Sample records for surgery computer-assisted

  1. Computer assisted surgery in preoperative planning of acetabular fracture surgery: state of the art.

    PubMed

    Boudissa, Mehdi; Courvoisier, Aurélien; Chabanas, Matthieu; Tonetti, Jérôme

    2018-01-01

    The development of imaging modalities and computer technology provides a new approach in acetabular surgery. Areas covered: This review describes the role of computer-assisted surgery (CAS) in understanding of the fracture patterns, in the virtual preoperative planning of the surgery and in the use of custom-made plates in acetabular fractures with or without 3D printing technologies. A Pubmed internet research of the English literature of the last 20 years was carried out about studies concerning computer-assisted surgery in acetabular fractures. The several steps for CAS in acetabular fracture surgery are presented and commented by the main author regarding to his personal experience. Expert commentary: Computer-assisted surgery in acetabular fractures is still initial experiences with promising results. Patient-specific biomechanical models considering soft tissues should be developed to allow a more realistic planning.

  2. Enhanced cephalomedullary nail lag screw placement and intraoperative tip-apex distance measurement with a novel computer assisted surgery system.

    PubMed

    Kuhl, Mitchell; Beimel, Claudia

    2016-10-01

    The goal of this study was to evaluate the ability of a novel computer assisted surgery system to guide ideal placement of a lag screw during cephalomedullary nailing and then accurately measure the tip-apex distance (TAD) measurement intraoperatively. Retrospective case review. Level II trauma hospital. The initial 98 consecutive clinical cases treated with a cephalomedullary nail in conjunction with a novel computer assisted surgery system were retrospectively reviewed. A novel computer assisted surgery system was utilized to enhance lag screw placement during cephalomedullary nailing procedures. The computer assisted surgery system calculates the TAD intraoperatively after final lag screw placement. The ideal TAD was considered to be within a range of 5mm-20mm. The ability of the computer assisted surgery system (CASS) to assist in placement of a lag screw within the ideal TAD was evaluated. Intraoperative TAD measurements provided by the computer assisted surgery system were then compared to standard postoperative TAD measurements on PACS (picture archiving and communication system) images to determine whether these measurements are equivalent. 79 cases (80.6%) were available with complete information for a retrospective review. All cases had CASS TAD and PACS TAD measurements >5mm and<20mm. In addition, no significant difference could be detected between the intraoperative CASS TAD and the postoperative PACS TAD (p=0.374, Wilcoxon Test; p=0.174, paired T-Test). A cut-out rate of 0% was observed in all patients who were treated with CASS in this case series (95% CI: 0 - 3.01%). The novel computer assisted surgery system tested here is an effective and reliable adjunct that can be utilized for optimal lag screw placement in cephalomedullary nailing procedures. The computer assisted surgery system provides an accurate intraoperative TAD measurement that is equivalent to the standard postoperative measurement utilizing PACS images. Therapeutic Level IV. Copyright © 2016 Elsevier Ltd. All rights reserved.

  3. Robotic surgery

    MedlinePlus

    Robot-assisted surgery; Robotic-assisted laparoscopic surgery; Laparoscopic surgery with robotic assistance ... computer station and directs the movements of a robot. Small surgical tools are attached to the robot's ...

  4. [The history and development of computer assisted orthopaedic surgery].

    PubMed

    Jenny, J-Y

    2006-10-01

    Computer assisted orthopaedic surgery (CAOS) was developed to improve the accuracy of surgical procedures. It has improved dramatically over the last years, being transformed from an experimental, laboratory procedure into a routine procedure theoretically available to every orthopaedic surgeon. The first field of application of computer assistance was neurosurgery. After the application of computer guided spinal surgery, the navigation of total hip and knee joints became available. Currently, several applications for computer assisted surgery are available. At the beginning of navigation, a preoperative CT-scan or several fluoroscopic images were necessary. The imageless systems allow the surgeon to digitize patient anatomy at the beginning of surgery without any preoperative imaging. The future of CAOS remains unknown, but there is no doubt that its importance will grow in the next 10 years, and that this technology will probably modify the conventional practice of orthopaedic surgery.

  5. Computer-assisted innovations in craniofacial surgery.

    PubMed

    Rudman, Kelli; Hoekzema, Craig; Rhee, John

    2011-08-01

    Reconstructive surgery for complex craniofacial defects challenges even the most experienced surgeons. Preoperative reconstructive planning requires consideration of both functional and aesthetic properties of the mandible, orbit, and midface. Technological innovations allow for computer-assisted preoperative planning, computer-aided manufacturing of patient-specific implants (PSIs), and computer-assisted intraoperative navigation. Although many case reports discuss computer-assisted preoperative planning and creation of custom implants, a general overview of computer-assisted innovations is not readily available. This article reviews innovations in computer-assisted reconstructive surgery including anatomic considerations when using PSIs, technologies available for preoperative planning, work flow and process of obtaining a PSI, and implant materials available for PSIs. A case example follows illustrating the use of this technology in the reconstruction of an orbital-frontal-temporal defect with a PSI. Computer-assisted reconstruction of complex craniofacial defects provides the reconstructive surgeon with innovative options for challenging reconstructive cases. As technology advances, applications of computer-assisted reconstruction will continue to expand. © Thieme Medical Publishers.

  6. Computer-assisted abdominal surgery: new technologies.

    PubMed

    Kenngott, H G; Wagner, M; Nickel, F; Wekerle, A L; Preukschas, A; Apitz, M; Schulte, T; Rempel, R; Mietkowski, P; Wagner, F; Termer, A; Müller-Stich, Beat P

    2015-04-01

    Computer-assisted surgery is a wide field of technologies with the potential to enable the surgeon to improve efficiency and efficacy of diagnosis, treatment, and clinical management. This review provides an overview of the most important new technologies and their applications. A MEDLINE database search was performed revealing a total of 1702 references. All references were considered for information on six main topics, namely image guidance and navigation, robot-assisted surgery, human-machine interface, surgical processes and clinical pathways, computer-assisted surgical training, and clinical decision support. Further references were obtained through cross-referencing the bibliography cited in each work. Based on their respective field of expertise, the authors chose 64 publications relevant for the purpose of this review. Computer-assisted systems are increasingly used not only in experimental studies but also in clinical studies. Although computer-assisted abdominal surgery is still in its infancy, the number of studies is constantly increasing, and clinical studies start showing the benefits of computers used not only as tools of documentation and accounting but also for directly assisting surgeons during diagnosis and treatment of patients. Further developments in the field of clinical decision support even have the potential of causing a paradigm shift in how patients are diagnosed and treated.

  7. Computer-assisted surgery and intraoral welding technique for immediate implant-supported rehabilitation of the edentulous maxilla: case report and technical description.

    PubMed

    Albiero, Alberto Maria; Benato, Renato

    2016-09-01

    Complications are frequently reported when combining computer assisted flapless surgery with an immediate loaded prefabricated prosthesis. The authors have combined computer-assisted surgery with the intraoral welding technique to obtain a precise passive fit of the immediate loading prosthesis. An edentulous maxilla was rehabilitated with four computer assisted implants welded together intraorally and immediately loaded with a provisional restoration. A perfect passive fit of the metal framework was obtained that enabled proper osseointegration of implants. Computer assisted preoperative planning has been shown to be effective in reducing the intraoperative time of the intraoral welding technique. No complications were observed at 1 year follow-up. This guided-welded approach is useful to achieve a passive fit of the provisional prosthesis on the inserted implants the same day as the surgery, reducing intraoperative time with respect to the traditional intraoral welding technique. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.

  8. Oral and maxillofacial surgery with computer-assisted navigation system.

    PubMed

    Kawachi, Homare; Kawachi, Yasuyuki; Ikeda, Chihaya; Takagi, Ryo; Katakura, Akira; Shibahara, Takahiko

    2010-01-01

    Intraoperative computer-assisted navigation has gained acceptance in maxillofacial surgery with applications in an increasing number of indications. We adapted a commercially available wireless passive marker system which allows calibration and tracking of virtually every instrument in maxillofacial surgery. Virtual computer-generated anatomical structures are displayed intraoperatively in a semi-immersive head-up display. Continuous observation of the operating field facilitated by computer assistance enables surgical navigation in accordance with the physician's preoperative plans. This case report documents the potential for augmented visualization concepts in surgical resection of tumors in the oral and maxillofacial region. We report a case of T3N2bM0 carcinoma of the maxillary gingival which was surgically resected with the assistance of the Stryker Navigation Cart System. This system was found to be useful in assisting preoperative planning and intraoperative monitoring.

  9. Computer-assisted preoperative simulation for positioning and fixation of plate in 2-stage procedure combining maxillary advancement by distraction technique and mandibular setback surgery.

    PubMed

    Suenaga, Hideyuki; Taniguchi, Asako; Yonenaga, Kazumichi; Hoshi, Kazuto; Takato, Tsuyoshi

    2016-01-01

    Computer-assisted preoperative simulation surgery is employed to plan and interact with the 3D images during the orthognathic procedure. It is useful for positioning and fixation of maxilla by a plate. We report a case of maxillary retrusion by a bilateral cleft lip and palate, in which a 2-stage orthognathic procedure (maxillary advancement by distraction technique and mandibular setback surgery) was performed following a computer-assisted preoperative simulation planning to achieve the positioning and fixation of the plate. A high accuracy was achieved in the present case. A 21-year-old male patient presented to our department with a complaint of maxillary retrusion following bilateral cleft lip and palate. Computer-assisted preoperative simulation with 2-stage orthognathic procedure using distraction technique and mandibular setback surgery was planned. The preoperative planning of the procedure resulted in good aesthetic outcomes. The error of the maxillary position was less than 1mm. The implementation of the computer-assisted preoperative simulation for the positioning and fixation of plate in 2-stage orthognathic procedure using distraction technique and mandibular setback surgery yielded good results. Copyright © 2016 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  10. Computer-assisted navigation in orthopedic surgery.

    PubMed

    Mavrogenis, Andreas F; Savvidou, Olga D; Mimidis, George; Papanastasiou, John; Koulalis, Dimitrios; Demertzis, Nikolaos; Papagelopoulos, Panayiotis J

    2013-08-01

    Computer-assisted navigation has a role in some orthopedic procedures. It allows the surgeons to obtain real-time feedback and offers the potential to decrease intra-operative errors and optimize the surgical result. Computer-assisted navigation systems can be active or passive. Active navigation systems can either perform surgical tasks or prohibit the surgeon from moving past a predefined zone. Passive navigation systems provide intraoperative information, which is displayed on a monitor, but the surgeon is free to make any decisions he or she deems necessary. This article reviews the available types of computer-assisted navigation, summarizes the clinical applications and reviews the results of related series using navigation, and informs surgeons of the disadvantages and pitfalls of computer-assisted navigation in orthopedic surgery. Copyright 2013, SLACK Incorporated.

  11. An economic model to evaluate cost-effectiveness of computer assisted knee replacement surgery in Norway.

    PubMed

    Gøthesen, Øystein; Slover, James; Havelin, Leif; Askildsen, Jan Erik; Malchau, Henrik; Furnes, Ove

    2013-07-06

    The use of Computer Assisted Surgery (CAS) for knee replacements is intended to improve the alignment of knee prostheses in order to reduce the number of revision operations. Is the cost effectiveness of computer assisted surgery influenced by patient volume and age? By employing a Markov model, we analysed the cost effectiveness of computer assisted surgery versus conventional arthroplasty with respect to implant survival and operation volume in two theoretical Norwegian age cohorts. We obtained mortality and hospital cost data over a 20-year period from Norwegian registers. We presumed that the cost of an intervention would need to be below NOK 500,000 per QALY (Quality Adjusted Life Year) gained, to be considered cost effective. The added cost of computer assisted surgery, provided this has no impact on implant survival, is NOK 1037 and NOK 1414 respectively for 60 and 75-year-olds per quality-adjusted life year at a volume of 25 prostheses per year, and NOK 128 and NOK 175 respectively at a volume of 250 prostheses per year. Sensitivity analyses showed that the 10-year implant survival in cohort 1 needs to rise from 89.8% to 90.6% at 25 prostheses per year, and from 89.8 to 89.9% at 250 prostheses per year for computer assisted surgery to be considered cost effective. In cohort 2, the required improvement is a rise from 95.1% to 95.4% at 25 prostheses per year, and from 95.10% to 95.14% at 250 prostheses per year. The cost of using computer navigation for total knee replacements may be acceptable for 60-year-old as well as 75-year-old patients if the technique increases the implant survival rate just marginally, and the department has a high operation volume. A low volume department might not achieve cost-effectiveness unless computer navigation has a more significant impact on implant survival, thus may defer the investments until such data are available.

  12. Computer-assisted surgery in the lower jaw: double surgical guide for immediately loaded implants in postextractive sites-technical notes and a case report.

    PubMed

    De Santis, Daniele; Canton, Luciano Claudio; Cucchi, Alessandro; Zanotti, Guglielmo; Pistoia, Enrico; Nocini, Pier Francesco

    2010-01-01

    Computer-assisted surgery is based on computerized tomography (CT) scan technology to plan the placement of dental implants and a computer-aided design/computer-aided manufacturing (CAD-CAM) technology to create a custom surgical template. It provides guidance for insertion implants after analysis of existing alveolar bone and planning of implant position, which can be immediately loaded, therefore achieving esthetic and functional results in a surgical stage. The absence of guidelines to treat dentulous areas is often due to a lack of computer-assisted surgery. The authors have attempted to use this surgical methodology to replace residual teeth with an immediate implantoprosthetic restoration. The aim of this case report is to show the possibility of treating a dentulous patient by applying a computer-assisted surgical protocol associated with the use of a double surgical template: one before extraction and a second one after extraction of selected teeth.

  13. Computer-assisted orthognathic surgery combined with fibular osteomyocutaneous flap reconstruction to correct facial asymmetry and maxillary defects secondary to maxillectomy in childhood.

    PubMed

    Zhang, Lei; Sun, Hao; Yu, Hong-bo; Yuan, Hao; Shen, Guo-fang; Wang, Xu-dong

    2013-05-01

    Maxillectomy in childhood not only causes composite primary defects but also secondary malformation of the middle and lower face. In the case presented, we introduced computer-assisted planning and simulation of orthognathic surgery combined with fibular osteomyocutaneous flap reconstruction to correct complex craniofacial deformities. Virtual orthognathic surgery and maxillary reconstruction surgery were undertaken preoperatively. LeFort I osteotomy, with bilateral sagittal split ramus osteotomy and lower border ostectomy, was performed to correct malocclusion and facial asymmetry. Maxillary reconstruction was accomplished using a fibular osteomyocutaneous flap. The patient recovered uneventfully with an adequate aesthetic appearance on 3D computed tomography. Our experience indicates that orthognathic surgery combined with fibular osteomyocutaneous flap reconstruction can used to correct complex facial asymmetry and maxillary defects secondary to maxillectomy. Computer-assisted simulation enables precise execution of the reconstruction. It shortens the free flap ischemia time and reduces the risks associated with microsurgery.

  14. History of computer-assisted orthopedic surgery (CAOS) in sports medicine.

    PubMed

    Jackson, Douglas W; Simon, Timothy M

    2008-06-01

    Computer-assisted orthopedic surgery and navigation applications have a history rooted in the desire to link imaging technology with real-time anatomic landmarks. Although applications are still evolving in the clinical and research setting, computer-assisted orthopedic surgery has already demonstrated in certain procedures its potential for improving the surgeon's accuracy, reproducibility (once past the learning curve), and in reducing outlier outcomes. It is also being used as an educational tool to assist less experienced surgeons in interpreting measurements and precision placements related to well defined anatomic landmarks. It also can assist experienced surgeons, in real-time, plan their bony cuts, tunnel placement, and with ligament balancing. Presently, the additional time, the expense to acquire the needed software and hardware, and restricted reimbursement have slowed the widespread use of navigation. Its current applications have been primarily in joint replacement surgery, spine surgery, and trauma. It has not been widely used in the clinical setting for sports medicine procedures. Sports medicine applications such as individualizing tunnel placement in ligament surgery, opening wedge osteotomy with and without accompanying ligament reconstruction, and balancing and tensioning of the ligaments during the procedure (allowing real-time corrections if necessary) are currently being evaluated and being used on a limited clinical basis.

  15. Medical imaging and registration in computer assisted surgery.

    PubMed

    Simon, D A; Lavallée, S

    1998-09-01

    Imaging, sensing, and computing technologies that are being introduced to aid in the planning and execution of surgical procedures are providing orthopaedic surgeons with a powerful new set of tools for improving clinical accuracy, reliability, and patient outcomes while reducing costs and operating times. Current computer assisted surgery systems typically include a measurement process for collecting patient specific medical data, a decision making process for generating a surgical plan, a registration process for aligning the surgical plan to the patient, and an action process for accurately achieving the goals specified in the plan. Some of the key concepts in computer assisted surgery applied to orthopaedics with a focus on the basic framework and underlying technologies is outlined. In addition, technical challenges and future trends in the field are discussed.

  16. Computer-assisted versus non-computer-assisted preoperative planning of corrective osteotomy for extra-articular distal radius malunions: a randomized controlled trial.

    PubMed

    Leong, Natalie L; Buijze, Geert A; Fu, Eric C; Stockmans, Filip; Jupiter, Jesse B

    2010-12-14

    Malunion is the most common complication of distal radius fracture. It has previously been demonstrated that there is a correlation between the quality of anatomical correction and overall wrist function. However, surgical correction can be difficult because of the often complex anatomy associated with this condition. Computer assisted surgical planning, combined with patient-specific surgical guides, has the potential to improve pre-operative understanding of patient anatomy as well as intra-operative accuracy. For patients with malunion of the distal radius fracture, this technology could significantly improve clinical outcomes that largely depend on the quality of restoration of normal anatomy. Therefore, the objective of this study is to compare patient outcomes after corrective osteotomy for distal radius malunion with and without preoperative computer-assisted planning and peri-operative patient-specific surgical guides. This study is a multi-center randomized controlled trial of conventional planning versus computer-assisted planning for surgical correction of distal radius malunion. Adult patients with extra-articular malunion of the distal radius will be invited to enroll in our study. After providing informed consent, subjects will be randomized to two groups: one group will receive corrective surgery with conventional preoperative planning, while the other will receive corrective surgery with computer-assisted pre-operative planning and peri-operative patient specific surgical guides. In the computer-assisted planning group, a CT scan of the affected forearm as well as the normal, contralateral forearm will be obtained. The images will be used to construct a 3D anatomical model of the defect and patient-specific surgical guides will be manufactured. Outcome will be measured by DASH and PRWE scores, grip strength, radiographic measurements, and patient satisfaction at 3, 6, and 12 months postoperatively. Computer-assisted surgical planning, combined with patient-specific surgical guides, is a powerful new technology that has the potential to improve the accuracy and consistency of orthopaedic surgery. To date, the role of this technology in upper extremity surgery has not been adequately investigated, and it is unclear whether its use provides any significant clinical benefit over traditional preoperative imaging protocols. Our study will represent the first randomized controlled trial investigating the use of computer assisted surgery in corrective osteotomy for distal radius malunions. NCT01193010.

  17. Computer-assisted stereotactic neurological surgery: pre-planning and on-site real-time operating control and simulation system

    NASA Astrophysics Data System (ADS)

    Zamorano, Lucia J.; Jiang, Charlie Z. W.

    1993-09-01

    In this decade the concept and development of computer assisted stereotactic neurological surgery has improved dramatically. First, the computer network replaced the tape as the data transportation media. Second, newer systems include multi-modality image correlation and frameless stereotactics as an integral part of their functionality, and offer extensive assistance to the neurosurgeon from the preplanning stages to and throughout the operation itself. These are very important changes, and have spurred the development of many interesting techniques. Successful systems include the ISG and NSPS-3.0.

  18. Computer-assisted total hip arthroplasty: coding the next generation of navigation systems for orthopedic surgery.

    PubMed

    Renkawitz, Tobias; Tingart, Markus; Grifka, Joachim; Sendtner, Ernst; Kalteis, Thomas

    2009-09-01

    This article outlines the scientific basis and a state-of-the-art application of computer-assisted orthopedic surgery in total hip arthroplasty (THA) and provides a future perspective on this technology. Computer-assisted orthopedic surgery in primary THA has the potential to couple 3D simulations with real-time evaluations of surgical performance, which has brought these developments from the research laboratory all the way to clinical use. Nonimage- or imageless-based navigation systems without the need for additional pre- or intra-operative image acquisition have stood the test to significantly reduce the variability in positioning the acetabular component and have shown precise measurement of leg length and offset changes during THA. More recently, computer-assisted orthopedic surgery systems have opened a new frontier for accurate surgical practice in minimally invasive, tissue-preserving THA. The future generation of imageless navigation systems will switch from simple measurement tasks to real navigation tools. These software algorithms will consider the cup and stem as components of a coupled biomechanical system, navigating the orthopedic surgeon to find an optimized complementary component orientation rather than target values intraoperatively, and are expected to have a high impact on clinical practice and postoperative functionality in modern THA.

  19. How to set up a robotic-assisted laparoscopic surgery center and training of staff.

    PubMed

    Lenihan, John P

    2017-11-01

    The use of computers to assist surgeons in the operating room has been an inevitable evolution in the modern practice of surgery. Robotic-assisted surgery has been evolving now for over two decades and has finally matured into a technology that has caused a monumental shift in the way gynecologic surgeries are performed. Prior to robotics, the only minimally invasive options for most Gynecologic (GYN) procedures including hysterectomies were either vaginal or laparoscopic approaches. However, even with over 100 years of vaginal surgery experience and more than 20 years of laparoscopic advancements, most gynecologic surgeries in the United States were still performed through an open incision. However, this changed in 2005 when the FDA approved the da Vinci Surgical Robotic System tm for use in gynecologic surgery. Over the last decade, the trend for gynecologic surgeries has now dramatically shifted to less open and more minimally invasive procedures. Robotic-assisted surgeries now include not only hysterectomy but also most all other commonly performed gynecologic procedures including myomectomies, pelvic support procedures, and reproductive surgeries. This success, however, has not been without controversies, particularly around costs and complications. The evolution of computers to assist surgeons and make minimally invasive procedures more common is clearly a trend that is not going away. It is now incumbent on surgeons, hospitals, and medical societies to determine the most cost-efficient and productive use for this technology. This process is best accomplished by developing a Robotics Program in each hospital that utilizes robotic surgery. Copyright © 2017. Published by Elsevier Ltd.

  20. Towards ubiquitous access of computer-assisted surgery systems.

    PubMed

    Liu, Hui; Lufei, Hanping; Shi, Weishong; Chaudhary, Vipin

    2006-01-01

    Traditional stand-alone computer-assisted surgery (CAS) systems impede the ubiquitous and simultaneous access by multiple users. With advances in computing and networking technologies, ubiquitous access to CAS systems becomes possible and promising. Based on our preliminary work, CASMIL, a stand-alone CAS server developed at Wayne State University, we propose a novel mobile CAS system, UbiCAS, which allows surgeons to retrieve, review and interpret multimodal medical images, and to perform some critical neurosurgical procedures on heterogeneous devices from anywhere at anytime. Furthermore, various optimization techniques, including caching, prefetching, pseudo-streaming-model, and compression, are used to guarantee the QoS of the UbiCAS system. UbiCAS enables doctors at remote locations to actively participate remote surgeries, share patient information in real time before, during, and after the surgery.

  1. What Is Heart Surgery?

    MedlinePlus

    ... heart surgery that is becoming more common is robotic-assisted surgery. For this surgery, a surgeon uses a computer ... surgeon always is in total control of the robotic arms; they don't move on their own. Who Needs Heart Surgery? Heart surgery is used to treat many heart ...

  2. Computer-assisted surgery planning in children with complex liver tumors identifies variability of the classical Couinaud classification.

    PubMed

    Warmann, Steven W; Schenk, Andrea; Schaefer, Juergen F; Ebinger, Martin; Blumenstock, Gunnar; Tsiflikas, Ilias; Fuchs, Joerg

    2016-11-01

    In complex malignant pediatric liver tumors there is an ongoing discussion regarding surgical strategy; for example, primary organ transplantation versus extended resection in hepatoblastoma involving 3 or 4 sectors of the liver. We evaluated the possible role of computer-assisted surgery planning in children with complex hepatic tumors. Between May 2004 and March 2016, 24 Children with complex liver tumors underwent standard multislice helical CT scan or MRI scan at our institution. Imaging data were processed using the software assistant LiverAnalyzer (Fraunhofer Institute for Medical Image Computing MEVIS, Bremen, Germany). Results were provided as Portable Document Format (PDF) with embedded interactive 3-dimensional surface mesh models. Median age of patients was 33months. Diagnoses were hepatoblastoma (n=14), sarcoma (n=3), benign parenchyma alteration (n=2), as well as hepatocellular carcinoma, rhabdoid tumor, focal nodular hyperplasia, hemangioendothelioma, or multiple hepatic metastases of a pancreas carcinoma (each n=1). Volumetry of liver segments identified remarkable variations and substantial aberrances from the Couinaud classification. Computer-assisted surgery planning was used to determine surgical strategies in 20/24 children; this was especially relevant in tumors affecting 3 or 4 liver sectors. Primary liver transplantation could be avoided in 12 of 14 hepaoblastoma patients who theoretically were candidates for this approach. Computer-assisted surgery planning substantially contributed to the decision for surgical strategies in children with complex hepatic tumors. This tool possibly allows determination of specific surgical procedures such as extended surgical resection instead of primary transplantation in certain conditions. Copyright © 2016. Published by Elsevier Inc.

  3. Preliminary development of a workstation for craniomaxillofacial surgical procedures: introducing a computer-assisted planning and execution system.

    PubMed

    Gordon, Chad R; Murphy, Ryan J; Coon, Devin; Basafa, Ehsan; Otake, Yoshito; Al Rakan, Mohammed; Rada, Erin; Susarla, Srinivas; Susarla, Sriniras; Swanson, Edward; Fishman, Elliot; Santiago, Gabriel; Brandacher, Gerald; Liacouras, Peter; Grant, Gerald; Armand, Mehran

    2014-01-01

    Facial transplantation represents one of the most complicated scenarios in craniofacial surgery because of skeletal, aesthetic, and dental discrepancies between donor and recipient. However, standard off-the-shelf vendor computer-assisted surgery systems may not provide custom features to mitigate the increased complexity of this particular procedure. We propose to develop a computer-assisted surgery solution customized for preoperative planning, intraoperative navigation including cutting guides, and dynamic, instantaneous feedback of cephalometric measurements/angles as needed for facial transplantation and other related craniomaxillofacial procedures. We developed the Computer-Assisted Planning and Execution (CAPE) workstation to assist with planning and execution of facial transplantation. Preoperative maxillofacial computed tomography (CT) scans were obtained on 4 size-mismatched miniature swine encompassing 2 live face-jaw-teeth transplants. The system was tested in a laboratory setting using plastic models of mismatched swine, after which the system was used in 2 live swine transplants. Postoperative CT imaging was obtained and compared with the preoperative plan and intraoperative measures from the CAPE workstation for both transplants. Plastic model tests familiarized the team with the CAPE workstation and identified several defects in the workflow. Live swine surgeries demonstrated utility of the CAPE system in the operating room, showing submillimeter registration error of 0.6 ± 0.24 mm and promising qualitative comparisons between intraoperative data and postoperative CT imaging. The initial development of the CAPE workstation demonstrated that integration of computer planning and intraoperative navigation for facial transplantation are possible with submillimeter accuracy. This approach can potentially improve preoperative planning, allowing ideal donor-recipient matching despite significant size mismatch, and accurate surgical execution for numerous types of craniofacial and orthognathic surgical procedures.

  4. Self-learning computers for surgical planning and prediction of postoperative alignment.

    PubMed

    Lafage, Renaud; Pesenti, Sébastien; Lafage, Virginie; Schwab, Frank J

    2018-02-01

    In past decades, the role of sagittal alignment has been widely demonstrated in the setting of spinal conditions. As several parameters can be affected, identifying the driver of the deformity is the cornerstone of a successful treatment approach. Despite the importance of restoring sagittal alignment for optimizing outcome, this task remains challenging. Self-learning computers and optimized algorithms are of great interest in spine surgery as in that they facilitate better planning and prediction of postoperative alignment. Nowadays, computer-assisted tools are part of surgeons' daily practice; however, the use of such tools remains to be time-consuming. NARRATIVE REVIEW AND RESULTS: Computer-assisted methods for the prediction of postoperative alignment consist of a three step analysis: identification of anatomical landmark, definition of alignment objectives, and simulation of surgery. Recently, complex rules for the prediction of alignment have been proposed. Even though this kind of work leads to more personalized objectives, the number of parameters involved renders it difficult for clinical use, stressing the importance of developing computer-assisted tools. The evolution of our current technology, including machine learning and other types of advanced algorithms, will provide powerful tools that could be useful in improving surgical outcomes and alignment prediction. These tools can combine different types of advanced technologies, such as image recognition and shape modeling, and using this technique, computer-assisted methods are able to predict spinal shape. The development of powerful computer-assisted methods involves the integration of several sources of information such as radiographic parameters (X-rays, MRI, CT scan, etc.), demographic information, and unusual non-osseous parameters (muscle quality, proprioception, gait analysis data). In using a larger set of data, these methods will aim to mimic what is actually done by spine surgeons, leading to real tailor-made solutions. Integrating newer technology can change the current way of planning/simulating surgery. The use of powerful computer-assisted tools that are able to integrate several parameters and learn from experience can change the traditional way of selecting treatment pathways and counseling patients. However, there is still much work to be done to reach a desired level as noted in other orthopedic fields, such as hip surgery. Many of these tools already exist in non-medical fields and their adaptation to spine surgery is of considerable interest.

  5. [Basic concept in computer assisted surgery].

    PubMed

    Merloz, Philippe; Wu, Hao

    2006-03-01

    To investigate application of medical digital imaging systems and computer technologies in orthopedics. The main computer-assisted surgery systems comprise the four following subcategories. (1) A collection and recording process for digital data on each patient, including preoperative images (CT scans, MRI, standard X-rays), intraoperative visualization (fluoroscopy, ultrasound), and intraoperative position and orientation of surgical instruments or bone sections (using 3D localises). Data merging based on the matching of preoperative imaging (CT scans, MRI, standard X-rays) and intraoperative visualization (anatomical landmarks, or bone surfaces digitized intraoperatively via 3D localiser; intraoperative ultrasound images processed for delineation of bone contours). (2) In cases where only intraoperative images are used for computer-assisted surgical navigation, the calibration of the intraoperative imaging system replaces the merged data system, which is then no longer necessary. (3) A system that provides aid in decision-making, so that the surgical approach is planned on basis of multimodal information: the interactive positioning of surgical instruments or bone sections transmitted via pre- or intraoperative images, display of elements to guide surgical navigation (direction, axis, orientation, length and diameter of a surgical instrument, impingement, etc. ). And (4) A system that monitors the surgical procedure, thereby ensuring that the optimal strategy defined at the preoperative stage is taken into account. It is possible that computer-assisted orthopedic surgery systems will enable surgeons to better assess the accuracy and reliability of the various operative techniques, an indispensable stage in the optimization of surgery.

  6. [Georg Schlöndorff-the father of computer-assisted surgery].

    PubMed

    Mösges, R

    2016-09-01

    Georg Schlöndorff (1931-2011) developed the idea of computer-assisted surgery (CAS) during his time as professor and chairman of the Department of Otorhinolaryngology at the Medical Faculty of the University of Aachen, Germany. In close cooperation with engineers and physicists, he succeeded in translating this concept into a functional prototype that was applied in live surgery in the operating theatre. The first intervention performed with this image-guided navigation system was a skull base surgical procedure 1987. During the following years, this concept was extended to orbital surgery, neurosurgery, mid-facial traumatology, and brachytherapy of solid tumors in the head and neck region. Further technical developments of this first prototype included touchless optical positioning and the computer vision concept with three orthogonal images, which is still common in contemporary navigation systems. During his time as emeritus professor from 1996, Georg Schlöndorff further pursued his concept of CAS by developing technical innovations such as computational fluid dynamics (CFD).

  7. Ontology-based prediction of surgical events in laparoscopic surgery

    NASA Astrophysics Data System (ADS)

    Katić, Darko; Wekerle, Anna-Laura; Gärtner, Fabian; Kenngott, Hannes; Müller-Stich, Beat Peter; Dillmann, Rüdiger; Speidel, Stefanie

    2013-03-01

    Context-aware technologies have great potential to help surgeons during laparoscopic interventions. Their underlying idea is to create systems which can adapt their assistance functions automatically to the situation in the OR, thus relieving surgeons from the burden of managing computer assisted surgery devices manually. To this purpose, a certain kind of understanding of the current situation in the OR is essential. Beyond that, anticipatory knowledge of incoming events is beneficial, e.g. for early warnings of imminent risk situations. To achieve the goal of predicting surgical events based on previously observed ones, we developed a language to describe surgeries and surgical events using Description Logics and integrated it with methods from computational linguistics. Using n-Grams to compute probabilities of followup events, we are able to make sensible predictions of upcoming events in real-time. The system was evaluated on professionally recorded and labeled surgeries and showed an average prediction rate of 80%.

  8. Developing a computer game to prepare children for surgery.

    PubMed

    Rassin, Michal; Gutman, Yaira; Silner, Dina

    2004-12-01

    Computer games are a major part of the culture of children and teenagers in many developed countries. Research shows that children of the computer age prefer computer-assisted learning to any other teaching strategy. Health care workers traditionally have used dolls, games, drawings, creative arts, and even videotapes to prepare children for surgery. No studies have been conducted in Israel on using computers to help ailing children in general or to help children preparing for surgery in particular. This article discusses the potential for using computers to educate patients based on a review of the literature and interviews with children and describes the process of computer game development.

  9. [Guided and computer-assisted implant surgery and prosthetic: The continuous digital workflow].

    PubMed

    Pascual, D; Vaysse, J

    2016-02-01

    New continuous digital workflow protocols of guided and computer-assisted implant surgery improve accuracy of implant positioning. The design of the future prosthesis is based on the available prosthetic space, gingival height and occlusal relationship with the opposing and adjacent teeth. The implant position and length depend on volume, density and bone quality, gingival height, tooth-implant and implant-implant distances, implant parallelism, axis and type of the future prosthesis. The crown modeled on the software will therefore serve as a guide to the future implant axis and not the reverse. The guide is made by 3D printing. The software determines surgical protocol with the drilling sequences. The unitary or plural prosthesis, modeled on the software and built before surgery, is loaded directly after implant placing, if needed. These protocols allow for a full continuity of the digital workflow. The software provides the surgeon and the dental technician a total freedom for the prosthetic-surgery guide design and the position of the implants. The prosthetic project, occlusal and aesthetic, taking the bony and surgical constraints into account, is optimized. The implant surgery is simplified and becomes less "stressful" for the patient and the surgeon. Guided and computer-assisted surgery with continuous digital workflow is becoming the technique of choice to improve the accuracy and quality of implant rehabilitation. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  10. Early experiences of endoscopic procedures in general surgery assisted by a computer-enhanced surgical system.

    PubMed

    Hashizume, M; Shimada, M; Tomikawa, M; Ikeda, Y; Takahashi, I; Abe, R; Koga, F; Gotoh, N; Konishi, K; Maehara, S; Sugimachi, K

    2002-08-01

    We performed a variety of complete total endoscopic general surgical procedures, including colon resection, distal gastrectomy, and splenectomy, successfully with the assistance of the da Vinci computer-enhanced surgical system. The robotic system allowed us to manipulate the endoscopic instruments as effectively as during open surgery. It enhanced visualization of both the operative field and precision of the necessary techniques, as well as being less stressful for the endoscopic operating team. This technological innovation can therefore help surgeons overcome many of the difficulties associated with the endoscopic approach and thus has the potential to enable more precise, safer, and more minimally invasive surgery in the future.

  11. Video-assisted thoracoscopic surgery for pulmonary nodules after computed tomography-guided marking with a spiral wire.

    PubMed

    Eichfeld, Uwe; Dietrich, Arne; Ott, Rudolph; Kloeppel, Rainer

    2005-01-01

    Peripheral pulmonary nodules are preferably removed by minimally invasive techniques, such as video-assisted thoracoscopic (VATS) surgery. These nodules should be marked preoperatively for better intraoperative detection and removal. Twenty-two cases with a single pulmonary nodule requiring surgical removal for histologic examination were included in a prospective study. Guided by computed tomography, nodules were marked preoperatively using a laser marker system and fixed with a spiral wire. The marked nodules were removed by VATS surgery immediately after the marking. The marking wire was placed in all 22 patients without any complications. The marked nodule was completely removed by VATS surgery in 19 patients. Conversion to thoracotomy was necessary in 3 patients, twice because of thoracoscopy-related problems and once because of a marking failure. The average times for the marking procedure and operation were 24 minutes and 32 minutes, respectively. This new method of computed tomography-guided nodule marking with a spiral wire and subsequent VATS surgery is very efficient in terms of localization and stable fixation of subpleural pulmonary nodules.

  12. Intraoperative 3-Dimensional Computed Tomography and Navigation in Foot and Ankle Surgery.

    PubMed

    Chowdhary, Ashwin; Drittenbass, Lisca; Dubois-Ferrière, Victor; Stern, Richard; Assal, Mathieu

    2016-09-01

    Computer-assisted orthopedic surgery has developed dramatically during the past 2 decades. This article describes the use of intraoperative 3-dimensional computed tomography and navigation in foot and ankle surgery. Traditional imaging based on serial radiography or C-arm-based fluoroscopy does not provide simultaneous real-time 3-dimensional imaging, and thus leads to suboptimal visualization and guidance. Three-dimensional computed tomography allows for accurate intraoperative visualization of the position of bones and/or navigation implants. Such imaging and navigation helps to further reduce intraoperative complications, leads to improved surgical outcomes, and may become the gold standard in foot and ankle surgery. [Orthopedics.2016; 39(5):e1005-e1010.]. Copyright 2016, SLACK Incorporated.

  13. The current status and future prospects of computer-assisted hip surgery.

    PubMed

    Inaba, Yutaka; Kobayashi, Naomi; Ike, Hiroyuki; Kubota, So; Saito, Tomoyuki

    2016-03-01

    The advances in computer assistance technology have allowed detailed three-dimensional preoperative planning and simulation of preoperative plans. The use of a navigation system as an intraoperative assistance tool allows more accurate execution of the preoperative plan, compared to manual operation without assistance of the navigation system. In total hip arthroplasty using CT-based navigation, three-dimensional preoperative planning with computer software allows the surgeon to determine the optimal angle of implant placement at which implant impingement is unlikely to occur in the range of hip joint motion necessary for daily activities of living, and to determine the amount of three-dimensional correction for leg length and offset. With the use of computer navigation for intraoperative assistance, the preoperative plan can be precisely executed. In hip osteotomy using CT-based navigation, the navigation allows three-dimensional preoperative planning, intraoperative confirmation of osteotomy sites, safe performance of osteotomy even under poor visual conditions, and a reduction in exposure doses from intraoperative fluoroscopy. Positions of the tips of chisels can be displayed on the computer monitor during surgery in real time, and staff other than the operator can also be aware of the progress of surgery. Thus, computer navigation also has an educational value. On the other hand, its limitations include the need for placement of trackers, increased radiation exposure from preoperative CT scans, and prolonged operative time. Moreover, because the position of a bone fragment cannot be traced after osteotomy, methods to find its precise position after its movement need to be developed. Despite the need to develop methods for the postoperative evaluation of accuracy for osteotomy, further application and development of these systems are expected in the future. Copyright © 2016 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.

  14. Multi-slice computed tomography-assisted endoscopic transsphenoidal surgery for pituitary macroadenoma: a comparison with conventional microscopic transsphenoidal surgery.

    PubMed

    Tosaka, Masahiko; Nagaki, Tomohito; Honda, Fumiaki; Takahashi, Katsumasa; Yoshimoto, Yuhei

    2015-11-01

    Intraoperative computed tomography (iCT) is a reliable method for the detection of residual tumour, but previous single-slice low-resolution computed tomography (CT) without coronal or sagittal reconstructions was not of adequate quality for clinical use. The present study evaluated the results of multi-slice iCT-assisted endoscopic transsphenoidal surgery for pituitary macroadenoma. This retrospective study included 30 consecutive patients with newly diagnosed or recurrent pituitary macroadenoma with supradiaphragmatic extension who underwent endoscopic transsphenoidal surgery using iCT (eTSS+iCT group), and control 30 consecutive patients who underwent conventional endoscope-assisted transsphenoidal surgery (cTSS group). The tumour volume was calculated by multiplying the tumour area by the slice thickness. Visual acuity and visual field were estimated by the visual impairment score (VIS). The resection extent, (preoperative tumour volume - postoperative residual tumour volume)/preoperative tumour volume, was 98.9% (median) in the eTSS+iCT group and 91.7% in the cTSS group, and had significant difference between the groups (P = 0.04). Greater than 95 and >90% removal rates were significantly higher in the eTSS+iCT group than in the cTSS group (P = 0.02 and P = 0.001, respectively). However, improvement in VIS showed no significant difference between the groups. The rate of complications also showed no significant difference. Multi-slice iCT-assisted endoscopic transsphenoidal surgery may improve the resection extent of pituitary macroadenoma. Multi-slice iCT may have advantages over intraoperative magnetic resonance imaging in less expensive, short acquisition time, and that special protection against magnetic fields is not needed.

  15. Current state of computer navigation and robotics in unicompartmental and total knee arthroplasty: a systematic review with meta-analysis.

    PubMed

    van der List, Jelle P; Chawla, Harshvardhan; Joskowicz, Leo; Pearle, Andrew D

    2016-11-01

    Recently, there is a growing interest in surgical variables that are intraoperatively controlled by orthopaedic surgeons, including lower leg alignment, component positioning and soft tissues balancing. Since more tight control over these factors is associated with improved outcomes of unicompartmental knee arthroplasty and total knee arthroplasty (TKA), several computer navigation and robotic-assisted systems have been developed. Although mechanical axis accuracy and component positioning have been shown to improve with computer navigation, no superiority in functional outcomes has yet been shown. This could be explained by the fact that many differences exist between the number and type of surgical variables these systems control. Most systems control lower leg alignment and component positioning, while some in addition control soft tissue balancing. Finally, robotic-assisted systems have the additional advantage of improving surgical precision. A systematic search in PubMed, Embase and Cochrane Library resulted in 40 comparative studies and three registries on computer navigation reporting outcomes of 474,197 patients, and 21 basic science and clinical studies on robotic-assisted knee arthroplasty. Twenty-eight of these comparative computer navigation studies reported Knee Society Total scores in 3504 patients. Stratifying by type of surgical variables, no significant differences were noted in outcomes between surgery with computer-navigated TKA controlling for alignment and component positioning versus conventional TKA (p = 0.63). However, significantly better outcomes were noted following computer-navigated TKA that also controlled for soft tissue balancing versus conventional TKA (mean difference 4.84, 95 % Confidence Interval 1.61, 8.07, p = 0.003). A literature review of robotic systems showed that these systems can, similarly to computer navigation, reliably improve lower leg alignment, component positioning and soft tissues balancing. Furthermore, two studies comparing robotic-assisted with computer-navigated surgery reported superiority of robotic-assisted surgery in controlling these factors. Manually controlling all these surgical variables can be difficult for the orthopaedic surgeon. Findings in this study suggest that computer navigation or robotic assistance may help managing these multiple variables and could improve outcomes. Future studies assessing the role of soft tissue balancing in knee arthroplasty and long-term follow-up studies assessing the role of computer-navigated and robotic-assisted knee arthroplasty are needed.

  16. Robot-assisted general surgery.

    PubMed

    Hazey, Jeffrey W; Melvin, W Scott

    2004-06-01

    With the initiation of laparoscopic techniques in general surgery, we have seen a significant expansion of minimally invasive techniques in the last 16 years. More recently, robotic-assisted laparoscopy has moved into the general surgeon's armamentarium to address some of the shortcomings of laparoscopic surgery. AESOP (Computer Motion, Goleta, CA) addressed the issue of visualization as a robotic camera holder. With the introduction of the ZEUS robotic surgical system (Computer Motion), the ability to remotely operate laparoscopic instruments became a reality. US Food and Drug Administration approval in July 2000 of the da Vinci robotic surgical system (Intuitive Surgical, Sunnyvale, CA) further defined the ability of a robotic-assist device to address limitations in laparoscopy. This includes a significant improvement in instrument dexterity, dampening of natural hand tremors, three-dimensional visualization, ergonomics, and camera stability. As experience with robotic technology increased and its applications to advanced laparoscopic procedures have become more understood, more procedures have been performed with robotic assistance. Numerous studies have shown equivalent or improved patient outcomes when robotic-assist devices are used. Initially, robotic-assisted laparoscopic cholecystectomy was deemed safe, and now robotics has been shown to be safe in foregut procedures, including Nissen fundoplication, Heller myotomy, gastric banding procedures, and Roux-en-Y gastric bypass. These techniques have been extrapolated to solid-organ procedures (splenectomy, adrenalectomy, and pancreatic surgery) as well as robotic-assisted laparoscopic colectomy. In this chapter, we review the evolution of robotic technology and its applications in general surgical procedures.

  17. Development and Evaluation of an Interactive Computer-Assisted Learning Program--A Novel Approach to Teaching Gynaecological Surgery.

    ERIC Educational Resources Information Center

    Jha, Vikram; Widdowson, Shelley; Duffy, Sean

    2002-01-01

    Discusses computer-assisted learning (CAL) in medical education and describes the development of an interactive CAL program on CD-ROM, combining video, illustrations, and three-dimensional images, to enhance understanding of vaginal hysterectomy in terms of the anatomy and steps of the surgical procedure. (Author/LRW)

  18. Markerless laser registration in image-guided oral and maxillofacial surgery.

    PubMed

    Marmulla, Rüdiger; Lüth, Tim; Mühling, Joachim; Hassfeld, Stefan

    2004-07-01

    The use of registration markers in computer-assisted surgery is combined with high logistic costs and efforts. Markerless patient registration using laser scan surface registration techniques is a new challenging method. The present study was performed to evaluate the clinical accuracy in finding defined target points within the surgical site after markerless patient registration in image-guided oral and maxillofacial surgery. Twenty consecutive patients with different cranial diseases were scheduled for computer-assisted surgery. Data set alignment between the surgical site and the computed tomography (CT) data set was performed by markerless laser scan surface registration of the patient's face. Intraoral rigidly attached registration markers were used as target points, which had to be detected by an infrared pointer. The Surgical Segment Navigator SSN++ has been used for all procedures. SSN++ is an investigative product based on the SSN system that had previously been developed by the presenting authors with the support of Carl Zeiss (Oberkochen, Germany). SSN++ is connected to a Polaris infrared camera (Northern Digital, Waterloo, Ontario, Canada) and to a Minolta VI 900 3D digitizer (Tokyo, Japan) for high-resolution laser scanning. Minimal differences in shape between the laser scan surface and the surface generated from the CT data set could be detected. Nevertheless, high-resolution laser scan of the skin surface allows for a precise patient registration (mean deviation 1.1 mm, maximum deviation 1.8 mm). Radiation load, logistic costs, and efforts arising from the planning of computer-assisted surgery of the head can be reduced because native (markerless) CT data sets can be used for laser scan-based surface registration.

  19. Applications of computer assisted surgery and medical robotics at the ISSSTE, México: preliminary results.

    PubMed

    Mosso, José Luis; Pohl, Mauricio; Jimenez, Juan Ramon; Valdes, Raquel; Yañez, Oscar; Medina, Veronica; Arambula, Fernando; Padilla, Miguel Angel; Marquez, Jorge; Gastelum, Alfonso; Mosso, Alejo; Frausto, Juan

    2007-01-01

    We present the first results of four projects of a second phase of a Mexican Project Computer Assisted Surgery and Medical Robotics, supported by the Mexican Science and Technology National Council (Consejo Nacional de Ciencia y Tecnología) under grant SALUD-2002-C01-8181. The projects are being developed by three universities (UNAM, UAM, ITESM) and the goal of this project is to integrate a laboratory in a Hospital of the ISSSTE to give service to surgeons or clinicians of Endoscopic surgeons, urologist, gastrointestinal endoscopist and neurosurgeons.

  20. The Leipzig experience with robotic valve surgery.

    PubMed

    Autschbach, R; Onnasch, J F; Falk, V; Walther, T; Krüger, M; Schilling, L O; Mohr, F W

    2000-01-01

    The study describes the single-center experience using robot-assisted videoscopic mitral valve surgery and the early results with a remote telemanipulator-assisted approach for mitral valve repair. Out of a series of 230 patients who underwent minimally invasive mitral valve surgery, in 167 patients surgery was performed with the use of robotic assistance. A voice-controlled robotic arm was used for videoscopic guidance in 152 cases. Most recently, a computer-enhanced telemanipulator was used in 15 patients to perform the operation remotely. The mitral valve was repaired in 117 and replaced in all other patients. The voice-controlled robotic arm (AESOP 3000) facilitated videoscopic-assisted mitral valve surgery. The procedure was completed without the need for an additional assistant as "solo surgery." Additional procedures like radiofrequency ablation and tricuspid valve repair were performed in 21 and 4 patients, respectively. Duration of bypass and clamp time was comparable to conventional procedures (107 A 34 and 50 A 16 min, respectively). Hospital mortality was 1.2%. Using the da Vinci telemanipulation system, remote mitral valve repair was successfully performed in 13 of 15 patients. Robotic-assisted less invasive mitral valve surgery has evolved to a reliable technique with reproducible results for primary operations and for reoperations. Robotic assistance has enabled a solo surgery approach. The combination with radiofrequency ablation (Mini Maze) in patients with chronic atrial fibrillation has proven to be beneficial. The use of telemanipulation systems for remote mitral valve surgery is promising, but a number of problems have to be solved before the introduction of a closed chest mitral valve procedure.

  1. Virtual modeling of robot-assisted manipulations in abdominal surgery.

    PubMed

    Berelavichus, Stanislav V; Karmazanovsky, Grigory G; Shirokov, Vadim S; Kubyshkin, Valeriy A; Kriger, Andrey G; Kondratyev, Evgeny V; Zakharova, Olga P

    2012-06-27

    To determine the effectiveness of using multidetector computed tomography (MDCT) data in preoperative planning of robot-assisted surgery. Fourteen patients indicated for surgery underwent MDCT using 64 and 256-slice MDCT. Before the examination, a specially constructed navigation net was placed on the patient's anterior abdominal wall. Processing of MDCT data was performed on a Brilliance Workspace 4 (Philips). Virtual vectors that imitate robotic and assistant ports were placed on the anterior abdominal wall of the 3D model of the patient, considering the individual anatomy of the patient and the technical capabilities of robotic arms. Sites for location of the ports were directed by projection on the roentgen-positive tags of the navigation net. There were no complications observed during surgery or in the post-operative period. We were able to reduce robotic arm interference during surgery. The surgical area was optimal for robotic and assistant manipulators without any need for reinstallation of the trocars. This method allows modeling of the main steps in robot-assisted intervention, optimizing operation of the manipulator and lowering the risk of injuries to internal organs.

  2. Protocol for concomitant temporomandibular joint custom-fitted total joint reconstruction and orthognathic surgery utilizing computer-assisted surgical simulation.

    PubMed

    Movahed, Reza; Teschke, Marcus; Wolford, Larry M

    2013-12-01

    Clinicians who address temporomandibular joint (TMJ) pathology and dentofacial deformities surgically can perform the surgery in 1 stage or 2 separate stages. The 2-stage approach requires the patient to undergo 2 separate operations and anesthesia, significantly prolonging the overall treatment. However, performing concomitant TMJ and orthognathic surgery (CTOS) in these cases requires careful treatment planning and surgical proficiency in the 2 surgical areas. This article presents a new treatment protocol for the application of computer-assisted surgical simulation in CTOS cases requiring reconstruction with patient-fitted total joint prostheses. The traditional and new CTOS protocols are described and compared. The new CTOS protocol helps decrease the preoperative workup time and increase the accuracy of model surgery. Copyright © 2013 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  3. Robot-assisted surgery: the future is here.

    PubMed

    Gerhardus, Diana

    2003-01-01

    According to L. Wiley Nifong, director of robotic surgery at East Carolina University's Brody School of Medicine, "Nationally, only one-fourth of the 15 million surgeries performed each year are done with small incisions or what doctors call 'minimally invasive surgery'." Robots could raise that number substantially (Stark 2002). Currently, healthcare organizations use robot technology for thoracic, abdominal, pelvic, and neurological surgical procedures. Minimally invasive surgery reduces the amount of inpatient hospital days, and the computer in the system filters any hand tremors a physician may have during the surgery. The use of robot-assisted surgery improves quality of care because the patient experiences less pain after the surgery. Robot-assisted surgery demonstrates definite advantages for the patient, physician, and hospital; however, healthcare organizations in the United States have yet to acquire the technology because of implementation costs and the lack of FDA (Food and Drug Administration) approval for using the technology for certain types of heart procedures. This article focuses on robot-assisted surgery advantages to patients, physicians, and hospitals as well as on the disadvantages to physicians. In addition, the article addresses implementation costs, which creates financial hurdles for most healthcare organizations; offers recommendations for administrators to embrace this technology for strategic positioning; and enumerates possible roles for robots in medicine.

  4. Virtual reality-assisted robotic surgery simulation.

    PubMed

    Albani, Justin M; Lee, David I

    2007-03-01

    For more than a decade, advancing computer technologies have allowed incorporation of virtual reality (VR) into surgical training. This has become especially important in training for laparoscopic procedures, which often are complex and leave little room for error. With the advent of robotic surgery and the development and prevalence of a commercial surgical system (da Vinci robot; Intuitive Surgical, Sunnyvale, CA), a valid VR-assisted robotic surgery simulator could minimize the steep learning curve associated with many of these complex procedures and thus enable better outcomes. To date, such simulation does not exist; however, several agencies and corporations are involved in making this dream a reality. We review the history and progress of VR simulation in surgical training, its promising applications in robotic-assisted surgery, and the remaining challenges to implementation.

  5. Computed Tomography-Assisted Thoracoscopic Surgery: A Novel, Innovative Approach in Patients With Deep Intrapulmonary Lesions of Unknown Malignant Status.

    PubMed

    Kostrzewa, Michael; Kara, Kerim; Rathmann, Nils; Tsagogiorgas, Charalambos; Henzler, Thomas; Schoenberg, Stefan O; Hohenberger, Peter; Diehl, Steffen J; Roessner, Eric D

    2017-06-01

    Minimally invasive resection of small, deep intrapulmonary lesions can be challenging due to the difficulty of localizing them during video-assisted thoracoscopic surgery (VATS). We report our preliminary results evaluating the feasibility of an image-guided, minimally invasive, 1-stop-shop approach for the resection of small, deep intrapulmonary lesions in a hybrid operating room (OR). Fifteen patients (5 men, 10 women; mean age, 63 years) with a total of 16 solitary, deep intrapulmonary nodules of unknown malignant status were identified for intraoperative wire marking. Patients were placed on the operating table for resection by VATS. A marking wire was placed within the lesion under 3D laser and fluoroscopic guidance using a cone beam computed tomography system. Then, wedge resection by VATS was performed in the same setting without repositioning the patient. Complete resection with adequate safety margins was confirmed for all lesions. Marking wire placement facilitated resection in 15 of 16 lesions. Eleven lesions proved to be malignant, either primary or secondary; 5 were benign. Mean lesion size was 7.7 mm; mean distance to the pleural surface was 15.1 mm (mean lesion depth-diameter ratio, 2.2). Mean procedural time for marking wire placement was 35 minutes; mean VATS duration was 36 minutes. Computed tomography-assisted thoracoscopic surgery is a new, safe, and effective procedure for minimally invasive resection of small, deeply localized intrapulmonary lesions. The benefits of computed tomography-assisted thoracoscopic surgery are 1. One-stop-shop procedure, 2. Lower risk for the patient (no patient relocation, no marking wire loss), and 3. No need to coordinate scheduling between the CT room and OR.

  6. An analysis of computer-assisted pre-screening prior to elective surgery.

    PubMed

    Grant, C; Ludbrook, G L; O'Loughlin, E J; Corcoran, T B

    2012-03-01

    In order to assess the potential utility of guided patient self-assessment as an early preoperative triage tool, a computer-assisted questionnaire delivered by a non-clinician via telephone was 1) compared to face-to-face interview and examination by anaesthetists in outpatient clinics and 2) evaluated as a mechanism to stream patients to day of surgery assessment. In total, 514 patients scheduled for elective surgery in two tertiary public hospitals were assessed initially by telephone and then in an outpatient clinic. Both forms of assessment were marked by panels of specialist anaesthetists, who also provided an opinion on which patients would have been suitable to bypass preoperative anaesthetic outpatient assessment based upon information provided by the telephone interview. Overall, the quality of assessment provided by non-clinician telephone interview was comparable to face-to-face interview by anaesthetists, although more complex issues required face-to-face assessment. Panel review considered that 398 patients (60%) would not have required evaluation by an anaesthetist until the day of surgery, thus avoiding the need to separately attend a preoperative outpatient clinic. The sensitivity of telephone interview provided information to correctly classify patients as suitable for day of surgery evaluation was 98% (95% confidence interval 96 to 99%) with a specificity of 97% (95% confidence interval 92 to 98%). This study demonstrates that remote computer-assisted assessment can produce quality patient health information and enable early patient work-up and triage with the potential to reduce costs through more efficient use of resources.

  7. [Impact of digital technology on clinical practices: perspectives from surgery].

    PubMed

    Zhang, Y; Liu, X J

    2016-04-09

    Digital medical technologies or computer aided medical procedures, refer to imaging, 3D reconstruction, virtual design, 3D printing, navigation guided surgery and robotic assisted surgery techniques. These techniques are integrated into conventional surgical procedures to create new clinical protocols that are known as "digital surgical techniques". Conventional health care is characterized by subjective experiences, while digital medical technologies bring quantifiable information, transferable data, repeatable methods and predictable outcomes into clinical practices. Being integrated into clinical practice, digital techniques facilitate surgical care by improving outcomes and reducing risks. Digital techniques are becoming increasingly popular in trauma surgery, orthopedics, neurosurgery, plastic and reconstructive surgery, imaging and anatomic sciences. Robotic assisted surgery is also evolving and being applied in general surgery, cardiovascular surgery and orthopedic surgery. Rapid development of digital medical technologies is changing healthcare and clinical practices. It is therefore important for all clinicians to purposefully adapt to these technologies and improve their clinical outcomes.

  8. Computer-assisted neurosurgical navigational system for transsphenoidal surgery--technical note.

    PubMed

    Onizuka, M; Tokunaga, Y; Shibayama, A; Miyazaki, H

    2001-11-01

    Transsphenoidal surgery carries the risk of carotid artery injury even for very experienced neurosurgeons. The computer-assisted neurosurgical (CANS) navigational system was used to obtain more precise guidance, based on the axial and coronal images during the transsphenoidal approach for nine pituitary adenomas. The CANS navigator consists of a three-dimensional digitizer, a computer, and a graphic unit, which utilizes electromagnetic coupling technology to detect the spatial position of a suction tube attached to a magnetic sensor. Preoperatively, the magnetic resonance images are transferred and stored in the computer and the tip of the suction tube is shown on a real-time basis superimposed on the preoperative images. The CANS navigation system correctly displayed the surgical orientation and provided localization in all nine patients. No intraoperative complications were associated with the use of this system. However, outflow of cerebrospinal fluid during tumor removal may affect the accuracy, so the position of the probe when the tumor is removed must be accurately determined. The CANS navigator enables precise localization of the suction tube during the transsphenoidal approach and allows safer and less-invasive surgery.

  9. Mechatronics Interface for Computer Assisted Prostate Surgery Training

    NASA Astrophysics Data System (ADS)

    Altamirano del Monte, Felipe; Padilla Castañeda, Miguel A.; Arámbula Cosío, Fernando

    2006-09-01

    In this work is presented the development of a mechatronics device to simulate the interaction of the surgeon with the surgical instrument (resectoscope) used during a Transurethral Resection of the Prostate (TURP). Our mechatronics interface is part of a computer assisted system for training in TURP, which is based on a 3D graphics model of the prostate which can be deformed and resected interactively by the user. The mechatronics interface, is the device that the urology residents will manipulate to simulate the movements performed during surgery. Our current prototype has five degrees of freedom, which are enough to have a realistic simulation of the surgery movements. Two of these degrees of freedom are linear, to determinate the linear displacement of the resecting loop and the other three are rotational to determinate three directions and amounts of rotation.

  10. Orbital and maxillofacial computer aided surgery: patient-specific finite element models to predict surgical outcomes.

    PubMed

    Luboz, Vincent; Chabanas, Matthieu; Swider, Pascal; Payan, Yohan

    2005-08-01

    This paper addresses an important issue raised for the clinical relevance of Computer-Assisted Surgical applications, namely the methodology used to automatically build patient-specific finite element (FE) models of anatomical structures. From this perspective, a method is proposed, based on a technique called the mesh-matching method, followed by a process that corrects mesh irregularities. The mesh-matching algorithm generates patient-specific volume meshes from an existing generic model. The mesh regularization process is based on the Jacobian matrix transform related to the FE reference element and the current element. This method for generating patient-specific FE models is first applied to computer-assisted maxillofacial surgery, and more precisely, to the FE elastic modelling of patient facial soft tissues. For each patient, the planned bone osteotomies (mandible, maxilla, chin) are used as boundary conditions to deform the FE face model, in order to predict the aesthetic outcome of the surgery. Seven FE patient-specific models were successfully generated by our method. For one patient, the prediction of the FE model is qualitatively compared with the patient's post-operative appearance, measured from a computer tomography scan. Then, our methodology is applied to computer-assisted orbital surgery. It is, therefore, evaluated for the generation of 11 patient-specific FE poroelastic models of the orbital soft tissues. These models are used to predict the consequences of the surgical decompression of the orbit. More precisely, an average law is extrapolated from the simulations carried out for each patient model. This law links the size of the osteotomy (i.e. the surgical gesture) and the backward displacement of the eyeball (the consequence of the surgical gesture).

  11. [Treatment of pelvic Ewing's sarcoma in children and the effect on the skeletal growth and development].

    PubMed

    Fu, Jun; Guo, Zheng; Wang, Zhen; Li, Xiang-dong; Li, Jing; Chen, Guo-jing; Wu, Zhi-gang

    2012-12-01

    To explore the effect of neo-adjuvant chemotherapy and computer-assisted surgery on children and adolescents with primary pelvic Ewing's sarcoma, and assess the therapeutic effect on the pelvic skeletal growth and development. This is a retrospective analysis of 10 children with primary pelvic Ewing's sarcoma treated between Jan 2001 and Oct 2010 at the Department of Oncologic Orthopaedics at Xijing Hospital. There were 3 girls and 7 boys in the age of 7 to 16 years (average 12.7 years). All patients were pathologically diagnosed as Ewing's sarcoma. There were two cases in the sacroiliac joint, one in the ilium, one in the pubic bone, and 6 cases in peri-acetabular area including 5 below the triradiate cartilage and one above the triradiate cartilage, without cartilage invasion. All patients underwent neo-adjuvant chemotherapy, resection and reconstruction surgery and postoperative chemotherapy. CDP, ADM and IFO regimen chemotherapy were given as the main treatment. Five cases were treated by traditional resection and reconstruction, and after 2008, five cases were treated by computer-assisted surgery. During the reconstruction, the hip rotation center was put at a depressed location. All of the 10 cases underwent postoperative radiotherapy in a dose of 45-55 Gy. All patients were followed-up for 12-72 months (mean: 37.8 months). One child had tumor recurrence and lung metastasis and 9 patients had no evidence of disease (NED). After neo-adjuvant chemotherapy, the oncologic statuses (RECIST) were: 1 CR, 8 PR and 1 SD. The functional recoveries after surgery (Enneking's) were: 4 cases excellent, 4 good, 1 fair and 1 poor. Five cases who underwent computer-assisted surgery achieved a good reconstruction without local recurrence. There were no effects on skeletal growth in 8 cases. An unbalanced hip rotational center occurred in one case, and a compemsatory scoliosis was found in another case. There were no serious complications in all patients. The comprehensive treatment including neo-adjuvant chemotherapy, resection-reconstruction surgery and postoperative chemoradiotherapy may give a good control to primary pelvic Ewing's sarcomas in children and adolescents. The computer-assisted surgery used for accurate tumor resection and pelvic reconstruction is a good alternative when treating young patients with malignant pelvic tumors. The triradiate cartilage in children's acetabulum could be a natural barrier resistant to the invasion of Ewing's sarcomas.

  12. Accuracy analysis of pedicle screw placement in posterior scoliosis surgery: comparison between conventional fluoroscopic and computer-assisted technique.

    PubMed

    Kotani, Yoshihisa; Abumi, Kuniyoshi; Ito, Manabu; Takahata, Masahiko; Sudo, Hideki; Ohshima, Shigeki; Minami, Akio

    2007-06-15

    The accuracy of pedicle screw placement was evaluated in posterior scoliosis surgeries with or without the use of computer-assisted surgical techniques. In this retrospective cohort study, the pedicle screw placement accuracy in posterior scoliosis surgery was compared between conventional fluoroscopic and computer-assisted surgical techniques. There has been no study systemically analyzing the perforation pattern and comparative accuracy of pedicle screw placement in posterior scoliosis surgery. The 45 patients who received posterior correction surgeries were divided into 2 groups: Group C, manual control (25 patients); and Group N, navigation surgery (20 patients). The average Cobb angles were 73.7 degrees and 73.1 degrees before surgery in Group C and Group N, respectively. Using CT images, vertebral rotation, pedicle axes as measured to anteroposterior sacral axis and vertebral axis, and insertion angle error were measured. In perforation cases, the angular tendency, insertion point, and length abnormality were evaluated. The perforation was observed in 11% of Group C and 1.8% in Group N. In Group C, medial perforations of left screws were demonstrated in 8 of 9 perforated screws and 55% were distributed either in L1 or T12. The perforation consistently occurred in pedicles in which those axes approached anteroposterior sacral axis within 5 degrees . The average insertion errors were 8.4 degrees and 5.0 degrees in Group C and Group N, respectively, which were significantly different (P < 0.02). The medial perforation in Group C occurred around L1, especially when pedicle axis approached anteroposterior sacral axis. This consistent tendency was considered as the limitation of fluoroscopic screw insertion in which horizontal vertebral image was not visible. The use of surgical navigation system successfully reduced the perforation rate and insertion angle errors, demonstrating the clear advantage in safe and accurate pedicle screw placement of scoliosis surgery.

  13. Comparison of computer-assisted surgery with conventional technique for the treatment of axial distal phalanx fractures in horses: an in vitro study.

    PubMed

    Andritzky, Juliane; Rossol, Melanie; Lischer, Christoph; Auer, Joerg A

    2005-01-01

    To compare the precision obtained with computer-assisted screw insertion for treatment of mid-sagittal articular fractures of the distal phalanx (P3) with results achieved with a conventional technique. In vitro experimental study. Thirty-two cadaveric equine limbs. Four groups of 8 limbs were studied. Either 1 or 2 screws were inserted perpendicular to an imaginary axial fracture of P3 using computer-assisted surgery (CAS) or conventional technique. Screw insertion time, predetermined screw length, inserted screw length, fit of the screw, and errors in placement were recorded. CAS technique took 15-20 minutes longer but resulted in greater precision of screw length and placement compared with the conventional technique. Improved precision in screw insertion with CAS makes insertion of 2 screws possible for repair of mid-sagittal P3 fractures. CAS although expensive improves precision in screw insertion into P3 and consequently should yield improved clinical outcome.

  14. Computer-Assisted Orthopedic Surgery: Current State and Future Perspective

    PubMed Central

    Zheng, Guoyan; Nolte, Lutz P.

    2015-01-01

    Introduced about two decades ago, computer-assisted orthopedic surgery (CAOS) has emerged as a new and independent area, due to the importance of treatment of musculoskeletal diseases in orthopedics and traumatology, increasing availability of different imaging modalities, and advances in analytics and navigation tools. The aim of this paper is to present the basic elements of CAOS devices and to review state-of-the-art examples of different imaging modalities used to create the virtual representations, of different position tracking devices for navigation systems, of different surgical robots, of different methods for registration and referencing, and of CAOS modules that have been realized for different surgical procedures. Future perspectives will also be outlined. PMID:26779486

  15. Computer Assisted Surgery and Current Trends in Orthopaedics Research and Total Joint Replacements

    NASA Astrophysics Data System (ADS)

    Amirouche, Farid

    2008-06-01

    Musculoskeletal research has brought about revolutionary changes in our ability to perform high precision surgery in joint replacement procedures. Recent advances in computer assisted surgery as well better materials have lead to reduced wear and greatly enhanced the quality of life of patients. The new surgical techniques to reduce the size of the incision and damage to underlying structures have been the primary advance toward this goal. These new techniques are known as MIS or Minimally Invasive Surgery. Total hip and knee Arthoplasties are at all time high reaching 1.2 million surgeries per year in the USA. Primary joint failures are usually due to osteoarthristis, rheumatoid arthritis, osteocronis and other inflammatory arthritis conditions. The methods for THR and TKA are critical to initial stability and longevity of the prostheses. This research aims at understanding the fundamental mechanics of the joint Arthoplasty and providing an insight into current challenges in patient specific fitting, fixing, and stability. Both experimental and analytical work will be presented. We will examine Cementless total hip arthroplasty success in the last 10 years and how computer assisted navigation is playing in the follow up studies. Cementless total hip arthroplasty attains permanent fixation by the ingrowth of bone into a porous coated surface. Loosening of an ingrown total hip arthroplasty occurs as a result of osteolysis of the periprosthetic bone and degradation of the bone prosthetic interface. The osteolytic process occurs as a result of polyethylene wear particles produced by the metal polyethylene articulation of the prosthesis. The total hip arthroplasty is a congruent joint and the submicron wear particles produced are phagocytized by macrophages initiating an inflammatory cascade. This cascade produces cytokines ultimately implicated in osteolysis. Resulting bone loss both on the acetabular and femoral sides eventually leads to component instability. As patients are living longer and total hip arthroplasty is performed in younger patients the risks of osteolysis associated with cumulative wear is increased. Computer-assisted surgery is based on sensing feedback; vision and imaging that help surgeons align the patient's joints during total knee or hip replacement with a degree of accuracy not possible with the naked eye. For the first time, the computer feedback is essential for ligament balancing and longevity of the implants. The computers navigation systems also help surgeons to use smaller incisions instead of the traditional larger openings. Small-incision surgery offers the potential for faster recovery, less bleeding and less pain for patients. The development of SESCAN imaging technique to create a patient based model of a 3D joint will be presented to show the effective solution of complex geometry of joints.

  16. Computer-assisted hip and knee arthroplasty. Navigation and active robotic systems: an evidence-based analysis.

    PubMed

    2004-01-01

    The Medical Advisory Secretariat undertook a review of the evidence on the effectiveness and cost-effectiveness of computer assisted hip and knee arthroplasty. The two computer assisted arthroplasty systems that are the topics of this review are (1) navigation and (2) robotic-assisted hip and knee arthroplasty. Computer-assisted arthroplasty consists of navigation and robotic systems. Surgical navigation is a visualization system that provides positional information about surgical tools or implants relative to a target bone on a computer display. Most of the navigation-assisted arthroplasty devices that are the subject of this review are licensed by Health Canada. Robotic systems are active robots that mill bone according to information from a computer-assisted navigation system. The robotic-assisted arthroplasty devices that are the subject of this review are not currently licensed by Health Canada. The Cochrane and International Network of Agencies for Health Technology Assessment databases did not identify any health technology assessments on navigation or robotic-assisted hip or knee arthroplasty. The MEDLINE and EMBASE databases were searched for articles published between January 1, 1996 and November 30, 2003. This search produced 367 studies, of which 9 met the inclusion criteria. NAVIGATION-ASSISTED ARTHROPLASTY: Five studies were identified that examined navigation-assisted arthroplasty.A Level 1 evidence study from Germany found a statistically significant difference in alignment and angular deviation between navigation-assisted and free-hand total knee arthroplasty in favour of navigation-assisted surgery. However, the endpoints in this study were short-term. To date, the long-term effects (need for revision, implant longevity, pain, functional performance) are unknown.(1)A Level 2 evidence short-term study found that navigation-assisted total knee arthroplasty was significantly better than a non-navigated procedure for one of five postoperative measured angles.(2)A Level 2 evidence short-term study found no statistically significant difference in the variation of the abduction angle between navigation-assisted and conventional total hip arthroplasty.(3)Level 3 evidence observational studies of navigation-assisted total knee arthroplasty and unicompartmental knee arthroplasty have been conducted. Two studies reported that "the follow-up of the navigated prostheses is currently too short to know if clinical outcome or survival rates are improved. Longer follow-up is required to determine the respective advantages and disadvantages of both techniques."(4;5) ROBOTIC-ASSISTED ARTHROPLASTY: Four studies were identified that examined robotic-assisted arthroplasty.A Level 1 evidence study revealed that there was no statistically significant difference between functional hip scores at 24 months post implantation between patients who underwent robotic-assisted primary hip arthroplasty and those that were treated with manual implantation.(6)Robotic-assisted arthroplasty had advantages in terms of preoperative planning and the accuracy of the intraoperative procedure.(6)Patients who underwent robotic-assisted hip arthroplasty had a higher dislocation rate and more revisions.(6)Robotic-assisted arthroplasty may prove effective with certain prostheses (e.g., anatomic) because their use may result in less muscle detachment.(6)An observational study (Level 3 evidence) found that the incidence of severe embolic events during hip relocation was lower with robotic arthroplasty than with manual surgery.(7)An observational study (Level 3 evidence) found that there was no significant difference in gait analyses of patients who underwent robotic-assisted total hip arthroplasty using robotic surgery compared to patients who were treated with conventional cementless total hip arthroplasty.(8)An observational study (Level 3 evidence) compared outcomes of total knee arthroplasty between patients undergoing robotic surgery and patients who were historical controls. Brief, qualitative results suggested that there was much broader variation of angles after manual total knee arthroplasty compared to the robotic technique and that there was no difference in knee functional scores or implant position at the 3 and 6 month follow-up.(9).

  17. Computer-Assisted Hip and Knee Arthroplasty. Navigation and Active Robotic Systems

    PubMed Central

    2004-01-01

    Executive Summary Objective The Medical Advisory Secretariat undertook a review of the evidence on the effectiveness and cost-effectiveness of computer assisted hip and knee arthroplasty. The two computer assisted arthroplasty systems that are the topics of this review are (1) navigation and (2) robotic-assisted hip and knee arthroplasty. The Technology Computer-assisted arthroplasty consists of navigation and robotic systems. Surgical navigation is a visualization system that provides positional information about surgical tools or implants relative to a target bone on a computer display. Most of the navigation-assisted arthroplasty devices that are the subject of this review are licensed by Health Canada. Robotic systems are active robots that mill bone according to information from a computer-assisted navigation system. The robotic-assisted arthroplasty devices that are the subject of this review are not currently licensed by Health Canada. Review Strategy The Cochrane and International Network of Agencies for Health Technology Assessment databases did not identify any health technology assessments on navigation or robotic-assisted hip or knee arthroplasty. The MEDLINE and EMBASE databases were searched for articles published between January 1, 1996 and November 30, 2003. This search produced 367 studies, of which 9 met the inclusion criteria. Summary of Findings Navigation-Assisted Arthroplasty Five studies were identified that examined navigation-assisted arthroplasty. A Level 1 evidence study from Germany found a statistically significant difference in alignment and angular deviation between navigation-assisted and free-hand total knee arthroplasty in favour of navigation-assisted surgery. However, the endpoints in this study were short-term. To date, the long-term effects (need for revision, implant longevity, pain, functional performance) are unknown.(1) A Level 2 evidence short-term study found that navigation-assisted total knee arthroplasty was significantly better than a non-navigated procedure for one of five postoperative measured angles.(2) A Level 2 evidence short-term study found no statistically significant difference in the variation of the abduction angle between navigation-assisted and conventional total hip arthroplasty.(3) Level 3 evidence observational studies of navigation-assisted total knee arthroplasty and unicompartmental knee arthroplasty have been conducted. Two studies reported that “the follow-up of the navigated prostheses is currently too short to know if clinical outcome or survival rates are improved. Longer follow-up is required to determine the respective advantages and disadvantages of both techniques.”(4;5) Robotic-Assisted Arthroplasty Four studies were identified that examined robotic-assisted arthroplasty. A Level 1 evidence study revealed that there was no statistically significant difference between functional hip scores at 24 months post implantation between patients who underwent robotic-assisted primary hip arthroplasty and those that were treated with manual implantation.(6) Robotic-assisted arthroplasty had advantages in terms of preoperative planning and the accuracy of the intraoperative procedure.(6) Patients who underwent robotic-assisted hip arthroplasty had a higher dislocation rate and more revisions.(6) Robotic-assisted arthroplasty may prove effective with certain prostheses (e.g., anatomic) because their use may result in less muscle detachment.(6) An observational study (Level 3 evidence) found that the incidence of severe embolic events during hip relocation was lower with robotic arthroplasty than with manual surgery.(7) An observational study (Level 3 evidence) found that there was no significant difference in gait analyses of patients who underwent robotic-assisted total hip arthroplasty using robotic surgery compared to patients who were treated with conventional cementless total hip arthroplasty.(8) An observational study (Level 3 evidence) compared outcomes of total knee arthroplasty between patients undergoing robotic surgery and patients who were historical controls. Brief, qualitative results suggested that there was much broader variation of angles after manual total knee arthroplasty compared to the robotic technique and that there was no difference in knee functional scores or implant position at the 3 and 6 month follow-up.(9) PMID:23074452

  18. Development and refinement of computer-assisted planning and execution system for use in face-jaw-teeth transplantation to improve skeletal and dento-occlusal outcomes.

    PubMed

    Hashemi, Sepehr; Armand, Mehran; Gordon, Chad R

    2016-10-01

    To describe the development and refinement of the computer-assisted planning and execution (CAPE) system for use in face-jaw-teeth transplants (FJTTs). Although successful, some maxillofacial transplants result in suboptimal hybrid occlusion and may require subsequent surgical orthognathic revisions. Unfortunately, the use of traditional dental casts and splints pose several compromising shortcomings in the context of FJTT and hybrid occlusion. Computer-assisted surgery may overcome these challenges. Therefore, the use of computer-assisted orthognathic techniques and functional planning may prevent the need for such revisions and improve facial-skeletal outcomes. A comprehensive CAPE system for use in FJTT was developed through a multicenter collaboration and refined using plastic models, live miniature swine surgery, and human cadaver models. The system marries preoperative surgical planning and intraoperative execution by allowing on-table navigation of the donor fragment relative to recipient cranium, and real-time reporting of patient's cephalometric measurements relative to a desired dental-skeletal outcome. FJTTs using live-animal and cadaveric models demonstrate the CAPE system to be accurate in navigation and beneficial in improving hybrid occlusion and other craniofacial outcomes. Future refinement of the CAPE system includes integration of more commonly performed orthognathic/maxillofacial procedures.

  19. Planning and simulation of medical robot tasks.

    PubMed

    Raczkowsky, J; Bohner, P; Burghart, C; Grabowski, H

    1998-01-01

    Complex techniques for planning and performing surgery revolutionize medical interventions. In former times preoperative planning of interventions usually took place in the surgeons mind. Today's new computer techniques allow the surgeon to discuss various operation methods for a patient and to visualize them three-dimensionally. The use of computer assisted surgical planning helps to get better results of a treatment and supports the surgeon before and during the surgical intervention. In this paper we are presenting our planning and simulation system for operations in maxillo-facial surgery. All phases of a surgical intervention are supported. Chapter 1 gives a description of the medical motivation for our planning system and its environment. In Chapter 2 the basic components are presented. The planning system is depicted in Chapter 3 and a simulation of a robot assisted surgery can be found in Chapter 4. Chapter 5 concludes the paper and gives a survey about our future work.

  20. Importance of preoperative imaging with 64-row three-dimensional multidetector computed tomography for safer video-assisted thoracic surgery in lung cancer.

    PubMed

    Akiba, Tadashi; Marushima, Hideki; Harada, Junta; Kobayashi, Susumu; Morikawa, Toshiaki

    2009-01-01

    Video-assisted thoracic surgery (VATS) has recently been adopted for complicated anatomical lung resections. During these thoracoscopic procedures, surgeons view the operative field on a two-dimensional (2-D) video monitor and cannot palpate the organ directly, thus frequently encountering anatomical difficulties. This study aimed to estimate the usefulness of preoperative three-dimensional (3-D) imaging of thoracic organs. We compared the preoperative 64-row three-dimensional multidetector computed tomography (3DMDCT) findings of lung cancer-affected thoracic organs to the operative findings. In comparison to the operative findings, the branches of pulmonary arteries, veins, and bronchi were well defined in the 3D-MDCT images of 27 patients. 3D-MDCT imaging is useful for preoperatively understanding the individual thoracic anatomy in lung cancer surgery. This modality can therefore contribute to safer anatomical pulmonary operations, especially in VATS.

  1. Robotic-Assisted Knee Arthroplasty: An Overview.

    PubMed

    van der List, Jelle P; Chawla, Harshvardhan; Pearle, Andrew D

    2016-01-01

    Unicompartmental knee arthroplasty and total knee arthroplasty are reliable treatment options for osteoarthritis. In order to improve survivorship rates, variables that are intraoperatively controlled by the orthopedic surgeon are being evaluated. These variables include lower leg alignment, soft tissue balance, joint line maintenance, and tibial and femoral component alignment, size, and fixation methods. Since tighter control of these factors is associated with improved outcomes of knee arthroplasty, several computer-assisted surgery systems have been developed. These systems differ in the number and type of variables they control. Robotic-assisted systems control these aforementioned variables and, in addition, aim to improve the surgical precision of the procedure. Robotic-assisted systems are active, semi-active, or passive, depending on how independently the systems perform maneuvers. Reviewing the robotic-assisted knee arthroplasty systems, it becomes clear that these systems can accurately and reliably control the aforementioned variables. Moreover, these systems are more accurate and reliable in controlling these variables when compared to the current gold standard of conventional manual surgery. At present, few studies have assessed the survivorship and functional outcomes of robotic-assisted surgery, and no sufficiently powered studies were identified that compared survivorship or functional outcomes between robotic-assisted and conventional knee arthroplasty. Although preliminary outcomes of robotic-assisted surgery look promising, more studies are necessary to assess if the increased accuracy and reliability in controlling the surgical variables leads to better outcomes of robotic-assisted knee arthroplasty.

  2. Navigation and Robotics in Spinal Surgery: Where Are We Now?

    PubMed

    Overley, Samuel C; Cho, Samuel K; Mehta, Ankit I; Arnold, Paul M

    2017-03-01

    Spine surgery has experienced much technological innovation over the past several decades. The field has seen advancements in operative techniques, implants and biologics, and equipment such as computer-assisted navigation and surgical robotics. With the arrival of real-time image guidance and navigation capabilities along with the computing ability to process and reconstruct these data into an interactive three-dimensional spinal "map", so too have the applications of surgical robotic technology. While spinal robotics and navigation represent promising potential for improving modern spinal surgery, it remains paramount to demonstrate its superiority as compared to traditional techniques prior to assimilation of its use amongst surgeons.The applications for intraoperative navigation and image-guided robotics have expanded to surgical resection of spinal column and intradural tumors, revision procedures on arthrodesed spines, and deformity cases with distorted anatomy. Additionally, these platforms may mitigate much of the harmful radiation exposure in minimally invasive surgery to which the patient, surgeon, and ancillary operating room staff are subjected.Spine surgery relies upon meticulous fine motor skills to manipulate neural elements and a steady hand while doing so, often exploiting small working corridors utilizing exposures that minimize collateral damage. Additionally, the procedures may be long and arduous, predisposing the surgeon to both mental and physical fatigue. In light of these characteristics, spine surgery may actually be an ideal candidate for the integration of navigation and robotic-assisted procedures.With this paper, we aim to critically evaluate the current literature and explore the options available for intraoperative navigation and robotic-assisted spine surgery. Copyright © 2016 by the Congress of Neurological Surgeons.

  3. Report on First International Workshop on Robotic Surgery in Thoracic Oncology.

    PubMed

    Veronesi, Giulia; Cerfolio, Robert; Cingolani, Roberto; Rueckert, Jens C; Soler, Luc; Toker, Alper; Cariboni, Umberto; Bottoni, Edoardo; Fumagalli, Uberto; Melfi, Franca; Milli, Carlo; Novellis, Pierluigi; Voulaz, Emanuele; Alloisio, Marco

    2016-01-01

    A workshop of experts from France, Germany, Italy, and the United States took place at Humanitas Research Hospital Milan, Italy, on February 10 and 11, 2016, to examine techniques for and applications of robotic surgery to thoracic oncology. The main topics of presentation and discussion were robotic surgery for lung resection; robot-assisted thymectomy; minimally invasive surgery for esophageal cancer; new developments in computer-assisted surgery and medical applications of robots; the challenge of costs; and future clinical research in robotic thoracic surgery. The following article summarizes the main contributions to the workshop. The Workshop consensus was that since video-assisted thoracoscopic surgery (VATS) is becoming the mainstream approach to resectable lung cancer in North America and Europe, robotic surgery for thoracic oncology is likely to be embraced by an increasing numbers of thoracic surgeons, since it has technical advantages over VATS, including intuitive movements, tremor filtration, more degrees of manipulative freedom, motion scaling, and high-definition stereoscopic vision. These advantages may make robotic surgery more accessible than VATS to trainees and experienced surgeons and also lead to expanded indications. However, the high costs of robotic surgery and absence of tactile feedback remain obstacles to widespread dissemination. A prospective multicentric randomized trial (NCT02804893) to compare robotic and VATS approaches to stages I and II lung cancer will start shortly.

  4. Is computer navigation when used in the surgery of iliosacral pelvic bone tumours safer for the patient?

    PubMed

    Laitinen, M K; Parry, M C; Albergo, J I; Grimer, R J; Jeys, L M

    2017-02-01

    Due to the complex anatomy of the pelvis, limb-sparing resections of pelvic tumours achieving adequate surgical margins, can often be difficult. The advent of computer navigation has improved the precision of resection of these lesions, though there is little evidence comparing resection with or without the assistance of navigation. Our aim was to evaluate the efficacy of navigation-assisted surgery for the resection of pelvic bone tumours involving the posterior ilium and sacrum. Using our prospectively updated institutional database, we conducted a retrospective case control study of 21 patients who underwent resection of the posterior ilium and sacrum, for the treatment of a primary sarcoma of bone, between 1987 and 2015. The resection was performed with the assistance of navigation in nine patients and without navigation in 12. We assessed the accuracy of navigation-assisted surgery, as defined by the surgical margin and how this affects the rate of local recurrence, the disease-free survival and the effects on peri-and post-operative morbidity. The mean age of the patients was 36.4 years (15 to 66). The mean size of the tumour was 10.9 cm. In the navigation-assisted group, the margin was wide in two patients (16.7%), marginal in six (66.7%) and wide-contaminated in one (11.1%) with no intralesional margin. In the non-navigated-assisted group; the margin was wide in two patients (16.7%), marginal in five (41.7%), intralesional in three (25.0%) and wide-contaminated in two (16.7%). Local recurrence occurred in two patients in the navigation-assisted group (22.2%) and six in the non-navigation-assisted group (50.0%). The disease-free survival was significantly better when operated with navigation-assistance (p = 0.048). The blood loss and operating time were less in the navigated-assisted group, as was the risk of a foot drop post-operatively. The introduction of navigation-assisted surgery for the resection of tumours of the posterior ilium and sacrum has increased the safety for the patients and allows for a better oncological outcome. Cite this article: Bone Joint J 2017;99-B:261-6. ©2017 The British Editorial Society of Bone & Joint Surgery.

  5. Application of advanced virtual reality and 3D computer assisted technologies in tele-3D-computer assisted surgery in rhinology.

    PubMed

    Klapan, Ivica; Vranjes, Zeljko; Prgomet, Drago; Lukinović, Juraj

    2008-03-01

    The real-time requirement means that the simulation should be able to follow the actions of the user that may be moving in the virtual environment. The computer system should also store in its memory a three-dimensional (3D) model of the virtual environment. In that case a real-time virtual reality system will update the 3D graphic visualization as the user moves, so that up-to-date visualization is always shown on the computer screen. Upon completion of the tele-operation, the surgeon compares the preoperative and postoperative images and models of the operative field, and studies video records of the procedure itself Using intraoperative records, animated images of the real tele-procedure performed can be designed. Virtual surgery offers the possibility of preoperative planning in rhinology. The intraoperative use of computer in real time requires development of appropriate hardware and software to connect medical instrumentarium with the computer and to operate the computer by thus connected instrumentarium and sophisticated multimedia interfaces.

  6. Computer Assisted Navigation in Knee Arthroplasty

    PubMed Central

    Bae, Dae Kyung

    2011-01-01

    Computer assisted surgery (CAS) was used to improve the positioning of implants during total knee arthroplasty (TKA). Most studies have reported that computer assisted navigation reduced the outliers of alignment and component malpositioning. However, additional sophisticated studies are necessary to determine if the improvement of alignment will improve long-term clinical results and increase the survival rate of the implant. Knowledge of CAS-TKA technology and understanding the advantages and limitations of navigation are crucial to the successful application of the CAS technique in TKA. In this article, we review the components of navigation, classification of the system, surgical method, potential error, clinical results, advantages, and disadvantages. PMID:22162787

  7. The Role of Computer-Assisted Technology in Post-Traumatic Orbital Reconstruction: A PRISMA-driven Systematic Review.

    PubMed

    Wan, Kelvin H; Chong, Kelvin K L; Young, Alvin L

    2015-12-08

    Post-traumatic orbital reconstruction remains a surgical challenge and requires careful preoperative planning, sound anatomical knowledge and good intraoperative judgment. Computer-assisted technology has the potential to reduce error and subjectivity in the management of these complex injuries. A systematic review of the literature was conducted to explore the emerging role of computer-assisted technologies in post-traumatic orbital reconstruction, in terms of functional and safety outcomes. We searched for articles comparing computer-assisted procedures with conventional surgery and studied outcomes on diplopia, enophthalmos, or procedure-related complications. Six observational studies with 273 orbits at a mean follow-up of 13 months were included. Three out of 4 studies reported significantly fewer patients with residual diplopia in the computer-assisted group, while only 1 of the 5 studies reported better improvement in enophthalmos in the assisted group. Types and incidence of complications were comparable. Study heterogeneities limiting statistical comparison by meta-analysis will be discussed. This review highlights the scarcity of data on computer-assisted technology in orbital reconstruction. The result suggests that computer-assisted technology may offer potential advantage in treating diplopia while its role remains to be confirmed in enophthalmos. Additional well-designed and powered randomized controlled trials are much needed.

  8. From medical images to minimally invasive intervention: Computer assistance for robotic surgery.

    PubMed

    Lee, Su-Lin; Lerotic, Mirna; Vitiello, Valentina; Giannarou, Stamatia; Kwok, Ka-Wai; Visentini-Scarzanella, Marco; Yang, Guang-Zhong

    2010-01-01

    Minimally invasive surgery has been established as an important way forward in surgery for reducing patient trauma and hospitalization with improved prognosis. The introduction of robotic assistance enhances the manual dexterity and accuracy of instrument manipulation. Further development of the field in using pre- and intra-operative imaging guidance requires the integration of the general anatomy of the patient with clear pathologic indications and geometrical information for preoperative planning and intra-operative manipulation. It also requires effective visualization and the recreation of haptic and tactile sensing with dynamic active constraints to improve consistency and safety of the surgical procedures. This paper describes key technical considerations of tissue deformation tracking, 3D reconstruction, subject-specific modeling, image guidance and augmented reality for robotic assisted minimally invasive surgery. It highlights the importance of adapting preoperative surgical planning according to intra-operative data and illustrates how dynamic information such as tissue deformation can be incorporated into the surgical navigation framework. Some of the recent trends are discussed in terms of instrument design and the usage of dynamic active constraints and human-robot perceptual docking for robotic assisted minimally invasive surgery. Copyright 2009 Elsevier Ltd. All rights reserved.

  9. Computational Planning in Facial Surgery.

    PubMed

    Zachow, Stefan

    2015-10-01

    This article reflects the research of the last two decades in computational planning for cranio-maxillofacial surgery. Model-guided and computer-assisted surgery planning has tremendously developed due to ever increasing computational capabilities. Simulators for education, planning, and training of surgery are often compared with flight simulators, where maneuvers are also trained to reduce a possible risk of failure. Meanwhile, digital patient models can be derived from medical image data with astonishing accuracy and thus can serve for model surgery to derive a surgical template model that represents the envisaged result. Computerized surgical planning approaches, however, are often still explorative, meaning that a surgeon tries to find a therapeutic concept based on his or her expertise using computational tools that are mimicking real procedures. Future perspectives of an improved computerized planning may be that surgical objectives will be generated algorithmically by employing mathematical modeling, simulation, and optimization techniques. Planning systems thus act as intelligent decision support systems. However, surgeons can still use the existing tools to vary the proposed approach, but they mainly focus on how to transfer objectives into reality. Such a development may result in a paradigm shift for future surgery planning. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  10. A combination of three-dimensional printing and computer-assisted virtual surgical procedure for preoperative planning of acetabular fracture reduction.

    PubMed

    Zeng, Canjun; Xing, Weirong; Wu, Zhanglin; Huang, Huajun; Huang, Wenhua

    2016-10-01

    Treatment of acetabular fractures remains one of the most challenging tasks that orthopaedic surgeons face. An accurate assessment of the injuries and preoperative planning are essential for an excellent reduction. The purpose of this study was to evaluate the feasibility, accuracy and effectiveness of performing 3D printing technology and computer-assisted virtual surgical procedures for preoperative planning in acetabular fractures. We hypothesised that more accurate preoperative planning using 3D printing models will reduce the operation time and significantly improve the outcome of acetabular fracture repair. Ten patients with acetabular fractures were recruited prospectively and examined by CT scanning. A 3-D model of each acetabular fracture was reconstructed with MIMICS14.0 software from the DICOM file of the CT data. Bone fragments were moved and rotated to simulate fracture reduction and restore the pelvic integrity with virtual fixation. The computer-assisted 3D image of the reduced acetabula was printed for surgery simulation and plate pre-bending. The postoperative CT scan was performed to compare the consistency of the preoperative planning with the surgical implants by 3D-superimposition in MIMICS14.0, and evaluated by Matta's method. Computer-based pre-operations were precisely mimicked and consistent with the actual operations in all cases. The pre-bent fixation plates had an anatomical shape specifically fit to the individual pelvis without further bending or adjustment at the time of surgery and fracture reductions were significantly improved. Seven out of 10 patients had a displacement of fracture reduction of less than 1mm; 3 cases had a displacement of fracture reduction between 1 and 2mm. The 3D printing technology combined with virtual surgery for acetabular fractures is feasible, accurate, and effective leading to improved patient-specific preoperative planning and outcome of real surgery. The results provide useful technical tips in planning pelvic surgeries. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. Impact of model-based risk analysis for liver surgery planning.

    PubMed

    Hansen, C; Zidowitz, S; Preim, B; Stavrou, G; Oldhafer, K J; Hahn, H K

    2014-05-01

    A model-based risk analysis for oncologic liver surgery was described in previous work (Preim et al. in Proceedings of international symposium on computer assisted radiology and surgery (CARS), Elsevier, Amsterdam, pp. 353–358, 2002; Hansen et al. Int I Comput Assist Radiol Surg 4(5):469–474, 2009). In this paper, we present an evaluation of this method. To prove whether and how the risk analysis facilitates the process of liver surgery planning, an explorative user study with 10 liver experts was conducted. The purpose was to compare and analyze their decision-making. The results of the study show that model-based risk analysis enhances the awareness of surgical risk in the planning stage. Participants preferred smaller resection volumes and agreed more on the safety margins’ width in case the risk analysis was available. In addition, time to complete the planning task and confidence of participants were not increased when using the risk analysis. This work shows that the applied model-based risk analysis may influence important planning decisions in liver surgery. It lays a basis for further clinical evaluations and points out important fields for future research.

  12. Three-dimensional surgical simulation.

    PubMed

    Cevidanes, Lucia H C; Tucker, Scott; Styner, Martin; Kim, Hyungmin; Chapuis, Jonas; Reyes, Mauricio; Proffit, William; Turvey, Timothy; Jaskolka, Michael

    2010-09-01

    In this article, we discuss the development of methods for computer-aided jaw surgery, which allows us to incorporate the high level of precision necessary for transferring virtual plans into the operating room. We also present a complete computer-aided surgery system developed in close collaboration with surgeons. Surgery planning and simulation include construction of 3-dimensional surface models from cone-beam computed tomography, dynamic cephalometry, semiautomatic mirroring, interactive cutting of bone, and bony segment repositioning. A virtual setup can be used to manufacture positioning splints for intraoperative guidance. The system provides further intraoperative assistance with a computer display showing jaw positions and 3-dimensional positioning guides updated in real time during the surgical procedure. The computer-aided surgery system aids in dealing with complex cases with benefits for the patient, with surgical practice, and for orthodontic finishing. Advanced software tools for diagnosis and treatment planning allow preparation of detailed operative plans, osteotomy repositioning, bone reconstructions, surgical resident training, and assessing the difficulties of the surgical procedures before the surgery. Computer-aided surgery can make the elaboration of the surgical plan a more flexible process, increase the level of detail and accuracy of the plan, yield higher operative precision and control, and enhance documentation of cases. 2010 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

  13. A novel graphical user interface for ultrasound-guided shoulder arthroscopic surgery

    NASA Astrophysics Data System (ADS)

    Tyryshkin, K.; Mousavi, P.; Beek, M.; Pichora, D.; Abolmaesumi, P.

    2007-03-01

    This paper presents a novel graphical user interface developed for a navigation system for ultrasound-guided computer-assisted shoulder arthroscopic surgery. The envisioned purpose of the interface is to assist the surgeon in determining the position and orientation of the arthroscopic camera and other surgical tools within the anatomy of the patient. The user interface features real time position tracking of the arthroscopic instruments with an optical tracking system, and visualization of their graphical representations relative to a three-dimensional shoulder surface model of the patient, created from computed tomography images. In addition, the developed graphical interface facilitates fast and user-friendly intra-operative calibration of the arthroscope and the arthroscopic burr, capture and segmentation of ultrasound images, and intra-operative registration. A pilot study simulating the computer-aided shoulder arthroscopic procedure on a shoulder phantom demonstrated the speed, efficiency and ease-of-use of the system.

  14. Computer-assisted spinal osteotomy: a technical note and report of four cases.

    PubMed

    Fujibayashi, Shunsuke; Neo, Masashi; Takemoto, Mitsuru; Ota, Masato; Nakayama, Tomitaka; Toguchida, Junya; Nakamura, Takashi

    2010-08-15

    A report of 4 cases of spinal osteotomy performed under the guidance of a computer-assisted navigation system and a technical note about the use of the navigation system for spinal osteotomy. To document the surgical technique and usefulness of computer-assisted surgery for spinal osteotomy. A computer-assisted navigation system provides accurate 3-dimensional (3D) real-time surgical information during the operation. Although there are many reports on the accuracy and usefulness of a navigation system for pedicle screw placement, there are few reports on the application for spinal osteotomy. We report on 4 complex cases including 3 solitary malignant spinal tumors and 1 spinal kyphotic deformity of ankylosing spondylitis, which were treated surgically using a computer-assisted spinal osteotomy. The surgical technique and postoperative clinical and radiologic results are presented. 3D spinal osteotomy under the guidance of a computer-assisted navigation system was performed successfully in 4 patients. All malignant tumors were resected en bloc, and the spinal deformity was corrected precisely according to the preoperative plan. Pathologic analysis confirmed the en bloc resection without tumor exposure in the 3 patients with a spinal tumor. The use of a computer-assisted navigation system will help ensure the safety and efficacy of a complex 3D spinal osteotomy.

  15. A review of robotics in surgery.

    PubMed

    Davies, B

    2000-01-01

    A brief introduction is given to the definitions and history of surgical robotics. The capabilities and merits of surgical robots are then contrasted with the related field of computer assisted surgery. A classification is then given of the various types of robot system currently being investigated internationally, together with a number of examples of different applications in both soft-tissue and orthopaedic surgery. The paper finishes with a discussion of the main difficulties facing robotic surgery and a prediction of future progress.

  16. Accuracy of virtual surgical planning of orthognathic surgery with aid of CAD/CAM fabricated surgical splint-A novel 3D analyzing algorithm.

    PubMed

    Chin, Shih-Jan; Wilde, Frank; Neuhaus, Michael; Schramm, Alexander; Gellrich, Nils-Claudius; Rana, Majeed

    2017-12-01

    The benefit of computer-assisted planning in orthognathic surgery has been extensively documented over the last decade. This study aims to evaluate the accuracy of a virtual orthognathic surgical plan by a novel three dimensional (3D) analysis method. Ten patients who required orthognathic surgery were included in this study. A virtual surgical plan was achieved by the combination of a 3D skull model acquired from computed tomography (CT) and surface scanning of the upper and lower dental arch respectively and final occlusal position. Osteotomies and movement of maxilla and mandible were simulated by Dolphin Imaging 11.8 Premium ® (Dolphin Imaging and Management Solutions, Chatsworth, CA). The surgical plan was transferred to surgical splints fabricated by means of Computer Aided Design/Computer Aided Manufacturing (CAD/CAM). Differences of three dimensional measurements between the virtual surgical plan and postoperative results were evaluated. The results from all parameters showed that the virtual surgical plans were successfully transferred by the assistance of CAD/CAM fabricated surgical splint. Wilcoxon's signed rank test showed that no statistically significant deviation between surgical plan and post-operational result could be detected. However, deviation of angle U1 axis-HP and distance of A-CP could not fulfill the clinical success criteria. Virtual surgical planning and CAD/CAM fabricated surgical splint are proven to facilitate treatment planning and offer an accurate surgical result in orthognathic surgery. Copyright © 2017 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  17. Noninvasive CT to Iso-C3D registration for improved intraoperative visualization in computer assisted orthopedic surgery

    NASA Astrophysics Data System (ADS)

    Rudolph, Tobias; Ebert, Lars; Kowal, Jens

    2006-03-01

    Supporting surgeons in performing minimally invasive surgeries can be considered as one of the major goals of computer assisted surgery. Excellent intraoperative visualization is a prerequisite to achieve this aim. The Siremobil Iso-C 3D has become a widely used imaging device, which, in combination with a navigation system, enables the surgeon to directly navigate within the acquired 3D image volume without any extra registration steps. However, the image quality is rather low compared to a CT scan and the volume size (approx. 12 cm 3) limits its application. A regularly used alternative in computer assisted orthopedic surgery is to use of a preoperatively acquired CT scan to visualize the operating field. But, the additional registration step, necessary in order to use CT stacks for navigation is quite invasive. Therefore the objective of this work is to develop a noninvasive registration technique. In this article a solution is being proposed that registers a preoperatively acquired CT scan to the intraoperatively acquired Iso-C 3D image volume, thereby registering the CT to the tracked anatomy. The procedure aligns both image volumes by maximizing the mutual information, an algorithm that has already been applied to similar registration problems and demonstrated good results. Furthermore the accuracy of such a registration method was investigated in a clinical setup, integrating a navigated Iso-C 3D in combination with an tracking system. Initial tests based on cadaveric animal bone resulted in an accuracy ranging from 0.63mm to 1.55mm mean error.

  18. Minimally invasive paediatric cardiac surgery.

    PubMed

    Bacha, Emile; Kalfa, David

    2014-01-01

    The concept of minimally invasive surgery for congenital heart disease in paediatric patients is broad, and has the aim of reducing the trauma of the operation at each stage of management. Firstly, in the operating room using minimally invasive incisions, video-assisted thoracoscopic and robotically assisted surgery, hybrid procedures, image-guided intracardiac surgery, and minimally invasive cardiopulmonary bypass strategies. Secondly, in the intensive-care unit with neuroprotection and 'fast-tracking' strategies that involve early extubation, early hospital discharge, and less exposure to transfused blood products. Thirdly, during postoperative mid-term and long-term follow-up by providing the children and their families with adequate support after hospital discharge. Improvement of these strategies relies on the development of new devices, real-time multimodality imaging, aids to instrument navigation, miniaturized and specialized instrumentation, robotic technology, and computer-assisted modelling of flow dynamics and tissue mechanics. In addition, dedicated multidisciplinary co-ordinated teams involving congenital cardiac surgeons, perfusionists, intensivists, anaesthesiologists, cardiologists, nurses, psychologists, and counsellors are needed before, during, and after surgery to go beyond apparent technological and medical limitations with the goal to 'treat more while hurting less'.

  19. Computer assisted surgery with 3D robot models and visualisation of the telesurgical action.

    PubMed

    Rovetta, A

    2000-01-01

    This paper deals with the support of virtual reality computer action in the procedures of surgical robotics. Computer support gives a direct representation of the surgical theatre. The modelization of the procedure in course and in development gives a psychological reaction towards safety and reliability. Robots similar to the ones used by the manufacturing industry can be used with little modification as very effective surgical tools. They have high precision, repeatability and are versatile in integrating with the medical instrumentation. Now integrated surgical rooms, with computer and robot-assisted intervention, are operating. The computer is the element for a decision taking aid, and the robot works as a very effective tool.

  20. Mid-term survival analysis of closed wedge high tibial osteotomy: A comparative study of computer-assisted and conventional techniques.

    PubMed

    Bae, Dae Kyung; Song, Sang Jun; Kim, Kang Il; Hur, Dong; Jeong, Ho Yeon

    2016-03-01

    The purpose of the present study was to compare the clinical and radiographic results and survival rates between computer-assisted and conventional closing wedge high tibial osteotomies (HTOs). Data from a consecutive cohort comprised of 75 computer-assisted HTOs and 75 conventional HTOs were retrospectively reviewed. The Knee Society knee and function scores, Hospital for Special Surgery (HSS) score and femorotibial angle (FTA) were compared between the two groups. Survival rates were also compared with procedure failure. The knee and function scores at one year postoperatively were slightly better in the computer-assisted group than those in conventional group (90.1 vs. 86.1) (82.0 vs. 76.0). The HSS scores at one year postoperatively were slightly better for the computer-assisted HTOs than those of conventional HTOs (89.5 vs. 81.8). The inlier of the postoperative FTA was wider in the computer-assisted group than that in the conventional HTO group (88.0% vs. 58.7%), and mean postoperative FTA was greater in the computer-assisted group that in the conventional HTO group (valgus 9.0° vs. valgus 7.6°, p<0.001). The five- and 10-year survival rates were 97.1% and 89.6%, respectively. No difference was detected in nine-year survival rates (p=0.369) between the two groups, although the clinical and radiographic results were better in the computer-assisted group that those in the conventional HTO group. Mid-term survival rates did not differ between computer-assisted and conventional HTOs. A comparative analysis of longer-term survival rate is required to demonstrate the long-term benefit of computer-assisted HTO. III. Copyright © 2015 Elsevier B.V. All rights reserved.

  1. Pedicle screw placement using image guided techniques.

    PubMed

    Merloz, P; Tonetti, J; Pittet, L; Coulomb, M; Lavalleé, S; Sautot, P

    1998-09-01

    Clinical evaluation of a computer assisted spine surgical system is presented. Eighty pedicle screws were inserted using computer assisted technology in thoracic and lumbar vertebrae for treatment of different types of disorders including fractures, spondylolisthesis, and scoliosis. Fifty-two patients with severe fractures, spondylolisthesis, or pseudoarthrosis of T10 to L5 were treated using a computer assisted technique on 1/2 the patients and performing the screw insertion manually for the other 1/2. At the same time, 28 pedicle screws were inserted in T12 to L4 vertebrae for scoliosis with the help of the computer assisted technique. Surgery was followed in all cases (66 vertebrae; 132 pedicle screws) by postoperative radiographs and computed tomographic examination, on which measurements of screw position relative to pedicle position could be done. For fractures, spondylolisthesis, or pseudarthrosis, comparison between the two groups showed that four screws in 52 (8%) vertebrae had incorrect placement with computer assisted technique whereas 22 screws in 52 (42%) vertebrae had incorrect placement with manual insertion. In patients with scoliosis, four screws in 28 (14%) vertebrae had incorrect placement. In all of the patients (132 pedicle screws) there were no neurologic complications. These results show that a computer assisted technique is much more accurate and safe than manual insertion.

  2. Gastrointestinal robot-assisted surgery. A current perspective.

    PubMed

    Lunca, Sorinel; Bouras, George; Stanescu, Alexandru Calin

    2005-12-01

    Minimally invasive techniques have revolutionized operative surgery. Computer aided surgery and robotic surgical systems strive to improve further on currently available minimally invasive surgery and open new horizons. Only several centers are currently using surgical robots and publishing data. In gastrointestinal surgery, robotic surgery is applied to a wide range of procedures, but is still in its infancy. Cholecystectomy, Nissen fundoplication and Heller myotomy are among the most frequently performed operations. The ZEUS (Computer Motion, Goleta, CA) and the da Vinci (Intuitive Surgical, Mountain View, CA) surgical systems are today the most advanced robotic systems used in gastrointestinal surgery. Most studies reported that robotic gastrointestinal surgery is feasible and safe, provides improved dexterity, better visualization, reduced fatigue and high levels of precision when compared to conventional laparoscopic surgery. Its main drawbacks are the absence of force feedback and extremely high costs. At this moment there are no reports to clearly demonstrate the superiority of robotics over conventional laparoscopic surgery. Further research and more prospective randomized trials are needed to better define the optimal application of this new technology in gastrointestinal surgery.

  3. Standardized Protocol for Virtual Surgical Plan and 3-Dimensional Surgical Template-Assisted Single-Stage Mandible Contour Surgery.

    PubMed

    Fu, Xi; Qiao, Jia; Girod, Sabine; Niu, Feng; Liu, Jian Feng; Lee, Gordon K; Gui, Lai

    2017-09-01

    Mandible contour surgery, including reduction gonioplasty and genioplasty, has become increasingly popular in East Asia. However, it is technically challenging and, hence, leads to a long learning curve and high complication rates and often needs secondary revisions. The increasing use of 3-dimensional (3D) technology makes accurate single-stage mandible contour surgery with minimum complication rates possible with a virtual surgical plan (VSP) and 3-D surgical templates. This study is to establish a standardized protocol for VSP and 3-D surgical templates-assisted mandible contour surgery and evaluate the accuracy of the protocol. In this study, we enrolled 20 patients for mandible contour surgery. Our protocol is to perform VSP based on 3-D computed tomography data. Then, design and 3-D print surgical templates based on preoperative VSP. The accuracy of the method was analyzed by 3-D comparison of VSP and postoperative results using detailed computer analysis. All patients had symmetric, natural osteotomy lines and satisfactory facial ratios in a single-stage operation. The average relative error of VSP and postoperative result on the entire skull was 0.41 ± 0.13 mm. The average new left gonial error was 0.43 ± 0.77 mm. The average new right gonial error was 0.45 ± 0.69 mm. The average pognion error was 0.79 ± 1.21 mm. Patients were very satisfied with the aesthetic results. Surgeons were very satisfied with the performance of surgical templates to facilitate the operation. Our standardized protocol of VSP and 3-D printed surgical templates-assisted single-stage mandible contour surgery results in accurate, safe, and predictable outcome in a single stage.

  4. A Bone-Thickness Map as a Guide for Bone-Anchored Port Implantation Surgery in the Temporal Bone

    PubMed Central

    Guignard, Jérémie; Arnold, Andreas; Weisstanner, Christian; Caversaccio, Marco; Stieger, Christof

    2013-01-01

    The bone-anchored port (BAP) is an investigational implant, which is intended to be fixed on the temporal bone and provide vascular access. There are a number of implants taking advantage of the stability and available room in the temporal bone. These devices range from implantable hearing aids to percutaneous ports. During temporal bone surgery, injuring critical anatomical structures must be avoided. Several methods for computer-assisted temporal bone surgery are reported, which typically add an additional procedure for the patient. We propose a surgical guide in the form of a bone-thickness map displaying anatomical landmarks that can be used for planning of the surgery, and for the intra-operative decision of the implant’s location. The retro-auricular region of the temporal and parietal bone was marked on cone-beam computed tomography scans and tridimensional surfaces displaying the bone thickness were created from this space. We compared this method using a thickness map (n = 10) with conventional surgery without assistance (n = 5) in isolated human anatomical whole head specimens. The use of the thickness map reduced the rate of Dura Mater exposition from 100% to 20% and suppressed sigmoid sinus exposures. The study shows that a bone-thickness map can be used as a low-complexity method to improve patient’s safety during BAP surgery in the temporal bone. PMID:28788390

  5. A Bone-Thickness Map as a Guide for Bone-Anchored Port Implantation Surgery in the Temporal Bone.

    PubMed

    Guignard, Jérémie; Arnold, Andreas; Weisstanner, Christian; Caversaccio, Marco; Stieger, Christof

    2013-11-19

    The bone-anchored port (BAP) is an investigational implant, which is intended to be fixed on the temporal bone and provide vascular access. There are a number of implants taking advantage of the stability and available room in the temporal bone. These devices range from implantable hearing aids to percutaneous ports. During temporal bone surgery, injuring critical anatomical structures must be avoided. Several methods for computer-assisted temporal bone surgery are reported, which typically add an additional procedure for the patient. We propose a surgical guide in the form of a bone-thickness map displaying anatomical landmarks that can be used for planning of the surgery, and for the intra-operative decision of the implant's location. The retro-auricular region of the temporal and parietal bone was marked on cone-beam computed tomography scans and tridimensional surfaces displaying the bone thickness were created from this space. We compared this method using a thickness map ( n = 10) with conventional surgery without assistance ( n = 5) in isolated human anatomical whole head specimens. The use of the thickness map reduced the rate of Dura Mater exposition from 100% to 20% and suppressed sigmoid sinus exposures. The study shows that a bone-thickness map can be used as a low-complexity method to improve patient's safety during BAP surgery in the temporal bone.

  6. Near-infrared dye marking for thoracoscopic resection of small-sized pulmonary nodules: comparison of percutaneous and bronchoscopic injection techniques.

    PubMed

    Anayama, Takashi; Hirohashi, Kentaro; Miyazaki, Ryohei; Okada, Hironobu; Kawamoto, Nobutaka; Yamamoto, Marino; Sato, Takayuki; Orihashi, Kazumasa

    2018-01-12

    Minimally invasive video-assisted thoracoscopic surgery for small-sized pulmonary nodules is challenging, and image-guided preoperative localisation is required. Near-infrared indocyanine green fluorescence is capable of deep tissue penetration and can be distinguished regardless of the background colour of the lung; thus, indocyanine green has great potential for use as a near-infrared fluorescent marker in video-assisted thoracoscopic surgery. Thirty-seven patients with small-sized pulmonary nodules, who were scheduled to undergo video-assisted thoracoscopic wedge resection, were enrolled in this study. A mixture of diluted indocyanine green and iopamidol was injected into the lung parenchyma as a marker, using either computed tomography-guided percutaneous or bronchoscopic injection techniques. Indications and limitations of the percutaneous and bronchoscopic injection techniques for marking nodules with indocyanine green fluorescence were examined and compared. In the computed tomography-guided percutaneous injection group (n = 15), indocyanine green fluorescence was detected in 15/15 (100%) patients by near-infrared thoracoscopy. A small pneumothorax occurred in 3/15 (20.0%) patients, and subsequent marking was unsuccessful after a pneumothorax occurred. In the bronchoscopic injection group (n = 22), indocyanine green fluorescence was detected in 21/22 (95.5%) patients. In 6 patients who underwent injection marking at 2 different lesion sites, 5/6 (83.3%) markers were successfully detected. Either computed tomography-guided percutaneous or bronchoscopic injection techniques can be used to mark pulmonary nodules with indocyanine green fluorescence. Indocyanine green is a safe and easily detectable fluorescent marker for video-assisted thoracoscopic surgery. Furthermore, the bronchoscopic injection approach enables surgeons to mark multiple lesion areas with less risk of causing a pneumothorax. UMIN-CTR R000027833 accepted by ICMJE. Registered 5 January 2013.

  7. A novel concept for smart trepanation.

    PubMed

    Follmann, Axel; Korff, Alexander; Fuertjes, Tobias; Kunze, Sandra C; Schmieder, Kirsten; Radermacher, Klaus

    2012-01-01

    Trepanation of the skull is a common procedure in craniofacial and neurosurgical interventions, allowing access to the innermost cranial structures. Despite a careful advancement, injury of the dura mater represents a frequent complication during these cranial openings. The technology of computer-assisted surgery offers different support systems such as navigated tools and surgical robots. This article presents a novel technical approach toward an image- and sensor-based synergistic control of the cutting depth of a manually guided soft-tissue-preserving saw. Feasibility studies in a laboratory setup modeling relevant skull tissue parameters demonstrate that errors due to computed tomography or magnetic resonance image segmentation and registration, optical tracking, and mechanical tolerances of up to 2.5 mm, imminent to many computer-assisted surgery systems, can be compensated for by the cutting tool characteristics without damaging the dura. In conclusion, the feasibility of a computer-controlled trepanation system providing a safer and efficient trepanation has been demonstrated. Injuries of the dura mater can be avoided, and the bone cutting gap can be reduced to 0.5 mm with potential benefits for the reintegration of the bone flap.

  8. Simulation training in video-assisted urologic surgery.

    PubMed

    Hoznek, András; Salomon, Laurent; de la Taille, Alexandre; Yiou, René; Vordos, Dimitrios; Larre, Stéphane; Abbou, Clément-Claude

    2006-03-01

    The current system of surgical education is facing many challenges in terms of time efficiency, costs, and patient safety. Training using simulation is an emerging area, mostly based on the experience of other high-risk professions like aviation. The goal of simulation-based training in surgery is to develop not only technical but team skills. This learning environment is stress-free and safe, allows standardization and tailoring of training, and also objectively evaluate performances. The development of simulation training is straightforward in endourology, since these procedures are video-assisted and the low degree of freedom of the instruments is easily replicated. On the other hand, these interventions necessitate a long learning curve, training in the operative room is especially costly and risky. Many models are already in use or under development in all fields of video-assisted urologic surgery: ureteroscopy, percutaneous surgery, transurethral resection of the prostate, and laparoscopy. Although bench models are essential, simulation increasingly benefits from the achievements and development of computer technology. Still in its infancy, virtual reality simulation will certainly belong to tomorrow's teaching tools.

  9. Guided Immediate Implant Placement with Wound Closure by Computer-Aided Design/Computer-Assisted Manufacture Sealing Socket Abutment: Case Report.

    PubMed

    Finelle, Gary; Lee, Sang J

    Digital technology has been widely used in the field of implant dentistry. From a surgical standpoint, computer-guided surgery can be utilized to enhance primary implant stability and to improve the precision of implant placement. From a prosthetic standpoint, computer-aided design/computer-assisted manufacture (CAD/CAM) technology has brought about various restorative options, including the fabrication of customized abutments through a virtual design based on computer-guided surgical planning. This case report describes a novel technique combining the use of a three-dimensional (3D) printed surgical template for the immediate placement of an implant, with CAD/CAM technology to optimize hard and soft tissue healing after bone grafting with the use of a socket sealing abutment.

  10. Computer-assisted surgery: virtual- and augmented-reality displays for navigation during urological interventions.

    PubMed

    van Oosterom, Matthias N; van der Poel, Henk G; Navab, Nassir; van de Velde, Cornelis J H; van Leeuwen, Fijs W B

    2018-03-01

    To provide an overview of the developments made for virtual- and augmented-reality navigation procedures in urological interventions/surgery. Navigation efforts have demonstrated potential in the field of urology by supporting guidance for various disorders. The navigation approaches differ between the individual indications, but seem interchangeable to a certain extent. An increasing number of pre- and intra-operative imaging modalities has been used to create detailed surgical roadmaps, namely: (cone-beam) computed tomography, MRI, ultrasound, and single-photon emission computed tomography. Registration of these surgical roadmaps with the real-life surgical view has occurred in different forms (e.g. electromagnetic, mechanical, vision, or near-infrared optical-based), whereby the combination of approaches was suggested to provide superior outcome. Soft-tissue deformations demand the use of confirmatory interventional (imaging) modalities. This has resulted in the introduction of new intraoperative modalities such as drop-in US, transurethral US, (drop-in) gamma probes and fluorescence cameras. These noninvasive modalities provide an alternative to invasive technologies that expose the patients to X-ray doses. Whereas some reports have indicated navigation setups provide equal or better results than conventional approaches, most trials have been performed in relatively small patient groups and clear follow-up data are missing. The reported computer-assisted surgery research concepts provide a glimpse in to the future application of navigation technologies in the field of urology.

  11. A six-degree-of-freedom passive arm with dynamic constraints (PADyC) for cardiac surgery application: preliminary experiments.

    PubMed

    Schneider, O; Troccaz, J

    2001-01-01

    The purpose of Computer-Assisted Surgery (CAS) is to help physicians and surgeons plan and execute optimal strategies from multimodal image data. The execution of such planned strategies may be assisted by guidance systems. Some of these systems, called synergistic systems, are based on the cooperation of a robotic device with a human operator. We have developed such a synergistic device: PADyC (Passive Arm with Dynamic Constraints). The basic principle of PADyC is to have a manually actuated arm that dynamically constrains the authorized motions of the surgical tool held by the human operator during a planned task. Dynamic constraints are computed from the task definition, and are implemented by a patented mechanical system. In this paper, we first introduce synergistic systems and then focus on modeling and algorithmic issues related to the dynamic constraints. Finally, we describe a 6-degree-of-freedom prototype robot designed for a clinical application (cardiac surgery) and report on preliminary experiments to date. The experimental results are then discussed, and future work is proposed. Copyright 2002 Wiley-Liss, Inc.

  12. Total knee arthroplasty with computer-assisted navigation more closely replicates normal knee biomechanics than conventional surgery.

    PubMed

    McClelland, Jodie A; Webster, Kate E; Ramteke, Alankar A; Feller, Julian A

    2017-06-01

    Computer-assisted navigation in total knee arthroplasty (TKA) reduces variability and may improve accuracy in the postoperative static alignment. The effect of navigation on alignment and biomechanics during more dynamic movements has not been investigated. This study compared knee biomechanics during level walking of 121 participants: 39 with conventional TKA, 42 with computer-assisted navigation TKA and 40 unimpaired control participants. Standing lower-limb alignment was significantly closer to ideal in participants with navigation TKA. During gait, when differences in walking speed were accounted for, participants with conventional TKA had less knee flexion during stance and swing than controls (P<0.01), but there were no differences between participants with navigation TKA and controls for the same variables. Both groups of participants with TKA had lower knee adduction moments than controls (P<0.01). In summary, there were fewer differences in the biomechanics of computer-assisted navigation TKA patients compared to controls than for patients with conventional TKA. Computer-assisted navigation TKA may restore biomechanics during walking that are closer to normal than conventional TKA. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Accuracy in planar cutting of bones: an ISO-based evaluation.

    PubMed

    Cartiaux, Olivier; Paul, Laurent; Docquier, Pierre-Louis; Francq, Bernard G; Raucent, Benoît; Dombre, Etienne; Banse, Xavier

    2009-03-01

    Computer- and robot-assisted technologies are capable of improving the accuracy of planar cutting in orthopaedic surgery. This study is a first step toward formulating and validating a new evaluation methodology for planar bone cutting, based on the standards from the International Organization for Standardization. Our experimental test bed consisted of a purely geometrical model of the cutting process around a simulated bone. Cuts were performed at three levels of surgical assistance: unassisted, computer-assisted and robot-assisted. We measured three parameters of the standard ISO1101:2004: flatness, parallelism and location of the cut plane. The location was the most relevant parameter for assessing cutting errors. The three levels of assistance were easily distinguished using the location parameter. Our ISO methodology employs the location to obtain all information about translational and rotational cutting errors. Location may be used on any osseous structure to compare the performance of existing assistance technologies.

  14. Three-Dimensional Computer-Assisted Two-Layer Elastic Models of the Face.

    PubMed

    Ueda, Koichi; Shigemura, Yuka; Otsuki, Yuki; Fuse, Asuka; Mitsuno, Daisuke

    2017-11-01

    To make three-dimensional computer-assisted elastic models for the face, we decided on five requirements: (1) an elastic texture like skin and subcutaneous tissue; (2) the ability to take pen marking for incisions; (3) the ability to be cut with a surgical knife; (4) the ability to keep stitches in place for a long time; and (5) a layered structure. After testing many elastic solvents, we have made realistic three-dimensional computer-assisted two-layer elastic models of the face and cleft lip from the computed tomographic and magnetic resonance imaging stereolithographic data. The surface layer is made of polyurethane and the inner layer is silicone. Using this elastic model, we taught residents and young doctors how to make several typical local flaps and to perform cheiloplasty. They could experience realistic simulated surgery and understand three-dimensional movement of the flaps.

  15. Cadaveric feasibility study of da Vinci Si-assisted cochlear implant with augmented visual navigation for otologic surgery.

    PubMed

    Liu, Wen P; Azizian, Mahdi; Sorger, Jonathan; Taylor, Russell H; Reilly, Brian K; Cleary, Kevin; Preciado, Diego

    2014-03-01

    To our knowledge, this is the first reported cadaveric feasibility study of a master-slave-assisted cochlear implant procedure in the otolaryngology-head and neck surgery field using the da Vinci Si system (da Vinci Surgical System; Intuitive Surgical, Inc). We describe the surgical workflow adaptations using a minimally invasive system and image guidance integrating intraoperative cone beam computed tomography through augmented reality. To test the feasibility of da Vinci Si-assisted cochlear implant surgery with augmented reality, with visualization of critical structures and facilitation with precise cochleostomy for electrode insertion. Cadaveric case study of bilateral cochlear implant approaches conducted at Intuitive Surgical Inc, Sunnyvale, California. Bilateral cadaveric mastoidectomies, posterior tympanostomies, and cochleostomies were performed using the da Vinci Si system on a single adult human donor cadaveric specimen. Radiographic confirmation of successful cochleostomies, placement of a phantom cochlear implant wire, and visual confirmation of critical anatomic structures (facial nerve, cochlea, and round window) in augmented stereoendoscopy. With a surgical mean time of 160 minutes per side, complete bilateral cochlear implant procedures were successfully performed with no violation of critical structures, notably the facial nerve, chorda tympani, sigmoid sinus, dura, or ossicles. Augmented reality image overlay of the facial nerve, round window position, and basal turn of the cochlea was precise. Postoperative cone beam computed tomography scans confirmed successful placement of the phantom implant electrode array into the basal turn of the cochlea. To our knowledge, this is the first study in the otolaryngology-head and neck surgery literature examining the use of master-slave-assisted cochleostomy with augmented reality for cochlear implants using the da Vinci Si system. The described system for cochleostomy has the potential to improve the surgeon's confidence, as well as surgical safety, efficiency, and precision by filtering tremor. The integration of augmented reality may be valuable for surgeons dealing with complex cases of congenital anatomic abnormality, for revision cochlear implant with distorted anatomy and poorly pneumatized mastoids, and as a method of interactive teaching. Further research into the cost-benefit ratio of da Vinci Si-assisted otologic surgery, as well as refinements of the proposed workflow, are required before considering clinical studies.

  16. [Application of computer-assisted 3D imaging simulation for surgery].

    PubMed

    Matsushita, S; Suzuki, N

    1994-03-01

    This article describes trends in application of various imaging technology in surgical planning, navigation, and computer aided surgery. Imaging information is essential factor for simulation in medicine. It includes three dimensional (3D) image reconstruction, neuro-surgical navigation, creating substantial model based on 3D imaging data and etc. These developments depend mostly on 3D imaging technique, which is much contributed by recent computer technology. 3D imaging can offer new intuitive information to physician and surgeon, and this method is suitable for mechanical control. By utilizing simulated results, we can obtain more precise surgical orientation, estimation, and operation. For more advancement, automatic and high speed recognition of medical imaging is being developed.

  17. Real Time Navigation-Assisted Orbital Wall Reconstruction in Blowout Fractures.

    PubMed

    Shin, Ho Seong; Kim, Se Young; Cha, Han Gyu; Han, Ba Leun; Nam, Seung Min

    2016-03-01

    Limitation in performing restoration of orbital structures is the narrow, deep, and dark surgical field, which makes it difficult to view the operative site directly. To avoid perioperative complications from this limitation, the authors have evaluated the usefulness of computer-assisted navigation techniques in surgical treatment of blowout fracture. Total 37 patients (14 medial orbital wall fractures and 23 inferior orbital wall fractures) with facial deformities had surgical treatment under the guide of navigation system between September 2012 and January 2015. All 37 patients were treated successfully and safely with navigation-assisted surgery without any complications, including diplopia, retrobulbar hematoma, globe injury, implant migration, and blindness. Blowout fracture can be treated safely under guidance of a surgical navigation system. In orbital surgery, navigation-assisted technology could give rise to improvements in the functional and aesthetic outcome and checking the position of the instruments on the surgical site in real time, without injuring important anatomic structures.

  18. Virtual university applied to telesurgery: from teleeducation to telemanipulation.

    PubMed

    Marescaux, J; Soler, L; Mutter, D; Leroy, J; Vix, M; Koehl, C; Clément, J M

    2000-01-01

    PROBLEM/BACKGROUND: In order to improve patient care by minimal invasive surgery (MIS), we perfected a Virtual TeleSurgical University that allows for teleeducation, teleconcertation, surgical planning and telemanipulation, through new Virtual Reality and multimedia systems. The organization of this innovative school was federated around three major research programs. First, the TESUS program focused on the teletransmission of medical information, allowing for videoconferencing around the world and telementoring. Next, the WeBS-Surg program is a multimedia continuous surgical education system on internet, that allows for teleeducation and teleconcertation between world experts in MIS. Then, the MASTER program (Minimal Access Surgery by Telecommunications and Robotics) allowed the development of the third millenium Operating room. It included Virtual Reality systems that delineate automatically anatomical and pathological structures of a patients from him CT-scan, and that allow for an interactive surgical planning and force-feed-back simulation. It also included a telesurgical robot named Zeus controlled by surgeons through telemanipulation system. Tests and validation shows that all these systems improved all steps of the surgical procedure: preoperatively due to a better continuous education and a computer assisted surgical planning, and peroperatively due to teleconcertation, telementoring and telemanipulation systems. Revolutionary tools for minimal invasive surgery learning, planning and performing are all ready available. These tools represents the first prototype of the computer assisted tele-robotical surgery that will be the future of surgery.

  19. Training for single port video assisted thoracoscopic surgery lung resections.

    PubMed

    McElnay, Philip J; Lim, Eric

    2015-11-01

    With many surgical training programmes providing less time for training it can be challenging for trainees to acquire the necessary surgical skills to perform complex video assisted thoracoscopic surgery (VATS) lung resections. Indeed as the utilization of single port operations increases the need to approach the operating theatre with already-existing excellent hand-eye coordination skills increases. We suggest that there are a number of ways that trainees can begin to develop these necessary skills. Firstly, using computer games that involve changing horizons and orientations. Secondly, utilizing box-trainers to practice using the thoracoscopic instruments. Thirdly, learning how essential tools such as the stapler work. Trainees will then be able to progress to meaningfully assisting in theatre and indeed learning how to perform the operation themselves. At this stage is useful to observe expert surgeons whilst they operate-to watch both their technical and non-technical skills. Ultimately, surgery is a learned skill and requires implementation of these techniques over a sustained period of time.

  20. Role of post-mapping computed tomography in virtual-assisted lung mapping.

    PubMed

    Sato, Masaaki; Nagayama, Kazuhiro; Kuwano, Hideki; Nitadori, Jun-Ichi; Anraku, Masaki; Nakajima, Jun

    2017-02-01

    Background Virtual-assisted lung mapping is a novel bronchoscopic preoperative lung marking technique in which virtual bronchoscopy is used to predict the locations of multiple dye markings. Post-mapping computed tomography is performed to confirm the locations of the actual markings. This study aimed to examine the accuracy of marking locations predicted by virtual bronchoscopy and elucidate the role of post-mapping computed tomography. Methods Automated and manual virtual bronchoscopy was used to predict marking locations. After bronchoscopic dye marking under local anesthesia, computed tomography was performed to confirm the actual marking locations before surgery. Discrepancies between marking locations predicted by the different methods and the actual markings were examined on computed tomography images. Forty-three markings in 11 patients were analyzed. Results The average difference between the predicted and actual marking locations was 30 mm. There was no significant difference between the latest version of the automated virtual bronchoscopy system (30.7 ± 17.2 mm) and manual virtual bronchoscopy (29.8 ± 19.1 mm). The difference was significantly greater in the upper vs. lower lobes (37.1 ± 20.1 vs. 23.0 ± 6.8 mm, for automated virtual bronchoscopy; p < 0.01). Despite this discrepancy, all targeted lesions were successfully resected using 3-dimensional image guidance based on post-mapping computed tomography reflecting the actual marking locations. Conclusions Markings predicted by virtual bronchoscopy were dislocated from the actual markings by an average of 3 cm. However, surgery was accurately performed using post-mapping computed tomography guidance, demonstrating the indispensable role of post-mapping computed tomography in virtual-assisted lung mapping.

  1. Treatment of Brodie's Syndrome using parasymphyseal distraction through virtual surgical planning and RP assisted customized surgical osteotomy guide-A mock surgery report

    NASA Astrophysics Data System (ADS)

    Dahake, Sandeep; Kuthe, Abhaykumar; Mawale, Mahesh

    2017-10-01

    This paper aims to describe virtual surgical planning (VSP), computer aided design (CAD) and rapid prototyping (RP) systems for the preoperative planning of accurate treatment of the Brodie's Syndrome. 3D models of the patient's maxilla and mandible were separately generated based on computed tomography (CT) image data and fabricated using RP. During the customized surgical osteotmy guide (CSOG) design process, the correct position was identified and the geometry of the CSOG was generated based on affected mandible of the patient and fabricated by a RP technique. Surgical approach such as preoperative planning and simulation of surgical procedures was performed using advanced software. The VSP and RP assisted CSOG was used to avoid the damage of the adjacent teeth and neighboring healthy tissues. Finally the mock surgery was performed on the biomodel (i.e. diseased RP model) of mandible with reference to the normal maxilla using osteotomy bur with the help of CSOG. Using this CSOG the exact osteotomy of the mandible and the accurate placement of the distractor were obtained. It ultimately improved the accuracy of the surgery in context of the osteotomy and distraction. The time required in cutting the mandible and placement of the distractor was found comparatively less than the regular free hand surgery.

  2. Comparison of computer assisted surgery with conventional technique for treatment of abaxial distal phalanx fractures in horses: an in vitro study.

    PubMed

    Rossol, Melanie; Gygax, Diego; Andritzky-Waas, Juliane; Zheng, Guoyan; Lischer, Christoph J; Zhang, Xuan; Auer, Joerg A

    2008-01-01

    To (1) evaluate and compare computer-assisted surgery (CAS) with conventional screw insertion (conventional osteosynthesis [COS]) for treatment of equine abaxial distal phalanx fractures; (2) compare planned screw position with actual postoperative position; and (3) determine preferred screw insertion direction. Experimental study. Cadaveric equine limbs (n=32). In 8 specimens each, a 4.5 mm cortex bone screw was inserted in lag fashion in dorsopalmar (plantar) direction using CAS or COS. In 2 other groups of 8, the screws were inserted in opposite direction. Precision of CAS was determined by comparison of planned and actual screw position. Preferred screw direction was also assessed for CAS and COS. In 4 of 6 direct comparisons, screw positioning was significantly better with CAS. Results of precision analysis for screw position were similar to studies published in human medicine. None of evaluated criteria identified a preferred direction for screw insertion. For abaxial fractures of the distal phalanx, superior precision in screw position is achieved with CAS technique compared with COS technique. Abaxial fractures of the distal phalanx lend themselves to computer-assisted implantation of 1 screw in a dorsopalmar (plantar) direction. Because of the complex anatomic relationships, and our results, we discourage use of COS technique for repair of this fracture type.

  3. Management of an ingested fish bone in the lung using video-assist thoracic surgery: a case report.

    PubMed

    Tan, Sichuang; Tan, Sipin; Peng, Muyun; Yu, Fenglei

    2015-06-01

    We report a case of lung abscess caused by an ingested fish bone that was successfully treated by minimally invasive surgery. Although cases of ingested foreign body abscess are well reported, lung abscess caused by ingested fish bone is extremely rare. To date, less than 10 similar cases have been reported in the literature. To the best of our knowledge, the case presented in this case report is the first report of this kind that was successfully treated by video-assist thoracic surgery (VATS). A 47-year-old man was admitted to department of thoracic surgery with the complaint of continues dry cough and fever. The patient accidentally swallowed a long sharp-blade-shaped fish bone 20 days before, which perforated the upper thoracic esophagus on the right and embedded in the right upper lobe.The diagnosis was verified by computed tomography scan and a video-assist thoracic surgery procedure was successfully performed to treat the patient. The patient survived the esophageal perforation fortunately without involvement of great vessel injury and probable mediastinitis. This report may provide additional experience on lung abscess caused by ingested fish bones. However, it is also important to educate the public of the risks of trying to force an ingested object down into the stomach.

  4. Computer-assisted surgery of the paranasal sinuses: technical and clinical experience with 368 patients, using the Vector Vision Compact system.

    PubMed

    Stelter, K; Andratschke, M; Leunig, A; Hagedorn, H

    2006-12-01

    This paper presents our experience with a navigation system for functional endoscopic sinus surgery. In this study, we took particular note of the surgical indications and risks and the measurement precision and preparation time required, and we present one brief case report as an example. Between 2000 and 2004, we performed functional endoscopic sinus surgery on 368 patients at the Ludwig Maximilians University, Munich, Germany. We used the Vector Vision Compact system (BrainLAB) with laser registration. The indications for surgery ranged from severe nasal polyps and chronic sinusitis to malignant tumours of the paranasal sinuses and skull base. The time needed for data preparation was less than five minutes. The time required for preparation and patient registration depended on the method used and the experience of the user. In the later cases, it took 11 minutes on average, using Z-Touch registration. The clinical plausibility test produced an average deviation of 1.3 mm. The complications of system use comprised one intra-operative re-registration (18 per cent) and one complete failure (5 per cent). Despite the assistance of an accurate working computer, the anterior ethmoidal artery was incised in one case. However, in all 368 cases, we experienced no cerebrospinal fluid leaks, optic nerve lesions, retrobulbar haematomas or intracerebral bleeding. There were no deaths. From our experience with computer-guided surgical procedures, we conclude that computer-guided navigational systems are so accurate that the risk of misleading the surgeon is minimal. In the future, their use in certain specialized procedures will be not only sensible but mandatory. We recommend their use not only in difficult surgical situations but also in routine procedures and for surgical training.

  5. 3D Surgical Simulation

    PubMed Central

    Cevidanes, Lucia; Tucker, Scott; Styner, Martin; Kim, Hyungmin; Chapuis, Jonas; Reyes, Mauricio; Proffit, William; Turvey, Timothy; Jaskolka, Michael

    2009-01-01

    This paper discusses the development of methods for computer-aided jaw surgery. Computer-aided jaw surgery allows us to incorporate the high level of precision necessary for transferring virtual plans into the operating room. We also present a complete computer-aided surgery (CAS) system developed in close collaboration with surgeons. Surgery planning and simulation include construction of 3D surface models from Cone-beam CT (CBCT), dynamic cephalometry, semi-automatic mirroring, interactive cutting of bone and bony segment repositioning. A virtual setup can be used to manufacture positioning splints for intra-operative guidance. The system provides further intra-operative assistance with the help of a computer display showing jaw positions and 3D positioning guides updated in real-time during the surgical procedure. The CAS system aids in dealing with complex cases with benefits for the patient, with surgical practice, and for orthodontic finishing. Advanced software tools for diagnosis and treatment planning allow preparation of detailed operative plans, osteotomy repositioning, bone reconstructions, surgical resident training and assessing the difficulties of the surgical procedures prior to the surgery. CAS has the potential to make the elaboration of the surgical plan a more flexible process, increase the level of detail and accuracy of the plan, yield higher operative precision and control, and enhance documentation of cases. Supported by NIDCR DE017727, and DE018962 PMID:20816308

  6. Three-Dimensional Liver Surgery Simulation: Computer-Assisted Surgical Planning with Three-Dimensional Simulation Software and Three-Dimensional Printing.

    PubMed

    Oshiro, Yukio; Ohkohchi, Nobuhiro

    2017-06-01

    To perform accurate hepatectomy without injury, it is necessary to understand the anatomical relationship among the branches of Glisson's sheath, hepatic veins, and tumor. In Japan, three-dimensional (3D) preoperative simulation for liver surgery is becoming increasingly common, and liver 3D modeling and 3D hepatectomy simulation by 3D analysis software for liver surgery have been covered by universal healthcare insurance since 2012. Herein, we review the history of virtual hepatectomy using computer-assisted surgery (CAS) and our research to date, and we discuss the future prospects of CAS. We have used the SYNAPSE VINCENT medical imaging system (Fujifilm Medical, Tokyo, Japan) for 3D visualization and virtual resection of the liver since 2010. We developed a novel fusion imaging technique combining 3D computed tomography (CT) with magnetic resonance imaging (MRI). The fusion image enables us to easily visualize anatomic relationships among the hepatic arteries, portal veins, bile duct, and tumor in the hepatic hilum. In 2013, we developed an original software, called Liversim, which enables real-time deformation of the liver using physical simulation, and a randomized control trial has recently been conducted to evaluate the use of Liversim and SYNAPSE VINCENT for preoperative simulation and planning. Furthermore, we developed a novel hollow 3D-printed liver model whose surface is covered with frames. This model is useful for safe liver resection, has better visibility, and the production cost is reduced to one-third of a previous model. Preoperative simulation and navigation with CAS in liver resection are expected to help planning and conducting a surgery and surgical education. Thus, a novel CAS system will contribute to not only the performance of reliable hepatectomy but also to surgical education.

  7. [Guided maxillofacial surgery: Simulation and surgery aided by stereolithographic guides and custom-made miniplates.

    PubMed

    Philippe, B

    2013-08-05

    We present a new model of guided surgery, exclusively using computer assistance, from the preoperative planning of osteotomies to the actual surgery with the aid of stereolithographic cutting guides and osteosynthetic miniplates designed and made preoperatively, using custom-made titanium miniplates thanks to direct metal laser sintering. We describe the principles that guide the designing and industrial manufacturing of this new type of osteosynthesis miniplates. The surgical procedure is described step-by-step using several representative cases of dento-maxillofacial dysmorphosis. The encouraging short-term results demonstrate the wide range of application of this new technology for cranio-maxillofacial surgery, whatever the type of osteotomy performed, and for plastic reconstructive surgery. Copyright © 2013. Published by Elsevier Masson SAS.

  8. A novel cost-effective computer-assisted imaging technology for accurate placement of thoracic pedicle screws.

    PubMed

    Abe, Yuichiro; Ito, Manabu; Abumi, Kuniyoshi; Kotani, Yoshihisa; Sudo, Hideki; Minami, Akio

    2011-11-01

    Use of computer-assisted spine surgery (CASS) technologies, such as navigation systems, to improve the accuracy of pedicle screw (PS) placement is increasingly popular. Despite of their benefits, previous CASS systems are too expensive to be ubiquitously employed, and more affordable and portable systems are desirable. The aim of this study was to introduce a novel and affordable computer-assisted technique that 3-dimensionally visualizes anatomical features of the pedicles and assists in PS insertion. The authors have termed this the 3D-visual guidance technique for inserting pedicle screws (3D-VG TIPS). The 3D-VG technique for placing PSs requires only a consumer-class computer with an inexpensive 3D DICOM viewer; other special equipment is unnecessary. Preoperative CT data of the spine were collected for each patient using the 3D-VG TIPS. In this technique, the anatomical axis of each pedicle can be analyzed by volume-rendered 3D models, as with existing navigation systems, and both the ideal entry point and the trajectory of each PS can be visualized on the surface of 3D-rendered images. Intraoperative guidance slides are made from these images and displayed on a TV monitor in the operating room. The surgeon can insert PSs according to these guidance slides. The authors enrolled 30 patients with adolescent idiopathic scoliosis (AIS) who underwent posterior fusion with segmental screw fixation for validation of this technique. The novel technique allowed surgeons, from office or home, to evaluate the precise anatomy of each pedicle and the risks of screw misplacement, and to perform 3D preoperative planning for screw placement on their own computer. Looking at both 3D guidance images on a TV monitor and the bony structures of the posterior elements in each patient in the operating theater, surgeons were able to determine the best entry point for each PS with ease and confidence. Using the current technique, the screw malposition rate was 4.5% in the thoracic region in corrective surgery for AIS. The authors found that 3D-VG TIPS worked on a consumer-class computer and easily visualized the ideal entry point and trajectory of PSs in any operating theater without costly special equipment. This new technique is suitable for preoperative planning and intraoperative guidance when performing reconstructive surgery with PSs.

  9. Improved depth perception with three-dimensional auxiliary display and computer generated three-dimensional panoramic overviews in robot-assisted laparoscopy

    PubMed Central

    Wieringa, Fokko P.; Bouma, Henri; Eendebak, Pieter T.; van Basten, Jean-Paul A.; Beerlage, Harrie P.; Smits, Geert A. H. J.; Bos, Jelte E.

    2014-01-01

    Abstract. In comparison to open surgery, endoscopic surgery offers impaired depth perception and narrower field-of-view. To improve depth perception, the Da Vinci robot offers three-dimensional (3-D) video on the console for the surgeon but not for assistants, although both must collaborate. We improved the shared perception of the whole surgical team by connecting live 3-D monitors to all three available Da Vinci generations, probed user experience after two years by questionnaire, and compared time measurements of a predefined complex interaction task performed with a 3-D monitor versus two-dimensional. Additionally, we investigated whether the complex mental task of reconstructing a 3-D overview from an endoscopic video can be performed by a computer and shared among users. During the study, 925 robot-assisted laparoscopic procedures were performed in three hospitals, including prostatectomies, cystectomies, and nephrectomies. Thirty-one users participated in our questionnaire. Eighty-four percent preferred 3-D monitors and 100% reported spatial-perception improvement. All participating urologists indicated quicker performance of tasks requiring delicate collaboration (e.g., clip placement) when assistants used 3-D monitors. Eighteen users participated in a timing experiment during a delicate cooperation task in vitro. Teamwork was significantly (40%) faster with the 3-D monitor. Computer-generated 3-D reconstructions from recordings offered very wide interactive panoramas with educational value, although the present embodiment is vulnerable to movement artifacts. PMID:26158026

  10. Evolution-Based Methods for Selecting Point Data for Object Localization: Applications to Computer-Assisted Surgery.

    DTIC Science & Technology

    1996-11-01

    being evaluated in cadaver trials. Shumeet Baluja was supported by a National Science Foundation Graduate Student Fellowship and a Graduate Student...partially supported by a National Science Foundation National Challenge grant (award IRI-9422734).

  11. Cerebral Fat Embolism After Video-Assisted Thoracic Surgery.

    PubMed

    Scarpino, Maenia; Lanzo, Giovanni; Cappelli, Francesco; Moretti, Marco; Misuri, Gianni; Voltolini, Luca; Pistolesi, Massimo; Amantini, Aldo; Grippo, Antonello

    2016-11-01

    Cerebral fat embolism (CFE) is an uncommon disease occurring mainly after traumatic lower limb long bone fractures. A 64-year-old woman with pneumonia and bilateral pleural effusion underwent video-assisted thoracic surgery (VATS). After 3 days, the patient had an acute decrease in consciousness level followed by the onset of seizures and right hemiparesis. Brain computed tomography and magnetic resonance imaging showed findings suggestive of CFE. CFE occurring after an uncommon nontraumatic cause of fat embolism, such as VATS, is a rare clinical event whose diagnosis could be challenging. Neuroimaging can hasten diagnosis and prevent other unnecessary investigations and treatments. Copyright © 2016 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  12. A Third Arm for the Surgeon

    NASA Technical Reports Server (NTRS)

    1994-01-01

    In laparoscopic surgery, tiny incisions are made in the patient's body and a laparoscope (an optical tube with a camera at the end) is inserted. The camera's image is projected onto two video screens, whose views guide the surgeon through the procedure. AESOP, a medical robot developed by Computer Motion, Inc. with NASA assistance, eliminates the need for a human assistant to operate the camera. The surgeon uses a foot pedal control to move the device, allowing him to use both hands during the surgery. Miscommunication is avoided; AESOP's movement is smooth and steady, and the memory vision is invaluable. Operations can be completed more quickly, and the patient spends less time under anesthesia. AESOP has been approved by the FDA.

  13. Iterations of computer- and template assisted mandibular or maxillary reconstruction with free flaps containing the lateral scapular border--Evolution of a biplanar plug-on cutting guide.

    PubMed

    Cornelius, Carl-Peter; Giessler, Goetz Andreas; Wilde, Frank; Metzger, Marc Christian; Mast, Gerson; Probst, Florian Andreas

    2016-03-01

    Computer-assisted planning and intraoperative implementation using templates have become appreciated modalities in craniofacial reconstruction with fibula and DCIA flaps due to saving in operation time, improved accuracy of osteotomies and easy insetting. Up to now, a similar development for flaps from the subscapular vascular system, namely the lateral scapular border and tip, has not been addressed in the literature. A cohort of 12 patients who underwent mandibular (n = 10) or maxillary (n = 2) reconstruction with free flaps containing the lateral scapular border and tip using computer-assisted planning, stereolithography (STL) models and selective laser sintered (SLS) templates for bone contouring and sub-segmentation osteotomies was reviewed focussing on iterations in the design of computer generated tools and templates. The technical evolution migrated from hybrid STL models over SLS templates for cut out as well as sub-segmentation with a uniplanar framework to plug-on tandem template assemblies providing a biplanar access for the in toto cut out from the posterior aspect in succession with contouring into sub-segments from the medial side. The latest design version is the proof of concept that virtual planning of bone flaps from the lateral scapular border can be successfully transferred into surgery by appropriate templates. Copyright © 2015 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  14. [Application of 3D printing and computer-assisted surgical simulation in preoperative planning for acetabular fracture].

    PubMed

    Liu, Xin; Zeng, Can-Jun; Lu, Jian-Sen; Lin, Xu-Chen; Huang, Hua-Jun; Tan, Xin-Yu; Cai, Dao-Zhang

    2017-03-20

    To evaluate the feasibility and effectiveness of using 3D printing and computer-assisted surgical simulation in preoperative planning for acetabular fractures. A retrospective analysis was performed in 53 patients with pelvic fracture, who underwent surgical treatment between September, 2013 and December, 2015 with complete follow-up data. Among them, 19 patients were treated with CT three-dimensional reconstruction, computer-assisted virtual reset internal fixation, 3D model printing, and personalized surgery simulation before surgery (3D group), and 34 patients underwent routine preoperative examination (conventional group). The intraoperative blood loss, transfusion volume, times of intraoperative X-ray, operation time, Matta score and Merle D' Aubigne & Postel score were recorded in the 2 groups. Preoperative planning and postoperative outcomes in the two groups were compared. All the operations were completed successfully. In 3D group, significantly less intraoperative blood loss, transfusion volume, fewer times of X-ray, and shortened operation time were recorded compared with those in the conventional group (P<0.05). According to the Matta scores, excellent or good fracture reduction was achieved in 94.7% (18/19) of the patients in 3D group and in 82.4% (28/34) of the patients in conventional group; the rates of excellent and good hip function at the final follow-up were 89.5% (17/19) in the 3D group and 85.3% (29/34) in the conventional group (P>0.05). In the 3D group, the actual internal fixation well matched the preoperative design. 3D printing and computer-assisted surgical simulation for preoperative planning is feasible and accurate for management of acetabular fracture and can effectively improve the operation efficiency.

  15. [A new concept in digestive surgery: the computer assisted surgical procedure, from virtual reality to telemanipulation].

    PubMed

    Marescaux, J; Clément, J M; Nord, M; Russier, Y; Tassetti, V; Mutter, D; Cotin, S; Ayache, N

    1997-11-01

    Surgical simulation increasingly appears to be an essential aspect of tomorrow's surgery. The development of a hepatic surgery simulator is an advanced concept calling for a new writing system which will transform the medical world: virtual reality. Virtual reality extends the perception of our five senses by representing more than the real state of things by the means of computer sciences and robotics. It consists of three concepts: immersion, navigation and interaction. Three reasons have led us to develop this simulator: the first is to provide the surgeon with a comprehensive visualisation of the organ. The second reason is to allow for planning and surgical simulation that could be compared with the detailed flight-plan for a commercial jet pilot. The third lies in the fact that virtual reality is an integrated part of the concept of computer assisted surgical procedure. The project consists of a sophisticated simulator which has to include five requirements: visual fidelity, interactivity, physical properties, physiological properties, sensory input and output. In this report we will describe how to get a realistic 3D model of the liver from bi-dimensional 2D medical images for anatomical and surgical training. The introduction of a tumor and the consequent planning and virtual resection is also described, as are force feedback and real-time interaction.

  16. Clinical and radiological outcomes of transoral endoscope-assisted treatment of mandibular condylar fractures.

    PubMed

    You, H-J; Moon, K-C; Yoon, E-S; Lee, B-I; Park, S-H

    2016-03-01

    Fractures of the mandibular condyle are one of the most common craniofacial fractures. However, the diagnosis and treatment of these fractures is controversial because of the multiple surgical approaches available. The purposes of this study were to identify surgery-related technical tips for better outcomes and to evaluate the results as well as complications encountered during 7 years of endoscope use to supplement the limited intraoral approach in the treatment of mandibular condylar fractures. Between 2005 and 2012, 50 patients with condylar fractures underwent endoscope-assisted reduction surgery. Postoperative facial bone computed tomography and panoramic radiography demonstrated adequate reduction of the condylar fractures in all patients. No condylar resorption was detected, and most patients displayed a satisfactory functional and structural recovery. There was no facial nerve damage or transitory hypoesthesia, and there were no visible scars after the surgery. Transoral endoscope-assisted treatment is a challenging but reliable method with lower morbidity and a rapid recovery. Copyright © 2015 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  17. Applications of Computer-Assisted Navigation for the Minimally Invasive Reduction of Isolated Zygomatic Arch Fractures.

    PubMed

    Li, Zhi; Yang, Rong-Tao; Li, Zu-Bing

    2015-09-01

    Computer-assisted navigation has been widely used in oral and maxillofacial surgery. The purpose of this study was to describe the applications of computer-assisted navigation for the minimally invasive reduction of isolated zygomatic arch fractures. All patients identified as having isolated zygomatic arch fractures presenting to the authors' department from April 2013 through November 2014 were included in this prospective study. Minimally invasive reductions of isolated zygomatic arch fractures were performed on these patients under the guidance of computer-assisted navigation. The reduction status was evaluated by postoperative computed tomography (CT) 1 week after the operation. Postoperative complications and facial contours were evaluated during follow-up. Functional recovery was evaluated by the difference between the preoperative maximum interincisal mouth opening and that at the final follow-up. Twenty-three patients were included in this case series. The operation proceeded well in all patients. Postoperatively, all patients displayed uneventful healing without postoperative complication. Postoperative CT showed exact reduction in all cases. Satisfactory facial contour and functional recovery were observed in all patients. The preoperative maximal mouth opening ranged from 8 to 25 mm, and the maximal mouth opening at the final follow-up ranged from 36 to 42 mm. Computer-assisted navigation can be used not only for guiding zygomatic arch fracture reduction, but also for assessing reduction. Computer-assisted navigation is an effective and minimally invasive technique that can be applied in the reduction of isolated zygomatic arch fractures. Copyright © 2015 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  18. SAGES TAVAC safety and effectiveness analysis: da Vinci ® Surgical System (Intuitive Surgical, Sunnyvale, CA).

    PubMed

    Tsuda, Shawn; Oleynikov, Dmitry; Gould, Jon; Azagury, Dan; Sandler, Bryan; Hutter, Matthew; Ross, Sharona; Haas, Eric; Brody, Fred; Satava, Richard

    2015-10-01

    The da Vinci(®) Surgical System (Intuitive Surgical, Sunnyvale, CA, USA) is a computer-assisted (robotic) surgical system designed to enable and enhance minimally invasive surgery. The Food and Drug Administration (FDA) has cleared computer-assisted surgical systems for use by trained physicians in an operating room environment for laparoscopic surgical procedures in general, cardiac, colorectal, gynecologic, head and neck, thoracic and urologic surgical procedures. There are substantial numbers of peer-reviewed papers regarding the da Vinci(®) Surgical System, and a thoughtful assessment of evidence framed by clinical opinion is warranted. The SAGES da Vinci(®) TAVAC sub-committee performed a literature review of the da Vinci(®) Surgical System regarding gastrointestinal surgery. Conclusions by the sub-committee were vetted by the SAGES TAVAC Committee and SAGES Executive Board. Following revisions, the document was evaluated by the TAVAC Committee and Executive Board again for final approval. Several conclusions were drawn based on expert opinion organized by safety, efficacy, and cost for robotic foregut, bariatric, hepatobiliary/pancreatic, colorectal surgery, and single-incision cholecystectomy. Gastrointestinal surgery with the da Vinci(®) Surgical System is safe and comparable, but not superior to standard laparoscopic approaches. Although clinically acceptable, its use may be costly for select gastrointestinal procedures. Current data are limited to the da Vinci(®) Surgical System; further analyses are needed.

  19. Plastic Surgery Applications Using Three-Dimensional Planning and Computer-Assisted Design and Manufacturing.

    PubMed

    Pfaff, Miles J; Steinbacher, Derek M

    2016-03-01

    Three-dimensional analysis and planning is a powerful tool in plastic and reconstructive surgery, enabling improved diagnosis, patient education and communication, and intraoperative transfer to achieve the best possible results. Three-dimensional planning can increase efficiency and accuracy, and entails five core components: (1) analysis, (2) planning, (3) virtual surgery, (4) three-dimensional printing, and (5) comparison of planned to actual results. The purpose of this article is to provide an overview of three-dimensional virtual planning and to provide a framework for applying these systems to clinical practice. Therapeutic, V.

  20. [Computer-assisted operational planning for pediatric abdominal surgery. 3D-visualized MRI with volume rendering].

    PubMed

    Günther, P; Tröger, J; Holland-Cunz, S; Waag, K L; Schenk, J P

    2006-08-01

    Exact surgical planning is necessary for complex operations of pathological changes in anatomical structures of the pediatric abdomen. 3D visualization and computer-assisted operational planning based on CT data are being increasingly used for difficult operations in adults. To minimize radiation exposure and for better soft tissue contrast, sonography and MRI are the preferred diagnostic methods in pediatric patients. Because of manifold difficulties 3D visualization of these MRI data has not been realized so far, even though the field of embryonal malformations and tumors could benefit from this.A newly developed and modified raycasting-based powerful 3D volume rendering software (VG Studio Max 1.2) for the planning of pediatric abdominal surgery is presented. With the help of specifically developed algorithms, a useful surgical planning system is demonstrated. Thanks to the easy handling and high-quality visualization with enormous gain of information, the presented system is now an established part of routine surgical planning.

  1. Tissue classification for laparoscopic image understanding based on multispectral texture analysis

    NASA Astrophysics Data System (ADS)

    Zhang, Yan; Wirkert, Sebastian J.; Iszatt, Justin; Kenngott, Hannes; Wagner, Martin; Mayer, Benjamin; Stock, Christian; Clancy, Neil T.; Elson, Daniel S.; Maier-Hein, Lena

    2016-03-01

    Intra-operative tissue classification is one of the prerequisites for providing context-aware visualization in computer-assisted minimally invasive surgeries. As many anatomical structures are difficult to differentiate in conventional RGB medical images, we propose a classification method based on multispectral image patches. In a comprehensive ex vivo study we show (1) that multispectral imaging data is superior to RGB data for organ tissue classification when used in conjunction with widely applied feature descriptors and (2) that combining the tissue texture with the reflectance spectrum improves the classification performance. Multispectral tissue analysis could thus evolve as a key enabling technique in computer-assisted laparoscopy.

  2. Prospective Clinical Trial of Robotically Assisted Endoscopic Coronary Grafting With 1-Year Follow-Up

    PubMed Central

    Prasad, Sunil M.; Ducko, Christopher T.; Stephenson, Edward R.; Chambers, Charles E.; Damiano, Ralph J.

    2001-01-01

    Objective To follow up in prospective fashion patients with coronary artery anastomoses completed endoscopically with robotic assistance. The robotic system was evaluated for safety and its effectiveness in completing microsurgical coronary anastomoses. Summary Background Data Recently there has been an interest in using robotics and computers to enhance the surgeon’s ability to perform endoscopic cardiac surgery. This interest has stemmed from the rapid advancement of technology and the desire to make cardiac surgery less invasive. Using traditional endoscopic instruments, it has not been possible to perform coronary surgery. Methods Nineteen patients underwent robotically assisted endoscopic coronary artery bypass grafting of the left internal thoracic artery (LITA) to the left anterior descending artery (LAD). Two robotic instruments and one endoscopic camera were placed through three 5-mm ports. A robotic system was used to construct the LITA–LAD anastomosis. All other required grafts were completed by conventional techniques. Results Seventeen LITA–LAD grafts (89%) had adequate intraoperative flow. The mean LITA–LAD graft flow was 38.5 ± 5 mL/min. At 8 weeks, LITA–LAD grafts were assessed by angiography and showed 100% patency with thrombolysis in myocardial infarction (TIMI) I flow. At a mean follow-up of 17 ± 4.2 months, all patients were NYHA class I and there were no adverse cardiac events. Conclusions The results from the first prospective clinical trial of robotically assisted endoscopic coronary bypass surgery in the United States showed favorable short-term outcomes with no adverse events. Robotic assistance is an enabling technology allowing the performance of endoscopic coronary anastomoses. PMID:11371730

  3. [Using the CAS (computer-assisted surgery) system in arthroscopic cruciate ligament surgery--adaptation and application in clinical practice].

    PubMed

    Bernsmann, K; Rosenthal, A; Sati, M; Ansari, B; Wiese, M

    2001-01-01

    The anterior cruciate ligament (ACL) is of great importance for the knee joint function. In the case of a complete ligament injury there is hardly any chance for complete recovery. The clear advantages of an operative reconstruction by replacing the ACL has been shown in many trails. The accurate placement of the graft's insertions has a significant effect on the mid- and probably long-term outcome of this procedure. Reviewing the literature, there are poor long-term results of ACL replacement in 5 to 52% of all cases, depending on the score system. One of the main reasons for unacceptable results is graft misplacement. This led to the construction of a CAS system for ACL replacement. The system assists this surgical procedure by navigating the exact position of the drilling holes. The Potential deformation quantity of the transplant can be controlled by this system in real time. 40 computer-assisted ACL replacements have been performed under active use of the CAS system. The short-term results are encouraging, no special complications have been seen so far. Prospective long-term follow-up studies are ongoing. ACL reconstruction by manual devices has many sources of error. The CAS system is able to give the surgeon reasonable views that are unachieveable by conventional surgery. He is therefore able to control a source of error and to optimise the results. The feasibility of this device in clinical routine use has been proven.

  4. Linear Optimization and Image Reconstruction

    DTIC Science & Technology

    1994-06-01

    final example is again a novel one. We formulate the problem of computer assisted tomographic ( CAT ) image reconstruction as a linear optimization...possibility that a patient, Fred, suffers from a brain tumor. Further, the physician opts to make use of the CAT (Computer Aided Tomography) scan device...and examine the inside of Fred’s head without exploratory surgery. The CAT scan machine works by projecting a finite number of X-rays of known

  5. Atrioesophageal Fistula after Minimally Invasive Video-Assisted Epicardial Ablation for Lone Atrial Fibrillation.

    PubMed

    Kik, Charles; van Valen, Richard; Mokhles, Mostafa M; Bekkers, Jos A; Bogers, Ad J J C

    2017-09-01

    Minimally invasive video-assisted epicardial beating heart ablation for lone atrial fibrillation claims to be safe and effective. We, however, report on three patients with an atrioesophageal fistula after this procedure. The exact pathogenesis of this complication is unknown. All patients presented around 6 weeks after surgery with either fever or neurological deficits. Diagnosis can be made by computed tomography scan. We advocate an aggressive surgical approach with closure of the atrial defect on cardiopulmonary bypass and closure and reinforcement of the esophagus with an intercostal muscle flap in a single-stage surgery. Some caution as to the low-risk character of this procedure seems to be realistic. Georg Thieme Verlag KG Stuttgart · New York.

  6. Augmented Reality Based Navigation for Computer Assisted Hip Resurfacing: A Proof of Concept Study.

    PubMed

    Liu, He; Auvinet, Edouard; Giles, Joshua; Rodriguez Y Baena, Ferdinando

    2018-05-23

    Implantation accuracy has a great impact on the outcomes of hip resurfacing such as recovery of hip function. Computer assisted orthopedic surgery has demonstrated clear advantages for the patients, with improved placement accuracy and fewer outliers, but the intrusiveness, cost, and added complexity have limited its widespread adoption. To provide seamless computer assistance with improved immersion and a more natural surgical workflow, we propose an augmented-reality (AR) based navigation system for hip resurfacing. The operative femur is registered by processing depth information from the surgical site with a commercial depth camera. By coupling depth data with robotic assistance, obstacles that may obstruct the femur can be tracked and avoided automatically to reduce the chance of disruption to the surgical workflow. Using the registration result and the pre-operative plan, intra-operative surgical guidance is provided through a commercial AR headset so that the user can perform the operation without additional physical guides. To assess the accuracy of the navigation system, experiments of guide hole drilling were performed on femur phantoms. The position and orientation of the drilled holes were compared with the pre-operative plan, and the mean errors were found to be approximately 2 mm and 2°, results which are in line with commercial computer assisted orthopedic systems today.

  7. Real-time 3D image reconstruction guidance in liver resection surgery.

    PubMed

    Soler, Luc; Nicolau, Stephane; Pessaux, Patrick; Mutter, Didier; Marescaux, Jacques

    2014-04-01

    Minimally invasive surgery represents one of the main evolutions of surgical techniques. However, minimally invasive surgery adds difficulty that can be reduced through computer technology. From a patient's medical image [US, computed tomography (CT) or MRI], we have developed an Augmented Reality (AR) system that increases the surgeon's intraoperative vision by providing a virtual transparency of the patient. AR is based on two major processes: 3D modeling and visualization of anatomical or pathological structures appearing in the medical image, and the registration of this visualization onto the real patient. We have thus developed a new online service, named Visible Patient, providing efficient 3D modeling of patients. We have then developed several 3D visualization and surgical planning software tools to combine direct volume rendering and surface rendering. Finally, we have developed two registration techniques, one interactive and one automatic providing intraoperative augmented reality view. From January 2009 to June 2013, 769 clinical cases have been modeled by the Visible Patient service. Moreover, three clinical validations have been realized demonstrating the accuracy of 3D models and their great benefit, potentially increasing surgical eligibility in liver surgery (20% of cases). From these 3D models, more than 50 interactive AR-assisted surgical procedures have been realized illustrating the potential clinical benefit of such assistance to gain safety, but also current limits that automatic augmented reality will overcome. Virtual patient modeling should be mandatory for certain interventions that have now to be defined, such as liver surgery. Augmented reality is clearly the next step of the new surgical instrumentation but remains currently limited due to the complexity of organ deformations during surgery. Intraoperative medical imaging used in new generation of automated augmented reality should solve this issue thanks to the development of Hybrid OR.

  8. Hybrid tracking and control system for computer-aided retinal surgery

    NASA Astrophysics Data System (ADS)

    Ferguson, R. D.; Wright, Cameron H. G.; Rylander, Henry G., III; Welch, Ashley J.; Barrett, Steven F.

    1996-05-01

    We describe initial experimental results of a new hybrid digital and analog design for retinal tracking and laser beam control. Initial results demonstrate tracking rates which exceed the equivalent of 50 degrees per second in the eye, with automatic lesion pattern creation and robust loss of lock detection. Robotically assisted laser surgery to treat conditions such as diabetic retinopathy, macular degeneration, and retinal tears can now be realized under clinical conditions with requisite safety using standard video hardware and inexpensive optical components.

  9. [Robotics in general surgery: personal experience, critical analysis and prospectives].

    PubMed

    Fracastoro, Gerolamo; Borzellino, Giuseppe; Castelli, Annalisa; Fiorini, Paolo

    2005-01-01

    Today mini invasive surgery has the chance to be enhanced with sophisticated informative systems (Computer Assisted Surgery, CAS) like robotics, tele-mentoring and tele-presence. ZEUS and da Vinci, present in more than 120 Centres in the world, have been used in many fields of surgery and have been tested in some general surgical procedures. Since the end of 2003, we have performed 70 experimental procedures and 24 operations of general surgery with ZEUS robotic system, after having properly trained 3 surgeons and the operating room staff. Apart from the robot set-up, the mean operative time of the robotic operations was similar to the laparoscopic ones; no complications due to robotic technique occurred. The Authors report benefits and disadvantages related to robots' utilization, problems still to be solved and the possibility to make use of them with tele-surgery, training and virtual surgery.

  10. Robotic surgery for rectal cancer: A systematic review of current practice

    PubMed Central

    Mak, Tony Wing Chung; Lee, Janet Fung Yee; Futaba, Kaori; Hon, Sophie Sok Fei; Ngo, Dennis Kwok Yu; Ng, Simon Siu Man

    2014-01-01

    AIM: To give a comprehensive review of current literature on robotic rectal cancer surgery. METHODS: A systematic review of current literature via PubMed and Embase search engines was performed to identify relevant articles from january 2007 to november 2013. The keywords used were: “robotic surgery”, “surgical robotics”, “laparoscopic computer-assisted surgery”, “colectomy” and “rectal resection”. RESULTS: After the initial screen of 380 articles, 20 papers were selected for review. A total of 1062 patients (male 64.0%) with a mean age of 61.1 years and body mass index of 24.9 kg/m2 were included in the review. Out of 1062 robotic-assisted operations, 831 (78.2%) anterior and low anterior resections, 132 (12.4%) intersphincteric resection with coloanal anastomosis, 98 (9.3%) abdominoperineal resections and 1 (0.1%) Hartmann’s operation were included in the review. Robotic rectal surgery was associated with longer operative time but with comparable oncological results and anastomotic leak rate when compared with laparoscopic rectal surgery. CONCLUSION: Robotic colorectal surgery has continued to evolve to its current state with promising results; feasible surgical option with low conversion rate and comparable short-term oncological results. The challenges faced with robotic surgery are for more high quality studies to justify its cost. PMID:24936229

  11. 42 CFR 1001.1701 - Billing for services of assistant at surgery during cataract operations.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 5 2013-10-01 2013-10-01 false Billing for services of assistant at surgery during... PROGRAMS Permissive Exclusions § 1001.1701 Billing for services of assistant at surgery during cataract... surgery during a cataract operation, or (ii) Charges that include a charge for an assistant at surgery...

  12. 42 CFR 1001.1701 - Billing for services of assistant at surgery during cataract operations.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Billing for services of assistant at surgery during... PROGRAMS Permissive Exclusions § 1001.1701 Billing for services of assistant at surgery during cataract... surgery during a cataract operation, or (ii) Charges that include a charge for an assistant at surgery...

  13. 42 CFR 1001.1701 - Billing for services of assistant at surgery during cataract operations.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 5 2012-10-01 2012-10-01 false Billing for services of assistant at surgery during... PROGRAMS Permissive Exclusions § 1001.1701 Billing for services of assistant at surgery during cataract... surgery during a cataract operation, or (ii) Charges that include a charge for an assistant at surgery...

  14. 42 CFR 1001.1701 - Billing for services of assistant at surgery during cataract operations.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 5 2014-10-01 2014-10-01 false Billing for services of assistant at surgery during... PROGRAMS Permissive Exclusions § 1001.1701 Billing for services of assistant at surgery during cataract... surgery during a cataract operation, or (ii) Charges that include a charge for an assistant at surgery...

  15. 42 CFR 1001.1701 - Billing for services of assistant at surgery during cataract operations.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 5 2011-10-01 2011-10-01 false Billing for services of assistant at surgery during... PROGRAMS Permissive Exclusions § 1001.1701 Billing for services of assistant at surgery during cataract... surgery during a cataract operation, or (ii) Charges that include a charge for an assistant at surgery...

  16. The First Korean Experience of Telemanipulative Robot-Assisted Laparoscopic Cholecystectomy Using the da Vinci System

    PubMed Central

    Kang, Chang Moo; Chi, Hoon Sang; Hyeung, Woo Jin; Kim, Kyung Sik; Choi, Jin Sub; Kim, Byong Ro

    2007-01-01

    With the advancement of laparoscopic instruments and computer sciences, complex surgical procedures are expected to be safely performed by robot assisted telemanipulative laparoscopic surgery. The da Vinci system (Intuitive Surgical, Mountain View, CA, USA) became available at the many surgical fields. The wrist like movements of the instrument's tip, as well as 3-dimensional vision, could be expected to facilitate more complex laparoscopic procedure. Here, we present the first Korean experience of da Vinci robotic assisted laparoscopic cholecystectomy and discuss the introduction and perspectives of this robotic system. PMID:17594166

  17. Medical education as a science: the quality of evidence for computer-assisted instruction.

    PubMed

    Letterie, Gerard S

    2003-03-01

    A marked increase in the number of computer programs for computer-assisted instruction in the medical sciences has occurred over the past 10 years. The quality of both the programs and the literature that describe these programs has varied considerably. The purposes of this study were to evaluate the published literature that described computer-assisted instruction in medical education and to assess the quality of evidence for its implementation, with particular emphasis on obstetrics and gynecology. Reports published between 1988 and 2000 on computer-assisted instruction in medical education were identified through a search of MEDLINE and Educational Resource Identification Center and a review of the bibliographies of the articles that were identified. Studies were selected if they included a description of computer-assisted instruction in medical education, regardless of the type of computer program. Data were extracted with a content analysis of 210 reports. The reports were categorized according to study design (comparative, prospective, descriptive, review, or editorial), type of computer-assisted instruction, medical specialty, and measures of effectiveness. Computer-assisted instruction programs included online technologies, CD-ROMs, video laser disks, multimedia work stations, virtual reality, and simulation testing. Studies were identified in all medical specialties, with a preponderance in internal medicine, general surgery, radiology, obstetrics and gynecology, pediatrics, and pathology. Ninety-six percent of the articles described a favorable impact of computer-assisted instruction in medical education, regardless of the quality of the evidence. Of the 210 reports that were identified, 60% were noncomparative, descriptive reports of new techniques in computer-assisted instruction, and 15% and 14% were reviews and editorials, respectively, of existing technology. Eleven percent of studies were comparative and included some form of assessment of the effectiveness of the computer program. These assessments included pre- and posttesting and questionnaires to score program quality, perceptions of the medical students and/or residents regarding the program, and impact on learning. In one half of these comparative studies, computer-assisted instruction was compared with traditional modes of teaching, such as text and lectures. Six studies compared performance before and after the computer-assisted instruction. Improvements were shown in 5 of the studies. In the remainder of the studies, computer-assisted instruction appeared to result in similar test performance. Despite study design or outcome, most articles described enthusiastic endorsement of the programs by the participants, including medical students, residents, and practicing physicians. Only 1 study included cost analysis. Thirteen of the articles were in obstetrics and gynecology. Computer-assisted instruction has assumed to have an increasing role in medical education. In spite of enthusiastic endorsement and continued improvements in software, few studies of good design clearly demonstrate improvement in medical education over traditional modalities. There are no comparative studies in obstetrics and gynecology that demonstrate a clear-cut advantage. Future studies of computer-assisted instruction that include comparisons and cost assessments to gauge their effectiveness over traditional methods may better define their precise role.

  18. A low-cost multimodal head-mounted display system for neuroendoscopic surgery.

    PubMed

    Xu, Xinghua; Zheng, Yi; Yao, Shujing; Sun, Guochen; Xu, Bainan; Chen, Xiaolei

    2018-01-01

    With rapid advances in technology, wearable devices as head-mounted display (HMD) have been adopted for various uses in medical science, ranging from simply aiding in fitness to assisting surgery. We aimed to investigate the feasibility and practicability of a low-cost multimodal HMD system in neuroendoscopic surgery. A multimodal HMD system, mainly consisted of a HMD with two built-in displays, an action camera, and a laptop computer displaying reconstructed medical images, was developed to assist neuroendoscopic surgery. With this intensively integrated system, the neurosurgeon could freely switch between endoscopic image, three-dimensional (3D) reconstructed virtual endoscopy images, and surrounding environment images. Using a leap motion controller, the neurosurgeon could adjust or rotate the 3D virtual endoscopic images at a distance to better understand the positional relation between lesions and normal tissues at will. A total of 21 consecutive patients with ventricular system diseases underwent neuroendoscopic surgery with the aid of this system. All operations were accomplished successfully, and no system-related complications occurred. The HMD was comfortable to wear and easy to operate. Screen resolution of the HMD was high enough for the neurosurgeon to operate carefully. With the system, the neurosurgeon might get a better comprehension on lesions by freely switching among images of different modalities. The system had a steep learning curve, which meant a quick increment of skill with it. Compared with commercially available surgical assistant instruments, this system was relatively low-cost. The multimodal HMD system is feasible, practical, helpful, and relatively cost efficient in neuroendoscopic surgery.

  19. Immediate loading of four implants (BTLock®) in the maxilla and provisional restoration with guide-surgery (SimPlant, Materialise®): case report

    PubMed Central

    SPINELLI, D.; DE VICO, G.; SCHIAVETTI, R.; BONINO, M.; POZZI, A.; BOLLERO, P.; BARLATTANI, A.

    2010-01-01

    SUMMARY The severe atrophy of the jaws are a challenging therapeutic problem, since the increase in bone is necessary to allow the placement of a sufficient number of implants. Combining immediate functionalization with the concept of guided surgery they combine the advantages offered by the innovative surgical and prosthetic implant technique (All-on-Four®) with those of computer-assisted planning in cases of severe bone atrophy. The method used in this case report, combines these two concepts in a surgical and prosthetic protocol safe and effective for the immediate function of 4 implants to support a fixed prosthesis in completely edentulous subjects. The integration of technology with immediate function with the concept of computer-guided surgery for implant placement and rehabilitation of completely edentulous jaws is now a predictable treatment modality with implant survival comparable to the traditional protocols. PMID:23285381

  20. Video games and surgical ability: a literature review.

    PubMed

    Lynch, Jeremy; Aughwane, Paul; Hammond, Toby M

    2010-01-01

    Surgical training is rapidly evolving because of reduced training hours and the reduction of training opportunities due to patient safety concerns. There is a popular conception that video game usage might be linked to improved operating ability especially those techniques involving endoscopic modalities. If true this might suggest future directions for training. A search was made of the MEDLINE databases for the MeSH term, "Video Games," combined with the terms "Surgical Procedures, Operative," "Endoscopy," "Robotics," "Education," "Learning," "Simulators," "Computer Simulation," "Psychomotor Performance," and "Surgery, Computer-Assisted,"encompassing all journal articles before November 2009. References of articles were searched for further studies. Twelve relevant journal articles were discovered. Video game usage has been studied in relationship to laparoscopic, gastrointestinal endoscopic, endovascular, and robotic surgery. Video game users acquire endoscopic but not robotic techniques quicker, and training on video games appears to improve performance. Copyright (c) 2010 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  1. Conventional plate fixation method versus pre-operative virtual simulation and three-dimensional printing-assisted contoured plate fixation method in the treatment of anterior pelvic ring fracture.

    PubMed

    Hung, Chun-Chi; Li, Yuan-Ta; Chou, Yu-Ching; Chen, Jia-En; Wu, Chia-Chun; Shen, Hsain-Chung; Yeh, Tsu-Te

    2018-05-03

    Treating pelvic fractures remains a challenging task for orthopaedic surgeons. We aimed to evaluate the feasibility, accuracy, and effectiveness of three-dimensional (3D) printing technology and computer-assisted virtual surgery for pre-operative planning in anterior ring fractures of the pelvis. We hypothesized that using 3D printing models would reduce operation time and significantly improve the surgical outcomes of pelvic fracture repair. We retrospectively reviewed the records of 30 patients with pelvic fractures treated by anterior pelvic fixation with locking plates (14 patients, conventional locking plate fixation; 16 patients, pre-operative virtual simulation with 3D, printing-assisted, pre-contoured, locking plate fixation). We compared operative time, instrumentation time, blood loss, and post-surgical residual displacements, as evaluated on X-ray films, among groups. Statistical analyses evaluated significant differences between the groups for each of these variables. The patients treated with the virtual simulation and 3D printing-assisted technique had significantly shorter internal fixation times, shorter surgery duration, and less blood loss (- 57 minutes, - 70 minutes, and - 274 ml, respectively; P < 0.05) than patients in the conventional surgery group. However, the post-operative radiological result was similar between groups (P > 0.05). The complication rate was less in the 3D printing group (1/16 patients) than in the conventional surgery group (3/14 patients). The 3D simulation and printing technique is an effective and reliable method for treating anterior pelvic ring fractures. With precise pre-operative planning and accurate execution of the procedures, this time-saving approach can provide a more personalized treatment plan, allowing for a safer orthopaedic surgery.

  2. Creation of a 3-dimensional virtual dental patient for computer-guided surgery and CAD-CAM interim complete removable and fixed dental prostheses: A clinical report.

    PubMed

    Harris, Bryan T; Montero, Daniel; Grant, Gerald T; Morton, Dean; Llop, Daniel R; Lin, Wei-Shao

    2017-02-01

    This clinical report proposes a digital workflow using 2-dimensional (2D) digital photographs, a 3D extraoral facial scan, and cone beam computed tomography (CBCT) volumetric data to create a 3D virtual patient with craniofacial hard tissue, remaining dentition (including surrounding intraoral soft tissue), and the realistic appearance of facial soft tissue at an exaggerated smile under static conditions. The 3D virtual patient was used to assist the virtual diagnostic tooth arrangement process, providing patient with a pleasing preoperative virtual smile design that harmonized with facial features. The 3D virtual patient was also used to gain patient's pretreatment approval (as a communication tool), design a prosthetically driven surgical plan for computer-guided implant surgery, and fabricate the computer-aided design and computer-aided manufacturing (CAD-CAM) interim prostheses. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  3. Computer aided planning of orthopaedic surgeries: the definition of generic planning steps for bone removal procedures.

    PubMed

    Putzer, David; Moctezuma, Jose Luis; Nogler, Michael

    2017-11-01

    An increasing number of orthopaedic surgeons are using computer aided planning tools for bone removal applications. The aim of the study was to consolidate a set of generic functions to be used for a 3D computer assisted planning or simulation. A limited subset of 30 surgical procedures was analyzed and verified in 243 surgical procedures of a surgical atlas. Fourteen generic functions to be used in 3D computer assisted planning and simulations were extracted. Our results showed that the average procedure comprises 14 ± 10 (SD) steps with ten different generic planning steps and four generic bone removal steps. In conclusion, the study shows that with a limited number of 14 planning functions it is possible to perform 243 surgical procedures out of Campbell's Operative Orthopedics atlas. The results may be used as a basis for versatile generic intraoperative planning software.

  4. Virtual surgical planning and 3D printing in repeat calvarial vault reconstruction for craniosynostosis: technical note.

    PubMed

    LoPresti, Melissa; Daniels, Bradley; Buchanan, Edward P; Monson, Laura; Lam, Sandi

    2017-04-01

    Repeat surgery for restenosis after initial nonsyndromic craniosynostosis intervention is sometimes needed. Calvarial vault reconstruction through a healed surgical bed adds a level of intraoperative complexity and may benefit from preoperative and intraoperative definitions of biometric and aesthetic norms. Computer-assisted design and manufacturing using 3D imaging allows the precise formulation of operative plans in anticipation of surgical intervention. 3D printing turns virtual plans into anatomical replicas, templates, or customized implants by using a variety of materials. The authors present a technical note illustrating the use of this technology: a repeat calvarial vault reconstruction that was planned and executed using computer-assisted design and 3D printed intraoperative guides.

  5. Immediate provisionalization with a CAD/CAM interim abutment and crown: a guided soft tissue healing technique.

    PubMed

    Proussaefs, Periklis

    2015-02-01

    A technique is described in which a single interim abutment and crown were fabricated in advance and placed the day of dental implant surgery. The contours of the interim crown were identical to the contours of a tentatively designed definitive prosthesis and allowed the tissue to heal and obtain contours that accommodated the contours of the definitive prosthesis. After osseointegration was established, a definitive impression was made with a custom computer-assisted design and computer-assisted manufacturing impression coping. The definitive prosthesis then was fabricated. Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  6. Secondary reconstruction of maxillofacial trauma.

    PubMed

    Castro-Núñez, Jaime; Van Sickels, Joseph E

    2017-08-01

    Craniomaxillofacial trauma is one of the most complex clinical conditions in contemporary maxillofacial surgery. Vital structures and possible functional and esthetic sequelae are important considerations following this type of trauma and intervention. Despite the best efforts of the primary surgery, there are a group of patients that will have poor outcomes requiring secondary reconstruction to restore form and function. The purpose of this study is to review current concepts on secondary reconstruction to the maxillofacial complex. The evaluation of a posttraumatic patient for a secondary reconstruction must include an assessment of the different subunits of the upper face, middle face, and lower face. Virtual surgical planning and surgical guides represent the most important innovations in secondary reconstruction over the past few years. Intraoperative navigational surgery/computed-assisted navigation is used in complex cases. Facial asymmetry can be corrected or significantly improved by segmentation of the computerized tomography dataset and mirroring of the unaffected side by means of virtual surgical planning. Navigational surgery/computed-assisted navigation allows for a more precise surgical correction when secondary reconstruction involves the replacement of extensive anatomical areas. The use of technology can result in custom-made replacements and prebent plates, which are more stable and resistant to fracture because of metal fatigue. Careful perioperative evaluation is the key to positive outcomes of secondary reconstruction after trauma. The advent of technological tools has played a capital role in helping the surgical team perform a given treatment plan in a more precise and predictable manner.

  7. Computer assisted uroflowmetry diagnostic system

    NASA Astrophysics Data System (ADS)

    Makal, Jarosław; Idźkowski, Adam; Walendziuk, Wojciech

    2006-10-01

    In this paper an original uroflowmeter (called Adalbertus) has been presented. The device draws the flow chart and measures the parameters of urine flow. It is used in urological surgeries as an assistance in diagnosis of lower urinary track diseases like Benign Prostatic Hyperplasia (BPH). The measuring track and its main part - weight sensor have been described. Also the way of uncertainty calculation is mentioned. An example flow chart has been shown and the achieved results have been compared with a commercial product.

  8. Accuracy of Three-Dimensional Planning in Surgery-First Orthognathic Surgery: Planning Versus Outcome.

    PubMed

    Tran, Ngoc Hieu; Tantidhnazet, Syrina; Raocharernporn, Somchart; Kiattavornchareon, Sirichai; Pairuchvej, Verasak; Wongsirichat, Natthamet

    2018-05-01

    The benefit of computer-assisted planning in orthognathic surgery (OGS) has been extensively documented over the last decade. This study aimed to evaluate the accuracy of three-dimensional (3D) virtual planning in surgery-first OGS. Fifteen patients with skeletal class III malocclusion who underwent bimaxillary OGS with surgery-first approach were included. A composite skull model was reconstructed using data from cone-beam computed tomography and stereolithography from a scanned dental cast. Surgical procedures were simulated using Simplant O&O software, and the virtual plan was transferred to the operation room using 3D-printed splints. Differences of the 3D measurements between the virtual plan and postoperative results were evaluated, and the accuracy was reported using root mean square deviation (RMSD) and the Bland-Altman method. The virtual planning was successfully transferred to surgery. The overall mean linear difference was 0.88 mm (0.79 mm for the maxilla and 1 mm for the mandible), and the overall mean angular difference was 1.16°. The RMSD ranged from 0.86 to 1.46 mm and 1.27° to 1.45°, within the acceptable clinical criteria. In this study, virtual surgical planning and 3D-printed surgical splints facilitated the diagnosis and treatment planning, and offered an accurate outcome in surgery-first OGS.

  9. Robot-Assisted Laparoscopic Repair of Spontaneous Appendicovesical Fistula

    PubMed Central

    Kibar, Yusuf; Yalcin, Serdar; Kopru, Burak; Topuz, Bahadir; Ebiloglu, Turgay

    2016-01-01

    Abstract Background: To report the first case of the spontaneous appendicovesical fistulas' (AVF) repair with robot assisted laparoscopy. Case Presentation: A 29-year-old male patient with urgent persistant bacteriuria and dysuria was referred to our clinic. Physical examination and blood tests were normal. He had used various antibiotics due to recurrent UTI for about 20 years. Computed tomography revealed the fistula tract between the distal end of the appendix and right lateral wall of the bladder dome. He was successfully treated with robot-assisted laparoscopic repair. Following this surgery, the patient's complaints were resolved completely. Conclusion: AVF is the rare condition. Robot-assisted laparoscopy repair of AVF is safe and effective treatment option. PMID:27579435

  10. Computer-assisted teaching of skin flap surgery: validation of a mobile platform software for medical students.

    PubMed

    de Sena, David P; Fabricio, Daniela D; Lopes, Maria Helena I; da Silva, Vinicius D

    2013-01-01

    The purpose of this study was to develop and validate a multimedia software application for mobile platforms to assist in the teaching and learning process of design and construction of a skin flap. Traditional training in surgery is based on learning by doing. Initially, the use of cadavers and animal models appeared to be a valid alternative for training. However, many conflicts with these training models prompted progression to synthetic and virtual reality models. Fifty volunteer fifth- and sixth-year medical students completed a pretest and were randomly allocated into two groups of 25 students each. The control group was exposed for 5 minutes to a standard text-based print article, while the test group used multimedia software describing how to fashion a rhomboid flap. Each group then performed a cutaneous flap on a training bench model while being evaluated by three blinded BSPS (Brazilian Society of Plastic Surgery) board-certified surgeons using the OSATS (Objective Structured Assessment of Technical Skill) protocol and answered a post-test. The text-based group was then tested again using the software. The computer-assisted learning (CAL) group had superior performance as confirmed by checklist scores (p<0.002), overall global assessment (p = 0.017) and post-test results (p<0.001). All participants ranked the multimedia method as the best study tool. CAL learners exhibited better subjective and objective performance when fashioning rhomboid flaps as compared to those taught with standard print material. These findings indicate that students preferred to learn using the multimedia method.

  11. Outcome of video-assisted translumbar retroperitoneal necrosectomy and closed lavage for severe necrotizing pancreatitis.

    PubMed

    Ulagendra Perumal, Srinivasan; Pillai, Sastha Ahanatha; Perumal, Senthilkumar; Sathyanesan, Jeswanth; Palaniappan, Ravichandran

    2014-04-01

    Surgery for necrotizing pancreatitis is associated with a high rate of morbidity and mortality. We present a series of 26 patients who underwent video-assisted translumbar retroperitoneal necrosectomy and analyse their outcomes. Records of 26 patients who underwent video-assisted translumbar retroperitoneal necrosectomy and closed drainage for infected pancreatitic necrosis between January 2008 and March 2012 were reviewed, retrospectively. Twenty-three out of 26 patients were males, with a mean age of 38.6 (±9.9) years. Alcohol was the aetiology in 18 patients, gall stones in 7, and in 1 it was idiopathic. The mean duration of symptoms before patients were taken up for surgery was 47.2 (±34.8) days. The mean computed tomography severity index was 7.7 (±1.2). All patients had undergone video-assisted retroperitoneal necrosectomy through a limited left lumbar incision. Post-operative lavage was given through drains placed in the retroperitoneum. Three patients required re-exploration. Eleven patients developed complications and there were two mortalities. The median intensive care unit (ICU) stay was 4 days (range 2-14 days). The mean post-operative hospital stay was 22.5 (±6.6) days. Video-assisted translumbar retroperitoneal necrosectomy followed by closed lavage of infected pancreatic necrosis in select cases of infected pancreatic necrosis was associated with a low rate of ICU stay, hospital stay and need for re-entry. © 2013 The Authors. ANZ Journal of Surgery © 2013 Royal Australasian College of Surgeons.

  12. Development of a virtual reality training system for endoscope-assisted submandibular gland removal.

    PubMed

    Miki, Takehiro; Iwai, Toshinori; Kotani, Kazunori; Dang, Jianwu; Sawada, Hideyuki; Miyake, Minoru

    2016-11-01

    Endoscope-assisted surgery has widely been adopted as a basic surgical procedure, with various training systems using virtual reality developed for this procedure. In the present study, a basic training system comprising virtual reality for the removal of submandibular glands under endoscope assistance was developed. The efficacy of the training system was verified in novice oral surgeons. A virtual reality training system was developed using existing haptic devices. Virtual reality models were constructed from computed tomography data to ensure anatomical accuracy. Novice oral surgeons were trained using the developed virtual reality training system. The developed virtual reality training system included models of the submandibular gland and surrounding connective tissues and blood vessels entering the submandibular gland. Cutting or abrasion of the connective tissue and manipulations, such as elevation of blood vessels, were reproduced by the virtual reality system. A training program using the developed system was devised. Novice oral surgeons were trained in accordance with the devised training program. Our virtual reality training system for endoscope-assisted removal of the submandibular gland is effective in the training of novice oral surgeons in endoscope-assisted surgery. Copyright © 2016 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  13. [Cost analysis for navigation in knee endoprosthetics].

    PubMed

    Cerha, O; Kirschner, S; Günther, K-P; Lützner, J

    2009-12-01

    Total knee arthroplasty (TKA) is one of the most frequent procedures in orthopaedic surgery. The outcome depends on a range of factors including alignment of the leg and the positioning of the implant in addition to patient-associated factors. Computer-assisted navigation systems can improve the restoration of a neutral leg alignment. This procedure has been established especially in Europe and North America. The additional expenses are not reimbursed in the German DRG system (Diagnosis Related Groups). In the present study a cost analysis of computer-assisted TKA compared to the conventional technique was performed. The acquisition expenses of various navigation systems (5 and 10 year depreciation), annual costs for maintenance and software updates as well as the accompanying costs per operation (consumables, additional operating time) were considered. The additional operating time was determined on the basis of a meta-analysis according to the current literature. Situations with 25, 50, 100, 200 and 500 computer-assisted TKAs per year were simulated. The amount of the incremental costs of the computer-assisted TKA depends mainly on the annual volume and the additional operating time. A relevant decrease of the incremental costs was detected between 50 and 100 procedures per year. In a model with 100 computer-assisted TKAs per year an additional operating time of 14 mins and a 10 year depreciation of the investment costs, the incremental expenses amount to 300-395 depending on the navigation system. Computer-assisted TKA is associated with additional costs. From an economical point of view an amount of more than 50 procedures per year appears to be favourable. The cost-effectiveness could be estimated if long-term results will show a reduction of revisions or a better clinical outcome.

  14. A technical report on video-assisted thoracoscopy in thoracic spinal surgery. Preliminary description.

    PubMed

    Regan, J J; Mack, M J; Picetti, G D

    1995-04-01

    This report is a preliminary description of the efficacy of video-assisted thoracoscopic surgery in thoracic spinal procedures that otherwise require open thoracotomy. This report sought to describe the efficacy of video-assisted thoracoscopic surgery in thoracic spinal procedures that otherwise require open thoracotomy. In a landmark study that compared video-assisted thoracoscopic surgery for peripheral lung lesions with thoracotomy, video-assisted thoracoscopic surgery reduced postoperative pain, improved early shoulder girdle function, and shortened hospital stay. Video-assisted thoracoscopic surgery was performed in 12 thoracic spinal patients (herniated nucleus pulposus, infection, tumor, or spinal deformity) and is described in detail in this report. Video-assisted thoracoscopic surgery in thoracic spinal surgery resulted in little postoperative pain, short intensive care unit and hospital stays, and little or no morbidity. In the short follow-up period, there was no post-thoracotomy pain syndrome nor neurologic sequelae in these patients. Operative time decreased dramatically as experience was gained with the procedure. Given consistently improving surgical skills, a number of thoracic spinal procedures using video-assisted thoracoscopic surgery, including thoracic discectomy, internal rib thoracoplasty, anterior osteotomy, corpectomy, and fusion, can be performed safely with no additional surgical time or risk to the patient.

  15. Application of 3D printing rapid prototyping-assisted percutaneous fixation in the treatment of intertrochanteric fracture.

    PubMed

    Zheng, Sheng-Nai; Yao, Qing-Qiang; Mao, Feng-Yong; Zheng, Peng-Fei; Tian, Shu-Chang; Li, Jia-Yi; Yu, Yi-Fan; Liu, Shuai; Zhou, Jin; Hu, Jun; Xu, Yan; Tang, Kai; Lou, Yue; Wang, Li-Ming

    2017-10-01

    The aim of the present study was to investigate the application of 3D printing (3DP) rapid prototyping (RP) technique-assisted percutaneous fixation in the treatment of femoral intertrochanteric fracture (ITF) using proximal femoral nail anti-rotation (PFNA). A total of 39 patients with unstable ITF were included in the current study. Patients were divided into two groups: 19 patients were examined using computed tomography scanning and underwent PFNA with SDP-RP whereas the other 20 patients underwent conventional PFNA treatment. Anatomical data were converted from the Digital Imaging and Communications in Medicine format to the stereolithography format using M3D software. The 3DP-RP model was established using the fused deposition modeling technique and the length and diameter of the main screw blade was measured during the simulation. The postoperative femoral neck-shaft angle (NSA), surgery duration, intraoperative and postoperative blood loss, and the duration of hospital stay were recorded and compared with the corresponding values in conventional surgery. No significant differences were observed in mean PFNA size between the implants used and the preoperative planning estimates. It was demonstrated that the 3DP-RP assisted procedure resulted in more effective reduction of the NSA. Furthermore, patients undergoing 3DP-RP experienced a significant reduction in duration of surgery (P<0.01), as well as reductions in intraoperative (P=0.02) and postoperative (P=0.03) blood loss, compared with conventional surgery. At 6 months post-surgery, no cases of hip varus/vague deformities or implant failure were observed in patients that underwent either the 3DP-RP-assisted or conventional procedure. The results of the present study suggest that the 3DP-RP technique is able to create an accurate model of the ITF, which facilitates surgical planning and fracture reduction, thus improving the efficiency of PFNA surgery for ITFs.

  16. User Interface Evaluation of a Multimedia CD-ROM for Teaching Minor Skin Surgery

    ERIC Educational Resources Information Center

    Ahmed, Jamil Shaikh; Coughlan, Jane; Edwards, Michael; Morar, Sonali S.

    2009-01-01

    Expert operative information is a prerequisite for any form of surgical training. However, the shortening of working hours has reduced surgical training time and learning opportunities. As a potential solution to this problem, multimedia programs have been designed to provide computer-based assistance to surgical trainees outside of the operating…

  17. 76 FR 15321 - SEDASYS Computer-Assisted Personalized Sedation System; Ethicon Endo-Surgery, Inc.'s, Petition...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-21

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2010-P-0176... of FDA's Denial of Premarket Approval AGENCY: Food and Drug Administration, HHS. ACTION: Notice. SUMMARY: The Food and Drug Administration (FDA) is announcing that it intends to refer for review before...

  18. 76 FR 71980 - SEDASYS Computer-Assisted Personalized Sedation System; Ethicon Endo-Surgery, Incorporated's...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-11-21

    ... Device and Radiological Health's (CDRH's) denial of a premarket approval application (PMA) for the... Committee: To provide advice and recommendations to the Agency on scientific disputes between CDRH and... EES and CDRH may be made to the docket on or before December 7, 2011. Submit electronic comments to...

  19. Augmented reality and image overlay navigation with OsiriX in laparoscopic and robotic surgery: not only a matter of fashion.

    PubMed

    Volonté, Francesco; Pugin, François; Bucher, Pascal; Sugimoto, Maki; Ratib, Osman; Morel, Philippe

    2011-07-01

    New technologies can considerably improve preoperative planning, enhance the surgeon's skill and simplify the approach to complex procedures. Augmented reality techniques, robot assisted operations and computer assisted navigation tools will become increasingly important in surgery and in residents' education. We obtained 3D reconstructions from simple spiral computed tomography (CT) slides using OsiriX, an open source processing software package dedicated to DICOM images. These images were then projected on the patient's body with a beamer fixed to the operating table to enhance spatial perception during surgical intervention (augmented reality). Changing a window's deepness level allowed the surgeon to navigate through the patient's anatomy, highlighting regions of interest and marked pathologies. We used image overlay navigation for laparoscopic operations such cholecystectomy, abdominal exploration, distal pancreas resection and robotic liver resection. Augmented reality techniques will transform the behaviour of surgeons, making surgical interventions easier, faster and probably safer. These new techniques will also renew methods of surgical teaching, facilitating transmission of knowledge and skill to young surgeons.

  20. Experimental validation of A-mode ultrasound acquisition system for computer assisted orthopaedic surgery

    NASA Astrophysics Data System (ADS)

    De Lorenzo, Danilo; De Momi, Elena; Beretta, Elisa; Cerveri, Pietro; Perona, Franco; Ferrigno, Giancarlo

    2009-02-01

    Computer Assisted Orthopaedic Surgery (CAOS) systems improve the results and the standardization of surgical interventions. Anatomical landmarks and bone surface detection is straightforward to either register the surgical space with the pre-operative imaging space and to compute biomechanical parameters for prosthesis alignment. Surface points acquisition increases the intervention invasiveness and can be influenced by the soft tissue layer interposition (7-15mm localization errors). This study is aimed at evaluating the accuracy of a custom-made A-mode ultrasound (US) system for non invasive detection of anatomical landmarks and surfaces. A-mode solutions eliminate the necessity of US images segmentation, offers real-time signal processing and requires less invasive equipment. The system consists in a single transducer US probe optically tracked, a pulser/receiver and an FPGA-based board, which is responsible for logic control command generation and for real-time signal processing and three custom-made board (signal acquisition, blanking and synchronization). We propose a new calibration method of the US system. The experimental validation was then performed measuring the length of known-shape polymethylmethacrylate boxes filled with pure water and acquiring bone surface points on a bovine bone phantom covered with soft-tissue mimicking materials. Measurement errors were computed through MR and CT images acquisitions of the phantom. Points acquisition on bone surface with the US system demonstrated lower errors (1.2mm) than standard pointer acquisition (4.2mm).

  1. A comparative direct cost analysis of pediatric urologic robot-assisted laparoscopic surgery versus open surgery: could robot-assisted surgery be less expensive?

    PubMed

    Rowe, Courtney K; Pierce, Michael W; Tecci, Katherine C; Houck, Constance S; Mandell, James; Retik, Alan B; Nguyen, Hiep T

    2012-07-01

    Cost in healthcare is an increasing and justifiable concern that impacts decisions about the introduction of new devices such as the da Vinci(®) surgical robot. Because equipment expenses represent only a portion of overall medical costs, we set out to make more specific cost comparisons between open and robot-assisted laparoscopic surgery. We performed a retrospective, observational, matched cohort study of 146 pediatric patients undergoing either open or robot-assisted laparoscopic urologic surgery from October 2004 to September 2009 at a single institution. Patients were matched based on surgery type, age, and fiscal year. Direct internal costs from the institution were used to compare the two surgery types across several procedures. Robot-assisted surgery direct costs were 11.9% (P=0.03) lower than open surgery. This cost difference was primarily because of the difference in hospital length of stay between patients undergoing open vs robot-assisted surgery (3.8 vs 1.6 days, P<0.001). Maintenance fees and equipment expenses were the primary contributors to robotic surgery costs, while open surgery costs were affected most by room and board expenses. When estimates of the indirect costs of robot purchase and maintenance were included, open surgery had a lower total cost. There were no differences in follow-up times or complication rates. Direct costs for robot-assisted surgery were significantly lower than equivalent open surgery. Factors reducing robot-assisted surgery costs included: A consistent and trained robotic surgery team, an extensive history of performing urologic robotic surgery, selection of patients for robotic surgery who otherwise would have had longer hospital stays after open surgery, and selection of procedures without a laparoscopic alternative. The high indirect costs of robot purchase and maintenance remain major factors, but could be overcome by high surgical volume and reduced prices as competitors enter the market.

  2. [epiDRB--a new minimally invasive concept for referencing in the field of computer-assisted orthopaedic surgery].

    PubMed

    Ohnsorge, J A K; Weisskopf, M; Siebert, C H

    2005-01-01

    Optoelectronic navigation for computer-assisted orthopaedic surgery (CAOS) is based on a firm connection of bone with passive reflectors or active light-emitting diodes in a specific three-dimensional pattern. Even a so-called "minimally-invasive" dynamic reference base (DRB) requires fixation with screws or clamps via incision of the skin. Consequently an originally percutaneous intervention would unnecessarily be extended to an open procedure. Thus, computer-assisted navigation is rarely applied. Due to their tree-like design most DRB's interfere with the surgeon's actions and therefore are at permanent risk to be accidentally dislocated. Accordingly, the optic communication between the camera and the operative site may repeatedly be interrupted. The aim of the research was the development of a less bulky, more comfortable, stable and safely trackable device that can be fixed truly percutaneously. With engineering support of the industrial partner the radiolucent epiDRB was developed. It can be fixed with two or more pins and gains additional stability from its epicutaneous position. The intraoperative applicability and reliability was experimentally tested. Its low centre of gravity and its flat design allow the device to be located directly in the area of interest. Thanks to its epicutaneous position and its particular shape the epiDRB may perpetually be tracked by the navigation system without hindering the surgeon's actions. Hence, the risk of being displaced by accident is minimised and the line of sight remains unaffected. With the newly developed epiDRB computer-assisted navigation becomes easier and safer to handle even in punctures and other percutaneous procedures at the spine as much as at the extremities without an unproportionate amount of additional trauma. Due to the special design referencing of more than one vertebral body is possible at one time, thus decreasing radiation exposure and increasing efficiency.

  3. Laparoscopic and ultrasound assisted management of gallstone ileus after biliointestinal bypass Case report and a review of literature.

    PubMed

    Zago, Mauro; Bozzo, Samantha; Centurelli, Andrea; Giovanelli, Alessandro; Vasino, Michele Ciocca

    2016-05-24

    To report about an additional case of biliary ileus after bariatric surgery is reported and extensively reviewing the literature on this topic. We reviewed the literature and found three cases of gallstone ileus (GI) that occurred after bariatric surgery. A 41 year old patient presented a GI eight years after a biliointestinal bypass (BIB) for morbid obesity. The patient complained of abdominal pain for two weeks. Computed tomography (CT) and abdominal ultrasound (US) allowed a preoperative diagnosis of GI and planning of surgical strategy. Surgical treatment was carried out through laparoscopic-assisted enterolithotomy alone procedure. This choice is supported discussing the related issues: morbidity, potential recurrence, eventual developing of gallbladder carcinoma. It is the first reported case of GI after BIB preoperatively diagnosed through CT scan and US, and treated with a laparoscopic assisted approach. Additional considerations concerning preoperative diagnosis, surgical strategy, technical details and follow-up can be usefully applied even in non post-bariatric biliary ileus. Biliointestinal bypass, Gallstone ileus, Laparoscopy, Ultrasonography.

  4. 3D printing in orthognathic surgery - A literature review.

    PubMed

    Lin, Hsiu-Hsia; Lonic, Daniel; Lo, Lun-Jou

    2018-07-01

    With the recent advances in three-dimensional (3D) imaging, computer-assisted surgical planning and simulation are now regularly used for analysis of craniofacial structures and improved prediction of surgical outcomes in orthognathic surgery. A variety of patient-specific surgical guides and devices have been designed and manufactured using 3D printing technology, which rapidly gained widespread popularity to improve the outcomes. The article presents an overview of 3D printing technology for state-of-the-art application in orthognathic surgery and discusses the impacts on treatment feasibility and patient outcome. The current available literature regarding the use of 3D printing methods in orthognathic surgery including 3D computer-aided design/computer-aided manufacturing, rapid prototyping, additive manufacturing, 3D printing, 3D printed models, surgical occlusal splints, custom-made guides, templates and fixation plates is reviewed. A Medline, PubMed, ProQuest and ScienceDirect search was performed to find relevant articles over the past 10 years. A total of 318 articles were found, out of which 69 were publications addressing the topic of this study. An additional 9 hand-searched articles were added. From the review, we can conclude that the use of 3D printing methods in orthognathic surgery provide the benefit of optimal functional and aesthetic results, patient satisfaction, and precise translation of the treatment plan. Copyright © 2018. Published by Elsevier B.V.

  5. Comparing conventional and computer-assisted surgery baseplate and screw placement in reverse shoulder arthroplasty.

    PubMed

    Venne, Gabriel; Rasquinha, Brian J; Pichora, David; Ellis, Randy E; Bicknell, Ryan

    2015-07-01

    Preoperative planning and intraoperative navigation technologies have each been shown separately to be beneficial for optimizing screw and baseplate positioning in reverse shoulder arthroplasty (RSA) but to date have not been combined. This study describes development of a system for performing computer-assisted RSA glenoid baseplate and screw placement, including preoperative planning, intraoperative navigation, and postoperative evaluation, and compares this system with a conventional approach. We used a custom-designed system allowing computed tomography (CT)-based preoperative planning, intraoperative navigation, and postoperative evaluation. Five orthopedic surgeons defined common preoperative plans on 3-dimensional CT reconstructed cadaveric shoulders. Each surgeon performed 3 computer-assisted and 3 conventional simulated procedures. The 3-dimensional CT reconstructed postoperative units were digitally matched to the preoperative model for evaluation of entry points, end points, and angulations of screws and baseplate. Values were used to find accuracy and precision of the 2 groups with respect to the defined placement. Statistical analysis was performed by t tests (α = .05). Comparison of the groups revealed no difference in accuracy or precision of screws or baseplate entry points (P > .05). Accuracy and precision were improved with use of navigation for end points and angulations of 3 screws (P < .05). Accuracy of the inferior screw showed a trend of improvement with navigation (P > .05). Navigated baseplate end point precision was improved (P < .05), with a trend toward improved accuracy (P > .05). We conclude that CT-based preoperative planning and intraoperative navigation allow improved accuracy and precision for screw placement and precision for baseplate positioning with respect to a predefined placement compared with conventional techniques in RSA. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  6. Lung surgery

    MedlinePlus

    ... Lung tissue removal; Pneumonectomy; Lobectomy; Lung biopsy; Thoracoscopy; Video-assisted thoracoscopic surgery; VATS ... do surgery on your lungs are thoracotomy and video-assisted thoracoscopic surgery (VATS). Robotic surgery may also ...

  7. 42 CFR 415.190 - Conditions of payment: Assistants at surgery in teaching hospitals.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 3 2011-10-01 2011-10-01 false Conditions of payment: Assistants at surgery in... in Teaching Settings § 415.190 Conditions of payment: Assistants at surgery in teaching hospitals. (a... schedule basis for the services of an assistant at surgery in a teaching hospital. This section is based on...

  8. 42 CFR 415.190 - Conditions of payment: Assistants at surgery in teaching hospitals.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 3 2012-10-01 2012-10-01 false Conditions of payment: Assistants at surgery in... Physician Services in Teaching Settings § 415.190 Conditions of payment: Assistants at surgery in teaching... a fee schedule basis for the services of an assistant at surgery in a teaching hospital. This...

  9. 42 CFR 415.190 - Conditions of payment: Assistants at surgery in teaching hospitals.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 3 2014-10-01 2014-10-01 false Conditions of payment: Assistants at surgery in... Physician Services in Teaching Settings § 415.190 Conditions of payment: Assistants at surgery in teaching... a fee schedule basis for the services of an assistant at surgery in a teaching hospital. This...

  10. 42 CFR 415.190 - Conditions of payment: Assistants at surgery in teaching hospitals.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 3 2010-10-01 2010-10-01 false Conditions of payment: Assistants at surgery in... in Teaching Settings § 415.190 Conditions of payment: Assistants at surgery in teaching hospitals. (a... schedule basis for the services of an assistant at surgery in a teaching hospital. This section is based on...

  11. 42 CFR 415.190 - Conditions of payment: Assistants at surgery in teaching hospitals.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 3 2013-10-01 2013-10-01 false Conditions of payment: Assistants at surgery in... Physician Services in Teaching Settings § 415.190 Conditions of payment: Assistants at surgery in teaching... a fee schedule basis for the services of an assistant at surgery in a teaching hospital. This...

  12. Patient-specific polyetheretherketone facial implants in a computer-aided planning workflow.

    PubMed

    Guevara-Rojas, Godoberto; Figl, Michael; Schicho, Kurt; Seemann, Rudolf; Traxler, Hannes; Vacariu, Apostolos; Carbon, Claus-Christian; Ewers, Rolf; Watzinger, Franz

    2014-09-01

    In the present study, we report an innovative workflow using polyetheretherketone (PEEK) patient-specific implants for esthetic corrections in the facial region through onlay grafting. The planning includes implant design according to virtual osteotomy and generation of a subtraction volume. The implant design was refined by stepwise changing the implant geometry according to soft tissue simulations. One patient was scanned using computed tomography. PEEK implants were interactively designed and manufactured using rapid prototyping techniques. Positioning intraoperatively was assisted by computer-aided navigation. Two months after surgery, a 3-dimensional surface model of the patient's face was generated using photogrammetry. Finally, the Hausdorff distance calculation was used to quantify the overall error, encompassing the failures in soft tissue simulation and implantation. The implant positioning process during surgery was satisfactory. The simulated soft tissue surface and the photogrammetry scan of the patient showed a high correspondence, especially where the skin covered the implants. The mean total error (Hausdorff distance) was 0.81 ± 1.00 mm (median 0.48, interquartile range 1.11). The spatial deviation remained less than 0.7 mm for the vast majority of points. The proposed workflow provides a complete computer-aided design, computer-aided manufacturing, and computer-aided surgery chain for implant design, allowing for soft tissue simulation, fabrication of patient-specific implants, and image-guided surgery to position the implants. Much of the surgical complexity resulting from osteotomies of the zygoma, chin, or mandibular angle might be transferred into the planning phase of patient-specific implants. Copyright © 2014 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  13. Accuracy of robot-assisted pedicle screw placement for adolescent idiopathic scoliosis in the pediatric population.

    PubMed

    Macke, Jeremy J; Woo, Raymund; Varich, Laura

    2016-06-01

    This is a retrospective review of pedicle screw placement in adolescent idiopathic scoliosis (AIS) patients under 18 years of age who underwent robot-assisted corrective surgery. Our primary objective was to characterize the accuracy of pedicle screw placement with evaluation by computed tomography (CT) after robot-assisted surgery in AIS patients. Screw malposition is the most frequent complication of pedicle screw placement and is more frequent in AIS. Given the potential for serious complications, the need for improved accuracy of screw placement has spurred multiple innovations including robot-assisted guidance devices. No studies to date have evaluated this robot-assisted technique using CT exclusively within the AIS population. Fifty patients were included in the study. All operative procedures were performed at a single institution by a single pediatric orthopedic surgeon. We evaluated the grade of screw breach, the direction of screw breach, and the positioning of the patient for preoperative scan (supine versus prone). Of 662 screws evaluated, 48 screws (7.2 %) demonstrated a breach of greater than 2 mm. With preoperative prone position CT scanning, only 2.4 % of screws were found to have this degree of breach. Medial malposition was found in 3 % of screws, a rate which decreased to 0 % with preoperative prone position scanning. Based on our results, we conclude that the proper use of image-guided robot-assisted surgery can improve the accuracy and safety of thoracic pedicle screw placement in patients with adolescent idiopathic scoliosis. This is the first study to evaluate the accuracy of pedicle screw placement using CT assessment in robot-assisted surgical correction of patients with AIS. In our study, the robot-assisted screw misplacement rate was lower than similarly constructed studies evaluating conventional (non-robot-assisted) procedures. If patients are preoperatively scanned in the prone position, the misplacement rate is further decreased.

  14. Video-assisted endocrine neck surgery: state of the art.

    PubMed

    Sessa, Luca; Lombardi, Celestino Pio; De Crea, Carmela; Raffaelli, Marco; Bellantone, Rocco

    2017-06-01

    During the last two decades, several minimally invasive approaches for endocrine neck surgery have been developed. Minimally invasive video-assisted approaches (minimally invasive video-assisted parathyroidectomy and minimally invasive video-assisted thyroidectomy) gained a quite large worldwide diffusion, maybe because these techniques combine the advantages related to the endoscopic magnification with those due to the close similarity with the conventional surgery that makes these surgical approaches reproducible and feasible in different surgical settings. Several comparative studies have demonstrated the advantages of minimally invasive video-assisted neck surgery in terms of reduced postoperative pain, better cosmetic result, and higher patients' satisfaction over the conventional endocrine neck surgery. An accurate patients' selection plays a key role to ensure the success of minimally invasive video-assisted approaches. To date, in selected cases and in experienced Center, minimally invasive video-assisted endocrine neck surgery could be considered the standard treatment or at least a safe and effective surgical option.

  15. Physicians' perspectives of adopting computer-assisted navigation in orthopedic surgery.

    PubMed

    Hsu, Hui-Mei; Chang, I-Chiu; Lai, Ta-Wei

    2016-10-01

    Using Computer-assisted orthopedic navigation surgery system (CAOS) has many advantages but is not mandatory to use during an orthopedic surgery. Therefore, opinions obtained from clinical orthopedists with this system are valuable. This paper integrates technology acceptance model and theory of planned behavior to examine the determinants of continued CAOS use to facilitate user management. Opinions from orthopedists who had used a CAOS for at least two years were collected through a cross-sectional survey to verify the research framework. Follow-up interviews with an expert panel based on their experiences of CAOS were conducted to reason the impacts of factors of the research framework. The results show that factors of "perceived usefulness" and "facilitating condition" determine the intention to continue using CAOS, and "perceived usefulness" was driving by "complexity of task" and "social influence". Additionally, support in practice from high-level managers had an influence on orthopedists' satisfaction after using a CAOS. The aging population is accompanied by the increasing requirements for medical care and medical care attendant expenses, especially in total knee replacement. More precision and improvements on survivorship of patients' artificial joints are needed. This study facilitates suggestions in user management when encountering an obstacle in implementing a CAOS. Based on these findings, scientific and practical implications are then discussed. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  16. The impact of marketing language on patient preference for robot-assisted surgery.

    PubMed

    Dixon, Peter R; Grant, Robert C; Urbach, David R

    2015-02-01

    Robot-assisted surgery is gaining momentum as a new trend in minimally invasive surgery. With limited evidence supporting its use in place of the far less expensive conventional laparoscopic surgery, it has been suggested that marketing pressure is partly responsible for its widespread adoption. The impact of phrases that promote the novelty of robot-assisted surgery on patient decision making has not been investigated. We conducted a discrete choice experiment to elicit preference of partial colectomy technique for a hypothetical diagnosis of colon cancer. A convenience sample of 38 participants in an ambulatory general surgery clinic consented to participate. Each participant made 2 treatment decisions between robot-assisted surgery and conventional laparoscopic surgery, with robot-assisted surgery described as "innovative" and "state-of-the-art" in one of the decisions (marketing frame), and by a disclosure of the uncertainty of available evidence in the other (evidence-based frame). The magnitude of the framing effect was large with 12 of 38 subjects (31.6%, P = .005) selecting robot-assisted surgery in the marketing frame and not the evidence-based frame. This is the first study to our knowledge to demonstrate that words that highlight novelty have an important influence on patient preference for robot-assisted surgery and that use of more neutral language can mitigate this effect. © The Author(s) 2014.

  17. Outpatient follow-up system using a personal computer for patients with hepatocellular carcinoma after surgery.

    PubMed

    Itasaka, H; Matsumata, T; Taketomi, A; Yamamoto, K; Yanaga, K; Takenaka, K; Akazawa, K; Sugimachi, K

    1994-12-01

    A simple outpatient follow-up system was developed with a laptop personal computer to assist management of patients with hepatocellular carcinoma after hepatic resections. Since it is based on a non-relational database program and the graphical user interface of Macintosh operating system, those who are not a specialist of the computer operation can use it. It is helpful to promptly recognize current status and problems of the patients, to diagnose recurrences of the disease and to prevent lost from follow-up cases. A portability of the computer also facilitates utilization of these data everywhere, such as in clinical conferences and laboratories.

  18. Assessment of competence in video-assisted thoracoscopic surgery lobectomy: A Danish nationwide study.

    PubMed

    Petersen, René Horsleben; Gjeraa, Kirsten; Jensen, Katrine; Møller, Lars Borgbjerg; Hansen, Henrik Jessen; Konge, Lars

    2018-04-18

    Competence in video-assisted thoracoscopic surgery lobectomy has previously been established on the basis of numbers of procedures performed, but this approach does not ensure competence. Specific assessment tools, such as the newly developed video-assisted thoracoscopic surgery lobectomy assessment tool, allow for structured and objective assessment of competence. Our aim was to provide validity evidence for the video-assisted thoracoscopic surgery lobectomy assessment tool. Video recordings of 60 video-assisted thoracoscopic surgery lobectomies performed by 18 thoracic surgeons were rated using the video-assisted thoracoscopic surgery lobectomy assessment tool. All 4 centers of thoracic surgery in Denmark participated in the study. Two video-assisted thoracoscopic surgery experts rated the videos. They were blinded to surgeon and center. The total internal consistency reliability Cronbach's alpha was 0.93. Inter-rater reliability between the 2 raters was Pearson's r = 0.71 (P < .001). The mean video-assisted thoracoscopic surgery lobectomy assessment tool scores for the 10 procedures performed by beginners were 22.1 (standard deviation [SD], 8.6) for the 28 procedures performed by the intermediate surgeons, 31.2 (SD, 4.4), and for the 20 procedures performed by experts 35.9 (SD, 2.9) (P < .001). Bonferroni post hoc tests showed that experts were significantly better than intermediates (P < .008) and beginners (P < .001). Intermediates' mean scores were significantly better than beginners (P < .001). The pass/fail standard calculated using the contrasting group's method was 31 points. One of the beginners passed, and 2 experts failed the test. Validity evidence was provided for a newly developed assessment tool for video-assisted thoracoscopic surgery lobectomy (video-assisted thoracoscopic surgery lobectomy assessment tool) in a clinical setting. The discriminatory ability among expert surgeons, intermediate surgeons, and beginners proved highly significant. The video-assisted thoracoscopic surgery lobectomy assessment tool could be an important aid in the future training and certification of thoracic surgeons. Copyright © 2018 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  19. 75 FR 36102 - General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Notice of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-24

    ... will discuss, make recommendations, and vote on premarket approval application for MelaFind, sponsored by MELA Sciences, Inc. MelaFind is a non-invasive computer vision system intended to assist in the... characteristics of melanoma, before a final decision to biopsy has been rendered. MelaFind acquires and displays...

  20. 76 FR 75887 - SEDASYS Computer-Assisted Personalized Sedation System; Ethicon Endo-Surgery, Incorporated's...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-05

    ... advisory committee was slated to discuss the Center for Devices and Radiological Health's (CDRH's) denial..., CDRH issued a letter to EES indicating that PMA P080009 for SEDASYS was not approvable under Sec. 814.44(f) (21 CFR 814.44(f)) because CDRH concluded that the data and information offered in support of...

  1. Accuracy of Three-Dimensional Planning in Surgery-First Orthognathic Surgery: Planning Versus Outcome

    PubMed Central

    Tran, Ngoc Hieu; Tantidhnazet, Syrina; Raocharernporn, Somchart; Kiattavornchareon, Sirichai; Pairuchvej, Verasak; Wongsirichat, Natthamet

    2018-01-01

    Background The benefit of computer-assisted planning in orthognathic surgery (OGS) has been extensively documented over the last decade. This study aimed to evaluate the accuracy of three-dimensional (3D) virtual planning in surgery-first OGS. Methods Fifteen patients with skeletal class III malocclusion who underwent bimaxillary OGS with surgery-first approach were included. A composite skull model was reconstructed using data from cone-beam computed tomography and stereolithography from a scanned dental cast. Surgical procedures were simulated using Simplant O&O software, and the virtual plan was transferred to the operation room using 3D-printed splints. Differences of the 3D measurements between the virtual plan and postoperative results were evaluated, and the accuracy was reported using root mean square deviation (RMSD) and the Bland-Altman method. Results The virtual planning was successfully transferred to surgery. The overall mean linear difference was 0.88 mm (0.79 mm for the maxilla and 1 mm for the mandible), and the overall mean angular difference was 1.16°. The RMSD ranged from 0.86 to 1.46 mm and 1.27° to 1.45°, within the acceptable clinical criteria. Conclusion In this study, virtual surgical planning and 3D-printed surgical splints facilitated the diagnosis and treatment planning, and offered an accurate outcome in surgery-first OGS. PMID:29581806

  2. An intelligent interactive simulator of clinical reasoning in general surgery.

    PubMed Central

    Wang, S.; el Ayeb, B.; Echavé, V.; Preiss, B.

    1993-01-01

    We introduce an interactive computer environment for teaching in general surgery and for diagnostic assistance. The environment consists of a knowledge-based system coupled with an intelligent interface that allows users to acquire conceptual knowledge and clinical reasoning techniques. Knowledge is represented internally within a probabilistic framework and externally through a interface inspired by Concept Graphics. Given a set of symptoms, the internal knowledge framework computes the most probable set of diseases as well as best alternatives. The interface displays CGs illustrating the results and prompting essential facts of a medical situation or a process. The system is then ready to receive additional information or to suggest further investigation. Based on the new information, the system will narrow the solutions with increased belief coefficients. PMID:8130508

  3. Unskilled unawareness and the learning curve in robotic spine surgery.

    PubMed

    Schatlo, Bawarjan; Martinez, Ramon; Alaid, Awad; von Eckardstein, Kajetan; Akhavan-Sigari, Reza; Hahn, Anina; Stockhammer, Florian; Rohde, Veit

    2015-10-01

    Robotic assistance for the placement of pedicle screws has been established as a safe technique. Nonetheless rare instances of screw misplacement have been reported.The aim of the present retrospective study is to assess whether experience and time affect the accuracy of screws placed with the help of the SpineAssist™ robot system. Postoperative computed tomography (CT) scans of 258 patients requiring thoracolumbar pedicle screw instrumentation from 2008 to 2013 were reviewed. Overall, 13 surgeons performed the surgeries. A pedicle breach of >3 mm was graded as a misplacement. Surgeons were dichotomised into an early and experienced period in increments of five surgeries. In 258 surgeries, 1,265 pedicle screws were placed with the aid of the robot system. Overall, 1,217 screws (96.2 %) were graded as acceptable. When displayed by surgeon, the development of percent misplacement rates peaked between 5 and 25 surgeries in 12 of 13 surgeons. The overall misplacement rate in the first five surgeries was 2.4 % (6/245). The misplacement rate rose to 6.3 % between 11 and 15 surgeries (10/158; p = 0.20), and reached a significant peak between 16 and 20 surgeries with a rate of 7.1 % (8/112; p = 0.03). Afterwards, misplacement rates declined. A major peak in screw inaccuracies occurred between cases 10 and 20, and a second, smaller one at about 40 surgeries. One potential explanation could be a transition from decreased supervision (unskilled but aware) to increased confidence of a surgeon (unskilled but unaware) who adopts this new technique prior to mastering it (skilled). We therefore advocate ensuring competent supervision for new surgeons at least during the first 25 procedures of robotic spine surgery to optimise the accuracy of robot-assisted pedicle screws.

  4. Three-dimensional fluoroscopic navigation-assisted surgery for tumors in patients with tumor-induced osteomalacia in the bones.

    PubMed

    Kobayashi, Hiroshi; Akiyama, Toru; Okuma, Tomotake; Shinoda, Yusuke; Oka, Hiroyuki; Ito, Nobuaki; Fukumoto, Seiji; Tanaka, Sakae; Kawano, Hirotaka

    2017-12-01

    Tumor-induced osteomalacia (TIO) is a rare paraneoplastic syndrome usually caused by phosphaturic mesenchymal tumors. Segmental resection has been recommended for these tumors in the bones because curettage was found to be associated with a high local recurrence rate. Navigation-assisted surgery provides radiological information to guide the surgeon during surgery. No previous study has reported on the efficacy of navigation-assisted surgery for tumors in patients with TIO. Therefore, the present study aimed to evaluate the efficacy of navigation-assisted surgery for tumors in patients with TIO. The study included seven patients with TIO who were treated between January 2003 and December 2014 at our hospital. All patients underwent surgical treatment with or without the use of a 3-dimensional (3D) fluoroscopy-based navigation system. The laboratory data and oncological outcomes were evaluated. The follow-up period was 8-128 months. The tumors were located at the femur (n = 4), ischium, spine and ilium (n = 1). Of the seven patients, five underwent navigation-assisted surgery and two underwent surgery without navigation assistance. In the two patients who underwent surgery without navigation assistance, a complete cure was not obtained and osteomalacia did not resolve. One of these two patients and the other five patients who underwent navigation-assisted surgery, one patient had incomplete resection due to massive invasion of the tumor into the spinal canal, but five patients achieved complete excision and recovered from osteomalacia. Navigation-assisted surgery using a 3D fluoroscopy-based navigation system is effective for tumors in patients with TIO.

  5. Real-time 3D image reconstruction guidance in liver resection surgery

    PubMed Central

    Nicolau, Stephane; Pessaux, Patrick; Mutter, Didier; Marescaux, Jacques

    2014-01-01

    Background Minimally invasive surgery represents one of the main evolutions of surgical techniques. However, minimally invasive surgery adds difficulty that can be reduced through computer technology. Methods From a patient’s medical image [US, computed tomography (CT) or MRI], we have developed an Augmented Reality (AR) system that increases the surgeon’s intraoperative vision by providing a virtual transparency of the patient. AR is based on two major processes: 3D modeling and visualization of anatomical or pathological structures appearing in the medical image, and the registration of this visualization onto the real patient. We have thus developed a new online service, named Visible Patient, providing efficient 3D modeling of patients. We have then developed several 3D visualization and surgical planning software tools to combine direct volume rendering and surface rendering. Finally, we have developed two registration techniques, one interactive and one automatic providing intraoperative augmented reality view. Results From January 2009 to June 2013, 769 clinical cases have been modeled by the Visible Patient service. Moreover, three clinical validations have been realized demonstrating the accuracy of 3D models and their great benefit, potentially increasing surgical eligibility in liver surgery (20% of cases). From these 3D models, more than 50 interactive AR-assisted surgical procedures have been realized illustrating the potential clinical benefit of such assistance to gain safety, but also current limits that automatic augmented reality will overcome. Conclusions Virtual patient modeling should be mandatory for certain interventions that have now to be defined, such as liver surgery. Augmented reality is clearly the next step of the new surgical instrumentation but remains currently limited due to the complexity of organ deformations during surgery. Intraoperative medical imaging used in new generation of automated augmented reality should solve this issue thanks to the development of Hybrid OR. PMID:24812598

  6. Shape Optimization of the Assisted Bi-directional Glenn surgery for stage-1 single ventricle palliation

    NASA Astrophysics Data System (ADS)

    Verma, Aekaansh; Shang, Jessica; Esmaily-Moghadam, Mahdi; Wong, Kwai; Marsden, Alison

    2016-11-01

    Babies born with a single functional ventricle typically undergo three open-heart surgeries starting as neonates. The first of these stages (BT shunt or Norwood) has the highest mortality rates of the three, approaching 30%. Proceeding directly to a stage-2 Glenn surgery has historically demonstrated inadequate pulmonary flow (PF) & high mortality. Recently, the Assisted Bi-directional Glenn (ABG) was proposed as a promising means to achieve a stable physiology by assisting the PF via an 'ejector pump' from the systemic circulation. We present preliminary parametrization and optimization results for the ABG geometry, with the goal of increasing PF. To limit excessive pressure increases in the Superior Vena Cava (SVC), the SVC pressure is included as a constraint. We use 3-D finite element flow simulations coupled with a single ventricle lumped parameter network to evaluate PF & the pressure constraint. We employ a derivative free optimization method- the Surrogate Management Framework, in conjunction with the OpenDIEL framework to simulate multiple simultaneous evaluations. Results show that nozzle diameter is the most important design parameter affecting ABG performance. The application of these results to patient specific situations will be discussed. This work was supported by an NSF CAREER award (OCI1150184) and by the XSEDE National Computing Resource.

  7. Experiments on robot-assisted navigated drilling and milling of bones for pedicle screw placement.

    PubMed

    Ortmaier, T; Weiss, H; Döbele, S; Schreiber, U

    2006-12-01

    This article presents experimental results for robot-assisted navigated drilling and milling for pedicle screw placement. The preliminary study was carried out in order to gain first insights into positioning accuracies and machining forces during hands-on robotic spine surgery. Additionally, the results formed the basis for the development of a new robot for surgery. A simplified anatomical model is used to derive the accuracy requirements. The experimental set-up consists of a navigation system and an impedance-controlled light-weight robot holding the surgical instrument. The navigation system is used to position the surgical instrument and to compensate for pose errors during machining. Holes are drilled in artificial bone and bovine spine. A quantitative comparison of the drill-hole diameters was achieved using a computer. The interaction forces and pose errors are discussed with respect to the chosen machining technology and control parameters. Within the technological boundaries of the experimental set-up, it is shown that the accuracy requirements can be met and that milling is superior to drilling. It is expected that robot assisted navigated surgery helps to improve the reliability of surgical procedures. Further experiments are necessary to take the whole workflow into account. Copyright 2006 John Wiley & Sons, Ltd.

  8. A navigated mechatronic system with haptic features to assist in surgical interventions.

    PubMed

    Pieck, S; Gross, I; Knappe, P; Kuenzler, S; Kerschbaumer, F; Wahrburg, J

    2003-01-01

    In orthopaedic surgery, the development of new computer-based technologies such as navigation systems and robotics will facilitate more precise, reproducible results in surgical interventions. There are already commercial systems available for clinical use, though these still have some limitations and drawbacks. This paper presents an alternative approach to a universal modular surgical assistant system for supporting less or minimally invasive surgery. The position of a mechatronic arm, which is part of the system, is controlled by a navigation system so that small patient movements are automatically detected and compensated for in real time. Thus, the optimal tool position can be constantly maintained without the need for rigid bone or patient fixation. Furthermore, a force control mode of the mechatronic assistant system, based on a force-torque sensor, not only increases safety during surgical interventions but also facilitates hand-driven direct positioning of the arm. A prototype has been successfully tested in clinical applications at the Orthopadische Universitätsklinik Frankfurt. For the first time worldwide, implantation of the cup prosthesis in total hip replacement surgery has been carried out with the assistance of a mechatronic arm. According to measurements by the digitizing system, operating tool angle deviation remained below 0.5 degrees, relative to the preoperative planning. The presented approach to a new kind of surgical mechatronic assistance system supports the surgeon as needed by optimal positioning of the surgical instruments. Due to its modular design, it is applicable to a wide range of tasks in surgical interventions, e.g., endoscope guidance, bone preparation, etc.

  9. [RESEARCH PROGRESS OF PERIPHERAL NERVE SURGERY ASSISTED BY Da Vinci ROBOTIC SYSTEM].

    PubMed

    Shen, Jie; Song, Diyu; Wang, Xiaoyu; Wang, Changjiang; Zhang, Shuming

    2016-02-01

    To summarize the research progress of peripheral nerve surgery assisted by Da Vinci robotic system. The recent domestic and international articles about peripheral nerve surgery assisted by Da Vinci robotic system were reviewed and summarized. Compared with conventional microsurgery, peripheral nerve surgery assisted by Da Vinci robotic system has distinctive advantages, such as elimination of physiological tremors and three-dimensional high-resolution vision. It is possible to perform robot assisted limb nerve surgery using either the traditional brachial plexus approach or the mini-invasive approach. The development of Da Vinci robotic system has revealed new perspectives in peripheral nerve surgery. But it has still been at the initial stage, more basic and clinical researches are still needed.

  10. Risk-benefit analysis of navigation techniques for vertebral transpedicular instrumentation: a prospective study.

    PubMed

    Noriega, David C; Hernández-Ramajo, Rubén; Rodríguez-Monsalve Milano, Fiona; Sanchez-Lite, Israel; Toribio, Borja; Ardura, Francisco; Torres, Ricardo; Corredera, Raul; Kruger, Antonio

    2017-01-01

    Pedicle screws in spinal surgery have allowed greater biomechanical stability and higher fusion rates. However, malposition is very common and may cause neurologic, vascular, and visceral injuries and compromise mechanical stability. The purpose of this study was to compare the malposition rate between intraoperative computed tomography (CT) scan assisted-navigation and free-hand fluoroscopy-guided techniques for placement of pedicle screw instrumentation. This is a prospective, randomized, observational study. A total of 114 patients were included: 58 in the assisted surgery group and 56 in the free-hand fluoroscopy-guided surgery group. Analysis of screw position was assessed using the Heary classification. Breach severity was defined according to the Gertzbein classification. Radiation doses were evaluated using thermoluminescent dosimeters, and estimates of effective and organ doses were made based on scan technical parameters. Consecutive patients with degenerative disease, who underwent surgical procedures using the free-hand, or intraoperative navigation technique for placement of transpedicular instrumentation, were included in the study. Forty-four out of 625 implanted screws were malpositioned: 11 (3.6%) in the navigated surgery group and 33 (10.3%) in the free-hand group (p<.001). Screw position according to the Heary scale was Grade II (4 navigated surgery, 6 fluoroscopy guided), Grade III (3 navigated surgery, 11 fluoroscopy guided), Grade IV (4 navigated surgery, 16 fluoroscopy guided), and Grade V (1 fluoroscopy guided). There was only one symptomatic case in the conventional surgery group. Breach severity was seven Grade A and four Grade B in the navigated surgery group, and eight Grade A, 24 Grade B, and one Grade C in free-hand fluoroscopy-guided surgery group. Radiation received per patient was 5.8 mSv (4.8-7.3). The median dose received in the free-hand fluoroscopy group was 1 mGy (0.8-1.1). There was no detectable radiation level in the navigation-assisted surgery group, whereas the effective dose was 10 µGy in the free-hand fluoroscopy-guided surgery group. Malposition rate, both symptomatic and asymptomatic, in spinal surgery is reduced when using CT-guided placement of transpedicular instrumentation compared with placement under fluoroscopic guidance, with radiation values within the safety limits for health. Larger studies are needed to determine risk-benefit in these patients. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. 42 CFR 414.52 - Payment for physician assistants' services.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... in paragraph (d) of this section. (a) For assistant-at-surgery services, 65 percent of the amount that would be allowed under the physician fee schedule if the assistant-at-surgery service was furnished by a physician. (b) For services (other than assistant-at-surgery services) furnished in a...

  12. 42 CFR 414.52 - Payment for physician assistants' services.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... in paragraph (d) of this section. (a) For assistant-at-surgery services, 65 percent of the amount that would be allowed under the physician fee schedule if the assistant-at-surgery service was furnished by a physician. (b) For services (other than assistant-at-surgery services) furnished in a...

  13. 42 CFR 414.52 - Payment for physician assistants' services.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... specified in paragraph (d) of this section. (a) For assistant-at-surgery services, 65 percent of the amount that would be allowed under the physician fee schedule if the assistant-at-surgery service was furnished by a physician. (b) For services (other than assistant-at-surgery services) furnished in a...

  14. 42 CFR 414.52 - Payment for physician assistants' services.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... specified in paragraph (d) of this section. (a) For assistant-at-surgery services, 65 percent of the amount that would be allowed under the physician fee schedule if the assistant-at-surgery service was furnished by a physician. (b) For services (other than assistant-at-surgery services) furnished in a...

  15. 42 CFR 414.52 - Payment for physician assistants' services.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... specified in paragraph (d) of this section. (a) For assistant-at-surgery services, 65 percent of the amount that would be allowed under the physician fee schedule if the assistant-at-surgery service was furnished by a physician. (b) For services (other than assistant-at-surgery services) furnished in a...

  16. Relationship between coracoacromial arch and rotator cuff analysed by a computer-assisted method.

    PubMed

    Casino, Daniela; Bruni, Danilo; Zaffagnini, Stefano; Martelli, Sandra; Visani, Andrea; Alvarez, Pau Golanò; Marcacci, Maurilio

    2008-06-01

    In this paper we describe and assess the feasibility of a computer-assisted method which could be useful to investigate the mechanism of subacromial impingment of the shoulder. The relationship between the infraspinatus and supraspinatus and the coracoacromial (CA) arch during passive elevation and abduction are described. The methodology is based on the use of a tracker for recording surfaces and passive movements and data elaboration using dedicated software. In four cadavers, we observed that the minimal distances between the rotator cuff insertions and CA arch were realized at 45 degrees abduction between the acromion and infraspinatus, at 50-90 degrees elevation between the acromion and supraspinatus and also at 45-70 degrees abduction between the CA ligament and supraspinatus. This study showed that the proposed method is able to provide repeatable kinematic data (ICC > or = 0.90), numerical anatomical data comparable with the literature and, moreover, individual measurements on the shoulder joint. This preliminary results support the extension of the methodology to an in vivo protocol to be used during computer-assisted arthroscopic surgery. (c) 2008 John Wiley & Sons, Ltd.

  17. The role of telementoring and telerobotic assistance in the provision of laparoscopic colorectal surgery in rural areas.

    PubMed

    Sebajang, H; Trudeau, P; Dougall, A; Hegge, S; McKinley, C; Anvari, M

    2006-09-01

    The aim of this study was to assess whether telementoring and telerobotic assistance would improve the range and quality of laparoscopic colorectal surgery being performed by community surgeons. We present a series of 18 patients who underwent telementored or telerobotically assisted laparoscopic colorectal surgery in two community hospitals between December 2002 and December 2003. Four community surgeons with no formal advanced laparoscopic fellowship were remotely mentored and assisted by an expert surgeon from a tertiary care center. Telementoring was achieved with real-time two-way audio-video communications over bandwidths of 384 kbps-1.2 mbps and included one redo ileocolic resection, two right hemicolectomies, two sigmoid resections, three low anterior resections, one subtotal colectomy, one reversal of a Hartmann operation, and one abdominoperineal resection. A Zeus TS microjoint system (Computer Motion Inc, Santa Barbara CA) was used to provide telepresence for the telerobotically assisted laparoscopic procedures, which included three right hemicolectomies, three sigmoid resections, and one low anterior resection. There were no major intraoperative complications. There were two minor intraoperative complications involving serosal tears of the colon from the robotic graspers. In the telementored cases, there were two postoperative complications requiring reoperation (intra-abdominal bleeding and small bowel obstruction). Two telementored procedures were converted because of the mentee's inability to find the appropriate planes of dissection. One telerobotically assisted procedure was completed laparoscopically by the local surgeon with aid of telementoring because of inadequate robotic arm position. The median length of hospital stay for this series was 4 days. The surgeons considered telementoring useful in all cases (median score 4 out of 5). The use of remote telerobotic assistance was also considered a significant enabling tool. Telementoring and remote telerobotic assistance are excellent tools for supporting community surgeons and providing patients better access to advanced surgical care.

  18. Needlescopic video-assisted thoracic surgery for primary spontaneous pneumothorax.

    PubMed

    Chou, Shah-Hwa; Li, Hsien-Pin; Lee, Jui-Ying; Lee, Yen-Lung; Kao, Eing-Long; Huang, Meei-Feng; Lin, Tsun-En

    2009-01-01

    Minimally invasive surgery is the current trend of approach in various fields. Since May 2006, our team has started implementing needlescopic video-assisted thoracic surgery as the standard surgical treatment for primary spontaneous pneumothorax. During a seventeen-month period, 62 consecutive patients with primary spontaneous pneumothorax were operated on. The ages, sex ratio, operative times, blood loss, postoperative pain in visual analog scale (VAS), length of stay and hospital costs were recorded and compared with that of another 62 consecutive patients who received conventional video-assisted thoracic surgery between July 2004 and April 2006. Only the postoperative pain in VAS was significantly lower in the needlescopic video-assisted thoracic surgery group; the rest remained the same. Also the wounds were almost undetectable in the needlescopic video-assisted thoracic surgery patients. There were no major complications, mortality or recurrence in either group. Needlescopic video-assisted thoracic surgery is a high-tech technique which provides safety, effectiveness, economy and outcome comparable to that of conventional techniques. It is also associated with less pain and better cosmetics.

  19. The advantages of advanced computer-assisted diagnostics and three-dimensional preoperative planning on implant position in orbital reconstruction.

    PubMed

    Jansen, Jesper; Schreurs, Ruud; Dubois, Leander; Maal, Thomas J J; Gooris, Peter J J; Becking, Alfred G

    2018-04-01

    Advanced three-dimensional (3D) diagnostics and preoperative planning are the first steps in computer-assisted surgery (CAS). They are an integral part of the workflow, and allow the surgeon to adequately assess the fracture and to perform virtual surgery to find the optimal implant position. The goal of this study was to evaluate the accuracy and predictability of 3D diagnostics and preoperative virtual planning without intraoperative navigation in orbital reconstruction. In 10 cadaveric heads, 19 complex orbital fractures were created. First, all fractures were reconstructed without preoperative planning (control group) and at a later stage the reconstructions were repeated with the help of preoperative planning. Preformed titanium mesh plates were used for the reconstructions by two experienced oral and maxillofacial surgeons. The preoperative virtual planning was easily accessible for the surgeon during the reconstruction. Computed tomographic scans were obtained before and after creation of the orbital fractures and postoperatively. Using a paired t-test, implant positioning accuracy (translation and rotations) of both groups were evaluated by comparing the planned implant position with the position of the implant on the postoperative scan. Implant position improved significantly (P < 0.05) for translation, yaw and roll in the group with preoperative planning (Table 1). Pitch did not improve significantly (P = 0.78). The use of 3D diagnostics and preoperative planning without navigation in complex orbital wall fractures has a positive effect on implant position. This is due to a better assessment of the fracture, the possibility of virtual surgery and because the planning can be used as a virtual guide intraoperatively. The surgeon has more control in positioning the implant in relation to the rim and other bony landmarks. Copyright © 2018 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  20. 4D motion modeling of the coronary arteries from CT images for robotic assisted minimally invasive surgery

    NASA Astrophysics Data System (ADS)

    Zhang, Dong Ping; Edwards, Eddie; Mei, Lin; Rueckert, Daniel

    2009-02-01

    In this paper, we present a novel approach for coronary artery motion modeling from cardiac Computed Tomography( CT) images. The aim of this work is to develop a 4D motion model of the coronaries for image guidance in robotic-assisted totally endoscopic coronary artery bypass (TECAB) surgery. To utilize the pre-operative cardiac images to guide the minimally invasive surgery, it is essential to have a 4D cardiac motion model to be registered with the stereo endoscopic images acquired intraoperatively using the da Vinci robotic system. In this paper, we are investigating the extraction of the coronary arteries and the modelling of their motion from a dynamic sequence of cardiac CT. We use a multi-scale vesselness filter to enhance vessels in the cardiac CT images. The centerlines of the arteries are extracted using a ridge traversal algorithm. Using this method the coronaries can be extracted in near real-time as only local information is used in vessel tracking. To compute the deformation of the coronaries due to cardiac motion, the motion is extracted from a dynamic sequence of cardiac CT. Each timeframe in this sequence is registered to the end-diastole timeframe of the sequence using a non-rigid registration algorithm based on free-form deformations. Once the images have been registered a dynamic motion model of the coronaries can be obtained by applying the computed free-form deformations to the extracted coronary arteries. To validate the accuracy of the motion model we compare the actual position of the coronaries in each time frame with the predicted position of the coronaries as estimated from the non-rigid registration. We expect that this motion model of coronaries can facilitate the planning of TECAB surgery, and through the registration with real-time endoscopic video images it can reduce the conversion rate from TECAB to conventional procedures.

  1. Minimally Invasive Spinal Surgery with Intraoperative Image-Guided Navigation

    PubMed Central

    Kim, Terrence T.; Johnson, J. Patrick; Pashman, Robert; Drazin, Doniel

    2016-01-01

    We present our perioperative minimally invasive spine surgery technique using intraoperative computed tomography image-guided navigation for the treatment of various lumbar spine pathologies. We present an illustrative case of a patient undergoing minimally invasive percutaneous posterior spinal fusion assisted by the O-arm system with navigation. We discuss the literature and the advantages of the technique over fluoroscopic imaging methods: lower occupational radiation exposure for operative room personnel, reduced need for postoperative imaging, and decreased revision rates. Most importantly, we demonstrate that use of intraoperative cone beam CT image-guided navigation has been reported to increase accuracy. PMID:27213152

  2. Video-Assisted Thoracoscopic Resection of a Noninvasive Thymoma in a Cat with Myasthenia Gravis Using Low-Pressure Carbon Dioxide Insufflation.

    PubMed

    Griffin, Maureen A; Sutton, Jessie S; Hunt, Geraldine B; Pypendop, Bruno H; Mayhew, Philipp D

    2016-11-01

    To report the use of low-pressure carbon dioxide insufflation during video-assisted thoracoscopic surgery for resection of a noninvasive thymoma in a cat with secondary myasthenia gravis. Clinical case report. Client-owned cat. An 11-year-old castrated male domestic shorthair cat was examined for generalized weakness, voice change, hypersalivation, hyporexia, vomiting, coughing, and gagging. Thoracic ultrasound revealed a cranial mediastinal mass for which cytology was consistent with a thymoma (or lymphoid tissue). Acetylcholine receptor antibody concentration was elevated at 3.16 mmol/L (reference interval < 0.3 mmol/L). Thoracic computed tomography showed two round, contrast-enhancing structures in the cranioventral mediastinum identified as the sternal lymph node and a cranial mediastinal mass (11 × 17 × 24 mm). A presumptive diagnosis of thymoma with paraneoplastic myasthenia gravis was made and surgical resection of both mediastinal masses was recommended. Video-assisted thoracoscopic resection of the cranial mediastinal mass and sternal lymph node were performed with low-pressure carbon dioxide insufflation maintained at an intrathoracic pressure of 2-3 mmHg. The cat recovered from surgery without serious complications. Nineteen months after surgery, the cat developed hind limb stiffness. Thoracic radiographs ruled out a cranial mediastinal mass or megaesophagus. Acetylcholine receptor antibody concentration remained elevated at 2.72 mmol/L. Low-pressure thoracic insufflation facilitated video-assisted thoracoscopic resection of cranial mediastinal masses in this cat. © Copyright 2016 by The American College of Veterinary Surgeons.

  3. Association between robot-assisted surgery and resection quality in patients with colorectal cancer.

    PubMed

    Fransgaard, Tina; Pinar, Ismail; Thygesen, Lau Caspar; Gögenur, Ismail

    2018-06-01

    Resection quality after robot-assisted surgery for colorectal cancer have not previously been investigated in a nationwide study. The aim of the study was to examine the resection quality in robot-assisted versus laparoscopic surgery for colorectal cancer. Furthermore, 30-day mortality, postoperative complications, and conversion to open surgery were investigated. Patients undergoing either laparoscopic or robot-assisted surgery for colorectal cancer between 1 January 2010 and 31 December 2015 were included. The primary outcome was whether R0 resection was achieved. Secondary outcomes were 30-day mortality, postoperative complications, and conversions to laparotomy. A total of 8615 and 3934 patients had a diagnosis of colon cancer and rectal cancer respectively. Of the patients with colon cancer, 511 patients underwent robot-assisted surgery and of the patients with rectal cancer, 706 patients underwent robot-assisted surgery. In the multivariate analysis, patients with colon cancer had an odds ratio (OR) = 0.63 (95%CI 0.45-0.88) for receiving R0 resection in the robot-assisted group compared to laparoscopy. For patients with rectal cancer, the OR was 1.20 (95%CI 0.89-1.61). No difference in 30-day mortality or postoperative complications were observed. The OR of conversion to laparotomy was lower in the robot-assisted group compared to the laparoscopic group in both patients with colon - and rectal cancer. The study showed significant lower odds of receiving R0 resection in patients with colon cancer undergoing robot-assisted surgery. In patients with rectal cancer the robot-assisted surgery non-significantly increased the odds of receiving R0 resection. Copyright © 2018 Elsevier Ltd. All rights reserved.

  4. Accuracy of computer-guided surgery for dental implant placement in fully edentulous patients: A systematic review

    PubMed Central

    Marlière, Daniel Amaral Alves; Demétrio, Maurício Silva; Picinini, Leonardo Santos; De Oliveira, Rodrigo Guerra; Chaves Netto, Henrique Duque De Miranda

    2018-01-01

    Assess clinical studies regarding accuracy between virtual planning of computer-guided surgery and actual outcomes of dental implant placements in total edentulous alveolar ridges. A PubMed search was performed to identify only clinical studies published between 2011 and 2016, searching the following combinations of keywords: “Accuracy AND Computer-Assisted Surgery AND Dental Implants.” Study designs were identified using the terms: Case Reports, Clinical study, Randomized Controlled Trial, Systematic Reviews, Meta-Analysis, humans. Level of agreement between the authors in the study selection process was substantial (k = 0.767), and the study eligibility was considered excellent (k = 0.863). Seven articles were included in this review. They describe the use of bone and muco-supported guides, demonstrating angular deviations cervically and apically ranging from (minimum and maximum means), respectively, 1.85–8.4 (°), 0.17–2.17 (mm), and 0.77–2.86 (mm). Angular deviations obtained most inaccuracy in maxila. For cervical and apical deviations, accuracy was preponderantly lower in maxilla. Despite the similar deviations measurement approaches described, clinical relevance of this study may be useful to warn the surgeon that safety margins in clinical situations. PMID:29657542

  5. Robot-Assisted Thoracic Surgery (RATS): Perioperative Nursing Professional Development Program.

    PubMed

    Sarmanian, Julie D

    2015-09-01

    Robot-assisted surgery continues to grow in popularity worldwide. Competency and training of personnel for robot-assisted thoracic surgery (RATS) is less established compared with other robot-assisted specialties. Major differences between minimally invasive approaches to thoracic surgery (eg, video-assisted thoracoscopic surgery) and RATS are presented to address a paucity of literature on the subject. Although perioperative nursing considerations are universal to all robot-assisted procedures, there are nursing consideration specific to RATS. This article provides a RATS perioperative nursing development program for RN circulators and scrub personnel. Development of perioperative nursing knowledge and skills through implementation of targeted training programs enables nurses to provide a safe surgical experience for patients undergoing RATS. Copyright © 2015 AORN, Inc. Published by Elsevier Inc. All rights reserved.

  6. Management of severe ischemic cardiomyopathy: left ventricular assist device as destination therapy versus conventional bypass and mitral valve surgery.

    PubMed

    Maltais, Simon; Tchantchaleishvili, Vahtang; Schaff, Hartzell V; Daly, Richard C; Suri, Rakesh M; Dearani, Joseph A; Topilsky, Yan; Stulak, John M; Joyce, Lyle D; Park, Soon J

    2014-04-01

    Patients with severe ischemic cardiomyopathy (left ventricular ejection fraction <25%) and severe ischemic mitral regurgitation have a poor survival with medical therapy alone. Left ventricular assist device as destination therapy is reserved for patients who are too high risk for conventional surgery. We evaluated our outcomes with conventional surgery within this population and the comparative effectiveness of these 2 therapies. We identified patients who underwent conventional surgery or left ventricular assist device as destination therapy for severe ischemic cardiomyopathy (left ventricular ejection fraction <25%) and severe mitral regurgitation. The era for conventional surgery spanned from 1993 to 2009 and from 2007 to 2011 for left ventricular assist device as destination therapy. We compared baseline patient characteristics and outcomes in terms of end-organ function and survival. A total of 88 patients were identified; 55 patients underwent conventional surgery (63%), and 33 patients (37%) received a left ventricular assist device as destination therapy. Patients who received left ventricular assist device as destination therapy had the increased prevalence of renal failure, inotrope dependency, and intra-aortic balloon support. Patients undergoing conventional surgery required longer ventilatory support, and patients receiving a left ventricular assist device required more reoperation for bleeding. Mortality rates were similar between the 2 groups at 30 days (7% in the conventional surgery group vs 3% in the left ventricular assist device as destination therapy group, P = .65) and at 1 year (22% in the conventional surgery group vs 15% in the left ventricular assist device as destination therapy group, P = .58). There was a trend toward improved survival in patients receiving a left ventricular assist device compared with the propensity-matched groups at 1 year (94% vs 71%, P = .171). The operative mortality and early survival after conventional surgery seem to be acceptable. For inoperable or prohibitive-risk patients, left ventricular assist device as destination therapy can be offered with similar outcomes. Copyright © 2014 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  7. Surgery for endometriosis-associated infertility: do we exaggerate the magnitude of effect?

    PubMed

    Rizk, B; Turki, R; Lotfy, H; Ranganathan, S; Zahed, H; Freeman, A R; Shilbayeh, Z; Sassy, M; Shalaby, M; Malik, R

    2015-01-01

    Surgery remains the mainstay in the diagnosis and management of endometriosis. The number of surgeries performed for endometriosis worldwide is ever increasing, however do we have evidence for improvement of infertility after the surgery and do we exaggerate the magnitude of effect of surgery when we counsel our patients? The management of patients who failed the surgery could be by repeat surgery or assisted reproduction. What evidence do we have for patients who fail assisted reproduction and what is their best chance for achieving pregnancy? In this study we reviewed the evidence-based practice pertaining to the outcome of surgery assisted infertility associated with endometriosis. Manuscripts published in PubMed and Science Direct as well as the bibliography cited in these articles were reviewed. Patients with peritoneal endometriosis with mild and severe disease were addressed separately. Patients who failed the primary surgery and managed by repeat or assisted reproduction technology were also evaluated. Patients who failed assisted reproduction and managed by surgery were also studied to determine of the best course of action. In patients with minimal and mild pelvic endometriosis, excision or ablation of the peritoneal endometriosis increases the pregnancy rate. In women with severe endometriosis, controlled trials suggested an improvement of pregnancy rate. In women with ovarian endometrioma 4 cm or larger ovarian cystectomy increases the pregnancy rate, decreases the recurrence rate, but is associated with decrease in ovarian reserve. In patients who have failed the primary surgery, assisted reproduction appears to be significantly more effective than repeat surgery. In patients who failed assisted reproduction, the management remains to be extremely controversial. Surgery in expert hands might result in significant improvement in pregnancy rate. In women with minimal and mild endometriosis, surgical excision or ablation of endometriosis is recommended as first line with doubling the pregnancy rate. In patients with moderate and severe endometriosis surgical excision also is recommended as first line. In patients who failed to conceive spontaneously after surgery, assisted reproduction is more effective than repeat surgery. Following surgery, the ovarian reserve may be reduced as determined by Anti Mullerian Hormone. The antral follicle count is not significantly reduced. In women with large endometriomas > 4 cm the ovarian endometrioma should be removed. In women who have failed assisted reproduction, further management remains controversial in the present time.

  8. [Navigated control: a new concept in computer assisted ENT-surgery].

    PubMed

    Strauss, G; Koulechov, K; Richter, R; Dietz, A; Meixensberger, J; Trantakis, C; Lüth, T

    2005-08-01

    This work conceived and evaluates a mechatronical system for ORL-surgery by example of a Shaver for Functional Endoscopic Sinus Surgery controlled by navigation. The Shaver is automatically on/off-regulated depending on the current position in relation to the planned working space. This working space is defined on the basis of the individual CT data. Within this area the Shaver reacts to the signal of the surgeon (foot pedal). If the Shaver leaves the working space, an interruption of the drive regulation to the Shaver takes place. The evaluation of the planning software based on 32 patient CT-data sets. The registration accuracy in a anatomical model was examined on 451 measurements of endonasal attached titanium screws. The conversions of the working space were evaluated at 5 different technical models. The average time for segmenting the working space was found at 4.23 minutes per case. An average registration accuracy of the Shaver of 1.08 mm resulted. The pre-defined cavity was to be cleared away without restrictions. The preoperative determined work-space was converted by 3.1 mm over all levels. The study proves the feasibility of a mechatronical assistant system by the example of the navigate-controlled Shaver in paranasal sinus surgery. Contrary to conventional CAS solutions redundancy and cognitive discharge of the surgeon are considered in this conception. We see numerous applications according to the explained principle for power-control of instruments in ORL-surgery in the future such as drilling, high frequency surgery or laser.

  9. Robotic surgery for colorectal cancer: systematic review of the literature.

    PubMed

    Papanikolaou, Ioannis G

    2014-12-01

    Surgical practice has been changed since the introduction of robotic techniques and robotic colorectal surgery is an emerging field. Innovative robotic technologies have helped surgeons overcome many technical difficulties of conventional laparoscopic surgery. Herein, we review the clinical studies regarding the application of surgical robots in resections for colorectal cancer. A systematic review of the literature was conducted for articles published up to September 9, 2012, using the MEDLINE database. The keywords that were used in various combinations were: "surgical robotics," "robotic surgery," "computer-assisted surgery," "colectomy," "sigmoid resection," "sigmoidectomy," and "rectal resection." Fifty-nine articles reporting on robot-assisted resections of colon and/or rectum were identified and 41 studies were finally included in the analysis. A total of 1635 colorectal procedures were performed: 254 right colectomies, 185 left colectomies/sigmoid resections, 969 anterior resections, 182 abdominoperineal or intersphincteric resections, 34 colectomies (without being specified as right or left), and 11 total/subtotal colectomies. In general, blood loss, conversion rates, and complications were low but the operative time was longer than the open procedures, whereas the duration of hospitalization was shorter. The number of harvested lymph nodes was also quite satisfactory. Robotic colorectal operations provide favorable results, with acceptable operative times and low conversion rates and morbidity. Surgical robots may provide additional benefits treating challenging pathologies, such as rectal cancer. Further clinical studies and long-term follow-up are required to better evaluate the outcomes of robotic colorectal surgery.

  10. Computer-assisted versus conventional free fibula flap technique for craniofacial reconstruction: an outcomes comparison.

    PubMed

    Seruya, Mitchel; Fisher, Mark; Rodriguez, Eduardo D

    2013-11-01

    There has been rising interest in computer-aided design/computer-aided manufacturing for preoperative planning and execution of osseous free flap reconstruction. The purpose of this study was to compare outcomes between computer-assisted and conventional fibula free flap techniques for craniofacial reconstruction. A two-center, retrospective review was carried out on patients who underwent fibula free flap surgery for craniofacial reconstruction from 2003 to 2012. Patients were categorized by the type of reconstructive technique: conventional (between 2003 and 2009) or computer-aided design/computer-aided manufacturing (from 2010 to 2012). Demographics, surgical factors, and perioperative and long-term outcomes were compared. A total of 68 patients underwent microsurgical craniofacial reconstruction: 58 conventional and 10 computer-aided design and manufacturing fibula free flaps. By demographics, patients undergoing the computer-aided design/computer-aided manufacturing method were significantly older and had a higher rate of radiotherapy exposure compared with conventional patients. Intraoperatively, the median number of osteotomies was significantly higher (2.0 versus 1.0, p=0.002) and the median ischemia time was significantly shorter (120 minutes versus 170 minutes, p=0.004) for the computer-aided design/computer-aided manufacturing technique compared with conventional techniques; operative times were shorter for patients undergoing the computer-aided design/computer-aided manufacturing technique, although this did not reach statistical significance. Perioperative and long-term outcomes were equivalent for the two groups, notably, hospital length of stay, recipient-site infection, partial and total flap loss, and rate of soft-tissue and bony tissue revisions. Microsurgical craniofacial reconstruction using a computer-assisted fibula flap technique yielded significantly shorter ischemia times amidst a higher number of osteotomies compared with conventional techniques. Therapeutic, III.

  11. The expert surgical assistant. An intelligent virtual environment with multimodal input.

    PubMed

    Billinghurst, M; Savage, J; Oppenheimer, P; Edmond, C

    1996-01-01

    Virtual Reality has made computer interfaces more intuitive but not more intelligent. This paper shows how an expert system can be coupled with multimodal input in a virtual environment to provide an intelligent simulation tool or surgical assistant. This is accomplished in three steps. First, voice and gestural input is interpreted and represented in a common semantic form. Second, a rule-based expert system is used to infer context and user actions from this semantic representation. Finally, the inferred user actions are matched against steps in a surgical procedure to monitor the user's progress and provide automatic feedback. In addition, the system can respond immediately to multimodal commands for navigational assistance and/or identification of critical anatomical structures. To show how these methods are used we present a prototype sinus surgery interface. The approach described here may easily be extended to a wide variety of medical and non-medical training applications by making simple changes to the expert system database and virtual environment models. Successful implementation of an expert system in both simulated and real surgery has enormous potential for the surgeon both in training and clinical practice.

  12. "Ipsilateral, high, single-hand, sideways"-Ruijin rule for camera assistant in uniportal video-assisted thoracoscopic surgery.

    PubMed

    Gao, Taotao; Xiang, Jie; Jin, Runsen; Zhang, Yajie; Wu, Han; Li, Hecheng

    2016-10-01

    Camera assistant plays a very important role in uniportal video-assisted thoracoscopic surgery (VATS), who acts as the eye of the surgeon, providing the VATS team with a stable and clear operating view. Thus, a good assistant should cooperate with surgeon and manipulate the camera expertly, to ensure eye-hand coordination. We have performed more than 100 uniportal VATS in the Department Of Thoracic Surgery in Ruijin Hospital. Based on our experiences, we summarized the method of holding camera, known as "ipsilateral, high, single-hand, sideways", which largely improves the comfort and fluency of surgery.

  13. Measurement of breast volume using body scan technology(computer-aided anthropometry).

    PubMed

    Veitch, Daisy; Burford, Karen; Dench, Phil; Dean, Nicola; Griffin, Philip

    2012-01-01

    Assessment of breast volume is an important tool for preoperative planning in various breast surgeries and other applications, such as bra development. Accurate assessment can improve the consistency and quality of surgery outcomes. This study outlines a non-invasive method to measure breast volume using a whole body 3D laser surface anatomy scanner, the Cyberware WBX. It expands on a previous publication where this method was validated against patients undergoing mastectomy. It specifically outlines and expands the computer-aided anthropometric (CAA) method for extracting breast volumes in a non-invasive way from patients enrolled in a breast reduction study at Flinders Medical Centre, South Australia. This step-by-step description allows others to replicate this work and provides an additional tool to assist them in their own clinical practice and development of designs.

  14. Patient-specific reconstruction plates are the missing link in computer-assisted mandibular reconstruction: A showcase for technical description.

    PubMed

    Cornelius, Carl-Peter; Smolka, Wenko; Giessler, Goetz A; Wilde, Frank; Probst, Florian A

    2015-06-01

    Preoperative planning of mandibular reconstruction has moved from mechanical simulation by dental model casts or stereolithographic models into an almost completely virtual environment. CAD/CAM applications allow a high level of accuracy by providing a custom template-assisted contouring approach for bone flaps. However, the clinical accuracy of CAD reconstruction is limited by the use of prebent reconstruction plates, an analogue step in an otherwise digital workstream. In this paper the integration of computerized, numerically-controlled (CNC) milled, patient-specific mandibular plates (PSMP) within the virtual workflow of computer-assisted mandibular free fibula flap reconstruction is illustrated in a clinical case. Intraoperatively, the bone segments as well as the plate arms showed a very good fit. Postoperative CT imaging demonstrated close approximation of the PSMP and fibular segments, and good alignment of native mandible and fibular segments and intersegmentally. Over a follow-up period of 12 months, there was an uneventful course of healing with good bony consolidation. The virtual design and automated fabrication of patient-specific mandibular reconstruction plates provide the missing link in the virtual workflow of computer-assisted mandibular free fibula flap reconstruction. Copyright © 2015 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  15. Incorporating robotic-assisted surgery for endometrial cancer staging: Analysis of morbidity and costs.

    PubMed

    Bogani, Giorgio; Multinu, Francesco; Dowdy, Sean C; Cliby, William A; Wilson, Timothy O; Gostout, Bobbie S; Weaver, Amy L; Borah, Bijan J; Killian, Jill M; Bijlani, Akash; Angioni, Stefano; Mariani, Andrea

    2016-05-01

    To evaluate how the introduction of robotic-assisted surgery affects treatment-related morbidity and cost of endometrial cancer (EC) staging. We retrospectively reviewed the records of consecutive patients with stage I-III EC undergoing surgical staging between 2007 and 2012 at our institution. Costs (from surgery to 30days after surgery) were set based on the Medicare cost-to-charge ratio for each year and inflated to 2014 values. Inverse probability weighting (IPW) was used to decrease the allocation bias when comparing outcomes between surgical groups. We focused our analysis on the 251 EC patients who had robotic-assisted surgery and the 384 who had open staging. During the study period, the use of robotic-assisted surgery increased and open staging decreased (P<0.001). Correcting group imbalances by using IPW methodology, we observed that patients undergoing robotic-assisted staging had a significantly lower postoperative complication rate, lower blood transfusion rate, longer median operating time, shorter median length of stay, and lower readmission rate than patients undergoing open staging (all P<0.001). Overall 30-day costs were similar between the 2 groups, with robotic-assisted surgery having significantly higher median operating room costs ($2820 difference; P<0.001) but lower median room and board costs ($2929 difference; P<0.001) than open surgery. Increasing experience with robotic-assisted staging was significantly associated with a decrease in median operating time (P=0.002) and length of stay (P=0.003). The implementation of robotic-assisted surgery for EC staging improves patient outcomes. It provides women the benefits of minimally invasive surgery without increasing costs and potentially improves patient turnover. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. Image-guided techniques in renal and hepatic interventions.

    PubMed

    Najmaei, Nima; Mostafavi, Kamal; Shahbazi, Sahar; Azizian, Mahdi

    2013-12-01

    Development of new imaging technologies and advances in computing power have enabled the physicians to perform medical interventions on the basis of high-quality 3D and/or 4D visualization of the patient's organs. Preoperative imaging has been used for planning the surgery, whereas intraoperative imaging has been widely employed to provide visual feedback to a clinician when he or she is performing the procedure. In the past decade, such systems demonstrated great potential in image-guided minimally invasive procedures on different organs, such as brain, heart, liver and kidneys. This article focuses on image-guided interventions and surgery in renal and hepatic surgeries. A comprehensive search of existing electronic databases was completed for the period of 2000-2011. Each contribution was assessed by the authors for relevance and inclusion. The contributions were categorized on the basis of the type of operation/intervention, imaging modality and specific techniques such as image fusion and augmented reality, and organ motion tracking. As a result, detailed classification and comparative study of various contributions in image-guided renal and hepatic interventions are provided. In addition, the potential future directions have been sketched. With a detailed review of the literature, potential future trends in development of image-guided abdominal interventions are identified, namely, growing use of image fusion and augmented reality, computer-assisted and/or robot-assisted interventions, development of more accurate registration and navigation techniques, and growing applications of intraoperative magnetic resonance imaging. Copyright © 2012 John Wiley & Sons, Ltd.

  17. Cosmetic and aesthetic skin photosurgery using a computer-assisted CO2 laser-scanning system

    NASA Astrophysics Data System (ADS)

    Dutu, Doru C. A.; Dumitras, Dan C.; Nedelcu, Ioan; Ghetie, Sergiu D.

    1997-12-01

    Since the first application of CO2 laser in skin photosurgery, various techniques such as laser pulsing, beam scanning and computer-assisted laser pulse generator have been introduced for the purpose of reducing tissue carbonization and thermal necrosis. Using a quite simple XY optical scanner equipped with two galvanometric driven mirrors and an appropriate software to process the scanning data and control the interaction time and energy density in the scanned area, we have obtained a device which can improve CO2 laser application in cosmetic and aesthetic surgery. The opto-mechanical CO2 laser scanner based on two total reflecting flat mirrors placed at 90 degree(s) in respect to the XY scanning directions and independently driven through a magnetic field provides a linear movement of the incident laser beam in the operating field. A DA converter supplied with scanning data by the software enables a scanning with linearity better than 1% for a maximum angular deviation of 20 degree(s). Because the scanning quality of the laser beam in the operating field is given not only by the displacement function of the two mirrors, but also by the beam characteristics in the focal plane and the cross distribution in the laser beam, the surgeon can control through software either the scanning field dimensions or the distance between two consecutive points of the vertically and/or horizontally sweep line. The development of computer-assisted surgical scanning techniques will help control the surgical laser, to create either a reproducible incision with a controlled depth or a controlled incision pattern with minimal incision width, a long desired facility for plastic surgery, neurosurgery, ENT and dentistry.

  18. Computer-assisted virtual preoperative planning in orthopedic surgery for acetabular fractures based on actual computed tomography data.

    PubMed

    Wang, Guang-Ye; Huang, Wen-Jun; Song, Qi; Qin, Yun-Tian; Liang, Jin-Feng

    2016-12-01

    Acetabular fractures have always been very challenging for orthopedic surgeons; therefore, appropriate preoperative evaluation and planning are particularly important. This study aimed to explore the application methods and clinical value of preoperative computer simulation (PCS) in treating pelvic and acetabular fractures. Spiral computed tomography (CT) was performed on 13 patients with pelvic and acetabular fractures, and Digital Imaging and Communications in Medicine (DICOM) data were then input into Mimics software to reconstruct three-dimensional (3D) models of actual pelvic and acetabular fractures for preoperative simulative reduction and fixation, and to simulate each surgical procedure. The times needed for virtual surgical modeling and reduction and fixation were also recorded. The average fracture-modeling time was 45 min (30-70 min), and the average time for bone reduction and fixation was 28 min (16-45 min). Among the surgical approaches planned for these 13 patients, 12 were finally adopted; 12 cases used the simulated surgical fixation, and only 1 case used a partial planned fixation method. PCS can provide accurate surgical plans and data support for actual surgeries.

  19. Thoracoscopic sympathicotomy in the treatment of palmar hyperhidrosis.

    PubMed

    Bagheri, Reza; Sharifian Attar, Alireza; Haghi, Seyed Ziaollah; Salehi, Maryam; Moradpoor, Rosita

    2016-09-01

    Primary hyperhidrosis interferes with social activities and requires an effective and safe treatment. We aimed to compare the therapeutic outcomes of unilateral single-port sympathicotomy and open surgery. Forty patients with primary palmar hyperhidrosis underwent sympathicotomy; 20 had open surgery, and 20 had video-assisted thoracic surgery. Complete resection of the T1 to T4 ganglia was performed by open surgery, and cutting and cauterization of the sympathetic chain between the T2 and T3 ganglia in the dominant hand was undertaken using video-assisted thoracic surgery. The patients were followed up at 1, 3, 6, and 12 months after surgery. The mean operative times were 39.6 ± 1.46 and 79.8 ± 1.53 min in the video-assisted thoracic surgery and open surgery group, respectively. The mean hospitalization was 2.2 ± 0.41 days after video-assisted thoracic surgery and 3.3 ± 0.47 days after open surgery. Complications included delayed hemothorax, compensatory hyperhidrosis, and wound infection. The mean blood loss during surgery and time to return to work were significantly less in the video-assisted thoracic surgery group. Excessive sweating was completely alleviated in the dominant hand in all patients, and in the opposite hand in 60% and 65% of the video-assisted thoracic surgery and open surgery group, respectively. Single-port sympathicotomy between the T2 and T3 ganglia ipsilateral to the dominant hand is a safe, minimally invasive, and effective treatment for primary palmar hyperhidrosis. Alleviation of excessive sweating in the opposite hand can also be achieved in a large proportion of these patients. © The Author(s) 2016.

  20. Effect of Regional Hospital Competition and Hospital Financial Status on the Use of Robotic-Assisted Surgery.

    PubMed

    Wright, Jason D; Tergas, Ana I; Hou, June Y; Burke, William M; Chen, Ling; Hu, Jim C; Neugut, Alfred I; Ananth, Cande V; Hershman, Dawn L

    2016-07-01

    Despite the lack of efficacy data, robotic-assisted surgery has diffused rapidly into practice. Marketing to physicians, hospitals, and patients has been widespread, but how this marketing has contributed to the diffusion of the technology remains unknown. To examine the effect of regional hospital competition and hospital financial status on the use of robotic-assisted surgery for 5 commonly performed procedures. A cohort study of 221 637 patients who underwent radical prostatectomy, total nephrectomy, partial nephrectomy, hysterectomy, or oophorectomy at 1370 hospitals in the United States from January 1, 2010, to December 31, 2011, was conducted. The association between hospital competition, hospital financial status, and performance of robotic-assisted surgery was examined. The association between hospital competition was measured with the Herfindahl-Hirschman Index (HHI), hospital financial status was estimated as operating margin, and performance of robotic-assisted surgery was examined using multivariate mixed-effects regression models. We identified 221 637 patients who underwent one of the procedures of interest. The cohort included 30 345 patients who underwent radical prostatectomy; 20 802, total nephrectomy; 8060, partial nephrectomy; 134 985, hysterectomy; and 27 445, oophorectomy. Robotic-assisted operations were performed for 20 500 (67.6%) radical prostatectomies, 1405 (6.8%) total nephrectomies, 2759 (34.2%) partial nephrectomies, 14 047 (10.4%) hysterectomies, and 1782 (6.5%) oophorectomies. Use of robotic-assisted surgery increased for each procedure from January 2010 through December 2011. For all 5 operations, increased market competition (as measured by the HHI) was associated with increased use of robotic-assisted surgery. For prostatectomy, the risk ratios (95% CIs) for undergoing a robotic-assisted procedure were 2.20 (1.50-3.24) at hospitals in moderately competitive markets and 2.64 (1.84-3.78) for highly competitive markets compared with noncompetitive markets. For hysterectomy, patients at hospitals in moderately (3.75 [2.26-6.25]) and highly (5.30; [3.27-8.57]) competitive markets were more likely to undergo a robotic-assisted surgery. Increased hospital profitability was associated with use of robotic-assisted surgery only for partial nephrectomy in facilities with medium-high (1.67 [1.13-2.48]) and high (1.50 [0.98-2.29]) operating margins. With analysis limited to patients treated at a hospital that had performed robotic-assisted surgery, there was no longer an association between competition and use of robotic-assisted surgery. Patients undergoing surgery in a hospital in a competitive regional market were more likely to undergo a robotic-assisted procedure. These data imply that regional competition may influence a hospital's decision to acquire a surgical robot.

  1. Routine history as compared to audio computer-assisted self-interview for prenatal care history taking.

    PubMed

    Mears, Molly; Coonrod, Dean V; Bay, R Curtis; Mills, Terry E; Watkins, Michelle C

    2005-09-01

    To compare endorsement rates obtained with audio computer-assisted self-interview versus routine prenatal history. A crosssectional study compared items captured with the routine history to those captured with a computer interview (computer screen displaying and computer audio reading questions, with responses entered by touch screen). The subjects were women (n=174) presenting to a public hospital clinic for prenatal care. The prevalence of positive responses using the computer interview was significantly greater (p < 0.01) than with the routine history for induced abortion (16.8% versus 4.0%), lifetime smoking (12.8% versus 5.2%), intimate partner violence (10.0% versus 2.4%), ectopic pregnancy (5.2% versus 1.1%) and family history of mental retardation (6.7% versus 0.6%). Significant differences were not found for history of spontaneous abortion, hypertension, epilepsy, thyroid disease, smoking during pregnancy, gynecologic surgery, abnormal Pap test, neural tube defect or cystic fibrosis family history. However, in all cases, prevalence was equal or greater with the computer interview. Women were more likely to report sensitive and high-risk behavior, such as smoking history, intimate partner violence and elective abortion, with the computer interview. The computer interview displayed equal or increased patient reporting of positive responses and may therefore be an accurate method of obtaining an initial history.

  2. Anesthetic Considerations in Robotic-Assisted Gynecologic Surgery

    PubMed Central

    Kaye, Alan D.; Vadivelu, Nalini; Ahuja, Nitin; Mitra, Sukanya; Silasi, Dan; Urman, Richard D.

    2013-01-01

    Background Robotic-assisted surgery has evolved over the past 2 decades with constantly improving technology that assists surgeons in multiple subspecialty disciplines. The surgical requirements of lithotomy and steep Trendelenburg positions, along with the creation of a pneumoperitoneum and lack of direct access to the patient all present management challenges in gynecologic surgery. Patient positioning requirements can have significant physiologic effects and can result in many complications. Methods This review focuses on the anesthetic and surgical implications of robot-assisted technology in gynecologic surgery. Conclusion Good communication among team members and knowledge of the nuances of robotic surgery have the potential to improve patient outcomes, increase efficiency, and reduce complications. PMID:24358000

  3. Technical features of the robot-assisted trans-axillary thyroidectomy.

    PubMed

    Axente, D D; Major, Z Z; Micu, C M; Constantea, N A

    2013-01-01

    Numerous minimally invasive techniques for thyroid surgery have been described in recent years. Technical disadvantages have led to low practicability, although these techniques proved to be safe and to deliver good results. The robotic system was developed to overcome the limits of endoscopic surgery.Recently, based on the advantages of this new technology, robot assisted endoscopic surgery was introduced for minimally invasive thyroid surgery as well. Our experience with robot-assisted transaxillary thyroid surgery begins in November 2010 when we have practiced our first unilateral total lobectomy. From November 2010 to March 2012, 50 patients underwent robot assisted endoscopic thyroid surgery using the transaxillary approach. The aim of this study is to present the technical details and particularities of this procedure, based on our experience.

  4. Robot-assisted Versus Laparoscopic Surgery for Rectal Cancer: A Phase II Open Label Prospective Randomized Controlled Trial.

    PubMed

    Kim, Min Jung; Park, Sung Chan; Park, Ji Won; Chang, Hee Jin; Kim, Dae Yong; Nam, Byung-Ho; Sohn, Dae Kyung; Oh, Jae Hwan

    2018-02-01

    The phase II randomized controlled trial aimed to compare the outcomes of robot-assisted surgery with those of laparoscopic surgery in the patients with rectal cancer. The feasibility of robot-assisted surgery over laparoscopic surgery for rectal cancer has not been established yet. Between February 21, 2012 and March 11, 2015, patients with rectal cancer (cT1-3NxM0) were enrolled. Patients were randomized 1:1 to either robot-assisted or laparoscopic surgery, and stratified per sex and administration of preoperative chemoradiotherapy. The primary outcome was the quality of total mesorectal excision (TME) specimen. Secondary outcomes were the circumferential and distal resection margins, the number of harvested lymph nodes, morbidity, bowel function recovery, and quality of life. A total of 163 patients were randomly assigned to the robot-assisted (n = 81) and laparoscopic (n = 82) surgery groups, and 139 patients were eligible for the analyses (73 vs 66, respectively). One patient (1.2%) in the robot-assisted group was converted to open surgery. The TME quality did not differ between the robot-assisted and laparoscopic groups (80.3% vs 78.1% complete TME, respectively; 18.2% vs 21.9% nearly complete TME, respectively; P = 0.599). The resection margins, number of harvested lymph nodes, morbidity, and bowel function recovery also were not significantly different. On analyzing quality of life, scores of the European Organization for Research and Treatment of Cancer Quality of Life (EORTC QLQ C30) and EORTC QLQ CR38 were similar in the 2 groups, but in the EORTC QLQ CR 38 questionnaire, sexual function 12 months postoperatively was better in the robot-assisted group than in the laparoscopic group (P = 0.03). Robot-assisted surgery in rectal cancer showed TME quality comparable with that of laparoscopic surgery, and it demonstrated similar postoperative morbidity, bowel function recovery, and quality of life.

  5. “Ipsilateral, high, single-hand, sideways”—Ruijin rule for camera assistant in uniportal video-assisted thoracoscopic surgery

    PubMed Central

    Gao, Taotao; Xiang, Jie; Jin, Runsen; Zhang, Yajie; Wu, Han

    2016-01-01

    Camera assistant plays a very important role in uniportal video-assisted thoracoscopic surgery (VATS), who acts as the eye of the surgeon, providing the VATS team with a stable and clear operating view. Thus, a good assistant should cooperate with surgeon and manipulate the camera expertly, to ensure eye-hand coordination. We have performed more than 100 uniportal VATS in the Department Of Thoracic Surgery in Ruijin Hospital. Based on our experiences, we summarized the method of holding camera, known as “ipsilateral, high, single-hand, sideways”, which largely improves the comfort and fluency of surgery. PMID:27867573

  6. Economic evaluation comparing intraoperative cone beam CT-based navigation and conventional fluoroscopy for the placement of spinal pedicle screws: a patient-level data cost-effectiveness analysis.

    PubMed

    Dea, Nicolas; Fisher, Charles G; Batke, Juliet; Strelzow, Jason; Mendelsohn, Daniel; Paquette, Scott J; Kwon, Brian K; Boyd, Michael D; Dvorak, Marcel F S; Street, John T

    2016-01-01

    Pedicle screws are routinely used in contemporary spinal surgery. Screw misplacement may be asymptomatic but is also correlated with potential adverse events. Computer-assisted surgery (CAS) has been associated with improved screw placement accuracy rates. However, this technology has substantial acquisition and maintenance costs. Despite its increasing usage, no rigorous full economic evaluation comparing this technology to current standard of care has been reported. Medical costs are exploding in an unsustainable way. Health economic theory requires that medical equipment costs be compared with expected benefits. To answer this question for computer-assisted spinal surgery, we present an economic evaluation looking specifically at symptomatic misplaced screws leading to reoperation secondary to neurologic deficits or biomechanical concerns. The study design was an observational case-control study from prospectively collected data of consecutive patients treated with the aid of CAS (treatment group) compared with a matched historical cohort of patients treated with conventional fluoroscopy (control group). The patient sample consisted of consecutive patients treated surgically at a quaternary academic center. The primary effectiveness measure studied was the number of reoperations for misplaced screws within 1 year of the index surgery. Secondary outcome measures included were total adverse event rate and postoperative computed tomography usage for pedicle screw examination. A patient-level data cost-effectiveness analysis from the hospital perspective was conducted to determine the value of a navigation system coupled with intraoperative 3-D imaging (O-arm Imaging and the StealthStation S7 Navigation Systems, Medtronic, Louisville, CO, USA) in adult spinal surgery. The capital costs for both alternatives were reported as equivalent annual costs based on the annuitization of capital expenditures method using a 3% discount rate and a 7-year amortization period. Annual maintenance costs were also added. Finally, reoperation costs using a micro-costing approach were calculated for both groups. An incremental cost-effectiveness ratio was calculated and reported as cost per reoperation avoided. Based on reoperation costs in Canada and in the United States, a minimal caseload was calculated for the more expensive alternative to be cost saving. Sensitivity analyses were also conducted. A total of 5,132 pedicle screws were inserted in 502 patients during the study period: 2,682 screws in 253 patients in the treatment group and 2,450 screws in 249 patients in the control group. Overall accuracy rates were 95.2% for the treatment group and 86.9% for the control group. Within 1 year post treatment, two patients (0.8%) required a revision surgery in the treatment group compared with 15 patients (6%) in the control group. An incremental cost-effectiveness ratio of $15,961 per reoperation avoided was calculated for the CAS group. Based on a reoperation cost of $12,618, this new technology becomes cost saving for centers performing more than 254 instrumented spinal procedures per year. Computer-assisted spinal surgery has the potential to reduce reoperation rates and thus to have serious cost-effectiveness and policy implications. High acquisition and maintenance costs of this technology can be offset by equally high reoperation costs. Our cost-effectiveness analysis showed that for high-volume centers with a similar case complexity to the studied population, this technology is economically justified. Copyright © 2015 Elsevier Inc. All rights reserved.

  7. The use of computer-assisted orthopedic surgery for total knee replacement in daily practice: a survey among ESSKA/SGO-SSO members.

    PubMed

    Friederich, N; Verdonk, R

    2008-06-01

    Computer-assisted orthopedic surgery (CAOS) for total knee arthroplasty is an emerging surgical tool, yet little is known about how it is being used in everyday orthopedic centers. We sought to better understand physicians' current practices and beliefs on this topic through performing a Web-based survey. Between December 2006 and January 2007, a 24-question survey was emailed to 3,330 members of the European Society of Sports Traumatology Knee Surgery and Arthroscopy (ESSKA) and the Swiss Orthopedic Society (SGO-SSO), with 389 (11.7%) agreeing to participate. Of this group, 202 (51.9%) reported that their center was equipped with a navigation system, which was an image-free based system for most (83.2%) and was primarily used for total knee arthroplasty (61.4%). In terms of the proportion of use, 50.5% of respondents used their navigation system in less than 25% of cases, 16.3% in 25-50% of cases, 7.4% in 51-75% of cases, and 25.7% in more than 75% of cases. The potential for improving the alignment of prosthesis was the most strongly cited reason for using a navigation system, while the potential for increasing operation times and the risk of infections were the most strongly cited reasons for not using a navigation system. Approximately half of respondents surveyed believed navigation systems were a real innovation contributing to the improvement of total knee implantation. However, heavy usage of computer-assisted navigation (> or =51% of cases) was observed in only 33.1% of respondents, with only a quarter using it at rates that could be considered frequent (>75% of cases). Forty-eight percent of respondents said they will use a navigation system in more cases and 39.1% that their usage will stay the same. These findings indicate that CAOS is being used only moderately in current practices, though respondents generally had a positive opinion of its potential benefits. Physicians may be awaiting more data before adopting the use of these systems, though survey responses also suggest a projected increase in their use in the coming years.

  8. Splint sterilization--a potential registration hazard in computer-assisted surgery.

    PubMed

    Figl, Michael; Weber, Christoph; Assadian, Ojan; Toma, Cyril D; Traxler, Hannes; Seemann, Rudolf; Guevara-Rojas, Godoberto; Pöschl, Wolfgang P; Ewers, Rolf; Schicho, Kurt

    2012-04-01

    Registration of preoperative targeting information for the intraoperative situation is a crucial step in computer-assisted surgical interventions. Point-to-point registration using acrylic splints is among the most frequently used procedures. There are, however, no generally accepted recommendations for sterilization of the splint. An appropriate method for the thermolabile splint would be hydrogen peroxide-based plasma sterilization. This study evaluated the potential deformation of the splint undergoing such sterilization. Deformation was quantified using image-processing methods applied to computed tomographic (CT) volumes before and after sterilization. An acrylic navigation splint was used as the study object. Eight metallic markers placed in the splint were used for registration. Six steel spheres in the mouthpiece were used as targets. Two CT volumes of the splint were acquired before and after 5 sterilization cycles using a hydrogen peroxide sterilizer. Point-to-point registration was applied, and fiducial and target registration errors were computed. Surfaces were extracted from CT scans and Hausdorff distances were derived. Effectiveness of sterilization was determined using Geobacillus stearothermophilus. Fiducial-based registration of CT scans before and after sterilization resulted in a mean fiducial registration error of 0.74 mm; the target registration error in the mouthpiece was 0.15 mm. The Hausdorff distance, describing the maximal deformation of the splint, was 2.51 mm. Ninety percent of point-surface distances were shorter than 0.61 mm, and 95% were shorter than 0.73 mm. No bacterial growth was found after the sterilization process. Hydrogen peroxide-based low-temperature plasma sterilization does not deform the splint, which is the base for correct computer-navigated surgery. Copyright © 2012 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  9. Three-dimensional virtual planning in orthognathic surgery enhances the accuracy of soft tissue prediction.

    PubMed

    Van Hemelen, Geert; Van Genechten, Maarten; Renier, Lieven; Desmedt, Maria; Verbruggen, Elric; Nadjmi, Nasser

    2015-07-01

    Throughout the history of computing, shortening the gap between the physical and digital world behind the screen has always been strived for. Recent advances in three-dimensional (3D) virtual surgery programs have reduced this gap significantly. Although 3D assisted surgery is now widely available for orthognathic surgery, one might still argue whether a 3D virtual planning approach is a better alternative to a conventional two-dimensional (2D) planning technique. The purpose of this study was to compare the accuracy of a traditional 2D technique and a 3D computer-aided prediction method. A double blind randomised prospective study was performed to compare the prediction accuracy of a traditional 2D planning technique versus a 3D computer-aided planning approach. The accuracy of the hard and soft tissue profile predictions using both planning methods was investigated. There was a statistically significant difference between 2D and 3D soft tissue planning (p < 0.05). The statistically significant difference found between 2D and 3D planning and the actual soft tissue outcome was not confirmed by a statistically significant difference between methods. The 3D planning approach provides more accurate soft tissue planning. However, the 2D orthognathic planning is comparable to 3D planning when it comes to hard tissue planning. This study provides relevant results for choosing between 3D and 2D planning in clinical practice. Copyright © 2015 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  10. Homographic Patch Feature Transform: A Robustness Registration for Gastroscopic Surgery.

    PubMed

    Hu, Weiling; Zhang, Xu; Wang, Bin; Liu, Jiquan; Duan, Huilong; Dai, Ning; Si, Jianmin

    2016-01-01

    Image registration is a key component of computer assistance in image guided surgery, and it is a challenging topic in endoscopic environments. In this study, we present a method for image registration named Homographic Patch Feature Transform (HPFT) to match gastroscopic images. HPFT can be used for tracking lesions and augmenting reality applications during gastroscopy. Furthermore, an overall evaluation scheme is proposed to validate the precision, robustness and uniformity of the registration results, which provides a standard for rejection of false matching pairs from corresponding results. Finally, HPFT is applied for processing in vivo gastroscopic data. The experimental results show that HPFT has stable performance in gastroscopic applications.

  11. Minimally invasive and computer-navigated total hip arthroplasty: a qualitative and systematic review of the literature

    PubMed Central

    2010-01-01

    Background Both minimally invasive surgery (MIS) and computer-assisted surgery (CAS) for total hip arthroplasty (THA) have gained popularity in recent years. We conducted a qualitative and systematic review to assess the effectiveness of MIS, CAS and computer-assisted MIS for THA. Methods An extensive computerised literature search of PubMed, Medline, Embase and OVIDSP was conducted. Both randomised clinical trials and controlled clinical trials on the effectiveness of MIS, CAS and computer-assisted MIS for THA were included. Methodological quality was independently assessed by two reviewers. Effect estimates were calculated and a best-evidence synthesis was performed. Results Four high-quality and 14 medium-quality studies with MIS THA as study contrast, and three high-quality and four medium-quality studies with CAS THA as study contrast were included. No studies with computer-assisted MIS for THA as study contrast were identified. Strong evidence was found for a decrease in operative time and intraoperative blood loss for MIS THA, with no difference in complication rates and risk for acetabular outliers. Strong evidence exists that there is no difference in physical functioning, measured either by questionnaires or by gait analysis. Moderate evidence was found for a shorter length of hospital stay after MIS THA. Conflicting evidence was found for a positive effect of MIS THA on pain in the early postoperative period, but that effect diminished after three months postoperatively. Strong evidence was found for an increase in operative time for CAS THA, and limited evidence was found for a decrease in intraoperative blood loss. Furthermore, strong evidence was found for no difference in complication rates, as well as for a significantly lower risk for acetabular outliers. Conclusions The results indicate that MIS THA is a safe surgical procedure, without increases in operative time, blood loss, operative complication rates and component malposition rates. However, the beneficial effect of MIS THA on functional recovery has to be proven. The results also indicate that CAS THA, though resulting in an increase in operative time, may have a positive effect on operative blood loss and operative complication rates. More importantly, the use of CAS results in better positioning of acetabular component of the prosthesis. PMID:20470443

  12. Robot-assisted versus other types of radical prostatectomy: Population-based safety and cost comparison in Japan, 2012–2013

    PubMed Central

    Sugihara, Toru; Yasunaga, Hideo; Horiguchi, Hiromasa; Matsui, Hiroki; Fujimura, Tetsuya; Nishimatsu, Hiroaki; Fukuhara, Hiroshi; Kume, Haruki; Changhong, Yu; Kattan, Michael W; Fushimi, Kiyohide; Homma, Yukio

    2014-01-01

    In 2012, Japanese national insurance started covering robot-assisted surgery. We carried out a population-based comparison between robot-assisted and three other types of radical prostatectomy to evaluate the safety of robot-assisted prostatectomy during its initial year. We abstracted data for 7202 open, 2483 laparoscopic, 1181 minimal incision endoscopic, and 2126 robot-assisted radical prostatectomies for oncological stage T3 or less from the Diagnosis Procedure Combination database (April 2012–March 2013). Complication rate, transfusion rate, anesthesia time, postoperative length of stay, and cost were evaluated by pairwise one-to-one propensity-score matching and multivariable analyses with covariants of age, comorbidity, oncological stage, hospital volume, and hospital academic status. The proportion of robot-assisted radical prostatectomies dramatically increased from 8.6% to 24.1% during the first year. Compared with open, laparoscopic, and minimal incision endoscopic surgery, robot-assisted surgery was generally associated with a significantly lower complication rate (odds ratios, 0.25, 0.20, 0.33, respectively), autologous transfusion rate (0.04, 0.31, 0.10), homologous transfusion rate (0.16, 0.48, 0.14), lower cost excluding operation (differences, −5.1%, −1.8% [not significant], −10.8%) and shorter postoperative length of stay (–9.1%, +0.9% [not significant], –18.5%, respectively). However, robot-assisted surgery also resulted in a + 42.6% increase in anesthesia time and +52.4% increase in total cost compared with open surgery (all P < 0.05). Introduction of robotic surgery led to a dynamic change in prostate cancer surgery. Even in its initial year, robot-assisted radical prostatectomy was carried out with several favorable safety aspects compared to the conventional surgeries despite its having the longest anesthesia time and the highest cost. PMID:25183452

  13. Use of three-dimensional, CAD/CAM-assisted, virtual surgical simulation and planning in the pediatric craniofacial population.

    PubMed

    Gray, Rachel; Gougoutas, Alexander; Nguyen, Vinh; Taylor, Jesse; Bastidas, Nicholas

    2017-06-01

    Virtual Surgical Planning (VSP) and computer-aided design/computer-aided manufacturing (CAD/CAM) have recently helped improve efficiency and accuracy in many different craniofacial surgeries. Research has mainly focused on the use in the adult population with the exception of the use for mandibular distractions and cranial vault remodeling in the pediatric population. This study aims to elucidate the role of VSP and CAD/CAM in complex pediatric craniofacial cases by exploring its use in the correction of midface hypoplasia, orbital dystopia, mandibular reconstruction, and posterior cranial vault expansion. A retrospective analysis of thirteen patients who underwent 3d, CAD/CAM- assisted preoperative surgical planning between 2012 and 2016 was performed. All CAD/CAM assisted surgical planning was done in conjunction with a third party vendor (either 3D Systems or Materialise). Cutting and positioning guides as well as models were produced based on the virtual plan. Surgeries included free fibula mandible reconstruction (n = 4), lefort I osteotomy and distraction (n = 2), lefort II osteotomy with monobloc distraction (n = 1), expansion of the posterior vault for correction of chiari malformation (n = 3), and secondary orbital and midface reconstruction for facial trauma (n = 3). The patient's age, diagnosis, previous surgeries, length of operating time, complications, and post-surgery satisfaction were determined. In all cases we found presurgical planning was helpful to improve accuracy and significantly decrease intra-operative time. In cases where distraction was used, the planned and actual vectors were found to be accurate with excellent clinical outcomes. There were no complications except for one patient who experienced a wound infection post-operatively which did not alter the ultimate reconstruction. All patients experienced high satisfaction with their outcomes and excellent subjective aesthetic results were achieved. Preoperative planning using CAD/CAM and VSP allows for safe and precise craniofacial reconstruction in complex pediatric cases with a reduction of operative time. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Towards computer-assisted surgery in shoulder joint replacement

    NASA Astrophysics Data System (ADS)

    Valstar, Edward R.; Botha, Charl P.; van der Glas, Marjolein; Rozing, Piet M.; van der Helm, Frans C. T.; Post, Frits H.; Vossepoel, Albert M.

    A research programme that aims to improve the state of the art in shoulder joint replacement surgery has been initiated at the Delft University of Technology. Development of improved endoprostheses for the upper extremities (DIPEX), as this effort is called, is a clinically driven multidisciplinary programme consisting of many contributory aspects. A part of this research programme focuses on the pre-operative planning and per-operative guidance issues. The ultimate goal of this part of the DIPEX project is to create a surgical support infrastructure that can be used to predict the optimal surgical protocol and can assist with the selection of the most suitable endoprosthesis for a particular patient. In the pre-operative planning phase, advanced biomechanical models of the endoprosthesis fixation and the musculo-skeletal system of the shoulder will be incorporated, which are adjusted to the individual's morphology. Subsequently, the support infrastructure must assist the surgeon during the operation in executing his surgical plan. In the per-operative phase, the chosen optimal position of the endoprosthesis can be realised using camera-assisted tools or mechanical guidance tools. In this article, the pathway towards the desired surgical support infrastructure is described. Furthermore, we discuss the pre-operative planning phase and the per-operative guidance phase, the initial work performed, and finally, possible approaches for improving prosthesis placement.

  15. Using an In-House Approach to Computer-Assisted Design and Computer-Aided Manufacturing Reconstruction of the Maxilla.

    PubMed

    Numajiri, Toshiaki; Morita, Daiki; Nakamura, Hiroko; Tsujiko, Shoko; Yamochi, Ryo; Sowa, Yoshihiro; Toyoda, Kenichiro; Tsujikawa, Takahiro; Arai, Akihito; Yasuda, Makoto; Hirano, Shigeru

    2018-06-01

    Computer-assisted design (CAD) and computer-aided manufacturing (CAM) techniques are in widespread use for maxillofacial reconstruction. However, CAD/CAM surgical guides are commercially available only in limited areas. To use this technology in areas where these commercial guides are not available, the authors developed a CAD/CAM technique in which all processes are performed by the surgeon (in-house approach). The authors describe their experience and the characteristics of their in-house CAD/CAM reconstruction of the maxilla. This was a retrospective study of maxillary reconstruction with a free osteocutaneous flap. Free CAD software was used for virtual surgery and to design the cutting guides (maxilla and fibula), which were printed by a 3-dimensional printer. After the model surgery and pre-bending of the titanium plates, the actual reconstructions were performed. The authors compared the clinical information, preoperative plan, and postoperative reconstruction data. The reconstruction was judged as accurate if more than 80% of the reconstructed points were within a deviation of 2 mm. Although on-site adjustment was necessary in particular cases, all 4 reconstructions were judged as accurate. In total, 3 days were needed before the surgery for planning, printing, and pre-bending of plates. The average ischemic time was 134 minutes (flap suturing and bone fixation, 70 minutes; vascular anastomoses, 64 minutes). The mean deviation after reconstruction was 0.44 mm (standard deviation, 0.97). The deviations were 67.8% for 1 mm, 93.8% for 2 mm, and 98.6% for 3 mm. The disadvantages of the regular use of CAD/CAM reconstruction are the intraoperative changes in defect size and local tissue scarring. Good accuracy was obtained for CAD/CAM-guided reconstructions based on an in-house approach. The theoretical advantage of computer simulation contributes to the accuracy. An in-house approach could be an option for maxillary reconstruction. Copyright © 2017 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  16. An Automatic Registration Algorithm for 3D Maxillofacial Model

    NASA Astrophysics Data System (ADS)

    Qiu, Luwen; Zhou, Zhongwei; Guo, Jixiang; Lv, Jiancheng

    2016-09-01

    3D image registration aims at aligning two 3D data sets in a common coordinate system, which has been widely used in computer vision, pattern recognition and computer assisted surgery. One challenging problem in 3D registration is that point-wise correspondences between two point sets are often unknown apriori. In this work, we develop an automatic algorithm for 3D maxillofacial models registration including facial surface model and skull model. Our proposed registration algorithm can achieve a good alignment result between partial and whole maxillofacial model in spite of ambiguous matching, which has a potential application in the oral and maxillofacial reparative and reconstructive surgery. The proposed algorithm includes three steps: (1) 3D-SIFT features extraction and FPFH descriptors construction; (2) feature matching using SAC-IA; (3) coarse rigid alignment and refinement by ICP. Experiments on facial surfaces and mandible skull models demonstrate the efficiency and robustness of our algorithm.

  17. Integrating surgical robots into the next medical toolkit.

    PubMed

    Lai, Fuji; Entin, Eileen

    2006-01-01

    Surgical robots hold much promise for revolutionizing the field of surgery and improving surgical care. However, despite the potential advantages they offer, there are multiple barriers to adoption and integration into practice that may prevent these systems from realizing their full potential benefit. This study elucidated some of the most salient considerations that need to be addressed for integration of new technologies such as robotic systems into the operating room of the future as it evolves into a complex system of systems. We conducted in-depth interviews with operating room team members and other stakeholders to identify potential barriers in areas of workflow, teamwork, training, clinical acceptance, and human-system interaction. The findings of this study will inform an approach for the design and integration of robotics and related computer-assisted technologies into the next medical toolkit for "computer-enhanced surgery" to improve patient safety and healthcare quality.

  18. A Kalman-Filter-Based Common Algorithm Approach for Object Detection in Surgery Scene to Assist Surgeon's Situation Awareness in Robot-Assisted Laparoscopic Surgery

    PubMed Central

    2018-01-01

    Although the use of the surgical robot is rapidly expanding for various medical treatments, there still exist safety issues and concerns about robot-assisted surgeries due to limited vision through a laparoscope, which may cause compromised situation awareness and surgical errors requiring rapid emergency conversion to open surgery. To assist surgeon's situation awareness and preventive emergency response, this study proposes situation information guidance through a vision-based common algorithm architecture for automatic detection and tracking of intraoperative hemorrhage and surgical instruments. The proposed common architecture comprises the location of the object of interest using feature texture, morphological information, and the tracking of the object based on Kalman filter for robustness with reduced error. The average recall and precision of the instrument detection in four prostate surgery videos were 96% and 86%, and the accuracy of the hemorrhage detection in two prostate surgery videos was 98%. Results demonstrate the robustness of the automatic intraoperative object detection and tracking which can be used to enhance the surgeon's preventive state recognition during robot-assisted surgery. PMID:29854366

  19. Robot-assisted laparoscopic intracorporeal hand-sewn bowel anastomosis during pediatric bladder reconstructive surgery.

    PubMed

    Gundeti, Mohan S; Wiltz, Aimee L; Zagaja, Gregory P; Shalhav, Arieh L

    2010-08-01

    Bowel anastomosis performed during robot-assisted laparoscopic surgery in both adult and pediatric populations has typically been performed using endoscopic staplers or with exteriorization of the bowel. In the pediatric population, no articles have been published that explore the possibility of a completely intracorporeal hand-sewn anastomosis during robot-assisted laparoscopic surgery. We report our series of six children who were undergoing robot-assisted laparoscopic intracorporeal hand-sewn bowel anastomosis during bladder reconstructive surgery for neurogenic bladder. The postoperative course was uncomplicated with regard to the bowel anastomosis, demonstrating the feasibility of the technique in experienced hands.

  20. Through the HoloLens™ looking glass: augmented reality for extremity reconstruction surgery using 3D vascular models with perforating vessels.

    PubMed

    Pratt, Philip; Ives, Matthew; Lawton, Graham; Simmons, Jonathan; Radev, Nasko; Spyropoulou, Liana; Amiras, Dimitri

    2018-01-01

    Precision and planning are key to reconstructive surgery. Augmented reality (AR) can bring the information within preoperative computed tomography angiography (CTA) imaging to life, allowing the surgeon to 'see through' the patient's skin and appreciate the underlying anatomy without making a single incision. This work has demonstrated that AR can assist the accurate identification, dissection and execution of vascular pedunculated flaps during reconstructive surgery. Separate volumes of osseous, vascular, skin, soft tissue structures and relevant vascular perforators were delineated from preoperative CTA scans to generate three-dimensional images using two complementary segmentation software packages. These were converted to polygonal models and rendered by means of a custom application within the HoloLens™ stereo head-mounted display. Intraoperatively, the models were registered manually to their respective subjects by the operating surgeon using a combination of tracked hand gestures and voice commands; AR was used to aid navigation and accurate dissection. Identification of the subsurface location of vascular perforators through AR overlay was compared to the positions obtained by audible Doppler ultrasound. Through a preliminary HoloLens-assisted case series, the operating surgeon was able to demonstrate precise and efficient localisation of perforating vessels.

  1. Anatomy-based eligibility measure for robotic-assisted bypass surgery.

    PubMed

    Escoto, Abelardo; Trejos, Ana Luisa; Patel, Rajni V; Goela, Aashish; Kiaii, Bob

    2014-01-01

    Robotic-assisted endoscopic single-vessel small thoracotomy allows clinicians to perform coronary artery bypass grafting surgery in a minimally invasive manner using the da Vinci Surgical System. Not all patients are suitable for this technique, and the lack of an appropriate method for patient eligibility avoids completion of the procedure robotically. The objective of this study was to develop a patient eligibility method based on the anatomy of the chest of the patient. Preoperative computed tomography thorax scans of 110 patients were analyzed. Two-dimensional measurements taken on the axial images were used with the goal of finding a relation between the anatomy of the patient and the completion of the procedure robotically. Patients with a distance from the left anterior descending coronary artery to the anterior chest wall of smaller than 15 mm have a 20% probability of requiring conversion of the procedure to open surgery. This probability increases if the chest of the patient is very elliptical, having an anterior-posterior dimension of less than 45% of the transverse dimension. The smaller the distance is from the left anterior descending artery to the anterior chest wall, the lower the chances are of completing the procedure robotically.

  2. Transsphenoidal Approach in Endoscopic Endonasal Surgery for Skull Base Lesions: What Radiologists and Surgeons Need to Know.

    PubMed

    García-Garrigós, Elena; Arenas-Jiménez, Juan José; Monjas-Cánovas, Irene; Abarca-Olivas, Javier; Cortés-Vela, Jesús Julián; De La Hoz-Rosa, Javier; Guirau-Rubio, Maria Dolores

    2015-01-01

    In the last 2 decades, endoscopic endonasal transsphenoidal surgery has become the most popular choice of neurosurgeons and otolaryngologists to treat lesions of the skull base, with minimal invasiveness, lower incidence of complications, and lower morbidity and mortality rates compared with traditional approaches. The transsphenoidal route is the surgical approach of choice for most sellar tumors because of the relationship of the sphenoid bone to the nasal cavity below and the pituitary gland above. More recently, extended approaches have expanded the indications for transsphenoidal surgery by using different corridors leading to specific target areas, from the crista galli to the spinomedullary junction. Computer-assisted surgery is an evolving technology that allows real-time anatomic navigation during endoscopic surgery by linking preoperative triplanar radiologic images and intraoperative endoscopic views, thus helping the surgeon avoid damage to vital structures. Preoperative computed tomography is the preferred modality to show bone landmarks and vascular structures. Radiologists play an important role in surgical planning by reporting extension of sphenoid pneumatization, recesses and septations of the sinus, and other relevant anatomic variants. Radiologists should understand the relationships of the sphenoid bone and skull base structures, anatomic variants, and image-guided neuronavigation techniques to prevent surgical complications and allow effective treatment of skull base lesions with the endoscopic endonasal transsphenoidal approach. ©RSNA, 2015.

  3. Robot-assisted surgery in gynecological oncology: current status and controversies on patient benefits, cost and surgeon conditions - a systematic review.

    PubMed

    Kristensen, Steffen E; Mosgaard, Berit J; Rosendahl, Mikkel; Dalsgaard, Tórur; Bjørn, Signe F; Frøding, Ligita P; Kehlet, Henrik; Høgdall, Claus K; Lajer, Henrik

    2017-03-01

    Robot-assisted surgery has become more widespread in gynecological oncology. The purpose of this systematic review is to present current knowledge on robot-assisted surgery, and to clarify and discuss controversies that have arisen alongside the development and deployment. A database search in PubMed and EMBASE was performed up until 4 March 2016. The search strategy was developed in collaboration with an information specialist, and by application of the PRISMA guidelines. Human participants and English language were the only restrictive filters applied. Selection was performed by screening of titles and abstracts, and by full text scrutiny. From 2001 to 2016, a total of 76 references were included. Robot-assisted surgery in gynecological oncology has increased, and current knowledge supports that the oncological safety is similar, compared with previous surgical methods. Controversies arise because current knowledge does not clearly document the benefit of robot-assisted surgery, on perioperative outcome compared with the increased costs of the acquisition and application. The rapid development in robot-assisted surgery calls for long-term detailed prospective cohorts or randomized controlled trials. The costs associated with acquisition, application, and maintenance have an unfavorable impact on cost-benefit evaluations, especially when compared with laparoscopy. Future developments in robot-assisted surgery will hopefully lead to competition in the market, which will decrease costs. © 2016 Nordic Federation of Societies of Obstetrics and Gynecology.

  4. Imageless navigation system does not improve component rotational alignment in total knee arthroplasty.

    PubMed

    Cheng, Tao; Zhang, Guoyou; Zhang, Xianlong

    2011-12-01

    The aim of computer-assisted surgery is to improve accuracy and limit the range of surgical variability. However, a worldwide debate exists regarding the importance and usefulness of computer-assisted navigation for total knee arthroplasty (TKA). The main purpose of this study is to summarize and compare the radiographic outcomes of TKA performed using imageless computer-assisted navigation compared with conventional techniques. An electronic search of PubMed, EMBASE, Web of Science, and Cochrane library databases was made, in addition to manual search of major orthopedic journals. A meta-analysis of 29 quasi-randomized/randomized controlled trials (quasi-RCTs/RCTs) and 11 prospective comparative studies was conducted through a random effects model. Additional a priori sources of clinical heterogeneity were evaluated by subgroup analysis with regard to radiographic methods. When the outlier cut-off value of lower limb axis was defined as ±2° or ±3° from the neutral, the postoperative full-length radiographs demonstrated that the risk ratio was 0.54 or 0.39, respectively, which were in favor of the navigated group. When the cut-off value used for the alignment in the coronal and sagittal plane was 2° or 3°, imageless navigation significantly reduced the outlier rate of the femoral and tibial components compared with the conventional group. Notably, computed tomography scans demonstrated no statistically significant differences between the two groups regarding the outliers in the rotational alignment of the femoral and tibial components; however, there was strong statistical heterogeneity. Our results indicated that imageless computer-assisted navigation systems improve lower limb axis and component orientation in the coronal and sagittal planes, but not the rotational alignment in TKA. Further multiple-center clinical trials with long-term follow-up are needed to determine differences in the clinical and functional outcomes of knee arthroplasties performed using computer-assisted techniques. Copyright © 2011 Elsevier Inc. All rights reserved.

  5. Femtosecond laser-assisted cataract surgery in anterior lenticonus due to Alport syndrome.

    PubMed

    Barnes, Alexander C; Roth, Allen S

    2017-06-01

    We describe a case of bilateral anterior lenticonus in a patient with Alport syndrome treated with femtosecond laser-assisted cataract surgery (FLACS). FLACS was performed without complication, and a desirable postoperative visual acuity was achieved. Femtosecond laser-assisted cataract surgery is an effective approach for managing patients with anterior lenticonus secondary to Alport syndrome.

  6. The use of image-guidance during transsphenoidal pituitary surgery in the United States

    PubMed Central

    Chung, Thomas K.; Riley, Kristen O.

    2015-01-01

    Background: Intraoperative image guidance is a useful modality for transsphenoidal pituitary surgery. However, the outcomes associated with this technology have not been systematically evaluated. Objective: The purpose of the study was to quantify complication rates with and without the use of image guidance during transsphenoidal pituitary surgery using a nationwide database with broadly applicable results. Methods: A retrospective analysis of the Nationwide Inpatient Sample was performed from 2007 to 2011. Transsphenoidal pituitary resections for adenomas were identified by International Classification of Diseases-9th Revision, Clinical Modification code. The effect of image guidance on cerebrospinal fluid (CSF) leak complications and cost-benefit was analyzed. Results: A total of 48,848 transsphenoidal pituitary resections were identified, of which 77.5% were partial resections and 22.5% were complete. Pathologic indications included benign (89.3%), malignant primary (0.6%), and malignant secondary (0.4%). Complications included same-stay death (0.4%), CSF leak (8.8%), postoperative CSF rhinorrhea (1.9%), diabetes insipidus (12.4%), and meningitis (0.4%). Image guidance was employed in 7% (n = 3401) of all cases. When analyzed by modality, computed tomography (CT)-assisted procedures had lower CSF rhinorrhea rates (1.1%) compared with cases with no image guidance (1.9%), whereas magnetic resonance (MR)-assisted procedures had the highest rates (2.7%, χ2 p < 0.001). Rates of CSF leak demonstrated a similar pattern (CT 6.4%, no image guidance 8.9%, MR 9.2%, χ2 p < 0.001). CT-assisted surgery had significantly shorter length of stay (2.9 days) versus no image guidance (3.7 days, p < 0.001), lower total charges ($47,589 versus $62,629, p < 0.001), and lower total cost ($16,748 versus $20,530, p < 0.001). Conclusions: CT-assisted surgery is associated with a lower rate of CSF leak, shorter length of stay, and lower cost compared with patients without image guidance. Further studies that control for severity and extent of disease are warranted to confirm this finding. PMID:25975254

  7. Robot-assisted hysterectomy for endometrial and cervical cancers: a systematic review.

    PubMed

    Nevis, Immaculate F; Vali, Bahareh; Higgins, Caroline; Dhalla, Irfan; Urbach, David; Bernardini, Marcus Q

    2017-03-01

    Total and radical hysterectomies are the most common treatment strategies for early-stage endometrial and cervical cancers, respectively. Surgical modalities include open surgery, laparoscopy, and more recently, minimally invasive robot-assisted surgery. We searched several electronic databases for randomized controlled trials and observational studies with a comparison group, published between 2009 and 2014. Our outcomes of interest included both perioperative and morbidity outcomes. We included 35 observational studies in this review. We did not find any randomized controlled trials. The quality of evidence for all reported outcomes was very low. For women with endometrial cancer, we found that there was a reduction in estimated blood loss between the robot-assisted surgery compared to both laparoscopy and open surgery. There was a reduction in length of hospital stay between robot-assisted surgery and open surgery but not laparoscopy. There was no difference in total lymph node removal between the three modalities. There was no difference in the rate of overall complications between the robot-assisted technique and laparoscopy. For women with cervical cancer, there were no differences in estimated blood loss or removal of lymph nodes between robot-assisted and laparoscopic procedure. Compared to laparotomy, robot-assisted hysterectomy for cervical cancer showed an overall reduction in estimated blood loss. Although robot-assisted hysterectomy is clinically effective for the treatment of both endometrial and cervical cancers, methodologically rigorous studies are lacking to draw definitive conclusions.

  8. Detection and Localization of Robotic Tools in Robot-Assisted Surgery Videos Using Deep Neural Networks for Region Proposal and Detection.

    PubMed

    Sarikaya, Duygu; Corso, Jason J; Guru, Khurshid A

    2017-07-01

    Video understanding of robot-assisted surgery (RAS) videos is an active research area. Modeling the gestures and skill level of surgeons presents an interesting problem. The insights drawn may be applied in effective skill acquisition, objective skill assessment, real-time feedback, and human-robot collaborative surgeries. We propose a solution to the tool detection and localization open problem in RAS video understanding, using a strictly computer vision approach and the recent advances of deep learning. We propose an architecture using multimodal convolutional neural networks for fast detection and localization of tools in RAS videos. To the best of our knowledge, this approach will be the first to incorporate deep neural networks for tool detection and localization in RAS videos. Our architecture applies a region proposal network (RPN) and a multimodal two stream convolutional network for object detection to jointly predict objectness and localization on a fusion of image and temporal motion cues. Our results with an average precision of 91% and a mean computation time of 0.1 s per test frame detection indicate that our study is superior to conventionally used methods for medical imaging while also emphasizing the benefits of using RPN for precision and efficiency. We also introduce a new data set, ATLAS Dione, for RAS video understanding. Our data set provides video data of ten surgeons from Roswell Park Cancer Institute, Buffalo, NY, USA, performing six different surgical tasks on the daVinci Surgical System (dVSS) with annotations of robotic tools per frame.

  9. Applications of 3D orbital computer-assisted surgery (CAS).

    PubMed

    Scolozzi, P

    2017-09-01

    The purpose of the present report is to describe the indications for use of 3D orbital computer-assisted surgery (CAS). We analyzed the clinical and radiological data of all patients with orbital deformities treated using intra-operative navigation and CAD/CAM techniques at the Hôpitaux Universitaires de Genève, Switzerland, between 2009 and 2016. We recorded age and gender, orbital deformity, technical and surgical procedure and postoperative complications. One hundred and three patients were included. Mean age was 39.5years (range, 5 to 84years) and 85 (87.5%) were men. Of the 103 patients, 96 had intra-operative navigation (34 for primary and 3 for secondary orbito-zygomatic fractures, 15 for Le Fort fractures, 16 for orbital floor fractures, 10 for combined orbital floor and medial wall fractures, 7 for orbital medial wall fractures, 3 for NOE (naso-orbito-ethmoidal) fractures, 2 for isolated comminuted zygomatic arch fractures, 1 for enophthalmos, 3 for TMJ ankylosis and 2 for fibrous dysplasia bone recontouring), 8 patients had CAD/CAM PEEK-PSI for correction of residual orbital bone contour following craniomaxillofacial trauma, and 1 patient had CAD/CAM surgical splints and cutting guides for correction of orbital hypertelorism. Two patient (1.9%) required revision surgery for readjustment of an orbital mesh. The 1-year follow-up examination showed stable cosmetic and dimensional results in all patients. This study demonstrated that the application of 3D orbital CAS with regards to intra-operative navigation and CAD/CAM techniques allowed for a successful outcome in the patients presented in this series. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  10. Video-assisted minithoracotomy for blunt diaphragmatic rupture presenting as a delayed hemothorax.

    PubMed

    Ota, Hideki; Kawai, Hideki; Matsuo, Tsubasa

    2014-01-01

    Diaphragmatic ruptures after blunt trauma are rare life-threatening conditions. Most of them occur on the left-sided hemidiaphragm with herniation or associated organ injuries after a motor vehicle accident. We present an unusual case of blunt diaphragmatic rupture resulting in a delayed hemothorax. A 62-year-old man presented with acute dyspnea that initiated while straining to pass stool. He had a bruise on the lower back region of his right thorax after a slip-and-fall accident 7 days previously. Chest computed tomographic scans revealed a right-sided hemothorax without any evidence of herniation or associated organ injuries. Emergency surgery was performed through a video-assisted minithoracotomy. During surgery, we identified a diaphragmatic laceration with a severed blood vessel originating from the right superior phrenic artery. The lesion was repaired with interrupted horizontal mattress sutures. The total amount of bleeding was approximately 2000 mL. The patient had an uneventful recovery with no further bleeding episodes.

  11. Technology advances in hospital practices: robotics in treatment of patients.

    PubMed

    Rosiek, Anna; Leksowski, Krzysztof

    2015-06-01

    Laparoscopic cholecystectomy is widely considered as the treatment of choice for acute cholecystitis. The safety of the procedure and its minimal invasiveness made it a valid treatment option for a patient not responding to antibiotic therapy. Our research shows that patients positively assess this treatment method, but the world's tendency is to turn to a more sophisticated method utilizing robot-assisted surgery as a gold standard. Providing patient with minimally invasive surgical procedures that utilize the state-of-the-art equipment like the da Vinci Robotic Surgical System underscores the commitment to high-quality patient care while enhancing patient safety. The advantages include minimal invasive scarring, less pain and bleeding, faster recovery time, and shorter hospital stay. The move toward less invasive and less morbid procedures and a need to re-create the true open surgical experience have paved the way for the development and application of robotic and computer-assisted systems in surgery in Poland as well as the rest of the world. © The Author(s) 2014.

  12. The operation of the century: total hip replacement.

    PubMed

    Learmonth, Ian D; Young, Claire; Rorabeck, Cecil

    2007-10-27

    In the 1960s, total hip replacement revolutionised management of elderly patients crippled with arthritis, with very good long-term results. Today, young patients present for hip-replacement surgery hoping to restore their quality of life, which typically includes physically demanding activities. Advances in bioengineering technology have driven development of hip prostheses. Both cemented and uncemented hips can provide durable fixation. Better materials and design have allowed use of large-bore bearings, which provide an increased range of motion with enhanced stability and very low wear. Minimally invasive surgery limits soft-tissue damage and facilitates accelerated discharge and rehabilitation. Short-term objectives must not compromise long-term performance. Computer-assisted surgery will contribute to reproducible and accurate placement of implants. Universal economic constraints in healthcare services dictate that further developments in total hip replacement will be governed by their cost-effectiveness.

  13. Recent advances in fixation of the craniomaxillofacial skeleton.

    PubMed

    Meslemani, Danny; Kellman, Robert M

    2012-08-01

    Fixation of the craniomaxillofacial skeleton is an evolving aspect for facial plastic, oral and maxillofacial, and plastic surgery. This review looks at the recent advances that aid in reduction and fixation of the craniomaxillofacial skeleton. More surgeons are using resorbable plates for craniomaxillofacial fixation. A single miniplate on the inferior border of the mandible may be sufficient to reduce and fixate an angle fracture. Percutaneous K-wires may assist in plating angle fractures. Intraoperative computed tomography (CT) may prove to be useful for assessing reduction and fixation. Resorbable plates are becoming increasingly popular in orthognathic surgery and facial trauma surgery. There are newer operative techniques for fixating the angle of the mandible. Also, the utilization of the intraoperative CT provides immediate feedback for accurate reduction and fixation. Prebent surgical plates save operative time, decrease errors, and provide more accurate fixation.

  14. Robot-assisted surgery in elderly and very elderly population: our experience in oncologic and general surgery with literature review.

    PubMed

    Ceccarelli, Graziano; Andolfi, Enrico; Biancafarina, Alessia; Rocca, Aldo; Amato, Maurizio; Milone, Marco; Scricciolo, Marta; Frezza, Barbara; Miranda, Egidio; De Prizio, Marco; Fontani, Andrea

    2017-02-01

    Although there is no agreement on a definition of elderly, commonly an age cutoff of ≥65 or 75 years is used. Nowadays most of malignancies requiring surgical treatment are diagnosed in old population. Comorbidities and frailty represent well-known problems during and after surgery in elderly patients. Minimally invasive surgery offers earlier postoperative mobilization, less blood loss, lower morbidity as well as reduction in hospital stay and as such represents an interesting and validated option for elderly population. Robot-assisted surgery is a recent improvement of conventional minimally invasive surgery. We provided a complete review of old and very old patients undergoing robot-assisted surgery for oncologic and general surgery interventions. A retrospective review of all patients undergoing robot-assisted surgery in our General Surgery Unit from September 2012 to June 2016 was conducted. Analysis was performed for the entire cohort and in particular for three of the most performed surgeries (gastric resections, right colectomy, and liver resections) classifying patients into three age groups: ≤64, 65-79, and ≥80. Data from these three different age groups were compared and examined in respect of different outcomes: ASA score, comorbidities, oncologic outcomes, conversion rate, estimated blood loss, hospital stay, geriatric events, mortality, etc. Using our in-patient robotic surgery database, we retrospectively examined 363 patients, who underwent robot-assisted surgery for different diseases (402 different robotic procedures): colorectal surgery, upper GI, HPB, etc.; the oncologic procedures were 81%. Male were 56%. The mean age was 65.63 years (18-89). Patients aged ≥65 years represented 61% and ≥80 years 13%. Overall conversion rate was of 6%, most in the group 65-79 years (59% of all conversions). The more frequent diseases treated were colorectal surgery 43%, followed by hepatobilopancreatic surgery 23.4%, upper gastro-intestinal 23.2%, and others 10.4%. Robot-assisted surgery is a safe and effective technique in aging patient population too. There was no increased risk of death or morbidity compared to younger patients in the three groups examined. A higher conversion rate was observed in our experience for patients aged 65-79. Prolonged operative time and in any cases steep positions (Trendelenburg) have not represented a problem for the majority of patients. In any case, considering the high direct costs, minimally invasive robot-assisted surgery should be performed on a case-by-case basis, tailored to each patient with their specific histories and comorbidities.

  15. [Prostatectomy-pros and cons on open surgery/laparoscopic surgery/robot-assisted surgery].

    PubMed

    Abe, Mitsuhiro; Kawano, Yoshiyuki; Kameyama, Shuji

    2011-12-01

    We have 3 options when perfoming prostatectomy for the treatment of localized prostate cancer. Those are retropubic radical prostatectomy, laparoscopic radical prostatectomy and robot-assisted laparoscopic radical prostatectomy. We compared the characteristics and results of these techniques. Robot-assisted laparoscopic radical prostatectomy could be superior to the others in many ways. However, it would be very difficult to adopt it in Japan because it would pose economical difficulties. The administrative assistance in the insurance systems requireds much more than we have.

  16. Three years of biomedical FEL use in medicine and surgery How far have we come?

    NASA Astrophysics Data System (ADS)

    Jean, Benedikt

    1997-02-01

    Since the FEL has been made available for biophysical research in the IR, it has revolutionized the optimization strategies of laser-tissue interaction and the minimizing of adverse effects, in particular for photoablative use in surgery. Its tunability together with the free combination of wavelength and energy made it an efficient research tool, allowing the reduction of risks and costs of preclinical biomedical research. New computer-assisted surgical techniques evolved and the broader data basis of IR photothermal ablation allows more accurate predictive modelling of the efficiency and the adverse effects of photoablation. New applications for diagnostic imaging as well as the first clinical applications in neurosurgery lay ahead.

  17. Medical image computing for computer-supported diagnostics and therapy. Advances and perspectives.

    PubMed

    Handels, H; Ehrhardt, J

    2009-01-01

    Medical image computing has become one of the most challenging fields in medical informatics. In image-based diagnostics of the future software assistance will become more and more important, and image analysis systems integrating advanced image computing methods are needed to extract quantitative image parameters to characterize the state and changes of image structures of interest (e.g. tumors, organs, vessels, bones etc.) in a reproducible and objective way. Furthermore, in the field of software-assisted and navigated surgery medical image computing methods play a key role and have opened up new perspectives for patient treatment. However, further developments are needed to increase the grade of automation, accuracy, reproducibility and robustness. Moreover, the systems developed have to be integrated into the clinical workflow. For the development of advanced image computing systems methods of different scientific fields have to be adapted and used in combination. The principal methodologies in medical image computing are the following: image segmentation, image registration, image analysis for quantification and computer assisted image interpretation, modeling and simulation as well as visualization and virtual reality. Especially, model-based image computing techniques open up new perspectives for prediction of organ changes and risk analysis of patients and will gain importance in diagnostic and therapy of the future. From a methodical point of view the authors identify the following future trends and perspectives in medical image computing: development of optimized application-specific systems and integration into the clinical workflow, enhanced computational models for image analysis and virtual reality training systems, integration of different image computing methods, further integration of multimodal image data and biosignals and advanced methods for 4D medical image computing. The development of image analysis systems for diagnostic support or operation planning is a complex interdisciplinary process. Image computing methods enable new insights into the patient's image data and have the future potential to improve medical diagnostics and patient treatment.

  18. Computer-assisted planning and patient-specific guides for the treatment of midshaft clavicle malunions.

    PubMed

    Vlachopoulos, Lazaros; Schweizer, Andreas; Meyer, Dominik C; Gerber, Christian; Fürnstahl, Philipp

    2017-08-01

    The surgical treatment of malunions after midshaft clavicle fractures is associated with a number of potential complications and the surgical procedure is challenging. However, with appropriate and meticulous preoperative surgical planning, the surgical correction yields satisfactory results. The purpose of this study was to provide a guideline and detailed overview for the computer-assisted planning and 3-dimensional (3D) correction of malunions of the clavicle. The 3D bone surface models of the pathologic and contralateral sides were created on the basis of computed tomography data. The computer-assisted assessment of the deformity, the preoperative plan, and the design of patient-specific guides enabling compression plating are described. We demonstrate the benefit and versatility of computer-assisted planning for corrective osteotomies of malunions of the midshaft clavicle. In combination with patient-specific guides and compression plating technique, the correction can be performed in a more standardized fashion. We describe the determination of the contact-optimized osteotomy plane. An osteotomy along this plane facilitates the correction and enlarges the contact between the fragments at once. We further developed a technique of a stepped osteotomy that is based on the calculation of the contact-optimized osteotomy plane. The stepped osteotomy enables the length to be restored without the need of structural bone graft. The application of the stepped osteotomy is presented for malunions of the clavicle with shortening and excessive callus formation. The 3D preoperative planning and patient-specific guides for corrective osteotomies of the clavicle may help reduce the number of potential complications and yield results that are more predictable. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  19. Robotic assisted laparoscopic partial nephrectomy using contrast-enhanced ultrasound scan to map renal blood flow.

    PubMed

    Alenezi, Ahmad; Motiwala, Aamir; Eves, Susannah; Gray, Rob; Thomas, Asha; Meiers, Isabelle; Sharif, Haytham; Motiwala, Hanif; Laniado, Marc; Karim, Omer

    2017-03-01

    The paper describes novel real-time 'in situ mapping' and 'sequential occlusion angiography' to facilitate selective ischaemia robotic partial nephrectomy (RPN) using intraoperative contrast enhanced ultrasound scan (CEUS). Data were collected and assessed for 60 patients (61 tumours) between 2009 and 2013. 31 (50.8%) tumours underwent 'Global Ischaemia', 27 (44.3%) underwent 'Selective Ischaemia' and 3 (4.9%) were removed 'Off Clamp Zero Ischaemia'. Demographics, operative variables, complications, renal pathology and outcomes were assessed. Median PADUA score was 9 (range 7-10). The mean warm ischaemia time in selective ischaemia was less and statistically significant than in global ischaemia (17.1 and 21.4, respectively). Mean operative time was 163 min. Postoperative complications (n = 10) included three (5%) Clavien grade 3 or above. Malignancy was demonstrated in 47 (77%) with negative margin in 43 (91.5%) and positive margin in four (8.5%). Long-term decrease in eGFR post selective ischaemia robotic partial nephrectomy was less compared with global ischaemia (four and eight, respectively) but not statistically significant. This technique is safe, feasible and cost-effective with comparable perioperative outcomes. The technical aspects elucidate the role of intraoperative CEUS to facilitate and ascertain selective ischaemia. Further work is required to demonstrate long-term oncological outcomes. © 2016 The Authors. The International Journal of Medical Robotics and Computer Assisted Surgery published by John Wiley & Sons, Ltd. © 2016 The Authors. The International Journal of Medical Robotics and Computer Assisted Surgery published by John Wiley & Sons, Ltd.

  20. A technical innovation for improving identification of the trackers by the LED cameras in navigation-assisted total knee arthroplasty.

    PubMed

    Darmanis, Spyridon; Toms, Andrew; Durman, Robert; Moore, Donna; Eyres, Keith

    2007-07-01

    To reduce the operating time in computer-assisted navigated total knee replacement (TKR), by improving communication between the infrared camera and the trackers placed on the patient. The innovation involves placing a routinely used laser pointer on top of the camera, so that the infrared cameras focus precisely on the trackers located on the knee to be operated on. A prospective randomized study was performed involving 40 patients divided into two groups, A and B. Both groups underwent navigated TKR, but for group B patients a laser pointer was used to improve the targeting capabilities of the cameras. Without the laser pointer, the camera had to move a mean 9.2 times in order to identify the trackers. With the introduction of the laser pointer, this was reduced to 0.9 times. Accordingly, the additional mean time required without the laser pointer was 11.6 minutes. Time delays are a major problem in computer-assisted surgery, and our technical suggestion can contribute towards reducing the delays associated with this particular application.

  1. The Evolution of Computer-Assisted Total Hip Arthroplasty and Relevant Applications.

    PubMed

    Chang, Jun-Dong; Kim, In-Sung; Bhardwaj, Atul M; Badami, Ramachandra N

    2017-03-01

    In total hip arthroplasty (THA), the accurate positioning of implants is the key to achieve a good clinical outcome. Computer-assisted orthopaedic surgery (CAOS) has been developed for more accurate positioning of implants during the THA. There are passive, semi-active, and active systems in CAOS for THA. Navigation is a passive system that only provides information and guidance to the surgeon. There are 3 types of navigation: imageless navigation, computed tomography (CT)-based navigation, and fluoroscopy-based navigation. In imageless navigation system, a new method of registration without the need to register the anterior pelvic plane was introduced. CT-based navigation can be efficiently used for pelvic plane reference, the functional pelvic plane in supine which adjusts anterior pelvic plane sagittal tilt for targeting the cup orientation. Robot-assisted system can be either active or semi-active. The active robotic system performs the preparation for implant positioning as programmed preoperatively. It has been used for only femoral implant cavity preparation. Recently, program for cup positioning was additionally developed. Alternatively, for ease of surgeon acceptance, semi-active robot systems are developed. It was initially applied only for cup positioning. However, with the development of enhanced femoral workflows, this system can now be used to position both cup and stem. Though there have been substantial advancements in computer-assisted THA, its use can still be controversial at present due to the steep learning curve, intraoperative technical issues, high cost and etc. However, in the future, CAOS will certainly enable the surgeon to operate more accurately and lead to improved outcomes in THA as the technology continues to evolve rapidly.

  2. Robotic thoracic surgery: technical considerations and learning curve for pulmonary resection.

    PubMed

    Veronesi, Giulia

    2014-05-01

    Retrospective series indicate that robot-assisted approaches to lung cancer resection offer comparable radicality and safety to video-assisted thoracic surgery or open surgery. More intuitive movements, greater flexibility, and high-definition three-dimensional vision overcome limitations of video-assisted thoracic surgery and may encourage wider adoption of robotic surgery for lung cancer, particularly as more early stage cases are diagnosed by screening. High capital and running costs, limited instrument availability, and long operating times are important disadvantages. Entry of competitor companies should drive down costs. Studies are required to assess quality of life, morbidity, oncologic radicality, and cost effectiveness. Copyright © 2014 Elsevier Inc. All rights reserved.

  3. Anesthetic Challenges in Robotic-assisted Urologic Surgery

    PubMed Central

    Hsu, Richard L; Kaye, Alan D; Urman, Richard D

    2013-01-01

    Robotic-assisted surgery has evolved over the past two decades with constantly improving technology, assisting surgeons in multiple subspecialty disciplines. The surgical requirements of lithotomy and steep Trendelenburg positions, along with the creation of a pneumoperitoneum and limited access to the patient, all present anesthetic management challenges in urologic surgery. Patient positioning requirements can cause significant physiologic effects and may result in many complications. Good communication among team members and knowledge of the nuances of robotic surgery have the potential to improve patient outcomes, increase efficiency, and reduce surgical and anesthetic complications. PMID:24659914

  4. Virtual reality surgical simulators- a prerequisite for robotic surgery.

    PubMed

    Rajanbabu, Anupama; Drudi, Laura; Lau, Susie; Press, Joshua Z; Gotlieb, Walter H

    2014-06-01

    The field of computer assisted minimally invasive surgery is rapidly expanding worldwide, including in India. With more hospitals in India contemplating the acquisition of a robotic platform, training of robotic surgeons is becoming essential. Virtual reality simulators can be used for surgeons to become acquainted with the robotic console prior to live surgery. Our aim was to evaluate the amount of simulator training required before a surgeon first operates on the da Vinci® Surgical System. Simulations were conducted on the Intuitive Surgical's da Vinci® Robot Skill Simulator using the software obtained from Mimic Technologies. Participants included attending staff surgeons experienced in robotic surgery and novices. A set of seven activities were chosen for each participant. Based on the mean exercise score from the first attempt, staff surgeons outperformed the novices in all exercises. However, the difference in score between the staff and the novices decreased after the participants repeated the exercises and by the sixth attempt most of the novices obtained similar scores to the staff, suggesting that this might be at present the minimum set of repetitions indicated (or required) prior to performing life robotic surgery.

  5. Robotic surgery in gynecologic cancer.

    PubMed

    Yim, Ga Won; Kim, Young Tae

    2012-02-01

    The development of robotic technology has facilitated the application of minimally invasive techniques for complex operations in gynecologic oncology. The objective of this article is to review the published literature regarding robotic surgery and its application to gynecologic cancer. To date, 20 articles addressing radical hysterectomy, six articles of radical trachelectomy, seven articles of surgical procedure in advanced or recurrent cervical cancer, 14 articles of endometrial cancer staging, and two articles solely on ovarian cancer all performed robotically are published in the literature. The majority of publications on robotic surgery are still retrospective or descriptive in nature. However, the data for gynecologic cancer show comparable results of robotic surgery compared with laparoscopy or laparotomy in terms of blood loss, length of hospital stay, and complications. Computer-enhanced technology with its associated benefits appears to facilitate the surgical approach for technically challenging operations performed to treat selected cases of cervical, endometrial, and ovarian cancer as evidenced by the current literature. Continued research and clinical trials are needed to further elucidate the equivalence or superiority of robot-assisted surgery to conventional methods in terms of oncologic outcome and patients' quality of life.

  6. Early assessment of the likely cost-effectiveness of a new technology: A Markov model with probabilistic sensitivity analysis of computer-assisted total knee replacement.

    PubMed

    Dong, Hengjin; Buxton, Martin

    2006-01-01

    The objective of this study is to apply a Markov model to compare cost-effectiveness of total knee replacement (TKR) using computer-assisted surgery (CAS) with that of TKR using a conventional manual method in the absence of formal clinical trial evidence. A structured search was carried out to identify evidence relating to the clinical outcome, cost, and effectiveness of TKR. Nine Markov states were identified based on the progress of the disease after TKR. Effectiveness was expressed by quality-adjusted life years (QALYs). The simulation was carried out initially for 120 cycles of a month each, starting with 1,000 TKRs. A discount rate of 3.5 percent was used for both cost and effectiveness in the incremental cost-effectiveness analysis. Then, a probabilistic sensitivity analysis was carried out using a Monte Carlo approach with 10,000 iterations. Computer-assisted TKR was a long-term cost-effective technology, but the QALYs gained were small. After the first 2 years, the incremental cost per QALY of computer-assisted TKR was dominant because of cheaper and more QALYs. The incremental cost-effectiveness ratio (ICER) was sensitive to the "effect of CAS," to the CAS extra cost, and to the utility of the state "Normal health after primary TKR," but it was not sensitive to utilities of other Markov states. Both probabilistic and deterministic analyses produced similar cumulative serious or minor complication rates and complex or simple revision rates. They also produced similar ICERs. Compared with conventional TKR, computer-assisted TKR is a cost-saving technology in the long-term and may offer small additional QALYs. The "effect of CAS" is to reduce revision rates and complications through more accurate and precise alignment, and although the conclusions from the model, even when allowing for a full probabilistic analysis of uncertainty, are clear, the "effect of CAS" on the rate of revisions awaits long-term clinical evidence.

  7. Multimedia patient education to assist the informed consent process for knee arthroscopy.

    PubMed

    Cornoiu, Andrei; Beischer, Andrew D; Donnan, Leo; Graves, Stephen; de Steiger, Richard

    2011-03-01

    In contemporary clinical practice, the ability for orthopaedic surgeons to obtain true 'informed consent' is becoming increasingly difficult. This problem has been driven by factors including increased expectations of surgical outcome by patients and increasing complexity of surgical procedures. Surgical pamphlets and computer presentations have been advocated as ways of improving patient education, but evidence of their efficacy is limited. The aim of this study was to compare the efficacy of a computer-based multimedia (MM) presentation against standardized verbal consent and information pamphlets for patients considering knee arthroscopy surgery. A randomized, controlled prospective trial was conducted, comparing the efficacy of three methods of providing preoperative informed consent information to patients. Sixty-one patients were randomly allocated into MM, verbal consent or pamphlet groups 3-6 weeks prior to knee arthroscopy surgery. Information recall after the initial consent process was assessed by questionnaire. Retention of this information was again assessed by questionnaire at the time of surgery and 6 weeks after surgery. The MM group demonstrated a significantly greater proportion of correct responses, 98%, in the questionnaire at the time of consent, in comparison with 88% for verbal and 76% for pamphlet groups, with no difference in anxiety levels. Information was also better retained by the MM group up to 6 weeks after surgery. Patient satisfaction with information delivery was higher in the MM group. MM is an effective tool for aiding in the provision and retention of information during the informed consent process. © 2010 The Authors. ANZ Journal of Surgery © 2010 Royal Australasian College of Surgeons.

  8. Transesophageal Echocardiography-Guided Epicardial Left Ventricular Lead Placement by Video-Assisted Thoracoscopic Surgery in Nonresponders to Biventricular Pacing and Previous Chest Surgery.

    PubMed

    Schroeder, Carsten; Chung, Jane M; Mackall, Judith A; Cakulev, Ivan T; Patel, Aaron; Patel, Sunny J; Hoit, Brian D; Sahadevan, Jayakumar

    2018-06-14

    The aim of the study was to study the feasibility, safety, and efficacy of transesophageal echocardiography-guided intraoperative left ventricular lead placement via a video-assisted thoracoscopic surgery approach in patients with failed conventional biventricular pacing. Twelve patients who could not have the left ventricular lead placed conventionally underwent epicardial left ventricular lead placement by video-assisted thoracoscopic surgery. Eight patients had previous chest surgery (66%). Operative positioning was a modified far lateral supine exposure with 30-degree bed tilt, allowing for groin and sternal access. To determine the optimal left ventricular location for lead placement, the left ventricular surface was divided arbitrarily into nine segments. These segments were transpericardially paced using a hand-held malleable pacing probe identifying the optimal site verified by transesophageal echocardiography. The pacing leads were screwed into position via a limited pericardiotomy. The video-assisted thoracoscopic surgery approach was successful in all patients. Biventricular pacing was achieved in all patients and all reported symptomatic benefit with reduction in New York Heart Association class from III to I-II (P = 0.016). Baseline ejection fraction was 23 ± 3%; within 1-year follow-up, the ejection fraction increased to 32 ± 10% (P = 0.05). The mean follow-up was 566 days. The median length of hospital stay was 7 days with chest tube removal between postoperative days 2 and 5. In patients who are nonresponders to conventional biventricular pacing, intraoperative left ventricular lead placement using anatomical and functional characteristics via a video-assisted thoracoscopic surgery approach is effective in improving heart failure symptoms. This optimized left ventricular lead placement is feasible and safe. Previous chest surgery is no longer an exclusion criterion for a video-assisted thoracoscopic surgery approach.

  9. Modified single-port non-intubated video-assisted thoracoscopic decortication in high-risk parapneumonic empyema patients.

    PubMed

    Hsiao, Chen-Hao; Chen, Ke-Cheng; Chen, Jin-Shing

    2017-04-01

    Parapneumonic empyema patients with coronary artery disease and reduced left ventricular ejection fraction are risky to receive surgical decortication under general anesthesia. Non-intubated video-assisted thoracoscopy surgery is successfully performed to avoid complications of general anesthesia. We performed single-port non-intubated video-assisted flexible thoracoscopy surgery in an endoscopic center. In this study, the possible role of our modified surgery to treat fibrinopurulent stage of parapneumonic empyema with high operative risks is investigated. We retrospectively reviewed fibrinopurulent stage of parapneumonic empyema patients between July 2011 and June 2014. Thirty-three patients with coronary artery disease and reduced left ventricular ejection fraction were included in this study. One group received tube thoracostomy, and the other group received single-port non-intubated video-assisted flexible thoracoscopy surgery decortication. Patient demographics, characteristics, laboratory findings, etiology, and treatment outcomes were compared. Mean age of 33 patients (24 males, 9 females) was 76.2 ± 9.7 years. Twelve patients received single-port non-intubated video-assisted flexible thoracoscopy surgery decortication, and 21 patients received tube thoracostomy. Visual analog scale scores on postoperative first hour and first day were not significantly different in two groups (p value = 0.5505 and 0.2750, respectively). Chest tube drainage days, postoperative fever subsided days, postoperative hospital days, and total length of stay were significantly short in single-port non-intubated video-assisted flexible thoracoscopy surgery decortication (p value = 0.0027, 0.0001, 0.0009, and 0.0065, respectively). Morbidities were low, and mortality was significantly low (p value = 0.0319) in single-port non-intubated video-assisted flexible thoracoscopy surgery decortication. Single-port non-intubated video-assisted flexible thoracoscopy surgery decortication may be suggested to be a method other than tube thoracostomy to deal with fibrinopurulent stage of parapneumonic empyema patients with coronary artery disease and reduced left ventricular ejection fraction.

  10. False ankylosis of the temporomandibular joint in a cat. Correction by partial zygomatic arch resection.

    PubMed

    Larguier, L; Jamet, N

    2015-01-01

    To describe the use of two-dimensional computer-assisted tomography (CT) with three-dimensional (3D) reconstruction in the diagnosis and planning of surgical treatment of a case of false ankylosis of the temporomandibular joint. A young European Shorthaired cat was presented with the complaint of inability to eat and open its jaws. A CT scan with 3D reconstruction allowed visualization of the lesion which was causing extra-articular ankylosis of the temporomandibular joint. Surgery was performed to resect an osseous lesion of the zygomatic arch, thus freeing the temporomandibular joint. Postoperative physical therapy was initiated immediately following surgery, and then carried out by the owner with a one year follow-up. Clinical examination of the cat was performed during regular office visits (at 1 month and 3 months following surgery), which allowed objective assessment of postoperative recuperation. At the end of a year, the owners reported that the cat had maintained sufficient jaw opening without any signs consistent with chronic pain. Computed tomography scan with 3D reconstruction allowed planning of the surgical correction of extra-articular ankylosis of the temporomandibular joint, and in this case condylectomy was avoided, since temporomandibular joint range-of-motion was maintained.

  11. Augmented reality in the surgery of cerebral aneurysms: a technical report.

    PubMed

    Cabrilo, Ivan; Bijlenga, Philippe; Schaller, Karl

    2014-06-01

    Augmented reality is the overlay of computer-generated images on real-world structures. It has previously been used for image guidance during surgical procedures, but it has never been used in the surgery of cerebral aneurysms. To report our experience of cerebral aneurysm surgery aided by augmented reality. Twenty-eight patients with 39 unruptured aneurysms were operated on in a prospective manner with augmented reality. Preoperative 3-dimensional image data sets (angio-magnetic resonance imaging, angio-computed tomography, and 3-dimensional digital subtraction angiography) were used to create virtual segmentations of patients' vessels, aneurysms, aneurysm necks, skulls, and heads. These images were injected intraoperatively into the eyepiece of the operating microscope. An example case of an unruptured posterior communicating artery aneurysm clipping is illustrated in a video. The described operating procedure allowed continuous monitoring of the accuracy of patient registration with neuronavigation data and assisted in the performance of tailored surgical approaches and optimal clipping with minimized exposition. Augmented reality may add to the performance of a minimally invasive approach, although further studies need to be performed to evaluate whether certain groups of aneurysms are more likely to benefit from it. Further technological development is required to improve its user friendliness.

  12. Computer assisted outcomes research in orthopedics: total joint replacement.

    PubMed

    Arslanian, C; Bond, M

    1999-06-01

    Long-term studies are needed to determine clinically relevant outcomes within the practice of orthopedic surgery. Historically, the patient's subjective feelings of quality of life have been largely ignored. However, there has been a strong movement toward measuring perceived quality of life through such instruments as the SF-36. In a large database from an orthopedic practice results are presented. First, computerized data entry using touch screen technology is not only cost effective but user friendly. Second, patients undergoing hip or knee arthroplasty surgeries make statistically significant improvements in seven of the eight domains of the SF-36 in the first 3 months after surgery. Additional statistically significant improvements over the next 6 to 12 months are also seen. The data are presented here in detail to demonstrate the benefits of a patient outcomes program, to enhance the understanding and use of outcomes data and to encourage further work in outcomes measurement in orthopedics.

  13. Latest trends in craniomaxillofacial surgical instrumentation.

    PubMed

    Yim, Michael; Demke, Joshua

    2012-08-01

    To review the past year's literature regarding recent innovations in surgical instrumentation for craniomaxillofacial surgery. Current advances in surgical instrumentation have led to many improvements in the field, allowing greater visualization and precision both before and during procedures. One of the common goals is to achieve excellent outcomes with minimal complications, while at the same time minimizing invasiveness of surgery. Highlighted innovations include greater capacities for acquisition of data, leading to improved imaging modalities and expansion of computer-assisted surgical techniques; continued developments in biomaterials used in various reconstructions; and novel uses of bone cutting and bone fixation instrumentation. Technology in the field of craniomaxillofacial surgery is developing rapidly, leading to novel instrumentation being utilized across a broad spectrum of areas. Published data have been encouraging to date, indicating an ever increasing adaptation of these innovations in clinical practice. Future efforts need to focus on cost-benefit analysis and constructing larger-scale studies to better understand effectiveness and patient outcomes.

  14. The smiling scan technique: Facially driven guided surgery and prosthetics.

    PubMed

    Pozzi, Alessandro; Arcuri, Lorenzo; Moy, Peter K

    2018-04-11

    To introduce a proof of concept technique and new integrated workflow to optimize the functional and esthetic outcome of the implant-supported restorations by means of a 3-dimensional (3D) facially-driven, digital assisted treatment plan. The Smiling Scan technique permits the creation of a virtual dental patient (VDP) showing a broad smile under static conditions. The patient is exposed to a cone beam computed tomography scan (CBCT), displaying a broad smile for the duration of the examination. Intraoral optical surface scanning (IOS) of the dental and soft tissue anatomy or extraoral optical surface scanning (EOS) of the study casts are achieved. The superimposition of the digital imaging and communications in medicine (DICOM) files with standard tessellation language (STL) files is performed using the virtual planning software program permitting the creation of a VDP. The smiling scan is an effective, easy to use, and low-cost technique to develop a more comprehensive and simplified facially driven computer-assisted treatment plan, allowing a prosthetically driven implant placement and the delivery of an immediate computer aided design (CAD) computer aided manufacturing (CAM) temporary fixed dental prostheses (CAD/CAM technology). Copyright © 2018 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  15. [Virtual reality in video-assisted thoracoscopic lung segmentectomy].

    PubMed

    Onuki, Takamasa

    2009-07-01

    The branching patterns of pulmonary arteries and veins vary greatly in the pulmonary hilar region and are very complicated. We attempted to reconstruct anatomically correct images using a freeware program. After uploading the images to a personal computer, bronchi, pulmonary arteries and veins were traced by moving up and down in the images and the location and thickness of the bronchi and pulmonary vasculture were indicated as different-sized cylinders. Next, based on the resulting numerical data, a 3D image was reconstructed using Metasequoia shareware. The reconstructed images can be manipulated by virtual surgical procedures such as reshaping, cutting and moving. These system would be very helpful in complicated video-assisted thoracic surgery such as lung segmentectomy.

  16. Improved accuracy of component alignment with the implementation of image-free navigation in total knee arthroplasty.

    PubMed

    Rosenberger, Ralf E; Hoser, Christian; Quirbach, Sebastian; Attal, Rene; Hennerbichler, Alfred; Fink, Christian

    2008-03-01

    Accuracy of implant positioning and reconstruction of the mechanical leg axis are major requirements for achieving good long-term results in total knee arthroplasty (TKA). The purpose of the present study was to determine whether image-free computer navigation technology has the potential to improve the accuracy of component alignment in TKA cohorts of experienced surgeons immediately and constantly. One hundred patients with primary arthritis of the knee underwent the unilateral total knee arthroplasty. The cohort of 50 TKAs implanted with conventional instrumentation was directly followed by the cohort of the very first 50 computer-assisted TKAs. All surgeries were performed by two senior surgeons. All patients received the Zimmer NexGen total knee prosthesis (Zimmer Inc., Warsaw, IN, USA). There was no variability regarding surgeons or surgical technique, except for the use of the navigation system (StealthStation) Treon plus Medtronic Inc., Minnesota, MI, USA). Accuracy of implant positioning was measured on postoperative long-leg standing radiographs and standard lateral X-rays with regard to the valgus angle and the coronal and sagittal component angles. In addition, preoperative deformities of the mechanical leg axis, tourniquet time, age, and gender were correlated. Statistical analyses were performed using the SPSS 15.0 (SPSS Inc., Chicago, IL, USA) software package. Independent t-tests were used, with significance set at P < 0.05 (two-tailed) to compare differences in mean angular values and frontal mechanical alignment between the two cohorts. To compute the rate of optimally implanted prostheses between the two groups we used the chi(2) test. The average postoperative radiological frontal mechanical alignment was 1.88 degrees of varus (range 6.1 degrees of valgus-10.1 degrees of varus; SD 3.68 degrees ) in the conventional cohort and 0.28 degrees of varus (range 3.7 degrees -6.0 degrees of varus; SD 1.97 degrees ) in the navigated cohort. Including all criteria for optimal implant alignment, 16 cases (32%) in the conventional cohort and 31 cases (62%) in the navigated cohort have been implanted optimally. The average difference in tourniquet time was modest with additional 12.9 min in the navigated cohort compared to the conventional cohort. Our findings suggest that the experienced knee surgeons can improve immediately and constantly the accuracy of component orientation using an image-free computer-assisted navigation system in TKA. The computer-assisted technology has shown to be easy to use, safe, and efficient in routine knee replacement surgery. We believe that navigation is a key technology for various current and future surgical alignment topics and minimal-invasive lower limb surgery.

  17. Surgical robotics beyond enhanced dexterity instrumentation: a survey of machine learning techniques and their role in intelligent and autonomous surgical actions.

    PubMed

    Kassahun, Yohannes; Yu, Bingbin; Tibebu, Abraham Temesgen; Stoyanov, Danail; Giannarou, Stamatia; Metzen, Jan Hendrik; Vander Poorten, Emmanuel

    2016-04-01

    Advances in technology and computing play an increasingly important role in the evolution of modern surgical techniques and paradigms. This article reviews the current role of machine learning (ML) techniques in the context of surgery with a focus on surgical robotics (SR). Also, we provide a perspective on the future possibilities for enhancing the effectiveness of procedures by integrating ML in the operating room. The review is focused on ML techniques directly applied to surgery, surgical robotics, surgical training and assessment. The widespread use of ML methods in diagnosis and medical image computing is beyond the scope of the review. Searches were performed on PubMed and IEEE Explore using combinations of keywords: ML, surgery, robotics, surgical and medical robotics, skill learning, skill analysis and learning to perceive. Studies making use of ML methods in the context of surgery are increasingly being reported. In particular, there is an increasing interest in using ML for developing tools to understand and model surgical skill and competence or to extract surgical workflow. Many researchers begin to integrate this understanding into the control of recent surgical robots and devices. ML is an expanding field. It is popular as it allows efficient processing of vast amounts of data for interpreting and real-time decision making. Already widely used in imaging and diagnosis, it is believed that ML will also play an important role in surgery and interventional treatments. In particular, ML could become a game changer into the conception of cognitive surgical robots. Such robots endowed with cognitive skills would assist the surgical team also on a cognitive level, such as possibly lowering the mental load of the team. For example, ML could help extracting surgical skill, learned through demonstration by human experts, and could transfer this to robotic skills. Such intelligent surgical assistance would significantly surpass the state of the art in surgical robotics. Current devices possess no intelligence whatsoever and are merely advanced and expensive instruments.

  18. Application of virtual surgical planning with computer assisted design and manufacturing technology to cranio-maxillofacial surgery.

    PubMed

    Zhao, Linping; Patel, Pravin K; Cohen, Mimis

    2012-07-01

    Computer aided design and manufacturing (CAD/CAM) technology today is the standard in manufacturing industry. The application of the CAD/CAM technology, together with the emerging 3D medical images based virtual surgical planning (VSP) technology, to craniomaxillofacial reconstruction has been gaining increasing attention to reconstructive surgeons. This article illustrates the components, system and clinical management of the VSP and CAD/CAM technology including: data acquisition, virtual surgical and treatment planning, individual implant design and fabrication, and outcome assessment. It focuses primarily on the technical aspects of the VSP and CAD/CAM system to improve the predictability of the planning and outcome.

  19. Outcomes in patients undergoing robotic reconstructive uterovaginal anastomosis of congenital cervical and vaginal atresia.

    PubMed

    Zhang, Ying; Chen, Yisong; Hua, Keqin

    2017-09-01

    To introduce our experience of robotic surgery of reconstructive uterovaginal anastomosis and operative outcomes in congenital cervical and vaginal atresia patients. Clinical observation and follow-up of four patients with congenital cervical and vaginal atresia who underwent robotic reconstruction of cervix and vagina by SIS (small intestinal submucosa, SIS) graft. Average patient age was 13.8 ± 2.2. Patients complained of severe periodic abdominal pain. Diagnosis was made according to clinical characteristics, physical examination, MRI and classified by ESHRE/ESGE system. All patients underwent reconstruction of cervix and vagina by uterovaginal anastomosis by SIS graft. Average operation time was 232.5 ± 89.2 min, average blood loss was 225.0 ± 95.7 mL. After surgery, all patients have regular menstruation without pain. Average follow up was 12 months, average vagina length was 8.9 ± 0.3 cm, average vagina width was 2.9 ± 0.1 cm. Robotic assisted reconstruction of cervix and vagina is feasible from our experience, enlarged cases and additional studies are required. © 2017 The Authors The International Journal of Medical Robotics and Computer Assisted Surgery Published by John Wiley & Sons Ltd.

  20. Robot-assisted pancreatic surgery: a systematic review of the literature.

    PubMed

    Strijker, Marin; van Santvoort, Hjalmar C; Besselink, Marc G; van Hillegersberg, Richard; Borel Rinkes, Inne H M; Vriens, Menno R; Molenaar, I Quintus

    2013-01-01

    To potentially improve outcomes in pancreatic resection, robot-assisted pancreatic surgery has been introduced. This technique has possible advantages over laparoscopic surgery, such as its affordance of three-dimensional vision and increased freedom of movement of instruments. A systematic review was performed to assess the safety and feasibility of robot-assisted pancreatic surgery. The literature published up to 30 September 2011 was systematically reviewed, with no restrictions on publication date. Studies reporting on over five patients were included. Animal studies, studies not reporting morbidity and mortality, review articles and conference abstracts were excluded. Data were extracted and weighted means were calculated. A total of 499 studies were screened, after which eight cohort studies reporting on a total of 251 patients undergoing robot-assisted pancreatic surgery were retained for analysis. Weighted mean operation time was 404 ± 102 min (510 ± 107 min for pancreatoduodenectomy only). The rate of conversion was 11.0% (16.4% for pancreatoduodenectomy only). Overall morbidity was 30.7% (n = 77), most frequently involving pancreatic fistulae (n = 46). Mortality was 1.6%. Negative surgical margins were obtained in 92.9% of patients. The rate of spleen preservation in distal pancreatectomy was 87.1%. Robot-assisted pancreatic surgery seems to be safe and feasible in selected patients and, in left-sided resections, may increase the rate of spleen preservation. Randomized studies should compare the respective outcomes of robot-assisted, laparoscopic and open pancreatic surgery. © 2012 International Hepato-Pancreato-Biliary Association.

  1. Robot-assisted pancreatic surgery: a systematic review of the literature

    PubMed Central

    Strijker, Marin; van Santvoort, Hjalmar C; Besselink, Marc G; van Hillegersberg, Richard; Borel Rinkes, Inne HM; Vriens, Menno R; Molenaar, I Quintus

    2013-01-01

    Background To potentially improve outcomes in pancreatic resection, robot-assisted pancreatic surgery has been introduced. This technique has possible advantages over laparoscopic surgery, such as its affordance of three-dimensional vision and increased freedom of movement of instruments. A systematic review was performed to assess the safety and feasibility of robot-assisted pancreatic surgery. Methods The literature published up to 30 September 2011 was systematically reviewed, with no restrictions on publication date. Studies reporting on over five patients were included. Animal studies, studies not reporting morbidity and mortality, review articles and conference abstracts were excluded. Data were extracted and weighted means were calculated. Results A total of 499 studies were screened, after which eight cohort studies reporting on a total of 251 patients undergoing robot-assisted pancreatic surgery were retained for analysis. Weighted mean operation time was 404 ± 102 min (510 ± 107 min for pancreatoduodenectomy only). The rate of conversion was 11.0% (16.4% for pancreatoduodenectomy only). Overall morbidity was 30.7% (n = 77), most frequently involving pancreatic fistulae (n = 46). Mortality was 1.6%. Negative surgical margins were obtained in 92.9% of patients. The rate of spleen preservation in distal pancreatectomy was 87.1%. Conclusions Robot-assisted pancreatic surgery seems to be safe and feasible in selected patients and, in left-sided resections, may increase the rate of spleen preservation. Randomized studies should compare the respective outcomes of robot-assisted, laparoscopic and open pancreatic surgery. PMID:23216773

  2. Current perspectives in robotic assisted surgery.

    PubMed

    Binet, Aurélien; Ballouhey, Quentin; Chaussy, Yann; de Lambert, Guénolée; Braïk, Karim; Villemagne, Thierry; Becmeur, François; Fourcade, Laurent; Lardy, Hubert

    2018-02-23

    From classical surgery to Robotic Assisted Surgery, there is a long way allowed by Minimal Invasive Surgery' improvements. The last three decades have witnessed a prodigious development of minimally invasive surgery (MIS) and especially in the field of laparoscopic pediatric surgery but there are several limitations in the use of conventional laparoscopic surgery and Robotic Assisted Surgery was developed to relieve these drawbacks. This new technology enables today the performance of a wide variety of procedures in children with a minimally invasive approach. As for all new technologies, an objective evaluation is essential with the need to respond to several questions: Is the technology feasible? Is the technology safe? Is the technology efficient? Does it bring about benefits compared with current technology? What are the procedures derived from most benefits of robotic assistance? How to assume the transition from open surgery to Minimal Invasive access for RAS? In the first part of this article, the authors give details about technical concerns and then describe the implementation process with its organization, pitfalls, successes, and issues from human resources and financial standpoints. The learning curve is then described and a special focus on small children weighing less than 15 Kg is developed. Finally, the concept of evaluation of this emerging technology is evocated and financial concerns are developed.

  3. Laparoscopy vs robotics in surgical management of endometrial cancer: comparison of intraoperative and postoperative complications.

    PubMed

    Seror, Julien; Bats, Anne-Sophie; Huchon, Cyrille; Bensaïd, Chérazade; Douay-Hauser, Nathalie; Lécuru, Fabrice

    2014-01-01

    To compare the rates of intraoperative and postoperative complications of robotic surgery and laparoscopy in the surgical treatment of endometrial cancer. Unicentric retrospective study (Canadian Task Force classification II-2). Tertiary teaching hospital. The study was performed from January 2002 to December 2011 and included patients with endometrial cancer who underwent laparoscopic or robotically assisted laparoscopic surgical treatment. Data collected included preoperative data, tumor characteristics, intraoperative data (route of surgery, surgical procedures, and complications), and postoperative data (early and late complications according to the Clavien-Dindo classification, and length of hospital stay). Morbidity was compared between the 2 groups. The study included 146 patients, of whom 106 underwent laparoscopy and 40 underwent robotically assisted surgery. The 2 groups were comparable in terms of demographic and preoperative data. Intraoperative complications occurred in 9.4% of patients who underwent laparoscopy and in none who underwent robotically assisted surgery (p = .06). There was no difference between the 2 groups in terms of postoperative events. Robotically assisted surgery is not associated with a significant difference in intraoperative and postoperative complications, even when there were no intraoperative complications of robotically assisted surgery. Copyright © 2014 AAGL. Published by Elsevier Inc. All rights reserved.

  4. Uniportal video-assisted thoracic surgery course in Mexico-first experience.

    PubMed

    Céspedes-Meneses, Erick; Echavarri-Arana, José Manuel; Tort-Martínez, Alejandro; Guzmán-de Alba, Enrique; das Neves-Pereira, Joao Carlos; González-Rivas, Diego

    2016-01-01

    "The First Minimally Invasive Thoracic Surgery Uniportal Course" in Mexico was held from July 13 th to 15 th in Mexico City, at the National Institute of Respiratory Diseases (INER). Thoracic surgeons from around Mexico assisted the course. The special guests were the Spanish doctor Diego González-Rivas and the Brasilian doctor Joao Carlos das Neves-Pereira. The course included live surgery and wet lab. Demonstration of the uniportal video-assisted thoracic surgery (VATS) technique was done. The course was a success and Mexican thoracic surgeons were ready to adopt this technique.

  5. The decisive role of the patient-side surgeon in robotic surgery.

    PubMed

    Sgarbura, Olivia; Vasilescu, Catalin

    2010-12-01

    Minimally invasive technology literature is mainly concerned about the feasibility of the robotic procedures and the performance of the console surgeon. However, few of these technologies could be applied without a well-trained team. Our goal was to demonstrate that robotic surgery depends more on the patient-side assistant surgeon's abilities than has been previously reported. In our department, 280 interventions in digestive, thoracic, and gynecological surgery were performed since the acquisition of the robotic equipment. There are three teams trained in robotic surgery with three console surgeons and four certified patient-side surgeons. Four more patient-side assistants were trained at our center. Trocar placement, docking and undocking of the robot, insertion of the laparoscopic instruments, and hemostatic maneuvers with various devices were quantified and compared. Assistants trained by using animal or cadaver surgery are more comfortable with the robotic instruments handling and with docking and undocking of the robot. Assistants who finalized their residency or attend their final year are more accurate with the insertion of the laparoscopic instrument to the targeted organ and more skillful with LigaSure or clip applier devices. Interventions that require vivid participation of the assistants have shorter assistant-depending time intervals at the end of the learning curve than at the beginning. Robotic surgery is a team effort and is greatly dependant on the performance of assistant surgeons. Interventions that have the benefit of a trained team are more rapid and secure.

  6. Da Vinci Xi Robot-Assisted Penetrating Keratoplasty.

    PubMed

    Chammas, Jimmy; Sauer, Arnaud; Pizzuto, Joëlle; Pouthier, Fabienne; Gaucher, David; Marescaux, Jacques; Mutter, Didier; Bourcier, Tristan

    2017-06-01

    This study aims (1) to investigate the feasibility of robot-assisted penetrating keratoplasty (PK) using the new Da Vinci Xi Surgical System and (2) to report what we believe to be the first use of this system in experimental eye surgery. Robot-assisted PK procedures were performed on human corneal transplants using the Da Vinci Xi Surgical System. After an 8-mm corneal trephination, four interrupted sutures and one 10.0 monofilament running suture were made. For each procedure, duration and successful completion of the surgery as well as any unexpected events were assessed. The depth of the corneal sutures was checked postoperatively using spectral-domain optical coherence tomography (SD-OCT). Robot-assisted PK was successfully performed on 12 corneas. The Da Vinci Xi Surgical System provided the necessary dexterity to perform the different steps of surgery. The mean duration of the procedures was 43.4 ± 8.9 minutes (range: 28.5-61.1 minutes). There were no unexpected intraoperative events. SD-OCT confirmed that the sutures were placed at the appropriate depth. We confirm the feasibility of robot-assisted PK with the new Da Vinci Surgical System and report the first use of the Xi model in experimental eye surgery. Operative time of robot-assisted PK surgery is now close to that of conventional manual surgery due to both improvement of the optical system and the presence of microsurgical instruments. Experimentations will allow the advantages of robot-assisted microsurgery to be identified while underlining the improvements and innovations necessary for clinical use.

  7. Effect of a multimedia-assisted informed consent procedure on the information gain, satisfaction, and anxiety of cataract surgery patients.

    PubMed

    Tipotsch-Maca, Saskia M; Varsits, Ralph M; Ginzel, Christian; Vecsei-Marlovits, Pia V

    2016-01-01

    To assess whether a multimedia-assisted preoperative informed consent procedure has an effect on patients' knowledge concerning cataract surgery, satisfaction with the informed consent process, and reduction in anxiety levels. Hietzing Hospital, Vienna, Austria. Prospective randomized controlled clinical trial. Patients participated in an informed consent procedure for age-related cataract surgery that included the standard approach only (reading the information brochure and having a standardized face-to-face discussion) or supplemented with a computer-animated video. The main outcome was information retention assessed by a questionnaire. Further outcome measures used were the State-Trait Anxiety Inventory, the Visual Function-14 score, and an assessment of satisfaction. The study included 123 patients (64 in standard-only group; 59 in computer-animated video group). Both groups scored well on the questionnaire; however, patients who watched the video performed better (82% retention versus 72%) (P = .002). Scores tended to decrease with increasing age (r = -0.25, P = .005); however, this decrease was smaller in the group that watched the video. Both groups had elevated anxiety levels (means in video group: anxiety concerning the current situation [S-anxiety] = 63.8 ± 9.6 [SD], general tendency toward anxiety [T-anxiety] = 65.5 ± 7.9; means in control group: S-anxiety = 61.9 ± 10.3, T-anxiety = 66.2 ± 7.8). A high level of information retention was achieved using an informed consent procedure consisting of an information brochure and a standardized face-to-face discussion. A further increase in information retention was achieved, even with increasing patient age, by adding a multimedia presentation. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2016 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  8. Clinical applicability of robot-guided contact-free laser osteotomy in cranio-maxillo-facial surgery: in-vitro simulation and in-vivo surgery in minipig mandibles.

    PubMed

    Baek, K-W; Deibel, W; Marinov, D; Griessen, M; Bruno, A; Zeilhofer, H-F; Cattin, Ph; Juergens, Ph

    2015-12-01

    Laser was being used in medicine soon after its invention. However, it has been possible to excise hard tissue with lasers only recently, and the Er:YAG laser is now established in the treatment of damaged teeth. Recently experimental studies have investigated its use in bone surgery, where its major advantages are freedom of cutting geometry and precision. However, these advantages become apparent only when the system is used with robotic guidance. The main challenge is ergonomic integration of the laser and the robot, otherwise the surgeon's space in the operating theatre is obstructed during the procedure. Here we present our first experiences with an integrated, miniaturised laser system guided by a surgical robot. An Er:YAG laser source and the corresponding optical system were integrated into a composite casing that was mounted on a surgical robotic arm. The robot-guided laser system was connected to a computer-assisted preoperative planning and intraoperative navigation system, and the laser osteotome was used in an operating theatre to create defects of different shapes in the mandibles of 6 minipigs. Similar defects were created on the opposite side with a piezoelectric (PZE) osteotome and a conventional drill guided by a surgeon. The performance was analysed from the points of view of the workflow, ergonomics, ease of use, and safety features. The integrated robot-guided laser osteotome can be ergonomically used in the operating theatre. The computer-assisted and robot-guided laser osteotome is likely to be suitable for clinical use for ostectomies that require considerable accuracy and individual shape. Copyright © 2015 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  9. Comparison of carbon dioxide laser-assisted versus stapler-assisted endoscopic cricopharyngeal myotomy.

    PubMed

    Pollei, Taylor R; Hinni, Michael L; Hayden, Richard E; Lott, David G; Mors, Matthew B

    2013-09-01

    We directly compared endoscopic carbon dioxide (CO2) laser and stapler treatment methods for both cricopharyngeal hypertrophy (CPH) and Zenker's diverticulum (ZD). We performed a single-institution retrospective chart review of 153 patients who underwent either CO2 laser-assisted or stapler-assisted endoscopic cricopharyngeal myotomy (CPM). Isolated CPH was more likely to be treated with the CO2 laser than by stapler techniques. The ZD pouch size decreased significantly after surgery in both laser (p = 0.04) and stapler (p = 0.008) groups. The average duration of the procedure for CPM was longer for the laser than for the stapler (p = 0.01). Both techniques were successful when used in revision procedures. The overall complication rates were not statistically significantly different. Laser surgery trended toward a higher rate of major complications (2.4% versus 0%). Symptomatic recurrence was more likely after stapler surgery (p = 0.002). The rates of revision surgery were similar in the two groups (3.3% for laser and 4.3% for stapler). In the treatment of isolated CPH or ZD, stapler-assisted endoscopic surgery results in a shorter operative time, whereas laser-assisted CPM results in a decreased incidence of symptomatic recurrence.

  10. Computer-assisted surgery simulations and directed practice of total knee arthroplasty: educational benefits to the trainee.

    PubMed

    Myden, C A; Anglin, C; Kopp, G D; Hutchison, C R

    2012-01-01

    Orthopaedic residents typically learn to perform total knee arthroplasty (TKA) through an apprenticeship-type model, which is a necessarily slow process. Surgical skills courses, using artificial bones, have been shown to improve technical and cognitive skills significantly within a couple of days. The addition of computer-assisted surgery (CAS) simulations challenges the participants to consider the same task in a different context, promoting cognitive flexibility. We designed a hands-on educational intervention for junior residents with a conventional tibiofemoral TKA station, two different tibiofemoral CAS stations, and a CAS and conventional patellar resection station, including both qualitative and quantitative analyses. Qualitatively, structured interviews before and after the course were analyzed for recurring themes. Quantitatively, subjects were evaluated on their technical skills before and after the course, and on a multiple-choice knowledge test and error detection test after the course, in comparison to senior residents who performed only the testing. Four themes emerged: confidence, awareness, deepening knowledge and changed perspectives. The residents' attitudes to CAS changed from negative before the course to neutral or positive afterwards. The junior resident group completed 23% of tasks in the pre-course skills test and 75% of tasks on the post-test (p<0.01), compared to 45% of tasks completed by the senior resident group. High-impact educational interventions, promoting cognitive flexibility, would benefit trainees, attending surgeons, the healthcare system and patients.

  11. The place of robotics in gynecologic surgery.

    PubMed

    Quemener, J; Boulanger, L; Rubod, C; Cosson, M; Vinatier, D; Collinet, P

    2012-10-01

    Robot-assisted laparoscopic gynecologic surgery has undergone widespread development in recent years. The surgical literature on this subject continues to grow. The goal of this article is to summarize the principal indications for robotic assistance in gynecologic surgery and to offer a general overview of the principal articles dealing with robotic surgery for both benign and malignant disease. Copyright © 2012 Elsevier Masson SAS. All rights reserved.

  12. A Case Series of Rapid Prototyping and Intraoperative Imaging in Orbital Reconstruction

    PubMed Central

    Lim, Christopher G.T.; Campbell, Duncan I.; Cook, Nicholas; Erasmus, Jason

    2014-01-01

    In Christchurch Hospital, rapid prototyping (RP) and intraoperative imaging are the standard of care in orbital trauma and has been used since February 2013. RP allows the fabrication of an anatomical model to visualize complex anatomical structures which is dimensionally accurate and cost effective. This assists diagnosis, planning, and preoperative implant adaptation for orbital reconstruction. Intraoperative imaging involves a computed tomography scan during surgery to evaluate surgical implants and restored anatomy and allows the clinician to correct errors in implant positioning that may occur during the same procedure. This article aims to demonstrate the potential clinical and cost saving benefits when both these technologies are used in orbital reconstruction which minimize the need for revision surgery. PMID:26000080

  13. A case series of rapid prototyping and intraoperative imaging in orbital reconstruction.

    PubMed

    Lim, Christopher G T; Campbell, Duncan I; Cook, Nicholas; Erasmus, Jason

    2015-06-01

    In Christchurch Hospital, rapid prototyping (RP) and intraoperative imaging are the standard of care in orbital trauma and has been used since February 2013. RP allows the fabrication of an anatomical model to visualize complex anatomical structures which is dimensionally accurate and cost effective. This assists diagnosis, planning, and preoperative implant adaptation for orbital reconstruction. Intraoperative imaging involves a computed tomography scan during surgery to evaluate surgical implants and restored anatomy and allows the clinician to correct errors in implant positioning that may occur during the same procedure. This article aims to demonstrate the potential clinical and cost saving benefits when both these technologies are used in orbital reconstruction which minimize the need for revision surgery.

  14. Robotic versus laparoscopic proctectomy for rectal cancer: a meta-analysis.

    PubMed

    Memon, Sameer; Heriot, Alexander G; Murphy, Declan G; Bressel, Mathias; Lynch, A Craig

    2012-07-01

    Robot-assisted laparoscopic surgery is being performed more frequently for the minimally invasive management of rectal cancer. The objective of this meta-analysis was to compare the clinical and oncologic safety and efficacy of robot-assisted versus conventional laparoscopic surgery. A search of the Medline and Embase databases was performed for studies that compared clinical or oncologic outcomes of conventional laparoscopic proctectomy with robot-assisted laparoscopic proctectomy for rectal cancer. The methodological quality of the selected studies was critically assessed to identify studies suitable for inclusion. Meta-analysis was performed by a random effects model and analyzed by Review Manager. Clinical outcomes evaluated were conversion rates, operation times, length of hospital stay, and complications. Oncologic outcomes evaluated were circumferential margin status, number of lymph nodes collected, and distal resection margin lengths. Eight comparative studies were assessed for quality, and seven studies were included in the meta-analysis. Two studies were matched case-control studies, and five were unmatched. A total of 353 robot-assisted laparoscopic surgery proctectomy cases and 401 conventional laparoscopic surgery proctectomy cases were analyzed. Robotic surgery was associated with a significantly lower conversion rate (P=0.03; 95% confidence interval 1-12). There was no difference in complications, circumferential margin involvement, distal resection margin, lymph node yield, or hospital stay (P=NS). Robot-assisted surgery decreased the conversion rate compared to conventional laparoscopic surgery. Other clinical outcomes and oncologic outcomes were equivalent. The benefits of robotic rectal cancer surgery may differ between population groups.

  15. A multimedia electronic patient record (ePR) system for image-assisted minimally invasive spinal surgery.

    PubMed

    Documet, Jorge; Le, Anh; Liu, Brent; Chiu, John; Huang, H K

    2010-05-01

    This paper presents the concept of bridging the gap between diagnostic images and image-assisted surgical treatment through the development of a one-stop multimedia electronic patient record (ePR) system that manages and distributes the real-time multimodality imaging and informatics data that assists the surgeon during all clinical phases of the operation from planning Intra-Op to post-care follow-up. We present the concept of this multimedia ePR for surgery by first focusing on image-assisted minimally invasive spinal surgery as a clinical application. Three clinical phases of minimally invasive spinal surgery workflow in Pre-Op, Intra-Op, and Post-Op are discussed. The ePR architecture was developed based on the three-phased workflow, which includes the Pre-Op, Intra-Op, and Post-Op modules and four components comprising of the input integration unit, fault-tolerant gateway server, fault-tolerant ePR server, and the visualization and display. A prototype was built and deployed to a minimally invasive spinal surgery clinical site with user training and support for daily use. A step-by-step approach was introduced to develop a multimedia ePR system for imaging-assisted minimally invasive spinal surgery that includes images, clinical forms, waveforms, and textual data for planning the surgery, two real-time imaging techniques (digital fluoroscopic, DF) and endoscope video images (Endo), and more than half a dozen live vital signs of the patient during surgery. Clinical implementation experiences and challenges were also discussed.

  16. From Leonardo to da Vinci: the history of robot-assisted surgery in urology.

    PubMed

    Yates, David R; Vaessen, Christophe; Roupret, Morgan

    2011-12-01

    What's known on the subject? and What does the study add? Numerous urological procedures can now be performed with robotic assistance. Though not definitely proven to be superior to conventional laparoscopy or traditional open surgery in the setting of a randomised trial, in experienced centres robot-assisted surgery allows for excellent surgical outcomes and is a valuable tool to augment modern surgical practice. Our review highlights the depth of history that underpins the robotic surgical platform we utilise today, whilst also detailing the current place of robot-assisted surgery in urology in 2011. The evolution of robots in general and as platforms to augment surgical practice is an intriguing story that spans cultures, continents and centuries. A timeline from Yan Shi (1023-957 bc), Archytas of Tarentum (400 bc), Aristotle (322 bc), Heron of Alexandria (10-70 ad), Leonardo da Vinci (1495), the Industrial Revolution (1790), 'telepresence' (1950) and to the da Vinci(®) Surgical System (1999), shows the incredible depth of history and development that underpins the modern surgical robot we use to treat our patients. Robot-assisted surgery is now well-established in Urology and although not currently regarded as a 'gold standard' approach for any urological procedure, it is being increasingly used for index operations of the prostate, kidney and bladder. We perceive that robotic evolution will continue infinitely, securing the place of robots in the history of Urological surgery. Herein, we detail the history of robots in general, in surgery and in Urology, highlighting the current place of robot-assisted surgery in radical prostatectomy, partial nephrectomy, pyeloplasty and radical cystectomy. © 2011 THE AUTHORS. BJU INTERNATIONAL © 2011 BJU INTERNATIONAL.

  17. The dawn of computer-assisted robotic osteotomy with ytterbium-doped fiber laser.

    PubMed

    Sotsuka, Yohei; Nishimoto, Soh; Tsumano, Tomoko; Kawai, Kenichiro; Ishise, Hisako; Kakibuchi, Masao; Shimokita, Ryo; Yamauchi, Taisuke; Okihara, Shin-ichiro

    2014-05-01

    Currently, laser radiation is used routinely in medical applications. For infrared lasers, bone ablation and the healing process have been reported, but no laser systems are established and applied in clinical bone surgery. Furthermore, industrial laser applications utilize computer and robot assistance; medical laser radiations are still mostly conducted manually nowadays. The purpose of this study was to compare the histological appearance of bone ablation and healing response in rabbit radial bone osteotomy created by surgical saw and ytterbium-doped fiber laser controlled by a computer with use of nitrogen surface cooling spray. An Ytterbium (Yb)-doped fiber laser at a wavelength of 1,070 nm was guided by a computer-aided robotic system, with a spot size of 100 μm at a distance of approximately 80 mm from the surface. The output power of the laser was 60 W at the scanning speed of 20 mm/s scan using continuous wave system with nitrogen spray level 0.5 MPa (energy density, 3.8 × 10(4) W/cm(2)). Rabbits radial bone osteotomy was performed by an Yb-doped fiber laser and a surgical saw. Additionally, histological analyses of the osteotomy site were performed on day 0 and day 21. Yb-doped fiber laser osteotomy revealed a remarkable cutting efficiency. There were little signs of tissue damage to the muscle. Lased specimens have shown no delayed healing compared with the saw osteotomies. Computer-assisted robotic osteotomy with Yb-doped fiber laser was able to perform. In rabbit model, laser-induced osteotomy defects, compared to those by surgical saw, exhibited no delayed healing response.

  18. Analgesic efficacy of lidocaine for suction-assisted lipectomy with tumescent technique under general anesthesia: a randomized, double-masked, controlled trial.

    PubMed

    Danilla, Stefan; Fontbona, Montserrat; de Valdés, Victoria Diaz; Dagnino, Bruno; Sorolla, Juan Pablo; Israel, Guillermo; Searle, Susana; Norambuena, Hernán; Cabello, Rodrigo

    2013-08-01

    Suction-assisted lipectomy is one of the most common procedures performed in plastic surgery. To minimize blood loss and to obtain adequate analgesia, a liquid solution is infiltrated into the subcutaneous plane before suction. The objective of this study was to determine whether the use of lidocaine in the infiltration solution reduces postoperative pain. A prospective, randomized, double-masked, clinical trial was designed. Each side of patients' body zones to be treated with suction-assisted lipectomy was randomized to receive infiltration solution with or without lidocaine. Treatment allocation was performed using computer-generated random numbers in permuted blocks of eight. Pain was assessed using the visual analogue scale and registered 1, 6, 12, 18, and 24 hours after the procedure. The trial was stopped after a first interim analysis. The use of lidocaine in the dilute solution reduced pain by 0.5 point on the visual analogue scale (95 percent CI, 0.3 to 0.8; p<0.001). The effect was independent of the suctioned body zone (p=0.756), and lasted until 18 hours after surgery. Its analgesic effect was lost at the 24-hour postoperative control. Pain increased an average of 0.018 point on the visual analogue scale per hour (95 percent CI, 0.001 to 0.036; p=0.043). The use of lidocaine in the infiltration solution is effective in postoperative pain control until 18 hours after surgery. Nevertheless, its clinical effect is limited and clinically irrelevant, and therefore it is no longer used by the authors. Therapeutic, I.

  19. Robotic bariatric surgery: A general review of the current status.

    PubMed

    Jung, Minoa K; Hagen, Monika E; Buchs, Nicolas C; Buehler, Leo H; Morel, Philippe

    2017-12-01

    While conventional laparoscopy is the gold standard for almost all bariatric procedures, robotic assistance holds promise for facilitating complex surgeries and improving clinical outcomes. Since the report of the first robotic-assisted bariatric procedure in 1999, numerous publications, including those reporting comparative trials and meta-analyses across bariatric procedures with a focus on robotic assistance, can be found. This article reviews the current literature and portrays the perspectives of robotic bariatric surgery. While there are substantial reports on robotic bariatric surgery currently in publication, most studies suffer from low levels of evidence. As such, although robotics technology is without a doubt superior to conventional laparoscopy, the precise role of robotics in bariatric surgery is not yet clear. Copyright © 2017 John Wiley & Sons, Ltd.

  20. The Evolution of Computer-Assisted Total Hip Arthroplasty and Relevant Applications

    PubMed Central

    Kim, In-Sung; Bhardwaj, Atul M.; Badami, Ramachandra N.

    2017-01-01

    In total hip arthroplasty (THA), the accurate positioning of implants is the key to achieve a good clinical outcome. Computer-assisted orthopaedic surgery (CAOS) has been developed for more accurate positioning of implants during the THA. There are passive, semi-active, and active systems in CAOS for THA. Navigation is a passive system that only provides information and guidance to the surgeon. There are 3 types of navigation: imageless navigation, computed tomography (CT)-based navigation, and fluoroscopy-based navigation. In imageless navigation system, a new method of registration without the need to register the anterior pelvic plane was introduced. CT-based navigation can be efficiently used for pelvic plane reference, the functional pelvic plane in supine which adjusts anterior pelvic plane sagittal tilt for targeting the cup orientation. Robot-assisted system can be either active or semi-active. The active robotic system performs the preparation for implant positioning as programmed preoperatively. It has been used for only femoral implant cavity preparation. Recently, program for cup positioning was additionally developed. Alternatively, for ease of surgeon acceptance, semi-active robot systems are developed. It was initially applied only for cup positioning. However, with the development of enhanced femoral workflows, this system can now be used to position both cup and stem. Though there have been substantial advancements in computer-assisted THA, its use can still be controversial at present due to the steep learning curve, intraoperative technical issues, high cost and etc. However, in the future, CAOS will certainly enable the surgeon to operate more accurately and lead to improved outcomes in THA as the technology continues to evolve rapidly. PMID:28316957

  1. The role of robotic surgical system in the management of vascular disease.

    PubMed

    Lin, Judith C

    2013-10-01

    The evolution of minimally invasive treatment for aneurysms and occlusive disease has led to the development of endovascular, laparoscopic, and robot-assisted techniques. This article reviews the current literature on the clinical use of robotic surgical systems in the treatment of patients with aneurysms and occlusive disease. A MEDLINE search was performed using the keywords "robotic, vascular, AND surgery." All pertinent articles concerning the use of the robotic surgical system on aneurysms and occlusive disease were reviewed. The author's personal experience consisted of a retrospective review of a prospectively maintained confidential database on all procedures performed with the da Vinci(®) surgical system. Several robot-assisted laparoscopic series on the treatment of aortic disease were identified, including review articles of potential clinical applications in hybrid, laparoscopic vascular, and endovascular treatments for vascular patients using robotic technology. The use of computer-enhanced or robotic technology as a sole modality for bypass of occlusive disease and repair of abdominal aortic, splenic, and renal aneurysms was described in case series with satisfactory patient outcomes. Current robotic endovascular technology was also described. Minimally invasive techniques using endovascular, laparoscopic, or robot-assisted technology have revolutionized the treatment of aortoiliac, splanchnic, and renal aneurysms and occlusive disease. However, robot-assisted techniques for aortic disease may involve a learning curve and increased operating times. Although endovascular therapy is preferred because of faster recovery, this preference for improved short-term outcomes will be balanced with the superiority and durability of robot-assisted endoscopic methods as comparable to open surgery. Copyright © 2013 Elsevier Inc. All rights reserved.

  2. System for robot-assisted real-time laparoscopic ultrasound elastography

    NASA Astrophysics Data System (ADS)

    Billings, Seth; Deshmukh, Nishikant; Kang, Hyun Jae; Taylor, Russell; Boctor, Emad M.

    2012-02-01

    Surgical robots provide many advantages for surgery, including minimal invasiveness, precise motion, high dexterity, and crisp stereovision. One limitation of current robotic procedures, compared to open surgery, is the loss of haptic information for such purposes as palpation, which can be very important in minimally invasive tumor resection. Numerous studies have reported the use of real-time ultrasound elastography, in conjunction with conventional B-mode ultrasound, to differentiate malignant from benign lesions. Several groups (including our own) have reported integration of ultrasound with the da Vinci robot, and ultrasound elastography is a very promising image guidance method for robotassisted procedures that will further enable the role of robots in interventions where precise knowledge of sub-surface anatomical features is crucial. We present a novel robot-assisted real-time ultrasound elastography system for minimally invasive robot-assisted interventions. Our system combines a da Vinci surgical robot with a non-clinical experimental software interface, a robotically articulated laparoscopic ultrasound probe, and our GPU-based elastography system. Elasticity and B-mode ultrasound images are displayed as picture-in-picture overlays in the da Vinci console. Our system minimizes dependence on human performance factors by incorporating computer-assisted motion control that automatically generates the tissue palpation required for elastography imaging, while leaving high-level control in the hands of the user. In addition to ensuring consistent strain imaging, the elastography assistance mode avoids the cognitive burden of tedious manual palpation. Preliminary tests of the system with an elasticity phantom demonstrate the ability to differentiate simulated lesions of varied stiffness and to clearly delineate lesion boundaries.

  3. Curriculum Planning for Oral and Maxillofacial Surgery Assistant Program. Final Report.

    ERIC Educational Resources Information Center

    Taylor, Mary Ann

    This project was conducted to develop a curriculum for dental auxiliary training in the dental specialty field of oral and maxillofacial surgery. Research was conducted to identify the major functions performed by an oral surgery assistant and then to organize these functions into an educational program that would provide adequate didactic and…

  4. Da Vinci Xi Robot–Assisted Penetrating Keratoplasty

    PubMed Central

    Chammas, Jimmy; Sauer, Arnaud; Pizzuto, Joëlle; Pouthier, Fabienne; Gaucher, David; Marescaux, Jacques; Mutter, Didier; Bourcier, Tristan

    2017-01-01

    Purpose This study aims (1) to investigate the feasibility of robot-assisted penetrating keratoplasty (PK) using the new Da Vinci Xi Surgical System and (2) to report what we believe to be the first use of this system in experimental eye surgery. Methods Robot-assisted PK procedures were performed on human corneal transplants using the Da Vinci Xi Surgical System. After an 8-mm corneal trephination, four interrupted sutures and one 10.0 monofilament running suture were made. For each procedure, duration and successful completion of the surgery as well as any unexpected events were assessed. The depth of the corneal sutures was checked postoperatively using spectral-domain optical coherence tomography (SD-OCT). Results Robot-assisted PK was successfully performed on 12 corneas. The Da Vinci Xi Surgical System provided the necessary dexterity to perform the different steps of surgery. The mean duration of the procedures was 43.4 ± 8.9 minutes (range: 28.5–61.1 minutes). There were no unexpected intraoperative events. SD-OCT confirmed that the sutures were placed at the appropriate depth. Conclusions We confirm the feasibility of robot-assisted PK with the new Da Vinci Surgical System and report the first use of the Xi model in experimental eye surgery. Operative time of robot-assisted PK surgery is now close to that of conventional manual surgery due to both improvement of the optical system and the presence of microsurgical instruments. Translational Relevance Experimentations will allow the advantages of robot-assisted microsurgery to be identified while underlining the improvements and innovations necessary for clinical use. PMID:28660096

  5. Surgery Videos: MedlinePlus

    MedlinePlus Videos and Cool Tools

    ... 2009) Mitral Valve Prolapse Minimally Invasive Heart Surgery: Robot Assisted Mitral Valve Repair (Baptist Health South Florida, ... Center, Merriam, KS, 05/04/2012) Kidney Cancer Robot Assisted Partial Nephrectomy Using Fluorescence (Shawnee Mission Medical ...

  6. General surgery residents' perception of robot-assisted procedures during surgical training.

    PubMed

    Farivar, Behzad S; Flannagan, Molly; Leitman, I Michael

    2015-01-01

    With the continued expansion of robotically assisted procedures, general surgery residents continue to receive more exposure to this new technology as part of their training. There are currently no guidelines or standardized training requirements for robot-assisted procedures during general surgical residency. The aim of this study was to assess the effect of this new technology on general surgery training from the residents' perspective. An anonymous, national, web-based survey was conducted on residents enrolled in general surgery training in 2013. The survey was sent to 240 Accreditation Council for Graduate Medical Education-approved general surgery training programs. Overall, 64% of the responding residents were men and had an average age of 29 years. Half of the responses were from postgraduate year 1 (PGY1) and PGY2 residents, and the remainder was from the PGY3 level and above. Overall, 50% of the responses were from university training programs, 32% from university-affiliated programs, and 18% from community-based programs. More than 96% of residents noted the availability of the surgical robot system at their training institution. Overall, 63% of residents indicated that they had participated in robotic surgical cases. Most responded that they had assisted in 10 or fewer robotic cases with the most frequent activities being assisting with robotic trocar placement and docking and undocking the robot. Only 18% reported experience with operating the robotic console. More senior residents (PGY3 and above) were involved in robotic cases compared with junior residents (78% vs 48%, p < 0.001). Overall, 60% of residents indicated that they received no prior education or training before their first robotic case. Approximately 64% of residents reported that formal training in robotic surgery was important in residency training and 46% of residents indicated that robotic-assisted cases interfered with resident learning. Only 11% felt that robotic-assisted cases would replace conventional laparoscopic surgery in the future. This study illustrates that although the most residents have a robot at their institution and have participated in robotic surgery cases, very few residents received formal training before participating in a robotic case. Copyright © 2014 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  7. A 26-year-old man with dyspnea and chest pain.

    PubMed

    Mittal, Saurabh; Jain, Akanksha; Arava, Sudheer; Hadda, Vijay; Mohan, Anant; Guleria, Randeep; Madan, Karan

    2017-01-01

    A 26-year-old smoker male presented with a history of sudden onset dyspnea and right-sided chest pain. Chest radiograph revealed large right-sided pneumothorax which was managed with tube thoracostomy. High-resolution computed tomography thorax revealed multiple lung cysts, and for a definite diagnosis, a video-assisted thoracoscopic surgery-guided lung biopsy was performed followed by pleurodesis. This clinicopathologic conference discusses the clinical and radiological differential diagnoses, utility of lung biopsy, and management options for patients with such a clinical presentation.

  8. A 26-year-old man with dyspnea and chest pain

    PubMed Central

    Mittal, Saurabh; Jain, Akanksha; Arava, Sudheer; Hadda, Vijay; Mohan, Anant; Guleria, Randeep; Madan, Karan

    2017-01-01

    A 26-year-old smoker male presented with a history of sudden onset dyspnea and right-sided chest pain. Chest radiograph revealed large right-sided pneumothorax which was managed with tube thoracostomy. High-resolution computed tomography thorax revealed multiple lung cysts, and for a definite diagnosis, a video-assisted thoracoscopic surgery-guided lung biopsy was performed followed by pleurodesis. This clinicopathologic conference discusses the clinical and radiological differential diagnoses, utility of lung biopsy, and management options for patients with such a clinical presentation. PMID:29099006

  9. Erectile Function and Oncologic Outcomes Following Open Retropubic and Robot-assisted Radical Prostatectomy: Results from the LAParoscopic Prostatectomy Robot Open Trial.

    PubMed

    Sooriakumaran, Prasanna; Pini, Giovannalberto; Nyberg, Tommy; Derogar, Maryam; Carlsson, Stefan; Stranne, Johan; Bjartell, Anders; Hugosson, Jonas; Steineck, Gunnar; Wiklund, Peter N

    2018-04-01

    Whether surgeons perform better utilising a robot-assisted laparoscopic technique compared with an open approach during prostate cancer surgery is debatable. To report erectile function and early oncologic outcomes for both surgical modalities, stratified by prostate cancer risk grouping. In a prospective nonrandomised trial, we recruited 2545 men with prostate cancer from seven open (n=753) and seven robot-assisted (n=1792) Swedish centres (2008-2011). Clinometrically-validated questionnaire-based patient-reported erectile function was collected before, 3 mo, 12 mo, and 24 mo after surgery. Surgeon-reported degree of neurovascular-bundle preservation, pathologist-reported positive surgical margin (PSM) rates, and 2-yr prostate-specific antigen-relapse rates were measured. Among 1702 preoperatively potent men, we found enhanced erectile function recovery for low/intermediate-risk patients in the robot-assisted group at 3 mo. For patients with high-risk tumours, point estimates for erectile function recovery at 24 mo favoured the open surgery group. The degree of neurovascular bundle preservation and erectile function recovery were greater correlated for robot-assisted surgery. In pT2 tumours, 10% versus 17% PSM rates were observed for open and robot-assisted surgery, respectively; corresponding rates for pT3 tumours were 48% and 33%. These differences were associated with biochemical recurrence in pT3 but not pT2 disease. The study is limited by its nonrandomised design and relatively short follow-up. Earlier recovery of erectile function in the robot-assisted surgery group in lower-risk patients is counterbalanced by lower PSM rates for open surgeons in organ-confined disease; thus, both open and robotic surgeons need to consider this trade-off when determining the plane of surgical dissection. Robot-assisted surgery also facilitates easier identification of nerve preservation planes during radical prostatectomy as well as wider dissection for pT3 cases. For prostate cancer surgery, an open operation reduces erection problems in high-risk cancers but has higher relapse rates than robotic surgery. Relapse rates appear similar in low/intermediate-risk cancers and the robot appears better at preserving erections in these cases. Copyright © 2017 European Association of Urology. Published by Elsevier B.V. All rights reserved.

  10. Paranasal sinuses and nasopharynx CT and MRI.

    PubMed

    Sievers, K W; Greess, H; Baum, U; Dobritz, M; Lenz, M

    2000-03-01

    Neoplastic disease of the nose, paranasal sinuses, the nasopharynx and the parapharyngeal space requires thorough assessment of location and extent in order to plan appropriate treatment. CT allows the deep soft tissue planes to be evaluated and provides a complement to the physical examination. It is especially helpful in regions involving thin bony structures (paranasal sinuses, orbita); here CT performs better than MRI. MRI possesses many advantages over other imaging modalities caused by its excellent tissue contrast. In evaluating regions involving predominantly soft tissue structures (ec nasopharynx and parapharyngeal space) MRI is superior to CT. The possibility to obtain strictly consecutive volume data sets with spiral CT or 3D MRI offer excellent perspectives to visualize the data via 2D or 3D postprocessing. Because head and neck tumors reside in a complex area, having a 3D model of the anatomical features may assist in the delineation of pathology. Data sets may be transferred directly into computer systems and thus be used in computer assisted surgery.

  11. Preoperative trajectory planning for closed reduction of long-bone diaphyseal fracture using a computer-assisted reduction system.

    PubMed

    Du, Hailong; Hu, Lei; Li, Changsheng; He, Chunqing; Zhang, Lihai; Tang, Peifu

    2015-03-01

    Balancing reduction accuracy with soft-tissue preservation is a challenge in orthopaedics. Computer-assisted orthopaedic surgery (CAOS) can improve accuracy and reduce radiation exposure. However, previous reports have not summarized the fracture patterns to which CAOS has been applied. We used a CAOS system and a stereolithography model to define a new fracture classification. Twenty reduction tests were performed to evaluate the effectiveness of preoperative trajectory planning. Twenty tests ran automatically and smoothly. Only three slight scratches occurred. Seventy-six path points represented displacement deviations of < 2 mm (average < 1 mm) and angulation deviation of < 1.5°. Because of the strength of muscles, mechanical sensors are used to prevent iatrogenic soft-tissue injury. Secondary fractures are prevented mainly through preoperative trajectory planning. Based on our data, a 1 mm gap between the edges of fractures spikes is sufficient to avoid emergency braking from spike interference. Copyright © 2014 John Wiley & Sons, Ltd.

  12. [da Vinci surgical system].

    PubMed

    Watanabe, Gou; Ishikawa, Norihiro

    2014-07-01

    The da Vinci surgical system was developed by Intuitive Surgical Inc. in the United States as an endoscopic surgical device to assist remote control surgeries. In 1998, the Da Vinci system was first used for cardiothoracic procedures. Currently a combination of robot-assisted internal thoracic artery harvest together with coronary artery bypass grafting (CABG) through a mini-incision (ThoraCAB) or totally endoscopic procedures including anastomoses under robotic assistance (TECAB) are being conducted for the treatment of coronary artery diseases. With the recent advances in catheter interventions, hybrid procedures combining catheter intervention with ThoraCAB or TECAB are anticipated in the future.On the other hand, with the decrease in number of coronary artery bypass surgeries, the share of valvular surgeries is expected to increase in the future. Among them, mitral valvuloplasty for mitral regurgitation is anticipated to be conducted mainly by low-invasive procedures, represented by minimally invasive cardiac surgery( MICS) and robot-assisted surgery. Apart from the intrinsic good surgical view, robotic-assisted systems offer additional advantages of the availability of an amplified view and the easy to observe the mitral valve in the physiological position. Thus, robotic surgical surgeries that make complicated procedures easier are expected to accomplish further developments in the future. Furthermore, while the number of surgeries for atrial septal defects has decreased dramatically following the widespread use of Amplatzer septal occluder, robotic surgery may become a good indication for cases in which the Amplatzer device is not indicated. In Japan, clinical trial of the da Vinci robotic system for heart surgeries has been completed. Statutory approval of the da Vinci system for mitral regurgitation and atrial septal defects is anticipated in the next few years.

  13. Systematic review of published studies on safety and efficacy of thoracoscopic and robot-assisted lobectomy for lung cancer.

    PubMed

    Nakamura, Hiroshige

    2014-01-01

    The safety and efficacy of thoracoscopic and robot-assisted lobectomies for primary lung cancer were reviewed in the literature. Thoracoscopic surgery is less invasive compared to thoracotomy, and it has been reported to be superior with regard to the outcome. In addition, the operability of a surgical robot (da Vinci) is favorable and supplements the disadvantages of conventional endoscopic surgery. Robot-assisted lobectomy has been reported to be comparable to thoracoscopic surgery with regard to the safety and efficacy based on analysis of perioperative results and superior with regard to the operability and length of the learning curve. However, a high cost and a long operative time are of concern. Since robot-assisted surgery has been performed only in early cases, the continuation of a comparative investigation may be necessary.

  14. Negative pressure wound therapy-assisted dermatotraction for the closure of large open wounds in a patient with non-clostridial gas gangrene.

    PubMed

    Ishida, Kenichiro; Noborio, Mitsuhiro; Nishimura, Tetsuro; Ieki, Yohei; Shimahara, Yumiko; Sogabe, Taku; Ehara, Naoki; Saoyama, Yuki; Sadamitsu, Daikai

    2016-04-01

    A 53-year-old woman developed septic shock associated with non-clostridial gas gangrene. She presented to the emergency department with two large open wounds on both thighs and in her sacral region. Non-enhanced computed tomography showed air density in contact with the right iliopsoas, which extended to the posterior compartment of the thigh. We made repeated efforts at surgical debridement of the wound with resection of necrotic tissues. Using negative pressure wound therapy-assisted dermatotraction, the pus pockets and the wound dehiscence decreased in size. Using this method we were successful in achieving delayed closure without skin grafts. Negative pressure wound therapy can be an effective treatment for large and infected open contoured wounds. Negative pressure wound therapy-assisted dermatotraction might be beneficial for poorly healing, large, open wounds in patients in poor condition and with insufficient reserve to tolerate reconstructive surgery.

  15. Osseous outgrowth on the buccal maxilla associated with piezosurgery-assisted en-masse retraction: A case series.

    PubMed

    Tunçer, Nilüfer İrem; Arman-Özçırpıcı, Ayça; Oduncuoğlu, Bahar Füsun; Kantarcı, Alpdoğan

    2018-01-01

    Piezoelectric surgery is a novel surgical approach used in orthodontic treatment for rapid tooth movement. This paper presents a case series wherein osseous outgrowths were observed in response to piezosurgery-assisted en-masse retraction. Sixteen patients requiring upper premolar extractions were treated with miniscrew-supported en-masse retraction and received minimally invasive decortication via piezosurgery. Computed tomography (CT) of the maxillary anterior region was performed to investigate the nature of the outgrowths. In 8 of the 16 patients, hemispheric or disc-shaped osseous outgrowths were observed on the sites where piezosurgery was performed during retraction. CT images revealed that these outgrowths were alveolar bone. This case series presents a previously unreported osseous response to piezosurgery-assisted tooth movement during orthodontic treatment. The response is mostly transient and is observed in 50% of the treated patients, suggesting a bone turnover that can be assessed clinically and radiographically.

  16. Osseous outgrowth on the buccal maxilla associated with piezosurgery-assisted en-masse retraction: A case series

    PubMed Central

    Arman-Özçırpıcı, Ayça; Oduncuoğlu, Bahar Füsun; Kantarcı, Alpdoğan

    2018-01-01

    Piezoelectric surgery is a novel surgical approach used in orthodontic treatment for rapid tooth movement. This paper presents a case series wherein osseous outgrowths were observed in response to piezosurgery-assisted en-masse retraction. Sixteen patients requiring upper premolar extractions were treated with miniscrew-supported en-masse retraction and received minimally invasive decortication via piezosurgery. Computed tomography (CT) of the maxillary anterior region was performed to investigate the nature of the outgrowths. In 8 of the 16 patients, hemispheric or disc-shaped osseous outgrowths were observed on the sites where piezosurgery was performed during retraction. CT images revealed that these outgrowths were alveolar bone. This case series presents a previously unreported osseous response to piezosurgery-assisted tooth movement during orthodontic treatment. The response is mostly transient and is observed in 50% of the treated patients, suggesting a bone turnover that can be assessed clinically and radiographically. PMID:29291189

  17. A multimedia Electronic Patient Record (ePR) system for Image-Assisted Minimally Invasive Spinal Surgery

    PubMed Central

    Documet, Jorge; Le, Anh; Liu, Brent; Chiu, John; Huang, HK

    2009-01-01

    Purpose This paper presents the concept of bridging the gap between diagnostic images and image-assisted surgical treatment through the development of a one-stop multimedia electronic patient record (ePR) system that manages and distributes the real-time multimodality imaging and informatics data that assists the surgeon during all clinical phases of the operation from planning Intra-Op to post-care follow-up. We present the concept of this multimedia ePR for surgery by first focusing on Image-Assisted Minimally Invasive Spinal Surgery as a clinical application. Methods Three clinical Phases of Minimally Invasive Spinal Surgery workflow in Pre-Op, Intra-Op, and Post Op are discussed. The ePR architecture was developed based on the three-phased workflow, which includes the Pre-Op, Intra-Op, and Post-Op modules and four components comprising of the input integration unit, fault-tolerant gateway server, fault-tolerant ePR server, and the visualization and display. A prototype was built and deployed to a Minimally Invasive Spinal Surgery clinical site with user training and support for daily use. Summary A step-by step approach was introduced to develop a multi-media ePR system for Imaging-Assisted Minimally Invasive Spinal Surgery that includes images, clinical forms, waveforms, and textual data for planning the surgery, two real-time imaging techniques (digital fluoroscopic, DF) and endoscope video images (Endo), and more than half a dozen live vital signs of the patient during surgery. Clinical implementation experiences and challenges were also discussed. PMID:20033507

  18. Clinical evaluation of complete solo surgery with the "ViKY®" robotic laparoscope manipulator.

    PubMed

    Takahashi, Masahiro; Takahashi, Masanori; Nishinari, Naoto; Matsuya, Hideki; Tosha, Tsutomu; Minagawa, Yukihiro; Shimooki, Osamu; Abe, Tadashi

    2017-02-01

    Advancement in both surgical technique and medical equipment has enabled solo surgery. ViKY ® Endoscope Positioning System (ViKY ® ) is a robotic system that remotely controls an endoscope and provides direct vision control to the surgeon. Here, we report our experience with ViKY ® -assisted solo surgery. We retrospectively examined 25 cases of solo surgery TAPP with ViKY ® . ViKY ® was setup by the surgeon alone, and the setup duration was determined as the time at which the side rail was positioned and that when the endoscope was installed. For assessing the control unit, the number of false movements was counted. We compared the operative results between ViKY ® -assisted solo surgery TAPP and the conventional method with an assistant. The average time to set up ViKY ® was 7.9 min. The average number of commands for ViKY ® during surgery was 98.3, and the average number of errors and no response of control unit was 7.9. The mean duration of surgery was 136 min for the ViKY ® group, including the setup time, and 117 min for the conventional method. No case required an assistant during the operation. There was also no difference between the two groups with regard to postoperative complications and the rate of recurrence. ViKY ® proved reliable in recognizing orders with very few failures, and the operations were performed safely and were comparable to the conventional operations with assistants. Solo surgery with ViKY ® was beneficial in this clinical evaluation.

  19. Robotic assisted kidney transplantation

    PubMed Central

    Modi, Pranjal; Pal, Bipinchandra; Modi, Jayesh; Kumar, Suresh; Sood, Akshay; Menon, Mani

    2014-01-01

    Kidney transplantation is the standard of care for patients with end stage renal disease. While open surgery remains the gold standard, minimally invasive surgery has recently been introduced for the recipient undergoing kidney transplantation. We review the evolution of techniques of minimally invasive surgery for kidney transplantation with specific emphasis on technical aspects of robotic assisted kidney transplantation. PMID:25097315

  20. Virtual planning for craniomaxillofacial surgery--7 years of experience.

    PubMed

    Adolphs, Nicolai; Haberl, Ernst-Johannes; Liu, Weichen; Keeve, Erwin; Menneking, Horst; Hoffmeister, Bodo

    2014-07-01

    Contemporary computer-assisted surgery systems more and more allow for virtual simulation of even complex surgical procedures with increasingly realistic predictions. Preoperative workflows are established and different commercially software solutions are available. Potential and feasibility of virtual craniomaxillofacial surgery as an additional planning tool was assessed retrospectively by comparing predictions and surgical results. Since 2006 virtual simulation has been performed in selected patient cases affected by complex craniomaxillofacial disorders (n = 8) in addition to standard surgical planning based on patient specific 3d-models. Virtual planning could be performed for all levels of the craniomaxillofacial framework within a reasonable preoperative workflow. Simulation of even complex skeletal displacements corresponded well with the real surgical result and soft tissue simulation proved to be helpful. In combination with classic 3d-models showing the underlying skeletal pathology virtual simulation improved planning and transfer of craniomaxillofacial corrections. Additional work and expenses may be justified by increased possibilities of visualisation, information, instruction and documentation in selected craniomaxillofacial procedures. Copyright © 2013 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  1. Robotic Surgery in Gynecology

    PubMed Central

    Bouquet de Joliniere, Jean; Librino, Armando; Dubuisson, Jean-Bernard; Khomsi, Fathi; Ben Ali, Nordine; Fadhlaoui, Anis; Ayoubi, J. M.; Feki, Anis

    2016-01-01

    Minimally invasive surgery (MIS) can be considered as the greatest surgical innovation over the past 30 years. It revolutionized surgical practice with well-proven advantages over traditional open surgery: reduced surgical trauma and incision-related complications, such as surgical-site infections, postoperative pain and hernia, reduced hospital stay, and improved cosmetic outcome. Nonetheless, proficiency in MIS can be technically challenging as conventional laparoscopy is associated with several limitations as the two-dimensional (2D) monitor reduction in-depth perception, camera instability, limited range of motion, and steep learning curves. The surgeon has a low force feedback, which allows simple gestures, respect for tissues, and more effective treatment of complications. Since the 1980s, several computer sciences and robotics projects have been set up to overcome the difficulties encountered with conventional laparoscopy, to augment the surgeon’s skills, achieve accuracy and high precision during complex surgery, and facilitate widespread of MIS. Surgical instruments are guided by haptic interfaces that replicate and filter hand movements. Robotically assisted technology offers advantages that include improved three-dimensional stereoscopic vision, wristed instruments that improve dexterity, and tremor canceling software that improves surgical precision. PMID:27200358

  2. Real-time advanced spinal surgery via visible patient model and augmented reality system.

    PubMed

    Wu, Jing-Ren; Wang, Min-Liang; Liu, Kai-Che; Hu, Ming-Hsien; Lee, Pei-Yuan

    2014-03-01

    This paper presents an advanced augmented reality system for spinal surgery assistance, and develops entry-point guidance prior to vertebroplasty spinal surgery. Based on image-based marker detection and tracking, the proposed camera-projector system superimposes pre-operative 3-D images onto patients. The patients' preoperative 3-D image model is registered by projecting it onto the patient such that the synthetic 3-D model merges with the real patient image, enabling the surgeon to see through the patients' anatomy. The proposed method is much simpler than heavy and computationally challenging navigation systems, and also reduces radiation exposure. The system is experimentally tested on a preoperative 3D model, dummy patient model and animal cadaver model. The feasibility and accuracy of the proposed system is verified on three patients undergoing spinal surgery in the operating theater. The results of these clinical trials are extremely promising, with surgeons reporting favorably on the reduced time of finding a suitable entry point and reduced radiation dose to patients. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  3. Robotic assisted surgery in pediatric gynecology: promising innovation in mini invasive surgical procedures.

    PubMed

    Nakib, Ghassan; Calcaterra, Valeria; Scorletti, Federico; Romano, Piero; Goruppi, Ilaria; Mencherini, Simonetta; Avolio, Luigi; Pelizzo, Gloria

    2013-02-01

    Robotic assisted surgery is not yet widely applied in the pediatric field. We report our initial experience regarding the feasibility, safety, benefits, and limitations of robot-assisted surgery in pediatric gynecological patients. Descriptive, retrospective report of experience with pediatric gynecological patients over a period of 12 months. Department of Pediatric Surgery, IRCCS Policlinico San Matteo Foundation. Children and adolescents, with a surgical diagnosis of ovarian and/or tubal lesions. Robot assembly time and operative time, days of hospitalization, time to cessation of pain medication, complication rate, conversion rate to laparoscopic procedure and trocar insertion strategy. Six children and adolescents (2.4-15 yrs), weighing 12-55 kg, underwent robotic assisted surgery for adnexal pathologies: 2 for ovarian cystectomy, 2 for oophorectomy, 1 for right oophorectomy and left salpingo-oophorectomy for gonadal disgenesis, 1 for exploration for suspected pelvic malformation. Mean operative time was 117.5 ± 34.9 minutes. Conversion to laparatomy was not necessary in any of the cases. No intra- or postoperative complications occurred. Initial results indicate that robotic assisted surgery is safely applicable in the pediatric gynecological population, although it is still premature to conclude that it provides better clinical outcomes than traditional laparoscopic surgery. Randomized, prospective, comparative studies will help characterize the advantages and disadvantages of this new technology in pediatric patients. Copyright © 2013 North American Society for Pediatric and Adolescent Gynecology. Published by Elsevier Inc. All rights reserved.

  4. Quantitative validation of a computer-aided maxillofacial planning system, focusing on soft tissue deformations.

    PubMed

    Nadjmi, Nasser; Defrancq, Ellen; Mollemans, Wouter; Hemelen, Geert Van; Bergé, Stefaan

    2014-01-01

    The aim of this study was to evaluate the accuracy of 3D soft tissue predictions generated by a computer-aided maxillofacial planning system in patients undergoing orthognathic surgery. Twenty patients with dentofacial dysmorphosis were treated with orthognathic surgery after a preoperative orthodontic treatment. Fourteen patients had an Angle Class II malocclusion; three patients had an Angle class III malocclusion, and three patients had an Angle Class I malocclusion. Skeletal asymmetry was observed in six patient. The surgeries were planned using the Maxilim software. Computer assisted surgical planning was transferred to the patient by digitally generated splints. The validation procedures were performed in the following steps: (1) Standardized registration of the pre- and postoperative Cone Beam CT volumes; (2) Automated adjustment of the bone-related planning to the actual operative bony displacement; (3) Simulation of soft tissue changes; (4) Calculation of the soft tissue differences between the predicted and the postoperative results by distance mapping. Eighty four percent of the mapped distances between the predicted and actual postoperative results measured between -2 mm and +2 mm. The mean absolute linear measurements between the predicted and actual postoperative surface was 1.18. Our study shows the overall prediction was dependent on neither the surgical procedures nor the dentofacial deformity type. Despite some shortcomings in the prediction of the final position of the lower lip and cheek area, this software promises a clinically acceptable soft tissue prediction for orthognathic surgical procedures.

  5. Feasibility and safety of augmented reality-assisted urological surgery using smartglass.

    PubMed

    Borgmann, H; Rodríguez Socarrás, M; Salem, J; Tsaur, I; Gomez Rivas, J; Barret, E; Tortolero, L

    2017-06-01

    To assess the feasibility, safety and usefulness of augmented reality-assisted urological surgery using smartglass (SG). Seven urological surgeons (3 board urologists and 4 urology residents) performed augmented reality-assisted urological surgery using SG for 10 different types of operations and a total of 31 urological operations. Feasibility was assessed using technical metadata (number of photographs taken/number of videos recorded/video time recorded) and structured interviews with the urologists on their use of SG. Safety was evaluated by recording complications and grading according to the Clavien-Dindo classification. Usefulness of SG for urological surgery was queried in structured interviews and in a survey. The implementation of SG use during urological surgery was feasible with no intrinsic (technical defect) or extrinsic (inability to control the SG function) obstacles being observed. SG use was safe as no grade 3-5 complications occurred for the series of 31 urological surgeries of different complexities. Technical applications of SG included taking photographs/recording videos for teaching and documentation, hands-free teleconsultation, reviewing patients' medical records and images and searching the internet for health information. Overall usefulness of SG for urological surgery was rated as very high by 43 % and high by 29 % of surgeons. Augmented reality-assisted urological surgery using SG is both feasible and safe and also provides several useful functions for urological surgeons. Further developments and investigations are required in the near future to harvest the great potential of this exciting technology for urological surgery.

  6. Spring assisted cranioplasty: A patient specific computational model.

    PubMed

    Borghi, Alessandro; Rodriguez-Florez, Naiara; Rodgers, Will; James, Gregory; Hayward, Richard; Dunaway, David; Jeelani, Owase; Schievano, Silvia

    2018-03-01

    Implantation of spring-like distractors in the treatment of sagittal craniosynostosis is a novel technique that has proven functionally and aesthetically effective in correcting skull deformities; however, final shape outcomes remain moderately unpredictable due to an incomplete understanding of the skull-distractor interaction. The aim of this study was to create a patient specific computational model of spring assisted cranioplasty (SAC) that can help predict the individual overall final head shape. Pre-operative computed tomography images of a SAC patient were processed to extract a 3D model of the infant skull anatomy and simulate spring implantation. The distractors were modeled based on mechanical experimental data. Viscoelastic bone properties from the literature were tuned using the specific patient procedural information recorded during surgery and from x-ray measurements at follow-up. The model accurately captured spring expansion on-table (within 9% of the measured values), as well as at first and second follow-ups (within 8% of the measured values). Comparison between immediate post-operative 3D head scanning and numerical results for this patient proved that the model could successfully predict the final overall head shape. This preliminary work showed the potential application of computational modeling to study SAC, to support pre-operative planning and guide novel distractor design. Copyright © 2018 IPEM. Published by Elsevier Ltd. All rights reserved.

  7. Robotic Camera Assistance and Its Benefit in 1033 Traditional Laparoscopic Procedures: Prospective Clinical Trial Using a Joystick-guided Camera Holder.

    PubMed

    Holländer, Sebastian W; Klingen, Hans Joachim; Fritz, Marliese; Djalali, Peter; Birk, Dieter

    2014-11-01

    Despite advances in instruments and techniques in laparoscopic surgery, one thing remains uncomfortable: the camera assistance. The aim of this study was to investigate the benefit of a joystick-guided camera holder (SoloAssist®, Aktormed, Barbing, Germany) for laparoscopic surgery and to compare the robotic assistance to human assistance. 1033 consecutive laparoscopic procedures were performed assisted by the SoloAssist®. Failures and aborts were documented and nine surgeons were interviewed by questionnaire regarding their experiences. In 71 of 1033 procedures, robotic assistance was aborted and the procedure was continued manually, mostly because of frequent changes of position, narrow spaces, and adverse angular degrees. One case of short circuit was reported. Emergency stop was necessary in three cases due to uncontrolled movement into the abdominal cavity. Eight of nine surgeons prefer robotic to human assistance, mostly because of a steady image and self-control. The SoloAssist® robot is a reliable system for laparoscopic procedures. Emergency shutdown was necessary in only three cases. Some minor weak spots could have been identified. Most surgeons prefer robotic assistance to human assistance. We feel that the SoloAssist® makes standard laparoscopic surgery more comfortable and further development is desirable, but it cannot fully replace a human assistant.

  8. Surgical management of cross-bites in orthognathic surgery: Surgically assisted rapid maxillary expansion (SARME) versus two-piece maxilla.

    PubMed

    Seeberger, Robin; Gander, Evelyn; Hoffmann, Jürgen; Engel, Michael

    2015-09-01

    The surgical treatment of cross-bites includes surgically-assisted maxillary expansion (SARME) or maxillary-bipartition during bimaxillary surgery. This study evaluates and compares the changes in the teeth and lower nasal passage, as well as the stability of the expansion. The measurements were performed on the cone-beam computed tomography (CBCT) scans of 32 patients with transverse (width) deficiencies of the maxilla. To expand the maxilla, 12 patients underwent the two-piece maxilla method, while 20 patients received SARME. The mean distraction width for SARME was 6.8 mm (SD 3.7), while that for the two-piece maxilla was 4.1 mm (SD 1.6). The expansion with SARME was over the entire length of the maxilla, from anterior to posterior, whereas the expansion of the two-piece patient group was only in the posterior part of the maxilla. The segments of the maxilla opened nearly parallel in SARME, while they were reverse V-shaped in the two-piece maxilla, from anterior to posterior. A key point in the planning of combined orthodontic-orthognathic therapy with surgical correction of a cross-bite is the precise determination of the area where the width needs to be increased, and the amount of correction needed to treat the patient using minimal surgical procedures. Copyright © 2015 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  9. Robot-assisted laparoscopic staging surgery for endometrial cancer--a preliminary report.

    PubMed

    Lee, Chyi-Long; Han, Chien-Min; Su, Hsuan; Wu, Kai-Yun; Wang, Chin-Jung; Yen, Chih-Feng

    2010-12-01

    The robotic surgical system is reported to overcome some technical difficulties in traditional laparoscopic hysterectomy. This study aimed to evaluate the feasibility and surgical outcomes of a robotic surgery program for endometrial cancer. Patients with endometrial cancer with the intention to receive treatment using robot-assisted laparoscopic staging surgery were recruited in a university hospital from July 2007 to August 2008. All of these surgeries were performed with the da Vinci system. Six patients (mean age, 47.5 ±1.4 years; mean body mass index, 26.2 ±3.5 kg/m(2)) were enrolled and completed robot-assisted laparoscopic staging surgery. The robot docking time was 45.0 ±13.6 minutes and the robot-assisted operation time was 200.3 ±30.0 minutes. The mean estimated blood loss was 180.0 ±147.6 mL. The mean number of lymph nodes retrieved was 23.2 ±7.4. No laparoconversion and no intraoperative or postoperative complications occurred. All patients were alive and free of disease up to the date of this report, at a median follow-up of 6.5 months (range, 5-17 months). Robot-assisted laparoscopic staging surgery is a feasible treatment and helps overcome the technical limitations in conventional laparoscopy for endometrial cancer. Copyright © 2010 Taiwan Association of Obstetric & Gynecology. Published by Elsevier B.V. All rights reserved.

  10. The role of three-dimensional visualization in robotics-assisted cardiac surgery

    NASA Astrophysics Data System (ADS)

    Currie, Maria; Trejos, Ana Luisa; Rayman, Reiza; Chu, Michael W. A.; Patel, Rajni; Peters, Terry; Kiaii, Bob

    2012-02-01

    Objectives: The purpose of this study was to determine the effect of three-dimensional (3D) versus two-dimensional (2D) visualization on the amount of force applied to mitral valve tissue during robotics-assisted mitral valve annuloplasty, and the time to perform the procedure in an ex vivo animal model. In addition, we examined whether these effects are consistent between novices and experts in robotics-assisted cardiac surgery. Methods: A cardiac surgery test-bed was constructed to measure forces applied by the da Vinci surgical system (Intuitive Surgical, Sunnyvale, CA) during mitral valve annuloplasty. Both experts and novices completed roboticsassisted mitral valve annuloplasty with 2D and 3D visualization. Results: The mean time for both experts and novices to suture the mitral valve annulus and to tie sutures using 3D visualization was significantly less than that required to suture the mitral valve annulus and to tie sutures using 2D vision (p∠0.01). However, there was no significant difference in the maximum force applied by novices to the mitral valve during suturing (p = 0.3) and suture tying (p = 0.6) using either 2D or 3D visualization. Conclusion: This finding suggests that 3D visualization does not fully compensate for the absence of haptic feedback in robotics-assisted cardiac surgery. Keywords: Robotics-assisted surgery, visualization, cardiac surgery

  11. Video-assisted thoracoscopic surgery lobectomy via confronting upside-down monitor setting

    PubMed Central

    Ichinose, Junji; Matsuura, Yosuke; Nakao, Masayuki; Okumura, Sakae

    2017-01-01

    Video-assisted thoracoscopic surgery (VATS) has been widely accepted as a minimally invasive surgery for treatment of early-stage lung cancer. However, various VATS approaches are available. In patients with lung cancer, VATS should achieve not only minimal invasiveness but also safety and oncological clearance. In this article, we introduce our method of VATS lobectomy. PMID:29078689

  12. Subxiphoid uniportal video-assisted thoracoscopic surgery for synchronous bilateral lung resection.

    PubMed

    Yang, Xueying; Wang, Linlin

    2018-01-01

    With advancements in medical imaging and current emphasis on regular physical examinations, multiple pulmonary lesions increasingly are being detected, including bilateral pulmonary lesions. Video-assisted thoracic surgery is an important method for treating such lesions. Most of video-assisted thoracic surgeries for bilateral pulmonary lesions were two separate operations. Herein, we report a novel technique of synchronous subxiphoid uniportal video-assisted thoracic surgery for bilateral pulmonary lesions. Synchronous bilateral lung resection procedures were performed through a single incision (~4 cm, subxiphoid). This technique was used successfully in 11 patients with bilateral pulmonary lesions. There were no intraoperative deaths or mortality recorded at 30 days. Our results show that the subxiphoid uniportal thoracoscopic procedure is a safe and feasible surgical procedure for synchronous bilateral lung resection with less surgical trauma, postoperative pain and better cosmetic results in qualifying patients. Further analysis is ongoing, involving a larger number of subjects.

  13. Scoliosis surgery - child

    MedlinePlus

    Spinal curvature surgery - child; Kyphoscoliosis surgery - child; Video-assisted thoracoscopic surgery - child; VATS - child ... may also do the procedure using a special video camera. A surgical cut in the back is ...

  14. Navigated versus conventional total knee arthroplasty: A prospective study at three years follow-up.

    PubMed

    Martín-Hernández, C; Sanz-Sainz, M; Revenga-Giertych, C; Hernández-Vaquero, D; Fernández-Carreira, J M; Albareda-Albareda, J; Castillo-Palacios, A; Ranera-Garcia, M

    2018-03-28

    Computer-assisted surgery application in total knee arthroplasty (TKA) has shown more accurate implant alignment compared with conventional instrumentation and is associated with more homogeneous alignment results. Although longer implant survival and superior clinical outcomes should be expected from navigated TKA, currently available evidence does not support this hypothesis. The aim of this study was to compare navigated TKA with conventional TKA regarding clinical and radiological outcomes after a 3-year follow-up under the hypothesis that navigated TKA would provide better outcomes than conventional TKA. In a prospective multicentre study, 119 patients underwent navigated TKA and 80 patients received conventional instrumentation. Patients were evaluated at the baseline and at postoperative months 3, 12, 24, and 36. Analysis included the American Knee Society Score (KSS), Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), Short Form-12 (SF12) Health Survey, and radiographic assessment. All clinical scores improved significantly for all patients during the follow-up but were significantly better in the navigation group. The percentage of patients showing a mechanical axis between 3° of varus and 3° of valgus was significantly higher in the ATR group (93%) than in the conventional TKA group (71%) (P<.01). The use of computer-assisted surgery in TKA provides more accurate mechanical alignment and superior short-term functional outcomes compared to conventional TKA. Copyright © 2018 SECOT. Publicado por Elsevier España, S.L.U. All rights reserved.

  15. Short-term outcome of 1,465 computer-navigated primary total knee replacements 2005-2008.

    PubMed

    Gøthesen, Oystein; Espehaug, Birgitte; Havelin, Leif; Petursson, Gunnar; Furnes, Ove

    2011-06-01

    and purpose Improvement of positioning and alignment by the use of computer-assisted surgery (CAS) might improve longevity and function in total knee replacements, but there is little evidence. In this study, we evaluated the short-term results of computer-navigated knee replacements based on data from the Norwegian Arthroplasty Register. Primary total knee replacements without patella resurfacing, reported to the Norwegian Arthroplasty Register during the years 2005-2008, were evaluated. The 5 most common implants and the 3 most common navigation systems were selected. Cemented, uncemented, and hybrid knees were included. With the risk of revision for any cause as the primary endpoint and intraoperative complications and operating time as secondary outcomes, 1,465 computer-navigated knee replacements (CAS) and 8,214 conventionally operated knee replacements (CON) were compared. Kaplan-Meier survival analysis and Cox regression analysis with adjustment for age, sex, prosthesis brand, fixation method, previous knee surgery, preoperative diagnosis, and ASA category were used. Kaplan-Meier estimated survival at 2 years was 98% (95% CI: 97.5-98.3) in the CON group and 96% (95% CI: 95.0-97.8) in the CAS group. The adjusted Cox regression analysis showed a higher risk of revision in the CAS group (RR = 1.7, 95% CI: 1.1-2.5; p = 0.02). The LCS Complete knee had a higher risk of revision with CAS than with CON (RR = 2.1, 95% CI: 1.3-3.4; p = 0.004)). The differences were not statistically significant for the other prosthesis brands. Mean operating time was 15 min longer in the CAS group. With the introduction of computer-navigated knee replacement surgery in Norway, the short-term risk of revision has increased for computer-navigated replacement with the LCS Complete. The mechanisms of failure of these implantations should be explored in greater depth, and in this study we have not been able to draw conclusions regarding causation.

  16. Robot-assisted thoracoscopic surgery with simple laparoscopy for diaphragm eventration.

    PubMed

    Ahn, Joong Hyun; Suh, Jong Hui; Jeong, Jin Yong

    2013-09-01

    Robot-assisted thoracoscopic surgery has been applied for general thoracic operations. Its advantages include not only those of minimally invasive surgery but also those of magnified three-dimensional vision and angulation of the robotic arm. However, there are no direct tactile sensation and force feedback, which can cause unwanted organ damage. We therefore used laparoscopy simultaneously to avoid a blind intraperitoneal area during robotic surgery for diaphragmatic eventration via transthoracic approach and describe the technique herein. Georg Thieme Verlag KG Stuttgart · New York.

  17. Implant alignment in total elbow arthroplasty: conventional vs. navigated techniques

    NASA Astrophysics Data System (ADS)

    McDonald, Colin P.; Johnson, James A.; King, Graham J. W.; Peters, Terry M.

    2009-02-01

    Incorrect selection of the native flexion-extension axis during implant alignment in elbow replacement surgery is likely a significant contributor to failure of the prosthesis. Computer and image-assisted surgery is emerging as a useful surgical tool in terms of improving the accuracy of orthopaedic procedures. This study evaluated the accuracy of implant alignment using an image-based navigation technique compared against a conventional non-navigated approach. Implant alignment error was 0.8 +/- 0.3 mm in translation and 1.1 +/- 0.4° in rotation for the navigated alignment, compared with 3.1 +/- 1.3 mm and 5.0 +/- 3.8° for the non-navigated alignment. Five (5) of the 11 non-navigated alignments were malaligned greater than 5° while none of the navigated alignments were placed with an error of greater than 2.0°. It is likely that improved implant positioning will lead to reduced implant loading and wear, resulting in fewer implantrelated complications and revision surgeries.

  18. Intra- and extra-articular planes of reference for use in total hip arthroplasty: a preliminary study.

    PubMed

    Hausselle, Jerome; Moreau, Pierre Etienne; Wessely, Loic; de Thomasson, Emmanuel; Assi, Ayman; Parratte, Sebastien; Essig, Jerome; Skalli, Wafa

    2012-08-01

    Acetabular component malalignment in total hip arthroplasty can lead to potential complications such as dislocation, component impingement and excessive wear. Computer-assisted orthopaedic surgery systems generally use the anterior pelvic plane (APP). Our aim was to investigate the reliability of anatomical landmarks accessible during surgery and to define new potential planes of reference. Three types of palpations were performed: virtual, on dry bones and on two cadaveric specimens. Four landmarks were selected, the reproducibility of their positioning ranging from 0.9 to 2.3 mm. We then defined five planes and tested them during palpations on two cadaveric specimens. Two planes produced a mean orientation error of 5.0° [standard deviation (SD 3.3°)] and 5.6° (SD 2.7°). Even if further studies are needed to test the reliability of such planes on a larger scale in vivo during surgery, these results demonstrated the feasibility of defining a new plane of reference as an alternative to the APP.

  19. Microdebrider-assisted uvulopalatoplasty.

    PubMed

    Tarabichi, M

    1998-07-01

    This report describes 3 years' experience with the microdebrider as a safe and reasonable alternative to CO2 laser for uvulopalatoplasty. The cost and compact size of the equipment, as well as the ease of surgery, are the main advantages for microdebrider-assisted surgery.

  20. Is a computer-assisted design and computer-assisted manufacturing method for mandibular reconstruction economically viable?

    PubMed

    Tarsitano, Achille; Battaglia, Salvatore; Crimi, Salvatore; Ciocca, Leonardo; Scotti, Roberto; Marchetti, Claudio

    2016-07-01

    The design and manufacture of patient-specific mandibular reconstruction plates, particularly in combination with cutting guides, has created many new opportunities for the planning and implementation of mandibular reconstruction. Although this surgical method is being used more widely and the outcomes appear to be improved, the question of the additional cost has to be discussed. To evaluate the cost generated by the management of this technology, we studied a cohort of patients treated for mandibular neoplasms. The population was divided into two groups of 20 patients each who were undergoing a 'traditional' freehand mandibular reconstruction or a computer-aided design/computer-aided manufacturing (CAD-CAM) mandibular reconstruction. Data concerning operation time, complications, and days of hospitalisation were used to evaluate costs related to the management of these patients. The mean operating time for the CAD-CAM group was 435 min, whereas that for the freehand group was 550.5 min. The total difference in terms of average time gain was 115.5 min. No microvascular complication occurred in the CAD-CAM group; two complications (10%) were observed in patients undergoing freehand reconstructions. The mean overall lengths of hospital stay were 13.8 days for the CAD-CAM group and 17 days for the freehand group. Finally, considering that the institutional cost per minute of theatre time is €30, the money saved as a result of the time gained was €3,450. This cost corresponds approximately to the total price of the CAD-CAM surgery. In conclusion, we believe that CAD-CAM technology for mandibular reconstruction will become a widely used reconstructive method and that its cost will be covered by gains in terms of surgical time, quality of reconstruction, and reduced complications. Copyright © 2016 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  1. Comparison of endoscopic-assisted and temporary keratoprosthesis-assisted vitrectomy in combat ocular trauma: experience at a tertiary eye center in Turkey.

    PubMed

    Ayyildiz, Onder; Hakan Durukan, Ali

    2018-01-01

    Objective This study was performed to compare the functional and anatomical results of endoscopic-assisted and temporary keratoprosthesis (TKP)-assisted vitrectomy in patients with combat ocular trauma (COT). Methods The medical records of 14 severely injured eyes of 12 patients who underwent endoscopy or TKP implantation in combination with vitreoretinal surgery from 2007 to 2015 were retrospectively evaluated. The patients' ocular history and functional and anatomic anterior and posterior segment results were analyzed. Results Eight eyes (57%) underwent TKP-assisted vitrectomy and six eyes (43%) underwent endoscopic vitrectomy. The most common cause of COT was detonation of improvised explosive devices (72%), and the most common type of injury was an intraocular foreign body (50%). The median time from trauma to surgery and the median surgical time were significantly shorter in the endoscopy than TKP group. The postoperative functional and anatomical results were not significantly different between the two groups. Conclusions TKP-assisted vitrectomy should be performed in eyes requiring extensive bimanual surgery. In such cases, a corneal graft must be preserved for the TKP at the end of the surgery. Endoscopy shortens the surgical time and can reduce the complication rate.

  2. Development of a femoral template for computer-assisted tunnel placement in anatomical double-bundle ACL reconstruction.

    PubMed

    Luites, J W H; Wymenga, A B; Blankevoort, L; Kooloos, J M G; Verdonschot, N

    2011-01-01

    Femoral graft placement is an important factor in the success of anterior cruciate ligament (ACL) reconstruction. In addition to improving the accuracy of femoral tunnel placement, Computer Assisted Surgery (CAS) can be used to determine the anatomic location. This is achieved by using a 3D femoral template which indicates the position of the anatomical ACL center based on endoscopically measurable landmarks. This study describes the development and application of this method. The template is generated through statistical shape analysis of the ACL insertion, with respect to the anteromedial (AM) and posterolateral (PL) bundles. The ligament insertion data, together with the osteocartilage edge on the lateral notch, were mapped onto a cylinder fitted to the intercondylar notch surface (n = 33). Anatomic variation, in terms of standard variation of the positions of the ligament centers in the template, was within 2.2 mm. The resulting template was programmed in a computer-assisted navigation system for ACL replacement and its accuracy and precision were determined on 31 femora. It was found that with the navigation system the AM and PL tunnels could be positioned with an accuracy of 2.5 mm relative to the anatomic insertion centers; the precision was 2.4 mm. This system consists of a template that can easily be implemented in 3D computer navigation software. Requiring no preoperative images and planning, the system provides adequate accuracy and precision to position the entrance of the femoral tunnels for anatomical single- or double-bundle ACL reconstruction.

  3. Development of a teaching tool for women with a gynecologic malignancy undergoing minimally invasive robotic-assisted surgery.

    PubMed

    Castiglia, Luisa Luciani; Drummond, Nancy; Purden, Margaret A

    2011-08-01

    Women undergoing minimally invasive robotic-assisted surgery for a gynecologic malignancy have many questions and concerns related to the cancer diagnosis and surgery. The provision of information enhances coping with such illness-related challenges. A lack of print materials for these patients prompted the creation of a written teaching tool to improve informational support. A booklet was developed using guidelines for the design of effective patient education materials, including an iterative process of collaboration with healthcare providers and women who had undergone robotic-assisted surgery, as well as attention to readability. The 52-page booklet covers the trajectory of the woman's experience and includes the physical, psychosocial, and sexual aspects of recovery.

  4. Initial experience with the new da Vinci single-port robot-assisted platform.

    PubMed

    Ballestero Diego, R; Zubillaga Guerrero, S; Truan Cacho, D; Carrion Ballardo, C; Velilla Diez, G; Calleja Hermosa, P; Gutiérrez Baños, J L

    2017-06-01

    To describe our experience in the first cases of urological surgeries performed with the da Vinci single-port robot-assisted platform. We performed 5 single-port robot-assisted surgeries (R-LESS) between May and October 2014. We performed 3 ureteral reimplant surgeries, one ureteropyeloplasty in an inverted kidney and 1 partial nephrectomy. The perioperative and postoperative results were collected, as well as a report of the complications according to the Clavien classification system. Of the 5 procedures, 4 were performed completely by LESS, while 1 procedure was reconverted to multiport robot-assisted surgery. There were no intraoperative complications. We observed perioperative complications in 4 patients, all of which were grade 1 or 2. The mean surgical time was 262minutes (range, 230-300). In our initial experience with the da Vinci device, R-LESS surgery was feasible and safe. There are still a number of limitations in its use, which require new and improved R-LESS platforms. Copyright © 2016 AEU. Publicado por Elsevier España, S.L.U. All rights reserved.

  5. Use of computer-assisted design and manufacturing to localize dural venous sinuses during reconstructive surgery for craniosynostosis.

    PubMed

    Iyer, Rajiv R; Wu, Adela; Macmillan, Alexandra; Musavi, Leila; Cho, Regina; Lopez, Joseph; Jallo, George I; Dorafshar, Amir H; Ahn, Edward S

    2018-01-01

    Cranial vault remodeling surgery for craniosynostosis carries the potential risk of dural venous sinus injury given the extensive bony exposure. Identification of the dural venous sinuses can be challenging in patients with craniosynostosis given the lack of accurate surface-localizing landmarks. Computer-aided design and manufacturing (CAD/CAM) has allowed surgeons to pre-operatively plan these complex procedures in an effort to increase reconstructive efficiency. An added benefit of this technology is the ability to intraoperatively map the dural venous sinuses based on pre-operative imaging. We utilized CAD/CAM technology to intraoperatively map the dural venous sinuses for patients undergoing reconstructive surgery for craniosynostosis in an effort to prevent sinus injury, increase operative efficiency, and enhance patient safety. Here, we describe our experience utilizing this intraoperative technology in pediatric patients with craniosynostosis. We retrospectively reviewed the charts of children undergoing reconstructive surgery for craniosynostosis using CAD/CAM surgical planning guides at our institution between 2012 and 2016. Data collected included the following: age, gender, type of craniosynostosis, estimated blood loss, sagittal sinus deviation from the sagittal suture, peri-operative outcomes, and hospital length of stay. Thirty-two patients underwent reconstructive cranial surgery for craniosynostosis, with a median age of 11 months (range, 7-160). Types of synostosis included metopic (6), unicoronal (6), sagittal (15), lambdoid (1), and multiple suture (4). Sagittal sinus deviation from the sagittal suture was maximal in unicoronal synostosis patients (10.2 ± 0.9 mm). All patients tolerated surgery well, and there were no occurrences of sagittal sinus, transverse sinus, or torcular injury. The use of CAD/CAM technology allows for accurate intraoperative dural venous sinus localization during reconstructive surgery for craniosynostosis and enhances operative efficiency and surgeon confidence while minimizing the risk of patient morbidity.

  6. Video-assisted thoracic surgery mediastinal germ cell metastasis resection.

    PubMed

    Nardini, Marco; Jayakumar, Shruti; Migliore, Marcello; Dunning, Joel

    2017-07-01

    Thoracoscopy can be safely used for dissection of masses in the visceral mediastinum. We report the case of a 31-year-old man affected by metastatic germ cell tumour and successfully treated with a 3-port posterior approach video-assisted thoracic surgery. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  7. Robotic assisted andrological surgery

    PubMed Central

    Parekattil, Sijo J; Gudeloglu, Ahmet

    2013-01-01

    The introduction of the operative microscope for andrological surgery in the 1970s provided enhanced magnification and accuracy, unparalleled to any previous visual loop or magnification techniques. This technology revolutionized techniques for microsurgery in andrology. Today, we may be on the verge of a second such revolution by the incorporation of robotic assisted platforms for microsurgery in andrology. Robotic assisted microsurgery is being utilized to a greater degree in andrology and a number of other microsurgical fields, such as ophthalmology, hand surgery, plastics and reconstructive surgery. The potential advantages of robotic assisted platforms include elimination of tremor, improved stability, surgeon ergonomics, scalability of motion, multi-input visual interphases with up to three simultaneous visual views, enhanced magnification, and the ability to manipulate three surgical instruments and cameras simultaneously. This review paper begins with the historical development of robotic microsurgery. It then provides an in-depth presentation of the technique and outcomes of common robotic microsurgical andrological procedures, such as vasectomy reversal, subinguinal varicocelectomy, targeted spermatic cord denervation (for chronic orchialgia) and robotic assisted microsurgical testicular sperm extraction (microTESE). PMID:23241637

  8. Conditional long-term survival following minimally invasive robotic mitral valve repair: a health services perspective.

    PubMed

    Efird, Jimmy T; Griffin, William F; Gudimella, Preeti; O'Neal, Wesley T; Davies, Stephen W; Crane, Patricia B; Anderson, Ethan J; Kindell, Linda C; Landrine, Hope; O'Neal, Jason B; Alwair, Hazaim; Kypson, Alan P; Nifong, Wiley L; Chitwood, W Randolph

    2015-09-01

    Conditional survival is defined as the probability of surviving an additional number of years beyond that already survived. The aim of this study was to compute conditional survival in patients who received a robotically assisted, minimally invasive mitral valve repair procedure (RMVP). Patients who received RMVP with annuloplasty band from May 2000 through April 2011 were included. A 5- and 10-year conditional survival model was computed using a multivariable product-limit method. Non-smoking men (≤65 years) who presented in sinus rhythm had a 96% probability of surviving at least 10 years if they survived their first year following surgery. In contrast, recent female smokers (>65 years) with preoperative atrial fibrillation only had an 11% probability of surviving beyond 10 years if alive after one year post-surgery. In the context of an increasingly managed healthcare environment, conditional survival provides useful information for patients needing to make important treatment decisions, physicians seeking to select patients most likely to benefit long-term following RMVP, and hospital administrators needing to comparatively assess the life-course economic value of high-tech surgical procedures.

  9. Three dimensional computed tomography lung modeling is useful in simulation and navigation of lung cancer surgery.

    PubMed

    Ikeda, Norihiko; Yoshimura, Akinobu; Hagiwara, Masaru; Akata, Soichi; Saji, Hisashi

    2013-01-01

    The number of minimally invasive operations, such as video-assisted thoracoscopic surgery (VATS) lobectomy or segmentectomy, has enormously increased in recent years. These operations require extreme knowledge of the anatomy of pulmonary vessels and bronchi in each patient, and surgeons must carefully dissect the branches of pulmonary vessels during operation. Thus, foreknowledge of the anatomy of each patient would greatly contribute to the safety and accuracy of the operation. The development of multi-detector computed tomography (MDCT) has promoted three dimensional (3D) images of lung structures. It is possible to see the vascular and bronchial structures from the view of the operator; therefore, it is employed for preoperative simulation as well as navigation during operation. Due to advances in software, even small vessels can be accurately imaged, which is useful in performing segmentectomy. Surgical simulation and navigation systems based on high quality 3D lung modeling, including vascular and bronchial structures, can be used routinely to enhance the safety operation, education of junior staff, as well as providing a greater sense of security to the operators.

  10. Cost-effectiveness of robotic-assisted laparoscopic procedures in urologic surgery in the USA.

    PubMed

    Sleeper, Joshua; Lotan, Yair

    2011-01-01

    New technologies such as robotic-assisted surgery are constantly introduced clinically without a complete understanding of benefits and costs. This article will discuss general concepts of health economics and apply them to the application of robotic-assisted surgery to urologic procedures. Utilization of robotic surgery has increased dramatically in recent years. This has been most dramatic in the treatment of prostate cancer. The robot adds significant costs from acquisition, maintenance and recurrent instrument costs. These added costs, thus far, have not been associated with significant improvement in outcomes over 'pure' laparoscopy or open procedures. In order for the robot to be cost effective, there needs to be an improvement in efficacy over alternative approaches, and a decrease in costs of the robot or instrumentation. Robotic surgery has not been found to be cost effective in urology. Future studies may yet reveal indirect benefits that are not yet obvious.

  11. 3D force control for robotic-assisted beating heart surgery based on viscoelastic tissue model.

    PubMed

    Liu, Chao; Moreira, Pedro; Zemiti, Nabil; Poignet, Philippe

    2011-01-01

    Current cardiac surgery faces the challenging problem of heart beating motion even with the help of mechanical stabilizer which makes delicate operation on the heart surface difficult. Motion compensation methods for robotic-assisted beating heart surgery have been proposed recently in literature, but research on force control for such kind of surgery has hardly been reported. Moreover, the viscoelasticity property of the interaction between organ tissue and robotic instrument further complicates the force control design which is much easier in other applications by assuming the interaction model to be elastic (industry, stiff object manipulation, etc.). In this work, we present a three-dimensional force control method for robotic-assisted beating heart surgery taking into consideration of the viscoelastic interaction property. Performance studies based on our D2M2 robot and 3D heart beating motion information obtained through Da Vinci™ system are provided.

  12. Robotic surgery: current perceptions and the clinical evidence.

    PubMed

    Ahmad, Arif; Ahmad, Zoha F; Carleton, Jared D; Agarwala, Ashish

    2017-01-01

    It appears that a discrepancy exists between the perception of robotic-assisted surgery (RAS) and the current clinical evidence regarding robotic-assisted surgery among patients, healthcare providers, and hospital administrators. The purpose of this study was to assess whether or not such a discrepancy exists. We administered survey questionnaires via face-to-face interviews with surgical patients (n = 101), healthcare providers (n = 58), and senior members of hospital administration (n = 6) at a community hospital that performs robotic surgery. The respondents were asked about their perception regarding the infection rate, operative time, operative blood loss, incision size, cost, length of hospital stay (LOS), risk of complications, precision and accuracy, tactile sensation, and technique of robotic-assisted surgery as compared with conventional laparoscopic surgery. We then performed a comprehensive literature review to assess whether or not these perceptions could be corroborated with clinical evidence. The majority of survey respondents perceived RAS as modality to decrease infection rate, increase operative time, decrease operative blood loss, smaller incision size, a shorter LOS, and a lower risk of complications, while increasing the cost. Respondents also believed that robotic surgery provides greater precision, accuracy, and tactile sensation, while improving intra-operative access to organs. A comprehensive literature review found little-to-no clinical evidence that supported the respondent's favorable perceptions of robotic surgery except for the increased costs, and precision and accuracy of the robotic-assisted technique. There is a discrepancy between the perceptions of robotic surgery and the clinical evidence among patients, healthcare providers, and hospital administrators surveyed.

  13. Robot-assisted partial nephrectomy: Superiority over laparoscopic partial nephrectomy.

    PubMed

    Shiroki, Ryoichi; Fukami, Naohiko; Fukaya, Kosuke; Kusaka, Mamoru; Natsume, Takahiro; Ichihara, Takashi; Toyama, Hiroshi

    2016-02-01

    Nephron-sparing surgery has been proven to positively impact the postoperative quality of life for the treatment of small renal tumors, possibly leading to functional improvements. Laparoscopic partial nephrectomy is still one of the most demanding procedures in urological surgery. Laparoscopic partial nephrectomy sometimes results in extended warm ischemic time and severe complications, such as open conversion, postoperative hemorrhage and urine leakage. Robot-assisted partial nephrectomy exploits the advantages offered by the da Vinci Surgical System to laparoscopic partial nephrectomy, equipped with 3-D vision and a better degree in the freedom of surgical instruments. The introduction of the da Vinci Surgical System made nephron-sparing surgery, specifically robot-assisted partial nephrectomy, safe with promising results, leading to the shortening of warm ischemic time and a reduction in perioperative complications. Even for complex and challenging tumors, robotic assistance is expected to provide the benefit of minimally-invasive surgery with safe and satisfactory renal function. Warm ischemic time is the modifiable factor during robot-assisted partial nephrectomy to affect postoperative kidney function. We analyzed the predictive factors for extended warm ischemic time from our robot-assisted partial nephrectomy series. The surface area of the tumor attached to the kidney parenchyma was shown to significantly affect the extended warm ischemic time during robot-assisted partial nephrectomy. In cases with tumor-attached surface area more than 15 cm(2) , we should consider switching robot-assisted partial nephrectomy to open partial nephrectomy under cold ischemia if it is imperative. In Japan, a nationwide prospective study has been carried out to show the superiority of robot-assisted partial nephrectomy to laparoscopic partial nephrectomy in improving warm ischemic time and complications. By facilitating robotic technology, robot-assisted partial nephrectomy will be more frequently carried out as a safe, effective and minimally-invasive nephron-sparing surgery procedure. © 2015 The Japanese Urological Association.

  14. The education, role, distribution, and compensation of physician assistants in orthopedic surgery.

    PubMed

    Chalupa, Robyn L; Hooker, Roderick S

    2016-05-01

    Physician assistants (PAs) have worked alongside surgeons since the 1970s, yet little is known about their postgraduate education, roles, distribution, and compensation. In 2015, an estimated 8,900 PAs were employed in orthopedics (9.4% of all clinically active PAs in the United States). This study analyzed surveys undertaken by Physician Assistants in Orthopaedic Surgery (PAOS) from 2009 to 2015 and found that most PAs working in orthopedics (85%) reported regularly assisting in surgery. Demand for PAs in orthopedics is expected to grow because of population growth, increasing incidence of musculoskeletal conditions, shortages of surgeons, and changing technology. Improved data acquisition and more detailed analyses are needed to better understand the nature of this specialized workforce.

  15. Laser assisted robotic surgery in cornea transplantation

    NASA Astrophysics Data System (ADS)

    Rossi, Francesca; Micheletti, Filippo; Magni, Giada; Pini, Roberto; Menabuoni, Luca; Leoni, Fabio; Magnani, Bernardo

    2017-03-01

    Robotic surgery is a reality in several surgical fields, such as in gastrointestinal surgery. In ophthalmic surgery the required high spatial precision is limiting the application of robotic system, and even if several attempts have been designed in the last 10 years, only some application in retinal surgery were tested in animal models. The combination of photonics and robotics can really open new frontiers in minimally invasive surgery, improving the precision, reducing tremor, amplifying scale of motion, and automating the procedure. In this manuscript we present the preliminary results in developing a vision guided robotic platform for laser-assisted anterior eye surgery. The robotic console is composed by a robotic arm equipped with an "end effector" designed to deliver laser light to the anterior corneal surface. The main intended application is for laser welding of corneal tissue in laser assisted penetrating keratoplasty and endothelial keratoplasty. The console is equipped with an integrated vision system. The experiment originates from a clear medical demand in order to improve the efficacy of different surgical procedures: when the prototype will be optimized, other surgical areas will be included in its application, such as neurosurgery, urology and spinal surgery.

  16. New 3D model for dynamics modeling

    NASA Astrophysics Data System (ADS)

    Perez, Alain

    1994-05-01

    The wrist articulation represents one of the most complex mechanical systems of the human body. It is composed of eight bones rolling and sliding along their surface and along the faces of the five metacarpals of the hand and the two bones of the arm. The wrist dynamics are however fundamental for the hand movement, but it is so complex that it still remains incompletely explored. This work is a part of a new concept of computer-assisted surgery, which consists in developing computer models to perfect surgery acts by predicting their consequences. The modeling of the wrist dynamics are based first on the static model of its bones in three dimensions. This 3D model must optimise the collision detection procedure which is the necessary step to estimate the physical contact constraints. As many other possible computer vision models do not fit with enough precision to this problem, a new 3D model has been developed thanks to the median axis of the digital distance map of the bones reconstructed volume. The collision detection procedure is then simplified for contacts are detected between spheres. The experiment of this original 3D dynamic model products realistic computer animation images of solids in contact. It is now necessary to detect ligaments on digital medical images and to model them in order to complete a wrist model.

  17. Mandibular reconstruction after cancer: an in-house approach to manufacturing cutting guides.

    PubMed

    Bosc, R; Hersant, B; Carloni, R; Niddam, J; Bouhassira, J; De Kermadec, H; Bequignon, E; Wojcik, T; Julieron, M; Meningaud, J-P

    2017-01-01

    The restoration of mandibular bone defects after cancer can be facilitated by computer-assisted preoperative planning. The aim of this study was to assess an in-house manufacturing approach to customized cutting guides for use in the reconstruction of the mandible with osteocutaneous free flaps. A retrospective cohort study was performed, involving 18 patients who underwent mandibular reconstruction with a fibula free flap at three institutions during the period July 2012 to March 2015. A single surgeon designed and manufactured fibula and mandible cutting guides using a computer-aided design process and three-dimensional (3D) printing technology. The oncological outcomes, production parameters, and quality of the reconstructions performed for each patient were recorded. Computed tomography scans were acquired after surgery, and these were compared with the preoperative 3D models. Eighteen consecutive patients with squamous cell carcinoma underwent surgery and then reconstruction using this customized in-house surgical approach. The lengths of the fibula bone segments and the angle measurements in the simulations were similar to those of the postoperative volume rendering (P=0.61). The ease of access to 3D printing technology has enabled the computer-aided design and manufacturing of customized cutting guides for oral cancer treatment without the need for input from external laboratories. Copyright © 2016 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  18. Patient body image, self-esteem, and cosmetic results of minimally invasive robotic cardiac surgery.

    PubMed

    İyigün, Taner; Kaya, Mehmet; Gülbeyaz, Sevil Özgül; Fıstıkçı, Nurhan; Uyanık, Gözde; Yılmaz, Bilge; Onan, Burak; Erkanlı, Korhan

    2017-03-01

    Patient-reported outcome measures reveal the quality of surgical care from the patient's perspective. We aimed to compare body image, self-esteem, hospital anxiety and depression, and cosmetic outcomes by using validated tools between patients undergoing robot-assisted surgery and those undergoing conventional open surgery. This single-center, multidisciplinary, randomized, prospective study of 62 patients who underwent cardiac surgery was conducted at Hospital from May 2013 to January 2015. The patients were divided into two groups: the robotic group (n = 33) and the open group (n = 29). The study employed five different tools to assess body image, self-esteem, and overall patient-rated scar satisfaction. There were statistically significant differences between the groups in terms of self-esteem scores (p = 0.038), body image scores (p = 0.026), overall Observer Scar Assessment Scale (p = 0.013), and overall Patient Scar Assessment Scale (p = 0.036) scores in favor of the robotic group during the postoperative period. Robot-assisted surgery protected the patient's body image and self-esteem, while conventional open surgery decreased these levels but without causing pathologies. Preoperative depression and anxiety level was reduced by both robot-assisted surgery and conventional open surgery. The groups did not significantly differ on Patient Satisfaction Scores and depression/anxiety scores. The results of this study clearly demonstrated that a minimally invasive approach using robotic-assisted surgery has advantages in terms of body image, self-esteem, and cosmetic outcomes over the conventional approach in patients undergoing cardiac surgery. Copyright © 2017 IJS Publishing Group Ltd. Published by Elsevier Ltd. All rights reserved.

  19. Radiographic methods of wear analysis in total hip arthroplasty.

    PubMed

    Rahman, Luthfur; Cobb, Justin; Muirhead-Allwood, Sarah

    2012-12-01

    Polyethylene wear is an important factor in failure of total hip arthroplasty (THA). With increasing numbers of THAs being performed worldwide, particularly in younger patients, the burden of failure and revision arthroplasty is increasing, as well, along with associated costs and workload. Various radiographic methods of measuring polyethylene wear have been developed to assist in deciding when to monitor patients more closely and when to consider revision surgery. Radiographic methods that have been developed to measure polyethylene wear include manual and computer-assisted plain radiography, two- and three-dimensional techniques, and radiostereometric analysis. Some of these methods are important in both clinical and research settings. CT has the potential to provide additional information on component orientation and enables assessment of periprosthetic osteolysis, which is an important consequence of polyethylene wear.

  20. Robot-assisted ligation of bronchial artery could be an alternative to embolization.

    PubMed

    Pochulu, Bruno; Sarsam, Omar; Peillon, Christophe; Baste, Jean-Marc

    2018-03-01

    A 37-year-old patient presented with a self-limiting episode of moderate haemoptysis. Contrast-enhanced chest computed tomography showed a tortuous and dilated right bronchial artery arising from the descending aorta at the level of T6. Therapeutic angiography was attempted, but in the presence of spinal artery arising from the bronchial artery in question, selective embolization was contraindicated due to risk of spinal cord ischaemia. After a multidisciplinary meeting, it was decided to attempt surgery to ligate this pathological artery. We performed minimally invasive robot-assisted ligation of this pathological artery. The postoperative course was uneventful with good clinical and radiological outcome at 3-month follow-up. A minimally invasive approach provides a real alternative to embolization and could be a therapeutic option.

  1. Integration of computer-assisted fracture reduction system and a hybrid 3-DOF-RPS mechanism for assisting the orthopedic surgery

    NASA Astrophysics Data System (ADS)

    Irwansyah; Sinh, N. P.; Lai, J. Y.; Essomba, T.; Asbar, R.; Lee, P. Y.

    2018-02-01

    In this paper, we present study to integrate virtual fracture bone reduction simulation tool with a novel hybrid 3-DOF-RPS external fixator to relocate back bone fragments into their anatomically original position. A 3D model of fractured bone was reconstructed and manipulated using 3D design and modeling software, PhysiGuide. The virtual reduction system was applied to reduce a bilateral femoral shaft fracture type 32-A3. Measurement data from fracture reduction and fixation stages were implemented to manipulate the manipulator pose in patient’s clinical case. The experimental result presents that by merging both of those techniques will give more possibilities to reduce virtual bone reduction time, improve facial and shortest healing treatment.

  2. Haptic computer-assisted patient-specific preoperative planning for orthopedic fractures surgery.

    PubMed

    Kovler, I; Joskowicz, L; Weil, Y A; Khoury, A; Kronman, A; Mosheiff, R; Liebergall, M; Salavarrieta, J

    2015-10-01

    The aim of orthopedic trauma surgery is to restore the anatomy and function of displaced bone fragments to support osteosynthesis. For complex cases, including pelvic bone and multi-fragment femoral neck and distal radius fractures, preoperative planning with a CT scan is indicated. The planning consists of (1) fracture reduction-determining the locations and anatomical sites of origin of the fractured bone fragments and (2) fracture fixation-selecting and placing fixation screws and plates. The current bone fragment manipulation, hardware selection, and positioning processes based on 2D slices and a computer mouse are time-consuming and require a technician. We present a novel 3D haptic-based system for patient-specific preoperative planning of orthopedic fracture surgery based on CT scans. The system provides the surgeon with an interactive, intuitive, and comprehensive, planning tool that supports fracture reduction and fixation. Its unique features include: (1) two-hand haptic manipulation of 3D bone fragments and fixation hardware models; (2) 3D stereoscopic visualization and multiple viewing modes; (3) ligaments and pivot motion constraints to facilitate fracture reduction; (4) semiautomatic and automatic fracture reduction modes; and (5) interactive custom fixation plate creation to fit the bone morphology. We evaluate our system with two experimental studies: (1) accuracy and repeatability of manual fracture reduction and (2) accuracy of our automatic virtual bone fracture reduction method. The surgeons achieved a mean accuracy of less than 1 mm for the manual reduction and 1.8 mm (std [Formula: see text] 1.1 mm) for the automatic reduction. 3D haptic-based patient-specific preoperative planning of orthopedic fracture surgery from CT scans is useful and accurate and may have significant advantages for evaluating and planning complex fractures surgery.

  3. Robotic technology in surgery: current status in 2008.

    PubMed

    Murphy, Declan G; Hall, Rohan; Tong, Raymond; Goel, Rajiv; Costello, Anthony J

    2008-12-01

    There is increasing patient and surgeon interest in robotic-assisted surgery, particularly with the proliferation of da Vinci surgical systems (Intuitive Surgical, Sunnyvale, CA, USA) throughout the world. There is much debate over the usefulness and cost-effectiveness of these systems. The currently available robotic surgical technology is described. Published data relating to the da Vinci system are reviewed and the current status of surgical robotics within Australia and New Zealand is assessed. The first da Vinci system in Australia and New Zealand was installed in 2003. Four systems had been installed by 2006 and seven systems are currently in use. Most of these are based in private hospitals. Technical advantages of this system include 3-D vision, enhanced dexterity and improved ergonomics when compared with standard laparoscopic surgery. Most procedures currently carried out are urological, with cardiac, gynaecological and general surgeons also using this system. The number of patients undergoing robotic-assisted surgery in Australia and New Zealand has increased fivefold in the past 4 years. The most common procedure carried out is robotic-assisted laparoscopic radical prostatectomy. Published data suggest that robotic-assisted surgery is feasible and safe although the installation and recurring costs remain high. There is increasing acceptance of robotic-assisted surgery, especially for urological procedures. The da Vinci surgical system is becoming more widely available in Australia and New Zealand. Other surgical specialties will probably use this technology. Significant costs are associated with robotic technology and it is not yet widely available to public patients.

  4. Training and learning robotic surgery, time for a more structured approach: a systematic review.

    PubMed

    Schreuder, H W R; Wolswijk, R; Zweemer, R P; Schijven, M P; Verheijen, R H M

    2012-01-01

    Robotic assisted laparoscopic surgery is growing rapidly and there is an increasing need for a structured approach to train future robotic surgeons. To review the literature on training and learning strategies for robotic assisted laparoscopic surgery. A systematic search of MEDLINE, EMBASE, the Cochrane Library and the Journal of Robotic Surgery was performed. We included articles concerning training, learning, education and teaching of robotic assisted laparoscopic surgery in any specialism. Two authors independently selected articles to be included. We categorised the included articles into: training modalities, learning curve, training future surgeons, curriculum design and implementation. We included 114 full text articles. Training modalities such as didactic training, skills training (dry lab, virtual reality, animal or cadaver models), case observation, bedside assisting, proctoring and the mentoring console can be used for training in robotic assisted laparoscopic surgery. Several training programmes in general and specific programmes designed for residents, fellows and surgeons are described in the literature. We provide guidelines for development of a structured training programme. Robotic surgical training consists of system training and procedural training. System training should be formally organised and should be competence based, instead of time based. Virtual reality training will play an import role in the near future. Procedural training should be organised in a stepwise approach with objective assessment of each step. This review aims to facilitate and improve the implementation of structured robotic surgical training programmes. © 2011 The Authors BJOG An International Journal of Obstetrics and Gynaecology © 2011 RCOG.

  5. Cosmetic ear surgery

    MedlinePlus

    ... ear reduction. In: Rubin JP, Neligan PC, eds. Plastic Surgery: Volume 2: Aesthetic Surgery . 4th ed. Philadelphia, ... Tang Ho, MD, Assistant Professor, Division of Facial Plastic and Reconstructive Surgery, Department of Otolaryngology – Head and ...

  6. Ergonomic analysis of primary and assistant surgical roles.

    PubMed

    Zihni, Ahmed M; Cavallo, Jaime A; Ray, Shuddhadeb; Ohu, Ikechukwu; Cho, Sohyung; Awad, Michael M

    2016-06-15

    Laparoscopic surgery is associated with a high degree of ergonomic stress. However, the stress associated with surgical assisting is not known. In this study, we compare the ergonomic stress associated with primary and assistant surgical roles during laparoscopic surgery. We hypothesize that higher ergonomic stress will be detected in the primary operating surgeon when compared with the surgical assistant. One right-hand dominant attending surgeon performed 698 min of laparoscopic surgery over 13 procedures (222 min primary and 476 min assisting), whereas electromyography data were collected from bilateral biceps, triceps, deltoids, and trapezius muscles. Data were analyzed in 1-min segments. Average muscle activation as quantified by maximal voluntary contraction (%MVC) was calculated for each muscle group during primary surgery and assisting. We compared mean %MVC values with unpaired t-tests. Activation of right (R) biceps and triceps muscle groups is significantly elevated while operating when compared with assisting (R biceps primary: 5.47 ± 0.21 %MVC, assistant: 3.93 ± 0.11, P < 0.001; R triceps primary: 6.53 ± 0.33 %MVC, assistant: 5.48 ± 0.18, P = 0.002). Mean activation of the left trapezius muscle group is elevated during assisting (primary: 4.33 ± 0.26 %MVC, assistant: 5.70 ± 0.40, P = 0.024). No significance difference was noted in the other muscle groups (R deltoid, R trapezius, left [L] biceps, L triceps, and L deltoid). We used surface electromyography to quantify ergonomic differences between operating and assisting. Surgical assisting was associated with similar and occasionally higher levels of muscle activation compared with primary operating. These findings suggest that surgical assistants face significant ergonomic stress, just as operating surgeons do. Steps must be taken to recognize and mitigate this stress in both operating surgeons and assistants. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. Low-cost biportal endoscopic surgery for primary spontaneous pneumothorax

    PubMed Central

    Luo, Yuzhong; Yang, Xiaoping; Mo, Shaoxiong; Wu, Jun; Wei, Yitong

    2015-01-01

    Background Like many other countries, including the United States, China faces the problem of rising health care costs, which have become a heavy burden on the state and individuals. Endoscopic surgery offers many benefits. However, the need for more expensive endoscopic consumables brings further high medical costs. Therefore, the development of video-assisted thoracic surgery with no disposable consumables will help to control medical cost escalation. Methods Between October 2011 and September 2014, a series of 66 patients with primary spontaneous pneumothorax underwent hand ligation of blebs under biportal video-assisted thoracoscopic surgery or bullectomy with stapler during triportal video-assisted thoracoscopic surgery. After treatment of blebs, pleural abrasion was performed with an electrocautery cleaning pad. Results Compared with the group treated by bullectomy with stapler, we found a significant reduction in postoperative costs in the group with bleb ligation. There was no difference in operating time, chest tube drainage, and postoperative stay between the two groups. The follow-up period varied from 1 to 35 months and six cases of recurrence were noted. Conclusions The technique that we described appears to offer better economic results than bullectomy with a stapler under three-port video-assisted thoracoscopic surgery for treating primary spontaneous. The clinical outcomes are similar. PMID:25973237

  8. Cost-Benefit Performance Simulation of Robot-Assisted Thoracic Surgery As Required for Financial Viability under the 2016 Revised Reimbursement Paradigm of the Japanese National Health Insurance System.

    PubMed

    Kajiwara, Naohiro; Kato, Yasufumi; Hagiwara, Masaru; Kakihana, Masatoshi; Ohira, Tatsuo; Kawate, Norihiko; Ikeda, Norihiko

    2018-04-20

    To discuss the cost-benefit performance (CBP) and establish a medical fee system for robotic-assisted thoracic surgery (RATS) under the Japanese National Health Insurance System (JNHIS), which is a system not yet firmly established. All management steps for RATS are identical, such as preoperative and postoperative management. This study examines the CBP based on medical fees of RATS under the JNHIS introduced in 2016. Robotic-assisted laparoscopic prostatectomy (RALP) and robotic-assisted partial nephrectomy (RAPN) now receive insurance reimbursement under the category of use of support devices for endoscopic surgery ($5420 and $3485, respectively). If the same standard amount were to be applied to RATS, institutions would need to perform at least 150 or 300 procedures thoracic operation per year to show a positive CBP ($317 per procedure as same of RALP and $130 per procedure as same of RAPN, respectively). Robotic surgery in some areas receives insurance reimbursement for its "supportive" use for endoscopic surgery as for RALP and RAPN. However, at present, it is necessary to perform da Vinci Surgical System Si (dVSi) surgery at least 150-300 times in a year in a given institution to prevent a deficit in income.

  9. Robotic-assisted surgery in gynecologic oncology.

    PubMed

    Sinno, Abdulrahman K; Fader, Amanda N

    2014-10-01

    The quest for improved patient outcomes has been a driving force for adoption of novel surgical innovations across surgical subspecialties. Gynecologic oncology is one such surgical discipline in which minimally invasive surgery has had a robust and evolving role in defining standards of care. Robotic-assisted surgery has developed during the past two decades as a more technologically advanced form of minimally invasive surgery in an effort to mitigate the limitations of conventional laparoscopy and improved patient outcomes. Robotically assisted technology offers potential advantages that include improved three-dimensional stereoscopic vision, wristed instruments that improve surgeon dexterity, and tremor canceling software that improves surgical precision. These technological advances may allow the gynecologic oncology surgeon to perform increasingly radical oncologic surgeries in complex patients. However, the platform is not without limitations, including high cost, lack of haptic feedback, and the requirement for additional training to achieve competence. This review describes the role of robotic-assisted surgery in the management of endometrial, cervical, and ovarian cancer, with an emphasis on comparison with laparotomy and conventional laparoscopy. The literature on novel robotic innovations, special patient populations, cost effectiveness, and fellowship training is also appraised critically in this regard. Copyright © 2014 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  10. Integrated Artificial Intelligence Approaches for Disease Diagnostics.

    PubMed

    Vashistha, Rajat; Chhabra, Deepak; Shukla, Pratyoosh

    2018-06-01

    Mechanocomputational techniques in conjunction with artificial intelligence (AI) are revolutionizing the interpretations of the crucial information from the medical data and converting it into optimized and organized information for diagnostics. It is possible due to valuable perfection in artificial intelligence, computer aided diagnostics, virtual assistant, robotic surgery, augmented reality and genome editing (based on AI) technologies. Such techniques are serving as the products for diagnosing emerging microbial or non microbial diseases. This article represents a combinatory approach of using such approaches and providing therapeutic solutions towards utilizing these techniques in disease diagnostics.

  11. Oophorectomy (Ovary Removal Surgery)

    MedlinePlus

    ... also be robotically assisted in certain cases. During robotic surgery, the surgeon watches a 3-D monitor and ... weeks after surgery. Those who undergo laparoscopic or robotic surgery may return to full activity sooner — as early ...

  12. ACOG Technology Assessment in Obstetrics and Gynecology No. 6: Robot-assisted surgery.

    PubMed

    2009-11-01

    The field of robotic surgery is developing rapidly, but experience with this technology is currently limited. In response to increasing interest in robotics technology, the Committee on Gynecologic Practice's Technology Assessment was developed to describe the robotic surgical system,potential advantages and disadvantages, gynecologic applications, and the current state of the evidence. Randomized trials comparing robot-assisted surgery with traditional laparoscopic, vaginal, or abdominal surgery are needed to evaluate long-term clinical outcomes and cost-effectiveness, as well as to identify the best applications of this technology.

  13. [Prof. Michiharu Matsuoka, founder of the Department of Orthopaedic Surgery, Kyoto University, and his achievements in orthopaedic surgery in the Meiji Era of Japan (part 1: establishment of the department)].

    PubMed

    Hirotani, Hayato

    2005-09-01

    The Department of Orthopaedic and Musculoskeletal Surgery, Graduate School of Medicine, Kyoto University (formerly the Department of Orthopaedic Surgery, Kyoto Medical School, Kyoto Imperial University) was founded by Imperial Ordinance, Article No. 89 issued on April 23, 1906. On May 4, 1906, Dr. Shinichiro Asahara, Assistant Professor of the Department of Surgery, was appointed as the first director of the Department of Orthopaedic Surgery, Kyoto Medical School, Kyoto Imperial University. Dr. Michiharu Matsuoka, Assistant Doctor of the Department of Surgery, Tokyo Medical School, Imperial University of Tokyo, was appointed Assistant Professor of Surgery, Kyoto Medical School, Kyoto Imperial University in March 1901. From August 1903 to May 1906, he studied orthopaedic surgery in Germany and returned on May 5, 1906. Dr. Matsuoka was appointed as the director and chief of the Department on May 13, 1906 and took over Dr. Asahara's position. On June 18, 1906, Dr. Matsuoka started his clinic and began giving lectures on orthopaedic surgery. This was the first department of orthopaedic surgery among the Japanese medical schools. Dr. Matsuoka was appointed as Professor in 1907. He had to overcome several obstacles to establish the medical department of a new discipline that had never existed in Japanese medical schools. This article discusses Dr. Matsuoka's contributions to establishing and developing orthopaedic surgery in Japan in the Meiji-era.

  14. Bridging the gap between formal and experience-based knowledge for context-aware laparoscopy.

    PubMed

    Katić, Darko; Schuck, Jürgen; Wekerle, Anna-Laura; Kenngott, Hannes; Müller-Stich, Beat Peter; Dillmann, Rüdiger; Speidel, Stefanie

    2016-06-01

    Computer assistance is increasingly common in surgery. However, the amount of information is bound to overload processing abilities of surgeons. We propose methods to recognize the current phase of a surgery for context-aware information filtering. The purpose is to select the most suitable subset of information for surgical situations which require special assistance. We combine formal knowledge, represented by an ontology, and experience-based knowledge, represented by training samples, to recognize phases. For this purpose, we have developed two different methods. Firstly, we use formal knowledge about possible phase transitions to create a composition of random forests. Secondly, we propose a method based on cultural optimization to infer formal rules from experience to recognize phases. The proposed methods are compared with a purely formal knowledge-based approach using rules and a purely experience-based one using regular random forests. The comparative evaluation on laparoscopic pancreas resections and adrenalectomies employs a consistent set of quality criteria on clean and noisy input. The rule-based approaches proved best with noisefree data. The random forest-based ones were more robust in the presence of noise. Formal and experience-based knowledge can be successfully combined for robust phase recognition.

  15. Medical three-dimensional printing opens up new opportunities in cardiology and cardiac surgery.

    PubMed

    Bartel, Thomas; Rivard, Andrew; Jimenez, Alejandro; Mestres, Carlos A; Müller, Silvana

    2018-04-14

    Advanced percutaneous and surgical procedures in structural and congenital heart disease require precise pre-procedural planning and continuous quality control. Although current imaging modalities and post-processing software assists with peri-procedural guidance, their capabilities for spatial conceptualization remain limited in two- and three-dimensional representations. In contrast, 3D printing offers not only improved visualization for procedural planning, but provides substantial information on the accuracy of surgical reconstruction and device implantations. Peri-procedural 3D printing has the potential to set standards of quality assurance and individualized healthcare in cardiovascular medicine and surgery. Nowadays, a variety of clinical applications are available showing how accurate 3D computer reformatting and physical 3D printouts of native anatomy, embedded pathology, and implants are and how they may assist in the development of innovative therapies. Accurate imaging of pathology including target region for intervention, its anatomic features and spatial relation to the surrounding structures is critical for selecting optimal approach and evaluation of procedural results. This review describes clinical applications of 3D printing, outlines current limitations, and highlights future implications for quality control, advanced medical education and training.

  16. [Two cases of curative resection by laparoscopic surgery following preoperative chemotherapy with bevacizumab for locally advanced colon cancer].

    PubMed

    Sakaguchi, Masazumi; Kan, Takatsugu; Tsubono, Michihiko; Kii, Eiji

    2014-04-01

    Here we report 2 cases of curative resection following preoperative chemotherapy with bevacizumab for locally advanced colon cancer. Case 1 was a 62-year-old man admitted with constipation, abdominal distention, and abdominal pain. An abdominal computed tomography(CT)scan revealed an obstructive tumor of the sigmoid colon with invasion into the bladder. A diverting colostomy was performed, and chemotherapy with mFOLFOX6(infusional 5-fluorouracil/Leucovorin+ oxaliplatin) plus bevacizumab was initiated. The tumor shrunk markedly after 6 courses of this treatment. Thereafter, laparoscopy- assisted sigmoidectomy was successfully performed. Case 2 was a 61-year-old woman admitted with diarrhea, abdominal pain, and fever. An abdominal CT scan revealed an obstructive tumor of the sigmoid colon with invasion into the ileum, uterus and retroperitoneum. A diverting colostomy was performed, and chemotherapy with XELOX(capecitabine+ oxaliplatin)plus bevacizumab was initiated. The tumor shrunk markedly after 6 courses of this treatment. Thereafter, laparoscopy- assisted sigmoidectomy was successfully performed. Both cases demonstrated partial clinical responses to chemotherapy; thus, curative resection surgeries were performed. There were no perioperative complications. Therefore, we conclude that oxaliplatin-based chemotherapy plus bevacizumab and laparoscopic resection could be very effective for locally advanced colon cancer.

  17. The first national examination of outcomes and trends in robotic surgery in the United States.

    PubMed

    Anderson, Jamie E; Chang, David C; Parsons, J Kellogg; Talamini, Mark A

    2012-07-01

    There are few population-based data describing outcomes of robotic-assisted surgery. We compared outcomes of robotic-assisted, laparoscopic, and open surgery in a nationally representative population database. A retrospective analysis of the Nationwide Inpatient Sample database from October 2008 to December 2009 was performed. We identified the most common robotic procedures by ICD-9 procedure codes and grouped them into categories by procedure type. Multivariate analyses examined mortality, length of stay (LOS), and total hospital charges, adjusting for age, race, sex, Charlson comorbidity index, and teaching hospital status. A total of 368,239 patients were identified. On adjusted analysis, compared with open, robotic-assisted laparoscopic surgery was associated with decreased odds of mortality (odds ratio = 0.1; 95% CI, 0.0-0.2; p < 0.001), decreased mean LOS (-2.4 days; 95% CI, -2.5 to 2.3; p < 0.001), and increased mean total charges in all procedures (range $3,852 to $15,329) except coronary artery bypass grafting (-$17,318; 95% CI, -34,492 to -143; p = 0.048) and valvuloplasty (not statistically significant). Compared with laparoscopic, robotic-assisted laparoscopic surgery was associated with decreased odds of mortality (odds ratio = 0.1; 95% CI, 0.0-0.6; p = 0.008), decreased LOS overall (-0.6 days; 95% CI, -0.7 to -0.5; p < 0.001), but increased LOS in prostatectomy and other kidney/bladder procedures (0.3 days; 95% CI, 0.1-0.4; p = 0.006; 0.8 days; 95% CI, 0.0-1.6; p = 0.049), and increased total charges ($1,309; 95% CI, 519-2,099; p = 0.001). Data suggest that, compared with open surgery, robotic-assisted surgery results in decreased LOS and diminished likelihood of death. However, these benefits are not as apparent when comparing robotic-assisted laparoscopic with nonrobotic laparoscopic procedures. Copyright © 2012 American College of Surgeons. Published by Elsevier Inc. All rights reserved.

  18. Solo surgery--early results of robot-assisted three-dimensional laparoscopic hysterectomy.

    PubMed

    Tuschy, Benjamin; Berlit, Sebastian; Brade, Joachim; Sütterlin, Marc; Hornemann, Amadeus

    2014-08-01

    Report of our initial experience in laparoscopic hysterectomy by a solo surgeon using a robotic camera system with three-dimensional visualisation. This novel device (Einstein Vision®, B. Braun, Aesculap AG, Tuttlingen, Germany) (EV) was used for laparoscopic supracervical hysterectomy (LASH) performed by one surgeon. Demographic data, clinical and surgical parameters were evaluated. Our first 22 cases, performed between June and November 2012, were compared with a cohort of 22 age-matched controls who underwent two-dimensional LASH performed by the same surgeon with a second surgeon assisting. Compared to standard two-dimensional laparoscopic hysterectomy, there were no significant differences regarding duration of surgery, hospital stay, blood loss or incidence of complications. The number of trocars used was significantly higher in the control group (p <.0001). All hysterectomies in the treatment group were performed without assistance of a second physician. Robot-assisted solo surgery laparoscopic hysterectomy is a feasible and safe procedure. Duration of surgery, hospital stay, blood loss, and complication rates are comparable to a conventional laparoscopic hysterectomy.

  19. High fidelity computational simulation of thrombus formation in Thoratec HeartMate II continuous flow ventricular assist device

    PubMed Central

    Wu, Wei-Tao; Yang, Fang; Wu, Jingchun; Aubry, Nadine; Massoudi, Mehrdad; Antaki, James F.

    2016-01-01

    Continuous flow ventricular assist devices (cfVADs) provide a life-saving therapy for severe heart failure. However, in recent years, the incidence of device-related thrombosis (resulting in stroke, device-exchange surgery or premature death) has been increasing dramatically, which has alarmed both the medical community and the FDA. The objective of this study was to gain improved understanding of the initiation and progression of thrombosis in one of the most commonly used cfVADs, the Thoratec HeartMate II. A computational fluid dynamics simulation (CFD) was performed using our recently updated mathematical model of thrombosis. The patterns of deposition predicted by simulation agreed well with clinical observations. Furthermore, thrombus accumulation was found to increase with decreased flow rate, and can be completely suppressed by the application of anticoagulants and/or improvement of surface chemistry. To our knowledge, this is the first simulation to explicitly model the processes of platelet deposition and thrombus growth in a continuous flow blood pump and thereby replicate patterns of deposition observed clinically. The use of this simulation tool over a range of hemodynamic, hematological, and anticoagulation conditions could assist physicians to personalize clinical management to mitigate the risk of thrombosis. It may also contribute to the design of future VADs that are less thrombogenic. PMID:27905492

  20. Towards computer-assisted TTTS: Laser ablation detection for workflow segmentation from fetoscopic video.

    PubMed

    Vasconcelos, Francisco; Brandão, Patrick; Vercauteren, Tom; Ourselin, Sebastien; Deprest, Jan; Peebles, Donald; Stoyanov, Danail

    2018-06-27

    Intrauterine foetal surgery is the treatment option for several congenital malformations. For twin-to-twin transfusion syndrome (TTTS), interventions involve the use of laser fibre to ablate vessels in a shared placenta. The procedure presents a number of challenges for the surgeon, and computer-assisted technologies can potentially be a significant support. Vision-based sensing is the primary source of information from the intrauterine environment, and hence, vision approaches present an appealing approach for extracting higher level information from the surgical site. In this paper, we propose a framework to detect one of the key steps during TTTS interventions-ablation. We adopt a deep learning approach, specifically the ResNet101 architecture, for classification of different surgical actions performed during laser ablation therapy. We perform a two-fold cross-validation using almost 50 k frames from five different TTTS ablation procedures. Our results show that deep learning methods are a promising approach for ablation detection. To our knowledge, this is the first attempt at automating photocoagulation detection using video and our technique can be an important component of a larger assistive framework for enhanced foetal therapies. The current implementation does not include semantic segmentation or localisation of the ablation site, and this would be a natural extension in future work.

  1. [Initial experience in robot-assisted colorectal surgery in Mexico].

    PubMed

    Villanueva-Sáenz, Eduardo; Ramírez-Ramírez, Moisés Marino; Zubieta-O'Farrill, Gregorio; García-Hernández, Luis

    Colorectal surgery has advanced notably since the introduction of the mechanical suture and the minimally invasive approach. Robotic surgery began in order to satisfy the needs of the patient-doctor relationship, and migrated to the area of colorectal surgery. An initial report is presented on the experience of managing colorectal disease using robot-assisted surgery, as well as an analysis of the current role of this platform. A retrospective study was conducted in order to review five patients with colorectal disease operated using a robot-assisted technique over one year in the initial phase of the learning curve. Gender, age, diagnosis and surgical indication, surgery performed, surgical time, conversion, bleeding, post-operative complications, and hospital stay, were analysed and described. A literature review was performed on the role of robotic assisted surgery in colorectal disease and cancer. The study included 5 patients, 3 men and 2 women, with a mean age of 62.2 years. Two of them were low anterior resections with colorectal primary anastomoses, one of them extended with a loop protection ileostomy, a Frykman-Goldberg procedure, and two left hemicolectomies with primary anastomoses. The mean operating time was 6hours and robot-assisted 4hours 20minutes. There were no conversions and the mean hospital stay was 5 days. This technology is currently being used worldwide in different surgical centres because of its advantages that have been clinically demonstrated by various studies. We report the first colorectal surgical cases in Mexico, with promising results. There is enough evidence to support and recommend the use of this technology as a viable and safe option. Copyright © 2016 Academia Mexicana de Cirugía A.C. Publicado por Masson Doyma México S.A. All rights reserved.

  2. Does Low-Field Intraoperative Magnetic Resonance Improve the Results of Endoscopic Pituitary Surgery? Experience of the Implementation of a New Device in a Referral Center.

    PubMed

    García, Sergio; Reyes, Luis; Roldán, Pedro; Torales, Jorge; Halperin, Irene; Hanzu, Felicia; Langdon, Cristobal; Alobid, Isam; Enseñat, Joaquim

    2017-06-01

    To assess the contribution of low-field intraoperative magnetic resonance (iMRI) to endoscopic pituitary surgery. We analyzed a prospective series of patients undergoing endoscopic endonasal surgery for pituitary macroadenomas assisted with a low-field iMRI (PoleStarN30, 0.15 T [Medtronic]). Clinical, radiologic, and surgical variables were analyzed and compared with our fully endoscopic historic cohort operated on without iMRI assistance. A bibliographic review of pituitary surgery assisted with iMRI was conducted. Thirty patients (57% female; mean age, 55 years) were prospectively analyzed. The most frequent tumor subtype was nonfunctioning macroadenoma (50%). The average Knosp grade was 2.3 and mean tumor size was 18 mm. Surgical and positioning time were 102 and 47 minutes, respectively. Hospital stay and complication rates were similar to our historical cohort for pituitary surgery. Mean follow-up was 10 months. Complete resection (CR) was achieved in 83% of patients. Seven patients (23%) benefited from iMRI assistance and achieved a CR in their surgeries. All patients except 1 experienced hormonal activity remission. iMRI sensitivity and specificity was 0.8 and 1, respectively. Although not statistically significant, CR rates were globally 11.5% superior in iMRI series compared with our historical cohort. This difference was independent of cavernous sinus invasiveness grade (CR rate increased 12.5% for Knosp grade 0-2 and 8.1% for Knosp grade 3-4). Low-field iMRI is a useful and safe assistance even in advanced surgical techniques such as endoscopy. Its contribution is limited by the intrinsic features of the tumor. Further randomized studies are required to confirm the cost-effectiveness of iMRI in pituitary surgery. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. [A case of laparoscopic surgery for a rectal carcinoid after ALTA therapy for an internal hemorrhoid].

    PubMed

    Aomatsu, Naoki; Nakamura, Masanori; Hasegawa, Tsuyoshi; Nakao, Shigetomi; Uchima, Yasutake; Aomatsu, Keiho

    2014-11-01

    We report a case of laparoscopic surgery for a rectal carcinoid after aluminum potassium and tannic acid (ALTA) therapy for an internal hemorrhoid. A 66-year-old man was admitted to our hospital because of bleeding during defecation. He was diagnosed via anoscopy with Goligher grade II internal hemorrhoids. Examination via colonoscopy revealed 2 yellowish submucosal tumors in the lower rectum that were 5mm and 10mm in diameter. A rectal carcinoid tumor was diagnosed based on histopathology. Abdominal computed tomography demonstrated no metastases to the liver or lymph nodes. First, we performed ALTA therapy for the internal hemorrhoids. Two weeks later, we performed laparoscopic-assisted low anterior resection (D2) for the rectal carcinoid. The patient was discharged without complications and has not experienced recurrence during the 2 years of follow-up care.

  4. Three-dimensional (3D)- computed tomography bronchography and angiography combined with 3D-video-assisted thoracic surgery (VATS) versus conventional 2D-VATS anatomic pulmonary segmentectomy for the treatment of non-small cell lung cancer.

    PubMed

    She, Xiao-Wei; Gu, Yun-Bin; Xu, Chun; Li, Chang; Ding, Cheng; Chen, Jun; Zhao, Jun

    2018-02-01

    Compared to the pulmonary lobe, the anatomical structure of the pulmonary segment is relatively complex and prone to variation, thus the risk and difficulty of segmentectomy is increased. We compared three-dimensional computed tomography bronchography and angiography (3D-CTBA) combined with 3D video-assisted thoracic surgery (3D-VATS) to perform segmentectomy to conventional two-dimensional (2D)-VATS for the treatment of non-small cell lung cancer (NSCLC). We retrospectively reviewed the data of randomly selected patients who underwent 3D-CTBA combined with 3D-VATS (3D-CTBA-VATS) or 2D-VATS at the Department of Thoracic Surgery, The First Affiliated Hospital of Soochow University Hospital, from January 2014 to May 2017. The operative duration of 3D group was significantly shorter than the 2D group (P < 0.05). There was no significant difference in the number of dissected lymph nodes between the two groups (P > 0.05). The extent of intraoperative bleeding and postoperative drainage in the 3D group was significantly lower than in the 2D group (P < 0.05). Chest tube duration in the 3D group was shorter than in the 2D group (P < 0.05). Incidences of pulmonary infection, atelectasis, and arrhythmia were not statistically different between the two groups (P > 0.05). However, hemoptysis and pulmonary air leakage (>3d) occurred significantly less frequently in the 3D than in the 2D group (P < 0.05). 3D-CTBA-VATS is a more accurate and smooth technique and leads to reduced intraoperative and postoperative complications. © 2018 The Authors. Thoracic Cancer published by China Lung Oncology Group and John Wiley & Sons Australia, Ltd.

  5. A Dynamic Non Energy Storing Guidance Constraint with Motion Redirection for Robot Assisted Surgery

    DTIC Science & Technology

    2016-12-01

    Abstract— Haptically enabled hands-on or tele-operated surgical robotic systems provide a unique opportunity to integrate pre- and intra... robot -assisted surgical systems aim at improving and extending human capabilities, by exploiting the advantages of robotic systems while keeping the...move during the operation. Robot -assisted beating heart surgery is an example of procedures that can benefit from dynamic constraints. Their

  6. Value of Robotically Assisted Surgery for Mitral Valve Disease

    PubMed Central

    Mihaljevic, Tomislav; Koprivanac, Marijan; Kelava, Marta; Goodman, Avi; Jarrett, Craig; Williams, Sarah J.; Gillinov, A. Marc; Bajwa, Gurjyot; Mick, Stephanie L.; Bonatti, Johannes; Blackstone, Eugene H.

    2014-01-01

    Importance The value of robotically assisted surgery for mitral valve disease is questioned because the high cost of care associated with robotic technology may outweigh its clinical benefits. Objective To investigate conditions under which benefits of robotic surgery mitigate high technology costs. Design Clinical cohort study comparing costs of robotic vs. three contemporaneous conventional surgical approaches for degenerative mitral disease. Surgery was performed from 2006–2011, and comparisons were based on intent-to-treat, with propensity-matching used to reduce selection bias. Setting Large multi-specialty academic medical center. Participants 1,290 patients aged 57±11 years, 27% women, underwent mitral repair for regurgitation from posterior leaflet prolapse. Robotic surgery was used in 473, complete sternotomy in 227, partial sternotomy in 349, and anterolateral thoracotomy in 241. Three propensity-matched groups were formed based on demographics, symptoms, cardiac and noncardiac comorbidities, valve pathophysiology, and echocardiographic measurements: robotic vs. sternotomy (n=198 pairs) vs. partial sternotomy (n=293 pairs) vs. thoracotomy (n=224 pairs). Interventions Mitral valve repair. Main Outcome Measures Cost of care, expressed as robotic capital investment, maintenance, and direct technical hospital cost, and benefit of care, based on differences in recovery time. Results Median cost of care for robotically assisted surgery exceeded the cost of alternative approaches by 27% (−5%, 68%), 32% (−6%, 70%), and 21% (−2%, 54%) (median [15th, 85th percentiles]) for complete sternotomy, partial sternotomy, and anterolateral thoracotomy, respectively. Higher operative costs were partially offset by lower postoperative costs and earlier return to work: median 35 days for robotic surgery, 49 for complete sternotomy, 56 for partial sternotomy, and 42 for anterolateral thoracotomy. Resulting net differences in cost of robotic surgery vs. the three alternatives were 16% (−15%, 55%), 16% (−19%, 51%), and 15% (−7%, 49%), respectively. Beyond a volume threshold of 55–100 robotic cases per year, confidence limits for the cost of robotic surgery broadly overlapped those of conventional approaches. Conclusions In exchange for higher procedural costs, robotically assisted mitral valve surgery offers the clinical benefit of least invasive surgery, lowest postoperative cost, and fastest return to work. The value of robotically assisted surgery comparable to conventional approaches can only be realized in high-volume centers. PMID:24848944

  7. Femtosecond laser-assisted cataract surgeries reported to the European Registry of Quality Outcomes for Cataract and Refractive Surgery: Baseline characteristics, surgical procedure, and outcomes.

    PubMed

    Lundström, Mats; Dickman, Mor; Henry, Ype; Manning, Sonia; Rosen, Paul; Tassignon, Marie-José; Young, David; Stenevi, Ulf

    2017-12-01

    To describe a large cohort of femtosecond laser-assisted cataract surgeries in terms of baseline characteristics and the related outcomes. Eighteen cataract surgery clinics in 9 European countries and Australia. Prospective multicenter case series. Data on consecutive eyes having femtosecond laser-assisted cataract surgery in the participating clinics were entered in the European Registry of Quality Outcomes for Cataract and Refractive Surgery (EUREQUO). A trained registry manager in each clinic was responsible for valid reporting to the EUREQUO. Demographics, preoperative corrected distance visual acuity (CDVA), risk factors, type of surgery, type of intraocular lens, visual outcomes, refractive outcomes, and complications were reported. Complete data were available for 3379 cases. The mean age was 64.4 years ± 10.9 (SD) and 57.8% (95% confidence interval [CI], 56.1-59.5) of the patients were women. A surgical complication was reported in 2.9% of all cases (95% CI, 2.4-3.5). The mean postoperative CDVA was 0.04 ± 0.15. logarithm of the minimum angle of resolution. A biometry prediction error (spherical equivalent) was within ±0.5 diopter in 71.8% (95% CI, 70.3-73.3) of all surgeries. Postoperative complications were reported in 3.3% (95% CI, 2.7-4.0). Patients with good preoperative CDVA had the best visual and refractive outcomes; patients with poor preoperative visual acuity had poorer outcomes. The visual and refractive outcomes of femtosecond laser-assisted cataract surgery were favorable compared with manual phacoemulsification. The outcomes were highly influenced by the preoperative visual acuity, but all preoperative CDVA groups had acceptable outcomes. Copyright © 2017 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  8. [The pros and cons of femtosecond laser-assisted cataract surgery].

    PubMed

    Li, Z H; Ye, Z

    2016-02-01

    Femtosecond laser-assisted cataract surgery (FLACS) is known as an innovative new technology. Compared with traditional surgical approach, FLACS is more accurate, more predictable and less energy used. However, in the current stage of development, there still may be intraoperative and postoperative complications, or even serious complications. FLACS has obvious advantages in certain surgical steps, but there are still clear disadvantages, so it still cannot completely replace the traditional phacoemulsification surgery.

  9. Lung Entrapment between the Pectus Bar and Chest Wall after Pectus Surgery: An Incidental Finding during Video-Assisted Thoracoscopic Surgery

    PubMed Central

    Kim, Kyung Soo; Hyun, Kwanyong; Kim, Do Yeon; Choi, Kukbin; Choi, Hahng Joon; Park, Hyung Joo

    2015-01-01

    We report a case of an entrapped lung after the pectus bar repair of a pectus deformity. The entrapped lung was found incidentally during video-assisted thoracoscopic surgery (VATS) for pneumothorax. Based on VATS exploration, multiple bullae seemed to be the cause of the pneumothorax, but the entrapped lung was suspected to have been a cause of the air leakage. PMID:26509135

  10. Desktop-based computer-assisted orthopedic training system for spinal surgery.

    PubMed

    Rambani, Rohit; Ward, James; Viant, Warren

    2014-01-01

    Simulation and surgical training has moved on since its inception during the end of the last century. The trainees are getting more exposed to computers and laboratory training in different subspecialties. More needs to be done in orthopedic simulation in spinal surgery. To develop a training system for pedicle screw fixation and validate its effectiveness in a cohort of junior orthopedic trainees. Fully simulated computer-navigated training system is used to train junior orthopedic trainees perform pedicle screw insertion in the lumbar spine. Real patient computed tomography scans are used to produce the real-time fluoroscopic images of the lumbar spine. The training system was developed to simulate pedicle screw insertion in the lumbar spine. A total of 12 orthopedic senior house officers performed pedicle screw insertion in the lumbar spine before and after the training on training system. The results were assessed based on the scoring system, which included the amount of time taken, accuracy of pedicle screw insertion, and the number of exposures requested to complete the procedure. The result shows a significant improvement in amount of time taken, accuracy of fixation, and the number of exposures after the training on simulator system. This was statistically significant using paired Student t test (p < 0.05). Fully simulated computer-navigated training system is an efficient training tool for young orthopedic trainees. This system can be used to augment training in the operating room, and trainees acquire their skills in the comfort of their study room or in the training room in the hospital. The system has the potential to be used in various other orthopedic procedures for learning of technical skills in a manner aimed at ensuring a smooth escalation in task complexity leading to the better performance of procedures in the operating theater. Copyright © 2014 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  11. Clinical acceptance and accuracy assessment of spinal implants guided with SpineAssist surgical robot: retrospective study.

    PubMed

    Devito, Dennis P; Kaplan, Leon; Dietl, Rupert; Pfeiffer, Michael; Horne, Dale; Silberstein, Boris; Hardenbrook, Mitchell; Kiriyanthan, George; Barzilay, Yair; Bruskin, Alexander; Sackerer, Dieter; Alexandrovsky, Vitali; Stüer, Carsten; Burger, Ralf; Maeurer, Johannes; Donald, Gordon D; Gordon, Donald G; Schoenmayr, Robert; Friedlander, Alon; Knoller, Nachshon; Schmieder, Kirsten; Pechlivanis, Ioannis; Kim, In-Se; Meyer, Bernhard; Shoham, Moshe

    2010-11-15

    Retrospective, multicenter study of robotically-guided spinal implant insertions. Clinical acceptance of the implants was assessed by intraoperative radiograph, and when available, postoperative computed tomography (CT) scans were used to determine placement accuracy. To verify the clinical acceptance and accuracy of robotically-guided spinal implants and compare to those of unguided free-hand procedures. SpineAssist surgical robot has been used to guide implants and guide-wires to predefined locations in the spine. SpineAssist which, to the best of the authors' knowledge, is currently the sole robot providing surgical assistance in positioning tools in the spine, guided over 840 cases in 14 hospitals, between June 2005 and June 2009. Clinical acceptance of 3271 pedicle screws and guide-wires inserted in 635 reported cases was assessed by intraoperative fluoroscopy, where placement accuracy of 646 pedicle screws inserted in 139 patients was measured using postoperative CT scans. Screw placements were found to be clinically acceptable in 98% of the cases when intraoperatively assessed by fluoroscopic images. Measurements derived from postoperative CT scans demonstrated that 98.3% of the screws fell within the safe zone, where 89.3% were completely within the pedicle and 9% breached the pedicle by up to 2 mm. The remaining 1.4% of the screws breached between 2 and 4 mm, while only 2 screws (0.3%) deviated by more than 4 mm from the pedicle wall. Neurologic deficits were observed in 4 cases yet, following revisions, no permanent nerve damage was encountered, in contrast to the 0.6% to 5% of neurologic damage reported in the literature. SpineAssist offers enhanced performance in spinal surgery when compared to free-hand surgeries, by increasing placement accuracy and reducing neurologic risks. In addition, 49% of the cases reported herein used a percutaneous approach, highlighting the contribution of SpineAssist in procedures without anatomic landmarks.

  12. Evaluating the effect of three-dimensional visualization on force application and performance time during robotics-assisted mitral valve repair.

    PubMed

    Currie, Maria E; Trejos, Ana Luisa; Rayman, Reiza; Chu, Michael W A; Patel, Rajni; Peters, Terry; Kiaii, Bob B

    2013-01-01

    The purpose of this study was to determine the effect of three-dimensional (3D) binocular, stereoscopic, and two-dimensional (2D) monocular visualization on robotics-assisted mitral valve annuloplasty versus conventional techniques in an ex vivo animal model. In addition, we sought to determine whether these effects were consistent between novices and experts in robotics-assisted cardiac surgery. A cardiac surgery test-bed was constructed to measure forces applied during mitral valve annuloplasty. Sutures were passed through the porcine mitral valve annulus by the participants with different levels of experience in robotics-assisted surgery and tied in place using both robotics-assisted and conventional surgery techniques. The mean time for both the experts and the novices using 3D visualization was significantly less than that required using 2D vision (P < 0.001). However, there was no significant difference in the maximum force applied by the novices to the mitral valve during suturing (P = 0.7) and suture tying (P = 0.6) using either 2D or 3D visualization. The mean time required and forces applied by both the experts and the novices were significantly less using the conventional surgical technique than when using the robotic system with either 2D or 3D vision (P < 0.001). Despite high-quality binocular images, both the experts and the novices applied significantly more force to the cardiac tissue during 3D robotics-assisted mitral valve annuloplasty than during conventional open mitral valve annuloplasty. This finding suggests that 3D visualization does not fully compensate for the absence of haptic feedback in robotics-assisted cardiac surgery.

  13. Clinical relevance of model based computer-assisted diagnosis and therapy

    NASA Astrophysics Data System (ADS)

    Schenk, Andrea; Zidowitz, Stephan; Bourquain, Holger; Hindennach, Milo; Hansen, Christian; Hahn, Horst K.; Peitgen, Heinz-Otto

    2008-03-01

    The ability to acquire and store radiological images digitally has made this data available to mathematical and scientific methods. With the step from subjective interpretation to reproducible measurements and knowledge, it is also possible to develop and apply models that give additional information which is not directly visible in the data. In this context, it is important to know the characteristics and limitations of each model. Four characteristics assure the clinical relevance of models for computer-assisted diagnosis and therapy: ability of patient individual adaptation, treatment of errors and uncertainty, dynamic behavior, and in-depth evaluation. We demonstrate the development and clinical application of a model in the context of liver surgery. Here, a model for intrahepatic vascular structures is combined with individual, but in the degree of vascular details limited anatomical information from radiological images. As a result, the model allows for a dedicated risk analysis and preoperative planning of oncologic resections as well as for living donor liver transplantations. The clinical relevance of the method was approved in several evaluation studies of our medical partners and more than 2900 complex surgical cases have been analyzed since 2002.

  14. Learning curve for robotic-assisted surgery for rectal cancer: use of the cumulative sum method.

    PubMed

    Yamaguchi, Tomohiro; Kinugasa, Yusuke; Shiomi, Akio; Sato, Sumito; Yamakawa, Yushi; Kagawa, Hiroyasu; Tomioka, Hiroyuki; Mori, Keita

    2015-07-01

    Few data are available to assess the learning curve for robotic-assisted surgery for rectal cancer. The aim of the present study was to evaluate the learning curve for robotic-assisted surgery for rectal cancer by a surgeon at a single institute. From December 2011 to August 2013, a total of 80 consecutive patients who underwent robotic-assisted surgery for rectal cancer performed by the same surgeon were included in this study. The learning curve was analyzed using the cumulative sum method. This method was used for all 80 cases, taking into account operative time. Operative procedures included anterior resections in 6 patients, low anterior resections in 46 patients, intersphincteric resections in 22 patients, and abdominoperineal resections in 6 patients. Lateral lymph node dissection was performed in 28 patients. Median operative time was 280 min (range 135-683 min), and median blood loss was 17 mL (range 0-690 mL). No postoperative complications of Clavien-Dindo classification Grade III or IV were encountered. We arranged operative times and calculated cumulative sum values, allowing differentiation of three phases: phase I, Cases 1-25; phase II, Cases 26-50; and phase III, Cases 51-80. Our data suggested three phases of the learning curve in robotic-assisted surgery for rectal cancer. The first 25 cases formed the learning phase.

  15. Laparoscopic surgery for colon cancer with intestinal malrotation in adults: Two case reports and review of literatures in Japan.

    PubMed

    Nakatani, Kazuyoshi; Tokuhara, Katsuji; Sakaguchi, Tatsuma; Yoshioka, Kazuhiko; Kon, Masanori

    2017-01-01

    Intestinal malrotation is a congenital anomaly, and its occurrence in adults is rare. Colon cancer with intestinal malrotation is far more rare. We herein report two cases of colon cancer with intestinal malrotation treated with laparoscopic surgery and reviewed the literatures in Japan. Case 1 involved a 78-year-old man. Abdominal enhanced computed tomography (CT) showed that the tumor was located in the sigmoid colon. Intraoperatively, the cecum and ascending colon were located along the midline and the small intestine occupied the right side of the abdomen. The tumor was located in the cecum, and the patient was diagnosed with cecal cancer with intestinal malrotation. We performed laparoscopy-assisted ileocecal resection. Case 2 involved a 81-year-old man. Colonoscopy revealed a laterally spreading tumor in the cecum. Intraoperatively, the position of the small intestine and the ascending colon was similar to case 1, and Ladd's band was found in front of the duodenum. Thus, we diagnosed the patient with a laterally spreading cecal tumor with intestinal malrotation and performed laparoscopy-assisted ileocecal resection. A review of the literature revealed 49 cases of colon cancer with intestinal malrotation and laparoscopic surgery performed at 30.6%. If laparoscopic mesenteric excision for colon cancer with intestinal malrotation is unsafe because of the abnormalities of the artery, mesenteric excision should be performed outside the body. If the intestinal malrotation is diagnosed preoperatively, 3D-CT angiography should be used to reveal the vascular anatomic anomalies for safe performance of laparoscopic surgery. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  16. History and current status of mini-invasive thoracic surgery

    PubMed Central

    He, Jianxing

    2011-01-01

    Mini-invasive thoracic technique mainly refers to a technique involving the significant reduction of the chest wall access-related trauma. Notably, thoracoscope is the chief representative. The development of thoracoscope technique is characterized by: developing from direct peep to artificial lighting, then combination with image and video technique in equipments; technically developing from diagnostic to therapeutic approaches; developing from simpleness to complexity in application scope; and usually developing together with other techniques. At present, the widely used mini-invasive thoracic surgery refers to the mini-open thoracic surgery performed mainly by using some instruments to control target tissues and organs based on the vision associated with multi-limb coordination, which may be hand-assisted if necessary. The mini-invasive thoracic surgery consists of three approaches including video-assisted thoracic surgery (VATS), video-assisted Hybrid and hand-assisted VATS. So far the mini-invasive thoracic technique has achieved great advances due to the development in instruments of mini-invasive thoracic surgery which has the following features: instruments of mini-invasive thoracic surgery appear to be safe and practical, and have successive improvement and diversification in function; the specific instruments of open surgeries has been successively developed into dedicated instruments of endoscopic surgery; the application of endoscopic mechanical suture device generates faster fragmentation and reconstruction of organ tissues; the specific delicated instruments of endoscopic surgery have rapid development and application; and the simple instruments structurally similar to the conventional instruments are designed according to the mini-incison. In addition, the mini-invasive thoracic technique is widely used in five aspects including diseases of pleura membrane and chest wall, lung diseases, esophageal diseases, mediastinal diseases and heart diseases. However, there remain many problems in specifications and trainings, economic cost, conservation and innovation. Therefore, particular attention should be paid to these problems. Nevertheless, the promotion of thoracic surgery appears promising in the future. PMID:22263074

  17. Virtual occlusal definition for orthognathic surgery.

    PubMed

    Liu, X J; Li, Q Q; Zhang, Z; Li, T T; Xie, Z; Zhang, Y

    2016-03-01

    Computer-assisted surgical simulation is being used increasingly in orthognathic surgery. However, occlusal definition is still undertaken using model surgery with subsequent digitization via surface scanning or cone beam computed tomography. A software tool has been developed and a workflow set up in order to achieve a virtual occlusal definition. The results of a validation study carried out on 60 models of normal occlusion are presented. Inter- and intra-user correlation tests were used to investigate the reproducibility of the manual setting point procedure. The errors between the virtually set positions (test) and the digitized manually set positions (gold standard) were compared. The consistency in virtual set positions performed by three individual users was investigated by one way analysis of variance test. Inter- and intra-observer correlation coefficients for manual setting points were all greater than 0.95. Overall, the median error between the test and the gold standard positions was 1.06mm. Errors did not differ among teeth (F=0.371, P>0.05). The errors were not significantly different from 1mm (P>0.05). There were no significant differences in the errors made by the three independent users (P>0.05). In conclusion, this workflow for virtual occlusal definition was found to be reliable and accurate. Copyright © 2015 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  18. Clinical assessment and management of general surgery patients via synchronous telehealth.

    PubMed

    Cain, Steven M; Moore, Robert; Sturm, Lauren; Mason, Travis; Fuhrman, Caitlin; Smith, Robin; Bojicic, Irfan; Carter, Brandon

    2017-02-01

    Objective This paper describes how a clinical team at Landstuhl Regional Medical Center (LRMC) successfully integrated synchronous telehealth (TH) into their routine clinical practice. Methods and materials Synchronous TH encounters were performed using Polycom® software on surgeons' computers with high-definition (HD) cameras on monitors at distant sites and PolyCom HDX9000® Telehealth Practitioner Carts at originating sites. Patients provided consented and were presented to general surgeons by nurses and medical technicians at Army health clinics throughout the European Theater. Results In calendar year (CY) 2014, five general surgeons and two surgical physician assistants (PAs) at Landstuhl Regional Medical Center along with registered nurses (RNs) at six originating clinic sites throughout Europe completed 130 synchronous TH encounters for 101 general surgery patients resulting in 73 completed and 16 recommended surgeries. Eighty-eight percent of patients had a completed or recommended surgery. No surgeries or procedures planned after initial TH evaluation were cancelled. Originating site clinics ranged in distance from 68 miles to 517 miles. Acceptance by providers, patients and clinic staff was high. Conclusion Synchronous TH was effective and safe in evaluating common general surgical conditions. We excluded sensitive and complex conditions requiring a nuanced physical examination. The TH efforts of the general surgery staff have resulted in high-quality, seamless and predictable TH activities that continue to expand into other surgical and medical specialties beyond general surgery. Seven surgeons and two PAs use synchronous TH regularly serving patients over a broad geographic area.

  19. Virtual Surgical Planning: The Pearls and Pitfalls

    PubMed Central

    Efanov, Johnny I.; Roy, Andrée-Anne; Huang, Ke N.

    2018-01-01

    Objective: Over the past few years, virtual surgical planning (VSP) has evolved into a useful tool for the craniofacial surgeon. Virtual planning and computer-aided design and manufacturing (CAD/CAM) may assist in orthognathic, cranio-orbital, traumatic, and microsurgery of the craniofacial skeleton. Despite its increasing popularity, little emphasis has been placed on the learning curve. Methods: A retrospective analysis of consecutive virtual surgeries was done from July 2012 to October 2016 at the University of Montreal Teaching Hospitals. Orthognathic surgeries and free vascularized bone flap surgeries were included in the analysis. Results: Fifty-four virtual surgeries were done in the time period analyzed. Forty-six orthognathic surgeries and 8 free bone transfers were done. An analysis of errors was done. Eighty-five percentage of the orthognathic virtual plans were adhered to completely, 4% of the plans were abandoned, and 11% were partially adhered to. Seventy-five percentage of the virtual surgeries for free tissue transfers were adhered to, whereas 25% were partially adhered to. The reasons for abandoning the plans were (1) poor communication between surgeon and engineer, (2) poor appreciation for condyle placement on preoperative scans, (3) soft-tissue impedance to bony movement, (4) rapid tumor progression, (5) poor preoperative assessment of anatomy. Conclusion: Virtual surgical planning is a useful tool for craniofacial surgery but has inherent issues that the surgeon must be aware of. With time and experience, these surgical plans can be used as powerful adjuvants to good clinical judgement. PMID:29464146

  20. A survey of the satisfaction of patients who have undergone implant surgery with and without employing a computer-guided implant surgical template

    PubMed Central

    Youk, Shin-Young; Lee, Jee-Ho; Heo, Seong-Joo; Roh, Hyun-Ki; Park, Eun-Jin; Shin, Im Hee

    2014-01-01

    PURPOSE This study aims to investigate the degree of subjective pain and the satisfaction of patients who have undergone an implant treatment using a computer-guided template. MATERIALS AND METHODS A survey was conducted for 135 patients who have undergone implant surgery with and without the use of the computer-guided template during the period of 2012 and 2013 in university hospitals, dental hospitals and dental clinics that practiced implant surgery using the computer-guided template. Likert scale and VAS score were used in the survey questions, and the independent t-test and One-Way ANOVA were performed (α=.05). RESULTS The route that the subjects were introduced to the computer-guided implant surgery using a surgical template was mostly advices by dentists, and the most common reason for which they chose to undergo such surgery was that it was accurate and safe. Most of them gave an answer that they were willing to recommend it to others. The patients who have undergone the computer-guided implant surgery felt less pain during the operation and showed higher satisfaction than those who have undergone conventional implant surgery. Among the patients who have undergone computer-guided implant surgery, those who also had prior experience of surgery without a computer-guided template expressed higher satisfaction with the former (P<.05). CONCLUSION In this study, it could be seen that the patients who have undergone computer-guided implant surgery employing a surgical template felt less pain and had higher satisfaction than those with the conventional one, and the dentist's description could provide the confidence about the safety of surgery. PMID:25352962

  1. Negative pressure wound therapy‐assisted dermatotraction for the closure of large open wounds in a patient with non‐clostridial gas gangrene

    PubMed Central

    Noborio, Mitsuhiro; Nishimura, Tetsuro; Ieki, Yohei; Shimahara, Yumiko; Sogabe, Taku; Ehara, Naoki; Saoyama, Yuki; Sadamitsu, Daikai

    2015-01-01

    Case A 53‐year‐old woman developed septic shock associated with non‐clostridial gas gangrene. She presented to the emergency department with two large open wounds on both thighs and in her sacral region. Non‐enhanced computed tomography showed air density in contact with the right iliopsoas, which extended to the posterior compartment of the thigh. We made repeated efforts at surgical debridement of the wound with resection of necrotic tissues. Outcome Using negative pressure wound therapy‐assisted dermatotraction, the pus pockets and the wound dehiscence decreased in size. Using this method we were successful in achieving delayed closure without skin grafts. Conclusion Negative pressure wound therapy can be an effective treatment for large and infected open contoured wounds. Negative pressure wound therapy‐assisted dermatotraction might be beneficial for poorly healing, large, open wounds in patients in poor condition and with insufficient reserve to tolerate reconstructive surgery. PMID:29123764

  2. Evaluation of short- and long-term complications after endoscopically assisted gastropexy in dogs.

    PubMed

    Dujowich, Mauricio; Keller, Mattew E; Reimer, S Brent

    2010-01-15

    To determine short- and long-term complications in clinically normal dogs after endoscopically assisted gastropexy. Prospective case series. 24 dogs. Endoscopically assisted gastropexy was performed on each dog. Dogs were evaluated laparoscopically at 1 or 6 months after surgery to assess integrity of the gastropexy. Long-term outcome was determined via telephone conversations conducted with owners > or = 1 year after surgery. Mean +/- SD gastropexy length was 4.5 +/- 0.9 cm, and mean duration of surgery was 22 +/- 5 minutes. One dog had a partially rotated stomach at the time of insufflation, which was corrected by untwisting the stomach with Babcock forceps. Two dogs vomited within 4 weeks after surgery, but the vomiting resolved in both dogs. Four dogs had diarrhea within 4 weeks after surgery, which resolved without medical intervention. In all dogs, the gastropexy site was firmly adhered to the abdominal wall at the level of the pyloric antrum. Long-term follow-up information was available for 23 dogs, none of which had any episodes of gastric dilatation-volvulus a mean of 1.4 years after gastropexy. Endoscopically assisted gastropexy can be a simple, fast, safe, and reliable method for performing prophylactic gastropexy in dogs. At 1 and 6 months after gastropexy, adequate placement and adhesion of the gastropexy site to the body wall was confirmed. Such a procedure could maximize the benefits of minimally invasive surgery, such as decreases in morbidity rate and anesthetic time. This technique appeared to be suitable as an alternative to laparoscopic-assisted gastropexy.

  3. Laparoscopic and robot-assisted laparoscopic digestive surgery: Present and future directions

    PubMed Central

    Rodríguez-Sanjuán, Juan C; Gómez-Ruiz, Marcos; Trugeda-Carrera, Soledad; Manuel-Palazuelos, Carlos; López-Useros, Antonio; Gómez-Fleitas, Manuel

    2016-01-01

    Laparoscopic surgery is applied today worldwide to most digestive procedures. In some of them, such as cholecystectomy, Nissen’s fundoplication or obesity surgery, laparoscopy has become the standard in practice. In others, such as colon or gastric resection, the laparoscopic approach is frequently used and its usefulness is unquestionable. More complex procedures, such as esophageal, liver or pancreatic resections are, however, more infrequently performed, due to the high grade of skill necessary. As a result, there is less clinical evidence to support its implementation. In the recent years, robot-assisted laparoscopic surgery has been increasingly applied, again with little evidence for comparison with the conventional laparoscopic approach. This review will focus on the complex digestive procedures as well as those whose use in standard practice could be more controversial. Also novel robot-assisted procedures will be updated. PMID:26877605

  4. Evaluation and Impact of Workflow Interruptions During Robot-assisted Surgery.

    PubMed

    Allers, Jenna C; Hussein, Ahmed A; Ahmad, Nabeeha; Cavuoto, Lora; Wing, Joseph F; Hayes, Robin M; Hinata, Nobuyuki; Bisantz, Ann M; Guru, Khurshid A

    2016-06-01

    To analyze and categorize causes for interruptions during robot-assisted surgery. We analyzed 10 robot-assisted prostatectomies that were performed by 3 surgeons from October 2014 to June 2015. Interruptions to surgery were defined in terms of duration, stage of surgery, personnel involved, reasons, and impact of the interruption on the surgical workflow. The main reasons for interruptions included the following: console surgeons switching (29%); preparation of the surgical equipment, such as cleaning or changing the camera (29%) or an instrument (27%); or when a suture, stapler, or clip was needed (12%). The most common interruption duration was 10-29 seconds (47.6%), and the least common interruption duration was greater than 90 seconds (3.6%). Additionally, about 14% of the interruptions were considered avoidable, whereas the remaining 86% of interruptions were necessary for surgery. By identifying and analyzing interruptions, we can develop evidence-based strategies to improve operating room efficiency, lower costs, and advance patient safety. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. 3D point cloud analysis of structured light registration in computer-assisted navigation in spinal surgeries

    NASA Astrophysics Data System (ADS)

    Gupta, Shaurya; Guha, Daipayan; Jakubovic, Raphael; Yang, Victor X. D.

    2017-02-01

    Computer-assisted navigation is used by surgeons in spine procedures to guide pedicle screws to improve placement accuracy and in some cases, to better visualize patient's underlying anatomy. Intraoperative registration is performed to establish a correlation between patient's anatomy and the pre/intra-operative image. Current algorithms rely on seeding points obtained directly from the exposed spinal surface to achieve clinically acceptable registration accuracy. Registration of these three dimensional surface point-clouds are prone to various systematic errors. The goal of this study was to evaluate the robustness of surgical navigation systems by looking at the relationship between the optical density of an acquired 3D point-cloud and the corresponding surgical navigation error. A retrospective review of a total of 48 registrations performed using an experimental structured light navigation system developed within our lab was conducted. For each registration, the number of points in the acquired point cloud was evaluated relative to whether the registration was acceptable, the corresponding system reported error and target registration error. It was demonstrated that the number of points in the point cloud neither correlates with the acceptance/rejection of a registration or the system reported error. However, a negative correlation was observed between the number of the points in the point-cloud and the corresponding sagittal angular error. Thus, system reported total registration points and accuracy are insufficient to gauge the accuracy of a navigation system and the operating surgeon must verify and validate registration based on anatomical landmarks prior to commencing surgery.

  6. Editorial Commentary: The Great Endoscopically Assisted Bunion Surgery That Will Never Become Popular-I Will Not Try This at Home.

    PubMed

    Thordarson, David

    2018-06-01

    Bunion surgery almost invariably involves osteotomies and open incisions. Recently, some surgeons have been performing minimally invasive osteotomies with less morbidity, more rapid healing, and good results. These surgeries are heavily technique dependent, and other surgeons cannot always reproduce these results. Endoscopically assisted bunion surgery yielded excellent results at 10 years in this study but will likely never be used commonly because of the extremely demanding surgical technique and requisite learning curve. Copyright © 2018 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  7. Controversy of hand-assisted laparoscopic colorectal surgery

    PubMed Central

    Meshikhes, Abdul-Wahed Nasir

    2010-01-01

    Laparoscopically assisted colorectal procedures are time-consuming and technically demanding and hence have a long steep learning curve. In the technical demand, surgeons need to handle a long mobile organ, the colon, and have to operate on multiple abdominal quadrants, most of the time with the need to secure multiple mesenteric vessels. Therefore, a new surgical innovation called hand-assisted laparoscopic surgery (HALS) was introduced in the mid 1990s as a useful alternative to totally laparoscopic procedures. This hybrid operation allows the surgeon to introduce the non-dominant hand into the abdominal cavity through a special hand port while maintaining the pneumoperitoneum. A hand in the abdomen can restore the tactile sensation which is usually lacking in laparoscopic procedures. It also improves the eye-to-hand coordination, allows the hand to be used for blunt dissection or retraction and also permits rapid control of unexpected bleeding. All of those factors can contribute tremendously to reducing the operative time. Moreover, this procedure is also considered as a hybrid procedure that combines the advantages of both minimally invasive and conventional open surgery. Nevertheless, the exact role of HALS in colorectal surgery has not been well defined during the advanced totally laparoscopic procedures. This article reviews the current status of hand-assisted laparoscopic colorectal surgery as a minimally invasive procedure in the era of laparoscopic surgery. PMID:21128315

  8. Robot-Assisted Transoral Odontoidectomy : Experiment in New Minimally Invasive Technology, a Cadaveric Study

    PubMed Central

    Yang, Moon Sul; Yoon, Tae Ho; Yoon, Do Heum; Kim, Keung Nyun; Pennant, William

    2011-01-01

    Objective In the field of spinal surgery, a few laboratory results or clinical cases about robotic spinal surgery have been reported. In vivo trials and development of related surgical instruments for spinal surgery are required before its clinical application. We investigated the use of the da Vinci® Surgical System in spinal surgery at the craniovertebral junction in a human cadaver to demonstrate the efficacy and pitfalls of robotic surgery. Methods Dissection of pharyngeal wall to the exposure of C1 and odontoid process was performed with full robotic procedure. Although assistance of another surgeon was necessary for drilling and removal of odontoid process due to the lack of appropriate end-effectors, successful robotic procedures for dural sutures and exposing spinal cord proved its safety and dexterity. Results Robot-assisted odontoidectomy was successfully performed in a human cadaver using the da Vinci® Surgical System with few robotic arm collisions and minimal soft tissue damages. Da Vinci® Surgical System manifested more dexterous movement than human hands in the deep and narrow oral cavity. Furthermore, sutures with robotic procedure in the oral cavity demonstrated the advantage over conventional procedure. Conclusion Presenting cadaveric study proved the probability of robot-assisted transoral approach. However, the development of robotic instruments specific to spinal surgery must first precede its clinical application. PMID:21607188

  9. Navigating the pathway to robotic competency in general thoracic surgery.

    PubMed

    Seder, Christopher W; Cassivi, Stephen D; Wigle, Dennis A

    2013-01-01

    Although robotic technology has addressed many of the limitations of traditional videoscopic surgery, robotic surgery has not gained widespread acceptance in the general thoracic community. We report our initial robotic surgery experience and propose a structured, competency-based pathway for the development of robotic skills. Between December 2008 and February 2012, a total of 79 robot-assisted pulmonary, mediastinal, benign esophageal, or diaphragmatic procedures were performed. Data on patient characteristics and perioperative outcomes were retrospectively collected and analyzed. During the study period, one surgeon and three residents participated in a triphasic, competency-based pathway designed to teach robotic skills. The pathway consisted of individual preclinical learning followed by mentored preclinical exercises and progressive clinical responsibility. The robot-assisted procedures performed included lung resection (n = 38), mediastinal mass resection (n = 19), hiatal or paraesophageal hernia repair (n = 12), and Heller myotomy (n = 7), among others (n = 3). There were no perioperative mortalities, with a 20% complication rate and a 3% readmission rate. Conversion to a thoracoscopic or open approach was required in eight pulmonary resections to facilitate dissection (six) or to control hemorrhage (two). Fewer major perioperative complications were observed in the later half of the experience. All residents who participated in the thoracic surgery robotic pathway perform robot-assisted procedures as part of their clinical practice. Robot-assisted thoracic surgery can be safely learned when skill acquisition is guided by a structured, competency-based pathway.

  10. Supervised autonomous robotic soft tissue surgery.

    PubMed

    Shademan, Azad; Decker, Ryan S; Opfermann, Justin D; Leonard, Simon; Krieger, Axel; Kim, Peter C W

    2016-05-04

    The current paradigm of robot-assisted surgeries (RASs) depends entirely on an individual surgeon's manual capability. Autonomous robotic surgery-removing the surgeon's hands-promises enhanced efficacy, safety, and improved access to optimized surgical techniques. Surgeries involving soft tissue have not been performed autonomously because of technological limitations, including lack of vision systems that can distinguish and track the target tissues in dynamic surgical environments and lack of intelligent algorithms that can execute complex surgical tasks. We demonstrate in vivo supervised autonomous soft tissue surgery in an open surgical setting, enabled by a plenoptic three-dimensional and near-infrared fluorescent (NIRF) imaging system and an autonomous suturing algorithm. Inspired by the best human surgical practices, a computer program generates a plan to complete complex surgical tasks on deformable soft tissue, such as suturing and intestinal anastomosis. We compared metrics of anastomosis-including the consistency of suturing informed by the average suture spacing, the pressure at which the anastomosis leaked, the number of mistakes that required removing the needle from the tissue, completion time, and lumen reduction in intestinal anastomoses-between our supervised autonomous system, manual laparoscopic surgery, and clinically used RAS approaches. Despite dynamic scene changes and tissue movement during surgery, we demonstrate that the outcome of supervised autonomous procedures is superior to surgery performed by expert surgeons and RAS techniques in ex vivo porcine tissues and in living pigs. These results demonstrate the potential for autonomous robots to improve the efficacy, consistency, functional outcome, and accessibility of surgical techniques. Copyright © 2016, American Association for the Advancement of Science.

  11. Maximizing Use of Robot-Arm No. 3 in Da Vinci–Assisted Thoracic Surgery

    PubMed Central

    Kajiwara, Naohiro; Maeda, Junichi; Yoshida, Koichi; Kato, Yasufumi; Hagiwara, Masaru; Kakihana, Masatoshi; Ohira, Tatsuo; Kawate, Norihiko; Ikeda, Norihiko

    2015-01-01

    We have previously reported on the importance of appropriate robot-arm settings and replacement of instrument ports in robot-assisted thoracic surgery, because the thoracic cavity requires a large space to access all lesions in various areas of the thoracic cavity from the apex to the diaphragm and mediastinum and the chest wall.1–3 Moreover, it can be difficult to manipulate the da Vinci Surgical System using only arms No. 1 and No. 2 depending on the tumor location. However, arm No. 3 is usually positioned on the same side as arm No. 2, and sometimes it is only used as an assisting-arm to avoid conflict with other arms (Fig. 1). In this report, we show how robot-arm No. 3 can be used with maximum effectiveness in da Vinci-assisted thoracic surgery. PMID:26011219

  12. TECHNIQUES IN ASEPTIC RODENT SURGERY

    PubMed Central

    Hoogstraten-Miller, Shelley L.; Brown, Patricia A.

    2008-01-01

    Performing aseptic survival surgery in rodents can be challenging. This unit describes some basic principles to assist clinicians, researchers, and technicians in becoming proficient in performing aseptic rodent surgery. PMID:18729061

  13. Best practices for minimally invasive procedures.

    PubMed

    Ulmer, Brenda C

    2010-05-01

    Techniques and instrumentation for minimally invasive surgical procedures originated in gynecologic surgery, but the benefits of surgery with small incisions or no incisions at all have prompted the expansion of these techniques into numerous specialties. Technologies such as robotic assistance, single-incision laparoscopic surgery, natural orifice transluminal endoscopic surgery, and video-assisted thoracoscopic surgery have led to the continued expansion of minimally invasive surgery into new specialties. With this expansion, perioperative nurses and other members of the surgical team are required to continue to learn about new technology and instrumentation, as well as the techniques and challenges involved in using new technology, to help ensure the safety of their patients. This article explores the development of minimally invasive procedures and offers suggestions for increasing patient safety. Copyright 2010 AORN, Inc. Published by Elsevier Inc. All rights reserved.

  14. LOCAL ORTHOGONAL CUTTING METHOD FOR COMPUTING MEDIAL CURVES AND ITS BIOMEDICAL APPLICATIONS

    PubMed Central

    Einstein, Daniel R.; Dyedov, Vladimir

    2010-01-01

    Medial curves have a wide range of applications in geometric modeling and analysis (such as shape matching) and biomedical engineering (such as morphometry and computer assisted surgery). The computation of medial curves poses significant challenges, both in terms of theoretical analysis and practical efficiency and reliability. In this paper, we propose a definition and analysis of medial curves and also describe an efficient and robust method called local orthogonal cutting (LOC) for computing medial curves. Our approach is based on three key concepts: a local orthogonal decomposition of objects into substructures, a differential geometry concept called the interior center of curvature (ICC), and integrated stability and consistency tests. These concepts lend themselves to robust numerical techniques and result in an algorithm that is efficient and noise resistant. We illustrate the effectiveness and robustness of our approach with some highly complex, large-scale, noisy biomedical geometries derived from medical images, including lung airways and blood vessels. We also present comparisons of our method with some existing methods. PMID:20628546

  15. Robot-assisted Salvage Lymph Node Dissection for Clinically Recurrent Prostate Cancer.

    PubMed

    Montorsi, Francesco; Gandaglia, Giorgio; Fossati, Nicola; Suardi, Nazareno; Pultrone, Cristian; De Groote, Ruben; Dovey, Zach; Umari, Paolo; Gallina, Andrea; Briganti, Alberto; Mottrie, Alexandre

    2017-09-01

    Salvage lymph node dissection has been described as a feasible treatment for the management of prostate cancer patients with nodal recurrence after primary treatment. To report perioperative, pathologic, and oncologic outcomes of robot-assisted salvage nodal dissection (RASND) in patients with nodal recurrence after radical prostatectomy (RP). We retrospectively evaluated 16 patients affected by nodal recurrence following RP documented by positive positron emission tomography/computed tomography scan. Surgery was performed using DaVinci Si and Xi systems. A pelvic nodal dissection that included lymphatic stations overlying the external, internal, and common iliac vessels, the obturator fossa, and the presacral nodes was performed. In 13 (81.3%) patients a retroperitoneal lymph node dissection that included all nodal tissue located between the aortic bifurcation and the renal vessels was performed. Perioperative outcomes consisted of operative time, blood loss, length of hospital stay, and complications occurred within 30 d after surgery. Biochemical response (BR) was defined as a prostate-specific antigen level <0.2 ng/ml at 40 d after RASND. Median operative time, blood loss, and length of hospital stay were 210min, 250ml, and 3.5 d. The median number of nodes removed was 16.5. Positive lymph nodes were detected in 11 (68.8%) patients. Overall, four (25.0%) and five (31.2%) patients experienced intraoperative and postoperative complications, respectively. Overall, one (6.3%) and four (25.0%) patients had Clavien I and II complications within 30 d after RASND, respectively. Overall, five (33.3%) patients experienced BR after surgery. Our study is limited by the small cohort of patients evaluated and by the follow-up duration. RASND represents a feasible procedure in patients with nodal recurrence after RP and provides acceptable short-term oncologic outcomes, where one out of three patients experience BR immediately after surgery. Long-term data are needed to confirm the effectiveness of this approach. We report our initial experience with robot-assisted salvage nodal dissection for the management of patients with lymph node recurrence after radical prostatectomy. This technique represents a feasible and effective approach, where no high-grade complications were recorded and one out of three patients experienced biochemical response at 40 d after surgery. Copyright © 2016 European Association of Urology. Published by Elsevier B.V. All rights reserved.

  16. Video-assisted thoracoscopic surgery (VATS) right upper lobectomy for non-small-cell lung cancer with an azygos lobe

    PubMed Central

    Samancilar, Ozgur; Kaya, Seyda Ors; Sevinc, Serpil; Akcay, Onur; Ceylan, Kenan Can

    2016-01-01

    Although it is not a pathologically significant entity, cases of azygos lobe (AL) are interesting due to the difficulty of performing video-assisted thoracoscopic surgery (VATS) procedures in the affected patients and the presence of a congenital malformation. Currently, videothoracoscopic surgery has advanced to such a level that most thoracic procedures can be performed with video assistance. However, some technical difficulties may arise in cases with anatomical anomalies such as AL. This report presents the case of a patient with an azygos lobe who underwent videothoracoscopic lung resection due to the presence of non-small-cell lung carcinoma in the upper lobe of the right lung. PMID:28096840

  17. Minimally invasive colorectal surgery: status and technical specifications.

    PubMed

    Keller, D S; Ibarra, S; Haas, E M

    2015-10-01

    Laparoscopy was the most significant technologic advance in colorectal surgery in the last quarter century. The safety, feasibility and oncologic equivalence have been proven, and undisputed clinical benefits have also been demonstrated over open approaches. Despite proven benefits, laparoscopic has not dominated the market, especially for colon and rectal cancer cases. Adaptations in laparoscopic technique were developed to increase use of minimally invasive surgery. Concurrently, there has been a paradigm shift toward less invasive technologies to further optimize patient outcomes. From these needs, hand assisted laparoscopic surgery (HALS), single incision laparoscopic surgery (SILS), and robotic assisted laparoscopic surgery (RALS) were applied to colorectal surgery. Each platform has unique costs and benefits, and similar outcomes when likened to each other in comparative studies. However, conventional laparoscopy, HALS, SILS, and RALS actually serve a complementary role as tools to increase the use of minimally invasive colorectal surgery. The goal of this paper is to review the history, current status, technical specifications, and evolution of the major minimally invasive platforms for colorectal surgery.

  18. Software-assisted live visualization system for subjacent blood vessels in endonasal endoscopic approaches

    NASA Astrophysics Data System (ADS)

    Lempe, B.; Taudt, Ch.; Maschke, R.; Gruening, J.; Ernstberger, M.; Basan, F.; Baselt, T.; Grunert, R.; Hartmann, P.

    2013-02-01

    Minimal invasive surgery methods have received growing attention in recent years. In vital important areas, it is crucial for the surgeon to have a precise knowledge of the tissue structure. Especially the visualization of arteries is desirable, as the destruction of the same can be lethal to the patient. In order to meet this requirement, the study presents a novel assistance system for endoscopic surgery. While state-of-the art systems rely on pre-operational data like computer-tomographic maps and require the use of radiation, the goal of the presented approach is to provide the clarification of subjacent blood vessels on live images of the endoscope camera system. Based on the transmission and reflection spectra of various human tissues, a prototype system with a NIR illumination unit working at 808 nm was established. Several image filtering, processing and enhancement techniques have been investigated and evaluated on the raw pictures in order to obtain high quality results. The most important were increasing contrast and thresholding by difference of Gaussian method. Based on that, it is possible to rectify a fragmented artery pattern and extract geometrical information about the structure in terms of position and orientation. By superposing the original image and the extracted segment, the surgeon is assisted with valuable live pictures of the region of interest. The whole system has been tested on a laboratory scale. An outlook on the integration of such a system in a clinical environment and obvious benefits are discussed.

  19. Can Navigation-assisted Surgery Help Achieve Negative Margins in Resection of Pelvic and Sacral Tumors?

    PubMed

    Abraham, John A; Kenneally, Barry; Amer, Kamil; Geller, David S

    2018-03-01

    Navigation-assisted resection has been proposed as a useful adjunct to resection of malignant tumors in difficult anatomic sites such as the pelvis and sacrum where it is difficult to achieve tumor-free margins. Most of these studies are case reports or small case series, but these reports have been extremely promising. Very few reports, however, have documented benefits of navigation-assisted resection in series of pelvic and sacral primary tumors. Because this technology may add time and expense to the surgical procedure, it is important to determine whether navigation provides any such benefits or simply adds cost and time to an already complex procedure. (1) What proportion of pelvic and sacral bone sarcoma resections utilizing a computer-assisted resection technique achieves negative margins? (2) What are the oncologic outcomes associated with computer-assisted resection of pelvic and sacral bone sarcomas? (3) What complications are associated with navigation-assisted resection? Between 2009 and 2015 we performed 24 navigation-assisted resections of primary tumors of the pelvis or sacrum. Of those, four were lost to followup after the 2-year postoperative visit. In one patient, however, there was a failure of navigation as a result of inadequate imaging, so nonnavigated resection was performed; the remaining 23 were accounted for and were studied here at a mean of 27 months after surgery (range, 12-52 months). During this period, we performed navigation-assisted resections in all patients presenting with a pelvis or sacral tumor; there was no selection process. No patients were treated for primary tumors in these locations without navigation during this time with the exception of the single patient in whom the navigation system failed. We retrospectively evaluated the records of these 23 patients and evaluated the margin status of these resections. We calculated the proportion of patients with local recurrence, development of metastases, and overall survival at an average 27-month followup (range, 12-52 months). We queried a longitudinally maintained surgical database for any complications and noted which, if any, could have been directly related to the use of the navigation-assisted technique. In our series, 21 of 23 patients had a negative margin resection. In all patients the bone margin was negative, but two with sacral resections had positive soft tissue margins. Six of 23 patients experienced local recurrence within the study period. Three patients died during the study period. Seventeen patients demonstrated no evidence of disease at last recorded followup. We noted three intraoperative complications: one dural tear, one iliac vein laceration, and one bladder injury. Eight patients out of 23 had wound complications resulting in operative débridement. Two patients in the series developed transient postoperative femoral nerve palsy, which we believe were caused by stretch of the femoral nerve secondary to the placement of the reference array in the pubic ramus. Navigation-assisted resection of pelvic and sacral tumors resulted in a high likelihood of negative margin resection in this series, and we observed relatively few complications related specifically to the navigation. We have no comparison group without navigation, and future studies should indeed compare navigated with nonnavigated resection approaches in these anatomic locations. We did identify a potential navigation-related complication of femoral nerve palsy in this series and suggest careful placement and observation of the reference array during the operative procedure to lessen the likelihood of this previously unreported complication. We suggest it is worthwhile to consider the use of navigation-assisted surgery in resection of tumors of the pelvis and sacrum, but further study will be needed to determine its precise impact, if any, on local recurrence and other oncologic outcomes. Level IV, therapeutic study.

  20. Facilitators and Barriers to Adopting Robotic-Assisted Surgery: Contextualizing the Unified Theory of Acceptance and Use of Technology

    PubMed Central

    BenMessaoud, Christine; Kharrazi, Hadi; MacDorman, Karl F.

    2011-01-01

    Robotic-assisted surgical techniques are not yet well established among surgeon practice groups beyond a few surgical subspecialties. To help identify the facilitators and barriers to their adoption, this belief-elicitation study contextualized and supplemented constructs of the unified theory of acceptance and use of technology (UTAUT) in robotic-assisted surgery. Semi-structured individual interviews were conducted with 21 surgeons comprising two groups: users and nonusers. The main facilitators to adoption were Perceived Usefulness and Facilitating Conditions among both users and nonusers, followed by Attitude Toward Using Technology among users and Extrinsic Motivation among nonusers. The three main barriers to adoption for both users and nonusers were Perceived Ease of Use and Complexity, Perceived Usefulness, and Perceived Behavioral Control. This study's findings can assist surgeons, hospital and medical school administrators, and other policy makers on the proper adoption of robotic-assisted surgery and can guide future research on the development of theories and framing of hypotheses. PMID:21283719

  1. Technical and instrumental prerequisites for single-port laparoscopic solo surgery: state of art.

    PubMed

    Kim, Say-June; Lee, Sang Chul

    2015-04-21

    With the aid of advanced surgical techniques and instruments, single-port laparoscopic surgery (SPLS) can be accomplished with just two surgical members: an operator and a camera assistant. Under these circumstances, the reasonable replacement of a human camera assistant by a mechanical camera holder has resulted in a new surgical procedure termed single-port solo surgery (SPSS). In SPSS, the fixation and coordinated movement of a camera held by mechanical devices provides fixed and stable operative images that are under the control of the operator. Therefore, SPSS primarily benefits from the provision of the operator's eye-to-hand coordination. Because SPSS is an intuitive modification of SPLS, the indications for SPSS are the same as those for SPLS. Though SPSS necessitates more actions than the surgery with a human assistant, these difficulties seem to be easily overcome by the greater provision of static operative images and the need for less lens cleaning and repositioning of the camera. When the operation is expected to be difficult and demanding, the SPSS process could be assisted by the addition of another instrument holder besides the camera holder.

  2. Dexterity optimization by port placement in robot-assisted minimally invasive surgery

    NASA Astrophysics Data System (ADS)

    Selha, Shaun; Dupont, Pierre; Howe, Robert D.; Torchiana, David F.

    2002-02-01

    A computer-based algorithm has been developed which uses preoperative images to provide a surgeon with a list of feasible port triplets ranked according to tool dexterity and endoscopic view quality at each surgical site involved in a procedure. A computer simulation allows the surgeon to select from among the proposed port locations. The procedure selected for the development of the system consists of a coronary artery bypass graft (CABG). In this procedure, the interior mammary artery (IMA) is mobilized from the interior chest wall, and one end is attached to the coronary arteries to provide a new blood supply for the heart. Approximately 10-20 cm is dissected free, using blunt dissection and a harmonic scalpel or electrocautery. At present, the port placement system is being evaluated in clinical trials.

  3. Preclinical study of transcervical upper mediastinal dissection for esophageal malignancy by robot-assisted surgery.

    PubMed

    Mori, Kazuhiko; Yoshimura, Shuntaro; Yamagata, Yukinori; Aikou, Susumu; Seto, Yasuyuki

    2017-06-01

    Robotic surgical systems are potentially applicable to transcervical mediastinal lymph dissection for esophageal malignancy. Robot-assisted surgery was performed on a male fresh-frozen human cadaver. Devices for single-port laparoscopic surgery were deployed via one small incision in the left clavicular area. The task for the robot-assisted surgery was the upper mediastinal dissection to the level of the left main bronchus and en bloc harvest of the lymph nodes adherent to the left recurrent laryngeal nerve. An up-angled 30° scope in the 6 o'clock port and two robotic arms from the 3 and 9 o'clock ports worked effectively together. No collisions of the devices inside the cadaveric body or unexpected traumatic events occurred. The robotic surgical system can be used safely for the upper mediastinal dissection. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  4. Intraoperative on-the-fly organ-mosaicking for laparoscopic surgery

    NASA Astrophysics Data System (ADS)

    Bodenstedt, S.; Reichard, D.; Suwelack, S.; Wagner, M.; Kenngott, H.; Müller-Stich, B.; Dillmann, R.; Speidel, S.

    2015-03-01

    The goal of computer-assisted surgery is to provide the surgeon with guidance during an intervention using augmented reality (AR). To display preoperative data correctly, soft tissue deformations that occur during surgery have to be taken into consideration. Optical laparoscopic sensors, such as stereo endoscopes, can produce a 3D reconstruction of single stereo frames for registration. Due to the small field of view and the homogeneous structure of tissue, reconstructing just a single frame in general will not provide enough detail to register and update preoperative data due to ambiguities. In this paper, we propose and evaluate a system that combines multiple smaller reconstructions from different viewpoints to segment and reconstruct a large model of an organ. By using GPU-based methods we achieve near real-time performance. We evaluated the system on an ex-vivo porcine liver (4.21mm+/- 0.63) and on two synthetic silicone livers (3.64mm +/- 0.31 and 1.89mm +/- 0.19) using three different methods for estimating the camera pose (no tracking, optical tracking and a combination).

  5. Outcome in patient-specific PEEK cranioplasty: A two-center cohort study of 40 implants.

    PubMed

    Jonkergouw, J; van de Vijfeijken, S E C M; Nout, E; Theys, T; Van de Casteele, E; Folkersma, H; Depauw, P R A M; Becking, A G

    2016-09-01

    The best material choice for cranioplasty following craniectomy remains a subject to discussion. Complication rates after cranioplasty tend to be high. Computer-assisted 3-dimensional modelling of polyetheretherketone (PEEK) was recently introduced for cranial reconstruction. The aim of this study was to evaluate patient- and surgery-related characteristics and risk factors that predispose patients to cranioplasty complications. This retrospective study included a total of 40 cranial PEEK implants in 38 patients, performed at two reference centers in the Netherlands from 2011 to 2014. Complications were registered and patient- and surgery-related data were carefully analysed. The overall complication rate of PEEK cranioplasty was 28%. Complications included infection (13 %), postoperative haematoma (10 %), cerebrospinal fluid leak (2.5 %) and wound-related problems (2.5 %). All postoperative infections required removal of the implant. Nonetheless removed implants could be successfully re-used after re-sterilization. Although overall complication rates after PEEK cranioplasty remain high, outcomes are satisfactory, as our results compare favourably to recent literature reports on cranial vault reconstruction. Copyright © 2016 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  6. Hepatoid adenocarcinoma of the lung without production of α-fetoprotein: A case report and review of the literature

    PubMed Central

    SUN, JI NING; ZHANG, BAO LONG; LI, LIN KUN; YU, HAI YAN; WANG, BIN

    2016-01-01

    Hepatoid adenocarcinoma of the lung (HAL) is a rare type of extrahepatic hepatoid adenocarcinoma. The majority of such cases that have been reported in the English literature have demonstrated elevated serum α-fetoprotein (AFP) and/or positive AFP expression on histopathological analysis, and have had poor prognoses. The current study reports an extremely rare case of HAL in the right upper lung without AFP production in a 59-year-old male patient. The patient underwent radical right upper lobectomy via video assisted thoracoscopic surgery. No signs of local recurrence or distant metastasis have been observed for 23 months after the surgery. The serum AFP level following surgery remained within the normal range. Although the diagnosis of HAL predominantly depends on pathological examination, a review of the literature demonstrates that HAL has certain characteristic features with regard to its clinical and computed tomography findings and prognoses, and clinicians should be aware that clinicians should be aware that monitoring serum AFP levels, as well as CT findings, remains important. PMID:27347123

  7. Hepatoid adenocarcinoma of the lung without production of α-fetoprotein: A case report and review of the literature.

    PubMed

    Sun, Ji Ning; Zhang, Bao Long; Li, Lin Kun; Yu, Hai Yan; Wang, Bin

    2016-07-01

    Hepatoid adenocarcinoma of the lung (HAL) is a rare type of extrahepatic hepatoid adenocarcinoma. The majority of such cases that have been reported in the English literature have demonstrated elevated serum α-fetoprotein (AFP) and/or positive AFP expression on histopathological analysis, and have had poor prognoses. The current study reports an extremely rare case of HAL in the right upper lung without AFP production in a 59-year-old male patient. The patient underwent radical right upper lobectomy via video assisted thoracoscopic surgery. No signs of local recurrence or distant metastasis have been observed for 23 months after the surgery. The serum AFP level following surgery remained within the normal range. Although the diagnosis of HAL predominantly depends on pathological examination, a review of the literature demonstrates that HAL has certain characteristic features with regard to its clinical and computed tomography findings and prognoses, and clinicians should be aware that clinicians should be aware that monitoring serum AFP levels, as well as CT findings, remains important.

  8. Microvascular anastomosis guidance and evaluation using real-time three-dimensional Fourier-domain Doppler optical coherence tomography

    PubMed Central

    Ibrahim, Zuhaib; Tong, Dedi; Zhu, Shan; Mao, Qi; Pang, John; Andrew Lee, Wei Ping; Brandacher, Gerald; Kang, Jin U.

    2013-01-01

    Abstract. Vascular and microvascular anastomoses are critical components of reconstructive microsurgery, vascular surgery, and transplant surgery. Intraoperative surgical guidance using a surgical imaging modality that provides an in-depth view and three-dimensional (3-D) imaging can potentially improve outcome following both conventional and innovative anastomosis techniques. Objective postoperative imaging of the anastomosed vessel can potentially improve the salvage rate when combined with other clinical assessment tools, such as capillary refill, temperature, blanching, and skin turgor. Compared to other contemporary postoperative monitoring modalities—computed tomography angiograms, magnetic resonance (MR) angiograms, and ultrasound Doppler—optical coherence tomography (OCT) is a noninvasive high-resolution (micron-level), high-speed, 3-D imaging modality that has been adopted widely in biomedical and clinical applications. For the first time, to the best of our knowledge, the feasibility of real-time 3-D phase-resolved Doppler OCT (PRDOCT) as an assisted intra- and postoperative imaging modality for microvascular anastomosis of rodent femoral vessels is demonstrated, which will provide new insights and a potential breakthrough to microvascular and supermicrovascular surgery. PMID:23856833

  9. [Video-assisted thoracic surgery to treat spinal deformities: climbing the learning curve].

    PubMed

    Rivo Vázquez, José Eduardo; Cañizares Carretero, Miguel Angel; García Fontán, Eva; Blanco Ramos, Montserrat; Varela Ares, Ermitas; Justo Tarrazo, César

    2007-04-01

    The aim of this study was to analyze the impact of the learning curve on the preliminary results of video-assisted thoracic surgery for spinal deformities in a general hospital setting. We retrospectively reviewed the medical records of 15 patients who underwent video-assisted thoracic surgery performed by a multidisciplinary team comprising orthopedic and thoracic surgeons. Endoscopic anterior release and fusion were followed by posterior instrumentation in a single procedure. Demographic, orthopedic, morbidity, and mortality statistics were compiled for the 15 patients and compared to results reported for similar series. Endoscopic surgery was indicated for 15 patients: 11 women (73.3%) and 4 men (26.7%). The median age was 15 years (interquartile range [IQR], 14-19 years). Three patients (20%) required conversion to thoracotomy. There were 2 serious (13.3%) and 3 minor complications (20%). They all resolved satisfactorily and there was no perioperative mortality. The median Cobb angle was 71 degrees (IQR, 63.75 degrees -75.25 degrees ) before surgery and 41 degrees (IQR, 30 degrees -50 degrees ) after surgery. Median duration of surgery was 360 minutes (IQR, 300-360 minutes), duration of postoperative recovery unit stay was 1.5 days (IQR, 1-2.75 days), and total hospital stay was 11.5 days (IQR, 8.25-14 days). Despite the complexity of video-assisted thoracic surgical procedures, we believe they will become the standard approach to treating spinal deformities in the near future. By working together in general hospital settings, orthopedic and thoracic surgeons can help to overcome the steep yet manageable learning curve.

  10. The place of reconstructive tubal surgery in the era of assisted reproductive techniques.

    PubMed

    Gomel, Victor

    2015-12-01

    Assisted reproductive techniques yield high rates of success for women with tubal factor infertility. Because they are potentially effective for all categories of infertility, for two decades, clinical and basic research in infertility has been focused on IVF techniques and outcomes, rather than developing surgical techniques or training infertility subspecialists in tubal microsurgery. Nonetheless, in comparison with IVF, reconstructive tubal surgery is inexpensive and offers multiple opportunities to attempt conception. Performing laparoscopic salpingostomy prior to IVF in women with good prognosis tubal disease may improve the outcome of subsequent IVF, while offering the potential for spontaneous conception. Tubo-tubal anastomosis for reversal of tubal ligation, performed either by a microsurgical technique through a mini-laparotomy or by laparoscopy, is preferable to IVF in younger women with no other fertility factors, because it offers potentially higher cumulative pregnancy rates. Surgery is the only alternative for women with tubal factor infertility who for personal or other reasons are unable to undergo assisted reproductive techniques. Tubal reconstructive surgery and assisted reproductive techniques must be considered complementary forms of treatment for women with tubal factor infertility, and training in tubal reconstructive surgery should be an integral part of subspecialty training in reproductive endocrinology and infertility. Copyright © 2015 Reproductive Healthcare Ltd. Published by Elsevier Ltd. All rights reserved.

  11. Perioperative pain after robot-assisted versus laparoscopic rectal resection.

    PubMed

    Tolstrup, Rikke; Funder, Jonas Amstrup; Lundbech, Liselotte; Thomassen, Niels; Iversen, Lene Hjerrild

    2018-03-01

    In order to improve the surgical treatment of rectal cancer, robot-assisted laparoscopy has been introduced. The robot has gained widespread use; however, the scientific basis for treatment of rectal cancer is still unclear. The aim of this study was to investigate whether robot-assisted laparoscopic rectal resection cause less perioperative pain than standard laparoscopic resection measured by the numerical rating scale (NRS score) as well as morphine consumption. Fifty-one patients were randomized to either laparoscopic or robot-assisted rectal resection at the Department of Surgery at Aarhus University Hospital in Denmark. The intra-operative analgetic consumption was recorded prospectively and registered in patient records. Likewise all postoperative medicine administration including analgesia was recorded prospectively at the hospital medical charts. All morphine analogues were converted into equivalent oral morphine by a converter. Postoperative pain where measured by numeric rating scale (NRS) every hour at the postoperative care unit and three times a day at the ward. Opioid consumption during operation was significantly lower during robotic-assisted surgery than during laparoscopic surgery (p=0.0001). However, there were no differences in opioid consumption or NRS in the period of recovery. We found no differences in length of surgery between the two groups; however, ten patients from the laparoscopic group underwent conversion to open surgery compared to one from the robotic group (p=0.005). No significant difference between groups with respect to complications where found. In the present study, we found that patients who underwent rectal cancer resection by robotic technique needed less analgetics during surgery than patients operated laparoscopically. We did, however, not find any difference in postoperative pain score or morphine consumption postoperatively between the robotic and laparoscopic group.

  12. Effects of realistic force feedback in a robotic assisted minimally invasive surgery system.

    PubMed

    Moradi Dalvand, Mohsen; Shirinzadeh, Bijan; Nahavandi, Saeid; Smith, Julian

    2014-06-01

    Robotic assisted minimally invasive surgery systems not only have the advantages of traditional laparoscopic procedures but also restore the surgeon's hand-eye coordination and improve the surgeon's precision by filtering hand tremors. Unfortunately, these benefits have come at the expense of the surgeon's ability to feel. Several research efforts have already attempted to restore this feature and study the effects of force feedback in robotic systems. The proposed methods and studies have some shortcomings. The main focus of this research is to overcome some of these limitations and to study the effects of force feedback in palpation in a more realistic fashion. A parallel robot assisted minimally invasive surgery system (PRAMiSS) with force feedback capabilities was employed to study the effects of realistic force feedback in palpation of artificial tissue samples. PRAMiSS is capable of actually measuring the tip/tissue interaction forces directly from the surgery site. Four sets of experiments using only vision feedback, only force feedback, simultaneous force and vision feedback and direct manipulation were conducted to evaluate the role of sensory feedback from sideways tip/tissue interaction forces with a scale factor of 100% in characterising tissues of varying stiffness. Twenty human subjects were involved in the experiments for at least 1440 trials. Friedman and Wilcoxon signed-rank tests were employed to statistically analyse the experimental results. Providing realistic force feedback in robotic assisted surgery systems improves the quality of tissue characterization procedures. Force feedback capability also increases the certainty of characterizing soft tissues compared with direct palpation using the lateral sides of index fingers. The force feedback capability can improve the quality of palpation and characterization of soft tissues of varying stiffness by restoring sense of touch in robotic assisted minimally invasive surgery operations.

  13. Benign paroxysmal positional vertigo secondary to laparoscopic surgery

    PubMed Central

    Shan, Xizheng; Wang, Amy; Wang, Entong

    2017-01-01

    Objectives: Benign paroxysmal positional vertigo is a common vestibular disorder and it may be idiopathic or secondary to some conditions such as surgery, but rare following laparoscopic surgery. Methods: We report two cases of benign paroxysmal positional vertigo secondary to laparoscopic surgery, one after laparoscopic cholecystectomy in a 51-year-old man and another following laparoscopic hysterectomy in a 60-year-old woman. Results: Both patients were treated successfully with manual or device-assisted canalith repositioning maneuvers, with no recurrence on the follow-up of 6 -18 months. Conclusions: Benign paroxysmal positional vertigo is a rare but possible complication of laparoscopic surgery. Both manual and device-assisted repositioning maneuvers are effective treatments for this condition, with good efficacy and prognosis. PMID:28255446

  14. Exploration of assistive technology for uniform laparoscopic surgery.

    PubMed

    Sato, Masakazu; Koizumi, Minako; Hino, Takahiro; Takahashi, Yu; Nagashima, Natsuki; Itaoka, Nao; Ueshima, Chiharu; Nakata, Maki; Hasumi, Yoko

    2018-02-19

    Laparoscopic surgery is less invasive than open surgery and is now common in various medical fields. However, laparoscopic surgery is more difficult than open surgery and often requires additional time for the operator to achieve mastery. Therefore, we investigated the use of assistive technology for uniform laparoscopic surgery. We used the OpenCV2 library for augmented reality with an ArUco marker to detect and estimate forceps positioning. We used Sense HAT as the gyro sensor. The development platforms used were Mac OS X 10.11.3 and Raspberry Pi 3, model B. By attaching the ArUco marker to the needle holder, we could draw a line vertically to the marker. When the needle was held, a cube could be imagined, and both the needle and lines could be used to determine the appropriate position. By attaching the gyro sensor to the camera, we could detect its angle of rotation. We obtained stabilized images by rotating the image by the detected degrees; this was possible for any camera position. Assistive technology allowed us to obtain consecutive converted images in real time and may be readily applicable to clinical practice. © 2018 Japan Society for Endoscopic Surgery, Asia Endosurgery Task Force and John Wiley & Sons Australia, Ltd.

  15. Short-term outcome of 1,465 computer-navigated primary total knee replacements 2005–2008

    PubMed Central

    2011-01-01

    Background and purpose Improvement of positioning and alignment by the use of computer-assisted surgery (CAS) might improve longevity and function in total knee replacements, but there is little evidence. In this study, we evaluated the short-term results of computer-navigated knee replacements based on data from the Norwegian Arthroplasty Register. Patients and methods Primary total knee replacements without patella resurfacing, reported to the Norwegian Arthroplasty Register during the years 2005–2008, were evaluated. The 5 most common implants and the 3 most common navigation systems were selected. Cemented, uncemented, and hybrid knees were included. With the risk of revision for any cause as the primary endpoint and intraoperative complications and operating time as secondary outcomes, 1,465 computer-navigated knee replacements (CAS) and 8,214 conventionally operated knee replacements (CON) were compared. Kaplan-Meier survival analysis and Cox regression analysis with adjustment for age, sex, prosthesis brand, fixation method, previous knee surgery, preoperative diagnosis, and ASA category were used. Results Kaplan-Meier estimated survival at 2 years was 98% (95% CI: 97.5–98.3) in the CON group and 96% (95% CI: 95.0–97.8) in the CAS group. The adjusted Cox regression analysis showed a higher risk of revision in the CAS group (RR = 1.7, 95% CI: 1.1–2.5; p = 0.02). The LCS Complete knee had a higher risk of revision with CAS than with CON (RR = 2.1, 95% CI: 1.3–3.4; p = 0.004)). The differences were not statistically significant for the other prosthesis brands. Mean operating time was 15 min longer in the CAS group. Interpretation With the introduction of computer-navigated knee replacement surgery in Norway, the short-term risk of revision has increased for computer-navigated replacement with the LCS Complete. The mechanisms of failure of these implantations should be explored in greater depth, and in this study we have not been able to draw conclusions regarding causation. PMID:21504309

  16. Perioperative nurse training in cardiothoracic surgical robotics.

    PubMed

    Connor, M A; Reinbolt, J A; Handley, P J

    2001-12-01

    The exponential growth of OR technology during the past 10 years has placed increased demands on perioperative nurses. Proficiency is required not only in patient care but also in the understanding, operating, and troubleshooting of video systems, computers, and cutting edge medical devices. The formation of a surgical team dedicated to robotically assisted cardiac surgery requires careful selection, education, and hands-on practice. This article details the six-week training process undertaken at Sarasota Memorial Hospital, Sarasota, Fla, which enabled staff members to deliver excellent patient care with a high degree of confidence in themselves and the robotic technology.

  17. Intramedullary nailing: evolutions of femoral intramedullary nailing: first to fourth generations.

    PubMed

    Russell, Thomas A

    2011-12-01

    Intramedullary femoral nailing is the gold standard for femoral shaft fixation but only in the past 27 years. This rapid replacement of closed traction and cast techniques in North America was a controversial and contentious evolution in surgery. As we enter the fourth generation of implant design, capabilities, and surgical technique, it is important to understand the driving forces for this technology. These forces included changes in radiographic imaging capabilities, biomaterial design and computer-assisted manufacturing, and the recognition of the importance of mobilization of the trauma patient to avoid systemic complications and optimize functional recovery.

  18. A study of an assisting robot for mandible plastic surgery based on augmented reality.

    PubMed

    Shi, Yunyong; Lin, Li; Zhou, Chaozheng; Zhu, Ming; Xie, Le; Chai, Gang

    2017-02-01

    Mandible plastic surgery plays an important role in conventional plastic surgery. However, its success depends on the experience of the surgeons. In order to improve the effectiveness of the surgery and release the burden of surgeons, a mandible plastic surgery assisting robot, based on an augmented reality technique, was developed. Augmented reality assists surgeons to realize positioning. Fuzzy control theory was used for the control of the motor. During the process of bone drilling, both the drill bit position and the force were measured by a force sensor which was used to estimate the position of the drilling procedure. An animal experiment was performed to verify the effectiveness of the robotic system. The position error was 1.07 ± 0.27 mm and the angle error was 5.59 ± 3.15°. The results show that the system provides a sufficient accuracy with which a precise drilling procedure can be performed. In addition, under the supervision's feedback of the sensor, an adequate safety level can be achieved for the robotic system. The system realizes accurate positioning and automatic drilling to solve the problems encountered in the drilling procedure, providing a method for future plastic surgery.

  19. Multicentric evaluation of the impact of central tumour location when comparing rates of N1 upstaging in patients undergoing video-assisted and open surgery for clinical Stage I non-small-cell lung cancer.

    PubMed

    Decaluwé, Herbert; Petersen, René Horsleben; Brunelli, Alex; Pompili, Cecilia; Seguin-Givelet, Agathe; Gust, Lucile; Aigner, Clemens; Falcoz, Pierre-Emmanuel; Rinieri, Philippe; Augustin, Florian; Sokolow, Youri; Verhagen, Ad; Depypere, Lieven; Papagiannopoulos, Kostas; Gossot, Dominique; D'Journo, Xavier Benoit; Guerrera, Francesco; Baste, Jean-Marc; Schmid, Thomas; Stanzi, Alessia; Van Raemdonck, Dirk; Bardet, Jeremy; Thomas, Pascal-Alexandre; Massard, Gilbert; Fieuws, Steffen; Moons, Johnny; Dooms, Christophe; De Leyn, Paul; Hansen, Henrik Jessen

    2017-09-27

    Large retrospective series have indicated lower rates of cN0 to pN1 nodal upstaging after video-assisted thoracic surgery (VATS) compared with open resections for Stage I non-small-cell lung cancer (NSCLC). The objective of our multicentre study was to investigate whether the presumed lower rate of N1 upstaging after VATS disappears after correction for central tumour location in a multivariable analysis. Consecutive patients operated for PET-CT based clinical Stage I NSCLC were selected from prospectively managed surgical databases in 11 European centres. Central tumour location was defined as contact with bronchovascular structures on computer tomography and/or visibility on standard bronchoscopy. Eight hundred and ninety-five patients underwent pulmonary resection by VATS (n = 699, 9% conversions) or an open technique (n = 196) in 2014. Incidence of nodal pN1 and pN2 upstaging was 8% and 7% after VATS and 15% and 6% after open surgery, respectively. pN1 was found in 27% of patients with central tumours. Less central tumours were operated on by VATS compared with the open technique (12% vs 28%, P < 0.001). Logistic regression analysis showed that only tumour location had a significant impact on N1 upstaging (OR 6.2, confidence interval 3.6-10.8; P < 0.001) and that the effect of surgical technique (VATS versus open surgery) was no longer significant when accounting for tumour location. A quarter of patients with central clinical Stage I NSCLC was upstaged to pN1 at resection. Central tumour location was the only independent factor associated with N1 upstaging, undermining the evidence for lower N1 upstaging after VATS resections. Studies investigating N1 upstaging after VATS compared with open surgery should be interpreted with caution due to possible selection bias, i.e. relatively more central tumours in the open group with a higher chance of N1 upstaging. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  20. Seven years of clinical experience with teleconsultation in craniomaxillofacial surgery.

    PubMed

    Ewers, Rolf; Schicho, Kurt; Wagner, Arne; Undt, Gerhard; Seemann, Rudolf; Figl, Michael; Truppe, Michael

    2005-10-01

    In this work the experiences from 50 telemedically supported treatments in craniomaxillofacial surgery are summarized and different setups for their technical realization are described. Furthermore, for the first time the innovative UMTS (universal mobile telecommunication system) is applied for the transmission of arthroscopic videos of the temporomandibular joint and other craniomaxillofacial structures. The combination of computer-assisted navigation technology in augmented reality environments with telecommunication is used for execution of interactive stereotaxic teleconsultation. Furthermore, treatments without navigation are telemedically supported. This study is composed of 4 technical system configurations: 1) integrated services digital network (ISDN)-based videoconferencing without remote control of the navigation computer; 2) transmission control protocol/internet protocol (TCP/IP)-based interactive teleconsultation via bundled ISDN lines (including remote control of the navigation computer); 3) TCP/IP-based interactive teleconsultation via network; 4) combination of TCP/IP-connection and ISDN-based videoconferencing. The telemedically supported treatments are: orbitozygomatic osteotomies, positioning of the mandibular condyle in orthognathic surgery, insertion of implants, positioning of the maxilla in orthognathic surgery, distraction osteogenesis, arthroscopies of the temporomandibular joint, and operation simulations on stereolithographic models. The surgical interventions are evaluated on a 5-level system performance scale from the technical point of view. In a separate trial 20 videosequences of arthroscopies of the temporomandibular joint are transmitted via UMTS cellular phones and independently evaluated by 3 experts (ie, a total of 60 streamings) to investigate feasibility of this technology in the field of craniomaxillofacial surgery. In the years from 1996 to 2002 a total of 50 treatments were telemedically supported. All intraoperative applications were successfully finished; 48 of 60 UMTS transmissions were finished without any interruptions in constant quality, slight interruptions were observed in 8 tests, and a complete breakdown was observed during 4 streamings that required a restart of the transmission. Resolution was sufficient to diagnose even tiny anatomic structures inside the temporomandibular joint, but orientation was hardly recognizable. In many applications telecommunication technology can contribute to a quality improvement in cranio- and maxillofacial surgery because of the global availability of specialized knowledge. The required technical expenditure for teleconsultation crucially depends on the infrastructure that is already available at the clinic and the remote site. UMTS is a promising technology with the potential to be valuable in numerous craniomaxillofacial applications.

  1. Use of near infrared fluorescence during robot-assisted laparoscopic partial nephrectomy.

    PubMed

    Cornejo-Dávila, V; Nazmy, M; Kella, N; Palmeros-Rodríguez, M A; Morales-Montor, J G; Pacheco-Gahbler, C

    2016-04-01

    Partial nephrectomy is the treatment of choice for T1a tumours. The open approach is still the standard method. Robot-assisted laparoscopic surgery offers advantages that are applicable to partial nephrectomy, such as the use of the Firefly® system with near-infrared fluorescence. To demonstrate the implementation of fluorescence in nephron-sparing surgery. This case concerned a 37-year-old female smoker, with obesity. The patient had a right kidney tumour measuring 31 mm, which was found using tomography. She therefore underwent robot-assisted laparoscopic partial nephrectomy, with a warm ischaemia time of 22 minutes and the use of fluorescence with the Firefly® system to guide the resection. There were no complications. The tumour was a pT1aN0M0 renal cell carcinoma, with negative margins. Robot-assisted renal laparoscopic surgery is employed for nephron-sparing surgery, with good oncological and functional results. The combination of the Firefly® technology and intraoperative ultrasound can more accurately delimit the extent of the lesion, increase the negative margins and decrease the ischaemia time. Near-infrared fluorescence in robot-assisted partial nephrectomy is useful for guiding the tumour resection and can potentially improve the oncological and functional results. Copyright © 2015 AEU. Publicado por Elsevier España, S.L.U. All rights reserved.

  2. Video-assisted thoracoscopic surgery for posttraumatic hemothorax in the very elderly.

    PubMed

    Schweigert, Michael; Beron, Martin; Dubecz, Attila; Stadlhuber, Rudolf; Stein, Hubert

    2012-10-01

    Thoracic injury is a life-threatening condition with advanced age being an independent risk factor for both higher morbidity and mortality. Furthermore, elderly patients often have severe comorbidity and in case of chest trauma with rib fractures and hemothorax, their clinical condition is likely to deteriorate fast. Aim of this study is to investigate the feasibility and results of video-assisted thoracoscopy for the treatment of posttraumatic hemothorax in very elderly patients of 80 years or more. The outcomes of 60 consecutive patients who received video-assisted thoracoscopic surgery for posttraumatic hemothorax in a German tertiary referral hospital between 2006 and 2010 were reviewed in a retrospective case study. Patients older than 80 years were identified. There were 39 male and 21 female patients. The median age was 63.2 years. The in-hospital-mortality was 1.7% (1/60). Fifteen of the 60 patients were 80 years or older (80-91). Main reason for hemothorax was blunt chest trauma. Altogether 23 patients had fractures of three or more ribs including six octogenarians. Elderly patients suffered from preexisting cardiopulmonary disease and were often referred to the thoracic surgeon with considerable delay. Video-assisted thoracoscopic surgery was feasible and all octogenarian patients finally recovered well without in-hospital-mortality. Video-assisted thoracoscopic surgery for treatment of posttraumatic hemothorax shows excellent results in very elderly patients of 80 years or more. Despite severe comorbidity and often delayed surgery all patients recovered. We therefore conclude that advanced age is no contraindication for surgical management of posttraumatic hemothorax by means of video-assisted thoracoscopy. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  3. Handheld single photon emission computed tomography (handheld SPECT) navigated video-assisted thoracoscopic surgery of computer tomography-guided radioactively marked pulmonary lesions.

    PubMed

    Müller, Joachim; Putora, Paul Martin; Schneider, Tino; Zeisel, Christoph; Brutsche, Martin; Baty, Florent; Markus, Alexander; Kick, Jochen

    2016-09-01

    Radioactive marking can be a valuable extension to minimally invasive surgery. The technique has been clinically applied in procedures involving sentinel lymph nodes, parathyroidectomy as well as interventions in thoracic surgery. Improvements in equipment and techniques allow one to improve the limits. Pulmonary nodules are frequently surgically removed for diagnostic or therapeutic reasons; here video-assisted thoracoscopic surgery (VATS) is the preferred technique. VATS might be impossible with nodules that are small or located deep in the lung. In this study, we examined the clinical application and safety of employing the newly developed handheld single photon emission tomography (handheld SPECT) device in combination with CT-guided radioactive marking of pulmonary nodules. In this pilot study, 10 subjects requiring surgical resection of a pulmonary nodule were included. The technique involved CT-guided marking of the target nodule with a 20-G needle, with subsequent injection of 25-30 MBq (effective: 7-14 MBq) Tc-99m MAA (Macro Albumin Aggregate). Quality control was made with conventional SPECT-CT to confirm the correct localization and exclude possible complications related to the puncture procedure. VATS was subsequently carried out using the handheld SPECT to localize the radioactivity intraoperatively and therefore the target nodule. A 3D virtual image was superimposed on the intraoperative visual image for surgical guidance. In 9 of the 10 subjects, the radioactive application was successfully placed directly in or in the immediate vicinity of the target nodule. The average size of the involved nodules was 9 mm (range 4-15). All successfully marked nodules were subsequently completely excised (R0) using VATS. The procedure was well tolerated. An asymptomatic clinically insignificant pneumothorax occurred in 5 subjects. Two subjects were found to have non-significant discrete haemorrhage in the infiltration canal of the needle. In a single subject, the radioactive marking was unsuccessful because the radioactivity spread into the pleural space. In our series of 10 patients, it was demonstrated that using handheld SPECT in conjunction with VATS to remove radioactively marked pulmonary nodules is feasible. The combination of proven surgical techniques with a novel localization device (handheld SPECT) allowed successful VATS excision of pulmonary nodules which, due to their localization and small size, would typically have required thoracotomy. ClinicalTrials.gov, NCT02050724, Public 01/29/214, Joachim Müller. © The Author 2016. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  4. Retrospective Analysis on Survival Rate, Template-Related Complications, and Prevalence of Peri-implantitis of 694 Anodized Implants Placed Using Computer-Guided Surgery: Results Between 1 and 10 Years of Follow-Up.

    PubMed

    Tallarico, Marco; Meloni, Silvio Mario

    To report survival rate, early surgical template-related complications, and prevalence of peri-implantitis of dental implants placed in private practices using computer-guided, template-assisted surgery and followed between 1 and 10 years. The present retrospective multicenter study evaluated data collected from fully or partially edentulous patients, with anodized-surface implants placed using computer-guided, template-assisted surgery between January 2006 and December 2015. The outcome measures were implant cumulative survival rate (CSR), early surgical complications involving the surgical template, and prevalence of peri-implantitis. A total of 694 implants were placed in 141 patients. Ten patients (7.1%) with 48 implants (6.9%) dropped out during the study period. One hundred seventeen patients, who received 121 surgical and prosthetic procedures, were treated according to a double-scan protocol, while the remaining 24 patients were treated by using the integrated treatment workflow. Most of the implants were immediately loaded (528 implants, 76.1%; 112 patients, 79.4%). Overall, 107 complete full-arch restorations (supported by four to eight implants each) were delivered in 103 patients (73%) with 595 implants (85.7%), while 13 single and 30 partial restorations (two to five implants each) were delivered in 38 patients (27%) with 99 implants (14.3%). Patients were followed for up to 10 years (mean: 58.2 months, range: 12 to 120 months). Implant- and patient-level CSR (Kaplan-Meier estimation) at the 10-year follow-up was 97.4% (95% CI: 1.0309 to 0.9161) and 92.1% (95% CI: 1.1575 to 0.6836), respectively. All failed implants were lost before definitive prosthesis delivery (early failure). Ten (7.1%) minor template-related complications were experienced and resolved chairside. Over the entire follow-up period, four patients (2.8%) with 12 implants (1.7%) showed signs of peri-implantitis at the 1- (four implants), 2- (four implants), and 4-year (four implants) visits. High long-term survival rates and low complications and prevalence of peri-implantitis were observed for a large cohort of anodized-surface implants placed in private practices. Further studies are needed to confirm these preliminary results.

  5. Mandibular reconstruction with the vascularized fibula flap: comparison of virtual planning surgery and conventional surgery.

    PubMed

    Wang, Y Y; Zhang, H Q; Fan, S; Zhang, D M; Huang, Z Q; Chen, W L; Ye, J T; Li, J S

    2016-11-01

    This study evaluated the accuracy of mandibular reconstruction and assessed clinical outcomes in both virtual planning and conventional surgery patients. ProPlan CMF surgical planning software was used preoperatively in the virtual planning group. In the virtual planning group, fibula flaps were harvested and osteotomized, and the mandibles were resected and reconstructed assisted by the prefabricated cutting guides and templates. The main outcome measures included the operative time, postoperative computed tomography (CT) scans, facial appearance, and occlusal function. The ischemia time and total operation time were shorter in the virtual planning group than in the conventional surgery group. High precision with the use of the cutting guides and templates was found for both the fibula and mandible, and a good fit was noted among the pre-bent plate, mandible, and fibula segments in the virtual planning group. Postoperative CT scans also showed excellent mandibular contours of the fibula flaps in accordance with virtual plans in the virtual planning group. This study demonstrated that virtual surgical planning was able to achieve more accurate mandibular reconstruction than conventional surgery. The use of prefabricated cutting guides and plates makes fibula flap moulding and placement easier, minimizes the operating time, and improves clinical outcomes. Copyright © 2016 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  6. Does robotic assistance confer an economic benefit during laparoscopic radical nephrectomy?

    PubMed

    Yang, David Y; Monn, M Francesca; Bahler, Clinton D; Sundaram, Chandru P

    2014-09-01

    While robotic assisted radical nephrectomy is safe with outcomes and complication rates comparable to those of the pure laparoscopic approach, there is little evidence of an economic or clinical benefit. From the 2009 to 2011 Nationwide Inpatient Sample database we identified patients 18 years old or older who underwent radical nephrectomy for primary renal malignancy. Robotic assisted and laparoscopic techniques were noted. Patients treated with the open technique and those with evidence of metastatic disease were excluded from analysis. Descriptive statistics were performed using the chi-square and Mann-Whitney tests, and the Student t-test. Multiple linear regression was done to examine factors associated with increased hospital costs and charges. We identified 24,312 radical nephrectomy cases for study inclusion, of which 7,787 (32%) were performed robotically. There was no demographic difference between robotic assisted and pure laparoscopic radical nephrectomy cases. Median total charges were $47,036 vs $38,068 for robotic assisted vs laparoscopic surgery (p <0.001). Median total hospital costs for robotic assisted surgery were $15,149 compared to $11,735 for laparoscopic surgery (p <0.001). There was no difference in perioperative complications or the incidence of death. Compared to the laparoscopic approach robotic assistance conferred an estimated $4,565 and $11,267 increase in hospital costs and charges, respectively, when adjusted for adapted Charlson comorbidity index score, perioperative complications and length of stay (p <0.001). Robotic assisted radical nephrectomy results in increased medical expense without improving patient morbidity. Assuming surgeon proficiency with pure laparoscopy, robotic technology should be reserved primarily for complex surgeries requiring reconstruction. Traditional laparoscopic techniques should continue to be used for routine radical nephrectomy. Copyright © 2014 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  7. RapidSplint: virtual splint generation for orthognathic surgery - results of a pilot series.

    PubMed

    Adolphs, Nicolai; Liu, Weichen; Keeve, Erwin; Hoffmeister, Bodo

    2014-01-01

    Within the domain of craniomaxillofacial surgery, orthognathic surgery is a special field dedicated to the correction of dentofacial anomalies resulting from skeletal malocclusion. Generally, in such cases, an interdisciplinary orthodontic and surgical treatment approach is required. After initial orthodontic alignment of the dental arches, skeletal discrepancies of the jaws can be corrected by distinct surgical strategies and procedures in order to achieve correct occlusal relations, as well as facial balance and harmony within individualized treatment concepts. To transfer the preoperative surgical planning and reposition the mobilized dental arches with optimal occlusal relations, surgical splints are typically used. For this purpose, different strategies have been described which use one or more splints. Traditionally, these splints are manufactured by a dental technician based on patient-specific dental casts; however, computer-assisted technologies have gained increasing importance with respect to preoperative planning and its subsequent surgical transfer. In a pilot study of 10 patients undergoing orthognathic corrections by a one-splint strategy, two final occlusal splints were produced for each patient and compared with respect to their clinical usability. One splint was manufactured in the traditional way by a dental technician according to the preoperative surgical planning. After performing a CBCT scan of the patient's dental casts, a second splint was designed virtually by an engineer and surgeon working together, according to the desired final occlusion. For this purpose, RapidSplint, a custom-made software platform, was used. After post-processing and conversion of the datasets into .stl files, the splints were fabricated by the PolyJet procedure using photo polymerization. During surgery, both splints were inserted after mobilization of the dental arches then compared with respect to their clinical usability according to the occlusal fitting. Using the workflow described above, virtual splints could be designed and manufactured for all patients in this pilot study. Eight of 10 virtual splints could be used clinically to achieve and maintain final occlusion after orthognathic surgery. In two cases virtual splints were not usable due to insufficient occlusal fitting, and even two of the traditional splints were not clinically usable. In five patients where both types of splints were available, their occlusal fitting was assessed as being equivalent, and in one case the virtual splint showed even better occlusal fitting than the traditional splint. In one case where no traditional splint was available, the virtual splint proved to be helpful in achieving the final occlusion. In this pilot study it was demonstrated that clinically usable splints for orthognathic surgery can be produced by computer-assisted technology. Virtual splint design was realized by RapidSplint®, an in-house software platform which might contribute in future to shorten preoperative workflows for the production of orthognathic surgical splints.

  8. Ultralow-dose computed tomography imaging for surgery of midfacial and orbital fractures using ASIR and MBIR.

    PubMed

    Widmann, G; Dalla Torre, D; Hoermann, R; Schullian, P; Gassner, E M; Bale, R; Puelacher, W

    2015-04-01

    The influence of dose reductions on diagnostic quality using a series of high-resolution ultralow-dose computed tomography (CT) scans for computer-assisted planning and surgery including the most recent iterative reconstruction algorithms was evaluated and compared with the fracture detectability of a standard cranial emergency protocol. A human cadaver head including the mandible was artificially prepared with midfacial and orbital fractures and scanned using a 64-multislice CT scanner. The CT dose index volume (CTDIvol) and effective doses were calculated using application software. Noise was evaluated as the standard deviation in Hounsfield units within an identical region of interest in the posterior fossa. Diagnostic quality was assessed by consensus reading of a craniomaxillofacial surgeon and radiologist. Compared with the emergency protocol at CTDIvol 35.3 mGy and effective dose 3.6 mSv, low-dose protocols down to CTDIvol 1.0 mGy and 0.1 mSv (97% dose reduction) may be sufficient for the diagnosis of dislocated craniofacial fractures. Non-dislocated fractures may be detected at CTDIvol 2.6 mGy and 0.3 mSv (93% dose reduction). Adaptive statistical iterative reconstruction (ASIR) 50 and 100 reduced average noise by 30% and 56%, and model-based iterative reconstruction (MBIR) by 93%. However, the detection rate of fractures could not be improved due to smoothing effects. Crown Copyright © 2015. Published by Elsevier Ltd. All rights reserved.

  9. Single Incision Laparoscopic Assisted Appendectomy: Experience of 82 Cases

    PubMed Central

    Sinha, Anant Narayan; Deepak, Desh; Pandey, NK; Nandani

    2016-01-01

    Introduction Single Incision Laparoscopic Surgery (SILS) is one of the most recent developments which have been made in the field of minimal assesses surgery. It has potential advantages of less postoperative pain and better cosmesis, but at the same time, this procedure is time consuming and it increases the cost of surgery. Aim In this study, we evaluated the feasibility, safety and potential advantages of single incision laparoscopic assisted appendectomy. Materials and Methods Single incision laparoscopic assisted appendectomy was done in 82 patients who were diagnosed with acute or chronic appendicitis. A single 10mm incision made over right lower quadrant was used for placing two 5mm trocars and appendisectomy was done as in open surgery, after delivering out the appendix from the incision. Results Mean operative time was 32.56 ± 15.5 minutes. Mean post-operative pain scores as per visual analogue scalewere 6.5, 4.2 and 1.2 on 12 hours day 1 and day 2 after surgery respectively. Mean length of hospital stay was 1.4 ± 1.2 days. Conclusion Single incision laparoscopic appendectomy is safe and feasible. PMID:27437295

  10. Refractive eye surgery - what to ask your doctor

    MedlinePlus

    ... surgery; Nearsightedness surgery - what to ask your doctor; LASIK - what to ask your doctor; Laser-Assisted In ... Academy of Ophthalmology. Questions to ask when considering LASIK. San Francisco, CA. American Academy of Ophthalmology. December ...

  11. The impact of new technology on surgery for colorectal cancer

    PubMed Central

    Makin, Gregory B; Breen, David J; Monson, John RT

    2001-01-01

    Advances in technology continue at a rapid pace and affect all aspects of life, including surgery. We have reviewed some of these advances and the impact they are having on the investigation and management of colorectal cancer. Modern endoscopes, with magnifying, variable stiffness and localisation capabilities are making the primary investigation of colonic cancer easier and more acceptable for patients. Imaging investigations looking at primary, metastatic and recurrent disease are shifting to digital data sets, which can be stored, reviewed remotely, potentially fused with other modalities and reconstructed as 3 dimensional (3D) images for the purposes of advanced diagnostic interpretation and computer assisted surgery. They include virtual colonoscopy, trans-rectal ultrasound, magnetic resonance imaging, positron emission tomography and radioimmunoscintigraphy. Once a colorectal carcinoma is diagnosed, the treatment options available are expanding. Colonic stents are being used to relieve large bowel obstruction, either as a palliative measure or to improve the patient’s overall condition before definitive surgery. Transanal endoscopic microsurgery and minimally invasive techniques are being used with similar outcomes and a lower mortality, morbidity and hospital stay than open trans-abdominal surgery. Transanal endoscopic microsurgery allows precise excision of both benign and early malignant lesions in the mid and upper rectum. Survival of patients with inoperable hepatic metastases following radiofrequency ablation is encouraging. Robotics and telemedicine are taking surgery well into the 21st century. Artificial neural networks are being developed to enable us to predict the outcome for individual patients. New technology has a major impact on the way we practice surgery for colorectal cancer. PMID:11819841

  12. Simultaneous bilateral decortications via video-assisted thoracic surgery for bilateral empyema

    PubMed Central

    Nose, Naohiro; Anami, Toshiki

    2014-01-01

    Introduction Bilateral empyema is a rare and life-threatening condition that is difficult to treat. We herein report a case of bilateral empyema that was treated with simultaneous bilateral decortications via video-assisted thoracic surgery (VATS). Presentation of case A 38-year-old female complained of chest pain, dyspnea, and high grade fever lasting two weeks. Computed tomography revealed bilateral notching pleural effusion and pneumonia with atelectasis. Bilateral thoracic drainage was performed. From the right chest, white pus was drained, and Streptococcus anginosus was identified. The left drainage fluid was serous, and no bacteria were identified. We diagnosed the patient with right empyema and left para-pneumonic effusion consequent to pneumonia. Because conservative therapies could not resolve the inflammatory findings, simultaneous bilateral VATS decortications were performed. Both thoracic cavities had loculated pleural effusion. In contrast to the preoperative findings, white pus was found in not only the right, but also the left thoracic cavity. She had an uncomplicated postoperative course and recovered. Discussion Bilateral empyema that has developed to the fibrinopleural phase is difficult to treat with drains alone. Bilateral VATS decortications helped to make a definitive diagnosis and treat both sides simultaneously. Conclusion Simultaneous bilateral VATS decortications should be considered as a feasible and effective procedure for bilateral empyema that is refractory to medical treatment. PMID:25528031

  13. Solitary glandular papilloma of the peripheral lung: a report of two cases

    PubMed Central

    2014-01-01

    Solitary papilloma of the lung is thought to be a rare benign epithelial tumor, and complete surgical resection is currently the standard treatment for this pathology. However, some cases of papilloma have reportedly shown malignant potential. We report two cases of solitary glandular papilloma of the peripheral lung that were treated by thoracoscopic partial resection. The first patient presented with a nodular lesion in the lower lobe of the left lung that was detected on a follow-up chest computed tomography (CT) scan after treatment for laryngeal cancer. Partial lung resection was performed by video-assisted thoracoscopic surgery. In the second patient, a nodular lesion was incidentally identified in the lower lobe of the left lung during a health check-up. Partial lung resection was again performed by video-assisted thoracoscopic surgery. The postoperative course in both cases was uneventful, and no recurrences have been observed as of 44 months and 41 months postoperatively, respectively. To the best of our knowledge, malignant transformation has been reported both with the squamous type and the mixed type of solitary papilloma of the lung. The glandular variant has shown no tendency toward local recurrence after local excision and has no apparent malignant potential. Local excision is thus recommended for solitary glandular papilloma in order to preserve pulmonary function. PMID:24885310

  14. Solitary glandular papilloma of the peripheral lung: a report of two cases.

    PubMed

    Kaseda, Kaoru; Horio, Hirotoshi; Harada, Masahiko; Hishima, Tsunekazu

    2014-05-19

    Solitary papilloma of the lung is thought to be a rare benign epithelial tumor, and complete surgical resection is currently the standard treatment for this pathology. However, some cases of papilloma have reportedly shown malignant potential. We report two cases of solitary glandular papilloma of the peripheral lung that were treated by thoracoscopic partial resection. The first patient presented with a nodular lesion in the lower lobe of the left lung that was detected on a follow-up chest computed tomography (CT) scan after treatment for laryngeal cancer. Partial lung resection was performed by video-assisted thoracoscopic surgery. In the second patient, a nodular lesion was incidentally identified in the lower lobe of the left lung during a health check-up. Partial lung resection was again performed by video-assisted thoracoscopic surgery. The postoperative course in both cases was uneventful, and no recurrences have been observed as of 44 months and 41 months postoperatively, respectively. To the best of our knowledge, malignant transformation has been reported both with the squamous type and the mixed type of solitary papilloma of the lung. The glandular variant has shown no tendency toward local recurrence after local excision and has no apparent malignant potential. Local excision is thus recommended for solitary glandular papilloma in order to preserve pulmonary function.

  15. Transoral videolaryngoscopic surgery for papillary carcinoma arising in lingual thyroid.

    PubMed

    Mogi, Chisato; Shinomiya, Hirotaka; Fujii, Natsumi; Tsuruta, Tomoyuki; Morita, Naruhiko; Furukawa, Tatsuya; Teshima, Masanori; Kanzawa, Maki; Hirokawa, Mitsuyoshi; Otsuki, Naoki; Nibu, Ken-Ichi

    2018-05-15

    Carcinoma arising in lingual thyroid is an extremely rare entity accounting for only 1% of all reported ectopic thyroids. Here, we report a case of carcinoma arising in lingual thyroid, which has been successfully managed by transoral resection and bilateral neck dissections. A lingual mass 4-cm in diameter with calcification was incidentally detected by computed tomography at medical check-up. No thyroid tissue was observed in normal position. Ultrasound examination showed bilateral multiple lymphadenopathies. Fine needle aspiration biopsy from lymph node in his right neck was diagnosed as Class III and thyroglobulin level of the specimen was 459ng/ml. Due to the difficulty in performing FNA of the lingual masses, right neck dissection was performed in advance for diagnostic purpose. Pathological examination showed existence of large and small follicular thyroid tissues in several lymph nodes, suggesting lymph node metastasis from thyroid carcinoma. Two months after the initial surgery, video-assisted transoral resection of lingual thyroid with simultaneous left neck dissection was performed. Postoperative course was uneventful. Papillary carcinoma was found in the lingual thyroid and thyroid tissues were also found in left cervical lymph nodes. Video-assisted transoral resection was useful for the treatment of thyroid cancer arising in lingual thyroid. Copyright © 2018 Elsevier B.V. All rights reserved.

  16. Robot-assisted Surgery for Benign Ureteral Strictures: Experience and Outcomes from Four Tertiary Care Institutions.

    PubMed

    Buffi, Nicolò Maria; Lughezzani, Giovanni; Hurle, Rodolfo; Lazzeri, Massimo; Taverna, Gianluigi; Bozzini, Giorgio; Bertolo, Riccardo; Checcucci, Enrico; Porpiglia, Francesco; Fossati, Nicola; Gandaglia, Giorgio; Larcher, Alessandro; Suardi, Nazareno; Montorsi, Francesco; Lista, Giuliana; Guazzoni, Giorgio; Mottrie, Alexandre

    2017-06-01

    Minimally invasive treatment of benign ureteral strictures is still challenging because of its technical complexity. In this context, robot-assisted surgery may overcome the limits of the laparoscopic approach. To evaluate outcomes for robotic ureteral repair in a multi-institutional cohort of patients treated for ureteropelvic junction obstruction and ureteral stricture (US) at four tertiary referral centres. This retrospective study reports data for 183 patients treated with standard robot-assisted pyeloplasty (PYP) and robotic uretero-ureterostomy (UUY) at four high-volume centres from January 2006 to September 2014. Robotic PYP and robot-assisted UUY were performed according to previously reported surgical techniques. Preoperative, intraoperative, and postoperative variables and outcomes were assessed. A descriptive statistical analysis was performed. No robot-assisted UUY cases required surgical conversion, while 2.8% of PYP cases were not completed robotically. The median operative time was 120 and 150min for robot-assisted PYP and robot-assisted UUY, respectively. No intraoperative complications were reported. The overall complication rate for all procedures was 11% (n=20) and complications were mostly of low grade. The high-grade complication rate was 2.2% (n=4). At median follow-up of 24 mo, the overall success rate was >90% for both procedures. The study limitations include its retrospective nature and the heterogeneity of the study population. Robotic surgery for benign US is safe and effective, with limited risk of high-grade complications and good intermediate-term results. In this study we review the use of robotic surgery at four different tertiary care centres in the treatment of patients affected by benign ureteral strictures. Our results demonstrate that robotic surgery is a safe alternative to the standard open approach in the treatment of ureteral strictures. Copyright © 2016 European Association of Urology. Published by Elsevier B.V. All rights reserved.

  17. Perioperative and mid-term oncologic outcomes of robotic assisted radical cystectomy with totally intracorporeal neobladder: Results of a propensity score matched comparison with open cohort from a single-centre series.

    PubMed

    Simone, Giuseppe; Tuderti, Gabriele; Misuraca, Leonardo; Anceschi, Umberto; Ferriero, Mariaconsiglia; Minisola, Francesco; Guaglianone, Salvatore; Gallucci, Michele

    2018-04-17

    In this study, we compared perioperative and oncologic outcomes of patients treated with either open or robot-assisted radical cystectomy and intracorporeal neobladder at a tertiary care center. The institutional prospective bladder cancer database was queried for "cystectomy with curative intent" and "neobladder". All patients underwent robot-assisted radical cystectomy and intracorporeal neobladder or open radical cystectomy and orthotopic neobladder for high-grade non-muscle invasive bladder cancer or muscle invasive bladder cancer with a follow-up length ≥2 years were included. A 1:1 propensity score matching analysis was used. Kaplan-Meier method was performed to compare oncologic outcomes of selected cohorts. Survival rates were computed at 1,2,3 and 4 years after surgery and the log rank test was applied to assess statistical significance between the matched groups. Overall, 363 patients (299 open and 64 robotic) were included. Open radical cystectomy patients were more frequently male (p = 0.08), with higher pT stages (p = 0.003), lower incidence of urothelial histologies (p = 0.05) and lesser adoption of neoadjuvant chemotherapy (<0.001). After applying the propensity score matching, 64 robot-assisted radical cystectomy patients were matched with 46 open radical cystectomy cases (all p ≥ 0.22). Open cohort showed a higher rate of perioperative overall complications (91.3% vs 42.2%, p 0.001). At Kaplan-Meier analysis robotic and open cohorts displayed comparable disease-free survival (log-rank p = 0.746), cancer-specific survival (p = 0.753) and overall-survival rates (p = 0.909). Robot-assisted radical cystectomy and intracorporeal neobladder provides comparable oncologic outcomes of open radical cystectomy and orthotopic neobladder at intermediate term survival analysis. Copyright © 2018 Elsevier Ltd, BASO ~ The Association for Cancer Surgery, and the European Society of Surgical Oncology. All rights reserved.

  18. Implants for elderly patients.

    PubMed

    Schimmel, Martin; Müller, Frauke; Suter, Valérie; Buser, Daniel

    2017-02-01

    In the developed world, the large birth cohorts of the so-called baby boomer generation have arrived in medical and dental practices. Often, elderly patients are 'young-old' baby boomers in whom partial edentulism is the predominant indication for implant therapy. However, the generation 85+ years of age represents a new challenge for the dental profession, as their lives are frequently dominated by dependency, multimorbidity and frailty. In geriatric implant dentistry, treatment planning is highly individualized, as interindividual differences become more pronounced with age. Nevertheless, there are four typical indications for implant therapy: (i) avoidance of removable partial prostheses; (ii) preservation of existing removable partial prostheses; (iii) stabilization of Kennedy Class I removable partial prostheses; and (iv) stabilization of complete prostheses. From a surgical point of view, two very important aspects must be considered when planning implant surgery in elderly patients: first, the consistent strive to minimize morbidity; and, second, the fact that coexisting medical risk factors are significantly more common in elderly patients. Modern three-dimensional cone beam computed tomography imaging is often indicated in order to plan minimally invasive implant surgery. Computer-assisted implant surgery might allow flapless implant surgery, which offers a low level of postoperative morbidity and a minimal risk of postsurgical bleeding. Short and reduced-diameter implants are now utilized much more often than a decade ago. Two-stage surgical procedures should be avoided in elderly patients. Implant restorations for elderly patients should be designed so that they can be modified to become low-maintenance prostheses, or even be removed, as a strategy to facilitate oral hygiene and comfort in the final stage of life. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  19. Balancing curability and unnecessary surgery in the context of computed tomography screening for lung cancer.

    PubMed

    Flores, Raja; Bauer, Thomas; Aye, Ralph; Andaz, Shahriyour; Kohman, Leslie; Sheppard, Barry; Mayfield, William; Thurer, Richard; Smith, Michael; Korst, Robert; Straznicka, Michaela; Grannis, Fred; Pass, Harvey; Connery, Cliff; Yip, Rowena; Smith, James P; Yankelevitz, David; Henschke, Claudia; Altorki, Nasser

    2014-05-01

    Surgical management is a critical component of computed tomography (CT) screening for lung cancer. We report the results for US sites in a large ongoing screening program, the International Early Lung Cancer Action Program (I-ELCAP). We identified all patients who underwent surgical resection. We compared the results before (1993-2005) and after (2006-2011) termination of the National Lung Screening Trial to identify emerging trends. Among 31,646 baseline and 37,861 annual repeat CT screenings, 492 patients underwent surgical resection; 437 (89%) were diagnosed with lung cancer; 396 (91%) had clinical stage I disease. In the 54 (11%) patients with nonmalignant disease, resection was sublobar in 48 and lobectomy in 6. The estimated cure rate based on the 15-year Kaplan-Meier survival for all 428 patients (excluding 9 typical carcinoids) with lung cancer was 84% (95% confidence interval [CI], 80%-88%) and 88% (95% CI, 83%-92%) for clinical stage I disease resected within 1 month of diagnosis. Video-assisted thoracoscopic surgery and sublobar resection increased significantly, from 10% to 34% (P < .0001) and 22% to 34% (P = .01) respectively; there were no significant differences in the percentage of malignant diagnoses (90% vs 87%, P = .36), clinical stage I (92% vs 89%, P = .33), pathologic stage I (85% vs 82%, P = .44), tumor size (P = .61), or cell type (P = .81). The frequency and extent of surgery for nonmalignant disease can be minimized in a CT screening program and provide a high cure rate for those diagnosed with lung cancer and undergoing surgical resection. Copyright © 2014 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  20. Use of the Femtosecond Lasers in Ophthalmology

    NASA Astrophysics Data System (ADS)

    Roszkowska, Anna M.; Urso, Mario; Signorino, Alberto; Aragona, Pasquale

    2018-01-01

    Femtosecond laser (FSL) is an infrared laser with a wavelength of 1053 nm. FS laser works producing photodisruption or photoionization of the optically transparent tissue such as cornea. Currently FS lasers have a wide range of applications in ophthalmic surgery. They are used above all in corneal surgery in refractive procedures and keratoplasty, and recently in cataract surgery. The use of the FSL in corneal refractive surgery includes LASIK flap creation, astigmatic keratotomy, Femtosecond Lenticule Extraction (FLEx), Small Incision Lenticule Extraction (SMILE) and channels creation for implantation of the intrastromal corneal rings. As to the corneal grafting, the FS lasers are used in laser-assisted anterior and posterior lamellar keratoplasty and customized trephination in the penetrating keratoplasty. FS Laser Assisted Cataract Surgery (FLACS) includes capsulorrhexis and nuclear fragmentation that enhance safety and efficacy of the procedure.

  1. From full thoracotomy to uniportal video-assisted thoracic surgery: lessons learned

    PubMed Central

    Passera, Eliseo

    2017-01-01

    Over the last two decades, conventional video-assisted thoracic surgery (VATS) has established itself as the preferred approach for almost all thoracic surgical procedures. The procedure provides a safe and easy approach with undisputed patient benefit at a cost acceptable to the healthcare system all over the world, in large hospitals as well as underprivileged rural areas. VATS has effectively addressed the patients' right to less scarring, trauma (both of access and intrathoracic manipulation), medication, pain, hospitalization, and early return home and work. These improvements have been further stressed by the introduction of uniportal VATS (uniVATS). Single port surgery is a very exciting new modality in the field of minimal access surgery which aims at further reducing scars of standard vats and towards an hypothetical prospective of scarless surgery. PMID:29078599

  2. Bilateral simultaneous robot-assisted pyelolithotomy for large (>6 cm) kidney stones: technique and review of literature.

    PubMed

    Rajiv, Yadav; Kumar, Abhay; Poonam, Yadav

    2015-09-01

    With wide availability and demonstrable efficacy of endourological techniques, open surgery for renal stone disease has largely been replaced in contemporary urological practice. However, with increasing experience of laparoscopy and robotic surgery in urology, the principle of open renal surgery is being revisited. In certain situations, laparoscopic or robotic pyelolithomy may be an excellent minimally invasive alternative to percutaneous nephrolithomy with its unique advantages. We present a case of bilateral large kidney stones managed with bilateral simultaneous robot-assisted laparoscopic pyelolithotomy with excellent results.

  3. Femtosecond laser-assisted cataract surgery in pediatric patients.

    PubMed

    Corredor-Ortega, Claudia; Gonzalez-Salinas, Roberto; Montero, María José; González-Flores, Rocío; Collura-Merlier, Allan; Cervantes-Coste, Guadalupe; Mendoza-Schuster, Erick; Velasco-Barona, Cecilio

    2018-04-01

    Pediatric cataract surgery poses a significant challenge for the cataract surgeon, in part because an elastic anterior capsule can make capsulorhexis difficult. With the use of femtosecond laser-assisted cataract surgery (FLACS), however, the continuous curvilinear capsulorhexis can be made with predictable size, circular shape, centration, and accuracy. In addition, topical anesthesia can be used for the FLACS docking procedure in cooperative children above 6 years of age, using transparent adhesive polyurethane film segments. Copyright © 2018 American Association for Pediatric Ophthalmology and Strabismus. Published by Elsevier Inc. All rights reserved.

  4. Mycobacterium chimaera left ventricular assist device infections.

    PubMed

    Balsam, Leora B; Louie, Eddie; Hill, Fred; Levine, Jamie; Phillips, Michael S

    2017-06-01

    A global outbreak of invasive Mycobacterium chimaera infections after cardiac surgery has recently been linked to bioaerosols from contaminated heater-cooler units. The majority of cases have occurred after valvular surgery or aortic graft surgery and nearly half have resulted in death. To date, infections in patients with left ventricular assist devices (LVADs) have not been characterized in the literature. We report two cases of device-associated M. chimaera infection in patients with continuous-flow LVADs and describe challenges related to diagnosis and management in this population. © 2017 Wiley Periodicals, Inc.

  5. Computer assisted positioning of the proximal segment after sagittal split osteotomy of the mandible: Preclinical investigation of a novel electromagnetic navigation system.

    PubMed

    Nova, Igor; Kallus, Sebastian; Berger, Moritz; Ristow, Oliver; Eisenmann, Urs; Freudlsperger, Christian; Hoffmann, Jürgen; Dickhaus, Hartmut

    2017-05-01

    Modifications of the temporomandibular joint position after mandible osteotomy are reluctantly accepted in orthognathic surgery. To tackle this problem, we developed a new navigation system using miniaturized electromagnetic sensors. Our imageless navigation approach is therefore optimized to avoid complications of previously proposed optical approaches such as the interference with established surgical procedures and the line of sight problem. High oblique sagittal split osteotomies were performed on 6 plastic skull mandibles in a laboratory under conditions comparable to the operating theatre. The subsequent condyle reposition was guided by an intuitive user interface and performed by electromagnetic navigation. To prove the suitability and accuracy of this novel approach for condyle navigation, the positions of 3 titanium marker screws placed on each of the proximal segments were compared using pre- and postoperative Cone Beam Computed Tomography (CBCT) imaging. Guided by the electromagnetic navigation system, positioning of the condyles was highly accurate in all dimensions. Translational discrepancies up to 0,65 mm and rotations up to 0,38° in mean could be measured postoperatively. There were no statistically significant differences between navigation results and CBCT measurements. The intuitive user interface provides a simple way to precisely restore the initial position and orientation of the proximal mandibular segments. Our electromagnetic navigation system therefore yields a promising approach for orthognathic surgery applications. Copyright © 2017 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  6. [3-dimensional imaging systems: first experience in planning and documentation of plastic surgery procedures].

    PubMed

    Spanholtz, T A; Leitsch, S; Holzbach, T; Volkmer, E; Engelhardt, T; Giunta, R E

    2012-08-01

    A reproducible 3-dimensional photographic system enables plastic surgeons to perform preoperative planning and helps them to understand the patient's expectations. There are a few systems available that allow a reproducible 3-dimensional scans of the patient with direct simulation of the planned procedure. The Vectra Volumetric 3D Surface Imaging® by Canfield® provides such an option and helps the surgeons to document and compare postoperative changes at different time points. Since January 2011 we are digitally documenting all patients receiving form-modulating procedures in our plastic surgery unit. We present the spectrum of clinical implications and discuss advantages and disadvantages of the system. Furthermore, we have studied the accuracy of the system in comparison to direct measurement in 15 volunteers. The system is especially suited for planning and evaluation of breast augmentation, facial aesthetic and reconstructive surgery as well as volumetric measurements before and after liposuction and lipofilling. Computer-assisted measurements correlate with a median deviation of 2.3% with manually measured distances in the face. We found the user-friendly Vectra® system to be a reliable and reproducible device for planning plastic surgery therapies and for documenting postoperative results. © Georg Thieme Verlag KG Stuttgart · New York.

  7. Femtosecond laser-assisted compared with standard cataract surgery for removal of advanced cataracts.

    PubMed

    Hatch, Kathryn M; Schultz, Tim; Talamo, Jonathan H; Dick, H Burkhard

    2015-09-01

    To compare effective phacoemulsification time (EPT) for the removal of brunescent cataracts treated with femtosecond laser-assisted cataract surgery with standard cataract phacoemulsification techniques. Ruhr University Eye Hospital, Bochum, Germany. Comparative prospective case study. The Lens Opacities Classification System III (LOCS III) grading system was used to measure eyes divided into 4 groups having cataract surgery. Groups 1 and 2 contained eyes with LOCS III grade nuclear opalescence (NO) 3 cataracts treated with standard cataract surgery and femtosecond laser-assisted cataract surgery, respectively. Groups 3 and 4 contained brunescent cataracts, LOCS III grades NO5, treated with standard cataract surgery and femtosecond laser-assisted cataract surgery, respectively. There were 240 eyes, with 60 eyes in each group. The EPT in Group 1 ranged from 0.46 to 3.10 (mean 1.38); the EPT in all eyes in Group 2 was 0 (P < .001). The EPT in Groups 3 and 4 was 2.12 to 19.29 (mean 6.85) and 0 to 6.75 (mean 1.35), respectively (P < .001). A comparison between EPT in Groups 1 and 4 showed that EPT in Group 4 was also lower than in Group 1 (P = .013). Groups 4 and 1 were the most statistically similar of all groups compared, suggesting that EPT for a femtosecond laser-treated grade 5 cataract was most similar to that of a standard-treated grade 3 cataract. Femtosecond laser pretreatment for brunescent cataracts allowed for a significant reduction in EPT compared with manual standard phacoemulsification techniques. Drs. Hatch, Talamo, and Dick are consultants to Abbott Medical Optics, Inc. Dr. Schultz has no financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  8. Learning curve in robotic rectal cancer surgery: current state of affairs.

    PubMed

    Jiménez-Rodríguez, Rosa M; Rubio-Dorado-Manzanares, Mercedes; Díaz-Pavón, José Manuel; Reyes-Díaz, M Luisa; Vazquez-Monchul, Jorge Manuel; Garcia-Cabrera, Ana M; Padillo, Javier; De la Portilla, Fernando

    2016-12-01

    Robotic-assisted rectal cancer surgery offers multiple advantages for surgeons, and it seems to yield the same clinical outcomes as regards the short-time follow-up of patients compared to conventional laparoscopy. This surgical approach emerges as a technique aiming at overcoming the limitations posed by rectal cancer and other surgical fields of difficult access, in order to obtain better outcomes and a shorter learning curve. A systematic review of the literature of robot-assisted rectal surgery was carried out according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement. The search was conducted in October 2015 in PubMed, MEDLINE and the Cochrane Central Register of Controlled Trials, for articles published in the last 10 years and pertaining the learning curve of robotic surgery for colorectal cancer. It consisted of the following key words: "rectal cancer/learning curve/robotic-assisted laparoscopic surgery". A total of 34 references were identified, but only 9 full texts specifically addressed the analysis of the learning curve in robot-assisted rectal cancer surgery, 7 were case series and 2 were non-randomised case-comparison series. Eight papers used the cumulative sum (CUSUM) method, and only one author divided the series into two groups to compare both. The mean number of cases for phase I of the learning curve was calculated to be 29.7 patients; phase II corresponds to a mean number 37.4 patients. The mean number of cases required for the surgeon to be classed as an expert in robotic surgery was calculated to be 39 patients. Robotic advantages could have an impact on learning curve for rectal cancer and lower the number of cases that are necessary for rectal resections.

  9. Biochemical changes related to hypoxia during cerebral aneurysm surgery: combined microdialysis and tissue oxygen monitoring: case report.

    PubMed

    Hutchinson, P J; Al-Rawi, P G; O'Connell, M T; Gupta, A K; Pickard, J D; Kirkpatrick, P J

    2000-01-01

    The objective of this study was to monitor brain metabolism on-line during aneurysm surgery, by combining the use of a multiparameter (brain tissue oxygen, brain carbon dioxide, pH, and temperature) sensor with microdialysis (extracellular glucose, lactate, pyruvate, and glutamate). The case illustrates the potential value of these techniques by demonstrating the effects of adverse physiological events on brain metabolism and the ability to assist in both intraoperative and postoperative decision-making. A 41-year-old woman presented with a World Federation of Neurological Surgeons Grade I subarachnoid hemorrhage. Angiography revealed a basilar artery aneurysm that was not amenable to coiling, so the aneurysm was clipped. Before the craniotomy was performed, a multiparameter sensor and a microdialysis catheter were inserted to monitor brain metabolism. During the operation, the brain oxygen level decreased, in relation to biochemical changes, including the reduction of extracellular glucose and pyruvate and the elevation of lactate and glutamate. These changes were reversible. However, when the craniotomy was closed, a second decrease in brain oxygen occurred in association with brain swelling, which immediately prompted a postoperative computed tomographic scan. The scan demonstrated acute hydrocephalus, requiring external ventricular drainage. The patient made a full recovery. The monitoring techniques influenced clinical decision-making in the treatment of this patient. On-line measurement of brain tissue gases and extracellular chemistry has the potential to assist in the perioperative and postoperative management of patients undergoing complex cerebrovascular surgery and to establish the effects of intervention on brain homeostasis.

  10. [End-of-life decisions and practices in critically ill patients in the cardiac intensive care unit. A nationwide survey].

    PubMed

    Schimmer, C; Hamouda, K; Oezkur, M; Sommer, S-P; Leistner, M; Leyh, R

    2016-03-01

    Ethical and medical criteria in the decision-making process of withholding or withdrawal of life support therapy in critically ill patients present a great challenge in intensive care medicine. The purpose of this work was to assess medical and ethical criteria that influence the decision-making process for changing the aim of therapy in critically ill cardiac surgery patients. A questionnaire was distributed to all German cardiac surgery centers (n = 79). All clinical directors, intensive care unit (ICU) consultants and ICU head nurses were asked to complete questionnaires (n = 237). In all, 86 of 237 (36.3 %) questionnaires were returned. Medical reasons which influence the decision-making process for changing the aim of therapy were cranial computed tomography (cCT) with poor prognosis (91.9 %), multi-organ failure (70.9 %), and failure of assist device therapy (69.8 %). Concerning ethical reasons, poor expected quality of life (48.8 %) and the presumed patient's wishes (40.7 %) were reported. There was a significant difference regarding the perception of the three different professional groups concerning medical and ethical criteria as well as the involvement in the decision-making process. In critically ill cardiac surgery patients, medical reasons which influence the decision-making process for changing the aim of therapy included cCT with poor prognosis, multi-organ failure, and failure of assist device therapy. Further studies are mandatory in order to be able to provide adequate answers to this difficult topic.

  11. Three-dimensional printing and computer navigation assisted hemipelvectomy for en bloc resection of osteochondroma

    PubMed Central

    Zhang, Yaqing; Wen, Lianjiang; Zhang, Jun; Yan, Guoliang; Zhou, Yue; Huang, Bo

    2017-01-01

    Abstract Rationale: Three-dimensional (3D) printed templates can be designed to match an individual's anatomy, allowing surgeons to refine preoperative planning. In addition, the use of computer navigation (NAV) is gaining popularity to improve surgical accuracy in the resection of pelvic tumors. However, its use in combination with 3D printing to assist complex pelvic tumor resection has not been reported. Patient concerns: A 36-year-old man presented with left-sided pelvic pain and a fast-growing mass. He also complained of a 3-month history of radiating pain and numbness in the lower left extremity. Diagnoses: A biopsy revealed an osteochondroma with malignant potential. This osteochondroma arises from the ilium and involves the sacrum and lower lumbar vertebrae. Interventions: Here, we describe a novel combined application of 3D printing and intraoperative NAV systems to guide hemipelvectomy for en-bloc resection of the osteochondroma. The 3D printed template is analyzed during surgical planning and guides the initial intraoperative bone work to improve surgical accuracy and efficiency, while a computer NAV system provides real-time imaging during the tumor removal to achieve adequate resection margins and minimize the likelihood of injury to adjacent critical structures. Outcomes: The tumor mass and the invaded spinal structures were removed en bloc. Lessons: The combined application of 3D printing and computer NAV may be useful for tumor targeting and safe osteotomies in pelvic tumor surgery. PMID:28328842

  12. Surgical criteria for femoroacetabular impingement syndrome: a scoping review.

    PubMed

    Peters, Scott; Laing, Alisha; Emerson, Courtney; Mutchler, Kelsey; Joyce, Thomas; Thorborg, Kristian; Hölmich, Per; Reiman, Michael

    2017-11-01

    The purpose of this review was to analyse and report criteria used for open and arthroscopic surgical treatment of femoroacetabular impingement syndrome (FAIS). A librarian-assisted computer search of Medline, CINAHL and Embase for studies related to criterion for FAIS surgery was used in this study. Inclusion criteria included studies with the primary purpose of surgery or surgical outcomes for treatment of FAIS with and without labral tear, and reporting criteria for FAIS surgery. Diagnostic imaging was a criterion for surgery in 92% of the included studies, with alpha angle the most frequently reported (68% of studies) criterion. Reporting of symptoms was a criterion for surgery in 75%, and special tests a criterion in 70% of studies. Range-of-motion limitations were only a required criterion in 30%, only 12% of studies required intra-articular injection and 44% of studies described previously failed treatment (non-surgical or physiotherapist-led rehabilitation) as a criterion for surgery. Only 56% of included studies utilised the combination of symptoms, clinical signs and diagnostic imaging combined for diagnosis of FAIS as suggested by the Warwick Agreement on FAIS meeting. Diagnostic imaging evidence of FAIS was the most commonly reported criterion for surgery. Only 56% of included studies utilised the combination of symptoms, clinical signs and diagnostic imaging for diagnosis of FAIS as suggested by the Warwick Agreement on FAIS meeting, and only 44% of studies had failed non-surgical treatment (and 18% a failed trial of physiotherapy) as a criterion for surgery. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  13. Three-dimensional simulation, surgical navigation and thoracoscopic lung resection

    PubMed Central

    Kanzaki, Masato; Kikkawa, Takuma; Sakamoto, Kei; Maeda, Hideyuki; Wachi, Naoko; Komine, Hiroshi; Oyama, Kunihiro; Murasugi, Masahide; Onuki, Takamasa

    2013-01-01

    This report describes a 3-dimensional (3-D) video-assisted thoracoscopic lung resection guided by a 3-D video navigation system having a patient-specific 3-D reconstructed pulmonary model obtained by preoperative simulation. A 78-year-old man was found to have a small solitary pulmonary nodule in the left upper lobe in chest computed tomography. By a virtual 3-D pulmonary model the tumor was found to be involved in two subsegments (S1 + 2c and S3a). Complete video-assisted thoracoscopic surgery bi-subsegmentectomy was selected in simulation and was performed with lymph node dissection. A 3-D digital vision system was used for 3-D thoracoscopic performance. Wearing 3-D glasses, the patient's actual reconstructed 3-D model on 3-D liquid-crystal displays was observed, and the 3-D intraoperative field and the picture of 3-D reconstructed pulmonary model were compared. PMID:24964426

  14. Use of robotics in colon and rectal surgery.

    PubMed

    Pucci, Michael J; Beekley, Alec C

    2013-03-01

    The pace of innovation in the field of surgery continues to accelerate. As new technologies are developed in combination with industry and clinicians, specialized patient care improves. In the field of colon and rectal surgery, robotic systems offer clinicians many alternative ways to care for patients. From having the ability to round remotely to improved visualization and dissection in the operating room, robotic assistance can greatly benefit clinical outcomes. Although the field of robotics in surgery is still in its infancy, many groups are actively investigating technologies that will assist clinicians in caring for their patients. As these technologies evolve, surgeons will continue to find new and innovative ways to utilize the systems for improved patient care and comfort.

  15. Robotic aortic surgery.

    PubMed

    Duran, Cassidy; Kashef, Elika; El-Sayed, Hosam F; Bismuth, Jean

    2011-01-01

    Surgical robotics was first utilized to facilitate neurosurgical biopsies in 1985, and it has since found application in orthopedics, urology, gynecology, and cardiothoracic, general, and vascular surgery. Surgical assistance systems provide intelligent, versatile tools that augment the physician's ability to treat patients by eliminating hand tremor and enabling dexterous operation inside the patient's body. Surgical robotics systems have enabled surgeons to treat otherwise untreatable conditions while also reducing morbidity and error rates, shortening operative times, reducing radiation exposure, and improving overall workflow. These capabilities have begun to be realized in two important realms of aortic vascular surgery, namely, flexible robotics for exclusion of complex aortic aneurysms using branched endografts, and robot-assisted laparoscopic aortic surgery for occlusive and aneurysmal disease.

  16. Technical and instrumental prerequisites for single-port laparoscopic solo surgery: State of art

    PubMed Central

    Kim, Say-June; Lee, Sang Chul

    2015-01-01

    With the aid of advanced surgical techniques and instruments, single-port laparoscopic surgery (SPLS) can be accomplished with just two surgical members: an operator and a camera assistant. Under these circumstances, the reasonable replacement of a human camera assistant by a mechanical camera holder has resulted in a new surgical procedure termed single-port solo surgery (SPSS). In SPSS, the fixation and coordinated movement of a camera held by mechanical devices provides fixed and stable operative images that are under the control of the operator. Therefore, SPSS primarily benefits from the provision of the operator’s eye-to-hand coordination. Because SPSS is an intuitive modification of SPLS, the indications for SPSS are the same as those for SPLS. Though SPSS necessitates more actions than the surgery with a human assistant, these difficulties seem to be easily overcome by the greater provision of static operative images and the need for less lens cleaning and repositioning of the camera. When the operation is expected to be difficult and demanding, the SPSS process could be assisted by the addition of another instrument holder besides the camera holder. PMID:25914453

  17. A Preliminary Report on the CO2 Laser for Lumbar Fusion: Safety, Efficacy and Technical Considerations.

    PubMed

    Villavicencio, Alan T; Burneikiene, Sigita; Babuska, Jason M; Nelson, Ewell L; Mason, Alexander; Rajpal, Sharad

    2015-04-01

    The purpose of this study was to evaluate potential technical advantages of the CO2 laser technology in mini-open transforaminal lumbar interbody fusion (TLIF) surgeries and report our preliminary clinical data on the safety and clinical outcomes. There is currently no literature discussing the recently redeveloped CO2 laser technology application for lumbar fusion. Safety and clinical outcomes were compared between two groups: 24 patients that underwent CO2 laser-assisted one-level TLIF surgeries and 30 patients that underwent standard one-level TLIF surgeries without the laser. There were no neural thermal injuries or other intraoperative laser-related complications encountered in this cohort of patients. At a mean follow-up of 17.4 months, significantly reduced lower back pain scores (P=0.013) were reported in the laser-assisted patient group compared to a standard fusion patient group. Lower extremity radicular pain intensity scores were similar in both groups. Laser-assisted TLIF surgeries showed a tendency (P = 0.07) of shorter operative times that was not statistically significant. Based on this preliminary clinical report, the safety of the CO2 laser device for lumbar fusion surgeries was assessed. There were no neural thermal injuries or other intraoperative laser-related complications encountered in this cohort of patients. Further investigation of CO2 laser-assisted lumbar fusion procedures is warranted in order to evaluate its effect on clinical outcomes.

  18. Randomized clinical trial of robot-assisted versus standard laparoscopic right colectomy.

    PubMed

    Park, J S; Choi, G-S; Park, S Y; Kim, H J; Ryuk, J P

    2012-09-01

    Robotic surgery was invented to overcome the demerits of laparoscopic technique. However, it is unclear whether robot-assisted colectomy (RAC) has significant clinical advantages over laparoscopically assisted colectomy (LAC) in treating colonic cancer. The aim of this study was to compare the surgical outcomes of RAC versus LAC for right-sided colonic cancer. Patients with right-sided colonic cancer were randomized to receive RAC or LAC. The primary outcome measure was length of hospital stay. Secondary outcomes were duration of operation, morbidity, postoperative pain, hospital costs and pathological quality of the specimen. Of 71 patients randomized, 70 (35 in each group) were included in the analysis. Hospital stay, surgical complications, postoperative pain score, resection margin clearance and number of lymph nodes harvested were similar in both groups. The duration of surgery was longer in the RAC group (195 versus 130 min; P < 0·001). No conversion to open surgery was needed in either group. Overall hospital costs were significantly higher for RAC (US $ 12,235 versus $ 10,320; P = 0·013); the higher costs were attributed primarily to the costs of surgery, including consumables. Robotic-assisted laparoscopic right colectomy was feasible but provided no benefit to justify the greater cost. NCT01042743 (http://www.clinicaltrials.gov). Copyright © 2012 British Journal of Surgery Society Ltd. Published by John Wiley & Sons, Ltd.

  19. Hip joint centre position estimation using a dual unscented Kalman filter for computer-assisted orthopaedic surgery.

    PubMed

    Beretta, Elisa; De Momi, Elena; Camomilla, Valentina; Cereatti, Andrea; Cappozzo, Aurelio; Ferrigno, Giancarlo

    2014-09-01

    In computer-assisted knee surgery, the accuracy of the localization of the femur centre of rotation relative to the hip-bone (hip joint centre) is affected by the unavoidable and untracked pelvic movements because only the femoral pose is acquired during passive pivoting manoeuvres. We present a dual unscented Kalman filter algorithm that allows the estimation of the hip joint centre also using as input the position of a pelvic reference point that can be acquired with a skin marker placed on the hip, without increasing the invasiveness of the surgical procedure. A comparative assessment of the algorithm was carried out using data provided by in vitro experiments mimicking in vivo surgical conditions. Soft tissue artefacts were simulated and superimposed onto the position of a pelvic landmark. Femoral pivoting made of a sequence of star-like quasi-planar movements followed by a circumduction was performed. The dual unscented Kalman filter method proved to be less sensitive to pelvic displacements, which were shown to be larger during the manoeuvres in which the femur was more adducted. Comparable accuracy between all the analysed methods resulted for hip joint centre displacements smaller than 1 mm (error: 2.2 ± [0.2; 0.3] mm, median ± [inter-quartile range 25%; inter-quartile range 75%]) and between 1 and 6 mm (error: 4.8 ± [0.5; 0.8] mm) during planar movements. When the hip joint centre displacement exceeded 6 mm, the dual unscented Kalman filter proved to be more accurate than the other methods by 30% during multi-planar movements (error: 5.2 ± [1.2; 1] mm). © IMechE 2014.

  20. Clinical, functional, and radiographic outcomes following total knee arthroplasty with patient-specific instrumentation, computer-assisted surgery, and manual instrumentation: a short-term follow-up study.

    PubMed

    Yaffe, Mark; Luo, Michael; Goyal, Nitin; Chan, Philip; Patel, Anay; Cayo, Max; Stulberg, S David

    2014-09-01

    The purpose of this study was to evaluate clinical, functional, and radiographic outcomes following total knee arthroplasty (TKA) performed with patient-specific instrumentation (PSI), computer-assisted surgery (CAS), and manual instruments at short-term follow-up. 122 TKAs were performed by a single surgeon: 42 with PSI, 38 with CAS, and 40 with manual instrumentation. Preoperative, 1-month, and 6-month clinical and functional outcomes were measured using the Knee Society scoring system (knee score, function score, range of motion, and pain score). Improvements in clinical and functional outcomes from the preoperative to postoperative period were analyzed. Preoperative and postoperative radiographs were measured to evaluate limb and component alignment. Preoperative, 1-month postoperative, and 6-month postoperative knee scores, function scores, range of motion, and pain scores were highest in the PSI group compared to CAS and manual instrumentation. At 6-month follow-up, PSI TKA was associated with a statistically significant improvement in functional score when compared to manual TKA. Otherwise, there were no statistically significant differences in improvements among PSI, CAS, and manual TKA groups. The higher preoperative scores in the PSI group limits the ability to draw definitive conclusions from the raw postoperative scores, but analyzing the changes in scores revealed that PSI was associated with a statistically significant improvement in Knee Society Functional score at 6-month post-TKA as compared to CAS or manual TKA. This may be attributable to improvements in component rotation and positioning, improved component size accuracy, or other factors that are not discernible on plain radiograph.

  1. Towards cybernetic surgery: robotic and augmented reality-assisted liver segmentectomy.

    PubMed

    Pessaux, Patrick; Diana, Michele; Soler, Luc; Piardi, Tullio; Mutter, Didier; Marescaux, Jacques

    2015-04-01

    Augmented reality (AR) in surgery consists in the fusion of synthetic computer-generated images (3D virtual model) obtained from medical imaging preoperative workup and real-time patient images in order to visualize unapparent anatomical details. The 3D model could be used for a preoperative planning of the procedure. The potential of AR navigation as a tool to improve safety of the surgical dissection is outlined for robotic hepatectomy. Three patients underwent a fully robotic and AR-assisted hepatic segmentectomy. The 3D virtual anatomical model was obtained using a thoracoabdominal CT scan with a customary software (VR-RENDER®, IRCAD). The model was then processed using a VR-RENDER® plug-in application, the Virtual Surgical Planning (VSP®, IRCAD), to delineate surgical resection planes including the elective ligature of vascular structures. Deformations associated with pneumoperitoneum were also simulated. The virtual model was superimposed to the operative field. A computer scientist manually registered virtual and real images using a video mixer (MX 70; Panasonic, Secaucus, NJ) in real time. Two totally robotic AR segmentectomy V and one segmentectomy VI were performed. AR allowed for the precise and safe recognition of all major vascular structures during the procedure. Total time required to obtain AR was 8 min (range 6-10 min). Each registration (alignment of the vascular anatomy) required a few seconds. Hepatic pedicle clamping was never performed. At the end of the procedure, the remnant liver was correctly vascularized. Resection margins were negative in all cases. The postoperative period was uneventful without perioperative transfusion. AR is a valuable navigation tool which may enhance the ability to achieve safe surgical resection during robotic hepatectomy.

  2. Three-dimensional-printed cardiac prototypes aid surgical decision-making and preoperative planning in selected cases of complex congenital heart diseases: Early experience and proof of concept in a resource-limited environment.

    PubMed

    Kappanayil, Mahesh; Koneti, Nageshwara Rao; Kannan, Rajesh R; Kottayil, Brijesh P; Kumar, Krishna

    2017-01-01

    Three-dimensional. (3D) printing is an innovative manufacturing process that allows computer-assisted conversion of 3D imaging data into physical "printouts" Healthcare applications are currently in evolution. The objective of this study was to explore the feasibility and impact of using patient-specific 3D-printed cardiac prototypes derived from high-resolution medical imaging data (cardiac magnetic resonance imaging/computed tomography [MRI/CT]) on surgical decision-making and preoperative planning in selected cases of complex congenital heart diseases (CHDs). Five patients with complex CHD with previously unresolved management decisions were chosen. These included two patients with complex double-outlet right ventricle, two patients with criss-cross atrioventricular connections, and one patient with congenitally corrected transposition of great arteries with pulmonary atresia. Cardiac MRI was done for all patients, cardiac CT for one; specific surgical challenges were identified. Volumetric data were used to generate patient-specific 3D models. All cases were reviewed along with their 3D models, and the impact on surgical decision-making and preoperative planning was assessed. Accurate life-sized 3D cardiac prototypes were successfully created for all patients. The models enabled radically improved 3D understanding of anatomy, identification of specific technical challenges, and precise surgical planning. Augmentation of existing clinical and imaging data by 3D prototypes allowed successful execution of complex surgeries for all five patients, in accordance with the preoperative planning. 3D-printed cardiac prototypes can radically assist decision-making, planning, and safe execution of complex congenital heart surgery by improving understanding of 3D anatomy and allowing anticipation of technical challenges.

  3. Retention of robot-assisted surgical skills in urological surgeons acquired using Mimic dV-Trainer.

    PubMed

    Teishima, Jun; Hattori, Minoru; Inoue, Shogo; Ikeda, Kenichiro; Hieda, Keisuke; Ohara, Shinya; Egi, Hiroyuki; Ohdan, Hideki; Matsubara, Akio

    2014-07-01

    We assess the retention of robot-assisted surgical skills among urologic surgeons. The robot-assisted surgery skills of 20 urologic surgeons were assessed using a Mimic dV-Trainer program (Mimic Technologies, Inc., Seattle, WA) consisting of 6 tasks. These 20 surgeons had no previous experience either using the Mimic dV-Trainer or acting as the main surgeon in robot-assisted surgery. The surgeons completed the program 4 times in a row; after 1 year, they completed it again for a fifth time. Performance scores were recorded using the Mimic dV-Trainer's built-in algorithm. For all 6 tasks, there were significant improvements to the scores in the fourth trials compared with those in the first trials. The scores in the fifth trials did not significantly decline compared with those in the fourth trials. There was no significant difference between the fifth trial scores of surgeons with laparoscopic surgery skills/experience and those without. Our results indicate that fundamental robot-assisted surgical skills can be retained in the long-term after they are acquired.

  4. Hybrid procedure for total laryngectomy with a flexible robot-assisted surgical system.

    PubMed

    Schuler, Patrick J; Hoffmann, Thomas K; Veit, Johannes A; Rotter, Nicole; Friedrich, Daniel T; Greve, Jens; Scheithauer, Marc O

    2017-06-01

    Total laryngectomy is a standard procedure in head-and-neck surgery for the treatment of cancer patients. Recent clinical experiences have indicated a clinical benefit for patients undergoing transoral robot-assisted total laryngectomy (TORS-TL) with commercially available systems. Here, a new hybrid procedure for total laryngectomy is presented. TORS-TL was performed in human cadavers (n = 3) using a transoral-transcervical hybrid procedure. The transoral approach was performed with a robotic flexible robot-assisted surgical system (Flex®) and compatible flexible instruments. Transoral access and visualization of anatomical landmarks were studied in detail. Total laryngectomy is feasible with a combined transoral-transcervical approach using the flexible robot-assisted surgical system. Transoral visualization of all anatomical structures is sufficient. The flexible design of the robot is advantageous for transoral surgery of the laryngeal structures. Transoral robot assisted surgery has the potential to reduce morbidity, hospital time and fistula rates in a selected group of patients. Initial clinical studies and further development of supplemental tools are in progress. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  5. Robotics in urological surgery: evolution, current status and future perspectives.

    PubMed

    Sivaraman, A; Sanchez-Salas, R; Prapotnich, D; Barret, E; Mombet, A; Cathala, N; Rozet, F; Galiano, M; Cathelineau, X

    2015-09-01

    Robotic surgery is rapidly evolving and has become an essential part of surgical practice in several parts of the world. Robotic technology will expand globally and most of the surgeons around the world will have access to surgical robots in the future. It is essential that we are updated about the outcomes of robot assisted surgeries which will allow everyone to develop an unbiased opinion on the clinical utility of this innovation. In this review we aim to present the evolution, objective evaluation of clinical outcomes and future perspectives of robot assisted urologic surgeries. A systematic literature review of clinical outcomes of robotic urological surgeries was made in the PUBMED. Randomized control trials, cohort studies and review articles were included. Moreover, a detailed search in the web based search engine was made to acquire information on evolution and evolving technologies in robotics. The present evidence suggests that the clinical outcomes of the robot assisted urologic surgeries are comparable to the conventional open surgical and laparoscopic results and are associated with fewer complications. However, long term results are not available for all the common robotic urologic surgeries. There are plenty of novel developments in robotics to be available for clinical use in the future. Robotic urologic surgery will continue to evolve in the future. We should continue to critically analyze whether the advances in technology and the higher cost eventually translates to improved overall surgical performance and outcomes. Copyright © 2014 AEU. Publicado por Elsevier España, S.L.U. All rights reserved.

  6. Survey on Robot-Assisted Surgical Techniques Utilization in US Pediatric Surgery Fellowships.

    PubMed

    Maizlin, Ilan I; Shroyer, Michelle C; Yu, David C; Martin, Colin A; Chen, Mike K; Russell, Robert T

    2017-02-01

    Robotic technology has transformed both practice and education in many adult surgical specialties; no standardized training guidelines in pediatric surgery currently exist. The purpose of our study was to assess the prevalence of robotic procedures and extent of robotic surgery education in US pediatric surgery fellowships. A deidentified survey measured utilization of the robot, perception on the utility of the robot, and its incorporation in training among the program directors of Accreditation Council for Graduate Medical Education (ACGME) pediatric surgery fellowships in the United States. Forty-one of the 47 fellowship programs (87%) responded to the survey. While 67% of respondents indicated the presence of a robot in their facility, only 26% reported its utilizing in their surgical practice. Among programs not utilizing the robot, most common reasons provided were lack of clear supportive evidence, increased intraoperative time, and incompatibility of instrument size to pediatric patients. While 58% of program directors believe that there is a future role for robotic surgery in children, only 18% indicated that robotic training should play a part in pediatric surgery education. Consequently, while over 66% of survey respondents received training in robot-assisted surgical technique, only 29% of fellows receive robot-assisted training during their fellowship. A majority of fellowships have access to a robot, but few utilize the technology in their current practice or as part of training. Further investigation is required into both the technology's potential benefits in the pediatric population and its role in pediatric surgery training.

  7. Novel use of an ultrasonic bone-cutting device for endoscopic-assisted craniosynostosis surgery.

    PubMed

    Chaichana, Kaisorn L; Jallo, George I; Dorafshar, Amir H; Ahn, Edward S

    2013-07-01

    Endoscopic-assisted craniosynostosis surgery is associated with less blood loss and shorter operative times as compared to open surgery. However, in infants who have low circulating blood volumes, the endoscopic approach is still associated with significant blood loss. A major source of blood loss is the bone that is cut during surgery. We discuss the novel use of an ultrasonic bone-cutting device for craniosynostosis surgery, which decreases bone bleeding. This device, which has primarily only been used for spine and skull base surgery, may help reduce blood loss in these infants. All patients with single suture craniosynostosis who were operated on with the use of an ultrasonic bone-cutting device were identified. The information retrospectively recorded from patient charts included patient age, suture involved, blood loss, operative times, complications, preoperative hemoglobin, postoperative hemoglobin, length of hospital stay, and follow-up times. Thirteen patients (12 males, 1 female) underwent surgery with an ultrasonic bone-cutting device during the reviewed period. The average age (±standard deviation) of the patients was 11.8 (±1.6) weeks. Four patients had metopic synostosis and nine patients had sagittal synostosis. The average surgery time was 84 (±13) min. The median (interquartile range) blood loss was 20 (10-70) cc. No patients required blood transfusions. Three patients had dural tears. We demonstrate the novel use of an ultrasonic bone-cutting device for endoscopic-assisted craniosynostosis surgery. This device limited blood loss while maintaining short operative times for infants with low circulating blood volumes.

  8. Emerging Applications of Bedside 3D Printing in Plastic Surgery

    PubMed Central

    Chae, Michael P.; Rozen, Warren M.; McMenamin, Paul G.; Findlay, Michael W.; Spychal, Robert T.; Hunter-Smith, David J.

    2015-01-01

    Modern imaging techniques are an essential component of preoperative planning in plastic and reconstructive surgery. However, conventional modalities, including three-dimensional (3D) reconstructions, are limited by their representation on 2D workstations. 3D printing, also known as rapid prototyping or additive manufacturing, was once the province of industry to fabricate models from a computer-aided design (CAD) in a layer-by-layer manner. The early adopters in clinical practice have embraced the medical imaging-guided 3D-printed biomodels for their ability to provide tactile feedback and a superior appreciation of visuospatial relationship between anatomical structures. With increasing accessibility, investigators are able to convert standard imaging data into a CAD file using various 3D reconstruction softwares and ultimately fabricate 3D models using 3D printing techniques, such as stereolithography, multijet modeling, selective laser sintering, binder jet technique, and fused deposition modeling. However, many clinicians have questioned whether the cost-to-benefit ratio justifies its ongoing use. The cost and size of 3D printers have rapidly decreased over the past decade in parallel with the expiration of key 3D printing patents. Significant improvements in clinical imaging and user-friendly 3D software have permitted computer-aided 3D modeling of anatomical structures and implants without outsourcing in many cases. These developments offer immense potential for the application of 3D printing at the bedside for a variety of clinical applications. In this review, existing uses of 3D printing in plastic surgery practice spanning the spectrum from templates for facial transplantation surgery through to the formation of bespoke craniofacial implants to optimize post-operative esthetics are described. Furthermore, we discuss the potential of 3D printing to become an essential office-based tool in plastic surgery to assist in preoperative planning, developing intraoperative guidance tools, teaching patients and surgical trainees, and producing patient-specific prosthetics in everyday surgical practice. PMID:26137465

  9. Emerging Applications of Bedside 3D Printing in Plastic Surgery.

    PubMed

    Chae, Michael P; Rozen, Warren M; McMenamin, Paul G; Findlay, Michael W; Spychal, Robert T; Hunter-Smith, David J

    2015-01-01

    Modern imaging techniques are an essential component of preoperative planning in plastic and reconstructive surgery. However, conventional modalities, including three-dimensional (3D) reconstructions, are limited by their representation on 2D workstations. 3D printing, also known as rapid prototyping or additive manufacturing, was once the province of industry to fabricate models from a computer-aided design (CAD) in a layer-by-layer manner. The early adopters in clinical practice have embraced the medical imaging-guided 3D-printed biomodels for their ability to provide tactile feedback and a superior appreciation of visuospatial relationship between anatomical structures. With increasing accessibility, investigators are able to convert standard imaging data into a CAD file using various 3D reconstruction softwares and ultimately fabricate 3D models using 3D printing techniques, such as stereolithography, multijet modeling, selective laser sintering, binder jet technique, and fused deposition modeling. However, many clinicians have questioned whether the cost-to-benefit ratio justifies its ongoing use. The cost and size of 3D printers have rapidly decreased over the past decade in parallel with the expiration of key 3D printing patents. Significant improvements in clinical imaging and user-friendly 3D software have permitted computer-aided 3D modeling of anatomical structures and implants without outsourcing in many cases. These developments offer immense potential for the application of 3D printing at the bedside for a variety of clinical applications. In this review, existing uses of 3D printing in plastic surgery practice spanning the spectrum from templates for facial transplantation surgery through to the formation of bespoke craniofacial implants to optimize post-operative esthetics are described. Furthermore, we discuss the potential of 3D printing to become an essential office-based tool in plastic surgery to assist in preoperative planning, developing intraoperative guidance tools, teaching patients and surgical trainees, and producing patient-specific prosthetics in everyday surgical practice.

  10. Tele-surgery simulation with a patient organ model for robotic surgery training.

    PubMed

    Suzuki, S; Suzuki, N; Hattori, A; Hayashibe, M; Konishi, K; Kakeji, Y; Hashizume, M

    2005-12-01

    Robotic systems are increasingly being incorporated into general laparoscopic and thoracoscopic surgery to perform procedures such as cholecystectomy and prostatectomy. Robotic assisted surgery allows the surgeon to conduct minimally invasive surgery with increased accuracy and with potential benefits for patients. However, current robotic systems have their limitations. These include the narrow operative field of view, which can make instrument manipulation difficult. Current robotic applications are also tailored to specific surgical procedures. For these reasons, there is an increasing demand on surgeons to master the skills of instrument manipulation and their surgical application within a controlled environment. This study describes the development of a surgical simulator for training and mastering procedures performed with the da Vinci surgical system. The development of a tele-surgery simulator and the construction of a training center are also described, which will enable surgeons to simulate surgery from or in remote places, to collaborate over long distances, and for off-site expert assistance. Copyright 2005 John Wiley & Sons, Ltd.

  11. Laser-assisted cataract surgery versus standard ultrasound phacoemulsification cataract surgery.

    PubMed

    Day, Alexander C; Gore, Daniel M; Bunce, Catey; Evans, Jennifer R

    2016-07-08

    Cataract is the leading cause of blindness in the world, and cataract surgery is one of the most commonly performed operations in the Western world. Preferred surgical techniques have changed dramatically over the past half century with associated improvements in outcomes and safety. Femtosecond laser platforms that can accurately and reproducibly perform key steps in cataract surgery, including corneal incisions, capsulotomy and lens fragmentation, are now available. The potential advantages of laser-assisted surgery are broad, and include greater safety and better visual outcomes through greater precision and reproducibility. To compare the effectiveness of laser-assisted cataract surgery with standard ultrasound phacoemulsification cataract surgery by gathering evidence on safety from randomised controlled trials (RCTs). We searched CENTRAL (which contains the Cochrane Eyes and Vision Trials Register) (2016, Issue 4), Ovid MEDLINE, Ovid MEDLINE In-Process and Other Non-Indexed Citations, Ovid MEDLINE Daily, Ovid OLDMEDLINE (January 1946 to May 2016), EMBASE (January 1980 to May 2016), Latin American and Caribbean Health Sciences Literature Database (LILACS) (January 1982 to May 2016), the ISRCTN registry (www.isrctn.com/editAdvancedSearch), ClinicalTrials.gov (www.clinicaltrials.gov), the World Health Organization (WHO) International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en) and the U.S. Food and Drugs Administration (FDA) website (www.fda.gov). We did not use any date or language restrictions in the electronic searches for trials. We last searched the electronic databases on 10 May 2016. We included randomised controlled trials where laser-assisted cataract surgery was compared to standard ultrasound phacoemulsification cataract surgery. We graded the certainty of the evidence using GRADE. Two review authors independently screened the search results, assessed risk of bias and extracted data using the standard methodological procedures expected by Cochrane. The primary outcome for this review was intraoperative complications in the operated eye, namely anterior capsule and posterior capsule tears. The secondary outcomes were visual acuity (corrected distance visual acuity (CDVA) and uncorrected distance visual acuity (UDVA)), refractive outcomes, quality of vision (as measured by any validated visual function score), postoperative complications and cost-effectiveness. We included 16 RCTs conducted in Germary, Hungary, Italy, India, China and Brazil that enrolled a total of 1638 eyes of 1245 adult participants. Overall, the studies were at unclear or high risk of bias. In 11 of the studies the authors reported financial links with the manufacturer of the laser platform evaluated in their studies. Five of the studies were within-person (paired-eye) studies with one eye allocated to one procedure and the other eye allocated to the other procedure. These studies were reported ignoring the paired nature of the data.The number of anterior capsule and posterior capsule tears reported in the included studies for both laser cataract surgery and manual phacoemulsification cataract surgery were low. There were four anterior capsule tears and one posterior capsule tear in 1076 eyes reported in 10 studies (2 anterior capsule tears in laser arms, 2 anterior capsule tears and 1 posterior capsule tear in standard phacoemulsification arms). We are very uncertain as to the effect of laser-assisted surgery compared to standard phacoemulsification surgery with respect to these two outcomes. For postoperative cystoid macular oedema and elevated postoperative intraocular pressures, again the evidence was inconclusive (odds ratio (OR) 0.58, 95% confidence interval (CI) 0.20 to 1.68; 957 eyes, 9 studies, low certainty evidence; and OR 0.57, 95% CI 0.11 to 2.86; 903 eyes, 8 studies, low certainty evidence).We found little evidence of any important difference in postoperative visual acuity between laser-assisted and standard phacoemulsification arms. There was a small advantage for laser-assisted cataract surgery at six months in CDVA. However, the mean difference (MD) was -0.03 logMAR (95% CI -0.05 to -0.00; 224 eyes, 3 studies, low certainty evidence) which is equivalent to 1.5 logMAR letters and is therefore, clinically insignificant. No studies reported patient-reported outcome measures such as visual function.There were no data reported on costs or resource use but three studies reported the time taken to do the surgery. There was little evidence of any major difference between the two procedures in this respect (MD 0.1 minutes, 95% CI -0.02 to 0.21; 274 eyes, low certainty evidence). The evidence from the 16 randomised controlled trials RCTs included in this review could not determine the equivalence or superiority of laser-assisted cataract surgery compared to standard manual phacoemulsification for our chosen outcomes due to the low to very low certainty of the evidence available from these studies. As complications occur rarely, large, adequately powered, well designed, independent RCTs comparing the safety and efficacy of laser-assisted cataract surgery with standard phacoemulsification cataract surgery are needed. Standardised reporting of complications and visual and refractive outcomes for cataract surgery would facilitate future synthesis. Data on patient-reported outcomes and cost-effectiveness are needed. Paired-eye studies should be analysed and reported appropriately.

  12. Virtual Surgical Planning in Precise Maxillary Reconstruction With Vascularized Fibular Graft After Tumor Ablation.

    PubMed

    Wang, You-Yuan; Fan, Song; Zhang, Han-Qing; Lin, Zhao-Yu; Ye, Jian-Tao; Li, Jin-Song

    2016-06-01

    Reconstruction of maxillary and midfacial defects due to tumor ablation is challenging to conventional operation. The purposes of this study are to evaluate the precise 3-dimensional position of the fibular flap in reconstruction of maxillary defects assisted by virtual surgical planning and to assess the postoperative outcomes compared with conventional surgery. We retrospectively reviewed 18 consecutive patients who underwent maxillary reconstruction with a vascularized fibular flap assisted by virtual surgical planning after maxillary or midfacial tumor ablation. Conventional surgery was performed in another 15 patients. Proplan CMF surgical planning (Materialise, Leuven, Belgium) was performed preoperatively in the virtual planning group. Fibular flaps were harvested and underwent osteotomy assisted by prefabricated cutting guides, and the maxilla and midface were resected and reconstructed assisted by the prefabricated cutting guides and templates in the virtual planning group. The operative time and fibular flap positions were evaluated in the 2 groups. Postoperative fibular positions of the maxillary reconstruction were compared with virtual plans in the virtual planning group. The postoperative facial appearance and occlusal function were assessed. The operations were performed successfully without complications. The ischemia time and total operative time were shorter in the virtual planning group than those in the conventional surgery group (P < .05). High precision of the cutting guides and templates was found on both the fibula and maxilla in the virtual planning group. The positions of the fibular flaps, including the vertical and horizontal positions, were more accurate in the virtual planning group than those in the conventional surgery group (P < .05). Bone-to-bone contact between the maxilla and fibular segments was more precise in the virtual planning group (P < .05). Postoperative computed tomography scans showed excellent contour of the fibular flap segments in accordance with the virtual plans in the virtual planning group. All patients were alive with no evidence of disease. Functional mandibular range of motion, good occlusion, and an ideal facial appearance were observed in the virtual planning group. Virtual surgical planning appears to achieve precise maxillary reconstruction with a vascularized fibular flap after tumor ablation, as well as an ideal facial appearance and function after dental rehabilitation. The use of prefabricated cutting guides and plates eases fibular flap molding and placement, minimizes operating time, and improves clinical outcomes. Copyright © 2016 The American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  13. Methodological approaches of health technology assessment.

    PubMed

    Goodman, C S; Ahn, R

    1999-12-01

    In this era of evolving health care systems throughout the world, technology remains the substance of health care. Medical informatics comprises a growing contribution to the technologies used in the delivery and management of health care. Diverse, evolving technologies include artificial neural networks, computer-assisted surgery, computer-based patient records, hospital information systems, and more. Decision-makers increasingly demand well-founded information to determine whether or how to develop these technologies, allow them on the market, acquire them, use them, pay for their use, and more. The development and wider use of health technology assessment (HTA) reflects this demand. While HTA offers systematic, well-founded approaches for determining the value of medical informatics technologies, HTA must continue to adapt and refine its methods in response to these evolving technologies. This paper provides a basic overview of HTA principles and methods.

  14. Diagnosis and management of solitary pulmonary nodules.

    PubMed

    Jeong, Yeon Joo; Lee, Kyung Soo; Kwon, O Jung

    2008-12-01

    The advent of computed tomography (CT) screening with or without the help of computer-aided detection systems has increased the detection rate of solitary pulmonary nodules (SPNs), including that of early peripheral lung cancer. Helical dynamic (HD)CT, providing the information on morphologic and hemodynamic characteristics with high specificity and reasonably high accuracy, can be used for the initial assessment of SPNs. (18)F-fluorodeoxyglucose PET/CT is more sensitive at detecting malignancy than HDCT. Therefore, PET/CT may be selectively performed to characterize SPNs when HDCT gives an inconclusive diagnosis. Serial volume measurements are currently the most reliable methods for the tissue characterization of subcentimeter nodules. When malignant nodule is highly suspected for subcentimeter nodules, video-assisted thoracoscopic surgery nodule removal after nodule localization using the pulmonary nodule-marker system may be performed for diagnosis and treatment.

  15. Strategies to optimize the performance of Robotic-assisted ­laparoscopic hysterectomy

    PubMed Central

    Lambrou, N.; Diaz, R.E.; Hinoul, P.; Parris, D.; Shoemaker, K.; Yoo, A.; Schwiers, M.

    2014-01-01

    A hybrid technique of robot-assisted, laparoscopic hysterectomy using the ENSEAL® Tissue Sealing Device is described in a retrospective, consecutive, observational case series. Over a 45 month period, 590 robot-assisted total laparoscopic hysterectomies +/- oophorectomy for benign and malignant indications were performed by a single surgeon with a bedside assistant at a tertiary healthcare center. Patient demographics, indications for surgery, comorbidities, primary and secondary surgical procedures, total operative and surgical time, estimated blood loss (EBL), length of stay (LOS), complications, transfusions and subsequent readmissions were analyzed. The overall complication rate was 5.9% with 35 patients experiencing 69 complications. Mean (SD) surgery time, operating room (OR) time, EBL, and LOS for the entire cohort were 75.5 (39.42) minutes, 123.8 (41.15) minutes, 83.1 (71.29) millilitres, and 1.2 (0.93) days, respectively. Mean surgery time in the first year (2009) was 91.6 minutes, which declined significantly each year by 18.0, 19.0, and 24.3 minutes, respectively. EBL and LOS did not vary ­significantly across the entire series. Using the cumulative sum method, an optimization curve for surgery time was evaluated, with three distinct optimization phases observed. In summary, the use of an advanced laparoscopic tissue-sealing device by a bedside surgical assistant provided an improved operative efficiency and reliable vessel sealing during robotic hysterectomy. PMID:25374656

  16. In-hospital mortality and morbidity after robotic coronary artery surgery.

    PubMed

    Cavallaro, Paul; Rhee, Amanda J; Chiang, Yuting; Itagaki, Shinobu; Seigerman, Matthew; Chikwe, Joanna

    2015-02-01

    The objective of this study was to assess the impact of robotic approaches on outcomes of coronary bypass surgery. Retrospective national database analysis. United States hospitals. A weighted sample of 484,128 patients undergoing isolated coronary artery surgery identified from the Nationwide Inpatient Sample from 2008 through 2010. Robotically assisted coronary artery bypass surgery versus conventional bypass surgery. Robotic approaches were used in 2,582 patients (0.4%). Patients undergoing robotic surgery were less likely to be female (odds ratio [OR] 0.71, 95% confidence interval [CI] 0.57-0.87), present with acute myocardial infarction (OR 0.53, 95% CI 0.38-0.73), or have cerebrovascular disease (OR 0.41, 95% CI 0.23-0.71) compared to patients undergoing conventional surgery. In 59% of robotic cases, a single bypass was performed, and 2 bypasses were performed in 25% of cases. After adjusting for comorbidity, reduced postoperative stroke (0.0% v 1.5%, p = 0.045) and transfusion (13.5% v 24.4%, p = 0.001) rates were observed in patients who underwent robotic single-bypass surgery compared to conventional surgery. In patients undergoing multiple bypass grafts, higher mortality (1.1% v 0.5%), and cardiovascular complications (12.2% v 10.6%) were observed when robotic assistance was used, but the differences were not statistically significant (p = 0.5). The mean number of robotic cases carried out annually at institutions sampled was 6. Robotic assistance is associated with lower rates of postoperative complications in highly selected patients undergoing single coronary artery bypass surgery, but the benefits of this approach are reduced in patients who require multiple coronary artery bypass grafts. Copyright © 2014 Elsevier Inc. All rights reserved.

  17. Macroeconomic landscape of refractive surgery in the United States.

    PubMed

    Corcoran, Kevin J

    2015-07-01

    This review examines the economic history of refractive surgery and the decline of laser-assisted in-situ keratomileusis (LASIK) in the USA, and the emergence of refractive cataract surgery as an area of growth. Since it peaked in 2007 at 1.4 million procedures per year, LASIK has declined 50% in the USA, whereas refractive cataract surgery, including presbyopia-correcting intraocular lenses (IOLs), astigmatism-correcting IOLs, and femtosecond laser-assisted cataract surgery, has grown to 350 000 procedures per year, beginning in 2003. Patients are price-sensitive and responsive to publicity (good or bad) about refractive surgery and refractive cataract surgery. LASIK's decline has been partially offset by the emergence of refractive cataract surgery. About 11% of all cataract surgery in the USA involves presbyopia-correcting IOLs, astigmatism-correcting IOLs, or a femtosecond laser. From the surgeon's perspective, there are high barriers to entry into the marketplace for refractive surgery and refractive cataract surgery due to the high capital cost of excimer and femtosecond lasers, the high skill level required to deliver spectacular results to demanding patients who pay out of pocket, and the necessity to perform a high volume of surgeries to satisfy both of these requirements. Probably, less than 7% of US cataract surgeons can readily meet all of these requirements.

  18. Clinical outcomes in endometrial cancer care when the standard of care shifts from open surgery to robotics.

    PubMed

    Mok, Zhun Wei; Yong, Eu Leong; Low, Jeffrey Jen Hui; Ng, Joseph Soon Yau

    2012-06-01

    In Singapore, the standard of care for endometrial cancer staging remains laparotomy. Since the introduction of gynecologic robotic surgery, there have been more data comparing robotic surgery to laparoscopy in the management of endometrial cancer. This study reviewed clinical outcomes in endometrial cancer in a program that moved from laparotomy to robotic surgery. A retrospective review was performed on 124 consecutive endometrial cancer patients. Preoperative data and postoperative outcomes of 34 patients undergoing robotic surgical staging were compared with 90 patients who underwent open endometrial cancer staging during the same period and in the year before the introduction of robotics. There were no significant differences in the mean age, body mass index, rates of diabetes, hypertension, previous surgery, parity, medical conditions, size of specimens, histologic type, or stage of cancer between the robotic and the open surgery groups. The first 20 robotic-assisted cases had a mean (SD) operative time of 196 (60) minutes, and the next 14 cases had a mean time of 124 (64) minutes comparable to that for open surgery. The mean number of lymph nodes retrieved during robot-assisted staging was smaller than open laparotomy in the first 20 cases but not significantly different for the subsequent 14 cases. Robot-assisted surgery was associated with lower intraoperative blood loss (110 [24] vs 250 [83] mL, P < 0.05), a lower rate of postoperative complications (8.8% vs 26.8%, P = 0.032), a lower wound complication rate (0% vs 9.9%, P = 0.044), a decreased requirement for postoperative parenteral analgesia (5.9% vs 51.1, P < 0.001), and shorter length of hospitalization (2.0 [1.1] vs 6.0 [4.5] days, P < 0.001) compared to patients in the open laparotomy group. Our series shows that outcomes traditionally associated with laparoscopic endometrial cancer staging are achievable by laparoscopy-naive gynecologic cancer surgeons moving from laparotomy to robot-assisted endometrial cancer staging after a relatively small number of cases.

  19. Robotic hysterectomy strategies in the morbidly obese patient.

    PubMed

    Almeida, Oscar D

    2013-01-01

    The purpose of this study was to present strategies for performing computer-enhanced telesurgery in the morbidly obese patient. This was a prospective, institutional review board-approved, descriptive feasibility study (Canadian Task Force classification II-2) conducted at a university-affiliated hospital. Twelve class III morbidly obese women with a body mass index of 40 kg/m(2) or greater were selected to undergo robotic-assisted total laparoscopic hysterectomy. Robotic-assisted total laparoscopic hysterectomy, classified as type IVE, with complete detachment of the cardinal-uterosacral ligament complex, unilateral or bilateral, with entry into the vagina was performed. The median estimated blood loss was 146.3 mL (range, 15-550 mL), the mean length of stay in the hospital was 25.3 hours (range, 23- 48 hours), and the complication rate was 0%. The rate of conversion to laparotomy was 8%. The median surgical time was 109.6 minutes (range, 99 -145 minutes). Robotic-assisted total laparoscopic hysterectomy can be a safe and effective method of performing hysterectomies in select morbidly obese patients, allowing them the opportunity to undergo minimally invasive surgery without increased perioperative complications.

  20. [Scientometrics and bibliometrics of biomedical engineering periodicals and papers].

    PubMed

    Zhao, Ping; Xu, Ping; Li, Bingyan; Wang, Zhengrong

    2003-09-01

    This investigation was made to reveal the current status, research trend and research level of biomedical engineering in Chinese mainland by means of scientometrics and to assess the quality of the four domestic publications by bibliometrics. We identified all articles of four related publications by searching Chinese and foreign databases from 1997 to 2001. All articles collected or cited by these databases were searched and statistically analyzed for finding out the relevant distributions, including databases, years, authors, institutions, subject headings and subheadings. The source of sustentation funds and the related articles were analyzed too. The results showed that two journals were cited by two foreign databases and five Chinese databases simultaneously. The output of Journal of Biomedical Engineering was the highest. Its quantity of original papers cited by EI, CA and the totality of papers sponsored by funds were higher than those of the others, but the quantity and percentage per year of biomedical articles cited by EI were decreased in all. Inland core authors and institutions had come into being in the field of biomedical engineering. Their research topics were mainly concentrated on ten subject headings which included biocompatible materials, computer-assisted signal processing, electrocardiography, computer-assisted image processing, biomechanics, algorithms, electroencephalography, automatic data processing, mechanical stress, hemodynamics, mathematical computing, microcomputers, theoretical models, etc. The main subheadings were concentrated on instrumentation, physiopathology, diagnosis, therapy, ultrasonography, physiology, analysis, surgery, pathology, method, etc.

Top