Sample records for surgical instruments vi

  1. Latest NASA Instrument Cost Model (NICM): Version VI

    NASA Technical Reports Server (NTRS)

    Mrozinski, Joe; Habib-Agahi, Hamid; Fox, George; Ball, Gary

    2014-01-01

    The NASA Instrument Cost Model, NICM, is a suite of tools which allow for probabilistic cost estimation of NASA's space-flight instruments at both the system and subsystem level. NICM also includes the ability to perform cost by analogy as well as joint confidence level (JCL) analysis. The latest version of NICM, Version VI, was released in Spring 2014. This paper will focus on the new features released with NICM VI, which include: 1) The NICM-E cost estimating relationship, which is applicable for instruments flying on Explorer-like class missions; 2) The new cluster analysis ability which, alongside the results of the parametric cost estimation for the user's instrument, also provides a visualization of the user's instrument's similarity to previously flown instruments; and 3) includes new cost estimating relationships for in-situ instruments.

  2. 21 CFR 870.4500 - Cardiovascular surgical instruments.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Cardiovascular surgical instruments. 870.4500... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Surgical Devices § 870.4500 Cardiovascular surgical instruments. (a) Identification. Cardiovascular surgical instruments are surgical instruments that...

  3. 21 CFR 870.4500 - Cardiovascular surgical instruments.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Cardiovascular surgical instruments. 870.4500... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Surgical Devices § 870.4500 Cardiovascular surgical instruments. (a) Identification. Cardiovascular surgical instruments are surgical instruments that...

  4. Surgical instrument similarity metrics and tray analysis for multi-sensor instrument identification

    NASA Astrophysics Data System (ADS)

    Glaser, Bernhard; Schellenberg, Tobias; Franke, Stefan; Dänzer, Stefan; Neumuth, Thomas

    2015-03-01

    A robust identification of the instrument currently used by the surgeon is crucial for the automatic modeling and analysis of surgical procedures. Various approaches for intra-operative surgical instrument identification have been presented, mostly based on radio-frequency identification (RFID) or endoscopic video analysis. A novel approach is to identify the instruments on the instrument table of the scrub nurse with a combination of video and weight information. In a previous article, we successfully followed this approach and applied it to multiple instances of an ear, nose and throat (ENT) procedure and the surgical tray used therein. In this article, we present a metric for the suitability of the instruments of a surgical tray for identification by video and weight analysis and apply it to twelve trays of four different surgical domains (abdominal surgery, neurosurgery, orthopedics and urology). The used trays were digitized at the central sterile services department of the hospital. The results illustrate that surgical trays differ in their suitability for the approach. In general, additional weight information can significantly contribute to the successful identification of surgical instruments. Additionally, for ten different surgical instruments, ten exemplars of each instrument were tested for their weight differences. The samples indicate high weight variability in instruments with identical brand and model number. The results present a new metric for approaches aiming towards intra-operative surgical instrument detection and imply consequences for algorithms exploiting video and weight information for identification purposes.

  5. Dermatologic Surgical Instruments: A History and Review.

    PubMed

    Gandhi, Sumul A; Kampp, Jeremy T

    2017-01-01

    Dermatologic surgery requires precision and accuracy given the delicate nature of procedures performed. The use of the most appropriate instrument for each action helps optimize both functionality and cosmetic outcome. To review the history of surgical instruments used in dermatology, with a focus on mechanism and evolution to the instruments that are used in current practice. A comprehensive literature search was conducted via textbook and journal research for historic references while review of current references was conducted online using multiple search engines and PubMed. There are a number of articles that review instruments in dermatology, but this article adds a unique perspective in classifying their evolution, while also presenting them as levers that serve to increase human dexterity during the course of surgery. Surgical instruments allow fine manipulation of tissue, which in turn produces optimal outcomes. Surgical tools have been around since the dawn of man, and their evolution parallels the extent to which human civilization has specialized over time. This article describes the evolution of instruments from the general surgical armamentaria to the specialized tools that are used today.

  6. Comparing surgical trays with redundant instruments with trays with reduced instruments: a cost analysis

    PubMed Central

    John-Baptiste, A.; Sowerby, L.J.; Chin, C.J.; Martin, J.; Rotenberg, B.W.

    2016-01-01

    Background: When prearranged standard surgical trays contain instruments that are repeatedly unused, the redundancy can result in unnecessary health care costs. Our objective was to estimate potential savings by performing an economic evaluation comparing the cost of surgical trays with redundant instruments with surgical trays with reduced instruments ("reduced trays"). Methods: We performed a cost-analysis from the hospital perspective over a 1-year period. Using a mathematical model, we compared the direct costs of trays containing redundant instruments to reduced trays for 5 otolaryngology procedures. We incorporated data from several sources including local hospital data on surgical volume, the number of instruments on redundant and reduced trays, wages of personnel and time required to pack instruments. From the literature, we incorporated instrument depreciation costs and the time required to decontaminate an instrument. We performed 1-way sensitivity analyses on all variables, including surgical volume. Costs were estimated in 2013 Canadian dollars. Results: The cost of redundant trays was $21 806 and the cost of reduced trays was $8803, for a 1-year cost saving of $13 003. In sensitivity analyses, cost savings ranged from $3262 to $21 395, based on the surgical volume at the institution. Variation in surgical volume resulted in a wider range of estimates, with a minimum of $3253 for low-volume to a maximum of $52 012 for high-volume institutions. Interpretation: Our study suggests moderate savings may be achieved by reducing surgical tray redundancy and, if applied to other surgical specialties, may result in savings to Canadian health care systems. PMID:27975045

  7. Comparing surgical trays with redundant instruments with trays with reduced instruments: a cost analysis.

    PubMed

    John-Baptiste, A; Sowerby, L J; Chin, C J; Martin, J; Rotenberg, B W

    2016-01-01

    When prearranged standard surgical trays contain instruments that are repeatedly unused, the redundancy can result in unnecessary health care costs. Our objective was to estimate potential savings by performing an economic evaluation comparing the cost of surgical trays with redundant instruments with surgical trays with reduced instruments ("reduced trays"). We performed a cost-analysis from the hospital perspective over a 1-year period. Using a mathematical model, we compared the direct costs of trays containing redundant instruments to reduced trays for 5 otolaryngology procedures. We incorporated data from several sources including local hospital data on surgical volume, the number of instruments on redundant and reduced trays, wages of personnel and time required to pack instruments. From the literature, we incorporated instrument depreciation costs and the time required to decontaminate an instrument. We performed 1-way sensitivity analyses on all variables, including surgical volume. Costs were estimated in 2013 Canadian dollars. The cost of redundant trays was $21 806 and the cost of reduced trays was $8803, for a 1-year cost saving of $13 003. In sensitivity analyses, cost savings ranged from $3262 to $21 395, based on the surgical volume at the institution. Variation in surgical volume resulted in a wider range of estimates, with a minimum of $3253 for low-volume to a maximum of $52 012 for high-volume institutions. Our study suggests moderate savings may be achieved by reducing surgical tray redundancy and, if applied to other surgical specialties, may result in savings to Canadian health care systems.

  8. Latest trends in craniomaxillofacial surgical instrumentation.

    PubMed

    Yim, Michael; Demke, Joshua

    2012-08-01

    To review the past year's literature regarding recent innovations in surgical instrumentation for craniomaxillofacial surgery. Current advances in surgical instrumentation have led to many improvements in the field, allowing greater visualization and precision both before and during procedures. One of the common goals is to achieve excellent outcomes with minimal complications, while at the same time minimizing invasiveness of surgery. Highlighted innovations include greater capacities for acquisition of data, leading to improved imaging modalities and expansion of computer-assisted surgical techniques; continued developments in biomaterials used in various reconstructions; and novel uses of bone cutting and bone fixation instrumentation. Technology in the field of craniomaxillofacial surgery is developing rapidly, leading to novel instrumentation being utilized across a broad spectrum of areas. Published data have been encouraging to date, indicating an ever increasing adaptation of these innovations in clinical practice. Future efforts need to focus on cost-benefit analysis and constructing larger-scale studies to better understand effectiveness and patient outcomes.

  9. Management of surgical instruments with radio frequency identification tags.

    PubMed

    Kusuda, Kaori; Yamashita, Kazuhiko; Ohnishi, Akiko; Tanaka, Kiyohito; Komino, Masaru; Honda, Hiroshi; Tanaka, Shinichi; Okubo, Takashi; Tripette, Julien; Ohta, Yuji

    2016-01-01

    To prevent malpractices, medical staff has adopted inventory time-outs and/or checklists. Accurate inventory and maintenance of surgical instruments decreases the risk of operating room miscounting and malfunction. In our previous study, an individual management of surgical instruments was accomplished using Radio Frequency Identification (RFID) tags. The purpose of this paper is to evaluate a new management method of RFID-tagged instruments. The management system of RFID-tagged surgical instruments was used for 27 months in clinical areas. In total, 13 study participants assembled surgical trays in the central sterile supply department. While using the management system, trays were assembled 94 times. During this period, no assembly errors occurred. An instrument malfunction had occurred after the 19th, 56th, and 73 th uses, no malfunction caused by the RFID tags, and usage history had been recorded. Additionally, the time it took to assemble surgical trays was recorded, and the long-term usability of the management system was evaluated. The system could record the number of uses and the defective history of each surgical instrument. In addition, the history of the frequency of instruments being transferred from one tray to another was recorded. The results suggest that our system can be used to manage instruments safely. Additionally, the management system was acquired of the learning effect and the usability on daily maintenance. This finding suggests that the management system examined here ensures surgical instrument and tray assembly quality.

  10. Nickel release from surgical instruments and operating room equipment.

    PubMed

    Boyd, Anne H; Hylwa, Sara A

    2018-04-15

    Background There has been no systematic study assessing nickel release from surgical instruments and equipment used within the operating suite. This equipment represents important potential sources of exposure for nickel-sensitive patients and hospital staff. To investigate nickel release from commonly used surgical instruments and operating room equipment. Using the dimethylglyoxime nickel spot test, a variety of surgical instruments and operating room equipment were tested for nickel release at our institution. Of the 128 surgical instruments tested, only 1 was positive for nickel release. Of the 43 operating room items tested, 19 were positive for nickel release, 7 of which have the potential for direct contact with patients and/or hospital staff. Hospital systems should be aware of surgical instruments and operating room equipment as potential sources of nickel exposure.

  11. Tracking multiple surgical instruments in a near-infrared optical system.

    PubMed

    Cai, Ken; Yang, Rongqian; Lin, Qinyong; Wang, Zhigang

    2016-12-01

    Surgical navigation systems can assist doctors in performing more precise and more efficient surgical procedures to avoid various accidents. The near-infrared optical system (NOS) is an important component of surgical navigation systems. However, several surgical instruments are used during surgery, and effectively tracking all of them is challenging. A stereo matching algorithm using two intersecting lines and surgical instrument codes is proposed in this paper. In our NOS, the markers on the surgical instruments can be captured by two near-infrared cameras. After automatically searching and extracting their subpixel coordinates in the left and right images, the coordinates of the real and pseudo markers are determined by the two intersecting lines. Finally, the pseudo markers are removed to achieve accurate stereo matching by summing the codes for the distances between a specific marker with the other two markers on the surgical instrument. Experimental results show that the markers on the different surgical instruments can be automatically and accurately recognized. The NOS can accurately track multiple surgical instruments.

  12. Disposable laparoscopic surgical instruments and the economic effects of repackaging.

    PubMed

    Takeuchi, Hiroyuki; Kikuchi, Iwaho; Kitade, Mari; Kumakiri, Jun; Kinoshita, Katsuyuki; Takehiro, Yuka; Tanimura, Emiko

    2005-04-01

    The purpose of this study was to evaluate the economic effects of repackaging disposable laparoscopic surgical instruments. We repacked a total of 28 disposable instruments for gynecologic laparoscopic surgery into one package. The time of preparation of surgical instruments, the amount of medical waste, and other economic effects were compared before and after the repackaging of disposable instruments. The time required for the preparation of surgical instruments was shortened by 22 minutes per operation, and medical waste decreased by 400 g, by repackaging the instruments, resulting in an estimated direct economic saving of $10,000 per year. Indirect economic effects might include savings due to a reduced inventory of surgical instruments and simplified cost-accounting for each operation. It is likely that preparation for surgery can be significantly improved and the cost reduced by repackaging the laparoscopic surgical instruments.

  13. Surgical Instrument Restraint in Weightlessness

    NASA Technical Reports Server (NTRS)

    Campbell, Mark R.; Dawson, David L.; Melton, Shannon; Hooker, Dona; Cantu, Hilda

    2000-01-01

    Performing a surgical procedure during spaceflight will become more likely with longer duration missions in the near future. Minimal surgical capability has been present on previous missions as the definitive medical care time was short and the likelihood of surgical events too low to justify surgical hardware availability. Early demonstrations of surgical procedures in the weightlessness of parabolic flight indicated the need for careful logistical planning and restraint of surgical hardware. The consideration of human ergonomics also has more impact in weightlessness than in the conventionall-g environment. Three methods of surgical instrument restraint - a Minor Surgical Kit (MSK), a Surgical Restraint Scrub Suit (SRSS), and a Surgical Tray (ST) were evaluated in parabolic flight surgical procedures. The Minor Surgical Kit was easily stored, easily deployed, and demonstrated the best ability to facilitate a surgical procedure in weightlessness. Important factors in this surgical restraint system include excellent organization of supplies, ability to maintain sterility, accessibility while providing secure restraint, ability to dispose of sharp items and biological trash, and ergonomical efficiency.

  14. Evaluation of Sensor Configurations for Robotic Surgical Instruments.

    PubMed

    Gómez-de-Gabriel, Jesús M; Harwin, William

    2015-10-27

    Designing surgical instruments for robotic-assisted minimally-invasive surgery (RAMIS) is challenging due to constraints on the number and type of sensors imposed by considerations such as space or the need for sterilization. A new method for evaluating the usability of virtual teleoperated surgical instruments based on virtual sensors is presented. This method uses virtual prototyping of the surgical instrument with a dual physical interaction, which allows testing of different sensor configurations in a real environment. Moreover, the proposed approach has been applied to the evaluation of prototypes of a two-finger grasper for lump detection by remote pinching. In this example, the usability of a set of five different sensor configurations, with a different number of force sensors, is evaluated in terms of quantitative and qualitative measures in clinical experiments with 23 volunteers. As a result, the smallest number of force sensors needed in the surgical instrument that ensures the usability of the device can be determined. The details of the experimental setup are also included.

  15. Evaluation of Sensor Configurations for Robotic Surgical Instruments

    PubMed Central

    Gómez-de-Gabriel, Jesús M.; Harwin, William

    2015-01-01

    Designing surgical instruments for robotic-assisted minimally-invasive surgery (RAMIS) is challenging due to constraints on the number and type of sensors imposed by considerations such as space or the need for sterilization. A new method for evaluating the usability of virtual teleoperated surgical instruments based on virtual sensors is presented. This method uses virtual prototyping of the surgical instrument with a dual physical interaction, which allows testing of different sensor configurations in a real environment. Moreover, the proposed approach has been applied to the evaluation of prototypes of a two-finger grasper for lump detection by remote pinching. In this example, the usability of a set of five different sensor configurations, with a different number of force sensors, is evaluated in terms of quantitative and qualitative measures in clinical experiments with 23 volunteers. As a result, the smallest number of force sensors needed in the surgical instrument that ensures the usability of the device can be determined. The details of the experimental setup are also included. PMID:26516863

  16. Sensorization of a surgical robotic instrument for force sensing

    NASA Astrophysics Data System (ADS)

    Shahzada, Kaspar S.; Yurkewich, Aaron; Xu, Ran; Patel, Rajni V.

    2016-03-01

    This paper presents the development and application of an approach for sensorizing a surgical robotic instrument for two degree-of-freedom (DOF) lateral force sensing. The sensorized instrument is compatible with the da Vinci® Surgical System and can be used for skills assessment and force control in specific surgical tasks. The sensing technology utilizes a novel layout of four fiber Bragg grating (FBG) sensors attached to the shaft of a da Vinci® surgical instrument. The two cross-section layout is insensitive to error caused by combined force and torque loads, and the orientation of the sensors minimizes the condition number of the instrument's compliance matrix. To evaluate the instrument's sensing capabilities, its performance was tested using a commercially available force-torque sensor, and showed a resolution of 0.05N at 1 kHz sampling rate. The performance of the sensorized instrument was evaluated by performing three surgical tasks on phantom tissue using the da Vinci® system with the da Vinci Research Kit (dVRK): tissue palpation, knot tightening during suturing and Hem-O-Lok® tightening during knotless suturing. The tasks were designed to demonstrate the robustness of the sensorized force measurement approach. The paper reports the results of further evaluation by a group of expert and novice surgeons performing the three tasks mentioned above.

  17. 21 CFR 878.4800 - Manual surgical instrument for general use.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Manual surgical instrument for general use. 878.4800 Section 878.4800 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4800 Manual surgical instrument for general use. (a)...

  18. Gastroenterology-Urology Devices; Manual Gastroenterology-Urology Surgical Instruments and Accessories. Final rule; technical amendment.

    PubMed

    2017-03-01

    The Food and Drug Administration (FDA) is amending the identification of manual gastroenterology-urology surgical instruments and accessories to reflect that the device does not include specialized surgical instrumentation for use with urogyencologic surgical mesh specifically intended for use as an aid in the insertion, placement, fixation, or anchoring of surgical mesh during urogynecologic procedures ("specialized surgical instrumentation for use with urogynecologic surgical mesh"). These amendments are being made to reflect changes made in the recently issued final reclassification order for specialized surgical instrumentation for use with urogynecologic surgical mesh.

  19. Compact tracking of surgical instruments through structured markers.

    PubMed

    Alberto Borghese, N; Frosio, I

    2013-07-01

    Virtual and augmented reality surgery calls for reliable and efficient tracking of the surgical instruments in the virtual or real operating theatre. The most diffused approach uses three or more not aligned markers, attached to each instrument and surveyed by a set of cameras. However, the structure required to carry the markers does modify the instrument's mass distribution and can interfere with surgeon movements. To overcome these problems, we propose here a new methodology, based on structured markers, to compute the six degrees of freedom of a surgical instrument. Two markers are attached on the instrument axis and one of them has a stripe painted over its surface. We also introduce a procedure to compute with high accuracy the markers center on the cameras image, even when partially occluded by the instrument's axis or by other structures. Experimental results demonstrate the reliability and accuracy of the proposed approach. The introduction of structured passive markers can open new possibilities to accurate tracking, combining markers detection with real-time image processing.

  20. Corrosion protection of reusable surgical instruments.

    PubMed

    Shah, Sadiq; Bernardo, Mildred

    2002-01-01

    To understand the corrosion properties of surgical scissors, 416 stainless steel disks and custom electrodes were used as simulated surfaces under various conditions. These simulated surfaces were exposed to tap water and 400-ppm synthetic hard water as Ca2CO3 under different conditions. The samples were evaluated by various techniques for corrosion potential and the impact of environmental conditions on the integrity of the passive film. The electrodes were used to monitor the corrosion behavior by potentiodynamic polarization technique in water both in the presence and absence of a cleaning product. The surface topography of the 416 stainless steel disks was characterized by visual observations and scanning electron microscopy (SEM), and the surface chemistry of the passive film on the surface of the scissors was characterized by x-ray photoelectron spectroscopy (XPS). The results suggest that surgical instruments made from 416 stainless steel are not susceptible to uniform corrosion; however, they do undergo localized corrosion. The use of suitable cleaning products can offer protection against localized corrosion during the cleaning step. More importantly, the use of potentiodynamic polarization techniques allowed for a quick and convenient approach to evaluate the corrosion properties of surgical instruments under a variety of simulated-use environmental conditions.

  1. Three-dimensional printing surgical instruments: are we there yet?

    PubMed

    Rankin, Timothy M; Giovinco, Nicholas A; Cucher, Daniel J; Watts, George; Hurwitz, Bonnie; Armstrong, David G

    2014-06-15

    The applications for rapid prototyping have expanded dramatically over the last 20 y. In recent years, additive manufacturing has been intensely investigated for surgical implants, tissue scaffolds, and organs. There is, however, scant literature to date that has investigated the viability of three-dimensional (3D) printing of surgical instruments. Using a fused deposition modeling printer, an Army/Navy surgical retractor was replicated from polylactic acid (PLA) filament. The retractor was sterilized using standard Food and Drug Administration approved glutaraldehyde protocols, tested for bacteria by polymerase chain reaction, and stressed until fracture to determine if the printed instrument could tolerate force beyond the demands of an operating room (OR). Printing required roughly 90 min. The instrument tolerated 13.6 kg of tangential force before failure, both before and after exposure to the sterilant. Freshly extruded PLA from the printer was sterile and produced no polymerase chain reaction product. Each instrument weighed 16 g and required only $0.46 of PLA. Our estimates place the cost per unit of a 3D-printed retractor to be roughly 1/10th the cost of a stainless steel instrument. The PLA Army/Navy retractor is strong enough for the demands of the OR. Freshly extruded PLA in a clean environment, such as an OR, would produce a sterile ready-to-use instrument. Because of the unprecedented accessibility of 3D printing technology world wide and the cost efficiency of these instruments, there are far reaching implications for surgery in some underserved and less developed parts of the world. Copyright © 2014 Elsevier Inc. All rights reserved.

  2. 3D printing surgical instruments: Are we there yet?

    PubMed Central

    Rankin, Timothy M.; Giovinco, Nicholas A.; Cucher, Daniel J.; Watts, George; Hurwitz, Bonnie; Armstrong, David G.

    2015-01-01

    Background The applications for rapid prototyping have expanded dramatically over the last 20 years. In recent years, additive manufacturing has been intensely investigated for surgical implants, tissue scaffolds, and organs. There is, however, scant literature to date that has investigated the viability of 3D printing of surgical instruments. Materials and Methods Using a fused deposition manufacturing (FDM) printer, an army/ navy surgical retractor was replicated from polylactic acid (PLA) filament. The retractor was sterilized using standard FDA approved glutaraldehyde protocols, tested for bacteria by PCR, and stressed until fracture in order to determine if the printed instrument could tolerate force beyond the demands of an operating room. Results Printing required roughly 90 minutes. The instrument tolerated 13.6 kg of tangential force before failure, both before and after exposure to the sterilant. Freshly extruded PLA from the printer was sterile and produced no PCR product. Each instrument weighed 16g and required only $0.46 of PLA. Conclusions Our estimates place the cost per unit of a 3D printed retractor to be roughly 1/10th the cost of a stainless steel instrument. The PLA Army/ Navy is strong enough for the demands of the operating room. Freshly extruded PLA in a clean environment, such as an OR, would produce a sterile, ready to use instrument. Due to the unprecedented accessibility of 3D printing technology world wide, and the cost efficiency of these instruments, there are far reaching implications for surgery in some underserved and less developed parts of the world. PMID:24721602

  3. 21 CFR 888.4580 - Sonic surgical instrument and accessories/attachments.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Sonic surgical instrument and accessories/attachments. 888.4580 Section 888.4580 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Surgical Devices § 888.4580 Sonic surgical...

  4. 21 CFR 888.4580 - Sonic surgical instrument and accessories/attachments.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Sonic surgical instrument and accessories/attachments. 888.4580 Section 888.4580 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Surgical Devices § 888.4580 Sonic surgical...

  5. 21 CFR 888.4580 - Sonic surgical instrument and accessories/attachments.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Sonic surgical instrument and accessories/attachments. 888.4580 Section 888.4580 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Surgical Devices § 888.4580 Sonic surgical...

  6. 21 CFR 888.4580 - Sonic surgical instrument and accessories/attachments.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Sonic surgical instrument and accessories/attachments. 888.4580 Section 888.4580 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Surgical Devices § 888.4580 Sonic surgical...

  7. 21 CFR 888.4580 - Sonic surgical instrument and accessories/attachments.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Sonic surgical instrument and accessories/attachments. 888.4580 Section 888.4580 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Surgical Devices § 888.4580 Sonic surgical...

  8. 3D Printed Surgical Instruments Evaluated by a Simulated Crew of a Mars Mission.

    PubMed

    Wong, Julielynn Y; Pfahnl, Andreas C

    2016-09-01

    The first space-based fused deposition modeling (FDM) 3D printer became operational in 2014. This study evaluated whether Mars simulation crewmembers of the Hawai'i Space Exploration Analog and Simulation (HI-SEAS) II mission with no prior surgical experience could utilize acrylonitrile butadiene styrene (ABS) thermoplastic surgical instruments FDM 3D printed on Earth to complete simulated surgical tasks. This study sought to examine the feasibility of using 3D printed surgical tools when the primary crew medical officer is incapacitated and the back-up crew medical officer must conduct a surgical procedure during a simulated extended space mission. During a 4 mo duration ground-based analog mission, five simulation crewmembers with no prior surgical experience completed 16 timed sets of simulated prepping, draping, incising, and suturing tasks to evaluate the relative speed of using four ABS thermoplastic instruments printed on Earth compared to conventional instruments. All four simulated surgical tasks were successfully performed using 3D printed instruments by Mars simulation crewmembers with no prior surgical experience. There was no substantial difference in time to completion of simulated tasks with control vs. 3D printed sponge stick, towel clamp, scalpel handle, and toothed forceps. These limited findings support further investigation into the creation of an onboard digital catalog of validated 3D printable surgical instrument design files to support autonomous, crew-administered healthcare on Mars missions. Future work could include addressing sterility, biocompatibility, and having astronaut crew medical officers test a wider range of surgical instruments printed in microgravity during actual surgical procedures. Wong JY, Pfahnl AC. 3D printed surgical instruments evaluated by a simulated crew of a Mars mission. Aerosp Med Hum Perform. 2016; 87(9):806-810.

  9. 3D Printed Surgical Instruments: The Design and Fabrication Process.

    PubMed

    George, Mitchell; Aroom, Kevin R; Hawes, Harvey G; Gill, Brijesh S; Love, Joseph

    2017-01-01

    3D printing is an additive manufacturing process allowing the creation of solid objects directly from a digital file. We believe recent advances in additive manufacturing may be applicable to surgical instrument design. This study investigates the feasibility, design and fabrication process of usable 3D printed surgical instruments. The computer-aided design package SolidWorks (Dassault Systemes SolidWorks Corp., Waltham MA) was used to design a surgical set including hemostats, needle driver, scalpel handle, retractors and forceps. These designs were then printed on a selective laser sintering (SLS) Sinterstation HiQ (3D Systems, Rock Hill SC) using DuraForm EX plastic. The final printed products were evaluated by practicing general surgeons for ergonomic functionality and performance, this included simulated surgery and inguinal hernia repairs on human cadavers. Improvements were identified and addressed by adjusting design and build metrics. Repeated manufacturing processes and redesigns led to the creation of multiple functional and fully reproducible surgical sets utilizing the user feedback of surgeons. Iterative cycles including design, production and testing took an average of 3 days. Each surgical set was built using the SLS Sinterstation HiQ with an average build time of 6 h per set. Functional 3D printed surgical instruments are feasible. Advantages compared to traditional manufacturing methods include no increase in cost for increased complexity, accelerated design to production times and surgeon specific modifications.

  10. Recent technological advancements in laparoscopic surgical instruments

    NASA Astrophysics Data System (ADS)

    Subido, Edwin D. C.; Pacis, Danica Mitch M.; Bugtai, Nilo T.

    2018-02-01

    Laparoscopy was a progressive step to advancing surgical procedures as it minimised the scars left on the body after surgery, compared to traditional open surgery. Many years later, single-incision laparoscopic surgery (SILS) was created where, instead of having multiple incisions, only one incision is made or multiple small incisions in one location. SILS, or laparoendoscopic single-site surgery (LESS), may produce lesser scars but drawbacks for the surgeons are still present. This paper aims to present related literature of the recent technological developments in laparoscopic tools and procedure particularly in the vision system, handheld instruments. Tech advances in LESS will also be shown. Furthermore, this review intends to give an update on what has been going on in the surgical robot market and state which companies are interested and are developing robotic systems for commercial use to challenge Intuitive Surgical's da Vinci Surgical System that currently dominates the market.

  11. Infections and exposures: reported incidents associated with unsuccessful decontamination of reusable surgical instruments.

    PubMed

    Southworth, P M

    2014-11-01

    Reusable surgical instruments provide a potential route for the transmission of pathogenic agents between patients in healthcare facilities. As such, the decontamination process between uses is a vital component in the prevention of healthcare-associated infections. This article reviews reported outbreaks and incidents associated with inappropriate, inadequate, or unsuccessful decontamination of surgical instruments, indicating potential pitfalls of decontamination practices worldwide. To the author's knowledge, this is the first review of surgical instrument decontamination failures. Databases of medical literature, Medline and Embase, were searched systematically. Articles detailing incidents associated with unsuccessful decontamination of surgical instruments were identified. Twenty-one articles were identified reporting incidents associated with failures in decontamination. A large proportion of incidents involved the attempted disinfection, rather than sterilization, of surgical instruments (43% of articles), counter to a number of national guidelines. Instruments used in eye surgery were most frequently reported to be associated with decontamination failures (29% of articles). Of the few articles detailing potential or confirmed pathogenic transmission, Pseudomonas aeruginosa and Mycobacterium spp. were most represented. One incident of possible variant Creutzfeldt-Jakob disease transmission was also identified. Limitations of analysing only published incidents mean that the likelihood of under-reporting (including reluctance to publish failure) must be considered. Despite these limitations, the small number of articles identified suggests a relatively low risk of cross-infection through reusable surgical instruments when cleaning/sterilization procedures are adhered to. The diverse nature of reported incidents also suggests that failures are not systemic. Copyright © 2014 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  12. Comparison of patient-specific instruments with standard surgical instruments in determining glenoid component position: a randomized prospective clinical trial.

    PubMed

    Hendel, Michael D; Bryan, Jason A; Barsoum, Wael K; Rodriguez, Eric J; Brems, John J; Evans, Peter J; Iannotti, Joseph P

    2012-12-05

    Glenoid component malposition for anatomic shoulder replacement may result in complications. The purpose of this study was to define the efficacy of a new surgical method to place the glenoid component. Thirty-one patients were randomized for glenoid component placement with use of either novel three-dimensional computed tomographic scan planning software combined with patient-specific instrumentation (the glenoid positioning system group), or conventional computed tomographic scan, preoperative planning, and surgical technique, utilizing instruments provided by the implant manufacturer (the standard surgical group). The desired position of the component was determined preoperatively. Postoperatively, a computed tomographic scan was used to define and compare the actual implant location with the preoperative plan. In the standard surgical group, the average preoperative glenoid retroversion was -11.3° (range, -39° to 17°). In the glenoid positioning system group, the average glenoid retroversion was -14.8° (range, -27° to 7°). When the standard surgical group was compared with the glenoid positioning system group, patient-specific instrumentation technology significantly decreased (p < 0.05) the average deviation of implant position for inclination and medial-lateral offset. Overall, the average deviation in version was 6.9° in the standard surgical group and 4.3° in the glenoid positioning system group. The average deviation in inclination was 11.6° in the standard surgical group and 2.9° in the glenoid positioning system group. The greatest benefit of patient-specific instrumentation was observed in patients with retroversion in excess of 16°; the average deviation was 10° in the standard surgical group and 1.2° in the glenoid positioning system group (p < 0.001). Preoperative planning and patient-specific instrumentation use resulted in a significant improvement in the selection and use of the optimal type of implant and a significant reduction in

  13. Automated processing of endoscopic surgical instruments.

    PubMed

    Roth, K; Sieber, J P; Schrimm, H; Heeg, P; Buess, G

    1994-10-01

    This paper deals with the requirements for automated processing of endoscopic surgical instruments. After a brief analysis of the current problems, solutions are discussed. Test-procedures have been developed to validate the automated processing, so that the cleaning results are guaranteed and reproducable. Also a device for testing and cleaning was designed together with Netzsch Newamatic and PCI, called TC-MIC, to automate processing and reduce manual work.

  14. Varying ultrasound power level to distinguish surgical instruments and tissue.

    PubMed

    Ren, Hongliang; Anuraj, Banani; Dupont, Pierre E

    2018-03-01

    We investigate a new framework of surgical instrument detection based on power-varying ultrasound images with simple and efficient pixel-wise intensity processing. Without using complicated feature extraction methods, we identified the instrument with an estimated optimal power level and by comparing pixel values of varying transducer power level images. The proposed framework exploits the physics of ultrasound imaging system by varying the transducer power level to effectively distinguish metallic surgical instruments from tissue. This power-varying image-guidance is motivated from our observations that ultrasound imaging at different power levels exhibit different contrast enhancement capabilities between tissue and instruments in ultrasound-guided robotic beating-heart surgery. Using lower transducer power levels (ranging from 40 to 75% of the rated lowest ultrasound power levels of the two tested ultrasound scanners) can effectively suppress the strong imaging artifacts from metallic instruments and thus, can be utilized together with the images from normal transducer power levels to enhance the separability between instrument and tissue, improving intraoperative instrument tracking accuracy from the acquired noisy ultrasound volumetric images. We performed experiments in phantoms and ex vivo hearts in water tank environments. The proposed multi-level power-varying ultrasound imaging approach can identify robotic instruments of high acoustic impedance from low-signal-to-noise-ratio ultrasound images by power adjustments.

  15. 21 CFR 878.4820 - Surgical instrument motors and accessories/attachments.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Surgical instrument motors and accessories/attachments. 878.4820 Section 878.4820 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878...

  16. 21 CFR 878.4820 - Surgical instrument motors and accessories/attachments.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Surgical instrument motors and accessories/attachments. 878.4820 Section 878.4820 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878...

  17. 21 CFR 878.4820 - Surgical instrument motors and accessories/attachments.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Surgical instrument motors and accessories/attachments. 878.4820 Section 878.4820 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878...

  18. 21 CFR 878.4820 - Surgical instrument motors and accessories/attachments.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Surgical instrument motors and accessories/attachments. 878.4820 Section 878.4820 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878...

  19. 21 CFR 878.4820 - Surgical instrument motors and accessories/attachments.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Surgical instrument motors and accessories/attachments. 878.4820 Section 878.4820 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878...

  20. 21 CFR 878.4800 - Manual surgical instrument for general use.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Manual surgical instrument for general use. 878.4800 Section 878.4800 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4800 Manual...

  1. 21 CFR 878.4800 - Manual surgical instrument for general use.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Manual surgical instrument for general use. 878.4800 Section 878.4800 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4800 Manual...

  2. 21 CFR 878.4800 - Manual surgical instrument for general use.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Manual surgical instrument for general use. 878.4800 Section 878.4800 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4800 Manual...

  3. 21 CFR 878.4800 - Manual surgical instrument for general use.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Manual surgical instrument for general use. 878.4800 Section 878.4800 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4800 Manual...

  4. Cost Savings of Standardization of Thoracic Surgical Instruments: The Process of Lean.

    PubMed

    Cichos, Kyle H; Linsky, Paul L; Wei, Benjamin; Minnich, Douglas J; Cerfolio, Robert J

    2017-12-01

    Our objective is to show the effect that standardization of surgical trays has on the number of instruments sterilized and on cost. We reviewed our most commonly used surgical trays with the 3 general thoracic surgeons in our division and agreed upon the least number of surgical instruments needed for mediastinoscopy, video-assisted thoracoscopic surgery, robotic thoracic surgery, and thoracotomy. We removed 59 of 79 instruments (75%) from the mediastinoscopy tray, 45 of 73 (62%) from the video-assisted thoracoscopic surgery tray, 51 of 84 (61%) from the robotic tray, and 50 of 113 (44%) from the thoracotomy tray. From January 2016 to December 2016, the estimated savings by procedure were video-assisted thoracoscopic surgery (n = 398) $21,890, robotic tray (n = 231) $19,400, thoracotomy (n = 163) $15,648, and mediastinoscopy (n = 162) $12,474. Estimated total savings were $69,412. The weight of the trays was reduced 70%, and the nonsteamed sterilization rate (opened trays that needed to be reprocessed) decreased from 2% to 0%. None of the surgeons requested any of the removed instruments. Standardization of thoracic surgical trays is possible despite having multiple thoracic surgeons. This process of lean (the removal of nonvalue steps or equipment) reduces the number of instruments cleaned and carried and reduces cost. It may also reduce the incidence of "wet loads" that require the resterilization of instruments. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  5. Application of type synthesis theory to the redesign of a complex surgical instrument.

    PubMed

    Lim, Jonas J B; Erdman, Arthur G

    2002-06-01

    Surgical instruments consist of basic mechanical components such as gears, links, pivots, sliders, etc., which are common in mechanical design. This paper describes the application of a method in the analysis and design of complex surgical instruments such as those employed in laparoscopic surgery. This is believed to be the first application of type synthesis theory to a complex medical instrument. Type synthesis is a methodology that can be applied during the conceptual phase of mechanical design. A handle assembly from a patented laparoscopic surgical stapler is used to illustrate the application of the design method developed. Type synthesis is applied on specific subsystems of the mechanism within the handle assembly where alternative design concepts are generated. Chosen concepts are then combined to form a new conceptual design for the handle assembly. The new handle assembly is improved because it has fewer number of parts, is a simpler design and is easier to assemble. Surgical instrument designers may use the methodology presented here to analyze the mechanical subsystems within complex instruments and to create new options that may offer improvements to the original design.

  6. Portable Chemical Sterilizer (PCS) for Surgical Instruments

    DTIC Science & Technology

    2004-12-01

    PORTABLE CHEMICAL STERILIZER (PCS) FOR SURGICAL INSTRUMENTS CJ Doona*, FE Feeherry, MA Curtin‡, K Kustin‡, S Kandlikar‡ U.S. Army-Soldier...denotes Contractors) Biomedical Technologies ABSTRACT A novel device called the Portable Chemical Sterilizer (PCS) has been developed for the...rapid, safe, portable, power-free, and convenient sterilization of objects or surfaces contaminated with pathogenic microorganisms that cause

  7. Use of a formal assessment instrument for evaluation of veterinary student surgical skills.

    PubMed

    Schnabel, Lauren V; Maza, Paul S; Williams, Kimberly M; Irby, Nita L; McDaniel, Carolyn M; Collins, Brian G

    2013-05-01

    To (1) evaluate the design and use of a global rating scale assessment instrument in veterinary medical education and; (2) examine the effectiveness of 2 surgical techniques courses for improving the surgical skills of veterinary students. Instrument development; observational; survey-based. Students (n = 16) registered for 2 elective surgical techniques courses were enrolled on a volunteer basis. A 5-point global rating scale instrument was designed for the evaluation of 12 basic surgical skills by faculty evaluators and used to obtain student start and end scores during the courses. Upon conclusion of the courses, students completed a survey from which their opinions on their improvement as well as their desire for feedback were obtained. All authors agreed the instrument was easy to use. As groups, 3rd year students, 4th year students, and all students combined had significantly higher total skill scores at the end of the courses compared to the start of the courses. Individually, 10 students (63%) had significant improvement in surgical skills as a result of their participation in the courses: 4 (100%) 3rd year and 6 (50%) 4th year students. Student survey responses revealed a strong desire for feedback as well as support of formal assessment methods. Only weak agreement was found between student opinions on their improvement and the authors' assessment scores. Assessment instruments are useful for (1) student evaluation and (2) for providing students with feedback on their surgical skills. © Copyright 2013 by The American College of Veterinary Surgeons.

  8. 21 CFR 886.4350 - Manual ophthalmic surgical instrument.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Manual ophthalmic surgical instrument. 886.4350 Section 886.4350 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... suturing needle, lachrymal probe, trabeculotomy probe, cornea-sclera punch, ophthalmic retractor...

  9. [Direct electric conduction glove for laparoscopic surgical instruments. Preliminary results of a prototype].

    PubMed

    Gentilli, Sergio; Morgandoa, Andrea; Velardocchia, Mauro; Pessione, Silvia; Pizzorno, Chiara

    2007-01-01

    The authors present their prototype of a system for electrical conduction in direct contact with laparoscopic tools, devised, designed and produced by them at the Politecnico di Torino Department of Mechanical Engineering. The system consists of a two-sided plate, one side being a non-conducting adhesive surface to stick to the surgical glove and the other a thin, flexible conductor shell. The authors used the instrument with surgical tools with metal handles during 4 laparoscopic procedures. Nowadays the method commonly used to electrify laparoscopic tools is by using a wire plugged to a fixed conducting point on the instrument. The prototype described here was devised and produced to avoid some of the awkwardness encountered during the numerous manoeuvres required to connect and disconnect the wire at the time of surgical intervention. This device permits the direct transfer (by contact) of electrical energy from the wire to surgical tools. The advantage is greater rapidity in changing surgical tools, with the possibility of immediately obtaining an electrified instrument in the surgeon's hand.

  10. Surgical treatment of pyogenic vertebral osteomyelitis with spinal instrumentation

    PubMed Central

    Chen, Wei-Hua; Jiang, Lei-Sheng

    2006-01-01

    Pyogenic vertebral osteomyelitis responds well to conservative treatment at early stage, but more complicated and advanced conditions, including mechanical spinal instability, epidural abscess formation, neurologic deficits, and refractoriness to antibiotic therapy, usually require surgical intervention. The subject of using metallic implants in the setting of infection remains controversial, although more and more surgeons acknowledge that instrumentation can help the body to combat the infection rather than to interfere with it. The combination of radical debridement and instrumentation has lots of merits such as, restoration and maintenance of the sagittal alignment of the spine, stabilization of the spinal column and reduction of bed rest period. This issue must be viewed in the context of the overall and detailed health conditions of the subjecting patient. We think the culprit for the recurrence of infection is not the implants itself, but is the compromised general health condition of the patients. In this review, we focus on surgical treatment of pyogenic vertebral osteomyelitis with special attention to the role of spinal instrumentation in the presence of pyogenic infection. PMID:17106664

  11. 3D printing of surgical instruments for long-duration space missions.

    PubMed

    Wong, Julielynn Y; Pfahnl, Andreas C

    2014-07-01

    The first off-Earth fused deposition modeling (FDM) 3D printer will explore thermoplastic manufacturing capabilities in microgravity. This study evaluated the feasibility of FDM 3D printing 10 acrylonitrile butadiene styrene (ABS) thermoplastic surgical instruments on Earth. Three-point bending tests compared stiffness and yield strength between FDM 3D printed and conventionally manufactured ABS thermoplastic. To evaluate the relative speed of using four printed instruments compared to conventional instruments, 13 surgeons completed simulated prepping, draping, incising, and suturing tasks. Each surgeon ranked the performance of six printed instruments using a 5-point Likert scale. At a thickness of 5.75 mm or more, the FDM printing process had a less than 10% detrimental effect on the tested yield strength and stiffness of horizontally printed ABS thermoplastic relative to conventional ABS thermoplastic. Significant weakness was observed when a bending load was applied transversely to a 3D printed layer. All timed tasks were successfully performed using a printed sponge stick, towel clamp, scalpel handle, and toothed forceps. There was no substantial difference in time to completion of simulated surgical tasks with control vs. 3D printed instruments. Of the surgeons, 100%, 92%, 85%, 77%, 77%, and 69% agreed that the printed smooth and tissue forceps, curved and straight hemostats, tissue and right angle clamps, respectively, would perform adequately. It is feasible to 3D print ABS thermoplastic surgical instruments on Earth. Loadbearing structures were designed to be thicker, when possible. Printing orientations were selected so that the printing layering direction of critical structures would not be transverse to bending loads.

  12. Research on seamless development of surgical instruments based on biological mechanisms using CAD and 3D printer.

    PubMed

    Yamamoto, Ikuo; Ota, Ren; Zhu, Rui; Lawn, Murray; Ishimatsu, Takakazu; Nagayasu, Takeshi; Yamasaki, Naoya; Takagi, Katsunori; Koji, Takehiko

    2015-01-01

    In the area of manufacturing surgical instruments, the ability to rapidly design, prototype and test surgical instruments is critical. This paper provides a simple case study of the rapid development of two bio-mechanism based surgical instruments which are ergonomic, aesthetic and were successfully designed, prototyped and conceptually tested in a very short period of time.

  13. The history of thoracic surgical instruments and instrumentation.

    PubMed

    Hagopian, E J; Mann, C; Galibert, L A; Steichen, F M

    2000-02-01

    Thoracic surgical practice has evolved from the innovations of its pioneers. Beginning with the stethoscope discovered by Laënnec with his system of auscultation, to the tools we use in the dissection and control of the hilum of the lung for resection, our practice of thoracic surgery has been entwined with the development of instruments and instrumentation. The development of strategies to prevent death from the open pneumothorax began with manual control of the mediastinum and progressed through differential pressure to, finally, the technique of intubation and the methods of positive-pressure and insufflation anesthesia. The instruments we place in our hands are not enough to define our art. Entry into the chest would not be possible without the use of rib retractors, rib shears, and even periosteal elevators. Finally, to the present day of minimally invasive techniques and the application of thoracoscopy for therapeutic purposes, we find the efforts of our predecessors well developed. For the progression from the fear of the open pneumothorax to the present-day state of the ease of thoracotomy for lung resection we are indebted to those who gave so much of their time and, for some, their lives to death from tuberculosis, to allow the advancement of our practice of surgery. These great people should be remembered not only for their acceptance of novel ideas but also, more importantly, for their lack of fear of testing them.

  14. Assessing the magnitude and costs of intraoperative inefficiencies attributable to surgical instrument trays.

    PubMed

    Stockert, Emily Walker; Langerman, Alexander

    2014-10-01

    Efficiency in the operating room has become a topic of great interest. This study aimed to quantify the percent use of instruments among common instrument trays across 4 busy surgical services: Otolaryngology, Plastic Surgery, Bariatric Surgery, and Neurosurgery. We further aimed to calculate the costs associated with tray and instrument sterilization, as well as the implications of missing or damaged instruments. This was a single-site, observational study conducted on the surgical instrumentation at a large academic medical center in Chicago. Data were collected through direct observation by a trained investigator. Operating room instrument use and labor time required for cleaning and repacking instrument trays in central sterile processing (CSP) were analyzed using descriptive statistics and linear regression. Institutional data on volume and expenses were gathered from hospital leadership. Forty-nine procedures and 237 individual trays were observed. Average instrument (±SD)use rates were 13.0% for Otolaryngology (±4.2%), 15.5% for Plastic Surgery (±2.9%), 18.2% for Bariatric Surgery (±5.0%), and 21.9% for Neurosurgery (±1.7%). An increasing number of instruments per tray was associated with decreased use and increased instrument error rate. Using recorded labor time, the cost of cleaning and repackaging an individual instrument was calculated to be $0.10. Adding in CSP operating expenses and instrument depreciation per use, total processing cost per instrument increases to $0.51 or more. Our study demonstrates that the percent use of instruments across surgical specialties and multiple tray types is low. Attention to tray composition may result in immediate and significant cost savings. Copyright © 2014 American College of Surgeons. Published by Elsevier Inc. All rights reserved.

  15. Gestonurse: a robotic surgical nurse for handling surgical instruments in the operating room.

    PubMed

    Jacob, Mithun; Li, Yu-Ting; Akingba, George; Wachs, Juan P

    2012-03-01

    While surgeon-scrub nurse collaboration provides a fast, straightforward and inexpensive method of delivering surgical instruments to the surgeon, it often results in "mistakes" (e.g. missing information, ambiguity of instructions and delays). It has been shown that these errors can have a negative impact on the outcome of the surgery. These errors could potentially be reduced or eliminated by introducing robotics into the operating room. Gesture control is a natural and fundamentally sound alternative that allows interaction without disturbing the normal flow of surgery. This paper describes the development of a robotic scrub nurse Gestonurse to support surgeons by passing surgical instruments during surgery as required. The robot responds to recognized hand signals detected through sophisticated computer vision and pattern recognition techniques. Experimental results show that 95% of the gestures were recognized correctly. The gesture recognition algorithm presented is robust to changes in scale and rotation of the hand gestures. The system was compared to human task performance and was found to be only 0.83 s slower on average.

  16. A cyber-physical management system for delivering and monitoring surgical instruments in the OR.

    PubMed

    Li, Yu-Ting; Jacob, Mithun; Akingba, George; Wachs, Juan P

    2013-08-01

    The standard practice in the operating room (OR) is having a surgical technician deliver surgical instruments to the surgeon quickly and inexpensively, as required. This human "in the loop" system may result in mistakes (eg, missing information, ambiguity of instructions, and delays). Errors can be reduced or eliminated by integrating information technology (IT) and cybernetics into the OR. Gesture and voice automatic acquisition, processing, and interpretation allow interaction with these new systems without disturbing the normal flow of surgery. This article describes the development of a cyber-physical management system (CPS), including a robotic scrub nurse, to support surgeons by passing surgical instruments during surgery as required and recording counts of surgical instruments into a personal health record (PHR). The robot used responds to hand signals and voice messages detected through sophisticated computer vision and data mining techniques. The CPS was tested during a mock surgery in the OR. The in situ experiment showed that the robot recognized hand gestures reliably (with an accuracy of 97%), it can retrieve instruments as close as 25 mm, and the total delivery time was less than 3 s on average. This online health tool allows the exchange of clinical and surgical information to electronic medical record-based and PHR-based applications among different hospitals, regardless of the style viewer. The CPS has the potential to be adopted in the OR to handle surgical instruments and track them in a safe and accurate manner, releasing the human scrub tech from these tasks.

  17. Stereoscopic Analysis of Silicone Breast Implant Shells Damaged by Surgical Instruments.

    PubMed

    Rapp, Derek A; Neaman, Keith C; Hammond, Dennis C

    2015-07-01

    Iatrogenic shell injury during the implantation and explantation of silicone gel breast implants may lead to eventual device failure. Identification of the patterns of injury caused by surgical instruments is important when attempting to characterize the cause of shell rupture. Understanding the true causes of device failure may help with its prevention. The purpose of this study was to microscopically characterize patterns of shell injury induced by various surgical instruments. Textured and smooth silicone gel implants were intentionally damaged with a variety of surgical instruments. Various scalpels and surgical scissors ranging in fineness were used to create full-thickness injuries in the implant shell. Optical microscopy and scanning electron microscopy were then used to image the injured area to determine patterns of injury. Full-thickness striations across the thickness of the shell could be seen with damage caused by scissors. The density of these striations correlated directly with the fineness of scissors used. No striations were seen with injuries caused by scalpels. Striations were only observed in injuries caused by scissors and suture needles. Striation density correlated with the coarseness of the cutting edge. No such striations were seen in shells damaged by a scalpel even when the angle of approach was changed. This difference can be of assistance in distinguishing between scissors versus scalpel injury of an implant shell.

  18. Automatic localization of the da Vinci surgical instrument tips in 3-D transrectal ultrasound.

    PubMed

    Mohareri, Omid; Ramezani, Mahdi; Adebar, Troy K; Abolmaesumi, Purang; Salcudean, Septimiu E

    2013-09-01

    Robot-assisted laparoscopic radical prostatectomy (RALRP) using the da Vinci surgical system is the current state-of-the-art treatment option for clinically confined prostate cancer. Given the limited field of view of the surgical site in RALRP, several groups have proposed the integration of transrectal ultrasound (TRUS) imaging in the surgical workflow to assist with accurate resection of the prostate and the sparing of the neurovascular bundles (NVBs). We previously introduced a robotic TRUS manipulator and a method for automatically tracking da Vinci surgical instruments with the TRUS imaging plane, in order to facilitate the integration of intraoperative TRUS in RALRP. Rapid and automatic registration of the kinematic frames of the da Vinci surgical system and the robotic TRUS probe manipulator is a critical component of the instrument tracking system. In this paper, we propose a fully automatic registration technique based on automatic 3-D TRUS localization of robot instrument tips pressed against the air-tissue boundary anterior to the prostate. The detection approach uses a multiscale filtering technique to identify and localize surgical instrument tips in the TRUS volume, and could also be used to detect other surface fiducials in 3-D ultrasound. Experiments have been performed using a tissue phantom and two ex vivo tissue samples to show the feasibility of the proposed methods. Also, an initial in vivo evaluation of the system has been carried out on a live anaesthetized dog with a da Vinci Si surgical system and a target registration error (defined as the root mean square distance of corresponding points after registration) of 2.68 mm has been achieved. Results show this method's accuracy and consistency for automatic registration of TRUS images to the da Vinci surgical system.

  19. Improving precise positioning of surgical robotic instruments by a three-side-view presentation system on telesurgery.

    PubMed

    Hori, Kenta; Kuroda, Tomohiro; Oyama, Hiroshi; Ozaki, Yasuhiko; Nakamura, Takehiko; Takahashi, Takashi

    2005-12-01

    For faultless collaboration among the surgeon, surgical staffs, and surgical robots in telesurgery, communication must include environmental information of the remote operating room, such as behavior of robots and staffs, vital information of a patient, named supporting information, in addition to view of surgical field. "Surgical Cockpit System, " which is a telesurgery support system that has been developed by the authors, is mainly focused on supporting information exchange between remote sites. Live video presentation is important technology for Surgical Cockpit System. Visualization method to give precise location/posture of surgical instruments is indispensable for accurate control and faultless operation. In this paper, the authors propose three-side-view presentation method for precise location/posture control of surgical instruments in telesurgery. The experimental results show that the proposed method improved accurate positioning of a telemanipulator.

  20. Reduction and standardization of surgical instruments in pediatric inguinal hernia repair.

    PubMed

    Koyle, Martin A; AlQarni, Naif; Odeh, Rakan; Butt, Hissan; Alkahtani, Mohammed M; Konstant, Louis; Pendergast, Lisa; Koyle, Leah C C; Baker, G Ross

    2018-02-01

    To standardize and reduce surgical instrumentation by >25% within a 9-month period for pediatric inguinal hernia repair (PIHR), using "improvement science" methodology. We prospectively evaluated instruments used for PIHR in 56 consecutive cases by individual surgeons across two separate subspecialties, pediatric surgery (S) and pediatric urology (U), to measure actual number of instruments used compared with existing practice based on preference cards. Based on this evaluation, a single preference card was developed using only instruments that had been used in >50% of all cases. A subsequent series of 52 cases was analyzed to assess whether the new tray contained the ideal instrumentation. Cycle time (CT), to sterilize and package the instruments, and weights of the trays were measured before and after the intervention. A survey of operating room (OR) nurses and U and S surgeons was conducted before and after the introduction of the standardized tray to assess the impact and perception of standardization. Prior to creating the standardized tray, a U PIHR tray contained 96 instruments with a weight of 13.5 lbs, while the S set contained 51, weighing 11.2 lbs. The final standardized set comprised 28 instruments and weighed 7.8 lbs. Of 52 PIHRs performed after standardization, in three (6%) instances additional instruments were requested. CT was reduced from 11 to 8 min (U and S respectively) to <5 min for the single tray. Nurses and surgeons reported that quality, safety, and efficiency were improved, and that efforts should continue to standardize instrumentation for other common surgeries. Standardization of surgical equipment can be employed across disciplines with the potential to reduce costs and positively impact quality, safety, and efficiencies. Copyright © 2017 Journal of Pediatric Urology Company. Published by Elsevier Ltd. All rights reserved.

  1. Instrument-mounted displays for reducing cognitive load during surgical navigation.

    PubMed

    Herrlich, Marc; Tavakol, Parnian; Black, David; Wenig, Dirk; Rieder, Christian; Malaka, Rainer; Kikinis, Ron

    2017-09-01

    Surgical navigation systems rely on a monitor placed in the operating room to relay information. Optimal monitor placement can be challenging in crowded rooms, and it is often not possible to place the monitor directly beside the situs. The operator must split attention between the navigation system and the situs. We present an approach for needle-based interventions to provide navigational feedback directly on the instrument and close to the situs by mounting a small display onto the needle. By mounting a small and lightweight smartwatch display directly onto the instrument, we are able to provide navigational guidance close to the situs and directly in the operator's field of view, thereby reducing the need to switch the focus of view between the situs and the navigation system. We devise a specific variant of the established crosshair metaphor suitable for the very limited screen space. We conduct an empirical user study comparing our approach to using a monitor and a combination of both. Results from the empirical user study show significant benefits for cognitive load, user preference, and general usability for the instrument-mounted display, while achieving the same level of performance in terms of time and accuracy compared to using a monitor. We successfully demonstrate the feasibility of our approach and potential benefits. With ongoing technological advancements, instrument-mounted displays might complement standard monitor setups for surgical navigation in order to lower cognitive demands and for improved usability of such systems.

  2. A Multicentre Audit of Single-Use Surgical Instruments (SUSI) for Tonsillectomy and Adenoidectomy

    PubMed Central

    O'Flynn, P; Silva, S; Kothari, P; Persaud, R

    2007-01-01

    INTRODUCTION Prions are resistant to conventional sterilisation procedures and, therefore, could be transmitted iatrogenically through re-usable adenoid and tonsil surgical instruments. Using disposable instruments would avoid the risk of transmission. We present the results of a complete audit loop using BBraun single-use surgical instruments (SUSI). PATIENTS AND METHODS This was a prospective multicentre audit. Surgeons were asked to fill in a standardised questionnaire recording details including postoperative complications, and evaluation of each piece of equipment compared with their own experience of conventional re-usable instruments. In the first cycle, constructive criticisms of the instruments were noted and the manufacturers modified the instruments accordingly. A second cycle of audit was subsequently undertaken. RESULTS A total of 86 patients were audited in the first cycle and 97 in the second cycle. Postoperative haemorrhage rate for both cycles was well within acceptable range. In the first audit cycle, surgeons generally found the Draffin rods, Boyle-Davis gag and bipolar diathermy forceps of poor quality and difficult to use. These were redesigned and, on repeat evaluation during the second audit cycle, were found to be just as good, if not better, than the re-usable instruments. CONCLUSIONS This study suggests that SUSI may be just as good as re-usable instruments. Furthermore, they may be more cost effective. PMID:18201478

  3. Statistical Segmentation of Surgical Instruments in 3D Ultrasound Images

    PubMed Central

    Linguraru, Marius George; Vasilyev, Nikolay V.; Del Nido, Pedro J.; Howe, Robert D.

    2008-01-01

    The recent development of real-time 3D ultrasound enables intracardiac beating heart procedures, but the distorted appearance of surgical instruments is a major challenge to surgeons. In addition, tissue and instruments have similar gray levels in US images and the interface between instruments and tissue is poorly defined. We present an algorithm that automatically estimates instrument location in intracardiac procedures. Expert-segmented images are used to initialize the statistical distributions of blood, tissue and instruments. Voxels are labeled through an iterative expectation-maximization algorithm using information from the neighboring voxels through a smoothing kernel. Once the three classes of voxels are separated, additional neighboring information is combined with the known shape characteristics of instruments in order to correct for misclassifications. We analyze the major axis of segmented data through their principal components and refine the results by a watershed transform, which corrects the results at the contact between instrument and tissue. We present results on 3D in-vitro data from a tank trial, and 3D in-vivo data from cardiac interventions on porcine beating hearts, using instruments of four types of materials. The comparison of algorithm results to expert-annotated images shows the correct segmentation and position of the instrument shaft. PMID:17521802

  4. Development and validation of an objective instrument to measure surgical performance at tonsillectomy.

    PubMed

    Roberson, David W; Kentala, Erna; Forbes, Peter

    2005-12-01

    The goals of this project were 1) to develop and validate an objective instrument to measure surgical performance at tonsillectomy, 2) to assess its interobserver and interobservation reliability and construct validity, and 3) to select those items with best reliability and most independent information to design a simplified form suitable for routine use in otolaryngology surgical evaluation. Prospective, observational data collection for an educational quality improvement project. The evaluation instrument was based on previous instruments developed in general surgery with input from attending otolaryngologic surgeons and experts in medical education. It was pilot tested and subjected to iterative improvements. After the instrument was finalized, a total of 55 tonsillectomies were observed and scored during academic year 2002 to 2003: 45 cases by residents at different points during their rotation, 5 by fellows, and 5 by faculty. Results were assessed for interobserver reliability, interobservation reliability, and construct validity. Factor analysis was used to identify items with independent information. Interobserver and interobservation reliability was high. On technical items, faculty substantially outperformed fellows, who in turn outperformed residents (P < .0001 for both comparisons). On the "global" scale (overall assessment), residents improved an average of 1 full point (on a 5 point scale) during a 3 month rotation (P = .01). In the subscale of "patient care," results were less clear cut: fellows outperformed residents, who in turn outperformed faculty, but only the fellows to faculty comparison was statistically significant (P = .04), and residents did not clearly improve over time (P = .36). Factor analysis demonstrated that technical items and patient care items factor separately and thus represent separate skill domains in surgery. It is possible to objectively measure surgical skill at tonsillectomy with high reliability and good construct

  5. From flint to stainless steel: observations on surgical instrument composition.

    PubMed Central

    Kirkup, J.

    1993-01-01

    Man's failure to extract deeply embedded thorns and arrowheads, with bare hands and teeth, stimulated 'instrument substitutes' mimicking these appendages. Evidence from primitive communities suggest animal, plant and mineral items were employed, both before and after metal became the standard material of today's armamentarium. Changing surgical instrument composition has mirrored concurrent technology and manufacturing methods both of which are reviewed. Particular significance is accorded flint, bronze, crucible steel, thermal sterilisation, nickel-plate, stainless steel and disposable plastics. The paper is based on an exhibition From Flint to Stainless Steel on display at the College. Images Figure 1 Figure 2 Figure 3 Figure 4 Figure 5 PMID:8215156

  6. Amyloid-specific fluorophores for the rapid, sensitive in situ detection of prion contamination on surgical instruments.

    PubMed

    Lipscomb, I P; Hervé, R; Harris, K; Pinchin, H; Collin, R; Keevil, C W

    2007-09-01

    Prion diseases or transmissible spongiform encephalopathies (TSEs) are a group of rare, transmissible and fatal neurodegenerative diseases associated with the protein agent (PrP(Sc)). As such, the sensitive and rapid detection of prion PrP(Sc) amyloid on the surface of suspect surgical instruments is of great importance and may even allow remedial action to be taken prior to any further operative intervention and possible iatrogenic transmission. However, conventional PrP(Sc) detection methodologies tend to rely on the inefficient and unreliable removal of suspect material from a surface using swabs or wipes prior to antibody analysis. Here we show how the combination of an advanced light microscope technique, episcopic differential interference contrast/epifluorescence (EDIC/EF) microscopy, and the application of beta-amyloid fluorescent thiazole markers (thioflavin T, thioflavin S) can be used to detect, in situ, submicron (attomole) levels of prion protein amyloid contamination in brain and spleen sections, smears and homogenate on surgical stainless steel surfaces and surgical instruments. This technique, although not specific to an amyloid type, can be used to verify that surgical instruments are substantially free from prion amyloid protein soiling and hence reduce the risk of iatrogenic transmission.

  7. Material selection indices for design of surgical instruments with long tubular shafts.

    PubMed

    Nelson, Carl A

    2013-02-01

    In any medical device design process, material selection plays an important role. For devices which sustain mechanical loading, strength and stiffness requirements can be significant drivers of the design. This paper examines the specific case of minimally invasive surgical instruments, including robotic instruments, having long, tubular shafts. Material properties-based selection indices are derived for achieving high performance of these devices in terms of strength and stiffness, and the use of these indices for informing the medical device design problem is illustrated.

  8. Valve in valve transcatheter aortic valve implantation (ViV-TAVI) versus redo-Surgical aortic valve replacement (redo-SAVR): A systematic review and meta-analysis.

    PubMed

    Nalluri, Nikhil; Atti, Varunsiri; Munir, Abdullah B; Karam, Boutros; Patel, Nileshkumar J; Kumar, Varun; Vemula, Praveen; Edla, Sushruth; Asti, Deepak; Paturu, Amrutha; Gayam, Sriramya; Spagnola, Jonathan; Barsoum, Emad; Maniatis, Gregory A; Tamburrino, Frank; Kandov, Ruben; Lafferty, James; Kliger, Chad

    2018-05-20

    Bioprosthetic (BP) valves have been increasingly used for aortic valve replacement over the last decade. Due to their limited durability, patients presenting with failed BP valves are rising. Valve in Valve - Transcatheter Aortic Valve Implantation (ViV-TAVI) emerged as an alternative to the gold standard redo-Surgical Aortic Valve Replacement (redo-SAVR). However, the utility of ViV-TAVI is poorly understood. A systematic electronic search of the scientific literature was done in PubMed, EMBASE, SCOPUS, Google Scholar, and ClinicalTrials.gov. Only studies which compared the safety and efficacy of ViV-TAVI and redo-SAVR head to head in failed BP valves were included. Six observational studies were eligible and included 594 patients, of whom 255 underwent ViV- TAVI and 339 underwent redo-SAVR. There was no significant difference between ViV-TAVI and redo- SAVR for procedural, 30 day and 1 year mortality rates. ViV-TAVI was associated with lower risk of permanent pacemaker implantation (PPI) (OR: 0.43, CI: 0.21-0.89; P = 0.02) and a trend toward increased risk of paravalvular leak (PVL) (OR: 5.45, CI: 0.94-31.58; P = 0.06). There was no significant difference for stroke, major bleeding, vascular complications and postprocedural aortic valvular gradients more than 20 mm-hg. Our results reiterate the safety and feasibility of ViV-TAVI for failed aortic BP valves in patients deemed to be at high risk for surgery. VIV-TAVI was associated with lower risk of permanent pacemaker implantation with a trend toward increased risk of paravalvular leak. © 2018, Wiley Periodicals, Inc.

  9. Surgical infection in a videolaparoscopic cholecystectomy when using peracetic acid for the sterilization of instruments.

    PubMed

    de Melo, Edluza Maria Viana Bezerra; Leão, Cristiano de Souza; Andreto, Luciana Marques; de Mello, Maria Júlia Gonçalves

    2013-01-01

    To determine the frequency of surgical site infection in patients undergoing laparoscopic cholecystectomy with instruments sterilized by peracetic acid. We conducted a retrospective, cohort, descriptive, cross-sectional study. Peracetic acid has been used for sterilization following the protocol recommended by the manufacturer. We observed the criteria and indicators of process and structure for preventing surgical site infection pre and intraoperatively. For epidemiological surveillance, outpatient visits were scheduled for the 15th and between the 30th and 45th days after discharge. Among the 247 patients, there were two cases of surgical site infection (0.8%). One patient was readmitted to systemic antibiotic therapy and percutaneous puncture; in the other the infection was superficial and followed at the clinic. Ethical issues prevent the conduction of a prospective study because of peracetic acid have been banned for the sterilization of instruments that penetrate organs and cavities. Nevertheless, these results encourage prospective case-control studies comparing its use (historical control) with ethylene oxide sterilization.

  10. A Novel Method to Decontaminate Surgical Instruments for Operational and Austere Environments.

    PubMed

    Knox, Randy W; Demons, Samandra T; Cunningham, Cord W

    2015-12-01

    The purpose of this investigation was to test a field-expedient, cost-effective method to decontaminate, sterilize, and package surgical instruments in an operational (combat) or austere environment using chlorhexidine sponges, ultraviolet C (UVC) light, and commercially available vacuum sealing. This was a bench study of 4 experimental groups and 1 control group of 120 surgical instruments. Experimental groups were inoculated with a 10(6) concentration of common wound bacteria. The control group was vacuum sealed without inoculum. Groups 1, 2, and 3 were first scrubbed with a chlorhexidine sponge, rinsed, and dried. Group 1 was then packaged; group 2 was irradiated with UVC light, then packaged; group 3 was packaged, then irradiated with UVC light through the bag; and group 4 was packaged without chlorhexidine scrubbing or UVC irradiation. The UVC was not tested by itself, as it does not grossly clean. The instruments were stored overnight and tested for remaining colony forming units (CFU). Data analysis was conducted using analysis of variance and group comparisons using the Tukey method. Group 4 CFU was statistically greater (P < .001) than the control group and groups 1 through 3. There was no statistically significant difference between the control group and groups 1 through 3. Vacuum sealing of chlorhexidine-scrubbed contaminated instruments with and without handheld UVC irradiation appears to be an acceptable method of field decontamination. Chlorhexidine scrubbing alone achieved a 99.9% reduction in CFU, whereas adding UVC before packaging achieved sterilization or 100% reduction in CFU, and UVC through the bag achieved disinfection. Published by Elsevier Inc.

  11. Code Grey: Stained Surgical Instruments and Their Impact on One Canadian Health Authority.

    PubMed

    Kean, Rob; Johnson, Ron; Doyle, Michael

    2017-01-01

    In 2016, NL's largest RHA was faced with serious challenges stemming from the discovery of stained surgical instruments at its two largest hospitals. This discovery prompted a series of postponed surgeries, an extensive internal mobilization of labour and the purchase of millions of dollars of new equipment. In tackling these challenges, the organization not only acquired a better understanding of its surgical tools, but it also gained renewed appreciation for the resilience of its human resources. By describing this incident and the lessons learned, we hope to offer insight to providers in similar circumstances.

  12. Integrative advances for OCT-guided ophthalmic surgery and intraoperative OCT: microscope integration, surgical instrumentation, and heads-up display surgeon feedback.

    PubMed

    Ehlers, Justis P; Srivastava, Sunil K; Feiler, Daniel; Noonan, Amanda I; Rollins, Andrew M; Tao, Yuankai K

    2014-01-01

    To demonstrate key integrative advances in microscope-integrated intraoperative optical coherence tomography (iOCT) technology that will facilitate adoption and utilization during ophthalmic surgery. We developed a second-generation prototype microscope-integrated iOCT system that interfaces directly with a standard ophthalmic surgical microscope. Novel features for improved design and functionality included improved profile and ergonomics, as well as a tunable lens system for optimized image quality and heads-up display (HUD) system for surgeon feedback. Novel material testing was performed for potential suitability for OCT-compatible instrumentation based on light scattering and transmission characteristics. Prototype surgical instruments were developed based on material testing and tested using the microscope-integrated iOCT system. Several surgical maneuvers were performed and imaged, and surgical motion visualization was evaluated with a unique scanning and image processing protocol. High-resolution images were successfully obtained with the microscope-integrated iOCT system with HUD feedback. Six semi-transparent materials were characterized to determine their attenuation coefficients and scatter density with an 830 nm OCT light source. Based on these optical properties, polycarbonate was selected as a material substrate for prototype instrument construction. A surgical pick, retinal forceps, and corneal needle were constructed with semi-transparent materials. Excellent visualization of both the underlying tissues and surgical instrument were achieved on OCT cross-section. Using model eyes, various surgical maneuvers were visualized, including membrane peeling, vessel manipulation, cannulation of the subretinal space, subretinal intraocular foreign body removal, and corneal penetration. Significant iterative improvements in integrative technology related to iOCT and ophthalmic surgery are demonstrated.

  13. Method, accuracy and limitation of computer interaction in the operating room by a navigated surgical instrument.

    PubMed

    Hurka, Florian; Wenger, Thomas; Heininger, Sebastian; Lueth, Tim C

    2011-01-01

    This article describes a new interaction device for surgical navigation systems--the so-called navigation mouse system. The idea is to use a tracked instrument of a surgical navigation system like a pointer to control the software. The new interaction system extends existing navigation systems with a microcontroller-unit. The microcontroller-unit uses the existing communication line to extract the needed 3D-information of an instrument to calculate positions analogous to the PC mouse cursor and click events. These positions and events are used to manipulate the navigation system. In an experimental setup the reachable accuracy with the new mouse system is shown.

  14. 21 CFR 878.4810 - Laser surgical instrument for use in general and plastic surgery and in dermatology.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... plastic surgery and in dermatology. 878.4810 Section 878.4810 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4810 Laser surgical instrument for use in general and plastic surgery and in...

  15. 21 CFR 878.4810 - Laser surgical instrument for use in general and plastic surgery and in dermatology.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... plastic surgery and in dermatology. 878.4810 Section 878.4810 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4810 Laser surgical instrument for use in general and plastic surgery and in...

  16. 21 CFR 878.4810 - Laser surgical instrument for use in general and plastic surgery and in dermatology.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... plastic surgery and in dermatology. 878.4810 Section 878.4810 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4810 Laser surgical instrument for use in general and plastic surgery and in...

  17. 21 CFR 878.4810 - Laser surgical instrument for use in general and plastic surgery and in dermatology.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... plastic surgery and in dermatology. 878.4810 Section 878.4810 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4810 Laser surgical instrument for use in general and plastic surgery and in...

  18. 21 CFR 878.4810 - Laser surgical instrument for use in general and plastic surgery and in dermatology.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... plastic surgery and in dermatology. 878.4810 Section 878.4810 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4810 Laser surgical instrument for use in general and plastic surgery and in...

  19. A novel 4-DOF surgical instrument with modular joints and 6-Axis Force sensing capability.

    PubMed

    Li, Kun; Pan, Bo; Zhang, Fuhai; Gao, Wenpeng; Fu, Yili; Wang, Shuguo

    2017-03-01

    It is difficult for surgeons to exert appropriate forces during delicate operations due to lack of force feedback in robot-assisted minimally invasive surgery (RMIS). A 4-DOF surgical grasper with a modular wrist and 6-axis force sensing capability is developed. A grasper integrated with a miniature force and torque sensor based on the Stewart platform is designed, and a cable tension decomposition mechanism is designed to alleviate influence of the cable tension to the sensor. A modularized wrist consisting of four joint units is designed to facilitate integration of the sensor and eliminate coupled motion of the wrist. Sensing ranges of this instrument are ±10 N and ±160 N mm, and resolutions are 1.2% in radial directions, 5% in axial direction, and 4.2% in rotational directions. An ex vivo experiment shows that this instrument prototype successfully measures the interaction forces. A 4-DOF surgical instrument with modular joints and 6-axis force sensing capability is developed. This instrument can be used for force feedback in RMIS. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  20. Integrative Advances for OCT-Guided Ophthalmic Surgery and Intraoperative OCT: Microscope Integration, Surgical Instrumentation, and Heads-Up Display Surgeon Feedback

    PubMed Central

    Ehlers, Justis P.; Srivastava, Sunil K.; Feiler, Daniel; Noonan, Amanda I.; Rollins, Andrew M.; Tao, Yuankai K.

    2014-01-01

    Purpose To demonstrate key integrative advances in microscope-integrated intraoperative optical coherence tomography (iOCT) technology that will facilitate adoption and utilization during ophthalmic surgery. Methods We developed a second-generation prototype microscope-integrated iOCT system that interfaces directly with a standard ophthalmic surgical microscope. Novel features for improved design and functionality included improved profile and ergonomics, as well as a tunable lens system for optimized image quality and heads-up display (HUD) system for surgeon feedback. Novel material testing was performed for potential suitability for OCT-compatible instrumentation based on light scattering and transmission characteristics. Prototype surgical instruments were developed based on material testing and tested using the microscope-integrated iOCT system. Several surgical maneuvers were performed and imaged, and surgical motion visualization was evaluated with a unique scanning and image processing protocol. Results High-resolution images were successfully obtained with the microscope-integrated iOCT system with HUD feedback. Six semi-transparent materials were characterized to determine their attenuation coefficients and scatter density with an 830 nm OCT light source. Based on these optical properties, polycarbonate was selected as a material substrate for prototype instrument construction. A surgical pick, retinal forceps, and corneal needle were constructed with semi-transparent materials. Excellent visualization of both the underlying tissues and surgical instrument were achieved on OCT cross-section. Using model eyes, various surgical maneuvers were visualized, including membrane peeling, vessel manipulation, cannulation of the subretinal space, subretinal intraocular foreign body removal, and corneal penetration. Conclusions Significant iterative improvements in integrative technology related to iOCT and ophthalmic surgery are demonstrated. PMID:25141340

  1. Passive Markers for Tracking Surgical Instruments in Real-Time 3-D Ultrasound Imaging

    PubMed Central

    Stoll, Jeffrey; Ren, Hongliang; Dupont, Pierre E.

    2013-01-01

    A family of passive echogenic markers is presented by which the position and orientation of a surgical instrument can be determined in a 3-D ultrasound volume, using simple image processing. Markers are attached near the distal end of the instrument so that they appear in the ultrasound volume along with the instrument tip. They are detected and measured within the ultrasound image, thus requiring no external tracking device. This approach facilitates imaging instruments and tissue simultaneously in ultrasound-guided interventions. Marker-based estimates of instrument pose can be used in augmented reality displays or for image-based servoing. Design principles for marker shapes are presented that ensure imaging system and measurement uniqueness constraints are met. An error analysis is included that can be used to guide marker design and which also establishes a lower bound on measurement uncertainty. Finally, examples of marker measurement and tracking algorithms are presented along with experimental validation of the concepts. PMID:22042148

  2. [Surgical Roman instruments in the Museum of History of Medicine of the University of Rome "La Sapienza"].

    PubMed

    Gazzaniga, V; Serarcangeli, C

    1999-01-01

    The Museum of History of Medicine at the University of Rome "La Sapienza" keeps numerous roman surgical instruments, dating from the 1st century A.D. This article offers a short review of the critical literature existing on the topic, together with a temporary catalogue of the instruments.

  3. Hernia Surgical Mesh Implants

    MedlinePlus

    ... Surgical Clinics of North America; 83(5):1045-51, v-vi. 2 . http://www.facs.org/public_ ... FDA Contact FDA Browse by Product Area Product Areas back Food Drugs Medical Devices Radiation-Emitting Products ...

  4. Analysis of surgical smoke produced by various energy-based instruments and effect on laparoscopic visibility.

    PubMed

    Weld, Kyle J; Dryer, Stephen; Ames, Caroline D; Cho, Kuk; Hogan, Chris; Lee, Myonghwa; Biswas, Pratim; Landman, Jaime

    2007-03-01

    We analyzed the smoke plume produced by various energy-based laparoscopic instruments and determined its effect on laparoscopic visibility. The Bipolar Macroforceps, Harmonic Scalpel, Floating Ball, and Monopolar Shears were applied in vitro to porcine psoas muscle. An Aerodynamic Particle Sizer and Electrostatic Classifier provided a size distribution of the plume for particles >500 nm and <500 nm, and a geometric mean particle size was calculated. A Condensation Particle Counter provided the total particle-number concentration. Electron microscopy was used to characterize particle size and shape further. Visibility was calculated using the measured-size distribution data and the Rayleigh and Mie light-scattering theories. The real-time instruments were successful in measuring aerosolized particle size distributions in two size ranges. Electron microscopy revealed smaller, homogeneous, spherical particles and larger, irregular particles consistent with cellular components. The aerosol produced by the Bipolar Macroforceps obscured visibility the least (relative visibility 0.887) among the instruments tested. Particles from the Harmonic Scalpel resulted in a relative visibility of 0.801. Monopolar-based instruments produced plumes responsible for the poorest relative visibility (Floating Ball 0.252; Monopolar Shears 0.026). Surgical smoke is composed of two distinct particle populations caused by the nucleation of vapors as they cool (the small particles) and the entrainment of tissue secondary to mechanical aspects (the large particles). High concentrations of small particles are most responsible for the deterioration in laparoscopic vision. Bipolar and ultrasonic instruments generate a surgical plume that causes the least deterioration of visibility among the instruments tested.

  5. 40 CFR Appendix Vi to Part 261 - Reserved

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... AND LISTING OF HAZARDOUS WASTE Financial Requirements for Management of Excluded Hazardous Secondary Materials Wording of the instruments. Appendix VI to Part 261 [Reserved for Etiologic Agents] ...

  6. Surgical robotics beyond enhanced dexterity instrumentation: a survey of machine learning techniques and their role in intelligent and autonomous surgical actions.

    PubMed

    Kassahun, Yohannes; Yu, Bingbin; Tibebu, Abraham Temesgen; Stoyanov, Danail; Giannarou, Stamatia; Metzen, Jan Hendrik; Vander Poorten, Emmanuel

    2016-04-01

    Advances in technology and computing play an increasingly important role in the evolution of modern surgical techniques and paradigms. This article reviews the current role of machine learning (ML) techniques in the context of surgery with a focus on surgical robotics (SR). Also, we provide a perspective on the future possibilities for enhancing the effectiveness of procedures by integrating ML in the operating room. The review is focused on ML techniques directly applied to surgery, surgical robotics, surgical training and assessment. The widespread use of ML methods in diagnosis and medical image computing is beyond the scope of the review. Searches were performed on PubMed and IEEE Explore using combinations of keywords: ML, surgery, robotics, surgical and medical robotics, skill learning, skill analysis and learning to perceive. Studies making use of ML methods in the context of surgery are increasingly being reported. In particular, there is an increasing interest in using ML for developing tools to understand and model surgical skill and competence or to extract surgical workflow. Many researchers begin to integrate this understanding into the control of recent surgical robots and devices. ML is an expanding field. It is popular as it allows efficient processing of vast amounts of data for interpreting and real-time decision making. Already widely used in imaging and diagnosis, it is believed that ML will also play an important role in surgery and interventional treatments. In particular, ML could become a game changer into the conception of cognitive surgical robots. Such robots endowed with cognitive skills would assist the surgical team also on a cognitive level, such as possibly lowering the mental load of the team. For example, ML could help extracting surgical skill, learned through demonstration by human experts, and could transfer this to robotic skills. Such intelligent surgical assistance would significantly surpass the state of the art in surgical

  7. Analysis of risk factors for loss of lumbar lordosis in patients who had surgical treatment with segmental instrumentation for adolescent idiopathic scoliosis.

    PubMed

    Trobisch, Per D; Samdani, Amer F; Betz, Randal R; Bastrom, Tracey; Pahys, Joshua M; Cahill, Patrick J

    2013-06-01

    Iatrogenic flattening of lumbar lordosis in patients with adolescent idiopathic scoliosis (AIS) was a major downside of first generation instrumentation. Current instrumentation systems allow a three-dimensional scoliosis correction, but flattening of lumbar lordosis remains a significant problem which is associated with decreased health-related quality of life. This study sought to identify risk factors for loss of lumbar lordosis in patients who had surgical correction of AIS with the use of segmental instrumentation. Patients were included if they had surgical correction for AIS with segmental pedicle screw instrumentation Lenke type 1 or 2 and if they had a minimum follow-up of 24 months. Two groups were created, based on the average loss of lumbar lordosis. The two groups were then compared and multivariate analysis was performed to identify parameters that correlated to loss of lumbar lordosis. Four hundred and seventeen patients were analyzed for this study. The average loss of lumbar lordosis at 24 months follow-up was an increase of 10° lordosis for group 1 and a decrease of 15° for group 2. Risk factors for loss of lumbar lordosis included a high preoperative lumbar lordosis, surgical decrease of thoracic kyphosis, and the particular operating surgeon. The lowest instrumented vertebra or spinopelvic parameters were two of many parameters that did not seem to influence loss of lumbar lordosis. This study identified important risk factors for decrease of lumbar lordosis in patients who had surgical treatment for AIS with segmental pedicle screw instrumentation, including a high preoperative lumbar lordosis, surgical decrease of thoracic kyphosis, and factors attributable to a particular operating surgeon that were not quantified in this study.

  8. Patient-Reported Outcome Instruments for Surgical and Traumatic Scars: A Systematic Review of their Development, Content, and Psychometric Validation.

    PubMed

    Mundy, Lily R; Miller, H Catherine; Klassen, Anne F; Cano, Stefan J; Pusic, Andrea L

    2016-10-01

    Patient-reported outcomes (PROs) are of growing importance in research and clinical care and may be used as primary outcomes or as compliments to traditional surgical outcomes. In assessing the impact of surgical and traumatic scars, PROs are often the most meaningful. To assess outcomes from the patient perspective, rigorously developed and validated PRO instruments are essential. The authors conducted a systematic literature review to identify PRO instruments developed and/or validated for patients with surgical and/or non-burn traumatic scars. Identified instruments were assessed for content, development process, and validation under recommended guidelines for PRO instrument development. The systematic review identified 6534 articles. After review, we identified four PRO instruments meeting inclusion criteria: patient and observer scar assessment scale (POSAS), bock quality of life questionnaire for patients with keloid and hypertrophic scarring (Bock), patient scar assessment questionnaire (PSAQ), and patient-reported impact of scars measure (PRISM). Common concepts measured were symptoms and psychosocial well-being. Only PSAQ had a dedicated appearance domain. Qualitative data were used to inform content for the PSAQ and PRISM, and a modern psychometric approach (Rasch Measurement Theory) was used to develop PRISM and to test POSAS. Overall, PRISM demonstrated the most rigorous design and validation process, however, was limited by the lack of a dedicated appearance domain. PRO instruments to evaluate outcomes in scars exist but vary in terms of concepts measured and psychometric soundness. This review discusses the strengths and weaknesses of existing instruments, highlighting the need for future scar-focused PRO instrument development. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to Table of Contents or the online Instructions to Authors www

  9. Surgical instrument biocontaminant fluorescence detection in ambient lighting conditions for hospital reprocessing and sterilization department (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Baribeau, François; Bubel, Annie; Dumont, Guillaume; Vachon, Carl; Lépine, André; Rochefort, Stéphane; Massicotte, Martin; Buteau-Vaillancourt, Louis; Gallant, Pascal; Mermut, Ozzy

    2017-03-01

    Hospitals currently rely on simple human visual inspection for assessing cleanliness of surgical instruments. Studies showed that surgical site infections are in part attributed to inadequate cleaning of medical devices. Standards groups recognize the need to objectively quantify the amount of residues on surgical instruments and establish guidelines. We developed a portable technology for the detection of contaminants on surgical instruments through fluorescence following cleaning. Weak fluorescence signals are usually detected in the obscurity only with the lighting of the excitation source. The key element of this system is that it works in ambient lighting conditions, a requirement to not disturb the normal workflow of hospital reprocessing facilities. A biocompatible fluorescent dye is added to the detergent and labels the proteins of organic residues. It is resistant to the harsh environment in a washer-disinfector. Two inspection devices have been developed with a 488nm laser as the excitation source: a handheld scanner and a tabletop station using spectral-domain and time-domain ambient light cancellation schemes. The systems are eye safe and equipped with image processing and interfacing software to provide visual or audible warnings to the operator based on a set of adjustable signal thresholds. Micron-scale residues are detected by the system which can also evaluate soil size and mass. Unlike swabbing, it can inspect whole tools in real-time. The technology has been validated in an independent hospital decontamination research laboratory. It also has potential applications in the forensics, agro-food, and space fields. Technical aspects and results will be presented and discussed.

  10. Evidence-based care bundles for preventing surgical site infections in spinal instrumentation surgery.

    PubMed

    Yamada, Koji; Abe, Hiroaki; Higashikawa, Akiro; Tonosu, Juichi; Kuniya, Takashi; Nakajima, Koji; Fujii, Haruko; Niwa, Kazuki; Shinozaki, Tomohiro; Watanabe, Kenichi; Sakae, Tanaka; Okazaki, Hiroshi

    2018-05-22

    Retrospective study, using prospectively collected data. To evaluate the impact of evidence-based care bundles for preventing surgical site infections (SSI) in spinal instrumentation surgery. About half of all SSIs are preventable via evidence-based methods. For successful SSI prevention, the bacterial load must be minimized, and methicillin-resistant Staphylococcus aureus (MRSA) protection must be maximized. However, it is difficult to cover all of these requirements by single preventative method. We screened consecutive patients scheduled for spinal instrumentation surgeries at a single tertiary referral hospital for high surgical, SSI, and MRSA colonization risks. Evidence-based care bundles were implemented for high risk patients and included: 1) additional vancomycin prophylaxis, 2) diluted povidone-iodine irrigation, and 3) nasal and body decontamination. Patient demographics, comorbidities, operative features, and SSIs reported to the Japanese Nosocomial Infections Surveillance system were prospectively obtained in the same method by the same assessor and were used for the analyses. The results were compared before and after the application of the bundle. There were 1,042 spinal instrumentation surgeries (741 before and 301 after care bundles) performed from November 2010 to December 2015. Of 301 surgeries, 57 cases (18.9%) received care bundles. There were no significant differences in patient backgrounds before and after the intervention. The SSI rate decreased significantly from 3.8% to 0.7% (P < 0.01) after the intervention, with an overall 82% relative risk reduction. A significant protective effect was observed in the multivariate analysis (adjusted odds ratio 0.18, 95% confidence interval: 0.04-0.77, P = 0.02). There were no MRSA-related SSIs among those that received care bundles, even though MRSA was the predominant pathogen in the study population. Evidence-based care bundles, applied in selected high-risk spinal instrumentation cases

  11. Design of a surgical instrument for removing bone to provide screw access to a spinal fusion cage.

    PubMed

    Jabbary Aslani, F; Hukins, D W L; Shepherd, D E T; Parry, J J; Fennell, A J; Lambell, S

    2012-01-01

    A surgical instrument to aid implantation of a range of lumbar spinal fusion cages has been developed. Once the cage is in position, the entrance to screw holes is partially blocked by the edge of the vertebral body. In order to insert fixation screws to secure the cage between the vertebrae, some part of the blocking edge has to be removed. Rongeurs are currently being used, but they can be time consuming and have the disadvantage that they may remove more bone than is necessary and may cause damage to the fusion cage if not used with care. In addition, access around some of the screw holes may be difficult. The aim of this instrument was to overcome these shortcomings. This paper describes the design of a surgical instrument for cutting edges from vertebral bodies. The development and evaluation of concept designs are presented and discussed. Potential risks were considered and modifications were performed on the selected concept. Functional prototypes were manufactured and tested on sheep lumbar vertebrae. The results showed that the newly designed cutting instrument functions as required and removes the required amount of bone from the vertebral body edge.

  12. Tracking-by-detection of surgical instruments in minimally invasive surgery via the convolutional neural network deep learning-based method.

    PubMed

    Zhao, Zijian; Voros, Sandrine; Weng, Ying; Chang, Faliang; Li, Ruijian

    2017-12-01

    Worldwide propagation of minimally invasive surgeries (MIS) is hindered by their drawback of indirect observation and manipulation, while monitoring of surgical instruments moving in the operated body required by surgeons is a challenging problem. Tracking of surgical instruments by vision-based methods is quite lucrative, due to its flexible implementation via software-based control with no need to modify instruments or surgical workflow. A MIS instrument is conventionally split into a shaft and end-effector portions, while a 2D/3D tracking-by-detection framework is proposed, which performs the shaft tracking followed by the end-effector one. The former portion is described by line features via the RANSAC scheme, while the latter is depicted by special image features based on deep learning through a well-trained convolutional neural network. The method verification in 2D and 3D formulation is performed through the experiments on ex-vivo video sequences, while qualitative validation on in-vivo video sequences is obtained. The proposed method provides robust and accurate tracking, which is confirmed by the experimental results: its 3D performance in ex-vivo video sequences exceeds those of the available state-of -the-art methods. Moreover, the experiments on in-vivo sequences demonstrate that the proposed method can tackle the difficult condition of tracking with unknown camera parameters. Further refinements of the method will refer to the occlusion and multi-instrumental MIS applications.

  13. A multinational, multidisciplinary consensus for the diagnosis and management of spinal cord compression among patients with mucopolysaccharidosis VI.

    PubMed

    Solanki, Guirish A; Alden, Tord D; Burton, Barbara K; Giugliani, Roberto; Horovitz, Dafne D G; Jones, Simon A; Lampe, Christina; Martin, Kenneth W; Ryan, Maura E; Schaefer, Matthias K; Siddiqui, Aisha; White, Klane K; Harmatz, Paul

    2012-09-01

    Cervical cord compression is a sequela of mucopolysaccharidosis VI, a rare lysosomal storage disorder, and has devastating consequences. An international panel of orthopedic surgeons, neurosurgeons, anesthesiologists, neuroradiologists, metabolic pediatricians, and geneticists pooled their clinical expertise to codify recommendations for diagnosing, monitoring, and managing cervical cord compression; for surgical intervention criteria; and for best airway management practices during imaging or anesthesia. The recommendations offer ideal best practices but also attempt to recognize the worldwide spectrum of resource availability. Functional assessments and clinical neurological examinations remain the cornerstone for identification of early signs of myelopathy, but magnetic resonance imaging is the gold standard for identification of cervical cord compression. Difficult airways of MPS VI patients complicate the anesthetic and, thus, the surgical management of cervical cord compression. All patients with MPS VI require expert airway management during any surgical procedure. Neurophysiological monitoring of the MPS VI patient during complex spine or head and neck surgery is considered standard practice but should also be considered for other procedures performed with the patient under general anesthesia, depending on the length and type of the procedure. Surgical interventions may include cervical decompression, stabilization, or both. Specific techniques vary widely among surgeons. The onset, presentation, and rate of progression of cervical cord compression vary among patients with MPS VI. The availability of medical resources, the expertise and experience of members of the treatment team, and the standard treatment practices vary among centers of expertise. Referral to specialized, experienced MPS treatment centers should be considered for high-risk patients and those requiring complex procedures. Therefore, the key to optimal patient care is to implement best

  14. Use of Synthetic Single-Stranded Oligonucleotides as Artificial Test Soiling for Validation of Surgical Instrument Cleaning Processes

    PubMed Central

    Wilhelm, Nadja; Perle, Nadja; Simmoteit, Robert; Schlensak, Christian; Wendel, Hans P.; Avci-Adali, Meltem

    2014-01-01

    Surgical instruments are often strongly contaminated with patients' blood and tissues, possibly containing pathogens. The reuse of contaminated instruments without adequate cleaning and sterilization can cause postoperative inflammation and the transmission of infectious diseases from one patient to another. Thus, based on the stringent sterility requirements, the development of highly efficient, validated cleaning processes is necessary. Here, we use for the first time synthetic single-stranded DNA (ssDNA_ODN), which does not appear in nature, as a test soiling to evaluate the cleaning efficiency of routine washing processes. Stainless steel test objects were coated with a certain amount of ssDNA_ODN. After cleaning, the amount of residual ssDNA_ODN on the test objects was determined using quantitative real-time PCR. The established method is highly specific and sensitive, with a detection limit of 20 fg, and enables the determination of the cleaning efficiency of medical cleaning processes under different conditions to obtain optimal settings for the effective cleaning and sterilization of instruments. The use of this highly sensitive method for the validation of cleaning processes can prevent, to a significant extent, the insufficient cleaning of surgical instruments and thus the transmission of pathogens to patients. PMID:24672793

  15. Is there a role for the use of aviation assessment instruments in surgical training preparation? A feasibility study.

    PubMed

    Stolk-Vos, Aline C; Heres, Marion H; Kesteloo, Jasper; Verburg, Dick; Hiddema, Frans; Lie, Desiree A; de Korne, Dirk F

    2017-01-01

    Selection for surgical residency programmes could potentially be improved through pretraining preparation, after assessment of surgical candidates' sensorimotor skills and personality traits. Existing aviation pilot selection instruments are available to test sensorimotor skills and personality traits. This study examined selected instruments to assess medical trainees' sensorimotor skills and personality traits. Aviation's validated computer-based Computerized Pilot Aptitude and Screening System (COMPASS) and Checklist Professional Profile (CPP) were applied to 166 final year medical students during a surgical clerkship between 2013 and 2015. All trainees completed COMPASS and CPP within the prescribed 2 hours. Compared with an age-matched and gender-matched cohort of 165 pilot candidates, medical trainees scored significantly higher on eye-hand coordination (p<0.001), need for variation (p<0.001), empathy (p=0.006), helpfulness (p<0.001) and autonomy (p<0.001). Pilot candidates scored higher on eye-hand-foot coordination (p<0.001), spatial orientation (p<0.001), persuasiveness (p<0.001), stress tolerance (p<0.001), dominance (p<0.001), ambition (p<0.001) and resilience (p<0.001). Final year medical trainees from one medical school were able to complete aviation's sensorimotor skills and personality traits selection instruments within the set time frame. They scored differently from aviation trainees on selected skills and personality traits. The applicability and utility of aviation instruments to presurgical training preparation remains to be tested. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  16. An integrated approach to endoscopic instrument tracking for augmented reality applications in surgical simulation training.

    PubMed

    Loukas, Constantinos; Lahanas, Vasileios; Georgiou, Evangelos

    2013-12-01

    Despite the popular use of virtual and physical reality simulators in laparoscopic training, the educational potential of augmented reality (AR) has not received much attention. A major challenge is the robust tracking and three-dimensional (3D) pose estimation of the endoscopic instrument, which are essential for achieving interaction with the virtual world and for realistic rendering when the virtual scene is occluded by the instrument. In this paper we propose a method that addresses these issues, based solely on visual information obtained from the endoscopic camera. Two different tracking algorithms are combined for estimating the 3D pose of the surgical instrument with respect to the camera. The first tracker creates an adaptive model of a colour strip attached to the distal part of the tool (close to the tip). The second algorithm tracks the endoscopic shaft, using a combined Hough-Kalman approach. The 3D pose is estimated with perspective geometry, using appropriate measurements extracted by the two trackers. The method has been validated on several complex image sequences for its tracking efficiency, pose estimation accuracy and applicability in AR-based training. Using a standard endoscopic camera, the absolute average error of the tip position was 2.5 mm for working distances commonly found in laparoscopic training. The average error of the instrument's angle with respect to the camera plane was approximately 2°. The results are also supplemented by video segments of laparoscopic training tasks performed in a physical and an AR environment. The experiments yielded promising results regarding the potential of applying AR technologies for laparoscopic skills training, based on a computer vision framework. The issue of occlusion handling was adequately addressed. The estimated trajectory of the instruments may also be used for surgical gesture interpretation and assessment. Copyright © 2013 John Wiley & Sons, Ltd.

  17. Adverse health effects of child labor: high exposure to chromium and oxidative DNA damage in children manufacturing surgical instruments.

    PubMed

    Sughis, Muhammad; Nawrot, Tim S; Haufroid, Vincent; Nemery, Benoit

    2012-10-01

    A considerable part of the worldwide production of surgical instruments takes place in Sialkot, Pakistan. Many children work in hazardous conditions in this industry. We investigated exposure to metals and possible health effects among children working in surgical instruments manufacturing units compared with schoolchildren from the same city. In a cross-sectional study we studied a convenience sample of 104 male children (10-14 years of age) working in surgical instruments manufacturing units and 75 male children of similar age from a school in Sialkot, Pakistan. A respiratory questionnaire was administered, spirometry was performed, and blood pressure was measured. In a spot urine sample, concentrations of metals were measured by inductively coupled plasma mass spectrometry and 8-hydroxydeoxyguanosine (8OHdG, reflecting oxidative DNA damage) by ELISA. The working children reported more asthma (10% vs. 0%; p = 0.005) and dry cough at night (36% vs. 20%; p = 0.02) than did the schoolchildren, but there were no significant differences in pulmonary function or blood pressure. The urinary concentration of chromium was 35 times higher in working children [geometric mean, 23.0 µg/L; 25th-75th percentile, 8.38-58.6] than in schoolchildren [0.66 µg/L; 0.38-1.09)], and largely in excess of the occupational Biological Exposure Index for adult workers (25 µg/L). Urinary 8-OHdG concentrations were not significantly higher in working children than in schoolchildren (19.3 vs. 17.6 µg/g creatinine, p = 0.4), but were significantly correlated with urinary nickel (r = 0.41; p < 0.0001) and with a composite index of metal exposure (r = 0.46; p < 0.0001). Children working in the surgical instruments manufacturing industry had substantial exposure to several metals, especially chromium and nickel, which are established carcinogens. Exposure to nickel was associated with evidence of increased oxidative DNA damage.

  18. In vitro investigation of friction at the interface between bone and a surgical instrument.

    PubMed

    Parekh, Jugal; Shepherd, Duncan E T; Hukins, David W L; Hingley, Carl; Maffulli, Nicola

    2013-06-01

    This study investigated the friction between surgical instruments and bone to aid improvements to instrument design. The bases of orthopaedic surgical instruments are usually made of metal, especially stainless steel. Silicone elastomer was chosen as an alternate biocompatible material, which would be compliant on the bone surface when used as the base of an instrument. The coefficient of static friction was calculated at the bone/material interface in the presence of a synthetic solution that had a comparable viscosity to that of blood, to assess the friction provided by each base material. Three types of silicone elastomers with different hardnesses (Shore A hardness 23, 50 and 77) and three distinct stainless steel surfaces (obtained by spark erosion, sand blasting and surface grinding) were used to assess the friction provided by the materials on slippery bone. The bone specimens were taken from the flattest region of the femoral shaft of a bovine femur; the outer surfaces of the specimens were kept intact. In general, the stainless steel surfaces exhibited higher values of coefficient of static friction, compared to the silicone elastomer samples. The stainless steel surface finished by spark erosion (surface roughness Ra  = 8.9 ± 1.6 µm) had the highest coefficient value of 0.74 ± 0.04. The coefficient values for the silicone elastomer sample with the highest hardness (Dow Corning Silastic Q7-4780, Shore A hardness 77) was not significantly different to values provided by the stainless steel surface finished by sand blasting (surface roughness Ra  = 2.2 ± 0.1 µm) or surface grinding (surface roughness Ra  = 0.1 ± 0.0 µm). Based on the results of this study, it is concluded that silicone could be a potentially useful material for the design of bases of orthopaedic instruments that interface with bone.

  19. Cost Analysis and Surgical Site Infection Rates in Total Knee Arthroplasty Comparing Traditional vs. Single-Use Instrumentation.

    PubMed

    Siegel, Geoffrey W; Patel, Neil N; Milshteyn, Michael A; Buzas, David; Lombardo, Daniel J; Morawa, Lawrence G

    2015-12-01

    Surgical site infections (SSIs) are a significant complications in total knee arthroplasty (TKA). The purpose of this study was to evaluate if traditional vs. single-use instrumentation had an effect on SSI's. We compared SSI rates and costs of TKAs performed with single-use (449) and traditional (169) TKA instrumentation trays. Total OR Time was, on average, 30 min less when single-use instrumentation was used. SSIs decreased in the single-use group (n=1) compared to the traditional group (n=5) (P=0.006). Single-use instrumentation added $490 in initial costs; however it saved between $480 and $600. Single-use instrumentation may provide a benefit to the patient by potentially decreasing the risk of infection and reducing the overall hospital costs. Copyright © 2015 Elsevier Inc. All rights reserved.

  20. Output control of da Vinci surgical system's surgical graspers.

    PubMed

    Johnson, Paul J; Schmidt, David E; Duvvuri, Umamaheswar

    2014-01-01

    The number of robot-assisted surgeries performed with the da Vinci surgical system has increased significantly over the past decade. The articulating movements of the robotic surgical grasper are controlled by grip controls at the master console. The user interface has been implicated as one contributing factor in surgical grasping errors. The goal of our study was to characterize and evaluate the user interface of the da Vinci surgical system in controlling surgical graspers. An angular manipulator with force sensors was used to increment the grip control angle as grasper output angles were measured. Input force at the grip control was simultaneously measured throughout the range of motion. Pressure film was used to assess the maximum grasping force achievable with the endoscopic grasping tool. The da Vinci robot's grip control angular input has a nonproportional relationship with the grasper instrument output. The grip control mechanism presents an intrinsic resistant force to the surgeon's fingertips and provides no haptic feedback. The da Vinci Maryland graspers are capable of applying up to 5.1 MPa of local pressure. The angular and force input at the grip control of the da Vinci robot's surgical graspers is nonproportional to the grasper instrument's output. Understanding the true relationship of the grip control input to grasper instrument output may help surgeons understand how to better control the surgical graspers and promote fewer grasping errors. Copyright © 2014 Elsevier Inc. All rights reserved.

  1. Risk factors for unavoidable removal of instrumentation after surgical site infection of spine surgery

    PubMed Central

    Tominaga, Hiroyuki; Setoguchi, Takao; Kawamura, Hideki; Kawamura, Ichiro; Nagano, Satoshi; Abematsu, Masahiko; Tanabe, Fumito; Ishidou, Yasuhiro; Yamamoto, Takuya; Komiya, Setsuro

    2016-01-01

    Abstract Surgical site infection (SSI) after spine instrumentation is difficult to treat, and often requires removal of instrumentation. The removal of instrumentation after spine surgery is a severe complication that can lead to the deterioration of activities of daily living and poor prognosis. Although there are many reports on SSI after spine surgery, few reports have investigated the risk factors for the removal of instrumentation after spine surgery SSI. This study aimed to identify the risk factors for unavoidable removal of instrumentation after SSI of spine surgery. We retrospectively reviewed 511 patients who underwent spine surgery with instrumentation at Kagoshima University Hospital from January 2006 to December 2014. Risk factors associated with SSI were analyzed via multiple logistic regression analysis. Parameters of the group that needed instrumentation removal were compared with the group that did not require instrumentation removal using the Mann–Whitney U and Fisher's exact tests. The posterior approach was used in most cases (453 of 511 cases, 88.6%). SSI occurred in 16 of 511 cases (3.14%) of spine surgery with instrumentation. Multivariate logistic regression analysis identified 2 significant risk factors for SSI: operation time, and American Society of Anesthesiologists physical status classification ≥ 3. Twelve of the 16 patients with SSI (75%) were able to keep the instrumentation after SSI. Pseudarthrosis occurred in 2 of 4 cases (50%) after instrumentation removal. Risk factors identified for instrumentation removal after spine SSI were a greater number of past surgeries, low preoperative hemoglobin, high preoperative creatinine, high postoperative infection treatment score for the spine, and the presence of methicillin-resistant Staphylococcus aureus. In these high risk cases, attempts should be made to decrease the risk factors preoperatively, and careful postoperative monitoring should be conducted. PMID:27787365

  2. 21 CFR 882.4525 - Microsurgical instrument.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ...) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4525 Microsurgical instrument. (a) Identification. A microsurgical instrument is a nonpowered surgical instrument used in neurological microsurgery...

  3. 21 CFR 882.4525 - Microsurgical instrument.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ...) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4525 Microsurgical instrument. (a) Identification. A microsurgical instrument is a nonpowered surgical instrument used in neurological microsurgery...

  4. Sterile reprocessing of surgical instruments in low- and middle-income countries: A multicenter pilot study.

    PubMed

    O'Hara, Nathan N; Patel, Kushal R; Caldwell, Amber; Shone, Samantha; Bryce, Elizabeth A

    2015-11-01

    Surgical site infections increase the morbidity, mortality, and costs associated with surgical care. An estimated 96.2 million surgical procedures are performed in low- and middle-income countries (LMICs) each year. This pilot study assessed the steam sterilization aspect of the surgical instrument reprocessing practice in LMIC hospitals. Surgeons representing 26 hospitals in 9 different LMICs were consented to test the single most frequently used autoclave in their respective surgical departments. Participants conducted 10 chemical integrator tests and recorded the total cycle time, exposure temperature, and pressure on each test. Data were analyzed with descriptive statistics and reviewed by medical reprocessing experts. Nine of the 26 (35%) study sites representing 7 countries returned their autoclave data and test strips (n = 90). Of the sites, 78% obtained acceptable readings on all 10 tests. When the data were compared against the recommended parameters for sterility, the results were less favorable. All 90 tests had at least 1 variable not within the target exposure time, temperature, or pressure. This pilot study presents concerns in regard to the effectiveness of steam autoclaves used in LMIC hospitals and the subsequent risks this presents to surgical patients. We acknowledge the resource limitations in many LMIC hospitals. However, the international medical community must ensure that basic sterile practice guidelines are adhered to despite these constraints. Copyright © 2015 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  5. Adverse Health Effects of Child Labor: High Exposure to Chromium and Oxidative DNA Damage in Children Manufacturing Surgical Instruments

    PubMed Central

    Sughis, Muhammad; Nawrot, Tim S.; Haufroid, Vincent

    2012-01-01

    Background: A considerable part of the worldwide production of surgical instruments takes place in Sialkot, Pakistan. Many children work in hazardous conditions in this industry. Objective: We investigated exposure to metals and possible health effects among children working in surgical instruments manufacturing units compared with schoolchildren from the same city. Methods: In a cross-sectional study we studied a convenience sample of 104 male children (10–14 years of age) working in surgical instruments manufacturing units and 75 male children of similar age from a school in Sialkot, Pakistan. A respiratory questionnaire was administered, spirometry was performed, and blood pressure was measured. In a spot urine sample, concentrations of metals were measured by inductively coupled plasma mass spectrometry and 8-hydroxydeoxyguanosine (8OHdG, reflecting oxidative DNA damage) by ELISA. Results: The working children reported more asthma (10% vs. 0%; p = 0.005) and dry cough at night (36% vs. 20%; p = 0.02) than did the schoolchildren, but there were no significant differences in pulmonary function or blood pressure. The urinary concentration of chromium was 35 times higher in working children [geometric mean, 23.0 µg/L; 25th–75th percentile, 8.38–58.6] than in schoolchildren [0.66 µg/L; 0.38–1.09)], and largely in excess of the occupational Biological Exposure Index for adult workers (25 µg/L). Urinary 8-OHdG concentrations were not significantly higher in working children than in schoolchildren (19.3 vs. 17.6 µg/g creatinine, p = 0.4), but were significantly correlated with urinary nickel (r = 0.41; p < 0.0001) and with a composite index of metal exposure (r = 0.46; p < 0.0001). Conclusions: Children working in the surgical instruments manufacturing industry had substantial exposure to several metals, especially chromium and nickel, which are established carcinogens. Exposure to nickel was associated with evidence of increased oxidative DNA damage. PMID

  6. Achieving a predictable 24-hour return to normal activities after breast augmentation: part II. Patient preparation, refined surgical techniques, and instrumentation.

    PubMed

    Tebbetts, John B

    2006-12-01

    The goal of this study was to develop practices that would allow patients undergoing subpectoral augmentation to predictably return to full normal activities within 24 hours after the operation, free of postoperative adjuncts. Part I of this study used motion and time study principles to reduce operative times, medication dosages, perioperative morbidity, and recovery times in augmentation mammaplasty. Part II of the study focuses on details of patient education, preoperative planning, instrumentation, and surgical technique modifications that were identified, modified, and implemented to achieve the results reported in part I. Two groups of 16 patients each (groups 1 and 2) were studied retrospectively for comparison to a third group of 627 patients (group 3) studied prospectively. Patients in group 1 had axillary partial retropectoral breast augmentations in 1982-1983, using dissociative anesthesia, blunt instrument implant pocket dissection, and Dow Corning, double-lumen implants containing 20 mg of methylprednisolone and 20 cc of saline in the outer lumen of the implants. Patients in group 2 (1990) had inframammary, retromammary augmentations by using a combination of blunt and electrocautery dissection, Surgitek Replicon polyurethane-covered, silicone gel-filled implants, and general endotracheal anesthesia. Patients in group 3 (1998 to 2001, n = 627) had inframammary partial retropectoral, inframammary retromammary, and axillary partial retropectoral augmentations under general endotracheal anesthesia. Refined practices and surgical techniques from studies of groups 1 and 2 were applied in group 3. Videotapes from operative procedures of groups 1 and 2 were analyzed with macromotion and micromotion study principles, and tables of events were formulated for each move during the operation for all personnel in the operating room. Extensive details of surgical technique were examined and reexamined in 13 different stages by using principles of motion and time

  7. Achieving a predictable 24-hour return to normal activities after breast augmentation: Part II. Patient preparation, refined surgical techniques, and instrumentation.

    PubMed

    Tebbetts, John B

    2002-01-01

    The goal of this study was to develop practices that would allow patients undergoing subpectoral augmentation to predictably return to full normal activities within 24 hours after the operation, free of postoperative adjuncts. Part I of this study used motion and time study principles to reduce operative times, medication dosages, perioperative morbidity, and recovery times in augmentation mammaplasty. Part II of the study focuses on details of patient education, preoperative planning, instrumentation, and surgical technique modifications that were identified, modified, and implemented to achieve the results reported in part I. Two groups of 16 patients each (groups 1 and 2) were studied retrospectively for comparison to a third group of 627 patients (group 3) studied prospectively. Patients in group 1 had axillary partial retropectoral breast augmentations in 1982-1983, using dissociative anesthesia, blunt instrument implant pocket dissection, and Dow Corning, double-lumen implants containing 20 mg of methylprednisolone and 20 cc of saline in the outer lumen of the implants. Patients in group 2 (1990) had inframammary, retromammary augmentations by using a combination of blunt and electrocautery dissection, Surgitek Replicon polyurethane-covered, silicone gel-filled implants, and general endotracheal anesthesia. Patients in group 3 (1998 to 2001, n = 627) had inframammary partial retropectoral, inframammary retromammary, and axillary partial retropectoral augmentations under general endotracheal anesthesia. Refined practices and surgical techniques from studies of groups 1 and 2 were applied in group 3. Videotapes from operative procedures of groups 1 and 2 were analyzed with macromotion and micromotion study principles, and tables of events were formulated for each move during the operation for all personnel in the operating room. Extensive details of surgical technique were examined and reexamined in 13 different stages by using principles of motion and time

  8. Effect of Surgical Approach on Pulmonary Function in Adolescent Idiopathic Scoliosis Patients: A Systemic Review and Meta-analysis.

    PubMed

    Lee, Andy C H; Feger, Mark A; Singla, Anuj; Abel, Mark F

    2016-11-15

    Systemic review and meta-analysis. To analyze the effect of spinal fusion and instrumentation for adolescent idiopathic scoliosis (AIS) on absolute pulmonary function test (PFTs). Pulmonary function is correlated with severity of deformity in AIS patients and studies that have analyzed the effect of spinal fusion and instrumentation on PFTs for AIS have reported inconsistent results. There is a need to analyze the effect of spinal fusion on PFTs with stratification by surgical approach. Our analysis included 22 studies. Cohen's d effect sizes were calculated for absolute PFT outcome measures with 95% confidence intervals (CI). Meta-analyses were performed at each postoperative time frame for six homogeneous surgical approaches: (i) combined anterior release and posterior fusion with instrumentation; (ii) combined video assisted anterior release and posterior fusion with instrumentation without thoracoplasty; (iii) posterior fusion with instrumentation without thoracoplasty; (iv) anterior fusion with instrumentation and without thoracoplasty; (v) video assisted anterior fusion with instrumentation without thoracoplasty; and (vi) any scoliosis surgery with additional thoracoplasty. Anterior spinal fusion with instrumentation, any scoliosis surgery with concomitant thoracoplasty, or video-assisted anterior fusion with instrumentation for AIS had similar absolute PFTs at their 2 year postoperative follow up compared with their preoperative PFTs (effect sizes ranging from -0.2-0.2 with all CI crossing "0"). Posterior spinal fusion with instrumentation (with or without an anterior release) demonstrated small to moderate increases in PFTs 2 years postoperatively (effect sizes ranging from 0.35-0.65 with all CI not crossing "0"). Anterior fusion with instrumentation, regardless of the approach, and any scoliosis surgery with concomitant thoracoplasty do not lead to significant change in pulmonary functions 2 year after surgery. Posterior spinal fusion with instrumentation

  9. Clinical evaluation of complete solo surgery with the "ViKY®" robotic laparoscope manipulator.

    PubMed

    Takahashi, Masahiro; Takahashi, Masanori; Nishinari, Naoto; Matsuya, Hideki; Tosha, Tsutomu; Minagawa, Yukihiro; Shimooki, Osamu; Abe, Tadashi

    2017-02-01

    Advancement in both surgical technique and medical equipment has enabled solo surgery. ViKY ® Endoscope Positioning System (ViKY ® ) is a robotic system that remotely controls an endoscope and provides direct vision control to the surgeon. Here, we report our experience with ViKY ® -assisted solo surgery. We retrospectively examined 25 cases of solo surgery TAPP with ViKY ® . ViKY ® was setup by the surgeon alone, and the setup duration was determined as the time at which the side rail was positioned and that when the endoscope was installed. For assessing the control unit, the number of false movements was counted. We compared the operative results between ViKY ® -assisted solo surgery TAPP and the conventional method with an assistant. The average time to set up ViKY ® was 7.9 min. The average number of commands for ViKY ® during surgery was 98.3, and the average number of errors and no response of control unit was 7.9. The mean duration of surgery was 136 min for the ViKY ® group, including the setup time, and 117 min for the conventional method. No case required an assistant during the operation. There was also no difference between the two groups with regard to postoperative complications and the rate of recurrence. ViKY ® proved reliable in recognizing orders with very few failures, and the operations were performed safely and were comparable to the conventional operations with assistants. Solo surgery with ViKY ® was beneficial in this clinical evaluation.

  10. Surgeons and their tools: a history of surgical instruments and their innovators--Part II: The surgeon's wand-evolution from knife to scalpel to electrocautery.

    PubMed

    El-Sedfy, Abraham; Chamberlain, Ronald S

    2014-12-01

    This is the second of five articles reviewing the historical origins of some of the more commonly used surgical instruments and takes "time out" to remind current surgeons about the surgical pioneers on whose shoulders they now stand and whose inventions they now use.

  11. Aeronautic Instruments. Section VI : Aerial Navigation and Navigating Instruments

    NASA Technical Reports Server (NTRS)

    Eaton, H N

    1923-01-01

    This report outlines briefly the methods of aerial navigation which have been developed during the past few years, with a description of the different instruments used. Dead reckoning, the most universal method of aerial navigation, is first discussed. Then follows an outline of the principles of navigation by astronomical observation; a discussion of the practical use of natural horizons, such as sea, land, and cloud, in making extant observations; the use of artificial horizons, including the bubble, pendulum, and gyroscopic types. A description is given of the recent development of the radio direction finder and its application to navigation.

  12. Segmental Pedicle Screw Instrumentation and Fusion Only to L5 in the Surgical Treatment of Flaccid Neuromuscular Scoliosis.

    PubMed

    Takaso, Masashi; Nakazawa, Toshiyuki; Imura, Takayuki; Fukuda, Michinari; Takahashi, Kazuhisa; Ohtori, Seiji

    2018-03-01

    A retrospective cohort study was performed. The purpose of this study was to determine the efficacy and safety of stopping segmental pedicle screw instrumentation constructs at L5 in the treatment of neuromuscular scoliosis. Duchenne muscular dystrophy and spinal muscular atrophy are flaccid neuromuscular disorders in which gradual deterioration is the hallmark and have a lot of characteristics in common despite differences in etiology. Instrumentation and fusion to the sacrum/pelvis has been a mainstay in the surgical treatment of flaccid neuromuscular scoliosis and recommended to correct pelvic obliquity. However, the caudal extent of instrumentation and fusion in the surgical treatment of flaccid neuromuscular scoliosis has remained a matter of considerable debate and there have been few studies on the use of segmental pedicle screw instrumentation for flaccid neuromuscular scoliosis. From 2005 to 2007, a total of 27 consecutive patients with neuromuscular disorders (20 Duchenne muscular dystrophy and 7 spinal muscular atrophy), aged 11 to 17 years, underwent segmental pedicle screw instrumentation and fusion only to L5. Assessment was performed clinically and with radiologic measurements. Minimum 2-year follow-up was required for inclusion in this study. Twenty patients were enrolled in this study. No patient was lost to follow-up. All patients had L5 tilt of less than 15° and a coronal curve with apex L2 or higher preoperatively. Preoperative coronal curve averaged 70° (range: 51°-88°), with a postoperative mean of 15° (range: 5°-25°) and 17° (range: 6°-27°) at the last follow-up. The pelvic obliquity improved from 15° (range: 9°-25°) preoperatively to 5° (range: 3°-8°) postoperatively and 6° (range: 3°-8°) at the last follow-up. The L5 tilt improved from 9° (range: 2°-14°) preoperatively to 2° (range: 0°-4°) postoperatively and 2° (range: 0°-5°) at the last follow-up. Physiologic sagittal plane alignment was recreated after surgery

  13. Surgical Borescopes Remove Contaminants

    NASA Technical Reports Server (NTRS)

    Vallow, K.

    1987-01-01

    Borescope instruments put to use in extracting hard-to-reach particles. Surgical instruments in flexible borescopes used for removing contaminant particles from normally inaccessible places within equipment. Instruments readily enter small openings, turn corners, and reach far.

  14. Combining of ETHOS Operating Ergonomic Platform, Three-dimensional Laparoscopic Camera, and Radius Surgical System Manipulators Improves Ergonomy in Urologic Laparoscopy: Comparison with Conventional Laparoscopy and da Vinci in a Pelvi Trainer.

    PubMed

    Tokas, Theodoros; Gözen, Ali Serdar; Avgeris, Margaritis; Tschada, Alexandra; Fiedler, Marcel; Klein, Jan; Rassweiler, Jens

    2017-10-01

    Posture, vision, and instrumentation limitations are the main predicaments of conventional laparoscopy. To combine the ETHOS surgical chair, the three-dimensional laparoscope, and the Radius Surgical System manipulators, and compare the system with conventional laparoscopy and da Vinci in terms of task completion times and discomfort. Fifteen trainees performed the three main laparoscopic suturing tasks of the Heilbronn training program (IV: simulation of dorsal venous complex suturing; V: circular suturing of tubular structure; and VI: urethrovesical anastomosis) in a pelvi trainer. The tasks were performed conventionally, utilizing the three devices, and robotically. Task completion times were recorded and the surgeon discomfort was evaluated using questionnaires. Task completion times were compared using nonparametric Wilcoxon signed rank test and ergonomic scores were compared using Pearson chi-square test. The use of the full laparoscopic set (ETHOS chair, three-dimensional laparoscopic camera, Radius Surgical System needle holders), resulted in a significant improvement of the completion time of the three tested tasks compared with conventional laparoscopy (p<0.001) and similar to da Vinci surgery. After completing Tasks IV, V, and VI conventionally, 12 (80%), 13 (86.7%), and 13 (86.7%) of the 15 trainees, respectively, reported heavy total discomfort. The full laparoscopic system nullified heavy discomfort for Tasks IV and V and minimized it (6.7%) for the most demanding Task VI. Especially for Task VI, all trainees gained benefit, by using the system, in terms of task completion times and discomfort. The limited trainee robotic experience and the questionnaire subjectivity could be a potential limitation. The ergonomic laparoscopic system offers significantly improved task completion times and ergonomy than conventional laparoscopy. Furthermore, it demonstrates comparable results to robotic surgery. The study was conducted in a pelvi trainer and no patients

  15. Intraocular biopsy using special forceps: a new instrument and refined surgical technique.

    PubMed

    Akgul, Harun; Otterbach, Friedrich; Bornfeld, Norbert; Jurklies, Bernhard

    2011-01-01

    The aim was to investigate the Essen biopsy forceps as a new instrument and surgical approach for biopsy of intraocular tumours. Biopsy is indicated for assessment of any uncertain intraocular process or confirmation for presumed diagnosis before treatment. There is increasing interest for further genetic and immunocytological information in order to characterise the neoplasm, especially grading and prognosis of micrometastasis in uveal melanoma. The authors have developed a new surgical technique using special intraocular biopsy forceps. Twenty patients with uncertain intraocular subretinal tumour underwent biopsies carried out using the special Essen biopsy forceps. Biopsies were obtained through sutureless 23-gauge three-port vitrectomy. A small retinotomy tumour specimen was taken by the forceps branches. For further processing, the specimens were flushed out into a sterile tube and then sent to pathologists. The prebioptical tumour had a mean thickness of 3.48 mm (1.1 to 9.8 mm). In all cases (n=20) biopsies (0.3-2.1 mm in size) were obtained, in 19 cases (95%) allowing precise histological and immunohistochemical typing of the lesions following cytoblock embedding. Uveal melanoma was diagnosed in 50% (n=10), choroidal metastasis in 15% (n=3) and choroidal naevus in 15% (n=3); other diagnoses (n=3) included choroidal haemangioma, B cell lymphoma and old subretinal haemorrhage. Apart from three patients with temporary punctual bleeding on the surface, there were no intra- and postoperative complications. Biopsy using special forceps is a promising new approach and precise surgical procedure. Especially for small intraocular tumours, this technique has the advantage in providing enough tissue for improved histological examination and presenting a low risk for complications.

  16. Instrument Failures for the da Vinci Surgical System: a Food and Drug Administration MAUDE Database Study.

    PubMed

    Friedman, Diana C W; Lendvay, Thomas S; Hannaford, Blake

    2013-05-01

    Our goal was to analyze reported instances of the da Vinci robotic surgical system instrument failures using the FDA's MAUDE (Manufacturer and User Facility Device Experience) database. From these data we identified some root causes of failures as well as trends that may assist surgeons and users of the robotic technology. We conducted a survey of the MAUDE database and tallied robotic instrument failures that occurred between January 2009 and December 2010. We categorized failures into five main groups (cautery, shaft, wrist or tool tip, cable, and control housing) based on technical differences in instrument design and function. A total of 565 instrument failures were documented through 528 reports. The majority of failures (285) were of the instrument's wrist or tool tip. Cautery problems comprised 174 failures, 76 were shaft failures, 29 were cable failures, and 7 were control housing failures. Of the reports, 10 had no discernible failure mode and 49 exhibited multiple failures. The data show that a number of robotic instrument failures occurred in a short period of time. In reality, many instrument failures may go unreported, thus a true failure rate cannot be determined from these data. However, education of hospital administrators, operating room staff, surgeons, and patients should be incorporated into discussions regarding the introduction and utilization of robotic technology. We recommend institutions incorporate standard failure reporting policies so that the community of robotic surgery companies and surgeons can improve on existing technologies for optimal patient safety and outcomes.

  17. The influence of different sets of surgical instrumentation in Oxford UKA on bearing size and component position.

    PubMed

    Walker, Tilman; Heinemann, Pascal; Bruckner, Thomas; Streit, Marcus R; Kinkel, Stefan; Gotterbarm, Tobias

    2017-07-01

    The Oxford unicompartmental knee arthroplasty (OUKA) has been proven to be an effective treatment for anteromedial osteoarthritis of the knee joint. New instrumentation has been introduced to improve the reproducibility of implant positioning and to minimize bone loss during tibial resection (Oxford Microplasty; Zimmer Biomet, Warsaw, Indiana, USA). To assess the effect of the new instrumentation, we retrospectively evaluated the postoperative radiographs and surgical records of 300 OUKAs in three consecutive cohorts of patients. The first cohort consists of the first 100 minimal invasive implantations of the OUKA using the conventional phase III instrumentation, the second cohort consists of the 100 most recent minimal invasive OUKA with the conventional phase III instrumentation and the third cohort consists of the first 100 minimal invasive OUKA using the new Oxford Microplasty instrumentation. Mean bearing thickness was statistically significant and lower in OUKA with use of the updated instrumentation than with the conventional instrumentation (p = 0.01 and p = 0.04). Additionally, statistically significant and more femoral components were aligned within the accepted range of tolerance in both the coronal and the sagittal plane with use of the updated instrumentation compared to the conventional phase III instrumentation in group A (p = 0.029 and p = 0.038) and in the sagittal plane with use of the updated instrumentation compared to the conventional phase III instrumentation in group B (p = 0.002). The new modified instrumentation seems to be an effective tool to reduce the risk of malalignment of the femoral component in the coronal and in the sagittal plane compared to the conventional phase III instrumentation. Furthermore, the instrumentation is also effective in determining an adequate level of tibial resection and thus avoiding unnecessary bone loss.

  18. Surgical smoke.

    PubMed

    Fan, Joe King-Man; Chan, Fion Siu-Yin; Chu, Kent-Man

    2009-10-01

    Surgical smoke is the gaseous by-product formed during surgical procedures. Most surgeons, operating theatre staff and administrators are unaware of its potential health risks. Surgical smoke is produced by various surgical instruments including those used in electrocautery, lasers, ultrasonic scalpels, high speed drills, burrs and saws. The potential risks include carbon monoxide toxicity to the patient undergoing a laparoscopic operation, pulmonary fibrosis induced by non-viable particles, and transmission of infectious diseases like human papilloma virus. Cytotoxicity and mutagenicity are other concerns. Minimisation of the production of surgical smoke and modification of any evacuation systems are possible solutions. In general, a surgical mask can provide more than 90% protection to exposure to surgical smoke; however, in most circumstances it cannot provide air-tight protection to the user. An at least N95 grade or equivalent respirator offers the best protection against surgical smoke, but whether such protection is necessary is currently unknown.

  19. Eponymous Instruments in Orthopaedic Surgery

    PubMed Central

    Buraimoh, M. Ayodele; Liu, Jane Z.; Sundberg, Stephen B.; Mott, Michael P.

    2017-01-01

    Abstract Every day surgeons call for instruments devised by surgeon trailblazers. This article aims to give an account of commonly used eponymous instruments in orthopaedic surgery, focusing on the original intent of their designers in order to inform how we use them today. We searched PubMed, the archives of longstanding medical journals, Google, the Internet Archive, and the HathiTrust Digital Library for information regarding the inventors and the developments of 7 instruments: the Steinmann pin, Bovie electrocautery, Metzenbaum scissors, Freer elevator, Cobb periosteal elevator, Kocher clamp, and Verbrugge bone holding forceps. A combination of ingenuity, necessity, circumstance and collaboration produced the inventions of the surgical tools numbered in our review. In some cases, surgical instruments were improvements of already existing technologies. The indications and applications of the orthopaedic devices have changed little. Meanwhile, instruments originally developed for other specialties have been adapted for our use. Although some argue for a transition from eponymous to descriptive terms in medicine, there is value in recognizing those who revolutionized surgical techniques and instrumentation. Through history, we have an opportunity to be inspired and to better understand our tools. PMID:28852360

  20. Is hospital information system relevant to detect surgical site infection? Findings from a prospective surveillance study in posterior instrumented spinal surgery.

    PubMed

    Boetto, J; Chan-Seng, E; Lonjon, G; Pech, J; Lotthé, A; Lonjon, N

    2015-11-01

    Spinal instrumentation has a high rate of surgical site infection (SSI), but results greatly vary depending on surveillance methodology, surgical procedures, or quality of follow-up. Our aim was to study true incidence of SSI in spinal surgery by significant data collection, and to compare it with the results obtained through the hospital information system. This work is a single center prospective cohort study that included all patients consecutively operated on for spinal instrumentation by posterior approach over a six-month period regardless the etiology. For all patients, a "high definition" prospective method of surveillance was performed by the infection control (IC) department during at least 12 months after surgery. Results were then compared with findings from automatic surveillance though the hospital information system (HIS). One hundred and fifty-four patients were included. We found no hardly difference between "high definition" and automatic surveillance through the HIS, even if HIS tended to under-estimate the infection rate: rate of surgical site infection was 2.60% and gross SSI incidence rate via the hospital information system was 1.95%. Smoking and alcohol consumption were significantly related to a SSI. Our SSI rates to reflect the true incidence of infectious complications in posterior instrumented adult spinal surgery in our hospital and these results were consistent with the lower levels of published infection rate. In-house surveillance by surgeons only is insufficiently sensitive. Further studies with more patients and a longer inclusion time are needed to conclude if SSI case detection through the HIS could be a relevant and effective alternative method. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  1. Design of a Channel Error Simulator using Virtual Instrument Techniques for the Initial Testing of TCP/IP and SCPS Protocols

    NASA Technical Reports Server (NTRS)

    Horan, Stephen; Wang, Ru-Hai

    1999-01-01

    There exists a need for designers and developers to have a method to conveniently test a variety of communications parameters for an overall system design. This is no different when testing network protocols as when testing modulation formats. In this report, we discuss a means of providing a networking test device specifically designed to be used for space communications. This test device is a PC-based Virtual Instrument (VI) programmed using the LabVIEW(TM) version 5 software suite developed by National Instruments(TM)TM. This instrument was designed to be portable and usable by others without special, additional equipment. The programming was designed to replicate a VME-based hardware module developed earlier at New Mexico State University (NMSU) and to provide expanded capabilities exceeding the baseline configuration existing in that module. This report describes the design goals for the VI module in the next section and follows that with a description of the design of the VI instrument. This is followed with a description of the validation tests run on the VI. An application of the error-generating VI to networking protocols is then given.

  2. Does the Type of Metal Instrumentation Affect the Risk of Surgical Site Infection in Pediatric Scoliosis Surgery?

    PubMed

    Wright, Margaret L; Skaggs, David L; Matsumoto, Hiroko; Woon, Regina P; Trocle, Ashley; Flynn, John M; Vitale, Michael G

    2016-05-01

    Retrospective cohort study. To determine the association of implant metal composition with the risk of surgical site infection (SSI) following pediatric spine surgery. SSI is a well-described complication following pediatric spine surgery. Many risk factors have been identified in the literature, but controversy remains regarding metal composition as a risk factor. This was a retrospective study of patients who underwent posterior spinal instrumentation procedures between January 1, 2006, and December 31, 2008, at three large children's hospitals for any etiology of scoliosis and had at least 1 year of postoperative follow-up. Procedures included posterior spinal fusion, growth-friendly instrumentation, and revision of spinal instrumentation. The Centers for Disease Control and Prevention definition of SSI was used. A chi-squared test was performed to determine the relationship between type of metal instrumentation and development of an SSI. The study included 874 patients who underwent 1,156 total procedures. Overall, 752 (65%) procedures used stainless steel instrumentation, 238 (21%) procedures used titanium instrumentation, and the remaining 166 (14%) procedures used cobalt chrome and titanium hybrid instrumentation. The overall risk of infection was 6.1% (70/1,156) per procedure, with 5.9% (44/752) for stainless steel, 6.7% (12/238) for titanium, and 6.0% (10/166) for cobalt chrome. The multiple regression analysis found no significant differences in the metal type used between patients with and without infection (p = .886) adjusting for etiology, instrumentation to pelvis, and type of procedures. When stratified based on etiology, the multiple regression analyses also found no significant difference in SSI between two metal type groups. This study found no difference in risk of infection with stainless steel, titanium, or cobalt chrome/titanium instrumentation and is adequately powered to detect a true difference in risk of SSI. Level II, prognostic

  3. A development of assistant surgical robot system based on surgical-operation-by-wire and hands-on-throttle-and-stick.

    PubMed

    Kim, Myungjoon; Lee, Chiwon; Park, Woo Jung; Suh, Yun Suhk; Yang, Han Kwang; Kim, H Jin; Kim, Sungwan

    2016-05-20

    Robot-assisted laparoscopic surgery offers several advantages compared with open surgery and conventional minimally invasive surgery. However, one issue that needs to be resolved is a collision between the robot arm and the assistant instrument. This is mostly caused by miscommunication between the surgeon and the assistant. To resolve this limitation, an assistant surgical robot system that can be simultaneously manipulated via a wireless controller is proposed to allow the surgeon to control the assistant instrument. The system comprises two novel master interfaces (NMIs), a surgical instrument with a gripper actuated by a micromotor, and 6-axis robot arm. Two NMIs are attached to master tool manipulators of da Vinci research kit (dVRK) to control the proposed system simultaneously with patient side manipulators of dVRK. The developments of the surgical instrument and NMI are based on surgical-operation-by-wire concept and hands-on-throttle-and-stick concept from the earlier research, respectively. Tests for checking the accuracy, latency, and power consumption of the NMI are performed. The gripping force, reaction time, and durability are assessed to validate the surgical instrument. The workspace is calculated for estimating the clinical applicability. A simple peg task using the fundamentals of laparoscopic surgery board and an in vitro test are executed with three novice volunteers. The NMI was operated for 185 min and reflected the surgeon's decision successfully with a mean latency of 132 ms. The gripping force of the surgical instrument was comparable to that of conventional systems and was consistent even after 1000 times of gripping motion. The reaction time was 0.4 s. The workspace was calculated to be 8397.4 cm(3). Recruited volunteers were able to execute the simple peg task within the cut-off time and successfully performed the in vitro test without any collision. Various experiments were conducted and it is verified that the proposed assistant

  4. Posterior Rigid Instrumentation of C7: Surgical Considerations and Biomechanics at the Cervicothoracic Junction. A Review of the Literature.

    PubMed

    Bayoumi, Ahmed B; Efe, Ibrahim E; Berk, Selim; Kasper, Ekkehard M; Toktas, Zafer Orkun; Konya, Deniz

    2018-03-01

    The cervicothoracic junction is a challenging anatomic transition in spine surgery. It is commonly affected by different types of diseases that may significantly impair stability in this region. The seventh cervical vertebra (C7) is an atypical cervical vertebra with unique anatomic features compared to subaxial cervical spine (C3 to C6). C7 has relatively broader laminae, larger pedicles, smaller lateral masses, and a long nonbifid spinous process. These features allow a variety of surgical methods for performing posterior rigid instrumentation in the form of different types of screws, such as lateral mass screws, pedicle screws, transfacet screws, and intralaminar screws. Many biomechanical studies on cadavers have evaluated and compared different types of implants at C7. We reviewed PubMed/Medline by using specific combinations of keywords to summarize previously published articles that examined C7 posterior rigid instrumentation thoroughly in an experimental fashion on patients or cadavers with additional descriptive radiologic parameters for evaluation of the optimum surgical technique for each type. A total of 44 articles were reported, including 22 articles that discussed anatomic considerations (entry points, sagittal and axial trajectories, and features of screws) and another 22 articles that discussed the relevant biomechanical testing at this transitional region if C7 was directly involved in terms of receiving posterior rigid implants. C7 can accommodate different types of screws, which can provide additional benefits and risks based on availability of bony purchase, awareness of surgical technique, biomechanics, and anatomic considerations. Copyright © 2017 Elsevier Inc. All rights reserved.

  5. Development of an intelligent surgical training system for Thoracentesis.

    PubMed

    Nakawala, Hirenkumar; Ferrigno, Giancarlo; De Momi, Elena

    2018-01-01

    Surgical training improves patient care, helps to reduce surgical risks, increases surgeon's confidence, and thus enhances overall patient safety. Current surgical training systems are more focused on developing technical skills, e.g. dexterity, of the surgeons while lacking the aspects of context-awareness and intra-operative real-time guidance. Context-aware intelligent training systems interpret the current surgical situation and help surgeons to train on surgical tasks. As a prototypical scenario, we chose Thoracentesis procedure in this work. We designed the context-aware software framework using the surgical process model encompassing ontology and production rules, based on the procedure descriptions obtained through textbooks and interviews, and ontology-based and marker-based object recognition, where the system tracked and recognised surgical instruments and materials in surgeon's hands and recognised surgical instruments on the surgical stand. The ontology was validated using annotated surgical videos, where the system identified "Anaesthesia" and "Aspiration" phase with 100% relative frequency and "Penetration" phase with 65% relative frequency. The system tracked surgical swab and 50mL syringe with approximately 88.23% and 100% accuracy in surgeon's hands and recognised surgical instruments with approximately 90% accuracy on the surgical stand. Surgical workflow training with the proposed system showed equivalent results as the traditional mentor-based training regime, thus this work is a step forward a new tool for context awareness and decision-making during surgical training. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Maximizing coupling strength of magnetically anchored surgical instruments: how thick can we go?

    PubMed

    Best, Sara L; Bergs, Richard; Gedeon, Makram; Paramo, Juan; Fernandez, Raul; Cadeddu, Jeffrey A; Scott, Daniel J

    2011-01-01

    The Magnetic Anchoring and Guidance System (MAGS) includes an external magnet that controls intra-abdominal surgical instruments via magnetic attraction forces. We have performed NOTES (Natural Orifice Transluminal Endoscopic Surgery) and LESS (Laparoendoscopic Single Site) procedures using MAGS instruments in porcine models with up to 2.5-cm-thick abdominal walls, but this distance may not be sufficient in some humans. The purpose of this study was to determine the maximal abdominal wall thickness for which the current MAGS platform is suitable. Successive iterations of prototype instruments were developed; those evaluated in this study include external (134-583 g, 38-61 mm diameter) and internal (8-39 g, 10-22 mm diameter) components using various grades, diameters, thicknesses, and stacking/shielding/focusing configurations of permanent Neodymium-iron-boron (NdFeB) magnets. Nine configurations were tested for coupling strength across distances of 0.1-10 cm. The force-distance tests across an air medium were conducted at 0.5-mm increments using a robotic arm fitted with a force sensor. A minimum theoretical instrument drop-off (decoupling) threshold was defined as the separation distance at which force decreased below the weight of the heaviest internal component (39 g). Magnetic attraction forces decreased exponentially over distance. For the nine configurations tested, the average forces were 3,334 ± 1,239 gf at 0.1 cm, 158 ± 98 gf at 2.5 cm, and 8.7 ± 12 gf at 5 cm; the drop-off threshold was 3.64 ± 0.8 cm. The larger stacking configurations and magnets yielded up to a 592% increase in attraction force at 2.5 cm and extended the drop-off threshold distance by up to 107% over single-stack anchors. For the strongest configuration, coupling force ranged from 5,337 gf at 0.1 cm to 0 gf at 6.95 cm and yielded a drop-off threshold distance of 4.78 cm. This study suggests that the strongest configuration of currently available MAGS instruments is suitable for

  7. Biomechanical risk factors for proximal junctional kyphosis: a detailed numerical analysis of surgical instrumentation variables.

    PubMed

    Cammarata, Marco; Aubin, Carl-Éric; Wang, Xiaoyu; Mac-Thiong, Jean-Marc

    2014-04-15

    Biomechanical analysis of proximal junctional kyphosis (PJK) through computer simulations and sensitivity analysis. To gain biomechanical knowledge on the risk of PJK and find surgical solutions to reduce the risks. PJK is a pathological kyphotic deformity adjacent to the instrumentation. Clinical studies have documented its risk factors, but still little is known on how it is correlated with various individual instrumentation variables. Biomechanical spine models of 6 patients with adult scoliosis were developed, validated, and then used to perform 576 simulations, varying the proximal dissection procedure, the implant type at the upper instrumented vertebra, the sagittal rod curvature, and the proximal diameter of the proximal transition rods. Four biomechanical indices--the proximal junctional kyphotic angle, thoracic kyphosis, proximal flexion force, and proximal flexion moment--were assessed. The bilateral complete facetectomy, the posterior ligaments resection, and the combination of both increased the proximal junctional kyphotic angle (respectively, by 10%, 28% and 53%) and the proximal flexion force (4%, 12%, and 22%) and moment (16%, 44%, and 83%). Compared with pedicle screws at upper instrumented vertebra, proximal transverse process hooks reduced the 3 biomechanical indices by approximately 26%. The use of proximal transition rods with reduced proximal diameter from 5.5 mm to 4 mm decreased the proximal junctional kyphotic angle (by 6%) and the proximal flexion force (4%) and moment (8%). The increase of the sagittal rod curvature from 10° to 20°, 30°, and 40° increased the proximal junctional kyphotic angle (by 6%, 13%, and 19%) and the proximal flexion force (3%, 7%, and 10%) and moment (9%, 18%, and 27%). Preserving more posterior proximal intervertebral elements, the use of transition rods and transverse process hooks at upper instrumented vertebra, and reducing the global sagittal rod curvature each decreased the 4 biomechanical indices that

  8. Effect of hand hygiene and glove use on cleanliness of reusable surgical instruments.

    PubMed

    Costa, D M; Lopes, L K O; Tipple, A F V; Castillo, R B; Hu, H; Deva, A K; Vickery, K

    2017-12-01

    During functionality testing and packaging of reusable surgical instruments (RSI) for sterilization, instruments are frequently touched. There is a lack of standards relating to hand hygiene frequency and use of gloves in the sterilizing service unit packing area. To determine the effect of hand hygiene and glove use on maintenance of RSI cleanliness. Following manual and automated cleaning, Halsted-mosquito forceps were assessed for adenosine triphosphate (ATP), protein and microbial contamination after handling with gloved and ungloved but washed hands using an ATP surface swab test, bicinchoninic acid assay, and standard culture plate/broth, respectively. Gram's stain was used to classify the isolates. RSI contamination was assessed immediately following and 1, 2, and 4 h after washing hands. Packing instruments with hands that had been unwashed for 2 or 4 h resulted in a significant increase in contaminating ATP when compared with all other treatment groups (P < 0.05). There was a significant correlation between the time since washing hands, the amount of ATP (r = 0.93; P ≤ 0.001), and the microbial load (r = 0.83; P ≤ 0.001) contaminating the forceps, where the longer the time the hands remained unwashed the higher the contamination. Significantly more contaminating protein was found on forceps handled with ungloved hands that had not been washed for 2 or 4 h (P < 0.001). Critical RSI inspection, assembling, lubricating and packing should be performed using either gloves or within 1 h of washing hands. Copyright © 2017 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  9. NG2/CSPG4-collagen type VI interplays putatively involved in the microenvironmental control of tumour engraftment and local expansion.

    PubMed

    Cattaruzza, Sabrina; Nicolosi, Pier Andrea; Braghetta, Paola; Pazzaglia, Laura; Benassi, Maria Serena; Picci, Piero; Lacrima, Katia; Zanocco, Daniela; Rizzo, Erika; Stallcup, William B; Colombatti, Alfonso; Perris, Roberto

    2013-06-01

    In soft-tissue sarcoma patients, enhanced expression of NG2/CSPG4 proteoglycan in pre-surgical primary tumours predicts post-surgical metastasis formation and thereby stratifies patients into disease-free survivors and patients destined to succumb to the disease. Both primary and secondary sarcoma lesions also up-regulate collagen type VI, a putative extracellular matrix ligand of NG2, and this matrix alteration potentiates the prognostic impact of NG2. Enhanced constitutive levels of the proteoglycan in isolated sarcoma cells closely correlate with a superior engraftment capability and local growth in xenogenic settings. This apparent NG2-associated malignancy was also corroborated by the diverse tumorigenic behaviour in vitro and in vivo of immunoselected NG2-expressing and NG2-deficient cell subsets, by RNAi-mediated knock down of endogenous NG2, and by ectopic transduction of full-length or deletion constructs of NG2. Cells with modified expression of NG2 diverged in their interaction with purified Col VI, matrices supplemented with Col VI, and cell-free matrices isolated from wild-type and Col VI null fibroblasts. The combined use of dominant-negative NG2 mutant cells and purified domain fragments of the collagen allowed us to pinpoint the reciprocal binding sites within the two molecules and to assert the importance of this molecular interaction in the control of sarcoma cell adhesion and motility. The NG2-mediated binding to Col VI triggered activation of convergent cell survival- and cell adhesion/migration-promoting signal transduction pathways, implicating PI-3K as a common denominator. Thus, the findings point to an NG2-Col VI interplay as putatively involved in the regulation of the cancer cell-host microenvironment interactions sustaining sarcoma progression.

  10. Quantitative Analysis of Transnasal Anterior Skull Base Approach: Report of Technology for Intraoperative Assessment of Instrument Motion.

    PubMed

    Berens, Angelique M; Harbison, Richard Alex; Li, Yangming; Bly, Randall A; Aghdasi, Nava; Ferreira, Manuel; Hannaford, Blake; Moe, Kris S

    2017-08-01

    To develop a method to measure intraoperative surgical instrument motion. This model will be applicable to the study of surgical instrument kinematics including surgical training, skill verification, and the development of surgical warning systems that detect aberrant instrument motion that may result in patient injury. We developed an algorithm to automate derivation of surgical instrument kinematics in an endoscopic endonasal skull base surgery model. Surgical instrument motion was recorded during a cadaveric endoscopic transnasal approach to the pituitary using a navigation system modified to record intraoperative time-stamped Euclidian coordinates and Euler angles. Microdebrider tip coordinates and angles were referenced to the cadaver's preoperative computed tomography scan allowing us to assess surgical instrument kinematics over time. A representative cadaveric endoscopic endonasal approach to the pituitary was performed to demonstrate feasibility of our algorithm for deriving surgical instrument kinematics. Technical feasibility of automatically measuring intraoperative surgical instrument motion and deriving kinematics measurements was demonstrated using standard navigation equipment.

  11. Risk factors for unavoidable removal of instrumentation after surgical site infection of spine surgery: A retrospective case-control study.

    PubMed

    Tominaga, Hiroyuki; Setoguchi, Takao; Kawamura, Hideki; Kawamura, Ichiro; Nagano, Satoshi; Abematsu, Masahiko; Tanabe, Fumito; Ishidou, Yasuhiro; Yamamoto, Takuya; Komiya, Setsuro

    2016-10-01

    Surgical site infection (SSI) after spine instrumentation is difficult to treat, and often requires removal of instrumentation. The removal of instrumentation after spine surgery is a severe complication that can lead to the deterioration of activities of daily living and poor prognosis. Although there are many reports on SSI after spine surgery, few reports have investigated the risk factors for the removal of instrumentation after spine surgery SSI. This study aimed to identify the risk factors for unavoidable removal of instrumentation after SSI of spine surgery. We retrospectively reviewed 511 patients who underwent spine surgery with instrumentation at Kagoshima University Hospital from January 2006 to December 2014. Risk factors associated with SSI were analyzed via multiple logistic regression analysis. Parameters of the group that needed instrumentation removal were compared with the group that did not require instrumentation removal using the Mann-Whitney U and Fisher's exact tests. The posterior approach was used in most cases (453 of 511 cases, 88.6%). SSI occurred in 16 of 511 cases (3.14%) of spine surgery with instrumentation. Multivariate logistic regression analysis identified 2 significant risk factors for SSI: operation time, and American Society of Anesthesiologists physical status classification ≥ 3. Twelve of the 16 patients with SSI (75%) were able to keep the instrumentation after SSI. Pseudarthrosis occurred in 2 of 4 cases (50%) after instrumentation removal. Risk factors identified for instrumentation removal after spine SSI were a greater number of past surgeries, low preoperative hemoglobin, high preoperative creatinine, high postoperative infection treatment score for the spine, and the presence of methicillin-resistant Staphylococcus aureus. In these high risk cases, attempts should be made to decrease the risk factors preoperatively, and careful postoperative monitoring should be conducted.

  12. Endoscopic septoplasty in primary cases using electromechanical instruments: surgical technique, efficacy and results.

    PubMed

    De Sousa Fontes, Aderito; Sandrea Jiménez, Minaret; Chacaltana Ayerve, Rosa R

    2013-01-01

    The microdebrider is a surgical tool which has been used successfully in many endoscopic surgical procedures in otolaryngology. In this study, we analysed our experience using this powered instrument in the resection of obstructive nasal septum deviations. This was a longitudinal, prospective, descriptive study conducted between January and June 2007 on 141 patients who consulted for chronic nasal obstruction caused by a septal deviation or deformity and underwent powered endoscopic septoplasty (PES). The mean age was 39.9 years (15-63 years); 60.28% were male (n=85) The change in nasal symptom severity decreased after surgery from 6.12 (preoperative) to 2.01 (postoperative). Patients undergoing PES had a significant reduction of nasal symptoms in the pre- and postoperative period, which was statistically significant (P<.05). There were no statistically significant differences between the results at the 2 nd week, 6th week and 5th year after surgery. The 100% of patients were satisfied with the results of surgery and no patient answered "No" to the question added to compare patient satisfaction after surgery. Minor complications in the postoperative period were present in 4.96% of the cases. Powered endoscopic septoplasty allows accurate, conservative repair of obstructive nasal septum deviations, with fewer complications and better functional results. In our experience, this technique offered significant perioperative advantages with high postoperative patient satisfaction in terms of reducing the severity of nasal symptoms. Copyright © 2012 Elsevier España, S.L. All rights reserved.

  13. The Design of a Chemical Virtual Instrument Based on LabVIEW for Determining Temperatures and Pressures.

    PubMed

    Wang, Wen-Bin; Li, Jang-Yuan; Wu, Qi-Jun

    2007-01-01

    A LabVIEW-based self-constructed chemical virtual instrument (VI) has been developed for determining temperatures and pressures. It can be put together easily and quickly by selecting hardware modules, such as the PCI-DAQ card or serial port method, different kinds of sensors, signal-conditioning circuits or finished chemical instruments, and software modules such as data acquisition, saving, proceeding. The VI system provides individual and extremely flexible solutions for automatic measurements in physical chemistry research.

  14. The Design of a Chemical Virtual Instrument Based on LabVIEW for Determining Temperatures and Pressures

    PubMed Central

    Wang, Wen-Bin; Li, Jang-Yuan; Wu, Qi-Jun

    2007-01-01

    A LabVIEW-based self-constructed chemical virtual instrument (VI) has been developed for determining temperatures and pressures. It can be put together easily and quickly by selecting hardware modules, such as the PCI-DAQ card or serial port method, different kinds of sensors, signal-conditioning circuits or finished chemical instruments, and software modules such as data acquisition, saving, proceeding. The VI system provides individual and extremely flexible solutions for automatic measurements in physical chemistry research. PMID:17671611

  15. The development of a computer-assisted instruction system for clinical nursing skills with virtual instruments concepts: A case study for intra-aortic balloon pumping.

    PubMed

    Chang, Ching-I; Yan, Huey-Yeu; Sung, Wen-Hsu; Shen, Shu-Cheng; Chuang, Pao-Yu

    2006-01-01

    The purpose of this research was to develop a computer-aided instruction system for intra-aortic balloon pumping (IABP) skills in clinical nursing with virtual instrument (VI) concepts. Computer graphic technologies were incorporated to provide not only static clinical nursing education, but also the simulated function of operating an expensive medical instrument with VI techniques. The content of nursing knowledge was adapted from current well-accepted clinical training materials. The VI functions were developed using computer graphic technology with photos of real medical instruments taken by digital camera. We wish the system could provide beginners of nursing education important teaching assistance.

  16. A LabVIEW-Based Virtual Instrument System for Laser-Induced Fluorescence Spectroscopy.

    PubMed

    Wu, Qijun; Wang, Lufei; Zu, Lily

    2011-01-01

    We report the design and operation of a Virtual Instrument (VI) system based on LabVIEW 2009 for laser-induced fluorescence experiments. This system achieves synchronous control of equipment and acquisition of real-time fluorescence data communicating with a single computer via GPIB, USB, RS232, and parallel ports. The reported VI system can also accomplish data display, saving, and analysis, and printing the results. The VI system performs sequences of operations automatically, and this system has been successfully applied to obtain the excitation and dispersion spectra of α-methylnaphthalene. The reported VI system opens up new possibilities for researchers and increases the efficiency and precision of experiments. The design and operation of the VI system are described in detail in this paper, and the advantages that this system can provide are highlighted.

  17. A LabVIEW-Based Virtual Instrument System for Laser-Induced Fluorescence Spectroscopy

    PubMed Central

    Wu, Qijun; Wang, Lufei; Zu, Lily

    2011-01-01

    We report the design and operation of a Virtual Instrument (VI) system based on LabVIEW 2009 for laser-induced fluorescence experiments. This system achieves synchronous control of equipment and acquisition of real-time fluorescence data communicating with a single computer via GPIB, USB, RS232, and parallel ports. The reported VI system can also accomplish data display, saving, and analysis, and printing the results. The VI system performs sequences of operations automatically, and this system has been successfully applied to obtain the excitation and dispersion spectra of α-methylnaphthalene. The reported VI system opens up new possibilities for researchers and increases the efficiency and precision of experiments. The design and operation of the VI system are described in detail in this paper, and the advantages that this system can provide are highlighted. PMID:22013388

  18. 21 CFR 888.4540 - Orthopedic manual surgical instrument.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ..., femoral neck punch, socket pusher, reamer, rongeur, scissors, screwdriver, bone skid, staple driver, bone screw starter, surgical stripper, tamp, bone tap, trephine, wire twister, and wrench. (b) Classification...

  19. 21 CFR 888.4540 - Orthopedic manual surgical instrument.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ..., femoral neck punch, socket pusher, reamer, rongeur, scissors, screwdriver, bone skid, staple driver, bone screw starter, surgical stripper, tamp, bone tap, trephine, wire twister, and wrench. (b) Classification...

  20. 21 CFR 888.4540 - Orthopedic manual surgical instrument.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ..., femoral neck punch, socket pusher, reamer, rongeur, scissors, screwdriver, bone skid, staple driver, bone screw starter, surgical stripper, tamp, bone tap, trephine, wire twister, and wrench. (b) Classification...

  1. 21 CFR 888.4540 - Orthopedic manual surgical instrument.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ..., femoral neck punch, socket pusher, reamer, rongeur, scissors, screwdriver, bone skid, staple driver, bone screw starter, surgical stripper, tamp, bone tap, trephine, wire twister, and wrench. (b) Classification...

  2. 21 CFR 888.4540 - Orthopedic manual surgical instrument.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ..., femoral neck punch, socket pusher, reamer, rongeur, scissors, screwdriver, bone skid, staple driver, bone screw starter, surgical stripper, tamp, bone tap, trephine, wire twister, and wrench. (b) Classification...

  3. A study on factors of dissatisfaction and stress of the blacksmiths resulting from the organizational culture in the surgical instrument industry of India

    PubMed Central

    Ghosh, Tirthankar; Das, Banibrata; Gangopadhyay, Somnath

    2011-01-01

    Background: It is important to understand what motivates workers and the extent to which the organization and other contextual variables satisfy them. The aim of the study was to determine factors of dissatisfaction resulting from the organizational culture among the blacksmiths involved in the surgical instrument industry. Materials and Methods: Fifty male surgical blacksmiths each of the skilled and unskilled groups of the forging section were selected. Organizational Role Stress Scale was used to measure the individuals’ role stress and several forms of conflict within an organization. Also, the organizational culture and personal involvement in an organization was measured among the surgical blacksmiths. Results: The mean score for total role stress for Skilled was 71.7 and for unskilled was 77.2. The most frequent type of organizational culture was reported to be hierarchy, both by skilled and unskilled surgical blacksmiths, followed by market and clan culture. Conclusion: This study shows that the skilled surgical blacksmiths have lower level of stress and conflicts in comparison with unskilled surgical blacksmiths. Both skilled and unskilled surgical blacksmiths estimated their level of personal involvement as low and indicated insufficient involvement in work teams. The satisfaction of the employees with their status and role in the organizational culture was also poor for both skilled and unskilled surgical blacksmiths. PMID:23271868

  4. KENO-VI Primer: A Primer for Criticality Calculations with SCALE/KENO-VI Using GeeWiz

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bowman, Stephen M

    2008-09-01

    The SCALE (Standardized Computer Analyses for Licensing Evaluation) computer software system developed at Oak Ridge National Laboratory is widely used and accepted around the world for criticality safety analyses. The well-known KENO-VI three-dimensional Monte Carlo criticality computer code is one of the primary criticality safety analysis tools in SCALE. The KENO-VI primer is designed to help a new user understand and use the SCALE/KENO-VI Monte Carlo code for nuclear criticality safety analyses. It assumes that the user has a college education in a technical field. There is no assumption of familiarity with Monte Carlo codes in general or with SCALE/KENO-VImore » in particular. The primer is designed to teach by example, with each example illustrating two or three features of SCALE/KENO-VI that are useful in criticality analyses. The primer is based on SCALE 6, which includes the Graphically Enhanced Editing Wizard (GeeWiz) Windows user interface. Each example uses GeeWiz to provide the framework for preparing input data and viewing output results. Starting with a Quickstart section, the primer gives an overview of the basic requirements for SCALE/KENO-VI input and allows the user to quickly run a simple criticality problem with SCALE/KENO-VI. The sections that follow Quickstart include a list of basic objectives at the beginning that identifies the goal of the section and the individual SCALE/KENO-VI features that are covered in detail in the sample problems in that section. Upon completion of the primer, a new user should be comfortable using GeeWiz to set up criticality problems in SCALE/KENO-VI. The primer provides a starting point for the criticality safety analyst who uses SCALE/KENO-VI. Complete descriptions are provided in the SCALE/KENO-VI manual. Although the primer is self-contained, it is intended as a companion volume to the SCALE/KENO-VI documentation. (The SCALE manual is provided on the SCALE installation DVD.) The primer provides specific

  5. Creation and validation of the self-efficacy instrument for physical education teacher education majors toward inclusion.

    PubMed

    Block, Martin E; Hutzler, Yeshayahu; Barak, Sharon; Klavina, Aija

    2013-04-01

    The purpose was to validate a self-efficacy (SE) instrument toward including students with disability in physical education (PE). Three scales referring to intellectual disabilities (ID), physical disabilities (PD), or visual impairments (VI) were administered to 486 physical education teacher education (PETE) majors. The sample was randomly split, and exploratory and confirmatory factor analyses (EFA and CFA, respectively) were conducted. After deleting items that did not meet inclusion criteria, EFA item loadings ranged from 0.53 to 0.91, and Cronbach's alpha reliability was high (for ID = .86, PD = .90, and VI = .92). CFA showed that the ID scale demonstrated good goodness-of-fit, whereas in the PD and in the VI scales demonstrated moderate fit. Thus, the content and construct validity of the instrument was supported.

  6. Shortened OR time and decreased patient risk through use of a modular surgical instrument with artificial intelligence.

    PubMed

    Miller, David J; Nelson, Carl A; Oleynikov, Dmitry

    2009-05-01

    With a limited number of access ports, minimally invasive surgery (MIS) often requires the complete removal of one tool and reinsertion of another. Modular or multifunctional tools can be used to avoid this step. In this study, soft computing techniques are used to optimally arrange a modular tool's functional tips, allowing surgeons to deliver treatment of improved quality in less time, decreasing overall cost. The investigators watched University Medical Center surgeons perform MIS procedures (e.g., cholecystectomy and Nissen fundoplication) and recorded the procedures to digital video. The video was then used to analyze the types of instruments used, the duration of each use, and the function of each instrument. These data were aggregated with fuzzy logic techniques using four membership functions to quantify the overall usefulness of each tool. This allowed subsequent optimization of the arrangement of functional tips within the modular tool to decrease overall time spent changing instruments during simulated surgical procedures based on the video recordings. Based on a prototype and a virtual model of a multifunction laparoscopic tool designed by the investigators that can interchange six different instrument tips through the tool's shaft, the range of tool change times is approximately 11-13 s. Using this figure, estimated time savings for the procedures analyzed ranged from 2.5 to over 32 min, and on average, total surgery time can be reduced by almost 17% by using the multifunction tool.

  7. Study on virtual instrument developing system based on intelligent virtual control

    NASA Astrophysics Data System (ADS)

    Tang, Baoping; Cheng, Fabin; Qin, Shuren

    2005-01-01

    The paper introduces a non-programming developing system of a virtual instument (VI), i.e., a virtual measurement instrument developing system (VMIDS) based on intelligent virtual control (IVC). The background of the IVC-based VMIDS is described briefly, and the hierarchical message bus (HMB)-based software architecture of VMIDS is discussed in detail. The three parts and functions of VMIDS are introduced, and the process of non-programming developing VI is further described.

  8. Observations on a set of Greco-Roman eye, ear, nose, and throat surgical instruments.

    PubMed

    Dedo, Herbert H

    2017-02-01

    The tools described in this article are verified to be Greco-Roman medical and surgical instruments for the eye, ear, nose, and throat. They include three myrtle leaf-shaped scalpels, three ear spoons, a "Q-tip," a forceps, a needle, and two arrow-pointed scalpels. One of the arrow-pointed scalpels is nearly identical to a Juerger keratome, suggesting that in Roman times, cataracts were extracted, not just "couched" into the posterior chamber. The description presented here goes beyond traditional archeological claims, because as a head and neck surgeon, I evaluated these instruments from a surgeon's point of view. For example, nonsurgeon medical historians have claimed the myrtle leaf-shaped items were used as handles or for blunt dissection, which I feel is mistaken. Review of the literature reveals the Greco-Roman surgeons were doing tonsillectomies, tracheotomies, and cataract extractions, and recognized that swimming in dirty water could cause ear infection. However, it is clear that with poor or no anesthesia, the pain from blunt dissection would have been intolerable, and unnecessary tissue planes would have been opened increasing wound infection risks. Therefore, there would have been no need for the myrtle leaf-shaped blade if it were just a handle. Laryngoscope, 2016 127:354-358, 2017. © 2016 The American Laryngological, Rhinological and Otological Society, Inc.

  9. 29 CFR 1926.1126 - Chromium (VI).

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... activity involving chromium cannot release dusts, fumes, or mists of chromium (VI) in concentrations at or... 29 Labor 8 2014-07-01 2014-07-01 false Chromium (VI). 1926.1126 Section 1926.1126 Labor... Chromium (VI). (a) Scope. (1) This standard applies to occupational exposures to chromium (VI) in all forms...

  10. 29 CFR 1926.1126 - Chromium (VI).

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... activity involving chromium cannot release dusts, fumes, or mists of chromium (VI) in concentrations at or... 29 Labor 8 2012-07-01 2012-07-01 false Chromium (VI). 1926.1126 Section 1926.1126 Labor... Chromium (VI). (a) Scope. (1) This standard applies to occupational exposures to chromium (VI) in all forms...

  11. 29 CFR 1926.1126 - Chromium (VI).

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... activity involving chromium cannot release dusts, fumes, or mists of chromium (VI) in concentrations at or... 29 Labor 8 2011-07-01 2011-07-01 false Chromium (VI). 1926.1126 Section 1926.1126 Labor... Chromium (VI). (a) Scope. (1) This standard applies to occupational exposures to chromium (VI) in all forms...

  12. 29 CFR 1926.1126 - Chromium (VI).

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... activity involving chromium cannot release dusts, fumes, or mists of chromium (VI) in concentrations at or... 29 Labor 8 2013-07-01 2013-07-01 false Chromium (VI). 1926.1126 Section 1926.1126 Labor... Chromium (VI). (a) Scope. (1) This standard applies to occupational exposures to chromium (VI) in all forms...

  13. Computation and visualization of uncertainty in surgical navigation.

    PubMed

    Simpson, Amber L; Ma, Burton; Vasarhelyi, Edward M; Borschneck, Dan P; Ellis, Randy E; James Stewart, A

    2014-09-01

    Surgical displays do not show uncertainty information with respect to the position and orientation of instruments. Data is presented as though it were perfect; surgeons unaware of this uncertainty could make critical navigational mistakes. The propagation of uncertainty to the tip of a surgical instrument is described and a novel uncertainty visualization method is proposed. An extensive study with surgeons has examined the effect of uncertainty visualization on surgical performance with pedicle screw insertion, a procedure highly sensitive to uncertain data. It is shown that surgical performance (time to insert screw, degree of breach of pedicle, and rotation error) is not impeded by the additional cognitive burden imposed by uncertainty visualization. Uncertainty can be computed in real time and visualized without adversely affecting surgical performance, and the best method of uncertainty visualization may depend upon the type of navigation display. Copyright © 2013 John Wiley & Sons, Ltd.

  14. Development and application of network virtual instrument for emission spectrum of pulsed high-voltage direct current discharge

    NASA Astrophysics Data System (ADS)

    Gong, X.; Wu, Q.

    2017-12-01

    Network virtual instrument (VI) is a new development direction in current automated test. Based on LabVIEW, the software and hardware system of VI used for emission spectrum of pulsed high-voltage direct current (DC) discharge is developed and applied to investigate pulsed high-voltage DC discharge of nitrogen. By doing so, various functions are realized including real time collection of emission spectrum of nitrogen, monitoring operation state of instruments and real time analysis and processing of data. By using shared variables and DataSocket technology in LabVIEW, the network VI system based on field VI is established. The system can acquire the emission spectrum of nitrogen in the test site, monitor operation states of field instruments, realize real time face-to-face interchange of two sites, and analyze data in the far-end from the network terminal. By employing the network VI system, the staff in the two sites acquired the same emission spectrum of nitrogen and conducted the real time communication. By comparing with the previous results, it can be seen that the experimental data obtained by using the system are highly precise. This implies that the system shows reliable network stability and safety and satisfies the requirements for studying the emission spectrum of pulsed high-voltage discharge in high-precision fields or network terminals. The proposed architecture system is described and the target group gets the useful enlightenment in many fields including engineering remote users, specifically in control- and automation-related tasks.

  15. Diverse anaerobic Cr(VI) tolerant bacteria from Cr(VI)-contaminated 100H site at Hanford

    NASA Astrophysics Data System (ADS)

    Chakraborty, R.; Phan, R.; Lam, S.; Leung, C.; Brodie, E. L.; Hazen, T. C.

    2007-12-01

    Hexavalent Chromium [Cr(VI)] is a widespread contaminant found in soil, sediment, and ground water. Cr(VI) is more soluble, toxic, carcinogenic, and mutagenic compared to its reduced form Cr(III). In order to stimulate microbially mediated reduction of Cr(VI), a poly-lactate compound HRC was injected into the chromium contaminated aquifers at site 100H at Hanford. Based on the results of the bacterial community composition using high-density DNA microarray analysis of 16S rRNA gene products, we recently investigated the diversity of the dominant anaerobic culturable microbial population present at this site and their role in Cr(VI) reduction. Positive enrichments set up at 30°C using specific defined anaerobic media resulted in the isolation of an iron reducing isolate strain HAF, a sulfate reducing isolate strain HBLS and a nitrate reducing isolate, strain HLN among several others. Preliminary 16S rDNA sequence analysis identifies strain HAF as Geobacter metallireducens, strain HLN as Pseudomonas stutzeri and strain HBLS as a member of Desulfovibrio species. Strain HAF isolated with acetate as the electron donor utilized propionate, glycerol and pyruvate as alternative carbon sources, and reduced metals like Mn(IV) and Cr(VI). Growth was optimal at 37°C, pH of 6.5 and 0% salinity. Strain HLN isolated with lactate as electron donor utilized acetate, glycerol and pyruvate as alternative carbon sources, and reduced metals like Mn(IV) and Cr(VI). Optimal growth was observed at 37°C, at a pH of 7.5 and 0.3% salinity. Anaerobic active washed cell suspension of strain HLN reduced almost 95 micromolar Cr(VI) within 4 hours relative to controls. Further, with 100 micromolar Cr(VI) as the sole electron acceptor, cells of strain HLN grew to cell numbers of 4.05X 107/ml over a period of 24hrs after an initial lag, demonstrating direct enzymatic Cr(VI) reduction by this species. 10mM lactate served as the sole electron donor. These results demonstrate that Cr(VI

  16. Impact of Lean on surgical instrument reduction: Less is more.

    PubMed

    Wannemuehler, Todd J; Elghouche, Alhasan N; Kokoska, Mimi S; Deig, Christopher R; Matt, Bruce H

    2015-12-01

    To determine whether instrument sets that are frequently used by multiple surgeons can be substantially reduced in size with consensus. Prospective quality improvement study using Lean Six Sigma for purposeful and consensual reduction of non-value-added instruments in adenotonsillectomy instrument sets. Value stream mapping was utilized to determine instrumentation usage and reprocessing workflow. Preintervention instrument utilization surveys allowed consensual and intelligent set reduction. Non-value-added instruments were targeted for waste elimination by placement in a supplemental set. Times for pre- and postintervention instrument assembly, Mayo setup, and surgery were collected for adenotonsillectomies. Postintervention satisfaction surveys of surgeons and staff were conducted. Adenotonsillectomy sets were reduced from 52 to 24 instruments. Median assembly times were significantly reduced from 8.4 to 4.7 minutes (P < .0001) with a set assembly cost reduction of 44%. Following natural log transformations, mean Mayo setup times were significantly reduced from 97.6 to 76.1 seconds (P < .0001), and mean operative times were not significantly affected (1,773 vs. 1,631 seconds, P > .05). The supplemental set was opened in only 3.6% of cases. Satisfaction was >90% regarding the intervention. Set build cost was reduced by $1,468.99 per set. Lean Six Sigma improves efficiency and reduces waste by empowering team members to improve their environment. Instrument set reduction is ideal for waste elimination because of tool accumulation over time and instrument obsolescence as newer technologies are adopted. Similar interventions could easily be applied to larger sinus, mastoidectomy, and spine sets. NA. © 2015 The American Laryngological, Rhinological and Otological Society, Inc.

  17. Recognition of surgical skills using hidden Markov models

    NASA Astrophysics Data System (ADS)

    Speidel, Stefanie; Zentek, Tom; Sudra, Gunther; Gehrig, Tobias; Müller-Stich, Beat Peter; Gutt, Carsten; Dillmann, Rüdiger

    2009-02-01

    Minimally invasive surgery is a highly complex medical discipline and can be regarded as a major breakthrough in surgical technique. A minimally invasive intervention requires enhanced motor skills to deal with difficulties like the complex hand-eye coordination and restricted mobility. To alleviate these constraints we propose to enhance the surgeon's capabilities by providing a context-aware assistance using augmented reality techniques. To recognize and analyze the current situation for context-aware assistance, we need intraoperative sensor data and a model of the intervention. Characteristics of a situation are the performed activity, the used instruments, the surgical objects and the anatomical structures. Important information about the surgical activity can be acquired by recognizing the surgical gesture performed. Surgical gestures in minimally invasive surgery like cutting, knot-tying or suturing are here referred to as surgical skills. We use the motion data from the endoscopic instruments to classify and analyze the performed skill and even use it for skill evaluation in a training scenario. The system uses Hidden Markov Models (HMM) to model and recognize a specific surgical skill like knot-tying or suturing with an average recognition rate of 92%.

  18. [Evaluation of Medical Instruments Cleaning Effect of Fluorescence Detection Technique].

    PubMed

    Sheng, Nan; Shen, Yue; Li, Zhen; Li, Huijuan; Zhou, Chaoqun

    2016-01-01

    To compare the cleaning effect of automatic cleaning machine and manual cleaning on coupling type surgical instruments. A total of 32 cleaned medical instruments were randomly sampled from medical institutions in Putuo District medical institutions disinfection supply center. Hygiena System SUREII ATP was used to monitor the ATP value, and the cleaning effect was evaluated. The surface ATP values of the medical instrument of manual cleaning were higher than that of the automatic cleaning machine. Coupling type surgical instruments has better cleaning effect of automatic cleaning machine before disinfection, the application is recommended.

  19. 21 CFR 872.4535 - Dental diamond instrument.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Dental diamond instrument. 872.4535 Section 872...) MEDICAL DEVICES DENTAL DEVICES Surgical Devices § 872.4535 Dental diamond instrument. (a) Identification. A dental diamond instrument is an abrasive device intended to smooth tooth surfaces during the...

  20. 21 CFR 872.4535 - Dental diamond instrument.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Dental diamond instrument. 872.4535 Section 872...) MEDICAL DEVICES DENTAL DEVICES Surgical Devices § 872.4535 Dental diamond instrument. (a) Identification. A dental diamond instrument is an abrasive device intended to smooth tooth surfaces during the...

  1. 21 CFR 872.4535 - Dental diamond instrument.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Dental diamond instrument. 872.4535 Section 872...) MEDICAL DEVICES DENTAL DEVICES Surgical Devices § 872.4535 Dental diamond instrument. (a) Identification. A dental diamond instrument is an abrasive device intended to smooth tooth surfaces during the...

  2. 21 CFR 872.4535 - Dental diamond instrument.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Dental diamond instrument. 872.4535 Section 872...) MEDICAL DEVICES DENTAL DEVICES Surgical Devices § 872.4535 Dental diamond instrument. (a) Identification. A dental diamond instrument is an abrasive device intended to smooth tooth surfaces during the...

  3. 21 CFR 872.4535 - Dental diamond instrument.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Dental diamond instrument. 872.4535 Section 872...) MEDICAL DEVICES DENTAL DEVICES Surgical Devices § 872.4535 Dental diamond instrument. (a) Identification. A dental diamond instrument is an abrasive device intended to smooth tooth surfaces during the...

  4. Surgical robot for single-incision laparoscopic surgery.

    PubMed

    Choi, Hyundo; Kwak, Ho-Seong; Lim, Yo-An; Kim, Hyung-Joo

    2014-09-01

    This paper introduces a novel surgical robot for single-incision laparoscopic surgeries. The robot system includes the cone-type remote center-of-motion (RCM) mechanism and two articulated instruments having a flexible linkage-driven elbow. The RCM mechanism, which has two revolute joints and one prismatic joint, is designed to maintain a stationary point at the apex of the cone shape. By placing the stationary point on the incision area, the mechanism allows a surgical instrument to explore the abdominal area through a small incision point. The instruments have six articulated joints, including an elbow pitch joint, which make the triangulation position for the surgery possible inside of the abdominal area. The presented elbow pitch structure is similar to the slider-crank mechanism but the connecting rod is composed of a flexible leaf spring for high payload and small looseness error. We verified the payload of the robot is more than 10 N and described preliminary experiments on peg transfer and suture motion by using the proposed surgical robot.

  5. Effect of drying time, ambient temperature and pre-soaks on prion-infected tissue contamination levels on surgical stainless steel: concerns over prolonged transportation of instruments from theatre to central sterile service departments.

    PubMed

    Lipscomb, I P; Pinchin, H; Collin, R; Keevil, C W

    2007-01-01

    Iatrogenic transmission of prions through use of surgical instruments has been shown both experimentally and clinically. In addition, recent discoveries of prion protein accumulation in peripheral tissues such as appendix and muscle, and evidence suggesting human-to-human blood-borne transmission, have led to a concern that any residual soiling containing this agent may remain infectious even after sterile service processing. Removal of all proteinaceous material from surgical devices is extremely important for effective sterilization. This removal can be severely hampered if the contaminant is allowed to dry onto the instrument surface for any length of time. The current move to centralize sterile service centres and the inevitable lengthening of transport time between theatres and re-processing makes it necessary to minimize the amount of residual soiling adhering to an instrument before sterilization. This investigation simulates the period between the application of surgical instruments in theatre and their initial pre-wash by a washer/disinfector. The aim was to investigate the kinetics of drying at different temperatures, and the application of different commercially available pre-soak solutions in situ. The findings show that all pre-soaks significantly reduce (by up to 96%) the prion-infected tissue contamination, and that controlling the temperature whilst in transit between theatres and cleaning facilities may allow an increase in time before high protein adsorption levels occur.

  6. 21 CFR 882.4275 - Dowel cutting instrument.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Dowel cutting instrument. 882.4275 Section 882...) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4275 Dowel cutting instrument. (a) Identification. A dowel cutting instrument is a device used to cut dowels of bone for bone grafting. (b...

  7. Navigated Breast Tumor Excision Using Electromagnetically Tracked Ultrasound and Surgical Instruments.

    PubMed

    Ungi, Tamas; Gauvin, Gabrielle; Lasso, Andras; Yeo, Caitlin T; Pezeshki, Padina; Vaughan, Thomas; Carter, Kaci; Rudan, John; Engel, C Jay; Fichtinger, Gabor

    2016-03-01

    Lumpectomy, breast conserving tumor excision, is the standard surgical treatment in early stage breast cancer. A common problem with lumpectomy is that the tumor may not be completely excised, and additional surgery becomes necessary. We investigated if a surgical navigation system using intraoperative ultrasound improves the outcomes of lumpectomy and if such a system can be implemented in the clinical environment. Position sensors were applied on the tumor localization needle, the ultrasound probe, and the cautery, and 3-D navigation views were generated using real-time tracking information. The system was tested against standard wire-localization procedures on phantom breast models by eight surgical residents. Clinical safety and feasibility was tested in six palpable tumor patients undergoing lumpectomy by two experienced surgical oncologists. Navigation resulted in significantly less tissue excised compared to control procedures (10.3 ± 4.4 versus 18.6 ± 8.7 g, p = 0.01) and lower number of tumor-positive margins (1/8 versus 4/8) in the phantom experiments. Excision-tumor distance was also more consistently outside the tumor margins with navigation in phantoms. The navigation system has been successfully integrated in an operating room, and user experience was rated positively by surgical oncologists. Electromagnetic navigation may improve the outcomes of lumpectomy by making the tumor excision more accurate. Breast cancer is the most common cancer in women, and lumpectomy is its first choice treatment. Therefore, the improvement of lumpectomy outcomes has a significant impact on a large patient population.

  8. Ferrate(VI) oxidation of zinc-cyanide complex.

    PubMed

    Yngard, Ria; Damrongsiri, Seelawut; Osathaphan, Khemarath; Sharma, Virender K

    2007-10-01

    Zinc-cyanide complexes are found in gold mining effluents and in metal finishing rinse water. The effect of Zn(II) on the oxidation of cyanide by ferrate(VI) (Fe(VI)O(4)(2-), Fe(VI)) was thus investigated by studying the kinetics of the reaction of Fe(VI) with cyanide present in a potassium salt of a zinc cyanide complex (K(2)Zn(CN)(4)) and in a mixture of Zn(II) and cyanide solutions as a function of pH (9.0-11.0). The rate-law for the oxidation of Zn(CN)(4)(2-) by Fe(VI) was found to be -d[Fe(VI)]/dt=k[Fe(VI)][Zn(CN)(4)(2-)](0.5). The rate constant, k, decreased with an increase in pH. The effect of temperature (15-45 degrees C) on the oxidation was studied at pH 9.0, which gave an activation energy of 45.7+/-1.5kJmol(-1). The cyanide oxidation rate decreased in the presence of the Zn(II) ions. However, Zn(II) ions had no effect on the cyanide removal efficiency by Fe(VI) and the stoichiometry of Fe(VI) to cyanide was approximately 1:1; similar to the stoichiometry in absence of Zn(II) ions. The destruction of cyanide by Fe(VI) resulted in cyanate. The experiments on removal of cyanide from rinse water using Fe(VI) demonstrated complete conversion of cyanide to cyanate.

  9. IV-VI semiconductor lasers for gas phase biomarker detection

    NASA Astrophysics Data System (ADS)

    McCann, Patrick; Namjou, Khosrow; Roller, Chad; McMillen, Gina; Kamat, Pratyuma

    2007-09-01

    A promising absorption spectroscopy application for mid-IR lasers is exhaled breath analysis where sensitive, selective, and speedy measurement of small gas phase biomarker molecules can be used to diagnose disease and monitor therapies. Many molecules such as nitric oxide, ethane, formaldehyde, acetaldehyde, acetone, carbonyl sulfide, and carbon disulfide have been connected to diseases or conditions such as asthma, oxidative stress, breast cancer, lung cancer, diabetes, organ transplant rejection, and schizophrenia. Measuring these and other, yet to be discovered, biomarker molecules in exhaled breath with mid-IR lasers offers great potential for improving health care since such tests are non-invasive, real-time, and do not require expensive consumables or chemical reagents. Motivated by these potential benefits, mid-IR laser spectrometers equipped with presently available cryogenically-cooled IV-VI lasers mounted in compact Stirling coolers have been developed for clinical research applications. This paper will begin with a description of the development of mid-IR laser instruments and their use in the largest known exhaled breath clinical study ever performed. It will then shift to a description of recent work on the development of new IV-VI semiconductor quantum well materials and laser fabrication methods that offer the promise of low power consumption (i.e. efficient) continuous wave emission at room temperature. Taken together, the demonstration of compelling clinical applications with large market opportunities and the clear identification of a viable pathway to develop low cost mid-IR laser instrumentation can create a renewed focus for future research and development efforts within the mid-IR materials and devices area.

  10. 76 FR 60593 - Title VI; Proposed Circular

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-29

    ... DEPARTMENT OF TRANSPORTATION Federal Transit Administration [Docket No. FTA-2011-0054] Title VI... complying with Title VI of the Civil Rights Act of 1964. The purpose of this Circular is to provide.... Department of Transportation's Title VI regulations (49 CFR part 21). FTA is updating its Title VI Circular...

  11. The Development of an Electronic Portfolio for Postgraduate Surgical Training in Flanders.

    PubMed

    Peeraer, G; Van Humbeeck, B; De Leyn, P; Delvaux, G; Hubens, G; Pattyn, P; De Win, G

    2015-01-01

    Contemporary surgical postgraduate training is characterized by clear outcomes for the profession and an assessment program that shows that trainees master these outcomes. The tool used to collect assessment and feedback instruments is the portfolio, nowadays used in many countries worldwide. The four Flemish surgical coordinators, together with experts from different universities, devised an electronic portfolio. This portfolio holds both the logbook, as imposed by the evaluation committee and assessment instruments used for the Master in Specialized Medicine. The e-portfolio is now used by a number of surgical trainees and has been approved by the evaluation committee. In 1015, all Flemish surgical trainees will be using one and the same e-portfolio. Although the e-portfolio for surgical training has now been devised and accepted by all major parties involved, a lot of work has to be done to implement the instrument. As resident duty hours show no improvement on education in surgery (but rather a perception of worsened education) surgery training is fazing huge challenges.

  12. 21 CFR 872.4565 - Dental hand instrument.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Dental hand instrument. 872.4565 Section 872.4565...) MEDICAL DEVICES DENTAL DEVICES Surgical Devices § 872.4565 Dental hand instrument. (a) Identification. A dental hand instrument is a hand-held device intended to perform various tasks in general dentistry and...

  13. 21 CFR 872.4565 - Dental hand instrument.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Dental hand instrument. 872.4565 Section 872.4565...) MEDICAL DEVICES DENTAL DEVICES Surgical Devices § 872.4565 Dental hand instrument. (a) Identification. A dental hand instrument is a hand-held device intended to perform various tasks in general dentistry and...

  14. 21 CFR 872.4565 - Dental hand instrument.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Dental hand instrument. 872.4565 Section 872.4565...) MEDICAL DEVICES DENTAL DEVICES Surgical Devices § 872.4565 Dental hand instrument. (a) Identification. A dental hand instrument is a hand-held device intended to perform various tasks in general dentistry and...

  15. 21 CFR 872.4565 - Dental hand instrument.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Dental hand instrument. 872.4565 Section 872.4565...) MEDICAL DEVICES DENTAL DEVICES Surgical Devices § 872.4565 Dental hand instrument. (a) Identification. A dental hand instrument is a hand-held device intended to perform various tasks in general dentistry and...

  16. 21 CFR 872.4565 - Dental hand instrument.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Dental hand instrument. 872.4565 Section 872.4565...) MEDICAL DEVICES DENTAL DEVICES Surgical Devices § 872.4565 Dental hand instrument. (a) Identification. A dental hand instrument is a hand-held device intended to perform various tasks in general dentistry and...

  17. 21 CFR 888.5960 - Cast removal instrument.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Cast removal instrument. 888.5960 Section 888.5960...) MEDICAL DEVICES ORTHOPEDIC DEVICES Surgical Devices § 888.5960 Cast removal instrument. (a) Identification. A cast removal instrument is an AC-powered, hand-held device intended to remove a cast from a...

  18. Improving Operating Room Efficiency via Reduction and Standardization of Video-Assisted Thoracoscopic Surgery Instrumentation.

    PubMed

    Friend, Tynan H; Paula, Ashley; Klemm, Jason; Rosa, Mark; Levine, Wilton

    2018-05-28

    Being the economic powerhouses of most large medical centers, operating rooms (ORs) require the highest levels of teamwork, communication, and efficiency in order to optimize patient safety and reduce hospital waste. A major component of OR waste comes from unused surgical instrumentation; instruments that are frequently prepared for procedures but are never touched by the surgical team still require a full reprocessing cycle at the conclusion of the case. Based on our own previous successes in the perioperative domain, in this work we detail an initiative that reduces surgical instrumentation waste of video-assisted thoracoscopic surgery (VATS) procedures by placing thoracotomy conversion instrumentation in a standby location and designing a specific instrument kit to be used solely for VATS cases. Our estimates suggest that this initiative will reduce at least 91,800 pounds of unnecessary surgical instrumentation from cycling through our ORs and reprocessing department annually, resulting in increased OR team communication without sacrificing the highest standard of patient safety.

  19. Pneumatic-type surgical robot end-effector for laparoscopic surgical-operation-by-wire.

    PubMed

    Lee, Chiwon; Park, Woo Jung; Kim, Myungjoon; Noh, Seungwoo; Yoon, Chiyul; Lee, Choonghee; Kim, Youdan; Kim, Hyeon Hoe; Kim, Hee Chan; Kim, Sungwan

    2014-09-05

    Although minimally invasive surgery (MIS) affords several advantages compared to conventional open surgery, robotic MIS systems still have many limitations. One of the limitations is the non-uniform gripping force due to mechanical strings of the existing systems. To overcome this limitation, a surgical instrument with a pneumatic gripping system consisting of a compressor, catheter balloon, micro motor, and other parts is developed. This study aims to implement a surgical instrument with a pneumatic gripping system and pitching/yawing joints using micro motors and without mechanical strings based on the surgical-operation-by-wire (SOBW) concept. A 6-axis external arm for increasing degrees of freedom (DOFs) is integrated with the surgical instrument using LabVIEW® for laparoscopic procedures. The gripping force is measured over a wide range of pressures and compared with the simulated ideal step function. Furthermore, a kinematic analysis is conducted. To validate and evaluate the system's clinical applicability, a simple peg task experiment and workspace identification experiment are performed with five novice volunteers using the fundamentals of laparoscopic surgery (FLS) board kit. The master interface of the proposed system employs the hands-on-throttle-and-stick (HOTAS) controller used in aerospace engineering. To develop an improved HOTAS (iHOTAS) controller, 6-axis force/torque sensor was integrated in the special housing. The mean gripping force (after 1,000 repetitions) at a pressure of 0.3 MPa was measured to be 5.8 N. The reaction time was found to be 0.4 s, which is almost real-time. All novice volunteers could complete the simple peg task within a mean time of 176 s, and none of them exceeded the 300 s cut-off time. The system's workspace was calculated to be 11,157.0 cm3. The proposed pneumatic gripping system provides a force consistent with that of other robotic MIS systems. It provides near real-time control. It is more durable than the

  20. Surgical Lasers In Gynecology

    NASA Astrophysics Data System (ADS)

    Schellhas, Helmut F.; Barnes, Alfonso E.

    1982-12-01

    Multipurpose surgical CO2 lasers marketed in the USA have been developed to be applicable to a variety of surgical procedures in many surgical fields. They are all suited for endoscopic surgical procedures and can be fitted to all standard surgical microscopes. They all can adjust the focal length of the laser beam to the different standard focal lengths of the surgical microscope which for instance in laryngoscopy is 400 mm and in colposcopy 300 mm. One laser instrument can even change the spot size in a given focal distance which is very advantageous for some microsurgical procedures (Merrimack Laboratories 820). All multipurpose surgical CO2 laser systems provide a multi-articulated surgical arm for free-hand surgery. The surgical arms are cumbersome to use but they are adapted to the surgeons needs with ingenuity. The practicality of the multi-articulated surgical arms depends mostly on the distance of the handpiece from the surgical console which now is also overbridged by the laser tube in most surgical laser system. The spot size of the beam is variable in most handpieces by interchangeable lenses which modify the focal distance of the beam and the power density. Another common feature in all systems is a coaxial He-Ne pilot light which provides a red spot which unfortunately becomes invisible in a bleeding surgical field. Most surgical laser systems have a spacial mode of TEM 00 which is essential for incisional surgery. The continuous mode of beam delivery is used for incisional surgery and also for most endoscopic procedures.

  1. Teaching Surgical Hysteroscopy with a Computer

    PubMed

    Lefebvre; Cote; Lefebvre

    1996-08-01

    Using a hysteroscope can be simulated on a computer. It will improve physician training by measuring basic knowledge and abilities, allow different interventions and anatomic variations, minimize the trauma of surgical intervention, and reduce operative casualties. An integrated questionnaire covers instrumentation, fluid infusion, power source, indications and preparation for endometrial ablation, surgical techniques, and complications to evaluate the user's knowledge. The operation simulation then proceeds. In the endometrial cavity, by virtual simulation, the operating field should appear in real time to allow physicians to adapt the trajectory of the instruments. The computer is an IBM PC compatible. We use a modified joystick with optical encoders to know the instrument position. The simulation can be repeated as desired. An evaluation system is integrated in the software to keep the user informed on the amount of burn area(s) that have been completed. This prototype model is available.

  2. Does the piezoelectric surgical technique produce fewer postoperative sequelae after lower third molar surgery than conventional rotary instruments? A systematic review and meta analysis.

    PubMed

    Al-Moraissi, E A; Elmansi, Y A; Al-Sharaee, Y A; Alrmali, A E; Alkhutari, A S

    2016-03-01

    A systematic review and meta-analysis was conducted to answer the clinical question "Does the piezoelectric surgical technique produce fewer postoperative sequelae after lower third molar surgery than conventional rotary instruments?" A systematic and electronic search of several databases with specific key words, a reference search, and a manual search were performed from respective dates of inception through November 2014. The inclusion criteria were clinical human studies, including randomized controlled trials (RCTs), controlled clinical trials (CCTs), and retrospective studies, with the aim of comparing the piezoelectric surgical osteotomy technique to the standard rotary instrument technique in lower third molar surgery. Postoperative sequelae (oedema, trismus, and pain), the total number of analgesics taken, and the duration of surgery were analyzed. A total of nine articles were included, six RCTs, two CCTs, and one retrospective study. Six studies had a low risk of bias and three had a moderate risk of bias. A statistically significant difference was found between piezoelectric surgery and conventional rotary instrument surgery for lower third molar extraction with regard to postoperative sequelae (oedema, trismus, and pain) and the total number of analgesics taken (P=0.0001, P=0.0001, P<0.00001, and P<0.0001, respectively). However, a statistically significant increased surgery time was required in the piezoelectric osteotomy group (P<0.00001). The results of the meta-analysis showed that piezoelectric surgery significantly reduced the occurrence of postoperative sequelae (oedema, trismus, and pain) and the total number of analgesics taken compared to the conventional rotary instrument technique in lower third molar surgery, but required a longer surgery time. Copyright © 2015 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  3. 21 CFR 882.4560 - Stereotaxic instrument.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Stereotaxic instrument. 882.4560 Section 882.4560 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4560 Stereotaxic instrument. (a...

  4. 21 CFR 882.4560 - Stereotaxic instrument.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Stereotaxic instrument. 882.4560 Section 882.4560 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4560 Stereotaxic instrument. (a...

  5. Reduction of ferrate(VI) and oxidation of cyanate in a Fe(VI)-TiO2-UV-NCO- system.

    PubMed

    Winkelmann, Kurt; Sharma, Virender K; Lin, Yekaterina; Shreve, Katherine A; Winkelmann, Catherine; Hoisington, Laura J; Yngard, Ria A

    2008-08-01

    The aqueous photocatalytic degradation of cyanate (NCO(-)), which is a long-lived neurotoxin formed during the remediation of cyanide in industrial waste streams, was studied in the ferrate(VI)-UV-TiO2-NCO(-) system. Kinetics measurements of the photocatalytic reduction of ferrate(VI) were carried out as a function of [NCO(-)], [ferrate(VI)], [O(2)], light intensity (I(o)), and amount of TiO2 in suspensions at pH 9.0. The photocatalytic reduction rate of ferrate(VI) in the studied system can be expressed as -d[Fe(VI)]/dt=kI(o)(0.5) [NCO(-)] [TiO2]. The rate of photocatalytic oxidation of cyanate with ferrate(VI) was greater than the rate in the analogous system without ferrate(VI). The possibility of involvement of reactive ferrate(V) species for this enhancement was determined by studying the reactivity of ferrate(V) with NCO(-) in a homogeneous solution using a premix pulse radiolysis technique. The rate constant for the reaction of ferrate(V) and NCO(-) in alkaline medium was estimated to be (9.60+/-0.07) x 10(2) M(-1) s(-1), which is much slower than the ferrate(VI) self-decomposition reaction (k approximately 10(7) M(-1) s(-1)). An analysis of the kinetic data in the Fe(VI)-UV-TiO2-NCO(-) system suggests that ferrate(V) is not directly participating in the oxidation of cyanate. Possible reactions in the system are presented to explain results of ferrate(VI) reduction and oxidation of cyanate.

  6. 29 CFR 1915.1026 - Chromium (VI).

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... a specific process, operation, or activity involving chromium cannot release dusts, fumes, or mists... 29 Labor 7 2012-07-01 2012-07-01 false Chromium (VI). 1915.1026 Section 1915.1026 Labor... § 1915.1026 Chromium (VI). (a) Scope. (1) This standard applies to occupational exposures to chromium (VI...

  7. 29 CFR 1915.1026 - Chromium (VI).

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... a specific process, operation, or activity involving chromium cannot release dusts, fumes, or mists... 29 Labor 7 2011-07-01 2011-07-01 false Chromium (VI). 1915.1026 Section 1915.1026 Labor... § 1915.1026 Chromium (VI). (a) Scope. (1) This standard applies to occupational exposures to chromium (VI...

  8. 29 CFR 1915.1026 - Chromium (VI).

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... a specific process, operation, or activity involving chromium cannot release dusts, fumes, or mists... 29 Labor 7 2013-07-01 2013-07-01 false Chromium (VI). 1915.1026 Section 1915.1026 Labor... § 1915.1026 Chromium (VI). (a) Scope. (1) This standard applies to occupational exposures to chromium (VI...

  9. 29 CFR 1915.1026 - Chromium (VI).

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... a specific process, operation, or activity involving chromium cannot release dusts, fumes, or mists... 29 Labor 7 2014-07-01 2014-07-01 false Chromium (VI). 1915.1026 Section 1915.1026 Labor... § 1915.1026 Chromium (VI). (a) Scope. (1) This standard applies to occupational exposures to chromium (VI...

  10. 29 CFR 1926.1126 - Chromium (VI).

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... is present or is likely to be present from skin or eye contact with chromium (VI), the employer shall... cleaned in a manner that minimizes skin or eye contact with chromium (VI) and effectively prevents the... CFR 1926.51 Where skin contact with chromium (VI) occurs, the employer shall provide washing...

  11. Challenging Residual Contamination of Instruments for Robotic Surgery in Japan.

    PubMed

    Saito, Yuhei; Yasuhara, Hiroshi; Murakoshi, Satoshi; Komatsu, Takami; Fukatsu, Kazuhiko; Uetera, Yushi

    2017-02-01

    BACKGROUND Recently, robotic surgery has been introduced in many hospitals. The structure of robotic instruments is so complex that updating their cleaning methods is a challenge for healthcare professionals. However, there is limited information on the effectiveness of cleaning for instruments for robotic surgery. OBJECTIVE To determine the level of residual contamination of instruments for robotic surgery and to develop a method to evaluate the cleaning efficacy for complex surgical devices. METHODS Surgical instruments were collected immediately after operations and/or after in-house cleaning, and the level of residual protein was measured. Three serial measurements were performed on instruments after cleaning to determine the changes in the level of contamination and the total amount of residual protein. The study took place from September 1, 2013, through June 30, 2015, in Japan. RESULTS The amount of protein released from robotic instruments declined exponentially. The amount after in-house cleaning was 650, 550, and 530 µg/instrument in the 3 serial measurements. The overall level of residual protein in each measurement was much higher for robotic instruments than for ordinary instruments (P<.0001). CONCLUSIONS Our data demonstrated that complete removal of residual protein from surgical instruments is virtually impossible. The pattern of decline differed depending on the instrument type, which reflected the complex structure of the instruments. It might be necessary to establish a new standard for cleaning using a novel classification according to the structural complexity of instruments, especially for those for robotic surgery. Infect Control Hosp Epidemiol 2017;38:143-146.

  12. Evaluation of surgical strategy of conventional vs. percutaneous robot-assisted spinal trans-pedicular instrumentation in spondylodiscitis.

    PubMed

    Keric, Naureen; Eum, David J; Afghanyar, Feroz; Rachwal-Czyzewicz, Izabela; Renovanz, Mirjam; Conrad, Jens; Wesp, Dominik M A; Kantelhardt, Sven R; Giese, Alf

    2017-03-01

    Robot-assisted percutaneous insertion of pedicle screws is a recent technique demonstrating high accuracy. The optimal treatment for spondylodiscitis is still a matter of debate. We performed a retrospective cohort study on surgical patients treated with pedicle screw/rod placement alone without the application of intervertebral cages. In this collective, we compare conventional open to a further minimalized percutaneous robot-assisted spinal instrumentation, avoiding a direct contact of implants and infectious focus. 90 records and CT scans of patients treated by dorsal transpedicular instrumentation of the infected segments with and without decompression and antibiotic therapy were analysed for clinical and radiological outcome parameters. 24 patients were treated by free-hand fluoroscopy-guided surgery (121 screws), and 66 patients were treated by percutaneous robot-assisted spinal instrumentation (341 screws). Accurate screw placement was confirmed in 90 % of robot-assisted and 73.5 % of free-hand placed screws. Implant revision due to misplacement was necessary in 4.95 % of the free-hand group compared to 0.58 % in the robot-assisted group. The average intraoperative X-ray exposure per case was 0.94 ± 1.04 min in the free-hand group vs. 0.4 ± 0.16 min in the percutaneous group (p = 0.000). Intraoperative adverse events were observed in 12.5 % of free-hand placed pedicle screws and 6.1 % of robot robot-assisted screws. The mean postoperative hospital stay in the free-hand group was 18.1 ± 12.9 days, and in percutaneous group, 13.8 ± 5.6 days (p = 0.012). This study demonstrates that the robot-guided insertion of pedicle screws is a safe and effective procedure in lumbar and thoracic spondylodiscitis with higher accuracy of implant placement, lower radiation dose, and decreased complication rates. Percutaneous spinal dorsal instrumentation seems to be sufficient to treat lumbar and thoracic spondylodiscitis.

  13. Software design for the VIS instrument onboard the Euclid mission: a multilayer approach

    NASA Astrophysics Data System (ADS)

    Galli, E.; Di Giorgio, A. M.; Pezzuto, S.; Liu, S. J.; Giusi, G.; Li Causi, G.; Farina, M.; Cropper, M.; Denniston, J.; Niemi, S.

    2014-07-01

    The Euclid mission scientific payload is composed of two instruments: a VISible Imaging Instrument (VIS) and a Near Infrared Spectrometer and Photometer instrument (NISP). Each instrument has its own control unit. The Instrument Command and Data Processing Unit (VI-CDPU) is the control unit of the VIS instrument. The VI-CDPU is connected directly to the spacecraft by means of a MIL-STD-1553B bus and to the satellite Mass Memory Unit via a SpaceWire link. All the internal interfaces are implemented via SpaceWire links and include 12 high speed lines for the data provided by the 36 focal plane CCDs readout electronics (ROEs) and one link to the Power and Mechanisms Control Unit (VI-PMCU). VI-CDPU is in charge of distributing commands to the instrument sub-systems, collecting their housekeeping parameters and monitoring their health status. Moreover, the unit has the task of acquiring, reordering, compressing and transferring the science data to the satellite Mass Memory. This last feature is probably the most challenging one for the VI-CDPU, since stringent constraints about the minimum lossless compression ratio, the maximum time for the compression execution and the maximum power consumption have to be satisfied. Therefore, an accurate performance analysis at hardware layer is necessary, which could delay too much the design and development of software. In order to mitigate this risk, in the multilayered design of software we decided to design a middleware layer that provides a set of APIs with the aim of hiding the implementation of the HW connected layer to the application one. The middleware is built on top of the Operating System layer (which includes the Real-Time OS that will be adopted) and the onboard Computer Hardware. The middleware itself has a multi-layer architecture composed of 4 layers: the Abstract RTOS Adapter Layer (AOSAL), the Speci_c RTOS Adapter Layer (SOSAL), the Common Patterns Layer (CPL), the Service Layer composed of two subgroups which

  14. Use of minimally invasive spine surgical instruments for the treatment of bone tumors.

    PubMed

    Reeves, Russell A; DeWolf, Matthew C; Shaughnessy, Peter J; Ames, James B; Henderson, Eric R

    2017-11-01

    Orthopedic oncologists often encounter patients with minor bony lesions that are difficult to access surgically and therefore require large exposures out of proportion to the severity of disease that confer significant patient morbidity. Minimally invasive surgical techniques offer the advantage of smaller incisions, shorter operative times, decreased tissue damage, and decreased costs. A variety of surgical procedures have emerged using minimally invasive technologies, particularly in the field of spine surgery. Areas covered: In this article, we describe the Minimal Exposure Tubular Retractor (METRx TM ) System which is a minimally invasive surgical device that utilizes a series of dilators to permit access to a surgical site of interest. This system was developed for use in treatment of disc herniation, spinal stenosis, posterior lumbar interbody fusion, transforaminal lumbar interbody fusion and spinal cord stimulation implantation. We also describe novel uses of this system for minimally invasive biopsy and treatment of benign and metastatic bone lesions at our institution. Expert commentary: Minimally invasive surgical techniques will continue to expand into the field of orthopedic oncology. With a greater number of studies proving the safety and effectiveness of this technique, the demand for minimally invasive treatments will grow.

  15. Face, content, and construct validity of four, inanimate training exercises using the da Vinci ® Si surgical system configured with Single-Site ™ instrumentation.

    PubMed

    Jarc, Anthony M; Curet, Myriam

    2015-08-01

    Validated training exercises are essential tools for surgeons as they develop technical skills to use robot-assisted minimally invasive surgical systems. The purpose of this study was to show face, content, and construct validity of four, inanimate training exercises using the da Vinci (®) Si surgical system configured with Single-Site (™) instrumentation. New (N = 21) and experienced (N = 6) surgeons participated in the study. New surgeons (11 Gynecology [GYN] and 10 General Surgery [GEN]) had not completed any da Vinci Single-Site cases but may have completed multiport cases using the da Vinci system. They participated in this study prior to attending a certification course focused on da Vinci Single-Site instrumentation. Experienced surgeons (5 GYN and 1 GEN) had completed at least 25 da Vinci Single-Site cases. The surgeons completed four inanimate training exercises and then rated them with a questionnaire. Raw metrics and overall normalized scores were computed using both video recordings and kinematic data collected from the surgical system. The experienced surgeons significantly outperformed new surgeons for many raw metrics and the overall normalized scores derived from video review (p < 0.05). Only one exercise did not achieve a significant difference between new and experienced surgeons (p = 0.08) when calculating an overall normalized score using both video and advanced metrics derived from kinematic data. Both new and experienced surgeons rated the training exercises as appearing, to train and measure technical skills used during da Vinci Single-Site surgery and actually testing the technical skills used during da Vinci Single-Site surgery. In summary, the four training exercises showed face, content, and construct validity. Improved overall scores could be developed using additional metrics not included in this study. The results suggest that the training exercises could be used in an overall training curriculum aimed at developing proficiency in

  16. Oxidation of octylphenol by ferrate(VI).

    PubMed

    Anquandah, George A K; Sharma, Virender K

    2009-01-01

    The rates of the oxidation of octylphenols (OP) by potassium ferrate(VI) (K(2)FeO(4)) in water were determined as a function of pH (8.0-10.9) at 25 degrees C. The rate law for the oxidation of OP by Fe(VI) was found to be first order with each reactant. The observed second-order rate constants, k(obs), for the oxidation of alkylphenols decreased with an increase in pH. The speciation of Fe(VI) (HFeO(4)(-) and FeO(4)(2 -)) and OP (OP-OH and OP-O(-)) species were used to determine individual rate constants of the reactions. Comparison of rate constants and half-lives of oxidation of OP by Fe(VI) with nonylphenol (NP) and bisphenol-A (BPA) were conducted to demonstrate that Fe(VI) efficiently oxidizes environmentally relevant alkylphenols in water.

  17. The Development of an Electronic Portfolio for Postgraduate Surgical Training in Flanders.

    PubMed

    Peeraer, G; Van Humbeeck, B; De Leyn, P; Delvaux, G; Hubens, G; Pattyn, P; De Win, G

    2015-01-01

    Contemporary surgical postgraduate training is characterized by clear outcomes for the profession and an assessment program that shows that trainees master these outcomes. The tool used to collect assessment and feedback instruments is the portfolio, nowadays used in many countries worldwide. The four Flemish surgical coordinators, together with experts from different universities, devised an electronic portfolio. This portfolio holds both the logbook, as imposed by the evaluation committee and assessment instruments used for the Master in Specialized Medicine. The e-portfolio is now used by a number of surgical trainees and has been approved by the evaluation committee. In 2015, all Flemish surgical trainees will be using one and the same e-portfolio. Although the e-portfolio for surgical training has now been devised and accepted by all major parties involved, a lot of work has to be done to implement the instrument. As resident duty hours show no improvement on education in surgery (but rather a perception of worsened education) surgery training is fazing huge challenges. Copyright© Acta Chirurgica Belgica.

  18. Patient-specific instrumentation in total knee arthroplasty: simpler, faster and more accurate than standard instrumentation-a randomized controlled trial.

    PubMed

    Vide, João; Freitas, Tânia Pinto; Ramos, Acácio; Cruz, Henrique; Sousa, João Paulo

    2017-08-01

    This randomized controlled trial was conducted to compare patient-specific instrumentation (PSI) to standard instrumentation regarding efficacy to achieve a good coronal alignment and differences in surgical time, blood loss and length of stay. Ninety-five of 100 randomized patients eligible for total knee arthroplasty were analysed. PSI with magnetic resonance and long-leg radiograph was performed in 47 patients, while 48 patients received standard instrumentation. Primary outcome measure was coronal alignment, evaluated with long-leg radiograph. Deviation >3° varus/valgus was considered an outlier. Surgical time was compared from skin to skin. Length of stay was a post hoc analysis. Blood loss was evaluated comparing the number of blood units spent, fall in haemoglobin and haematocrit levels. Standard instrumentation had a higher number of outliers in the coronal alignment with a relative risk of 3.015, compared to PSI. Surgical time was reduced by 18 min (24.8 %) with the PSI, as well as length of stay, with a half-day reduction. Number of blood units spent was significantly less in the PSI group. Relative risk of transfusion was 7.09 for patients in the standard instrumentation group. Difference in Hg and Htc levels were not significant. No patient had to abandon PSI. Minor changes to preoperative plan occurred in 14.9 % of the patient: cut review in 4.3 % and insert change in 10.6 %. Patient-specific instrumentation (PSI) is able to provide important advantages over standard instrumentation in total knee arthroplasty: it lowers the risk of outliers and transfusion, is a faster procedure and enables a shorter length of stay with a low rate of intraoperative adjustments. I.

  19. The biomineralization process of uranium(VI) by Saccharomyces cerevisiae - transformation from amorphous U(VI) to crystalline chernikovite.

    PubMed

    Shen, Yanghao; Zheng, Xinyan; Wang, Xiaoyu; Wang, Tieshan

    2018-05-01

    Microorganisms play a significant role in uranium(VI) biogeochemistry and influence U(VI) transformation through biomineralization. In the present work, the process of uranium mineralization was investigated by Saccharomyces cerevisiae. The toxicity experiments showed that the viability of cell was not significantly affected by 100 mg L -1 U(VI) under 4 days of exposure time. The batch experiments showed that the phosphate concentration and pH value increased over time during U(VI) adsorption. Meanwhile, thermodynamic calculations demonstrated that the adsorption system was supersaturated with respect to UO 2 HPO 4 . The X-ray powder diffraction spectroscopy (XRD), field emission scanning electron microscopy (FE-SEM) equipped with energy dispersive spectroscopy (EDX), Fourier transform infrared spectroscopy (FTIR), and X-ray photoelectron spectroscopy (XPS) analyses indicated that the U(VI) was first attached onto the cell surface and reacted with hydroxyl, carboxyl, and phosphate groups through electrostatic interactions and complexation. As the immobilization of U(VI) transformed it from the ionic to the amorphous state, lamellar uranium precipitate was formed on the cell surface. With the prolongation of time, the amorphous uranium compound disappeared, and there were some crystalline substances observed extracellularly, which were well-characterized as tetragonal-chernikovite. Furthermore, the size of chernikovite was regulated at nano-level by cells, and the perfect crystal was formed finally. These findings provided an understanding of the non-reductive transformation process of U(VI) from the amorphous to crystalline state within microbe systems, which would be beneficial for the U(VI) treatment and reuse of nuclides and heavy metals.

  20. Increased Expression of Brain-Derived Neurotrophic Factor Transcripts I and VI, cAMP Response Element Binding, and Glucocorticoid Receptor in the Cortex of Patients with Temporal Lobe Epilepsy.

    PubMed

    Martínez-Levy, G A; Rocha, L; Rodríguez-Pineda, F; Alonso-Vanegas, M A; Nani, A; Buentello-García, R M; Briones-Velasco, M; San-Juan, D; Cienfuegos, J; Cruz-Fuentes, C S

    2018-05-01

    A body of evidence supports a relevant role of brain-derived neurotrophic factor (BDNF) in temporal lobe epilepsy (TLE). Magnetic resonance data reveal that the cerebral atrophy extends to regions that are functionally and anatomically connected with the hippocampus, especially the temporal cortex. We previously reported an increased expression of BDNF messenger for the exon VI in the hippocampus of temporal lobe epilepsy patients compared to an autopsy control group. Altered levels of this particular transcript were also associated with pre-surgical use of certain psychotropic. We extended here our analysis of transcripts I, II, IV, and VI to the temporal cortex since this cerebral region holds intrinsic communication with the hippocampus and is structurally affected in patients with TLE. We also assayed the cyclic adenosine monophosphate response element-binding (CREB) and glucocorticoid receptor (GR) genes as there is experimental evidence of changes in their expression associated with BDNF and epilepsy. TLE and pre-surgical pharmacological treatment were considered as the primary clinical independent variables. Transcripts BDNF I and BDNF VI increased in the temporal cortex of patients with pharmacoresistant TLE. The expression of CREB and GR expression follow the same direction. Pre-surgical use of selective serotonin reuptake inhibitors, carbamazepine (CBZ) and valproate (VPA), was associated with the differential expression of specific BDNF transcripts and CREB and GR genes. These changes could have functional implication in the plasticity mechanisms related to temporal lobe epilepsy.

  1. Real-time mandibular angle reduction surgical simulation with haptic rendering.

    PubMed

    Wang, Qiong; Chen, Hui; Wu, Wen; Jin, Hai-Yang; Heng, Pheng-Ann

    2012-11-01

    Mandibular angle reduction is a popular and efficient procedure widely used to alter the facial contour. The primary surgical instruments, the reciprocating saw and the round burr, employed in the surgery have a common feature: operating at a high-speed. Generally, inexperienced surgeons need a long-time practice to learn how to minimize the risks caused by the uncontrolled contacts and cutting motions in manipulation of instruments with high-speed reciprocation or rotation. A virtual reality-based surgical simulator for the mandibular angle reduction was designed and implemented on a CUDA-based platform in this paper. High-fidelity visual and haptic feedbacks are provided to enhance the perception in a realistic virtual surgical environment. The impulse-based haptic models were employed to simulate the contact forces and torques on the instruments. It provides convincing haptic sensation for surgeons to control the instruments under different reciprocation or rotation velocities. The real-time methods for bone removal and reconstruction during surgical procedures have been proposed to support realistic visual feedbacks. The simulated contact forces were verified by comparing against the actual force data measured through the constructed mechanical platform. An empirical study based on the patient-specific data was conducted to evaluate the ability of the proposed system in training surgeons with various experiences. The results confirm the validity of our simulator.

  2. Technology-derived storage solutions for stabilizing insulin in extreme weather conditions I: the ViViCap-1 device.

    PubMed

    Pfützner, Andreas; Pesach, Gidi; Nagar, Ron

    2017-06-01

    Injectable life-saving drugs should not be exposed to temperatures <4°C/39°F or >30°C/86°F. Frequently, weather conditions exceed these temperature thresholds in many countries. Insulin is to be kept at 4-8°C/~ 39-47°F until use and once opened, is supposed to be stable for up to 31 days at room temperature (exception: 42 days for insulin levemir). Extremely hot or cold external temperature can lead to insulin degradation in a very short time with loss of its glucose-lowering efficacy. Combined chemical and engineering solutions for heat protection are employed in ViViCap-1 for disposable insulin pens. The device works based on vacuum insulation and heat consumption by phase-change material. Laboratory studies with exposure of ViViCap-1 to hot outside conditions were performed to evaluate the device performance. ViViCap-1 keeps insulin at an internal temperature < 29°C/84.2°F for a minimum of 12 h without external power requirement, even when constantly exposed to an outside temperature of 37.8°C/100°F. Bringing the device into an ambient temperature < 26°C/78.8°F reverses the phase-change process and 'recharges' the device for further use. ViViCap-1 performed within its specifications. The small and convenient device maintains the efficacy and safety of using insulin even when carried under hot weather conditions.

  3. The Vi conjugate typhoid vaccine is safe, elicits protective levels of IgG anti-Vi, and is compatible with routine infant vaccines.

    PubMed

    Thiem, Vu Dinh; Lin, Feng-Ying C; Canh, Do Gia; Son, Nguyen Hong; Anh, Dang Duc; Mao, Nguyen Duc; Chu, Chiayung; Hunt, Steven W; Robbins, John B; Schneerson, Rachel; Szu, Shousun C

    2011-05-01

    Typhoid fever remains a serious problem in developing countries. Current vaccines are licensed for individuals who are 5 years old or older. A conjugate of the capsular polysaccharide (CP) of Salmonella enterica serovar Typhi (Vi) bound to recombinant exoprotein A of Pseudomonas aeruginosa (Vi-rEPA) enhanced Vi immunogenicity and protected 2- to 5-year-olds in Vietnam. In this study, Vi-rEPA was evaluated for use in infants. A total of 301 full-term Vietnamese infants received Expanded Program on Immunization (EPI) vaccines alone or with Vi-rEPA or Haemophilus influenzae type b-tetanus toxoid conjugate (Hib-TT) at 2, 4, and 6 months and Vi-rEPA or Hib-TT alone at 12 months. Infants were visited 6, 24, and 48 h after each injection to monitor adverse reactions. Maternal, cord, and infant sera were assayed for IgG anti-Vi and for IgG antibodies to Hib CP and the diphtheria, tetanus, and pertussis toxins at 7, 12, and 13 months. No vaccine-related serious adverse reactions occurred. In the Vi-rEPA group, the IgG anti-Vi geometric mean (GM) increased from the cord level of 0.66 to 17.4 enzyme-linked immunosorbent assay units (EU) at 7 months, declined to 4.76 EU at 12 months, and increased to 50.1 EU 1 month after the 4th dose (95% of infants had levels of ≥ 3.5 EU, the estimated protective level). Controls had no increase of the IgG anti-Vi GM. Infants with cord anti-Vi levels of <3.5 EU responded with significantly higher IgG anti-Vi levels than those with levels of ≥ 3.5 EU. Anti-diphtheria, -tetanus, and -pertussis toxin levels were similar in all groups. Vi-rEPA was safe, induced protective anti-Vi levels, and was compatible with EPI vaccines, and it can be used in infants. High cord IgG anti-Vi levels partially suppressed infant responses to Vi-rEPA.

  4. Cervical Spine Instrumentation in Children.

    PubMed

    Hedequist, Daniel J; Emans, John B

    2016-06-01

    Instrumentation of the cervical spine enhances stability and improves arthrodesis rates in children undergoing surgery for deformity or instability. Various morphologic and clinical studies have been conducted in children, confirming the feasibility of anterior or posterior instrumentation of the cervical spine with modern implants. Knowledge of the relevant spine anatomy and preoperative imaging studies can aid the clinician in understanding the pitfalls of instrumentation for each patient. Preoperative planning, intraoperative positioning, and adherence to strict surgical techniques are required given the small size of children. Instrumentation options include anterior plating, occipital plating, and a variety of posterior screw techniques. Complications related to screw malposition include injury to the vertebral artery, neurologic injury, and instrumentation failure.

  5. 21 CFR 872.4120 - Bone cutting instrument and accessories.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Bone cutting instrument and accessories. 872.4120... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Surgical Devices § 872.4120 Bone cutting instrument and accessories. (a) Identification. A bone cutting instrument and accessories is a metal device intended for use...

  6. 21 CFR 872.4120 - Bone cutting instrument and accessories.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Bone cutting instrument and accessories. 872.4120... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Surgical Devices § 872.4120 Bone cutting instrument and accessories. (a) Identification. A bone cutting instrument and accessories is a metal device intended for use...

  7. 21 CFR 872.4120 - Bone cutting instrument and accessories.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Bone cutting instrument and accessories. 872.4120... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Surgical Devices § 872.4120 Bone cutting instrument and accessories. (a) Identification. A bone cutting instrument and accessories is a metal device intended for use...

  8. 21 CFR 872.4120 - Bone cutting instrument and accessories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Bone cutting instrument and accessories. 872.4120... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Surgical Devices § 872.4120 Bone cutting instrument and accessories. (a) Identification. A bone cutting instrument and accessories is a metal device intended for use...

  9. 21 CFR 872.4120 - Bone cutting instrument and accessories.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Bone cutting instrument and accessories. 872.4120... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Surgical Devices § 872.4120 Bone cutting instrument and accessories. (a) Identification. A bone cutting instrument and accessories is a metal device intended for use...

  10. 21 CFR 882.4200 - Clip removal instrument.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Clip removal instrument. 882.4200 Section 882.4200 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4200 Clip removal instrument. (a...

  11. 21 CFR 882.4275 - Dowel cutting instrument.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Dowel cutting instrument. 882.4275 Section 882.4275 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4275 Dowel cutting instrument. (a...

  12. 21 CFR 882.4200 - Clip removal instrument.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Clip removal instrument. 882.4200 Section 882.4200 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4200 Clip removal instrument. (a...

  13. 21 CFR 888.5960 - Cast removal instrument.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Cast removal instrument. 888.5960 Section 888.5960 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Surgical Devices § 888.5960 Cast removal instrument. (a) Identification...

  14. 21 CFR 888.5960 - Cast removal instrument.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Cast removal instrument. 888.5960 Section 888.5960 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Surgical Devices § 888.5960 Cast removal instrument. (a) Identification...

  15. 21 CFR 888.5960 - Cast removal instrument.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Cast removal instrument. 888.5960 Section 888.5960 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Surgical Devices § 888.5960 Cast removal instrument. (a) Identification...

  16. 21 CFR 888.5960 - Cast removal instrument.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Cast removal instrument. 888.5960 Section 888.5960 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Surgical Devices § 888.5960 Cast removal instrument. (a) Identification...

  17. Factors Affecting Formation of Incomplete Vi Antibody in Mice

    PubMed Central

    Gaines, Sidney; Currie, Julius A.; Tully, Joseph G.

    1965-01-01

    Gaines, Sidney (Walter Reed Army Institute of Research, Washington, D.C.), Julius A. Currie, and Joseph G. Tully. Factors affecting formation of incomplete Vi antibody in mice. J. Bacteriol. 90:635–642. 1965.—Single immunizing doses of purified Vi antigen elicited complete and incomplete Vi antibodies in BALB/c mice, but only incomplete antibody in Cinnamon mice. Three of six other mouse strains tested responded like BALB/c mice; the remaining three, like Cinnamon mice. Varying the quantity of antigen injected or the route of administration failed to stimulate the production of detectable complete Vi antibody in Cinnamon mice. Such antibody was evoked in these animals by multiple injections of Vi antigen or by inoculating them with Vi-containing bacilli or Vi-coated erythrocytes. The early protection afforded by serum from Vi-immunized BALB/c mice coincided with the appearance of incomplete Vi antibody, 1 day prior to the advent of complete antibody. Persistence of incomplete as well as complete antibody in the serum of immunized mice was demonstrated for at least 56 days after injection of 10 μg of Vi antigen. Incomplete Vi antibody was shown to have blocking ability, in vitro bactericidal activity, and the capability of protecting mice against intracerebral as well as intraperitoneal challenge with virulent typhoid bacilli. Production of incomplete and complete Vi antibodies was adversely affected by immunization with partially depolymerized Vi antigens. PMID:16562060

  18. Effect of uranium(VI) speciation on simultaneous microbial reduction of uranium(VI) and iron(III).

    PubMed

    Stewart, Brandy D; Amos, Richard T; Fendorf, Scott

    2011-01-01

    Uranium is a pollutant of concern to both human and ecosystem health. Uranium's redox state often dictates whether it will reside in the aqueous or solid phase and thus plays an integral role in the mobility of uranium within the environment. In anaerobic environments, the more oxidized and mobile form of uranium (UO2(2+) and associated species) may be reduced, directly or indirectly, by microorganisms to U(IV) with subsequent precipitation of UO. However, various factors within soils and sediments, such as U(VI) speciation and the presence of competitive electron acceptors, may limit biological reduction of U(VI). Here we examine simultaneous dissimilatory reduction of Fe(III) and U(VI) in batch systems containing dissolved uranyl acetate and ferrihydrite-coated sand. Varying amounts of calcium were added to induce changes in aqueous U(VI) speciation. The amount of uranium removed from solution during 100 h of incubation with S. putrefaciens was 77% in absence of Ca or ferrihydrite, but only 24% (with ferrihydrite) and 14% (without ferrihydrite) were removed for systems with 0.8 mM Ca. Dissimilatory reduction of Fe(III) and U(VI) proceed through different enzyme pathways within one type of organism. We quantified the rate coefficients for simultaneous dissimilatory reduction of Fe(III) and U(VI) in systems varying in Ca concecentration (0-0.8 mM). The mathematical construct, implemented with the reactive transport code MIN3P, reveals predominant factors controlling rates and extent of uranium reduction in complex geochemical systems.

  19. 77 FR 52116 - Title VI; Final Circular

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-28

    ... DEPARTMENT OF TRANSPORTATION Federal Transit Administration [Docket No. FTA-2011-0054] Title VI... Web site, guidance in the form of a Circular to assist grantees in complying with Title VI of the... Title VI regulations (49 CFR part 21). DATES: Effective Date: The effective date of the Circular is...

  20. Surgical task analysis of simulated laparoscopic cholecystectomy with a navigation system.

    PubMed

    Sugino, T; Kawahira, H; Nakamura, R

    2014-09-01

       Advanced surgical procedures, which have become complex and difficult, increase the burden of surgeons. Quantitative analysis of surgical procedures can improve training, reduce variability, and enable optimization of surgical procedures. To this end, a surgical task analysis system was developed that uses only surgical navigation information.    Division of the surgical procedure, task progress analysis, and task efficiency analysis were done. First, the procedure was divided into five stages. Second, the operating time and progress rate were recorded to document task progress during specific stages, including the dissecting task. Third, the speed of the surgical instrument motion (mean velocity and acceleration), as well as the size and overlap ratio of the approximate ellipse of the location log data distribution, was computed to estimate the task efficiency during each stage. These analysis methods were evaluated based on experimental validation with two groups of surgeons, i.e., skilled and "other" surgeons. The performance metrics and analytical parameters included incidents during the operation, the surgical environment, and the surgeon's skills or habits.    Comparison of groups revealed that skilled surgeons tended to perform the procedure in less time and involved smaller regions; they also manipulated the surgical instruments more gently.    Surgical task analysis developed for quantitative assessment of surgical procedures and surgical performance may provide practical methods and metrics for objective evaluation of surgical expertise.

  1. Kinetic investigations of quinoline oxidation by ferrate(VI).

    PubMed

    Luo, Zhiyong; Li, Xueming; Zhai, Jun

    2016-01-01

    Quinoline is considered as one of the most toxic and carcinogenic compounds and is commonly found in industrial wastewaters, which require treatment before being discharged. Removal of quinoline by the use of an environmentally friendly oxidant, potassium ferrate(VI) (K2FeO4), was assessed by studying the kinetics of the oxidation of quinoline by ferrate(VI) (Fe(VI)) as a function of pH (8.53-10.53) and temperature (21-36°C) in this work. The reaction of quinoline with Fe(VI) was found to be first order in Fe(VI), half order in quinoline, and 1.5 order overall. The observed rate constant at 28°C decreased non-linearly from 0.5334 to 0.2365 M(-0.5) min(-1) with an increase in pH from 8.53 to 10.03. Considering the equilibria of Fe(VI) and quinoline, the reaction between quinoline and Fe(VI) contained two parallel reactions under the given pH conditions. The individual rate constants of these two reactions were determined. The results indicate that the protonated species of Fe(VI) reacts more quickly with quinoline than the deprotonated form of Fe(VI). The reaction activation energy Ea was obtained to be 51.44 kJ·mol(-1), and it was slightly lower than that of conventional chemical reaction. It reveals that the oxidation of quinoline by Fe(VI) is feasible in the routine water treatment.

  2. Identifying the need for a multidisciplinary approach for early recognition of mucopolysaccharidosis VI (MPS VI).

    PubMed

    Choy, Yew Sing; Bhattacharya, Kaustuv; Balasubramaniam, Shanti; Fietz, Michael; Fu, Antony; Inwood, Anita; Jin, Dong-Kyu; Kim, Ok-Hwa; Kosuga, Motomichi; Kwun, Young Hee; Lin, Hsiang-Yu; Lin, Shuan-Pei; Mendelsohn, Nancy J; Okuyama, Torayuki; Samion, Hasri; Tan, Adeline; Tanaka, Akemi; Thamkunanon, Verasak; Thong, Meow-Keong; Toh, Teck-Hock; Yang, Albert D; McGill, Jim

    2015-05-01

    Mucopolysaccharidosis VI (MPS VI, Maroteaux-Lamy syndrome) is caused by deficient activity of the enzyme, N-acetylgalactosamine-4-sulfatase, resulting in impaired degradation of the glycosaminoglycan dermatan sulfate. Patients experience a range of manifestations including joint contractures, short stature, dysostosis multiplex, coarse facial features, decreased pulmonary function, cardiac abnormalities, corneal clouding and shortened life span. Recently, clinicians from institutions in the Asia-Pacific region met to discuss the occurrence and implications of delayed diagnosis and misdiagnosis of MPS VI in the patients they have managed. Eighteen patients (44% female) were diagnosed. The most common sign presented by the patients was bone deformities in 11 patients (65%). Delays to diagnosis occurred due to the lack of or distance to diagnostic facilities for four patients (31%), alternative diagnoses for two patients (15%), and misleading symptoms experienced by two patients (15%). Several patients experienced manifestations that were subtler than would be expected and were subsequently overlooked. Several cases highlighted the unique challenges associated with diagnosing MPS VI from the perspective of different specialties and provide insights into how these patients initially present, which may help to elucidate strategies to improve the diagnosis of MPS VI. Copyright © 2015 Elsevier Inc. All rights reserved.

  3. Immunization with the conjugate vaccine Vi-CRM₁₉₇ against Salmonella typhi induces Vi-specific mucosal and systemic immune responses in mice.

    PubMed

    Fiorino, Fabio; Ciabattini, Annalisa; Rondini, Simona; Pozzi, Gianni; Martin, Laura B; Medaglini, Donata

    2012-09-21

    Typhoid fever is a public health problem, especially among young children in developing countries. To address this need, a glycoconjugate vaccine Vi-CRM₁₉₇, composed of the polysaccharide antigen Vi covalently conjugated to the non-toxic mutant of diphtheria toxin CRM₁₉₇, is under development. Here, we assessed the antibody and cellular responses, both local and systemic, following subcutaneous injection of Vi-CRM₁₉₇. The glycoconjugate elicited Vi-specific serum IgG titers significantly higher than unconjugated Vi, with prevalence of IgG1 that persisted for at least 60 days after immunization. Vi-specific IgG, but not IgA, were present in intestinal washes. Lymphocytes proliferation after restimulation with Vi-CRM₁₉₇ was observed in spleen and mesenteric lymph nodes. These data confirm the immunogenicity of Vi-CRM₁₉₇ and demonstrate that the vaccine-specific antibody and cellular immune responses are present also in the intestinal tract, thus strengthening the suitability of Vi-CRM₁₉₇ as a promising candidate vaccine against Salmonella Typhi. Copyright © 2012 Elsevier Ltd. All rights reserved.

  4. Improved alignment and operating room efficiency with patient-specific instrumentation for TKA.

    PubMed

    Renson, Luc; Poilvache, Pascal; Van den Wyngaert, Hans

    2014-12-01

    Achieving accurate alignment in total knee arthroplasty (TKA) remains a concern. Patient-specific instrumentation (PSI) produced using preoperative 3D models was developed to offer surgeons a simplified, reliable, efficient and customised TKA procedure. In this prospective study, 60 patients underwent TKA with conventional instrumentation and 71 patients were operated on using PSI. The primary endpoint was surgical time. Secondary endpoints included operating room (OR) time, the number of instrument trays used and postoperative radiographic limb alignment. Compared to conventional instrumentation, PSI significantly reduced total surgical time by 8.9 ± 3.3 min (p=0.038), OR time by 8.6 ± 4.2 min (p=0.043), and the number of instrument trays by six trays (p<0.001). Mechanical axis malalignment of the lower limb of >3° was observed in 13% of PSI patients versus 29% with conventional instrumentation (p=0.043). PSI predicted the size of the femoral and tibial components actually used in 85.9% and 78.9% of cases, respectively. PSI improves alignment, surgical and OR time, reduces the number of instruments trays used compared to conventional instrumentation in patients undergoing TKA and results in fewer outliers in overall mechanical alignment in the coronal plane. Prospective comparative therapeutic study. Copyright © 2014 Elsevier B.V. All rights reserved.

  5. Rationale, scope, and 20-year experience of vascular surgical training with lifelike pulsatile flow models.

    PubMed

    Eckstein, Hans-Henning; Schmidli, Jürg; Schumacher, Hardy; Gürke, Lorenz; Klemm, Klaus; Duschek, Nikolaus; Meile, Toni; Assadian, Afshin

    2013-05-01

    Vascular surgical training currently has to cope with various challenges, including restrictions on work hours, significant reduction of open surgical training cases in many countries, an increasing diversity of open and endovascular procedures, and distinct expectations by trainees. Even more important, patients and the public no longer accept a "learning by doing" training philosophy that leaves the learning curve on the patient's side. The Vascular International (VI) Foundation and School aims to overcome these obstacles by training conventional vascular and endovascular techniques before they are applied on patients. To achieve largely realistic training conditions, lifelike pulsatile models with exchangeable synthetic arterial inlays were created to practice carotid endarterectomy and patch plasty, open abdominal aortic aneurysm surgery, and peripheral bypass surgery, as well as for endovascular procedures, including endovascular aneurysm repair, thoracic endovascular aortic repair, peripheral balloon dilatation, and stenting. All models are equipped with a small pressure pump inside to create pulsatile flow conditions with variable peak pressures of ~90 mm Hg. The VI course schedule consists of a series of 2-hour modules teaching different open or endovascular procedures step-by-step in a standardized fashion. Trainees practice in pairs with continuous supervision and intensive advice provided by highly experienced vascular surgical trainers (trainer-to-trainee ratio is 1:4). Several evaluations of these courses show that tutor-assisted training on lifelike models in an educational-centered and motivated environment is associated with a significant increase of general and specific vascular surgical technical competence within a short period of time. Future studies should evaluate whether these benefits positively influence the future learning curve of vascular surgical trainees and clarify to what extent sophisticated models are useful to assess the level of

  6. Electrochemical alkaline Fe(VI) water purification and remediation.

    PubMed

    Licht, Stuart; Yu, Xingwen

    2005-10-15

    Fe(VI) is an unusual and strongly oxidizing form of iron, which provides a potentially less hazardous water-purifying agent than chlorine. A novel on-line electrochemical Fe(VI) water purification methodology is introduced. Fe(VI) addition had been a barrier to its effective use in water remediation, because solid Fe(VI) salts require complex (costly) syntheses steps and solutions of Fe(VI) decompose. Online electrochemical Fe(VI) water purification avoids these limitations, in which Fe(VI) is directly prepared in solution from an iron anode as the FeO42- ion, and is added to the contaminant stream. Added FeO42- decomposes, by oxidizing a wide range of water contaminants including sulfides (demonstrated in this study) and other sulfur-containing compounds, cyanides (demonstrated in this study), arsenic (demonstrated in this study), ammonia and other nitrogen-containing compounds (previously demonstrated), a wide range of organics (phenol demonstrated in this study), algae, and viruses (each previously demonstrated).

  7. Myosin VI facilitates connexin 43 gap junction accretion.

    PubMed

    Waxse, Bennett J; Sengupta, Prabuddha; Hesketh, Geoffrey G; Lippincott-Schwartz, Jennifer; Buss, Folma

    2017-03-01

    In this study, we demonstrate myosin VI enrichment at Cx43 (also known as GJA1)-containing gap junctions (GJs) in heart tissue, primary cardiomyocytes and cell culture models. In primary cardiac tissue and in fibroblasts from the myosin VI-null mouse as well as in tissue culture cells transfected with siRNA against myosin VI, we observe reduced GJ plaque size with a concomitant reduction in intercellular communication, as shown by fluorescence recovery after photobleaching (FRAP) and a new method of selective calcein administration. Analysis of the molecular role of myosin VI in Cx43 trafficking indicates that myosin VI is dispensable for the delivery of Cx43 to the cell surface and connexon movement in the plasma membrane. Furthermore, we cannot corroborate clathrin or Dab2 localization at gap junctions and we do not observe a function for the myosin-VI-Dab2 complex in clathrin-dependent endocytosis of annular gap junctions. Instead, we found that myosin VI was localized at the edge of Cx43 plaques by using total internal reflection fluorescence (TIRF) microscopy and use FRAP to identify a plaque accretion defect as the primary manifestation of myosin VI loss in Cx43 homeostasis. A fuller understanding of this derangement may explain the cardiomyopathy or gliosis associated with the loss of myosin VI. © 2017. Published by The Company of Biologists Ltd.

  8. An anthropomorphic design for a minimally invasive surgical system based on a survey of surgical technologies, techniques and training.

    PubMed

    Tzemanaki, Antonia; Walters, Peter; Pipe, Anthony Graham; Melhuish, Chris; Dogramadzi, Sanja

    2014-09-01

    Over the past century, abdominal surgery has seen a rapid transition from open procedures to less invasive methods, such as robot-assisted minimally invasive surgery (MIS). This study aimed to investigate and discuss the needs of MIS in terms of instrumentation and to inform the design of a novel instrument. A survey was conducted among surgeons regarding their opinions on surgical training, surgical systems, how satisfied they were with them and how easy they were to use. A concept for MIS robotic instrumentation was then developed and a series of focus groups with surgeons were run to discuss it. The initial prototype of the robotic instruments, herein demonstrated, comprises modular rigid links with soft joints actuated by shape memory alloy helix actuators; these instruments are controlled using a sensory hand exoskeleton. The results of the survey, as well as those of the focus groups, are presented here. A first prototype of the system was built and initial laboratory tests have been conducted in order to evaluate this approach. The analysed data from both the survey and the focus groups justify the chosen concept of an anthropomorphic MIS robotic system which imitates the natural motion of the hands. Copyright © 2013 John Wiley & Sons, Ltd.

  9. Analysis of key technologies for virtual instruments metrology

    NASA Astrophysics Data System (ADS)

    Liu, Guixiong; Xu, Qingui; Gao, Furong; Guan, Qiuju; Fang, Qiang

    2008-12-01

    Virtual instruments (VIs) require metrological verification when applied as measuring instruments. Owing to the software-centered architecture, metrological evaluation of VIs includes two aspects: measurement functions and software characteristics. Complexity of software imposes difficulties on metrological testing of VIs. Key approaches and technologies for metrology evaluation of virtual instruments are investigated and analyzed in this paper. The principal issue is evaluation of measurement uncertainty. The nature and regularity of measurement uncertainty caused by software and algorithms can be evaluated by modeling, simulation, analysis, testing and statistics with support of powerful computing capability of PC. Another concern is evaluation of software features like correctness, reliability, stability, security and real-time of VIs. Technologies from software engineering, software testing and computer security domain can be used for these purposes. For example, a variety of black-box testing, white-box testing and modeling approaches can be used to evaluate the reliability of modules, components, applications and the whole VI software. The security of a VI can be assessed by methods like vulnerability scanning and penetration analysis. In order to facilitate metrology institutions to perform metrological verification of VIs efficiently, an automatic metrological tool for the above validation is essential. Based on technologies of numerical simulation, software testing and system benchmarking, a framework for the automatic tool is proposed in this paper. Investigation on implementation of existing automatic tools that perform calculation of measurement uncertainty, software testing and security assessment demonstrates the feasibility of the automatic framework advanced.

  10. Biosorption of Cr(VI) by coconut coir: spectroscopic investigation on the reaction mechanism of Cr(VI) with lignocellulosic material.

    PubMed

    Shen, Ying-Shuian; Wang, Shan-Li; Huang, Shiuh-Tsuen; Tzou, Yu-Min; Huang, Jang-Hung

    2010-07-15

    In this study, the removal mechanism of Cr(VI) from water by coconut coir (CC) was investigated using X-ray photoelectron spectroscopy (XPS), Cr K-edge X-ray absorption near edge structure (XANES) and FTIR spectroscopy. The results showed that, upon reaction with CC at pH 3, Cr(VI) was reduced to Cr(III), which was either bound to CC or released back into solution. As revealed by the FTIR spectra of CC before and after reacting with Cr(VI), the phenolic methoxyl and hydroxyl groups of lignin in CC are the dominant drivers of Cr(VI) reduction, giving rise to carbonyl and carboxyl groups on CC. These functional groups can subsequently provide binding sites for Cr(III) resulting from Cr(VI) reduction. In conjunction with forming complexes with carbonyl and carboxyl groups, the formation of Cr(III) hydroxide precipitate could also readily occur as revealed by the linear combination fitting of the Cr K-edge XANES spectrum using a set of reference compounds. The phenolic groups in lignin are responsible for initiating Cr(VI) reduction, so lignocellulosic materials containing a higher amount of phenolic groups are expected to be more effective scavengers for removal of Cr(VI) from the environment. 2010 Elsevier B.V. All rights reserved.

  11. Integration of a Spectral Domain Optical Coherence Tomography System into a Surgical Microscope for Intraoperative Imaging

    PubMed Central

    Ehlers, Justis P.; Tao, Yuankai K.; Farsiu, Sina; Maldonado, Ramiro; Izatt, Joseph A.

    2011-01-01

    Purpose. To demonstrate an operating microscope-mounted spectral domain optical coherence tomography (MMOCT) system for human retinal and model surgery imaging. Methods. A prototype MMOCT system was developed to interface directly with an ophthalmic surgical microscope, to allow SDOCT imaging during surgical viewing. Nonoperative MMOCT imaging was performed in an Institutional Review Board–approved protocol in four healthy volunteers. The effect of surgical instrument materials on MMOCT imaging was evaluated while performing retinal surface, intraretinal, and subretinal maneuvers in cadaveric porcine eyes. The instruments included forceps, metallic and polyamide subretinal needles, and soft silicone-tipped instruments, with and without diamond dusting. Results. High-resolution images of the human retina were successfully obtained with the MMOCT system. The optical properties of surgical instruments affected the visualization of the instrument and the underlying retina. Metallic instruments (e.g., forceps and needles) showed high reflectivity with total shadowing below the instrument. Polyamide material had a moderate reflectivity with subtotal shadowing. Silicone instrumentation showed moderate reflectivity with minimal shadowing. Summed voxel projection MMOCT images provided clear visualization of the instruments, whereas the B-scans from the volume revealed details of the interactions between the tissues and the instrumentation (e.g., subretinal space cannulation, retinal elevation, or retinal holes). Conclusions. High-quality retinal imaging is feasible with an MMOCT system. Intraoperative imaging with model eyes provides high-resolution depth information including visualization of the instrument and intraoperative tissue manipulation. This study demonstrates a key component of an interactive platform that could provide enhanced information for the vitreoretinal surgeon. PMID:21282565

  12. Integration of a spectral domain optical coherence tomography system into a surgical microscope for intraoperative imaging.

    PubMed

    Ehlers, Justis P; Tao, Yuankai K; Farsiu, Sina; Maldonado, Ramiro; Izatt, Joseph A; Toth, Cynthia A

    2011-05-16

    To demonstrate an operating microscope-mounted spectral domain optical coherence tomography (MMOCT) system for human retinal and model surgery imaging. A prototype MMOCT system was developed to interface directly with an ophthalmic surgical microscope, to allow SDOCT imaging during surgical viewing. Nonoperative MMOCT imaging was performed in an Institutional Review Board-approved protocol in four healthy volunteers. The effect of surgical instrument materials on MMOCT imaging was evaluated while performing retinal surface, intraretinal, and subretinal maneuvers in cadaveric porcine eyes. The instruments included forceps, metallic and polyamide subretinal needles, and soft silicone-tipped instruments, with and without diamond dusting. High-resolution images of the human retina were successfully obtained with the MMOCT system. The optical properties of surgical instruments affected the visualization of the instrument and the underlying retina. Metallic instruments (e.g., forceps and needles) showed high reflectivity with total shadowing below the instrument. Polyamide material had a moderate reflectivity with subtotal shadowing. Silicone instrumentation showed moderate reflectivity with minimal shadowing. Summed voxel projection MMOCT images provided clear visualization of the instruments, whereas the B-scans from the volume revealed details of the interactions between the tissues and the instrumentation (e.g., subretinal space cannulation, retinal elevation, or retinal holes). High-quality retinal imaging is feasible with an MMOCT system. Intraoperative imaging with model eyes provides high-resolution depth information including visualization of the instrument and intraoperative tissue manipulation. This study demonstrates a key component of an interactive platform that could provide enhanced information for the vitreoretinal surgeon.

  13. 21 CFR 888.5980 - Manual cast application and removal instrument.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Manual cast application and removal instrument... SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Surgical Devices § 888.5980 Manual cast application and removal instrument. (a) Identification. A manual cast application and removal instrument is a...

  14. Surgical Videos with Synchronised Vertical 2-Split Screens Recording the Surgeons' Hand Movement.

    PubMed

    Kaneko, Hiroki; Ra, Eimei; Kawano, Kenichi; Yasukawa, Tsutomu; Takayama, Kei; Iwase, Takeshi; Terasaki, Hiroko

    2015-01-01

    To improve the state-of-the-art teaching system by creating surgical videos with synchronised vertical 2-split screens. An ultra-compact, wide-angle point-of-view camcorder (HX-A1, Panasonic) was mounted on the surgical microscope focusing mostly on the surgeons' hand movements. In combination with the regular surgical videos obtained from the CCD camera in the surgical microscope, synchronised vertical 2-split-screen surgical videos were generated with the video-editing software. Using synchronised vertical 2-split-screen videos, residents of the ophthalmology department could watch and learn how assistant surgeons controlled the eyeball, while the main surgeons performed scleral buckling surgery. In vitrectomy, the synchronised vertical 2-split-screen videos showed the surgeons' hands holding the instruments and moving roughly and boldly, in contrast to the very delicate movements of the vitrectomy instruments inside the eye. Synchronised vertical 2-split-screen surgical videos are beneficial for the education of young surgical trainees when learning surgical skills including the surgeons' hand movements. © 2015 S. Karger AG, Basel.

  15. Non-photorealistic rendering of virtual implant models for computer-assisted fluoroscopy-based surgical procedures

    NASA Astrophysics Data System (ADS)

    Zheng, Guoyan

    2007-03-01

    Surgical navigation systems visualize the positions and orientations of surgical instruments and implants as graphical overlays onto a medical image of the operated anatomy on a computer monitor. The orthopaedic surgical navigation systems could be categorized according to the image modalities that are used for the visualization of surgical action. In the so-called CT-based systems or 'surgeon-defined anatomy' based systems, where a 3D volume or surface representation of the operated anatomy could be constructed from the preoperatively acquired tomographic data or through intraoperatively digitized anatomy landmarks, a photorealistic rendering of the surgical action has been identified to greatly improve usability of these navigation systems. However, this may not hold true when the virtual representation of surgical instruments and implants is superimposed onto 2D projection images in a fluoroscopy-based navigation system due to the so-called image occlusion problem. Image occlusion occurs when the field of view of the fluoroscopic image is occupied by the virtual representation of surgical implants or instruments. In these situations, the surgeon may miss part of the image details, even if transparency and/or wire-frame rendering is used. In this paper, we propose to use non-photorealistic rendering to overcome this difficulty. Laboratory testing results on foamed plastic bones during various computer-assisted fluoroscopybased surgical procedures including total hip arthroplasty and long bone fracture reduction and osteosynthesis are shown.

  16. Title VI Summary 2000-2001.

    ERIC Educational Resources Information Center

    Huskey, Barton

    Title VI provides federal funds to states under the Elementary and Secondary Education Act of 1965. This document describes Title VI programs and the use of funds in the Austin Independent School District (AISD), Texas for 2000-2001. The AISD allocation of $481,559 was based on the May 2000 projected school enrollment, including projected…

  17. Use of 3 mm percutaneous instruments with 5 mm end effectors during different laparoscopic procedures.

    PubMed

    David, Giulia; Boni, Luigi; Rausei, Stefano; Cassinotti, Elisa; Dionigi, Gianlorenzo; Rovera, Francesca; Spampatti, Sebastiano; Colombo, Elisabetta Marta; Dionigi, Renzo

    2013-01-01

    With a recent focus on minimizing the visibility of scars, new techniques have been developed. Minilaparoscopy reemerged as an attractive option for surgery as it limits tissue trauma, reduces post-operative pain and improves cosmesis. This study was designed to describe our experience with percutaneous trocarless 3 mm instruments used in combination with standard 5 mm and 10 mm laparoscopic instruments in different general surgery procedures. We used the PSS (Percutaneous Surgical Set, Ethicon Endo surgery, Cincinnati, OH, USA) in different surgical procedures as accessory instruments in combination with standard 5 mm and 10 mm standard laparoscopic instruments. The use of percutaneous instruments was safe and feasible in all performed procedures. The surgical technique was not modified. The percutaneous instruments can assure a good grip and can be used for traction and counter-traction. No complications have been described. No pain at the site of insertion has been reported. The skin, muscle and peritoneal defects were smaller than with the 3 mm laparoscopic traditional instruments. Percutaneous approach seems to be a good option in general surgery in terms of efficiency, offering better cosmetic results and good pain control. Copyright © 2013 Elsevier Ltd and Surgical Associates Ltd. All rights reserved.

  18. The Model VI transmission fluorimeter for the determination of uranium

    USGS Publications Warehouse

    Kinser, Charles Alvin

    1954-01-01

    An improved transmission fluorimeter (Model VI) for use in the determination of uranium consists of a line-operated, low-voltage d-c supply, powering a small 3-watt ultraviolet lamp as a source of long wavelength ultraviolet radiation; a Model V phototube housing and. fluorimeter head containing the sample holder, shutter, and primary and secondary filters; an end-window multiplier phototube powered by a stable, commercially available high-voltage supply; and an electronic microammeter for measuring the output current from the photomultiplier tube. The instrument has excellent electrical stability and operates over a wide range of sensitivity. Its versatility makes it useful for both routine and research work.

  19. No difference in mechanical alignment and femoral component placement between patient-specific instrumentation and conventional instrumentation in TKA.

    PubMed

    Fu, Huichao; Wang, Jiaxing; Zhou, Shenyuan; Cheng, Tao; Zhang, Wen; Wang, Qi; Zhang, Xianlong

    2015-11-01

    There is a rising interest in the use of patient-specific instrumentation (PSI) during total knee arthroplasty (TKA). The goal of this meta-analysis was to compare PSI with conventional instrumentation (CI) in patients undergoing TKA. A literature search was performed in PubMed, Embase, Springer, Ovid, China National Knowledge Infrastructure, and the Cochrane Library. A total of 10 randomized controlled studies involving 837 knees comparing outcomes of PSI TKAs with CI TKAs were included in the present analysis. Outcomes of interest included component alignment, surgical time, blood loss, and hospital stay. The results presented no significant differences between the two instrumentations in terms of restoring a neutral mechanical axis and femoral component placement. However, their differences have been noted regarding the alignment of the tibial component in coronal and sagittal planes. Also, 3 min less surgical time was used in PSI patients. Based on these findings, PSI appeared not to be superior to CI in terms of the post-operative mechanical axis of the limb or femoral component placement. Despite a statistical difference for operative duration, the benefit of a small reduction in surgical time with PSI is clinically irrelevant. Therapeutic study (systematic review and meta-analysis), Level I.

  20. The adsorption behavior of U(VI) on granite.

    PubMed

    Fan, Q H; Hao, L M; Wang, C L; Zheng, Z; Liu, C L; Wu, W S

    2014-03-01

    The effects of pH, counter ions and temperature on the adsorption of U(VI) on Beishan granite (BsG) were investigated in the presence and absence of fulvic acid (FA) and humic acid (HA). The adsorption edge of U(VI) on BsG suggested that U(VI) adsorption was mainly controlled by ion exchange and outer-sphere complexation at low pH, whereas inner-sphere complex was the dominant adsorption species in the pH range of 4.0-9.0. Above pH 9.0, Na2U2O7 might play an important role in the rise of U(VI) adsorption again. Counter ions such as Cl(-), SO4(2-) and PO4(3-) can provoke U(VI) adsorption on BsG to some extent, which was directly correlated to the complexing ability of U(VI)-ligand. More noticeably, the large enhancement of U(VI) adsorption in the presence of phosphate can be attributed to the ternary complex formation (BsG-PO4-UO2), precipitation ((UO2)3(PO4)2(s)) and secondary phase (Na-autunite). Both FA and HA can slightly increase U(VI) adsorption at low pH, whereas they strongly inhibited U(VI) adsorption at high pH range. Artificial synthesized granite (AsG) prepared in the laboratory is impossible to use as an analogue of natural granite because of the large difference in the adsorption and surface properties.

  1. Reactivity of nitrido complexes of ruthenium(VI), osmium(VI), and manganese(V) bearing Schiff base and simple anionic ligands.

    PubMed

    Man, Wai-Lun; Lam, William W Y; Lau, Tai-Chu

    2014-02-18

    Nitrido complexes (M≡N) may be key intermediates in chemical and biological nitrogen fixation and serve as useful reagents for nitrogenation of organic compounds. Osmium(VI) nitrido complexes bearing 2,2':6',2″-terpyridine (terpy), 2,2'-bipyridine (bpy), or hydrotris(1-pyrazolyl)borate anion (Tp) ligands are highly electrophilic: they can react with a variety of nucleophiles to generate novel osmium(IV)/(V) complexes. This Account describes our recent results studying the reactivity of nitridocomplexes of ruthenium(VI), osmium(VI), and manganese(V) that bear Schiff bases and other simple anionic ligands. We demonstrate that these nitrido complexes exhibit rich chemical reactivity. They react with various nucleophiles, activate C-H bonds, undergo N···N coupling, catalyze the oxidation of organic compounds, and show anticancer activities. Ruthenium(VI) nitrido complexes bearing Schiff base ligands, such as [Ru(VI)(N)(salchda)(CH3OH)](+) (salchda = N,N'-bis(salicylidene)o-cyclohexyldiamine dianion), are highly electrophilic. This complex reacts readily at ambient conditions with a variety of nucleophiles at rates that are much faster than similar reactions using Os(VI)≡N. This complex also carries out unique reactions, including the direct aziridination of alkenes, C-H bond activation of alkanes and C-N bond cleavage of anilines. The addition of ligands such as pyridine can enhance the reactivity of [Ru(VI)(N)(salchda)(CH3OH)](+). Therefore researchers can tune the reactivity of Ru≡N by adding a ligand L trans to nitride: L-Ru≡N. Moreover, the addition of various nucleophiles (Nu) to Ru(VI)≡N initially generate the ruthenium(IV) imido species Ru(IV)-N(Nu), a new class of hydrogen-atom transfer (HAT) reagents. Nucleophiles also readily add to coordinated Schiff base ligands in Os(VI)≡N and Ru(VI)≡N complexes. These additions are often stereospecific, suggesting that the nitrido ligand has a directing effect on the incoming nucleophile. M≡N is also

  2. Ferrate(VI) oxidation of cyanide in water.

    PubMed

    Costarramone, N; Kneip, A; Castetbon, A

    2004-08-01

    Experiments were conducted to test removal of cyanide (free cyanide and several cyanide complexes) in water, under alkaline medium (pH > or = 11), by a new potassium ferrate salt. The removal rate of free cyanide by oxidation with Fe(VI) was greater at pH 11.0 than at pH 12.0. A complete oxidation was obtained with a 2.67 Fe(VI)/CN ratio at pH 11.0. In these conditions, the rate of cyanide oxidation by Fe(VI) was slow, with a reaction rate constant estimated at 0.95 +/- 0.10 s(-1) l mol(-1) at pH 11.0 and 19.6 degrees C in this study. This study revealed that Fe(VI) did not decompose all cyanide complexes. Copper, cadmium and zinc complexes were removed efficiently by Fe(VI). Moreover, these metals were also removed from the solution by coagulation effect of Fe(OH)3, the Fe(VI) product of reaction. A particular behaviour was reported with copper, as a rapid oxidation of cyanide was observed in the presence of this metal. On the contrary, oxidation of nickel and silver complexes was incomplete.

  3. Mechanisms of chromium (VI)-induced apoptosis in anterior pituitary cells.

    PubMed

    Quinteros, Fernanda A; Machiavelli, Leticia I; Miler, Eliana A; Cabilla, Jimena P; Duvilanski, Beatriz H

    2008-07-30

    Hexavalent chromium (Cr (VI)) is a highly toxic metal. Exposure to Cr (VI) compounds may affect reproductive functions. Due to the importance of anterior pituitary hormones on reproductive physiology we have studied the effects of Cr (VI) on anterior pituitary. We previously demonstrated that, after in vivo Cr (VI) administration, Cr accumulates in the pituitary gland and affects prolactin secretion. In vitro, Cr (VI) causes apoptosis in anterior pituitary cells due to oxidative stress generation. To better understand the mechanisms involved in Cr (VI)-induced apoptosis we studied: (a) whether Cr (VI) affects the intracellular antioxidant response and (b) which of the apoptotic factors participates in Cr (VI) effect. Our results show that Cr (VI) treatment induces a decrease in catalase and glutathione peroxidase (GPx) activity but does not modify glutathione reductase (GR) activity. Cr (VI) exposure causes an increase of GSH levels. p53 and Bax mRNA are also upregulated by the metal. Pifithrin alpha, a p53 transcriptional inhibitor, increases Cr (VI) cytotoxicity, suggesting a role of p53 as a survival molecule. The antioxidant N-acetyl-cysteine (NAC) could prevent Bax mRNA increase and caspase 3 activation, confirming that Cr (VI)-induced apoptosis involves oxidative stress generation.

  4. Emissions of chromium (VI) from arc welding.

    PubMed

    Heung, William; Yun, Myoung-Jin; Chang, Daniel P Y; Green, Peter G; Halm, Chris

    2007-02-01

    The presence of Cr in the +6 oxidation state (Cr[VI]) is still observed in ambient air samples in California despite steps taken to reduce emissions from plating operations. One known source of emission of Cr(VI) is welding, especially with high Cr-content materials, such as stainless steels. An experimental effort was undertaken to expand and update Cr(VI) emission factors by conducting tests on four types of arc-welding operations: gas-metal arc welding (GMAW), shielded metal arc welding (SMAW), fluxcore arc welding, and pulsed GMAW. Standard American Welding Society hood results were compared with a total enclosure method that permitted isokinetic sampling for particle size-cut measurement, as well as total collection of the aerosol. The fraction of Cr(VI) emitted per unit mass of Cr electrode consumed was determined. Consistent with AP-42 data, initial results indicate that a significant fraction of the total Cr in the aerosol is in the +6 oxidation state. The fraction of Cr(VI) and total aerosol mass produced by the different arc welding methods varies with the type of welding process used. Self-shielded electrodes that do not use a shield gas, for example, SMAW, produce greater amounts of Cr(VI) per unit mass of electrode consumed. The formation of Cr(VI) from standard electrode wires used for welding mild steel was below the method detection limit after eliminating an artifact in the analytical method used.

  5. Surgical Robotics Research in Cardiovascular Disease

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pohost, Gerald M; Guthrie, Barton L; Steiner, Charles

    This grant is to support a research in robotics at three major medical centers: the University of Southern California-USC- (Project 1); the University of Alabama at Birmingham-UAB-(Project 2); and the Cleveland Clinic Foundation-CCF-(Project 3). Project 1 is oriented toward cardiovascular applications, while projects 2 and 3 are oriented toward neurosurgical applications. The main objective of Project 1 is to develop an approach to assist patients in maintaining a constant level of stress while undergoing magnetic resonance imaging or spectroscopy. The specific project is to use handgrip to detect the changes in high energy phosphate metabolism between rest and stress. Themore » high energy phosphates, ATP and phosphocreatine (PCr) are responsible for the energy of the heart muscle (myocardium) responsible for its contractile function. If the blood supply to the myocardium in insufficient to support metabolism and contractility during stress, the high energy phosphates, particularly PCr, will decrease in concentration. The high energy phosphates can be tracked using phosphorus-31 magnetic resonance spectroscopy ({sup 31}P MRS). In Project 2 the UAB Surgical Robotics project focuses on the use of virtual presence to assist with remote surgery and surgical training. The goal of this proposal was to assemble a pilot system for proof of concept. The pilot project was completed successfully and was judged to demonstrate that the concept of remote surgical assistance as applied to surgery and surgical training was feasible and warranted further development. The main objective of Project 3 is to develop a system to allow for the tele-robotic delivery of instrumentation during a functional neurosurgical procedure (Figure 3). Instrumentation such as micro-electrical recording probes or deep brain stimulation leads. Current methods for the delivery of these instruments involve the integration of linear actuators to stereotactic navigation systems. The control of these

  6. One-stage posterior focus debridement, interbody grafts, and posterior instrumentation and fusion in the surgical treatment of thoracolumbar spinal tuberculosis with kyphosis in children: a preliminary report.

    PubMed

    Wang, Yu-Xiang; Zhang, Hong-Qi; Tang, Ming-Xing; Guo, Chao-Feng; Deng, Ang; Wu, Jian-Huang; Liu, Jin-Yang; Deng, Zhansheng; Chen, Jing

    2016-08-01

    The purpose of this study was to determine the efficacy and feasibility of surgical management of children with thoracolumbar spine tuberculosis with kyphosis by using one-stage posterior focus debridement, interbody grafts, and posterior instrumentation and fusion. From October 2010 to September 2013, 21 children with thoracolumbar spinal tuberculosis accompanied by kyphosis were treated with one-stage posterior decompression, interbody grafts, and posterior instrumentation and fusion. There were 13 males and 8 females, aged from 7 to 13 years old (average age 9.9 years). The mean follow-up was 34 months (range26-48 months). Patients were evaluated before and after surgery in terms of ESR, neurologic status, pain, and kyphotic angle. Spinal tuberculosis was completely cured, and the grafted bones were fused in all 21 patients. There was no recurrent tuberculous infection. ESR got normal within 3 months in all patients. The ASIA neurologic classification improved in all cases. Pain relief was obtained in all patients. The average preoperative kyphosis was 29.7° (range 12-42°) and decreased to 5.5° (range 2-10°), postoperatively. There was no significant loss of the correction at the latest follow-up. Our results show that one-stage posterior decompression, interbody grafts, and posterior instrumentation and fusion were an effective treatment for children with thoracolumbar spinal tuberculosis. It is characterized as minimum surgical trauma, good neurologic recovery, good correction of kyphosis, and prevention of progressive kyphosis.

  7. ETS-VI multibeam satellite communications systems

    NASA Astrophysics Data System (ADS)

    Kawai, Makoto; Tanaka, Masayoshi; Ohtomo, Isao

    1989-10-01

    The fixed and mobile satellite communications systems of the Japanese Engineering Test Satellite-VI (ETS-VI) are described. The system requirements are outlined along with the system configuration. The ETS-VI multibeam system employs three frequency bands. When used for Ka-band fixed communications, it covers the Japanese main islands with thirteen 0.3-degree-wide spot beam. Four of the beams are active for ETS-VI. When used for S-band mobile communications, five beams cover the area within 200 nautical miles from the Japanese coast. The C-band beam for fixed communications covers the central area of the Japanese main islands with a single beam. The onboard antenna system is described along with the transponders and their associated onboard systems. A discussion of the system technology follows, covering the TDMA transmisssion system, the relay function, rainfall compensation, and the antenna and propagation performance.

  8. ViLLaGEs: opto-mechanical design of an on-sky visible-light MEMS-based AO system

    NASA Astrophysics Data System (ADS)

    Grigsby, Bryant; Lockwood, Chris; Baumann, Brian; Gavel, Don; Johnson, Jess; Ammons, S. Mark; Dillon, Daren; Morzinski, Katie; Reinig, Marc; Palmer, Dave; Severson, Scott; Gates, Elinor

    2008-07-01

    Visible Light Laser Guidestar Experiments (ViLLaGEs) is a new Micro-Electro Mechanical Systems (MEMS) based visible-wavelength adaptive optics (AO) testbed on the Nickel 1-meter telescope at Lick Observatory. Closed loop Natural Guide Star (NGS) experiments were successfully carried out during engineering during the fall of 2007. This is a major evolutionary step, signaling the movement of AO technologies into visible light with a MEMS mirror. With on-sky Strehls in I-band of greater than 20% during second light tests, the science possibilities have become evident. Described here is the advanced engineering used in the design and construction of the ViLLaGEs system, comparing it to the LickAO infrared system, and a discussion of Nickel dome infrastructural improvements necessary for this system. A significant portion of the engineering discussion revolves around the sizable effort that went towards eliminating flexure. Then, we detail upgrades to ViLLaGEs to make it a facility class instrument. These upgrades will focus on Nyquist sampling the diffraction limited point spread function during open loop operations, motorization and automation for technician level alignments, adding dithering capabilities and changes for near infrared science.

  9. Vi-da: vitiligo diagnostic assistance mobile application

    NASA Astrophysics Data System (ADS)

    Nugraha, G. A.; Nurhudatiana, A.; Bahana, R.

    2018-03-01

    Vitiligo is a skin disorder in which white patches of depigmentation appear on different parts of the body. Usually, patients come to hospitals or clinics to have their vitiligo conditions assessed. This can be very tiring to the patients, as vitiligo treatments usually take a relatively long period of time, which can range from months to years. To address this challenge, we present in this paper a prototype of an Android-based mobile application called Vi-DA, which stands for Vitiligo Diagnostic Assistance. Vi-DA consists of three subsystems, which are user sign-up subsystem, camera and image analysis subsystem, and progress report subsystem. The mobile application was developed in Java programming language and uses MySQL as the database system. Vi-DA adopts a vitiligo segmentation algorithm to segment input image into normal skin area, vitiligo skin area, and non-skin area. Results showed that Vi-DA gave comparable results to the previous system implemented in Matlab. User acceptance testing results also showed that all respondents agreed on the usefulness of the system and agreed to use Vi-DA again in the future. Vi-DA benefits both dermatologists and patients as not only a computer-aided diagnosis (CAD) tool but also as a smart application that can be used for self-assessment at home.

  10. Laser versus cold instruments for microlaryngoscopic surgery.

    PubMed

    Zeitels, S M

    1996-05-01

    Controversy has arisen concerning the merits of the CO2 laser in microlaryngoscopic surgery because of the potentially harmful effects that the injudicious application of the laser could have on voice production. In an effort to develop a logical approach to instrument selection, the author examined the use of both cold instruments and the CO2 laser in the treatment of various benign and malignant lesions. A retrospective review of 307 microlaryngeal procedures performed over a 3-year period revealed that 263 (86%) were glottal and 44 (14%) were supraglottal. Of the 263 glottal procedures, 203 (77%) employed cold instruments alone and 60 (23%) used both cold instruments and the CO2 laser. The laser was used to assist in all 44 supraglottal procedures. Therefore, 203 (66%) of 307 procedures were done with cold instruments alone, and 104 (34%) of 307 procedures were performed using the CO2 laser with cold instruments. Lesions were stratified on the basis of pathology and size, as well as surgical approach. A primary phonomicrosurgical principle in glottal surgery is to maximally preserve the vocal fold's layered microstructure (laminae propria and epithelium). Precise tangential dissection was necessary for achieving this goal. For limited lesions, this dissection was best accomplished with cold instruments alone. The CO2 laser facilitated hemostatic surgical dissection for all supraglottal lesions and for selected larger glottal lesions in which bleeding would obscure visualization of the microanatomy of the musculomembranous vocal fold.

  11. LabVIEW 2010 Computer Vision Platform Based Virtual Instrument and Its Application for Pitting Corrosion Study.

    PubMed

    Ramos, Rogelio; Zlatev, Roumen; Valdez, Benjamin; Stoytcheva, Margarita; Carrillo, Mónica; García, Juan-Francisco

    2013-01-01

    A virtual instrumentation (VI) system called VI localized corrosion image analyzer (LCIA) based on LabVIEW 2010 was developed allowing rapid automatic and subjective error-free determination of the pits number on large sized corroded specimens. The VI LCIA controls synchronously the digital microscope image taking and its analysis, finally resulting in a map file containing the coordinates of the detected probable pits containing zones on the investigated specimen. The pits area, traverse length, and density are also determined by the VI using binary large objects (blobs) analysis. The resulting map file can be used further by a scanning vibrating electrode technique (SVET) system for rapid (one pass) "true/false" SVET check of the probable zones only passing through the pit's centers avoiding thus the entire specimen scan. A complete SVET scan over the already proved "true" zones could determine the corrosion rate in any of the zones.

  12. [ANALYSIS OF THE SURGICAL TREATMENT RESULTS IN THE THYROID GLAND DISEASES].

    PubMed

    Tarashchenko, Yu N; Bolgov, M Yu

    2015-08-01

    The results of surgical treatment of the thyroid gland diseases were analyzed, including the specific morbidity rate, cosmetic effect of the operation, stationary treatment of patients duration, the operation radicalism. Improvement of the operation methods and introduction of modern electric surgical instruments have permitted to reduce the operation duration, the surgical access length, the rate of postoperative hypocalcaemia occurrence, duration of the patients stationary treatment.

  13. ViA: a perceptual visualization assistant

    NASA Astrophysics Data System (ADS)

    Healey, Chris G.; St. Amant, Robert; Elhaddad, Mahmoud S.

    2000-05-01

    This paper describes an automated visualized assistant called ViA. ViA is designed to help users construct perceptually optical visualizations to represent, explore, and analyze large, complex, multidimensional datasets. We have approached this problem by studying what is known about the control of human visual attention. By harnessing the low-level human visual system, we can support our dual goals of rapid and accurate visualization. Perceptual guidelines that we have built using psychophysical experiments form the basis for ViA. ViA uses modified mixed-initiative planning algorithms from artificial intelligence to search of perceptually optical data attribute to visual feature mappings. Our perceptual guidelines are integrated into evaluation engines that provide evaluation weights for a given data-feature mapping, and hints on how that mapping might be improved. ViA begins by asking users a set of simple questions about their dataset and the analysis tasks they want to perform. Answers to these questions are used in combination with the evaluation engines to identify and intelligently pursue promising data-feature mappings. The result is an automatically-generated set of mappings that are perceptually salient, but that also respect the context of the dataset and users' preferences about how they want to visualize their data.

  14. Cranial mononeuropathy VI

    MedlinePlus

    ... palsy; Cranial nerve VI palsy; Sixth nerve palsy; Neuropathy - sixth nerve ... with: Brain aneurysms Nerve damage from diabetes( diabetic neuropathy ) Gradenigo syndrome (which also causes discharge from the ...

  15. Uranium(VI) Reduction by Anaeromyxobacter dehalogenans Strain 2CP-C

    PubMed Central

    Wu, Qingzhong; Sanford, Robert A.; Löffler, Frank E.

    2006-01-01

    Previous studies demonstrated growth of Anaeromyxobacter dehalogenans strain 2CP-C with acetate or hydrogen as the electron donor and Fe(III), nitrate, nitrite, fumarate, oxygen, or ortho-substituted halophenols as electron acceptors. In this study, we explored and characterized U(VI) reduction by strain 2CP-C. Cell suspensions of fumarate-grown 2CP-C cells reduced U(VI) to U(IV). More-detailed growth studies demonstrated that hydrogen was the required electron donor for U(VI) reduction and could not be replaced by acetate. The addition of nitrate to U(VI)-reducing cultures resulted in a transitory increase in U(VI) concentration, apparently caused by the reoxidation of reduced U(IV), but U(VI) reduction resumed following the consumption of N-oxyanions. Inhibition of U(VI) reduction occurred in cultures amended with Fe(III) citrate, or citrate. In the presence of amorphous Fe(III) oxide, U(VI) reduction proceeded to completion but the U(VI) reduction rates decreased threefold compared to control cultures. Fumarate and 2-chlorophenol had no inhibitory effects on U(VI) reduction, and both electron acceptors were consumed concomitantly with U(VI). Since cocontaminants (e.g., nitrate, halogenated compounds) and bioavailable ferric iron are often encountered at uranium-impacted sites, the metabolic versatility makes Anaeromyxobacter dehalogenans a promising model organism for studying the complex interaction of multiple electron acceptors in U(VI) reduction and immobilization. PMID:16672509

  16. Investigation on Microbial Dissolution of Uranium (VI) from Autunite Mineral - 13421

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sepulveda, Paola; Katsenovich, Yelena; Lagos, Leonel

    2013-07-01

    Precipitating autunite minerals by polyphosphate injection was identified as a feasible remediation strategy for sequestering uranium in contaminated groundwater and soil in situ at the Hanford Site. Autunite stability under vadose and saturated zone environmental conditions can help to determine the long-term effectiveness of this remediation strategy. The Arthrobacter bacteria are one of the most common groups in soils and are found in large numbers in Hanford soil as well as other subsurface environments contaminated with radionuclides. Ubiquitous in subsurface microbial communities, these bacteria can play a significant role in the dissolution of minerals and the formation of secondary minerals.more » The main objective of this investigation was to study the bacterial interactions under oxidizing conditions with uranium (VI); study the potential role of bicarbonate, which is an integral complexing ligand for U(VI) and a major ion in groundwater compositions; and present data from autunite dissolution experiments using Arthrobacter strain G968, a less U(VI)-tolerant strain. Sterile 100 mL glass mixed reactors served as the major bioreactor for initial experimentation. These autunite-containing bioreactors were injected with bacterial cells after the autunite equilibrated with the media solution amended with 0 mM, 3 mM 5 mM and 10 mM concentrations of bicarbonate. G968 Arthrobacter cells in the amount of 10{sup 6} cells/mL were injected into the reactors after 27 days, giving time for the autunite to reach steady state. Abiotic non-carbonate controls were kept without bacterial inoculation to provide a control for the biotic samples. Samples of the solution were analyzed for dissolved U(VI) by means of kinetic phosphorescence analyzer KPA-11 (Chemcheck Instruments, Richland, WA). Analysis showed that as [HCO{sub 3}{sup -}] increases, a diminishing trend on the effect of bacteria on autunite leaching is observed. Viability of cells was conducted after 24 hours

  17. Compact teleoperated laparoendoscopic single-site robotic surgical system: Kinematics, control, and operation.

    PubMed

    Isaac-Lowry, Oran Jacob; Okamoto, Steele; Pedram, Sahba Aghajani; Woo, Russell; Berkelman, Peter

    2017-12-01

    To date a variety of teleoperated surgical robotic systems have been developed to improve a surgeon's ability to perform demanding single-port procedures. However typical large systems are bulky, expensive, and afford limited angular motion, while smaller designs suffer complications arising from limited motion range, speed, and force generation. This work was to develop and validate a simple, compact, low cost single site teleoperated laparoendoscopic surgical robotic system, with demonstrated capability to carry out basic surgical procedures. This system builds upon previous work done at the University of Hawaii at Manoa and includes instrument and endoscope manipulators as well as compact articulated instruments designed to overcome single incision geometry complications. A robotic endoscope holder was used for the base, with an added support frame for teleoperated manipulators and instruments fabricated mostly from 3D printed parts. Kinematics and control methods were formulated for the novel manipulator configuration. Trajectory following results from an optical motion tracker and sample task performance results are presented. Results indicate that the system has successfully met the goal of basic surgical functionality while minimizing physical size, complexity, and cost. Copyright © 2017 John Wiley & Sons, Ltd.

  18. Evidence-based management of deep wound infection after spinal instrumentation.

    PubMed

    Lall, Rishi R; Wong, Albert P; Lall, Rohan R; Lawton, Cort D; Smith, Zachary A; Dahdaleh, Nader S

    2015-02-01

    In this study, evidence-based medicine is used to assess optimal surgical and medical management of patients with post-operative deep wound infection following spinal instrumentation. A computerized literature search of the PubMed database was performed. Twenty pertinent studies were identified. Studies were separated into publications addressing instrumentation retention versus removal and publications addressing antibiotic therapy regimen. The findings were classified based on level of evidence (I-III) and findings were summarized into evidentiary tables. No level I or II evidence was identified. With regards to surgical management, five studies support instrumentation retention in the setting of early deep infection. In contrast, for delayed infection, the evidence favors removal of instrumentation at the time of initial debridement. Surgeons should be aware that for deformity patients, even if solid fusion is observed, removal of instrumentation may be associated with significant loss of correction. A course of intravenous antibiotics followed by long-term oral suppressive therapy should be pursued if instrumentation is retained. A shorter treatment course may be appropriate if hardware is removed. Copyright © 2014 Elsevier Ltd. All rights reserved.

  19. 23 CFR 200.7 - FHWA Title VI policy.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 23 Highways 1 2010-04-01 2010-04-01 false FHWA Title VI policy. 200.7 Section 200.7 Highways FEDERAL HIGHWAY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION CIVIL RIGHTS TITLE VI PROGRAM AND RELATED STATUTES-IMPLEMENTATION AND REVIEW PROCEDURES § 200.7 FHWA Title VI policy. It is the policy of the FHWA to...

  20. 23 CFR 200.7 - FHWA Title VI policy.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 23 Highways 1 2011-04-01 2011-04-01 false FHWA Title VI policy. 200.7 Section 200.7 Highways FEDERAL HIGHWAY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION CIVIL RIGHTS TITLE VI PROGRAM AND RELATED STATUTES-IMPLEMENTATION AND REVIEW PROCEDURES § 200.7 FHWA Title VI policy. It is the policy of the FHWA to...

  1. 23 CFR 200.7 - FHWA Title VI policy.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 23 Highways 1 2014-04-01 2014-04-01 false FHWA Title VI policy. 200.7 Section 200.7 Highways FEDERAL HIGHWAY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION CIVIL RIGHTS TITLE VI PROGRAM AND RELATED STATUTES-IMPLEMENTATION AND REVIEW PROCEDURES § 200.7 FHWA Title VI policy. It is the policy of the FHWA to...

  2. 23 CFR 200.7 - FHWA Title VI policy.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 23 Highways 1 2013-04-01 2013-04-01 false FHWA Title VI policy. 200.7 Section 200.7 Highways FEDERAL HIGHWAY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION CIVIL RIGHTS TITLE VI PROGRAM AND RELATED STATUTES-IMPLEMENTATION AND REVIEW PROCEDURES § 200.7 FHWA Title VI policy. It is the policy of the FHWA to...

  3. [Assessment of surgical competence. A Mexican pilot study].

    PubMed

    Anaya-Prado, Roberto; Ortega-León, Luis Humberto; Ramirez-Solis, Mauro Eduardo; Vázquez-García, José Arturo; Medina-Portillo, Juan Bernardo; Ayala-López, Ernesto Alonso

    2012-01-01

    Assessment of technical dexterity is currently the weakest issue in surgical evaluation. It is imperative to develop an objective exam that allows us to correct training deficiencies and abilities and to objectively feedback education programs and hospitals. The purpose of this study was to perform a correlation between theoretical knowledge and surgical skills. We performed a national pilot study in in surgeons certifying by the Mexican Board of Surgery in 2010. This was a two-stage study: written exam (stage I) and oral exam (viva voce) to all surgeons approving the written exam (stage II). In stage II we utilized an objective structured assessment of technical skills (OSATS) whose results were correlated with those of the written and oral exams. The assessment involved seven skill stations and a global rating scale to indicate correctly performed or not and a fail/pass exam, respectively. Sixty-two surgeons approved the written exam in two places. We found no statistical difference among skills in open surgery (bowel anastomosis, liver and vascular suture), laparoscopic surgery (grape pilling, cutting a circle and intracorporeal knot tying) and instrument identification. There was a statistically significant difference (p <0.001) when median values were compared between laparoscopic surgery vs. open surgery and the identification of surgical instruments. There was a correlation between theoretical knowledge and surgical skills. When applying an OSATS, we found a positive correlation between theoretical knowledge and surgical skills. This assessment proves to to be valid and reliable for the evaluation of surgical dexterity.

  4. Thermo Scientific Sulfur Dioxide Analyzer Instrument Handbook

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Springston, S. R.

    The Sulfur Dioxide Analyzer measures sulfur dioxide based on absorbance of UV light at one wavelength by SO2 molecules which then decay to a lower energy state by emitting UV light at a longer wavelength. Specifically, SO2 + hυ1 →SO2 *→SO2 + hυ2 The emitted light is proportional to the concentration of SO2 in the optical cell. External communication with the analyzer is available through an Ethernet port configured through the instrument network of the AOS systems. The Model 43i-TLE is part of the i-series of Thermo Scientific instruments. The i-series instruments are designed to interface with external computers throughmore » the proprietary Thermo Scientific iPort Software. However, this software is somewhat cumbersome and inflexible. BNL has written an interface program in National Instruments LabView that both controls the Model 43i-TLE Analyzer AND queries the unit for all measurement and housekeeping data. The LabView vi (the software program written by BNL) ingests all raw data from the instrument and outputs raw data files in a uniform data format similar to other instruments in the AOS and described more fully in Section 6.0 below.« less

  5. Association of a Surgical Task During Training With Team Skill Acquisition Among Surgical Residents: The Missing Piece in Multidisciplinary Team Training.

    PubMed

    Sparks, Jessica L; Crouch, Dustin L; Sobba, Kathryn; Evans, Douglas; Zhang, Jing; Johnson, James E; Saunders, Ian; Thomas, John; Bodin, Sarah; Tonidandel, Ashley; Carter, Jeff; Westcott, Carl; Martin, R Shayn; Hildreth, Amy

    2017-09-01

    The human patient simulators that are currently used in multidisciplinary operating room team training scenarios cannot simulate surgical tasks because they lack a realistic surgical anatomy. Thus, they eliminate the surgeon's primary task in the operating room. The surgical trainee is presented with a significant barrier when he or she attempts to suspend disbelief and engage in the scenario. To develop and test a simulation-based operating room team training strategy that challenges the communication abilities and teamwork competencies of surgeons while they are engaged in realistic operative maneuvers. This pre-post educational intervention pilot study compared the gains in teamwork skills for midlevel surgical residents at Wake Forest Baptist Medical Center after they participated in a standardized multidisciplinary team training scenario with 3 possible levels of surgical realism: (1) SimMan (Laerdal) (control group, no surgical anatomy); (2) "synthetic anatomy for surgical tasks" mannequin (medium-fidelity anatomy), and (3) a patient simulated by a deceased donor (high-fidelity anatomy). Participation in the simulation scenario and the subsequent debriefing. Teamwork competency was assessed using several instruments with extensive validity evidence, including the Nontechnical Skills assessment, the Trauma Management Skills scoring system, the Crisis Resource Management checklist, and a self-efficacy survey instrument. Participant satisfaction was assessed with a Likert-scale questionnaire. Scenario participants included midlevel surgical residents, anesthesia providers, scrub nurses, and circulating nurses. Statistical models showed that surgical residents exposed to medium-fidelity simulation (synthetic anatomy for surgical tasks) team training scenarios demonstrated greater gains in teamwork skills compared with control groups (SimMan) (Nontechnical Skills video score: 95% CI, 1.06-16.41; Trauma Management Skills video score: 95% CI, 0.61-2.90) and

  6. Replication profile of Saccharomyces cerevisiae chromosome VI.

    PubMed

    Friedman, K L; Brewer, B J; Fangman, W L

    1997-11-01

    An understanding of the replication programme at the genome level will require the identification and characterization of origins of replication through large, contiguous regions of DNA. As a step toward this goal, origin efficiencies and replication times were determined for 10 ARSs spanning most of the 270 kilobase (kb) chromosome VI of Saccharomyces cerevisiae. Chromosome VI shows a wide variation in the percentage of cell cycles in which different replication origins are utilized. Most of the origins are activated in only a fraction of cells, suggesting that the pattern of origin usage on chromosome VI varies greatly within the cell population. The replication times of fragments containing chromosome VI origins show a temporal pattern that has been recognized on other chromosomes--the telomeres replicate late in S phase, while the central region of the chromosome replicates early. As demonstrated here for chromosome VI, analysis of the direction of replication fork movement along a chromosome and determination of replication time by measuring a period of hemimethylation may provide an efficient means of surveying origin activity over large regions of the genome.

  7. 1. COMPARISON OF PLANS, SHOWING KONGENSGADE 6 (see photograph VI50 ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    1. COMPARISON OF PLANS, SHOWING KONGENSGADE 6 (see photograph VI-50 50-2 for elevation), KONGENSGADE 8 (see photograph VI-50-3 for elevation), KONGENSGADE 9 (see photograph VI-50-3 for elevation), KONGENSGADE 17 (see photograph VI-50-5 for elevation), KONGENSGADE 56 (see photograph VI-50-8 for elevation), & KONGENSGADE 57 (see photograph VI-50-9 for elevation) - King Street Area Study, Kongensgade 5-18, 36, 37B, 51-58 (Houses), 5-18, 36-37B, 51-58 King Street, Frederiksted, St. Croix, VI

  8. Minimally invasive surgical instruments with an accessory channel capable of integrating fibre-optic cable for optical biopsy: a review of the state of the art.

    PubMed

    Jelínek, Filip; Arkenbout, Ewout A; Sakes, Aimée; Breedveld, Paul

    2014-08-01

    This review article provides a comprehensive overview and classification of minimally invasive surgical instruments with an accessory channel incorporating fibreoptics or another auxiliary device for various purposes. More specifically, this review was performed with the focus on the newly emerging field of optical biopsy, its objective being to discuss primarily the instruments capable of carrying out the optical biopsy and subsequent tissue resection. Instruments housing the fibreoptics for other uses, as well as instruments with an accessory channel capable of housing the fibreoptics instead of their original auxiliary device after relevant design modifications, supplement the review. The entire Espacenet and Scopus databases were searched, yielding numerous patents and articles on conceptual and existing instruments satisfying the criteria. The instruments were categorised based on the function the fibreoptics or the auxiliary device serves. On the basis of their geometrical placement with respect to the tissue resector or manipulator, the subcategories were further defined. This subdivision was used to identify the feasibility of performing the optical biopsy and the tissue resection in an accurate and successive fashion. In general, the existing concepts or instruments are regarded as limited with regard to such a functionality, either due to the placement of their accessory channel with or without the fibreoptics or due to the operational restrictions of their tissue manipulators. A novel opto-mechanical biopsy harvester, currently under development at Delft University of Technology, is suggested as a promising alternative, ensuring a fast and accurate succession of the optical and the mechanical biopsies of a flat superficial tissue. © IMechE 2014.

  9. 29 CFR 1915.1026 - Chromium (VI).

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... present from skin or eye contact with chromium (VI), the employer shall provide appropriate personal... clothing and equipment should be laundered or cleaned in a manner that minimizes skin or eye contact with... shall provide change rooms in conformance with 29 CFR 1910.141. Where skin contact with chromium (VI...

  10. Characterization of Amoeba proteus myosin VI immunoanalog.

    PubMed

    Dominik, Magdalena; Kłopocka, Wanda; Pomorski, Paweł; Kocik, Elzbieta; Redowicz, Maria Jolanta

    2005-07-01

    Amoeba proteus, the highly motile free-living unicellular organism, has been widely used as a model to study cell motility. However, molecular mechanisms underlying its unique locomotion and intracellular actin-based-only trafficking remain poorly understood. A search for myosin motors responsible for vesicular transport in these giant cells resulted in detection of 130-kDa protein interacting with several polyclonal antibodies against different tail regions of human and chicken myosin VI. This protein was binding to actin in the ATP-dependent manner, and immunoprecipitated with anti-myosin VI antibodies. In order to characterize its possible functions in vivo, its cellular distribution and colocalization with actin filaments and dynamin II during migration and pinocytosis were examined. In migrating amoebae, myosin VI immunoanalog localized to vesicular structures, particularly within the perinuclear and sub-plasma membrane areas, and colocalized with dynamin II immunoanalog and actin filaments. The colocalization was even more evident in pinocytotic cells as proteins concentrated within pinocytotic pseudopodia. Moreover, dynamin II and myosin VI immunoanalogs cosedimented with actin filaments, and were found on the same isolated vesicles. Blocking endogenous myosin VI immunoanalog with anti-myosin VI antibodies inhibited the rate of pseudopodia protrusion (about 19% decrease) and uroidal retraction (about 28% decrease) but did not affect cell morphology and the manner of cell migration. Treatment with anti-human dynamin II antibodies led to changes in directionality of amebae migration and affected the rate of only uroidal translocation (about 30% inhibition). These results indicate that myosin VI immunoanalog is expressed in protist Amoeba proteus and may be involved in vesicle translocation and cell locomotion.

  11. Measuring the Quality of Life of Visually Impaired Children: First Stage Psychometric Evaluation of the Novel VQoL_CYP Instrument.

    PubMed

    Tadić, Valerija; Cooper, Andrew; Cumberland, Phillippa; Lewando-Hundt, Gillian; Rahi, Jugnoo S

    2016-01-01

    To report piloting and initial validation of the VQoL_CYP, a novel age-appropriate vision-related quality of life (VQoL) instrument for self-reporting by children with visual impairment (VI). Participants were a random patient sample of children with VI aged 10-15 years. 69 patients, drawn from patient databases at Great Ormond Street Hospital and Moorfields Eye Hospital, United Kingdom, participated in piloting of the draft 47-item VQoL instrument, which enabled preliminary item reduction. Subsequent administration of the instrument, alongside functional vision (FV) and generic health-related quality of life (HRQoL) self-report measures, to 101 children with VI comprising a nationally representative sample enabled further item reduction and evaluation of psychometric properties using Rasch analysis. Construct validity was assessed through Pearson correlation coefficients. Item reduction through piloting (8 items removed for skewness and individual item response pattern) and validation (1 item removed for skewness and 3 for misfit in Rasch) produced a 35-item scale, with fit values within acceptable limits, no notable differential item functioning, good measurement precision, ordered response categories and acceptable targeting in Rasch. The VQoL_CYP showed good construct validity, correlating strongly with HRQoL scores, moderately with FV scores but not with acuity. Robust child-appropriate self-report VQoL measures for children with VI are necessary for understanding the broader impacts of living with a visual disability, distinguishing these from limited functioning per se. Future planned use in larger patient samples will allow further psychometric development of the VQoL_CYP as an adjunct to objective outcomes assessment.

  12. ViDI: Virtual Diagnostics Interface. Volume 1; The Future of Wind Tunnel Testing

    NASA Technical Reports Server (NTRS)

    Fleming, Gary A. (Technical Monitor); Schwartz, Richard J.

    2004-01-01

    The quality of data acquired in a given test facility ultimately resides within the fidelity and implementation of the instrumentation systems. Over the last decade, the emergence of robust optical techniques has vastly expanded the envelope of measurement possibilities. At the same time the capabilities for data processing, data archiving and data visualization required to extract the highest level of knowledge from these global, on and off body measurement techniques have equally expanded. Yet today, while the instrumentation has matured to the production stage, an optimized solution for gaining knowledge from the gigabytes of data acquired per test (or even per test point) is lacking. A technological void has to be filled in order to possess a mechanism for near-real time knowledge extraction during wind tunnel experiments. Under these auspices, the Virtual Diagnostics Interface, or ViDI, was developed.

  13. Virtual Instrumentation Corrosion Controller for Natural Gas Pipelines

    NASA Astrophysics Data System (ADS)

    Gopalakrishnan, J.; Agnihotri, G.; Deshpande, D. M.

    2012-12-01

    Corrosion is an electrochemical process. Corrosion in natural gas (methane) pipelines leads to leakages. Corrosion occurs when anode and cathode are connected through electrolyte. Rate of corrosion in metallic pipeline can be controlled by impressing current to it and thereby making it to act as cathode of corrosion cell. Technologically advanced and energy efficient corrosion controller is required to protect natural gas pipelines. Proposed virtual instrumentation (VI) based corrosion controller precisely controls the external corrosion in underground metallic pipelines, enhances its life and ensures safety. Designing and development of proportional-integral-differential (PID) corrosion controller using VI (LabVIEW) is carried out. When the designed controller is deployed at field, it maintains the pipe to soil potential (PSP) within safe operating limit and not entering into over/under protection zone. Horizontal deployment of this technique can be done to protect all metallic structure, oil pipelines, which need corrosion protection.

  14. LabVIEW 2010 Computer Vision Platform Based Virtual Instrument and Its Application for Pitting Corrosion Study

    PubMed Central

    Ramos, Rogelio; Zlatev, Roumen; Valdez, Benjamin; Stoytcheva, Margarita; Carrillo, Mónica; García, Juan-Francisco

    2013-01-01

    A virtual instrumentation (VI) system called VI localized corrosion image analyzer (LCIA) based on LabVIEW 2010 was developed allowing rapid automatic and subjective error-free determination of the pits number on large sized corroded specimens. The VI LCIA controls synchronously the digital microscope image taking and its analysis, finally resulting in a map file containing the coordinates of the detected probable pits containing zones on the investigated specimen. The pits area, traverse length, and density are also determined by the VI using binary large objects (blobs) analysis. The resulting map file can be used further by a scanning vibrating electrode technique (SVET) system for rapid (one pass) “true/false” SVET check of the probable zones only passing through the pit's centers avoiding thus the entire specimen scan. A complete SVET scan over the already proved “true” zones could determine the corrosion rate in any of the zones. PMID:23691434

  15. 40 CFR Appendix Vi to Part 266 - Stack Plume Rise

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 27 2011-07-01 2011-07-01 false Stack Plume Rise VI Appendix VI to Part 266 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED... FACILITIES Pt. 266, App. VI Appendix VI to Part 266—Stack Plume Rise [Estimated Plume Rise (in Meters) Based...

  16. 19 CFR Annex Vi to Part 351 - Countervailing Investigations Timeline

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 19 Customs Duties 3 2010-04-01 2010-04-01 false Countervailing Investigations Timeline VI Annex VI to Part 351 Customs Duties INTERNATIONAL TRADE ADMINISTRATION, DEPARTMENT OF COMMERCE ANTIDUMPING AND COUNTERVAILING DUTIES Pt. 351, Annex VI Annex VI to Part 351—Countervailing Investigations Timeline ER19MY97.000 ...

  17. 19 CFR Annex Vi to Part 351 - Countervailing Investigations Timeline

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 19 Customs Duties 3 2013-04-01 2013-04-01 false Countervailing Investigations Timeline VI Annex VI to Part 351 Customs Duties INTERNATIONAL TRADE ADMINISTRATION, DEPARTMENT OF COMMERCE ANTIDUMPING AND COUNTERVAILING DUTIES Pt. 351, Annex VI Annex VI to Part 351—Countervailing Investigations Timeline ER19MY97.000 ...

  18. 19 CFR Annex Vi to Part 351 - Countervailing Investigations Timeline

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 19 Customs Duties 3 2014-04-01 2014-04-01 false Countervailing Investigations Timeline VI Annex VI to Part 351 Customs Duties INTERNATIONAL TRADE ADMINISTRATION, DEPARTMENT OF COMMERCE ANTIDUMPING AND COUNTERVAILING DUTIES Pt. 351, Annex VI Annex VI to Part 351—Countervailing Investigations Timeline ER19MY97.000 ...

  19. 19 CFR Annex Vi to Part 351 - Countervailing Investigations Timeline

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 19 Customs Duties 3 2012-04-01 2012-04-01 false Countervailing Investigations Timeline VI Annex VI to Part 351 Customs Duties INTERNATIONAL TRADE ADMINISTRATION, DEPARTMENT OF COMMERCE ANTIDUMPING AND COUNTERVAILING DUTIES Pt. 351, Annex VI Annex VI to Part 351—Countervailing Investigations Timeline ER19MY97.000 ...

  20. 19 CFR Annex Vi to Part 351 - Countervailing Investigations Timeline

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 19 Customs Duties 3 2011-04-01 2011-04-01 false Countervailing Investigations Timeline VI Annex VI to Part 351 Customs Duties INTERNATIONAL TRADE ADMINISTRATION, DEPARTMENT OF COMMERCE ANTIDUMPING AND COUNTERVAILING DUTIES Pt. 351, Annex VI Annex VI to Part 351—Countervailing Investigations Timeline ER19MY97.000 ...

  1. 40 CFR Appendix Vi to Part 266 - Stack Plume Rise

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 26 2010-07-01 2010-07-01 false Stack Plume Rise VI Appendix VI to Part 266 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED... FACILITIES Pt. 266, App. VI Appendix VI to Part 266—Stack Plume Rise [Estimated Plume Rise (in Meters) Based...

  2. Load evaluation of the da Vinci surgical system for transoral robotic surgery.

    PubMed

    Fujiwara, Kazunori; Fukuhara, Takahiro; Niimi, Koji; Sato, Takahiro; Kitano, Hiroya

    2015-12-01

    Transoral robotic surgery, performed with the da Vinci surgical system (da Vinci), is a surgical approach for benign and malignant lesions of the oral cavity and laryngopharynx. It provides several unique advantages, which include a 3-dimensional magnified view and ability to see and work around curves or angles. However, the current da Vinci surgical system does not provide haptic feedback. This is problematic because the potential risks specific to the transoral use of the da Vinci include tooth injury, mucosal laceration, ocular injury and mandibular fracture. To assess the potential for intraoperative injuries, we measured the load of the endoscope and the instrument of the da Vinci Si surgical system. We pressed the endoscope and instrument of the da Vinci Si against Load cell six times each and measured the dynamic load and the time-to-maximum load. We also struck the da Vinci Si endoscope and instrument against the Load cell six times each and measured the impact load. The maximum dynamic load was 7.27 ± 1.31 kg for the endoscope and 1.90 ± 0.72 for the instrument. The corresponding time-to-maximum loads were 1.72 ± 0.22 and 1.29 ± 0.34 s, but the impact loads were significantly lower than the dynamic load. It remains possible that a major load is exerted on adjacent structures by continuous contact with the endoscope and instrument of da Vinci Si. However, there is a minor delay in reaching the maximum load. Careful monitoring by an on-site assistant may, therefore, help prevent contiguous injury.

  3. Instrumentation For The Surgical Application Of The Nd:YAG Laser

    NASA Astrophysics Data System (ADS)

    Frank, F.; Bailer, P.; Beck, O.; Bowering, R.; Hofstetter, A.

    1984-03-01

    The Nd:YAG laser has become a coagulation instrument, which has found acceptance in interdisciplinary surgery. The main contributors are its highly efficient coagulation capability in interaction with tissue and the fact that the Nd:YAG laser beam can be transmitted by means of a simple quartz-glass fiber. Appropriate systems and instruments for transmission and operation have been developed for the various applications in neurosurgery, pulmology, gastroenterology, urology, gynaecology and dermatology. Operation methods in open and endoscopic surgery under use of several hand held devices and flexible as well as rigid endoscopes are being demonstrated by clinical examples of application.

  4. Three-Dimensional Printing Surgical Applications.

    PubMed

    AlAli, Ahmad B; Griffin, Michelle F; Butler, Peter E

    2015-01-01

    Three-dimensional printing, a technology used for decades in the industrial field, gains a lot of attention in the medical field for its potential benefits. With advancement of desktop printers, this technology is accessible and a lot of research is going on in the medical field. To evaluate its application in surgical field, which may include but not limited to surgical planning, surgical education, implants, and prosthesis, which are the focus of this review. Research was conducted by searching PubMed, Web of science, and other reliable sources. We included original articles and excluded articles based on animals, those more than 10 years old, and those not in English. These articles were evaluated, and relevant studies were included in this review. Three-dimensional printing shows a potential benefit in surgical application. Printed implants were used in patient in a few cases and show successful results; however, longer follow-up and more trials are needed. Surgical and medical education is believed to be more efficient with this technology than the current practice. Printed surgical instrument and surgical planning are also believed to improve with three-dimensional printing. Three-dimensional printing can be a very powerful tool in the near future, which can aid the medical field that is facing a lot of challenges and obstacles. However, despite the reported results, further research on larger samples and analytical measurements should be conducted to ensure this technology's impact on the practice.

  5. Three-Dimensional Printing Surgical Applications

    PubMed Central

    Griffin, Michelle F.; Butler, Peter E.

    2015-01-01

    Introduction: Three-dimensional printing, a technology used for decades in the industrial field, gains a lot of attention in the medical field for its potential benefits. With advancement of desktop printers, this technology is accessible and a lot of research is going on in the medical field. Objective: To evaluate its application in surgical field, which may include but not limited to surgical planning, surgical education, implants, and prosthesis, which are the focus of this review. Methods: Research was conducted by searching PubMed, Web of science, and other reliable sources. We included original articles and excluded articles based on animals, those more than 10 years old, and those not in English. These articles were evaluated, and relevant studies were included in this review. Discussion: Three-dimensional printing shows a potential benefit in surgical application. Printed implants were used in patient in a few cases and show successful results; however, longer follow-up and more trials are needed. Surgical and medical education is believed to be more efficient with this technology than the current practice. Printed surgical instrument and surgical planning are also believed to improve with three-dimensional printing. Conclusion: Three-dimensional printing can be a very powerful tool in the near future, which can aid the medical field that is facing a lot of challenges and obstacles. However, despite the reported results, further research on larger samples and analytical measurements should be conducted to ensure this technology's impact on the practice. PMID:26301002

  6. [Surgical smoke: risks and preventive measures].

    PubMed

    Carbajo-Rodríguez, Hilario; Aguayo-Albasini, José Luis; Soria-Aledo, Víctor; García-López, Concepción

    2009-05-01

    The application of the advanced technologies in medicine has led to the appearance of new risk factors for health personnel. One of these could be the surgical smoke produced by electrosurgical instruments, ultrasounds or laser. However, there is still insufficient evidence in the published population studies on the detrimental effects of chronic exposure to surgical smoke. The main concern on the possible damage to the health of operating room staff is mainly based on the components currently detected until the date and laboratory experiments. Caution must also be used when extrapolating the results of in vitro studies to daily clinical practice. The organisations responsible for protecting the health of the workers in different countries have still not issued guidelines for the treatment and removal of the surgical smoke generated in both open and laparoscopic procedures. In this article we try to present a view of the consequences that surgical smoke has on health and the preventive measures that can be adopted.

  7. Dynamics of Chromium(VI) Removal from Drinking Water by Iron Electrocoagulation.

    PubMed

    Pan, Chao; Troyer, Lyndsay D; Catalano, Jeffrey G; Giammar, Daniel E

    2016-12-20

    The potential for new U.S. regulations for Cr(VI) in drinking water have spurred strong interests in improving technologies for Cr(VI) removal. This study examined iron electrocoagulation for Cr(VI) removal at conditions directly relevant to drinking water treatment. Cr(VI) is chemically reduced to less soluble Cr(III) species by the Fe(II) produced from an iron anode, and XANES spectra indicate that the Cr is entirely Cr(III) in solid-phases produced in electrocoagulation. The dynamics of Cr(VI) removal in electrocoagulation at pH 6 and pH 8 at both oxic and anoxic conditions can be described by a new model that incorporates Fe(II) release from the anode and heterogeneous and homogeneous reduction of Cr(VI) by Fe(II). Heterogeneous Cr(VI) reduction by adsorbed Fe(II) was critical to interpreting Cr(VI) removal at pH 6, and the Fe- and Cr-containing EC product was found to catalyze the redox reaction. Dissolved oxygen (DO) did not observably inhibit Cr(VI) removal because Fe(II) reacts with DO more slowly than it does with Cr(VI), and Cr(VI) removal was faster at higher pH. Even in the presence of common groundwater solutes, iron electrocoagulation lowered Cr(VI) concentrations to levels well below California's 10 μg/L.

  8. 21 CFR 874.4420 - Ear, nose, and throat manual surgical instrument.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... device includes the esophageal dilator; tracheal bistour (a long, narrow surgical knife); tracheal dilator; tracheal hook; laryngeal injection set; laryngeal knife; laryngeal saw; laryngeal trocar...; wire ear loop; microrule; mirror; mobilizer; ear, nose, and throat punch; ear, nose and throat knife...

  9. Postoperative Surgical Infection After Spinal Surgery in Rheumatoid Arthritis.

    PubMed

    Koyama, Kensuke; Ohba, Tetsuro; Ebata, Shigeto; Haro, Hirotaka

    2016-05-01

    Individuals with rheumatoid arthritis are at higher risk for infection than the general population, and surgical site infection after spinal surgery in this population can result in clinically significant complications. The goal of this study was to identify risk factors for acute surgical site infection after spinal surgery in patients with rheumatoid arthritis who were treated with nonbiologic (conventional) disease-modifying antirheumatic drugs (DMARDs) alone or with biologic DMARDs. All patients treated with biologic agents were treated with nonbiologic agents as well. The authors performed a retrospective, single-center review of 47 consecutive patients with rheumatoid arthritis who underwent spinal surgery and had follow-up of 3 months or longer. The incidence of surgical site infection was examined, and multivariate logistic regression analysis was performed to test the association of surgical site infection with putative risk factors, including the use of biologic agents, methotrexate, and prednisolone, as well as the duration of rheumatoid arthritis, the presence of diabetes, patient age, length of surgery, and number of operative levels. After spinal surgery, 14.89% (7 of 47) of patients had surgical site infection. Use of methotrexate and/or prednisolone, patient age, diabetes, duration of rheumatoid arthritis, length of surgery, number of operative levels, and use of biologic DMARDs did not significantly increase the risk of infection associated with spinal surgery. All patients who had surgical site infection had undergone spinal surgery with instrumentation. The findings show that greater attention to preventing surgical site infection may be needed in patients with rheumatoid arthritis who undergo spinal surgery with instrumentation. To the authors' knowledge, this is the first study to show that the use of biologic agents did not increase the incidence of surgical site infection after spinal surgery in patients with rheumatoid arthritis

  10. Fluid handling 2: Surgical applications

    NASA Technical Reports Server (NTRS)

    Billica, Roger; Young, John; Rushing, Doug; Kizzee, Victor D.

    1991-01-01

    The methods proposed for managing fluids and particulate debris during minor surgery on Space Station Freedom (SSF) were investigated and demonstrated. A KC-135 parabolic flight test was performed, in which the flight followed the standard 40 parabola profile with 20 to 25 seconds in near-zero gravity in each parabola. The equipment (suction and laminar flow device) was evaluated. While this equipment performed satisfactorily previously in the dental simulation, the purpose of the current flight was to reconfigure the equipment in support of a minor surgical situation in order to evaluate its efficacy and establish clear requirements for the actual flight hardware. To accomplish the study the Health Maintenance Facility medical restraint system was deployed as for surgical use and mannequin suture arm was restrained to its surface. The surgical area was established as for performing minor surgery with standard tray and suture instruments employed.

  11. Kinetics of microbial reduction of Solid phase U(VI).

    PubMed

    Liu, Chongxuan; Jeon, Byong-Hun; Zachara, John M; Wang, Zheming; Dohnalkova, Alice; Fredrickson, James K

    2006-10-15

    Sodium boltwoodite (NaUO2SiO3OH x 1.5 H2O) was used to assess the kinetics of microbial reduction of solid-phase U(VI) by a dissimilatory metal-reducing bacterium (DMRB), Shewanella oneidensis strain MR-1. The bioreduction kinetics was studied with Na-boltwoodite in suspension or within alginate beads in a nongrowth medium with lactate as electron donor at pH 6.8 buffered with PIPES. Concentrations of U(VI)tot and cell number were varied to evaluate the coupling of U(VI) dissolution, diffusion, and microbial activity. Microscopic and spectroscopic analyses with transmission electron microscopy (TEM), energy dispersive spectroscopy (EDS), and laser-induced fluorescence spectroscopy (LIFS) collectively indicated that solid-phase U(VI) was first dissolved and diffused out of grain interiors before it was reduced on bacterial surfaces and/or within the periplasm. The kinetics of solid-phase U(VI) bioreduction was well described by a coupled model of bicarbonate-promoted dissolution of Na-boltwoodite, intragrain uranyl diffusion, and Monod type bioreduction kinetics with respect to dissolved U(VI) concentration. The results demonstrated that microbial reduction of solid-phase U(VI) is controlled by coupled biological, chemical, and physical processes.

  12. [The clinical analysis of instrumentation failure after corrective surgery for thoracolumbar focal kyphosis].

    PubMed

    Zeng, Y; Chen, Z Q; Qi, Q; Guo, Z Q; Li, W W; Sun, C G; Zhong, W Q; Jiang, Y

    2016-07-01

    To analyze the etiology of instrumentation failure after corrective surgery for thoracolumbar focal kyphosis, and make suggestion for treatment. Retrospective study for 8 patients with thoracolumbar focal kyphosis who underwent surgical treatment and suffered instrumentation failure from June 2005 to December 2011 was made. The surgical procedures included pedicle subtraction osteotomy (PSO), anterior opening-posterior closing osteotomy and correction (AOPC), and posterior vertebral column resection (VCR). The reasons of instrumentation failure were analyzed and revision surgeries were performed. The incidence of instrumentation failure was 6.3%. The average occurrence time was 22.5 months after surgery. Except one had failure in 3 months after surgery, all cases happened after 1 year. In this series, there were 5 cases with post-tuberculosis, 2 cases with post-traumatic kyphosis and 1 case with congenital kyphosis. For the surgical procedure, 7 cases underwent VCR and 1 case AOPC. After the instrumentation failure, all cases had back pain, and 3 of them had combined neurological symptoms. The reasons or risk factors of instrumentation failure included non-fusion of bone graft, VCR procedure, sink of the titanium mesh, insufficiency of anchor sites, and more severe kyphosis. All the 8 cases were treated with revision surgery and got good results. The instrumentation failure of thoracolumbar focal kyphosis is relatively late occurred, and can develop with various reasons. Positive revision surgery is suggested for the instrumentation failure, and good results can be expected.

  13. Simultaneous analysis of Cr(III), Cr(VI), and chromium picolinate in foods using capillary electrophoresis-inductively coupled plasma mass spectrometry.

    PubMed

    Chen, YiQuan; Chen, JinFa; Xi, Zhiming; Yang, Guidi; Wu, Zujian; Li, JianRong; Fu, FengFu

    2015-05-01

    We herein reported a method for the simultaneous detection of trace Cr(VI), Cr(III), and chromium(III) picolinate (CrPic) in foods using CE-ICP-MS together with ultrasonic-assisted extraction. The Cr(III) (Cr(3+) ) was chelated with trans-1,2-diaminocyclohexane-N,N,N´,N´-tetraacetic acid (DCTA) to form a single charged Cr-DCTA(-) complex. Then, Cr(VI) (CrO4 (2-) ), Cr-DCTA(-) , and CrPic were separated by CE within 8 min under a separation voltage of -13 KV followed by their monitoring with ICP mass spectrometer (ICP-MS). The proposed method is simple, effective, and sensitive. It has an instrument detection limit of 0.10, 0.18, and 0.20 ngCr/mL for Cr(VI), Cr(III), and CrPic, respectively. With the help of the methods, we have successfully determined Cr(VI), Cr(III), and CrPic in nutritional supplement (CrPic yeast tablet) with an RSD (n = 5) <6% and a recovery of 93-103%. The experimental results showed that CrPic was the main speciation of chromium in the nutritional supplement, with a concentration of 1514.6 μg Cr/g. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Influence of calcium on microbial reduction of solid phase uranium(VI).

    PubMed

    Liu, Chongxuan; Jeon, Byong-Hun; Zachara, John M; Wang, Zheming

    2007-08-15

    The effect of calcium on the dissolution and microbial reduction of a representative solid phase uranyl [U(VI)], sodium boltwoodite (NaUO(2)SiO(3)OH . 1.5H(2)O), was investigated to evaluate the rate-limiting step of microbial reduction of the solid phase U(VI). Microbial reduction experiments were performed in a culture of a dissimilatory metal-reducing bacterium (DMRB), Shewanella oneidensis strain MR-1, in a bicarbonate medium with lactate as electron donor at pH 6.8 buffered with PIPES. Calcium increased the rate of Na-boltwoodite dissolution and U(VI) bioavailability by increasing its solubility through the formation of a ternary aqueous calcium-uranyl-carbonate species. The ternary species, however, decreased the rates of microbial reduction of aqueous U(VI). Laser-induced fluorescence spectroscopy (LIFS) and transmission electron microscopy (TEM) collectively revealed that microbial reduction of solid phase U(VI) was a sequentially coupled process of Na-boltwoodite dissolution, U(VI) aqueous speciation, and microbial reduction of dissolved U(VI) to U(IV) that accumulated on bacterial surfaces/periplasm. Under studied experimental conditions, the overall rate of microbial reduction of solid phase U(VI) was limited by U(VI) dissolution reactions in solutions without calcium and limited by microbial reduction in solutions with calcium. Generally, the overall rate of microbial reduction of solid phase U(VI) was determined by the coupling of solid phase U(VI) dissolution, U(VI) aqueous speciation, and microbial reduction of dissolved U(VI) that were all affected by calcium. (c) 2007 Wiley Periodicals, Inc.

  15. The impact of the use of different types of gloves and bare hands for preparation of clean surgical instruments.

    PubMed

    Bruna, Camila Quartim de Moraes; Souza, Rafael Queiroz de; Massaia, Irineu Francisco Silva; Cruz, Áurea Silveira; Graziano, Kazuko Uchikawa

    2016-10-10

    to determine if there are differences on the safety of the preparation of clean surgical instruments using different types of gloves and bare hands and evaluate the microbiological load of these preparations without gloves. laboratory procedure with a pragmatic approach, in which the samples were handled with different types of gloves and bare hands. In addition, cytotoxicity assays were carried out by means of the agar diffusion method. Further samples were subjected to microbiological analysis after being handled without gloves. none of the samples showed cytotoxic effect. All microbiological cultures showed growth of microorganisms, but no microorganism has been recovered after autoclaving. there were no differences in the cytotoxic responses regarding the use of different types of gloves and bare hands in the handling of clean surgical instruments, which could entail iatrogenic risk. It is noteworthy that the use of gloves involves increase in the costs of process and waste generation, and the potential allergenic risk to latex. determinar se existe diferenças na segurança do preparo de instrumentais cirúrgicos relacionada ao uso de distintos tipos de luvas e das mãos nuas no preparo, e avaliar a carga microbiológica destes preparados sem luvas. experimento laboratorial com abordagem pragmática, onde amostras foram manipuladas com diferentes tipos de luvas e com as mãos nuas, elaborado teste de citotoxicidade por meio da difusão em ágar. Outras Amostras sofreram análise microbiológica após serem manipuladas sem luvas. nenhuma das amostras apresentou efeito citotóxico. Todas as culturas microbiológicas apresentaram crescimento de microrganismos, embora nenhum microrganismo tenha sido recuperado após a autoclavação. não houve diferenças nas respostas citotóxicas relacionadas ao uso de diferentes tipos de luvas e das mãos nuas na manipulação do instrumental cirúrgico limpo que sinalizasse risco de iatrogenia. Ressalta-se que o uso de luvas

  16. 40 CFR Appendixes Vi-Vii to Part 600 - [Reserved

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 29 2010-07-01 2010-07-01 false [Reserved] VI Appendixes VI-VII to Part 600 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY AND CARBON-RELATED EXHAUST EMISSIONS OF MOTOR VEHICLES Appendixes VI-VII to Part 600 [Reserved] ...

  17. 40 CFR Appendixes Vi-Vii to Part 600 - [Reserved

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 30 2011-07-01 2011-07-01 false [Reserved] VI Appendixes VI-VII to Part 600 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY AND CARBON-RELATED EXHAUST EMISSIONS OF MOTOR VEHICLES Appendixes VI-VII to Part 600 [Reserved] ...

  18. Lack of Collagen VI Promotes Wound-Induced Hair Growth.

    PubMed

    Chen, Peiwen; Cescon, Matilde; Bonaldo, Paolo

    2015-10-01

    Collagen VI is an extracellular matrix molecule that is abundantly expressed in the skin. However, the role of collagen VI in hair follicle growth is unknown. Here, we show that collagen VI is strongly deposited in hair follicles, and is markedly upregulated by skin wounding. Lack of collagen VI in Col6a1(-/-) mice delays hair cycling and growth under physiological conditions, but promotes wound-induced hair regrowth without affecting skin regeneration. Conversely, addition of purified collagen VI rescues the abnormal wound-induced hair regrowth in Col6a1(-/-) mice. Mechanistic studies revealed that the increased wound-induced hair regrowth of Col6a1(-/-) mice is triggered by activation of the Wnt/β-catenin signaling pathway, and is abolished by inhibition of this pathway. These findings highlight the essential relationships between extracellular matrix (ECM) and hair follicle regeneration, and suggest that collagen VI could be a potential therapeutic target for hair loss and other skin-related diseases.

  19. Robotic Surgical Training in an Academic Institution

    PubMed Central

    Chitwood, W. Randolph; Nifong, L. Wiley; Chapman, William H. H.; Felger, Jason E.; Bailey, B. Marcus; Ballint, Tara; Mendleson, Kim G.; Kim, Victor B.; Young, James A.; Albrecht, Robert A.

    2001-01-01

    Objective To detail robotic procedure development and clinical applications for mitral valve, biliary, and gastric reflux operations, and to implement a multispecialty robotic surgery training curriculum for both surgeons and surgical teams. Summary Background Data Remote, accurate telemanipulation of intracavitary instruments by general and cardiac surgeons is now possible. Complex technologic advancements in surgical robotics require well-designed training programs. Moreover, efficient robotic surgical procedures must be developed methodically and safely implemented clinically. Methods Advanced training on robotic systems provides surgeon confidence when operating in tiny intracavitary spaces. Three-dimensional vision and articulated instrument control are essential. The authors’ two da Vinci robotic systems have been dedicated to procedure development, clinical surgery, and training of surgical specialists. Their center has been the first United States site to train surgeons formally in clinical robotics. Results Established surgeons and residents have been trained using a defined robotic surgical educational curriculum. Also, 30 multispecialty teams have been trained in robotic mechanics and electronics. Initially, robotic procedures were developed experimentally and are described. In the past year the authors have performed 52 robotic-assisted clinical operations: 18 mitral valve repairs, 20 cholecystectomies, and 14 Nissen fundoplications. These respective operations required 108, 28, and 73 minutes of robotic telemanipulation to complete. Procedure times for the last half of the abdominal operations decreased significantly, as did the knot-tying time in mitral operations. There have been no deaths and few complications. One mitral patient had postoperative bleeding. Conclusion Robotic surgery can be performed safely with excellent results. The authors have developed an effective curriculum for training teams in robotic surgery. After training, surgeons

  20. Planck 2013 results. VI. High Frequency Instrument data processing

    NASA Astrophysics Data System (ADS)

    Planck Collaboration; Ade, P. A. R.; Aghanim, N.; Armitage-Caplan, C.; Arnaud, M.; Ashdown, M.; Atrio-Barandela, F.; Aumont, J.; Baccigalupi, C.; Banday, A. J.; Barreiro, R. B.; Battaner, E.; Benabed, K.; Benoît, A.; Benoit-Lévy, A.; Bernard, J.-P.; Bersanelli, M.; Bielewicz, P.; Bobin, J.; Bock, J. J.; Bond, J. R.; Borrill, J.; Bouchet, F. R.; Boulanger, F.; Bowyer, J. W.; Bridges, M.; Bucher, M.; Burigana, C.; Cardoso, J.-F.; Catalano, A.; Chamballu, A.; Chary, R.-R.; Chen, X.; Chiang, H. C.; Chiang, L.-Y.; Christensen, P. R.; Church, S.; Clements, D. L.; Colombi, S.; Colombo, L. P. L.; Combet, C.; Couchot, F.; Coulais, A.; Crill, B. P.; Curto, A.; Cuttaia, F.; Danese, L.; Davies, R. D.; Davis, R. J.; de Bernardis, P.; de Rosa, A.; de Zotti, G.; Delabrouille, J.; Delouis, J.-M.; Désert, F.-X.; Dickinson, C.; Diego, J. M.; Dole, H.; Donzelli, S.; Doré, O.; Douspis, M.; Dunkley, J.; Dupac, X.; Efstathiou, G.; Enßlin, T. A.; Eriksen, H. K.; Finelli, F.; Forni, O.; Frailis, M.; Fraisse, A. A.; Franceschi, E.; Galeotta, S.; Ganga, K.; Giard, M.; Giardino, G.; Girard, D.; Giraud-Héraud, Y.; González-Nuevo, J.; Górski, K. M.; Gratton, S.; Gregorio, A.; Gruppuso, A.; Gudmundsson, J. E.; Hansen, F. K.; Hanson, D.; Harrison, D.; Helou, G.; Henrot-Versillé, S.; Herent, O.; Hernández-Monteagudo, C.; Herranz, D.; Hildebrandt, S. R.; Hivon, E.; Hobson, M.; Holmes, W. A.; Hornstrup, A.; Hou, Z.; Hovest, W.; Huffenberger, K. M.; Hurier, G.; Jaffe, A. H.; Jaffe, T. R.; Jones, W. C.; Juvela, M.; Keihänen, E.; Keskitalo, R.; Kisner, T. S.; Kneissl, R.; Knoche, J.; Knox, L.; Kunz, M.; Kurki-Suonio, H.; Lagache, G.; Lamarre, J.-M.; Lasenby, A.; Laureijs, R. J.; Lawrence, C. R.; Le Jeune, M.; Leonardi, R.; Leroy, C.; Lesgourgues, J.; Liguori, M.; Lilje, P. B.; Linden-Vørnle, M.; López-Caniego, M.; Lubin, P. M.; Macías-Pérez, J. F.; MacTavish, C. J.; Maffei, B.; Mandolesi, N.; Maris, M.; Marleau, F.; Marshall, D. J.; Martin, P. G.; Martínez-González, E.; Masi, S.; Massardi, M.; Matarrese, S.; Matthai, F.; Mazzotta, P.; McGehee, P.; Meinhold, P. R.; Melchiorri, A.; Melot, F.; Mendes, L.; Mennella, A.; Migliaccio, M.; Mitra, S.; Miville-Deschênes, M.-A.; Moneti, A.; Montier, L.; Morgante, G.; Mortlock, D.; Mottet, S.; Munshi, D.; Murphy, J. A.; Naselsky, P.; Nati, F.; Natoli, P.; Netterfield, C. B.; Nørgaard-Nielsen, H. U.; North, C.; Noviello, F.; Novikov, D.; Novikov, I.; Orieux, F.; Osborne, S.; Oxborrow, C. A.; Paci, F.; Pagano, L.; Pajot, F.; Paladini, R.; Paoletti, D.; Pasian, F.; Patanchon, G.; Perdereau, O.; Perotto, L.; Perrotta, F.; Piacentini, F.; Piat, M.; Pierpaoli, E.; Pietrobon, D.; Plaszczynski, S.; Pointecouteau, E.; Polenta, G.; Ponthieu, N.; Popa, L.; Poutanen, T.; Pratt, G. W.; Prézeau, G.; Prunet, S.; Puget, J.-L.; Rachen, J. P.; Racine, B.; Reach, W. T.; Rebolo, R.; Reinecke, M.; Remazeilles, M.; Renault, C.; Ricciardi, S.; Riller, T.; Ristorcelli, I.; Rocha, G.; Rosset, C.; Roudier, G.; Rowan-Robinson, M.; Rusholme, B.; Sanselme, L.; Santos, D.; Sauvé, A.; Savini, G.; Scott, D.; Shellard, E. P. S.; Spencer, L. D.; Starck, J.-L.; Stolyarov, V.; Stompor, R.; Sudiwala, R.; Sureau, F.; Sutton, D.; Suur-Uski, A.-S.; Sygnet, J.-F.; Tauber, J. A.; Tavagnacco, D.; Techene, S.; Terenzi, L.; Tomasi, M.; Tristram, M.; Tucci, M.; Umana, G.; Valenziano, L.; Valiviita, J.; Van Tent, B.; Vibert, L.; Vielva, P.; Villa, F.; Vittorio, N.; Wade, L. A.; Wandelt, B. D.; White, S. D. M.; Yvon, D.; Zacchei, A.; Zonca, A.

    2014-11-01

    Wedescribe the processing of the 531 billion raw data samples from the High Frequency Instrument (HFI), which we performed to produce six temperature maps from the first 473 days of Planck-HFI survey data. These maps provide an accurate rendition of the sky emission at 100, 143, 217, 353, 545, and 857GHz with an angular resolution ranging from 9.´7 to 4.´6. The detector noise per (effective) beam solid angle is respectively, 10, 6 , 12, and 39 μK in the four lowest HFI frequency channels (100-353GHz) and 13 and 14 kJy sr-1 in the 545 and 857 GHz channels. Relative to the 143 GHz channel, these two high frequency channels are calibrated to within 5% and the 353 GHz channel to the percent level. The 100 and 217 GHz channels, which together with the 143 GHz channel determine the high-multipole part of the CMB power spectrum (50 <ℓ < 2500), are calibrated relative to 143 GHz to better than 0.2%.

  1. Patient and surgeon radiation exposure during spinal instrumentation using intraoperative computed tomography-based navigation.

    PubMed

    Mendelsohn, Daniel; Strelzow, Jason; Dea, Nicolas; Ford, Nancy L; Batke, Juliet; Pennington, Andrew; Yang, Kaiyun; Ailon, Tamir; Boyd, Michael; Dvorak, Marcel; Kwon, Brian; Paquette, Scott; Fisher, Charles; Street, John

    2016-03-01

    Imaging modalities used to visualize spinal anatomy intraoperatively include X-ray studies, fluoroscopy, and computed tomography (CT). All of these emit ionizing radiation. Radiation emitted to the patient and the surgical team when performing surgeries using intraoperative CT-based spine navigation was compared. This is a retrospective cohort case-control study. Seventy-three patients underwent CT-navigated spinal instrumentation and 73 matched controls underwent spinal instrumentation with conventional fluoroscopy. Effective doses of radiation to the patient when the surgical team was inside and outside of the room were analyzed. The number of postoperative imaging investigations between navigated and non-navigated cases was compared. Intraoperative X-ray imaging, fluoroscopy, and CT dosages were recorded and standardized to effective doses. The number of postoperative imaging investigations was compared with the matched cohort of surgical cases. A literature review identified historical radiation exposure values for fluoroscopic-guided spinal instrumentation. The 73 navigated operations involved an average of 5.44 levels of instrumentation. Thoracic and lumbar instrumentations had higher radiation emission from all modalities (CT, X-ray imaging, and fluoroscopy) compared with cervical cases (6.93 millisievert [mSv] vs. 2.34 mSv). Major deformity and degenerative cases involved more radiation emission than trauma or oncology cases (7.05 mSv vs. 4.20 mSv). On average, the total radiation dose to the patient was 8.7 times more than the radiation emitted when the surgical team was inside the operating room. Total radiation exposure to the patient was 2.77 times the values reported in the literature for thoracolumbar instrumentations performed without navigation. In comparison, the radiation emitted to the patient when the surgical team was inside the operating room was 2.50 lower than non-navigated thoracolumbar instrumentations. The average total radiation

  2. Trigonal Cu2-II-Sn-VI4 (II = Ba, Sr and VI = S, Se) quaternary compounds for earth-abundant photovoltaics.

    PubMed

    Hong, Feng; Lin, Wenjun; Meng, Weiwei; Yan, Yanfa

    2016-02-14

    We propose trigonal Cu2-II-Sn-VI4 (II = Ba, Sr and VI = S, Se) quaternary compounds for earth-abundant solar cell applications. Through density functional theory calculations, we show that these compounds exhibit similar electronic and optical properties to kesterite Cu2ZnSnS4 (CZTS): high optical absorption with band gaps suitable for efficient single-junction solar cell applications. However, the trigonal Cu2-II-Sn-VI4 compounds exhibit defect properties more suitable for photovoltaic applications than those of CZTS. In CZTS, the dominant defects are the deep acceptors, Cu substitutions on Zn sites, which cause non-radiative recombination and limit the open-circuit voltages of CZTS solar cells. On the contrary, the dominant defects in trigonal Cu2-II-Sn-VI4 are the shallow acceptors, Cu vacancies, similar to those in CuInSe2. Our results suggest that the trigonal Cu2-II-Sn-VI4 quaternary compounds could be promising candidates for efficient earth-abundant thin-film solar cell and photoeletrochemical water-splitting applications.

  3. New generation ion-imprinted nanocarrier for removal of Cr(VI) from wastewater

    NASA Astrophysics Data System (ADS)

    Uygun, Murat; Feyzioğlu, Esra; Özçalışkan, Emir; Caka, Müşerref; Ergen, Aygen; Akgöl, Sinan; Denizli, Adil

    2013-08-01

    The purpose of this study was to prepare a novel ion-imprinted nanoparticle to remove Cr(VI) ions from waste water. For this, Cr(VI) ions were complexed with 2-methacryloylamido histidine (MAH) and then Cr(VI)-imprinted poly(HEMAH) nanoparticles were synthesized by surfactant-free emulsion polymerization technique. The templates, Cr(VI) ions, were removed from the nanoparticles using 0.1 M of HNO3 solution. The specific surface area of the Cr(VI)-imprinted poly(HEMAH) nanoparticles was found to be 1,397.85 m2/g, and the particle size was calculated as 155.3 nm. These Cr(VI)-imprinted nanoparticles were used for the adsorption/desorption of Cr(VI) ions from its aqueous solutions. The effects of initial Cr(VI) concentration and medium pH on the Cr(VI) adsorption capacity were also studied. The maximum adsorbed amount of Cr(VI) on the imprinted nanoparticles was found to be 3,830.58 mg/g nanoparticle in pH 4.0. In order to investigate the selectivity of the imprinted nanoparticle, adsorption studies were repeated using Cr(III) ions. The selectivity results demonstrated that Cr(VI)-imprinted poly(HEMAH) nanoparticles showed high affinity for the Cr(VI) ions than Cr(III). The Cr(VI)-imprinted nanoparticles were used several times without decreasing their Cr(VI) adsorption capacities.

  4. Rheology of water ices V and VI

    USGS Publications Warehouse

    Durham, W.B.; Stern, L.A.; Kirby, S.H.

    1996-01-01

    We have measured the mechanical strength (??) of pure water ices V and VI under steady state deformation conditions. Constant displacement rate compressional tests were conducted in a gas apparatus at confining pressures from 400 250 K. Ices V and VI are thus Theologically distinct but by coincidence have approximately the same strength under the conditions chosen for these experiments. To avoid misidentification, these tests are therefore accompanied by careful observations of the occurrences and characteristics of phase changes. One sample each of ice V and VI was quenched at pressure to metastably retain the high-pressure phase and the acquired deformation microstructures; X ray diffraction analysis of these samples confirmed the phase identification. Surface replicas of the deformed and quenched samples suggest that ice V probably deforms largely by dislocation creep, while ice VI deforms by a more complicated process involving substantial grain size reduction through recrystallization.

  5. Compact instrument for fluorescence image-guided surgery

    NASA Astrophysics Data System (ADS)

    Wang, Xinghua; Bhaumik, Srabani; Li, Qing; Staudinger, V. Paul; Yazdanfar, Siavash

    2010-03-01

    Fluorescence image-guided surgery (FIGS) is an emerging technique in oncology, neurology, and cardiology. To adapt intraoperative imaging for various surgical applications, increasingly flexible and compact FIGS instruments are necessary. We present a compact, portable FIGS system and demonstrate its use in cardiovascular mapping in a preclinical model of myocardial ischemia. Our system uses fiber optic delivery of laser diode excitation, custom optics with high collection efficiency, and compact consumer-grade cameras as a low-cost and compact alternative to open surgical FIGS systems. Dramatic size and weight reduction increases flexibility and access, and allows for handheld use or unobtrusive positioning over the surgical field.

  6. Hydrocarbon oxidation by beta-halogenated dioxoruthenium(VI) porphyrin complexes: effect of reduction potential (RuVI/V) and C-H bond-dissociation energy on rate constants.

    PubMed

    Che, Chi-Ming; Zhang, Jun-Long; Zhang, Rui; Huang, Jie-Sheng; Lai, Tat-Shing; Tsui, Wai-Man; Zhou, Xiang-Ge; Zhou, Zhong-Yuan; Zhu, Nianyong; Chang, Chi Kwong

    2005-11-18

    beta-Halogenated dioxoruthenium(VI) porphyrin complexes [Ru(VI)(F(28)-tpp)O(2)] [F(28)-tpp=2,3,7,8,12,13, 17,18-octafluoro-5,10,15,20-tetrakis(pentafluorophenyl)porphyrinato(2-)] and [Ru(VI)(beta-Br(8)-tmp)O(2)] [beta-Br(8)-tmp=2,3,7,8,12,13,17,18-octabromo-5,10,15,20- tetrakis(2,4,6-trimethylphenyl)porphyrinato(2-)] were prepared from reactions of [Ru(II)(por)(CO)] [por=porphyrinato(2-)] with m-chloroperoxybenzoic acid in CH(2)Cl(2). Reactions of [Ru(VI)(por)O(2)] with excess PPh(3) in CH(2)Cl(2) gave [Ru(II)(F(20)-tpp)(PPh(3))(2)] [F(20)-tpp=5,10,15,20-tetrakis(pentafluorophenyl)porphyrinato(2-)] and [Ru(II)(F(28)-tpp)(PPh(3))(2)]. The structures of [Ru(II)(por)(CO)(H(2)O)] and [Ru(II)(por)(PPh(3))(2)] (por=F(20)-tpp, F(28)-tpp) were determined by X-ray crystallography, revealing the effect of beta-fluorination of the porphyrin ligand on the coordination of axial ligands to ruthenium atom. The X-ray crystal structure of [Ru(VI)(F(20)-tpp)O(2)] shows a Ru=O bond length of 1.718(3) A. Electrochemical reduction of [Ru(VI)(por)O(2)] (Ru(VI) to Ru(V)) is irreversible or quasi-reversible, with the E(p,c)(Ru(VI/V)) spanning -0.31 to -1.15 V versus Cp(2)Fe(+/0). Kinetic studies were performed for the reactions of various [Ru(VI)(por)O(2)], including [Ru(VI)(F(28)-tpp)O(2)] and [Ru(VI)(beta-Br(8)-tmp)O(2)], with para-substituted styrenes p-X-C(6)H(4)CH=CH(2) (X=H, F, Cl, Me, MeO), cis- and trans-beta-methylstyrene, cyclohexene, norbornene, ethylbenzene, cumene, 9,10-dihydroanthracene, xanthene, and fluorene. The second-order rate constants (k(2)) obtained for the hydrocarbon oxidations by [Ru(VI)(F(28)-tpp)O(2)] are up to 28-fold larger than by [Ru(VI)(F(20)-tpp)O(2)]. Dual-parameter Hammett correlation implies that the styrene oxidation by [Ru(VI)(F(28)-tpp)O(2)] should involve rate-limiting generation of a benzylic radical intermediate, and the spin delocalization effect is more important than the polar effect. The k(2) values for the oxidation of styrene and

  7. Oxidation of trimethoprim by ferrate(VI): kinetics, products, and antibacterial activity.

    PubMed

    Anquandah, George A K; Sharma, Virender K; Knight, D Andrew; Batchu, Sudha Rani; Gardinali, Piero R

    2011-12-15

    Kinetics, stoichiometry, and products of the oxidation of trimethoprim (TMP), one of the most commonly detected antibacterial agents in surface waters and municipal wastewaters, by ferrate(VI) (Fe(VI)) were determined. The pH dependent second-order rate constants of the reactions of Fe(VI) with TMP were examined using acid-base properties of Fe(VI) and TMP. The kinetics of reactions of diaminopyrimidine (DAP) and trimethoxytoluene (TMT) with Fe(VI) were also determined to understand the reactivity of Fe(VI) with TMP. Oxidation products of the reactions of Fe(VI) with TMP and DAP were identified by liquid chromatography-tandem mass spectrometry (LC-MS/MS). Reaction pathways of oxidation of TMP by Fe(VI) are proposed to demonstrate the cleavage of the TMP molecule to ultimately result in 3,4,5,-trimethoxybenzaldehyde and 2,4-dinitropyrimidine as among the final identified products. The oxidized products mixture exhibited no antibacterial activity against E. coli after complete consumption of TMP. Removal of TMP in the secondary effluent by Fe(VI) was achieved.

  8. [Zwipp Percutaneous Suture of the Achilles Tendon with the Dresden Instruments].

    PubMed

    Chmielnicki, M; Prokop, A

    2016-06-01

    Rupture of the Achilles tendon is the most common rupture of a tendon in man. Acute rupture of the Achilles tendon may be treated in a variety of manners, including conservative treatment, open suture and percutaneous suture. Surgical treatment of active patients is recommended, as the risk of re-rupture is greater after non-surgical treatment. The aim of surgery is adequate treatment of Achilles tendon rupture with a low rate of complications, high comfort for patients and fast social and occupational rehabilitation. The indication for surgical treatment of Achilles tendon rupture predominantly includes ruptures in active patients, with the goal of optimal functional rehabilitation. Furthermore, the percutaneous technique protects soft tissue, with a lower rate of wound healing disorders and infection than with open surgical treatment. In our clinic we perform the percutaneous suturing technique with the Dresden instruments. The surgical technique and functional aftercare are shown in a video clip. Between 2007 and 2013, we treated 212 patients with acute Achilles tendon rupture by surgery with the Dresden instruments. There were 7 re-ruptures (3.3 %) and one case of infection within one year of surgery. Percutaneous Achilles tendon suture technique with the Dresden instruments is a safe operation that protects soft tissue. Patient satisfaction is high and the rate of complications is low. This allows rapid social and occupational rehabilitation. Georg Thieme Verlag KG Stuttgart · New York.

  9. Surgical implantation of transmitters into fish

    USGS Publications Warehouse

    Mulcahy, Daniel M.

    2003-01-01

    Although the Animal Welfare Act does not cover poikilotherms, individual institutions and policies and legal requirements other than the Animal Welfare Act (e.g., the US Public Health Service and the Interagency Research Animal Committee's Principles for the Utilization and Care of Vertebrate Animals Used in Testing, Research, and Training) require the review of projects involving fish by institutional animal care and use committees (IACUCs). IACUCs may, however, lack the knowledge and experience to evaluate fish projects judiciously, especially when the projects are in field settings. Surgeries involving implantation of transmitters and other instruments into the coelom, which now comprise a very common research tool in the study of free-ranging fishes, are examples of surgeries that use a broad spectrum of surgical and anesthetic techniques, some of which would not be considered acceptable for similar work on mammals. IACUCs should apply the standards they would expect to be used for surgeries on homeotherms to surgeries on fish. Surgeons should be carefully trained and experienced. Surgical instruments and transmitters should be sterile. Regulations and laws on the use of drugs in animals should be followed, particularly those concerned with anesthetics and antibiotics used on free-ranging fish. Exceptions to surgical procedures should be made only when circumstances are extreme enough to warrant the use of less than optimal procedures.

  10. Kinetics of Microbial Reduction of Solid Phase U(VI)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, Chongxuan; Jeon, Byong Hun; Zachara, John M.

    2006-10-01

    Sodium boltwoodite (NaUO2SiO3OH ?1.5H2O) was used to assess the kinetics of microbial reduction of solid phase U(VI) by a dissimilatory metal-reducing bacterium (DMRB), Shewanella oneidensis strain MR-1. The bioreduction kinetics was studied with Na-boltwoodite in suspension or within alginate beads. Concentrations of U(VI)tot and cell number were varied to evaluate the coupling of U(VI) dissolution, diffusion, and microbial activity. Batch experiments were performed in a non-growth medium with lactate as electron donor at pH 6.8 buffered with PIPES. Microscopic and spectroscopic analyses with transmission electron microscopy (TEM), energy dispersive spectroscopy (EDS), and laser-induced fluorescence spectroscopy (LIFS) collectively indicated that solidmore » phase U(VI) was first dissolved and diffused out of grain interiors before it was reduced on bacterial surfaces and/or within the periplasm. The kinetics of solid phase U(VI) bioreduction was well described by a coupled model of bicarbonate-promoted dissolution of Na-boltwoodite, intraparticle uranyl diffusion, and Monod type bioreduction kinetics with respect to dissolved U(VI) concentration. The results demonstrated the intimate coupling of biological, chemical, and physical processes in microbial reduction of solid phase U(VI).« less

  11. The FUSE Survey of 0 VI in the Galactic Halo

    NASA Technical Reports Server (NTRS)

    Sonneborn, George; Savage, B. D.; Wakker, B. P.; Sembach, K. R.; Jenkins, E. B.; Moos, H. W.; Shull, J. M.

    2003-01-01

    This paper summarizes the results of the Far-Ultraviolet Spectroscopic Explorer (FUSE) program to study 0 VI in the Milky Way halo. Spectra of 100 extragalactic objects and two distant halo stars are analyzed to obtain measures of O VI absorption along paths through the Milky Way thick disk/halo. Strong O VI absorption over the velocity range from -100 to 100 km/s reveals a widespread but highly irregular distribution of O VI, implying the existence of substantial amounts of hot gas with T approx. 3 x 10(exp 5) K in the Milky Way thick disk/halo. The overall distribution of O VI is not well described by a symmetrical plane-parallel layer of patchy O VI absorption. The simplest departure from such a model that provides a reasonable fit to the observations is a plane-parallel patchy absorbing layer with an average O VI mid-plane density of n(sub 0)(O VI) = 1.7 x 10(exp -2)/cu cm, a scale height of approx. 2.3 kpc, and a approx. 0.25 dex excess of O VI in the northern Galactic polar region. The distribution of O VI over the sky is poorly correlated with other tracers of gas in the halo, including low and intermediate velocity H I, Ha emission from the warm ionized gas at approx. l0(exp 4) K, and hot X-ray emitting gas at approx. l0(exp 6) K . The O VI has an average velocity dispersion, b approx. 60 km/s and standard deviation of 15 km/s. Thermal broadening alone cannot explain the large observed profile widths. A combination of models involving the radiative cooling of hot fountain gas, the cooling of supernova bubbles in the halo, and the turbulent mixing of warm and hot halo gases is required to explain the presence of O VI and other highly ionized atoms found in the halo. The preferential venting of hot gas from local bubbles and superbubbles into the northern Galactic polar region may explain the enhancement of O VI in the North.

  12. Design, baseline characteristics, and early findings of the MPS VI (mucopolysaccharidosis VI) Clinical Surveillance Program (CSP).

    PubMed

    Hendriksz, Christian J; Giugliani, Roberto; Harmatz, Paul; Lampe, Christina; Martins, Ana Maria; Pastores, Gregory M; Steiner, Robert D; Leão Teles, Elisa; Valayannopoulos, Vassili

    2013-03-01

    To outline the design, baseline data, and 5-year follow-up data of patients with mucopolysaccharidosis (MPS) VI enrolled in the Clinical Surveillance Program (CSP), a voluntary, multinational, observational program. The MPS VI CSP was opened in 2005 to collect, for at least 15 years, observational data from standard clinical and laboratory assessments of patients with MPS VI. Baseline and follow-up data are documented by participating physicians in electronic case report forms. Between September 2005 and March 2010 the CSP enrolled 132 patients, including 123 who received enzyme replacement therapy (ERT) with galsulfase. Median age at enrolment was 13 years (range 1-59). Mean baseline data showed impaired growth, hepatosplenomegaly, and reduced endurance and pulmonary function. The most common findings were heart valve disease (90%), reduced visual acuity (79%), impaired hearing (59%), and hepatosplenomegaly (54%). Follow-up data up to 5 years in patients with pre- and post-ERT measurements showed a decrease in urinary glycosaminoglycans and increases in height and weight in patients <16 years and suggested reductions in liver and spleen size and improvements in endurance and pulmonary function after ERT was started. Vision, hearing, and cardiac function were unchanged. Safety data were in line with previous reports. The CSP represents the largest cross-sectional study of MPS VI to date. This first report provides information on the design and implementation of the program and population statistics for several clinical variables in patients with MPS VI. Data collected over 5 years suggest that ERT provides clinical benefit and is well-tolerated with no new safety concerns.

  13. Adjacent segment infection after surgical treatment of spondylodiscitis.

    PubMed

    Siam, Ahmed Ezzat; El Saghir, Hesham; Boehm, Heinrich

    2016-03-01

    This is the first case series to describe adjacent segment infection (ASI) after surgical treatment of spondylodiscitis (SD). Patients with SD, spondylitis who were surgically treated between 1994 and 2012 were included. Out of 1187 cases, 23 (1.94 %) returned to our institution (Zentralklinik Bad Berka) with ASI: 10 males, 13 females, with a mean age of 65.1 years and a mean follow-up of 69 months. ASI most commonly involved L3-4 (seven patients), T12-L1 (five) and L2-3 (four). The mean interval between operations of primary infection and ASI was 36.9 months. All cases needed surgical intervention, debridement, reconstruction and fusion with longer instrumentation, with culture and sensitivity-based postoperative antimicrobial therapy. At last follow-up, six patients (26.1 %) were mobilized in a wheelchair with a varying degree of paraplegia (three had pre-existing paralysis). Three patients died within 2 months after the ASI operation (13 %). Excellent outcomes were achieved in five patients, and good in eight. Adjacent segment infection after surgical treatment of spondylodiscitis is a rare complication (1.94 %). It is associated with multimorbidity and shows a high mortality rate and a high neurological affection rate. Possible explanations are: haematomas of repeated micro-fractures around screw loosening, haematogenous spread, direct inoculation or a combination of these factors. ASI may also lead to proximal junctional kyphosis, as found in this series. We suggest early surgical intervention with anterior debridement, reconstruction and fusion with posterior instrumentation, followed by antimicrobial therapy for 12 weeks. Level IV retrospective uncontrolled case series.

  14. Acute Perioperative Comparison of Patient-Specific Instrumentation versus Conventional Instrumentation Utilization during Bilateral Total Knee Arthroplasty.

    PubMed

    Steimle, Jerrod A; Groover, Michael T; Webb, Brad A; Ceccarelli, Brian J

    2018-01-01

    Utilizing patient-specific instrumentation during total knee arthroplasty has gained popularity in recent years with theoretical advantages in blood loss, intraoperative time, length of stay, postoperative alignment, and functional outcome, amongst others. No study has compared acute perioperative measures between patient-specific instrumentation and conventional instrumentation in the bilateral total knee arthroplasty setting. We compared patient-specific instrumentation versus conventional instrumentation in the setting of bilateral total knee arthroplasty to determine any benefits in the immediate perioperative period including surgical time, blood loss, pain medication use, length of stay, and discharge disposition. A total of 49 patients with standard instrumentation and 31 patients with patient-specific instrumentation were retrospectively reviewed in a two-year period at one facility. At baseline, the groups were comparable with respect to age, ASA, BMI, and comorbid conditions. We analyzed data on operative time, blood loss, hemoglobin change, need for transfusion, pain medication use, length of stay, and discharge disposition. There was no statistically significant difference between groups in regards to these parameters. Patient-specific instrumentation in the setting of bilateral total knee arthroplasty did not provide any immediate perioperative benefit compared to conventional instrumentation.

  15. Surgical speech disorders.

    PubMed

    Shen, Tianjie; Sie, Kathleen C Y

    2014-11-01

    Most speech disorders of childhood are treated with speech therapy. However, two conditions, ankyloglossia and velopharyngeal dysfunction, may be amenable to surgical intervention. It is important for surgeons to work with experienced speech language pathologists to diagnose the speech disorder. Children with articulation disorders related to ankyloglossia may benefit from frenuloplasty. Children with velopharyngeal dysfunction should have standardized clinical evaluation and instrumental asseessment of velopharyngeal function. Surgeons should develop a treatment protocol to optimize speech outcomes while minimizing morbidity. Copyright © 2014 Elsevier Inc. All rights reserved.

  16. Comparative healing of rat fascia following incision with three surgical instruments.

    PubMed

    Chang, Edward I; Carlson, Grace A; Vose, Joshua G; Huang, Eric J; Yang, George P

    2011-05-01

    Incisional hernia and fascial dehiscence are associated with significant postoperative morbidity. Electrosurgical devices using pulsed radiofrequency energy and a novel electrode design markedly reduce thermal injury during cutting and coagulation while maintaining equal surgical performance. In this study, we examine fascial healing dynamics in a rat model following incision with a pulsed radiofrequency energy device (PRE), a conventional electrosurgical device, and a standard "cold" scalpel. We hypothesize that incisions made with the pulsed radiofrequency energy device will result in a superior fascial healing profile compared with conventional electrosurgery. Full thickness surgical incisions were created in rat fascia using a commercially available PRE device, conventional electrosurgery, and a scalpel. Harvested fascial specimens were analyzed for burst strength testing and healing-associated histologic characteristics at d 7, 14, 21, and 42. PRE incisions were fully healed by 6 wk with normal tissue architecture. By all measures, wounds created by the PRE device were comparable to those made with the standard scalpel. Compared with PRE, conventional electrosurgery incisions exhibited a larger zone of tissue injury (68% greater in Coag mode, P < 0.0001; 46% greater in Cut mode, P < 0.001), an increased inflammatory response and a less favorable wound architecture. In the immediate postoperative period (1 wk), burst strength testing demonstrated that PRE fascial wounds were significantly stronger than those made by electrosurgery in Coag mode (318%, P = 0.001). The favorable fascial healing profile of the PRE device suggests that it is a promising new surgical technology. The early improved strength of wounds made with this device is of particular interest, as wound dehiscence is of greatest concern early in the healing process. Published by Elsevier Inc.

  17. Postoperative urinary tract infection and surgical site infection in instrumented spinal surgery: is there a link?

    PubMed

    Núñez-Pereira, S; Rodríguez-Pardo, D; Pellisé, F; Pigrau, C; Bagó, J; Villanueva, C; Cáceres, E

    2014-08-01

    A potential relationship between postoperative urinary tract infection (UTI) and surgical site infection (SSI) following posterior spinal fusion and instrumentation (PSFI) was investigated. A retrospective review was performed of prospectively collected demographic, clinical and microbiological data of 466 consecutive patients (median age, 53.7 years (interquartile range (IQR) 33.8-65.6); 58.6% women) undergoing PSFI to identify those with UTI in the first 4 weeks and SSI in the first 12 weeks after PSFI. Overall, 40.8% had an American Society of Anesthesiologists score of >2, and 49.8% had undergone fusion of more than three segments. Eighty-nine patients had UTI, 54 had SSI, and 22 had both conditions. In nine of the 22 (38%) cases, the two infections were caused by the same microorganism. The urinary tract was the probable source of SSI by Gram-negative bacteria in 38% (8/21) of cases. On multivariate analysis, UTI (OR 3.1, 95% CI 1.6-6.1; P 0.001) and instrumentation of more than three segments (OR 2.7, 95% CI 1.1-6.3; P 0.024) were statistically associated with SSI. Patients receiving ciprofloxacin for UTI had higher microbial resistance rates to fluoroquinolones at SSIs (46.13%) than those without ciprofloxacin (21.9%), although the difference did not reach statistical significance (p 0.1). In our series, UTI was significantly associated with SSI after PSFI. On the basis of our results, we conclude that further efforts to reduce the incidence of postoperative UTI and provide adequate empirical antibiotic therapy that avoids quinolones whenever possible may help to reduce SSI rates and potential microbial resistance. © 2014 The Authors Clinical Microbiology and Infection © 2014 European Society of Clinical Microbiology and Infectious Diseases.

  18. Modelling biological Cr(VI) reduction in aquifer microcosm column systems.

    PubMed

    Molokwane, Pulane E; Chirwa, Evans M N

    2013-01-01

    Several chrome processing facilities in South Africa release hexavalent chromium (Cr(VI)) into groundwater resources. Pump-and-treat remediation processes have been implemented at some of the sites but have not been successful in reducing contamination levels. The current study is aimed at developing an environmentally friendly, cost-effective and self-sustained biological method to curb the spread of chromium at the contaminated sites. An indigenous Cr(VI)-reducing mixed culture of bacteria was demonstrated to reduce high levels of Cr(VI) in laboratory samples. The effect of Cr(VI) on the removal rate was evaluated at concentrations up to 400 mg/L. Following the detailed evaluation of fundamental processes for biological Cr(VI) reduction, a predictive model for Cr(VI) breakthrough through aquifer microcosm reactors was developed. The reaction rate in batch followed non-competitive rate kinetics with a Cr(VI) inhibition threshold concentration of approximately 99 mg/L. This study evaluates the application of the kinetic parameters determined in the batch reactors to the continuous flow process. The model developed from advection-reaction rate kinetics in a porous media fitted best the effluent Cr(VI) concentration. The model was also used to elucidate the logistic nature of biomass growth in the reactor systems.

  19. Problems of Determining the Content of Cr(VI) in Raw Materials and Materials Containing Chromite Ore.

    PubMed

    Stec, Katarzyna

    2017-11-02

    Materials made with chromite ore are widely applied in the industry metallurgy as well as in the foundry industry. The oxidation number of chromium in these materials is both (III) and (VI). Currently there are no procedures allowing proper determination of chrome in chromite ores and ore-containing materials. The analytical methods applied, which are dedicated to a very narrow range of materials, e.g., cement, and cannot be applied in the case of materials which, apart from trace amounts of Cr(VI), contain mainly compounds of Cr(III), Fe(III) as well as trace compounds of Cu(II), Ni(II) and V(V). In the work particular attention has been paid to the preparation of test samples and creating measurement conditions in which interferences from Cr(III) and Fe(III) spectral lines could be minimized. Two separate instrumental measurement techniques have been applied: Inductively Coupled Plasma-Atomic Emission Spectrometry (ICP AES) and the spectrophotometric method using diphenylcarbazide.

  20. Diverse functions of myosin VI elucidated by an isoform-specific α-helix domain.

    PubMed

    Wollscheid, Hans-Peter; Biancospino, Matteo; He, Fahu; Magistrati, Elisa; Molteni, Erika; Lupia, Michela; Soffientini, Paolo; Rottner, Klemens; Cavallaro, Ugo; Pozzoli, Uberto; Mapelli, Marina; Walters, Kylie J; Polo, Simona

    2016-04-01

    Myosin VI functions in endocytosis and cell motility. Alternative splicing of myosin VI mRNA generates two distinct isoform types, myosin VI(short) and myosin VI(long), which differ in the C-terminal region. Their physiological and pathological roles remain unknown. Here we identified an isoform-specific regulatory helix, named the α2-linker, that defines specific conformations and hence determines the target selectivity of human myosin VI. The presence of the α2-linker structurally defines a new clathrin-binding domain that is unique to myosin VI(long) and masks the known RRL interaction motif. This finding is relevant to ovarian cancer, in which alternative myosin VI splicing is aberrantly regulated, and exon skipping dictates cell addiction to myosin VI(short) in tumor-cell migration. The RRL interactor optineurin contributes to this process by selectively binding myosin VI(short). Thus, the α2-linker acts like a molecular switch that assigns myosin VI to distinct endocytic (myosin VI(long)) or migratory (myosin VI(short)) functional roles.

  1. 32 CFR 2003.6 - Voting (Article VI).

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 32 National Defense 6 2014-07-01 2014-07-01 false Voting (Article VI). 2003.6 Section 2003.6 National Defense Other Regulations Relating to National Defense INFORMATION SECURITY OVERSIGHT OFFICE...) BYLAWS, RULES, AND APPEAL PROCEDURES Bylaws § 2003.6 Voting (Article VI). (a) Motions. When the Panel is...

  2. 32 CFR 2003.6 - Voting (Article VI).

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 32 National Defense 6 2013-07-01 2013-07-01 false Voting (Article VI). 2003.6 Section 2003.6 National Defense Other Regulations Relating to National Defense INFORMATION SECURITY OVERSIGHT OFFICE...) BYLAWS, RULES, AND APPEAL PROCEDURES Bylaws § 2003.6 Voting (Article VI). (a) Motions. When the Panel is...

  3. A diagnostic evolution: surgical experience with popliteal artery entrapment syndrome at a military tertiary referral center.

    PubMed

    Clemens, Michael S; Scott, Daniel J; Watson, John Devin B; Wang, Lin C; Hislop, Sean J; Arthurs, Zachary M

    2015-08-01

    Popliteal artery entrapment syndrome (PAES) is an increasingly encountered disorder that typically presents as claudication in young and active individuals. However, despite the increased recognition, accurate preoperative diagnosis can be difficult. The objective of this study was to describe the surgical assessment and outcomes of patients treated for PAES. Retrospective case series of all patients managed surgically for a diagnosis of PAES at the San Antonio Military Medical Center from 2005 to 2013. Over 8 years, PAES was surgically treated in 25 consecutive limbs of 15 patients (mean age, 35; range, 21-49) in a military tertiary medical center. Type III was the most common variant (n = 13, 52%), followed by type VI (n = 7, 28%). Most patients presented with class I or II ischemia (88%), with anterolateral symptoms (56%), and were referred by orthopedics (66%). Diagnostic work-up included stress ankle-brachial indices, magnetic resonance imaging (MRI) and provocative angiography. Sixty-three percent of limbs with negative MRI demonstrated findings consistent with either type III or V PAES. Tendon release was used in those with types III and V, whereas liberal myectomy was used in those with types I, II, or VI. Two patients required revascularization. At a median follow-up of 126 days (range, 25 days-7 years), 83% of patients with type III demonstrated partial resolution of symptoms. Only 27% of patients without an identifiable muscle slip had clinical improvement. Despite modern imaging, open surgical exploration remains the definitive diagnostic modality for PAES. Patients with a muscular or tendinous slip identified intraoperatively have the best clinical outcomes. Those with no identifiable muscle slip (functional entrapment) are less likely to demonstrate clinical improvement. Further evaluation on outcomes in the management in PAES is warranted. Published by Elsevier Inc.

  4. Design and implementation of a PC-based image-guided surgical system.

    PubMed

    Stefansic, James D; Bass, W Andrew; Hartmann, Steven L; Beasley, Ryan A; Sinha, Tuhin K; Cash, David M; Herline, Alan J; Galloway, Robert L

    2002-11-01

    In interactive, image-guided surgery, current physical space position in the operating room is displayed on various sets of medical images used for surgical navigation. We have developed a PC-based surgical guidance system (ORION) which synchronously displays surgical position on up to four image sets and updates them in real time. There are three essential components which must be developed for this system: (1) accurately tracked instruments; (2) accurate registration techniques to map physical space to image space; and (3) methods to display and update the image sets on a computer monitor. For each of these components, we have developed a set of dynamic link libraries in MS Visual C++ 6.0 supporting various hardware tools and software techniques. Surgical instruments are tracked in physical space using an active optical tracking system. Several of the different registration algorithms were developed with a library of robust math kernel functions, and the accuracy of all registration techniques was thoroughly investigated. Our display was developed using the Win32 API for windows management and tomographic visualization, a frame grabber for live video capture, and OpenGL for visualization of surface renderings. We have begun to use this current implementation of our system for several surgical procedures, including open and minimally invasive liver surgery.

  5. Distribution and Kinematics of O VI in the Galactic Halo

    NASA Astrophysics Data System (ADS)

    Savage, B. D.; Sembach, K. R.; Wakker, B. P.; Richter, P.; Meade, M.; Jenkins, E. B.; Shull, J. M.; Moos, H. W.; Sonneborn, G.

    2003-05-01

    Far-Ultraviolet Spectroscopic Explorer (FUSE) spectra of 100 extragalactic objects and two distant halo stars are analyzed to obtain measures of O VI λλ1031.93, 1037.62 absorption along paths through the Milky Way thick disk/halo. Strong O VI absorption over the velocity range from -100 to 100 km s-1 reveals a widespread but highly irregular distribution of O VI, implying the existence of substantial amounts of hot gas with T~3×105 K in the Milky Way thick disk/halo. The integrated column density, log[N(O VI) cm-2], ranges from 13.85 to 14.78 with an average value of 14.38 and a standard deviation of 0.18. Large irregularities in the gas distribution are found to be similar over angular scales extending from <1° to 180°, implying a considerable amount of small- and large-scale structure in the absorbing gas. The overall distribution of O VI is not well described by a symmetrical plane-parallel layer of patchy O VI absorption. The simplest departure from such a model that provides a reasonable fit to the observations is a plane-parallel patchy absorbing layer with an average O VI midplane density of n0(O VI)=1.7×10-8 cm-3, a scale height of ~2.3 kpc, and a ~0.25 dex excess of O VI in the northern Galactic polar region. The distribution of O VI over the sky is poorly correlated with other tracers of gas in the halo, including low- and intermediate-velocity H I, Hα emission from the warm ionized gas at ~104 K, and hot X-ray-emitting gas at ~106 K. The O VI has an average velocity dispersion, b~60 km s-1, and standard deviation of 15 km s-1. Thermal broadening alone cannot explain the large observed profile widths. The average O VI absorption velocities toward high-latitude objects (|b|>45deg) range from -46 to 82 km s-1, with a high-latitude sample average of 0 km s-1 and a standard deviation of 21 km s-1. High positive velocity O VI absorbing wings extending from ~100 to ~250 km s-1 observed along 21 lines of sight may be tracing the flow of O VI into the halo

  6. Systematic review of reusable versus disposable laparoscopic instruments: costs and safety.

    PubMed

    Siu, Joey; Hill, Andrew G; MacCormick, Andrew D

    2017-01-01

    The quality of instruments and surgical expertise in minimally invasive surgery has developed markedly in the last two decades. Attention is now being turned to ways to allow surgeons to adopt more cost-effective and environmental-friendly approaches. This review explores current evidence on the cost and environmental impact of reusable versus single-use instruments. In addition, we aim to compare their quality, functionality and associated clinical outcomes. The Medline and EMBASE databases were searched for relevant literature from January 2000 to May 2015. Subject headings were Equipment Reuse/, Disposable Equipment/, Cholecystectomy/, Laparoscopic/, Laparoscopy/, Surgical Instruments/, Medical Waste Disposal/, Waste Management/, Medical Waste/, Environmental Sustainability/ and Sterilization/. There are few objective comparative analyses between single-use versus reusable instruments. Current evidence suggests that limiting use of disposal instruments to necessity may hold both economical and environmental advantages. Theoretical advantages of single-use instruments in quality, safety, sterility, ease of use and importantly patient outcomes have rarely been examined. Cost-saving methods, environmental-friendly methods, global operative costs, hidden costs, sterilization methods and quality assurance systems vary greatly between studies making it difficult to gain an overview of the comparison between single-use and reusable instruments. Further examination of cost comparisons between disposable and reusable instruments is necessary while externalized environmental costs, instrument function and safety are also important to consider in future studies. © 2016 Royal Australasian College of Surgeons.

  7. Degradation of chloramphenicol by potassium ferrate (VI) oxidation: kinetics and products.

    PubMed

    Zhou, Jia-Heng; Chen, Kai-Bo; Hong, Qian-Kun; Zeng, Fan-Cheng; Wang, Hong-Yu

    2017-04-01

    The oxidation of chloramphenicol (CAP) by potassium ferrate (VI) in test solution was studied in this paper. A series of jar tests were performed at bench scale with pH of 5-9 and molar ratio [VI/CAP] of 16.3:1-81.6:1. Results showed that raising VI dose could improve the treatment performance and the influence of solution pH was significant. VI is more reactive in neutral conditions, presenting the highest removal efficiency of CAP. The rate law for the oxidation of CAP by VI was first order with respect to each reactant, yielding an overall second-order reaction. Furthermore, five oxidation products were observed during CAP oxidation by VI. Results revealed that VI attacked the amide group of CAP, leading to the cleavage of the group, while benzene ring remained intact.

  8. Chromium(VI) generation in vadose zone soils and alluvial sediments of the southwestern Sacramento Valley, California: a potential source of geogenic Cr(VI) to groundwater

    USGS Publications Warehouse

    Mills, Christopher T.; Morrison, Jean M.; Goldhaber, Martin B.; Ellefsen, Karl J.

    2011-01-01

    Concentrations of geogenic Cr(VI) in groundwater that exceed the World Health Organization’s maximum contaminant level for drinking water (50 μg L−1) occur in several locations globally. The major mechanism for mobilization of this Cr(VI) at these sites is the weathering of Cr(III) from ultramafic rocks and its subsequent oxidation on Mn oxides. This process may be occurring in the southern Sacramento Valley of California where Cr(VI) concentrations in groundwater can approach or exceed 50 μg L−1. To characterize Cr geochemistry in the area, samples from several soil auger cores (approximately 4 m deep) and drill cores (approximately 25 m deep) were analyzed for total concentrations of 44 major, minor and trace elements, Cr associated with labile Mn and Fe oxides, and Cr(VI). Total concentrations of Cr in these samples ranged from 140 to 2220 mg per kg soil. Between 9 and 70 mg per kg soil was released by selective extractions that target Fe oxides, but essentially no Cr was associated with the abundant reactive Mn oxides (up to ~1000 mg hydroxylamine-reducible Mn per kg soil was present). Both borehole magnetic susceptibility surveys performed at some of the drill core sites and relative differences between Cr released in a 4-acid digestion versus total Cr (lithium metaborate fusion digestion) suggest that the majority of total Cr in the samples is present in refractory chromite minerals transported from ultramafic exposures in the Coast Range Mountains. Chromium(VI) in the samples studied ranged from 0 to 42 μg kg−1, representing a minute fraction of total Cr. Chromium(VI) content was typically below detection in surface soils (top 10 cm) where soil organic matter was high, and increased with increasing depth in the soil auger cores as organic matter decreased. Maximum concentrations of Cr(VI) were up to 3 times greater in the deeper drill core samples than the shallow auger cores. Although Cr(VI) in these vadose zone soils and sediments was only a

  9. Stabilization of Cr(VI) from fine ferrochrome dust using exfoliated vermiculite.

    PubMed

    Mulange Wa Mulange, Delphin; Garbers-Craig, Andrie Mariana

    2012-07-15

    This study proved that vermiculite, a natural occurring mineral, can effectively remove and stabilize Cr(VI) from fine ferrochrome dust leachate. Batch adsorption studies were carried out to determine the effect of pH, contact time and adsorbent dose on the removal of Cr(VI). The process was found to be highly pH dependent. The optimum conditions for the Cr(VI) removal are at a pH of 1.5, contact time of 2h and adsorbent dose of 10gL(-1). The stability of the Cr(VI)-loaded vermiculite remained unchanged after 12 months, when the vermiculite was evaluated with the ASTM and TCLP Cr(VI) leach methods. However, Cr(VI) desorption did take place when the Acid Rain Test was used. The adsorption kinetic data fits the pseudo-second order model, while the equilibrium data of Cr(VI) adsorption onto vermiculite are best described by the Langmuir isotherm. The presence of hydrobiotite and biotite in the industrial vermiculite slightly decreased the degree of adsorption of Cr(VI). Copyright © 2012 Elsevier B.V. All rights reserved.

  10. Unilateral severe chronic periodontitis associated with ipsilateral surgical resection of cranial nerves V, VI, and VII.

    PubMed

    Zavarella, Matthew M; Leblebicioglu, Binnaz; Claman, Lewis J; Tatakis, Dimitris N

    2006-01-01

    The central and peripheral nervous systems participate in several local physiological and pathological processes. There is experimental evidence that the inflammatory, local immune, and wound healing responses of a tissue can be modulated by its innervation. The aim of this clinical report is to present a case of unilateral severe periodontitis associated with ipsilateral surgical resection of the fifth, sixth, and seventh cranial nerves and to discuss the possible contribution of the nervous system to periodontal pathogenesis. A 39-year-old female patient with a history of a cerebrovascular accident caused by a right pontine arteriovenous malformation and destruction of the right fifth, sixth, and seventh cranial nerves was diagnosed with severe chronic periodontitis affecting only the right maxillary and mandibular quadrants. The patient's oral hygiene was similar for right and left sides of the mouth. Percentages of tooth surfaces carrying dental plaque were 41% and 36% for right and left sides, respectively. Non-surgical and surgical periodontal therapy was performed, and the patient was placed on a regular periodontal maintenance schedule. Healing following initial periodontal therapy and osseous periodontal surgery occurred without complications. Follow-up clinical findings at 1 year revealed stable periodontal health. This case report suggests that periodontal innervation may contribute to the regulation of local processes involved in periodontitis pathogenesis. It also suggests that periodontal therapy can be performed successfully at sites and in patients affected by paralysis.

  11. One-stage posterior focus debridement, fusion, and instrumentation in the surgical treatment of lumbar spinal tuberculosis with kyphosis in children.

    PubMed

    Hu, Xiongke; Zhang, Hongqi; Yin, Xinhua; Chen, Yong; Yu, Honggui; Zhou, Zhenhai

    2016-03-01

    The purpose of this study is to investigate the clinical efficacy and feasibility of one-stage posterior focus debridement, fusion, and instrumentation in the surgical treatment of lumbar spinal tuberculosis with kyphosis in children. From December 2007 to May 2012, 13 patients (six males and seven females) suffering from lumbar spinal tuberculosis with kyphosis were admitted. All patients were treated with one-stage posterior focus debridement, fusion, and instrumentation. Then, the clinical efficacy was estimated by statistical analysis based on the data about Frankel grade, the Cobb angle of kyphosis, and erythrocyte sedimentation rate (ESR), which were collected at certain time. The age of all patients ranged from 5 to 13 years (average, 8.8 years). Operation time ranged from 120 to 190 min (average, 165 min). Intraoperative blood loss ranged from 200 to 800 ml (average, 460 ml). All patients were followed up for 24 to 57 months postoperatively (average, 33.5 months). The Cobb angle was changed significantly between preoperation and postoperation (P < 0.05), and there was no significant loss at the last follow-up. The preoperation ESR (62.5 ± 15.7) returned to normal (16.6 ± 8.1) within 3 months postoperatively in all patients (P < 0.05). Bone fusion was achieved within 3-5 months (average, 3.5 months). In the 13 cases, no postoperative severe complications occurred and neurologic function improved in various degrees. The outcomes of follow-up showed that one-stage posterior focus debridement, fusion, and instrumentation can be an effective treatment method for the lumbar spinal tuberculosis with kyphosis in children.

  12. [Implementation and evaluation of error prevention measures in surgical clinics: Results of a current online survey].

    PubMed

    Rothmund, Matthias; Kohlmann, Thomas; Heidecke, Claus-Dieter; Siebert, Hartmut; Ansorg, Jörg

    2015-01-01

    In the autumn of 2014, more than 3,000 surgeons completed an online questionnaire asking for the prevalence and efficiency of instruments to prevent adverse events within surgical departments in Germany. About 90 % of the respondents stated that perioperative checklists, preoperative marking of the surgical site and the documentation of hospital infections had been implemented in their institution; and 75 % of the institutions had introduced critical incident reporting systems (CIRS), morbidity and mortality conferences and identification bracelets for patients. The surgeons were asked to rank the different instruments for the prevention of adverse events. According to the respondents, preoperative marking of the surgical site and the use of checklists were at the top of the efficacy ranking, followed by an introductory course for surgeons starting work in a hospital or when new devices became available. Only 50 % of the responding surgeons perceived CIRS as being efficient. Overall, the answers showed that instruments to increase patient safety were commonly available in surgical departments. On the other hand, there is still room for improvement in daily practice. Copyright © 2015. Published by Elsevier GmbH.

  13. Cranial nerve VI palsy after dural-arachnoid puncture.

    PubMed

    Hofer, Jennifer E; Scavone, Barbara M

    2015-03-01

    In this article, we provide a literature review of cranial nerve (CN) VI injury after dural-arachnoid puncture. CN VI injury is rare and ranges in severity from diplopia to complete lateral rectus palsy with deviated gaze. The proposed mechanism of injury is cerebrospinal fluid leakage causing intracranial hypotension and downward displacement of the brainstem. This results in traction on CN VI leading to stretch and neural demyelination. Symptoms may present 1 day to 3 weeks after dural-arachnoid puncture and typically are associated with a postdural puncture (spinal) headache. Resolution of symptoms may take weeks to months. Use of small-gauge, noncutting spinal needles may decrease the risk of intracranial hypotension and subsequent CN VI injury. When ocular symptoms are present, early administration of an epidural blood patch may decrease morbidity or prevent progression of ocular symptoms.

  14. Vi-CRM 197 as a new conjugate vaccine against Salmonella Typhi.

    PubMed

    Micoli, F; Rondini, S; Pisoni, I; Proietti, D; Berti, F; Costantino, P; Rappuoli, R; Szu, S; Saul, A; Martin, L B

    2011-01-17

    An efficacious, low cost vaccine against typhoid fever, especially for young children, would make a major impact on disease burden in developing countries. The virulence capsular polysaccharide of Salmonella Typhi (Vi) coupled to recombinant mutant Pseudomonas aeruginosa exoprotein A (Vi-rEPA) has been shown to be highly efficacious. We investigated the use of carrier proteins included in infant vaccines, standardized the conjugation process and developed key assays required for routine lot release at production scale. Vi from a BSL1 organism, Citrobacter freundii, strain WR7011, was used as an alternative to Vi from S. Typhi. We showed that Vi conjugated to CRM(197), a non-toxic mutant of diphtheria toxin, widely used in commercial vaccines, was produced at high yield. Vi-CRM(197) proved immunogenic in animal studies, even without adjuvant. Thus, Vi-CRM(197) appears to be a suitable candidate for the development of a commercially viable, effective typhoid vaccine for developing countries. Copyright © 2010 Elsevier Ltd. All rights reserved.

  15. Consistency of performance of robot-assisted surgical tasks in virtual reality.

    PubMed

    Suh, I H; Siu, K-C; Mukherjee, M; Monk, E; Oleynikov, D; Stergiou, N

    2009-01-01

    The purpose of this study was to investigate consistency of performance of robot-assisted surgical tasks in a virtual reality environment. Eight subjects performed two surgical tasks, bimanual carrying and needle passing, with both the da Vinci surgical robot and a virtual reality equivalent environment. Nonlinear analysis was utilized to evaluate consistency of performance by calculating the regularity and the amount of divergence in the movement trajectories of the surgical instrument tips. Our results revealed that movement patterns for both training tasks were statistically similar between the two environments. Consistency of performance as measured by nonlinear analysis could be an appropriate methodology to evaluate the complexity of the training tasks between actual and virtual environments and assist in developing better surgical training programs.

  16. Video-Based Method of Quantifying Performance and Instrument Motion During Simulated Phonosurgery

    PubMed Central

    Conroy, Ellen; Surender, Ketan; Geng, Zhixian; Chen, Ting; Dailey, Seth; Jiang, Jack

    2015-01-01

    Objectives/Hypothesis To investigate the use of the Video-Based Phonomicrosurgery Instrument Tracking System to collect instrument position data during simulated phonomicrosurgery and calculate motion metrics using these data. We used this system to determine if novice subject motion metrics improved over 1 week of training. Study Design Prospective cohort study. Methods Ten subjects performed simulated surgical tasks once per day for 5 days. Instrument position data were collected and used to compute motion metrics (path length, depth perception, and motion smoothness). Data were analyzed to determine if motion metrics improved with practice time. Task outcome was also determined each day, and relationships between task outcome and motion metrics were used to evaluate the validity of motion metrics as indicators of surgical performance. Results Significant decreases over time were observed for path length (P <.001), depth perception (P <.001), and task outcome (P <.001). No significant change was observed for motion smoothness. Significant relationships were observed between task outcome and path length (P <.001), depth perception (P <.001), and motion smoothness (P <.001). Conclusions Our system can estimate instrument trajectory and provide quantitative descriptions of surgical performance. It may be useful for evaluating phonomicrosurgery performance. Path length and depth perception may be particularly useful indicators. PMID:24737286

  17. Forensic investigation of a chromium(VI) groundwater plume in Thiva, Greece.

    PubMed

    Panagiotakis, I; Dermatas, D; Vatseris, C; Chrysochoou, M; Papassiopi, N; Xenidis, A; Vaxevanidou, K

    2015-01-08

    A forensic investigation was conducted with the aim of decoupling the contribution of geogenic and anthropogenic Cr(VI) sources in the wider area of Thiva. Groundwater and topsoil samples were collected from two Cr(VI) groundwater plumes of 160 μg/L and 75 μg/L. A series of evidence support the view that the origin of Cr(VI) detected in groundwater is mainly geogenic. These are: (a) the presence of Cr in topsoil of the wider area, (b) the moderate Cr(VI) groundwater concentrations, (c) the high Ni levels within the Cr(VI) plumes, (d) the predominance of Mn(IV), which is a prerequisite for Cr(III) oxidation to Cr(VI), and (e) the absence of co-contaminants. The present study also revealed that, although both Cr(VI) plumes are clearly of geogenic origin, the plume with the elevated Cr(VI) values, in the north of Thiva town, exhibits also an anthropogenic component, which can potentially be attributed to the alkaline environment associated with the old uncontrolled landfill of Thiva and the industrial cluster located in this area. Copyright © 2014 Elsevier B.V. All rights reserved.

  18. Influence of Calcium on Microbial Reduction of Solid Phase Uranium (VI)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, Chongxuan; Jeon, Byong-Hun; Zachara, John M.

    2007-06-27

    The effect of calcium on microbial reduction of a solid phase U(VI), sodium boltwoodite (NaUO2SiO3OH ∙1.5H2O), was evaluated in a culture of a dissimilatory metal-reducing bacterium (DMRB), Shewanella oneidensis strain MR-1. Batch experiments were performed in a non-growth bicarbonate medium with lactate as electron donor at pH 7 buffered with PIPES. Calcium increased both the rate and extent of Na-boltwoodite dissolution by increasing its solubility through the formation of a ternary aqueous calcium-uranyl-carbonate species. The ternary species, however, decreased the rates of microbial reduction of aqueous U(VI). Laser-induced fluorescence spectroscopy (LIFS) and transmission electron microscopy (TEM) revealed that microbial reductionmore » of solid phase U(VI) is a sequentially coupled process of Na-boltwoodite dissolution, U(VI) aqueous speciation, and microbial reduction of dissolved U(VI) to U(IV) that accumulated on bacterial surfaces/periplasm. The overall rates of microbial reduction of solid phase U(VI) can be described by the coupled rates of dissolution and microbial reduction that were both influenced by calcium. The results demonstrated that dissolved U(VI) concentration during microbial reduction was a complex function of solid phase U(VI) dissolution kinetics, aqueous U(VI) speciation, and microbial activity.« less

  19. Study of Individual Characteristic Abdominal Wall Thickness Based on Magnetic Anchored Surgical Instruments

    PubMed Central

    Dong, Ding-Hui; Liu, Wen-Yan; Feng, Hai-Bo; Fu, Yi-Li; Huang, Shi; Xiang, Jun-Xi; Lyu, Yi

    2015-01-01

    Background: Magnetic anchored surgical instruments (MASI), relying on magnetic force, can break through the limitations of the single port approach in dexterity. Individual characteristic abdominal wall thickness (ICAWT) deeply influences magnetic force that determines the safety of MASI. The purpose of this study was to research the abdominal wall characteristics in MASI applied environment to find ICAWT, and then construct an artful method to predict ICAWT, resulting in better safety and feasibility for MASI. Methods: For MASI, ICAWT is referred to the thickness of thickest point in the applied environment. We determined ICAWT through finding the thickest point in computed tomography scans. We also investigated the traits of abdominal wall thickness to discover the factor that can be used to predict ICAWT. Results: Abdominal wall at C point in the middle third lumbar vertebra plane (L3) is the thickest during chosen points. Fat layer thickness plays a more important role in abdominal wall thickness than muscle layer thickness. “BMI-ICAWT” curve was obtained based on abdominal wall thickness of C point in L3 plane, and the expression was as follow: f(x) = P1 × x2 + P2 × x + P3, where P1 = 0.03916 (0.01776, 0.06056), P2 = 1.098 (0.03197, 2.164), P3 = −18.52 (−31.64, −5.412), R-square: 0.99. Conclusions: Abdominal wall thickness of C point at L3 could be regarded as ICAWT. BMI could be a reliable predictor of ICAWT. In the light of “BMI-ICAWT” curve, we may conveniently predict ICAWT by BMI, resulting a better safety and feasibility for MASI. PMID:26228215

  20. Building a framework for ergonomic research on laparoscopic instrument handles.

    PubMed

    Li, Zheng; Wang, Guohui; Tan, Juan; Sun, Xulong; Lin, Hao; Zhu, Shaihong

    2016-06-01

    Laparoscopic surgery carries the advantage of minimal invasiveness, but ergonomic design of the instruments used has progressed slowly. Previous studies have demonstrated that the handle of laparoscopic instruments is vital for both surgical performance and surgeon's health. This review provides an overview of the sub-discipline of handle ergonomics, including an evaluation framework, objective and subjective assessment systems, data collection and statistical analyses. Furthermore, a framework for ergonomic research on laparoscopic instrument handles is proposed to standardize work on instrument design. Copyright © 2016 IJS Publishing Group Ltd. Published by Elsevier Ltd. All rights reserved.

  1. Singular Instantons and Painlevé VI

    NASA Astrophysics Data System (ADS)

    Muñiz Manasliski, Richard

    2016-06-01

    We consider a two parameter family of instantons, which is studied in [Sadun L., Comm. Math. Phys. 163 (1994), 257-291], invariant under the irreducible action of SU_2 on S^4, but which are not globally defined. We will see that these instantons produce solutions to a one parameter family of Painlevé VI equations (P_VI}) and we will give an explicit expression of the map between instantons and solutions to P_{VI}. The solutions are algebraic only for that values of the parameters which correspond to the instantons that can be extended to all of S^4. This work is a generalization of [Muñiz Manasliski R., Contemp. Math., Vol. 434, Amer. Math. Soc., Providence, RI, 2007, 215-222] and [Muñiz Manasliski R., J. Geom. Phys. 59 (2009), 1036-1047, arXiv:1602.07221], where instantons without singularities are studied.

  2. Formic acid interaction with the uranyl(VI) ion: structural and photochemical characterization.

    PubMed

    Lucks, Christian; Rossberg, André; Tsushima, Satoru; Foerstendorf, Harald; Fahmy, Karim; Bernhard, Gert

    2013-10-07

    Complex formation between the uranyl(VI) ion and formic acid was studied by infrared absorption (IR) and X-ray absorption (EXAFS) spectroscopy as well as density functional theory (DFT) calculations. In contrast to the acetate ion which forms exclusively a bidentate complex with uranyl(VI), the formate ion binds to uranyl(VI) in a unidentate fashion. The photochemistry of the uranyl(VI)-formic acid system was explored by DFT calculations and photoreduction of uranyl(VI) in the presence of formic acid was found to occur via an intermolecular process, that is, hydrogen abstraction from hydrogenformate by the photo-excited uranyl(VI). There is no photo-induced decarboxylation of uranyl(VI) formate via an intramolecular process, presumably due to lack of a C=C double bond.

  3. U(VI) adsorption on aquifer sediments at the Hanford Site.

    PubMed

    Um, Wooyong; Serne, R Jeffrey; Brown, Christopher F; Last, George V

    2007-08-15

    Aquifer sediments collected via split-spoon sampling in two new groundwater wells in the 200-UP-1 operable unit at the Hanford Site were characterized and showed typical Ringold Unit E Formation properties dominated by gravel and sand. High iron-oxide content in Fe oxide/clay coatings caused the highest U(VI) adsorption as quantified by batch K(d) values, indicating iron oxides are the key solid adsorbent in the 200-UP-1 sediments that affect U(VI) fate and mobility. Even though U(VI) adsorption on the gravel-sized fraction of the sediments is considered to be negligible, careful characterization should be conducted to determine U(VI) adsorption on gravel, because of presence of Fe oxides coatings and diffusion-controlled adsorption into the gravel particles' interior surfaces. A linear adsorption isotherm was observed up to 10(-6) M (238 microg/L) of total U(VI) concentration in batch U(VI) adsorption tests with varying total U(VI) concentrations in spiked groundwater. U(VI) adsorption decreased with increasing concentrations of dissolved carbonate, because strong anionic aqueous uranium-carbonate complexes formed at high pH and high alkalinity conditions. Noticeable uranium desorption hysteresis was observed in a flow-through column experiment, suggesting that desorption K(d) values for aged uranium-contaminated sediments at the Hanford Site can be larger than adsorption K(d) values determined in short-term laboratory experiments and slow uranium release from contaminated sediments into the groundwater is expected.

  4. Instrumentation Failure after Partial Corpectomy with Instrumentation of a Metastatic Spine.

    PubMed

    Park, Sung Bae; Kim, Ki Jeong; Han, Sanghyun; Oh, Sohee; Kim, Chi Heon; Chung, Chun Kee

    2018-05-01

    To identify the perioperative factors associated with instrument failure in patients undergoing a partial corpectomy with instrumentation (PCI) for spinal metastasis. We assessed the one hundred twenty-four patients with who underwent PCI for a metastatic spine from 1987 to 2011. Outcome measure was the risk factor related to implantation failure. The preoperative factors analyzed were age, sex, ambulation, American Spinal Injury Association grade, bone mineral density, use of steroid, primary tumor site, number of vertebrae with metastasis, extra-bone metastasis, preoperative adjuvant chemotherapy, and preoperative spinal radiotherapy. The intraoperative factors were the number of fixed vertebrae, fixation in osteolytic vertebrae, bone grafting, and type of surgical approach. The postoperative factors included postoperative adjuvant chemotherapy and spinal radiotherapy. This study was supported by the National Research Foundation grant funded by government. There were no study-specific biases related to conflicts of interest. There were 15 instrumentation failures (15/124, 12.1%). Preoperative ambulatory status and primary tumor site were not significantly related to the development of implant failure. There were no significant associations between insertion of a bone graft into the partial corpectomy site and instrumentation failure. The preoperative and operative factors analyzed were not significantly related to instrumentation failure. In univariable and multivariable analyses, postoperative spinal radiotherapy was the only significant variable related to instrumentation failure ( p =0.049 and 0.050, respectively). When performing PCI in patients with spinal metastasis followed by postoperative spinal radiotherapy, the surgeon may consider the possibility of instrumentation failure and find other strategies for augmentation than the use of a bone graft for fusion.

  5. 21 CFR 882.4535 - Nonpowered neurosurgical instrument.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Nonpowered neurosurgical instrument. 882.4535 Section 882.4535 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4535 Nonpowered...

  6. 21 CFR 882.4535 - Nonpowered neurosurgical instrument.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Nonpowered neurosurgical instrument. 882.4535 Section 882.4535 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4535 Nonpowered...

  7. Remediation of Cr(VI)-Contaminated Soil Using the Acidified Hydrazine Hydrate.

    PubMed

    Ma, Yameng; Li, Fangfang; Jiang, Yuling; Yang, Weihua; Lv, Lv; Xue, Haotian; Wang, Yangyang

    2016-09-01

    Acidified hydrazine hydrate was used to remediate Cr(VI)-contaminated soil. The content of water-soluble Cr(VI) in contaminated soil was 4977.53 mg/kg. The optimal initial pH of hydrazine hydrate solution, soil to solution ratio and molar ratio of Cr(VI) to hydrazine hydrate for remediation of Cr(VI)-contaminated soil were 5.0, 3:1 and 1:3, respectively. Over 99.50 % of water-soluble Cr(VI) in the contaminated soil was reduced at the optimal condition within 30 min. The remediated soil can keep stable within 4 months. Meanwhile the total phosphorus increased from 0.47 to 4.29 g/kg, indicating that using of acidified hydrazine hydrate is an effective method to remediate Cr(VI)-contaminated soil.

  8. Detection and Persistence of Vi Antigen in Tissues of Actively Immunized Mice1

    PubMed Central

    Gaines, Sidney; Currie, Julius A.; Tully, Joseph G.

    1965-01-01

    Gaines, Sidney (Walter Reed Army Institute of Research, Washington, D.C.), Julius A. Currie, and Joseph G. Tully. Detection and persistence of Vi antigen in tissues of actively immunized mice. J. Bacteriol. 89:776–781. 1965.—The presence, distribution, and persistence of Vi antigen in mouse tissue was determined by means of active immunization tests with tissue extracts. Mice were injected intraperitoneally with purified Vi antigen or Vi-containing bacilli. At appropriate intervals, animals were killed, and saline extracts of their tissues were prepared. Mice were immunized with these extracts and challenged 6 days later with 10 ld50 of Salmonella typhosa Ty2. Protection was afforded by tissue extracts from Vi-injected mice, but not by normal tissue extracts. That the immunizing capacity of tissue extracts from Vi-injected mice was attributable to Vi antigen was affirmed by the demonstration that these extracts stimulated the production of Vi antibody in mice, coated erythrocytes for agglutination by Vi antiserum, and inhibited agglutination of Vi-sensitized red blood cells by known Vi antisera. Vi antigen could be detected in the liver and spleen of mice injected with as little as 1 μg. In mice given 150 μg, the antigen was still present in liver tissue 231 days later. PMID:14273660

  9. Comparison of impact of four surgical methods on surgical outcomes in endoscopic dacryocystorhinostomy.

    PubMed

    Roh, Hyun Cheol; Baek, Sehyun; Lee, Hwa; Chang, Minwook

    2016-06-01

    To evaluate differences in the surgical outcomes of endoscopic dacryocystorhinostomy (DCR) according to four different surgical methods. This retrospective study included 222 patients who underwent endoscopic DCR from 2011 to 2013. All patients were assigned to one of four groups according to instruments for incision of nasal mucosa and the formation of mucosal flap: group 1, a sickle knife with mucosal flap; group 2, a sickle knife without mucosal flap; group 3, electrocautery with mucosal flap; and group 4, electrocautery without mucosal flap. The follow up period was at least 6 months. There were 33 eyes in group 1, 44 eyes in group 2, 49 eyes in group 3, and 97 eyes in group 4. There were no significant differences in success rate between groups (P = 0.878). Wound healing time was significantly different between groups (P < 0.001). In post hoc analysis, wound healing time was significantly shorter in group 1 and group 2 than in group 3 and group 4. The vertical ostium size and postsurgical complication were not significantly different between groups. The use of cold instruments such as sickle knife may be more helpful and effective for shortening wound healing time rather than making mucosal flaps in endoscopic DCR. Copyright © 2016 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  10. Current Limitations of Surgical Robotics in Reconstructive Plastic Microsurgery.

    PubMed

    Tan, Youri P A; Liverneaux, Philippe; Wong, Jason K F

    2018-01-01

    Surgical robots have the potential to provide surgeons with increased capabilities, such as removing physiologic tremor, scaling motion and increasing manual dexterity. Several surgical specialties have subsequently integrated robotic surgery into common clinical practice. Plastic and reconstructive microsurgical procedures have not yet  benefitted significantly from technical developments observed over the last two decades. Several studies have successfully demonstrated the feasibility of utilising surgical robots in plastic surgery procedures, yet limited work has been done to identify and analyse current barriers that have prevented wide-scale adaptation of surgical robots for microsurgery. Therefore, a systematic review using PubMed, MEDLINE, Embase and Web of Science databases was performed, in order to evaluate current state of surgical robotics within the field of reconstructive microsurgery and their limitations. Despite the theoretical potential of surgical robots, current commercially available robotic systems are suboptimal for plastic or reconstructive microsurgery. Absence of bespoke microsurgical instruments, increases in operating time, and high costs associated with robotic-assisted provide a barrier to using such systems effectively for reconstructive microsurgery. Consequently, surgical robots provide currently little overall advantage over conventional microsurgery. Nevertheless, if current barriers can be addressed and systems are specifically designed for microsurgery, surgical robots may have the potential of meaningful impact on clinical outcomes within  this surgical subspeciality.

  11. Simultaneous Cr(VI) bio-reduction and methane production by anaerobic granular sludge.

    PubMed

    Hu, Qian; Sun, Jiaji; Sun, Dezhi; Tian, Lan; Ji, Yanan; Qiu, Bin

    2018-08-01

    Wastewater containing toxic hexavalent chromium (Cr(VI)) were treated with well-organized anaerobic granular sludge in this study. Results showed that the anaerobic granular sludge rapidly removed Cr(VI), and 2000 µg·L -1 Cr(VI) was completely eliminated within 6 min, which was much faster than the reported duration of removal by reported artificial materials. Sucrose added as a carbon source acted as an initial electron donor to reduce Cr(VI) to Cr(III). This process was considered as the main mechanism of Cr(VI) removal. Methane production by anaerobic granular sludge was improved by the addition of Cr(VI) at a concentration lower than 500 µg·L -1 . Anaerobic granular sludge had a well-organized structure, which presented good resistance against toxic Cr(VI). Trichoccus accelerated the degradation of organic substances to generate acetates with a low Cr(VI) concentration, thereby enhancing methane production by acetotrophic methanogens. Copyright © 2018 Elsevier Ltd. All rights reserved.

  12. Re-examination of immune response and estimation of anti-Vi IgG protective threshold against typhoid fever-based on the efficacy trial of Vi conjugate in young children.

    PubMed

    Szu, Shousun C; Klugman, Keith P; Hunt, Steven

    2014-04-25

    The capsular polysaccharide of Salmonella enterica serovar Typhi, Vi antigen, is an essential virulence factor and a protective antigen. Similar to other polysaccharide vaccines, the protective action of Vi, both to the polysaccharide alone or when presented as a conjugate, is mediated by serum IgG Vi antibodies. The evaluation of Vi capsular polysaccharide based vaccines to prevent typhoid fever would be significantly facilitated by the identification of a "protective level" of serum antibodies to Vi antigen. The protective level of anti-Vi IgG against typhoid fever was derived from the protective efficacy and immune response of a Vi-rEPA conjugate vaccine efficacy trial. The estimation was derived by two methods: correlation of the percent efficacy and the antibody distribution profile in the vaccine group at a given period of observation, and use of the relative ratio of anti-Vi IgG levels between the vaccine and placebo groups greater or equal to the Relative Risk of typhoid fever used in the efficacy determination. Both methods predicted a similar range of a minimum protective level of anti-Vi IgG between 1.4 and 2.0μg/ml (short term threshold). When applying a protective threshold of 10μg/ml at 6 months post immunization, an IgG level in excess of 1.4μg/ml was achieved by 90% of children at 46 months post immunization, consistent with an 89% level of protection over the duration of the study. We thus suggest that the proportion of children with Vi IgG>10μg/ml (long term threshold) 6 months after immunization may reflect the proportion protected over at least a 4 year period. The current assignment of an anti-Vi IgG protective level may be of value when evaluating vaccine performance of future Vi conjugate vaccines. Published by Elsevier Ltd.

  13. Re-examination of immune response and estimation of anti-Vi IgG protective threshold against typhoid fever-based on the efficacy trial of Vi conjugate in young children

    PubMed Central

    Szu, Shousun C.; Klugman, Keith P.; Hunt, Steven

    2014-01-01

    Background The capsular polysaccharide of Salmonella enterica serovar Typhi, Vi antigen, is an essential virulence factor and a protective antigen. Similar to other polysaccharide vaccines, the protective action of Vi, both to the polysaccharide alone or when presented as a conjugate, is mediated by serum IgG Vi antibodies. The evaluation of Vi capsular polysaccharide based vaccines to prevent typhoid fever would be significantly facilitated by the identification of a “protective level” of serum antibodies to Vi antigen. Methods The protective level of anti-Vi IgG against typhoid fever was derived from the protective efficacy and immune response of a Vi-rEPA conjugate vaccine efficacy trial. The estimation was derived by two methods: correlation of the percent efficacy and the antibody distribution profile in the vaccine group at a given period of observation, and use of the relative ratio of anti-Vi IgG levels between the vaccine and placebo groups greater or equal to the Relative Risk of typhoid fever used in the efficacy determination. Results Both methods predicted a similar range of a minimum protective level of anti-Vi IgG between 1.4 and 2.0 μg/ml (short term threshold). When applying a protective threshold of 10 μg/ml at 6 months post immunization, an IgG level in excess of 1.4 μg/ml was achieved by 90% of children at 46 months post immunization, consistent with an 89% level of protection over the duration of the study. We thus suggest that the proportion of children with Vi IgG > 10 μg/ml (long term threshold) 6 months after immunization may reflect the proportion protected over at least a 4 year period. Conclusion The current assignment of an anti-Vi IgG protective level may be of value when evaluating vaccine performance of future Vi conjugate vaccines. PMID:24630869

  14. Review of emerging surgical robotic technology.

    PubMed

    Peters, Brian S; Armijo, Priscila R; Krause, Crystal; Choudhury, Songita A; Oleynikov, Dmitry

    2018-04-01

    The use of laparoscopic and robotic procedures has increased in general surgery. Minimally invasive robotic surgery has made tremendous progress in a relatively short period of time, realizing improvements for both the patient and surgeon. This has led to an increase in the use and development of robotic devices and platforms for general surgery. The purpose of this review is to explore current and emerging surgical robotic technologies in a growing and dynamic environment of research and development. This review explores medical and surgical robotic endoscopic surgery and peripheral technologies currently available or in development. The devices discussed here are specific to general surgery, including laparoscopy, colonoscopy, esophagogastroduodenoscopy, and thoracoscopy. Benefits and limitations of each technology were identified and applicable future directions were described. A number of FDA-approved devices and platforms for robotic surgery were reviewed, including the da Vinci Surgical System, Sensei X Robotic Catheter System, FreeHand 1.2, invendoscopy E200 system, Flex® Robotic System, Senhance, ARES, the Single-Port Instrument Delivery Extended Research (SPIDER), and the NeoGuide Colonoscope. Additionally, platforms were reviewed which have not yet obtained FDA approval including MiroSurge, ViaCath System, SPORT™ Surgical System, SurgiBot, Versius Robotic System, Master and Slave Transluminal Endoscopic Robot, Verb Surgical, Miniature In Vivo Robot, and the Einstein Surgical Robot. The use and demand for robotic medical and surgical platforms is increasing and new technologies are continually being developed. New technologies are increasingly implemented to improve on the capabilities of previously established systems. Future studies are needed to further evaluate the strengths and weaknesses of each robotic surgical device and platform in the operating suite.

  15. Online time and resource management based on surgical workflow time series analysis.

    PubMed

    Maktabi, M; Neumuth, T

    2017-02-01

    Hospitals' effectiveness and efficiency can be enhanced by automating the resource and time management of the most cost-intensive unit in the hospital: the operating room (OR). The key elements required for the ideal organization of hospital staff and technical resources (such as instruments in the OR) are an exact online forecast of both the surgeon's resource usage and the remaining intervention time. This paper presents a novel online approach relying on time series analysis and the application of a linear time-variant system. We calculated the power spectral density and the spectrogram of surgical perspectives (e.g., used instrument) of interest to compare several surgical workflows. Considering only the use of the surgeon's right hand during an intervention, we were able to predict the remaining intervention time online with an error of 21 min 45 s ±9 min 59 s for lumbar discectomy. Furthermore, the performance of forecasting of technical resource usage in the next 20 min was calculated for a combination of spectral analysis and the application of a linear time-variant system (sensitivity: 74 %; specificity: 75 %) focusing on just the use of surgeon's instrument in question. The outstanding benefit of these methods is that the automated recording of surgical workflows has minimal impact during interventions since the whole set of surgical perspectives need not be recorded. The resulting predictions can help various stakeholders such as OR staff and hospital technicians. Moreover, reducing resource conflicts could well improve patient care.

  16. Oxidation of Oil Sands Process-Affected Water by Potassium Ferrate(VI).

    PubMed

    Wang, Chengjin; Klamerth, Nikolaus; Huang, Rongfu; Elnakar, Haitham; Gamal El-Din, Mohamed

    2016-04-19

    This paper investigates the oxidation of oil sands process-affected water (OSPW) by potassium ferrate(VI). Due to the selectivity of ferrate(VI) oxidation, two-ring and three-ring fluorescing aromatics were preferentially removed at doses <100 mg/L Fe(VI), and one-ring aromatics were removed only at doses ≥100 mg/L Fe(VI). Ferrate(VI) oxidation achieved 64.0% and 78.4% removal of naphthenic acids (NAs) at the dose of 200 mg/L and 400 mg/L Fe(VI) respectively, and NAs with high carbon number and ring number were removed preferentially. (1)H nuclear magnetic resonance ((1)H NMR) spectra indicated that the oxidation of fluorescing aromatics resulted in the opening of some aromatic rings. Electron paramagnetic resonance (EPR) analysis detected signals of organic radical intermediates, indicating that one-electron transfer is one of the probable mechanisms in the oxidation of NAs. The inhibition effect of OSPW on Vibrio fischeri and the toxicity effect on goldfish primary kidney macrophages (PKMs) were both reduced after ferrate(VI) oxidation. The fluorescing aromatics in OSPW were proposed to be an important contributor to this acute toxicity. Degradation of model compounds with ferrate(VI) was also investigated and the results confirmed our findings in OSPW study.

  17. Instrumentation of Near-term Fetal Sheep for Multivariate Chronic Non-anesthetized Recordings

    PubMed Central

    Burns, Patrick; Liu, Hai Lun; Kuthiala, Shikha; Fecteau, Gilles; Desrochers, André; Durosier, Lucien Daniel; Cao, Mingju; Frasch, Martin G.

    2015-01-01

    The chronically instrumented pregnant sheep has been used as a model of human fetal development and responses to pathophysiologic stimuli such as endotoxins, bacteria, umbilical cord occlusions, hypoxia and various pharmacological treatments. The life-saving clinical practices of glucocorticoid treatment in fetuses at risk of premature birth and the therapeutic hypothermia have been developed in this model. This is due to the unique amenability of the non-anesthetized fetal sheep to the surgical placement and maintenance of catheters and electrodes, allowing repetitive blood sampling, substance injection, recording of bioelectrical activity, application of electric stimulation and in vivo organ imaging. Here we describe the surgical instrumentation procedure required to achieve a stable chronically instrumented non-anesthetized fetal sheep model including characterization of the post-operative recovery from blood gas, metabolic and inflammation standpoints. PMID:26555084

  18. Sorption characteristic of uranium(VI) ion onto K-feldspar.

    PubMed

    Gao, Xiaoqing; Bi, Mingliang; Shi, Keliang; Chai, Zhifang; Wu, Wangsuo

    2017-10-01

    The effect of pH, contact time, temperature, ionic strength and initial U(VI) concentration on U(VI) sorption onto K-feldspar was investigated using batch techniques. The sorption kinetics was evaluated and the activation energy was obtained based on the rate constants at different temperature. Graphical correlations of sorption isotherm models have been evaluated and applied for U(VI) uptake by K-feldspar. Various thermodynamic parameters, such as, Gibb's free energy, entropy and enthalpy of the on-going sorption process have been calculated and the possible sorption mechanism of U(VI) was deduced. The results are expected to help better understand the migration of uranium in the host materials of granite. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Microstructural analyses of Cr(VI) speciation in chromite ore processing Residue (COPR)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    CHRYSOCHOOU, MARIA; FAKRA, SIRINE C .; Marcus, Matthew A.

    2010-03-01

    The speciation and distribution of Cr(VI) in the solid phase was investigated for two types of chromite ore processing residue (COPR) found at two deposition sites in the United States: gray-black (GB) granular and hard brown (HB) cemented COPR. COPR chemistry and mineralogy were investigated using micro-X-ray absorption spectroscopy and micro-X-ray diffraction, complemented by laboratory analyses. GB COPR contained 30percent of its total Cr(VI) (6000 mg/kg) as large crystals(>20 ?m diameter) of a previously unreported Na-rich analog of calcium aluminum chromate hydrates. These Cr(VI)-rich phases are thought to be vulnerable to reductive and pH treatments. More than 50percent of themore » Cr(VI) was located within nodules, not easily accessible to dissolved reductants, and bound to Fe-rich hydrogarnet, hydrotalcite, and possibly brucite. These phases are stable over a large pH range, thus harder to dissolve. Brownmilleritewasalso likely associated with physical entrapment of Cr(VI) in the interior of nodules. HB COPR contained no Cr(VI)-rich phases; all Cr(VI) was diffuse within the nodules and absent from the cementing matrix, with hydrogarnet and hydrotalcite being the main Cr(VI) binding phases. Treatment ofHBCOPRis challenging in terms of dissolving the acidity-resistant, inaccessible Cr(VI) compounds; the same applies to ~;;50percent of Cr(VI) in GB COPR.« less

  20. Early intervention to promote medical student interest in surgery and the surgical subspecialties.

    PubMed

    Patel, Madhukar S; Mowlds, Donald S; Khalsa, Bhavraj; Foe-Parker, Jennifer E; Rama, Asheen; Jafari, Fariba; Whealon, Matthew D; Salibian, Ara; Hoyt, David B; Stamos, Michael J; Endres, Jill E; Smith, Brian R

    2013-01-01

    Concerns about projected workforce shortages are growing, and attrition rates among surgical residents remain high. Early exposure of medical students to the surgical profession may promote interest in surgery and allow students more time to make informed career decisions. The objective of this study was to evaluate the impact of a simple, easily reproducible intervention aimed at increasing first- and second-year medical student interest in surgery. Surgery Saturday (SS) is a student-organized half-day intervention of four faculty-led workshops that introduce suturing, knot tying, open instrument identification, operating room etiquette, and basic laparoscopic skills. Medical students who attended SS were administered pre-/post-surveys that gauged change in surgical interest levels and provided a self-assessment (1-5 Likert-type items) of knowledge and skills acquisition. First- and second-year medical students. Change in interest in the surgical field as well as perceived knowledge and skills acquisition. Thirty-three first- and second-year medical students attended SS and completed pre-/post-surveys. Before SS, 14 (42%) students planned to pursue a surgical residency, 4 (12%) did not plan to pursue a surgical residency, and 15 (46%) were undecided. At the conclusion, 29 (88%) students indicated an increased interested in surgery, including 87% (13/15) who were initially undecided. Additionally, attendees reported a significantly (p < 0.05) higher comfort level in the following: suturing, knot tying, open instrument identification, operating room etiquette, and laparoscopic instrument identification and manipulation. SS is a low resource, high impact half-day intervention that can significantly promote early medical student interest in surgery. As it is easily replicable, adoption by other medical schools is encouraged. Copyright © 2012 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  1. 76 FR 62148 - Title VI; Proposed Circular, Environmental Justice; Proposed Circular

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-10-06

    ...-0055] Title VI; Proposed Circular, Environmental Justice; Proposed Circular AGENCY: Federal Transit... the September 29, 2011, Federal Register Notices titled ``Title VI; Proposed Circular'' and... September 29, 2011, Federal Register Notices titled ``Title VI; Proposed Circular'' (76 FR 60593) and...

  2. [Application of virtual instrumentation technique in toxicological studies].

    PubMed

    Moczko, Jerzy A

    2005-01-01

    Research investigations require frequently direct connection of measuring equipment to the computer. Virtual instrumentation technique considerably facilitates programming of sophisticated acquisition-and-analysis procedures. In standard approach these two steps are performed subsequently with separate software tools. The acquired data are transfered with export / import procedures of particular program to the another one which executes next step of analysis. The described procedure is cumbersome, time consuming and may be potential source of the errors. In 1987 National Instruments Corporation introduced LabVIEW language based on the concept of graphical programming. Contrary to conventional textual languages it allows the researcher to concentrate on the resolved problem and omit all syntactical rules. Programs developed in LabVIEW are called as virtual instruments (VI) and are portable among different computer platforms as PCs, Macintoshes, Sun SPARCstations, Concurrent PowerMAX stations, HP PA/RISK workstations. This flexibility warrants that the programs prepared for one particular platform would be also appropriate to another one. In presented paper basic principles of connection of research equipment to computer systems were described.

  3. Measuring patient participation in surgical treatment decision-making from healthcare professionals' perspective.

    PubMed

    Heggland, Liv-Helen; Mikkelsen, Aslaug; Øgaard, Torvald; Hausken, Kjell

    2014-02-01

    To develop, empirical test, and validate an instrument measuring patient participation in surgical treatment decision-making from healthcare professionals' perspective. Since the advent of New Public Management in many Western countries, patient participation in healthcare decision-making has been considered to be a best practice. A common notion is that well-educated and well-informed public want to choose their own treatments and providers and want to ask questions about the quality of their health services. Survey. A self-report-measuring instrument was designed and administered to 620 healthcare professionals. Items were developed, validated and tested by 451 nurses and physicians working in six surgical wards in a University Hospital in Norway. A 16-item scale with the following four dimensions was developed: information dissemination, formulation of options, integration of information and control. Factor analysis procedures and reliability testing were performed. A one-way, between-groups analysis of variance was conducted to compare doctors' and nurses' opinions on four dimensions of patient participation in surgical treatment decision-making. This article shows that patient participation in surgical treatment decision-making can be measured by a 16-item scale and four distinct dimensions. The analysis demonstrated a reasonable level of construct validity and reliability. Nurses and physicians have a positive attitude towards patient participation overall, but the two groups differ in the extent to which they accept the idea of patient participation in treatment decision-making. The instrument can be a tool for managers and healthcare professionals in the implementation of patient participation in clinical practice. Data from the instrument can be useful to identify health services being provided and what areas that could strengthen patient participation. © 2013 Blackwell Publishing Ltd.

  4. Synthesis of surface Cr (VI)-imprinted magnetic nanoparticles for selective dispersive solid-phase extraction and determination of Cr (VI) in water samples.

    PubMed

    Qi, Xue; Gao, Shuang; Ding, Guosheng; Tang, An-Na

    2017-01-01

    A facile, rapid and selective magnetic dispersed solid-phase extraction (dSPE) method for the extraction and enrichment of Cr (VI) prior to flame atomic absorption spectrometry (AAS) was introduced. For highly selective and efficient extraction, magnetic Cr (VI)-imprinted nanoparticles (Fe 3 O 4 @ Cr (VI) IIPs) were prepared by hyphenating surface ion-imprinted with sol-gel techniques. In the preparation process, chromate (Cr(VI)) was used as the template ion; vinylimidazole and 3-aminopropyltriethoxysilane were selected as organic functional monomer and co-monomer respectively. Another reagent, methacryloxypropyltrimethoxysilane was adopted as coupling agent to form the stable covalent bonding between organic and inorganic phases. The effects of various parameters on the extraction efficiency, such as pH of sample solution, the amount of adsorbent, extraction time, the type and concentration of eluent were systematically investigated. Furthermore, the thermodynamic and kinetic properties of the adsorption process were studied to explore the internal adsorption mechanism. Under optimized conditions, the preconcentration factor, limit of detection and linear range of the established dSPE-AAS method for Cr (VI) were found to be 98, 0.29μgL -1 and 4-140μgL -1 , respectively. The developed method was also successfully applied to the analysis of Cr (VI) in different water samples with satisfactory results, proving its reliability and feasibility in real sample analysis. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. Ferrate(VI) oxidation of weak-acid dissociable cyanides

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ria A. Yngard; Virender K. Sharma; Jan Filip

    2008-04-15

    Cyanide is commonly found in electroplating, mining, coal gasification, and petroleum refining effluents, which require treatment before being discharged. Cyanide in effluents exists either as free cyanide or as a metal complex. The kinetics of the oxidation of weak-acid dissociable cyanides by an environmentally friendly oxidant, ferrate, were studied as a function of pH (9.1-10.5) and temperature (15-45{sup o}C) using a stopped-flow technique. The weak-acid dissociable cyanides were Cd(CN){sub 4}{sup 2-} and Ni(CN){sub 4}{sup 2-}, and the rate-laws for the oxidation may be -d(Fe(VI))/dt = k (Fe(VI))(M(CN){sub 4}{sup 2-}){sup n} where n = 0.5 and 1 for Cd(CN){sub 4}{sup 2-}more » and Ni(CN){sub 4}{sup 2-}, respectively. The rates decreased with increasing pH and were mostly related to a decrease in concentration of the reactive protonated Fe(VI) species, HFeO{sub 4}{sup -}. The stoichiometries with Fe(VI) were determined to be: 4HFeO{sub 4}{sup -} + M(CN){sub 4}{sup 2-} + 6H{sub 2}O {yields} 4Fe(OH){sub 3} + M{sup 2+} + 4NCO{sup -} + O{sub 2} + 4OH{sup -}. Mechanisms are proposed that agree with the observed reaction rate-laws and stoichiometries of the oxidation of weak-acid dissociable cyanides by Fe(VI). Results indicate that Fe(VI) is effective in removing cyanide in coke oven plant effluent, where organics are also present. 27 refs., 3 figs., 2 tabs.« less

  6. 21 CFR 876.4730 - Manual gastroenterology-urology surgical instrument and accessories.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... forceps cover, biopsy tray without biopsy instruments, line clamp, nonpowered rectal probe, nonelectrical..., gastro-urology probe and director, nonself-retaining retractor, laparotomy rings, nonelectrical snare...

  7. 21 CFR 876.4730 - Manual gastroenterology-urology surgical instrument and accessories.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... forceps cover, biopsy tray without biopsy instruments, line clamp, nonpowered rectal probe, nonelectrical..., gastro-urology probe and director, nonself-retaining retractor, laparotomy rings, nonelectrical snare...

  8. 21 CFR 876.4730 - Manual gastroenterology-urology surgical instrument and accessories.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... forceps cover, biopsy tray without biopsy instruments, line clamp, nonpowered rectal probe, nonelectrical..., gastro-urology probe and director, nonself-retaining retractor, laparotomy rings, nonelectrical snare...

  9. 21 CFR 876.4730 - Manual gastroenterology-urology surgical instrument and accessories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... forceps cover, biopsy tray without biopsy instruments, line clamp, nonpowered rectal probe, nonelectrical..., gastro-urology probe and director, nonself-retaining retractor, laparotomy rings, nonelectrical snare...

  10. 21 CFR 876.4730 - Manual gastroenterology-urology surgical instrument and accessories.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... forceps cover, biopsy tray without biopsy instruments, line clamp, nonpowered rectal probe, nonelectrical..., gastro-urology probe and director, nonself-retaining retractor, laparotomy rings, nonelectrical snare...

  11. Development of an Educational Game to Set Up Surgical Instruments on the Mayo Stand or Back Table: Applied Research in Production Technology

    PubMed Central

    2017-01-01

    Background Existing research suggests that digital games can be used effectively for educational purposes at any level of training. Perioperative nursing educators can use games to complement curricula, in guidance and staff development programs, to foster team collaboration, and to give support to critical thinking in nursing practice because it is a complex environment. Objective To describe the process of developing an educational game to set up surgical instruments on the Mayo stand or back table as a resource to assist the instructor in surgical instrumentation training for students and nursing health professionals in continued education. Methods The study was characterized by applied research in production technology. It included the phases of analysis and design, development, and evaluation. The objectives of the educational game were developed through Bloom’s taxonomy. Parallel to the physical development of the educational game, a proposed model for the use of digital elements in educational game activities was applied to develop the game content. Results The development of the game called “Playing with Tweezers” was carried out in 3 phases and was evaluated by 15 participants, comprising students and professional experts in various areas of knowledge such as nursing, information technology, and education. An environment was created with an initial screen, menu buttons containing the rules of the game, and virtual tour modes for learning and assessment. Conclusions The “digital” nursing student needs engagement, stimulation, reality, and entertainment, not just readings. “Playing with Tweezers” is an example of educational gaming as an innovative teaching strategy in nursing that encourages the strategy of involving the use of educational games to support theoretical or practical classroom teaching. Thus, the teacher does not work with only 1 type of teaching methodology, but with a combination of different methodologies. In addition, we

  12. Development of an Educational Game to Set Up Surgical Instruments on the Mayo Stand or Back Table: Applied Research in Production Technology.

    PubMed

    Paim, Crislaine Pires Padilha; Goldmeier, Silvia

    2017-01-10

    Existing research suggests that digital games can be used effectively for educational purposes at any level of training. Perioperative nursing educators can use games to complement curricula, in guidance and staff development programs, to foster team collaboration, and to give support to critical thinking in nursing practice because it is a complex environment. To describe the process of developing an educational game to set up surgical instruments on the Mayo stand or back table as a resource to assist the instructor in surgical instrumentation training for students and nursing health professionals in continued education. The study was characterized by applied research in production technology. It included the phases of analysis and design, development, and evaluation. The objectives of the educational game were developed through Bloom's taxonomy. Parallel to the physical development of the educational game, a proposed model for the use of digital elements in educational game activities was applied to develop the game content. The development of the game called "Playing with Tweezers" was carried out in 3 phases and was evaluated by 15 participants, comprising students and professional experts in various areas of knowledge such as nursing, information technology, and education. An environment was created with an initial screen, menu buttons containing the rules of the game, and virtual tour modes for learning and assessment. The "digital" nursing student needs engagement, stimulation, reality, and entertainment, not just readings. "Playing with Tweezers" is an example of educational gaming as an innovative teaching strategy in nursing that encourages the strategy of involving the use of educational games to support theoretical or practical classroom teaching. Thus, the teacher does not work with only 1 type of teaching methodology, but with a combination of different methodologies. In addition, we cannot forget that skill training in an educational game does not

  13. Inhibition of nitrate reduction by chromium (VI) in anaerobic soil microcosms

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kourtev, P. S.; Nakatsu, C. H.; Konopka, Allan

    2009-10-01

    Chromium (VI) is often found as a co-contaminant at sites polluted with organic compounds. We used microcosms amended with glucose or protein, nitrate and increasing concentrations of chromium to study nitrate reduction in Cr(VI) polluted soils. Organic carbon stimulated bacterial activity, but the addition of Cr(VI) caused a lag and then slower rates 5 of CO2 accumulation. Nitrate reduction only occurred after Cr(VI) had been reduced. Bacterial activity was again inhibited when Cr(VI) was added a second time; thus not all Cr-sensitive bacteria were removed in the first phase. Glucose and protein selected for relatively similar bacterial communities, as assayedmore » by PCR-DGGE of the 16S rRNA gene; this selection was modified by the addition of 10 Cr(VI). Cr-resistant bacteria isolated from microcosms were closely related to members of Bacillus, Enterococcus and Propionibacterium sp. Our results indicate that carbon utilization and nitrate reduction in these soils in the presence of Cr(VI) are contingent upon the reduction of the added heavy metal by a limited subset of the bacterial community. The amount of Cr(VI) required to inhibit nitrate reduction was 10-fold less than for aerobic catabolism of the same 15 substrate. We hypothesize that the resistance level of a microbial process is directly related to the diversity of microbes capable of conducting it.« less

  14. Instrumentation Failure after Partial Corpectomy with Instrumentation of a Metastatic Spine

    PubMed Central

    Park, Sung Bae; Kim, Ki Jeong; Han, Sanghyun; Oh, Sohee; Kim, Chi Heon; Chung, Chun Kee

    2018-01-01

    Objective To identify the perioperative factors associated with instrument failure in patients undergoing a partial corpectomy with instrumentation (PCI) for spinal metastasis. Methods We assessed the one hundred twenty-four patients with who underwent PCI for a metastatic spine from 1987 to 2011. Outcome measure was the risk factor related to implantation failure. The preoperative factors analyzed were age, sex, ambulation, American Spinal Injury Association grade, bone mineral density, use of steroid, primary tumor site, number of vertebrae with metastasis, extra-bone metastasis, preoperative adjuvant chemotherapy, and preoperative spinal radiotherapy. The intraoperative factors were the number of fixed vertebrae, fixation in osteolytic vertebrae, bone grafting, and type of surgical approach. The postoperative factors included postoperative adjuvant chemotherapy and spinal radiotherapy. This study was supported by the National Research Foundation grant funded by government. There were no study-specific biases related to conflicts of interest. Results There were 15 instrumentation failures (15/124, 12.1%). Preoperative ambulatory status and primary tumor site were not significantly related to the development of implant failure. There were no significant associations between insertion of a bone graft into the partial corpectomy site and instrumentation failure. The preoperative and operative factors analyzed were not significantly related to instrumentation failure. In univariable and multivariable analyses, postoperative spinal radiotherapy was the only significant variable related to instrumentation failure (p=0.049 and 0.050, respectively). Conclusion When performing PCI in patients with spinal metastasis followed by postoperative spinal radiotherapy, the surgeon may consider the possibility of instrumentation failure and find other strategies for augmentation than the use of a bone graft for fusion. PMID:29631384

  15. Effect of phosphate on U(VI) sorption to montmorillonite: Ternary complexation and precipitation barriers

    NASA Astrophysics Data System (ADS)

    Troyer, Lyndsay D.; Maillot, Fabien; Wang, Zheming; Wang, Zimeng; Mehta, Vrajesh S.; Giammar, Daniel E.; Catalano, Jeffrey G.

    2016-02-01

    Phosphate addition is a potential treatment method to lower the solubility of U(VI) in soil and groundwater systems by causing U(VI) phosphate precipitation as well as enhancing adsorption. Previous work has shown that iron oxide surfaces may facilitate the nucleation of U(VI) phosphate minerals and, that under weakly acidic conditions, phosphate also enhances U(VI) adsorption to such phases. Like iron oxides, clays are important reactive phases in the subsurface but little is known about the interaction of U(VI) and phosphate with these minerals. The effect of aqueous phosphate on U(VI) binding to Wyoming montmorillonite (SWy-2) in air-equilibrated systems was investigated. Equilibrium U(VI) uptake to montmorillonite was determined at pH 4, 6 and 8 at discrete initial phosphate concentrations between 0 and 100 μM. The observed behavior of U(VI) indicates a transition from adsorption to precipitation with increasing total uranium and phosphate concentrations at all pH values. At the highest phosphate concentration examined at each pH value, a barrier to U(VI) phosphate nucleation is observed. At lower concentrations, phosphate has no effect on macroscopic U(VI) adsorption. To assess the mechanisms of U(VI)-phosphate interactions on smectite surfaces, U(VI) speciation was investigated under selected conditions using laser-induced fluorescence spectroscopy (LIFS) and extended X-ray absorption fine-structure (EXAFS) spectroscopy. Samples above the precipitation threshold display EXAFS and LIFS spectral signatures consistent with the autunite family of U(VI) phosphate minerals. However, at lower U(VI) concentrations, changes in LIFS spectra upon phosphate addition suggest that U(VI)-phosphate ternary surface complexes form on the montmorillonite surface at pH 4 and 6 despite the lack of a macroscopic effect on adsorption. The speciation of solid-associated U(VI) below the precipitation threshold at pH 8 is dominated by U(VI)-carbonate surface complexes. This work

  16. Effect of Phosphate on U(VI) Sorption to Montmorillonite: Ternary Complexation and Precipitation Barriers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Troyer, Lyndsay D.; Maillot, Fabien; Wang, Zheming

    Phosphate addition is a potential treatment method to lower the solubility of U(VI) in soil and groundwater systems by causing U(VI) phosphate precipitation as well as enhancing adsorption. Previous work has shown that iron oxide surfaces may facilitate the nucleation of U(VI) phosphate minerals and, that under weakly acidic conditions, phosphate also enhances U(VI) adsorption to such phases. Like iron oxides, clays are important reactive phases in the subsurface but little is known about the interaction of U(VI) and phosphate with these minerals. The effect of aqueous phosphate on U(VI) binding to Wyoming montmorillonite (SWy-2) in air-equilibrated systems was investigated.more » Equilibrium U(VI) uptake to montmorillonite was determined at pH 4, 6 and 8 at discrete initial phosphate concentrations between 0 and 100 μM. The observed behavior of U(VI) indicates a transition from adsorption to precipitation with increasing total uranium and phosphate concentrations at all pH values. At the highest phosphate concentration examined at each pH value, a barrier to U(VI) phosphate nucleation is observed. At lower concentrations, phosphate has no effect on macroscopic U(VI) adsorption. To assess the mechanisms of U(VI)-phosphate interactions on smectite surfaces, U(VI) speciation was investigated under selected conditions using laser-induced fluorescence spectroscopy (LIFS) and extended X-ray absorption fine-structure (EXAFS) spectroscopy. Samples above the precipitation threshold display EXAFS and LIFS spectral signatures consistent with the autunite family of U(VI) phosphate minerals. However, at lower U(VI) concentrations, changes in LIFS spectra upon phosphate addition suggest that U(VI)-phosphate ternary surface complexes form on the montmorillonite surface at pH 4 and 6 despite the lack of a macroscopic effect on adsorption. The speciation of solid-associated U(VI) below the precipitation threshold at pH 8 is dominated by U(VI)-carbonate surface complexes. This

  17. The MK VI - A second generation attitude control system

    NASA Astrophysics Data System (ADS)

    Meredith, P. J.

    1986-10-01

    The MK VI, a new multipurpose attitude control system for the exoatmospheric attitude control of sounding rocket payloads, is described. The system employs reprogrammable microcomputer memory for storage of basic control logic and for specific mission event control data. The paper includes descriptions of MK VI specifications and configuration; sensor characteristics; the electronic, analog, and digital sections; the pneumatic system; ground equipment; the system operation; and software. A review of the MK VI performance for the Comet Halley flight is presented. Block diagrams are included.

  18. Evaluation of Ophthalmic Surgical Instrument Sterility Using Short-Cycle Sterilization for Sequential Same-Day Use.

    PubMed

    Chang, David F; Hurley, Nikki; Mamalis, Nick; Whitman, Jeffrey

    2018-03-27

    The common practice of short-cycle sterilization for ophthalmic surgical instrumentation has come under increased regulatory scrutiny. This study was undertaken to evaluate the efficacy of short-cycle sterilization processing for consecutive same-day cataract procedures. Testing of specific sterilization processing methods by an independent medical device validation testing laboratory. Phaco handpieces from 3 separate manufacturers were tested along with appropriate biologic indicators and controls using 2 common steam sterilizers. A STATIM 2000 sterilizer (SciCan, Canonsburg, PA) with the STATIM metal cassette, and an AMSCO Century V116 pre-vacuum sterilizer (STERIS, Mentor, OH) using a Case Medical SteriTite container (Case Medical, South Hackensack, NJ) rigid container were tested using phaco tips and handpieces from 3 different manufacturers. Biological indicators were inoculated with highly resistant Geobacillus stearothermophilus, and each sterility verification test was performed in triplicate. Both wrapped and contained loads were tested with full dry cycles and a 7-day storage time to simulate prolonged storage. In adherence with the manufacturers' instructions for use (IFU), short cycles (3.0-3.5-minute exposure times) for unwrapped and contained loads were also tested after only 1 minute of dry time to simulate use on a consecutive case. Additional studies were performed to demonstrate whether any moisture present in the load containing phaco handpieces postprocessing was sterile and would affect the sterility of the contents after a 3-minute transit/storage time. This approximated the upper limit of time needed to transfer a containment device to the operating room. Presence or absence of microbial growth from cultured test samples. All inoculated test samples from both sterilizers were negative for growth of the target organism whether the full dry phase was interrupted or not. Pipetted postprocessing moisture samples and swabs of the handpieces were

  19. Current Limitations of Surgical Robotics in Reconstructive Plastic Microsurgery

    PubMed Central

    Tan, Youri P. A.; Liverneaux, Philippe; Wong, Jason K. F.

    2018-01-01

    Surgical robots have the potential to provide surgeons with increased capabilities, such as removing physiologic tremor, scaling motion and increasing manual dexterity. Several surgical specialties have subsequently integrated robotic surgery into common clinical practice. Plastic and reconstructive microsurgical procedures have not yet  benefitted significantly from technical developments observed over the last two decades. Several studies have successfully demonstrated the feasibility of utilising surgical robots in plastic surgery procedures, yet limited work has been done to identify and analyse current barriers that have prevented wide-scale adaptation of surgical robots for microsurgery. Therefore, a systematic review using PubMed, MEDLINE, Embase and Web of Science databases was performed, in order to evaluate current state of surgical robotics within the field of reconstructive microsurgery and their limitations. Despite the theoretical potential of surgical robots, current commercially available robotic systems are suboptimal for plastic or reconstructive microsurgery. Absence of bespoke microsurgical instruments, increases in operating time, and high costs associated with robotic-assisted provide a barrier to using such systems effectively for reconstructive microsurgery. Consequently, surgical robots provide currently little overall advantage over conventional microsurgery. Nevertheless, if current barriers can be addressed and systems are specifically designed for microsurgery, surgical robots may have the potential of meaningful impact on clinical outcomes within  this surgical subspeciality. PMID:29740585

  20. Kandinsky's "Composition VI": Heideggerian Poetry in Noah's Ark

    ERIC Educational Resources Information Center

    Hall, Joshua M.

    2012-01-01

    The author will begin his investigation of Wassily Kandinsky's painting "Composition VI" with Kandinsky's own commentary on the painting. He will then turn to the analysis of Kandinsky and the "Compositions" in John Sallis's book "Shades." Using this analysis as his point of departure, the author will consider how "Composition VI" resonates with…

  1. A novel design for steerable instruments based on laser-cut nitinol.

    PubMed

    Dewaele, Frank; Kalmar, Alain F; De Ryck, Frederic; Lumen, Nicolaas; Williams, Leonie; Baert, Edward; Vereecke, Hugo; Kalala Okito, Jean Pierre; Mabilde, Cyriel; Blanckaert, Bart; Keereman, Vincent; Leybaert, Luc; Van Nieuwenhove, Yves; Caemaert, Jacques; Van Roost, Dirk

    2014-06-01

    Omnidirectional articulated instruments enhance dexterity. In neurosurgery, for example, the simultaneous use of 2 instruments through the same endoscopic shaft remains a difficult feat. It is, however, very challenging to manufacture steerable instruments of the requisite small diameter. We present a new technique to produce such instruments by means of laser cutting. Only 3 coaxial tubes are used. The middle tube has a cutting pattern that allows the steering forces to be transmitted from the proximal to the distal end. In this way the steering part is concealed in the wall of the tube. Large diameter articulated instruments such as for laparoscopy might benefit from the excellent tip stability provided by the same economical technology. Coaxial nitinol tubes are laser-cut with a Rofin Stent Cutter in a specific pattern. The 3 tubes are assembled by sliding them over one another, forming a single composite tube. In a surgical simulator, the neurosurgical microinstruments and laparoscopic needle drivers were evaluated on surgical convenience. Simultaneous use of 2 neurosurgical instruments (1.5 mm diameter) through the same endoscopic shaft proved to be very intuitive. The tip of the steerable laparoscopic instruments (10 mm diameter) could resist a lateral force of more than 20 N. The angle of motion for either instrument was at least 70° in any direction. A new design for steerable endoscopic instruments is presented. It allows the construction in a range from microinstruments to 10-mm laparoscopic devices with excellent tip stability. © The Author(s) 2013.

  2. Quantifying Cr(VI) Production and Export from Serpentine Soil of the California Coast Range.

    PubMed

    McClain, Cynthia N; Fendorf, Scott; Webb, Samuel M; Maher, Kate

    2017-01-03

    Hexavalent chromium (Cr(VI)) is generated in serpentine soils and exported to surface and groundwaters at levels above health-based drinking water standards. Although Cr(VI) concentrations are elevated in serpentine soil pore water, few studies have reported field evidence documenting Cr(VI) production rates and fluxes that govern Cr(VI) transport from soil to water sources. We report Cr speciation (i) in four serpentine soil depth profiles derived from the California Coast Range serpentinite belt and (ii) in local surface waters. Within soils, we detected Cr(VI) in the same horizons where Cr(III)-minerals are colocated with biogenic Mn(III/IV)-oxides, suggesting Cr(VI) generation through oxidation by Mn-oxides. Water-extractable Cr(VI) concentrations increase with depth constituting a 7.8 to 12 kg/km 2 reservoir of Cr(VI) in soil. Here, Cr(VI) is produced at a rate of 0.3 to 4.8 kg Cr(VI)/km 2 /yr and subsequently flushed from soil during water infiltration, exporting 0.01 to 3.9 kg Cr(VI)/km 2 /yr at concentrations ranging from 25 to 172 μg/L. Although soil-derived Cr(VI) is leached from soil at concentrations exceeding 10 μg/L, due to reduction and dilution during transport to streams, Cr(VI) levels measured in local surface waters largely remain below California's drinking water limit.

  3. Removal of chromium (VI) from aqueous solution using walnut hull.

    PubMed

    Wang, Xue Song; Li, Zhi Zhong; Tao, Sheng Rong

    2009-02-01

    In this study, removal of chromium (VI) from aqueous solution by walnut hull (a local low-cost adsorbent) was studied. The extent of adsorption was investigated as a function of solution pH, contact time, adsorbent and adsorbate concentration, reaction temperature and supporting electrolyte (sodium chloride). The Cr (VI) removal was pH-dependent, reaching a maximum (97.3%) at pH 1.0. The kinetic experimental data were fitted to the first-order, modified Freundlich, intraparticle diffusion and Elovich models and the corresponding parameters were obtained. A 102.78 kJ/mol Ea (activation energy) for the reaction of chromium (VI) adsorption onto walnut indicated that the rate-limiting step in this case might be a chemically controlled process. Both the Langmuir and Freundlich isotherms were suitable for describing the biosorption of chromium (VI) onto walnut hull. The uptake of chromium (VI) per weight of adsorbent increased with increasing initial chromium (VI) concentration up to 240-480 mg/L, and decreased sharply with increasing adsorbent concentration ranging from 1.0 to 5.0 g/L. An increase in sodium chloride (as supporting electrolyte) concentration was found to induce a negative effect while an increase in temperature was found to give rise to a positive effect on the chromium (VI) adsorption process. Compared to the various other adsorbents reported in the literature, the walnut hull in this study shows very good promise for practical applicability.

  4. Kinetic evaluation of chromium(VI) sorption by water lettuce (Pistia).

    PubMed

    Chakraborty, Rupa; Karmakar, Sukalpa; Mukherjee, Somnath; Kumar, Sunil

    2014-01-01

    An investigation was performed to evaluate the uptake capacity of Pistia in living condition for adsorptive removal of chromium(VI) from spiked solution for examining a remedial measure for disposal of chrome-laden wastewater in an urban wetland system. Kinetics results show about 78% removal was achieved for 3 mg/L initial concentration of Cr(VI). Experimental data showed that the root portion absorbed more Cr(VI) (28.54 μg/g) compared to accumulation in leaf (5.73 μg/g). It was also noted that the plant could effectively remove Cr(VI) from the solution with minor damage up to an initial Cr(VI) concentration of 3 mg/L, for which the adsorption isotherm studies were conducted. The maximum uptake capacity of the plant was recorded as 0.05 mg/g of Cr(VI) at the equilibrium level after a contact period of 7 days for an initial concentration of 8 mg /L, although severe physiological damage occurred. The experimental results were plotted in Langmuir and Freundlich isotherm models and both were found to be well fitted (r(2) = 0.979 and r(2) = 0.974 respectively). The high value of n (2.16) reveals a strong bond between the plant root and dissolved Cr(VI), which favours the adsorption process. The order of the reaction was also examined on the basis of uptake capacity and it was found that the second order model fitted best.

  5. 75 FR 80818 - Funding Availability for Title VI Grant Applications; Extension

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-23

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Administration on Aging Funding Availability for Title VI... Administration on Aging is extending the date for which the Title VI grants applications for the grant period... on March 31, 2011. Funding Opportunity Title/Program Name: Older Americans Act (OAA), Title VI, Part...

  6. Malfunction and failure of robotic systems during general surgical procedures.

    PubMed

    Agcaoglu, Orhan; Aliyev, Shamil; Taskin, Halit Eren; Chalikonda, Sricharan; Walsh, Matthew; Costedio, Meagan M; Kroh, Matthew; Rogula, Tomasz; Chand, Bipan; Gorgun, Emre; Siperstein, Allan; Berber, Eren

    2012-12-01

    There has been recent interest in using robots for general surgical procedures. This shift in technique raises the issue of patient safety with automated instrumentation. Although the safety of robotics has been established for urologic procedures, there are scant data on its use in general surgical procedures. The aim of this study is to analyze the incidence of robotic malfunction and its consequences for general surgical procedures. All robotic general surgical procedures performed at a tertiary center between 2008 and 2011 were reviewed from institutional review board (IRB)-approved prospective databases. A total of 223 cases were done robotically, including 102 endocrine, 83 hepatopancreaticobiliary, 17 upper gastrointestinal, and 21 lower gastrointestinal colorectal procedures. There were 10 cases of robotic malfunction (4.5%). These failures were related to robotic instruments (n = 4), optical system (n = 3), robotic arms (n = 2), and robotic console (n = 1). None of these failures led to adverse patient consequences or conversion to open. Six (2.7%) cases were converted to open due to bleeding (n = 3), difficult dissection plane (n = 1), invasion of tumor to surrounding structures (n = 1), and intolerance of pneumoperitoneum due to CO(2) retention (n = 1). There was no mortality, and morbidity was 1% (n = 2). To our knowledge, this is the largest North American report to date on robotic general surgical procedures. Our results show that robotic malfunction occurs in a minority of cases, with no adverse consequences. We believe that awareness of these failures and knowing how to troubleshoot are important to maintain the efficiency of these procedures.

  7. GWM-VI: groundwater management with parallel processing for multiple MODFLOW versions

    USGS Publications Warehouse

    Banta, Edward R.; Ahlfeld, David P.

    2013-01-01

    Groundwater Management–Version Independent (GWM–VI) is a new version of the Groundwater Management Process of MODFLOW. The Groundwater Management Process couples groundwater-flow simulation with a capability to optimize stresses on the simulated aquifer based on an objective function and constraints imposed on stresses and aquifer state. GWM–VI extends prior versions of Groundwater Management in two significant ways—(1) it can be used with any version of MODFLOW that meets certain requirements on input and output, and (2) it is structured to allow parallel processing of the repeated runs of the MODFLOW model that are required to solve the optimization problem. GWM–VI uses the same input structure for files that describe the management problem as that used by prior versions of Groundwater Management. GWM–VI requires only minor changes to the input files used by the MODFLOW model. GWM–VI uses the Joint Universal Parameter IdenTification and Evaluation of Reliability Application Programming Interface (JUPITER-API) to implement both version independence and parallel processing. GWM–VI communicates with the MODFLOW model by manipulating certain input files and interpreting results from the MODFLOW listing file and binary output files. Nearly all capabilities of prior versions of Groundwater Management are available in GWM–VI. GWM–VI has been tested with MODFLOW-2005, MODFLOW-NWT (a Newton formulation for MODFLOW-2005), MF2005-FMP2 (the Farm Process for MODFLOW-2005), SEAWAT, and CFP (Conduit Flow Process for MODFLOW-2005). This report provides sample problems that demonstrate a range of applications of GWM–VI and the directory structure and input information required to use the parallel-processing capability.

  8. Integrated Cr(VI) removal using constructed wetlands and composting.

    PubMed

    Sultana, Mar-Yam; Chowdhury, Abu Khayer Md Muktadirul Bari; Michailides, Michail K; Akratos, Christos S; Tekerlekopoulou, Athanasia G; Vayenas, Dimitrios V

    2015-01-08

    The present work was conducted to study integrated chromium removal from aqueous solutions in horizontal subsurface (HSF) constructed wetlands. Two pilot-scale HSF constructed wetlands (CWs) units were built and operated. One unit was planted with common reeds (Phragmites australis) and one was kept unplanted. Influent concentrations of Cr(VI) ranged from 0.5 to 10mg/L. The effect of temperature and hydraulic residence time (8-0.5 days) on Cr(VI) removal were studied. Temperature was proved to affect Cr(VI) removal in both units. In the planted unit maximum Cr(VI) removal efficiencies of 100% were recorded at HRT's of 1 day with Cr(VI) concentrations of 5, 2.5 and 1mg/L, while a significantly lower removal rate was recorded in the unplanted unit. Harvested reed biomass from the CWs was co-composted with olive mill wastes. The final product had excellent physicochemical characteristics (C/N: 14.1-14.7, germination index (GI): 145-157%, Cr: 8-10mg/kg dry mass), fulfills EU requirements and can be used as a fertilizer in organic farming. Copyright © 2014 Elsevier B.V. All rights reserved.

  9. Augmented reality in laparoscopic surgical oncology.

    PubMed

    Nicolau, Stéphane; Soler, Luc; Mutter, Didier; Marescaux, Jacques

    2011-09-01

    Minimally invasive surgery represents one of the main evolutions of surgical techniques aimed at providing a greater benefit to the patient. However, minimally invasive surgery increases the operative difficulty since the depth perception is usually dramatically reduced, the field of view is limited and the sense of touch is transmitted by an instrument. However, these drawbacks can currently be reduced by computer technology guiding the surgical gesture. Indeed, from a patient's medical image (US, CT or MRI), Augmented Reality (AR) can increase the surgeon's intra-operative vision by providing a virtual transparency of the patient. AR is based on two main processes: the 3D visualization of the anatomical or pathological structures appearing in the medical image, and the registration of this visualization on the real patient. 3D visualization can be performed directly from the medical image without the need for a pre-processing step thanks to volume rendering. But better results are obtained with surface rendering after organ and pathology delineations and 3D modelling. Registration can be performed interactively or automatically. Several interactive systems have been developed and applied to humans, demonstrating the benefit of AR in surgical oncology. It also shows the current limited interactivity due to soft organ movements and interaction between surgeon instruments and organs. If the current automatic AR systems show the feasibility of such system, it is still relying on specific and expensive equipment which is not available in clinical routine. Moreover, they are not robust enough due to the high complexity of developing a real-time registration taking organ deformation and human movement into account. However, the latest results of automatic AR systems are extremely encouraging and show that it will become a standard requirement for future computer-assisted surgical oncology. In this article, we will explain the concept of AR and its principles. Then, we

  10. A survey with Copernicus of interstellar O VI absorption

    NASA Technical Reports Server (NTRS)

    Jenkins, E. B.; Meloy, D. A.

    1974-01-01

    The presence of broad, shallow absorptions caused by O VI ions were revealed from UV spectra observations recorded by the Copernicus satellite for thirty-two stars. A table lists survey data on the stars observed for which values of the O VI column densities or their upper limits are extracted. Interstellar rather than circumstellar origin is evident from observation of the lack of correspondence between radical velocities of the stars and those of the O VI profiles. The presence of a low-density high-temperature phase of interstellar gas produced by supernova explosions is suggested.

  11. Experimental Monitoring of Cr(VI) Bio-reduction Using Electrochemical Geophysics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Birsen Canan; Gary R. Olhoeft; William A. Smith

    2007-09-01

    Many Department of Energy (DOE) sites are contaminated with highly carcinogenic hexavalent chromium (Cr(VI)). In this research, we explore the feasibility of applying complex resistivity to the detection and monitoring of microbially-induced reduction of hexavalent chromium (Cr(VI)) to a less toxic form (Cr(III)). We hope to measure the change in ionic concentration that occurs during this reduction reaction. This form of reduction promises to be an attractive alternative to more expensive remedial treatment methods. The specific goal of this research is to define the minimum and maximum concentration of the chemical and biological compounds in contaminated samples for which themore » Cr(VI) - Cr(III) reduction processes could be detected via complex resistivity. There are three sets of experiments, each comprised of three sample columns. The first experiment compares three concentrations of Cr(VI) at the same bacterial cell concentration. The second experiment establishes background samples with, and without, Cr(VI) and bacterial cells. The third experiment examines the influence of three different bacterial cell counts on the same concentration of Cr(VI). A polarization relaxation mechanism was observed between 10 and 50 Hz. The polarization mechanism, unfortunately, was not unique to bio-chemically active samples. Spectral analysis of complex resistivity data, however, showed that the frequency where the phase minimum occurred was not constant for bio-chemically active samples throughout the experiment. A significant shifts in phase minima occurred between 10 to 20 Hz from the initiation to completion of Cr(VI) reduction. This phenomena was quantified using the Cole-Cole model and the Marquardt-Levenberg nonlinear least square minimization method. The data suggests that the relaxation time and the time constant of this relaxation are the Cole-Cole parameters most sensitive to changes in biologically-induced reduction of Cr(VI).« less

  12. Postoperative K-line conversion from negative to positive is independently associated with a better surgical outcome after posterior decompression with instrumented fusion for K-line negative cervical ossification of the posterior ligament.

    PubMed

    Koda, Masao; Furuya, Takeo; Saito, Junya; Ijima, Yasushi; Kitamura, Mitsuhiro; Ohtori, Seiji; Orita, Sumihisa; Inage, Kazuhide; Abe, Tetsuya; Noguchi, Hiroshi; Funayama, Toru; Kumagai, Hiroshi; Miura, Kosei; Nagashima, Katsuya; Yamazaki, Masashi

    2018-06-01

    Addition of posterior instrumented fusion to laminoplasty (posterior decompression with instrumented fusion: PDF) can improve the surgical outcome of patients with K-line (-) cervical ossification of the longitudinal ligament (OPLL) compared with laminoplasty alone. We sought to elucidate the factors that are significantly associated with a better outcome after PDF for K-line (-) OPLL. The present study included 38 patients who underwent PDF for K-line (-) OPLL and were followed up for at least 1 year after surgery. Clinical outcome was assessed using Japanese Orthopedic Association (JOA) scores for cervical myelopathy and the recovery rate was calculated. Patients who belonged to the upper quartile of all the patients according to rank order of the JOA score recovery rate were considered to have a good outcome. The correlations between good outcome, patient factors and imaging assessments were analyzed statistically. Univariate analyses showed that postoperative conversion of K-line from (-) to (+) (p = 0.004), no increase in the sagittal vertical axis from the center of gravity of the head to C7 (p = 0.07), and a lower grade of preoperative intramedullary T2-signal intensity (p = 0.03) were candidates for the association. Stepwise logistic regression analysis revealed that postoperative K-line conversion from (-) to (+) is an independent factor that is significantly associated with a better surgical outcome (p = 0.04). Postoperative K-line conversion from (-) to (+) is a factor independently associated with a better surgical outcome. These slides can be retrieved under Electronic Supplementary material.

  13. 40 CFR Appendix Vi to Part 1039 - Nonroad Compression-ignition Composite Transient Cycle

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 32 2010-07-01 2010-07-01 false Nonroad Compression-ignition Composite Transient Cycle VI Appendix VI to Part 1039 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... ENGINES Pt. 1039, App. VI Appendix VI to Part 1039—Nonroad Compression-ignition Composite Transient Cycle...

  14. Delineation and Diagnostic Criteria of Oral-Facial-Digital Syndrome Type VI

    PubMed Central

    2012-01-01

    Oral-Facial-Digital Syndrome type VI (OFD VI) represents a rare phenotypic subtype of Joubert syndrome and related disorders (JSRD). In the original report polydactyly, oral findings, intellectual disability, and absence of the cerebellar vermis at post-mortem characterized the syndrome. Subsequently, the molar tooth sign (MTS) has been found in patients with OFD VI, prompting the inclusion of OFD VI in JSRD. We studied the clinical, neurodevelopmental, neuroimaging, and genetic findings in a cohort of 16 patients with OFD VI. We derived the following inclusion criteria from the literature: 1) MTS and one oral finding and polydactyly, or 2) MTS and more than one typical oral finding. The OFD VI neuroimaging pattern was found to be more severe than in other JSRD subgroups and includes severe hypoplasia of the cerebellar vermis, hypoplastic and dysplastic cerebellar hemispheres, marked enlargement of the posterior fossa, increased retrocerebellar collection of cerebrospinal fluid, abnormal brainstem, and frequently supratentorial abnormalities that occasionally include characteristic hypothalamic hamartomas. Additionally, two new JSRD neuroimaging findings (ascending superior cerebellar peduncles and fused thalami) have been identified. Tongue hamartomas, additional frenula, upper lip notch, and mesoaxial polydactyly are specific findings in OFD VI, while cleft lip/palate and other types of polydactyly of hands and feet are not specific. Involvement of other organs may include ocular findings, particularly colobomas. The majority of the patients have absent motor development and profound cognitive impairment. In OFD VI, normal cognitive functions are possible, but exceptional. Sequencing of known JSRD genes in most patients failed to detect pathogenetic mutations, therefore the genetic basis of OFD VI remains unknown. Compared with other JSRD subgroups, the neurological findings and impairment of motor development and cognitive functions in OFD VI are significantly

  15. AGARD Flight Test Instrumentation Series. Volume 7. Strain Gauge Measurements on Aircraft

    DTIC Science & Technology

    1976-04-01

    U.S. DEPARTMENT OF CRY11ERCE Natioal Techaical Infnaitm Soice AD-A026 838 AGARD FLIGHT TEST INSTRUMENTATION SERIES VOLUME 7. STRAIN GUAGE...MEASUREMENTS ON AIRCRAFT ADVISORY GROUP FOR AEROSPACE RESEARCH AND DEVELOPMENT PREPARED FOR.I NORTH ATLANTIC TREATY ORGANIZATION APRIL 1976 • • ,. h VI -i• d...INFORMATION DOCUMENT PROCESSING WORKSHEET ,5.RVICE USCOMM-DC 41420.P7I AGARD-AG-160 Volume 7 NORTH ATLANTIC TREATY ORGANIZATION ADVISORY GROUP FOR AEROSPACE

  16. Optimizing the positional relationships between instruments used in laparoscopic simulation using a simple trigonometric method.

    PubMed

    Lorias Espinoza, Daniel; Ordorica Flores, Ricardo; Minor Martínez, Arturo; Gutiérrez Gnecchi, José Antonio

    2014-06-01

    Various methods for evaluating laparoscopic skill have been reported, but without detailed information on the configuration used they are difficult to reproduce. Here we present a method based on the trigonometric relationships between the instruments used in a laparoscopic training platform in order to provide a tool to aid in the reproducible assessment of surgical laparoscopic technique. The positions of the instruments were represented using triangles. Basic trigonometry was used to objectively establish the distances among the working ports RL, the placement of the optical port h', and the placement of the surgical target OT. The optimal configuration of a training platform depends on the selected working angles, the intracorporeal/extracorporeal lengths of the instrument, and the depth of the surgical target. We demonstrate that some distances, angles, and positions of the instruments are inappropriate for satisfactory laparoscopy. By applying basic trigonometric principles we can determine the ideal placement of the working ports and the optics in a simple, precise, and objective way. In addition, because the method is based on parameters known to be important in both the performance and quantitative quality of laparoscopy, the results are generalizable to different training platforms and types of laparoscopic surgery.

  17. A new look at the WHOQOL as health-related quality of life instrument among visually impaired people using Rasch analysis.

    PubMed

    Gothwal, Vijaya K; Srinivas, Marmamula; Rao, Gullapalli N

    2013-05-01

    To examine the psychometric characteristics of the World Health Organization quality of life instrument-modified Indian version (modified WHOQOL) and its subscales in adults with visual impairment (VI) using Rasch analysis. Cross-sectional data were of people aged ≥40 years with VI (n = 1,333) who responded to the modified WHOQOL in the Andhra Pradesh Eye Disease Study, India. Rasch analysis was used to explore the instrument and its subscales for key indices such as measurement precision by person separation reliability, PSR (i.e., discrimination between strata of participants' health-related QOL [HRQOL], recommended minimum value 0.8), unidimensionality (i.e., measurement of a single construct), and targeting (i.e., matching of item difficulty to participants' HRQOL). Rasch-guided iterative approach including category re-organization to enable threshold ordering and item deletion to overcome multidimensionality resulted in a unidimensional 9-item WHOQOL and a 6-item level of independence (LOI) subscale with adequate PSR (0.81 and 0.82, respectively). Targeting was sub-optimal for both (-1.58 logits for WHOQOL and -2.55 logits for the subscale). Remaining subscales were dysfunctional. The WHOQOL and LOI subscale can be improved and shortened, and the Rasch-revised versions are likely to assess the HROQL of VI patients best because of their brevity, reliability, and unidimensionality.

  18. Quantifying Cr(VI) Production and Export from Serpentine Soil of the California Coast Range

    DOE PAGES

    McClain, Cynthia N.; Fendorf, Scott; Webb, Samuel M.; ...

    2016-11-22

    Here, hexavalent chromium (Cr(VI)) is generated in serpentine soils and exported to surface and groundwaters at levels above health-based drinking water standards. Although Cr(VI) concentrations are elevated in serpentine soil pore water, few studies have reported field evidence documenting Cr(VI) production rates and fluxes that govern Cr(VI) transport from soil to water sources. We report Cr speciation (i) in four serpentine soil depth profiles derived from the California Coast Range serpentinite belt and (ii) in local surface waters. Within soils, we detected Cr(VI) in the same horizons where Cr(III)-minerals are colocated with biogenic Mn(III/IV)-oxides, suggesting Cr(VI) generation through oxidation bymore » Mn-oxides. Water-extractable Cr(VI) concentrations increase with depth constituting a 7.8 to 12 kg/km 2 reservoir of Cr(VI) in soil. Here, Cr(VI) is produced at a rate of 0.3 to 4.8 kg Cr(VI)/km 2/yr and subsequently flushed from soil during water infiltration, exporting 0.01 to 3.9 kg Cr(VI)/km 2/yr at concentrations ranging from 25 to 172 μg/L. Although soil-derived Cr(VI) is leached from soil at concentrations exceeding 10 μg/L, due to reduction and dilution during transport to streams, Cr(VI) levels measured in local surface waters largely remain below California’s drinking water limit.« less

  19. [Treatment of wastewater containing Cr(VI) by LDH synthesizing in situ].

    PubMed

    Chen, Tian-hu; Feng, You-liang; Xu, Hui-fang; Peng, Shu-chuan; Huang, Chuan-hui; Tang, Shu-pei

    2004-03-01

    The objective of this work was to investigate the efficiency and factors impacting of removal Cr(VI) from wastewater by layer double hydroxide synthesizing in situ. Principle of the method may be described as follow: Mg2+ and Al3+ hydrolysis and forms Mg/Al-LDH by adding Mg2+, Al3+ and NaOH into wastewater containing Cr(VI), Cr(VI) anions are selectively intercalated into interlayer of LDH to balance positive structural charge. While Mg2+ and Al3+ co-precipitates and forms LDH, the Cr(VI) in wastewater is removal by settle of LDH synthesizing in situ, which are confirmed by analysis of X-ray diffraction on settle and chemical analysis on aqueous. The results indicate that factors of impacting on efficiency of removal Cr(VI) include in amount of adding Mg2+ and Al3+, Mg/Al ratio, pH and concentration of Cr(VI) in wastewater. The maximal removal efficiency of Cr(VI) can be reached when pH values are between 8.5 and 9, and Mg/Al ratios are between 1:1 and 2:1, meanwhile, Mg and Al added can be taken good use of. This technology has present extraordinary efficiency of wastewater treatment.

  20. Thermodynamic analysis of Cr(VI) extraction using TOPO impregnated membranes.

    PubMed

    Praveen, Prashant; Loh, Kai-Chee

    2016-08-15

    Solid/liquid extraction of Cr(VI) was accomplished using trioctylphosphine oxide impregnated polypropylene hollow fiber membranes. Extraction of 100-500mg/L Cr(VI) by the extractant impregnated membranes (EIM) was characterized by high uptake rate and capacity, and equilibrium was attained within 45min of contact. Extraction equilibrium was pH-dependent (at an optimal pH 2), whereas stripping using 0.2M sodium hydroxide yielded the highest recovery of 98% within 60min. The distribution coefficient was independent of initial Cr(VI) concentration, and the linear distribution equilibrium isotherm could be modeled using Freundlich isotherm. The mass transfer kinetics of Cr(VI) was examined using pseudo-second-order and intraparticle diffusion models and a mass transfer mechanism was deduced. The distribution coefficient increased with temperature, which indicated endothermic nature of the reaction. Enthalpy and entropy change during Cr(VI) extraction were positive and varied in the range of 37-49kJ/mol and 114-155J/mol, respectively. The free energy change was negative, confirming the feasibility and spontaneity of the mass transfer process. Results obtained suggest that EIMs are efficient and sustainable for extraction of Cr(VI) from wastewater. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. Validation of a virtual reality-based robotic surgical skills curriculum.

    PubMed

    Connolly, Michael; Seligman, Johnathan; Kastenmeier, Andrew; Goldblatt, Matthew; Gould, Jon C

    2014-05-01

    The clinical application of robotic-assisted surgery (RAS) is rapidly increasing. The da Vinci Surgical System™ is currently the only commercially available RAS system. The skills necessary to perform robotic surgery are unique from those required for open and laparoscopic surgery. A validated laparoscopic surgical skills curriculum (fundamentals of laparoscopic surgery or FLS™) has transformed the way surgeons acquire laparoscopic skills. There is a need for a similar skills training and assessment tool specific for robotic surgery. Based on previously published data and expert opinion, we developed a robotic skills curriculum. We sought to evaluate this curriculum for evidence of construct validity (ability to discriminate between users of different skill levels). Four experienced surgeons (>20 RAS) and 20 novice surgeons (first-year medical students with no surgical or RAS experience) were evaluated. The curriculum comprised five tasks utilizing the da Vinci™ Skills Simulator (Pick and Place, Camera Targeting 2, Peg Board 2, Matchboard 2, and Suture Sponge 3). After an orientation to the robot and a period of acclimation in the simulator, all subjects completed three consecutive repetitions of each task. Computer-derived performance metrics included time, economy of motion, master work space, instrument collisions, excessive force, distance of instruments out of view, drops, missed targets, and overall scores (a composite of all metrics). Experienced surgeons significantly outperformed novice surgeons in most metrics. Statistically significant differences were detected for each task in regards to mean overall scores and mean time (seconds) to completion. The curriculum we propose is a valid method of assessing and distinguishing robotic surgical skill levels on the da Vinci Si™ Surgical System. Further study is needed to establish proficiency levels and to demonstrate that training on the simulator with the proposed curriculum leads to improved robotic

  2. Analysis of the learning curve for transurethral resection of the prostate. Is there any influence of musical instrument and video game skills on surgical performance?

    PubMed

    Yamaçake, Kleiton Gabriel Ribeiro; Nakano, Elcio Tadashi; Soares, Iva Barbosa; Cordeiro, Paulo; Srougi, Miguel; Antunes, Alberto Azoubel

    2015-09-01

    To evaluate the learning curve for transurethral resection of the prostate (TURP) among urology residents and study the impact of video game and musical instrument playing abilities on its performance. A prospective study was performed from July 2009 to January 2013 with patients submitted to TURP for benign prostatic hyperplasia. Fourteen residents operated on 324 patients. The following parameters were analyzed: age, prostate-specific antigen levels, prostate weight on ultrasound, pre- and postoperative serum sodium and hemoglobin levels, weight of resected tissue, operation time, speed of resection, and incidence of capsular lesions. Gender, handedness, and prior musical instrument and video game playing experience were recorded using survey responses. The mean resection speed in the first 10 procedures was 0.36 g/min and reached a mean of 0.51 g/min after the 20(th) procedure. The incidence of capsular lesions decreased progressively. The operation time decreased progressively for each subgroup regardless of the difference in the weight of tissue resected. Those experienced in playing video games presented superior resection speed (0.45 g/min) when compared with the novice (0.35 g/min) and intermediate (0.38 g/min) groups (p=0.112). Musical instrument playing abilities did not affect the surgical performance. Speed of resection, weight of resected tissue, and percentage of resected tissue improve significantly and the incidence of capsular lesions reduces after the performance of 10 TURP procedures. Experience in playing video games or musical instruments does not have a significant effect on outcomes.

  3. Analysis of the learning curve for transurethral resection of the prostate. Is there any influence of musical instrument and video game skills on surgical performance?

    PubMed Central

    Yamaçake, Kleiton Gabriel Ribeiro; Nakano, Elcio Tadashi; Soares, Iva Barbosa; Cordeiro, Paulo; Srougi, Miguel; Antunes, Alberto Azoubel

    2015-01-01

    Objective To evaluate the learning curve for transurethral resection of the prostate (TURP) among urology residents and study the impact of video game and musical instrument playing abilities on its performance. Material and methods A prospective study was performed from July 2009 to January 2013 with patients submitted to TURP for benign prostatic hyperplasia. Fourteen residents operated on 324 patients. The following parameters were analyzed: age, prostate-specific antigen levels, prostate weight on ultrasound, pre- and postoperative serum sodium and hemoglobin levels, weight of resected tissue, operation time, speed of resection, and incidence of capsular lesions. Gender, handedness, and prior musical instrument and video game playing experience were recorded using survey responses. Results The mean resection speed in the first 10 procedures was 0.36 g/min and reached a mean of 0.51 g/min after the 20th procedure. The incidence of capsular lesions decreased progressively. The operation time decreased progressively for each subgroup regardless of the difference in the weight of tissue resected. Those experienced in playing video games presented superior resection speed (0.45 g/min) when compared with the novice (0.35 g/min) and intermediate (0.38 g/min) groups (p=0.112). Musical instrument playing abilities did not affect the surgical performance. Conclusion Speed of resection, weight of resected tissue, and percentage of resected tissue improve significantly and the incidence of capsular lesions reduces after the performance of 10 TURP procedures. Experience in playing video games or musical instruments does not have a significant effect on outcomes. PMID:26516596

  4. Kinetics of reduction of plutonium(VI) and neptunium(VI) by sulfide in neutral and alkaline solutions

    USGS Publications Warehouse

    Nash, K.L.; Cleveland, J.M.; Sullivan, J.C.; Woods, M.

    1986-01-01

    The rate of reduction of plutonium(VI) and neptunium(VI) by bisulfide ion in neutral and mildly alkaline solutions has been investigated by the stopped-flow technique. The reduction of both of these ions to the pentavalent oxidation state appears to occur in an intramolecular reaction involving an unusual actinide(VI)-hydroxide-bisulfide complex. For plutonium the rate of reduction is 27.4 (??4.1) s-1 at 25??C with ??H* = +33.2 (??1.0) kJ/mol and ??S* = -106 (??4) J/(mol K). The apparent stability constant for the transient complex is 4.66 (??0.94) ?? 103 M-1 at 25??C with associated thermodynamic parameters of ??Hc = +27.7 (??0.4) kJ/mol and ??Sc = +163 (??2) J/(mol K). The corresponding rate and stability constants are determined for the neptunium system at 25??C (k3 = 139 (??30) s-1, Kc. = 1.31 (??0.32) ?? 103 M-1), but equivalent parameters cannot be determined at reduced temperatures. The reaction rate is decreased by bicarbonate ion. At pH > 10.5, a second reaction mechanism, also involving a sulfide complex, is indicated. ?? 1986 American Chemical Society.

  5. A highly selective chemiluminescent probe for the detection of chromium(VI)

    NASA Astrophysics Data System (ADS)

    Jin, Yan; Sun, Yonghua; Li, Chongying; Yang, Chao

    2018-03-01

    In present work, rhodamine B hydrazide and rhodamine 6G hydrazide were synthesized and the chemiluminescence performance has been investigated. Based on the chemiluminescence of rhodamine 6G hydrazide-chromium(VI), a selective and sensitive method for the direct detection of chromium(VI) was developed. The chemiluminescence intensity was linearly related to the concentration of chromium(VI) in the range of 2.60 × 10- 8-8.00 × 10- 6 mol/L with a correlation coefficient of r = 0.998 and a detection limit of 1.4 × 10- 8 mol/L (S/N = 3). The results indicated rhodamine 6G hydrazide was an excellent chemiluminescent probe for chromium(VI) without reduction of chromium(VI) to chromium(III). A possible mechanism of CL emission was also suggested.

  6. Validation of an electrothermal atomization atomic absorption spectrometry method for quantification of total chromium and chromium(VI) in wild mushrooms and underlying soils.

    PubMed

    Figueiredo, Estela; Soares, M Elisa; Baptista, Paula; Castro, Marisa; Bastos, M Lourdes

    2007-08-22

    An ETAAS method was validated to quantify total Cr and Cr(VI) in mushrooms and the underlying soils. The method includes a sample pretreatment for total Cr dissolution using a wet acid digestion procedure and a selective alkaline extraction for Cr(VI). The limits of detection were, expressed in microg/L, 0.15 and 0.17 for total Cr and Cr(VI), respectively. The linearity ranges under the optimized conditions were 0.15-25.0 and 0.17-20.0 microg/L for total Cr and Cr(VI), respectively. The limits of quantification were, expressed in microg/g of dry weight, 0.0163 and 0.0085 for total and hexavalent chromium, respectively. The precision of the instrumental method for total Cr and Cr(VI) was lower than 1.6%, and for the analytical method, it was lower than 10%. The accuracy of the method for Cr(VI) quantification was evaluated by the standard additions method, with the recoveries being higher than 90% for all of the added concentrations. For total Cr, certified reference materials (lichen CRM 482 and soil sample NCS ZC73001) were used. An interference study was also carried out in a mushroom simulated matrix, and it was verified that the deviations of the expected values were lower than 4.0% for both total Cr and Cr(VI). The validated method was applied to the evaluation of total Cr and Cr(VI) in 34 wild mushrooms and 34 respective underlying soil samples collected in two different regions of Portugal (Beira Interior and TrAs-os-Montes), with different locations regarded as noncontaminated or contaminated areas. The species were identified by a mycologist and subdivided into 10 genera and 15 species: Amanita (rubescens, muscaria, and ponderosa), Boletus (regius), Lactarius (deliciosus, vellereus, and piperatus), Suillus (granulatus and luteus), Tricholoma (acerbum), Agaricus (sylvicola), Volvariella (gloiocephala), Lecopaxillus (giganteus), Macrolepiota (procera), and Psilocybe (fascicularis). The mean values found for total Cr were 1.14 and 1.11 microg/g of dry weight

  7. Long-term diffusion of U(VI) in bentonite: Dependence on density

    DOE PAGES

    Joseph, Claudia; Mibus, Jens; Trepte, Paul; ...

    2016-10-12

    As a contribution to the safety assessment of nuclear waste repositories, U(VI) diffusion through the potential buffer material MX-80 bentonite was investigated at three clay dry densities over six years. Synthetic MX-80 model pore water was used as background electrolyte. Speciation calculations showed that Ca 2UO 2(CO 3) 3(aq) was the main U(VI) species. The in- and out-diffusion of U(VI) was investigated separately. U(VI) diffused about 3 mm, 1.5 mm, and 1 mm into the clay plug at ρ = 1.3, 1.6, and 1.9 g/cm 3, respectively. No through-diffusion of the U(VI) tracer was observed. However, leaching of natural uraniummore » contained in the clay occurred and uranium was detected in all receiving reservoirs. As expected, the effective and apparent diffusion coefficients, D e and D a, decreased with increasing dry density. The D a values for the out-diffusion of natural U(VI) were in good agreement with previously determined values. Surprisingly, D a values for the in-diffusion of U(VI) were about two orders of magnitude lower than values obtained in short-term in-diffusion experiments reported in the literature. Some potential reasons for this behavior that were evaluated are changes of the U(VI) speciation within the clay (precipitation, reduction) or changes of the clay porosity and pore connectivity with time. By applying Archie's law and the extended Archie's law, it was estimated that a significantly smaller effective porosity must be present for the long-term in-diffusion of U(VI). Finally, the results suggest that long-term studies of key transport phenomena may reveal additional processes that can directly impact long-term repository safety assessments.« less

  8. Enzyme replacement therapy with galsulfase in 34 children younger than five years of age with MPS VI.

    PubMed

    Horovitz, Dafne D G; Magalhães, Tatiana S P C; Acosta, Angelina; Ribeiro, Erlane M; Giuliani, Liane R; Palhares, Durval B; Kim, Chong A; de Paula, Ana Carolina; Kerstenestzy, Marcelo; Pianovski, Mara A D; Costa, Maria Ione F; Santos, Francisca C; Martins, Ana Maria; Aranda, Carolina S; Correa Neto, Jordão; Holanda, Gervina Brady Moreira; Cardoso, Laércio; da Silva, Carlos A B; Bonatti, Renata C F; Ribeiro, Bethania F R; Rodrigues, Maria do Carmo S; Llerena, Juan C

    2013-05-01

    Mucopolysaccharidosis type VI (MPS VI) is a progressive, chronic and multisystem lysosomal storage disease with a wide disease spectrum. Clinical and biochemical improvements have been reported for MPS VI patients on enzyme replacement therapy (ERT) with rhASB (recombinant human arylsulfatase B; galsulfase, Naglazyme®, BioMarin Pharmaceutical Inc.), making early diagnosis and intervention imperative for optimal patient outcomes. Few studies have included children younger than five years of age. This report describes 34 MPS VI patients that started treatment with galsulfase before five years of age. Data from patients who initiated treatment at <5 years of age were collected from patients' medical records. Baseline and follow-up assessments of common symptoms that led to diagnosis and that were used to evaluate disease progression and treatment efficacy were evaluated. A significant negative correlation was seen with treatment with ERT and urinary GAG levels. Of those with baseline and follow-up growth data, 47% remained on their pre-treatment growth curve or moved to a higher percentile after treatment. Of the 9 patients with baseline and follow-up sleep studies, 5 remained unaffected and 1 patient initially with mild sleep apnea showed improvement. Data regarding cardiac, ophthalmic, central nervous system, hearing, surgical interventions and development are also reported. No patient discontinued treatment due to an adverse event and all that were treatment-emergent resolved. The prescribed dosage of 1mg/kg IV weekly with galsulfase ERT is shown to be safe and effective in slowing and/or improving certain aspects of the disease, although patients should be closely monitored for complications associated with the natural history of the disease, especially cardiac valve involvement and spinal cord compression. A long-term follow-up investigation of this group of children will provide further information on the benefits of early treatment as well as disease

  9. HNO3 modified biochars for uranium (VI) removal from aqueous solution.

    PubMed

    Jin, Jie; Li, Shiwei; Peng, Xianqiang; Liu, Wei; Zhang, Chenlu; Yang, Yan; Han, Lanfang; Du, Ziwen; Sun, Ke; Wang, Xiangke

    2018-05-01

    The HNO 3 treatment was used to chemically modify the biochars produced from wheat straw (WH) and cow manure for U(VI) removal from aqueous solution. Macroscopic experiments proved that the enrichment of U(VI) on the biochars was regulated by surface complexation and electrostatic interactions. FTIR and XPS analyses confirmed that the highly efficient adsorption of U(VI) was due to the carboxyl groups on the biochar surfaces. The reducing agents of the R-CH 2 OH groups facilitated U(VI) adsorption on the untreated biochars. Owing to the higher contents of surface COO groups and more negative surface charge, the modified biochars showed enhanced U(VI) adsorption ability than the untreated ones. The maximum adsorption capacity of U(VI) by the oxidized WH was calculated to be 355.6 mg/g at pH 4.5 and 298 K, which was an improvement of 40 times relative to the untreated WH and was higher than that of most carbon-based adsorbents. Copyright © 2018 Elsevier Ltd. All rights reserved.

  10. Music psychopathology. VI. The course objective instrumental performance characteristics with psychiatric inpatients.

    PubMed

    Steinberg, R; Fani, M; Raith, L

    1992-01-01

    The impairment of musical expression due to mental disease is reversible with growing remission. This finding resulted from follow-up examinations of instrumental playings assessed by means of a polarity profile with 60 psychiatric inpatients and 14 controls. A follow-up comparison of objective performance characteristics as defined by careful analysis of the recordings did not reveal a meaningful variation. This is taken as a strong indication that even in severe psychopathologic alterations, learned motor patterns of music performance are fairly stable. A simple reduction in playing irregularities cannot explain the systematic influence of psychopathology on musical expression.

  11. 21 CFR 882.4545 - Shunt system implantation instrument.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Shunt system implantation instrument. 882.4545 Section 882.4545 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4545 Shunt system...

  12. 21 CFR 882.4545 - Shunt system implantation instrument.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Shunt system implantation instrument. 882.4545 Section 882.4545 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4545 Shunt system...

  13. 21 CFR 882.4190 - Clip forming/cutting instrument.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Clip forming/cutting instrument. 882.4190 Section 882.4190 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4190 Clip forming...

  14. 21 CFR 882.4500 - Cranioplasty material forming instrument.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Cranioplasty material forming instrument. 882.4500 Section 882.4500 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4500 Cranioplasty...

  15. 21 CFR 882.4500 - Cranioplasty material forming instrument.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Cranioplasty material forming instrument. 882.4500 Section 882.4500 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4500 Cranioplasty...

  16. Voice tuning with new instruments for type II thyroplasty in the treatment of adductor spasmodic dysphonia.

    PubMed

    Sanuki, Tetsuji; Yumoto, Eiji; Toya, Yutaka; Kumai, Yoshihiko

    2016-10-01

    Adductor spasmodic dysphonia is a rare voice disorder characterized by strained and strangled voice quality with intermittent phonatory breaks and adductory vocal fold spasms. Type II thyroplasty differs from previous treatments in that this surgery does not involve any surgical intervention into the laryngeal muscle, nerve or vocal folds. Type II thyroplasty intervenes in the thyroid cartilage, which is unrelated to the lesion. This procedure, conducted with the aim of achieving lateralization of the vocal folds, requires utmost surgical caution due to the extreme delicacy of the surgical site, critically sensitive adjustment, and difficult procedures to maintain the incised cartilages at a correct position. During surgery, the correct separation of the incised cartilage edges with voice monitoring is the most important factor determining surgical success and patient satisfaction. We designed new surgical instruments: a thyroid cartilage elevator for undermining the thyroid cartilage, and spacer devices to gauge width while performing voice monitoring. These devices were designed to prevent surgical complications, and to aid in selecting the optimal size of titanium bridges while temporally maintaining a separation during voice monitoring. We designed new surgical instruments, including a thyroid cartilage elevator and spacer devices. Precise surgical procedures and performing voice tuning during surgery with the optimal separation width of the thyroid cartilage are key points for surgical success. We introduce the technique of voice tuning using these surgical tools in order to achieve a better outcome with minimal surgical complications. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  17. Treatment of Alkaline Cr(VI)-Contaminated Leachate with an Alkaliphilic Metal-Reducing Bacterium.

    PubMed

    Watts, Mathew P; Khijniak, Tatiana V; Boothman, Christopher; Lloyd, Jonathan R

    2015-08-15

    Chromium in its toxic Cr(VI) valence state is a common contaminant particularly associated with alkaline environments. A well-publicized case of this occurred in Glasgow, United Kingdom, where poorly controlled disposal of a cementitious industrial by-product, chromite ore processing residue (COPR), has resulted in extensive contamination by Cr(VI)-contaminated alkaline leachates. In the search for viable bioremediation treatments for Cr(VI), a variety of bacteria that are capable of reduction of the toxic and highly soluble Cr(VI) to the relatively nontoxic and less mobile Cr(III) oxidation state, predominantly under circumneutral pH conditions, have been isolated. Recently, however, alkaliphilic bacteria that have the potential to reduce Cr(VI) under alkaline conditions have been identified. This study focuses on the application of a metal-reducing bacterium to the remediation of alkaline Cr(VI)-contaminated leachates from COPR. This bacterium, belonging to the Halomonas genus, was found to exhibit growth concomitant to Cr(VI) reduction under alkaline conditions (pH 10). Bacterial cells were able to rapidly remove high concentrations of aqueous Cr(VI) (2.5 mM) under anaerobic conditions, up to a starting pH of 11. Cr(VI) reduction rates were controlled by pH, with slower removal observed at pH 11, compared to pH 10, while no removal was observed at pH 12. The reduction of aqueous Cr(VI) resulted in the precipitation of Cr(III) biominerals, which were characterized using transmission electron microscopy and energy-dispersive X-ray analysis (TEM-EDX) and X-ray photoelectron spectroscopy (XPS). The effectiveness of this haloalkaliphilic bacterium for Cr(VI) reduction at high pH suggests potential for its use as an in situ treatment of COPR and other alkaline Cr(VI)-contaminated environments. Copyright © 2015, Watts et al.

  18. A study of the kinetics and isotherms for Cr(VI) adsorption in a binary mixture of Cr(VI)-Ni(II) using hierarchical porous carbon obtained from pig bone.

    PubMed

    Li, Chengxian; Huang, Zhe; Huang, Bicheng; Liu, Changfeng; Li, Chengming; Huang, Yaqin

    2014-01-01

    Cr(VI) adsorption in a binary mixture Cr(VI)-Ni(II) using the hierarchical porous carbon prepared from pig bone (HPC) was investigated. The various factors affecting adsorption of Cr(VI) ions from aqueous solutions such as initial concentration, pH, temperature and contact time were analyzed. The results showed excellent efficiency of Cr(VI) adsorption by HPC. The kinetics and isotherms for Cr(VI) adsorption from a binary mixture Cr(VI)-Ni(II) by HPC were studied. The adsorption equilibrium described by the Langmuir isotherm model is better than that described by the Freundlich isotherm model for the binary mixture in this study. The maximum adsorption capacity was reliably found to be as high as 192.68 mg/g in the binary mixture at pH 2. On fitting the experimental data to both pseudo-first- and second-order equations, the regression analysis of the second-order equation gave a better R² value.

  19. Application of a Compact High-Definition Exoscope for Illumination and Magnification in High-Precision Surgical Procedures.

    PubMed

    Krishnan, Kartik G; Schöller, Karsten; Uhl, Eberhard

    2017-01-01

    The basic necessities for surgical procedures are illumination, exposure, and magnification. These have undergone transformation in par with technology. One of the recent developments is the compact magnifying exoscope system. In this report, we describe the application of this system for surgical operations and discuss its advantages and pitfalls. We used the ViTOM exoscope mounted on the mechanical holding arm. The following surgical procedures were conducted: lumbar and cervical spinal canal decompression (n = 5); laminotomy and removal of lumbar migrated disk herniations (n = 4); anterior cervical diskectomy and fusion (n = 1); removal of intraneural schwannomas (n = 2); removal of an acute cerebellar hemorrhage (n = 1); removal of a parafalcine atypical cerebral hematoma caused by a dural arteriovenous fistula (n = 1); and microsutures and anastomoses of a nerve (n = 1), an artery (n = 1), and veins (n = 2). The exoscope offered excellent, magnified, and brilliantly illuminated high-definition images of the surgical field. All surgical operations were successfully completed. The main disadvantage was the adjustment and refocusing using the mechanical holding arm. The time required for the surgical operation under the exoscope was slightly longer than the times required for a similar procedure performed using an operating microscope. The magnifying exoscope is an effective and nonbulky tool for surgical procedures. In visualization around the corners, the exoscope has better potential than a microscope. With technical and technologic modifications, the exoscope might become the next generation in illumination, visualization, exposure, and magnification for high-precision surgical procedures. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. The indirect cost of Patient-Specific Instruments.

    PubMed

    Thienpont, Emmanuel; Paternostre, Frederic; Van Wymeersch, Charles

    2015-09-01

    To calculate the indirect costs of Patient Specific Instruments (PSI) based on an opportunity cost, cost of efforts and a supply chain cost model to compare PSI for value with conventional total knee arthroplasty (TKA). In 81 patients the total (direct+indirect) cost of PSI-assisted TKA was compared with conventional TKA. Surgical times and coronal mechanical alignment were measured to evaluate the effectiveness of the PSI system. Indirect costs (459 euro) make up 40% of the total cost that can run up to 1142 euro for a patient operated with PSI guides. No difference in surgical times or coronal alignment was observed in between both groups. Considering the total cost of PSI no value was found for the use of PSI in primary TKA as measured by surgical times or for obtaining a neutral mechanical axis in the coronal plane.

  1. Multi-crystalline II-VI based multijunction solar cells and modules

    DOEpatents

    Hardin, Brian E.; Connor, Stephen T.; Groves, James R.; Peters, Craig H.

    2015-06-30

    Multi-crystalline group II-VI solar cells and methods for fabrication of same are disclosed herein. A multi-crystalline group II-VI solar cell includes a first photovoltaic sub-cell comprising silicon, a tunnel junction, and a multi-crystalline second photovoltaic sub-cell. A plurality of the multi-crystalline group II-VI solar cells can be interconnected to form low cost, high throughput flat panel, low light concentration, and/or medium light concentration photovoltaic modules or devices.

  2. Uranium(VI) adsorption to ferrihydrite: Application of a surface complexation model

    USGS Publications Warehouse

    Waite, T.D.; Davis, J.A.; Payne, T.E.; Waychunas, G.A.; Xu, N.

    1994-01-01

    A study of U(VI) adsorption by ferrihydrite was conducted over a wide range of U(VI) concentrations, pH, and at two partial pressures of carbon dioxide. A two-site (strong- and weak-affinity sites, FesOH and FewOH, respectively) surface complexation model was able to describe the experimental data well over a wide range of conditions, with only one species formed with each site type: an inner-sphere, mononuclear, bidentate complex of the type (FeO2)UO2. The existence of such a surface species was supported by results of uranium EXAFS spectroscopy performed on two samples with U(VI) adsorption density in the upper range observed in this study (10 and 18% occupancy of total surface sites). Adsorption data in the alkaline pH range suggested the existence of a second surface species, modeled as a ternary surface complex with UO2CO30 binding to a bidentate surface site. Previous surface complexation models for U(VI) adsorption have proposed surface species that are identical to the predominant aqueous species, e.g., multinuclear hydrolysis complexes or several U(VI)-carbonate complexes. The results demonstrate that the speciation of adsorbed U(VI) may be constrained by the coordination environment at the surface, giving rise to surface speciation for U(VI) that is significantly less complex than aqueous speciation.

  3. Implant positioning in TKA: comparison between conventional and patient-specific instrumentation.

    PubMed

    Ferrara, Ferdinando; Cipriani, Antonio; Magarelli, Nicola; Rapisarda, Santi; De Santis, Vincenzo; Burrofato, Aaron; Leone, Antonio; Bonomo, Lorenzo

    2015-04-01

    The number of total knee arthroplasty (TKA) procedures continuously increases, with good to excellent results. In the last few years, new surgical techniques have been developed to improve prosthesis positioning. In this context, patient-specific instrumentation is included. The goal of this study was to compare the perioperative parameters and the spatial positioning of prosthetic components in TKA procedures performed with patient-specific instrumentation vs traditional TKA. In this prospective comparative randomized study, 15 patients underwent TKA with 3-dimensional magnetic resonance imaging (MRI) preoperative planning (patient-specific instrumentation group) and 15 patients underwent traditional TKA (non-patient-specific instrumentation group). All patients underwent postoperative computed tomography (CT) examination. In the patient-specific instrumentation group, preoperative data planning regarding femoral and tibial bone resection was correlated with intraoperative measurements. Surgical time, length of hospitalization, and intraoperative and postoperative bleeding were compared between the 2 groups. Positioning of implants on postoperative CT was assessed for both groups. Data planned with 3-dimensional MRI regarding the depth of bone cuts showed good to excellent correlation with intraoperative measurements. The patient-specific instrumentation group showed better perioperative outcomes and good correlation between the spatial positioning of prosthetic components planned preoperatively and that seen on postoperative CT. Less variability was found in the patient-specific instrumentation group than in the non-patient-specific instrumentation group in spatial orientation of prosthetic components. Preoperative planning with 3-dimensional MRI in TKA has a better perioperative outcome compared with the traditional method. Use of patient-specific instrumentation can also improve the spatial positioning of both prosthetic components. Copyright 2015, SLACK

  4. Capturing children and young people's perspectives to identify the content for a novel vision-related quality of life instrument.

    PubMed

    Rahi, Jugnoo S; Tadić, Valerie; Keeley, Sarah; Lewando-Hundt, Gillian

    2011-05-01

    To describe a child-centered approach to identifying content for a novel self-report questionnaire for assessing vision-related quality of life (QoL) of visually impaired (VI) or blind (BL) children and young people. Questionnaire development. A stratified random patient sample of children and young people who are VI/BL (visual acuity in the better eye Snellen <6/18; logarithm of the minimum angle of resolution <0.51) as the result of any visual disorder, but in the absence of any other significant impairment, aged 10 to 15 years (N=49); and a convenience school-based sample of children and young people who are VI/BL and aged 10 to 17 years (N=29). Individual interviews were conducted with a stratified random sample of 32 children and young people, aged 10 to 15 years, who were VI/BL. The interviews followed a topic guide based on vision-related issues identified from a focus group of affected children and young people, combined with a literature review and consultations with professionals. Collaborative qualitative thematic analysis was undertaken and used to derive draft items of the instrument, using the children's own language wherever possible. Items were reduced, rephrased, and refined through individual consultation, as well as an expert reference group of children and young people who were VI/BL, and supplemented by the research team's consensus. A draft 47-item instrument. A total of 874 potential questionnaire items were initially generated spanning the following domains: social relations, acceptance, and participation; independence and autonomy; psychological and emotional well-being; future-aspirations and fears; functioning-home, school, and leisure; and treatment of eye condition. This was eventually reduced to a 47-item instrument with each item presented as a vignette describing a QoL issue from an "illustrative" child's perspective. Thus, the responding child reports on how much he/she is presently like and how much he/she wishes to be like that

  5. 24 CFR 972.115 - Relationship between required conversions and HOPE VI developments.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... conversions and HOPE VI developments. 972.115 Section 972.115 Housing and Urban Development Regulations... Relationship between required conversions and HOPE VI developments. HUD actions to approve or deny proposed HOPE VI revitalization plans must be consistent with the requirements of this subpart. Developments...

  6. Ferrate(VI) oxidation of polychlorinated diphenyl sulfides: Kinetics, degradation, and oxidized products.

    PubMed

    Chen, Jing; Xu, Xinxin; Zeng, Xiaolan; Feng, Mingbao; Qu, Ruijuan; Wang, Zunyao; Nesnas, Nasri; Sharma, Virender K

    2018-06-13

    This paper presents oxidation of polychlorinated diphenyl sulfides (PCDPSs), dioxin-like compounds, by ferrate(VI) (Fe VI O 4 2- , Fe(VI)). Kinetics of the reactions of Fe(VI) with seventeen PCDPSs, differ in number and positions of chlorine atoms (from 2 to 7), were investigated at pH 8.0. The second-order rate constants (k, M -1 s -1 ) of the reactions varied with the numbers and positions of chlorine atoms and appeared to be related with standard Gibbs free energy of formation (Δ f G 0 ) of PCDPSs. Degradation experiments in the presence of ions and humic acid demonstrated complete removal of PeCDPS by Fe(VI) in minutes. Pathways of the reaction were investigated by identifying oxidized products (OPs) of the reaction between Fe(VI) and 2,2',3',4,5-pentachlorodiphenyl sulfide (PeCDPS) at pH 8.0. Pathways of oxidation involved major pathway of attack on sulfur(II) by Fe(VI) in steps to yield sulfoxide type products, and subsequent breakage of C-S bond with the formation of sulfonic acid-containing trichloro compound. Minor pathways were hydroxylation of benzene ring and substitution of chlorine atom with hydroxyl group. Estimation of toxicity of OPs of the oxidation of PeCDPS by Fe(VI) suggested the decreased toxicity from the parent contaminant. Copyright © 2018. Published by Elsevier Ltd.

  7. Enhanced Cr(VI) removal by polyethylenimine- and phosphorus-codoped hierarchical porous carbons.

    PubMed

    Chen, Shixia; Wang, Jun; Wu, Zeliang; Deng, Qiang; Tu, Wenfeng; Dai, Guiping; Zeng, Zheling; Deng, Shuguang

    2018-08-01

    The amino- and phosphorus-codoped (N,P-codoped) porous carbons derived from oil-tea shells were facilely fabricated through a combination of phosphoric acid (H 3 PO 4 ) activation and amino (polyethylenimine, PEI) modification method. The as-synthesized carbon adsorbents were systematically characterized and evaluated for Cr(VI) removal in aqueous solutions. The relationship between adsorbent properties and adsorption behaviors was illustrated. Moreover, the influences of contact time, initial Cr(VI) concentration, pH, coexisting anions and temperature were also investigated. The adsorption behavior of Cr(VI) could be perfectly described by the pseudo-second-order kinetic model and Sips adsorption model. The maximum adsorption capacity of Cr(VI) on the carbon adsorbents synthesized in this work was 355.0 mg/g, and this excellent Cr(VI) capacity could be sustained with other coexisting anions. In addition to high surface area and suitable pore size distribution, the high Cr(VI) removal capacity is induced by rich heteroatoms incorporation and the Cr(VI) removal mechanism was clearly illustrated. Furthermore, the continuous column breakthrough experiment on obtained N,P-codoped carbon was conducted and well fitted by the Thomas model. This work revealed that PEI modification and P-containing groups could significantly enhance Cr(VI) adsorption capacity and make these N,P-codoped biomass-derived carbons potent adsorbents in practical water treatment applications. Copyright © 2018 Elsevier Inc. All rights reserved.

  8. Contribution of extracellular polymeric substances from Shewanella sp. HRCR-1 biofilms to U(VI) immobilization.

    PubMed

    Cao, Bin; Ahmed, Bulbul; Kennedy, David W; Wang, Zheming; Shi, Liang; Marshall, Matthew J; Fredrickson, Jim K; Isern, Nancy G; Majors, Paul D; Beyenal, Haluk

    2011-07-01

    The goal of this study was to quantify the contribution of extracellular polymeric substances (EPS) to U(VI) immobilization by Shewanella sp. HRCR-1. Through comparison of U(VI) immobilization using cells with bound EPS (bEPS) and cells with minimal EPS, we show that (i) bEPS from Shewanella sp. HRCR-1 biofilms contribute significantly to U(VI) immobilization, especially at low initial U(VI) concentrations, through both sorption and reduction; (ii) bEPS can be considered a functional extension of the cells for U(VI) immobilization and they likely play more important roles at lower initial U(VI) concentrations; and (iii) the U(VI) reduction efficiency is dependent upon the initial U(VI) concentration and decreases at lower concentrations. To quantify the relative contributions of sorption and reduction to U(VI) immobilization by EPS fractions, we isolated loosely associated EPS (laEPS) and bEPS from Shewanella sp. HRCR-1 biofilms grown in a hollow fiber membrane biofilm reactor and tested their reactivity with U(VI). We found that, when reduced, the isolated cell-free EPS fractions could reduce U(VI). Polysaccharides in the EPS likely contributed to U(VI) sorption and dominated the reactivity of laEPS, while redox active components (e.g., outer membrane c-type cytochromes), especially in bEPS, possibly facilitated U(VI) reduction.

  9. Inactivation of bacteriophage MS2 with potassium ferrate(VI).

    PubMed

    Hu, Lanhua; Page, Martin A; Sigstam, Therese; Kohn, Tamar; Mariñas, Benito J; Strathmann, Timothy J

    2012-11-06

    Ferrate [Fe(VI); FeO(4)(2-)] is an emerging oxidizing agent capable of controlling chemical and microbial water contaminants. Here, inactivation of MS2 coliphage by Fe(VI) was examined. The inactivation kinetics observed in individual batch experiments was well described by a Chick-Watson model with first-order dependences on disinfectant and infective phage concentrations. The inactivation rate constant k(i) at a Fe(VI) dose of 1.23 mgFe/L (pH 7.0, 25 °C) was 2.27(±0.05) L/(mgFe × min), corresponding to 99.99% inactivation at a Ct of ~4 (mgFe × min)/L. Measured k(i) values were found to increase with increasing applied Fe(VI) dose (0.56-2.24 mgFe/L), increasing temperature (5-30 °C), and decreasing pH conditions (pH 6-11). The Fe(VI) dose effect suggested that an unidentified Fe byproduct also contributed to inactivation. Temperature dependence was characterized by an activation energy of 39(±6) kJ mol(-1), and k(i) increased >50-fold when pH decreased from 11 to 6. The pH effect was quantitatively described by parallel reactions with HFeO(4)(-) and FeO(4)(2-). Mass spectrometry and qRT-PCR analyses demonstrated that both capsid protein and genome damage increased with the extent of inactivation, suggesting that both may contribute to phage inactivation. Capsid protein damage, localized in the two regions containing oxidant-sensitive cysteine residues, and protein cleavage in one of the two regions may facilitate genome damage by increasing Fe(VI) access to the interior of the virion.

  10. Research progress in the use of ferrate(VI) for the environmental remediation.

    PubMed

    Jiang, J Q

    2007-07-31

    The aim of this paper is to review the research progress of using ferrate(VI) in following fields of environmental remediation: (1) water disinfection; (2) degradation of synthetic organic pollutants; (3) treatment of emerging organic pollutants; (4) oxidation of inorganic pollutants; (5) removing humic substance; (6) wastewater treatment and disinfection; and (7) sewage sludge treatment. Whilst the superior performance of potassium ferrate(VI) as an oxidant/disinfectant for the environmental remediation has been demonstrated in various recent researches, challenges have existed to the implementation of ferrate(VI) technology in full-scale water, wastewater and sewage sludge treatment owing to either the instability property of a ferrate(VI) solution or a high preparation cost of a solid ferrate(VI). In addition to this, there are some fundamental issues which have not yet been studied thoroughly which are crucial for the implementation of ferrate(VI)-these lead to the future research work recommended by this paper.

  11. Rehabilitation with 4 zygomatic implants with a new surgical protocol using ultrasonic technique.

    PubMed

    Mozzati, Marco; Mortellaro, Carmen; Arata, Valentina; Gallesio, Giorgia; Previgliano, Valter

    2015-05-01

    When the residual bone crest cannot allow the placement of standard implants, the treatment for complete arch rehabilitation of severely atrophic maxillae can be performed with 4 zygomatic implants (ZIs) and immediate function with predictable results in terms of aesthetics, function, and comfort for the patient. However, even if ZIs' rehabilitations showed a good success rate, this surgery is difficult and need a skillful operator. Complications in this kind of rehabilitation are not uncommon; the main difficulties can be related to the reduced surgical visibility and instrument control in a critical anatomic area. All the surgical protocols described in the literature used drilling techniques. Furthermore, the use of ultrasonic instruments in implant surgery compared with drilling instruments have shown advantages in many aspects of surgical procedures, tissues management, enhancement of control, surgical visualization, and healing. The aim of this study was to report on the preliminary experience using ultrasound technique for ZIs surgery in terms of safety and technical improvement. Ten consecutive patients with severely atrophic maxilla have been treated with 4 ZIs and immediate complete arch acrylic resin provisional prostheses. The patients were followed up from 30 to 32 months evaluating implant success, prosthetic success, and patient satisfaction with a questionnaire. No implants were lost during the study period, with a 100% implant and prosthetic success rate. Within the limitations of this preliminary study, these data indicate that ultrasonic implant site preparation for ZIs can be a good alternative to the drilling technique and an improvement for the surgeon.

  12. Characterization of U(VI)-carbonato ternary complexes on hematite: EXAFS and electrophoretic mobility measurements

    USGS Publications Warehouse

    Bargar, John R.; Reitmeyer, Rebecca; Lenhart, John J.; Davis, James A.

    2000-01-01

    We have measured U(VI) adsorption on hematite using EXAFS spectroscopy and electrophoresis under conditions relevant to surface waters and aquifers (0.01 to 10 μM dissolved uranium concentrations, in equilibrium with air, pH 4.5 to 8.5). Both techniques suggest the existence of anionic U(VI)-carbonato ternary complexes. Fits to EXAFS spectra indicate that U(VI) is simultaneously coordinated to surface FeO6 octahedra and carbonate (or bicarbonate) ligands in bidentate fashions, leading to the conclusion that the ternary complexes have an inner-sphere metal bridging (hematite-U(VI)-carbonato) structure. Greater than or equal to 50% of adsorbed U(VI) was comprised of monomeric hematite-U(VI)-carbonato ternary complexes, even at pH 4.5. Multimeric U(VI) species were observed at pH ≥ 6.5 and aqueous U(VI) concentrations approximately an order of magnitude more dilute than the solubility of crystalline β-UO2(OH)2. Based on structural constraints, these complexes were interpreted as dimeric hematite-U(VI)-carbonato ternary complexes. These results suggest that Fe-oxide-U(VI)-carbonato complexes are likely to be important transport-limiting species in oxic aquifers throughout a wide range of pH values.

  13. Cr(VI) Adsorption on Red Mud Modified by Lanthanum: Performance, Kinetics and Mechanisms

    PubMed Central

    Cui, You-Wei; Li, Jie; Du, Zhao-Fu; Peng, Yong-Zhen

    2016-01-01

    Water pollution caused by the highly toxic metal hexavalent chromium (Cr(VI)) creates significant human health and ecological risks. In this study, a novel adsorbent was used to treat Cr(VI)-containing wastewater; the adsorbent was prepared using red mud (RM) generated from the alumina production industry and the rare earth element lanthanum. This study explored adsorption performance, kinetics, and mechanisms. Results showed that the adsorption kinetics of the RM modified by lanthanum (La-RM), followed the pseudo-second-order model, with a rapid adsorption rate. Cr(VI) adsorption was positively associated with the absorbent dose, pH, temperature, and initial Cr(VI) concentration; coexisting anions had little impact. The maximum Cr(VI) adsorption capacity was 17.35 mg/g. Cr(VI) adsorption on La-RM was a mono-layer adsorption pattern, following the Langmuir isotherm model. Thermodynamic parameters showed the adsorption was spontaneous and endothermic. The adsorption of Cr(VI) on La-RM occurred as a result of LaOCl formation on the RM surface, which in turn further reacted with Cr(VI) in the wastewater. This study highlighted a method for converting industrial waste into a valuable material for wastewater treatment. The novel absorbent could be used as a potential adsorbent for treating Cr(VI)-contaminating wastewater, due to its cost-effectiveness and high adsorption capability. PMID:27658113

  14. Cr(VI) remediation by enriched sediment with anthraquinone-2,6-disulfonate as electron shuttles

    NASA Astrophysics Data System (ADS)

    Chen, Hong; Li, Xiaojuan; Xu, Zhiwei

    Hexavalent chromium (Cr(VI)) is a priority pollutant in the USA and many other countries. This study investigated the simultaneous remediation of Cr(VI) in sediment enriched with quinone-reducing microorganisms via a closely coupled, biotic-abiotic pathway. The results showed that Cr(VI) remediation was achieved by sediment adsorption and reduction of quinone-reducing microorganism. Moreover, microorganism reduction of Cr(VI) could be continued when sediment adsorption was saturated after long-term Cr(VI) remediation. The acetate and anthraquinone-2,6-disulfonate (AQDS), which acted as exogenous carbon and electron shuttle, respectively, were two crucial factors. The optimum concentrations of acetate and AQDS were 5 mM and 1 mM when the initial Cr(VI) concentration was 10 mg/L. AQDS was recycled, and it acted in a catalytic-type manner for the bacterial reduction of Cr(VI). Thus, biological humus reduction might provide an extensive pathway for the sequestration and detoxification of Cr(VI) in anaerobic soils, water, and industrial effluents.

  15. Quantitative evaluation of ViOptix's tissue oximeter in an ex-vivo animal model

    NASA Astrophysics Data System (ADS)

    Mao, Jimmy J. M.; Xu, Ronald; Lash, Bob; Wright, Leigh

    2008-02-01

    We evaluate the performance of ODISsey TM Tissue Oximeter (ViOptix, Inc., Fremont, CA) against co-oximeter. Concurrent oxygen saturation measurements were made in three dog limbs surgically removed and perfused with an extracorporeal blood circulation system. Oxygen saturation was adjusted in steps ranging from 95% down to 5% as monitored by the co-oximeter. The co-oximeter was used to measure the oxygen saturation of the whole blood drawn from both the arterial and the venous ports of the limb. The tissue oxygenation measured by the ODISsey TM tissue oximeter was compared with the average of the arterial and the venous blood oxygenation measured by the co-oximeter. Linear correlation was observed between the average oxygenation given by the co-oximeter and the ODISseyTM readings, with a root-mean-square difference of 7.6% and the correlation coefficient of 0.941, calculated from N = 194 data points.

  16. Intervening O vi Quasar Absorption Systems at Low Redshift: A Significant Baryon Reservoir.

    PubMed

    Tripp; Savage; Jenkins

    2000-05-01

    Far-UV echelle spectroscopy of the radio-quiet QSO H1821+643 (zem=0.297), obtained with the Space Telescope Imaging Spectrograph (STIS) at approximately 7 km s-1 resolution, reveals four definite O vi absorption-line systems and one probable O vi absorber at 0.15vi absorbers are located near galaxies and are highly displaced from the quasar in redshift; these are likely intervening systems unrelated to the background QSO. In the case of the strong O vi system at zabs=0.22497, multiple components are detected in Si iii and O vi as well as H i Lyman series lines, and the differing component velocity centroids and b-values firmly establish that this is a multiphase absorption system. A weak O vi absorber is detected at zabs=0.22637, i.e., offset by approximately 340 km s-1 from the zabs=0.22497 system. Lyalpha absorption is detected at zabs=0.22613, but no Lyalpha absorption is significantly detected at 0.22637. Other weak O vi absorbers at zabs=0.24531 and 0.26659 and the probable O vi system at 0.21326 have widely diverse O vi/H i column density ratios with N(O vi)/N(H i) ranging from vi absorbers with rest equivalent width greater than 30 mÅ in the H1821+643 spectrum is remarkably high, dN&solm0;dz approximately 48, which implies with a high (90%) confidence that it is greater than 17 in the low-redshift intergalactic medium. We conservatively estimate that the cosmological mass density of the O vi systems is Omegab(Ovi&parr0; greater, similar0.0008 h-175. With an assumed metallicity of 1/10 solar and a conservative assumption that the fraction of oxygen in the O vi ionization stage is 0.2, we obtain Omegab(Ovi&parr0; greater, similar0.004 h-175. This is comparable to the combined cosmological mass density of stars and cool gas in galaxies and X-ray-emitting gas in galaxy clusters at low redshift.

  17. Implementing AORN recommended practices for prevention of retained surgical items.

    PubMed

    Goldberg, Judith L; Feldman, David L

    2012-02-01

    Retention of a surgical item is a preventable event that can result in patient injury. AORN's "Recommended practices for prevention of retained surgical items" emphasizes the importance of using a multidisciplinary approach for prevention. Procedures should include counts of soft goods, needles, miscellaneous items, and instruments, and efforts should be made to prevent retention of fragments of broken devices. If a count discrepancy occurs, the perioperative team should follow procedures to locate the missing item. Perioperative leaders may consider the use of adjunct technologies such as bar-code scanning, radio-frequency detection, and radio-frequency identification. Ambulatory and hospital patient scenarios are included to exemplify appropriate strategies for preventing retained surgical items. Copyright © 2012 AORN, Inc. Published by Elsevier Inc. All rights reserved.

  18. Vertebral Compression Fractures after Lumbar Instrumentation.

    PubMed

    Granville, Michelle; Berti, Aldo; Jacobson, Robert E

    2017-09-29

    Lumbar spinal stenosis (LSS) is primarily found in an older population. This is a similar demographic group that develops both osteoporosis and vertebral compression fractures (VCF). This report reviewed a series of patients treated for VCF that had previous lumbar surgery for symptomatic spinal stenosis. Patients that only underwent laminectomy or fusion without instrumentation had a similar distribution of VCF as the non-surgical population in the mid-thoracic, or lower thoracic and upper lumbar spine. However, in the patients that had previous short-segment spinal instrumentation, fractures were found to be located more commonly in the mid-lumbar spine or sacrum adjacent to or within one or two spinal segments of the spinal instrumentation. Adjacent-level fractures that occur due to vertebral osteoporosis after long spinal segment instrumentation has been discussed in the literature. The purpose of this report is to highlight the previously unreported finding of frequent lumbar and sacral osteoporotic fractures in post-lumbar instrumentation surgery patients. Important additional factors found were lack of preventative medical treatment for osteoporosis, and secondary effects related to inactivity, especially during the first year after surgery.

  19. Contribution of Extracellular Polymeric Substances from Shewanella sp. HRCR-1 Biofilms to U(VI) Immobilization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cao, Bin; Ahmed, B.; Kennedy, David W.

    2011-06-05

    The goal of this study was to quantify the contribution of extracellular polymeric substances (EPS) in U(VI) immobilization by Shewanella sp. HRCR-1. Through comparison of U(VI) immobilization using cells with bound EPS (bEPS) and cells without EPS, we showed that i) bEPS from Shewanella sp. HRCR-1 biofilms contributed significantly to U(VI) immobilization, especially at low initial U(VI) concentrations, through both sorption and reduction; ii) bEPS could be considered as a functional extension of the cells for U(VI) immobilization and they likely play more important roles at initial U(VI) concentrations; and iii) U(VI) reduction efficiency was found to be dependent uponmore » initial U(VI) concentration and the efficiency decreased at lower concentrations. To quantify relative contribution of sorption and reduction in U(VI) immobilization by EPS fractions, we isolated loosely associated EPS (laEPS) and bEPS from Shewanella sp. HRCR-1 biofilms grown in a hollow fiber membrane biofilm reactor and tested their reactivity with U(V). We found that, when in reduced form, the isolated cell-free EPS fractions could reduce U(VI). Polysaccharides in the EPS likely contributed to U(VI) sorption and dominated reactivity of laEPS while redox active components (e.g., outer membrane c-type cytochromes), especially in bEPS, might facilitate U(VI) reduction.« less

  20. Bicarbonate Impact on U(VI) Bioreduction in a Shallow Alluvial Aquifer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Long, Philip E.; Williams, Kenneth H.; Davis, James A.

    Field-scale biostimulation and desorption tracer experiments conducted in a uranium (U) contaminated, shallow alluvial aquifer have provided insight into the coupling of microbiology, biogeochemistry, and hydrogeology that control U mobility in the subsurface. Initial experiments successfully tested the concept that Fe-reducing bacteria such as Geobacter sp. could enzymatically reduce soluble U(VI) to insoluble U(IV) during in situ electron donor amendment (Anderson et al. 2003, Williams et al. 2011). In parallel, in situ desorption tracer tests using bicarbonate amendment demonstrated rate-limited U(VI) desorption (Fox et al. 2012). These results and prior laboratory studies underscored the importance of enzymatic U(VI)-reduction and suggestedmore » the ability to combine desorption and bioreduction of U(VI). Here we report the results of a new field experiment in which bicarbonate-promoted uranium desorption and acetate amendment were combined and compared to an acetate amendment-only experiment in the same experimental plot. Results confirm that bicarbonate amendment to alluvial aquifer desorbs U(VI) and increases the abundance of Ca-uranyl-carbonato complexes. At the same time, that the rate of acetate-promoted enzymatic U(VI) reduction was greater in the presence of added bicarbonate in spite of the increased dominance of Ca-uranyl-carbonato aqueous complexes. A model-simulated peak rate of U(VI) reduction was ~3.8 times higher during acetate-bicarbonate treatment than under acetate-only conditions. Lack of consistent differences in microbial community structure between acetate-bicarbonate and acetate-only treatments suggest that a significantly higher rate of U(VI) reduction the bicarbonate-impacted sediment may be due to a higher intrinsic rate of microbial reduction induced by elevated concentrations of the bicarbonate oxyanion. The findings indicate that bicarbonate amendment may be useful in improving the engineered bioremediation of uranium in aquifers.« less

  1. Bicarbonate impact on U(VI) bioreduction in a shallow alluvial aquifer

    NASA Astrophysics Data System (ADS)

    Long, Philip E.; Williams, Kenneth H.; Davis, James A.; Fox, Patricia M.; Wilkins, Michael J.; Yabusaki, Steven B.; Fang, Yilin; Waichler, Scott R.; Berman, Elena S. F.; Gupta, Manish; Chandler, Darrell P.; Murray, Chris; Peacock, Aaron D.; Giloteaux, Ludovic; Handley, Kim M.; Lovley, Derek R.; Banfield, Jillian F.

    2015-02-01

    Field-scale biostimulation and desorption tracer experiments conducted in a uranium (U) contaminated, shallow alluvial aquifer have provided insight into the coupling of microbiology, biogeochemistry, and hydrogeology that control U mobility in the subsurface. Initial experiments successfully tested the concept that Fe-reducing bacteria such as Geobacter sp. could enzymatically reduce soluble U(VI) to insoluble U(IV) during in situ electron donor amendment (Anderson et al., 2003; Williams et al., 2011). In parallel, in situ desorption tracer tests using bicarbonate amendment demonstrated rate-limited U(VI) desorption (Fox et al., 2012). These results and prior laboratory studies underscored the importance of enzymatic U(VI)-reduction and suggested the ability to combine desorption and bioreduction of U(VI). Here we report the results of a new field experiment in which bicarbonate-promoted uranium desorption and acetate amendment were combined and compared to an acetate amendment-only experiment in the same experimental plot. Results confirm that bicarbonate amendment to alluvial aquifer sediments desorbs U(VI) and increases the abundance of Ca-uranyl-carbonato complexes. At the same time, the rate of acetate-promoted enzymatic U(VI) reduction was greater in the presence of added bicarbonate in spite of the increased dominance of Ca-uranyl-carbonato aqueous complexes. A model-simulated peak rate of U(VI) reduction was ∼3.8 times higher during acetate-bicarbonate treatment than under acetate-only conditions. Lack of consistent differences in microbial community structure between acetate-bicarbonate and acetate-only treatments suggest that a significantly higher rate of U(VI) reduction in the bicarbonate-impacted sediment may be due to a higher intrinsic rate of microbial reduction induced by elevated concentrations of the bicarbonate oxyanion. The findings indicate that bicarbonate amendment may be useful in improving the engineered bioremediation of uranium in

  2. [Kinetics modeling and reaction mechanism of ferrate(VI) oxidation of triclosan].

    PubMed

    Yang, Bin; Ying, Guang-Guo; Zhao, Jian-Liang

    2011-09-01

    Triclosan (TCS) is a broad-spectrum antibacterial agent widely used in many personal care products. We investigated oxidation of TCS by aqueous ferrate Fe(VI) to determine reaction kinetics, interpreted the reaction mechanism by a linear free-energy relationship, and evaluated the degradation efficiency. Second-order reaction kinetics was used to model Fe (VI) oxidation of TCS, with the apparent second-order rate constant (k(app)) being 531.9 L x (mol x s)(-1) at pH 8.5 and (24 +/- 1) degrees C. The half life (t1/2) is 25.8 s for an Fe( VI) concentration of 10 mg x L(-1). The rate constants of the reaction decrease with increasing pH values. These pH-dependent variations in k(app) could be distributed by considering species-specific reactions between Fe(VI) species and acid-base species of an ionizable TCS. Species-specific second-order reaction rate constants, k, were determined for reaction of HFeO4(-) with each of TCS's acid-base species. The value of k determined for neutral TCS was (4.1 +/- 3.5) x 10(2) L x (mol x s)(-1), while that measured for anionic TCS was (1.8 +/- 0.1) x 10(4) L x (mol x s)(-1). The reaction between HFeO4(-) and the dissociated TCS controls the overall reaction. A linear free-energy relationship illustrated the electrophilic oxidation mechanism. Fe (VI) reacts initially with TCS by electrophilic attack at the latter's phenol moiety. At a n[Fe(VI)]: n(TCS) > 7: 1, complete removal of TCS was achieved. And lower concentration of the humic acid could enhance the k(app) of Fe( VI) with TCS. In conclusion, Fe(VI) oxidation technology appears to be a promising tool for applications of WWTPs effluents and other decontamination processes.

  3. Hereditary motor and sensory neuropathy type VI with optic atrophy.

    PubMed

    Voo, Irene; Allf, Bryan E; Udar, Nitin; Silva-Garcia, Rosamaria; Vance, Jeffrey; Small, Kent W

    2003-10-01

    To present the detailed clinical findings of a large family with hereditary motor and sensory neuropathy type VI (HMSN VI), a syndrome featuring optic atrophy. Observational case series. A detailed history was obtained and physical examination was made of the extended family of the proband for evidence of neurologic dysfunction. The OPA1 gene was screened for mutations by direct DNA sequencing. Twelve of 97 family members examined are affected with signs of HMSN VI. Three other members have either optic atrophy or peripheral neuropathy, thus allowing an appreciation of the full clinical spectrum of disease. No mutations were found in the OPA1 gene. This family demonstrates the variable expressivity of this disorder as well as incomplete penetrance. This is the largest known family with HMSN VI. No association was found with changes in the OPA1 gene.

  4. Multimodality instrument for tissue characterization

    NASA Technical Reports Server (NTRS)

    Mah, Robert W. (Inventor); Andrews, Russell J. (Inventor)

    2004-01-01

    A system with multimodality instrument for tissue identification includes a computer-controlled motor driven heuristic probe with a multisensory tip. For neurosurgical applications, the instrument is mounted on a stereotactic frame for the probe to penetrate the brain in a precisely controlled fashion. The resistance of the brain tissue being penetrated is continually monitored by a miniaturized strain gauge attached to the probe tip. Other modality sensors may be mounted near the probe tip to provide real-time tissue characterizations and the ability to detect the proximity of blood vessels, thus eliminating errors normally associated with registration of pre-operative scans, tissue swelling, elastic tissue deformation, human judgement, etc., and rendering surgical procedures safer, more accurate, and efficient. A neural network program adaptively learns the information on resistance and other characteristic features of normal brain tissue during the surgery and provides near real-time modeling. A fuzzy logic interface to the neural network program incorporates expert medical knowledge in the learning process. Identification of abnormal brain tissue is determined by the detection of change and comparison with previously learned models of abnormal brain tissues. The operation of the instrument is controlled through a user friendly graphical interface. Patient data is presented in a 3D stereographics display. Acoustic feedback of selected information may optionally be provided. Upon detection of the close proximity to blood vessels or abnormal brain tissue, the computer-controlled motor immediately stops probe penetration. The use of this system will make surgical procedures safer, more accurate, and more efficient. Other applications of this system include the detection, prognosis and treatment of breast cancer, prostate cancer, spinal diseases, and use in general exploratory surgery.

  5. Determination of Cr(III) solids formed by reduction of Cr(VI) in a contaminated fractured bedrock aquifer: evidence for natural attenuation of Cr(VI)

    EPA Science Inventory

    Hexavalent chromium Cr(VI) is toxic and can be highly mobile in many aquifer systems. Redox reactions with naturally occurring minerals and organic compounds can reduce Cr(VI) to Cr(III), forming labile Cr(III) oxyhydroxide precipitates, which is a natural attenuation process. In...

  6. The role of virtual reality in surgical training in otorhinolaryngology.

    PubMed

    Fried, Marvin P; Uribe, José I; Sadoughi, Babak

    2007-06-01

    This article reviews the rationale, current status and future directions for the development and implementation of virtual reality surgical simulators as training tools. The complexity of modern surgical techniques, which utilize advanced technology, presents a dilemma for surgical training. Hands-on patient experience - the traditional apprenticeship method for teaching operations - may not apply because of the learning curve for skill acquisition and patient safety expectation. The paranasal sinuses and temporal bone have intricate anatomy with a significant amount of vital structures either within the surgical field or in close proximity. The current standard of surgical care in these areas involves the use of endoscopes, cameras and microscopes, requiring additional hand-eye coordination, an accurate command of fine motor skills, and a thorough knowledge of the anatomy under magnified vision. A surgeon's disorientation or loss of perspective can lead to complications, often catastrophic and occasionally lethal. These considerations define the ideal environment for surgical simulation; not surprisingly, significant research and validation of simulators in these areas have occurred. Virtual reality simulators are demonstrating validity as training and skills assessment tools. Future prototypes will find application for routine use in teaching, surgical planning and the development of new instruments and computer-assisted devices.

  7. Enhanced abiotic reduction of Cr(VI) in a soil slurry system by natural biomaterial addition.

    PubMed

    Park, Donghee; Ahn, Chi Kyu; Kim, Young Mi; Yun, Yeoung-Sang; Park, Jong Moon

    2008-12-30

    Among various plant-based natural biomaterials, pine bark was chosen as an efficient biomaterial capable of removing toxic Cr(VI) from aqueous solution. XPS spectra indicated that Cr(VI) was abiotically reduced to Cr(III) in both liquid and solid phases. The Cr(VI)-reducing capacity of pine bark was determined as 545 (+/-1.3)mg-Cr(VI)g(-1) of it, which was 8.7 times higher than that of a common chemical Cr(VI)-reductant, FeSO4 x 7H2O. Because pine bark could completely reduce toxic Cr(VI) to less toxic or nontoxic Cr(III) even at neutral pH, it was used as an organic reductant to remediate Cr(VI)-contaminated soil in this study. Soil slurry system using a bottle roller was applied to ex situ slurry-phase remediation experiments. In the soil slurry system, pine bark completely reduced Cr(VI) to Cr(III) and adsorbed the reduced-Cr(III) on its surface. Abiotic remediation rate of Cr(VI)-contaminated soil increased with the increase of pine bark dosage and with the decreases of Cr(VI) and water contents. In conclusion, pine bark can be used to remediate Cr(VI)-contaminated soil efficiently and environmentally friendly.

  8. Cr(VI) Occurrence and Geochemistry in Water From Public-Supply Wells in California

    DOE PAGES

    Izbicki, John A.; Wright, Michael T.; Seymour, Whitney A.; ...

    2015-08-18

    Hexavalent chromium, Cr(VI), in 918 wells sampled throughout California between 2004 and 2012 by the Groundwater Ambient Monitoring and Assessment Program—Priority Basin Project (GAMA—PBP) ranged from less than the study reporting limit (SRL) of 1 microgram per liter (μg/L) to 32 μg/L. Statewide, Cr(VI) was reported in 31 percent of sampled wells and equaled or exceeded the recently established (2014) California Maximum Contaminant Level (MCL) for Cr(VI) of 10 μg/L in 4 percent of sampled wells. Cr(VI) data collected for regulatory purposes overestimate Cr(VI) occurrence. Ninety percent of chromium was present as Cr(VI), which was detected more frequently and atmore » higher concentrations in alkaline (pH > 8), oxic water, and more frequently in agricultural and urban land uses compared to native land uses. Chemical, isotopic (tritium and carbon-14), and noble-gas data show high Cr(VI) in water from wells in alluvial aquifers in the southern California deserts result from long groundwater-residence times and geochemical reactions such as silicate weathering that increase pH, while oxic conditions persist. High Cr(VI) in water from wells in alluvial aquifers along the west-side of the Central Valley results from high-chromium abundance in source rock eroded to form those aquifers, and areal recharge processes (including irrigation return) that mobilize chromium from the unsaturated zone. Cr(VI) co-occurred with oxyanions having similar chemistry, including vanadium, selenium, and uranium. Cr(VI) was positively correlated with nitrate, consistent with increased concentrations in areas of agricultural land use and mobilization of chromium from the unsaturated zone by irrigation return.« less

  9. Cr(VI) occurrence and geochemistry in water from public-supply wells in California

    USGS Publications Warehouse

    Izbicki, John; Wright, Michael; Seymour, Whitney A.; McCleskey, R. Blaine; Fram, Miranda S.; Belitz, Kenneth; Esser, Bradley K.

    2015-01-01

    Hexavalent chromium, Cr(VI), in 918 wells sampled throughout California between 2004 and 2012 by the Groundwater Ambient Monitoring and Assessment-Priority Basin Project (GAMA-PBP) ranged from less than the study reporting limit of 1 microgram per liter (μg/L) to 32 μg/L. Statewide, Cr(VI) was reported in 31 percent of wells and equaled or exceeded the recently established (2014) California Maximum Contaminant Level (MCL) for Cr(VI) of 10 μg/L in 4 percent of wells. Cr(VI) data collected for regulatory purposes overestimated Cr(VI) occurrence compared to spatially-distributed GAMA-PBP data. Ninety percent of chromium was present as Cr(VI), which was detected more frequently and at higher concentrations in alkaline (pH ≥ 8), oxic water; and more frequently in agricultural and urban land uses compared to native land uses. Chemical, isotopic (tritium and carbon-14), and noble-gas data show high Cr(VI) in water from wells in alluvial aquifers in the southern California deserts result from long groundwater-residence times and geochemical reactions such as silicate weathering that increase pH, while oxic conditions persist. High Cr(VI) in water from wells in alluvial aquifers along the west-side of the Central Valley results from high-chromium in source rock eroded to form those aquifers, and areal recharge processes (including irrigation return) that can mobilize chromium from the unsaturated zone. Cr(VI) co-occurred with oxyanions having similar chemistry, including vanadium, selenium, and uranium. Cr(VI) was positively correlated with nitrate, consistent with increased concentrations in areas of agricultural land use and mobilization of chromium from the unsaturated zone by irrigation return.

  10. Characterization of the biochemical-pathway of uranium (VI) reduction in facultative anaerobic bacteria.

    PubMed

    Mtimunye, Phalazane J; Chirwa, Evans M N

    2014-10-01

    Cultures of U(VI) reducing bacteria sourced from abandoned uranium mine tailing dam were evaluated for their ability to reduce U(VI) to U(IV). The species in the cultures reduced U(VI) in solutions with initial U(VI) concentration up to 400mgL(-)(1) under a near neutral pH of 6.5. The electron flow pathway and fate of reduced species was also analysed in the individual species in order to evaluate the potential for control and optimisation of the reduction potential at the biochemical level. The results showed that U(VI) reduction in live cells was completely blocked by the NADH-dehydrogenase inhibitor, rotenone (C23H22O6), and thioredoxin inhibitor, cadmium chloride (CdCl2), showing that U(VI) reduction involves the electron flow through NADH-dehydrogenase, a primary electron donor to the electron transport respiratory (ETR) system. Mass balance analysis of uranium species aided by visual and electron microscopy suggest that most U(VI) reduction occurred on the cell surface of the isolated species. This finding indicates the possibility of easy uranium recovery for beneficial use through biological remediation. Should the U(VI) be reduced inside the cell, recovery would require complete disruption of the cells and therefore would be difficult. The study contributes new knowledge on the underlying mechanisms in the U(VI) reduction in facultative anaerobes. Copyright © 2014 Elsevier Ltd. All rights reserved.

  11. Evaluating the Impact of Radio Frequency Identification Retained Surgical Instruments Tracking on Patient Safety: Literature Review.

    PubMed

    Schnock, Kumiko O; Biggs, Bonnie; Fladger, Anne; Bates, David W; Rozenblum, Ronen

    2017-02-22

    Retained surgical instruments (RSI) are one of the most serious preventable complications in operating room settings, potentially leading to profound adverse effects for patients, as well as costly legal and financial consequences for hospitals. Safety measures to eliminate RSIs have been widely adopted in the United States and abroad, but despite widespread efforts, medical errors with RSI have not been eliminated. Through a systematic review of recent studies, we aimed to identify the impact of radio frequency identification (RFID) technology on reducing RSI errors and improving patient safety. A literature search on the effects of RFID technology on RSI error reduction was conducted in PubMed and CINAHL (2000-2016). Relevant articles were selected and reviewed by 4 researchers. After the literature search, 385 articles were identified and the full texts of the 88 articles were assessed for eligibility. Of these, 5 articles were included to evaluate the benefits and drawbacks of using RFID for preventing RSI-related errors. The use of RFID resulted in rapid detection of RSI through body tissue with high accuracy rates, reducing risk of counting errors and improving workflow. Based on the existing literature, RFID technology seems to have the potential to substantially improve patient safety by reducing RSI errors, although the body of evidence is currently limited. Better designed research studies are needed to get a clear understanding of this domain and to find new opportunities to use this technology and improve patient safety.

  12. 3D tracking of laparoscopic instruments using statistical and geometric modeling.

    PubMed

    Wolf, Rémi; Duchateau, Josselin; Cinquin, Philippe; Voros, Sandrine

    2011-01-01

    During a laparoscopic surgery, the endoscope can be manipulated by an assistant or a robot. Several teams have worked on the tracking of surgical instruments, based on methods ranging from the development of specific devices to image processing methods. We propose to exploit the instruments' insertion points, which are fixed on the patients abdominal cavity, as a geometric constraint for the localization of the instruments. A simple geometric model of a laparoscopic instrument is described, as well as a parametrization that exploits a spherical geometric grid, which offers attracting homogeneity and isotropy properties. The general architecture of our proposed approach is based on the probabilistic Condensation algorithm.

  13. Mobilization of Cr(VI) from chromite ore processing residue through acid treatment.

    PubMed

    Tinjum, James M; Benson, Craig H; Edil, Tuncer B

    2008-02-25

    Batch leaching studies on chromite ore processing residue (COPR) were performed using acids to investigate leaching of hexavalent chromium, Cr(VI), with respect to particle size, reaction time, and type of acid (HNO(3) and H(2)SO(4)). Aqueous Cr(VI) is maximized at approximately 0.04 mol Cr(VI) per kg of dry COPR at pH 7.6-8.1. Cr(VI) mobilized more slowly for larger particles, and the pH increased with time and increased more rapidly for smaller particles, suggesting that rate limitations occur in the solid phase. With H(2)SO(4), the pH stabilized at a higher value (8.8 for H(2)SO(4) vs. 8.0 for HNO(3)) and more rapidly (16 h vs. 30 h), and the differences in pH for different particle sizes were smaller. The acid neutralization capacity (ANC) of COPR is very large (8 mol HNO(3) per kg of dry COPR for a stable eluate pH of 7.5). Changes to the elemental and mineralogical composition and distribution in COPR particles after mixing with acid indicate that Cr(VI)-bearing solids dissolved. However, concentrations of Cr(VI) >2800 mg kg(-1) (>50% of the pre-treatment concentration) were still found after mixing with acid, regardless of the particle size, reaction time, or type of acid used. The residual Cr(VI) appears to be partially associated with poorly-ordered Fe and Al oxyhydroxides that precipitated in the interstitial areas of COPR particles. Remediation strategies that use HNO(3) or H(2)SO(4) to neutralize COPR or to maximize Cr(VI) in solution are likely to require extensive amounts of acid, may not mobilize all of the Cr(VI), and may require extended contact time, even under well-mixed conditions.

  14. Bioreduction of U(VI) and stability of immobilized uranium under suboxic conditions.

    PubMed

    Hu, Nan; Ding, De-xin; Li, Shi-mi; Tan, Xiang; Li, Guang-yue; Wang, Yong-dong; Xu, Fei

    2016-04-01

    In order to study the bioreduction of U(VI) and stability of immobilized uranium under suboxic conditions, microcosm were amended with ethanol, lactate and glucose, and incubated under suboxic conditions. During the incubation, total dissolved U in amended microcosms decreased from 0.95 mg/L to 0.03 mg/L. Pyrosequencing results showed that, the proportion of anaerobic microorganisms capable of reducing U(VI) under suboxic conditions was small compared with that under anoxic conditions; the proportion of aerobic and facultative anaerobic microorganisms capable of consuming the dissolved oxygen was large; and some of the facultative anaerobic microorganisms could reduce U(VI). These results indicated that different microbial communities were responsible for the bioreduction of U(VI) under suboxic and anoxic conditions. After the electron donors were exhausted, total dissolved U in the amended microcosms remained unchanged, while the U(VI)/U(IV) ratio in the solid phase of sediments increased obviously. This implied that the performance of bioreduction of the U(VI) can be maintained under suboxic condition. Copyright © 2016 Elsevier Ltd. All rights reserved.

  15. Oxidation of diclofenac by potassium ferrate (VI): reaction kinetics and toxicity evaluation.

    PubMed

    Wang, Yingling; Liu, Haijin; Liu, Guoguang; Xie, Youhai; Gao, Shuyan

    2015-02-15

    The reaction kinetics and toxicity of diclofenac (DCF) oxidation by ferrate (VI) under simulated water disinfection conditions were investigated. Experimental results indicated that the reaction between DCF and Fe(VI) followed first-order kinetics with respect to each reactant. Furthermore, the effects of pH and temperature on DCF oxidation by Fe(VI) were elucidated using a systematic examination. The apparent second-order rate constants (kapp) increased significantly from 2.54 to 11.6M(-1)s(-1), as the pH of the solution decreased from 11.0 to 7.0, and the acid-base equilibriums of Fe(VI) and DCF were proposed to explain the pH dependence of kapp. The acute toxicity of DCF solution during Fe(VI) oxidation was evaluated using a Microtox bioassay. Overall, the DCF degradation process resulted in a rapid increase of the inhibition rate of luminescent bacteria. These toxicity tests suggest that the formation of enhanced toxic intermediates during the Fe(VI) disinfection process may pose potential health risk to consumers. Copyright © 2014 Elsevier B.V. All rights reserved.

  16. [Mechanism and promotion effect of K+ on yield of Fe(VI)].

    PubMed

    Zhang, Yan-Ping; Xu, Guo-Ren; Li, Gui-Bai

    2008-03-01

    The mechanism and promotion effects of K+ on the yield of Fe(VI) were studied during the reaction of forming ferrate. The experiment results showed that K+ is far better than Na+ for the preparation of Fe(VI) at temperatures higher than 50 degrees C. The optimal temperature for the preparation of Fe(VI) with K+ is 65 degrees C. During the reaction, the yield of ferrate increases with the concentration of K+, and the promotion effect of K+ is obviously with ferric nitrate dosage increase. The Fe(VI) concentration prepared with 4.4 mol/L KOH is 0.05 mol/L at 85 g/L ferric nitrate; and which achieves 0.15 mol/L when added 2 mol/L K+. The promotion effect of K+ on the yield of ferrate is remarkable when ferric nitrate dosage is higher than 75 g/L, reaction temperature is below 55 degrees C and ClO(-) concentration is lower than 1.16 mol/L. The K+ can substitute for partly alkalinity and reduce the concentration of OH(-) in the reaction solution. During the reaction, the K+ can enwrap around FeO4(2-) that can reduce the contact between Fe(3+) and FeO4(2-), and decrease the catalysis effect of Fe(3+) on FeO4(2-). At the same time, K+ can react with FeO4(2-) to form solid K4FeO4, whichwill lower the Fe(VI) concentration, decrease the decomposition rate of Fe(VI), enhance the stability and improve the yield of Fe(VI).

  17. Clinical and serological responses following primary and booster immunization with Salmonella typhi Vi capsular polysaccharide vaccines.

    PubMed

    Keitel, W A; Bond, N L; Zahradnik, J M; Cramton, T A; Robbins, J B

    1994-01-01

    Clinical and serum antibody responses following intramuscular injection of two formulations of Salmonella typhi Vi capsular polysaccharide (Vi) were assessed in a double-blind evaluation. Healthy adults were randomly assigned to receive a 25 micrograms dose of liquid (Vi-Liq; n = 182) or freeze-dried Vi vaccine (Vi-Lyoph; n = 55), or placebo (n = 86). Erythema and/or induration > or = 1 cm in diameter at the injection site developed in 13/182 (7%) of Vi-Liq and 3/55 (5%) of Vi-Lyoph recipients (not significant, n.s.). Fever (oral temperature > or = 100 degrees F (37.8 degrees C)) occurred in < 2% of vaccinees. The frequencies of rises of fourfold or greater and of maximal Vi antibody levels were similar in the two vaccine groups. Fourfold or greater rises in serum Vi antibody levels (RIA) developed in 53% of Vi-Lyoph and 60% of Vi-Liq recipients by 1 week (n.s.), and 98 and 93%, respectively, by 1 month (n.s.). The frequencies of adverse reactions and mean Vi antibody levels following booster immunization with Vi-Liq 27 to 34 months after primary immunization (n = 55) were similar to those observed following primary immunization, although subjects given a booster dose were more likely to develop local reactions > or = 1 cm in diameter than those given a first dose (10/55 versus 13/182, p = 0.013 by the chi 2 test). Primary and booster immunizations with the Vi vaccines are well tolerated in healthy adults; mean Vi antibody levels remain significantly elevated for up to 34 months after primary immunization.

  18. Precision instrument placement using a 4-DOF robot with integrated fiducials for minimally invasive interventions

    NASA Astrophysics Data System (ADS)

    Stenzel, Roland; Lin, Ralph; Cheng, Peng; Kronreif, Gernot; Kornfeld, Martin; Lindisch, David; Wood, Bradford J.; Viswanathan, Anand; Cleary, Kevin

    2007-03-01

    Minimally invasive procedures are increasingly attractive to patients and medical personnel because they can reduce operative trauma, recovery times, and overall costs. However, during these procedures, the physician has a very limited view of the interventional field and the exact position of surgical instruments. We present an image-guided platform for precision placement of surgical instruments based upon a small four degree-of-freedom robot (B-RobII; ARC Seibersdorf Research GmbH, Vienna, Austria). This platform includes a custom instrument guide with an integrated spiral fiducial pattern as the robot's end-effector, and it uses intra-operative computed tomography (CT) to register the robot to the patient directly before the intervention. The physician can then use a graphical user interface (GUI) to select a path for percutaneous access, and the robot will automatically align the instrument guide along this path. Potential anatomical targets include the liver, kidney, prostate, and spine. This paper describes the robotic platform, workflow, software, and algorithms used by the system. To demonstrate the algorithmic accuracy and suitability of the custom instrument guide, we also present results from experiments as well as estimates of the maximum error between target and instrument tip.

  19. Methods for Estimating Adsorbed Uranium(VI) and Distribution Coefficients of Contaminated Sediments

    USGS Publications Warehouse

    Kohler, M.; Curtis, G.P.; Meece, D.E.; Davis, J.A.

    2004-01-01

    Assessing the quantity of U(VI) that participates in sorption/desorption processes in a contaminated aquifer is an important task when investigating U migration behavior. U-contaminated aquifer sediments were obtained from 16 different locations at a former U mill tailings site at Naturita, CO (U.S.A.) and were extracted with an artificial groundwater, a high pH sodium bicarbonate solution, hydroxylamine hydrochloride solution, and concentrated nitric acid. With an isotopic exchange method, both a KD value for the specific experimental conditions as well as the total exchangeable mass of U(VI) was determined. Except for one sample, KD values determined by isotopic exchange with U-contaminated sediments that were in equilibrium with atmospheric CO2 agreed within a factor of 2 with KD values predicted from a nonelectrostatic surface complexation model (NEM) developed from U(VI) adsorption experiments with uncontaminated sediments. The labile fraction of U(VI) and U extracted by the bicarbonate solution were highly correlated (r2 = 0.997), with a slope of 0.96 ?? 0.01. The proximity of the slope to one suggests that both methods likely access the same reservoir of U(VI) associated with the sediments. The results indicate that the bicarbonate extraction method is useful for estimating the mass of labile U(VI) in sediments that do not contain U(IV). In-situ KD values calculated from the measured labile U(VI) and the dissolved U(VI) in the Naturita alluvial aquifer agreed within a factor of 3 with in-situ K D values predicted with the NEM and groundwater chemistry at each well.

  20. Comparison of different sets of instruments for laparoendoscopic single-site surgery in a surgical simulator with novices.

    PubMed

    Wang, Dong; Shi, Long-Qing; Wang, Jing-Min; Jiang, Xiao-Hua; Ji, Zhen-Ling

    2016-04-01

    Given the parallel entry of working instruments through a single incision in laparoendoscopic single-site surgery, loss of triangulation in the abdominal cavity and counteracting movements of the instruments are inevitable obstacles. Some specially designed devices have emerged to ameliorate these challenges. Twenty-four novice participants were randomized into four groups using assigned instruments, conventional straight instruments, single-curved instruments, double-curved instruments and articulating instruments, respectively, to perform two basic tasks (peg transferring and pattern cutting) 14 times in a modified simulator. A test of the tasks and a resection of the intestine segment of a rat were performed. The task scores and evaluation of intraoperative skills during the resection of the intestine segment were recorded. The instrument of modified National Aeronautics and Space Administration Task Load Index (NASA-TLX) was completed. The task scores of the groups using single-curved instruments and articulating instruments were better than the other two groups on the simulator tasks, consistent with the evaluation of intraoperative skills during the resection of intestine segment. As the proficiency with the instruments increased, the task scores improved, as demonstrated by the learning curve. The workload measured by the modified NASA-TLX tool demonstrated that the groups using articulating instruments and double-curved instruments had a heavier workload in most of the categories compared with the other two groups. Single-curved and articulating instruments are more effective than conventional straight and double-curved devices, and are favourable in laparoendoscopic single-site surgery for novice learners. © 2013 Royal Australasian College of Surgeons.

  1. A review of health-related workplace productivity loss instruments.

    PubMed

    Lofland, Jennifer H; Pizzi, Laura; Frick, Kevin D

    2004-01-01

    The objective of this review was to identify health-related workplace productivity loss survey instruments, with particular emphasis on those that capture a metric suitable for direct translation into a monetary figure. A literature search using Medline, HealthSTAR, PsycINFO and Econlit databases between 1966 and 2002, and a telephone-administered survey of business leaders and researchers, were conducted to identify health-related workplace productivity measurement survey instruments. This review was conducted from the societal perspective. Each identified instrument was reviewed for the following: (i). reliability; (ii). content validity; (iii). construct validity; (iv). criterion validity; (v). productivity metric(s); (vi). instrument scoring technique; (vii). suitability for direct translation into a monetary figure; (viii). number of items; (ix). mode(s) of administration; and (x). disease state(s) in which it had been tested. Reliability and validity testing have been performed for 8 of the 11 identified surveys. Of the 11 instruments identified, six captured metrics that are suitable for direct translation into a monetary figure. Of those six, one instrument measured absenteeism, while the other five measured both absenteeism and presenteeism. All of the identified instruments except for one were available as paper, self-administered questionnaires and many were available in languages other than English. This review provides a comprehensive overview of the published, peer-reviewed survey instruments available to measure health-related workplace productivity loss. As the field of productivity measurement matures, tools may be developed that will allow researchers to accurately calculate lost productivity costs when performing cost-effectiveness and cost-benefit analyses. Using data captured by these instruments, society and healthcare decision makers will be able to make better informed decisions concerning the value of the medications, disease management and

  2. Natural and man-made hexavalent chromium, Cr(VI), in groundwater near a mapped plume, Hinkley, California—study progress as of May 2017, and a summative-scale approach to estimate background Cr(VI) concentrations

    USGS Publications Warehouse

    Izbicki, John A.; Groover, Krishangi D.

    2018-03-22

    This report describes (1) work done between January 2015 and May 2017 as part of the U.S. Geological Survey (USGS) hexavalent chromium, Cr(VI), background study and (2) the summative-scale approach to be used to estimate the extent of anthropogenic (man-made) Cr(VI) and background Cr(VI) concentrations near the Pacific Gas and Electric Company (PG&E) natural gas compressor station in Hinkley, California. Most of the field work for the study was completed by May 2017. The summative-scale approach and calculation of Cr(VI) background were not well-defined at the time the USGS proposal for the background Cr(VI) study was prepared but have since been refined as a result of data collected as part of this study. The proposed summative scale consists of multiple items, formulated as questions to be answered at each sampled well. Questions that compose the summative scale were developed to address geologic, hydrologic, and geochemical constraints on Cr(VI) within the study area. Each question requires a binary (yes or no) answer. A score of 1 will be assigned for an answer that represents data consistent with anthropogenic Cr(VI); a score of –1 will be assigned for an answer that represents data inconsistent with anthropogenic Cr(VI). The areal extent of anthropogenic Cr(VI) estimated from the summative-scale analyses will be compared with the areal extent of anthropogenic Cr(VI) estimated on the basis of numerical groundwater flow model results, along with particle-tracking analyses. On the basis of these combined results, background Cr(VI) values will be estimated for “Mojave-type” deposits, and other deposits, in different parts of the study area outside the summative-scale mapped extent of anthropogenic Cr(VI).

  3. Prior video game exposure does not enhance robotic surgical performance.

    PubMed

    Harper, Jonathan D; Kaiser, Stefan; Ebrahimi, Kamyar; Lamberton, Gregory R; Hadley, H Roger; Ruckle, Herbert C; Baldwin, D Duane

    2007-10-01

    Prior research has demonstrated that counterintuitive laparoscopic surgical skills are enhanced by experience with video games. A similar relation with robotic surgical skills has not been tested. The purpose of this study was to determine whether prior video-game experience enhances the acquisition of robotic surgical skills. A series of 242 preclinical medical students completed a self-reported video-game questionnaire detailing the frequency, duration, and peak playing time. The 10 students with the highest and lowest video-game exposure completed a follow-up questionnaire further quantifying video game, sports, musical instrument, and craft and hobby exposure. Each subject viewed a training video demonstrating the use of the da Vinci surgical robot in tying knots, followed by 3 minutes of proctored practice time. Subjects then tied knots for 5 minutes while an independent blinded observer recorded the number of knots tied, missed knots, frayed sutures, broken sutures, and mechanical errors. The mean playing time for the 10 game players was 15,136 total hours (range 5,840-30,000 hours). Video-game players tied fewer knots than nonplayers (5.8 v 9.0; P = 0.04). Subjects who had played sports for at least 4 years had fewer mechanical errors (P = 0.04), broke fewer sutures (P = 0.01), and committed fewer total errors (P = 0.01). Similarly, those playing musical instruments longer than 5 years missed fewer knots (P = 0.05). In the extremes of video-game experience tested in this study, game playing was inversely correlated with the ability to learn robotic suturing. This study suggests that advanced surgical skills such as robotic suturing may be learned more quickly by athletes and musicians. Prior extensive video-game exposure had a negative impact on robotic performance.

  4. Mechanism of uranium (VI) removal by two anaerobic bacterial communities.

    PubMed

    Martins, Mónica; Faleiro, Maria Leonor; da Costa, Ana M Rosa; Chaves, Sandra; Tenreiro, Rogério; Matos, António Pedro; Costa, Maria Clara

    2010-12-15

    The mechanism of uranium (VI) removal by two anaerobic bacterial consortia, recovered from an uncontaminated site (consortium A) and other from an uranium mine (consortium U), was investigated. The highest efficiency of U (VI) removal by both consortia (97%) occurred at room temperature and at pH 7.2. Furthermore, it was found that U (VI) removal by consortium A occurred by enzymatic reduction and bioaccumulation, while the enzymatic process was the only mechanism involved in metal removal by consortium U. FTIR analysis suggested that after U (VI) reduction, U (IV) could be bound to carboxyl, phosphate and amide groups of bacterial cells. Phylogenetic analysis of 16S rRNA showed that community A was mainly composed by bacteria closely related to Sporotalea genus and Rhodocyclaceae family, while community U was mainly composed by bacteria related to Clostridium genus and Rhodocyclaceae family. Copyright © 2010 Elsevier B.V. All rights reserved.

  5. Patient-specific instruments: industry's innovation with a surgeon's interest.

    PubMed

    Thienpont, Emmanuel; Bellemans, Johan; Delport, Hendrik; Van Overschelde, Philippe; Stuyts, Bart; Brabants, Karl; Victor, Jan

    2013-10-01

    The aim of this study was (1) to survey the orthopaedic companies about the volume of patient-specific instruments (PSI) used in Europe and worldwide; (2) to survey a group of knee arthroplasty surgeons on their acceptance of PSI and finally; (3) to survey a medico-legal expert on PSI-related issues. Seven orthopaedic implant manufacturers were contacted to obtain their sales figures (in volume) of PSI in Europe and worldwide for the 2011 and 2012 period. During the Open Meeting of the Belgian Knee Society, a survey by a direct voting system was submitted to a selection of knee surgeons. Finally, a number of medico-legal 'PSI-related' questions were submitted to an adult reconstruction surgeon/legal expert. The total volume, for all contacted companies, of PSI in Europe for 2012 was 17,515 total knee arthroplasty (TKA) and 82,556 TKA worldwide. Biomet (Warsaw, USA) was the number one in volume, both in Europe as worldwide with their Signature system. Biomet represented 27 % of the market share in PSI worldwide. Stryker preferred not to reply to the survey because of the FDA class 1 recall on ShapeMatch cutting guides. Eighty per cent of the Belgian knee surgeons expressed a great interest in PSI and especially, for 58 % of them, if it would increase their surgical accuracy. They valued it even more in unicompartmental arthroplasty, and 55 % was ready to use single-use instruments. Surprisingly, 47 % of surgeons thought it was the company's responsibility if something goes wrong with a PSI-assisted case. The medico-legal expert concluded that PSI is a complex process that exposes surgeons to new risks in case of failure and stated that companies should not produce surgical guides without validation of the planning by the surgeon. Patient-specific instruments is of great interest if it can proof to increase the surgical accuracy in knee arthroplasty to the level surgeons are expecting and if in the same time it would make the surgical process more efficient. V.

  6. Biased Brownian motion mechanism for processivity and directionality of single-headed myosin-VI.

    PubMed

    Iwaki, Mitsuhiro; Iwane, Atsuko Hikikoshi; Ikebe, Mitsuo; Yanagida, Toshio

    2008-01-01

    Conventional form to function as a vesicle transporter is not a 'single molecule' but a coordinated 'two molecules'. The coordinated two molecules make it complicated to reveal its mechanism. To overcome the difficulty, we adopted a single-headed myosin-VI as a model protein. Myosin-VI is an intracellular vesicle and organelle transporter that moves along actin filaments in a direction opposite to most other known myosin classes. The myosin-VI was expected to form a dimer to move processively along actin filaments with a hand-over-hand mechanism like other myosin organelle transporters. However, wild-type myosin-VI was demonstrated to be monomer and single-headed, casting doubt on its processivity. Using single molecule techniques, we show that green fluorescent protein (GFP)-fused single-headed myosin-VI does not move processively. However, when coupled to a 200 nm polystyrene bead (comparable to an intracellular vesicle in size) at a ratio of one head per bead, single-headed myosin-VI moves processively with large (40 nm) steps. Furthermore, we found that a single-headed myosin-VI-bead complex moved more processively in a high-viscous solution (40-fold higher than water) similar to cellular environment. Because diffusion of the bead is 60-fold slower than myosin-VI heads alone in water, we propose a model in which the bead acts as a diffusional anchor for the myosin-VI, enhancing the head's rebinding following detachment and supporting processive movement of the bead-monomer complex. This investigation will help us understand how molecular motors utilize Brownian motion in cells.

  7. Surgical tool detection and tracking in retinal microsurgery

    NASA Astrophysics Data System (ADS)

    Alsheakhali, Mohamed; Yigitsoy, Mehmet; Eslami, Abouzar; Navab, Nassir

    2015-03-01

    Visual tracking of surgical instruments is an essential part of eye surgery, and plays an important role for the surgeons as well as it is a key component of robotics assistance during the operation time. The difficulty of detecting and tracking medical instruments in-vivo images comes from its deformable shape, changes in brightness, and the presence of the instrument shadow. This paper introduces a new approach to detect the tip of surgical tool and its width regardless of its head shape and the presence of the shadows or vessels. The approach relies on integrating structural information about the strong edges from the RGB color model, and the tool location-based information from L*a*b color model. The probabilistic Hough transform was applied to get the strongest straight lines in the RGB-images, and based on information from the L* and a*, one of these candidates lines is selected as the edge of the tool shaft. Based on that line, the tool slope, the tool centerline and the tool tip could be detected. The tracking is performed by keeping track of the last detected tool tip and the tool slope, and filtering the Hough lines within a box around the last detected tool tip based on the slope differences. Experimental results demonstrate the high accuracy achieved in term of detecting the tool tip position, the tool joint point position, and the tool centerline. The approach also meets the real time requirements.

  8. C7 pars fracture subadjacent to C7 pedicle screw instrumentation at the caudal end of a posterior cervical instrumentation construct.

    PubMed

    Halim, Andrea; Grauer, Jonathan

    2014-07-01

    We report a case of a C7 pars fracture subadjacent to C7 pedicle screw instrumentation at the caudal end of posterior cervical instrumentation construct. To date, posterior cervical instrumentation has been "off label"; however, the US Food and Drug Administration is considering approving label indication of such instrumentation for this common surgical practice. Complications related to the techniques are reported to be relatively low. We know of no previous reports of pars fractures occurring subadjacent to such instrumentation. A 43-year-old man underwent posterior C5-C7 instrumented fusion. Postoperatively, the patient experienced cervical spine injury after a mechanical fall down stairs. Work-up detected bilateral C7 pars fractures subadjacent to the posterior instrumentation construct. After we treated the pars fracture with distal extension of the posterior fusion to the level of T2, the patient progressed to union and marked improvement of initial clinical symptoms that was maintained 2.5 years after posterior instrumentation. To our knowledge, a C7 pars fracture subadjacent to posterior cervical instrumentation construct has not been reported. We hypothesize that the pars may have been vulnerable to fracture because of excessive bone resection during foraminotomy or decortication. This complication was successfully treated by extending the fusion caudally.

  9. Oxidation of Sulfonamides in Aqueous Solution by UV-TiO2-Fe(VI).

    PubMed

    Ma, Yan; Zhang, Kejia; Li, Cong; Zhang, Tuqiao; Gao, Naiyun

    2015-01-01

    The photocatalytic degradation of sulfonamides in aqueous TiO2 suspension under UV irradiation has been investigated using potassium ferrate as electron acceptors. The results showed that the stability of Fe(VI) is dependent on pH significantly, and the stability reduces obviously in the presence of UV-TiO2. The experiments indicated that Fe(VI) could effectively scavenge the conduction band electrons from the surface of TiO2. The photocatalytic oxidation of sulfonamides with Fe(VI) was found to be much faster than that without Fe(VI). The SD, SM, and SMX concentration was greatly reduced by 89.2%, 83.4%, and 82.0%, respectively, after 10 min with UV-TiO2-Fe(VI), comparing to 65.2%, 66.0%, and 71.9%, respectively, with Fe(VI) only in the dark and 71.3%, 72.7%, and 76.0%, respectively, with UV-TiO2. The pH value of solution significantly influenced the sulfonamides degradation in UV-TiO2-Fe(VI) system. The degradation amount of sulfonamides after 10 min was a maximum at pH 7. The intermediate products of sulfonamides oxidation by UV-TiO2-Fe(VI) were analysed by LC-HESI-MS-MS and the results suggested that a majority of sulfonamides turned into large-molecule products without complete mineralization.

  10. Oxidation of Sulfonamides in Aqueous Solution by UV-TiO2-Fe(VI)

    PubMed Central

    Ma, Yan; Zhang, Kejia; Li, Cong; Zhang, Tuqiao; Gao, Naiyun

    2015-01-01

    The photocatalytic degradation of sulfonamides in aqueous TiO2 suspension under UV irradiation has been investigated using potassium ferrate as electron acceptors. The results showed that the stability of Fe(VI) is dependent on pH significantly, and the stability reduces obviously in the presence of UV-TiO2. The experiments indicated that Fe(VI) could effectively scavenge the conduction band electrons from the surface of TiO2. The photocatalytic oxidation of sulfonamides with Fe(VI) was found to be much faster than that without Fe(VI). The SD, SM, and SMX concentration was greatly reduced by 89.2%, 83.4%, and 82.0%, respectively, after 10 min with UV-TiO2-Fe(VI), comparing to 65.2%, 66.0%, and 71.9%, respectively, with Fe(VI) only in the dark and 71.3%, 72.7%, and 76.0%, respectively, with UV-TiO2. The pH value of solution significantly influenced the sulfonamides degradation in UV-TiO2-Fe(VI) system. The degradation amount of sulfonamides after 10 min was a maximum at pH 7. The intermediate products of sulfonamides oxidation by UV-TiO2-Fe(VI) were analysed by LC-HESI-MS-MS and the results suggested that a majority of sulfonamides turned into large-molecule products without complete mineralization. PMID:26347888

  11. Biological Cr(VI) removal using bio-filters and constructed wetlands.

    PubMed

    Michailides, Michail K; Sultana, Mar-Yam; Tekerlekopoulou, Athanasia G; Akratos, Christos S; Vayenas, Dimitrios V

    2013-01-01

    The bioreduction of hexavalent chromium from aqueous solution was carried out using suspended growth and packed-bed reactors under a draw-fill operating mode, and horizontal subsurface constructed wetlands. Reactors were inoculated with industrial sludge from the Hellenic Aerospace Industry using sugar as substrate. In the suspended growth reactors, the maximum Cr(VI) reduction rate (about 2 mg/L h) was achieved for an initial concentration of 12.85 mg/L, while in the attached growth reactors, a similar reduction rate was achieved even with high initial concentrations (109 mg/L), thus confirming the advantage of these systems. Two horizontal subsurface constructed wetlands (CWs) pilot-scale units were also built and operated. The units contained fine gravel. One unit was planted with common reeds and one was kept unplanted. The mean influent concentrations of Cr(VI) were 5.61 and 5.47 mg/L for the planted and unplanted units, respectively. The performance of the planted CW units was very effective as mean Cr(VI) removal efficiency was 85% and efficiency maximum reached 100%. On the contrary, the unplanted CW achieved very low Cr(VI) removal with a mean value of 26%. Both attached growth reactors and CWs proved efficient and viable means for Cr(VI) reduction.

  12. Phase VI Glove Durability Testing

    NASA Technical Reports Server (NTRS)

    Mitchell, Kathryn

    2011-01-01

    The current state-of-the-art space suit gloves, the Phase VI gloves, have an operational life of 25 -- 8 hour Extravehicular Activities (EVAs) in a dust free, manufactured microgravity EVA environment. Future planetary outpost missions create the need for space suit gloves which can endure up to 90 -- 8 hour traditional EVAs or 576 -- 45 minute suit port-based EVAs in a dirty, uncontrolled planetary environment. Prior to developing improved space suit gloves for use in planetary environments, it is necessary to understand how the current state-of-the-art performs in these environments. The Phase VI glove operational life has traditionally been certified through cycle testing consisting of International Space Station (ISS)-based EVA tasks in a clean environment, and glove durability while performing planetary EVA tasks in a dirty environment has not previously been characterized. Testing was performed in the spring of 2010 by the NASA Johnson Space Center (JSC) Crew and Thermal Systems Division (CTSD) to characterize the durability of the Phase VI Glove and identify areas of the glove design which need improvement to meet the requirements of future NASA missions. Lunar simulant was used in this test to help replicate the dirty lunar environment, and generic planetary surface EVA tasks were performed during testing. A total of 50 manned, pressurized test sessions were completed in the Extravehicular Mobility Unit (EMU) using one pair of Phase VI gloves as the test article. The 50 test sessions were designed to mimic the total amount of pressurized cycling the gloves would experience over a 6 month planetary outpost mission. The gloves were inspected periodically throughout testing, to assess their condition at various stages in the test and to monitor the gloves for failures. Additionally, motion capture and force data were collected during 18 of the 50 test sessions to assess the accuracy of the cycle model predictions used in testing and to feed into the

  13. Video-assisted thoracic surgical procedures in children.

    PubMed

    Decampli, William M.

    1998-01-01

    The general principles and current applications of pediatric video-assisted cardiothoracic surgery (PVACTS) are reviewed. The purpose of PVACTS is to improve surgical quality and precision in selected operations. In the 1990s PVACTS has expanded to include the management of a variety of pulmonary, mediastinal, and cardiac lesions. Currently, PVACTS is carried out using a video camera connected to a low-profile scope and a specialized set of surgical instruments. PVACTS is an accepted modality for the diagnosis (by biopsy) of pleuropulmonary and mediastinal disease, and the treatment of pediatric empyema, spontaneous pneumothorax, and mediastinal cysts. Diaphragmatic plication, repair of chylous leak, and ligation of collateral vessels have all been done using PVACTS. PVACTS patent ductus arteriosus (PDA) ligation and vascular ring repair are being successfully carried out in several institutions. The technique at The Children's Hospital of Philadelphia is described. Indications and techniques for PVACTS lobectomy and pneumonectomy are less well established. Suggested anecdotal methods are described. Cardioscopy carries the hope of improving intracardiac repair, and has been applied to several lesions. The future of PVACTS depends on the surgeon's willingness to master it, industry's willingness to customize instruments for pediatric use, and developments in the fields of virtual imaging and augmented reality. Copyright 1998 by W.B. Saunders Company

  14. The far lateral transpontomedullary sulcus approach to pontine cavernous malformations: technical report and surgical results.

    PubMed

    Abla, Adib A; Benet, Arnau; Lawton, Michael T

    2014-09-01

    Pontine cavernous malformations (CMs) located on a peripheral pontine surface or the fourth ventricular floor are resectable lesions, but those deep within the pons away from a pial surface are typically observed. However, the anterior bulge of the pons formed by the brachium pontis creates a unique entry point for access to deep pontine lesions from below, working upward through the pontomedullary sulcus. We developed a transpontomedullary sulcus (TPMS) approach to these lesions. The TPMS approach used the far lateral craniotomy and upper vagoaccessory triangle to define the surgical corridor. The entry point was above the olive, lateral to the pyramidal tracts and cranial nerve (CN) VI, above the preolivary sulcus and CN XII, and medial to CNs VII and VIII and CNs IX through XI. Four patients underwent this approach. All presented with hemorrhage and CN VI palsies. All pontine CMs were resected completely. Three patients were improved or unchanged, with good outcomes (modified Rankin Scale score ≤2) in all patients. The central pons remains difficult territory to access, and new surgical corridors are needed. The bulging underbelly of the pons allows access to pontine lesions deep to the pial surface from below. The far lateral TPMS approach is a novel and more direct alternative to the retrosigmoid transmiddle cerebellar peduncle approach. Unlike the retrosigmoid approach, the TPMS approach requires minimal parenchymal transgression and uses a brainstem entry point medial to most lower CNs. Favorable results demonstrate the feasibility of resecting pontine CMs that might have been previously deemed unresectable.

  15. Virtual reality in surgical education.

    PubMed

    Ota, D; Loftin, B; Saito, T; Lea, R; Keller, J

    1995-03-01

    Virtual reality (VR) is an emerging technology that can teach surgeons new procedures and can determine their level of competence before they operate on patients. Also VR allows the trainee to return to the same procedure or task several times later as a refresher course. Laparoscopic surgery is a new operative technique which requires the surgeon to observe the operation on a video-monitor and requires the acquisition of new skills. VR simulation could duplicate the operative field and thereby enhance training and reduce the need for expensive animal training models. Our preliminary experience has shown that we have the technology to model tissues and laparoscopic instruments and to develop in real time a VR learning environment for surgeons. Another basic need is to measure competence. Surgical training is an apprenticeship requiring close supervision and 5-7 years of training. Technical competence is judged by the mentor and has always been subjective. If VR surgical simulators are to play an important role in the future, quantitative measurement of competence would have to be part of the system. Because surgical competence is "vague" and is characterized by such terms as "too long, too short" or "too close, too far," it is possible that the principles of fuzzy logic could be used to measure competence in a VR surgical simulator. Because a surgical procedure consists of a series of tasks and each task is a series of steps, we will plan to create two important tasks in a VR simulator and validate their use. These tasks consist of laparoscopic knot tying and laparoscopic suturing. Our hypothesis is that VR in combination with fuzzy logic can educate surgeons and determine when they are competent to perform these procedures on patients.

  16. Trends in the Surgical Correction of Gynecomastia.

    PubMed

    Brown, Rodger H; Chang, Daniel K; Siy, Richard; Friedman, Jeffrey

    2015-05-01

    Gynecomastia refers to the enlargement of the male breast due to a proliferation of ductal, stromal, and/or fatty tissue. Although it is a common condition affecting up to 65% of men, not all cases require surgical intervention. Contemporary surgical techniques in the treatment of gynecomastia have become increasingly less invasive with the advent of liposuction and its variants, including power-assisted and ultrasound-assisted liposuction. These techniques, however, have been largely limited in their inability to address significant skin excess and ptosis. For mild to moderate gynecomastia, newer techniques using arthroscopic morcellation and endoscopic techniques promise to address the fibrous component, while minimizing scar burden by utilizing liposuction incisions. Nevertheless, direct excision through periareolar incisions remains a mainstay in treatment algorithms for its simplicity and avoidance of additional instrumentation. This is particularly true for more severe cases of gynecomastia requiring skin resection. In the most severe cases with significant skin redundancy and ptosis, breast amputation with free nipple grafting remains an effective option. Surgical treatment should be individualized to each patient, combining techniques to provide adequate resection and optimize aesthetic results.

  17. Chlorine decay and trihalomethane formation following ferrate(VI) preoxidation and chlorination of drinking water.

    PubMed

    Li, Cong; Luo, Feng; Dong, Feilong; Zhao, Jingguo; Zhang, Tuqiao; He, Guilin; Cizmas, Leslie; Sharma, Virender K

    2017-11-01

    This paper presents the effect of preoxidation with ferrate(VI) (Fe VI O 4 2- , Fe(VI)) prior to chlorination on chlorine decay and formation of disinfection by-products in filtered raw water from a full-scale drinking water treatment plant. The rate of chlorine decay became significantly faster as the concentration of ferrate(VI) increased. Chlorine degradation followed two first-order decay reactions with rate constants k 1 and k 2 for fast and slow decay, respectively. Kinetic modeling established the relationships between k 1 and k 2 and varying dosages of chlorine and ferrate(VI). When ferrate(VI) was used as a pre-oxidant, the levels of trihalomethanes (trichloromethane (TCM), dichlorobromomethane (DCBM), dibromochloromethane (DBCM), and tribromomethane (TBM)) in water samples decreased as the ferrate(VI) concentration increased. The concentrations of these trihalomethanes followed the order TCM > DCBM ≈ DBCM > TBM. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Polyaniline (PANI) modified bentonite by plasma technique for U(VI) removal from aqueous solution

    NASA Astrophysics Data System (ADS)

    Liu, Xinghao; Cheng, Cheng; Xiao, Chengjian; Shao, Dadong; Xu, Zimu; Wang, Jiaquan; Hu, Shuheng; Li, Xiaolong; Wang, Weijuan

    2017-07-01

    Polyaniline (PANI) modified bentonite (PANI/bentonie) was synthesized by plasma induced polymerization of aniline on bentonite surface, and applied to uptake of uranium(VI) ions from aqueous solution. The as-synthesized PANI/bentonie was characterized by scanning electron microscopy (SEM), powder X-ray diffraction (XRD), thermal gravimetric analysis (TGA), and X-ray photoelectron spectroscopy (XPS). Batch adsorption technique was utilized to investigate the adsorption of U(VI) on bentonite and PANI/bentonite. The adsorption of U(VI) (10 mg/L) on PANI/bentonite surface is fairly depend on solution pH, ionic strength, and temperature in solution. The modified PANI on PANI/bentonite surface significantly enhances its adsorption capability for U(VI). The presence of humic acid (HA) can sound enhance U(VI) adsorption on PANI/bentonite at pH < 6.5 because of the strong complexation, and inhibits U(VI) adsorption at pH > 6.5. According to the thermodynamic parameters, the adsorption of U(VI) on PANI/bentonite surface is a spontaneous and endothermic process. The results highlight the application of PANI/bentonite composites as candidate material for the uptake of trace U(VI) from aqueous solution.

  19. 23 CFR 200.11 - Procedures for processing Title VI reviews.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 23 Highways 1 2010-04-01 2010-04-01 false Procedures for processing Title VI reviews. 200.11 Section 200.11 Highways FEDERAL HIGHWAY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION CIVIL RIGHTS TITLE VI PROGRAM AND RELATED STATUTES-IMPLEMENTATION AND REVIEW PROCEDURES § 200.11 Procedures for processing Title...

  20. 23 CFR 200.11 - Procedures for processing Title VI reviews.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 23 Highways 1 2014-04-01 2014-04-01 false Procedures for processing Title VI reviews. 200.11 Section 200.11 Highways FEDERAL HIGHWAY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION CIVIL RIGHTS TITLE VI PROGRAM AND RELATED STATUTES-IMPLEMENTATION AND REVIEW PROCEDURES § 200.11 Procedures for processing Title...

  1. 23 CFR 200.11 - Procedures for processing Title VI reviews.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 23 Highways 1 2011-04-01 2011-04-01 false Procedures for processing Title VI reviews. 200.11 Section 200.11 Highways FEDERAL HIGHWAY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION CIVIL RIGHTS TITLE VI PROGRAM AND RELATED STATUTES-IMPLEMENTATION AND REVIEW PROCEDURES § 200.11 Procedures for processing Title...

  2. 23 CFR 200.11 - Procedures for processing Title VI reviews.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 23 Highways 1 2013-04-01 2013-04-01 false Procedures for processing Title VI reviews. 200.11 Section 200.11 Highways FEDERAL HIGHWAY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION CIVIL RIGHTS TITLE VI PROGRAM AND RELATED STATUTES-IMPLEMENTATION AND REVIEW PROCEDURES § 200.11 Procedures for processing Title...

  3. Thermodynamic Insight into the Solvation and Complexation Behavior of U(VI) in Ionic Liquid: Binding of CMPO with U(VI) Studied by Optical Spectroscopy and Calorimetry.

    PubMed

    Wu, Qi; Sun, Taoxiang; Meng, Xianghai; Chen, Jing; Xu, Chao

    2017-03-06

    The complexation of U(VI) with octylphenyl-N,N-diisobutylcarbamoylmethylphosphine oxide (CMPO, denoted as L) in ionic liquid (IL) C 4 mimNTf 2 was investigated by UV-vis absorption spectrophotometry and isothermal titration calorimetry. Spectro-photometric titration suggests that three successive complexes, UO 2 L j 2+ (j = 1-3), formed both in "dry" (water content < 250 ppm) and "wet" (water content ≈ 12 500 ppm) ionic liquid. However, the thermodynamic parameters are distinctly different in the two ILs. In dry IL, the complexation strength between CMPO and U(VI) is much stronger, with stability constants of the respective complexes more than 1 order of magnitude higher than that in wet IL. Energetically, the complexation of U(VI) with CMPO in dry IL is mainly driven by negative enthalpies. In contrast, the complexation in wet IL is overwhelmingly driven by highly positive entropies as a result of the release of a large amount of water molecules from the solvation sphere of U(VI). Moreover, comparisons between the fitted absorption spectra of complexes in wet IL and that of extractive samples from solvent extraction have identified the speciation involved in the extraction of U(VI) by CMPO in ionic liquid. The results from this study not only offer a thermodynamic insight into the complexation behavior of U(VI) with CMPO in IL but also provide valuable information for understanding the extraction behavior in the corresponding solvent extraction system.

  4. Kinetics and Products of Chromium(VI) Reduction by Iron(II/III)-Bearing Clay Minerals.

    PubMed

    Joe-Wong, Claresta; Brown, Gordon E; Maher, Kate

    2017-09-05

    Hexavalent chromium is a water-soluble pollutant, the mobility of which can be controlled by reduction of Cr(VI) to less soluble, environmentally benign Cr(III). Iron(II/III)-bearing clay minerals are widespread potential reductants of Cr(VI), but the kinetics and pathways of Cr(VI) reduction by such clay minerals are poorly understood. We reacted aqueous Cr(VI) with two abiotically reduced clay minerals: an Fe-poor montmorillonite and an Fe-rich nontronite. The effects of ionic strength, pH, total Fe content, and the fraction of reduced structural Fe(II) [Fe(II)/Fe(total)] were examined. The last variable had the largest effect on Cr(VI) reduction kinetics: for both clay minerals, the rate constant of Cr(VI) reduction varies by more than 3 orders of magnitude with Fe(II)/Fe(total) and is described by a linear free energy relationship. Under all conditions examined, Cr and Fe K-edge X-ray absorption near-edge structure spectra show that the main Cr-bearing product is a Cr(III)-hydroxide and that Fe remains in the clay structure after reacting with Cr(VI). This study helps to quantify our understanding of the kinetics of Cr(VI) reduction by Fe(II/III)-bearing clay minerals and may improve predictions of Cr(VI) behavior in subsurface environments.

  5. Study on Cr(VI) Leaching from Cement and Cement Composites

    PubMed Central

    Palascakova, Lenka; Kanuchova, Maria

    2018-01-01

    This paper reports an experimental study on hexavalent chromium leaching from cement samples and cement composites containing silica fume and zeolite additions that were subjected to various leaching agents. The water-soluble Cr(VI) concentrations in cements ranged from 0.2 to 3.2 mg/kg and represented only 1.8% of the total chromium content. The presence of chromium compounds with both chromium oxidation states of III and VI was detected in the cement samples by X-ray photoelectron spectroscopy (XPS). Leaching tests were performed in a Britton-Robinson buffer to simulate natural conditions and showed increased dissolution of Cr(VI) up to 6 mg/kg. The highest amount of leached hexavalent chromium was detected after leaching in HCl. The findings revealed that the leaching of chromium from cements was higher by 55–80% than that from the cement composites. A minimum concentration was observed for all cement samples when studying the relationship between the soluble Cr(VI) and the cement storage time. PMID:29690550

  6. Study on Cr(VI) Leaching from Cement and Cement Composites.

    PubMed

    Estokova, Adriana; Palascakova, Lenka; Kanuchova, Maria

    2018-04-22

    This paper reports an experimental study on hexavalent chromium leaching from cement samples and cement composites containing silica fume and zeolite additions that were subjected to various leaching agents. The water-soluble Cr(VI) concentrations in cements ranged from 0.2 to 3.2 mg/kg and represented only 1.8% of the total chromium content. The presence of chromium compounds with both chromium oxidation states of III and VI was detected in the cement samples by X-ray photoelectron spectroscopy (XPS). Leaching tests were performed in a Britton-Robinson buffer to simulate natural conditions and showed increased dissolution of Cr(VI) up to 6 mg/kg. The highest amount of leached hexavalent chromium was detected after leaching in HCl. The findings revealed that the leaching of chromium from cements was higher by 55⁻80% than that from the cement composites. A minimum concentration was observed for all cement samples when studying the relationship between the soluble Cr(VI) and the cement storage time.

  7. A critical review of ferrate(VI)-based remediation of soil and groundwater.

    PubMed

    Rai, Prabhat Kumar; Lee, Jechan; Kailasa, Suresh Kumar; Kwon, Eilhann E; Tsang, Yiu Fai; Ok, Yong Sik; Kim, Ki-Hyun

    2018-01-01

    Over the past few decades, diverse chemicals and materials such as mono- and bimetallic nanoparticles, metal oxides, and zeolites have been used for soil and groundwater remediation. Ferrate (Fe VI O 4 2- ) has been widely employed due to its high-valent iron (VI) oxo compound with high oxidation/reduction potentials. Ferrate has received attention for wide environmental applications including water purification and sewage sludge treatment. Ferrate provides great potential for diverse environmental applications without any environmental problems. Therefore, this paper provides comprehensive information on the recent progress on the use of (Fe VI O 4 2- ) as a green material for use in sustainable treatment processes, especially for soil and water remediation. We reviewed diverse synthesis recipes for ferrates (Fe VI O 4 2- ) and their associated physicochemical properties as oxidants, coagulants, and disinfectants for the elimination of a diverse range of chemical and biological species from water/wastewater samples. A summary of the eco-sustainable performance of ferrate(VI) in water remediation is also provided and the future of ferrate(VI) is discussed in this review. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. Probing chromium(III) from chromium(VI) in cells by a fluorescent sensor

    NASA Astrophysics Data System (ADS)

    Hu, Xiangquan; Chai, Jie; Liu, Yanfei; Liu, Bin; Yang, Binsheng

    2016-01-01

    Cellular uptake of Cr(VI), followed by its reduction to Cr(III) with the formation of kinetically inert Cr(III) complexes, is a complex process. To better understand its physiological and pathological functions, efficient methods for the monitoring of Cr(VI) are desired. In this paper a selective fluorescent probe L, rhodamine hydrazide bearing a benzo[b]furan-2-carboxaldehyde group, was demonstrated as a red chemosensor for Cr(III) at about 586 nm. This probe has been used to probe Cr(III) which is reduced from Cr(VI) by reductants such as glutathione (GSH), vitamin C, cysteine (Cys), H2O2 and Dithiothreitol (DTT) by fluorescence spectra. Cr(VI) metabolism in vivo is primarily driven by Vc and GSH. Vc could reduce CrO42 - to Cr(III) in a faster rate than GSH. The indirectly detection limit for Cr(VI) by L + GSH system was determined to be 0.06 μM at pH = 6.2. Moreover, the confocal microscopy image experiments indicated that Cr(VI) can be reduced to Cr(III) inside cells rapidly and the resulted Cr(III) can be captured and imaged timely by L.

  9. VI-14, a novel flavonoid derivative, inhibits migration and invasion of human breast cancer cells