-02-01
Long-term success of contemporary total knee replacements relies to a large extent on proper implant alignment. This study was undertaken to test whether specimen-matched cutting blocks based on computed axial tomography (CT) scans could provide accurate rotational alignment of the femoral component. CT scans of five fresh frozen full leg cadaver specimens, equipped with infrared reflective markers, were used to produce a specimen-matched femoral cutting block. Using those blocks, the bone cuts were made to implant a bi-compartmental femoral component. Rotational alignment of the components in the horizontal plane was determined using an optical measurement system and compared with all relevant rotational reference axes identified on the CT scans. Average rotational alignment for the bi-compartmental component in the horizontal plane was 1.9° (range 0°-6.3°; standard deviation 2.6°). One specimen that showed the highest deviation from the planned alignment also featured a completely degraded medial articular surface. The CT-based specimen-matched cutting blocks achieved good rotational alignment accuracy except for one specimen with badly damaged cartilage. In such cases, imaging techniques that visualize the cartilage layer might be more suitable to design cutting blocks, as they will provide a better fit and increased surface support.
Slane, Josh; Vivanco, Juan; Rose, Warren; Ploeg, Heidi-Lynn; Squire, Matthew
2015-03-01
Prosthetic joint infection is one of the most serious complications that can lead to failure of a total joint replacement. Recently, the rise of multidrug resistant bacteria has substantially reduced the efficacy of antibiotics that are typically incorporated into acrylic bone cement. Silver nanoparticles (AgNPs) are an attractive alternative to traditional antibiotics resulting from their broad-spectrum antimicrobial activity and low bacterial resistance. The purpose of this study, therefore, was to incorporate metallic silver nanoparticles into acrylic bone cement and quantify the effects on the cement's mechanical, material and antimicrobial properties. AgNPs at three loading ratios (0.25, 0.5, and 1.0% wt/wt) were incorporated into a commercial bone cement using a probe sonication technique. The resulting cements demonstrated mechanical and material properties that were not substantially different from the standard cement. Testing against Staphylococcus aureus and Staphylococcus epidermidis using Kirby-Bauer and time-kill assays demonstrated no antimicrobial activity against planktonic bacteria. In contrast, cements modified with AgNPs significantly reduced biofilm formation on the surface of the cement. These results indicate that AgNP-loaded cement is of high potential for use in primary arthroplasty where prevention of bacterial surface colonization is vital. Copyright © 2014 Elsevier B.V. All rights reserved.
Ravi, Bheeshma; Croxford, Ruth; Reichmann, William M; Losina, Elena; Katz, Jeffrey N; Hawker, Gillian A
2012-10-01
The rates of total joint arthroplasty (TJA) of the hip and knee have increased in North America over the last decade. While initially designed for elderly patients (>70 years of age), several reports suggest that an increasing number of younger patients are undergoing joint replacements. This suggests that more people are meeting the indication for TJA earlier in their lives. Alternatively, it might indicate a broadening of the indications for TJA. We used the administrative databases available at the Healthcare Cost and Utilization Project (HCUP) and the Institute for Clinical Evaluative Sciences (ICES) to determine the rates of TJA of the hip and knee in the United States, and Ontario, Canada, respectively. We determined the crude rates of THA and TKA in both areas for four calendar years (2001, 2003, 2005 and 2007). We also calculated the age- and sex-standardised rates of THA and TKA in both areas for each time period. We compared the age distribution of TJA recipients between the US and Ontario, and within each area over time. The crude and standardised rates of THA and TKA increased over time in both the US and Ontario. The crude rates of THA were higher in the US in 2001 and 2003, but were not significantly different from the rate in Ontario in 2005 and 2007. The crude rates of TKA were consistently higher in the US for all time periods. In addition, the US consistently had more THA and TKA recipients in 'younger' age categories (<60 years of age). While the age- and sex-standardised rates of TKA were greater in the US in all time periods, the relative increase in rates from 2001 to 2007 was greater in Ontario (US - 59%, Ontario - 73%). For both the US and Ontario, there was a significant shift in the demographic of THA and TKA recipients to younger patients (p < 0.0001). The utilisation of primary hip and knee arthroplasty has increased substantially in both the US and Ontario in the period from 2001 to 2007. This increase has been predominantly in knee replacements. The demographics of joint replacement recipients has become younger, with substantial increases in the prevalence of patients <60 years old amongst TJA recipients, and significant increases in the incidence of TJA in these age groups in the general population, in both the US and Ontario. Copyright © 2012 Elsevier Ltd. All rights reserved.
Tiusanen, Hannu; Sarantsin, Pjotor; Stenholm, Miika; Mattie, Ryan; Saltychev, Mikhail
2016-07-01
To evaluate the trajectory of the change in range of motion after reverse shoulder joint replacement during 3-year follow-up among patients with rheumatoid arthritis. Retrospective cohort longitudinal study of 76 shoulder replacements performed in a university clinic. The range of shoulder motion was assessed by a physiotherapist using a manual goniometer with 5-degree precision before the surgery and 1, 3, 6, 12, and 36 months postoperatively. The shapes of the regression curves suggest that the improvement or decline observed in joint motion was happening mostly during the first year after surgery. After 1 year, the trajectories become flat and they remained unchanged until the end of follow-up. After shoulder joint replacement, the range of shoulder motion showed substantial changes during the first year only. This should be taken into account when scheduling control visits, planning rehabilitation, and predicting the use of community services after the surgery.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kickuth, Ralph, E-mail: ralph.kickuth@insel.ch; Anderson, Suzanne; Peter-Salonen, Kristiina
2006-12-15
Joint hemorrhages are very common in patients with severe hemophilia. Inhibitors in patients with hemophilia are allo-antibodies that neutralize the activity of the clotting factor. After total knee replacement, rare intra-articular bleeding complications might occur that do not respond to clotting factor replacement. We report a 40-year-old male with severe hemophilia A and high responding inhibitors presenting with recurrent knee joint hemorrhage after bilateral knee prosthetic surgery despite adequate clotting factor treatment. There were two episodes of marked postoperative hemarthrosis requiring extensive use of subsititution therapy. Eleven days postoperatively, there was further hemorrhage into the right knee. Digital subtraction angiographymore » diagnosed a complicating pseudoaneurysm of the inferior lateral geniculate artery and embolization was successfully performed. Because clotting factor replacement therapy has proved to be excessively expensive and prolonged, especially in patients with inhibitors, we recommend the use of cost-effective early angiographic embolization.« less
Marcus-Aiyeku, Ulanda; DeBari, Margaret; Salmond, Susan
2015-01-01
In 2030, when baby boomers reach 65 years of age and represent 18% of the population, it is anticipated that 67 million adults will have a diagnosis of arthritis increasing the demand for total hip and knee arthroplasty. With the growing emphasis on patient- and family-centered care, the aim of this project was to assess the patient experience of patients and families throughout the entire spectrum of the total joint replacement service line care at a university regional trauma hospital. A shadowing methodology as defined by the Institute for Health Improvement was utilized. Eight patient/family groups undergoing total joint replacements were shadowed. The mapped care experience included time, caregiver, activity, shadower observations, and impressions. Findings revealed inconsistencies in the delivery of patient- and family-centered care. Communication and interactions were predominantly provider-centric, with a focus on care routines versus the patient and family, and anticipation that care would be medically directed.
Minimum distraction gap: how much ankle joint space is enough in ankle distraction arthroplasty?
Fragomen, Austin T; McCoy, Thomas H; Meyers, Kathleen N; Rozbruch, S Robert
2014-02-01
The success of ankle distraction arthroplasty relies on the separation of the tibiotalar articular surfaces. The purpose of this study was to find the minimum distraction gap needed to ensure that the tibiotalar joint surfaces would not contact each other with full weight-bearing while under distraction. Circular external fixators were mounted to nine cadaver ankle specimens. Each specimen was then placed into a custom-designed load chamber. Loads of 0, 350, and 700N were applied to the specimen. Radiographic joint space was measured and joint contact pressure was monitored under each load. The external fixator was then sequentially distracted, and the radiographic joint space was measured under the three different loads. The experiment was stopped when there was no joint contact under 700N of load. The radiographic joint space was measured and the initial (undistracted) radiographic joint space was subtracted from it yielding the distraction gap. The minimum distraction gap (mDG) that would provide total unloading was calculated. The average mDG was 2.4 mm (range, 1.6 to 4.0 mm) at 700N of load, 4.4 mm (range, 3.7 to 5.8 mm) at 350N of load, and 4.9 mm (range, 3.7 to 7.0 mm) at 0N of load. These results suggest that if the radiographic joint space of on a standing X-ray of an ankle undergoing distraction arthroplasty shows a minimum of 5.8 mm of DG, then there will be no contact between joint surfaces during full weight-bearing. Therefore, 5 mm of radiographic joint space, as recommended historically, may not be adequate to prevent contact of the articular surfaces during weight-bearing.
Lawrence, T; Moskal, J T; Diduch, D R
1999-07-01
It has often been hospital policy to send all resected specimens obtained during a total hip or knee arthroplasty for histological evaluation. This practice is expensive and may be unnecessary. We sought to determine the ability of surgeons to diagnose primary joint conditions correctly, and we attempted to identify any possible risks to the patient resulting from the omission of routine histological evaluation of specimens at the surgeon's discretion. Our objective was to ascertain whether routine histological evaluation could be safely omitted from the protocol for primary hip and knee arthroplasty without compromising the care of the patient. A total of 1388 consecutive arthroplasties in 1136 patients were identified from a database of primary total hip and knee arthroplasties that was prospectively maintained by the senior one of us. Follow-up data obtained at a mean of 5.5 years (range, two to ten years) were available after 92 percent (1273) of the 1388 arthroplasties. The preoperative diagnosis was determined from the history, findings on clinical examination, and radiographs. The intraoperative diagnosis was determined by gross inspection of joint fluid, articular cartilage, synovial tissue, and the cut surfaces of resected specimens. The combination of the preoperative and intraoperative diagnoses was considered to be the surgeon's clinical diagnosis. All resected specimens were sent for routine histological evaluation, and a pathological diagnosis was made. Attention was given to whether a discrepancy between the surgeon's clinical diagnosis and the pathological diagnosis altered the management of the patient. The original diagnoses were updated with use of annual radiographs and clinical assessments. The cost of histological examination of specimens obtained at arthroplasty was determined by consultation with hospital administration, accounting, and pathology department personnel. A pathological fracture or an impending fracture was diagnosed preoperatively and confirmed intraoperatively during twelve of the 1388 arthroplasties. Histological analysis demonstrated malignancy in specimens obtained during eleven of these arthroplasties and evidence of a benign rheumatoid geode in the specimen obtained during the twelfth arthroplasty. The preoperative and intraoperative diagnoses made before and during the remaining 1376 arthroplasties were benign conditions, which were confirmed histologically in all patients. No diagnosis changed during the follow-up period. As demonstrated by a comparison with the histological diagnosis, the surgeon's clinical diagnosis of malignancy had a sensitivity of 100 percent (95 percent confidence interval, 74.0 to 100 percent), a specificity of 99.9 percent (95 percent confidence interval, 99.6 to 100 percent), a positive predictive value of 91.7 percent (95 percent confidence interval, 64.6 to 98.5 percent), and a negative predictive value of 100 percent (95 percent confidence interval, 99.7 to 100 percent). There was a discrepancy between the preoperative and intraoperative diagnoses associated with eleven arthroplasties. All eleven intraoperative diagnoses were correct, as confirmed histologically. Excluding the patients who had a pathological or impending fracture, the accuracy of the surgeon's preoperative diagnosis was 99.2 percent (95 percent confidence interval, 98.6 to 99.5 percent). When the intraoperative and preoperative diagnoses were combined, the accuracy was 100 percent (95 percent confidence interval, 99.7 to 100 percent). Histological evaluation at our hospital resulted in total charges, including hospital costs and professional fees, of $196.27 and a mean total reimbursement of $102.59 per evaluation. In our series of 1136 patients with 1388 arthroplasties, these costs could have been eliminated for all but the twelve patients who had a suspected malignant lesion and the one patient in whom pigmented villonodular synovitis was found. (ABSTRACT
Hartmann, Albrecht; Hannemann, Franziska; Lützner, Jörg; Seidler, Andreas; Drexler, Hans; Günther, Klaus-Peter; Schmitt, Jochen
2013-01-01
Introduction The use of metal-on-metal (MoM) total hip arthroplasty (THA) increased in the last decades. A release of metal products (i.e. particles, ions, metallo-organic compounds) in these implants may cause local and/or systemic adverse reactions. Metal ion concentrations in body fluids are surrogate measures of metal exposure. Objective To systematically summarize and critically appraise published studies concerning metal ion concentrations after MoM THA. Methods Systematic review of clinical trials (RCTs) and epidemiological studies with assessment of metal ion levels (cobalt, chromium, titanium, nickel, molybdenum) in body fluids after implantation of metalliferous hip replacements. Systematic search in PubMed and Embase in January 2012 supplemented by hand search. Standardized abstraction of pre- and postoperative metal ion concentrations stratified by type of bearing (primary explanatory factor), patient characteristics as well as study quality characteristics (secondary explanatory factors). Results Overall, 104 studies (11 RCTs, 93 epidemiological studies) totaling 9.957 patients with measurement of metal ions in body fluids were identified and analyzed. Consistently, median metal ion concentrations were persistently elevated after implantation of MoM-bearings in all investigated mediums (whole blood, serum, plasma, erythrocytes, urine) irrespective of patient characteristics and study characteristics. In several studies very high serum cobalt concentrations above 50 µg/L were measured (detection limit typically 0.3 µg/L). Highest metal ion concentrations were observed after treatment with stemmed large-head MoM-implants and hip resurfacing arthroplasty. Discussion Due to the risk of local and systemic accumulation of metallic products after treatment with MoM-bearing, risk and benefits should be carefully balanced preoperatively. The authors support a proposed „time out“ for stemmed large-head MoM-THA and recommend a restricted indication for hip resurfacing arthroplasty. Patients with implanted MoM-bearing should receive regular and standardized monitoring of metal ion concentrations. Further research is indicated especially with regard to potential systemic reactions due to accumulation of metal products. PMID:23950923
Dahm, P O; Nitescu, P V; Appelgren, L K; Curelaru, I D
1998-01-01
There is at present no reliable method for long-term treatment of severe pain following complications of total hip arthroplasty. We explored the long-term use of continuous intrathecal opioid/bupivacaine analgesia in a case not amendable to corrective surgery. A 77-year-old woman, having a total hip arthroplasty, developed refractory nociceptive-neuropathic pain located at the ventral and dorsal aspects of the left hip. Radiographs showed a mandarine-sized intrapelvic mass of bone cement adhering to the roof of the acetabular cup. Further surgery had been declined by the surgeon and by the patient. An 18-gauge Portex intrathecal catheter was inserted, and an intrathecal infusion of 4.75 mg/mL bupivacaine and 0.015 mg/mL buprenorphine was started from a portable Pharmacia-Deltec (St. Paul, Minnesota) pump. The mean daily doses during the treatment period (more than 6 years up to now) were 37 mg for bupivacaine and 0.114 mg for buprenorphine. The intrathecal treatment gave the patient 85-100% pain relief. The patient could transport herself in a wheelchair, was able to perform her own hygiene, receive visits, read, watch television, and also shop and visit restaurants. There has been no need to replace the intrathecal catheter. Intrathecal infusion of opioid/bupivacaine can provide satisfactory long-term analgesia in patients with refractory pain from the hip joint.
Post-acute care disparities in total joint arthroplasty.
Lan, Roy H; Kamath, Atul F
2017-09-01
Understanding the socioeconomic factors that influence hospitalization and post-discharge metrics after joint replacement is important for identifying key areas of improvement in the delivery of orthopaedic care. An institutional administrative data set of 2869 patients from an academic arthroplasty referral center was analyzed to quantify the relationship between socioeconomic factors and post-acute rehabilitation care received, length of stay, and cost of care. The study used International Classification of Disease, ninth edition coding in order to identify cohorts of patients who received joint arthroplasty of the knee and hip between January 2007 and May 2015. The study found that females (odds ratio [OR], 2.07; 95% confidence interval [CI], 1.74-2.46), minorities (OR, 2.11; 95% CI, 1.78-2.51), and non-private insurance holders (OR, 1.56; 95% CI, 1.26-1.94) were more likely to be assigned to institutional care after discharge. The study also found that minorities (OR, 1.45; 95% CI, 1.24-1.70) and non-private insurance holders (OR, 1.43; 95% CI, 1.16-1.77) are more likely to exhibit longer length of stay. Mean charges were higher for males when compared to females ($80,010 vs $74,855; P < .001), as well as total costs ($19,910 vs $18,613; P = .001). Socioeconomic factors such as gender, race, and insurance status should be further explored with respect to healthcare policies seeking to influence quality of care and health outcomes.
Bilateral Total Hip Arthroplasty: 1-Stage or 2-Stage? A Meta-Analysis.
Shao, Hongyi; Chen, Chi-Lung; Maltenfort, Mitchell G; Restrepo, Camilo; Rothman, Richard H; Chen, Antonia F
2017-02-01
Total hip arthroplasty (THA) is one of the most successful orthopedic surgeries performed in the last 50 years. However, controversies still exist between conducting 1- or 2-stage bilateral THA. Using PubMed, Ovid, Embase, and Cochrane library databases, we searched for papers written between January 1995 and October 2015 that contained the following search terms: "one-stage or two-stage" or "simultaneous or staged," and "hip" and "arthroplasty or replacement." A meta-analysis was conducted with the collected pooled data about major and minor systemic complications, surgical complications, and other perioperative data associated with 1- and 2-stage bilateral THA. Statistical analysis was performed by the Mantel-Haenszel method, and the fixed effect model was used to analyze data. There were 13 studies with 17,762 patients who underwent 1-stage bilateral THA and 46,147 patients who underwent 2-stage bilateral THA. One-stage bilateral THA had a lower risk of major systemic complications, less deep venous thrombosis, and shorter operative time compared with 2-stage bilateral THA. There were no significant differences in death, pulmonary embolism, cardiovascular complication, infections, minor complications, and other surgical complications between procedures. One-stage bilateral THA was superior to 2-stage bilateral THA in terms of major systemic complication, deep venous thrombosis, and surgical time compared with 2-stage bilateral THA. However, this study does not encourage performing 1-stage over 2-stage bilateral THA. Higher evidence level studies are necessary for further analysis. Copyright © 2016 Elsevier Inc. All rights reserved.
Castorina, Sergio; Guglielmino, Claudia; Castrogiovanni, Paola; Szychlinska, Marta Anna; Ioppolo, Francesco; Massimino, Paolo; Leonardi, Pietro; Maci, Christian; Iannuzzi, Maurizio; Di Giunta, Angelo; Musumeci, Giuseppe
2017-01-01
Summary Background During the last years, programs to enhance postoperative recovery and decrease morbidity after total knee arthroplasty, have been developed across a variety of surgical procedures and referred to as “Fast-Track Surgery”. In this study we aimed to find some answers in the management of osteoarthritic patients subjected to total knee arthroplasty, by using the Fast-Track methodology. To this purpose we evaluated parameters such as early mobilization of patients, better pain management, bleeding, possible complications, reduced hospitalization time, an overall improved recovery and patient satisfaction. Methods 132 patients were selected, of which, 95 treated with “Fast Track” method and 37 treated with traditional method (control group). All the patients were hospitalized and underwent the same rehabilitation program for the first three days after surgery. Results In both groups, the parameters of pain and deformity demonstrated the most rapid improvement, while those of function and movement were normalized as gradual and progressive improvement over the next 2 months. The different functional test used (Barthel, MRC, VAS) showed that the mean values were significantly greater in Fast Track group when compared to the control. Conclusion The results of the study confirm that the application of the Fast Track protocol in orthopaedics after total knee replacement results in rapid post-surgery recovery. Level of evidence IV. Case series, low-quality cohort or case-control studies. PMID:29387645
Total knee arthroplasty in a patient with diastrophic dwarfism.
Crowley, Robin L; Haas, Richard E
2010-10-01
Diastrophic dwarfism is an autosomal recessive disease that predominantly occurs in the Finnish population (1 in 33,000) but has been known to occur worldwide. Affected patients present with multiple cartilaginous anomalies and early degeneration of weight-bearing joints. Once past infancy, life expectancy is favorable and patients may undergo multiple surgical procedures throughout their lifetime to repair .or replace affected joints. The characteristic short trunk of these patients in addition to scoliosis, cervical kyphosis, and involvement of articular cartilages can create unique ventilation and airway challenges for anesthesia providers involved in their care.
The Contribution of Reverse Shoulder Arthroplasty to Utilization of Primary Shoulder Arthroplasty
Jain, Nitin B.; Yamaguchi, Ken
2014-01-01
Background We assessed the contribution of reverse shoulder arthroplasty to overall utilization of primary shoulder arthroplasty, and present age and sex stratified national rates of shoulder arthroplasty. We also assessed contemporary complication rates, mortality, and indications for shoulder arthroplasty, as well as estimates and indications for revision arthroplasty. Methods We used the Nationwide Inpatient Samples for 2009–2011 to calculate estimates of shoulder arthroplasty and assessed trends using joinpoint regression. Results The cumulative estimated utilization of primary shoulder arthroplasty (total anatomical, hemi, and reverse) increased significantly from 52,397 procedures (95% CI=47,093–57,701) in 2009 to 67,184 cases (95% CI=60,638–73,731) in 2011. Reverse shoulder arthroplasty accounted for 42% of all primary shoulder arthroplasty procedures in 2011. The diagnosis of concomitant diagnosis of osteoarthritis and rotator cuff impairment was found in only 29.8% of reverse shoulder arthroplasty cases. The highest rate of reverse shoulder arthroplasty was in the 75–84 year female sub-group (77; 95% CI=67–87). Revision cases were 8.8% and 8.2% of all shoulder arthroplasties in 2009 and 2011, respectively, and 35% of revision cases were secondary to mechanical complications/loosening while 18% were due to dislocation. Conclusions The utilization of primary shoulder arthroplasty significantly increased in just a three year time span, with a major contribution from reverse shoulder arthroplasty in 2011. Indications appear to have expanded as a large percentage of patients did not have rotator cuff pathology. The burden from revision arthroplasties was also substantial and efforts to optimize outcomes and longevity of primary shoulder arthroplasty are needed. Level of evidence Epidemiology Study, Database Analysis PMID:25304043
Extensive Bone Reaction From Catastrophic Oxidized Zirconium Wear.
Cassar-Gheiti, Adrian J; Collins, Dennis; McCarthy, Tom
2016-01-01
The use of alternative bearing surfaces for total hip arthroplasty has become popular to minimize wear and increase longevity, especially in young patients. Oxidized zirconium (Oxinium; Smith & Nephew, Memphis, Tennessee) femoral heads were introduced in the past decade for use in total hip arthroplasty. The advantages of oxidized zirconium include less risk of fracture compared with traditional ceramic heads. This case report describes a patient with a history of bilateral avascular necrosis of the femoral head after chemotherapy for acute lymphoblastic leukemia. Nonoperative management of avascular necrosis failed, and the patient was treated with bilateral total hip arthroplasty. The patient was followed at regular intervals and had slow eccentric polyethylene wear during a 10-year period. After 10 years, the patient had accelerated wear, with femoral and acetabular bone changes as a result of Oxinium and ultrahigh-molecular-weight polyethylene wear during a 6-month period. This article highlights the unusual accelerated bone changes that occurred as a result of Oxinium wear particles. Copyright 2016, SLACK Incorporated.
Christ, Alexander B; Baral, Elexis; Koch, Chelsea; Shubin Stein, Beth E; Gonzalez Della Valle, Alejandro; Strickland, Sabrina M
2017-10-01
Patellofemoral arthroplasty (PFA) can be a successful, bone-sparing treatment for isolated patellofemoral arthritis. However, progression of tibio-femoral arthritis or incorrect indications may predispose patients to early conversion to total knee arthroplasty (TKA). The purpose of this study was to review the clinical cases and perform retrieval analysis of PFA conversions to TKA at our institution. Twenty one patellofemoral arthroplasties in 18 patients that were converted to TKA were identified through our implant retrieval registry. Sixteen implants were available for review by biomechanical engineers, who recorded surface markings, wear patterns, and integrity of fixation. Patient charts were reviewed and time to conversion, tourniquet time, conversion implant, additional surgeries, infections, and Kellgren & Lawrence grade of the tibio-femoral joint on pre-operative radiographs were recorded. PFAs converted to TKAs at our institution were implanted for an average of 2.7years. The most common reason for conversion was pain, but most patients had significant tibio-femoral arthritis, as indicated by an average Kellgren & Lawrence grade of 2.6. The average tourniquet time for these conversions was 67min. These patients underwent an average of one additional surgery per PFA converted, and the infection rate of these conversions was approximately 14%. Success of PFA depends upon correct patient selection rather than implant failure or wear. Conversion of PFA to TKA is technically similar to primary TKA, with similar post-operative pain relief and range of motion. However, infection rates and complications requiring further surgery are more consistent with results seen in revision TKA. IV. Copyright © 2017 Elsevier B.V. All rights reserved.
Vincent, John; Alshaygy, Ibrahim; Muir, Jeffrey M; Kuzyk, Paul
2018-01-01
While intraoperative navigation systems have been shown to improve outcomes in primary total hip arthroplasty (THA), their use in the context of revision has been largely overlooked. This case report presents the first documented use of an imageless navigation tool in the context of revision THA, and an unexpected benefit to the surgical procedure as a result. An 84-year-old female patient presented following five episodes of dislocation of the left hip and with pain in the left buttock, groin, and posterior aspect of her hip. Relevant surgical history included primary hip arthroplasty in 1999 and the first revision in 2014. Preoperative analysis revealed a constrained liner that had become disengaged and migrated inferiorly, lodging at the distal aspect of the femoral neck. Acetabular protrusion was also noted. The pre-operative plan included the replacement of the fragmented liner and likely of the acetabular cup due to hardware failure. Intraoperative assessment, however, revealed that the cup was in good condition and would be difficult to remove due to substantial bony ingrowth. With the assistance of imageless navigation, the orientation of the acetabular cup was determined and a new constrained liner was cemented into the preexisting acetabular component at an altered orientation, correcting anteversion by 7°. In revision hip arthroplasty cases, image-based navigation is limited by the presence of existing implants and corresponding metal artefact. This case demonstrates the successful use of an imageless navigation tool for revision surgery. Use of navigation led to the unexpected intraoperative discovery that the acetabular cup was in an acceptable state, and allowed the surgical team to correct the position of the cup using a constrained liner, thus preserving the cup. This significantly benefitted patient outcome, due to the risks associated with the removal of a firmly fixated acetabular cup. While more extensive research is required, this case demonstrates that imageless navigation may be an indispensable tool for revision surgery.
Reoperations following proximal interphalangeal joint nonconstrained arthroplasties.
Pritsch, Tamir; Rizzo, Marco
2011-09-01
To retrospectively analyze the reasons for reoperations following primary nonconstrained proximal interphalangeal (PIP) joint arthroplasty and review clinical outcomes in this group of patients with 1 or more reoperations. Between 2001 and 2009, 294 nonconstrained (203 pyrocarbon and 91 metal-plastic) PIP joint replacements were performed in our institution. A total of 76 fingers (59 patients) required reoperation (50 pyrocarbon and 26 metal-plastic). There were 40 women and 19 men with an average age of 51 years (range, 19-83 y). Primary diagnoses included osteoarthritis in 35, posttraumatic arthritis in 24, and inflammatory arthritis in 17 patients. There were 21 index, 27 middle, 18 ring, and 10 small fingers. The average number of reoperations per PIP joint was 1.6 (range, 1-4). A total of 45 joints had 1 reoperation, 19 had 2, 11 had 3, and 1 had 4. Extensor mechanism dysfunction was the most common reason for reoperation; it involved 51 of 76 fingers and was associated with Chamay or tendon-reflecting surgical approaches. Additional etiologies included component loosening in 17, collateral ligament failure in 10, and volar plate contracture in 8 cases. Inflammatory arthritis was associated with collateral ligament failure. Six fingers were eventually amputated, 9 had PIP joint arthrodeses, and 2 had resection arthroplasties. The arthrodesis and amputation rates correlated with the increased number of reoperations per finger. Clinically, most patients had no or mild pain at the most recent follow-up, and the PIP joint range-of-motion was not significantly different from preoperative values. Pain levels improved with longer follow-up. Reoperations following primary nonconstrained PIP joint arthroplasties are common. Extensor mechanism dysfunction was the most common reason for reoperation. The average reoperation rate was 1.6, and arthrodesis and amputation are associated with an increasing number of operations. Overall clinical outcomes demonstrated no significant change in range of motion, and most patients had mild or no pain. Copyright © 2011 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.
Femoral neck buttressing: a radiographic and histologic analysis.
Dixon, T; Benjamin, J; Lund, P; Graham, A; Krupinski, E
2000-10-01
To examine the incidence, radiographic and histologic findings of medial femoral neck buttressing in a consecutive group of patients undergoing total hip arthroplasty. Biomechanical parameters were evaluated on standard anteroposterior pelvic radiographs of 113 patients prior to hip replacement surgery. Demographic information on all patients was reviewed and histologic evaluation was performed on specimens obtained at the time of surgery. The incidence of medial femoral neck buttressing was found to be 50% in a consecutive series of patients undergoing total hip arthroplasty. The incidence was slightly higher in women (56% vs. 41%). Patients with buttressing had increased neck-shaft angles and smaller femoral neck diameters than were seen in patients without buttressing. Histologic evaluation demonstrated that the buttress resulted from deposition bone by the periosteum on the femoral neck in the absence of any evidence of femoral neck fracture. It would appear that femoral neck buttressing occurs in response to increased joint reactive forces seen at the hip being transmitted through the femoral neck. The increased joint reactive force can be related to the increased neck shaft angle seen in patients with buttressing.
Ashmore, Alexander M; Gozzard, Charles; Blewitt, Neil
2007-01-01
The Liverpool Elbow Score (LES) is a newly developed, validated elbow-specific score. It consists of a patient-answered questionnaire (PAQ) and a clinical assessment. The purpose of this study was to determine whether the PAQ portion of the LES could be used independently as a postal questionnaire for the assessment of outcome after total elbow arthroplasty and to correlate the LES and the Mayo Elbow Performance Score (MEPS). A series of 51 total elbow replacements were reviewed by postal questionnaire. Patients then attended the clinic for assessment by use of both the LES and the MEPS. There was an excellent response rate to the postal questionnaire (98%), and 44 elbows were available for clinical review. Good correlation was shown between the LES and the MEPS (Spearman correlation coefficient, 0.84; P < .001) and between the PAQ portion of the LES and the MEPS (Spearman correlation coefficient, 0.76; P < .001). We conclude that there is good correlation between the LES PAQ component and the MEPS, suggesting that outcome assessment is possible by postal questionnaire.
Economics of All-Polyethylene Versus Metal-Backed Tibial Prosthesis Designs.
Chambers, Monique C; El-Othmani, Mouhanad M; Sayeed, Zain; Anoushiravani, Afshin; Schnur, Anne-Kathrin; Mihalko, William M; Saleh, Khaled J
2016-05-01
With the large number of total knee arthroplasties being performed and expectations that these numbers will be on the rise over the coming decades, efforts to provide cost-efficient care are of greater interest. The preferred design of knee arthroplasty implants has changed over time, with the original all-polyethylene tibial (APT) design being replaced by metal-backed tibial (MBT) components, as well as more recent considerations of newer APT designs. Modern APT components have been shown to have similar or superior outcomes than MBT components. Despite their limitations, APT components can be used to reduce the economic burden to the provider, medical institution, and health care system as a whole. There is a paucity of evidence-based literature directly comparing the cost associated with APT and MBT components. The purpose of this report is to review the literature to assess the available data regarding direct and indirect costs of both designs so that orthopedic surgeons can account for economic differences in everyday practice. [Orthopedics. 2016; 39(3):S61-S66.]. Copyright 2016, SLACK Incorporated.
Wound closure in flexion versus extension following total knee arthroplasty: a systematic review.
Smith, Toby O; Davies, Leigh; Hing, Caroline B
2010-06-01
Optimising knee range of motion following total knee arthroplasty (TKA) is important for patient satisfaction, functional outcome and early rehabilitation to promote accelerated discharge. Historically, wound closure following TKA has been performed in extension. It has been suggested that knee position during wound closure may influence range of motion and clinical outcomes following TKA. The purpose of this study was to determine whether TKA wounds should be closed in flexion or extension. An electronic search of MEDLINE, EMBASE, CINAHL and AMED databases was made in addition to a review of unpublished material. All included papers were critically appraised using a modified PEDro (Physiotherapy Evidence Database) critical appraisal tool. Three papers were eligible, assessing 237 TKAs. On analysis, patients with TKA wounds closed in flexion had greater flexion range of motion and required less domiciliary physiotherapy compared to those with wounds closed in full extension. The specific degree of knee flexion used when closing total knee replacement wounds may be an important variable to clinical outcome. However, the present evidence-base is limited in both size and methodological quality.
Vanhegan, I S; Malik, A K; Jayakumar, P; Ul Islam, S; Haddad, F S
2012-05-01
Revision arthroplasty of the hip is expensive owing to the increased cost of pre-operative investigations, surgical implants and instrumentation, protracted hospital stay and drugs. We compared the costs of performing this surgery for aseptic loosening, dislocation, deep infection and peri-prosthetic fracture. Clinical, demographic and economic data were obtained for 305 consecutive revision total hip replacements in 286 patients performed at a tertiary referral centre between 1999 and 2008. The mean total costs for revision surgery in aseptic cases (n = 194) were £11 897 (sd 4629), for septic revision (n = 76) £21 937 (sd 10 965), for peri-prosthetic fracture (n = 24) £18 185 (sd 9124), and for dislocation (n = 11) £10 893 (sd 5476). Surgery for deep infection and peri-prosthetic fracture was associated with longer operating times, increased blood loss and an increase in complications compared to revisions for aseptic loosening. Total inpatient stay was also significantly longer on average (p < 0.001). Financial costs vary significantly by indication, which is not reflected in current National Health Service tariffs.
Prevalence of Total Hip and Knee Replacement in the United States.
Maradit Kremers, Hilal; Larson, Dirk R; Crowson, Cynthia S; Kremers, Walter K; Washington, Raynard E; Steiner, Claudia A; Jiranek, William A; Berry, Daniel J
2015-09-02
Descriptive epidemiology of total joint replacement procedures is limited to annual procedure volumes (incidence). The prevalence of the growing number of individuals living with a total hip or total knee replacement is currently unknown. Our objective was to estimate the prevalence of total hip and total knee replacement in the United States. Prevalence was estimated using the counting method by combining historical incidence data from the National Hospital Discharge Survey and the Healthcare Cost and Utilization Project (HCUP) State Inpatient Databases from 1969 to 2010 with general population census and mortality counts. We accounted for relative differences in mortality rates between those who have had total hip or knee replacement and the general population. The 2010 prevalence of total hip and total knee replacement in the total U.S. population was 0.83% and 1.52%, respectively. Prevalence was higher among women than among men and increased with age, reaching 5.26% for total hip replacement and 10.38% for total knee replacement at eighty years. These estimates corresponded to 2.5 million individuals (1.4 million women and 1.1 million men) with total hip replacement and 4.7 million individuals (3.0 million women and 1.7 million men) with total knee replacement in 2010. Secular trends indicated a substantial rise in prevalence over time and a shift to younger ages. Around 7 million Americans are living with a hip or knee replacement, and consequently, in most cases, are mobile, despite advanced arthritis. These numbers underscore the substantial public health impact of total hip and knee arthroplasties. Copyright © 2015 by The Journal of Bone and Joint Surgery, Incorporated.
Wang, Xiaonan; Malik, Aamer; Bartel, Donald L; Wright, Timothy M; Padgett, Douglas E
2016-08-01
The normal knee joint maintains stable motion during activities of daily living. After total knee arthroplasty (TKA), stability is achieved by the conformity of the bearing surfaces of the implant components, ligaments, and constraint structures incorporated in the implant design. The large, rectangular tibial post in constrained condylar knee (CCK) arthroplasty, often used in revision surgery, provides added stability, but increases susceptibility to polyethylene wear as it contacts the intercondylar box on the femoral component. We examined coronal plane stability to understand the relative contributions of the mechanisms that act to stabilize the CCK knee under varus-valgus loading, namely, load distribution between the medial and lateral condyles, contact of the tibial post with the femoral intercondylar box, and elongation of the collateral ligaments. A robot testing system was used to determine the joint stability in human cadaveric knees as described by the moment versus angular rotation behavior under varus-valgus moments at 0 deg, 30 deg, and 90 deg of flexion. The angular rotation of the CCK knee in response to the physiological moments was limited to ≤1.5 deg. The primary stabilizing mechanism was the redistribution of the contact force on the bearing surfaces. Contact between the tibial post and the femoral box provided a secondary stabilizing mechanism after lift-off of a condyle had occurred. Collateral ligaments provide limited stability because little ligament elongation occurred under such small angular rotations. Compressive loads applied across the knee joint, such as would occur with the application of muscle forces, enhanced the ability of the bearing surfaces to provide resisting internal varus-valgus moment and, thus, reduced the exposure of the tibial post to the external varus-valgus loads. Our results suggest that the CCK stability can be refined by considering both the geometry of the bearing surfaces and the contacting geometry between the tibial post and femoral box.
Kantak, Avadhoot P; Shah, Nirav N
2017-12-01
One of the local factors contributing to the formation of heterotopic ossification includes bone debris generated during the surgery. This risk can be partially nullified by use of saline wash. Our research aim was to ascertain if extensive intraoperative lavage can reduce the incidence and severity of heterotopic ossification in primary total hip arthroplasty. A retrospective case control radiological study of 145 patients (175 hip replacements). The control group received minimal intra-operative lavage (<1,000 mL); consisted of 90 primary hip replacements. The index group received extensive saline lavage (>3,000 mL), and included 85 primary hip replacements. Brooker classification was used to grade radiographs at one year for development of heterotopic ossification. Sixty-six patients in control group had heterotopic ossification, with six showing a significant grade (grade 3 or 4). Thirty-five patients in the index group had heterotopic ossification with no incidence of severe grade. Majority patients in the index group showed a predominantly grade 1 heterotopic ossification; 28 out of 35, as compared to 37 out of 66 in control group. There was a statistically significant difference in the incidence ( P <0.05) as well as severity of heterotopic ossification between the groups ( P <0.05). We conclude that use of extensive lavage during total hip replacement reduces the incidence as well as severity of heterotopic ossification.
Magosch, P; Habermeyer, P; Lichtenberg, S; Tauber, M; Gohlke, F; Mauch, F; Boehm, D; Loew, M; Zeifang, F; Pötzl, W
2017-12-01
Anatomic shoulder arthroplasty in osteoarthritis with biconcave glenoid wear results in decreased functional results and a higher rate of early glenoid loosening. The aim of the data analysis of the German shoulder arthroplasty register was to clarify whether reverse shoulder arthroplasty can provide better functional results and a lower complication rate than anatomic arthroplasty in osteoarthritis with biconcave glenoid wear. The analysis included 1052 completely documented primary implanted arthroplasties with a minimum follow-up of 2 years. In 119 cases, a B2-type glenoid was present. Out of these cases, 86 were treated with an anatomic shoulder arthroplasty, and in 33 cases a reverse shoulder arthroplasty was implanted. The mean follow-up was 47.6 months. The Constant score with its subcategories, as well as the active range of movement improved significantly after anatomic and after reverse shoulder arthroplasty. We observed no difference in functional results between both types of arthroplasty; however, reverse arthroplasty showed a significant higher revision rate (21.2%) (3% glenoid loosening, 6% prosthetic instability) than anatomic shoulder arthroplasty (12.8%) (11.6% glenoid loosening, 1.2% prosthetic instability), whereas anatomic shoulder arthroplasty showed a higher rate of glenoid loosening. Functional and radiographic results of both types of arthroplasty are comparable with the results reported in the literature, although our analysis represents results from an implant registry (data pertaining to medical care quality).
Li, Wei; Zhou, Yi-Xin; Wu, Jian; Xu, Hui; Ji, Song-Jie
2009-02-15
To evaluate the bone refilling in the interface between the trabecular metal (TM) acetabular shell and the bone surface according to consecutive X film measuring after surgery. From July 2006 to July 2007, 35 patients (40 hips) accepted total hip replacement using trabecular metal monoblock acetabular cup system (TM). The cup was made of a ellipse shaped press fit Tantalum shell and high cross-linked PE liner (Longevity) with 28 mm inner diameter. The patients demography was: 16 male (20 hips), 19 female (20 hips), 5 bilateral hip replacements, age from 41 - 71 (mean 53), including 18 avascular necrosis hips, 16 osteoarthritis hips (including those secondary to a dysplasia hip), 4 avascular necrosis hips after femoral neck fracture, 2 Ankylosis Spondylitis. All the 40 total hip replacements used posterior approach, using hemispherical acetabular reamer and 2 mm press fit of final metal shell without screw fixation. The consecutive X film was taken at the end time of surgery and 2, 6, 12, 24 weeks, and 12 months. The clinical results was evaluate according to Harris scoring system, and the standard pelvis AP X film was measured at the interface between metal shell and the acetabular bone surface, witch was divided into five regions (A, B, C, D, E). Totally 32 patients (37 hips) were followed with average 8.7 months (7 - 12 months). The Harris before surgery was 50.5 (32 - 85), promoted to 91.0 (72 - 100), including 29 excellent, 6 good, 2 fair, and the total excellent and good rate was 94.6%. Complications include 4 patients leg length discrepancy from 1 - 2 cm, 3 patients moderate thigh pain and released after conservative therapy. No infection and dislocation was found. Twenty-one patients (23 hips) were found lucent line at the bone-metal interface from 1 - 5 mm, most common in B region and BC boundary than C, D, and CD boundary. All the patients followed was found the lucent line disappeared and refilled with bone at X film 24 weeks after surgery, however, no patients was found osteolysis and cup migration. The trabecular metal has strong capacity of bone conductive and bone inducement.
Gagnier, Joel J; Mullins, Megan; Huang, Hsiaomin; Marinac-Dabic, Danica; Ghambaryan, Anna; Eloff, Benjamin; Mirza, Faisal; Bayona, Manuel
2017-05-01
While clinical research on total knee arthroplasty (TKA) outcomes is prevalent in the literature, studies often have poor methodological and reporting quality. A high-quality patient-reported outcome instrument is reliable, valid, and responsive. Many studies evaluate these properties, but none have done so with a systematic and accepted method. The objectives of this study were to identify patient-reported outcome measures (PROMs) for TKA, and to critically appraise, compare, and summarize their psychometric properties using accepted methods. MEDLINE, EMBASE, SCOPUS, Web of Science, PsycINFO, and SPORTDiscus were systematically searched for articles with the following inclusion criteria: publication before December 2014, English language, non-generic PRO, and evaluation in the TKA population. Methodological quality and evidence of psychometric properties were assessed with the COnsensus-based standards for the selection of health Status Measurement INstruments (COSMIN) checklist and criteria for psychometric evidence proposed by the COSMIN group and Terwee et al. One-hundred fifteen studies on 32 PROMs were included in this review. Only the Work, Osteoarthritis or joint-Replacement Questionnaire, the Oxford Knee Score, and the Western Ontario and McMaster Universities Arthritis Index had 4 or more properties with positive evidence. Most TKA PROMs have limited evidence for their psychometric properties. Although not all the properties were studied, the Work, Osteoarthritis or joint-Replacement Questionnaire, with the highest overall ratings, could be a useful PROM for evaluating patients undergoing TKA. The methods and reporting of this literature can improve by following accepted guidelines. Published by Elsevier Inc.
Lowe, Catherine J Minns; Davies, Linda; Sackley, Catherine M; Barker, Karen L
2015-09-01
Existing review required updating. To evaluate the effectiveness of physiotherapy exercise after discharge from hospital on function, walking, range of motion, quality of life and muscle strength, for patients following elective primary total hip arthroplasty for osteoarthritis. Systematic review from January 2007 to November 2013. AMED, CINAHL, EMBASE, MEDLINE, Kingsfund Database, and PEDro. Cochrane CENTRAL, BioMed Central (BMC), The Department of Health National Research Register and Clinical Trials.gov register. Searches were overseen by a librarian. Authors were contacted for missing information. No language restrictions were applied. Trials comparing physiotherapy exercise vs usual/standard care, or comparing two types of relevant exercise physiotherapy, following discharge from hospital after elective primary total hip replacement for osteoarthritis were reviewed. Functional activities of daily living, walking, quality of life, muscle strength and joint range of motion. Quality and risk of bias for studies were evaluated. Data were extracted and meta-analyses considered. 11 trials are included in the review. Trial quality was mixed. Newly included studies were assessed as having lower risk of bias than previous studies. Narrative review indicates that physiotherapy exercise after discharge following total hip replacement may potentially benefit patients in terms of function, walking and muscle strengthening. The overall quality and quantity of trials, and their diversity, prevented meta-analyses. Disappointingly, insufficient evidence still prevents the effectiveness of physiotherapy exercise following discharge to be determined for this patient group. High quality, adequately powered, trials with long term follow up are required. Copyright © 2015 Chartered Society of Physiotherapy. Published by Elsevier Ltd. All rights reserved.
[Patellar bone deficiency in revision total knee arthroplasty].
Kloiber, J; Goldenitsch, E; Ritschl, P
2016-05-01
Patellar bone deficiency in revision total knee arthroplasty (TKA) determines the surgical procedure. Different reconstructive and ablative techniques, dependent on the remaining bone stock, are described. The primary patella implant can be retained in up to 50 % of revision situations. Reasons for replacement are aseptic and septic loosening, implant failure, expanding osteolysis, maltracking of the patella and "metal-backed" prosthesis. The aim of the reconstruction is the stable fixation and proper tracking of the implant by restoring the extensor mechanism. Dependent on the extent of bone loss and the availability of a patellar rim, the following surgical procedures are recommended. When the remaining bone thickness is 10 mm or more: implantation of a polyethylene "onlay-type" patella; when it is between 6-9 mm and there is an intact patellar rim: reconstruction with a biconvex "inlay-type" patella implant, where the biconvex shape replaces the bone defect partially. When there is deficient bone stock (less than 6 mm) or no cortical patellar rim then augmenting procedures with autologous spongiosa and procedures such as "impaction bone grafting", "trabecular metal" prosthesis, where the trabecular part of the implant serves as the base for the cemented polyethylene button, "gull-wing" osteotomy, which is an adapting and configuring technique of osteotomy; and in exceptional cases patelloplasty or patellectomy are used. Regarding the importance of the patellar component in biomechanics of the joint and function of the extensor mechanism, the reconstruction of the patella should be the primary aim. Patelloplasty or patellectomy should be avoided.
Clarke-Jenssen, John; Westberg, Marianne; Røise, Olav; Storeggen, Stein Arne Øvre; Bere, Tone; Silberg, Ingunn; Madsen, Jan Erik
2017-11-01
Post traumatic arthritis and avascular necrosis of the femoral head are common complications after operatively treated acetabular fractures. This may cause severe disabilities for the patient, necessitating a total hip arthroplasty. Even though an arthroplasty may provide good symptomatic relief, the long-term results are more uncertain and no consensus exists according to preferred prosthetic designs. With this cohort study, we aimed to investigate the medium to long term arthroplasty survival and clinical results of total hip arthroplasty after operatively treated acetabular fractures. We included 52 patients treated with a secondary total hip arthroplasty at a median of 2.4 (0.1-14.1) years after an operatively treated acetabular fracture. The median age was 54 (11-82) years. Cemented arthroplasty was used for 33 patients, 10 patients had an uncemented arthroplasty and 9 patients received a hybrid arthroplasty. Average follow up was 8.0 (SD 5.0) years. Ten-year revision free arthroplasty survival was 79%. Uncemented arthroplasties had a significantly worse 10-year survival of 57%. Arthroplasties performed at a centre without a pelvic fracture service also had a significantly worse 10-years survival of 51%. Cox regression showed similar results with an 8-fold increase in risk of revision for both uncemented arthroplasties and operations performed at a non-pelvic trauma centre. Total hip arthroplasty secondary to an operatively treated acetabular fracture provides good symptomatic relief. These patients are, however, complex cases and are probably best treated at specialist centres with both pelvic trauma surgeons and arthroplasty surgeons proficient in complex revisions present. Copyright © 2017 Elsevier Ltd. All rights reserved.
Metal-on-Metal Total Hip Resurfacing Arthroplasty: An Evidence-Based Analysis.
2006-01-01
The objective of this review was to assess the safety and effectiveness of metal on metal (MOM) hip resurfacing arthroplasty for young patients compared with that of total hip replacement (THR) in the same population. Total hip replacement has proved to be very effective for late middle-aged and elderly patients with severe degenerative diseases of the hips. As indications for THR began to include younger patients and those with a more active life style, the longevity of the implant became a concern. Evidence suggests that these patients experience relatively higher rates of early implant failure and the need for revision. The Swedish hip registry, for example, has demonstrated a survival rate in excess of 80% at 20 years for those aged over 65 years, whereas this figure was 33% by 16 years in those aged under 55 years. Hip resurfacing arthroplasty is a bone-conserving alternative to THR that restores normal joint biomechanics and load transfer. The technique has been used around the world for more than 10 years, specifically in the United Kingdom and other European countries. Metal-on-metal hip resurfacing arthroplasty is an alternative procedure to conventional THR in younger patients. Hip resurfacing arthroplasty is less invasive than THR and addresses the problem of preserving femoral bone stock at the initial operation. This means that future hip revisions are possible with THR if the initial MOM arthroplasty becomes less effective with time in these younger patients. The procedure involves the removal and replacement of the surface of the femoral head with a hollow metal hemisphere, which fits into a metal acetabular cup. Hip resurfacing arthroplasty is a technically more demanding procedure than is conventional THR. In hip resurfacing, the femoral head is retained, which makes it much more difficult to access the acetabular cup. However, hip resurfacing arthroplasty has several advantages over a conventional THR with a small (28 mm) ball. First, the large femoral head reduces the chance of dislocation, so that rates of dislocation are less than those with conventional THR. Second, the range of motion with hip resurfacing arthroplasty is higher than that achieved with conventional THR. A variety of MOM hip resurfacing implants are used in clinical practice. Six MOM hip resurfacing implants have been issued licences in Canada. A search of electronic bibliographies (OVID Medline, Medline In-Process and Other Non-Indexed Citations, Embase, Cochrane CENTRAL and DSR, INAHTA) was undertaken to identify evidence published from Jan 1, 1997 to October 27, 2005. The search was limited to English-language articles and human studies. The literature search yielded 245 citations. Of these, 11 met inclusion criteria (9 for effectiveness, 2 for safety). The result of the only reported randomized controlled trial on MOM hip resurfacing arthroplasty could not be included in this assessment, because it used a cemented acetabular component, whereas in the new generation of implants, a cementless acetabular component is used. After omitting this publication, only case series remained. HEALTH OUTCOMES: The Harris hip score and SF-12 are 2 measures commonly used to report health outcomes in MOM hip resurfacing arthroplasty studies. Other scales used are the Oxford hip score and the University of California Los Angeles hip score. The case series showed that the mean revision rate of MOM hip resurfacing arthroplasty is 1.5% and the incidence of femoral neck fracture is 0.67%. Across all studies, 2 cases of osteonecrosis were reported. Four studies reported improvement in Harris hip scores. However, only 1 study reported a statistically significant improvement. Three studies reported improvement in SF-12 scores, of which 2 reported a significant improvement. One study reported significant improvement in UCLA hip score. Two studies reported postoperative Oxford hip scores, but no preoperative values were reported. None of the reviewed studies reported procedure-related deaths. Four studies reported implant survival rates ranging from 94.4% to 99.7% for a follow-up period of 2.8 to 3.5 years. Three studies reported on the range of motion. One reported improvement in all motions including flexion, extension, abduction-adduction, and rotation, and another reported improvement in flexion. Yet another reported improvement in range of motion for flexion abduction-adduction and rotation arc. However, the author reported a decrease in the range of motion in the arc of flexion in patients with Brooker class III or IV heterotopic bone (all patients were men). SAFETY OF METAL-ON-METAL HIP RESURFACING ARTHROPLASTY: There is a concern about metal wear debris and its systemic distribution throughout the body. Detectable metal concentrations in the serum and urine of patients with metal hip implants have been described as early as the 1970s, and this issue is still controversial after 35 years. Several studies have reported high concentration of cobalt and chromium in serum and/or urine of the patients with metal hip implants. Potential toxicological effects of the elevated metal ions have heightened concerns about safety of MOM bearings. This is of particular concern in young and active patients in whom life expectancy after implantation is long. Since 1997, 15 studies, including 1 randomized clinical trial, have reported high levels of metal ions after THR with metal implants. Some of these studies have reported higher metal levels in patients with loose implants. Because patients who receive a MOM hip arthroplasty are shown to be exposed to high concentrations of metallic ions, the Medical Advisory Secretariat searched the literature for reports of adverse biological effects of cobalt and chromium. Cobalt and chromium make up the major part of the metal articulations; therefore, they are a focus of concern. To date, only one study has examined the incidence of cancer after MOM and polyethylene on metal total hip arthroplasties. The results were compared to that of general population in Finland. The mean duration of follow-up for MOM arthroplasty was 15.7 years; for polyethylene arthroplasty, it was 12.5 years. The standardized incidence ratio for all cancers in the MOM group was 0.95 (95% CI, 0.79-1.13). In the polyethylene on metal group it was 0.76 (95% CI, 0.68-0.86). The combined standardized incidence ratio for lymphoma and leukemia in the patients who had MOM THR was 1.59 (95% CI, 0.82-2.77). It was 0.59 (95% CI, 0.29-1.05) for the patients who had polyethylene on metal THR. Patients with MOM THR had a significantly higher risk of leukemia. All patients who had leukemia were aged over than 60 years. EPIDEMIOLOGICAL STUDIES OF MYOCARDIOPATHY OF BEER DRINKERS: An unusual type of myocardiopathy, characterized by pericardial effusion, elevated hemoglobin concentrations, and congestive heart failure, occurred as an epidemic affecting 48 habitual beer drinkers in Quebec City between 1965 and 1966. This epidemic was directly related the consumption of a popular beer containing cobalt sulfate. The epidemic appeared 1 month after cobalt sulfate was added to the specific brewery, and no further cases were seen a month after this specific chemical was no longer used in making this beer. A beer of the same name is made in Montreal, and the only difference at that time was that the Quebec brand of beer contained about 10 times more cobalt sulphate. Cobalt has been added to some Canadian beers since 1965 to improve the stability of the foam but it has been added in larger breweries only to draught beer. However, in small breweries, such as those in Quebec City, separate batches were not brewed for bottle and draught beer; therefore, cobalt was added to all of the beer processed in this brewery. In March 1966, a committee was appointed under the chairmanship of the Deputy Minister of Health for Quebec that included members of the department of forensic medicine of Quebec's Ministry of Justice, epidemiologists, members of Food and Drug Directorate of Ottawa, toxicologists, biomedical researchers, pathologists, and members of provincial police. Epidemiological studies were carried out by the Provincial Ministry of Health and the Quebec City Health Department. The association between the development of myocardiopathy and the consumption of the particular brand of beer was proven. The mortality rate of this epidemic was 46.1% and those who survived were desperately ill, and recovered only after a struggle for their lives. Similar cases were seen in Omaha (Nebraska). The epidemic started after a cobalt additive was used in 1 of the beers marketed in Nebraska. Sixty-four patients with the clinical diagnosis of alcoholic myocardiopathy were seen during an 18-month period (1964-1965). Thirty of these patients died. The first patient became ill within 1 month after cobalt was added to the beer, and the last patient was seen within 1 month of withdrawal of cobalt. A similar epidemic occurred in Minneapolis, Minnesota. Between 1964 and 1967, 42 patients with acute heart failure were admitted to a hospital in Minneapolis, Minnesota. Twenty of these patients were drinking 6 to 30 bottles per day of a particular brand of beer exclusively. The other 14 patients also drank the same brand of beer, but not exclusively. The mortality rate from the acute illness was 18%, but late deaths accounted for a total mortality rate of 43%. Examination of the tissue from these patients revealed markedly abnormal changes in myofibrils (heart muscles), mitochondria, and sarcoplasmic reticulum. In Belgium, a similar epidemic was reported in 1966, in which, cobalt was used in some Belgian beers. (ABSTRACT TRUNCATED)
Uncemented glenoid component in total shoulder arthroplasty. Survivorship and outcomes.
Martin, Scott David; Zurakowski, David; Thornhill, Thomas S
2005-06-01
Glenoid component loosening continues to be a major factor affecting the long-term survivorship of total shoulder replacements. Radiolucent lines, cement fracture, migration, and loosening requiring revision are common problems with cemented glenoid components. The purpose of this study was to evaluate the results of total shoulder arthroplasty with an uncemented glenoid component and to identify predictors of glenoid component failure. One hundred and forty-seven consecutive total shoulder arthroplasties were performed in 132 patients (mean age, 63.3 years) with use of an uncemented glenoid component fixed with screws between 1988 and 1996. One hundred and forty shoulders in 124 patients were available for follow-up at an average of 7.5 years. One shoulder in which the arthroplasty had failed at 2.4 years and for which the duration of follow-up was four years was also included for completeness. The preoperative diagnoses included osteoarthritis in seventy-two shoulders and rheumatoid arthritis in fifty-five. Radiolucency was noted around the glenoid component and/or screws in fifty-three of the 140 shoulders. The mean modified ASES (American Shoulder and Elbow Surgeons) score (and standard deviation) improved from 15.6 +/- 11.8 points preoperatively to 75.8 +/- 17.5 points at the time of follow-up. Eighty-five shoulders were not painful, forty-two were slightly or mildly painful, ten were moderately painful, and three were severely painful. Fifteen (11%) of the glenoid components failed clinically, and ten of them also had radiographic signs of failure. Eleven other shoulders had radiographic signs of failure but no symptoms at the time of writing. Three factors had a significant independent association with clinical failure: male gender (p = 0.02), pain (p < 0.01), and radiolucency adjacent to the flat tray (p < 0.001). In addition, the annual risk of implant revision was nearly seven times higher for patients with radiographic signs of failure. Clinical survivorship was 95% at five years and 85% at ten years. The failure rates of the total shoulder arthroplasties in this study were higher than those in previously reported studies of cemented polyethylene components with similar durations of follow-up. Screw breakage and excessive polyethylene wear were common problems that may lead to additional failures of these uncemented glenoid components in the future.
Konopka, Joseph F.; Gomoll, Andreas H.; Thornhill, Thomas S.; Katz, Jeffrey N.; Losina, Elena
2015-01-01
Background: Surgical options for the management of medial compartment osteoarthritis of the varus knee include high tibial osteotomy, unicompartmental knee arthroplasty, and total knee arthroplasty. We sought to determine the cost-effectiveness of high tibial osteotomy and unicompartmental knee arthroplasty as alternatives to total knee arthroplasty for patients fifty to sixty years of age. Methods: We built a probabilistic state-transition computer model with health states defined by pain, postoperative complications, and subsequent surgical procedures. We estimated transition probabilities from published literature. Costs were determined from Medicare reimbursement schedules. Health outcomes were measured in quality-adjusted life-years (QALYs). We conducted analyses over patients’ lifetimes from the societal perspective, with health and cost outcomes discounted by 3% annually. We used probabilistic sensitivity analyses to account for uncertainty in data inputs. Results: The estimated discounted QALYs were 14.62, 14.63, and 14.64 for high tibial osteotomy, unicompartmental knee arthroplasty, and total knee arthroplasty, respectively. Discounted total direct medical costs were $20,436 for high tibial osteotomy, $24,637 for unicompartmental knee arthroplasty, and $24,761 for total knee arthroplasty (in 2012 U.S. dollars). The incremental cost-effectiveness ratio (ICER) was $231,900 per QALY for total knee arthroplasty and $420,100 per QALY for unicompartmental knee arthroplasty. Probabilistic sensitivity analyses showed that, at a willingness-to-pay (WTP) threshold of $50,000 per QALY, high tibial osteotomy was cost-effective 57% of the time; total knee arthroplasty, 24%; and unicompartmental knee arthroplasty, 19%. At a WTP threshold of $100,000 per QALY, high tibial osteotomy was cost-effective 43% of time; total knee arthroplasty, 31%; and unicompartmental knee arthroplasty, 26%. Conclusions: In fifty to sixty-year-old patients with medial unicompartmental knee osteoarthritis, high tibial osteotomy is an attractive option compared with unicompartmental knee arthroplasty and total knee arthroplasty. This finding supports greater utilization of high tibial osteotomy for these patients. The cost-effectiveness of high tibial osteotomy and of unicompartmental knee arthroplasty depend on rates of conversion to total knee arthroplasty and the clinical outcomes of the conversions. Level of Evidence: Economic Level II. See Instructions for Authors for a complete description of levels of evidence. PMID:25995491
van Steenbergen, Liza N; Spooren, Anneke; van Rooden, Stephanie M; van Oosterhout, Frank J; Morrenhof, Jan W; Nelissen, Rob G H H
2015-01-01
Background and purpose A complete and correct national arthroplasty register is indispensable for the quality of arthroplasty outcome studies. We evaluated the coverage, completeness, and validity of the Dutch Arthroplasty Register (LROI) for hip and knee arthroplasty. Patients and methods The LROI is a nationwide population-based registry with information on joint arthroplasties in the Netherlands. Completeness of entered procedures was validated in 2 ways: (1) by comparison with the number of reimbursements for arthroplasty surgeries (Vektis database), and (2) by comparison with data from hospital information systems (HISs). The validity was examined by conducting checks on missing or incorrectly coded values in the LROI. Results The LROI contains over 300,000 hip and knee arthroplasties performed since 2007. Coverage of all Dutch hospitals (n = 100) was reached in 2012. Completeness of registered procedures was 98% for hip arthroplasty and 96% for knee arthroplasty in 2012, based on Vektis data. Based on comparison with data from the HIS, completeness of registered procedures was 97% for primary total hip arthroplasty and 96% for primary knee arthroplasty in 2013. Completeness of revision arthroplasty was 88% for hips and 90% for knees in 2013. The proportion of missing or incorrectly coded values of variables was generally less than 0.5%, except for encrypted personal identity numbers (17% of which were missing) and ASA scores (10% of which were missing). Interpretation The LROI now contains over 300,000 hip and knee arthroplasty procedures, with coverage of all hospitals. It has a good level of completeness (i.e. more than 95% for primary hip and knee arthroplasty procedures in 2012 and 2013) and the database has high validity. PMID:25758646
Tsukeoka, Tadashi; Tsuneizumi, Yoshikazu
2016-03-01
Although sagittal tibial alignment in total knee arthroplasty (TKA) is important, no landmarks exist to achieve a reproducible slope. The purpose of this study was to evaluate the clinical usefulness of the distance from the guide rod to the skin surface for the tibial slope in TKA. Computer simulation studies were performed on 100 consecutive knees scheduled for TKA. The angle between the line connecting the most anterior point of the predicted tibial cut surface and the skin surface 20 cm distal to the predicted cut surface (Line S) and the mechanical axis (MA) of the tibia in the sagittal plane was measured. The mean (±SD) absolute angle difference between the Line S and the MA was 0.9°±0.7°. The Line S was almost parallel to the MA in the sagittal plane (95% and 99% within two degrees and three degrees of deviation from MA, respectively). The guide rod orientation is a surrogate for the tibial cut slope because the targeted posterior slope is usually built into the cutting block and ensuring the rod is parallel to the MA in the sagittal plane is recommended. Therefore the distance between the skin surface and the rod can be a useful guide for the tibial slope. II. Copyright © 2015 Elsevier B.V. All rights reserved.
Chronic Quadriceps Tendon Rupture After Total Knee Arthroplasty Augmented With Synthetic Mesh.
Ormaza, Amaia; Moreta, Jesús; Mosquera, Javier; de Ugarte, Oskar Sáez; Mozos, José Luis Martinez-de Los
2017-01-01
Tear of the quadriceps tendon after revision or primary total knee arthroplasty is a rare complication, but when it occurs, this injury has serious functional consequences. In complete tears, the outcome of direct repair is unpredictable, and several authors recommend that the suture should be reinforced. Several techniques have been described, including the use of autografts, allografts, and synthetic mesh. The goal of this study was to assess the outcomes of a reconstruction technique augmented with synthetic mesh. A retrospective study was performed involving 3 patients who had chronic partial quadriceps tendon tear after total knee revision. In 2 cases, proximal quadriceps release was performed. When conservative management failed, surgical reconstruction with suture reinforced with synthetic mesh was attempted. The knee was immobilized in full extension for 6 weeks after the surgical procedure. A minimum follow-up of 12 months was required to assess results. All reconstructions showed clinical success at a mean follow-up of 19 months. Mean Knee Society Score improved from 55.7 to 87.3, with average postoperative extensor lag of 3.3° (range, 0°-10°). The mean visual analog scale pain score was 2.3 (range, 0-4). No complications were reported. Synthetic mesh has previously been shown to be an effective treatment for patellar tendon repairs after total knee replacement, but there have been few articles on quadriceps rupture. Surgical reconstruction with synthetic mesh is a viable option that provides good functional outcomes in chronic quadriceps tendon rupture after total knee arthroplasty. [Orthopedics. 2017; 40(1):38-42.]. Copyright 2016, SLACK Incorporated.
Apostolopoulos, Alexandros; Lallos, Stergios; Mastrokalos, Dimitrios; Michos, Ioannis; Darras, Nikolaos; Tzomaki, Magda; Efstathopoulos, Nikolaos
2011-01-01
The objective of this study was to capture and analyze the kinetics and kinematics and determine the functional performance of the osteoarthritic knee after a posterior cruciate ligament (PCL) retaining total knee arthroplasty. Kinematic and kinetic gait analysis of level walking was performed in 20 subjects (12 female and 8 male) with knee ostoarthritis. These patients were free of any neurological diseases that could affect their normal gait. Mean age was 69.6 ± 6.6 years; mean height was 157.6 cm ± 7.6 cm; and mean weight was 77.2 ± 12.1 kg. Full body gait analyses were performed using the BIOKIN 3D motion analysis system before and 9 months after total knee arthroplasty procedures. Single-step ascending kinetic analyses and plantar pressure distribution analyses were also performed for all subjects. International Knee Society Scores (IKSSs) were also assessed pre- and postoperatively. Significant increases were noted postoperatively in average cadence (preoperative mean = 99.26, postoperative mean = 110.5; p < 0.004), step length (preoperative mean = 0.49, postoperative mean = 0.54; p < 0.01) , and walking velocity (preoperative mean = 0.78, preoperatively, postoperative mean = 0.99; p < 0.001). Decreases in stance duration percentage and knee adduction moment were also reported postoperatively. All patients showed a significant improvement of knee kinetics and kinematics after a PCL retaining total knee arthroplasty. Significant differences were found in the cadence, step length, stride length, and walk velocity postoperatively. IKSSs also significantly improved. Further research is warranted to determine the clinical relevance of these findings.
Perlas, Anahi; Chan, Vincent W S; Beattie, Scott
2016-10-01
This propensity score-matched cohort study evaluates the effect of anesthetic technique on a 30-day mortality after total hip or knee arthroplasty. All patients who had hip or knee arthroplasty between January 1, 2003, and December 31, 2014, were evaluated. The principal exposure was spinal versus general anesthesia. The primary outcome was 30-day mortality. Secondary outcomes were (1) perioperative myocardial infarction; (2) a composite of major adverse cardiac events that includes cardiac arrest, myocardial infarction, or newly diagnosed arrhythmia; (3) pulmonary embolism; (4) major blood loss; (5) hospital length of stay; and (6) operating room procedure time. A propensity score-matched-pair analysis was performed using a nonparsimonious logistic regression model of regional anesthetic use. We identified 10,868 patients, of whom 8,553 had spinal anesthesia and 2,315 had general anesthesia. Ninety-two percent (n = 2,135) of the patients who had general anesthesia were matched to similar patients who did not have general anesthesia. In the matched cohort, the 30-day mortality rate was 0.19% (n = 4) in the spinal anesthesia group and 0.8% (n = 17) in the general anesthesia group (risk ratio, 0.42; 95% CI, 0.21 to 0.83; P = 0.0045). Spinal anesthesia was also associated with a shorter hospital length of stay (5.7 vs. 6.6 days; P < 0.001). The results of this observational, propensity score-matched cohort study suggest a strong association between spinal anesthesia and lower 30-day mortality, as well as a shorter hospital length of stay, after elective joint replacement surgery.
Surgical waste audit of 5 total knee arthroplasties.
Stall, Nathan M; Kagoma, Yoan M; Bondy, Jennifer N; Naudie, Douglas
2013-04-01
Operating rooms (ORs) are estimated to generate up to one-third of hospital waste. At the London Health Sciences Centre, prosthetics and implants represent 17% of the institution's ecological footprint. To investigate waste production associated with total knee arthroplasties (TKAs), we performed a surgical waste audit to gauge the environmental impact of this procedure and generate strategies to improve waste management. We conducted a waste audit of 5 primary TKAs performed by a single surgeon in February 2010. Waste was categorized into 6 streams: regular solid waste, recyclable plastics, biohazard waste, laundered linens, sharps and blue sterile wrap. Volume and weight of each stream was quantified. We used Canadian Joint Replacement Registry data (2008-2009) to estimate annual weight and volume totals of waste from all TKAs performed in Canada. The average surgical waste (excluding laundered linens) per TKA was 13.3 kg, of which 8.6 kg (64.5%) was normal solid waste, 2.5 kg (19.2%) was biohazard waste, 1.6 kg (12.1%) was blue sterile wrap, 0.3 kg (2.2%) was recyclables and 0.3 kg (2.2%) was sharps. Plastic wrappers, disposable surgical linens and personal protective equipment contributed considerably to total waste. We estimated that landfill waste from all 47 429 TKAs performed in Canada in 2008-2009 was 407 889 kg by weight and 15 272 m3 by volume. Total knee arthroplasties produce substantial amounts of surgical waste. Environmentally friendly surgical products and waste management strategies may allow ORs to reduce the negative impacts of waste production without compromising patient care. Level IV, case series.
Effect of tranexamic acid administration on bleeding in primary total hip arthroplasty.
Fernández-Cortiñas, A B; Quintáns-Vázquez, J M; Gómez-Suárez, F; Murillo, O Simón; Sánchez-López, B R; Pena-Gracía, J M
To study the efficacy of tranexamic acid to decrease perioperative bleeding in patients who have undergone a total hip arthroplasty operation and to evaluate drug safety. Observational, prospective, controlled and randomized study on the efficacy of tranexamic acid as a method to reduce bleeding in primary hip replacement surgery. We included 134 patients operated during 2014 in our centre, who were divided into 2 groups according to whether or not they had received tranexamic acid. The main study variables were haemoglobin and haematocrit levels, the amount of blood collected from the post-operative drain in the first 12, 24 and 48hours and transfusion requirements. Post-operative haemoglobin and haematocrit levels were statistically higher (P<.001) in the group with treatment. During the first 48hours bleeding values from the group that did not receive TAX were higher compared to patients treated with tranexamic acid. Statistically significant differences (P=.001) were found as to the need for transfusion according to group, more transfusions were performed in the cohort that had not received tranexamic acid: 25.37% compared to 4.48% for the group with tranexamic acid. No adverse events related to administration of tranexamic acid were recorded. Administration of tranexamic acid has proved to be an effective and safe method to reduce peri-operative bleeding in patients who underwent total hip arthroplasty and avoids allogenic blood transfusion. Therefore, tranexamic acid treatment could entail a financial saving for the healthcare system and expose the patient to less risk. Copyright © 2017 SECOT. Publicado por Elsevier España, S.L.U. All rights reserved.
[Incidence of hip and knee prosthetic infections in a specialized center of Mexico City].
Franco-Cendejas, Rafael; Contreras-Córdova, Erika Lizbeth; Mondragón-Eguiluz, Jaime Arturo; Vanegas-Rodríguez, Edgar Samuel; Ilizaliturri-Sánchez, Víctor Manuel; Galindo-Fraga, Arturo
Hip and knee prosthetic replacements have proven to be the most appropriate treatment in the joints that do not benefit from medical or arthroscopic interventions; however, infections are the most feared complication. It is recommended that the incidence of infection should not exceed 2%. This was an observational, prospective, longitudinal and observational study conducted in patients fitted with a prosthetic joint from August 2011 to July 2012. Patients were followed up pre and post-surgery for one year to identify a prosthetic infection, diagnosed using international parameters. We calculated the incidence of prosthetic infection, as well as the incidence density. A total of 339 patients (179 hip and 160 knee) were included. Variations in the time of pre-operative antibiotics' administration were observed. Six prosthetic infections were identified with an incidence rate of 1.79/339 arthroplasties, 2.2/179 hip procedures, and 1.25/160 knee arthroplasties. An incidence density of 0.02/year for hip arthroplasties and 0.11/year for knee procedures was identified. There were 4 infections of hip and 2 of knee. Five infections were acute and one chronic. The isolated microorganisms were E. faecalis, S. epidermidis (2), S. mitis, S. aureus and P. stomatis. The incidence of prosthetic joint infection in the first year of follow-up at our centre is within the recommended parameters. Surgical techniques and organizational practices influence the results. Copyright © 2016 Academia Mexicana de Cirugía A.C. Publicado por Masson Doyma México S.A. All rights reserved.
Outcomes of a Joint Replacement Surgical Home Model Clinical Pathway
Chaurasia, Avinash; Garson, Leslie; Kain, Zeev L.; Schwarzkopf, Ran
2014-01-01
Optimizing perioperative care to provide maximum benefit at minimum cost may be best achieved using a perioperative clinical pathway (PCP). Using our joint replacement surgical home (JSH) model PCP, we examined length of stay (LOS) following total joint arthroplasty (TJA) to evaluate patient care optimization. We reviewed a spectrum of clinical measurements in 190 consecutive patients who underwent TJA. Patients who had surgery earlier in the week and who were earlier cases of the day had a significantly lower LOS than patients whose cases started both later in the week and later in the day. Patients discharged home had significantly lower LOS than those discharged to a secondary care facility. Patients who received regional versus general anesthesia had a significantly lower LOS. Scheduling patients discharged to home and who will likely receive regional anesthesia for the earliest morning slot and earlier in the week may help decrease overall LOS. PMID:25025045
van der Linde, M J; Tonino, A J
1997-12-01
In 600 consecutive uncemented total hip replacements, 2 surgical approaches were used: the direct lateral Hardinge approach in supine position (group I: 241 cases) or in a lateral position (group II: 280 cases) and the anterolateral Watson-Jones approach in supine position (group III: 79 cases). 5 patients had clinically evident peripheral nerve injuries confirmed with EMG: none in group I, 1 lesion of the nervus ischiadicus and nervus femoralis in group II and 4 nervus femoralis lesions in group III, of which 1 was combined with an obturator nerve injury. The nerve injuries were evaluated with EMG. All 4 nervus femoralis lesions recovered spontaneously, but the one patients in group II had a persistent palsy of the peroneal nerve. The anatomical basis for the higher prevalence of nervus femoralis lesions in the anterolateral Watson-Jones approach is described.
Bundled Payments in Total Joint Replacement: Keeping Our Care Affordable and High in Quality.
McLawhorn, Alexander S; Buller, Leonard T
2017-09-01
The purpose of this review was to evaluate the literature regarding bundle payment reimbursement models for total joint arthroplasty (TJA). From an economic standpoint, TJA are cost-effective, but they represent a substantial expense to the Centers for Medicare & Medicaid Services (CMS). Historically, fee-for-service payment models resulted in highly variable cost and quality. CMS introduced Bundled Payments for Care Improvement (BPCI) in 2012 and subsequently the Comprehensive Care for Joint Replacement (CJR) reimbursement model in 2016 to improve the value of TJA from the perspectives of both CMS and patients, by improving quality via cost control. Early results of bundled payments are promising, but preserving access to care for patients with high comorbidity burdens and those requiring more complex care is a lingering concern. Hospitals, regardless of current participation in bundled payments, should develop care pathways for TJA to maximize efficiency and patient safety.
Wittig-Wells, Deborah; Higgins, Melinda; Davis, Erica; Johnson, Ifeya; Louis, Latalya; Mason, Olga; Samms-McPherson, Jacqueline; Sims, Sandra; Jacob, Ani
2015-01-01
Patient education for the use and administration of aspirin (ASA) as an anticoagulant may be deficient. To pilot a knowledge assessment tool regarding the use of aspirin (ASA) as an anticoagulant and to evaluate the impact of a focused approach for discharge teaching. One-group pretest-posttest pilot study. Convenience sample of patients hospitalized for total knee and total hip arthroplasty. Researcher developed ASA quiz. Focused education on aspirin as an anticoagulant. There was a statistically significant improvement in knowledge (Wilcoxon rank sum test Z = 3.880, p < .001).
Health Care Reform: Impact on Total Joint Replacement.
Chambers, Monique C; El-Othmani, Mouhanad M; Saleh, Khaled J
2016-10-01
The US health care system has been fragmented for more than 40 years; this model created a need for modification. Sociopoliticomedical system-related factors led to the Affordable Care Act (ACA) and a restructuring of health care provision/delivery. The ACA increases access to high-quality "affordable care" under cost-effective measures. This article provides a comprehensive review of health reform and the motivating factors that drive policy to empower arthroplasty providers to effectively advocate for the field of orthopedics as a whole, and the patients served. Copyright © 2016 Elsevier Inc. All rights reserved.
The effect of bearing type on the outcome of total hip arthroplasty.
Peters, Rinne M; Van Steenbergen, Liza N; Stevens, Martin; Rijk, Paul C; Bulstra, Sjoerd K; Zijlstra, Wierd P
2018-04-01
Background and purpose - Alternative bearing surfaces such as ceramics and highly crosslinked polyethylene (HXLPE) were developed in order to further improve implant performance of total hip arthroplasties (THAs). Whether these alternative bearing surfaces result in increased longevity is subject to debate. Patients and methods - Using the Dutch Arthroplasty Register (LROI), we identified all patients with a primary, non-metal-on-metal THA implanted in the Netherlands in the period 2007-2016 (n = 209,912). Cumulative incidence of revision was calculated to determine differences in survivorship of THAs according to bearing type: metal-on-polyethylene (MoPE), metal-on-HXLPE (MoHXLPE), ceramic-on-polyethylene (CoPE), ceramic-on-HXLPE (CoHXLPE), ceramic-on-ceramic (CoC), and oxidized-zirconium-on-(HXL)polyethylene (Ox(HXL)PE). Multivariable Cox proportional hazard regression ratios (HRs) were used for comparisons. Results - After adjustment for confounders, CoHXLPE, CoC, and Ox(HXL)PE resulted in a statistically significantly lower risk of revision compared with MoPE after 9 years follow-up (HR =0.8-0.9 respectively, compared with HR =1.0). For small (22-28 mm) femoral head THAs, lower revision rates were found for CoPE and CoHXLPE (HR =0.9). In the 36 mm femoral head subgroup, CoC-bearing THAs had a lower HR compared with MoHXLPE (HR =0.7 versus 1.0). Crude revision rates in young patients (< 60 years) for CoHXLPE, CoC, and Ox(HXL)PE (HR =0.7) were lower than MoPE (HR =1.0). However, after adjustment for case mix and confounders these differences were not statistically significant. Interpretation - We found a mid-term lower risk of revision for CoHXLPE, CoC, and Ox(HXL)PE bearings compared with traditional MoPE-bearing surfaces.
Buttaro, Martin A; Zanotti, Gerardo; Comba, Fernando M; Piccaluga, Francisco
2017-02-01
Delta ceramics may be the bearing of choice for younger and active patients due to its improved toughness and wear characteristics, provided there is no risk of fracture. However, ceramic fracture is the most serious complication related to this type of bearing. Although millions of Delta ceramics have been implanted worldwide, short to midterm results have been scarcely reported in the literature. The purpose of this study was to report the complication rate at short to midterm follow-up associated with the bearing surface used in a series of primary total hip arthroplasties with Delta ceramic-on-ceramic bearings performed in a single institution. A total of 939 cases (880 patients) undergoing primary total hip arthroplasty with fourth-generation Delta ceramic-on-ceramic bearings were retrospectively reviewed. They were followed for an average of 5.3 years (2-10 years). One hip experienced a liner fracture, 2 cups presented early loosening due to friction between the acetabular screw and the backside of the liner, one femoral ball head had a fracture; one case of squeaking was reported, which is impending revision. Considering revision or impending revision in relationship with the bearing surface as the end point, the mean survival rate was 99.3% (confidence interval 95%, 98.3%-99.7%) at 2-10 years. This study showed a low rate of ceramic fracture compared with others; however, it was much higher than the complication rate presented by the manufacturers. The complications observed were directly related to technical errors that surgeons should avoid when using this type of surface. Copyright © 2016 Elsevier Inc. All rights reserved.
Inter and intra-system size variability of reverse shoulder arthroplasty polyethylene inserts
Teeter, Matthew G.; Dawson, Matthew T.; Athwal, George S.
2016-01-01
Background: As the incidence of reverse shoulder arthroplasty (RSA) increases, so will the revision burden. At times, the revision surgeon may be faced with a well-fixed component on one side of the joint and revision implants from a different manufacturer. The ability to use glenoid and humeral implants from different manufacturers could simplify the revision procedure. This study hypothesized that across a range of RSA systems, some implants would demonstrate high size compatibility and others would demonstrate low compatibility. Materials and Methods: Six polyethylene inserts each from eight reverse total shoulder arthroplasty systems were examined (48 total inserts). All inserts were scanned using a laboratory micro-computed tomography scanner at 50 μm isotropic voxel spacing, and their surface geometries were reconstructed. The different implant geometries were co-registered, and the three-dimensional (3D) variability between the articular surfaces of the different implant systems was measured. Intrasystem manufacturing variability was also determined by measuring the 3D variability of inserts from the same system. Results: The intersystem polyethylene articular surface deviations between same-size systems were not significantly different (P = 0.61) and were a mean maximum of 60 ± 16 μm (range: 30-80 μm). Intrasystem manufacturing variability was equivalent between all but two models, averaging 49 ± 17 μm (range: 23-99 μm). Discussion: Differences in articular geometry between same-size inserts from different systems were on the same scale as intrasystem manufacturing variability, suggesting that different implant systems of the same nominal diameter could potentially be used interchangeably in revision or extenuating circumstances. Conclusion: The results of this study suggest that surgeons can theoretically interchange same-sized implant components from the different RSA systems tested when conducting revisions. PMID:26980984
Cement-in-cement acetabular revision with a constrained tripolar component.
Leonidou, Andreas; Pagkalos, Joseph; Luscombe, Jonathan
2012-02-17
Dislocation of a total hip replacement (THR) is common following total hip arthroplasty (THA). When nonoperative management fails to maintain reduction, revision surgery is considered. The use of constrained acetabular liners has been extensively described. Complete removal of the old cement mantle during revision THA can be challenging and is associated with significant complications. Cement-in-cement revision is an established technique. However, the available clinical and experimental studies focus on femoral stem revision. The purpose of this study was to present a case of cement-in-cement acetabular revision with a constrained component for recurrent dislocations and to investigate the current best evidence for this technique. This article describes the case of a 74-year-old woman who underwent revision of a Charnley THR for recurrent low-energy dislocations. A tripolar constrained acetabular component was cemented over the primary cement mantle following removal of the original liner by reaming, roughening the surface, and thoroughly irrigating and drying the primary cement. Clinical and radiological results were good, with the Oxford Hip Score improving from 11 preoperatively to 24 at 6 months postoperatively. The good short-term results of this case and the current clinical and biomechanical data encourage the use of the cement-in-cement technique for acetabular revision. Careful irrigation, drying, and roughening of the primary surface are necessary. Copyright 2012, SLACK Incorporated.
Bitter, T; Khan, I; Marriott, T; Schreurs, B W; Verdonschot, N; Janssen, D
2016-03-01
The modular taper junction in total hip replacements has been implicated as a possible source of wear. The finite-element (FE) method can be used to study the wear potential at the taper junction. For such simulations it is important to implement representative contact parameters, in order to achieve accurate results. One of the main parameters in FE simulations is the coefficient of friction. However, in current literature, there is quite a wide spread in coefficient of friction values (0.15 - 0.8), which has a significant effect on the outcome of the FE simulations. Therefore, to obtain more accurate results, one should use a coefficient of friction that is determined for the specific material couple being analyzed. In this study, the static coefficient of friction was determined for two types of titanium-on-titanium stem-adaptor couples, using actual cut-outs of the final implants, to ensure that the coefficient of friction was determined consistently for the actual implant material and surface finish characteristics. Two types of tapers were examined, Biomet type-1 and 12/14, where type-1 has a polished surface finish and the 12/14 is a microgrooved system. We found static coefficients of friction of 0.19 and 0.29 for the 12/14 and type-1 stem-adaptor couples, respectively.
Arnholt, Christina M; MacDonald, Daniel W; Malkani, Arthur L; Klein, Gregg R; Rimnac, Clare M; Kurtz, Steven M; Kocagoz, Sevi B; Gilbert, Jeremy L
2016-12-01
Metal debris and ion release has raised concerns in joint arthroplasty. The purpose of this study was to characterize the sources of metallic ions and particulate debris released from long-term (in vivo >15 years) total knee arthroplasty femoral components. A total of 52 CoCr femoral condyles were identified as having been implanted for more than 15 years. The femoral components were examined for incidence of 5 types of damage (metal-on-metal wear due to historical polyethylene insert failure, mechanically assisted crevice corrosion at taper interfaces, cement interface corrosion, third-body abrasive wear, and inflammatory cell-induced corrosion [ICIC]). Third-body abrasive wear was evaluated using the Hood method for polyethylene components and a similar method quantifying surface damage of the femoral condyle was used. The total area damaged by ICIC was quantified using digital photogrammetry. Surface damage associated with corrosion and/or CoCr debris release was identified in 51 (98%) CoCr femoral components. Five types of damage were identified: 98% of femoral components exhibited third-body abrasive wear (mostly observed as scratching, n = 51/52), 29% of femoral components exhibited ICIC damage (n = 15/52), 41% exhibited cement interface damage (n = 11/27), 17% exhibited metal-on-metal wear after wear-through of the polyethylene insert (n = 9/52), and 50% of the modular femoral components exhibited mechanically assisted crevice corrosion taper damage (n = 2/4). The total ICIC-damaged area was an average of 0.11 ± 0.12 mm 2 (range: 0.01-0.46 mm 2 ). Although implant damage in total knee arthroplasty is typically reported with regard to the polyethylene insert, the results of this study demonstrate that abrasive and corrosive damage occurs on the CoCr femoral condyle in vivo. Copyright © 2016 Elsevier Inc. All rights reserved.
Prevalence of neurologic lesions after total shoulder arthroplasty.
Lädermann, A; Lübbeke, A; Mélis, B; Stern, R; Christofilopoulos, P; Bacle, G; Walch, G
2011-07-20
Clinically evident neurologic injury of the involved limb after total shoulder arthroplasty is not uncommon, but the subclinical prevalence is unknown. The purposes of this prospective study were to determine the subclinical prevalence of neurologic lesions after reverse shoulder arthroplasty and anatomic shoulder arthroplasty, and to evaluate the correlation of neurologic injury to postoperative lengthening of the arm. All patients undergoing either a reverse or an anatomic shoulder arthroplasty were included during the period studied. This study focused on the clinical, radiographic, and preoperative and postoperative electromyographic evaluation, with measurement of arm lengthening in patients who had reverse shoulder arthroplasty according to a previously validated protocol. Between November 2007 and February 2009, forty-one patients (forty-two shoulders) underwent reverse shoulder arthroplasty (nineteen shoulders) or anatomic primary shoulder arthroplasty (twenty-three shoulders). The two groups were similar with respect to sex distribution, preoperative neurologic lesions, and Constant score. Electromyography performed at a mean of 3.6 weeks postoperatively in the reverse shoulder arthroplasty group showed subclinical electromyographic changes in nine shoulders, involving mainly the axillary nerve; eight resolved in less than six months. In the anatomic shoulder arthroplasty group, a brachial plexus lesion was evident in one shoulder. The prevalence of acute postoperative nerve injury was significantly more frequent in the reverse shoulder arthroplasty group (p = 0.002), with a 10.9 times higher risk (95% confidence interval, 1.5 to 78.5). Mean lengthening (and standard deviation) of the arm after reverse shoulder arthroplasty was 2.7 ± 1.8 cm (range, 0 to 5.9 cm) compared with the normal, contralateral side. The occurrence of peripheral neurologic lesions following reverse shoulder arthroplasty is relatively common, but usually transient. Arm lengthening with a reverse shoulder arthroplasty may be responsible for these nerve injuries.
A history of reverse total shoulder arthroplasty.
Flatow, Evan L; Harrison, Alicia K
2011-09-01
Management of the cuff-deficient arthritic shoulder has long been challenging. Early unconstrained shoulder arthroplasty systems were associated with high complication and implant failure rates. The evolution toward the modern reverse shoulder arthroplasty includes many variables of constrained shoulder arthroplasty designs. This review explores the development of reverse shoulder arthroplasty, specifically describing (1) the evolution of reverse shoulder arthroplasty designs, (2) the biomechanical variations in the evolution of this arthroplasty, and (3) the current issues relevant to reverse shoulder arthroplasty today. Using a PubMed search, the literature was explored for articles addressing reverse shoulder arthroplasty, focusing on those papers with historical context. Results of the early designs were apparently poor, although they were not subjected to rigorous clinical research and usually reported only in secondary literature. We identified a trend of glenoid component failure in the early reverse designs. This trend was recognized and reported by authors as the reverse shoulder evolved. Authors reported greater pain relief and better function in reverse shoulder arthroplasty with the fundamental change of Grammont's design (moving the center of rotation medially and distally). However, current reports suggest lingering concerns and challenges with today's designs. The history of reverse shoulder arthroplasty involves the designs of many forward-thinking surgeons. Many of these highly constrained systems failed, although more recent designs have demonstrated improved longevity and implant performance. Reverse shoulder arthroplasty requires ongoing study, with challenges and controversies remaining around present-day designs.
Functional outcomes after shoulder resection: the patient's perspective.
Stevens, Nicole M; Kim, H Mike; Armstrong, April D
2015-09-01
Resection arthroplasty is a salvage procedure used for the treatment of deep-seated infections after total shoulder arthroplasty, hemiarthroplasty, and reverse total shoulder arthroplasty. Previous studies have reported a 50% to 66% rate of pain relief after resection arthroplasty but with significant functional limitations. Our study aimed to qualify the perspective of the patients on their limitations and satisfaction with resection arthroplasty. A retrospective record review of resection arthroplasties performed between September 2003 and December 2012 yielded 14 patients, and 7 completed the survey. The patients completed surveys with the focus on the "patient perspective." Functional scores, including American Shoulder and Elbow Surgeons, Simple Shoulder Test, Disabilities of the Arm, Shoulder, and Hand (DASH), DASH work, and DASH sports, were determined. Pain reduction and functional outcomes were similar to past reports of resection arthroplasty. Five of the 7 patients (71%) reported satisfaction with their resection arthroplasty, and 6 of the 7 patients (86%) would undergo the procedure again if given the choice. Five of the 7 patients (71%) were able to most of activities of daily living. Patients in our study were generally satisfied with their resection arthroplasty. Resection arthroplasty is a reasonable option for treatment of deep-seated periprosthetic infections or for patients with multiple previous failed procedures for total shoulder arthroplasty, hemiarthroplasty. and reverse shoulder arthroplasty. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Identification of hip surface arthroplasty failures with TcSC/TcmDP radionuclide imaging
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thomas, B.J.; Amstutz, H.C.; Mai, L.L.
1982-07-01
The roentgenographic identification of femoral component loosening after hip surface arthroplasty is often impossible because the metallic femoral component obscures the bone-cement interface. The use of combined technetium sulfur colloid and technetium methylene diphosphonate radionuclide imaging has been especially useful in the diagnosis of loosening. In 40 patients, follow-up combined TcSC and TcmDP scans at an average of three, nine, and 27 months postoperation revealed significant differences in the isotope uptakes in patients who had loose prostheses compared with those without complications. Scans were evaluated by first dividing them into eight anatomical regions and then rating the uptake in eachmore » region or 'zone' on a five-point scale. Results were compared using the Student's t-test and differences were noted between normal controls and patients who had femoral component loosening. Combining both TcSC and TcmDP studies increased the statistical significance obtained when comparing patients who had complications to those in the control group.« less
2004-01-01
The Medical Advisory Secretariat undertook a review of the evidence on the effectiveness and cost-effectiveness of computer assisted hip and knee arthroplasty. The two computer assisted arthroplasty systems that are the topics of this review are (1) navigation and (2) robotic-assisted hip and knee arthroplasty. Computer-assisted arthroplasty consists of navigation and robotic systems. Surgical navigation is a visualization system that provides positional information about surgical tools or implants relative to a target bone on a computer display. Most of the navigation-assisted arthroplasty devices that are the subject of this review are licensed by Health Canada. Robotic systems are active robots that mill bone according to information from a computer-assisted navigation system. The robotic-assisted arthroplasty devices that are the subject of this review are not currently licensed by Health Canada. The Cochrane and International Network of Agencies for Health Technology Assessment databases did not identify any health technology assessments on navigation or robotic-assisted hip or knee arthroplasty. The MEDLINE and EMBASE databases were searched for articles published between January 1, 1996 and November 30, 2003. This search produced 367 studies, of which 9 met the inclusion criteria. NAVIGATION-ASSISTED ARTHROPLASTY: Five studies were identified that examined navigation-assisted arthroplasty.A Level 1 evidence study from Germany found a statistically significant difference in alignment and angular deviation between navigation-assisted and free-hand total knee arthroplasty in favour of navigation-assisted surgery. However, the endpoints in this study were short-term. To date, the long-term effects (need for revision, implant longevity, pain, functional performance) are unknown.(1)A Level 2 evidence short-term study found that navigation-assisted total knee arthroplasty was significantly better than a non-navigated procedure for one of five postoperative measured angles.(2)A Level 2 evidence short-term study found no statistically significant difference in the variation of the abduction angle between navigation-assisted and conventional total hip arthroplasty.(3)Level 3 evidence observational studies of navigation-assisted total knee arthroplasty and unicompartmental knee arthroplasty have been conducted. Two studies reported that "the follow-up of the navigated prostheses is currently too short to know if clinical outcome or survival rates are improved. Longer follow-up is required to determine the respective advantages and disadvantages of both techniques."(4;5) ROBOTIC-ASSISTED ARTHROPLASTY: Four studies were identified that examined robotic-assisted arthroplasty.A Level 1 evidence study revealed that there was no statistically significant difference between functional hip scores at 24 months post implantation between patients who underwent robotic-assisted primary hip arthroplasty and those that were treated with manual implantation.(6)Robotic-assisted arthroplasty had advantages in terms of preoperative planning and the accuracy of the intraoperative procedure.(6)Patients who underwent robotic-assisted hip arthroplasty had a higher dislocation rate and more revisions.(6)Robotic-assisted arthroplasty may prove effective with certain prostheses (e.g., anatomic) because their use may result in less muscle detachment.(6)An observational study (Level 3 evidence) found that the incidence of severe embolic events during hip relocation was lower with robotic arthroplasty than with manual surgery.(7)An observational study (Level 3 evidence) found that there was no significant difference in gait analyses of patients who underwent robotic-assisted total hip arthroplasty using robotic surgery compared to patients who were treated with conventional cementless total hip arthroplasty.(8)An observational study (Level 3 evidence) compared outcomes of total knee arthroplasty between patients undergoing robotic surgery and patients who were historical controls. Brief, qualitative results suggested that there was much broader variation of angles after manual total knee arthroplasty compared to the robotic technique and that there was no difference in knee functional scores or implant position at the 3 and 6 month follow-up.(9).
Computer-Assisted Hip and Knee Arthroplasty. Navigation and Active Robotic Systems
2004-01-01
Executive Summary Objective The Medical Advisory Secretariat undertook a review of the evidence on the effectiveness and cost-effectiveness of computer assisted hip and knee arthroplasty. The two computer assisted arthroplasty systems that are the topics of this review are (1) navigation and (2) robotic-assisted hip and knee arthroplasty. The Technology Computer-assisted arthroplasty consists of navigation and robotic systems. Surgical navigation is a visualization system that provides positional information about surgical tools or implants relative to a target bone on a computer display. Most of the navigation-assisted arthroplasty devices that are the subject of this review are licensed by Health Canada. Robotic systems are active robots that mill bone according to information from a computer-assisted navigation system. The robotic-assisted arthroplasty devices that are the subject of this review are not currently licensed by Health Canada. Review Strategy The Cochrane and International Network of Agencies for Health Technology Assessment databases did not identify any health technology assessments on navigation or robotic-assisted hip or knee arthroplasty. The MEDLINE and EMBASE databases were searched for articles published between January 1, 1996 and November 30, 2003. This search produced 367 studies, of which 9 met the inclusion criteria. Summary of Findings Navigation-Assisted Arthroplasty Five studies were identified that examined navigation-assisted arthroplasty. A Level 1 evidence study from Germany found a statistically significant difference in alignment and angular deviation between navigation-assisted and free-hand total knee arthroplasty in favour of navigation-assisted surgery. However, the endpoints in this study were short-term. To date, the long-term effects (need for revision, implant longevity, pain, functional performance) are unknown.(1) A Level 2 evidence short-term study found that navigation-assisted total knee arthroplasty was significantly better than a non-navigated procedure for one of five postoperative measured angles.(2) A Level 2 evidence short-term study found no statistically significant difference in the variation of the abduction angle between navigation-assisted and conventional total hip arthroplasty.(3) Level 3 evidence observational studies of navigation-assisted total knee arthroplasty and unicompartmental knee arthroplasty have been conducted. Two studies reported that “the follow-up of the navigated prostheses is currently too short to know if clinical outcome or survival rates are improved. Longer follow-up is required to determine the respective advantages and disadvantages of both techniques.”(4;5) Robotic-Assisted Arthroplasty Four studies were identified that examined robotic-assisted arthroplasty. A Level 1 evidence study revealed that there was no statistically significant difference between functional hip scores at 24 months post implantation between patients who underwent robotic-assisted primary hip arthroplasty and those that were treated with manual implantation.(6) Robotic-assisted arthroplasty had advantages in terms of preoperative planning and the accuracy of the intraoperative procedure.(6) Patients who underwent robotic-assisted hip arthroplasty had a higher dislocation rate and more revisions.(6) Robotic-assisted arthroplasty may prove effective with certain prostheses (e.g., anatomic) because their use may result in less muscle detachment.(6) An observational study (Level 3 evidence) found that the incidence of severe embolic events during hip relocation was lower with robotic arthroplasty than with manual surgery.(7) An observational study (Level 3 evidence) found that there was no significant difference in gait analyses of patients who underwent robotic-assisted total hip arthroplasty using robotic surgery compared to patients who were treated with conventional cementless total hip arthroplasty.(8) An observational study (Level 3 evidence) compared outcomes of total knee arthroplasty between patients undergoing robotic surgery and patients who were historical controls. Brief, qualitative results suggested that there was much broader variation of angles after manual total knee arthroplasty compared to the robotic technique and that there was no difference in knee functional scores or implant position at the 3 and 6 month follow-up.(9) PMID:23074452
[Patellofemoral arthroplasty].
Cotic, M; Forkel, P; Imhoff, A B
2017-02-01
Isolated resurfacing of the trochlea using an inlay prosthesis without changing the complex kinematics of the patellofemoral joint. Symptomatic, isolated patellofemoral osteoarthritis or isolated osteochondral lesions, failed conservative and cartilage regeneration procedures. No or concurrently corrected ligament instability, tibiofemoral and patellofemoral malalignment. Symptomatic patellofemoral osteoarthritis, inflammatory joint disease, chondrocalcinosis, chronic pain syndromes, active infections or knee ankylosis. Following a medial arthrotomy, coronal and sagittal curvatures of the trochlea are measured. Based on these measurements, corresponding surface reamers create an implant bed by removing damaged cartilage of the trochlea. A central fixation screw is placed to the desired depth and the inlay prosthesis is tapped carefully onto it. Final placement of the prosthesis is targeted slightly recessed to the surrounding joint surface. Free passive range of motion exercises of the knee joint are recommended starting on postoperative day 1. Depending on symptoms (e.g., pain and joint effusion), partial weight-bearing of 20 kg is allowed during postoperative weeks 1 and 2, which is increased by 20 kg/week thereafter. In a prospective study of 29 patients (mean age: 42 years) treated with inlay arthroplasty, 2‑year follow-up results showed significant improvements (p < 0.05) in WOMAC, IKDC and VAS (pain) scores when compared to baseline. Compared to onlay PF arthroplasty modern inlay prosthetic placement showed a better preservation of the tibiofemoral joint without progression of tibiofemoral degeneration. This may be due to possible avoidance of patellofemoral overstuffing using a more physiological placement of the inlay prosthesis.
Alta, Tjarco D W; Veeger, DirkJan H E J; de Toledo, Joelly M; Janssen, Thomas W J; Willems, W Jaap
2014-11-01
Range of motion after total shoulder arthroplasty is better than after reverse shoulder arthroplasty, however with similar clinical outcome. It is unclear if this difference can only be found in the different range of motion or also in the force generating capacity. (1) are isokinetically produced joint torques of reverse shoulder arthroplasty comparable to those of total shoulder arthroplasty? (2) Does this force-generating capacity correlate with functional outcome? Eighteen reverse shoulder arthroplasty patients (71years (SD 9years)) (21 shoulders, follow-up of 21months (SD 10months)) were recruited, 12 total shoulder arthroplasty patients (69years (SD 9years)) (14 shoulders, follow-up of 35months (SD 11months)). Pre- and post-operative Constant-Murley scores were obtained; two isokinetic protocols (ab-/adduction and ex-/internal rotations) at 60°/s were performed. Twelve of 18 reverse shoulder arthroplasty patients generated enough speed to perform the test (13 shoulders). Mean ab-/adduction torques are 16.3Nm (SD 5.6Nm) and 20.4Nm (SD 11.8Nm). All total shoulder arthroplasty patients generated enough speed (14 shoulders). Mean ab-/adduction torques are 32.1Nm (SD 13.3Nm) and 43.1Nm (SD 21.5Nm). Only 8 reverse shoulder arthroplasty patients (9 shoulders) could perform ex-/internal rotation tasks and all total shoulder arthroplasty patients. Mean ex-/internal rotation torques are 9.3Nm (SD 4.7Nm) and 9.2Nm (SD 2.1Nm) for reverse shoulder arthroplasty, and 17.9Nm (SD 7.7Nm) and 23.5Nm (SD 10.6Nm) for total shoulder arthroplasty. Significant correlations between sub-scores: activity, mobility and strength and external rotation torques for reverse shoulder arthroplasty. Moderate to strong correlation for sub-scores: strength in relation to abduction, adduction and internal rotation torques for total shoulder arthroplasty. Shoulders with a total shoulder arthroplasty are stronger. This can be explained by the absence of rotator cuff muscles and (probably) medialized center of rotation in reverse shoulder arthroplasty. The strong correlation between external rotation torques and post-operative Constant-Murley sub-scores demonstrates that external rotation is essential for good clinical functioning in reverse shoulder arthroplasty. Copyright © 2014 Elsevier Ltd. All rights reserved.
Patterned CoCrMo and Al2 O3 surfaces for reduced free wear debris in artificial joint arthroplasty.
Tarabolsi, Mohamad; Klassen, Thomas; Mantwill, Frank; Gärtner, Frank; Siegel, Frank; Schulz, Arndt-Peter
2013-12-01
Surface wear of corresponding tribological pairings is still a major problem in the application of artificial joint surgery. This study aims at developing wear reduced surfaces to utilize them in total joint arthroplasty. Using a pico-second laser, samples of medical CoCrMo metal alloy and Al2 O3 ceramic were patterned by laser material removal. The subsequent tribological investigations employed a ring-on-disc method. The results showed that those samples with modified surfaces show less mass or volume loss than those with a regular, smooth surface. Using calf serum as lubricating medium, the volume loss of the structured CoCrMo samples was eight times lower than that of regular samples. By structuring Al2 O3 surfaces, the wear volume could be reduced by 4.5 times. The results demonstrate that defined surface channels or pits enable the local sedimentation of wear debris. Thus, the amount of free debris could be reduced. Fewer abrasives in the lubricated so-called three-body-wear between the contact surfaces should result in less surface damage. Apart from direct influences on the wear behavior, less amounts of free debris of artificial joints should also be beneficial for avoiding undesired reactions with the surrounding soft tissues. The results from this study are very promising. Future investigations should involve the use of simulators meeting the natural conditions in the joint and in vivo studies with living organisms. Copyright © 2013 Wiley Periodicals, Inc., a Wiley Company.
Influence of Surface Coating on Metal Ion Release: Evaluation in Patients With Metal Allergy.
Thomas, Peter; Weik, Thomas; Roider, Gabriele; Summer, Burkhard; Thomsen, Marc
2016-05-01
Nickel, chromium, and cobalt in stainless steel and Cobalt-chrome-molybdenum (CoCrMo) alloys may induce allergy. The objectives of this study were to evaluate surface coating regarding ion release, patch test reactivity, and arthroplasty performance. Materials and methods included patch test in 31 patients with metal allergy and 30 patients with no allergy to stainless steel and CoCrMo disks that are uncoated or coated by titanium nitride/zirconium nitride (TiN/ZrN). Assessment include atomic absorption spectrometry of released nickel, cobalt, and chromium from the disks after exposure to distilled water, artificial sweat and culture medium. Results showed that both coatings reduced the nickel and chromium release from stainless steel and CoCrMo disks and mostly the cobalt release from the disks (maximally 11.755 µg/cm(2)/5 d to 1.624 by Ti-N and to 0.442 by ZrN). Six of the 31 patients with metal allergy reacted to uncoated disks, but none reacted to the coated disks. The current authors report on exemplary patients with metal allergy who had symptom relief by revision with surface-coated arthroplasty. The authors concluded that the surface coating may prevent cutaneous and peri-implant allergic reactions. [Orthopedics. 2016; 39(3):S24-S30.]. Copyright 2016, SLACK Incorporated.
Moore, Andrew J; Blom, Ashley W; Whitehouse, Michael R; Gooberman-Hill, Rachael
2017-04-12
Approximately 88,000 primary hip replacements are performed in England and Wales each year. Around 1% go on to develop deep prosthetic joint infection. Between one-stage and two-stage revision arthroplasty best treatment options remain unclear. Our aims were to characterise consultant orthopaedic surgeons' decisions about performing either one-stage or two-stage revision surgery for patients with deep prosthetic infection (PJI) after hip arthroplasty, and to identify whether a randomised trial comparing one-stage with two-stage revision would be feasible. Semi-structured interviews were conducted with 12 consultant surgeons who perform revision surgery for PJI after hip arthroplasty at 5 high-volume National Health Service (NHS) orthopaedic departments in England and Wales. Surgeons were interviewed before the development of a multicentre randomised controlled trial. Data were analysed using a thematic approach. There is no single standardised surgical intervention for the treatment of PJI. Surgeons balance multiple factors when choosing a surgical strategy which include multiple patient-related factors, their own knowledge and expertise, available infrastructure and the infecting organism. Surgeons questioned whether it was appropriate that the two-stage revision remained the best treatment, and some surgeons' willingness to consider more one-stage revisions had increased over recent years and were influenced by growing evidence showing equivalence between surgical techniques, and local observations of successful one-stage revisions. Custom-made articulating spacers was a practice that enabled uncertainty to be managed in the absence of definitive evidence about the superiority of one surgical technique over the other. Surgeons highlighted the need for research evidence to inform practice and thought that a randomised trial to compare treatments was needed. Most surgeons thought that patients who they treated would be eligible for trial participation in instances where there was uncertainty about the best treatment option. Surgeons highlighted the need for evidence to support their choice of revision. Some surgeons' willingness to consider one-stage revision for infection had increased over time, largely influenced by evidence of successful one-stage revisions. Custom-made articulating spacers also enabled surgeons to manage uncertainty about the superiority of surgical techniques. Surgeons thought that a prospective randomised controlled trial comparing one-stage with two-stage joint replacement is needed and that randomisation would be feasible.
Rossler, Tomas; Mandat, Dusan; Gallo, Jiri; Hrabovsky, Miroslav; Pochmon, Michal; Havranek, Vitezslav
2009-07-20
Total hip arthroplasty (THA) significantly improves the quality of life in majority of patients with severe osteoarthritis. However, long-term outcomes of THAs are compromised by aseptic loosening and periprosthetic osteolysis which needs revision surgery. Both of these are causally linked to a prosthetic wear deliberated from the prosthetic articulating surfaces. As a result, there is a need to measure the mode and magnitude of wear. The paper evaluates three optical methods proposed for construction of a device for the non-contact prosthetic wear measurement. Of them, the scanning profilometry achieved promising combination of accuracy and repeatability. Simultaneously, it is time efficient to enable the development of a sensor for wear measurement.
Phillips, A T M; Pankaj; Usmani, A S; Howie, C R
2004-01-01
The study uses idealized two-dimensional finite element models to examine the behaviour of the acetabular construct following revision hip arthroplasty, carried out using the Slooff-Ling impaction grafting technique. The behaviour of bone graft was considered in detail, with non-linear elasticity and non-associated plasticity being adopted. Load was applied to the acetabular construct through a femoral head using smooth sliding surfaces. In particular, four models were subjected to two idealized cyclic load cases to investigate the effect of acetabular cup size on the short-term stability of the acetabular construct. The study suggests that benefits may be gained by using the largest practical size of acetabular cup.
Metal-on-Metal Total Hip Resurfacing Arthroplasty
2006-01-01
Executive Summary Objective The objective of this review was to assess the safety and effectiveness of metal on metal (MOM) hip resurfacing arthroplasty for young patients compared with that of total hip replacement (THR) in the same population. Clinical Need Total hip replacement has proved to be very effective for late middle-aged and elderly patients with severe degenerative diseases of the hips. As indications for THR began to include younger patients and those with a more active life style, the longevity of the implant became a concern. Evidence suggests that these patients experience relatively higher rates of early implant failure and the need for revision. The Swedish hip registry, for example, has demonstrated a survival rate in excess of 80% at 20 years for those aged over 65 years, whereas this figure was 33% by 16 years in those aged under 55 years. Hip resurfacing arthroplasty is a bone-conserving alternative to THR that restores normal joint biomechanics and load transfer. The technique has been used around the world for more than 10 years, specifically in the United Kingdom and other European countries. The Technology Metal-on-metal hip resurfacing arthroplasty is an alternative procedure to conventional THR in younger patients. Hip resurfacing arthroplasty is less invasive than THR and addresses the problem of preserving femoral bone stock at the initial operation. This means that future hip revisions are possible with THR if the initial MOM arthroplasty becomes less effective with time in these younger patients. The procedure involves the removal and replacement of the surface of the femoral head with a hollow metal hemisphere, which fits into a metal acetabular cup. Hip resurfacing arthroplasty is a technically more demanding procedure than is conventional THR. In hip resurfacing, the femoral head is retained, which makes it much more difficult to access the acetabular cup. However, hip resurfacing arthroplasty has several advantages over a conventional THR with a small (28 mm) ball. First, the large femoral head reduces the chance of dislocation, so that rates of dislocation are less than those with conventional THR. Second, the range of motion with hip resurfacing arthroplasty is higher than that achieved with conventional THR. A variety of MOM hip resurfacing implants are used in clinical practice. Six MOM hip resurfacing implants have been issued licences in Canada. Review Strategy A search of electronic bibliographies (OVID Medline, Medline In-Process and Other Non-Indexed Citations, Embase, Cochrane CENTRAL and DSR, INAHTA) was undertaken to identify evidence published from Jan 1, 1997 to October 27, 2005. The search was limited to English-language articles and human studies. The literature search yielded 245 citations. Of these, 11 met inclusion criteria (9 for effectiveness, 2 for safety). The result of the only reported randomized controlled trial on MOM hip resurfacing arthroplasty could not be included in this assessment, because it used a cemented acetabular component, whereas in the new generation of implants, a cementless acetabular component is used. After omitting this publication, only case series remained. Summary of Findings Health Outcomes The Harris hip score and SF-12 are 2 measures commonly used to report health outcomes in MOM hip resurfacing arthroplasty studies. Other scales used are the Oxford hip score and the University of California Los Angeles hip score. The case series showed that the mean revision rate of MOM hip resurfacing arthroplasty is 1.5% and the incidence of femoral neck fracture is 0.67%. Across all studies, 2 cases of osteonecrosis were reported. Four studies reported improvement in Harris hip scores. However, only 1 study reported a statistically significant improvement. Three studies reported improvement in SF-12 scores, of which 2 reported a significant improvement. One study reported significant improvement in UCLA hip score. Two studies reported postoperative Oxford hip scores, but no preoperative values were reported. None of the reviewed studies reported procedure-related deaths. Four studies reported implant survival rates ranging from 94.4% to 99.7% for a follow-up period of 2.8 to 3.5 years. Three studies reported on the range of motion. One reported improvement in all motions including flexion, extension, abduction-adduction, and rotation, and another reported improvement in flexion. Yet another reported improvement in range of motion for flexion abduction-adduction and rotation arc. However, the author reported a decrease in the range of motion in the arc of flexion in patients with Brooker class III or IV heterotopic bone (all patients were men). Safety of Metal-on-Metal Hip Resurfacing Arthroplasty There is a concern about metal wear debris and its systemic distribution throughout the body. Detectable metal concentrations in the serum and urine of patients with metal hip implants have been described as early as the 1970s, and this issue is still controversial after 35 years. Several studies have reported high concentration of cobalt and chromium in serum and/or urine of the patients with metal hip implants. Potential toxicological effects of the elevated metal ions have heightened concerns about safety of MOM bearings. This is of particular concern in young and active patients in whom life expectancy after implantation is long. Since 1997, 15 studies, including 1 randomized clinical trial, have reported high levels of metal ions after THR with metal implants. Some of these studies have reported higher metal levels in patients with loose implants. Adverse Biological Effects of Cobalt and Chromium Because patients who receive a MOM hip arthroplasty are shown to be exposed to high concentrations of metallic ions, the Medical Advisory Secretariat searched the literature for reports of adverse biological effects of cobalt and chromium. Cobalt and chromium make up the major part of the metal articulations; therefore, they are a focus of concern. Risk of Cancer To date, only one study has examined the incidence of cancer after MOM and polyethylene on metal total hip arthroplasties. The results were compared to that of general population in Finland. The mean duration of follow-up for MOM arthroplasty was 15.7 years; for polyethylene arthroplasty, it was 12.5 years. The standardized incidence ratio for all cancers in the MOM group was 0.95 (95% CI, 0.79–1.13). In the polyethylene on metal group it was 0.76 (95% CI, 0.68–0.86). The combined standardized incidence ratio for lymphoma and leukemia in the patients who had MOM THR was 1.59 (95% CI, 0.82–2.77). It was 0.59 (95% CI, 0.29–1.05) for the patients who had polyethylene on metal THR. Patients with MOM THR had a significantly higher risk of leukemia. All patients who had leukemia were aged over than 60 years. Cobalt Cardiotoxicity Epidemiological Studies of Myocardiopathy of Beer Drinkers An unusual type of myocardiopathy, characterized by pericardial effusion, elevated hemoglobin concentrations, and congestive heart failure, occurred as an epidemic affecting 48 habitual beer drinkers in Quebec City between 1965 and 1966. This epidemic was directly related the consumption of a popular beer containing cobalt sulfate. The epidemic appeared 1 month after cobalt sulfate was added to the specific brewery, and no further cases were seen a month after this specific chemical was no longer used in making this beer. A beer of the same name is made in Montreal, and the only difference at that time was that the Quebec brand of beer contained about 10 times more cobalt sulphate. Cobalt has been added to some Canadian beers since 1965 to improve the stability of the foam but it has been added in larger breweries only to draught beer. However, in small breweries, such as those in Quebec City, separate batches were not brewed for bottle and draught beer; therefore, cobalt was added to all of the beer processed in this brewery. In March 1966, a committee was appointed under the chairmanship of the Deputy Minister of Health for Quebec that included members of the department of forensic medicine of Quebec’s Ministry of Justice, epidemiologists, members of Food and Drug Directorate of Ottawa, toxicologists, biomedical researchers, pathologists, and members of provincial police. Epidemiological studies were carried out by the Provincial Ministry of Health and the Quebec City Health Department. The association between the development of myocardiopathy and the consumption of the particular brand of beer was proven. The mortality rate of this epidemic was 46.1% and those who survived were desperately ill, and recovered only after a struggle for their lives. Similar cases were seen in Omaha (Nebraska). The epidemic started after a cobalt additive was used in 1 of the beers marketed in Nebraska. Sixty-four patients with the clinical diagnosis of alcoholic myocardiopathy were seen during an 18-month period (1964–1965). Thirty of these patients died. The first patient became ill within 1 month after cobalt was added to the beer, and the last patient was seen within 1 month of withdrawal of cobalt. A similar epidemic occurred in Minneapolis, Minnesota. Between 1964 and 1967, 42 patients with acute heart failure were admitted to a hospital in Minneapolis, Minnesota. Twenty of these patients were drinking 6 to 30 bottles per day of a particular brand of beer exclusively. The other 14 patients also drank the same brand of beer, but not exclusively. The mortality rate from the acute illness was 18%, but late deaths accounted for a total mortality rate of 43%. Examination of the tissue from these patients revealed markedly abnormal changes in myofibrils (heart muscles), mitochondria, and sarcoplasmic reticulum. In Belgium, a similar epidemic was reported in 1966, in which, cobalt was used in some Belgian beers. There was a difference in mortality between the Canadian or American epidemic and this series. Only 1 of 24 patients died, 1.5 years after the diagnosis. In March 1965, at an international meeting in Brussels, a new heart disease in chronic beer drinkers was described. This disease consists of massive pericardial effusion, low cardiac output, raised venous pressure, and polycythemia in some cases. This syndrome was thought to be different from the 2 other forms of alcoholic heart disease (beriberi and a form characterized by myocardial fibrosis). The mystery of the above epidemics as stated by investigators is that the amount of cobalt added to the beer was below the therapeutic doses used for anemia. For example, 24 pints of Quebec brand of beer in Quebec would contain 8 mg of cobalt chloride, whereas an intake of 50 to 100 mg of cobalt as an antianemic agent has been well tolerated. Thus, greater cobalt intake alone does not explain the occurrence of myocardiopathy. It seems that there are individual differences in cobalt toxicity. Other features, like subclinical alcoholic heart disease, deficient diet, and electrolyte imbalance could have been precipitating factors that made these patients susceptible to cobalt’s toxic effects. In the Omaha epidemic, 60% of the patients had weight loss, anorexia, and occasional vomiting and diarrhea 2 to 6 months before the onset of cardiac symptoms. In the Quebec epidemic, patients lost their appetite 3 to 6 months before the diagnosis of myocardiopathy and developed nausea in the weeks before hospital admission. In the Belgium epidemic, anorexia was one of the most predominant symptoms at the time of diagnosis, and the quality and quantity of food intake was poor. Alcohol has been shown to increase the uptake of intracoronary injected cobalt by 47%. When cobalt enters the cells, calcium exits; this shifts the cobalt to calcium ratio. The increased uptake of cobalt in alcoholic patients may explain the high incidence of cardiomyopathies in beer drinkers’ epidemics. As all of the above suggest, it may be that prior chronic exposure to alcohol and/or a nutritionally deficient diet may have a marked synergistic effect with the cardiotoxicity of cobalt. Conclusions MOM hip resurfacing arthroplasty has been shown to be an effective arthroplasty procedure as tested in younger patients. However, evidence for effectiveness is based only on 7 case series with short duration of follow-up (2.8–3.5 years). There are no RCTs or other well-controlled studies that compare MOM hip resurfacing with THR. Revision rates reported in the MOM studies using implants currently licensed in Canada (hybrid systems, uncemented acetabular, and cemented femoral) range from 0.3% to 3.6% for a mean follow-up ranging from 2.8 to 3.5 years. Fracture of femoral neck is not very common; it occurs in 0.4% to 2.2% of cases (as observed in a short follow-up period). All the studies that measured health outcomes have reported improvement in Harris Hip and SF-12 scores; 1 study reported significant reduction in pain and improvement in function, and 2 studies reported significant improvement in SF-12 scores. One study reported significant improvement in UCLA Hip scores. Concerns remain on the potential adverse effects of metal ions. Longer-term follow-up data will help to resolve the inconsistency of findings on adverse effects, including toxicity and carcinogenicity. Ontario-Based Economic Analysis The device cost for MOM ranges from $4,300 to $6,000 (Cdn). Traditional hip replacement devices cost about $2,000 (Cdn). Using Ontario Case Costing Initiative data, the total estimated costs for hip resurfacing surgery including physician fees, device fees, follow-up consultation, and postsurgery rehabilitation is about $15,000 (Cdn). Figure 1: Cost of Total Hip Replacement Surgery in Ontario Hip Resurfacing Surgery (Based on 2005/06 inflationary-adjusted rates) Weighted Average (Academic Community! al-inclusive hospitalization cost of surgery $ 6.767.18 Device Cost $ 5,400.00 Additional Medication $ 330.75 Follow-up Consultation $ 190.30 Rehab (per outpatient CCAC case) $ 1,500.00 OH P costs (average) $ 1,068.60 Total Estimated Cost $ 15,256.83 MOM hip arthroplasty is generally recommended for patients aged under 55 years because its bone-conserving advantage enables patients to “buy time” and hence helps THRs to last over the lifetime of the patient. In 2004/2005, 15.9% of patients who received THRs were aged 55 years and younger. It is estimated that there are from 600 to 1,000 annual MOM hip arthroplasty surgeries in Canada with an estimated 100 to 150 surgeries in Ontario. Given the increased public awareness of this device, it is forecasted that demand for MOM hip arthroplasty will steadily increase with a conservative estimate of demand rising to 1,400 cases by 2010 (Figure 10). The net budget impact over a 5-year period could be $500,000 to $4.7 million, mainly because of the increasing cost of the device. Figure 2: Projected Number of Metal-on-Metal Hip Arthroplasty Surgeries in Ontario: to 2010 PMID:23074495
The effect of surgeon and hospital volume on shoulder arthroplasty perioperative quality metrics.
Singh, Anshu; Yian, Edward H; Dillon, Mark T; Takayanagi, Miwa; Burke, Mary F; Navarro, Ronald A
2014-08-01
There has been a significant increase in both the incidence of shoulder arthroplasty and the number of surgeons performing these procedures. Literature regarding the relationship between surgeon or hospital volume and the performance of modern shoulder arthroplasty is limited. This study examines the effect of surgeon or hospital shoulder arthroplasty volume on perioperative metrics related to shoulder hemiarthroplasty, total shoulder arthroplasty, and reverse shoulder arthroplasty. Blood loss, length of stay, and operative time were the main endpoints analyzed. Prospective data were analyzed from a multicenter shoulder arthroplasty registry; 1176 primary shoulder arthroplasty cases were analyzed. Correlation and analysis of covariance were used to examine the association between surgeon and hospital volume and perioperative metrics adjusting for age, sex, and body mass index. Surgeon volume is inversely correlated with length of stay for hemiarthroplasty and total shoulder arthroplasty and with blood loss and operative time for all 3 procedures. Hospital volume is inversely correlated with length of stay for hemiarthroplasty, with blood loss for total and reverse shoulder arthroplasty, and with operative time for all 3 procedures. High-volume surgeons performed shoulder arthroplasty 30 to 50 minutes faster than low-volume surgeons did. Higher surgeon and hospital case volumes led to improved perioperative metrics with all shoulder arthroplasty procedures, including reverse total shoulder arthroplasty, which has not been previously described in the literature. Surgeon volume had a larger effect on metrics than hospital volume did. This study supports the concept that complex shoulder procedures are, on average, performed more efficiently by higher volume surgeons in higher volume centers. Copyright © 2014 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.
Economic Analysis of 4221 Revisions Due to Periprosthetic Joint Infection in Poland.
Babiak, Ireneusz; Pędzisz, Piotr; Janowicz, Jakub; Kulig, Mateusz; Małdyk, Paweł
2017-01-26
Periprosthetic joint infection (PJI) is one of the most severe complications of total hip (THA) and total knee (TKA) arthroplasty. The aim of the study is to determine the number and type of hip and knee prosthesis revisions in Poland performed due to infection and reimbursement of the cost of septic revisions and to compare the costs of septic and aseptic revisions in Poland and other countries. The data published for the period 2009-2013 by the National Health Fund (NHF) were analysed and the average cost of septic and aseptic revisions was calculated. In the years 2009-2013, a total of 260,030 hip and knee arthroplasties including 23,027 revisions (incl. 4,221 septic) were performed in Poland. In 2013, septic revisions accounted for 1.38% of all hip replacement procedures, 2.56% of all knee replacement procedures and 14.67% of all hip revisions and 30.23% of all knee revisions. In 2013, the difference between the average cost incurred by the hospital and the NHF refund for septic revision due to PJI was at least €238 and the cost-refund gap for the entire year was €219198. 1. The system of reporting periprostheticjoint infections currently in use in Poland does not adequately reflect the current classification of PJI and reimbursement for septic revision of joint prosthesis does not match the actual costs. 2. The Polish DRG system does not distinguish between early and late PJI and fails to acknowledge basic guidelines for infection treatment currently followed in Poland and worldwide. 3. According to the DRG system, patients requiring different treatment are placed in one category. 4. Until the year 2013, the less expensive treatment of early infections had been reimbursed on the same basis as the more costly two-stage revision procedures.
Thirteen-year outcomes in the Anatomique Benoist Girard II hip prosthesis.
Catanach, Michael J M; Sorial, Rami M; Eslick, Guy D
2015-04-01
The Stryker Anatomique Benoist Girard (ABG) hip implant system was a commonly used cementless prosthesis in the early 2000s, which fell from favour after several studies emerged implicating the prosthesis in high rates of revision. This retrospective, single-surgeon clinical study examines the fracture rate, revision rate and reasons for revision in 500 consecutive ABG II primary total conventional hip replacements. Follow-up was conducted by audit of patient notes, patient mailout survey, patient phone contact and audit of the Australian National Joint Replacement Registry (NJRR) database to find instances of fracture and revision. End points were periprosthetic fracture and revision for any reason. Follow-up was 1.2-13.8 years with a mean of 6.58 years. Of the 500 hips, 17 (3.4%) had undergone a revision. Of these, 13 were due to periprosthetic fracture. Four further fractures occurred that were not revised. Eight of these periprosthetic fractures occurred within 1 year post-operatively. There were four revisions for recurrent dislocations. Kaplan-Meier survival curve demonstrates a 93.7% survivorship at 6.58 years for revision for any reason. Multivariate analysis showed the only statistically significant factor for increased risk of revision was smaller stem size. Our results were consistent with the literature in that the ABG II system has good medium-term results but is prone to periprosthetic fractures, especially in the early post-operative period. When used as a primary total hip arthroplasty, the ABG II system has an 8-year revision rate of 5.6% compared with the 4.9% of all primary total hip arthroplasties. © 2014 Royal Australasian College of Surgeons.
Early results of patellofemoral inlay resurfacing arthroplasty using the HemiCap Wave prosthesis.
Patel, Akash; Haider, Zakir; Anand, Amarjit; Spicer, Dominic
2017-01-01
Common surgical treatment options for isolated patellofemoral osteoarthritis include arthroscopic procedures, total knee replacement and patellofemoral replacement. The HemiCap Wave patellofemoral resurfacing prosthesis is a novel inlay design introduced in 2009 with scarce published data on its functional outcomes. We aim to prospectively evaluate early functional outcomes and complications, for patients undergoing a novel inlay resurfacing arthroplasty for isolated patellofemoral arthrosis in an independent centre. From 2010 to 2013, 16 consecutive patients underwent patellofemoral resurfacing procedures using HemiCap Wave (Arthrosurface Inc., Franklin, Massachusetts, USA) for anterior knee pain with confirmed radiologically and/or arthroscopically isolated severe patellofemoral arthrosis. Standardized surgical technique, as recommended by the implant manufacturer, was followed. Outcome measures included range of movement, functional knee scores (Oxford Knee Score (OKS), Knee Injury and Osteoarthritis Outcome Score (KOOS) and Short Form-36 (SF-36)), radiographic disease progression, revision rates and complications. Eight men and eight women underwent patellofemoral HemiCap Wave resurfacing, with an average age of 63 years (range: 46-83). Average follow-up was 24.1 months (6-34). Overall, post-operative scores were excellent. There was a statistically significant improvement in the post-operative OKS, KOOS and SF-36 scores ( p < 0.01). One patient had radiological disease progression. One patient underwent revision for deep infection. Two other minor complications were observed and treated conservatively. The HemiCap Wave patellofemoral resurfacing prosthesis has excellent early results in terms of functional outcomes, radiological outcomes and low complication rates. At the very least, early results show that the HemiCap Wave is comparable to more established onlay prostheses. The HemiCap Wave thus provides a safe and effective surgical option in the treatment of isolated patellofemoral osteoarthritis in selected patients.
Correction of Patellofemoral Malalignment With Patellofemoral Arthroplasty.
Valoroso, Marco; Saffarini, Mo; La Barbera, Giuseppe; Toanen, Cécile; Hannink, Gerjon; Nover, Luca; Dejour, David H
2017-12-01
The goal of patellofemoral arthroplasty (PFA) is to replace damaged cartilage and correct underlying deformities to reduce pain and prevent maltracking. We aimed to determine how PFA modifies patellar height, tilt, and tibial tuberosity-trochlear groove (TT-TG) distance. The hypothesis was that PFA would correct trochlear dysplasia or extensor mechanism malalignment. The authors prospectively studied a series of 16 patients (13 women and 3 men) aged 64.9 ± 16.3 years (range 41-86 years) who received PFA. All knees were assessed preoperatively and 6 months postoperatively using frontal, lateral, and "skyline" x-rays, and computed tomography scans to calculate patellar tilt, patellar height, and TT-TG distance. The interobserver agreement was excellent for all parameters (intraclass correlation coefficient >0.95). Preoperatively, the median patellar tilt without quadriceps contraction (QC) was 17.5° (range 5.3°-33.4°) and with QC was 19.8° (range 0°-52.0°). The median Caton-Deschamps index was 0.91 (range 0.80-1.22) and TT-TG distance was 14.5 mm (range 4.0-22.0 mm). Postoperatively, the median patellar tilt without QC was 0.3° (range -15.3° to 9.5°) and with QC was 6.1° (range -11.5° to 13.3°). The median Caton-Deschamps index was 1.11 (range 0.81-1.20) and TT-TG distance was 10.1 mm (range 1.8-13.8 mm). The present study demonstrates that beyond replacing arthritic cartilage, trochlear-cutting PFA improves patellofemoral congruence by correcting trochlear dysplasia and standardizing radiological measurements as patellar tilt and TT-TG. The association of lateral patellar facetectomy improves patellar tracking by reducing the patellar tilt. Copyright © 2017 Elsevier Inc. All rights reserved.
Globalization of health care delivery in the United States through medical tourism.
Kumar, Sameer; Breuing, Richard; Chahal, Rajneet
2012-01-01
This study highlights some of the inefficiencies in the U.S. health care system and determines what effect medical tourism has had on the U.S. and global health care supply chains. This study also calls attention to insufficient health communication efforts to inform uninsured or underinsured medical tourists about the benefits and risks and determines the managerial and cost implications of various surgical procedures on the global health care system into the future. This study evaluated 3 years (2005, 2007, and 2011) of actual and projected surgical cost data. The authors selected 3 countries for analysis: the United States, India, and Thailand. The surgeries chosen for evaluation were total knee replacement (knee arthroplasty), hip replacement (hip arthroplasty), and heart bypass (coronary artery bypass graft). Comparisons of costs were made using Monte Carlo simulation with variability encapsulated by triangular distributions. The results are staggering. In 2005, the amount of money lost to India and Thailand on just these 3 surgeries because of cost inefficiencies in the U.S. health care system was between 1.3 to 2 billion dollars. In 2011, because many more Americans are expected to travel overseas for health care, this amount is anticipated to rise to between 20 and 30.2 billion dollars. Therefore, more attention should be paid to health communication efforts that truly illustrate the benefits/risks of medical travel. The challenge of finding reliable data for surgeries performed and associated surgical cost estimates was mitigated by the use of a Monte Carlo simulation of triangular distributions. The implications from this study are clear: If the U.S. health care industry is unable to eliminate waste and inefficiency and thus curb rising costs, it will continue to lose surgical revenue to foreign health providers. Copyright © Taylor & Francis Group, LLC
Metal-on-Metal Total Hip Arthroplasty: Quality of Online Patient Information.
Crozier-Shaw, Geoff; Queally, Joseph M; Quinlan, John F
2017-03-01
Metal-on-metal total hip arthroplasty (THA) has generated much attention in the media because of early failure of certain implant systems. This study assessed the quality, accuracy, and readability of online information on metal-on-metal THA. The search terms "metal-on-metal hip replacement" and "metal hip replacement" were entered into the 3 most popular search engines. Information quality was assessed with the DISCERN score and a specific metal-on-metal THA content score. Accuracy of information was assessed with a customized score. Readability of the websites was assessed with the Flesch-Kincaid grade level score. A total of 61 unique websites were assessed. For 56% of websites, the target audience was patients. Media or medicolegal sources accounted for 44% of websites. As assessed by DISCERN (range, 16-80) and metal-on-metal THA (range, 0-25) scores, quality of the websites was moderate at best (47.1 and 9.6, respectively). Accuracy (range, 0-8) of the information presented also was moderate, with a mean score of 6.6. Media and medicolegal websites had the lowest scores for both quality and accuracy, despite making up the greatest proportion of sites assessed. Only 1 website (2%) had a Flesch-Kincaid grade level at or less than the recommended level of 8th grade. This study found that online information on metal-on-metal THA was of poor quality, often was inaccurate, and was presented at an inappropriately high reading level, particularly for media and medicolegal websites. Health care providers should counsel patients on the quality of information available and recommend appropriate online resources. [Orthopedics. 2017; 40(2):e262-e268.]. Copyright 2016, SLACK Incorporated.
NASA Astrophysics Data System (ADS)
Wannaphan, Patsiri; Chanthasopeephan, Teeranoot
2016-11-01
Knee rehabilitation after total knee replacement arthroplasty is essential for patients during their post-surgery recovery period. This study is about designing one degree of freedom knee rehabilitation equipment to assist patients for their post-surgery exercise. The equipment is designed to be used in sitting position with flexion/extension of knee in sagittal plane. The range of knee joint motion is starting from 0 to 90 degrees angle for knee rehabilitation motion. The feature includes adjustable link for different human proportions and the torque feedback control at knee joint during rehabilitation and the control of flexion/extension speed. The motion of the rehabilitation equipment was set to move at low speed (18 degrees/sec) for knee rehabilitation. The rehabilitation link without additional load took one second to move from vertical hanging up to 90° while the corresponding torque increased from 0 Nm to 2 Nm at 90°. When extra load is added, the link took 1.5 seconds to move to 90° The torque is then increased from 0 Nm to 4 Nm. After a period of time, the speed of the motion can be varied. User can adjust the motion to 40 degrees/sec during recovery activity of the knee and users can increase the level of exercise or motion up to 60 degrees/sec to strengthen the muscles during throughout their rehabilitation program depends on each patient. Torque control is included to prevent injury. Patients can use the equipment for home exercise to help reduce the number of hospital visit while the patients can receive an appropriate therapy for their knee recovery program.
Li, Chaodi; Kotha, Shiva; Mason, James
2003-01-01
The exothermic polymerization of bone cement may induce thermal necrosis of bone in cemented hip arthroplasty. A finite element formulation was developed to predict the evolution of the temperature with time in the cemented hip replacement system. The developed method is capable of taking into account both the chemical reaction that generates heat during bone cement polymerization (through a kinetic model) and the physical process of heat conduction (with an energy balance equation). The possibility of thermal necrosis of bone was then evaluated based on the temperature history in the bone and an appropriate damage criterion. Specifically, we evaluate the role of implant materials and designs on the thermal response of the system. Results indicated that the peak temperature at the bone/cement interface with a metal prosthesis was lower than that with a polymer or a composite prosthesis in hip replacement systems. Necrosis of bone was predicted to occur with a polymer or a composite prosthesis while no necrosis was predicted with a metal prosthesis in the simulated conditions. When reinforcing osteoporotic hips with injected bone cement in the cancellous core of the femur, the volume of bone cement implanted is increased which may increase the risk of thermal necrosis of bone. We evaluate whether this risk can be decreased through the use of an insulator to contain the bone cement. No thermal necrosis of bone was predicted with a 3 mm thick polyurethane insulator while more damage is predicted for the use of bone cement without the insulator. This method provides a numerical tool for the quantitative simulation of the thermal behavior of bone-cement-prosthesis designs and for examining and refining new designs computationally.
Choi, H J; Adiyani, L; Sung, J; Choi, J Y; Kim, H B; Kim, Y K; Kwak, Y G; Yoo, H; Lee, Sang-Oh; Han, S H; Kim, S R; Kim, T H; Lee, H M; Chun, H K; Kim, J-S; Yoo, J D; Koo, H-S; Cho, E H; Lee, K W
2016-08-01
Surveillance of healthcare-associated infection has been associated with a reduction in surgical site infection (SSI). To evaluate the Korean Nosocomial Infection Surveillance System (KONIS) in order to assess its effects on SSI since it was introduced. SSI data after gastrectomy, total hip arthroplasty (THA), and total knee arthroplasty (TKA) between 2008 and 2012 were analysed. The pooled incidence of SSI was calculated for each year; the same analyses were also conducted from hospitals that had participated in KONIS for at least three consecutive years. Standardized SSI rates for each year were calculated by adjusting for SSI risk factors. SSI trends were analysed using the Cochran-Armitage test. The SSI rate following gastrectomy was 3.12% (522/16,918). There was a significant trend of decreased crude SSI rates over five years. This trend was also evident in analysis of hospitals that had participated for more than three years. The SSI rate for THA was 2.05% (157/7656), which decreased significantly from 2008 to 2012. The risk factors for SSI after THA included the National Nosocomial Infections Surveillance risk index, trauma, reoperation, and age (60-69 years). The SSI rate for TKA was 1.90% (152/7648), which also decreased significantly during a period of five years. However, the risk-adjusted analysis of SSI did not show a significant decrease for all surgical procedures. The SSI incidence of gastrectomy and prosthetic joint replacement declined over five years as a result of active surveillance by KONIS. Copyright © 2016 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.
Richter, Berna I; Ostermeier, Sven; Turger, Anke; Denkena, Berend; Hurschler, Christof
2010-06-15
Material wear testing is an important technique in the development and evaluation of materials for use in implant for total knee arthroplasty. Since a knee joint induces a complex rolling-gliding movement, standardised material wear testing devices such as Pin-on-Disc or Ring-on-Disc testers are suitable to only a limited extent because they generate pure gliding motion only. A rolling-gliding wear simulator was thus designed, constructed and implemented, which simulates and reproduces the rolling-gliding movement and loading of the knee joint on specimens of simplified geometry. The technical concept was to run a base-plate, representing the tibia plateau, against a pivoted cylindrical counter-body, representing one femur condyle under an axial load. A rolling movement occurs as a result of the friction and pure gliding is induced by limiting the rotation of the cylindrical counter-body. The set up also enables simplified specimens handling and removal for gravimetrical wear measurements. Long-term wear tests and gravimetrical wear measurements were carried out on the well known material pairings: cobalt chrome-polyethylene, ceramic-polyethylene and ceramic-ceramic, over three million motion cycles to allow material comparisons to be made. The observed differences in wear rates between cobalt-chrome on polyethylene and ceramic on polyethylene pairings were similar to the differences of published data for existing material-pairings. Test results on ceramic-ceramic pairings of different frontal-plane geometry and surface roughness displayed low wear rates and no fracture failures. The presented set up is able to simulate the rolling-gliding movement of the knee joint, is easy to use, and requires a minimum of user intervention or monitoring. It is suitable for long-term testing, and therefore a useful tool for the investigation of new and promising materials which are of interest for application in knee joint replacement implants.
2010-01-01
Background Material wear testing is an important technique in the development and evaluation of materials for use in implant for total knee arthroplasty. Since a knee joint induces a complex rolling-gliding movement, standardised material wear testing devices such as Pin-on-Disc or Ring-on-Disc testers are suitable to only a limited extent because they generate pure gliding motion only. Methods A rolling-gliding wear simulator was thus designed, constructed and implemented, which simulates and reproduces the rolling-gliding movement and loading of the knee joint on specimens of simplified geometry. The technical concept was to run a base-plate, representing the tibia plateau, against a pivoted cylindrical counter-body, representing one femur condyle under an axial load. A rolling movement occurs as a result of the friction and pure gliding is induced by limiting the rotation of the cylindrical counter-body. The set up also enables simplified specimens handling and removal for gravimetrical wear measurements. Long-term wear tests and gravimetrical wear measurements were carried out on the well known material pairings: cobalt chrome-polyethylene, ceramic-polyethylene and ceramic-ceramic, over three million motion cycles to allow material comparisons to be made. Results The observed differences in wear rates between cobalt-chrome on polyethylene and ceramic on polyethylene pairings were similar to the differences of published data for existing material-pairings. Test results on ceramic-ceramic pairings of different frontal-plane geometry and surface roughness displayed low wear rates and no fracture failures. Conclusions The presented set up is able to simulate the rolling-gliding movement of the knee joint, is easy to use, and requires a minimum of user intervention or monitoring. It is suitable for long-term testing, and therefore a useful tool for the investigation of new and promising materials which are of interest for application in knee joint replacement implants. PMID:20550669
Kirschner, S; Konrad, T; Weil, E J; Bühler, M
2004-07-01
Arterial complications after total knee arthroplasty are rare. If the formation of a false aneurysm does occur, it usually affects the popliteal artery. We report the case of an 77 year old female with a false aneurysm of the lateral superior genicular artery. The patient was suffering from gonarthrosis and received a duocondylar knee replacement without resurfacing of the patella. Postoperatively, she reported anterior knee pain and a revision of the joint with lateral release was carried out. In the third postoperative week, a painful swelling in the lateral and superior aspect of the knee occurred. A scintigraphic investigation with enrichment in the early period was misinterpreted as infection. Ultrasonographic and angiographic investigations gave the right diagnosis of a false aneurysm. In the same angiographic investigation, the aneurysm could be cured by coil embolisation. The interval between the operation leading to the problem and the formation of the aneurysm, as well as the low incidence of this complication, made it hard to diagnose. Ultrasonographic and angiographic examinations allow for proper diagnosis in cases of unclear painful swellings. When dealing with an arterial complication following total knee arthroplasty, a specialized radiologist or vascular surgeon should be consulted immediately.
Periosteal pseudotumor in complex total knee arthroplasty resembling a neoplastic process.
Chowdhry, Madhav; Dipane, Matthew V; McPherson, Edward J
2018-05-18
This case report describes in detail an erosive distal diaphyseal pseudotumor that occurred 6 years after a complex endoprosthetic hinge total knee arthroplasty (TKA). A female patient had conversion of a knee fusion to an endoprosthetic hinge TKA at the age of 62. At her scheduled 6-year follow-up, she presented with mild distal thigh pain and radiographs showing a 6-7 cm erosive lytic diaphyseal lesion that looked very suspicious for a neoplastic process. An en bloc resection of the distal femur and femoral endoprosthesis was performed. Histologic review showed the mass to be a pseudotumor with the wear debris emanating from within the femoral canal due to distal stem loosening. We deduce that mechanized stem abrasion created microscopic titanium alloy particles that escaped via a small diaphyseal crack and stimulated an inflammatory response resulting in a periosteal erosive pseudotumor. The main lesson of this report is that, in the face of a joint replacement surgery of the knee, pseudotumor formation is a more likely diagnosis than a neoplastic process when encountering an expanding bony mass. Thus, a biopsy prior to en bloc resection, would be our recommended course of action any time a suspicious mass is encountered close to a TKA.
2014-01-01
Background This study hopes to establish the timeframe for a safe return to driving under different speed conditions for patients after minimally invasive total knee arthroplasty and further explores how well various kinds of functional tests on knee performance can predict the patients’ braking ability. Methods 14 patients with right knee osteoarthritis were included in the present study and instructed to perform three simulated driving tasks at preoperative, 2 weeks postoperative and 4 weeks postoperative. Results The results showed that the total braking time at 4 week postoperative has attained the preoperative level at the driving speed 50 and 70 km/hr but not at the driving speed 90 km/hr. It had significantly improving in knee reaction time and maximum isometric force at 4 weeks postoperative. Besides, there was a moderate to high correlation between the scores of the step counts and the total braking time. Conclusions Summary, it is recommended that driving may be resumed 4 weeks after a right knee replacement but had to drive at low or moderate speed and the best predictor of safety driving is step counts. PMID:24913312
Rapid rehabilitation and recovery with minimally invasive total hip arthroplasty.
Berger, Richard A; Jacobs, Joshua J; Meneghini, R Michael; Della Valle, Craig; Paprosky, Wayne; Rosenberg, Aaron G
2004-12-01
To assess the potential recovery rate of a minimally invasive total hip replacement technique with minimal soft tissue disruption, an accelerated rehabilitation protocol was implemented with weightbearing as tolerated on the day of surgery. One hundred consecutive patients were enrolled in this prospective study. Ninety-seven patients (97%) met all the inpatient physical therapy goals required for discharge to home on the day of surgery; 100% of patients achieved these goals within 23 hours of surgery. Outpatient therapy was initiated in 9% of patients immediately, 62% of patients by 1 week, and all patients by 2 weeks. The mean time to discontinued use of crutches, discontinued use of narcotic pain medications, and resumed driving was 6 days postoperatively. The mean time to return to work was 8 days, discontinued use of any assistive device was 9 days, and resumption of all activities of daily living was 10 days. The mean time to walk (1/2) mile was 16 days. Furthermore, there were no readmissions, no dislocations, and no reoperations. Therefore, a rapid rehabilitation protocol is safe and fulfills the potential benefits of a rapid recovery with minimally invasive total hip arthroplasty.
Lenguerrand, Erik; Whitehouse, Michael R; Wylde, Vikki; Gooberman-Hill, Rachael; Blom, Ashley W
2016-01-01
Patients report similar or better pain and function before revision hip arthroplasty than before primary arthroplasty but worse results are reported after revision surgery than after primary surgery. The trajectory of post-operative recovery during the first months and any differences by type of surgery have received little attention. We explored the trajectories of change in pain and function after revision hip arthroplasty to 12-months post-operatively and compare them with those observed after primary hip arthroplasty. This study is a prospective cohort study of patients undergoing primary (n = 80 with 92% for an indication of osteoarthritis) and revision (n = 43) hip arthroplasties. WOMAC pain and function scores and walking speed were collected pre-operatively, at 3 and 12-months post-operatively. Multilevel regression models were used to chart and compare the trajectories of change (0-3 months and 3-12 months) between types of surgery. The improvements in pain and function following revision arthroplasty occurred within the first 3-months with no evidence of further change beyond this initial period. While the pattern of recovery was similar to the one observed after primary arthroplasty, improvements in the first 3-months were smaller after revision compared to primary arthroplasty. Patients listed for revision surgery reported lower pre-operative pain levels but similar post-operative levels compared to those undergoing primary surgery. At 12-months post-operation patients who underwent a revision arthroplasty had not reached the same level of function achieved by those who underwent primary arthroplasty. The post-operative improvements in pain and function are larger following primary hip arthroplasty than following revision hip arthroplasty. Irrespectively of surgery type, most of the improvements occur in the first three post-operative months. More research is required to identify whether the recovery following revision surgery could be improved with specific post-operative interventions.
New alternate bearing surfaces in total hip arthroplasty: A review of the current literature.
Grieco, Preston W; Pascal, Scott; Newman, Jared M; Shah, Neil V; Stroud, Sarah G; Sheth, Neil P; Maheshwari, Aditya V
2018-01-01
As indications for total hip arthroplasty (THA) have expanded, the incidence of THA has increased among younger patients, who live longer and tend to place more strain on implants via higher activity levels. This demographical shift accentuates the importance of advancing innovation to ensure implant longevity for younger and more active patients. Future innovation, as it pertains to THA components, is likely to focus on modifying implant designs and tribology in conjunction with identification and application of newer biomaterials. By reviewing the literature for development status of various materials and novel design advancements in THA component outside of the standard highly cross-linked polyethylene, this investigation provided an update on the current and future status of design initiatives as they pertain to THA. Though the highlighted alternative bearing surfaces have shown promising in vitro and limited, yet encouraging clinical data, they lack larger and longer-term clinical trial results. Further research and innovation is warranted to identify the optimal bearing surface to most effectively accommodate for the trend of younger and more active patients undergoing THA. Implant longevity is crucial if the clinical success of THA is to be maintained.
Hexter, A T; Hislop, S M; Blunn, G W; Liddle, A D
2018-02-01
Periprosthetic joint infection (PJI) is a serious complication of total hip arthroplasty (THA). Different bearing surface materials have different surface properties and it has been suggested that the choice of bearing surface may influence the risk of PJI after THA. The objective of this meta-analysis was to compare the rate of PJI between metal-on-polyethylene (MoP), ceramic-on-polyethylene (CoP), and ceramic-on-ceramic (CoC) bearings. Electronic databases (Medline, Embase, Cochrane library, Web of Science, and Cumulative Index of Nursing and Allied Health Literature) were searched for comparative randomized and observational studies that reported the incidence of PJI for different bearing surfaces. Two investigators independently reviewed studies for eligibility, evaluated risk of bias, and performed data extraction. Meta-analysis was performed using the Mantel-Haenzel method and random-effects model in accordance with methods of the Cochrane group. Our search strategy revealed 2272 studies, of which 17 met the inclusion criteria and were analyzed. These comprised 11 randomized controlled trials and six observational studies. The overall quality of included studies was high but the observational studies were at high risk of bias due to inadequate adjustment for confounding factors. The overall cumulative incidence of PJI across all studies was 0.78% (1514/193 378). For each bearing combination, the overall incidence was as follows: MoP 0.85% (1353/158 430); CoP 0.38% (67/17 489); and CoC 0.53% (94/17 459). The meta-analysis showed no significant difference between the three bearing combinations in terms of risk of PJI. On the basis of the clinical studies available, there is no evidence that bearing choice influences the risk of PJI. Future research, including basic science studies and large, adequately controlled registry studies, may be helpful in determining whether implant materials play a role in determining the risk of PJI following arthroplasty surgery. Cite this article: Bone Joint J 2018;100-B:134-42. ©2018 The British Editorial Society of Bone & Joint Surgery.
Yoon, Pil Whan; Kim, Yunjung; Yoo, Seungmi; Lee, Sahnghoon; Kim, Hee Joong
2016-01-01
Background We analyzed the data for primary total hip arthroplasty (THA) in the Korean nationwide database to assess (1) the epidemiology and national trends of bearing surface usage in THAs and (2) the prevalence of each type of bearing surface according to age, gender, hospital type, primary payer, and hospital procedure volume. Methods A total of 30,881 THAs were analyzed using the Korean Health Insurance Review and Assessment Service database for 2007 through 2011. Bearing surfaces were sub-grouped according to device code for national health insurance claims and consisted of ceramic-on-ceramic (CoC), metal-on-polyethylene (MoP), ceramic-on-polyethylene (CoP), and metal-on-metal (MoM). The prevalence of each type of bearing surface was calculated and stratified by age, gender, hospital type, primary payer, and procedure volume of each hospital. Results CoC was the most frequently used bearing surface (76.7%), followed by MoP (11.9%), CoP (7.3%), and MoM (4.1%). The proportion of THAs using a CoC bearing surface increased steadily from 71.6% in 2007 to 81.4% in 2011, whereas the proportions using CoP, MoP, and MoM bearing surfaces decreased. The order of prevalence was identical to that in the general population regardless of age, gender, hospital type, primary payer, and hospital procedure volume. Conclusions The trends and epidemiology of bearing surface usage in THAs in Korea are different from those in other countries, and the CoC bearing surface is the most prevalent articulation. In future, the results of a large-scale study using nationwide data of THAs involving a CoC bearing surface will be reported in Korea. PMID:26929796
Yoon, Pil Whan; Yoo, Jeong Joon; Kim, Yunjung; Yoo, Seungmi; Lee, Sahnghoon; Kim, Hee Joong
2016-03-01
We analyzed the data for primary total hip arthroplasty (THA) in the Korean nationwide database to assess (1) the epidemiology and national trends of bearing surface usage in THAs and (2) the prevalence of each type of bearing surface according to age, gender, hospital type, primary payer, and hospital procedure volume. A total of 30,881 THAs were analyzed using the Korean Health Insurance Review and Assessment Service database for 2007 through 2011. Bearing surfaces were sub-grouped according to device code for national health insurance claims and consisted of ceramic-on-ceramic (CoC), metal-on-polyethylene (MoP), ceramic-on-polyethylene (CoP), and metal-on-metal (MoM). The prevalence of each type of bearing surface was calculated and stratified by age, gender, hospital type, primary payer, and procedure volume of each hospital. CoC was the most frequently used bearing surface (76.7%), followed by MoP (11.9%), CoP (7.3%), and MoM (4.1%). The proportion of THAs using a CoC bearing surface increased steadily from 71.6% in 2007 to 81.4% in 2011, whereas the proportions using CoP, MoP, and MoM bearing surfaces decreased. The order of prevalence was identical to that in the general population regardless of age, gender, hospital type, primary payer, and hospital procedure volume. The trends and epidemiology of bearing surface usage in THAs in Korea are different from those in other countries, and the CoC bearing surface is the most prevalent articulation. In future, the results of a large-scale study using nationwide data of THAs involving a CoC bearing surface will be reported in Korea.
Zhang, Pei; Liang, Yuan; Chen, Pengtao; Fang, Yongchao; He, Jinshan; Wang, Jingcheng
2017-02-21
The use of intravenous (IV) or topical tranexamic acid (TXA) in total hip arthroplasty has been proven to be effective and safe in total hip arthroplasty. However, which of these two administration routes is better has not been determined. The combined administration of TXA has been used in total knee arthroplasty with satisfactory results. We hypothesized that combined application of TXA may be the most effective way without increased rate of thrombotic events such as deep vein thrombosis (DVT) and pulmonary embolisms (PE) in patients subjected to primary total hip replacement (THA). A meta-analysis was conducted to compare the efficacy and safety of the combined use of tranexamic acid (TXA) relative to topical or intravenous (IV) use alone for treatment of primary THA. The outcomes included total blood loss, postoperative hemoglobin decline, transfusion rates, and the incidence rates of deep vein thrombosis (DVT) and pulmonary embolisms (PE). We searched electronic databases including PubMed, EMBASE, the Cochrane Library, Web of Science, the Chinese Biomedical Literature database, the CNKI database, and Wanfang Data until September 2016. The references of the included articles were also checked for additional potentially relevant studies. There were no language restrictions for the search. The data of the included studies were analyzed using RevMan 5.3 software. Seven studies met the inclusion criteria, encompassing a total of 1762 patients. Our meta-analysis demonstrated that total blood loss, postoperative hemoglobin decline, and transfusion rates were significantly lower for patients that received the combined treatment compared to patients that received either topical or intravenous administration of TXA. No statistical differences were found in the incidence of deep venous thrombosis (DVT) or pulmonary embolism (PE). The group that received the combined treatment had lower total blood loss, postoperative hemoglobin decline, and transfusion rates without an increased rate of thrombotic events (DVT or PE). The topical or intravenous use of TXA in primary THA is generally considered to be safe and effective. This meta-analysis demonstrated that combined TXA application may be superior to topical or intravenous application of TXA alone. However, larger, high-quality randomized control trials are required for greater confidence in this finding.
Outpatient Shoulder Arthroplasty.
Brolin, Tyler J; Throckmorton, Thomas W
2018-01-01
Health care policy makers have placed increased attention on the cost of health care making outpatient joint arthroplasty an attractive alternative to routine hospital admission. Recent studies have shown outpatient shoulder arthroplasty is a safe and cost-effective alternative to inpatient shoulder arthroplasty. Proper patient selection, patient education, effective pain management strategies, and attention to intraoperative blood loss are keys in the success of outpatient shoulder arthroplasty. Copyright © 2017 Elsevier Inc. All rights reserved.
How reverse shoulder arthroplasty works.
Walker, Matthew; Brooks, Jordan; Willis, Matthew; Frankle, Mark
2011-09-01
The reverse total shoulder arthroplasty was introduced to treat the rotator cuff-deficient shoulder. Since its introduction, an improved understanding of the biomechanics of rotator cuff deficiency and reverse shoulder arthroplasty has facilitated the development of modern reverse arthroplasty designs. We review (1) the basic biomechanical challenges associated with the rotator cuff-deficient shoulder; (2) the biomechanical rationale for newer reverse shoulder arthroplasty designs; (3) the current scientific evidence related to the function and performance of reverse shoulder arthroplasty; and (4) specific technical aspects of reverse shoulder arthroplasty. A PubMed search of the English language literature was conducted using the key words reverse shoulder arthroplasty, rotator cuff arthropathy, and biomechanics of reverse shoulder arthroplasty. Articles were excluded if the content fell outside of the biomechanics of these topics, leaving the 66 articles included in this review. Various implant design factors as well as various surgical implantation techniques affect stability of reverse shoulder arthroplasty and patient function. To understand the implications of individual design factors, one must understand the function of the normal and the cuff-deficient shoulder and coalesce this understanding with the pathology presented by each patient to choose the proper surgical technique for reconstruction. Several basic science and clinical studies improve our understanding of various design factors in reverse shoulder arthroplasty. However, much work remains to further elucidate the performance of newer designs and to evaluate patient outcomes using validated instruments such as the American Society for Elbow Surgery, simple shoulder test, and the Constant-Murley scores.
Martinelli, Nicolo; Baretta, Silvia; Pagano, Jenny; Bianchi, Alberto; Villa, Tomaso; Casaroli, Gloria; Galbusera, Fabio
2017-11-25
Mobile-bearing ankle implants with good clinical results continued to increase the popularity of total ankle arthroplasty to address endstage ankle osteoarthritis preserving joint movement. Alternative solutions used fixed-bearing designs, which increase stability and reduce the risk of bearing dislocation, but with a theoretical increase of contact stresses leading to a higher polyethylene wear. The purpose of this study was to investigate the contact stresses, pressure and area in the polyethylene component of a new total ankle replacement with a fixed-bearing design, using 3D finite element analysis. A three-dimensional finite element model of the Zimmer Trabecular Metal Total Ankle was developed and assembled based on computed tomography images. Three different sizes of the polyethylene insert were modeled, and a finite element analysis was conducted to investigate the contact pressure, the von Mises stresses and the contact area of the polyethylene component during the stance phase of the gait cycle. The peak value of pressure was found in the anterior region of the articulating surface, where it reached 19.8 MPa at 40% of the gait cycle. The average contact pressure during the stance phase was 6.9 MPa. The maximum von Mises stress of 14.1 MPa was reached at 40% of the gait cycle in the anterior section. In the central section, the maximum von Mises stress of 10.8 MPa was reached at 37% of the gait cycle, whereas in the posterior section the maximum stress of 5.4 MPa was reached at the end of the stance phase. The new fixed-bearing total ankle replacement showed a safe mechanical behavior and many clinical advantages. However, advanced models to quantitatively estimate the wear are need. To the light of the clinical advantages, we conclude that the presented prosthesis is a good alternative to the other products present in the market.
Chen, Yun-Lin; Lin, Tiao; Liu, An; Shi, Ming-Min; Hu, Bin; Shi, Zhong-Li; Yan, Shi-Gui
2015-01-28
There are some arguments between the use of hydroxyapatite and porous coating. Some studies have shown that there is no difference between these two coatings in total hip arthroplasty (THA), while several other studies have shown that hydroxyapatite has advantages over the porous one. We have collected the studies in Pubmed, MEDLINE, EMBASE, and the Cochrane library from the earliest possible years to present, with the search strategy of "(HA OR hydroxyapatite) AND ((total hip arthroplasty) OR (total hip replacement)) AND (RCT* OR randomiz* OR control* OR compar* OR trial*)". The randomized controlled trials and comparative observation trials that evaluated the clinical and radiographic effects between hydroxyapatite coating and porous coating were included. Our main outcome measurements were Harris hip score (HHS) and survival, while the secondary outcome measurements were osteolysis, radiolucent lines, and polyethylene wear. Twelve RCTs and 9 comparative observation trials were included. Hydroxyapatite coating could improve the HHS (p < 0.01), reduce the incidence of thigh pain (p = 0.01), and reduce the incidence of femoral osteolysis (p = 0.01), but hydroxyapatite coating had no advantages on survival (p = 0.32), polyethylene wear (p = 0.08), and radiolucent lines (p = 0.78). Hydroxyapatite coating has shown to have an advantage over porous coating. The HHS and survival was duration-dependent-if given the sufficient duration of follow-up, hydroxyapatite coating would be better than porous coating for the survival. The properties of hydroxyapatite and the implant design had influence on thigh pain incidence, femoral osteolysis, and polyethylene wear. Thickness of 50 to 80 μm and purity larger than 90% increased the thigh pain incidence. Anatomic design had less polyethylene wear.
Olsen, Michael; Al Saied, Mohamed; Morison, Zachary; Sellan, Michael; Waddell, James P; Schemitsch, Emil H
2014-12-01
Mid-head resection short-stem hip arthroplasty is a conservative alternative to conventional total hip replacement and addresses proximal fixation challenges in patients not suitable for hip resurfacing. It is unclear whether proximal femoral morphology impacts the ultimate failure load of mid-head resection implanted femurs, thus the aim of this study was to investigate the effect of native neck-shaft angle (NSA) and coronal implant alignment on proximal femoral strength. In total, 36 synthetic femurs with two different proximal femoral morphologies were utilized in this study. Of them, 18 femurs with a varus NSA of 120° and 18 femurs with a valgus NSA of 135° were each implanted with a mid-head resection prosthesis. Femurs within the two different femoral morphology groups were divided into three equal coronal implant alignment groups: 10° valgus, 10° varus or neutral alignment. Prepared femurs were tested for stiffness and to failure in axial compression. There was no significant difference in stiffness nor failure load between femurs implanted with valgus-, varus- or neutrally aligned implants in femurs with a NSA of 120° (p = 0.396, p = 0.111, respectively). Femurs implanted in valgus orientation were significantly stiffer and failed at significantly higher loads than those implanted in varus alignment in femurs with a NSA of 135° (p = 0.001, p = 0.007, respectively). A mid-head resection short-stem hip arthroplasty seems less sensitive to clinically relevant variations of coronal implant alignment and may be more forgiving upon implantation in some femoral morphologies, however, a relative valgus component alignment is recommended. © IMechE 2014.
Surgical waste audit of 5 total knee arthroplasties
Stall, Nathan M.; Kagoma, Yoan K.; Bondy, Jennifer N.; Naudie, Douglas
2013-01-01
Background Operating rooms (ORs) are estimated to generate up to one-third of hospital waste. At the London Health Sciences Centre, prosthetics and implants represent 17% of the institution’s ecological footprint. To investigate waste production associated with total knee arthroplasties (TKAs), we performed a surgical waste audit to gauge the environmental impact of this procedure and generate strategies to improve waste management. Methods We conducted a waste audit of 5 primary TKAs performed by a single surgeon in February 2010. Waste was categorized into 6 streams: regular solid waste, recyclable plastics, biohazard waste, laundered linens, sharps and blue sterile wrap. Volume and weight of each stream was quantified. We used Canadian Joint Replacement Registry data (2008–2009) to estimate annual weight and volume totals of waste from all TKAs performed in Canada. Results The average surgical waste (excluding laundered linens) per TKA was 13.3 kg, of which 8.6 kg (64.5%) was normal solid waste, 2.5 kg (19.2%) was biohazard waste, 1.6 kg (12.1%) was blue sterile wrap, 0.3 kg (2.2%) was recyclables and 0.3 kg (2.2%) was sharps. Plastic wrappers, disposable surgical linens and personal protective equipment contributed considerably to total waste. We estimated that landfill waste from all 47 429 TKAs performed in Canada in 2008–2009 was 407 889 kg by weight and 15 272 m3 by volume. Conclusion Total knee arthroplasties produce substantial amounts of surgical waste. Environmentally friendly surgical products and waste management strategies may allow ORs to reduce the negative impacts of waste production without compromising patient care. Level of evidence Level IV, case series. PMID:23351497
Mühlhofer, Heinrich M L; Deiss, Lukas; Mayer-Kuckuk, Philipp; Pohlig, Florian; Harrasser, Norbert; Lenze, Ulrich; Gollwitzer, Hans; Suren, Christian; Prodinger, Peter; VON Eisenhart-Rothe, Rüdiger; Schauwecker, Johannes
2017-01-01
Prosthetic joint infection (PJI) remains a major complication after total joint replacement and is the primary indication for revision arthroplasty. Specifically, coagulase-negative Staphylococci (CNS) can cause low-grade infections. Despite the use of cephalosporin-based antimicrobial prophylaxis (AMP) and antiseptic treatment at the surgical site, evidence suggests that a significant number of cases of dermal CNS results in low-grade PJI. Thus, this study examined the bacterial colonization and resistance patterns at the surgical site. We hypothesized that the bacteria developed resistance to antibiotics that are frequently used in primary and revision total hip arthroplasty (THA) procedures. Ninety patients, including 63 primary and 27 revision THA patients, were enrolled in this study. For each patient, a single swab of the skin at the surgical site was subjected to clinical microbiology to assess bacterial colonization. Furthermore, resistance to a sentinel panel of antibiotics (benzylpenicillin, erythromycin, tetracycline, oxacillin, fusidic acid, clindamycin, gentamicin, levofloxacin/moxifloxacin, rifampicin, linezolid and vancomycin) was tested. In 96.7% of the patients, at least one bacterial strain was identified at the surgical site, with CNS strains comprising 93.1% of the total. The sentinel panel showed that 30.7% of the CNS strains exhibited maximal resistance to oxacillin, a commonly used cephalosporin. Additionally, oxacillin resistance increased 1.9-fold (p=0.042) between primary and revision THA. Notably, 8.1% of the CNS stains found on patients undergoing primary THA were resistant to gentamicin, an aminoglycoside, and this rate increased 4.7-fold (p=0.001) for patients undergoing revision THA. CNS strains have significant resistance to standard AMP, particularly in individuals undergoing revision THA. Copyright© 2017, International Institute of Anticancer Research (Dr. George J. Delinasios), All rights reserved.
Anaemia in elective orthopaedic surgery - Royal Adelaide Hospital, Australia.
Kearney, B; To, J; Southam, K; Howie, D; To, B
2016-01-01
An anaemia clinic was established to improve the preoperative management of elective orthopaedic patients scheduled for arthroplasty. This paper is a report on the first 100 patients assessed. To assess the incidence and causes of anaemia in patients on a waiting list for elective arthroplasty in a public hospital and to assess the impact of anaemia detection in this patient population. Patients attending an Anaemia Clinic for elective orthopaedic surgical patients, during March 2010 to June 2013 were studied. Outcome measures included change in haemoglobin preoperative results and perioperative transfusion rates by preoperative haemoglobin. Seventeen per cent of patients scheduled for elective surgery were found to be anaemic. Of the 100 patients who attended, approximately half were found to be iron deficient and the remainder had anaemia of chronic disease. Serum ferritin <30 µg/L alone did not identify iron deficiency in 80% of patients with iron deficiency. Patients with iron deficient anaemia were able to be treated, in all cases, to achieve a significant increase in preoperative haemoglobin. The general unavailability of erythropoietin limited effective intervention for the non-iron-deficient anaemic patients. Seven patients had their surgery cancelled because of the screening programme. Half of the anaemic patients in a joint replacement screening clinic were iron deficient, and treatment was effective in improving the pre-operative haemoglobin and reducing perioperative transfusion rates. This screening process should improve patient outcome. Another important finding in this group of patients is that ferritin levels cannot be reliably used as the sole indicator in the diagnosis of iron deficiency anaemia in this group of patients undergoing elective arthroplasty. © 2015 Royal Australasian College of Physicians.
Predictors of Patient-Reported Outcomes of Total Joint Arthroplasty in a Developing Country.
Bido, Jennifer; Yang, Ying H; Collins, Jamie E; Dong, Yan; Driscoll, Daniel A; Alcantara, Luis A; Thornhill, Thomas S; Katz, Jeffrey N
2017-06-01
In response to the growing burden of joint disease, developing countries are starting to create their own total joint arthroplasty (TJA) programs. To date, there has been limited research on predictors of TJA outcomes in a developing country. This investigation uses patient-reported outcome measures collected by a medical mission to assess predictors of TJA outcomes in the Dominican Republic. Baseline and postoperative information from 156 of the mission's recipients of hip and knee TJA was used. Demographics were abstracted from clinical notes, and self-reported pain and functional status were assessed using Western Ontario and McMaster University Osteoarthritis Index and Short-Form 36 measures. Bivariate analysis identified variables to include in multivariable regression models of factors associated with function and pain outcomes and improvement in these domains 1 or 2 years postoperatively. The cohort had a mean age of 61.3 years, 82% were female, 79% had total knee arthroplasty, and 42% of the procedures were bilateral. In multivariate analyses, at P < .05, male sex, better preoperative function, and use of bilateral procedure were associated with better functional outcome. Male sex and worse preoperative pain were associated with better pain outcome. Worse preoperative pain and function, as well as bilateral surgery were associated with greater improvement in function. Additionally, a greater number of bothersome joints was associated with greater pain reduction. Our findings of better follow-up pain scores among patients with worse pain preoperatively and better functional improvement among those undergoing bilateral replacements contrast with study results from developed countries. The explanations for these observations merit further study. Copyright © 2017 Elsevier Inc. All rights reserved.
Hatch, M Daniel; Daniels, Stephen D; Glerum, Kimberly M; Higgins, Laurence D
2017-03-01
Increasing methicillin resistance and recognition of Propionibacterium acnes as a cause of infection in shoulder arthroplasty has led to the adoption of local vancomycin powder application as a more effective method to prevent expensive periprosthetic infections. However, no study has analyzed the cost effectiveness of vancomycin powder for preventing infection after shoulder replacement. Cost data for infection-related care of 16 patients treated for deep periprosthetic shoulder infection was collected from our institution for the break-even analysis. An equation was developed and applied to the data to determine how effective vancomycin powder would need to be at reducing a baseline infection rate to make prophylactic use cost effective. The efficacy of vancomycin (absolute risk reduction [ARR]) was evaluated at different unit costs, baseline infection rates, and average costs of treating infection. We determined vancomycin to be cost effective if the initial infection rate decreased by 0.04% (ARR). Using the current costs of vancomycin reported in the literature (range: $2.50/1000 mg to $44/1000 mg), we determined vancomycin to be cost effective with an ARR range of 0.01% at a cost of $2.50/1000 mg to 0.19% at $44/1000 mg. Baseline infection rate does not influence the ARR obtained at any specific cost of vancomycin or the cost of treating infection. We have derived and used a break-even equation to assess efficacy of prophylactic antibiotics during shoulder surgery. We further demonstrated the prophylactic administration of local vancomycin powder during shoulder arthroplasty to be a highly cost-effective practice. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Efficiency and cost analysis of cell saver auto transfusion system in total knee arthroplasty.
Bilgili, Mustafa Gökhan; Erçin, Ersin; Peker, Gökhan; Kural, Cemal; Başaran, Serdar Hakan; Duramaz, Altuğ; Avkan, Cevdet
2014-06-01
Blood loss and replacement is still a controversial issue in major orthopaedic surgery. Allogenic blood transfusion may cause legal problems and concerns regarding the transmission of transfusion-related diseases. Cellsaver Systems (CSS) were developed as an alternative to allogenic transfusion but CSS transfusion may cause coagulation, infection and haemodynamic instability. Our aim was to analyse the efficiency and cost analysis of a cell saver auto-transfusion system in the total knee arthroplasty procedure. Retrospective comparative study. Those patients who were operated on by unilateral, cemented total knee arthroplasty (TKA) were retrospectively evaluated. Group 1 included 37 patients who were treated using the cell saver system, and Group 2 involved 39 patients who were treated by allogenic blood transfusion. The groups were compared in terms of preoperative haemoglobin and haematocrit levels, blood loss and transfusion amount, whether allogenic transfusion was made, degree of deformity, body mass index and cost. No significant results could be obtained in the statistical comparisons made in terms of the demographic properties, deformity properties, preoperative laboratory values, transfusion amount and length of hospital stay of the groups. Average blood loss was calculated to be less in Group 1 (p<0.05) and cost was higher in Group 1 (p<0.05). Cell saver systems do not decrease the amount of allogenic blood transfusion and costs more. Therefore, the routine usage of the auto-transfusion systems is a controversial issue. Cell saver system usage does not affect allogenic blood transfusion incidence or allogenic blood transfusion volume. It was found that preoperative haemoglobin and body mass index rates may affect allogenic blood transfusion. Therefore, it is foreseen that auto-transfusion systems could be useful in patients with low haemoglobin level and body mass index.
Maccioni, Cristobal B; Woodbridge, Adam B; Balestro, Jean-Christian Y; Figtree, Melanie C; Hudson, Bernard J; Cass, Benjamin; Young, Allan A
2015-08-01
Propionibacterium acnes is a recognized pathogen in postoperative shoulder infections. A recent study reported growth of P acnes in 42% of glenohumeral joints in primary shoulder arthroplasty, concluding that P acnes may cause shoulder osteoarthritis. Whether these results reflect true bacterial infection or specimen contamination is unclear. Our prospective study aimed to determine the rate of P acnes infection in arthritic shoulders using a strict specimen collection technique. We used modified Oxford protocol to collect tissue specimens from the glenohumeral joint of 32 consecutive patients undergoing primary shoulder arthroplasty. Specimens were cultured specifically for P acnes. Diagnosis of P acnes infection required 2 or more positive cultures and histopathology compatible with infection. Three of 32 patients had a positive culture for P acnes. Overall, 3.125% of specimens grew P acnes without histologic evidence of infection. There were no patients with P acnes infection. The difference in culture rates between patients with idiopathic osteoarthritis and those with a predisposing cause for osteoarthritis was not significant. We found a low rate of positive cultures for P acnes, but no P acnes infection and no difference between types of osteoarthritis. These results do not support a cause-and-effect relationship between P acnes and osteoarthritis. The differing results from previous studies are likely explained by our strict specimen collection technique, reflecting different rates of contamination rather than infection. That P acnes contamination occurs in primary shoulder arthroplasty is concerning. Further studies are needed to assess the rates of contamination in shoulder surgery, its clinical effect, and to determine optimal antibiotic prophylaxis. Crown Copyright © 2015. Published by Elsevier Inc. All rights reserved.
Liu, Joseph N; Garcia, Grant H; Mahony, Gregory; Wu, Hao-Hua; Dines, David M; Warren, Russell F; Gulotta, Lawrence V
2016-06-01
Traditionally, fewer postoperative sport restrictions are imposed on hemiarthroplasty (HHA) patients on than reverse total shoulder arthroplasty (RTSA) patients. However, functional outcomes have been shown to be superior in RTSA. No direct comparison of RTSA vs HHA has been done on rates of return to sports in patients with glenohumeral arthritis and rotator cuff dysfunction, proximal humeral fractures, or rheumatoid arthritis. This is a retrospective review of consecutive RTSA and HHA patients collected from our institution's shoulder arthroplasty registry. All patients playing sports preoperatively with minimum 1-year follow-up were included. Final follow-up included an additional patient-reported questionnaire with questions regarding physical fitness and sport activities. The study included 102 RTSA and 71 HHA patients. Average age at surgery was 72.3 years for RTSA compared with 65.6 years for HHA (P < .001). Patients undergoing RTSA had improved visual analog scale scores compared with HHA (-5.6 vs -4.2, P = .007), returned to sports after RTSA at a significantly higher rate (85.9% vs 66.7%, P = .02), and were more likely to be satisfied with their ability to play sports (P = .013). HHA patients were also more likely to have postoperative complaints than RTSA patients (63% vs 29%, P < .0001). No sports-related complications occurred. Female sex, age <70 years, surgery on the dominant extremity, and a preoperative diagnosis of arthritis with rotator cuff dysfunction predicted a higher likelihood of return to sports for patients undergoing RTSA compared with HHA. Despite traditional sport restrictions placed on RTSA, patients undergoing RTSA can return to sports at rates higher than those undergoing HHA, with fewer postoperative complaints. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Cost analysis of debridement and retention for management of prosthetic joint infection.
Peel, T N; Dowsey, M M; Buising, K L; Liew, D; Choong, P F M
2013-02-01
Prosthetic joint infection remains one of the most devastating complications of arthroplasty. Debridement and retention of the prosthesis is an attractive management option in carefully selected patients. Despite this, there are no data investigating the cost of this management modality for prosthetic joint infections. The aim of this case-control study was to calculate the cost associated with debridement and retention for management of prosthetic joint infection compared with primary joint replacement surgery without prosthetic joint infection. From 1 January 2008 to 30 June 2010, there were 21 prosthetic joint infections matched to 42 control patients. Controls were matched to cases according to the arthroplasty site, age and sex. Cases had a greater number of unplanned readmissions (100% vs. 7.1%; p <0.001), more additional surgery (3.3 vs. 0.07; p <0.001) and longer total bed days (31.6 vs. 7.9 days; p <0.001). In addition they had more inpatient, outpatient and emergency department visits (p <0.001, respectively). For patients with prosthetic joint infection the total cost, including index operation and costs of management of the prosthetic joint infection, was 3.1 times the cost of primary arthoplasty; the mean cost for cases was Australian dollars (AUD) $69,414 (±29,869) compared with $22,085 (±8147) (p <0.001). The demand for arthroplasty continues to grow and with that, the number of prosthetic joint infections will also increase, placing significant burden on the health system. Our study adds significantly to the growing body of evidence highlighting the substantial costs associated with prosthetic joint infection. © 2011 The Authors. Clinical Microbiology and Infection © 2011 European Society of Clinical Microbiology and Infectious Diseases.
Leta, Tesfaye H; Lygre, Stein Håkon L; Skredderstuen, Arne; Hallan, Geir; Gjertsen, Jan-Erik; Rokne, Berit; Furnes, Ove
2016-04-01
In Norway, 19 % of revisions of non-resurfaced total knee arthroplasties done for knee pain between 1994 and 2011 were Secondary Patella Resurfacing (SPR). It is, however, unclear whether SPR actually resolves the pain. The aim was to investigate prostheses survival and clinical outcomes following SPR. A total of 308 knees (301 patients) with SPR were used to assess implant survival, and a sub-cohort (n = 114 out of 301 patients) with Patient Reported Outcome Measures (PROMs) data were used to assess the clinical outcomes. The EuroQol (EQ-5D), the Knee Injury and Osteoarthritis Outcome Score, and Visual Analogue Scales on satisfaction and pain were used to collect PROM data. Outcomes were analysed by Kaplan-Meier, Cox regression, and multiple linear regression. The five- and ten-year Kaplan-Meier survival percentages were 91 % and 87 %, respectively. Overall, 35 knees were re-revised at a median follow-up of eight years and pain alone (10 knees) was the main cause of re-revision. Younger patients (<60 years) had nearly nine times higher risk of re-revision compared to older patients (>70 years) (RR = 8.6; p < 0.001). Mean EQ-5D index score had improved from 0.41 (SD 0.21) preoperative to 0.56 (SD 0.25) postoperative following SPR. A total of 63 % of patients with PROM data were satisfied with the outcomes of SPR. The long-term prostheses survival following SPR was satisfactory, although not as good as for primary knee replacement. Patients' health related quality of life improved significantly following SPR. Still, more than a third of patients with PROMs data were dissatisfied with the outcomes of the SPR procedure.
ON-Q infusion pump linked to increased hospital stay after total knee arthroplasty.
O'Neil, Stephen; Danielson, Kristopher; Johnson, Kory; Matelic, Thomas
2018-06-01
The purpose of this study was to evaluate immediate postoperative pain control modalities after total knee arthroplasty at the author's specific institution and compare those modalities with patient satisfaction, rehabilitation status, and length of hospital stay. A retrospective chart review of 101 patients who underwent total knee arthroplasty from 2013 to 2016 was performed. Data was collected including the pain control modality, total pain medication consumption, physical therapy progress, length of hospital stay and Visual Analog Scores. Analysis was then performed using SAS proprietary software. Results were reported as statistically significant if p value was less than 0.05. Multiple variables proved to be statistically significant (p value <0.05) in this particular study. Patients who received Valium required more morphine equivalents on average and reported higher Visual Analog Scores (VAS). For those patients who received a lower extremity nerve block pre operatively, there was a decrease in morphine equivalents on postoperative day one and lower VAS. For those patients who received the continuous pain pump, ON-Q postoperatively, there was an average increase in length of hospital stay by one day and a decrease in ambulation on postoperative day one. Also, females required less overall pain medication on postoperative days two and three compared to their male counterparts. Finally, there was no statistically significant difference for those patients who received Lyrica (pregabalin) or NSAIDS for the parameters that were measured in this study. Postoperative pain control modalities after total knee arthroplasty are highly variable among physicians. This variability has allowed researchers to review each modality and compare and contrast the benefits with the potential adverse effects of these medications on total knee replacement outcomes. The data in this study suggests that the use of Valium is correlated with increased pain medication consumption and decreased patient satisfaction. Data from this study also reveals that patients who underwent preoperative nerve blocks experienced decreased pain on postoperative day one and greater patient satisfaction. The most notable contribution of this study was the discovery of the adverse effects of the continuous pain pump, ON-Q. Patients treated with this modality had decreased ambulation on postoperative day one and on average remained in the hospital one extra day, a variable that significantly increases the cost of a total knee arthroplasty for the hospital, the surgeon and the patient. Even though this data is significant, further studies should be performed to enhance our knowledge of postoperative pain control for these patients.
Restrepo, Camilo; Post, Zachary D; Kai, Brandon; Hozack, William J
2010-03-01
The ceramic-on-ceramic bearing for total hip arthroplasty has an extremely low wear rate and demonstrates minimal inflammatory response in comparison with other bearing choices. However, acoustic emissions such as squeaking and clicking are being reported as annoying complications related to its use. The cause or causes of this phenomenon have not been determined. The purpose of the present study was to evaluate the possibility that design aspects of the femoral component may be a contributing factor to the etiology of squeaking associated with the ceramic-on-ceramic bearing total hip arthroplasty. We retrospectively reviewed 266 consecutive patients (304 hips) who had undergone total hip arthroplasty with use of ceramic-on-ceramic bearings. The first 131 consecutive patients (152 hips) (Group 1) received a hydroxyapatite-coated stem composed of titanium-aluminum-vanadium alloy with a C-taper neck geometry and robust midsection with an anteroposterior diameter of 13 mm. The second 135 consecutive patients (152 hips) (Group 2) also received a hydroxyapatite-coated stem, but in that group the stem was composed of titanium-molybdenum-zirconium-iron alloy, with a V-40 neck geometry and a midsection with an anteroposterior thickness of only 10 mm. All 304 hips received the same cup, composed of titanium-aluminum-vanadium alloy. Demographic characteristics, such as age, sex, height, weight, and body mass index, were similar in both groups. Data regarding the presence of squeaking were obtained prospectively. Patients who were seen for clinical follow-up either expressed the squeaking phenomenon themselves or were asked about it by the physician. Patients who were not seen at a recent clinical follow-up visit were contacted by telephone and were asked specifically about squeaking that might be associated with the hip replacement. Only patients with confirmed squeaking noise were included in the present study. Postoperative radiographs, the Short Form-36 health survey, the Harris hip score, and office or telephone interviews of the patient were used to determine the overall outcome of the procedure. The prevalence of squeaking was seven times higher for patients who received the titanium-molybdenum-zirconium-iron-alloy stem (twenty-seven patients, twenty-eight hips [18.4%]) than in those who received the titanium-aluminum-vanadium-alloy stem (three patients, four hips [2.6%]); this difference was significant (p < 0.0001). Our study suggests that different stem alloys, stem geometries, or neck geometries can have an impact on the frequency of squeaking following a ceramic-on-ceramic total hip arthroplasty.
Hellevik, Alf Inge; Johnsen, Marianne Bakke; Langhammer, Arnulf; Baste, Valborg; Furnes, Ove; Storheim, Kjersti; Zwart, John Anker; Flugsrud, Gunnar Birkeland; Nordsletten, Lars
2018-01-01
Objective Biochemical changes associated with obesity may accelerate osteoarthritis beyond the effect of mechanical factors. This study investigated whether metabolic syndrome and its components (visceral obesity, hypertension, dyslipidemia and insulin resistance) were risk factors for subsequent total hip replacement (THR) or total knee replacement (TKR) due to primary osteoarthritis. Design In this prospective cohort study, data from the second survey of the Nord-Trøndelag Health Study 2 (HUNT2) were linked to the Norwegian Arthroplasty Register for identification of the outcome of THR or TKR. The analyses were stratified by age (<50, 50–69.9 and ≥70 years) and adjusted for gender, body mass index, smoking, physical activity and education. Results Of the 62,661 participants, 12,593 (20.1%) were identified as having metabolic syndrome, and we recorded 1,840 (2.9%) THRs and 1,111 (1.8%) TKRs during a mean follow-up time of 15.4 years. Cox regression analyses did not show any association between full metabolic syndrome and THR or TKR, except in persons <50 years with metabolic syndrome who had a decreased risk of THR (hazard ratio [HR] 0.58, 95% CI 0.40–0.83). However, when including only participants whose exposure status did not change during follow-up, this protective association was no longer significant. Increased waist circumference was associated with increased risk of TKR in participants <50 years (HR 1.62, 95% CI 1.10–2.39) and 50–69.9 years (HR 1.43, 95% CI 1.14–1.80). Hypertension significantly increased the risk of TKR in participants <50 years (HR 1.38, 95% CI 1.05–1.81), and this risk was greater for men. Conclusion This study found an increased risk of TKR in men <50 years with hypertension and persons <70 years with increased waist circumference. Apart from this, neither metabolic syndrome nor its components were associated with increased risk of THR or TKR due to primary osteoarthritis. PMID:29391831
Hellevik, Alf Inge; Johnsen, Marianne Bakke; Langhammer, Arnulf; Baste, Valborg; Furnes, Ove; Storheim, Kjersti; Zwart, John Anker; Flugsrud, Gunnar Birkeland; Nordsletten, Lars
2018-01-01
Biochemical changes associated with obesity may accelerate osteoarthritis beyond the effect of mechanical factors. This study investigated whether metabolic syndrome and its components (visceral obesity, hypertension, dyslipidemia and insulin resistance) were risk factors for subsequent total hip replacement (THR) or total knee replacement (TKR) due to primary osteoarthritis. In this prospective cohort study, data from the second survey of the Nord-Trøndelag Health Study 2 (HUNT2) were linked to the Norwegian Arthroplasty Register for identification of the outcome of THR or TKR. The analyses were stratified by age (<50, 50-69.9 and ≥70 years) and adjusted for gender, body mass index, smoking, physical activity and education. Of the 62,661 participants, 12,593 (20.1%) were identified as having metabolic syndrome, and we recorded 1,840 (2.9%) THRs and 1,111 (1.8%) TKRs during a mean follow-up time of 15.4 years. Cox regression analyses did not show any association between full metabolic syndrome and THR or TKR, except in persons <50 years with metabolic syndrome who had a decreased risk of THR (hazard ratio [HR] 0.58, 95% CI 0.40-0.83). However, when including only participants whose exposure status did not change during follow-up, this protective association was no longer significant. Increased waist circumference was associated with increased risk of TKR in participants <50 years (HR 1.62, 95% CI 1.10-2.39) and 50-69.9 years (HR 1.43, 95% CI 1.14-1.80). Hypertension significantly increased the risk of TKR in participants <50 years (HR 1.38, 95% CI 1.05-1.81), and this risk was greater for men. This study found an increased risk of TKR in men <50 years with hypertension and persons <70 years with increased waist circumference. Apart from this, neither metabolic syndrome nor its components were associated with increased risk of THR or TKR due to primary osteoarthritis.
Utilization rates of knee-arthroplasty in OECD countries.
Pabinger, C; Lothaller, H; Geissler, A
2015-10-01
The number of knee arthroplasties and the prevalence of obesity are increasing exponentially. To date there have been no published reviews on utilization rates of knee arthroplasty in OECD countries. We analysed economic, medical and population data relating to knee arthroplasty surgeries performed in OECD countries. Gross domestic product (GDP), health expenditures, obesity prevalence, knee arthroplasty utilization rates and growth in knee arthroplasty rates per 100,000 population were assessed for total population, for patients aged 65 years and over, and patients aged 64 years and younger. Obesity prevalence and utilization of knee arthroplasty have increased significantly in the past. The mean utilization rate of knee arthroplasty was 150 (22-235) cases per 100,000 total population in 2011. The strongest annual increase (7%) occurred in patients 64 years and under. Differences between individual countries can be explained by economic and medical patterns, with countries with higher medical expenditures and obesity prevalence having significantly higher utilization rates. Countries with lower utilization rates have significantly higher growth in utilization rates. The future demand for knee prostheses will increase x-fold by 2030, with exact rates dependant upon economic, social and medical factors. We observed a 10-fold variation in the utilization of knee arthroplasty among OECD countries. A significant and strong correlation of GDP, health expenditures and obesity prevalence with utilization of knee arthroplasty was found. Patients aged 64 years and younger show a two-fold higher growth rate in knee arthroplasty compared to the older population. This trend could result in a four-fold demand for knee arthroplasty in OECD countries by 2030. Copyright © 2015 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.
Reducing gender disparities in post-total knee arthroplasty expectations through a decision aid.
Volkmann, Elizabeth R; FitzGerald, John D
2015-02-07
Gender disparities in total knee arthroplasty utilization may be due to differences in perceptions and expectations about total knee arthroplasty outcomes. This study evaluates the impact of a decision aid on perceptions about total knee arthroplasty and decision-making parameters among patients with knee osteoarthritis. Patients with moderate to severe knee osteoarthritis viewed a video about knee osteoarthritis treatments options, including total knee arthroplasty, and received a personalized arthritis report. An adapted version of the Western Ontario and McMaster Universities Osteoarthritis Index was used to assess pain and physical function expectations following total knee arthroplasty before/after the intervention. These scores were compared to an age- and gender-adjusted means for a cohort of patients who had undergone total knee arthroplasty. Decision readiness and conflict were also measured. At baseline, both men and women had poorer expectations about post-operative pain and physical outcomes compared with observed outcomes of the comparator group. Following the intervention, women's mean age-adjusted expectations about post- total knee arthroplasty pain outcomes improved (Pre: 27.0; Post: 21.8 [p =0.08; 95% CI -0.7, 11.0]) and were closer to observed post-TKA outcomes; whereas men did not have a significant change in their pain expectations (Pre: 21.3; Post: 19.6 [p = 0.6; 95% CI -5.8, 9.4]). Women also demonstrated a significant improvement in decision readiness; whereas men did not. Both genders had less decision conflict after the intervention. Both women and men with osteoarthritis had poor estimates of total knee arthroplasty outcomes. Women responded to the intervention with more accurate total knee arthroplasty outcome expectations and greater decision readiness. Improving patient knowledge of total knee arthroplasty through a decision aid may improve medical decision-making and reduce gender disparities in total knee arthroplasty utilization.
L Riddle, Daniel; J Golladay, Gregory
2016-11-01
we determined the yearly prevalence of single and multiple falls in persons with or at risk of knee osteoarthritis (OA) and persons undergoing knee arthroplasty over an 8-year period. We also compared annual fall rates among persons with and without knee arthroplasty to determine if fall rates are associated with knee arthroplasty. we studied 4,200 persons from the Osteoarthritis Imitative (OAI), a National Institutes of Health funded prospective study of persons 45-79 years and conducted from 2004 to 2012. All either had knee OA or were at risk of developing knee OA but did not have knee arthroplasty. The surgical group comprised 413 persons who underwent knee arthroplasty. Key fall risk factors were assessed at yearly study visits. Graphical depictions illustrated single and multiple fall trajectories. Multinomial regression adjusted for potential confounders compared fall rates for those with and without knee arthroplasty. fall rate trajectories for the two samples were generally flat and fall rates were similar. For the arthroplasty sample, fall rates did not increase in the immediate perioperative period relative to earlier and later periods. No differences in fall rates were found among the arthroplasty and non-arthroplasty samples after adjustment for potential confounding (P > 0.05). fall rates were generally stable and similar over an 8-year period among persons with and without knee arthroplasty. Clinicians should not assume that persons undergoing knee arthroplasty are at greater risk for falls either before or after surgery as compared to persons with or at risk for knee OA. © The Author 2016. Published by Oxford University Press on behalf of the British Geriatrics Society. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Lendrum, J.
1980-01-01
Alternatives to conventional skin flap cover for limb wounds extend both the number and type of defects which can now be closed with reconstruction of both form and function for patients who might otherwise come to amputation. The old adage that where a sinus leads to dead or foreign material it can only be closed after removal of that dead or foreign material is no longer true. The number of patients coming to above-knee amputation after prosthetic replacement of the knee joint could be reduced by muscle flap cover of exposed arthroplasty prostheses. Images Fig. 1 Fig. 2 Fig. 3 Fig. 4 Fig. 5 Fig. 6 PMID:7377695
Grivas, Theodoros B; Savvidou, Olga D; Psarakis, Spyridon A; Bernard, Pierre-Francois; Triantafyllopoulos, George; Kovanis, Ioannis; Alexandropoulos, Panagiotis
2007-01-01
Introduction Fractures of the neck of the femoral component have been reported in uncemented total hip replacements, however, to our knowledge, no fractures of the neck of a cementless forged titanium alloy femoral stem coated in the proximal third with hydroxy-apatite have been reported in the medical literature. Case presentation This case report describes a fracture of the neck of a cementless forged titanium alloy stem coated in the proximal third with hydroxy-apatite. Conclusion The neck of the femoral stem failed from fatigue probably because of a combination of factors described analytically below. PMID:18062807
Infection burden for hip and knee arthroplasty in the United States.
Kurtz, Steven M; Lau, Edmund; Schmier, Jordana; Ong, Kevin L; Zhao, Ke; Parvizi, Javad
2008-10-01
We quantified the current and historical incidence of periprosthetic infection associated with hip and knee arthroplasty in the United States using the Nationwide Inpatient Sample, as well as corresponding hospitalization charges and length of stay. The rate of infected knee arthroplasties was 0.92%, significantly greater than that of infected hip arthroplasties with 0.88%. Length of stay was significantly longer for infected hip (9.7 days) and knee (7.6 days) arthroplasties compared to uninfected procedures (hip, 4.3 days; knee, 3.9 days) (P < .0001). Hospitalization charges were also significantly greater for infected joint arthroplasties than for uninfected arthroplasties (hips, 1.76 times; knees, 1.52 times) (P < .0001). Urban-non-teaching hospitals experienced the highest burden of infection with 1.18% for hips and 1.26% for knees compared to rural (0.61% for hips and 0.69% for knees) and urban-teaching hospitals (0.73% for hips and 0.77% for knees). We found an increasing number of joint arthroplasties being diagnosed with periprosthetic infection.
Jaiswal, Rohit; Busse, Brittany; Allen, Robert; Sahar, David
2015-05-01
Osteomyelitis of the elbow may be a complex clinical problem. Treatment goals include the eradication of infection and preservation of maximal joint function. Bony debridement may be necessary in addition to elbow joint arthroplasty. The use of synthetic material or allograft as the arthroplasty material may be contraindicated in the setting of infection. The use of free muscle transfer as an arthroplasty medium has not been well described. A 22-year-old paraplegic man developed recurrent osteomyelitis of the right elbow, necessitating extensive bony debridement by the orthopedic surgery team. Reconstruction arthroplasty was performed using a free rectus abdominis muscle flap as the arthroplasty material to serve as a source of biologically active, well-vascularized arthroplasty medium in the presence of ongoing infection. A successful free muscle flap arthroplasty was performed. External fixation and physical therapy were implemented postoperatively. The patient had resolution of osteomyelitis and excellent functional use of the elbow for activities of daily living and wheelchair motion. Elbow arthroplasty in the setting of active infection may be accomplished by means of free tissue muscle transfer. Elimination of infection and acceptable joint function may be possible with this form of reconstruction.
Lass, R; Grübl, A; Kolb, A; Domayer, S; Csuk, C; Kubista, B; Giurea, A; Windhager, R
2014-03-05
Second-generation, metal-on-metal bearings were introduced in 1988, to reduce wear and avoid polyethylene particle-induced osteolysis from total hip arthroplasty. In 2007, we reported the long-term results of ninety-eight patients (105 hips) who underwent primary cementless total hip arthroplasty involving the use of a prosthesis with a high-carbide-concentration, metal-on-metal articulating surface between November 1992 and May 1994. The present study gives an update on this patient cohort. At a minimum of seventeen years postoperatively, forty-nine patients (fifty-two hips) were available for follow-up examination. We retrospectively evaluated clinical and radiographic results as well as serum metal concentration. The mean patient age at the time of the index arthroplasty was fifty-six years. Three cups (6% of the hips) and one stem (2% of the hips) were revised because of aseptic loosening of the implants combined with focal osteolysis. At the time of the latest follow-up evaluation, the mean Harris hip score was 88.8 points, and the mean University of California Los Angeles (UCLA) activity score was 6.7 points. The cumulative rate of implant survival, with aseptic failure as the end point, was 93.0% at 18.8 years. The median serum cobalt concentration in patients whose hip implant was the only source of cobalt was 0.70 μg/L (range, 0.4 to 5.1 μg/L), showing no increase in the value as noted at a minimum of ten years of follow-up. The clinical and radiographic results of our study, which, to our knowledge, represent the longest duration of follow-up for a series of cementless total hip arthroplasties with use of a 28-mm metal-on-metal bearing, continue to be comparable with the results observed for other hard-on-hard bearings.
Holschen, M; Franetzki, B; Witt, K-A; Liem, D; Steinbeck, J
2017-08-01
Is reverse total shoulder arthroplasty a feasible treatment option for failed shoulder arthroplasty? A retrospective study of 44 cases with special regards to stemless and stemmed primary implants. Due to humeral or glenoid bone-loss and rotator cuff insufficiency reverse total shoulder arthroplasty often means the only remaining treatment option in revision shoulder arthroplasty. This study investigates the clinical outcome of patients treated with a reverse total shoulder in revision cases with special regard to stemless and stemmed primary implants. From 2010 to 2012 60 failed shoulder arthroplasties were converted to reverse total shoulder arthroplasty. Forty-four patients were available for follow-up after a mean of 24 months. Patients were assessed with X-rays, Constant- and ASES Score and a questionnaire about their subjective satisfaction. The total number of observed complications was seven (16%). Ninety-eight percent of the patients were satisfied with their clinical result. Patients achieved a mean normalized constant score of 70.2% and a mean ASES Score of 65.3. Patients with stemless primary implants achieved a higher normalized constant score than patients with stemmed primary implants (82 vs. 61.8%; p = 0009). Reverse total shoulder arthroplasty provides satisfactory clinical results and a high patient satisfaction in revision shoulder arthroplasty. The complication rate needs to be considered and discussed with the patient prior to surgery. Presence or absence of a stem of revised shoulder arthroplasties interferes with the outcome. LEVEL OF EVIDENCE IV: (Retrospective study).
Manning, William A; Ghosh, Kanishka M; Blain, Alasdair P; Longstaff, Lee M; Rushton, Steven P; Deehan, David J
2017-06-01
Tibial component rotation at time of knee arthroplasty can influence conformity, load transmission across the polyethylene surface, and perhaps ultimately determined survivorship. Optimal tibial component rotation on the cut surface is reliant on standard per operative manual stressing. This subjective assessment aims to balance constraint and stability of the articulation through a full arc of movement. Using a cadaveric model, computer navigation and under defined, previously validated loaded conditions mimicking the in vivo setting, the influence of maximal tibial component external rotation compared with the neutral state was examined for changes in laxity and tibiofemoral continuous load using 3D displacement measurement and an orthosensor continuous load sensor implanted within the polyethylene spacer in a simulated single radius total knee arthroplasty. No significant difference was found throughout arc of motion (0-115 degrees of flexion) for maximal varus and/or valgus or rotatory laxity between the 2 states. The neutral state achieved equivalence for mediolateral load distribution at each point of flexion. We have found that external rotation of the tibial component increased medial compartment load in comparison with the neutral position. Compared with the neutral state, external rotation consistently effected a marginal, but not significant reduction in lateral load under similar loading conditions. The effects were most pronounced in midflexion. On the basis of these findings, we would advocate for the midtibial tubercle point to determine tibial component rotation and caution against component external rotation. Copyright © 2017 Elsevier Inc. All rights reserved.
Orbach-Zinger, Sharon; Lenchinsky, Artium; Paul-Kesslin, Lesley; Velks, Steven; Salai, Moses; Eidelman, Leonid A
2009-01-01
BACKGROUND: Nitroglycerin (NTG) has been shown to be a useful adjunct for pain treatment without increasing adverse side effects. The effects of NTG on postoperative morphine consumption after knee replacement were evaluated. METHODS: After undergoing total knee replacement, patients receiving patient-controlled morphine analgesia were randomly assigned to receive either an NTG or a placebo patch. The blinded investigator assessed each patient using a visual analogue scale at rest and while moving, as well as the patient’s morphine requirements, sedation score, sleep quality, nausea and vomiting, vital signs and postoperative bleeding. RESULTS: Two of the patients in the NTG group suffered postoperative myocardial infarctions after removal of the patch. Because of these two serious adverse effects, the study was stopped prematurely. In the subset of patients studied, NTG conferred no advantage over placebo in pain control (visual analogue scale at rest or during movement) and in satisfaction scores. CONCLUSIONS: The use of NTG patches conferred no advantage over the use of placebo in patients receiving patient-controlled morphine analgesia after total knee replacement. Two myocardial infarcts occurred in this group. Therefore, the safety of postoperative NTG patch use for pain control must be questioned. PMID:19532851
Moran, M.; Khan, A.; Sochart, D. H.; Andrew, G.
2003-01-01
A cross-sectional study of 100 surgeons and 370 patients awaiting primary total hip or knee replacement was carried out. Oxford hip or knee score questionnaires were sent to the surgeons and patients. They were asked to predict the level of symptoms expected 6 months following surgery. The Oxford scores derive a value of 12-60, with a greater score indicating worsening symptoms. The mean pre-operative score was 45.12 for the hip patients and 42.96 for the knee patients, and the patients expected this to drop to 23.70 and 25.66, respectively, 6 months' postoperatively. This was a significant difference for both groups. The surgeons expected the patients to have a mean postoperative score of 20.91 for the hip group and 22.19 for the knee group. The surgeons' scores were significantly lower than those from the patients. There was a significant difference between the patients' and surgeons' expectations of the results of total knee and hip replacement surgery. The surgeons expected better results than the patients. We believe that this is the first study that directly compares surgeon and patient expectations of lower limb arthroplasty. PMID:12831497
Rahmann, Ann E; Brauer, Sandra G; Nitz, Jennifer C
2009-05-01
To evaluate the effect of inpatient aquatic physiotherapy in addition to usual ward physiotherapy on the recovery of strength, function, and gait speed after total hip or knee replacement surgery. Pragmatic randomized controlled trial with blinded 6-month follow-up. Acute-care private hospital. People (n=65) undergoing primary hip or knee arthroplasty (average age, 69.6+/-8.2y; 30 men). Participants were randomly assigned to receive supplementary inpatient physiotherapy, beginning on day 4: aquatic physiotherapy, nonspecific water exercise, or additional ward physiotherapy. Strength, gait speed, and functional ability at day 14. At day 14, hip abductor strength was significantly greater after aquatic physiotherapy intervention than additional ward treatment (P=.001) or water exercise (P=.011). No other outcome measures were significantly different at any time point in the trial, but relative differences favored the aquatic physiotherapy intervention at day 14. No adverse events occurred with early aquatic intervention. A specific inpatient aquatic physiotherapy program has a positive effect on early recovery of hip strength after joint replacement surgery. Further studies are required to confirm these findings. Our research indicates that aquatic physiotherapy can be safely considered in this early postoperative phase.
Reduced Operating Time but Not Blood Loss With Cruciate Retaining Total Knee Arthroplasty
Vermesan, Dinu; Trocan, Ilie; Prejbeanu, Radu; Poenaru, Dan V; Haragus, Horia; Gratian, Damian; Marrelli, Massimo; Inchingolo, Francesco; Caprio, Monica; Cagiano, Raffaele; Tatullo, Marco
2015-01-01
Background There is no consensus regarding the use of retaining or replacing cruciate implants for patients with limited deformity who undergo a total knee replacement. Scope of this paper is to evaluate whether a cruciate sparing total knee replacement could have a reduced operating time compared to a posterior stabilized implant. Methods For this purpose, we performed a randomized study on 50 subjects. All procedures were performed by a single surgeon in the same conditions to minimize bias and only knees with a less than 20 varus deviation and/or maximum 15° fixed flexion contracture were included. Results Surgery time was significantly shorter with the cruciate retaining implant (P = 0.0037). The mean duration for the Vanguard implant was 68.9 (14.7) and for the NexGen II Legacy was 80.2 (11.3). A higher range of motion, but no significant Knee Society Scores at 6 months follow-up, was used as controls. Conclusions In conclusion, both implants had the potential to assure great outcomes. However, if a decision has to be made, choosing a cruciate retaining procedure could significantly reduce the surgical time. When performed under tourniquet, this gain does not lead to reduced blood loss. PMID:25584102
[Post-anesthetic autologous blood donation used in knee and hip arthroplasty].
Wei, Wei; Kou, Bolong; Ju, Rongseng
2006-06-01
To explore the clinical application of the postanesthetic autologous donation and the postoperative transfusion during the knee and hip replacement surgeries. Thirty-three patients (17 males, 16 females) admitted for the elective joint replacement surgeries from September 2004 to January 2005 were included in this study. Of the 33 patients, 5 were diagnosed with rheumatoid arthritis, 23 with femoral head necrosis, and 5 with knee osteoarthritis. Immediately after anesthesia, 400 ml of the blood was drawn and transfused after the surgery. The blood pressure was monitored during the blood drawing, postoperative blood parameters were recorded, surgical site drainage and signs of infections were observed, and the other clinical data were collected. Of the 33 patients, 27 only received autologous transfusion, including 21 patients who underwent the unilateral hip replacement and 6 patients who underwent the unilateral knee replacement. All these 6 patients with the unilateral knee replacement received the blood drained from the surgical sites in addition to the blood obtained from the post-anesthetic autologous donation. Another 6 cases with the bilateral hip and knee replacement received the blood drained from the surgical sites, the blood obtained from the post-anesthetic autologous donation and 400 ml of the allogeneic blood transfusion. The blood received postoperatively averaged 650 ml (range, 200-1 150 ml), haemoglobin (Hb) was averaged 88 g/L (68-102 g/L), and Hct was averaged 24.6% (20.5%-31.5%). Hb and Hct were lower after operation than before operation (P < 0.01). Postoperative blood transfusion following the postanesthetic and preoperative autologous donation can be successfully applied to most of the patients undergoing the knee or hip replacement so as to reduce complications of the allogeneic blood transfusion.
Total or Partial Knee Arthroplasty Trial - TOPKAT: study protocol for a randomised controlled trial
2013-01-01
Background In the majority of patients with osteoarthritis of the knee the disease originates in the medial compartment. There are two fundamentally different approaches to knee replacement for patients with unicompartmental disease: some surgeons feel that it is always best to replace both the knee compartments with a total knee replacement (TKR); whereas others feel it is best to replace just the damaged component of the knee using a partial or unicompartment replacement (UKR). Both interventions are established and well-documented procedures. Little evidence exists to prove the clinical and cost-effectiveness of either management option. This provides an explanation for the high variation in treatment of choice by individual surgeons for the same knee pathology. The aim of the TOPKAT study will be to assess the clinical and cost effectiveness of TKRs compared to UKRs in patients with medial compartment osteoarthritis. Methods/Design The design of the study is a single layer multicentre superiority type randomised controlled trial of unilateral knee replacement patients. Blinding will not be possible as the surgical scars for each procedure differ. We aim to recruit 500 patients from approximately 28 secondary care orthopaedic units from across the UK including district general and teaching hospitals. Participants will be randomised to either UKR or TKR. Randomisation will occur using a web-based randomisation system. The study is pragmatic in terms of implant selection for the knee replacement operation. Participants will be followed up for 5 years. The primary outcome is the Oxford Knee Score, which will be collected via questionnaires at 2 months, 1 year and then annually to 5 years. Secondary outcomes will include cost-effectiveness, patient satisfaction and complications data. Trial registration Current Controlled Trials ISRCTN03013488; ClinicalTrials.gov Identifier: NCT01352247 PMID:24028414
Predictors of perioperative blood loss in total joint arthroplasty.
Park, Jai Hyung; Rasouli, Mohammad R; Mortazavi, S M Javad; Tokarski, Anthony T; Maltenfort, Mitchell G; Parvizi, Javad
2013-10-02
UPDATE The print version of this article has errors that have been corrected in the online version of this article. In the Materials and Methods section, the sentence that reads as "During the study period, our institution offered preoperative autologous blood donation to all patients who were scheduling for total joint arthroplasty with a hemoglobin level of no less than 11 mg/dL or a hematocrit level of at least 33%." in the print version now reads as "During the study period, our institution offered preoperative autologous blood donation to all patients who were scheduling for total joint arthroplasty with a hemoglobin level of no less than 11 g/dL or a hematocrit level of at least 33%." in the online version. In Table III, the footnote that reads as "The values are given as the estimate and the standard error in milligrams per deciliter." in the print version now reads as "The values are given as the estimate and the standard error in grams per deciliter." in the online version. Despite advances in surgical and anesthetic techniques, lower-extremity total joint arthroplasty is associated with considerable perioperative blood loss. As predictors of perioperative blood loss and allogenic blood transfusion have not yet been well defined, the purpose of this study was to identify clinical predictors for perioperative blood loss and allogenic blood transfusion in patients undergoing total joint arthroplasty. From 2000 to 2008, all patients undergoing unilateral primary total hip or knee arthroplasty who met the inclusion criteria were enrolled in the study. Perioperative blood loss was calculated with use of a previously validated formula. The predictors of perioperative blood loss and allogenic blood transfusion were identified in a multivariate analysis. Eleven thousand three hundred and seventy-three patients who underwent total joint arthroplasty, including 4769 patients who underwent total knee arthroplasty and 6604 patients who underwent total hip arthroplasty, were evaluated. Multivariate analysis indicated that an increase in blood loss was associated with being male (263.59 mL in male patients who had undergone total hip arthroplasty and 233.60 mL in male patients who had undergone total knee arthroplasty), a Charlson Comorbidity Index of >3 (293.99 mL in patients who had undergone total hip arthroplasty and 167.96 mL in patients who had undergone total knee arthroplasty), and preoperative autologous blood donation (593.51 mL in patients who had undergone total hip arthroplasty and 592.30 mL in patients who had undergone total knee arthroplasty). In patients who underwent total hip arthroplasty, regional anesthesia compared with general anesthesia reduced the amount of blood loss. The risk of allogenic blood transfusion increased with the amount of blood loss in the patients who underwent total hip arthroplasty (odds ratio, 1.43 [95% confidence interval, 1.40 to 1.46]) and the patients who underwent total knee arthroplasty (odds ratio, 1.47 [95% confidence interval, 1.42 to 1.51]), but the risk of blood transfusion increased with the Charlson Comorbidity Index only in patients who underwent total knee arthroplasty (odds ratio, 3.2 [95% confidence interval, 1.99 to 5.15]). The risk of allogenic blood transfusion decreased with preoperative autologous blood donation in patients who underwent total hip arthroplasty (odds ratio, 0.01 [95% confidence interval, 0.01 to 0.02]) and patients who underwent total knee arthroplasty (odds ratio, 0.02 [95% confidence interval, 0.01 to 0.03]). This study identified some clinical predictors for blood loss in patients undergoing total joint arthroplasty that we believe can be used for implementing more effective blood conservation strategies. Prognostic Level IV. See Instructions for Authors for a complete description of levels of evidence.
Onodera, Tomohiro; Majima, Tokifumi; Iwasaki, Norimasa; Kamishima, Tamotsu; Kasahara, Yasuhiko; Minami, Akio
2012-09-01
The stress distribution of an ankle under various physiological conditions is important for long-term survival of total ankle arthroplasty. The aim of this study was to measure subchondral bone density across the distal tibial joint surface in patients with malalignment/instability of the lower limb. We evaluated subchondral bone density across the distal tibial joint in patients with malalignment/instability of the knee by computed tomography (CT) osteoabsorptiometry from ten ankles as controls and from 27 ankles with varus deformity/instability of the knee. The quantitative analysis focused on the location of the high-density area at the articular surface, to determine the resultant long-term stress on the ankle joint. The area of maximum density of subchondral bone was located in the medial part in all subjects. The pattern of maximum density in the anterolateral area showed stepwise increases with the development of varus deformity/instability of the knee. Our results should prove helpful for designing new prostheses and determining clinical indications for total ankle arthroplasty.
Filho, Geraldo Motta; Galvão, Marcus Vinicius; Monteiro, Martim; Cohen, Marcio; Brandão, Bruno
2015-01-01
The study's objective is to evaluate the characteristics and problems of patients who underwent shoulder arthroplasties between July 2004 and November 2006. Methodology: During the period of the study, 145 shoulder arthroplasties were performed. A prospective protocol was used for every patient; demographic, clinical and surgical procedure data were collected. All gathered data were included in the data base. The patients were divided in three major groups: fractures, degenerative diseases and trauma sequels. Information obtained from the data base was correlated in order to determine patients' epidemiologic, injuries, and surgical procedure profiles. Results: Of the 145 shoulder arthroplasties performed, 37% presented trauma sequels, 30% degenerative diseases, and 33% proximal humerus fracture. 12% of the cases required total arthroplasties and 88% partial arthroplasties. Five major complications were observed on early postoperative period. Conclusion: Shoulder arthroplasties have become a common procedure in orthopaedic practice. Surgical records are important in evidencing progressive evolution and in enabling future clinical outcomes evaluation. PMID:26998463
Kim, Wanlim; Yoon, Pil Whan; Kwak, Hong Suk; Yoo, Jeong Joon; Kim, Hee Joong; Yoon, Kang Sup
2017-07-01
The high failure rate of cemented femoral components in the 1970s facilitated the improvement of the cementing technique and surface finishes such as polymethylmethacrylate (PMMA)-precoated stems, reporting a survival rate of >95% at 10 years from some studies. However, controversy persists regarding whether precoated femoral stems are associated with a longer revision-free prosthesis survival. The purpose of this study was to evaluate the clinical and radiological outcomes of PMMA-precoated femoral stems, and analyze factors associated with implant survival. We retrospectively reviewed 73 primary hybrid total hip arthroplasties performed using PMMA-precoated femoral stems. The mean age of the patients was 61 years. During the mean follow-up period of 13 years, 18 hips (24.7%) underwent aseptic loosening, and all of the loosened stems were subjected to revision surgery 8.8 years (range 4.6-15.5 years) from the index surgery. Younger age and poor cementing were significantly associated with aseptic loosening (P = 0.013 and P < 0.001, respectively). However, the aseptic loosening rate was also high at 13.1% even with a good cementing technique. In conclusion, the PMMA-precoated stem failed to show expected advantages and needs to be replaced with other surface finish stem designs. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 1300-1306, 2017. © 2016 Wiley Periodicals, Inc.
Nowakowski, Andrej M; Stangel, Melanie; Grupp, Thomas M; Valderrabano, Victor
2012-09-27
The important roles of the anterior cruciate ligament regarding knee stability, physiologic kinematics, and proprioception are unquestioned. Thus, various efforts have been made to retain the ACL during total knee arthroplasty (TKA). Neither of the existing solutions to this problem, i.e. bicruciate retaining prostheses and implantation of two unicondylar prostheses, has been successful because of concept-specific problems as well as general difficulties with implant fixation. The new transversal support tibial plateau concept is a prosthesis of two individual joint surfaces reinforced beneath the articular line by joint surface supports and buttressed by a single transversal support. This configuration, which enables retention of both cruciate ligaments, should provide good bone fixation and ensure long-term alignment of the individual joint surfaces. In the current study, four prototypes based on this novel concept were developed and the resulting primary stability was analyzed using adapted load testing. The test set-up, with the model-loading of specially prepared Sawbones® and a sinusoidal oscillating load transmission with 25 000 cycles over 10 increasing load levels, achieved subsidence, which enabled comparison of the four different model variants regarding primary stability in view of bone anchoring. The model variant (TSmobile) that allowed transverse glide of the joint surface supports along the transversal support revealed the largest subsidence. A rigid attachment of the joint surface supports of the transversal support tibial plateau thus appears to offer increased primary stability regarding bone anchoring.
Dillon, Mark T; Ake, Christopher F; Burke, Mary F; Singh, Anshuman; Yian, Edward H; Paxton, Elizabeth W; Navarro, Ronald A
2015-06-01
Shoulder arthroplasty is being performed in the United States with increasing frequency. We describe the medium-term findings from a large integrated healthcare system shoulder arthroplasty registry. Shoulder arthroplasty cases registered between January 2005 and June 2013 were included for analysis. The registry included patient characteristics, surgical information, implant data, attrition, and patient outcomes such as surgical site infections, venous thromboembolism, and revision procedures. During the study period, 6,336 primary cases were registered. Median follow-up time for all primaries was 3.3 years; 461 cases were lost to follow-up by ending of health plan membership. Primary cases were predominantly female (56%) and white (81%), with an average age of 70 years. The most common reason for surgery was osteoarthritis in 60% of cases, followed by acute fracture (17%) and rotator cuff tear arthropathy (15%). In elective shoulder arthroplasty procedures, 200 all-cause revisions (4%) were reported, with glenoid wear being the most common reason. Most arthroplasties were elective procedures: over half performed for osteoarthritis. Glenoid wear was the most common reason for revision of primary shoulder arthroplasty in elective cases.
Research progress of asymptomatic bacteriuria before arthroplasty: A systematic review.
Zhang, Qingyu; Liu, Lihua; Sun, Wei; Gao, Fuqiang; Cheng, Liming; Li, Zirong
2018-02-01
A high prevalence of asymptomatic bacteriuria exists in patients prior to arthroplasty, and urinary tract infection is considered to be a source of postoperative superficial wound and prosthetic joint infections. There is no consensus whether to screen for and treat asymptomatic bacteriuria before arthroplasty. To summarize the association between asymptomatic bacteriuria and complications after arthroplasty and to evaluate the clinical benefits of treating asymptomatic bacteriuria prior to arthroplasty. We systematically searched PubMed, Embase, and the Cochrane Library to retrieve potentially eligible articles. By screening the titles and abstracts of retrieved records and then reading the full texts of the remaining papers, we finally included 8 English-language articles in this systematic review. Asymptomatic bacteriuria prior to arthroplasty is significantly associated with an increased occurrence of postoperative prosthetic joint and superficial wound infections. However, there is little evidence for direct or hematogenous seeding of urinary infections, and treating asymptomatic bacteriuria before arthroplasty did not decrease the incidence of postoperative infectious complications. Asymptomatic bacteriuria is not a contraindication for arthroplasty, and the practice of routine preoperative screening for and treatment of asymptomatic bacteriuria should not be continued.
[Sports participation after joint arthroplasty].
Dauty, M; Letenneur, J
2007-12-01
To recommand sports activities after joint arthroplasty from the literature analysis, the French surgeon's opinion and wish patients. From the Medline data base interrogation according to keywords: Sports, Arthroplasty, Athletics, Physical training, two different readers, an orthopedic surgeon and a Physical Medicine and Rehabilitation physician selected articles in French or English language according to the level of proofs of the french classification of the Accreditation and Health Evaluation National Agency (Anaes). Professional practices were estimated by the interrogation of 30 orthopedic surgeons members of the french West Orthopaedics Society (SOO). The demand of sports practice was studied with patients recently operated for a primary total knee arthroplasty (TKA) after gonarthrosis. Twenty-two articles were selected from 305 articles obtained by the search according to keywords. Ten literature reviews are limited by the absence of prospective randomized study. A level II study and eleven level IV articles are reported. According to the subjective orthropedic surgeon's opinion, the objective results based on the joint load studied and the percentage of arthroplasty revision, sport is beneficial for the individual health but perhaps not for the arthroplasty survey. However, aerobic and leisure activities are recommended (walking, swimming, cycling) in agreement with the demand of the patients recently operated with a TKA. TKA differs from Total Hip Arthroplasty for jogging because of knee joint constraints during the knee flexion. A single study reports sports possibilities after shoulder arthroplasty and ankle arthroplasty and no study reports results after elbow arthroplasty.
Kurtz, Steven M; Lau, Edmund; Ong, Kevin L; Katz, Jeffrey N; Bozic, Kevin J
2016-05-01
The state of Massachusetts enacted universal health insurance in 2006. However it is unknown whether the increased access to care resulted in changes to surgical use or costs. We asked the following related research questions: compared with the United States as a whole, how did the (1) number of cases (as a percentage of the overall population, to account for changes in the overall population during the time surveyed), (2) payer mix, and (3) inpatient costs for arthroplasty change in Massachusetts after introduction of health insurance reform? We analyzed the use and cost of primary THAs and TKAs in Massachusetts using the State Inpatient Database (SID) between 2002 and 2011 compared with the Nationwide Inpatient Sample (NIS) during the same years. The SID captures 100% of inpatient procedures in Massachusetts, while the NIS is a nationally representative database of inpatient procedures for the United States. The SID and NIS are publicly available data sources from the Agency for Healthcare Research and Quality, and include information regarding procedure volumes, payer mixes, and costs. Inpatient costs were defined similarly in both databases by using hospital charges and an average cost-to-charge ratio that is unique for each hospital. The incidence of arthroplasties was calculated by dividing the procedure volume by the relevant population (either for Massachusetts or the entire country) based on public data from the United States Census bureau. The incidence of THAs and TKAs performed in Massachusetts increased steadily throughout the study period, and paralleled a similar increase in the United States as a whole. In Massachusetts, the incidence of THAs increased by 59% between 2002 and 2011, and the incidence of TKAs likewise increased by 80%. The trends for the incidence in total joint arthroplasties were similar to those for Massachusetts for the United States as a whole. The period of health insurance reform in Massachusetts was associated with a greater proportion of patients covered by Medicaid, Commonwealth Care, or Health Safety Net for THAs and TKAs. By 2011, universal health insurance in Massachusetts covered 2.45% of primary THAs and 2.77% of primary TKAs. Coverage for Medicaid in Massachusetts increased from 3.23% and 3.04% of THAs and TKAs in 2002 to 4.06% and 4.34% respectively in 2011. On average, Medicaid coverage was greater for TKAs in Massachusetts than across the United States during the study period. The introduction of health insurance reform had a minimal effect on the cost of total joint arthroplasties in Massachusetts. Although the costs of total joint arthroplasties in the United States were higher than those in Massachusetts, this difference narrowed substantially from 2002 to 2011, with the Massachusetts cost trending upward and the overall United States cost trending downward. Despite extending insurance coverage to the entire state of Massachusetts, there was little change in actual utilization trends for joint replacement. The enactment of universal health insurance coverage in Massachusetts appears to have been a nonevent insofar as the use and cost of total hip and knee surgeries is concerned in the state. Factors other than health insurance reform appear to be driving the growth in demand for arthroplasties in Massachusetts and are likely to do so as well in the United States under the Affordable Care Act of 2010.
Hip replacement in femoral head osteonecrosis: current concepts
Scaglione, Michelangelo; Fabbri, Luca; Celli, Fabio; Casella, Francesco; Guido, Giulio
2015-01-01
Summary Osteonecrosis of the femoral head is a destructive disease that usually affects young adults with high functional demands and can have devastating effects on hip joint. The treatment depends on extent and location of the necrosis lesion and on patient’s factors, that suggest disease progression, collapse probability and also implants survival. Non-idiopathic osteonecrosis patients had the worst outcome. There is not a gold standard treatment and frequently it is necessary a multidisciplinary approach. Preservation procedures of the femoral head are the first choice and can be attempted in younger patients without head collapse. Replacement procedure remains the main treatment after failure of preserving procedures and in the late-stage ONFH, involving collapse of the femoral head and degenerative changes to the acetabulum. Resurfacing procedure still has good results but the patient selection is a critical factor. Total hip arthroplasties had historically poor results in patients with osteonecrosis. More recently, reports have shown excellent results, but implant longevity and following revisions are still outstanding problems. PMID:27134633
Short Operative Duration and Surgical Site Infection Risk in Hip and Knee Arthroplasty Procedures
Dicks, Kristen V.; Baker, Arthur W.; Durkin, Michael J.; Anderson, Deverick J.; Moehring, Rebekah W.; Chen, Luke F.; Sexton, Daniel J.; Weber, David J.; Lewis, Sarah S.
2016-01-01
OBJECTIVE To determine the association (1) between shorter operative duration and surgical site infection (SSI) and (2) between surgeon median operative duration and SSI risk among first-time hip and knee arthroplasties. DESIGN Retrospective cohort study SETTING A total of 43 community hospitals located in the southeastern United States. PATIENTS Adults who developed SSIs according to National Healthcare Safety Network criteria within 365 days of first-time knee or hip arthroplasties performed between January 1, 2008 and December 31, 2012. METHODS Log-binomial regression models estimated the association (1) between operative duration and SSI outcome and (2) between surgeon median operative duration and SSI outcome. Hip and knee arthroplasties were evaluated in separate models. Each model was adjusted for American Society of Anesthesiology score and patient age. RESULTS A total of 25,531 hip arthroplasties and 42,187 knee arthroplasties were included in the study. The risk of SSI in knee arthroplasties with an operative duration shorter than the 25th percentile was 0.40 times the risk of SSI in knee arthroplasties with an operative duration between the 25th and 75th percentile (risk ratio [RR], 0.40; 95% confidence interval [CI], 0.38–0.56; P <.01). Short operative duration did not demonstrate significant association with SSI for hip arthroplasties (RR, 1.04; 95% CI, 0.79–1.37; P =.36). Knee arthroplasty surgeons with shorter median operative durations had a lower risk of SSI than surgeons with typical median operative durations (RR, 0.52; 95% CI, 0.43–0.64; P <.01). CONCLUSIONS Short operative durations were not associated with a higher SSI risk for knee or hip arthroplasty procedures in our analysis. PMID:26391277
Future Bearing Surfaces in Total Hip Arthroplasty
2014-01-01
One of the most important issues in the modern total hip arthroplasty (THA) is the bearing surface. Extensive research on bearing surfaces is being conducted to seek an ideal bearing surface for THA. The ideal bearing surface for THA should have superior wear characteristics and should be durable, bio-inert, cost-effective, and easy to implant. However, bearing surfaces that are currently being implemented do not completely fulfill these requirements, especially for young individuals for whom implant longevity is paramount. Even though various new bearing surfaces have been investigated, research is still ongoing, and only short-term results have been reported from clinical trials. Future bearing surfaces can be developed in the following ways: (1) change in design, (2) further improvement of polyethylene, (3) surface modification of the metal, (4) improvement in the ceramic, and (5) use of alternative, new materials. One way to reduce wear and impingement in THA is to make changes in its design by using a large femoral head, a monobloc metal shell with preassembled ceramic liner, dual mobility cups, a combination of different bearing surfaces, etc. Polyethylene has improved over time with the development of highly crosslinked polyethylene. Further improvements can be made by reinforcing it with vitamin E or multiwalled carbon nanotubes and by performing a surface modification with a biomembrane. Surface modifications with titanium nitride or titanium niobium nitride are implemented to try to improve the metal bearings. The advance to the fourth generation ceramics has shown relatively promising results, even in young patients. Nevertheless, further improvement is required to reduce fragility and squeaking. Alternative materials like diamond coatings on surfaces, carbon based composite materials, oxidized zirconium, silicon nitride, and sapphire are being sought. However, long-term studies are necessary to confirm the efficacy of these surfaces after enhancements have been made with regard to fixation technique and implant quality. PMID:24605198