Sample records for surgical clipping technique

  1. Harmonic Scalpel versus electrocautery and surgical clips in head and neck free-flap harvesting.

    PubMed

    Dean, Nichole R; Rosenthal, Eben L; Morgan, Bruce A; Magnuson, J Scott; Carroll, William R

    2014-06-01

    We sought to determine the safety and utility of Harmonic Scalpel-assisted free-flap harvesting as an alternative to a combined electrocautery and surgical clip technique. The medical records of 103 patients undergoing radial forearm free-flap reconstruction (105 free flaps) for head and neck surgical defects between 2006 and 2008 were reviewed. The use of bipolar electrocautery and surgical clips for division of small perforating vessels (n = 53) was compared to ultrasonic energy (Harmonic Scalpel; Ethicon Endo-Surgery, Inc., Cincinnati, Ohio) (n = 52) free-tissue harvesting techniques. Flap-harvesting time was reduced with the use of the Harmonic Scalpel when compared with electrocautery and surgical clip harvest (31.4 vs. 36.9 minutes, respectively; p = 0.06). Two patients who underwent flap harvest with electrocautery and surgical clips developed postoperative donor site hematomas, whereas no donor site complications were noted in the Harmonic Scalpel group. Recipient site complication rates for infection, fistula, and hematoma were similar for both harvesting techniques (p = 0.77). Two flap failures occurred in the clip-assisted radial forearm free-flap harvest group, and none in the Harmonic Scalpel group. Median length of hospitalization was significantly reduced for patients who underwent free-flap harvest with the Harmonic Scalpel when compared with the other technique (7 vs. 8 days; p = 0.01). The Harmonic Scalpel is safe, and its use is feasible for radial forearm free-flap harvest.

  2. Protocol design and current status of CLIVIT: a randomized controlled multicenter relevance trial comparing clips versus ligatures in thyroid surgery

    PubMed Central

    Seiler, CM; Fröhlich, BE; Veit, JA; Gazyakan, E; Wente, MN; Wollermann, C; Deckert, A; Witte, S; Victor, N; Buchler, MW; Knaebel, HP

    2006-01-01

    Background Annually, more than 90000 surgical procedures of the thyroid gland are performed in Germany. Strategies aimed at reducing the duration of the surgical procedure are relevant to patients and the health care system especially in the context of reducing costs. However, new techniques for quick and safe hemostasis have to be tested in clinically relevance randomized controlled trials before a general recommendation can be given. The current standard for occlusion of blood vessels in thyroid surgery is ligatures. Vascular clips may be a safe alternative but have not been investigated in a large RCT. Methods/design CLIVIT (Clips versus Ligatures in Thyroid Surgery) is an investigator initiated, multicenter, patient-blinded, two-group parallel relevance randomized controlled trial designed by the Study Center of the German Surgical Society. Patients scheduled for elective resection of at least two third of the gland for benign thyroid disease are eligible for participation. After surgical exploration patients are randomized intraoperatively into either the conventional ligature group, or into the clip group. The primary objective is to test for a relevant reduction in operating time (at least 15 min) when using the clip technique. Since April 2004, 121 of the totally required 420 patients were randomized in five centers. Discussion As in all trials the different forms of bias have to be considered, and as in this case, a surgical trial, the role of surgical expertise plays a key role, and will be documented and analyzed separately. This is the first randomized controlled multicenter relevance trial to compare different vessel occlusion techniques in thyroid surgery with adequate power and other detailed information about the design as well as framework. If significant, the results might be generalized and may change the current surgical practice. PMID:16948853

  3. Preoperative computed tomography-guided percutaneous hookwire localization of metallic marker clips in the breast with a radial approach: initial experience.

    PubMed

    Uematsu, T; Kasami, M; Uchida, Y; Sanuki, J; Kimura, K; Tanaka, K; Takahashi, K

    2007-06-01

    Hookwire localization is the current standard technique for radiological marking of nonpalpable breast lesions. Stereotactic directional vacuum-assisted breast biopsy (SVAB) is of sufficient sensitivity and specificity to replace surgical biopsy. Wire localization for metallic marker clips placed after SVAB is needed. To describe a method for performing computed tomography (CT)-guided hookwire localization using a radial approach for metallic marker clips placed percutaneously after SVAB. Nineteen women scheduled for SVAB with marker-clip placement, CT-guided wire localization of marker clips, and, eventually, surgical excision were prospectively entered into the study. CT-guided wire localization was performed with a radial approach, followed by placement of a localizing marker-clip surgical excision. Feasibility and reliability of the procedure and the incidence of complications were examined. CT-guided wire localization surgical excision was successfully performed in all 19 women without any complications. The mean total procedure time was 15 min. The median distance on CT image from marker clip to hookwire was 2 mm (range 0-3 mm). CT-guided preoperative hookwire localization with a radial approach for marker clips after SVAB is technically feasible.

  4. Flat panel angiography images in the post-operative follow-up of surgically clipped intracranial aneurysms.

    PubMed

    Budai, Caterina; Cirillo, Luigi; Patruno, Francesco; Dall'olio, Massimo; Princiotta, Ciro; Leonardi, Marco

    2014-04-01

    Cerebral aneurysms must be monitored for varying periods after surgical and/or endovascular treatment and the duration of follow-up will depend on the type of therapy and the immediate post-operative outcome. Surgical clipping for intracranial aneurysms is a valid treatment but the metal clips generate artefacts so that follow-up monitoring still relies on catheter angiography. This study reports our preliminary experience with volumetric angiography using a Philips Allura Xper FD biplane system in the post-operative monitoring of aneurysm residues or major vascular changes following the surgical clipping of intracranial aneurysms. Volumetric angiography yields not only volume-rendered (VR) images, but a volume CT can also be reconstructed at high spatial and contrast resolution from a single acquisition, significantly enhancing the technique's diagnostic power. Between August 2012 and April 2013, we studied 19 patients with a total of 26 aneurysms treated by surgical clipping alone or in combination with endovascular treatment. All patients underwent standard post-operative angiographic follow-up including a rotational volumetric acquisition. Follow-up monitoring disclosed eight aneurysm residues whose assessment was optimal after surgical clipping both in patients with one metal clip and in those with two or more clips. In addition, small residues (1.3 mm) could be monitored together with any change in the calibre or course of vessels located adjacent to the clips. In conclusion, flat panel volume CT is much more reliable than the old 3D acquisitions that yielded only VR images. This is particularly true in patients with small aneurysm residues or lesions with multiple metal clips.

  5. Intraoperative Matas test using microscope-integrated intraoperative indocyanine green videoangiography with temporary unilateral occlusion of the A1 segment of the anterior cerebral artery.

    PubMed

    Murai, Yasuo; Adachi, Koji; Takagi, Ryo; Koketsu, Kenta; Matano, Fumihiro; Teramoto, Akira

    2011-11-01

    The aim of the present study was to assess a new technique of surgical microscope-based indocyanine green (ICG) videoangiography (VAG) to confirm the patency of the anterior communicating artery (AcomA) after clipping AcomA aneurysms. Aneurysmal clipping of five cases of unruptured, broad-neck AcomA aneurysm was performed using the Carl Zeiss Surgical Microscope OPMI Pentero INFRARED 800. In all five patients, after clipping AcomA aneurysms, the patency of AcomA was confirmed using ICGVAG findings and temporary unilateral occlusion of the A1 segment of the anterior cerebral artery using temporary clips. Images were excellent and enabled a real-time surgical assessment because the structures of interest, including vessels, perforating arteries, or residual aneurysm neck, were visible to the surgeon's eye under the microscope in all five patients. ICGVAG and temporary unilateral occlusion with clips provides a simple, reliable, real-time, and rapid intraoperative assessment of the patency of AcomA. This technique may help to improve the quality of neurosurgical procedures. Copyright © 2011 Elsevier Inc. All rights reserved.

  6. Evaluation of Sentinel Lymph Node Dose Distribution in 3D Conformal Radiotherapy Techniques in 67 pN0 Breast Cancer Patients.

    PubMed

    Witucki, Gerlo; Degregorio, Nikolaus; Rempen, Andreas; Schwentner, Lukas; Bottke, Dirk; Janni, Wolfgang; Ebner, Florian

    2015-01-01

    Introduction. The anatomic position of the sentinel lymph node is variable. The purpose of the following study was to assess the dose distribution delivered to the surgically marked sentinel lymph node site by 3D conformal radio therapy technique. Material and Method. We retrospectively analysed 70 radiotherapy (RT) treatment plans of consecutive primary breast cancer patients with a successful, disease-free, sentinel lymph node resection. Results. In our case series the SN clip volume received a mean dose of 40.7 Gy (min 28.8 Gy/max 47.6 Gy). Conclusion. By using surgical clip markers in combination with 3D CT images our data supports the pathway of tumouricidal doses in the SN bed. The target volume should be defined by surgical clip markers and 3D CT images to give accurate dose estimations.

  7. Use of a surgical rehearsal platform and improvement in aneurysm clipping measures: results of a prospective, randomized trial.

    PubMed

    Chugh, A Jessey; Pace, Jonathan R; Singer, Justin; Tatsuoka, Curtis; Hoffer, Alan; Selman, Warren R; Bambakidis, Nicholas C

    2017-03-01

    OBJECTIVE The field of neurosurgery is constantly undergoing improvements and advances, both in technique and technology. Cerebrovascular neurosurgery is no exception, with endovascular treatments changing the treatment paradigm. Clipping of aneurysms is still necessary, however, and advances are still being made to improve patient outcomes within the microsurgical treatment of aneurysms. Surgical rehearsal platforms are surgical simulators that offer the opportunity to rehearse a procedure prior to entering the operative suite. This study is designed to determine whether use of a surgical rehearsal platform in aneurysm surgery is helpful in decreasing aneurysm dissection time and clip manipulation of the aneurysm. METHODS The authors conducted a blinded, prospective, randomized study comparing key effort and time variables in aneurysm clip ligation surgery with and without preoperative use of the SuRgical Planner (SRP) surgical rehearsal platform. Initially, 40 patients were randomly assigned to either of two groups: one in which surgery was performed after use of the SRP (SRP group) and one in which surgery was performed without use of the SRP (control group). All operations were videotaped. After exclusion of 6 patients from the SRP group and 9 from the control group, a total of 25 surgical cases were analyzed by a reviewer blinded to group assignment. The videos were analyzed for total microsurgical time, number of clips used, and number of clip placement attempts. Means and standard deviations (SDs) were calculated and compared between groups. RESULTS The mean (± SD) amount of operative time per clip used was 920 ± 770 seconds in the SRP group and 1294 ± 678 seconds in the control group (p = 0.05). In addition, the mean values for the number of clip attempts, total operative time, ratio of clip attempts to clips used, and time per clip attempt were all lower in the SRP group, although the between-group differences were not statistically significant. CONCLUSIONS Preoperative rehearsal with SRP increased efficiency and safety in aneurysm microsurgery as demonstrated by the statistically significant improvement in time per clip used. Although the rest of the outcomes did not demonstrate statistically significant between-group differences, the fact that the SRP group showed improvement in mean values for all measures studied suggests that preoperative rehearsal may increase the efficiency and safety of aneurysm microsurgery. Future studies aimed at improving patient outcome and safety during surgical clipping of aneurysms will be needed to keep pace with the quickly advancing endovascular field.

  8. Practical Use of the Extended No Action Level (eNAL) Correction Protocol for Breast Cancer Patients With Implanted Surgical Clips

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Penninkhof, Joan, E-mail: j.penninkhof@erasmusmc.nl; Quint, Sandra; Baaijens, Margreet

    Purpose: To describe the practical use of the extended No Action Level (eNAL) setup correction protocol for breast cancer patients with surgical clips and evaluate its impact on the setup accuracy of both tumor bed and whole breast during simultaneously integrated boost treatments. Methods and Materials: For 80 patients, two orthogonal planar kilovoltage images and one megavoltage image (for the mediolateral beam) were acquired per fraction throughout the radiotherapy course. For setup correction, the eNAL protocol was applied, based on registration of surgical clips in the lumpectomy cavity. Differences with respect to application of a No Action Level (NAL) protocolmore » or no protocol were quantified for tumor bed and whole breast. The correlation between clip migration during the fractionated treatment and either the method of surgery or the time elapsed from last surgery was investigated. Results: The distance of the clips to their center of mass (COM), averaged over all clips and patients, was reduced by 0.9 {+-} 1.2 mm (mean {+-} 1 SD). Clip migration was similar between the group of patients starting treatment within 100 days after surgery (median, 53 days) and the group starting afterward (median, 163 days) (p = 0.20). Clip migration after conventional breast surgery (closing the breast superficially) or after lumpectomy with partial breast reconstructive techniques (sutured cavity). was not significantly different either (p = 0.22). Application of eNAL on clips resulted in residual systematic errors for the clips' COM of less than 1 mm in each direction, whereas the setup of the breast was within about 2 mm of accuracy. Conclusions: Surgical clips can be safely used for high-accuracy position verification and correction. Given compensation for time trends in the clips' COM throughout the treatment course, eNAL resulted in better setup accuracies for both tumor bed and whole breast than NAL.« less

  9. Focused opening of the sylvian fissure for microsurgical management of MCA aneurysms.

    PubMed

    Elsharkawy, Ahmed; Niemelä, Mika; Lehečka, Martin; Lehto, Hanna; Jahromi, Behnam Rezai; Goehre, Felix; Kivisaari, Riku; Hernesniemi, Juha

    2014-01-01

    A wide sylvian opening, with either a proximal or distal start, has been standard for microsurgical management of middle cerebral artery (MCA) aneurysms. However, extensive sylvian dissection is potentially associated with increased incidence of iatrogenic injury to the brain and neurovascular structures. The aim of the present study was to describe the technique of focused opening of the sylvian fissure for microsurgical management of MCA aneurysms with additional tips on handling difficulties which may be encountered with this technique. A 3D image-based anatomic orientation, clipping field-focused surgical planning, slack brain, and high magnification are the basic requirements for this approach. A 10-15 mm sylvian opening is placed so that it allows safe access and a good surgical view of the MCA aneurysm clipping field. Under proximal control of the MCA, the aneurysm neck can be dissected and clipped effectively and safely, in this small surgical field. The presented technique has been developed and refined by the senior author during the surgery of 1,097 aneurysms over the last 13 years. It has proved to be safe, and effective for clipping of both ruptured and unruptured MCA aneurysms. Its greatest advantages are a shorter operative time and less brain and vessel manipulation compared to more extensive approaches. The focused sylvian opening is a less-invasive alternative to the classical wide sylvian opening for the microsurgical management of most MCA aneurysms.

  10. Minimally Invasive Thumb-sized Pterional Craniotomy for Surgical Clip Ligation of Unruptured Anterior Circulation Aneurysms.

    PubMed

    Deshaies, Eric M; Villwock, Mark R; Singla, Amit; Toshkezi, Gentian; Padalino, David J

    2015-08-11

    Less invasive surgical approaches for intracranial aneurysm clipping may reduce length of hospital stay, surgical morbidity, treatment cost, and improve patient outcomes. We present our experience with a minimally invasive pterional approach for anterior circulation aneurysms performed in a major tertiary cerebrovascular center and compare the results with an aged matched dataset from the Nationwide Inpatient Sample (NIS). From August 2008 to December 2012, 22 elective aneurysm clippings on patients ≤55 years of age were performed by the same dual fellowship-trained cerebrovascular/endovascular neurosurgeon. One patient (4.5%) experienced transient post-operative complications. 18 of 22 patients returned for follow-up imaging and there were no recurrences through an average duration of 22 months. A search in the NIS database from 2008 to 2010, also for patients aged ≤55 years of age, yielded 1,341 hospitalizations for surgical clip ligation of unruptured cerebral aneurysms. Inpatient length of stay and hospital charges at our institution using the minimally invasive thumb-sized pterional technique were nearly half that of NIS (length of stay: 3.2 vs 5.7 days; hospital charges: $52,779 vs. $101,882). The minimally invasive thumb-sized pterional craniotomy allows good exposure of unruptured small and medium-sized supraclinoid anterior circulation aneurysms. Cerebrospinal fluid drainage from key subarachnoid cisterns and constant bimanual microsurgical techniques avoid the need for retractors which can cause contusions, localized venous infarctions, and post-operative cerebral edema at the retractor sites. Utilizing this set of techniques has afforded our patients with a shorter hospital stay at a lower cost compared to the national average.

  11. Training in Cerebral Aneurysm Clipping Using Self-Made 3-Dimensional Models.

    PubMed

    Mashiko, Toshihiro; Kaneko, Naoki; Konno, Takehiko; Otani, Keisuke; Nagayama, Rie; Watanabe, Eiju

    Recently, there have been increasingly fewer opportunities for junior surgeons to receive on-the-job training. Therefore, we created custom-built three-dimensional (3D) surgical simulators for training in connection with cerebral aneurysm clipping. Three patient-specific models were composed of a trimmed skull, retractable brain, and a hollow elastic aneurysm with its parent artery. The brain models were created using 3D printers via a casting technique. The artery models were made by 3D printing and a lost-wax technique. Four residents and 2 junior neurosurgeons attended the training courses. The trainees retracted the brain, observed the parent arteries and aneurysmal neck, selected the clip(s), and clipped the neck of an aneurysm. The duration of simulation was recorded. A senior neurosurgeon then assessed the trainee's technical skill and explained how to improve his/her performance for the procedure using a video of the actual surgery. Subsequently, the trainee attempted the clipping simulation again, using the same model. After the course, the senior neurosurgeon assessed each trainee's technical skill. The trainee critiqued the usefulness of the model and the effectiveness of the training course. Trainees succeeded in performing the simulation in line with an actual surgery. Their skills tended to improve upon completion of the training. These simulation models are easy to create, and we believe that they are very useful for training junior neurosurgeons in the surgical techniques needed for cerebral aneurysm clipping. Copyright © 2017 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  12. Near-real-time transcutaneous vascular clipping guided by magnetic resonance angiography: a minimally invasive technique for vascular control

    NASA Astrophysics Data System (ADS)

    Ennevor, Sean J.; Castro, Dan J.; Girardi, Gino; Lufkin, Robert B.; Farahani, Keyvan; Cho, Richard C.; Soudant, Jacques

    1993-07-01

    Interstitial tumor therapy guided by imaging techniques is minimally invasive and a promising surgical approach which will become clinically practical only when effective, simple, and safe modalities for tumor excision and control of tumor vascular supply are available. In a novel experiment utilizing a 1.5 T magnetic resonance (MR) scanner, the carotid artery of a New Zealand white rabbit was identified and then clamped using the Premium Surgicliptm 9.0' disposable automatic clip applier. The magnetic resonance imager equipped with an angiography package was used to locate vasculature in the carotid triangle of the rabbit via fast scan techniques. The artery was then clamped with titanium clips, and repeat magnetic resonance angiography (MRA) clearly demonstrated the cessation of blood flow within the chosen vessel. The experimental results are promising, since the angiography package not only provided the visualization of the arterial vessel, but was also used to guide an MR compatible surgical instrument to the vessel, with no artifact seen.

  13. Angiographic and epidemiological characteristics associated with aneurysm remnants after microsurgical clipping

    PubMed Central

    Dellaretti, Marcos; da Silva Martins, Warley Carvalho; Dourado, Jules Carlos; Faglioni, Wilson; Quadros, Ricardo Souza; de Souza Moraes, Vítor Vieira; de Souza Filho, Carlos Batista Alves

    2017-01-01

    Background: Despite new techniques for the treatment of cerebral aneurysms, the percentage of aneurysm remnants after surgical intervention seems to be relatively constant. The objective of this study was to assess angiographic and epidemiological features associated with aneurysm remnants after microsurgical clipping. Methods: This study was conducted from February 2009 to August 2012 on a series of 90 patients with 105 aneurysms referred to the Santa Casa of Belo Horizonte who were surgically treated and angiographically controlled. Results: Surgical clipping was considered incomplete in 13.3% of the aneurysms. The mean age of cases with an aneurysm remnant was 57.5 years, whereas the mean age without aneurysm remnant was 49.7 years (P = 0.02). Aneurysm remnants were detected more frequently on the internal carotid artery, nevertheless, no statistically significant differences were verified when comparing the locations. Aneurysm size in the preoperative angiography verified that the mean size of aneurysms operated was 6.56 mm, such that in cases showing a postoperative remnant, the mean size was 9.7 mm and in cases with complete clipping it was 6.08 mm (P = 0.02). Postoperative angiography showed that, in cases with residual aneurysm, the number of clips used was higher – a mean of 1.8 for complete clipping and 3.1 for incomplete clipping (P < 0.001). Conclusions: Aneurysm size and patient age showed significant correlations with residual intracranial aneurysm. The mean number of clips used was higher in cases with incomplete occlusion. PMID:28904825

  14. An Efficient Method for Hair Containment During Head and Neck Surgery.

    PubMed

    Zingaretti, Nicola; De Biasio, Fabrizio; Riccio, Michele; Marchesi, Andrea; Parodi, Pier Camillo

    2017-11-01

    The authors present a simple technique for operations around hair-bearing areas such as during a rhytidectomy. Hair surrounding the surgical field is twisted into bundles and clipped with duckbill clips. The authors repeat the procedure for each strand of hair. Between 5 and 7 duckbill clips may be required per surgery.The clippers are faster, easily applicable, and well performing. They can be used with different hair lengths, and they do not require any additional trimming or shaving; clips also keep the hair firmly in place, and they do not loosen up in the process.This technical note explains a very simple, economical, and less time-consuming method to control hair located around the surgical site. It may be applied to all procedures within the field of the hair-bearing scalp, including craniofacial and maxillofacial surgery.

  15. Tricuspid Clip: Step-by-Step and Clinical Data.

    PubMed

    Tang, Gilbert H L

    2018-01-01

    Symptomatic severe tricuspid regurgitation (TR), if untreated, carries a dismal prognosis. These patients are at very high risk for surgical repair or replacement and transcatheter options to treat TR are emerging. More than 300 transcatheter tricuspid repairs with the MitraClip system have been performed worldwide with promising results. The TriClip system, with the MitraClip NT delivered via a dedicated tricuspid steerable guide catheter, is currently under investigation. This article describes the step-by-step technique on using the MitraClip system to perform transcatheter tricuspid repair using echocardiographic and fluoroscopic guidance. The latest data on worldwide experience with tricuspid clipping are also discussed. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. Results of microsurgical treatment of large and giant ICA aneurysms using the retrograde suction decompression (RSD) technique: series of 92 patients.

    PubMed

    Eliava, Shalva S; Filatov, Yuri M; Yakovlev, Sergei B; Shekhtman, Oleg D; Kheireddin, Ali S; Sazonov, Ilya A; Sazonova, Olga B; Okishev, Dmitry N

    2010-06-01

    Microsurgical treatment of large and giant paraclinoid internal carotid artery (ICA) aneurysms often requires the use of the retrograde suction decompression (RSD) technique to facilitate clipping. Surgical results, functional outcomes at discharge, and technique limitations based on single institution series are presented. Between 1996 and 2009, eighty-three consecutive patients (19 to 68 years, mean 45.5 ± 9.9 years), predominantly women (69 women and 14 men) with large (23 patients, 27.7%) or giant (60 patients, 72.3%) paraclinoid aneurysms were surgically treated with the RSD technique performed by the neck route (62 patients, 74.4%) or later on, by endovascular means (21 patients, 25.3%). Patients were admitted after hemorrhage (48 patients, 57.9%), pseudotumor course (28 patients, 33.7%), mixed symptoms (5 patients, 6%), or asymptomatic (2 patients, 2.4%). In most RSD surgeries (90.4%) aneurysms were successfully excluded: neck was clipped in 57 patients (68.7%) or clipping with ICA reconstruction was achieved in 18 patients (21.7%). In six patients aneurysms were wrapped with glue (7.2%), trapped in one patient (1.2%), and in one patient, ICA balloon deconstruction was performed (1.2%). Good or excellent results (Glasgow Outcome Scale scores 4-5) at discharge were achieved in 69 patients (83.1%), 11 patients (13.3%) remained severely disabled (Glasgow Outcome Scale 3), and 3 patients died (3.6%). Surgical clipping with the RSD method remains a treatment of choice with acceptable outcomes for patients not amenable for endovascular treatment. Copyright © 2010 Elsevier Inc. All rights reserved.

  17. Post-Vacuum-Assisted Stereotactic Core Biopsy Clip Displacement: A Comparison Between Commercially Available Clips and Surgical Clip.

    PubMed

    Yen, Peggy; Dumas, Sandra; Albert, Arianne; Gordon, Paula

    2018-02-01

    The placement of localization clips following percutaneous biopsy is a standard practice for a variety of situations. Subsequent clip displacement creates challenges for imaging surveillance and surgical planning, and may cause confusion amongst radiologists and between surgeons and radiologists. Many causes have been attributed for this phenomenon including the commonly accepted "accordion effect." Herein, we investigate the performance of a low cost surgical clip system against 4 commercially available clips. We retrospectively reviewed 2112 patients who underwent stereotactic vacuum-assisted core biopsy followed by clip placement between January 2013 and June 2016. The primary performance parameter compared was displacement >10 mm following vacuum-assisted stereotactic core biopsy. Within the group of clips that had displaced, the magnitude of displacement was compared. There was a significant difference in displacement among the clip types (P < .0001) with significant pairwise comparisons between pediatric surgical clips and SecureMark (38% vs 28%; P = .001) and SenoMark (38% vs 27%; P = .0001) in the proportion displaced. The surgical clips showed a significant magnitude of displacement of approximately 25% greater average distance displaced. As a whole, the commercial clips performed better than the surgical clip after stereotactic vacuum-assisted core biopsy suggesting the surrounding outer component acts to anchor the central clip and minimizes clip displacement. The same should apply to tomosynthesis-guided biopsy. Crown Copyright © 2017. Published by Elsevier Inc. All rights reserved.

  18. Minimally Invasive Thumb-sized Pterional Craniotomy for Surgical Clip Ligation of Unruptured Anterior Circulation Aneurysms

    PubMed Central

    Deshaies, Eric M; Villwock, Mark R; Singla, Amit; Toshkezi, Gentian; Padalino, David J

    2015-01-01

    Less invasive surgical approaches for intracranial aneurysm clipping may reduce length of hospital stay, surgical morbidity, treatment cost, and improve patient outcomes. We present our experience with a minimally invasive pterional approach for anterior circulation aneurysms performed in a major tertiary cerebrovascular center and compare the results with an aged matched dataset from the Nationwide Inpatient Sample (NIS). From August 2008 to December 2012, 22 elective aneurysm clippings on patients ≤55 years of age were performed by the same dual fellowship-trained cerebrovascular/endovascular neurosurgeon. One patient (4.5%) experienced transient post-operative complications. 18 of 22 patients returned for follow-up imaging and there were no recurrences through an average duration of 22 months. A search in the NIS database from 2008 to 2010, also for patients aged ≤55 years of age, yielded 1,341 hospitalizations for surgical clip ligation of unruptured cerebral aneurysms. Inpatient length of stay and hospital charges at our institution using the minimally invasive thumb-sized pterional technique were nearly half that of NIS (length of stay: 3.2 vs 5.7 days; hospital charges: $52,779 vs. $101,882). The minimally invasive thumb-sized pterional craniotomy allows good exposure of unruptured small and medium-sized supraclinoid anterior circulation aneurysms. Cerebrospinal fluid drainage from key subarachnoid cisterns and constant bimanual microsurgical techniques avoid the need for retractors which can cause contusions, localized venous infarctions, and post-operative cerebral edema at the retractor sites. Utilizing this set of techniques has afforded our patients with a shorter hospital stay at a lower cost compared to the national average. PMID:26325337

  19. Virtual reality cerebral aneurysm clipping simulation with real-time haptic feedback.

    PubMed

    Alaraj, Ali; Luciano, Cristian J; Bailey, Daniel P; Elsenousi, Abdussalam; Roitberg, Ben Z; Bernardo, Antonio; Banerjee, P Pat; Charbel, Fady T

    2015-03-01

    With the decrease in the number of cerebral aneurysms treated surgically and the increase of complexity of those treated surgically, there is a need for simulation-based tools to teach future neurosurgeons the operative techniques of aneurysm clipping. To develop and evaluate the usefulness of a new haptic-based virtual reality simulator in the training of neurosurgical residents. A real-time sensory haptic feedback virtual reality aneurysm clipping simulator was developed using the ImmersiveTouch platform. A prototype middle cerebral artery aneurysm simulation was created from a computed tomographic angiogram. Aneurysm and vessel volume deformation and haptic feedback are provided in a 3-dimensional immersive virtual reality environment. Intraoperative aneurysm rupture was also simulated. Seventeen neurosurgery residents from 3 residency programs tested the simulator and provided feedback on its usefulness and resemblance to real aneurysm clipping surgery. Residents thought that the simulation would be useful in preparing for real-life surgery. About two-thirds of the residents thought that the 3-dimensional immersive anatomic details provided a close resemblance to real operative anatomy and accurate guidance for deciding surgical approaches. They thought the simulation was useful for preoperative surgical rehearsal and neurosurgical training. A third of the residents thought that the technology in its current form provided realistic haptic feedback for aneurysm surgery. Neurosurgical residents thought that the novel immersive VR simulator is helpful in their training, especially because they do not get a chance to perform aneurysm clippings until late in their residency programs.

  20. Surgical Treatment of Large or Giant Fusiform Middle Cerebral Artery Aneurysms: A Case Series.

    PubMed

    Xu, Feng; Xu, Bin; Huang, Lei; Xiong, Ji; Gu, Yuxiang; Lawton, Michael T

    2018-04-14

    Management of large or giant fusiform middle cerebral artery (MCA) aneurysms represents a significant challenge. To describe the authors' experience in the treatment of large or giant fusiform MCA aneurysm by using various surgical techniques. We retrospectively reviewed a database of aneurysms treated at our division between 2015 and 2017. Overall, 20 patients (11 males, 9 females) were identified, with a mean age of 40.7 years (range, 13-65 years; median, 43 years). Six patients (30%) had ruptured aneurysms and 14 (70%) had unruptured aneurysms. The mean aneurysm size was 19 mm (range, 10-35 mm). The aneurysms involved the prebifurcation in 5 cases, bifurcation in 4 cases, and postbifurcation in 11 cases. The aneurysms were treated by clip reconstruction (n = 5), clip wrapping (n = 1), proximal occlusion or trapping (n = 4), and bypass revascularization (n = 10). Bypasses included 7 low-flow superficial temporal artery-MCA bypasses, 2 high-flow extracranial-intracranial bypasses, and 1 intracranial-intracranial bypass (reanastomosis). Bypass patency was 90%. Nineteen aneurysms (95%) were completely obliterated, and no rehemorrhage occurred during follow-up. There was no procedural-related mortality. Clinical outcomes were good (modified Rankin Scale score ≤2) in 18 of 20 patients (90%) at the last follow-up. Surgical treatment strategy for large or giant fusiform MCA aneurysms should be determined on an individual basis, based on aneurysm morphology, location, size, and clinical status. Favorable outcomes can be achieved by various surgical techniques, including clip reconstruction, wrap clipping, aneurysm trapping, aneurysm excision followed by reanastomosis, and partial trapping with bypass revascularization. Copyright © 2018 Elsevier Inc. All rights reserved.

  1. Virtual Reality Cerebral Aneurysm Clipping Simulation With Real-time Haptic Feedback

    PubMed Central

    Alaraj, Ali; Luciano, Cristian J.; Bailey, Daniel P.; Elsenousi, Abdussalam; Roitberg, Ben Z.; Bernardo, Antonio; Banerjee, P. Pat; Charbel, Fady T.

    2014-01-01

    Background With the decrease in the number of cerebral aneurysms treated surgically and the increase of complexity of those treated surgically, there is a need for simulation-based tools to teach future neurosurgeons the operative techniques of aneurysm clipping. Objective To develop and evaluate the usefulness of a new haptic-based virtual reality (VR) simulator in the training of neurosurgical residents. Methods A real-time sensory haptic feedback virtual reality aneurysm clipping simulator was developed using the Immersive Touch platform. A prototype middle cerebral artery aneurysm simulation was created from a computed tomography angiogram. Aneurysm and vessel volume deformation and haptic feedback are provided in a 3-D immersive VR environment. Intraoperative aneurysm rupture was also simulated. Seventeen neurosurgery residents from three residency programs tested the simulator and provided feedback on its usefulness and resemblance to real aneurysm clipping surgery. Results Residents felt that the simulation would be useful in preparing for real-life surgery. About two thirds of the residents felt that the 3-D immersive anatomical details provided a very close resemblance to real operative anatomy and accurate guidance for deciding surgical approaches. They believed the simulation is useful for preoperative surgical rehearsal and neurosurgical training. One third of the residents felt that the technology in its current form provided very realistic haptic feedback for aneurysm surgery. Conclusion Neurosurgical residents felt that the novel immersive VR simulator is helpful in their training especially since they do not get a chance to perform aneurysm clippings until very late in their residency programs. PMID:25599200

  2. Clips versus suture technique: is there a difference?

    PubMed

    Chughtai, T; Chen, L Q; Salasidis, G; Nguyen, D; Tchervenkov, C; Morin, J F

    2000-11-01

    Coronary artery bypass grafting (CABG) is one of the most common procedures performed today, and wound complications are a major source of morbidity and cost. To determine whether there is any difference in wound outcome (including cost in a Canadian context) between a subcuticular suture technique and skin stapling technique for closure of sternal and leg incisions in CABG patients. One hundred and sixty-two patients undergoing CABG were prospectively, randomly placed to have their sternal and leg incisions closed with either a subcuticular suture technique or with a skin clip. Data were obtained through chart review, in-hospital assessments and follow-up visits. Nonblinded assessments were made regarding wound leakage, inflammation, infection, necrosis, swelling, dehiscence and cosmesis. Each of the parameters was graded on a scale from 1 to 4. The cost was evaluated in Canadian dollars. There were trends toward increased rates of in-hospital sternal (P=0.09) and leg (P=0.17) incision inflammation when the wounds were closed with skin clips. There was a significantly greater (P=0.05) rate of sternal wound infection with clips, as well as a tendency (P=0.15) toward a greater rate of mediastinitis at follow-up assessment. Cosmetic outcome was similar for both groups. The cost incurred was significantly greater when skin clips were used for closure. There was a greater than threefold difference, which translates to a greater than $10,000 difference over one year. Closure with a subcuticular technique achieves better outcomes than the use of skin clips. When factoring in the increased cost incurred by using clips, as well as other intangible factors such as surgical skill acquisition, subcuticular suture closure appears to be a favourable method of wound closure in CABG patients compared with the use of skin stapling techniques.

  3. Advanced technical skills are required for microsurgical clipping of posterior communicating artery aneurysms in the endovascular era.

    PubMed

    Sanai, Nader; Caldwell, Nolan; Englot, Dario J; Lawton, Michael T

    2012-08-01

    Many neurosurgeons feel competent clipping posterior communicating artery (PCoA) aneurysms and include this lesion in their practice. However, endovascular therapy removes simple aneurysms that would have been easiest to clip with the best results. What remains are aneurysms with complex anatomy and technical challenges that are not well described. A contemporary surgical series with PCoA aneurysms is reviewed to define the patients, microsurgical techniques, and outcomes in current practice. A total of 218 patients had 218 PCoA aneurysms that were treated microsurgically during an 11-year period. Complexities influencing aneurysm management included (1) large/giant size; (2) fetal posterior cerebral artery; (3) previous coiling; (4) anterior clinoidectomy; (5) adherence of the anterior choroidal artery (AChA); (6) intraoperative aneurysm rupture; (7) complex clipping; and (8) atherosclerotic calcification. Simple PCoA aneurysms were encountered in 113 patients (51.8%) and complex aneurysms in 105 (48.2%). Adherent AChA (13.8%) and intraoperative rupture (11.5%) were the most common complexities. Simple aneurysms had favorable outcomes in 86.6% of patients, whereas aneurysms with 1 or multiple complexities had favorable outcomes in 78.2% and 75.0%, respectively. Intraoperative rupture (P < .01), large/giant size (P = .04), and complex clipping (P = .05) were associated with increased neurological worsening. Because endovascular therapy alters the surgical population, neurosurgeons should recalibrate their expectations with this once straightforward aneurysm. The current mix of PCoA aneurysms requires advanced techniques including clinoidectomy, AChA microdissection, complex clipping, and facility with intraoperative rupture. Microsurgery is recommended for recurrent aneurysms after coiling, complex branches, aneurysms causing oculomotor nerve palsy, multiple aneurysms, and patients with hematomas.

  4. The efficiency of the new Yasargil titanium fenestrated mini-clips for ideal clipping of a cerebral aneurysm

    PubMed Central

    Ota, Nakao; Tanikawa, Rokuya; Noda, Kosumo; Tsuboi, Toshiyuki; Kamiyama, Hiroyasu; Tokuda, Sadahisa

    2015-01-01

    Background: The fenestrated clip is sometimes useful in limited approach angle and narrow working space. However, before the development of the new Yasargil titanium fenestrated mini-clip, the only variations of fenestrated clips were those of larger sizes. And those larger clips have a problem of the triangle-shaped gap at the proximal end of the blade. The authors describe the efficiency, limitations and surgical technique of using the Yasargil titanium fenestrated mini-clip. Methods: Fifty-nine cases of aneurysms were treated using these mini-clips. Aneurysm location, size and dome neck ratio, mean follow-up period, neck remnant, and recurrence rate were also analyzed. Among these cases, we present eight characteristic cases, including a case with aneurysm recurrence, and we review the problems associated with the triangle-shaped gap at the proximal end of the clip. Results: The average size of the aneurysms was 5.57 mm, and the dome neck ratio was >2.0 in 1.69%, >1.5 in 11.8%, >1.2 in 35.6%, and <1.2 in 50.8% of cases. The mean follow-up period for the 59 cases was 5.5 months (range, 0.5–16 months). Angiographic recurrence of the treated portion occurred in 1 case (1.7%), including an aneurysm in the basilar artery tip aneurysm. Conclusion: The availability of the Yasargil titanium fenestrated mini-clip increases the options for clipping to minimize the remnant of the clipped aneurysm. However, there is still concern over the triangular space at the base of the blade, especially when treating an aneurysm with a thin vessel wall. Therefore, modification of the clipping technique is sometimes needed. PMID:26664871

  5. Three-Dimensional Printing of Surgical Clips: An In Vitro Pilot Study and Trial of Efficacy.

    PubMed

    Canvasser, Noah E; De, Shuvro; Koseoglu, Ersin; Lay, Aaron H; Sorokin, Igor; Fernandez, Raul; Cadeddu, Jeffrey A

    2017-09-01

    Three-dimensional (3D) printing applications have increased over the past decade. Our objective was to test rapid prototyping of a 3D printed surgical clip for intraoperative use. Our prototype was modeled after the 10 mm Weck ® Hem-o-lok ® polymer clip (Teleflex, Inc., Wayne, PA). A 3D computer-aided design model of the Hem-o-lok clip was reverse engineered using commercial microscopy and printing was done using an Objet Connex500 multijetting system (Stratasys, Eden Prairie, MN). The initial polymer was Objet VeroWhitePlus RGD835; the addition of Objet TangoBlackPlus FLX980 during the design process improved hinge flexibility. The 3D printed clips were then pressure tested on rubber Penrose tubing and compared in vitro versus commercial Hem-o-lok clips. Initial 3D printed clips were not functional as they split at the hinge upon closure of the clip jaws. Design changes were made to add Objet TangoBlackPlus FLX980 at the hinge to improve flexibility. Additional modifications were made to allow for clips to be compatible with the Hem-o-lok endoscopic clip applier. A total of 50 clips were tested. Fracture rate for the printed clips using a clip applier was 54% (n = 27), whereas none of the commercial Hem-o-lok clips broke upon closure. Of the 23 printed clips that closed, mean leak was at 20.7 κPa (range 4.8-42.7). In contrast, none of the commercial clips leaked, and fill continued until Penrose rupture at mean 46.2 κPa (44.8-47.6). This pilot study demonstrates feasibility of 3D printing functional surgical clips. However, the performance of our first generation clips is poor compared with commercial grade product. Refinement in printers and materials available may allow for customization of such printed surgical instruments that could be economically competitive to purchasing and stocking product.

  6. Virtual Cerebral Aneurysm Clipping with Real-Time Haptic Force Feedback in Neurosurgical Education.

    PubMed

    Gmeiner, Matthias; Dirnberger, Johannes; Fenz, Wolfgang; Gollwitzer, Maria; Wurm, Gabriele; Trenkler, Johannes; Gruber, Andreas

    2018-04-01

    Realistic, safe, and efficient modalities for simulation-based training are highly warranted to enhance the quality of surgical education, and they should be incorporated in resident training. The aim of this study was to develop a patient-specific virtual cerebral aneurysm-clipping simulator with haptic force feedback and real-time deformation of the aneurysm and vessels. A prototype simulator was developed from 2012 to 2016. Evaluation of virtual clipping by blood flow simulation was integrated in this software, and the prototype was evaluated by 18 neurosurgeons. In 4 patients with different medial cerebral artery aneurysms, virtual clipping was performed after real-life surgery, and surgical results were compared regarding clip application, surgical trajectory, and blood flow. After head positioning and craniotomy, bimanual virtual aneurysm clipping with an original forceps was performed. Blood flow simulation demonstrated residual aneurysm filling or branch stenosis. The simulator improved anatomic understanding for 89% of neurosurgeons. Simulation of head positioning and craniotomy was considered realistic by 89% and 94% of users, respectively. Most participants agreed that this simulator should be integrated into neurosurgical education (94%). Our illustrative cases demonstrated that virtual aneurysm surgery was possible using the same trajectory as in real-life cases. Both virtual clipping and blood flow simulation were realistic in broad-based but not calcified aneurysms. Virtual clipping of a calcified aneurysm could be performed using the same surgical trajectory, but not the same clip type. We have successfully developed a virtual aneurysm-clipping simulator. Next, we will prospectively evaluate this device for surgical procedure planning and education. Copyright © 2018 Elsevier Inc. All rights reserved.

  7. Early retreatment after surgical clipping of ruptured intracranial aneurysms.

    PubMed

    Ito, Yoshiro; Yamamoto, Tetsuya; Ikeda, Go; Tsuruta, Wataro; Uemura, Kazuya; Komatsu, Yoji; Matsumura, Akira

    2017-09-01

    Although a rerupture after surgical clipping of ruptured intracranial aneurysms is rare, it is associated with high morbidity and mortality. The causes for retreatment and rupture after surgical clipping are not clearly defined. From a prospectively maintained database of 244 patients who had undergone surgical clipping of ruptured intracranial aneurysms, we selected patients who experienced retreatment or rerupture within 30 days after surgical clipping. Aneurysm occlusions were examined by microvascular Doppler ultrasonography and indocyanine green video-angiography. Indications for retreatment included rerupture and partial occlusion. We analyzed the characteristics and causes of early retreatment. Six patients (2.5%, 95% CI 0.9 to 5.3%) were retreated within 30 days after surgical clipping, including two patients (0.8%, 95% CI 0.1 to 2.9%) who experienced a rerupture. The retreated aneurysms were found in the anterior communicating artery (AcomA) (n = 5) and basilar artery (n = 1). Retreatment of the AcomA (7.5%) was performed significantly more frequently than that of other arteries (0.56%) (p < 0.01). A laterally projected AcomA aneurysm (17.4%) was more frequently retreated than were other aneurysm types (2.3%). Cases of laterally projecting AcomA aneurysms tended to result from an incomplete clip placed using a pterional approach from the opposite side of the aneurysm projection. Despite developments, the rates of retreatment and rerupture after surgical clipping remain similar to those reported previously. Retreatment of the AcomA was significantly more frequent than was retreatment of other arteries. Patients underwent retreatment more frequently when they were originally treated for lateral type aneurysms using a pterional approach from the opposite side of the aneurysm projection. The treatment method and evaluation modalities should be considered carefully for AcomA aneurysms in particular.

  8. Ovarian cryopreservation after laparoscopic ovariectomy using the Endo-GIA stapling device and LAPRO-clip absorbable ligating clip in a woman: a case report

    PubMed Central

    2011-01-01

    Introduction Several options are available for preserving fertility before cytotoxic treatment, including ovarian tissue cryopreservation. Most reported surgical techniques include electrocoagulation. Our hypothesis is that avoidance of electrocoagulation may decrease ovarian cortex injury during cryopreservation procedures. Case presentation We report a laparoscopic technique of whole-ovary removal without coagulation using Endo-GIA forceps and clips. Laparoscopic ovariectomy was performed for cryopreservation in a 37-year-old Caucasian woman with breast cancer and for whom chemotherapy was planned. The procedure was completed quickly and without complication. This Endo-GIA procedure was of short duration with a short period of ischemia before freezing. Conclusion Laparoscopic ovariectomy using the Endo-GIA stapling device procedure without coagulation may diminish ovary injury before ovarian cryopreservation. PMID:21291518

  9. Ischemic mass effect from biliary surgical clips.

    PubMed

    Mateo, Rod; Tsai, Steven; Stapfer, Maria V; Sher, Linda S; Selby, Rick; Genyk, Yuri S

    2008-02-01

    Migrating surgical clips in the hepatic hilum are known causes of biliary stricture or obstruction, most often due to direct intraluminal obstruction or secondary stone formation. Two cases are reported on patients with previous cholecystectomies presenting with delayed symptoms of biliary tract stricture. Both patients were successfully treated with a resection of the strictured area and a Roux-en-Y hepatico-jejunostomy. Resected specimens grossly demonstrated surgical clips adjacent to the stricture, but not directly within the lumen, suggestive of an ischemic mass effect, which was supported by histology. In addition to the direct intraluminal obstruction and lithogenic effects of migratory surgical clips, "clipomas" due to an ischemic mass effect can also lead to biliary tract strictures.

  10. Patient-specific cardiac phantom for clinical training and preprocedure surgical planning.

    PubMed

    Laing, Justin; Moore, John; Vassallo, Reid; Bainbridge, Daniel; Drangova, Maria; Peters, Terry

    2018-04-01

    Minimally invasive mitral valve repair procedures including MitraClip ® are becoming increasingly common. For cases of complex or diseased anatomy, clinicians may benefit from using a patient-specific cardiac phantom for training, surgical planning, and the validation of devices or techniques. An imaging compatible cardiac phantom was developed to simulate a MitraClip ® procedure. The phantom contained a patient-specific cardiac model manufactured using tissue mimicking materials. To evaluate accuracy, the patient-specific model was imaged using computed tomography (CT), segmented, and the resulting point cloud dataset was compared using absolute distance to the original patient data. The result, when comparing the molded model point cloud to the original dataset, resulted in a maximum Euclidean distance error of 7.7 mm, an average error of 0.98 mm, and a standard deviation of 0.91 mm. The phantom was validated using a MitraClip ® device to ensure anatomical features and tools are identifiable under image guidance. Patient-specific cardiac phantoms may allow for surgical complications to be accounted for preoperative planning. The information gained by clinicians involved in planning and performing the procedure should lead to shorter procedural times and better outcomes for patients.

  11. Spring clip sterilization: one-year follow-up of 1,079 cases.

    PubMed

    Hulka, J F; Mercer, J P; Fishburne, J I; Kumarasamy, T; Omran, K F; Phillips, J M; Lefler, H T; Lieberman, B; Lean, T H; Pai, D N; Koetsawang, S; Castro, M V

    1976-08-15

    This is a report of 1,079 patients who underwent laparoscopic clip sterlization as of March, 1974. A one-year follow-up was obtained on 977 patients, or 90.5 per cent. Complications due to the clip technique appear limited to postoperative cramps for 24 to 48 hours in 26 per cent of patients. No ectopic pregnancies were detected. Pregnancies, when corrected for unsuspected existing pregnancies and surgical and manufacturing errors, occurred in 2 to 6 cases, for a method failure rate of 2 to 6/1,000. This report documents that experienced laparoscopists can perform this practice with local anesthesia, in combination with first-trimester abortion, and in hospital facilities other than an operating room.

  12. Intraoperative loss of core biopsy clips: clinical implications.

    PubMed

    Calhoun, Kristine; Giuliano, Armando; Brenner, R James

    2008-03-01

    The purpose of this study was to report the occurrence of intraoperative loss of metallic marking clips placed during image-guided biopsy and to hypothesize the likely mechanism of this clinical problem. From January 2003 through December 2004, patients presenting for preoperative mammographic localization and operative excision of biopsy site marking clips were identified. Age, method of image-guided biopsy, number of excised specimens, and tissue diagnosis were determined. Specimen radiographs were used to identify cases of suspected intraoperative clip loss. Clips absent on specimen radiographs and postoperative mammograms were defined as lost intraoperatively. Biopsy site marking clips, surgical clips, and suction device apertures were measured. In 78 surgical procedures performed during the study period, three (3.8%) of the patients experienced clip loss. Specimen radiographs confirmed the absence of clips in all submitted tissues. A median of four (range, three to five) separate biopsy specimens were excised among these three cases. A healing biopsy site from the stereotactic biopsy preceding the clip placement procedure was confirmed in all cases. Absence of the metallic clip was confirmed on postoperative mammograms. The apertures of two types of suction device were four and two times those of the biopsy clips. Intraoperative loss of metallic clips placed at the conclusion of image-guided breast biopsy is unusual but can occur during subsequent surgical excision. Repeated inability to locate the clip on specimen radiographs after accurate preoperative localization should raise the suspicion that the target clip has been lost, not missed, during surgery, likely because of inadvertent removal of the clip with the suction device.

  13. Adjunctive intracardiac echocardiography imaging from the left ventricle to guide percutaneous mitral valve repair with the MitraClip in patients with failed prior surgical rings.

    PubMed

    Saji, Mike; Rossi, Ann M; Ailawadi, Gorav; Dent, John; Ragosta, Michael; Lim, D Scott

    2016-02-01

    We evaluated intracardiac echocardiography (ICE) for adjunctively guiding the MitraClip procedure in patients with prior surgical rings. Transesophageal echocardiography (TEE) is the standard imaging modality used to guide the MitraClip procedure (Abbott Vascular, CA). However, in patients with post-surgical anatomy, clear imaging of the mitral valve leaflets may be complex because of shadowing from the surgical ring. In these patients, TEE may be suboptimal for guiding the procedure, even using three-dimensional imaging. This retrospective analysis included data from 121 consecutive patients with mitral regurgitation who underwent MitraClip procedures at the University of Virginia. ICE was used adjunctively when there was difficulty with TEE, particularly for assessing the insertion of the posterior leaflet into the MitraClip's arms. The ICE catheter was introduced transarterially into the left ventricle and flexed to obtain the short-axis view. Six patients had prior surgical rings, and in five, we used adjunctive ICE. The etiology of the mitral regurgitation was prolapse of the posterior leaflet in one patient and restriction of the posterior leaflet due to ischemic tethering in the remainder. All images were obtained from the left ventricle, and were adequate for assessing posterior leaflet insertion and the perpendicularity of the MitraClip arms. The procedural success rate was 80%. There was no adverse event related to the ICE procedure. Mitral valve repair with the MitraClip system assisted by ICE is feasible in patients with prior surgical rings, achieving an excellent risk profile and satisfactory procedural success. © 2015 Wiley Periodicals, Inc.

  14. Microsurgical clipping of ophthalmic artery aneurysms: surgical results and visual outcomes with 208 aneurysms.

    PubMed

    Kamide, Tomoya; Tabani, Halima; Safaee, Michael M; Burkhardt, Jan-Karl; Lawton, Michael T

    2018-01-26

    OBJECTIVE While most paraclinoid aneurysms can be clipped with excellent results, new postoperative visual deficits are a concern. New technology, including flow diverters, has increased the popularity of endovascular therapy. However, endovascular treatment of paraclinoid aneurysms is not without procedural risks, is associated with higher rates of incomplete aneurysm occlusion and recurrence, and may not address optic nerve compression symptoms that surgical debulking can. The increasing endovascular management of paraclinoid aneurysms should be justified by comparisons to surgical benchmarks. The authors, therefore, undertook this study to define patient, visual, and aneurysm outcomes in the most common type of paraclinoid aneurysm: ophthalmic artery (OphA) aneurysms. METHODS Results from microsurgical clipping of 208 OphA aneurysms in 198 patients were retrospectively reviewed. Patient demographics, aneurysm morphology (size, calcification, etc.), clinical characteristics, and patient outcomes were recorded and analyzed. RESULTS Despite 20% of these aneurysms being large or giant in size, complete aneurysm occlusion was accomplished in 91% of 208 cases, with OphA patency preserved in 99.5%. The aneurysm recurrence rate was 3.1% and the retreatment rate was 0%. Good outcomes (modified Rankin Scale score 0-2) were observed in 96.2% of patients overall and in all 156 patients with unruptured aneurysms. New visual field defects (hemianopsia or quadrantanopsia) were observed in 8 patients (3.8%), decreased visual acuity in 5 (2.4%), and monocular blindness in 9 (4.3%). Vision improved in 9 (52.9%) of the 17 patients with preoperative visual deficits. CONCLUSIONS The most important risk associated with clipping OphA aneurysms is a new visual deficit. Meticulous microsurgical technique is necessary during anterior clinoidectomy, aneurysm dissection, and clip application to optimize visual outcomes, and aggressive medical management postoperatively might potentially decrease the incidence of delayed visual deficits. As the results of endovascular therapy and specifically flow diverters become known, they warrant comparison with these surgical benchmarks to determine best practices.

  15. Left Atrial Appendage Closure for Stroke Prevention: Devices, Techniques, and Efficacy.

    PubMed

    Iskandar, Sandia; Vacek, James; Lavu, Madhav; Lakkireddy, Dhanunjaya

    2016-05-01

    Left atrial appendage closure can be performed either surgically or percutaneously. Surgical approaches include direct suture, excision and suture, stapling, and clipping. Percutaneous approaches include endocardial, epicardial, and hybrid endocardial-epicardial techniques. Left atrial appendage anatomy is highly variable and complex; therefore, preprocedural imaging is crucial to determine device selection and sizing, which contribute to procedural success and reduction of complications. Currently, the WATCHMAN is the only device that is approved for left atrial appendage closure in the United States. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. Surgical margin-negative endoscopic mucosal resection with simple three-clipping technique: a randomized prospective study (with video).

    PubMed

    Mori, Hirohito; Kobara, Hideki; Nishiyama, Noriko; Fujihara, Shintaro; Kobayashi, Nobuya; Ayaki, Maki; Masaki, Tsutomu

    2016-11-01

    Although endoscopic mucosal resection is an established colorectal polyp treatment, local recurrence occurs in 13 % of cases due to inadequate snaring. We evaluated whether pre-clipping to the muscularis propria resulted in resected specimens with negative surgical margins without thermal denaturation. Of 245 polyps from 114 patients with colorectal polyps under 20 mm, we included 188 polyps from 81 patients. We randomly allocated polyps to the conventional injection group (CG) (97 polyps) or the pre-clipping injection group (PG) (91 polyps). The PG received three-point pre-clipping to ensure ample gripping to the muscle layer on the oral and both sides of the tumor with 4 mL local injection. Endoscopic ultrasonography was performed to measure the resulting bulge. Outcomes included the number of instances of thermal denaturation of the horizontal/vertical margin (HMX/VMX) or positive horizontal/vertical margins (HM+/VM+), the shortest distance from tumor margins to resected edges, and the maximum bulge distances from tumor surface to the muscularis propria. The numbers of HMX and HM+ in the CG and PG were 27 and 6, and 9 and 2 (P = 0.001), and VMX and VM+ were 8 and 5, and 0 and 0 (P = 0.057). The shortest distance from tumor margin to resected edge [median (range), mm] in polyps in the CG and PG was 0.6 (0-2.7) and 4.7 (2.1-8.9) (P = 0.018). The maximum bulge distances were 4.6 (3.0-8.0) and 11.0 (6.8-17.0) (P = 0.005). Pre-clipping enabled surgical margin-negative resection without thermal denaturation.

  17. Impact of Aneurysm Projection on Intraoperative Complications During Surgical Clipping of Ruptured Posterior Communicating Artery Aneurysms.

    PubMed

    Fukuda, Hitoshi; Hayashi, Kosuke; Yoshino, Kumiko; Koyama, Takashi; Lo, Benjamin; Kurosaki, Yoshitaka; Yamagata, Sen

    2016-03-01

    Surgical clipping of ruptured posterior communicating artery (PCoA) aneurysms is a well-established procedure to date. However, preoperative factors associated with procedure-related risk require further elucidation. To investigate the impact of the direction of aneurysm projection on the incidence of procedure-related complications during surgical clipping of ruptured PCoA aneurysms. A total of 65 patients with ruptured PCoA aneurysms who underwent surgical clipping were retrospectively analyzed from a single-center, prospective, observational cohort database in this study. The aneurysms were categorized into lateral and posterior projection groups, depending on direction of the dome. Characteristics and operative findings of each projection group were identified. We also evaluated any correlation of aneurysm projection with the incidence of procedure-related complications. Patients with ruptured PCoA aneurysms with posterior projection more likely presented with good-admission-grade subarachnoid hemorrhage (P = .01, χ test) and were less to also have intracerebral hematoma (P = .01). These aneurysms were found to be associated with higher incidence of intraoperative rupture (P = .02), complex clipping with fenestrated clips (P = .02), and dense adherence to PCoA or its perforators (P = .04) by univariate analysis. Aneurysms with posterior projection were also correlated with procedure-related complications, including postoperative cerebral infarction or hematoma formation (odds ratio, 5.87; 95% confidence interval, 1.11-31.1; P = .04) by multivariable analysis. Ruptured PCoA aneurysms with posterior projection carried a higher risk of procedure-related complications of surgical clipping than those with lateral projection.

  18. Assessment of MRI issues at 3-Tesla for metallic surgical implants: findings applied to 61 additional skin closure staples and vessel ligation clips.

    PubMed

    Gill, Amreeta; Shellock, Frank G

    2012-01-09

    Metallic skin closure staples and vessel ligation clips should be tested at 3-Tesla to characterize MRI issues in order to ensure patient safety. Therefore, metallic surgical implants were assessed at 3-Tesla for magnetic field interactions, MRI-related heating, and artifacts. A skin closure staple (Visistat Skin Stapler, staple, Polytetrafluoroethylene, PTFE, coated 316L/316LVM stainless steel; Teleflex Medical, Durham, NC) and a vessel ligation clip (Hemoclip Traditional, stainless steel; Teleflex Medical, Durham, NC) that represented the largest metallic sizes made from materials with the highest magnetic susceptibilities (i.e., based on material information) among 61 other surgical implants (52 metallic implants, 9 nonmetallic implants) underwent evaluation for magnetic field interactions, MRI-related heating, and artifacts using standardized techniques. MRI-related heating was assessed by placing each implant in a gelled-saline-filled phantom with MRI performed using a transmit/receive RF body coil at an MR system reported, whole body averaged SAR of 2.9-W/kg for 15-min. Artifacts were characterized using T1-weighted, SE and GRE pulse sequences. Each surgical implant showed minor magnetic field interactions (20- and 27-degrees, which is acceptable from a safety consideration). Heating was not substantial (highest temperature change, ≤ 1.6°C). Artifacts may create issues if the area of interest is in the same area or close to the respective surgical implant. The results demonstrated that it would be acceptable for patients with these metallic surgical implants to undergo MRI at 3-Tesla or less. Because of the materials and dimensions of the surgical implants that underwent testing, these findings pertain to 61 additional similar implants.

  19. Assessment of MRI issues at 3-Tesla for metallic surgical implants: findings applied to 61 additional skin closure staples and vessel ligation clips

    PubMed Central

    2012-01-01

    Purpose Metallic skin closure staples and vessel ligation clips should be tested at 3-Tesla to characterize MRI issues in order to ensure patient safety. Therefore, metallic surgical implants were assessed at 3-Tesla for magnetic field interactions, MRI-related heating, and artifacts. Methods A skin closure staple (Visistat Skin Stapler, staple, Polytetrafluoroethylene, PTFE, coated 316L/316LVM stainless steel; Teleflex Medical, Durham, NC) and a vessel ligation clip (Hemoclip Traditional, stainless steel; Teleflex Medical, Durham, NC) that represented the largest metallic sizes made from materials with the highest magnetic susceptibilities (i.e., based on material information) among 61 other surgical implants (52 metallic implants, 9 nonmetallic implants) underwent evaluation for magnetic field interactions, MRI-related heating, and artifacts using standardized techniques. MRI-related heating was assessed by placing each implant in a gelled-saline-filled phantom with MRI performed using a transmit/receive RF body coil at an MR system reported, whole body averaged SAR of 2.9-W/kg for 15-min. Artifacts were characterized using T1-weighted, SE and GRE pulse sequences. Results Each surgical implant showed minor magnetic field interactions (20- and 27-degrees, which is acceptable from a safety consideration). Heating was not substantial (highest temperature change, ≤ 1.6°C). Artifacts may create issues if the area of interest is in the same area or close to the respective surgical implant. Conclusions The results demonstrated that it would be acceptable for patients with these metallic surgical implants to undergo MRI at 3-Tesla or less. Because of the materials and dimensions of the surgical implants that underwent testing, these findings pertain to 61 additional similar implants. PMID:22230200

  20. Utility of nonpenetrating titanium clips for dural closure during spinal surgery to prevent postoperative cerebrospinal fluid leakage.

    PubMed

    Ito, Kiyoshi; Aoyama, Tatsuro; Horiuchi, Tetsuyoshi; Hongo, Kazuhiro

    2015-12-01

    The nonpenetrating titanium clip has been successfully used in peripheral arterial bypass surgery. The purpose of this study was to evaluate the leakage pressures and patterns of nonpenetrating titanium clips using a simple model that mimicked spinal surgery. In addition, the authors describe their surgical experience with these clips and the follow-up results in 31 consecutive patients. The authors compared nonpenetrating titanium clips and expanded polytetrafluoroethylene (ePTFE) sutures in relation to the water pressure that could be tolerated by sutured ePTFE sheets, and the leakage pressure patterns were determined. The changes in leakage pressures at 5 minutes, 30 minutes, and 12 hours were examined when the clips and sutures were used in combination with the mesh-and-glue technique in an in vitro study. Thirty-one patients underwent spinal intradural procedures using nonpenetrating titanium clips to suture the dura maters using the meshand-glue technique, involving fibrin glue and polyglycolic acid-fibrin sheets. A significant difference was apparent between the ePTFE suture group and the nonpenetrating titanium clip group, with the latter showing a leakage pressure that could be sustained and was 1508% higher than that of the former (p = 0.001). In relation to leakage patterns, the nonpenetrating titanium clips did not make any suture holes in the ePTFE sheet and fluid leakage occurred between the clips, whereas fluid leakage was associated with the pressure elevation that occurred at the suture holes made by the ePTFE sutures. Of the 31 patients who underwent spinal intradural procedures using nonpenetrating titanium clips, 1 (3.2%) experienced cerebrospinal fluid (CSF) leakage postoperatively. No other complications-for example, allergic reactions, adhesions, or infections--were encountered. The interrupted placement of nonpenetrating titanium clips enables dural closure without creating any holes. These clips facilitate improvements in the initial leakage pressure and reduce postoperative CSF leakage following spinal surgery. The authors conclude that it is very beneficial to suture the spinal dura mater using nonpenetrating titanium clips given the anatomical characteristics of the spinal dura mater and the fact that the clips do not create suture holes.

  1. Ocular Biocompatibility of Nitinol Intraocular Clips

    PubMed Central

    Velez-Montoya, Raul; Erlanger, Michael

    2012-01-01

    Purpose. To evaluate the tolerance and biocompatibility of a preformed nitinol intraocular clip in an animal model after anterior segment surgery. Methods. Yucatan mini-pigs were used. A 30-gauge prototype injector was used to attach a shape memory nitinol clip to the iris of five pigs. Another five eyes received conventional polypropylene suture with a modified Seipser slip knot. The authors compared the surgical time of each technique. All eyes underwent standard full-field electroretinogram at baseline and 8 weeks after surgery. The animals were euthanized and eyes collected for histologic analysis after 70 days (10 weeks) postsurgery. The corneal thickness, corneal endothelial cell counts, specular microscopy parameters, retina cell counts, and electroretinogram parameters were compared between the groups. A two sample t-test for means and a P value of 0.05 were use for assessing statistical differences between measurements. Results. The injection of the nitinol clip was 15 times faster than conventional suturing. There were no statistical differences between the groups for corneal thickness, endothelial cell counts, specular microscopy parameters, retina cell counts, and electroretinogram measurements. Conclusions. The nitinol clip prototype is well tolerated and showed no evidence of toxicity in the short-term. The injectable delivery system was faster and technically less challenging than conventional suture techniques. PMID:22064995

  2. [Surgical fixation of rib fractures with clips and titanium bars (STRATOS System). Preliminary experience].

    PubMed

    Moreno De La Santa Barajas, Pablo; Polo Otero, María Dolores; Delgado Sánchez-Gracián, Carlos; Lozano Gómez, Manuel; Toscano Novella, Alberto; Calatayud Moscoso Del Prado, Julia; Leal Ruiloba, Sonsoles; Choren Durán, Maria L

    2010-09-01

    Rib fractures are very common in closed chest injuries. The majority of these patients suffer significant pain with movement and cough. The purpose of this study is to assess the usefulness of titanium rib bars and clips in stabilising rib fractures. Twenty-two patients with rib fractures were treated with open reduction and internal fixation between 2008 and 2009. Indications for treatment were defined as; 1) Patients with unstable chest (13 patients), 2) Patients with pain or instability due to rib fractures (6 patients), and 3) Significant traumatic deformities of the chest wall (3 patients). Age, traumatic mechanism, chest and associated injuries, surgical data, complications and follow-up were prospectively analysed. The surgical technique is described. The majority of patients were extubated immediately after surgery. All patients with pain or instability showed a subjective improvement or disappearance of pain after the surgery. Four patients had a wound infection which had to be drained. After 3 months, 55% of the patients had returned to work or normal life. The results in each group are described. Open reduction with internal fixation of rib fractures is a good alternative. The use of titanium rib bars and clips give good clinical results, are easy to apply and have few complications. Copyright © 2010 AEC. Published by Elsevier Espana. All rights reserved.

  3. Intracranial Aneurysms of Neuro-Ophthalmologic Relevance.

    PubMed

    Micieli, Jonathan A; Newman, Nancy J; Barrow, Daniel L; Biousse, Valérie

    2017-12-01

    Intracranial saccular aneurysms are acquired lesions that often present with neuro-ophthalmologic symptoms and signs. Recent advances in neurosurgical techniques, endovascular treatments, and neurocritical care have improved the optimal management of symptomatic unruptured aneurysms, but whether the chosen treatment has an impact on neuro-ophthalmologic outcomes remains debated. A review of the literature focused on neuro-ophthalmic manifestations and treatment of intracranial aneurysms with specific relevance to neuro-ophthalmologic outcomes was conducted using Ovid MEDLINE and EMBASE databases. Cavernous sinus aneurysms were not included in this review. Surgical clipping vs endovascular coiling for aneurysms causing third nerve palsies was compared in 13 retrospective studies representing 447 patients. Complete recovery was achieved in 78% of surgical patients compared with 44% of patients treated with endovascular coiling. However, the complication rate, hospital costs, and days spent in intensive care were reported as higher in surgically treated patients. Retrospective reviews of surgical clipping and endovascular coiling for all ocular motor nerve palsies (third, fourth, or sixth cranial nerves) revealed similar results of complete resolution in 76% and 49%, respectively. Improvement in visual deficits related to aneurysmal compression of the anterior visual pathways was also better among patients treated with clipping than with coiling. The time to treatment from onset of visual symptoms was a predictive factor of visual recovery in several studies. Few reports have specifically assessed the improvement of visual deficits after treatment with flow diverters. Decisions regarding the choice of therapy for intracranial aneurysms causing neuro-ophthalmologic signs ideally should be made at high-volume centers with access to both surgical and endovascular treatments. The status of the patient, location of the aneurysm, and experience of the treating physicians are important factors to consider. Although a higher rate of visual recovery was reported with neurosurgical clipping, this must be weighed against the potentially longer intensive care stays and increased early morbidity.

  4. Teflon Implants Versus Titanium Implants in Stapes Surgery.

    PubMed

    Bansal, Mohan

    2016-03-01

    Otosclerosis is the most common cause of bilateral gradually progressive conductive hearing loss with normal tympanic membrane and Eustachian tube. Otosclerosis surgical treatment is one of the most gratifying operations in Otorhinolaryngology. It is not only the surgical techniques but also the prosthesis which are evolving in the attempt of providing best hearing results. Teflon piston is the most commonly employed prosthesis in stapes surgery. Titanium pistons are relatively the new development in the evolution of stapes prosthesis. The aim of this review article is to know and compare the surgical technicalities and postoperative outcomes including hearing improvement after the use of Teflon and titanium stapes piston. The adverse reactions occurred during follow-up were taken into consideration. The data in this article are supported by a Medline search. The use of both the prosthesis gave good results in cases of otosclerosis. The placement of titanium soft clip design was found easier than the earlier àWengen design of clip piston.

  5. Iatrogenic Subtotal Stenosis of the Right Subclavian Artery Treated With Percutaneous Transluminal Angioplasty

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smeenk, Robert M., E-mail: r.m.smeenk@asz.nl; Kock, Mark C. J. M.; Elgersma, Otto E. H.

    2011-02-15

    This report describes a rare vascular complication of surgical placement of a marking clip and a possible approach to problem solving. A 55-year-old patient presented with loss of sensation in the fingers and loss of peripheral pulsations in the right arm 4 days after right upper lobectomy for a pT2N1 moderately differentiated adenocarcinoma of the lung. Duplex examination and computed tomography were performed the same day and showed a subtotal stenosis of the right subclavian artery, which was caused by the surgical placement of a metal clip to mark the surgical boundary. Selective angiography was subsequently performed. Percutaneous transluminal angioplastymore » (PTA) successfully dilated the stenosis and pushed the clip off. Flow in the right subclavian artery (RSA) was completely restored as were neurology and peripheral pulses. In conclusion, arterial stenosis by a surgical (marking) clip may be feasibly treated with PTA.« less

  6. Endoscopic closure of duodenal perforations by using an over-the-scope clip: a randomized, controlled porcine study.

    PubMed

    von Renteln, Daniel; Rudolph, Hans-Ulrich; Schmidt, Arthur; Vassiliou, Melina C; Caca, Karel

    2010-01-01

    Duodenal perforations during diagnostic upper endoscopy are rare; however, when therapeutic techniques are performed, the reported incidence is as great as 2.8%. Surgical repair is usually mandated, but it is associated with significant morbidity and mortality. To compare closure of duodenal perforations by using an over-the-scope clip (OTSC) with a surgical closure. Randomized, controlled animal study. Animal facility laboratory. Domestic pigs (24 females). Large (10-mm) duodenal perforations were created by using an endoscopic needle-knife. The animals were randomly assigned to either open surgical repair (n=12) or endoscopic closure by using the OTSC system (n=12). Pressurized leak tests were performed during necropsy. One major bleed occurred because of a liver injury during creation of the duodenotomy. Mean time for endoscopic closure was 5 minutes (range, 3-8 min; SD +/- 2). No complications occurred during any of the closure procedures. At necropsy, all OTSC and surgical closures demonstrated complete sealing of duodenotomy sites. Pressurized leak tests demonstrated a mean burst pressure of 166 mm Hg (range, 80-260; SD +/- 65) for OTSC closures and 143 mm Hg (range, 30-300, SD +/- 83) for surgical sutures. Ex vivo intact duodenal specimens exhibited a mean burst pressure of 247 mm Hg (range, 200-300; SD +/- 35), which was significantly higher compared with in vivo OTSC and surgical closures (P < .01). There were no significant differences between burst pressures of OTSC and surgical closures (P = .461). Nonsurvival setting. Endoscopic closure of duodenal perforations by using the OTSC system is comparable with surgical closure in a nonsurvival porcine model. This technique is easy to perform and seems suitable for repairing duodenal perforations. 2010 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  7. 21 CFR 878.4320 - Removable skin clip.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Removable skin clip. 878.4320 Section 878.4320...) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4320 Removable skin clip. (a) Identification. A removable skin clip is a clip-like device intended to connect skin tissues temporarily to aid...

  8. Over the scope clip: technique and expanding clinical applications.

    PubMed

    Singhal, Shashideep; Changela, Kinesh; Papafragkakis, Haris; Anand, Sury; Krishnaiah, Mahesh; Duddempudi, Sushil

    2013-10-01

    Advances in endoscopic and surgical techniques have increased the frequency and complexity of these procedures, and thus, the incidence of associated complications. To describe the use and clinical applications of the Over the Scope Clip (OTSC) system. An English language literature search was conducted using the key words "endoscopy" and "over the scope clip" in order to identify human studies evaluating the application of OTSC from January 2001 to August 2012. The indication, efficacy, complications, and limitations were recorded. Overall success rates of OTSC based on current literature range are in the range of 75% to 100% for closure of iatrogenic gastrointestinal perforations, 38% to 100% for closure of gastrointestinal fistulas, 50% to 100% for anastomotic leaks, and 71% to 100% for bleeding lesions. OTSCs have shown 100% success rates in managing postbariatric surgery weight gain secondary to dilation of the gastrojejunal pouch. OTSC is easy to use with good results, thus decreasing the morbidity and mortality associated with the complications secondary to both diagnostic and therapeutic endoscopy and avoiding surgery in many situations.

  9. Role of over the scope clips in the management of iatrogenic gastrointestinal perforations

    PubMed Central

    Changela, Kinesh; Virk, Muhhamad A; Patel, Niravkumar; Duddempudi, Sushil; Krishnaiah, Mahesh; Anand, Sury

    2014-01-01

    Advances in endoscopic and surgical techniques have increased the frequency and complexity of these procedures and associated complications such as gastrointestinal perforation. With the advancements in the field of gastroenterology, the promising use of an over the scope clips (OTSC) has fulfilled the unmet need for a reliable endoscopic devise in approximation of gastrointestinal perforation. This novel approach has raised the level of confidence in endoscopist in dealing with this serious complication during endoscopy. Here we have shared our experience with OTSC to evaluate its efficacy and safety in managing iatrogenic gastrointestinal perforations during endoscopy. PMID:25170237

  10. Role of over the scope clips in the management of iatrogenic gastrointestinal perforations.

    PubMed

    Changela, Kinesh; Virk, Muhhamad A; Patel, Niravkumar; Duddempudi, Sushil; Krishnaiah, Mahesh; Anand, Sury

    2014-08-28

    Advances in endoscopic and surgical techniques have increased the frequency and complexity of these procedures and associated complications such as gastrointestinal perforation. With the advancements in the field of gastroenterology, the promising use of an over the scope clips (OTSC) has fulfilled the unmet need for a reliable endoscopic devise in approximation of gastrointestinal perforation. This novel approach has raised the level of confidence in endoscopist in dealing with this serious complication during endoscopy. Here we have shared our experience with OTSC to evaluate its efficacy and safety in managing iatrogenic gastrointestinal perforations during endoscopy.

  11. Migrated Hem-o-Lok clips in the ureter: a rare cause of recurrent urinary tract infection.

    PubMed

    Shrivastava, Prashant; Nayak, Brusabhanu; Singh, Prabhjot

    2017-02-15

    Erosion of surgical materials into the adjacent organs following surgical procedures is a rare complication. Migrations of these surgical materials into the urinary tract like pelvicalyceal system, ureter and bladder have been reported following various urological procedures. We present a case of migrated Hem-o-Lok clips into the ureter following a laparoscopic partial nephrectomy for angiomyolipoma of the left kidney presented with recurrent urinary tract infection. The case was managed with ureteroscopic removal of clips. The patient is asymptomatic on last follow-up. 2017 BMJ Publishing Group Ltd.

  12. 21 CFR 882.4215 - Clip rack.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Clip rack. 882.4215 Section 882.4215 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4215 Clip rack. (a) Identification. A clip rack is a...

  13. 21 CFR 882.4150 - Scalp clip.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Scalp clip. 882.4150 Section 882.4150 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4150 Scalp clip. (a) Identification. A scalp clip is a...

  14. 21 CFR 882.4150 - Scalp clip.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Scalp clip. 882.4150 Section 882.4150 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4150 Scalp clip. (a) Identification. A scalp clip is a...

  15. 21 CFR 882.4215 - Clip rack.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Clip rack. 882.4215 Section 882.4215 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4215 Clip rack. (a) Identification. A clip rack is a...

  16. 21 CFR 882.4175 - Aneurysm clip applier.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Aneurysm clip applier. 882.4175 Section 882.4175...) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4175 Aneurysm clip applier. (a) Identification. An aneurysm clip applier is a device used by the surgeon for holding and applying intracranial...

  17. 21 CFR 882.4175 - Aneurysm clip applier.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Aneurysm clip applier. 882.4175 Section 882.4175...) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4175 Aneurysm clip applier. (a) Identification. An aneurysm clip applier is a device used by the surgeon for holding and applying intracranial...

  18. 21 CFR 882.4175 - Aneurysm clip applier.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Aneurysm clip applier. 882.4175 Section 882.4175...) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4175 Aneurysm clip applier. (a) Identification. An aneurysm clip applier is a device used by the surgeon for holding and applying intracranial...

  19. Median Supraorbital Keyhole Approach for Clipping Ruptured Distal Anterior Cerebral Artery Aneurysm: Technical Report with Review of Literature.

    PubMed

    Dhandapani, Sivashanmugam; Sahoo, Sushant Kumar

    2018-04-01

    The minimally invasive approach to distal anterior cerebral artery (DACA) aneurysms has not gained much acceptance due to difficulties associated with the conventional frontal paramedian approach. The more proximal basal interhemispheric approach, however, necessitates extensive dissection of soft tissues. We describe a novel minimally invasive median supraorbital keyhole craniotomy with a basal interhemispheric approach for clipping a ruptured DACA aneurysm. A 62-year-old patient presented with subarachnoid hemorrhage. Computed tomography angiography revealed a DACA aneurysm. The surgical technique involved a keyhole craniotomy made via an eyebrow incision extending between the supraorbital notches, and flush with the anterior cranial fossa. The dura was opened at the anterior part, the falx was cut, an interhemispheric dissection was carried out, adequate proximal control was obtained, and the aneurysm neck was dissected and clipped. A relevant review of the literature was carried out. The patient recovered well, with no residual aneurysm or forehead numbness, with good cosmesis. Compared with the previously described "keyhole unilateral interhemispheric" approaches, our technique has less likelihood of encountering bridging veins; easier cisternal cerebrospinal fluid release, making it feasible even in swollen brain; better proximal vascular control; and trajectory toward the neck rather than dome. The median supraorbital keyhole approach is a minimally invasive technique sufficient for clipping most DACA aneurysms, with easier access, better proximal control, and good cosmesis. Copyright © 2018 Elsevier Inc. All rights reserved.

  20. Preoperative simulation for the planning of microsurgical clipping of intracranial aneurysms.

    PubMed

    Marinho, Paulo; Vermandel, Maximilien; Bourgeois, Philippe; Lejeune, Jean-Paul; Mordon, Serge; Thines, Laurent

    2014-12-01

    The safety and success of intracranial aneurysm (IA) surgery could be improved through the dedicated application of simulation covering the procedure from the 3-dimensional (3D) description of the surgical scene to the visual representation of the clip application. We aimed in this study to validate the technical feasibility and clinical relevance of such a protocol. All patients preoperatively underwent 3D magnetic resonance imaging and 3D computed tomography angiography to build 3D reconstructions of the brain, cerebral arteries, and surrounding cranial bone. These 3D models were segmented and merged using Osirix, a DICOM image processing application. This provided the surgical scene that was subsequently imported into Blender, a modeling platform for 3D animation. Digitized clips and appliers could then be manipulated in the virtual operative environment, allowing the visual simulation of clipping. This simulation protocol was assessed in a series of 10 IAs by 2 neurosurgeons. The protocol was feasible in all patients. The visual similarity between the surgical scene and the operative view was excellent in 100% of the cases, and the identification of the vascular structures was accurate in 90% of the cases. The neurosurgeons found the simulation helpful for planning the surgical approach (ie, the bone flap, cisternal opening, and arterial tree exposure) in 100% of the cases. The correct number of final clip(s) needed was predicted from the simulation in 90% of the cases. The preoperatively expected characteristics of the optimal clip(s) (ie, their number, shape, size, and orientation) were validated during surgery in 80% of the cases. This study confirmed that visual simulation of IA clipping based on the processing of high-resolution 3D imaging can be effective. This is a new and important step toward the development of a more sophisticated integrated simulation platform dedicated to cerebrovascular surgery.

  1. Conventional Surgery for Early and Late Symptomatic Mitral Valve Stenosis After MitraClip® Intervention: An Institutional Experience With Four Consecutive Patients.

    PubMed

    Alozie, Anthony; Paranskaya, Liliya; Westphal, Bernd; Kaminski, Alexander; Steinhoff, Gustav; Sherif, Mohammad; Ince, Hüseyin; Öner, Alper

    2017-12-01

    Surgical mitral valve repair is the gold standard for treatment of mitral regurgitation. Recently, the transcatheter treatment of mitral regurgitation with the MitraClip ® device (Abbot Vascular Structural Heart, Menlo Park, CA) has demonstrated promising results in treating patients not amenable for surgical correction of mitral valve regurgitation. Most patients reported in the literature requiring surgical bailout after MitraClip treatment presented with residual or recurrent mitral valve regurgitation. Mitral valve stenosis after MitraClip treatment has been rarely reported. From February 2010 to December 2014, four patients out of 165 patients who underwent MitraClip therapy developed symptomatic mitral valve stenosis (2.4%) and needed surgical correction. Data of the four patients were reviewed retrospectively. Follow-up data were obtained from each patient's general practitioner/cardiologist by phone calls and facsimile and were complete in all patients. All four patients were treated with ≥ 2 MitraClip (MC) devices during their initial presentation. All four patients underwent MV replacement with a tissue valve. The postoperative course was uneventful and there was no 30-day mortality. At 6-month follow-up, all patients were alive and in NYHA class I-III. Placement of multiple clip devices may lead to slightly elevated transmitral gradients. This may not necessarily interpret into symptomatic mitral stenosis. However, in some cases this is possible. Caution should be exercised at this phase of the learning curve of the percutaneous MC treatment, especially in use of multiple MC devices. Copyright © 2017 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.

  2. Surgical decision making in a teaching hospital: a linguistic analysis.

    PubMed

    Bezemer, Jeff; Murtagh, Ged; Cope, Alexandra; Kneebone, Roger

    2016-10-01

    The aim of the study was to gain insight in the involvement of non-operating surgeons in intraoperative surgical decision making at a teaching hospital. The decision to proceed to clip and cut the cystic duct during laparoscopic cholecystectomy was investigated through direct observation of team work. Eleven laparoscopic cholecystectomies performed by consultant surgeons and specialty trainees at a London teaching hospital were audio and video recorded. Talk among the surgical team was transcribed and subjected to linguistic analysis, in conjunction with observational analysis of the video material, sequentially marking the unfolding operation. Two components of decision making were identified, participation and rationalization. Participation refers to the degree to which agreement was sought within the surgical team prior to clipping the cystic duct. Rationalization refers to the degree to which the evidential grounds for clipping and cutting were verbalized. The decision to clip and cut the cystic duct was jointly made by members of the surgical team, rather than a solitary surgeon in the majority of cases, involving verbal explication of clinical reasoning and verbal agreement. The extent of joint decision making appears to have been mitigated by two factors: trainee's level of training and duration of the case. © 2014 Royal Australasian College of Surgeons.

  3. 21 CFR 882.4200 - Clip removal instrument.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Clip removal instrument. 882.4200 Section 882.4200 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4200 Clip removal instrument. (a...

  4. 21 CFR 882.4175 - Aneurysm clip applier.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Aneurysm clip applier. 882.4175 Section 882.4175 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4175 Aneurysm clip applier. (a...

  5. 21 CFR 882.4190 - Clip forming/cutting instrument.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Clip forming/cutting instrument. 882.4190 Section 882.4190 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4190 Clip forming...

  6. 21 CFR 882.4175 - Aneurysm clip applier.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Aneurysm clip applier. 882.4175 Section 882.4175 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4175 Aneurysm clip applier. (a...

  7. 21 CFR 882.4200 - Clip removal instrument.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Clip removal instrument. 882.4200 Section 882.4200 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4200 Clip removal instrument. (a...

  8. 21 CFR 878.4300 - Implantable clip.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Implantable clip. 878.4300 Section 878.4300 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4300 Implantable clip. (a...

  9. 21 CFR 878.4300 - Implantable clip.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Implantable clip. 878.4300 Section 878.4300 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4300 Implantable clip. (a...

  10. 21 CFR 878.4300 - Implantable clip.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Implantable clip. 878.4300 Section 878.4300 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4300 Implantable clip. (a...

  11. 21 CFR 878.4300 - Implantable clip.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Implantable clip. 878.4300 Section 878.4300 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4300 Implantable clip. (a...

  12. 21 CFR 878.4300 - Implantable clip.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Implantable clip. 878.4300 Section 878.4300 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4300 Implantable clip. (a...

  13. 21 CFR 878.4320 - Removable skin clip.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Removable skin clip. 878.4320 Section 878.4320 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4320 Removable skin clip. (a...

  14. 21 CFR 878.4320 - Removable skin clip.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Removable skin clip. 878.4320 Section 878.4320 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4320 Removable skin clip. (a...

  15. 21 CFR 878.4320 - Removable skin clip.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Removable skin clip. 878.4320 Section 878.4320 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4320 Removable skin clip. (a...

  16. 21 CFR 878.4320 - Removable skin clip.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Removable skin clip. 878.4320 Section 878.4320 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4320 Removable skin clip. (a...

  17. Retreatment of Recurrent Internal Carotid-Posterior Communicating Artery Aneurysm after Coil Embolization

    PubMed Central

    TOYOTA, Shingo; TAKI, Takuyu; WAKAYAMA, Akatsuki; YOSHIMINE, Toshiki

    2015-01-01

    Internal carotid-posterior communicating artery (IC-PC) aneurysms account for more than 20% of all intracranial aneurysms. As a result of the increase in coiling, there has also been an increase in recurrent IC-PC aneurysms after coiling. We present our experience of 10 recurrent IC-PC aneurysms after coiling that were retreated using surgical or endovascular techniques in order to discuss the choice of treatment and the points of clipping without removal of coils. From 2007 to 2014, 10 recurrent IC-PC aneurysms after coiling were retreated. When the previous frames covered the aneurysms all around or almost around except a part of the neck, coiling was chosen. In other cases, clipping was chosen. Clipping was attempted without removal of coils when it was technically feasible. Among the 10 IC-PC aneurysms retreated, 3 were retreated with coiling and 7 were retreated with clipping. In all three cases retreated with coiling, almost complete occlusion was accomplished. In the seven cases retreated with clipping, coil extrusion was observed during surgery in six cases. In most of them, it was necessary to dissect strong adhesions around the coiled aneurysms and to utilize temporary occlusion of the internal carotid artery. In all seven cases, neck clipping was accomplished without the removal of coils. There were no neurological complications in any cases. The management of recurrent lesions of embolized IC-PC aneurysms requires appropriate choice of treatment using both coiling and clipping. Clipping, especially without the removal of coils, plays an important role in safe treatment. PMID:26437796

  18. Retreatment of Recurrent Internal Carotid-Posterior Communicating Artery Aneurysm after Coil Embolization.

    PubMed

    Toyota, Shingo; Taki, Takuyu; Wakayama, Akatsuki; Yoshimine, Toshiki

    2015-01-01

    Internal carotid-posterior communicating artery (IC-PC) aneurysms account for more than 20% of all intracranial aneurysms. As a result of the increase in coiling, there has also been an increase in recurrent IC-PC aneurysms after coiling. We present our experience of 10 recurrent IC-PC aneurysms after coiling that were retreated using surgical or endovascular techniques in order to discuss the choice of treatment and the points of clipping without removal of coils. From 2007 to 2014, 10 recurrent IC-PC aneurysms after coiling were retreated. When the previous frames covered the aneurysms all around or almost around except a part of the neck, coiling was chosen. In other cases, clipping was chosen. Clipping was attempted without removal of coils when it was technically feasible. Among the 10 IC-PC aneurysms retreated, 3 were retreated with coiling and 7 were retreated with clipping. In all three cases retreated with coiling, almost complete occlusion was accomplished. In the seven cases retreated with clipping, coil extrusion was observed during surgery in six cases. In most of them, it was necessary to dissect strong adhesions around the coiled aneurysms and to utilize temporary occlusion of the internal carotid artery. In all seven cases, neck clipping was accomplished without the removal of coils. There were no neurological complications in any cases. The management of recurrent lesions of embolized IC-PC aneurysms requires appropriate choice of treatment using both coiling and clipping. Clipping, especially without the removal of coils, plays an important role in safe treatment.

  19. [The comparison of efficacy of female sterilization by modified Uchida technique and silver clips in China].

    PubMed

    Qiu, Hong-yan; Zou, Yan; Li, Li; Liang, Hong; Zhang, Hong-yan; Wu, Shang-chun

    2011-02-01

    To compare efficacy of female sterilization by modified Uchida technique and silver clips and to evaluate the influence on operation procedure and clinical effect with or without surgery training of service providers. A comparative, multicenter clinical trial was performed in 18 county and township-level service centers. Totally 2198 women underwent sterilization from these 18 study center were divided into 1116 women sterilized by modified Uchida technique and 1082 women by silver clips. Those 18 centers were classified into 9 training groups which provide surgical skills of sterilization and other contents and 9 non training groups. Clinical documents of sterilization were recorded. All women were follow-up at 3, 6 and 12 months after surgery. There were no complications during surgery by both sterilization. The failure rate was 2.03% (22/1082) in silver clip method and the mean operative time were (12.4 ± 6.4) minutes in training group and (14.4 ± 8.1) minutes in non training group. In modified Uchida method, the failure rate was 0.18% (2/1116) and the mean operative time were (16.2 ± 4.9) minutes in training group and (19.0 ± 8.6) minutes in non training group. The mean operative time between two groups reached statistical difference (all P < 0.05). Total ended rate in modified Uchida technique were 2.2/hundred women year in training group and 2.5/hundred women year in non training group, and the rate of silver slips were 3.9/hundred women year and 4.8/hundred women year, which did not show significant difference (all P > 0.05). There was no significant difference in acceptability and side effects of all women between two methods (P > 0.05). The training of service providers could influence acceptability of women (P < 0.05). Clinical efficacy was not influenced by those two methods. The operative time and acceptability were improved by training surgeons in silver clips method.

  20. Assessment of incomplete clipping of aneurysms intraoperatively by a near-infrared indocyanine green-video angiography (Niicg-Va) integrated microscope.

    PubMed

    Imizu, S; Kato, Y; Sangli, A; Oguri, D; Sano, H

    2008-08-01

    The objective of this article was to assess the clinical use and the completeness of clipping with total occlusion of the aneurysmal lumen, real-time assessment of vascular patency in the parent, branching and perforating vessels, intraoperative assessment of blood flow, image quality, spatial resolution and clinical value in difficult aneurysms using near infrared indocyanine green video angiography integrated on to an operative Pentero neurosurgical microscope (Carl Zeiss, Oberkochen Germany). Thirteen patients with aneurysms were operated upon. An infrared camera with near infrared technology was adapted on to the OPMI Pentero microscope with a special filter and infrared excitation light to illuminate the operating field which was designed to allow passage of the near infrared light required for excitation of indocyanine green (ICG) which was used as the intravascular marker. The intravascular fluorescence was imaged with a video camera attached to the microscope. ICG fluorescence (700-850 nm) from a modified microscope light source on to the surgical field and passage of ICG fluorescence (780-950 nm) from the surgical field, back into the optical path of the microscope was used to detect the completeness of aneurysmal clipping Incomplete clipping in three patients (1 female and 2 males) with unruptured complicated aneurysms was detected using indocyanine green video angiography. There were no adverse effects after injection of indocyanine green. The completeness of clipping was inadequately detected by Doppler ultrasound miniprobe and rigid endoscopy and was thus complemented by indocyanine green video angiography. The operative microscope-integrated ICG video angiography as a new intraoperative method for detecting vascular flow, was found to be quick, reliable, cost-effective and possibly a substitute or adjunct for Doppler ultrasonography or intraoperative DSA, which is presently the gold standard. The simplicity of the method, the speed with which the investigation can be performed, the quality of the images, and the outcome of surgical procedures have all reduced the need for angiography. This technique may be useful during routine aneurysm surgery as an independent form of angiography and/or as an adjunct to intraoperative or postoperative DSA.

  1. [Hurt eczematiforme column (chronicle) of the breast after implementation of a surgical clip].

    PubMed

    Motton, S; Gardinal, I; Soulé-Tholy, M; Viraben, R; Hoff, J; Leguevaque, P

    2011-04-01

    We report a case of atopic dermatitis in relation with a surgical titanium clip. Such a complication has only been reported once in the literature. We advocate to ask the patients about query atopic manifestations especially contact dermatitis to metal before any procedure involving metallic implants. Copyright © 2010 Elsevier Masson SAS. All rights reserved.

  2. Advances in open microsurgery for cerebral aneurysms.

    PubMed

    Davies, Jason M; Lawton, Michael T

    2014-02-01

    Endovascular techniques introduced strong extrinsic forces that provoked reactive changes in aneurysm surgery. Microsurgery has become less invasive, more appealing to patients, lower risk, and efficacious for complex aneurysms, particularly those unfavorable for or failing endovascular therapy. To review specific advances in open microsurgery for aneurysms. A university-based, single-surgeon practice was examined for the use of minimally invasive craniotomies, surgical management of recurrence after coiling, the use of intracranial-intracranial bypass techniques, and cerebrovascular volume-outcome relationships. The mini-pterional, lateral supraorbital, and orbital-pterional craniotomies are minimally invasive alternatives to standard craniotomies. Mini-pterional and lateral supraorbital craniotomies were used in one-fourth of unruptured patients, increasing from 22% to 28%, whereas 15% of patients underwent orbital-pterional craniotomies and trended upward from 11% to 20%. Seventy-four patients were treated for coil recurrences (2.3% of all aneurysms) with direct clip occlusion (77%), clip occlusion after coil extraction (7%), or parent artery occlusion with bypass (16%). Intracranial-intracranial bypass (in situ bypass, reimplantation, reanastomosis, and intracranial grafts) transformed the management of giant aneurysms and made the surgical treatment of posterior inferior cerebellar artery aneurysms competitive with endovascular therapy. Centralization maximized the volume-outcome relationships observed with clipping. Aneurysm microsurgery has embraced minimalism, tailoring the exposure to the patient's anatomy with the smallest possible craniotomy that provides adequate exposure. The development of intracranial-intracranial bypasses is an important advancement that makes microsurgery a competitive option for complex and recurrent aneurysms. Trends toward centralizing aneurysm surgery in tertiary centers optimize results achievable with open microsurgery.

  3. A cadaveric study of the endoscopic endonasal transclival approach to the basilar artery.

    PubMed

    Lai, Leon T; Morgan, Michael K; Chin, David C W; Snidvongs, Kornkiat; Huang, June X Z; Malek, Joanne; Lam, Matthew; McLachlan, Rohan; Harvey, Richard J

    2013-04-01

    The anterior transclival route to basilar artery aneurysms is not widely performed. The objective of this study was to carry out a feasibility assessment of the transclival approach to basilar aneurysms with advanced endonasal techniques on 11 cadaver heads. Clival dura was exposed from the sella to the foramen magnum between the paraclival segments of the internal carotid arteries (ICA) laterally. An inverted dural "U" flap was reflected inferiorly to expose the basilar artery. The maximal dimensions from operative measurements were recorded. Surgical manoeuvrability of multiple instruments and the proficiency to place proximal and distal vascular clips were evaluated. The mean operative depth (± standard deviation), measured from the anterior choanae to the basilar artery, was 110±6mm. The lateral corridors were limited distally by the medial pterygoids (mean width 21±2mm) and paraclival ICA (mean width 20±2mm). The mean transclival craniectomy dimensions were 19±2mm (width) and 23±4mm (height). Exposure of the basilar-anterior inferior cerebellar artery junction, superior cerebellar artery, and the basilar caput were possible in 100%, 91%, and 64% of instances, respectively. Placements of proximal and distal aneurysm clips were achieved in all instances. Based on our findings, the transclival endoscopic endonasal surgery approach provides excellent visualisation of the basilar artery. Clip application and manoeuvrability of instruments was considered adequate for basilar aneurysm surgery. Surgical skills and instrumentation to control significant haemorrhage can potentially limit the clinical applicability of this technique. Crown Copyright © 2012. Published by Elsevier Ltd. All rights reserved.

  4. Oculomotor nerve palsy by posterior communicating artery aneurysms: influence of surgical strategy on recovery.

    PubMed

    Güresir, Erdem; Schuss, Patrick; Seifert, Volker; Vatter, Hartmut

    2012-11-01

    Resolution of oculomotor nerve palsy (ONP) after clipping of posterior communicating artery (PCoA) aneurysms has been well documented. However, whether additional decompression of the oculomotor nerve via aneurysm sac dissection or resection is superior to pure aneurysm clipping is the subject of much debate. Therefore, the objective in the present investigation was to analyze the influence of surgical strategy--specifically, clipping with or without aneurysm dissection--on ONP resolution. Between June 1999 and December 2010, 18 consecutive patients with ruptured and unruptured PCoA aneurysms causing ONP were treated at the authors' institution. Oculomotor nerve palsy was evaluated on admission and at follow-up. The electronic database MEDLINE was searched for additional data in published studies of PCoA aneurysms causing ONP. Two reviewers independently extracted data. Overall, 8 studies from the literature review and 6 patients in the current series (121 PCoA aneurysms) met the study inclusion criteria. Ninety-four aneurysms were treated with simple aneurysm neck clipping and 27 with clipping plus aneurysm sac decompression. The surgical strategy, simple aneurysm neck clipping versus clipping plus oculomotor nerve decompression, had no effect on full ONP resolution on univariate (p = 0.5) and multivariate analyses. On multivariate analysis, patients with incomplete ONP at admission were more likely to have full resolution of the palsy than were those with complete ONP at admission (p = 0.03, OR = 4.2, 95% CI 1.1-16). Data in the present study indicated that ONP caused by PCoA aneurysms improves after clipping without and with oculomotor nerve decompression. The resolution of ONP is inversely associated with the initial severity of ONP.

  5. Epicardial clip occlusion of the left atrial appendage during cardiac surgery provides optimal surgical results and long-term stability.

    PubMed

    Kurfirst, Vojtech; Mokrácek, Aleš; Canádyová, Júlia; Frána, Radim; Zeman, Petr

    2017-07-01

    Occlusion of the left atrial appendage (LAA) has become an integral and important part of the surgical treatment of atrial fibrillation. Different methods of surgical occlusion of the LAA have been associated with varying levels of short- and long-term success for closure. The purpose of this study was to evaluate long-term results of epicardial placement and endocardial occlusion in patients undergoing cardiac operative procedures. A total of 101 patients (average age 65.7 years) undergoing cardiac operative procedures with the epicardial AtriClip Exclusion System of the LAA were enrolled in the study. The AtriClip was placed via a sternotomy or a thoracotomy or from a thoracoscopic approach. Postoperative variables, such as thromboembolic events, clip stability and endocardial leakage around the device, were examined by transoesophageal echocardiography (TEE) and/or computed tomography. Perioperative clip implantation was achieved in 98% of patients. TEE and/or computed tomography conducted during the follow-up period, comprising 1873 patient-months with a mean duration of 18 ± 11 months, revealed no clip migration, no leakage around the device and no clot formation near the remnant cul-de-sac. During the follow-up period, 4 of the cardiac patients experienced transitory ischaemic attacks, whereas no patient experienced a cerebrovascular attack. The Epicardial AtriClip Exclusion System of the LAA appears to be a feasable and safe operative method with a high success rate. Long-term follow-up confirmed clip stability, complete occlussion of the LAA and absence of any atrial fibrilation-related thromboembolic events. These results need to be confirmed by a larger, multicentre study. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  6. Surgical gesture classification from video and kinematic data.

    PubMed

    Zappella, Luca; Béjar, Benjamín; Hager, Gregory; Vidal, René

    2013-10-01

    Much of the existing work on automatic classification of gestures and skill in robotic surgery is based on dynamic cues (e.g., time to completion, speed, forces, torque) or kinematic data (e.g., robot trajectories and velocities). While videos could be equally or more discriminative (e.g., videos contain semantic information not present in kinematic data), they are typically not used because of the difficulties associated with automatic video interpretation. In this paper, we propose several methods for automatic surgical gesture classification from video data. We assume that the video of a surgical task (e.g., suturing) has been segmented into video clips corresponding to a single gesture (e.g., grabbing the needle, passing the needle) and propose three methods to classify the gesture of each video clip. In the first one, we model each video clip as the output of a linear dynamical system (LDS) and use metrics in the space of LDSs to classify new video clips. In the second one, we use spatio-temporal features extracted from each video clip to learn a dictionary of spatio-temporal words, and use a bag-of-features (BoF) approach to classify new video clips. In the third one, we use multiple kernel learning (MKL) to combine the LDS and BoF approaches. Since the LDS approach is also applicable to kinematic data, we also use MKL to combine both types of data in order to exploit their complementarity. Our experiments on a typical surgical training setup show that methods based on video data perform equally well, if not better, than state-of-the-art approaches based on kinematic data. In turn, the combination of both kinematic and video data outperforms any other algorithm based on one type of data alone. Copyright © 2013 Elsevier B.V. All rights reserved.

  7. Treatment of Recurrent Intracranial Aneurysms After Clipping: A Report of 23 Cases and a Review of the Literature.

    PubMed

    Hokari, Masaaki; Kazumara, Ken; Nakayama, Naoki; Ushikoshi, Satoshi; Sugiyama, Taku; Asaoka, Katsunori; Uchida, Kazuki; Shimbo, Daisuke; Itamoto, Koji; Yokoyama, Yuka; Isobe, Masanori; Imai, Tetsuaki; Osanai, Toshiya; Houkin, Kiyohiro

    2016-08-01

    There are no established treatment strategies for aneurysms that recur after clipping. In this study, we present cases of patients who experienced recurrent aneurysms after clipping and subsequently underwent surgical intervention. Between 2004 and 2015, we surgically treated 23 aneurysms that recurred at a previously clipped site. Patient characteristics and clinical history were retrospectively reviewed. Patients included 19 women and 4 men 45-81 years old. Aneurysms recurred 3-31 years (mean, 15.4 years) after the initial operation. For 18 cases, the first clinical presentation was a subarachnoid hemorrhage; aneurysms were incidentally diagnosed in 5 patients. Aneurysm locations were as follows: 9 on the internal carotid artery; 4 on the middle cerebral artery; 7 on the anterior communicating artery; 2 on the distal anterior cerebral artery; and 1 on the basilar artery. The reasons for retreatment included subarachnoid hemorrhage (n = 9) and aneurysm regrowth detected on follow-up examinations (n = 14). Endovascular treatment was performed in 10 cases, and direct surgery was performed in 13 cases (clipping in 8, clipping or trapping with bypass in 5). Various complex vascular reconstructions, including high-flow bypass and intracranial-intracranial in situ bypass, were performed for recurrent aneurysms. In our experience, coil embolization is a safe and effective procedure for treating recurrent aneurysms. When cases are unsuitable for coil embolization, surgical treatment often requires neurosurgeons not only to overcome the general technical difficulty of reoperative clipping but also to perform challenging vascular reconstruction. Copyright © 2016. Published by Elsevier Inc.

  8. SU-E-J-64: Feasibility Study of Surgical Clips for Fiducial Tracking in CyberKnife System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, H; Yoon, J; Lee, E

    Purpose: To investigate the ability of CyberKnife to track surgical clips used as fiducial markers. Methods: The Octavius 1000SRS detector and solid water (RW3) slab phantom were used with motion platform to evaluate the study. The RW3 slab phantom was set up to measure the dose distribution from coronal plane. It consists of 9 plates and the thickness of each plate is 10mm. Among them, one plate was attached with 3 surgical clips, which are orthogonally positioned on outer region of array. The length of attached clip was represented as 1cm on planning CT. The clip plate was placed onmore » the 1000SRS detector and 3 slabs were stacked up on the plate to build the measuring depth. Below the detector, 5 slabs were set. The two-axis motion platform was programmed with 1D sinusoidal movement (20mm peak-to-peak, 3s period) toward superior/inferior and left/right directions to simulate target motion. During delivery, two clips were extracted by two X-ray imagers, which led to translational error correction only. Synchrony was also used for dynamic tracking. After the irradiation, the measured dose distribution of coronal plane was compared with the planar dose distribution calculated by the CyberKnife treatment planning system (Multiplan) for cross verification. The results were assessed by comparing the absolute Gamma (γ) index. Results: The dose distributions measured by the 1000SRS detector were in good agreements with those calculated by Multiplan. In the dosimetric comparison using γ-function criteria based on the distance-to-agreement of 3mm and the local dose difference of 3%, the passing rate with γ- parameter ≤1 was 91% in coronal plane. Conclusion: The surgical clips can be considered as new fiducials for robotic radiosurgery delivery by considering the target margin with less than 5mm.« less

  9. Predicting Factors of Chronic Subdural Hematoma Following Surgical Clipping in Unruptured and Ruptured Intracranial Aneurysm.

    PubMed

    Kwon, Min-Yong; Kim, Chang-Hyun; Lee, Chang-Young

    2016-09-01

    The aim of this study is to analyze the differences in the incidence, predicting factors, and clinical course of chronic subdural hematoma (CSDH) following surgical clipping between unruptured (UIA) and ruptured intracranial aneurysm (RIA). We conducted a retrospective analysis of 752 patients (UIA : 368 and RIA : 384) who underwent surgical clipping during 8 years. The incidence and predicting factors of CSDH development in the UIA and RIA were compared according to medical records and radiological data. The incidence of postoperative CSDH was higher in the UIA (10.9%) than in the RIA (3.1%) (p=0.000). In multivariate analysis, a high Hounsfield (HF) unit (blood clots) for subdural fluid collection (SFC), persistence of SFC ≥5 mm and male sex in the UIA and A high HF unit for SFC and SFC ≥5 mm without progression to hydrocephalus in the RIA were identified as the independent predicting factors for CSDH development (p<0.05). There were differences in the incidence and predicting factors for CSDH following surgical clipping between UIA and RIA. Blood clots in the subdural space and persistence of SFC ≥5 mm were predicting factors in both UIA and RIA. However, progression to hydrocephalus may have in part contributed to low CSDH development in the RIA. We suggest that cleaning of blood clots in the subdural space and efforts to minimize SFC ≥5 mm at the end of surgery is helpful to prevent CSDH following aneurysmal clipping.

  10. Supraorbital Keyhole Craniotomy for Basilar Artery Aneurysms: Accounting for the "Cliff" Effect.

    PubMed

    Stamates, Melissa M; Wong, Andrew K; Bhansali, Anita; Wong, Ricky H

    2017-04-01

    Treatment of basilar artery aneurysms is challenging. While endovascular techniques have dominated, there still remain circumstances where open surgical clipping is required or preferred. Minimally invasive "keyhole" approaches are being used more frequently to provide the durability of surgical clipping with a lower morbidity profile; however, careful patient selection is required. The supraorbital "keyhole" approach has been described for the treatment of basilar artery aneurysms, but careful assessment of the basilar exposure is necessary to ensure proper visualization of the aneurysm and ability to obtain proximal vascular control. Various methods of estimating the basilar artery exposure in this approach have been described, including the anterior skull base line and the posterior clinoid line, but both are unreliable and inaccurate. To propose a new method, the orbital roof-dorsum line, to simply and accurately predict the basilar artery exposure. CT angiograms for 20 consecutive unique patients were analyzed to obtain the anterior skull base line, posterior clinoid line, and the orbital roof-dorsum line. CT angiograms were then loaded onto a Stealth neuronavigation system (Medtronic, Minneapolis, Minnesota) to obtain "true" visualization lengths. A case illustration is presented. Pairwise comparison tests demonstrated that both the anterior skull base and the posterior clinoid estimation lines differed significantly from the "true"  value ( P < .0001). Our orbital roof-dorsum estimation provided results that accurately predicted the "true" value ( P = .71). The orbital roof-dorsum line provides a simple and reliable method of estimating basilar artery exposure and should be used whenever considering patients for surgical clipping by this approach. Copyright © 2017 by the Congress of Neurological Surgeons

  11. Microsurgical training on an in vitro chicken wing infusion model.

    PubMed

    Olabe, Jon; Olabe, Javier

    2009-12-01

    Microneurovascular anastomosis and aneurysm clipping require extensive training before mastering the technique and are a surgical challenge. We developed the "infused chicken wing method" to provide a simple but realistic training method minimizing animal use and need for special facilities for animal care and anesthesia. Fresh chicken wings were used in this model. The main brachial artery was cannulated, and water was infused at 140 mm Hg followed by anatomical neurovascular dissection. Multiple microsurgical training exercises were performed under microscope vision including terminoterminal, lateroterminal, laterolateral vascular anastomosis, and nerve anastomosis. Different complexity aneurysms were created using venous patches, clipping, rupture, and vascular reconstruction techniques were performed. This novel training model is inexpensive, easily obtainable, and no live animals are required. The diameter and characteristics of arteries and veins used are similar to those of the human brain. Great microsurgical technique progress may be obtained. The infused chicken wing artery model presents a realistic microvascular training method. It is inexpensive and easy to set up. Such simplicity provides the adequate environment for developing microsurgical technique. Copyright 2009 Elsevier Inc. All rights reserved.

  12. Emerging Transcatheter Options for Tricuspid Regurgitation

    PubMed Central

    Kalra, Ankur; Uberoi, Angad S.; Latib, Azeem; Khera, Sahil; Little, Stephen H.; Bhatt, Deepak L.; Reardon, Michael J.; Kleiman, Neal S.; Barker, Colin M.

    2017-01-01

    Tricuspid regurgitation (TR) presents as either primary valve pathology or secondary to pulmonary or left-sided heart disease. Severe TR portends a worse prognosis independent of age, right ventricular size and function, severe left ventricular dysfunction, and increased pulmonary arterial pressures. Surgical treatment for TR has mostly been limited to patients undergoing mitral valve repair since those at high surgical risk are not candidates for traditional TR surgery. For these patients, minimally invasive techniques could be of great benefit, yet these techniques have been slow to develop because of the various anatomic and physiological aspects of the tricuspid valve apparatus. Several promising new techniques are currently undergoing clinical investigation, including caval valve implantation, percutaneous tricuspid annuloplasty techniques (Trialign, TriCinch, Cardioband), edge-to-edge repair with the MitraClip system, the FORMA device, and the GATE tricuspid Atrioventricular Valved Stent. Further evaluation of their safety and long-term efficacy is warranted prior to commercial approval and widespread adoption. PMID:29743996

  13. The Use of Harmonic Scalpel for Free Flap Dissection in Head and Neck Reconstructive Surgery

    PubMed Central

    Albert, Sebastien; Guedon, Charles; Halimi, Caroline; Cristofari, Jean Pierre; Barry, Beatrix

    2012-01-01

    Surgeons conventionally use electrocautery dissection and surgical clip appliers to harvest free flaps. The ultrasonic Harmonic Scalpel is a new surgical instrument that provides high-quality dissection and hemostasis and minimizes tissue injury. The aim of this study was to evaluate the effectiveness and advantages of the ultrasonic Harmonic Scalpel compared to conventional surgical instruments in free flap surgery. This prospective study included 20 patients who underwent head and neck reconstructive surgery between March 2009 and May 2010. A forearm free flap was used for reconstruction in 12 patients, and a fibular flap was used in 8 patients. In half of the patients, electrocautery and surgical clips were used for free flap harvesting (the EC group), and in the other half of the patients, ultrasonic dissection was performed using the Harmonic Scalpel (the HS group). The following parameters were significantly lower in the HS group compared to the EC group: the operative time of flap dissection (35% lower in the HS group), blood loss, number of surgical clips and cost of surgical materials. This study demonstrated the effectiveness of the Harmonic Scalpel in forearm and fibular free flap dissections that may be extended to other free flaps. PMID:22693666

  14. Real-time surgery simulation of intracranial aneurysm clipping with patient-specific geometries and haptic feedback

    NASA Astrophysics Data System (ADS)

    Fenz, Wolfgang; Dirnberger, Johannes

    2015-03-01

    Providing suitable training for aspiring neurosurgeons is becoming more and more problematic. The increasing popularity of the endovascular treatment of intracranial aneurysms leads to a lack of simple surgical situations for clipping operations, leaving mainly the complex cases, which present even experienced surgeons with a challenge. To alleviate this situation, we have developed a training simulator with haptic interaction allowing trainees to practice virtual clipping surgeries on real patient-specific vessel geometries. By using specialized finite element (FEM) algorithms (fast finite element method, matrix condensation) combined with GPU acceleration, we can achieve the necessary frame rate for smooth real-time interaction with the detailed models needed for a realistic simulation of the vessel wall deformation caused by the clamping with surgical clips. Vessel wall geometries for typical training scenarios were obtained from 3D-reconstructed medical image data, while for the instruments (clipping forceps, various types of clips, suction tubes) we use models provided by manufacturer Aesculap AG. Collisions between vessel and instruments have to be continuously detected and transformed into corresponding boundary conditions and feedback forces, calculated using a contact plane method. After a training, the achieved result can be assessed based on various criteria, including a simulation of the residual blood flow into the aneurysm. Rigid models of the surgical access and surrounding brain tissue, plus coupling a real forceps to the haptic input device further increase the realism of the simulation.

  15. Coil Embolization for Intracranial Aneurysms

    PubMed Central

    2006-01-01

    Executive Summary Objective To determine the effectiveness and cost-effectiveness of coil embolization compared with surgical clipping to treat intracranial aneurysms. The Technology Endovascular coil embolization is a percutaneous approach to treat an intracranial aneurysm from within the blood vessel without the need of a craniotomy. In this procedure, a microcatheter is inserted into the femoral artery near the groin and navigated to the site of the aneurysm. Small helical platinum coils are deployed through the microcatheter to fill the aneurysm, and prevent it from further expansion and rupture. Health Canada has approved numerous types of coils and coil delivery systems to treat intracranial aneurysms. The most favoured are controlled detachable coils. Coil embolization may be used with other adjunct endovascular devices such as stents and balloons. Background Intracranial Aneurysms Intracranial aneurysms are the dilation or ballooning of part of a blood vessel in the brain. Intracranial aneurysms range in size from small (<12 mm in diameter) to large (12–25 mm), and to giant (>25 mm). There are 3 main types of aneurysms. Fusiform aneurysms involve the entire circumference of the artery; saccular aneurysms have outpouchings; and dissecting aneurysms have tears in the arterial wall. Berry aneurysms are saccular aneurysms with well-defined necks. Intracranial aneurysms may occur in any blood vessel of the brain; however, they are most commonly found at the branch points of large arteries that form the circle of Willis at the base of the brain. In 85% to 95% of patients, they are found in the anterior circulation. Aneurysms in the posterior circulation are less frequent, and are more difficult to treat surgically due to inaccessibility. Most intracranial aneurysms are small and asymptomatic. Large aneurysms may have a mass effect, causing compression on the brain and cranial nerves and neurological deficits. When an intracranial aneurysm ruptures and bleeds, resulting in a subarachnoid hemorrhage (SAH), the mortality rate can be 40% to 50%, with severe morbidity of 10% to 20%. The reported overall risk of rupture is 1.9% per year and is higher for women, cigarette smokers, and cocaine users, and in aneurysms that are symptomatic, greater than 10 mm in diameter, or located in the posterior circulation. If left untreated, there is a considerable risk of repeat hemorrhage in a ruptured aneurysm that results in increased mortality. In Ontario, intracranial aneurysms occur in about 1% to 4% of the population, and the annual incidence of SAH is about 10 cases per 100,000 people. In 2004-2005, about 660 intracranial aneurysm repairs were performed in Ontario. Treatment of Intracranial Aneurysms Treatment of an unruptured aneurysm attempts to prevent the aneurysm from rupturing. The treatment of a ruptured intracranial aneurysm aims to prevent further hemorrhage. There are 3 approaches to treating an intracranial aneurysm. Small, asymptomatic aneurysms less than 10 mm in diameter may be monitored without any intervention other than treatment for underlying risk factors such as hypertension. Open surgical clipping, involves craniotomy, brain retraction, and placement of a silver clip across the neck of the aneurysm while a patient is under general anesthesia. This procedure is associated with surgical risks and neurological deficits. Endovascular coil embolization, introduced in the 1990s, is the health technology under review. Literature Review Methods The Medical Advisory Secretariat searched the International Health Technology Assessment (INAHTA) Database and the Cochrane Database of Systematic Reviews to identify relevant systematic reviews. OVID Medline, Medline In-Process and Other Non-Indexed Citations, and Embase were searched for English-language journal articles that reported primary data on the effectiveness or cost-effectiveness of treatments for intracranial aneurysms, obtained in a clinical setting or analyses of primary data maintained in registers or institutional databases. Internet searches of Medscape and manufacturers’ databases were conducted to identify product information and recent reports on trials that were unpublished but that were presented at international conferences. Four systematic reviews, 3 reports on 2 randomized controlled trials comparing coil embolization with surgical clipping of ruptured aneurysms, 30 observational studies, and 3 economic analysis reports were included in this review. Results Safety and Effectiveness Coil embolization appears to be a safe procedure. Complications associated with coil embolization ranged from 8.6% to 18.6% with a median of about 10.6%. Observational studies showed that coil embolization is associated with lower complication rates than surgical clipping (permanent complication 3-7% versus 10.9%; overall 23% versus 46% respectively, p=0.009). Common complications of coil embolization are thrombo-embolic events (2.5%–14.5%), perforation of aneurysm (2.3%–4.7%), parent artery obstruction (2%–3%), collapsed coils (8%), coil malposition (14.6%), and coil migration (0.5%–3%). Randomized controlled trials showed that for ruptured intracranial aneurysms with SAH, suitable for both coil embolization and surgical clipping (mostly saccular aneurysms <10 mm in diameter located in the anterior circulation) in people with good clinical condition:Coil embolization resulted in a statistically significant 23.9% relative risk reduction and 7% absolute risk reduction in the composite rate of death and dependency compared to surgical clipping (modified Rankin score 3–6) at 1-year. The advantage of coil embolization over surgical clipping varies widely with aneurysm location, but endovascular treatment seems beneficial for all sites. There were less deaths in the first 7 years following coil embolization compared to surgical clipping (10.8% vs 13.7%). This survival benefit seemed to be consistent over time, and was statistically significant (log-rank p= 0.03). Coil embolization is associated with less frequent MRI-detected superficial brain deficits and ischemic lesions at 1-year. The 1- year rebleeding rate was 2.4% after coil embolization and 1% for surgical clipping. Confirmed rebleeding from the repaired aneurysm after the first year and up to year eight was low and not significantly different between coil embolization and surgical clipping (7 patients for coil embolization vs 2 patients for surgical clipping, log-rank p=0.22). Observational studies showed that patients with SAH and good clinical grade had better 6-month outcomes and lower risk of symptomatic cerebral vasospasm after coil embolization compared to surgical clipping. For unruptured intracranial aneurysms, there were no randomized controlled trials that compared coil embolization to surgical clipping. Large observational studies showed that: The risk of rupture in unruptured aneurysms less than 10 mm in diameter is about 0.05% per year for patients with no pervious history of SAH from another aneurysm. The risk of rupture increases with history of SAH and as the diameter of the aneurysm reaches 10 mm or more. Coil embolization reduced the composite rate of in hospital deaths and discharge to long-term or short-term care facilities compared to surgical clipping (Odds Ratio 2.2, 95% CI 1.6–3.1, p<0.001). The improvement in discharge disposition was highest in people older than 65 years. In-hospital mortality rate following treatment of intracranial aneurysm ranged from 0.5% to 1.7% for coil embolization and from 2.1% to 3.5% for surgical clipping. The overall 1-year mortality rate was 3.1% for coil embolization and 2.3% for surgical clipping. One-year morbidity rate was 6.4% for coil embolization and 9.8% for surgical clipping. It is not clear whether these differences were statistically significant. Coil embolization is associated with shorter hospital stay compared to surgical clipping. For both ruptured and unruptured aneurysms, the outcome of coil embolization does not appear to be dependent on age, whereas surgical clipping has been shown to yield worse outcome for patients older than 64 years. Angiographic Efficiency and Recurrences The main drawback of coil embolization is its low angiographic efficiency. The percentage of complete aneurysm occlusion after coil embolization (27%–79%, median 55%) remains lower than that achieved with surgical clipping (82%–100%). However, about 90% of coiled aneurysms achieve near total occlusion or better. Incompletely coiled aneurysms have been shown to have higher aneurysm recurrence rates ranging from 7% to 39% for coil embolization compared to 2.9% for surgical clipping. Recurrence is defined as refilling of the neck, sac, or dome of a successfully treated aneurysm as shown on an angiogram. The long-term clinical significance of incomplete occlusion following coil embolization is unknown, but in one case series, 20% of patients had major recurrences, and 50% of these required further treatment. Long-Term Outcomes A large international randomized trial reported that the survival benefit from coil embolization was sustained for at least 7 years. The rebleeding rate between year 2 and year 8 following coil embolization was low and not significantly different from that of surgical clipping. However, high quality long-term angiographic evidence is lacking. Accordingly, there is uncertainty about long-term occlusion status, coil durability, and recurrence rates. While surgical clipping is associated with higher immediate procedural risks, its long-term effectiveness has been established. Indications and Contraindications Coil embolization offers treatment for people at increased risk for craniotomy, such as those over 65 years of age, with poor clinical status, or with comorbid conditions. The technology also makes it possible to treat surgical high-risk aneurysms. Not all aneurysms are suitable for coil embolization. Suitability depends on the size, anatomy, and location of the aneurysm. Aneurysms more than 10 mm in diameter or with an aneurysm neck greater than or equal to 4 mm are less likely to achieve total occlusion. They are also more prone to aneurysm recurrences and to complications such as coil compaction or parent vessel occlusion. Aneurysms with a dome to neck ratio of less than 1 have been shown to have lower obliteration rates and poorer outcome following coil embolization. Furthermore, aneurysms in the middle cerebral artery bifurcation are less suitable for coil embolization. For some aneurysms, treatment may require the use of both coil embolization and surgical clipping or adjunctive technologies, such as stents and balloons, to obtain optimal results. Diffusion Information from 3 countries indicates that coil embolization is a rapidly diffusing technology. For example, it accounted for about 40% of aneurysm treatments in the United Kingdom. In Ontario, coil embolization is an insured health service, with the same fee code and fee schedule as open surgical repair requiring craniotomy. Other costs associated with coil embolization are covered under hospitals’ global budgets. Utilization data showed that in 2004-2005, coil embolization accounted for about 38% (251 cases) of all intracranial aneurysm repairs in the province. With the 2005 publication of the positive long-term survival data from the International Subarachnoid Aneursym Trial, the pressure for diffusion will likely increase. Economic Analysis Recent economic studies show that treatment of unruptured intracranial aneurysms smaller than 10 mm in diameter in people with no previous history of SAH, either by coil embolization or surgical clipping, would not be effective or cost-effective. However, in patients with aneurysms that are greater than or equal to 10 mm or symptomatic, or in patients with a history of SAH, treatment appears to be cost-effective. In Ontario, the average device cost of coil embolization per case was estimated to be about $7,500 higher than surgical clipping. Assuming that the total number of intracranial aneurysm repairs in Ontario increases to 750 in the fiscal year of 2007, and assuming that up to 60% (450 cases) of these will be repaired by coil embolization, the difference in device costs for the 450 cases (including a 15% recurrence rate) would be approximately $3.8 million. This figure does not include capital costs (e.g. $3 million for an angiosuite), additional human resources required, or costs of follow-up. The increase in expenditures associated with coil embolization may be offset partially, by shorter operating room times and hospitalization stays for endovascular repair of unruptured aneurysms; however, the impact of these cost savings is probably not likely to be greater than 25% of the total outlay since the majority of cases involve ruptured aneurysms. Furthermore, the recent growth in aneurysm repair has predominantly been in the area of coil embolization presumably for patients for whom surgical clipping would not be advised; therefore, no offset of surgical clipping costs could be applied in such cases. For ruptured aneurysms, downstream cost savings from endovascular repair are likely to be minimal even though the savings for individual cases may be substantial due to lower perioperative complications for endovascular aneurysm repair. Guidelines The two Guidance documents issued by the National Institute of Clinical Excellence (UK) in 2005 support the use of coil embolization for both unruptured and ruptured (SAH) intracranial aneurysms, provided that procedures are in place for informed consent, audit, and clinical governance, and that the procedure is performed in specialist units with expertise in the endovascular treatment of intracranial aneurysms. Conclusion For people in good clinical condition following subarachnoid hemorrhage from an acute ruptured intracranial aneurysm suitable for either surgical clipping or endovascular repair, coil embolization results in improved independent survival in the first year and improved survival for up to seven years compared to surgical clipping. The rebleeding rate is low and not significantly different between the two procedures after the first year. However, there is uncertainty regarding the long-term occlusion status, durability of the stent graft, and long-term complications. For people with unruptured aneurysms, level 4 evidence suggests that coil embolization may be associated with comparable or less mortality and morbidity, shorter hospital stay, and less need for discharge to short-term rehabilitation facilities. The greatest benefit was observed in people over 65 years of age. In these patients, the decision regarding treatment needs to be based on the assessment of the risk of rupture against the risk of the procedure, as well as the morphology of the aneurysm. In people who require treatment for intracranial aneurysm, but for whom surgical clipping is too risky or not feasible, coil embolization provides survival benefits over surgical clipping, even though the outcomes may not be as favourable as in people in good clinical condition and with small aneurysms. The procedure may be considered under the following circumstances provided that the aneurysm is suitable for coil embolization: Patients in poor/unstable clinical or neurological state Patients at high risk for surgical repair (e.g. people>age 65 or with comorbidity), or Aneurysm(s) with poor accessibility or visibility for surgical treatment due to their location (e.g. ophthalmic or basilar tip aneurysms) Compared to small aneurysms with a narrow neck in the anterior circulation, large aneurysms (> 10 mm in diameter), aneurysms with a wide neck (>4mm in diameter), and aneurysms in the posterior circulation have lower occlusion rates and higher rate of hemorrhage when treated with coil embolization. The extent of aneurysm obliteration after coil embolization remains lower than that achieved with surgical clipping. Aneurysm recurrences after successful coiling may require repeat treatment with endovascular or surgical procedures. Experts caution that long-term angiographic outcomes of coil embolization are unknown at this time. Informed consent for and long-term follow-up after coil embolization are recommended. The decision to treat an intracranial aneurysm with surgical clipping or coil embolization needs to be made jointly by the neurosurgeon and neuro-intervention specialist, based on the clinical status of the patient, the size and morphology of the aneurysm, and the preference of the patient. The performance of endovascular coil embolization should take place in centres with expertise in both neurosurgery and endovascular neuro-interventions, with adequate treatment volumes to maintain good outcomes. Distribution of the technology should also take into account that patients with SAH should be treated as soon as possible with minimal disruption. PMID:23074479

  16. Catering to millennial learners: assessing and improving fine-needle aspiration performance.

    PubMed

    Rowse, Phillip G; Ruparel, Raaj K; AlJamal, Yazan N; Abdelsattar, Jad M; Heller, Stephanie F; Farley, David R

    2014-01-01

    Fine-needle aspiration (FNA) of a palpable cervical lymph node is a straightforward procedure that should be safely performed by educated general surgery (GS) trainees. Retention of technical skill is suspect, unless sequential learning experiences are provided. However, voluntary learning experiences are no guarantee that trainees will actually use the resource. A 3-minute objective structured assessment of technical skill-type station was created to assess GS trainee performance using FNA. Objective criteria were developed and a checklist was generated (perfect score = 24). Following abysmal performance of 11 postgraduate year (PGY)-4 trainees on the FNA station of our semiannual surgical skills assessment ("X-Games"), we provided all GS residents with electronic access to a 90-second YouTube video clip demonstrating proper FNA technique. PGY-2 (n = 11) and PGY-3 (n = 10) residents subsequently were tested on FNA technique 5 and 12 days later, respectively. All 32 trainees completed the station in less than 3 minutes. Overall scores ranged from 4 to 24 (mean = 14.9). PGY-4 residents assessed before the creation of the video clip scored lowest (range: 4-18, mean = 11.4). PGY-3 residents (range: 10-22, mean = 17.8) and PGY-2 residents (range: 10-24, mean = 15.8) subsequently scored higher (p < 0.05). Ten residents admitted watching the 90-second FNA video clip and scored higher (mean = 21.7) than the 11 residents that admitted they did not watch the clip (mean = 13.1, p < 0.001). Of the 11 trainees who did not watch the video, 6 claimed they did not have time, and 5 felt it would not be useful to them. Overall performance of FNA was poor in 32 midlevel GS residents. However, a 90-second video clip demonstrating proper FNA technique viewed less than 2 weeks before the examination significantly elevated scores. Half of trainees given the chance to learn online did not take the opportunity to view the video clip. Although preemptive learning is effective, future efforts should attempt to improve self-directed learning habits of trainees and evaluate actual long-term skill retention. Copyright © 2014. Published by Elsevier Inc.

  17. Predicting Factors of Chronic Subdural Hematoma Following Surgical Clipping in Unruptured and Ruptured Intracranial Aneurysm

    PubMed Central

    Kwon, Min-Yong; Kim, Chang-Hyun

    2016-01-01

    Objective The aim of this study is to analyze the differences in the incidence, predicting factors, and clinical course of chronic subdural hematoma (CSDH) following surgical clipping between unruptured (UIA) and ruptured intracranial aneurysm (RIA). Methods We conducted a retrospective analysis of 752 patients (UIA : 368 and RIA : 384) who underwent surgical clipping during 8 years. The incidence and predicting factors of CSDH development in the UIA and RIA were compared according to medical records and radiological data. Results The incidence of postoperative CSDH was higher in the UIA (10.9%) than in the RIA (3.1%) (p=0.000). In multivariate analysis, a high Hounsfield (HF) unit (blood clots) for subdural fluid collection (SFC), persistence of SFC ≥5 mm and male sex in the UIA and A high HF unit for SFC and SFC ≥5 mm without progression to hydrocephalus in the RIA were identified as the independent predicting factors for CSDH development (p<0.05). Conclusion There were differences in the incidence and predicting factors for CSDH following surgical clipping between UIA and RIA. Blood clots in the subdural space and persistence of SFC ≥5 mm were predicting factors in both UIA and RIA. However, progression to hydrocephalus may have in part contributed to low CSDH development in the RIA. We suggest that cleaning of blood clots in the subdural space and efforts to minimize SFC ≥5 mm at the end of surgery is helpful to prevent CSDH following aneurysmal clipping. PMID:27651863

  18. Treatment of cerebral aneurysms in children: analysis of the Kids' Inpatient Database.

    PubMed

    Alawi, Aws; Edgell, Randall C; Elbabaa, Samer K; Callison, R Charles; Khalili, Yasir Al; Allam, Hesham; Alshekhlee, Amer

    2014-07-01

    OBJECT.: Endovascular coiling and surgical clipping are viable treatment options of cerebral aneurysms. Outcome data of these treatments in children are limited. The objective of this study was to determine hospital mortality and complication rates associated with surgical clipping and coil embolization of cerebral aneurysms in children, and to evaluate the trend of hospitals' use of these treatments. The authors identified a cohort of children admitted with the diagnoses of cerebral aneurysms and aneurysmal subarachnoid hemorrhage from the Kids' Inpatient Database for the years 1998 through 2009. Hospital-associated complications and in-hospital mortality were compared between the treatment groups and stratified by aneurysmal rupture status. A multivariate regression analysis was used to identify independent variables associated with in-hospital mortality. The Cochrane-Armitage test was used to assess the trend of hospital use of these operations. A total of 1120 children were included in this analysis; 200 (18%) underwent aneurysmal clipping and 920 (82%) underwent endovascular coiling. Overall in-hospital mortality was higher in the surgical clipping group compared with the coil embolization group (6.09% vs 1.65%, respectively; adjusted odds ratio [OR] 2.52, 95% CI 0.97-6.53, p = 0.05). The risk of postoperative stroke or hemorrhage was similar between the two treatment groups (p = 0.86). Pulmonary complications and systemic infection were higher in the surgical clipping population (p < 0.05). The rate of US hospitals' use of endovascular coiling has significantly increased over the years included in this study (p < 0.0001). Teaching hospitals were associated with a lower risk of death (OR 0.13, 95% CI 0.03-0.46; p = 0.001). Although both treatments are valid, endovascular coiling was associated with fewer deaths and shorter hospital stays than clip placement. The trend of hospitals' use of coiling operations has increased in recent years.

  19. [Zwipp Percutaneous Suture of the Achilles Tendon with the Dresden Instruments].

    PubMed

    Chmielnicki, M; Prokop, A

    2016-06-01

    Rupture of the Achilles tendon is the most common rupture of a tendon in man. Acute rupture of the Achilles tendon may be treated in a variety of manners, including conservative treatment, open suture and percutaneous suture. Surgical treatment of active patients is recommended, as the risk of re-rupture is greater after non-surgical treatment. The aim of surgery is adequate treatment of Achilles tendon rupture with a low rate of complications, high comfort for patients and fast social and occupational rehabilitation. The indication for surgical treatment of Achilles tendon rupture predominantly includes ruptures in active patients, with the goal of optimal functional rehabilitation. Furthermore, the percutaneous technique protects soft tissue, with a lower rate of wound healing disorders and infection than with open surgical treatment. In our clinic we perform the percutaneous suturing technique with the Dresden instruments. The surgical technique and functional aftercare are shown in a video clip. Between 2007 and 2013, we treated 212 patients with acute Achilles tendon rupture by surgery with the Dresden instruments. There were 7 re-ruptures (3.3 %) and one case of infection within one year of surgery. Percutaneous Achilles tendon suture technique with the Dresden instruments is a safe operation that protects soft tissue. Patient satisfaction is high and the rate of complications is low. This allows rapid social and occupational rehabilitation. Georg Thieme Verlag KG Stuttgart · New York.

  20. Definition and visualisation of regions of interest in post-prostatectomy image-guided intensity modulated radiotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bell, Linda J, E-mail: linda.bell1@health.nsw.gov.au; Cox, Jennifer; Faculty of Health Sciences, University of Sydney, Lidcombe, New South Wales

    2014-09-15

    Standard post-prostatectomy radiotherapy (PPRT) image verification uses bony anatomy alignment. However, the prostate bed (PB) moves independently of bony anatomy. Cone beam computed tomography (CBCT) can be used to soft tissue match, so radiation therapists (RTs) must understand pelvic anatomy and PPRT clinical target volumes (CTV). The aims of this study are to define regions of interest (ROI) to be used in soft tissue matching image guidance and determine their visibility on planning CT (PCT) and CBCT. Published CTV guidelines were used to select ROIs. The PCT scans (n = 23) and CBCT scans (n = 105) of 23 post-prostatectomymore » patients were reviewed. Details on ROI identification were recorded. Eighteen patients had surgical clips. All ROIs were identified on PCTs at least 90% of the time apart from mesorectal fascia (MF) (87%) due to superior image quality. When surgical clips are present, the seminal vesicle bed (SVB) was only seen in 2.3% of CBCTs and MF was unidentifiable. Most other structures were well identified on CBCT. The anterior rectal wall (ARW) was identified in 81.4% of images and penile bulb (PB) in 68.6%. In the absence of surgical clips, the MF and SVB were always identified; the ARW was identified in 89.5% of CBCTs and PB in 73.7%. Surgical clips should be used as ROIs when present to define SVB and MF. In the absence of clips, SVB, MF and ARW can be used. RTs must have a strong knowledge of soft tissue anatomy and PPRT CTV to ensure coverage and enable soft tissue matching.« less

  1. A new method for digital video documentation in surgical procedures and minimally invasive surgery.

    PubMed

    Wurnig, P N; Hollaus, P H; Wurnig, C H; Wolf, R K; Ohtsuka, T; Pridun, N S

    2003-02-01

    Documentation of surgical procedures is limited to the accuracy of description, which depends on the vocabulary and the descriptive prowess of the surgeon. Even analog video recording could not solve the problem of documentation satisfactorily due to the abundance of recorded material. By capturing the video digitally, most problems are solved in the circumstances described in this article. We developed a cheap and useful digital video capturing system that consists of conventional computer components. Video images and clips can be captured intraoperatively and are immediately available. The system is a commercial personal computer specially configured for digital video capturing and is connected by wire to the video tower. Filming was done with a conventional endoscopic video camera. A total of 65 open and endoscopic procedures were documented in an orthopedic and a thoracic surgery unit. The median number of clips per surgical procedure was 6 (range, 1-17), and the median storage volume was 49 MB (range, 3-360 MB) in compressed form. The median duration of a video clip was 4 min 25 s (range, 45 s to 21 min). Median time for editing a video clip was 12 min for an advanced user (including cutting, title for the movie, and compression). The quality of the clips renders them suitable for presentations. This digital video documentation system allows easy capturing of intraoperative video sequences in high quality. All possibilities of documentation can be performed. With the use of an endoscopic video camera, no compromises with respect to sterility and surgical elbowroom are necessary. The cost is much lower than commercially available systems, and setting changes can be performed easily without trained specialists.

  2. Outcome of Limited Video-Assisted Lumbar Sympathetic Block for Plantar Hyperhidrosis Using Clipping Method.

    PubMed

    Yun, Seok Won; Kim, Yun Seok; Lee, Yongjik; Lim, Han Jung; Park, Soon Ik; Jung, Jong Pil; Park, Chang Ryul

    2017-01-01

    There are many ways to treat focal hyperhidrosis, including surgeries for palmar and axillary hyperhidrosis. However, doctors and patients tend to be reluctant to perform surgery for plantar hyperhidrosis due to misconceptions and prejudices about surgical treatment. In addition, few studies have reported the outcome of surgeries for plantar hyperhidrosis. Therefore, the objective of this study was to determine the outcome (early and late postoperative satisfaction, complication, compensatory hyperhidrosis, recurrence rate, and efficiency) of surgical treatment for plantar hyperhidrosis. From August 2014 to October 2015, lumbar sympathetic block (LSB) was performed in 82 patients with plantar hyperhidrosis using clipping method. Limited video-assisted LSB was performed using 5 mm ligamax-clip or 3 mm horizontal-clip after identifying L3-4 sympathetic ganglion through finger-touch and endoscopic vision. Of the 82 patients, 45 were male and 37 were female. Their mean age was 26.38 years (range, 14-51 years). Mean follow-up time was 6.60 ± 3.56 months. Mean early postoperative satisfaction score was 9.6 on the 10th day postoperative evaluation. At more than 1 month later, the mean late postoperative satisfaction score was 9.2. There was no significant difference in early postoperative satisfaction score between clipping level L3 and L4/5. However, late postoperative satisfaction score was significantly better in the L3 group than that in the L4/5 group. Patient's age and body mass index did not affect the satisfaction score. However, male patients and patients who had history of hyperhidrosis operation showed higher satisfaction score than others. Limited video-assisted LSB using clip provided good results with minimal complications and low compensatory hidrosis, contrary to the prejudice toward it. Therefore, surgical treatment is recommended for plantar hyperhidrosis.

  3. Intraoperative validation of CT-based lymph nodal levels, sublevels IIa and IIb: Is it of clinical relevance in selective radiation therapy?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Levendag, Peter; Gregoire, Vincent; Hamoir, Marc

    2005-07-01

    Purpose: The objectives of this study are to discuss the intraoperative validation of CT-based boundaries of lymph nodal levels in the neck, and in particular the clinical relevance of the delineation of sublevels IIa and IIb in case of selective radiation therapy (RT). Methods and Materials: To validate the radiologically defined level contours, clips were positioned intraoperatively at the level boundaries defined by surgical anatomy. In 10 consecutive patients, clips were placed, at the time of a neck dissection being performed, at the most cranial border of the neck. Anterior-posterior and lateral X-ray films were obtained intraoperatively. Next, in 3more » patients, neck levels were contoured on preoperative contrast-enhanced CT scans according to the international consensus guidelines. From each of these 3 patients, an intraoperative CT scan was also obtained, with clips placed at the surgical-anatomy-based level boundaries. The preoperative (CT-based) and intraoperative (surgery-defined) CT scans were matched. Results: Clips placed at the most cranial part of the neck lined up at the caudal part of the transverse process of the cervical vertebra C-I. The posterior border of surgical level IIa (spinal accessory nerve [SAN]) did not match with the posterior border of CT-based level IIa (internal jugular vein [IJV]). Other surgical boundaries and CT-based contours were in good agreement. Conclusions: The cranial border of the neck, i.e., the cranial border of level IIa/IIb, corresponds to the caudal edge of the lateral process of C-I. Except for the posterior border between level IIa and level IIb, a perfect match was observed between the other surgical-clip-identified levels II-V boundaries (surgical-anatomy) and the CT-based delineation contours. It is argued that (1) because of the parotid gland overlapping part of level II, and (2) the frequent infestation of occult metastatic cells in the lymph channels around the IJV, the division of level II into radiologic sublevels IIa and IIb may not be relevant. Sparing of, for example, the ipsilateral parotid gland in selective RT can even be a treacherous undertaking with respect to regional tumor control. In contrast, the surgeon's reasoning for preserving the surgical sublevel IIb is that the morbidity associated with dissection of the supraspinal accessory nerve compartment of level II is reduced, whereas there is evidence from the surgical literature that no extra risk for regional tumor control is observed. Therefore, in selective neck dissections, the division into surgical sublevels IIa/IIb makes sense.« less

  4. Aneurysm treatment practice patterns for newly appointed dual-trained cerebrovascular/endovascular neurosurgeons: Comparison of open surgical to neuroendovascular procedures in the first 2 years of academic practice.

    PubMed

    Jiang, Bowen; Bender, Matthew T; Hasjim, Bima; Hsu, Frank P K; Tamargo, Rafael J; Huang, Judy; Colby, Geoffrey P; Coon, Alexander L; Lin, Li-Mei

    2017-01-01

    The practice patterns of a hybrid open cerebrovascular/neuroendovascular (CVNV) neurosurgeon in early academic practice is unknown. We performed a multi-institutional retrospective cohort study of patients with cerebral aneurysms that were treated within the first 24 months of the neurosurgeon's practice. A total of 533 aneurysms were treated by the three senior authors within the first 24 months of their academic practice. Of these aneurysms, 172 were treated with microsurgical clipping, 191 with coiling, and 170 with flow diversion. Treatment in the setting of acute subarachnoid hemorrhage (SAH) occurred in 23% (122/533) of the aneurysms. Majority of the clipped aneurysms (70%, 121/172) were anterior cerebral artery (ACA), anterior communicating artery (ACOM), or middle cerebral artery (MCA) in location. In comparison, only 23% (82/361) of aneurysms treated with coiling or flow diversion therapy were ACA, ACOM, or MCA in location ( P < 0.05). Additionally, majority of the flow diverted aneurysm (65%, 111/170) were cavernous or ophthalmic/paraophthalmic in location. During the second year of practice, there appeared to be a trend towards more aneurysms treated with neuroendovascular techniques (22% increase), particularly in flow diversion. Although the CVNV neurosurgeon treats cerebral aneurysms more commonly with neuroendovascular techniques, a third of the cerebral aneurysms are still selected for microsurgical clipping. Aneurysms located along the ACA/ACOM or MCA are the most frequent aneurysms reserved for microsurgical clipping. The CVNV neurosurgeon must be prepared to manage a high percentage of ACA/ACOM or MCA aneurysms microsurgically.

  5. Cerebral Aneurysm Clipping Surgery Simulation Using Patient-Specific 3D Printing and Silicone Casting.

    PubMed

    Ryan, Justin R; Almefty, Kaith K; Nakaji, Peter; Frakes, David H

    2016-04-01

    Neurosurgery simulator development is growing as practitioners recognize the need for improved instructional and rehearsal platforms to improve procedural skills and patient care. In addition, changes in practice patterns have decreased the volume of specific cases, such as aneurysm clippings, which reduces the opportunity for operating room experience. The authors developed a hands-on, dimensionally accurate model for aneurysm clipping using patient-derived anatomic data and three-dimensional (3D) printing. Design of the model focused on reproducibility as well as adaptability to new patient geometry. A modular, reproducible, and patient-derived medical simulacrum was developed for medical learners to practice aneurysmal clipping procedures. Various forms of 3D printing were used to develop a geometrically accurate cranium and vascular tree featuring 9 patient-derived aneurysms. 3D printing in conjunction with elastomeric casting was leveraged to achieve a patient-derived brain model with tactile properties not yet available from commercial 3D printing technology. An educational pilot study was performed to gauge simulation efficacy. Through the novel manufacturing process, a patient-derived simulacrum was developed for neurovascular surgical simulation. A follow-up qualitative study suggests potential to enhance current educational programs; assessments support the efficacy of the simulacrum. The proposed aneurysm clipping simulator has the potential to improve learning experiences in surgical environment. 3D printing and elastomeric casting can produce patient-derived models for a dynamic learning environment that add value to surgical training and preparation. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. Laparoscopic enucleation of liver tumors. Corkscrew technique revisited.

    PubMed

    Makdissi, Fabio F; Surjan, Rodrigo C T; Machado, Marcel Autran C

    2009-03-01

    Enucleation of small lesions located near the hepatic surface can be achieved with low morbidity and mortality. This article describes a simple laparoscopic technique for enucleation of liver tumors. After inspection and intraoperative ultrasonography, Glisson's capsule is marked with eletrocautery 2 cm away from the tumor margin. Ultrasonography is used to ascertain surgical margin right before liver transection. Hemihepatic ischemia is applied and marked area is anchored by stitches. The suture is held together by metallic clips and upward traction is performed, facilitating the transection of the parenchyma and correct identification of vascular and biliary structures. This technique has been successfully employed in six consecutive patients. There were four men and two women, mean age 50.3 years. Four patients underwent liver resection for malignant disease and two for benign liver neoplasm. Pathologic surgical margins were free in all cases and mean hospital stay was 2 days. No postoperative mortality was observed. This technique may facilitate laparoscopic nonanatomical liver resection and reduce risk of positive surgical margins. It is also useful in combination with anatomical laparoscopic liver resections such as right or left hemihepatectomies in patients with bilateral liver tumors as occurred in one of our patients.

  7. Sympathetic block by metal clips may be a reversible operation.

    PubMed

    Thomsen, Lars L; Mikkelsen, Rasmus T; Derejko, Miroslawa; Schrøder, Henrik D; Licht, Peter B

    2014-12-01

    Thoracoscopic sympathectomy is now used routinely to treat patients with disabling primary hyperhidrosis or facial blushing. Published results are excellent, but side effects, such as compensatory sweating, are also very frequent. The surgical techniques used and the levels of targeting the sympathetic chain vary tremendously. Most surgeons transect or resect the sympathetic chain, but application of a metal clip that blocks transmission of nerve impulses in the sympathetic chain is used increasingly worldwide. This approach offers potential reversibility if patients regret surgery, but the question of reversibility remains controversial. Two recent experimental studies found severe histological signs of nerve damage 4-6 weeks after clip removal, but they only used conventional histopathological staining methods. Thoracoscopic clipping of the sympathetic trunk was performed in adult sheep, and the clip was removed thoracoscopically after 7 days. Following another 4 weeks (n = 6) or 12 weeks (n = 3), the sympathetic trunks were harvested and analysed by conventional and specific nerve tissue immunohistochemical stains (S100, neurofilament protein and synaptophysin). The contralateral sympathetic chains were used as controls. Conventional and immunohistochemical stains demonstrated severe signs of neural damage on the operated side 4 weeks after clip removal. After 12 weeks, these changes had decreased markedly and conventional histology had almost normalized. Conventional and immunohistochemical stains confirmed that application of metal clips to the sympathetic chain caused severe histological damage in the sympathetic trunk that remained visible 4 weeks after clip removal. However, after 12 weeks, these signs of damage had clearly decreased, which suggests in theory that application of metal clips to the sympathetic chain is a reversible procedure if only the observation period is prolonged. Further studies with longer periods between application and removal as well as investigations of nerve conduction should be encouraged, because we do not know whether histological reversibility at cellular level translates into physiological reversibility and possible correlation of nerve trauma with the duration of the applied clip. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  8. Microsurgery Simulator of Cerebral Aneurysm Clipping with Interactive Cerebral Deformation Featuring a Virtual Arachnoid.

    PubMed

    Shono, Naoyuki; Kin, Taichi; Nomura, Seiji; Miyawaki, Satoru; Saito, Toki; Imai, Hideaki; Nakatomi, Hirofumi; Oyama, Hiroshi; Saito, Nobuhito

    2018-05-01

    A virtual reality simulator for aneurysmal clipping surgery is an attractive research target for neurosurgeons. Brain deformation is one of the most important functionalities necessary for an accurate clipping simulator and is vastly affected by the status of the supporting tissue, such as the arachnoid membrane. However, no virtual reality simulator implementing the supporting tissue of the brain has yet been developed. To develop a virtual reality clipping simulator possessing interactive brain deforming capability closely dependent on arachnoid dissection and apply it to clinical cases. Three-dimensional computer graphics models of cerebral tissue and surrounding structures were extracted from medical images. We developed a new method for modifiable cerebral tissue complex deformation by incorporating a nonmedical image-derived virtual arachnoid/trabecula in a process called multitissue integrated interactive deformation (MTIID). MTIID made it possible for cerebral tissue complexes to selectively deform at the site of dissection. Simulations for 8 cases of actual clipping surgery were performed before surgery and evaluated for their usefulness in surgical approach planning. Preoperatively, each operative field was precisely reproduced and visualized with the virtual brain retraction defined by users. The clear visualization of the optimal approach to treating the aneurysm via an appropriate arachnoid incision was possible with MTIID. A virtual clipping simulator mainly focusing on supporting tissues and less on physical properties seemed to be useful in the surgical simulation of cerebral aneurysm clipping. To our knowledge, this article is the first to report brain deformation based on supporting tissues.

  9. Preoperative endoscopic titanium clip placement facilitates intraoperative localization of early-stage esophageal cancer or severe dysplasia.

    PubMed

    Tan, Lei; Feng, Juan; Zhao, Qin; Chen, Ping; Yang, Guotao

    2017-08-02

    Accurate intraoperative localization of esophageal lesions is essential for successful surgical resection. We tested whether preoperative endoscopic placement of titanium clips could facilitate intraoperative localization of early-stage esophageal cancer or severe dysplasia. A prospective randomized clinical trial was performed between May 2012 and July 2014. All enrolled patients received preoperative endoscopy and esophageal endoscopic ultrasound, as well as pathological study on the biopsy specimen, to confirm early stage esophageal cancer or severe dysplasia. One day before the surgical operation, patients in the experimental group received the preoperative endoscopic titanium labeling of esophageal lesions. Then, during the surgical operation, palpitation of titanium clips was used to localize the lesions in these patients. In patients in the control group, palpitation of nodules or esophageal wall mucosal thickening, together with the consideration of the results from preoperative endoscopic and ultrasound studies, was applied to estimate the location of the esophageal lesions. Study outcomes included the proportions of patients having successful intraoperative pre-resection lesion localization, post-esophagectomy lesion visualization, negative upper surgical margin, change of surgical approaches, and positive postoperative pathological diagnosis. A total of 27 patients were enrolled into the study, with 14 in the experimental group and 13 in the control group. Compared to the patients in the control group, a higher proportion of patients in the experimental group had statistically significant successful intraoperative esophageal lesion localization (100 versus 15.3% in the experimental versus control group). Preoperative endoscopic titanium clip placement could facilitate intraoperative localization of early-stage esophageal cancer or severe dysplasia. Current study was registered in Chinese Clinical Trial Registry and World Health Organization International Clinical Trials Registry Platform, ChiCTR-INR-17010949 . Registered 22 March 2017, retrospectively registered.

  10. An Optimized Online Verification Imaging Procedure for External Beam Partial Breast Irradiation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Willis, David J., E-mail: David.Willis@petermac.or; Royal Melbourne Institute of Technology University, Melbourne, Victoria; Kron, Tomas

    2011-07-01

    The purpose of this study was to evaluate the capabilities of a kilovoltage (kV) on-board imager (OBI)-equipped linear accelerator in the setting of on-line verification imaging for external-beam partial breast irradiation. Available imaging techniques were optimized and assessed for image quality using a modified anthropomorphic phantom. Imaging dose was also assessed. Imaging techniques were assessed for physical clearance between patient and treatment machine using a volunteer. Nonorthogonal kV image pairs were identified as optimal in terms of image quality, clearance, and dose. After institutional review board approval, this approach was used for 17 patients receiving accelerated partial breast irradiation. Imagingmore » was performed before every fraction verification with online correction of setup deviations >5 mm (total image sessions = 170). Treatment staff rated risk of collision and visibility of tumor bed surgical clips where present. Image session duration and detected setup deviations were recorded. For all cases, both image projections (n = 34) had low collision risk. Surgical clips were rated as well as visualized in all cases where they were present (n = 5). The average imaging session time was 6 min, 16 sec, and a reduction in duration was observed as staff became familiar with the technique. Setup deviations of up to 1.3 cm were detected before treatment and subsequently confirmed offline. Nonorthogonal kV image pairs allowed effective and efficient online verification for partial breast irradiation. It has yet to be tested in a multicenter study to determine whether it is dependent on skilled treatment staff.« less

  11. Clipping Versus Coiling in the Management of Posterior Communicating Artery Aneurysms with Third Nerve Palsy: A Systematic Review and Meta-Analysis.

    PubMed

    Gaberel, Thomas; Borha, Alin; di Palma, Camille; Emery, Evelyne

    2016-03-01

    To compare surgical clipping with endovascular coiling in terms of recovery from oculomotor nerve palsy (ONP) in the management of posterior communicating artery (PCoA) aneurysms causing third nerve palsy. We conducted a systematic review of the literature and meta-analysis. The meta-analysis included 11 relevant studies involving 384 patients with third nerve palsy caused by PCoA aneurysms at baseline, of whom 257 (67.0%) were treated by clipping and 127 were treated by coiling (33.0%). Pooled odds ratios of the impact of clipping or coiling on complete ONP recovery, lack of ONP recovery, and procedure-related death were calculated. The overall complete ONP recovery rate was 42.5% in the coiling group compared with 83.6% in the clipping group. The increase in complete ONP recovery in the clipping group corresponds to an overall pooled Mantel-Haenszel odds ratio of 4.44 (95% confidence interval = 1.66-11.84). Subgroup analysis revealed a clear benefit of clipping over coiling in patients with ruptured aneurysms, but not in patients with unruptured aneurysms. No procedure-related deaths were reported by any of the 11 studies. Surgical clipping of PCoA aneurysms causing third nerve palsy achieves better ONP recovery than endovascular coiling; this could be particularly true in the case of ruptured aneurysms. In view of the purely observational data, statements about this effect should be made with great caution. A randomized trial would better address the therapeutic dilemma, but pending the results of such a trial, we recommend treating PCoA aneurysms causing ONP with surgery. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. [Choledochal lithiasis and stenosis secondary to the migration of a surgical clip].

    PubMed

    Baldomà España, M; Pernas Canadell, J C; González Ceballos, S

    2014-01-01

    The migration of a clip to the common bile duct after cholecystectomy is an uncommon, usually late, complication that can lead to diverse complications like stone formation, stenosis, and obstruction in the bile duct. We present the case of a patient who presented with signs and symptoms of cholangitis due to clip migration one year after laparoscopic cholecystectomy; endoscopic retrograde cholangiopancreatography and biliary tract stent placement resolved the problem. Copyright © 2011 SERAM. Published by Elsevier Espana. All rights reserved.

  13. Accelerated partial breast irradiation using robotic radiotherapy: a dosimetric comparison with tomotherapy and three-dimensional conformal radiotherapy.

    PubMed

    Rault, Erwann; Lacornerie, Thomas; Dang, Hong-Phuong; Crop, Frederik; Lartigau, Eric; Reynaert, Nick; Pasquier, David

    2016-02-27

    Accelerated partial breast irradiation (APBI) is a new breast treatment modality aiming to reduce treatment time using hypo fractionation. Compared to conventional whole breast irradiation that takes 5 to 6 weeks, APBI is reported to induce worse cosmetic outcomes both when using three-dimensional conformal radiotherapy (3D-CRT) and intensity-modulated radiotherapy (IMRT). These late normal tissue effects may be attributed to the dose volume effect because a large portion of the non-target breast tissue volume (NTBTV) receives a high dose. In the context of APBI, non-coplanar beams could spare the NTBTV more efficiently. This study evaluates the dosimetric benefit of using the Cyberknife (CK) for APBI in comparison to IMRT (Tomotherapy) and three dimensional conformal radiotherapy (3D-CRT). The possibility of using surgical clips, implanted during surgery, to track target movements is investigated first. A phantom of a female thorax was designed in-house using the measurements of 20 patients. Surgical clips of different sizes were inserted inside the breast. A treatment plan was delivered to the mobile and immobile phantom. The motion compensation accuracy was evaluated using three radiochromic films inserted inside the breast. Three dimensional conformal radiotherapy (3D-CRT), Tomotherapy (TOMO) and CK treatment plans were calculated for 10 consecutive patients who received APBI in Lille. To ensure a fair comparison of the three techniques, margins applied to the CTV were set to 10 mm. However, a second CK plan was prepared using 3 mm margins to evaluate the benefits of motion compensation. Only the larger clips (VITALITEC Medium-Large) could be tracked inside the larger breast (all gamma indices below 1 for 1 % of the maximum dose and 1 mm). All techniques meet the guidelines defined in the NSABP/RTOG and SHARE protocols. As the applied dose volume constraints are very strong, insignificant dosimetric differences exist between techniques regarding the PTV coverage and the sparing of the lung and heart. However, the CK may be used to reduce high doses received by the NTBTV more efficiently. Robotic stereotactic radiotherapy may be used for APBI to more efficiently spare the NTBTV and improve cosmetic results of APBI.

  14. Aneurysm treatment practice patterns for newly appointed dual-trained cerebrovascular/endovascular neurosurgeons: Comparison of open surgical to neuroendovascular procedures in the first 2 years of academic practice

    PubMed Central

    Jiang, Bowen; Bender, Matthew T.; Hasjim, Bima; Hsu, Frank P. K.; Tamargo, Rafael J.; Huang, Judy; Colby, Geoffrey P.; Coon, Alexander L.; Lin, Li-Mei

    2017-01-01

    Background: The practice patterns of a hybrid open cerebrovascular/neuroendovascular (CVNV) neurosurgeon in early academic practice is unknown. Methods: We performed a multi-institutional retrospective cohort study of patients with cerebral aneurysms that were treated within the first 24 months of the neurosurgeon’s practice. Results: A total of 533 aneurysms were treated by the three senior authors within the first 24 months of their academic practice. Of these aneurysms, 172 were treated with microsurgical clipping, 191 with coiling, and 170 with flow diversion. Treatment in the setting of acute subarachnoid hemorrhage (SAH) occurred in 23% (122/533) of the aneurysms. Majority of the clipped aneurysms (70%, 121/172) were anterior cerebral artery (ACA), anterior communicating artery (ACOM), or middle cerebral artery (MCA) in location. In comparison, only 23% (82/361) of aneurysms treated with coiling or flow diversion therapy were ACA, ACOM, or MCA in location (P < 0.05). Additionally, majority of the flow diverted aneurysm (65%, 111/170) were cavernous or ophthalmic/paraophthalmic in location. During the second year of practice, there appeared to be a trend towards more aneurysms treated with neuroendovascular techniques (22% increase), particularly in flow diversion. Conclusion: Although the CVNV neurosurgeon treats cerebral aneurysms more commonly with neuroendovascular techniques, a third of the cerebral aneurysms are still selected for microsurgical clipping. Aneurysms located along the ACA/ACOM or MCA are the most frequent aneurysms reserved for microsurgical clipping. The CVNV neurosurgeon must be prepared to manage a high percentage of ACA/ACOM or MCA aneurysms microsurgically. PMID:28808603

  15. Quantitative study of the opticocarotid and carotid-oculomotor windows for the interpeduncular fossa, before and after internal carotid artery mobilization and posterior communicating division.

    PubMed

    Kim, Young-Don; Elhadi, Ali M; Mendes, George A C; Maramreddy, Naveen; Agrawal, Abhishek; Kalb, Samuel; Nakaji, Peter; Spetzler, Robert F; Preul, Mark C

    2015-03-01

    The management of basilar apex (BX) aneurysms remains problematic. We quantified the surgical exposure of the BX through the opticocarotid window (OCW) and the carotid-oculomotor window (COW), before and after mobilization of the internal carotid artery and division of the posterior communicating artery (PCoA). Eleven silicone-injected cadaveric heads were dissected bilaterally. The surgical dissection was divided into 4 major steps: (1) supraorbital modified orbitozygomatic craniotomy, (2) mobilization of the internal carotid artery after drilling out the anterior clinoid process intradurally and cutting the distal dural ring, (3) drilling out the posterior clinoid process and dorsum sellae, and (4) dividing the PCoA from the posterior third portion of the vessel. A frameless navigation system was used to quantify the surgical exposure area of the BX through the OCW and COW. The total surgical area increased significantly from steps 1 to 4 (P < .001) in both OCW and COW groups. Overall, there was a larger total surgical area obtained in the COW compared with the OCW (P = .010). ICA mobilization increased the surgical area for temporary (P < .001) and permanent (P < .003) clip application in both windows. The division of PCoA significantly increased the overall surgical area for permanent clip application (P < .003). Compared with the OCW, the COW had a significantly increased change in the area for permanent clip application in the low-lying group (P = .03). When approaching the BX via the pterion route, the appropriate surgical step and window should be selected according to characteristics of the PCoA and height of the BX.

  16. Surgical approach to giant aneurysms of the anterior circulation.

    PubMed

    Giombini, S; Solero, C L; Ferraresi, S; Melcarne, A; Broggi, G; Pluchino, F

    1988-01-01

    The surgical approach to cerebral giant aneurysms is still a source of great concern. We describe our experience with giant aneurysms of the anterior circulation and discuss the different surgical techniques adopted. During the period January 1972-December 1985, a total of 33 patients were operated upon at the Istituto Neurologico "C. Besta" of Milan for a giant aneurysm of the anterior circulation. Nineteen cases had suffered subarachnoid haemorrhage before admission; in 14 cases the hospitalization was due to evidence of mass effect on the surrounding neurovascular structures. All aneurysms were directly approached: in 24 cases the neck was occluded by a suitable clip, in 4 cases intramural thrombosis was attempted, in 3 cases the aneurysms were definitively trapped and in one case aneurysmorrhaphy was performed after resection of the sac. Operative mortality was 12%. Long-term follow-up shows good results whenever exclusion of the aneurysm from cerebral circulation had been achieved, either after removal of the sac or not; on the contrary, only fair or poor results were evident when other surgical techniques were adopted, either electively or out of necessity. The importance of intraoperative protection and monitoring of brain function is stressed.

  17. [Preparation of simulate craniocerebral models via three dimensional printing technique].

    PubMed

    Lan, Q; Chen, A L; Zhang, T; Zhu, Q; Xu, T

    2016-08-09

    Three dimensional (3D) printing technique was used to prepare the simulate craniocerebral models, which were applied to preoperative planning and surgical simulation. The image data was collected from PACS system. Image data of skull bone, brain tissue and tumors, cerebral arteries and aneurysms, and functional regions and relative neural tracts of the brain were extracted from thin slice scan (slice thickness 0.5 mm) of computed tomography (CT), magnetic resonance imaging (MRI, slice thickness 1mm), computed tomography angiography (CTA), and functional magnetic resonance imaging (fMRI) data, respectively. MIMICS software was applied to reconstruct colored virtual models by identifying and differentiating tissues according to their gray scales. Then the colored virtual models were submitted to 3D printer which produced life-sized craniocerebral models for surgical planning and surgical simulation. 3D printing craniocerebral models allowed neurosurgeons to perform complex procedures in specific clinical cases though detailed surgical planning. It offered great convenience for evaluating the size of spatial fissure of sellar region before surgery, which helped to optimize surgical approach planning. These 3D models also provided detailed information about the location of aneurysms and their parent arteries, which helped surgeons to choose appropriate aneurismal clips, as well as perform surgical simulation. The models further gave clear indications of depth and extent of tumors and their relationship to eloquent cortical areas and adjacent neural tracts, which were able to avoid surgical damaging of important neural structures. As a novel and promising technique, the application of 3D printing craniocerebral models could improve the surgical planning by converting virtual visualization into real life-sized models.It also contributes to functional anatomy study.

  18. SUPRAPUBIC LAPAROSCOPIC CHOLECYSTECTOMY: TECHNIQUE AND PRELIMINARY RESULTS

    PubMed Central

    SALES, Leonardo Adolpho S.; PINTO, João Odilo G.; QUEIROZ, Carlos Eduardo F.; CASTRO, Marcelo; DOURADO, Paulo Henrique F.; PINHEIRO, Fernando Antonio S.

    2014-01-01

    Background The minimally invasive abdominal surgery has evolved to reduce portals, culminating with a single incision and natural orifice operation. However, these methods are still expensive, difficult to implement and with questionable aesthetic results. Aim To present the standardization and preliminary results of a technique for performing laparoscopic suprapubic access by the principle which was called the Supra Pubic Endoscopic Surgery for cholecystectomy. Method The average body mass index of patients, the mean operative time, clinical data of the postoperative complications and quality of life were prospectively studied. The operation incisions consisted of: A) umbilical for instrumental dissection and clipping; B) in the right groin for handling and gallbladder gripping; C) suprapubic for the camera. With the patient in reverse Trendelenburg and left lateral decubitus, the operation flew by the camera trocar in C, proceeding with dissection and isolation of the biliary pedicle, identification of cystic duct and artery, with usual instrumentation. Transcystic intraoperative cholangiography was performed in all cases in which there were indications. The procedure was completed with clipping and sectioning of the cystic duct and artery, retrograde resection of the gallbladder and extracting it by the umbilical trocar incision under direct vision. Results Thirty patients undergone this surgical procedure between March and June 2012 and were evaluated. The mean age was 40.7 years and the indications were typical biliary colic in 18 cases (60 %), cholecystitis in five cases (16.6 %), biliary pancreatitis in one case (3.3%); polyp in three cases (10%) and obstructive jaundice at three cases (10%). The average body mass index was 27.8 (23.1-35.1) and surgical time ranged between 24 and 70 minutes. Conclusion The technique proved to be feasible and safe , with no significant complications, and satisfactory cosmetic results. PMID:24676293

  19. A clip-based protocol for breast boost radiotherapy provides clear target visualisation and demonstrates significant volume reduction over time

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lewis, Lorraine; Cox, Jennifer; Faculty of Health Sciences, University of Sydney, Sydney, New South Wales

    2015-09-15

    The clinical target volume (CTV) for early stage breast cancer is difficult to clearly identify on planning computed tomography (CT) scans. Surgical clips inserted around the tumour bed should help to identify the CTV, particularly if the seroma has been reabsorbed, and enable tracking of CTV changes over time. A surgical clip-based CTV delineation protocol was introduced. CTV visibility and its post-operative shrinkage pattern were assessed. The subjects were 27 early stage breast cancer patients receiving post-operative radiotherapy alone and 15 receiving post-operative chemotherapy followed by radiotherapy. The radiotherapy alone (RT/alone) group received a CT scan at median 25 daysmore » post-operatively (CT1rt) and another at 40 Gy, median 68 days (CT2rt). The chemotherapy/RT group (chemo/RT) received a CT scan at median 18 days post-operatively (CT1ch), a planning CT scan at median 126 days (CT2ch), and another at 40 Gy (CT3ch). There was no significant difference (P = 0.08) between the initial mean CTV for each cohort. The RT/alone cohort showed significant CTV volume reduction of 38.4% (P = 0.01) at 40 Gy. The Chemo/RT cohort had significantly reduced volumes between CT1ch: median 54 cm{sup 3} (4–118) and CT2ch: median 16 cm{sup 3}, (2–99), (P = 0.01), but no significant volume reduction thereafter. Surgical clips enable localisation of the post-surgical seroma for radiotherapy targeting. Most seroma shrinkage occurs early, enabling CT treatment planning to take place at 7 weeks, which is within the 9 weeks recommended to limit disease recurrence.« less

  20. Microsurgical Clipping of an Anterior Communicating Artery Aneurysm Using a Novel Robotic Visualization Tool in Lieu of the Binocular Operating Microscope: Operative Video.

    PubMed

    Klinger, Daniel R; Reinard, Kevin A; Ajayi, Olaide O; Delashaw, Johnny B

    2018-01-01

    The binocular operating microscope has been the visualization instrument of choice for microsurgical clipping of intracranial aneurysms for many decades. To discuss recent technological advances that have provided novel visualization tools, which may prove to be superior to the binocular operating microscope in many regards. We present an operative video and our operative experience with the BrightMatterTM Servo System (Synaptive Medical, Toronto, Ontario, Canada) during the microsurgical clipping of an anterior communicating artery aneurysm. To the best of our knowledge, the use of this device for the microsurgical clipping of an intracranial aneurysm has never been described in the literature. The BrightMatterTM Servo System (Synaptive Medical) is a surgical exoscope which avoids many of the ergonomic constraints of the binocular operating microscope, but is associated with a steep learning curve. The BrightMatterTM Servo System (Synaptive Medical) is a maneuverable surgical exoscope that is positioned with a directional aiming device and a surgeon-controlled foot pedal. While utilizing this device comes with a steep learning curve typical of any new technology, the BrightMatterTM Servo System (Synaptive Medical) has several advantages over the conventional surgical microscope, which include a relatively unobstructed surgical field, provision of high-definition images, and visualization of difficult angles/trajectories. This device can easily be utilized as a visualization tool for a variety of cranial and spinal procedures in lieu of the binocular operating microscope. We anticipate that this technology will soon become an integral part of the neurosurgeon's armamentarium. Copyright © 2017 by the Congress of Neurological Surgeons

  1. Retzus-sparing robotic-assisted laparoscopic radical prostatectomy: a step-by-step technique description of this first brazilian experience.

    PubMed

    Tobias-Machado, Marcos; Nunes-Silva, Igor; Hidaka, Alexandre Kiyoshi; Sato, Leticia Lumy Kanawa; Almeida, Roberto; Colombo, Jose Roberto; Zampolli, Hamilton de Campos; Pompeo, Antonio Carlos Lima

    2016-01-01

    Retzus-sparing robotic-assisted radical prostatectomy(RARP) is a newly approach that preserve the Retzus structures and provide better recovery of continence and erectile function. In Brazil, this approach has not yet been pre¬viously reported. Our goal is to describe Step-by-Step the Retzus-sparing RARP surgical technique and report our first Brazilian experience. We present a case of a 60-year-old white man with low risk prostate cancer. Surgical materials were four arms Da Vinci robotic platform system, six transperitoneal portals, two prolene wires and Polymer Clips. This surgical tech¬nique was step-by-step described according to Galfano et al. One additional step was added as a modification of Galfano et al. Primary technique description: The closure of the Denovellier fascia. We have operated one patient with this technique. The operative time was 180minutes, console time was135 min, the blood loss was 150ml, none perioperative or postoperative complications was found, hospital stay of 01 day. The anatomopathological classification revealed a pT2aN0M0 specimen with free surgical margins. The patient achieved continence immediately after bladder stent retrieval. Full erection reported after 30 days of surgery. Retzus-sparing RARP approach is feasible and reproducible. However, further comparative studies are neces¬sary to demonstrate potential benefits in continence and sexual outcomes over the standard approaches. Copyright® by the International Brazilian Journal of Urology.

  2. Comparison of Intraoperative Indocyanine Green Angiography and Digital Subtraction Angiography for Clipping of Intracranial Aneurysms

    PubMed Central

    Doss, Vinodh T.; Goyal, Nitin; Humphries, William; Hoit, Dan; Arthur, Adam; Elijovich, Lucas

    2015-01-01

    Background Residual aneurysm after microsurgical clipping carries a risk of aneurysm growth and rupture. Digital subtraction angiography (DSA) remains the standard to determine the adequacy of clipping. Intraoperative indocyanine green (ICG) angiography is increasingly utilized to confirm optimal clip positioning across the neck and to evaluate the adjacent vasculature. Objective We evaluated the correlation between ICG and DSA in clipped intracranial aneurysms. Methods A retrospective study of patients who underwent craniotomy and microsurgical clipping of intracranial aneurysms with ICG for 2 years. Patient characteristics, presentation details, operative reports, and pre- and postclipping angiographic images were reviewed to determine the adequacy of the clipping. Results Forty-seven patients underwent clipping with ICG and postoperative DSA: 57 aneurysms were clipped; 23 patients (48.9%) presented with subarachnoid hemorrhage. Nine aneurysms demonstrated a residual on DSA not identified on ICG (residual sizes ranged from 0.5 to 4.3 mm; average size: 1.8 mm). Postoperative DSA demonstrated no branch occlusions. Conclusion Intraoperative ICG is useful in the clipping of intracranial aneurysms to ensure a gross patency of branch vessels; however, the presence of residual aneurysms and subtle changes in flow in branch vessels is best seen by DSA. This has important clinical implications with regard to follow-up imaging and surgical/endovascular management. PMID:26279659

  3. Vascular closure staples-a new technique for biliary reconstruction: prospective randomized comparison with manual suture in an animal model.

    PubMed

    Birth, Matthias; Markert, Uwe; Strik, Martin; Wohlschläger, Charlotte; Brugmans, Frederik; Gerberding, Jürgen; Bruch, Hans P

    2002-01-15

    In orthotopic liver transplantation the incidence of biliary complications is up to 49%. In view of the relative frequency of such complications despite seemingly good preconditions, method-related disadvantages of conventional suture must also be considered as a possible cause. These include perforating needle injury of the choledochal wall with at least temporary exposure of suture material in the lumen, suboptimal approximation of the mucosa, and an additional decrease in blood flow in the choledochal stumps as a result of suture-related tissue strangulation. Hence the search for alternative anastomosis techniques. To evaluate the surgical suitability of extramucosal titanium clips (Vascular Closure Staples; VCS) in comparison with conventional manual suture, a study was performed in 36 pigs, which were randomly assigned to 4 groups, each containing 9 animals. Choledochal excision was performed in 18 pigs and transection in the other 18 pigs; end-to-end anastomosis was then carried out, using a VCS stapler in half of the animals in each of these two groups and conventional manual suture in the other half. Pre- and postanastomotic blood flow was measured during the surgery with the aid of a laser Doppler flow meter. The long-term behavior of the closure techniques was ascertained by regular laboratory checks over the ensuing 6-month observation period, after which the pigs were killed so that the specimens could be harvested. Using medium-sized VCS clips, we were able to create a tension-free, everted biliary anastomosis with exact mucosal approximation and no narrowing of the lumen, and without any technical problems during the performance of the procedure. Measurements with the laser Doppler flow meter showed well-preserved anastomotic blood flow after clip reconstruction, with significantly higher perfusion values than after manual suture. The postoperative courses of the investigated laboratory parameters did not reveal any significant differences between the two methods. In contrast, histomorphometric evaluation showed wall thickness and thus fibrosis in the anastomosis region to be less in the clip group than in the suture group (median: 510 microm versus 660 microm, P<0.001). In the pigs in which clip anastomosis was used, there were no detectable anastomotic stenoses; in the pigs in which conventional suture was used, however, ultrasonography revealed five anastomoses with varying degrees of narrowing. Extramucosal VCS clip anastomosis not only offers potential advantages with respect to nonpenetrating and optimal mucosal contact, investigations in animals also show it to be superior to conventional manual suture as regards anastomotic blood flow and medium-term fibrosis formation. We believe that our data and the available literature warrant a clinical evaluation of this technique in appropriate studies.

  4. Suture retraction technique to prevent parent vessel obstruction following aneurysm tandem clipping.

    PubMed

    Rayan, Tarek; Amin-Hanjani, Sepideh

    2015-08-01

    With large or giant aneurysms, the use of multiple tandem clips can be essential for complete obliteration of the aneurysm. One potential disadvantage, however, is the considerable cumulative weight of these clips, which may lead to kinking of the underlying parent vessels and obstruction of flow. The authors describe a simple technique to address this problem, guided by intraoperative blood flow measurements, in a patient with a ruptured near-giant 2.2 × 1.7-cm middle cerebral artery bifurcation aneurysm that was treated with the tandem clipping technique. A total of 11 clips were applied in a vertical stacked fashion. The cumulative weight of the clips caused kinking of the temporal M2 branch of the bifurcation with reduction of flow. A 4-0 Nurolon suture tie was applied to the hub of one of the clips and was tethered to the dura of the sphenoid ridge by a small mini-clip and reinforced by application of tissue sealant. The patient underwent intraoperative indocyanine green videoangiography as well as catheter angiography, which demonstrated complete aneurysmal obliteration and preservation of vessel branches. Postoperative angiography confirmed patency of the bifurcation vessels with mild vasospasm. The patient had a full recovery with no postoperative complications and was neurologically intact at her 6-month follow-up. The suture retraction technique allows a simple solution to parent vessel obstruction following aneurysm tandem clipping, in conjunction with the essential guidance provided by intraoperative flow measurements.

  5. Image Guidance in External Beam Accelerated Partial Breast Irradiation: Comparison of Surrogates for the Lumpectomy Cavity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hasan, Yasmin; Kim, Leonard; Martinez, Alvaro

    Purpose: To compare localization of the lumpectomy cavity by using breast surface matching vs. clips for image-guided external beam accelerated partial breast irradiation. Methods and Materials: Twenty-seven patients with breast cancer with two computed tomography (CT) scans each had three CT registrations performed: (1) to bony anatomy, (2) to the center of mass (COM) of surgical clips, and (3) to the breast surface. The cavity COM was defined in both the initial and second CT scans after each type of registration, and distances between COMs ({delta}COM{sub Bone}, {delta}COM{sub Clips}, and {delta}COM{sub Surface}) were determined. Smaller {delta}COMs were interpreted as bettermore » localizations. Correlation coefficients were calculated for {delta}COM vs. several variables. Results: The {delta}COM{sub Bone} (mean, 7 {+-} 2 [SD] mm) increased with breast volume (r = 0.4; p = 0.02) and distance from the chest wall (r = 0.5; p = 0.003). Relative to bony registration, clip registration provided better localization ({delta}COM{sub Clips} < {delta}COM{sub Bone}) in 25 of 27 cases. Breast surface matching improved cavity localization ({delta}COM{sub Surface} < {delta}COM{sub Bone}) in 19 of 27 cases. Mean improvements ({delta}COM{sub Bone} - {delta}COM{sub ClipsorSurface}) were 4 {+-} 3 and 2 {+-} 4 mm, respectively. In terms of percentage of improvement ([{delta}COM{sub Bone} - {delta}COM{sub ClipsorSurface}]/{delta}COM{sub Bone}), only surface matching showed a correlation with breast volume. Clip localization outperformed surface registration for cavities located superior to the breast COM. Conclusions: Use of either breast surface or surgical clips as surrogates for the cavity results in improved localization in most patients compared with bony registration and may allow smaller planning target volume margins for external beam accelerated partial breast irradiation. Compared with surface registration, clip registration may be less sensitive to anatomic characteristics and therefore more broadly applicable.« less

  6. Natural orifice transluminal endoscopic surgery gastrotomy closure with an over-the-endoscope clip: a randomized, controlled porcine study (with videos).

    PubMed

    von Renteln, Daniel; Schmidt, Arthur; Vassiliou, Melina C; Gieselmann, Maria; Caca, Karel

    2009-10-01

    Secure endoscopic closure of transgastric natural orifice transluminal endoscopic surgery (NOTES) access is of paramount importance. The over-the-scope clip (OTSC) system has previously been shown to be effective for NOTES gastrotomy closure. To compare OTSC gastrotomy closure with surgical closure. Randomized, controlled animal study. Animal facility laboratory. Thirty-six female domestic pigs. Gastrotomies were created by using a needle-knife and an 18-mm balloon. The animals were subsequently randomized to either open surgical repair with interrupted sutures or endoscopic repair with 12-mm OTSCs. In addition, pressurized leak tests were performed in ex vivo specimens of 18-mm scalpel incisions closed with suture (n = 14) and of intact stomachs (n = 10). The mean time for endoscopic closure was 9.8 minutes (range 3-22, SD 5.5). No complications occurred during either type of gastrotomy closure. At necropsy, examination of all OTSC and surgical closures demonstrated complete sealing of gastrotomy sites without evidence of injury to adjacent organs. Pressurized leak tests showed a mean burst pressure of 83 mm Hg (range 30-140, SD 27) for OTSC closures and 67 mm Hg (range 30-130, SD 27.7) for surgical sutures. Ex vivo hand-sewn sutures of 18-mm gastrotomies (n = 14) exhibited a mean burst pressure of 65 mm Hg (range 20-140, SD 31) and intact ex vivo stomachs (n = 10) had a mean burst pressure of 126 mm Hg (range 90-170, SD 28). The burst pressure of ex vivo intact stomachs was significantly higher compared with OTSC closures (P < .01), in vivo surgical closures (P < .01), and ex vivo hand-sewn closures (P < .01). There was a trend toward higher burst pressures in the OTSC closures compared with surgical closures (P = .063) and ex vivo hand-sewn closures (P = .094). In vivo surgical closures demonstrated similar burst pressures compared with ex vivo hand-sewn closures (P = .848). Nonsurvival setting. Endoscopic closure by using the OTSC system is comparable to surgical closure in a nonsurvival porcine model. This technique is easy to perform and is suitable for NOTES gastrotomy closure.

  7. Non-Exposure, Device-Assisted Endoscopic Full-thickness Resection.

    PubMed

    Bauder, Markus; Schmidt, Arthur; Caca, Karel

    2016-04-01

    Recent developments have expanded the frontier of interventional endoscopy toward more extended resections following surgical principles. This article presents two new device-assisted techniques for endoscopic full-thickness resection in the upper and lower gastrointestinal tract. Both methods are nonexposure techniques avoiding exposure of gastrointestinal contents to the peritoneal cavity by a "close first-cut later" principle. The full-thickness resection device is a novel over-the-scope device designed for clip-assisted full-thickness resection of colorectal lesions. Endoscopic full-thickness resection of gastric subepithelial tumors can be performed after placing transmural sutures underneath the tumor with a suturing device originally designed for endoscopic antireflux therapy. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. Comparison of holding strength of suture anchors for hepatic and renal parenchyma.

    PubMed

    Ames, Caroline D; Perrone, Juan M; Frisella, Alison J; Morrissey, Kevin; Landman, Jaime

    2005-12-01

    Various laparoscopic devices have been described for suture anchoring during solidorgan parenchymal closure. Application of these devices expedites the closure of parenchymal defects and minimizes ischemia time. We compared different technologies as suture anchors for parenchymal closure. A tensometer was used to determine the amount of tension necessary to dislodge each of five different clips from Vicryl suture alone or against two different substrates (fresh pig kidney and liver) with and without an intervening pledget. The clips investigated were the Lapra-Ty (Ethicon), Endoclip II (US Surgical), small Horizon Ligating Clips (Weck), Hem-o-lok Medium Polymer Clips (Week), and a novel Suture-clip (Applied Medical). ANOVA and two-sided Fisher's exact test provided statistical analysis. The force required to dislodge the Lapra-Ty clip from bare suture for both 0 and 1 Vicryl (7.0 N) was approximately fourfold the force required to dislodge the Endoclips or the 5-mm or 10-mm Hem-o-lok clips (p<0.01). When clips were applied to suture running through renal or liver parenchyma, the novel Suture-clip required the greatest tension to dislodge (P<0.01), followed by the Horizon and Lapra-Ty clips. There were no statistically significant differences in the tension required to dislodge a given clip from the two parenchymal substrates or in the presence or absence of a pledget. In our experimental model, the Suture-clip, Lapra-Ty, and Horizon clips required significantly greater tension to dislodge than the Hem-o-lok and Endoclip clips. The addition of a pledget did not improve tension resistance.

  9. History, Evolution, and Continuing Innovations of Intracranial Aneurysm Surgery.

    PubMed

    Lai, Leon T; O'Neill, Anthea H

    2017-06-01

    Evolution in the surgical treatment of intracranial aneurysms is driven by the need to refine and innovate. From an early application of the Hunterian carotid ligation to modern-day sophisticated aneurysm clip designs, progress has been made through dedication and technical maturation of cerebrovascular neurosurgeons to overcome challenges in their practices. The global expansion of endovascular services has challenged the existence of aneurysm surgery, changing the complexity of the aneurysm case mix and volume that are referred for surgical repair. Concepts of how to best treat intracranial aneurysms have evolved over generations and will continue to do so with further technological innovations. As with the evolution of any type of surgery, innovations frequently arise from the criticism of current techniques. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. From tricuspid to double orifice Morphology: Percutaneous tricuspid regurgitation repair with the MitraClip device in congenitally corrected-transposition of great arteries.

    PubMed

    Picard, Fabien; Tadros, Victor-Xavier; Asgar, Anita W

    2017-09-01

    Edge to edge transcatheter mitral valve repair with MitraClip (Abbott Vascular, Menlo Park, CA) is increasing for high-risk surgical patients with significant mitral regurgitation. Patients with congenitally corrected transposition of the great arteries (CCTGA) presenting with tricuspid valve regurgitation of a systemic right ventricle may represent particularly challenging candidates for MitraClip given their anatomy. We report the case of a 67-year-old gentleman with CCTGA and severe tricuspid regurgitation who was referred for MitraClip implantation after heart team consensus. Successful implantation of one clip was performed, achieving a significant reduction of the regurgitation. Similarly, favorable findings were confirmed at 6 months, 1 and 2 years follow-up and the patient had no recurrent heart failure admissions after 2-year follow-up. We describe the technical considerations and the importance of 3D-transoesophageal echocardiography for performing the MitraClip of a trileaflet systemic atrioventricular valve. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  11. Macrovascular Decompression of the Brainstem and Cranial Nerves: Evolution of an Anteromedial Vertebrobasilar Artery Transposition Technique.

    PubMed

    Choudhri, Omar; Connolly, Ian D; Lawton, Michael T

    2017-08-01

    Tortuous and dolichoectatic vertebrobasilar arteries can impinge on the brainstem and cranial nerves to cause compression syndromes. Transposition techniques are often required to decompress the brainstem with dolichoectatic pathology. We describe our evolution of an anteromedial transposition technique and its efficacy in decompressing the brainstem and relieving symptoms. To present the anteromedial vertebrobasilar artery transposition technique for macrovascular decompression of the brainstem and cranial nerves. All patients who underwent vertebrobasilar artery transposition were identified from the prospectively maintained database of the Vascular Neurosurgery service, and their medical records were reviewed retrospectively. The extent of arterial displacement was measured pre- and postoperatively on imaging. Vertebrobasilar arterial transposition and macrovascular decompression was performed in 12 patients. Evolution in technique was characterized by gradual preference for the far-lateral approach, use of a sling technique with muslin wrap, and an anteromedial direction of pull on the vertebrobasilar artery with clip-assisted tethering to the clival dura. With this technique, mean lateral displacement decreased from 6.6 mm in the first half of the series to 3.8 mm in the last half of the series, and mean anterior displacement increased from 0.8 to 2.5 mm, with corresponding increases in satisfaction and relief of symptoms. Compressive dolichoectatic pathology directed laterally into cranial nerves and posteriorly into the brainstem can be corrected with anteromedial transposition towards the clivus. Our technique accomplishes this anteromedial transposition from an inferolateral surgical approach through the vagoaccessory triangle, with sling fixation to clival dura using aneurysm clips. Copyright © 2017 by the Congress of Neurological Surgeons

  12. Use of pneumocystoplasty for overinflation of the swim bladder in a goldfish.

    PubMed

    Britt, Tara; Weisse, Chick; Weber, E Scott; Matzkin, Zach; Klide, Alan

    2002-09-01

    A Ryukin goldfish was evaluated because of a 6-month history of progressive abdominal distention and positive buoyancy. Overinflation of the swim bladder was diagnosed, and the fish was anesthetized with tricaine methanesulfonate. Archimedes' principle was used to determine the volume of swim bladder that was removed surgically. The caudal swim bladder was exteriorized through an abdominal incision and 2 surgical clips were placed across it to limit its size. After surgery, the fish remained in a state of negative buoyancy in sternal and lateral recumbency on the bottom of the tank. Sutures were removed 15 days after surgery, but the fish died 24 days after surgery. A full necropsy could not be performed because of autolysis of the tissues, but the surgical clips and the swim bladder appeared unremarkable. Pneumocystoplasty may be a viable treatment for this condition.

  13. Unruptured cerebral aneurysm clipping: the association of combined open and endovascular expertise with outcomes

    PubMed Central

    Bekelis, Kimon; Gottlieb, Dan; Bovis, George; Su, Yin; Tjoumakaris, Stavropoula; Jabbour, Pascal; MacKenzie, Todd A.

    2017-01-01

    Background It is often questioned if one physician can conduct both open and endovascular techniques successfully and safely. We investigated the association of combined open and endovascular expertise with the outcomes of unruptured cerebral aneurysm clipping. Methods We performed a cohort study of 100% of Medicare fee-for-service claims data for elderly patients who underwent surgical clipping for unruptured cerebral aneurysms from 2007 to 2012. In order to control for confounding we used propensity score conditioning, and controlled for clustering at the physician level. Results During the study period, there were 3,247 patients, who underwent clipping for unruptured cerebral aneurysms, and met the inclusion criteria. Of these, 766 (23.6%) underwent treatment by hybrid neurosurgeons, and 2,481 (76.4%) by proceduralists who performed only clipping. Multivariable regression analysis with propensity score adjustment demonstrated lack of association of combined practice with 1-year postoperative mortality (OR, 0.81; 95% CI, 0.51–1.28), discharge to rehabilitation (OR, 0.95; 95% CI, 0.72–1.25), LOS (adjusted difference 0.85 days; 95% CI, −0.31 to 2.00), or 30-day readmission rate (OR, 1.05; 95% CI, 0.80–1.39). Higher procedural volume was independently associated with improved outcomes. Conclusions In a cohort of Medicare patients with unruptured aneurysms, we did not demonstrate a difference in mortality, discharge to rehabilitation, or readmission rate between hybrid neurosurgeons and surgeons only performing clipping. Funding Supported by grants from the National Institute on Aging (PO1- AG19783), and the National Institutes of Health (NIH) Common Fund (U01-AG046830) and the National Center for Advancing Translational Sciences (NCATS) of the NIH (Dartmouth Clinical and Translational Science Institute-UL1TR001086). The funders had no role in the design or execution of the study. PMID:26385788

  14. Dual-Channel Endoscopic Indocyanine Green Fluorescence Angiography for Clipping of Cerebral Aneurysms.

    PubMed

    Cho, Won-Sang; Kim, Jeong Eun; Kang, Hyun-Seung; Ha, Eun Jin; Jung, Minwoong; Lee, Choonghee; Shin, Il Hyung; Kang, Uk

    2017-04-01

    Neuroendoscopy is useful for assessing status of perforators, parent arteries, and aneurysms beyond the straight line of microscopic view during aneurysm clipping. We aimed to evaluate the clinical usefulness of our endoscopic indocyanine green angiography (ICGA) system, which can simultaneously display visible light and indocyanine green fluorescent images. Surgical clipping of 16 unruptured aneurysms in 10 patients was performed via the keyhole approach. Using our endoscopic ICGA and commercial microscopic ICGA systems, we prospectively compared 10 targeted cerebral aneurysms at the posterior communicating (n = 4) and anterior choroidal (n = 6) arteries. Microscopic ICGA and endoscopic ICGA were feasible during surgery. Microscopic ICGA displayed 50% of branch orifices, 100% of branch trunks, and 20% of exact clip positions, whereas endoscopic ICGA showed 100% of these. Based on endoscopic ICGA findings such as incomplete clipping and compromise of parent arteries or branches, clips were repositioned in 2 cases, and additional clips were applied in 2 cases. Complete occlusion and residual neck states were achieved in 6 and 4 aneurysms after surgery. There were no neurologic deficits within 3 months after surgery except for frontalis palsy and anosmia in each patient. The endoscopic ICGA system with dual imaging of visible light and indocyanine green fluorescence was very useful for assessing geometry of aneurysms and surrounding vessels before clipping and for evaluating completeness of clip position after clipping. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Do You See What I See? How We Use Video as an Adjunct to General Surgery Resident Education.

    PubMed

    Abdelsattar, Jad M; Pandian, T K; Finnesgard, Eric J; El Khatib, Moustafa M; Rowse, Phillip G; Buckarma, EeeL N H; Gas, Becca L; Heller, Stephanie F; Farley, David R

    2015-01-01

    Preparation of learners for surgical operations varies by institution, surgeon staff, and the trainees themselves. Often the operative environment is overwhelming for surgical trainees and the educational experience is substandard due to inadequate preparation. We sought to develop a simple, quick, and interactive tool that might assess each individual trainee's knowledge baseline before participating in minimally invasive surgery (MIS). A 4-minute video with 5 separate muted clips from laparoscopic procedures (splenectomy, gastric band removal, cholecystectomy, adrenalectomy, and inguinal hernia repair) was created and shown to medical students (MS), general surgery residents, and staff surgeons. Participants were asked to watch the video and commentate (provide facts) on the operation, body region, instruments, anatomy, pathology, and surgical technique. Comments were scored using a 100-point grading scale (100 facts agreed upon by 8 surgical staff and trainees) with points deducted for incorrect answers. All participants were video recorded. Performance was scored by 2 separate raters. An academic medical center. MS = 10, interns (n = 8), postgraduate year 2 residents (PGY)2s (n = 11), PGY3s (n = 10), PGY4s (n = 9), PGY5s (n = 7), and general surgery staff surgeons (n = 5). Scores ranged from -5 to 76 total facts offered during the 4-minute video examination. MS scored the lowest (mean, range; 5, -5 to 8); interns were better (17, 4-29), followed by PGY2s (31, 21-34), PGY3s (33, 10-44), PGY4s (44, 19-47), PGY5s (48, 28-49), and staff (48, 17-76), p < 0.001. Rater concordance was 0.98-measured using a concordance correlation coefficient (95% CI: 0.96-0.99). Only 2 of 8 interns acknowledged the critical view during the laparoscopic cholecystectomy video clip vs 10 of 11 PGY2 residents (p < 0.003). Of 8 interns, 7 misperceived the spleen as the liver in the splenectomy clip vs 2 of 7 chief residents (p = 0.02). Not surprisingly, more experienced surgeons were able to relay a larger number of laparoscopic facts during a 4-minute video clip of 5 MIS operations than inexperienced trainees. However, even tenured staff surgeons relayed very few facts on procedures they were unfamiliar with. The potential differentiating capabilities of such a quick and inexpensive effort has pushed us to generate better online learning tools (operative modules) and hands-on simulation resources for our learners. We aim to repeat this and other studies to see if our learners are better prepared for video assessment and ultimately, MIS operations. Copyright © 2015 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  16. Importance of nasal clipping in screening investigations of flow volume curve.

    PubMed

    Yanev, I

    1992-01-01

    Comparative analysis of some basic lung indices obtained from a screening investigation of the flow volume curve by using two techniques, with a nose clip and without a nose clip, was made on a cohort of 86 workers in a factory shop for the production of bearings. We found no statistically significant differences between the indices obtained by the two techniques. Our study showed that the FVC and FEV1 obtained in workers without using nose clips were equal to or better than those obtained using nose clips in 60% of the workers. The reproducibility of the two methods was similar. The analysis of the data has shown that the flow volume curve investigation gives better results when performed without a nose clip, especially in industrial conditions.

  17. The influence of the different forms of appendix base closure on patient outcome in laparoscopic appendectomy: a randomized trial.

    PubMed

    Delibegović, Samir; Mehmedovic, Zlatan

    2018-05-01

    During laparoscopic appendectomy, the base of the appendix is usually secured by loop ligature or stapling device. Hem-o-lok and DS clips have been shown as alternative techniques. The aim of this study was to compare the clinical outcomes of various forms of securing the base of the appendix, in order to find the most suitable method. The study included 120 patients with acute appendicitis randomly divided into four groups with 30 patients in each. In the first group, the base of the appendix was secured using an Endoloop, in the second group using a stapling device, in the third group using Hem-o-lok, and in the fourth group using a DS clip. The primary outcome was overall morbidity following securing the base of the appendix. Secondary outcomes were time of application and operative procedure, total length of stay, and surgical outcome. No morbidity was recorded in any group. The time of application was significantly longer in the Endoloop group than in the Stapler (P < 0.0001), Hem-o-lok (P < 0.0001), and DS clips (P < 0.0001) groups. The time of application in the Stapler group was significantly shorter than in the Hem-o-lok (P < 0.0001) and the DS clips (P < 0.0001) groups. The time of the operative procedure was significantly longer in the Endoloop than in the Stapler group (P < 0.0001). The time of the operative procedure in the Stapler group was significantly shorter than in the DS clips group (P < 0.0001) but did not differ significantly from the Hem-o-lok group (P = 0.199). The time of the operative procedure in the Hem-o-lok group was significantly shorter than in the DS clips group (P = 0.044). All forms of closure of the appendix base are acceptable, but Hem-o-lok and DS clips have the best potential for further development, and will probably become the method of choice in securing the base of the appendix.

  18. Long-term results of middle cerebral artery aneurysm clipping in the Barrow Ruptured Aneurysm Trial.

    PubMed

    Mooney, Michael A; Simon, Elias D; Brigeman, Scott; Nakaji, Peter; Zabramski, Joseph M; Lawton, Michael T; Spetzler, Robert F

    2018-04-27

    OBJECTIVE A direct comparison of endovascular versus microsurgical treatment of ruptured middle cerebral artery (MCA) aneurysms in randomized trials is lacking. As endovascular treatment strategies continue to evolve, the number of reports of endovascular treatment of these lesions is increasing. Herein, the authors report a detailed post hoc analysis of ruptured MCA aneurysms treated by microsurgical clipping from the Barrow Ruptured Aneurysm Trial (BRAT). METHODS The cases of patients enrolled in the BRAT who underwent microsurgical clipping for a ruptured MCA aneurysm were reviewed. Characteristics of patients and their clinical outcomes and long-term angiographic results were analyzed. RESULTS Fifty patients underwent microsurgical clipping of a ruptured MCA aneurysm in the BRAT, including 21 who crossed over from the endovascular treatment arm. Four patients with nonsaccular (e.g., dissecting, fusiform, or blister) aneurysms were excluded, leaving 46 patients for analysis. Most (n = 32; 70%) patients presented with a Hunt and Hess grade II or III subarachnoid hemorrhage, with a high prevalence of intraparenchymal blood (n = 23; 50%), intraventricular blood (n = 21; 46%), or both. At the last follow-up (up to 6 years after treatment), clinical outcomes were good (modified Rankin Scale score 0-2) in 70% (n = 19) of 27 Hunt and Hess grades I-III patients and in 36% (n = 4) of 11 Hunt and Hess grade IV or V patients. There were no instances of rebleeding after the surgical clipping of aneurysms in this series at the time of last clinical follow-up. CONCLUSIONS Microsurgical clipping of ruptured MCA aneurysms has several advantages over endovascular treatment, including durability over time. The authors report detailed outcome data of patients with ruptured MCA aneurysms who underwent microsurgical clipping as part of a prospective, randomized trial. These results should be used for comparison with future endovascular and surgical series to ensure that the best results are being achieved for patients with ruptured MCA aneurysms.

  19. Comparison of clipping and coiling in elderly patients with unruptured cerebral aneurysms

    PubMed Central

    Bekelis, Kimon; Gottlieb, Daniel J.; Su, Yin; O’Malley, A. James; Labropoulos, Nicos; Goodney, Philip; Lawton, Michael T.; MacKenzie, Todd A.

    2016-01-01

    OBJECTIVE The comparative effectiveness of the 2 treatment options—surgical clipping and endovascular coiling—for unruptured cerebral aneurysms remains an issue of debate and has not been studied in clinical trials. The authors investigated the association between treatment method for unruptured cerebral aneurysms and outcomes in elderly patients. METHODS The authors performed a cohort study of 100% of Medicare fee-for-service claims data for elderly patients who had treatment for unruptured cerebral aneurysms between 2007 and 2012. To control for measured confounding, the authors used propensity score conditioning and inverse probability weighting with mixed effects to account for clustering at the level of the hospital referral region (HRR). An instrumental variable (regional rates of coiling) analysis was used to control for unmeasured confounding and to create pseudo-randomization on the treatment method. RESULTS During the study period, 8705 patients underwent treatment for unruptured cerebral aneurysms and met the study inclusion criteria. Of these patients, 2585 (29.7%) had surgical clipping and 6120 (70.3%) had endovascular coiling. Instrumental variable analysis demonstrated no difference between coiling and clipping in 1-year postoperative mortality (OR 1.25, 95% CI 0.68–2.31) or 90-day readmission rate (OR 1.04, 95% CI 0.66–1.62). However, clipping was associated with a greater likelihood of discharge to rehabilitation (OR 6.39, 95% CI 3.85–10.59) and 3.6 days longer length of stay (LOS; 95% CI 2.90–4.71). The same associations were present in propensity score–adjusted and inverse probability– weighted models. CONCLUSIONS In a cohort of Medicare patients, there was no difference in mortality and the readmission rate between clipping and coiling of unruptured cerebral aneurysms. Clipping was associated with a higher rate of discharge to a rehabilitation facility and a longer LOS. PMID:27203150

  20. Fast MRI-guided vacuum-assisted breast biopsy: initial experience.

    PubMed

    Liberman, Laura; Morris, Elizabeth A; Dershaw, D David; Thornton, Cynthia M; Van Zee, Kimberly J; Tan, Lee K

    2003-11-01

    The purpose of this study was to evaluate a new method for performing MRI-guided vacuum-assisted breast biopsy in a study of lesions that had subsequent surgical excision. SUBJECTS AND METHODS. Twenty women scheduled for MRI-guided needle localization and surgical biopsy were prospectively entered in the study. MRI-guided biopsy was performed with a vacuum-assisted probe, followed by placement of a localizing clip, and then needle localization for surgical excision. Vacuum-assisted biopsy and surgical histology were correlated. Vacuum-assisted biopsy was successfully performed in 19 (95%) of the 20 women. The median size of 27 MRI-detected lesions that had biopsy was 1.0 cm (range, 0.4-6.4 cm). Cancer was present in eight (30%) of 27 lesions and in six (32%) of 19 women; among these eight cancers, five were infiltrating and three were ductal carcinoma in situ (DCIS). Among these 27 lesions, histology was benign at vacuum-assisted biopsy and at surgery in 19 (70%), cancer at vacuum-assisted biopsy in six (22%), atypical ductal hyperplasia at vacuum-assisted biopsy and DCIS at surgery in one (4%), and benign at vacuum-assisted biopsy with surgery showing microscopic DCIS that was occult at MRI in one (4%). The median time to perform vacuum-assisted biopsy of a single lesion was 35 min (mean, 35 min; range, 24-48 min). Placement of a localizing clip, attempted in 26 lesions, was successful in 25 (96%) of 26, and the clip was retrieved on specimen radiography in 22 (96%) of 23. One complication occurred: a hematoma that resolved with compression. MRI-guided vacuum-assisted biopsy is a fast, safe, and accurate alternative to surgical biopsy for breast lesions detected on MRI.

  1. Recurrence of ICA-PCoA aneurysms after neck clipping.

    PubMed

    Sakaki, T; Takeshima, T; Tominaga, M; Hashimoto, H; Kawaguchi, S

    1994-01-01

    Between 1975 and 1992, 2211 patients underwent aneurysmal neck clipping at the Nara Medical University clinic and associated hospitals. The aneurysm in 931 of these patients was situated at the junction of the internal carotid artery (ICA) and posterior communicating artery (PCoA). Seven patients were readmitted 4 to 17 years after the first surgery because of regrowth and rupture of an ICA-PCoA aneurysmal sac that had arisen from the residual neck. On angiograms obtained following aneurysmal neck clipping, a large primitive type of PCoA was demonstrated in six patients and a small PCoA in one. A small residual aneurysm was confirmed in only two patients and angiographically complete neck clipping in five. Recurrent ICA-PCoA aneurysms were separated into two types based on the position of the old clip in relation to the new growth. Type 1 aneurysms regrow from the entire neck and balloon eccentrically. In this type, it is possible to apply the clip at the neck as in conventional clipping for a ruptured aneurysm. Type 2 includes aneurysms in which the proximal portion of a previous clip is situated at the corner of the ICA and aneurysmal neck and the distal portion on the enlarged dome of the aneurysm, because the sac is regrowing from a portion of the residual neck. In this type of aneurysm, a Sugita fenestrated clip can occlude the residual neck, overriding the old clip. Classifying these aneurysms into two groups is very useful from a surgical point of view because it is possible to apply a new clip without removing the old clip, which was found to be adherent to surrounding tissue.

  2. Film clips and narrative text as subjective emotion elicitation techniques.

    PubMed

    Zupan, Barbra; Babbage, Duncan R

    2017-01-01

    Film clips and narrative text are useful techniques in eliciting emotion in a laboratory setting but have not been examined side-by-side using the same methodology. This study examined the self-identification of emotions elicited by film clip and narrative text stimuli to confirm that selected stimuli appropriately target the intended emotions. Seventy participants viewed 30 film clips, and 40 additional participants read 30 narrative texts. Participants identified the emotion experienced (happy, sad, angry, fearful, neutral-six stimuli each). Eighty-five percent of participants self-identified the target emotion for at least two stimuli for all emotion categories of film clips, except angry (only one) and for all categories of narrative text, except fearful (only one). The most effective angry text was correctly identified 74% of the time. Film clips were more effective in eliciting all target emotions in participants for eliciting the correct emotion (angry), intensity rating (happy, sad), or both (fearful).

  3. Assessment of a simple, novel endoluminal method for gastrotomy closure in NOTES.

    PubMed

    Lee, Sang Soo; Oelschlager, Brant K; Wright, Andrew S; Soares, Renato V; Sinan, Huseyin; Montenovo, Martin I; Hwang, Joo Ha

    2011-10-01

    A reliable method for gastrotomy closure in NOTES will be essential for NOTES to become viable clinically. However, methods using existing and widely available endoscopic accessories have been ineffective. The objective of this study was to evaluate the feasibility and safety of a new simple method for gastric closure (retracted clip-assisted loop closure) that uses existing endoscopic accessories with minor modifications. The retracted clip-assisted loop closure technique involves deploying 3-4 Resolution(®) clips (modified by attaching a 90-cm length of suture to the end of each clip) along the margin of the gastrotomy with one jaw on the serosal surface and the other jaw on the mucosal surface. The suture strings are threaded through an endoloop. Traction is then applied to the strings causing the gastric wall to tent. The endoloop is secured below the tip of the clips, completing a full-thickness gastrotomy closure. The main outcome measures were feasibility, efficacy, and safety of the new retracted clip-assisted loop closure technique for NOTES gastrotomy closure. An air-tight seal was achieved in 100% (n = 9) of stomachs. The mean leak pressure was 116.3 (±19.4) mmHg. The retracted clip-assisted loop closure technique can be used to perform NOTES gastrotomy closure by using existing endoscopic accessories with minor modifications.

  4. CT-image-based conformal brachytherapy of breast cancer. The significance of semi-3-D and 3-D treatment planning.

    PubMed

    Polgár, C; Major, T; Somogyi, A; Takácsi-Nagy, Z; Mangel, L C; Forrai, G; Sulyok, Z; Fodor, J; Németh, G

    2000-03-01

    To compare the conventional 2-D, the simulator-guided semi-3-D and the recently developed CT-guided 3-D brachytherapy treatment planning in the interstitial radiotherapy of breast cancer. In 103 patients with T1-2, N0-1 breast cancer the tumor bed was clipped during breast conserving surgery. Fifty-two of them received boost brachytherapy after 46 to 50 Gy teletherapy and 51 patients were treated with brachytherapy alone via flexible implant tubes. Single, double and triple plane implant was used in 6, 89 and 8 cases, respectively. The dose of boost brachytherapy and sole brachytherapy prescribed to dose reference points was 3 times 4.75 Gy and 7 times 5.2 Gy, respectively. The positions of dose reference points varied according to the level (2-D, semi-3-D and 3-D) of treatment planning performed. The treatment planning was based on the 3-D reconstruction of the surgical clips, implant tubes and skin points. In all cases the implantations were planned with a semi-3-D technique aided by simulator. In 10 cases a recently developed CT-guided 3-D planning system was used. The semi-3-D and 3-D treatment plans were compared to hypothetical 2-D plans using dose-volume histograms and dose non-uniformity ratios. The values of mean central dose, mean skin dose, minimal clip dose, proportion of underdosaged clips and mean target surface dose were evaluated. The accuracy of tumor bed localization and the conformity of planning target volume and treated volume were also analyzed in each technique. With the help of conformal semi-3-D and 3-D brachytherapy planning we could define reference dose points, active source positions and dwell times individually. This technique decreased the mean skin dose with 22.2% and reduced the possibility of geographical miss. We could achieve the best conformity between the planning target volume and the treated volume with the CT-image based 3-D treatment planning, at the cost of worse dose homogeneity. The mean treated volume was reduced by 25.1% with semi-3-D planning, however, it was increased by 16.2% with 3-D planning, compared to the 2-D planning. The application of clips into the tumor bed and the conformal (semi-3-D and 3-D) planning help to avoid geographical miss. CT is suitable for 3-D brachytherapy planning. Better local control with less side effects might be achieved with these new techniques. Conformal 3-D brachytherapy calls for new treatment planning concepts, taking the irregular 3-D shape of the target volume into account. The routine clinical application of image-based 3-D brachytherapy is a real aim in the very close future.

  5. SU-E-J-201: Position Verification in Breast Cancer Radiotherapy Using Tantalum Clips in the Lumpectomy Cavity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Santvoort, J van; Van der Drift, M; Kuipers, J

    2014-06-01

    Purpose: To find out whether tantalum surgical clips can be used for online position verification in treatment of the lumpectomy cavity (LC) in breast cancer patients. Tantalum is a high density metal that could be visible on Electronic Portal Images (EPIs) and be an affordable alternative to gold markers. Clips are considered more representative for the LC position than nearby bony structures. Methods: In twelve patients the surgeon had placed 2 to 5 tantalum clips in the LC. The AP and lateral fields used for portal imaging, were adapted. In doing so, both bony structures and tantalum clips were visiblemore » on EPIs. The following analyses were performed:1. Image degradation, with respect to delineating the CTV, of the axial CT slices by artefacts because of the tantalum clips was evaluated by a radiation oncologist;2. The visibility of the tantalum clips on the EPIs was evaluated by four radiation therapists (RTTs);3. Bony anatomy and tantalum clip matches were performed on the same images independently by two observers. Results: 1. Delineation of the CTV by the radiation oncologist was not hampered by CT image artefacts because of the clips.2. The mean score for visibility of the clips on the EPIs, analysed by the four RTTs, was 5.6 on a scale of 10 (range 3.9 – 8.0).3. In total 12 patients with 16 fractions each were analysed. The differences between clip match and bone match are significant with a mean vector length of 5.2 mm (SD 1.9 mm) for the difference. Conclusion: Results of matches on tantalum clips as compared to matches on bony structures differ substantially. Therefore clip matches can result in smaller CTV to PTV margins than bone matches. Visibility of the clips on EPIs is sufficient, so they can be an alternative to gold markers.« less

  6. Planning the Breast Boost: Comparison of Three Techniques and Evolution of Tumor Bed During Treatment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hepel, Jaroslaw T.; Department of Radiation Oncology, Brown University, Rhode Island Hospital, Providence, RI; Evans, Suzanne B.

    2009-06-01

    Purpose: To evaluate the accuracy of two clinical techniques for electron boost planning compared with computed tomography (CT)-based planning. Additionally, we evaluated the tumor bed characteristics at whole breast planning and boost planning. Methods and Materials: A total of 30 women underwent tumor bed boost planning within 2 weeks of completing whole breast radiotherapy using three planning techniques: scar-based planning, palpation/clinical-based planning, and CT-based planning. The plans were analyzed for dosimetric coverage of the CT-delineated tumor bed. The cavity visualization score was used to define the CT-delineated tumor bed as well or poorly defined. Results: Scar-based planning resulted in inferiormore » tumor bed coverage compared with CT-based planning, with the minimal dose received by 90% of the target volume >90% in 53% and a geographic miss in 53%. The results of palpation/clinical-based planning were significantly better: 87% and 10% for the minimal dose received by 90% of the target volume >90% and geographic miss, respectively. Of the 30 tumor beds, 16 were poorly defined by the cavity visualization score. Of these 16, 8 were well demarcated by the surgical clips. The evaluation of the 22 well-defined tumor beds revealed similar results. A comparison of the tumor bed volume from the initial planning CT scan to the boost planning CT scan revealed a decrease in size in 77% of cases. The mean decrease in volume was 52%. Conclusion: The results of our study have shown that CT-based planning allows for optimal tumor bed coverage compared with clinical and scar-based approaches. However, in the setting of a poorly visualized cavity on CT without surgical clips, palpation/clinical-based planning can help delineate the appropriate target volumes and is superior to scar-based planning. CT simulation at boost planning could allow for a reduction in the boost volumes.« less

  7. A comparative study of female sterilization via modified Uchida and silver clip techniques in rural China.

    PubMed

    Qiu, Hongyan; Li, Li; Wu, Shangchun; Liang, Hong; Yuan, Wei; He, Yingqin

    2011-03-01

    To compare the specific effects of 2 female sterilization methods: the modified Uchida technique and the application of silver clips. A total of 2198 women living in rural areas who were still of reproductive age but opting for sterilization were enrolled. The participants were randomly divided into 2 groups, and underwent sterilization by either modified Uchida technique or silver clips. Information on acceptability, operation conditions, effectiveness, adverse effects, and complaints was collected 3, 6, and 12 months after the procedure. No significant difference in effectiveness, adverse effects or chief complaints between the 2 procedures was found. Differences in operative outcome, bleeding volume during the procedure, and operation time were found. A shorter operation time and less bleeding for the silver clip method indicated that female sterilization by this technique was as safe as that by modified Uchida technique. Copyright © 2010 International Federation of Gynecology and Obstetrics. Published by Elsevier Ireland Ltd. All rights reserved.

  8. The utility of dual-energy CT for metal artifact reduction from intracranial clipping and coiling.

    PubMed

    Mera Fernández, D; Santos Armentia, E; Bustos Fiore, A; Villanueva Campos, A M; Utrera Pérez, E; Souto Bayarri, M

    2018-04-23

    To assess the ability of dual-energy CT (DECT) to reduce metal-related artifacts in patients with clips and coils in head CT angiography, and to analyze the differences in this reduction between both type of devices. Thirteen patients (6 clips, 7 coils) were selected and retrospectively analized. Virtual monoenergetic images (MEI) with photon energies from 40 to 150 keV were obtained. Noise was measured at the area of maximum artifact. Subjective evaluation of streak artifact was performed by two radiologists independently. Differences between noise values in all groups were tested by using the ANOVA test. Mann-Whitney U test was used to compare the differences between clips and coils. Coheńs κ statistic was used to determine interobserver agreement. The lowest noise value was observed at high energy levels (p<0,05). Noise was higher in the coil group than in the clip group (p<0.001). Interobserver agreement was good (κ=0.72). TCED with MEI helps to minimize the artifact from clips ands coils in patients who undergo head CT angiography. The reduction of the artifact is greater in patients with surgical clipping than in patients with endovascular coiling. Copyright © 2018 SERAM. Publicado por Elsevier España, S.L.U. All rights reserved.

  9. Reversible surgical model of biliary inflammation and obstructive jaundice in mice.

    PubMed

    Kirkland, Jacob G; Godfrey, Cody B; Garrett, Ryan; Kakar, Sanjay; Yeh, Benjamin M; Corvera, Carlos U

    2010-12-01

    Common bile duct (CBD) ligation is used in animal models to induce biliary inflammation, fibrosis, and cholestatic liver injury, but results in a high early postoperative mortality rate, probably from traumatic pancreatitis. We modified the CBD ligation model in mice by placing a small metal clip across the lower end of the CBD. To reverse biliary obstruction, a suture was incorporated within the clip during its placement. The suture and clip were removed on postoperative d 5 or 10 for biliary decompression. After 5 d of biliary obstruction, the gallbladder showed an 8-fold increase in wall thickness and a 17-fold increase in tissue myeloperoxidase activity. Markedly elevated serum levels of alkaline phosphatase and bilirubin indicated injury to the biliary epithelium and hepatocytes. Early postoperative (d 0-2) survival was 100% and later (d 3-5) survival was 85% (n=54 mice). We successfully reversed biliary obstruction in 20 mice (37%). Overall survival after reversal was 70%. In surviving mice, biliary decompression was complete, inflammation was reduced, and jaundice resolved. Histologic features confirmed reduced epithelial damage, edema, and neutrophil infiltration. Our technique minimized postoperative death, maintained an effective inflammatory response, and was easily reversible without requiring repeat laparotomy. This reversible model can be used to further define molecular mechanisms of biliary inflammation, fibrosis, and liver injury in genetically altered mice. Copyright © 2010. Published by Elsevier Inc.

  10. Dynamic article: surgical anatomical planes for complete mesocolic excision and applied vascular anatomy of the right colon.

    PubMed

    Açar, Halil İbrahim; Cömert, Ayhan; Avşar, Abdullah; Çelik, Safa; Kuzu, Mehmet Ayhan

    2014-10-01

    Lower local recurrence rates and better overall survival are associated with complete mesocolic excision with central vascular ligation for treatment of colon cancer. To accomplish this, surgeons need to pay special attention to the surgical anatomical planes and vascular anatomy of the colon. However, surgical education in this area has been neglected. The aim of this study is to define the correct surgical anatomical planes for complete mesocolic excision with central vascular ligation and to demonstrate the correct dissection technique for protecting anatomical structures. Macroscopic and microscopic surgical dissections were performed on 12 cadavers in the anatomy laboratory and on autopsy specimens. The dissections were recorded as video clips. Dissections were performed in accordance with the complete mesocolic excision technique on 10 male and 2 female cadavers. Vascular structures, autonomic nerves, and related fascias were shown. Within each step of the surgical procedure, important anatomical structures were displayed on still images captured from videos by animations. Three crucial steps for complete mesocolic excision with central vascular ligation are demonstrated on the cadavers: 1) full mobilization of the superior mesenteric root following the embryological planes between the visceral and the parietal fascias; 2) mobilization of the mesocolon from the duodenum and the pancreas and identification of vascular structures, especially the veins around the pancreas; and 3) central vascular ligation of the colonic vessels at their origin, taking into account the vascular variations within the mesocolonic vessels and the autonomic nerves around the superior mesenteric artery. The limitation of this study was the number of the cadavers used. Successful complete mesocolic excision with central vascular ligation depends on an accurate knowledge of the surgical anatomical planes and the vascular anatomy of the colon.

  11. [Ligation of the retrobulbar vascular-nervous bunch during performance of evisceration and enucleation using titanic clips in ophthalmic surgery].

    PubMed

    Rykov, S A; Torchinskaia, N V; Bakbardina, I I; Simchuk, I V

    2011-10-01

    The efficacy of hemostasis achievement during conduction of a retrobulbar vascular-nervous bunch ligation (RVNBL), using titanic clips while evisceroenucleation performance, was studied up. A comparative analysis of clinical and functional results of surgical treatment of 36 patients, suffering terminal dolorous glaucoma and disaster of a sympathetic ophthalmia complication after an eye penetrating wounding occurrence. In 16 patients (the first group) a standard method of a hemostasis achievement was used while doing evisceroenucleation - a deep orbital tamponade for 5 minutes. In 20 patients (the second group) a procedure of RVNBL was conducted, using titanic clips before the bunch transsection doing. There was established, that while doing a RVNPL using titanic clips, a hemorrhage never occurs, a retrobulbar hematoma do not formated, the soft tissues reaction in the early postoperative period is less pronounced, and the patients postoperative rehabilitation period shortens.

  12. Anterior petroclinoid fold fenestration: an adjunct to clipping of postero-laterally projecting posterior communicating aneurysms.

    PubMed

    Nossek, Erez; Setton, Avi; Dehdashti, Amir R; Chalif, David J

    2014-10-01

    Proximally located posterior communicating artery (PCoA) aneurysms, projecting postero-laterally in proximity to the tentorium, may pose a technical challenge for microsurgical clipping due to obscuration of the proximal aneurysmal neck by the anterior petroclinoid fold. We describe an efficacious technique utilizing fenestration of the anterior petroclinoid fold to facilitate visualization and clipping of PCoA aneurysms abutting this aspect of the tentorium. Of 86 cases of PCoA aneurysms treated between 2003 and 2013, the technique was used in nine (10.5 %) patients to allow for adequate clipping. A 3 mm fenestration in the anterior petroclinoid ligament is created adjacent and lateral to the anterior clinoid process. This fenestration is then widened into a small wedge corridor by bipolar coagulation. In all cases, the proximal aneurysm neck was visualized after the wedge fenestration. Additionally, an adequate corridor for placement of the proximal clip blade was uniformly established. All cases were adequately clipped, with complete occlusion of the aneurysm neck and fundus with preservation of the PCoA. There were two intraoperative ruptures not related to creation of the wedge fenestration. One patient experienced post-operative partial third nerve palsy, which resolved during follow-up. We describe a technique of fenestration of the anterior petroclinoid fold to establish a critical and safe corridor for both visualization and clipping of PCoA aneurysms.

  13. Minimally invasive thoracoscopic closure versus thoracotomy in children with patent ductus arteriosus.

    PubMed

    Stankowski, Tomasz; Aboul-Hassan, Sleiman Sebastian; Marczak, Jakub; Szymanska, Anna; Augustyn, Cyprian; Cichon, Romuald

    2017-02-01

    Patent ductus arteriosus (PDA) is one of the most common congenital heart defects. Once diagnosed, an immediate pharmacologic or invasive treatment should be performed. The purpose of this work was to evaluate the safety and efficacy of surgical PDA ligation in children using video-assisted thoracoscopic surgery (VATS) in comparison with a conventional muscle-sparing posterolateral thoracotomy technique (MSPLT). In this single-center, retrospective study 173 children qualified for surgical PDA closure were enrolled. Patients were divided according to their weight and type of surgery performed. The groups consisted of patients operated through thoracotomy (54%) or VATS (46%). Operative characteristics, cosmetic effect, postoperative complications and long-term survival were evaluated. Regardless of weight, fewer complications were noted in children after thoracoscopic clipping. Fifteen VATS patients required intraoperative conversion to thoracotomy; however, adverse sequelae were not observed. Aesthetics seemed to be the major complaint after conventional surgery. We did not observe any statistically significant differences in the long-term survival between both groups. Both techniques were shown to be safe and effective. Unsuccessfully performed thoracoscopic surgeries were safely converted to conventional thoracotomy. VATS, being a less invasive approach, leads to a better aesthetic effect and lower surgical complication rate. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. Optic neuropathy after anterior communicating artery aneurysm clipping: 3 cases and techniques to address a correctable pitfall.

    PubMed

    Linzey, Joseph R; Chen, Kevin S; Savastano, Luis; Thompson, B Gregory; Pandey, Aditya S

    2018-06-01

    Brain shifts following microsurgical clip ligation of anterior communicating artery (ACoA) aneurysms can lead to mechanical compression of the optic nerve by the clip. Recognition of this condition and early repositioning of clips can lead to reversal of vision loss. The authors identified 3 patients with an afferent pupillary defect following microsurgical clipping of ACoA aneurysms. Different treatment options were used for each patient. All patients underwent reexploration, and the aneurysm clips were repositioned to prevent clip-related compression of the optic nerve. Near-complete restoration of vision was achieved at the last clinic follow-up visit in all 3 patients. Clip ligation of ACoA aneurysms has the potential to cause clip-related compression of the optic nerve. Postoperative visual examination is of utmost importance, and if any changes are discovered, reexploration should be considered as repositioning of the clips may lead to resolution of visual deterioration.

  15. A combination of selected mapping and clipping to increase energy efficiency of OFDM systems

    PubMed Central

    Lee, Byung Moo; Rim, You Seung

    2017-01-01

    We propose an energy efficient combination design for OFDM systems based on selected mapping (SLM) and clipping peak-to-average power ratio (PAPR) reduction techniques, and show the related energy efficiency (EE) performance analysis. The combination of two different PAPR reduction techniques can provide a significant benefit in increasing EE, because it can take advantages of both techniques. For the combination, we choose the clipping and SLM techniques, since the former technique is quite simple and effective, and the latter technique does not cause any signal distortion. We provide the structure and the systematic operating method, and show the various analyzes to derive the EE gain based on the combined technique. Our analysis show that the combined technique increases the EE by 69% compared to no PAPR reduction, and by 19.34% compared to only using SLM technique. PMID:29023591

  16. Development of three-dimensional hollow elastic model for cerebral aneurysm clipping simulation enabling rapid and low cost prototyping.

    PubMed

    Mashiko, Toshihiro; Otani, Keisuke; Kawano, Ryutaro; Konno, Takehiko; Kaneko, Naoki; Ito, Yumiko; Watanabe, Eiju

    2015-03-01

    We developed a method for fabricating a three-dimensional hollow and elastic aneurysm model useful for surgical simulation and surgical training. In this article, we explain the hollow elastic model prototyping method and report on the effects of applying it to presurgical simulation and surgical training. A three-dimensional printer using acrylonitrile-butadiene-styrene as a modeling material was used to produce a vessel model. The prototype was then coated with liquid silicone. After the silicone had hardened, the acrylonitrile-butadiene-styrene was melted with xylene and removed, leaving an outer layer as a hollow elastic model. Simulations using the hollow elastic model were performed in 12 patients. In all patients, the clipping proceeded as scheduled. The surgeon's postoperative assessment was favorable in all cases. This method enables easy fabrication at low cost. Simulation using the hollow elastic model is thought to be useful for understanding of three-dimensional aneurysm structure. Copyright © 2015 Elsevier Inc. All rights reserved.

  17. Surgical Management of Ruptured Isolated Aneurysm of Artery of Adamkiewicz: Interesting Report and Overview of Literature.

    PubMed

    Aljuboori, Zaid; Sharma, Mayur; Simpson, Jessica; Altstadt, Thomas

    2018-03-01

    Spinal subarachnoid hemorrhage due to rupture of an isolated spinal aneurysm is extremely rare. Patients usually present with symptoms and signs resulting from spinal cord compression. No standard guidelines are available for the treatment of this condition. In this report we present the case of a 78-year-old Caucasian male who presented with sudden-onset back pain and bilateral lower extremity weakness. Spinal angiogram revealed an isolated aneurysm of the artery of Adamkiewicz. The aneurysm was successfully managed by surgical clipping, and the patient recovered well with rehabilitation. At 46 months' follow-up, the patient was able to ambulate and perform activities of daily living independently. Our case is the first description of surgical clipping of a ruptured isolated spinal aneurysm of the artery of Adamkiewicz with a long-term successful outcome and shows that it is a safe and feasible option in carefully selected patients. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. Gaze entropy reflects surgical task load.

    PubMed

    Di Stasi, Leandro L; Diaz-Piedra, Carolina; Rieiro, Héctor; Sánchez Carrión, José M; Martin Berrido, Mercedes; Olivares, Gonzalo; Catena, Andrés

    2016-11-01

    Task (over-)load imposed on surgeons is a main contributing factor to surgical errors. Recent research has shown that gaze metrics represent a valid and objective index to asses operator task load in non-surgical scenarios. Thus, gaze metrics have the potential to improve workplace safety by providing accurate measurements of task load variations. However, the direct relationship between gaze metrics and surgical task load has not been investigated yet. We studied the effects of surgical task complexity on the gaze metrics of surgical trainees. We recorded the eye movements of 18 surgical residents, using a mobile eye tracker system, during the performance of three high-fidelity virtual simulations of laparoscopic exercises of increasing complexity level: Clip Applying exercise, Cutting Big exercise, and Translocation of Objects exercise. We also measured performance accuracy and subjective rating of complexity. Gaze entropy and velocity linearly increased with increased task complexity: Visual exploration pattern became less stereotyped (i.e., more random) and faster during the more complex exercises. Residents performed better the Clip Applying exercise and the Cutting Big exercise than the Translocation of Objects exercise and their perceived task complexity differed accordingly. Our data show that gaze metrics are a valid and reliable surgical task load index. These findings have potential impacts to improve patient safety by providing accurate measurements of surgeon task (over-)load and might provide future indices to assess residents' learning curves, independently of expensive virtual simulators or time-consuming expert evaluation.

  19. The outcome of a surgical protocol based on ischemia overprotection in large and giant aneurysms of the anterior cerebral circulation.

    PubMed

    Imai, Hideaki; Watanabe, Katsushige; Miyagishima, Takaaki; Yoshimoto, Yuhei; Kin, Taichi; Nakatomi, Hirofumi; Saito, Nobuhito

    2016-07-01

    Aiming to define the optimal treatment of large and giant aneurysms (LGAs) in the anterior circulation, we present our surgical protocol and patient outcome. A series of 42 patients with intracavernous LGAs (n = 16), paraclinoid (C2) LGAs (n = 17), and peripheral (middle cerebral artery-MCA or anterior cerebral artery-ACA) LGAs (n = 9) were treated after bypass under motor evoked potential (MEP) monitoring. Preoperatively, three categories of ischemic tolerance during internal carotid artery (ICA) occlusion were defined on conventional angiography: optimal, suboptimal, and insufficient collaterals. Accordingly, three types of bypass: low flow (LFB), middle flow (MFB) and high flow (HFB) were applied for the cases with optimal, suboptimal, and insufficient collaterals, respectively. Outcome was evaluated by the Glasgow Outcome Scale (GOS). All patients had excellent GOS score except one, who suffered a major ischemic stroke immediately after surgery for a paraclinoid lesion. Forty-one patients were followed up for 87.1 ± 40.1 months (range 13-144 months). Intracavernous LGAs were all treated by proximal occlusion with bypass surgery. Of paraclinoid LGA patients, 15 patients had direct clipping under suction decompression and other 2 patients with recurrent aneurysms had ICA (C2) proximal clipping with HFB. MEP monitoring guided for temporary clipping time and clip repositioning, observing significant MEP changes for up to 6 min duration. Of 9 peripheral LGAs patients 7 MCA LGAs had reconstructive clipping (n = 4) or trapping (n = 3) with bypass including LFB in 3 cases, MFB in 1 and HFB in 1. Two ACA LGAs had clipping (n = 1) or trapping (n = 1) with A3-A3 bypass. The applied protocol provided excellent results in intracavernous, paraclinoid, and peripheral thrombosed LGAs of the anterior circulation.

  20. Implant-specific follow-up imaging of treated intracranial aneurysms: TOF-MRA vs. metal artifact reduced intravenous flat panel computed tomography angiography (FPCTA).

    PubMed

    Hänsel, N H; Schubert, G A; Scholz, B; Nikoubashman, O; Othman, A E; Wiesmann, M; Pjontek, R; Brockmann, M A

    2018-02-01

    To compare the diagnostic quality of time-of-flight magnetic resonance angiography (TOF-MRA) and metal-artefact-reduction (MAR) flat-panel-detector computed tomography angiography (FPCTA) and to determine the imaging technique best suited for evaluation endovascular and surgically treated aneurysms. The image quality of TOF-MRA and MAR-FPCTA of 44 intracranial implants (coiling: n=20; clipping: n=15; coiling + stenting: n=9) in a patient cohort of 25 was evaluated by two independent readers. Images obtained using MAR-FPCTA (20 second scan time, 496 projections, intravenous contrast medium administration; Artis Zee, Siemens Healthcare, Forchheim) were compared with TOF-MRA-images (1.5 or 3 T). Nominal data were analysed using McNemar's chi-square test and ordinal variables using the Wilcoxon rank test. Compared to TOF-MRA, MAR-FPCTA was significantly better suited to detect aneurysm remnants and to evaluate parent vessels after clipping (p<0.01). For coil packages >160 mm 3 , TOF-MRA provided significantly better assessment than MAR-FPCTA (p<0.01). For small coil packages (<160 mm 3 ), no significant difference between TOF-MRA and MAR-FPCTA (p=0.232) was observed. For different clip sizes (cut-off 492 mm 3 ) likewise no significant differences were found. The interobserver comparison showed high interrater agreement. MAR-FPCTA is significantly better suited for follow-up examinations of clipped aneurysms, whereas for larger coil packages TOF-MRA is preferable. Smaller coil packages can be analysed using MAR-FPCTA or TOF-MRA. Copyright © 2017 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  1. Microsurgical subtemporal approach to aneurysms on the P(2) segment of the posterior cerebral artery.

    PubMed

    Zhitao, Jing; Yibao, Wang; Anhua, Wu; Shaowu, Ou; Yunchao, Ban; Renyi, Zhou; Yunjie, Wang

    2010-01-01

    Aneurysms arising from the P(2) segment of the posterior cerebral artery (PCA) are rare, accounting for less than 1% of all intracranial aneurysms. To date, few studies concerning the management of P(2) segment aneurysms have been reported. To review the microsurgical techniques and clinical outcomes of microsurgical treatment by different approaches in patients with aneurysms on the P(2) segment of the PCA. Forty-two patients with P2 segment aneurysms had microsurgical treatment by subtemporal approach. All the patients had drainage of cerebrospinal fluid for decompression, and indocyanine green (ICG) angiography was used in 20 patients to assess the effect of clipping. Of the 42 patients, 16 were operated by combined pterional-subtemporal approach. In 40 patients aneurysms were successfully treated by clipping the P(2) aneurysmal neck while preserving the parent artery. Two patients with giant aneurysms were treated using surgical trapping. Postoperatively, 41 patients had a good recovery. One patient after aneurysm trapping had ischemic infarction in the PCA tertiary and presented with hemiparesis and homonymous hemianopia. However, this patient recovered after three weeks of treatment. Subtemporal approach is the most appropriate approach to clip the aneurysms of the P(2) segment. It allows the neurosurgeon to operate on the aneurysms while preserving the patency of the parent artery. Gaint P(2) segment aneurysms can safely be treated by rapping of the aneurysm by combined subtemporal or pterional-subtemporal approach in experienced hands. ICG angiography will be an important tool in monitoring for the presence of residual aneurysm or perforating artery occlusion during aneurysm clipping. Preoperative lumbar drainage of cerebrospinal fluid may help to avoid temporal lobe damage.

  2. Neuropsychological function after endovascular and neurosurgical treatment of subarachnoid hemorrhage: a systematic review and meta-analysis.

    PubMed

    Egeto, Peter; Loch Macdonald, R; Ornstein, Tisha J; Schweizer, Tom A

    2018-03-01

    OBJECTIVE Subarachnoid hemorrhage (SAH) is treated with either surgical clipping or endovascular coiling, though the latter is the preferred treatment method given its more favorable functional outcomes. However, neuropsychological functioning after treatment is rarely taken into account. In this meta-analysis, the authors synthesized relevant data from the literature and compared neuropsychological functioning in patients after coiling and clipping of SAH. They hypothesized that the coiled patients would outperform the clipped patients; that group differences would be greater with higher posterior circulation rupture rates, in older patients, and in more recent publications; that group differences would be smaller with greater rates of middle cerebral artery (MCA) rupture; and that anterior communicating artery (ACoA) rupture rates would not influence effect sizes. METHODS The MEDLINE, Embase, and PsycINFO databases were searched for clinical studies that compared neuropsychological functioning after either endovascular coiling or surgical clipping for SAH. Hedge's g and 95% confidence intervals were calculated using random effects models. Patients who had undergone coiling or clipping were compared on test performance in 8 neuropsychological domains: executive functions, language, attention/processing speed, verbal memory, visual memory, spatial memory, visuospatial functions, and intelligence. Patients were also compared with healthy controls, and meta-regressions were used to explore the relation between effect sizes and publication year, delay between treatment and neuropsychological testing, mean patient age, and rates of posterior circulation, ACoA, and MCA ruptures. RESULTS Thirteen studies with 396 clipped cases, 314 coiled cases, and 169 healthy controls were included in the study. The coil-treated patients outperformed the clip-treated patients on executive function (g = 0.17, 95% CI 0.08-0.25) and language tests (g = 0.23, 95% CI 0.07-0.39), and all patients were impaired relative to healthy controls (g ranged from -0.93 to -0.29). Coiled patients outperformed clipped patients to a greater degree in more recent publications, over longer posttreatment testing delays, and among older patients. Higher rates of posterior circulation and MCA aneurysms were associated with smaller group differences, while ACoA rupture rates did not influence effect sizes. CONCLUSIONS Coiling of SAH may promote superior neuropsychological functioning under certain circumstances and could have applications for the specialized care of SAH patients.

  3. Catheter Entrapment During Posterior Mitral Leaflet Pushing Maneuver for MitraClip Implantation.

    PubMed

    Castrodeza, Javier; Amat-Santos, Ignacio J; Tobar, Javier; Varela-Falcón, Luis H

    2016-06-01

    MitraClip (Abbott Vascular) therapy has been reported to be an effective procedure for mitral regurgitation, especially in high-risk patients. Recently, the novel pushing maneuver technique has been described for approaching restricted and short posterior leaflets with a pigtail catheter in order to facilitate grasping of the clip. However, complications or unexpected situations may occur. We report the case of an 84-year-old patient who underwent MitraClip implantation wherein the pushing maneuver was complicated by the clip accidentally gripping the pigtail catheter along with the two leaflets.

  4. Integrating an object system into CLIPS: Language design and implementation issues

    NASA Technical Reports Server (NTRS)

    Auburn, Mark

    1990-01-01

    This paper describes the reasons why an object system with integrated pattern-matching and object-oriented programming facilities is desirable for CLIPS and how it is possible to integrate such a system into CLIPS while maintaining the run-time performance and the low memory usage for which CLIPS is known. The requirements for an object system in CLIPS that includes object-oriented programming and integrated pattern-matching are discussed and various techniques for optimizing the object system and its integration with the pattern-matcher are presented.

  5. The importance of prostate bed tilt during postprostatectomy intensity-modulated radiotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bell, Linda J., E-mail: Linda.Bell1@health.nsw.gov.au; Faculty of Health Sciences, University of Sydney, Lidcombe, New South Wales; Cox, Jennifer

    2014-10-01

    Variations in rectal and bladder filling can create a tilt of the prostate bed, which generates the potential for a geographic miss during postprostatectomy radiotherapy. The aim of this study is to assess the effect that bladder and rectum filling has on planning target volume angle, to determine a method to assess prostate bed tilt leading to potential geographic miss, and to discuss possible implementation issues. The cone-beam computed tomography images (n = 377) of 40 patients who received postprostatectomy radiotherapy with intensity-modulated radiotherapy were reviewed. The amount of tilt in the prostate bed was defined as the angle changemore » between 2 surgical clips, one in the upper prostate bed and another in the lower. A potential geographic miss was defined as movement of any clip of more than 1 cm in any direction or 0.5 cm posteriorly when aligned to bone anatomy. Variations in bladder and rectum size were correlated with the degree of prostate bed tilt, and the rate of potential geographic miss was determined. A possible clinical use of prostate bed tilt was then assessed for different imaging techniques. A tilt of more than 10° was seen in 20.2% of images, which resulted in a 57.9% geographic miss rate of the superior clip. When tilt remained within 10°, there was only a 9% rate of geographic miss. Potential geographic miss of the inferior surgical clip was rare, occurring in only 1.9% of all images reviewed. The most common occurrence when the prostate bed tilt increased by more than 10° was a smaller bladder and larger rectum (6.4% of all images). The most common occurrence when the prostate bed tilt decreased by more than 10° was a larger bladder and smaller rectum (1.3% of all images). Significant prostate bed tilt (>± 10°) occurred in more than 20% of images, creating a 58% rate of geographic miss. Greatest prostate bed tilt occurred when the bladder size increased or reduced by more than 2 cm or the superior rectum size increased by more than 1.5 cm or reduced by more than 1 cm from the planned size. Using prostate bed tilt could be an effective measurement for assessing potential geographic miss on orthogonal images if volumetric imaging is unavailable.« less

  6. Using CLIPS as the cornerstone of a graduate expert systems course

    NASA Technical Reports Server (NTRS)

    Yue, Kwok-Bun

    1991-01-01

    The effective use of the C Language Integrated Production System (CLIPS) as a cornerstone in a graduate expert systems course is described. The course include 8 or 9 hours of in-depth lecturing in CLIPS, as well as a broad coverage of major topics and techniques in expert systems. As part of the requirements of the course, students solved two small yet non-trival problems in CLIPS before going on to develop a toy expert system in CLIPS in an incremental manner as the term project. Furthermore, students were required to evaluate CLIPS programs written by their classmates. An anonymous questionnaire at the end of the semester revealed that the students responded very favorably to the course, especially their experience with CLIPS.

  7. Advanced real-time multi-display educational system (ARMES): An innovative real-time audiovisual mentoring tool for complex robotic surgery.

    PubMed

    Lee, Joong Ho; Tanaka, Eiji; Woo, Yanghee; Ali, Güner; Son, Taeil; Kim, Hyoung-Il; Hyung, Woo Jin

    2017-12-01

    The recent scientific and technologic advances have profoundly affected the training of surgeons worldwide. We describe a novel intraoperative real-time training module, the Advanced Robotic Multi-display Educational System (ARMES). We created a real-time training module, which can provide a standardized step by step guidance to robotic distal subtotal gastrectomy with D2 lymphadenectomy procedures, ARMES. The short video clips of 20 key steps in the standardized procedure for robotic gastrectomy were created and integrated with TilePro™ software to delivery on da Vinci Surgical Systems (Intuitive Surgical, Sunnyvale, CA). We successfully performed the robotic distal subtotal gastrectomy with D2 lymphadenectomy for patient with gastric cancer employing this new teaching method without any transfer errors or system failures. Using this technique, the total operative time was 197 min and blood loss was 50 mL and there were no intra- or post-operative complications. Our innovative real-time mentoring module, ARMES, enables standardized, systematic guidance during surgical procedures. © 2017 Wiley Periodicals, Inc.

  8. Surgical management of giant posterior communicating artery aneurysms.

    PubMed

    Velat, Gregory J; Zabramski, Joseph M; Nakaji, Peter; Spetzler, Robert F

    2012-09-01

    Giant posterior communicating artery (PCoA) aneurysms (> 25 mm) are rare lesions associated with a poor prognosis and high rates of morbidity and mortality. To review the clinical results of giant PCoA aneurysms surgically treated at our institution, focusing on operative nuances. All cases of giant PCoA aneurysms treated surgically at our institution were identified from a prospectively maintained patient database. Patient demographic factors, medical comorbidities, rupture status, neurological presentation, clinical outcomes, and surgical records were critically reviewed. From 1989 to 2010, 11 patients (10 women) underwent surgical clipping of giant PCoA aneurysms. Presenting signs and symptoms included cranial nerve palsies, diminished mental status, headache, visual changes, and seizures. Five aneurysms were ruptured on admission. All aneurysms were clipped primarily except 1, which was treated by parent artery sacrifice and extracranial-to-intracranial bypass after intraoperative aneurysm rupture. Perioperative morbidity and mortality rates were 36% (4 of 11) and 18.3% (2 of 11), respectively. Excellent or good clinical outcomes, defined as modified Rankin Scale scores ≤ 2, were achieved in 86% (5 of 6) of patients available for long-term clinical follow-up (mean, 12.5 ± 13.6 months). Giant PCoA aneurysms are rare vascular lesions that may present with a variety of neurological signs and symptoms. These lesions can be successfully managed surgically with satisfactory morbidity and mortality rates. To the best of our knowledge, this is the largest surgical series of giant PCoA aneurysms published to date.

  9. Retrograde Suction Decompression with an Inahara Carotid Shunt for Clipping a Large Distal Internal Carotid Artery Aneurysm.

    PubMed

    Park, Yong Sook; Nam, Taek Kyun

    2017-03-01

    We describe a technique to clip a large internal carotid artery (ICA) aneurysm via a retrograde suction decompression (RSD). A large aneurysm in the right distal ICA involving the bifurcation region measuring 1.2×1.1×0.7 cm with posterior projection was managed with assisted RSD technique. The anterior choroidal artery emerged from the side wall of the aneurysm. An Inahara shunt was inserted into the ICA with neck dissection, and RSD was applied after completely clipping the aneurysm. RSD with an Inahara carotid shunt is useful for complete visualization of the aneurysm, including its surrounding structures, and for proximal control of the parent vessels, subsequently achieving satisfactory clip placement.

  10. Assessment of Caudal Fin Clips as a Non-lethal Technique for Predicting Muscle Tissue Mercury Concentrations in Largeouth Bass

    EPA Science Inventory

    The statistical relationship between total mercury (Hg) concentration in clips from the caudal fin and muscle tissue of largemouth bass (Micropterus salmoides) from 26 freshwater sites in Rhode Island, USA was developed and evaluated to determine the utility of fin clip analysis ...

  11. Intracorporeal hybrid single port vs conventional laparoscopic appendectomy in children.

    PubMed

    Karam, Paul Anthony; Hiuser, Amy; Magnuson, David; Seifarth, Federico Gian Filippo

    2016-12-20

    Transumbilical laparoscopic assisted appendectomy combines laparoscopic single port dissection with open appendectomy after exteriorization of the appendix through the port site. Compared to the conventional three-port approach, this technique provides an alternative with excellent cosmetic outcome. We developed a safe and effective technique to perform an intracorporeal single port appendectomy, using the same laparoscope employed in the extracorporeal procedure. Retrospective review of 71 consecutively performed intracorporeal single port appendectomies and 30 conventional three-port appendectomies in children 6 to 17 years of age. A straight 10-mm Storz telescope with inbuilt 6 mm working channel is used to dissect the appendix, combined with one port-less 2.3 mm percutaneous grasper. Polymer WECK® hem-o-lock® clips are applied to seal the base of the appendix and the appendiceal vessels. No intraoperative complications were reported with the hybrid intracorporeal single port appendectomy or three-port appendectomy. There were two post-operative complications in the group treated with the single port hybrid technique: one intra-abdominal abscess and one surgical site infection. Groups did not differ in age, weight, and types of appendicitis. Operative times were shorter for the hybrid technique (70 vs 79 minutes) but did not differ significantly (P=0.19). This modified technique to a previously described single port extracorporeal appendectomy is easy to master and implement. It provides exposure similar to a three-port laparoscopic appendectomy, while maintaining virtually scarless results and potentially reduces the risk for surgical site infections compared to the extracorporeal technique.

  12. Delphi consensus on bile duct injuries during laparoscopic cholecystectomy: an evolutionary cul-de-sac or the birth pangs of a new technical framework?

    PubMed

    Iwashita, Yukio; Hibi, Taizo; Ohyama, Tetsuji; Umezawa, Akiko; Takada, Tadahiro; Strasberg, Steven M; Asbun, Horacio J; Pitt, Henry A; Han, Ho-Seong; Hwang, Tsann-Long; Suzuki, Kenji; Yoon, Yoo-Seok; Choi, In-Seok; Yoon, Dong-Sup; Huang, Wayne Shih-Wei; Yoshida, Masahiro; Wakabayashi, Go; Miura, Fumihiko; Okamoto, Kohji; Endo, Itaru; de Santibañes, Eduardo; Giménez, Mariano Eduardo; Windsor, John A; Garden, O James; Gouma, Dirk J; Cherqui, Daniel; Belli, Giulio; Dervenis, Christos; Deziel, Daniel J; Jonas, Eduard; Jagannath, Palepu; Supe, Avinash Nivritti; Singh, Harjit; Liau, Kui-Hin; Chen, Xiao-Ping; Chan, Angus C W; Lau, Wan Yee; Fan, Sheung Tat; Chen, Miin-Fu; Kim, Myung-Hwan; Honda, Goro; Sugioka, Atsushi; Asai, Koji; Wada, Keita; Mori, Yasuhisa; Higuchi, Ryota; Misawa, Takeyuki; Watanabe, Manabu; Matsumura, Naoki; Rikiyama, Toshiki; Sata, Naohiro; Kano, Nobuyasu; Tokumura, Hiromi; Kimura, Taizo; Kitano, Seigo; Inomata, Masafumi; Hirata, Koichi; Sumiyama, Yoshinobu; Inui, Kazuo; Yamamoto, Masakazu

    2017-11-01

    Bile duct injury (BDI) during laparoscopic cholecystectomy remains a serious iatrogenic surgical complication. BDI most often occurs as a result of misidentification of the anatomy; however, clinical evidence on its precise mechanism and surgeons' perceptions is scarce. Surgeons from Japan, Korea, Taiwan, and the USA, etc. (n = 614) participated in a questionnaire regarding their BDI experience and near-misses; and perceptions on landmarks, intraoperative findings, and surgical techniques. Respondents voted for a Delphi process and graded each item on a five-point scale. The consensus was built when ≥80% of overall responses were 4 or 5. Response rates for the first- and second-round Delphi were 60.6% and 74.9%, respectively. Misidentification of local anatomy accounted for 76.2% of BDI. Final consensus was reached on: (1) Effective retraction of the gallbladder, (2) Always obtaining critical view of safety, and (3) Avoiding excessive use of electrocautery/clipping as vital procedures; and (4) Calot's triangle area and (5) Critical view of safety as important landmarks. For (6) Impacted gallstone and (7) Severe fibrosis/scarring in Calot's triangle, bail-out procedures may be indicated. A consensus was reached among expert surgeons on relevant landmarks and intraoperative findings and appropriate surgical techniques to avoid BDI. © 2017 Japanese Society of Hepato-Biliary-Pancreatic Surgery.

  13. [Neuroanesthetic management for surgical clipping of a ruptured cerebral aneurysm: clinical practice guidelines].

    PubMed

    Ingelmo Ingelmo, I; Carmona Aurioles, J; Rama-Maceiras, P; Fàbregas Julià, N; Hernández-Palazón, J

    2010-12-01

    Subarachnoid hemorrhage due to spontaneous rupture of a cerebral aneurysm is associated with high rates of morbidity and mortality and requires multidisciplinary treatment. The debate on surgical vs endovascular treatment continues, although short-term clinical outcomes and survival rates are better after endovascular treatment. In Spain, a strong trend toward reduced use of clipping has been noted, and neuroanesthetists are less often called on to provide anesthesia in this setting. Our intervention, however, can be decisive. The neuroscience working group of the Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor has developed guidelines for managing anesthesia in these procedures. Based on a national survey and a systematic review of the literature, the recommendations emphasize the importance of ensuring appropriate intracranial conditions, treating complications, and taking steps to protect against cerebral hemorrhage.

  14. Clinical impact of IMPORT HIGH trial (CRUK/06/003) on breast radiotherapy practices in the United Kingdom

    PubMed Central

    Ciurlionis, Laura; Kirby, Anna M; Locke, Imogen; Venables, Karen; Yarnold, John R; Titley, Jenny; Bliss, Judith; Coles, Charlotte E

    2015-01-01

    Objective: IMPORT HIGH is a multicentre randomized UK trial testing dose-escalated intensity-modulated radiotherapy (IMRT) after tumour excision in females with early breast cancer and higher than average local recurrence risk. A survey was carried out to investigate the impact of this trial on the adoption of advanced breast radiotherapy (RT) techniques in the UK. Methods: A questionnaire was sent to all 26 IMPORT HIGH recruiting RT centres to determine whether the trial has influenced non-trial breast RT techniques in terms of volume delineation, dosimetry, treatment delivery and verification. In order to compare the clinical practice of breast RT between IMPORT HIGH and non–IMPORT HIGH centres, parts of the Royal College of Radiologists (RCR) breast RT audit result were used in this study. Results: 26/26 participating centres completed the questionnaire. After joining the trial, the number of centres routinely using tumour bed clips to guide whole-breast RT rose from 5 (19%) to 21 (81%). 20/26 (77%) centres now contour target volumes and organs at risk (OARs) in some or all patients compared with 14 (54%) before the trial. 14/26 (54%) centres offer inverse-planned IMRT for selected non-trial patients with breast cancer, and 10/14 (71%) have adopted the IMPORT HIGH trial protocol for target volume and OARs dose constraints. Only 2/26 (8%) centres used clip information routinely for breast treatment verification prior to IMPORT HIGH, a minority that has since risen to 7/26 (27%). Data on 1386 patients was included from the RCR audit. This suggested that more cases from IMPORT HIGH centres had surgical clips implanted (83 vs 67%), were treated using CT guided planning with full three-dimensional dose compensation (100 vs 75%), and were treated with photon boost RT (30 vs 8%). Conclusion: The study suggests that participation in the IMPORT HIGH trial has played an important part in providing the guidance and support networks needed for the safe integration of advanced RT techniques, where appropriate, as a standard of care for breast cancer patients treated at participating cancer centres. Advances in knowledge: We investigated the impact of the IMPORT HIGH trial on the adoption of advanced breast RT techniques in the UK and the trial has influenced non-trial breast RT techniques in terms of volume delineation, dosimetry, treatment delivery and verification. PMID:26492402

  15. Clinical impact of IMPORT HIGH trial (CRUK/06/003) on breast radiotherapy practices in the United Kingdom.

    PubMed

    Tsang, Yat; Ciurlionis, Laura; Kirby, Anna M; Locke, Imogen; Venables, Karen; Yarnold, John R; Titley, Jenny; Bliss, Judith; Coles, Charlotte E

    2015-01-01

    IMPORT HIGH is a multicentre randomized UK trial testing dose-escalated intensity-modulated radiotherapy (IMRT) after tumour excision in females with early breast cancer and higher than average local recurrence risk. A survey was carried out to investigate the impact of this trial on the adoption of advanced breast radiotherapy (RT) techniques in the UK. A questionnaire was sent to all 26 IMPORT HIGH recruiting RT centres to determine whether the trial has influenced non-trial breast RT techniques in terms of volume delineation, dosimetry, treatment delivery and verification. In order to compare the clinical practice of breast RT between IMPORT HIGH and non-IMPORT HIGH centres, parts of the Royal College of Radiologists (RCR) breast RT audit result were used in this study. 26/26 participating centres completed the questionnaire. After joining the trial, the number of centres routinely using tumour bed clips to guide whole-breast RT rose from 5 (19%) to 21 (81%). 20/26 (77%) centres now contour target volumes and organs at risk (OARs) in some or all patients compared with 14 (54%) before the trial. 14/26 (54%) centres offer inverse-planned IMRT for selected non-trial patients with breast cancer, and 10/14 (71%) have adopted the IMPORT HIGH trial protocol for target volume and OARs dose constraints. Only 2/26 (8%) centres used clip information routinely for breast treatment verification prior to IMPORT HIGH, a minority that has since risen to 7/26 (27%). Data on 1386 patients was included from the RCR audit. This suggested that more cases from IMPORT HIGH centres had surgical clips implanted (83 vs 67%), were treated using CT guided planning with full three-dimensional dose compensation (100 vs 75%), and were treated with photon boost RT (30 vs 8%). The study suggests that participation in the IMPORT HIGH trial has played an important part in providing the guidance and support networks needed for the safe integration of advanced RT techniques, where appropriate, as a standard of care for breast cancer patients treated at participating cancer centres. We investigated the impact of the IMPORT HIGH trial on the adoption of advanced breast RT techniques in the UK and the trial has influenced non-trial breast RT techniques in terms of volume delineation, dosimetry, treatment delivery and verification.

  16. Spatially controlled coating of continuous liquid Interface production microneedles for transdermal protein delivery.

    PubMed

    Caudill, Cassie L; Perry, Jillian L; Tian, Shaomin; Luft, J Christopher; DeSimone, Joseph M

    2018-06-09

    Microneedle patches, arrays of micron-scale projections that penetrate skin in a minimally invasive manner, are a promising tool for transdermally delivering therapeutic proteins. However, current microneedle fabrication techniques are limited in their ability to fabricate microneedles rapidly and with a high degree of control over microneedle design parameters. We have previously demonstrated the ability to fabricate microneedle patches with a range of compositions and geometries using the novel additive manufacturing technique Continuous Liquid Interface Production (CLIP). Here, we establish a method for dip coating CLIP microneedles with protein cargo in a spatially controlled manner. Microneedle coating mask devices were fabricated with CLIP and utilized to coat polyethylene glycol-based CLIP microneedles with model proteins bovine serum albumin, ovalbumin, and lysozyme. The design of the coating mask device was used to control spatial deposition and loading of coated protein cargo on the microneedles. CLIP microneedles rapidly released coated protein cargo both in solution and upon insertion into porcine skin. The model enzyme lysozyme was shown to retain its activity throughout the CLIP microneedle coating process, and permeation of bovine serum albumin across full thickness porcine skin was observed after application with coated CLIP microneedles. Protein-coated CLIP microneedles were applied to live mice and showed sustained retention of protein cargo in the skin over 72 h. These results demonstrate the utility of a versatile coating platform for preparation of precisely coated microneedles for transdermal therapeutic delivery. Copyright © 2018. Published by Elsevier B.V.

  17. High-flow bypass and wrap-clipping for ruptured blood blister-like aneurysm of the internal carotid artery using intraoperative monitoring of cerebral hemodynamics

    PubMed Central

    Kubo, Yoshitaka; Koji, Takahiro; Yoshida, Kenji; Saito, Hideo; Ogawa, Akira; Ogasawara, Kuniaki

    2015-01-01

    Aneurysms at non-branching sites in the supraclinoid internal carotid artery (ICA) can be classified as “blood blister-like aneurysms” (BBAs), which have blood blister-like configurations and fragile walls. While surgical treatment for the BBA in the acute stage is recommended, the optimal surgical procedure remains controversial. In the study reported here, we describe the case of a 37-year-old woman with a ruptured BBA in the ophthalmic segment of the right ICA who underwent wrap-clipping with external carotid artery–internal carotid artery bypass by intraoperative estimation of the measurement of cortical cerebral blood flow (CoBF) using a thermal diffusion flow probe. Trapping of the ICA in the acute stage of subarachnoid hemorrhage may result in ischemic complications secondary to hemodynamic hypoperfusion or occlusion of the perforating artery, and/or delayed vasospasm, even with concomitant bypass surgery. We believe that it is important to perform scheduled external carotid artery–internal carotid artery bypass before trapping of the ICA in patients with a ruptured BBA in the acute stage of subarachnoid hemorrhage and to perform wrap-clipping rather than trapping. This would provide much more CoBF if a reduction of CoBF occurs after trapping occlusion of the ICA including a ruptured BBA according to intraoperative CoBF monitoring. As far as we are aware, the case reported here is the first report on high-flow bypass and wrap-clipping for a ruptured BBA of the ICA using intraoperative monitoring of cerebral hemodynamics. PMID:26082641

  18. Easy clip to treat anal fistula tracts: a word of caution.

    PubMed

    Gautier, M; Godeberge, P; Ganansia, R; Bozio, G; Godart, B; Bigard, M A; Barthet, M; Siproudhis, L

    2015-05-01

    Closing the internal opening by a clip ovesco has been recently proposed for healing the fistula tract, but, to date, data on benefit are poorly analyzed. The aim was to report a preliminary multicenter experience. Retrospective study was undertaken in six different French centers: surgical procedure, immediate complications, and follow-up have been collected. Nineteen clips were inserted in 17 patients (M/F, 4/13; median age, 42 years [29-54]) who had an anal fistula: 12 (71%) high fistulas (including 4 rectovaginal fistulas), 5 (29%) lower fistulas (with 3 rectovaginal fistulas), and 6 (35%) Crohn's fistulas. Out of 17 patients, 15 had a seton drainage beforehand. The procedure was easy in 8 (47%) patients and the median operative time was 27.5 min (20-36.5). Postoperative period was painful for 11 (65%) patients. A clip migration was noted in 11 patients (65%) after a median follow-up of 10 days (5.5-49.8). Eleven patients (65%) who failed had reoperation including 10 new drainages within the first month (0.5-5). After a mean follow-up of 4 months (2-7),, closing the tract was observed in 2 patients (12%) following the first insertion of the clip and in another one after a second insertion. Treatment of anal fistula by placing a clip on the internal opening is disappointing and deleterious for some patients. A better assessment before dissemination is recommended.

  19. Teaching Surgical Procedures with Movies: Tips for High-quality Video Clips.

    PubMed

    Jacquemart, Mathieu; Bouletreau, Pierre; Breton, Pierre; Mojallal, Ali; Sigaux, Nicolas

    2016-09-01

    Video must now be considered as a precious tool for learning surgery. However, the medium does present production challenges, and currently, quality movies are not always accessible. We developed a series of 7 surgical videos and made them available on a publicly accessible internet website. Our videos have been viewed by thousands of people worldwide. High-quality educational movies must respect strategic and technical points to be reliable.

  20. Segmental liver resection assisted by HIFU: tissue precauterization using a toroidal-shaped HIFU transducer

    NASA Astrophysics Data System (ADS)

    N'Djin, W. A.; Melodelima, D.; Schenone, F.; Rivoire, M.; Chapelon, J. Y.

    2010-03-01

    The development of new cauterization techniques for hepatic resection is critical for improving the safety of the procedure. Previous studies showed the feasibility of using HIFU or radiofrequency precoagulation to limit blood loss during dissection of the organ. Here we report a new therapeutic modality using high intensity focused ultrasound (HIFU) to perform a bloodless hepatic resection that could represent a promising alternative. A comparative study was performed to evaluate the interest of using this complementary tool to improve surgical resection in the liver. This study used a 3 MHz HIFU toroidal-shaped phased array transducer which allows the generation of a single conical lesion of 7 cm3 in 40 seconds. In order to minimize blood loss and dissection time, a barrier of coagulative necrosis was generated with the HIFU device before hepatectomy, by juxtaposing single conical lesions on the line of dissection. Resection assisted by HIFU (RA-HIFU) was compared with classical dissections with clamping (RC) and without clamping (Control). For each technique 14 partial liver resections were performed in seven pigs. The parameters examined were vascular control and times of treatment. Precoagulation allowed the vascular isolation of small vessels and surgical clips were mainly used for the control of vessels>5 mm in diameter. The number of clips used per unit of liver surface dissected in RA-HIFU (0.8±0.3 cm-2) was significantly lower than in the other groups (RC: 1.6±0.4 cm-2, Control: 1.8±0.8 cm-2, p<0.01). In addition, blood loss was lower in RA-HIFU (7.4±6.5 ml.cm-2) than in RC (11.2±4.5 ml.cm-2) and Control (14.0±6.7 ml.cm-2). The time of dissection in RA-HIFU (13±5 min) was shorter than in RC (23±8 minutes) and Control (18±5 minutes). The feasibility and the efficiency of RA-HIFU using a toroidal-shaped HIFU transducer without additional devices were demonstrated. This technique enhances the resection procedure and will be able to be tested in clinic.

  1. Surgical revision after percutaneous mitral valve repair by edge-to-edge device: when the strategy fails in the highest risk surgical population.

    PubMed

    Alozie, Anthony; Westphal, Bernd; Kische, Stephan; Kaminski, Alexander; Paranskaya, Liliya; Bozdag-Turan, Ilkay; Ortak, Jasmin; Schubert, Jochen; Steinhoff, Gustav; Ince, Hüseyin

    2014-07-01

    Percutaneous edge-to-edge devices for non-surgical repair of mitral valve regurgitation are under clinical evaluation in high-risk patients deemed not suitable for conventional surgery. To address guidelines for initial therapy decision, we here report on 13 cases of surgery after failed percutaneous edge-to-edge mitral valve repair or attempted repair, and discuss methodology and prognostic factors for operative outcome in this high-risk situation. Thirteen patients referred to our cardiothoracic unit after failed percutaneous mitral valve repair or attempted repair using the edge-to-edge technique, were treated surgically for mitral valve failure between June 2010 and December 2012. Pathology of mitral valve before and after interventional mitral valve repair (especially prevalent mode of failure) was evaluated and classified for each individual patient by echocardiography and intraoperative direct visualization. Number of implanted edge-to-edge devices were identified. Preoperative risk scores were matched with intraoperative observations and histopathological findings of valve tissue. Postoperative morbidity and mortality were analysed with respect to mitral valve and patient-related data. Three of 10 patients were referred with severe mitral valve regurgitation/stenosis after initially successful percutaneous edge-to-edge therapy or attempted therapy. In 3 patients, ≥ 2 edge-to-edge devices were implanted leading to very tight edge-to-edge leaflet connection and fibrosis. All patients underwent successful surgical mitral valve replacement and concomitant complete cardiac surgery (CABG, aortic or tricuspid valve surgery, ASD closure and pulmonary vein isolation for atrial fibrillation). The likelihood of repair was reduced with respect to multiple edge-to-edge technology. One device could not be harvested surgically because of embolization. One patient died on the second postoperative day due to sepsis with multiple organ failure. The remaining 12 patients were discharged with excellent valve prosthesis function and followed up to 2 years post-surgery. The current long-term survival rate is 77%. Our series demonstrate that highest risk patients can survive mitral valve surgery after failed multiple edge-to-edge interventional mitral valve repair. As long-term results of the MitraClip therapy are pending, we recommend close meshed follow-up of patients treated with the MitraClip device, especially within the first year of the index procedure as delays in salvage management, interventional or surgical, when the index procedure fails may increase morbidity and mortality. © The Author 2013. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  2. Surgical flow modification of the anterior cerebral artery-anterior communicating artery complex in the management of giant aneurysms of internal carotid artery bifurcation: An alternative for a difficult clip reconstruction

    PubMed Central

    Pahl, Felix Hendrik; de Oliveira, Matheus Fernandes; Beer-Furlan, André Luiz; Rotta, José Marcus

    2016-01-01

    Background: Internal carotid artery bifurcation (ICAb) aneurysms account for about 2–15% of all intracranial aneurysms. In giant and complex cases, treatment may be difficult and dangerous, once some aneurysms have wide neck and anterior cerebral artery (ACA) and middle cerebral artery (MCA) may arise from the aneurysm itself. Clip reconstruction may be difficult in such cases. Whenever possible, the occlusion of ACA transform the bifurcation in a single artery reconstruction (ICA to MCA), much easier than a bifurcation reconstruction. Methods: In patients with giant and complex ICAb aneurysms, we propose routine preoperative angiography with anatomical evaluation of anterior communicating artery (ACoA) patency during cervical common carotid compression with concomitant contralateral carotid artery injection. This allowed visualization of the expected reversal of flow in the A1 segment–ACoA complex. When test is positive, we can perform ipsilateral ACA (A1 segment) clip occlusion and flow modification of the ACA-ACoA complex transforming a three vessel (ICA, ACA, and MCA) reconstruction into a two vessel (ICA and MCA) reconstruction. Results: Two patients were treated, with 100% of occlusion and good outcome. Conclusions: Surgical treatment of giant and complex ICAb may be achieved with acceptable morbidity. PMID:27313968

  3. Introduction: Intradural Spinal Surgery video supplement.

    PubMed

    McCormick, Paul C

    2014-09-01

    This Neurosurgical Focus video supplement contains detailed narrated videos of a broad range of intradural pathology such as neoplasms, including intramedullary, extramedullary, and dumbbell tumors, vascular malformations, functional disorders, and rare conditions that are often overlooked or misdiagnosed such as arachnoid cysts, ventral spinal cord herniation, and dorsal arachnoid web. The intent of this supplement is to provide meaningful educational and instructional content at all levels of training and practice. As such, the selected video submissions each provide a comprehensive detailed narrative description and coordinated video that contains the entire spectrum of relevant information including imaging, operative setup and positioning, and exposure, as well as surgical strategies, techniques, and sequencing toward the safe and effective achievement of the operative objective. This level of detail often necessitated a more lengthy video duration than is typically presented in oral presentations or standard video clips from peer reviewed publications. Unfortunately, space limitations precluded the inclusion of several other excellent video submissions in this supplement. While most videos in this supplement reflect standard operative approaches and techniques there are also submissions that describe innovative exposures and techniques that have expanded surgical options such as ventral approaches, stereotactic guidance, and minimally invasive exposures. There is some redundancy in both the topics and techniques both to underscore fundamental surgical principles as well as to provide complementary perspective from different surgeons. It has been my privilege to serve as guest editor for this video supplement and I would like to extend my appreciation to Mark Bilsky, Bill Krauss, and Sander Connolly for reviewing the large number submitted videos. Most of all, I would like to thank the authors for their skill and effort in the preparation of the outstanding videos that constitute this video supplement.

  4. Keyhole concept in cerebral aneurysm clipping and tumor removal by the supraciliary lateral supraorbital approach

    PubMed Central

    Mori, Kentaro

    2014-01-01

    The keyhole concept in neurosurgery is designed to minimize the craniotomy needed for the access route to deep intracranial pathologies. Such keyhole surgeries cause less trauma and can be less invasive than conventional surgical techniques. Among the various types of keyhole mini-craniotomy, supraorbital or lateral supraorbital mini-craniotomy is the standard and basic keyhole approaches. The lateral supraorbital keyhole provides adequate working space in the suprasellar to parasellar areas and planum sphenoidale area including the anterior communicating artery complex. Despite the development of neuro-endoscopic techniques and intra-operative assistant methods, the limited working angle to manipulate and observe deeply situated pathologies is a major disadvantage of the keyhole approaches. Neurosurgeons should understand that keyhole mini-craniotomy surgeries aim at “minimally invasive neurosurgery” but still carry the risks of malpractice unless we understand the advantages and disadvantages of these keyhole concepts and strategies. PMID:24891885

  5. Laparoscopic uterine artery occlusion for symptomatic leiomyomas.

    PubMed

    Lichtinger, Moises; Hallson, Laurey; Calvo, Patricia; Adeboyejo, Ghea

    2002-05-01

    To describe a laparoscopic technique that safely occludes both uterine arteries, overcoming an altered surgical field resulting from scarring and/or uterine leiomyomatous growth. Prospective analysis (Canadian Task Force classification II-2). Nonprofit community hospital. Eight women with leiomyomas with abnormal uterine bleeding, pelvic pain or pressure, and/or anemia. Bilateral laparoscopic retroperitoneal uterine artery occlusion. Occlusion at the initial track of the uterine artery was performed by laparoscopic coated ligature in six patients. In two obese patients with deep retroperitoneal space, vascular clips were placed endoscopically using the same dissecting technique. All patients were discharged within 20 hours after the procedure. All five women with abnormal bleeding reported satisfactory decrease; none reported amenorrhea. Of eight with preoperative pain or pressure, seven reported complete disappearance and one significant relief. All three patients with anemia had normal red cell counts after 1 month. Laparoscopic uterine artery occlusion using a lateral retroperitoneal technique is safe and effective in women with pelvic scarring and altered pelvic anatomy.

  6. Safety and efficacy of endoscopic submucosal dissection using IT knife nano with clip traction method for early esophageal squamous cell carcinoma.

    PubMed

    Kitagawa, Yoshiyasu; Suzuki, Takuto; Hara, Taro; Yamaguchi, Taketo

    2018-01-01

    Although endoscopic submucosal dissection (ESD) is an accepted and established treatment for early esophageal squamous cell carcinoma (EESCC), it is technically difficult, time consuming, and less safe than endoscopic mucosal resection. To perform ESD safely and more efficiently, we proposed a new technique of esophageal ESD using an IT knife nano with the clip traction method. This study aimed to evaluate the efficacy and safety of ESD using this new technique. We retrospectively reviewed all consecutive cases of esophageal ESD performed using an IT knife nano with the clip traction method at our hospital between March 2013 and January 2017. Therapeutic efficacy and safety were also assessed. A total of 103 patients underwent esophageal ESD using the IT knife nano with the clip traction method. In all cases, we performed en bloc resection. Complete resection was achieved in 100 cases (97.1%). The median operating time was 40 (range 13-230) min. No cases of perforation or delayed bleeding occurred. Although two cases (2.0%) of mediastinal emphysema occurred without visible perforation at endoscopy, all were successfully managed conservatively. The new technique of esophageal ESD using the IT knife nano with the clip traction method appears to be feasible, effective, and safe for EESCC treatment.

  7. Mitral stenosis due to dynamic clip-leaflet interaction during the MitraClip procedure: Case report and review of current knowledge.

    PubMed

    Singh, Gagan D; Smith, Thomas W; Rogers, Jason H

    2017-06-01

    The goal of MitraClip therapy is to achieve mitral regurgitation reduction without iatrogenic creation of clinically significant MS. In some series, up to 35% of patients are left with mild MS. There are many contributors to the final transmitral gradient achieved in patients undergoing MitraClip therapy. Additionally, there are many modalities used for the intraprocedural assessment of MS with no one modality considered to be the benchmark. We herein describe a case which illustrates the dynamic nature of clip-leaflet interaction, and review intraprocedural techniques for invasively and noninvasively assessing MS. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. Percutaneous Tricuspid Valve Regurgitation Repair With the MitraClip Device Using an Edge-to-Edge Bicuspidization Technique.

    PubMed

    Gafoor, Sameer; Petrescu, O Madalina; Lehr, Eric J; Puls, Charles; Zhang, Ming; Petersen, John L; Olsen, John V; Penev, Irina; Agrawal, Mayank; Sharma, Rahul; Barnhart, Glenn

    2017-03-01

    Patients who present with both severe mitral and tricuspid regurgitation who are symptomatic despite optimal medical therapy and at prohibitive risk for surgery pose a significant therapeutic challenge. The MitraClip device (Abbott Vascular) is approved for percutaneous mitral valve repair in high-risk and non-operative patients, and has also been used for tricuspid valve repair. Imaging support for percutaneous edge-to-edge tricuspid valve repair has not been reported and is a vital part of the procedure. Here, we present a periprocedural imaging strategy for percutaneous tricuspid valve repair with the MitraClip device using a bicuspidization technique.

  9. Interhemispheric Information Transfer: A New Diagnostic Method for Mild Traumatic Brain Injury

    DTIC Science & Technology

    2011-10-01

    brain tumors, meningitis, cerebral palsy, encephalitis, brain abscesses , vascular malformations, cerebrovascular disease, Alzheimer’s disease...disease including head trauma with loss of consciousness 2) Having a contraindication to MRI such as pregnancy, breast feeding, surgical clips

  10. Teaching Surgical Procedures with Movies: Tips for High-quality Video Clips

    PubMed Central

    Jacquemart, Mathieu; Bouletreau, Pierre; Breton, Pierre; Mojallal, Ali

    2016-01-01

    Summary: Video must now be considered as a precious tool for learning surgery. However, the medium does present production challenges, and currently, quality movies are not always accessible. We developed a series of 7 surgical videos and made them available on a publicly accessible internet website. Our videos have been viewed by thousands of people worldwide. High-quality educational movies must respect strategic and technical points to be reliable. PMID:27757342

  11. Influence of percutaneous mitral valve repair using the MitraClip® system on renal function in patients with severe mitral regurgitation.

    PubMed

    Rassaf, Tienush; Balzer, Jan; Rammos, Christos; Zeus, Tobias; Hellhammer, Katharina; v Hall, Silke; Wagstaff, Rabea; Kelm, Malte

    2015-04-01

    In patients with mitral regurgitation (MR), changes in cardiac stroke volume, and thus renal preload and afterload may affect kidney function. Percutaneous mitral valve repair (PMVR) with the MitraClip® system can be a therapeutic alternative to surgical valve repair. The influence of MitraClip® therapy on renal function and clinical outcome parameters is unknown. Sixty patients with severe MR underwent PMVR using the MitraClip® system in an open-label observational study. Patients were stratified according to their renal function. All clips have been implanted successfully. Effective reduction of MR by 2-3 grades acutely improved KDOQI class. Lesser MR reduction (MR reduction of 0-1 grades) led to worsening of renal function in patients with pre-existing normal or mild (KDOQI 1-2) compared to severe (KDOQI 3-4) renal dysfunction. Reduction of MR was associated with improvement in Minnesota Living with Heart Failure Questionnaire (MLHFQ), NYHA-stadium, and 6-minute walk test. Successful PMVR was associated with an improvement in renal function. The improvement in renal function was associated with the extent of MR reduction and pre-existing kidney dysfunction. Our data emphasize the relevance of PVMR to stabilize the cardiorenal axis in patients with severe MR. © 2014 Wiley Periodicals, Inc.

  12. Surgical outcomes of Majewski osteodysplastic primordial dwarfism Type II with intracranial vascular anomalies.

    PubMed

    Teo, Mario; Johnson, Jeremiah N; Bell-Stephens, Teresa E; Marks, Michael P; Do, Huy M; Dodd, Robert L; Bober, Michael B; Steinberg, Gary K

    2016-12-01

    OBJECTIVE Majewski osteodysplastic primordial dwarfism Type II (MOPD II) is a rare genetic disorder. Features of it include extremely small stature, severe microcephaly, and normal or near-normal intelligence. Previous studies have found that more than 50% of patients with MOPD II have intracranial vascular anomalies, but few successful surgical revascularization or aneurysm-clipping cases have been reported because of the diminutive arteries and narrow surgical corridors in these patients. Here, the authors report on a large series of patients with MOPD II who underwent surgery for an intracranial vascular anomaly. METHODS In conjunction with an approved prospective registry of patients with MOPD II, a prospectively collected institutional surgical database of children with MOPD II and intracranial vascular anomalies who underwent surgery was analyzed retrospectively to establish long-term outcomes. RESULTS Ten patients with MOPD II underwent surgery between 2005 and 2012; 5 patients had moyamoya disease (MMD), 2 had intracranial aneurysms, and 3 had both MMD and aneurysms. Patients presented with transient ischemic attack (TIA) (n = 2), ischemic stroke (n = 2), intraparenchymal hemorrhage from MMD (n = 1), and aneurysmal subarachnoid hemorrhage (n = 1), and 4 were diagnosed on screening. The mean age of the 8 patients with MMD, all of whom underwent extracranial-intracranial revascularization (14 indirect, 1 direct) was 9 years (range 1-17 years). The mean age of the 5 patients with aneurysms was 15.5 years (range 9-18 years). Two patients experienced postoperative complications (1 transient weakness after clipping, 1 femoral thrombosis that required surgical repair). During a mean follow-up of 5.9 years (range 3-10 years), 3 patients died (1 of subarachnoid hemorrhage, 1 of myocardial infarct, and 1 of respiratory failure), and 1 patient had continued TIAs. All of the surviving patients recovered to their neurological baseline. CONCLUSIONS Patients with MMD presented at a younger age than those in whom aneurysms were more prevalent. Microneurosurgery with either intracranial bypass or aneurysm clipping is extremely challenging but feasible at expert centers in patients with MOPD II, and good long-term outcomes are possible.

  13. A New Sliding-Loop Technique in Renorrhaphy for Partial Nephrectomy: A Feasibility Study in a Porcine Model.

    PubMed

    Lee, Jung Keun; Oh, Jong Jin; Lee, Sangchul; Lee, Seung Bae; Byun, Seok-Soo; Lee, Sang Eun; Jeong, Chang Wook

    2016-04-01

    We developed a sliding-loop technique that narrowed both sides of the parenchyma in a porcine model and compared it with the conventional sliding-clip technique. Three pigs (30-40 kg) were reused following another experiment conducted by the same researchers. Bilateral kidneys were harvested within 30 minutes after euthanasia. Two partial nephrectomies per kidney were performed on opposite surfaces. All kidney defects were of the same size (diameter of 2.5-3 cm with a depth of 1.0-1.5 cm). The sliding-clip technique and sliding-loop technique were performed separately. In the sliding-loop technique, we created a 1-cm loop at the end of a Vicryl and placed a tetrafluoroethylene polymer pledget in front of the knots passing through the needle. The needle then crossed the loop after passing through the renal parenchyma. A Weck clip was placed and slid on one side to tighten the suture. Tightening was controlled with an equivalent force using a digital push-pull gauge. Three stitches were placed at each renorrhaphy site. The distance between repaired renal surfaces was measured at 5 different points (3 suture sites and 2 middle sites between sutures). The results of the 2 techniques were compared by using the independent t test. The mean distance between renal surfaces was significantly narrower in the sliding-loop technique than in the conventional technique (1.80 ± 1.08 mm vs 5.28 ± 2.46 mm, P < .001). In the porcine model, the sliding-loop technique more effectively closed the partial nephrectomy defects compared with the conventional sliding-clip technique. © The Author(s) 2015.

  14. Surgical transposition of the ovaries: imaging findings in 14 patients.

    PubMed

    Kier, R; Chambers, S K

    1989-11-01

    Pelvic radiation therapy for cervical or vaginal cancer often leads to ovarian failure. To remove the ovaries from the radiation portal and preserve their function, they can be transposed to the lateral abdomen. Serial imaging studies in 14 patients who had undergone ovarian transposition (five bilateral, nine unilateral) were reviewed. Images obtained included 32 CT scans, 20 sonograms, and one MR image. Most transposed ovaries were located along the paracolic gutters near the iliac crests, creating an extrinsic mass effect on adjacent bowel. Detection of surgical clips on the ovary on CT scans allowed confident recognition of all 19 transposed ovaries. Cysts in the transposed ovaries, noted on most imaging studies, did not correlate with complications of pain or hormonal dysfunction. In one case, a large physiologic cyst in a transposed ovary distorted the cecum and was mistaken for a mucocele of the appendix. In another case, a large ovarian cyst was thought to be tumor recurrence or a lymphocele. These findings indicate that although the transposed ovaries can be recognized on CT scans by the surgical clips attached to the ovaries, the appearance of the ovary does not predict reliably the development of complications.

  15. Flexible Ultrathin Endoscope Integrated with Irrigation Suction Apparatus for Assisting Microneurosurgery.

    PubMed

    Otani, Naoki; Morimoto, Yuji; Fujii, Kazuya; Toyooka, Terushige; Wada, Kojiro; Mori, Kentaro

    2017-12-01

    Endoscopy can observe the anatomical components in a deeply located and/or hidden area during neurosurgical procedures under the operating microscope. We have newly developed a flexible ultrathin endoscope integrated with irrigation suction apparatus (FUEISA) to visualize deeply located and/or hidden areas for assisting microneurosurgery. The present study investigated the usefulness of the FUEISA system for direct clipping surgery of cerebral aneurysms. Twenty-one patients underwent microneurosurgery assisted with the FUEISA system for direct clipping of cerebral aneurysms. The flexible ultrathin endoscope (outer diameter 0.75mm) consists of an image guide (6000 dpi) and a light guide, integrated with the irrigation suction apparatus. This endoscopic system was inserted before and after clipping to observe the anatomical conditions surrounding the lesions. In all cases, handling and operation of the FUEISA was technically successful during the surgical procedure. The ultrathin endoscope was adequately integrated with the irrigation suction apparatus in all cases. General anatomy visualization including the lenticulostriate arteries, medial striate arteries, and/or internal carotid artery perforators was possible, and the correct clip positioning and vessel conditions were easily checked. The endoscope revealed that the clip had been positioned incorrectly in one case. No complications associated with the endoscopic system occurred. The FUEISA system can be applied with safe manipulation, which was remarkably useful for confirmation of the presence of perforators and cranial nerves behind the lesions, particularly anatomical components located in deep and/or hidden areas during clipping of cerebral aneurysms. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. Evaluation of Clipping Based Iterative PAPR Reduction Techniques for FBMC Systems

    PubMed Central

    Kollár, Zsolt

    2014-01-01

    This paper investigates filter bankmulticarrier (FBMC), a multicarrier modulation technique exhibiting an extremely low adjacent channel leakage ratio (ACLR) compared to conventional orthogonal frequency division multiplexing (OFDM) technique. The low ACLR of the transmitted FBMC signal makes it especially favorable in cognitive radio applications, where strict requirements are posed on out-of-band radiation. Large dynamic range resulting in high peak-to-average power ratio (PAPR) is characteristic of all sorts of multicarrier signals. The advantageous spectral properties of the high-PAPR FBMC signal are significantly degraded if nonlinearities are present in the transceiver chain. Spectral regrowth may appear, causing harmful interference in the neighboring frequency bands. This paper presents novel clipping based PAPR reduction techniques, evaluated and compared by simulations and measurements, with an emphasis on spectral aspects. The paper gives an overall comparison of PAPR reduction techniques, focusing on the reduction of the dynamic range of FBMC signals without increasing out-of-band radiation. An overview is presented on transmitter oriented techniques employing baseband clipping, which can maintain the system performance with a desired bit error rate (BER). PMID:24558338

  17. Minimizing hair dispersal: Is this an opportunity for improvement in health care-acquired infection prevention?

    PubMed

    Mantyh, Christopher R; Xi, Hugo; Pearson, Lena; Perl, Trish M

    2017-03-01

    We performed a study to understand common practices in surgical site hair removal and barriers to guideline compliance in surgical site hair removal. We found most health care providers in the United States do not remove hair outside of the operating room. Our findings reveal minimizing hair dispersal in the operating room, including improved and innovative ways for collecting clipped loose hair, is a significant area for improvement in surgical quality and health care-acquired infection prevention. Copyright © 2017 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  18. Evaluation of stereoscopic medical video content on an autostereoscopic display for undergraduate medical education

    NASA Astrophysics Data System (ADS)

    Ilgner, Justus F. R.; Kawai, Takashi; Shibata, Takashi; Yamazoe, Takashi; Westhofen, Martin

    2006-02-01

    Introduction: An increasing number of surgical procedures are performed in a microsurgical and minimally-invasive fashion. However, the performance of surgery, its possibilities and limitations become difficult to teach. Stereoscopic video has evolved from a complex production process and expensive hardware towards rapid editing of video streams with standard and HDTV resolution which can be displayed on portable equipment. This study evaluates the usefulness of stereoscopic video in teaching undergraduate medical students. Material and methods: From an earlier study we chose two clips each of three different microsurgical operations (tympanoplasty type III of the ear, endonasal operation of the paranasal sinuses and laser chordectomy for carcinoma of the larynx). This material was added by 23 clips of a cochlear implantation, which was specifically edited for a portable computer with an autostereoscopic display (PC-RD1-3D, SHARP Corp., Japan). The recording and synchronization of left and right image was performed at the University Hospital Aachen. The footage was edited stereoscopically at the Waseda University by means of our original software for non-linear editing of stereoscopic 3-D movies. Then the material was converted into the streaming 3-D video format. The purpose of the conversion was to present the video clips by a file type that does not depend on a television signal such as PAL or NTSC. 25 4th year medical students who participated in the general ENT course at Aachen University Hospital were asked to estimate depth clues within the six video clips plus cochlear implantation clips. Another 25 4th year students who were shown the material monoscopically on a conventional laptop served as control. Results: All participants noted that the additional depth information helped with understanding the relation of anatomical structures, even though none had hands-on experience with Ear, Nose and Throat operations before or during the course. The monoscopic group generally estimated resection depth to much lesser values than in reality. Although this was the case with some participants in the stereoscopic group, too, the estimation of depth features reflected the enhanced depth impression provided by stereoscopy. Conclusion: Following first implementation of stereoscopic video teaching, medical students who are inexperienced with ENT surgical procedures are able to reproduce depth information and therefore anatomically complex structures to a greater extent following stereoscopic video teaching. Besides extending video teaching to junior doctors, the next evaluation step will address its effect on the learning curve during the surgical training program.

  19. Dosimetric impact of tumor bed delineation variability based on 4DCT scan for external-beam partial breast irradiation.

    PubMed

    Guo, Bing; Li, Jianbin; Wang, Wei; Li, Fengxiang; Guo, Yanluan; Li, Yankang; Liu, Tonghai

    2015-01-01

    This study sought to evaluate the dosimetric impact of tumor bed delineation variability (based on clips, seroma or both clips and seroma) during external-beam partial breast irradiation (EB-PBI) planned utilizing four-dimensional computed tomography (4DCT) scans. 4DCT scans of 20 patients with a seroma clarity score (SCS) 3~5 and ≥5 surgical clips were included in this study. The combined volume of the tumor bed formed using clips, seroma, or both clips and seroma on the 10 phases of 4DCT was defined as the internal gross target volume (termed IGTVC, IGTVS and IGTVC+S, respectively). A 1.5-cm margin was added by defining the planning target volume (termed PTVC, PTVS and PTVC+S, respectively). Three treatment plans were established using the 4DCT images (termed EB-PBIC, EB-PBIS, EB-PBIC+S, respectively). The results showed that the volume of IGTVC+S was significantly larger than that of IGTVCand IGTVS. Similarly, the volume of PTVC+S was markedly larger than that of PTVC and PTVS. However, the PTV coverage for EB-PBIC+S was similar to that of EB-PBIC and EB-PBIS, and there were no significant differences in the homogeneity index or conformity index between the three treatment plans (P=0.878, 0.086). The EB-PBIS plan resulted in the lowest ipsilateral normal breast and ipsilateral lung doses compared with the EB-PBIC and EB-PBIC+S plans. To conclude, the volume variability delineated based on clips, seroma or both clips and seroma resulted in dosimetric variability for organs at risk, but did not show a marked influence on the dosimetric distribution.

  20. Dosimetric impact of tumor bed delineation variability based on 4DCT scan for external-beam partial breast irradiation

    PubMed Central

    Guo, Bing; Li, Jianbin; Wang, Wei; Li, Fengxiang; Guo, Yanluan; Li, Yankang; Liu, Tonghai

    2015-01-01

    This study sought to evaluate the dosimetric impact of tumor bed delineation variability (based on clips, seroma or both clips and seroma) during external-beam partial breast irradiation (EB-PBI) planned utilizing four-dimensional computed tomography (4DCT) scans. 4DCT scans of 20 patients with a seroma clarity score (SCS) 3~5 and ≥5 surgical clips were included in this study. The combined volume of the tumor bed formed using clips, seroma, or both clips and seroma on the 10 phases of 4DCT was defined as the internal gross target volume (termed IGTVC, IGTVS and IGTVC+S, respectively). A 1.5-cm margin was added by defining the planning target volume (termed PTVC, PTVS and PTVC+S, respectively). Three treatment plans were established using the 4DCT images (termed EB-PBIC, EB-PBIS, EB-PBIC+S, respectively). The results showed that the volume of IGTVC+S was significantly larger than that of IGTVCand IGTVS. Similarly, the volume of PTVC+S was markedly larger than that of PTVC and PTVS. However, the PTV coverage for EB-PBIC+S was similar to that of EB-PBIC and EB-PBIS, and there were no significant differences in the homogeneity index or conformity index between the three treatment plans (P=0.878, 0.086). The EB-PBIS plan resulted in the lowest ipsilateral normal breast and ipsilateral lung doses compared with the EB-PBIC and EB-PBIC+S plans. To conclude, the volume variability delineated based on clips, seroma or both clips and seroma resulted in dosimetric variability for organs at risk, but did not show a marked influence on the dosimetric distribution. PMID:26885108

  1. Cerebral Protection During MitraClip Implantation: Initial Experience at 2 Centers.

    PubMed

    Frerker, Christian; Schlüter, Michael; Sanchez, Oscar D; Reith, Sebastian; Romero, Maria E; Ladich, Elena; Schröder, Jörg; Schmidt, Tobias; Kreidel, Felix; Joner, Michael; Virmani, Renu; Kuck, Karl-Heinz

    2016-01-25

    This study sought to assess the feasibility and safety of using a filter-based cerebral protection system (CPS) during MitraClip implantation and to report on the histopathologic analysis of the captured debris. Stroke is one of the serious adverse events associated with MitraClip therapy. Between July 2014 and March 2015, 14 surgical high-risk patients (age 75 ± 7 years; 7 men; median logistic EuroSCORE 21%) underwent MitraClip implantation employing cerebral protection with a dual embolic filter system. All patients had severe mitral regurgitation of predominantly functional origin. All procedures were successfully completed for both CPS deployment/retrieval and MitraClip implantation. A total of 28 filters (2 from each patient) were analyzed. Microscopically, debris was identified in all 14 patients. The most common tissue types were acute thrombus and small fragments of foreign material, which were found in 12 patients (85.7%) each. Organizing thrombus was present in 4 patients (28.6%), valve tissue and/or superficial atrial wall tissue in 9 patients (64.3%), and fragments of myocardium in 2 patients (14.3%). No transient ischemic attacks, strokes, or deaths occurred peri-procedurally or during a median follow-up interval of 8.4 months. In this small study of patients undergoing MitraClip treatment with cerebral protection, embolic debris potentially conducive to cerebrovascular events was found in all patients. Debris was composed most often of acute thrombus, foreign material likely originating from the hydrophilic device coating, and valve/atrial wall tissue. Further studies are warranted to assess the impact of cerebral protection on the incidence of cerebrovascular events after MitraClip therapy. Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  2. Harmonic scalpel in multinodular goiter surgery: impact on surgery and cost analysis.

    PubMed

    Sebag, Frederic; Fortanier, Cécile; Ippolito, Guiseppe; Lagier, Aude; Auquier, Pascal; Henry, Jean-Francois

    2009-04-01

    The aim of this study was to evaluate the potential advantages and the general operative cost of the Harmonic Scalpel (HS) in surgery for multinodular goiter (MNG). Patients undergoing total thyroidectomy (TT) for MNG were prospectively allocated in a conventional tie-and-clip (TC) group (n = 50) and an HS group (n = 50). All pre- and postoperative data were recorded. The economic evaluation was based on a microcost measurement and aimed to consider all the resources consumed for each patient during the surgical procedure. To compare the results, we used the nonparametric unpaired two-tailed Mann-Whitney test. There were 81 women and 19 men (mean age, 55 +/- 15 years). Mean preoperative TSH level was 1.2 (SD, 1.1) (TC) and 1.3 (SD, 2) (HS) (P = NS). Mean body mass index was 24.72 (SD, 8) (TC) and 25.6 (SD, 8) (HS) (P = NS). Four patients experienced a transient hypocalcemia (2 in each group). One patient had a postoperative hematoma requiring surgical evacuation (HS). One patient experienced a transient recurrent nerve palsy (TC). Mean length of surgery was 104 (SD, 32) (TC) and 84 minutes (SD, 17) (HS) (P = .0001). Mean length of hospitalization was 2 days in both groups (SD, 1) (P = NS). Mean operative cost per patient was 990 euro (SD, 191) in the TC group and 1,024 euro (SD, 143) in the HS group (P = NS). Safety and efficiency of the HS is comparable to the tie-and-clip technique in thyroid surgery. The use of the HS in MNG surgery allows for a significant reduction in the length of the procedure with a comparable cost.

  3. Rule groupings in expert systems using nearest neighbour decision rules, and convex hulls

    NASA Technical Reports Server (NTRS)

    Anastasiadis, Stergios

    1991-01-01

    Expert System shells are lacking in many areas of software engineering. Large rule based systems are not semantically comprehensible, difficult to debug, and impossible to modify or validate. Partitioning a set of rules found in CLIPS (C Language Integrated Production System) into groups of rules which reflect the underlying semantic subdomains of the problem, will address adequately the concerns stated above. Techniques are introduced to structure a CLIPS rule base into groups of rules that inherently have common semantic information. The concepts involved are imported from the field of A.I., Pattern Recognition, and Statistical Inference. Techniques focus on the areas of feature selection, classification, and a criteria of how 'good' the classification technique is, based on Bayesian Decision Theory. A variety of distance metrics are discussed for measuring the 'closeness' of CLIPS rules and various Nearest Neighbor classification algorithms are described based on the above metric.

  4. Management of a large mucosal defect after duodenal endoscopic resection

    PubMed Central

    Fujihara, Shintaro; Mori, Hirohito; Kobara, Hideki; Nishiyama, Noriko; Matsunaga, Tae; Ayaki, Maki; Yachida, Tatsuo; Masaki, Tsutomu

    2016-01-01

    Duodenal endoscopic resection is the most difficult type of endoscopic treatment in the gastrointestinal tract (GI) and is technically challenging because of anatomical specificities. In addition to these technical difficulties, this procedure is associated with a significantly higher rate of complication than endoscopic treatment in other parts of the GI tract. Postoperative delayed perforation and bleeding are hazardous complications, and emergency surgical intervention is sometimes required. Therefore, it is urgently necessary to establish a management protocol for preventing serious complications. For instance, the prophylactic closure of large mucosal defects after endoscopic resection may reduce the risk of hazardous complications. However, the size of mucosal defects after endoscopic submucosal dissection (ESD) is relatively large compared with the size after endoscopic mucosal resection, making it impossible to achieve complete closure using only conventional clips. The over-the-scope clip and polyglycolic acid sheets with fibrin gel make it possible to close large mucosal defects after duodenal ESD. In addition to the combination of laparoscopic surgery and endoscopic resection, endoscopic full-thickness resection holds therapeutic potential for difficult duodenal lesions and may overcome the disadvantages of endoscopic resection in the near future. This review aims to summarize the complications and closure techniques of large mucosal defects and to highlight some directions for management after duodenal endoscopic treatment. PMID:27547003

  5. Safe procedure in endoscopic submucosal dissection for colorectal tumors focused on preventing complications

    PubMed Central

    Yoshida, Naohisa; Yagi, Nobuaki; Naito, Yuji; Yoshikawa, Toshikazu

    2010-01-01

    Endoscopic submucosal dissection (ESD) is efficient for en bloc resection of large colorectal tumors. However, it has several technical difficulties, because the wall of the colon is thin and due to the winding nature of the colon. The main complications of ESD comprise postoperative perforation and hemorrhage, similar to endoscopic mucosal resection (EMR). In particular, the rate of perforation in ESD is higher than that in EMR. Perforation of the colon can cause fatal peritonitis. Endoscopic clipping is reported to be an efficient therapy for perforation. Most cases with perforation are treated conservatively without urgent surgical intervention. However, the rate of postoperative hemorrhage in ESD is similar to that in EMR. Endoscopic therapy including endoscopic clipping is performed and most of the cases are treated conservatively without blood transfusion. In blood examination, some degree of inflammation is detected after ESD. For the standardization of ESD, it is most important to decrease the rate of perforation. Adopting a safe strategy for ESD and a suitable choice of knife are both important ways of preventing perforation. Moreover, appropriate training and increasing experience can improve the endoscopic technique and can decrease the rate of perforation. In this review, we describe safe procedures in ESD to prevent complications, the complications of ESD and their management. PMID:20379999

  6. Hemodynamic response during aneurysm clipping surgery among experienced neurosurgeons.

    PubMed

    Bunevicius, Adomas; Bilskiene, Diana; Macas, Andrius; Tamasauskas, Arimantas

    2016-02-01

    Neurosurgery is a challenging field associated with high levels of mental stress. The goal of this study was to investigate the hemodynamic response of experienced neurosurgeons during aneurysm clipping surgery and to evaluate whether neurosurgeons' hemodynamic responses are associated with patients' clinical statuses. Four vascular neurosurgeons (all male; mean age 51 ± 10 years; post-residency experience ≥7 years) were studied during 42 aneurysm clipping procedures. Blood pressure (BP) and heart rate (HR) were assessed at rest and during seven phases of surgery: before the skin incision, after craniotomy, after dural opening, after aneurysm neck dissection, after aneurysm clipping, after dural closure and after skin closure. HR and BP were significantly greater during surgery relative to the rest situation (p ≤ 0.03). There was a statistically significant increase in neurosurgeons' HR (F [6, 41] = 10.88, p < 0.001), systolic BP (F [6, 41] = 2.97, p = 0.01), diastolic BP (F [6, 41] = 2.49, p = 0.02) and mean BP (F [6, 41] = 3.36, p = 0.003) during surgery. The greatest mean HR was after aneurysm clipping, and the greatest BP was after aneurysm neck dissection. Systolic, diastolic and mean BPs were significantly greater during surgical clipping for unruptured aneurysms compared to ruptured aneurysms across all stages of surgery (p ≤ 0.002); however, after adjusting for neurosurgeon experience, the difference in BP as a function of aneurysm rupture was not significant (p > 0.08). Aneurysm location, intraoperative aneurysm rupture, admission WFNS score, admission Glasgow Coma Scale scores and Fisher grade were not associated with neurosurgeons' intraoperative HR and BP (all p > 0.07). Aneurysm clipping surgery is associated with significant hemodynamic system activation among experienced neurosurgeons. The greatest HR and BP were after aneurysm neck dissection and clipping. Aneurysm location and patient clinical status were not associated with intraoperative changes of neurosurgeons' HR and BP.

  7. From tails to toes: developing nonlethal tissue indicators of mercury exposure in five amphibian species.

    PubMed

    Pfleeger, Adam Z; Eagles-Smith, Collin A; Kowalski, Brandon M; Herring, Garth; Willacker, James J; Jackson, Allyson K; Pierce, John R

    2016-04-01

    Exposure to environmental contaminants has been implicated as a factor in global amphibian decline. Mercury (Hg) is a particularly widespread contaminant that biomagnifies in amphibians and can cause a suite of deleterious effects. However, monitoring contaminant exposure in amphibian tissues may conflict with conservation goals if lethal take is required. Thus, there is a need to develop non-lethal tissue sampling techniques to quantify contaminant exposure in amphibians. Some minimally invasive sampling techniques, such as toe-clipping, are common in population-genetic research, but it is unclear if these methods can adequately characterize contaminant exposure. We examined the relationships between mercury (Hg) concentrations in non-lethally sampled tissues and paired whole-bodies in five amphibian species. Specifically, we examined the utility of three different tail-clip sections from four salamander species and toe-clips from one anuran species. Both tail and toe-clips accurately predicted whole-body THg concentrations, but the relationships differed among species and the specific tail-clip section or toe that was used. Tail-clips comprised of the distal 0-2 cm segment performed the best across all salamander species, explaining between 82 and 92% of the variation in paired whole-body THg concentrations. Toe-clips were less effective predictors of frog THg concentrations, but THg concentrations in outer rear toes accounted for up to 79% of the variability in frog whole-body THg concentrations. These findings suggest non-lethal sampling of tails and toes has potential applications for monitoring contaminant exposure and risk in amphibians, but care must be taken to ensure consistent collection and interpretation of samples.

  8. Unilateral vocal fold paralysis in premature infants after ligation of patent ductus arteriosus: vascular clip versus suture ligature.

    PubMed

    Spanos, William C; Brookes, James T; Smith, Mark C; Burkhart, Harold M; Bell, Edward F; Smith, Richard J H

    2009-10-01

    We investigated risk factors associated with unilateral iatrogenic vocal fold paralysis (IVFP) in the context of ligation of patent ductus arteriosus (PDA) and compared the rates of paralysis between vascular clip and suture ligation procedures. We performed a prospective examination of infants with isolated PDA treated surgically during 1995 to 2005. Statistical significance was determined with a 2-tailed t-test. Of 68 PDA ligations, 13 cases of left-sided IVFP were diagnosed, for an overall incidence of 19%. All cases of IVFP occurred in 55 infants who weighed less than 1 kg at birth. Suture ligature was used in 60% of all PDA ligation patients, and vascular clips in 40%. The incidence of IVFP in patients with vascular clips (19%) was similar to the incidence in those with suture ligature (20%). Hoarseness or stridor was present in 69% of patients with IVFP, compared to 17% of normal controls (p <0.001). The rate of aspiration was not increased in the IVFP group; however, 15% of the patients with IVFP had episodes of decreased oxygen saturation, versus 7% of infants with normal vocal fold mobility. A hoarse infant with a birth weight of less than 1 kg who has undergone PDA ligation should be examined for unilateral IVFP. Vascular clips and suture ligature are associated with similar rates of IVFP.

  9. Development of mitral stenosis after single MitraClip insertion for severe mitral regurgitation.

    PubMed

    Cockburn, James; Fragkou, Paraskevi; Hildick-Smith, David

    2014-02-01

    We report the first case of mitral stenosis following Mitra-Clip insertion in a patient with symptomatic NYHA IV heart failure, secondary to severe mitral regurgitation (MR). A 79-year-old female with a history of prior aortic valve replacement underwent percutaneous mitral valve (MV) repair. A single clip was advanced coaxially down onto the MV under TOE guidance, with the anterior and posterior leaflets clipped together between A2 and P2. TOE confirmed a significant reduction in MR (grade 4 to grade 1). Despite initial symptomatic relief, she represented 3 months later with similar symptoms. Repeat TOE confirmed a well positioned Mitra-Clip with mild residual MR. However, the possibility of significant mitral stenosis was raised due to the presence of significant turbulence through the bi-orifice valve, with a peak gradient of 25 mm Hg. In addition there was evidence of severe functional tricuspid valve (TV) regurgitation with elevated pulmonary artery pressures (PAP 90 mm Hg), confirmed on subsequent right heart catheterization. After repeated heart team discussions and a failure of optimal medical therapy, and despite a logistic EuroScore of 35.5, minimally invasive surgical replacement of the MV and simultaneous TV repair was undertaken via a right thoracotomy. Despite procedural success and initial good postoperative response, the patient died subsequently from a combination of hospital-acquired pneumonia and significant gastrointestinal bleeding (post operative day 35). Mitra-Clip is a promising novel approach to MV repair. The establishment of further clinical and echocardiographic based selection criteria will help identify the correct patients for this treatment. Copyright © 2013 Wiley Periodicals, Inc.

  10. Delayed Visual Loss and Its Surgical Rescue Following Extracranial-Intracranial Arterial Bypass and Native Internal Carotid Artery Sacrifice.

    PubMed

    Li, Lai-Fung; Leung, Gilberto Ka-Kit; Lui, Wai-Man

    2017-02-01

    High-flow extracranial-intracranial (EC-IC) bypass followed by sacrifice of the native internal carotid artery (ICA) is a recognized treatment option for giant ICA aneurysm and skull base tumor involving the ICA. Distal clipping at the supraclinoid portion of the ICA is technically straightforward, but it can potentially compromise ophthalmic artery (OA) perfusion. Because of the extensive EC-IC anastomoses with the OA, visual symptoms are fortunately uncommon. We report a patient who developed complete blindness after distal trapping of the supraclinoid ICA; it was reversed after emergency clip removal. Our patient is a 47-year-old man with recurrent nasopharyngeal carcinoma in close proximity to the left petrosal ICA. The first stage of the procedure involved an EC-IC bypass using radial artery graft, followed by a second stage with combined craniofacial excision. Trapping of the native ICA was achieved using a permanent aneurysm clip placed at the supraclinoid ICA distal to the origin of the OA. He complained of a new onset of complete left eye visual loss approximately 6 hours after the distal aneurysm clip was applied. He was immediately sent to the operating theatre for the removal of the supraclinoid aneurysm clip. On the next day, his vision improved and left pupil became reactive again. OA flow following ICA trapping is complicated and precarious. Delayed onset of visual loss is possible. Prompt action by direct exploration and clip removal is needed and can be effective in reversing blindness. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. Obliteration of a giant fusiform carotid terminus-M1 aneurysm after distal clip application and extracranial-intracranial bypass. Case report.

    PubMed

    Ferroli, P; Ciceri, E; Parati, E; Minati, L; Broggi, G

    2007-06-01

    Giant intracranial aneurysms may not be amenable to direct surgical clipping or endovascular coiling because of three critical factors: 1) lack of clear aneurysmal neck; 2) giant size; 3) involvement with critical perforating or branch vessels. Techniques of flow redirection, however, may offer an alternative treatment strategy for these difficult lesions. In this paper, we report on the use of this alternative strategy in the successful treatment of a left giant fusiform carotid terminus-M1 aneurysm in a 16 year-old boy suffering from Ehler-Danlos disease. This patient was admitted to our Institution because his aneurysm was continuing to be increasing in size, despite a previous ligation of his left cervical ICA which was performed at another institution 2 years earlier after the patient had experienced a hemorrhagic stroke. Upon admission, a neurological examination revealed a slight motor aphasia with mild right hemiparesis, remnant of the ancient stroke. Because of its size and the involvement with M1 perforating arteries, a direct aneurysm attack was deemed inadvisable. After an initial ECA-ICA high flow bypass which spontaneously thrombosed, we performed a repeated high flow bypass with the application of a single clip on M1, right distal to the fusiform dilatation. After an uneventful postoperative course, we were unable to observe any new neurological deficits after surgery. A CT scan on postoperative day 1 revealed that the aneurysm had undergone a spontaneous thrombosis which was completely obliterated at the time of a 6-month follow-up angiogram. At that time, the ECA-ICA bypass was found to be patent. In conclusion the alternative of flow alteration strategies can be successfully used in the treatment of aneurysms that cannot be safely trapped or occluded by traditional neurosurgical methods.

  12. Glaucoma aqueous drainage device erosion repair with buccal mucous membrane grafts.

    PubMed

    Rootman, Dan B; Trope, Graham E; Rootman, David S

    2009-01-01

    Glaucoma aqueous drainage devices are important and effective in the management of recalcitrant glaucoma. One complication of this procedure is erosion and exposure of the tube or plate. Strategies to re-cover glaucoma aqueous drainage devices in such cases have met with variable success. The majority of these interventions use conjunctiva for superficial coverage. However, conjunctiva can be in limited supply, and subject to reerosion. In this report, we discuss the use of oral buccal mucous membrane in combination with a lamellar corneal patch graft for repair of 3 exposed tubes, 2 plates, and a pars plana clip. Mean time to exposure was 4.8 years. Five eyes from 4 patients are presented and the surgical technique is described. Buccal membrane repairs were considered a surgical success in 5 out of 6 cases (83%) with mean follow-up of 1.5 years. We advocate the use of buccal membrane in the repair of glaucoma aqueous drainage device tube/plate erosions in patients for whom local conjunctiva is of variable quality or limited supply. Advantages of this procedure and tissue option are discussed.

  13. University of South Carolina CB Support, Basic Research in Materials and Techniques for Optical Computing Standoff Sensors

    DTIC Science & Technology

    2004-10-01

    chloroform-soaked swab prior to making electrical contact with directly related to the oxidation and reduction potential of the an alligator clip. In...other cases, no cleaning protocol was used emitting layers.’.’ Wrighton et al.𔃺 examined the cyclic and a direct connection via an alligator clip was...applied to optical spectra of complex mix- samples requires techniques of simple multivariate patterntame (gasoline, blood , environmental samples

  14. A neural network simulation package in CLIPS

    NASA Technical Reports Server (NTRS)

    Bhatnagar, Himanshu; Krolak, Patrick D.; Mcgee, Brenda J.; Coleman, John

    1990-01-01

    The intrinsic similarity between the firing of a rule and the firing of a neuron has been captured in this research to provide a neural network development system within an existing production system (CLIPS). A very important by-product of this research has been the emergence of an integrated technique of using rule based systems in conjunction with the neural networks to solve complex problems. The systems provides a tool kit for an integrated use of the two techniques and is also extendible to accommodate other AI techniques like the semantic networks, connectionist networks, and even the petri nets. This integrated technique can be very useful in solving complex AI problems.

  15. PubMed Central

    Bédard, S; Desrochers, A; Fecteau, G; Higgins, R

    2001-01-01

    This study was designed to evaluate 4 preoperative skin preparations, that is, more specifically, to compare the efficacy of chlorhexidine gluconate (CG) and povidone-iodine (PI), as well as 2 hair removal techniques (clipper alone or clipper followed by razor) for preoperative skin preparation in cattle. The 4 protocols resulted in a significant decrease in the number of bacterial colony-forming units (cfu). Group 4 (clipping + shaving + CG) had a significantly lower number of preoperative cfu per gel plate compared with groups 1 (clipping + PI) and 3 (clipping + shaving + PI). Skin reaction frequency was significantly higher in groups 3 and 4 (47.8% for both protocols) than in groups 1 and 2 (clipping + PI or CG) (8.7% for both). Wound infection frequency was 4.3% (4/92) and no significant difference was observed between the 4 treatment groups. The 4 protocols tested were equivalent as to efficacy and satisfactorily decreased skin microflora. Clipping alone was shown to be preferable to clipping plus shaving as a method of hair removal in cattle, with fewer skin reactions and no more wound infections. PMID:11265188

  16. Mesh Displacement After Bilateral Inguinal Hernia Repair With No Fixation

    PubMed Central

    Rocha, Gabriela Moreira; Campos, Antonio Carlos Ligocki; Paulin, João Augusto Nocera; Coelho, Julio Cesar Uili

    2017-01-01

    Background and Objectives: About 20% of patients with inguinal hernia present bilateral hernias in the diagnosis. In these cases, laparoscopic procedure is considered gold standard approach. Mesh fixation is considered important step toward avoiding recurrence. However, because of cost and risk of pain, real need for mesh fixation has been debated. For bilateral inguinal hernias, there are few specific data about non fixation and mesh displacement. We assessed mesh movement in patients who had undergone laparoscopic bilateral inguinal hernia repair without mesh fixation and compared the results with those obtained in patients with unilateral hernia. Methods: From January 2012 through May 2014, 20 consecutive patients with bilateral inguinal hernia underwent TEP repair with no mesh fixation. Results were compared with 50 consecutive patients with unilateral inguinal hernia surgically repaired with similar technique. Mesh was marked with 3 clips. Mesh movements were measured by comparing initial radiography performed at the end of surgery, with a second radiographic scan performed 30 days later. Results: Mean movements of all 3 clips in bilateral nonfixation (NF) group were 0.15–0.4 cm compared with 0.1–0.3 cm in unilateral NF group. Overall displacement of bilateral and unilateral NF groups did not show significant difference. Mean overall displacement was 1.9 cm versus 1.8 cm in the bilateral and unilateral NF groups, respectively (P = .78). Conclusions: TEP with no mesh fixation is safe in bilateral inguinal repairs. Early mesh displacement is minimal. This technique can be safely used in most patients with inguinal hernia. PMID:28904521

  17. Intraoperative Localization of Tantalum Markers for Proton Beam Radiation of Choroidal Melanoma by an Opto-Electronic Navigation System: A Novel Technique

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Amstutz, Christoph A., E-mail: christoph.amstutz@usz.ch; Bechrakis, Nikolaos E.; Foerster, Michael H.

    2012-03-15

    Purpose: External beam proton radiation therapy has been used since 1975 to treat choroidal melanoma. For tumor location determination during proton radiation treatment, surgical tantalum clips are registered with image data. This report introduces the intraoperative application of an opto-electronic navigation system to determine with high precision the position of the tantalum markers and their spatial relationship to the tumor and anatomical landmarks. The application of the technique in the first 4 patients is described. Methods and Materials: A navigated reference base was attached noninvasively to the eye, and a navigated pointer device was used to record the spatial positionmore » of the tantalum markers, the tumor, and anatomical landmarks. Measurement accuracy was assessed on ex vivo porcine eye specimen by repetitive recording of the tantalum marker positions. The method was applied intraoperatively on 4 patients undergoing routine tantalum clip surgery. The spatial position information delivered by the navigation system was compared to the geometric data generated by the EYEPLAN software. Results: In the ex vivo experiments, the maximum repetition error was 0.34 mm. For the intraoperative application, the root mean square error of paired-points matching of the marker positions from the navigation system and from the EYEPLAN software was 0.701-1.25 mm. Conclusions: Navigation systems are a feasible tool for accurate localization of tantalum markers and anatomic landmarks. They can provide additional geometric information, and therefore have the potential to increase the reliability and accuracy of external beam proton radiation therapy for choroidal melanoma.« less

  18. PubMed Central

    Labrecque, M.; Bédard, L.; Laperrière, L.

    1998-01-01

    OBJECTIVE: To compare the efficacy of, and complications associated with, vasectomies performed in two medical clinics. DESIGN: Retrospective cohort study. SETTING: A private medical clinic and a family planning clinic at a teaching hospital in the Quebec City region, where one doctor performs all surgery. PARTICIPANTS: The 1223 men who underwent a first vasectomy between January 1994 and February 1996. INTERVENTIONS: Isolations of the vas deferens through the scrotum was performed using the no-scalpel technique in both clinics. At the private clinic (n = 775), vasectomy was performed by ligature with tantalum clips. At the family planning clinic (n = 448), a combination of cauterisation of the abdominal end of the vas deferens, leaving the testicular end open, and fascial interposition with a clip was used. MAIN OUTCOME MEASURES: Rate of postoperative complications (painful granuloma; noninfectious inflammation of the vas deferens, epididymis, and testes; hematoma; infection; undiagnosed pain) and rate of recanalization (early and late). RESULTS: At the private clinic, 39 patients (5.0%) consulted for postoperative complications, compared with 55 patients (12.3%) at the family planning clinic (chi (2)1 = 21.0; P < 0.001). Of the patients who underwent semen analysis, 15 (2.8%) at the private clinic and 4 (1.2%) at the family planning clinic experienced early or late recanalization (chi (2)1 = 2.2; P < .14). CONCLUSION: The rate of consultation for postoperative complications was lower at the private clinic than at the family planning clinic, but the efficacy of the procedure appeared to be higher at the family planning clinic. The surgical techniques used at the two clinics might partially explain these differences. PMID:9789666

  19. Viewer discretion advised: is YouTube a friend or foe in surgical education?

    PubMed

    Rodriguez, H Alejandro; Young, Monica T; Jackson, Hope T; Oelschlager, Brant K; Wright, Andrew S

    2018-04-01

    In the current era, trainees frequently use unvetted online resources for their own education, including viewing surgical videos on YouTube. While operative videos are an important resource in surgical education, YouTube content is not selected or organized by quality but instead is ranked by popularity and other factors. This creates a potential for videos that feature poor technique or critical safety violations to become the most viewed for a given procedure. A YouTube search for "Laparoscopic cholecystectomy" was performed. Search results were screened to exclude animations and lectures; the top ten operative videos were evaluated. Three reviewers independently analyzed each of the 10 videos. Technical skill was rated using the GOALS score. Establishment of a critical view of safety (CVS) was scored according to CVS "doublet view" score, where a score of ≥5 points (out of 6) is considered satisfactory. Videos were also screened for safety concerns not listed by the previous tools. Median competence score was 8 (±1.76) and difficulty was 2 (±1.8). GOALS score median was 18 (±3.4). Only one video achieved adequate critical view of safety; median CVS score was 2 (range 0-6). Five videos were noted to have other potentially dangerous safety violations, including placing hot ultrasonic shears on the duodenum, non-clipping of the cystic artery, blind dissection in the hepatocystic triangle, and damage to the liver capsule. Top ranked laparoscopic cholecystectomy videos on YouTube show suboptimal technique with half of videos demonstrating concerning maneuvers and only one in ten having an adequate critical view of safety. While observing operative videos can be an important learning tool, surgical educators should be aware of the low quality of popular videos on YouTube. Dissemination of high-quality content on video sharing platforms should be a priority for surgical societies.

  20. Minimizing Retraction by Pia-Arachnoidal 10-0 Sutures in Intrasulcal Dissection.

    PubMed

    Uluc, Kutluay; Cikla, Ulas; Morkan, Deniz B; Sirin, Alperen; Ahmed, Azam S; Swanson, Kyle; Baskaya, Mustafa K

    2018-07-01

    In contemporary microneurosurgery reducing retraction-induced injury to the brain is essential. Self-retaining retractor systems are commonly used to improve visualization and decrease the repetitive microtrauma, but sometimes self-retaining retractor systems can be cumbersome and the force applied can cause focal ischemia or contusions. This may increase the morbidity and mortality. Here, we describe a technique of retraction using 10-0 sutures in the arachnoid. To evaluate the imaging and clinical results in patients where 10-0 suture retraction was used to aid the surgical procedure. Adjacent cortex was retracted by placing 10-0 nylon suture in the arachnoid of the bank or banks of the sulcus. The suture was secured to the adjacent dural edge by using aneurysm clips, allowing for easy adjustability of the amount of retraction. We retrospectively analyzed the neurological outcome, signal changes in postoperative imaging, and ease of performing surgery in 31 patients with various intracranial lesions including intracranial aneurysms, intra- and extra-axial tumors, and cerebral ischemia requiring arterial bypass. Clinically, there were no injuries, vascular events, or neurological deficits referable to the relevant cortex. Postoperative imaging did not show changes consistent with ischemia or contusion due to the retraction. This technique improved the visualization and illumination of the surgical field in all cases. Retraction of the arachnoid can be used safely in cases where trans-sulcal dissection is required. This technique may improve initial visualization and decrease the need for dynamic or static retraction.

  1. From tails to toes: developing nonlethal tissue indicators of mercury exposure in five amphibian species

    USGS Publications Warehouse

    Pfleeger, Adam Z.; Eagles-Smith, Collin A.; Kowalski, Brandon M.; Herring, Garth; Willacker, James J.; Jackson, Allyson K.; Pierce, John

    2016-01-01

    Exposure to environmental contaminants has been implicated as a factor in global amphibian decline. Mercury (Hg) is a particularly widespread contaminant that biomagnifies in amphibians and can cause a suite of deleterious effects. However, monitoring contaminant exposure in amphibian tissues may conflict with conservation goals if lethal take is required. Thus, there is a need to develop non-lethal tissue sampling techniques to quantify contaminant exposure in amphibians. Some minimally invasive sampling techniques, such as toe-clipping, are common in population-genetic research, but it is unclear if these methods can adequately characterize contaminant exposure. We examined the relationships between mercury (Hg) concentrations in non-lethally sampled tissues and paired whole-bodies in five amphibian species. Specifically, we examined the utility of three different tail-clip sections from four salamander species and toe-clips from one anuran species. Both tail and toe-clips accurately predicted whole-body THg concentrations, but the relationships differed among species and the specific tail-clip section or toe that was used. Tail-clips comprised of the distal 0–2 cm segment performed the best across all salamander species, explaining between 82 and 92 % of the variation in paired whole-body THg concentrations. Toe-clips were less effective predictors of frog THg concentrations, but THg concentrations in outer rear toes accounted for up to 79 % of the variability in frog whole-body THg concentrations. These findings suggest non-lethal sampling of tails and toes has potential applications for monitoring contaminant exposure and risk in amphibians, but care must be taken to ensure consistent collection and interpretation of samples.

  2. [MitraClip® for treatment of tricuspid valve insufficiency].

    PubMed

    Pfister, R; Baldus, S

    2017-11-01

    Tricuspid valve regurgitation is frequently found as a result of right ventricular remodeling due to advanced left heart diseases. Drug treatment is limited to diuretics and the cardiac or pulmonary comorbidities. Due to the high risk only a small percentage of patients are amenable to surgical treatment of tricuspid regurgitation in those who undergo left-sided surgery for other reasons. Catheter-based procedures are an attractive treatment alternative, particularly since the strong prognostic impact of tricuspid regurgitation suggests an unmet need of treatment, independent of the underlying heart disease. A vast amount of clinical experience exists for the MitraClip system for treatment of mitral regurgitation. A first case series shows that the application for treatment of tricuspid regurgitation is technically feasible, seems to be safe and the degree of valve regurgitation can be reduced. In this review the background of tricuspid regurgitation treatment is summarized and first experiences and perspectives with the MitraClip system are assessed.

  3. A Comparison of Over-the-Counter Mechanical Nasal Dilators: A Systematic Review.

    PubMed

    Kiyohara, Nicole; Badger, Christopher; Tjoa, Tjoson; Wong, Brian

    2016-09-01

    The internal nasal valve is the narrowest part of the nasal airway and a common site of inspiratory collapse and obstruction of nasal airflow. Over-the-counter mechanical nasal dilators are an alternative to surgical intervention that attempts to improve airflow through the internal nasal valve. To determine the efficacy of over-the-counter mechanical nasal dilators and classify these products by mechanism. A database of 33 available over-the-counter mechanical nasal dilators was generated via a PubMed search as well as an internet search via Amazon.com and Google, conducted from April 1, 2013, through December 31, 2015. Products determined to be unavailable or discontinued were excluded from the database. Of the devices examined in published literature, efficacy was based on objective measures, such as measured airflow, the cross-sectional area of the nasal valve, and changes in resistance. Measures of reported sleep quality or patient perception were excluded. An analysis of each product's mechanism revealed 4 broad classes: external nasal dilator strips, nasal stents, nasal clips, and septal stimulators. A review demonstrated 5 studies supporting the use of external nasal dilator strips, 4 studies supporting the use of nasal clips, 1 study supporting the use of nasal stents, and no studies supporting the use of septal stimulators. Our findings suggest that external nasal dilator strips and nasal clips effectively relieve obstruction of the internal nasal valve and may be an alternative to surgical intervention in some patients.

  4. Tropical Cyclone Report: Joint Typhoon Warning Center Guam, Mariana Islands, 1991

    DTIC Science & Technology

    1991-01-01

    provided by the weather unit supporting synoptic time plus three hours (0300Z, 0900Z, the 15th Air Base Wing , Hickam AFB, Hawaii. 1500Z and 2100Z). By...DYNAMIC 5.2.3.1 CLIMATOLOGY AND PERSISTENCE 5.2.4.1 NOGAPS VORTEX TRACKING ( CLIP ) - A statistical regression technique that ROUTINE (NGPS) - This...forecast skill of other in the expected vicinity of the storm is more sophisticated techniques. CLIP in the conducted every six hours through 72 hours

  5. Reoperation and readmission after clipping of an unruptured intracranial aneurysm: a National Surgical Quality Improvement Program analysis.

    PubMed

    Dasenbrock, Hormuzdiyar H; Smith, Timothy R; Rudy, Robert F; Gormley, William B; Aziz-Sultan, M Ali; Du, Rose

    2018-03-01

    OBJECTIVE Although reoperation and readmission have been used as quality metrics, there are limited data evaluating the rate of, reasons for, and predictors of reoperation and readmission after microsurgical clipping of unruptured aneurysms. METHODS Adult patients who underwent craniotomy for clipping of an unruptured aneurysm electively were extracted from the prospective National Surgical Quality Improvement Program registry (2011-2014). Multivariable logistic regression and recursive partitioning analysis evaluated the independent predictors of nonroutine hospital discharge, unplanned 30-day reoperation, and readmission. Predictors screened included patient age, sex, comorbidities, American Society of Anesthesiologists (ASA) classification, functional status, aneurysm location, preoperative laboratory values, operative time, and postoperative complications. RESULTS Among the 460 patients evaluated, 4.2% underwent any reoperation at a median of 7 days (interquartile range [IQR] 2-17 days) postoperatively, and 1.1% required a cranial reoperation. The most common reoperation was ventricular shunt placement (23.5%); other reoperations were tracheostomy, craniotomy for hematoma evacuation, and decompressive hemicraniectomy. Independent predictors of any unplanned reoperation were age greater than 51 years and longer operative time (p ≤ 0.04). Readmission occurred in 6.3% of patients at a median of 6 days (IQR 5-13 days) after discharge from the surgical hospitalization; 59.1% of patients were readmitted within 1 week and 86.4% within 2 weeks of discharge. The most common reason for readmission was seizure (26.7%); other causes of readmission included hydrocephalus, cerebrovascular accidents, and headache. Unplanned readmission was independently associated with age greater than 65 years, Class II or III obesity (body mass index > 35 kg/m 2 ), preoperative hyponatremia, and preoperative anemia (p ≤ 0.04). Readmission was not associated with operative time, complications during the surgical hospitalization, length of stay, or discharge disposition. Recursive partitioning analysis identified the same 4 variables, as well as ASA classification, as associated with unplanned readmission. The most potent predictors of nonroutine hospital discharge (16.7%) were postoperative neurological and cardiopulmonary complications; other predictors were age greater than 51 years, preoperative hyponatremia, African American and Asian race, and a complex vertebrobasilar circulation aneurysm. CONCLUSIONS In this national analysis, patient age greater than 65 years, Class II or III obesity, preoperative hyponatremia, and anemia were associated with adverse events, highlighting patients who may be at risk for complications after clipping of unruptured cerebral aneurysms. The preponderance of early readmissions highlights the importance of early surveillance and follow-up after discharge; the frequency of readmission for seizure emphasizes the need for additional data evaluating the utility and duration of postcraniotomy seizure prophylaxis. Moreover, readmission was primarily associated with preoperative characteristics rather than metrics of perioperative care, suggesting that readmission may be a suboptimal indicator of the quality of care received during the surgical hospitalization in this patient population.

  6. [Rapid 3-Dimensional Models of Cerebral Aneurysm for Emergency Surgical Clipping].

    PubMed

    Konno, Takehiko; Mashiko, Toshihiro; Oguma, Hirofumi; Kaneko, Naoki; Otani, Keisuke; Watanabe, Eiju

    2016-08-01

    We developed a method for manufacturing solid models of cerebral aneurysms, with a shorter printing time than that involved in conventional methods, using a compact 3D printer with acrylonitrile-butadiene-styrene(ABS)resin. We further investigated the application and utility of this printing system in emergency clipping surgery. A total of 16 patients diagnosed with acute subarachnoid hemorrhage resulting from cerebral aneurysm rupture were enrolled in the present study. Emergency clipping was performed on the day of hospitalization. Digital Imaging and Communication in Medicine(DICOM)data obtained from computed tomography angiography(CTA)scans were edited and converted to stereolithography(STL)file formats, followed by the production of 3D models of the cerebral aneurysm by using the 3D printer. The mean time from hospitalization to the commencement of surgery was 242 min, whereas the mean time required for manufacturing the 3D model was 67 min. The average cost of each 3D model was 194 Japanese Yen. The time required for manufacturing the 3D models shortened to approximately 1 hour with increasing experience of producing 3D models. Favorable impressions for the use of the 3D models in clipping were reported by almost all neurosurgeons included in this study. Although 3D printing is often considered to involve huge costs and long manufacturing time, the method used in the present study requires shorter time and lower costs than conventional methods for manufacturing 3D cerebral aneurysm models, thus making it suitable for use in emergency clipping.

  7. NPS-SCAT (Solar Cell Array Tester), The Construction of NPS’ First Prototype CubeSat

    DTIC Science & Technology

    2008-09-01

    71 Figure 26. Pumpkin Solar Panel Clip Set on the Left and Clips Holding Solar...Panels on the Right......................................................................................................71 Figure 27. Pumpkin ...1998. The satellite provided a global, digital messaging system using spread spectrum techniques in the amateur radio 70 cm band. Most importantly

  8. Evaluation of a Novel Laser-assisted Coronary Anastomotic Connector - the Trinity Clip - in a Porcine Off-pump Bypass Model

    PubMed Central

    Stecher, David; Bronkers, Glenn; Noest, Jappe O.T.; Tulleken, Cornelis A.F.; Hoefer, Imo E.; van Herwerden, Lex A.; Pasterkamp, Gerard; Buijsrogge, Marc P.

    2014-01-01

    To simplify and facilitate beating heart (i.e., off-pump), minimally invasive coronary artery bypass surgery, a new coronary anastomotic connector, the Trinity Clip, is developed based on the excimer laser-assisted nonocclusive anastomosis technique. The Trinity Clip connector enables simplified, sutureless, and nonocclusive connection of the graft to the coronary artery, and an excimer laser catheter laser-punches the opening of the anastomosis. Consequently, owing to the complete nonocclusive anastomosis construction, coronary conditioning (i.e., occluding or shunting) is not necessary, in contrast to the conventional anastomotic technique, hence simplifying the off-pump bypass procedure. Prior to clinical application in coronary artery bypass grafting, the safety and quality of this novel connector will be evaluated in a long-term experimental porcine off-pump coronary artery bypass (OPCAB) study. In this paper, we describe how to evaluate the coronary anastomosis in the porcine OPCAB model using various techniques to assess its quality. Representative results are summarized and visually demonstrated. PMID:25490000

  9. Expert networks in CLIPS

    NASA Technical Reports Server (NTRS)

    Hruska, S. I.; Dalke, A.; Ferguson, J. J.; Lacher, R. C.

    1991-01-01

    Rule-based expert systems may be structurally and functionally mapped onto a special class of neural networks called expert networks. This mapping lends itself to adaptation of connectionist learning strategies for the expert networks. A parsing algorithm to translate C Language Integrated Production System (CLIPS) rules into a network of interconnected assertion and operation nodes has been developed. The translation of CLIPS rules to an expert network and back again is illustrated. Measures of uncertainty similar to those rules in MYCIN-like systems are introduced into the CLIPS system and techniques for combining and hiring nodes in the network based on rule-firing with these certainty factors in the expert system are presented. Several learning algorithms are under study which automate the process of attaching certainty factors to rules.

  10. The Factors Associated with Outcomes in Surgically Managed Ruptured Cerebral Aneurysm.

    PubMed

    Chee, Lai Chuang; Siregar, Johari Adnan; Ghani, Abdul Rahman Izani; Idris, Zamzuri; Rahman Mohd, Noor Azman A

    2018-02-01

    Ruptured cerebral aneurysm is a life-threatening condition that requires urgent medical attention. In Malaysia, a prospective study by the Umum Sarawak Hospital, Neurosurgical Center, in the year 2000-2002 revealed an average of two cases of intracranial aneurysms per month with an operative mortality of 20% and management mortality of 25%. Failure to diagnose, delay in admission to a neurosurgical centre, and lack of facilities could have led to the poor surgical outcome in these patients. The purpose of this study is to identify the factors that significantly predict the outcome of patients undergoing a surgical clipping of ruptured aneurysm in the local population. A single center retrospective study with a review of medical records was performed involving 105 patients, who were surgically treated for ruptured intracranial aneurysms in the Sultanah Aminah Hospital, in Johor Bahru, from July 2011 to January 2016. Information collected was the patient demographic data, Glasgow Coma Scale (GCS) prior to surgery, World Federation of Neurosurgical Societies Scale (WFNS), subarachnoid hemorrhage (SAH) grading system, and timing between SAH ictus and surgery. A good clinical grade was defined as WFNS grade I-III, whereas, WFNS grades IV and V were considered to be poor grades. The outcomes at discharge and six months post surgery were assessed using the modified Rankin's Scale (mRS). The mRS scores of 0 to 2 were grouped into the "favourable" category and mRS scores of 3 to 6 were grouped into the "unfavourable" category. Only cases of proven ruptured aneurysmal SAH involving anterior circulation that underwent surgical clipping were included in the study. The data collected was analysed using the Statistical Package for Social Sciences (SPSS). Univariate and multivariate analyses were performed and a P -value of < 0.05 was considered to be statistically significant. A total of 105 patients were included. The group was comprised of 42.9% male and 57.1% female patients. The mean GCS of the patients subjected to surgical clipping was 13, with the majority falling into the good clinical grade (78.1%). The mean timing of the surgery after SAH was 5.3 days and this was further categorised into early (day one to day three, 45.3%), intermediate (day four to day ten, 56.2%), and late (after day ten, 9.5%). The total favourable outcome achieved at discharge was 59.0% as compared to 41.0% of the unfavourable outcome, with an overall mortality rate of 10.5%. At the six-month post surgery review ( n = 94), the patients with a favourable outcome constituted 71.3% as compared to 28.7% with an unfavourable outcome. The mortality, six months post surgery was 3.2%. On a univariate analysis of early surgical clipping, patients with a better GCS and good clinical grade had a significantly better outcome at discharge. Based on the univariate study, six months post surgery, the timing of the surgery and the clinical grade remained significant predictors of the outcome. On the basis of the multivariate analysis, male patients of younger age, with a good clinical grade, were associated with favourable outcomes, both at discharge and six months post surgery. In this study, we concluded that younger male patients with a good clinical grade were associated with a favourable outcome both at discharge and six months post surgery. We did not find the timing of the surgery, size of the aneurysm or duration of surgery to be associated with a patient's surgical outcome. Increasing age was not associated with the surgical outcome in a longer term of patient's follow up.

  11. E-learning teaches attendings "how to" objectively assess pediatric urology trainees' surgery skills for orchiopexy.

    PubMed

    Fernandez, Nicolas; Maizels, Max; Farhat, Walid; Smith, Edwin; Liu, Dennis; Chua, Michael; Bhanji, Yasin

    2018-04-01

    Established methods to train pediatric urology surgery by residency training programs require updating in response to administrative changes such as new, reduced trainee duty hours. Therefore, new objective methods must be developed to teach trainees. We approached this need by creating e-learning to teach attendings objective assessment of trainee skills using the Zwisch scale, an established assessment tool. The aim of this study was to identify whether or not e-learning is an appropriate platform for effective teaching of this assessment tool, by assessing inter-rater correlation of assessments made by the attendings after participation in the e-learning. Pediatric orchiopexy was used as the index case. An e-learning tool was created to teach attending surgeons objective assessment of trainees' surgical skills. First, e-learning content was created which showed the assessment method videotape of resident surgery done in the operating room. Next, attendings were enrolled to e-learn this method. Finally, the ability of enrollees to assess resident surgery skill performance was tested. Namely, test video was made showing a trainee performing inguinal orchiopexy. All enrollees viewed the same online videos. Assessments of surgical skills (Zwisch scale) were entered into an online survey. Data were analyzed by intercorrelation coefficient kappa analysis (strong correlation was ICC ≥ 0.7). A total of 11 attendings were enrolled. All accessed the online learning and then made assessments of surgical skills trainees showed on videotapes. The e-learning comprised three modules: 1. "Core concepts," in which users learned the assessment tool methods; 2. "Learn to assess," in which users learned how to assess by watching video clips, explaining the assessment method; and 3. "Test," in which users tested their skill at making assessments by watching video clips and then actively inputting their ratings of surgical and global skills as viewed in the video clips (Figure). A total of 89 surgical skill ratings were performed with 56 (65%) exact matches between raters and 89 (100%) matched within one rank. Interclass correlation coefficient (ANOVA) showed statistically significant correlation. (r = 0.725, 95% CI 0.571-0.837, F = 3.976, p ≤ 0.00001). Kappa analysis of inter-rater reliability showed strong consensus between attendings for average measures with ICC = 0.71, 95% CI 0.46-0.95 (p = 0.03). We launched e-learning to teach pediatric urology attendings "how to" assess trainee surgical skills objectively (Zwisch scale). After e-learning, there was strong inter-rater correlation in assessments made. We plan to extend such e-learning to pediatric urology surgical training programs. Copyright © 2017 Journal of Pediatric Urology Company. Published by Elsevier Ltd. All rights reserved.

  12. Multivariable and Bayesian Network Analysis of Outcome Predictors in Acute Aneurysmal Subarachnoid Hemorrhage: Review of a Pure Surgical Series in the Post-International Subarachnoid Aneurysm Trial Era.

    PubMed

    Zador, Zsolt; Huang, Wendy; Sperrin, Matthew; Lawton, Michael T

    2018-06-01

    Following the International Subarachnoid Aneurysm Trial (ISAT), evolving treatment modalities for acute aneurysmal subarachnoid hemorrhage (aSAH) has changed the case mix of patients undergoing urgent surgical clipping. To update our knowledge on outcome predictors by analyzing admission parameters in a pure surgical series using variable importance ranking and machine learning. We reviewed a single surgeon's case series of 226 patients suffering from aSAH treated with urgent surgical clipping. Predictions were made using logistic regression models, and predictive performance was assessed using areas under the receiver operating curve (AUC). We established variable importance ranking using partial Nagelkerke R2 scores. Probabilistic associations between variables were depicted using Bayesian networks, a method of machine learning. Importance ranking showed that World Federation of Neurosurgical Societies (WFNS) grade and age were the most influential outcome prognosticators. Inclusion of only these 2 predictors was sufficient to maintain model performance compared to when all variables were considered (AUC = 0.8222, 95% confidence interval (CI): 0.7646-0.88 vs 0.8218, 95% CI: 0.7616-0.8821, respectively, DeLong's P = .992). Bayesian networks showed that age and WFNS grade were associated with several variables such as laboratory results and cardiorespiratory parameters. Our study is the first to report early outcomes and formal predictor importance ranking following aSAH in a post-ISAT surgical case series. Models showed good predictive power with fewer relevant predictors than in similar size series. Bayesian networks proved to be a powerful tool in visualizing the widespread association of the 2 key predictors with admission variables, explaining their importance and demonstrating the potential for hypothesis generation.

  13. Significantly Elevated C-Reactive Protein Levels After Epicardial Clipping of the Left Atrial Appendage.

    PubMed

    Verberkmoes, Niels J; Akca, Ferdi; Vandevenne, Ann-Sofie; Jacobs, Luuk; Soliman Hamad, Mohamed A; van Straten, Albert H M

    Besides mechanical and anatomical changes of the left atrium, epicardial closure of the left atrial appendage has also possible homeostatic effects. The aim of this study was to assess whether epicardial clipping of the left atrial appendage has different biochemical effects compared with complete removal of the left atrial appendage. Eighty-two patients were included and underwent a totally thoracoscopic AF ablation procedure. As part of the procedure, the left atrial appendage was excluded with an epicardial clip (n = 57) or the left atrial appendage was fully amputated with an endoscopic vascular stapler (n = 25). From all patients' preprocedural and postprocedural blood pressure, electrolytes and inflammatory parameters were collected. The mean age and left atrial volume index were comparable between the epicardial clip and stapler group (64 ± 8 years vs. 60 ± 9 years, P = non-significant; 44 ± 15 mL/m vs. 40 ± 13 mL/m, P = non-significant). Patients receiving left atrial appendage clipping had significantly elevated C-reactive protein levels compared with patients who had left atrial appendage stapling at the second, third, and fourth postoperative day (225 ± 84 mg/L vs. 149 ± 76 mg/L, P = 0.002, 244 ± 78 vs. 167 ± 76, P = 0.004, 190 ± 74 vs. 105 ± 48, P < 0.001, respectively). Patients had a significant decrease in sodium levels, systolic, and diastolic blood pressure at 24 and 72 hours after left atrial appendage closure. However, this was comparable for both the left atrial appendage clipping and stapling group. Increased activation of the inflammatory response was observed after left atrial appendage clipping compared with left atrial appendage stapling. Furthermore, a significant decrease in blood pressure was observed after surgical removal of the left atrial appendage. Whether the inflammatory response affects the outcome of arrhythmia surgery needs to be further evaluated.

  14. In vitro and in vivo biocompatibility study on laser 3D microstructurable polymers

    NASA Astrophysics Data System (ADS)

    Malinauskas, Mangirdas; Baltriukiene, Daiva; Kraniauskas, Antanas; Danilevicius, Paulius; Jarasiene, Rasa; Sirmenis, Raimondas; Zukauskas, Albertas; Balciunas, Evaldas; Purlys, Vytautas; Gadonas, Roaldas; Bukelskiene, Virginija; Sirvydis, Vytautas; Piskarskas, Algis

    2012-09-01

    Films and microstructured scaffolds have been fabricated using direct laser writing out of different polymers: hybrid organic-inorganic ORMOCORE b59, acrylate-based AKRE23, novel organic-inorganic Zr containing hybrid SZ2080, and biodegradable PEG-DA-258. Adult myogenic stem cells were grown on these surfaces in vitro. Their adhesion, growth, and viability test results suggest good potential applicability of the materials in biomedical practice. Pieces of these polymers were implanted in rat's paravertebral back tissue. Histological examination of the implants and surrounding tissue ex vivo after 3 weeks of implantation was conducted and results show the materials to be at least as biocompatible as surgical clips or sutures. The applied direct laser writing technique seems to offer good future prospects in a polymeric 3D scaffold design for artificial tissue engineering with autologous stem cells.

  15. Precautions against cross-infection during operations for maxillofacial trauma.

    PubMed

    Pigadas, N; Avery, C M

    2000-04-01

    One hundred oral and maxillofacial units in the UK were sent a postal questionnaire. Surgical staff of all grades were asked which infection-control measures were taken during the treatment of maxillofacial fractures. Two hundred and ninety-four questionnaires were completed, a response rate of 49%. If the patient was known to be infected by a blood-borne viral disease, significantly more surgeons used standard barrier precautions such as eye protection, fluid-resistant gowns, drapes, ball-ended clips, adhesive tapes and intermediate trays (P<0.0001). Bone-plating techniques were used in preference to wire osteosynthesis (P<0.0001). Only 31 (10.5%) of surgeons routinely used double gloves but 250 (85%) did so if the patient was an infection risk (P<0.0001). Universal precautions were not applied equally to all patients. Copyright 2000.

  16. On clipping of anterior communicating artery aneurysm via eyebrow-lateral keyhole approach

    PubMed Central

    Wang, Hui; Chen, Chuan; Ye, Zhuo-Peng; Luo, Lun; Li, Wen-Sheng; Guo, Ying

    2015-01-01

    Objective: To evaluate the application of eyebrow-lateral keyhole approach in clipping of anterior communicating artery aneurysm (ACAA) through observing the therapeutic effect of eyebrow-lateral keyhole approach on ACAA. Methods: In 37 patients with ACAA, cisterns were exposed via the eyebrow-lateral keyhole approach to reveal ACAA complex followed by clipping of ACAA. Of the 37 patients, external ventricular drainage was performed on 5 patients before microsurgery. All patients underwent head CT angiography on the second day after operation. Results: Clipping of ACAA was successful in all patients at the first time. In 3 patients, ruptured aneurysm occurred during operation. Three patients underwent ventriculoperitoneal shunt because of postoperative hydrocephalus. Two patients had one-sided anterior cerebral artery infarction after operation. No patient died during operation. Follow-up after the operation indicated that 26 patients returned to normal life and work, 6 patients were able to look after themselves, 4 patients required care in their daily life and one patient died. Conclusion: The eyebrow-lateral keyhole approach is a preferred choice for surgical treatment of ACAA because it can cope with brain swelling and intraoperative ruptured aneurysm. However, it has a certain range of application, so we must strictly follow its indications. PMID:26885043

  17. Three-port laparoscopic cholecystectomy by harmonic dissection without cystic duct and artery clipping.

    PubMed

    Tebala, Giovanni D

    2006-05-01

    The technique of laparoscopic cholecystectomy (LC) still has areas of refinements. To decrease the number of ports, a cannula may be replaced by a percutaneous suture suspension of the gallbladder. The risk of tissue injury caused by repeat blind extraction and insertion of various instruments in and out of the abdomen may be decreased by the use of the multipurpose harmonic dissector. One hundred consecutive patients with symptomatic cholelithiasis underwent 3-port LC entirely performed by harmonic dissector without cystic duct and artery clipping. In 8 cases, a fourth trocar was necessary. In 2 cases, the cystic duct was clipped after an unsafe ultrasound sealing. In 1 case, continuous bleeding from the liver required the use of diathermy. No common bile duct injury was registered. The 3-port harmonic LC is a feasible, effective, and safe technique.

  18. A systematic review of discomfort due to toe or ear clipping in laboratory rodents

    PubMed Central

    Geessink, Florentine J.; Brouwer, Michelle A. E.; Tillema, Alice; Ritskes-Hoitinga, Merel

    2017-01-01

    Toe clipping and ear clipping (also ear notching or ear punching) are frequently used methods for individual identification of laboratory rodents. These procedures potentially cause severe discomfort, which can reduce animal welfare and distort experimental results. However, no systematic summary of the evidence on this topic currently exists. We conducted a systematic review of the evidence for discomfort due to toe or ear clipping in rodents. The review methodology was pre-specified in a registered review protocol. The population, intervention, control, outcome (PICO) question was: In rodents, what is the effect of toe clipping or ear clipping, compared with no clipping or sham clipping, on welfare-related outcomes? Through a systematic search in PubMed, Embase, Web of Science and grey literature, we identified seven studies on the effect of ear clipping on animal welfare, and five such studies on toe clipping. Studies were included in the review if they contained original data from an in vivo experiment in rodents, assessing the effect of toe clipping or ear clipping on a welfare-related outcome. Case studies and studies applying unsuitable co-interventions were excluded. Study quality was appraised using an extended version of SYstematic Review Centre for Laboratory animal Experimentation (SYRCLE)’s risk of bias tool for animal studies. Study characteristics and outcome measures were highly heterogeneous, and there was an unclear or high risk of bias in all studies. We therefore present a narrative synthesis of the evidence identified. None of the studies reported a sample size calculation. Out of over 60 different outcomes, we found evidence of discomfort due to ear clipping in the form of increased respiratory volume, vocalization and blood pressure. For toe clipping, increased vocalization and decreased motor activity in pups were found, as well as long-term effects in the form of reduced grip strength and swimming ability in adults. In conclusion, there is too little evidence to reliably assess discomfort due to toe or ear clipping, and the quality of the available evidence is uncertain. Adequately powered, high-quality studies reporting reliable, relevant outcome measures are needed to accurately assess the impact of these identification techniques. Until more reliable evidence is available, any effect of toe clipping or ear clipping on animal welfare and study results cannot be confirmed or excluded. PMID:28429644

  19. Standardized surgical techniques for adult living donor liver transplantation using a modified right lobe graft: a video presentation from bench to reperfusion.

    PubMed

    Hwang, Shin; Ha, Tae-Yong; Ahn, Chul-Soo; Moon, Deok-Bog; Kim, Ki-Hun; Song, Gi-Won; Jung, Dong-Hwan; Park, Gil-Chun; Lee, Sung-Gyu

    2016-08-01

    After having experienced more than 2,000 cases of adult living donor liver transplantation (LDLT), we established the concepts of right liver graft standardization. Right liver graft standardization intends to provide hemodynamics-based and regeneration-compliant reconstruction of vascular inflow and outflow. Right liver graft standardization consists of the following components: Right hepatic vein reconstruction includes a combination of caudal-side deep incision and patch venoplasty of the graft right hepatic vein to remove the acute angle between the graft right hepatic vein and the inferior vena cava; middle hepatic vein reconstruction includes interposition of a uniform-shaped conduit with large-sized homologous or prosthetic grafts; if the inferior right hepatic vein is present, its reconstruction includes funneling and unification venoplasty for multiple short hepatic veins; if donor portal vein anomaly is present, its reconstruction includes conjoined unification venoplasty for two or more portal vein orifices. This video clip that shows the surgical technique from bench to reperfusion was a case presentation of adult LDLT using a modified right liver graft from the patient's son. Our intention behind proposing the concept of right liver graft standardization is that it can be universally applicable and may guarantee nearly the same outcomes regardless of the surgeon's experience. We believe that this reconstruction model would be primarily applied to a majority of adult LDLT cases.

  20. Recovery of Third Nerve Palsy after Endovascular Packing of Internal Carotid-Posterior Communicating Artery Aneurysms

    PubMed Central

    Mavilio, N.; Pisani, R.; Rivano, C.; Testa, V.; Spaziante, R.; Rosa, M.

    2000-01-01

    Summary Endovascular packing of intracranial aneurysm with preservation of the parent vessel has become in many cases a valid alternative to surgical clipping. Regression of oculomotor disorders after clipping of internal carotid-posterior communicating artery (ICA-PCoA) aneurysms has been well assessed. This report focuses on the reversal of third nerve palsy after endovascular packing of ICA-PCoA aneurysms. To this end, clinical appearances, neuroradiological features, and endovascular interventional procedures of six treated patient are reported and discussed in the light of the very few previous case observations found in the literature. Results indicate that endovascular packing of ICA-PCoA aneurysms may produce effective recovery of correlated third nerve dysfunction. PMID:20667199

  1. Sutureless Fixation of Amniotic Membrane for Therapy of Ocular Surface Disorders

    PubMed Central

    Kotomin, Ilya; Valtink, Monika; Hofmann, Kai; Frenzel, Annika; Morawietz, Henning; Werner, Carsten; Funk, Richard H. W.; Engelmann, Katrin

    2015-01-01

    Amniotic membrane is applied to the diseased ocular surface to stimulate wound healing and tissue repair, because it releases supportive growth factors and cytokines. These effects fade within about a week after application, necessitating repeated application. Generally, amniotic membrane is fixed with sutures to the ocular surface, but surgical intervention at the inflamed or diseased site can be detrimental. Therefore, we have developed a system for the mounting of amniotic membrane between two rings for application to a diseased ocular surface without surgical intervention (sutureless amniotic membrane transplantation). With this system, AmnioClip, amniotic membrane can be applied like a large contact lens. First prototypes were tested in an experiment on oneself for wearing comfort. The final system was tested on 7 patients in a pilot study. A possible influence of the ring system on the biological effects of amniotic membrane was analyzed by histochemistry and by analyzing the expression of vascular endothelial growth factor-A (VEGF-A), hepatocyte growth factor (HGF), fibroblast growth factor 2 (FGF 2) and pigment epithelium-derived factor (PEDF) from amniotic membranes before and after therapeutic application. The final product, AmnioClip, showed good tolerance and did not impair the biological effects of amniotic membrane. VEGF-A and PEDF mRNA was expressed in amniotic membrane after storage and mounting before transplantation, but was undetectable after a 7-day application period. Consequently, transplantation of amniotic membranes with AmnioClip provides a sutureless and hence improved therapeutic strategy for corneal surface disorders. Trial Registration ClinicalTrials.gov NCT02168790 PMID:25955359

  2. Indocyanine Green Videoangiography Transoptic Visualization and Clipping Confirmation of an Optic Splitting Ophthalmic Artery Aneurysm.

    PubMed

    Rustemi, Oriela; Cester, Giacomo; Causin, Francesco; Scienza, Renato; Della Puppa, Alessandro

    2016-06-01

    Ophthalmic artery aneurysms with medial and superior projection in exceptionally rare cases can split the optic nerve. Treatment of these aneurysms is challenging, because the aneurysm dome is hidden from the optic nerve, rendering its visualization and clipping confirmation difficult. In addition, optic nerve function should be preserved during surgical maneuvers. Preoperative detection of this growing feature is usually missing. We illustrate the first case of indocyanine green videoangiography (ICG-VA) application in an optic penetrating ophthalmic artery aneurysm treatment. A 57-year-old woman presented with temporal hemianopsia, slight right visual acuity deficit, and new onset of headache. The cerebral angiography detected a right ophthalmic artery aneurysm medially and superiorly projecting. The A1 tract of the ipsilateral anterior cerebral artery was elevated and curved, being suspicious for an under optic aneurysm growth. Surgery was performed. Initially the aneurysm was not visible. ICG-VA permitted the transoptic aneurysm visualization. After optic canal opening, the aneurysm was clipped and transoptic ICG-VA confirmed the aneurysm occlusion. ICG-VA showed also the slight improvement of the optic nerve pial vascularization. Postoperatively, the visual acuity was 10/10 and the hemianopsia did not worsen. The elevation and curve of the A1 tract in medially and superiorly projecting ophthalmic aneurysms may be an indirect sign of under optic growth, or optic splitting aneurysms. ICG-VA transoptic aneurysm detection and occlusion confirmation reduces the surgical maneuvers on the optic nerve, contributing to function preservation. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Reduction of chronic post-herniotomy pain and recurrence rate. Use of the anatomical self-gripping ProGrip laparoscopic mesh in TAPP hernia repair. Preliminary results of a prospective study

    PubMed Central

    Hoskovec, David

    2015-01-01

    Introduction The role of fixation of the mesh is especially important in the endoscopic technique. The fixation of mesh through penetrating techniques using staples, clips or screws is associated with a significantly increased risk of developing a post-herniotomy pain syndrome. Aim To demonstrate the safety and efficacy of the self-fixating anatomical Parietex ProGrip laparoscopic mesh (Sofradim Production, Trévoux France) used with laparoscopic transabdominal preperitoneal hernia repair. The incidence of chronic post-herniotomy pain and recurrence rate in the follow-up after 12 months were evaluated. Material and methods Data analysis included all patients who underwent inguinal hernia surgery at our Surgical Department within the period from 1.05.2013 to 31.12.2014, who fulfilled the inclusion criteria. Standard surgical technique was used. Data were prospectively entered and subsequently analyzed on the Herniamed platform. Herniamed is an internet-based register in German and English language and includes all data of patients who underwent surgery for some types of hernia. Results There were 95 patients enrolled in the group and there were in total 156 inguinal hernias repaired. The mean follow-up was 15.52 months. At the assessment at 1 year mild discomfort in the groin was reported in 2 patients (3.51%) (1–3 VAS). No recurrence or chronic postoperative pain was reported. Conclusions Laparoscopic inguinal hernia repair using the transabdominal preperitoneal technique with implantation of the ProGrip laparoscopic mesh is a fast, effective and reliable method in experienced hands, which according to our results reduces the occurrence of chronic post-operative inguinal pain with simultaneously a low recurrence rate. PMID:26649083

  4. Assessing arsenic and selenium in a single nail clipping using portable X-ray fluorescence.

    PubMed

    Fleming, David E B; Nader, Michel N; Foran, Kelly A; Groskopf, Craig; Reno, Michael C; Ware, Chris S; Tehrani, Mina; Guimarães, Diana; Parsons, Patrick J

    2017-02-01

    The feasibility of measuring arsenic and selenium contents in a single nail clipping was investigated using a small-focus portable X-ray fluorescence (XRF) instrument with monochromatic excitation beams. Nail clipping phantoms supplemented with arsenic and selenium to produce materials with 0, 5, 10, 15, and 20µg/g were used for calibration purposes. In total, 10 different clippings were analyzed at two different measurement positions. Energy spectra were fit with detection peaks for arsenic K α , selenium K α , arsenic K β , selenium K β , and bromine K α characteristic X-rays. Data analysis was performed under two distinct conditions of fitting constraint. Calibration lines were established from the amplitude of each of the arsenic and selenium peaks as a function of the elemental contents in the clippings. The slopes of the four calibration lines were consistent between the two conditions of analysis. The calculated minimum detection limit (MDL) of the method, when considering the K α peak only, ranged from 0.210±0.002µg/g selenium under one condition of analysis to 0.777±0.009µg/g selenium under another. Compared with previous portable XRF nail clipping studies, MDLs were substantially improved for both arsenic and selenium. The new measurement technique had the additional benefits of being short in duration (~3min) and requiring only a single nail clipping. The mass of the individual clipping used did not appear to play a major role in signal strength, but positioning of the clipping is important. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. Preoperative Prediction of the Necessity for Anterior Clinoidectomy During Microsurgical Clipping of Ruptured Posterior Communicating Artery Aneurysms.

    PubMed

    Kamide, Tomoya; Burkhardt, Jan-Karl; Tabani, Halima; Safaee, Michael M; Lawton, Michael T

    2018-01-01

    Although most posterior communicating artery (PCoA) aneurysms can be clipped easily with excellent results, some require anterior clinoidectomy for safe and complete clipping. To review our microsurgical series of ruptured PCoA aneurysms and identify the preoperative predictors for anterior clinoidectomy during microsurgical clipping for PCoA aneurysms. Results from microsurgical clipping of 104 patients with ruptured PCoA aneurysms were reviewed retrospectively. Distances and angles were obtained from computed tomographic angiography and compared between the anterior and nonanterior clinoidectomy groups. Anterior clinoidectomy was required in 19 of the 104 cases (18%). None developed surgical complications due to anterior clinoid process (ACP) resection, including postoperative visual deficit. Univariate and multivariate analyses revealed that the distances from the ACP tip to the aneurysmal proximal neck and from the ACP line to the aneurysmal proximal neck were statistically significant predictive factors for the need of anterior clinoidectomy. Based on a receiver operating characteristic analysis, the distances from the ACP tip to the aneurysmal proximal neck <4.0 mm and from the ACP line to the aneurysmal proximal neck ≤2.0 mm were selected as optimal cutoff values for predicting the necessity of anterior clinoidectomy, and the area under the receiver operating characteristic curve values were 0.991 and 0.955, respectively. In case of ruptured PCoA aneurysm surgery, the distances from the ACP tip to the aneurysmal proximal neck and from the ACP line to the aneurysmal proximal neck were both found to be useful predictors of whether anterior clinoidectomy was required. Copyright © 2017 Elsevier Inc. All rights reserved.

  6. Large Bariatric-Specific Stents and Over-the-Scope Clips in the Management of Post-Bariatric Surgery Leaks.

    PubMed

    Shehab, Hany; Abdallah, Emad; Gawdat, Khaled; Elattar, Inas

    2018-01-01

    Endoscopic stents are successful in the management of surgical leaks; however, stent migration remains a significant problem. In this study, we present our approach depending on a large bariatrics-specific stent (Mega stent) and over-the-scope clips in the management of post-bariatric surgery leaks. A retrospective analysis of all patients with post-bariatric surgery leaks treated at our institution using an approach reliant on Mega stents and over-the-scope clips was conducted. Potential factors associated with procedure success and occurrence of complications were also evaluated. A total of 81 stents were inserted in 62 patients with post-bariatric surgery leaks, 46 sleeve gastrectomies (73%) and 16 Roux-en-Y gastric bypass (27%). Over-the-scope clips were applied in 29 patients (46%). Leak closure was achieved in 51 patients (82%). Median number of procedures per patient was 3 (range 2-8). Complications included the following: stent migration (11/62, 18%), intolerance necessitating premature removal (7/62, 11%), esophageal stricture (8/62, 13%), bleeding (4/62, 6%), perforation (4/62, 6%). One stent-induced mortality was encountered (bleeding). The presence of open surgery (vs laparoscopic) was significantly associated with the occurrence of stent-induced complications (p 0.002). The approach combining Mega stents and over-the-scope clips is highly effective in the management of post-bariatric surgery leaks and is associated with a low rate of stent migration and a low number of procedures and stents per patient. Mega stents, however, should be used with great caution due to the significant morbidity associated with their use.

  7. Simultaneous bilateral robotic partial nephrectomy: Case report and critical evaluation of the technique.

    PubMed

    Giberti, Claudio; Gallo, Fabrizio; Schenone, Maurizio; Cortese, Pierluigi

    2014-06-16

    We report our first simultaneous bilateral robot assisted partial nephrectomy (RAPN) in order to show and critically discuss the feasibility of this procedure. Materials and methods A 69-year-old male patient visited our department due to incidental finding of bilateral mesorenal small masses (2.5 cm on the right and 3.5 cm on the left) suspicious for malignancy. We started from the right side with patient in flank position. Port placement: 12-mm periumbilical camera port, two 8-mm robotic ports in wide ''V''configuration, additional 12 mm assistant port on the midline between the umbilicus and symphysis pubis. A right unclamping RAPN with sliding clip renorrhaphy was performed. The trocars were removed and the robot undocked. Without interrupting the anesthesiological procedures, the patient was reported in supine position and, after 180 degrees rotation of the surgical bed, was newly placed in contralateral flank position. Using both the previous periumbilical and midline ports, two other 8-mm robotic trocars were placed. The robot was then redocked and RAPN was also performed on the left side using the same previously reported technique. Results Total time: 285 min. Estimated blood losses: 150 cc. Postoperative period: uneventful. Pathological examination: bilateral renal cell carcinoma, negative surgical margins. Conclusions Our experience was encouraging and confirmed the feasibility and safety of this procedure. The planning of our technique was time and cost effective with cosmetic benefit for the patient. However, we think that an appropriate selection of the patients and a skill in robotic renal surgery are advisable before approaching this type of surgery.

  8. Microneurosurgical Management of Posterior Communicating Artery Aneurysm: A Contemporary Series from Helsinki.

    PubMed

    Thiarawat, Peeraphong; Jahromi, Behnam Rezai; Kozyrev, Danil A; Intarakhao, Patcharin; Teo, Mario K; Choque-Velasquez, Joham; Hernesniemi, Juha

    2017-05-01

    The objectives of this study were to analyze microsurgical techniques and to determine correlations between microsurgical techniques and the radiographic findings in the microneurosurgical treatment of posterior communicating artery aneurysms (PCoAAs). We retrospectively analyzed radiographic findings and videos of surgeries in 64 patients with PCoAAs who underwent microsurgical clipping by the senior author from August 2010 to 2014. From 64 aneurysms, 30 (47%) had acute subarachnoid hemorrhage (SAH) that necessitated lamina terminalis fenestration (odds ratio [OR], 67.67; P < 0.001) and Liliequist membrane fenestration (OR, 19.62; P < 0.001). The low-lying aneurysms significantly necessitated the coagulation of the dura covering the anterior clinoid process (ACP) (OR, 7.43; P = 0.003) or anterior clinoidectomy (OR, 91.0; P < 0.001). We preferred straight clips in 45 (83%) of 54 posterolateral projecting aneurysms (OR, 45.0; P < 0.001), but preferred curved clips for posteromedial projecting aneurysms (OR, 6.39; P = 0.008). The mean operative time from the brain retraction to the final clipping was 17 minutes and 43 seconds. Postoperative computed tomography angiography revealed complete occlusion of 60 (94%) aneurysms. Three (4.6%) patients with acute SAH suffered postoperative lacunar infarction. For ruptured aneurysms, lamina terminalis and Liliequist membrane fenestration are useful for additional cerebrospinal fluid drainage. For low-lying aneurysms, coagulation of the dura covering the ACP or tailored anterior clinoidectomy might be necessary for exposing the proximal aneurysm neck. Type of clips depends on the direction of projection. The microsurgical clipping of the PCoAAs can achieve good immediate complete occlusion rate with low postoperative stroke rate. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Dual-Image Videoangiography During Intracranial Microvascular Surgery.

    PubMed

    Feletti, Alberto; Wang, Xiangdong; Tanaka, Riki; Yamada, Yasuhiro; Suyama, Daisuke; Kawase, Tsukasa; Sano, Hirotoshi; Kato, Yoko

    2017-03-01

    Indocyanine green videoangiography (ICG-VA) is a valuable tool to assess vessel and aneurysm patency during neurovascular surgical procedures. However, ICG-VA highlights vascular structures, which appear white over a black background. Anatomic relationships are sometimes difficult to understand at first glance. Dual-image videoangiography (DIVA) enables simultaneous visualization of light and near-infrared fluorescence images of ICG-VA. The DIVA system was mounted on an OPMI Pentero Flow 800 intraoperative microscope. DIVA was used during microsurgical procedures on 5 patients who were operated for aneurysm clipping and superficial temporal artery-middle cerebral artery bypass. DIVA provides real-time simultaneous visualization of aneurysm and vessels and surrounding structures including brain, nerves, and surgical clips. Although visual contrast between vessels and background is higher with standard black-and-white imaging, DIVA makes it easier to understand anatomic relationships between intracranial structures. DIVA also provides better vision of the depth of field. DIVA has the potential to become a widely used intraoperative tool to check patency of intracranial vessels. It should be considered as an adjunct to standard ICG-VA for better understanding of vascular anatomy in relation to surrounding structures and can have an impact on decision making during surgery. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. Robotic digital subtraction angiography systems within the hybrid operating room.

    PubMed

    Murayama, Yuichi; Irie, Koreaki; Saguchi, Takayuki; Ishibashi, Toshihiro; Ebara, Masaki; Nagashima, Hiroyasu; Isoshima, Akira; Arakawa, Hideki; Takao, Hiroyuki; Ohashi, Hiroki; Joki, Tatsuhiro; Kato, Masataka; Tani, Satoshi; Ikeuchi, Satoshi; Abe, Toshiaki

    2011-05-01

    Fully equipped high-end digital subtraction angiography (DSA) within the operating room (OR) environment has emerged as a new trend in the fields of neurosurgery and vascular surgery. To describe initial clinical experience with a robotic DSA system in the hybrid OR. A newly designed robotic DSA system (Artis zeego; Siemens AG, Forchheim, Germany) was installed in the hybrid OR. The system consists of a multiaxis robotic C arm and surgical OR table. In addition to conventional neuroendovascular procedures, the system was used as an intraoperative imaging tool for various neurosurgical procedures such as aneurysm clipping and spine instrumentation. Five hundred one neurosurgical procedures were successfully conducted in the hybrid OR with the robotic DSA. During surgical procedures such as aneurysm clipping and arteriovenous fistula treatment, intraoperative 2-/3-dimensional angiography and C-arm-based computed tomographic images (DynaCT) were easily performed without moving the OR table. Newly developed virtual navigation software (syngo iGuide; Siemens AG) can be used in frameless navigation and in access to deep-seated intracranial lesions or needle placement. This newly developed robotic DSA system provides safe and precise treatment in the fields of endovascular treatment and neurosurgery.

  11. Augmented reality in the surgery of cerebral aneurysms: a technical report.

    PubMed

    Cabrilo, Ivan; Bijlenga, Philippe; Schaller, Karl

    2014-06-01

    Augmented reality is the overlay of computer-generated images on real-world structures. It has previously been used for image guidance during surgical procedures, but it has never been used in the surgery of cerebral aneurysms. To report our experience of cerebral aneurysm surgery aided by augmented reality. Twenty-eight patients with 39 unruptured aneurysms were operated on in a prospective manner with augmented reality. Preoperative 3-dimensional image data sets (angio-magnetic resonance imaging, angio-computed tomography, and 3-dimensional digital subtraction angiography) were used to create virtual segmentations of patients' vessels, aneurysms, aneurysm necks, skulls, and heads. These images were injected intraoperatively into the eyepiece of the operating microscope. An example case of an unruptured posterior communicating artery aneurysm clipping is illustrated in a video. The described operating procedure allowed continuous monitoring of the accuracy of patient registration with neuronavigation data and assisted in the performance of tailored surgical approaches and optimal clipping with minimized exposition. Augmented reality may add to the performance of a minimally invasive approach, although further studies need to be performed to evaluate whether certain groups of aneurysms are more likely to benefit from it. Further technological development is required to improve its user friendliness.

  12. An alternate and reversible method for flight restraint of cranes.

    PubMed

    Zhang, Sen Lin; Yang, Shu Hui; Li, Bing; Xu, Yan Chun; Ma, Jian Hua; Xu, Jian Feng; Zhang, Xian Guang

    2011-01-01

    Flight restraint is important for zoos, safaris, and breeding centers for large birds. Currently used techniques for flight restraint include both surgical and non-surgical approaches. Surgical approaches usually cause permanent change to or removal of tendon, patagial membrane, or wing bones, and can cause pain and inflammation. Non-surgical approaches such as clipping or trimming feathers often alter the bird's appearance, and can damage growing blood feathers in fledglings or cause joint stiffness. We observed microstructure of primary feathers of the red-crowned crane (Grus japonensis) and found that the width of barbs is a determinative factor influencing vane stiffness and geometric parameters. We hypothesized that partial longitudinal excision of barbs on the ventral surface of the primary feathers would reduce the stiffness of the vane and render the feathers unable to support the crane's body weight during flight. Furthermore, we hypothesized that this modification of barbs would also change the aerodynamic performance of feathers such that they could not generate sufficient lift and thrust during flapping to enable the bird to fly. We tested this hypothesis on a red-crowned crane that had normal flight capability by excising the ventral margin of barbs on all 10 primaries on the left wing. The bird was unable to take off until the modified feathers were replaced by new ones. Removal of barbs proved to be a simple, non-invasive, low-cost and reversible method for flight restraint. It is potentially applicable to other large birds with similar structural characteristics of primary feathers. © 2010 Wiley-Liss, Inc.

  13. Audiological comparison between two different clips prostheses in stapes surgery.

    PubMed

    Potena, M; Portmann, D; Guindi, S

    2015-01-01

    To compare audiometric results and complications of stapes surgery with two different types of piston prosthesis, the Portmann Clip Piston (Medtronic) (PCP) and the Soft Clip Piston (Kurz) (SCP). Study conducted on 64 patients who underwent primary stapedotomy from 2008 to 2011. We matched for each case of stapedotomy with the PCP (Medtronic Xomed Inc. Portmann Clip Piston Stainless Steel/Fluoroplastic) a case with the SCP (Heinz Kurz GmbH Medizintechnik Soft Piston Clip Titanium). Each group consisted of 32 patients, and patients in both groups were matched with respect to gender, age, bilateral or unilateral otosclerosis, otological symptoms (tinnitus, vertigo or dizziness), family history, operated side and the Portmann grading for otosclerosis. The length of the prosthesis used was reported. Post-operative complications such as tinnitus, vertigo, hearing loss and altered taste were documented. Each patient was subjected to a preoperative and postoperative audiogram (follow-up at the second month after the surgery). We used the Student test for statistical analysis. Statistical significance was set at < 0.01. None of the patients experienced a post-operative hearing loss and none required a later revision surgery. No statistically significant difference was found between the two populations regarding demographic data (age, sex, side, bilaterality, family history, stage and lenght of piston) and hearing level (> 0.01) in the air, bone conduction and air-bone gap (ABG). Postoperative complications did not result to be significantly different between the two groups. Also, both groups showed a significant improvement (< 0.01) in the post-operative air, bone conduction and air-bone gap. There was no statistically significant difference (> 0.01) between the post-operative hearing results (bone conduction, air conduction, air-bone gap) using the two pistons. The mean ABG improvement was respectively 16.63 dB in the SCP group and 20.59 dB in the PCP group. The titanium Soft clip piston (SCP) is a good alternative to the Portmann clip piston (PCP). Nevertheless there are some differences in the surgical fixing of these two pistons in the correct position.

  14. Mitral Valve Clip for Treatment of Mitral Regurgitation: An Evidence-Based Analysis

    PubMed Central

    Ansari, Mohammed T.; Ahmadzai, Nadera; Coyle, Kathryn; Coyle, Doug; Moher, David

    2015-01-01

    Background Many of the 500,000 North American patients with chronic mitral regurgitation may be poor candidates for mitral valve surgery. Objective The objective of this study was to investigate the comparative effectiveness, harms, and cost-effectiveness of percutaneous mitral valve repair using mitral valve clips in candidates at prohibitive risk for surgery. Data Sources We searched articles in MEDLINE, Embase, and the Cochrane Library published from 1994 to February 2014 for evidence of effectiveness and harms; for economic literature we also searched NHS EED and Tufts CEA registry. Grey literature was also searched. Review Methods Primary studies were sought from existing systematic reviews that had employed reliable search and screening methods. Newer studies were sought by searching the period subsequent to the last search date of the review. Two reviewers screened records and assessed study validity. We used the Cochrane risk of bias tool for randomized, generic assessment for non-randomized studies, and the Phillips checklist for economic studies. Results Ten studies including 1 randomized trial were included. The majority of the direct comparative evidence compared the mitral valve clip repair with surgery in patients not particularly at prohibitive surgical risk. Irrespective of degenerative or functional chronic mitral regurgitation etiology, evidence of effectiveness and harms is inconclusive and of very low quality. Very-low-quality evidence indicates that percutaneous mitral valve clip repair may provide a survival advantage, at least during the first 1 to 2 years, particularly in medically managed chronic functional mitral regurgitation. Because of limitations in the design of studies, the cost-effectiveness of mitral valve clips in patients at prohibitive risk for surgery also could not be established. Limitations Because of serious concerns of risk of bias, indirectness, and imprecision, evidence is of very low quality. Conclusions No meaningful conclusions can be drawn about the comparative effectiveness, harms, and cost-effectiveness of mitral valve clips in the population with chronic mitral regurgitation who are at prohibitive risk for surgery. PMID:26379810

  15. Patient Satisfaction after Thoracoscopic Sympathectomy for Palmar Hyperhidrosis: Do Method and Level Matter?

    PubMed Central

    Cheng, Amy; Johnsen, Hege; Chang, Michael Y

    2015-01-01

    Context: Although surgery is widely recognized as the best treatment for palmar hyperhidrosis (PH), the decision to perform a sympathicotomy, sympathectomy, or clipping of the thoracic sympathetic chain is based on surgeon preference. Objective: We investigated the outcomes of patients who underwent surgical intervention for PH with regard to method used and level of sympathetic chain interrupted. Design: This was a retrospective medical chart review. Patients who underwent thoracoscopic intervention for PH were mailed questionnaires regarding their presenting and postoperative symptoms and satisfaction 6 months to 15 years after their procedure. Analyses were performed to investigate whether the surgical method applied affected these outcomes. Results: A total of 635 patients underwent bilateral thoracoscopic procedures for PH between April 1995 and February 2010, and 210 (33%) responded to the questionnaires. Sixteen surgeons performed 108 sympathicotomies, 83 sympathectomies, and 19 ligations with titanium clips for PH. Mean follow-up was 5.5 years. Overall palmar success was 85.4% and was not affected by the surgical method. The rate of compensatory hyperhidrosis was significantly lower if the operative level did not include the R2 ganglion (66.7% vs 80.6%, p = 0.028). Nevertheless, 76.2% of patients were satisfied with the results, and 85.7% would repeat the procedure if given the option to do it again. Conclusion: Most patients reported relief of their PH and were satisfied with surgical intervention, regardless of method used. Although postoperative compensatory hyperhidrosis was common, this did not appear to affect overall patient satisfaction. The inclusion of rib level 2 ganglion resulted in a significantly increased incidence of compensatory hyperhidrosis. PMID:26517433

  16. Nasojejunal-stent technique (NJST): A new system to prevent fully covered metal stent migration in the treatment of benign esophageal diseases.

    PubMed

    Hernández Mondragón, Oscar Víctor; Cuellar, Raquel Palos; Murcio Pérez, Enrique

    2018-05-19

    Fully covered self-expandable metal stents (FCSEMS) have been used for the treatment of benign esophageal conditions such as perforation, leaks, and strictures [1]; high clinical success is reported [2]. Different anchoring methods have been described (clips, suturing devices, over-the-scope clips and Shim technique [2]), because of high migration rates (4-36%) [3,4]. However, not all cases are candidates, mostly in "difficult" cases where enteral feeding is needed [5]. We report the use of the nasojejunal-stent technique (NJST) to prevent migration of FCSEMS in three difficult cases. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  17. Patient selection, echocardiographic screening and treatment strategies for interventional tricuspid repair using the edge-to-edge repair technique.

    PubMed

    Hausleiter, Jörg; Braun, Daniel; Orban, Mathias; Latib, Azeem; Lurz, Philipp; Boekstegers, Peter; von Bardeleben, Ralph Stephan; Kowalski, Marek; Hahn, Rebecca T; Maisano, Francesco; Hagl, Christian; Massberg, Steffen; Nabauer, Michael

    2018-04-24

    Severe tricuspid regurgitation (TR) has long been neglected despite its well known association with mortality. While surgical mortality rates remain high in isolated tricuspid valve surgery, interventional TR repair is rapidly evolving as an alternative to cardiac surgery in selected patients at high surgical risk. Currently, interventional edge-to-edge repair is the most frequently applied technique for TR repair even though the device has not been developed for this particular indication. Due to the inherent differences in tricuspid and mitral valve anatomy and pathology, percutaneous repair of the tricuspid valve is challenging due to a variety of factors including the complexity and variability of tricuspid valve anatomy, echocardiographic visibility of the valve leaflets, and device steering to the tricuspid valve. Furthermore, it remains to be clarified which patients are suitable for a percutaneous tricuspid repair and which features predict a successful procedure. On the basis of the available experience, we describe criteria for patient selection including morphological valve features, a standardized process for echocardiographic screening, and a strategy for clip placement. These criteria will help to achieve standardization of valve assessment and the procedural approach, and to further develop interventional tricuspid valve repair using either currently available devices or dedicated tricuspid edge-to-edge repair devices in the future. In summary, this manuscript will provide guidance for patient selection and echocardiographic screening when considering edge-to-edge repair for severe TR.

  18. High-intensity focused ultrasound (HIFU)-assisted hepatic resection in an animal model.

    PubMed

    Gandini, Alessandro; Melodelima, David; Schenone, Francesco; N'Djin, Apoutou William; Chapelon, Jean Yves; Rivoire, Michel

    2012-07-01

    Bleeding is the main cause of postoperative complications of hepatic surgery. To minimize intraoperative bleeding during hepatectomy, resections are generally carried out under hepatic vascular control despite the risk of liver dysfunction in patients with chronic liver disease. This study evaluates the feasibility and safety of high-intensity focused ultrasound (HIFU)-assisted hepatic resection during an open procedure in an animal model. Three groups of 12-14-week-old Landrace pigs (n = 7/group) were used to evaluate HIFU-assisted liver resection (group A) vs liver resection with or without portal triad clamping (groups B and C). In each pig, liver resection was performed on the right and left paramedian lobes. The following were evaluated and compared in the 3 groups: total blood loss, blood loss/cm(2) of resection area, clip density, procedure duration, morbidity, and mortality. Median blood loss was significantly lower in group A than in group B (P = .02), and group C (P = .007). Median blood loss/cm(2) of resection area was 4.77 mL/cm² in group A, 11.35 mL/cm² in group B, 12.22 mL/cm² in Group C. Precoagulation resulted in sealing blood vessels <5 mm; therefore, median clip density during liver transection was 0.78 clip/cm² in group A, 1.61 clip/cm(2) in group B, and 1.57 clip/cm(2) in group C. Median duration of the surgical procedure was 12 min in group A, 21 min in group B, and 19 min in group C. HIFU-assisted hepatic resection during an open procedure in an animal model is safe, reduces bleeding, and allows real-time ultrasound guidance.

  19. Speed Biases With Real-Life Video Clips

    PubMed Central

    Rossi, Federica; Montanaro, Elisa; de’Sperati, Claudio

    2018-01-01

    We live almost literally immersed in an artificial visual world, especially motion pictures. In this exploratory study, we asked whether the best speed for reproducing a video is its original, shooting speed. By using adjustment and double staircase methods, we examined speed biases in viewing real-life video clips in three experiments, and assessed their robustness by manipulating visual and auditory factors. With the tested stimuli (short clips of human motion, mixed human-physical motion, physical motion and ego-motion), speed underestimation was the rule rather than the exception, although it depended largely on clip content, ranging on average from 2% (ego-motion) to 32% (physical motion). Manipulating display size or adding arbitrary soundtracks did not modify these speed biases. Estimated speed was not correlated with estimated duration of these same video clips. These results indicate that the sense of speed for real-life video clips can be systematically biased, independently of the impression of elapsed time. Measuring subjective visual tempo may integrate traditional methods that assess time perception: speed biases may be exploited to develop a simple, objective test of reality flow, to be used for example in clinical and developmental contexts. From the perspective of video media, measuring speed biases may help to optimize video reproduction speed and validate “natural” video compression techniques based on sub-threshold temporal squeezing. PMID:29615875

  20. Speed Biases With Real-Life Video Clips.

    PubMed

    Rossi, Federica; Montanaro, Elisa; de'Sperati, Claudio

    2018-01-01

    We live almost literally immersed in an artificial visual world, especially motion pictures. In this exploratory study, we asked whether the best speed for reproducing a video is its original, shooting speed. By using adjustment and double staircase methods, we examined speed biases in viewing real-life video clips in three experiments, and assessed their robustness by manipulating visual and auditory factors. With the tested stimuli (short clips of human motion, mixed human-physical motion, physical motion and ego-motion), speed underestimation was the rule rather than the exception, although it depended largely on clip content, ranging on average from 2% (ego-motion) to 32% (physical motion). Manipulating display size or adding arbitrary soundtracks did not modify these speed biases. Estimated speed was not correlated with estimated duration of these same video clips. These results indicate that the sense of speed for real-life video clips can be systematically biased, independently of the impression of elapsed time. Measuring subjective visual tempo may integrate traditional methods that assess time perception: speed biases may be exploited to develop a simple, objective test of reality flow, to be used for example in clinical and developmental contexts. From the perspective of video media, measuring speed biases may help to optimize video reproduction speed and validate "natural" video compression techniques based on sub-threshold temporal squeezing.

  1. A1297 GPR vs. hydro video clip.

    DOT National Transportation Integrated Search

    2014-03-01

    This research has examined the use of nondestructive techniques for concrete bridge deck condition assessments. The primary nondestructive testing/evaluation (NDT/NDE) technique utilized in this research was ground-coupled ground penetrating radar (G...

  2. Virtual tape measure for the operating microscope: system specifications and performance evaluation.

    PubMed

    Kim, M Y; Drake, J M; Milgram, P

    2000-01-01

    The Virtual Tape Measure for the Operating Microscope (VTMOM) was created to assist surgeons in making accurate 3D measurements of anatomical structures seen in the surgical field under the operating microscope. The VTMOM employs augmented reality techniques by combining stereoscopic video images with stereoscopic computer graphics, and functions by relying on an operator's ability to align a 3D graphic pointer, which serves as the end-point of the virtual tape measure, with designated locations on the anatomical structure being measured. The VTMOM was evaluated for its baseline and application performances as well as its application efficacy. Baseline performance was determined by measuring the mean error (bias) and standard deviation of error (imprecision) in measurements of non-anatomical objects. Application performance was determined by comparing the error in measuring the dimensions of aneurysm models with and without the VTMOM. Application efficacy was determined by comparing the error in selecting the appropriate aneurysm clip size with and without the VTMOM. Baseline performance indicated a bias of 0.3 mm and an imprecision of 0.6 mm. Application bias was 3.8 mm and imprecision was 2.8 mm for aneurysm diameter. The VTMOM did not improve aneurysm clip size selection accuracy. The VTMOM is a potentially accurate tool for use under the operating microscope. However, its performance when measuring anatomical objects is highly dependent on complex visual features of the object surfaces. Copyright 2000 Wiley-Liss, Inc.

  3. A toroidial-shaped HIFU transducer for assisting hepatic resection: a complementary tool for surgery

    NASA Astrophysics Data System (ADS)

    N'Djin, W. A.; Melodelima, D.; Schenone, F.; Rivoire, M.; Chapelon, J. Y.

    2009-04-01

    A toroidial-shaped HIFU medical device with integrated ultrasound imaging was developed for the treatment of colorectal liver metastasis. The HIFU toroidïal-shaped transducer contained 256-elements (working frequency: 3 MHz) and allows creating a single conical lesion of 7 cm3 in 40 seconds (Ifocal = 1700 W.cm-2). Volumes of treatment can then be significantly increase by juxtaposing single lesions. Presented here is the use of this device in an animal model as a complementary tool to improve surgical resection in the liver. A zone of coagulative necrosis before transecting the liver was performed using this device in order to minimize blood loss and dissection time during hepatectomy. Resection assisted by HIFU (RA-HIFU) was compared with classical dissections with clamping (RC) and without clamping (Control). For each technique 14 partial liver resections were performed in seven pigs. Blood loss per dissection surface area was the main outcome parameter. Blood loss during liver transection was significantly lower in RA-HIFU (7.4±3.3 ml.cm-2) than in RC (34%) and Control (47%). The duration of transection in RA-HIFU (13±3 min) was significantly shorter than in RC (44%) and Control (28%). Precoagulation also resulted in the use of significantly fewer clips; the number of clips used per square centimetre was 50% lower in RA-HIFU (0.8±0.2 cm-2) than in the other groups.

  4. Single-Step Fabrication of Computationally Designed Microneedles by Continuous Liquid Interface Production

    PubMed Central

    Johnson, Ashley R.; Caudill, Cassie L.; Tumbleston, John R.; Bloomquist, Cameron J.; Moga, Katherine A.; Ermoshkin, Alexander; Shirvanyants, David; Mecham, Sue J.; Luft, J. Christopher; DeSimone, Joseph M.

    2016-01-01

    Microneedles, arrays of micron-sized needles that painlessly puncture the skin, enable transdermal delivery of medications that are difficult to deliver using more traditional routes. Many important design parameters, such as microneedle size, shape, spacing, and composition, are known to influence efficacy, but are notoriously difficult to alter due to the complex nature of microfabrication techniques. Herein, we utilize a novel additive manufacturing (“3D printing”) technique called Continuous Liquid Interface Production (CLIP) to rapidly prototype sharp microneedles with tuneable geometries (size, shape, aspect ratio, spacing). This technology allows for mold-independent, one-step manufacturing of microneedle arrays of virtually any design in less than 10 minutes per patch. Square pyramidal CLIP microneedles composed of trimethylolpropane triacrylate, polyacrylic acid and photopolymerizable derivatives of polyethylene glycol and polycaprolactone were fabricated to demonstrate the range of materials that can be utilized within this platform for encapsulating and controlling the release of therapeutics. These CLIP microneedles effectively pierced murine skin ex vivo and released the fluorescent drug surrogate rhodamine. PMID:27607247

  5. Secured independent tools in peritoneoscopy.

    PubMed

    Tsin, Daniel A; Davila, Fausto; Dominguez, Guillermo; Manolas, Panagiotis

    2010-01-01

    Secured independent tools are being introduced to aid in peritoneoscopy. We present a simple technique for anchoring instruments, powered lights, and micro machines through the abdominal wall. We used a laparoscopic trainer, micro alligator clips with one or two 2-0 nylon tails and cables for engines and lights. The above instruments were introduced via a 12-mm or 15-mm port. Clips were placed for traction, retraction and exposure, lights for illumination, and motors for potential work. A laparoscopy port closure or suture passer was introduced percutaneously to grab and extract the tails or cables outside of the simulated abdominal cavity. The engines and lights were powered by a direct electric current (DC) plugged into exteriorized cables. We used 2 to 3 clips for each, and engines performed well. This basic simulation adds independent instruments, lights, and engines. We replaced cannulas with threads or cables in an attempt to limit the number of ports. This technique further opens the door for innovations in wired machines in laparoscopy, single-port laparoscopy, or natural orifice surgery.

  6. [Virtual surgical education: experience with medicine and surgery students].

    PubMed

    Bonavina, Luigi; Mozzi, Enrico; Peracchia, Alberto

    2003-01-01

    The use of virtual reality simulation is currently being proposed within programs of postgraduate surgical education. The simple tasks that make up an operative procedure can be repeatedly performed until satisfactory execution is achieved, and the errors can be corrected by means of objective assessment. The aim of this study was to evaluate the applicability and the results of structured practice with the LapSim laparoscopic simulator used by undergraduate medical students. A significant reduction in operative time and errors was noted in several tasks (navigation, clipping, etc.). Although the transfer of technical skills to the operating room environment remains to be demonstrated, our research shows that this type of teaching is applicable to undergraduate medical students and in future may become a useful tool for selecting individuals for surgical residency programs.

  7. The Clinical Importance of Perforator Preservation in Intracranial Aneurysm Surgery: An Overview with a Review of the Literature.

    PubMed

    Joo, Sung-Pil; Kim, Tae-Sun

    2017-01-01

    Clipping for intracranial aneurysms is done to achieve complete occlusion of the aneurysm without a remnant sac. Despite modern advancements of neurosurgical techniques, morbidity related to the clipping of intracranial aneurysms still exists. Clip occlusion of a parent artery or small hidden perforators commonly leads to permanent neurological deficits, and is a serious and unwanted complication. Thus, preserving blood flow in the branches and perforators of a parent artery is very important for successful surgery without postoperative morbidity and mortality. The aim of this review article is to discuss the consequences of perforator injury and how to avoid this phenomenon in aneurysm surgeries using intraoperative monitoring devices.

  8. Effects of eradication and restoration treatments on Italian thistle (Carduus pycnocephalus)

    USGS Publications Warehouse

    McGinnis, Thomas; Keeley, Jon

    2011-01-01

    Low elevation grasslands in California long have been dominated by Mediterranean grasses, but many areas still have large native forb populations. Alien forbs invade these grasslands, displacing both native and other alien species. Italian thistle is a noxious alien herb that has recently invaded these grasslands, including ungrazed blue oak (Quercus douglassii) and interior live oak (Quercus wislizenii) stands in Sequoia National Park. Here, Italian thistle tends to dominate under oaks and has the potential to substantially alter the foothill ecosystem by displacing native plants and acting as a ladder fuel that can carry fires into the oak canopy. We tested the effects of selectively reducing Italian thistle populations alone and in combination with restoration of native species. Two thistle eradication techniques (clipping and the application of clopyralid herbicide) and two restoration techniques (addition of native forb seeds or planting native grass plugs) were used. After two consecutive years of treatment we found: a) clipping was not effective at reducing Italian thistle populations (clipping reduced Italian thistle density in some areas, but not vegetative cover), b) herbicide reduced both Italian thistle density and vegetative cover for the first two growing seasons after application, but cover rebounded in the third growing season, c) native forb cover and species richness were not significantly affected by clipping or spot-treating with herbicide, d) the grass and forb addition treatments by themselves were not effective at reducing Italian thistle during the course of this study and e) sowing annual forb seeds after clipping resulted in greater forb cover and moderately reduced Italian thistle vegetative cover in the short term.

  9. Splitting a colon geometry with multiplanar clipping

    NASA Astrophysics Data System (ADS)

    Ahn, David K.; Vining, David J.; Ge, Yaorong; Stelts, David R.

    1998-06-01

    Virtual colonoscopy, a recent three-dimensional (3D) visualization technique, has provided radiologists with a unique diagnostic tool. Using this technique, a radiologist can examine the internal morphology of a patient's colon by navigating through a surface-rendered model that is constructed from helical computed tomography image data. Virtual colonoscopy can be used to detect early forms of colon cancer in a way that is less invasive and expensive compared to conventional endoscopy. However, the common approach of 'flying' through the colon lumen to visually search for polyps is tedious and time-consuming, especially when a radiologist loses his or her orientation within the colon. Furthermore, a radiologist's field of view is often limited by the 3D camera position located inside the colon lumen. We have developed a new technique, called multi-planar geometry clipping, that addresses these problems. Our algorithm divides a complex colon anatomy into several smaller segments, and then splits each of these segments in half for display on a static medium. Multi-planar geometry clipping eliminates virtual colonoscopy's dependence upon expensive, real-time graphics workstations by enabling radiologists to globally inspect the entire internal surface of the colon from a single viewpoint.

  10. Parent artery occlusion for ruptured “true” posterior communicating artery aneurysm

    PubMed Central

    Takeda, Nobuaki; Oishi, Hidenori; Arai, Hajime

    2015-01-01

    A case of a patient with a ruptured true posterior communicating artery (PCoA) aneurysm is reported, who had been managed by early endovascular parent artery occlusion with coils. The small blister aneurysm was located at the proximal PCoA itself and directed superiorly. Postoperative course was uneventful. During 1-month follow-up, the patient recovered well and could care for herself. Aneurysms of the PCoA itself are very rare. As reported to date, surgical procedures would favor microsurgical clipping over endovascular coil embolization. Endovascular treatment may be a good alternative to surgical trapping for true PCoA blister aneurysm. PMID:25953771

  11. Comparative study of novel endovascular treatment techniques for intracranial aneurysms

    NASA Astrophysics Data System (ADS)

    Cantón, Gádor; Lasheras, Juan C.; Levy, David I.; Sparks, Steven R.

    2002-11-01

    Intracranial aneurysms are life-threatening vascular lesions, which are potentially treatable to avoid the consequences of their rupture. Current treatments, either surgical or endovascular, are all guided to reduce the hemodynamic forces acting on the aneurysm wall in an effort to minimize the risk of rupture. Surgical clipping is still the most used technique to treat this type of aneurysm but there is a continued demand for less invasive approaches. This has led to the development of several endovascular techniques. We report here a comparative study of the reduction in the hemodynamic stresses and the modification of the flow in the parent vessel resulting from the use of three different techniques. The first one consists of endosaccular packing with platinum coils (GDC, Target Therapeutics), which is already widely used but its long-term efficacy has not yet been determined. The second one consists of the embolization of the aneurismal sac with Onyx, a polymer which hardens when in contact with the blood (being developed by Micro Therapeutics, Inc.). The third one involves the packing of the sac with hydrocoils, platinum wires coated with a gel which quickly hydrates when in contact with blood (developed by MicroVention). A Digital Particle Image Velocimetry (DPIV) system is used to measure in vitro the velocity field inside a model of an ACOM aneurysm (an aneurysm forming in the anterior communicating artery). Physiological accurate pulsatile flow conditions are input to the arterial model through a programmable pump. The measurements show that although all treatment techniques lead to a reduction in both normal and tangential shear stresses on the aneurismal sac, each one of them also leads to different modifications of the flow in the parent vessel which may have consequences related to potential for clotting. Comparison of the untreated aneurysm with the above three treated cases also showed that the characteristics of the wall shear stresses on the parent vessel are modified by the packing method.

  12. Evaluation of Breast Sentinel Lymph Node Coverage by Standard Radiation Therapy Fields

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rabinovitch, Rachel; Ballonoff, Ari; Newman, Francis M.S.

    2008-04-01

    Background: Biopsy of the breast sentinel lymph node (SLN) is now a standard staging procedure for early-stage invasive breast cancer. The anatomic location of the breast SLN and its relationship to standard radiation fields has not been described. Methods and Materials: A retrospective review of radiotherapy treatment planning data sets was performed in patients with breast cancer who had undergone SLN biopsy, and those with a surgical clip at the SLN biopsy site were identified. The location of the clip was evaluated relative to vertebral body level on an anterior-posterior digitally reconstructed radiograph, treated whole-breast tangential radiation fields, and standardmore » axillary fields in 106 data sets meeting these criteria. Results: The breast SLN varied in vertebral body level position, ranging from T2 to T7 but most commonly opposite T4. The SLN clip was located below the base of the clavicle in 90%, and hence would be excluded from standard axillary radiotherapy fields where the inferior border is placed at this level. The clip was within the irradiated whole-breast tangent fields in 78%, beneath the superior-posterior corner multileaf collimators in 12%, and outside the tangent field borders in 10%. Conclusions: Standard axillary fields do not encompass the lymph nodes at highest risk of containing tumor in breast cancer patients. Elimination of the superior-posterior corner MLCs from the tangent field design would result in inclusion of the breast SLN in 90% of patients treated with standard whole-breast irradiation.« less

  13. Acute outcomes after MitraClip therapy in highly aged patients: results from the German TRAnscatheter Mitral valve Interventions (TRAMI) Registry.

    PubMed

    Schillinger, Wolfgang; Hünlich, Mark; Baldus, Stephan; Ouarrak, Taoufik; Boekstegers, Peter; Hink, Ulrich; Butter, Christian; Bekeredjian, Raffi; Plicht, Björn; Sievert, Horst; Schofer, Joachim; Senges, Jochen; Meinertz, Thomas; Hasenfuß, Gerd

    2013-05-20

    The influence of age on baseline demographics and outcomes of patients selected for MitraClip has not been previously investigated. Baseline demographics and acute outcomes in 1,064 patients from the German TRAMI registry were stratified by age (525 patients ≥76 years and 539 patients <76 years). In elderly patients, logistic EuroSCORE was higher (25[15-40]% vs. 18[10-31]%, p<0.0001) and the proportion of women was greater (47.2% vs. 29.3%, p<0.0001). Elderly patients were more likely to have preserved left ventricular ejection fraction >50% (40.1% vs. 21.8%, p<0.0001) and degenerative mitral regurgitation (DMR, 35.3% vs. 25.6%, p<0.01). Age was the most frequent reason for non-surgical treatment in the elderly (69.4% vs. 36.1%, p<0.0001). The intrahospital MACCE (death, myocardial infarction, stroke) was low in both groups (3.5% vs. 3.4%, p=0.93) and the proportion of non-severe mitral regurgitation at discharge was similar (95.8% vs. 96.4%, p=0.73). A logistic regression model did not reveal any significant impact of age on acute efficacy and safety of MitraClip therapy. In both groups, the majority of patients were discharged home (81.8% vs. 86.2%, p=0.06). Elderly and younger patients have similar benefits from MitraClip therapy. Age was the most frequent cause for denying surgery in elderly patients.

  14. Decision blocks: A tool for automating decision making in CLIPS

    NASA Technical Reports Server (NTRS)

    Eick, Christoph F.; Mehta, Nikhil N.

    1991-01-01

    The human capability of making complex decision is one of the most fascinating facets of human intelligence, especially if vague, judgemental, default or uncertain knowledge is involved. Unfortunately, most existing rule based forward chaining languages are not very suitable to simulate this aspect of human intelligence, because of their lack of support for approximate reasoning techniques needed for this task, and due to the lack of specific constructs to facilitate the coding of frequently reoccurring decision block to provide better support for the design and implementation of rule based decision support systems. A language called BIRBAL, which is defined on the top of CLIPS, for the specification of decision blocks, is introduced. Empirical experiments involving the comparison of the length of CLIPS program with the corresponding BIRBAL program for three different applications are surveyed. The results of these experiments suggest that for decision making intensive applications, a CLIPS program tends to be about three times longer than the corresponding BIRBAL program.

  15. A P300 event related potential technique for assessment of sexually oriented interest.

    PubMed

    Vardi, Yoram; Volos, Michal; Sprecher, Elliot; Granovsky, Yelena; Gruenwald, Ilan; Yarnitsky, David

    2006-12-01

    Despite all of the modern, sophisticated tests that exist for diagnosing and assessing male and female sexual disorders, to our knowledge there is no objective psychophysiological test to evaluate sexual arousal and interest. We provide preliminary data showing a decrease in auditory P300 wave amplitude during exposure to sexually explicit video clips and a significant correlation between the auditory P300 amplitude decrease and self-reported scores of sexual arousal and interest in the clips. A total of 30 healthy subjects were exposed to several blocks of auditory stimuli administered using an oddball paradigm. Baseline auditory P300 amplitudes were obtained and auditory stimuli were then delivered while viewing visual clips with 3 types of content, including sport, scenery and sex. Auditory P300 amplitude significantly decreased during viewing clips of all contents. Viewing sexual content clips caused a maximal decrease in P300 amplitude (p <0.0001). In addition, a high correlation was found between the amplitude decrease and scores on the sexual arousal questionnaire regarding the viewed clips (r = 0.61, p <0.001). In addition, the P300 amplitude decrease was significantly related to the sexual interest score (r = 0.37, p = 0.042) but not to interest in clips of nonsexual content. The change in auditory P300 amplitude during exposure to visual stimuli with sexual context seems to be an objective measure of subject sexual interest. This method might be applied to assess therapeutic intervention and as a diagnostic tool for assessing disorders of impaired libido or psychogenic sexual dysfunction.

  16. Smartphone Magnification Attachment: Microscope or Magnifying Glass

    NASA Astrophysics Data System (ADS)

    Hergemöller, Timo; Laumann, Daniel

    2017-09-01

    Today smartphones and tablets do not merely pervade our daily life, but also play a major role in STEM education in general, and in experimental investigations in particular. Enabling teachers and students to make use of these new techniques in physics lessons requires supplying capable and affordable applications. Our article presents the improvement of a low-cost technique turning smartphones into powerful magnifying glasses or microscopes. Adding only a 3D-printed clip attached to the smartphone's camera and inserting a small glass bead in this clip enables smartphones to take pictures with up to 780x magnification (see Fig. 1). In addition, the construction of the smartphone attachments helps to explain and examine the differences between magnifying glasses and microscopes, and shows that the widespread term "smartphone microscope" for this technique is inaccurate from a physics educational perspective.

  17. Parent artery occlusion for ruptured "true" posterior communicating artery aneurysm.

    PubMed

    Mitsuhashi, Takashi; Takeda, Nobuaki; Oishi, Hidenori; Arai, Hajime

    2015-04-01

    A case of a patient with a ruptured true posterior communicating artery (PCoA) aneurysm is reported, who had been managed by early endovascular parent artery occlusion with coils. The small blister aneurysm was located at the proximal PCoA itself and directed superiorly. Postoperative course was uneventful. During 1-month follow-up, the patient recovered well and could care for herself. Aneurysms of the PCoA itself are very rare. As reported to date, surgical procedures would favor microsurgical clipping over endovascular coil embolization. Endovascular treatment may be a good alternative to surgical trapping for true PCoA blister aneurysm. © The Author(s) 2015 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  18. Update of transcatheter valve treatment

    PubMed Central

    Liu, Xian-bao; Wang, Jian-an

    2013-01-01

    Transcatheter valve implantation or repair has been a very promising approach for the treatment of valvular heart diseases since transcatheter aortic valve implantation (TAVI) was successfully performed in 2002. Great achievements have been made in this field (especially TAVI and transcatheter mitral valve repair—MitraClip system) in recent years. Evidence from clinical trials or registry studies has proved that transcatheter valve treatment for valvular heart diseases is safe and effective in surgical high-risk or inoperable patients. As the evidence accumulates, transcatheter valve treatment might be an alterative surgery for younger patients with surgically low or intermediate risk valvular heart diseases in the near future. In this paper, the updates on transcatheter valve treatment are reviewed. PMID:23897785

  19. Patient-specific atrium models for training and pre-procedure surgical planning

    NASA Astrophysics Data System (ADS)

    Laing, Justin; Moore, John; Bainbridge, Daniel; Drangova, Maria; Peters, Terry

    2017-03-01

    Minimally invasive cardiac procedures requiring a trans-septal puncture such as atrial ablation and MitraClip® mitral valve repair are becoming increasingly common. These procedures are performed on the beating heart, and require clinicians to rely on image-guided techniques. For cases of complex or diseased anatomy, in which fluoroscopic and echocardiography images can be difficult to interpret, clinicians may benefit from patient-specific atrial models that can be used for training, surgical planning, and the validation of new devices and guidance techniques. Computed tomography (CT) images of a patient's heart were segmented and used to generate geometric models to create a patient-specific atrial phantom. Using rapid prototyping, the geometric models were converted into physical representations and used to build a mold. The atria were then molded using tissue-mimicking materials and imaged using CT. The resulting images were segmented and used to generate a point cloud data set that could be registered to the original patient data. The absolute distance of the two point clouds was compared and evaluated to determine the model's accuracy. The result when comparing the molded model point cloud to the original data set, resulted in a maximum Euclidean distance error of 4.5 mm, an average error of 0.5 mm and a standard deviation of 0.6 mm. Using our workflow for creating atrial models, potential complications, particularly for complex repairs, may be accounted for in pre-operative planning. The information gained by clinicians involved in planning and performing the procedure should lead to shorter procedural times and better outcomes for patients.

  20. Robotic-assisted laparoscopic radical nephrectomy using the Da Vinci Si system: how to improve surgeon autonomy. Our step-by-step technique.

    PubMed

    Davila, Hugo H; Storey, Raul E; Rose, Marc C

    2016-09-01

    Herein, we describe several steps to improve surgeon autonomy during a Left Robotic-Assisted Laparoscopic Radical Nephrectomy (RALRN), using the Da Vinci Si system. Our kidney cancer program is based on 2 community hospitals. We use the Da Vinci Si system. Access is obtained with the following trocars: Two 8 mm robotic, one 8 mm robotic, bariatric length (arm 3), 15 mm for the assistant and 12 mm for the camera. We use curved monopolar scissors in robotic arm 1, Bipolar Maryland in arm 2, Prograsp Forceps in arm 3, and we alternate throughout the surgery with EndoWrist clip appliers and the vessel sealer. Here, we described three steps and the use of 3 robotic instruments to improve surgeon autonomy. Step 1: the lower pole of the kidney was dissected and this was retracted upwards and laterally. This maneuver was performed using the 3rd robotic arm with the Prograsp Forceps. Step 2: the monopolar scissors was replaced (robotic arm 1) with the robotic EndoWrist clip applier, 10 mm Hem-o-Lok. The renal artery and vein were controlled and transected by the main surgeon. Step 3: the superior, posterolateral dissection and all bleeders were carefully coagulated by the surgeon with the EndoWrist one vessel sealer. We have now performed 15 RALRN following these steps. Our results were: blood loss 300 cc, console time 140 min, operating room time 200 min, anesthesia time 180 min, hospital stay 2.5 days, 1 incisional hernia, pathology: (13) RCC clear cell, (1) chromophobe and (1) papillary type 1. Tumor Stage: (5) T1b, (8) T2a, (2) T2b. We provide a concise, step-by-step technique for radical nephrectomy (RN) using the Da Vinci Si robotic system that may provide more autonomy to the surgeon, while maintaining surgical outcome equivalent to standard laparoscopic RN.

  1. Standardized access, display, and retrieval of medical video

    NASA Astrophysics Data System (ADS)

    Bellaire, Gunter; Steines, Daniel; Graschew, Georgi; Thiel, Andreas; Bernarding, Johannes; Tolxdorff, Thomas; Schlag, Peter M.

    1999-05-01

    The system presented here enhances documentation and data- secured, second-opinion facilities by integrating video sequences into DICOM 3.0. We present an implementation for a medical video server extended by a DICOM interface. Security mechanisms conforming with DICOM are integrated to enable secure internet access. Digital video documents of diagnostic and therapeutic procedures should be examined regarding the clip length and size necessary for second opinion and manageable with today's hardware. Image sources relevant for this paper include 3D laparoscope, 3D surgical microscope, 3D open surgery camera, synthetic video, and monoscopic endoscopes, etc. The global DICOM video concept and three special workplaces of distinct applications are described. Additionally, an approach is presented to analyze the motion of the endoscopic camera for future automatic video-cutting. Digital stereoscopic video sequences are especially in demand for surgery . Therefore DSVS are also integrated into the DICOM video concept. Results are presented describing the suitability of stereoscopic display techniques for the operating room.

  2. Endoluminal perforation of a magnetic antireflux device.

    PubMed

    Bauer, Margit; Meining, Alexander; Kranzfelder, Michael; Jell, Alissa; Schirren, Rebekka; Wilhelm, Dirk; Friess, Helmut; Feussner, Hubertus

    2015-12-01

    The history of surgical antireflux treatment is coined by the search for better alternatives to Nissen fundoplication. Implantable devices are one option, beginning with the "Angelchik" prosthesis 30 years ago. However, this procedure was left soon because of the high rate of foreign body connected problems (migration, perforation). A modern approach is a magnetic sphincter augmentation device (LINX Reflux Management System, Torax Medical, Shoreview, MN, USA), a magnetic chain which is implanted laparoscopically. Advantages reported are simplicity to apply and good results in reflux control, with up to now only rare complication rates as reported in the literature (Lipham et al. in Dis Esophagus, 2014). We report one case of erosion of the esophagus by a LINX system resulting in severe dysphagia. A complete endoluminal removal could be achieved by a prototype OTSC-clip remover. Complete remission could be achieved. The technique is presented in detail (video). In principle, total endoscopic removal of the LINX device is feasible in case of major erosion.

  3. Comparison of the efficacy of two combined therapies for peptic ulcer bleeding: adrenaline injection plus haemoclipping versus adrenaline injection followed by bipolar electrocoagulation

    PubMed Central

    Świdnicka-Siergiejko, Agnieszka; Wróblewski, Eugeniusz; Baniukiewicz, Andrzej; Dąbrowski, Andrzej

    2014-01-01

    Introduction Peptic ulcer remains the most frequent cause of upper gastrointestinal bleeding. Treatment of bleeding with simultaneous combination of two endoscopic techniques has proved to be more efficient than monotherapy. None of the published comparative studies of various contact coagulation modalities have confirmed the superiority of one of these techniques over the others. Aim To compare the therapeutic outcomes of the use of a device enabling both injection of adrenaline solution and bipolar electrocoagulation (A + BE) to those of combined adrenaline injection with mechanical therapy (haemostatic clips) (A + HC) in the treatment of peptic ulcer bleeding. Material and methods Fifty-two subjects with bleeding ulcers were assigned to the A + BE group, and 55 patients were treated with A + HC. Results Overall, treatment failed in 20 patients (20/107, 18.7%): in 10 individuals from the A + BE group (10/52; 18.2%) and in 10 individuals from the A + HC group (10/55; 19.2%) (p > 0.05). Primary haemostasis was not obtained in 7 patients (6.5%): in 4 patients in the A + BE group and in 3 patients in the A + HC group (p > 0.05). Ten individuals (9.3%) experienced recurrent bleeding during hospitalisation: 4 patients from the A + BE group and 6 patients from the A + HC group (p > 0.05). Finally, in 96.3% of the patients (n = 103) the endoscopic treatment proved efficient with regards to obtaining haemostasis during hospitalisation. Surgical intervention was required in 4 individuals (3.7%): 2 patients in the A + BE group and 2 patients treated with A + HC (p > 0.05). Three patients (2.8%) – all from the A + HC group – died during hospitalisation. No significant intergroup differences were documented with regards to the mean number of transfused blood units and the mean length of hospital stay. Conclusions The efficacy of combined endoscopic treatment of ulcer bleeding with a probe enabling simultaneous bipolar electrocoagulation and adrenaline injection seems comparable to the widely used dual technique of adrenaline injection and haemostatic clipping. PMID:25653731

  4. Transcatheter Treatment of Tricuspid Regurgitation Using Edge-to-Edge Repair: Procedural Results, Clinical Implications and Predictors for Success.

    PubMed

    Lurz, Philipp; Besler, Christian; Noack, Thilo; Forner, Anna Flo; Bevilacqua, Carmine; Seeburger, Joerg; Rommel, Karl-Philipp; Blazek, Stephan; Hartung, Philipp; Zimmer, Marion; Mohr, Friedrich; Schuler, Gerhard; Linke, Axel; Ender, Joerg; Thiele, Holger

    2018-04-10

    To analyze the feasibility, safety and effectiveness of Tricuspid valve (TV) repair using the MitraClip system in patients at high surgical risk. Forty-two elderly high-risk patients (76.8±7.3 years, EuroScore II 8.1±5.7) with isolated TR or combined TR and mitral regurgitation (MR) underwent edge-to-edge repair of the TV (n=11) or combined edge-to-edge repair of the TV and mitral valve (n=31). Procedural details, success rate, impact on TR severity and predictors for success at 30 day follow-up were analyzed. Successful edge-to-edge repair of TR was achieved in 35/42 patients (83%, 68 clips in total, 94% in the anteroseptal commissure, 6% in the posteroseptal commissure). In 5 patients, grasping of the leaflets was impossible and two patients had no decrease in TR after clipping. In those with procedural success, clipping of the TV led to a reduction in effective regurgitant orifice area by -62,5 % (from 0.8±0.4 to 0.3±0.2 cm2; p<0.0001). In both, patients with isolated TV and combined procedures, 6 minute walking distance improved (from 285±118 to 344±81 and 225±113 to 261±130 m, p=0.02 and 0.03, respectively). Predominant anteroseptal or central TR was identified as predictor of procedural success (p=0.025). Edge-to-edge repair of the TV is feasible with promising reduction in TR, which could result in clinical improvement.

  5. Surgical treatment for a ruptured true posterior communicating artery aneurysm arising on the fetal-type posterior communicating artery--two case reports and review of the literature.

    PubMed

    Nakano, Yoshiteru; Saito, Takeshi; Yamamoto, Junkoh; Takahashi, Mayu; Akiba, Daisuke; Kitagawa, Takehiro; Miyaoka, Ryo; Ueta, Kunihiro; Kurokawa, Toru; Nishizawa, Shigeru

    2011-12-01

    Only a small number of aneurysms arising on the posterior communicating artery itself (true Pcom aneurysm) have been reported. We report two cases of ruptured true Pcom aneurysms with some characteristic features of true Pcom aneurysm. A 43 year old man suffering from subarachnoid hemorrhage (SAH) had an aneurysm arising on the fetal-type Pcom artery itself, and underwent surgery for clipping. Most of the aneurysm was buried in the temporal lobe, so retraction of the temporal lobe was mandatory. During the retraction, premature rupture was encountered. After tentative dome clipping and the control of bleeding, complete clipping was achieved. Another patient, a 71 year old woman presenting with consciousness disturbance due to SAH, had an aneurysm on the fetal-type Pcom artery itself, and underwent surgery for clipping. It has been generally considered that hemodynamic factor plays an important role in the formation, the growth, and the rupture of the cerebral aneurysm. This factor is especially significant in true Pcom aneurysm formation and rupture. According to the literature, a combination of fetal type Pcom and formation of the true Pcom aneurysm has been reported in most cases (81.8%). Most of the aneurysm can be buried in the temporal lobe, and the retraction of the temporal lobe during the dissection of the neck would be necessary, which causes premature rupture of the true Pcom aneurysm. In the surgery for a true Pcom aneurysm, we should be aware of possible premature rupture when temporal lobe retraction is necessary.

  6. QPA-CLIPS: A language and representation for process control

    NASA Technical Reports Server (NTRS)

    Freund, Thomas G.

    1994-01-01

    QPA-CLIPS is an extension of CLIPS oriented towards process control applications. Its constructs define a dependency network of process actions driven by sensor information. The language consists of three basic constructs: TASK, SENSOR, and FILTER. TASK's define the dependency network describing alternative state transitions for a process. SENSOR's and FILTER's define sensor information sources used to activate state transitions within the network. Deftemplate's define these constructs and their run-time environment is an interpreter knowledge base, performing pattern matching on sensor information and so activating TASK's in the dependency network. The pattern matching technique is based on the repeatable occurrence of a sensor data pattern. QPA-CIPS has been successfully tested on a SPARCStation providing supervisory control to an Allen-Bradley PLC 5 controller driving molding equipment.

  7. Neuronavigated microvascular Doppler sonography for intraoperative monitoring of blood flow velocity changes during aneurysm surgery - a feasible monitoring technique.

    PubMed

    Malinova, Vesna; von Eckardstein, Kajetan; Rohde, Veit; Mielke, Dorothee

    2015-10-01

    The intraoperative microvascular Doppler sonography (iMDS) is a well-established tool in vascular surgery for blood flow velocity (BFV) monitoring, capable of detecting vessel occlusion. However, identification of subtotal vessel compromise is more difficult, since the measured BFV may substantially vary with changing insonation angles and insonated vessel segments. To keep these parameters constant we combined neuronavigation with iMDS (niMDS). The question was if niMDS allows the detection of subtotal vessel compromise in aneurysm surgery. During surgery, the 3-dimensional reconstruction of the CT-angiography, which was obtained routinely prior to surgery, was displayed by the neuronavigational system. Prior to clipping, neuronavigation was used to define target point and trajectory, which, by coupling the neuronavigational pointer with the Doppler probe, correspond to the insonated vessel segment and the insonation angle. After clipping, for each vessel segment, the same trajectory was used for all consecutive measurements. The mean BFVs pre- and post-clipping were documented. We performed 82 BFV-measurements in 39 aneurysm surgeries. Mean deviation between pre- and post-clipping BFV values was 2.12cm/s. There was a significant correlation between the mean BFV values before and after clipping (r=0.45 [95% CI 17-66%]; p=0.002). One patient experienced new neurological deficits due to occlusion of a perforating vessel that was not insonated. The study could not answer the question if niMDS can detect BFV changes after clipping indicating vessel compromise, as no subtotal vessel occlusion occurred in the 39 operations. However, we proofed that niMDS-measured BFVs only varied minimally in uncompromised vessels pre- and post-clipping, suggesting that vessel compromises might be easily detected during aneurysm surgery. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. Importance of Early Postoperative Body Temperature Management for Treatment of Subarachnoid Hemorrhage.

    PubMed

    Suehiro, Eiichi; Sadahiro, Hirokazu; Goto, Hisaharu; Oku, Takayuki; Oka, Fumiaki; Fujiyama, Yuichi; Shirao, Satoshi; Yoneda, Hiroshi; Koizumi, Hiroyasu; Ishihara, Hideyuki; Suzuki, Michiyasu

    2016-06-01

    The importance of acute-phase brain temperature management is widely accepted for prevention of exacerbation of brain damage by a high body temperature. In this study, we investigated the influence of body temperature in the early postoperative period on the outcomes of 62 patients with subarachnoid hemorrhage who were admitted to our department. Body temperature was measured from day 4 to day 14 after onset. The patients were divided into those treated with surgical clipping (clip group) and coil embolization (coil group), those graded I-III (mild) and IV-V (severe) based on the Hunt & Hess classification on admission, those with and without development of delayed cerebral ischemia (DCI), and those with favorable and poor outcomes. Body temperatures throughout the hospital stay were compared in each group. There was no significant difference in body temperature between the clip and coil groups or between the mild and severe groups, but body temperature was significantly higher in patients with DCI compared to those without DCI, and in patients with a poor outcome compared to those with a favorable outcome. Fever in the early postoperative period of subarachnoid hemorrhage is associated with development of DCI and a poor outcome. Copyright © 2016 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  9. Transcatheter treatment of severe tricuspid regurgitation with the MitraClip system.

    PubMed

    Hammerstingl, Christoph; Schueler, Robert; Malasa, Margarita; Werner, Nikos; Nickenig, Georg

    2016-03-07

    The aim of this study was to show technical principles and feasibility of transcatheter tricuspid valve repair by use of the MitraClip system. Three consecutive patients were treated successfully for severe symptomatic Tricuspid regurgitation. Three-dimensional transoesophageal echocardiography confirmed reduction of measured effective regurgitant orifice in all patients [effective regurgitant orifice area-baseline/post-procedure (cm(2)): 0.7/0.3; 1.5/0.8; 0.4/0.1], which was accompanied by an increase in left ventricular stroke volumes [baseline/post-procedure (mL): 42.8/45.4; 38/45; 35.2/45], decrease of measured levels of N terminal pro brain natriuretic peptide (pg/mL: baseline/post-procedure: 548/440; 2526/1702; 1754/623), and significant relief of clinical symptoms for chronic right heart failure in all patients. Transcatheter tricuspid valve repair by use of interventional edge-to-edge repair with the MitraClip system was feasible, and safe in three consecutive patients. Reduction of tricuspid insufficiency associates with relief of clinical symptoms for right heart failure. This strategy seems a promising treatment option for patients at prohibitive surgical risk. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.

  10. Development of a novel marking system for laparoscopic gastrectomy using endoclips with radio frequency identification tags: feasibility study in a canine model.

    PubMed

    Kojima, Fumitsugu; Sato, Toshihiko; Tsunoda, Shigeru; Takahata, Hiromi; Hamaji, Masatsugu; Komatsu, Teruya; Okada, Minoru; Sugiura, Tadao; Oshiro, Osamu; Sakai, Yoshiharu; Date, Hiroshi; Nakamura, Tatsuo

    2014-09-01

    Intraoperative identification of early gastric cancer is difficult to conduct during laparoscopic procedures. In this study, we investigated the feasibility and accuracy of a newly developed marking system using endoclips with radio frequency identification (RFID) tags in a canine model. RFID is a wireless near field communication technology. Among the open frequency bands available for medical use, 13.56 MHz is suitable for a surgical marking system because of the similar and linear signal decay both in air and in biological tissues. The proposed system consists of four parts: (a) endoclips with RFID tags, (b) endo-clip applier equipment, (c) laparoscopic locating probe, and (d) signal processing units with audio interface. In the experimental setting using canine models, RFID-tagged endoclips were applied to the mucosa of each dog's stomach. During the subsequent operation, the clips with RFID tags placed in five dogs were located by the detection of the RFID signal from the tag (RFID group), and the conventional clips in the other six dogs were located by finger palpation (FP group). The detected sites were marked by ablation on the serosal surface. Distance between the clips and the metal pin needles indicating ablated sites were measured with X-ray radiographs of the resected specimen. All clips were successfully detected by the marking system in the RFID group (10/10) and by finger palpation in the FP group (17/17). The medians of detection times were 31.5 and 25.0 s, respectively; the distances were 5.63 and 7.62 mm, respectively. The differences were not statistically significant. No adverse event related to the procedures was observed. Endoclips with RFID tags were located by our novel marking system in an experimental laparoscopic setting using canine stomachs with substantial accuracy comparable to conventional endoclips located by finger palpation through an open approach.

  11. High-frequency electroencephalographic activity in left temporal area is associated with pleasant emotion induced by video clips.

    PubMed

    Kortelainen, Jukka; Väyrynen, Eero; Seppänen, Tapio

    2015-01-01

    Recent findings suggest that specific neural correlates for the key elements of basic emotions do exist and can be identified by neuroimaging techniques. In this paper, electroencephalogram (EEG) is used to explore the markers for video-induced emotions. The problem is approached from a classifier perspective: the features that perform best in classifying person's valence and arousal while watching video clips with audiovisual emotional content are searched from a large feature set constructed from the EEG spectral powers of single channels as well as power differences between specific channel pairs. The feature selection is carried out using a sequential forward floating search method and is done separately for the classification of valence and arousal, both derived from the emotional keyword that the subject had chosen after seeing the clips. The proposed classifier-based approach reveals a clear association between the increased high-frequency (15-32 Hz) activity in the left temporal area and the clips described as "pleasant" in the valence and "medium arousal" in the arousal scale. These clips represent the emotional keywords amusement and joy/happiness. The finding suggests the occurrence of a specific neural activation during video-induced pleasant emotion and the possibility to detect this from the left temporal area using EEG.

  12. Percutaneous edge-to-edge mitral valve repair in high-surgical-risk patients: do we hit the target?

    PubMed

    Van den Branden, Ben J L; Swaans, Martin J; Post, Martijn C; Rensing, Benno J W M; Eefting, Frank D; Jaarsma, Wybren; Van der Heyden, Jan A S

    2012-01-01

    This study sought to assess the feasibility and safety of percutaneous edge-to-edge mitral valve (MV) repair in patients with an unacceptably high operative risk. MV repair for mitral regurgitation (MR) can be accomplished by use of a clip that approximates the free edges of the mitral leaflets. All patients were declined for surgery because of a high logistic EuroSCORE (>20%) or the presence of other specific surgical risk factors. Transthoracic echocardiography was performed before and 6 months after the procedure. Differences in New York Heart Association (NYHA) functional class, quality of life (QoL) using the Minnesota questionnaire, and 6-min walk test (6-MWT) distances were reported. Fifty-five procedures were performed in 52 patients (69.2% male, age 73.2 ± 10.1 years, logistic EuroSCORE 27.1 ± 17.0%). In 3 patients, partial clip detachment occurred; a second clip was placed successfully. One patient experienced cardiac tamponade. Two patients developed inguinal bleeding, of whom 1 needed surgery. Six patients (11.5%) died during 6-month follow-up (5 patients as a result of progressive heart failure and 1 noncardiac death). The MR grade before repair was ≥3 in 100%; after 6 months, a reduction in MR grade to ≤2 was present in 79% of the patients. Left ventricular (LV) end-diastolic diameter, LV ejection fraction, and systolic pulmonary artery pressure improved significantly. Accompanied improvements in NYHA functional class, QoL index, 6-MWT distances, and log N-terminal pro-B-type natriuretic peptide were observed. In a high-risk population, MR reduction can be achieved by percutaneous edge-to-edge valve repair, resulting in LV remodeling with improvement of functional capacity after 6 months. Copyright © 2012 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  13. Use of Fat Grafts in Facial Reconstruction on the Wounded Soldiers From the First World War (WWI) by Hippolyte Morestin (1869-1919).

    PubMed

    Benmoussa, Nadia; Hansen, Kevin; Charlier, Philippe

    2017-11-01

    During the Great War of 1914 to 1918, spectacular progress was made in the field of facial reconstruction. The sheer number and severity of facial lesions inflicted during the fighting obliged French and German surgeons to take a close interest in the treatment of patients wounded in such a manner. As head surgeon of the fifth division "blessés de la face" at the hospital of Val-de-Grace, Hippolyte Morestin was responsible for one of the largest surgical departments specializing in facial surgery and reconstruction during the war. During his time of service, he developed various surgical techniques such as autoplasties using cartilaginous and adipose grafts to reconstruct tissue defects. This study focuses primarily on the adipose graft techniques and their aesthetic outcome used by Morestin during and in the aftermath of World War I. This is a historical descriptive study. Our research is based on documents available at the museum and archives of the Val-de-Grace Army Health Service (hospital activity reports, pre- and postoperative patient photographs, newspaper clippings, documented accounts of ward nurses, wax anatomy models). Thirty-four clinical cases published by Hippolyte Morestin dealing with facial reconstruction during the World War I were studied. Fat was mainly used to fill craniofacial substance losses after carrying out often complex reconstructions. The surgical technique is well documented and subdivided into 3 succeeding procedures. Most of the time, the grafts were of autologous origin but sometimes heterologous samples were used. Although the primary objective was to increase volume, an improved quality of skin healing and better skin flexibility were observed. The fat thus allowed the filling of substance losses, and its positive effects on scarring were noticed even before the regenerative properties of the stem cells present in body fat were discovered. Hippolyte Morestin can be named one of the pioneers of facial reconstruction. A retroperspective analysis of his work with adipose grafts proves interesting because even though not being the first to apply this technique, he contributed, by means of experimentation and reproduction to proving it an innovative and useful method in facial reconstruction. It was not until the 1990s that adipose grafts were again applied under the name of lipostructure. Nowadays, they are commonly used in cosmetic and restorative surgery.

  14. Energy sources for laparoscopic colectomy: a prospective randomized comparison of conventional electrosurgery, bipolar computer-controlled electrosurgery and ultrasonic dissection. Operative outcome and costs analysis.

    PubMed

    Targarona, Eduardo Ma; Balague, Carmen; Marin, Juan; Neto, Rene Berindoague; Martinez, Carmen; Garriga, Jordi; Trias, Manuel

    2005-12-01

    The development of operative laparoscopic surgery is linked to advances in ancillary surgical instrumentation. Ultrasonic energy devices avoid the use of electricity and provide effective control of small- to medium-sized vessels. Bipolar computer-controlled electrosurgical technology eliminates the disadvantages of electrical energy, and a mechanical blade adds a cutting action. This instrument can provide effective hemostasis of large vessels up to 7 mm. Such devices significantly increase the cost of laparoscopic procedures, however, and the amount of evidence-based information on this topic is surprisingly scarce. This study compared the effectiveness of three different energy sources on the laparoscopic performance of a left colectomy. The trial included 38 nonselected patients with a disease of the colon requiring an elective segmental left-sided colon resection. Patients were preoperatively randomized into three groups. Group I had electrosurgery; vascular dissection was performed entirely with an electrosurgery generator, and vessels were controlled with clips. Group II underwent computer-controlled bipolar electrosurgery; vascular and mesocolon section was completed by using the 10-mm Ligasure device alone. In group III, 5-mm ultrasonic shears (Harmonic Scalpel) were used for bowel dissection, vascular pedicle dissection, and mesocolon transection. The mesenteric vessel pedicle was controlled with an endostapler. Demographics (age, sex, body mass index, comorbidity, previous surgery and diagnoses requiring surgery) were recorded, as were surgical details (operative time, conversion, blood loss), additional disposable instruments (number of trocars, EndoGIA charges, and clip appliers), and clinical outcome. Intraoperative economic costs were also evaluated. End points of the trial were operative time and intraoperative blood loss, and an intention-to-treat principle was followed. The three groups were well matched for demographic and pathologic features. Surgical time was significantly longer in patients operated on with conventional electrosurgery vs the Harmonic Scalpel or computed-based bipolar energy devices. This finding correlated with a significant reduction in intraoperative blood loss. Conversion to other endoscopic techniques was more frequent in Group I; however, conversion to open surgery was similar in all three groups. No intraoperative accident related to the use of the specific device was observed in any group. Immediate outcome was similar in the three groups, without differences in morbidity, mortality, or hospital stay. Analysis of operative costs showed no significant differences between the three groups. High-energy power sources specifically adapted for endoscopic surgery reduce operative time and blood loss and may be considered cost-effective when left colectomy is used as a model.

  15. CLIP-COSY: A Clean In-Phase Experiment for the Rapid Acquisition of COSY-type Correlations.

    PubMed

    Koos, Martin R M; Kummerlöwe, Grit; Kaltschnee, Lukas; Thiele, Christina M; Luy, Burkhard

    2016-06-27

    The COSY experiment is an essential homonuclear 2D NMR experiment for the assignment of resonances. Its multiplet line shape, however, is often overly complicated, potentially leads to signal intensity losses, and is responsible for long minimum overall acquisition times. Herein, we present CLIP-COSY, a COSY-type experiment yielding clean in-phase peaks. It can be recorded within a few minutes and benefits from enhanced signal intensities for most cross-peaks. In combination with non-uniform sampling, the experiment times can be further reduced, and the in-phase multiplets enable the application of modern homonuclear decoupling techniques in both dimensions. As antiphase cancelations are avoided, CLIP-COSY can also be applied to macromolecules and other samples with broadened lines. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Enhanced subcarrier-index modulation-based asymmetrically clipped optical OFDM using even subcarriers

    NASA Astrophysics Data System (ADS)

    Guan, Rui; Xu, Wei; Yang, Zhaohui; Huang, Nuo; Wang, Jin-Yuan; Chen, Ming

    2017-11-01

    In this paper, we propose a subcarrier-index modulation-based asymmetrically clipped optical orthogonal frequency division multiplexing (SACO-OFDM) scheme for optical wireless communication (OWC) systems, which benefits from the subcarrier-index modulation (SIM) and asymmetrically clipped optical orthogonal frequency division multiplexing (ACO-OFDM) techniques. SACO-OFDM conveys additional information via the subcarrier indexing, and the error rate of the bit transmitted by the subcarrier indexing is much lower than that of the conventional M-ary modulation scheme. On the other hand, as the signal constellation in M-ary modulation is relieved, SACO-OFDM has simple transceiver structure and low detection complexity. Moreover, considering the spectral, an enhanced SACO-OFDM (ESACO-OFDM) using even subcarriers is proposed. In this technique, the odd subcarriers are activated for SACO-OFDM, and the imaginary part of even subcarriers are activated for pulse-amplitude-modulated discrete multitone (PAM-DMT). Clearly, ESACO-OFDM achieves better spectral efficiency than the conventional optical OFDM, since all subcarriers are used for data transmission. Simulation results verify the significant bit error rate (BER) and peak-to-average power ratio (PAPR) improvement by the proposed ESACO-OFDM, especially for the medium-to-high signal-to-noise ratio (SNR) regime.

  17. Clipped Random Wave Morphologies and the Analysis of the SAXS of an Ionomer Formed by Copolymerization of Tetrafluoroethylene and CF[subscript 2]=CFO(CF[subscript 2])[subscript 4]SO[subscript 3]H

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aieta, Niccolo V.; Stanis, Ronald J.; Horan, James L.

    Using SAXS data, the microstructure of the ionomer formed by copolymerization of tetrafluoroethylene and CF{sub 2}=CFO(CF{sub 2}){sub 4}SO{sub 3}H films has been approached by two methods: a numerical method (the unified fit approach) utilizing a simple model of spherical scattering objects to determine the radius of gyration of different scattering features of the ionomer films and by a graphical method, the clipped random wave approach (CRW), using the scattering data and a porosity parameter to generate a random wave which is clipped to produce a real-space image of the microstructure. We studied films with EW of 733, 825, 900, andmore » 1082 in both the as-cast and annealed 'dry' and boiled 'wet' states. The results of the two data analysis techniques are in good size agreement with each other. In addition, the CRW model show striking similarities to the structure proposed in a recent dissipative particle dynamic models. This has been the first time to our knowledge that the CRW technique has been applied to a PFSA type ionomer.« less

  18. Complication Risk Factors in Anterior Choroidal Artery Aneurysm Treatment.

    PubMed

    André, Arthur; Boch, Anne-Laure; Di Maria, Federico; Nouet, Aurélien; Sourour, Nader; Clémenceau, Stéphane; Gabrieli, Joseph; Degos, Vincent; Zeghal, Chiheb; Chiras, Jacques; Cornu, Philippe; Clarençon, Frédéric

    2017-03-20

    The anterior choroidal artery (AChoA) is a rare location for intracranial aneurysms. The treatment of these aneurysms may be challenging due to the risk of occlusion of such a small and eloquent artery as the AChoA. We aimed to evaluate the risk factors for complications in AChoA aneurysm treatment. We retrospectively analyzed 47 consecutive AChoA aneurysms in 40 patients treated in our institution from 1999 and 2014 by endovascular means (87%) or surgical clipping (13%). Minor (transient or minor neurological deficits) and major complications (severe permanent neurological deficits or death) were systematically recorded. The influence of patient age, sex, aneurysm size, neck size, shape, dome-to-neck ratio and treatment technique on the occurrence of procedure-related complications was evaluated. Of the patients 11 experienced procedure-related complications (5 major, 6 minor). Aneurysms with multilobed shape were significantly associated with a higher procedure-related complication rate. There was a tendency for higher major procedure-related complication rate in small volume aneurysms. We did not find any association between the other factors analyzed and occurrence of procedure-related complications. Treatment of AChoA aneurysms has an acceptable complication risk. We did not find any significant differences between surgical and endovascular treatment in terms of procedure-related complication rates. Multilobed aneurysms were significantly associated with a higher procedure-related complication rate.

  19. Genome-Wide Profiling of RNA–Protein Interactions Using CLIP-Seq

    PubMed Central

    Stork, Cheryl; Zheng, Sika

    2017-01-01

    UV crosslinking immunoprecipitation (CLIP) is an increasingly popular technique to study protein–RNA interactions in tissues and cells. Whole cells or tissues are ultraviolet irradiated to generate a covalent bond between RNA and proteins that are in close contact. After partial RNase digestion, antibodies specific to an RNA binding protein (RBP) or a protein–epitope tag is then used to immunoprecipitate the protein–RNA complexes. After stringent washing and gel separation the RBP–RNA complex is excised. The RBP is protease digested to allow purification of the bound RNA. Reverse transcription of the RNA followed by high-throughput sequencing of the cDNA library is now often used to identify protein bound RNA on a genome-wide scale. UV irradiation can result in cDNA truncations and/or mutations at the crosslink sites, which complicates the alignment of the sequencing library to the reference genome and the identification of the crosslinking sites. Meanwhile, one or more amino acids of a crosslinked RBP can remain attached to its bound RNA due to incomplete digestion of the protein. As a result, reverse transcriptase may not read through the crosslink sites, and produce cDNA ending at the crosslinked nucleotide. This is harnessed by one variant of CLIP methods to identify crosslinking sites at a nucleotide resolution. This method, individual nucleotide resolution CLIP (iCLIP) circularizes cDNA to capture the truncated cDNA and also increases the efficiency of ligating sequencing adapters to the library. Here, we describe the detailed procedure of iCLIP. PMID:26965263

  20. Microsurgical Clipping of an Unruptured Carotid Cave Aneurysm: 3-Dimensional Operative Video.

    PubMed

    Tabani, Halima; Yousef, Sonia; Burkhardt, Jan-Karl; Gandhi, Sirin; Benet, Arnau; Lawton, Michael T

    2017-08-01

    Most aneurysms originating from the clinoidal segment of the internal carotid artery (ICA) are nowadays managed conservatively, treated endovascularly with coiling (with or without stenting) or flow diverters. However, microsurgical clip occlusion remains an alternative. This video demonstrates clip occlusion of an unruptured right carotid cave aneurysm measuring 7 mm in a 39-year-old woman. The patient opted for surgery because of concerns about prolonged antiplatelet use associated with endovascular therapy. After patient consent, a standard pterional craniotomy was performed followed by extradural anterior clinoidectomy. After dural opening and sylvian fissure split, a clinoidal flap was opened to enter the extradural space around the clinoidal segment. The dural ring was dissected circumferentially, freeing the medial wall of the ICA down to the sellar region and mobilizing the ICA out of its canal of the clinoidal segment. With the aneurysm neck in view, the aneurysm was clipped with a 45° angled fenestrated clip over the ICA. Indocyanine green angiography confirmed no further filling of the aneurysm and patency of the ICA. Complete aneurysm occlusion was confirmed with postoperative angiography, and the patient had no neurologic deficits (Video 1). This case demonstrates the importance of anterior clinoidectomy and thorough distal dural ring dissection for effective clipping of carotid cave aneurysms. Control of venous bleeding from the cavernous sinus with fibrin glue injection simplifies the dissection, which should minimize manipulation of the optic nerve. Knowledge of this anatomy and proficiency with these techniques is important in an era of declining open aneurysm cases. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. Impact of Right-Sided Aneurysm, Rupture Status, and Size of Aneurysm on Perforator Infarction Following Microsurgical Clipping of Posterior Communicating Artery Aneurysms with a Distal Transsylvian Approach.

    PubMed

    Tanabe, Jun; Ishikawa, Tatsuya; Moroi, Junta; Sakata, Yoshinori; Hadeishi, Hiromu

    2018-03-01

    Posterior communicating artery (PCoA) aneurysms are among the most common aneurysms. Because blockage of the PCoA and perforators can cause adverse outcomes, occlusion of these arteries by surgical clipping should be avoided. The impact of factors on PCoA perforator infarction when using a distal transsylvian approach for PCoA aneurysms was examined. A total of 183 patients underwent PCoA aneurysm clipping, excluding application of fenestrated clips. Patients were divided into 2 groups: patients with PCoA perforator infarction (infarction group) and patients without infarction (noninfarction group). Multiple factors were analyzed in the 2 groups. Twenty-two of the 183 patients (12.0%) showed perforator infarction, mainly on magnetic resonance imaging evaluation, resulting in permanent deficits in 2 patients (1.1%). The proportion of right-sided operations (86.4% vs. 53.4%; P = 0.005) and surgery for rupture (90.9% vs. 55.9%; P = 0.002) were significantly higher in the infarction group than in the noninfarction group. Aneurysms were significantly larger in the infarction group (8.4 ± 3.8 mm) than in the noninfarction group (6.3 ± 3.0 mm; P = 0.02). Ruptured status (odds ratio [OR], 7.35; P = 0.01), right side (OR, 5.19; P = 0.01), and aneurysm size (OR, 1.18; P = 0.02) remained independent predictors of perforator infarction on multivariate logistic regression analysis. Ruptured status, right side, and large PCoA aneurysm were independent predictors of PCoA perforator infarction. Symptoms due to PCoA perforating infarction were mostly transient and rarely affected outcomes. Copyright © 2018 Elsevier Inc. All rights reserved.

  2. Initial experience of percutaneous treatment of mitral regurgitation with MitraClip® therapy in Spain.

    PubMed

    Carrasco-Chinchilla, Fernando; Arzamendi, Dabit; Romero, Miguel; Gimeno de Carlos, Federico; Alonso-Briales, Juan Horacio; Li, Chi-Hion; Mesa, Maria Dolores; Arnold, Roman; Serrador Frutos, Ana María; Pan, Manuel; Roig, Eulalia; Rodríguez-Bailón, Isabel; de la Fuente Galán, Luis; Hernández, José María; Serra, Antonio; Suárez de Lezo, José

    2014-12-01

    Symptomatic mitral regurgitation has an unfavorable prognosis unless treated by surgery. However, the European registry of valvular heart disease reports that 49% of patients with this condition do not undergo surgery. Percutaneous treatment of mitral regurgitation with MitraClip® has been proved a safe, efficient adjunct to medical treatment in patients with this profile. The objective of the present study is to describe initial experience of MitraClip® therapy in Spain. Retrospective observational study including all patients treated between November 2011 and July 2013 at the 4 Spanish hospitals recording the highest numbers of implantations. A total of 62 patients (77.4% men) were treated, mainly for restrictive functional mitral regurgitation (85.4%) of grade III (37%) or grade IV (63%), mean (standard deviation) ejection fraction 36% (14%), and New York Heart Association functional class III (37%) or IV (63%). Device implantation was successful in 98% of the patients. At 1 year, 81.2% had mitral regurgitation ≤ 2 and 90.9% were in New York Heart Association functional class ≤ II. One periprocedural death occurred (sepsis at 20 days post-implantation) and another 3 patients died during follow-up (mean, 9.1 months). Two patients needed a second implantation due to partial dehiscence of the first device and 2 others underwent heart transplantation. In Spain, MitraClip® therapy has principally been aimed at patients with functional mitral regurgitation, significant systolic ventricular dysfunction, and high surgical risk. It is considered a safe alternative treatment, which can reduce mitral regurgitation and improve functional capacity. Copyright © 2014 Sociedad Española de Cardiología. Published by Elsevier Espana. All rights reserved.

  3. A technique system for the measurement, reconstruction and character extraction of rice plant architecture

    PubMed Central

    Li, Xumeng; Wang, Xiaohui; Wei, Hailin; Zhu, Xinguang; Peng, Yulin; Li, Ming; Li, Tao; Huang, Huang

    2017-01-01

    This study developed a technique system for the measurement, reconstruction, and trait extraction of rice canopy architectures, which have challenged functional–structural plant modeling for decades and have become the foundation of the design of ideo-plant architectures. The system uses the location-separation-measurement method (LSMM) for the collection of data on the canopy architecture and the analytic geometry method for the reconstruction and visualization of the three-dimensional (3D) digital architecture of the rice plant. It also uses the virtual clipping method for extracting the key traits of the canopy architecture such as the leaf area, inclination, and azimuth distribution in spatial coordinates. To establish the technique system, we developed (i) simple tools to measure the spatial position of the stem axis and azimuth of the leaf midrib and to capture images of tillers and leaves; (ii) computer software programs for extracting data on stem diameter, leaf nodes, and leaf midrib curves from the tiller images and data on leaf length, width, and shape from the leaf images; (iii) a database of digital architectures that stores the measured data and facilitates the reconstruction of the 3D visual architecture and the extraction of architectural traits; and (iv) computation algorithms for virtual clipping to stratify the rice canopy, to extend the stratified surface from the horizontal plane to a general curved surface (including a cylindrical surface), and to implement in silico. Each component of the technique system was quantitatively validated and visually compared to images, and the sensitivity of the virtual clipping algorithms was analyzed. This technique is inexpensive and accurate and provides high throughput for the measurement, reconstruction, and trait extraction of rice canopy architectures. The technique provides a more practical method of data collection to serve functional–structural plant models of rice and for the optimization of rice canopy types. Moreover, the technique can be easily adapted for other cereal crops such as wheat, which has numerous stems and leaves sheltering each other. PMID:28558045

  4. Short-term outcomes of laparoscopic D2 lymphadenectomy with complete mesogastrium excision for advanced gastric cancer.

    PubMed

    Xie, Daxing; Yu, Chaoran; Liu, Liang; Osaiweran, Hasan; Gao, Chun; Hu, Junbo; Gong, Jianping

    2016-11-01

    D2 lymphadenectomy has been widely accepted as a standard procedure of surgical treatment for local advanced gastric cancer [1, 2]. However, neither the dissection boundary nor the extent of the excision for perigastric soft tissues has been described [3-7]. Our previous researches demonstrate the existence of disseminated cancer cells in the mesogastrium [8, 9] and present an understandable mesogastrium model for gastrectomy [10]. Hence, the D2 lymphadenectomy plus complete mesogastrium excision (D2 + CME) is firstly proposed in this study, aiming to assess the safety, feasibility and corresponding short-term surgical outcomes. All of these patients underwent laparoscopy assisted D2 + CME radical gastrectomy with a curative R0 resection, and all the operations were performed by Prof. Jianping Gong, chief of GI surgery of Tongji Hospital, Huazhong University of Science and Technology. All participants provided informed written consent to participate in the study. This study was approved by the Tongji Hospital Ethics Committee. The standard surgical procedures in the video are described as follows. Dissect along the gastrocolic ligament and then toward the left colic flexture with special made gauze. Bluntly separate the adipose tissues to find fascia plane. Expose along the plane toward the splenic inferior polar area. Precede to the origins of left gastroepiploic vessels (LGEVs), clip and cut. All the mobilized adipose tissues in this area are defined as left gastroepiploic mesentery (LGEM) [10]. Next, turn to infra-pyloric area. Dissect the fascia plane between right gastroepiploic mesentery (RGEM) and transverse mesocolon. Turn to the pancreas head, remove the covering adipose tissues, identify the superior mesentery vein and expose the origins of right gastroepiploic vessels (RGEVs). Clip and cut. All the surrounding mobilized adipose tissues are defined as RGEM [10]. Move to the superior boarder of pancreas with the stomach reflected cephalad, incise the serosa and bluntly mobilize through the plane with gauze. Turn to the common hepatic artery (CHA), remove the adherent adipose tissue. Expose the root of left gastric vein, clip and cut. Dissect the thick sheath of left gastric artery, expose at the root, trip clip and cut. All mobilized lateral adipose tissues and dorsal parts are defined as left gastric mesentery (LGM) [10]. Toward right, dissect follow the CHA and hepatic portal vein (HPV). Next, move toward the left side of LGM and dissect along the splenic artery until reaching the posterior gastric wall. Move to the anterior area of stomach and divide the lesser omentum. Clean up the adipose tissue and nerves along the lesser curvature up to the gastroesophageal junction. Expose and cut the right gastric vessels (RGVs) where the mobilized adipose tissues are defined as right gastric mesentery (RGM) [10]. Reconstruction of the alimentary tract was done by extracorporeal anastomosis. Standard recovery protocols were followed in postoperative treatments. Fifty-four patients between September 2014 and March 2015 have been recruited with informed consent and underwent laparoscopic D2 + CME by a single surgeon. The mean number of retrieved regional lymph nodes was 35.04 ± 10.70 (range 14-55). The mean volume of blood loss was 12.44 ± 22.89 ml (range 5-100). The mean laparoscopic surgery time was 127.82 ± 17.63 min (range 110-165). The mean hospitalization time was 11.09 ± 4.28 days (range 8-28). No operative complication was observed during the hospitalization. The anatomical boundary of mesogastrium is well described and dissected within D2 + CME surgical process. It proves to be safely feasible and repeatable with less blood lost, qualified lymph nodes retrieval results and other improved short-term surgical outcomes in advanced gastric cancer. Meanwhile, potential disseminated cancer cells fall into the mesogastrium can be eradicated by D2 + CME.

  5. Combined use of clips and nylon snare ("tulip-bundle") as a rescue endoscopic bleeding control in a mallory-weiss syndrome.

    PubMed

    Ivekovic, Hrvoje; Radulovic, Bojana; Jankovic, Suzana; Markos, Pave; Rustemovic, Nadan

    2014-01-01

    Mallory-Weiss syndrome (MWS) accounts for 6-14% of all cases of upper gastrointestinal bleeding. Prognosis of patients with MWS is generally good, with a benign course and rare recurrence of bleeding. However, no strict recommendations exist in regard to the mode of action after a failure of primary endoscopic hemostasis. We report a case of an 83-year-old male with MWS and rebleeding after the initial endoscopic treatment with epinephrine and clips. The final endoscopic control of bleeding was achieved by a combined application of clips and a nylon snare in a "tulip-bundle" fashion. The patient had an uneventful postprocedural clinical course and was discharged from the hospital five days later. To the best of our knowledge, this is the first case report showing the "tulip-bundle" technique as a rescue endoscopic bleeding control in the esophagus.

  6. Development of innovative techniques for the endoscopic implantation and securing of a novel, wireless, miniature gastrostimulator (with videos)

    PubMed Central

    Deb, Sanchali; Tang, Shou-jiang; Abell, Thomas L.; McLawhorn, Tyler; Huang, Wen-Ding; Lahr, Christopher; To, S.D. Filip; Easter, Julie; Chiao, J.-C.

    2016-01-01

    Background Gastric stimulation via high-frequency, low-energy pulses can provide an effective treatment for gastric dysmotility; however, the current commercially available device requires surgical implantation for long-term stimulation and is powered by a nonrechargeable battery. Objective To test and describe endoscopic implantation techniques and testing of stimulation of a novel, wireless, batteryless, gastric electrical stimulation (GES) device. Design Endoscopic gastric implantation techniques were implemented, and in vivo gastric signals were recorded and measured in a non-survival swine model (n = 2; 50-kg animals). Intervention Five novel endoscopic gastric implantation techniques and stimulation of a novel, wireless, batteryless, GES device were tested on a non-survival swine model. Main Outcome Measurements Feasibility of 5 new endoscopic gastric implantation techniques of the novel, miniature, batteryless, wireless GES device while recording and measurement of in vivo gastric signals. Results All 5 of the novel endoscopic techniques permitted insertion and securing of the miniaturized gastrostimulator. By the help of these methods and miniaturization of the gastrostimulator, successful GES could be provided without any surgery. The metallic clip attachment was restricted to the mucosal surface, whereas the prototype tacks, prototype spring coils, percutaneous endoscopic gastrostomy wires/T-tag fasteners, and submucosal pocket endoscopic implantation methods attach the stimulator near transmurally or transmurally to the stomach. They allow more secure device attachment with optimal stimulation depth. Limitations Non-survival pig studies. Conclusion These 5 techniques have the potential to augment the utility of GES as a treatment alternative, to provide an important prototype for other dysmotility treatment paradigms, and to yield insights for new technological interfaces between non-invasiveness and surgery. PMID:22726478

  7. Preservation of keratinized mucosa around implants using a prefabricated implant-retained stent: a case-control study

    PubMed Central

    2016-01-01

    Purpose The aim of this study was to clinically assess the impact of a prefabricated implant-retained stent clipped over healing abutments on the preservation of keratinized mucosa around implants after implant surgery, and to compare it with horizontal external mattress sutures. Methods A total of 50 patients were enrolled in this study. In the test group, a prefabricated implant-retained stent was clipped on the healing abutment after implant surgery to replace the keratinized tissue bucco-apically. In the control group, horizontal external mattress sutures were applied instead of using a stent. After the surgical procedure, the width of the buccal keratinized mucosa was measured at the mesial, middle, and distal aspects of the healing abutment. The change in the width of the buccal keratinized mucosa was assessed at 1 and 3 months. Results Healing was uneventful in both groups. The difference of width between baseline and 1 month was −0.26±0.85 mm in the test group, without any statistical significance (P=0.137). Meanwhile, the corresponding difference in the control group was −0.74±0.73 mm and it showed statistical significance (P<0.001). The difference of width between baseline and 3 months was −0.57±0.97 mm in the test group and −0.86±0.71 mm in the control group. These reductions were statistically significant (P<0.05); however, there was no difference between the 2 groups. Conclusions Using a prefabricated implant-retained stent was shown to be effective in the preservation of the keratinized mucosa around implants and it was simple and straightforward in comparison to the horizontal external mattress suture technique. PMID:27800215

  8. Arsenic microdistribution and speciation in toenail clippings of children living in a historic gold mining area

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pearce, Dora C.; Dowling, Kim; Gerson, Andrea R.

    2010-05-04

    Arsenic is naturally associated with gold mineralization and elevated in some soils and mine waste around historical gold mining activity in Victoria, Australia. To explore uptake, arsenic concentrations in children's toenail clippings and household soils were measured, and the microdistribution and speciation of arsenic in situ in toenail clipping thin sections investigated using synchrotron-based X-ray microprobe techniques. The ability to differentiate exogenous arsenic was explored by investigating surface contamination on cleaned clippings using depth profiling, and direct diffusion of arsenic into incubated clippings. Total arsenic concentrations ranged from 0.15 to 2.1 {micro}g/g (n = 29) in clipping samples and frommore » 3.3 to 130 {micro}g/g (n = 22) in household soils, with significant correlation between transformed arsenic concentrations (Pearson's r = 0.42, P = 0.023) when household soil was treated as independent. In clipping thin sections (n = 2), X-ray fluorescence (XRF) mapping showed discrete layering of arsenic consistent with nail structure, and irregular arsenic incorporation along the nail growth axis. Arsenic concentrations were heterogeneous at 10 x 10 {micro}m microprobe spot locations investigated (< 0.1 to 13.3 {micro}g/g). X-ray absorption near-edge structure (XANES) spectra suggested the presence of two distinct arsenic species: a lower oxidation state species, possibly with mixed sulphur and methyl coordination (denoted As{sub (-S, -ch3)}{sup {approx}III}); and a higher oxidation state species (denoted As{sub (-O)}{sup {approx}V}). Depth profiling suggested that surface contamination was unlikely (n = 4), and XRF and XANES analyses of thin sections of clippings incubated in dry or wet mine waste, or untreated, suggested direct diffusion of arsenic occurred under moist conditions. These findings suggest that arsenic in soil contributes to some systemic absorption associated with periodic exposures among children resident in areas of historic gold mining activity in Victoria, Australia. Future studies are required to ascertain if adverse health effects are associated with current levels of arsenic uptake.« less

  9. Comparison of TOF MRA, Contrast-Enhanced MRA and Subtracted CTA from CTP in Residue Evaluation of Treated Intracranial Aneurysms.

    PubMed

    Dündar, Tolga Turan; Aralaşmak, Ayşe; Özdemir, Hüseyin; Seyithanoğlu, Mehmet Hakan; Uysal, Ömer; Toprak, Hüseyin; Kitiş, Serkan; Özek, Erdinç; Alkan, Alpay

    2017-10-18

    To compare effectiveness of contrast-enhanced MRA (CE-MRA), 3D-Time-of-flight MRA (3D-TOF-MRA) and subtracted CTA from CTP (sub-CTA) in residue evaluation of intracranial aneurysms treated either with coiling or clipping. Sixteen treated aneurysms, which were evaluated with three methods within two weeks after the operation, were enrolled. The success of each imaging techniques in demonstration of residue aneurysm and nearby vessels was compared by Fisher\\'s Exact Test. The differences among three was evaluated by Cochran\\'s Q test (p ≤ 0.05). Perfusion abnormality was noted in % 81 of clipped and none of coiled patients. Vessel visualization in the vicinity of aneurysm was better in sub-CTA, followed by CE-MRA. In clipped aneurysms, sub-CTA revealed residue aneurysms in % 16,7 of the patients while 3D-TOF-MRA and CE-MRA revealed none. In coiled aneurysms, CE-MRA revealed residue aneurysms in 100 %, and TOF-MRA in 33,3 % while sub-CTA revealed none. Although dramatic differences were noted in the evaluation of residue aneurysm as well as nearby vessel visualization, no statistical significance noted due to very few patients in subcategories Conclusion: This is first study comparing the effectiveness of CE-MRA, 3D-TOF MRA and sub-CTA in residue aneurysms evaluation. Vessel visualization in the vicinity of aneurysm was better in sub-CTA in all regardless of coiling or clipping. Residue aneurysms were more commonly revealed by CE-MRA in coiled patients and more commonly and better shown by sub-CTA in clipped patients in addition of showing perfusion abnormality that's is more common in clipped patients.

  10. Investigation of Sequence Clipping and Structural Heterogeneity of an HIV Broadly Neutralizing Antibody by a Comprehensive LC-MS Analysis

    NASA Astrophysics Data System (ADS)

    Ivleva, Vera B.; Schneck, Nicole A.; Gollapudi, Deepika; Arnold, Frank; Cooper, Jonathan W.; Lei, Q. Paula

    2018-05-01

    CAP256 is one of the highly potent, broadly neutralizing monoclonal antibodies (bNAb) designed for HIV-1 therapy. During the process development of one of the constructs, an unexpected product-related impurity was observed via microfluidics gel electrophoresis. A panel of complementary LC-MS analyses was applied for the comprehensive characterization of CAP256 which included the analysis of the intact and reduced protein, the middle-up approach, and a set of complementary peptide mapping techniques and verification of the disulfide bonds. The designed workflow allowed to identify a clip within a protruding acidic loop in the CDR-H3 region of the heavy chain, which can lead to the decrease of bNAb potency. This characterization explained the origin of the additional species reflected by the reducing gel profile. An intra-loop disulfide bond linking the two fragments was identified, which explained why the non-reducing capillary electrophoresis (CE) profile was not affected. The extensive characterization of CAP256 post-translational modifications was performed to investigate a possible cause of CE profile complexity and to illustrate other structural details related to this molecule's biological function. Two sites of the engineered Tyr sulfation were verified in the antigen-binding loop, and pyroglutamate formation was used as a tool for monitoring the extent of antibody clipping. Overall, the comprehensive LC-MS study was crucial to (1) identify the impurity as sequence clipping, (2) pinpoint the clipping location and justify its susceptibility relative to the molecular structure, (3) lead to an upstream process optimization to mitigate product quality risk, and (4) ultimately re-engineer the sequence to be clip-resistant. [Figure not available: see fulltext.

  11. Removal time and efficacy of Riddell Quick Release Face Guard Attachment System side clips during 1 football season.

    PubMed

    Gruppen, Tonia; Smith, Molly; Ganss, Andrea

    2012-01-01

    In the National Athletic Trainers' Association position statement, "Acute Management of the Cervical Spine-Injured Athlete," the technique recommended for face-mask (FM) removal is one that "creates the least head and neck motion, is performed most quickly, is the least difficult, and carries the least chance of failure." Industrial and technological advances in football helmet design and FM attachment systems might influence the efficacy of emergency FM removal. To examine the removal times and success rates of the Quick Release (QR) Face Guard Attachment System (Riddell Sports, Inc, Elyria, OH) throughout and at the conclusion of 1 season of play by a National Collegiate Athletic Association Division III football team competing in the Midwest. Controlled laboratory study. College laboratory. A total of 69 randomly selected Revolution IQ (Riddell Sports, Inc) football helmets fitted with the QR system were used. Each helmet was secured to a spine board, and investigators attempted to remove both of the QR side clips from the helmet with the Riddell insertion tool. Dependent variables included total time for removal of both QR side clips from the FM and success rate for removal of both side clips. The overall success rate for removal of both clips was 94.8% (164/173), whereas the mean times for removal of both clips ranged from 9.92 ± 12.06 seconds to 16.65 ± 20.97 seconds over 4 trial sessions. We found no differences among mean times for trial sessions throughout the season of play among the same helmets or among different helmets (P > .05). Removal time and success rate of the Riddell QR were satisfactory during and after 1 season of play despite use in various temperatures and precipitation.

  12. Ideal Internal Carotid Artery Trapping Technique without Bypass in a Patient with Insufficient Collateral Flow.

    PubMed

    Chung, Joon Ho; Shin, Yong Sam; Lim, Yong Cheol; Park, Minjung

    2009-04-01

    Internal carotid artery (ICA) trapping can be used for treating intracranial giant aneurysm, blood blister-like aneurysms and ICA rupture during the surgery. We present a novel ICA trapping technique which can be used with insufficient collaterals flow via anterior communicating artery (AcoA) and posterior communicating artery (PcoA). A patient was admitted with severe headache and the cerebral angiography demonstrated a typical blood blister-like aneurysm at the contralateral side of PcoA. For trapping the aneurysm, the first clip was placed at the ICA just proximal to the aneurysm whereas the distal clip was placed obliquely proximal to the origin of the PcoA to preserve blood flow from the PcoA to the distal ICA. The patient was completely recovered with good collaterals filling to the right ICA territories via AcoA and PcoA. This technique may be an effective treatment option for trapping the aneurysm, especially when the PcoA preservation is mandatory.

  13. Enhance Video Film using Retnix method

    NASA Astrophysics Data System (ADS)

    Awad, Rasha; Al-Zuky, Ali A.; Al-Saleh, Anwar H.; Mohamad, Haidar J.

    2018-05-01

    An enhancement technique used to improve the studied video quality. Algorithms like mean and standard deviation are used as a criterion within this paper, and it applied for each video clip that divided into 80 images. The studied filming environment has different light intensity (315, 566, and 644Lux). This different environment gives similar reality to the outdoor filming. The outputs of the suggested algorithm are compared with the results before applying it. This method is applied into two ways: first, it is applied for the full video clip to get the enhanced film; second, it is applied for every individual image to get the enhanced image then compiler them to get the enhanced film. This paper shows that the enhancement technique gives good quality video film depending on a statistical method, and it is recommended to use it in different application.

  14. Clipping the cosmos: the bias and bispectrum of large scale structure.

    PubMed

    Simpson, Fergus; James, J Berian; Heavens, Alan F; Heymans, Catherine

    2011-12-30

    A large fraction of the information collected by cosmological surveys is simply discarded to avoid length scales which are difficult to model theoretically. We introduce a new technique which enables the extraction of useful information from the bispectrum of galaxies well beyond the conventional limits of perturbation theory. Our results strongly suggest that this method increases the range of scales where the relation between the bispectrum and power spectrum in tree-level perturbation theory may be applied, from k(max) ∼ 0.1 to ∼0.7 hMpc(-1). This leads to correspondingly large improvements in the determination of galaxy bias. Since the clipped matter power spectrum closely follows the linear power spectrum, there is the potential to use this technique to probe the growth rate of linear perturbations and confront theories of modified gravity with observation.

  15. A failure to communicate: patients with cerebral aneurysms and vascular neurosurgeons

    PubMed Central

    King, J; Yonas, H; Horowitz, M; Kassam, A; Roberts, M

    2005-01-01

    Objective: To assess communication between vascular neurosurgeons and their patients with unruptured cerebral aneurysms about treatment options and expected outcomes. Methods: Vascular neurosurgeons and their patients with cerebral aneurysms were surveyed immediately following outpatient appointments in a neurosurgery clinic. Data collected included how well the patient understood their aneurysm treatment options, the risks of a poor outcome from various treatments, and the consensus "best" treatment. Patient and neurosurgeon responses were measured using Likert scales, multiple choice questions, and visual analogue scales. Agreement between patient and neurosurgeon was assessed with kappa scores. The Wilcoxon sign rank test was used to compare visual analogue scale responses. Results: Data for 44 patient–neurosurgeon pairs were collected. Only 61% of patient–neurosurgeon pairs agreed on the best treatment plan for the patient's aneurysm (κ = 0.51, moderate agreement). Among the neurosurgeons, agreement with their patients ranged from 82% (κ = 0.77, almost perfect agreement) to 52% (κ = 0.37, fair agreement). Patients estimated much higher risks of stroke or death from surgical clipping, endovascular embolisation, or no intervention compared with the estimates offered by their neurosurgeons (surgical clipping: patient 36% v neurosurgeon 13%, p<0.001; endovascular embolisation: patient 35% v neurosurgeon 19%, p = 0.040; and no intervention: patient 63% v neurosurgeon 25%, p<0.001). Conclusions: Following consultation with a vascular neurosurgeon, many patients with cerebral aneurysms have an inaccurate understanding of their aneurysm treatment plan and an exaggerated sense of the risks of aneurysmal disease and treatment. PMID:15774444

  16. Intraoperative monitoring for spinal radiculomedullary artery aneurysm occlusion treatment: What, when, and how long?

    PubMed

    Landriel, Federico; Baccanelli, Matteo; Hem, Santiago; Vecchi, Eduardo; Bendersky, Mariana; Yampolsky, Claudio

    2017-01-01

    Spinal radiculomedullary artery aneurysms are extremely rare. Treatment should be tailored to clinical presentation, distal aneurysm flow, and lesion anatomical features. When a surgical occlusion is planned, it is necessary to evaluate whether intraoperative monitoring (IOM) should be considered as an indispensable tool to prevent potential spinal cord ischemia. We present a patient with symptoms and signs of spinal subarachnoid hemorrhage resulting from the rupture of a T4 anterior radiculomedullary aneurysm who underwent open surgical treatment under motor evoked potential (MEP) monitoring. Due to the aneurysmal fusiform shape and preserved distal flow, the afferent left anterior radiculomedullary artery was temporarily clipped; 2 minutes after the clamping, the threshold stimulation level rose higher than 100 V, and at minute 3, MEPs amplitude became attenuated over 50%. This was considered as a warning criteria to leave the vessel occlusion. The radiculomedullary aneurysm walls were reinforced and wrapped with muscle and fibrin glue to prevent re-bleeding. The patient awoke from general anesthesia without focal neurologic deficit and made an uneventful recovery with complete resolution of her symptoms and signs. This paper attempts to build awareness of the possibility to cause or worsen a neurological deficit if a radiculomedullary aneurysm with preserved distal flow is clipped or embolized without an optimal IOM control. We report in detail MEP monitoring during the occlusion of a unilateral T4 segmental artery that supplies an anterior radiculomedullary artery aneurysm.

  17. A failure to communicate: patients with cerebral aneurysms and vascular neurosurgeons.

    PubMed

    King, J T; Yonas, H; Horowitz, M B; Kassam, A B; Roberts, M S

    2005-04-01

    To assess communication between vascular neurosurgeons and their patients with unruptured cerebral aneurysms about treatment options and expected outcomes. Vascular neurosurgeons and their patients with cerebral aneurysms were surveyed immediately following outpatient appointments in a neurosurgery clinic. Data collected included how well the patient understood their aneurysm treatment options, the risks of a poor outcome from various treatments, and the consensus "best" treatment. Patient and neurosurgeon responses were measured using Likert scales, multiple choice questions, and visual analogue scales. Agreement between patient and neurosurgeon was assessed with kappa scores. The Wilcoxon sign rank test was used to compare visual analogue scale responses. Data for 44 patient-neurosurgeon pairs were collected. Only 61% of patient-neurosurgeon pairs agreed on the best treatment plan for the patient's aneurysm (kappa = 0.51, moderate agreement). Among the neurosurgeons, agreement with their patients ranged from 82% (kappa = 0.77, almost perfect agreement) to 52% (kappa = 0.37, fair agreement). Patients estimated much higher risks of stroke or death from surgical clipping, endovascular embolisation, or no intervention compared with the estimates offered by their neurosurgeons (surgical clipping: patient 36% v neurosurgeon 13%, p<0.001; endovascular embolisation: patient 35% v neurosurgeon 19%, p = 0.040; and no patient 63% v neurosurgeon 25%, p<0.001). Following consultation with a vascular neurosurgeon, many patients with cerebral aneurysms have an inaccurate understanding of their aneurysm treatment plan and an exaggerated sense of the risks of aneurysmal disease and treatment.

  18. Crowd-sourced assessment of technical skills: an opportunity for improvement in the assessment of laparoscopic surgical skills.

    PubMed

    Deal, Shanley B; Lendvay, Thomas S; Haque, Mohamad I; Brand, Timothy; Comstock, Bryan; Warren, Justin; Alseidi, Adnan

    2016-02-01

    Objective, unbiased assessment of surgical skills remains a challenge in surgical education. We sought to evaluate the feasibility and reliability of Crowd-Sourced Assessment of Technical Skills. Seven volunteer general surgery interns were given time for training and then testing, on laparoscopic peg transfer, precision cutting, and intracorporeal knot-tying. Six faculty experts (FEs) and 203 Amazon.com Mechanical Turk crowd workers (CWs) evaluated 21 deidentified video clips using the Global Objective Assessment of Laparoscopic Skills validated rating instrument. Within 19 hours and 15 minutes we received 662 eligible ratings from 203 CWs and 126 ratings from 6 FEs over 10 days. FE video ratings were of borderline internal consistency (Krippendorff's alpha = .55). FE ratings were highly correlated with CW ratings (Pearson's correlation coefficient = .78, P < .001). We propose the use of Crowd-Sourced Assessment of Technical Skills as a reliable, basic tool to standardize the evaluation of technical skills in general surgery. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. Numerical simulations of post-surgical flow and thrombosis in basilar artery aneurysms

    NASA Astrophysics Data System (ADS)

    Seshadhri, Santhosh; Lawton, Michael; Boussel, Loic; Saloner, David; Rayz, Vitaliy

    2015-11-01

    Surgical treatment of basilar artery aneurysms presents a major challenge since it is crucial to preserve the flow to the vital brainstem perforators branching of the basilar artery. In some cases, basilar aneurysms can be treated by clipping vessels in order to induce flow reduction and aneurysm thrombosis. Patient-specific CFD models can provide guidance to clinicians by simulating postoperative flows resulting from alternative surgeries. Several surgical options were evaluated for four basilar aneurysm patients. Patient-specific models were generated from preoperative MR angiography and MR velocimetry data and modified to simulate different procedures. The Navier-Stokes equations were solved with a finite-volume solver Fluent. Virtual contrast injections were simulated by solving the advection-diffusion equation in order to estimate the flow residence time and determine thrombus-prone regions. The results indicated on procedures that reduce intra-aneurysmal velocities and flow regions which are likely to become thrombosed. Thus CFD modeling can help improve the outcome of surgeries altering the flow in basilar aneurysms.

  20. Videothoracoscopy and muscle flaps in the treatment of bronchial stump fistula.

    PubMed

    Kowalewski, J; Brocki, M; Galikowski, M; Kapron, K

    1999-01-01

    The aim of the paper is to report our surgical technique applied for treatment of broncho-pleural fistula (BPF) as well as the results of the treatment. From 1992 to 1998 we performed 127 pneumonectomies for lung cancer. In 5 cases (3.9%) bronchial stump insufficiency developed postoperatively. Three patients were treated by means of videothoracoscopy (the Multifire Endo Hernia Stapler was used to clipped the fistula). Rethoracotomy with myoplasty was performed four times in 3 patients. In one patient both the methods were employed. In 2 out of 3 cases videothoracoscopic treatment was successful and the patients were discharged without signs of BPF and pleural empyema. In one case the recurrence of the fistula occurred and the stump of the bronchus was successfully covered with the pectoral musce flap 3 days later. In two cases after rethoracotomy and myoplasty (one of them was reoperated twice) the recurrence of BPF occurred and both the patients died due to cardiopulmonary failure. Despite the limited experience, we think videothoracoscopy is worth considering as a tool for treatment of BPF.

  1. Posterior inferior cerebellar artery aneurysms: Anatomical variations and surgical strategies

    PubMed Central

    Singh, Rohit K.; Behari, Sanjay; Kumar, Vijendra; Jaiswal, Awadhesh K.; Jain, Vijendra K.

    2012-01-01

    Context: Posterior inferior cerebellar artery (PICA) aneurysms are associated with multiple anatomical variations of the parent vessel. Complexities in their surgical clipping relate to narrow corridors limited by brain-stem, petrous-occipital bones, and multiple neurovascular structures occupying the cerebellomedullary and cerebellopontine cisterns. Aims: The present study focuses on surgical considerations during clipping of saccular PICA aneurysms. Setting and Design: Tertiary care, retrospective study. Materials and Methods: In 20 patients with PICA aneurysms, CT angiogram/digital substraction angiogram was used to correlate the site and anatomical variations of aneurysms located on different segments of PICA with the approach selected, the difficulties encountered and the final outcome. Statistical Analysis: Comparison of means and percentages. Results: Aneurysms were located on PICA at: vertebral artery/basilar artery (VA/BA)-PICA (n=5); anterior medullary (n=4); lateral medullary (n=3); tonsillomedullary (n=4); and, telovelotonsillar (n=4) segments. The Hunt and Hess grade distribution was I in 15; II in 2; and, III in 3 patients (mean ictus-surgery interval: 23.5 days; range: 3-150 days). Eight patients had hydrocephalus. Anatomical variations included giant, thrombosed aneurysms; 2 PICA aneurysms proximal to an arteriovenous malformation; bilobed or multiple aneurysms; low PICA situated at the foramen magnum with a hypoplastic VA; and fenestrated PICA. The approaches included a retromastoid suboccipital craniectomy (n=9); midline suboccipital craniectomy (n=6); and far-lateral approach (n=5). At a follow-up (range 6 months-2.5 years), 13 patients had no deficits (modified Rankin score (mRS) 0); 2 were symptomatic with no significant disability (mRS1); 1 had mild disability (mRS2); 1 had moderately severe disability (mRS4); and 3 died (mRS6). Three mortalities were caused by vasospasm (2) and, rupture of unclipped second VA-BA junctional aneurysm (1). Conclusions: PICA aneurysms may present with only IVth ventricular blood without subarachnoid hemorrhage. PICA may have multiple anomalies and its aneurysms may be missed on CT angiograms. Surgical approach is influenced by VA-BA tortuosity and variations in anatomy, location of the VA-BA junction and the PICA aneurysm relative to the brain-stem, and the pattern of collateral supply. The special category of VA-PICA junctional aneurysms and its management; and, the multiple anatomical variations of PICA aneurysms, merit special surgical considerations and have been highlighted in this study. PMID:22639684

  2. Evaluation of coded wire tags for marking lake trout

    USGS Publications Warehouse

    Elrod, Joseph H.; Schneider, Clifford P.

    1986-01-01

    Among hatchery-reared lake trout (Salvelinus namaycush) of the 1979-1982 year classes stocked in New York waters of Lake Ontario, more than 3 million fish were marked with a coded wire tag (CWT) plus an adipose fin clip, and 1.5 million with only conventional fin clips. Altogether, 7,640 tags were recovered from fish collected with bottom trawls and gill nets or caught by anglers during 1980-1983. One person was able to extract and decipher 200 or more CWTs per day with about a 1% error rate in reading and recording codes. Presence of the CWT did not affect growth. The adipose fin clip did not regenerate. The occurrence of fish with an adipose fin clip but no CWT resulted primarily from the regeneration of paired fins among fish marked with a combination of the adipose fin and a paired fin. Loss of CWTs between marking and stocking (generally 4-5 months for fish stocked in spring and 1-8 d for fish stocked in fall) declined from nearly 11% for the 1979 year class stocked as fall fingerlings to less than 3% for the 1981 and 1982 year classes - a difference that primarily reflected improvements in instrumentation and tagging technique. The rate of CWT loss after the marked fish were stocked was probably less than 1% per year. The CWT is a reliable method for marking hatchery-reared lake trout. A large number of experimental groups can be uniquely marked, and fish from each group can be accurately identified throughout their life. Use of this technique should greatly facilitate evaluations of genetic strain, hatchery experience, condition at time of stocking, season of stocking, size at stocking, method of stocking and other factors that affect poststocking survival and performance of lake trout stocked in the Great Lakes.

  3. Which Clip? A Prospective Comparative Study of Retention Rates of Endoscopic Clips on Normal Mucosa and Ulcers in a Porcine Model

    PubMed Central

    Saxena, Payal; Ji-Shin, Eun; Haito-Chavez, Yamile; Valeshabad, Ali K.; Akshintala, Venkata; Aguila, Gerard; Kumbhari, Vivek; Ruben, Dawn S.; Lennon, Anne-Marie; Singh, Vikesh; Canto, Marcia; Kalloo, Anthony; Khashab, Mouen A.

    2014-01-01

    Background/Aim: There are currently no data on the relative retention rates of the Instinct clip, Resolution clip, and QuickClip2Long. Also, it is unknown whether retention rate differs when clips are applied to ulcerated rather than normal mucosa. The aim of this study is to compare the retention rates of three commonly used endoscopic clips. Materials and Methods: Six pigs underwent upper endoscopy with placement of one of each of the three types of clips on normal mucosa in the gastric body. Three mucosal resections were also performed to create “ulcers”. Each ulcer was closed with placement of one of the three different clips. Repeat endoscopy was performed weekly for up to 4 weeks. Results: Only the Instinct and Resolution clips remained attached for the duration of the study (4 weeks). At each time point, a greater proportion of Instinct clips were retained on normal mucosa, followed by Resolution clips. QuickClip2Long had the lowest retention rate on normal mucosa. Similar retention rates of Instinct clips and Resolution clips were seen on simulated ulcers, although both were superior to QuickClip2Long. However, the difference did not reach statistical significance. All QuickClip2Long clips were dislodged at 4 weeks in both the groups. Conclusions: The Resolution and Instinct clips have comparable retention rates and both appeared to be better than the QuickClip2Long on normal mucosa-simulated ulcers; however this did not reach statistical significance. Both the Resolution clip and the Instinct clip may be preferred in clinical situations when long-term clip attachment is required, including marking of tumors for radiotherapy and anchoring feeding tubes or stents. Either of the currently available clips may be suitable for closure of iatrogenic mucosal defects without features of chronicity. PMID:25434317

  4. dCLIP: a computational approach for comparative CLIP-seq analyses

    PubMed Central

    2014-01-01

    Although comparison of RNA-protein interaction profiles across different conditions has become increasingly important to understanding the function of RNA-binding proteins (RBPs), few computational approaches have been developed for quantitative comparison of CLIP-seq datasets. Here, we present an easy-to-use command line tool, dCLIP, for quantitative CLIP-seq comparative analysis. The two-stage method implemented in dCLIP, including a modified MA normalization method and a hidden Markov model, is shown to be able to effectively identify differential binding regions of RBPs in four CLIP-seq datasets, generated by HITS-CLIP, iCLIP and PAR-CLIP protocols. dCLIP is freely available at http://qbrc.swmed.edu/software/. PMID:24398258

  5. [Percutaneously implantable aortic valve: the JenaValve concept evolution].

    PubMed

    Figulla, Hans R; Ferrari, Markus

    2006-10-01

    Due to the increasing incidence of severe aortic stenosis in old and multimorbid patients, the percutaneous implantation of aortic valve-carrying stents has become an alternative to the surgical replacement of aortic valves. Starting in 1995, the authors developed a self-expanding stent which transferred the necessary forces for anchoring up to the aorta ascendens-a conception taken over from CoreValve. The further improvement of this idea over the past 11 years has led to a self-expanding, relatively short stent-valve system that is reliably positioned in the cusps of the old aortic valve and holds the old valve like a paper clip, thus transferring the holding forces physiologically. As compared to conventional systems, the sophisticated insertion catheter requires further chronic animal tests so as to represent a true alternative to the conventional surgical procedure.

  6. Metal artifact reduction for flat panel detector intravenous CT angiography in patients with intracranial metallic implants after endovascular and surgical treatment

    PubMed Central

    Pjontek, Rastislav; Önenköprülü, Belgin; Scholz, Bernhard; Kyriakou, Yiannis; Schubert, Gerrit A; Othman, Ahmed; Wiesmann, Martin; Brockmann, Marc A

    2016-01-01

    Background Flat panel detector CT angiography with intravenous contrast agent injection (IV CTA) allows high-resolution imaging of cerebrovascular structures. Artifacts caused by metallic implants like platinum coils or clips lead to degradation of image quality and are a significant problem. Objective To evaluate the influence of a prototype metal artifact reduction (MAR) algorithm on image quality in patients with intracranial metallic implants. Methods Flat panel detector CT after intravenous application of 80 mL contrast agent was performed with an angiography system (Artis zee; Siemens, Forchheim, Germany) using a 20 s rotation protocol (200° rotation angle, 20 s acquisition time, 496 projections). The data before and after MAR of 26 patients with a total of 34 implants (coils, clips, stents) were independently evaluated by two blinded neuroradiologists. Results MAR improved the assessability of the brain parenchyma and small vessels (diameter <1 mm) in the neighborhood of metallic implants and at a distance of 6 cm (p<0.001 each, Wilcoxon test). Furthermore, MAR significantly improved the assessability of parent vessel patency and potential aneurysm remnants (p<0.005 each, McNemar test). MAR, however, did not improve assessability of stented vessels. Conclusions When an intravenous contrast protocol is used, MAR significantly ameliorates the assessability of brain parenchyma, vessels, and treated aneurysms in patients with intracranial coils or clips. PMID:26346458

  7. Evaluation of an expert system for fault detection, isolation, and recovery in the manned maneuvering unit

    NASA Technical Reports Server (NTRS)

    Rushby, John; Crow, Judith

    1990-01-01

    The authors explore issues in the specification, verification, and validation of artificial intelligence (AI) based software, using a prototype fault detection, isolation and recovery (FDIR) system for the Manned Maneuvering Unit (MMU). They use this system as a vehicle for exploring issues in the semantics of C-Language Integrated Production System (CLIPS)-style rule-based languages, the verification of properties relating to safety and reliability, and the static and dynamic analysis of knowledge based systems. This analysis reveals errors and shortcomings in the MMU FDIR system and raises a number of issues concerning software engineering in CLIPs. The authors came to realize that the MMU FDIR system does not conform to conventional definitions of AI software, despite the fact that it was intended and indeed presented as an AI system. The authors discuss this apparent disparity and related questions such as the role of AI techniques in space and aircraft operations and the suitability of CLIPS for critical applications.

  8. Time reversal focusing of high amplitude sound in a reverberation chamber.

    PubMed

    Willardson, Matthew L; Anderson, Brian E; Young, Sarah M; Denison, Michael H; Patchett, Brian D

    2018-02-01

    Time reversal (TR) is a signal processing technique that can be used for intentional sound focusing. While it has been studied in room acoustics, the application of TR to produce a high amplitude focus of sound in a room has not yet been explored. The purpose of this study is to create a virtual source of spherical waves with TR that are of sufficient intensity to study nonlinear acoustic propagation. A parameterization study of deconvolution, one-bit, clipping, and decay compensation TR methods is performed to optimize high amplitude focusing and temporal signal focus quality. Of all TR methods studied, clipping is shown to produce the highest amplitude focal signal. An experiment utilizing eight horn loudspeakers in a reverberation chamber is done with the clipping TR method. A peak focal amplitude of 9.05 kPa (173.1 dB peak re 20 μPa) is achieved. Results from this experiment indicate that this high amplitude focusing is a nonlinear process.

  9. The effect of a performance-based intra-procedural checklist on a simulated emergency laparoscopic task in novice surgeons.

    PubMed

    El Boghdady, Michael; Tang, Benjie; Alijani, Afshin

    2017-05-01

    Surgical checklists are in use as means to reduce errors. Checklists are infrequently applied during emergency situations in surgery. We aimed to study the effect of a simple self-administered performance-based checklist on the laparoscopic task when applied during an emergency-simulated scenario. The aviation checklist for unexpected situations is commonly used for simulated training of pilots to handle emergency during flights. This checklist was adopted for use as a standardised-performance-based checklist during emergency surgical tasks. Thirty consented laparoscopic novices were exposed unexpectedly to a bleeding vessel in a laparoscopic virtual reality simulator as an emergency scenario. The task consisted of using laparoscopic clips to achieve haemostasis. Subjects were randomly allocated into two equal groups; those using the checklist that was applied once every 20 s (checklist group) and those without (control group). The checklist group performed significantly better in 5 out of 7 technical factors when compared to the control group: right instrument path length (m), median (IQR) 1.44 [1.22] versus 2.06 [1.70] (p = 0.029), right instrument angular path (degree) 312.10 (269.44 versus 541.80 [455.16] (p = 0.014), left instrument path length (m) 1.20 [0.60] versus 2.08 [2.02] (p = 0.004), and left instrument angular path (degree) 277.62 [132.11] versus 385.88 [428.42] (p = 0.017). The checklist group committed significantly fewer number of errors in the application of haemostatic clips, 3 versus 28 (p = 0.006). Although statistically not significant, total blood loss (lit) decreased in the checklist group from 0.83 [1.23] to 0.78 [0.28] (p = 0.724) and total time (sec) from 186.51 [145.69] to 125.14 [101.46] (p = 0.165). The performance-based intra-procedural checklist significantly enhanced the surgical task performance of novices in an emergency-simulated scenario.

  10. Magnetic resonance imaging metallic artifact of commonly encountered surgical implants and foreign material.

    PubMed

    Sutherland-Smith, James; Tilley, Brenda

    2012-01-01

    Magnetic resonance imaging (MRI) artifacts secondary to metallic implants and foreign bodies are well described. Herein, we provide quantitative data from veterinary implants including total hip arthroplasty implants, cranial cruciate repair implants, surgical screws, a skin staple, ligation clips, an identification microchip, ameroid constrictor, and potential foreign bodies including air gun and BB projectiles and a sewing needle. The objects were scanned in a gelatin phantom with plastic grid using standardized T2-weighted turbo-spin echo (TSE), T1-weighted spin echo, and T2*-weighted gradient recalled echo (GRE) image acquisitions at 1.5 T. Maximum linear dimensions and areas of signal voiding and grid distortion were calculated using a DICOM workstation for each sequence and object. Artifact severity was similar between the T2-weighted TSE and T1-weighted images, while the T2*-weighted images were most susceptible to artifact. Metal type influenced artifact size with the largest artifacts arising from steel objects followed by surgical stainless steel, titanium, and lead. For animals with metallic surgical implants or foreign bodies, the quantification of the artifact size will help guide clinicians on the viability of MRI. © 2012 Veterinary Radiology & Ultrasound.

  11. ALTERNATIVE TECHNIQUE FOR CHOLECYSTECTOMY COMPARABLE TO SINGLE PORT.

    PubMed

    Sabbag, Carlos; Blitzckow, Ana

    2017-01-01

    With the advancement of laparoscopic surgery, new techniques have been proposed and disseminated in order to reduce the surgical aggression and get better cosmetic results. To present alternative technique for videocholecystectomy comparable to single port technique using conventional material for laparoscopic surgery. Introduction of laparoscopic devices using two incisions; gallbladder traction with thread, exposition of Calot triangle, and ligature of cystic pedicle with polymer clips. Nine operations were carried out with this method, without complications and no increase in operative time, being compared to conventional videocholecistectomy, however vastly superior in aesthetic results. The technique is feasible, reproducible, showing benefits to patient´s safety. Com o avanço da cirurgia laparoscópica, novas técnicas têm sido propostas e difundidas com o objetivo de diminuir a agressão cirúrgica e obter melhores resultados estéticos. Apresentar técnica alternativa para videocolecistectomia similar à técnica de single port, contudo utilizando material convencional para cirurgia laparoscópica. Procedimento de videocolecistectomia com uso de duas incisões, exposição do trígono de Calot por tração da vesícula biliar com fio e ligadura dos elementos do hilo cístico com clipes de polímero. Foram realizadas nove operações com esse método, não se observando complicações e nem aumento do tempo operatório em relação à videocolecistectomia convencional, contudo com resultado estético grandemente superior. A técnica é factível, reprodutível e mostra benefícios e segurança ao paciente.

  12. Symptomatic delayed coil migration after balloon assisted embolization: An underreported adverse event?

    PubMed

    Fonseca, Lino; Najarro-Quispe, Rafael; Rodríguez-Hernández, Ana; Torné, Ramon; Gándara-Sabatini, Dario; Arikan, Fuat; Baños-Carrasco, Pilar

    2018-04-03

    Microsurgical clipping is still regarded as the gold-standard treatment for broad-neck intracranial aneurysms. New endovascular techniques like balloon or stent assisted coiling are quickly rising to the challenge and showing promising outcomes. As a result, broad-neck aneurysms are increasingly addressed by these techniques despite they have not been tested against clipping in a randomized controlled trial and long-term complications might be unknown yet. Intraprocedural coil migration has been well documented in the literature, but the same complication in a delayed fashion is scarcely reported. We present a case of delayed coil migration occurring after a balloon-assisted embolization of a wide-necked intracranial aneurysm and we perform a literature review for similar cases. We discuss how, despite seeming an extremely rare complication, with new endovascular techniques increasingly perceived as the safer option in any aneurysm, potential adverse events may become more frequent. Strategies proposed to address this developing scenario are also reviewed. Copyright © 2018 Sociedad Española de Neurocirugía. Publicado por Elsevier España, S.L.U. All rights reserved.

  13. DAI-CLIPS: Distributed, Asynchronous, Interacting CLIPS

    NASA Technical Reports Server (NTRS)

    Gagne, Denis; Garant, Alain

    1994-01-01

    DAI-CLIPS is a distributed computational environment within which each CLIPS is an active independent computational entity with the ability to communicate freely with other CLIPS. Furthermore, new CLIPS can be created, others can be deleted or modify their expertise, all dynamically in an asynchronous and independent fashion during execution. The participating CLIPS are distributed over a network of heterogeneous processors taking full advantage of the available processing power. We present the general framework encompassing DAI-CLIPS and discuss some of its advantages and potential applications.

  14. Intracranial aneurysms: optimized diagnostic tools call for thorough interdisciplinary treatment strategies.

    PubMed

    Mueller, Oliver M; Schlamann, Marc; Mueller, Daniela; Sandalcioglu, I Erol; Forsting, Michael; Sure, Ulrich

    2011-09-01

    Intracranial aneurysms (IAs) require deliberately selected treatment strategies as they are incrementally found prior to rupture and deleterious subarachnoid haemorrhage (SAH). Multiple and recurrent aneurysms necessitate both neurointerventionalists and neurosurgeons to optimize aneurysmal occlusion in an interdisciplinary effort. The present study was conducted to condense essential strategies from a single neurovascular centre with regard to the lessons learned. Medical charts of 321 consecutive patients treated for IAs at our centre from September 2008 until December 2010 were retrospectively analysed for clinical presentation of the aneurysms, multiplicity and treatment pathways. In addition, a selective Medline search was performed. A total of 321 patients with 492 aneurysms underwent occlusion of their symptomatic aneurysm: 132 (41.1%) individuals were treated surgically, 189 (58.2%) interventionally; 138 patients presented with a SAH, of these 44.2% were clipped and 55.8% were coiled. Aneurysms of the middle cerebral artery were primarily occluded surgically (88), whereas most of the aneurysms of the internal carotid artery and anterior communicating artery (114) were treated endovascularly. Multiple aneurysms (range 2-5 aneurysms/individual) were diagnosed in 98 patients (30.2%). During the study period 12 patients with recurrent aneurysms were allocated to another treatment modality (previously clip to coil and vice versa). Our data show that successful interdisciplinary occlusion of IAs is based on both neurosurgical and neurointerventional therapy. In particular, multiple and recurrent aneurysms require tailored individual approaches to aneurysmal occlusion. This is achieved by a consequent interdisciplinary pondering of the optimal strategy to occlude IAs in order to prevent SAH.

  15. Removal Time and Efficacy of Riddell Quick Release Face Guard Attachment System Side Clips During 1 Football Season

    PubMed Central

    Gruppen, Tonia; Smith, Molly; Ganss, Andrea

    2012-01-01

    Context In the National Athletic Trainers' Association position statement, “Acute Management of the Cervical Spine-Injured Athlete,” the technique recommended for face-mask (FM) removal is one that “creates the least head and neck motion, is performed most quickly, is the least difficult, and carries the least chance of failure.” Industrial and technological advances in football helmet design and FM attachment systems might influence the efficacy of emergency FM removal. Objective To examine the removal times and success rates of the Quick Release (QR) Face Guard Attachment System (Riddell Sports, Inc, Elyria, OH) throughout and at the conclusion of 1 season of play by a National Collegiate Athletic Association Division III football team competing in the Midwest. Design Controlled laboratory study. Setting College laboratory. Patients or Other Participants A total of 69 randomly selected Revolution IQ (Riddell Sports, Inc) football helmets fitted with the QR system were used. Intervention(s) Each helmet was secured to a spine board, and investigators attempted to remove both of the QR side clips from the helmet with the Riddell insertion tool. Main Outcome Measure(s) Dependent variables included total time for removal of both QR side clips from the FM and success rate for removal of both side clips. Results The overall success rate for removal of both clips was 94.8% (164/173), whereas the mean times for removal of both clips ranged from 9.92 ± 12.06 seconds to 16.65 ± 20.97 seconds over 4 trial sessions. We found no differences among mean times for trial sessions throughout the season of play among the same helmets or among different helmets (P > .05). Conclusions Removal time and success rate of the Riddell QR were satisfactory during and after 1 season of play despite use in various temperatures and precipitation. PMID:22889658

  16. Evaluation of pulse-oximetry oxygen saturation taken through skin protective covering

    PubMed Central

    James, Jyotsna; Tiwari, Lokesh; Upadhyay, Pramod; Sreenivas, Vishnubhatla; Bhambhani, Vikas; Puliyel, Jacob M

    2006-01-01

    Background The hard edges of adult finger clip probes of the pulse oximetry oxygen saturation (POOS) monitor can cause skin damage if used for prolonged periods in a neonate. Covering the skin under the probe with Micropore surgical tape or a gauze piece might prevent such injury. The study was done to see if the protective covering would affect the accuracy of the readings. Methods POOS was studied in 50 full-term neonates in the first week of life. After obtaining consent from their parents the neonates had POOS readings taken directly (standard technique) and through the protective covering. Bland-Altman plots were used to compare the new method with the standard technique. A test of repeatability for each method was also performed. Results The Bland-Altman plots suggest that there is no significant loss of accuracy when readings are taken through the protective covering. The mean difference was 0.06 (SD of 1.39) and 0.04 (SD 1.3) with Micropore and gauze respectively compared to the standard method. The mean difference was 0.22 (SD 0.23) on testing repeatability with the standard method. Conclusion Interposing Micropore or gauze does not significantly affect the accuracy of the POOS reading. The difference between the standard method and the new method was less than the difference seen on testing repeatability of the standard method. PMID:16677394

  17. Evaluation of pulse-oximetry oxygen saturation taken through skin protective covering.

    PubMed

    James, Jyotsna; Tiwari, Lokesh; Upadhyay, Pramod; Sreenivas, Vishnubhatla; Bhambhani, Vikas; Puliyel, Jacob M

    2006-05-06

    The hard edges of adult finger clip probes of the pulse oximetry oxygen saturation (POOS) monitor can cause skin damage if used for prolonged periods in a neonate. Covering the skin under the probe with Micropore surgical tape or a gauze piece might prevent such injury. The study was done to see if the protective covering would affect the accuracy of the readings. POOS was studied in 50 full-term neonates in the first week of life. After obtaining consent from their parents the neonates had POOS readings taken directly (standard technique) and through the protective covering. Bland-Altman plots were used to compare the new method with the standard technique. A test of repeatability for each method was also performed. The Bland-Altman plots suggest that there is no significant loss of accuracy when readings are taken through the protective covering. The mean difference was 0.06 (SD of 1.39) and 0.04 (SD 1.3) with Micropore and gauze respectively compared to the standard method. The mean difference was 0.22 (SD 0.23) on testing repeatability with the standard method. Interposing Micropore or gauze does not significantly affect the accuracy of the POOS reading. The difference between the standard method and the new method was less than the difference seen on testing repeatability of the standard method.

  18. Video segmentation and camera motion characterization using compressed data

    NASA Astrophysics Data System (ADS)

    Milanese, Ruggero; Deguillaume, Frederic; Jacot-Descombes, Alain

    1997-10-01

    We address the problem of automatically extracting visual indexes from videos, in order to provide sophisticated access methods to the contents of a video server. We focus on tow tasks, namely the decomposition of a video clip into uniform segments, and the characterization of each shot by camera motion parameters. For the first task we use a Bayesian classification approach to detecting scene cuts by analyzing motion vectors. For the second task a least- squares fitting procedure determines the pan/tilt/zoom camera parameters. In order to guarantee the highest processing speed, all techniques process and analyze directly MPEG-1 motion vectors, without need for video decompression. Experimental results are reported for a database of news video clips.

  19. Software Products

    NASA Technical Reports Server (NTRS)

    1993-01-01

    MAST is a decision support system to help in the management of dairy herds. Data is collected on dairy herds around the country and processed at regional centers. One center is Cornell University, where Dr. Lawrence Jones and his team developed MAST. The system draws conclusions from the data and summarizes it graphically. CLIPS, which is embedded in MAST, gives the system the ability to make decisions without user interaction. With this technique, dairy managers can identify herd problems quickly, resulting in improved animal health and higher milk quality. CLIPS (C Language Integrated Production System) was developed by NASA's Johnson Space Center. It is a shell for developing expert systems designed to permit research, development and delivery on conventional computers.

  20. Classroom Use. Clip and Save.

    ERIC Educational Resources Information Center

    Hubbard, Guy

    2002-01-01

    Presents background information on the Dutch artist, Frans Hals, focusing on his life and work. Includes classroom activities based on Hals works, such as a reproduction of his work, "Malle Babbe." Provides a discussion on the content of this painting and the techniques used. (CMK)

  1. Introduction of a simulation model for choledocho- and pancreaticojejunostomy.

    PubMed

    Narumi, Shunji; Toyoki, Yoshikazu; Ishido, Keinosuke; Kudo, Daisuke; Umehara, Minoru; Kimura, Norihisa; Miura, Takuya; Muroya, Takahiro; Hakamada, Kenichi

    2012-10-01

    Pancreaticoduodenectomy includes choledochojejunostomy and pancreaticojejunostomy, which require hand-sewn anastomoses. Educational simulation models for choledochojejunostomy and pancreaticojejunostomy have not been designed. We introduce a simulation model for choledochojejunostomy and pancreaticojejunostomy created with a skin closure pad and a vascular model. A wound closure pad and a vein model (4 mm diameter) were used as a stump model of the pancreas. Pancreaticojejunostomy was simulated with a stump model of the pancreas and a double layer bowel model; these models were stabilized in an end-to-side fashion on a magnetic board using magnetic clips. In addition, vein (6 or 8 mm diameter) and bowel models were used to simulate choledochojejunostomy. Pancreatic and hepatobiliary surgery are relatively rare, particularly in a community hospital although surgical residents wish to practice these procedures. Our simulator enables surgeons and surgical residents to practice choledocho- and pancreaticojejunostomy through open or laparoscopic approaches.

  2. Indocyanine green video-angiography as an aid to surgical treatment of spinal dural arteriovenous fistulae.

    PubMed

    Hettige, Samantha; Walsh, Daniel

    2010-03-01

    To illustrate the use of indocyanine green (ICG) video-angiography to confirm abolition of spinal dural arteriovenous fistula (SDAVF) and preserve the normal vascular anatomy intraoperatively. A 73-year-old woman presenting with progressive myelopathy was diagnosed with an SDAVF, where the origin of the fistula was in close proximity to the origin of the posterior spinal artery. ICG was injected intravenously. Using a filter on the microscope, dynamic filling of the abnormal vasculature was visualised. After applying a clip to the fistulous connection, we were able to see the successful interruption of the dural fistula, on-table in real time. ICG video angiography confirmed interruption of the fistula and preservation of the associated posterior spinal artery. We find the application of this relatively new technology has the potential to shorten operating times, gives additional reassurance of completeness of surgical treatment and preservation of normal spinal vasculature.

  3. Correction of clipped pixels in color images.

    PubMed

    Xu, Di; Doutre, Colin; Nasiopoulos, Panos

    2011-03-01

    Conventional images store a very limited dynamic range of brightness. The true luma in the bright area of such images is often lost due to clipping. When clipping changes the R, G, B color ratios of a pixel, color distortion also occurs. In this paper, we propose an algorithm to enhance both the luma and chroma of the clipped pixels. Our method is based on the strong chroma spatial correlation between clipped pixels and their surrounding unclipped area. After identifying the clipped areas in the image, we partition the clipped areas into regions with similar chroma, and estimate the chroma of each clipped region based on the chroma of its surrounding unclipped region. We correct the clipped R, G, or B color channels based on the estimated chroma and the unclipped color channel(s) of the current pixel. The last step involves smoothing of the boundaries between regions of different clipping scenarios. Both objective and subjective experimental results show that our algorithm is very effective in restoring the color of clipped pixels. © 2011 IEEE

  4. Efficacy and safety of the remOVE System for OTSC® and FTRD® clip removal: data from a PMCF analysis.

    PubMed

    Caputo, Antonio; Schmidt, Arthur; Caca, Karel; Bauerfeind, Peter; Schostek, Sebastian; Ho, Chi-Nghia; Gottwald, Thomas; Schurr, Marc O

    2018-06-01

    The remOVE System (Ovesco Endoscopy AG, Tuebingen, Germany) is a medical device for the endoscopic removal of OTSC or FTRD clips (Ovesco Endoscopy AG, Tuebingen, Germany). The aim of this paper is to assess the efficacy and safety of this system. A total of 74 patients underwent clip extraction. The standard removal procedure comprises fragmenting the clip by applying an electrical direct current pulse at two opposing sides of the clip. Clip fragmentation was successful in 72 of 74 patients (97.3%). In two cases (2.7%) clip fragmentation was not possible. In nine cases (12.2%) a clip fragment could not be removed and was left in place. Complications occurred in three cases (4.1%): two minor bleedings near the clip removal site (2.7%), and one superficial mucosal tear resulting from clip fragment extraction (1.4%). Based on this study, the use of the remOVE System for OTSC or FTRD clip removal can be considered safe and effective.

  5. Modified CLIP with objective liver reserve assessment retains prognosis prediction for patients with advanced hepatocellular carcinoma.

    PubMed

    Shao, Yu-Yun; Liu, Tsung-Hao; Lee, Ying-Hui; Hsu, Chih-Hung; Cheng, Ann-Lii

    2016-07-01

    The Cancer of the Liver Italian Program (CLIP) score is a commonly used staging system for hepatocellular carcinoma (HCC) helpful with predicting prognosis of advanced HCC. CLIP uses the Child-Turcotte-Pugh (CTP) score to evaluate liver reserve. A new scoring system, the albumin-bilirubin (ALBI) grade, has been proposed as they objectively evaluate liver reserve. We examined whether the modification of CLIP with ALBI retained its prognosis prediction for patients with advanced HCC. We included patients who received first-line antiangiogenic therapy for advanced HCC. Liver reserve was assessed using CTP and ALBI scores, which were then incorporated into CLIP and ALBI-CLIP, respectively. To assess their efficacies of prognostic prediction, the Cox's proportional hazard model and concordance indexes were used. A total of 142 patients were included; 137 of them were classified CTP A and 5 patients CTP B. Patients could be divided into four or five groups with different prognosis according to CLIP and ALBI-CLIP, respectively. Higher R(2) (0.249 vs 0.216) and lower Akaike information criterion (995.0 vs 1001.1) were observed for ALBI-CLIP than for CLIP in the Cox's model predicting overall survival. ALBI-CLIP remained an independent predictor for overall survival when CLIP and ALBI-CLIP were simultaneously incorporated in Cox's models allowing variable selection with adjustment for hepatitis etiology, treatment, and performance status. The concordance index was also higher for ALBI-CLIP than for CLIP (0.724 vs 0.703). Modification of CLIP scoring with ALBI, which objectively assesses liver reserve, retains and might have improved prognosis prediction for advanced HCC. © 2016 Journal of Gastroenterology and Hepatology Foundation and John Wiley & Sons Australia, Ltd.

  6. Rebleeding from clipped aneurysm after 35 years: Report of 2 cases

    PubMed Central

    Ishida, Atsushi; Matsuo, Seigo; Asakuno, Keizoh; Nemoto, Akio; Niimura, Kaku; Yoshimoto, Haruko; Shiramizu, Hideki; Yuzawa, Miki

    2015-01-01

    Background: A successfully applied clip for a ruptured aneurysm keeps the aneurysm's neck closed, preventing rerupture throughout the patient's life. Unfortunately, rebleeding from a clipped aneurysm does occur, but the likelihood declines with time. Since relatively old people suffer from subarachnoid hemorrhage, they die from diseases other than rebleeding, such as cancer. Therefore, rebleeding from a clipped aneurysm after two decades is quite rare. Case Description: Here, we report 2 cases of rerupture after an extremely long time since the initial clipping. In both cases, the old clip was removed, and the regrown gourd-shaped aneurysm was successfully obliterated. The clips in both cases were submitted to their manufacturers and inspected thoroughly. They were found to be second-generation, stainless steel clips, and were almost intact, even keeping their closing forces. In both cases, the clip existed on the surface of the newly made dome, and the previous dome completely disappeared. Conclusions: We experienced 2 cases of rebleeding from the clipped aneurysm after 35 years. In one of the cases, the clip was a Yasargil second generation stainless steel clip that retained its mechanical properties and surface elemental composition in vivo for a long time. These cases should be informative as they show extremely long-term course of a clip applied for a ruptured aneurysm. PMID:26322244

  7. Surgical approach to posterior inferior cerebellar artery aneurysms.

    PubMed

    La Pira, Biagia; Sturiale, Carmelo Lucio; Della Pepa, Giuseppe Maria; Albanese, Alessio

    2018-02-01

    The far-lateral is a standardised approach to clip aneurysms of the posterior inferior cerebellar artery (PICA). Different variants can be adopted to manage aneurysms that differ in morphology, topography, ruptured status, cerebellar swelling and surgeon preference. We distinguished five paradigmatic approaches aimed to manage aneurysms that are: proximal unruptured; proximal ruptured requiring posterior fossa decompression (PFD); proximal ruptured not requiring PFD; distal unruptured; distal ruptured. Preoperative planning in the setting of PICA aneurysm surgery is of paramount importance to perform an effective and safe procedure, to ensure an adequate PFD and optimal proximal control before aneurysm manipulation.

  8. Emergency cricothyrotomy-a comparative study of different techniques in human cadavers.

    PubMed

    Schober, Patrick; Hegemann, Martina C; Schwarte, Lothar A; Loer, Stephan A; Noetges, Peter

    2009-02-01

    Emergency cricothyrotomy is the final lifesaving option in "cannot intubate-cannot ventilate" situations. Fast, efficient and safe management is indispensable to reestablish oxygenation, thus the quickest, most reliable and safest technique should be used. Several cricothyrotomy techniques exist, which can be grouped into two categories: anatomical-surgical and puncture. We studied success rate, tracheal tube insertion time and complications of different techniques, including a novel cricothyrotomy scissors technique in human cadavers. Sixty-three inexperienced health care providers were randomly assigned to apply either an anatomical-surgical technique (standard surgical technique, n=18; novel cricothyrotomy scissors technique, n=14) or a puncture technique (catheter-over-needle technique, n=17; wire-guided technique, n=14). Airway access was almost always successful with the anatomical-surgical techniques (success rate in standard surgical group 94%, scissors group 100%). In contrast, the success rate was smaller (p<0.05) with the puncture techniques (catheter-over-needle group 82%, wire-guided technique 71%). Tracheal tube insertion time was faster overall (p<0.05) with anatomical-surgical techniques (standard surgical 78s [54-135], novel cricothyrotomy scissors technique 60s [42-82]; median [IQR]) than with puncture techniques (catheter-over-needle technique 74s [48-145], wire-guided technique 135s [116-307]). We observed fewer complications with anatomical-surgical techniques than with puncture techniques (p<0.001). In inexperienced health care personnel, anatomical-surgical techniques showed a higher success rate, a faster tracheal tube insertion time and a lower complication rate compared with puncture techniques, suggesting that they may be the techniques of choice in emergencies.

  9. Neurosurgeon academic impact is associated with clinical outcomes after clipping of ruptured intracranial aneurysms

    PubMed Central

    Ibrahim, George M.; Wang, Justin; Guha, Daipayan; Mamdani, Muhammad; Schweizer, Tom A.; Macdonald, R. Loch

    2017-01-01

    Background Surgeon-dependent factors such as experience and volume are associated with patient outcomes. However, it is unknown whether a surgeon’s research productivity could be related to outcomes. The main aim of this study is to investigate the association between the surgeon’s academic productivity and clinical outcomes following neurosurgical clipping of ruptured aneurysms. Methods We performed a post-hoc analysis of 3567 patients who underwent clipping of ruptured intracranial aneurysms in the randomized trials of tirilazad mesylate from 1990 to 1997. These trials included 162 centers and 156 surgeons from 21 countries. Primary and secondary outcomes were: Glasgow outcome scale score and mortality, respectively. Total publications, H-index, and graduate degrees were used as academic indicators for each surgeon. The association between outcomes and academic factors were assessed using a hierarchical logistic regression analysis, adjusting for patient covariates. Results Academic profiles were available for 147 surgeons, treating a total of 3307 patients. Most surgeons were from the USA (62, 42%), Canada (18, 12%), and Germany (15, 10%). On univariate analysis, the H-index correlated with better functional outcomes and lower mortality rates. In the multivariate model, patients under the care of surgeons with higher H-indices demonstrated improved neurological outcomes (p = 0.01) compared to surgeons with lower H-indices, without any significant difference in mortality. None of the other academic indicators were significantly associated with outcomes. Conclusion Although prognostication following surgery for ruptured intracranial aneurysms primarily depends on clinical and radiological factors, the academic impact of the operating neurosurgeon may explain some heterogeneity in surgical outcomes. PMID:28727832

  10. Neurosurgeon academic impact is associated with clinical outcomes after clipping of ruptured intracranial aneurysms.

    PubMed

    Alotaibi, Naif M; Ibrahim, George M; Wang, Justin; Guha, Daipayan; Mamdani, Muhammad; Schweizer, Tom A; Macdonald, R Loch

    2017-01-01

    Surgeon-dependent factors such as experience and volume are associated with patient outcomes. However, it is unknown whether a surgeon's research productivity could be related to outcomes. The main aim of this study is to investigate the association between the surgeon's academic productivity and clinical outcomes following neurosurgical clipping of ruptured aneurysms. We performed a post-hoc analysis of 3567 patients who underwent clipping of ruptured intracranial aneurysms in the randomized trials of tirilazad mesylate from 1990 to 1997. These trials included 162 centers and 156 surgeons from 21 countries. Primary and secondary outcomes were: Glasgow outcome scale score and mortality, respectively. Total publications, H-index, and graduate degrees were used as academic indicators for each surgeon. The association between outcomes and academic factors were assessed using a hierarchical logistic regression analysis, adjusting for patient covariates. Academic profiles were available for 147 surgeons, treating a total of 3307 patients. Most surgeons were from the USA (62, 42%), Canada (18, 12%), and Germany (15, 10%). On univariate analysis, the H-index correlated with better functional outcomes and lower mortality rates. In the multivariate model, patients under the care of surgeons with higher H-indices demonstrated improved neurological outcomes (p = 0.01) compared to surgeons with lower H-indices, without any significant difference in mortality. None of the other academic indicators were significantly associated with outcomes. Although prognostication following surgery for ruptured intracranial aneurysms primarily depends on clinical and radiological factors, the academic impact of the operating neurosurgeon may explain some heterogeneity in surgical outcomes.

  11. Metal artifact reduction for flat panel detector intravenous CT angiography in patients with intracranial metallic implants after endovascular and surgical treatment.

    PubMed

    Pjontek, Rastislav; Önenköprülü, Belgin; Scholz, Bernhard; Kyriakou, Yiannis; Schubert, Gerrit A; Nikoubashman, Omid; Othman, Ahmed; Wiesmann, Martin; Brockmann, Marc A

    2016-08-01

    Flat panel detector CT angiography with intravenous contrast agent injection (IV CTA) allows high-resolution imaging of cerebrovascular structures. Artifacts caused by metallic implants like platinum coils or clips lead to degradation of image quality and are a significant problem. To evaluate the influence of a prototype metal artifact reduction (MAR) algorithm on image quality in patients with intracranial metallic implants. Flat panel detector CT after intravenous application of 80 mL contrast agent was performed with an angiography system (Artis zee; Siemens, Forchheim, Germany) using a 20 s rotation protocol (200° rotation angle, 20 s acquisition time, 496 projections). The data before and after MAR of 26 patients with a total of 34 implants (coils, clips, stents) were independently evaluated by two blinded neuroradiologists. MAR improved the assessability of the brain parenchyma and small vessels (diameter <1 mm) in the neighborhood of metallic implants and at a distance of 6 cm (p<0.001 each, Wilcoxon test). Furthermore, MAR significantly improved the assessability of parent vessel patency and potential aneurysm remnants (p<0.005 each, McNemar test). MAR, however, did not improve assessability of stented vessels. When an intravenous contrast protocol is used, MAR significantly ameliorates the assessability of brain parenchyma, vessels, and treated aneurysms in patients with intracranial coils or clips. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  12. Images created in a model eye during simulated cataract surgery can be the basis for images perceived by patients during cataract surgery

    PubMed Central

    Inoue, M; Uchida, A; Shinoda, K; Taira, Y; Noda, T; Ohnuma, K; Bissen-Miyajima, H; Hirakata, A

    2014-01-01

    Purpose To evaluate the images created in a model eye during simulated cataract surgery. Patients and methods This study was conducted as a laboratory investigation and interventional case series. An artificial opaque lens, a clear intraocular lens (IOL), or an irrigation/aspiration (I/A) tip was inserted into the ‘anterior chamber' of a model eye with the frosted posterior surface corresponding to the retina. Video images were recorded of the posterior surface of the model eye from the rear during simulated cataract surgery. The video clips were shown to 20 patients before cataract surgery, and the similarity of their visual perceptions to these images was evaluated postoperatively. Results The images of the moving lens fragments and I/A tip and the insertion of the IOL were seen from the rear. The image through the opaque lens and the IOL without moving objects was the light of the surgical microscope from the rear. However, when the microscope light was turned off after IOL insertion, the images of the microscope and operating room were observed by the room illumination from the rear. Seventy percent of the patients answered that the visual perceptions of moving lens fragments were similar to the video clips and 55% reported similarity with the IOL insertion. Eighty percent of the patients recommended that patients watch the video clip before their scheduled cataract surgery. Conclusions The patients' visual perceptions during cataract surgery can be reproduced in the model eye. Watching the video images preoperatively may help relax the patients during surgery. PMID:24788007

  13. A random approach of test macro generation for early detection of hotspots

    NASA Astrophysics Data System (ADS)

    Lee, Jong-hyun; Kim, Chin; Kang, Minsoo; Hwang, Sungwook; Yang, Jae-seok; Harb, Mohammed; Al-Imam, Mohamed; Madkour, Kareem; ElManhawy, Wael; Kwan, Joe

    2016-03-01

    Multiple-Patterning Technology (MPT) is still the preferred choice over EUV for the advanced technology nodes, starting the 20nm node. Down the way to 7nm and 5nm nodes, Self-Aligned Multiple Patterning (SAMP) appears to be one of the effective multiple patterning techniques in terms of achieving small pitch of printed lines on wafer, yet its yield is in question. Predicting and enhancing the yield in the early stages of technology development are some of the main objectives for creating test macros on test masks. While conventional yield ramp techniques for a new technology node have relied on using designs from previous technology nodes as a starting point to identify patterns for Design of Experiment (DoE) creation, these techniques are challenging to apply in the case of introducing an MPT technique like SAMP that did not exist in previous nodes. This paper presents a new strategy for generating test structures based on random placement of unit patterns that can construct more meaningful bigger patterns. Specifications governing the relationships between those unit patterns can be adjusted to generate layout clips that look like realistic SAMP designs. A via chain can be constructed to connect the random DoE of SAMP structures through a routing layer to external pads for electrical measurement. These clips are decomposed according to the decomposition rules of the technology into the appropriate mandrel and cut masks. The decomposed clips can be tested through simulations, or electrically on silicon to discover hotspots. The hotspots can be used in optimizing the fabrication process and models to fix them. They can also be used as learning patterns for DFM deck development. By expanding the size of the randomly generated test structures, more hotspots can be detected. This should provide a faster way to enhance the yield of a new technology node.

  14. Automated rule-base creation via CLIPS-Induce

    NASA Technical Reports Server (NTRS)

    Murphy, Patrick M.

    1994-01-01

    Many CLIPS rule-bases contain one or more rule groups that perform classification. In this paper we describe CLIPS-Induce, an automated system for the creation of a CLIPS classification rule-base from a set of test cases. CLIPS-Induce consists of two components, a decision tree induction component and a CLIPS production extraction component. ID3, a popular decision tree induction algorithm, is used to induce a decision tree from the test cases. CLIPS production extraction is accomplished through a top-down traversal of the decision tree. Nodes of the tree are used to construct query rules, and branches of the tree are used to construct classification rules. The learned CLIPS productions may easily be incorporated into a large CLIPS system that perform tasks such as accessing a database or displaying information.

  15. Internalization of Listeria monocytogenes in cantaloupes during dump tank washing and hydrocooling.

    PubMed

    Macarisin, Dumitru; Wooten, Anna; De Jesus, Antonio; Hur, Minji; Bae, Seonjae; Patel, Jitendra; Evans, Peter; Brown, Eric; Hammack, Thomas; Chen, Yi

    2017-09-18

    Recent listeriosis outbreaks and recalls associated with cantaloupes urge for studies to understand the mechanisms of cantaloupe contamination by Listeria monocytogenes. Postharvest practices such as washing and hydrocooling were suggested to facilitate the contamination of fresh fruits by human pathogens. This study assessed the potential of L. monocytogenes internalization into cantaloupes during dump tank washing and immersion-type hydrocooling in water contaminated with L. monocytogenes. The effect of cantaloupe cultivar, water temperature, and harvesting technique on L. monocytogenes internalization was also evaluated. Full slip (cantaloupe without any residual stem) Western and Eastern cultivar cantaloupes were pre-warmed to 42°C (to imitate peak-high field temperatures of freshly harvested cantaloupes) and then immersed in water at 6°C and 18°C containing 4 and 6logCFU/ml of L. monocytogenes. Clipped (cantaloupe with short stem residues obtained by clipping the stem at harvest) Western and Eastern cantaloupes were pre-warmed to 42°C and then immersed in water at 6°C containing 6logCFU/ml of L. monocytogenes. Additionally, full slip and clipped Western cantaloupes were equilibrated to 18°C and then immersed in water at 18°C containing 6logCFU/ml of L. monocytogenes (isothermal immersion without temperature differential). Water containing L. monocytogenes infiltrated both full slip and clipped cantaloupes through the stems/stem scars and was then distributed along the vascular system in hypodermal mesocarp reaching the calyx area of the fruit. The current study demonstrated that, under experimental conditions, L. monocytogenes can internalize into cantaloupes during immersion in water contaminated by L. monocytogenes, both in the presence and absence of temperature differential, and that temperature differential moderately enhanced the internalization of L. monocytogenes. The incidence and levels of L. monocytogenes internalized in the middle-mesocarp were significantly affected by harvesting technique but not by cantaloupe cultivar. Published by Elsevier B.V.

  16. Management of necrotising appendicitis associated with widespread necrotising enterocolitis of the small and large bowel and perforated duodenal ulcer.

    PubMed

    Gupta, Vaibhav; Zani, Augusto; Jackson, Paul; Singh, Shailinder

    2015-06-08

    A 7-year-old boy presented in septic shock secondary to appendicitis with generalised peritonitis. Following crystalloid resuscitation, he underwent surgery. Faecopurulent contamination and free air were found. This was secondary to a perforated and gangrenous appendix, multiple large and small bowel segments with perforations, patches of necrosis, interspersed with healthy bowel and segments of questionable viability. There was also a perforated duodenal ulcer. Necrotic segments were resected using a 'clip-and-drop' technique to shorten operative duration and guide resection to preserve bowel length. After six laparotomies and multiple bowel resections, the child was discharged home with an ileostomy that was subsequently reversed. He is currently on a normal diet and pursuing all activities appropriate for his age. Perforated appendicitis can be associated with widespread bowel necrosis and multiple perforations. A conservative damage limitation approach using the 'clip-and-drop' technique and relook laparotomies is useful in the management of extensive bowel necrosis in children. 2015 BMJ Publishing Group Ltd.

  17. Current Treatment Strategies for Intracranial Aneurysms: An Overview

    PubMed Central

    Lin, Hao; Summers, Richard; Yang, Mingmin; Cousins, Brian G.

    2017-01-01

    Intracranial aneurysm is a leading cause of stroke. Its treatment has evolved over the past 2 decades. This review summarizes the treatment strategies for intracranial aneurysms from 3 different perspectives: open surgery approach, transluminal treatment approach, and new technologies being used or trialed. We introduce most of the available treatment techniques in detail, including contralateral clipping, wrapping and clipping, double catheters assisting coiling and waffle-cone technique, and so on. Data from major trials such as Analysis of Treatment by Endovascular approach of Non-ruptured Aneurysms (ATENA), Internal Subarachnoid Trial (ISAT), Clinical and Anatomical Results in the Treatment of Ruptured Intracranial Aneurysms (CLARITY), and Barrow Ruptured Aneurysm Trial (BRAT) as well as information from other clinical reports and local experience are reviewed to suggest a clinical pathway for treating different types of intracranial aneurysms. It will be a valuable supplement to the current existing guidelines. We hope it could help assisting real-time decision-making in clinical practices and also encourage advancements in managing the disease. PMID:28355880

  18. CLIPS++: Embedding CLIPS into C++

    NASA Technical Reports Server (NTRS)

    Obermeyer, Lance; Miranker, Daniel P.

    1994-01-01

    This paper describes a set of C++ extensions to the CLIPS language and their embodiment in CLIPS++. These extensions and the implementation approach of CLIPS++ provide a new level of embeddability with C and C++. These extensions are a C++ include statement and a defcontainer construct; (include (c++-header-file.h)) and (defcontainer (c++-type)). The include construct allows C++ functions to be embedded in both the LHS and RHS of CLIPS rules. The header file in an include construct is the same header file the programmer uses for his/her own C++ code, independent of CLIPS. The defcontainer construct allows the inference engine to treat C++ class instances as CLIPS deftemplate facts. Consequently existing C++ class libraries may be transparently imported into CLIPS. These C++ types may use advanced features like inheritance, virtual functions, and templates. The implementation has been tested with several class libraries, including Rogue Wave Software's Tools.h++, GNU's libg++, and USL's C++ Standard Components. The execution speed of CLIPS++ has been determined to be 5 to 700 times the execution speed of CLIPS 6.0 (10 to 20X typical).

  19. A new improved technique for placement of a pursestring suture on the edge of the distal part of the rectal stump using a skin stapler for low anterior resection.

    PubMed

    Kumashiro, R; Sano, C; Ugaeri, H; Madokoro, S; Maekawa, T; Kumamoto, M; Hideshima, T; Inutsuka, S

    1994-04-01

    Instead of a linear stapler or manual pursestring suture onto the lower part of the rectum, we placed a No. 2-0 Prolene suture on the edge of the rectal stump, using 12 to 16 clips and a disposable skin stapler. This technique is satisfactory for very low anterior resection.

  20. Structuralized box-trainer laparoscopic training significantly improves performance in complex virtual reality laparoscopic tasks.

    PubMed

    Laski, Dariusz; Stefaniak, Tomasz J; Makarewicz, Wojciech; Proczko, Monika; Gruca, Zbigniew; Sledziński, Zbigniew

    2012-03-01

    In the era of flowering minimally invasive surgical techniques there is a need for new methods of teaching surgery and supervision of progress in skills and expertise. Virtual and physical box-trainers seem especially fit for this purpose, and allow for improvement of proficiency required in laparoscopic surgery. The study included 34 students who completed the authors' laparoscopic training on physical train-boxes. Progress was monitored by accomplishment of 3 exercises: moving pellets from one place to another, excising and clipping. Analysed parameters included time needed to complete the exercise and right and left hand movement tracks. Students were asked to do assigned tasks prior to, in the middle and after the training. The duration of the course was 28 h in total. Significant shortening of the time to perform each exercise and reduction of the left hand track were achieved. The right hand track was shortened only in exercise number 1. Exercises in the laboratory setting should be regarded as an important element of the process of skills acquisition by a young surgeon. Virtual reality laparoscopic training seems to be a new, interesting educational tool, and at the same time allows for reliable control and assessment of progress.

  1. Use of the 5-mm Endoscopic Stapler for Ligation of Fistula in Laparoscopic-Assisted Repair of Anorectal Malformation.

    PubMed

    Slater, Bethany J; Kay, Saundra; Rothenberg, Steven S

    2018-02-15

    Laparoscopic anorectoplasty (LARRP) for the treatment of select anorectal malformations has gained popularity due to enhanced visualization of the fistula and the ability to place the rectum within the sphincter complex while minimizing division of muscles and the perineal incision. However, given the technical challenges and reported complications of ligation, a number of techniques have been described, including using clips, suture ligation, endoloops, or division without closure. We aimed to evaluate fistula closure and division for high imperforate anus using a 5-mm stapler (JustRight Surgical, Boulder, CO). A retrospective chart review was performed on patients who underwent LAARP for imperforate anus between March 2015 and December 2016. Four patients underwent LAARP with division of the fistula using the 5-mm stapler. The average age was 3.2 months and average weight was 4.5 kg. The location of the fistula was rectoprostatic in 3 cases and rectobladder neck in 1 case. There were no complications. Division of a fistula at or above the level of the prostate can safely and effectively be performed with the 5-mm stapler. The stapler allows for division flush with the urethra or bladder ergonomically and quickly.

  2. CLIPS: An expert system building tool

    NASA Technical Reports Server (NTRS)

    Riley, Gary

    1991-01-01

    The C Language Integrated Production System (CLIPS) is an expert system building tool, which provides a complete environment for the development and delivery of rule and/or object based expert systems. CLIPS was specifically designed to provide a low cost option for developing and deploying expert system applications across a wide range of hardware platforms. The commercial potential of CLIPS is vast. Currently, CLIPS is being used by over 3,300 individuals throughout the public and private sector. Because the CLIPS source code is readily available, numerous groups have used CLIPS as a basis for their own expert system tools. To date, three commercially available tools have been derived from CLIPS. In general, the development of CLIPS has helped to improve the ability to deliver expert system technology throughout the public and private sectors for a wide range of applications and diverse computing environments.

  3. Evaluation of color mapping algorithms in different color spaces

    NASA Astrophysics Data System (ADS)

    Bronner, Timothée.-Florian; Boitard, Ronan; Pourazad, Mahsa T.; Nasiopoulos, Panos; Ebrahimi, Touradj

    2016-09-01

    The color gamut supported by current commercial displays is only a subset of the full spectrum of colors visible by the human eye. In High-Definition (HD) television technology, the scope of the supported colors covers 35.9% of the full visible gamut. For comparison, Ultra High-Definition (UHD) television, which is currently being deployed on the market, extends this range to 75.8%. However, when reproducing content with a wider color gamut than that of a television, typically UHD content on HD television, some original color information may lie outside the reproduction capabilities of the television. Efficient gamut mapping techniques are required in order to fit the colors of any source content into the gamut of a given display. The goal of gamut mapping is to minimize the distortion, in terms of perceptual quality, when converting video from one color gamut to another. It is assumed that the efficiency of gamut mapping depends on the color space in which it is computed. In this article, we evaluate 14 gamut mapping techniques, 12 combinations of two projection methods across six color spaces as well as R'G'B' Clipping and wrong gamut interpretation. Objective results, using the CIEDE2000 metric, show that the R'G'B' Clipping is slightly outperformed by only one combination of color space and projection method. However, analysis of images shows that R'G'B' Clipping can result in loss of contrast in highly saturated images, greatly impairing the quality of the mapped image.

  4. HyperCLIPS: A HyperCard interface to CLIPS

    NASA Technical Reports Server (NTRS)

    Pickering, Brad; Hill, Randall W., Jr.

    1990-01-01

    HyperCLIPS combines the intuitive, interactive user interface of the Apple Macintosh(TM) with the powerful symbolic computation of an expert system interpreter. HyperCard(TM) is an excellent environment for quickly developing the front end of an application with buttons, dialogs, and pictures, while the CLIPS interpreter provides a powerful inference engine for complex problem solving and analysis. By integrating HyperCard and CLIPS the advantages and uses of both packages are made available for a wide range of uses: rapid prototyping of knowledge-based expert systems, interactive simulations of physical systems, and intelligent control of hypertext processes, to name a few. Interfacing HyperCard and CLIPS is natural. HyperCard was designed to be extended through the use of external commands (XCMDs), and CLIPS was designed to be embedded through the use of the I/O router facilities and callable interface routines. With the exception of some technical difficulties which will be discussed later, HyperCLIPS implements this interface in a straight forward manner, using the facilities provided. An XCMD called 'ClipsX' was added to HyperCard to give access to the CLIPS routines: clear, load, reset, and run. And an I/O router was added to CLIPS to handle the communication of data between CLIPS and HyperCard.

  5. Development of a new biodegradable operative clip made of a magnesium alloy: Evaluation of its safety and tolerability for canine cholecystectomy.

    PubMed

    Yoshida, Toshihiko; Fukumoto, Takumi; Urade, Takeshi; Kido, Masahiro; Toyama, Hirochika; Asari, Sadaki; Ajiki, Tetsuo; Ikeo, Naoko; Mukai, Toshiji; Ku, Yonson

    2017-06-01

    Operative clips used to ligate vessels in abdominal operation usually are made of titanium. They remain in the body permanently and form metallic artifacts in computed tomography images, which impair accurate diagnosis. Although biodegradable magnesium instruments have been developed in other fields, the physical properties necessary for operative clips differ from those of other instruments. We developed a biodegradable magnesium-zinc-calcium alloy clip with good biologic compatibility and enough clamping capability as an operative clip. In this study, we verified the safety and tolerability of this clip for use in canine cholecystectomy. Nine female beagles were used. We performed cholecystectomy and ligated the cystic duct by magnesium alloy or titanium clips. The chronologic change of clips and artifact formation were compared at 1, 4, 12, 18, and 24 weeks postoperative by computed tomography. The animals were killed at the end of the observation period, and the clips were removed to evaluate their biodegradability. We also evaluated their effect on the living body by blood biochemistry data. The magnesium alloy clip formed much fewer artifacts than the titanium clip, and it was almost absorbed at 6 months postoperative. There were no postoperative complications and no elevation of constituent elements such as magnesium, calcium, and zinc during the observation period in both groups. The novel magnesium alloy clip demonstrated sufficient sealing capability for the cystic duct and proper biodegradability in canine models. The magnesium alloy clip revealed much fewer metallic artifacts in CT than the conventional titanium clip. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. Quantitative analysis on electrooculography (EOG) for neurodegenerative disease

    NASA Astrophysics Data System (ADS)

    Liu, Chang-Chia; Chaovalitwongse, W. Art; Pardalos, Panos M.; Seref, Onur; Xanthopoulos, Petros; Sackellares, J. C.; Skidmore, Frank M.

    2007-11-01

    Many studies have documented abnormal horizontal and vertical eye movements in human neurodegenerative disease as well as during altered states of consciousness (including drowsiness and intoxication) in healthy adults. Eye movement measurement may play an important role measuring the progress of neurodegenerative diseases and state of alertness in healthy individuals. There are several techniques for measuring eye movement, Infrared detection technique (IR). Video-oculography (VOG), Scleral eye coil and EOG. Among those available recording techniques, EOG is a major source for monitoring the abnormal eye movement. In this real-time quantitative analysis study, the methods which can capture the characteristic of the eye movement were proposed to accurately categorize the state of neurodegenerative subjects. The EOG recordings were taken while 5 tested subjects were watching a short (>120 s) animation clip. In response to the animated clip the participants executed a number of eye movements, including vertical smooth pursued (SVP), horizontal smooth pursued (HVP) and random saccades (RS). Detection of abnormalities in ocular movement may improve our diagnosis and understanding a neurodegenerative disease and altered states of consciousness. A standard real-time quantitative analysis will improve detection and provide a better understanding of pathology in these disorders.

  7. [Peroperative risks in cerebral aneurysm surgery].

    PubMed

    Mustaki, J P; Bissonnette, B; Archer, D; Boulard, G; Ravussin, P

    1996-01-01

    The perioperative complications associated with cerebral aneurysm surgery require a specific anaesthetic management. Four major perioperative accidents are discussed in this review. The anaesthetic and surgical management in case of rebleeding subsequent to the re-rupture of the aneurysm is mainly prophylactic. It includes haemodynamic stability assurance, maintenance of mean arterial pressure (MAP) between 80-90 mmHg during stimulation of the patient such as endotracheal intubation, application of the skull-pin head-holder, incision, and craniotomy. The aneurysmal transmural pressure should be adequately maintained by avoiding an aggressive decrease of intracranial pressure. Once the skull is open, the brain must be kept slack in order to decrease pressure under the retractors and avoid the risks of stretching and tearing of the adjacent vessels. If, despite these precautions, the aneurysm ruptures again. MAP should be decreased to 60 mmHg and the brain rendered more slack, in order to allow direct clipping of the aneurysm, or temporary clipping of the adjacent vessels. The optimal agents in this situation are isoflurane (which decreases CMRO2), intravenous anaesthetic agents (inspite their negative inotropic effect, they may potentially protect the brain) and sodium nitroprusside. Vasospasm occurs usually between the 3rd and the 7th day after subarachnoid haemorrhage. It may be seen peroperatively. The optimal treatment, as well as prophylaxis, is moderate controlled hypertension (MAP > 100 mmHg), associated with hypervolaemia and haemodilution, the so-called triple H therapy, with strict control of the filling pressures. Other beneficial therapies are calcium antagonists (nimodipine and nicardipine), the removal of the blood accumulated around the brain and in the cisternae, and possibly local administration of papaverine. Abrupt MAP increases are controlled in order to maintain adequate aneurysmal transmural pressure. Beta-blockers, local anaesthetics administered locally or intravenously, a carefully titrated level of anaesthesia, a maintained volaemia play a protective role. Cerebral oedema is sometimes already present at the opening of the skull or may arise later, due to a high pressure under the retractors, to the surgical manipulations of the brain or to brain ischaemia subsequent to temporary clipping. Its treatment is aggressive, with intravenous agents, mannitol, deep hypocapnia and/or lumbar drainage. Prophylaxis, according to the "brain homeostasis concept", is the preferred method to avoid these four peroperative accidents. It includes normal blood volume, normoglycaemia, moderate hypocapnia, normotension, soft manipulation of the brain and optimal brain relaxation.

  8. Percussive Drill Test at JPL

    NASA Image and Video Library

    2018-05-17

    This video clip shows a test of a new percussive drilling technique at NASA's Jet Propulsion Laboratory in Pasadena, California. On May 19, NASA's Curiosity rover is scheduled to test percussive drilling on Mars for the first time since December 2016. The video clip was shot on March 28, 2018. It has been sped up by 50 times. Curiosity's drill was designed to pulverize rocks samples into powder, which can then be deposited into two chemistry laboratories carried inside of the rover. Curiosity's science team is eager to the rover using percussive drilling again; it will approach a clay-enriched area later this year that could shed new light on the history of water in Gale Crater. An animation is available at https://photojournal.jpl.nasa.gov/catalog/PIA22324

  9. Content-based video retrieval by example video clip

    NASA Astrophysics Data System (ADS)

    Dimitrova, Nevenka; Abdel-Mottaleb, Mohamed

    1997-01-01

    This paper presents a novel approach for video retrieval from a large archive of MPEG or Motion JPEG compressed video clips. We introduce a retrieval algorithm that takes a video clip as a query and searches the database for clips with similar contents. Video clips are characterized by a sequence of representative frame signatures, which are constructed from DC coefficients and motion information (`DC+M' signatures). The similarity between two video clips is determined by using their respective signatures. This method facilitates retrieval of clips for the purpose of video editing, broadcast news retrieval, or copyright violation detection.

  10. Assessment of construct validity of a virtual reality laparoscopy simulator.

    PubMed

    Rosenthal, Rachel; Gantert, Walter A; Hamel, Christian; Hahnloser, Dieter; Metzger, Juerg; Kocher, Thomas; Vogelbach, Peter; Scheidegger, Daniel; Oertli, Daniel; Clavien, Pierre-Alain

    2007-08-01

    The aim of this study was to assess whether virtual reality (VR) can discriminate between the skills of novices and intermediate-level laparoscopic surgical trainees (construct validity), and whether the simulator assessment correlates with an expert's evaluation of performance. Three hundred and seven (307) participants of the 19th-22nd Davos International Gastrointestinal Surgery Workshops performed the clip-and-cut task on the Xitact LS 500 VR simulator (Xitact S.A., Morges, Switzerland). According to their previous experience in laparoscopic surgery, participants were assigned to the basic course (BC) or the intermediate course (IC). Objective performance parameters recorded by the simulator were compared to the standardized assessment by the course instructors during laparoscopic pelvitrainer and conventional surgery exercises. IC participants performed significantly better on the VR simulator than BC participants for the task completion time as well as the economy of movement of the right instrument, not the left instrument. Participants with maximum scores in the pelvitrainer cholecystectomy task performed the VR trial significantly faster, compared to those who scored less. In the conventional surgery task, a significant difference between those who scored the maximum and those who scored less was found not only for task completion time, but also for economy of movement of the right instrument. VR simulation provides a valid assessment of psychomotor skills and some basic aspects of spatial skills in laparoscopic surgery. Furthermore, VR allows discrimination between trainees with different levels of experience in laparoscopic surgery establishing construct validity for the Xitact LS 500 clip-and-cut task. Virtual reality may become the gold standard to assess and monitor surgical skills in laparoscopic surgery.

  11. Construct validity of individual and summary performance metrics associated with a computer-based laparoscopic simulator.

    PubMed

    Rivard, Justin D; Vergis, Ashley S; Unger, Bertram J; Hardy, Krista M; Andrew, Chris G; Gillman, Lawrence M; Park, Jason

    2014-06-01

    Computer-based surgical simulators capture a multitude of metrics based on different aspects of performance, such as speed, accuracy, and movement efficiency. However, without rigorous assessment, it may be unclear whether all, some, or none of these metrics actually reflect technical skill, which can compromise educational efforts on these simulators. We assessed the construct validity of individual performance metrics on the LapVR simulator (Immersion Medical, San Jose, CA, USA) and used these data to create task-specific summary metrics. Medical students with no prior laparoscopic experience (novices, N = 12), junior surgical residents with some laparoscopic experience (intermediates, N = 12), and experienced surgeons (experts, N = 11) all completed three repetitions of four LapVR simulator tasks. The tasks included three basic skills (peg transfer, cutting, clipping) and one procedural skill (adhesiolysis). We selected 36 individual metrics on the four tasks that assessed six different aspects of performance, including speed, motion path length, respect for tissue, accuracy, task-specific errors, and successful task completion. Four of seven individual metrics assessed for peg transfer, six of ten metrics for cutting, four of nine metrics for clipping, and three of ten metrics for adhesiolysis discriminated between experience levels. Time and motion path length were significant on all four tasks. We used the validated individual metrics to create summary equations for each task, which successfully distinguished between the different experience levels. Educators should maintain some skepticism when reviewing the plethora of metrics captured by computer-based simulators, as some but not all are valid. We showed the construct validity of a limited number of individual metrics and developed summary metrics for the LapVR. The summary metrics provide a succinct way of assessing skill with a single metric for each task, but require further validation.

  12. Non-contrast 3D time-of-flight magnetic resonance angiography for visualization of intracranial aneurysms in patients with absolute contraindications to CT or MRI contrast.

    PubMed

    Yanamadala, Vijay; Sheth, Sameer A; Walcott, Brian P; Buchbinder, Bradley R; Buckley, Deidre; Ogilvy, Christopher S

    2013-08-01

    The preoperative evaluation of patients with intracranial aneurysms typically includes a contrast-enhanced vascular study, such as computed tomography angiography (CTA), magnetic resonance angiography (MRA), or digital subtraction angiography. However, there are numerous absolute and relative contraindications to the administration of imaging contrast agents, including pregnancy, severe contrast allergy, and renal insufficiency. Evaluation of patients with contrast contraindications thus presents a unique challenge. We identified three patients with absolute contrast contraindications who presented with intracranial aneurysms. One patient was pregnant, while the other two had previous severe anaphylactic reactions to iodinated contrast. Because of these contraindications to intravenous contrast, we performed non-contrast time-of-flight MRA with 3D reconstruction (TOF MRA with 3DR) with maximum intensity projections and volume renderings as part of the preoperative evaluation prior to successful open surgical clipping of the aneurysms. In the case of one paraclinoid aneurysm, a high-resolution non-contrast CT scan was also performed to assess the relationship of the aneurysm to the anterior clinoid process. TOF MRA with 3DR successfully identified the intracranial aneurysms and adequately depicted the surrounding microanatomy. Intraoperative findings were as predicted by the preoperative imaging studies. The aneurysms were successfully clip-obliterated, and the patients had uneventful post-operative courses. These cases demonstrate that non-contrast imaging is a viable modality to assess intracranial aneurysms as part of the surgical planning process in patients with contrast contraindications. TOF MRA with 3DR, in conjunction with high-resolution non-contrast CT when indicated, provides adequate visualization of the microanatomy of the aneurysm and surrounding structures. Copyright © 2013 Elsevier Ltd. All rights reserved.

  13. Blood blister-like aneurysms: single center experience and systematic literature review.

    PubMed

    Gonzalez, Ana Marcos; Narata, Ana Paula; Yilmaz, Hasan; Bijlenga, Philippe; Radovanovic, Ivan; Schaller, Karl; Lovblad, Karl-Olof; Pereira, Vitor Mendes

    2014-01-01

    Blood blister-like aneurysms (BBAs) are a controversial entity. They arise from non-branching sites on the supraclinoid internal carotid artery (ICA) and are suspected to originate from a dissection. Our aim is to describe the BBA cases seen in our center and to present a systematic review of the literature on BBAs. We analyzed the eleven cases of BBA admitted to our center from 2003 to 2012. We assessed the medical history, treatment modality (endovascular and/or surgery), complications and clinical outcome. The cohort included 8 women and 4 men with a mean age of 53.16 years. Treatment of the BBA consisted of stenting and coiling in 5 patients, stenting only in 4 patients, coiling and clipping in 1 patient, clipping only in 1 patient, and conservative treatment in 1 patient. A good outcome was found in 10 patients, as defined by a modified Rankin Scale (mRS) less than or equal to two at three months. A systematic review of the literature was performed, and 314 reported patients were found: 221 patients were treated with a primarily surgical approach, and 87 patients were treated with a primarily endovascular approach. A rescue or second treatment was required in 46 patients (21%). The overall estimated treatment morbidity rate was 17%, and the mortality rate was 15%. BBAs exhibit more aggressive behavior compared to saccular aneurysms, and more intra-operative complications occur with BBAs, independent of the treatment type offered. They are also significantly more likely to relapse and rebleed after treatment. Endovascular treatment offers a lower morbidity-mortality compared with surgical approaches. Multilayer flow-diverting stents appear to be a promising strategy. Copyright © 2013 The Authors. Published by Elsevier Ireland Ltd.. All rights reserved.

  14. Radiologic advantages of potential use of polymer plastic clips in neurosurgery.

    PubMed

    Delibegović, Samir

    2014-01-01

    Plastic clips are made of diamagnetic material and may result in fewer computed tomography (CT) and magnetic resonance artifacts than titanium clips. Considering that polymer plastic clips are increasingly being used in endoscopic surgery, our study examined the CT and magnetic resonance imaging (MRI) characteristics of plastic clips after application in the neurocranium and compared them with titanium clips. Craniotomy was performed on the heads of domestic pigs (Sus scrofa domestica), and, at an angle of 90°, a permanent Yasargil FT 746 T clip was placed in a frontobasal, interhemispheric position. A plastic polymer medium-large Hem-o-lok clip was placed in the same position into another animal. After this procedure, CT of the brain was performed using Siemens 16 slice, followed by an MRI scan, on Philips MRI, 1.5 Tesla. The CT and magnetic resonance scans were analyzed. On axial CT sections through the site of placement of titanium clips, dotted hyperdensity with a high value of Hounsfield units (HUI) of about 2800-3000 could be clearly seen. At the site where the plastic polymer clips were placed, discrete hyperdensity was observed, measuring 130-140 HUI. MRI of the brain in which titanium clips were used revealed a hypointensive T1W signal in the interhemispheric fissure, with a hypointensive T2W signal. On the other hand, upon examination of the MRI of the brain in which plastic clips were used, the T1W signal described above did not occur, and there was also no T2W signal, and no artifacts observed. The plastic clips are made of a diamagnetic, nonconductive material that results in fewer CT and MRI artifacts than titanium clips. Copyright © 2014 Elsevier Inc. All rights reserved.

  15. Single-incision laparoscopic cholecystectomy: a systematic review of methodology and outcomes.

    PubMed

    Yamazaki, Masato; Yasuda, Hideki; Koda, Keiji

    2015-05-01

    (1) To survey the dissemination of SILC; (2) to determine which SILC method has become mainstream; (3) to determine whether the characteristic complications vary according to the type of procedure. An electronic search of PubMed, Databases@Ovid, and SciVerse Scopus between 2003/01/01 and 2012/12/31 was performed. The peak number of annually published articles was 70 in 2011. The most common procedures were single skin incision, the use of a SILS Port(®), suture suspension and a 5-mm oblique scope. The intraoperative complications rate was 1.69 %. Postoperative complications occurred in 213/5283 cases. According to the surgical procedure, five factors (approach; P = 0.0017, gallbladder anchorage; P < 0.001, size; P = 0.049 and type; P < 0.001 of the scope, and size of the clip applier; P = 0.074) significantly affected the incidence of wound infection. The incidence of wound seroma/bleeding was significantly influenced by gallbladder anchorage (P = 0.009), the use of curved/articulated instruments (P = 0.048), and the diameter of the clip applier (P < 0.001). To determine the best operative procedure for SILC, an analysis of uniform operative procedures is needed.

  16. In vivo measurement of hemodynamic information in stenosed rat blood vessels using X-ray PIV

    NASA Astrophysics Data System (ADS)

    Park, Hanwook; Park, Jun Hong; Lee, Sang Joon

    2016-11-01

    Measurements of the hemodynamic information of blood flows, especially wall shear stress (WSS), in animal models with circulatory vascular diseases (CVDs) are important to understand the pathological mechanism of CVDs. In this study, X-ray particle image velocimetry (PIV) with high spatial resolution was applied to obtain velocity field information in stenosed blood vessels with high WSS. 3D clips fabricated with a 3D printer were applied to the abdominal aorta of a rat cadaver to induce artificial stenosis in the real blood vessel of an animal model. The velocity and WSS information of blood flows in the stenosed vessel were obtained and compared at various stenosis severities. In vivo measurement was also conducted by fastening a stenotic clip on a live rat model through surgical intervention to reduce the flow rate to match the limited temporal resolution of the present X-ray PIV system. Further improvement of the temporal resolution of the system might be able to provide in vivo measurements of hemodynamic information from animal disease models under physiological conditions. The present results would be helpful for understanding the relation between hemodynamic characteristics and the pathological mechanism in animal CVD models.

  17. [Cerebral aneurysms complicating bacterial endocarditis. Seven cases (author's transl)].

    PubMed

    Pecker, J; Vallée, B; Camuzet, J P; Faivre, J; Javalet, A

    The authors report seven cases of cerebral aneurysms complicating bacterial endocarditis. The evolution was good in three cases, two of which without sequelae. The bacteries involved were staphylococcus, streptococcus, and enterobacter. The cardiopathy was mitral in four cases. Two patients presented an isolated focal neurological impairment, while the other five presented a severe coma either isolated (one case) or associated with focal neurological deficits (four cases). An intracerebral hematoma was diagnosed in five cases (four died). Only one patient was not operated. The surgical treatment was as follows: one carotid ligation (good result), two evacuations of intracerebral hematomas (both died), two evacuations of intracerebral hematomas with clipping of the aneurysms (one died, one had a fair result in despite of residual hemiplegia), one clipping of aneurysm (good result). Repeated cerebral angiographies should be systematically performed in cases of bacterial endocarditis in order to disclose and follow up cerebral aneurysms which may occur in this condition. Except in cases of emergency, surgery should be differed, in particular, in cases of proximal or multiple aneurysms. Aneurysms of the peripheral cortical arteries are more accessible to treatment and may be operated in the acute phase.

  18. Ratings for emotion film clips.

    PubMed

    Gabert-Quillen, Crystal A; Bartolini, Ellen E; Abravanel, Benjamin T; Sanislow, Charles A

    2015-09-01

    Film clips are widely utilized to elicit emotion in a variety of research studies. Normative ratings for scenes selected for these purposes support the idea that selected clips correspond to the intended target emotion, but studies reporting normative ratings are limited. Using an ethnically diverse sample of college undergraduates, selected clips were rated for intensity, discreteness, valence, and arousal. Variables hypothesized to affect the perception of stimuli (i.e., gender, race-ethnicity, and familiarity) were also examined. Our analyses generally indicated that males reacted strongly to positively valenced film clips, whereas females reacted more strongly to negatively valenced film clips. Caucasian participants tended to react more strongly to the film clips, and we found some variation by race-ethnicity across target emotions. Finally, familiarity with the films tended to produce higher ratings for positively valenced film clips, and lower ratings for negatively valenced film clips. These findings provide normative ratings for a useful set of film clips for the study of emotion, and they underscore factors to be considered in research that utilizes scenes from film for emotion elicitation.

  19. Authoring Data-Driven Videos with DataClips.

    PubMed

    Amini, Fereshteh; Riche, Nathalie Henry; Lee, Bongshin; Monroy-Hernandez, Andres; Irani, Pourang

    2017-01-01

    Data videos, or short data-driven motion graphics, are an increasingly popular medium for storytelling. However, creating data videos is difficult as it involves pulling together a unique combination of skills. We introduce DataClips, an authoring tool aimed at lowering the barriers to crafting data videos. DataClips allows non-experts to assemble data-driven "clips" together to form longer sequences. We constructed the library of data clips by analyzing the composition of over 70 data videos produced by reputable sources such as The New York Times and The Guardian. We demonstrate that DataClips can reproduce over 90% of our data videos corpus. We also report on a qualitative study comparing the authoring process and outcome achieved by (1) non-experts using DataClips, and (2) experts using Adobe Illustrator and After Effects to create data-driven clips. Results indicated that non-experts are able to learn and use DataClips with a short training period. In the span of one hour, they were able to produce more videos than experts using a professional editing tool, and their clips were rated similarly by an independent audience.

  20. Proposal for a CLIPS software library

    NASA Technical Reports Server (NTRS)

    Porter, Ken

    1991-01-01

    This paper is a proposal to create a software library for the C Language Integrated Production System (CLIPS) expert system shell developed by NASA. Many innovative ideas for extending CLIPS were presented at the First CLIPS Users Conference, including useful user and database interfaces. CLIPS developers would benefit from a software library of reusable code. The CLIPS Users Group should establish a software library-- a course of action to make that happen is proposed. Open discussion to revise this library concept is essential, since only a group effort is likely to succeed. A response form intended to solicit opinions and support from the CLIPS community is included.

  1. Biocompatibility of Plastic Clip in Neurocranium - Experimental Study on Dogs.

    PubMed

    Delibegovic, Samir; Dizdarevic, Kemal; Cickusic, Elmir; Katica, Muhamed; Obhodjas, Muamer; Ocus, Muhamed

    2016-01-01

    A potential advantage of the use of the plastic clips in neurosurgery is their property of causing fewer artifacts than titanium clips as assessed by computed tomography and magnetic resonance scans. The biocompatibility of plastic clips was demonstrated in the peritoneal cavity, but their behavior in the neurocranium is not known. Twelve aggressive stray dogs designated for euthanasia were taken for this experimental study. The animals were divided into two groups. In all cases, after anesthesia, a craniotomy was performed, and after opening the dura, a proximal part titanium clip was placed on the isolated superficial Sylvian vein (a permanent Yasargil FT 746 T clip at a 90° angle, while a plastic Hem-o-lok clip ML was placed on another part of the vein). The first group of animals was sacrificed on the 7 < sup > th < /sup > postoperative day and the second group on the 60 < sup > th < /sup > postoperative day. Samples of tissue around the clips were taken for a histopathological evaluation. The plastic clip caused a more intensive tissue reaction than the titanium clip on the 7 < sup > th < /sup > postoperative day, but there was no statistical difference. Even on the 60 < sup > th < /sup > postoperative day there was no significant difference in tissue reaction between the titanium and plastic clips. These preliminary results confirm the possibility for the use of plastic clips in neurosurgery. Before their use in human neurosurgery, further studies are needed to investigate the long-term effects of the presence of plastic clips in the neurocranium, as well as studies of the aneurysmal model.

  2. Effects of core body temperature on changes in spinal somatosensory-evoked potential in acute spinal cord compression injury: an experimental study in the rat.

    PubMed

    Jou, I M

    2000-08-01

    Acute spinal cord injury was induced by a clip compression model in rats to approximate spinal cord injury encountered in spinal surgery. Spinal somatosensory-evoked potential neuromonitoring was used to study the electrophysiologic change. To compare and correlate changes in evoked potential after acute compression at different core temperatures with postoperative neurologic function and histologic change, to evaluate current intraoperative neuromonitoring warning criteria for neural damage, and to confirm the protective effect of hypothermia in acute spinal cord compression injury by electrophysiologic, histologic, and clinical observation. With the increase in aggressive correction of spinal deformities, and the invasiveness of surgical instruments, the incidence of neurologic complication appears to have increased despite the availability of sensitive intraoperative neuromonitoring techniques designed to alert surgeons to impending neural damage. Many reasons have been given for the frequent failures of neuromonitoring, but the influence of temperature-a very important and frequently encountered factor-on evoked potential has not been well documented. Specifically, decrease in amplitude and elongation of latency seem not to have been sufficiently taken into account when intraoperative neuromonitoring levels were interpreted and when acceptable intraoperative warning criteria were determined. Experimental acute spinal cord injury was induced in rats by clip compression for two different intervals and at three different core temperatures. Spinal somatosensory-evoked potential, elicited by stimulating the median nerve and recorded from the cervical interspinous C2-C3, was monitored immediately before and after compression, and at 15-minute intervals for 1 hour. Spinal somatosensory-evoked potential change is almost parallel to temperature-based amplitude reduction and latency elongation. Significant neurologic damage induced by acute compression of the cervical spinal cord produced a degree of effect on the amplitude of spinal somatosensory-evoked potential in normothermic conditions that differed from the effect in moderately hypothermic conditions. Using the same electromonitoring criteria,moderately hypothermic groups showed a significantly higher false-negative rate statistically (35%) than normothermic groups (10%). Systemic cooling may protect against the detrimental effects of aggressive spinal surgical procedures. There is still not enough published information available to establish statistically and ethically acceptable intraoperative neuromonitoring warning and intervention criteria conclusively. Therefore, an urgent need exists for further investigation. Although a reduction of more than 50% in evoked potential still seems acceptable as an indicator of impending neural function loss, maintenance of more than 50% of baseline evoked potential is no guarantee of normal postoperative neural function, especially at lower than normal temperatures.

  3. Fuzzy expert systems using CLIPS

    NASA Technical Reports Server (NTRS)

    Le, Thach C.

    1994-01-01

    This paper describes a CLIPS-based fuzzy expert system development environment called FCLIPS and illustrates its application to the simulated cart-pole balancing problem. FCLIPS is a straightforward extension of CLIPS without any alteration to the CLIPS internal structures. It makes use of the object-oriented and module features in CLIPS version 6.0 for the implementation of fuzzy logic concepts. Systems of varying degrees of mixed Boolean and fuzzy rules can be implemented in CLIPS. Design and implementation issues of FCLIPS will also be discussed.

  4. Restoration of clipped seismic waveforms using projection onto convex sets method

    PubMed Central

    Zhang, Jinhai; Hao, Jinlai; Zhao, Xu; Wang, Shuqin; Zhao, Lianfeng; Wang, Weimin; Yao, Zhenxing

    2016-01-01

    The seismic waveforms would be clipped when the amplitude exceeds the upper-limit dynamic range of seismometer. Clipped waveforms are typically assumed not useful and seldom used in waveform-based research. Here, we assume the clipped components of the waveform share the same frequency content with the un-clipped components. We leverage this similarity to convert clipped waveforms to true waveforms by iteratively reconstructing the frequency spectrum using the projection onto convex sets method. Using artificially clipped data we find that statistically the restoration error is ~1% and ~5% when clipped at 70% and 40% peak amplitude, respectively. We verify our method using real data recorded at co-located seismometers that have different gain controls, one set to record large amplitudes on scale and the other set to record low amplitudes on scale. Using our restoration method we recover 87 out of 93 clipped broadband records from the 2013 Mw6.6 Lushan earthquake. Estimating that we recover 20 clipped waveforms for each M5.0+ earthquake, so for the ~1,500 M5.0+ events that occur each year we could restore ~30,000 clipped waveforms each year, which would greatly enhance useable waveform data archives. These restored waveform data would also improve the azimuthal station coverage and spatial footprint. PMID:27966618

  5. Taxonomic and Functional Responses of Soil Microbial Communities to Annual Removal of Aboveground Plant Biomass

    PubMed Central

    Guo, Xue; Zhou, Xishu; Hale, Lauren; Yuan, Mengting; Feng, Jiajie; Ning, Daliang; Shi, Zhou; Qin, Yujia; Liu, Feifei; Wu, Liyou; He, Zhili; Van Nostrand, Joy D.; Liu, Xueduan; Luo, Yiqi; Tiedje, James M.; Zhou, Jizhong

    2018-01-01

    Clipping, removal of aboveground plant biomass, is an important issue in grassland ecology. However, few studies have focused on the effect of clipping on belowground microbial communities. Using integrated metagenomic technologies, we examined the taxonomic and functional responses of soil microbial communities to annual clipping (2010–2014) in a grassland ecosystem of the Great Plains of North America. Our results indicated that clipping significantly (P < 0.05) increased root and microbial respiration rates. Annual temporal variation within the microbial communities was much greater than the significant changes introduced by clipping, but cumulative effects of clipping were still observed in the long-term scale. The abundances of some bacterial and fungal lineages including Actinobacteria and Bacteroidetes were significantly (P < 0.05) changed by clipping. Clipping significantly (P < 0.05) increased the abundances of labile carbon (C) degrading genes. More importantly, the abundances of recalcitrant C degrading genes were consistently and significantly (P < 0.05) increased by clipping in the last 2 years, which could accelerate recalcitrant C degradation and weaken long-term soil carbon stability. Furthermore, genes involved in nutrient-cycling processes including nitrogen cycling and phosphorus utilization were also significantly increased by clipping. The shifts of microbial communities were significantly correlated with soil respiration and plant productivity. Intriguingly, clipping effects on microbial function may be highly regulated by precipitation at the interannual scale. Altogether, our results illustrated the potential of soil microbial communities for increased soil organic matter decomposition under clipping land-use practices. PMID:29904372

  6. It is time for a better clip applier - 3 mm, percutaneous, non-crushing and locking.

    PubMed

    Yuval, Jonathan B; Weiss, Daniel J; Paz, Adrian; Bachar, Yehuda; Brodie, Ronit; Shapira, Yinon; Mintz, Yoav

    2017-10-06

    Since the advent of laparoscopy there have been attempts to minimize abdominal wall incisions. For this purpose smaller instruments have been produced. Our aim was to develop the first 3 mm percutaneous clip applier and to make it better than the standard clips of today. The ClipTip clip is made of Nitinol and has a crocodile shaped jaws, which when apposed effectively seal vessels. The shaft operates as a retractable needle permitting percutaneous insertion. Closing, reopening and reclosing is possible. The physical properties of the device were compared to three commercially available clip appliers. Surgeries were performed on porcine animals by experienced surgeons. In comparison to available clips, the superiority of the ClipTip is a combination of wide effective length alongside the ability to withstand strong forces. In live animal studies the Cliptip was inserted into the peritoneal cavity without any injuries. Vessels were ligated successfully and no clip dislodgement or leakage occurred. We developed the next generation clip applier with better properties. Advantages include its length, the needleoscopic caliber, non-crushing effect, locking mechanism and wide aperture. The device has performed safely and effectively in pre-clinical tests. Further studies are planned in humans.

  7. Persistence in and Release of 2,4-D and Azoxystrobin from Turfgrass Clippings.

    PubMed

    Jeffries, Matthew D; Yelverton, Fred H; Ahmed, Khalied A; Gannon, Travis W

    2016-11-01

    Research has shown that pesticide residue in clippings from previously treated turfgrass may become bioavailable as grass decomposes, adversely affecting off-target organisms. We conducted a field study to quantify 2,4-D (2,4-dichlorophenoxyacetic acid) and azoxystrobin (methyl(E)-2-{2[6-(2-cyanophenoxy)pyrmidin-4-yloxy]phenyl}-3-methoxyacrylate) residues in turfgrass clippings collected from hybrid bermudagrass [ (L.) Pers. × Burtt-Davy], tall fescue [ (Schreb.) S.J. Darbyshire], and zoysiagrass ( Steud.). A subsequent greenhouse experiment was conducted to measure pesticide release from clippings into water. 2,4-D (1.6 kg a.i. ha) and azoxystrobin (0.6 kg a.i. ha) were applied to field plots at 32, 16, 8, 4, 2, 1, or 0 d before collection of the clippings. Clippings were collected from each experimental unit to quantify pesticide release from clippings into water. Both 2,4-D and azoxystrobin were detected when turfgrass was treated over the 32-d experimental period, suggesting that clipping management should be implemented for an extended period of time after application. Pesticide residue was detected in all water samples collected, confirming 2,4-D and azoxystrobin release from turfgrass clippings; however, pesticide release varied between compounds. Two days after clippings were incorporated in water, 39 and 10% of 2,4-D and azoxystrobin were released from clippings, respectively. Our research supports the currently recommended practice of returning clippings to the turfgrass stand when mowing because removal of 2,4-D and azoxystrobin in clippings may reduce pest control and cause adverse off-target impacts. Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.

  8. Minimally invasive surgical technique for tethered surgical drains

    PubMed Central

    Hess, Shane R; Satpathy, Jibanananda; Waligora, Andrew C; Ugwu-Oju, Obinna

    2017-01-01

    A feared complication of temporary surgical drain placement is from the technical error of accidentally suturing the surgical drain into the wound. Postoperative discovery of a tethered drain can frequently necessitate return to the operating room if it cannot be successfully removed with nonoperative techniques. Formal wound exploration increases anesthesia and infection risk as well as cost and is best avoided if possible. We present a minimally invasive surgical technique that can avoid the morbidity associated with a full surgical wound exploration to remove a tethered drain when other nonoperative techniques fail. PMID:28400669

  9. Aneurysmal subarachnoid hemorrhage with concomitant posterior communicating artery fenestration.

    PubMed

    Weiner, Gregory M; Grandhi, Ramesh; Zwagerman, Nathan T; Agarwal, Nitin; Friedlander, Robert M

    2015-02-01

    Fenestrations of the posterior communicating artery (PCoA) are extremely rare. Associated aneurysms have only been documented three times in the literature, and none associated with a subarachnoid hemorrhage. We describe a 52-year-old female who presented with a subarachnoid hemorrhage secondary to a ruptured saccular aneurysm at the proximal limb of a fenestrated right PCoA. The patient was also found to have bilateral middle cerebral artery (MCA) aneurysms. Surgical management included surmising the etiology of the subarachnoid hemorrhage with subsequent clipping of both the right PCoA and MCA aneurysm. The potential embryological mechanisms leading to a PCoA fenestration are discussed.

  10. Intracranial aneurysm and arachnoid cyst: just a coincidence? A case report.

    PubMed

    Aguiar, Guilherme Brasileiro de; Santos, Rafael Gomes Dos; Paiva, Aline Lariessy Campos; Silva, João Miguel de Almeida; Silva, Rafael Carlos da; Veiga, José Carlos Esteves

    2017-12-18

    Presence of an arachnoid cyst and a non-ruptured intracystic brain aneurysm is extremely rare. The aim of this paper was to describe a case of a patient with an arachnoid cyst and a non-ruptured aneurysm inside it. Clinical, surgical and radiological data were analyzed and the literature was reviewed. A patient complained of chronic headache. She was diagnosed as having a temporal arachnoid cyst and a non-ruptured middle cerebral artery aneurysm inside it. Surgery was performed to clip the aneurysm and fenestrate the cyst. This report raises awareness about the importance of intracranial vascular investigation in patients with arachnoid cysts and brain hemorrhage.

  11. Quantifying the real-world cost saving from using surgical adjuncts to prevent complications during cataract surgery.

    PubMed

    Jamison, Aaron; Benjamin, Larry; Lockington, David

    2018-06-06

    Surgical adjuncts in cataract surgery are often perceived as sometimes necessary, always expensive, particularly in the "lean" cost-saving era. However, prevention of a surgical complication, rather than subsequent management, should always be the preferred strategy. We wished to model real-world costs associated with surgical adjuncts use and test the maxim for cataract surgery-"if you think of it, use it". We compared UK list prices for equipment and related costs of preventing vitreous loss (VL) via use of surgical adjuncts vs its subsequent management in a hypothetical cataract surgery scenario of a white swollen cataract with a moderately dilated pupil. The original surgery costs for the "cautious with adjuncts, no complications" approach was £943.54, including adjuncts costing £137.47. In the "minimalist, no adjunct" scenario, management of VL using the Anterior Vitrectomy Kit cost £142.45, and additional management and follow-up costs resulted in total cost of £1178.20 (£234.66 (25%) more expensive). If left aphakic, an additional operation for secondary iris clip IOL insertion and further follow-up to address the impact of the complication ultimately cost £2124.67 overall. An additional initial spend on surgical adjuncts of £137.47 could potentially prevent £1293.60 (9× increase) in direct costs in this scenario. Through simple scenario modelling, we have demonstrated the cost benefits provided by the use of precautionary surgical adjuncts during cataract surgery. VL costs significantly more in terms of complication management and follow-up. This supports the cataract surgeon's maxim-"if you think of it, use it".

  12. Retrograde suction decompression of a large internal carotid aneurysm using a balloon guide catheter combined with a blood-returning circuit and STA-MCA bypass: a technical note.

    PubMed

    Matano, Fumihiro; Mizunari, Takayuki; Kominami, Shushi; Suzuki, Masanori; Fujiki, Yu; Kubota, Asami; Kobayashi, Shiro; Murai, Yasuo; Morita, Akio

    2017-04-01

    It is difficult to treat large internal carotid aneurysms with simple surgical clipping. Here, we present a retrograde suction decompression (RSD) procedure for large internal carotid aneurysms using a balloon guide catheter combined with a blood-returning circuit and a superficial temporal artery to middle cerebral artery (STA-MCA) bypass.All patients underwent an STA-MCA bypass before the temporary occlusion of the internal carotid artery (ICA). A 6-French sheath was inserted into the common carotid artery (CCA), and a 6-French Patrive balloon catheter was placed into the ICA 5 cm past the bifurcation. Aneurysm exposure was obtained; temporary clips were placed on the proximal M1, A1, and posterior communicating (Pcom) segments; and an extension tube was then connected to the balloon catheter. A three-way stopcock was placed, and aspiration was performed through the device to collapse the aneurysm. The aspirated blood was returned to a venous line with an added heparin to prevent anemia after aspiration. During the decompression, the blood flow to the cortical area was supplied through the STA-MCA bypass. After the aneurysm collapse, the surgeon carefully dissected the perforating artery from the aneurysm dome or neck, and permanent clips were then placed on the aneurysm neck. Our procedure has several advantages, such as STA-MCA bypass without external carotid artery occlusion for preventing ischemic complications of the cortical area, anemia may be avoided because of the return of the aspirated blood, and a hybrid operation room is not required to perform this method.

  13. Posterior Mandibular Ridge Resorption Associated with Different Retentive Systems for Overdentures: A 7-Year Retrospective Preliminary Study.

    PubMed

    Elsyad, Moustafa Abdou; Mohamed, Shahinaz Sayed; Shawky, Ahmad Fathalla

    This retrospective study compared posterior mandibular residual ridge resorption with two different retentive mechanisms for overdentures after 7 years. A convenience sample of 18 edentulous men was assigned to one of two equal groups. Two implants were placed in the mandibular canine areas for each patient using the conventional two-stage surgical protocol, and the implants were splinted with a round bar 3 months later. New mandibular overdentures were then connected to the bars with clips (clip-retained overdentures, CR group) or resilient liners (resilient liner-retained overdentures, RR group). Posterior mandibular ridge resorption (PMRR) was recorded using proportional measurements and posterior area index (PAI) on panoramic radiographs taken immediately after overdenture insertion (T 0 ) and 7 years later (T 7 ). A linear regression model was used to verify the relationship between PAI and the following considerations: attachment type, age, initial mandibular ridge height, period of mandibular edentulism, number of previously worn dentures, and relining events. After 7 years, the RR group demonstrated a significantly (P = .014) higher change in PAI (0.11 ± 0.02) than the CR group (0.06 ± 0.04). The average PMRR for each mm of posterior mandibular ridge was 0.79 mm (0.11 mm/year) in the CR group and 1.4 mm (0.2 mm/year) in the RR group. Attachment type, initial mandibular ridge height, and relining times were significantly correlated with change in the PAI (P = .004, P = .035, and P = .045, respectively). Within the limitations of this preliminary study's design, it was observed that following a 7-year period of use, resilient liner attachments for bar/implant-retained overdentures appear to be associated with greater posterior mandibular ridge resorption when compared to clip attachments.

  14. Endoscopic treatment and risk factors of postoperative anastomotic bleeding after gastrectomy for gastric cancer.

    PubMed

    Kim, Ki-Han; Kim, Min-Chan; Jung, Ghap-Joong; Jang, Jin-Seok; Choi, Seok-Ryeol

    2012-01-01

    Anastomotic leakage, bleeding, and stricture are major complications after gastrectomy. Of these complications, postoperative anastomotic bleeding is relatively rare, but lethal if not treated immediately. Of 2031 patients with gastric cancer who underwent radical gastrectomy (R0 resection) between January 2002 and December 2010, postoperative anastomotic bleeding was observed in 7 patients. The clinicopathological features, postoperative outcomes such as surgical procedures, bleeding sites and, methods used to achieve hemostasis, and the risk factors of anastomotic bleeding of these 7 patients were analyzed. Of the 2031 patients, 1613 and 418 underwent distal and total gastrectomy, respectively. The bleeding sites were as follows: Billroth-I anastomosis using a circular stapler (n = 1), Billroth-II anastomosis by manual suture (n = 5), and esophagojejunostomy using a circular stapler (n = 1). All patients were treated with endoscopic clipping or epinephrine injection. There was no further endoscopic intervention or reoperation for anastomotic bleeding. Postoperative anastomotic bleeding is an infrequent but potentially life-threatening complication. Scrupulous surgical procedures are essential for the prevention of postoperative bleeding, and endoscopy was useful for both the confirmation of bleeding and therapeutic intervention. Copyright © 2012 Surgical Associates Ltd. All rights reserved.

  15. Laparoscopic sterilization with the spring clip: instrumentation development and current clinical experience.

    PubMed

    Hulka, J F; Omran, K; Lieberman, B A; Gordon, A G

    1979-12-15

    Since the original spring clip sterilization studies were reported, a number of clinically important modifications to the spring clip and applicator have been developed. The spring-loaded clip, manufactured by Richard Wolf Medical Instruments Corporation of Chicago, Illinois, and Rocket of London, Inc., London, England, and New York, New York can be applied with either a one- or two-incision applicator and the clips and applicators currently available incorporate improvements to the original prototypes in design, manufacture, and quality control. The two-incision applicator is associated with significantly fewer misapplications and the high pregnancy rates reported with the original clip and applicator have not occurred with the current designs. Comparative studies between the clip and band have revealed less operative bleeding and pain associated with the clip. The method is appropriate to all women requesting sterilization but especially to those in the younger age group who may subsequently request reversal because of divorce and remarriage.

  16. An object oriented extension to CLIPS

    NASA Technical Reports Server (NTRS)

    Sobkowicz, Clifford

    1990-01-01

    A presentation of software sub-system developed to augment C Language Production Systems (CLIPS) with facilities for object oriented Knowledge representation. Functions are provided to define classes, instantiate objects, access attributes, and assert object related facts. This extension is implemented via the CLIPS user function interface and does not require modification of any CLIPS code. It does rely on internal CLIPS functions for memory management and symbol representation.

  17. New concept of 3D printed bone clip (polylactic acid/hydroxyapatite/silk composite) for internal fixation of bone fractures.

    PubMed

    Yeon, Yeung Kyu; Park, Hae Sang; Lee, Jung Min; Lee, Ji Seung; Lee, Young Jin; Sultan, Md Tipu; Seo, Ye Bin; Lee, Ok Joo; Kim, Soon Hee; Park, Chan Hum

    Open reduction with internal fixation is commonly used for the treatment of bone fractures. However, postoperative infection associated with internal fixation devices (intramedullary nails, plates, and screws) remains a significant complication, and it is technically difficult to fix multiple fragmented bony fractures using internal fixation devices. In addition, drilling in the bone to install devices can lead to secondary fracture, bone necrosis associated with postoperative infection. In this study, we developed bone clip type internal fixation device using three- dimensional (3D) printing technology. Standard 3D model of the bone clip was generated based on computed tomography (CT) scan of the femur in the rat. Polylacticacid (PLA), hydroxyapatite (HA), and silk were used for bone clip material. The purpose of this study was to characterize 3D printed PLA, PLA/HA, and PLA/HA/Silk composite bone clip and evaluate the feasibility of these bone clips as an internal fixation device. Based on the results, PLA/HA/Silk composite bone clip showed similar mechanical property, and superior biocompatibility compared to other types of the bone clip. PLA/HA/Silk composite bone clip demonstrated excellent alignment of the bony segments across the femur fracture site with well-positioned bone clip in an animal study. Our 3D printed bone clips have several advantages: (1) relatively noninvasive (drilling in the bone is not necessary), (2) patient-specific design (3) mechanically stable device, and (4) it provides high biocompatibility. Therefore, we suggest that our 3D printed PLA/HA/Silk composite bone clip is a possible internal fixation device.

  18. Third CLIPS Conference Proceedings, volume 2

    NASA Technical Reports Server (NTRS)

    Riley, Gary (Editor)

    1994-01-01

    Expert systems are computer programs which emulate human expertise in well defined problem domains. The C Language Integrated Production System (CLIPS) is an expert system building tool, developed at the Johnson Space Center, which provides a complete environment for the development and delivery of rule and/or object based expert systems. CLIPS was specifically designed to provide a low cost option for developing and deploying expert system applications across a wide range of hardware platforms. The development of CLIPS has helped to improve the ability to deliver expert system technology throughout the public and private sectors for a wide range of applications and diverse computing environments. The Third Conference on CLIPS provided a forum for CLIPS users to present and discuss papers relating to CLIPS applications, uses, and extensions.

  19. PAPR reduction in CO-OFDM systems using IPTS and modified clipping and filtering

    NASA Astrophysics Data System (ADS)

    Tong, Zheng-rong; Hu, Ya-nong; Zhang, Wei-hua

    2018-05-01

    Aiming at the problem of the peak to average power ratio ( PAPR) in coherent optical orthogonal frequency division multiplexing (CO-OFDM), a hybrid PAPR reduction technique of the CO-OFDM system by combining iterative partial transmit sequence (IPTS) scheme with modified clipping and filtering (MCF) is proposed. The simulation results show that at the complementary cumulative distribution function ( CCDF) of 10-4, the PAPR of proposed scheme is optimized by 1.86 dB and 2.13 dB compared with those of IPTS and CF schemes, respectively. Meanwhile, when the bit error rate ( BER) is 10-3, the optical signal to noise ratio ( OSNR) are optimized by 1.57 dB and 0.66 dB compared with those of CF and IPTS-CF schemes, respectively.

  20. MIRO: A debugging tool for CLIPS incorporating historical Rete networks

    NASA Technical Reports Server (NTRS)

    Tuttle, Sharon M.; Eick, Christoph F.

    1994-01-01

    At the last CLIPS conference, we discussed our ideas for adding a temporal dimension to the Rete network used to implement CLIPS. The resulting historical Rete network could then be used to store 'historical' information about a run of a CLIPS program, to aid in debugging. MIRO, a debugging tool for CLIPS built on top of CLIPS, incorporates such a historical Rete network and uses it to support its prototype question-answering capability. By enabling CLIPS users to directly ask debugging-related questions about the history of a program run, we hope to reduce the amount of single-stepping and program tracing required to debug a CLIPS program. In this paper, we briefly describe MIRO's architecture and implementation, and the current question-types that MIRO supports. These question-types are further illustrated using an example, and the benefits of the debugging tool are discussed. We also present empirical results that measure the run-time and partial storage overhead of MIRO, and discuss how MIRO may also be used to study various efficiency aspects of CLIPS programs.

  1. Ex vivo hydrodynamics after central and paracommissural edge-to-edge technique: A further step toward transcatheter tricuspid repair?

    PubMed

    Stock, Sina; Bohm, Heidemarie; Scharfschwerdt, Michael; Richardt, Doreen; Meyer-Saraei, Roza; Tsvelodub, Stanislav; Sievers, Hans-Hinrich

    2018-03-01

    Transcatheter approaches in heart valve disease became tremendously important and are currently established in the aortic position, but transcatheter tricuspid repair is still in its beginning and remains challenging. Replicating the surgical edge-to-edge technique, for example, with the MitraClip System (Abbott Vascular, Santa Clara, Calif), represents a promising option and has been reported successfully in small numbers of cases. However, up to now, few data considering the edge-to-edge technique as a transcatheter approach are available. This study aims to determine the ex vivo hydrodynamics after the central and paracommissural edge-to-edge technique in different pathologies. Because of basal or apical dislocation of papillary muscles, leaflet prolapse or tethering was simulated in porcine tricuspid valves mounted on a flexible holding device. Central and paracommissural edge-to-edge techniques were evaluated successively in these pathologies. Regurgitant volume and mean transvalvular gradient were determined in a pulse duplicator. In this ex vivo model, the isolated edge-to-edge technique reduced tricuspid regurgitation. In the prolapse model, regurgitant volume decreased significantly after central edge-to-edge technique (from 49.4 ± 13.6 mL/stroke to 39.3 ± 14.1 mL/stroke). In the tethering model, both the central and the paracommissural edge-to-edge techniques led to a significant decrease (from 48.7 ± 13.9 to 43.6 ± 15.6 and to 41.1 ± 13.8 mL/stroke). In all cases, the reduction of regurgitant volume was achieved at the cost of significantly increased mean transvalvular gradient. This study provides a reduction of tricuspid regurgitation after the edge-to-edge technique in the specific experimental setup. Whether this reduction is sufficient to treat tricuspid regurgitation successfully in clinical practice remains to be established. Transcatheter approaches need to be evaluated further, probably with regard to concomitant annuloplasty for higher reduction of tricuspid regurgitation. Copyright © 2017 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  2. The disappearing clip: an unusual complication in MRI biopsy

    PubMed Central

    Bourke, Anita Geraldine; Peter, Prasant; Jose, Chaitra Lesli

    2014-01-01

    MRI-guided biopsies are being increasingly used for otherwise occult breast lesions. Clip migration has been reported however, to the best of our knowledge, there have been no documented cases of entire disappearance of a marker clip. Absence of the postbiopsy marker clip was noted when our patient returned for preoperative hook-wire localisation even though accurate clip placement had been confirmed on the post-MRI biopsy mammogram. PMID:25139917

  3. Using film clips to enhance nursing education.

    PubMed

    Herrman, Judith W

    2006-01-01

    Film clips in nursing education provide a unique way to promote active learning. Several methods for using film clips and combining them with other teaching strategies are discussed. Suggestions for the use of popular clips, logistical aspects of showing clips in class, and legal issues associated with copyright are addressed. Faculty are encouraged to use this strategy to evoke emotional responses, generate discussion, enhance clinical decision making, and provide vicarious learning.

  4. Intravesical markers for delineation of target volume during external focal irradiation of bladder carcinomas.

    PubMed

    Hulshof, Maarten C C M; van Andel, George; Bel, Arjen; Gangel, Pieter; van de Kamer, Jeroen B

    2007-07-01

    A clip forceps was developed which can insert markers at the border of a bladder tumour through a rigid cystoscope. This technique proved to be simple and safe and is of help for delineation of the target volume during CT simulation for focal boost irradiation of bladder cancer.

  5. Mecury in Fin Clips and Scales as Assessment Methods for Predicting Muscle Tissue Mercury Concentrations in Red Drum and Snook

    EPA Science Inventory

    Non-lethal techniques for assessing total mercury concentrations in fish are desired because they minimize impacts on fish populations and allow trends in Hg accumulation to be assessed through repeated sampling of individual fish. This study developed relationships of Hg concent...

  6. The Buffer Diagnostic Prototype: A fault isolation application using CLIPS

    NASA Technical Reports Server (NTRS)

    Porter, Ken

    1994-01-01

    This paper describes problem domain characteristics and development experiences from using CLIPS 6.0 in a proof-of-concept troubleshooting application called the Buffer Diagnostic Prototype. The problem domain is a large digital communications subsystems called the real-time network (RTN), which was designed to upgrade the launch processing system used for shuttle support at KSC. The RTN enables up to 255 computers to share 50,000 data points with millisecond response times. The RTN's extensive built-in test capability but lack of any automatic fault isolation capability presents a unique opportunity for a diagnostic expert system application. The Buffer Diagnostic Prototype addresses RTN diagnosis with a multiple strategy approach. A novel technique called 'faulty causality' employs inexact qualitative models to process test results. Experimental knowledge provides a capability to recognize symptom-fault associations. The implementation utilizes rule-based and procedural programming techniques, including a goal-directed control structure and simple text-based generic user interface that may be reusable for other rapid prototyping applications. Although limited in scope, this project demonstrates a diagnostic approach that may be adapted to troubleshoot a broad range of equipment.

  7. A comparison of two endoscopic closures: over-the-scope clip (OTSC) versus KING closure (endoloop + clips) in a randomized long-term experimental study.

    PubMed

    Dolezel, R; Ryska, O; Kollar, M; Juhasova, J; Kalvach, J; Ryska, M; Martinek, J

    2016-11-01

    Both over-the-scope clip (OTSC) and KING (endoloop + clips) closures provide reliable and safe full-thickness endoscopic closure. Nevertheless, OTSC clip demonstrated significantly inferior histological healing in the short-term follow-up. To compare OTSC versus KING closure of a perforation with regard to long-term effectiveness and macroscopic and histological quality of healing. We performed a randomized experimental study with 16 mini-pigs (mean weight 43.2 ± 11.2 kg). A standardized perforation was performed on the anterior sigmoid wall. KING closure (n = 8) was attained by approximation of an endoloop fixed to the margins of a perforation with endoclips. OTSC closure (n = 8) was performed by deploying OTSC (OVESCO) over the defect. Pigs underwent a control sigmoidoscopy 8 months after the closure to assess the macroscopic quality of healing. Then, autopsy was performed and the rectosigmoid was sent for histopathological assessment. All closures were completed successfully without air leaks. The duration of closure was similar in both techniques (OTSC 17.8 ± 7.6 min vs. KING 19.6 ± 8.8 min). At autopsy, all KING closures (100 %) were healed with a flat scar without signs of leakage. Microscopically, no inflammatory changes were observed after KING closure. In the OTSC group, microscopic ulcers were present in two pigs (25 %), cryptal abscesses in three pigs (38 %) and significant neutrophil accumulation in all eight pigs (P < 0.01). Giant cell granulomas, dysplasia or abundant scarification was not observed in either group. Both OTSC and KING closures offer a long-term reliable seal of a gastrointestinal perforation without stenosis or fistulas. KING closure provides long-term histologically superior healing.

  8. Sex Differences in Emotional Evaluation of Film Clips: Interaction with Five High Arousal Emotional Categories.

    PubMed

    Maffei, Antonio; Vencato, Valentina; Angrilli, Alessandro

    2015-01-01

    The present study aimed to investigate gender differences in the emotional evaluation of 18 film clips divided into six categories: Erotic, Scenery, Neutral, Sadness, Compassion, and Fear. 41 female and 40 male students rated all clips for valence-pleasantness, arousal, level of elicited distress, anxiety, jittery feelings, excitation, and embarrassment. Analysis of positive films revealed higher levels of arousal, pleasantness, and excitation to the Scenery clips in both genders, but lower pleasantness and greater embarrassment in women compared to men to Erotic clips. Concerning unpleasant stimuli, unlike men, women reported more unpleasantness to the Compassion, Sadness, and Fear compared to the Neutral clips and rated them also as more arousing than did men. They further differentiated the films by perceiving greater arousal to Fear than to Compassion clips. Women rated the Sadness and Fear clips with greater Distress and Jittery feelings than men did. Correlation analysis between arousal and the other emotional scales revealed that, although men looked less aroused than women to all unpleasant clips, they also showed a larger variance in their emotional responses as indicated by the high number of correlations and their relatively greater extent, an outcome pointing to a masked larger sensitivity of part of male sample to emotional clips. We propose a new perspective in which gender difference in emotional responses can be better evidenced by means of film clips selected and clustered in more homogeneous categories, controlled for arousal levels, as well as evaluated through a number of emotion focused adjectives.

  9. Perioperative hair removal: A review of best practice and a practice improvement opportunity.

    PubMed

    Spencer, Maureen; Barnden, Marsha; Johnson, Helen Boehm; Fauerbach, Loretta Litz; Graham, Denise; Edmiston, Charles E

    2018-06-01

    The current practice of perioperative hair removal reflects research-driven changes designed to minimize the risk of surgical wound infection. An aspect of the practice which has received less scrutiny is the clean-up of the clipped hair. This process is critical. The loose fibers represent a potential infection risk because of the micro-organisms they can carry, but their clean-up can pose a logistical problem because of the time required to remove them. Research has demonstrated that the most commonly employed means of clean-up, the use of adhesive tape or sticky mitts, can be both ineffective and time-consuming in addition to posing an infection risk from cross-contamination. Recently published research evaluating surgical clippers fitted with a vacuum-assisted hair collection device highlights the potential for significant practice improvement in the perioperative hair removal clean-up process. These improvements include not only further mitigation of potential infection risk but also substantial OR time and cost savings.

  10. Evaluation and Impact of Workflow Interruptions During Robot-assisted Surgery.

    PubMed

    Allers, Jenna C; Hussein, Ahmed A; Ahmad, Nabeeha; Cavuoto, Lora; Wing, Joseph F; Hayes, Robin M; Hinata, Nobuyuki; Bisantz, Ann M; Guru, Khurshid A

    2016-06-01

    To analyze and categorize causes for interruptions during robot-assisted surgery. We analyzed 10 robot-assisted prostatectomies that were performed by 3 surgeons from October 2014 to June 2015. Interruptions to surgery were defined in terms of duration, stage of surgery, personnel involved, reasons, and impact of the interruption on the surgical workflow. The main reasons for interruptions included the following: console surgeons switching (29%); preparation of the surgical equipment, such as cleaning or changing the camera (29%) or an instrument (27%); or when a suture, stapler, or clip was needed (12%). The most common interruption duration was 10-29 seconds (47.6%), and the least common interruption duration was greater than 90 seconds (3.6%). Additionally, about 14% of the interruptions were considered avoidable, whereas the remaining 86% of interruptions were necessary for surgery. By identifying and analyzing interruptions, we can develop evidence-based strategies to improve operating room efficiency, lower costs, and advance patient safety. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. Multiple intracranial aneurysms and moyamoya disease associated with microcephalic osteodysplastic primordial dwarfism type II: surgical considerations.

    PubMed

    Waldron, James S; Hetts, Steven W; Armstrong-Wells, Jennifer; Dowd, Christopher F; Fullerton, Heather J; Gupta, Nalin; Lawton, Michael T

    2009-11-01

    Microcephalic osteodysplastic primordial dwarfism type II (MOPD II) is a rare genetic syndrome characterized by extremely small stature and microcephaly, and is associated in 25% of patients with intracranial aneurysms and moyamoya disease. Although aneurysmal subarachnoid hemorrhage and stroke are leading causes of morbidity and death in these patients, MOPD II is rarely examined in the neurosurgical literature. The authors report their experience with 3 patients who presented with MOPD II, which includes a patient with 8 aneurysms (the most aneurysms reported in the literature), and the first report of a patient with both moyamoya disease and multiple aneurysms. The poor natural history of these lesions indicates aggressive microsurgical and/or endovascular therapy. Microsurgery, whether for aneurysm clip placement or extracranial-intracranial bypass, is challenging due to tight surgical corridors and diminutive arteries in these patients, but is technically feasible and strongly indicated when multiple aneurysms must be treated or cerebral revascularization is needed.

  12. Does Warm-Up Training in a Virtual Reality Simulator Improve Surgical Performance? A Prospective Randomized Analysis.

    PubMed

    da Cruz, José Arnaldo Shiomi; Dos Reis, Sabrina Thalita; Cunha Frati, Rodrigo Marcus; Duarte, Ricardo Jordão; Nguyen, Hiep; Srougi, Miguel; Passerotti, Carlo Camargo

    Virtual reality surgical simulators (VRSS) have been showing themselves as a valuable tool in laparoscopy training and education. Taking in consideration the effectiveness of the VRSS, new uses for this tool have been purposed. In sports, warming up before exercise clearly shows benefit in performance. It is hypothesized that warming up in the VRSS before going to the operating room may show benefit in surgical performance. Verify whether there is benefit in surgical performance with preoperatory warm-up using a VRSS. A total of 20 medical students with basic knowledge in laparoscopy were divided in 2 groups (I and II). Group I performed a laparoscopic cholecystectomy in a porcine model. Group II performed preoperative warm-up in a VRSS and then performed a laparoscopic cholecystectomy in a porcine model. The performance between both groups was compared regarding quantitative parameters (time for dissection of the gallbladder pedicle, time for clipping the pedicle, time for cutting the pedicle, time for gallbladder removal, total operative time, and aspirated blood loss) and qualitative parameters (depth perception, bimanual dexterity, efficiency, tissue handling, and autonomy) based on a previously validated score system, in which the higher the score, the better the result. Data were analyzed with level of significance of 5%. The group that underwent preoperative warm-up (group II) showed significantly superior results as to the time for dissection of the gallbladder pedicle (11.91 ± 9.85 vs. 4.52 ± 2.89min, p = 0.012), time for clipping the pedicle (5.51 ± 2.36 vs. 2.89 ± 2.76min, p = 0.004), time for cutting the pedicle (1.84 ± 0.7 vs. 1.13 ± 0.51, p = 0.019), aspirated blood loss (171 ± 112 vs. 57 ± 27.8ml, p = 0.006), depth perception (4.5 ± 0.7 vs. 3.3 ± 0.67, p = 0.004), bianual dexterity (4.2 ± 0.78 vs. 3.3 ± 0.67, p = 0.004), tissue handling (4.2 ± 0.91 vs. 3.6 ± 0.66, p = 0.012), and autonomy (4.9 ± 0.31 vs. 3.6 ± 0.96, p = 0.028). There was no difference in time for gallbladder removal (11.58 ± 4.31 vs. 15.08 ± 4.51min, p = 0.096), total operative time (30.8 ± 11.07 vs. 25.60 ± 5.10min, p = 0.188), and efficiency (4 ± 0.66 vs. 3.6 ± 0.69, p = 0.320). The practice of preoperative warm-up training seems to benefit surgical performance even in subject with mild laparoscopic experience. Copyright © 2016 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  13. Surgical Management of Aneurysmal Hematomas: Prognostic Factors and Outcome.

    PubMed

    Meneghelli, P; Cozzi, F; Hasanbelliu, A; Locatelli, F; Pasqualin, Alberto

    2016-01-01

    From 1991 until 2013, 304 patients with intracranial hematomas from aneurysmal rupture were managed surgically in our department, constituting 17 % of all patients with aneurysmal rupture. Of them, 242 patents presented with isolated intracerebral hematomas (in 69 cases associated with significant intraventricular hemorrhage), 50 patients presented with combined intracerebral and subdural hematomas (in 11 cases associated with significant intraventricular hemorrhage), and 12 presented with an isolated subdural hematoma. The surgical procedure consisted of simultaneous clipping of the aneurysm and evacuation of the hematoma in all cases. After surgery, 16 patients (5 %) submitted to an additional decompressive hemicraniectomy, and 66 patients (21 %) submitted to a ventriculo-peritoneal shunt. Clinical outcomes were assessed at discharge and at 6 months, using the modified Rankin Scale (mRS); a favorable outcome (mRS 0-2) was observed in 10 % of the cases at discharge, increasing to 31 % at 6 months; 6-month mortality was 40 %. Applying uni- and multivariate analysis, the following risk factors were associated with a significantly worse outcome: age >60; preoperative Hunt-Hess grades IV-V; pupillary mydriasis (only on univariate); midline shift >10 mm; hematoma volume >30 cc; and the presence of hemocephalus (i.e., packed intraventricular hemorrhage). Based on these results, an aggressive surgical treatment should be adopted for most cases with aneurysmal hematomas, excluding patients with bilateral mydriasis persisting after rescue therapy.

  14. Automated revision of CLIPS rule-bases

    NASA Technical Reports Server (NTRS)

    Murphy, Patrick M.; Pazzani, Michael J.

    1994-01-01

    This paper describes CLIPS-R, a theory revision system for the revision of CLIPS rule-bases. CLIPS-R may be used for a variety of knowledge-base revision tasks, such as refining a prototype system, adapting an existing system to slightly different operating conditions, or improving an operational system that makes occasional errors. We present a description of how CLIPS-R revises rule-bases, and an evaluation of the system on three rule-bases.

  15. CLIPS: A proposal for improved usability

    NASA Technical Reports Server (NTRS)

    Patton, Charles R.

    1990-01-01

    This paper proposes the enhancement of the CLIPS user interface to improve the over-all usability of the CLIPS development environment. It suggests some directions for the long term growth of the user interface, and discusses some specific strengths and weaknesses of the current CLIPS PC user interface. Every user of CLIPS shares a common experience: his/her first interaction with the system itself. As with any new language, between the process of installing CLIPS on the appropriate computer and the completion of a large application, an intensive learning process takes place. For those with extensive programming knowledge and LISP backgrounds, this experience may have been mostly interesting and pleasant. Being familiar with products that are similar to CLIPS in many ways, these users enjoy a relatively short training period with the product. Already familiar with many of the functions they wish to employ, experienced users are free to focus on the capabilities of CLIPS that make it uniquely useful within their working environment.

  16. [Modified Misgav-Labach at a tertiary hospital].

    PubMed

    Martínez Ceccopieri, David Alejandro; Barrios Prieto, Ernesto; Martínez Ríos, David

    2012-08-01

    According to several studies from around the globe, the modified Misgav Ladach technique simplifies the surgical procedure for cesarean section, reduces operation time, costs, and complications, and optimizes obstetric and perinatal outcomes. Compare obstetric outcomes between patients operated on using traditional cesarean section technique and those operated on using modified Misgav Ladach technique. The study included 49 patients operated on using traditional cesarean section technique and 47 patients operated on using modified Misgav Ladach technique to compare the outcomes in both surgical techniques. The modified Misgav Ladach technique was associated with more benefits than those of the traditional technique: less surgical bleeding, less operation time, less analgesic total doses, less rescue analgesic doses and less need of more than one analgesic drug. The modified Misgav Ladach surgical technique was associated with better obstetric results than those of the traditional surgical technique; this concurs with the results reported by other national and international studies.

  17. Surgical treatment of functional ischemic mitral regurgitation.

    PubMed

    Jensen, Henrik

    2015-03-01

    In many ways we are at a crossroad in terms of what constitutes optimal FIMR treatment: is CABG combined with mitral valve ring annuloplasty better than CABG alone in moderate FIMR? Is mitral valve repair really better than replacement? And does adding a valvular repair or subvalvular reverse remodeling procedure shift that balance? In the present thesis I aim to shed further light on these questions by addressing the current status and future perspectives of the surgical treatment of FIMR. CURRENT SURGICAL TREATMENT FOR FIMR. CABG alone: The overall impression from the literature is that patients are left with a high grade of persistent/recurrent FIMR from isolated CABG. CABG is most effective to treat FIMR in patients with viable myocardium (at least five viable segments) and absence of dyssynchrony between papillary muscles (< 60 ms). Mitral valve ring annuloplasty. A vast number of different designs are available to perform mitral valve ring annuloplasty with variations over the theme of complete/partial and rigid/semi-rigid/flexible. Also, the three-dimensional shape of the rigid and semi-rigid rings is the subject of great variation. A rigid or semi-rigid down-sized mitral valve ring annuloplasty is the most advocated treatment in chronic FIMR grade 2+ or higher. Combined CABG and mitral valve ring annuloplasty: CABG combined with mitral valve ring annuloplasty leads to reverse LV remodeling and reduced volumes. Despite this, the recurrence rate after combined CABG and mitral valve ring annuloplasty is 20-30% at 2-4 years follow-up. This is also true for studies strictly using down-sized mitral valve ring annuloplasty by two sizes. A number of preoperative risk factors to develop recurrent FIMR were identified, e.g. LVEDD > 65-70 mm, coaptation depth > 10 mm, anterior leaflet angle > 27-39.5°, posterior leaflet angle > 45° and interpapillary muscle distance > 20 mm. CABG alone vs. combined CABG and mitral valve ring annuloplasty: The current available literature, including three randomized studies and a meta analysis, indicate that combined CABG and mitral valve ring annuloplasty has no late survival difference compared with CABG alone, and early mortality might even be higher. Meanwhile, adding a mitral valve ring annuloplasty results in a lower NYHA functional class, most likely as a consequence of a lower incidence of persistent or recurrent FIMR. More randomized studies are being conducted to further address this topic. Mitral valve ring annuloplasty vs. mitral valve replacement. The early survival may be higher after repair compared with replacement, meanwhile, the literature is more ambiguous in terms of late survival advantages, and recent reports find no late survival advantage from repair over replacement. The recurrence rates after ring annuloplasty addressed above were also present in this subset of patients, whereas the incidence of recurrent FIMR after valve replacement is scarcely reported. There was an overall tendency of slightly higher incidence of reoperations after ring annuloplasty. The mitral valve annulus: Innovations in mitral valve ring annuloplasty: The latest innovation in mitral valve ring annuloplasty design includes adjustable rings, allowing adjustment of septo-lateral dimensions intra- or postoperatively. Minimally invasive ring annuloplasty using indirect coronary sinus devices, has been introduced, but so far have produced suboptimal results in terms of safety and efficacy. Also, first in man testing of direct percutaneous catheter based mitral annuloplasty techniques have been conducted. Leaflets and chordae: Direct repair techniques: Surgical methods have been developed to directly address the mitral valve leaflets and chordae tendineae to correct leaflet tethering in FIMR. Both the Alfieri stich and the minimally invasive MitraClip attaches the anterior and posterior leaflets, typically the A2-P2 region, to correct incomplete leaflet coaptation. Patch augmentation of the posterior leaflet in the P2-P3 region increases coaptation in the area most prone to cause FIMR. Chordal cutting of the secondary "strut" chordae releases the anterior leaflet from the tethering due to papillary muscle displacement and improves mitral valve geometry. The mitral subvalvular apparatus: Numerous subvalvular approaches to improve outcome in patients with FIMR have been introduced. They include very invasive techniques such as surgical ventricular restoration procedure, surgical techniques directly addressing the papillary muscle dis-placement, and beating heart procedures using transventricular and epicardial devices applied in a few minutes. The role of the transventricular and epicardial devices still remains to be defined and many of these devices seem to have a hard time ganing their footing in the clinical practise and until now only constitute a footnote in the surgical literature. Meanwhile, the current results with adjunct techniques to CABG and ring annuloplasty, such as the papillary muscle approximation technique introduced by Hvass et al and the papillary muscle relocation technique introduced by Kron et al and further developed by Langer et al are gaining continuing support in the surgical community since these techniques can be used with only little added time consumption but with very good clinical outcome.

  18. Seismic signals hard clipping overcoming

    NASA Astrophysics Data System (ADS)

    Olszowa, Paula; Sokolowski, Jakub

    2018-01-01

    In signal processing the clipping is understand as the phenomenon of limiting the signal beyond certain threshold. It is often related to overloading of a sensor. Two particular types of clipping are being recognized: soft and hard. Beyond the limiting value soft clipping reduces the signal real gain while the hard clipping stiffly sets the signal values at the limit. In both cases certain amount of signal information is lost. Obviously if one possess the model which describes the considered signal and the threshold value (which might be slightly more difficult to obtain in the soft clipping case), the attempt of restoring the signal can be made. Commonly it is assumed that the seismic signals take form of an impulse response of some specific system. This may lead to belief that the sine wave may be the most appropriate to fit in the clipping period. However, this should be tested. In this paper the possibility of overcoming the hard clipping in seismic signals originating from a geoseismic station belonging to an underground mine is considered. A set of raw signals will be hard-clipped manually and then couple different functions will be fitted and compared in terms of least squares. The results will be then analysed.

  19. CLIPS: The C language integrated production system

    NASA Technical Reports Server (NTRS)

    Riley, Gary

    1994-01-01

    Expert systems are computer programs which emulate human expertise in well defined problem domains. The potential payoff from expert systems is high: valuable expertise can be captured and preserved, repetitive and/or mundane tasks requiring human expertise can be automated, and uniformity can be applied in decision making processes. The C Language Integrated Production System (CLIPS) is an expert system building tool, developed at the Johnson Space Center, which provides a complete environment for the development and delivery of rule and/or object based expert systems. CLIPS was specifically designed to provide a low cost option for developing and deploying expert system applications across a wide range of hardware platforms. The commercial potential of CLIPS is vast. Currently, CLIPS is being used by over 5,000 individuals throughout the public and private sector. Because the CLIPS source code is readily available, numerous groups have used CLIPS as the basis for their own expert system tools. To date, three commercially available tools have been derived from CLIPS. In general, the development of CLIPS has helped to improve the ability to deliver expert system technology throughout the public and private sectors for a wide range of applications and diverse computing environments.

  20. 76 FR 26242 - Paper Clips From the People's Republic of China: Final Results of Expedited Sunset Review of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-06

    ... order are plastic and vinyl covered paper clips, butterfly clips, binder clips, or other paper fasteners... order is revoked. Parties can obtain a public copy of the I&D Memo from the Central Records Unit, room...

  1. Annual Removal of Aboveground Plant Biomass Alters Soil Microbial Responses to Warming

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xue, Kai; Yuan, Mengting M.; Xie, Jianping

    Clipping (i.e., harvesting aboveground plant biomass) is common in agriculture and for bioenergy production. However, microbial responses to clipping in the context of climate warming are poorly understood. We investigated the interactive effects of grassland warming and clipping on soil properties and plant and microbial communities, in particular, on microbial functional genes. Clipping alone did not change the plant biomass production, but warming and clipping combined increased the C4 peak biomass by 47% and belowground net primary production by 110%. Clipping alone and in combination with warming decreased the soil carbon input from litter by 81% and 75%, respectively. Withmore » less carbon input, the abundances of genes involved in degrading relatively recalcitrant carbon increased by 38% to 137% in response to either clipping or the combined treatment, which could weaken long-term soil carbon stability and trigger positive feedback with respect to warming. Clipping alone also increased the abundance of genes for nitrogen fixation, mineralization, and denitrification by 32% to 39%. Such potentially stimulated nitrogen fixation could help compensate for the 20% decline in soil ammonium levels caused by clipping alone and could contribute to unchanged plant biomass levels. Moreover, clipping tended to interact antagonistically with warming, especially with respect to effects on nitrogen cycling genes, demonstrating that single-factor studies cannot predict multifactorial changes. These results revealed that clipping alone or in combination with warming altered soil and plant properties as well as the abundance and structure of soil microbial functional genes. Aboveground biomass removal for biofuel production needs to be reconsidered, as the long-term soil carbon stability may be weakened. IMPORTANCE Global change involves simultaneous alterations, including those caused by climate warming and land management practices (e.g., clipping). Data on the interactive effects of warming and clipping on ecosystems remain elusive, particularly in microbial ecology. This study found that clipping alters microbial responses to warming and demonstrated the effects of antagonistic interactions between clipping and warming on microbial functional genes. Clipping alone or combined with warming enriched genes degrading relatively recalcitrant carbon, likely reflecting the decreased quantity of soil carbon input from litter, which could weaken long-term soil C stability and trigger positive warming feedback. These results have important implications in assessing and predicting the consequences of global climate change and indicate that the removal of aboveground biomass for biofuel production may need to be reconsidered.« less

  2. Annual Removal of Aboveground Plant Biomass Alters Soil Microbial Responses to Warming

    DOE PAGES

    Xue, Kai; Yuan, Mengting M.; Xie, Jianping; ...

    2016-09-27

    Clipping (i.e., harvesting aboveground plant biomass) is common in agriculture and for bioenergy production. However, microbial responses to clipping in the context of climate warming are poorly understood. We investigated the interactive effects of grassland warming and clipping on soil properties and plant and microbial communities, in particular, on microbial functional genes. Clipping alone did not change the plant biomass production, but warming and clipping combined increased the C4 peak biomass by 47% and belowground net primary production by 110%. Clipping alone and in combination with warming decreased the soil carbon input from litter by 81% and 75%, respectively. Withmore » less carbon input, the abundances of genes involved in degrading relatively recalcitrant carbon increased by 38% to 137% in response to either clipping or the combined treatment, which could weaken long-term soil carbon stability and trigger positive feedback with respect to warming. Clipping alone also increased the abundance of genes for nitrogen fixation, mineralization, and denitrification by 32% to 39%. Such potentially stimulated nitrogen fixation could help compensate for the 20% decline in soil ammonium levels caused by clipping alone and could contribute to unchanged plant biomass levels. Moreover, clipping tended to interact antagonistically with warming, especially with respect to effects on nitrogen cycling genes, demonstrating that single-factor studies cannot predict multifactorial changes. These results revealed that clipping alone or in combination with warming altered soil and plant properties as well as the abundance and structure of soil microbial functional genes. Aboveground biomass removal for biofuel production needs to be reconsidered, as the long-term soil carbon stability may be weakened. IMPORTANCE Global change involves simultaneous alterations, including those caused by climate warming and land management practices (e.g., clipping). Data on the interactive effects of warming and clipping on ecosystems remain elusive, particularly in microbial ecology. This study found that clipping alters microbial responses to warming and demonstrated the effects of antagonistic interactions between clipping and warming on microbial functional genes. Clipping alone or combined with warming enriched genes degrading relatively recalcitrant carbon, likely reflecting the decreased quantity of soil carbon input from litter, which could weaken long-term soil C stability and trigger positive warming feedback. These results have important implications in assessing and predicting the consequences of global climate change and indicate that the removal of aboveground biomass for biofuel production may need to be reconsidered.« less

  3. Surgical management of gynecomastia: experience of a general surgery center.

    PubMed

    Longheu, A; Medas, F; Corrias, F; Farris, S; Tatti, A; Pisano, G; Erdas, E; Calò, P G

    2016-01-01

    Gynecomastia is a common finding in male population of all ages. The aim of our study was to present our experience and goals in surgical treatment of gynecomastia. Clinical records of patients affected by gynecomastia referred to our Department of Surgery between September 2008 and January 2015 were analyzed. 50 patients were included in this study. Gynecomastia was monolateral in 12 patients (24%) and bilateral in 38 (76%); idiopathic in 41 patients (82%) and secondary in 9 (18%). 39 patients (78%) underwent surgical operation under general anaesthesia, 11 (22%) under local anaesthesia. 3 patients (6%) presented recurrent disease. Webster technique was performed in 28 patients (56%), Davidson technique in 16 patients (32%); in 2 patients (4%) Pitanguy technique was performed and in 4 patients (8%) a mixed surgical technique was performed. Mean surgical time was 80.72±35.14 minutes, median postoperative stay was 1.46±0.88 days. 2 patients (4%) operated using Davidson technique developed a hematoma, 1 patient (2%) operated with the same technique developed hypertrophic scar. Several surgical techniques are described for surgical correction of gynecomastia. If performed by skilled general surgeons surgical treatment of gynecomastia is safe and permits to reach satisfactory aesthetic results.

  4. Neural correlates of emotional regulation while viewing films.

    PubMed

    Shimamura, Arthur P; Marian, Diane E; Haskins, Andrew L

    2013-03-01

    Negative and arousal-inducing film clips were used to assess the neural correlates of emotional expression and suppression. Compared to viewing neutral clips, both negative (disgusting) and arousal (action) clips activated primarily posterior regions in the parietal and occipital cortex when participants were instructed to express their emotions. When instructed to suppress their emotions while viewing negative clips, a broad frontoparietal network was activated that included lateral, medial, and orbital regions in the prefrontal cortex as well as lateral and medial regions of the posterior parietal cortex. The suppression of arousal clips also activated prefrontal and parietal regions, though not to the same extent as the suppression of negative clips. The findings demonstrate the potency of using movies to engage emotional processes and highlight a broad frontoparietal network that is engaged during the suppression of negative film clips.

  5. IDENTIFICATION BADGE WITH DETACHABLE CLIP

    DOEpatents

    Burns, M.T.

    1962-09-18

    The clip has a long slot with a round enlarged end, flat on one side. The badge has a headed member that is circular except for a flat side. The badge is connected to, or disconnected from, the clip by insertion of the headed member through the enlarged end of the slot in the clip. The badge is unlikely to be accidentally disconnected from the clip while being worn on a worker's clothing, because the weight of the badge keeps the headed member away from the enlarged end of the slot in the clip, and the headed member can pass through the enlarged end of the slot only at one relative angular position between badge and clip, namely, that angle at which the flat side of the headed member is coincident with the flat side of the enlarged end of the slot. (AEC)

  6. Sex Differences in Emotional Evaluation of Film Clips: Interaction with Five High Arousal Emotional Categories

    PubMed Central

    Maffei, Antonio; Vencato, Valentina; Angrilli, Alessandro

    2015-01-01

    The present study aimed to investigate gender differences in the emotional evaluation of 18 film clips divided into six categories: Erotic, Scenery, Neutral, Sadness, Compassion, and Fear. 41 female and 40 male students rated all clips for valence-pleasantness, arousal, level of elicited distress, anxiety, jittery feelings, excitation, and embarrassment. Analysis of positive films revealed higher levels of arousal, pleasantness, and excitation to the Scenery clips in both genders, but lower pleasantness and greater embarrassment in women compared to men to Erotic clips. Concerning unpleasant stimuli, unlike men, women reported more unpleasantness to the Compassion, Sadness, and Fear compared to the Neutral clips and rated them also as more arousing than did men. They further differentiated the films by perceiving greater arousal to Fear than to Compassion clips. Women rated the Sadness and Fear clips with greater Distress and Jittery feelings than men did. Correlation analysis between arousal and the other emotional scales revealed that, although men looked less aroused than women to all unpleasant clips, they also showed a larger variance in their emotional responses as indicated by the high number of correlations and their relatively greater extent, an outcome pointing to a masked larger sensitivity of part of male sample to emotional clips. We propose a new perspective in which gender difference in emotional responses can be better evidenced by means of film clips selected and clustered in more homogeneous categories, controlled for arousal levels, as well as evaluated through a number of emotion focused adjectives. PMID:26717488

  7. 21 CFR 886.1410 - Ophthalmic trial lens clip.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ophthalmic trial lens clip. 886.1410 Section 886...) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1410 Ophthalmic trial lens clip. (a) Identification. An ophthalmic trial lens clip is a device intended to hold prisms, spheres, cylinders, or...

  8. 21 CFR 882.5200 - Aneurysm clip.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Aneurysm clip. 882.5200 Section 882.5200 Food and... NEUROLOGICAL DEVICES Neurological Therapeutic Devices § 882.5200 Aneurysm clip. (a) Identification. An aneurysm clip is a device used to occlude an intracranial aneurysm (a balloonlike sac formed on a blood vessel...

  9. 21 CFR 882.5200 - Aneurysm clip.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Aneurysm clip. 882.5200 Section 882.5200 Food and... NEUROLOGICAL DEVICES Neurological Therapeutic Devices § 882.5200 Aneurysm clip. (a) Identification. An aneurysm clip is a device used to occlude an intracranial aneurysm (a balloonlike sac formed on a blood vessel...

  10. 21 CFR 882.5200 - Aneurysm clip.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Aneurysm clip. 882.5200 Section 882.5200 Food and... NEUROLOGICAL DEVICES Neurological Therapeutic Devices § 882.5200 Aneurysm clip. (a) Identification. An aneurysm clip is a device used to occlude an intracranial aneurysm (a balloonlike sac formed on a blood vessel...

  11. Extravasal occlusion of large vessels with titanic clips: efficiency, indications, and contraindications.

    PubMed

    Vasilenko, Yu V; Kim, A I; Kotov, S A

    2002-11-01

    The mechanism of extravasal occlusion of blood vessels with titanic clips "Atrauclip" and "Ligaclip extra" was studied in order to reveal indications and contraindications to their use. Occlusion with the clips of both types was ineffective in vessels with a diameter of >7.0 mm. Arteritis or the presence of an intravascular occlusion facility in the vessel were also the contraindications for clip occlusion. In overcases the procedure of occlusion with titanic clips was efficient and atraumatic.

  12. Influences of emotion on context memory while viewing film clips.

    PubMed

    Anderson, Lisa; Shimamura, Arthur P

    2005-01-01

    Participants listened to words while viewing film clips (audio off). Film clips were classified as neutral, positively valenced, negatively valenced, and arousing. Memory was assessed in three ways: recall of film content, recall of words, and context recognition. In the context recognition test, participants were presented a word and determined which film clip was showing when the word was originally presented. In two experiments, context memory performance was disrupted when words were presented during negatively valenced film clips, whereas it was enhanced when words were presented during arousing film clips. Free recall of words presented during the negatively valenced films was also disrupted. These findings suggest multiple influences of emotion on memory performance.

  13. Is the use of 55" LCD 3D screen practicable in large seminar to lecture hall size audiences?

    NASA Astrophysics Data System (ADS)

    Ilgner, Justus; Sparrer, Ingo; Westhofen, Martin

    2013-03-01

    Introduction: The presentation of surgical contents to undergraduate medical students can be challenging, as the surgical approach is often different from the anatomist's perspective that is reproduced in textbooks. Although there are many options to record endoscopic, microscopic as well as "open" surgical procedures, presentation of contents still can be costly and entail a loss in picture quality including depth impression. Material and methods: We presented seven stereoscopic clips of 30 seconds to minute and 20 seconds each to 64 medical students (43 female / 21 male) as part of the "sensory organs" course module in 4th year; using one 55" LCD 3D screen with line-alternating, circular polarization. Students were asked for their subjective viewing impression and about their opinion on the usefulness of 3D presentations in medical lectures. Results: 63% of students returned their questionnaires completed. The main results (multiple answers allowed) were: 70% noted that 3D presentations made complex anatomy easier to comprehend from an unknown perspective, 48% would feel better motivated to learn surgical procedures, and 38% would generally prefer a 3D lecture to a 2D lecture, while 23% would not see any advantage of 3D presentations whatsoever. Conclusion: While the screen size compared to audience size was far from ideal, it gave medical students, who had not been exposed to surgical procedures in the operating theatre yet, an impression of general approach to microsurgery and how the choice of surgical approach in relation of vital structures can minimize trauma and unwanted effects to the patient. The availability of larger screens, however, may necessitate changes in production of 3D material from the microscope camera onward.

  14. [Robotic laparoscopic cholecystectomy].

    PubMed

    Langer, D; Pudil, J; Ryska, M

    2006-09-01

    Laparoscopic approach profusely utilized in many surgical fields was enhanced by da Vinci robotic surgical system in range of surgery wards, imprimis in the United States today. There was multispecialized robotic centre program initiated in the Central Military Hospital in Prague in December 2005. Within the scope of implementing the da Vinci robotic system to clinical practice we executed robotic-assisted laparoscopic cholecystectomy. We have accomplished elective laparoscopic cholecystectomy using the da Vinci robotic surgical system. Operating working group (two doctors, two scrub nurses) had completed certificated foreign training. Both of the surgeons have many years experience of laparoscopic cholecystectomy. Operator controlled instruments from the surgeon's console, assistant placed clips on ends of cystic duct and cystic artery from auxiliary port after capnoperitoneum installation. We evacuated gallbladder in plastic bag from abdominal cavity in place of original paraumbilical port. We were exploiting three working arms in all our cases, holding surgical camera, electrocautery hook and Cadiere forceps. We had been observing procedure time, technical complications connected with robotic system, length of hospital stay and complication incidence rate. We managed to finish all operations in laparoscopic way. Group of our patients formed 11 male patients (35.5%) and 20 women (64.5%), mean aged 52.5 years in range of 27 77 years. The average operation procedure lasted 100 minutes, in the group of last 11 patients only 69 minutes. We recorded paraumbilical wound infections in 3 (9.7 %) patients. We had not experienced any technical problems with robotic surgical system. Length of hospital stay was 3 days. Considering our initial experience with robotic lasparoscopic cholecystectomy we evaluate da Vinci robotic surgical system to be safe and sophisticated operating manipulator which however does not substitute the surgeon key-role of controlling position and decision competences. Presented results of our group are comparable to conclusions of abroad published works.

  15. Coma and Stroke Following Surgical Treatment of Unruptured Intracranial Aneurysm: An American College of Surgeons National Surgical Quality Improvement Program Study.

    PubMed

    McCutcheon, Brandon A; Kerezoudis, Panagiotis; Porter, Amanda L; Rinaldo, Lorenzo; Murphy, Meghan; Maloney, Patrick; Shepherd, Daniel; Hirshman, Brian R; Carter, Bob S; Lanzino, Giuseppe; Bydon, Mohamad; Meyer, Fredric

    2016-07-01

    A large national surgical registry was used to establish national benchmarks and associated predictors of major neurologic complications (i.e., coma and stroke) after surgical clipping of unruptured intracranial aneurysms. The American College of Surgeons National Surgical Quality Improvement Program data set between 2007 and 2013 was used for this retrospective cohort analysis. Demographic, comorbidity, and operative characteristics associated with the development of a major neurologic complication (i.e., coma or stroke) were elucidated using a backward selection stepwise logistic regression analysis. This model was subsequently used to fit a predictive score for major neurologic complications. Inclusion criteria were met by 662 patients. Of these patients, 57 (8.61%) developed a major neurologic complication (i.e., coma or stroke) within the 30-day postoperative period. On multivariable analysis, operative time (log odds 0.004 per minute; 95% confidence interval [CI], 0.002-0.007), age (log odds 0.05 per year; 95% CI, 0.02-0.08), history of chronic obstructive pulmonary disease (log odds 1.26; 95% CI, 0.43-2.08), and diabetes (log odds 1.15; 95% CI, 0.38-1.91) were associated with an increased odds of major neurologic complications. When patients were categorized according to quartile of a predictive score generated from the multivariable analysis, rates of major neurologic complications were 1.8%, 4.3%, 6.7%, and 21.2%. Using a large, national multi-institutional cohort, this study established representative national benchmarks and a predictive scoring system for major neurologic complications following operative management of unruptured intracranial aneurysms. The model may assist with risk stratification and tailoring of decision making in surgical candidates. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. Using Progressive Video Prompting to Teach Students with Moderate Intellectual Disability to Shoot a Basketball

    ERIC Educational Resources Information Center

    Lo, Ya-yu; Burk, Bradley; Burk, Bradley; Anderson, Adrienne L.

    2014-01-01

    The current study examined the effects of a modified video prompting procedure, namely progressive video prompting, to increase technique accuracy of shooting a basketball in the school gymnasium of three 11th-grade students with moderate intellectual disability. The intervention involved participants viewing video clips of an adult model who…

  17. Seinfeld and Economics: How to Achieve the Revised Bloom's Taxonomy in an Introductory Economics Class

    ERIC Educational Resources Information Center

    Deal, John; Hegde, S. Aaron

    2013-01-01

    This paper presents an innovative teaching technique, the utilization of a popular sitcom to teach an introductory economics course. Using clips from the television show "Seinfeld," instructors can present the oft-perceived difficult, yet basic, economic concepts in an amenable manner, which also enables the achieving of higher levels of…

  18. Practical Public Relations: Effective PR Techniques for School Library/Media Specialists. Monograph Series No. 5.

    ERIC Educational Resources Information Center

    Behm, Mary W., Ed.

    This handbook of publicity ideas suggests activities and themes to highlight services and resources of school media centers, including approaches to students, faculty, administration, and the community at large. A 14-item annotated bibliography and six mailing list addresses are provided as additional sources for ideas. Clip art illustrations…

  19. Production and evaluation of stereoscopic video presentation in surgical training

    NASA Astrophysics Data System (ADS)

    Ilgner, Justus; Kawai, Takashi; Westhofen, Martin; Shibata, Takashi

    2004-05-01

    Stereoscopic video teaching can facilitate understanding for current minimally-invasive operative techniques. This project was created to set up a digital stereoscopic teaching environment for training of ENT residents and medical students. We recorded three ENT operative procedures (tympanoplasty, paranasal sinus operation and laser chordectomy) at the University Hospital Aachen. The material was edited stereoscopically at the Waseda University and converted into a streaming 3-D video format, which does not depend on PAL or NTSC signal standards. Video clips were evaluated by 5 ENT specialists and 11 residents in single sessions on an LCD monitor (8) and a CRT monitor (8). Emphasis was laid on depth perception, visual fatigue and time to achieve stereoscopic impression. Qualitative results were recorded on a visual analogue scale, ranging from 1 (excellent) to 5 (bad). The overall impression was rated 2,06 to 3,13 in the LCD group and 2,0 to 2,62 in the CRT group. The depth impression was rated 1,63 to 2,88 (LCD) and 1,63 to 2,25 (CRT). Stereoscopic video teaching was regarded as useful in ENT training by all participants. Further points for evaluation will be the quantification of depth information as well as the information gain in teaching junior colleagues.

  20. 21 CFR 884.2685 - Fetal scalp clip electrode and applicator.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... Monitoring Devices § 884.2685 Fetal scalp clip electrode and applicator. (a) Identification. A fetal scalp clip electrode and applicator is a device designed to establish electrical contact between fetal skin... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Fetal scalp clip electrode and applicator. 884...

  1. 21 CFR 884.2685 - Fetal scalp clip electrode and applicator.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... Monitoring Devices § 884.2685 Fetal scalp clip electrode and applicator. (a) Identification. A fetal scalp clip electrode and applicator is a device designed to establish electrical contact between fetal skin... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Fetal scalp clip electrode and applicator. 884...

  2. 21 CFR 884.2685 - Fetal scalp clip electrode and applicator.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... Monitoring Devices § 884.2685 Fetal scalp clip electrode and applicator. (a) Identification. A fetal scalp clip electrode and applicator is a device designed to establish electrical contact between fetal skin... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Fetal scalp clip electrode and applicator. 884...

  3. 21 CFR 884.2685 - Fetal scalp clip electrode and applicator.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... Monitoring Devices § 884.2685 Fetal scalp clip electrode and applicator. (a) Identification. A fetal scalp clip electrode and applicator is a device designed to establish electrical contact between fetal skin... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Fetal scalp clip electrode and applicator. 884...

  4. 21 CFR 884.2685 - Fetal scalp clip electrode and applicator.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... Monitoring Devices § 884.2685 Fetal scalp clip electrode and applicator. (a) Identification. A fetal scalp clip electrode and applicator is a device designed to establish electrical contact between fetal skin... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Fetal scalp clip electrode and applicator. 884...

  5. The Effects of Multimodality through Storytelling Using Various Movie Clips

    ERIC Educational Resources Information Center

    Kim, SoHee

    2016-01-01

    This study examines the salient multimodal approaches for communicative competence and learners' reactions through storytelling tasks with three different modes: a silent movie clip, a movie clip with only sound effects, and a movie clip with sound effects and dialogue. In order to measure different multimodal effects and to define better delivery…

  6. Structural changes in the human vas deferens after tantalum clip occlusion and conventional vasectomy.

    PubMed

    Kothari, L K; Gupta, A S

    1978-02-01

    In 15 human subjects, the vasa deferentia were occluded by applying two tantalum clips on one side and by conventional vasectomy with silk ligatures on the other. After 2 weeks, the occluded segments were recovered for histopathologic examination of serial sections. Obstructing the seminal tract did not, as such, produce any significant change in the vas: the distal and proximal segments appeared to be essentially similar and normal. At the actual site of occlusion, however, tantalum clips produced marked flattening of the tube, complete loss of lining epithelium, distortion of the muscular lamellae, and areas of hemorrhage. The lumen was converted into a narrow slit. Under the ligatures, the damage was largely confined to denudation of the mucosal epithelium. The mucosa of the intersegment left unexcised between two clips showed hyalinization, invasion by macrophages, and degeneration of the epithelium. The changes under the clips suggest that, although clip occlusion may offer several advantages, sterility cannot be reversed merely by removing the clips. The mechanisms of these changes, different in the case of clips and ligatures, are discussed and some possible long-term consequences are considered.

  7. Application of Micromirror in Microsurgical Clipping to the Intracranial Aneurysms.

    PubMed

    Zhao, Chao; Ma, Zhiguo; Zhang, Yuhai; Mou, Shanling; Yang, Yunxue; Yang, Yonglin; Sun, Guoqing; Yao, Weicheng

    2018-05-01

    The aim of the study was to explore the values and disadvantages of micromirror in the intracranial aneurysm clipping surgery. Micromirror was used to assist microsurgical clipping to 36 intracranial aneurysms in 31 patients, of which 3 were carotid-ophthalmic artery aneurysms, 3 were anterior choroidal artery aneurysms, 11 were posterior communicating artery aneurysms, 7 were middle cerebral artery aneurysms, 10 were anterior communicating artery or anterior cerebral artery aneurysms, and the rest were a posterior cerebral artery aneurysm and a posterior inferior cerebellar artery aneurysm. The micromirror was used before and after clipping to observe the anatomic features of necks hidden behind and medial to aneurysms, to visualize surrounding neurovascular structures, and to verify the optimal clipping position. Intraoperative indocyanine green fluorescein angiography, postoperative computerized tomography angiography, and digital subtraction angiography confirmed the success of sufficient clipping. Intraoperative indocyanine green angiography, postoperative computerized tomography angiography , or digital subtraction angiography were performed and showed no case of wrong or insufficient clipping of aneurysm. Micromirror-assisted microsurgical clipping to the intracranial aneurysm is safe, sufficient, convenient, and practical.

  8. Spontaneous spinal cerebrospinal fluid leak as a cause of coma after craniotomy for clipping of an unruptured intracranial aneurysm.

    PubMed

    Schievink, Wouter I; Palestrant, David; Maya, M Marcel; Rappard, George

    2009-03-01

    Spontaneous spinal CSF leaks are best known as a cause of orthostatic headache, but may also be the cause of coma. The authors encountered a unique case of a spontaneous spinal CSF leak causing coma 2 days after craniotomy for clipping of an unruptured aneurysm. This 44-year-old woman with autosomal dominant polycystic kidney disease underwent an uneventful craniotomy for an incidental anterior choroidal artery aneurysm. No intraoperative spinal CSF drainage was used. Two days after surgery the patient became comatose with a left oculomotor nerve palsy. Computed tomography scanning revealed a right extraceberal hematoma and loss of gray-white matter differentiation. The hematoma was evacuated and a diagnosis of hemodialysis disequilibrium syndrome was made. Continuous hemodialysis and hyperosmolar therapy were instituted without any improvement. The CT scans were then reinterpreted as showing sagging of the brain, and the patient was placed in the Trendelenburg position which resulted in prompt improvement in her level of consciousness. A CT myelogram demonstrated an upper thoracic CSF leak that eventually required surgical correction. The patient made a complete neurological recovery. Neurological deterioration after craniotomy may be caused by brain sagging caused by a spontaneous spinal CSF leak, similar to intracranial hypotension due to intraoperative lumbar CSF drainage.

  9. New methods of magnet-based instrumentation for NOTES.

    PubMed

    Magdeburg, Richard; Hauth, Daniel; Kaehler, Georg

    2013-12-01

    Laparoscopic surgery has displaced open surgery as the standard of care for many clinical conditions. NOTES has been described as the next surgical frontier with the objective of incision-free abdominal surgery. The principal challenge of NOTES procedures is the loss of triangulation and instrument rigidity, which is one of the fundamental concepts of laparoscopic surgery. To overcome these problems necessitates the development of new instrumentation. material and methods: We aimed to assess the use of a very simple combination of internal and external magnets that might allow the vigorous multiaxial traction/counter-traction required in NOTES procedures. The magnet retraction system consisted of an external magnetic assembly and either small internal magnets attached by endoscopic clips to the designated tissue (magnet-clip-approach) or an endoscopic grasping forceps in a magnetic deflector roll (magnet-trocar-approach). We compared both methods regarding precision, time and efficacy by performing transgastric partial uterus resections with better results for the magnet-trocar-approach. This proof-of-principle animal study showed that the combination of external and internal magnets generates sufficient coupling forces at clinically relevant abdominal wall thicknesses, making them suitable for use and evaluation in NOTES procedures, and provides the vigorous multiaxial traction/counter-traction required by the lack of additional abdominal trocars.

  10. Virtual interactive presence for real-time, long-distance surgical collaboration during complex microsurgical procedures.

    PubMed

    Shenai, Mahesh B; Tubbs, R Shane; Guthrie, Barton L; Cohen-Gadol, Aaron A

    2014-08-01

    The shortage of surgeons compels the development of novel technologies that geographically extend the capabilities of individual surgeons and enhance surgical skills. The authors have developed "Virtual Interactive Presence" (VIP), a platform that allows remote participants to simultaneously view each other's visual field, creating a shared field of view for real-time surgical telecollaboration. The authors demonstrate the capability of VIP to facilitate long-distance telecollaboration during cadaveric dissection. Virtual Interactive Presence consists of local and remote workstations with integrated video capture devices and video displays. Each workstation mutually connects via commercial teleconferencing devices, allowing worldwide point-to-point communication. Software composites the local and remote video feeds, displaying a hybrid perspective to each participant. For demonstration, local and remote VIP stations were situated in Indianapolis, Indiana, and Birmingham, Alabama, respectively. A suboccipital craniotomy and microsurgical dissection of the pineal region was performed in a cadaveric specimen using VIP. Task and system performance were subjectively evaluated, while additional video analysis was used for objective assessment of delay and resolution. Participants at both stations were able to visually and verbally interact while identifying anatomical structures, guiding surgical maneuvers, and discussing overall surgical strategy. Video analysis of 3 separate video clips yielded a mean compositing delay of 760 ± 606 msec (when compared with the audio signal). Image resolution was adequate to visualize complex intracranial anatomy and provide interactive guidance. Virtual Interactive Presence is a feasible paradigm for real-time, long-distance surgical telecollaboration. Delay, resolution, scaling, and registration are parameters that require further optimization, but are within the realm of current technology. The paradigm potentially enables remotely located experts to mentor less experienced personnel located at the surgical site with applications in surgical training programs, remote proctoring for proficiency, and expert support for rural settings and across different counties.

  11. Urinary corticosterone responses to capture and toe-clipping in the cane toad (Rhinella marina) indicate that toe-clipping is a stressor for amphibians.

    PubMed

    Narayan, Edward J; Molinia, Frank C; Kindermann, Christina; Cockrem, John F; Hero, Jean-Marc

    2011-11-01

    Toe-clipping, the removal of one or more toes, is a common method used to individually mark free-living animals. Whilst this method is widely used in studies of amphibians, the appropriateness of the method, and its potential detrimental effects have been the subject of debate. Here, we provide for the first time, evidence that toe-clipping is a stressor in a wild amphibian. We measured urinary corticosterone responses of male cane toads (Rhinella marina) to capture and handling only, and to toe-clipping under field conditions. Urinary testosterone concentrations and white blood cell proportions were also measured. Urinary corticosterone metabolite concentrations increased 6h after capture and handling only and remained high for 24h; corticosterone returned to baseline levels after 48 h and remained low at 72 h post capture and handling. Corticosterone concentrations in toads subjected to toe-clipping increased at 6h to significantly higher concentrations than after capture and handling only, then decreased more slowly than after capture and handling, and were still elevated (approximately double basal level) 72 h after toe-clipping. Testosterone did not change significantly after capture and handling only, whereas after toe-clipping testosterone decreased at 6h and remained low at 72 h. There were weak short-term effects of toe-clipping compared with capture and handling only on white blood cell proportions. We have clearly shown that toe-clipping is a distinctly stronger stressor than capture and handling alone. This indicates that there is an ethical cost of toe-clipping, and this should be considered when planning studies of amphibians. Copyright © 2011 Elsevier Inc. All rights reserved.

  12. Image quality and artefact generation post-cerebral aneurysm clipping using a 64-row multislice computer tomography angiography (MSCTA) technology: A retrospective study and review of the literature.

    PubMed

    Zachenhofer, Iris; Cejna, Manfred; Schuster, Antonius; Donat, Markus; Roessler, Karl

    2010-06-01

    Computed tomography angiography (CTA) is a time and cost saving investigation for postoperative evaluation of clipped cerebral aneurysm patients. A retrospective study was conducted to analyse image quality and artefact generation due to implanted aneurysm clips using a new technology. MSCTA was performed pre- and postoperatively using a Philips Brilliance 64-detector-row CT scanner. Altogether, 32 clipping sites were analysed in 27 patients (11 female and 16 male, mean ages 52a, from 24 to 72 years). Clip number per aneurysm was 2.3 mean (from 1 to 4), 54 clips were made of titanium alloy and 5 of cobalt alloy. Altogether, image quality was rated 1.8 mean, using a scale from 1 (very good) to 5 (unserviceable) and clip artefacts were rated 2.4 mean, using a 5 point rating scale (1 no artefacts, 5 unserviceable due to artefacts). A significant loss of image quality and rise of artefacts was found when using cobalt alloy clips (1.4 versus 4.2 and 2.1 versus 4.0). In 72% of all investigations, an excellent image quality was found. Excluding the cobalt clip group, 85% of scans showed excellent image quality. Artefacts were absent or minimal (grade 1 or 2) in 69% of all investigations and in 81% in the pure titanium clip group. In 64-row MSCTA of good image quality with low artefacts, it was possible to detect small aneurysm remnants of 2mm size in individual patients. By using titanium alloy clips, in our study up to 85% of postoperative CTA images were of excellent quality with absent or minimal artefacts in 81% and seem adequate to detect small aneurysm remnants. Copyright 2010 Elsevier B.V. All rights reserved.

  13. Annual Removal of Aboveground Plant Biomass Alters Soil Microbial Responses to Warming

    PubMed Central

    Xue, Kai; Yuan, Mengting M.; Xie, Jianping; Li, Dejun; Qin, Yujia; Wu, Liyou; Deng, Ye; He, Zhili; Van Nostrand, Joy D.; Luo, Yiqi; Tiedje, James M.

    2016-01-01

    ABSTRACT Clipping (i.e., harvesting aboveground plant biomass) is common in agriculture and for bioenergy production. However, microbial responses to clipping in the context of climate warming are poorly understood. We investigated the interactive effects of grassland warming and clipping on soil properties and plant and microbial communities, in particular, on microbial functional genes. Clipping alone did not change the plant biomass production, but warming and clipping combined increased the C4 peak biomass by 47% and belowground net primary production by 110%. Clipping alone and in combination with warming decreased the soil carbon input from litter by 81% and 75%, respectively. With less carbon input, the abundances of genes involved in degrading relatively recalcitrant carbon increased by 38% to 137% in response to either clipping or the combined treatment, which could weaken long-term soil carbon stability and trigger positive feedback with respect to warming. Clipping alone also increased the abundance of genes for nitrogen fixation, mineralization, and denitrification by 32% to 39%. Such potentially stimulated nitrogen fixation could help compensate for the 20% decline in soil ammonium levels caused by clipping alone and could contribute to unchanged plant biomass levels. Moreover, clipping tended to interact antagonistically with warming, especially with respect to effects on nitrogen cycling genes, demonstrating that single-factor studies cannot predict multifactorial changes. These results revealed that clipping alone or in combination with warming altered soil and plant properties as well as the abundance and structure of soil microbial functional genes. Aboveground biomass removal for biofuel production needs to be reconsidered, as the long-term soil carbon stability may be weakened. PMID:27677789

  14. The effect of correct cross-chest clip use on injury outcomes in young children during motor vehicle crashes.

    PubMed

    Woodford, Evangeline; Brown, Julie; Bilston, Lynne E

    2018-05-19

    Traffic crashes have high mortality and morbidity for young children. Though many specialized child restraint systems improve injury outcomes, no large-scale studies have investigated the cross-chest clip's role during a crash, despite concerns in some jurisdictions about the potential for neck contact injuries from the clips. This study aimed to investigate the relationship between cross-chest clip use and injury outcomes in children between 0 and 4 years of age. Child passengers between 0 and 4 years of age were selected from the NASS-CDS data sets (2003-2014). Multiple regression analysis was used to model injury outcomes while controlling for age, crash severity, crash direction, and restraint type. The primary outcomes were overall Abbreviated Injury Score (AIS) 2+ injury, and the presence of any neck injury. Across all children aged 0-4 years, correct chest clip use was associated with decreased Abbreviated Injury Scale (AIS) 2+ injury (odds ratio [OR] = 0.44, 95% confidence interval [CI], 0.21-0.91) and was not associated with neck injury. However, outcomes varied by age. In children <12 months old, chest clip use was associated with decreased AIS 2+ injury (OR = 0.09, 95% CI, 0.02-0.44). Neck injury (n = 7, all AIS 1) for this age group only occurred with correct cross-chest clip use. For 1- to 4-year-old children, cross-chest clip use had no association with AIS 2+ injury, and correct use significantly decreased the odds of neck injury (OR = 0.49; 95% CI, 0.27-0.87) compared to an incorrectly used or absent cross-chest clip. No serious injuries were directly caused by the chest clips. Correct cross-chest clip use appeared to reduce injury in crashes, and there was no evidence of serious clip-induced injury in children in 5-point harness restraints.

  15. Prophylactic clipping for the prevention of bleeding following wide-field endoscopic mucosal resection of laterally spreading colorectal lesions: an economic modeling study.

    PubMed

    Bahin, Farzan F; Rasouli, Khalid N; Williams, Stephen J; Lee, Eric Y T; Bourke, Michael J

    2016-08-01

    Clinically significant bleeding (CSPEB) is the most common adverse event following endoscopic mucosal resection (EMR) of large sessile and laterally spreading colorectal lesions (LSLs), and is associated with morbidity and resource utilization. CSPEB occurs more frequently with proximal LSLs. Prophylactic clipping of the post-EMR defect may be beneficial in CSPEB prevention. The aim of this study was to determine the cost-effectiveness of a prophylactic clipping strategy. We hypothesized that prophylactic clipping in the proximal colon was cost-effective. An economic model was applied to outcomes from the Australian Colonic Endoscopic Mucosal Resection (ACE) Study. Clip distances of 3, 5, 8, and 10 mm were analyzed. The cost of treating CSPEB was determined from an independent costing agency. The funds needed to spend (FNS) was the cost incurred in order to prevent one episode of CSPEB. A break-even analysis was performed to determine cost equivalence of the costs of clipping and CSPEB. Outcomes of 1717 LSLs (mean size 35.8 mm; 52.6 % proximal colon) that underwent EMR were analyzed. The overall rate of CSPEB was 6.4 % (proximal 8.9 %; distal 3.7 %). Endoscopic management was required in 45 % of CSPEB episodes. With a clip distance of 3 mm, the expected cost of prophylactic clipping was € 1106 per lesion compared with € 157 per lesion for the expected cost of CSPEB without clipping. At 100 % clipping efficacy, the FNS was € 14 826 (proximal and distal lesions € 9309 and € 29 540, respectively). A clip price of € 10.35 was required for the cost of clipping to offset the cost of CSPEB. A prophylactic clipping strategy is not cost-effective and at present cannot be justified for all lesions or selectively for lesions in the proximal colon. ClinicalTrials.gov (NCT01368289). © Georg Thieme Verlag KG Stuttgart · New York.

  16. Prospective, randomized comparison of 3 different hemoclips for the treatment of acute upper GI hemorrhage in an established experimental setting.

    PubMed

    Kato, Masayuki; Jung, Yunho; Gromski, Mark A; Chuttani, Ram; Matthes, Kai

    2012-01-01

    Recently, endoscopic clip application devices have undergone redesign and improvements to optimize their clinical use and effectiveness. Initially designed for the treatment of bleeding nonvariceal lesions, these devices are also increasingly used for the closure of perforations, fistulas, and anastomotic leaks. Several clinical studies, both randomized and nonrandomized, have used endoscopic hemoclips for hemostasis. However, no comparative studies have yet been reported in the literature comparing the latest endoscopic clip devices for usability and effectiveness for hemostasis of acute upper GI hemorrhage. We aimed to compare the usability and efficacy of 3 different types of endoscopic clip application devices in an established experimental setting by using a porcine ex-vivo simulator of upper GI hemorrhage. Randomized, controlled, ex-vivo study. Academic medical center. Spurting vessels were created within ex-vivo porcine stomachs as published in prior studies. The vessels were attached to a pressure transducer to record the pressure of the circulating blood replacement. Before the initiation of bleeding, each vessel was randomized to 1 of 3 endoscopic clipping devices: 2 different commonly used hemoclips deployed through the working channel and 1 novel clip deployed via an over-the-scope applications device. Two investigators treated 45 bleeding sites (15 bleeding sites for each device at various randomized locations in the stomach: fundus, body, and antrum). Usability was measured via the endpoints of procedure time and quantity of clips required to achieve hemostasis. Efficacy was measured via the endpoint of pressure increase (Δp) from baseline to after treatment. All of the 45 hemostasis treatments were carried out successfully. The mean procedure times were significantly different among the hemoclips, with the clip deployed in an over-the-scope fashion requiring significantly less time to attain hemostasis compared with the other 2 clips. For number of clips needed to attain hemostasis, the clip deployed in an over-the-scope fashion was significantly superior to the others. There were also significant differences among the changes in pressure (Δp ± SD) among the different hemoclips tested. Ex-vivo study. In this prospective, randomized ex-vivo study, we observed significant differences in the usability (time to achieve hemostasis and number of clips required) and the efficacy (change in pressure achieved by the hemoclips) among the 3 clips. The clip applied in the over-the-scope fashion was superior to the other 2 tested clips with regard to time to achieve hemostasis and number of clips required. Copyright © 2012 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  17. Alternative Surgical Methods in Patients with Recurrent Palmar Hyperhidrosis and Compensatory Hyperhidrosis.

    PubMed

    Jung, Hee Suk; Lee, Doo Yun; Park, Joon Suk

    2018-03-01

    Recurrent hyperhidrosis after thoracic sympathectomy is an uncomfortable condition, and compensatory hyperhidrosis (CH) is one of the most troublesome side effects. Here, we describe two patients with recurrent palmar hyperhidrosis (PH) and CH over the whole body simultaneously. They were treated with bilateral T4 sympathetic clipping and reconstruction of the sympathetic nerve from a T5 to T8 sympathetic nerve graft, which was transferred to the resected T3 sympathetic bed site. They reported improvements in sweating and were fully satisfied with the results. Our method can be considered as an alternative approach for patients with recurrent PH and CH. © Copyright: Yonsei University College of Medicine 2018.

  18. Surgical management of gynecomastia: experience of a general surgery center

    PubMed Central

    LONGHEU, A.; MEDAS, F.; CORRIAS, F.; FARRIS, S.; TATTI, A.; PISANO, G.; ERDAS, E.; CALÒ, P.G.

    2016-01-01

    Aim Gynecomastia is a common finding in male population of all ages. The aim of our study was to present our experience and goals in surgical treatment of gynecomastia. Patients and Methods Clinical records of patients affected by gynecomastia referred to our Department of Surgery between September 2008 and January 2015 were analyzed. 50 patients were included in this study. Results Gynecomastia was monolateral in 12 patients (24%) and bilateral in 38 (76%); idiopathic in 41 patients (82%) and secondary in 9 (18%). 39 patients (78%) underwent surgical operation under general anaesthesia, 11 (22%) under local anaesthesia. 3 patients (6%) presented recurrent disease. Webster technique was performed in 28 patients (56%), Davidson technique in 16 patients (32%); in 2 patients (4%) Pitanguy technique was performed and in 4 patients (8%) a mixed surgical technique was performed. Mean surgical time was 80.72±35.14 minutes, median postoperative stay was 1.46±0.88 days. 2 patients (4%) operated using Davidson technique developed a hematoma, 1 patient (2%) operated with the same technique developed hypertrophic scar. Conclusions Several surgical techniques are described for surgical correction of gynecomastia. If performed by skilled general surgeons surgical treatment of gynecomastia is safe and permits to reach satisfactory aesthetic results. PMID:27938530

  19. Framework for performance evaluation of face, text, and vehicle detection and tracking in video: data, metrics, and protocol.

    PubMed

    Kasturi, Rangachar; Goldgof, Dmitry; Soundararajan, Padmanabhan; Manohar, Vasant; Garofolo, John; Bowers, Rachel; Boonstra, Matthew; Korzhova, Valentina; Zhang, Jing

    2009-02-01

    Common benchmark data sets, standardized performance metrics, and baseline algorithms have demonstrated considerable impact on research and development in a variety of application domains. These resources provide both consumers and developers of technology with a common framework to objectively compare the performance of different algorithms and algorithmic improvements. In this paper, we present such a framework for evaluating object detection and tracking in video: specifically for face, text, and vehicle objects. This framework includes the source video data, ground-truth annotations (along with guidelines for annotation), performance metrics, evaluation protocols, and tools including scoring software and baseline algorithms. For each detection and tracking task and supported domain, we developed a 50-clip training set and a 50-clip test set. Each data clip is approximately 2.5 minutes long and has been completely spatially/temporally annotated at the I-frame level. Each task/domain, therefore, has an associated annotated corpus of approximately 450,000 frames. The scope of such annotation is unprecedented and was designed to begin to support the necessary quantities of data for robust machine learning approaches, as well as a statistically significant comparison of the performance of algorithms. The goal of this work was to systematically address the challenges of object detection and tracking through a common evaluation framework that permits a meaningful objective comparison of techniques, provides the research community with sufficient data for the exploration of automatic modeling techniques, encourages the incorporation of objective evaluation into the development process, and contributes useful lasting resources of a scale and magnitude that will prove to be extremely useful to the computer vision research community for years to come.

  20. Analysis of protein glycation in human fingernail clippings with near-infrared (NIR) spectroscopy as an alternative technique for the diagnosis of diabetes mellitus.

    PubMed

    Monteyne, Tinne; Coopman, Renaat; Kishabongo, Antoine S; Himpe, Jonas; Lapauw, Bruno; Shadid, Samyah; Van Aken, Elisabeth H; Berenson, Darja; Speeckaert, Marijn M; De Beer, Thomas; Delanghe, Joris R

    2018-05-11

    Glycated keratin allows the monitoring of average tissue glucose exposure over previous weeks. In the present study, we wanted to explore if near-infrared (NIR) spectroscopy could be used as a non-invasive diagnostic tool for assessing glycation in diabetes mellitus. A total of 52 patients with diabetes mellitus and 107 healthy subjects were enrolled in this study. A limited number (n=21) of nails of healthy subjects were glycated in vitro with 0.278 mol/L, 0.556 mol/L and 0.833 mol/L glucose solution to study the effect of glucose on the nail spectrum. Consequently, the nail clippings of the patients were analyzed using a Thermo Fisher Antaris II Near-IR Analyzer Spectrometer and near infrared (NIR) chemical imaging. Spectral classification (patients with diabetes mellitus vs. healthy subjects) was performed using partial least square discriminant analysis (PLS-DA). In vitro glycation resulted in peak sharpening between 4300 and 4400 cm-1 and spectral variations at 5270 cm-1 and between 6600 and 7500 cm-1. Similar regions encountered spectral deviations during analysis of the patients' nails. Optimization of the spectral collection parameters was necessary in order to distinguish a large dataset. Spectra had to be collected at 16 cm-1, 128 scans, region 4000-7500 cm-1. Using standard normal variate, Savitsky-Golay smoothing (7 points) and first derivative preprocessing allowed for the prediction of the test set with 100% correct assignments utilizing a PLS-DA model. Analysis of protein glycation in human fingernail clippings with NIR spectroscopy could be an alternative affordable technique for the diagnosis of diabetes mellitus.

  1. 76 FR 31360 - Paper Clips From China; Scheduling of an Expedited Five-Year Review Concerning the Antidumping...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-31

    ... INTERNATIONAL TRADE COMMISSION [Investigation No. 731-TA-663 Third Review] Paper Clips From China; Scheduling of an Expedited Five-Year Review Concerning the Antidumping Duty Order on Paper Clips From China... paper clips from China would be likely to lead to continuation or recurrence of material injury within a...

  2. 76 FR 44575 - Paper Clips From the People's Republic of China: Continuation of the Antidumping Duty Order

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-07-26

    ... DEPARTMENT OF COMMERCE International Trade Administration [A-570-826] Paper Clips From the People... the antidumping duty order on paper clips from the People's Republic of China (``PRC'') would likely... of the antidumping duty order on paper clips from the PRC pursuant to section 751(c) of the Tariff...

  3. 78 FR 78319 - Media Bureau Seeks Comment on Application of the IP Closed Captioning Rules to Video Clips

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-12-26

    ... Seeks Comment on Application of the IP Closed Captioning Rules to Video Clips AGENCY: Federal... captioning of video clips delivered by Internet protocol (``IP''), including the extent to which industry has voluntarily captioned IP- delivered video clips. The Commission directed the Media Bureau to issue this...

  4. CLIPS: A tool for the development and delivery of expert systems

    NASA Technical Reports Server (NTRS)

    Riley, Gary

    1991-01-01

    The C Language Integrated Production System (CLIPS) is a forward chaining rule-based language developed by the Software Technology Branch at the Johnson Space Center. CLIPS provides a complete environment for the construction of rule-based expert systems. CLIPS was designed specifically to provide high probability, low cost, and easy integration with external systems. Other key features of CLIPS include a powerful rule syntax, an interactive development environment, high performance, extensibility, a verification/validation tool, extensive documentation, and source code availability. The current release of CLIPS, version 4.3, is being used by over 2,500 users throughout the public and private community including: all NASA sites and branches of the military, numerous Federal bureaus, government contractors, 140 universities, and many companies.

  5. Detection of third and sixth cranial nerve palsies with a novel method for eye tracking while watching a short film clip

    PubMed Central

    Samadani, Uzma; Farooq, Sameer; Ritlop, Robert; Warren, Floyd; Reyes, Marleen; Lamm, Elizabeth; Alex, Anastasia; Nehrbass, Elena; Kolecki, Radek; Jureller, Michael; Schneider, Julia; Chen, Agnes; Shi, Chen; Mendhiratta, Neil; Huang, Jason H.; Qian, Meng; Kwak, Roy; Mikheev, Artem; Rusinek, Henry; George, Ajax; Fergus, Robert; Kondziolka, Douglas; Huang, Paul P.; Smith, R. Theodore

    2015-01-01

    OBJECT Automated eye movement tracking may provide clues to nervous system function at many levels. Spatial calibration of the eye tracking device requires the subject to have relatively intact ocular motility that implies function of cranial nerves (CNs) III (oculomotor), IV (trochlear), and VI (abducent) and their associated nuclei, along with the multiple regions of the brain imparting cognition and volition. The authors have developed a technique for eye tracking that uses temporal rather than spatial calibration, enabling detection of impaired ability to move the pupil relative to normal (neurologically healthy) control volunteers. This work was performed to demonstrate that this technique may detect CN palsies related to brain compression and to provide insight into how the technique may be of value for evaluating neuropathological conditions associated with CN palsy, such as hydrocephalus or acute mass effect. METHODS The authors recorded subjects’ eye movements by using an Eyelink 1000 eye tracker sampling at 500 Hz over 200 seconds while the subject viewed a music video playing inside an aperture on a computer monitor. The aperture moved in a rectangular pattern over a fixed time period. This technique was used to assess ocular motility in 157 neurologically healthy control subjects and 12 patients with either clinical CN III or VI palsy confirmed by neuro-ophthalmological examination, or surgically treatable pathological conditions potentially impacting these nerves. The authors compared the ratio of vertical to horizontal eye movement (height/width defined as aspect ratio) in normal and test subjects. RESULTS In 157 normal controls, the aspect ratio (height/width) for the left eye had a mean value ± SD of 1.0117 ± 0.0706. For the right eye, the aspect ratio had a mean of 1.0077 ± 0.0679 in these 157 subjects. There was no difference between sexes or ages. A patient with known CN VI palsy had a significantly increased aspect ratio (1.39), whereas 2 patients with known CN III palsy had significantly decreased ratios of 0.19 and 0.06, respectively. Three patients with surgically treatable pathological conditions impacting CN VI, such as infratentorial mass effect or hydrocephalus, had significantly increased ratios (1.84, 1.44, and 1.34, respectively) relative to normal controls, and 6 patients with supratentorial mass effect had significantly decreased ratios (0.27, 0.53, 0.62, 0.45, 0.49, and 0.41, respectively). These alterations in eye tracking all reverted to normal ranges after surgical treatment of underlying pathological conditions in these 9 neurosurgical cases. CONCLUSIONS This proof of concept series of cases suggests that the use of eye tracking to detect CN palsy while the patient watches television or its equivalent represents a new capacity for this technology. It may provide a new tool for the assessment of multiple CNS functions that can potentially be useful in the assessment of awake patients with elevated intracranial pressure from hydrocephalus or trauma. PMID:25495739

  6. Detection of third and sixth cranial nerve palsies with a novel method for eye tracking while watching a short film clip.

    PubMed

    Samadani, Uzma; Farooq, Sameer; Ritlop, Robert; Warren, Floyd; Reyes, Marleen; Lamm, Elizabeth; Alex, Anastasia; Nehrbass, Elena; Kolecki, Radek; Jureller, Michael; Schneider, Julia; Chen, Agnes; Shi, Chen; Mendhiratta, Neil; Huang, Jason H; Qian, Meng; Kwak, Roy; Mikheev, Artem; Rusinek, Henry; George, Ajax; Fergus, Robert; Kondziolka, Douglas; Huang, Paul P; Smith, R Theodore

    2015-03-01

    Automated eye movement tracking may provide clues to nervous system function at many levels. Spatial calibration of the eye tracking device requires the subject to have relatively intact ocular motility that implies function of cranial nerves (CNs) III (oculomotor), IV (trochlear), and VI (abducent) and their associated nuclei, along with the multiple regions of the brain imparting cognition and volition. The authors have developed a technique for eye tracking that uses temporal rather than spatial calibration, enabling detection of impaired ability to move the pupil relative to normal (neurologically healthy) control volunteers. This work was performed to demonstrate that this technique may detect CN palsies related to brain compression and to provide insight into how the technique may be of value for evaluating neuropathological conditions associated with CN palsy, such as hydrocephalus or acute mass effect. The authors recorded subjects' eye movements by using an Eyelink 1000 eye tracker sampling at 500 Hz over 200 seconds while the subject viewed a music video playing inside an aperture on a computer monitor. The aperture moved in a rectangular pattern over a fixed time period. This technique was used to assess ocular motility in 157 neurologically healthy control subjects and 12 patients with either clinical CN III or VI palsy confirmed by neuro-ophthalmological examination, or surgically treatable pathological conditions potentially impacting these nerves. The authors compared the ratio of vertical to horizontal eye movement (height/width defined as aspect ratio) in normal and test subjects. In 157 normal controls, the aspect ratio (height/width) for the left eye had a mean value ± SD of 1.0117 ± 0.0706. For the right eye, the aspect ratio had a mean of 1.0077 ± 0.0679 in these 157 subjects. There was no difference between sexes or ages. A patient with known CN VI palsy had a significantly increased aspect ratio (1.39), whereas 2 patients with known CN III palsy had significantly decreased ratios of 0.19 and 0.06, respectively. Three patients with surgically treatable pathological conditions impacting CN VI, such as infratentorial mass effect or hydrocephalus, had significantly increased ratios (1.84, 1.44, and 1.34, respectively) relative to normal controls, and 6 patients with supratentorial mass effect had significantly decreased ratios (0.27, 0.53, 0.62, 0.45, 0.49, and 0.41, respectively). These alterations in eye tracking all reverted to normal ranges after surgical treatment of underlying pathological conditions in these 9 neurosurgical cases. This proof of concept series of cases suggests that the use of eye tracking to detect CN palsy while the patient watches television or its equivalent represents a new capacity for this technology. It may provide a new tool for the assessment of multiple CNS functions that can potentially be useful in the assessment of awake patients with elevated intracranial pressure from hydrocephalus or trauma.

  7. Effects of Sterilization Cycles on PEEK for Medical Device Application

    PubMed Central

    Yap, Wai Teng; Foo, Soo Leong; Lee, Teck Kheng

    2018-01-01

    The effects of the sterilization process have been studied on medical grade thermoplastic polyetheretherketone (PEEK). For a reusable medical device, material reliability is an important parameter to decide its lifetime, as it will be subjected to the continuous steam sterilization process. A spring nature, clip component was selected out of a newly designed medical device (patented) to perform this reliability study. This clip component was sterilized for a predetermined number of cycles (2, 4, 6, 8, 10, 20…100) at 121 °C for 30 min. A significant decrease of ~20% in the compression force of the spring was observed after 30 cycles, and a ~6% decrease in the lateral dimension of the clip was observed after 50 cycles. No further significant change in the compression force or dimension was observed for the subsequent sterilization cycles. Vickers hardness and differential scanning calorimetry (DSC) techniques were used to characterize the effects of sterilization. DSC results exhibited no significant change in the degree of cure and melting behavior of PEEK before and after the sterilization. Hardness measurement exhibited an increase of ~49% in hardness after just 20 cycles. When an unsterilized sample was heated for repetitive cycles without the presence of moisture (121 °C, 10 and 20 cycles), only ~7% of the maximum change in hardness was observed. PMID:29466289

  8. Effects of Sterilization Cycles on PEEK for Medical Device Application.

    PubMed

    Kumar, Amit; Yap, Wai Teng; Foo, Soo Leong; Lee, Teck Kheng

    2018-02-21

    The effects of the sterilization process have been studied on medical grade thermoplastic polyetheretherketone (PEEK). For a reusable medical device, material reliability is an important parameter to decide its lifetime, as it will be subjected to the continuous steam sterilization process. A spring nature, clip component was selected out of a newly designed medical device (patented) to perform this reliability study. This clip component was sterilized for a predetermined number of cycles (2, 4, 6, 8, 10, 20…100) at 121 °C for 30 min. A significant decrease of ~20% in the compression force of the spring was observed after 30 cycles, and a ~6% decrease in the lateral dimension of the clip was observed after 50 cycles. No further significant change in the compression force or dimension was observed for the subsequent sterilization cycles. Vickers hardness and differential scanning calorimetry (DSC) techniques were used to characterize the effects of sterilization. DSC results exhibited no significant change in the degree of cure and melting behavior of PEEK before and after the sterilization. Hardness measurement exhibited an increase of ~49% in hardness after just 20 cycles. When an unsterilized sample was heated for repetitive cycles without the presence of moisture (121 °C, 10 and 20 cycles), only ~7% of the maximum change in hardness was observed.

  9. Three CLIPS-based expert systems for solving engineering problems

    NASA Technical Reports Server (NTRS)

    Parkinson, W. J.; Luger, G. F.; Bretz, R. E.

    1990-01-01

    We have written three expert systems, using the CLIPS PC-based expert system shell. These three expert systems are rule based and are relatively small, with the largest containing slightly less than 200 rules. The first expert system is an expert assistant that was written to help users of the ASPEN computer code choose the proper thermodynamic package to use with their particular vapor-liquid equilibrium problem. The second expert system was designed to help petroleum engineers choose the proper enhanced oil recovery method to be used with a given reservoir. The effectiveness of each technique is highly dependent upon the reservoir conditions. The third expert system is a combination consultant and control system. This system was designed specifically for silicon carbide whisker growth. Silicon carbide whiskers are an extremely strong product used to make ceramic and metal composites. The manufacture of whiskers is a very complicated process. which to date. has defied a good mathematical model. The process was run by experts who had gained their expertise by trial and error. A system of rules was devised by these experts both for procedure setup and for the process control. In this paper we discuss the three problem areas of the design, development and evaluation of the CLIPS-based programs.

  10. Energizing Staff Development Using Film Clips: Memorable Movie Moments that Promote Reflection, Conversation, and Action

    ERIC Educational Resources Information Center

    Olsen, Walter R.; Sommers, William A.

    2005-01-01

    Video and DVD clips give participants an opportunity to explore values and ideas, learn about one another, and, in the process, build a stronger learning community. "Energizing Staff Development Using Film Clips" is a collection of film and television clips that staff developers can use to encourage discussion and reflection on pertinent, common…

  11. [Reliable fixation of cochlear implant electrode mountings in children and adults--initial experiences with a new titanium clip].

    PubMed

    Müller, J; Schön, F; Helms, J

    1998-04-01

    There is a reported 1% incidence of delayed migration of extrusions of the electrode arrays out of the cochlea. A titanium clip to fix the electrode array of the MED EL Combi 40 Cochlear Implant System is described. The clip is designed and shaped in a double U configuration. The clip material allows easy adaption to the individual anatomical situation. The clip is fixed to a bony bridge at the incus bar and fixes the electrode in a plane parallel to the chorda facial angle. It is closed around the electrode similarly to a stapes piston around the incus. Additional tests which examined the possible risk of damaging the electrode carrier and clinical findings are described. The clip was used in 23 cases with a follow-up period up to 1 year. No signs for dislocation of the electrode were found. In one revision case the clip was covered with a thin mucosal layer. The electrode array showed no signs of damage. Intraoperative findings confirmed the experimental tests on the electrode fixation. The titanium clip facilitates safe and quick fixation of the electrode array and prevents dislocation. its flexibility and shape minimizes the risk of damage.

  12. Comparison of Sonography versus Digital Breast Tomosynthesis to Locate Intramammary Marker Clips

    PubMed Central

    Schulz-Wendtland, R.; Dankerl, P.; Dilbat, G.; Bani, M.; Fasching, P. A.; Heusinger, K.; Lux, M. P.; Loehberg, C. R.; Jud, S. M.; Rauh, C.; Bayer, C. M.; Beckmann, M. W.; Wachter, D. L.; Uder, M.; Meier-Meitinger, M.; Brehm, B.

    2015-01-01

    Introduction: This study aimed to compare the accuracy of sonography versus digital breast tomosynthesis to locate intramammary marker clips placed under ultrasound guidance. Patients and Methods: Fifty patients with suspicion of breast cancer (lesion diameter less than 2 cm [cT1]) had ultrasound-guided core needle biopsy with placement of a marker clip in the center of the tumor. Intramammary marker clips were subsequently located with both sonography and digital breast tomosynthesis. Results: Sonography detected no dislocation of intrammammary marker clips in 42 of 50 patients (84 %); dislocation was reported in 8 patients (16 %) with a maximum dislocation of 7 mm along the x-, y- or z-axis. Digital breast tomosynthesis showed accurate placement without dislocation of the intramammary marker clip in 48 patients (96 %); 2 patients (4 %) had a maximum clip dislocation of 3 mm along the x-, y- or z-axis (p < 0.05). Conclusion: The use of digital breast tomosynthesis could improve the accuracy when locating intramammary marker clips compared to sonography and could, in future, be used to complement or even completely replace sonography. PMID:25684789

  13. A defect in the CLIP1 gene (CLIP-170) can cause autosomal recessive intellectual disability.

    PubMed

    Larti, Farzaneh; Kahrizi, Kimia; Musante, Luciana; Hu, Hao; Papari, Elahe; Fattahi, Zohreh; Bazazzadegan, Niloofar; Liu, Zhe; Banan, Mehdi; Garshasbi, Masoud; Wienker, Thomas F; Ropers, H Hilger; Galjart, Niels; Najmabadi, Hossein

    2015-03-01

    In the context of a comprehensive research project, investigating novel autosomal recessive intellectual disability (ARID) genes, linkage analysis based on autozygosity mapping helped identify an intellectual disability locus on Chr.12q24, in an Iranian family (LOD score = 3.7). Next-generation sequencing (NGS) following exon enrichment in this novel interval, detected a nonsense mutation (p.Q1010*) in the CLIP1 gene. CLIP1 encodes a member of microtubule (MT) plus-end tracking proteins, which specifically associates with the ends of growing MTs. These proteins regulate MT dynamic behavior and are important for MT-mediated transport over the length of axons and dendrites. As such, CLIP1 may have a role in neuronal development. We studied lymphoblastoid and skin fibroblast cell lines established from healthy and affected patients. RT-PCR and western blot analyses showed the absence of CLIP1 transcript and protein in lymphoblastoid cells derived from affected patients. Furthermore, immunofluorescence analyses showed MT plus-end staining only in fibroblasts containing the wild-type (and not the mutant) CLIP1 protein. Collectively, our data suggest that defects in CLIP1 may lead to ARID.

  14. A defect in the CLIP1 gene (CLIP-170) can cause autosomal recessive intellectual disability

    PubMed Central

    Larti, Farzaneh; Kahrizi, Kimia; Musante, Luciana; Hu, Hao; Papari, Elahe; Fattahi, Zohreh; Bazazzadegan, Niloofar; Liu, Zhe; Banan, Mehdi; Garshasbi, Masoud; Wienker, Thomas F; Ropers, H Hilger; Galjart, Niels; Najmabadi, Hossein

    2015-01-01

    In the context of a comprehensive research project, investigating novel autosomal recessive intellectual disability (ARID) genes, linkage analysis based on autozygosity mapping helped identify an intellectual disability locus on Chr.12q24, in an Iranian family (LOD score=3.7). Next-generation sequencing (NGS) following exon enrichment in this novel interval, detected a nonsense mutation (p.Q1010*) in the CLIP1 gene. CLIP1 encodes a member of microtubule (MT) plus-end tracking proteins, which specifically associates with the ends of growing MTs. These proteins regulate MT dynamic behavior and are important for MT-mediated transport over the length of axons and dendrites. As such, CLIP1 may have a role in neuronal development. We studied lymphoblastoid and skin fibroblast cell lines established from healthy and affected patients. RT-PCR and western blot analyses showed the absence of CLIP1 transcript and protein in lymphoblastoid cells derived from affected patients. Furthermore, immunofluorescence analyses showed MT plus-end staining only in fibroblasts containing the wild-type (and not the mutant) CLIP1 protein. Collectively, our data suggest that defects in CLIP1 may lead to ARID. PMID:24569606

  15. The Emotional Movie Database (EMDB): a self-report and psychophysiological study.

    PubMed

    Carvalho, Sandra; Leite, Jorge; Galdo-Álvarez, Santiago; Gonçalves, Oscar F

    2012-12-01

    Film clips are an important tool for evoking emotional responses in the laboratory. When compared with other emotionally potent visual stimuli (e.g., pictures), film clips seem to be more effective in eliciting emotions for longer periods of time at both the subjective and physiological levels. The main objective of the present study was to develop a new database of affective film clips without auditory content, based on a dimensional approach to emotional stimuli (valence, arousal and dominance). The study had three different phases: (1) the pre-selection and editing of 52 film clips (2) the self-report rating of these film clips by a sample of 113 participants and (3) psychophysiological assessment [skin conductance level (SCL) and the heart rate (HR)] on 32 volunteers. Film clips from different categories were selected to elicit emotional states from different quadrants of affective space. The results also showed that sustained exposure to the affective film clips resulted in a pattern of a SCL increase and HR deceleration in high arousal conditions (i.e., horror and erotic conditions). The resulting emotional movie database can reliably be used in research requiring the presentation of non-auditory film clips with different ratings of valence, arousal and dominance.

  16. The effect of positive and negative movie alcohol portrayals on transportation and attitude toward the movie.

    PubMed

    Koordeman, Renske; Anschutz, Doeschka J; Engels, Rutger C M E

    2014-07-01

    This study examined the effects of alcohol portrayals on transportation and attitude toward a movie. In addition, we examined whether positive and negative movie alcohol portrayals affect transportation into and attitude toward the movie. A within-subject design was used in which participants were exposed to 8 different movie clips containing alcohol (positive or negative context) or no alcohol portrayals in a controlled laboratory setting. A total of 159 college students (84 males and 75 females) ages 18 to 30 participated in the experiment. Transportation and attitude toward the movie were measured after each movie clip. Participants were more transported into and had a more positive attitude toward movie clips with alcohol portrayals compared to the same movie clips with no alcohol portrayal. In addition, participants were more transported into movie clips with negative alcohol (NA) portrayals compared to clips with positive alcohol (PA) portrayals. For attitude toward the movie, opposite results were found. Participants had a more positive attitudes toward clips with PA portrayals compared to clips with NA portrayals. The way alcohol is portrayed in movies may contribute to how people evaluate and get transported in movies. Copyright © 2014 by the Research Society on Alcoholism.

  17. Predictors of shunt-dependent hydrocephalus following aneurysmal subarachnoid hemorrhage: a pilot study in a single Egyptian institute.

    PubMed

    Aboul-Ela, Hashem M; Salah El-Din, Ahmed M; Zaater, Ahmed A; Shehab, Mohamed; El Shahawy, Ossama A

    2018-01-01

    Acute hydrocephalus can cause neurological deterioration after aneurysmal subarachnoid hemorrhage (aSAH). Predicting which patient would require shunting is challenging. This prospective study was conducted upon twenty patients who suffered acute hydrocephalus due to subarachnoid hemorrhage of ruptured aneurysms. Surgical or non-surgical management of hydrocephalus was conducted. Glasgow Coma scale (GCS) was assessed, and hydrocephalus was graded by bicaudate index. Fisher grade was determined from CT scan. Aneurysm site was determined by conventional or CT angiography. Either surgical clipping or endovascular coiling of aneurysms was performed. Initially, 3 (15%) patients had emergency CSF diversion on admission due to poor GCS on arrival. Initially, the remaining 17 patients were managed conservatively. Five patients did not require any intervention. Twelve patients had external ventricular drainage placement, 4 were weaned, and 8 failed weaning. High bicaudate index (> 0.2) correlated with shunting. Aneurysm site correlated well with shunting (ACoA or PCoA). Patients with fair GCS can be managed conservatively. Any deterioration warrants shifting to CSF diversion. Higher bicaudate index will usually need CSF diversion. The value of Fisher carries no significant value. Aneurysm location (ACoA or PCoA) correlates with an increased incidence of ventriculoperitoneal shunt placement.

  18. PCLIPS: Parallel CLIPS

    NASA Technical Reports Server (NTRS)

    Hall, Lawrence O.; Bennett, Bonnie H.; Tello, Ivan

    1994-01-01

    A parallel version of CLIPS 5.1 has been developed to run on Intel Hypercubes. The user interface is the same as that for CLIPS with some added commands to allow for parallel calls. A complete version of CLIPS runs on each node of the hypercube. The system has been instrumented to display the time spent in the match, recognize, and act cycles on each node. Only rule-level parallelism is supported. Parallel commands enable the assertion and retraction of facts to/from remote nodes working memory. Parallel CLIPS was used to implement a knowledge-based command, control, communications, and intelligence (C(sup 3)I) system to demonstrate the fusion of high-level, disparate sources. We discuss the nature of the information fusion problem, our approach, and implementation. Parallel CLIPS has also be used to run several benchmark parallel knowledge bases such as one to set up a cafeteria. Results show from running Parallel CLIPS with parallel knowledge base partitions indicate that significant speed increases, including superlinear in some cases, are possible.

  19. Short term exposure to attractive and muscular singers in music video clips negatively affects men's body image and mood.

    PubMed

    Mulgrew, K E; Volcevski-Kostas, D

    2012-09-01

    Viewing idealized images has been shown to reduce men's body satisfaction; however no research has examined the impact of music video clips. This was the first study to examine the effects of exposure to muscular images in music clips on men's body image, mood and cognitions. Ninety men viewed 5 min of clips containing scenery, muscular or average-looking singers, and completed pre- and posttest measures of mood and body image. Appearance schema activation was also measured. Men exposed to the muscular clips showed poorer posttest levels of anger, body and muscle tone satisfaction compared to men exposed to the scenery or average clips. No evidence of schema activation was found, although potential problems with the measure are noted. These preliminary findings suggest that even short term exposure to music clips can produce negative effects on men's body image and mood. Copyright © 2012 Elsevier Ltd. All rights reserved.

  20. Virus-Clip: a fast and memory-efficient viral integration site detection tool at single-base resolution with annotation capability.

    PubMed

    Ho, Daniel W H; Sze, Karen M F; Ng, Irene O L

    2015-08-28

    Viral integration into the human genome upon infection is an important risk factor for various human malignancies. We developed viral integration site detection tool called Virus-Clip, which makes use of information extracted from soft-clipped sequencing reads to identify exact positions of human and virus breakpoints of integration events. With initial read alignment to virus reference genome and streamlined procedures, Virus-Clip delivers a simple, fast and memory-efficient solution to viral integration site detection. Moreover, it can also automatically annotate the integration events with the corresponding affected human genes. Virus-Clip has been verified using whole-transcriptome sequencing data and its detection was validated to have satisfactory sensitivity and specificity. Marked advancement in performance was detected, compared to existing tools. It is applicable to versatile types of data including whole-genome sequencing, whole-transcriptome sequencing, and targeted sequencing. Virus-Clip is available at http://web.hku.hk/~dwhho/Virus-Clip.zip.

  1. CLIPS - C LANGUAGE INTEGRATED PRODUCTION SYSTEM (IBM PC VERSION)

    NASA Technical Reports Server (NTRS)

    Riley, G.

    1994-01-01

    The C Language Integrated Production System, CLIPS, is a shell for developing expert systems. It is designed to allow artificial intelligence research, development, and delivery on conventional computers. The primary design goals for CLIPS are portability, efficiency, and functionality. For these reasons, the program is written in C. CLIPS meets or outperforms most micro- and minicomputer based artificial intelligence tools. CLIPS is a forward chaining rule-based language. The program contains an inference engine and a language syntax that provide a framework for the construction of an expert system. It also includes tools for debugging an application. CLIPS is based on the Rete algorithm, which enables very efficient pattern matching. The collection of conditions and actions to be taken if the conditions are met is constructed into a rule network. As facts are asserted either prior to or during a session, CLIPS pattern-matches the number of fields. Wildcards and variables are supported for both single and multiple fields. CLIPS syntax allows the inclusion of externally defined functions (outside functions which are written in a language other than CLIPS). CLIPS itself can be embedded in a program such that the expert system is available as a simple subroutine call. Advanced features found in CLIPS version 4.3 include an integrated microEMACS editor, the ability to generate C source code from a CLIPS rule base to produce a dedicated executable, binary load and save capabilities for CLIPS rule bases, and the utility program CRSV (Cross-Reference, Style, and Verification) designed to facilitate the development and maintenance of large rule bases. Five machine versions are available. Each machine version includes the source and the executable for that machine. The UNIX version includes the source and binaries for IBM RS/6000, Sun3 series, and Sun4 series computers. The UNIX, DEC VAX, and DEC RISC Workstation versions are line oriented. The PC version and the Macintosh version each contain a windowing variant of CLIPS as well as the standard line oriented version. The mouse/window interface version for the PC works with a Microsoft compatible mouse or without a mouse. This window version uses the proprietary CURSES library for the PC, but a working executable of the window version is provided. The window oriented version for the Macintosh includes a version which uses a full Macintosh-style interface, including an integrated editor. This version allows the user to observe the changing fact base and rule activations in separate windows while a CLIPS program is executing. The IBM PC version is available bundled with CLIPSITS, The CLIPS Intelligent Tutoring System for a special combined price (COS-10025). The goal of CLIPSITS is to provide the student with a tool to practice the syntax and concepts covered in the CLIPS User's Guide. It attempts to provide expert diagnosis and advice during problem solving which is typically not available without an instructor. CLIPSITS is divided into 10 lessons which mirror the first 10 chapters of the CLIPS User's Guide. The program was developed for the IBM PC series with a hard disk. CLIPSITS is also available separately as MSC-21679. The CLIPS program is written in C for interactive execution and has been implemented on an IBM PC computer operating under DOS, a Macintosh and DEC VAX series computers operating under VMS or ULTRIX. The line oriented version should run on any computer system which supports a full (Kernighan and Ritchie) C compiler or the ANSI standard C language. CLIPS was developed in 1986 and Version 4.2 was released in July of 1988. Version 4.3 was released in June of 1989.

  2. CLIPS - C LANGUAGE INTEGRATED PRODUCTION SYSTEM (MACINTOSH VERSION)

    NASA Technical Reports Server (NTRS)

    Culbert, C.

    1994-01-01

    The C Language Integrated Production System, CLIPS, is a shell for developing expert systems. It is designed to allow artificial intelligence research, development, and delivery on conventional computers. The primary design goals for CLIPS are portability, efficiency, and functionality. For these reasons, the program is written in C. CLIPS meets or outperforms most micro- and minicomputer based artificial intelligence tools. CLIPS is a forward chaining rule-based language. The program contains an inference engine and a language syntax that provide a framework for the construction of an expert system. It also includes tools for debugging an application. CLIPS is based on the Rete algorithm, which enables very efficient pattern matching. The collection of conditions and actions to be taken if the conditions are met is constructed into a rule network. As facts are asserted either prior to or during a session, CLIPS pattern-matches the number of fields. Wildcards and variables are supported for both single and multiple fields. CLIPS syntax allows the inclusion of externally defined functions (outside functions which are written in a language other than CLIPS). CLIPS itself can be embedded in a program such that the expert system is available as a simple subroutine call. Advanced features found in CLIPS version 4.3 include an integrated microEMACS editor, the ability to generate C source code from a CLIPS rule base to produce a dedicated executable, binary load and save capabilities for CLIPS rule bases, and the utility program CRSV (Cross-Reference, Style, and Verification) designed to facilitate the development and maintenance of large rule bases. Five machine versions are available. Each machine version includes the source and the executable for that machine. The UNIX version includes the source and binaries for IBM RS/6000, Sun3 series, and Sun4 series computers. The UNIX, DEC VAX, and DEC RISC Workstation versions are line oriented. The PC version and the Macintosh version each contain a windowing variant of CLIPS as well as the standard line oriented version. The mouse/window interface version for the PC works with a Microsoft compatible mouse or without a mouse. This window version uses the proprietary CURSES library for the PC, but a working executable of the window version is provided. The window oriented version for the Macintosh includes a version which uses a full Macintosh-style interface, including an integrated editor. This version allows the user to observe the changing fact base and rule activations in separate windows while a CLIPS program is executing. The IBM PC version is available bundled with CLIPSITS, The CLIPS Intelligent Tutoring System for a special combined price (COS-10025). The goal of CLIPSITS is to provide the student with a tool to practice the syntax and concepts covered in the CLIPS User's Guide. It attempts to provide expert diagnosis and advice during problem solving which is typically not available without an instructor. CLIPSITS is divided into 10 lessons which mirror the first 10 chapters of the CLIPS User's Guide. The program was developed for the IBM PC series with a hard disk. CLIPSITS is also available separately as MSC-21679. The CLIPS program is written in C for interactive execution and has been implemented on an IBM PC computer operating under DOS, a Macintosh and DEC VAX series computers operating under VMS or ULTRIX. The line oriented version should run on any computer system which supports a full (Kernighan and Ritchie) C compiler or the ANSI standard C language. CLIPS was developed in 1986 and Version 4.2 was released in July of 1988. Version 4.3 was released in June of 1989.

  3. CLIPS - C LANGUAGE INTEGRATED PRODUCTION SYSTEM (IBM PC VERSION WITH CLIPSITS)

    NASA Technical Reports Server (NTRS)

    Riley, , .

    1994-01-01

    The C Language Integrated Production System, CLIPS, is a shell for developing expert systems. It is designed to allow artificial intelligence research, development, and delivery on conventional computers. The primary design goals for CLIPS are portability, efficiency, and functionality. For these reasons, the program is written in C. CLIPS meets or outperforms most micro- and minicomputer based artificial intelligence tools. CLIPS is a forward chaining rule-based language. The program contains an inference engine and a language syntax that provide a framework for the construction of an expert system. It also includes tools for debugging an application. CLIPS is based on the Rete algorithm, which enables very efficient pattern matching. The collection of conditions and actions to be taken if the conditions are met is constructed into a rule network. As facts are asserted either prior to or during a session, CLIPS pattern-matches the number of fields. Wildcards and variables are supported for both single and multiple fields. CLIPS syntax allows the inclusion of externally defined functions (outside functions which are written in a language other than CLIPS). CLIPS itself can be embedded in a program such that the expert system is available as a simple subroutine call. Advanced features found in CLIPS version 4.3 include an integrated microEMACS editor, the ability to generate C source code from a CLIPS rule base to produce a dedicated executable, binary load and save capabilities for CLIPS rule bases, and the utility program CRSV (Cross-Reference, Style, and Verification) designed to facilitate the development and maintenance of large rule bases. Five machine versions are available. Each machine version includes the source and the executable for that machine. The UNIX version includes the source and binaries for IBM RS/6000, Sun3 series, and Sun4 series computers. The UNIX, DEC VAX, and DEC RISC Workstation versions are line oriented. The PC version and the Macintosh version each contain a windowing variant of CLIPS as well as the standard line oriented version. The mouse/window interface version for the PC works with a Microsoft compatible mouse or without a mouse. This window version uses the proprietary CURSES library for the PC, but a working executable of the window version is provided. The window oriented version for the Macintosh includes a version which uses a full Macintosh-style interface, including an integrated editor. This version allows the user to observe the changing fact base and rule activations in separate windows while a CLIPS program is executing. The IBM PC version is available bundled with CLIPSITS, The CLIPS Intelligent Tutoring System for a special combined price (COS-10025). The goal of CLIPSITS is to provide the student with a tool to practice the syntax and concepts covered in the CLIPS User's Guide. It attempts to provide expert diagnosis and advice during problem solving which is typically not available without an instructor. CLIPSITS is divided into 10 lessons which mirror the first 10 chapters of the CLIPS User's Guide. The program was developed for the IBM PC series with a hard disk. CLIPSITS is also available separately as MSC-21679. The CLIPS program is written in C for interactive execution and has been implemented on an IBM PC computer operating under DOS, a Macintosh and DEC VAX series computers operating under VMS or ULTRIX. The line oriented version should run on any computer system which supports a full (Kernighan and Ritchie) C compiler or the ANSI standard C language. CLIPS was developed in 1986 and Version 4.2 was released in July of 1988. Version 4.3 was released in June of 1989.

  4. Neurosurgeon as innovator: William V. Cone (1897-1959).

    PubMed

    Preul, M C; Stratford, J; Bertrand, G; Feindel, W

    1993-10-01

    Neurosurgeons are well known for being productive researchers and innovators. Few, however, have possessed the prolific ingenuity of William Cone. In 1934, he and William Penfield were cofounders of the Montreal Neurological Institute where, until 1959, he filled the twin roles of neurosurgeon-in-chief and neuropathologist. Because he did not find writing easy, many of his technical inventions and refinements remained unpublished. His numerous innovations included the extensive use of twist-drill technique for biopsy, drainage for subdural hematoma and cerebral abscess, and ventriculography. In the mid-1940's, he developed power tools driven by nitrogen that led to the modern, universally used air-driven tool systems. He had a special interest in the treatment of spinal dysfunction, for which he invented the Cone-Barton skull-traction tongs along with the Cone spinal operating table. He also devised operative procedures for vertebral fracture-dislocation and craniospinal anomalies. For the maintenance of muscle tone in the paralyzed bladder, he constructed a tidal drainage system. He introduced and popularized ventriculoperitoneal shunting techniques and carried out some of the earliest experimental trails to treat brain infections with sulphonamide and antibiotic drugs. He designed his own set of surgical suction devices, bone rongeurs, and a personal suction "air-conditioning" system for each surgeon. He had a keen early interest in intracranial tumors, and also demonstrated on monkeys how subdural mass lesions caused pupillary dilation and mesial temporal lobe damage due to cerebral compression. His work for the military during World War II on effects of altitude on brain pressure remained classified for many years. The first clipping and excision of an intracranial aneurysm is attributed to Cone. Although Penfield was known as "the Chief," Cone was referred to as "the Boss." His fervent dedication to provide total care to his patients was expressed in round-the-clock vigils; he did not separate "nursing" from "surgical" care. Ultimately, Cone's driving passion for perfection led in part to his tragic death. His accomplishments, inventions, and his example as teacher and physician have become part of neurosurgery's collective legacy.

  5. Apparatus for the compact cooling of modules

    DOEpatents

    Iyengar, Madhusudan K.; Parida, Pritish R.

    2015-07-07

    An apparatus for the compact cooling of modules. The apparatus includes a clip, a first cover plate coupled to a first side of the clip, a second cover plate coupled to a second side of the clip opposite to the first side of the clip, a first frame thermally coupled to the first cover plate, and a second frame thermally coupled to the second cover plate. Each of the first frame and the second frame may include a plurality of channels for passing coolant through the first frame and the second frame, respectively. Additionally, the apparatus may further include a filler for directing coolant through the plurality of channels, and for blocking coolant from flowing along the first side of the clip and the second side of the clip.

  6. Application of air classification and formulation to manage feedstock cost, quality and availability for bioenergy

    DOE PAGES

    Thompson, Vicki S.; Lacey, Jeffrey A.; Hartley, Damon; ...

    2016-04-22

    Biomass such as agricultural residues, energy crops and yard waste has significant potential to be used as renewable feedstocks for production of fuels, chemicals and energy. However, in a given location, biomass availability, cost and quality can vary markedly. Strategies to manage these traits must be identified and implemented so that consistent low-cost and high-quality feedstocks can be delivered to biorefineries year round. In this study, we examine air classification as a method to mitigate high ash concentrations in corn stover, switchgrass, and grass clippings. Formulation techniques were then used to produce blends that met ash quality and biomass quantitymore » specifications at the lowest possible cost for biopower and biochemical conversion applications. It was found that air classification can separate the biomass into light fractions which contain concentrated amounts of elemental ash components introduced through soil contamination such as sodium, alumina, silica, iron and titania; and heavy fractions that are depleted in these components and have relatively lower total ash content. Light fractions of corn stover and grass clippings were found to be suitable for combustion applications since they had less propensity to slag than the whole biomass material. The remaining heavy fractions of corn stover or grass clippings could then be blended with switchgrass to produce blends that met the 5% total ash specifications suggested for biochemical conversions. However, ternary blends of the three feedstocks were not possible due to the high ash content of grass clippings. Lastly, it was determined that air classification by itself was not suitable to prepare these feedstocks for pyrolysis due to high ash content.« less

  7. Application of air classification and formulation to manage feedstock cost, quality and availability for bioenergy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thompson, Vicki S.; Lacey, Jeffrey A.; Hartley, Damon

    Biomass such as agricultural residues, energy crops and yard waste has significant potential to be used as renewable feedstocks for production of fuels, chemicals and energy. However, in a given location, biomass availability, cost and quality can vary markedly. Strategies to manage these traits must be identified and implemented so that consistent low-cost and high-quality feedstocks can be delivered to biorefineries year round. In this study, we examine air classification as a method to mitigate high ash concentrations in corn stover, switchgrass, and grass clippings. Formulation techniques were then used to produce blends that met ash quality and biomass quantitymore » specifications at the lowest possible cost for biopower and biochemical conversion applications. It was found that air classification can separate the biomass into light fractions which contain concentrated amounts of elemental ash components introduced through soil contamination such as sodium, alumina, silica, iron and titania; and heavy fractions that are depleted in these components and have relatively lower total ash content. Light fractions of corn stover and grass clippings were found to be suitable for combustion applications since they had less propensity to slag than the whole biomass material. The remaining heavy fractions of corn stover or grass clippings could then be blended with switchgrass to produce blends that met the 5% total ash specifications suggested for biochemical conversions. However, ternary blends of the three feedstocks were not possible due to the high ash content of grass clippings. Lastly, it was determined that air classification by itself was not suitable to prepare these feedstocks for pyrolysis due to high ash content.« less

  8. Duodenal endoscopic full-thickness resection (with video).

    PubMed

    Schmidt, Arthur; Meier, Benjamin; Cahyadi, Oscar; Caca, Karel

    2015-10-01

    Endoscopic resection of duodenal non-lifting adenomas and subepithelial tumors is challenging and harbors a significant risk of adverse events. We report on a novel technique for duodenal endoscopic full-thickness resection (EFTR) by using an over-the-scope device. Data of 4 consecutive patients who underwent duodenal EFTR were analyzed retrospectively. Main outcome measures were technical success, R0 resection, histologic confirmation of full-thickness resection, and adverse events. Resections were done with a novel, over-the-scope device (full-thickness resection device, FTRD). Four patients (median age 60 years) with non-lifting adenomas (2 patients) or subepithelial tumors (2 patients) underwent EFTR in the duodenum. All lesions could be resected successfully. Mean procedure time was 67.5 minutes (range 50-85 minutes). Minor bleeding was observed in 2 cases; blood transfusions were not required. There was no immediate or delayed perforation. Mean diameter of the resection specimen was 28.3 mm (range 22-40 mm). Histology confirmed complete (R0) full-thickness resection in 3 of 4 cases. To date, 2-month endoscopic follow-up has been obtained in 3 patients. In all cases, the over-the-scope clip was still in place and could be removed without adverse events; recurrences were not observed. EFTR in the duodenum with the FTRD is a promising technique that has the potential to spare surgical resections. Modifications of the device should be made to facilitate introduction by mouth. Prospective studies are needed to further evaluate efficacy and safety for duodenal resections. Copyright © 2015 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  9. CLIPS/Ada: An Ada-based tool for building expert systems

    NASA Technical Reports Server (NTRS)

    White, W. A.

    1990-01-01

    Clips/Ada is a production system language and a development environment. It is functionally equivalent to the CLIPS tool. CLIPS/Ada was developed in order to provide a means of incorporating expert system technology into projects where the use of the Ada language had been mandated. A secondary purpose was to glean information about the Ada language and its compilers. Specifically, whether or not the language and compilers were mature enough to support AI applications. The CLIPS/Ada tool is coded entirely in Ada and is designed to be used by Ada systems that require expert reasoning.

  10. A distributed Clips implementation: dClips

    NASA Technical Reports Server (NTRS)

    Li, Y. Philip

    1993-01-01

    A distributed version of the Clips language, dClips, was implemented on top of two existing generic distributed messaging systems to show that: (1) it is easy to create a coarse-grained parallel programming environment out of an existing language if a high level messaging system is used; and (2) the computing model of a parallel programming environment can be changed easily if we change the underlying messaging system. dClips processes were first connected with a simple master-slave model. A client-server model with intercommunicating agents was later implemented. The concept of service broker is being investigated.

  11. Using Video Prompting and Constant Time Delay to Teach an Internet Search Basic Skill to Students with Intellectual Disabilities

    ERIC Educational Resources Information Center

    Zisimopoulos, Dimitrios; Sigafoos, Jeff; Koutromanos, George

    2011-01-01

    We evaluated a video prompting and a constant time delay procedure for teaching three primary school students with moderate intellectual disabilities to access the Internet and download pictures related to participation in a classroom History project. Video clips were used as an antecedent prompt and as an error correction technique within a…

  12. A Bag Full of Newspaper Clippings and Other Tricks of the ESL Trade. TECHNIQUES.

    ERIC Educational Resources Information Center

    Minicz, Elizabeth Watson

    1985-01-01

    English as a second language (ESL) teachers find the newspaper a terrific source for easy-to-prepare reusable materials. Travel ads with coupons from the travel section can be cut out for beginning level students to complete and mail in envelopes they address. Students can find places on maps. In addition, intermediate and advanced students can…

  13. TH-B-204-01: Real-Time Tracking with Implanted Markers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xu, Q.

    Implanted markers as target surrogates have been widely used for treatment verification, as they provide safe and reliable monitoring of the inter- and intra-fractional target motion. The rapid advancement of technology requires a critical review and recommendation for the usage of implanted surrogates in current field. The symposium, also reporting an update of AAPM TG 199 - Implanted Target Surrogates for Radiation Treatment Verification, will be focusing on all clinical aspects of using the implanted target surrogates for treatment verification and related issues. A wide variety of markers available in the market will be first reviewed, including radiopaque markers, MRImore » compatible makers, non-migrating coils, surgical clips and electromagnetic transponders etc. The pros and cons of each kind will be discussed. The clinical applications of implanted surrogates will be presented based on different anatomical sites. For the lung, we will discuss gated treatments and 2D or 3D real-time fiducial tracking techniques. For the prostate, we will be focusing on 2D-3D, 3D-3D matching and electromagnetic transponder based localization techniques. For the liver, we will review techniques when patients are under gating, shallow or free breathing condition. We will review techniques when treating challenging breast cancer as deformation may occur. Finally, we will summarize potential issues related to the usage of implanted target surrogates with TG 199 recommendations. A review of fiducial migration and fiducial derived target rotation in different disease sites will be provided. The issue of target deformation, especially near the diaphragm, and related suggestions will be also presented and discussed. Learning Objectives: Knowledge of a wide variety of markers Knowledge of their application for different disease sites Understand of issues related to these applications Z. Wang: Research funding support from Brainlab AG Q. Xu: Consultant for Accuray; Q. Xu, I am a consultant for Accuray planning service.« less

  14. TH-B-204-03: TG-199: Implanted Markers for Radiation Treatment Verification

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Z.

    Implanted markers as target surrogates have been widely used for treatment verification, as they provide safe and reliable monitoring of the inter- and intra-fractional target motion. The rapid advancement of technology requires a critical review and recommendation for the usage of implanted surrogates in current field. The symposium, also reporting an update of AAPM TG 199 - Implanted Target Surrogates for Radiation Treatment Verification, will be focusing on all clinical aspects of using the implanted target surrogates for treatment verification and related issues. A wide variety of markers available in the market will be first reviewed, including radiopaque markers, MRImore » compatible makers, non-migrating coils, surgical clips and electromagnetic transponders etc. The pros and cons of each kind will be discussed. The clinical applications of implanted surrogates will be presented based on different anatomical sites. For the lung, we will discuss gated treatments and 2D or 3D real-time fiducial tracking techniques. For the prostate, we will be focusing on 2D-3D, 3D-3D matching and electromagnetic transponder based localization techniques. For the liver, we will review techniques when patients are under gating, shallow or free breathing condition. We will review techniques when treating challenging breast cancer as deformation may occur. Finally, we will summarize potential issues related to the usage of implanted target surrogates with TG 199 recommendations. A review of fiducial migration and fiducial derived target rotation in different disease sites will be provided. The issue of target deformation, especially near the diaphragm, and related suggestions will be also presented and discussed. Learning Objectives: Knowledge of a wide variety of markers Knowledge of their application for different disease sites Understand of issues related to these applications Z. Wang: Research funding support from Brainlab AG Q. Xu: Consultant for Accuray; Q. Xu, I am a consultant for Accuray planning service.« less

  15. TH-B-204-02: Application of Implanted Markers in Proton Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Park, S.

    Implanted markers as target surrogates have been widely used for treatment verification, as they provide safe and reliable monitoring of the inter- and intra-fractional target motion. The rapid advancement of technology requires a critical review and recommendation for the usage of implanted surrogates in current field. The symposium, also reporting an update of AAPM TG 199 - Implanted Target Surrogates for Radiation Treatment Verification, will be focusing on all clinical aspects of using the implanted target surrogates for treatment verification and related issues. A wide variety of markers available in the market will be first reviewed, including radiopaque markers, MRImore » compatible makers, non-migrating coils, surgical clips and electromagnetic transponders etc. The pros and cons of each kind will be discussed. The clinical applications of implanted surrogates will be presented based on different anatomical sites. For the lung, we will discuss gated treatments and 2D or 3D real-time fiducial tracking techniques. For the prostate, we will be focusing on 2D-3D, 3D-3D matching and electromagnetic transponder based localization techniques. For the liver, we will review techniques when patients are under gating, shallow or free breathing condition. We will review techniques when treating challenging breast cancer as deformation may occur. Finally, we will summarize potential issues related to the usage of implanted target surrogates with TG 199 recommendations. A review of fiducial migration and fiducial derived target rotation in different disease sites will be provided. The issue of target deformation, especially near the diaphragm, and related suggestions will be also presented and discussed. Learning Objectives: Knowledge of a wide variety of markers Knowledge of their application for different disease sites Understand of issues related to these applications Z. Wang: Research funding support from Brainlab AG Q. Xu: Consultant for Accuray; Q. Xu, I am a consultant for Accuray planning service.« less

  16. TH-B-204-00: Implanted Markers for Radiation Therapy and TG 199 Update

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    Implanted markers as target surrogates have been widely used for treatment verification, as they provide safe and reliable monitoring of the inter- and intra-fractional target motion. The rapid advancement of technology requires a critical review and recommendation for the usage of implanted surrogates in current field. The symposium, also reporting an update of AAPM TG 199 - Implanted Target Surrogates for Radiation Treatment Verification, will be focusing on all clinical aspects of using the implanted target surrogates for treatment verification and related issues. A wide variety of markers available in the market will be first reviewed, including radiopaque markers, MRImore » compatible makers, non-migrating coils, surgical clips and electromagnetic transponders etc. The pros and cons of each kind will be discussed. The clinical applications of implanted surrogates will be presented based on different anatomical sites. For the lung, we will discuss gated treatments and 2D or 3D real-time fiducial tracking techniques. For the prostate, we will be focusing on 2D-3D, 3D-3D matching and electromagnetic transponder based localization techniques. For the liver, we will review techniques when patients are under gating, shallow or free breathing condition. We will review techniques when treating challenging breast cancer as deformation may occur. Finally, we will summarize potential issues related to the usage of implanted target surrogates with TG 199 recommendations. A review of fiducial migration and fiducial derived target rotation in different disease sites will be provided. The issue of target deformation, especially near the diaphragm, and related suggestions will be also presented and discussed. Learning Objectives: Knowledge of a wide variety of markers Knowledge of their application for different disease sites Understand of issues related to these applications Z. Wang: Research funding support from Brainlab AG Q. Xu: Consultant for Accuray; Q. Xu, I am a consultant for Accuray planning service.« less

  17. Successful removal of football helmet face-mask clips after 1 season of use.

    PubMed

    Scibek, Jason S; Gatti, Joseph M; McKenzie, Jennifer I

    2012-01-01

    Whereas many researchers have assessed the ability to remove loop straps in traditional face-mask attachment systems after at least 1 season of use, research in which the effectiveness of the Riddell Quick Release (QR) Face Guard Attachment System clip after 1 season has been assessed is limited. To examine the success rate of removing the QR clips after 1 season of use at the Football Championship Subdivision level. We hypothesized that 1 season of use would negatively affect the removal rate of the QR clip but repeated clip-removal trials would improve the removal rate. Retrospective, quasi-experimental design. Controlled laboratory study. Sixty-three football helmets from a National Collegiate Athletic Association Division I university located in western Pennsylvania used during the 2008 season were tested. Three certified athletic trainers (2 men, 1 woman; age = 31.3 ± 3.06 years, time certified = 9.42 ± 2.65 years) attempted to remove the QR clips from each helmet with the tool provided by the manufacturer. Helmets then were reassembled to allow each athletic trainer to attempt clip removal. The dependent variables were total left clips removed (TCR-L), total right clips removed (TCR-R), and total clips removed (TCR). Success rate of clip removal (SRCR) also was assessed. Percentages for TCR-L, TCR-R, and TCR were 100% (189 of 189), 96.30% (182 of 189), and 98.15% (371 of 378), respectively. A paired-samples t test revealed a difference between TCR-R and TCR-L (t(188) = 2.689, P = .008, μ(d) = 0.037, 95% confidence interval [CI] = 0.064, 0.010). The percentage for SRCR was 96.30% (n = 182), whereas SRCR percentages for trials 1, 2, and 3 were 95.24% (n = 60), 98.41% (n = 62), and 95.24% (n = 60), respectively, and did not represent a difference (F(2,186) = 0.588, P = .56, 95% (CI) = 0.94, 0.99). Our results indicated favorable and consistent success rates for QR clip removal after 1 season of use. Whereas the QR clip is an advancement in face-mask technology, continued examination of this system is required to ensure the highest level of function, allowing for effective management of the helmeted athlete.

  18. Successful Removal of Football Helmet Face-Mask Clips After 1 Season of Use

    PubMed Central

    Scibek, Jason S.; Gatti, Joseph M.; McKenzie, Jennifer I.

    2012-01-01

    Context Whereas many researchers have assessed the ability to remove loop straps in traditional face-mask attachment systems after at least 1 season of use, research in which the effectiveness of the Riddell Quick Release (QR) Face Guard Attachment System clip after 1 season has been assessed is limited. Objective To examine the success rate of removing the QR clips after 1 season of use at the Football Championship Subdivision level. We hypothesized that 1 season of use would negatively affect the removal rate of the QR clip but repeated clip-removal trials would improve the removal rate. Design Retrospective, quasi-experimental design. Setting Controlled laboratory study. Patients or Other Participants Sixty-three football helmets from a National Collegiate Athletic Association Division I university located in western Pennsylvania used during the 2008 season were tested. Intervention(s) Three certified athletic trainers (2 men, 1 woman; age = 31.3 ± 3.06 years, time certified = 9.42 ± 2.65 years) attempted to remove the QR clips from each helmet with the tool provided by the manufacturer. Helmets then were reassembled to allow each athletic trainer to attempt clip removal. Main Outcome Measure(s) The dependent variables were total left clips removed (TCR-L), total right clips removed (TCR-R), and total clips removed (TCR). Success rate of clip removal (SRCR) also was assessed. Results Percentages for TCR-L, TCR-R, and TCR were 100% (189 of 189), 96.30% (182 of 189), and 98.15% (371 of 378), respectively. A paired-samples t test revealed a difference between TCR-R and TCR-L (t188 = −2.689, P = .008, μd = 0.037, 95% confidence interval [CI] = −0.064, −0.010). The percentage for SRCR was 96.30% (n = 182), whereas SRCR percentages for trials 1, 2, and 3 were 95.24% (n = 60), 98.41% (n = 62), and 95.24% (n = 60), respectively, and did not represent a difference (F2,186 = 0.588, P = .56, 95% CI = 0.94, 0.99). Conclusions Our results indicated favorable and consistent success rates for QR clip removal after 1 season of use. Whereas the QR clip is an advancement in face-mask technology, continued examination of this system is required to ensure the highest level of function, allowing for effective management of the helmeted athlete. PMID:22889659

  19. Effect of apical meristem clipping on carbon allocation and morphological development of white oak seedlings

    Treesearch

    Paul P. Kormanik; Shi-Jean S. Sung; T.L. Kormanik; Stanley J. Zarnoch

    1994-01-01

    Seedlings from three open-pollinated half-sib white oak seedlots were clipped in mid-July and their development was compared to nonclipped controls after one growing season.In general when data were analyzed by family, clipped seedlings were significantly less desirable in three to six of the eight variables tested.Numerically, in all families seedlots, the clipped...

  20. Clips as a knowledge based language

    NASA Technical Reports Server (NTRS)

    Harrington, James B.

    1987-01-01

    CLIPS is a language for writing expert systems applications on a personal or small computer. Here, the CLIPS programming language is described and compared to three other artificial intelligence (AI) languages (LISP, Prolog, and OPS5) with regard to the processing they provide for the implementation of a knowledge based system (KBS). A discussion is given on how CLIPS would be used in a control system.

Top