Sample records for surgically implanted radio

  1. Technique for implanting radio transmitters subcutaneously in day-old ducklings

    USGS Publications Warehouse

    Korschgen, C.E.; Kenow, K.P.; Green, W.L.; Samuel, M.D.; Sileo, L.

    1996-01-01

    We developed and evaluated a surgical procedure for implanting radio transmitters in 1-d-old Canvasback (Aythya valisineria) ducklings. Transmitters (1.5 g) were implanted subcutaneously on the back of ducklings while under a general anesthetic, isoflurane, within a few hours of hatching. Evaluations indicate that the procedure is a reliable method for radio-marking ducklings.

  2. Effects of surgically and gastrically implanted radio transmitters on growth and feeding behavior of juvenile chinook salmon

    USGS Publications Warehouse

    Adams, N.S.; Rondorf, D.W.; Evans, S.D.; Kelly, J.E.

    1997-01-01

    We examined the effects of surgically and gastrically implanted radio transmitters (representing 2.3-5.5% of body weight) on the growth and feeding behavior of 192 juvenile chinook salmon Oncorhynchus tshawytscha (114-159 mm in fork length). Throughout the 54-d study, the 48 fish with transmitters in their stomachs (gastric fish) consistently grew more slowly than fish with surgically implanted transmitters (surgery fish), fish with surgery but no implanted transmitter (sham-surgery fish), or fish exposed only to handling (control fish). Growth rates of surgery fish were also slightly impaired at day 21, but by day 54 they were growing at rates comparable with those of control fish. Despite differences in growth, overall health was similar among all test fish. However, movement of the transmitter antenna caused abrasions at the corner of the mouth in all gastric fish, whereas only 22% of the surgery fish had inflammation around the antenna exit wound. Feeding activity was similar among groups, but gastric fish exhibited a coughing behavior and appeared to have difficulty retaining swallowed food. Because growth and feeding behavior were less affected by the presence of surgically implanted transmitters than by gastric implants, we recommend surgically implanting transmitters for biotelemetry studies of juvenile chinook salmon between 114 and 159 mm fork length.

  3. Snake mortality associated with late season radio-transmitter implantation

    Treesearch

    D. Craig Rudolph; Shirley J. Burgdorf; Richard R. Schaefer; Richard N. Conner; Robert T. Zappalorth

    1998-01-01

    Radio-telemetry is an increasingly used procedure to obtain data on the biology of free-living snakes (Reinert 1992, 1994). In Texas and Louisiana we have been using the surgical technique of Weatherhead and Anderka (1984) to implant transmitters in timber rattlesnakes (Crotalus horridus) and Louisiana pine snakes (Pituophis melanoleucus...

  4. Comparison of migration rate and survival between radio-tagged and PIT-tagged migrant yearling chinook salmon in the Snake and Columbia rivers

    USGS Publications Warehouse

    Hockersmith, E.E.; Muir, W.D.; Smith, S.G.; Sandford, B.P.; Perry, R.W.; Adams, N.S.; Rondorf, D.W.

    2003-01-01

    A study was conducted to compare the travel times, detection probabilities, and survival of migrant hatchery-reared yearling chinook salmon Oncorhynchus tshawytscha tagged with either gastrically or surgically implanted sham radio tags (with an imbedded passive integrated transponder [PIT] tag) with those of their cohorts tagged only with PIT tags in the Snake and Columbia rivers. Juvenile chinook salmon with gastrically implanted radio tags migrated significantly faster than either surgically radio-tagged or PIT-tagged fish, while migration rates were similar among surgically radio-tagged and PIT-tagged fish. The probabilities of PIT tag detection at downstream dams varied by less than 5% and were not significantly different among the three groups. Survival was similar among treatments for median travel times of less than approximately 6 d (migration distance of 106 km). However, for both gastrically and surgically radio-tagged fish, survival was significantly less than for PIT-tagged fish, for which median travel times exceeded approximately 10 d (migration distance of 225 km). The results of this study support the use of radio tags to estimate the survival of juvenile chinook salmon having a median fork length of approximately 150 mm (range, 127-285 mm) and a median travel time of migration of less than approximately 6 d.

  5. Effects of implanted radio transmitters with percutaneous antennas on the behavior of Canada Geese

    USGS Publications Warehouse

    Hupp, Jerry W.; Ruhl, G.A.; Pearce, John M.; Mulcahy, Daniel M.; Tomeo, M.A.

    2003-01-01

    We examined whether surgically-implanted radio transmitters with percutaneous antennas affected behavior of Lesser Canada Geese (Branta canadensis parvipes) in Anchorage, Alaska. We implanted either a 26-g VHF radio transmitter or a larger VHF radio that was the same mass (35 g) and shape as a satellite transmitter in the coelom of adult females captured during molt in 2000. A control group of females was marked with leg bands. We simultaneously observed behavior of radio-marked and control females from 4-62 d following capture. We observed no differences in the proportion of time birds in different treatments allocated among grazing, resting, comfort, walking, and alert behavior. Females in different treatments spent a similar proportion of time in the water. Implantation of radio transmitters did not affect the frequency of agonistic interactions. We conclude that coelomic radio transmitters with percutaneous antennas had minimal effects on the behavior of Canada Geese.

  6. Implanting radio transmitters in wintering canvasbacks

    USGS Publications Warehouse

    Olsen, Glenn H.; Dein, F. Joshua; Haramis, G. Michael; Jorde, Dennis G.

    1992-01-01

    To conduct telemetry studies of wintering canvasbacks (Aythya valisineria) on Chesapeake Bay [Maryland, USA], we needed to devise a suitable method of radio transmitter attachment. We describe as aseptic, intraabdominal surgical technique, using the inhalation anesthetic isoflurane, to implant 20-g radio transmitters in free-ranging canvasbacks. We evaluated the technique over 3 winters (1987-89), when an annual average of 83 female canvasbacks received implant surgery during a 9-day period in mid-December. Of 253 ducks, 248 (98%) were implanted successfully, and 200 (80.65) completed the 70-day study until early March. No mortality or abnormal behavior from surgery was identified post-release.

  7. Assessment of gaseous CO2 and AQUI-S as anesthetics when surgically implanting radio transmitters into cutthroat trout

    USGS Publications Warehouse

    Sanderson, T.B.; Hubert, W.A.

    2007-01-01

    Tricaine methanesulfonate (MS-222) and CO2 are anesthetics that can be legally used in fisheries work in the United States, but they are limited in their field applications. A mandatory 21-d withdrawal period is required for fish exposed to MS-222. Carbon dioxide is not approved by the U.S. Food and Drug Administration, but it is a "low regulatory priority drug" that can be used legally for fish anesthesia. However, stressful induction and lengthy recovery times have been associated with CO2. AQUI-S is a clove oil derivative that has the potential to become an approved anesthetic without the limitations of MS-222 or CO2. We compared the efficacy of CO2 with that of AQUI-S when surgically implanting radio transmitters into cutthroat trout Oncorhynchus clarkii. A 20% survival rate was observed when CO2 was used in combination with silk sutures, but a 100% survival rate was observed when CO2 was used in combination with surgical staples to shorten the duration of the surgical procedure. A 100% survival rate was observed when AQUI-S was used in combination with either silk sutures or surgical staples. Carbon dioxide in combination with surgical staples seemed to provide a reasonable option when surgically implanting radio transmitters into cutthroat trout, but AQUI-S may be the preferred anesthesia because high pH and dissolved oxygen levels and low free-CO2 concentrations are maintained during surgical procedures.

  8. Surgical Tooth Implants, Combat and Field.

    DTIC Science & Technology

    1984-07-15

    and identify by block number) --- This Annual Report summarizes progress to date on a long-term implant study of a serrated ceramic dental implant...upper two parts of the implant, post and core and crown, are conventional metaT materials. A series of graded dental implants have been produced to...throughout the experimental period. Periodic radio- graphic analyses of dental implants verify this observation. Gross and microscopic patho- logic analyses

  9. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brown, Richard S.; Carlson, Thomas J.; Welch, Abigail E.

    A multifactor study was conducted by Battelle for the US Army Corps of Engineers to assess the significance of the presence of a radio telemetry transmitter on the effects of rapid decompression from simulated hydro turbine passage on depth acclimated juvenile run-of-the-river Chinook salmon. Study factors were: (1) juvenile chinook salmon age;, subyearling or yearling, (2) radio transmitter present or absent, (3) three transmitter implantation factors: gastric, surgical, and no transmitter, and (4) four acclimation depth factors: 1, 10, 20, and 40 foot submergence equivalent absolute pressure, for a total of 48 unique treatments. Exposed fish were examined for changesmore » in behavior, presence or absence of barotrauma injuries, and immediate or delayed mortality. Logistic models were used to test hypotheses that addressed study objectives. The presence of a radio transmitter was found to significantly increase the risk of barotrauma injury and mortality at exposure to rapid decompression. Gastric implantation was found to present a higher risk than surgical implantation. Fish were exposed within 48 hours of transmitter implantation so surgical incisions were not completely healed. The difference in results obtained for gastric and surgical implantation methods may be the result of study design and the results may have been different if tested fish had completely healed surgical wounds. However, the test did simulate the typical surgical-release time frame for in-river telemetry studies of fish survival so the results are probably representative for fish passing through a turbine shortly following release into the river. The finding of a significant difference in response to rapid decompression between fish bearing radio transmitters and those not implies a bias may exist in estimates of turbine passage survival obtained using radio telemetry. However, the rapid decompression (simulated turbine passage) conditions used for the study represented near worst case exposure for fish passing through turbines. At this time, insufficient data exist about the distribution of river-run fish entering turbines, and particularly, the distribution of fish passing through turbine runners, to extrapolate study findings to the population of fish passing through FCRPS turbines. This study is the first study examining rapid decompression study to include acclimation depth as an experimental factor for physostomous fish. We found that fish acclimated to deeper depth were significantly more vulnerable to barotrauma injury and death. Insufficient information about the distribution of fish entering turbines and their depth acclimation currently exists to extrapolate these findings to the population of fish passing through turbines. However, the risk of barotrauma for turbine-passed fish could be particularly high for subyearling Chinook salmon that migrate downstream at deeper depths late in the early summer portion of the outmigration. Barotrauma injuries led to immediate mortality delayed mortality and potential mortality due to increased susceptibility to predation resulting from loss of equilibrium or swim bladder rupture.« less

  10. Nonlethal gill biopsy does not affect juvenile chinook salmon implanted with radio transmitters

    USGS Publications Warehouse

    Martinelli-Liedtke, T. L.; Shively, R.S.; Holmberg, G.S.; Sheer, M.B.; Schrock, R.M.

    1999-01-01

    Using gastric and surgical transmitter implantation, we compared radio-tagged juvenile chinook salmon Oncorhynchus tshawytscha (T(O)) with tagged fish also having a gill biopsy (T(B)) to determine biopsy effects on fish implanted with radio transmitters. We found no evidence during the 21-d period to suggest that a gill biopsy reduced survival, growth, or gross condition of the tagged-biopsy group, regardless of transmitter implantation technique. We recorded 100% survival of all treatment groups. Relative growth rates of T(O) and T(B) fish did not differ significantly. Leukocrit and lysozyme levels were not significantly different among groups, suggesting that no signs of infection were present. Our findings suggest that small chinook salmon can tolerate the combination of transmitter implantation and gill biopsy without compromising condition relative to fish receiving only the transmitter. We believe a gill biopsy can be used in field telemetry studies, especially when physiological data are needed in addition to behavioral data.

  11. Effect of relative volume on radio transmitter expulsion in subadult common carp

    USGS Publications Warehouse

    Penne, C.R.; Ahrens, N.L.; Summerfelt, R.C.; Pierce, C.L.

    2007-01-01

    Expulsion of surgically implanted radio transmitters is a problem in some fish telemetry studies. We conducted a 109-d experiment to test the hypothesis that variation in relative volume of transmitters surgically implanted in subadult common carp Cyprinus carpio would affect transmitter expulsion. We also necropsied fish at the end of the experiment to evaluate histological evidence for the mechanism of expulsion. Survival rate was high during our experiment; all control fish and 88% of the fish subjected to the implantation surgery survived. Expulsion rate was low; of the 23 fish that received transmitters and survived the experiment, only two (9%) expelled the transmitters. One of these expulsions occurred through a rupture of the incision and the other occurred via the intestine. Retained transmitters were all encapsulated by tissue, and most exhibited multiple adhesions to the intestine, gonads, and body wall. Adhesions were more numerous in fish that received larger transmitters. ?? Copyright by the American Fisheries Society 2007.

  12. Reliability of computer designed surgical guides in six implant rehabilitations with two years follow-up.

    PubMed

    Giordano, Mauro; Ausiello, Pietro; Martorelli, Massimo; Sorrentino, Roberto

    2012-09-01

    To evaluate the reliability and accuracy of computer-designed surgical guides in osseointegrated oral implant rehabilitation. Six implant rehabilitations, with a total of 17 implants, were completed with computer-designed surgical guides, performed with the master model developed by muco-compressive and muco-static impressions. In the first case, the surgical guide had exclusively mucosal support, in the second case exclusively dental support. For all six cases computer-aided surgical planning was performed by virtual analyses with 3D models obtained by dental scan DICOM data. The accuracy and stability of implant osseointegration over two years post surgery was then evaluated with clinical and radiographic examinations. Radiographic examination, performed with digital acquisitions (RVG - Radio Video graph) and parallel techniques, allowed two-dimensional feedback with a margin of linear error of 10%. Implant osseointegration was recorded for all the examined rehabilitations. During the clinical and radiographic post-surgical assessments, over the following two years, the peri-implant bone level was found to be stable and without appearance of any complications. The margin of error recorded between pre-operative positions assigned by virtual analysis and the post-surgical digital radiographic observations was as low as 0.2mm. Computer-guided implant surgery can be very effective in oral rehabilitations, providing an opportunity for the surgeon: (a) to avoid the necessity of muco-periosteal detachments and then (b) to perform minimally invasive interventions, whenever appropriate, with a flapless approach. Copyright © 2012 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  13. Comparing movement patterns of satellite-tagged male and female polar bears

    USGS Publications Warehouse

    Amstrup, Steven C.; Durner, George M.; McDonald, T.L.; Mulcahy, D.M.; Garner, G.W.

    2001-01-01

    Satellite radiotelemetry has provided great insights into the movements and behaviors of polar bears (Ursus maritimus). The diameter of the neck of adult male polar bears exceeds that of their head, however, and radio collars slip off. This has limited collection of movement information to that from radio-collared females. To overcome this difficulty and gather information about their movements, we surgically implanted satellite radio transmitters into 7 male polar bears during 1996 and 1997. We compared movements of implanted males with those of 104 adult females radio-collared between 1985 and 1995. Transmitters were implanted under the skin on the midline of the top of the neck and were equipped with percutaneous antennae. Implanted transmitters operated for up to 161 days providing 3217 satellite relocations. While transmitting, radios implanted in males provided a larger proportion of the highest quality category of position fixes than was obtained from radio-collared females. However, all implanted radios ceased transmitting before reaching their projected life-span. The abrupt termination of transmission from implanted radios suggested mechanical rather than electronic failure. Mean rates of short-term movement for males (1.18 km/h) were lower than for solitary females, females with cubs, and females with yearlings (1.70, 1.84, and 1.95 km/h, respectively). Net geographic movements from the beginning to the end of each month were comparable for males (mean = 135 km) and females (mean = 114, 152, and 168 km). Mean azimuths of these net movements also appeared to be similar. Monthly activity-area sizes for males (mean = 8541 km2) were comparable to those for females (mean = 3698, 9397, and 10 585 km2) during the time period of comparison. In contrast to the other movement measures, males traveled longer mean distances (387 km) each month than did females (217, 289, and 302 km). Movements of males, it appears, were more directed than those of females, but males confined their travels to similar-sized areas.

  14. Imaging technique for the complete edentulous patient treated conventionally or with mini implant overdenture

    PubMed Central

    Meleşcanu Imre, M; Preoteasa, E; Țâncu, AM; Preoteasa, CT

    2013-01-01

    Rationale. The imaging methods are more and more used in the clinical process of modern dentistry. Once the implant based treatment alternatives are nowadays seen as being the standard of care in edentulous patients, these techniques must be integrated in the complete denture treatment. Aim. The study presents some evaluation techniques for the edentulous patient treated by conventional dentures or mini dental implants (mini SKY Bredent) overdentures, using the profile teleradiography. These offer data useful for an optimal positioning of the artificial teeth and the mini dental implants, favoring to obtain an esthetic and functional treatment outcome. We proposed also a method to conceive a simple surgical guide that allows the prosthetically driven implants placement. Material and method. Clinical case reports were made, highlighting the importance of cephalometric evaluation on lateral teleradiographs in complete edentulous patients. A clinical case that gradually reports the surgical guide preparation (Bredent silicon radio opaque), in order to place the mini dental implants in the best prosthetic and anatomic conditions, was presented. Conclusions. The profile teleradiograph is a useful tool for the practitioner. It allows establishing the optimal site for implant placement, in a good relation with the overdenture. The conventional denture can be easily and relatively costless transformed in a surgical guide used during implant placement. PMID:23599828

  15. Surgical and immediate postrelease mortality of harlequin ducks (Histrionicus histrionicus) implanted with abdominal radio transmitters with percutaneous antennae

    USGS Publications Warehouse

    Mulcahy, Daniel M.; Esler, Daniel N.

    1999-01-01

    Radiotelemetry is an essential tool in the study of free-ranging bird populations, and a variety of transmitter-attachment methods have been developed. A promising new method is abdominal implantation of a transmitter with a percutaneous antenna. Researchers using this technique should be concerned about and aware of mortality during surgery and during the immediate postrelease period (the 14-day period following surgery). Of 307 radio-implant surgeries performed between 1995 and 1997 in harlequin ducks (Histrionicus histrionicus), 7 (2.3%) deaths were documented during surgery or anesthetic recovery. Of 295 birds released with implanted radios, 10 (3.4%) died during the immediate postrelease period. Modifications to anesthetic procedures used in the 204 surgeries performed in 1996 and 1997 reduced mortality to 1.5% during surgery and 1.5% during the immediate postrelease period. Anesthetic modifications included intubation of all birds, placement of birds on an elevated platform that allowed the head to rest at a level lower than the body during surgery, placement of a heated water blanket under the birds during surgery, monitoring of body temperature, and use of electrocardiogram and Doppler ultrasound to monitor heart rates and arrhythmias. Low levels of mortality associated with abdominal implantation of radio transmitters may be unavoidable, but mortality can be minimized with adjustments to anesthetic technique.

  16. Successful implantation of an abdominal aortic blood pressure transducer and radio-telemetry transmitter in guinea pigs - Anaesthesia, analgesic management and surgical methods, and their influence on hemodynamic parameters and body temperature.

    PubMed

    Schmitz, Sabrina; Henke, Julia; Tacke, Sabine; Guth, Brian

    2016-01-01

    Guinea pigs (GPs) are a valuable cardiovascular pharmacology model. Implantation of a radio-telemetry system into GPs is, however, challenging and has been associated with a high failure rate in the past. We provide information on a novel procedure for implanting telemetry devices into GPs and we have measured the hemodynamics (arterial blood pressure, BP and heart rate, HR) and core body temperature (BT) in the 24h after surgery. Male Hartley GPs (Crl:HA, 350-400g, 6.5weeks, n=16) were implanted with a radio transmitter abdominally and were then monitored continuously (HR, BP and BT) for 24h after surgery. 13 of 16 GPs (81%) survived the surgery. Surgery duration was 94min (min) (range: 76-112min) and anaesthesia duration was 131min (range: 107-158min). GPs lost body weight until 2days after surgery and then regained weight. Mean arterial BP increased from 33.7mmHg directly after surgery to 59.1mmHg after 24h. HR increased from 206bpm directly after surgery to 286bpm at 8h and fell to 251bpm at 24h after implantation. BT was 36°C directly after surgery, fell to 35.4°C until regaining of the righting reflex and then stabilized at 38.5°C after 24h. A high survival rate in telemetered GPs is possible. We achieved this through a procedure with minimal stress through habituation and planning, continuous warming during anaesthesia, an optimal anaesthetic and analgesic management, efficient surgical techniques and vitamin C supplementation. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.

  17. Testing tail-mounted transmitters with Myocastor coypus (nutria)

    USGS Publications Warehouse

    Merino, S.; Carter, J.; Thibodeaux, G.

    2007-01-01

    We developed a tail-mounted radio-transmitter for Myocastor coypus (nutria) that offers a practical and efficient alternative to collar or implant methods. The mean retention time was 96 d (range 57-147 d, n = 7), making this a practical method for short-term studies. The tail-mounts were less injurious to animals than collars and easier for field researchers to implement than either collars or surgically implanted transmitters.

  18. A subcutaneous channeling probe for implanting long leads

    NASA Technical Reports Server (NTRS)

    Lund, G. F.; Simmonds, R. C.; Williams, B. A.

    1977-01-01

    The channeling probe described in the present paper was designed to overcome surgical problems of the type that were encountered when a multichannel radio transmitter had to be implanted in a cow. The probe was made of a flexible but sufficiently stiff 9.5-mm-diam nylon rod, consisting of 46-cm sections for convenience in sterilization and surgical handling. Stainless steel sleaves reinforced the threaded connecting joints. At one end, arrowhead-shaped channeling heads could be attached to produce wide channels for large sensors. The other end was tapered for narrow channels. Postoperative problems were not encountered in the use of this probe in cows, sheep, and dogs.

  19. Hand-Held Units for Short-Range Wireless Biotelemetry

    NASA Technical Reports Server (NTRS)

    Miranda, Felix A.; Simons, Rainee N.

    2008-01-01

    Special-purpose hand-held radiotransceiver units have been proposed as means of short-range radio powering and interrogation of surgically implanted microelectromechanical sensors and actuators. These units are based partly on the same principles as those of the units described in "Printed Multi- Turn Loop Antennas for RF Biotelemetry" (LEW-17879-1), NASA Tech Briefs, Vol. 31, No. 6 (June 2007), page 48. Like the previously reported units, these units would make it unnecessary to have wire connections between the implanted devices and the external equipment used to activate and interrogate them. Like a unit of the previously reported type, a unit of the type now proposed would include a printed-circuit antenna on a dielectric substrate. The antenna circuitry would include integrated surface-mount inductors for impedance tuning. Circuits for processing the signals transmitted and received by the antenna would be included on the substrate. During operation, the unit would be positioned near (but not in electrical contact with) a human subject, in proximity to a microelectromechanical sensor or actuator that has been surgically implanted in the subject. It has been demonstrated that significant electromagnetic coupling with an implanted device could be established at a distance of as much as 4 in. (.10 cm). During operation in the interrogation mode, the antenna of the unit would receive a radio telemetry signal transmitted by the surgically implanted device. The antenna substrate would have dimensions of approximately 3.25 by 3.75 inches (approximately 8.3 by 9.5 cm). The substrate would have a thickness of the order of 30 mils (of the order of a somewhat less than a millimeter). The substrate would be made of low-radiofrequency- loss dielectric material that could be, for example, fused quartz, alumina, or any of a number of commercially available radio-frequency dielectric composite materials. The antenna conductors would typically be made of copper or a combination of chromium and gold. The choice of metal and the thickness of the metal layer(s) would depend on the choice of substrate material. For example, on a quartz or alumina substrate, one would typically use a layer of chromium 150 A thick and a layer of gold 2 m thick. The proposed units and the implanted devices that they would interrogate or activate would be inherently safe to use. They would operate at low radiated-power levels for short interrogation times (typically, milliseconds). Hence, there would be little local heating of tissues surrounding the implanted devices and little absorption of radio energy by such sensitive body parts as the eyes and the brain. Because the implanted devices would not depend on battery power and would be activated only during short interrogation intervals and would otherwise be in the goff h state most of the time, the useful lifetimes of the implanted devices would be greater than those of comparable battery-powered implanted devices. The compactness of the hand-held transceiver units would facilitate transport and storage and would facilitate self-diagnosis by patients able to handle the units while away from medical facilities.

  20. Automatic patient respiration failure detection system with wireless transmission

    NASA Technical Reports Server (NTRS)

    Dimeff, J.; Pope, J. M.

    1968-01-01

    Automatic respiration failure detection system detects respiration failure in patients with a surgically implanted tracheostomy tube, and actuates an audible and/or visual alarm. The system incorporates a miniature radio transmitter so that the patient is unencumbered by wires yet can be monitored from a remote location.

  1. Growth and physiological responses to surgical and gastric radio transmitter implantation techniques in subyearling chinook salmon (Oncorhynchus tshawytscha)

    USGS Publications Warehouse

    Martinelli, Theresa L.; Hansel, H.C.; Shively, R.S.

    1998-01-01

    We examined the effects of surgical and gastric transmitter implantation techniques on the growth, general physiology and behavior of 230 subyearling chinook salmon (Oncorhynchus tshawytscha, Walbaum) (100 mm-154 mm fork length). The transmitter weighed 1.3 g in air (0.9 g in water) and comprised, on average, 6% of the body weight of the fish (in air). Individuals were randomly assigned to an experimental group (control, surgical or gastric) and a sampling period (day 5 or day 21). Relative growth rate was expressed as% body weight gained/day. General condition was assessed by necropsy. Physiological response variables included hematocrit, leucocrit and plasma protein concentration. The mean relative growth rates of control, surgical and gastric fish were not significantly different at day 5. By day 21, the gastric group had a significantly lower relative growth rate (1.3%) as compared to the surgical group (1.8%) and the control group (1.9%) (P = 0.0001). Mean hematocrit values were significantly lower in the surgical (41.8%) and gastric (42.2%) groups as compared to controls (47.3%) at day 5 (P = 0.01), but all were within normal range for salmonids. No significant differences in hematocrit values were detected at day 21. Leucocrit values for all groups were ??? 1% in 99% of the fish. Both tagged groups had significantly lower mean plasma protein levels as compared to controls at day 5 (P = 0.001) and day 21 (P = 0.0001). At day 21 the gastric group (64.4 g 100 m1-1) had significantly lower mean plasma protein levels than the surgical group (68.8 g 100 ml-1) (P = 0.0001). Necropsies showed decreasing condition of gastrically tagged fish over time, and increasing condition of surgical fish. Paired releases of surgically and gastrically implanted yearling chinook salmon in the lower Columbia River in spring, 1996 revealed few significant differences in migration behavior through two reservoirs. We conclude that gastrically implanted fish show decreased growth and condition over a 21 d period. We recommend a surgical implantation method for long-term studies of juvenile salmonids, however, gastric implantation may be suitable for short-term studies.

  2. The Atlantic Seaduck Project: Medical Aspects

    USGS Publications Warehouse

    Olsen, Glenn H.; Perry, M.C.; Wells, A.M.; Lohnes, E.J.R.; Osenton, P.C.

    2005-01-01

    Some populations of seaducks, especially scoters along the Atlantic Coast, have been declining over recent decades. A joint US-Canadian tearn has been working to capture and surgically implant satellite radio transmitters in these ducks. Black scoters (Melanitta nigra) captured on the Restigouche River in New Brunswick, Canada and surf scoters (M. perspicilata) captured on Chesapeake Bay, Maryland, USA have been tracked by the use of Argos/NOAA polar orbiting operational environmental satellites to their breeding and molting areas and back south to their wintering ranges. Successful capture techniques included night-lighting and a capture net gun. A captive colony of seaducks has been maintained for feeding habits and nutritional studies. Veterinary medicine has played a key role in the surgical implantation of the satellite transmitters and in developing heath procedures for the captive seaduck colony.

  3. Measurement of bovine body and scrotal temperature using implanted temperature sensitive radio transmitters, data loggers and infrared thermography

    NASA Astrophysics Data System (ADS)

    Wallage, A. L.; Gaughan, J. B.; Lisle, A. T.; Beard, L.; Collins, C. W.; Johnston, S. D.

    2017-07-01

    Synchronous and continuous measurement of body (BT) and scrotal temperature (ST) without adverse welfare or behavioural interference is essential for understanding thermoregulation of the bull testis. This study compared three technologies for their efficacy for long-term measurement of the relationship between BT and ST by means of (1) temperature sensitive radio transmitters (RT), (2) data loggers (DL) and (3) infrared imaging (IRI). After an initial pilot study on two bulls to establish a surgical protocol, RTs and DLs were implanted into the flank and mid-scrotum of six Wagyu bulls for between 29 and 49 days. RT frequencies were scanned every 15 min, whilst DLs logged every 30 min. Infrared imaging of the body (flank) and scrotum of each bull was recorded hourly for one 24-h period and compared to RT and DL data. After a series of subsequent heat stress studies, bulls were castrated and testicular tissue samples processed for evidence of histopathology. Radio transmitters were less reliable than DLs; RTs lost >11 % of data, whilst 11 of the 12 DLs had 0 % data loss. IRI was only interpretable in 35.8 % of images recorded. Pearson correlations between DL and RT were strong for both BT ( r > 0.94, P < 0.001) and ST ( r > 0.80, P < 0.001). Surgery produced temporary minor inflammation and scrotal hematoma in two animals post-surgery. Whilst scar tissue was observed at all surgical sutured sites when bulls were castrated, there was no evidence of testicular adhesion and normal active spermatogenesis was observed in six of the eight implanted testicles. There was no significant correlation of IRI with either DL or RT. We conclude that DLs provided to be a reliable continuous source of data for synchronous measurement of BT and ST.

  4. Surgical implantation of temperature-sensitive transmitters and data-loggers to record body temperature in koalas (Phascolarctos cinereus).

    PubMed

    Adam, D; Johnston, S D; Beard, L; Nicholson, V; Lisle, A; Gaughan, J; Larkin, R; Theilemann, P; Mckinnon, A; Ellis, W

    2016-01-01

    Under predicted climate change scenarios, koala distribution in Australia is expected to be adversely affected. Recent studies have attempted to identify suitable habitat, based on models of bioclimatic regions, but to more accurately reflect the thermal tolerance and behavioural adaptations of the various regional populations, the koala's response to periods of heat stress will need to be investigated at the individual animal level. To explore the safety and suitability of temperature-sensitive intra-abdominal implants for monitoring core body temperature in the koala. A temperature-sensitive radio transmitter and thermal iButton data-logger, waxed together as a package, were surgically implanted into the abdominal cavity of four captive koalas. In one animal the implant was tethered and in the other three, it was left free-floating. After 3 months, the implants were removed and all four koalas recovered without complications. The tethering of the package in the one koala resulted in minor inflammation and adhesion, so this practice was subsequently abandoned. The free-floating deployments were complication-free and revealed a diurnal body temperature rhythm, with daily ranges of 0.4-2.8°C. The minimum recorded body temperature was 34.2°C and the maximum was 37.7°C. The difference in the readings obtained from the transmitters and iButtons never exceeded 0.3°C. The suitability of the surgical approach was confirmed, from both the animal welfare and data collection points of view. © 2016 Australian Veterinary Association.

  5. Effects of implanted transmitters on adult bluegills at two temperatures

    USGS Publications Warehouse

    Knights, Brent C.; Lasee, Becky A.

    1996-01-01

    Laterally compressed panfishes are small and have limited intraperitoneal space; thus, they may suffer adversely from surgically implanted transmitters even if the transmitter meets the generally recommended ratio of transmitter weight to fish weight of 2%. We studied the effects of intraperitoneal transmitters (2.81 g) on survival, growth, healing, and health of bluegills Lepomis macrochirus (mean weight 133 g) held for 8 weeks at 6 degree C and 20 degree C. Radio-tagged bluegills at 20 degree C had a mortality rate of 10% and tag loss rate of 15%. At 6 degree C, bluegills had no mortality or tag loss. Radio-tagged and reference fish fed in both 20 degree C raceways; however, a few reference fish appeared dominant at feeding time. This dominance by a few reference fish was also indicated by a large weight gain for three reference fish in each 20 degree C raceway. At 6 degree C, neither reference fish nor radio-tagged fish fed activity. Radio-tagged fish held at 20 degree C exhibited pelvic fin erosion, erythema and necrosis at the antenna exit and at suture insertions, and lost or loose sutures, effects not observed in other test fishes. Examination of fish held at 20 degree C also showed enclosure of the transmitters in a fibrous capsule and adhesion of visceral organs. Epithelialization over the incision occurred in radio-tagged bluegills at both temperatures, but there was little further healing at 6 degree C. At 20 degree C, tissue responses included chronic inflammation and dermal granulation. Radio-tagged fish did not appear to be more susceptible than reference fish to bacterial infection. Mortality, adverse morphological effects, altered behavior, and limited healing in bluegills suggest that implanted transmitters impaired their health. Thus, movement and habitat use data collected by telemetry for this species and perhaps for other panfishes should be interpreted with caution.

  6. Loss from harlequin ducks of abdominally implanted radio transmitters equipped with percutaneous antennas

    USGS Publications Warehouse

    Mulcahy, D.M.; Esler, Daniel N.; Stoskopf, M.K.

    1999-01-01

    We documented extrusion and loss of abdominally implanted radio transmitters with percutaneous antennas from adult female Harlequin Ducks (Histrionicus histrionicus). Birds were captured during wing molt (late August to mid-September) in 1995-1997. Of 44 Harlequin Ducks implanted with radios and recaptured, 7 (16%) had lost their transmitters and 5 (11%) had radios in the process of extruding. Most (11 of 12) extrusions and losses occurred in birds implanted with radios in 1996 and recaptured in 1997. We suggest that transmitter extrusions and losses were due largely to changes in transmitter design made between 1095 and 1996. Transmitters implanted in 1996 were cylindrical rather than spherical, had a flat end with an abrupt edge, and the lower portion of the antenna was reinforced. Radio losses occurred after the 7-mo monitoring period and caused no apparent harm to the birds. Investigators using implanted radios with percutaneous antennas for long-term projects should be aware of the potential for radio extrusion and should minimize the problem by using transmitters that have no sharp edges and that are wide, rather than narrow.

  7. Dual implantation of a radio-telemeter and vascular access port allows repeated hemodynamic and pharmacological measures in conscious lean and obese rats.

    PubMed

    Bussey, C T; Leeuw, A E de; Cook, R F; Ashley, Z; Schofield, J; Lamberts, R R

    2014-07-01

    Expansion of physiological knowledge increasingly requires examination of processes in the normal, conscious state. The current study describes a novel approach combining surgical implantation of radio-telemeters with vascular access ports (VAPs) to allow repeated hemodynamic and pharmacological measures in conscious rats. Dual implantation was conducted on 16-week-old male lean and obese Zucker rats. Continued viability one month after surgery was observed in 67% of lean and 44% of obese animals, giving an overall 54% completion rate. Over the five-week measurement period, reliable and reproducible basal mean arterial pressure and heart rate measures were observed. VAP patency and receptor-independent vascular reactivity were confirmed by consistent hemodynamic responses to sodium nitroprusside (6.25 µg/kg). Acutely, minimal hemodynamic responses to repeated bolus administration of 0.2 mL saline indicated no significant effect of increased blood volume or administration stress, making repeated acute measures viable. Similarly, repeated administration of the β-adrenoceptor agonist dobutamine (30 µg/kg) at 10 min intervals resulted in reproducible hemodynamic changes in both lean and obese animals. Therefore, our study demonstrates that this new approach is viable for the acute and chronic assessment of hemodynamic and pharmacological responses in both lean and obese conscious rats. This technique reduces the demand for animal numbers and allows hemodynamic measures with minimal disruption to animals' welfare, while providing reliable and reproducible results over several weeks. In conclusion, dual implantation of a radio-telemeter and VAP introduces a valuable technique for undertaking comprehensive studies involving repeated pharmacological tests in conscious animals to address important physiological questions. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  8. Behavior of White Sturgeon near hydroprojects and fishways

    USGS Publications Warehouse

    Parsley, M.J.; Wright, C.D.; Van Der Leeuw, B. K.; Kofoot, E.E.; Perry, C.A.; Moser, M.L.

    2006-01-01

    During March 2004 through November 2005, white sturgeon movements were monitored at The Dalles Dam to characterize their distribution and movements in the immediate vicinity of the dam and to determine timing and routes of passage. A combination of radio and acoustic telemetry technologies were used to detect tagged fish within fishways and at strategic locations along the dam, the shorelines, and in the forebay. White sturgeon > 95 cm total length (TL) that were captured on baited setlines fished in the forebay and in the tailrace cul-de-sac received a surgically implanted transmitter that emitted radio and acoustic signals. During the course of this study, a total of 148 fish were tagged; 58 were captured and released in the forebay and 90 in the tailrace.

  9. A standard operating procedure for the surgical implantation of transmitters in juvenile salmonids

    USGS Publications Warehouse

    Liedtke, T.L.; Beeman, J.W.; Gee, L.P.

    2012-01-01

    Biotelemetry is a useful tool to monitor the movements of animals and is widely applied in fisheries research. Radio or acoustic technology can be used, depending on the study design and the environmental conditions in the study area. A broad definition of telemetry also includes the use of Passive Integrated Transponder (PIT) tags, either separately or with a radio or acoustic transmitter. To use telemetry, fish must be equipped with a transmitter. Although there are several attachment procedures available, surgical implantation of transmitters in the abdominal cavity is recognized as the best technique for long-term telemetry studies in general (Stasko and Pincock, 1977; Winter, 1996; Jepsen, 2003), and specifically for juvenile salmonids, Oncorhynchus spp. (Adams and others, 1998a, 1998b; Martinelli and others, 1998; Hall and others, 2009). Studies that use telemetry assume that the processes by which the animals are captured, handled, and tagged, as well as the act of carrying the transmitter, will have minimal effect on their behavior and performance. This assumption, commonly stated as a lack of transmitter effects, must be valid if telemetry studies are to describe accurately the movements and behavior of an entire population of interest, rather than the subset of that population that carries transmitters. This document describes a standard operating procedure (SOP) for surgical implantation of radio or acoustic transmitters in juvenile salmonids. The procedures were developed from a broad base of published information, laboratory experiments, and practical experience in tagging thousands of fish for numerous studies of juvenile salmon movements near Columbia River and Snake River hydroelectric dams. Staff from the Western Fisheries Research Center's Columbia River Research Laboratory (CRRL) frequently have used telemetry studies to evaluate new structures or operations at hydroelectric dams in the Columbia River Basin, and these evaluations typically require large numbers of tagged fish. For example, a study conducted at the dams on the Columbia River and funded by the U.S. Army Corps of Engineers required tagging and monitoring of 40,000 juvenile salmon during a 3-month migration period (Counihan and others, 2006a, 2006b; Perry and others, 2006). To meet the demands of such a large study, the authors and CRRL staff refined the SOP to increase efficiency in the tagging process while maintaining high standards of fish care. The SOP has been used in laboratory and field settings for more than 15 years, and consistently has produced low mortality rates (<1 percent) and transmitter loss rates (<0.01 percent) in the 24-36 hours after tagging. In addition to describing the detailed surgical procedures required for transmitter implantation, this document provides guidance on fish collection, handling and holding, and the release of tagged fish. Although often overlooked, or at least underemphasized, these processes can have a large impact on the outcome of the tagging procedure. Stress associated with the individual steps in handling and tagging can be cumulative and lethal (Maule and others, 1988; Wedemeyer and others, 1990; Portz and others, 2006), so the goal is to provide the best possible fish care at every step in order to manage the overall effect on study fish.

  10. An animal tracking system for behavior analysis using radio frequency identification.

    PubMed

    Catarinucci, Luca; Colella, Riccardo; Mainetti, Luca; Patrono, Luigi; Pieretti, Stefano; Secco, Andrea; Sergi, Ilaria

    2014-09-01

    Evaluating the behavior of mice and rats has substantially contributed to the progress of research in many scientific fields. Researchers commonly observe recorded video of animal behavior and manually record their observations for later analysis, but this approach has several limitations. The authors developed an automated system for tracking and analyzing the behavior of rodents that is based on radio frequency identification (RFID) in an ultra-high-frequency bandwidth. They provide an overview of the system's hardware and software components as well as describe their technique for surgically implanting passive RFID tags in mice. Finally, the authors present the findings of two validation studies to compare the accuracy of the RFID system versus commonly used approaches for evaluating the locomotor activity and object exploration of mice.

  11. A Suprachoroidal Electrical Retinal Stimulator Design for Long-Term Animal Experiments and In Vivo Assessment of Its Feasibility and Biocompatibility in Rabbits

    PubMed Central

    Zhou, J. A.; Woo, S. J.; Park, S. I.; Kim, E. T.; Seo, J. M.; Chung, H.; Kim, S. J.

    2008-01-01

    This article reports on a retinal stimulation system for long-term use in animal electrical stimulation experiments. The presented system consisted of an implantable stimulator which provided continuous electrical stimulation, and an external component which provided preset stimulation patterns and power to the implanted stimulator via a paired radio frequency (RF) coil. A rechargeable internal battery and a parameter memory component were introduced to the implanted retinal stimulator. As a result, the external component was not necessary during the stimulation mode. The inductive coil pair was used to pass the parameter data and to recharge the battery. A switch circuit was used to separate the stimulation mode from the battery recharging mode. The implantable stimulator was implemented with IC chips and the electronics, except for the stimulation electrodes, were hermetically packaged in a biocompatible metal case. A polyimide-based gold electrode array was used. Surgical implantation into rabbits was performed to verify the functionality and safety of this newly designed system. The electrodes were implanted in the suprachoroidal space. Evoked cortical potentials were recorded during electrical stimulation of the retina. Long-term follow-up using OCT showed no chorioretinal abnormality after implantation of the electrodes. PMID:18317521

  12. An introduction to the practical and ethical perspectives on the need to advance and standardize the intracoelomic surgical implantation of electronic tags in fish

    USGS Publications Warehouse

    Brown, R.S.; Eppard, M.B.; Murchie, K.J.; Nielsen, J.L.; Cooke, S.J.

    2011-01-01

    The intracoelomic surgical implantation of electronic tags (including radio and acoustic telemetry transmitters, passive integrated transponders and archival biologgers) is frequently used for conducting studies on fish. Electronic tagging studies provide information on the spatial ecology, behavior and survival of fish in marine and freshwater systems. However, any surgical procedure, particularly one where a laparotomy is performed and the coelomic cavity is opened, has the potential to alter the survival, behavior or condition of the animal which can impair welfare and introduce bias. Given that management, regulatory and conservation decisions are based on the assumption that fish implanted with electronic tags have similar fates and behavior relative to untagged conspecifics, it is critical to ensure that best surgical practices are being used. Also, the current lack of standardized surgical procedures and reporting of specific methodological details precludes cross-study and cross-year analyses which would further progress the field of fisheries science. This compilation of papers seeks to identify the best practices for the entire intracoelomic tagging procedure including pre- and post-operative care, anesthesia, wound closure, and use of antibiotics. Although there is a particular focus on salmonid smolts given the large body of literature available on that group, other life-stages and species of fish are discussed where there is sufficient knowledge. Additional papers explore the role of the veterinarian in fish surgeries, the need for minimal standards in the training of fish surgeons, providing a call for more complete and transparent procedures, and identifying trends in procedures and research needs. Collectively, this body of knowledge should help to improve data quality (including comparability and repeatability), enhance management and conservation strategies, and maintain the welfare status of tagged fish. ?? 2010 Springer Science+Business Media B.V.

  13. Clinical application of stereolithographic surgical guide with a handpiece guidance apparatus: a case report.

    PubMed

    Ozan, Oguz; Seker, Emre; Kurtulmus-Yilmaz, Sevcan; Ersoy, Ahmet Ersan

    2012-10-01

    The success of implant-supported restorations depends on the treatment planning and the transfer of planning through the surgical field. Recently, new computer-aided design and manufacturing (CAD/CAM) techniques, such as stereolithographic (SLA) rapid prototyping, have been developed to fabricate surgical guides to improve the precision of implant placement. The objective of the present case is to introduce a recently developed SLA surgical guide system into the rehabilitation of a 62-year-old male patient with mandibular edentulism. After obtaining a cone-beam computerized tomography (CBCT) scan of the mandible with a radiographic template, the images were transferred into a 3-dimensional (3D) image-based software for implant planning. The StentCad Beyond SLA surgical guide system, which is a combination of a currently used surgical template with pilot hollows and a surgical handpiece guidance apparatus, was designed to transfer a preoperatively defined implant position onto the surgical site without any drill-surgical guide contact. For the fabrication of this system, a surgical handpiece was scanned by a laser optical scanner and a mucosa-supported surgical guide was designed according to the patient's 3D model, which was attained from the CBCT images. Four dental implants were inserted through the SLA surgical guide system by a torque-controlled surgical handpiece to the interforaminal region via a flapless surgical procedure. Implants were assessed 3 months after surgery, and an implant-retained mandibular overdenture was fabricated. The present case emphasizes that CAD/CAM SLA surgical guides, along with CBCT images and scanning data, may help clinicians plan and place dental implants.

  14. Evaluation of intensity of artefacts in CBCT by radio-opacity of composite simulation models of implants in vitro

    PubMed Central

    Kuusisto, N; Vallittu, P K; Lassila, L V J

    2015-01-01

    Objectives: The aim was to compare the intensity of artefacts in CBCT images caused by different percentages of radio-opacifying material in composite simulation models of implants. Titanium and zirconia models of implants were used as a reference for the evaluation of the intensity of artefacts. Methods: Seven different percentages of radio-opacifying BaAlSiO2 fillers were added to composite resin to fabricate seven step wedges and simulation models of implants. Titanium and zirconia simulation models of implants were also fabricated. Aluminium step wedge was used as a reference for the measurement of grey values in intraoral radiographs. Step wedges were exposed with a Planmeca Intra X-ray machine (Planmeca Oy, Helsinki, Finland). All composite, titanium and zirconia simulation models of implants were exposed with a SCANORA® 3D dental X-ray machine (Soredex, Tuusula, Finland). Images and grey values were analysed with ImageJ software (National Institutes of Health, Bethesda, MD). To demonstrate possible artefacts between all the simulation models of implants, the images were also visually compared with each other using ImageJ software. Results: Artefacts were clearly present in CBCT images caused by titanium and zirconia and when the composite material consisted at least 20% BaAlSiO2. The intensity of artefacts increased when the radio-opacity of the composite material increased. Conclusions: Materials containing less radio-opacity produce less pronounced artefacts. The cut-off point for artefacts is at 20% radio-opaque filling material in composite material. PMID:25283364

  15. Reliability of a CAD/CAM Surgical Guide for Implant Placement: An In Vitro Comparison of Surgeons' Experience Levels and Implant Sites.

    PubMed

    Park, Su-Jung; Leesungbok, Richard; Cui, Taixing; Lee, Suk Won; Ahn, Su-Jin

    This in vitro study evaluated the reliability of a surgical guide with regard to different levels of operator surgical experience and implant site. A stereolithographic surgical guide for epoxy resin mandibles with three edentulous molar sites was produced using a computer-aided design/computer-assisted manufacture (CAD/CAM) system. Two surgeons with and two surgeons without implant surgery experience placed implants in a model either using or not using the CAD/CAM surgical guide. Four groups were created: inexperienced surgeon without the guide (group 1); experienced surgeon without the guide (group 2); inexperienced surgeon with the guide (group 3); and experienced surgeon with the guide (group 4). Planned implants and placed implants were superimposed using digital software, and deviation parameters were calculated. There were no significant differences in any of the deviation parameters between the groups when using the surgical guide. With respect to the implant sites, there were no significant differences among the groups in any parameter. Use of the CAD/CAM surgical guide reduced discrepancies among operators performing implant surgery regardless of their level of experience. Whether or not the guide was used, differences in the anterior-posterior implant site in the molar area did not affect the accuracy of implant placement.

  16. Embedded electronics for a 64-channel wireless brain implant

    NASA Astrophysics Data System (ADS)

    Burgert, Johann D.; Malasek, Jan; Martel, Sylvain M.; Wiseman, Colette; Fofonoff, Timothy; Dyer, Robert; Hunter, Ian W.; Hatsopoulos, Nicholas; Donoghue, John

    2001-10-01

    The Telemetric Electrode Array System (TEAS) is a surgically implantable device for the study of neural activity in the brain. An 8x8 array of electrodes collects intra-cortical neural signals and connects them to an analog front end. The front end amplifies and digitizes these microvolt-level signals with 12 bits of resolution and at 31KHz per channel. Peak detection is used to extract the information carrying features of these signals, which are transmitted over a Bluetooth-based radio link at 725 Kbit/sec. The electrode array is made up of 1mm tall, 60-micron square electrodes spaced 500 microns tip-to-tip. A flex circuit connector provides mechanical isolation between the brain and the electronics, which are mounted to the cranium. Power consumption and management is a critical aspect of the design. The entire system must operate off a surgically implantable battery. With this power source, the system must provide the functionality of a wireless, 64-channel oscilloscope for several hours. The system also provides a low-power sleep mode during which the battery can be inductively charged. Power dissipation and biocompatibility issues also affect the design of the electronics for the probe. The electronics system must fit between the skull and the skin of the test subject. Thus, circuit miniaturization and microassembly techniques are essential to construct the probe's electronics.

  17. 78 FR 17940 - Certain Computerized Orthopedic Surgical Devices, Software, Implants, and Components Thereof...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-25

    ..., Software, Implants, and Components Thereof; Notice of Receipt of Complaint; Solicitation of Comments... Certain Computerized Orthopedic Surgical Devices, Software, Implants, and Components Thereof, DN 2945; the... importation of certain computerized orthopedic surgical devices, software, implants, and components thereof...

  18. Bio-medical telemetry: Sensing and transmitting biological information from animals to man

    NASA Technical Reports Server (NTRS)

    Mackay, S.

    1971-01-01

    The application of small radio transmitters for monitoring biological activity in animals and humans is discussed. The microminiaturization of the electronic transmitters makes it possible for them to be swallowed and to operate within the body with no external connections. The small size also makes it possible for the transmitters to be surgically implanted or carried externally to monitor specific bodily functions. The use of satellites to monitor the activity of birds and animals carrying small transmitters is described. Photographs of birds, fish, and reptiles which were equipped with miniature electronic monitors are provided.

  19. Mortality of Mississippi Sandhill Crane chicks

    USGS Publications Warehouse

    Olsen, Glenn H.

    2004-01-01

    Mississippi sandhill cranes (Grus canadensis pulla) are a highly endangered species that live in the wild in 1 county in Mississippi. As part of a large effort to restore these endangered cranes, we are conducting a project to look at the causes of mortality in crane chicks on the Mississippi Sandhill Crane National Wildlife Refuge in Gautier, MS, USA. This includes surgically implanting miniature radio transmitters in crane chicks to gather data on mortality. This article describes some of the practical difficulties in conducting this type of project in a savannah and swamp location along the Gulf Coast of the USA.

  20. Enhancement of matrix metalloproteinases 2 and 9 accompanied with neurogenesis following collagen glycosaminoglycan matrix implantation after surgical brain injury.

    PubMed

    Hsu, Wei-Cherng; Yu, Chun-Hsien; Kung, Woon-Man; Huang, Kuo-Feng

    2018-06-01

    Surgical brain injury may result in irreversible neurological deficits. Our previous report showed that partial regeneration of a traumatic brain lesion is achieved by implantation of collagen glycosaminoglycan (CGM). Matrix metalloproteinases (MMPs) may play an important role in neurogenesis but there is currently a lack of studies displaying the relationship between the stimulation of MMPs and neurogenesis after collagen glycosaminoglycan implantation following surgical brain trauma. The present study was carried out to further examine the expression of MMP2 and MMP9 after implantation of collagen glycosaminoglycan (CGM) following surgical brain trauma. Using the animal model of surgically induced brain lesion, we implanted CGM into the surgical trauma. Rats were thus divided into three groups: (1) sham operation group: craniotomy only; (2) lesion (L) group: craniotomy + surgical trauma lesion; (3) lesion + CGM (L + CGM) group: CGM implanted following craniotomy and surgical trauma lesion. Cells positive for SOX2 (marker of proliferating neural progenitor cells) and matrix metalloproteinases (MMP2 and MMP9) in the lesion boundary zone were assayed and analyzed by immunofluorescence and ELISA commercial kits, respectively. Our results demonstrated that following implantation of CGM after surgical brain trauma, significant increases in MMP2 + /SOX2 + cells and MMP9 + /SOX2 + cells were seen within the lesion boundary zone in the L + CGM group. Tissue protein concentrations of MMP2 and MMP9 also increased after CGM scaffold implantation. These findings suggest that implantation of a CGM scaffold alone after surgical brain trauma can enhance the expression of MMP2 and MMP9 accompanied by neurogenesis.

  1. Titanium modified with layer-by-layer sol-gel tantalum oxide and an organodiphosphonic acid: a coating for hydroxyapatite growth.

    PubMed

    Arnould, C; Volcke, C; Lamarque, C; Thiry, P A; Delhalle, J; Mekhalif, Z

    2009-08-15

    Titanium and its alloys are widely used in surgical implants due to their appropriate properties like corrosion resistance, biocompatibility, and load bearing. Unfortunately when metals are used for orthopedic and dental implants there is the possibility of loosening over a long period of time. Surface modification is a good way to counter this problem. A thin tantalum oxide layer obtained by layer-by-layer (LBL) sol-gel deposition on top of a titanium surface is expected to improve biocorrosion resistance in the body fluid, biocompatibility, and radio-opacity. This elaboration step is followed by a modification of the tantalum oxide surface with an organodiphosphonic acid self-assembled monolayer, capable of chemically binding to the oxide surface, and also improving hydroxyapatite growth. The different steps of this proposed process are characterized by surfaces techniques like contact angle, X-ray photoelectron spectroscopy (XPS), and atomic force microscopy (AFM).

  2. Inflammatory reaction to fabric collars from percutaneous antennas attached to intracoelomic radio transmitters implanted in harlequin ducks (Histrionicus histrionicus)

    USGS Publications Warehouse

    Mulcahy, Daniel M.; Burek, K.A.; Esler, Daniel N.

    2007-01-01

    In wild birds implanted intracoelomically with radio transmitters, a synthetic fabric collar placed around the base of a percutaneous antenna is believed to function as a barrier to contamination of the coelom. We examined 13 fabric collars recovered from percutaneous antennas of radio transmitters implanted intracoelomically in harlequin ducks (Histrionicus histrionicus) 12 months earlier. Both the transmitters and antenna collars were encapsulated in fibrous connective tissue, with adhesions to internal organs. Histologically, bacteria were evident at the fabric-plastic interface in 8 of 10 collars examined in cross section and along the length of the collar in 3 collars examined longitudinally. Bacteria were confined within the fibrotic sheath surrounding the transmitter and the antenna collar in all birds. No evidence of chronic systemic effects secondary to implantation was present on hematologic or serum biochemical testing. These findings indicate that antenna collars do not prevent the entry of bacteria along the percutaneous antenna but may help stabilize the antenna and minimize coelomic contamination. We conclude that radio transmitters implanted into the coelom of harlequin ducks do not appear to cause significant health problems for at least 1 year after implantation.

  3. Expansion of a Predoctoral Surgical Implant Selective for Dental Students.

    PubMed

    Seitz, Stefanie D; Zimmermann, Richard L; Hendricson, William D

    2016-03-01

    Historically, predoctoral dental education programs have focused on the restoration of implants in the clinical environment; however, given the increase in dental implant therapy being performed by general dentists, the need to incorporate surgical implant training is becoming evident. This article describes a predoctoral surgical implant selective at the University of Texas Health Science Center at San Antonio and its evolution across five years to include emerging techniques and technology to enhance students' understanding of dental implant therapy, both surgical and restorative. From virtual implant planning and guided surgery to intra-oral scanning of implants for custom abutments and restorations, students obtained first-hand experiences with a wide spectrum of aspects of implant therapy. The results of anonymous surveys completed by 2014-15 students before and after the year-long selective regarding their impression of the program are also discussed.

  4. Impact of imaging landmark on the risk of MRI-related heating near implanted medical devices like cardiac pacemaker leads.

    PubMed

    Nordbeck, Peter; Ritter, Oliver; Weiss, Ingo; Warmuth, Marcus; Gensler, Daniel; Burkard, Natalie; Herold, Volker; Jakob, Peter M; Ertl, Georg; Ladd, Mark E; Quick, Harald H; Bauer, Wolfgang R

    2011-01-01

    Implanted medical devices such as cardiac pacemakers pose a potential hazard in magnetic resonance imaging. Electromagnetic fields have been shown to cause severe radio frequency-induced tissue heating in some cases. Imaging exclusion zones have been proposed as an instrument to reduce patient risk. The purpose of this study was to further assess the impact of the imaging landmark on the risk for unintended implant heating by measuring the radio frequency-induced electric fields in a body phantom under several imaging conditions at 1.5T. The results show that global radio frequency-induced coupling is highest with the torso centered along the superior-inferior direction of the transmit coil. The induced E-fields inside the body shift when changing body positioning, reducing both global and local radio frequency coupling if body and/or conductive implant are moved out from the transmit coil center along the z-direction. Adequate selection of magnetic resonance imaging landmark can significantly reduce potential hazards in patients with implanted medical devices. © 2010 Wiley-Liss, Inc.

  5. Reliability of implant placement after virtual planning of implant positions using cone beam CT data and surgical (guide) templates.

    PubMed

    Nickenig, Hans-Joachim; Eitner, Stephan

    2007-01-01

    We assessed the reliability of implant placement after virtual planning of implant positions using cone-beam CT data and surgical guide templates. A total of 102 patients (250 implants, 55.4% mandibular; mean patient age, 40.4 years) who had undergone implant treatment therapy in an armed forces dental clinic (Cologne, Germany) between July 1, 2005 and December 1, 2005. They were treated with a system that allows transfer of virtual planning to surgical guide templates. Only in eight cases the surgical guides were not used because a delayed implant placement was necessary. In four posterior mandibular cases, handling was limited because of reduced interocclusal distance, requiring 50% shortening of the drill guides. The predictability of implant size was high: only one implant was changed to a smaller diameter (because of insufficient bone). In all cases, critical anatomical structures were protected and no complications were detected in postoperative panoramic radiographs. In 58.1% (147) of the 250 implants, a flapless surgery plan was realized. Implant placement after virtual planning of implant positions using cone beam CT data and surgical templates can be reliable for preoperative assessment of implant size, position, and anatomical complications. It is also indicative of cases amenable to flapless surgery.

  6. Surgical insertions of transmitters and telemetry methods in fisheries research

    USGS Publications Warehouse

    Wargo Rub, A. Michelle; Jepsen, Niels; Liedtke, Theresa L.; Moser, L; Weber III, E. P. Scott

    2015-01-01

    Use of electronic transmitter and monitoring systems to track movements of aquatic animals has increased continuously since the inception of these systems in the mid-1950s. The purpose of the present report is to provide information about veterinary principles and their incorporation into surgical implantation procedures for fish. We also intend to provide insight into the unique challenges of field-based aquatic surgical studies. Within this context, 4 aspects of the process for surgical implantation of transmitters in fish (ie, handling, aseptic technique, anesthesia, and implantation) will be described. Effects of surgical insertion of transmitters (ie, tagging) and aspects of the surgical implantation process where collaboration and professional exchanges among nonveterinarian researchers and veterinarians may be most fruitful will be discussed. Although this report focuses on surgical implantation, the principles and protocols described here (other than incision and suture placement) are also applicable to studies that involve injection of transmitters into fish.

  7. 47 CFR 95.1209 - Permissible communications.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... PERSONAL RADIO SERVICES Medical Device Radiocommunication Service (MedRadio) § 95.1209 Permissible..., diagnostic and therapeutic information associated with a medical implant device or medical body-worn device... that is not included with a medical implant or medical body-worn device. Wireless retransmission of...

  8. Does the Implant Surgical Technique Affect the Primary and/or Secondary Stability of Dental Implants? A Systematic Review

    PubMed Central

    Shadid, Rola Muhammed; Sadaqah, Nasrin Rushdi; Othman, Sahar Abdo

    2014-01-01

    Background. A number of surgical techniques for implant site preparation have been advocated to enhance the implant of primary and secondary stability. However, there is insufficient scientific evidence to support the association between the surgical technique and implant stability. Purpose. This review aimed to investigate the influence of different surgical techniques including the undersized drilling, the osteotome, the piezosurgery, the flapless procedure, and the bone stimulation by low-level laser therapy on the primary and/or secondary stability of dental implants. Materials and methods. A search of PubMed, Cochrane Library, and grey literature was performed. The inclusion criteria comprised observational clinical studies and randomized controlled trials (RCTs) conducted in patients who received dental implants for rehabilitation, studies that evaluated the association between the surgical technique and the implant primary and/or secondary stability. The articles selected were carefully read and classified as low, moderate, and high methodological quality and data of interest were tabulated. Results. Eight clinical studies were included then they were classified as moderate or high methodological quality and control of bias. Conclusions. There is a weak evidence suggesting that any of previously mentioned surgical techniques could influence the primary and/or secondary implant stability. PMID:25126094

  9. Optimization in multi-implant placement for immediate loading in edentulous arches using a modified surgical template and prototyping: a case report.

    PubMed

    Jayme, Sérgio J; Muglia, Valdir A; de Oliveira, Rafael R; Novaes, Arthur B Júnior

    2008-01-01

    Immediate loading of dental implants shortens the treatment time and makes it possible to give the patient an esthetic appearance throughout the treatment period. Placement of dental implants requires precise planning that accounts for anatomic limitations and restorative goals. Diagnosis can be made with the assistance of computerized tomographic scanning, but transfer of planning to the surgical field is limited. Recently, novel CAD/CAM techniques such as stereolithographic rapid prototyping have been developed to build surgical guides in an attempt to improve precision of implant placement. The aim of this case report was to show a modified surgical template used throughout implant placement as an alternative to a conventional surgical guide.

  10. Reliability of implant surgical guides based on soft-tissue models.

    PubMed

    Maney, Pooja; Simmons, David E; Palaiologou, Archontia; Kee, Edwin

    2012-12-01

    The purpose of this study was to determine the accuracy of implant surgical guides fabricated on diagnostic casts. Guides were fabricated with radiopaque rods representing implant positions. Cone beam computerized tomograms were taken with guides in place. Accuracy was evaluated using software to simulate implant placement. Twenty-two sites (47%) were considered accurate (13 of 24 maxillary and 9 of 23 mandibular sites). Soft-tissue models do not always provide sufficient accuracy for fabricating implant surgical guides.

  11. Evaluation of primary and secondary stability of titanium implants using different surgical techniques.

    PubMed

    Tabassum, Afsheen; Meijer, Gert J; Walboomers, X Frank; Jansen, John A

    2014-04-01

    To investigate the influence of different surgical techniques on the primary and secondary implant stability using trabecular bone of goats as an implantation model. In the iliac crest of eight goats, 48 cylindrical-screw-type implants with a diameter of 4.2 mm (Dyna(®) ; Bergen op Zoom, the Netherlands) were installed, using three different surgical techniques: (i) 5% undersized, using a final drill diameter of 4 mm; (ii) 15% undersized, using a final drill diameter of 3.6 mm; and (iii) 25% undersized, using a final drill diameter of 3.2 mm. Peak insertion torque values were measured by a Digital(®) (MARK-10 Corporation, New York, NY, USA) torque gauge instrument during placement. At 3 weeks after implantation, removal torque was measured. Histomorphometrically, the peri-implant bone volume was measured in three zones; the inner zone (0-500 μm), the middle zone (500-1000 μm) and the outer zone (1000-1500 μm). Evaluation of the obtained data demonstrated no statistically significant difference between different surgical techniques regarding removal torque values. With respect to the percentage peri-implant bone volume (%BV), also no significant difference could be observed between all three applied surgical techniques for both the inner, middle and outer zone. However, irrespective of the surgical technique, it was noticed that the %BV was significantly higher for the inner zone as compared to middle and outer zone (P < 0.05) around the implant. At 3 weeks after implant installation, independent of the used undersized surgical technique, the %BV in the inner zone (0-500 μm) peri-implant area was improved due to both condensation of the surrounding bone as also the translocation of host bone particles along the implant surface. Surprisingly, no mechanical beneficial effect of the 25% undersized surgical technique could be observed as compared to the 5% or 15% undersized surgical technique to improve primary or secondary implant stability. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  12. Assessment of MRI issues at 3-Tesla for metallic surgical implants: findings applied to 61 additional skin closure staples and vessel ligation clips.

    PubMed

    Gill, Amreeta; Shellock, Frank G

    2012-01-09

    Metallic skin closure staples and vessel ligation clips should be tested at 3-Tesla to characterize MRI issues in order to ensure patient safety. Therefore, metallic surgical implants were assessed at 3-Tesla for magnetic field interactions, MRI-related heating, and artifacts. A skin closure staple (Visistat Skin Stapler, staple, Polytetrafluoroethylene, PTFE, coated 316L/316LVM stainless steel; Teleflex Medical, Durham, NC) and a vessel ligation clip (Hemoclip Traditional, stainless steel; Teleflex Medical, Durham, NC) that represented the largest metallic sizes made from materials with the highest magnetic susceptibilities (i.e., based on material information) among 61 other surgical implants (52 metallic implants, 9 nonmetallic implants) underwent evaluation for magnetic field interactions, MRI-related heating, and artifacts using standardized techniques. MRI-related heating was assessed by placing each implant in a gelled-saline-filled phantom with MRI performed using a transmit/receive RF body coil at an MR system reported, whole body averaged SAR of 2.9-W/kg for 15-min. Artifacts were characterized using T1-weighted, SE and GRE pulse sequences. Each surgical implant showed minor magnetic field interactions (20- and 27-degrees, which is acceptable from a safety consideration). Heating was not substantial (highest temperature change, ≤ 1.6°C). Artifacts may create issues if the area of interest is in the same area or close to the respective surgical implant. The results demonstrated that it would be acceptable for patients with these metallic surgical implants to undergo MRI at 3-Tesla or less. Because of the materials and dimensions of the surgical implants that underwent testing, these findings pertain to 61 additional similar implants.

  13. Assessment of MRI issues at 3-Tesla for metallic surgical implants: findings applied to 61 additional skin closure staples and vessel ligation clips

    PubMed Central

    2012-01-01

    Purpose Metallic skin closure staples and vessel ligation clips should be tested at 3-Tesla to characterize MRI issues in order to ensure patient safety. Therefore, metallic surgical implants were assessed at 3-Tesla for magnetic field interactions, MRI-related heating, and artifacts. Methods A skin closure staple (Visistat Skin Stapler, staple, Polytetrafluoroethylene, PTFE, coated 316L/316LVM stainless steel; Teleflex Medical, Durham, NC) and a vessel ligation clip (Hemoclip Traditional, stainless steel; Teleflex Medical, Durham, NC) that represented the largest metallic sizes made from materials with the highest magnetic susceptibilities (i.e., based on material information) among 61 other surgical implants (52 metallic implants, 9 nonmetallic implants) underwent evaluation for magnetic field interactions, MRI-related heating, and artifacts using standardized techniques. MRI-related heating was assessed by placing each implant in a gelled-saline-filled phantom with MRI performed using a transmit/receive RF body coil at an MR system reported, whole body averaged SAR of 2.9-W/kg for 15-min. Artifacts were characterized using T1-weighted, SE and GRE pulse sequences. Results Each surgical implant showed minor magnetic field interactions (20- and 27-degrees, which is acceptable from a safety consideration). Heating was not substantial (highest temperature change, ≤ 1.6°C). Artifacts may create issues if the area of interest is in the same area or close to the respective surgical implant. Conclusions The results demonstrated that it would be acceptable for patients with these metallic surgical implants to undergo MRI at 3-Tesla or less. Because of the materials and dimensions of the surgical implants that underwent testing, these findings pertain to 61 additional similar implants. PMID:22230200

  14. Reliability of implant placement with stereolithographic surgical guides generated from computed tomography: clinical data from 94 implants.

    PubMed

    Ersoy, Ahmet Ersan; Turkyilmaz, Ilser; Ozan, Oguz; McGlumphy, Edwin A

    2008-08-01

    Dental implant placement requires precise planning with regard to anatomic limitations and restorative goals. The aim of this study was to evaluate the match between the positions and axes of the planned and placed implants using stereolithographic (SLA) surgical guides. Ninety-four implants were placed using SLA surgical guides generated from computed tomography (CT) between 2005 and 2006. Radiographic templates were used for all subjects during CT imaging. After obtaining three-dimensional CT images, each implant was virtually placed on the CT images. SLA surgical guides, fabricated using an SLA machine with a laser beam to polymerize the liquid photo-polymerized resin, were used during implant placement. A new CT scan was taken for each subject following implant placement. Special software was used to fuse the images of the planned and placed implants, and the locations and axes were compared. Compared to the planned implants, the placed implants showed angular deviation of 4.9 degrees+/-2.36 degrees, whereas the mean linear deviation was 1.22+/-0.85 mm at the implant neck and 1.51+/-1 mm at the implant apex. Compared to the implant planning, the angular deviation and linear deviation at the neck and apex of the placed maxillary implants were 5.31 degrees+/-0.36 degrees, 1.04+/-0.56 mm, and 1.57+/-0.97 mm, respectively, whereas corresponding figures for placed mandibular implants were 4.44 degrees+/-0.31 degrees, 1.42+/-1.05 mm, and 1.44+/-1.03 mm, respectively. SLA surgical guides using CT data may be reliable in implant placement and make flapless implant placement possible.

  15. Carmustine wafer implantation for high-grade gliomas: Evidence-based safety efficacy and practical recommendations from the Neuro-oncology Club of the French Society of Neurosurgery.

    PubMed

    Roux, A; Caire, F; Guyotat, J; Menei, P; Metellus, P; Pallud, J

    2017-12-01

    There is a growing body of evidence that carmustine wafer implantation during surgery is an effective therapeutic adjunct to the standard combined radio-chemotherapy regimen using temozolomide in newly diagnosed and recurrent high-grade glioma patient management with a statistically significant survival benefit demonstrated across several randomized clinical trials, as well as prospective and retrospective studies (grade A recommendation). Compelling clinical data also support the safety of carmustine wafer implantation (grade A recommendation) in these patients and suggest that observed adverse events can be avoided in experienced neurosurgeon hands. Furthermore, carmustine wafer implantation does not seem to impact negatively on the quality of life and the completion of adjuvant oncological treatments (grade C recommendation). Moreover, emerging findings support the potential of high-grade gliomas molecular status, especially the O(6)-Methylguanine-DNA Methyltransferase promoter methylation status, in predicting the efficacy of such a surgical strategy, especially at recurrence (grade B recommendation). Finally, carmustine wafer implantation appears to be cost-effective in high-grade glioma patients when performed by an experienced team and when total or subtotal resection can be achieved. Altogether, these data underline the current need for a new randomized clinical trial to assess the impact of a maximal safe resection with carmustine wafer implantation followed by the standard combined chemoradiation protocol stratified by molecular status in high-grade glioma patients. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  16. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brown, Richard S.; Eppard, M. B.; Murchie, Karen J.

    The intracoelomic surgical implantation of electronic tags (including radio and acoustic telemetry transmitters, passive integrated transponders and archival biologgers) is frequently used for conducting studies on fish. Electronic tagging studies provide information on the spatial ecology, behavior and survival of fish in marine and freshwater systems. However, any surgical procedure, particularly one where a laparotomy is performed and the coelomic cavity is opened, has the potential to alter the survival, behavior or condition of the animal which can impair welfare and introduce bias. Given that management, regulatory and conservation decisions are based on the assumption that fish implanted with electronicmore » tags have similar fates and behavior relative to untagged conspecifics, it is critical to ensure that best surgical practices are being used. Also, the current lack of standardized surgical procedures and reporting of specific methodological details precludes cross-study and cross-year analyses which would further progress the field of fisheries science. This compilation of papers seeks to identify the best practices for the entire intracoelomic tagging procedure including pre- and post-operative care, anesthesia, wound closure, and use of antibiotics. Although there is a particular focus on salmonid smolts given the large body of literature available on that group, other life-stages and species of fish are discussed where there is sufficient knowledge. Additional papers explore the role of the veterinarian in fish surgeries, the need for minimal standards in the training of fish surgeons, providing a call for more complete and transparent procedures, and identifying trends in procedures and research needs. Collectively, this body of knowledge should help to improve data quality (including comparability and repeatability), enhance management and conservation strategies, and maintain the welfare status of tagged fish.« less

  17. Reconstruction of a Severely Atrophied Alveolar Ridge by Computer-Aided Gingival Simulation and 3D-Printed Surgical Guide: A Case Report.

    PubMed

    Song, In-Seok; Lee, Mi-Ran; Ryu, Jae-Jun; Lee, Ui-Lyong

    Dental implants positioned in severely atrophied anterior maxillae require esthetic or functional compromises. This case report describes the rehabilitation of a severely atrophied alveolar ridge with a three-dimensional (3D) computer-aided design/computer-aided manufacture (CAD/CAM) surgical guide. A 50-year-old woman had a severely atrophied anterior maxilla with unfavorably positioned dental implants. Functional and esthetic prosthodontic restoration was difficult to achieve. An anterior segmental osteotomy was planned to reposition the dental implants. A 3D surgical guide was designed for precise relocation of the segment. The surgical guide firmly grasped the impression copings of the dental implants, minimizing surgical errors. Three-dimensional gingival simulation was used preoperatively to estimate the appropriate position of the gingiva. Rigid fixation to the surrounding bone allowed immobilization of the implant-bone segment. Satisfactory esthetic and functional outcomes were attained 6 months after surgery. Finally, a severely atrophied alveolar ridge with unfavorably positioned dental implants was recovered with minimal esthetic and functional deterioration using gingival simulation and a 3D CAD/CAM surgical guide.

  18. Survival of captive and free-ranging Harlequin Ducks (Histrionicus histrionicus) following surgical liver biopsy

    USGS Publications Warehouse

    Mulcahy, Daniel M.; Esler, Daniel N.

    2010-01-01

    We measured intra- and postoperative mortality rates of captive and free-ranging Harlequin Ducks (Histrionicus histrionicus) undergoing surgical liver biopsy sampling for determination of the induction of cytochrome P4501A, a biomarker of oil exposure. Liver biopsies were taken from and radio transmitters were implanted into 157 free-ranging Harlequin Ducks over three winters (55 in 2000, 55 in 2001, and 47 in 2002). No birds died during surgery, but seven (4.5%) died during recovery from anesthesia (three in 2001 and four in 2002). None of the deaths could be attributed directly to the liver biopsy. Four of the 150 (2.7%) birds that were released died in the 2 wk period after surgery. All post-release deaths occurred in 2001; no birds died after release in 2000 or 2002. No mortalities of 36 captive birds occurred during surgery or recovery or in the 2 wk period following surgery. Hemorrhage was a minor problem with one captive bird. Surgical liver biopsies appear to be a safe procedure, but anesthetic complications may occur with overwintering ducks.

  19. [The use of synthetic mesh implants in surgical treatment of pelvic organ prolapse].

    PubMed

    Pastorčáková, M; Huser, M; Belkov, A I; Ventruba, P

    2014-04-01

    Pelvic organ prolapse (POP) surgical treatment went through major changes thanks to availability and wider expansion of mesh implants (MI). This work is focused on critical analysis of outcomes of these surgical procedures and recommendation prescription for their uses in application pelvic surgery. There was made analysis of published outcomes and experience with MI use in POP surgical treatment. OUTCOMES were analysed separately for each pelvic bottom section. Main criteria were surgical complications and treatment effectivity based on objective measurable parameters and subjective patients evaluation. There are formalized suitable indications and conditions for individual pelvic bottom sections for safe MI use in reconstructive POP surgery. On the basis of objective data authors also define specific situations when MI use doesn't bring any benefit and it is not recommended. Mesh implants have their definite place in POP surgical treatment. Implants with right indication and right surgical technique in comparison with classic surgical procedures have significantly lower recurrence risk with comparable or higher surgical complication rate.

  20. [Retrieval and failure analysis of surgical implants in Brazil: the need for proper regulation].

    PubMed

    Azevedo, Cesar R de Farias; Hippert, Eduardo

    2002-01-01

    This paper summarizes several cases of metallurgical failure analysis of surgical implants conducted at the Laboratory of Failure Analysis, Instituto de Pesquisas Tecnológicas (IPT), in Brazil. Failures with two stainless steel femoral compression plates, one stainless steel femoral nail plate, one Ti-6Al-4V alloy maxillary reconstruction plate, and five Nitinol wires were investigated. The results showed that the implants were not in accordance with ISO standards and presented evidence of corrosion-assisted fracture. Furthermore, some of the implants presented manufacturing/processing defects which also contributed to their premature failure. Implantation of materials that are not biocompatible may cause several types of adverse effects in the human body and lead to premature implant failure. A review of prevailing health legislation is needed in Brazil, along with the adoption of regulatory mechanisms to assure the quality of surgical implants on the market, providing for compulsory procedures in the reporting and investigation of surgical implants which have failed in service.

  1. The effect of the local use of chlorhexidine in surgical treatment of experimental peri-implantitis in dogs.

    PubMed

    Carcuac, Olivier; Abrahamsson, Ingemar; Charalampakis, Georgios; Berglundh, Tord

    2015-02-01

    To evaluate the effect of surgical treatment of experimental peri-implantitis at implants with different surface characteristics using different anti-infective procedures. Four implants with different surface characteristics (A: TiOblast, B: OsseoSpeed, C: AT-I, D: TiUnite) were installed in a randomized order in each side of the mandible in 6 labrador dogs 3 months after tooth extraction. Experimental peri-implantitis was induced 3 months later. Surgical treatment of peri-implantitis was performed. The implants were cleaned with gauze soaked in either saline (control) or chlorhexidine (test). Clinical and radiographical examinations were performed and microbiological samples were taken during a 6-month period after surgery. Biopsies were obtained and prepared for histological analysis. Clinical signs of soft tissue inflammation were reduced after surgical therapy in most test and control sites. While the analysis of bone level alterations in radiographs together with histological and microbiological assessments of resolution of peri-implantitis lesions failed to demonstrate statistically significant differences between test and control procedures, the evaluations disclosed significant differences between implant D and implants A, B and C on treatment outcome. It is suggested that (i) the local use of chlorhexidine has minor influence on treatment outcome, (ii) resolution of peri-implantitis following surgical treatment without the adjunctive use of local and systemic antimicrobial agents is possible and (iii) the results are influenced by implant surface characteristics. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  2. Prosthetically directed implant placement using computer software to ensure precise placement and predictable prosthetic outcomes. Part 2: rapid-prototype medical modeling and stereolithographic drilling guides requiring bone exposure.

    PubMed

    Rosenfeld, Alan L; Mandelaris, George A; Tardieu, Philippe B

    2006-08-01

    The purpose of this paper is to expand on part 1 of this series (published in the previous issue) regarding the emerging future of computer-guided implant dentistry. This article will introduce the concept of rapid-prototype medical modeling as well as describe the utilization and fabrication of computer-generated surgical drilling guides used during implant surgery. The placement of dental implants has traditionally been an intuitive process, whereby the surgeon relies on mental navigation to achieve optimal implant positioning. Through rapid-prototype medical modeling and the ste-reolithographic process, surgical drilling guides (eg, SurgiGuide) can be created. These guides are generated from a surgical implant plan created with a computer software system that incorporates all relevant prosthetic information from which the surgical plan is developed. The utilization of computer-generated planning and stereolithographically generated surgical drilling guides embraces the concept of collaborative accountability and supersedes traditional mental navigation on all levels of implant therapy.

  3. A new surgical and technical approach in zygomatic implantology

    PubMed Central

    GRECCHI, F.; BIANCHI, A.E.; SIERVO, S.; GRECCHI, E.; LAURITANO, D.

    2017-01-01

    SUMMARY Purpose Different surgical approaches for zygomatic implantology using new designed implants are reported. Material and methods The surgical technique is described and two cases reported. The zygomatic fixture has a complete extrasinus path in order to preserve the sinus membrane and to avoid any post-surgical sinus sequelae. Results The surgical procedure allows an optimal position of the implant and consequently an ideal emergence of the fixture on the alveolar crest. Conclusion The surgical procedures and the zygomatic implant design reduce remarkably the serious post-operative sequelae due to the intrasinus path of the zygomatic fixtures. PMID:29876045

  4. Placement of intracoelomic radio transmitters and silicone passive sampling devices in northern leopard frogs (Lithobates pipiens)

    USGS Publications Warehouse

    Yaw, Taylor; Swanson, Jennifer E; Pierce, Clay; Muths, Erin L.; Smalling, Kelly; Vandever, Mark; Zaffarano, Bianca Anne

    2017-01-01

    Historically, wetland toxin exposure studies have relied on single time point samples from stationary sampling devices. Development of passive sampling devices (PSDs) that can be attached to individual animals within wetland habitats has greatly improved in recent years, presenting an innovative sampling technology that can potentially yield individual-specific, quantifiable data about chemical exposure. In this study, silicone based PSDs were attached to the ventral skin of 20 northern leopard frogs (Lithobates pipiens) with polypropylene sutures after radio transmitters had been surgically implanted into the coleomic cavity. After a recovery period frogs were released back into the wetland habitat where they were acquired. The animals were located daily using radio telemetry to assess how long PSDs would remain attached in the frogs' natural habitat. After one week, PSDs remained on 18 of the original 20 frogs. At 2 weeks 17 frogs were recovered and no PSDs remained attached. Although valuable data can be obtained over a short time period, more research will be necessary to demonstrate effectiveness of externally attaching silicone PSDs to northern leopard frogs for time periods longer than 1-2 weeks.

  5. Development of the implant surgical technique and assessment rating system

    PubMed Central

    Park, Jung-Chul; Hwang, Ji-Wan; Lee, Jung-Seok; Jung, Ui-Won; Choi, Seong-Ho; Cho, Kyoo-Sung; Chai, Jung-Kiu

    2012-01-01

    Purpose There has been no attempt to establish an objective implant surgical evaluation protocol to assess residents' surgical competence and improve their surgical outcomes. The present study presents a newly developed assessment and rating system and simulation model that can assist the teaching staffs to evaluate the surgical events and surgical skills of residents objectively. Methods Articles published in peer-reviewed English journals were selected using several scientific databases and subsequently reviewed regarding surgical competence and assessment tools. Particularly, medical journals reporting rating and evaluation protocols for various types of medical surgeries were thoroughly analyzed. Based on these studies, an implant surgical technique assessment and rating system (iSTAR) has been developed. Also, a specialized dental typodont was developed for the valid and reliable assessment of surgery. Results The iSTAR consists of two parts including surgical information and task-specific checklists. Specialized simulation model was subsequently produced and can be used in combination with iSTAR. Conclusions The assessment and rating system provided may serve as a reference guide for teaching staffs to evaluate the residents' implant surgical techniques. PMID:22413071

  6. Infective endocarditis following Melody valve implantation: comparison with a surgical cohort.

    PubMed

    O'Donnell, Clare; Holloway, Rhonda; Tilton, Elizabeth; Stirling, John; Finucane, Kirsten; Wilson, Nigel

    2017-03-01

    Infective endocarditis has been reported post Melody percutaneous pulmonary valve implant; the incidence and risk factors, however, remain poorly defined. We identified four cases of endocarditis from our first 25 Melody implants. Our aim was to examine these cases in the context of postulated risk factors and directly compare endocarditis rates with local surgical valves. We conducted a retrospective review of patients post Melody percutaneous pulmonary valve implant in New Zealand (October, 2009-May, 2015) and also reviewed the incidence of endocarditis in New Zealand among patients who have undergone surgical pulmonary valve implants. In total, 25 patients underwent Melody implantation at a median age of 18 years. At a median follow-up of 2.9 years, most were well with low valve gradient (median 27 mmHg) and only mild regurgitation. Two patients presented with life-threatening endocarditis and obstructive vegetations at 14 and 26 months post implant, respectively. Two additional patients presented with subacute endocarditis at 5.5 years post implant. From 2009 to May, 2015, 178 surgical pulmonic bioprostheses, largely Hancock valves and homografts, were used at our institution. At a median follow-up of 2.9 years, four patients (2%) had developed endocarditis in this group compared with 4/25 (16%) in the Melody group (p=0.0089). Three surgical valves have been replaced. The Melody valve offers a good alternative to surgical conduit replacement in selected patients. Many patients have excellent outcomes in the medium term. Endocarditis, however, can occur and if associated with obstruction can be life threatening. The risk for endocarditis in the Melody group was higher in comparison with that in a contemporaneous surgical pulmonary implant cohort.

  7. Development of Implantable Wireless Sensor Nodes for Animal Husbandry and MedTech Innovation.

    PubMed

    Lu, Jian; Zhang, Lan; Zhang, Dapeng; Matsumoto, Sohei; Hiroshima, Hiroshi; Maeda, Ryutaro; Sato, Mizuho; Toyoda, Atsushi; Gotoh, Takafumi; Ohkohchi, Nobuhiro

    2018-03-26

    In this paper, we report the development, evaluation, and application of ultra-small low-power wireless sensor nodes for advancing animal husbandry, as well as for innovation of medical technologies. A radio frequency identification (RFID) chip with hybrid interface and neglectable power consumption was introduced to enable switching of ON/OFF and measurement mode after implantation. A wireless power transmission system with a maximum efficiency of 70% and an access distance of up to 5 cm was developed to allow the sensor node to survive for a duration of several weeks from a few minutes' remote charge. The results of field tests using laboratory mice and a cow indicated the high accuracy of the collected biological data and bio-compatibility of the package. As a result of extensive application of the above technologies, a fully solid wireless pH sensor and a surgical navigation system using artificial magnetic field and a 3D MEMS magnetic sensor are introduced in this paper, and the preliminary experimental results are presented and discussed.

  8. Maxillary Three-Implant Overdentures Opposing Mandibular Two-Implant Overdentures: 10-Year Surgical Outcomes of a Randomized Controlled Trial.

    PubMed

    Ma, Sunyoung; Tawse-Smith, Andrew; De Silva, Rohana K; Atieh, Momen A; Alsabeeha, Nabeel H M; Payne, Alan G T

    2016-06-01

    The surgical placement of four maxillary implants for overdentures may not be obligatory when opposing mandibular two-implant overdentures. To determine 10-year surgical outcomes and implant success of three narrow diameter implants in edentulous maxillae with conventional loading. Forty participants with mandibular two-implant overdentures were randomly allocated for surgery for maxillary overdentures. Using osteotomes, three implants of similar systems were placed with a one-stage procedure and 12-week loading with splinted and unsplinted prosthodontic designs. Marginal bone and stability measurements were done at surgery, 12 weeks, 1-, 2-, 5-, 7-, 10 years. One hundred seventeen implants were placed in 39 participants, with 35 being seen at 1 year; 29 at 2 years; 28 at 5 years; 26 at 7 years; and 23 (59%) at 10 years. Marginal bone loss was 1.35 mm between surgery and 12 weeks; 0.36 mm between 12 weeks and 1 year; 0.48 mm between 1 and 5 years; and 0.22 mm between 5 and 10 years. Implant stability quotients were 56.05, 57.54, 60.88, 58.80, 61.17 at surgery, 12 weeks, 1 year, 5 years, and 10 years. Four-field tables by implant showed success rates of 82% at 1 year; 69.2% at 2 years; 66.7% at 5 years; 61.5% at 7 years; 51.3% at 10 years. Data showed no differences between surgical technique, systems, or prosthodontic designs. Surgical placement with osteotomes of three narrow diameter implants for maxillary overdentures, opposing mandibular two-implant overdentures, is an acceptable approach, subject to strict patient selection. Implant success is independent of prosthodontic design. © 2015 Wiley Periodicals, Inc.

  9. Implantation, removal and replacement of subretinal electronic implants for restoration of vision in patients with retinitis pigmentosa.

    PubMed

    Gekeler, Katrin; Bartz-Schmidt, Karl Ulrich; Sachs, Helmut; MacLaren, Robert E; Stingl, Katarina; Zrenner, Eberhart; Gekeler, Florian

    2018-05-01

    The purpose of this review is to provide an update on the efforts to restore vision through subretinal implants in patients with degenerative retinal diseases. In addition to the current technique and its latest improvements, it will focus on the surgical technique of implantation as well as explantation and reimplantation. The durability of the current subretinal implant RETINA IMPLANT Alpha AMS has increased substantially compared with the predecessor model RETINA IMPLANT Alpha IMS. According to validated examinations in the laboratory, a median lifetime of 4.7 years will be reached in clinical use; in similar examinations, the previous model has reached only 8 months. Visual function has slightly increased. The surgical technique for subretinal implants is complex and demanding for ophthalmic surgeons, as it is multifaceted and combines novel surgical steps in areas, which are not commonly entered such as the suprachoroidal and the subretinal space. The surgical approach for implantation has matured considerably and has led to successful implantation in 64 patient cases. Surgical challenges are now mainly encountered with the exact subfoveal positioning of the device. The explantation procedure is relatively straight-forward because the implant can be withdrawn in a reverse direction along the already existent subretinal path. Reimplantations, however, are more challenging because some degree of scar tissue may exist along the path of the chip and around the scleral trapdoor. Nevertheless, reimplantations have now been carried out successfully in four patients. The new RETINA IMPLANT Alpha AMS shows significantly improved durability compared with the predecessor model RETINA IMPLANT Alpha IMS. The subretinal implant offers excellent visual results but requires experienced surgeons. Explantation of devices is straight-forward, and reimplantations are challenging but have been successful in four patients.

  10. Wearable Wireless Telemetry System for Implantable BioMEMS Sensors

    NASA Technical Reports Server (NTRS)

    Simons, Rainee N.; Miranda, Felix A.; Wilson, Jeffrey D.; Simons, Renita E.

    2008-01-01

    Telemetry systems of a type that have been proposed for the monitoring of physiological functions in humans would include the following subsystems: Surgically implanted or ingested units that would comprise combinations of microelectromechanical systems (MEMS)- based sensors [bioMEMS sensors] and passive radio-frequency (RF) readout circuits that would include miniature loop antennas. Compact radio transceiver units integrated into external garments for wirelessly powering and interrogating the implanted or ingested units. The basic principles of operation of these systems are the same as those of the bioMEMS-sensor-unit/external-RFpowering- and-interrogating-unit systems described in "Printed Multi-Turn Loop Antennas for Biotelemetry" (LEW-17879-1) NASA Tech Briefs, Vol. 31, No. 6 (June 2007), page 48, and in the immediately preceding article, "Hand-Held Units for Short-Range Wireless Biotelemetry" (LEW-17483-1). The differences between what is reported here and what was reported in the cited prior articles lie in proposed design features and a proposed mode of operation. In a specific system of the type now proposed, the sensor unit would comprise mainly a capacitive MEMS pressure sensor located in the annular region of a loop antenna (more specifically, a square spiral inductor/ antenna), all fabricated as an integral unit on a high-resistivity silicon chip. The capacitor electrodes, the spiral inductor/antenna, and the conductor lines interconnecting them would all be made of gold. The dimensions of the sensor unit have been estimated to be about 110.4 mm. The external garment-mounted powering/ interrogating unit would include a multi-turn loop antenna and signal-processing circuits. During operation, this external unit would be positioned in proximity to the implanted or ingested unit to provide for near-field, inductive coupling between the loop antennas, which we have as the primary and secondary windings of an electrical transformer.

  11. Surgical management of fibrotic encapsulation of the fluocinolone acetonide implant in CAPN5-associated proliferative vitreoretinopathy

    PubMed Central

    Tlucek, Paul S; Folk, James C; Sobol, Warren M; Mahajan, Vinit B

    2013-01-01

    Objective To review fibrosis of fluocinolone acetonide (FA) implants in subjects with CAPN5 autosomal dominant neovascular inflammatory vitreoretinopathy (ADNIV). Methods A retrospective case series was assembled from ADNIV patients in which there was fibrotic encapsulation of a fluocinolone acetonide implant. CAPN5 genotypes and surgical repair techniques were reviewed. Results Two eyes of two ADNIV patients developed a fibrotic capsule over the fluocinolone acetonide implant. Both patients had Stage IV disease. Patient A had a c.731T > C mutation in the CAPN5 gene and patient B had a c.728G > T mutation. The fibrotic membrane was surgically excised and the implant function was restored. Conclusion The exuberant fibrotic response in later stages of ADNIV may be resistant to local immunosuppression with steroids. Surgical excision of fibrotic membranes over FA implants can reestablish local steroid delivery in cases of severe proliferative vitreoretinopathy. PMID:23785231

  12. Surgical management of fibrotic encapsulation of the fluocinolone acetonide implant in CAPN5-associated proliferative vitreoretinopathy.

    PubMed

    Tlucek, Paul S; Folk, James C; Sobol, Warren M; Mahajan, Vinit B

    2013-01-01

    To review fibrosis of fluocinolone acetonide (FA) implants in subjects with CAPN5 autosomal dominant neovascular inflammatory vitreoretinopathy (ADNIV). A retrospective case series was assembled from ADNIV patients in which there was fibrotic encapsulation of a fluocinolone acetonide implant. CAPN5 genotypes and surgical repair techniques were reviewed. Two eyes of two ADNIV patients developed a fibrotic capsule over the fluocinolone acetonide implant. Both patients had Stage IV disease. Patient A had a c.731T > C mutation in the CAPN5 gene and patient B had a c.728G > T mutation. The fibrotic membrane was surgically excised and the implant function was restored. The exuberant fibrotic response in later stages of ADNIV may be resistant to local immunosuppression with steroids. Surgical excision of fibrotic membranes over FA implants can reestablish local steroid delivery in cases of severe proliferative vitreoretinopathy.

  13. Surgical positioning of orthodontic mini-implants with guides fabricated on models replicated with cone-beam computed tomography.

    PubMed

    Kim, Seong-Hun; Choi, Yong-Suk; Hwang, Eui-Hwan; Chung, Kyu-Rhim; Kook, Yoon-Ah; Nelson, Gerald

    2007-04-01

    This article illustrates a new surgical guide system that uses cone-beam computed tomography (CBCT) images to replicate dental models; surgical guides for the proper positioning of orthodontic mini-implants were fabricated on the replicas, and the guides were used for precise placement. The indications, efficacy, and possible complications of this method are discussed. Patients who were planning to have orthodontic mini-implant treatment were recruited for this study. A CBCT system (PSR 9000N, Asahi Roentgen, Kyoto, Japan) was used to acquire virtual slices of the posterior maxilla that were 0.1 to 0.15 mm thick. Color 3-dimensional rapid prototyping was used to differentiate teeth, alveolus, and maxillary sinus wall. A surgical guide for the mini-implant was fabricated on the replica model. Proper positioning for mini-implants on the posterior maxilla was determined by viewing the CBCT images. The surgical guide was placed on the clinical site, and it allowed precise pilot drilling and accurate placement of the mini-implant. CBCT imaging allows remarkably lower radiation doses and thinner acquisition slices compared with medical computed tomography. Virtually reproduced replica models enable precise planning for mini-implant positions in anatomically complex sites.

  14. The ethical allocation of scarce resources in surgery: implants and cost

    PubMed Central

    Gross, Michael

    1997-01-01

    This paper is a discussion of the factors involved in instituting a bulk purchasing program for surgical supplies. An improved understanding of the surgical procedure of joint arthroplasty must relate to the variability in surgical methods that achieve patient outcomes. An understanding of the outcomes in relation to the expected duration of the success of an implant and the high costs associated with a revision earlier than expected must be factored into the budget and costs of implants. The ethical implications of choosing one implant over another are considered. A more uniform outcome assessment with respect to surgical activities is needed and potential savings related to other operating-room costs must be examined. Optimizing the implant to patient requirements is the goal within the framework of current fiscal constraints. PMID:9416251

  15. Implantable radio frequency identification sensors: wireless power and communication.

    PubMed

    Hutchens, Chriswell; Rennaker, Robert L; Venkataraman, Srinivasan; Ahmed, Rehan; Liao, Ran; Ibrahim, Tamer

    2011-01-01

    There are significant technical challenges in the development of a fully implantable wirelessly powered neural interface. Challenges include wireless transmission of sufficient power to the implanted device to ensure reliable operation for decades without replacement, minimizing tissue heating, and adequate reliable communications bandwidth. Overcoming these challenges is essential for the development of implantable closed loop system for the treatment of disorders ranging from epilepsy, incontinence, stroke and spinal cord injury. We discuss the development of the wireless power, communication and control for a Radio-Frequency Identification Sensor (RFIDS) system with targeted power range for a 700 mV, 30 to 40 uA load attained at -2 dBm.

  16. Linguine sign at MR imaging: does it represent the collapsed silicone implant shell?

    PubMed

    Gorczyca, D P; DeBruhl, N D; Mund, D F; Bassett, L W

    1994-05-01

    One intact and one ruptured single-lumen implant were surgically placed in a rabbit. Magnetic resonance (MR) imaging was performed before and after surgical removal, and the ruptured implant was imaged after removal of the implant shell. Multiple curvilinear hypointense lines (linguine sign) were present in the MR images of the ruptured implant and of the implant shell alone immersed in saline solution but not in the image of the free silicone. The collapsed implant shell in a ruptured silicone implant does cause the linguine sign.

  17. Accuracy of a real-time surgical navigation system for the placement of quad zygomatic implants in the severe atrophic maxilla: A pilot clinical study.

    PubMed

    Hung, Kuo-Feng; Wang, Feng; Wang, Hao-Wei; Zhou, Wen-Jie; Huang, Wei; Wu, Yi-Qun

    2017-06-01

    A real-time surgical navigation system potentially increases the accuracy when used for quad-zygomatic implant placement. To evaluate the accuracy of a real-time surgical navigation system when used for quad zygomatic implant placement. Patients with severely atrophic maxillae were prospectively recruited. Four trajectories for implants were planned, and zygomatic implants were placed using a real-time surgical navigation system. The planned-placed distance deviations at entry (entry deviation)points, exit (exit deviation) points, and angle deviation of axes (angle deviation) were measured on fused operation images. The differences of all the deviations between different groups, classified based on the lengths and locations of implants, were analysed. A P value of < 0.05 indicated statistical significance. Forty zygomatic implants were placed as planned in 10 patients. The entry deviation, exit deviation and angle deviation were 1.35 ± 0.75 mm, 2.15 mm ± 0.95 mm, and 2.05 ± 1.02 degrees, respectively. The differences of all deviations were not significant, irrespective of the lengths (P = .259, .158, and .914, respectively) or locations of the placed implants (P = .698, .072, and .602, respectively). A real-time surgical navigation system used for the placement of quad zygomatic implants demonstrated a high level of accuracy with only minimal planned-placed deviations, irrespective of the lengths or locations of the implants. © 2017 Wiley Periodicals, Inc.

  18. Radio telemetry for black-footed ferret research and monitoring

    USGS Publications Warehouse

    Biggins, Dean E.; Godbey, Jerry L.; Miller, Brian J.; Hanebury, Louis R.

    2006-01-01

    By 1973, radio telemetry was regarded as an important potential tool for studying the elusive, nocturnal, and semifossorial black-footed ferret (Mustela nigripes), but fears of using invasive techniques on this highly endangered mammal caused delays. We began radio collaring ferrets in 1981. Use of radio telemetry on ferrets proved to be both challenging and rewarding. We document two decades of development and use that led to the present radio-tagging techniques and methods for radio tracking. The 7-g radio collar commonly used after 1992 was smaller and lighter, relative to mass and size of subjects, than collars used in studies of other Mustela. Other important developments were a Teflon® coating to shed mud, a highly flexible stainless steel cable for whip antennas, and a nondurable wool collar. Although collar-caused neck abrasions have continued to occur sporadically, a retrospective assessment of minimum survival rates for 724 reintroduced ferrets (392 radio tagged), using data from spotlight surveys, failed to detect negative effects of radio-collars. In a South Dakota study, ferrets that were found to have hair loss or neck abrasions when collars were removed did not exhibit movements significantly different from those of radio-tagged ferrets with no evidence of neck problems. Prototype transmitters designed for surgical implantation had insufficient power output for effective use on ferrets. Early attempts at tracking radio-tagged ferrets by following the signal on foot quickly gave way to following movements by triangulation, which does not disturb the subjects. The most effective tracking stations were camper trailers fitted with rotatable, 11-element, dual-beam Yagi antennas on 6-m masts. We used radio telemetry to produce 83,275 lines of data (44,191 indications of status and 39,084 positional fixes via triangulation) for 340 radio-collared ferrets during the reintroduction program. Tracking by hand and from aircraft augmented triangulation, allowing us to locate animals that dispersed long distances and enabling us to determine causes of mortality. Justifying further use of radio telemetry on black-footed ferrets requires careful consideration of costs and benefits.

  19. 47 CFR 95.1209 - Permissible communications.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... to which the MedRadio implant or body-worn transmitter is used. (c) MedRadio programmer/control...Radio programmer/control transmitters may transmit only non-voice data containing operational... shall transmit except in response to a transmission from a MedRadio programmer/control transmitter or in...

  20. Immediate Implants: Clinical Guidelines for Esthetic Outcomes

    PubMed Central

    Javaid, Mohammad A.; Khurshid, Zohaib; Zafar, Muhammad S.; Najeeb, Shariq

    2016-01-01

    Research has shown that tooth loss results in morphological changes in alveolar ridge that may influence the subsequent implant placement. Immediate implant placement was introduced as a possible means to limit bone resorption and reduce the number of surgical procedures following tooth extraction. Histological and clinical evidence from human clinical studies showing efficacy of immediate implants has come to light over the last decade or so. However, immediate implant placement is a challenging surgical procedure and requires proper case selection and surgical technique. Furthermore, there appears to be a lack of clinical guidelines for immediate implant placement case selection. Therefore, the aim of this mini-review is to analyze critical evidence from human studies in order to establish clinical guidelines which may help clinicians in case selection when considering immediate implant placement protocol. PMID:29563463

  1. Retrospective analysis of dental implants placed and restored by advanced prosthodontic residents.

    PubMed

    Barias, Pamela A; Lee, Damian J; Yuan, Judy Chia-Chun; Sukotjo, Cortino; Campbell, Stephen D; Knoernschild, Kent L

    2013-02-01

    The purposes of this retrospective clinical review were to: (1) describe the demographics of implant patients, types of implant treatment and implant-supported prostheses in an Advanced Education in Prosthodontic Program, (2) evaluate the survival rate of dental implants placed by prosthodontic residents from 2006 to 2008, and (3) analyze the relationship between resident year of training and implant survival rate. All patients who received dental implants placed by prosthodontic residents from January 2006 to October of 2008 in the Advanced Prosthodontic Program at the University of Illinois at Chicago College of Dentistry were selected for this study. Age, gender, implant diameter, length, implant locations, surgical and restorative detail, and year of prosthodontic residency training were collected and analyzed. Life-table and Kaplan-Meier survival analyses were performed based on implants overall, locations, year of training, and use of a computer-generated surgical guide. A Logrank statistic was performed between implant survival and year of prosthodontic residency training, location, and use of computer-generated surgical guide (α= 0.05). Three hundred and six implants were placed, and of these, seven failed. Life-table and Kaplan-Meier analyses computed a cumulative survival rate (CSR) of 97% for overall implants and implants placed with a computer-generated surgical guide. No statistical difference was found in implant survival rates as a function of year of training (P= 0.85). Dental implants placed by prosthodontic residents had a CSR comparable to previously published studies by other specialties. The year of prosthodontic residency training and implant failure rate did not have any significant relationship. © 2012 by the American College of Prosthodontists.

  2. Post-Surgical Clinical Monitoring of Soft Tissue Wound Healing in Periodontal and Implant Surgery

    PubMed Central

    Pippi, Roberto

    2017-01-01

    Clinical features of surgical soft tissue wound healing in dentistry have been rarely discussed in the international literature. The aim of the present paper is to highlight both the main clinical findings of surgical wound healing, especially in periodontal and implant dentistry, and the wound healing monitoring procedures which should be followed. Wound inspection after careful food and plaque debridement is the essential part of wound healing monitoring. Periodontal and peri-implant probing should be performed only after tissue healing has been completed and not on a weekly basis in peri-implant tissue monitoring. Telephone follow-up and patient self-assessment scales can also be used the days following surgery to monitor the most common surgical complications such as pain, swelling, bleeding, and bruising. Wound healing monitoring is an important concern in all surgical procedures since it allows to identify signs or/and symptoms possibly related to surgical complications. PMID:28824306

  3. Post-Surgical Clinical Monitoring of Soft Tissue Wound Healing in Periodontal and Implant Surgery.

    PubMed

    Pippi, Roberto

    2017-01-01

    Clinical features of surgical soft tissue wound healing in dentistry have been rarely discussed in the international literature. The aim of the present paper is to highlight both the main clinical findings of surgical wound healing, especially in periodontal and implant dentistry, and the wound healing monitoring procedures which should be followed. Wound inspection after careful food and plaque debridement is the essential part of wound healing monitoring. Periodontal and peri-implant probing should be performed only after tissue healing has been completed and not on a weekly basis in peri-implant tissue monitoring. Telephone follow-up and patient self-assessment scales can also be used the days following surgery to monitor the most common surgical complications such as pain, swelling, bleeding, and bruising. Wound healing monitoring is an important concern in all surgical procedures since it allows to identify signs or/and symptoms possibly related to surgical complications.

  4. Combustion Synthesis of Ca3(PO4)2 Net-Shape Surgical Implants

    NASA Technical Reports Server (NTRS)

    Ayers, Reed A.; Castillo, Martin; Gottoli, Guglielmo; Moore, John J.; Simske, Steven J.

    2006-01-01

    Self-propagating high-temperature combustion synthesis (SHS) is the basis of a method of making components of porous tricalcium phosphate [Ca3(PO4)2] and related compounds in net sizes and shapes for use as surgical implants that are compatible with bone. The SHS method offers advantages over prior methods of manufacturing Ca3(PO4)2-based surgical implants.

  5. Accuracy of a cone beam computed tomography-guided surgical stent for orthodontic mini-implant placement.

    PubMed

    Yu, Jae-Jung; Kim, Gyu-Tae; Choi, Yong-Suk; Hwang, Eui-Hwan; Paek, Janghyun; Kim, Seong-Hun; Huang, John C

    2012-03-01

    To validate the accuracy of a cone-beam computed tomography (CBCT)-guided surgical stent for orthodontic mini-implant (OMI) placement by quantitatively evaluating the difference between CBCT-prescribed and actual position of mini-implants in preoperative and postoperative CBCT images. A surgical stent was fabricated using Teflon-Perfluoroalkoxy, which has appropriate biological x-ray attenuation properties. Polyvinylsiloxane impression material was used to secure the custom-made surgical stent onto swine mandibles. CBCT scanning was done with the stent in place to virtually plan mini-implants using a three-dimensional (3D) software program. An appropriate insertion point was determined using 3D reconstruction data, and the vertical and horizontal angulations were determined using four prescribed angles. A custom-designed surveyor was used to drill a guide hole within the surgical stent as prescribed on the CBCT images for insertion of 32 OMIs. The mandibles with a surgical stent in place were rescanned with CBCT to measure the deviations between the virtual planning data and surgical results. The difference between the prescribed and actual vertical angle was 1.01 ± 7.25, and the horizontal difference was 1.16 ± 6.08. The correlation coefficient confirms that there was no intrarater variability in either the horizontal (R  =  .97) or vertical (R  =  .74) vectors. The surgical stent in this study guides mini-implants to the prescribed position as planned in CBCT. Since the statistical difference was not significant, the surgical stent can be considered to be an accurate guide tool for mini-implant placement in clinical use.

  6. The combination of digital surface scanners and cone beam computed tomography technology for guided implant surgery using 3Shape implant studio software: a case history report.

    PubMed

    Lanis, Alejandro; Álvarez Del Canto, Orlando

    2015-01-01

    The incorporation of virtual engineering into dentistry and the digitization of information are providing new perspectives and innovative alternatives for dental treatment modalities. The use of digital surface scanners with surgical planning software allows for the combination of the radiographic, prosthetic, surgical, and laboratory fields under a common virtual scenario, permitting complete digital treatment planning. In this article, the authors present a clinical case in which a guided implant surgery was performed based on a complete digital surgical plan combining the information from a cone beam computed tomography scan and the virtual simulation obtained from the 3Shape TRIOS intraoral surface scanner. The information was imported to and combined in the 3Shape Implant Studio software for guided implant surgery planning. A surgical guide was obtained by a 3D printer, and the surgical procedure was done using the Biohorizons Guided Surgery Kit and its protocol.

  7. Effect of surgical guide design and surgeon's experience on the accuracy of implant placement.

    PubMed

    Hinckfuss, Simon; Conrad, Heather J; Lin, Lianshan; Lunos, Scott; Seong, Wook-Jin

    2012-08-01

    Implant position is a key determinant of esthetic and functional success. Achieving the goal of ideal implant position may be affected by case selection, prosthodontically driven treatment planning, site preparation, surgeon's experience and use of a surgical guide. The combined effect of surgical guide design, surgeon's experience, and size of the edentulous area on the accuracy of implant placement was evaluated in a simulated clinical setting. Twenty-one volunteers were recruited to participate in the study. They were divided evenly into 3 groups (novice, intermediate, and experienced). Each surgeon placed implants in single and double sites using 4 different surgical guide designs (no guide, tube, channel, and guided) and written instructions describing the ideal implant positions. A definitive typodont was constructed that had 3 implants in prosthetically determined ideal positions of single and double sites. The position and angulation of implants placed by the surgeons in the duplicate typodonts was measured using a computerized coordinate measuring machine and compared to the definitive typodont. The mean absolute positional error for all guides was 0.273, 0.340, 0.197 mm in mesial-distal, buccal-lingual, vertical positions, respectively, with an overall range of 0.00 to 1.81 mm. The mean absolute angle error for all guides was 1.61° and 2.39° in the mesial-distal and buccal-lingual angulations, respectively, with an overall range of 0.01° to 9.7°. Surgical guide design had a statistically significant effect on the accuracy of implant placement regardless of the surgeon's experience level. Experienced surgeons had significantly less error in buccal-lingual angulation. The size of the edentulous sites was found to affect both implant angle and position significantly. The magnitude of error in position and angulation caused by surgical guide design, surgeon's experience, and site size reported in this study are possibly not large enough to be clinically significant; however, it is likely that errors would be magnified in clinical practice. Future research is recommended to evaluate the effect of surgical guide design in vivo on implant angulation and position error.

  8. Surgical Management of the Pediatric Cochlear Implant Patient.

    ERIC Educational Resources Information Center

    Cohen, Seth M.; Haynes, David S.

    2003-01-01

    This article discusses the surgical management of children receiving cochlear implants. It identifies preoperative considerations to select patients likely to benefit, contraindications, some new surgical techniques, complications, special considerations (otitis media, meningitis, head growth, inner ear malformations, and cochlear obstruction).…

  9. Does wearing a surgical facemask or N95-respirator impair radio communication?

    PubMed

    Thomas, Frank; Allen, Craig; Butts, William; Rhoades, Carol; Brandon, Cynthia; Handrahan, Diana L

    2011-01-01

    This study evaluated the impact wearing a surgical facemask or N95 air purifying respirator (N95) has on radio reception. We compared the ability of a flight crewmember and a layperson sitting in a Bell 407 crew compartment and a dispatcher sitting in a communication center to accurately record 20 randomized aviation terms transmitted over the radio by a helicopter emergency medical services (HEMS) pilot wearing a surgical facemask and six different N95s with and without the aircraft engine operating. With the aircraft engine off, all terms (100% accuracy) were correctly identified, regardless of the absence or presence of the surgical facemask or N95 studied. With the aircraft engine on, the surgical facemask (3M-1826) and two N95 respirators (3M-1860, Safe Life Corp-150) maintained 100% accuracy. Remaining N95 accuracy was as follows: 3M-8511 and Kimberly-Clark PFR95 (98%), Inoyel-3212 (97%), and 3M-1870 (93%). In general, despite wearing a facemask, radio reception accuracy is high (>90%). However, aircraft engine noise and N95 type do appear to adversely affect the accuracy of radio reception. All HEMS pilots and crewmembers should be aware of these radio reception findings when using an N95 respirator during transport. A brief review of the surgical facemask and N95 effectiveness to prevent viral respiratory infections is provided. Copyright © 2011 Air Medical Journal Associates. Published by Elsevier Inc. All rights reserved.

  10. Surgical Outcomes of Additional Ahmed Glaucoma Valve Implantation in Refractory Glaucoma.

    PubMed

    Ko, Sung Ju; Hwang, Young Hoon; Ahn, Sang Il; Kim, Hwang Ki

    2016-06-01

    To evaluate the surgical outcomes of the implantation of an additional Ahmed glaucoma valve (AGV) into the eyes of patients with refractory glaucoma following previous AGV implantation. This study is a retrospective review of the clinical histories of 23 patients who had undergone a second AGV implantation after a failed initial implantation. Age, sex, prior surgery, glaucoma type, number of medications, intraocular pressure (IOP), visual acuity, and surgical complications were analyzed. Surgical success was defined as IOP maintained below 21 mm Hg, with at least a 20% overall reduction in IOP, regardless of the use of IOP-lowering medications. Following the implantation of a second AGV, the mean IOP decreased from 39.3 to 18.5 mm Hg (52.9% reduction, P<0.001). The mean number of postoperative IOP-lowering medications administered decreased from 2.8 to 1.7 after the second AGV implantation (P<0.001). The cumulative probability of success for the procedure was 87% after 1 year and 52% after 3 years. Three patients (13.0%) experienced bullous keratopathy after the second AGV implantation. None of the patients showed any evidence of diplopia or ocular movement limitation as a result of the presence of 2 AGVs in the same eye. Prior trabeculectomy was found to be a significant risk factor for failure (P=0.027). A second AGV implantation can be a good choice of surgical treatment when the first AGV has failed to control IOP.

  11. Corrosion and fatigue of surgical implants

    NASA Technical Reports Server (NTRS)

    Lisagor, W. B.

    1975-01-01

    Implants for the treatment of femoral fractures, mechanisms leading to the failure or degradation of such structures, and current perspectives on surgical implants are discussed. Under the first heading, general usage, materials and procedures, environmental conditions, and laboratory analyses of implants after service are considered. Corrosion, crevice corrosion, stress corrosion cracking, intergranular corrosion, pitting corrosion, fatigue, and corrosion fatigue are the principal degradation mechanisms described. The need for improvement in the reliability of implants is emphasized.

  12. Peri-implant plastic surgery techniques to hard and soft tissue augmentation in implant rehabilitation

    PubMed Central

    Baltacioğlu, Esra; Korkmaz, Yavuz Tolga; Korkmaz, Fatih Mehmet; Aydin, Güven; Sukuroglu, Erkan

    2017-01-01

    This report presents the clinical results of peri-implant plastic surgical approaches for hard and soft tissues before and during the implant placement in a patient with vertical ridge deformation and a shallow vestibule sulcus, and the subsequently performed prosthetic rehabilitation. The surgical approaches used in this case reduced the crown-height space and crown-to-implant ratio and ensured that the implants were placed in their ideal positions, and peri-implant tissue health was maintained. In conclusion, developments in the peri-implant plastic surgery enable the successful augmentation of hard and soft tissue defects and provide the implant-supported fixed prosthetic rehabilitation. PMID:29386805

  13. Implanting inequality: empirical evidence of social and ethical risks of implantable radio-frequency identification (RFID) devices.

    PubMed

    Monahan, Torin; Fisher, Jill A

    2010-10-01

    The aim of this study was to assess empirically the social and ethical risks associated with implantable radio-frequency identification (RFID) devices. Qualitative research included observational studies in twenty-three U.S. hospitals that have implemented new patient identification systems and eighty semi-structured interviews about the social and ethical implications of new patient identification systems, including RFID implants. The study identified three primary social and ethical risks associated with RFID implants: (i) unfair prioritization of patients based on their participation in the system, (ii) diminished trust of patients by care providers, and (iii) endangerment of patients who misunderstand the capabilities of the systems. RFID implants may aggravate inequalities in access to care without any clear health benefits. This research underscores the importance of critically evaluating new healthcare technologies from the perspective of both normative ethics and empirical ethics.

  14. Surgically Induced Scleral Necrosis in a Patient With Rheumatoid Arthritis After AGV Implantation.

    PubMed

    Kumar, Suresh; Ichhpujani, Parul; Thakur, Sahil

    2018-03-01

    Surgically induced scleral necrosis (SINS) is a rare entity that has till date not been reported in a patient of glaucoma undergoing Ahmed glaucoma valve (AGV) implantation. We present a case of primary open-angle glaucoma who underwent AGV implantation followed by development of scleral necrosis, involving both the scleral patch graft and host sclera. After failure of surgical and medical management, AGV had to be explanted. The patient was diagnosed with rheumatoid arthritis and had to be treated with steroids and azathioprine for the same. SINS is a potentially disastrous complication of ocular surgery that can occur in patients with systemic diseases like rheumatoid arthritis and requires aggressive management to salvage the eye. SINS can occur with AGV implantation. Treatment may require aggressive medical and surgical intervention. It is imperative to evaluate patients for systemic illness before planning an AGV implant.

  15. Uncovering dental implants using a new thermo-optically powered (TOP) technology with tissue air-cooling.

    PubMed

    Romanos, Georgios E; Belikov, Andrey V; Skrypnik, Alexei V; Feldchtein, Felix I; Smirnov, Michael Z; Altshuler, Gregory B

    2015-07-01

    Uncovering implants with lasers, while bloodless, has been associated with a risk of implant and bone overheating. The present study evaluated the effect of using a new generation of high-power diode lasers on the temperature of a dental implant and the surrounding tissues using an in vitro model. The implant temperature was measured at three locations using micro thermocouples. Collateral thermal damage of uncovered soft tissues was evaluated using NTBC stain. Implant temperature rise during and collateral thermal soft-tissue damage following implant uncovering with and without tissue air-cooling was studied using both the classic operational mode and the new thermo-optically powered (TOP) technology. For the classic surgical mode using a cork-initiated tip and constant laser power set at 3.4 W, the maximum temperature rise in the coronal and apical parts of the implant was 23.2 ± 4.1°С and 9.5 ± 1.8°С, respectively, while 1.5 ± 0.5 mm of collateral thermal damage of the soft tissue surrounding the implant model occurred. Using the TOP surgical tip with constant laser power reduced implant overheating by 30%; collateral thermal soft-tissue damage was 0.8 ± 0.2 mm. Using the TOP surgical mode with a tip temperature setting of 800°C and air-cooling reduced the implant temperature rise by more than 300%, and only 0.2 ± 0.1 mm of collateral thermal soft-tissue damage occurred, typical for optimized CO2 laser surgery. Furthermore, use of the new generation diode technology (TOP surgical mode) appeared to reduce the time required for implant uncovering by a factor of two, compared to the standard surgical mode. Use of the new generation diode technology (TOP surgical mode) may significantly reduce overheating of dental implants during uncovering and seems to be safer for the adjacent soft and hard tissues. Use of such diode lasers with air-cooling can radically reduce the rise in implant temperatures (by more than three times), potentially making this technology safe and effective for implant uncovering. © 2015 Wiley Periodicals, Inc.

  16. Computer-assisted surgery in the lower jaw: double surgical guide for immediately loaded implants in postextractive sites-technical notes and a case report.

    PubMed

    De Santis, Daniele; Canton, Luciano Claudio; Cucchi, Alessandro; Zanotti, Guglielmo; Pistoia, Enrico; Nocini, Pier Francesco

    2010-01-01

    Computer-assisted surgery is based on computerized tomography (CT) scan technology to plan the placement of dental implants and a computer-aided design/computer-aided manufacturing (CAD-CAM) technology to create a custom surgical template. It provides guidance for insertion implants after analysis of existing alveolar bone and planning of implant position, which can be immediately loaded, therefore achieving esthetic and functional results in a surgical stage. The absence of guidelines to treat dentulous areas is often due to a lack of computer-assisted surgery. The authors have attempted to use this surgical methodology to replace residual teeth with an immediate implantoprosthetic restoration. The aim of this case report is to show the possibility of treating a dentulous patient by applying a computer-assisted surgical protocol associated with the use of a double surgical template: one before extraction and a second one after extraction of selected teeth.

  17. Three-Year Outcome of Fixed Partial Rehabilitations Supported by Implants Inserted with Flap or Flapless Surgical Techniques.

    PubMed

    Maló, Paulo; de Araújo Nobre, Miguel; Lopes, Armando

    2016-07-01

    The aim of this prospective clinical study was to evaluate the 3-year outcome of fixed partial prostheses supported by implants with immediate provisionalization without occlusal contacts inserted in predominantly soft bone with flap and flapless protocols. Forty-one patients partially rehabilitated with 72 NobelSpeedy implants (51 maxillary; 21 mandibular) were consecutively included and treated with a flapless surgical protocol (n = 20 patients; 32 implants) and flapped surgical protocol (n = 21 patients; 40 implants). Primary outcome measure was implant survival; secondary outcome measures were marginal bone resorption (comparing the bone levels at 1 and 3 years with baseline) and the incidence of biological, mechanical, and esthetic complications. Survival was computed through life tables; descriptive statistics were applied to the remaining variables of interest. Eight patients with eight implants dropped out of the study. One implant failed in one patient (flapless group) giving an overall cumulative survival rate (CSR) of 98.6%. No failures were noted with the flapped protocol (CSR 100%), while for the implants placed with the flapless surgical technique, a 96.9% CSR was registered. The overall average marginal bone resorption at 3 years was 1.37 mm (SD = 0.94 mm), with 1.14 mm (SD = 0.49 mm) and 1.60 mm (SD = 1.22 mm) for the flap and flapless groups, respectively. Mechanical complications occurred in nine patients (n = 5 patients in the flapless group; n = 4 patients in the flap group). Implant infection was registered in three implants and three patients (flapless group), who exhibited inadequate oral hygiene levels. Partial edentulism rehabilitation through immediate provisionalization fixed prosthesis supported by dental implants inserted through flap or flapless surgical techniques in areas of predominantly soft bone was viable at 3 years of follow-up. The limitations and risks of the "free-hand" method in flapless surgery should be considered when planning implant-supported fixed prosthetic reconstructions. © 2015 by the American College of Prosthodontists.

  18. Physiological Stress Responses to Prolonged Exposure to MS-222 and Surgical Implantation in Juvenile Chinook Salmon

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wagner, Katie A.; Woodley, Christa M.; Seaburg, Adam

    While many studies have investigated the effects of transmitters on fish condition, behavior, and survival, to our knowledge, no studies have taken into account anesthetic exposure time in addition to tag and surgery effects. We investigated stress responses to prolonged MS-222 exposure after stage 4 induction in surgically implanted juvenile Chinook salmon (Oncorhynchus tshawytscha). Survival, tag loss, plasma cortisol concentration, and blood Na +, K +, Ca 2+, and pH were measured immediately following anesthetic exposure and surgical implantation and 1, 7, and 14 days post-treatment. Despite the prolonged anesthetic exposure, 3-15 minutes post Stage 4 induction, there were nomore » mortalities or tag loss in any treatment. MS-222 was effective at delaying immediate cortisol release during surgical implantation; however, osmotic disturbances resulted, which were more pronounced in longer anesthetic time exposures. From day 1 to day 14, Na +, Ca 2+, and pH significantly decreased, while cortisol significantly increased. The cortisol increase was exacerbated by surgical implantation. There was a significant interaction between MS-222 time exposure and observation day for Na +, Ca 2+, K +, and pH; variations were seen in the longer time exposures, although not consistently. In conclusion, stress response patterns suggest stress associated with surgical implantation is amplified with increased exposure to MS-222.« less

  19. The Effect of Non-Infectious Wound Complications after Mastectomy on Subsequent Surgical Procedures and Early Implant Loss

    PubMed Central

    Nickel, Katelin B; Fox, Ida K; Margenthaler, Julie A; Wallace, Anna E; Fraser, Victoria J; Olsen, Margaret A

    2016-01-01

    Background Non-infectious wound complications (NIWCs) following mastectomy are not routinely tracked and data are generally limited to single-center studies. Our objective was to determine the rates of NIWCs among women undergoing mastectomy and assess the impact of immediate reconstruction (IR). Study Design We established a retrospective cohort using commercial claims data of women aged 18–64 years with procedure codes for mastectomy from 1/2004–12/2011. NIWCs within 180 days after operation were identified by ICD-9-CM diagnosis codes and rates were compared among mastectomy with and without autologous flap and/or implant IR. Results 18,696 procedures (10,836 [58%] with IR) among 18,085 women were identified. The overall NIWC rate was 9.2% (1,714/18,696); 56% required surgical treatment. The NIWC rates were 5.8% (455/7,860) after mastectomy-only, 10.3% (843/8,217) after mastectomy + implant, 17.4% (337/1,942) after mastectomy + flap, and 11.7% (79/677) after mastectomy + flap and implant (p<0.001). The rates of individual NIWCs varied by specific complication and procedure type, ranging from 0.5% for fat necrosis after mastectomy-only to 7.2% for dehiscence after mastectomy + flap. The percentage of NIWCs resulting in surgical wound care varied from 50% (210/416) for mastectomy + flap to 60% (507/843) for mastectomy + implant. Early implant removal within 60 days occurred after 6.2% of mastectomy + implant; 66% of the early implant removals were due to NIWCs and/or surgical site infection. Conclusions The rate of NIWC was approximately two-fold higher after mastectomy with IR than after mastectomy-only. NIWCs were associated with additional surgical treatment, particularly in women with implant reconstruction, and with early implant loss. PMID:27010582

  20. Rehabilitation with 4 zygomatic implants with a new surgical protocol using ultrasonic technique.

    PubMed

    Mozzati, Marco; Mortellaro, Carmen; Arata, Valentina; Gallesio, Giorgia; Previgliano, Valter

    2015-05-01

    When the residual bone crest cannot allow the placement of standard implants, the treatment for complete arch rehabilitation of severely atrophic maxillae can be performed with 4 zygomatic implants (ZIs) and immediate function with predictable results in terms of aesthetics, function, and comfort for the patient. However, even if ZIs' rehabilitations showed a good success rate, this surgery is difficult and need a skillful operator. Complications in this kind of rehabilitation are not uncommon; the main difficulties can be related to the reduced surgical visibility and instrument control in a critical anatomic area. All the surgical protocols described in the literature used drilling techniques. Furthermore, the use of ultrasonic instruments in implant surgery compared with drilling instruments have shown advantages in many aspects of surgical procedures, tissues management, enhancement of control, surgical visualization, and healing. The aim of this study was to report on the preliminary experience using ultrasound technique for ZIs surgery in terms of safety and technical improvement. Ten consecutive patients with severely atrophic maxilla have been treated with 4 ZIs and immediate complete arch acrylic resin provisional prostheses. The patients were followed up from 30 to 32 months evaluating implant success, prosthetic success, and patient satisfaction with a questionnaire. No implants were lost during the study period, with a 100% implant and prosthetic success rate. Within the limitations of this preliminary study, these data indicate that ultrasonic implant site preparation for ZIs can be a good alternative to the drilling technique and an improvement for the surgeon.

  1. Accurate pre-surgical determination for self-drilling miniscrew implant placement using surgical guides and cone-beam computed tomography.

    PubMed

    Miyazawa, Ken; Kawaguchi, Misuzu; Tabuchi, Masako; Goto, Shigemi

    2010-12-01

    Miniscrew implants have proven to be effective in providing absolute orthodontic anchorage. However, as self-drilling miniscrew implants have become more popular, a problem has emerged, i.e. root contact, which can lead to perforation and other root injuries. To avoid possible root damage, a surgical guide was fabricated and cone-beam computed tomography (CBCT) was used to incorporate guide tubes drilled in accordance with the planned direction of the implants. Eighteen patients (5 males and 13 females; mean age 23.8 years; minimum 10.7, maximum 45.5) were included in the study. Forty-four self-drilling miniscrew implants (diameter 1.6, and length 8 mm) were placed in interradicular bone using a surgical guide procedure, the majority in the maxillary molar area. To determine the success rates, statistical analysis was undertaken using Fisher's exact probability test. CBCT images of post-surgical self-drilling miniscrew implant placement showed no root contact (0/44). However, based on CBCT evaluation, it was necessary to change the location or angle of 52.3 per cent (23/44) of the guide tubes prior to surgery in order to obtain optimal placement. If orthodontic force could be applied to the screw until completion of orthodontic treatment, screw anchorage was recorded as successful. The total success rate of all miniscrews was 90.9 per cent (40/44). Orthodontic self-drilling miniscrew implants must be inserted carefully, particularly in the case of blind placement, since even guide tubes made on casts frequently require repositioning to avoid the roots of the teeth. The use of surgical guides, fabricated using CBCT images, appears to be a promising technique for placement of orthodontic self-drilling miniscrew implants adjacent to the dental roots and maxillary sinuses.

  2. Scala tympani cochleostomy I: results of a survey.

    PubMed

    Adunka, Oliver F; Buchman, Craig A

    2007-12-01

    To assess current surgical techniques for scala tympani cochlear implantation among North American surgeons. A survey was distributed to all cochlear implant surgeons participating in the 2006 William House Cochlear Implant Study Group in Toronto, Canada. Participants were asked to anonymously identify their routine surgical practices. Images of trans-facial recess approaches to the round window and cochlear promontory were used in a multiple-choice fashion to assess the surgeon's typical exposure and cochleostomy location. Returned questionnaires were electronically processed and evaluated. Fifty-five (75%) of 73 returned surveys had adequate data validity and availability. Landmark identification and preferred cochleostomy locations varied greatly. About 20% of surgeons selected cochleostomy locations superior to the round window membrane. Cochleostomy size and location appeared to be influenced by surgical experience and whether or not the round window overhang was drilled off. This survey clearly documents marked variations in surgical techniques for scala tympani cochlear implantation. Future studies should more clearly define the surgical anatomy of this region for appropriate placement of a scala tympani cochleostomy. These findings may ultimately have an impact on hearing and neural preservation cochlear implant surgeries.

  3. Essential Tremor

    MedlinePlus

    ... individuals. Deep brain stimulation uses a surgically implanted, battery-operated medical device called a neurostimulator to delivery ... individuals. Deep brain stimulation uses a surgically implanted, battery-operated medical device called a neurostimulator to delivery ...

  4. Accuracy Evaluation of a Stereolithographic Surgical Template for Dental Implant Insertion Using 3D Superimposition Protocol.

    PubMed

    Cristache, Corina Marilena; Gurbanescu, Silviu

    2017-01-01

    of this study was to evaluate the accuracy of a stereolithographic template, with sleeve structure incorporated into the design, for computer-guided dental implant insertion in partially edentulous patients. Sixty-five implants were placed in twenty-five consecutive patients with a stereolithographic surgical template. After surgery, digital impression was taken and 3D inaccuracy of implants position at entry point, apex, and angle deviation was measured using an inspection tool software. Mann-Whitney U test was used to compare accuracy between maxillary and mandibular surgical guides. A p value < .05 was considered significant. Mean (and standard deviation) of 3D error at the entry point was 0.798 mm (±0.52), at the implant apex it was 1.17 mm (±0.63), and mean angular deviation was 2.34 (±0.85). A statistically significant reduced 3D error was observed at entry point p = .037, at implant apex p = .008, and also in angular deviation p = .030 in mandible when comparing to maxilla. The surgical template used has proved high accuracy for implant insertion. Within the limitations of the present study, the protocol for comparing a digital file (treatment plan) with postinsertion digital impression may be considered a useful procedure for assessing surgical template accuracy, avoiding radiation exposure, during postoperative CBCT scanning.

  5. Virtual surgical planning and 3D printing in prosthetic orbital reconstruction with percutaneous implants: a technical case report

    PubMed Central

    Huang, Yu-Hui; Seelaus, Rosemary; Zhao, Linping; Patel, Pravin K; Cohen, Mimis

    2016-01-01

    Osseointegrated titanium implants to the cranial skeleton for retention of facial prostheses have proven to be a reliable replacement for adhesive systems. However, improper placement of the implants can jeopardize prosthetic outcomes, and long-term success of an implant-retained prosthesis. Three-dimensional (3D) computer imaging, virtual planning, and 3D printing have become accepted components of the preoperative planning and design phase of treatment. Computer-aided design and computer-assisted manufacture that employ cone-beam computed tomography data offer benefits to patient treatment by contributing to greater predictability and improved treatment efficiencies with more reliable outcomes in surgical and prosthetic reconstruction. 3D printing enables transfer of the virtual surgical plan to the operating room by fabrication of surgical guides. Previous studies have shown that accuracy improves considerably with guided implantation when compared to conventional template or freehand implant placement. This clinical case report demonstrates the use of a 3D technological pathway for preoperative virtual planning through prosthesis fabrication, utilizing 3D printing, for a patient with an acquired orbital defect that was restored with an implant-retained silicone orbital prosthesis. PMID:27843356

  6. Virtual surgical planning and 3D printing in prosthetic orbital reconstruction with percutaneous implants: a technical case report.

    PubMed

    Huang, Yu-Hui; Seelaus, Rosemary; Zhao, Linping; Patel, Pravin K; Cohen, Mimis

    2016-01-01

    Osseointegrated titanium implants to the cranial skeleton for retention of facial prostheses have proven to be a reliable replacement for adhesive systems. However, improper placement of the implants can jeopardize prosthetic outcomes, and long-term success of an implant-retained prosthesis. Three-dimensional (3D) computer imaging, virtual planning, and 3D printing have become accepted components of the preoperative planning and design phase of treatment. Computer-aided design and computer-assisted manufacture that employ cone-beam computed tomography data offer benefits to patient treatment by contributing to greater predictability and improved treatment efficiencies with more reliable outcomes in surgical and prosthetic reconstruction. 3D printing enables transfer of the virtual surgical plan to the operating room by fabrication of surgical guides. Previous studies have shown that accuracy improves considerably with guided implantation when compared to conventional template or freehand implant placement. This clinical case report demonstrates the use of a 3D technological pathway for preoperative virtual planning through prosthesis fabrication, utilizing 3D printing, for a patient with an acquired orbital defect that was restored with an implant-retained silicone orbital prosthesis.

  7. Electromagnetic interference caused by common surgical energy-based devices on an implanted cardiac defibrillator.

    PubMed

    Paniccia, Alessandro; Rozner, Marc; Jones, Edward L; Townsend, Nicole T; Varosy, Paul D; Dunning, James E; Girard, Guillaume; Weyer, Christopher; Stiegmann, Gregory V; Robinson, Thomas N

    2014-12-01

    Surgical energy-based devices emit energy, which can interfere with other electronic devices (eg, implanted cardiac pacemakers and/or defibrillators). The purpose of this study was to quantify the amount of unintentional energy (electromagnetic interference [EMI]) transferred to an implanted cardiac defibrillator by common surgical energy-based devices. A transvenous cardiac defibrillator was implanted in an anesthetized pig. The primary outcome measure was the average maximum EMI occurring on the implanted cardiac device during activations of multiple different surgical energy-based devices. The EMI transferred to the implanted cardiac device is as follows: traditional bipolar 30 W .01 ± .004 mV, advanced bipolar .004 ± .003 mV, ultrasonic shears .01 ± .004 mV, monopolar Bovie 30 W coagulation .50 ± .20 mV, monopolar Bovie 30 W blend .92 ± .63 mV, monopolar instrument without dispersive electrode .21 ± .07 mV, plasma energy 3.48 ± .78 mV, and argon beam coagulator 2.58 ± .34 mV. Surgeons can minimize EMI on implanted cardiac defibrillators by preferentially utilizing bipolar and ultrasonic devices. Copyright © 2014 Elsevier Inc. All rights reserved.

  8. Micro CT and human histological analysis of a peri-implant osseous defect grafted with porous titanium granules: a case report.

    PubMed

    Wohlfahrt, Johan Caspar; Aass, Anne Merete; Ronold, Hans Jacob; Lyngstadaas, Stale Petter

    2011-01-01

    Treatment of peri-implant osseous defects represents a significant challenge for clinicians, and the need to evolve within predictable surgical procedures is important. This case report describes the surgical treatment and grafting with porous titanium granules (PTG) of one patient with a peri-implant osseous defect. The suggested thrombogenic properties of titanium are intriguing from the perspective of osseous reconstructive surgery. In an ongoing randomized clinical trial using PTG for treatment of peri-implant osseous defects, one patient with one test implant was excluded and scheduled for implant removal. The surgical therapy included open flap debridement with surface decontamination with 24% EDTA gel, grafting with PTG, and resubmersion of the implant. After 12 months of healing, the implant with surrounding tissues was excised en bloc and micro CT and histological analyses were performed. Analyses showed PTG in close contact with new bone and with bone growing both into the porosities of the graft material and onto the adjacent implant surface. Element analysis demonstrated calcium and phosphorus in the new tissue embedding the PTG and the implant. Int J Oral Maxillofac Implants 2011;26:e9-e14.

  9. Training needs for general dentistry residents to place and restore two-implant-retained mandibular overdentures.

    PubMed

    Malmstrom, Hans; Xiao, Jin; Romanos, Georgios E; Ren, Yan-Fang

    2015-01-01

    Implant therapy is rapidly becoming a standard of care for replacing missing dentition. Predoctoral dental curricula include some training in the implant restorative phase but offer limited exposure to the surgical phase, so it is important for postdoctoral general dentistry residency programs to provide competency training in all phases of implant therapy. The aim of this study was to determine the training needed for general dentistry residents to achieve competence in this area, specifically by defining the number of clinical experiences necessary in both the surgical and prosthetic phases of implant-retained mandibular overdenture construction (IRMOD). Fifteen Advanced Education in General Dentistry (AEGD) residents at one academic dental institution placed two implants in a total of 50 patients with edentulous mandibles and subsequently restored them with IRMOD. The supervising faculty member and the residents evaluated the competency level on a five-point scale after each implant placement and prosthetic case completion. According to the faculty evaluations, the residents achieved surgical competence after placing two implants in four to six cases and prosthetic management competence after restoring two to four cases of IRMOD. All 50 patients were satisfied with the treatment outcomes of IRMOD. This study concluded that general dentistry residents could potentially achieve competence in both the surgical and prosthetic phases of implant therapy while enrolled in an AEGD program.

  10. Simple surgical approach with high-frequency radio-wave electrosurgery for conjunctivochalasis.

    PubMed

    Youm, Dong Ju; Kim, Joon Mo; Choi, Chul Young

    2010-11-01

    To introduce a new simple surgical approach with high-frequency radio-wave electrosurgery to reduce conjunctivochalasis (CCh). Prospective, noncomparative, interventional case series analysis. Twelve patients (20 eyes) with CCh were recruited from the outpatient service of the Department of Ophthalmology, Kangbuk Samsung Hospital, Seoul, Korea. On the inferior bulbar conjunctiva, subconjunctival coagulation was performed with a fine-needle electrode using a high-frequency radio-wave electrosurgical unit (Ellman Surgitron; Ellman International, Inc., Hewlett, NY) in coagulation mode. Conjunctivochalasis grade; epiphora and dry eye symptoms (the Ocular Surface Disease Index [OSDI]; Allergan Inc., Irvine, CA, holds the copyright); and intraoperative and postoperative complications. Eighteen eyes (90%) recovered a smooth, wet, and noninflamed conjunctival surface within 1 month and remained stable for a follow-up period of 3 months. At 3 months postoperatively, 18 eyes (90%) had grade 0 CCh. There was a statistically significant decrease of the OSDI score at 3 months postoperatively (P < 0.001). A surgical approach with high-frequency radio-wave electrosurgery produced a significant reduction in CCh and an improvement in symptoms. Radio-wave surgical techniques represent a favorable alternative to surgical treatment of CCh. The author(s) have no proprietary or commercial interest in any materials discussed in this article. Copyright © 2010 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  11. Hard and soft tissue surgical complications in dental implantology.

    PubMed

    Aziz, Shahid R

    2015-05-01

    This article discusses surgical complications associated with the placement of dental implants, specifically focusing on how they occur (etiology), as well as their management and prevention. Dental implant surgical complications can be classified into those of hard and soft tissues. In general, complications can be avoided with thorough preoperative treatment planning and proper surgical technique. Copyright © 2015 Elsevier Inc. All rights reserved.

  12. Stereoscopic Analysis of Silicone Breast Implant Shells Damaged by Surgical Instruments.

    PubMed

    Rapp, Derek A; Neaman, Keith C; Hammond, Dennis C

    2015-07-01

    Iatrogenic shell injury during the implantation and explantation of silicone gel breast implants may lead to eventual device failure. Identification of the patterns of injury caused by surgical instruments is important when attempting to characterize the cause of shell rupture. Understanding the true causes of device failure may help with its prevention. The purpose of this study was to microscopically characterize patterns of shell injury induced by various surgical instruments. Textured and smooth silicone gel implants were intentionally damaged with a variety of surgical instruments. Various scalpels and surgical scissors ranging in fineness were used to create full-thickness injuries in the implant shell. Optical microscopy and scanning electron microscopy were then used to image the injured area to determine patterns of injury. Full-thickness striations across the thickness of the shell could be seen with damage caused by scissors. The density of these striations correlated directly with the fineness of scissors used. No striations were seen with injuries caused by scalpels. Striations were only observed in injuries caused by scissors and suture needles. Striation density correlated with the coarseness of the cutting edge. No such striations were seen in shells damaged by a scalpel even when the angle of approach was changed. This difference can be of assistance in distinguishing between scissors versus scalpel injury of an implant shell.

  13. Implant decontamination with phosphoric acid during surgical peri-implantitis treatment: a RCT.

    PubMed

    Hentenaar, Diederik F M; De Waal, Yvonne C M; Strooker, Hans; Meijer, Henny J A; Van Winkelhoff, Arie-Jan; Raghoebar, Gerry M

    2017-12-01

    Peri-implantitis is known as an infectious disease that affects the peri-implant soft and hard tissue. Today, scientific literature provides very little evidence for an effective intervention protocol for treatment of peri-implantitis. The aim of the present randomized controlled trial is to evaluate the microbiological and clinical effectiveness of phosphoric acid as a decontaminating agent of the implant surface during surgical peri-implantitis treatment. Peri-implantitis lesions were treated with resective surgical treatment aimed at peri-implant granulation tissue removal, bone recontouring, and pocket elimination. Fifty-three implant surfaces in 28 patients were mechanically cleaned and treated with either 35% phosphoric etching gel (test group) or sterile saline (control group). Microbiological samples were obtained during surgery; clinical parameters were recorded at baseline and at 3 months after treatment. Data were analyzed using multi-variable linear regression analysis and multilevel statistics. Significant immediate reductions in total anaerobic bacterial counts on the implant surface were found in both groups. Immediate reduction was greater when phosphoric acid was used. The difference in log-transformed mean anaerobic counts between both procedures was not statistical significant (p = 0.108), but there were significantly less culture-positive implants after the decontamination procedure in the phosphoric acid group (p = 0.042). At 3 months post-surgery, 75% of the implants in the control group and 63.3% of the implants in the test group showed disease resolution. However, no significant differences in clinical and microbiological outcomes between both groups were found. The application of 35% phosphoric acid after mechanical debridement is superior to mechanical debridement combined with sterile saline rinsing for decontamination of the implant surface during surgical peri-implantitis treatment. However, phosphoric acid as implant surface decontaminant does not seem to enhance clinical outcomes on a 3-month follow-up. Netherlands National Trial Register, NTR5185 (www.trialregister.nl).

  14. Accuracy of implant surgery with surgical guide by inexperienced clinicians: an in vitro study

    PubMed Central

    Tanaka, Hideaki; Sasaki, Masanori; Ichimaru, Eiji; Naito, Yasushi; Matsushita, Yasuyuki; Koyano, Kiyoshi; Nakamura, Seiji

    2015-01-01

    Abstract Implant surgery with surgical guide has been introduced with a concept of position improvement. The surgery might be considered as easy even for inexperienced clinician because of step simplicity. However, there are residual risks, resulting in postoperative complications. The aim of this study was to assess the accuracy of implant surgery with surgical guide by inexperienced clinicians in in vitro. After preoperative computed tomographies (CTs) of five artificial models of unilateral free‐end edentulism with scan templates, five surgical guides were established from templates. Following virtual planning, 10 implants were placed in the 45 and 47 regions by five residents without any placement experiences. All drillings and placements were performed using surgical guides. After postoperative CTs, inaccurate verifications between virtual and actual positions of implants were carried out, by overlaying of pre/postoperative CT data. The angle displacement of implant axis in the 47 region was significantly larger than that in the 45 region (P = 0.031). The 3D offset of implant base in the 47 region was significantly larger than that in the 45 region (P = 0.002). For distal/apical directions, displacements of base in the 47 region were significantly larger than those in the 45 region (P = 0.004 and P = 0.003, respectively). The 3D offset of implant tip in the 47 region was significantly larger than that in the 45 region (P = 0.003). For distal/apical directions, displacements of tip in the 47 region were significantly larger than those in the 45 region (P = 0.002 and P = 0.003, respectively). Within limitations of this in vitro study, data for accuracy of implant surgery with surgical guide would be informative for further studies, because in vitro studies should be substantially made to avoid unnecessary burden of patients, in advance of retro/prospective studies. A comparison of the accuracy in this in vitro model between by inexperienced and well‐experienced operators should be necessary for clinicians intending to use surgical guide for placement. PMID:29744135

  15. Implantation of a 16-channel functional electrical stimulation walking system.

    PubMed

    Sharma, M; Marsolais, E B; Polando, G; Triolo, R J; Davis, J A; Bhadra, N; Uhlir, J P

    1998-02-01

    A 16-channel electrical stimulation system was implanted in a 39-year-old patient with T10 paraplegia to restore sit to stand, walking, and exercise functions. System implantation required two surgical sessions. In the first session, the posterior muscle set consisting of bilateral semimembranosus, adductor magnus, and gluteus maximus muscles were exposed and epimysial electrodes sutured at the point of greatest muscle contraction. Closed double helix intramuscular electrodes were implanted in the erector spinae. Two weeks later, epimysial electrodes were attached to the eight anterior muscles consisting of the tibialis anterior, sartorius, tensor fasciae latae, and vastus lateralis with all 16 electrode leads passed to the anterior abdominal wall. The electrodes were connected to two eight-channel stimulators placed in the iliac fossae, and the system was checked by activating the individual muscles. The implanted stimulators received stimulation instructions and power via a radio frequency link to an external control. Stimulation patterns for standing, walking, sitting, and exercise functions were chosen from a preprogrammed menu via a finger key pad. After 3 weeks of restricted patient activity, all electrodes stimulated either the target muscle or had an acceptable spillover pattern. The patient is undergoing a 16-week rehabilitation course of stimulated exercises gradually increasing in intensity. At the conclusion, the goal is to discharge the patient with the system for spontaneous use. Although long term followup is required to determine system reliability, preliminary clinical results indicate that targeted, repeatable, functional muscle contractions in the lower extremity can be achieved with a system consisting of epimysial electrodes.

  16. Development of Implantable Wireless Sensor Nodes for Animal Husbandry and MedTech Innovation

    PubMed Central

    Lu, Jian; Zhang, Lan; Zhang, Dapeng; Matsumoto, Sohei; Hiroshima, Hiroshi; Maeda, Ryutaro; Sato, Mizuho; Toyoda, Atsushi; Gotoh, Takafumi; Ohkohchi, Nobuhiro

    2018-01-01

    In this paper, we report the development, evaluation, and application of ultra-small low-power wireless sensor nodes for advancing animal husbandry, as well as for innovation of medical technologies. A radio frequency identification (RFID) chip with hybrid interface and neglectable power consumption was introduced to enable switching of ON/OFF and measurement mode after implantation. A wireless power transmission system with a maximum efficiency of 70% and an access distance of up to 5 cm was developed to allow the sensor node to survive for a duration of several weeks from a few minutes’ remote charge. The results of field tests using laboratory mice and a cow indicated the high accuracy of the collected biological data and bio-compatibility of the package. As a result of extensive application of the above technologies, a fully solid wireless pH sensor and a surgical navigation system using artificial magnetic field and a 3D MEMS magnetic sensor are introduced in this paper, and the preliminary experimental results are presented and discussed. PMID:29587448

  17. Computer-assisted template-guided custom-designed 3D-printed implant placement with custom-designed 3D-printed surgical tooling: an in-vitro proof of a novel concept.

    PubMed

    Anssari Moin, David; Derksen, Wiebe; Waars, Hugo; Hassan, Bassam; Wismeijer, Daniel

    2017-05-01

    The aim of this study was to introduce a new concept for computer-assisted template-guided placement of a custom 3D-designed/3D-printed implant with congruent custom 3D-designed/3D-printed surgical tooling and to test the feasibility and accuracy of this method in-vitro. One partially edentulous human mandibular cadaver was scanned with a cone-beam computed tomography (CBCT) system and intra-oral scan system. The 3D data of this cadaver were imported in specialized software and used to analyse the region of a missing tooth. Based on the functional and anatomical parameters, an individual implant with congruent surgical tooling and surgical guided template was designed and 3D-printed. The guided osteotomy was performed, and the custom implant inserted. To evaluate the planned implant position in comparison with the placed implant position, the mandible with implant was scanned again with the CBCT system and software matching was applied to measure the accuracy of the procedure. The angular deflection with the planned implant position was 0.40°. When comparing the 3D positions of the shoulder, there is a deviation of 0.72 mm resulting in an apical deviation of 0.72 mm. With the use of currently available technology, it is very well feasible to create in a virtual simulation a custom implant with congruent custom surgical tooling and to transfer this to a clinical setting. However, further research on multiple levels is needed to explore this novel approach. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  18. A Retrospective Multicentre Cohort Review of Patient Characteristics and Surgical Aspects versus the Long-Term Outcomes for Recipients of a Fully Implantable Active Middle Ear Implant

    PubMed Central

    Lefebvre, Philippe P.; Gisbert, Javier; Cuda, Domenico; Tringali, Stéphane; Deveze, Arnaud

    2017-01-01

    Objective To summarise treatment outcomes compared to surgical and patient variables for a multicentre recipient cohort using a fully implantable active middle ear implant for hearing impairment. To describe the authors' preferred surgical technique to determine microphone placement. Study Design Multicentre retrospective, observational survey. Setting Five tertiary referral centres. Patients Carina recipients (66 ears, 62 subjects) using the current Cochlear® Carina® System or the legacy device, the Otologics® Fully Implantable Middle Ear, with a T2 transducer. Methods Patient file review and routine clinical review. Patient outcomes assessed were satisfaction, daily use and feedback reports at the first fitting and ≥12 months after implantation. Descriptive and statistical analysis of correlations of variables and their influence on outcomes was performed. Independently reported preferred methods for microphone placement are collectively summarised. Results The average implant experience was 3.5 years. Satisfaction increased significantly over time (p < 0.05). No correlation with covariates examined was observed. Feedback significantly decreased over time, showing a significant correlation with microphone location, primary motivation, gender, age at implantation, and contralateral hearing aid use (p < 0.05). Patient satisfaction was inversely correlated with reports of system feedback (p < 0.05). The implantable microphone was most commonly on the posterior inferior mastoid line, in 42/66 (65%) cases, correlating with less likelihood for feedback and consistent with author surgical preference. Conclusion Carina recipients in this study present as satisfied consistent daily users with very few reports of persistent feedback. As microphone location is an influencing factor, a careful surgical consideration of microphone placement is required. The authors prefer a posterior inferior mastoid line position whenever possible. PMID:28052264

  19. Surgical accuracy with the mini-subvastus total knee arthroplasty a computer tomography scan analysis of postoperative implant alignment.

    PubMed

    Schroer, William C; Diesfeld, Paul J; Reedy, Mary E; Lemarr, Angela R

    2008-06-01

    A total of 50 total knee arthroplasty (TKA) patients, 25 traditional and 25 minimally invasive surgical (MIS), underwent computed tomography scans to determine if a loss of accuracy in implant alignment occurred when a surgeon switched from a traditional medial parapatellar arthrotomy to a mini-subvastus surgical technique. Surgical accuracy was determined by comparing the computed tomography measured implant alignment with the surgical alignment goals. There was no loss in accuracy in the implantation of the tibial component with the mini-subvastus technique. The mean variance for the tibial coronal alignment was 1.03 degrees for the traditional TKA and 1.00 degrees for the MIS TKA (P = .183). Similarly, there was no difference in the mean variance for the posterior tibial slope (P = .054). Femoral coronal alignment was less accurate with the MIS procedure, mean variance of 1.04 degrees and 1.71 degrees for the traditional and MIS TKA, respectively (P = .045). Instrumentation and surgical technique concerns that led to this loss in accuracy were determined.

  20. Guided Immediate Implant Placement with Wound Closure by Computer-Aided Design/Computer-Assisted Manufacture Sealing Socket Abutment: Case Report.

    PubMed

    Finelle, Gary; Lee, Sang J

    Digital technology has been widely used in the field of implant dentistry. From a surgical standpoint, computer-guided surgery can be utilized to enhance primary implant stability and to improve the precision of implant placement. From a prosthetic standpoint, computer-aided design/computer-assisted manufacture (CAD/CAM) technology has brought about various restorative options, including the fabrication of customized abutments through a virtual design based on computer-guided surgical planning. This case report describes a novel technique combining the use of a three-dimensional (3D) printed surgical template for the immediate placement of an implant, with CAD/CAM technology to optimize hard and soft tissue healing after bone grafting with the use of a socket sealing abutment.

  1. Preventing and Treating Peri-Implantitis: A Cost-Effectiveness Analysis.

    PubMed

    Schwendicke, Falk; Tu, Yu-Kang; Stolpe, Michael

    2015-09-01

    A large number of treatments for peri-implantitis are available, but their cost-effectiveness remains uncertain. This study evaluates the cost-effectiveness of preventing and treating peri-implantitis. A Markov model was constructed that followed each implant over 20 years. Supportive implant therapy (SIT) for managing peri-implant mucositis and preventing development of peri-implantitis was either provided or not. Risk of peri-implantitis was assumed to be affected by SIT and the patient's risk profile. If peri-implantitis occurred, 11 treatment strategies (non-surgical or surgical debridement alone or combined with adjunct therapies) were compared. Treatments and risk profiles determined disease progression. Modeling was performed based on systematically collected data. Primary outcomes were costs and proportion of lost implants, as assessed via Monte Carlo microsimulations. Not providing SIT and performing only non-surgical debridement was both least costly and least effective. The next best (more costly and effective) option was to provide SIT and perform surgical debridement (additional 0.89 euros per 1% fewer implants lost). The most effective option included bone grafts, membranes, and laser treatment (56 euros per 1%). For patients at high risk, the cost-effectiveness of SIT increased, whereas in low-risk groups, a cost-optimized strategy was cost-effective. Although clinical decision-making will be guided mainly by clinical condition, cost-effectiveness analyses might add another perspective. Based on these findings, an unambiguous comparative effectiveness ranking was not established. However, cost-effectiveness was predominantly determined by provision of SIT and initial treatment costs. Transferability of these findings to other healthcare systems needs further confirmation.

  2. [Contribution of computer-aided design for the conception of custom-made implants in Pectus Excavatum surgical treatment. Experience of the Nantes plastic surgery unit].

    PubMed

    Tilliet Le Dentu, H; Lancien, U; Sellal, O; Duteille, F; Perrot, P

    2018-02-01

    Pectus excavatum is the most common congenital chest malformation and is a common reason for consultation in plastic surgery. Our attitude is most often a filling of the depression with a custom-made silicone prosthesis. The objective of this work was to evaluate the interest of computer-aided design (CAD) of implants compared to the conventional plaster molds method. We have collected all the cases of custom-made silicone implants to treat funnel chests in our plastic surgery department. The quality of the results was evaluated by the patient, and in a blind manner by the surgical team using photographs and standardized surveys. The pre-operative delays, the operating time and length of hospital stays, the number of surgical recoveries, and the post-operative surgical outcomes were recorded. Between 1990 and 2016, we designed 29 silicone thoracic implants in our department. Before 2012, implants were made from plaster chest molds (n=13). After this date, implants were designed by CAD (n=16). Patients rated their results as "good" or "excellent" in 77% and 86% of cases respectively in the plaster and CAD groups. The surgical team's ratings for CAD implant reconstructions were better than in the plaster group: 8.17 versus 6.96 (P=0.001). CAD implants were significantly less detectable than the plaster group implants. The operating time was reduced in the CAO group: 60.2 compared to 74.7minutes in the plaster group (P=0.04), as was the length of hospitalization: 3.5 versus 5.3 days (P=0.01). There were no significant differences between the two groups in terms of post-operative complications. The management of pectus excavatum by a custom-made silicone implant is a minimally invasive method that provides good cosmetic results. The design of these implants is facilitated and qualitatively improved by CAD. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  3. Disaster Victim Identification using Orthopedic Implants in the 2011 East-Japan Earthquake and Tsunami.

    PubMed

    Numata, Norio; Makinae, Haruka; Yoshida, Wataru; Daimon, Masao; Murakami, Hideki

    2017-03-01

    On March 11, 2011, an earthquake (magnitude 9.0) devastated Japan's east coast, and the associated tsunami resulted in social and mechanical destruction. Search for the missing people is still ongoing. Surgical implants are common in the general population. Medical implants usually have lot numbers, and their forensic use is common for victim identification. This investigation was conducted mainly in the cities of Kamaishi and Otsuchi, both of which were affected by the tsunami disaster in 2011. We visited 6 mortuaries with the police between March 20 (9 days after the tsunami) and April 20 (40 days after the tsunami) to examine the presence of surgical scars and related information. Unidentified human remains were investigated by visual and tactile examination. We also visited temples where the ashes were preserved. If implants were found, their lot numbers and estimated surgical procedures were recorded to determine positive identification. Ten of 233 sets of unidentified human remains before cremation displayed characteristics of a potential past surgical history. However, only 2 of these 233 sets had orthopedic implants. Instead, non-combustible orthopedic implants were found and recognized in 8 of the 331 sets of unidentified human ashes in the temples after cremation; the lot numbers were fully legible in 2 of the 8 sets. We estimated the surgical procedures, which led to positive identification. In conclusion, lot numbers and the surgical knowledge of orthopedic surgeons could assist with the positive identification of disaster victims. However, the relevant information can be erased after cremation.

  4. Comparison of patient-specific instruments with standard surgical instruments in determining glenoid component position: a randomized prospective clinical trial.

    PubMed

    Hendel, Michael D; Bryan, Jason A; Barsoum, Wael K; Rodriguez, Eric J; Brems, John J; Evans, Peter J; Iannotti, Joseph P

    2012-12-05

    Glenoid component malposition for anatomic shoulder replacement may result in complications. The purpose of this study was to define the efficacy of a new surgical method to place the glenoid component. Thirty-one patients were randomized for glenoid component placement with use of either novel three-dimensional computed tomographic scan planning software combined with patient-specific instrumentation (the glenoid positioning system group), or conventional computed tomographic scan, preoperative planning, and surgical technique, utilizing instruments provided by the implant manufacturer (the standard surgical group). The desired position of the component was determined preoperatively. Postoperatively, a computed tomographic scan was used to define and compare the actual implant location with the preoperative plan. In the standard surgical group, the average preoperative glenoid retroversion was -11.3° (range, -39° to 17°). In the glenoid positioning system group, the average glenoid retroversion was -14.8° (range, -27° to 7°). When the standard surgical group was compared with the glenoid positioning system group, patient-specific instrumentation technology significantly decreased (p < 0.05) the average deviation of implant position for inclination and medial-lateral offset. Overall, the average deviation in version was 6.9° in the standard surgical group and 4.3° in the glenoid positioning system group. The average deviation in inclination was 11.6° in the standard surgical group and 2.9° in the glenoid positioning system group. The greatest benefit of patient-specific instrumentation was observed in patients with retroversion in excess of 16°; the average deviation was 10° in the standard surgical group and 1.2° in the glenoid positioning system group (p < 0.001). Preoperative planning and patient-specific instrumentation use resulted in a significant improvement in the selection and use of the optimal type of implant and a significant reduction in the frequency of malpositioned glenoid implants. Novel three-dimensional preoperative planning, coupled with patient and implant-specific instrumentation, allows the surgeon to better define the preoperative pathology, select the optimal implant design and location, and then accurately execute the plan at the time of surgery.

  5. 47 CFR 2.1204 - Import conditions.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... generations of a particular model under development are considered to be separate devices. (4) The radio... particular model under development are considered to be separate devices. (5) The radio frequency device is... offered for sale or marketed. (9) The radio frequency device is a medical implant transmitter inserted in...

  6. 47 CFR 2.1204 - Import conditions.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... generations of a particular model under development are considered to be separate devices. (4) The radio... particular model under development are considered to be separate devices. (5) The radio frequency device is... offered for sale or marketed. (9) The radio frequency device is a medical implant transmitter inserted in...

  7. Basic concepts and techniques of dental implants.

    PubMed

    Tagliareni, Jonathan M; Clarkson, Earl

    2015-04-01

    Dental implants provide completely edentulous and partial edentulous patients the function and esthetics they had with natural dentition. It is critical to understand and apply predictable surgical principles when treatment planning and surgically restoring edentulous spaces with implants. This article defines basic implant concepts that should be meticulously followed for predictable results when treating patients and restoring dental implants. Topics include biological and functional considerations, biomechanical considerations, preoperative assessments, medical history and risk assessments, oral examinations, radiographic examinations, contraindications, and general treatment planning options. Copyright © 2015 Elsevier Inc. All rights reserved.

  8. Stratification of risk to the surgical team in removal of small arms ammunition implanted in the craniofacial region: case report.

    PubMed

    Forbes, Jonathan A; Laughlin, Ian; Newberry, Shane; Ryhn, Michael; Pasley, Jason; Newberry, Travis

    2016-09-01

    In cases of penetrating injury with implantation of small arms ammunition, it can often be difficult to tell the difference between simple ballistics and ballistics associated with unexploded ordnances (UXOs). In the operative environment, where highly flammable substances are often close to the surgical site, detonation of UXOs could have catastrophic consequences for both the patient and surgical team. There is a paucity of information in the literature regarding how to evaluate whether an implanted munition contains explosive material. This report describes a patient who presented during Operation Enduring Freedom with an implanted munition suspicious for a UXO and the subsequent workup organized by Explosive Ordnance Disposal (EOD) Company prior to surgical removal. Clinical risk factors for UXOs include assassination attempts and/or wartime settings. Specific radiological features suggestive of a UXO include projectile size greater than 7.62-mm caliber, alterations in density of the tip, as well as radiological evidence of a hollowed-out core. If an implanted UXO is suspected, risks to the surgical and anesthesia teams can be minimized by notifying the nearest military installation with EOD capabilities and following clinical practice guidelines set forth by the Joint Theater Trauma System.

  9. Non-photorealistic rendering of virtual implant models for computer-assisted fluoroscopy-based surgical procedures

    NASA Astrophysics Data System (ADS)

    Zheng, Guoyan

    2007-03-01

    Surgical navigation systems visualize the positions and orientations of surgical instruments and implants as graphical overlays onto a medical image of the operated anatomy on a computer monitor. The orthopaedic surgical navigation systems could be categorized according to the image modalities that are used for the visualization of surgical action. In the so-called CT-based systems or 'surgeon-defined anatomy' based systems, where a 3D volume or surface representation of the operated anatomy could be constructed from the preoperatively acquired tomographic data or through intraoperatively digitized anatomy landmarks, a photorealistic rendering of the surgical action has been identified to greatly improve usability of these navigation systems. However, this may not hold true when the virtual representation of surgical instruments and implants is superimposed onto 2D projection images in a fluoroscopy-based navigation system due to the so-called image occlusion problem. Image occlusion occurs when the field of view of the fluoroscopic image is occupied by the virtual representation of surgical implants or instruments. In these situations, the surgeon may miss part of the image details, even if transparency and/or wire-frame rendering is used. In this paper, we propose to use non-photorealistic rendering to overcome this difficulty. Laboratory testing results on foamed plastic bones during various computer-assisted fluoroscopybased surgical procedures including total hip arthroplasty and long bone fracture reduction and osteosynthesis are shown.

  10. Immediate implants placed into infected sockets: a case report with 3-year follow-up.

    PubMed

    Naves, Marina de Melo; Horbylon, Bruna Zacharias; Gomes, Camila de Freitas; Menezes, Helder Henrique Machado de; Bataglion, César; Magalhães, Denildo de

    2009-01-01

    The esthetics and functional integrity of the periodontal tissue may be compromised by dental loss. Immediate implants became a viable option to maintain the periodontal architecture because of their anatomic compatibility with the dental socket and the possibility of eliminating local contamination. This article describes the procedure of immediate implant placement in the anterior maxilla replacing teeth with chronic periapical lesions, which were condemned due to endodontic lesions persisting after failed endodontic treatment and endodontic surgery, and discusses the relationship between the procedure and periapical lesions. Surgical removal of hopeless teeth 11, 12 and 21 was performed conservatively in such a way to preserve the anatomy and gingival esthetics. A second surgical access was gained at the apical level, allowing the debridement of the surgical chamber for elimination of the periapical lesion, visual orientation for setting of the implants and filling of the surgical chamber with xenogenous bovine bone graft. After this procedure, the bone chamber was covered with an absorbent membrane and the healing screws were positioned on the implants. Later, a provisional partial removable denture was installed and the implants were inserted after 6 months. After 3 years of rehabilitation, the implants present satisfactory functional and esthetic conditions, suggesting that immediate implant placement combined with guided bone regeneration may be indicated for replacing teeth lost due to chronic periapical lesions with endodontic failure history in the anterior maxilla.

  11. Stereolithographic Surgical Template: A Review

    PubMed Central

    Dandekeri, Shilpa Sudesh; Sowmya, M.K.; Bhandary, Shruthi

    2013-01-01

    Implant placement has become a routine modality of dental care.Improvements in surgical reconstructive methods as well as increased prosthetic demands,require a highly accurate diagnosis, planning and placement. Recently,computer-aided design and manufacturing have made it possible to use data from computerised tomography to not only plan implant rehabilitation,but also transfer this information to the surgery.A review on one of this technique called Stereolithography is presented in this article.It permits graphic and complex 3D implant placement and fabrication of stereolithographic surgical templates. Also offers many significant benefits over traditional procedures. PMID:24179955

  12. CAD/CAM guided surgery in implant dentistry. A review of software packages and step-by-step protocols for planning surgical guides.

    PubMed

    Scherer, Michael D; Kattadiyil, Mathew T; Parciak, Ewa; Puri, Shweta

    2014-01-01

    Three-dimensional radiographic imaging for dental implant treatment planning is gaining widespread interest and popularity. However, application of the data from 30 imaging can be a complex and daunting process initially. The purpose of this article is to describe features of three software packages and the respective computerized guided surgical templates (GST) fabricated from them. A step-by-step method of interpreting and ordering a GST to simplify the process of the surgical planning and implant placement is discussed.

  13. A laboratory for life sciences research in space

    NASA Technical Reports Server (NTRS)

    Williams, B. A.; Klein, H. P.

    1982-01-01

    Biological studies hardware for Spacelab flights are described. The research animal holding facility has modular construction and is installed on a single ESA rack. A biotelemetry system will provide body temperature and EKG/heart rate data from a radio transmitter surgically implanted in the animals' stomachs. A plant growth unit (PGU) will be used to study micro-g plant lignin growth. The PGU is automated and can carry as many as 96 plants. A general purpose work station (GPWS) biohazard cabinet will be flown on Spacelab 4 to control liquid and chemical vapors released during experimentation. Spacelab 4 will be the premier flight of actual animal studies comprising measurements of hematology, muscle biochemistry, blood circulation, fluids and electrolytes, vestibular adaptation, etc., using rats and squirrel monkeys as subjects.

  14. Cranial reconstruction: 3D biomodel and custom-built implant created using additive manufacturing.

    PubMed

    Jardini, André Luiz; Larosa, Maria Aparecida; Maciel Filho, Rubens; Zavaglia, Cecília Amélia de Carvalho; Bernardes, Luis Fernando; Lambert, Carlos Salles; Calderoni, Davi Reis; Kharmandayan, Paulo

    2014-12-01

    Additive manufacturing (AM) technology from engineering has helped to achieve several advances in the medical field, particularly as far as fabrication of implants is concerned. The use of AM has made it possible to carry out surgical planning and simulation using a three-dimensional physical model which accurately represents the patient's anatomy. AM technology enables the production of models and implants directly from a 3D virtual model, facilitating surgical procedures and reducing risks. Furthermore, AM has been used to produce implants designed for individual patients in areas of medicine such as craniomaxillofacial surgery, with optimal size, shape and mechanical properties. This work presents AM technologies which were applied to design and fabricate a biomodel and customized implant for the surgical reconstruction of a large cranial defect. A series of computed tomography data was obtained and software was used to extract the cranial geometry. The protocol presented was used to create an anatomic biomodel of the bone defect for surgical planning and, finally, the design and manufacture of the patient-specific implant. Copyright © 2014 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  15. Magnetic resonance imaging metallic artifact of commonly encountered surgical implants and foreign material.

    PubMed

    Sutherland-Smith, James; Tilley, Brenda

    2012-01-01

    Magnetic resonance imaging (MRI) artifacts secondary to metallic implants and foreign bodies are well described. Herein, we provide quantitative data from veterinary implants including total hip arthroplasty implants, cranial cruciate repair implants, surgical screws, a skin staple, ligation clips, an identification microchip, ameroid constrictor, and potential foreign bodies including air gun and BB projectiles and a sewing needle. The objects were scanned in a gelatin phantom with plastic grid using standardized T2-weighted turbo-spin echo (TSE), T1-weighted spin echo, and T2*-weighted gradient recalled echo (GRE) image acquisitions at 1.5 T. Maximum linear dimensions and areas of signal voiding and grid distortion were calculated using a DICOM workstation for each sequence and object. Artifact severity was similar between the T2-weighted TSE and T1-weighted images, while the T2*-weighted images were most susceptible to artifact. Metal type influenced artifact size with the largest artifacts arising from steel objects followed by surgical stainless steel, titanium, and lead. For animals with metallic surgical implants or foreign bodies, the quantification of the artifact size will help guide clinicians on the viability of MRI. © 2012 Veterinary Radiology & Ultrasound.

  16. Retrospective Analysis on Survival Rate, Template-Related Complications, and Prevalence of Peri-implantitis of 694 Anodized Implants Placed Using Computer-Guided Surgery: Results Between 1 and 10 Years of Follow-Up.

    PubMed

    Tallarico, Marco; Meloni, Silvio Mario

    To report survival rate, early surgical template-related complications, and prevalence of peri-implantitis of dental implants placed in private practices using computer-guided, template-assisted surgery and followed between 1 and 10 years. The present retrospective multicenter study evaluated data collected from fully or partially edentulous patients, with anodized-surface implants placed using computer-guided, template-assisted surgery between January 2006 and December 2015. The outcome measures were implant cumulative survival rate (CSR), early surgical complications involving the surgical template, and prevalence of peri-implantitis. A total of 694 implants were placed in 141 patients. Ten patients (7.1%) with 48 implants (6.9%) dropped out during the study period. One hundred seventeen patients, who received 121 surgical and prosthetic procedures, were treated according to a double-scan protocol, while the remaining 24 patients were treated by using the integrated treatment workflow. Most of the implants were immediately loaded (528 implants, 76.1%; 112 patients, 79.4%). Overall, 107 complete full-arch restorations (supported by four to eight implants each) were delivered in 103 patients (73%) with 595 implants (85.7%), while 13 single and 30 partial restorations (two to five implants each) were delivered in 38 patients (27%) with 99 implants (14.3%). Patients were followed for up to 10 years (mean: 58.2 months, range: 12 to 120 months). Implant- and patient-level CSR (Kaplan-Meier estimation) at the 10-year follow-up was 97.4% (95% CI: 1.0309 to 0.9161) and 92.1% (95% CI: 1.1575 to 0.6836), respectively. All failed implants were lost before definitive prosthesis delivery (early failure). Ten (7.1%) minor template-related complications were experienced and resolved chairside. Over the entire follow-up period, four patients (2.8%) with 12 implants (1.7%) showed signs of peri-implantitis at the 1- (four implants), 2- (four implants), and 4-year (four implants) visits. High long-term survival rates and low complications and prevalence of peri-implantitis were observed for a large cohort of anodized-surface implants placed in private practices. Further studies are needed to confirm these preliminary results.

  17. In vitro evaluation of a passive radio frequency identification microchip implanted in human molars subjected to compression forces, for forensic purposes of human identification

    PubMed Central

    Moreno, Freddy; Vallejo, Diego; Garzón, Herney; Moreno, Sandra

    2013-01-01

    Objective: To evaluate the in vitro behavior of a passive Radio Frequency Identification (RFID) microchip implanted in human molars subjected to compression forces to determine its technical and clinical viability. Materials and Methods: In vitro experimental study to evaluate the physical behavior of a passive RFID microchip (VeriChip™) implanted in human molars through resin restoration (Filtek P90™ Silorane 3M-ESPE®) to determine the clinical and technical possibilities of the implant and the viability to withstand compression forces exerted by the stomatognathic system during mastication. Results: Through the ANOVA test, it was found that the teeth on which a microchip was implanted show great resistance to compressive forces. It was also evident that teeth with microchips implanted in Class V cavities are more resistant than those implanted in Class I cavities. Conclusions: Although microchip dimensions are big, requiring a sufficiently large cavity, from the biomechanical point of view it is plausible to implant a microchip in a Class V cavity employing restoration material based on resin for forensic purposes of human identification. PMID:24255554

  18. Surgical meshes coated with mesenchymal stem cells provide an anti-inflammatory environment by a M2 macrophage polarization.

    PubMed

    Blázquez, Rebeca; Sánchez-Margallo, Francisco Miguel; Álvarez, Verónica; Usón, Alejandra; Casado, Javier G

    2016-02-01

    Surgical meshes are widely used in clinics to reinforce soft tissue's defects, and to give support to prolapsed organs. However, the implantation of surgical meshes is commonly related with an inflammatory response being difficult to eradicate without removing the mesh. Here we hypothesize that the combined use of surgical meshes and mesenchymal stem cells (MSCs) could be a useful tool to reduce the inflammatory reaction secondary to mesh implantation. In vitro determinations of viability, metabolic activity and immunomodulation assays were performed on MSCs-coated meshes. Magnetic resonance imaging, evaluation by laparoscopic optical system and histology were performed for safety assessment. Finally, flow cytometry and qRT-PCR were used to elucidate the mechanism of action of MSCs-coated meshes. Our results demonstrate the feasibility to obtain MSCs-coated surgical meshes and their cryopreservability to be used as an 'off the shelf' product. These biological meshes fulfill the safety aspects as non-adverse effects were observed when compared to controls. Moreover, both in vitro and in vivo studies demonstrated that, local immunomodulation of implanted meshes is mediated by a macrophage polarization towards an anti-inflammatory phenotype. In conclusion, the combined usage of surgical meshes with MSCs fulfills the safety requirements for a future clinical application, providing an anti-inflammatory environment that could reduce the inflammatory processes commonly observed after surgical mesh implantation. Surgical meshes are medical devices widely used in clinics to resolve hernias and organs' prolapses, among other disorders. However, the implantation of surgical meshes is commonly related with an inflammatory response being difficult to eradicate without removing the mesh, causing pain and discomfort in the patient. Previously, the anti-inflammatory, immunomodulatory and pro-regenerative ability of mesenchymal stem cells (MSCs) have been described. To our knowledge, this is the first report where the anti-inflammatory and pro-regenerative ability of MSCs have been successfully applied in combination with surgical meshes, reducing the inflammatory processes commonly observed after mesh implantation. Moreover, our in vitro and in vivo results highlight the safety and efficacy of these bioactive meshes as a 'ready to use' medical product. Copyright © 2015 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  19. A cost-utility analysis of transcatheter versus surgical aortic valve replacement for the treatment of aortic stenosis in the population with intermediate surgical risk.

    PubMed

    Tam, Derrick Y; Hughes, Avery; Fremes, Stephen E; Youn, Saerom; Hancock-Howard, Rebecca L; Coyte, Peter C; Wijeysundera, Harindra C

    2018-05-01

    Although transcatheter aortic valve implantation has been shown to be noninferior to surgical aortic valve replacement in patients with severe aortic stenosis at intermediate surgical risk, the cost-effectiveness of this strategy in this population is unknown. Our objective was to conduct a cost-utility analysis comparing transcatheter aortic valve implantation with surgical aortic valve replacement in the population with intermediate risk severe aortic stenosis. A fully probabilistic Markov model with 30-day cycles was constructed from the Canadian third-party payer's perspective to estimate the difference in cost and effectiveness (measured as quality-adjusted life years) of transcatheter aortic valve implantation versus surgical aortic valve replacement for intermediate-risk patients over a lifetime time horizon, discounted at 1.5% per annum. Clinical trial data from The Placement of Aortic Transcatheter Valve 2 informed the efficacy inputs. Costs (adjusted to 2016 Canadian dollars) were obtained from the Canadian Institute of Health Information and the Ontario Schedule of Benefits. Incremental cost-effectiveness ratios were calculated. In the base-case analysis, total lifetime costs for transcatheter aortic valve implantation were $10,548 higher than surgical aortic valve replacement but added 0.23 quality-adjusted life years, for an incremental cost-effectiveness ratio of $46,083/quality-adjusted life-years gained. Deterministic 1-way analyses showed that the incremental cost-effectiveness ratio was sensitive to rates of complications and cost of the transcatheter aortic valve implantation prosthesis. There was moderate-to-high parameter uncertainty; transcatheter aortic valve implantation was the preferred option in only 52.7% and 55.4% of the simulations at a $50,000 and $100,000 per quality-adjusted life years willingness-to-pay thresholds, respectively. On the basis of current evidence, transcatheter aortic valve implantation may be cost-effective for the treatment of severe aortic stenosis in patients with intermediate surgical risk. There remains moderate-to-high uncertainty surrounding the base-case incremental cost-effectiveness ratio. Copyright © 2018 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  20. Customizable cap implants for neurophysiological experimentation.

    PubMed

    Blonde, Jackson D; Roussy, Megan; Luna, Rogelio; Mahmoudian, Borna; Gulli, Roberto A; Barker, Kevin C; Lau, Jonathan C; Martinez-Trujillo, Julio C

    2018-04-22

    Several primate neurophysiology laboratories have adopted acrylic-free, custom-fit cranial implants. These implants are often comprised of titanium or plastic polymers, such as polyether ether ketone (PEEK). Titanium is favored for its mechanical strength and osseointegrative properties whereas PEEK is notable for its lightweight, machinability, and MRI compatibility. Recent titanium/PEEK implants have proven to be effective in minimizing infection and implant failure, thereby prolonging experiments and optimizing the scientific contribution of a single primate. We created novel, customizable PEEK 'cap' implants that contour to the primate's skull. The implants were created using MRI and/or CT data, SolidWorks software and CNC-machining. Three rhesus macaques were implanted with a PEEK cap implant. Head fixation and chronic recordings were successfully performed. Improvements in design and surgical technique solved issues of granulation tissue formation and headpost screw breakage. Primate cranial implants have traditionally been fastened to the skull using acrylic and anchor screws. This technique is prone to skin recession, infection, and implant failure. More recent methods have used imaging data to create custom-fit titanium/PEEK implants with radially extending feet or vertical columns. Compared to our design, these implants are more surgically invasive over time, have less force distribution, and/or do not optimize the utilizable surface area of the skull. Our PEEK cap implants served as an effective and affordable means to perform electrophysiological experimentation while reducing surgical invasiveness, providing increased strength, and optimizing useful surface area. Crown Copyright © 2018. Published by Elsevier B.V. All rights reserved.

  1. Comparison of Lyophilized Glutaraldehyde-Preserved Bovine Pericardium with Different Vascular Prostheses for Use as Vocal Cords Implants: Experimental Study

    PubMed Central

    Olmos-Zuñiga, J. Raúl; Jasso-Victoria, Rogelio; Gaxiola-Gaxiola, Miguel; Sotres-Vega, Avelina; Hernández-Jiménez, Claudia; Baltazares-Lipp, Matilde; Arredondo del Bosque, Fernando; Santillan-Doherty, Patricio

    2015-01-01

    This study compared the use of lyophilized glutaraldehyde-preserved bovine pericardium (LGPBP), polytetrafluoroethylene (PTFE), polyethylene terephthalate (PET), and Teflon felt (TF) as implants for vocal cords (VC) medialization and aimed to assess the endoscopic, macroscopic, and microscopic VC changes after medialization in a canine model. In 18 mongrel dogs, the right VC were medialized with LGPBP and the left were implanted as follows: Group I (n = 6): LGPBP and PTFE; Group II (n = 6): LGPBP and PET; Group III (n = 6): LGPBP and TF. Surgical handling of the implants was compared. Three months after surgery, macroscopic and microscopic changes of VC and implants were evaluated. LGPBP offered the best surgical handling (p = 0.005, Kruskal-Wallis). TF implants showed extrusion (p = 0.005, Kruskal-Wallis) and severe inflammation. All VC formed fibrous capsules around the implants; the ones developed by LGPBP implants were thinner (p = 0.001, ANOVA, Tukey). VC implanted with synthetic materials showed eosinophilic infiltration (p = 0.01, Kruskal-Wallis). We concluded that the LGPBP could be used as an implant for VC medialization because it is biocompatible, easy to handle and remove during surgical procedures, and nonabsorbable or extrudable and produces an inflammatory reaction similar to PTFE and PET. PMID:26075232

  2. Comparison of lyophilized glutaraldehyde-preserved bovine pericardium with different vascular prostheses for use as vocal cords implants: experimental study.

    PubMed

    Olmos-Zuñiga, J Raúl; Jasso-Victoria, Rogelio; Gaxiola-Gaxiola, Miguel; Sotres-Vega, Avelina; Hernández-Jiménez, Claudia; Baltazares-Lipp, Matilde; Arredondo del Bosque, Fernando; Santillan-Doherty, Patricio

    2015-01-01

    This study compared the use of lyophilized glutaraldehyde-preserved bovine pericardium (LGPBP), polytetrafluoroethylene (PTFE), polyethylene terephthalate (PET), and Teflon felt (TF) as implants for vocal cords (VC) medialization and aimed to assess the endoscopic, macroscopic, and microscopic VC changes after medialization in a canine model. In 18 mongrel dogs, the right VC were medialized with LGPBP and the left were implanted as follows: Group I (n = 6): LGPBP and PTFE; Group II (n = 6): LGPBP and PET; Group III (n = 6): LGPBP and TF. Surgical handling of the implants was compared. Three months after surgery, macroscopic and microscopic changes of VC and implants were evaluated. LGPBP offered the best surgical handling (p = 0.005, Kruskal-Wallis). TF implants showed extrusion (p = 0.005, Kruskal-Wallis) and severe inflammation. All VC formed fibrous capsules around the implants; the ones developed by LGPBP implants were thinner (p = 0.001, ANOVA, Tukey). VC implanted with synthetic materials showed eosinophilic infiltration (p = 0.01, Kruskal-Wallis). We concluded that the LGPBP could be used as an implant for VC medialization because it is biocompatible, easy to handle and remove during surgical procedures, and nonabsorbable or extrudable and produces an inflammatory reaction similar to PTFE and PET.

  3. Cochlear Implantation After Partial or Subtotal Cochleoectomy for Intracochlear Schwannoma Removal-A Technical Report.

    PubMed

    Plontke, Stefan K; Kösling, Sabrina; Rahne, Torsten

    2018-03-01

    To describe the technique for surgical tumor removal, cochlear implant (CI) electrode placement and reconstruction of the surgical defect in patients with intracochlear schwannomas. Retrospective case review. Tertiary referral center. Ten patients (five men, five women, mean age 48 ± 12 yr) with profound or severe to profound hearing loss due to intralabyrinthine schwannomas with intracochlear location. Surgical tumor removal through extended round window approach, partial or subtotal cochleoectomy with or without labyrinthectomy and reconstruction of the surgical defect with cartilage, perichondrium or temporal muscle fascia, and bone pâté. Eight patients received a cochlear implant in the same procedure. Retrospective evaluation of clinical outcome including safety aspects (adverse events) and audiological performance at early follow up in cases of cochlear implantation. The tumor was successfully removed in all cases without macroscopic (operation microscope and endoscope) tumor remnants in the bony labyrinth apart from one case with initial transmodiolar growth. One patient needed revision surgery for labyrinthine fistula. At short-term follow up (3-month post-surgery), good hearing results with the cochlear implant were obtained in all but one patient with a word recognition score of 100% for numbers, and 64 ± 14% for monosyllables (at 65 dB SPL in quiet). Surgical tumor removal and cochlear implantation is a promising treatment strategy in the management of intralabyrinthine schwannoma with intracochlear location, further extending the indication range for cochlear implantation. It is, however, of importance to observe the long-term outcome in these patients and to address challenges like follow up with magnetic resonance imaging.

  4. Cadaveric feasibility study of da Vinci Si-assisted cochlear implant with augmented visual navigation for otologic surgery.

    PubMed

    Liu, Wen P; Azizian, Mahdi; Sorger, Jonathan; Taylor, Russell H; Reilly, Brian K; Cleary, Kevin; Preciado, Diego

    2014-03-01

    To our knowledge, this is the first reported cadaveric feasibility study of a master-slave-assisted cochlear implant procedure in the otolaryngology-head and neck surgery field using the da Vinci Si system (da Vinci Surgical System; Intuitive Surgical, Inc). We describe the surgical workflow adaptations using a minimally invasive system and image guidance integrating intraoperative cone beam computed tomography through augmented reality. To test the feasibility of da Vinci Si-assisted cochlear implant surgery with augmented reality, with visualization of critical structures and facilitation with precise cochleostomy for electrode insertion. Cadaveric case study of bilateral cochlear implant approaches conducted at Intuitive Surgical Inc, Sunnyvale, California. Bilateral cadaveric mastoidectomies, posterior tympanostomies, and cochleostomies were performed using the da Vinci Si system on a single adult human donor cadaveric specimen. Radiographic confirmation of successful cochleostomies, placement of a phantom cochlear implant wire, and visual confirmation of critical anatomic structures (facial nerve, cochlea, and round window) in augmented stereoendoscopy. With a surgical mean time of 160 minutes per side, complete bilateral cochlear implant procedures were successfully performed with no violation of critical structures, notably the facial nerve, chorda tympani, sigmoid sinus, dura, or ossicles. Augmented reality image overlay of the facial nerve, round window position, and basal turn of the cochlea was precise. Postoperative cone beam computed tomography scans confirmed successful placement of the phantom implant electrode array into the basal turn of the cochlea. To our knowledge, this is the first study in the otolaryngology-head and neck surgery literature examining the use of master-slave-assisted cochleostomy with augmented reality for cochlear implants using the da Vinci Si system. The described system for cochleostomy has the potential to improve the surgeon's confidence, as well as surgical safety, efficiency, and precision by filtering tremor. The integration of augmented reality may be valuable for surgeons dealing with complex cases of congenital anatomic abnormality, for revision cochlear implant with distorted anatomy and poorly pneumatized mastoids, and as a method of interactive teaching. Further research into the cost-benefit ratio of da Vinci Si-assisted otologic surgery, as well as refinements of the proposed workflow, are required before considering clinical studies.

  5. In-Body to On-Body Ultrawideband Propagation Model Derived From Measurements in Living Animals.

    PubMed

    Floor, Pål Anders; Chávez-Santiago, Raúl; Brovoll, Sverre; Aardal, Øyvind; Bergsland, Jacob; Grymyr, Ole-Johannes H N; Halvorsen, Per Steinar; Palomar, Rafael; Plettemeier, Dirk; Hamran, Svein-Erik; Ramstad, Tor A; Balasingham, Ilangko

    2015-05-01

    Ultrawideband (UWB) radio technology for wireless implants has gained significant attention. UWB enables the fabrication of faster and smaller transceivers with ultralow power consumption, which may be integrated into more sophisticated implantable biomedical sensors and actuators. Nevertheless, the large path loss suffered by UWB signals propagating through inhomogeneous layers of biological tissues is a major hindering factor. For the optimal design of implantable transceivers, the accurate characterization of the UWB radio propagation in living biological tissues is indispensable. Channel measurements in phantoms and numerical simulations with digital anatomical models provide good initial insight into the expected path loss in complex propagation media like the human body, but they often fail to capture the effects of blood circulation, respiration, and temperature gradients of a living subject. Therefore, we performed UWB channel measurements within 1-6 GHz on two living porcine subjects because of the anatomical resemblance with an average human torso. We present for the first time, a path loss model derived from these in vivo measurements, which includes the frequency-dependent attenuation. The use of multiple on-body receiving antennas to combat the high propagation losses in implant radio channels was also investigated.

  6. A novel conversion method for radiographic guide into surgical guide.

    PubMed

    Peng, Yao-Te; Tseng, Chung-Chih; Du, Yi-Chun; Chen, Yen-Nien; Chang, Chih-Han

    2017-06-01

    The study proposed a novel method for converting a radiographic guide into a surgical guide and evaluated its accuracy. Radiographic guide was reformed with the addition of index rods for geometric conversion method (GCM). Planning implants were projected on geometric projection planes, and the implant positions were measured. The radiographic guide was converted into surgical guide using a generic bench drill machine with GCM data. Two experiments were designed to validate the GCM. (1) In vitro test: Twenty implants were placed on five edentulous dental models by using the GCM (group 1) and Stereolithography (SLA) method (group 2), respectively. The deviations of planned and placed implant were calculated, and the precision error (PE) value was calculated to evaluate the stability of the GCM and SLA. (2) In vivo test: Nine edentulous subjects were selected for clinical implant surgery with the GCM guide. Two level of the index rods of radiographic guides were prepared for surgical guides forming. The differences between the planned and actual implants were calculated in implant head, apex, and angulation. The in vitro test revealed no significant differences in the planned and placed angulations between groups 1 and 2 (P > .05). The PE was not significantly different between groups 1 and 2 (P > .05). The in vivo test revealed a successful treatment of the subjects, and 16 implant sites were evaluated. The results indicated that GCM guide could achieve the three-dimensional (3D) offset deviations of 1.03 ± 0.27 mm and 1.17 ± 0.24 mm at the implant head and apex, respectively, and 1.37° ± 0.21° for the 3D angulation. The novel method for converting a radiographic guide into a surgical guide appears accurate and stable compared with SLA. © 2017 Wiley Periodicals, Inc.

  7. Poster — Thur Eve — 41: Considerations for Patients with Permanently Implant Radioactive Sources Requiring Unrelated Surgery

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Basran, P. S; Beckham, WA; Baxter, P

    Permanent implant of sealed radioactive sources is an effective technique for treating cancer. Typically, the radioactive sources are implanted in and near the disease, depositing dose locally over several months. There may be instances where these patients must undergo unrelated surgical procedures when the radioactive material remains active enough to pose risks. This work explores these risks, discusses strategies to mitigate those risks, and describes a case study for a permanent I-125 prostate brachytherapy implant patient who developed colo-rectal cancer and required surgery 6 months after brachytherapy. The first consideration is identifying the risk from unwarranted radiation to the patientmore » and staff before, during, and after the surgical procedure. The second is identifying the risk the surgical procedure may have on the efficacy of the brachytherapy implant. Finally, there are considerations for controlling for radioactive substances from a regulatory perspective. After these risks are defined, strategies to mitigate those risks are considered. These strategies may include applying the concepts of ALARA, the use of protective equipment and developing a best practice strategy with the operating room team. We summarize this experience with some guidelines: If the surgical procedure is near (ex: 5 cm) of the implant; and, the surgical intervention may dislodge radioisotopes enough to compromise treatment or introduces radiation safety risks; and, the radioisotope has not sufficiently decayed to background levels; and, the surgery cannot be postponed, then a detailed analysis of risk is advised.« less

  8. Orbital implant placement using a computer-aided design and manufacturing (CAD/CAM) stereolithographic surgical template protocol.

    PubMed

    Goh, B T; Teoh, K H

    2015-05-01

    Surgical implant placement in the orbital region for the support of a prosthesis is challenging due to the thin orbital rim and proximity to vital structures. This article reports the use of a computer-aided design and manufacturing (CAD/CAM) stereolithographic surgical template protocol for orbital implant placement in four patients, who were followed-up for about 7 years. A total of 11 orbital implants were inserted, eight of these in irradiated bone. No intraoperative complications were noted in any of the patients and the implants were all inserted in the planned positions. The survival rate of implants placed in irradiated bone that received hyperbaric oxygen therapy was 62.5% (5/8). One implant failed in a burns injury patient at 74 months after functional loading. The overall survival of implants in the orbital region and the cumulative survival at 7 years was 63.6%. With regard to skin reactions around the abutments, 85% were grade 0, 13% were grade 1, and 2% were grade 2 according to the Holgers classification. The mean survival time of the first prosthesis was 49 months. High patient satisfaction was achieved with the implant-retained orbital prostheses. Copyright © 2014 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  9. Vertical fixation with fibrin glue-assisted secondary posterior chamber intraocular lens implantation in a case of surgical aphakia

    PubMed Central

    Ladi, Jeevan S; Shah, Nitant A

    2013-01-01

    We report the first case of vertical fixation by fibrin glue-assisted secondary posterior chamber intraocular lens implantation in a case of surgical aphakia. Advantages of vertical fixation are discussed. PMID:23514650

  10. The Fyodorov Sputnik intraocular lens.

    PubMed

    Kwitko, M L

    1979-04-01

    The author has implanted 197 Fyodorov intraocular lenses. With careful selection of patients, good surgical judgment, and meticulous surgery, a degree of success can be obtained with this lens, which will equal that of conventional cataract surgery. The surgical technique of implantation will be described.

  11. Evaluate Bull Trout Movements in the Tucannon and Lower Snake Rivers, 2004 Annual Report.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Faler, Michael P.; Mendel, Glen W.; Fulton, Carl

    2005-11-01

    We sampled and released 313 bull trout (Salvelinus confluentus) from the Tucannon River in 2004. Passive Integrated Transponder (PIT) tags were inserted in 231 of these individuals, and we detected existing PIT tags in an additional 44 bull trout. Twenty-five of these were also surgically implanted with radio-tags, and we monitored the movements of these fish throughout the year. Ten bull trout that were radio-tagged in 2003 were known to survive and carry their tags through the spring of 2004. One of these fish outmigrated into the Snake River in the fall, and remained undetected until February, when it's tagmore » was located near the confluence of Alkali Flat Creek and the Snake River. The remaining 9 fish spent the winter between Tucannon River miles 2.1 (Powers Road) and 36.0 (Tucannon Fish Hatchery). Seven of these fish retained their tags through the summer, and migrated to known spawning habitat prior to September 2004. During June and July, radio-tagged bull trout again exhibited a general upstream movement into the upper reaches of the Tucannon subbasin. As in past years, we observed some downstream movements of radio-tagged bull trout in mid to late September and throughout October, suggesting post spawning outmigrations. By late November and early December, radio tagged bull trout were relatively stationary, and were distributed from river mile 42 at Camp Wooten downstream to river mile 17, near the Highway 12 bridge. As in previous years, we did not collect data associated with objectives 2, 3, or 4 of this study, because we were unable to monitor migratory movement of radio-tagged bull trout into the vicinity of the hydropower dams on the main stem Snake River. Transmission tests of submerged Lotek model NTC-6-2 nano-tags in Lower Granite Pool showed that audible detection and individual tag identification was possible at depths of 20, 30, and 40 ft. We were able to maintain tag detection and code separation at all depths from both a boat and 200 ft. above water surface in a helicopter. However, we lost detection capability from 40 ft. water depth when we passed 700 ft. above the water surface in a helicopter. Two years of high tag loss, particularly after spawning, has prevented us from documenting fall and winter movements with an adequate sample of radio tagged bull trout. The high transmitter loss after spawning may be a reflection of high natural mortality for large, older age fish that we have been radio tagging to accommodate the longer life transmitters. Therefore, we reduced the size of the radio tags that we implanted, and delayed most of our collection and tagging of bull trout until after spawning. These changes are a new approach to try to maximize the number of radio tagged bull trout available post spawning to adequately document fall and winter movements and any use of the Snake River by bull trout from the Tucannon River.« less

  12. [Augmentation with PMMA cement].

    PubMed

    Kühn, K-D; Höntzsch, D

    2015-09-01

    Cements based on polymethyl methacrylate (PMMA) can be used without any problem in a variety of clinical augmentations. Cement-related complications in surgical procedures involving PMMA cements, such as embolism, thermal necrosis, toxicity and hypersensitivity, are often due to other causes. Knowledge about the properties of the cement helps the user to safely employ PMMA cements in augmentations. High radio-opacity is required in vertebral body augmentations and this is provided in particular by zirconium dioxide. In vertebral body augmentations, a low benzoyl peroxide (BPO) content can considerably prolong the liquid dough phase. In augmentations with cement fillings in the region of a tumor, a high BPO content can specifically increase the peak temperature of the PMMA cement. In osteosynthetic augmentations with PMMA, necrosis is rare because heat development in the presence of metallic implants is low due to heat conduction via the implant. Larger cement fillings where there is no heat conduction via metal implants can exhibit substantially higher peak temperatures. The flow properties of PMMA cements are of particular importance for the user to allow optimum handling of PMMA cements. In patients with hypersensitivity to antibiotics, there is no need to avoid the use of PMMA as there are sufficient PMMA-based alternatives. The PMMA cements are local drug delivery systems and antibiotics, antiseptics, antimycotics and also cytostatics can be mixed with the cement. Attention must be paid to antagonistic and synergistic effects.

  13. Performance of implantable satellite transmitters in diving seabirds

    USGS Publications Warehouse

    Hatch, Shyla A.; Meyers, P.M.; Mulcahy, D.M.; Douglas, David C.

    2000-01-01

    We report on the first deployment of satellite transmitters in large alcids. In 1995 and 1996, we surgically implanted 51 transmitters in Common and Thick-billed murres (Uria aalge and U. lomvia) and Tufted Puffins (Fratercula cirrhata) at three colonies in Alaska. These devices furnished more than 2,900 locations over succeeding months (eight months maximum transmitter life), some 30-40% of which had calculated errors of <1,000 m. We considered other data to be reliable if locations were repetitive within a short period of time. As measures of data collection efficiency, we calculated location indices (number of locations per hour of transmission) of 0.44 during the breeding season and 0.35 overall. Those values compared favorably with satellite transmitters previously deployed on large mammals at similar latitudes. Transmitters did not last as long as expected because lithium batteries tended to self-discharge when kept at the high internal temperature of a bird. Most importantly, we encountered high mortality of instrumented birds, especially in the interval from 11-20 days after release. Our results suggest that radio transmission itself somehow impaired normal feeding behavior or otherwise compromised the birds' health. Those two problems (battery life and bird mortality) will need to be solved before implantable devices can be applied effectively to the same or similar species in the future. Received 24 August 1999, accepted 10 October 1999.

  14. Regenerative Surgical Treatment of Peri-implantitis

    ClinicalTrials.gov

    2016-08-31

    Failure of Dental Implant Due to Infection; Infection; Inflammation; Peri-implantitis; Bacterial Infections; Bleeding of Subgingival Space; Molecular Sequence Variation; Periodontal Diseases; Mouth Diseases

  15. Osseointegration of Plateau Root Form Implants: Unique Healing Pathway Leading to Haversian-Like Long-Term Morphology.

    PubMed

    Coelho, Paulo G; Suzuki, Marcelo; Marin, Charles; Granato, Rodrigo; Gil, Luis F; Tovar, Nick; Jimbo, Ryo; Neiva, Rodrigo; Bonfante, Estevam A

    2015-01-01

    Endosteal dental implants have been utilized as anchors for dental and orthopedic rehabilitations for decades with one of the highest treatment success rates in medicine. Such success is due to the phenomenon of osseointegration where after the implant surgical placement, bone healing results into an intimate contact between bone and implant surface. While osseointegration is an established phenomenon, the route which osseointegration occurs around endosteal implants is related to various implant design factors including surgical instrumentation and implant macro, micro, and nanometer scale geometry. In an implant system where void spaces (healing chambers) are present between the implant and bone immediately after placement, its inherent bone healing pathway results in unique opportunities to accelerate the osseointegration phenomenon at the short-term and its maintenance on the long-term through a haversian-like bone morphology and mechanical properties.

  16. Deep brain stimulation with a pre-existing cochlear implant: Surgical technique and outcome.

    PubMed

    Eddelman, Daniel; Wewel, Joshua; Wiet, R Mark; Metman, Leo V; Sani, Sepehr

    2017-01-01

    Patients with previously implanted cranial devices pose a special challenge in deep brain stimulation (DBS) surgery. We report the implantation of bilateral DBS leads in a patient with a cochlear implant. Technical nuances and long-term interdevice functionality are presented. A 70-year-old patient with advancing Parkinson's disease and a previously placed cochlear implant for sensorineural hearing loss was referred for placement of bilateral DBS in the subthalamic nucleus (STN). Prior to DBS, the patient underwent surgical removal of the subgaleal cochlear magnet, followed by stereotactic MRI, frame placement, stereotactic computed tomography (CT), and merging of imaging studies. This technique allowed for successful computational merging, MRI-guided targeting, and lead implantation with acceptable accuracy. Formal testing and programming of both the devices were successful without electrical interference. Successful DBS implantation with high resolution MRI-guided targeting is technically feasible in patients with previously implanted cochlear implants by following proper precautions.

  17. Different surgical strategies for implantation of continuous-flow VADs—Experience from Deutsches Herzzentrum Berlin

    PubMed Central

    Drews, Thorsten; Potapov, Evgenij; Weng, Yugo; Pasic, Miralem; Hetzer, Roland

    2014-01-01

    Objective This manuscript summarizes our surgical experience with the implantation of recent continuous-flow left ventricular assist devices (LVADs), with special emphasis on the HeartWare HVAD pump. Methods The HeartWare HVAD is, in our experience currently implanted in four different techniques: (I) “Classical” LVAD implantation with heart-lung machine and median sternotomy; (II) “Minimally-invasive” implantation without sternotomy and without heart-lung machine; (III) “Lateral implantation” to the descending aorta; (IV) Using two continuous-flow LVADs for implantable biventricular support. Results Five-hundred and four HeartWare HVADs have been implanted using the described techniques in our institution up to now. Conclusions The HeartWare HVAD is a versatile device. It has been found to be eminently suited to these four different modes of implantation. PMID:25452906

  18. Surgical Outcomes of Ahmed or Baerveldt Tube Shunt Implantation for medically Uncontrolled Traumatic Glaucoma.

    PubMed

    Yadgarov, Arkadiy; Liu, Dan; Crane, Elliot S; Khouri, Albert S

    2017-01-01

    To describe postoperative surgical success of either Ahmed or Baerveldt tube shunt implantation for eyes with medically uncontrolled traumatic glaucoma. A review was carried out to identify patients with traumatic glaucoma that required tube shunt implantation between 2009 and 2015 at Rutgers University in Newark, New Jersey, USA. Seventeen eyes from 17 patients met inclusion criteria, including at least 3-month postoperative follow-up. The main outcome measure was surgical success at 1-year follow-up after tube implantation. Mean preoperative intraocular pressure (IOP) was 34.1 ± 8.2 mm Hg on 3.1 ± 1.6 ocular hypotensive medications. Nine eyes (53%) sustained closed globe injury. Ten eyes (59%) received an Ahmed valve shunt and seven eyes (41%) received a Baerveldt tube shunt. Surgical success rate at 1 year postoperatively was 83%. Compared to preoperative, the mean postoperative IOP was significantly lower (16.1 ± 3.5 mm Hg, p < 0.001) on significantly fewer ocular hypertensive medications (1.3 ± 1.6, p = 0.001) at a mean follow-up of 10 months. Mean IOP reduction at last follow-up was 49%. There were three cases of surgical failures: One case of hypotony, one case of tube extrusion with subsequent explan-tation, and one case requiring second tube insertion for IOP control. Implantation of an Ahmed or Baerveldt tube shunt provided successful control of IOP in patients with medically uncontrollable traumatic glaucoma. Yadgarov A, Liu D, Crane ES, Khouri AS. Surgical Outcomes of Ahmed or Baerveldt Tube Shunt Implantation for medically Uncontrolled Traumatic Glaucoma. J Curr Glaucoma Pract 2017;11(1):16-21.

  19. Image calibration and registration in cone-beam computed tomogram for measuring the accuracy of computer-aided implant surgery

    NASA Astrophysics Data System (ADS)

    Lam, Walter Y. H.; Ngan, Henry Y. T.; Wat, Peter Y. P.; Luk, Henry W. K.; Goto, Tazuko K.; Pow, Edmond H. N.

    2015-02-01

    Medical radiography is the use of radiation to "see through" a human body without breaching its integrity (surface). With computed tomography (CT)/cone beam computed tomography (CBCT), three-dimensional (3D) imaging can be produced. These imagings not only facilitate disease diagnosis but also enable computer-aided surgical planning/navigation. In dentistry, the common method for transfer of the virtual surgical planning to the patient (reality) is the use of surgical stent either with a preloaded planning (static) like a channel or a real time surgical navigation (dynamic) after registration with fiducial markers (RF). This paper describes using the corner of a cube as a radiopaque fiducial marker on an acrylic (plastic) stent, this RF allows robust calibration and registration of Cartesian (x, y, z)- coordinates for linking up the patient (reality) and the imaging (virtuality) and hence the surgical planning can be transferred in either static or dynamic way. The accuracy of computer-aided implant surgery was measured with reference to coordinates. In our preliminary model surgery, a dental implant was planned virtually and placed with preloaded surgical guide. The deviation of the placed implant apex from the planning was x=+0.56mm [more right], y=- 0.05mm [deeper], z=-0.26mm [more lingual]) which was within clinically 2mm safety range. For comparison with the virtual planning, the physically placed implant was CT/CBCT scanned and errors may be introduced. The difference of the actual implant apex to the virtual apex was x=0.00mm, y=+0.21mm [shallower], z=-1.35mm [more lingual] and this should be brought in mind when interpret the results.

  20. A novel implantable device for the treatment of obstructive sleep apnea: clinical safety and feasibility.

    PubMed

    Pavelec, Vaclav; Rotenberg, Brian W; Maurer, Joachim T; Gillis, Edward; Verse, Thomas

    2016-01-01

    Many cases of obstructive sleep apnea (OSA) involve collapse of the tongue base and soft palate during sleep, causing occlusion of the upper airway and leading to oxygen desaturation. Existing therapies can be effective, but they are plagued by patient adherence issues and the invasiveness of surgical approaches. A new, minimally invasive implant for OSA has been developed, which is elastic and contracts a few weeks after deployment, stabilizing the surrounding soft tissue. The device has had good outcomes in preclinical testing; this report describes the preliminary feasibility and safety of its implementation in humans. A prospective, multicenter, single-arm feasibility study was conducted. Subjects were adults with moderate-to-severe OSA who had previously failed or refused conventional continuous positive airway pressure treatment. Intraoperative feasibility data, postoperative pain, and safety information were collected for a 30-day postoperative period. Forty subjects participated (37 men, three women; average age of 46.1 years); each received two tongue-base implants and two soft-palate implants. Surgical procedure time averaged 43 minutes. Postsurgical pain resolved readily in most cases; at 30 days post implantation, <20% of subjects reported pain, which averaged less than two out of ten. Adverse events were generally the mild and expected sequelae of a surgical procedure with general anesthesia and intraoral manipulation. The device was well tolerated. Implant extrusions were reported with soft-palate implants (n=12), while tongue-base implants required few revisions (n=2). Quantitative and qualitative sleep effectiveness outcomes (including full-night polysomnographic and quality-of-life measures) will be presented in a subsequent report. Implantation of the device was feasible. Although a relatively high rate of extrusions occurred in the now-discontinued palate implants, tongue-base implants were largely stable and well tolerated. The minimally invasive and maintenance-free implant may provide a new alternative to higher morbidity surgical procedures.

  1. Feasibility of purely endoscopic intramedullary fixation of mandibular condyle fractures.

    PubMed

    Frake, Paul C; Goodman, Joseph F; Joshi, Arjun S

    2015-01-01

    The investigators of this study hypothesized that fractures of the mandibular condyle can be repaired using short-segment intramedullary implants and purely endoscopic surgical technique, using a basic science, human cadaver model in an academic center. Endoscopic instrumentation was used through a transoral mucosal incision to place intramedullary implants of 2 cm in length into osteotomized mandibular condyles. The surgical maneuvers that required to insert these implants, including condyle positioning, reaming, implant insertion, and seating of the mandibular ramus, are described herein. Primary outcome was considered as successful completion of the procedure. Ten cadaveric mandibular condyles were successfully repaired with rigid intramedullary internal fixation without the use of external incisions. Both insertion of a peg-type implant and screwing a threaded implant into the condylar head were possible. The inferior portion of the implant remained exposed, and the ramus of the mandible was manipulated into position on the implant using retraction at the sigmoid notch. The results of this study suggest that purely endoscopic repair of fractures of the mandibular condyle is possible by using short-segment intramedullary titanium implants and a transoral endoscopic approach without the need for facial incisions or punctures. The biomechanical advantages of these intramedullary implants, including improved strength and resistance to mechanical failure compared with miniplates, have been recently established. The combination of improved implant design and purely endoscopic technique may allow for improved fixation and reduced surgical- and implant-related morbidity in the treatment of condylar fractures.

  2. Bone-anchored titanium implants for auricular rehabilitation: case report and review of literature.

    PubMed

    Gumieiro, Emne Hammoud; Dib, Luciano Lauria; Jahn, Ricardo Schmitutz; Santos Junior, João Ferreira dos; Nannmark, Ulf; Granström, Gösta; Abrahão, Márcio

    2009-01-01

    Osseointegrated implants have acquired an important role in the prosthetic rehabilitation of patients with craniofacial defects. The main indications are lack of local tissue for autogenous reconstruction, previous reconstruction failure and selection of this technique by the patient. This paper presents a clinical case and discusses indications and advantages of the osseointegrated implant technique for retention of auricular prostheses. Case report, Universidade Federal de São Paulo (UNIFESP). A female patient received three auricular implants after surgical resection of a hemangioma in her left ear. The time taken for osseointegration of the temporal bone was three months. After fabrication of the implant-retained auricular prosthesis, the patient was monitored for 12 months. The clinical parameters evaluated showed good postoperative healing, healthy peri-implant tissue, good hygiene and no loss of implants. Good hygiene combined with thin and immobile peri-implant soft tissues resulted in minimal complications. Craniofacial implant integration appears to be site-dependent; increasing age affects osseointegration in the temporal bone. The frequency of adverse skin reactions in peri-implant tissues is generally low. The surgical technique for rehabilitation using implant-retained auricular prostheses seems to be simple. It is associated with low rates of adverse skin reactions and long-term complications. Prostheses anchored by osseointegrated implants seem to provide better retention than do prostheses supported on spectacle frames, less risk of discoloration through the use of adhesives and better esthetic results than do prostheses anchored in the surgical cavity.

  3. Concomitant transcatheter aortic valve and left ventricular assist device implantation.

    PubMed

    Baum, Christina; Seiffert, Moritz; Treede, Hendrik; Reichenspurner, Hermann; Deuse, Tobias

    2013-01-01

    Relevant aortic regurgitation (AR) requires surgical repair at the time of left ventricular assist device (LVAD) implantation to reduce recirculation and ensure adequate forward flow. We report here on a patient with moderate AR in a noncalcified aortic valve and extensive calcification of the ascending aorta. The latter precluded aortic-crossclamping and, thus, surgical intervention on the aortic valve. Although there were no valvular or annular calcifications, a JenaValve transcatheter heart valve was successfully placed transapically with subsequent LVAD implantation in one operation. We believe concomitant transcatheter aortic valve implantation (TAVI) and LVAD implantation is a promising hybrid procedure, even in patients with pure AR.

  4. Experimental implant communication of high data rate video using an ultra wideband radio link.

    PubMed

    Chávez-Santiago, Raúl; Balasingham, Ilangko; Bergsland, Jacob; Zahid, Wasim; Takizawa, Kenichi; Miura, Ryu; Li, Huan-Bang

    2013-01-01

    Ultra wideband (UWB) is one of the radio technologies adopted by the IEEE 802.15.6™-2012 standard for on-body communication in body area networks (BANs). However, a number of simulation-based studies suggest the feasibility of using UWB for high data rate implant communication too. This paper presents an experimental verification of said predictions. We carried out radio transmissions of H.264/1280×720 pixels video at 80 Mbps through a UWB multiband orthogonal frequency division multiplexing (MB-OFDM) interface in a porcine chirurgical model. The results demonstrated successful transmission up to a maximum depth of 30 mm in the abdomen and 33 mm in the thorax within the 4.2-4.8 GHz frequency band.

  5. Treatment Approach for Infection of Healed Fractures After Internal Fixation.

    PubMed

    Lawrenz, Joshua M; Frangiamore, Salvatore J; Rane, Ajinkya A; Cantrell, William Alex; Vallier, Heather A

    2017-11-01

    To review the efficacy of a treatment approach for patients with infection and colonized implants after open reduction and internal fixation of fractures. Retrospective case series. Level one trauma center. Twenty patients were treated for wound infection with colonized implants after open reduction and internal fixation. Surgical debridement, removal of implants, and a short postoperative oral antibiotic course. The course of patients after surgical debridement and removal of implants, including culture results, antibiotic administration, and presence of recurrent clinical infection and radiographic union. Twenty patients had clinical presentations, including skin breakdown, serous drainage, purulent drainage and/or exposed implants, most commonly of the tibia (15 of 20). Mean time from index procedure to debridement with implant removal was 19.7 months. At the time of debridement and implant removal, 18 of 20 (90%) patients had a positive intraoperative culture (16 routine cultures and 2 broth cultures). The most common bacteria were Enterobacter cloacae (5/17) and methicillin-sensitive Staphylococcus aureus (4/17). All patients had soft tissue healing without signs of recurrent infection after mean follow up of 40 months after implant removal. Surgical debridement with implant removal plus a short oral antibiotic course is effective to resolve wound infection with a colonized implant in the setting of healed fracture after internal fixation. Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.

  6. Mandibular single-implant overdentures: a review with surgical and prosthodontic perspectives of a novel approach.

    PubMed

    Alsabeeha, Nabeel; Payne, Alan G T; De Silva, Rohana K; Swain, Michael V

    2009-04-01

    To review the literature on mandibular single-implant overdentures (opposing complete maxillary dentures), and present surgical and prosthodontic perspectives of a novel approach for this treatment option. An electronic search through the databases of Pubmed, Embase and Medline using the linked key words 'mandibular single implant overdentures' was performed. The search was limited to English language articles published up to August 2008. Hand searches through articles retrieved from the electronic search, peer-reviewed journals and recent conference proceedings were also conducted. A limited number of reports were identified on mandibular single-implant overdentures (opposing maxillary complete dentures). They comprised of case-series reports, short-term prospective trials and current randomized-controlled clinical trials. Different loading protocols with different implant systems have been used, but always with regular diameter implants. Specific anatomical and vascular dangers of the mandibular midline symphysis are identified including a novel surgical approach using a currently available short, wide diameter tapered implant. In addition, the prosthodontic rationale for using a larger attachment system (incorporating a platform switch) for mandibular single-implant overdentures is described. The review reveals that there is a lack of published randomized clinical trials using mandibular single-implant overdentures, opposing maxillary complete dentures. Without the evidence from randomized clinical trials, routine use of this novel approach cannot be recommended, compared with using regular diameter implants and matching attachment systems.

  7. [New options in reconstructive pelvic floor surgery and surgery in urogynecology].

    PubMed

    Martan, A

    2006-12-01

    The aim of this paper is to provide a brief update review of reconstructive pelvic floor surgery and surgery in urogynecology, including the application of surgical implants. Review article. Gynecological and Obstetric Clinic, 1 LF UK and VFN, Prague. Summarization, compilation and classification of recent findings, opinions and recommendations on new options in surgical procedures of reconstructive pelvic floor surgery and surgery in gynecology, with emphasis on the use of implants and their introduction into common clinical practice. From the beginning of the 1990s, the view of pelvic floor defects and urinary incontinence in women started to change significantly. The validity of De Lancey's classification of vaginal fixation into 3 basic levels was confirmed, with resulting modifications in surgical procedures. The etiology of pelvic floor defects comprises not only labor trauma or incorrectly performed previous operations (e.g. hysterectomy), but also hereditary influences and changes in the metabolism of the connective tissue. When comparing patients with or without descensus, there is a significant difference in the composition of collagen connective tissue; these findings, and the frequency of recurrence in up to 40% of patients within 3 years after the operations, resulted in the introduction of allogenous implants--meshes in the surgical treatment. These have been used for a long time in surgical treatment of abdominal wall defects, and for the above reasons the polypropylene meshes were introduced in pelvic floor defects surgery, while their safety has been proved in accordance with the principles of Evidence Based Medicine. In gynecology, these materials are already used in the laparoscopic approach to treat female stress incontinence. Pelvic floor defects occur either isolated, or combined (a defect of anterior, posterior or medial segment, or combination of all), while the patients may at the same time suffer from a stress type of urinary incontinence (SI). In surgical treatment of this type of urinary incontinence (TVT, TVT-O, TVT-S) allogenous implants--tapes--are frequently used. The results of studies suggest that one factor affecting the success of the operation using allogenous implants is the surgeon's erudition and experience in pelvic and vaginal surgery, while the long-term effect of the operation also depends on the surgical procedure involved, i.e. on the correct selection of operation methods and decision whether to use an implant or not. The effect of various operations using implants may differ as well, especially there is a difference between operations where the implant is placed freely under the bladder, and those where it is stabilized by fixing the arms of the implant under the lower arms of symphysis. Another factor to consider is the material of the implant used. Material currently recommended according to Evidence Based Medicine is: a lightweight, flexible polypropylene; and according to Amid's classification: type 1, i.e. macro-porous, monofilament material. The advantage of surgical treatment of pelvic floor defect using implants consists in a low percentage of recurrence of the descensus; there is, however, a certain risk of rejection (around 5%) and shrinking of tissues provoked by the implant.

  8. Ahmed glaucoma valve implant: surgical technique and complications.

    PubMed

    Riva, Ivano; Roberti, Gloria; Oddone, Francesco; Konstas, Anastasios Gp; Quaranta, Luciano

    2017-01-01

    Implantation of Ahmed glaucoma valve is an effective surgical technique to reduce intraocular pressure in patients affected with glaucoma. While in the past, the use of this device was reserved to glaucoma refractory to multiple filtration surgical procedures, up-to-date mounting experience has encouraged its use also as a primary surgery for selected cases. Implantation of Ahmed glaucoma valve can be challenging for the surgeon, especially in patients who already underwent previous multiple surgeries. Several tips have to be acquired by the surgeon, and a long learning curve is always needed. Although the valve mechanism embedded in the Ahmed glaucoma valve decreases the risk of postoperative hypotony-related complications, it does not avoid the need of a careful follow-up. Complications related to this type of surgery include early and late postoperative hypotony, excessive capsule fibrosis around the plate, erosion of the tube or plate edge, and very rarely infection. The aim of this review is to describe surgical technique for Ahmed glaucoma valve implantation and to report related complications.

  9. Ahmed glaucoma valve implant: surgical technique and complications

    PubMed Central

    Riva, Ivano; Roberti, Gloria; Oddone, Francesco; Konstas, Anastasios GP; Quaranta, Luciano

    2017-01-01

    Implantation of Ahmed glaucoma valve is an effective surgical technique to reduce intraocular pressure in patients affected with glaucoma. While in the past, the use of this device was reserved to glaucoma refractory to multiple filtration surgical procedures, up-to-date mounting experience has encouraged its use also as a primary surgery for selected cases. Implantation of Ahmed glaucoma valve can be challenging for the surgeon, especially in patients who already underwent previous multiple surgeries. Several tips have to be acquired by the surgeon, and a long learning curve is always needed. Although the valve mechanism embedded in the Ahmed glaucoma valve decreases the risk of postoperative hypotony-related complications, it does not avoid the need of a careful follow-up. Complications related to this type of surgery include early and late postoperative hypotony, excessive capsule fibrosis around the plate, erosion of the tube or plate edge, and very rarely infection. The aim of this review is to describe surgical technique for Ahmed glaucoma valve implantation and to report related complications. PMID:28255226

  10. Unusual anchor pins placement and protocol deviations during computer-based implant placement in a patient with severe mandibular bone atrophy. A case report.

    PubMed

    Pozzi, A; Tallarico, M; Barlattani, A

    2012-06-01

    The aim of the study was to describe an unusual method to stabilize the surgical template during the treatment of a severely resorbed edentulous mandible by means of computer-guided implant surgery. Pre-operative computer-based planning revealed the difficulty to stabilize the surgical template in a 67-year-old healthy woman. A deviation of the original NobelGuide™ protocol was performed to ensure the stability of the surgical template: four anchor pins were used to stabilize the surgical template, two in the buccal side of the anterior template and two unusual pins were placed in the lingual site. Four straight TiUnite® Nobel Biocare™ implants were then placed, according to a modified All-on-4™ concept procedure, to avoid graft procedures and to reduce the cumulative chair-side treatment time and costs. A temporary restoration was placed immediately after implant placement. Three months later a definitive, full acrylic restoration was delivered.

  11. Ensuring safety of implanted devices under MRI using reversed RF polarization.

    PubMed

    Overall, William R; Pauly, John M; Stang, Pascal P; Scott, Greig C

    2010-09-01

    Patients with long-wire medical implants are currently prevented from undergoing magnetic resonance imaging (MRI) scans due to the risk of radio frequency (RF) heating. We have developed a simple technique for determining the heating potential for these implants using reversed radio frequency (RF) polarization. This technique could be used on a patient-to-patient basis as a part of the standard prescan procedure to ensure that the subject's device does not pose a heating risk. By using reversed quadrature polarization, the MR scan can be sensitized exclusively to the potentially dangerous currents in the device. Here, we derive the physical principles governing the technique and explore the primary sources of inaccuracy. These principles are verified through finite-difference simulations and through phantom scans of implant leads. These studies demonstrate the potential of the technique for sensitively detecting potentially dangerous coupling conditions before they can do any harm. 2010 Wiley-Liss, Inc.

  12. The effects of local nitroglycerin on the surgical delay procedure in prefabricated flaps by vascular implant in rats.

    PubMed

    Sá, Jairo Zacchê de; Aguiar, José Lamartine de Andrade; Cruz, Adriana Ferreira; Schuler, Alexandre Ricardo Pereira; Lima, José Ricardo Alves de; Marques, Olga Martins

    2012-12-01

    To evaluate the effect of local nitroglycerin on the viable area of a prefabricated flap for vascular implant in rats, and to investigate the surgical delay procedure. A femoral pedicle was implanted under the skin of the abdominal wall in forty Wistar rats. The animals were divided into four groups of ten: group 1 - without surgical delay procedure and local nitroglycerin; group 2 - with surgical delay procedure, but without local nitroglycerin; group 3 - without surgical delay procedure, but with local nitroglycerin; and group 4 - with simultaneous surgical delay procedure and local nitroglycerin. The percentages of the viable areas, in relation to the total flap, were calculated using AutoCAD R 14. The mean percentage value of the viable area was 8.9% in the group 1. 49.4% in the group 2; 8.4% in the group 3 and 1.1% in the group 4. There was significant difference between groups 1 and 2 (p=0.005), 1 and 4 (p=0.024), 2 and 3 (p=0.003), 2 and 4 (p=0.001). These results support the hypothesis that the closure of the arterial venous channels is responsible for the phenomenon of surgical delay procedure. Local nitroglycerin did not cause an increase in the prefabricated viable flap area by vascular implantation and decreased the viable flap area that underwent delay procedures.

  13. Cochlear Implants.

    ERIC Educational Resources Information Center

    Clark, Catherine; Scott, Larry

    This brochure explains what a cochlear implant is, lists the types of individuals with deafness who may be helped by a cochlear implant, describes the process of evaluating people for cochlear implants, discusses the surgical process for implanting the aid, traces the path of sound through the cochlear implant to the brain, notes the costs of…

  14. Study of breast implant rupture: MRI versus surgical findings.

    PubMed

    Vestito, A; Mangieri, F F; Ancona, A; Minervini, C; Perchinunno, V; Rinaldi, S

    2012-09-01

    This study evaluated the role of breast magnetic resonance (MR) imaging in the selective study breast implant integrity. We retrospectively analysed the signs of breast implant rupture observed at breast MR examinations of 157 implants and determined the sensitivity and specificity of the technique in diagnosing implant rupture by comparing MR data with findings at surgical explantation. The linguine and the salad-oil signs were statistically the most significant signs for diagnosing intracapsular rupture; the presence of siliconomas/seromas outside the capsule and/or in the axillary lymph nodes calls for immediate explantation. In agreement with previous reports, we found a close correlation between imaging signs and findings at explantation. Breast MR imaging can be considered the gold standard in the study of breast implants.

  15. A residual granuloma in association with a dental implant.

    PubMed

    McCracken, Michael S; Chavali, Ramakiran V; Al-Naief, Nasser Said; Eleazer, Paul D

    2012-04-01

    At times, dental implants are placed into sites with a history of periapical pathology. Sometimes the infection is active, and other times the tooth may have been extracted years before implant placement. In either case, the possibility exists for long-term residual cysts or infections that can negatively impact the prognosis of the implant. In this case report, an implant is placed into a healed mandibular ridge several months after extraction of the tooth. A radiolucency was noted on routine radiographic examination 2 years later. Surgical inspection and histology revealed a periapical granuloma with acute and chronic inflammatory cells. After surgical curettage of the site, the patient healed without complication. Implants may develop apical pathology as a result of a preexisting long-term residual infection.

  16. Surgical Tooth Implants, Combat and Field.

    DTIC Science & Technology

    1977-11-01

    assisted by Mr. Larry G. McCoy, We are gratefully indebted to our dental consultants from The Ohio State University , College of Dentistry: Dr...SURGICAL TOOTH IMPLANTS , COMBAT AND FIELD by Craig R. Hassler and Larry G. McCoy BACKGROUND Research interest in dental restorations has continued...terman, R.B., and Marshall , R.P. , “ Dental Anchors of Non-Natural Design Implanted In Miniature Swine ” , J. Dent. Res., 52, 124 (1973). (11) Mills

  17. Cochlear implants in children implanted in Jordan: A parental overview.

    PubMed

    Alkhamra, Rana A

    2015-07-01

    Exploring the perspective of parents on the cochlear implant process in Jordan. Sixty parents of deaf children were surveyed on the information gathering process prior to cochlear implant surgery, and their implant outcome expectations post-surgery. Whether child or parent characteristics may impact parents' post-surgical expectations was explored. Although parents used a variety of information sources when considering a cochlear implant, the ear, nose and throat doctor comprised their major source of information (60%). Parents received a range of information prior to cochlear implant but agreed (93.3%) on the need for a multidisciplinary team approach. Post-surgically, parents' expected major developments in the areas of spoken language (97%), and auditory skills (100%). Receiving education in mainstream schools (92%) was expected too. Parents perceived the cochlear implant decision as the best decision they can make for their child (98.3%). A significant correlation was found between parents contentment with the cochlear implant decision and expecting developments in the area of reading and writing (r=0.7). Child's age at implantation and age at hearing loss diagnosis significantly affected parents' post-implant outcome expectations (p<0.05). Despite the general satisfaction from the information quantity and quality prior to cochlear implant, parents agree on the need for a comprehensive multidisciplinary team approach during the different stages of the cochlear implant process. Parents' education about cochlear implants prior to the surgery can affect their post-surgical outcome expectations. The parental perspective presented in this study can help professionals develop better understanding of parents' needs and expectations and henceforth improve their services and support during the different stages of the cochlear implant process. Copyright © 2015. Published by Elsevier Ireland Ltd.

  18. Split-mouth comparison of the accuracy of computer-generated and conventional surgical guides.

    PubMed

    Farley, Nathaniel E; Kennedy, Kelly; McGlumphy, Edwin A; Clelland, Nancy L

    2013-01-01

    Recent clinical studies have shown that implant placement is highly predictable with computer-generated surgical guides; however, the reliability of these guides has not been compared to that of conventional guides clinically. This study aimed to compare the accuracy of reproducing planned implant positions with computer-generated and conventional surgical guides using a split-mouth design. Ten patients received two implants each in symmetric locations. All implants were planned virtually using a software program and information from cone beam computed tomographic scans taken with scan appliances in place. Patients were randomly selected for computer-aided design/computer-assisted manufacture (CAD/CAM)-guided implant placement on their right or left side. Conventional guides were used on the contralateral side. Patients underwent operative cone beam computed tomography postoperatively. Planned and actual implant positions were compared using three-dimensional analyses capable of measuring volume overlap as well as differences in angles and coronal and apical positions. Results were compared using a mixed-model repeated-measures analysis of variance and were further analyzed using a Bartlett test for unequal variance (α = .05). Implants placed with CAD/CAM guides were closer to the planned positions in all eight categories examined. However, statistically significant differences were shown only for coronal horizontal distances. It was also shown that CAD/CAM guides had less variability than conventional guides, which was statistically significant for apical distance. Implants placed using CAD/CAM surgical guides provided greater accuracy in a lateral direction than conventional guides. In addition, CAD/CAM guides were more consistent in their deviation from the planned locations than conventional guides.

  19. Utility of Intraoperative Neuromonitoring during Minimally Invasive Fusion of the Sacroiliac Joint.

    PubMed

    Woods, Michael; Birkholz, Denise; MacBarb, Regina; Capobianco, Robyn; Woods, Adam

    2014-01-01

    Study Design. Retrospective case series. Objective. To document the clinical utility of intraoperative neuromonitoring during minimally invasive surgical sacroiliac joint fusion for patients diagnosed with sacroiliac joint dysfunction (as a direct result of sacroiliac joint disruptions or degenerative sacroiliitis) and determine stimulated electromyography thresholds reflective of favorable implant position. Summary of Background Data. Intraoperative neuromonitoring is a well-accepted adjunct to minimally invasive pedicle screw placement. The utility of intraoperative neuromonitoring during minimally invasive surgical sacroiliac joint fusion using a series of triangular, titanium porous plasma coated implants has not been evaluated. Methods. A medical chart review of consecutive patients treated with minimally invasive surgical sacroiliac joint fusion was undertaken at a single center. Baseline patient demographics and medical history, intraoperative electromyography thresholds, and perioperative adverse events were collected after obtaining IRB approval. Results. 111 implants were placed in 37 patients. Sensitivity of EMG was 80% and specificity was 97%. Intraoperative neuromonitoring potentially avoided neurologic sequelae as a result of improper positioning in 7% of implants. Conclusions. The results of this study suggest that intraoperative neuromonitoring may be a useful adjunct to minimally invasive surgical sacroiliac joint fusion in avoiding nerve injury during implant placement.

  20. Assessment of Barotrauma from Rapid Decompression of Depth-Acclimated Juvenile Chinook Salmon Bearing Radiotelemetry Transmitters

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brown, Richard S.; Carlson, Thomas J.; Welch, Abigail E.

    2009-11-01

    This study investigated the mortality of and injury to juvenile Chinook salmon Oncorhynchus tshawytscha exposed to simulated pressure changes associated with passage through a large Kaplan hydropower turbine. Mortality and injury varied depending on whether a fish was carrying a transmitter, the method of transmitter implantation, the depth of acclimation, and the size of the fish. Juvenile Chinook salmon implanted with radio transmitters were more likely than those without to die or sustain injuries during simulated turbine passage. Gastric transmitter implantation resulted in higher rates of injury and mortality than surgical implantation. Mortality and injury increased with increasing pressure ofmore » acclimation. Injuries were more common in subyearling fish than in yearling fish. Gas emboli in the gills and internal hemorrhaging were the major causes of mortality. Rupture of the swim bladder and emphysema in the fins were also common. This research makes clear that the exposure of juvenile Chinook salmon bearing radiotelemetry transmitters to simulated turbine pressures with a nadir of 8-19 kPa can result in barotrauma, leading to immediate or delayed mortality. The study also identified sublethal barotrauma injuries that may increase susceptibility to predation. These findings have significant implications for many studies that use telemetry devices to estimate the survival and behavior of juvenile salmon as they pass through large Kaplan turbines typical of those within the Columbia River hydropower system. Our results indicate that estimates of turbine passage survival for juvenile Chinook salmon obtained with radiotelemetry devices may be negatively biased.« less

  1. Polymer-based wireless implantable sensor and platform for systems biology study

    NASA Astrophysics Data System (ADS)

    Xue, Ning

    Wireless implantable MEMS (microelectromechanical systems) devices have been developed over the past decade based on the combination of bio-MEMS and Radio frequency (RF) MEMS technology. These devices require the components of wireless telemetric antenna and the corresponding circuit. In the meanwhile, biocompatible material needs to be involved in the devices design. To supply maximum power upon the implantable device at given power supply from the external coil circuit, this dissertation theoretically analyzed the mutual inductance under the positions of variety of vertical distances, lateral displacements and angular misalignments between two coils in certain surgical coils misalignment situations. A planar spiral coil has been developed as the receiver coil of the coupling system. To get maximum induced voltage over the receiver circuit, different geometries of the power coil, system operation frequencies were investigated. An intraocular pressure (IOP) sensor has been developed consisting of only biocompatible matierials-SU-8 and gold. Its size is sufficiently small to be implanted in the eye. The measurement results showed that it has relatively linear pressure response, high resolution and relatively long working stability in saline environment. Finally, a simple and low cost micro-wells bio-chip has been developed with sole polydimethylsiloxane (PDMS) to be used for single cell or small group cells isolation. By performing atomic force microscopy (AFM), contact angle and x-ray photoelectron spectroscopy (XPS) measurements on the PDMS surfaces under various surface treatment conditions, the physical and chemical surface natures were thoroughly analyzed as the basis of study of cells attachment and isolation to the surfaces.

  2. A Systematic Review of Different Implants and Approaches for Proximal Interphalangeal Joint Arthroplasty

    PubMed Central

    Yamamoto, Michiro; Malay, Sunitha; Fujihara, Yuki; Zhong, Lin; Chung, Kevin C.

    2016-01-01

    Background Outcomes after implant arthroplasty for primary degenerative and posttraumatic osteoarthritis (OA) of proximal interphalangeal (PIP) joint were different according to the implant design and surgical approach. The purpose of this systematic review was to evaluate outcomes of various types of implant arthroplasty for PIP joint OA with emphasis on different surgical approaches. Methods The authors searched all available literature in the PubMed and EMBASE databases for articles reporting on outcomes of implant arthroplasty for PIP joint OA. Data collection included active arc of motion (AOM), extension lag, and complications. We combined the data of various types of surface replacement arthroplasty into one group to compare with silicone arthroplasty. Results A total of 849 articles were screened, yielding 40 studies for final review. The mean postoperative AOM and the mean gain in AOM of silicone implant with volar approach were 58° and 17° respectively which was greater than surface replacement implant with dorsal approach as 51° and 8°, respectively. The mean postoperative extension lag of silicone implant with volar approach and surface replacement with dorsal approach was 5° and 14° respectively. The revision rate of silicone implant with volar approach and surface replacement with dorsal approach was 6% and 18% at the mean follow-up period of 41.2 and 51 months, respectively. Conclusions Silicone implant with volar approach showed the best AOM with less extension lag and fewer complications after surgery among all the implant designs and surgical approaches. PMID:28445369

  3. Clinical, surgical, and electrical factors impacting residual hearing in cochlear implant surgery.

    PubMed

    Eshraghi, Adrien A; Ahmed, Jamal; Krysiak, Eric; Ila, Kadri; Ashman, Peter; Telischi, Fred F; Angeli, Simon; Prentiss, Sandra; Martinez, Diane; Valendia, Sandra

    2017-04-01

    This study recommends using soft surgical principal and round window insertion to protect residual hearing with favorable anatomical exposure. Further studies are needed to evaluate the impact of the electrical stimulation on the organ of corti and hearing. The objective of this study is to analyze various factors that impact on preservation of residual hearing post-implantation. A retrospective study was performed to analyze loss of residual hearing in a cohort of 225 patients implanted in a large academic center. Sixty-four patients met the inclusion criteria. The impact of age at implantation, gender, etiology of hearing loss, cochleostomy vs round window insertion, partial vs full insertion, and effect of initial stimulation were analyzed using appropriate statistical analysis. The overall hearing preservation rate for all implanted patients was 64%. Loss of residual hearing was significantly more observed in cases of cochleostomy and/or non-soft surgical techniques. No correlation was observed with age at implantation, gender, side of implant, device manufacturer, and presence of pre-lingual deafness vs post-lingual, full or partial electrode insertion. In addition, there was a small but significant decrease in hearing between pre-stimulation and post-stimulation audiograms at 6000 Hz.

  4. 3D accuracy of implant positions in template-guided implant placement as a function of the remaining teeth and the surgical procedure: a retrospective study.

    PubMed

    Schnutenhaus, Sigmar; Edelmann, Cornelia; Rudolph, Heike; Dreyhaupt, Jens; Luthardt, Ralph G

    2018-01-22

    The aim of this study was to investigate differences between the virtually planned and clinically achieved implant positions in completely template-guided implantations as a function of the type of edentulous space, the residual natural dentition, and the surgical implementation. Fifty-six patient cases with a total of 122 implants were evaluated retrospectively. The implantations were completely template-based. The data of the planned implant positions were overlaid with the actual clinical implant positions, followed by measurements of the 3D deviations in terms of coronal (x c ) and apical distance, height (x h ), and angulation (ang) and statistical analysis. The mean x c was 1.2 mm (SD 0.7 mm); the mean x a was 1.8 mm (SD 0.9 mm), the mean x h was 0.8 mm (SD 0.7 mm); and the mean ang was 4.8° (SD 3.1). The type of edentulous space and the jaw (maxilla/mandible) had no significant effect on the results in terms of implant positions. The presence of an adjacent natural tooth at the time of implantation had a significant influence on x h (p = 0.04) and ang (p = 0.05). No significant differences were found regarding the surgical approach for any of the parameters examined. The results of our study are in the same range as those of other studies. Template-guided implantation offers a high degree of accuracy even in the presence of different configurations of the residual dentition or different surgical approaches. A clinical benefit is therefore present, especially from a prosthetic point of view. The clinically achievable accuracy can be described as sufficient for further prosthetic treatment, given the intrinsic and methodological tolerances, making prosthetic rehabilitation safe and predictable.

  5. Early Feasibility Testing and Engineering Development of the Transapical Approach for the HeartWare MVAD Ventricular Assist System

    PubMed Central

    Tamez, Daniel; LaRose, Jeffrey A.; Shambaugh, Charles; Chorpenning, Katherine; Soucy, Kevin G; Sobieski, Michael A; Sherwood, Leslie; Giridharan, Guruprasad A; Monreal, Gretel; Koenig, Steven C; Slaughter, Mark S

    2014-01-01

    Implantation of ventricular assist devices (VADs) for treatment of end-stage heart failure (HF) falls decidedly short of clinical demand, which exceeds 100,000 HF patients per year. VAD implantation often requires major surgical intervention with associated risk of adverse events and long recovery periods. To address these limitations, HeartWare, Inc. (Miami Lakes, FL) has developed a platform of miniature ventricular devices with progressively reduced surgical invasiveness and innovative patient peripherals. One surgical implant concept is a transapical version of the miniaturized left ventricular assist device (MVAD). The HeartWare MVAD Pump® is a small, continuous flow, full-support device that has a displacement volume of 22mL. A new cannula configuration has been developed for transapical implantation, where the outflow cannula is positioned across the aortic valve. The two primary objectives for this feasibility study were to evaluate anatomic fit and surgical approach and efficacy of the transapical MVAD configuration. Anatomic fit and surgical approach were demonstrated using human cadavers (n=4). Efficacy was demonstrated in acute (n =2) and chronic (n = 1) bovine model experiments and assessed by improvements in hemodynamics, biocompatibility, flow dynamics, and histopathology. Potential advantages of the MVAD Pump include flow support in the same direction as the native ventricle, elimination of cardiopulmonary bypass, and minimally-invasive implantation. PMID:24399057

  6. Surgical and Technical Modalities for Hearing Restoration in Ear Malformations.

    PubMed

    Dazert, Stefan; Thomas, Jan Peter; Volkenstein, Stefan

    2015-12-01

    Malformations of the external and middle ear often go along with an aesthetic and functional handicap. Independent of additional aesthetic procedures, a successful functional hearing restoration leads to a tremendous gain in quality of life for affected patients. The introduction of implantable hearing systems (bone conduction and middle ear devices) offers new therapeutic options in this field. We focus on functional rehabilitation of patients with malformations, either by surgical reconstruction or the use of different implantable hearing devices, depending on the disease itself and the severity of malformation as well as hearing impairment. Patients with an open ear canal and minor malformations are good candidates for surgical hearing restoration of middle ear structures with passive titanium or autologous implants. In cases with complete fibrous or bony atresia of the ear canal, the most promising functional outcome and gain in quality of life can be expected with an active middle ear implant or a bone conduction device combined with a surgical aesthetic rehabilitation in a single or multi-step procedure. Although the surgical procedure for bone conduction devices is straightforward and safe, more sophisticated operations for active middle ear implants (e.g., Vibrant Soundbridge, MED-EL, Innsbruck, Austria) provide an improved speech discrimination in noise and the ability of sound localization compared with bone conduction devices where the stimulation reaches both cochleae. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  7. An evidence-based concept of implant dentistry. Utilization of short and narrow platform implants.

    PubMed

    Ruiz, Jose-Luis

    2012-09-01

    As a profession, we must remember that tooth replacement is not a luxury; it is often a necessity for health reasons. Although bone augmentation and CBCT and expensive surgical guides are often indicated for complex cases, they are being overused. Simple or straightforward implant cases, when there is sufficient natural bone for narrow or shorter implant, can be predictable performed by well-trained GPs and other trained specialists. Complex cases requiring bone augmentation and other complexities as described herein, should be referred to a surgical specialist. Implant courses and curricula have to be based on the level of complexity of implant surgery that each clinician wishes to provide to his or her patients. Using a "logical approach" to implant dentistry keeps cases simple or straightforward, and more accessible to patients by the correct use of narrow and shorter implants.

  8. [Preliminary safety and stability assessment of orthodontic miniscrew implantation guided by surgical template based on cone-beam CT images].

    PubMed

    Qiu, L L; Li, S; Bai, Y X

    2016-06-01

    To develop surgical templates for orthodontic miniscrew implantation based on cone-beam CT(CBCT)three-dimensional(3D)images and to evaluate the safety and stability of implantation guided by the templates. DICOM data obtained in patients who had CBCT scans taken were processed using Mimics software, and 3D images of teeth and maxillary bone were acquired. Meanwhile, 3D images of miniscrews were acquired using Solidworks software and processed with Mimics software. Virtual position of miniscrews was determined based on 3D images of teeth, bone, and miniscrews. 3D virtual templates were designed according to the virtual implantation plans. STL files were output and the real templates were fabricated with stereolithographic appliance(SLA). Postoperative CBCT scans were used to evaluate the implantation safety and the stability of miniscrews were investigated. All the templates were positioned accurately and kept stable throughout the implantation process. No root damage was found. The deviations were(1.73±0.65)mm at the corona, and(1.28±0.82)mm at the apex, respectively. The stability of miniscrews was fairly well. Surgical templates for miniscrew implantation could be acquired based on 3D CBCT images and fabricated with SLA. Implantation guided by these templates was safe and stable.

  9. Clinical outcomes of using lasers for peri-implantitis surface detoxification: a systematic review and meta-analysis.

    PubMed

    Mailoa, James; Lin, Guo-Hao; Chan, Hsun-Liang; MacEachern, Mark; Wang, Hom-Lay

    2014-09-01

    The aim of this systematic review is to compare the clinical outcomes of lasers with other commonly applied detoxification methods for treating peri-implantitis. An electronic search of four databases and a hand search of peer-reviewed journals for relevant articles were conducted. Comparative human clinical trials and case series with ≥ 6 months of follow-up in ≥ 10 patients with peri-implantitis treated with lasers were included. Additionally, animal studies applying lasers for treating peri-implantitis were also included. The included studies had to report probing depth (PD) reduction after the therapy. Seven human prospective clinical trials and two animal studies were included. In four and three human studies, lasers were accompanied with surgical and non-surgical treatments, respectively. The meta-analyses showed an overall weighted mean difference of 0.00 mm (95% confidence interval = -0.18 to 0.19 mm) PD reduction between the laser and conventional treatment groups (P = 0.98) for non-surgical intervention. In animal studies, laser-treated rough-surface implants had a higher percentage of bone-to-implant contact than smooth-surface implants. In a short-term follow-up, lasers resulted in similar PD reduction when compared with conventional implant surface decontamination methods.

  10. USING INTERNAL RADIO TRANSMITTERS TO DETERMINE THE BEHAVIORAL RESPONSE OF BULLFROGS, RANA CATESBEIANA, TO SEASONAL POND DRYING IN THE WILLAMETTE VALLEY, OREGON

    EPA Science Inventory

    We implanted radio tags in adult bullfrogs from three ponds located in a Willamette Valley game reserve to determine their behavior and habitat use as the ponds dried during late summer. We used radio telemetry and a Global Position System (GPS) to locate and record the position ...

  11. Natrelle Silicone Breast Implant Follow-Up Study: Demographics, Lifestyle, and Surgical Characteristics of More Than 50,000 Augmentation Subjects

    PubMed Central

    Picha, George J.; Murphy, Diane K.

    2016-01-01

    Background: A large, multicenter, 10-year observational study is being conducted to compare the long-term safety and effectiveness of Natrelle silicone breast implants with saline implants or national norms. Study baseline data and surgical characteristics are reported here. Methods: Women seeking primary augmentation, revision-augmentation, primary reconstruction, or revision-reconstruction participated. Eligible subjects had completed surgery and received one implant or matching implants. Baseline demographics, health, lifestyle, and surgical characteristics were recorded. Data are presented here for subjects (≥22 years old) who underwent primary augmentation or revision-augmentation. Results: Of 50,979 subjects who underwent augmentation procedures, 35,756 received silicone implants and 15,223 received saline implants. Of these, 86.3 percent underwent primary augmentation, and 13.7 percent underwent revision-augmentation; nearly all subjects (99.3 percent) received bilateral implants. In the primary augmentation group, 67.6 percent of subjects received silicone implants versus 86.1 percent in the revision-augmentation group. Median age was lower in the primary augmentation group compared with the revision-augmentation group (33 versus 42 years old, respectively). Most subjects were white nonsmokers and had attended college. Hispanic subjects and subjects with a body mass index of 25 kg/m2 or greater were more likely to receive saline versus silicone implants. Across groups, the most common characteristics by procedure or implant type included inframammary incision site (54.6 percent), partial (58.2 percent) or complete (31.9 percent) submuscular placement, smooth surface implants (93.1 percent), and implant size of 300 to 399 cc. Incision size was larger for silicone versus saline implants. Conclusion: These data add to the body of knowledge on women undergoing augmentation procedures by providing an unprecedented look at a large number of subjects. PMID:26710009

  12. Surgical results of trabeculectomy and Ahmed valve implantation following a previous failed trabeculectomy in primary congenital glaucoma patients.

    PubMed

    Lee, Naeun; Ma, Kyoung Tak; Bae, Hyoung Won; Hong, Samin; Seong, Gong Je; Hong, Young Jae; Kim, Chan Yun

    2015-04-01

    To compare the surgical results of trabeculectomy and Ahmed glaucoma valve implantation after a previous failed trabeculectomy. A retrospective comparative case series review was performed on 31 eye surgeries in 20 patients with primary congenital glaucoma who underwent trabeculectomy or Ahmed glaucoma valve implantation after a previous failed trabeculectomy with mitomycin C. The preoperative mean intraocular pressure was 25.5 mmHg in the trabeculectomy group and 26.9 mmHg in the Ahmed glaucoma valve implantation group (p = 0.73). The 48-month postoperative mean intraocular pressure was 19.6 mmHg in the trabeculectomy group and 20.2 mmHg in the Ahmed glaucoma valve implantation group (p = 0.95). The 12-month trabeculectomy success rate was 69%, compared with 64% for Ahmed glaucoma valve implantation, and the 48-month success rates were 42% and 36% for trabeculectomy and valve implantation, respectively. The success rates following the entire follow-up period were not significantly different between the two groups (p > 0.05 by log rank test). Postoperative complications occurred in 25% of the trabeculectomy-operated eyes and 9% of the Ahmed-implanted eyes (p = 0.38). There was no significant difference in surgical outcome between the trabeculectomy and Ahmed glaucoma valve implantation groups, neither of which had favorable results. However, the trabeculectomy group demonstrated a higher prevalence of adverse complications such as post-operative endophthalmitis.

  13. Evidence-based medicine: augmentation mammaplasty.

    PubMed

    Lista, Frank; Ahmad, Jamil

    2013-12-01

    After studying this article, the participant should be able to: 1. Recognize the role of biofilm in breast implant surgery and possible ways to reduce the incidence of capsular contracture. 2. Describe the advantages and disadvantages of various surgical approaches including the incision placement and implant location. 3. List the advantages and disadvantages of implant characteristics including implant fill, shell surface characteristics, and implant shape. 4. Take steps to avoid the phenomena of double capsule and late seroma. This article was prepared to accompany practice-based assessment with ongoing surgical education for the Maintenance of Certification for the American Board of Plastic Surgery. It is structured to outline the care of the patient presenting for cosmetic breast augmentation.

  14. Peri-implant bony overgrowth as a cause of revision surgery in auditory osseointegrated implantation.

    PubMed

    Tompkins, Jared J; Petersen, Dana K; Sharbel, Daniel D; McKinnon, Brian J; MacDonald, C Bruce

    2016-07-01

    Implantation of auditory osseointegrated implants, also known as bone-anchored hearing systems (BAHS), represents a surgical option for select pediatric patients aged 5 years or older with hearing loss. Functional indications in this patient population include conductive or mixed hearing loss. Common complications of implantation include skin infections, chronic skin irritation, hypertrophic skin overgrowth, and loose abutments. In a case series of 15 pediatric patients, we discovered an unexpectedly high skin-related complication rate requiring surgical revision of 53%. During revision surgery, we discovered 5 patients who exhibited significant bony overgrowth at the abutment site, a complication infrequently noted in past literature. Published by Elsevier Ireland Ltd.

  15. “In vitro” Implantation Technique Based on 3D Printed Prosthetic Prototypes

    NASA Astrophysics Data System (ADS)

    Tarnita, D.; Boborelu, C.; Geonea, I.; Malciu, R.; Grigorie, L.; Tarnita, D. N.

    2018-06-01

    In this paper, Rapid Prototyping ZCorp 310 system, based on high-performance composite powder and on resin-high strength infiltration system and three-dimensional printing as a manufacturing method are used to obtain physical prototypes of orthopaedic implants and prototypes of complex functional prosthetic systems directly from the 3D CAD data. These prototypes are useful for in vitro experimental tests and measurements to optimize and obtain final physical prototypes. Using a new elbow prosthesis model prototype obtained by 3D printing, the surgical technique of implantation is established. Surgical implantation was performed on male corpse elbow joint.

  16. Production and characterization of monospecific adult worm infections of Strongylus vulgaris and Strongylus edentatus in ponies.

    PubMed

    McClure, J R; Chapman, M R; Klei, T R

    1994-02-01

    Since 1978, 20 surgical implantations of either Strongylus vulgaris or Strongylus edentatus have been performed in our laboratory for the purpose of obtaining single species cultures of these parasites. Following surgical implantation peak EPG values of 13-327 (S. vulgaris) and 363-1284 (S. edentatus) generally occurred during the first 3 weeks post-implantation. Duration of infections was as long as 5 years. Successful outcome of such surgeries appears to be related to the total number of parasites used (> or = 38) and the ratio of female to male worms implanted (1:1 or 2:1).

  17. Cochlear Implants

    MedlinePlus

    ... newsroom@entnet.org . A cochlear implant is an electronic device that restores partial hearing to individuals with ... An internal component that consists of a small electronic device that is surgically implanted under the skin ...

  18. Testing assumptions for unbiased estimation of survival of radiomarked harlequin ducks

    USGS Publications Warehouse

    Esler, Daniel N.; Mulcahy, Daniel M.; Jarvis, Robert L.

    2000-01-01

    Unbiased estimates of survival based on individuals outfitted with radiotransmitters require meeting the assumptions that radios do not affect survival, and animals for which the radio signal is lost have the same survival probability as those for which fate is known. In most survival studies, researchers have made these assumptions without testing their validity. We tested these assumptions by comparing interannual recapture rates (and, by inference, survival) between radioed and unradioed adult female harlequin ducks (Histrionicus histrionicus), and for radioed females, between right-censored birds (i.e., those for which the radio signal was lost during the telemetry monitoring period) and birds with known fates. We found that recapture rates of birds equipped with implanted radiotransmitters (21.6 ± 3.0%; x̄ ± SE) were similar to unradioed birds (21.7 ± 8.6%), suggesting that radios did not affect survival. Recapture rates also were similar between right-censored (20.6 ± 5.1%) and known-fate individuals (22.1 ± 3.8%), suggesting that missing birds were not subject to differential mortality. We also determined that capture and handling resulted in short-term loss of body mass for both radioed and unradioed females and that this effect was more pronounced for radioed birds (the difference between groups was 15.4 ± 7.1 g). However, no difference existed in body mass after recapture 1 year later. Our study suggests that implanted radios are an unbiased method for estimating survival of harlequin ducks and likely other species under similar circumstances.

  19. Soft Tissue Surgical Procedures for Optimizing Anterior Implant Esthetics

    PubMed Central

    Ioannou, Andreas L.; Kotsakis, Georgios A.; McHale, Michelle G.; Lareau, Donald E.; Hinrichs, James E.; Romanos, Georgios E.

    2015-01-01

    Implant dentistry has been established as a predictable treatment with excellent clinical success to replace missing or nonrestorable teeth. A successful esthetic implant reconstruction is predicated on two fundamental components: the reproduction of the natural tooth characteristics on the implant crown and the establishment of soft tissue housing that will simulate a healthy periodontium. In order for an implant to optimally rehabilitate esthetics, the peri-implant soft tissues must be preserved and/or augmented by means of periodontal surgical procedures. Clinicians who practice implant dentistry should strive to achieve an esthetically successful outcome beyond just osseointegration. Knowledge of a variety of available techniques and proper treatment planning enables the clinician to meet the ever-increasing esthetic demands as requested by patients. The purpose of this paper is to enhance the implant surgeon's rationale and techniques beyond that of simply placing a functional restoration in an edentulous site to a level whereby an implant-supported restoration is placed in reconstructed soft tissue, so the site is indiscernible from a natural tooth. PMID:26124837

  20. A new surgical template with a handpiece positioner for use during flapless placement of four dental implants to retain a mandibular overdenture.

    PubMed

    Elsyad, Moustafa Abdou

    2012-10-01

    This article describes the fabrication of a new and inexpensive surgical template from a radiographic template for flapless placement of dental implants to retain a mandibular overdenture. A radiographic template with radiopaque metal plate markers is constructed and used as a guide for achieving three-dimensional evaluation of bone using computed tomography (CT). The potential position and angulation of the implants are measured relative to the metal plates using the CT data. The radiographic template is converted into a surgical template by attaching rigid metal rods that guide the handpiece precisely during subsequent drilling procedures. © 2012 by the American College of Prosthodontists.

  1. Bacteriological evaluation for one-and two-piece implant design supporting mandibular overdenture

    PubMed Central

    Abdelwahed, Ahmed; Mahrous, Ahmed I.; Abadallah, Mohamed Farouk; Asfour, Hani; Aldawash, Hussien A.; Alagha, Ebaa I.

    2015-01-01

    Background: This study evaluated and compared the bacteriological effect of two-piece implants and one-piece implants in complete overdenture cases on supporting structures. Materials and Methods: Ten male completely edentulous patients were selected and randomly divided into two equal groups according to the implant design and surgical technique for this study; Group 1: Patients were rehabilitated with complete mandibular overdenture supported by two-piece implants one on each side of the lower arch following two-stage surgical technique and Group 2: Patients were rehabilitated with complete mandibular overdenture supported by one-piece implants one on each side. Evaluation was made at the time of insertion, 6, 12, and 18 months after overdenture insertion, by measuring bacteriological changes around implants abutments. Results: Complete overdenture supported by one-piece implants showed better effect on the bacteriological changes as compared to that supported by two-piece implants. Conclusion: Complete overdenture supported by one-piece implants one on each side of the lower arch showed better effect on the bacteriological changes than using the same prosthesis supported by two-piece implants. PMID:26903697

  2. Accuracy of different types of computer-aided design/computer-aided manufacturing surgical guides for dental implant placement

    PubMed Central

    Geng, Wei; Liu, Changying; Su, Yucheng; Li, Jun; Zhou, Yanmin

    2015-01-01

    Purpose: To evaluate the clinical outcomes of implants placed using different types of computer-aided design/computer-aided manufacturing (CAD/CAM) surgical guides, including partially guided and totally guided templates, and determine the accuracy of these guides Materials and methods: In total, 111 implants were placed in 24 patients using CAD/CAM surgical guides. After implant insertion, the positions and angulations of the placed implants relative to those of the planned ones were determined using special software that matched pre- and postoperative computed tomography (CT) images, and deviations were calculated and compared between the different guides and templates. Results: The mean angular deviations were 1.72 ± 1.67 and 2.71 ± 2.58, the mean deviations in position at the neck were 0.27 ± 0.24 and 0.69 ± 0.66 mm, the mean deviations in position at the apex were 0.37 ± 0.35 and 0.94 ± 0.75 mm, and the mean depth deviations were 0.32 ± 0.32 and 0.51 ± 0.48 mm with tooth- and mucosa-supported stereolithographic guides, respectively (P < .05 for all). The mean distance deviations when partially guided (29 implants) and totally guided templates (30 implants) were used were 0.54 ± 0.50 mm and 0.89 ± 0.78 mm, respectively, at the neck and 1.10 ± 0.85 mm and 0.81 ± 0.64 mm, respectively, at the apex, with corresponding mean angular deviations of 2.56 ± 2.23° and 2.90 ± 3.0° (P > .05 for all). Conclusions: Tooth-supported surgical guides may be more accurate than mucosa-supported guides, while both partially and totally guided templates can simplify surgery and aid in optimal implant placement. PMID:26309497

  3. The clinical outcomes of surgical management of anterior chamber migration of a dexamethasone implant (Ozurdex®).

    PubMed

    Kang, Hyunseung; Lee, Min Woo; Byeon, Suk Ho; Koh, Hyoung Jun; Lee, Sung Chul; Kim, Min

    2017-09-01

    Our purpose was to describe the clinical course, and individualized management approaches, of patients with migration of a dexamethasone implant into the anterior chamber. This was a retrospective review of four patients with seven episodes of anterior chamber migration of a dexamethasone implant. After 924 intravitreal dexamethasone injections, anterior migration of the implant occurred in four eyes of four patients (0.43%). All four eyes were pseudophakic: one eye had a posterior chamber intraocular lens in the capsular bag but in a post-laser posterior capsulotomy state, two eyes had a sulcus intraocular lens (IOL), and one eye had an iris-fixated retropupillary IOL. All eyes had a prior vitrectomy and no lens capsule. The time interval from injection to detection of the implant migration ranged from 2 to 6 weeks. Of the four eyes with corneal edema, only one eye required a corneal transplantation, although it was unclear whether the implant migration was the direct cause of the corneal decompensation because the patient had a history of bullous keratopathy resulting from an extended history of uveitis. All patients underwent surgical intervention: two patients with a repositioning procedure, and the other two patients with removal due to repeated episodes, although surgical removal was not always necessary to reverse the corneal complications. In our study, not all patients required surgical removal of the implants. Repositioning the implant back into the vitreous cavity may be considered as an option in cases involving the first episode with no significant corneal endothelial decompensation. Considering potential anterior segment complications and the loss of drug effectiveness together, an individualized approach is recommended to obtain the best treatment outcomes and to minimize the risk of corneal complications.

  4. Long-Term Mortality Effect of Early Pacemaker Implantation After Surgical Aortic Valve Replacement.

    PubMed

    Greason, Kevin L; Lahr, Brian D; Stulak, John M; Cha, Yong-Mei; Rea, Robert F; Schaff, Hartzell V; Dearani, Joseph A

    2017-10-01

    The need for pacemaker implantation is a well-described complication of aortic valve replacement. Not so well described is the effect such an event has on long-term outcome. This study reviewed a 21-year experience at the Mayo Clinic (Rochester, Minnesota) with aortic valve replacement to understand the influence of early postoperative pacemaker implantation on long-term mortality rates more clearly. This study retrospectively reviewed the records of 5,842 patients without previous pacemaker implantation who underwent surgical aortic valve replacement from January 1993 through June 2014. The median age of these patients was 73 years (range, 65 to 79 years), the median ejection fraction was 62% (range, 53% to 68%), 3,853 patients were male (66%), and coronary artery bypass graft operation was performed in 2,553 (44%) of the patients studied. Early pacemaker implantation occurred in 146 patients (2.5%) within 30 days of surgical aortic valve replacement. The median follow-up of patients was 11.1 years (range, 5.8 to 16.5 years), and all-cause mortality rates were 2.4% at 30 days, 6.4% at 1 year, 23.1% at 5 years, 48.3% at 10 years, and 67.9% at 15 years postoperatively. Early pacemaker implantation was associated with an increased risk of death after multivariable adjustment for baseline patients' characteristics (hazard ratio, 1.49; 95% confidence interval, 1.20, 1.84; p < 0.001). Early pacemaker implantation as a complication of surgical aortic valve replacement is associated with an increased risk of long-term death. Valve replacement-related pacemaker implantation rates should be important considerations with respect to new valve replacement paradigms, especially in younger and lower-risk patients. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  5. Implant decontamination during surgical peri-implantitis treatment: a randomized, double-blind, placebo-controlled trial.

    PubMed

    de Waal, Yvonne C M; Raghoebar, Gerry M; Huddleston Slater, James J R; Meijer, Henny J A; Winkel, Edwin G; van Winkelhoff, Arie Jan

    2013-02-01

    The objective of this randomized, double-blind, placebo-controlled trial was to study the effect of implant surface decontamination with chlorhexidine (CHX)/cetylpyridinium chloride (CPC) on microbiological and clinical parameters. Thirty patients (79 implants) with peri-implantitis were treated with resective surgical treatment consisting of apically re-positioned flap, bone re-contouring and surface debridement and decontamination. Patients were randomly allocated to decontamination with 0.12% CHX + 0.05% CPC (test-group) or a placebo-solution (without CHX/CPC, placebo-group). Microbiological parameters were recorded during surgery; clinical and radiographical parameters were recorded before (pre-) treatment (baseline), and at 3, 6 and 12 months after treatment. Nine implants in two patients in the placebo-group were lost due to severe persisting peri-implantitis. Both decontamination procedures resulted in significant reductions of bacterial load on the implant surface, but the test-group showed a significantly greater reduction than the placebo-group (log 4.21 ± 1.89 versus log 2.77 ± 2.12, p = 0.006). Multilevel analysis showed no differences between both groups in the effect of the intervention on bleeding, suppuration, probing pocket depth and radiographical bone loss over time. Implant surface decontamination with 0.12% CHX + 0.05% CPC in resective surgical treatment of peri-implantitis leads to a greater immediate suppression of anaerobic bacteria on the implant surface than a placebo-solution, but does not lead to superior clinical results. The long-term microbiological effect remains unknown. © 2012 John Wiley & Sons A/S.

  6. A Systematic Review of Different Implants and Approaches for Proximal Interphalangeal Joint Arthroplasty.

    PubMed

    Yamamoto, Michiro; Malay, Sunitha; Fujihara, Yuki; Zhong, Lin; Chung, Kevin C

    2017-05-01

    Outcomes after implant arthroplasty for primary degenerative and posttraumatic osteoarthritis of the proximal interphalangeal joint were different according to the implant design and surgical approach. The purpose of this systematic review was to evaluate outcomes of various types of implant arthroplasty for proximal interphalangeal joint osteoarthritis, with an emphasis on different surgical approaches. The authors searched all available literature in the PubMed and EMBASE databases for articles reporting on outcomes of implant arthroplasty for proximal interphalangeal joint osteoarthritis. Data collection included active arc of motion, extension lag, and complications. The authors combined the data of various types of surface replacement arthroplasty into one group for comparison with silicone arthroplasty. A total of 849 articles were screened, yielding 40 studies for final review. The mean postoperative arc of motion and the mean gain in arc of motion of silicone implant with the volar approach were 58 and 17 degrees, respectively, which was greater than surface replacement implant with the dorsal approach at 51 and 8 degrees, respectively. The mean postoperative extension lag of silicone implant with the volar approach and surface replacement with the dorsal approach was 5 and 14 degrees, respectively. The revision rate of silicone implant with the volar approach and surface replacement with the dorsal approach was 6 percent and 18 percent at a mean follow-up of 41.2 and 51 months, respectively. Silicone implant with the volar approach showed the best arc of motion, with less extension lag and fewer complications after surgery among all the implant designs and surgical approaches.

  7. Patients' perceptions of implant placement surgery, the post-surgical healing and the transitional implant prostheses: a qualitative study.

    PubMed

    Kashbour, Wafa A; Rousseau, Nikki; Thomason, J Mark; Ellis, Janice S

    2017-07-01

    This study aimed to explore patients' thoughts, feelings about, and experiences of, implant placement surgery (IPS), the post-surgical healing stage and the immediate post-surgical transitional implant prosthesis (TIP) (fixed and removable). A qualitative study design was chosen and 38 semi-structured telephone and face-to-face interviews were conducted with 34 patients at different stages of implant treatment. The interviews were transcribed verbatim; the data collection and coding process followed the principles of thematic analysis, which was facilitated through the use of NVivo10. Patients anticipated that surgery would be painful and unpleasant but were prepared to accept this temporary discomfort for the expected benefits of implant treatment. However, a key finding was that patients felt they had overestimated the trauma of surgery but underestimated the discomfort and difficulties of the healing phase. A number of difficulties were also identified with the TIP phase following implant surgery. Existing research has tended to focus on the longer term benefits of dental implant treatment. This qualitative study has investigated in-depth patients' perceptions of dental implant surgery, including their experiences related to sedation, and of transitional implant restoration. While patients felt their concerns were overestimated in relation to the implant surgery, they experienced greater morbidity than they expected in the healing phase. Recommendations are made for relatively small changes in care provision which might improve the overall patient experience. Partial dentate patients treated with a fixed transitional prosthesis experienced advantages more quickly than patients with an overdenture. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  8. A comparison of two implant techniques on patient-based outcome measures: a report of flapless vs. conventional flapped implant placement.

    PubMed

    Lindeboom, Jerome A; van Wijk, Arjen J

    2010-04-01

    Flapless implant surgery is considered to offer advantages over the traditional flap access approach. There may be minimized bleeding, decreased surgical times and minimal patient discomfort. Controlled studies comparing patient outcome variables to support these assumptions, however, are lacking. The objective of this clinical study was to compare patient outcome variables using flapless and flapped implant surgical techniques. From January 2008 to October 2008, 16 consecutive patients with edentulous maxillas were included in the study. Patients were randomly allocated to either implant placement with a flapless procedure (eight patients, mean age 54.6 + or - 2.9 years) or surgery with a conventional flap procedure (eight patients, mean age 58.7 + or - 7.2 years). All implants were placed using a Nobel guide CT-guided surgical template. Outcome measures were the Dutch version of the Impact of Event Scale-Revised (IES-R), dental anxiety using the s-DAI and oral health-related quality of life (OHIP-14). Ninety-six implants were successfully placed. All implants were placed as two-phase implants and the after-implant placement dentures were adapted. No differences could be shown between conditions on dental anxiety (s-DAI), emotional impact (IES-R), anxiety, procedure duration or technical difficulty, although the flapless group did score consistently higher. The flap procedure group reported less impact on quality of life and included more patients who reported feeling no pain at all during placement. Differences found in the patient outcome variables do suggest that patients in the flapless implant group had to endure more than patients in the flap group.

  9. 34 CFR 300.113 - Routine checking of hearing aids and external components of surgically implanted medical devices.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ..., DEPARTMENT OF EDUCATION ASSISTANCE TO STATES FOR THE EDUCATION OF CHILDREN WITH DISABILITIES State... 34 Education 2 2010-07-01 2010-07-01 false Routine checking of hearing aids and external components of surgically implanted medical devices. 300.113 Section 300.113 Education Regulations of the...

  10. Some considerations concerning cochlear implantation in IFACF-ORL

    PubMed Central

    Hainarosie, M; Zainea, V; Serban, S; Georgescu, MG; Hainarosie, R; Marinescu, A; Georgescu, G

    2014-01-01

    The article analyzes the patients who have received a cochlear implant at “Prof. Dr. Dorin Hociota” Institute of Phonoaudiology and Functional ENT Surgery, Bucharest, over a period of 13 years, from the beginning of this program in the year 2000. It presents the types of devices used, the particularities of the patients, the surgical techniques and the outcome, critically analyzing the complications encountered. The authors’ comments on the selection of patient protocol, surgical intraoperative challenges and cochlear implant technologies and capabilities are presented. PMID:25870683

  11. The development of a non-invasive behavioral model of thermal heat stress in laboratory mice (Mus musculus).

    PubMed

    Mufford, J T; Paetkau, M J; Flood, N J; Regev-Shoshani, G; Miller, C C; Church, J S

    2016-08-01

    Many behavioral and physiological studies of laboratory mice employ invasive methods such as radio telemetry to measure key aspects of behavior and physiology. Radio telemetry requires surgical implants, which may impact mouse health and behavior, and thus reduce the reliability of the data collected. We developed a method to measure key aspects of thermoregulatory behavior without compromising animal welfare. We examined the thermoregulatory response to heat stress in a custom-built arena that permitted the use of simultaneous and continuous infrared thermography (IRT) and video capture. This allowed us to measure changes in surface body temperature and determine total distance traveled using EthoVision XT animal tracking software. Locomotor activity and surface body temperature differed between heat-stressed mice and mice kept within their thermal comfort zone. The former had an increase in surface body temperature and a decline in locomotor activity, whereas the latter had a stable surface body temperature and showed greater activity levels. Surface body temperature and locomotor activity are conventionally quantified by measurements taken at regular intervals, which limit the use and accuracy of the data. We obtained data of high resolution (i.e., recorded continuously) and accuracy that allowed for the examination of key physiological measurements such as energy expenditure and peripheral vasomotor tone. This novel experimental method for studying thermoregulatory behavior in mice using non-invasive tools has advantages over radio-telemetry and represents an improvement in laboratory animal welfare. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. An innovative therapy for peri-implantitis based on radio frequency electric current: numerical simulation results and clinical evidence.

    PubMed

    Cosoli, G; Scalise, L; Tricarico, G; Tomasini, E P; Cerri, G

    2016-08-01

    Peri-implantitis is a severe inflammatory pathology that affects soit and hard tissues surrounding dental implants. Nowadays, only prevention is effective to contrast peri-implantitis, but, in recent years, there is the clinical evidence of the efficiency of a therapy based on the application of radio frequency electric current, reporting that 81% of the cases (66 implants, 46 patients) were successfully treated. The aim of this paper is to present the therapy mechanism, exploring the distribution of the electric currents in normal and pathologic tissues. A 3D numerical FEM model of tooth root with a dental implant screwed in the alveolar bone has been realized and the therapy has been simulated in COMSOL Multiphysics® environment. Results show that the electric current is focused in the inflamed zone around the implant, due to the fact that its conductivity is higher than the healthy tissue one. Moreover, by means of a movable return electrode, the electric current and field lines can be guided in the most inflamed area, limiting the interference on healthy tissues and improving the therapy in the area of interest. In conclusion, it can be stated that this innovative therapy would make a personalized therapy for peri-implantitis possible, also through impedance measurements, allowing the clinician to evaluate the tissue inflammation state.

  13. Failure of Synthetic Implants: Strategies and Management.

    PubMed

    Jang, Yong Ju; Kim, Shin Ae; Alharethy, Sami

    2018-06-01

    Dorsal augmentation with synthetic implants is the most commonly performed rhinoplasty procedure, especially in the East-Asian region. However, as in all other surgical procedures, complications are inevitable. Complications that need to be managed surgically include displacement, deviation, suboptimal aesthetic outcome, extrusion, inflammation, infection, and changes in skin quality. Most complications can be easily managed with revision surgery. After the removal of the synthetic implant from the nasal dorsum, different dorsal implant materials such as dermofat, alloderm, or fascia-wrapped diced cartilage, conchal cartilage with perichondrial attachment, and costal cartilage are preferred. An irreversible change in the skin/soft tissue envelope poses a challenge that usually requires reconstructive surgery with a local flap. Therefore, early detection and prompt management of the complication are essential for minimizing the severity of the deformity and the complexity of the surgical procedures. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  14. EX-PRESS Glaucoma Filtration Device: efficacy, safety, and predictability

    PubMed Central

    Chan, Jessica E; Netland, Peter A

    2015-01-01

    Trabeculectomy has been the traditional primary surgical therapy for open-angle glaucoma. While trabeculectomy is effective in lowering intraocular pressure, complications associated with the procedure have motivated the development of alternative techniques and devices, including the EX-PRESS Glaucoma Filtration Device. This review describes the efficacy, safety, complication rates, and potential advantages and disadvantages of the EX-PRESS Glaucoma Filtration Device. EX-PRESS implantation is technically simpler compared with that of trabeculectomy, with fewer surgical steps. Vision recovery has been more rapid after EX-PRESS implantation compared with trabeculectomy. Intraocular pressure variation is lower during the early postoperative period, indicating a more predictable procedure. While efficacy of the EX-PRESS implant has been comparable to trabeculectomy, postoperative complications appear less common after EX-PRESS implantation compared with trabeculectomy. The EX-PRESS Glaucoma Filtration Device appears to be safe and effective in the surgical management of open-angle glaucoma. PMID:26366105

  15. Do Prolonged Prophylactic Antibiotics Reduce the Incidence of Surgical-Site Infections in Immediate Prosthetic Breast Reconstruction?

    PubMed

    Wang, Frederick; Chin, Robin; Piper, Merisa; Esserman, Laura; Sbitany, Hani

    2016-12-01

    Approximately 50,000 women in the United States undergo mastectomy and immediate prosthetic breast reconstruction annually, and most receive postoperative prophylactic antibiotics. The effect of these antibiotics on the risk of surgical-site infections remains unclear. The authors searched the Medline, Embase, and Cochrane Library databases for studies that compared less than 24 hours and greater than 24 hours of antibiotics following immediate prosthetic breast reconstruction. Primary outcomes were surgical-site infections and implant loss. Conservative random effects models were used to obtain pooled relative risk estimates. The authors identified 927 studies, but only four cohort studies and one randomized controlled trial met their inclusion criteria. Unadjusted incidences of surgical-site infections were 14 percent with more than 24 hours of antibiotics, 19 percent with less than 24 hours of antibiotics, and 16 percent overall. Unadjusted incidences of implant loss were 8 percent with more than 24 hours of antibiotics, 10 percent with less than 24 hours of antibiotics, and 9 percent overall. The pooled relative risk of implant loss was 1.17 (95 percent CI, 0.39 to 3.6) with less than 24 hours of antibiotics, which was not statistically significant. Prolonged antibiotic use did not have a statistically significant effect on reducing surgical-site infections or implant loss. There was significant heterogeneity between studies, and prolonged antibiotics may have increased the risk of implant loss in the randomized controlled trial. Definitive evidence may only be obtained with data from more prospective randomized controlled trials.

  16. Surgical and Patient Factors Affecting Marginal Bone Levels Around Dental Implants: A Comprehensive Overview of Systematic Reviews.

    PubMed

    Ting, Miriam; Tenaglia, Matthew S; Jones, Gary H; Suzuki, Jon B

    2017-04-01

    The objective of this systematic review was to perform a comprehensive overview of systematic reviews and meta-analyses of surgical and patient factors affecting marginal bone loss around osseointegrated dental implants in humans. Electronic databases were searched for systematic reviews and meta-analyses published up to November 2015. Of the 41 articles selected, 11 evaluated implant factors, 10 evaluated patient factors, 19 evaluated surgical protocol-related factors, and one evaluated all three factors. The chosen studies were AMSTAR rated for quality. The following parameters have statistically significant effect on marginal bone loss: (1) marginal bone loss was significantly more in patients with periodontitis than in periodontally healthy patients; (2) significantly greater in generalized aggressive periodontitis patients compared with chronic periodontitis patients; (3) significantly less in alveolar socket preservation techniques; (4) significantly more in alveolar ridge augmentation sites; (5) significantly more in men than in women; (6) significantly more in smokers than in nonsmokers; and (7) smokers also have significantly more marginal bone loss in the maxilla than in the mandible. Knowledge of the surgical and patient factors that affect marginal bone loss can aid the clinician in making informed choices in selecting implant treatment options that will enhance the longevity and long-term success of their implant-supported cases.

  17. Matching layer for path loss reduction in ultra wideband implant communications.

    PubMed

    Chavez-Santiago, Raul; Khaleghi, Ali; Balasingham, Ilangko

    2014-01-01

    Real-time monitoring of various physiological signals is of utmost importance for the treatment of chronic conditions. Radio technology can enable real-time sensing and collection of physiological data to facilitate timely medication and early pre-hospital management of patients. This can be realized with the aid of implantable biomedical sensors with the capability to transmit wirelessly the collected information to an external unit for display and analysis. Currently, commercial wireless medical implantable sensors operate in frequencies below 1 GHz with narrowband signals. Recently, it has been demonstrated that ultra wideband (UWB) signals could be also used for the radio interface of these devices. However, establishing an implant communication link in the allocated UWB spectrum of 3.1-10.6 GHz is challenging. The attenuation of UWB signals propagating through biological tissues at these frequencies is high. Part of these path losses are caused by the impedance mismatch between the two propagation environments (i.e., air and biological tissues) that constitute an implant communication link. This mismatch results in inefficient power transmission of the radio waves. In this paper we propose the use of a layer of dielectric material that can be applied on the patient's skin. The permittivity value of this matching layer has to be chosen such that wave coupling is maximized. Through numerical simulations we determined the appropriate permittivity value of a matching layer for UWB implant communication links in the human thorax for 1-6 GHz. Path loss reduction of up to 10 dB can be obtained in this frequency band. These results can help improve the use of UWB signals for other in-body biomedical devices like the wireless capsule endoscope (WCE).

  18. Complex radial folds versus subtle signs of intracapsular rupture of breast implants: MR findings with surgical correlation.

    PubMed

    Soo, M S; Kornguth, P J; Walsh, R; Elenberger, C D; Georgiade, G S

    1996-06-01

    Detection of intracapsular rupture of silicone breast prostheses using MR imaging is often performed by identifying the "linguine sign" [1]. The linguine sign is easily differentiated from simple radial folds that are seen in intact implants. However, more subtle signs of intracapsular rupture, including undulating subcapsular lines and the "teardrop sign," are less often recognized [2-5] and may prove difficult for the less experienced radiologist to differentiate from complex radial folds of intact implants. In this essay, we illustrate the MR imaging findings of complex radial folds in intact implants and compare them with findings of incomplete shell collapse in ruptured implants in a surgically confirmed series of explanted silicone breast prostheses.

  19. Computed Tomographic Analysis of Ventral Atlantoaxial Optimal Safe Implantation Corridors in 27 Dogs.

    PubMed

    Leblond, Guillaume; Gaitero, Luis; Moens, Noel M M; Zur Linden, Alex; James, Fiona M K; Monteith, Gabrielle J; Runciman, John

    2017-11-01

    Objectives  Ventral atlantoaxial stabilization techniques are challenging surgical procedures in dogs. Available surgical guidelines are based upon subjective anatomical landmarks, and limited radiographic and computed tomographic data. The aims of this study were (1) to provide detailed anatomical descriptions of atlantoaxial optimal safe implantation corridors to generate objective recommendations for optimal implant placements and (2) to compare anatomical data obtained in non-affected Toy breed dogs, affected Toy breed dogs suffering from atlantoaxial instability and non-affected Beagle dogs. Methods  Anatomical data were collected from a prospectively recruited population of 27 dogs using a previously validated method of optimal safe implantation corridor analysis using computed tomographic images. Results  Optimal implant positions and three-dimensional numerical data were generated successfully in all cases. Anatomical landmarks could be used to generate objective definitions of optimal insertion points which were applicable across all three groups. Overall the geometrical distribution of all implant sites was similar in all three groups with a few exceptions. Clinical Significance  This study provides extensive anatomical data available to facilitate surgical planning of implant placement for atlantoaxial stabilization. Our data suggest that non-affected Toy breed dogs and non-affected Beagle dogs constitute reasonable research models to study atlantoaxial stabilization constructs. Schattauer GmbH Stuttgart.

  20. Findings from the experience with the punch technique for auditory osseointegrated implants: A retrospective single center comparative study.

    PubMed

    Bonilla, Alfonso; Magri, Carlos; Juan, Eulalia

    To compare the punch technique and linear incision with soft tissue reduction for the placement of auditory osseointegrated implants (AOI) and analyze results of osseointegration obtained with the punch technique as measured with the Implant Stability Quotient (ISQ). Case review of 34 patients who received auditory osseointegrated implants between January 2010 and July 2015 and were divided into two groups according to the surgical technique: 18 with the punch technique (PT) and 16 with the linear incision technique (LI). Minimum follow-up was four months (mean: 24 months; range 4-64 months). Included in the analysis were patient profiles and records of the demographic data, surgical indications, surgical technique, implant placement, surgical time, intraoperative complications, as well as postsurgical complications (Holgers classification) and implant stability quotients (ISQ). Use of larger abutments was significantly greater in the PT group (PT, 10mm; LI, 6mm, p<0.001). The PT technique resulted in a shorter procedure than the LI (PT, 20min; LI, 45min, p<0.001). Holgers classification scores identified significantly fewer skin complications one week after surgery for the PT group; however, only small differences were seen between the two groups at the one- and three-month control visits. As shown for our cohort, the punch technique for surgical placement of AOI is faster and presents fewer immediate postoperative complications when compared to the linear incision technique. The clinical application of the ISQ is a useful, easy method to demonstrate the status of osseointegration and, thus, the stability of the device. Copyright © 2017 Elsevier España, S.L.U. and Sociedad Española de Otorrinolaringología y Cirugía de Cabeza y Cuello. All rights reserved.

  1. Lamb Temporal Bone as a Surgical Training Model of Round Window Cochlear Implant Electrode Insertion.

    PubMed

    Mantokoudis, Georgios; Huth, Markus E; Weisstanner, Christian; Friedrich, Hergen M; Nauer, Claude; Candreia, Claudia; Caversaccio, Marco D; Senn, Pascal

    2016-01-01

    The preservation of residual hearing in cochlear implantation opens the door for optimal functional results. This atraumatic surgical technique requires training; however, the traditional human cadaveric temporal bones have become less available or unattainable in some institutions. This study investigates the suitability of an alternative model, using cadaveric lamb temporal bone, for surgical training of atraumatic round window electrode insertion. A total of 14 lamb temporal bones were dissected for cochlear implantation by four surgeons. After mastoidectomy, visualization, and drilling of the round window niche, an atraumatic round window insertion of a Medel Flex24 electrode was performed. Electrode insertion depth and position were verified by computed tomography scans. All cochleas were successfully implanted using the atraumatic round window approach; however, surgical access through the mastoid was substantially different when compared human anatomy. The mean number of intracochlear electrode contacts was 6.5 (range, 4-11) and the mean insertion depth 10.4 mm (range, 4-20 mm), which corresponds to a mean angular perimodiolar insertion depth of 229 degrees (range 67-540°). Full insertion of the electrode was not possible because of the smaller size of the lamb cochlea in comparison to that of the human. The lamb temporal bone model is well suited as a training model for atraumatic cochlear implantation at the level of the round window. The minimally pneumatized mastoid as well as the smaller cochlea can help prepare a surgeon for difficult cochlear implantations. Because of substantial differences to human anatomy, it is not an adequate training model for other surgical techniques such as mastoidectomy and posterior tympanotomy as well as full electrode insertion.

  2. A new method of radio frequency links by coplanar coils for implantable medical devices.

    PubMed

    Xue, L; Hao, H W; Li, L; Ma, B Z

    2005-01-01

    A new method based on coplanar coils for the design of radio frequency links has been developed, to realize the communication between the programming wand and the implantable medical devices with shielding container simply and reliably. With the analysis of electronic and magnetic field theory, the communication model has been established and simulated, and the circuit has been designed and tested. The experimental results are consistent with the simulation fairly well. The voltage transfer ratio of the typical circuit with present parameters can reach as high as 0.02, which can fulfill the requirements of communication.

  3. Factors influencing immediate post-release survival of spectacled eiders following surgical implantation of transmitters with percutaneous antennae

    USGS Publications Warehouse

    Sexson, Matthew G.; Mulcahy, Daniel M.; Spriggs, Maria; Myers, Gwen E.

    2014-01-01

    Surgically implanted transmitters are a common method for tracking animal movements. Immediately following surgical implantation, animals pass through a critical recovery phase when behaviors may deviate from normal and the likelihood of individual survival may be reduced. Therefore, data collected during this period may be censored to minimize bias introduced by surgery-related behaviors or mortality. However, immediate post-release mortalities negate a sampling effort and reduce the amount of data potentially collected after the censoring period. Wildlife biologists should employ methods to support an animal’s survival through this period, but factors contributing to immediate post-release survival have not been formally assessed. We evaluated factors that potentially influenced the immediate post-release survival of 56 spectacled eiders (Somateria fischeri) marked with coelomically implanted satellite transmitters with percutaneous antennae in northern Alaska in 2010 and 2011. We modeled survival through the first 14 days following release and assessed the relative importance and effect of 15 covariates hypothesized to influence survival during this immediate post-release period. Estimated daily survival rate increased over the duration of the immediate post-release period; the probability of mortality was greatest within the first 5 days following release. Our top-ranking model included the effect of 2 blood analytes, pH and hematocrit, measured prior to surgical implantation of a transmitter. We found a positive response to pH; eiders exhibiting acidemia (low pH) prior to surgery were less likely to survive the immediate post-release period. We found a curvilinear response to hematocrit; eiders exhibiting extremely low or high pre-surgery hematocrit were also less likely to survive the immediate post-release period. In the interest of maximizing the survival of marked birds following release, hematological data obtained prior to surgical implantation of telemetry equipment may be useful when screening for optimal surgical candidates or informing appropriate response to mitigate potentially deleterious disorders such as acidemia.

  4. Surgical Treatment of Implants Affected by Periimplantitis After 15 Years of Loading: A Case Report.

    PubMed

    Nícoli, Lélis Gustavo; Pigossi, Suzane Cristina; Marcantonio, Cláudio; Leal Zandim-Barcelos, Daniela; Marcantonio, Elcio

    2016-04-01

    The aim of this case report is to describe the surgical treatment of 2 implants affected by periimplantitis after 15 years of loading. The treatment included mechanical and chemical decontamination with topical application of tetracycline associated with a regenerative approach. Both defects were filled with particulate autogenous bone from tuber and covered with resorbable collagen membrane. The follow-up of 30 and 13 months of the implants 24 and 14, respectively, showed an absence of clinical signs of periimplant inflammation and near-complete bone regeneration. The therapy approach was effective in eliminating periimplant inflammation and promoting bone gain around the implants.

  5. Effects of abdominally implanted radiotransmitters with percutaneous antennas on migration, reproduction, and survival of Canada geese

    USGS Publications Warehouse

    Hupp, Jerry W.; Pearce, John M.; Mulcahy, Daniel M.; Miller, David A.

    2006-01-01

    Abdominally implanted radiotransmitters with percutaneous antennas are increasingly used to monitor movements, survival, and reproduction of waterbirds. However, there has been relatively little assessment of the effects of such radios on avian demographic parameters or migration. We implanted either a 26- or 35-g abdominal transmitter with percutaneous antenna in 198 adult female lesser Canada geese (Branta canadensis parvipes) in Anchorage, Alaska during 2000 and 2001. We compared migration chronology, reproductive effort, and survival of radiomarked females to 118 control females marked with leg bands. Arrival dates following spring migration were similar among females in different treatments in 2001. However, in 2002, wind direction during late migration was less favorable, and arrival of females with 35-g radiotransmitters lagged 1–2 days behind that of control females. Nest initiation dates, clutch size, and mean egg volume were similar for 152 nests of females that lacked radios and 62 nests of radiomarked females. Estimated nesting propensity for females with operable radiotransmitters was 61% and 72% in 2001 and 2002, respectively. Apparent annual survival (ϕ = 0.82, 95% confidence interval: 0.76 to 0.87) was similar among treatments in the first year after geese were marked. In the second and third years after marking, model-averaged estimates for survival of females with large radiotransmitters were 10% lower than estimates for control females. However, the effect of large radios on long-term survival was equivocal because of uncertainty surrounding treatment estimates. We conclude that abdominally implanted radiotransmitters with percutaneous antennas had small effects on migration chronology but no apparent effects on fecundity. Abdominal transmitters can provide unbiased estimates of anserine survival in the first year after deployment. Because of the potentially greater effects of larger transmitters on migration and long-term survival, we recommend that biologists minimize the size of implanted transmitters and deploy radios with caution if long-term survival of marked birds is a concern.

  6. Surgical Results of Trabeculectomy and Ahmed Valve Implantation Following a Previous Failed Trabeculectomy in Primary Congenital Glaucoma Patients

    PubMed Central

    Lee, Naeun; Ma, Kyoung Tak; Bae, Hyoung Won; Hong, Samin; Seong, Gong Je; Hong, Young Jae

    2015-01-01

    Purpose To compare the surgical results of trabeculectomy and Ahmed glaucoma valve implantation after a previous failed trabeculectomy. Methods A retrospective comparative case series review was performed on 31 eye surgeries in 20 patients with primary congenital glaucoma who underwent trabeculectomy or Ahmed glaucoma valve implantation after a previous failed trabeculectomy with mitomycin C. Results The preoperative mean intraocular pressure was 25.5 mmHg in the trabeculectomy group and 26.9 mmHg in the Ahmed glaucoma valve implantation group (p = 0.73). The 48-month postoperative mean intraocular pressure was 19.6 mmHg in the trabeculectomy group and 20.2 mmHg in the Ahmed glaucoma valve implantation group (p = 0.95). The 12-month trabeculectomy success rate was 69%, compared with 64% for Ahmed glaucoma valve implantation, and the 48-month success rates were 42% and 36% for trabeculectomy and valve implantation, respectively. The success rates following the entire follow-up period were not significantly different between the two groups (p > 0.05 by log rank test). Postoperative complications occurred in 25% of the trabeculectomy-operated eyes and 9% of the Ahmed-implanted eyes (p = 0.38). Conclusions There was no significant difference in surgical outcome between the trabeculectomy and Ahmed glaucoma valve implantation groups, neither of which had favorable results. However, the trabeculectomy group demonstrated a higher prevalence of adverse complications such as post-operative endophthalmitis. PMID:25829827

  7. A Craniomaxillofacial Surgical Assistance Workstation for Enhanced Single-Stage Reconstruction Using Patient-Specific Implants.

    PubMed

    Murphy, Ryan J; Liacouras, Peter C; Grant, Gerald T; Wolfe, Kevin C; Armand, Mehran; Gordon, Chad R

    2016-11-01

    Craniomaxillofacial reconstruction with patient-specific, customized craniofacial implants (CCIs) is ideal for skeletal defects involving areas of aesthetic concern-the non-weight-bearing facial skeleton, temporal skull, and/or frontal-forehead region. Results to date are superior to a variety of "off-the-shelf" materials, but require a protocol computed tomography scan and preexisting defect for computer-assisted design/computer-assisted manufacturing of the CCI. The authors developed a craniomaxillofacial surgical assistance workstation to address these challenges and intraoperatively guide CCI modification for an unknown defect size/shape. First, the surgeon designed an oversized CCI based on his/her surgical plan. Intraoperatively, the surgeon resected the bone and digitized the resection using a navigation pointer. Next, a projector displayed the limits of the craniofacial bone defect onto the prefabricated, oversized CCI for the size modification process; the surgeon followed the projected trace to modify the implant. A cadaveric study compared the standard technique (n = 1) to the experimental technique (n = 5) using surgical time and implant fit. The technology reduced the time and effort needed to resize the oversized CCI by an order of magnitude as compared with the standard manual resizing process. Implant fit was consistently better for the computer-assisted case compared with the control by at least 30%, requiring only 5.17 minutes in the computer-assisted cases compared with 35 minutes for the control. This approach demonstrated improvement in surgical time and accuracy of CCI-based craniomaxillofacial reconstruction compared with previously reported methods. The craniomaxillofacial surgical assistance workstation will provide craniofacial surgeons a computer-assisted technology for effective and efficient single-stage reconstruction when exact craniofacial bone defect sizes are unknown.

  8. Intracapsular implant rupture: MR findings of incomplete shell collapse.

    PubMed

    Soo, M S; Kornguth, P J; Walsh, R; Elenberger, C; Georgiade, G S; DeLong, D; Spritzer, C E

    1997-01-01

    The objective of this study was to determine the frequency and significance of the MR findings of incomplete shell collapse for detecting implant rupture in a series of surgically removed breast prostheses. MR images of 86 breast implants in 44 patients were studied retrospectively and correlated with surgical findings at explantation. MR findings included (a) complete shell collapse (linguine sign), 21 implants; (b) incomplete shell collapse (subcapsular line sign, teardrop sign, and keyhole sign), 33 implants; (c) radial folds, 31 implants; and (d) normal, 1 implant. The subcapsular line sign was seen in 26 implants, the teardrop sign was seen in 27 implants, and the keyhole sign was seen in 23 implants. At surgery, 48 implants were found to be ruptured and 38 were intact. The MR findings of ruptured implants showed signs of incomplete collapse in 52% (n = 25), linguine sign in 44% (n = 21), and radial folds in 4% (n = 2). The linguine sign perfectly predicted implant rupture, but sensitivity was low. Findings of incomplete shell collapse improved sensitivity and negative predictive values, and the subcapsular line sign produced a significant incremental increase in predictive ability. MRI signs of incomplete shell collapse were more common than the linguine sign in ruptured implants and are significant contributors to the high sensitivity and negative predictive values of MRI for evaluating implant integrity.

  9. Unified Approach to the Biomechanics of Dental Implantology

    NASA Technical Reports Server (NTRS)

    Grenoble, D. E.; Knoell, A. C.

    1973-01-01

    The human need for safe and effective dental implants is well-recognized. Although many implant designs have been tested and are in use today, a large number have resulted in clinical failure. These failures appear to be due to biomechanical effects, as well as biocompatibility and surgical factors. A unified approach is proposed using multidisciplinary systems technology, for the study of the biomechanical interactions between dental implants and host tissues. The approach progresses from biomechanical modeling and analysis, supported by experimental investigations, through implant design development, clinical verification, and education of the dental practitioner. The result of the biomechanical modeling, analysis, and experimental phases would be the development of scientific design criteria for implants. Implant designs meeting these criteria would be generated, fabricated, and tested in animals. After design acceptance, these implants would be tested in humans, using efficient and safe surgical and restorative procedures. Finally, educational media and instructional courses would be developed for training dental practitioners in the use of the resulting implants.

  10. 47 CFR 95.628 - MedRadio transmitters.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... human body, radiated emissions and EIRP measurements for transmissions by stations authorized under this section may be made in accordance with a Commission-approved human body simulator and test technique. A... from a medical implant or medical body-worn device on that channel. The MedRadio communications session...

  11. 47 CFR 95.628 - MedRadio transmitters.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... human body, radiated emissions and EIRP measurements for transmissions by stations authorized under this section may be made in accordance with a Commission-approved human body simulator and test technique. A... from a medical implant or medical body-worn device on that channel. The MedRadio communications session...

  12. 47 CFR 95.1217 - Labeling requirements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... SERVICES Medical Device Radiocommunication Service (MedRadio) § 95.1217 Labeling requirements. (a) MedRadio... operating in the 400.150-406.000 MHz band in the Meteorological Aids, Meteorological Satellite, and Earth... shall be identified with a serial number. The FCC ID number associated with a medical implant...

  13. CAD/CAM-produced surgical guides: Optimizing the treatment workflow.

    PubMed

    Neugebauer, J; Kistler, F; Kistler, S; Züdorf, G; Freyer, D; Ritter, L; Dreiseidler, T; Kusch, J; Zöller, J E

    2011-01-01

    The increased availability of devices for 3D radiological diagnosis allows the more frequent use of CAD/CAM-produced surgical guides for implant placement. The conventional workflow requires a complex logistic chain which is time-consuming and costly. In a pilot study, the workflow of directly milled surgical guides was evaluated. These surgical guides were designed based on the fusion of an optical impression and the radiological data. The clinical use showed that the surgical guides could be accurately placed on the residual dentition without tipping movements. The conventional surgical guides were used as a control for the manual check of the deviation of the implant axis. The direct transfer of the digital planning data allows the fabrication of surgical guides in an external center without the need of physical transport, which reduces the logistic effort and expense of the central fabrication of surgical guides.

  14. [Studies on the immunologic behavior of standardized virus-induced rat tumor after cryosurgical and surgical treatment].

    PubMed

    Jaeschock, R R

    1976-01-01

    The authors report on the behavior of a virus-induced tumor in the rat after cryosurgical and surgical treatment and re-implantation of different tumor suspensions. No specific "immune-cryothermic response" could be demonstrated. The principle of the lysis of the re-implantate lies in devitalizing the primary tumor.

  15. 34 CFR 300.113 - Routine checking of hearing aids and external components of surgically implanted medical devices.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ..., DEPARTMENT OF EDUCATION ASSISTANCE TO STATES FOR THE EDUCATION OF CHILDREN WITH DISABILITIES State... 34 Education 2 2011-07-01 2010-07-01 true Routine checking of hearing aids and external components of surgically implanted medical devices. 300.113 Section 300.113 Education Regulations of the Offices...

  16. 34 CFR 300.113 - Routine checking of hearing aids and external components of surgically implanted medical devices.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 34 Education 2 2012-07-01 2012-07-01 false Routine checking of hearing aids and external... Eligibility Other Fape Requirements § 300.113 Routine checking of hearing aids and external components of surgically implanted medical devices. (a) Hearing aids. Each public agency must ensure that hearing aids worn...

  17. 34 CFR 300.113 - Routine checking of hearing aids and external components of surgically implanted medical devices.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 34 Education 2 2014-07-01 2013-07-01 true Routine checking of hearing aids and external components... Eligibility Other Fape Requirements § 300.113 Routine checking of hearing aids and external components of surgically implanted medical devices. (a) Hearing aids. Each public agency must ensure that hearing aids worn...

  18. 34 CFR 300.113 - Routine checking of hearing aids and external components of surgically implanted medical devices.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 34 Education 2 2013-07-01 2013-07-01 false Routine checking of hearing aids and external... Eligibility Other Fape Requirements § 300.113 Routine checking of hearing aids and external components of surgically implanted medical devices. (a) Hearing aids. Each public agency must ensure that hearing aids worn...

  19. Treatment of peri-implantitis: clinical outcome of chloramine as an adjunctive to non-surgical therapy, a randomized clinical trial.

    PubMed

    Roos-Jansåker, Ann-Marie; Almhöjd, Ulrica S; Jansson, Henrik

    2017-01-01

    To evaluate the adjunctive clinical effects of a chloramine to non-surgical treatment of peri-implantitis. Eighteen individuals diagnosed with peri-implantitis (clinical signs of inflammation and progressive bone loss) on at least two implants were included. Clinical variables; plaque accumulation (Pl), probing depth (PD), clinical attachment level (CAL) and bleeding on probing (BoP), were recorded at baseline and at 3-month follow-up. Primary clinical efficacy variable was the change in the number of sites with BoP. The implants were randomized into two different treatment groups: test and control. Both implants received supra- and submucosal debridement by ultrasonic instrumentation supplemented with hand instruments. The implants assigned to the test group first received local applications of a chloramine gel (Perisolv ™ ; RLS Global AB, Gothenburg, Sweden) followed by mechanical instrumentation. The oral hygiene was checked at 6 weeks. After 3 months, implants of both groups showed statistically significant reduction (P < 0.001) in the number of BoP-positive sites compared with baseline. The reduction of BoP-positive sites in the test group changed from 0.97 (SD ± 0.12) to 0.38 (SD ± 0.46), and in the control group from 0.97 (SD ± 0.12) to 0.31 (SD ± 0.42). Between-group comparisons revealed no statistically significant differences at baseline and after 3 months, for BoP or any of the other variables. In the present randomized clinical trial of peri-implantitis therapy; non-surgical mechanical debridement with adjunctive use of a chloramine is equally effective in the reduction of mucosal inflammation as conventional non-surgical mechanical debridement up to 3 months. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  20. Implant Bed Preparation with an Erbium, Chromium Doped Yttrium Scandium Gallium Garnet (Er,Cr: YSGG) Laser Using Stereolithographic Surgical Guide

    PubMed Central

    Seymen, Gülin; Turgut, Zeynep; Berk, Gizem; Bodur, Ayşen

    2013-01-01

    Background: Implant bed preparation with laser is taken into consideration owing to the increased interest in use of lasers in hard tissue surgery. The purpose of this study is to determine the deviations in the position and inclination between the planned and prepared implant beds with Erbium, Chromium doped Yttrium Scandium Gallium Garnet (Er,Cr:YSGG) laser using stereolithographic (SLA) surgical guides. Methods: After 3-dimensional (3D) imaging of six sheep lower jaws, computed tomography (CT) images were transformed into 3D models. Locations of implant beds were determined on these models. Two implant beds in each half jaw were prepared with an Er,Cr:YSGG laser system and a conventional drilling method using a total of 12 SLA surgical guides. A new CT was taken to analyze the deviation values between planned and prepared implant beds. Finally, a software program was used to superimpose the images on 3D models, then the laser and conventional drilling groups were compared. Results: Differences of mean angular deviations between the planned and prepared implant beds were 5.17±4.91° in the laser group and 2.02±1.94° in the conventional drilling group.The mean coronal deviation values were found to be 0.48±0.25 mm and 0.23±0.14 mm in the laser group and conventional drilling group, respectively. While the mean deviation at the apex between the planned and prepared implant beds were 0.70±0.26 mm and 0.26±0.08 ,the mean vertical deviations were 0.06±0.15 mm and 0.02±0.05 mm for the laser group and the conventional drilling group, respectively. Conclusion: It is possible to prepare an implant bed properly with the aid of Er,Cr:YSGGlaser by using SLA surgical guide. PMID:25606303

  1. Transcatheter aortic valve implantation for failing surgical aortic bioprosthetic valve: from concept to clinical application and evaluation (part 2).

    PubMed

    Piazza, Nicolo; Bleiziffer, Sabine; Brockmann, Gernot; Hendrick, Ruge; Deutsch, Marcus-André; Opitz, Anke; Mazzitelli, Domenico; Tassani-Prell, Peter; Schreiber, Christian; Lange, Rüdiger

    2011-07-01

    This study sought to review the acute procedural outcomes of patients who underwent transcatheter aortic valve (TAV)-in-surgical aortic valve (SAV) implantation at the German Heart Center, Munich, and to summarize the existing literature on TAV-in-SAV implantation (n = 47). There are several case reports and small case series describing transcatheter aortic valve implantation for a failing surgical aortic valve bioprosthesis (TAV-in-SAV implantation). From January 2007 to March 2011, 20 out of 556 patients underwent a TAV-in-SAV implantation at the German Heart Center Munich. Baseline characteristics and clinical outcome data were prospectively entered into a dedicated database. The mean patient age was 75 ± 13 years, and the mean logistic European System for Cardiac Operative Risk Evaluation and Society of Thoracic Surgeons' Risk Model scores were 27 ± 13% and 7 ± 4%, respectively. Of the 20 patients, 14 had stented and 6 had stentless surgical bioprostheses. Most cases (12 of 20) were performed via the transapical route using a 23-mm Edwards Sapien prosthesis (Edwards Lifesciences, Irvine, California). Successful implantation of a TAV in a SAV with the patient leaving the catheterization laboratory alive was achieved in 18 of 20 patients. The mean transaortic valve gradient was 20.0 ± 7.5 mm Hg. None-to-trivial, mild, and mild-to-moderate paravalvular aortic regurgitation was observed in 10, 6, and 2 patients, respectively. We experienced 1 intraprocedural death following pre-implant balloon aortic valvuloplasty ("stone heart") and 2 further in-hospital deaths due to myocardial infarction. TAV-in-SAV implantation is a safe and feasible treatment for high-risk patients with failing aortic bioprosthetic valves and should be considered as part of the armamentarium in the treatment of aortic bioprosthetic valve failure. Copyright © 2011 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  2. Association between hospital procedure volume and early complications after pacemaker implantation: results from a large, unselected, contemporary cohort of the German nationwide obligatory external quality assurance programme.

    PubMed

    Nowak, Bernd; Tasche, Karl; Barnewold, Linda; Heller, Günther; Schmidt, Boris; Bordignon, Stefano; Chun, K R Julian; Fürnkranz, Alexander; Mehta, Rajendra H

    2015-05-01

    Several studies demonstrated an inverse relationship between cardioverter-defibrillator implantation volume and complication rates, suggesting better outcomes for higher volume centres. However, the association of institutional procedural volume with patient outcomes for permanent pacemaker (PPM) implantation remains less known, especially in decentralized implantation systems. We performed retrospective examination of data on patients undergoing PPM from the German obligatory quality assurance programme (2007-12) to evaluate the relationship of hospital PPM volume (categorized into quintiles of their mean annual volume) with risk-adjusted in-hospital surgical complications (composite of pneumothorax, haemothorax, pericardial effusion, or pocket haematoma, all requiring intervention, or device infection) and pacemaker lead dislocation. Overall 430 416 PPM implantations were documented in 1226 hospitals. Systems included dual (72.8%) and single (25.8%) chamber PPM and cardiac resynchronization therapy (CRT) devices (1.1%). Complications included surgical (0.92%), and ventricular (0.99%), and atrial (1.22%) lead dislocation. Despite an increase in relatively complex procedures (dual chamber, CRT), there was a significant decrease in the procedural and fluoroscopy times and complications from lowest to highest implantation volume quintiles (P for trend <0.0001). The greatest difference was observed between the lowest (1-50 implantations/year-reference group) and the second-lowest (51-90 implantations/year) quintile: surgical complications [odds ratio (OR) 0.69; confidence interval (CI) 0.60-0.78], atrial lead dislocations (OR 0.69; CI 0.59-0.80), and ventricular lead dislocations (OR 0.73; CI 0.63-0.84). Hospital annual PPM volume was directly related to indication-based implantation of relatively more complex PPM and yet inversely with procedural times and rates of early surgical complications and lead dislocations. Thus, our data suggest better performance and lower complications with increasing procedural volume. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.

  3. Core temperature rhythms in normal and tumor-bearing mice.

    PubMed

    Griffith, D J; Busot, J C; Lee, W E; Djeu, D J

    1993-01-01

    The core temperature temporal behavior of DBA/2 mice (11 normal and 13 with an ascites tumor) was studied using surgically implanted radio telemetry transmitters. Normal mice continuously displayed a stable 24 hour temperature rhythm. Tumor-bearers displayed a progressive deterioration of the temperature rhythm following inoculation with tumor cells. While such disruptions have been noted by others, details on the dynamics of the changes have been mostly qualitative, often due to time-averaging or steady-state analysis of the data. The present study attempts to quantify the dynamics of the disruption of temperature rhythm (when present) by continuously monitoring temperatures over periods up to a month. Analysis indicated that temperature regulation in tumor-bearers was adversely affected during the active period only. Furthermore, it appears that the malignancy may be influencing temperature regulation via pathways not directly attributable to the energy needs of the growing tumor.

  4. Evolution of general surgical problems in patients with left ventricular assist devices.

    PubMed

    McKellar, Stephen H; Morris, David S; Mauermann, William J; Park, Soon J; Zietlow, Scott P

    2012-11-01

    Left ventricular assist devices (LVADs) are increasingly used to treat patients with end-stage heart failure. These patients may develop acute noncardiac surgical problems around the time of LVAD implantation or, as survival continues to improve, chronic surgical problems as ambulatory patients remote from the LVAD implant. Previous reports of noncardiac surgical problems in LVAD patients included patients with older, first-generation devices and do not address newer, second-generation devices. We describe the frequency and management of noncardiac surgical problems encountered during LVAD support with these newer-generation devices to assist noncardiac surgeons involved in the care of patients with LVADs. We retrospectively reviewed the medical records of consecutive patients receiving LVADs at our institution. We collected data for any consultation by noncardiac surgeons within the scope of general surgery during LVAD support and subsequent treatment. Ninety-nine patients received implantable LVADs between 2003 and 2009 (first-generation, n = 19; second-generation, n = 80). Excluding intestinal hemorrhage, general surgical opinions were rendered for 34 patients with 49 problems, mostly in the acute recovery phase after LVAD implantation. Of those, 27 patients underwent 28 operations. Respiratory failure and intra-abdominal pathologies were the most common problems addressed, and LVAD rarely precluded operation. Patients with second-generation LVADs were more likely to survive hospitalization (P = .04) and develop chronic, rather than emergent, surgical problems. Patients with LVADs frequently require consultation from noncardiac surgeons within the scope of general surgeons and often require operation. Patients with second-generation LVADs are more likely to become outpatients and develop more elective surgical problems. Noncardiac surgeons will be increasingly involved in caring for patients with LVADs and should anticipate the problems unique to this patient population. Copyright © 2012 Mosby, Inc. All rights reserved.

  5. High resolution micro-CT scanning as an innovative tool for evaluation of the surgical positioning of cochlear implant electrodes.

    PubMed

    Postnov, A; Zarowski, A; De Clerck, N; Vanpoucke, F; Offeciers, F E; Van Dyck, D; Peeters, S

    2006-05-01

    X-ray microtomography (micro-CT) is a new technique allowing for visualization of the internal structure of opaque specimens with a quasi-histological quality. Among multiple potential applications, the use of this technique in otology is very promising. Micro-CT appears to be ideally suited for in vitro visualization of the inner ear tissues as well as for evaluation of the electrode damage and/or surgical insertion trauma during implantation of the cochlear implant electrodes. This technique can greatly aid in design and development of new cochlear implant electrodes and is applicable for temporal bone studies. The main advantage of micro-CT is the practically artefact-free preparation of the samples and the possibility of evaluation of the interesting parameters along the whole insertion depth of the electrode. This paper presents the results of the first application of micro-CT for visualization of the inner ear structures in human temporal bones and for evaluation of the surgical positioning of the cochlear implant electrodes relative to the intracochlear soft tissues.

  6. Carbon offers advantages as implant material in human body

    NASA Technical Reports Server (NTRS)

    Benson, J.

    1969-01-01

    Because of such characteristics as high strength and long-term biocompatability, aerospace carbonaceous materials may be used as surgical implants to correct pathological conditions in the body resulting from disease or injury. Examples of possible medical uses include bone replacement, implantation splints and circulatory bypass implants.

  7. Role of clinician's experience and implant design on implant stability. An ex vivo study in artificial soft bones.

    PubMed

    Romanos, Georgios E; Basha-Hijazi, Abdulaziz; Gupta, Bhumija; Ren, Yan-Fang; Malmstrom, Hans

    2014-04-01

    Clinical experience in implant placement is important in order to prevent implant failures. However, the implant design affects the primary implant stability (PS) especially in poor quality bones. Therefore, the aim of this study was to compare the effect of clinician surgical experience on PS, when placing different type of implant designs. A total of 180 implants (90 parallel walled-P and 90 tapered-T) were placed in freshly slaughtered cow ribs. Bone quality was evaluated by two examiners during surgery and considered as 'type IV' bone. Implants (ø 5 mm, length: 15 mm, Osseotite, BIOMET 3i, Palm Beach Gardens, FL, USA) were placed by three different clinicians (master/I, good/II, non-experienced/III, under direct supervision of a manufacturer representative; 30 implants/group). An independent observer assessed the accuracy of placement by resonance frequency analysis (RFA) with implant stability quotient (ISQ) values. Two-way analysis of variance (ANOVA) and Tukey's post hoc test were used to detect the surgical experience of the clinicians and their interaction and effects of implant design on the PS. All implants were mechanically stable. The mean ISQ values were: 49.57(± 18.49) for the P-implants and 67.07(± 8.79) for the T-implants. The two-way ANOVA showed significant effects of implant design (p < .0001), clinician (p < .0001), and their interaction (p < .0001). The Tukey's multiple comparison test showed significant differences in RFA for the clinician group I/II (p = .015) and highly significant (p < .0001) between I/III and II/III. The P-implants presented (for I, II, and III) mean ISQ values 31.25/49.18/68.17 and the T-implants showed higher ISQ values, 70.15/62.08/68.98, respectively. Clinicians I and II did not show extreme differences for T-implants (p = .016). In contrast, clinician III achieved high ISQ values using P- and T-implants following the exact surgical protocol based on the manufacturer guidelines. T-implants provided high stability for experienced clinicians compared with P-implants. T-implants achieved greater PS than the P-implants. All clinicians consistently achieved PS; however, experienced clinicians achieved higher ISQ values with T-implants in poor quality bone. © 2012 Wiley Periodicals, Inc.

  8. 3D printing and modelling of customized implants and surgical guides for non-human primates.

    PubMed

    Chen, Xing; Possel, Jessy K; Wacongne, Catherine; van Ham, Anne F; Klink, P Christiaan; Roelfsema, Pieter R

    2017-07-15

    Primate neurobiologists use chronically implanted devices such as pedestals for head stabilization and chambers to gain access to the brain and study its activity. Such implants are skull-mounted, and made from a hard, durable material, such as titanium. Here, we present a low-cost method of creating customized 3D-printed cranial implants that are tailored to the anatomy of individual animals. We performed pre-surgical computed tomography (CT) and magnetic resonance (MR) scans to generate three-dimensional (3D) models of the skull and brain. We then used 3D modelling software to design implantable head posts, chambers, and a pedestal anchorage base, as well as craniotomy guides to aid us during surgery. Prototypes were made from plastic or resin, while implants were 3D-printed in titanium. The implants underwent post-processing and received a coating of osteocompatible material to promote bone integration. Their tailored fit greatly facilitated surgical implantation, and eliminated the gap between the implant and the bone. To date, our implants remain robust and well-integrated with the skull. Commercial-off-the-shelf solutions typically come with a uniform, flat base, preventing them from sitting flush against the curved surface of the skull. This leaves gaps for fluid and tissue ingress, increasing the risk of microbial infection and tissue inflammation, as well as implant loss. The use of 3D printing technology enabled us to quickly and affordably create unique, complex designs, avoiding the constraints levied by traditional production methods, thereby boosting experimental success and improving the wellbeing of the animals. Copyright © 2017 The Author(s). Published by Elsevier B.V. All rights reserved.

  9. Simultaneous versus sequential bilateral cochlear implants in adults: Cost analysis in a US setting.

    PubMed

    Trinidade, Aaron; Page, Joshua C; Kennett, Sarah W; Cox, Matthew D; Dornhoffer, John L

    2017-11-01

    From a purely surgical efficiency point of view, simultaneous cochlear implantation (SimCI) is more cost-effective than sequential cochlear implantation (SeqCI) when total direct costs are considered (implant and hospital costs). However, in a setting where only SeqCI is practiced and a proportion of initially unilaterally implanted patients do not progress to a second implant, this may not be the case, especially when audiological costs are factored in. We present a cost analysis of such a scenario as would occur in our institution. Retrospective review and cost analysis. Between 2005 and 2015, 370 patients fulfilled the audiological criteria for bilateral implantation. Of those, 267 (72.1%) underwent unilateral cochlear implantation only, 101 (27.3%) progressed to SeqCI, and two underwent SimCI. The total hospital, surgical, and implant costs, and initial implant stimulation series audiological costs between August 2015 and August 2016 (29 adult patients) were used in this analysis. The total hospital, surgical, and implant costs for this period was $2,731,360.42. Based on previous local trends, if a projected eight (27.3%) of these patients decide to progress to SeqCI, this will cost an additional $750,811.04, resulting in an overall total of $3,482,171.46 for these 29 patients. Had all 29 undergone SimCI, the total projected cost would have been $3,332,991.75, representing a total potential saving of $149,179.67 (4.3%). In institutions where only SeqCI is allowed in adults, overall patient management may cost marginally more than if SimCI were practiced. This will be of interest to CI programs and health insurance companies. 4. Laryngoscope, 127:2615-2618, 2017. © 2017 The American Laryngological, Rhinological and Otological Society, Inc.

  10. 75 FR 52472 - Spectrum Requirements for Advanced Medical Technologies

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-26

    ... requires a ``Commission- approved human body simulator and test technique,'' fails to provide sufficient... therapeutic purposes in humans. In the MedRadio Order, the Commission also adopted service and technical rules... devices--the more flexible MedRadio rules accommodate body-worn as well as implanted medical devices...

  11. Application of digital diagnostic impression, virtual planning, and computer-guided implant surgery for a CAD/CAM-fabricated, implant-supported fixed dental prosthesis: a clinical report.

    PubMed

    Stapleton, Brandon M; Lin, Wei-Shao; Ntounis, Athanasios; Harris, Bryan T; Morton, Dean

    2014-09-01

    This clinical report demonstrated the use of an implant-supported fixed dental prosthesis fabricated with a contemporary digital approach. The digital diagnostic data acquisition was completed with a digital diagnostic impression with an intraoral scanner and cone-beam computed tomography with a prefabricated universal radiographic template to design a virtual prosthetically driven implant surgical plan. A surgical template fabricated with computer-aided design and computer-aided manufacturing (CAD/CAM) was used to perform computer-guided implant surgery. The definitive digital data were then used to design the definitive CAD/CAM-fabricated fixed dental prosthesis. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  12. Complications leading to surgical revision in implantable cardioverter defibrillator patients: comparison of patients with single-chamber, dual-chamber, and biventricular devices.

    PubMed

    Duray, Gabor Z; Schmitt, Joern; Cicek-Hartvig, Sule; Hohnloser, Stefan H; Israel, Carsten W

    2009-03-01

    Implantable cardioverter defibrillator (ICD) technology has become more complex, particularly with respect to biventricular resynchronization devices. The incidence of hardware-related complications in single (SC)-, dual (DC)-, and triple (BiV)-chamber devices requiring surgical revision has not been investigated systematically. We analysed data from consecutive ICD recipients implanted between January 2000 and December 2007 with respect to the need of surgical re-intervention for device- or lead-related complications. Generator exchanges due to normal battery depletion were not considered. From 816 patients (81% male, 69% ischaemic cardiomyopathy, 48% secondary prevention ICDs) followed for 31 +/- 24 months (2118 cumulative patient-years), 98 patients underwent 110 revisions (5.2% per patient-year). Complications included lead-related revision procedures in 81 cases and generator-related problems in 29 cases. The annual incidence of surgical revision due to complications was 11.8% in BiV compared with 4.9% in SC and 4.1% in DC patients (P = 0.002). This higher revision rate was mainly caused by lead-related complications. Implantation of a BiV system was an independent risk factor of the need for surgical revision (relative risk 2.37, 95% confidence interval 1.38-4.04). Even with long-lasting operator experience, complications requiring surgical revision remain a clinically important problem of ICD therapy. The incidence of complications is significantly higher in BiV resynchronization devices than in SC and DC systems.

  13. Surgical Tooth Implants, Combat and Field.

    DTIC Science & Technology

    1985-11-15

    development of dental implantology must not be overlooked. The early stages of this project clearly defined that rigid fixation of an implant device...block number) .-... This report summarizes progress on a long-ter implant study of a serrated ceramic dental implant designed for fresh extraction...implant, post and core and crown, are conventional metal materials, A series of graded dental implants have been produced to provide an interference fit

  14. Immediate loading of four implants (BTLock®) in the maxilla and provisional restoration with guide-surgery (SimPlant, Materialise®): case report

    PubMed Central

    SPINELLI, D.; DE VICO, G.; SCHIAVETTI, R.; BONINO, M.; POZZI, A.; BOLLERO, P.; BARLATTANI, A.

    2010-01-01

    SUMMARY The severe atrophy of the jaws are a challenging therapeutic problem, since the increase in bone is necessary to allow the placement of a sufficient number of implants. Combining immediate functionalization with the concept of guided surgery they combine the advantages offered by the innovative surgical and prosthetic implant technique (All-on-Four®) with those of computer-assisted planning in cases of severe bone atrophy. The method used in this case report, combines these two concepts in a surgical and prosthetic protocol safe and effective for the immediate function of 4 implants to support a fixed prosthesis in completely edentulous subjects. The integration of technology with immediate function with the concept of computer-guided surgery for implant placement and rehabilitation of completely edentulous jaws is now a predictable treatment modality with implant survival comparable to the traditional protocols. PMID:23285381

  15. New Criteria of Indication and Selection of Patients to Cochlear Implant

    PubMed Central

    Sampaio, André L. L.; Araújo, Mercêdes F. S.; Oliveira, Carlos A. C. P.

    2011-01-01

    Numerous changes continue to occur in cochlear implant candidacy. In general, these have been accompanied by concomitant and satisfactory changes in surgical techniques. Together, this has advanced the utility and safety of cochlear implantation. Most devices are now approved for use in patients with severe to profound unilateral hearing loss rather then the prior requirement of a bilateral profound loss. Furthermore, studies have begun utilizing short electrode arrays for shallow insertion in patients with considerable low-frequency residual hearing. This technique will allow the recipient to continue to use acoustically amplified hearing for the low frequencies simultaneously with a cochlear implant for the high frequencies. The advances in design of, and indications for, cochlear implants have been matched by improvements in surgical techniques and decrease in complications. The resulting improvements in safety and efficacy have further encouraged the use of these devices. This paper will review the new concepts in the candidacy of cochlear implant. Medline data base was used to search articles dealing with the following topics: cochlear implant in younger children, cochlear implant and hearing preservation, cochlear implant for unilateral deafness and tinnitus, genetic hearing loss and cochlear implant, bilateral cochlear implant, neuropathy and cochlear implant and neural plasticity, and the selection of patients for cochlear implant. PMID:22013448

  16. A Review of the Ahmed Glaucoma Valve Implant and Comparison with Other Surgical Operations.

    PubMed

    Riva, Ivano; Roberti, Gloria; Katsanos, Andreas; Oddone, Francesco; Quaranta, Luciano

    2017-04-01

    The Ahmed glaucoma valve (AGV) is a popular glaucoma drainage implant used for the control of intraocular pressure in patients with glaucoma. While in the past AGV implantation was reserved for glaucoma patients poorly controlled after one or more filtration procedures, mounting evidence has recently encouraged its use as a primary surgery in selected cases. AGV has been demonstrated to be safe and effective in reducing intraocular pressure in patients with primary or secondary refractory glaucoma. Compared to other glaucoma surgeries, AGV implantation has shown favorable efficacy and safety. The aim of this article is to review the results of studies directly comparing AGV with other surgical procedures in patients with glaucoma.

  17. Inferior Alveolar Nerve Lateralization and Transposition for Dental Implant Placement. Part I: a Systematic Review of Surgical Techniques

    PubMed Central

    Juodzbalys, Gintaras

    2015-01-01

    ABSTRACT Objectives The purpose of this first part of a two-part series was to review the literature concerning the indications, contraindications, advantages, disadvantages and surgical techniques of the lateralization and transposition of the inferior alveolar nerve, followed by the placement of an implant in an edentulous atrophic posterior mandible. Material and Methods A comprehensive review of the current literature was conducted according to the PRISMA guidelines by accessing the NCBI PubMed and PMC database, academic sites and books. The articles were searched from January 1997 to July 2014 and comprised English-language articles that included adult patients between 18 and 80 years old with minimal residual bone above the mandibular canal who had undergone inferior alveolar nerve (IAN) repositioning with a minimum 6 months of follow-up. Results A total of 16 studies were included in this review. Nine were related to IAN transposition, 4 to IAN lateralization and 3 to both transposition and lateralization. Implant treatment results and complications were presented. Conclusions Inferior alveolar nerve lateralization and transposition in combination with the installation of dental implants is sometimes the only possible procedure to help patients to obtain a fixed prosthesis, in edentulous atrophic posterior mandibles. With careful pre-operative surgical and prosthetic planning, imaging, and extremely precise surgical technique, this procedure can be successfully used for implant placement in edentulous posterior mandibular segments. PMID:25937873

  18. A new surgical method for penile girth enhancement.

    PubMed

    Li, Xiaoge; Tao, Ling; Cao, Chuan; Shi, Haishan; Li, Le; Chen, Liang; Li, Shirong

    2015-01-01

    We developed a new surgical model of penile girth enhancement in dog, with minimal damage, fewer complications, and high success rate, to enable the experimental investigation of penile implants. We obtained materials for penile girth enhancement by processing the pericardium and blood vessel wall collected from pigs. Incisions were made at the penile bulb for the implantation of the materials, and facilitate observation and data collection, based on the anatomical features of dog's penis. We measured the girth of the flaccid penis before and after the operation, and erectile function at 1-month postoperation. In addition to evaluation of recovery from the incision and local pathological changes, ultrasonic examination was performed to monitor the long-term changes associated with implantation. The mean girth of the flaccid penis significantly increased from 7.37±0.40 cm before the operation, to 8.70±0.56 cm postoperation. Dogs resumed normal mating at 1 month after the operation, without any significant change in the mating time. Ultrasonic examination clearly illustrated the implants, and helped in the measurement of the distance between the materials and the baculum. Chinese Rural dog is a promising animal model for penile girth enhancement surgery. The findings demonstrated that surgical implantation into penile bulb was associated with less damage, faster postoperative recovery, and higher success. For the first time, ultrasonic examination provided objective data on the surgical outcomes of penile girth enhancement.

  19. Surgery without papilla incision: tunneling flap procedures in plastic periodontal and implant surgery.

    PubMed

    Zuhr, Otto; Rebele, Stephan F; Cheung, Stefani L; Hürzeler, Markus B

    2018-06-01

    Diverse clinical advancements, together with some relevant technical innovations, have led to an increase in popularity of tunneling flap procedures in plastic periodontal and implant surgery in the recent past. This trend is further promoted by the fact that these techniques have lately been introduced to a considerably expanded range of indications. While originally described for the treatment of gingival recession-type defects, tunneling flap procedures may now be applied successfully in a variety of clinical situations in which augmentation of the soft tissues is indicated in the esthetic zone. Potential clinical scenarios include surgical thickening of thin buccal gingiva or peri-implant mucosa, alveolar ridge/socket preservation and implant second-stage surgery, as well as soft-tissue ridge augmentation or pontic site development. In this way, tunneling flap procedures developed from a technique, originally merely intended for surgical root coverage, into a capacious surgical conception in plastic periodontal and implant surgery. The purpose of this article is to provide a comprehensive overview on tunneling flap procedures, to introduce the successive development of the approach along with underlying ideas on surgical wound healing and to present contemporary clinical scenarios in step-by-step photograph-illustrated sequences, which aim to provide clinicians with guidance to help them integrate tunneling flap procedures into their daily clinical routine. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  20. Implant-Retained Obturator for an Edentulous Patient with a Hemimaxillectomy Defect Complicated with Microstomia

    PubMed Central

    2016-01-01

    Patient. A 68-year-old man was operated on for squamous cell carcinoma (T3N3M0) of the maxilla creating the hemimaxillary surgical defect on right side. The remaining arch was completely edentulous. There was remarkable limitation in the oral opening with reduced perimeter of the oral cavity due to radiation and surgical scar contracture. This article describes prosthetic rehabilitation by modifying the design of the obturator and achieving the retention with dental implant. Discussion. Severe limitation in the oral opening may occur in clinical situations following the postsurgical management of oral and maxillofacial defects. The prosthetic rehabilitation of the surgical defect in such patients becomes a challenging task due to limited access to the oral cavity. This challenge becomes even more difficult if the patient is edentulous and there are no teeth to gain the retention, stability, and support. Conclusion. In severe microstomia prosthesis insertion and removal can be achieved with modification of the maximum width of the prosthesis. Dental implant retention is useful treatment option in edentulous patients with maxillary surgical defect provided that sufficient bone volume and accessibility are there for implant placement. PMID:27843652

  1. Effectiveness of enamel matrix derivative on the clinical and microbiological outcomes following surgical regenerative treatment of peri-implantitis. A randomized controlled trial.

    PubMed

    Isehed, Catrine; Holmlund, Anders; Renvert, Stefan; Svenson, Björn; Johansson, Ingegerd; Lundberg, Pernilla

    2016-10-01

    This randomized clinical trial aimed at comparing radiological, clinical and microbial effects of surgical treatment of peri-implantitis alone or in combination with enamel matrix derivative (EMD). Twenty-six subjects were treated with open flap debridement and decontamination of the implant surfaces with gauze and saline preceding adjunctive EMD or no EMD. Bone level (BL) change was primary outcome and secondary outcomes were changes in pocket depth (PD), plaque, pus, bleeding and the microbiota of the peri-implant biofilm analyzed by the Human Oral Microbe Identification Microarray over a time period of 12 months. In multivariate modelling, increased marginal BL at implant site was significantly associated with EMD, the number of osseous walls in the peri-implant bone defect and a Gram+/aerobic microbial flora, whereas reduced BL was associated with a Gram-/anaerobic microbial flora and presence of bleeding and pus, with a cross-validated predictive capacity (Q(2) ) of 36.4%. Similar, but statistically non-significant, trends were seen for BL, PD, plaque, pus and bleeding in univariate analysis. Adjunctive EMD to surgical treatment of peri-implantitis was associated with prevalence of Gram+/aerobic bacteria during the follow-up period and increased marginal BL 12 months after treatment. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  2. Implementing AORN recommended practices for prevention of retained surgical items.

    PubMed

    Goldberg, Judith L; Feldman, David L

    2012-02-01

    Retention of a surgical item is a preventable event that can result in patient injury. AORN's "Recommended practices for prevention of retained surgical items" emphasizes the importance of using a multidisciplinary approach for prevention. Procedures should include counts of soft goods, needles, miscellaneous items, and instruments, and efforts should be made to prevent retention of fragments of broken devices. If a count discrepancy occurs, the perioperative team should follow procedures to locate the missing item. Perioperative leaders may consider the use of adjunct technologies such as bar-code scanning, radio-frequency detection, and radio-frequency identification. Ambulatory and hospital patient scenarios are included to exemplify appropriate strategies for preventing retained surgical items. Copyright © 2012 AORN, Inc. Published by Elsevier Inc. All rights reserved.

  3. Nanoscale Surface Modifications of Orthopaedic Implants: State of the Art and Perspectives

    PubMed Central

    Staruch, RMT; Griffin, MF; Butler, PEM

    2016-01-01

    Background: Orthopaedic implants such as the total hip or total knee replacement are examples of surgical interventions with postoperative success rates of over 90% at 10 years. Implant failure is associated with wear particles and pain that requires surgical revision. Improving the implant - bone surface interface is a key area for biomaterial research for future clinical applications. Current implants utilise mechanical, chemical or physical methods for surface modification. Methods: A review of all literature concerning the nanoscale surface modification of orthopaedic implant technology was conducted. Results: The techniques and fabrication methods of nanoscale surface modifications are discussed in detail, including benefits and potential pitfalls. Future directions for nanoscale surface technology are explored. Conclusion: Future understanding of the role of mechanical cues and protein adsorption will enable greater flexibility in surface control. The aim of this review is to investigate and summarise the current concepts and future directions for controlling the implant nanosurface to improve interactions. PMID:28217214

  4. The Efficacy of Ultraviolet Radiation for Sterilizing Tools Used for Surgically Implanting Transmitters into Fish

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Walker, Ricardo W.; Markillie, Lye Meng; Colotelo, Alison HA

    Telemetry is frequently used to examine the behavior of fish, and the transmitters used are normally surgically implanted into the coelom of fish. Implantation requires the use of surgical tools such as scalpels, forceps, needle holders, and sutures. When several fish are implanted consecutively for large telemetry studies, it is common for surgical tools to be sterilized or, at minimum, disinfected between each use so that pathogens that may be present are not spread among fish. However, autoclaving tools can take a long period of time, and chemical sterilants or disinfectants can be harmful to both humans and fish andmore » have varied effectiveness. Ultraviolet (UV) radiation is commonly used to disinfect water in aquaculture facilities. However, this technology has not been widely used to sterilize tools for surgical implantation of transmitters in fish. To determine its efficacy for this application, Pacific Northwest National Laboratory researchers used UV radiation to disinfect surgical tools (i.e., forceps, needle holder, stab scalpel, and suture) that were exposed to one of four aquatic organisms that typically lead to negative health issues for salmonids. These organisms included Aeromonas salmonicida, Flavobacterium psychrophilum, Renibacterium salmoninarum, and Saprolegnia parasitica. Surgical tools were exposed to the bacteria by dipping them into a confluent suspension of three varying concentrations (i.e., low, medium, high). After exposure to the bacterial culture, tools were placed into a mobile Millipore UV sterilization apparatus. The tools were then exposed for three different time periods—2, 5, or 15 min. S. parasitica, a water mold, was tested using an agar plate method and forceps-pinch method. UV light exposures of 5 and 15 min were effective at killing all four organisms. UV light was also effective at killing Geobacillus stearothermophilus, the organism used as a biological indicator to verify effectiveness of steam sterilizers. These techniques appear to provide a quick alternative disinfection technique for some surgical tools that is less harmful to both humans and fish while not producing chemical waste. However, we do not recommend using these methods with tools that have overlapping parts or other structures that cannot be directly exposed to UV light such as needle holders.« less

  5. Surgical and prosthetic considerations to rehabilitate an ocular defect using extraoral implants: a clinical report.

    PubMed

    de Negreiros, Wagner Araujo; Verde, Marcus Aurelio Rabelo Lima; da Silva, Antonio Materson; Pinto, Lecio Pitombeira

    2012-04-01

    This clinical report shows the use of extraoral implants to rehabilitate an ocular defect, focusing the surgical and prosthetic procedures. Using local anesthesia and a surgical template obtained from the diagnostic wax ocular pattern, two cylinder dental implants were strategically placed in the lateral aspect of the right infraorbital region. Four months later, an acrylic framework including two spherical magnets was made using plastic UCLA abutments. After casting laboratory steps, a customized silicon prosthetic appliance was fabricated from the diagnostic wax ocular pattern and attached to the Co-Cr framework, observing its profile and seating aspects. The patient was satisfied with the treatment result, due to the retention, esthetics, and adhesive-free method to anchor his ocular prostheses. © 2012 by the American College of Prosthodontists.

  6. Implant decontamination with 2% chlorhexidine during surgical peri-implantitis treatment: a randomized, double-blind, controlled trial.

    PubMed

    de Waal, Y C M; Raghoebar, G M; Meijer, H J A; Winkel, E G; van Winkelhoff, A J

    2015-09-01

    The objective of this randomized, double-blind, controlled trial was to evaluate the clinical, radiographic, and microbiological effects of implant surface decontamination with a 2% chlorhexidine (CHX) solution in comparison with a 0.12% chlorhexidine + 0.05% cetylpyridinium chloride (CPC) solution during resective surgical peri-implantitis treatment. Forty-four patients (108 implants) with peri-implantitis were treated with resective surgical treatment consisting of bone re-contouring, surface debridement and chemical decontamination, and apically repositioned flap. Patients were randomly allocated to decontamination with a 2% CHX solution (test group) or 0.12% CHX + 0.05% CPC (control group). Clinical and radiographic parameters were recorded before treatment (baseline), and at 3, 6, and 12 months after treatment. Microbiological parameters were recorded during surgery. Multilevel analysis showed no significant differences in bleeding, suppuration, probing pocket depth, and radiographic bone loss between control and test group over three follow-up measurements (3, 6, and 12 months) from baseline. Both decontamination procedures resulted in significant reductions in anaerobic bacterial counts on the implant surface, but no significant difference was noted between control and test group (mean log 3.37 ± 2.34 vs. 3.65 ± 2.87, P = 0.99). The use of a 2% CHX solution for implant surface decontamination during resective peri-implantitis therapy does not lead to improved clinical, radiographic, or microbiological results compared with a 0.12% CHX + 0.05% CPC solution. Overall, the additional use of CHX reduces anaerobic bacterial load on the implant surface better than mechanical debridement alone, but does not seem to enhance clinical treatment outcomes (ClinicalTrials.gov number NCT01852253). © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  7. A survey of the satisfaction of patients who have undergone implant surgery with and without employing a computer-guided implant surgical template

    PubMed Central

    Youk, Shin-Young; Lee, Jee-Ho; Heo, Seong-Joo; Roh, Hyun-Ki; Park, Eun-Jin; Shin, Im Hee

    2014-01-01

    PURPOSE This study aims to investigate the degree of subjective pain and the satisfaction of patients who have undergone an implant treatment using a computer-guided template. MATERIALS AND METHODS A survey was conducted for 135 patients who have undergone implant surgery with and without the use of the computer-guided template during the period of 2012 and 2013 in university hospitals, dental hospitals and dental clinics that practiced implant surgery using the computer-guided template. Likert scale and VAS score were used in the survey questions, and the independent t-test and One-Way ANOVA were performed (α=.05). RESULTS The route that the subjects were introduced to the computer-guided implant surgery using a surgical template was mostly advices by dentists, and the most common reason for which they chose to undergo such surgery was that it was accurate and safe. Most of them gave an answer that they were willing to recommend it to others. The patients who have undergone the computer-guided implant surgery felt less pain during the operation and showed higher satisfaction than those who have undergone conventional implant surgery. Among the patients who have undergone computer-guided implant surgery, those who also had prior experience of surgery without a computer-guided template expressed higher satisfaction with the former (P<.05). CONCLUSION In this study, it could be seen that the patients who have undergone computer-guided implant surgery employing a surgical template felt less pain and had higher satisfaction than those with the conventional one, and the dentist's description could provide the confidence about the safety of surgery. PMID:25352962

  8. Photodynamic therapy to treat periimplantitis.

    PubMed

    Bombeccari, Gian Paolo; Guzzi, Gianpaolo; Gualini, Federico; Gualini, Sara; Santoro, Franco; Spadari, Francesco

    2013-12-01

    : Periimplantitis is a bacterial complication after dental implants implantation. Photodynamic therapy (PDT) implies the use of low-power laser in combination with appropriate photosensitizer to increase the detoxification of the implant surfaces. Little information exists about PDT in the treatment of periimplantitis. A randomized comparative case-control study has been conducted with 20 patients and 20 controls to compare the efficacy of antimicrobial PDT versus surgical therapy in patients with periimplantitis, who have received dental implants with rough surfaces. In the surgery group, mucoperiosteal flap surgery was used with scaling on implant surfaces and debridement of granulation tissue. Microbiologic testing was evaluated before and after intervention treatment, at 12 and 24 weeks in the study subjects. Total anaerobic counts of bacteria did not differ significantly between patients assigned to receive PDT and those assigned to receive surgical therapy (mean, 95.2% and 80.85%, respectively). PDT was associated with a significant decrease in bleeding scores (P = 0.02) as well as inflammatory exudation (P = 0.001). Treatment with PDT in patients with periimplantitis was not associated with major reduction of total anaerobic bacteria on the rough surfaces of dental implants as compared with surgical therapy. A significantly lower proinflammatory index of periimplantitis was observed in the PDT group at 24 weeks of follow-up.

  9. Open flap versus flapless placement of dental implants. A randomized controlled pilot trial.

    PubMed

    Jané-Salas, Enric; Roselló-LLabrés, Xavier; Jané-Pallí, Enric; Mishra, Siddharth; Ayuso-Montero, Raúl; López-López, José

    2018-02-20

    The aim of this study was to compare the immediate postoperative period of participants rehabilitated with dental implants placed with a conventional technique or with a minimally invasive technique, without a mucoperiosteal flap elevation (flapless). Participants who needed implant placement were divided into two groups: one group was operated using a mucoperiosteal flap elevation (G_A), and the other with a flapless surgical technique (G_B). Objective clinical parameters including oral hygiene, mouth opening, inflammation (facial perimeter), surgical time and analgesic consumption, as well as subjective parameters of pain and degree of satisfaction with the procedure, were evaluated. 48 implants were placed in 30 participants (15 participants per group). Oral hygiene index, maximum interincisal opening, pain and analgesic consumption values had a significant difference between groups favoring the flapless technique at 24 h and 7 days but at the 15 days' follow-up the differences were only significant for oral hygiene and pain (P < 0.05); there were no statistically significant differences between groups in terms of facial perimeter values and surgical time (P > 0.05). Average on the degree of satisfaction was of 2.6 (SD 0.8) for G_A and 3.6 (SD 1.02) for G_B (P = 0.06). One implant placed in G_A (2.0%) failed before prosthetic loading due to mobility and pain at 3 months' follow-up. Participants operated for implant placement with flapless surgical technique go through less postoperative discomfort. Both techniques show high success rates, but to perform a flapless technique patients must be properly selected.

  10. Implantation of a new enteral stent in obstructive colorectal cancer using interventional radiology in patients over 70 years of age.

    PubMed

    Miłek, Tomasz; Ciostek, Piotr

    2015-07-01

    Colorectal cancer is the second leading cause of death due to cancer in Poland. The traditional approach to treat patients included a surgical procedure. Irrespective of the surgical method being used, surgical treatment of malignant colorectal obstruction is associated with prolonged hospitalisation, and the postoperative mortality rate is approximately 5-11%. Due to these problems, more interest has been shown in less invasive methods. Prosthesis implantation is a leading endoscopic method used currently in palliative or preoperative treatment. To compare the results of implantation of traditional stents with the results of implantation of an own stent using minimally invasive methods. Left-sided colon obstruction due to cancer was an indication for transplantation. All patients were aged over 70 years and had serious concomitant diseases. The control group included 50 patients with colorectal cancer who received traditional stents in the period 2009-2011. Our stent covers only the internal length of a tumour. It is not equipped with anti-migration flares. To minimize the risk of migration it has a system of hooks that are responsible for permanent anchorage of the stent within the tumour mass. Implantation technical and clinical success defined as effective decompression of intestinal obstruction was 100% in both groups. There were 2 cases of stent migration in the control group. It is possible to achieve a secure surgical anastomosis after intestinal decompression. Stent implantation is fast and safe thanks to the positioning system that was used. The use of labelled hooks is a secure anti-migration solution.

  11. Electromagnetic interference of cardiac rhythmic monitoring devices to radio frequency identification: analytical analysis and mitigation methodology.

    PubMed

    Ogirala, Ajay; Stachel, Joshua R; Mickle, Marlin H

    2011-11-01

    Increasing density of wireless communication and development of radio frequency identification (RFID) technology in particular have increased the susceptibility of patients equipped with cardiac rhythmic monitoring devices (CRMD) to environmental electro magnetic interference (EMI). Several organizations reported observing CRMD EMI from different sources. This paper focuses on mathematically analyzing the energy as perceived by the implanted device, i.e., voltage. Radio frequency (RF) energy transmitted by RFID interrogators is considered as an example. A simplified front-end equivalent circuit of a CRMD sensing circuitry is proposed for the analysis following extensive black-box testing of several commercial pacemakers and implantable defibrillators. After careful understanding of the mechanics of the CRMD signal processing in identifying the QRS complex of the heart-beat, a mitigation technique is proposed. The mitigation methodology introduced in this paper is logical in approach, simple to implement and is therefore applicable to all wireless communication protocols.

  12. Comparing the survival rate of juvenile Chinook salmon migrating through hydropower systems using injectable and surgical acoustic transmitters

    DOE PAGES

    Deng, Zhiqun D.; Martinez, J. J.; Li, H.; ...

    2017-02-21

    Acoustic telemetry is one of the primary technologies for studying the behavior and survival of fishes throughout the world. The size and performance of the transmitters is still the key limiting factor despite that considerable effort has been expended to understand the biological effects of implantation of acoustic transmitters in yearling and subyearling Chinook salmon. The newly developed injectable transmitter is the first active acoustic tag that can be implanted via injection instead of surgery. It also lasts more than four times longer than the commercially-available transmitters. A two-part field study was conducted to evaluate the performance of the injectablemore » transmitter and its effect on the survival of implanted fish. The injectable transmitter performed well and similarly to the other commercially-available transmitters tested. Snake River subyearling Chinook salmon smolts implanted with the injectable tag had a higher survival probability from release to each of 11 downstream detection arrays than concurrent releases of fish surgically implanted with commercially-available tags. In addition, reach-specific survival estimates were significantly higher for the injectable group in three of the eleven reaches examined. Overall, the injectable group had a 0.263 (SE = 0.017) survival probability over the entire 500 km study area compared to 0.199 (0.012) for the surgically implanted group. The differences in survival may have been caused by warm water temperatures and higher rates of infection experienced by the surgically implanted group due to the presence of sutures acting as an attachment site for pathogens. The reduction in size and ability to implant the new transmitter via injection has further reduced the tag or tagging effect bias associated with studying small fishes. As a result, the information gathered with this new technology is helping minimize the impact of dams on fish, leading to more environmentally sustainable energy systems.« less

  13. Comparing the survival rate of juvenile Chinook salmon migrating through hydropower systems using injectable and surgical acoustic transmitters

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Deng, Zhiqun D.; Martinez, J. J.; Li, H.

    Acoustic telemetry is one of the primary technologies for studying the behavior and survival of fishes throughout the world. The size and performance of the transmitters is still the key limiting factor despite that considerable effort has been expended to understand the biological effects of implantation of acoustic transmitters in yearling and subyearling Chinook salmon. The newly developed injectable transmitter is the first active acoustic tag that can be implanted via injection instead of surgery. It also lasts more than four times longer than the commercially-available transmitters. A two-part field study was conducted to evaluate the performance of the injectablemore » transmitter and its effect on the survival of implanted fish. The injectable transmitter performed well and similarly to the other commercially-available transmitters tested. Snake River subyearling Chinook salmon smolts implanted with the injectable tag had a higher survival probability from release to each of 11 downstream detection arrays than concurrent releases of fish surgically implanted with commercially-available tags. In addition, reach-specific survival estimates were significantly higher for the injectable group in three of the eleven reaches examined. Overall, the injectable group had a 0.263 (SE = 0.017) survival probability over the entire 500 km study area compared to 0.199 (0.012) for the surgically implanted group. The differences in survival may have been caused by warm water temperatures and higher rates of infection experienced by the surgically implanted group due to the presence of sutures acting as an attachment site for pathogens. The reduction in size and ability to implant the new transmitter via injection has further reduced the tag or tagging effect bias associated with studying small fishes. As a result, the information gathered with this new technology is helping minimize the impact of dams on fish, leading to more environmentally sustainable energy systems.« less

  14. Serving Deaf Students Who Have Cochlear Implants. PEPNet Tipsheet

    ERIC Educational Resources Information Center

    Searls, J. Matt, Comp.

    2010-01-01

    Cochlear implants (CIs) are complex electronic devices surgically implanted under the skin behind the ear. These devices utilize electrodes placed in the inner ear (the cochlea) to stimulate the auditory nerve of individuals with significant permanent hearing loss. Cochlear implants may not be suitable for everyone. They are designed to provide…

  15. A system for gathering small mammal data

    Treesearch

    Robert D. Neely; Robert W. Campbell

    1973-01-01

    As an aid to studying vertebrate predators of the gypsy moth, a radio telemetry system was designed to detect the death of small mammals and facilitate recovery of the remains. An intraperitoneally implanted radio transmitter is triggered by the drop in body temperature when the animal dies. The device was tested in white-footed mice.

  16. Esthetics of Flapless Single-Tooth Implants in the Anterior Maxilla Using Guided Surgery: Association of Three-Dimensional Accuracy and Pink Esthetic Score.

    PubMed

    Fürhauser, Rudolf; Mailath-Pokorny, Georg; Haas, Robert; Busenlechner, Dieter; Watzek, Georg; Pommer, Bernhard

    2015-10-01

    Flapless implant placement using surgical templates may guarantee predictable and esthetic results provided that preplanned implant positions are transfered precisely into surgical reality. The study aims to investigate the effect of three-dimensional accuracy in guided implant surgery on the esthetic outcome of single-tooth implants in the anterior maxilla. Single-tooth implants for delayed replacement of upper incisors were inserted in 27 patients using stereolithographic templates. Superimposition of postoperative cone beam computed tomography (CBCT) scans allowed assessment of positional inaccuracy at the implant shoulder and apex, as well as angular deviation. Objective evaluation of implant esthetics was performed after a mean follow-up of 2.3 years using the Pink Esthetic Score (PES). Mean deviation between planned and actual implant position was 0.84 mm at the implant shoulder and significantly correlated to average PES of 12 (p = .031). Inaccuracy toward the buccal side was most frequent (70%). Deviations  ≥  0.8  mm resulted in significantly worse implant esthetics (median PES: 9.5, interquartile range [IQR]: 8-11) compared with more accurate implant positions (median PES: 13, IQR: 12-13, p = .039). Positional inaccuracy is low in guided implant surgery, but may however significantly compromise implant esthetics in the anterior maxilla. © 2014 Wiley Periodicals, Inc.

  17. Advances in lens implant technology

    PubMed Central

    Kampik, Anselm; Dexl, Alois K.; Zimmermann, Nicole; Glasser, Adrian; Baumeister, Martin; Kohnen, Thomas

    2013-01-01

    Cataract surgery is one of the oldest and the most frequent outpatient clinic operations in medicine performed worldwide. The clouded human crystalline lens is replaced by an artificial intraocular lens implanted into the capsular bag. During the last six decades, cataract surgery has undergone rapid development from a traumatic, manual surgical procedure with implantation of a simple lens to a minimally invasive intervention increasingly assisted by high technology and a broad variety of implants customized for each patient’s individual requirements. This review discusses the major advances in this field and focuses on the main challenge remaining – the treatment of presbyopia. The demand for correction of presbyopia is increasing, reflecting the global growth of the ageing population. Pearls and pitfalls of currently applied methods to correct presbyopia and different approaches under investigation, both in lens implant technology and in surgical technology, are discussed. PMID:23413369

  18. Short Implants: New Horizon in Implant Dentistry.

    PubMed

    Jain, Neha; Gulati, Manisha; Garg, Meenu; Pathak, Chetan

    2016-09-01

    The choice of implant length is an essential factor in deciding the survival rates of these implants and the overall success of the prosthesis. Placing an implant in the posterior part of the maxilla and mandible has always been very critical due to poor bone quality and quantity. Long implants can be placed in association with complex surgical procedures such as sinus lift and bone augmentation. These techniques are associated with higher cost, increased treatment time and greater morbidity. Hence, there is need for a less invasive treatment option in areas of poor bone quantity and quality. Data related to survival rates of short implants, their design and prosthetic considerations has been compiled and structured in this manuscript with emphasis on the indications, advantages of short implants and critical biomechanical factors to be taken into consideration when choosing to place them. Studies have shown that comparable success rates can be achieved with short implants as those with long implants by decreasing the lateral forces to the prosthesis, eliminating cantilevers, increasing implant surface area and improving implant to abutment connection. Short implants can be considered as an effective treatment alternative in resorbed ridges. Short implants can be considered as a viable treatment option in atrophic ridge cases in order to avoid complex surgical procedures required to place long implants. With improvement in the implant surface geometry and surface texture, there is an increase in the bone implant contact area which provides a good primary stability during osseo-integration.

  19. Short Implants: New Horizon in Implant Dentistry

    PubMed Central

    Gulati, Manisha; Garg, Meenu; Pathak, Chetan

    2016-01-01

    The choice of implant length is an essential factor in deciding the survival rates of these implants and the overall success of the prosthesis. Placing an implant in the posterior part of the maxilla and mandible has always been very critical due to poor bone quality and quantity. Long implants can be placed in association with complex surgical procedures such as sinus lift and bone augmentation. These techniques are associated with higher cost, increased treatment time and greater morbidity. Hence, there is need for a less invasive treatment option in areas of poor bone quantity and quality. Data related to survival rates of short implants, their design and prosthetic considerations has been compiled and structured in this manuscript with emphasis on the indications, advantages of short implants and critical biomechanical factors to be taken into consideration when choosing to place them. Studies have shown that comparable success rates can be achieved with short implants as those with long implants by decreasing the lateral forces to the prosthesis, eliminating cantilevers, increasing implant surface area and improving implant to abutment connection. Short implants can be considered as an effective treatment alternative in resorbed ridges. Short implants can be considered as a viable treatment option in atrophic ridge cases in order to avoid complex surgical procedures required to place long implants. With improvement in the implant surface geometry and surface texture, there is an increase in the bone implant contact area which provides a good primary stability during osseo-integration. PMID:27790598

  20. [Multifocal intraocular lenses. A review].

    PubMed

    Auffarth, G U; Dick, H B

    2001-02-01

    Modern cataract surgery has developed tremendously during the past 10-15 years. Improved surgical techniques, as well as improved implant materials and designs, have enlarged patient profiles and indications for cataract surgery. This also created much higher expectations from the patients' site. The loss of accommodation is loss of quality of life for presbyopic and especially young pseudophakic patients. Therefore cataract surgery with multifocal IOL implantation is not only of academic interest, but reflects demands and expectations of our patients. Multifocal IOLs have been implanted since 1986, starting with 2-3 zone refractive and diffractive designs. Due to surgical techniques of that time MIOL decentration and surgically induced astigmatism were possible complications. In addition reduced contrast sensitivity and increased glare were common problems of MIOL because of their optical principles. New developments in this field in recent years such as the multizonal, progressive refractive MIOL in combination with improved surgical techniques have overcome those initial problems. Therefore, modern multifocal IOLs can be considered not only for correction of aphakia but also for refractive purposes.

  1. Global Convergence on the Bioethics of Surgical Implants

    PubMed Central

    Monlezun, Dominique J.

    2015-01-01

    The increasing globalization of mankind with pluralistic belief systems necessitates physicians by virtue of their profession to partner with bioethics for soundly applying emerging knowledge and technologies for the best use of the patient. A subfield within medicine in which this need is acutely felt is that of surgical implants. Within this subfield such recent promising ethics and medicine partnerships include the International Tissue Engineering Research Association and UNESCO Chair in Bioethics and Human Rights' International Code of Ethics. In this paper, we provide an overview of the emerging human rights framework from bioethics and international law, discussion of key framework principles, their application to the current surgical challenge of implantation of surgical mesh for prolapse, and conclusions and recommendations. Such discussions are meant to facilitate true quality improvement in patient care by ensuring the exciting technologies and medical practices emerging new daily are accompanied by an equal commitment of physicians to ethically provide their services for the chief end of the patient's good. PMID:25973426

  2. Global convergence on the bioethics of surgical implants.

    PubMed

    Garcia, Alberto; Monlezun, Dominique J

    2015-01-01

    The increasing globalization of mankind with pluralistic belief systems necessitates physicians by virtue of their profession to partner with bioethics for soundly applying emerging knowledge and technologies for the best use of the patient. A subfield within medicine in which this need is acutely felt is that of surgical implants. Within this subfield such recent promising ethics and medicine partnerships include the International Tissue Engineering Research Association and UNESCO Chair in Bioethics and Human Rights' International Code of Ethics. In this paper, we provide an overview of the emerging human rights framework from bioethics and international law, discussion of key framework principles, their application to the current surgical challenge of implantation of surgical mesh for prolapse, and conclusions and recommendations. Such discussions are meant to facilitate true quality improvement in patient care by ensuring the exciting technologies and medical practices emerging new daily are accompanied by an equal commitment of physicians to ethically provide their services for the chief end of the patient's good.

  3. Biomechanical Three-Dimensional Finite Element Analysis of Single Implant-Supported Prostheses in the Anterior Maxilla, with Different Surgical Techniques and Implant Types.

    PubMed

    Verri, Fellippo Ramos; Santiago, Joel Ferreira; Almeida, Daniel Augusto; de Souza Batista, Victor Eduardo; Araujo Lemos, Cleidiel Aparecido; Mello, Caroline Cantieri; Pellizzer, Eduardo Piza

    The aim of this study was to use three-dimensional finite element analysis to analyze the stress distribution transferred by single implant-supported prostheses placed in the anterior maxilla using different connections (external hexagon, internal hexagon, or Morse taper), inclinations of the load (0, 30, or 60 degrees), and surgical techniques for placement (monocortical/conventional, bicortical, or bicortical with nasal floor elevation). Nine models representing a bone block of this region were simulated by computer-aided design software (InVesalius, Rhinoceros, SolidWorks). Each model received one implant, which supported a cemented metalloceramic crown. Using FEMAP software, finite elements were discretized while simulating a 178-N load at 0, 30, and 60 degrees relative to the long axis of the implant. The problem was solved in NEi Nastran software, and postprocessing was performed in FEMAP. Von Mises stress and maximum principal stress maps were made. The von Mises stress analysis revealed that stress increased with increasing inclination of the load, from 0 to 30 to 60 degrees. Morse taper implants showed less stress concentration around the cervical and apical areas of the implant. The bicortical technique, associated or not with nasal floor elevation, contributed to decreasing the stress concentration in the apical area of the implant. Maximum principal stress analysis showed that the increase in inclination was proportional to the increase in stress on the bone tissue in the cervical area. Lower stress concentrations in the cortical bone were obtained with Morse taper implants and the bicortical technique compared with other connections and surgical techniques, respectively. Increasing the inclination of the applied force relative to the long axis of the implant tended to overload the peri-implant bone tissue and the internal structure of the implants. The Morse taper connection and bicortical techniques seemed to be more favorable than other connections or techniques, respectively, for restoring the anterior maxilla.

  4. Implementing Capsule Representation in a Total Hip Dislocation Finite Element Model

    PubMed Central

    Stewart, Kristofer J; Pedersen, Douglas R; Callaghan, John J; Brown, Thomas D

    2004-01-01

    Previously validated hardware-only finite element models of THA dislocation have clarified how various component design and surgical placement variables contribute to resisting the propensity for implant dislocation. This body of work has now been enhanced with the incorporation of experimentally based capsule representation, and with anatomic bone structures. The current form of this finite element model provides for large deformation multi-body contact (including capsule wrap-around on bone and/or implant), large displacement interfacial sliding, and large deformation (hyperelastic) capsule representation. In addition, the modular nature of this model now allows for rapid incorporation of current or future total hip implant designs, accepts complex multi-axial physiologic motion inputs, and outputs case-specific component/bone/soft-tissue impingement events. This soft-tissue-augmented finite element model is being used to investigate the performance of various implant designs for a range of clinically-representative soft tissue integrities and surgical techniques. Preliminary results show that capsule enhancement makes a substantial difference in stability, compared to an otherwise identical hardware-only model. This model is intended to help put implant design and surgical technique decisions on a firmer scientific basis, in terms of reducing the likelihood of dislocation. PMID:15296198

  5. Accuracy of three different types of stereolithographic surgical guide in implant placement: an in vitro study.

    PubMed

    Turbush, Sarah Katherine; Turkyilmaz, Ilser

    2012-09-01

    Precise treatment planning before implant surgery is necessary to identify vital structures and to ensure a predictable restorative outcome. The purpose of this study was to compare the accuracy of implant placement by using 3 different types of surgical guide: bone-supported, tooth-supported, and mucosa-supported. Thirty acrylic resin mandibles were fabricated with stereolithography (SLA) based on data from the cone beam computerized tomography (CBCT) scan of an edentulous patient. Ten of the mandibles were modified digitally before fabrication with the addition of 4 teeth, and 10 of the mandibles were modified after fabrication with soft acrylic resin to simulate mucosa. Each acrylic resin mandible had 5 implants virtually planned in a 3-D software program. A total of 150 implants were planned and placed by using SLA guides. Presurgical and postsurgical CBCT scans were superimposed to compare the virtual implant placement with the actual implant placement. For statistical analyses, a linear mixed models approach and t-test with the 2-sided alpha level set at .016 were used. All reported P values were adjusted by the Dunn-Sidak method to control the Type I error rate across multiple pairwise comparisons. The mean angular deviation of the long axis between the planned and placed implants was 2.2 ±1.2 degrees; the mean deviations in linear distance between the planned and placed implants were 1.18 ±0.42 mm at the implant neck and 1.44 ±0.67 mm at the implant apex for all 150 implants. After the superimposition procedure, the angular deviation of the placed implants was 2.26 ±1.30 degrees with the tooth-supported, 2.17 ±1.02 degrees with the bone-supported, and 2.29 ±1.28 degrees with the mucosa-supported SLA guide. The mean deviations in linear distance between the planned and placed implants at the neck and apex were 1.00 ±0.33 mm and 1.15 ±0.42 mm for the tooth-supported guides; 1.08 ±0.33 mm and 1.53 ±0.90 mm for the bone-supported guides; and 1.47 ±0.43 mm and 1.65 ±0.48 mm for the mucosa-supported SLA surgical guides. The results of this study show that stereolithographic surgical guides may be reliable in implant placement and that: 1) there was no statistically significant difference among the 3 types of guide when comparing angular deviation and 2) mucosa-supported guides were less accurate than both tooth-supported and bone-supported guides for linear deviation at the implant neck and apex. Copyright © 2012 The Editorial Council of the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.

  6. Assessment of wrought ASTM F1058 cobalt alloy properties for permanent surgical implants.

    PubMed

    Clerc, C O; Jedwab, M R; Mayer, D W; Thompson, P J; Stinson, J S

    1997-01-01

    The behavior of the ASTM F1058 wrought cobalt-chromium-nickel-molybdenum-iron alloy (commonly referred to as Elgiloy or Phynox) is evaluated in terms of mechanical properties, magnetic resonance imaging, corrosion resistance, and biocompatibility. The data found in the literature, the experimental corrosion and biocompatibility results presented in this article, and its long track record as an implant material demonstrate that the cobalt superalloy is an appropriate material for permanent surgical implants that require high yield strength and fatigue resistance combined with high elastic modulus, and that it can be safely imaged with magnetic resonance.

  7. Retained broken implants in the craniomaxillofacial skeleton.

    PubMed

    Nallathamby, Vigneswaran; Lee, Hanjing; Lin, Yap Yan; Lim, Jane; Ong, Wei Chen; Lim, Thiam-Chye

    2014-06-01

    Facial fracture patients are seen in a Level 1 trauma hospital. In our institution, we manage many patients with facial fractures and carry out more than 150 surgical procedures every year. Open reduction and internal fixation is our management of choice. All surgical procedures involve drilling of bone and implant insertion to keep the fractured bones in an anatomically reduced position to aid healing. Occasionally, drill bits used to create the pilot hole break and are embedded in the bone. We present a situation in which such an incident occurred and review the literature on retained broken implants and devices.

  8. Surface and local electronic structure modification of MgO film using Zn and Fe ion implantation

    NASA Astrophysics Data System (ADS)

    Singh, Jitendra Pal; Lim, Weon Cheol; Lee, Jihye; Song, Jonghan; Lee, Ik-Jae; Chae, Keun Hwa

    2018-02-01

    Present work is motivated to investigate the surface and local electronic structure modifications of MgO films implanted with Zn and Fe ions. MgO film was deposited using radio frequency sputtering method. Atomic force microscopy measurements exhibit morphological changes associated with implantation. Implantation of Fe and Zn ions leads to the reduction of co-ordination geometry of Mg2+ ions in host lattice. The effect is dominant at bulk of film rather than surface as the large concentration of implanted ions resides inside bulk. Moreover, the evidences of interaction among implanted ions and oxygen are not being observed using near edge fine structure measurements.

  9. Sirviendo a los estudiantes sordos que tienen Los implantes cocleares. Hoja de consejos de PEPNet (Serving Deaf Students Who Have Cochlear Implants. PEPNet Tipsheet)

    ERIC Educational Resources Information Center

    Clark, Catherine

    2010-01-01

    This version of "Serving Deaf Students Who Have Cochlear Implants. PEPNet Tipsheet," written in Spanish, describes how cochlear implants (CIs) work. CIs are complex electronic devices surgically implanted under the skin behind the ear. These devices utilize electrodes placed in the inner ear (the cochlea) to stimulate the auditory nerve of…

  10. Surgical Tooth Implants, Combat and Field.

    DTIC Science & Technology

    1983-07-15

    The upper two parts of the implant (post and core and crown) are conventional dental materials, usually gold. EX) 1473 MrION Of" I POV GS IS O&SOLETE...10 Clinical Examples of Baboon Dental Implants . . . . . . . . . . . 12 Histologic Analysis of the Bone-Implant Interface . . . . . . . . 16...Aluminum Oxide Dental Implant . . . . . . . . . . 2 Figure 2. Clinical Photograph of A29 and A30 in Baboon 469 at Necropsy

  11. Effect of Antibiotic Prophylaxis on Surgical Site Infections Following Removal of Orthopedic Implants Used for Treatment of Foot, Ankle, and Lower Leg Fractures: A Randomized Clinical Trial.

    PubMed

    Backes, Manouk; Dingemans, Siem A; Dijkgraaf, Marcel G W; van den Berg, H Rogier; van Dijkman, Bart; Hoogendoorn, Jochem M; Joosse, Pieter; Ritchie, Ewan D; Roerdink, W Herbert; Schots, Judith P M; Sosef, Nico L; Spijkerman, Ingrid J B; Twigt, Bas A; van der Veen, Alexander H; van Veen, Ruben N; Vermeulen, Jefrey; Vos, Dagmar I; Winkelhagen, Jasper; Goslings, J Carel; Schepers, Tim

    2017-12-26

    Following clean (class I, not contaminated) surgical procedures, the rate of surgical site infection (SSI) should be less than approximately 2%. However, an infection rate of 12.2% has been reported following removal of orthopedic implants used for treatment of fractures below the knee. To evaluate the effect of a single dose of preoperative antibiotic prophylaxis on the incidence of SSIs following removal of orthopedic implants used for treatment of fractures below the knee. Multicenter, double-blind, randomized clinical trial including 500 patients aged 18 to 75 years with previous surgical treatment for fractures below the knee who were undergoing removal of orthopedic implants from 19 hospitals (17 teaching and 2 academic) in the Netherlands (November 2014-September 2016), with a follow-up of 6 months (final follow-up, March 28, 2017). Exclusion criteria were an active infection or fistula, antibiotic treatment, reimplantation of osteosynthesis material in the same session, allergy for cephalosporins, known kidney disease, immunosuppressant use, or pregnancy. A single preoperative intravenous dose of 1000 mg of cefazolin (cefazolin group, n = 228) or sodium chloride (0.9%; saline group, n = 242). Primary outcome was SSI within 30 days as measured by the criteria from the US Centers for Disease Control and Prevention. Secondary outcome measures were functional outcome, health-related quality of life, and patient satisfaction. Among 477 randomized patients (mean age, 44 years [SD, 15]; women, 274 [57%]; median time from orthopedic implant placement, 11 months [interquartile range, 7-16]), 470 patients completed the study. Sixty-six patients developed an SSI (14.0%): 30 patients (13.2%) in the cefazolin group vs 36 in the saline group (14.9%) (absolute risk difference, -1.7 [95% CI, -8.0 to 4.6], P = .60). Among patients undergoing surgery for removal of orthopedic implants used for treatment of fractures below the knee, a single preoperative dose of intravenous cefazolin compared with saline did not reduce the risk of surgical site infection within 30 days following implant removal. clinicaltrials.gov Identifier: NCT02225821.

  12. [Guided and computer-assisted implant surgery and prosthetic: The continuous digital workflow].

    PubMed

    Pascual, D; Vaysse, J

    2016-02-01

    New continuous digital workflow protocols of guided and computer-assisted implant surgery improve accuracy of implant positioning. The design of the future prosthesis is based on the available prosthetic space, gingival height and occlusal relationship with the opposing and adjacent teeth. The implant position and length depend on volume, density and bone quality, gingival height, tooth-implant and implant-implant distances, implant parallelism, axis and type of the future prosthesis. The crown modeled on the software will therefore serve as a guide to the future implant axis and not the reverse. The guide is made by 3D printing. The software determines surgical protocol with the drilling sequences. The unitary or plural prosthesis, modeled on the software and built before surgery, is loaded directly after implant placing, if needed. These protocols allow for a full continuity of the digital workflow. The software provides the surgeon and the dental technician a total freedom for the prosthetic-surgery guide design and the position of the implants. The prosthetic project, occlusal and aesthetic, taking the bony and surgical constraints into account, is optimized. The implant surgery is simplified and becomes less "stressful" for the patient and the surgeon. Guided and computer-assisted surgery with continuous digital workflow is becoming the technique of choice to improve the accuracy and quality of implant rehabilitation. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  13. Histopathological comparative analysis of peri-implant soft tissue response after dental implant placement with flap and flapless surgical technique. Experimental study in pigs.

    PubMed

    Vlahovic, Zoran; Markovic, Aleksa; Golubovic, Mileta; Scepanovic, Miodrag; Kalanovic, Milena; Djinic, Ana

    2015-11-01

    The aim of this study was comparing the effect of flapless vs. flap technique of implant placement on inflammation degree of peri-implant soft tissue, through histopathological analysis. The experiment was conducted on five domestic pigs. Nine weeks after tooth extraction, implants were installed. Each animal received six implants in mandible. According to split-mouth design, randomly one side was used for flapless technique using mini-incision, while on the other side, flap was raised. After 7, 14, 21, 28, and 90 days, the experimental animals were sacrificed. Samples for histopathological analyzes were taken from the buccal side of peri-implant mucosa next to the neck of implants, from three levels. The degree of inflammatory response in the peri-implant soft tissue was estimated through ordinal scores from 0 to 3. In the flap group Score 3 indicating high degree of inflammation was present from day 7 to day 21, in contrast to flapless group where Score 3 was not recorded during the entire follow-up. Three months after implantation, there were no signs of inflammation neither around flap nor around flapless implants. Flapless surgical implantation technique using mini-incision decreases peri-implant soft tissue inflammatory reaction compared with flap surgery. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  14. Teaching mandibular implant-Supported overdentures in dental schools in North America - a survey.

    PubMed

    Ben-Gal, G; Ziv, Y; Weiss, E I; Zabrovsky, A

    2017-05-01

    Mandibular two-implant overdentures are considered the minimum standard of care for edentulous patients and provide an excellent performance, as well as satisfaction to the patients. Dental schools are required to promote the teaching of current treatment options in order to enable students to master state-of-the-art procedures. The purpose of this study was to examine how the theoretical and practical aspects of mandibular two-implant overdentures are taught in dental schools in North America. Data were collected via an online questionnaire that included questions regarding the theoretical and clinical courses, surgical procedure and imaging method. Of 75 schools, 36 responded to the survey. Almost all the schools teach the subject theoretically, but it is not mandatory for students to perform in most of the schools. Only a minority (23%) of the mandibular dentures made by students are implant-supported. Almost all of the schools (94%) use two implants to support overdentures, and Locator abutment is used almost exclusively. The prevalent imaging for the surgical procedure is CT scans, although 30% of the schools use panoramic radiograph. None of the schools loads the implants immediately after surgery. Some clear trends are apparent in the current survey: the use of two implants, no use of bar connectors and delayed loading of the implants. It is likely that graduates will not have sufficient clinical skills and will need continuing education to be familiar with the required procedures, both surgical and prosthetic. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  15. Evaluating the clinical and esthetic outcome of apically positioned flap technique in augmentation of keratinized gingiva around dental implants

    PubMed Central

    Reddy, Vineela Katam; Parthasarathy, Harinath; Lochana, Priya

    2013-01-01

    Purpose: Dental implants though a successful treatment modality there exists controversies regarding the relationship between the adequacy of the keratinized gingiva (KG) and peri-implant health. The presence of an adequate amount of peri-implant KG reduces gingival inflammation and hence soft-tissue augmentation should be frequently considered. Among the various periodontal plastic surgical procedures, the apically displaced flap increases the width of keratinized tissue with reduced patient morbidity. The current study aims at evaluating the esthetic improvement in KG around dental implants applying apically positioned flap (APF) technique. Materials and Methods: A total of 10 endosseous dental implants were placed in eight systemically healthy patients. APF surgery was performed at the implant site on the buccal aspect either at the time of implant placement (one stage surgical protocol) or during the implant recovery stage (two stage surgical protocols) for increasing the width of KG and reviewed until 12 weeks post-operatively. The width of KG was evaluated at baseline and at the end of 12 weeks after surgery. Paired t-test was performed to evaluate the changes in the width of KG at baseline and at 12 weeks post-operatively. In addition, soft-tissue esthetic outcome was assessed by using visual analog scale (VAS). Results: The mean width of KG at baseline was 1.47 mm and 12 weeks post-operatively was 5.42 mm. The gain in KG from baseline was 3.95 mm with the P value of 0.000, which was highly statistically significant. The assessment of esthetic outcome using VAS gave an average score of 7.1 indicating good esthetics. Conclusion: The technique of APF yielded a significant improvement in keratinized tissue, which is both functionally and esthetically acceptable. PMID:24124297

  16. Experimental and Numerical Models of Complex Clinical Scenarios; Strategies to Improve Relevance and Reproducibility of Joint Replacement Research

    PubMed Central

    Bechtold, Joan E.; Swider, Pascal; Goreham-Voss, Curtis; Soballe, Kjeld

    2016-01-01

    This research review aims to focus attention on the effect of specific surgical and host factors on implant fixation, and the importance of accounting for them in experimental and numerical models. These factors affect (a) eventual clinical applicability and (b) reproducibility of findings across research groups. Proper function and longevity for orthopedic joint replacement implants relies on secure fixation to the surrounding bone. Technology and surgical technique has improved over the last 50 years, and robust ingrowth and decades of implant survival is now routinely achieved for healthy patients and first-time (primary) implantation. Second-time (revision) implantation presents with bone loss with interfacial bone gaps in areas vital for secure mechanical fixation. Patients with medical comorbidities such as infection, smoking, congestive heart failure, kidney disease, and diabetes have a diminished healing response, poorer implant fixation, and greater revision risk. It is these more difficult clinical scenarios that require research to evaluate more advanced treatment approaches. Such treatments can include osteogenic or antimicrobial implant coatings, allo- or autogenous cellular or tissue-based approaches, local and systemic drug delivery, surgical approaches. Regarding implant-related approaches, most experimental and numerical models do not generally impose conditions that represent mechanical instability at the implant interface, or recalcitrant healing. Many treatments will work well in forgiving settings, but fail in complex human settings with disease, bone loss, or previous surgery. Ethical considerations mandate that we justify and limit the number of animals tested, which restricts experimental permutations of treatments. Numerical models provide flexibility to evaluate multiple parameters and combinations, but generally need to employ simplifying assumptions. The objectives of this paper are to (a) to highlight the importance of mechanical, material, and surgical features to influence implant–bone healing, using a selection of results from two decades of coordinated experimental and numerical work and (b) discuss limitations of such models and the implications for research reproducibility. Focusing model conditions toward the clinical scenario to be studied, and limiting conclusions to the conditions of a particular model can increase clinical relevance and research reproducibility. PMID:26720312

  17. Temporal bone dissection simulator for training pediatric otolaryngology surgeons

    NASA Astrophysics Data System (ADS)

    Tabrizi, Pooneh R.; Sang, Hongqiang; Talari, Hadi F.; Preciado, Diego; Monfaredi, Reza; Reilly, Brian; Arikatla, Sreekanth; Enquobahrie, Andinet; Cleary, Kevin

    2017-03-01

    Cochlear implantation is the standard of care for infants born with severe hearing loss. Current guidelines approve the surgical placement of implants as early as 12 months of age. Implantation at a younger age poses a greater surgical challenge since the underdeveloped mastoid tip, along with thin calvarial bone, creates less room for surgical navigation and can result in increased surgical risk. We have been developing a temporal bone dissection simulator based on actual clinical cases for training otolaryngology fellows in this delicate procedure. The simulator system is based on pre-procedure CT (Computed Tomography) images from pediatric infant cases (<12 months old) at our hospital. The simulator includes: (1) simulation engine to provide the virtual reality of the temporal bone surgery environment, (2) a newly developed haptic interface for holding the surgical drill, (3) an Oculus Rift to provide a microscopic-like view of the temporal bone surgery, and (4) user interface to interact with the simulator through the Oculus Rift and the haptic device. To evaluate the system, we have collected 10 representative CT data sets and segmented the key structures: cochlea, round window, facial nerve, and ossicles. The simulator will present these key structures to the user and warn the user if needed by continuously calculating the distances between the tip of surgical drill and the key structures.

  18. Applications of patient-specific 3D printing in medicine.

    PubMed

    Heller, Martin; Bauer, Heide-Katharina; Goetze, Elisabeth; Gielisch, Matthias; Roth, Klaus E; Drees, Philipp; Maier, Gerrit S; Dorweiler, Bernhard; Ghazy, Ahmed; Neufurth, Meik; Müller, Werner E G; Schröder, Heinz C; Wang, Xiaohong; Vahl, Christian-Friedrich; Al-Nawas, Bilal

    Already three decades ago, the potential of medical 3D printing (3DP) or rapid prototyping for improved patient treatment began to be recognized. Since then, more and more medical indications in different surgical disciplines have been improved by using this new technique. Numerous examples have demonstrated the enormous benefit of 3DP in the medical care of patients by, for example, planning complex surgical interventions preoperatively, reducing implantation steps and anesthesia times, and helping with intraoperative orientation. At the beginning of every individual 3D model, patient-specific data on the basis of computed tomography (CT), magnetic resonance imaging (MRI), or ultrasound data is generated, which is then digitalized and processed using computer-aided design/computer-aided manufacturing (CAD/CAM) software. Finally, the resulting data sets are used to generate 3D-printed models or even implants. There are a variety of different application areas in the various medical fields, eg, drill or positioning templates, or surgical guides in maxillofacial surgery, or patient-specific implants in orthopedics. Furthermore, in vascular surgery it is possible to visualize pathologies such as aortic aneurysms so as to improve the planning of surgical treatment. Although rapid prototyping of individual models and implants is already applied very successfully in regenerative medicine, most of the materials used for 3DP are not yet suitable for implantation in the body. Therefore, it will be necessary in future to develop novel therapy approaches and design new materials in order to completely reconstruct natural tissue.

  19. A new surgical method for penile girth enhancement

    PubMed Central

    Li, Xiaoge; Tao, Ling; Cao, Chuan; Shi, Haishan; Li, Le; Chen, Liang; Li, Shirong

    2015-01-01

    Objective: We developed a new surgical model of penile girth enhancement in dog, with minimal damage, fewer complications, and high success rate, to enable the experimental investigation of penile implants. Methods: We obtained materials for penile girth enhancement by processing the pericardium and blood vessel wall collected from pigs. Incisions were made at the penile bulb for the implantation of the materials, and facilitate observation and data collection, based on the anatomical features of dog’s penis. We measured the girth of the flaccid penis before and after the operation, and erectile function at 1-month postoperation. In addition to evaluation of recovery from the incision and local pathological changes, ultrasonic examination was performed to monitor the long-term changes associated with implantation. Results: The mean girth of the flaccid penis significantly increased from 7.37±0.40 cm before the operation, to 8.70±0.56 cm postoperation. Dogs resumed normal mating at 1 month after the operation, without any significant change in the mating time. Ultrasonic examination clearly illustrated the implants, and helped in the measurement of the distance between the materials and the baculum. Conclusion: Chinese Rural dog is a promising animal model for penile girth enhancement surgery. The findings demonstrated that surgical implantation into penile bulb was associated with less damage, faster postoperative recovery, and higher success. For the first time, ultrasonic examination provided objective data on the surgical outcomes of penile girth enhancement. PMID:26379868

  20. Magnetic Resonance Imaging Distortion and Targeting Errors from Strong Rare Earth Metal Magnetic Dental Implant Requiring Revision.

    PubMed

    Seong-Cheol, Park; Chong Sik, Lee; Seok Min, Kim; Eu Jene, Choi; Do Hee, Lee; Jung Kyo, Lee

    2016-12-22

    Recently, the use of magnetic dental implants has been re-popularized with the introduction of strong rare earth metal, for example, neodymium, magnets. Unrecognized magnetic dental implants can cause critical magnetic resonance image distortions. We report a case involving surgical failure caused by a magnetic dental implant. A 62-year-old man underwent deep brain stimulation for medically insufficiently controlled Parkinson's disease. Stereotactic magnetic resonance imaging performed for the first deep brain stimulation showed that the overdenture was removed. However, a dental implant remained and contained a neodymium magnet, which was unrecognized at the time of imaging; the magnet caused localized non-linear distortions that were the largest around the dental magnets. In the magnetic field, the subthalamic area was distorted by a 4.6 mm right shift and counter clockwise rotation. However, distortions were visually subtle in the operation field and small for distant stereotactic markers, with approximately 1-2 mm distortions. The surgeon considered the distortion to be normal asymmetry or variation. Stereotactic marker distortion was calculated to be in the acceptable range in the surgical planning software. Targeting errors, approximately 5 mm on the right side and 2 mm on the left side, occurred postoperatively. Both leads were revised after the removal of dental magnets. Dental magnets may cause surgical failures and should be checked and removed before stereotactic surgery. Our findings should be considered when reviewing surgical precautions and making distortion-detection algorithm improvements.

  1. [Gluteoplasty with intramuscular silicone cohesive gel implants: a retrospective study of 50 cases].

    PubMed

    Horn, G

    2009-10-01

    For a few years, surgery of the gluteus has become more and more popular. In this retrospective study of 50 cases over a period of five years, the author presents his results, using a personal technique of gluteoplasty with intramuscular implants. After a review of the different current surgical techniques and of the different types of gluteus, the author describes his own surgical strategy.

  2. Combined Glaucoma Tube Shunt (Ahmed) and Fluocinolone Acetonide (Retisert™) Implantation Compared to Ahmed Alone in Uveitic Glaucoma.

    PubMed

    Zivney, Mark; Lin, Phoebe; Edmunds, Beth; Parikh, Mansi; Takusagawa, Hana; Tehrani, Shandiz

    2016-12-01

    Glaucoma is a known complication of uveitis, and may require glaucoma tube shunt implantation for intraocular pressure (IOP) control. The success of glaucoma tube shunt implantation in the setting of a local ocular steroid depot in uveitic glaucoma remains unknown. The purpose of this study was to determine whether patients who underwent combined glaucoma tube shunt (Ahmed) and fluocinolone acetonide (Retisert™, Bausch + Lomb, Bridgewater, NJ, USA) implantation have superior outcomes compared to patients with Ahmed implants only in the setting of uveitic glaucoma. All participants were studied retrospectively and underwent Ahmed implantation alone or with existing/concurrent Retisert implantation (combined group) at a single academic institution. The main outcome measures were IOP, visual acuity (VA), number of IOP-lowering medications, and adverse events at 6 months after Ahmed implantation. Secondary outcome measures included adverse events and surgical success at 6 months after Ahmed implantation. Mean IOP at 6 months after Ahmed implantation was 15.3 ± 4.8 and 15.1 ± 4.9 mm Hg in the Ahmed only group (n = 17) and the combined group (n = 17), respectively (p = 0.89). The mean number of IOP-lowering medications at 6 months after Ahmed implantation was 1.7 ± 1.0 and 1.8 ± 1.0 in the Ahmed only group and the combined group, respectively (p = 0.86). Mean VA at 6 months after Ahmed implantation was 0.35 ± 0.29 and 0.42 ± 0.33 log mean angle of resolution in the Ahmed only group and the combined group, respectively (p = 0.50). No significant differences in surgical success or adverse events were noted between the two groups. At 6 months, no significant differences in mean IOP, mean number of IOP-lowering medications, VA, surgical success, or adverse events were noted between Ahmed implantation alone or combined Ahmed and Retisert implantation in patients with uveitic glaucoma.

  3. Early experience of transaortic TAVI--the future of surgical TAVI?

    PubMed

    Clarke, Andrew; Wiemers, Paul; Poon, Karl K C; Aroney, Constantine N; Scalia, Gregory; Burstow, Darryl; Walters, Darren L; Tesar, Peter

    2013-04-01

    Trans-catheter aortic valve implantation (TAVI) is now a well recognised procedure for the high risk surgical patient with native or bioprosthetic aortic valve stenosis. Transfemoral and transapical implantation techniques are well described. With increasing referral of more marginal transapical patients, we describe our experience of a transaortic TAVI approach which we believe reduces the postoperative wound pain, respiratory complications, operative risk and hospital stay. Patients referred for surgical TAVI underwent trans-catheter aortic valve implantation via an upper sternotomy and direct cannulation of the ascending aorta. Thirteen patients with a mean age of 81 years underwent transaortic Edwards SAPIEN valve implantation. There was no in hospital mortality in our series. One patient required insertion of a permanent pacemaker for complete heart block. There were no aortic cannulation complications. The transaortic TAVI approach provides good exposure of the distal ascending aorta, a familiar cannulation site for cardiac surgeons. Our initial experience demonstrates the approach to be a safe technique with the potential for faster and less complicated recovery in patients undergoing surgical TAVI procedures. With further experience and greater acceptance, the transaortic approach may ultimately become the procedure of choice for patients unsuitable for a transfemoral approach. Crown Copyright © 2012. Published by Elsevier B.V. All rights reserved.

  4. Versatility of Capsular Flaps in the Salvage of Exposed Breast Implants

    PubMed Central

    Tenna, Stefania; Cagli, Barbara; Pallara, Tiziano; Campa, Stefano; Persichetti, Paolo

    2015-01-01

    Summary: Breast implant exposure due to poor tissue coverage or previous irradiation represents a surgical challenge both in the reconstructive and aesthetic plastic surgery practice. In case of implant extrusion or incipient exposure, the commonly suggested strategies, such as targeted antibiotic therapy, drainage and lavage of the cavity, fistulectomy, and primary closure, may be ineffective leading the surgeon to an unwanted implant removal or to adopt more invasive flap coverage procedures. Breast implant capsule, in its physiological clinical behavior, can be considered as a new reliable source of tissue, which can be used in a wide range of clinical situations. In our hands, capsular flaps proved to be a versatile solution not only to treat breast contour deformities or inframammary fold malpositions but also to salvage exposed breast implants. In this scenario, the use of more invasive surgical techniques can be avoided or simply saved and delayed for future recurrences.(Plast Reconstr Surg Glob Open 2015;3:e340; doi:10.1097/GOX.0000000000000307; Published online 30 March 2015.) PMID:26034647

  5. A simple way to plan implant positioning: the "S-technique".

    PubMed

    Piano, Sergio

    2011-01-01

    This study presents a technique for improving implant placements. As is widely known, a correct positioning is essential in restoration-driven implants, as well as in tilted implants in order to obtain satisfactory final functional and esthetic results. To this end, some authors have emphasized the importance of using a diagnostic and/or surgical guide to plan the exact implant position. In practice, one of the clinical problems faced is how to check the accuracy of the template prior to initiating the surgical phase. A simple method called the "S-Technique" is proposed in order to evaluate and to change, if necessary, the projected position of the implants by way of metal rods as radiopaque markers. This device is easy to produce and is cost-saving to the clinician and, therefore, to the patient. Furthermore, in specific patients, this method could also decrease the need for computerized tomography scans and/or radiographs, thus reducing health risks for the patient.

  6. Repair of a Giant Omphalocele in an Infant With a Pericardial Implant Crosslinked With Oligourethane.

    PubMed

    Vargas-Mancilla, Juan; Torrero-Serrato, María A; Palacios-Rodríguez, Aarón J; Rodríguez-de León, Gloria B; Montes-Rodríguez, Metzeri I; Mendoza-Novelo, Birzabith

    2018-04-16

    The giant omphalocele (GO) represents a challenge for the pediatric surgeon in its management and wall abdominoplasty. Here, we report the outcome of a case in which a GO in a newborn patient was repaired with an implant derived from decellularized bovine pericardium crosslinked with oligourethane. The implantation time was extended for 6 months. This was then followed up by the retrieval of the implant and the subsequent reconstruction in a second surgical time by the closure of the abdominal wall fascia. A short hospital stay, early integration into the patient's family environment, as well as early onset of the oral route without special care of the implant or reconstructed wall nor food restrictions were observed. The reduced presence of the complications described in the literature after application of surgical meshes suggests that this implant can be an effective and safe alternative method in the treatment of abdominal wall defects such as GO. © 2018 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  7. Surgical treatment of osteoporotic fractures: An update on the principles of management.

    PubMed

    Yaacobi, Eyal; Sanchez, Daniela; Maniar, Hemil; Horwitz, Daniel S

    2017-12-01

    The treatment of osteoporotic fractures continues to challenge orthopedic surgeon. The fragility of the underlying bone in conjunction with the need for specific implants led to the development of explicit surgical techniques in order to minimize implant failure related complications, morbidity and mortality. From the patient's perspective, the existence of frailty, dementia and other medical related co-morbidities induce a complex situation necessitating high vigilance during the perioperative and post-operative period. This update reviews current principles and techniques essential to successful surgical treatment of these injuries. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. Cementless Hydroxyapatite Coated Hip Prostheses

    PubMed Central

    Herrera, Antonio; Mateo, Jesús; Gil-Albarova, Jorge; Lobo-Escolar, Antonio; Ibarz, Elena; Gabarre, Sergio; Más, Yolanda

    2015-01-01

    More than twenty years ago, hydroxyapatite (HA), calcium phosphate ceramics, was introduced as a coating for cementless hip prostheses. The choice of this ceramic is due to its composition being similar to organic apatite bone crystals. This ceramic is biocompatible, bioactive, and osteoconductive. These qualities facilitate the primary stability and osseointegration of implants. Our surgical experience includes the implantation of more than 4,000 cementless hydroxyapatite coated hip prostheses since 1990. The models implanted are coated with HA in the acetabulum and in the metaphyseal area of the stem. The results corresponding to survival and stability of implants were very satisfactory in the long-term. From our experience, HA-coated hip implants are a reliable alternative which can achieve long term survival, provided that certain requirements are met: good design selection, sound choice of bearing surfaces based on patient life expectancy, meticulous surgical technique, and indications based on adequate bone quality. PMID:25802848

  9. Virtual Preoperative Planning and Intraoperative Navigation in Facial Prosthetic Reconstruction: A Technical Note.

    PubMed

    Verma, Suzanne; Gonzalez, Marianela; Schow, Sterling R; Triplett, R Gilbert

    This technical protocol outlines the use of computer-assisted image-guided technology for the preoperative planning and intraoperative procedures involved in implant-retained facial prosthetic treatment. A contributing factor for a successful prosthetic restoration is accurate preoperative planning to identify prosthetically driven implant locations that maximize bone contact and enhance cosmetic outcomes. Navigational systems virtually transfer precise digital planning into the operative field for placing implants to support prosthetic restorations. In this protocol, there is no need to construct a physical, and sometimes inaccurate, surgical guide. The report addresses treatment workflow, radiologic data specifications, and special considerations in data acquisition, virtual preoperative planning, and intraoperative navigation for the prosthetic reconstruction of unilateral, bilateral, and midface defects. Utilization of this protocol for the planning and surgical placement of craniofacial bone-anchored implants allows positioning of implants to be prosthetically driven, accurate, precise, and efficient, and leads to a more predictable treatment outcome.

  10. Computer-aided insertion of endosteal implants in the zygoma: a pilot study

    NASA Astrophysics Data System (ADS)

    Birkfellner, Wolfgang; Watzinger, Franz; Wanschitz, Felix; Ziya, F.; Kremser, J.; Potyka, A.; Mayr, R.; Huber, Klaus; Kainberger, F.; Ewers, Rolf; Bergmann, Helmar

    2000-04-01

    Endosteal implants facilitate obturator prosthesis fixation in tumor patients after maxillectomy. Previous clinical studies shown however, that survival of implants placed into available bone after maxillectomy is generally poor. Implants positioned optimally in residual zygomatic bone provide superior stability form a biomechanical point of view as well as improved survival. In a pilot study, we have assessed the precision of VISIT, a surgical navigation system developed for research purposes at our institution. VISIT is based on the AVW-library and a number of in-house developed algorithms for communication with an optical tracker and patient-to-CT-registration. The final platform independent application was assembled within 6 man-months using ANSI-C and Tcl/Tk. Five cadaver specimens underwent hemimaxillectomy. The cadaver head was matched to a preoperative high resolution CT by using implanted surgical microscrews as fiducial markers. The position of a surgical drill relative to the cadaver head was determined with an optical tracking system. Implants were placed into the zygomatic arch where maximum bone volume was available. The results were assessed using test for allocation accuracy and postoperative CT-scans of the cadaver specimens. The average allocation accuracy of landmarks on the bony skull was 0.6 +/- 0.3 mm determined with a 5 degree-of-freedom pointer probe. The allocation accuracy of the tip of the implant burr was 1.7 +/- 0.4 mm. The accuracy of the implant position compared to the planned position was 1.5 +/- 1.1 mm. 8 out of 10 implants were inserted with maximum contact to surrounding bone, two implants were located unfavorably. However, reliable placement of implants in this region is difficult to achieve. The techqni3u described in this paper may be very helpful in the management of patients after maxillary resection without sufficient retention for obturator prostheses.

  11. Comparison of surgical time and IOP spikes with two ophthalmic viscosurgical devices following Visian STAAR (ICL, V4c model) insertion in the immediate postoperative period.

    PubMed

    Ganesh, Sri; Brar, Sheetal

    2016-01-01

    To compare the effect of two ocular viscosurgical devices (OVDs) on intraocular pressure (IOP) and surgical time in immediate postoperative period after bilateral implantable collamer lens (using the V4c model) implantation. A total of 20 eligible patients were randomized to receive 2% hydroxypropylmethylcellulose (HPMC) in one eye and 1% hyaluronic acid in fellow eye. Time taken for complete removal of OVD and total surgical time were recorded. At the end of surgery, IOP was adjusted between 15 and 20 mmHg in both the eyes. Mean time for complete OVD evacuation and total surgical time were significantly higher in the HPMC group (P=0.00). Four eyes in the HPMC group had IOP spike, requiring treatment. IOP values with noncontact tonometry at 1, 2, 4, 24, and 48 hours were not statistically significant (P>0.05) for both the groups. The study concluded that 1% hyaluronic acid significantly reduces total surgical time, and incidence of acute spikes may be lower compared to 2% HPMC when used for implantable collamer lens (V4c model).

  12. Comparison of surgical time and IOP spikes with two ophthalmic viscosurgical devices following Visian STAAR (ICL, V4c model) insertion in the immediate postoperative period

    PubMed Central

    Ganesh, Sri; Brar, Sheetal

    2016-01-01

    Purpose To compare the effect of two ocular viscosurgical devices (OVDs) on intraocular pressure (IOP) and surgical time in immediate postoperative period after bilateral implantable collamer lens (using the V4c model) implantation. Methods A total of 20 eligible patients were randomized to receive 2% hydroxypropylmethylcellulose (HPMC) in one eye and 1% hyaluronic acid in fellow eye. Time taken for complete removal of OVD and total surgical time were recorded. At the end of surgery, IOP was adjusted between 15 and 20 mmHg in both the eyes. Results Mean time for complete OVD evacuation and total surgical time were significantly higher in the HPMC group (P=0.00). Four eyes in the HPMC group had IOP spike, requiring treatment. IOP values with noncontact tonometry at 1, 2, 4, 24, and 48 hours were not statistically significant (P>0.05) for both the groups. Conclusion The study concluded that 1% hyaluronic acid significantly reduces total surgical time, and incidence of acute spikes may be lower compared to 2% HPMC when used for implantable collamer lens (V4c model). PMID:26869754

  13. [Impact of anchorage implant design factors on its primary stability].

    PubMed

    Zhang, J N; Lu, H P; Zhong, C

    2017-08-09

    During the past decade, the anchorage implants have been widely used in the orthodontic treatment. Many scholars have studied the influence of different factors on anchorage implant's primary stability, including anchorage implant's material properties, structural design, surgical procedure, bone condition, loading force's magnitude and direction. This article is to review the influence of anchorage implant's shape, dimension, neck design and thread design on its primary stability.

  14. Surgical Tooth Implants, Combat and Field.

    DTIC Science & Technology

    1985-11-15

    project in the development of dental implantology must not be overlooked. The early stages of this project clearly defined that rigid fixation of an...a long-term implant study of a serrated ceramic dental implant designed for fresh extraction sites. The baboon study was successfully completed last...materials. A series of graded dental implants have been produce’ to provide an interference fit in any fresh extraction site. The long-term implant

  15. Alternative Distraction Osteogenesis Technique After Implant Placement for Alveolar Ridge Augmentation of the Maxilla.

    PubMed

    Nogueira, Renato Luiz Maia; Osterne, Rafael Lima Verde; Abreu, Ricardo Teixeira; Araújo, Phelype Maia

    2017-07-01

    An alternative technique to reconstruct atrophic alveolar vertical bone after implant placement is presented. The technique consists of distraction osteogenesis or direct surgical repositioning of an implant-and-bone block segment after segmental osteotomies that can be used in esthetic or unesthetic cases. Initially, casts indicating the implant position are obtained and the future ideal prosthetic position is determined to guide the model surgery. After the model surgery, a new provisional prosthesis is fabricated, and an occlusal splint, which is used as a surgical guide and a device for distraction osteogenesis, is custom fabricated. Then, the surgery is performed. For mobilization of the implant-and-bone block segment, 2 vertical osteotomies are performed and then joined by a horizontal osteotomy. The implant-and-bone block segment is moved to the planned position. If a small movement is planned, then the implant-and-bone segment is stabilized; for larger movements, the implant-and-bone segment can be gradually moved to the final position by distraction osteogenesis. This technique has good predictability of the final position of the implant-and-bone segment and relatively fast esthetic rehabilitation. It can be considered for dental implants in regions of vertical bone atrophy. Copyright © 2017 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  16. Mechanical behaviour of synthetic surgical meshes: finite element simulation of the herniated abdominal wall.

    PubMed

    Hernández-Gascón, B; Peña, E; Melero, H; Pascual, G; Doblaré, M; Ginebra, M P; Bellón, J M; Calvo, B

    2011-11-01

    The material properties of meshes used in hernia surgery contribute to the overall mechanical behaviour of the repaired abdominal wall. The mechanical response of a surgical mesh has to be defined since the haphazard orientation of an anisotropic mesh can lead to inconsistent surgical outcomes. This study was designed to characterize the mechanical behaviour of three surgical meshes (Surgipro®, Optilene® and Infinit®) and to describe a mechanical constitutive law that accurately reproduces the experimental results. Finally, through finite element simulation, the behaviour of the abdominal wall was modelled before and after surgical mesh implant. Uniaxial loading of mesh samples in two perpendicular directions revealed the isotropic response of Surgipro® and the anisotropic behaviour of Optilene® and Infinit®. A phenomenological constitutive law was used to reproduce the measured experimental curves. To analyze the mechanical effect of the meshes once implanted in the abdomen, finite element simulation of the healthy and partially herniated repaired rabbit abdominal wall served to reproduce wall behaviour before and after mesh implant. In all cases, maximal displacements were lower and maximal principal stresses higher in the implanted abdomen than the intact wall model. Despite the fact that no mesh showed a behaviour that perfectly matched that of abdominal muscle, the Infinit® mesh was able to best comply with the biomechanics of the abdominal wall. Copyright © 2011 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  17. Bilateral sacroiliac luxation fixation using a single transiliosacral pin: surgical technique and clinical outcomes in eight cats.

    PubMed

    Parslow, A; Simpson, D J

    2017-06-01

    A very limited safe anatomical window for transiliosacral implant placement exists in cats (<0·5 cm 2 ). Lag screw fixation requires multiple bilateral implants thus increasing the risk of iatrogenic trauma and implant interference. We describe a safe and effective method for bilateral sacroiliac fixation in cats using a single implant to minimise inadvertent iatrogenic damage to local structures and restore pelvic canal diameter. Eight cats underwent surgical fixation for traumatic bilateral sacroiliac luxation using a single smooth intramedullary pin. The pin spanned both ilial wings and sacrum. Implants were applied using a Universal C-guide. Pre- and postsurgery pelvic canal diameter ratios were calculated. Short-term follow-up was performed at 10 to 14 days postoperatively. Long-term follow-up was performed using the Feline Musculoskeletal Pain Index Questionnaire. Long-term radiographic assessment was available in two cases. The technique achieved safe and accurate implant position with precise sacroiliac joint reduction. Pelvic canal diameter ratios were restored to normal in all cases. Rapid return to normal hind leg function and excellent long-term clinical outcomes were achieved. This technique offers a simple, safe, repeatable and affordable technique for treating bilateral sacroiliac luxations in the cat without the aid of fluoroscopy. The procedure can be performed using surgical tools and inventory readily available in general small animal practices. © 2017 British Small Animal Veterinary Association.

  18. Noncardiac Surgical Procedures After Left Ventricular Assist Device Implantation.

    PubMed

    Taghavi, Sharven; Jayarajan, Senthil N; Ambur, Vishnu; Mangi, Abeel A; Chan, Elaine; Dauer, Elizabeth; Sjoholm, Lars O; Pathak, Abhijit; Santora, Thomas A; Goldberg, Amy J; Rappold, Joseph F

    2016-01-01

    As left ventricular assist devices (LVADs) are increasingly used for patients with end-stage heart failure, the need for noncardiac surgical procedures (NCSs) in these patients will continue to rise. We examined the various types of NCS required and its outcomes in LVAD patients requiring NCS. The National Inpatient Sample Database was examined for all patients implanted with an LVAD from 2007 to 2010. Patients requiring NCS after LVAD implantation were compared to all other patients receiving an LVAD. There were 1,397 patients undergoing LVAD implantation. Of these, 298 (21.3%) required 459 NCS after LVAD implantation. There were 153 (33.3%) general surgery procedures, with abdominal/bowel procedures (n = 76, 16.6%) being most common. Thoracic (n = 141, 30.7%) and vascular (n = 140, 30.5%) procedures were also common. Patients requiring NCS developed more wound infections (9.1 vs. 4.6%, p = 0.004), greater bleeding complications (44.0 vs. 24.8%, p < 0.001) and were more likely to develop any complication (87.2 vs. 82.0%, p = 0.001). On multivariate analysis, the requirement of NCSs (odds ratio: 1.45, 95% confidence interval: 0.95-2.20, p = 0.08) was not associated with mortality. Noncardiac surgical procedures are commonly required after LVAD implantation, and the incidence of complications after NCS is high. This suggests that patients undergoing even low-risk NCS should be cared at centers with treating surgeons and LVAD specialists.

  19. Fixation of Hydroxyapatite-Coated Revision Implants Is Improved by the Surgical Technique of Cracking the Sclerotic Bone Rim

    PubMed Central

    Elmengaard, Brian; Bechtold, Joan E.; Chen, Xinqian; Søballe, Kjeld

    2013-01-01

    Revision joint replacement has poorer outcomes that have been associated with poorer mechanical fixation. We investigate a new bone-sparing surgical technique that locally cracks the sclerotic bone rim formed during aseptic loosening. We inserted 16 hydroxyapatite-coated implants bilaterally in the distal femur of eight dogs, using a controlled weight-bearing experimental model that replicates important features of a typical revision setting. At 8 weeks, a control revision procedure and a crack revision procedure were performed on contralateral implants. The crack procedure used a splined tool to perform a systematic local perforation of the sclerotic bone rim of the revision cavity. After 4 weeks, the hydroxyapatite-coated implants were evaluated for mechanical fixation by a push-out test and for tissue distribution by histomorphometry. The cracking revision procedure resulted in significantly improved mechanical fixation, significantly more bone ongrowth and bone volume in the gap, and reduced fibrous tissue compared to the control revision procedure. The study demonstrates that the sclerotic bone rim prevents bone ingrowth and promotes fixation by fibrous tissue. The effect of the cracking technique may be due to improved access to the vascular compartment of the bone. The cracking technique is a simple surgical method that potentially can improve the fixation of revision implants in sclerotic regions important for obtaining the fixation critical for overall implant stability. PMID:19148940

  20. Penile prosthesis implant: scientific advances and technological innovations over the last four decades.

    PubMed

    Chung, Eric

    2017-02-01

    Despite introduction of oral phosphodiesterase type 5 inhibitors and intracavernosal vasoactive agents, penile prosthesis implant remains a relevant and desired option with sales of penile prostheses continue to stay high, as many men became refractory to medical therapy and/or seeking a more effective and permanent therapy. There are two types of penile prosthesis implants: inflatable and non-inflatable types, and the inflatable penile implants can be subdivided into single-, two- and three-piece devices. Non-inflatable penile prosthesis (non-IPP) may be referred to as semi-rigid rod or malleable prosthesis. IPP is considered a superior option to malleable prosthesis as it produces penile rigidity and flaccidity that closely replicates a normal penile erectile function. Since the introduction of IPP by Scott in 1973, surgical landscape for penile prosthesis implantation has changed dramatically. Advances in prosthesis design, device technologies and surgical techniques have made penile prosthesis implant a more natural, durable and reliable device. The following article reviews the scientific advances and technological innovation in modern penile prosthesis implants over the last four decades.

  1. Penile prosthesis implant: scientific advances and technological innovations over the last four decades

    PubMed Central

    2017-01-01

    Despite introduction of oral phosphodiesterase type 5 inhibitors and intracavernosal vasoactive agents, penile prosthesis implant remains a relevant and desired option with sales of penile prostheses continue to stay high, as many men became refractory to medical therapy and/or seeking a more effective and permanent therapy. There are two types of penile prosthesis implants: inflatable and non-inflatable types, and the inflatable penile implants can be subdivided into single-, two- and three-piece devices. Non-inflatable penile prosthesis (non-IPP) may be referred to as semi-rigid rod or malleable prosthesis. IPP is considered a superior option to malleable prosthesis as it produces penile rigidity and flaccidity that closely replicates a normal penile erectile function. Since the introduction of IPP by Scott in 1973, surgical landscape for penile prosthesis implantation has changed dramatically. Advances in prosthesis design, device technologies and surgical techniques have made penile prosthesis implant a more natural, durable and reliable device. The following article reviews the scientific advances and technological innovation in modern penile prosthesis implants over the last four decades. PMID:28217449

  2. Treatment of an Erratic Extraction Socket for Implant Therapy in a Patient with Chronic Periodontitis.

    PubMed

    Hamada, Yusuke; Prabhu, Srividya; John, Vanchit

    2016-01-01

    As implant therapy becomes more commonplace in daily practice, preservation and preparation of edentulous sites are key. Many times, however, implant therapy may not be considered at the time of tooth extraction and additional measures are not taken to conserve the edentulous site. While the healing process in extraction sockets has been well investigated and bone fill can be expected, there are cases where even when clinicians perform thorough debridement of the sockets, connective tissue infiltration into the socket can occur. This phenomenon, known as "erratic healing," may be associated with factors that lead to peri-implant disease and should be appropriately managed and treated prior to surgical implant placement. This case report describes the successful management of an erratic healing extraction socket in a 62-year-old Caucasian male patient with chronic periodontitis and the outcomes of an evidence-based treatment protocol performed prior to implant therapy. Careful preoperative analysis and cone beam computed tomography imaging can help detect signs of impaired healing in future implant sites and prevent surgical complications.

  3. Staged Hard and Soft Tissue Reconstruction Followed by Implant Supported Restoration in the Aesthetic Zone: A Case Report.

    PubMed

    Parthasarathy, Harinath; Ramachandran, Lakshmi; Tadepalli, Anupama; Ponnaiyan, Deepa

    2017-04-01

    Alveolar ridge deficiency is a common clinical consequence following tooth loss due to chronic periodontitis complicating ideal implant placement. Advanced hard and soft tissue augmentation procedures have been developed in the recent past with predictable clinical outcomes. A male patient presented with a Grade III mobile upper right central incisor associated with advanced bone loss and soft tissue deficit. Following extraction of tooth #11, socket augmentation was done using an autogenous cortico-cancellous block graft and subsequent soft tissue augmentation was done with palatal connective tissue graft. At the end of six months, a tapered self tapping implant fixture was placed with adequate primary stability and after eight weeks, second stage implant surgery was done with the Misch technique in order to recreate papillae and the implant was prosthetically restored. The alveolar ridge was adequately recontoured following the staged surgical protocol. The implant was well integrated at the end of 15 months. Execution of sequential surgical procedures in a highly deficient edentulous site made it possible to achieve of optimal pink and white aesthetics with stable implant supported fixed prosthesis.

  4. Reducing infection risk in implant-based breast-reconstruction surgery: challenges and solutions

    PubMed Central

    Ooi, Adrian SH; Song, David H

    2016-01-01

    Implant-based procedures are the most commonly performed method for postmastectomy breast reconstruction. While donor-site morbidity is low, these procedures are associated with a higher risk of reconstructive loss. Many of these are related to infection of the implant, which can lead to prolonged antibiotic treatment, undesired additional surgical procedures, and unsatisfactory results. This review combines a summary of the recent literature regarding implant-related breast-reconstruction infections and combines this with a practical approach to the patient and surgery aimed at reducing this risk. Prevention of infection begins with appropriate reconstructive choice based on an assessment and optimization of risk factors. These include patient and disease characteristics, such as smoking, obesity, large breast size, and immediate reconstructive procedures, as well as adjuvant therapy, such as radiotherapy and chemotherapy. For implant-based breast reconstruction, preoperative planning and organization is key to reducing infection. A logical and consistent intraoperative and postoperative surgical protocol, including appropriate antibiotic choice, mastectomy-pocket creation, implant handling, and considered acellular dermal matrix use contribute toward the reduction of breast-implant infections. PMID:27621667

  5. Treatment of an Erratic Extraction Socket for Implant Therapy in a Patient with Chronic Periodontitis

    PubMed Central

    Prabhu, Srividya

    2016-01-01

    As implant therapy becomes more commonplace in daily practice, preservation and preparation of edentulous sites are key. Many times, however, implant therapy may not be considered at the time of tooth extraction and additional measures are not taken to conserve the edentulous site. While the healing process in extraction sockets has been well investigated and bone fill can be expected, there are cases where even when clinicians perform thorough debridement of the sockets, connective tissue infiltration into the socket can occur. This phenomenon, known as “erratic healing,” may be associated with factors that lead to peri-implant disease and should be appropriately managed and treated prior to surgical implant placement. This case report describes the successful management of an erratic healing extraction socket in a 62-year-old Caucasian male patient with chronic periodontitis and the outcomes of an evidence-based treatment protocol performed prior to implant therapy. Careful preoperative analysis and cone beam computed tomography imaging can help detect signs of impaired healing in future implant sites and prevent surgical complications. PMID:27807485

  6. A miniaturized glucose biosensor for in vitro and in vivo studies.

    PubMed

    Yang, Yang-Li; Huang, Jian-Feng; Tseng, Ta-Feng; Lin, Chia-Ching; Lou, Shyh-Liang

    2008-01-01

    A miniaturized wireless glucose biosensor has been developed to perform in vitro and in vivo studies. It consists of an external control subsystem and an implant sensing subsystem. The implant subsystem consists of a micro-processor, which coordinates circuitries of radio frequency, power regulator, command demodulator, glucose sensing trigger and signal read-out. Except for a set of sensing electrodes, the micro-processor, the circuitries and a receiving coil were hermetically sealed with polydimethylsiloxane. The electrode set is a substrate of silicon oxide coated with platinum, which includes a working electrode and a reference electrode. Glucose oxidase was immobilized on the surface of the working electrode. The implant subsystem bi-directionally communicates with the external subsystem via radio frequency technologies. The external subsystem wirelessly supplies electricity to power the implant, issues commands to the implant to perform tasks, receives the glucose responses detected by the electrode, and relays the response signals to a computer through a RS-232 connection. Studies of in vitro and in vivo were performed to evaluate the biosensor. The linear response of the biosensor is up to 15 mM of glucose in vitro. The results of in vivo study show significant glucose variations measured from the interstitial tissue fluid of a diabetes rat in fasting and non-fasting periods.

  7. 21 CFR 878.4750 - Implantable staple.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Implantable staple. 878.4750 Section 878.4750 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4750 Implantable staple. (a...

  8. 21 CFR 878.4750 - Implantable staple.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Implantable staple. 878.4750 Section 878.4750 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4750 Implantable staple. (a...

  9. 21 CFR 878.4750 - Implantable staple.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Implantable staple. 878.4750 Section 878.4750 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4750 Implantable staple. (a...

  10. 21 CFR 878.4300 - Implantable clip.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Implantable clip. 878.4300 Section 878.4300 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4300 Implantable clip. (a...

  11. 21 CFR 878.4300 - Implantable clip.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Implantable clip. 878.4300 Section 878.4300 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4300 Implantable clip. (a...

  12. 21 CFR 878.4300 - Implantable clip.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Implantable clip. 878.4300 Section 878.4300 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4300 Implantable clip. (a...

  13. 21 CFR 878.4300 - Implantable clip.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Implantable clip. 878.4300 Section 878.4300 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4300 Implantable clip. (a...

  14. 21 CFR 878.4300 - Implantable clip.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Implantable clip. 878.4300 Section 878.4300 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4300 Implantable clip. (a...

  15. 21 CFR 878.4750 - Implantable staple.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Implantable staple. 878.4750 Section 878.4750 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4750 Implantable staple. (a...

  16. 21 CFR 878.4750 - Implantable staple.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Implantable staple. 878.4750 Section 878.4750 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4750 Implantable staple. (a...

  17. Treatment of peri-implant diseases: a review of the literature and protocol proposal.

    PubMed

    Armas, Joshé; Culshaw, Shauna; Savarrio, Lee

    2013-01-01

    Over 100,000 implants were placed in the UK in 2010. As the numbers of patients with implant-retained prostheses increases, operators are encountering an increasing number of biological implant complications, most commonly peri-implant mucositis and peri-implantitis. The effective management of these complications is crucial to maintain patients' oral health. In particular, in contrast to common periodontal infections, some peri-implant infections may benefit from surgical intervention as a first line approach. This article reviews the literature on the treatment options for peri-implant mucositis and peri-implantitis and proposes a protocol for their treatment.

  18. Hand Held Device for Wireless Powering and Interrogation of Biomems Sensors and Actuators

    NASA Technical Reports Server (NTRS)

    Simons, Rainee N (Inventor); Miranda, Felix Antonio (Inventor)

    2007-01-01

    A compact, hand-held device for wireless powering, interrogation and data retrieval from at least one implanted sensor. The hand-held device includes an antenna for powering an implanted sensor and for receiving data from the implanted sensor to the hand-held device for at least one of storage, display or analysis. The hand-held device establishes electromagnetic coupling with a low radiating radio frequency power inductor in the implanted sensor at a predefined separation and the antenna geometry allows for the antenna to power, interrogate and retrieve data from the implanted sensor without strapping the hand-held device to a human body housing the implanted sensor The hand-held device optionally allows for activation of the implanted sensor only during interrogation and data retrieval.

  19. A novel dental implant guided surgery based on integration of surgical template and augmented reality.

    PubMed

    Lin, Yen-Kun; Yau, Hong-Tzong; Wang, I-Chung; Zheng, Cheng; Chung, Kwok-Hung

    2015-06-01

    Stereoscopic visualization concept combined with head-mounted displays may increase the accuracy of computer-aided implant surgery. The aim of this study was to develop an augmented reality-based dental implant placement system and evaluate the accuracy of the virtually planned versus the actual prepared implant site created in vitro. Four fully edentulous mandibular and four partially edentulous maxillary duplicated casts were used. Six implants were planned in the mandibular and four in the maxillary casts. A total of 40 osteotomy sites were prepared in the casts using stereolithographic template integrated with augmented reality-based surgical simulation. During the surgery, the dentist could be guided accurately through a head-mounted display by superimposing the virtual auxiliary line and the drill stop. The deviation between planned and prepared positions of the implants was measured via postoperative computer tomography generated scan images. Mean and standard deviation of the discrepancy between planned and prepared sites at the entry point, apex, angle, depth, and lateral locations were 0.50 ± 0.33 mm, 0.96 ± 0.36 mm, 2.70 ± 1.55°, 0.33 ± 0.27 mm, and 0.86 ± 0.34 mm, respectively, for the fully edentulous mandible, and 0.46 ± 0.20 mm, 1.23 ± 0.42 mm, 3.33 ± 1.42°, 0.48 ± 0.37 mm, and 1.1 ± 0.39 mm, respectively, for the partially edentulous maxilla. There was a statistically significant difference in the apical deviation between maxilla and mandible in this surgical simulation (p < .05). Deviation of implant placement from planned position was significantly reduced by integrating surgical template and augmented reality technology. © 2013 Wiley Periodicals, Inc.

  20. Two-year clinical outcomes following non-surgical mechanical therapy of peri-implantitis with adjunctive diode laser application.

    PubMed

    Mettraux, Gérald R; Sculean, Anton; Bürgin, Walter B; Salvi, Giovanni E

    2016-07-01

    Non-surgical mechanical therapy of peri-implantitis (PI) with/without adjunctive measures yields limited clinical improvements. To evaluate the clinical outcomes following non-surgical mechanical therapy of PI with adjunctive application of a diode laser after an observation period ≥2 years. At baseline (BL), 15 patients with 23 implants with a sandblasted and acid-etched (SLA) surface diagnosed with PI were enrolled and treated. PI was defined as presence of probing pocket depths (PPD) ≥5 mm with bleeding on probing (BoP) and/or suppuration and ≥2 threads with bone loss after delivery of the restoration. Implant sites were treated with carbon fiber and metal curettes followed by repeated application of a diode laser 3x for 30 s (settings: 810 nm, 2.5 W, 50 Hz, 10 ms). This procedure was performed at Day 0 (i.e., baseline), 7 and 14. Adjunctive antiseptics or adjunctive systemic antibiotics were not prescribed. All implants were in function after 2 years. The deepest PPD decreased from 7.5 ± 2.6 mm to 3.6 ± 0.7 mm at buccal (P < 0.0001) and from 7.7 ± 2.1 mm to 3.8 ± 0.9 mm at oral sites (P < 0.0001), respectively. The % of implants with ≥1 site with BoP decreased from 100% at BL to 43% after 2 years (P = 0.0002). The % of implants with suppuration decreased from 87% at BL to 0% after 2 years (P < 0.0001). Non-surgical mechanical therapy of PI with adjunctive repeated application of a diode laser yielded significant clinical improvements after an observation period of at least 2 years. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  1. Short-term survival and effects of transmitter implantation into western grebes using a modified surgical procedure

    USGS Publications Warehouse

    Gaydos, Joseph K.; Massey, J. Gregory; Mulcahy, Daniel M.; Gaskins, Lori A.; Nysewander, David; Evenson, Joseph; Siegel, Paul B.; Ziccardi, Michael H.

    2011-01-01

    Two pilot trials and one study in a closely related grebe species suggest that Western grebes (Aechmophorus occidentalis) will not tolerate intracoelomic transmitter implantation with percutaneous antennae and often die within days of surgery. Wild Western grebes (n = 21) were captured to evaluate a modified surgical technique. Seven birds were surgically implanted with intracoelomic transmitters with percutaneous antennae by using the modified technique (transmitter group), 7 received the same surgery without transmitter implantation (celiotomy group), and 7 served as controls (only undergoing anesthesia). Modifications included laterally offsetting the body wall incision from the skin incision, application of absorbable cyanoacrylate tissue glue to the subcutaneous space between the body wall and skin incisions, application of a waterproof sealant to the skin incision after suture closure, and application of a piece of porcine small intestine submucosa to the antenna egress. Survival did not differ among the 3 groups with 7 of 7 control, 6 of 7 celiotomy, and 6 of 7 transmitter birds surviving the 9-day study. Experimental birds were euthanized at the end of the study, and postmortem findings indicated normal healing. Significant differences in plasma chemistry or immune function were not detected among the 3 groups, and only minor differences were detected in red blood cell indices and plasma proteins. After surgery, the birds in the transmitter group spent more time preening tail feathers than those in the control and celiotomy groups. These results demonstrate that, in a captive situation, celiotomy and intracoelomic transmitter implantation caused minimal detectable homeostatic disturbance in this species and that Western grebes can survive implantation of intracoelomic transmitters with percutaneous antennae. It remains to be determined what potential this modified surgical procedure has to improve postoperative survival of Western grebes that are intracelomically implanted with transmitters with percutaneous antennae and released into the wild.

  2. Is mammary reconstruction with the anatomical Becker expander a simple procedure? Complications and hidden problems leading to secondary surgical procedures: a follow-up study.

    PubMed

    Farace, Francesco; Faenza, Mario; Bulla, Antonio; Rubino, Corrado; Campus, Gian Vittorio

    2013-06-01

    Debate over the role of Becker expander implants (BEIs) in breast reconstruction is still ongoing. There are no clear indications for BEI use. The main indications for BEI use are one-stage breast reconstruction procedure and congenital breast deformities correction, due to the postoperative ability to vary BEI volume. Recent studies showed that BEIs were removed 5 years after mammary reconstruction in 68% of operated patients. This entails a further surgical procedure. BEIs should not, therefore, be regarded as one-stage prostheses. We performed a case-series study of breast reconstructions with anatomically shaped Becker-35™ implants, in order to highlight complications and to flag unseen problems, which might entail a second surgical procedure. A total of 229 patients, reconstructed from 2005 to 2010, were enrolled in this study. Data relating to implant type, volume, mean operative time and complications were recorded. All the patients underwent the same surgical procedure. The minimum follow-up period was 18 months. During a 5-year follow-up, 99 patients required secondary surgery to correct their complications or sequelae; 46 of them underwent BEI removal within 2 years of implantation, 56 within 3 years, 65 within 4 years and 74 within 5 years. Our findings show that two different sorts of complications can arise with these devices, leading to premature implant removal, one common to any breast implant and one peculiar to BEIs. The Becker implant is a permanent expander. Surgeons must, therefore, be aware that, once positioned, the Becker expander cannot be adjusted at a later date, as in two-stage expander/prosthesis reconstructions for instance. Surgeons must have a clear understanding of possible BEI complications in order to be able to discuss these with their patients. Therefore, only surgeons experienced in breast reconstruction should use BEIs. Copyright © 2013 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  3. Soft-tissue grafting for peri-implantitis-a treatment option in case of unsuitable skeletal basic morphology of the alveolar bone and lack of keratinized mucosa: a retrospective clinical cohort study.

    PubMed

    Stiller, Michael; Mengel, Rainer; Becher, Sebastian; Brinkmann, Bernhard; Peleska, Barbara; Kluk, Esther

    2015-12-01

    This retrospective study evaluated soft-tissue grafting as a surgical treatment option for peri-implantitis in case of unsuitable basic skeletal morphology of the alveolar bone and lack of keratinized mucosa. Twenty-eight patients (21 females, 7 males, at a mean age 59.4 years) were included with a total of 54 implants. All implants showed peri-implantitis and attached keratinized buccal mucosa of ≤2 mm. A surgical procedure of soft-tissue grafting (STG) was made by inserting an inlay and inlay-onlay transplant. Clinical investigations were made prior to the STG (baseline) and after 9-180 months (Ø 43 months) including the following parameters: soft-tissue biotype, skeletal basic morphology of the alveolar bone, width of the peri-implant keratinized mucosa (KM), mobility of the KM, pocket probing depth (PPD), and bleeding on probing (BOP). Nearly all patients showed a thin soft-tissue biotype. The analysis of the skeletal basic morphology of the alveolar bone revealed a narrow apical base in 18 patients, middle base in 7 patients, and broad base in 3 patients. Width of the KM increased significantly (p < 0.01) from 0.4 ± 0,5 mm to 4.3 ± 1.5 mm after STG and PPD was significantly (p < 0,01) reduced from 6.3 ± 2,3 mm to 4.1 ± 1.9 mm. A significant reduction (p < 0.01) in BOP was recorded. All patients reported a clinical improvement of the inflammatory symptoms at follow-up. The results of this study showed that the STG can be applied successfully as a surgical treatment of peri-implantitis. It remains unclear whether soft-tissue biotype or the skeletal basic morphology of the alveolar bone affects the outcome of this surgical treatment.

  4. Screening Newborns' Hearing Now Standard | NIH MedlinePlus the Magazine

    MedlinePlus

    ... Possible Hearing Problem Your Baby's Hearing and Communicative Development Checklist Communication Considerations —for parents of children with hearing loss Cochlear Implants —surgically implanted hearing ...

  5. 21 CFR 872.3645 - Subperiosteal implant material.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... intended to construct custom prosthetic devices which are surgically implanted into the lower or upper jaw... intended to provide support for prostheses, such as dentures. (b) Classification. Class II. ...

  6. Feasibility of Surgically Implanting Acoustic Tags into Pacific Herring

    USGS Publications Warehouse

    Hershberger, Paul K.; Gregg, Jacob L.; Seitz, A.C.; Norcross, Brenda L.; Payne, J.C.; Kagley, A.N.; Meloy, B

    2010-01-01

    Internally implanted acoustic tags represent a potentially valuable approach to assessing the seasonal migration and distribution patterns of Pacific herring Clupea palasii. We examined the feasibility of implanting two sizes of dummy acoustic tags (9 mm in diameter × 21 mm long, 1.6 g; and 7 mm in diameter × 18 mm long, 0.7 g) in Pacific herring that had been held in captivity for nearly a year and that ranged from 165 to 215 mm in fork length (FL) and from 41.6 to 142.6 g. Relatively low mortality (4%) and tag shedding (4%), as well as growth similar to that observed in control fish after 135 d, indicate that, with proper handling, Pacific herring are amenable to surgical implantation of acoustic tags.

  7. Surgical Tooth Implants, Combat and Field.

    DTIC Science & Technology

    1982-07-15

    design. The serrated root portion is alumina ceramic. The upper two parts of the implant (post and core and crown) are conventional dental materials...ceramic. The upper two parts of the implant (post and core and crown) are conventional dental materials, usually gold. Roots are produced by grinding...I1 Clinical Examples of Baboon Dental Implants . . . .. . . . .. 12 Clinical Chemistry and Hematology Results in Baboons. . . . . . . 20

  8. [Virtual Planning of Prosthetic Treatment of the Orbit].

    PubMed

    Veit, Johannes A; Thierauf, Julia; Egner, Kornelius; Wiggenhauser, Paul Severin; Friedrich, Daniel; Greve, Jens; Schuler, Patrick J; Hoffmann, Thomas K; Schramm, Alexander

    2017-06-01

    Optimal positioning of bone-anchored implants in the treatment of patients with orbital prosthesis is challenging. The definition of implant axis as well as the positioning of the implants is important to prevent failures in prosthetic rehabilitation in these patients. We performed virtual planning of enossal implants at a base of a standard fan beam CT scan using the software CoDiagnostiX™ (DentalWings, Montréal, Canada). By 3D-printing a surgical guide for drilling and implant insertion was manufactured (Med-610™, Stratasys, Rehovot, Israel). An orbital exenteration was performed in a patient after shrinkage of the eyelids 20 years after enucleation and radiation of the orbit due to rhabdomyosarcoma. 4 Vistafix-3 implants (Cochlear™, Cochlea, Centennial, USA) were primarily inserted after resection with the help of the 3D-surgical guide. Prosthetic rehabilitation could be achieved as preplanned to a predictable result. The individual prosthesis of the orbit showed good functional and esthetic outcome. The virtual 3D-planning of endosseous implants for prosthetic orbital and periorbital reconstruction is easy to use and facilitates optimal placement of implants especially in posttherapeutically altered anatomic situations. © Georg Thieme Verlag KG Stuttgart · New York.

  9. Maxillary "All-On-Four" treatment using zygomatic implants. A mechanical analysis.

    PubMed

    de Moraes, P H; Olate, S; Nóbilo, M de Arruda; Asprino, L; de Moraes, M; Barbosa, J de Albergaría

    2016-04-01

    Zygomatic implants may be used for dental rehabilitation in atrophic maxillae. The aim of this study was to establish experimentally the areas of stress distribution using 2 kinds of "All-On-Four" maxillary procedures. The best position to insert the implants was selected using polyurethane craniomaxillary models and surgical guides were made. Group 1 was designed with two posterior zygomatic implants and two conventional anterior implants, and group 2 with two posterior zygomatic implants and two anterior zygomatic implants. A titanium bar was built to link the 4 implants in both groups. Photoelastic replicas of these models were made and the implants were inserted using the surgical guides. An Instrom 4411 testing machine was used to perform a unilateral compressive loading at the level of the right first molar until 2mm of displacement was obtained. Group 1 showed a high strain concentration in the right lateral orbital region at the level of the apex of the zygomatic implant. Less strain was noticed at the apical levels of the conventional implants in the anterior sector and of the contralateral zygomatic implant. Group 2 showed high strains in the lateral inferior orbital area. The load was low in the alveolar bone sector. Zygomatic bone and paranasal structures are loaded at high levels when zygomatic implants are used to stabilize a full maxillary prosthodontic rehabilitation on 4 implants. The use of 4 zygomatic implants loads the alveolar bone to a lower extent and seems better suited from a mechanical point of view than the use of 2 zygomatic implants. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  10. Custom-designed orthopedic implants evaluated using finite element analysis of patient-specific computed tomography data: femoral-component case study

    PubMed Central

    Harrysson, Ola LA; Hosni, Yasser A; Nayfeh, Jamal F

    2007-01-01

    Background Conventional knee and hip implant systems have been in use for many years with good success. However, the custom design of implant components based on patient-specific anatomy has been attempted to overcome existing shortcomings of current designs. The longevity of cementless implant components is highly dependent on the initial fit between the bone surface and the implant. The bone-implant interface design has historically been limited by the surgical tools and cutting guides available; and the cost of fabricating custom-designed implant components has been prohibitive. Methods This paper describes an approach where the custom design is based on a Computed Tomography scan of the patient's joint. The proposed design will customize both the articulating surface and the bone-implant interface to address the most common problems found with conventional knee-implant components. Finite Element Analysis is used to evaluate and compare the proposed design of a custom femoral component with a conventional design. Results The proposed design shows a more even stress distribution on the bone-implant interface surface, which will reduce the uneven bone remodeling that can lead to premature loosening. Conclusion The proposed custom femoral component design has the following advantages compared with a conventional femoral component. (i) Since the articulating surface closely mimics the shape of the distal femur, there is no need for resurfacing of the patella or gait change. (ii) Owing to the resulting stress distribution, bone remodeling is even and the risk of premature loosening might be reduced. (iii) Because the bone-implant interface can accommodate anatomical abnormalities at the distal femur, the need for surgical interventions and fitting of filler components is reduced. (iv) Given that the bone-implant interface is customized, about 40% less bone must be removed. The primary disadvantages are the time and cost required for the design and the possible need for a surgical robot to perform the bone resection. Some of these disadvantages may be eliminated by the use of rapid prototyping technologies, especially the use of Electron Beam Melting technology for quick and economical fabrication of custom implant components. PMID:17854508

  11. Custom Titanium Ridge Augmentation Matrix (CTRAM): A Case Report.

    PubMed

    Connors, Christopher A; Liacouras, Peter C; Grant, Gerald T

    2016-01-01

    This is a case report of a custom titanium ridge augmentation matrix (CTRAM). Using cone beam computed tomography (CBCT), a custom titanium space-maintaining device was developed. Alveolar ridges were virtually augmented, a matrix was virtually designed, and the CTRAM was additively manufactured with titanium (Ti6Al4V). Two cases are presented that resulted in sufficient increased horizontal bone volume with successful dental implant placement. The CTRAM design allows for preoperative planning for increasing alveolar ridge dimensions to support dental implants, reduces surgical time, and prevents the need for a second surgical site to gain sufficient alveolar ridge bone volume for dental implant therapy.

  12. Osteodistraction With Dental Implant-Borne Devices for Bone Regeneration in Atrophied Premaxilla.

    PubMed

    Carlino, Francesco; Villani, Gian Piero; Berti, Andrea; Pantaleo, Giuseppe; Cortese, Antonio; Claudio, Pier Paolo

    2016-11-01

    Aim of this work is to present the evolution of an innovative technique for tooth/implant supported bone distraction, leading to proper oral rehabilitation in patients with atrophic alveolar bone, even when a complete premaxilla expansion is needed, or in patients in whom implants were already present, but inserted in wrong position.Distraction osteogenesis was selected because of its moderate invasiveness, the few surgical steps needed, and the proper cost/benefits balance. This procedure is particularly suited for young patients with remarkable aesthetic demands related to active social and working life, as for elderly patients expecting lower surgical stress and risks.

  13. Breast Implant-Associated Infections: The Role of the National Surgical Quality Improvement Program and the Local Microbiome.

    PubMed

    Cohen, Justin B; Carroll, Cathy; Tenenbaum, Marissa M; Myckatyn, Terence M

    2015-11-01

    The most common cause of surgical readmission after breast implant surgery remains infection. Six causative organisms are principally involved: Staphylococcus epidermidis and S. aureus, Escherichia, Pseudomonas, Propionibacterium, and Corynebacterium. The authors investigated the infection patterns and antibiotic sensitivities to characterize their local microbiome and determine ideal antibiotic selection. A retrospective review of 2285 consecutive implant-based breast procedures was performed. Included surgical procedures were immediate and delayed breast reconstruction, tissue expander exchange, and cosmetic augmentation. Patient demographics, chemotherapy and/or irradiation status, implant characteristics, explantation reason, time to infection, microbiological data, and antibiotic sensitivities were reviewed. Forty-seven patients (2.1 percent) required inpatient admission for antibiotics, operative explantation, or drainage by interventional radiology. The infection rate varied depending on surgical procedure, with the highest rate seen in mastectomy and immediate tissue expander reconstruction (6.1 percent). The mean time to explantation was 41 days. Only 50 percent of infections occurred within 30 days of the indexed National Surgical Quality Improvement Program operation. The most commonly isolated organisms were coagulase-negative Staphylococcus (27 percent), methicillin-sensitive S. aureus (25 percent), methicillin-resistant S. aureus (7 percent), Pseudomonas (7 percent), and Peptostreptococcus (7 percent). All Gram-positive organisms were sensitive to vancomycin, linezolid, tetracycline, and doxycycline; all Gram-negative organisms were sensitive to gentamicin and cefepime. Empiric antibiotics should be vancomycin (with the possible inclusion of gentamicin) based on their broad effectiveness against the authors' unique microbiome. Minor infections should be treated with tetracycline or doxycycline as a second-line agent. National Surgical Quality Improvement Program data are adequate for monitoring and comparing breast infections but certainly not comprehensive. Therapeutic, IV.

  14. [Clinical experience in osteoplastic material Allomatrix-implant and fibrin rich platelets use in surgical treatment of jaw radicular cysts].

    PubMed

    Kuz'minykh, I A

    2009-01-01

    Bones forming optimizators applying in surgical dentistry is an important element of jaw destructive processes successful treatment. Today use of osteoplastic materials on the collagen basis is widely spread. One of this challenge solution is FRP and Allomatrix-implant material applying to jaws during surgery operations. We described clinical investigation phase: the estimation of postoperative and remote results of treatment was carried out.

  15. [Role of endo-osseus implant in odonto-oral rehabilitation].

    PubMed

    Vanhakendover, S

    2003-01-01

    Dental implants have critically changed the restorative procedures available to edentulous patients. Biocompatible materials, precise surgical techniques and improved instrumentation give well trained practicioners various opportunities to achieve successful treatments. The necessity of combining full expertise in surgery and rational prosthetic planning with comprehensive occlusal management is emphasized. Recent advances in periodontal treatment of osseous and soft tissue defects, new grafting techniques and surgical approaches have dramatically enlarged the scope of oral implantology.

  16. Quality assurance: recommended guidelines for safe heating by capacitive-type heating technique to treat patients with metallic implants.

    PubMed

    Kato, Hirokazu; Kondo, Motoharu; Imada, Hajime; Kuroda, Masahiro; Kamimura, Yoshitsugu; Saito, Kazuyuki; Kuroda, Kagayaki; Ito, Koichi; Takahashi, Hideaki; Matsuki, Hidetoshi

    2013-05-01

    This article is a redissemination of the previous Japanese Quality Assurance Guide guidelines. Specific absorption rate and temperature distribution were investigated with respect to various aspects including metallic implant size and shape, insertion site, insertion direction, blood flow and heating power, and simulated results were compared with adverse reactions of patients treated by radio frequency capacitive-type heating. Recommended guidelines for safe heating methods for patients with metallic implants are presented based on our findings.

  17. First-in-Human Trial of a Novel Suprachoroidal Retinal Prosthesis

    PubMed Central

    Ayton, Lauren N.; Blamey, Peter J.; Guymer, Robyn H.; Luu, Chi D.; Nayagam, David A. X.; Sinclair, Nicholas C.; Shivdasani, Mohit N.; Yeoh, Jonathan; McCombe, Mark F.; Briggs, Robert J.; Opie, Nicholas L.; Villalobos, Joel; Dimitrov, Peter N.; Varsamidis, Mary; Petoe, Matthew A.; McCarthy, Chris D.; Walker, Janine G.; Barnes, Nick; Burkitt, Anthony N.; Williams, Chris E.; Shepherd, Robert K.; Allen, Penelope J.

    2014-01-01

    Retinal visual prostheses (“bionic eyes”) have the potential to restore vision to blind or profoundly vision-impaired patients. The medical bionic technology used to design, manufacture and implant such prostheses is still in its relative infancy, with various technologies and surgical approaches being evaluated. We hypothesised that a suprachoroidal implant location (between the sclera and choroid of the eye) would provide significant surgical and safety benefits for patients, allowing them to maintain preoperative residual vision as well as gaining prosthetic vision input from the device. This report details the first-in-human Phase 1 trial to investigate the use of retinal implants in the suprachoroidal space in three human subjects with end-stage retinitis pigmentosa. The success of the suprachoroidal surgical approach and its associated safety benefits, coupled with twelve-month post-operative efficacy data, holds promise for the field of vision restoration. Trial Registration Clinicaltrials.gov NCT01603576 PMID:25521292

  18. Transapical Implantation of a 2nd-Generation JenaValve Device in Patient with Extremely High Surgical Risk

    PubMed Central

    Mieres, Juan; Menéndez, Marcelo; Fernández-Pereira, Carlos; Rubio, Miguel; Rodríguez, Alfredo E.

    2015-01-01

    Transcatheter Aortic Valve Replacement (TAVR) is performed in patients who are poor surgical candidates. Many patients have inadequate femoral access, and alternative access sites have been used such as the transapical approach discussed in this paper. We present an elderly and fragile patient not suitable for surgery for unacceptable high risk, including poor ventricular function, previous myocardial infarction with percutaneous coronary intervention, pericardial effusion, and previous cardiac surgery with replacement of mechanical mitral valve. Transapical aortic valve replacement with a second-generation self-expanding JenaValve is performed. The JenaValve is a second-generation transapical TAVR valve consisting of a porcine root valve mounted on a low-profile nitinol stent. The valve is fully retrievable and repositionable. We discuss transapical access, implantation technique, and feasibility of valve implantation in this extremely high surgical risk patient. PMID:26346128

  19. Transapical Implantation of a 2nd-Generation JenaValve Device in Patient with Extremely High Surgical Risk.

    PubMed

    Mieres, Juan; Menéndez, Marcelo; Fernández-Pereira, Carlos; Rubio, Miguel; Rodríguez, Alfredo E

    2015-01-01

    Transcatheter Aortic Valve Replacement (TAVR) is performed in patients who are poor surgical candidates. Many patients have inadequate femoral access, and alternative access sites have been used such as the transapical approach discussed in this paper. We present an elderly and fragile patient not suitable for surgery for unacceptable high risk, including poor ventricular function, previous myocardial infarction with percutaneous coronary intervention, pericardial effusion, and previous cardiac surgery with replacement of mechanical mitral valve. Transapical aortic valve replacement with a second-generation self-expanding JenaValve is performed. The JenaValve is a second-generation transapical TAVR valve consisting of a porcine root valve mounted on a low-profile nitinol stent. The valve is fully retrievable and repositionable. We discuss transapical access, implantation technique, and feasibility of valve implantation in this extremely high surgical risk patient.

  20. Implantable, Ingestible Electronic Thermometer

    NASA Technical Reports Server (NTRS)

    Kleinberg, Leonard

    1987-01-01

    Small quartz-crystal-controlled oscillator swallowed or surgically implanted provides continuous monitoring of patient's internal temperature. Receiver placed near patient measures oscillator frequency, and temperature inferred from previously determined variation of frequency with temperature. Frequency of crystal-controlled oscillator varies with temperature. Circuit made very small and implanted or ingested to measure internal body temperature.

  1. The KineSpring® Knee Implant System: an implantable joint-unloading prosthesis for treatment of medial knee osteoarthritis

    PubMed Central

    Clifford, Anton G; Gabriel, Stefan M; O’Connell, Mary; Lowe, David; Miller, Larry E; Block, Jon E

    2013-01-01

    Symptomatic medial compartment knee osteoarthritis (OA) is the leading cause of musculoskeletal pain and disability in adults. Therapies intended to unload the medial knee compartment have yielded unsatisfactory results due to low patient compliance with conservative treatments and high complication rates with surgical options. There is no widely available joint-unloading treatment for medial knee OA that offers clinically important symptom alleviation, low complication risk, and high patient acceptance. The KineSpring® Knee Implant System (Moximed, Inc, Hayward, CA, USA) is a first-of-its-kind, implantable, extra-articular, extra-capsular prosthesis intended to alleviate knee OA-related symptoms by reducing medial knee compartment loading while overcoming the limitations of traditional joint-unloading therapies. Preclinical and clinical studies have demonstrated excellent prosthesis durability, substantial reductions in medial compartment and total joint loads, and clinically important improvements in OA-related pain and function. The purpose of this report is to describe the KineSpring System, including implant characteristics, principles of operation, indications for use, patient selection criteria, surgical technique, postoperative care, preclinical testing, and clinical experience. The KineSpring System has potential to bridge the gap between ineffective conservative treatments and irreversible surgical interventions for medial compartment knee OA. PMID:23717052

  2. Adjuvant Maneuvers for Residual Curvature Correction During Penile Prosthesis Implantation in Men with Peyronie's Disease.

    PubMed

    Berookhim, Boback M; Karpman, Edward; Carrion, Rafael

    2015-11-01

    The surgical treatment of comorbid erectile dysfunction and Peyronie's disease has long included the implantation of an inflatable penile prosthesis as well as a number of adjuvant maneuvers to address residual curvature after prosthesis placement. To review the various surgical options for addressing curvature after prosthesis placement, with specific attention paid to an original article by Wilson et al. reporting on modeling over a penile prosthesis for the management of Peyronie's disease. A literature review was performed analyzing articles reporting the management of penile curvature in patients undergoing implantation of an inflatable penile prosthesis. Reported improvement in Peyronie's deformity as well as the complication rate associated with the various surgical techniques described. Modeling is a well-established treatment modality among patients with Peyronie's disease undergoing penile prosthesis implantation. A variety of other adjuvant maneuvers to address residual curvature when modeling alone is insufficient has been presented in the literature. Over 20 years of experience with modeling over a penile prosthesis have proven the efficacy and safety of this treatment option, providing the surgeon a simple initial step for the management of residual curvature after penile implantation which allows for the use of additional adjuvant maneuvers in those with significant deformities. © 2015 International Society for Sexual Medicine.

  3. Median Sternotomy or Right Thoracotomy Techniques for Total Artificial Heart Implantation in Calves.

    PubMed

    Karimov, Jamshid H; Moazami, Nader; Sunagawa, Gengo; Kobayashi, Mariko; Byram, Nicole; Sale, Shiva; Such, Kimberly A; Horvath, David J; Golding, Leonard A R; Fukamachi, Kiyotaka

    2016-10-01

    The choice of optimal operative access technique for mechanical circulatory support device implantation ensures successful postoperative outcomes. In this study, we retrospectively evaluated the median sternotomy and lateral thoracotomy incisions for placement of the Cleveland Clinic continuous-flow total artificial heart (CFTAH) in a bovine model. The CFTAH was implanted in 17 calves (Jersey calves; weight range, 77.0-93.9 kg) through a median sternotomy (n = 9) or right thoracotomy (n = 8) for elective chronic implantation periods of 14, 30, or 90 days. Similar preoperative preparation, surgical techniques, and postoperative care were employed. Implantation of the CFTAH was successfully performed in all cases. Both methods provided excellent surgical field visualization. After device connection, however, the median sternotomy approach provided better visualization of the anastomoses and surgical lines for hemostasis confirmation and repair due to easier device displacement, which is severely limited following right thoracotomy. All four animals sacrificed after completion of the planned durations (up to 90 days) were operated through full median sternotomy. Our data demonstrate that both approaches provide excellent initial field visualization. Full median sternotomy provides larger viewing angles at the anastomotic suture line after device connection to inflow and outflow ports. Copyright © 2015 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  4. Delayed Propionibacterium acnes surgical site infections occur only in the presence of an implant

    PubMed Central

    Shiono, Yuta; Ishii, Ken; Nagai, Shigenori; Kakinuma, Hiroaki; Sasaki, Aya; Funao, Haruki; Kuramoto, Tetsuya; Yoshioka, Kenji; Ishihama, Hiroko; Isogai, Norihiro; Takeshima, Kenichiro; Tsuji, Takashi; Okada, Yasunori; Koyasu, Shigeo; Nakamura, Masaya; Toyama, Yoshiaki; Aizawa, Mamoru; Matsumoto, Morio

    2016-01-01

    Whether Propionibacterium acnes (P. acnes) causes surgical-site infections (SSI) after orthopedic surgery is controversial. We previously reported that we frequently find P. acnes in intraoperative specimens, yet none of the patients have clinically apparent infections. Here, we tracked P. acnes for 6 months in a mouse osteomyelitis model. We inoculated P. acnes with an implant into the mouse femur in the implant group; the control group was treated with the bacteria but no implant. We then observed over a 6-month period using optical imaging system. During the first 2 weeks, bacterial signals were detected in the femur in the both groups. The bacterial signal completely disappeared in the control group within 28 days. Interestingly, in the implant group, bacterial signals were still present 6 months after inoculation. Histological and scanning electron-microscope analyses confirmed that P. acnes was absent from the control group 6 months after inoculation, but in the implant group, the bacteria had survived in a biofilm around the implant. PCR analysis also identified P. acnes in the purulent effusion from the infected femurs in the implant group. To our knowledge, this is the first report showing that P. acnes causes SSI only in the presence of an implant. PMID:27615686

  5. Implants for draining neovascular glaucoma.

    PubMed Central

    Molteno, A C; Van Rooyen, M M; Bartholomew, R S

    1977-01-01

    The implant design, surgical technique, and pharmacological methods of controlling bleb fibrosis, used to treat neovascular glaucoma, are described, together with the results of 14 operations performed on 12 eyes. Images PMID:843508

  6. Development and Assessment of a 3D-Printed Scaffold with rhBMP-2 for an Implant Surgical Guide Stent and Bone Graft Material: A Pilot Animal Study.

    PubMed

    Bae, Ji Cheol; Lee, Jin-Ju; Shim, Jin-Hyung; Park, Keun-Ho; Lee, Jeong-Seok; Bae, Eun-Bin; Choi, Jae-Won; Huh, Jung-Bo

    2017-12-16

    In this study, a new concept of a 3D-printed scaffold was introduced for the accurate placement of an implant and the application of a recombinant human bone morphogenetic protein-2 (rhBMP-2)-loaded bone graft. This preliminary study was conducted using two adult beagles to evaluate the 3D-printed polycaprolactone (PCL)/ β -tricalcium phosphate ( β -TCP)/bone decellularized extracellular matrix (bdECM) scaffold conjugated with rhBMP-2 for the simultaneous use as an implant surgical guide stent and bone graft material that promotes new bone growth. Teeth were extracted from the mandible of the beagle model and scanned by computed tomography (CT) to fabricate a customized scaffold that would fit the bone defect. After positioning the implant guide scaffold, the implant was placed and rhBMP-2 was injected into the scaffold of the experimental group. The two beagles were sacrificed after three months. The specimen block was obtained and scanned by micro-CT. Histological analysis showed that the control and experimental groups had similar new bone volume (NBV, %) but the experimental group with BMP exhibited a significantly higher bone-to-implant contact ratio (BIC, %). Within the limitations of this preliminary study, a 3D-printed scaffold conjugated with rhBMP-2 can be used simultaneously as an implant surgical guide and a bone graft in a large bone defect site. Further large-scale studies will be needed to confirm these results.

  7. Cochlear implant surgery in patients more than seventy-nine years old.

    PubMed

    Eshraghi, Adrien A; Rodriguez, Michael; Balkany, Thomas J; Telischi, Fred F; Angeli, Simon; Hodges, Annelle V; Adil, Eelam

    2009-06-01

    To evaluate the surgical complications, auditory performance, and hearing handicap following cochlear implantation in patients greater than 79 years of age. Retrospective trial, tertiary referral center. The study group was comprised of 21 patients implanted after 79 years of age from 1996 through 2006 with follow-ups past their 8th decade. Pre-op evaluation consisted of pure-tone audiometry and speech discrimination scores (Hearing in Noise Test and City University of New York sentence test). The results of these tests were compared to similar tests taken post-op. A validated hearing handicap questionnaire was used to evaluate the outcome. There were no permanent medical or surgical complications. However, two patients developed exacerbations of previous comorbid conditions (i.e., urinary retention and acute delirium). Implanted patients experienced a significant improvement in audiologic performance, post-op pure tone average, and post-op speech scores (P < .001). A majority of them were able to use the phone and reported that the cochlear implant was of great benefit to them. The post-op hearing handicap inventory for the elderly demonstrated a significant decrease of hearing handicap scores. This is the first study to focus on a patient group this advanced in age. With increasing life expectancy, we should begin to stratify risk versus benefit of cochlear implantation in this age group. Cochlear implantation improved audiologic performance and the quality of life in patients older than 79 years old. There were no permanent medical or surgical complications. Chronic pain and temporary vertigo were the most common complications reported in this elderly group. Laryngoscope, 2009.

  8. The impact of the fabrication method on the three-dimensional accuracy of an implant surgery template.

    PubMed

    Matta, Ragai-Edward; Bergauer, Bastian; Adler, Werner; Wichmann, Manfred; Nickenig, Hans-Joachim

    2017-06-01

    The use of a surgical template is a well-established method in advanced implantology. In addition to conventional fabrication, computer-aided design and computer-aided manufacturing (CAD/CAM) work-flow provides an opportunity to engineer implant drilling templates via a three-dimensional printer. In order to transfer the virtual planning to the oral situation, a highly accurate surgical guide is needed. The aim of this study was to evaluate the impact of the fabrication method on the three-dimensional accuracy. The same virtual planning based on a scanned plaster model was used to fabricate a conventional thermo-formed and a three-dimensional printed surgical guide for each of 13 patients (single tooth implants). Both templates were acquired individually on the respective plaster model using an optical industrial white-light scanner (ATOS II, GOM mbh, Braunschweig, Germany), and the virtual datasets were superimposed. Using the three-dimensional geometry of the implant sleeve, the deviation between both surgical guides was evaluated. The mean discrepancy of the angle was 3.479° (standard deviation, 1.904°) based on data from 13 patients. Concerning the three-dimensional position of the implant sleeve, the highest deviation was in the Z-axis at 0.594 mm. The mean deviation of the Euclidian distance, dxyz, was 0.864 mm. Although the two different fabrication methods delivered statistically significantly different templates, the deviations ranged within a decimillimeter span. Both methods are appropriate for clinical use. Copyright © 2017 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  9. Surgical factors in pediatric cochlear implantation and their early effects on electrode activation and functional outcomes.

    PubMed

    Francis, Howard W; Buchman, Craig A; Visaya, Jiovani M; Wang, Nae-Yuh; Zwolan, Teresa A; Fink, Nancy E; Niparko, John K

    2008-06-01

    To assess the impact of surgical factors on electrode status and early communication outcomes in young children in the first 2 years of cochlear implantation. Prospective multicenter cohort study. Six tertiary referral centers. Children 5 years or younger before implantation with normal nonverbal intelligence. Cochlear implant operations in 209 ears of 188 children. Percent active channels, auditory behavior as measured by the Infant Toddler Meaningful Auditory Integration Scale/Meaningful Auditory Integration Scale and Reynell receptive language scores. Stable insertion of the full electrode array was accomplished in 96.2% of ears. At least 75% of electrode channels were active in 88% of ears. Electrode deactivation had a significant negative effect on Infant Toddler Meaningful Auditory Integration Scale/Meaningful Auditory Integration Scale scores at 24 months but no effect on receptive language scores. Significantly fewer active electrodes were associated with a history of meningitis. Surgical complications requiring additional hospitalization and/or revision surgery occurred in 6.7% of patients but had no measurable effect on the development of auditory behavior within the first 2 years. Negative, although insignificant, associations were observed between the need for perioperative revision of the device and 1) the percent of active electrodes and 2) the receptive language level at 2-year follow-up. Activation of the entire electrode array is associated with better early auditory outcomes. Decrements in the number of active electrodes and lower gains of receptive language after manipulation of the newly implanted device were not statistically significant but may be clinically relevant, underscoring the importance of surgical technique and the effective placement of the electrode array.

  10. Complete Surgical Excision Is Essential for the Management of Patients With Breast Implant-Associated Anaplastic Large-Cell Lymphoma.

    PubMed

    Clemens, Mark W; Medeiros, L Jeffrey; Butler, Charles E; Hunt, Kelly K; Fanale, Michelle A; Horwitz, Steven; Weisenburger, Dennis D; Liu, Jun; Morgan, Elizabeth A; Kanagal-Shamanna, Rashmi; Parkash, Vinita; Ning, Jing; Sohani, Aliyah R; Ferry, Judith A; Mehta-Shah, Neha; Dogan, Ahmed; Liu, Hui; Thormann, Nora; Di Napoli, Arianna; DiNapoli, Arianna; Lade, Stephen; Piccolini, Jorge; Reyes, Ruben; Williams, Travis; McCarthy, Colleen M; Hanson, Summer E; Nastoupil, Loretta J; Gaur, Rakesh; Oki, Yasuhiro; Young, Ken H; Miranda, Roberto N

    2016-01-10

    Breast implant-associated anaplastic large-cell lymphoma (BI-ALCL) is a rare type of T-cell lymphoma that arises around breast implants. The optimal management of this disease has not been established. The goal of this study is to evaluate the efficacy of different therapies used in patients with BI-ALCL to determine an optimal treatment approach. In this study, we applied strict criteria to pathologic findings, assessed therapies used, and conducted a clinical follow-up of 87 patients with BI-ALCL, including 50 previously reported in the literature and 37 unreported. A Prentice, Williams, and Peterson model was used to assess the rate of events for each therapeutic intervention. The median and mean follow-up times were 45 and 30 months, respectively (range, 3 to 217 months). The median overall survival (OS) time after diagnosis of BI-ALCL was 13 years, and the OS rate was 93% and 89% at 3 and 5 years, respectively. Patients with lymphoma confined by the fibrous capsule surrounding the implant had better event-free survival (EFS) and OS than did patients with lymphoma that had spread beyond the capsule (P = .03). Patients who underwent a complete surgical excision that consisted of total capsulectomy with breast implant removal had better OS (P = .022) and EFS (P = .014) than did patients who received partial capsulectomy, systemic chemotherapy, or radiation therapy. Surgical management with complete surgical excision is essential to achieve optimal EFS in patients with BI-ALCL. © 2015 by American Society of Clinical Oncology.

  11. Transcatheter Aortic Valve-in-Valve Procedure in Patients with Bioprosthetic Structural Valve Deterioration

    PubMed Central

    Reul, Ross M.; Ramchandani, Mahesh K.; Reardon, Michael J.

    2017-01-01

    Surgical aortic valve replacement is the gold standard procedure to treat patients with severe, symptomatic aortic valve stenosis or insufficiency. Bioprosthetic valves are used for surgical aortic valve replacement with a much greater prevalence than mechanical valves. However, bioprosthetic valves may fail over time because of structural valve deterioration; this often requires intervention due to severe bioprosthetic valve stenosis or regurgitation or a combination of both. In select patients, transcatheter aortic valve replacement is an alternative to surgical aortic valve replacement. Transcatheter valve-in-valve (ViV) replacement is performed by implanting a transcatheter heart valve within a failing bioprosthetic valve. The transcatheter ViV operation is a less invasive procedure compared with reoperative surgical aortic valve replacement, but it has been associated with specific complications and requires extensive preoperative work-up and planning by the heart team. Data from experimental studies and analyses of results from clinical procedures have led to strategies to improve outcomes of these procedures. The type, size, and implant position of the transcatheter valve can be optimized for individual patients with knowledge of detailed dimensions of the surgical valve and radiographic and echocardiographic measurements of the patient's anatomy. Understanding the complexities of the ViV procedure can lead surgeons to make choices during the original surgical valve implantation that can make a future ViV operation more technically feasible years before it is required. PMID:29743998

  12. 3D Volume Rendering and 3D Printing (Additive Manufacturing).

    PubMed

    Katkar, Rujuta A; Taft, Robert M; Grant, Gerald T

    2018-07-01

    Three-dimensional (3D) volume-rendered images allow 3D insight into the anatomy, facilitating surgical treatment planning and teaching. 3D printing, additive manufacturing, and rapid prototyping techniques are being used with satisfactory accuracy, mostly for diagnosis and surgical planning, followed by direct manufacture of implantable devices. The major limitation is the time and money spent generating 3D objects. Printer type, material, and build thickness are known to influence the accuracy of printed models. In implant dentistry, the use of 3D-printed surgical guides is strongly recommended to facilitate planning and reduce risk of operative complications. Copyright © 2018 Elsevier Inc. All rights reserved.

  13. Surgical management of fractured orthodontic mini- implant- a case report.

    PubMed

    Desai, Manthan; Jain, Anoop; Sumra, Nida

    2015-01-01

    The idea of absolute anchorage has always been an elusive goal for clinicians. Orthodontic mini-implants or temporary anchorage devices allow tooth movements previously thought to be impossible or difficult. Although extensive literature exists on use of temporary anchorage devices, their failures have been hardly focused upon, especially implant fracture. The following case report describes successful management of fractured orthodontic mini-implant.

  14. Hearing Loss and Older Adults

    MedlinePlus

    ... are the most common ones: Hearing aids are electronic instruments you wear in or behind your ear. ... information.) Cochlear (COKE-lee-ur) implants are small electronic devices surgically implanted in the inner ear that ...

  15. Prophylactic Antibiotics for Enucleation and Evisceration: A Retrospective Study and Systematic Literature Review.

    PubMed

    Pariseau, Brett; Fox, Barry; Dutton, Jonathan J

    To report surgical site infection (SSI) rates of eviscerations and enucleations with implants performed without perioperative intravenous (IV) antibiotics or postoperative oral antibiotics, and to give SSI prevention recommendations. A single-center retrospective chart review was performed after obtaining institutional review board approval. Charts were found by Current Procedural Terminology codes. Demographics, surgical indication, procedure, implant, antibiotic use, and postoperative course were recorded. SSIs occurring within 30 days after surgery were reviewed and postoperative infection rates were determined. Four hundred eighty-one cases from January 1999 to December 2015 were analyzed. There were 102 eviscerations with implants, 314 enucleations with implants, 23 enucleations without implants, 23 implant exchanges, 15 implants placed secondarily after enucleation, and 4 implant removals. Seventy cases (14.6%) were given perioperative IV antibiotics, and in this group one periorbital infection occurred unrelated to orbital surgery (1.4%). Of the 411 cases (85.4%) not given perioperative IV antibiotics, 1 of 87 eviscerations with implants developed an SSI (1.1%), 2 of 273 enucleations with implants developed SSIs (0.7%), and none of the 13 enucleations without implants developed SSIs. To our knowledge, this is the first published case series reporting SSI rates of enucleations and eviscerations with implants performed without perioperative IV antibiotics or postoperative oral antibiotics. With infection rates comparing favorably to other case series where antibiotics were given, the routine use of perioperative IV antibiotics and postoperative oral antibiotics for enucleations and eviscerations may not be indicated.

  16. ANALYSIS OF SURGICAL SITE INFECTIONS IN PEDIATRIC PATIENTS AFTER ORTHOPEDIC SURGERY: A CASE-CONTROL STUDY

    PubMed Central

    Chagas, Mariana de Queiroz Leite; Costa, Ana Maria Magalhães; Mendes, Pedro Henrique Barros; Gomes, Saint Clair

    2017-01-01

    ABSTRACT Objectives: To describe the rate of surgical site infections in children undergoing orthopedic surgery in centers of excellence and analyze the patients’ profiles. Methods: Medical records of pediatric patients undergoing orthopedic surgery in the Jamil Haddad National Institute of Traumatology and Orthopedics from January 2012 to December 2013 were analyzed and monitored for one year. Patients diagnosed with surgical site infection were matched with patients without infection by age, date of admission, field of orthopedic surgery and type of surgical procedure. Patient, surgical and follow-up variables were examined. Descriptive, bivariate and correspondence analyses were performed to evaluate the patients’ profiles. Results: 347 surgeries and 10 surgical site infections (2.88%) were identified. There was association of infections with age - odds ratio (OR) 11.5 (confidence interval - 95%CI 1.41-94.9) -, implant - OR 7.3 (95%CI 1.46-36.3) -, preoperative period - OR 9.8 (95%CI 1.83-53.0), and length of hospitalization - OR 20.6 (95%CI 3.7-114.2). The correspondence analysis correlated the infection and preoperative period, weight, weight Z-score, age, implant, type of surgical procedure, and length of hospitalization. Average time to diagnosis of infection occurred 26.5±111.46 days after surgery. Conclusions: The rate of surgical site infection was 2.88%, while higher in children over 24 months of age who underwent surgical implant procedures and had longer preoperative periods and lengths of hospitalization. This study identified variables for the epidemiological surveillance of these events in children. Available databases and appropriate analysis methods are essential to monitor and improve the quality of care offered to the pediatric population. PMID:28977312

  17. Outcomes of Ahmed glaucoma valve implantation in advanced primary congenital glaucoma with previous surgical failure.

    PubMed

    Huang, Jingjing; Lin, Jialiu; Wu, Ziqiang; Xu, Hongzhi; Zuo, Chengguo; Ge, Jian

    2015-01-01

    The purpose of this study was to evaluate the intermediate surgical results of Ahmed glaucoma valve (AGV) implantation in patients less than 7 years of age, with advanced primary congenital glaucoma who have failed previous surgeries. Consecutive patients with advanced primary congenital glaucoma that failed previous operations and had undergone subsequent AGV implantation were evaluated retrospectively. Surgical success was defined as 1) intraocular pressure (IOP) ≥6 and ≤21 mmHg; 2) IOP reduction of at least 30% relative to preoperative values; and 3) without the need for additional surgical intervention for IOP control, loss of light perception, or serious complications. Fourteen eyes of eleven patients were studied. Preoperatively, the average axial length was 27.71±1.52 (25.56-30.80) mm, corneal diameter was 14.71±1.07 (13.0-16.0) mm, cup-to-disc ratio was 0.95±0.04 (0.9-1.0), and IOP was 39.5±5.7 (30-55) mmHg. The mean follow-up time was 18.29±10.96 (5-44, median 18) months. There were significant reductions in IOPs and the number of glaucoma medications (P<0.001) postoperatively. The IOPs after operation were 11.3±3.4, 13.6±5.1, 16.3±2.7, and 16.1±2.6 mmHg at 1 month, 6 months, 12 months, and 18 months, respectively. Kaplan-Meier estimates of the cumulative probability of valve success were 85.7%, 71.4%, and 71.4% at 6, 12, and 18 months, respectively. Severe surgical complications, including erosion of tube, endophthalmitis, retinal detachment, choroidal detachment, and delayed suprachoroidal hemorrhage, occurred in 28.6% cases. AGV implantation remains a viable option for patients with advanced primary congenital glaucoma unresponsive to previous surgical intervention, despite a relatively high incidence of severe surgical complications.

  18. Outcomes of Ahmed glaucoma valve implantation in advanced primary congenital glaucoma with previous surgical failure

    PubMed Central

    Huang, Jingjing; Lin, Jialiu; Wu, Ziqiang; Xu, Hongzhi; Zuo, Chengguo; Ge, Jian

    2015-01-01

    Purpose The purpose of this study was to evaluate the intermediate surgical results of Ahmed glaucoma valve (AGV) implantation in patients less than 7 years of age, with advanced primary congenital glaucoma who have failed previous surgeries. Patients and methods Consecutive patients with advanced primary congenital glaucoma that failed previous operations and had undergone subsequent AGV implantation were evaluated retrospectively. Surgical success was defined as 1) intraocular pressure (IOP) ≥6 and ≤21 mmHg; 2) IOP reduction of at least 30% relative to preoperative values; and 3) without the need for additional surgical intervention for IOP control, loss of light perception, or serious complications. Results Fourteen eyes of eleven patients were studied. Preoperatively, the average axial length was 27.71±1.52 (25.56–30.80) mm, corneal diameter was 14.71±1.07 (13.0–16.0) mm, cup-to-disc ratio was 0.95±0.04 (0.9–1.0), and IOP was 39.5±5.7 (30–55) mmHg. The mean follow-up time was 18.29±10.96 (5–44, median 18) months. There were significant reductions in IOPs and the number of glaucoma medications (P<0.001) postoperatively. The IOPs after operation were 11.3±3.4, 13.6±5.1, 16.3±2.7, and 16.1±2.6 mmHg at 1 month, 6 months, 12 months, and 18 months, respectively. Kaplan–Meier estimates of the cumulative probability of valve success were 85.7%, 71.4%, and 71.4% at 6, 12, and 18 months, respectively. Severe surgical complications, including erosion of tube, endophthalmitis, retinal detachment, choroidal detachment, and delayed suprachoroidal hemorrhage, occurred in 28.6% cases. Conclusion AGV implantation remains a viable option for patients with advanced primary congenital glaucoma unresponsive to previous surgical intervention, despite a relatively high incidence of severe surgical complications. PMID:26082610

  19. Clinical efficacy analysis of Ahmed glaucoma valve implantation in neovascular glaucoma and influencing factors

    PubMed Central

    He, Ye; Tian, Ying; Song, Weitao; Su, Ting; Jiang, Haibo; Xia, Xiaobo

    2017-01-01

    Abstract This study aimed to evaluate the efficacy of Ahmed glaucoma valve (AGV) implantation in treating neovascular glaucoma (NVG) and to analyze the factors influencing the surgical success rate. This is a retrospective review of 40 eyes of 40 NVG patients who underwent AGV implantation at Xiangya Hospital of Central South University, China, between January 2014 and December 2016. Pre- and postoperative intraocular pressure (IOP), visual acuity, surgical success rate, medications, and complications were observed. Surgical success criteria were defined as IOP ≤21 and >6 mm Hg with or without additional medications. Kaplan–Meier survival curves and Multivariate cox regression analysis were used to examine success rates and risk factors for surgical outcomes. The mean follow-up period was 8.88 ± 3.12 months (range: 3–17). IOP declined at each visit postoperatively and it was statistically significant (P < .001). An average of 3.55 ± 0.86 drugs was applied preoperatively, while an average of 0.64 ± 0.90 drugs was used postoperatively, with the difference being of statistical significance (P < .05). The complete surgical success rate of 3, 6, and 12 months after the operation was 85%, 75%, and 65%, respectively. Meanwhile, the qualified success rate of 3, 6, and 12 months after the operation was 85%, 80%, and 77.5%, respectively. The multivariate cox regression analysis showed that age (hazard ratio: 3.717, 7.246; 95% confidence interval: 1.149–12.048, 1.349–38.461; P = .028, .021) was influencing factors for complete success rate and qualified success rate among all NVG patients. Gender, previous operation history, primary disease, and preoperative IOP were found to be not significant. AGV implantation is an effective and safe surgical method to treat NVG. Age is an important factor influencing the surgical success rate. PMID:29049253

  20. Outcomes of Cutaneous Scar Revision During Surgical Implant Removal in Children with Cerebral Palsy.

    PubMed

    Davids, Jon R; Diaz, Kevin; Leba, Thu-Ba; Adams, Samuel; Westberry, David E; Bagley, Anita M

    2016-08-17

    Children who have had surgery involving the placement of an implant frequently undergo a subsequent surgery for hardware removal. The cosmesis of surgical scars following initial and subsequent surgeries is unpredictable. Scar incision (subsequent surgical incision through the initial scar) or excision (around the initial scar) is selected on the basis of the quality of the initial scar. The outcomes following these techniques have not been determined. This prospective, consecutive case series was designed to compare outcomes following surgical scar incision versus excision at the time of implant removal in children with cerebral palsy. Photographs of the scars were made preoperatively and at 6 and 12 months following implant removal and were graded for scar quality utilizing the modified Stony Brook Scar Evaluation Scale (SBSES). Parental assessment of scar appearance was performed at the same time points utilizing a visual analog cosmetic scale (VACS). The scars that were selected for incision had significantly worse SBSES scores at 6 and 12 months following the second surgery compared with preoperative values. However, parents' VACS scores of the incised scars, although worse at 6 months, were comparable with preoperative scores at 12 months. Scars that were selected for excision had significantly worse SBSES scores at 6 months but scores that were comparable with preoperative values at 12 months. VACS scores for the excised scars were comparable at the 3 time points. Surgical incisions that initially healed with good scar quality generally healed well (from the parents' perspective) following subsequent incision through the previous scar. Surgical incisions that initially healed with poor scar quality did not heal better following excision of the previous scar. In such situations, surgical excision of the existing scar should occur in conjunction with additional adjuvant therapies to improve cosmesis. Therapeutic Level II. See Instructions for Authors for a complete description of levels of evidence. Copyright © 2016 by The Journal of Bone and Joint Surgery, Incorporated.

  1. From implant planning to surgical execution: an integrated approach for surgery in oral implantology.

    PubMed

    Chiarelli, Tommaso; Franchini, Federico; Lamma, Achille; Lamma, Evelina; Sansoni, Tommaso

    2012-03-01

    Using oral implantology software and transferring the preoperative planning into a stereolithographic model, prosthodontists can produce the related surgical guide. This procedure has some disadvantages: bone-supported stent invasiveness, lack of references due to scattering and non-negligible stereolithography cost. An alternative solution is presented that provides an ideal surgical stent (not invasive, precise, and cheap) as a result. This work focuses on the third phase of a fully 3D approach to oral implant planning, that starts by CT scanning a patient who wears a markers-equipped radiological stent, continues exploiting built-on-purpose preoperative planning software, and finishes producing the ideal surgical template. A 5-axes bur-equipped robot has been designed able to reproduce the milling vectors planned by the software. Software-robot interfacing has been achieved properly matching the stent reference frame and the software and robot coordinate systems. Invasiveness has been avoided achieving the surgical stent from the mucosa-supported radiological mask wax-up. Scattering is ignored because of the surgical stent independency from the bone structure radiography. Production cost has been strongly reduced by avoiding the stereolithographic model. Finally, software-robot interfacing precision has been validated comparing digitally a multi-marker base and its planning transfer. Average position and orientation errors (respectively 0.283 mm ± 0.073 mm and 1.798° ± 0.496°) were significantly better than those achieved using methods based on stereolithography (respectively, 1.45 mm ± 1.42 mm and 7.25° ± 2.67°, with a general best maximum translation discrepancy of about 1.1 mm). This paper describes the last step of a fully 3D approach in which implant planning can be done in a 3D environment, and the correct position, orientation and depth of the planned implants are easily computed and transferred to the surgical phase. Copyright © 2011 John Wiley & Sons, Ltd.

  2. Patient-Specific Surgical Implants Made of 3D Printed PEEK: Material, Technology, and Scope of Surgical Application

    PubMed Central

    Okolo, Brando; Popp, Uwe

    2018-01-01

    Additive manufacturing (AM) is rapidly gaining acceptance in the healthcare sector. Three-dimensional (3D) virtual surgical planning, fabrication of anatomical models, and patient-specific implants (PSI) are well-established processes in the surgical fields. Polyetheretherketone (PEEK) has been used, mainly in the reconstructive surgeries as a reliable alternative to other alloplastic materials for the fabrication of PSI. Recently, it has become possible to fabricate PEEK PSI with Fused Filament Fabrication (FFF) technology. 3D printing of PEEK using FFF allows construction of almost any complex design geometry, which cannot be manufactured using other technologies. In this study, we fabricated various PEEK PSI by FFF 3D printer in an effort to check the feasibility of manufacturing PEEK with 3D printing. Based on these preliminary results, PEEK can be successfully used as an appropriate biomaterial to reconstruct the surgical defects in a “biomimetic” design. PMID:29713642

  3. Patient-Specific Surgical Implants Made of 3D Printed PEEK: Material, Technology, and Scope of Surgical Application.

    PubMed

    Honigmann, Philipp; Sharma, Neha; Okolo, Brando; Popp, Uwe; Msallem, Bilal; Thieringer, Florian M

    2018-01-01

    Additive manufacturing (AM) is rapidly gaining acceptance in the healthcare sector. Three-dimensional (3D) virtual surgical planning, fabrication of anatomical models, and patient-specific implants (PSI) are well-established processes in the surgical fields. Polyetheretherketone (PEEK) has been used, mainly in the reconstructive surgeries as a reliable alternative to other alloplastic materials for the fabrication of PSI. Recently, it has become possible to fabricate PEEK PSI with Fused Filament Fabrication (FFF) technology. 3D printing of PEEK using FFF allows construction of almost any complex design geometry, which cannot be manufactured using other technologies. In this study, we fabricated various PEEK PSI by FFF 3D printer in an effort to check the feasibility of manufacturing PEEK with 3D printing. Based on these preliminary results, PEEK can be successfully used as an appropriate biomaterial to reconstruct the surgical defects in a "biomimetic" design.

  4. Evaluation of vaginal implants for mule deer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Garrott, R.A.; Bartmann, R.M.

    1984-01-01

    It is difficult to obtain information on the biology of the mule deer (Odocoileus hemionus) during the first several months of life because of the seclusive nature of fawns. Radio-transmitter implants were placed in the vaginas of mule deer to facilitate determining the time and location of parturition and to evaluate the effects on dams in the Piceance Basin, northwest Colorado.

  5. Characterization of In-Body to On-Body Wireless Radio Frequency Link for Upper Limb Prostheses.

    PubMed

    Stango, Antonietta; Yazdandoost, Kamya Yekeh; Negro, Francesco; Farina, Dario

    2016-01-01

    Wireless implanted devices can be used to interface patients with disabilities with the aim of restoring impaired motor functions. Implanted devices that record and transmit electromyographic (EMG) signals have been applied for the control of active prostheses. This simulation study investigates the propagation losses and the absorption rate of a wireless radio frequency link for in-to-on body communication in the medical implant communication service (MICS) frequency band to control myoelectric upper limb prostheses. The implanted antenna is selected and a suitable external antenna is designed. The characterization of both antennas is done by numerical simulations. A heterogeneous 3D body model and a 3D electromagnetic solver have been used to model the path loss and to characterize the specific absorption rate (SAR). The path loss parameters were extracted and the SAR was characterized, verifying the compliance with the guideline limits. The path loss model has been also used for a preliminary link budget analysis to determine the feasibility of such system compliant with the IEEE 802.15.6 standard. The resulting link margin of 11 dB confirms the feasibility of the system proposed.

  6. Characterization of In-Body to On-Body Wireless Radio Frequency Link for Upper Limb Prostheses

    PubMed Central

    Stango, Antonietta; Yazdandoost, Kamya Yekeh; Negro, Francesco; Farina, Dario

    2016-01-01

    Wireless implanted devices can be used to interface patients with disabilities with the aim of restoring impaired motor functions. Implanted devices that record and transmit electromyographic (EMG) signals have been applied for the control of active prostheses. This simulation study investigates the propagation losses and the absorption rate of a wireless radio frequency link for in-to-on body communication in the medical implant communication service (MICS) frequency band to control myoelectric upper limb prostheses. The implanted antenna is selected and a suitable external antenna is designed. The characterization of both antennas is done by numerical simulations. A heterogeneous 3D body model and a 3D electromagnetic solver have been used to model the path loss and to characterize the specific absorption rate (SAR). The path loss parameters were extracted and the SAR was characterized, verifying the compliance with the guideline limits. The path loss model has been also used for a preliminary link budget analysis to determine the feasibility of such system compliant with the IEEE 802.15.6 standard. The resulting link margin of 11 dB confirms the feasibility of the system proposed. PMID:27764182

  7. Use of Metallic Endosseous Implants as a Tooth Substitute.

    DTIC Science & Technology

    1979-06-01

    exposed in the oral cavity and placed in function with the opposing dentition iBACKGROUND The development of a dental implant that will serve as a...contract year was spent in testing the dental implant as a single tooth replacement. The ultimate goal of this implant study was to develop a free-standing...to read and sign an informed consent form. SURGICAL PROCEDURES The dental implant was inserted into the edentulous area using the exact procedures as

  8. The impact of glucocorticosteroids administered for systemic diseases on the osseointegration and survival of dental implants placed without bone grafting-A retrospective study in 31 patients.

    PubMed

    Petsinis, Vassilis; Kamperos, Georgios; Alexandridi, Foteini; Alexandridis, Konstantinos

    2017-08-01

    To evaluate the impact of glucocorticosteroids, administered for the treatment of systemic diseases, on the osseointegration and survival of dental implants placed without bone grafting. A retrospective study was conducted in search of patients treated with dental implants while receiving glucocorticosteroid therapy for various systemic diseases. In these cases, a conventional two-stage surgical protocol was used, without bone regeneration procedures. The osseointegration was clinically and radiographically tested at the uncovering of the implants. The follow-up after loading was set at a minimum of 3 years. A total of 31 patients were included in the study. Of the 105 dental implants placed, 104 were osseointegrated (99%). No bone absorption was radiographically noted at the uncovering of the osseointegrated implants. All of the osseointegrated implants were successfully loaded for the prosthetic restoration. The mean follow-up period after loading was 71 months, with an implant survival rate of 99%. Glucocorticosteroid intake for systemic diseases does not have a significant impact on the osseointegration and the 3-year survival of dental implants placed with a conventional two-stage surgical protocol and without bone grafting. Therefore, it should not be considered a contraindication for dental implant placement. Copyright © 2017 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  9. Habitat use and movement patterns by adult saugers from fall to summer in an unimpounded small-river system

    USGS Publications Warehouse

    Kuhn, K.M.; Hubert, W.A.; Johnson, K.; Oberlie, D.; Dufek, D.

    2008-01-01

    The Little Wind River drainage in Wyoming is a relatively small unimpounded river system inhabited by native saugers Sander canadensis. Radio telemetry was used to assess habitat use and movement patterns by adult saugers in the river system from fall through early summer. Fifty-four adult saugers were captured during fall 2004, surgically implanted with radio transmitters, and tracked through mid-July 2005. Tagged saugers selected large and deep pools. Such pools were abundant throughout the Little Wind River system and led to saugers being widely dispersed from fall to early spring. During fall, winter, and early spring, tagged saugers remained sedentary and moved short distances among pools in close proximity to each other. Longer movements by tagged saugers occurred from mid-spring to early summer, and were associated with both upstream and downstream movements to and from two river segments believed to be used for spawning. During early summer, most saugers returned to locations where they had been tagged the previous fall and had spent the winter. Our results provide evidence that preservation of the sauger fishery in the Wind River system will depend on maintaining fish passage throughout the portion of the watershed inhabited by saugers and preserving natural fluvial processes that maintain large and deep pools. ?? Copyright by the American Fisheries Society 2008.

  10. Hydrologic and hydraulic factors affecting passage of paddlefish through dams in the Upper Mississippi River

    USGS Publications Warehouse

    Zigler, S.J.; Dewey, M.R.; Knights, B.C.; Runstrom, A.L.; Steingraeber, M.T.

    2004-01-01

    Populations of paddlefish Polyodon spathula have been adversely affected by dams that can block their movements. Unlike high-head dams that preclude fish passage (unless they are equipped with fishways), the dams on the upper Mississippi River are typically low-head dams with bottom release gates that may allow fish passage under certain conditions. We evaluated the relation of dam head and river discharge to the passage of radio-tagged paddlefish through dams in the upper Mississippi River. Radio transmitters were surgically implanted into 71 paddlefish from Navigation Pools 5A and 8 of the upper Mississippi River and from two tributary rivers during fall 1994 through fall 1996. We tracked paddlefish through September 1997 and documented 53 passages through dams, 20 upstream and 33 downstream. Passages occurred mostly during spring (71%) but also occurred sporadically during summer and fall (29%). Spring passages varied among years in response to hydrologic conditions. We evaluated patterns in upstream and downstream passages with Cox proportional hazard regression models. Model results indicated that dam head height strongly affected the upstream passage of paddlefish but not the downstream passage. Several paddlefish, however, passed upstream through a dam during periods when the minimum head at the dam was substantial ( greater than or equal to 1m). In these cases, we hypothesize that paddlefish moved upstream through the lock chamber.

  11. A Retrospective Case Series of Surgical Implant Generation Network (SIGN) Placement at the Afghan National Police Hospital, Kabul, Afghanistan.

    PubMed

    Ertl, Christian W; Royal, David; Arzoiey, Humayoon Abdul; Shefa, Azizullah; Sultani, Salim; Mosafa, Mohammed Omar; Sadat, Safiullah; Zirkle, Lewis

    2016-01-01

    In Afghanistan, adequate and cost-effective medical care for even routine conditions is lacking; especially for complex injuries like long-bone fractures. The Surgical Implant Generation Network (SIGN) intramedullary nail is used for treatment of long-bone fractures from blunt injuries and does not require imaging. We are reporting for the first time results of the SIGN intramedullary nail at the Afghan National Police Hospital, a tertiary care facility in Kabul. 71 records from the SIGN Online Surgical Database were reviewed for gender, age, date of injury, implant date, patient's home of record, and type/ mechanism of injury. Mean age was 26.7 years, all but one being male; time from injury to implant ranged 1 to 401 days, with mean of 40.6 days. Long-bone fractures from motor vehicle accidents remained constant, and war injuries peaked in summer. Follow-up is limited because of security and financial burdens of travel. However, personal communication with Afghan National Police Hospital surgeons suggests that patients included in the current study have not experienced any adverse outcomes. While it remains to be seen if the SIGN Online Surgical Database will facilitate more comprehensive outcome studies, our results provide support for the efficacy of SIGN nails in treating long-bone fractures from war injuries. Reprint & Copyright © 2016 Association of Military Surgeons of the U.S.

  12. Intra-Arterial Hepatic Chemotherapy: A Comparison of Percutaneous Versus Surgical Implantation of Port-Catheters

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Deschamps, F., E-mail: frederic.deschamps@igr.fr; Elias, D., E-mail: elias@igr.fr; Goere, D., E-mail: goere@igr.fr

    2011-10-15

    Purpose: To compare retrospectively the safety and efficacy of percutaneous and surgical implantations of port-catheters for intra-arterial hepatic chemotherapy (IAHC). Materials and Methods: Between January 2004 and December 2008, 126 consecutive patients (mean age 58 years) suffering from liver colorectal metastases were referred for intra-arterial hepatic chemotherapy (IAHC). Port-catheters were percutaneously implanted (P) through femoral access with the patient under conscious sedation when no other surgery was planned or were surgically implanted (S) when laparotomy was performed for another purpose. We report the implantation success rate, primary functionality, functionality after revision, and complications of IAHC. Results: The success rates ofmore » implantation were 97% (n = 65 of 67) for P and 98% (n = 58 of 59) for S. One hundred eleven patients received IAHC in our institution (n = 56P and n = 55S). Primary functionality was the same for P and S (4.80 vs. 4.82 courses), but functionality after revision was significantly higher for P (9.18 vs. 5.95 courses, p = 0.004) than for S. Forty-five complications occurred during 516 courses for P and 28 complications occurred during 331 courses for S. The rates of discontinuation of IAHC linked to complications of the port-catheters were 21% (n = 12 of 56) for P and 34% (n = 19 of 55) for S. Conclusion: Overall, significantly better functionality and similar complication rates occurred after P versus S port-catheters.« less

  13. Diel habitat selection of largemouth bass following woody structure installation in Table Rock Lake, Missouri

    USGS Publications Warehouse

    Harris, J.M.; Paukert, Craig P.; Bush, S.C.; Allen, M.J.; Siepker, Michael

    2018-01-01

    Largemouth bass Micropterus salmoides (Lacepède) use of installed habitat structure was evaluated in a large Midwestern USA reservoir to determine whether or not these structures were used in similar proportion to natural habitats. Seventy largemouth bass (>380 mm total length) were surgically implanted with radio transmitters and a subset was relocated monthly during day and night for one year. The top habitat selection models (based on Akaike's information criterion) suggest largemouth bass select 2–4 m depths during night and 4–7 m during day, whereas littoral structure selection was similar across diel periods. Largemouth bass selected boat docks at twice the rate of other structures. Installed woody structure was selected at similar rates to naturally occurring complex woody structure, whereas both were selected at a higher rate than simple woody structure. The results suggest the addition of woody structure may concentrate largemouth bass and mitigate the loss of woody habitat in a large reservoir.

  14. AN IMPROVED PORTABLE SURGICAL TABLE FOR THE FIELD AND LABORATORY

    EPA Science Inventory

    I substantially modified a portable surgical table design by Courtois (1981) to increase its durability and utility. The new design incorporated durable plastic components, a nonskid neoprene surgery surface, and surgical tool bins. The system was used to implant fish and amphibi...

  15. XEN Gel Implant: a new surgical approach in glaucoma.

    PubMed

    Chaudhary, Ankita; Salinas, Lauriane; Guidotti, Jacopo; Mermoud, André; Mansouri, Kaweh

    2018-01-01

    Glaucoma is a leading cause of blindness worldwide. Intraocular pressure (IOP) lowering is the only effective treatment strategy. Traditional glaucoma surgeries are generally considered to be unpredictable and associated with a high rate of complications. This has led to the development of a novel XEN Gel Implant, a type of minimally invasive glaucoma surgery (MIGS), lowering the IOP without extensive surgical dissection. Areas covered: A literature search was undertaken on PubMed using the terms XEN glaucoma, gelatin microstent, and MIGS. All the articles and case reports on XEN Gel Implant and selected articles on MIGS were studied and reviewed. We have discussed the results of most studies on XEN Gel Implant related to its efficacy, safety and success. Expert commentary: The XEN Gel Implant effectively lowers IOP and medication use, with a favorable safety profile. Long-term data on its success and cost-effectiveness are lacking. The studies have shown it to be without any serious adverse events and to have good safety profile encouraging future research on this novel implant. There is a need to correctly identify selection criteria for patients, who would benefit the most from the XEN Gel Implant.

  16. In vivo biocompatibility of new nano-calcium-deficient hydroxyapatite/poly-amino acid complex biomaterials.

    PubMed

    Dai, Zhenyu; Li, Yue; Lu, Weizhong; Jiang, Dianming; Li, Hong; Yan, Yonggang; Lv, Guoyu; Yang, Aiping

    2015-01-01

    To evaluate the compatibility of novel nano-calcium-deficient hydroxyapatite/poly-amino acid (n-CDHA/PAA) complex biomaterials with muscle and bone tissue in an in vivo model. Thirty-two New Zealand white rabbits were used in this study. Biomaterials were surgically implanted into each rabbit in the back erector spinae and in tibia with induced defect. Polyethylene was implanted into rabbits in the control group and n-CDHA/PAA into those of the experimental group. Animals were examined at four different points in time: 2 weeks, 4 weeks, 12 weeks, and 24 weeks after surgery. They were euthanized after embolization. Back erector spinae muscles with the surgical implants were examined after hematoxylin and eosin (HE) staining at these points in time. Tibia bones with the surgical implants were examined by X-ray and scanning electron microscopy (SEM) at these points in time to evaluate the interface of the bone with the implanted biomaterials. Bone tissues were sectioned and subjected to HE, Masson, and toluidine blue staining. HE staining of back erector spinae muscles at 4 weeks, 12 weeks, and 24 weeks after implantation of either n-CDHA/PAA or polyethylene showed disappearance of inflammation and normal arrangement in the peripheral tissue of implant biomaterials; no abnormal staining was observed. At 2 weeks after implantation, X-ray imaging of bone tissue samples in both experimental and control groups showed that the peripheral tissues of the implanted biomaterials were continuous and lacked bone osteolysis, absorption, necrosis, or osteomyelitis. The connection between implanted biomaterials and bone tissue was tight. The results of HE, Masson, toluidine blue staining and SEM confirmed that the implanted biomaterials were closely connected to the bone defect and that no rejection had taken place. The n-CDHA/PAA biomaterials induced differentiation of a large number of chondrocytes. New bone trabecula began to form at 4 weeks after implanting n-CDHA/PAA biomaterials, and lamellar bone gradually formed at 12 weeks and 24 weeks after implantation. Routine blood and kidney function tests showed no significant changes at 2 weeks and 24 weeks after implantation of both biomaterials. n-CDHA/PAA composites showed good compatibility in in vivo model. In this study, n-CDHA/PAA were found to be safe, nontoxic, and biologically active in bone repair.

  17. In vivo biocompatibility of new nano-calcium-deficient hydroxyapatite/poly-amino acid complex biomaterials

    PubMed Central

    Dai, Zhenyu; Li, Yue; Lu, Weizhong; Jiang, Dianming; Li, Hong; Yan, Yonggang; Lv, Guoyu; Yang, Aiping

    2015-01-01

    Objective To evaluate the compatibility of novel nano-calcium-deficient hydroxyapatite/poly-amino acid (n-CDHA/PAA) complex biomaterials with muscle and bone tissue in an in vivo model. Methods Thirty-two New Zealand white rabbits were used in this study. Biomaterials were surgically implanted into each rabbit in the back erector spinae and in tibia with induced defect. Polyethylene was implanted into rabbits in the control group and n-CDHA/PAA into those of the experimental group. Animals were examined at four different points in time: 2 weeks, 4 weeks, 12 weeks, and 24 weeks after surgery. They were euthanized after embolization. Back erector spinae muscles with the surgical implants were examined after hematoxylin and eosin (HE) staining at these points in time. Tibia bones with the surgical implants were examined by X-ray and scanning electron microscopy (SEM) at these points in time to evaluate the interface of the bone with the implanted biomaterials. Bone tissues were sectioned and subjected to HE, Masson, and toluidine blue staining. Results HE staining of back erector spinae muscles at 4 weeks, 12 weeks, and 24 weeks after implantation of either n-CDHA/PAA or polyethylene showed disappearance of inflammation and normal arrangement in the peripheral tissue of implant biomaterials; no abnormal staining was observed. At 2 weeks after implantation, X-ray imaging of bone tissue samples in both experimental and control groups showed that the peripheral tissues of the implanted biomaterials were continuous and lacked bone osteolysis, absorption, necrosis, or osteomyelitis. The connection between implanted biomaterials and bone tissue was tight. The results of HE, Masson, toluidine blue staining and SEM confirmed that the implanted biomaterials were closely connected to the bone defect and that no rejection had taken place. The n-CDHA/PAA biomaterials induced differentiation of a large number of chondrocytes. New bone trabecula began to form at 4 weeks after implanting n-CDHA/PAA biomaterials, and lamellar bone gradually formed at 12 weeks and 24 weeks after implantation. Routine blood and kidney function tests showed no significant changes at 2 weeks and 24 weeks after implantation of both biomaterials. Conclusion n-CDHA/PAA composites showed good compatibility in in vivo model. In this study, n-CDHA/PAA were found to be safe, nontoxic, and biologically active in bone repair. PMID:26504382

  18. Successful non-surgical treatment of endocarditis caused by Staphylococcus haemolyticus following transcatheter aortic valve implantation (TAVI).

    PubMed

    Loverix, L; Timmermans, P; Benit, E

    2013-01-01

    We describe a case of a 79-year-old male patient with severe aortic stenosis who underwent transcatheter aortic valve implantation (TAVI) at our institution. He presented at the emergency department with dyspnea and fatigue 7 months after implantation. The diagnosis of early prosthetic valve endocarditis (PVE) caused by Staphylococcus haemolyticus was made by transesophageal echocardiography (TEE) and multiple positive blood cultures. Since our patient was considered inoperable due to a history of coronary artery bypass graft (CABG) surgery with patent bypasses, high peri-operative mortality including renal failure and a poor general prognosis, surgical removal of the valve was not an option. The patient was successfully treated with antibiotic therapy.

  19. Polymethyl-methacrylate implants in forehead and supraorbital arches reconstruction: retrospective study.

    PubMed

    Lustica, I; Velepic, M; Cvjetković, N; Bonifacić, M; Kirincić, N; Juretić, M; Braut, Z

    2001-01-01

    Frontobasal injuries and some other diseases of frontal sinuses sometimes require radical surgery with the obliteration of the sinus. A cosmetic correction of the forehead and supraorbital arches has to be performed after such a procedure. Nowadays, there is a wide choice of alloplastic materials on the market. We tried polymethyl methacrylate implants in correction of the exterior appearance of the forehead and supraorbital arches and followed the behaviour of the implants up to 25 years after surgery. The result was 18 (94.7%) successful implantations and one failure (5.3%) with a mild sagging of the borders of the implant. Polymethyl-methacrylate proved pliable for work and modelling, not invasive for the organism and stable. In conclusion, the cure of some frontobasal injuries and diseases with the first surgical step followed by cosmetic correction of the forehead and supraorbital arches (2nd surgical step) using this alloplastic material provides a safe, durable and aesthetically satisfactory solution for the patient.

  20. Surgical evaluation of candidates for cochlear implants

    NASA Technical Reports Server (NTRS)

    Black, F. O.; Lilly, D. J.; Fowler, L. P.; Stypulkowski, P. H.

    1987-01-01

    The customary presentation of surgical procedures to patients in the United States consists of discussions on alternative treatment methods, risks of the procedure(s) under consideration, and potential benefits for the patient. Because the contents of the normal speech signal have not been defined in a way that permits a surgeon systematically to provide alternative auditory signals to a deaf patient, the burden is placed on the surgeon to make an arbitrary selection of candidates and available devices for cochlear prosthetic implantation. In an attempt to obtain some information regarding the ability of a deaf patient to use electrical signals to detect and understand speech, the Good Samaritan Hospital and Neurological Sciences Institute cochlear implant team has routinely performed tympanotomies using local anesthesia and has positioned temporary electrodes onto the round windows of implant candidates. The purpose of this paper is to review our experience with this procedure and to provide some observations that may be useful in a comprehensive preoperative evaluation for totally deaf patients who are being considered for cochlear implantation.

  1. Use of an extensive radio receiver network to document Pacific lamprey (Lampetra tridentata) entrance efficiency at fishways in the Lower Columbia River, USA

    USGS Publications Warehouse

    Moser, M.L.; Matter, A.L.; Stuehrenberg, L.C.; Bjornn, T.C.

    2002-01-01

    We used an extensive network of more than 170 radio receiving stations to document fine-scale passage efficiency of adult anadromous Pacific lamprey at Bonneville and The Dalles Dams in the lower Columbia River in the northwestern U.S.A. Each spring from 1997 to 2000, we released 197-299 lamprey with surgically implanted radio transmitters. Unique transmitter codes and the date and time of reception at each antenna site were downloaded electronically, and initial processing was conducted to eliminate false positive signals. The resulting large Oracle database was analyzed using an Arc View-based coding protocol. Underwater antennas positioned outside the fishway entrances detected lamprey approaches, and antennas positioned immediately inside the entrances indicated successful entries. Entrance efficiency (the number of lamprey that successfully entered a fishway divided by the number that approached that fishway) was compared for different types of entrances (main entrances versus orifice entrances) and entrance locations (powerhouse versus spillway). Lamprey used orifice-type entrances less frequently than main entrances, and passage success was generally low (< 50%) at all entrances to fishways at Bonneville Dam (the lowest dam in the system). Lamprey activity at the entrances was highest at night, and entrance success was significantly higher at The Dalles Dam (the next dam upstream from Bonneville Dam) than at Bonneville Dam. In 1999 and 2000, construction modifications were made to Bonneville Dam spillway entrances, and water velocity at these entrances was reduced at night. Modifications to increase lamprey attachment at the entrances improved lamprey entrance efficiency, but entrance efficiency during reduced velocity tests was not significantly higher than during control conditions.

  2. Criteria for reducing predation by northern squawfish near juvenile salmonid bypass outfalls at Columbia River dams

    USGS Publications Warehouse

    Shively, Rip S.; Poe, Thomas P.; Sheer, Mindi B.; Peters, Rock

    1996-01-01

    Predation by northern squawfish (Ptychocheilus oregonensis) has been documented to be significant on emigrating juvenile salmonids near juvenile bypass outfalls at hydroelectric dams on the Columbia River. Criteria for siting juvenile fish bypass outfalls to reduce predation were developed using locational data from radio-tagged northern squawfish in The Dalles Dam trailrace, Columbia River. Radio transmitters were surgically implanted in 164 northern squawfish in 1993 and 1994, and their movements and distribution were monitored. Position estimates of northern squawfish were compared with data from a physical hydraulic model of the dam to estimate water velocities where northern squawfish were located. Eighty-two percent of northern squawfish position estimates were in water velocities ≤110 cm/s in 1993 and ≤90 cm/s in 1994. Fish locations were usually associated with water depths ≤10 m (84% in 1993 and 82% in 1994); 90% were within 110 m of the shore or dam structure in 1993, and 86% were within 80 m in 1994. In a related study at John Day Dam, Columbia River, where the juvenile bypass outfall is located 40 m from shore, water depth is 10 m and water velocities typically exceed 75 cm/s, only 13 of 1443 (0.9%) contacts on radio-tagged northern squawfish were located within 200 m of the bypass outfall. We recommend that new or modified juvenile bypass outfalls on the Columbia River be located in water velocities of ≥100 cm/s, ≥75 m from the shore or dam structure, and in water ≥10 m deep.

  3. Movement and habitat use by radio-tagged paddlefish in the upper Mississippi River and tributaries

    USGS Publications Warehouse

    Zigler, S.J.; Dewey, M.R.; Knights, B.C.; Runstrom, A.L.; Steingraeber, M.T.

    2003-01-01

    We used radio telemetry to evaluate the movement and habitat use of paddlefish Polyodon spathula in the upper Mississippi River and two tributary rivers. Radio transmitters were surgically implanted into 71 paddlefish in Navigation Pools 5A and 8 of the upper Mississippi River, the Chippewa River, and the Wisconsin River during fall 1994 through fall 1996. Radiotagged paddlefish were located through summer 1997. The range of paddlefish movement was typically low during all seasons except spring, but some paddlefish moved throughout the 420-km extent of the study area. Paddlefish tagged in the Chippewa River were closely linked with the upper Mississippi River, as substantial portions of the population inhabited the adjacent Navigation Pool 4 each spring; paddlefish in the Wisconsin River, however, rarely ventured out of that tributary. The use of aquatic area types by paddlefish varied among the study reaches. A cartographic model of paddlefish habitat suitability was developed for Navigation Pool 8 based on geographic information systems (GIS) coverages of bathymetry and current velocity. The value of paddlefish habitat in the cartographic model increased with depth and decreased with current velocity. For example, areas modeled as excellent corresponded to regions classified as having both deep water (greater than or equal to6.0 m) and negligible (<5 cm/s) current velocities. Our study suggests that aquatic area types are an inadequate basis for making sound management decisions regarding the critical habitats of paddlefish in complex riverine systems because such strata rely on gross geomorpological features rather than on the physicochemical variables that fish use to choose habitats. The development of systemic GIS coverages of such variables could improve the understanding of fish habitat selection and management in the upper Mississippi River.

  4. Recent developments in the remote radio control of insect flight.

    PubMed

    Sato, Hirotaka; Maharbiz, Michel M

    2010-01-01

    The continuing miniaturization of digital circuits and the development of low power radio systems coupled with continuing studies into the neurophysiology and dynamics of insect flight are enabling a new class of implantable interfaces capable of controlling insects in free flight for extended periods. We provide context for these developments, review the state-of-the-art and discuss future directions in this field.

  5. Recent Developments in the Remote Radio Control of Insect Flight

    PubMed Central

    Sato, Hirotaka; Maharbiz, Michel M.

    2010-01-01

    The continuing miniaturization of digital circuits and the development of low power radio systems coupled with continuing studies into the neurophysiology and dynamics of insect flight are enabling a new class of implantable interfaces capable of controlling insects in free flight for extended periods. We provide context for these developments, review the state-of-the-art and discuss future directions in this field. PMID:21629761

  6. Ferromagnetic movements of middle ear implants and stapes prostheses in a 3-T magnetic resonance field.

    PubMed

    Fritsch, Michael H; Gutt, Jason J

    2005-03-01

    A 3-T magnetic resonance field may cause motion or displacement of middle ear implants not seen in studies with 1.5-T magnets. Previous publications have described the safety limitations of some otologic implants in 1.5-T magnetic resonance fields. Several company-wide recalls of implants were issued. No studies to date have been reported for otologic implants within a 3-T magnetic resonance field, nor have there been comparisons with a 1.5-T field strength. Eighteen commonly used middle ear implants and prostheses were selected. In Part 1, the prostheses were placed in Petri dishes and exposed to a 3-T magnetic resonance field. In Part 2, the particular prostheses that showed movement in Part 1 were placed into their intended use positions within temporal bone laboratory specimens and exposed to a 3-T field. Both parts were repeated in a 1.5-T field. In Part 1, three prostheses moved dramatically from their start positions when exposed to the 3-T magnetic resonance field. In Part 2, the three particular prostheses that showed movement in Part 1 showed no gross displacement or movement from their start positions within the temporal bone laboratory specimens. No implants moved in the 1.5-T field in either Part 1 or Part 2. Certain stapes prostheses move dramatically in Petri dishes in 3-T fields. When placed into temporal bone laboratory specimens, the same prostheses show no signs of movement from the surgical site in a 3-T field, and it appears that the surgical position holds the implants firmly in place. Results of published 1.5-T field studies should not be used directly for safety recommendations in a 3-T magnetic resonance. Heat, voltage induction, and vibration during exposure to the magnetic resonance fields should be considered as additional possible safety issues. Preference should be given to platinum and titanium implants in manufacturing processes and surgical selection.

  7. Quasi-static strength and fractography analysis of two dental implants manufactured by direct metal laser sintering.

    PubMed

    Gehrke, Sergio Alexandre; Pérez-Díaz, Leticia; Dedavid, Berenice Anina

    2018-06-01

    New manufacturing methods was developed to improve the tissues integration with the titanium alloy pieces. The present in vitro study was to assess the resistance and fracture mode after applied a quasi-static compressive force on the two dental implants manufactured by direct metal laser sintering. Twenty dental implants manufactured by direct metal laser sintering, using titanium alloy (Ti-6Al-4V) granules in two designs (n = 10 per group): Conventional dental implant (group Imp1) two-piece implant design, where the surgical implant and prosthetic abutment are two separate components and, the one-piece implant (group Imp2), where the surgical implant and prosthetic abutment are one integral piece. All samples were subjected to quasi-static loading at a 30° angle to the implant axis in a universal testing machine. The mean fracture strengths were 1269.2 ± 128.8 N for the group Imp1 and, 1259.5 ± 115.1 N for the group Imp2, without statistical differences (P = .8722). In both groups, the fracture surface does not present crack between the compact core and the superficial (less dense and porous) part of the implants. Based on the measured resistance data for the two implant models manufactured by direct metal laser sintering tested in the present study, we can suggest that they have adequate capacity to withstand the masticatory loads. © 2018 Wiley Periodicals, Inc.

  8. Postrelease monitoring of radio-instrumented sea otters in Prince William Sound

    USGS Publications Warehouse

    Monnett, C.; Rotterman, L.M.; Stack, C.; Monson, Daniel H.; Bayha, Keith; Kormendy, Jennifer

    1990-01-01

    Sea otters (Enhydra lutris) that were captured in western Prince William Sound (PWS) or the Gulf of Alaska, treated, and held in captivity at the temporary rehabilitation centers established in response to the T/V Exxon Valdez oil spill were instrumented with radio transmitters, released into eastern PWS, and monitored by radiotelemetry. We undertook the present study to gain information for guiding the release of the remaining captive otters and evaluating the efficacy of sea otter rehabilitation after exposure to crude oil. Radio transmitters were attached to the flippers of seven sea otters released in May 1989 and monitored for periods of a few hours to more than 60 days. However, little was learned about the fate of these animals because the radio transmitters used proved unreliable. Forty-five additional sea otters from the rehabilitation centers were implanted with radio transmitters, released into northeastern PWS and monitored for 8 months. During the first 20 days after the first release of these implanted otters (n = 21), they were more mobile than wild-caught and released sea otters studied in PWS, from 1984 through 1990. All were alive and vigorous at the end of the 20-day period. Tracking of all 45 implanted sea otters during the 8-month period showed that the otters remained highly mobile. Many (46.6%) crossed into western PWS. However, by the end of the 8 months, 12 of the instrumented otters were dead and 9 were missing. One radio failed. These mortality and missing rates are much higher than those normally observed for adult sea otters in PWS. The death rate was highest in winter. These data suggest that, despite the tremendous amount of money and energy directed toward the treatment and care of these animals, the sea otters released from the centers were not completely rehabilitated, that is, not returned to a normal state. We recommend that future policies focus on preventing otters from becoming oiled, rather than attempting to treat them after oiling has occurred. This focus is especially recommended because of stress and disease risks associated with bringing wild animals into captivity.

  9. Hernia Surgical Mesh Implants

    MedlinePlus

    ... Surgical Clinics of North America; 83(5):1045-51, v-vi. 2 . http://www.facs.org/public_ ... FDA Contact FDA Browse by Product Area Product Areas back Food Drugs Medical Devices Radiation-Emitting Products ...

  10. The use of CO(2) laser in the treatment of peri-implantitis.

    PubMed

    Romanos, George; Ko, Hua-Hsin; Froum, Stuart; Tarnow, Dennis

    2009-06-01

    Different techniques have been used for the treatment of peri-implant defects. However, there are always questions about the issue of reosseointegration. The present paper explores the recent literature on the topic of peri-implantitis therapy, and presents a surgical protocol for implant surface decontamination using the CO(2) laser, grafting of the defect, and coverage with a membrane according to a clinical case. The results appear to be promising and may improve the long-term clinical outcomes of failing dental implants.

  11. [The treatment of patients with traumatic osteomyelitis of the mandible by using porous permeable titanium nickelide implants].

    PubMed

    Tazin, I D; Sysoliatin, P G; Panov, L A; Giunter, V E

    2000-01-01

    Use of titanium nickelide based porous permeable implants for repair of postosteomyelitis mandibular defects is discussed. Five patients with mandibular defects of different location and extent were operated on. Surgical methods are described. A clinical example of using a porous permeable implant is offered. The implant designed as a mandible was used for repair of an extensive mandibular defect. Good immediate and remote results of operations indicate good prospects of using such implants.

  12. Three-Dimensional Implant Positioning with a Piezosurgery Implant Site Preparation Technique and an Intraoral Surgical Navigation System: Case Report.

    PubMed

    Pellegrino, Gerardo; Taraschi, Valerio; Vercellotti, Tomaso; Ben-Nissan, Besim; Marchetti, Claudio

    This case report describes new implant site preparation techniques joining the benefits of using an intraoral navigation system to optimize three-dimensional implant site positioning in combination with an ultrasonic osteotomy. A report of five patients is presented, and the implant positions as planned in the navigation software with the postoperative scan image were compared. The preliminary results are useful, although further clinical studies with larger populations are needed to confirm these findings.

  13. Endometrial fluid associated with Essure implants placed before in vitro fertilization: Considerations for patient counseling and surgical management

    PubMed Central

    Walsh, David J; Jones, Christopher A; Wood, Samuel H

    2015-01-01

    Essure (Bayer) received approval from the U.S. Food and Drugs Administration as a permanent non-hormonal contraceptive implant in November 2002. While the use of Essure in the management of hydrosalpinx prior to in vitro fertilization (IVF) remains off-label, it has been used specifically for this purpose since at least 2007. Although most published reports on Essure placement before IVF have been reassuring, clinical experience remains limited, and no randomized studies have demonstrated the safety or efficacy of Essure in this context. In fact, no published guidelines deal with patient selection or counseling regarding the Essure procedure specifically in the context of IVF. Although Essure is an irreversible birth control option, some patients request the surgical removal of the implants for various reasons. While these patients could eventually undergo hysterectomy, at present no standardized technique exists for simple Essure removal with conservation of the uterus. This article emphasizes new aspects of the Essure procedure, as we describe the first known association between the placement of Essure implants and the subsequent development of fluid within the uterine cavity, which resolved after the surgical removal of both devices. PMID:26473113

  14. Five years follow-up of implant-prosthetic rehabilitation on a patient after mandibular ameloblastoma removal and ridge reconstruction by fibula graft and bone distraction

    PubMed Central

    Oteri, Giacomo; Ponte, Francesco Saverio De; Pisano, Michele; Cicciù, Marco

    2012-01-01

    This case report presents a combination of surgical and prosthetic solutions applied to a case of oral implant rehabilitation in post-oncologic reconstructed mandible. Bone resection due to surgical treatment of large mandibular neoplasm can cause long-span defects. Currently, mandibular fibula free flap graft is widely considered as a reliable technique for restoring this kind of defect. It restores the continuity of removed segment and re-establishes the contour of the lower jaw. However, the limited height of grafted fibula does not allow the insertion of regular length implants, therefore favouring vertical distraction osteogenesis as an important treatment choice. This report presents a patient affected by extensive mandibular ameloblastoma who underwent surgical reconstruction by fibula free flap because of partial mandibular resection. Guided distraction osteoneogenesis technique was applied to grafted bone, in order to obtain adequate bone height and to realize a prosthetically guided placement of 8 fixtures. After osseointegration, the patient was rehabilitated with a full arch, screw-retained prosthetic restoration. At five-years follow up, excellent integration of grafted tissue, steady levels of bone around the fixtures and healthy peri-implant tissues were reported. PMID:22623943

  15. Wireless implantable chip with integrated nitinol-based pump for radio-controlled local drug delivery.

    PubMed

    Fong, Jeffrey; Xiao, Zhiming; Takahata, Kenichi

    2015-02-21

    We demonstrate an active, implantable drug delivery device embedded with a microfluidic pump that is driven by a radio-controlled actuator for temporal drug delivery. The polyimide-packaged 10 × 10 × 2 mm(3) chip contains a micromachined pump chamber and check valves of Parylene C to force the release of the drug from a 76 μL reservoir by wirelessly activating the actuator using external radio-frequency (RF) electromagnetic fields. The rectangular-shaped spiral-coil actuator based on nitinol, a biocompatible shape-memory alloy, is developed to perform cantilever-like actuation for pumping operation. The nitinol-coil actuator itself forms a passive 185 MHz resonant circuit that serves as a self-heat source activated via RF power transfer to enable frequency-selective actuation and pumping. Experimental wireless operation of fabricated prototypes shows successful release of test agents from the devices placed in liquid and excited by radiating tuned RF fields with an output power of 1.1 W. These tests reveal a single release volume of 219 nL, suggesting a device's capacity of ~350 individual ejections of drug from its reservoir. The thermal behavior of the activated device is also reported in detail. This proof-of-concept prototype validates the effectiveness of wireless RF pumping for fully controlled, long-lasting drug delivery, a key step towards enabling patient-tailored, targeted local drug delivery through highly miniaturized implants.

  16. Practical application of electromyogram radiotelemetry: the suitability of applying laboratory-acquired calibration data to field data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Geist, David R.; Brown, Richard S.; Lepla, Ken

    One of the practical problems with quantifying the amount of energy used by fish implanted with electromyogram (EMG) radio transmitters is that the signals emitted by the transmitter provide only a relative index of activity unless they are calibrated to the swimming speed of the fish. Ideally calibration would be conducted for each fish before it is released, but this is often not possible and calibration curves derived from more than one fish are used to interpret EMG signals from individuals which have not been calibrated. We tested the validity of this approach by comparing EMG data within three groupsmore » of three wild juvenile white sturgeon Acipenser transmontanus implanted with the same EMG radio transmitter. We also tested an additional six fish which were implanted with separate EMG transmitters. Within each group, a single EMG radio transmitter usually did not produce similar results in different fish. Grouping EMG signals among fish produced less accurate results than having individual EMG-swim speed relationships for each fish. It is unknown whether these differences were a result of different swimming performances among individual fish or inconsistencies in the placement or function of the EMG transmitters. In either case, our results suggest that caution should be used when applying calibration curves from one group of fish to another group of uncalibrated fish.« less

  17. Fixation of revision implants is improved by a surgical technique to crack the sclerotic bone rim.

    PubMed

    Kold, Søren; Bechtold, Joan E; Mouzin, Olivier; Elmengaard, Brian; Chen, Xinqian; Søballe, Kjeld

    2005-03-01

    Revision joint replacement has poorer outcomes compared with primary joint replacement, and these poor outcomes have been associated with poorer fixation. We investigated a surgical technique done during the revision operation to improve access from the marrow space to the implant interface by locally cracking the sclerotic bone rim that forms during aseptic loosening. Sixteen implants were inserted bilaterally by distal femur articulation of the knee joint of eight dogs, using our controlled experimental model that replicates the revision setting (sclerotic bone rim, dense fibrous tissue, macrophages, elevated cytokines) by pistoning a loaded 6.0-mm implant 500 microm into the distal femur with particulate PE. At 8 weeks, one of two revision procedures was done. Both revision procedures included complete removal of the membrane, scraping, lavaging, and inserting a revision plasma-spray Ti implant. The crack revision procedure also used a splined tool to circumferentially locally perforate the sclerotic bone rim before insertion of an identical revision implant. Superior fixation was achieved with the cracking procedure in this experimental model. Revision implants inserted with the rim cracking procedure had a significantly higher pushout strength (fivefold median increase) and energy to failure (sixfold median increase), compared with the control revision procedure. Additional evaluation is needed of local perforation of sclerotic bone rim as a simple bone-sparing means to improve revision implant fixation and thereby increase revision implant longevity.

  18. Preservation of auditory brainstem response thresholds after cochleostomy and titanium microactuator implantation in the lateral wall of cat scala tympani.

    PubMed

    Lesinski, S George; Prewitt, Jessica; Bray, Victor; Aravamudhan, Radhika; Bermeo Blanco, Oscar A; Farmer-Fedor, Brenda L; Ward, Jonette A

    2014-04-01

    The safety of implanting a titanium microactuator into the lateral wall of cat scala tympani was assessed by comparing preoperative and postoperative auditory brainstem response (ABR) thresholds for 1 to 3 months. The safety of directly stimulating cochlear perilymph with an implantable hearing system requires maintaining preoperative hearing levels. This cat study is an essential step in the development of the next generation of fully implantable hearing devices for humans. Following GLP surgical standards, a 1-mm cochleostomy was drilled into the lateral wall of the scala tympani, and a nonfunctioning titanium anchor/microactuator assembly was inserted in 8 cats. The scala media was damaged in the 1 cat. ABR thresholds with click and 4- and 8-kHz stimuli were measured preoperatively and compared with postoperative thresholds at 1, 2, and 3 months. Nonimplanted ear thresholds were also measured to establish statistical significance for threshold shifts (>28.4 dB). Two audiologists independently interpreted thresholds. Postoperatively, 7 cats implanted in the scala tympani demonstrated no significant ABR threshold shift for click stimulus; one shifted ABR thresholds to 4- and 8-kHz stimuli. The eighth cat, with surgical damage to the scala media, maintained stable click threshold but had a significant shift to 4- and 8-kHz stimuli. This cat study provides no evidence of worsening hearing thresholds after fenestration of the scala tympani and insertion of a titanium anchor/microactuator, provided there is no surgical trauma to the scala media and the implanted device is securely anchored in the cochleostomy. These 2 issues have been resolved in the development of a fully implantable hearing system for humans. The long-term hearing stability (combined with histologic studies) reaffirm that the microactuator is well tolerated by the cat cochlea.

  19. Effects of different abutment material and surgical insertion torque on the marginal adaptation of an internal conical interface: an in vitro study.

    PubMed

    Farronato, Davide; Pieroni, Stefano; Mangano, Francesco Guido; Briguglio, Francesco; Re, Dino

    2014-10-01

    To evaluate the marginal adaptation at implant-abutment connection of an implant featuring a conical (45° taper) internal hexagonal abutment with a connection depth of 2.5mm, comparing the performance of two identical abutments of different material (titanium grade-4 and Co-Cr-alloy). Twenty implants (3.75 mm×15 mm) were connected to non-matching abutments (5.5 mm×10 mm) of two different materials (titanium grade-4: n=10; Co-Cr-alloy: n=10). The specimens were separately embedded in epoxylite resin, inside copper cylinders, and submerged without covering the most coronal portion (5 mm) of the fixture. Five specimens per group were stressed simulating a surgical 100 Ncm insertion torque, while the others had no torque simulation. All specimens were subjected to a non-axial static load (100 N) in a universal testing machine, under an angle of 30° with respect to the implant axis. Once 100 N load was reached, low shrinkage self-curing resin was injected inside the cylinders, and load was maintained until complete resin polymerization. Specimens were cut and analyzed with optical and scanning-electron-microscope (SEM) to evaluate the marginal adaptation at the implant-abutment connection. Statistical analysis was performed using one-way ANOVA (p=0.02). None of the 20 samples failed. The implant-abutment connection was able to guarantee a good optical seal; SEM analysis confirmed the absence of microgaps. Within the limits of this study (small sample size, limited time) the marginal adaptation of the implant-abutment connection was not affected by the abutment material nor by the application of surgical insertion torque. Copyright © 2014 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  20. Bacterial biofilms on implanted suture material are a cause of surgical site infection.

    PubMed

    Kathju, Sandeep; Nistico, Laura; Tower, Irene; Lasko, Leslie-Ann; Stoodley, Paul

    2014-10-01

    Surgical site infection (SSI) has been estimated to occur in up to 5% of all procedures, accounting for up to 0.5% of all hospital costs. Bacterial biofilms residing on implanted foreign bodies have been implicated as contributing or causative factors in a wide variety of infectious scenarios, but little consideration has been given to the potential for implanted, submerged suture material to act as a host for biofilm and thus serve as a nidus of infection. We report a series of 15 patients who underwent open Roux-en-Y gastric bypass (with musculofascial closure with permanent, multifilament sutures) who developed longstanding and refractory SSIs in the abdominal wall. Explanted suture material at subsequent exploration was examined for biofilm with confocal laser-scanning microscopy (CLSM) and fluorescence in situ hybridization (FISH). All 15 patients at re-exploration were found to have gross evidence of a "slimy" matrix or dense reactive granulation tissue localized to the implanted sutures. Confocal laser-scanning microscopy revealed abundant biofilm present on all sutures examined; FISH was able to identify the presence of specific pathogens in the biofilm. Complete removal of the foreign bodies (and attendant biofilms) resulted in all cases in cure of the SSI. Bacterial biofilms on implanted suture material can manifest as persistent surgical site infections that require complete removal of the underlying foreign body substrata for resolution.

  1. A novel surgical procedure for coronally repositioning of the buccal implant mucosa using acellular dermal matrix: a case report.

    PubMed

    Mareque-Bueno, Santiago

    2011-01-01

    This case report describes a surgical procedure for coronally advancing the peri-implant mucosa to treat a soft tissue dehiscence in a single-tooth implant-supported restoration in combination with an acellular dermal matrix graft. The patient was a 41-year-old systemically healthy, non-smoking female. Her chief complaint pertained to the unesthetic appearance of her right lateral upper incisor, caused by recession of the mucosal margin. On examination, a 3-mm recession could be observed. The periodontium was classified as thin. A 2-mm band of keratinized peri-implant mucosa was present. Keratinized gingiva was approximately 6 mm at adjacent areas. The surgical technique included a novel incision design to coronally position the flap over an acellular dermal matrix graft. Partial coverage of the recession was achieved. After a 6-month period, tissues appeared thicker than preoperatively, with no bleeding on probing and no probing depth >2 mm. The patient was satisfied with the overall treatment result. This case report shows the possibility of achieving partial soft tissue coverage over an implant-supported restoration with the combined use of an acellular dermal matrix and a coronally positioned flap. A novel technique is presented that allowed advancing the flap over the graft in a single-tooth restoration where enough keratinized tissue was present preoperatively.

  2. Positional and rotational stability of the toric phakic intraocular lens under high +Gz environments.

    PubMed

    Tan, Marcus C L; Nah, Gerard K M

    2012-02-01

    Phakic intraocular lens (PIOL) implantation is a surgical option for correction of refractive errors. PIOLs can be use to correct myopia, hyperopia, and astigmatism. It is a surgical option available to patients in addition to methods such as laser cornea refractive surgery, e.g., laser assisted in-situ keratomileusis (LASIK) and photo-refractive keratectomy (PRK). Visian implantable collamer lens (ICL) are posterior chamber lenses which are surgically positioned in a phakic eye in the sulcus between the iris diaphragm and the natural crystalline lens. This case report describes the stability of Visian toric ICL in a candidate with bilateral implants under high +Gz force exposure in a human centrifuge trainer. The subject was sequentially exposed to three incremental +Gz profiles of +5 Gz, +7 Gz, and +9 Gz. Pre- and post-+Gz exposure, ophthalmic examination revealed no ICL displacement, implant touch or induced cataract, or change in refractive error. The rotational stability of the toric implants was also demonstrated by identical subjective refractions in both eyes taken pre- and post-+Gz, exposure. A search of the literature did not reveal any published articles on intraocular stability of ICL in the +Gz environment. This case report suggests that ICL may be considered an alternative to laser refractive surgery for patients subjected to a high +G, environment such as military aviators.

  3. Electrospun nanofibrous scaffolds increase the efficacy of stem cell-mediated therapy of surgically resected glioblastoma

    PubMed Central

    Bagó, Juli R.; Pegna, Guillaume J.; Okolie, Onyi; Mohiti-Asli, Mahsa; Loboa, Elizabeth G.; Hingtgen, Shawn D.

    2017-01-01

    Engineered stem cell (SC)-based therapy holds enormous promise for treating the incurable brain cancer glioblastoma (GBM). Retaining the cytotoxic SCs in the surgical cavity after GBM resection is one of the greatest challenges to this approach. Here, we describe a biocompatible electrospun nanofibrous scaffold (bENS) implant capable of delivering and retaining tumor-homing cytotoxic stem cells that suppress recurrence of post-surgical GBM. As a new approach to GBM therapy, we created poly(l-lactic acid) (PLA) bENS bearing drug-releasing human mesenchymal stem cells (hMSCs). We discovered that bENS-based implant increased hMSC retention in the surgical cavity 5-fold and prolonged persistence 3-fold compared to standard direct injection using our mouse model of GBM surgical resection/recurrence. Time-lapse imaging showed cytotoxic hMSC/bENS treatment killed co-cultured human GBM cells, and allowed hMSCs to rapidly migrate off the scaffolds as they homed to GBMs. In vivo, bENS loaded with hMSCs releasing the anti-tumor protein TRAIL (bENSsTR) reduced the volume of established GBM xenografts 3-fold. Mimicking clinical GBM patient therapy, lining the post-operative GBM surgical cavity with bENSsTR implants inhibited the re-growth of residual GBM foci 2.3-fold and prolonged post-surgical median survival from 13.5 to 31 days in mice. These results suggest that nanofibrous-based SC therapies could be an innovative new approach to improve the outcomes of patients suffering from terminal brain cancer. PMID:27016620

  4. Potential of Wake-Up Radio-Based MAC Protocols for Implantable Body Sensor Networks (IBSN)—A Survey

    PubMed Central

    Karuppiah Ramachandran, Vignesh Raja; Ayele, Eyuel D.; Meratnia, Nirvana; Havinga, Paul J. M.

    2016-01-01

    With the advent of nano-technology, medical sensors and devices are becoming highly miniaturized. Consequently, the number of sensors and medical devices being implanted to accurately monitor and diagnose a disease is increasing. By measuring the symptoms and controlling a medical device as close as possible to the source, these implantable devices are able to save lives. A wireless link between medical sensors and implantable medical devices is essential in the case of closed-loop medical devices, in which symptoms of the diseases are monitored by sensors that are not placed in close proximity of the therapeutic device. Medium Access Control (MAC) is crucial to make it possible for several medical devices to communicate using a shared wireless medium in such a way that minimum delay, maximum throughput, and increased network life-time are guaranteed. To guarantee this Quality of Service (QoS), the MAC protocols control the main sources of limited resource wastage, namely the idle-listening, packet collisions, over-hearing, and packet loss. Traditional MAC protocols designed for body sensor networks are not directly applicable to Implantable Body Sensor Networks (IBSN) because of the dynamic nature of the radio channel within the human body and the strict QoS requirements of IBSN applications. Although numerous MAC protocols are available in the literature, the majority of them are designed for Body Sensor Network (BSN) and Wireless Sensor Network (WSN). To the best of our knowledge, there is so far no research paper that explores the impact of these MAC protocols specifically for IBSN. MAC protocols designed for implantable devices are still in their infancy and one of their most challenging objectives is to be ultra-low-power. One of the technological solutions to achieve this objective so is to integrate the concept of Wake-up radio (WuR) into the MAC design. In this survey, we present a taxonomy of MAC protocols based on their use of WuR technology and identify their bottlenecks to be used in IBSN applications. Furthermore, we present a number of open research challenges and requirements for designing an energy-efficient and reliable wireless communication protocol for IBSN. PMID:27916822

  5. Potential of Wake-Up Radio-Based MAC Protocols for Implantable Body Sensor Networks (IBSN)-A Survey.

    PubMed

    Karuppiah Ramachandran, Vignesh Raja; Ayele, Eyuel D; Meratnia, Nirvana; Havinga, Paul J M

    2016-11-29

    With the advent of nano-technology, medical sensors and devices are becoming highly miniaturized. Consequently, the number of sensors and medical devices being implanted to accurately monitor and diagnose a disease is increasing. By measuring the symptoms and controlling a medical device as close as possible to the source, these implantable devices are able to save lives. A wireless link between medical sensors and implantable medical devices is essential in the case of closed-loop medical devices, in which symptoms of the diseases are monitored by sensors that are not placed in close proximity of the therapeutic device. Medium Access Control (MAC) is crucial to make it possible for several medical devices to communicate using a shared wireless medium in such a way that minimum delay, maximum throughput, and increased network life-time are guaranteed. To guarantee this Quality of Service (QoS), the MAC protocols control the main sources of limited resource wastage, namely the idle-listening, packet collisions, over-hearing, and packet loss. Traditional MAC protocols designed for body sensor networks are not directly applicable to Implantable Body Sensor Networks (IBSN) because of the dynamic nature of the radio channel within the human body and the strict QoS requirements of IBSN applications. Although numerous MAC protocols are available in the literature, the majority of them are designed for Body Sensor Network (BSN) and Wireless Sensor Network (WSN). To the best of our knowledge, there is so far no research paper that explores the impact of these MAC protocols specifically for IBSN. MAC protocols designed for implantable devices are still in their infancy and one of their most challenging objectives is to be ultra-low-power. One of the technological solutions to achieve this objective so is to integrate the concept of Wake-up radio (WuR) into the MAC design. In this survey, we present a taxonomy of MAC protocols based on their use of WuR technology and identify their bottlenecks to be used in IBSN applications. Furthermore, we present a number of open research challenges and requirements for designing an energy-efficient and reliable wireless communication protocol for IBSN.

  6. Histological evaluations and inflammatory responses of different dental implant abutment materials: A human histology pilot study.

    PubMed

    Sampatanukul, Teeratida; Serichetaphongse, Pravej; Pimkhaokham, Atiphan

    2018-04-01

    Improvements of soft tissue to the abutment surface results in more stable peri-implant conditions, however, few human histological studies have compared soft tissue responses around different abutment materials. To describe the peri-implant tissue around 3 abutment materials; titanium, zirconia, and gold alloy, over an 8-week healing period. Fifteen edentulous sites were treated with implants. Eight weeks later, peri-implant tissue was harvested and processed using a nonseparation resin embedded technique. The tissue attachment characteristics were assessed at clinical stages using the gingival index (GI) score, surgical stage (surgical score), and histological stage (histological attachment percentage). Additionally, the inflammatory responses were evaluated using inflammatory extent and inflammatory cellularity grades. Nonparametrical statistics were used to describe the GI and surgical scores, and analytical statistics were used to analyze the histological attachment percentages as well as the inflammatory extent and cellularity grades amongst the 3 groups. There were no statistically significant differences among the groups for GI score (P = .071) and surgical score (P = .262). Titanium and zirconia exhibited nearly similar mean histological attachment percentages while gold alloy had a significantly lower percentage (P = .004). For the inflammatory extent and cellularity grades, the odds of being one grade higher for gold alloy abutment was 5.18 and 17.8 times that of titanium abutment, respectively. However, for the zirconia abutment, the odds were 0.87 and 7.5 times higher than the titanium group. The tissue around the gold alloy abutments resulted in worse attachment conditions compared with the titanium and zirconia abutments. Inflammation tended to be higher in the tissue around the gold alloy abutments than the titanium and zirconia abutments. © 2017 Wiley Periodicals, Inc.

  7. The rationale for the introduction of implant dentistry into the dental curriculum.

    PubMed

    Lang, N P; De Bruyn, H

    2009-02-01

    This paper provides arguments for the introduction of implant dentistry into the undergraduate curriculum. The survival of teeth is very high when disease is diagnosed and treated properly and maintenance is taken care of. Nevertheless, tooth replacements by fixed and removable prostheses are highly prevalent. It is expected that dentists will face a dramatically increased need to care for elderly patients and partially edentulous patients. Hence, the demand for implant reconstructions will be substantial and more appropriately trained and competent health professionals will be needed. Increasing demands of the patient regarding aesthetics and function will influence the demands for implant therapy. The improvement of oral function and subjective chewing comfort, the preservation of tooth structures or existing reconstructions and the replacement of missing, strategically important teeth are major indications for implant placement. From both a biological and an economical point of view, the single tooth replacement with an implant is the first choice in situations with no or minimally restored neighbouring teeth compared with conventional bridgework. Stability of full dentures represent a major problem especially for the mandible. It is well documented that placement of two implants supporting an overdenture substantially improve chewing capacity, increase quality of life and is a simple and cost-effective treatment thus rendering such treatment a 'standard of care' procedure. There is no doubt that dental students should learn to incorporate the indication of oral implants in their overall treatment planning. Therefore, they will have to understand the basic aspects of healing and tissue integration, basic biomechanical and material science principles as well as surgical and prosthetic techniques. They will have to be able to monitor continuously the peri-implant tissues, render appropriate supportive therapy and cope with biological and technical complications. While it is evident that the surgical procedure per se may require additional competence, the remainder of the aspects mentioned should be taught in the dental curriculum. This should include the attribution of responsibility for maintenance of implants and handling of biological and technical complications. Moreover, it is desirable to include the surgical technique for implant placement for 'straightforward' cases into the dental curriculum. The levels and limitations to which the various aspects of implant dentistry and related skills are to be taught are determined by the academic community. Obviously, ethical and legal aspects of implant dentistry should not be forgotten.

  8. The effect of platelet-rich fibrin on implant stability.

    PubMed

    Öncü, Elif; Alaaddinoğlu, E Emine

    2015-01-01

    Achieving accelerated implant osseointegration could make immediate or early loading of implants more predictable. Platelet-rich fibrin (PRF) is frequently used to accelerate soft and hard tissue healing. The activated platelets in PRF release growth factors, resulting in cellular proliferation, collagen synthesis, and osteoid production. The aim of this study was to compare the stability of dental implants inserted in a one-stage surgical protocol with or without PRF application. Twenty healthy patients with adequate alveolar bone and two or more adjacent missing teeth extracted at least 6 months previously were included in this study. A minimum of two tapered implants (Ankylos, Dentsply/Friadent) were placed in each patient. After surgical preparation of the implant sockets, PRF that had been prepared preoperatively was placed randomly into one of the sockets (PRF+). The acellular plasma portion of PRF was used to wet the implant placed into the PRF-coated socket. Resonance frequency measurements were made after implant placement and at 1 week and 1 month postoperatively. Mean implant stability quotients (ISQs) of the PRF+ implants was 69.3 ± 10.5, and mean ISQs for the PRF- implants was 64.5 ± 12.2 at the end of the first week. The mean ISQs at 4 weeks postoperatively were 77.1 ± 7.1 for the PRF+ group and 70.5 ± 7.7 for the PRF- group. In this study, PRF application increased implant stability during the early healing period, as evidenced by higher ISQ values. Simple application of this material seems to provide faster osseointegration.

  9. Influence of surgical and prosthetic techniques on marginal bone loss around titanium implants. Part I: immediate loading in fresh extraction sockets.

    PubMed

    Berberi, Antoine N; Tehini, Georges E; Noujeim, Ziad F; Khairallah, Alexandre A; Abousehlib, Moustafa N; Salameh, Ziad A

    2014-10-01

    Delayed placement of implant abutments has been associated with peri-implant marginal bone loss; however, long-term results obtained by modifying surgical and prosthetic techniques after implant placement are still lacking. This study aimed to evaluate the marginal bone loss around titanium implants placed in fresh extraction sockets using two loading protocols after a 5-year follow-up period. A total of 36 patients received 40 titanium implants (Astra Tech) intended for single-tooth replacement. Implants were immediately placed into fresh extraction sockets using either a one-stage (immediate loading by placing an interim prosthesis into functional occlusion) or a two-stage prosthetic loading protocol (insertion of abutments after 8 weeks of healing time). Marginal bone levels relative to the implant reference point were evaluated at four time intervals using intraoral radiographs: at time of implant placement, and 1, 3, and 5 years after implant placement. Measurements were obtained from mesial and distal surfaces of each implant (α = 0.05). One-stage immediate implant placement into fresh extraction sockets resulted in a significant reduction in marginal bone loss (p < 0.002) compared to the traditional two-stage technique. Whereas mesial surfaces remained stable for the 5-year observation period, significant marginal bone loss was observed on distal surfaces of implants after cementation of interim prostheses (p < 0.007) and after 12 months (p < 0.034). Within the limitations of this study, immediate loading of implants placed into fresh extraction sockets reduced marginal bone loss and did not compromise the success rate of the restorations. © 2014 by the American College of Prosthodontists.

  10. Shaped versus Round Implants in Breast Reconstruction: A Multi-Institutional Comparison of Surgical and Patient-Reported Outcomes.

    PubMed

    Khavanin, Nima; Clemens, Mark W; Pusic, Andrea L; Fine, Neil A; Hamill, Jennifer B; Kim, H Myra; Qi, Ji; Wilkins, Edwin G; Kim, John Y S

    2017-05-01

    Since the 2012 approval of shaped implants, their use in breast reconstruction has increased in the United States. However, large-scale comparisons of complications and patient-reported outcomes are lacking. The authors endeavored to compare surgical and patient-reported outcomes across implant types. The Mastectomy Reconstruction Outcomes Consortium database was queried for expander/implant reconstructions with at least 1-year postexchange follow-up (mean, 18.5 months). Outcomes of interest included postoperative complications, 1-year revisions, and patient-reported outcomes. Bivariate and mixed-effects regression analyses evaluated the effect of implant type on patient outcomes. Overall, 822 patients (73.5 percent) received round and 297 patients (26.5 percent) received shaped implants. Patients undergoing unilateral reconstructions with round implants underwent more contralateral symmetry procedures, including augmentations (round, 18.7 percent; shaped, 6.8 percent; p = 0.003) and reductions (round, 32.2 percent; shaped, 20.5 percent; p = 0.019). Shaped implants were associated with higher rates of infection (shaped, 6.1 percent; round, 2.3 percent; p = 0.002), that remained significant after multivariable adjustment. Other complication rates did not differ significantly between cohorts. Round and shaped implants experienced similar 2-year patient-reported outcome scores. This prospective, multicenter study is the largest evaluating outcomes of shaped versus round implants in breast reconstruction. Although recipients of round implants demonstrated lower infection rates compared with shaped implants, these patients were more likely to undergo contralateral symmetry procedures. Both implant types yielded comparable patient-reported outcome scores. With appropriate patient selection, both shaped and round implants can provide acceptable outcomes in breast reconstruction. Therapeutic, III.

  11. Scala vestibuli cochlear implantation in patients with partially ossified cochleas.

    PubMed

    Berrettini, Stefano; Forli, Francesca; Neri, Emanuele; Segnini, Giovanni; Franceschini, Stefano Sellari

    2002-11-01

    Partial cochlear obstruction is a relatively common finding in candidates for cochlear implants and frequently involves the inferior segment of the scala tympani in the basal turn of the cochlea. In such patients, the scala vestibuli is often patent and offers an alternative site for implantation. The current report describes two patients with such partial obstruction of the inferior segment of the basal cochlear turn, caused in one case by systemic vasculitis (Takayasu's disease) and in the other by obliterative otosclerosis. A scala vestibuli implantation allowed for complete insertion of the electrode array. No problems were encountered during the surgical procedures and the good post-operative hearing and communicative outcomes achieved were similar to those reported in patients without cochlear ossification. The importance of accurate pre-operative radiological study of the inner ear is underscored, to disclose the presence and define the features of the cochlear ossification and ultimately to properly plan the surgical approach.

  12. Transparency to Reduce Surgical Implant Waste.

    PubMed

    Pfefferle, Kiel J; Dilisio, Matthew F; Patti, Brianna; Fening, Stephen D; Junko, Jeffrey T

    2015-06-01

    Rising health care costs and emphasis on value have placed the onus of reducing healthcare costs on the surgeon. Financial data from 3,973 hip, knee, and shoulder arthroplasties performed at a physician owned orthopedic hospital was retrospectively reviewed over a two-year period. A wasted implant financial report was posted starting the second year of the study. Each surgeon's performance could be identified by his peers. After posting of the financial report, 1.11% of all hip and knee arthroplasty cases had a waste event compared to 1.50% during the control year. Shoulder arthroplasty waste events occurred twice as often than that observed in hip and knee arthroplasty during the study period. A decrease in waste events was observed but was not statistically significant (p = 0.30). Posting a non-blinded wasted implant data sheet was associated with a reduction in the number of wasted orthopedic surgical implants in this series, although the reduction was not statistically significant.

  13. [A condylar plate in distal femoral fractures].

    PubMed

    Hahn, U; Helling, H J; Rehm, K E

    2001-01-01

    Up to the seventies, the surgical treatment of supra- and bicondylar femoral fractures was difficult and was accompanied by a lot of complications. In most studies conservative treatment was recommended. In the last 30 years the clinical outcome after surgical treatment has improved. This was a result of the development of new implants and improved surgical techniques. Today, the primary surgical treatment is the therapy of choice. We reviewed from 1986 to 2000 105 distal femoral fractures which in 32 cases were treated with a condylar blade plate. The final results were rated using the system that was described by Neer. The averaged follow up time was 9 years. Low postoperative infection rates and in 75% excellent and satisfactory results combined with low cost are the state of art which has to be the reference for new methods and new implants in the future.

  14. Training considerations for the intracoelomic implantation of electronic tags in fish with a summary of common surgical errors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cooke, Steven J.; Wagner, Glenn N.; Brown, Richard S.

    2011-01-01

    Training is a fundamental part of all scientific and technical disciplines. This is particularly true for all types of surgeons. For surgical procedures, a number of skills are necessary to reduce mistakes. Trainees must learn an extensive yet standardized set of problem-solving and technical skills to handle challenges as they arise. There are currently no guidelines or consistent training methods for those intending to implant electronic tags in fish; this is surprising, considering documented cases of negative consequences of fish surgeries and information from studies having empirically tested fish surgical techniques. Learning how to do fish surgery once is insufficientmore » for ensuring the maintenance or improvement of surgical skill. Assessment of surgical skills is rarely incorporated into training, and is needed. Evaluation provides useful feedback that guides future learning, fosters habits of self-reflection and self-remediation, and promotes access to advanced training. Veterinary professionals should be involved in aspects of training to monitor basic surgical principles. We identified attributes related to knowledge, understanding, and skill that surgeons must demonstrate prior to performing fish surgery including a “hands-on” assessment using live fish. Included is a summary of common problems encountered by fish surgeons. We conclude by presenting core competencies that should be required as well as outlining a 3-day curriculum for training surgeons to conduct intracoelomic implantation of electronic tags. This curriculum could be offered through professional fisheries societies as professional development courses.« less

  15. Impact of 3D virtual planning on reconstruction of mandibular and maxillary surgical defects in head and neck oncology.

    PubMed

    Witjes, Max J H; Schepers, Rutger H; Kraeima, Joep

    2018-04-01

    This review describes the advances in 3D virtual planning for mandibular and maxillary reconstruction surgical defects with full prosthetic rehabilitation. The primary purpose is to provide an overview of various techniques that apply 3D technology safely in primary and secondary reconstructive cases of patients suffering from head and neck cancer. Methods have been developed to overcome the problem of control over the margin during surgery while the crucial decision with regard to resection margin and planning of osteotomies were predetermined by virtual planning. The unlimited possibilities of designing patient-specific implants can result in creative uniquely applied solutions for single cases but should be applied wisely with knowledge of biomechanical engineering principles. The high surgical accuracy of an executed 3D virtual plan provides tumor margin control during ablative surgery and the possibility of planned combined use of osseus free flaps and dental implants in the reconstruction in one surgical procedure. A thorough understanding of the effects of radiotherapy on the reconstruction, soft tissue management, and prosthetic rehabilitation is imperative in individual cases when deciding to use dental implants in patients who received radiotherapy.

  16. The zygomatic implant perforated (ZIP) flap: a new technique for combined surgical reconstruction and rapid fixed dental rehabilitation following low-level maxillectomy.

    PubMed

    Butterworth, C J; Rogers, S N

    2017-12-01

    This aim of this report is to describe the development and evolution of a new surgical technique for the immediate surgical reconstruction and rapid post-operative prosthodontic rehabilitation with a fixed dental prosthesis following low-level maxillectomy for malignant disease.The technique involves the use of a zygomatic oncology implant perforated micro-vascular soft tissue flap (ZIP flap) for the primary management of maxillary malignancy with surgical closure of the resultant maxillary defect and the installation of osseointegrated support for a zygomatic implant-supported maxillary fixed dental prosthesis.The use of this technique facilitates extremely rapid oral and dental rehabilitation within a few weeks of resective surgery, providing rapid return to function and restoring appearance following low-level maxillary resection, even in cases where radiotherapy is required as an adjuvant treatment post-operatively. The ZIP flap technique has been adopted as a standard procedure in the unit for the management of low-level maxillary malignancy, and this report provides a detailed step-by-step approach to treatment and discusses modifications developed over the treatment of an initial cohort of patients.

  17. Conservative surgical management of placenta accreta: a report of 3 cases.

    PubMed

    Pliskow, Steven; Dai, Xiaorong; Kohner, Andrew; Kapnick, Jason

    2009-10-01

    Placenta accreta is often diagnosed at the time of delivery and is a cause of postpartum hemorrhage, morbidity and mortality. The standard treatment for placenta accreta is hysterectomy to avoid acute blood loss and shock. A conservative surgical approach to the treatment of placenta accreta will allow immediate cure while preserving the patient's future fertility. A 39-year-old woman with placenta accreta diagnosed at the time of vaginal delivery was successfully treated with resection of the placental implantation site. A 33-year-old woman and a 35-year-old woman with placenta accreta/increta diagnosed at the time of cesarean section were successfully treated with resection of the placental implantation site. One patient has since conceived and given birth. Placenta accreta and placenta increta can be safely and successfully treated, in some well-selected cases, by resection of the placental implantation site and uterine repair. This conservative surgical management provides immediate therapy, reduces blood loss and preserves fertility.

  18. Rapid orthodontic treatment after the ridge-splitting technique--a combined surgical-orthodontic approach for implant site development: case report.

    PubMed

    Amato, Francesco; Mirabella, A Davide; Borlizzi, Diego

    2012-08-01

    This article presents a clinical case of bilateral partial edentulism in the posterior mandible with severe horizontal and moderate vertical bone atrophy. A new technique using rapid orthodontics after ridge splitting is presented. The split-crest technique was carried out using piezosurgical instruments in the first molar and second premolar areas to widen the bone crest and open a channel for tooth movement. Immediately after, orthodontic appliances were used to move the first premolars distally and the second molars mesially into the surgical site. The rationale was to facilitate and accelerate orthodontic movement of the teeth, which is otherwise difficult in a cortical knife-edged ridge. The bone defect was filled with the alveolar bone of the adjacent teeth that were moved into the surgically opened path. Adequate bone volume for implant placement was generated in the first premolar area. Implants were then inserted, and the patient was rehabilitated.

  19. Resonance Frequency Analysis for Osseointegration in Four Surgical Conditions of Dental Implants

    DTIC Science & Technology

    2001-10-25

    Osseointegration has been defined as “a process whereby a clinically asymptomatic rigid fixation of alloplastic materials is achieved and maintained...as the immediate implantation technique. In IIT model, the cervical third of dental implants are contacted to bone grafting materials, and apical ...Council, NSC- 89-2213-E-038-007. REFERENCES [1] Albrektsson T, Sennerby L. State of the art in oral implant. J. Clin. Periodontal . vol.18, pp. 474

  20. Sinus Floor Elevation with Modified Crestal Approach and Single Loaded Short Implants: A Case Report with 4 Years of Follow-Up

    PubMed Central

    Perelli, Michele; Abundo, Roberto; Corrente, Giuseppe; Saccone, Carlo

    2017-01-01

    Tooth extraction is usually followed by bone reduction. In the maxillary posterior region, this remodelling combined with sinus pneumatisation and periodontal defects may lead to a reduced basal bone height available for implant placement. Sinus floor elevation can be performed with different surgical techniques. Crestal approach has demonstrated to be effective, less invasive, and associated with a reduced morbidity. This article reports a modified sinus floor elevation by means of rotary, noncutting instruments, addition of xenograft, and 2 short-threaded implant placements. The aim of the study was to evaluate the implant's success and intrasinus radiographical bone gain after 4 years of functional loading. The premolar implant site presented a starting basal bone height of 6 mm, while the molar site was of 2 mm. In the first surgical step, sinus floor elevation was performed mesially and the implant was inserted, and distally only sinus floor elevation was performed. After 6 months, the mesial implant was uncovered and the second implant was inserted; 4 months later, the second fixture was uncovered, and both fixtures were loaded with single provisional screw-retained crowns and later with single screw-retained porcelain fused to metal crowns. Implants integrated successfully, and crestal bone remodelling did not exceed the smooth collar. Bone gain was 3 mm for the mesial implant and more than 5 mm for the distal one. PMID:29403665

  1. Sinus Floor Elevation with Modified Crestal Approach and Single Loaded Short Implants: A Case Report with 4 Years of Follow-Up.

    PubMed

    Perelli, Michele; Abundo, Roberto; Corrente, Giuseppe; Saccone, Carlo; Arduino, Paolo G

    2017-01-01

    Tooth extraction is usually followed by bone reduction. In the maxillary posterior region, this remodelling combined with sinus pneumatisation and periodontal defects may lead to a reduced basal bone height available for implant placement. Sinus floor elevation can be performed with different surgical techniques. Crestal approach has demonstrated to be effective, less invasive, and associated with a reduced morbidity. This article reports a modified sinus floor elevation by means of rotary, noncutting instruments, addition of xenograft, and 2 short-threaded implant placements. The aim of the study was to evaluate the implant's success and intrasinus radiographical bone gain after 4 years of functional loading. The premolar implant site presented a starting basal bone height of 6 mm, while the molar site was of 2 mm. In the first surgical step, sinus floor elevation was performed mesially and the implant was inserted, and distally only sinus floor elevation was performed. After 6 months, the mesial implant was uncovered and the second implant was inserted; 4 months later, the second fixture was uncovered, and both fixtures were loaded with single provisional screw-retained crowns and later with single screw-retained porcelain fused to metal crowns. Implants integrated successfully, and crestal bone remodelling did not exceed the smooth collar. Bone gain was 3 mm for the mesial implant and more than 5 mm for the distal one.

  2. Integration of 3D anatomical data obtained by CT imaging and 3D optical scanning for computer aided implant surgery

    PubMed Central

    2011-01-01

    Background A precise placement of dental implants is a crucial step to optimize both prosthetic aspects and functional constraints. In this context, the use of virtual guiding systems has been recognized as a fundamental tool to control the ideal implant position. In particular, complex periodontal surgeries can be performed using preoperative planning based on CT data. The critical point of the procedure relies on the lack of accuracy in transferring CT planning information to surgical field through custom-made stereo-lithographic surgical guides. Methods In this work, a novel methodology is proposed for monitoring loss of accuracy in transferring CT dental information into periodontal surgical field. The methodology is based on integrating 3D data of anatomical (impression and cast) and preoperative (radiographic template) models, obtained by both CT and optical scanning processes. Results A clinical case, relative to a fully edentulous jaw patient, has been used as test case to assess the accuracy of the various steps concurring in manufacturing surgical guides. In particular, a surgical guide has been designed to place implants in the bone structure of the patient. The analysis of the results has allowed the clinician to monitor all the errors, which have been occurring step by step manufacturing the physical templates. Conclusions The use of an optical scanner, which has a higher resolution and accuracy than CT scanning, has demonstrated to be a valid support to control the precision of the various physical models adopted and to point out possible error sources. A case study regarding a fully edentulous patient has confirmed the feasibility of the proposed methodology. PMID:21338504

  3. Determine the Influence of Time Held in “Knockdown” Anesthesia on Survival and Stress of Surgically Implanted Juvenile Salmonids

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Woodley, Christa M.; Wagner, Katie A.; Knox, Kasey M.

    2012-01-31

    The Juvenile Salmon Acoustic Telemetry System (JSATS) was developed for the U.S. Army Corp of Engineers Portland District (USACE) to address questions related to survival and performance measures of juvenile salmonids as they pass through the Federal Columbia River Power System (FCRPS). Researchers using JSATS acoustic transmitters (ATs) were tasked with standardizing the surgical implantation procedure to ensure that the stressors of handling and surgery on salmonids were consistent and less likely to cause effects of tagging in survival studies. Researchers questioned whether the exposure time in 'knockdown' anesthesia (or induction) to prepare fish for surgery could influence the survivalmore » of study fish (CBSPSC 2011). Currently, fish are held in knockdown anesthesia after they reach Stage 4 anesthesia until the completion of the surgical implantation of a transmitter, varies from 5 to 15 minutes for studies conducted in the Columbia Basin. The Columbia Basin Surgical Protocol Steering Committee (CBSPSC ) expressed concern that its currently recommended 10-minute maximum time limit during which fish are held in anesthetic - tricaine methanesulfonate (MS-222, 80 mg L-1 water) - could increase behavioral and physiological costs, and/or decrease survival of outmigrating juvenile salmonids. In addition, the variability in the time fish are held at Stage 4 could affect the data intended for direct comparison of fish within or among survival studies. Under the current recommended protocol, if fish exceed the 10-minute time limit, they are to be released without surgical implantation, thereby increasing the number of fish handled and endangered species 'take' at the bypass systems for FCRPS survival studies.« less

  4. A prospective study comparing endoscopic subcutaneous mastectomy plus immediate reconstruction with implants and breast conserving surgery for breast cancer.

    PubMed

    Fan, Lin-Jun; Jiang, Jun; Yang, Xin-Hua; Zhang, Yi; Li, Xing-Gang; Chen, Xian-Chun; Zhong, Ling

    2009-12-20

    Breast conserving surgery (BCS) has been the standard surgical procedure for the treatment of early breast cancer. Endoscopic subcutaneous mastectomy (ESM) plus immediate reconstruction with implants is an emerging procedure. The objective of this prospective study was to evaluate the clinical outcomes of these two surgical procedures in our clinical setting. From March 2004 to October 2007, 43 patients with breast cancer underwent ESM plus axillary lymph node dissection and immediate reconstruction with implants, while 54 patients underwent BCS. The clinical and pathological characteristics, surgical safety, and therapeutic effects were compared between the two groups. There were no significant differences in the age, clinical stage, histopathologic type of tumor, operative blood loss, postoperative drainage time, and postoperative complications between the two groups (P > 0.05). The postoperative complications were partial necrosis of the nipple and superficial skin flap in the ESM patients, and hydrops in the axilla and residual cavity in the BCS patients. There was no significant difference in the rate of satisfactory postoperative cosmetic outcomes between the ESM (88.4%, 38/43) and BCS (92.6%, 50/54) patients (P > 0.05). During follow-up of 6 months to 4 years, all patients treated with ESM were disease-free, but 3 patients who underwent BCS had metastasis or recurrence -one of these patients died of multiple organ metastasis. After considering the wide indications for use, high surgical safety, and favorable cosmetic outcomes, we conclude that ESM plus axillary lymph node dissection and immediate reconstruction with implants - the new surgery of choice for breast cancer - warrants serious consideration as the prospective next standard surgical procedure.

  5. Combined Orbital Fractures: Surgical Strategy of Sequential Repair

    PubMed Central

    Hur, Su Won; Kim, Sung Eun; Chung, Kyu Jin; Lee, Jun Ho; Kim, Tae Gon

    2015-01-01

    Background Reconstruction of combined orbital floor and medial wall fractures with a comminuted inferomedial strut (IMS) is challenging and requires careful practice. We present our surgical strategy and postoperative outcomes. Methods We divided 74 patients who underwent the reconstruction of the orbital floor and medial wall concomitantly into a comminuted IMS group (41 patients) and non-comminuted IMS group (33 patients). In the comminuted IMS group, we first reconstructed the floor stably and then the medial wall by using separate implant pieces. In the non-comminuted IMS group, we reconstructed the floor and the medial wall with a single large implant. Results In the follow-up of 6 to 65 months, most patients with diplopia improved in the first-week except one, who eventually improved at 1 year. All patients with an EOM limitation improved during the first month of follow-up. Enophthalmos (displacement, 2 mm) was observed in two patients. The orbit volume measured on the CT scans was statistically significantly restored in both groups. No complications related to the surgery were observed. Conclusions We recommend the reconstruction of orbit walls in the comminuted IMS group by using the following surgical strategy: usage of multiple pieces of rigid implants instead of one large implant, sequential repair first of the floor and then of the medial wall, and a focus on the reconstruction of key areas. Our strategy of step-by-step reconstruction has the benefits of easy repair, less surgical trauma, and minimal stress to the surgeon. PMID:26217562

  6. Early Clinical Results of a Novel Ab Interno Gel Stent for the Surgical Treatment of Open-angle Glaucoma.

    PubMed

    Sheybani, Arsham; Dick, H Burkhard; Ahmed, Iqbal I K

    2016-07-01

    To evaluate the intraocular pressure (IOP) lowering effect of the XEN140 microfistula gel stent implant for the surgical treatment of open-angle glaucoma. Forty-nine eyes of 49 patients with an IOP>18 mm Hg and ≤35 mm Hg were studied in a prospective nonrandomized multicenter cohort trial of the surgical implantation of the XEN140 implant in patients with open-angle glaucoma. Complete success was defined as a postoperative IOP≤18 mm Hg with ≥20% reduction in IOP at 12 months without any glaucoma medications. Failure was defined as vision loss of light perceptions vision or worse, need for additional glaucoma surgery, or <20% reduction of IOP from baseline. The average age was 64.3 (28.1 to 86.9) years old. Twenty-one eyes had prior failed trabeculectomy with mitomycin C surgery. IOP at 12 months decreased from a mean of 23.1 (±4.1) mm Hg to 14.7 (±3.7) mm Hg for a 36.4% reduction in IOP from baseline. The number of patients at 12 months who achieved an IOP≤18 mm Hg and ≥20% reduction in IOP was 40 (89%). The number of patients who achieved an IOP≤18 mm Hg and ≥20% reduction in IOP without antiglaucoma medications was 18 (40%). The XEN140 gel stent lowers IOP with few complications when implanted for the surgical treatment of open-angle glaucoma.

  7. Management of orbital fractures: challenges and solutions

    PubMed Central

    Boyette, Jennings R; Pemberton, John D; Bonilla-Velez, Juliana

    2015-01-01

    Many specialists encounter and treat orbital fractures. The management of these fractures is often challenging due to the impact that they can have on vision. Acute treatment involves a thorough clinical examination and management of concomitant ocular injuries. The clinical and radiographic findings for each individual patient must then be analyzed for the need for surgical intervention. Deformity and vision impairment can occur from these injuries, and while surgery is intended to prevent these problems, it can also create them. Therefore, surgical approach and implant selection should be carefully considered. Accurate anatomic reconstruction requires complete assessment of fracture margins and proper implant contouring and positioning. The implementation of new technologies for implant shaping and intraoperative assessment of reconstruction will hopefully lead to improved patient outcomes. PMID:26604678

  8. Prevalence, Etiology and Treatment of Peri-Implant Mucositis and Peri-Implantitis: A Survey of Periodontists in the United States.

    PubMed

    Papathanasiou, Evangelos; Finkelman, Matthew; Hanley, James; Parashis, Andreas O

    2016-05-01

    Currently, information available on the exact prevalence and standard therapeutic protocol of peri-implant diseases is insufficient. The aim of this survey was to investigate the perceived prevalence, etiology, and management of peri-implant mucositis and peri-implantitis by periodontists in the United States. A twenty-question survey was developed. Periodontists currently practicing in the United States were contacted by an e-mail that contained a link to access the survey. Two hundred eighty periodontists (79.3% males; 62.9% with >10 years in practice, 75.7% in private practice) completed the survey. Most (96.1%) of the participants were placing implants (58.3% for >10 years and 32.4% >150 implants/year). The majority reported that the prevalence of peri-implant mucositis and peri-implantitis in their practices is up to 25% but is higher in the general US population and that up to 10% of implants must be removed due to peri-implantitis. There was agreement among contributing etiologic factors such as: 1) plaque; 2) smoking; 3) adverse loading; 4) oral hygiene; 5) use of antimicrobial gel/mouthrinse; 6) non-surgical debridement; 7) use of systemic antibiotics; and 8) 3-month supportive care for treatment of peri-implantitis. Significant heterogeneity was recorded in relation to the instruments used for debridement, use and type of surgical treatment, and materials used for regeneration. Only 5.1% believed that treatment is very effective. This survey indicates that peri-implant diseases are a frequently encountered problem in periodontal practices and that the absence of a standard therapeutic protocol results in significant empirical use of therapeutic modalities and a moderately effective treatment outcome.

  9. Implant stability during initiation and resolution of experimental periimplantitis: an experimental study in the dog.

    PubMed

    Sennerby, Lars; Persson, Leif G; Berglundh, Tord; Wennerberg, Ann; Lindhe, Jan

    2005-01-01

    Histologic studies have demonstrated the possibility to reestablish direct bone-implant contacts after ligature-induced periimplantitis. The influence of the reosseointegration on the stability of implants is not known. The aim of the present investigation was to study bone tissue and associated implant stability alterations that occurred during induction and resolution of periimplantitis using resonance frequency analysis (RFA), radiography, and histology. Three implants with smooth (turned) or roughened (SLA) surfaces were placed in each side of the edentulous mandible of four dogs. Experimental periimplantitis was induced for 3 months. Five weeks later, the animals were treated with antibiotics and surgical therapy and were followed for another 6 months. Periapical radiographs and RFA were used to evaluate marginal bone levels and implant stability throughout the study period. After termination, the tissue-implant interface was evaluated by light microscopy in ground sections. There was a linear relationship between radiographic and RFA findings because continuous loss of marginal bone and a decrease in implant stability were observed for both implant surfaces during the periimplantitis period. Antibiotic treatment and surgical therapy resulted in some reosseointegration, which was more marked for the SLA surface. The resonance frequency values corresponded well to the histometric measurements because reosseointegration resulted in an increase in implant stability. The findings from the present study indicate a linear relationship between marginal bone level and resonance frequency value. It is suggested that the RFA technique is sensitive and may be used to detect even a minor change in the level of bone-implant contact.

  10. Implanted depleted uranium fragments cause soft tissue sarcomas in the muscles of rats.

    PubMed Central

    Hahn, Fletcher F; Guilmette, Raymond A; Hoover, Mark D

    2002-01-01

    In this study, we determined the carcinogenicity of depleted uranium (DU) metal fragments containing 0.75% titanium in muscle tissues of rats. The results have important implications for the medical management of Gulf War veterans who were wounded with DU fragments and who retain fragments in their soft tissues. We compared the tissue reactions in rats to the carcinogenicity of a tantalum metal (Ta), as a negative foreign-body control, and to a colloidal suspension of radioactive thorium dioxide ((232)Th), Thorotrast, as a positive radioactive control. DU was surgically implanted in the thigh muscles of male Wistar rats as four squares (2.5 x 2.5 x 1.5 mm or 5.0 x 5.0 x 1.5 mm) or four pellets (2.0 x 1.0 mm diameter) per rat. Ta was similarly implanted as four squares (5.0 x 5.0 x 1.1 mm) per rat. Thorotrast was injected at two sites in the thigh muscles of each rat. Control rats had only a surgical implantation procedure. Each treatment group included 50 rats. A connective tissue capsule formed around the metal implants, but not around the Thorotrast. Radiographs demonstrated corrosion of the DU implants shortly after implantation. At later times, rarifactions in the radiographic profiles correlated with proliferative tissue responses. After lifetime observation, the incidence of soft tissue sarcomas increased significantly around the 5.0 x 5.0 mm squares of DU and the positive control, Thorotrast. A slightly increased incidence occurred in rats implanted with the 2.5 x 2.5 mm DU squares and with 5.0 x 5.0 mm squares of Ta. No tumors were seen in rats with 2.0 x 1.0 mm diameter DU pellets or in the surgical controls. These results indicate that DU fragments of sufficient size cause localized proliferative reactions and soft tissue sarcomas that can be detected with radiography in the muscles of rats. PMID:11781165

  11. Maxillary reconstruction to enable implant insertion: a retrospective study of 181 patients

    PubMed Central

    Ferri, Joël; Dujoncquoy, Jean-Pascal; Carneiro, José Mario; Raoul, Gwénael

    2008-01-01

    Background The purpose of the present study was to evaluate different types of maxillary pre-prosthetic surgery using autogenous bone graft and suggest a guideline for maxillary reconstruction to place implant. Methods 181 patients (125 females and 56 males), age range from 16 to 76 years old, were operated at the Maxillo-Facial Service of the Lille's 2 Universitary Hospital Center (Chairman Pr Joël Ferri). Different techniques were used, but always with autogenous bone grafting. 21 patients underwent a Lefort 1 procedure, 139 underwent sinus graft with or without vestibular onlay graft and 21 underwent onlay graft. This surgical procedure was made to allow the insertion of 685 implants. Results The patients were evaluated by clinical and radiological assessment. In the cases of Lefort 1, the rate of successful osteointegration was higher when the implants were placed in the second part of a two stages procedure: 92%, against 81% for one stage. In cases of sinus lift procedure, the rate of implant success was 98%. The infection rate was 3.5%. There was no significant resorption and the type of prosthesis used was a denture retained by a bar or fixed bridge. In cases of onlay graft, the implant insertion success was 97% and there was no infection. The amount of resorption was more significant in the pre-maxilla than in the other areas and the type of prosthesis used was fixed dentures. Conclusion These observations demonstrate that: the aetiology of the bone defect indicate the type and number of the surgical procedures to re-established good jaws relationship and give the bone conditions to implant insertion successful. Clinical Relevance A guideline for surgical decision in the maxillary reconstruction for oral rehabilitation by implants may help to prevent failures of osseous resorption disorders and to foresee the investment of the bone in quality and necessary quantity. PMID:19087352

  12. [Postoperative Follow-Up of Glaucoma Drainage Devices].

    PubMed

    Dietlein, T S; Neugebauer, A; Fricke, J; Lappas, A; Rosentreter, A

    2016-05-01

    There is an increasing trend towards using glaucoma drainage implants. The postoperative management of such devices depends on their technical characteristics and specific complications. The Baerveldt glaucoma implant with its larger surface area has been shown to lower mean intraocular pressure more effectively than the Ahmed-FP7 implant. As a non-valve implant, however, it has been associated with a higher rate of severe complications, particularly ocular hypotension. Moreover, glaucoma implants may induce diplopia if they interfere with extraocular muscles. Topical treatment with antibiotics and steroids is necessary in cases of intraocular inflammation. In refractory cases, the tube may even have to be removed. Surgical reposition of the tube may be indicated when it is severely dislocated. Increased intraocular pressure is primarily treated by pressure-lowering medications during postoperative follow-up. If topical glaucoma medication is insufficient to control increases in intraocular pressure due to encapsulation, a second implant may be considered or the capsule surrounding the implant may be excised to reduce outflow resistance or additional cyclodestructive procedures can be performed. Chronic hypotension may be treated with tube ligation or occlusion. Severe corneal oedema may require lamellar keratoplasty. Conjunctival erosions with tube exposure or tube retractions also require surgical correction. Georg Thieme Verlag KG Stuttgart · New York.

  13. Various Techniques to Increase Keratinized Tissue for Implant Supported Overdentures: Retrospective Case Series

    PubMed Central

    Cayarga, Rodrigo; Suzuki, Takanori; Kaufman, Zev

    2015-01-01

    Purpose. The purpose of this retrospective case series is to describe and compare different surgical techniques that can be utilized to augment the keratinized soft tissue around implant-supported overdentures. Materials and Methods. The data set was extracted as deidentified information from the routine treatment of patients at the Ashman Department of Periodontology and Implant Dentistry at New York University College of Dentistry. Eight edentulous patients were selected to be included in this study. Patients were treated for lack of keratinized tissue prior to implant placement, during the second stage surgery, and after delivery of the final prosthesis. Results. All 8 patients in this study were wearing a complete maxillary and/or mandibular denture for at least a year before the time of the surgery. One of the following surgical techniques was utilized to increase the amount of keratinized tissue: apically positioned flap (APF), pedicle graft (PG), connective tissue graft (CTG), or free gingival graft (FGG). Conclusions. The amount of keratinized tissue should be taken into consideration when planning for implant-supported overdentures. The apical repositioning flap is an effective approach to increase the width of keratinized tissue prior to the implant placement. PMID:26124833

  14. [Analysis of the incidence and causes of repeated surgical interventions in patients with early complications electrotherapy - 1 center experience from the period 2012-2015].

    PubMed

    Piątek, Łukasz; Polewczyk, Anna; Kurzawski, Jacek; Zachura, Małgorzata; Kaczmarczyk, Małgorzata; Janion, Marianna

    Due to increasing number of patients treated by cardiac implantable electronic devices we observe increasing number of complications after these procedures We analysed causes of early surgical revision of implantable devices connected with 1673 procedures of implantation (871 procedures) or exchange (802 procedures) of pacing systems (PM), cardioverter-difibrillators (ICD) and resynchronisation systems (CRT) in one local centre of electrotherapy in years 2012 to 2015. We characterised risk factors and its influence on encountered complications. In analysed period 72 reinterventions after implantations or exchanges of PM/ICD/CRT were performed. Main causes of early complications were: lead malfunction (2.5%), including the dislodgement of the leads in 1.9%, pocket hematoma (1.4%) and other abnormalities of the pocket (0.4 %), including pocket infections in 0.2%. The most important risk factors of early complications were often implantations of the leads with passive fixation and anticoagulation therapy in perioperative period. The knowledge of the early complications after implantations and exchanges of PM/ICD/CRT should improve the safety of procedures through more often used of the leads with active fixation and properly preparation of the patients requering the antithrombic therapy.

  15. The socially constructed breast: breast implants and the medical construction of need.

    PubMed Central

    Jacobson, N

    1998-01-01

    When silicone gel breast implants became the subject of a public health controversy in the early 1990s, the most pressing concern was safety. This paper looks at another, less publicized issue: the need for implants. Using a symbolic interactionist approach, the author explores the social construction of the need for implants by tracing the history of the 3 surgical procedures for which implants were used. Stakeholders in this history constructed need as legitimized individual desire, the form of which shifted with changes in the technological and social context. PMID:9702166

  16. The Relationship of Bacterial Biofilms and Capsular Contracture in Breast Implants

    PubMed Central

    Ajdic, Dragana; Zoghbi, Yasmina; Gerth, David; Panthaki, Zubin J.; Thaller, Seth

    2016-01-01

    Capsular contracture is a common sequelae of implant-based breast augmentation. Despite its prevalence, the etiology of capsular contracture remains controversial. Numerous studies have identified microbial biofilms on various implantable materials, including breast implants. Furthermore, biofilms have been implicated in subclinical infections associated with other surgical implants. In this review, we discuss microbial biofilms as a potential etiology of capsular contracture. The review also outlines the key diagnostic modalities available to identify the possible infectious agents found in biofilm, as well as available preventative and treatment measures. PMID:26843099

  17. Prosthetic Consideration in Implant-supported Prosthesis: A Review of Literature

    PubMed Central

    Gowd, Manga Snigdha; Shankar, Thatapudi; Ranjan, Rajeev; Singh, Arpita

    2017-01-01

    Modern dentistry has changed tremendously with implant therapy. For the successful implant therapy, making a proper treatment plan considering both surgical and prosthetic part in mind is the key of success. Often practitioners tend to create a treatment plan overlooking the basic principles of prosthetic part. This present review has discussed various prosthetic consideration of implant-supported prosthesis. A step-by-step detailed prosthetic option with their indications has been discussed to help all dental implant practitioners in making of an optimal treatment plan for each case. PMID:28713760

  18. Development of a surgical navigation system based on 3D Slicer for intraoperative implant placement surgery

    PubMed Central

    Chen, Xiaojun; Xu, Lu; Wang, Huixiang; Wang, Fang; Wang, Qiugen; Kikinis, Ron

    2017-01-01

    Implant placement has been widely used in various kinds of surgery. However, accurate intraoperative drilling performance is essential to avoid injury to adjacent structures. Although some commercially-available surgical navigation systems have been approved for clinical applications, these systems are expensive and the source code is not available to researchers. 3D Slicer is a free, open source software platform for the research community of computer-aided surgery. In this study, a loadable module based on Slicer has been developed and validated to support surgical navigation. This research module allows reliable calibration of the surgical drill, point-based registration and surface matching registration, so that the position and orientation of the surgical drill can be tracked and displayed on the computer screen in real time, aiming at reducing risks. In accuracy verification experiments, the mean target registration error (TRE) for point-based and surface-based registration were 0.31±0.06mm and 1.01±0.06mm respectively, which should meet clinical requirements. Both phantom and cadaver experiments demonstrated the feasibility of our surgical navigation software module. PMID:28109564

  19. Conservative surgical and microsurgical techniques for the management of dental implants that impinge on the inferior alveolar nerve.

    PubMed

    Gennaro, Paolo; Chisci, Glauco; Gabriele, Guido; Iannetti, Giorgio

    2014-07-01

    Loss of sensation in the lip after insertion of an implant is annoying. The aim of this paper was to describe two techniques for management of osseointegrated dental implants that impinge on the mandibular nerve, the purpose of which is to improve sensation without unscrewing the dental implant. Copyright © 2014 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  20. Air powder abrasive treatment as an implant surface cleaning method: a literature review.

    PubMed

    Tastepe, Ceylin S; van Waas, Rien; Liu, Yuelian; Wismeijer, Daniel

    2012-01-01

    To evaluate the air powder abrasive treatment as an implant surface cleaning method for peri-implantitis based on the existing literature. A PubMed search was conducted to find articles that reported on air powder abrasive treatment as an implant surface cleaning method for peri-implantitis. The studies evaluated cleaning efficiency and surface change as a result of the method. Furthermore, cell response toward the air powder abrasive-treated discs, reosseointegration, and clinical outcome after treatment is also reported. The PubMed search resulted in 27 articles meeting the inclusion criteria. In vitro cleaning efficiency of the method is reported to be high. The method resulted in minor surface changes on titanium specimens. Although the air powder abrasive-treated specimens showed sufficient levels of cell attachment and cell viability, the cell response decreased compared with sterile discs. Considerable reosseointegration between 39% and 46% and improved clinical parameters were reported after treatment when applied in combination with surgical treatment. The results of the treatment are influenced by the powder type used, the application time, and whether powder was applied surgically or nonsurgically. The in vivo data on air powder abrasive treatment as an implant surface cleaning method is not sufficient to draw definitive conclusions. However, in vitro results allow the clinician to consider the method as a promising option for implant surface cleaning in peri-implantitis treatment.

  1. Soft tissue remodeling technique as a non-invasive alternative to second implant surgery.

    PubMed

    Vela, Xavier; Méndez, Víctor; Rodríguez, Xavier; Segalà, Maribel; Gil, Jaime A

    2012-01-01

    It is currently accepted that success in implant-supported restorations is based not only on osseointegration, but also on achieving the esthetic outcome of natural teeth and healthy soft tissues. The socalled "pink esthetic" has become the main challenge with implant-supported rehabilitations in the anterior area. This is especially difficult in the cases with two adjacent implants. Two components affect the final periimplant gingiva: a correct bone support, and a sufficient quantity and quality of soft tissues. Several papers have emphasized the need to regenerate and preserve the bone after extractions, or after the exposure of the implants to the oral environment. The classical implantation protocol entails entering the working area several times and always involves the surgical manipulation of peri-implant tissues. Careful surgical handling of the soft tissues when exposing the implants and placing the healing abutments (second surgery) helps the clinician to obtain the best possible results, but even so there is a loss of volume of the tissues as they become weaker and more rigid after each procedure. The present study proposes a new protocol that includes the connective tissue graft placement and the soft tissues remodeling technique, which is based on the use of the ovoid pontics. This technique may help to minimize the logical scar reaction after the second surgery and to improve the final emergence profile.

  2. Mechanical and chemical implant decontamination in surgical peri-implantitis treatment: preclinical "in vivo" study.

    PubMed

    Carral, Cristina; Muñoz, Fernando; Permuy, María; Liñares, Antonio; Dard, Michel; Blanco, Juan

    2016-08-01

    The aim of the present study was to evaluate the effect of a titanium brush and chemical agents following surgical treatment of experimental peri-implantitis. Six implants were installed in the mandible of eight beagle dogs (unit of analysis) 3 months after tooth extraction. Experimental peri-implantitis was induced 3 months later. The defects were randomly allocated in three treatment groups: (a) TiBrush(™)  + sodium hypochlorite + chlorhexidine (TBH), (b) TiBrush(™)  + chlorhexidine (TB), (c) an ultrasonic device + chlorhexidine (US). The distal implant in each hemimandible was used as control, and no treatment was done. Clinical and histological measurements were performed after 3 months of healing. All treatment procedures resulted in statistically significant improvements of all clinical parameters. Histomorphometrical analysis revealed no statistically significant differences between treatment groups in terms of woven bone height (primary outcome). However, there were differences between test and control groups in terms of inflammation, bone defect depth and bone refill without differences between TBH and TB groups. Resolution of peri-implantitis after access surgery and decontamination of peri-implant surfaces with TiBrush(™) with or without sodium hypochlorite is possible. However, the concomitant use of sodium hypochlorite has minor effect on treatment outcomes. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  3. The vagal nerve stimulation outcome, and laryngeal effect: Otolaryngologists roles and perspective.

    PubMed

    Al Omari, Ahmad I; Alzoubi, Firas Q; Alsalem, Mohammad M; Aburahma, Samah K; Mardini, Diala T; Castellanos, Paul F

    Epilepsy is one of the most common neurologic disorders. Vagus nerve stimulation (VNS), first investigated in 1938 and subsequently studied as a potential therapy for epilepsy. The FDA approved the use of VNS in 1997 as an adjunctive non-pharmacologic symptomatic treatment option for refractory epilepsy for adults and adolescents over 12years. VNS can cause laryngeal and voice side effects that can be managed by otolaryngologists safely and effectively. This study is to review the outcomes of vagal nerve stimulator (VNS) implantation in terms of the surgical procedures, complications, seizure frequency, and the clinical effect on larynx and vocal folds motion. Series of thirty consecutive patients who had VNS implantation between 2007 and 2014 were recruited. Seizure-frequency outcome, surgical complications and device adverse effects of VNS were retrospectively reviewed. Additional evaluation included use of the Voice Handicap Index and Maximum Phonation Time (MPT) were conducted before and after the implantation. Videolaryngoscopy was used to evaluate the vocal fold mobility before and after the VNS implantation. Seizure frequency reduction over a minimum of 2years of follow up demonstrated: 100% in seizure frequency reduction in 1 patient, drastic reduction in seizure frequency (70-90%) in 9 patients, a good reduction in terms of seizure frequency (50%) in 8 patients, a 30% reduction in 5 patients, no response in 6 patients, and 1 patient had increased frequency. The most commonly reported adverse effects after VNS activation were coughing and voice changes with pitch breaks, as well as mild intermittent shortness of breath in 33% of patients. For those patients secondary supraglottic muscle tension and hyper function with reduced left vocal fold mobility were noticed on videolaryngoscopy, though none had aspiration problems. Surgical complications included a wound dehiscence in one patient (3%) which was surgically managed, minor intra-operative bleeding 3%; a superficial wound infection in one patient (3%) which was treated conservatively, none of the complications necessitated VNS removal. VNS appears to be an effective non-pharmacologic adjuvant therapy in patients with medically refractory seizures. With the favorable adverse-effect profile previously described, VNS is generally well tolerated and of a great benefit to such patients. Laryngeal side effects, of which hoarseness being of the greatest repetition, are the most common after the VNS implantation. VNS can affect the voice and reduced vocal cord motion on the implantation side with secondary supraglottic muscle tension. Otolaryngologists are not only capable of performing VNS implantation, but can also manage surgical complications, assess laryngeal side effects and treat them as needed. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. A touch probe method of operating an implantable RFID tag for orthopedic implant identification.

    PubMed

    Liu, Xiaoyu; Berger, J Lee; Ogirala, Ajay; Mickle, Marlin H

    2013-06-01

    The major problem in operating an implantable radio-frequency identification (RFID) tag embedded on an orthopedic implant is low efficiency because of metallic interference. To improve the efficiency, this paper proposes a method of operating an implantable passive RFID tag using a touch probe at 13.56 MHz. This technology relies on the electric field interaction between two pairs of electrodes, one being a part of the touch probe placed on the surface of tissue and the other being a part of the tag installed under the tissue. Compared with using a conventional RFID antenna such as a loop antenna, this method has a better performance in the near field operation range to reduce interference with the orthopedic implant. Properly matching the touch probe and the tag to the tissue and the implant reduces signal attenuation and increases the overall system efficiency. The experiments have shown that this method has a great performance in the near field transcutaneous operation and can be used for orthopedic implant identification.

  5. Surface Modification of Direct-Current and Radio-Frequency Oxygen Plasma Treatments Enhance Cell Biocompatibility

    PubMed Central

    Wang, Rex C.-C.; Liu, Cheng; Yang, Chyun-Yu

    2017-01-01

    The sand-blasting and acid etching (SLA) method can fabricate a rough topography for mechanical fixation and long-term stability of titanium implant, but can not achieve early bone healing. This study used two kinds of plasma treatments (Direct-Current and Radio-Frequency plasma) to modify the SLA-treated surface. The modification of plasma treatments creates respective power range and different content functional OH groups. The results show that the plasma treatments do not change the micron scale topography, and plasma-treated specimens presented super hydrophilicity. The X-ray photoelectron spectroscopy (XPS)-examined result showed that the functional OH content of the RF plasma-treated group was higher than the control (SLA) and DC treatment groups. The biological responses (protein adsorption, cell attachment, cell proliferation, and differentiation) promoted after plasma treatments, and the cell responses, have correlated to the total content of amphoteric OH groups. The experimental results indicated that plasma treatments can create functional OH groups on SLA-treated specimens, and the RF plasma-treated SLA implant thus has potential for achievement of bone healing in early stage of implantation. PMID:29068417

  6. A Discussion of Commercially Available Intra-ocular Telescopic Implants for Patients with Age-Related Macular Degeneration.

    PubMed

    Dunbar, Hannah M P; Dhawahir-Scala, Felipe E

    2018-06-01

    Age-related macular degeneration (AMD) is the leading cause of visual impairment in the western world, causing significant reduction in quality of life. Despite treatment advances, the burden of visual impairment caused by AMD continues to rise. In addition to traditional low vision rehabilitation and support, optical and electronic aids, and strategies to enhance the use of peripheral vision, implantable telescopic devices have been indicated as a surgical means of enhancing vision. Here we examine the literature on commercially available telescopic devices discussing their design, mode of action, surgical procedure and published outcomes on visual acuity, quality of life, surgical complication rates and cost effectiveness data where available.Funding Article processing charges were funded by VisionCare Inc.

  7. Osteochondral Autograft from the Ipsilateral Femoral Head by Surgical Dislocation for Treatment of Femoral Head Fracture Dislocation: A Case Report.

    PubMed

    Won, Yougun; Lee, Gi Soo; Kim, Sang Bum; Kim, Sun Joong; Yang, Kyu Hyun

    2016-11-01

    As anatomical reduction of the articular surface of femoral head fractures and restoration of damaged cartilage are essential for good long-term results, many treatment options have been suggested, including fixation of the fracture using various surgical exposures and implants, as well as arthroscopic irrigation and debridement, bone marrow stimulating techniques, osteochondral allograft, autograft, and autogenous chondrocyte implantation. We report a case of osteochondral autograft harvested from its own femoral articular surface through surgical hip dislocation. The osteochondral graft was harvested from the inferior non-weight-bearing articular surface and grafted to the osteochondral defect. One year later, the clinical and radiological results were good, without the collapse of the femoral head or arthritic change. This procedure introduced in our case is considered convenient and able to lessen surgical time without morbidity of the donor site associated with the harvest.

  8. Carpal valgus in llamas and alpacas: Retrospective evaluation of patient characteristics, radiographic features and outcomes following surgical treatment

    PubMed Central

    Hunter, Barbara; Duesterdieck-Zellmer, Katja F.; Huber, Michael J.; Parker, Jill E.; Semevolos, Stacy A.

    2014-01-01

    This study evaluated outcomes of surgical treatment for carpal valgus in New World camelids and correlated successful outcome (absence of carpal valgus determined by a veterinarian) with patient characteristics and radiographic features. Univariable and multivariable analyses of retrospective case data in 19 camelids (33 limbs) treated for carpal valgus between 1987 and 2010 revealed that procedures incorporating a distal radial transphyseal bridge were more likely (P = 0.03) to result in success after a single surgical procedure. A greater degree of angulation (> 19°, P = 0.02) and younger age at surgery (< 4 months, P = 0.03) were associated with unsuccessful outcome. Overall, 74% of limbs straightened, 15% overcorrected, and 11% had persistent valgus following surgical intervention. To straighten, 22% of limbs required multiple procedures, not including implant removal. According to owners, valgus returned following implant removal in 4 limbs that had straightened after surgery. PMID:25477542

  9. Holding of juvenile salmonids for surgical implantation of electronic tags: a review and recommendations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oldenburg, Eric W.; Colotelo, Alison HA; Brown, Richard S.

    Many telemetry based studies require that fish be sampled from the wild and then held for some amount of time both prior to and after the implantation of a transmitter. However, the effects of such holding (or the lack thereof) are often overlooked. Pre-surgical holding often occurs to facilitate logistical needs of research projects and as an attempt to minimize negative physiological effects due to capture and handling stress. Further, post-surgical holding time and conditions greatly influence the physiological state of fish prior to being returned to the wild. This paper reviews pertinent studies pertaining to the effects of surgicalmore » holding on the behavior, physiology, and survival of fishes, with particular emphasis on juvenile salmonids. The effects of individual aspects of surgical holding such as stressors, time, holding conditions and water quality are also examined. Recommendations regarding certain aspects of surgical holding (e.g., holding duration) are offered with a goal of reducing bias related to the surgical process. Pre- and post-surgical holding times of 18–36 h are suggested as a general guideline for juvenile salmonids.« less

  10. [A clinical investigation of new patients who had already received treatment with dental implants at other clinics in seventeen years].

    PubMed

    Yukawa, Ken; Tachikawa, Noriko; Munakata, Motohiro; Shiota, Makoto; Kasugai, Shohei

    2014-03-01

    The purpose of this study was to investigate new patients who had already received treatment with dental implants. The subjects were patients who visited the clinic for oral implants at Tokyo Medical and Dental University Hospital from April 1995 to March 2012. The results were as follows: 1) Of the total number of patients, there were 2,419 patients (14.0%) with dental implants. 2) Of the 2,419 patients, 252 patients (10.4%) had been referred from operating doctors or operating clinics. 3) There were 1,516 (62.7%) patients with complaints related to the implant therapy. 4) There were 1,367 (56.5%) patients who had ill feelings toward their attending doctors. 5) There were 1,112 (46.0%) patients with biological complications. 6) Regarding patients with or without a referral from the doctor who had performed their dental implant, those patients who had been referred showed significantly higher occurrence of loss of implants, neurological symptoms, doctor's recommendation, prosthetic problems, and surgical problems. Almost implant therapies were treated with other treatments for natural teeth, including surgical treatment, prosthetic treatment, periodontal treatment and maintenance. These were too complex to enable the results to be forecast before treatment, therefore unpredictable symptoms often occur in patients with implant therapy. Informed consent including patient education is important, but the results of this study suggest that it is insufficient at present.

  11. Controlling the Biomimetic Implant Interface: Modulating Antimicrobial Activity by Spacer Design

    NASA Astrophysics Data System (ADS)

    Wisdom, Cate; Vanoosten, Sarah Kay; Boone, Kyle W.; Khvostenko, Dmytro; Arnold, Paul M.; Snead, Malcolm L.; Tamerler, Candan

    2016-08-01

    Surgical site infection is a common cause of post-operative morbidity, often leading to implant loosening, ultimately requiring revision surgery, increased costs and worse surgical outcomes. Since implant failure starts at the implant surface, creating and controlling the bio-material interface will play a critical role in reducing infection while improving host cell-to-implant interaction. Here, we engineered a biomimetic interface based upon a chimeric peptide that incorporates a titanium binding peptide (TiBP) with an antimicrobial peptide (AMP) into a single molecule to direct binding to the implant surface and deliver an antimicrobial activity against S. mutans and S. epidermidis, two bacteria which are linked with clinical implant infections. To optimize antimicrobial activity, we investigated the design of the spacer domain separating the two functional domains of the chimeric peptide. Lengthening and changing the amino acid composition of the spacer resulted in an improvement of minimum inhibitory concentration by a three-fold against S. mutans. Surfaces coated with the chimeric peptide reduced dramatically the number of bacteria, with up to a nine-fold reduction for S. mutans and a 48-fold reduction for S. epidermidis. Ab initio predictions of antimicrobial activity based on structural features were confirmed. Host cell attachment and viability at the biomimetic interface were also improved compared to the untreated implant surface. Biomimetic interfaces formed with this chimeric peptide offer interminable potential by coupling antimicrobial and improved host cell responses to implantable titanium materials, and this peptide based approach can be extended to various biomaterials surfaces.

  12. Neuropathic pain resulting from implant placement: case report and diagnostic conclusions.

    PubMed

    Leckel, M; Kress, B; Schmitter, M

    2009-07-01

    Temporary or persisting dysesthesia of the nervus alveolaris inferior has often been described as a complication of implant surgery of the lower mandible. In most cases, lesion of the nerve results in anaesthesia of the innervated region, a symptom clearly indicative of correct diagnosis. In our case report, however, a minor perforation of the roof of the mandibular canal during implant placement apparently provoked discrete irritation of the nerve, resulting in persistent neuropathic pain without concomitant hypesthesia or dysesthesia. Because the canal could not be detected in conventional dental radiographs, this uncharacteristic situation made correct diagnosis difficult and led to unnecessary surgical procedures including extraction of adjacent teeth. Medical imaging [computed tomography (CT)] finally revealed the close proximity of the apex of the implant and the bony structure of the mandibular canal. The effect on the nervus alveolaris inferior was also demonstrated using an innovative high-resolution dental magnetic-resonance-imaging technique reflecting vascular reactions of the neurovascular bundle after potentially damaging surgical intervention. After removal of the causative implant, the pain gradually faded over a period of a year.

  13. The effects of surgical preparation techniques and implant macro-geometry on primary stability: An in vitro study

    PubMed Central

    Severino, Marco; Rastelli, Claudio; Bernardi, Sara; Caruso, Silvia; Galli, Massimo; Lamazza, Luca; Di Paolo, Carlo

    2017-01-01

    Background The attainment of a good primary stability is a necessary condition to ensure the success of osseointegration in implantology. In type IV cancellous bone, however, it is possible that a reduced primary stability can lead to an increased rate of failure. The aim of this study was therefore to determine, with the help of the resonance frequency (Osstell mentor), which technique of implant site preparation (piezo surgery, conventional, under-preparation, bone compaction, osteodistraction) and macro-geometry is able to improve implant stability in type IV cancellous bone. Material and Methods 10 pig ribs were prepared with a surgical pre-drilled guide, calibrated for a correct implant positioning. On each rib, 5 implant sites (one for each technique) were prepared. Successively, 50 conical implants (Tekka Global D) were inserted and measured with the resonance frequency to evaluate the primary stability. Data collected were analyzed by analysis of variance (ANOVA) to test whether the Implant Stability Quotient (ISQ) values of the five techniques were significantly different. Results The results showed that no significant differences among the ISQ values of the five techniques used were found. Also, no significant differences in the macro-geometry of the two types of compared implants were observed. However, the macro-geometry of Tekka implants, characterized by a double condensing thread, seems to provide greater ISQ values than those of single thread implants when using the same technique. Conclusions In light of these preliminary data, it is conceivable that in cases of reduced stability, such as those occurring with a type IV bone, all means ameliorating the primary stability and accelerating the osseointegration can be utilized. Key words:Implant primary stability, resonance frequency analysis, implant site preparation. PMID:28160577

  14. Randomized Controlled Trial of Minimally Invasive Sacroiliac Joint Fusion Using Triangular Titanium Implants vs Nonsurgical Management for Sacroiliac Joint Dysfunction: 12-Month Outcomes.

    PubMed

    Polly, David W; Cher, Daniel J; Wine, Kathryn D; Whang, Peter G; Frank, Clay J; Harvey, Charles F; Lockstadt, Harry; Glaser, John A; Limoni, Robert P; Sembrano, Jonathan N

    2015-11-01

    Sacroiliac joint (SIJ) dysfunction is a prevalent cause of chronic, unremitting lower back pain. To concurrently compare outcomes after surgical and nonsurgical treatment for chronic SIJ dysfunction. A total of 148 subjects with SIJ dysfunction were randomly assigned to minimally invasive SIJ fusion with triangular titanium implants (n = 102) or nonsurgical management (n = 46). Pain, disability, and quality-of-life scores were collected at baseline and at 1, 3, 6, and 12 months. Success rates were compared using Bayesian methods. Crossover from nonsurgical to surgical care was allowed after the 6-month study visit was complete. Six-month success rates were higher in the surgical group (81.4% vs 26.1%; posterior probability of superiority > 0.9999). Clinically important (≥ 15 point) Oswestry Disability Index improvement at 6 months occurred in 73.3% of the SIJ fusion group vs 13.6% of the nonsurgical management group (P < .001). At 12 months, improvements in SIJ pain and Oswestry Disability Index were sustained in the surgical group. Subjects who crossed over had improvements in pain, disability, and quality of life similar to those in the original surgical group. Adverse events were slightly more common in the surgical group (1.3 vs 1.1 events per subject; P = .31). This Level 1 study showed that minimally invasive SIJ fusion using triangular titanium implants was more effective than nonsurgical management at 1 year in relieving pain, improving function, and improving quality of life in patients with SIJ dysfunction caused by degenerative sacroiliitis or SIJ disruptions. Pain, disability, and quality of life also improved after crossover from nonsurgical to surgical treatment.

  15. Surgical treatment in stenosing rectal cancer.

    PubMed

    Deaconescu, V; Simion, L; Alecu, M; Ionescu, S; Mastalier, B; Straja, N D

    2014-01-01

    Rectal cancer represents an important health issue, which involves multidisciplinary treatment, posing a major surgical challenge, both in terms of diagnosis and treatment. Between 2009-2013, we analysed 83 patients with stenosing rectal cancer operated on at the Clinic of General Surgery II of Colentina Clinical Hospital and at the Clinic of General Surgery I of "Prof. Dr. Al. Trestioreanu"€ Oncology Institute, in Bucharest. Gender distribution was: 51 males and 32 females. Average age was 65 years old. The most frequently encountered symptoms were colicky abdominal pain and rectorrhagia. 25 patients presented intestinal occlusion phenomena at admission, the other 58 cases being in subocclusive stage. In occlusive stages: 17 patients presented with resectable tumour, while 8 patients had locally advanced neoplastic forms (€œfrozen pelvis€), left iliac colostomy with tumour biopsy being the chosen approach. In subocclusive stages: 5 cases had unresectable tumours for which left iliac anus with tumour biopsy was performed; 53 cases presented with resectable tumour, for which the Hartmann procedure (12 patients) and left iliac colostomy with tumour biopsy (41 patients) were performed. Depending on the histopathological result, patients were submitted to radio- and chemotherapy.Tumour resection was possible in 70 cases (84.33%), only 34 of these (40.96%) being with radical intent. Treatment for stenosing rectal cancer is multimodal,represented by surgical approach, radio- and chemotherapy. The rationality behind surgery as a first therapeutic gesture in the given study group was represented by the need to treat occlusive type complications, patients benefitting subsequently from radio- and chemotherapy. The opportunity of a second surgical intervention, with the objective to remove the tumour, was established based on the therapeutic response to radio- and chemotherapy. Celsius.

  16. The utility of 3D printing for surgical planning and patient-specific implant design for complex spinal pathologies: case report.

    PubMed

    Mobbs, Ralph J; Coughlan, Marc; Thompson, Robert; Sutterlin, Chester E; Phan, Kevin

    2017-04-01

    OBJECTIVE There has been a recent renewed interest in the use and potential applications of 3D printing in the assistance of surgical planning and the development of personalized prostheses. There have been few reports on the use of 3D printing for implants designed to be used in complex spinal surgery. METHODS The authors report 2 cases in which 3D printing was used for surgical planning as a preoperative mold, and for a custom-designed titanium prosthesis: one patient with a C-1/C-2 chordoma who underwent tumor resection and vertebral reconstruction, and another patient with a custom-designed titanium anterior fusion cage for an unusual congenital spinal deformity. RESULTS In both presented cases, the custom-designed and custom-built implants were easily slotted into position, which facilitated the surgery and shortened the procedure time, avoiding further complex reconstruction such as harvesting rib or fibular grafts and fashioning these grafts intraoperatively to fit the defect. Radiological follow-up for both cases demonstrated successful fusion at 9 and 12 months, respectively. CONCLUSIONS These cases demonstrate the feasibility of the use of 3D modeling and printing to develop personalized prostheses and can ease the difficulty of complex spinal surgery. Possible future directions of research include the combination of 3D-printed implants and biologics, as well as the development of bioceramic composites and custom implants for load-bearing purposes.

  17. Surgical anatomy of the round window-Implications for cochlear implantation.

    PubMed

    Luers, J C; Hüttenbrink, K B; Beutner, D

    2018-04-01

    The round window is an important portal for the application of active hearing aids and cochlear implants. The anatomical and topographical knowledge about the round window region is a prerequisite for successful insertion for a cochlear implant electrode. To sum up current knowledge about the round window anatomy and to give advice to the cochlear implant surgeon for optimal placement of an electrode. Systematic Medline search. Search term "round window[Title]" with no date restriction. Only publications in the English Language were included. All abstracts were screened for relevance, that is a focus on surgical anatomy of the round window. The search results were supplemented with hand searching of selected reviews and reference lists from included studies. Subjective assessment. There is substantial variability in size and shape of the round window. The round window is regarded as the most reliable surgical landmark to safely locate the scala tympani. Factors affecting the optimal trajectory line for atraumatic electrode insertion are anatomy of the round window, the anatomy of the intracochlear hook region and the variable orientation and size of the cochlea's basal turn. The very close relation to the sensitive inner ear structures necessitates a thorough anatomic knowledge and careful insertion technique, especially when implanting patients with residual hearing. In order to avoid electrode migration between the scalae and to achieve protect the modiolus and the basilar membrane, it is recommended to aim for an electrode insertion vector from postero-superior to antero-inferior. © 2017 John Wiley & Sons Ltd.

  18. Stereotaxic Irradiation-Procedure of Brain Tumors and Pituitary Adenomas by Means of Radio-Isotopes and its Results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mundinger, F.; Riechert, T.

    1962-01-01

    The techniques, results, and complications of stereotactic implantation of P/sup 32/, Co/sup 60/, Ta/sup 182/, Ir/sup 192/, and Au/sup 198/ in the brain of 196 patients for radiotherapy of intracranial tumors are described. A stereotactic instrument is described and illustrated which permits implantation of the radioisotopes to within 0.5 mm of the desired site. There was a clear relation between the length of survival and the kind of radioisotope applied, localization of the tumor, and amount of the tumor dosage. With glioblastomas, for instance, longest survival was noted in those with frontal localization, following Co/sup 60/ irradiation, and an averagemore » tumor dosage of 10000 to 13000 r showed best results. Similar results, with even longer survival periods, were achieved in other dedifferentiated gliomas, in which the combination of intraoperative Ta/sup 182/ or Ir/sup 192/ implantation with a postoperative interstitial Co/sup 60/ irradiation achieved the best results, in comparison with a combination of operation and x-ray therapy. The survival rate, which is nearly twice as high as in x-ray treatment, shows a significant relation to the average tumor dosage and tumor localization. The period of treatment was also shortened by 65-75% compared to the time required for fractionated x-ray therapy. In 68% of the stereotaxic hypophysis operations, according to the size of the tumor, a total activity of 25 to 55 mc of a macromolecular suspension of Au/sup 198/ was implanted which was adsorbed on small graphite particles (50 to 60 mu ). In the other cases small seeds of P/sup 32/ were placed in the tumor. The long-term results show that visual acuity had improved significantly following secondary stereotaxic irradiation, or remained unaltered without change, in comparison to those patients that had been treated by operation only. On the other hand, the percentage of unimproved and deteriorated cases is much higher in the operated group. The operative mortality with primary stereotaxic punctures was nil, whereas surgical operative mortality totaled 19%. The survival rates of 90.4% of the patients with secondary stereotaxic irradiation and 76.1% with primary stereotaxic irradiation, in compari-son with only 62% of patients with operation only, prove significantly that effectively implanted interstitial irradiation can prolong life. Among operative complications, damage to the neighboring structures was not caused by stereotaxic puncture, but was caused secondarily by radiation, above all by gamma radiation. In six of the patients, therefore, an open decompression operation was necessary. There were some general transitory reactions in the first days, especially headache and cerebrospinal fluid pressure increase among recurrent and long-term complications, in 11.5%, visual acuity grew worse and the visual field was narrowed after 0.3 to 3 yr. It was concluded that primary, and especially secondary stereotaxic irradiation of hypophysis adenomas is clearly superior to surgical operation as concerns operative mortality as well as survival rate and rate of recurrence. The rate of improvement of visual acuity was 26 to 44% higher and that of the visual field 17 to 29% higher than following surgical operation only. However, one problem not yet solved satisfactorily is the long-term radiation damage of the chiasma and optic nerve. Perhaps filling the basal cisterns with x-ray contrast medium by means of the target needle, before the placing of the isotopes, may be of help in preventing this. (BBB)« less

  19. Implant for in-vivo parameter monitoring, processing and transmitting

    DOEpatents

    Ericson, Milton N [Knoxville, TN; McKnight, Timothy E [Greenback, TN; Smith, Stephen F [London, TN; Hylton, James O [Clinton, TN

    2009-11-24

    The present invention relates to a completely implantable intracranial pressure monitor, which can couple to existing fluid shunting systems as well as other internal monitoring probes. The implant sensor produces an analog data signal which is then converted electronically to a digital pulse by generation of a spreading code signal and then transmitted to a location outside the patient by a radio-frequency transmitter to an external receiver. The implanted device can receive power from an internal source as well as an inductive external source. Remote control of the implant is also provided by a control receiver which passes commands from an external source to the implant system logic. Alarm parameters can be programmed into the device which are capable of producing an audible or visual alarm signal. The utility of the monitor can be greatly expanded by using multiple pressure sensors simultaneously or by combining sensors of various physiological types.

  20. Implantable device for in-vivo intracranial and cerebrospinal fluid pressure monitoring

    DOEpatents

    Ericson, Milton N.; McKnight, Timothy E.; Smith, Stephen F.; Hylton, James O.

    2003-01-01

    The present invention relates to a completely implantable intracranial pressure monitor, which can couple to existing fluid shunting systems as well as other internal monitoring probes. The implant sensor produces an analog data signal which is then converted electronically to a digital pulse by generation of a spreading code signal and then transmitted to a location outside the patient by a radio-frequency transmitter to an external receiver. The implanted device can receive power from an internal source as well as an inductive external source. Remote control of the implant is also provided by a control receiver which passes commands from an external source to the implant system logic. Alarm parameters can be programmed into the device which are capable of producing an audible or visual alarm signal. The utility of the monitor can be greatly expanded by using multiple pressure sensors simultaneously or by combining sensors of various physiological types.

  1. Outcomes of flapless crestal maxillary sinus elevation under hydraulic pressure.

    PubMed

    Bensaha, Tarik

    2012-01-01

    Sinus elevation through the crestal approach has become a routine procedure for implant placement in the posterior edentulous maxilla. The combination of flapless surgery and crestal sinus elevation with simultaneous placement of implants is an attractive surgical approach for implant grafting in the posterior maxilla, but its efficacy and safety have seldom been studied. The aim of this study is to evaluate retrospectively the outcomes of flapless crestal sinus floor elevation using piezosurgery and a hydraulic sinus elevation system with simultaneous implant placement. Between October 2009 and August 2010, flapless implant surgery using a crestal approach, accompanied by simultaneous hydraulic sinus elevation and grafting, was performed. Patients were followed up clinically and with intraoral and panoramic radiographs. Any postoperative complications, including swelling, discomfort, infection, fractures, and implant loss, were recorded, and sinus bone gain was measured. Thirty-one sinuses were elevated and 35 implants were placed. Patients were a mean of 41.2 ± 6.69 years old, and 45% were women. The sinus was elevated to 7 to 15 mm, and no membrane perforations were noted. The mean follow-up period was 21 weeks. The mean bone gain under the maxillary sinus was 12.03 ± 2.1 mm, and all implants displayed primary stability with a mean insertion torque ≥ 15 Ncm. No postoperative discomfort, swelling, hematoma, infection, or bone fenestration was noted. One patient experienced prolonged edema in the lower eyelid region, and another lost an implant. In this retrospective analysis, flapless crestal sinus floor elevation was safe and effective, decreasing surgical discomfort and trauma and early implant failures.

  2. Low pacemaker incidence with continuous-sutured valves: a retrospective analysis.

    PubMed

    Niclauss, Lars; Delay, Dominique; Pfister, Raymond; Colombier, Sebastien; Kirsch, Matthias; Prêtre, René

    2017-06-01

    Background Permanent pacemaker implantation after surgical aortic valve replacement depends on patient selection and risk factors for conduction disorders. We aimed to identify risk criteria and obtain a selected group comparable to patients assigned to transcatheter aortic valve implantation. Methods Isolated sutured aortic valve replacements in 994 patients treated from 2007 to 2015 were reviewed. Demographics, hospital stay, preexisting conduction disorders, surgical technique, and etiology in patients with and without permanent pacemaker implantation were compared. Reported outcomes after transcatheter aortic valve implantation were compared with those of a subgroup including only degenerative valve disease and first redo. Results The incidence of permanent pacemaker implantation was 2.9%. Longer hospital stay ( p = 0.01), preexisting rhythm disorders ( p < 0.001), complex prosthetic endocarditis ( p = 0.01), and complex redo ( p < 0.001) were associated with permanent pacemaker implantation. Although prostheses were sutured with continuous monofilament in the majority of cases (86%), interrupted pledgetted sutures were used more often in the pacemaker group ( p = 0.002). In the subgroup analysis, the incidence of permanent pacemaker implantation was 2%; preexisting rhythm disorders and the suture technique were still major risk factors. Conclusion Permanent pacemaker implantation depends on etiology, preexisting rhythm disorders, and suture technique, and the 2% incidence compares favorably with the reported 5- to 10-fold higher incidence after transcatheter aortic valve implantation. Cost analysis should take this into account. Often dismissed as minor complication, permanent pacemaker implantation increases the risks of endocarditis, impaired myocardial recovery, and higher mortality if associated with prosthesis regurgitation.

  3. Translation of First North American 50 and 70 cc Total Artificial Heart Virtual and Clinical Implantations: Utility of 3D Computed Tomography to Test Fit Devices.

    PubMed

    Ferng, Alice S; Oliva, Isabel; Jokerst, Clinton; Avery, Ryan; Connell, Alana M; Tran, Phat L; Smith, Richard G; Khalpey, Zain

    2017-08-01

    Since the creation of SynCardia's 50 cc Total Artificial Hearts (TAHs), patients with irreversible biventricular failure now have two sizing options. Herein, a case series of three patients who have undergone successful 50 and 70 cc TAH implantation with complete closure of the chest cavity utilizing preoperative "virtual implantation" of different sized devices for surgical planning are presented. Computed tomography (CT) images were used for preoperative planning prior to TAH implantation. Three-dimensional (3D) reconstructions of preoperative chest CT images were generated and both 50 and 70 cc TAHs were virtually implanted into patients' thoracic cavities. During the simulation, the TAHs were projected over the native hearts in a similar position to the actual implantation, and the relationship between the devices and the atria, ventricles, chest wall, and diaphragm were assessed. The 3D reconstructed images and virtual modeling were used to simulate and determine for each patient if the 50 or 70 cc TAH would have a higher likelihood of successful implantation without complications. Subsequently, all three patients received clinical implants of the properly sized TAH based on virtual modeling, and their chest cavities were fully closed. This virtual implantation increases our confidence that the selected TAH will better fit within the thoracic cavity allowing for improved surgical outcome. Clinical implantation of the TAHs showed that our virtual modeling was an effective method for determining the correct fit and sizing of 50 and 70 cc TAHs. © 2016 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  4. A Clinical Implant Program in the Predoctoral Curriculum.

    ERIC Educational Resources Information Center

    Bell, Fred A.; And Others

    1991-01-01

    Six senior dental students participated in a preprosthetic surgery clinic and then performed implant surgery on patients. Patient reactions were highly favorable. Students and faculty found the prosthodontic phase more difficult than the surgical. Program continuation at the predoctoral level is anticipated. (MSE)

  5. Decontamination of dental implant surface in peri-implantitis treatment: A literature review

    PubMed Central

    Buitrago-Vera, Pedro; Solá-Ruiz, María F.; Ferrer-García, Juan C.

    2013-01-01

    Etiological treatment of peri-implantitis aims to reduce the bacterial load within the peri-implant pocket and decontaminate the implant surface in order to promote osseointegration. The aim of this literature review was to evaluate the efficacy of different methods of implant surface decontamination. A search was conducted using the PubMed (Medline) database, which identified 36 articles including in vivo and in vitro studies, and reviews of different decontamination systems (chemical, mechanical, laser and photodynamic therapies). There is sufficient consensus that, for the treatment of peri-implant infections, the mechanical removal of biofilm from the implant surface should be supplemented by chemical decontamination with surgical access. However, more long-term research is needed to confirm this and to establish treatment protocols responding to different implant characterics. Key words:Peri-implantitis, treatment, decontamination, implant surface, laser. PMID:23986023

  6. Virtual Surgical Planning in Craniofacial Surgery

    PubMed Central

    Chim, Harvey; Wetjen, Nicholas; Mardini, Samir

    2014-01-01

    The complex three-dimensional anatomy of the craniofacial skeleton creates a formidable challenge for surgical reconstruction. Advances in computer-aided design and computer-aided manufacturing technology have created increasing applications for virtual surgical planning in craniofacial surgery, such as preoperative planning, fabrication of cutting guides, and stereolithographic models and fabrication of custom implants. In this review, the authors describe current and evolving uses of virtual surgical planning in craniofacial surgery. PMID:25210509

  7. Self-expandable CoreValve implantation without contrast media.

    PubMed

    Bruschi, Giuseppe; Colombo, Paola; De Marco, Federico; Barosi, Alberto; Mauri, Silvia; Klugmann, Silvio

    2016-09-01

    Transcatheter aortic valve implantation has been designed to treat high-risk surgical patients affected by severe aortic stenosis, many of whom are affected by chronic kidney disease. To perform transcatheter self-expandable valve implantation, multiple contrast injections are required to monitor the procedure, so these patients are at increased risk of acute kidney injury. We described self-expandable transcatheter aortic valve implantation without contrast media in an 80-year-old man affected by severe aortic stenosis and endstage chronic kidney disease. © The Author(s) 2015.

  8. Alloplastic implants for orbital wall reconstruction.

    PubMed

    Jacono, A A; Moskowitz, B

    2000-01-01

    Nonabsorbable alloplastic implants for orbital wall reconstruction have been widely accepted by surgeons because of their ready availability, stability, and biocompatability. Many complications have arisen with this class of implants because the lack of host tissue integration allows for implant migration, implant extrusion, recurrent hemorrhage, and infection. Porous polyethylene implants provide a welcome alternative as they have the unique properly of supporting tissue ingrowth in vivo. Their semirigid structure provides structural stability when used around the orbit, and their malleability allows for easy contouring. This paper presents our surgical approach to reconstructing orbital defects with porous polyethylene implants, including orbital floor, and superior, medial, and lateral wall defects, and discusses the advantages/disadvantages of other nonabsorbable alloplasts.

  9. Advanced immediate functional loading: requirements for long-term success in modern implant dentistry.

    PubMed

    Romanos, Georgios E

    2014-01-01

    There are benefits to be derived from the use of advanced surgical protocols in conjunction with immediate functional loading using various dental implant designs and implant-abutment connections. Clinical protocols with simultaneous bone grafting, immediate implant placement, and/or sinus augmentations when a shortened treatment period is needed are included in this report, with the aim of providing understanding of the main protocol characteristics and prerequisites for long-term success in implant dentistry. This article presents three clinical cases that illustrate possibilities for advanced immediate loading using different implant designs. It demonstrates treatment of severe bone defects and the facilitation of placing implants in regenerated bone that can be immediately loaded.

  10. Scanning-electron-microscopy observations and mechanical characteristics of ion-beam-sputtered surgical implant alloys

    NASA Technical Reports Server (NTRS)

    Weigand, A. J.; Meyer, M. L.; Ling, J. S.

    1977-01-01

    An electron bombardment ion thruster was used as an ion source to sputter the surfaces of orthopedic prosthetic metals. Scanning electron microscopy photomicrographs were made of each ion beam textured surface. The effect of ion texturing an implant surface on its bond to bone cement was investigated. A Co-Cr-W alloy and surgical stainless steel were used as representative hard tissue implant materials to determine effects of ion texturing on bulk mechanical properties. Work was done to determine the effect of substrate temperature on the development of an ion textured surface microstructure. Results indicate that the ultimate strength of the bulk materials is unchanged by ion texturing and that the microstructure will develop more rapidly if the substrate is heated prior to ion texturing.

  11. Surgery of the globe and orbit.

    PubMed

    Cho, Jane

    2008-02-01

    Orbital anatomy and the indications and surgical techniques for a variety of small animal orbital/globe surgical procedures are discussed. Details of the more common orbital surgical procedures, including ocular evisceration, intrascleral prosthesis implantation, enucleation, and proptosis repair, are given. Common complications and postoperative considerations for these procedures are also discussed with an emphasis on the practical aspects.

  12. Surgical considerations and safety of cochlear implantation in otitis media with effusion.

    PubMed

    Cevizci, Rasit; Dilci, Alper; Celenk, Fatih; Karamert, Recep; Bayazit, Yildirim

    2018-06-01

    To evaluate the effects of otitis media with effusion on surgical parameters, patient safety, perioperative and postoperative complications. Total 890 children who underwent cochlear implantation between 2006 and 2015 were included. The ages ranged from 12 months to 63 months (mean: 32 months). The patients were divided into two groups according to the presence or absence of otitis media with effusion; otitis media with effusion group and non-otitis media group. Of 890 children, 105 had otitis media with effusion prior to surgery. In non-otitis media with group, there were 785 children. The average duration of surgery was 60min (ranged from 28 to 75min) in non-otitis media group, and 90min (ranged from 50 to 135min) in otitis media with effusion group (p<0.05). Granulation tissue and edematous middle ear and mastoid mucosa were observed in all cases of otitis media with effusion during the surgery. There was no significant difference between the complications of groups with or without otitis media with effusion (p>0.05). In 5 of 105 patients, there was a ventilation tube inserted before cochlear implantation, which did not change the outcome of implantation. There is no need for surgical treatment for otitis media with effusion before implantation since otitis media with effusion does not increase the risks associated with cochlear implantation. Operation duration is longer in the presence of otitis media with effusion. However, otitis media with effusion leads to intraoperative difficulties like longer operation duration, bleeding, visualization of the round window membrane, cleansing the middle ear granulations as well as mastoid and petrous air cells. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Evaluation of ion-implanted-silicon detectors for use in intraoperative positron-sensitive probes.

    PubMed

    Raylman, R R; Wahl, R L

    1996-11-01

    The continuing development of probes for use with beta (positron and electron) emitting radionuclides may result in more complete excision of tracer-avid tumors. Perhaps one of the most promising radiopharmaceuticals for this task is 18F-labeled-Fluoro-2-Deoxy-D-Glucose (FDG). This positron-emitting agent has been demonstrated to be avidly and rapidly absorbed by many human cancers. We have investigated the use of ion-implanted-silicon detectors in intraoperative positron-sensitive surgical probes for use with FDG. These detectors possess very high positron detection efficiency, while the efficiency for 511 keV photon detection is low. The spatial resolution, as well as positron and annihilation photon detection sensitivity, of an ion-implanted-silicon detector used with 18F was measured at several energy thresholds. In addition, the ability of the device to detect the presence of relatively small amounts of FDG during surgery was evaluated by simulating a surgical field in which some tumor was left intact following lesion excision. The performance of the ion-implanted-silicon detector was compared to the operating characteristics of a positron-sensitive surgical probe which utilizes plastic scintillator. In all areas of performance the ion-implanted-silicon detector proved superior to the plastic scintillator-based probe. At an energy threshold of 14 keV positron sensitivity measured for the ion-implanted-silicon detector was 101.3 cps/kBq, photon sensitivity was 7.4 cps/kBq. In addition, spatial resolution was found to be relatively unaffected by the presence of distant sources of annihilation photon flux. Finally, the detector was demonstrated to be able to localize small amounts of FDG in a simulated tumor bed; indicating that this device has promise as a probe to aid in FDG-guided surgery.

  14. Effects of Percutaneous LVAD Support on Right Ventricular Load and Adaptation.

    PubMed

    Yourshaw, Jeffrey P; Mishra, Prabodh; Armstrong, M Christopher; Ramu, Bhavadharini; Craig, Michael L; Van Bakel, Adrian B; Steinberg, Daniel H; DiSalvo, Thomas G; Tedford, Ryan J; Houston, Brian A

    2018-04-30

    Both operative and hemodynamic mechanisms have been implicated in right heart failure (RHF) following surgical left ventricular assist device (LVAD) implantation. We investigated the effects of percutaneous LVAD (pLVAD; Impella®, Abiomed) support on right ventricular (RV) load and adaptation. We reviewed all patients receiving a pLVAD for cardiogenic shock at our institution between July 2014 and April 2017, including only those with pre- and post-pLVAD invasive hemodynamic measurements. Hemodynamic data was recorded immediately prior to pLVAD implantation and up to 96 h post-implantation. Twenty-five patients were included. Cardiac output increased progressively during pLVAD support. PAWP improved early post-pLVAD but did not further improve during continued support. Markers of RV adaptation (right ventricular stroke work index, right atrial pressure (RAP), and RAP to pulmonary artery wedge pressure ratio (RAP:PAWP)) were unchanged acutely implant but progressively improved during continued pLVAD support. Total RV load (pulmonary effective arterial elastance; E A ) and resistive RV load (pulmonary vascular resistance; PVR) both declined progressively. The relationship between RV load and RV adaptation (E A /RAP and E A /RAP:PAWP) was constant throughout. Median vasoactive-inotrope score declined after pLVAD placement and continued to decline throughout support. Percutaneous LVAD support in patients with cardiogenic shock did not acutely worsen RV adaptation, in contrast to previously described hemodynamic effects of surgically implanted durable LVADs. Further, RV load progressively declined during support, and the noted RV adaptation improvement was load-dependent as depicted by constant E A /RA and E A /RAP:PAWP relationships. These findings further implicate the operative changes associated with surgical LVAD implantation in early RHF following durable LVAD.

  15. [Implantation of intraocular lenses in the ciliary sulcus].

    PubMed

    Schulze, S; Bertelmann, T; Sekundo, W

    2014-04-01

    Implantation of an intraocular lens (IOL) into the ciliary sulcus is the second most common implantation site after the regular capsular bag (in the bag) placement of an IOL. Although mainly not primarily intended, it is very often used in both complicated cataract surgery and secondary implantation due to IOL dislocation or aphakia. In most cases stable positioning is possible, especially when using optic capture techniques. A variety of difficulties can occur with sulcus implantation depending on the anatomical and surgical conditions present at the time of implantation. The most anterior position of the sulcus lense has to be considered for calculation of the refractive power of the IOL.

  16. [Current issues, problems and prospects of tension-free hernioplasty (review)].

    PubMed

    2014-01-01

    In the present study there are discussed modern methods of the tension free hernioplastics, the complications associated with them and technical difficulties, up-to-date views and the perspectives of the issue development in terms of avoiding infectious complications, positioning of implants and their fixation. Hernia is one of the widespread surgical pathologies as it is found in 4% of the population and its share among the inpatient surgical diseases is about 18-30%. Consequently annually up to 20-21 mln hernioplasties are carried out worldwide. Despite of many years of experience in the field of hernia surgical treatment there still exist many unsolved problems such as safe closure of defects of abdominal cavity wall. Up to 200 methods of hernioplastics, various implantations and application of synthetic materials refer to lack of the optimal surgical strategy. In modern herniology priorities are given to tension free plastics. The merge of the synthetic implants and "tension free hernioplastics" concepts enabled sharp reduction of the side effects list, making it possible to perform successful surgeries in that contingent whose treatment by the method of tissue-plasty was related with high risk of lethality. Large scale introduction of tension free hernioplastics caused intensification of the associated problems such as migration, dissection and shortening of the net.

  17. MRI evaluation of post-mastectomy irradiated breast implants: prevalence and analysis of complications.

    PubMed

    Rella, L; Telegrafo, M; Nardone, A; Milella, A; Stabile Ianora, A A; Lioce, M; Angelelli, G; Moschetta, M

    2015-09-01

    To evaluate the effect of post-mastectomy radiation therapy (RT) on breast implants as detected by magnetic resonance imaging (MRI) searching for short-term complications. One hundred and forty patients (total of 144 implants) were evaluated by MRI; 80 (group 1) had undergone RT, whereas the remaining 60 patients (group 2) underwent mastectomy with implant reconstruction without RT. Two radiologists evaluated MRI images searching for implant rupture signs, sub-capsular seromas, capsular contracture, soft-tissue oedema, peri-implant fluid collections. Implant ruptures were classified as severe complications; seromas and capsular contractures as moderate complications; oedema and fluid collections as mild complications. The prevalence of MRI findings in the two groups was calculated and compared by unpaired t-test. Cohen's kappa statistics was used to assess interobserver agreement. Sixty-nine out of 144 (48%) implants presented pathological findings at MRI with complication rates of 47.5 and 48.4 for groups 1 and 2, respectively. Two (5%) severe complications, 10 (26%) moderate complications, and 26 (69%) mild complications occurred in group 1 and surgical treatment was performed in 10 cases. Two (6%) severe complications, seven (23%) moderate complications, and 22 (71%) mild complications occurred in group 2 and surgical treatment was performed in eight cases. No significant difference between the two groups was found (p>0.1). Almost perfect agreement between the two radiologists was found for MRI image detection (k=0.86). RT does not seem to cause a significant effect on breast implants in terms of complication rate in patients undergoing implant-based breast reconstruction. One-stage immediate implant-based breast reconstruction performed at the same time as mastectomy could be proposed. Copyright © 2015 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  18. Revision total hip arthroplasty: the femoral side using cemented implants.

    PubMed

    Holt, Graeme; Hook, Samantha; Hubble, Matthew

    2011-02-01

    Advances in surgical technique and implant technology have improved the ten-year survival after primary total hip arthroplasty (THA). Despite this, the number of revision procedures has been increasing in recent years, a trend which is predicted to continue into the future. Revision THA is a technically demanding procedure often complicated by a loss of host bone stock which may be compounded by the need to remove primary implants. Both cemented and uncemented implant designs are commonly used in the United Kingdom for primary and revision THA and much controversy still exists as to the ideal method of stem fixation. In this article we discuss revision of the femur using cemented components during revision THA. We focus on three clinical scenarios including femoral cement-in-cement revision where the primary femoral cement-bone interface remains well fixed, femoral cement-in-cement revision for peri-prosthetic femoral fractures, and femoral impaction grafting. We discuss the clinical indications, surgical techniques and clinical outcomes for each of these procedures.

  19. Edentulous maxillary arch fixed implant rehabilitation using a hybrid prosthesis made of micro-ceramic-composite: case report.

    PubMed

    Geckili, Onur; Bilhan, Hakan; Ceylan, Gulsum; Cilingir, Altug

    2013-02-01

    The prosthetic treatment of patients with an edentulous maxilla opposing mandibular natural teeth is one of the most challenging endeavors that face clinicians. Occlusal forces from the opposing natural teeth may cause fractures in the maxillary prosthesis and also result in advanced bone loss of the edentulous maxilla. With the presence of extreme gagging reflex, the treatment may become more complicated. This article describes and illustrates the 2-stage surgical and prosthetic treatment of a patient with an edentulous maxilla opposing natural teeth. In the beginning, the patient was treated with 4 implants and a maxillary implant-supported overdenture. The extreme gagging reflex and the occlusal forces from the mandibular natural teeth obligated the team a second stage surgical and prosthetic treatment, which included increasing the number of implants after bilateral sinus lifting in the posterior maxilla and fabricating a maxillary fixed hybrid prosthesis made of micro-ceramic composite that yielded a satisfactory result.

  20. Real-time Non-invasive Spectral Imaging of Orthotopic Red Fluorescent Protein-expressing Lung Tumor Growth in Nude Mice.

    PubMed

    Zhang, Yong; Zhang, Nan; Zhao, Ming; Hoffman, Robert M

    2015-07-01

    Orthotopic implantation of cancer allows metastasis to occur. The most patient-like metastatic orthotopic models are developed with surgical orthotopic implantation using intact tissue in order to preserve the natural tissue structure of the tumor which contains both cancer cells and stroma. In the present study, we performed a simple thoracotomy by making an intercostal incision between the fourth and fifth ribs on the left side of the chest of nude mice. Lung tumor fragments expressing red fluorescent protein were then implanted on the left lung. It was possible to monitor tumor formation in the lung non-invasively by spectral imaging using the Maestro system with a liquid tunable filter. The model described here has high tumorigenicity in the lung (100%) and a low mortality rate (5%). This imageable nude mouse model using surgical orthotopic implantation of lung cancer will be useful for all types of longitudinal studies. Copyright© 2015 International Institute of Anticancer Research (Dr. John G. Delinassios), All rights reserved.

Top