DOE Office of Scientific and Technical Information (OSTI.GOV)
Barham, R.E.; Butz, G.W.; Ansell, J.S.
Wound strength in the rectus muscle of rabbits is greater at any measured time interval when sutured with polyglycolic acid than when sutured with chromic catgut. This is true for both irradiated and nonirradiated tissues. No significant advantage is seen for either suture in nonirradiated bladder, although the trend favors polyglycolic acid. In irradiated bladders, a significant advantage is seen for polyglycolic acid at 15 days. In measuring repaired ureteral orifice size, only chromic catgut suture in nonirradiated rabbits caused marked edema and ureteral obstruction. Postoperative ureteral dilation with both materials resolved over a 90 day period. In the irradiatedmore » ureter, however, resolution of this obstruction appears to occur earlier and more dependably when polyglycolic acid suture has been used. Polyglycolic acid showed a trend for superior strength in urothelial wounds tested. The healing of bladder epithelium is usually completed in ten to 14 days. The entire bladder wound gains strength rapidly until day 21 and gains little strength thereafter. A suture material that does not increase the inflammatory response but lasts long enough for complete bladder healing is advisable. Using the criterion of wound breaking strength in our experimental work, polyglycolic acid was shown to be superior to chromic catgut suture material.« less
Ozkan, Mehmet; Astarcioglu, Mehmet Ali; Karakoyun, Suleyman; Balkanay, Mehmet
2012-02-01
Obstruction to a prosthetic cardiac valve is a well-recognized complication of cardiac valve replacement. Malfunction of the mobile component of a prosthetic valve to open or close correctly may occur in consequence of intrinsic or extrinsic causes (thrombus, vegetation, entrapment of left ventricular myocardium, suture entanglement, and pannus formation) that may result prosthetic valve stenosis and/or insufficiency. In the case we report a 48-year-old female with valve dysfunction occurred early after surgery, as one valve leaflet was only able to partially open due to suture entrapment. © 2011, Wiley Periodicals, Inc.
Shah, Hemendra N; Nayyar, Rishi; Rajamahanty, Shrinivas; Hemal, Ashok K
2012-06-01
To evaluate the usage of unidirectional barbed suture and its related implications in various surgeon-controlled robotic reconstructive urologic surgeries. From March 2010 to March 2011, all patients undergoing various surgeon-controlled robotic reconstructive urologic surgeries utilizing barbed sutures were prospectively enrolled in this study. Type and number of procedure performed were noted. Intraoperative and peri-operative outcomes potentially related to suture technique and material were recorded. This study reports on 210 patients, in whom barbed suture was used during this period. These included partial nephrectomy (20), pyeloplasty (9), ureteric tailoring and reimplantation (1), closure of bladder after Nephroureterectomy with excision of bladder cuff (8), closure of vaginal cuff in female radical cystectomy (12), partial cystectomy (1), radical prostatectomy (152), simple prostatectomy (2), vesicovaginal fistula repair (3), sacrocolpopexy (1), and hernia repair (1). We encountered 5 instances (2.38%) of tissue cut through possibly attributable to the use of barbed suture and 4 instances of misplacement of suture occurred, of these two required a new suture, whereas retrograde pull back of suture and needle was performed in 2 cases. No instance of slip back/loosening of suture was noted once it was tightened. At mean follow-up of 6.8 (1-14 months) months, we did not encounter any complications of urinary leakage, stone formation or fistula or any clinical evidence of urinary tract obstruction due to the use of barbed suture. Use of unidirectional barbed suture is safe, feasible, and efficient at short-term follow-up for reconstructive part of urological procedures.
[Clinical application of biofragmentable anastomosis ring for intestinal anastomosis].
Ye, Feng; Lin, Jian-jiang
2006-11-01
To compare the efficacy of the biofragmentable anastomotic ring (BAR) with conventional hand-sutured and stapling techniques,and to evaluate the safety and applicability of the BAR in intestinal anastomosis. The totol of 498 patients performed intestinal anastomosis from January 2000 to November 2005 were allocated to BAR group (n=186), hand-sutured group (n=177) and linear cutter group (n=135). The operative time, postoperative convalescence and corresponding complication were recorded. Postoperative anastomotic inflammation and anastomotic stenosis were observed during half or one year follow-up of 436 patients. The operative time was (102 +/- 16) min in the BAR group, (121 +/- 15) min in the hand-sutured group, and (105 +/- 18 ) min in the linear cutter group. The difference was significant statistically (P <0.05). The operative time in BAR group and linear cutter group was shorter than hand-sutured group. One case of anastomotic leakage was noted in the BAR group, one case in the hand-sutured group, and none in the linear cutter group. They were cured by conservative methods. One case of anastomotic obstruction happened in the BAR group, one case in the hand-sutured group. Two of them were cured by conservative methods. Two cases of anastomotic obstruction happened in the hand-sutured group. However, one of them required reoperation to remove the obstruction. In the BAR, hand-sutured and the linear cutter group, the postoperative first flatus time was (67.2+/- 4.6) h, (70.2 +/- 5.8) h and (69.2 +/- 6.2)h, respectively. No significant differences were observed among three groups(P > 0.05). The rate of postoperative anastomotic inflammation was 3.0 % (5/164) in the BAR group, 47.8 % (76/159) in hand-sutured group and 7.1 % (8/113) in the linear cutter group. The difference was significant statistically (P <0.05). The rate of postoperative anastomotic inflammation in the BAR group and in the linear cutter group was less than that in hand-sutured group. BAR is one of rapid,safe and effective methods in intestinal anastomosis. It has less anastomotic inflammatory reaction than hand-sutured technique. It should be considered equal to manual and stapler methods.
Kim, Eun Young; Hong, Tae Ho
2016-04-01
We describe our laparoscopic longitudinal pancreaticojejunostomy (LPJ) technique using barbed sutures to manage a pancreatic duct obstruction. We performed laparoscopic longitudinal anterior pancreaticojejunostomy using barbed sutures (3-0 absorbable wound closure device, V-Loc, Covidien, Minneapolis, MN, USA) in 11 patients who presented with signs of a pancreas ductal obstruction and chronic pancreatitis. The surgical outcomes and follow-up records at the outpatient department were reviewed, and the effectiveness and feasibility of this method were analyzed. Mean patient age was 54.4 ± 9.5 years, and pancreatic duct stones were removed from all patients without conversion to laparotomy. Overall operative time was 200.7 ± 56.4 min, and estimated blood loss was 42.2 ± 11.2 ml. No pancreatic anastomosis leakage or postoperative bleeding was detected. Mean length of hospital stay was 6.5 ± 0.8 days, and mean time to start a soft diet was 4.8 ± 0.7 days. No patient complained of postoperative abdominal pain, and all patients recovered without significant complications or relapse of pancreatitis. The follow-up period was 4-21 months. Our new laparoscopic longitudinal anterior pancreaticojejunostomy technique (Puestow procedure) using barbed sutures is a potentially efficient and minimally invasive procedure for patients who suffer from pancreatic duct obstruction and chronic pancreatitis.
Marr, Brendan; Yenumula, Panduranga
2012-01-01
Complications after laparoscopic Roux-en-Y gastric bypass surgery may be related to the type of surgical technique employed. One technique, the placement of a Roux limb stabilization suture, presumably prevents kink at the gastrojejunal anastomosis. However, it can have an adverse effect and we studied a series of cases presenting with intestinal obstruction secondary to this stitch. A retrospective review of a prospectively collected database of laparoscopic Roux-en-Y gastric bypass cases who had reoperations for Roux limb volvulus was performed at a single bariatric center by a single surgeon. Out of 199 patients who underwent laparoscopic Roux en Y gastric bypass with placement of Roux limb stabilization suture, 4 patients (2.01%) presented with Roux limb volvulus postoperatively. BMI was 45.35 ± 2.95. The postoperative time to presentation was 11 ± 10.6 months. All four patients required surgical exploration to reduce the volvulus. In all cases, the Roux limb volvulus was directly attributable to the presence of the stabilization suture. In subsequent 250 cases where this suture was eliminated, there was no volvulus of Roux limb seen. The use of a stabilization suture can result in volvulus of the Roux limb causing intestinal obstruction and this complication can be prevented by avoiding this suture.
Liu, Stanley Yung-Chuan; Guilleminault, Christian; Huon, Leh-Kiong; Yoon, Audrey
2017-08-01
A narrow maxilla with high arched palate characterizes a phenotype of obstructive sleep apnea (OSA) patients that is associated with increased nasal resistance and posterior tongue displacement. Current maxillary expansion techniques for adults are designed to correct dentofacial deformity. We describe distraction osteogenesis maxillary expansion (DOME) tailored to adult patients with OSA with narrow nasal floor and high arched palate without soft tissue redundancy. DOME is performed with placement of maxillary expanders secured by mini-implants along the midpalatal suture. This minimizes the maxillary osteotomies necessary to re-create sutural separation for reliable expansion at the nasal floor and palatal vault. We report the safety and efficacy profile of the first 20 patients at Stanford who underwent DOME.
Naldini, Gabriele; Martellucci, Jacopo; Rea, Roberto; Lucchini, Stefano; Schiano di Visconte, Michele; Caviglia, Angelo; Menconi, Claudia; Ren, Donglin; He, Ping; Mascagni, Domenico
2014-05-01
The aim of the study was to assess the safety, efficacy and feasibility of stapled transanal procedures performed by a new dedicated device, TST STARR Plus, for tailored transanal stapled surgery. All the consecutive patients admitted to eight referral centres affected by prolapses with III-IV degrees haemorrhoids or obstructed defecation syndrome (ODS) with rectocele and/or rectal intussusception that underwent stapled transanal resection with TST STARR plus were included in the present study. Haemostatic stitches for bleeding of the suture line, specimen volume, operative time, hospital stay and perioperative complications were recorded. From 1 November 2012 to 31 March 2013, 160 consecutive patients (96 females) were enrolled in the study. In 94 patients, the prolapse was over the half of the circular anal dilator (CAD). The mean duration of the procedure was 25 min. The mean resected volume of the specimen was 13.3 cm(3), the mean hospital stay was 2.2 days. In 88 patients (55%), additional stitches on the suture line were needed (mean 2.1). Suture line dehiscence was reported in four cases, with intraoperative reinforcement. Bleeding was reported in seven patients (5%). Urgency after 30 days was reported in one patient. No major complication occurred. The new device seems to be safe and effective for a tailored approach to anorectal prolapse due to haemorrhoids or obstructed defecation.
Pratt, Janey S A; Van Noord, Michael; Christison-Lagay, Emily
2007-05-01
Known complications of Roux-en-Y gastric bypass causing abdominal pain and obstructive symptoms include biliary colic, anastomotic ulcer, anastomotic stenosis, or internal hernia. This case report describes a new complication in a patient 15 months post-bypass: a bezoar at the gastrojejunal anastomosis, the nidus of which was a length of permanent suture material which had eroded through the gastric wall. We include endoscopic images of the bezoar, a review of the related gastric bypass literature, and describe the changes made in our practice as a result of this complication.
Olah, Z
1979-11-01
The present paper deals with the results of 20 eyes of experimentally operated laboratory animals, whose perforating wounds (of cornea and those of sclerocorneal region) have been suturated with a new type of absorbable synthetic suture material "Dexon" thickness being 6-0. The synthetic absorbable suture material "Dexon" is made of polyglycol acid, and it has been introduced to market by the firm Davis and Geck (U.S.A.). The inflammatory tissue reaction to the presence of the suture material "Dexon" is prominent and can by compared to the reaction to chromic resorbable suture materials (catgut or collagen). The suture material "Dexon" start to resorb in the course of the 2nd-3rd weeks after operation. The suture material "Dexon" can be used at an advantage in the operation where it is possible to cover the knots by a conjuctival lobe (in sclerocorneal region or in strabismus surgery) in this way the tendency to overgrowing of epithelial cells along the suture channels can be prevented. The "Dexon" material is sufficiently flexible and firm and has no antigenic properties, therefore it appears very prospective for ophthalmosurgery.
Suture retraction technique to prevent parent vessel obstruction following aneurysm tandem clipping.
Rayan, Tarek; Amin-Hanjani, Sepideh
2015-08-01
With large or giant aneurysms, the use of multiple tandem clips can be essential for complete obliteration of the aneurysm. One potential disadvantage, however, is the considerable cumulative weight of these clips, which may lead to kinking of the underlying parent vessels and obstruction of flow. The authors describe a simple technique to address this problem, guided by intraoperative blood flow measurements, in a patient with a ruptured near-giant 2.2 × 1.7-cm middle cerebral artery bifurcation aneurysm that was treated with the tandem clipping technique. A total of 11 clips were applied in a vertical stacked fashion. The cumulative weight of the clips caused kinking of the temporal M2 branch of the bifurcation with reduction of flow. A 4-0 Nurolon suture tie was applied to the hub of one of the clips and was tethered to the dura of the sphenoid ridge by a small mini-clip and reinforced by application of tissue sealant. The patient underwent intraoperative indocyanine green videoangiography as well as catheter angiography, which demonstrated complete aneurysmal obliteration and preservation of vessel branches. Postoperative angiography confirmed patency of the bifurcation vessels with mild vasospasm. The patient had a full recovery with no postoperative complications and was neurologically intact at her 6-month follow-up. The suture retraction technique allows a simple solution to parent vessel obstruction following aneurysm tandem clipping, in conjunction with the essential guidance provided by intraoperative flow measurements.
Kearney, C M; Buckley, C T; Jenner, F; Moissonnier, P; Brama, P A J
2014-07-01
Selection of suture material in equine surgery is often based on costs or subjective factors, such as the surgeon's personal experience, rather than objective facts. The amount of objective data available on durability of suture materials with regard to specific equine physiological conditions is limited. To evaluate the effect of various equine physiological and pathological fluids on the rate of degradation of a number of commonly used suture materials. In vitro material testing. Suture materials were exposed in vitro to physiological fluid, followed by biomechanical analysis. Three absorbable suture materials, glycolide/lactide copolymer, polyglactin 910 and polydioxanone were incubated at 37°C for 7, 14 or 28 days in phosphate-buffered saline, equine serum, equine urine and equine peritoneal fluid from an animal with peritonitis. Five strands of each suture material type were tested to failure in a materials testing machine for each time point and each incubation medium. Yield strength, strain and Young's modulus were calculated, analysed and reported. For all suture types, the incubation time had a significant effect on yield strength, percentage elongation and Young's modulus in all culture media (P<0.0001). Suture type was also shown significantly to influence changes in each of yield strength, percentage elongation and Young's modulus in all culture media (P<0.0001). While the glycolide/lactide copolymer demonstrated the highest Day 0 yield strength, it showed the most rapid degradation in all culture media. For each of the 3 material characteristics tested, polydioxanone showed the least variation across the incubation period in each culture medium. The duration of incubation and the type of fluid have significant effects on the biomechanical properties of various suture materials. These findings are important for evidence-based selection of suture material in clinical cases. © 2013 EVJ Ltd.
Jałyński, Marek; Piskorz, Łukasz; Brocki, Marian
2013-01-01
Introduction Formation of adhesions after laparoscopic hernia repair using the intra-peritoneal onlay mesh (IPOM) procedure can lead to intestinal obstruction or mesh erosion into intestinal lumen. The aims of this study included: measurement of adhesion formation with Dynamesh IPOM after laparoscopic intraperitoneal implantation, and assessment of the occurrence of isolated adhesions at the fastening sites of slowly absorbable sutures. Material and methods Twelve healthy pigs underwent laparoscopic implantation of 2 Dynamesh IPOM mesh fragments each, one was fastened with PDSII, and the other with Maxon sutures. An assessment of adhesion formation was carried out after 6 weeks and included an evaluation of surface area, hardness according to the Zhulke scale, and index values. The occurrence of isolated adhesions at slowly absorbable suture fixation points was also analyzed. Results Adhesions were noted in 83.3% of Dynamesh IPOM meshes. Adhesions covered on average 37.7% of the mesh surface with mean hardness 1.46 and index value 78.8. In groups fixed with PDS in comparison to Maxon sutures adhesions covered mean 31.6% vs. 42.5% (p = 0.62) of the mesh surface, mean hardness was 1.67 vs.1.25 (p = 0.34) and index 85.42 vs. 72.02 (p = 0.95). Conclusions The Dynamesh IPOM mesh, in spite of its anti-adhesive layer of PVDF, does not prevent the formation of adhesions. Adhesion hardness, surface area, and index values of the Dynamesh IPOM mesh are close to the mean values of these parameters for other commercially available 2-layer meshes. Slowly absorbable sutures used for fastening did not increase the risk of adhesion formation. PMID:23847671
Hennecke, Kathleen; Redeker, Joern; Kuhbier, Joern W.; Strauss, Sarah; Allmeling, Christina; Kasper, Cornelia; Reimers, Kerstin; Vogt, Peter M.
2013-01-01
Repair success for injuries to the flexor tendon in the hand is often limited by the in vivo behaviour of the suture used for repair. Common problems associated with the choice of suture material include increased risk of infection, foreign body reactions, and inappropriate mechanical responses, particularly decreases in mechanical properties over time. Improved suture materials are therefore needed. As high-performance materials with excellent tensile strength, spider silk fibres are an extremely promising candidate for use in surgical sutures. However, the mechanical behaviour of sutures comprised of individual silk fibres braided together has not been thoroughly investigated. In the present study, we characterise the maximum tensile strength, stress, strain, elastic modulus, and fatigue response of silk sutures produced using different braiding methods to investigate the influence of braiding on the tensile properties of the sutures. The mechanical properties of conventional surgical sutures are also characterised to assess whether silk offers any advantages over conventional suture materials. The results demonstrate that braiding single spider silk fibres together produces strong sutures with excellent fatigue behaviour; the braided silk sutures exhibited tensile strengths comparable to those of conventional sutures and no loss of strength over 1000 fatigue cycles. In addition, the braiding technique had a significant influence on the tensile properties of the braided silk sutures. These results suggest that braided spider silk could be suitable for use as sutures in flexor tendon repair, providing similar tensile behaviour and improved fatigue properties compared with conventional suture materials. PMID:23613793
Petrut, Bogdan; Hogea, Maximiliam; Fetica, Bogdan; Kozan, Andrei; Feflea, Dragos; Sererman, Gabriel; Goezen, Ali Serdar; Rassweiler, Jens
2013-01-01
The laparoscopic approach in urological surgery demands a high degree of skill in intracorporeal suturing and knot tying. In an effort to reduce the amount of time required to perform a suture, new materials have been developed that through selfanchorage distribute tension more evenly across the suture and also eliminate the need of knot tying. The goal of this study was to assess the in vivo tissue response to a novel material (V-Loc tm; Covidien) in comparison to established materials (Vicryl, PDS II), in the case of bladder suturing, in a rat model. The study included 48 male Wistar rats. All underwent a median abdominal incision, with a 1cm cystotomy, followed by a running suture. The suture material used was either V-Loc absorbable self anchoring thread, Vicryl threaded absorbable suture or monofilament absorbable suture. The abdominal cavity and the bladder suture were macroscopically evaluated at the rats' scheduled death at 3 and 6 weeks. The bladder wall was microscopically assessed by a pathologist, with regard to tissue reaction and suture material degradation. All rats survived the procedure, with the abdominal scar fully healed at week 2. There were no signs of infection or lithiasis during the observation. Macroscopically, at 3 weeks, the suture material was recognizable and visible in all cases, with special mention that the V-Loc thread was considerably more rigid, retaining its shape almost entirely, and provoked more adhesion of the surrounding tissue. At 6 weeks, the suture was indistinguishable in the bladder wall in the case of monofilament absorbable material, barely visible in the case of Vicryl, while the aspect of the V-Loc suture resembled the one at 3 weeks, with the material still clearly visible in the bladder wall, shape almost entirely maintained, and surrounding tissue adherence. Microscopically, at 3 weeks and 6 weeks, all bladder walls examined had regained their structure. At 3 weeks, the monofilament absorbable suture showed intense tissue reaction, with the material already in phagocytosis; at 6 weeks, no clear evidence of leftover material was observed. At 3 weeks, the Vicryl material showed moderate tissue reaction, with phagocytosis initiated between the strands of the material; at 6 weeks, the material was almost entirely absorbed, but with a clear leftover tissue reaction. In the case of the V-Loc suture, due to the hardness of the thread, the material itself could not be cut for analysis with the bladder wall, and the examination could only involve the bladder wall and marks of the thread. Thus, the tissue reaction was minimal, as was the presence of phagocytes at the suture site. The material showed little, if any, signs of absorption after 6 weeks. The materials tested all proved equally effective in suturing the bladder wall in a rat model. However, the novel barbed thread proved a consistently low in-vivo absorption rate, while maintaining its rigidity over time. More research is needed to assess the possible clinical implications of these findings.
PETRUT, BOGDAN; HOGEA, MAXIMILIAM; FETICA, BOGDAN; KOZAN, ANDREI; FEFLEA, DRAGOS; SERERMAN, GABRIEL; GOEZEN, ALI SERDAR; RASSWEILER, JENS
2013-01-01
Aim The laparoscopic approach in urological surgery demands a high degree of skill in intracorporeal suturing and knot tying. In an effort to reduce the amount of time required to perform a suture, new materials have been developed that through selfanchorage distribute tension more evenly across the suture and also eliminate the need of knot tying. The goal of this study was to assess the in vivo tissue response to a novel material (V-Loc tm; Covidien) in comparison to established materials (Vicryl, PDS II), in the case of bladder suturing, in a rat model. Methods The study included 48 male Wistar rats. All underwent a median abdominal incision, with a 1cm cystotomy, followed by a running suture. The suture material used was either V-Loc absorbable self anchoring thread, Vicryl threaded absorbable suture or monofilament absorbable suture. The abdominal cavity and the bladder suture were macroscopically evaluated at the rats’ scheduled death at 3 and 6 weeks. The bladder wall was microscopically assessed by a pathologist, with regard to tissue reaction and suture material degradation. Results All rats survived the procedure, with the abdominal scar fully healed at week 2. There were no signs of infection or lithiasis during the observation. Macroscopically, at 3 weeks, the suture material was recognizable and visible in all cases, with special mention that the V-Loc thread was considerably more rigid, retaining its shape almost entirely, and provoked more adhesion of the surrounding tissue. At 6 weeks, the suture was indistinguishable in the bladder wall in the case of monofilament absorbable material, barely visible in the case of Vicryl, while the aspect of the V-Loc suture resembled the one at 3 weeks, with the material still clearly visible in the bladder wall, shape almost entirely maintained, and surrounding tissue adherence. Microscopically, at 3 weeks and 6 weeks, all bladder walls examined had regained their structure. At 3 weeks, the monofilament absorbable suture showed intense tissue reaction, with the material already in phagocytosis; at 6 weeks, no clear evidence of leftover material was observed. At 3 weeks, the Vicryl material showed moderate tissue reaction, with phagocytosis initiated between the strands of the material; at 6 weeks, the material was almost entirely absorbed, but with a clear leftover tissue reaction. In the case of the V-Loc suture, due to the hardness of the thread, the material itself could not be cut for analysis with the bladder wall, and the examination could only involve the bladder wall and marks of the thread. Thus, the tissue reaction was minimal, as was the presence of phagocytes at the suture site. The material showed little, if any, signs of absorption after 6 weeks. Conclusion The materials tested all proved equally effective in suturing the bladder wall in a rat model. However, the novel barbed thread proved a consistently low in-vivo absorption rate, while maintaining its rigidity over time. More research is needed to assess the possible clinical implications of these findings. PMID:26527981
Effect of human pancreatic juice and bile on the tensile strength of suture materials.
Muftuoglu, M A Tolga; Ozkan, Erkan; Saglam, Abdullah
2004-08-01
Several suture materials are used for pancreatojejunal anastomosis. In this study, we tested the durability of these suture materials in human pancreatic juice and bile. Plain and chromic catgut, polyglactin 910, polyglycolic acid, polydioxanone, polypropylene, and silk sutures were incubated in pancreatic juice and bile that was collected from patients. Fifteen samples of each type of suture material were placed in human juices for 1, 3, and 7 days. Tensile strengths were measured with a tensionmeter. Plain and chromic catgut disintegrated in pancreatic juice and pancreatic juice plus bile mixture. Polyglycolic acid and polyglactin 910 suture materials were vulnerable to pancreatic juice within 7 days. Polydioxanone retained most of its initial strength in pancreatic juice and bile. Polypropylene and silk retained 84% and 92% of their initial strength, respectively. We found that polidioxanone was the strongest suture material in pancreatic juice.
In Vitro Tensile Strength Study on Suturing Technique and Material.
González-Barnadas, Albert; Camps-Font, Octavi; Espanya-Grifoll, Dunia; España-Tost, Antoni; Figueiredo, Rui; Valmaseda-Castellón, Eduard
2017-06-01
Suture technique and materials are important in preventing complications such as wound dehiscences. The purpose of this study was to determine the tensile strength of different suturing techniques, comparing several materials with different diameters. One hundred sixty sutures were performed using silk, e-PTFE, and 2 types of polyamide (monofilament and Supramid). Ten simple, 10 horizontal mattress, and 10 combinations of the two stitches were performed with 4-0 gauge of each material. Additionally, 10 simple sutures were performed with the 5-0 gauge of each material. The maximum tensile force resisted by each suture was recorded. When 5 mm of traction was applied, the polyamide monofilament resisted significantly better without untying or breaking compared with Supramid or silk, while the e-PTFE was superior to all the others. However, the force when e-PTFE 4-0 sutures untied or broke was lower than for either type of polyamide. The combined technique withstood a significantly higher tensile force before unknotting or breaking than did the simple and mattress stitches. The 5-0 gauges of silk and both types of polyamide showed lower tensile strengths than the 4-0 materials. Among the 5-0 sutures, Supramid showed a higher tensile strength than silk. The combined suture technique possessed greater tensile strength than did a simple or a horizontal mattress suture, and e-PTFE 4-0 withstood more traction without untying or breaking than did all the other materials, although at a lower tensile force. With the exception of e-PTFE, 4-0 sutures had greater tensile strength than did 5-0 sutures.
Biocompatibility and strength properties of nitinol shape memory alloy suture in rabbit tendon.
Kujala, Sauli; Pajala, Ari; Kallioinen, Matti; Pramila, Antti; Tuukkanen, Juha; Ryhänen, Jorma
2004-01-01
Nitinol (NiTi) is a promising new tendon suture material with good strength, easy handling and good super-elastic properties. NiTi sutures were implanted for biocompatibility testing into the right medial gastrocnemius tendon in 15 rabbits for 2, 6 and 12 weeks. Additional sutures were implanted in subcutaneous tissue for strength measurements in order to determine the effect of implantation on strength properties of NiTi suture material. Braided polyester sutures (Ethibond) of approximately the same diameter were used as control. Encapsulating membrane formation around the sutures was minimal in the case of both materials. The breaking load of NiTi was significantly greater compared to braided polyester. Implantation did not affect the strength properties of either material.
Suture Products and Techniques: What to Use, Where, and Why.
Regula, Christie G; Yag-Howard, Cyndi
2015-10-01
There are an increasing number of wound closure materials and suturing techniques described in the dermatologic and surgery literature. A dermatologic surgeon's familiarity with these materials and techniques is important to supplement his or her already established practices and improve surgical outcomes. To perform a thorough literature review of wound closure materials (sutures, tissue adhesives, surgical tape, and staples) and suturing techniques and to outline how and when to use them. A literature review was conducted using PubMed and other online search engines. Keywords searched included suture, tissue adhesive, tissue glue, surgical tape, staples, dermatologic suturing, and suturing techniques. Numerous articles outline the utility of various sutures, surgical adhesives, surgical tape, and staples in dermatologic surgery. In addition, there are various articles describing classic and novel suturing techniques along with their specific uses in cutaneous surgery. Numerous factors must be considered when choosing a wound closure material and suturing technique. These include wound tension, desire for wound edge eversion/inversion, desired hemostasis, repair type, patient's ability to care for the wound and return for suture removal, skin integrity, and wound location. Careful consideration of these factors and proper execution of suturing techniques can lead to excellent cosmetic results.
Lambertz, Andreas; Schröder, Kai Michael; Schöb, Dominik Stefan; Binnebösel, Marcel; Anurov, Michael; Klinge, Uwe; Neumann, Ulf Peter; Klink, Christian Daniel
2015-01-01
Biocompatibility and tissue integration of a surgical suture are decisive factors for wound healing and therefore for the success of sutures. The optimal suture material is still under discussion. Polyvinylidene fluoride (PVDF) is described to have superior properties of biocompatibility and is therefore frequently used as a mesh component. Only little information is available about its use as a suture material. The aim of this study was to evaluate the biocompatibility of PVDF as a suture material in comparison to 5 different established sutures in a rat model. In 30 male rats, a monofilamental PVDF suture (Resopren®) and 5 established control suture materials [polyester (Miralene®), polytetrafluoroethylene (Gore®), poliglecaprone (Monocryl®), polydioxanone (Monoplus®), polyglactin 910 (Vicryl®), USP size 3-0] were placed in the subcutaneous layer of the abdominal wall without knot or tension. After 3, 7 or 21 days, the abdominal walls were explanted for histopathological and immunohistochemical investigation with special regard to the size and quality of foreign body granuloma and the length of the comet tail-like infiltrate (CTI). The PVDF sutures showed the smallest size of foreign body granuloma (60 ± 14 µm) and the smallest CTI length (343 ± 60 µm) of all polymers after 21 days. Only PVDF (Resopren) and polydioxanone (Monoplus) showed a significant collagen I/III ratio increase between days 3 and 21 (p = 0.009 and p = 0.016). The quality of foreign body reaction regarding inflammation, proliferation and fibrotic remodeling was similar between all suture materials. Our data indicate that monofilamental PVDF sutures show a favorable foreign body reaction with small granuloma sizes and CTI length in comparison to established sutures. Its use as a suture material in general surgery could therefore be extended in the future. To reinforce these findings, further clinical studies need to be conducted. 2015 S. Karger AG, Basel.
Advances in Suture Material for Obstetric and Gynecologic Surgery
Greenberg, James A; Clark, Rachel M
2009-01-01
Despite millennia of experience with wound closure biomaterials, no study or surgeon has yet identified the perfect suture for all situations. Tissue characteristics, tensile strength, reactivity, absorption rates, and handling properties should be taken into account when selecting a wound closure suture. This review discusses the wound healing process and the biomechanical properties of currently available suture materials to better understand how to choose suture material in obstetrics and gynecology. PMID:19826572
Early orthodontic management of Crouzon Syndrome: a case report.
Hlongwa, P
2009-03-01
Crouzon Syndrome is an autosomal dominant disorder with complete penetrance and variable expressivity. Described by a French neurosurgeon in 1912, it is a rare genetic disorder. Crouzon syndrome is caused by mutation in the fibroblast growth factor receptor 2 (FGFR2) gene. The disease is characterized by premature synostosis of coronal and sagittal sutures which begins in the first year of life. Once the sutures become closed, growth potential to those sutures is restricted. However, multiple sutural synostoses frequently extend to premature fusion of skull base causing midfacial hypoplasia, shallow orbit, maxillary hypoplasia and occasional upper airway obstruction.The case of a 7-year-old South African black boy with Crouzon Syndrome is presented. He presented with characteristic triad of cranial deformity, maxillary hypoplasia and exophthalmos. The clinical, cephalometric features and initial orthodontic management of this patient are discussed as part of multidisciplinary management.
Yates, Robert B; Hinojosa, Marcelo W; Wright, Andrew S; Pellegrini, Carlos A; Oelschlager, Brant K
2015-05-01
Operative repair of obstructive gastric volvulus is challenging. In high-operative risk patients with obstructive gastric volvulus, we perform laparoscopic reduction of gastric volvulus and anterior abdominal wall sutured gastropexy. This case series reports our experience with this operation. We reviewed the charts of all patients who presented with obstructive gastric volvulus and underwent laparoscopic gastropexy between 2007 and 2013. Eleven patients underwent laparoscopic gastropexy. Median age was 83 years (50 to 92). Six patients presented with chronic obstruction; 5 presented with acute obstruction. Median postoperative hospitalization was 2 days (1 to 39). Two patients required reoperation for displaced gastrostomy tubes. At median follow-up of 3 months (2 weeks to 57 months), all patients remained free of gastric obstructive symptoms and recurrent episodes of volvulus. Only 1 patient received nutrition via gastrostomy tube. Laparoscopic gastropexy can treat obstructed gastric volvulus in highoperative risk patients. Because of associated morbidity, gastrostomy tubes should be placed selectively. Copyright © 2015 Elsevier Inc. All rights reserved.
Reversible surgical model of biliary inflammation and obstructive jaundice in mice.
Kirkland, Jacob G; Godfrey, Cody B; Garrett, Ryan; Kakar, Sanjay; Yeh, Benjamin M; Corvera, Carlos U
2010-12-01
Common bile duct (CBD) ligation is used in animal models to induce biliary inflammation, fibrosis, and cholestatic liver injury, but results in a high early postoperative mortality rate, probably from traumatic pancreatitis. We modified the CBD ligation model in mice by placing a small metal clip across the lower end of the CBD. To reverse biliary obstruction, a suture was incorporated within the clip during its placement. The suture and clip were removed on postoperative d 5 or 10 for biliary decompression. After 5 d of biliary obstruction, the gallbladder showed an 8-fold increase in wall thickness and a 17-fold increase in tissue myeloperoxidase activity. Markedly elevated serum levels of alkaline phosphatase and bilirubin indicated injury to the biliary epithelium and hepatocytes. Early postoperative (d 0-2) survival was 100% and later (d 3-5) survival was 85% (n=54 mice). We successfully reversed biliary obstruction in 20 mice (37%). Overall survival after reversal was 70%. In surviving mice, biliary decompression was complete, inflammation was reduced, and jaundice resolved. Histologic features confirmed reduced epithelial damage, edema, and neutrophil infiltration. Our technique minimized postoperative death, maintained an effective inflammatory response, and was easily reversible without requiring repeat laparotomy. This reversible model can be used to further define molecular mechanisms of biliary inflammation, fibrosis, and liver injury in genetically altered mice. Copyright © 2010. Published by Elsevier Inc.
Suture versus tack fixation of mesh in laparoscopic umbilical hernia repair.
Kitamura, Riley K; Choi, Jacqueline; Lynn, Elizabeth; Divino, Celia M
2013-01-01
Mesh fixation in laparoscopic umbilical hernia repair is poorly studied. We compared postoperative outcomes of laparoscopic umbilical hernia repair in suture versus tack mesh fixation. Patients who underwent laparoscopic umbilical hernia repair were separated by method of mesh fixation: sutures versus primarily tacks. Medical history and follow-up data were collected through medical records. The primary outcome of this study was the recurrence rates of hernias. Postoperative major and minor complications, such as surgical site infection, small-bowel obstruction, and seroma formation, were regarded as secondary outcomes. Additionally, a telephone interview was conducted to assess postoperative pain, recovery time, and overall patient satisfaction. Eighty-six patients were identified: 33 in the suture group and 53 in the tacks group. The number of emergent cases was increased in the tacks group (6 vs 0; P = .022). Mean follow-up time was 2.7 years for both groups. Documented postoperative follow-up was obtained in 29 (90%) suture group and 31 (58%) tacks group patients. Hernia recurrence occurred in 3 and 2 patients in the sutures and tacks groups, respectively (P was not significant). No differences were found in secondary outcomes, including subjective outcomes from telephone interviews, between groups. There are no differences in postoperative complication rates in suture versus tack mesh fixation in laparoscopic umbilical hernia repair.
Nickel-Titanium Wire as Suture Material: A New Technique for the Fixation of Skin.
Li, Haidong; Song, Tao
2018-01-29
To introduce nickel-titanium wire as suture material for closure of incisions in cleft lip procedures. Closure of skin incisions using nickel-titanium wire as suture material, with postoperative follow-up wound evaluation. There was excellent patient satisfaction and good cosmetic outcome. Nickel-titanium wire is an excellent alternative for suture closure of cleft lip surgical incisions.
Effect of human urine on the tensile strength of sutures used for hypospadias surgery.
Kerstein, Ryan L; Sedaghati, Tina; Seifalian, Alexander M; Kang, Norbert
2013-06-01
Hypospadias is the most common congenital condition affecting between 1 in 250 and 300 live births. Even in experienced hands, surgery to repair this congenital defect can have a high complication rate. Wound dehiscence is reported to occur in 5% and fistula formation in 6%-40% depending on technique. The choice of suture material has been shown to affect the complication rate although there is (currently) no consensus about the best suture material to use. Ideally, the sutures used for urethroplasty should be absorbable while maintaining sufficient mechanical strength to support the wounds until they are self-supporting and able to resist urinary flow. Previous studies have compared the effects of human urine on different suture materials especially catgut. However, catgut is now banned in Europe. Our study examined the tensile and breaking strength as well as rate of degradation for four types of absorbable suture now commonly used for hypospadias repairs in the UK. We examined the effect of prolonged storage (up to 27 days) in human urine on 6/0 gauge Vicryl, Vicryl Rapide, Monocryl and polydioxanone (PDS) sutures. These four suture materials are commonly used by the senior plastic consultant surgeon (NK) for hypospadias repairs. 50 mm sections of these suture materials were stored in either urine or saline as control. At specified time points, each suture was placed in a uniaxial load testing machine to assess the stress-strain profile and the mechanical load required to break the suture was measured. Exposure to urine reduced the tensile and breaking strength of all the suture materials tested. PDS demonstrated the greatest resilience. Vicryl Rapide was the weakest suture and degraded completely by day 6. Vicryl and Monocryl had similar degradation profiles, but Vicryl retained more of its tensile strength for longer. There is a balance to be struck between the duration that a suture material must remain in any surgical wound and the risk that it causes foreign body effects. The results of this study suggest that Vicryl has the best characteristics for urethroplasty of the four suture materials tested. Copyright © 2013 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Trost, Landon; Parekattil, Sijo; Wang, Julie; Hellstrom, Wayne J G
2014-04-01
Various surgical approaches have been described to manage iatrogenic inguinal vasal obstruction, including open microscopic, laparoscopic and robot-assisted techniques. The open and laparoscopic approaches are often limited in cases of extensive inguinal obstruction or inadequate intra-abdominal vasal length. The robotic approach offers novel opportunities to the operating surgeon, including performing microsurgical anastomoses in traditionally challenging locations. To our knowledge we describe the first intracorporeal robot-assisted, microsurgical vasovasostomy for iatrogenic vasal obstruction not amenable to standard microscopic repair. Bilateral intracorporeal robot-assisted microsurgical vasovasostomy was performed. The proximal vasa were transected and obstruction of the distal segments was confirmed. After docking the robot the intracorporeal regions of the vasa were transected at the internal ring. The proximal vasal segments were passed intracorporeally and approximated with 5-zero polypropylene sutures. A standard 2-layer anastomosis was performed intracorporeally using 10-zero/9-zero sutures. Total operative time was 278 minutes. No intraoperative or postoperative complications were noted. Semen analysis 8 weeks after the procedure demonstrated a total volume of 5.4 cc, 8.4 × 10(6) sperm per ml, 45.4 × 10(6) total sperm and 16% motility, consistent with a successful result. To our knowledge this represents the first reported case of intracorporeal outpatient vasovasostomy. These results demonstrate the feasibility of the procedure and highlight unique aspects of the robotic approach, which may offer advantages over the traditional microscope in select cases. Copyright © 2014 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
Failure of mesenteric defect closure after Roux-en-Y gastric bypass.
Hope, William W; Sing, Ronald F; Chen, Albert Y; Lincourt, Amy E; Gersin, Keith S; Kuwada, Timothy S; Heniford, B Todd
2010-01-01
Bowel obstructions following Roux-en-Y gastric bypass (RYGB) are a significant issue often caused by internal herniation. Controversy continues as to whether mesenteric defect closure is necessary to decrease the incidence of internal hernias after RYGB. Our purpose was to evaluate the effectiveness of closing the mesenteric defect at the jejunojejunostomy in patients who underwent RYGB by examining this potential space at reoperation for any reason. We retrospectively reviewed medical records of patients undergoing surgery after RYGB from August 1999 to October 2008 to determine the status of the mesentery at the jejunojejunostomy. Eighteen patients underwent surgery 2 to 19 months after open (n=8) or laparoscopic (n=10) RYGB. All patients had documented suture closure of their jejunojejunostomy at the time of RYGB. Permanent (n=12) or absorbable (n=6) sutures were used for closures. Patients lost 23.6 kg to 62.1 kg before a reoperation was required for a ventral hernia (n=8), cholecystectomy (n=4), abdominal pain (n=4), or small bowel obstruction (n=2). Fifteen of the 18 patients had open mesenteric defects at the jejunojejunostomy despite previous closure; none were the cause for reoperation. Routine suture closure of mesenteric defects after RYGB may not be an effective permanent closure likely due to the extensive fat loss and weight loss within the mesentery.
Kirsch, A J; Chang, D T; Kayton, M L; Libutti, S K; Connor, J P; Hensle, T W
1996-01-01
Tissue welding using laser-activated protein solders may soon become an alternative to sutured tissue approximation. In most cases, approximating sutures are used both to align tissue edges and provide added tensile strength. Collateral thermal injury, however, may cause disruption of tissue alignment and weaken the tensile strength of sutures. The objective of this study was to evaluate the effect of laser welding on the tensile strength of suture materials used in urologic surgery. Eleven types of sutures were exposed to diode laser energy (power density = 15.9 W/cm2) for 10, 30, and 60 seconds. Each suture was compared with and without the addition of dye-enhanced albumin-based solder. After exposure, each suture material was strained (2"/min) until ultimate breakage on a tensometer and compared to untreated sutures using ANOVA. The strength of undyed sutures were not significantly affected; however, violet and green-dyed sutures were in general weakened by laser exposure in the presence of dye-enhanced glue. Laser activation of the smallest caliber, dyed sutures (7-0) in the presence of glue caused the most significant loss of tensile strength of all sutures tested. These results indicate that the thermal effects of laser welding using our technique decrease the tensile strength of dyed sutures. A thermally resistant suture material (undyed or clear) may prevent disruption of wounds closed by laser welding techniques.
Regadas, F S P; Regadas, S M M; Rodrigues, L V; Misici, R; Silva, F R; Regadas Filho, F S P
2005-04-01
We present a new surgical stapling technique for treatment of rectocele when associated with internal mucosal prolapse or haemorrhoids using only one circular mechanical stapler. Eight female patients, mean age 53 years (range, 42-70), complaining of obstructed defecation with vaginal digitation because of rectocele associated with internal mucosal prolapse underwent transanal repair of rectocele and rectal mucosectomy using one circular stapler between April and July 2004. A running horizontal mattress suture was placed through the base of the rectocele including mucosa, submucosa and the muscle layer of the whole anterior anorectal junction wall. The prolapsed mucosa and the muscular layer were then excised with an electrical scapel. A continuous pursestring rectal mucosa suture was placed 0.5 cm before the previous anterior mucosa and muscle layers resected wound, including the anorectal junction wall which was kept separate from the posterior vaginal wall by a Babcock forceps. Posteriorly, the pursestring suture included only mucosal and submucosal layers. The stapled suture was positioned between normal anterior rectal wall and the anal canal, 0.5 cm above the pectinate line. The stapler was then closed, fired and withdrawn. One patient complained of a perianal hematoma on the seventh postoperative day, requiring surgical excision. Postoperative defecography showed correction of the rectocele and outlet obstruction disappeared in all patients. This novel combined manual-stapled technique for rectocele and rectal internal mucosal prolapse seems to be a safe procedure and the preliminary results are encouraging. Further investigations have to be performed to assess long-term outcome in a larger number of patients.
Evaluation of tensile strength of surgical synthetic absorbable suture materials: an in vitro study
Ranganath, V.; Nichani, Ashish Sham
2013-01-01
Purpose The purpose of this study was to evaluate the tensile strength of surgical synthetic absorbable sutures over a period of 14 days under simulated oral conditions. Methods Three suture materials (polyglycolic acid [PGA], polyglactin [PG] 910, and poly (glycolide-co-є-caprolactone) [PGC]) were used in 4-0 and 5-0 gauges. 210 suture samples (35 of each material and gauge) were used. All of the samples were tested preimmersion and 1 hour and 1, 3, 7, 10, and 14 days postimmersion. The tensile strength of each suture material and gauge was assessed. The point of breakage and the resorption pattern of the sutures were also assessed. Results During the first 24 hours of immersion, all 4-0 and 5-0 samples of PGA, PG 910, and PGC maintained their initial tensile strength. At baseline (preimmersion), there was a statistically significant (P<0.001) difference in the tensile strengths between the 4-0 and 5-0 gauge of PGA, PG 910, and PGC. PGA 4-0 showed the highest tensile strength until day 10. At 7 days, all the 4-0 sutures of the three materials had maintained their tensile strength with PGA 4-0 having significantly greater (P=0.003) tensile strength compared to PG. Conclusions 4-0 sutures are stronger and have greater tensile strength than 5-0 sutures. The PGA 4-0 suture showed the highest tensile strength at the end of day 10. PMID:23837127
Zhou, Feng; Fang, Zhen-Qiang; Zhang, Yuan-Ning; Chen, Wei; Liu, Yong-Liang; Ye, Gang
2010-08-01
To compare the mechanical and sutured ureteroneocystostomy in a canine model. In 18 dogs, extravesical ureteroneocystostomy on 1 side was randomly assigned to end-to-side anastomosis performed with a titanium ring-pin stapler or interrupted absorbable sutures. To create the antireflux tunnel, the longitudinal line of the muscle layer was closed over the implanted ureter with titanium clips or sutures. At 3 months postoperatively, renal ultrasonography, intravenous urography, ascending cystography, the Whitaker test, and the macroscopic and microscopic results were assessed. The ureteroneocystostomy with the ring pin stapler and the antireflux tunnel construction with titanium clips had a 100% technical success rate. Compared with manual suturing anastomosis, the suture-free technique took a significantly shorter time and resulted in slightly, but not significantly, less ureteral obstruction after 3 months. One dog in group 2 had evidence of ureteral dilation and hydronephrosis compared with the normal contralateral side. No signs of stone formation, urinary cyst, or fistulas were found after either closure method. None of the 18 dogs demonstrated vesicoureteral reflux. Histologic examination showed no signs of acute inflammation or marked fibrosis in any of the 18 specimens. Moreover, the intrapelvic pressure in group 1 was approximately similar to that of the normal contralateral side. Ureteroneocystostomy performed with a titanium ring-pin stapler is feasible and faster than using conventional sutures. This suture-free technique is simple and safe, with possibly lower complication rates than a nonstented suture technique. Additional studies with a longer follow-up duration are needed to confirm these results. Copyright 2010. Published by Elsevier Inc.
Suture material in bladder surgery: a comparison of polydioxanone, polyglactin, and chromic catgut.
Stewart, D W; Buffington, P J; Wacksman, J
1990-06-01
A comparison of polydioxanone, polyglactin, and chromic catgut suture was performed in 120 rat bladders studying propensity for infection, degree of inflammation, calculogenic potential, changes in urine pH, and suture absorption. None of the sutures predisposed to infection and there was wide variability but no correlation in urine pH. Although initially the polydioxanone incited a greater inflammatory response, by six months all three sutures were similar. The absorption of polydioxanone was slower than chromic catgut suture, but similar to the absorption of polyglactin. There was no significant difference in calculogenic potential between the suture materials tested over a six-month period. Based on this study in rats, polydioxanone suture would appear to be equal to catgut and polyglactin suture in bladder surgery.
Sunay, Melih; Karakan, Tolga; Aydın, Arif; Koca, Gökhan; Börcek, Pınar; Öğüş, Elmas
2015-10-01
We assessed the nephroprotective effects of montelukast sodium and N-acetylcysteine on secondary renal damage due to unilateral ureteral obstruction in a rat model. In this study 30 Wistar albino male rats were randomized into 3 groups, including placebo, N-acetylcysteine and montelukast sodium. Three rats served as the control group. The left ureter of the rats was sutured with 4-zero polyglactin sutures. Medications were given 3 days before obstruction and continued for 15 days. Dimercaptosuccinic acid renal scintigraphy was performed before obstruction and on day 15. Rats were sacrificed on day 15 and histopathological examinations were done. We biochemically assessed oxidative stress markers (myeloperoxidase and malondialdehyde), sulfhydryl and total nitrite for lipid peroxidation, oxidative protein damage and antioxidant levels, respectively. On pathological examination inflammation and tubular epithelial damage in the N-acetylcysteine and montelukast sodium groups were less than in the placebo group (p <0.05). No difference was seen in normal kidneys. Myeloperoxidase, malondialdehyde and total nitrite levels in the N-acetylcysteine group, and myeloperoxidase and malondialdehyde levels in the montelukast sodium group were lower than in the placebo group (p <0.05). No statistical difference was seen in sulfhydryl levels (p >0.05) or among the N-acetylcysteine, montelukast sodium and placebo groups on scintigraphy (p >0.05). No pathological, chemical and scintigraphic differences were seen among the N-acetylcysteine, montelukast sodium and sham treated groups (p >0.05). N-acetylcysteine and montelukast sodium have a protective effect against obstructive damage of the kidney. However, further investigations are needed. Copyright © 2015 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
The history and evolution of sutures in pelvic surgery
Muffly, Tyler M; Tizzano, Anthony P; Walters, Mark D
2011-01-01
Summary The purpose of the study is to review the history and innovations of sutures used in pelvic surgery. Based on a review of the literature using electronic- and hand-searched databases we identified appropriate articles and gynaecology surgical textbooks regarding suture for wound closure. The first documented uses of suture are explored and then the article focuses on the use of knotted materials in pelvic surgery. The development of suture of natural materials is followed chronologically until the present time where synthetic suture is implanted during countless surgeries every day. This millennial history of suture contains an appreciation of the early work of Susruta, Celsus, Paré and Lister, including a survey of some significant developments of suture methods over the last 100 years. Most surgeons know little about the history and science of sutures. A retrospective view of suture is critical to the appreciation of the current work and development of this common tool. PMID:21357979
The history and evolution of sutures in pelvic surgery.
Muffly, Tyler M; Tizzano, Anthony P; Walters, Mark D
2011-03-01
The purpose of the study is to review the history and innovations of sutures used in pelvic surgery. Based on a review of the literature using electronic- and hand-searched databases we identified appropriate articles and gynaecology surgical textbooks regarding suture for wound closure. The first documented uses of suture are explored and then the article focuses on the use of knotted materials in pelvic surgery. The development of suture of natural materials is followed chronologically until the present time where synthetic suture is implanted during countless surgeries every day. This millennial history of suture contains an appreciation of the early work of Susruta, Celsus, Paré and Lister, including a survey of some significant developments of suture methods over the last 100 years. Most surgeons know little about the history and science of sutures. A retrospective view of suture is critical to the appreciation of the current work and development of this common tool.
Multispectral tissue characterization for intestinal anastomosis optimization.
Cha, Jaepyeong; Shademan, Azad; Le, Hanh N D; Decker, Ryan; Kim, Peter C W; Kang, Jin U; Krieger, Axel
2015-10-01
Intestinal anastomosis is a surgical procedure that restores bowel continuity after surgical resection to treat intestinal malignancy, inflammation, or obstruction. Despite the routine nature of intestinal anastomosis procedures, the rate of complications is high. Standard visual inspection cannot distinguish the tissue subsurface and small changes in spectral characteristics of the tissue, so existing tissue anastomosis techniques that rely on human vision to guide suturing could lead to problems such as bleeding and leakage from suturing sites. We present a proof-of-concept study using a portable multispectral imaging (MSI) platform for tissue characterization and preoperative surgical planning in intestinal anastomosis. The platform is composed of a fiber ring light-guided MSI system coupled with polarizers and image analysis software. The system is tested on ex vivo porcine intestine tissue, and we demonstrate the feasibility of identifying optimal regions for suture placement.
Multispectral tissue characterization for intestinal anastomosis optimization
Cha, Jaepyeong; Shademan, Azad; Le, Hanh N. D.; Decker, Ryan; Kim, Peter C. W.; Kang, Jin U.; Krieger, Axel
2015-01-01
Abstract. Intestinal anastomosis is a surgical procedure that restores bowel continuity after surgical resection to treat intestinal malignancy, inflammation, or obstruction. Despite the routine nature of intestinal anastomosis procedures, the rate of complications is high. Standard visual inspection cannot distinguish the tissue subsurface and small changes in spectral characteristics of the tissue, so existing tissue anastomosis techniques that rely on human vision to guide suturing could lead to problems such as bleeding and leakage from suturing sites. We present a proof-of-concept study using a portable multispectral imaging (MSI) platform for tissue characterization and preoperative surgical planning in intestinal anastomosis. The platform is composed of a fiber ring light-guided MSI system coupled with polarizers and image analysis software. The system is tested on ex vivo porcine intestine tissue, and we demonstrate the feasibility of identifying optimal regions for suture placement. PMID:26440616
Abbi, Gaurav; Espinoza, Luis; Odell, Timothy; Mahar, Andrew; Pedowitz, Robert
2006-01-01
To compare a standard suture material with a newer material using multiple arthroscopic knot configurations and to evaluate the biomechanical performance of a new sliding-locking knot compared with 4 surgical standards. Controlled laboratory study. Five knots were evaluated (Weston, Tennessee, Duncan, SMC, and the new San Diego knot) using 2 suture materials, No. 2 Ethibond (Ethicon, Somerville, NJ) or No. 2 Fiberwire (Arthrex, Naples, FL). Eight samples were tested for each knot-suture configuration. Samples were pretensioned to 10 N and then loaded from 10 to 45 N for 1,000 cycles. Intact knots were loaded to failure. Fiberwire had significantly higher load-to-failure (276 +/- 24 N) compared with Ethibond (111 +/- 13 N) (P < .001), although there was no significant difference as a function of knot configuration. Of the 40 Fiberwire knots, 3 failed by early slippage during cyclic loading and 8 slipped at very low tension during load-to-failure. None of the Ethibond knots and none of the San Diego knots failed by early slippage. Surface characteristics and suture construction affect the tendency for knot slippage. Surgeons should understand the impact of handling characteristics, frictional properties, and ultimate failure load when selecting suture materials and knots for arthroscopic repair.
A Common Bile Duct Stone formed by Suture Material after Open Cholecystectomy
Kim, Kook-Hyun; Jang, Byung-Ik
2007-01-01
The use of non-absorbable suture materials for cystic duct ligation after cholecystectomy can expose patients to the risk of recurrent stone formation in the common bile duct (CBD). However, in Korea suture materials have rarely been found to act as a nidus for common bile duct calculus formation. Recently, we experienced a case in which suture material, that had migrated from a previous cholecystectomy site into the CBD, probably served as a nidus for common bile duct stone formation. The stone was confirmed by endoscopic retrograde cholangiopancreatography (ERCP) and removed successfully using a basket. The authors report a case of surgical suture migration and discuss its subsequent role as a stone forming nucleus within the CBD in a patient who underwent open cholecystectomy; and include a review of the literature. PMID:18309688
Ağır, İsmail; Aytekin, Mahmut Nedim; Başçı, Onur; Çaypınar, Barış; Erol, Bülent
2014-01-01
Background: Two main factors determine the strength of tendon repair; the tensile strength of material and the gripping capacity of a suture configuration. Different repair techniques and suture materials were developed to increase the strength of repairs but none of techniques and suture materials seem to provide enough tensile strength with safety margins for early active mobilization. In order to overcome this problem tendon suturing implants are being developed. We designed two different suturing implants. The aim of this study was to measure tendon-holding capacities of these implants biomechanically and to compare them with frequently used suture techniques Materials and Methods: In this study we used 64 sheep flexor digitorum profundus tendons. Four study groups were formed and each group had 16 tendons. We applied model 1 and model 2 implant to the first 2 groups and Bunnell and locking-loop techniques to the 3rd and 4th groups respectively by using 5 Ticron sutures. Results: In 13 tendons in group 1 and 15 tendons in group 2 and in all tendons in group 3 and 4, implants and sutures pulled out of the tendon in longitudinal axis at the point of maximum load. The mean tensile strengths were the largest in group 1 and smallest in group 3. Conclusion: In conclusion, the new stainless steel tendon suturing implants applied from outside the tendons using steel wires enable a biomechanically stronger repair with less tendon trauma when compared to previously developed tendon repair implants and the traditional suturing techniques. PMID:25067965
Mudgil, A V; To, K W; Balachandran, R M; Janigian, R H; Tsiaras, W G
1999-01-01
To determine the optimal wavelength for subconjunctival laser suture lysis. 130 black monofilament 10-0 nylon sutures were sewn subconjunctivally into the bare sclera of enucleated rabbit globes. The lowest energy levels facilitating laser suture lysis were determined for the argon green (514.5 NM), argon blue-green (488.0 NM, 514.5 NM), and krypton red (647.1 NM) wavelengths. In addition, absorption spectroscopy was performed on the suture material and conjunctiva using the Perkin Elmer W/VIS Lambda 2 spectrometer. Krypton red produced the fewest buttonhole defects, and it was also the most efficient energy source for suture lysis (P = 0.0001) under nontenectomized conjunctiva. Absorbance spectra studies revealed peak absorbance at 628 NM for the 10-0 nylon suture material. Based on animal and absorption spectroscopy studies, krypton red may be a safer and more efficient wavelength for subconjunctival laser suture lysis.
Antibacterial Surgical Silk Sutures Using a High-Performance Slow-Release Carrier Coating System.
Chen, Xiaojie; Hou, Dandan; Wang, Lu; Zhang, Qian; Zou, Jiahan; Sun, Gang
2015-10-14
Sutures are a vital part for surgical operation, and suture-associated surgical site infections are an important issue of postoperative care. Antibacterial sutures have been proved to reduce challenging complications caused by bacterial infections. In recent decades, triclosan-free sutures have been on their way to commercialization. Alternative antibacterial substances are becoming relevant to processing surgical suture materials. Most of the antibacterial substances are loaded directly on sutures by dipping or coating methods. The aim of this study was to optimize novel antibacterial braided silk sutures based on levofloxacin hydrochloride and poly(ε-caprolactone) by two different processing sequences, to achieve suture materials with slow-release antibacterial efficacy and ideal physical and handling properties. Silk strands were processed into sutures on a circular braiding machine, and antibacterial treatment was introduced alternatively before or after braiding by two-dipping-two-rolling method (M1 group and M2 group). The antibacterial activity and durability against Staphylococcus aureus and Escherichia coli were tested. Drug release profiles were measured in phosphate buffer with different pH values, and release kinetics model was built to analyze the sustained drug release mechanism between the interface of biomaterials and the in vitro aqueous environment. Knot-pull tensile strength, thread-to-thread friction, and bending stiffness were determined to evaluate physical and handling properties of sutures. All coated sutures showed continuous antibacterial efficacy and slow drug release features for more than 5 days. Besides, treated sutures fulfilled U.S. Pharmacopoeia required knot-pull tensile strength. The thread-to-thread friction and bending stiffness for the M1 group changed slightly when compared with those of uncoated ones. However, physical and handling characteristics of the M2 group tend to approach those of monofilament ones. The novel suture showed acceptable in vitro cytotoxicity according to ISO 10993-5. Generally speaking, all coated sutures show potential in acting as antibacterial suture materials, and M1 group is proved to have a higher prospect for clinical applications.
Characterization of craniofacial sutures using the finite element method.
Maloul, Asmaa; Fialkov, Jeffrey; Wagner, Diane; Whyne, Cari M
2014-01-03
Characterizing the biomechanical behavior of sutures in the human craniofacial skeleton (CFS) is essential to understand the global impact of these articulations on load transmission, but is challenging due to the complexity of their interdigitated morphology, the multidirectional loading they are exposed to and the lack of well-defined suture material properties. This study aimed to quantify the impact of morphological features, direction of loading and suture material properties on the mechanical behavior of sutures and surrounding bone in the CFS. Thirty-six idealized finite element (FE) models were developed. One additional specimen-specific FE model was developed based on the morphology obtained from a µCT scan to represent the morphological complexity inherent in CFS sutures. Outcome variables of strain energy (SE) and von Mises stress (σvm) were evaluated to characterize the sutures' biomechanical behavior. Loading direction was found to impact the relationship between SE and interdigitation index and yielded varied patterns of σvm in both the suture and surrounding bone. Adding bone connectivity reduced suture strain energy and altered the σvm distribution. Incorporating transversely isotropic material properties was found to reduce SE, but had little impact on stress patterns. High-resolution µCT scanning of the suture revealed a complex morphology with areas of high and low interdigitations. The specimen specific suture model results were reflective of SE absorption and σvm distribution patterns consistent with the simplified FE results. Suture mechanical behavior is impacted by morphologic factors (interdigitation and connectivity), which may be optimized for regional loading within the CFS. © 2013 Elsevier Ltd. All rights reserved.
Bio-inspired ``jigsaw''-like interlocking sutures: Modeling, optimization, 3D printing and testing
NASA Astrophysics Data System (ADS)
Malik, I. A.; Mirkhalaf, M.; Barthelat, F.
2017-05-01
Structural biological materials such as bone, teeth or mollusk shells draw their remarkable performance from a sophisticated interplay of architectures and weak interfaces. Pushed to the extreme, this concept leads to sutured materials, which contain thin lines with complex geometries. Sutured materials are prominent in nature, and have recently served as bioinspiration for toughened ceramics and glasses. Sutures can generate large deformations, toughness and damping in otherwise all brittle systems and materials. In this study we examine the design and optimization of sutures with a jigsaw puzzle-like geometry, focusing on the non-linear traction behavior generated by the frictional pullout of the jigsaw tabs. We present analytical models which accurately predict the entire pullout response. Pullout strength and energy absorption increase with higher interlocking angles and for higher coefficients of friction, but the associated high stresses in the solid may fracture the tabs. Systematic optimization reveals a counter-intuitive result: the best pullout performance is achieved with interfaces with low coefficient of friction and high interlocking angle. We finally use 3D printing and mechanical testing to verify the accuracy of the models and of the optimization. The models and guidelines we present here can be extended to other types of geometries and sutured materials subjected to other loading/boundary conditions. The nonlinear responses of sutures are particularly attractive to augment the properties and functionalities of inherently brittle materials such as ceramics and glasses.
Suture cost savings in the OR.
Walsh, Susanna S
2012-05-01
Materials management personnel at a health care facility in Baltimore, Maryland, were stocking too much suture. They stocked suture requested by surgeons or recommended by suture company representatives, and, because the facility is a teaching institution, they stocked suture requested by residents. No master suture database was available to determine what was needed and what was not. As a result, some suture was rarely used, which cost the facility money and took up inventory space. In response, I created a list of the existing inventory and coordinated with the specialty surgical service coordinators to determine which suture was typically used and in what quantities. I used this information to create a master list, with the goal of eliminating the purchase of suture that was not on this list. I gave the staff members and surgeons two months to assess the list and determine whether the suggested suture was sufficient for their needs. I then asked the materials management personnel to order and maintain suture stock based on the master list. This process took approximately four months and shows how health care providers can take a high-volume item, such as suture, and create cost-saving processes that will serve surgeons' and patients' needs while reducing costs and streamlining stock. Copyright © 2012 AORN, Inc. Published by Elsevier Inc. All rights reserved.
Sowerby, Leigh J; Wright, Erin D
2013-11-01
Septoplasty requires coaptation of the mucosal flaps at the conclusion of the procedure; classically this is done with nasal packing. Quilting sutures provide a welcome alternative to packing, but can be time-consuming to place. A septal stapler has recently been developed that provides a rapid alternative to quilting sutures but the timesaving has not been quantified. This study was a prospective, randomized trial comparing a septal stapler to quilting suture for coaptation of mucosal flaps in septoplasty. After meeting inclusion criteria, patients underwent septoplasty and inferior turbinoplasty. The total operative time, surgical segment times, including time for closure was recorded. Preoperative and postoperative Nasal Obstruction Symptom Evaluation (NOSE) scores were recorded. A sample size of 16 was determined to detect a difference of 5 minutes in closure time. A total of 16 patients were enrolled in the study. The mean time for closure with septal stapler was 35 ± 22 seconds vs 7 minutes ± 1 minute 10 seconds for suture closure (p < 0.0001). The mean total operative time using the septal stapler was 28 minutes ± 6 minutes whereas 43 minutes ± 13 minutes was required for suture (p = 0.014). No difference in postoperative complications or mucosal healing was seen; preoperative and postoperative improvement in NOSE scores was comparable. Coaptation of the mucosal flaps in septoplasty with a septal stapler affords a timesaving in the operating room with no difference in operative outcome. © 2013 ARS-AAOA, LLC.
Winkens, Thomas; Nietzsche, Sandor; Gottschaldt, Michael; Freesmeyer, Martin
2014-02-01
A 23-year-old man with follicular thyroid carcinoma and cervical lymph node metastases showed a clear I focus on the skull after radioiodine therapy; therefore, an osseous metastasis was suspected. I and MRI fusion suggested the I focus to be adjacent to an epicranial suture from an early childhood trepanation for epidural hematoma. Radio-guided surgery found dark brown material to be the source of the radiation and successfully removed the material. Subsequent electron microscopy revealed a thread within the dark brown material, suggesting suture material as the cause of I accumulation.
Storch, Mark; Scalzo, Howard; Van Lue, Stephen; Jacinto, Gabriel
2002-01-01
The goal of this study was to compare the physical and functional properties of coated polyglactin 910 suture with and without triclosan by human assessment and instrument-based measurements. Surgeons specializing in general, orthopedic, plastic, or gynecologic surgery evaluated the suture materials in an in vivo porcine model with regard to (1) ease of passage through tissue, (2) first-throw knot holding, (3) knot tie-down smoothness, (4) knot security, (5) surgical handling, and (6) overall evaluation. Breaking strength retention was determined at 14, 21, 28, and 35 days post-implantation in rats using a tensile strength measurement device. The absorption rate was determined in rats by histopathology at 7, 28, 56, 63, 70, and 77 days post-implantation. The tactile smoothness and tie-down behavior of both wet and dry sutures were evaluated by product characterization technicians. The scores for surgeons' evaluation of suture material were favorable and similar for both sutures. Surgeons could not reliably make a distinction in handling between the two sutures. Breaking strength retention was the same for both sutures, ranging from 79% on day 14 to 5% on day 35. Both sutures were essentially absorbed at 70 days post-implantation. Product characterization assessment of the two sutures found them to be indistinguishable. The addition of triclosan to coated polyglactin 910 sutures did not affect physical handling properties or performance characteristics based on the testing and evaluations performed.
Robinson, James R; Frank, Evelyn G; Hunter, Alan J; Jermin, Paul J; Gill, Harinderjit S
2018-03-01
A simple suture technique in transosseous meniscal root repair can provide equivalent resistance to cyclic load and is less technically demanding to perform compared with more complex suture configurations, yet maximum yield loads are lower. Various suture materials have been investigated for repair, but it is currently not clear which material is optimal in terms of repair strength. Meniscal root anatomy is also complex; consisting of the ligamentous mid-substance (root ligament), the transition zone between the meniscal body and root ligament; the relationship between suture location and maximum failure load has not been investigated in a simulated surgical repair. (A) Using a knottable, 2-mm-wide, ultra-high-molecular-weight polyethylene (UHMWPE) braided tape for transosseous meniscal root repair with a simple suture technique will give rise to a higher maximum failure load than a repair made using No. 2 UHMWPE standard suture material for simple suture repair. (B) Suture position is an important factor in determining the maximum failure load. Controlled laboratory study. In part A, the posterior root attachment of the medial meniscus was divided in 19 porcine knees. The tibias were potted, and repair of the medial meniscus posterior root was performed. A suture-passing device was used to place 2 simple sutures into the posterior root of the medial meniscus during a repair procedure that closely replicated single-tunnel, transosseous surgical repair commonly used in clinical practice. Ten tibias were randomized to repair with No. 2 suture (Suture group) and 9 tibias to repair with 2-mm-wide knottable braided tape (Tape group). The repair strength was assessed by maximum failure load measured by use of a materials testing machine. Micro-computed tomography (CT) scans were obtained to assess suture positions within the meniscus. The wide range of maximum failure load appeared related to suture position. In part B, 10 additional porcine knees were prepared. Five knees were randomized to the Suture group and 5 to the Tape group. All repairs were standardized for location, and the repair was placed in the body of the meniscus. A custom image registration routine was created to coregister all 29 menisci, which allowed the distribution of maximum failure load versus repair location to be visualized with a heat map. In part A, higher maximum failure load was found for the Tape group (mean, 86.7 N; 95% CI, 63.9-109.6 N) compared with the Suture group (mean, 57.2 N; 95% CI, 30.5-83.9 N). The 3D micro-CT analysis of suture position showed that the mean maximum failure load for repairs placed in the meniscus body (mean, 104 N; 95% CI, 81.2-128.0 N) was higher than for those placed in the root ligament (mean, 35.1 N; 95% CI, 15.7-54.5 N). In part B, the mean maximum failure load was significantly greater for the Tape group, 298.5 N ( P = .016, Mann-Whitney U; 95% CI, 183.9-413.1 N), compared with that for the Suture group, 146.8 N (95% CI, 82.4-211.6 N). Visualization with the heat map revealed that small variations in repair location on the meniscus were associated with large differences in maximum failure load; moving the repair entry point by 3 mm could reduce the failure load by 50%. The use of 2-mm braided tape provided higher maximum failure load than the use of a No. 2 suture. The position of the repair in the meniscus was also a highly significant factor in the properties of the constructs. The results provide insight into material and location for optimal repair strength.
Bacterial biofilms on implanted suture material are a cause of surgical site infection.
Kathju, Sandeep; Nistico, Laura; Tower, Irene; Lasko, Leslie-Ann; Stoodley, Paul
2014-10-01
Surgical site infection (SSI) has been estimated to occur in up to 5% of all procedures, accounting for up to 0.5% of all hospital costs. Bacterial biofilms residing on implanted foreign bodies have been implicated as contributing or causative factors in a wide variety of infectious scenarios, but little consideration has been given to the potential for implanted, submerged suture material to act as a host for biofilm and thus serve as a nidus of infection. We report a series of 15 patients who underwent open Roux-en-Y gastric bypass (with musculofascial closure with permanent, multifilament sutures) who developed longstanding and refractory SSIs in the abdominal wall. Explanted suture material at subsequent exploration was examined for biofilm with confocal laser-scanning microscopy (CLSM) and fluorescence in situ hybridization (FISH). All 15 patients at re-exploration were found to have gross evidence of a "slimy" matrix or dense reactive granulation tissue localized to the implanted sutures. Confocal laser-scanning microscopy revealed abundant biofilm present on all sutures examined; FISH was able to identify the presence of specific pathogens in the biofilm. Complete removal of the foreign bodies (and attendant biofilms) resulted in all cases in cure of the SSI. Bacterial biofilms on implanted suture material can manifest as persistent surgical site infections that require complete removal of the underlying foreign body substrata for resolution.
Baums, M H; Buchhorn, G H; Spahn, G; Poppendieck, B; Schultz, W; Klinger, H-M
2008-11-01
The aim of the study was to evaluate the time zero mechanical properties of single- versus double-row configuration for rotator cuff repair in an animal model with consideration of the stitch technique and suture material. Thirty-two fresh-frozen sheep shoulders were randomly assigned to four repair groups: suture anchor single-row repair coupled with (1) braided, nonabsorbable polyester suture sized USP No. 2 (SRAE) or (2) braided polyblend polyethylene suture sized No. 2 (SRAH). The double-row repair was coupled with (3) USP No. 2 (DRAE) or (4) braided polyblend polyethylene suture No. 2 (DRAH). Arthroscopic Mason-Allen stitches were used (single-row) and combined with medial horizontal mattress stitches (double-row). Shoulders were cyclically loaded from 10 to 180 N. Displacement to gap formation of 5- and 10-mm at the repair site, cycles to failure, and the mode of failure were determined. The ultimate tensile strength was verified in specimens that resisted to 3,000 cycles. DRAE and DRAH had a lower frequency of 5- (P = 0.135) and 10-mm gap formation (P = 0.135). All DRAE and DRAH resisted 3,000 cycles while only three SRAE and one SRAH resisted 3,000 cycles (P < 0.001). The ultimate tensile strength in double-row specimens was significantly higher than in others (P < 0.001). There was no significant variation in using different suture material (P > 0.05). Double-row suture anchor repair with arthroscopic Mason-Allen/medial mattress stitches provides initial strength superior to single-row repair with arthroscopic Mason-Allen stitches under isometric cyclic loading as well as under ultimate loading conditions. Our results support the concept of double-row fixation with arthroscopic Mason-Allen/medial mattress stitches in rotator cuff tears with improvement of initial fixation strength and ultimate tensile load. Use of new polyblend polyethylene suture material seems not to increase the initial biomechanical aspects of the repair construct.
Shao, Pengfei; Li, Pu; Ju, Xiaobing; Qin, Chao; Li, Jie; Lv, Qiang; Meng, Xiaoxin; Yin, Changjun
2015-02-01
To study the feasibility and safety of laparoscopic radical cystectomy with intracorporeal orthotopic ileal neobladder and to evaluate the role of endoscopic stapling in neobladder construction. Fifty-five patients with bladder cancer who underwent laparoscopic radical cystectomy were retrospectively examined. Extended pelvic lymph node dissection was performed before cystectomy. An ileal segment of 50 cm was harvested to construct a U-shaped reservoir. The bottom of the reservoir was anastomosed with the posterior urethra. Twenty-five patients underwent neobladder construction by manual suturing and 30 patients by endoscopic stapler suturing. The mean operative time was 346 minutes, and mean neobladder construction time was 230 minutes. The median estimated blood loss was 500 mL, and 17 patients received intraoperative transfusion. Postoperative complications included 2 cases of urine leakage, 7 cases of pyelonephritis, 4 cases of incomplete bowel obstruction, 1 case of anastomotic stricture, and 1 case of death. Endoscopic stapler suturing for neobladder construction took significantly less time than manual suturing. However, neobladder stones were found in 2 patients who underwent operation using endoscopic suturing, and the stones were removed cystoscopically. The functional outcomes of the 2 constructive methods were comparable. Laparoscopic radical cystectomy with intracorporeal orthotopic neobladder is safe and feasible for experienced laparoscopic surgeons. Application of endoscopic stapler simplifies the surgical procedure while increasing the risk of neobladder stone formation. Copyright © 2015 Elsevier Inc. All rights reserved.
Pyeloplasty techniques using minimally invasive surgery (MIS) in pediatric patients.
Turrà, Francesco; Escolino, Maria; Farina, Alessandra; Settimi, Alessandro; Esposito, Ciro; Varlet, François
2016-10-01
Hydronephrosis is the most common presentation of ureteropelvic junction (UPJ) obstruction. We reviewed literature, collecting data from Medline, to evaluate the current status of minimally invasive surgery (MIS) approach to pyeloplasty. Since the first pyeloplasty was described in 1939, several techniques has been applied to correct UPJ obstruction, but Anderson-Hynes dismembered pyeloplasty is established as the gold standard, to date also in MIS technique. According to literature several studies underline the safety and effectiveness of this approach for both trans- and retro-peritoneal routes, with a success rate between 81-100% and an operative time between 90-228 min. These studies have demonstrated the safety and efficacy of this procedure in the management of UPJ obstruction in children. Whether better the transperitoneal, than the retroperitoneal approach is still debated. A long learning curve is needed especially in suturing and knotting.
Tensile strength and failure load of sutures for robotic surgery.
Abiri, Ahmad; Paydar, Omeed; Tao, Anna; LaRocca, Megan; Liu, Kang; Genovese, Bradley; Candler, Robert; Grundfest, Warren S; Dutson, Erik P
2017-08-01
Robotic surgical platforms have seen increased use among minimally invasive gastrointestinal surgeons (von Fraunhofer et al. in J Biomed Mater Res 19(5):595-600, 1985. doi: 10.1002/jbm.820190511 ). However, these systems still suffer from lack of haptic feedback, which results in exertion of excessive force, often leading to suture failures (Barbash et al. in Ann Surg 259(1):1-6, 2014. doi: 10.1097/SLA.0b013e3182a5c8b8 ). This work catalogs tensile strength and failure load among commonly used sutures in an effort to prevent robotic surgical consoles from exceeding identified thresholds. Trials were thus conducted on common sutures varying in material type, gauge size, rate of pulling force, and method of applied force. Polydioxanone, Silk, Vicryl, and Prolene, gauges 5-0 to 1-0, were pulled till failure using a commercial mechanical testing system. 2-0 and 3-0 sutures were further tested for the effect of pull rate on failure load at rates of 50, 200, and 400 mm/min. 3-0 sutures were also pulled till failure using a da Vinci robotic surgical system in unlooped, looped, and at the needle body arrangements. Generally, Vicryl and PDS sutures had the highest mechanical strength (47-179 kN/cm 2 ), while Silk had the lowest (40-106 kN/cm 2 ). Larger diameter sutures withstand higher total force, but finer gauges consistently show higher force per unit area. The difference between material types becomes increasingly significant as the diameters decrease. Comparisons of identical suture materials and gauges show 27-50% improvement in the tensile strength over data obtained in 1985 (Ballantyne in Surg Endosc Other Interv Tech 16(10):1389-1402, 2002. doi: 10.1007/s00464-001-8283-7 ). No significant differences were observed when sutures were pulled at different rates. Reduction in suture strength appeared to be strongly affected by the technique used to manipulate the suture. Availability of suture tensile strength and failure load data will help define software safety protocols for alerting a surgeon prior to suture failure during robotic surgery. Awareness of suture strength weakening with direct instrument manipulation may lead to the development of better techniques to further reduce intraoperative suture breakage.
21 CFR 74.3106 - D&C Blue No. 6.
Code of Federal Regulations, 2010 CFR
2010-04-01
... material for coloring plain or chromic collagen absorbable sutures for general surgical use; (iii) Not to exceed 0.5 percent by weight of the suture material for coloring plain or chromic collagen absorbable...
21 CFR 74.3106 - D&C Blue No. 6.
Code of Federal Regulations, 2014 CFR
2014-04-01
... material for coloring plain or chromic collagen absorbable sutures for general surgical use; (iii) Not to exceed 0.5 percent by weight of the suture material for coloring plain or chromic collagen absorbable...
21 CFR 74.3106 - D&C Blue No. 6.
Code of Federal Regulations, 2012 CFR
2012-04-01
... material for coloring plain or chromic collagen absorbable sutures for general surgical use; (iii) Not to exceed 0.5 percent by weight of the suture material for coloring plain or chromic collagen absorbable...
21 CFR 74.3106 - D&C Blue No. 6.
Code of Federal Regulations, 2011 CFR
2011-04-01
... material for coloring plain or chromic collagen absorbable sutures for general surgical use; (iii) Not to exceed 0.5 percent by weight of the suture material for coloring plain or chromic collagen absorbable...
21 CFR 74.3106 - D&C Blue No. 6.
Code of Federal Regulations, 2013 CFR
2013-04-01
... material for coloring plain or chromic collagen absorbable sutures for general surgical use; (iii) Not to exceed 0.5 percent by weight of the suture material for coloring plain or chromic collagen absorbable...
Giusto, Gessica; Tramuta, Clara; Caramello, Vittorio; Comino, Francesco; Nebbia, Patrizia; Robino, Patrizia; Singer, Ellen; Grego, Elena; Gandini, Marco
2017-01-01
The objective of this study was to investigate whether cleaning surgical materials used to close pelvic flexure enterotomies with a wet sterile gauze will reduce contamination and whether the use of a full thickness appositional suture pattern (F) or a partial thickness inverting (or Cushing) suture pattern (C) would make a difference in the level of contamination. Large colon specimens were assigned to group F or C and divided into subgroups N and G. In group G, a wet sterile gauze was passed over the suture material, another over the instruments, and another over the gloves. In group N, no treatment was applied. The bacterial concentration was measured by optical density (OD) at 24 h. The OD of subgroup CG was lower than that of subgroup CN ( P = 0.019). The OD of subgroup FG was lower than that of subgroup FN ( P = 0.02). The OD of subgroups CG, CN, FG, and FN was lower than that of the negative control ( P < 0.003, P < 0.001, P < 0.001, and P < 0.00). The use of a sterile wet gauze significantly reduced contamination of suture materials. A partial thickness inverting suture pattern did not produce less contamination than a full thickness appositional suture pattern.
Farrah, S R; Erdos, G W
1991-06-01
Two procedures were used to modify gauze bandages, polyester sutures, silicone tubing, and polyvinyl chloride tubing. In one procedure, the materials were first modified by in situ precipitation of metallic hydroxides and then used to adsorb silver ions. In the second procedure, the materials were soaked in sodium pyrophosphate or sodium chloride, dried, and then soaked in silver nitrate. These procedures produced materials with silver deposited on the surface of the tubing and sutures and both on the surface and within the gauze fibers. The modified materials inhibited the growth of Pseudomonas aeruginosa. Escherichia coli, and Staphylococcus aureus in vitro.
Ivasauskas, Tomas J.; Bettoli, P.W.; Holt, T.
2012-01-01
We examined the effects of suture material (braided silk versus Monocryl) and relative ultrasonic transmitter size on healing, growth, mortality, and tag retention in rainbow trout Oncorhynchus mykiss. In experiment 1, 40 fish (205-281mmtotal length [TL], 106-264 g) were implanted with Sonotronics IBT-96-2 (23??7 mm; weight in air, 4.4 g; weight in water, 2.4 g) or IBT 96-2E (30 ?? 7 mm; weight in air, 4.9 g; weight in water, 2.4 g) ultrasonic telemetry tags. In experiment 2, 20 larger fish (342-405 mm TL; 520-844 g) were implanted with Sonotronics IBT-96-5 ultrasonic tags (36 ?? 11 mm; weight in air, 9.1 g; weight in water, 4.1 g). The tag burdens for all implanted fish ranged from 1.1% to 3.4%, and fish in both studies were held at 10-15??C. At the conclusion of both experiments (65 d after surgery), no mortalities were observed in any of the 60 tagged fish, most incisions were completely healed, and all fish in both experiments grew in length, although tagged fish grew more slowly than control fish in experiment 1. In both experiments, fish sutured with silk expelled tags more frequently than those sutured with Monocryl. Expulsion was observed in 45-50% of the fish sutured with silk and 0-25% of the fish sutured withMonocryl. Tag expulsion was not observed until 25-35 d after surgery. Fish sutured with silk exhibited a more severe inflammatory response 3 weeks after surgery than those sutured with Monocryl. In experiment 1, the rate of expulsion was linked to the severity of inflammation. Although braided silk sutures were applied faster than Moncryl sutures in both experiments, knots tied with either material were equally reliable and fish sutured with Monocryl experienced less inflammation and lower rates of tag expulsion. American Fisheries Society 2012.
Chanda, Arnab; Unnikrishnan, Vinu; Flynn, Zachary; Lackey, Kim
2017-01-01
Skin injuries are the most common type of injuries occurring in day-to-day life. A skin injury usually manifests itself in the form of a wound or a cut. While a shallow wound may heal by itself within a short time, deep wounds require surgical interventions such as suturing for timely healing. To date, suturing practices are based on a surgeon's experience and may vary widely from one situation to another. Understanding the mechanics of wound closure and suturing of the skin is crucial to improve clinical suturing practices and also to plan automated robotic surgeries. In the literature, phenomenological two-dimensional computational skin models have been developed to study the mechanics of wound closure. Additionally, the effect of skin pre-stress (due to the natural tension of the skin) on wound closure mechanics has been studied. However, in most of these analyses, idealistic two-dimensional skin geometries, materials and loads have been assumed, which are far from reality, and would clearly generate inaccurate quantitative results. In this work, for the first time, a biofidelic human skin tissue phantom was developed using a two-part silicone material. A wound was created on the phantom material and sutures were placed to close the wound. Uniaxial mechanical tests were carried out on the phantom specimens to study the effect of varying wound size, quantity, suture and pre-stress on the mechanical behavior of human skin. Also, the average mechanical behavior of the human skin surrogate was characterized using hyperelastic material models, in the presence of a wound and sutures. To date, such a robust experimental study on the effect of injury and sutures on human skin mechanics has not been attempted. The results of this novel investigation will provide important guidelines for surgical planning and validation of results from computational models in the future.
Laparoscopic laser soldering for repair of ureteropelvic junction obstruction in the porcine model.
Shumalinsky, Dmitry; Lobik, Leonid; Cytron, Shmuel; Halpern, Marisa; Vasilyev, Tamar; Ravid, Avi; Katzir, Abraham
2004-03-01
Laparoscopic pyeloplasty is used for the repair of ureteropelvic junction (UPJ) obstruction. Our objective was to introduce laser soldering to this procedure. We developed a system based on a CO2 laser, an infrared detector, and two infrared transmitting optical fibers to obtain temperature-controlled laser soldering of cuts in tissues. The system was used for laparoscopic soldering of incisions in the kidneys of pigs. We carried out laparoscopic pyeloplasty successfully in a porcine model using fiberoptic laser soldering. Laparoscopic laser soldering was found to be faster than suturing. It was easier to use and provided watertight bonding. This technique will be useful in pyeloplasty as well as other laparoscopic surgical procedures.
Dietz, U A; Araújo, A C F; Czeczko, N G; Lemos, R; Araújo, U; Inácio, C M; Salles, G; Corrêa Neto, M; Repka, J C D; Zanellato, C M F; Malafaia, O; Debus, E S; Thiede, A
2005-06-01
Esophagojejunostomy after total gastrectomy still remains a high risk anastomosis with a considerable morbidity and mortality. The majority of these anastomoses are performed by the intraluminal stapler technique, yet stenoses are a known late complication even after an uneventful postoperative course. In the present study, the osophagojejunostomy with the biofragmentable anastomosis ring (BAR) was examined in dogs. 28 dogs were randomized into a group of manual suture (n = 14) and a BAR-group (n = 14). After gastrectomy, the esophagojejunostomy was performed by hand-suture with polypropylene 4-0 in the manual suture group, and with the 25/1.5 mm BAR in the BAR-group. In both groups the Roux-en-Y jejunojejunostomy was performed by hand-suture. The dogs were evaluated on postoperative days 4, 7 and 14 with regard to macroscopy, bursting strength, tissue hydroxyproline and histology. There was one leakage without clinical effect in the hand-sewn group on postoperative day 4; there was no leak in the BAR-group. In observing fibre-free enteral feeding, neither functional disorders nor obstruction of the BAR were observed. The general anastomosis parameters were matchable between the groups. The infracarinal BAR-esophagojejunostomy is comparable to the hand-sewn anastomosis in the dog-model.
Giusto, Gessica; Tramuta, Clara; Caramello, Vittorio; Comino, Francesco; Nebbia, Patrizia; Robino, Patrizia; Singer, Ellen; Grego, Elena; Gandini, Marco
2017-01-01
The objective of this study was to investigate whether cleaning surgical materials used to close pelvic flexure enterotomies with a wet sterile gauze will reduce contamination and whether the use of a full thickness appositional suture pattern (F) or a partial thickness inverting (or Cushing) suture pattern (C) would make a difference in the level of contamination. Large colon specimens were assigned to group F or C and divided into subgroups N and G. In group G, a wet sterile gauze was passed over the suture material, another over the instruments, and another over the gloves. In group N, no treatment was applied. The bacterial concentration was measured by optical density (OD) at 24 h. The OD of subgroup CG was lower than that of subgroup CN (P = 0.019). The OD of subgroup FG was lower than that of subgroup FN (P = 0.02). The OD of subgroups CG, CN, FG, and FN was lower than that of the negative control (P < 0.003, P < 0.001, P < 0.001, and P < 0.00). The use of a sterile wet gauze significantly reduced contamination of suture materials. A partial thickness inverting suture pattern did not produce less contamination than a full thickness appositional suture pattern. PMID:28154467
Evaluation of four suture materials for surgical incision closure in Siberian sturgeon
Boone, S. Shaun; Hernandez, Sonia M.; Camus, Alvin C.; Peterson, Douglas C.; Jennings, Cecil A.; Shelton, James L.; Divers, Stephen J.
2015-01-01
The visual and microscopic tissue reactions to the absorbable monofilament Monocryl, absorbable monofilament triclosan-coated Monocryl-Plus, absorbable multifilament Vicryl, and nonabsorbable monofilament Prolene were evaluated for their use of surgical closure in Siberian Sturgeon Acipenser baerii. Postoperative assessments were conducted at 1, 2, 8, 12, and 26 and 55 weeks to visually evaluate the surgical incision for suture retention, incision healing, erythema, and swelling. Incisions were also assessed microscopically at 1, 2, and 8 weeks for necrosis, inflammation, hemorrhage, and fibroplasia. The results indicated that incisions closed with either Vicryl or Prolene suture materials were more likely to exhibit more erythema or incomplete healing compared with those closed with Monocryl or Monocryl-Plus. The surgical implantation of a transmitter in the coelomic cavity did not significantly affect the response variables among the four suture materials. Monocryl or Monocryl-Plus were equally effective and superior to other suture materials used for closing surgical incisions in Siberian Sturgeon or closely related species of sturgeon. Furthermore, Monocryl or Monocryl-Plus may decrease the risk of transmitter expulsion through the incision, as surgical wounds appear to heal faster and exhibit less erythema compared with those closed with Vicryl.
Walsh, M.G.; Bjorgo, K.A.; Isely, J.J.
2000-01-01
To determine the effects of surgical implantation method and temperature on mortality and transmitter loss, we compared two antenna placements (trailing antenna versus shielded needle) and two suture materials (absorbable versus nonabsorbable) in hybrid striped bass Morone saxitilis x Morone chrysops (227-410 mm total length) that had been surgically implanted with simulated transmitters and held at high (22-29??C) and low (12-18??C) temperatures for 120 d. Fish were individually examined after 7, 30, 60. 90. and 120 d to evaluate suture and wound condition as well as transmitter loss. Neither suture material nor antenna placement affected transmitter loss, mortality, or growth at either high or low temperatures. Absorbable sutures were lost more quickly than were nonabsorbable sutures, but they persisted beyond incision closure at both high and low temperatures. At high temperatures, 50% suture loss occurred by 30 d for absorbable sutures and by 60 d for nonabsorbable sutures. Mortality occurred only at high temperatures but was delayed and was likely caused by peritoneal infection. Transmitter loss was not significant; it occurred only in the low-temperature trial and was caused by pressure necrosis at the incision rather than by suture failure. Temperature significantly affected all responses examined in this study. Significant irritation, infection, and mortality occurred in all treatment groups at high temperatures.
Hong, Bujung; Winkel, Andreas; Ertl, Philipp; Stumpp, Sascha Nico; Schwabe, Kerstin; Stiesch, Meike; Krauss, Joachim K
2018-03-01
Wound healing impairment is a serious problem in surgical disciplines which may be associated with chronic morbidity, increased cost and patient discomfort. Here we aimed to investigate the relevance of bacterial colonisation on suture material using polymerase chain reaction (PCR) to detect and taxonomically classify bacterial DNA in patients with and without wound healing problems after routine neurosurgical procedures. Repeat surgery was performed in 25 patients with wound healing impairment and in 38 patients with well-healed wounds. To determine the presence of bacteria, a 16S rDNA-based PCR detection method was applied. Fragments of 500 bp were amplified using universal primers which target hypervariable regions within the bacterial 16S rRNA gene. Amplicons were separated from each other by single-strand conformation polymorphism (SSCP) analysis, and finally classified using Sanger sequencing. PCR/SSCP detected DNA of various bacteria species on suture material in 10/38 patients with well-healed wounds and in 12/25 patients with wound healing impairment including Staphylococcus aureus, Staphylococcus epidermidis, Propionibacterium acnes and Escherichia coli. Microbiological cultures showed bacterial growth in almost all patients with wound healing impairment and positive results in PCR/SSCP (10/12), while this was the case in only one patient with a well-healed wound (1/10). Colonisation of suture material with bacteria occurs in a relevant portion of patients with and without wound healing impairment after routine neurosurgical procedures. Suture material may provide a nidus for bacteria and subsequent biofilm formation. Most likely, however, such colonisation of sutures is not a general primer for subsequent wound infection.
Tissue reactions to modern suturing material in colorectal surgery.
Molokova, O A; Kecherukov, A I; Aliev, F Sh; Chernov, I A; Bychkov, V G; Kononov, V P
2007-06-01
Morphological changes in the wall of the large intestine were studied after its manual suturing by a double-row interrupted suture with modern suture threads. Light and scanning electron microscopy showed "fuse properties" and "sawing effect" of polyfilament twisted threads (e.g. vicryl). Monofilament threads were free from these drawbacks and therefore were preferable. Metal elastic threads on the basis of titanium-nickelide alloys caused no inflammatory changes in tissues.
Selective laser vaporization of polypropylene sutures and mesh
NASA Astrophysics Data System (ADS)
Burks, David; Rosenbury, Sarah B.; Kennelly, Michael J.; Fried, Nathaniel M.
2012-02-01
Complications from polypropylene mesh after surgery for female stress urinary incontinence (SUI) may require tedious surgical revision and removal of mesh materials with risk of damage to healthy adjacent tissue. This study explores selective laser vaporization of polypropylene suture/mesh materials commonly used in SUI. A compact, 7 Watt, 647-nm, red diode laser was operated with a radiant exposure of 81 J/cm2, pulse duration of 100 ms, and 1.0-mm-diameter laser spot. The 647-nm wavelength was selected because its absorption by water, hemoglobin, and other major tissue chromophores is low, while polypropylene absorption is high. Laser vaporization of ~200-μm-diameter polypropylene suture/mesh strands, in contact with fresh urinary tissue samples, ex vivo, was performed. Non-contact temperature mapping of the suture/mesh samples with a thermal camera was also conducted. Photoselective vaporization of polypropylene suture and mesh using a single laser pulse was achieved with peak temperatures of 180 and 232 °C, respectively. In control (safety) studies, direct laser irradiation of tissue alone resulted in only a 1 °C temperature increase. Selective laser vaporization of polypropylene suture/mesh materials is feasible without significant thermal damage to tissue. This technique may be useful for SUI procedures requiring surgical revision.
Laparoscopic jejunostomy for obstructing upper gastrointestinal malignancies
TSUJIMOTO, HIRONORI; HIRAKI, SHUICHI; TAKAHATA, RISA; NOMURA, SHINSUKE; ITO, NOZOMI; KANEMATSU, KYOHEI; HORIGUCHI, HIROYUKI; AOSASA, SUEFUMI; YAMAMOTO, JUNJI; HASE, KAZUO
2015-01-01
The aim of this study was to describe a minimally invasive laparoscopic jejunostomy (Lap-J) technique for obstruction due to upper gastrointestinal malignancies and evaluate the nutritional benefit of Lap-J during neoadjuvant chemotherapy (NAC) in cases with obstructing esophageal cancer. Under general anesthesia, the jejunum 20–30 cm distant from the Treitz ligament was pulled out through an extended umbilical laparoscopic incision and a jejunal tube was inserted to 30 cm. The loop of bowel was gently returned to the abdomen and the feeding tube was drawn through the abdominal wall via the left lower incision. The jejunum was then laparoscopically sutured to the anterior abdominal wall. Lap-J was performed in 26 cases. The median operative time was 82 min. The postoperative course was uneventful. Lap-J prior to NAC was not associated with a decrease in body weight or serum total protein during NAC, compared with patients who received NAC without Lap-J. This minimally invasive jejunostomy technique may be particularly useful in patients in whom endoscopic therapy is not feasible due to obstruction from upper gastrointestinal malignancies. PMID:26807238
Stable fixation with absorbable sutures in craniofacial surgery.
Linz, C; Kunz, F; Krauß, J; Böhm, H; Wirth, C; Hartmann, S; Wirbelauer, J; Schweitzer, T
2016-05-01
The present study analyses the exclusive use of absorbable suture material (Vicryl(®), Ethicon, Germany) in the fixation of transposed bone segments in craniofacial surgery without modification of the osteotomy design. Among 129 children up to 24 months of age, osteosynthesis was conducted exclusively with Vicryl(®) sutures. The stability of postoperative results was evaluated and possible foreign body reactions were examined within the framework of clinical and radiological routine checks. All examined children exhibited stable postoperative conditions while the length of hospital stay was not affected. X-ray examinations of the skull in two planes demonstrated good bony union in all cases. Relevant foreign body reactions were not observed. The exclusive application of absorbable suture material enables stable and cost effective osteosynthesis. Significant foreign body reactions were not observed. The exclusive use of absorbable sutures did not alter the osteotomy design. Copyright © 2016 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Li, Yaning; Song, Juha; Ortiz, Christine; Boyce, Mary; Ortiz Group/DMSE/MIT Team; Boyce Group/ME/MIT Team
2011-03-01
Biological sutures are joints which connect two stiff skeletal or skeletal-like components. These joints possess a wavy geometry with a thin organic layer providing adhesion. Examples of biological sutures include mammalian skulls, the pelvic assembly of the armored fish Gasterosteus aculeatus (the three-spined stickleback), and the suture joints in the shell of the red-eared slider turtle. Biological sutures allow for movement and compliance, control stress concentrations, transmit loads, reduce fatigue stress and absorb energy. In this investigation, the mechanics of the role of suture geometry in providing a naturally optimized joint is explored. In particular, analytical and numerical micromechanical models of the suture joint are constructed. The anisotropic mechanical stiffness and strength are studied as a function of suture wavelength, amplitude and the material properties of the skeletal and organic components, revealing key insights into the optimized nature of these ubiquitous natural joints.
Absorbable synthetic versus catgut suture material for perineal repair
Kettle, Christine
2014-01-01
Background Approximately 70% of women will experience some degree of perineal trauma following vaginal delivery and will require stitches. This may result in perineal pain and superficial dyspareunia. Objectives The objective of this review was to assess the effects of absorbable synthetic suture material as compared with catgut on the amount of short and long term pain experienced by mothers following perineal repair. Search strategy We searched the Cochrane Pregnancy and Childbirth Group’s Trials Register. Selection criteria Randomised trials comparing absorbable synthetic (polyglycolic acid and polyglactin) with plain or chromic catgut suture for perineal repair in mothers after vaginal delivery. Data collection and analysis Trial quality was assessed independently by two reviewers. Data were extracted by one reviewer and checked by the second reviewer. Main results Eight trials were included. Compared with catgut, the polyglycolic acid and polyglactin groups were associated with less pain in first three days (odds ratio 0.62, 95% confidence interval 0.54 to 0.71). There was also less need for analgesia (odds ratio 0.63, 95% confidence interval 0.52 to 0.77) and less suture dehiscence (odds ratio 0.45, 95% confidence interval 0.29 to 0.70). There was no significant difference in long term pain (odds ratio 0.81, 95% confidence interval 0.61 to 1.08). Removal of suture material was significantly more common in the polyglycolic acid and polyglactin groups (odds ratio 2.01, 95% confidence interval 1.56 to 2.58). There was no difference in the amount of dyspareunia experienced by women. Authors’ conclusions Absorbable synthetic suture material (in the form of polyglycolic acid and polyglactin sutures) for perineal repair following childbirth appears to decrease women’s experience of short-term pain. The length of time taken for the synthetic material to be absorbed is of concern. A trial addressing the use of polyglactin has recently been completed and this has been included in this updated review. PMID:10796081
Poppas, D P; Klioze, S D; Uzzo, R G; Schlossberg, S M
1995-02-01
Laser tissue welding in genitourinary reconstructive surgery has been shown in animal models to decrease operative time, improve healing, and decrease postoperative fistula formation when compared with conventional suture controls. Although the absence of suture material is the ultimate goal, this has not been shown to be practical with current technology for larger repairs. Therefore, suture-assisted laser tissue welding will likely be performed. This study sought to determine the optimal suture to be used during laser welding. The integrity of various organic and synthetic sutures exposed to laser irradiation were analyzed. Sutures studied included gut, clear Vicryl, clear polydioxanone suture (PDS), and violet PDS. Sutures were irradiated with a potassium titanyl phosphate (KTP)-532 laser or an 808-nm diode laser with and without the addition of a light-absorbing chromophore (fluorescein or indocyanine green, respectively). A remote temperature-sensing device obtained real-time surface temperatures during lasing. The average temperature, time, and total energy at break point were recorded. Overall, gut suture achieved significantly higher temperatures and withstood higher average energy delivery at break point with both the KTP-532 and the 808-nm diode lasers compared with all other groups (P < 0.05). Both chromophore-treated groups had higher average temperatures at break point combined with lower average energy. The break-point temperature for all groups other than gut occurred at 91 degrees C or less. The optimal temperature range for tissue welding appears to be between 60 degrees and 80 degrees C. Gut suture offers the greatest margin of error for KTP and 808-nm diode laser welding with or without the use of a chromophore.
Swearingen, Matthew C; DiBartola, Alex C; Dusane, Devendra; Granger, Jeffrey; Stoodley, Paul
2016-10-01
Bacterial biofilms are the main etiological agent of periprosthetic joint infections (PJI); however, it is unclear if biofilms colonize one or multiple components. Because biofilms can colonize a variety of surfaces, we hypothesized that biofilms would be present on all components. 16S ribosomal RNA (rRNA) gene sequencing analysis was used to identify bacteria recovered from individual components and non-absorbable suture material recovered from three PJI total knee revision cases. Bray-Curtis non-metric multidimensional scaling analysis revealed no significant differences in similarity when factoring component, material type, or suture versus non-suture material, but did reveal significant differences in organism profile between patients (P < 0.001) and negative controls (P < 0.001). Confocal microscopy and a novel agar encasement culturing method also confirmed biofilm growth on a subset of components. While 16S sequencing suggested that the microbiology was more complex than revealed by culture contaminating, bacterial DNA generates a risk of false positives. This report highlights that biofilm bacteria may colonize all infected prosthetic components including braided suture material, and provides further evidence that clinical culture can fail to sufficiently identify the full pathogen profile in PJI cases. © FEMS 2016. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Sanders, Ruth E; Kearney, Clodagh M; Buckley, Conor T; Jenner, Florien; Brama, Pieter A
2015-08-01
To evaluate knot security for 3 knot types created in 3 commonly used 5 metric suture materials incubated in physiological and pathological fluids. In vitro mechanical study. Knotted suture loops (n = 5/group). Loops of 3 different suture materials (glycolide/lactide copolymer; polyglactin 910; polydioxanone) were created around a 20 mm rod using 3 knot types (square [SQ], surgeon's [SK], and triple knot [TK]) and were tested to failure in distraction (6 mm/min) after tying (day 0) and after being incubated for 14 and 28 days in phosphate buffered saline (PBS) or inflamed peritoneal fluid. Failure load (N) and mode were recorded and compared. For polydioxanone, significant differences in force to knot failure were found between SQ and SK/TK but not between SK and TK. The force required to break all constructs increased after incubation in phosphate buffered saline (PBS). With glycolide/lactide copolymer no differences in force to knot failure were observed. With polyglactin 910, a significant difference between SQ and TK was observed, which was not seen between the other knot types. Incubation in inflamed peritoneal fluid caused a larger and more rapid decrease in force required to cause knot failure than incubation in PBS. Mechanical properties of suture materials have significant effects on knot security. For polydioxanone, SQ is insufficient to create a secure knot. Additional wraps above a SK confer extra stability in some materials, but this increase may not be clinically relevant or justifiable. Glycolide/lactide copolymer had excellent knot security. © Copyright 2015 by The American College of Veterinary Surgeons.
Maksoud, Mohamed; Koo, Samuel; Barouch, Kasumi; Karimbux, Nadeem
2014-02-01
The aim of the present study was to determine the favoritism of suture materials among a group of clinicians at a teaching institution. The surveys included 11 absorbable and nine non-absorbable sutures. The surveyor was asked to select his or her suture preferences when it comes to using it in 13 different, commonly-performed surgical procedures. The surveys showed overall preferences for non-absorbable versus absorbable sutures. Chromic Gut with a 4-0 diameter thread reverse cutting FS2 needle was the most favored suture. For periodontal bone grafts and hard tissue ridge augmentation, polytetrafluoroethylene with a 4-0 thread and FS2 needle was preferred. For autogenous gingival grafts, gingival allografts, connective tissue grafts, frenectomy and frenoplasty, Chromic Gut with 5-0 diameter thread reverse cutting P3 needle was favored. For extraction socket preservation, soft tissue canine exposure, ridge augmentation, and dental implants, Chromic Gut with 4-0 diameter thread reverse cutting FS2 needle was preferred, and for sinus augmentation, Vicryl with a 4-0 diameter thread reverse cutting FS2 needle was favored. Absorbable sutures were preferred in the majority of periodontal procedures; however, non-absorbable sutures were favored in procedures that required longer healing or better stability of the flap edges in cases of periodontal and ridge augmentation. © 2013 Wiley Publishing Asia Pty Ltd.
Robot-assisted bronchoplasty using continuous barbed sutures.
Sarsam, Omar Matthieu; Dunning, Joel; Pochulu, Bruno; Baste, Jean-Marc
2018-01-01
We describe in this article our bronchoplastic robot-assisted techniques. This consists of using continuous barbed sutures. Our aim is to show the feasibility and the interest of using robotics and this kind of suture material for complex bronchial procedures. We report four cases in France and the UK, two wedge bronchoplasties and two sleeve bronchoplasties for central pulmonary tumors.
Ferrone, Roberto; Scarone, Pier Carlo; Natalini, Gianni
2003-09-01
We describe a case of small bowel obstruction due to prosthetic mesh migration. A 67-year-old male, who had undergone prosthetic repair of inguinal hernia 3 years before, was admitted for a mechanical small bowel obstruction. Laparotomy revealed the penultimate ileal loop choked by an adhesion drawing it towards a polypropylene mesh, firmly attached to the parietal peritoneum of the inguinal region. The intestinal loop was released; the mesh was embedded deep with continuous whip suture after folding the parietal peritoneum. The patient was dismissed on the 11th postoperative day surgically healed. The "tension-free" technique is undoubtedly the gold standard for hernia repair. However, it is not free of complications, mostly due to technical errors, of which the surgeon must be aware, both when he is responsible for correcting defects in the wall, as well as when he has to face an occlusion in a patient who has undergone plastic surgery for inguinal hernia.
Ram, Jagat; Gupta, Nishant; Chaudhary, Manish; Verma, Neelam
2013-01-01
Background: A new emerging complication of trans-scleral fixation of posterior chamber (PC) intraocular lens (IOL) with polypropylene suture is high rates of spontaneous dislocation of the IOL due to disintegration or breakage of suture. Materials: We report a new surgical technique of trans-scleral fixation of posterior chamber intraocular lens (SF PCIOL) with steel suture to eliminate the complication of dislocation of IOL fixed with polypropylene suture in one adult and a child. Results: We successfully achieved stable fixation and good centration of IOL after SF PCIOL with steel suture in these patient having inadequate posterior capsular support. Both eyes achieved best corrected visual acuity 20/40 at 18 months follow-up. Conclusions: Steel suture is a viable option for trans-scleral fixation of posterior chamber intraocular lens. PMID:23619504
Robot-assisted bronchoplasty using continuous barbed sutures
Sarsam, Omar Matthieu; Dunning, Joel; Pochulu, Bruno
2018-01-01
We describe in this article our bronchoplastic robot-assisted techniques. This consists of using continuous barbed sutures. Our aim is to show the feasibility and the interest of using robotics and this kind of suture material for complex bronchial procedures. We report four cases in France and the UK, two wedge bronchoplasties and two sleeve bronchoplasties for central pulmonary tumors. PMID:29445589
Zhang, Tao; Wan, Chun-you; Ma, Bao-tong; Xu, Wei-guo; Mei, Xiao-long; Jia, Peng; Liu, Lei
2016-05-01
To compare clinical outcomes between two suturing methods using non absorbable materials through drilling the bone and suturing anchors for the treatment of complete rupture of the deltoid ligament. From January 2009 to January 2013, 58 hospitalized patients with ankle fracture combined with complete rupture of the deltoid ligament were treated with suturing using non absorbable materials through drilling the bone or suturing anchors. There were 29 patients who received suturing treatments using non absorbable materials through drilling the bone (Group A), including 18 males and 11 females, with an average age of (39.76 +/- 11.81) years old. According to the Lauge-Hansen classification, 12 patients had supination external rotation (SER) injuries with IV degree, 5 patients had pronation external rotation (PER) injuries with III degree, 10 patients had PER injuries with IV degrss, and 2 patients had pronation abduction injuries with III degree. There were 29 patients who received treatments with suturing using anchors (Group B), including 14 males and 15 females, with an average age of (41.79 +/- 13.28) years old. According to the Lauge-Hansen classification,9 patients had SER injuries with IV degree, 6 patients had PER injuries with III degree,13 patients had PER injuries with IV degree, and 1 patient had pronation abduction injuries with III degree. All the patients were treated with open reduction and internal fixation, as well as reconstruction of deltoid ligaments to restore the stability of the medial ankle structures. The clinical examination, imaging evaluation, American society for ankle surgery (AOFAS) ankle-hindfoot score and visual analogue scale (VAS) were used to evaluate the clinical results after operation, and the results of the two groups were compared and analyzed statistically. The follow-up duration of the 58 patients ranged from 23 to 40 months,with an average of 27.3 months. All the patients had fracture union, and the mean healing time was 12.3 weeks (ranged, 10 to 17 weeks). There were no incision complications and ankle instability. There were no significant differences between two groups in AOFAS (P=0.666) and the VAS (P=0.905). Treatments of complete rupture of the deltiod ligaments with the two suturing methods get similar good clinical effects, but the suturing using non absorbable materials through drilling the bone has several advantages such as reducing the financial burden of patients, saving social medical resources and avoiding the shortcoming in difficult removal of anchor suture.
Comparison of the cheese-wiring effects among three sutures used in rotator cuff repair
Lambrechts, Mark; Nazari, Behrooz; Dini, Arash; O'Brien, Michael J.; Heard, Wendell M. R.; Savoie, Felix H.; You, Zongbing
2014-01-01
Purpose: The goal of this study was to compare the cheese-wiring effects of three sutures with different coefficients of friction. Materials and Methods: Sixteen human cadaveric shoulders were dissected to expose the distal supraspinatus and infraspinatus muscle tendons. Three sutures were stitched through the tendons: #2 Orthocord™ suture (reference #223114, DePuy Mitek, Inc., Raynham, MA), #2 ETHIBOND* EXCEL Suture, and #2 FiberWire® suture (FiberWire®, Arthrex, Naples, FL). The sutures were pulled by cyclic axial forces from 10 to 70 N at 1 Hz for 1000 cycles through a MTS machine. The cut-through distance on the tendon was measured with a digital caliper. Results: The cut-through distance in the supraspinatus tendons (mean ± standard deviation, n = 12) were 2.9 ± 0.6 mm for #2 Orthocord™ suture, 3.2 ± 1.2 mm for #2 ETHIBOND* suture, and 4.2 ± 1.7 mm for #2 FiberWire® suture. The differences were statistically significant analyzing with analysis of variance (P = 0.047) and two-tailed Student's t-test, which showed significance between Orthocord™ and FiberWire® sutures (P = 0.026), but not significant between Orthocord™ and ETHIBOND* sutures (P = 0.607) or between ETHIBOND* and FiberWire® sutures (P = 0.103). Conclusion: The cheese-wiring effect is less in the Orthocord™ suture than in the FiberWire® suture in human cadaveric supraspinatus tendons. Clinical Relevance: Identification of sutures that cause high levels of tendon cheese-wiring after rotator cuff repair can lead to better suture selection. PMID:25258499
The Misgav Ladach method--a step forward in operative technique in obstetrics.
Fatusić, Zlatan; Kurjak, Asim; Jasarević, Edin; Hafner, Tomislav
2003-01-01
To investigate the advantage of performing cesarean section using the Misgav-Ladach method and to justify its use in everyday practice. In a prospective study we analyzed over a two year period (2000-01) cesarean sections carried out using the Misgav-Ladach method at our clinic. We compared both 550 cases of Misgav-Ladach (ML) and 100 cases of Pfannenstiel (PH) cesarean section. In the group that had undergone the Misgav-Ladach method we sutured the uterus in one layer and left the peritoneum non-sutured, and in the group who had undergone Pfennenstiel we sutured the uterus in two layers and also sutured the visceral and parietal peritoneum. In every case we analyzed: maternal age, gestational age, duration of operation, consumption of suture material, duration of hospitalization, and surgical complications. Incidence of postoperative febrile morbidity was 5.45%, in the Misgav-Ladach group compared with 13.2% in the Pfannenstiel group (p < 0.05). Local infection of the wound in the Misgav-Ladach group was found in 4.54% and in the Pfannenstiel group in 9% (p < 0.05). Mean time of extraction of the newborn in the Misgav-Ladach group was 1.25 minutes, and in the Pfannenstiel group 4.10 minutes (P < 0.05). Mean duration of operation in the Misgav-Ladach group was 10.98 min, and in the Pfannenstiel group 25 min (p < 0.05). Mean duration of hospitalization in the Misgav-Ladach group was 4.75 days, and in the Pfannenstiel group 6.32 days (p > 0.05). Mean consumption of suture material in the group Misgav-Ladach was 3.10 sutures per operation, and in the Pfannenstiel group was 9.5 sutures. Our study shows that the Misgav-Ladach method of cesarean section enables fast recovery and shorter hospitalization, and reduces the length of the operation, the incidence of surgical complication and the consumption of surgical materials.
Blaker, J J; Nazhat, S N; Boccaccini, A R
2004-01-01
A novel silver-doped bioactive glass powder (AgBG) was used to coat resorbable Vicryl (polyglactin 910) and non-resorbable Mersilk surgical sutures, thereby imparting bioactive, antimicrobial and bactericidal properties to the sutures. Stable and homogeneous coatings on the surface of the sutures were achieved using an optimised aqueous slurry-dipping technique. Dynamic mechanical analysis (DMA) was used to investigate the viscoelastic parameters of storage modulus and tandelta and thermal transitions of the as-received and composite (coated) sutures. The results generally showed that the bioactive glass coating did not affect the dynamic mechanical and thermal properties of the sutures. The in vitro bioactivity of the sutures was tested by immersion in simulated body fluid (SBF). After only 3 days of immersion in SBF, bonelike hydroxyapatite formed on the coated suture surfaces, indicating their enhanced bioactive behaviour. Resorbable sutures with bioactive coatings as fabricated here, in conjunction with 3-D textile technology, may provide attractive materials for producing 3-D scaffolds with controlled porosities for tissue engineering applications. The bactericidal properties imparted by the Ag-containing glass coating open also new opportunities for use of the composite sutures in wound healing and body wall repair.
Obturator hernia: A diagnostic challenge.
Kulkarni, Sanjeev R; Punamiya, Aditya R; Naniwadekar, Ramchandra G; Janugade, Hemant B; Chotai, Tejas D; Vimal Singh, T; Natchair, Arafath
2013-01-01
Obturator hernia is an extremely rare type of hernia with relatively high mortality and morbidity. Its early diagnosis is challenging since the signs and symptoms are non specific. Here in we present a case of 70 years old women who presented with complaints of intermittent colicky abdominal pain and vomiting. Plain radiograph of abdomen showed acute dilatation of stomach. Ultrasonography showed small bowel obstruction at the mid ileal level with evidence of coiled loops of ileum in pelvis. On exploration, Right Obstructed Obturator hernia was found. The obstructed Intestine was reduced and resected and the obturator foramen was closed with simple sutures. Postoperative period was uneventful. Obturator hernia is a rare pelvic hernia and poses a diagnostic challenge. Obturator hernia occurs when there is protrusion of intra-abdominal contents through the obturator foramen in the pelvis. The signs and symptoms are non specific and generally the diagnosis is made during exploration for the intestinal obstruction, one of the four cardinal features. Others are pain on the medial aspect of thigh called as Howship Rombergs sign, repeated attacks of Intestinal Obstruction and palpable mass on the medial aspect of thigh. Obturator hernia is a rare but significant cause of intestinal obstruction especially in emaciated elderly woman and a diagnostic challenge for the Doctors. CT scan is valuable to establish preoperative diagnosis. Surgery either open or laproscopic, is the only treatment. The need for the awareness is stressed and CT scan can be helpful. Copyright © 2013 Surgical Associates Ltd. Published by Elsevier Ltd. All rights reserved.
Current manufacturing processes of drug-eluting sutures.
Champeau, Mathilde; Thomassin, Jean-Michel; Tassaing, Thierry; Jérôme, Christine
2017-11-01
Drug-eluting sutures represent the next generation of surgical sutures since they fulfill their mechanical functions but also deliver the drug in their vicinity after implantation. These implants are produced by a variety of manufacturing processes. Drug-eluting sutures represent the next generation of surgical sutures since they fulfill their mechanical functions but also deliver the drug in their vicinity after implantation. These implants are produced by a variety of manufacturing processes. Two general approaches can be followed: (i) the ones that add the API into the material during the manufacturing process of the suture and (ii) the ones that load the API to an already manufactured suture. Areas covered: This review provides an overview of the current manufacturing processes for drug-eluting suture production and discusses their benefits and drawbacks depending on the type of drugs. The mechanical properties and the drug delivery profile of drug-eluting sutures are highlighted since these implants must fulfill both criteria. Expert opinion: For limited drug contents, melt extrusion and electrospinning are the emerging processes since the drug is added during the suture manufacture process. Advantageously, the drug release profile can be tuned by controlling the processing parameters specific to each process and the composition of the drug-containing polymer. If high drug content is targeted, the coating or grafting of a drug layer on a pre-manufactured suture allows for preservation of the tensile strength requirements of the suture.
Zhang, Gangqiang; Ren, Tianhui; Lette, Walter; Zeng, Xiangqiong; van der Heide, Emile
2017-10-01
Nowadays there is a wide variety of surgical sutures available in the market. Surgical sutures have different sizes, structures, materials and coatings, whereas they are being used for various surgeries. The frictional performances of surgical sutures have been found to play a vital role in their functionality. The high friction force of surgical sutures in the suturing process may cause inflammation and pain to the person, leading to a longer recovery time, and the second trauma of soft or fragile tissue. Thus, the investigation into the frictional performance of surgical suture is essential. Despite the unquestionable fact, little is actually known on the friction performances of surgical suture-tissue due to the lack of appropriate test equipment. This study presents a new penetration friction apparatus (PFA) that allowed for the evaluation of the friction performances of various surgical needles and sutures during the suturing process, under different contact conditions. It considered the deformation of tissue and can realize the puncture force measurements of surgical needles as well as the friction force of surgical sutures. The developed PFA could accurately evaluate and understand the frictional behaviour of surgical suture-tissue in the simulating clinical conditions. The forces measured by the PFA showed the same trend as that reported in literatures. Copyright © 2017 Elsevier Ltd. All rights reserved.
The effect of an air knot on surgical knot integrity.
Shatkin-Margolis, Abigail; Kow, Nathan; Patonai, Nicolas; Boin, Michael; Muffly, Tyler M
2015-01-01
Surgical trainees may tie air knots, which have a questionable tensile strength and rate of untying. The purpose of this study was to determine the effect of an air knot on knot integrity. The 5 suture materials tested were 0-0 gauge coated polyethylene, polyglyconate, glycolide/lactide, polypropylene, and silk. The suture was tied between 2 hex screws 50 mm on center. The strands were tied using 5 square throws, and the knot tails were cut at 3-mm length. To create a standardized air knot, a round common nail measuring 3 mm in diameter was inserted between throws before tying square throw #3. The suture loop was positioned around the upper and lower hooks of the tensiometer so the location of the knot was roughly equidistant from the hooks. Ultimately, either the loop broke or the knot slipped. At that time, the peak tensile force as well as the outcome of the knot were recorded. A total of 480 knots were tied. The presence of an air knot significantly lowered the tension at knot failure in the glycolide/lactide (P = 0.0003), polypropylene (P = 0.0005), and silk (P = 0.0001) knot configurations. Air knots had the same integrity as surgical knots when coated polyethylene and polyglyconate suture were used. Linear regression was performed and identified both suture material (P < 0.0001) and presence of an air knot (P < 0.0001) to be independently associated with a lower tension at failure. Under laboratory conditions, an air knot may contribute to a lower tensile strength at failure for certain suture materials.
Mechanical model of suture joints with fibrous connective layer
NASA Astrophysics Data System (ADS)
Miroshnichenko, Kateryna; Liu, Lei; Tsukrov, Igor; Li, Yaning
2018-02-01
A composite model for suture joints with a connective layer of aligned fibers embedded in soft matrix is proposed. Based on the principle of complementary virtual work, composite cylinder assemblage (CCA) approach and generalized self-consistent micro-mechanical models, a hierarchical homogenization methodology is developed to systematically quantify the synergistic effects of suture morphology and fiber orientation on the overall mechanical properties of sutures. Suture joints with regular triangular wave-form serve as an example material system to apply this methodology. Both theoretical and finite element mechanical models are developed and compared to evaluate the overall normal stiffness of sutures as a function of wavy morphology of sutures, fiber orientation, fiber volume fraction, and the mechanical properties of fibers and matrix in the interfacial layer. It is found that generally due to the anisotropy-induced coupling effects between tensile and shear deformation, the effective normal stiffness of sutures is highly dependent on the fiber orientation in the connective layer. Also, the effective shear modulus of the connective layer and the stiffness ratio between the fiber and matrix significantly influence the effects of fiber orientation. In addition, optimal fiber orientations are found to maximize the stiffness of suture joints.
Ergin, Ömer Naci; Demirel, Mehmet; Özmen, Emre
2017-01-01
Rupture of the Achilles' tendon is a common injury occurring particularly in middle-aged men due to sports trauma. Operative treatment is preferred generally due to lower risk of re-rupture. Possible complications of the operation include suture granulomas. Suture granulomas might represent a foreign body reaction, which itself is the end-stage response of the inflammatory wound-healing process to biomaterials. It may occur with both absorbable and non-absorbable suture materials such as silk in our case. The aim of this study is to present a case of a delayed foreign body reaction 30 years after open repair of the Achilles tendon with silk sutures. Our case is a 38-year-old male who presented to our outpatient clinic with complaints of swelling and pain around the posterior region of the ankle for the past 3 months. He had a history of open Achilles tendon repair at the age of 3 at the site of complaints. Physical examination was positive for a mass under the incision scar. Magnetic resonance imaging report was positive for a granulomatosis formation. The patient was booked for an operation to remove the mass. Suture granuloma represents a tissue reaction against the suture material. Orthopedic literature is sparse for such cases and case reports. Both because of its rarity in orthopedic literature and the amount of time between the surgery and reaction, our report is a valuable addition to the literature.
Chong, Alexander Cm; Prohaska, Daniel J; Bye, Brian P
2017-05-01
With arthroscopic techniques being used, the importance of knot tying has been examined. Previous literature has examined the use of reversing half-hitches on alternating posts (RHAPs) on knot security. Separately, there has been research regarding different suture materials commonly used in the operating room. The specific aim of this study was to validate the effect of different stacked half-hitch configuration and different braided suture materials on arthroscopic knot integrity. Three different suture materials tied with five different RHAPs in arthroscopic knots were compared. A single load-to-failure test was performed and the mean ultimate clinical failure load was obtained. Significant knot holding strength improvement was found when one half-hitch was reversed as compared to baseline knot. When two of the half-hitches were reversed, there was a greater improvement with all knots having a mean ultimate clinical failure load greater than 150 newtons (N). Comparison of the suture materials demonstrated a higher mean ultimate clinical failure load when Force Fiber ® was used and at least one half-hitch was reversed. Knots tied with either Force Fiber ® or Orthocord ® showed 0% chance of knot slippage while knots tied with FiberWire ® or braided fishing line had about 10 and 30% knot slippage chances, respectively. A significant effect was observed in regards to both stacked half-hitch configuration and suture materials used on knot loop and knot security. Caution should be used with tying three RHAPs in arthroscopic surgery, particularly with a standard knot pusher and arthroscopic cannulas. The findings of this study indicated the importance of three RHAPs in performing arthroscopic knot tying and provided evidence regarding discrepancies of maximum clinical failure loads observed between orthopaedic surgeons, thereby leading to better surgical outcomes in the future.
Patel, Sunil V; Paskar, David D; Nelson, Richard L; Vedula, Satyanarayana S; Steele, Scott R
2017-11-03
Surgeons who perform laparotomy have a number of decisions to make regarding abdominal closure. Material and size of potential suture types varies widely. In addition, surgeons can choose to close the incision in anatomic layers or mass ('en masse'), as well as using either a continuous or interrupted suturing technique, of which there are different styles of each. There is ongoing debate as to which suturing techniques and suture materials are best for achieving definitive wound closure while minimising the risk of short- and long-term complications. The objectives of this review were to identify the best available suture techniques and suture materials for closure of the fascia following laparotomy incisions, by assessing the following comparisons: absorbable versus non-absorbable sutures; mass versus layered closure; continuous versus interrupted closure techniques; monofilament versus multifilament sutures; and slow absorbable versus fast absorbable sutures. Our objective was not to determine the single best combination of suture material and techniques, but to compare the individual components of abdominal closure. On 8 February 2017 we searched CENTRAL, MEDLINE, Embase, two trials registries, and Science Citation Index. There were no limitations based on language or date of publication. We searched the reference lists of all included studies to identify trials that our searches may have missed. We included randomised controlled trials (RCTs) that compared suture materials or closure techniques, or both, for fascial closure of laparotomy incisions. We excluded trials that compared only types of skin closures, peritoneal closures or use of retention sutures. We abstracted data and assessed the risk of bias for each trial. We calculated a summary risk ratio (RR) for the outcomes assessed in the review, all of which were dichotomous. We used random-effects modelling, based on the heterogeneity seen throughout the studies and analyses. We completed subgroup analysis planned a priori for each outcome, excluding studies where interventions being compared differed by more than one component, making it impossible to determine which variable impacted on the outcome, or the possibility of a synergistic effect. We completed sensitivity analysis, excluding trials with at least one trait with high risk of bias. We assessed the quality of evidence using the GRADEpro guidelines. Fifty-five RCTs with a total of 19,174 participants met the inclusion criteria and were included in the meta-analysis. Included studies were heterogeneous in the type of sutures used, methods of closure and patient population. Many of the included studies reported multiple comparisons.For our primary outcome, the proportion of participants who developed incisional hernia at one year or more of follow-up, we did not find evidence that suture absorption (absorbable versus non-absorbable sutures, RR 1.07, 95% CI 0.86 to 1.32, moderate-quality evidence; or slow versus fast absorbable sutures, RR 0.81, 95% CI 0.63 to 1.06, moderate-quality evidence), closure method (mass versus layered, RR 1.92, 95% CI 0.58 to 6.35, very low-quality evidence) or closure technique (continuous versus interrupted, RR 1.01, 95% CI 0.76 to 1.35, moderate-quality evidence) resulted in a difference in the risk of incisional hernia. We did, however, find evidence to suggest that monofilament sutures reduced the risk of incisional hernia when compared with multifilament sutures (RR 0.76, 95% CI 0.59 to 0.98, I 2 = 30%, moderate-quality evidence).For our secondary outcomes, we found that none of the interventions reduced the risk of wound infection, whether based on suture absorption (absorbable versus non-absorbable sutures, RR 0.99, 95% CI 0.84 to 1.17, moderate-quality evidence; or slow versus fast absorbable sutures, RR 1.16, 95% CI 0.85 to 1.57, moderate-quality evidence), closure method (mass versus layered, RR 0.93, 95% CI 0.67 to 1.30, low-quality evidence) or closure technique (continuous versus interrupted, RR 1.13, 95% CI 0.96 to 1.34, moderate-quality evidence).Similarily, none of the interventions reduced the risk of wound dehiscence whether based on suture absorption (absorbable versus non-absorbable sutures, RR 0.78, 95% CI 0.55 to 1.10, moderate-quality evidence; or slow versus fast absorbable sutures, RR 1.55, 95% CI 0.92 to 2.61, moderate-quality evidence), closure method (mass versus layered, RR 0.69, 95% CI 0.31 to 1.52, moderate-quality evidence) or closure technique (continuous versus interrupted, RR 1.21, 95% CI 0.90 to 1.64, moderate-quality evidence).Absorbable sutures, compared with non-absorbable sutures (RR 0.49, 95% CI 0.26 to 0.94, low-quality evidence) reduced the risk of sinus or fistula tract formation. None of the other comparisons showed a difference (slow versus fast absorbable sutures, RR 0.88, 95% CI 0.05 to 16.05, very low-quality evidence; mass versus layered, RR 0.49, 95% CI 0.15 to 1.62, low-quality evidence; continuous versus interrupted, RR 1.51, 95% CI 0.64 to 3.61, very low-quality evidence). Based on this moderate-quality body of evidence, monofilament sutures may reduce the risk of incisional hernia. Absorbable sutures may also reduce the risk of sinus or fistula tract formation, but this finding is based on low-quality evidence.We had serious concerns about the design or reporting of several of the 55 included trials. The comparator arms in many trials differed by more than one component, making it impossible to attribute differences between groups to any one component. In addition, the patient population included in many of the studies was very heterogeneous. Trials included both emergency and elective cases, different types of disease pathology (e.g. colon surgery, hepatobiliary surgery, etc.) or different types of incisions (e.g. midline, paramedian, subcostal).Consequently, larger, high-quality trials to further address this clinical challenge are warranted. Future studies should ensure that proper randomisation and allocation techniques are performed, wound assessors are blinded, and that the duration of follow-up is adequate. It is important that only one type of intervention is compared between groups. In addition, a homogeneous patient population would allow for a more accurate assessment of the interventions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Walker, Ricardo W.; Brown, Richard S.; Deters, Katherine A.
Ultraviolet radiation (UVR) can be used as a tool to disinfect surgery tools used for implanting transmitters into fish. However, the use of UVR could possibly degrade monofilament suture material used to close surgical incisions. This research examined the effect of UVR on monofilament sutures to determine if they were compromised and negatively influenced tag and suture retention, incision openness, or tissue reaction. Eighty juvenile Chinook salmon Oncorhynchus tshawytscha were surgically implanted with an acoustic transmitter and a passive integrated transponder. The incision was closed with a single stitch of either a suture exposed to 20 doses of UV radiationmore » (5 minute duration per dose) or a new, sterile suture. Fish were then held for 28 d and examined under a microscope at day 7, 14, 21 and 28 for incision openness, ulceration, redness, and the presence of water mold. There was no significant difference between treatments for incision openness, redness, ulceration or the presence of water mold on any examination day. On day 28 post-surgery, there were no lost sutures; however, 2 fish lost their transmitters (one from each treatment). The results of this study do not show any differences in negative influences such as tissue response, suture retention or tag retention between a new sterile suture and a suture disinfected with UVR.« less
Baums, M H; Buchhorn, G H; Gilbert, F; Spahn, G; Schultz, W; Klinger, H-M
2010-09-01
This experimental study aimed to compare the load-to-failure rate and stiffness of single- versus double-row suture techniques for repairing rotator cuff lesions using two different suture materials. Additionally, the mode of failure of each repair was evaluated. In 32 sheep shoulders, a standardized tear of the infraspinatus tendon was created. Then, n = 8 specimen were randomized to four repair methods: (1) Double-row Anchor Ethibond coupled with polyester sutures, USP No. 2; (2) Double-Row Anchor HiFi with polyblend polyethylene sutures, USP No. 2; (3) Single-Row Anchor Ethibond coupled with braided polyester sutures, USP No. 2; and (4) Single-Row Anchor HiFi with braided polyblend polyethylene sutures, USP No. 2. Arthroscopic Mason-Allen stitches were placed (single-row) and combined with medial horizontal mattress stitches (double-row). All specimens were loaded to failure at a constant displacement rate on a material testing machine. Group 4 showed lowest load-to-failure result with 155.7 +/- 31.1 N compared to group 1 (293.4 +/- 16.1 N) and group 2 (397.7 +/- 7.4 N) (P < 0.001). Stiffness was highest in group 2 (162 +/- 7.3 N/mm) and lowest in group 4 (84.4 +/- 19.9 mm) (P < 0.001). In group 4, the main cause of failure was due to the suture cutting through the tendon (n = 6), a failure case observed in only n = 1 specimen in group 2 (P < 0.001). A double-row technique combined with arthroscopic Mason-Allen/horizontal mattress stitches provides high initial failure strength and may minimize the risk of the polyethylene sutures cutting through the tendon in rotator cuff repair when a single load force is used.
Experimental evaluation of clinical colon anastomotic leakage.
Pommergaard, Hans-Christian
2014-03-01
Colorectal anastomotic leakage remains a frequent and serious complication in gastrointestinal surgery. Patient and procedure related risk factors for anastomotic leakage have been identified. However, the responsible pathophysiological mechanisms are still unknown. Among these, ischemia and insufficient surgical technique have been suggested to play a central role. Animal models are valuable means to evaluate pathophysiological mechanisms and may be used to test preventive measures aiming at reducing the risk of anastomotic leakage, such as external anastomotic coating. The aim of this thesis was to: Clarify the best suited animal to model clinical anastomotic leakage in humans; Create animal models mimicking anastomotic leakage in humans induced by insufficient surgical technique and tissue ischemia; Determine the best suited coating materials to prevent anastomotic leakage. This study is a systematic review using the databases MEDLINE and Rex. MEDLINE was searched up to October 2010 to identify studies on experimental animal models of clinical colon anastomotic leakage. From the Rex database, textbooks on surgical aspects as well as gastrointestinal physiology and anatomy of experimental animals were identified. The results indicated that the mouse and the pig are the best suited animals to evaluate clinical anastomotic leakage. However, the pig model is less validated and more costly to use compared with the mouse. Most frequently, rats are used as models. However, extreme interventions are needed to create clinical leakage in these animals. The knowledge from this study formed the basis for selecting the animal species most suited for the models in the next studies. STUDY 2: In this experimental study, technically insufficient colonic anastomoses were performed in 110 C57BL/6 mice. The number of sutures in the intervention group was reduced to produce a suitable leakage rate. Moreover, the analgesia and suture material were changed in order to optimize the model. In the final experiment, the four-suture anastomoses resulted in a 40% leakage rate in the intervention groups, whereas the eight-suture control anastomoses had a 0% leakage rate. Furthermore, the use of absorbable suture together with voluntarily ingested Temgesic in chocolate spread as analgesic regimen were feasible. This model may be used to test the leakage reducing potential of coating materials. STUDY 3: This experimental study used 53 C57BL/6 mice, in which sufficient eight-suture anastomoses were created. By using bipolar electro-cautery, blood supply was reduced in a stepwise manner to create anastomotic leakage as a result of ischemia. The study showed that reduced blood supply led to large bowel obstruction instead of clinical leakage. However, anastomotic breaking strength was reduced in the ischemic anastomoses. STUDY 4: In this systematic review MEDLINE, Embase and Cinahl were searched up to September 2011 to identify studies evaluating external coating of colonic anastomoses. Most studies were experimental, in which designs were not comparable and many results were contradictory. In a clinical study, a non-significant benefit of fibrin sealant was found. Based on the available clinical and experimental data it was concluded that the fibrin-based sealants, such as Tisseel and Tachosil, and polyethylene glycols may be beneficial. However, further experimental and clinical studies are needed before routine clinical use can be recommended. The studies in this thesis may be valuable for the experimental research field of clinical anastomotic leakage. The model of technical insufficiency has been improved and is now thoroughly validated. If used by researchers worldwide, comparison of results is possible. Pure ischemia/anoxia may be too simple an approach to create a clinical leakage model. Thus, future models could focus on multiple risk factors. Conclusively, large-scale clinical multicenter studies are needed to definitively evaluate whether coating of colorectal anastomoses may reduce the leakage rate.
Zellner, Eric M; Hedlund, Cheryl S; Kraus, Karl H; Burton, Andrew F; Kieves, Nina R
2016-06-15
OBJECTIVE To compare suture placement time, tension at skin separation and suture line failure, and mode of failure among 4 suture patterns. DESIGN Randomized trial. SAMPLE 60 skin specimens from the pelvic limbs of 30 purpose-bred Beagles. PROCEDURES Skin specimens were harvested within 2 hours after euthanasia and tested within 6 hours after harvest. An 8-cm incision was made in each specimen and sutured with 1 of 4 randomly assigned suture patterns (simple interrupted, cruciate, intradermal, or subdermal). Suture placement time and percentage of skin apposition were evaluated. Specimens were mounted in a calibrated material testing machine and distracted until suture line failure. Tensile strength at skin-edge separation and suture-line failure and mode of failure were compared among the 4 patterns. RESULTS Mean suture placement time for the cruciate pattern was significantly less than that for other patterns. Percentage of skin apposition did not differ among the 4 patterns. Mean tensile strength at skin-edge separation and suture-line failure for the simple interrupted and cruciate patterns were significantly higher than those for the intradermal and subdermal patterns. Mean tensile strength at skin-edge separation and suture-line failure did not differ significantly between the intradermal and subdermal patterns or the simple interrupted and cruciate patterns. The primary mode of failure for the simple interrupted pattern was suture breakage, whereas that for the cruciate, intradermal, and subdermal patterns was tissue failure. CONCLUSIONS AND CLINICAL RELEVANCE Results suggested external skin sutures may be preferred for closure of incisions under tension to reduce risk of dehiscence.
Postl, L K; Ahrens, P; Beirer, M; Crönlein, M; Imhoff, A B; Foehr, P; Burgkart, R; Braun, C; Kirchhoff, Chlodwig
2016-08-01
Osteoporosis is a highly focused issue in current scientific research and clinical treatment. Especially in rotator cuff repair, the low bone quality of patients suffering from osteoporosis is an important issue. In this context, non-biological solutions using PMMA for anchor augmentation have been developed in the recent past. The aim of this study was to evaluate whether augmentation of suture anchors using bio-absorbable osteoconductive fiber-reinforced calcium phosphate results in improved failure load of suture anchors as well. Altogether 24 suture anchors (Corkscrew FT 1 Suture Anchors, Arthrex, Naples, FL, USA) were evaluated by applying traction until pullout in 12 paired fresh frozen human cadaver humeri using a servo-hydraulic testing machine. Inclusion criteria were an age of more than 64 years, a macroscopically intact RC and an intact bone. The anchors were evaluated at the anterolateral and posteromedial aspect of the greater tuberosity. 12 suture anchors were augmented and 12 suture anchors were conventionally inserted. The failure load was significantly enhanced by 66.8 % by the augmentation method. The fiber-reinforced calcium phosphate could be easily injected and applied. The bio-absorbable cement in this study could be a promising augmentation material for RC reconstructions, but further research is necessary-the material has to be evaluated in vivo.
Sundararaj, Sharath; Slusarewicz, Paul; Brown, Matt; Hedman, Thomas
2017-11-01
The most common mode of surgical repair of ruptured tendons and ligaments involves the use of sutures for reattachment. However, there is a high incidence of rerupture and repair failure due to pulling out of the suture material from the damaged connective tissue. The main goal of this research was to achieve a localized delivery of crosslinking agent genipin (GP) from rapid-release biodegradable coatings on sutures, for strengthening the repair of ruptured connective tissue. Our hypothesis is that GP released from the suture coating will lead to exogenous crosslinking of native connective tissue resulting in beneficial effects on clinically relevant mechanical parameters such as tear resistance, tissue strength, and energy required to rupture the tissue (toughness). Sutures were successfully coated with a biodegradable polymer layer loaded with the crosslinking agent genipin, without compromising the mechanical properties of the suture. The rapid-release of genipin was achieved under both in vitro and ex vivo conditions. Exogenous crosslinking using these genipin releasing sutures was demonstrated using equine tendons. The tendons treated with genipin releasing sutures showed significant improvement in failure load, energy required for pull-out failure, and stiffness. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 2199-2205, 2017. © 2016 Wiley Periodicals, Inc.
Digital multimedia instruction enhances teaching oral and maxillofacial suturing.
Weaver, J M; Lu, Mei; McCloskey, K L; Herndon, E S; Tanaka, W
2009-12-01
To develop digital multimedia instruction on intraoral suturing. A DVD was developed to describe instruments, materials, and techniques. Two groups of dental students were asked to close an incision in a simulated model. One used written materials only and another used additional DVD. The performance was evaluated using 10 grading criteria. Students who used the DVD performed better than students who did not. This DVD could be used widely in teaching dental students.
Hakamada, Kenichi; Narumi, Shunji; Toyoki, Yoshikazu; Nara, Masaki; Ishido, Kenosuke; Miura, Takuya; Kubo, Norihito; Sasaki, Mutsuo
2008-01-01
AIM: To clarify the usefulness of a new method for performing a pancreaticojejunostomy by using a fast-absorbable suture material irradiated polyglactin 910, and a temporary stent tube for a narrow pancreatic duct with a soft pancreatic texture. METHODS: Among 63 consecutive patients with soft pancreas undergoing a pancreaticoduodenectomy from 2003 to 2006, 35 patients were treated with a new reconstructive method. Briefly, after the pancreatic transaction, a stent tube was inserted into the lumen of the pancreatic duct and ligated with it by a fast-absorbable suture. Another tip of the stent tube was introduced into the intestinal lumen at the jejunal limb, where a purse-string suture was made by another fast-absorbable suture to roughly fix the tube. The pancreaticojejunostomy was completed by ligating two fast-absorbable sutures to approximate the ductal end and the jejunal mucosa, and by adding a rough anastomosis between the pancreatic parenchyma and the seromuscular layer of the jejunum. The initial surgical results with this method were retrospectively compared with those of the 28 patients treated with conventional duct-to-mucosa anastomosis. RESULTS: The incidences of postoperative morbidity including pancreatic fistula were comparable between the two groups (new; 3%-17% vs conventional; 7%-14% according to the definitions). There was no mortality and re-admission. Late complications were also rarely seen. CONCLUSION: A pancreaticojejunostomy using an irradiated polyglactin 910 suture material and a temporary stent is easy to perform and is feasible even in cases with a narrow pancreatic duct and a normal soft pancreas. PMID:18286692
Nickel-titanium wire as a flexor tendon suture material: an ex vivo study.
Karjalainen, T; Göransson, H; Viinikainen, A; Jämsä, T; Ryhänen, J
2010-07-01
Nickel-titanium shape memory alloy (NiTi) is a new suture material that is easy to handle, is strong, and biocompatible. The purpose of this study was to evaluate the material properties and biomechanical behaviour of 150 microm and 200 microm NiTi wires in flexor tendon repair. Braided polyester (4-0 Ethibond) was used as control. Fifty fresh-frozen porcine flexor tendons were repaired using the Pennington modification of the Kessler repair or a double Kessler technique. NiTi wires were stiffer and reached higher tensile strength compared to braided polyester suture. Repairs with 200 microm NiTi wire had a higher yield force, ultimate force and better resistance to gapping than 4-0 braided polyester repairs. Repairs made with 200 microm NiTi wire achieved higher stiffness and ultimate force than repairs made with 150 microm NiTi wire.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Deters, Katherine A.; Brown, Richard S.; Carter, Kathleen M.
2010-05-01
This study assessed performance of seven suture types in subyearling Chinook salmon Oncorhynchus tshawytscha implanted with acoustic microtransmitters. Nonabsorbable (Ethilon) and absorbable (Monocryl) monofilament and nonabsorbable (Nurolon, silk) and absorbable (Vicryl, Vicryl Plus, Vicryl Rapide) braided sutures were used to close incisions in Chinook salmon. Monocryl exhibited greater suture retention than all other suture types 7 d after surgery. Both monofilament suture types were retained better than all braided suture types at 14 d. Incision openness and tag retention did not differ among suture types. Wound inflammation was similar for Ethilon, Monocryl, and Nurolon at 7 d. Wound ulceration wasmore » lower for Ethilon, Monocryl, and Nurolon than for all other suture types at 14 d post-surgery. Fish held in 12°C water had more desirable post-surgery healing characteristics (i.e., higher suture and tag retention and lower incision openness, wound inflammation, and ulceration) at 7 and 14 d after surgery than those held in 17°C water. The effect of surgeon was a significant predictor for all response variables at 7 d. This result emphasizes the importance of including surgeon as a variable in telemetry study analyses when multiple surgeons are used. Monocryl performed better with regard to post-surgery healing characteristics in the study fish. The overall results support the conclusion that Monocryl is the best suture material to close incisions created during surgical implantation of acoustic microtransmitters in subyearling Chinook salmon.« less
Shear lag sutures: Improved suture repair through the use of adhesives
Linderman, Stephen W.; Kormpakis, Ioannis; Gelberman, Richard H.; Birman, Victor; Wegst, Ulrike G. K.; Genin, Guy M.; Thomopoulos, Stavros
2015-01-01
Suture materials and surgical knot tying techniques have improved dramatically since their first use over five millennia ago. However, the approach remains limited by the ability of the suture to transfer load to tissue at suture anchor points. Here, we predict that adhesive-coated sutures can improve mechanical load transfer beyond the range of performance of existing suture methods, thereby strengthening repairs and decreasing the risk of failure. The mechanical properties of suitable adhesives were identified using a shear lag model. Examination of the design space for an optimal adhesive demonstrated requirements for strong adhesion and low stiffness to maximize the strength of the adhesive-coated suture repair construct. To experimentally assess the model, we evaluated single strands of sutures coated with highly flexible cyanoacrylates (Loctite 4903 and 4902), cyanoacrylate (Loctite QuickTite Instant Adhesive Gel), rubber cement, rubber/gasket adhesive (1300 Scotch-Weld Neoprene High Performance Rubber & Gasket Adhesive), an albumin-glutaraldehyde adhesive (BioGlue), or poly(dopamine). As a clinically relevant proof-of-concept, cyanoacrylate-coated sutures were then used to perform a clinically relevant flexor digitorum tendon repair in cadaver tissue. The repair performed with adhesive-coated suture had significantly higher strength compared to the standard repair without adhesive. Notably, cyanoacrylate provides strong adhesion with high stiffness and brittle behavior, and is therefore not an ideal adhesive for enhancing suture repair. Nevertheless, the improvement in repair properties in a clinically relevant setting, even using a non-ideal adhesive, demonstrates the potential for the proposed approach to improve outcomes for treatments requiring suture fixation. Further study is necessary to develop a strongly adherent, compliant adhesive within the optimal design space described by the model. PMID:26022966
Cho, Byung-Ki; Kim, Yong-Min; Park, Kyoung-Jin; Park, Ji-Kang; Kim, Do-Kyoon
2015-02-01
There are various ligament reattachment techniques for the modified Brostrom procedure. There have been few comparative studies on recently developed techniques. This prospective study was performed to compare the functional outcomes of 2 different ligament reattachment techniques using suture anchors. We furthermore evaluated the cost-effectiveness of the suture bridge technique. Forty-five amateur athletes under 30 years of age were followed for more than 2 years. Twenty-four procedures with the suture anchor technique and 21 procedures with the suture bridge technique were performed by one surgeon. The functional evaluation consisted of the American Orthopaedic Foot & Ankle Society (AOFAS) score, Foot and Ankle Outcome Score (FAOS), Karlsson score, Sefton grading system, and the period to return to various forms of exercise (jogging, spurt running, jumping, one leg standing for >1 minute, walking on uneven ground, and going down stairs). Measurement of talar tilt angle and anterior talar translation was obtained from stress radiographs to evaluate mechanical stability. There were no significant differences on AOFAS score, FAOS, Karlsson score, Sefton grade, and stress radiographs. There were no significant differences on the return to exercises, except for jumping. As the most common complication, there were 3 cases of skin irritation by suture materials in the suture anchor group and 2 cases of intraoperative breakage of the suture anchor in suture bridge group. Both ligament reattachment techniques using suture anchors showed similar functional outcomes. Considering the additional medical expenses incurred by more suture anchors, the modified Brostrom procedure using the suture bridge technique had low cost-effectiveness. Proper indication and clinical usefulness of suture bridge technique for chronic ankle instability will be addressed in further studies. Level II, prospective comparative study. © The Author(s) 2014.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Woodley, Christa M.; Wagner, Katie A.; Bryson, Amanda J.
Acoustic transmitters used in survival and telemetry studies are often surgically implanted in fish. While this is a well-established method, it has the potential to affect health, behavior, and survival, thus affecting study results. Much research has been done to try to minimize the harmful effects caused by the transmitter and tagging process. In 2009, we first investigated the use of a bi-directional knotless (barbed) suture material in juvenile Chinook salmon (Oncorhynchus tshawytscha). We found that it resulted in higher tag retention than the simple interrupted suture pattern; however, the occurrence of ulceration and redness increased. The objective of thismore » study was to refine the suturing patterns of the bi-directional knotless suture and retest suture performance in juvenile Chinook salmon. We tested the bi-directional suture using 3 different suture patterns and two needle types: 6-Point (12-mm needle circumference), Wide “N” (12-mm needle circumference), Wide “N” Knot 12 (12-mm needle circumference), and Wide “N” Knot 18 (18-mm needle circumference).« less
Management of obstructed defecation.
Podzemny, Vlasta; Pescatori, Lorenzo Carlo; Pescatori, Mario
2015-01-28
The management of obstructed defecation syndrome (ODS) is mainly conservative and mainly consists of fiber diet, bulking laxatives, rectal irrigation or hydrocolontherapy, biofeedback, transanal electrostimulation, yoga and psychotherapy. According to our experience, nearly 20% of the patients need surgical treatment. If we consider ODS an "iceberg syndrome", with "emerging rocks", rectocele and rectal internal mucosal prolapse, that may benefit from surgery, at least two out of ten patients also has "underwater rocks" or occult disorders, such as anismus, rectal hyposensation and anxiety/depression, which mostly require conservative treatment. Rectal prolapse excision or obliterative suture, rectocele and/or enterocele repair, retrograde Malone's enema and partial myotomy of the puborectalis muscle are effective in selected cases. Laparoscopic ventral sacral colporectopexy may be an effective surgical option. Stapled transanal rectal resection may lead to severe complications. The Transtar procedure seems to be safer, when dealing with recto-rectal intussusception. A multidisciplinary approach to ODS provides the best results.
Management of obstructed defecation
Podzemny, Vlasta; Pescatori, Lorenzo Carlo; Pescatori, Mario
2015-01-01
The management of obstructed defecation syndrome (ODS) is mainly conservative and mainly consists of fiber diet, bulking laxatives, rectal irrigation or hydrocolontherapy, biofeedback, transanal electrostimulation, yoga and psychotherapy. According to our experience, nearly 20% of the patients need surgical treatment. If we consider ODS an “iceberg syndrome”, with “emerging rocks”, rectocele and rectal internal mucosal prolapse, that may benefit from surgery, at least two out of ten patients also has “underwater rocks” or occult disorders, such as anismus, rectal hyposensation and anxiety/depression, which mostly require conservative treatment. Rectal prolapse excision or obliterative suture, rectocele and/or enterocele repair, retrograde Malone’s enema and partial myotomy of the puborectalis muscle are effective in selected cases. Laparoscopic ventral sacral colporectopexy may be an effective surgical option. Stapled transanal rectal resection may lead to severe complications. The Transtar procedure seems to be safer, when dealing with recto-rectal intussusception. A multidisciplinary approach to ODS provides the best results. PMID:25632177
Mizuno, A; Nakamura, Y; Takayasu, H; Saitoh, H
1993-05-01
Successful repair of a 8-month-old girl with polysplenia was reported. The cardiovascular anomalies were TAPVC (II b), incomplete ECD, interruption of inferior vena cava with hemiazygos continuation, bilateral superior vena cava, and left superior vena cava draining into the coronary sinus. Cardiopulmonary bypass was established with ascending aortic perfusion and caval cannulation. A left superior vena cava was directly cannulated after establishing partial bypass. In this case the left pulmonary vein drained into the right atrium near the orifice of the coronary sinus, so the atrial septal flap was made and sutured between the orifice of the left pulmonary vein and the coronary sinus in order to avoid late pulmonary vein obstruction. Then, atrium was separated by an intraatrial baffle which was sutured to the atrial septal flap. Recently, it becomes possible to surgical repair of polysplenia syndrome according to the advancements of the diagnostic methods, cardiopulmonary bypass, and the technique of the open heart surgery.
Lessons learned from laser tissue soldering and fibrin glue pyeloplasty in an in vivo porcine model.
Barrieras, D; Reddy, P P; McLorie, G A; Bägli, D; Khoury, A E; Farhat, W; Lilge, L; Merguerian, P A
2000-09-01
We compared sutured pyeloplasty to 2 newer techniques of tissue anastomosis, including laser soldered pyeloplasty using a diode laser with 50% albumin solder mixed with indocyanine green and fibrin glue. We performed 53 pyeloplasties in 50 pigs using suture, laser or fibrin glue. In the immediate group anastomotic leak pressure was measured immediately postoperatively, and then animals were euthanized. At 1, 3 and 4 weeks postoperatively a pressure flow study at 10 cc per minute in cm. H2O was performed, and tissue was sent for histological and collagen content analysis. In the immediate studies laser soldering achieved a significantly higher mean anastomotic leak pressure (50.5 +/- 15.1 cm. H2O) than sutured (17.3 +/- 5.4) or fibrin glued (3.5 +/- 1.5) repairs. In the 1, 2 and 4-week studies animals in the sutured pyeloplasty group had no complications, and all pressure flow studies except 1 were normal. However, in the laser soldered groups we observed 8 urinomas in 19 animals, and most occurred during the first part of our study. This complication was prevented by stopping urine flow at the anastomotic site at laser irradiation and by improving application of the solder. Of the 11 animals in which pressure flow studies were performed only 2 were obstructed. Of the 7 chronic fibrin glue group 4 animals had urinomas and 2 had unobstructed pressure flow studies. Histological studies and immunohistochemical staining for collagen showed no differences in collagen distribution among the 3 procedures. Laser soldering and fibrin glue pyeloplasties are not superior in the long-term compared to sutured pyeloplasty. Fibrin glue in our animal model had the highest failure rate. Further improvements in the technical aspect of laser tissue welding need to be made to benefit from its theoretical advantages in minimally invasive surgery.
Experimental rotator cuff repair. A preliminary study.
Gerber, C; Schneeberger, A G; Perren, S M; Nyffeler, R W
1999-09-01
The repair of chronic, massive rotator cuff tears is associated with a high rate of failure. Prospective studies comparing different repair techniques are difficult to design and carry out because of the many factors that influence structural and clinical outcomes. The objective of this study was to develop a suitable animal model for evaluation of the efficacy of different repair techniques for massive rotator cuff tears and to use this model to compare a new repair technique, tested in vitro, with the conventional technique. We compared two techniques of rotator cuff repair in vivo using the left shoulders of forty-seven sheep. With the conventional technique, simple stitches were used and both suture ends were passed transosseously and tied over the greater tuberosity of the humerus. With the other technique, the modified Mason-Allen stitch was used and both suture ends were passed transosseously and tied over a cortical-bone-augmentation device. This device consisted of a poly(L/D-lactide) plate that was fifteen millimeters long, ten millimeters wide, and two millimeters thick. Number-3 braided polyester suture material was used in all of the experiments. In pilot studies (without prevention of full weight-bearing), most repairs failed regardless of the technique that was used. The simple stitch always failed by the suture pulling through the tendon or the bone; the suture material did not break or tear. The modified Mason-Allen stitch failed in only two of seventeen shoulders. In ten shoulders, the suture material failed even though the stitches were intact. Thus, we concluded that the modified Mason-Allen stitch is a more secure method of achieving suture purchase in the tendon. In eight of sixteen shoulders, the nonaugmented double transosseous bone-fixation technique failed by the suture pulling through the bone. The cortical-bone-augmentation technique never failed. In definite studies, prevention of full weight-bearing was achieved by fixation of a ten-centimeter-diameter ball under the hoof of the sheep. This led to healing in eight of ten shoulders repaired with the modified Mason-Allen stitch and cortical-bone augmentation. On histological analysis, both the simple-stitch and the modified Mason-Allen technique caused similar degrees of transient localized tissue damage. Mechanical pullout tests of repairs with the new technique showed a failure strength that was approximately 30 percent of that of an intact infraspinatus tendon at six weeks, 52 percent of that of an intact tendon at three months, and 81 percent of that of an intact tendon at six months. The repair technique with a modified Mason-Allen stitch with number-3 braided polyester suture material and cortical-bone augmentation was superior to the conventional repair technique. Use of the modified Mason-Allen stitch and the cortical-bone-augmentation device transferred the weakest point of the repair to the suture material rather than to the bone or the tendon. Failure to protect the rotator cuff post-operatively was associated with an exceedingly high rate of failure, even if optimum repair technique was used. Different techniques for rotator cuff repair substantially influence the rate of failure. A modified Mason-Allen stitch does not cause tendon necrosis, and use of this stitch with cortical-bone augmentation yields a repair that is biologically well tolerated and stronger in vivo than a repair with the conventional technique. Unprotected repairs, however, have an exceedingly high rate of failure even if optimum repair technique is used. Postoperative protection from tension overload, such as with an abduction splint, may be necessary for successful healing of massive rotator cuff tears.
Schmitt, Todd L; Sur, Roger L
2012-03-01
An adult female bottlenose dolphin (Tursiops truncatus) presented with acute anorexia secondary to progressive azotemia (blood urea nitrogen = 213 mg/dl, creatinine [Cr] = 9.5 mg/dl) and electrolyte abnormalities (K = 7.4 mEq/L). It was later diagnosed with postrenal obstruction secondary to bilaterally obstructing ureteral calculi seen on ultrasound. Treatment of the obstruction required two endoscopic procedures, cystoscopy for ureteral stent placement and ureteroscopy to perform intracorporeal lithotripsy on the obstructing calculi. Before the first procedure, the dolphin's azotemia was stabilized with aggressive fluid therapy, peritoneal dialysis, and treatment for acidosis. Diuresis subsequent to the fluid therapy enabled passage of the right obstructing urolith. For both endoscopic procedures, the dolphin was placed in left lateral recumbency due to the peritoneal dialysis catheter in the right retroperitoneal region. For the first procedure, a 12-French (Fr) flexible cystoscope was inserted retrograde into the bladder via the urethra, whereupon a calculus was seen obstructing the left ureteral orifice. A 4.8-Fr, 26-cm double-pigtail ureteral stent was placed up the left ureter to relieve the postrenal obstruction. Inadvertent proximal migration of the left ureteral stent occurred during the procedure. However, renal parameters (serum Cr = 5.8, K = 5.4) improved significantly by the next day. For the second procedure, 28 hr later, ureteroscopy was performed to treat the calculus and replace the existing stent with a longer stent. The left ureteral calculus was pulverized into tiny fragments by using a holmium:yttrium-aluminum-garnet laser inserted through a 6.9-Fr semirigid ureteroscope. The migrated stent was visualized in the distal left ureter and replaced with a 90-cm single-pigtail ureteral stent that was sutured exterior to the urogenital slit and removed 3 days later. Renal function normalized over the next several days, and the dolphin recovered over the next 2 mo.
García Páez, J M; Jorge Herrero, E; Rocha, A; Martín-Maestro, M; Castillo-Olivares, J L; Millán, I; Carrera Sanmartín, A; Cordón, A
2002-10-01
Ostrich pericardium, sutured using a telescoping or overlapping technique, was studied to determine its mechanical behavior. From each of 12 pericardial sacs, four contiguous strips were cut longitudinally, from root to apex, and another four contiguous strips were cut in transverse direction. One of the strips in each set of four was used as an unsutured control and the remaining three were sutured by overlapping 0.5 cm of the tissue and sewing with Gore-tex, Prolene or Pronova. These 96 samples were then subjected to tensile testing along their major axes until rupture. The tensile stresses recorded in the suture materials at the moment tears appeared in the pericardium ranged between 55.99 MPa and 70.23 MPa for Gore-tex in samples cut in the two directions. Shear stress became ostensible at 56 MPa, with clearly evident tears. However, microfracture of the collagen fibers must be produced at much lower stress levels. The comparison of the resistance in kilograms (machine-imposed), without taking into account the sections in which the load was applied, demonstrated only a slight loss of load when the telescoping suture was employed in ostrich pericardium samples. Ostrich pericardium may continue to be an alternative biological material for the construction of heart valve leaflets.
Buchhorn, G. H.; Gilbert, F.; Spahn, G.; Schultz, W.; Klinger, H.-M.
2010-01-01
Aim This experimental study aimed to compare the load-to-failure rate and stiffness of single- versus double-row suture techniques for repairing rotator cuff lesions using two different suture materials. Additionally, the mode of failure of each repair was evaluated. Method In 32 sheep shoulders, a standardized tear of the infraspinatus tendon was created. Then, n = 8 specimen were randomized to four repair methods: (1) Double-row Anchor Ethibond® coupled with polyester sutures, USP No. 2; (2) Double-Row Anchor HiFi® with polyblend polyethylene sutures, USP No. 2; (3) Single-Row Anchor Ethibond® coupled with braided polyester sutures, USP No. 2; and (4) Single-Row Anchor HiFi® with braided polyblend polyethylene sutures, USP No. 2. Arthroscopic Mason–Allen stitches were placed (single-row) and combined with medial horizontal mattress stitches (double-row). All specimens were loaded to failure at a constant displacement rate on a material testing machine. Results Group 4 showed lowest load-to-failure result with 155.7 ± 31.1 N compared to group 1 (293.4 ± 16.1 N) and group 2 (397.7 ± 7.4 N) (P < 0.001). Stiffness was highest in group 2 (162 ± 7.3 N/mm) and lowest in group 4 (84.4 ± 19.9 mm) (P < 0.001). In group 4, the main cause of failure was due to the suture cutting through the tendon (n = 6), a failure case observed in only n = 1 specimen in group 2 (P < 0.001). Conclusions A double-row technique combined with arthroscopic Mason-Allen/horizontal mattress stitches provides high initial failure strength and may minimize the risk of the polyethylene sutures cutting through the tendon in rotator cuff repair when a single load force is used. PMID:20049605
DOE Office of Scientific and Technical Information (OSTI.GOV)
Woodley, Christa M.; Wagner, Katie A.; Bryson, Amanda J.
2012-11-09
The purpose of this report is to assess the performance of bi-directional knotless tissue-closure devices for use in tagging juvenile salmon. This study is part of an ongoing effort at Pacific Northwest National Laboratory (PNNL) to reduce unwanted effects of tags and tagging procedures on the survival and behavior of juvenile salmonids, by assessing and refining suturing techniques, suture materials, and tag burdens. The objective of this study was to compare the performance of the knotless (barbed) suture, using three different suture patterns (treatments: 6-point, Wide “N”, Wide “N” Knot), to the current method of suturing (MonocrylTM monofilament, discontinuous suturesmore » with a 2×2×2×2 knot) used in monitoring and research programs with a novel antiseptic barrier on the wound (“Second Skin”).« less
Can, Ertuğrul; Koçak, Nurullah; Yücel, Özlem Eşki; Gül, Adem; Öztürk, Hilal Eser; Sayın, Osman
2016-01-01
Aim of Study: To describe a simplified ab-interno cow-hitch suture fixation technique for repositioning decentered posterior chamber intraocular lens (PC IOL). Materials and Methods: Two cases are presented with the surgical correction of decentered and subluxated IOL. Ab-interno scleral suture fixation technique with hitch-cow knot in the eye was performed with a ciliary sulcus guide instrument and 1 year follow-up was completed. Results: Both of the patients had well centered lenses postoperatively. Corrected distant and near visual acuities of the patients were improved. There was no significant postoperative complication. In the follow-up period of 1 year, no evidence of suture erosion was found. Conclusions: Ab-interno scleral suture loop fixation with hitch-cow knot in the eye was effective in repositioning decentered or subluxated PC IOLs with excellent postoperative centered lenses and visual outcomes. PMID:27050346
Absorbable Suture as an Apical Matrix in Single Visit Apexification with Mineral Trioxide Aggregate.
Goyal, Ayush; Nikhil, Vineeta; Jha, Padmanabh
2016-01-01
Several procedures have been recommended to induce the root end barrier formation in teeth with open apices. Conventional treatment for such cases will require many appointments with an average duration of 12.9 months. During this period, the root canal is susceptible to reinfection from around the provisional restoration, which may promote apical periodontitis and arrest of apical repair. Mineral trioxide aggregate (MTA) has been successfully used for one visit apexification wherein the root canal can be obturated within 24 hours after placement of MTA. Using a matrix prior to the placement of MTA avoids its extrusion, reduces leakage in the sealing material, and allows favorable response of the periapical tissues. This report presents a case of apexification where an absorbable suture was used as an apical matrix. Use of an absorbable suture circumvents all the problems associated with other conventional materials. Conclusion . Placement of the matrix made from the suture material is predictable and is easily positioned at the apex and the length can be adjusted as required. 10-month follow-up of the case shows resorbed matrix and bone healing in the periapical region. The patient was asymptomatic during the whole follow-up period and tooth exhibited mobility within physiologic limits and was functioning normally.
Armstrong, Lucas C; Chong, Alexander; Livermore, Ryan W; Prohaska, Daniel J; Doyon, Amanda N; Wooley, Paul H
2015-04-01
We conducted a study to evaluate biomechanical performance during destructive testing of several different suture materials in various arthroscopic knot configurations under both in vitro and in situ conditions. Surgeons of different levels of experience tied the knots. Three different arthroscopic knots (static surgeon's, Weston, Tennessee slider) with 3 reverse half-hitches on alternating posts were tested using Fiberwire, ForceFiber, Orthocord, and Ultrabraid suture materials under both in vitro and in situ (blood plasma at 37°C) conditions. Three surgeons of different experience levels tied the knots on a post 30 mm in circumference. A single load-to-failure test was performed. There were no significant in vitro-in situ differences for Ultrabraid in the different knot configurations or with the different experience levels. Surgeon B (intermediate experience) showed no significant differences between test conditions for any knot configuration or suture material. With Tennessee slider knots, surgeon C (least experience) showed significantly lower clinical failure load under both test conditions and had a higher percentage of complete knot slippage. Surgeon B had no knot slippage with use of Fiberwire. Both the aqueous environment and the surgeon's familiarity with certain knots have an effect on knot security.
2011-01-01
Background Colorectal cancer is the second most common tumor in developed countries, with a lifetime prevalence of 5%. About one third of these tumors are located in the rectum. Surgery in terms of low anterior resection with mesorectal excision is the central element in the treatment of rectal cancer being the only option for definite cure. Creating a protective diverting stoma prevents complications like anastomotic failure and meanwhile is the standard procedure. Bowel obstruction is one of the main and the clinically and economically most relevant complication following closure of loop ileostomy. The best surgical technique for closure of loop ileostomy has not been defined yet. Methods/Design A study protocol was developed on the basis of the only randomized controlled mono-center trial to solve clinical equipoise concerning the optimal surgical technique for closure of loop ileostomy after low anterior resection due to rectal cancer. The HASTA trial is a multi-center pragmatic randomized controlled surgical trial with two parallel groups to compare hand-suture versus stapling for closure of loop ileostomy. It will include 334 randomized patients undergoing closure of loop ileostomy after low anterior resection with protective ileostomy due to rectal cancer in approximately 20 centers consisting of German hospitals of all level of health care. The primary endpoint is the rate of bowel obstruction within 30 days after ileostomy closure. In addition, a set of surgical and general variables including quality of life will be analyzed with a follow-up of 12 months. An investigators meeting with a practical session will help to minimize performance bias and enforce protocol adherence. Centers are monitored centrally as well as on-site before and during recruitment phase to assure inclusion, treatment and follow up according to the protocol. Discussion Aim of the HASTA trial is to evaluate the efficacy of hand-suture versus stapling for closure of loop ileostomy in patients with rectal cancer. Trial registration German Clinical Trial Register Number: DRKS00000040 PMID:21303515
Adam, Ahmed; Sookram, Jayveer
2018-01-01
Background To describe a novel bladder fixation technique for use during endoscopic vesicostomy button insertion. Methods After standard cystoscopic visualization of the bladder, a standard 18 G intravenous cannula was inserted into the bladder. A non-absorbable suture thread was placed through this intravenous cannula under cystoscopic vision. The proximal end of the suture was then removed using standard ureteroscopic grasping forceps (3 Fr) through another needle (15 G) inserted next to the initial puncture site (following a path at 30 degrees from the initial puncture tract) into the bladder. The suture ends were brought out of the bladder and tied at the skin level, 2 cm from the intended vesicostomy site. Sutures were removed on the second postoperative day. Results This fixation technique allows for adequate fixation of the bladder dome to the anterior abdominal wall. These sutures also have less potential for cutaneous scarring and pain. No complications were reported. Conclusion This simple fixation technique is easily performed using materials found in every urology suite. It also avoids the skills required with other previously reported fixation suture techniques, and can also be utilized for bladder fixation in cases of vesicoscopic laparoscopic or robotic assisted laparoscopic procedures. PMID:29692696
Chalon, A; Favre, J; Piotrowski, B; Landmann, V; Grandmougin, D; Maureira, J-P; Laheurte, P; Tran, N
2018-06-01
Implantation of a Left Ventricular Assist Device (LVAD) may produce both excessive local tissue stress and resulting strain-induced tissue rupture that are potential iatrogenic factors influencing the success of the surgical attachment of the LVAD into the myocardium. By using a computational simulation compared to mechanical tests, we sought to investigate the characteristics of stress-induced suture material on porcine myocardium. Tensile strength experiments (n = 8) were performed on bulk left myocardium to establish a hyperelastic reduced polynomial constitutive law. Simultaneously, suture strength tests on left myocardium (n = 6) were performed with a standard tensile test setup. Experiments were made on bulk ventricular wall with a single U-suture (polypropylene 3-0) and a PTFE pledget. Then, a Finite Element simulation of a LVAD suture case was performed. Strength versus displacement behavior was compared between mechanical and numerical experiments. Local stress fields in the model were thus analyzed. A strong correlation between the experimental and the numerical responses was observed, validating the relevance of the numerical model. A secure damage limit of 100 kPa on heart tissue was defined from mechanical suture testing and used to describe numerical results. The impact of suture on heart tissue could be accurately determined through new parameters of numerical data (stress diffusion, triaxiality stress). Finally, an ideal spacing between sutures of 2 mm was proposed. Our computational model showed a reliable ability to provide and predict various local tissue stresses created by suture penetration into the myocardium. In addition, this model contributed to providing valuable information useful to design less traumatic sutures for LVAD implantation. Therefore, our computational model is a promising tool to predict and optimize LVAD myocardial suture. Copyright © 2018 Elsevier Ltd. All rights reserved.
Load response and gap formation in a single-row cruciate suture rotator cuff repair.
Huntington, Lachlan; Richardson, Martin; Sobol, Tony; Caldow, Jonathon; Ackland, David C
2017-06-01
Double-row rotator cuff tendon repair techniques may provide superior contact area and strength compared with single-row repairs, but are associated with higher material expenses and prolonged operating time. The purpose of this study was to evaluate gap formation, ultimate tensile strength and stiffness of a single-row cruciate suture rotator cuff repair construct, and to compare these results with those of the Mason-Allen and SutureBridge repair constructs. Infraspinatus tendons from 24 spring lamb shoulders were harvested and allocated to cruciate suture, Mason-Allen and SutureBridge repair groups. Specimens were loaded cyclically between 10 and 62 N for 200 cycles, and gap formation simultaneously measured using a high-speed digital camera. Specimens were then loaded in uniaxial tension to failure, and construct stiffness and repair strength were evaluated. Gap formation in the cruciate suture repair was significantly lower than that of the Mason-Allen repair (mean difference = 0.6 mm, P = 0.009) and no different from that of the SutureBridge repair (P > 0.05). Both the cruciate suture repair (mean difference = 15.7 N/mm, P = 0.002) and SutureBridge repair (mean difference = 15.8 N/mm, P = 0.034) were significantly stiffer than that of the Mason-Allen repair; however, no significant differences in ultimate tensile strength between repair groups were discerned (P > 0.05). The cruciate suture repair construct, which may represent a simple and cost-effective alternative to double-row and double-row equivalent rotator cuff repairs, has comparable biomechanical strength and integrity with that of the SutureBridge repair, and may result in improved construct longevity and tendon healing compared with the Mason-Allen repair. © 2017 Royal Australasian College of Surgeons.
Kiriyama, Yoshimori; Matsumoto, Hideo; Toyama, Yoshiaki; Nagura, Takeo
2014-02-01
The aim of this study was to develop a new suture tension sensor for musculoskeletal soft tissue that shows deformation or movements. The suture tension sensor was 10 mm in size, which was small enough to avoid conflicting with the adjacent sensor. Furthermore, the sensor had good linearity up to a tension of 50 N, which is equivalent to the breaking strength of a size 1 absorbable suture defined by the United States Pharmacopeia. The design and mechanism were analyzed using a finite element model prior to developing the actual sensor. Based on the analysis, adequate material was selected, and the output linearity was confirmed and compared with the simulated result. To evaluate practical application, the incision of the skin and capsule were sutured during simulated total knee arthroplasty. When conventional surgery and minimally invasive surgery were performed, suture tensions were compared. In minimally invasive surgery, the distal portion of the knee was dissected, and the proximal portion of the knee was dissected additionally in conventional surgery. In the skin suturing, the maximum tension was 4.4 N, and this tension was independent of the sensor location. In contrast, the sensor suturing the capsule in the distal portion had a tension of 4.4 N in minimally invasive surgery, while the proximal sensor had a tension of 44 N in conventional surgery. The suture tensions increased nonlinearly and were dependent on the knee flexion angle. Furthermore, the tension changes showed hysteresis. This miniature tension sensor may help establish the optimal suturing method with adequate tension to ensure wound healing and early recovery.
Evaluation of suture material characteristics in an in vitro experimental model.
Justan, I
2010-01-01
The purpose of our study was to indentify the mechanical characteristics of various suture materials. We created an in-vitro experimental flexor tendon model. Materials were divided into four groups: monofilament polypropylene non-absorbable material (group 1); monofilament long-term absorbable material (group 2); polyester multifilament non-absorbable coated material (group 3) and polyester multifilament non-absorbable uncoated material (group 4). We performed 135 tests. The mean maximal tensile strength was 62.92 N in group 1, 75.20 N in group 2, 36.38 N in group 3 and 72.4 N in group 4. Elasticity in millimetres was adjusted at the 35N level: group 1:2.01 mm, group 2:2.18 mm, group 3:2.14 and group 4:1.51 mm. With regard to its elasticity and favourable SD for tensile strength measurements, polyester multifilament non-absorbable uncoated material was considered to be the most suitable material.
Reis, E; Kama, N A; Coskun, T; Korkusuz, P; Ors, U; Aksoy, M; Kulaçoglu, S
1997-01-01
Bacterial translocation induced by intestinal obstruction is suggested to be due to increased intestinal luminal volume, leading to intestinal overgrowth with certain enteric microorganisms and intestinal mucosal damage. If this suggestion is true, maintenance of intestinal mucosal integrity by a cytoprotective agent, a-tocopherol, and inhibition of gastrointestinal secretions by octreotide should decrease the incidence of bacterial translocation and extent of mucosal injury due to intestinal obstruction. Complete intestinal obstruction was created in the distal ileum of male Wistar Albino rats by a single 3-0 silk suture. The animals received subcutaneous injections of 1 ml of physiologic saline (group 1) (PS 24) and 1 ml of saline containing octreotide acetate (100 micrograms/kg) (group 2) (OC 24), at 0, 12 and 24 hours of obstruction. In group 3 (PS 48) and group 4 (OC 48), the rats were treated with subcutaneous physiologic saline (1 ml) and octreotide acetate (100 micrograms/kg), respectively, beginning at the time of obstruction and every 12 hours for 48 hours. The rats in group 5 (Toc 24), were pretreated with intramuscular a-tocopherol 500 mg/kg on day 1 and 8, and underwent laparotomy on day 9. A third dose of a-tocopherol was injected at the time of obstruction on day 9 and no treatment was given thereafter. We tested the incidence of bacterial translocation in systemic organs and circulation and evaluated the histopathological changes in all groups. Treatment with octreotide acetate was found to be ineffective in reducing the incidence of translocation, with no histopathological improvement. Mucosal damage scores, on the other hand, in the a-tocopherol group were statistically less than those in the octreotide and control groups (p < 0.05). Additionally, a-tocopherol treatment decreased the incidence of organ invasion with translocating bacteria, although this difference did not reach statistical significance. Octreotide acetate treatment in complete intestinal obstruction has no effect on the incidence of bacterial translocation. a-Tocopherol, on the other hand, has a cytoprotective effect on intestinal mucosa in intestinal obstruction which, in turn, is thought to decrease bacterial translocation when used in physiological doses and prophylactically.
Péterffy, A; Calabrese, E
1979-01-01
A U.S.-made TA-30 model stapling device was utilized to close the bronchial stump in 146 patients, while conventional manual suturing with chromic catgut was performed for the same purpose in 152 patients. The two groups were comparable in respect of pre-operative status and operative diagnosis. Patients, in whom the stapler was utilized, showed a decreased incidence of bronchial fistula (1% vs. 3%) and empyema without fistula (1% vs. 3%). The stapler, compared with conventional manual sutures, allows a simpler and swifter suture of the bronchial stump, reduces the contamination of the operative field, achieves uniform and tighter closure of the bronchus, leaves a better preserved terminal blood perfusion of the stump and utilizes a more tolerated sewing material with less resultant tissue inflammation.
Karaçam, Zekiye; Ekmen, Hatice; Çalişır, Hüsniye; Şeker, Sibel
2013-01-01
Background: Despite current recommendations against routine use of episiotomy, its incidence is still high in Turkey. The study aimed to identify the prevalence of episiotomy in primiparas, related conditions, and effects of episiotomy on suture materials used, perineal pain, and wound healing 3 weeks postpartum. Materials and Methods: This study was designed as a prospective follow-up study. Data were collected via a questionnaire form between March 2007 and February 2009 in Aydın Government Hospital, Turkey. Three hundred ninety-six primiparas were included in the study by convenience sampling. Results: It was determined that 56.3% of the women had episiotomies. The results of the study revealed that the probability of receiving an episiotomy was decreased in women with lack of legal marriage and unplanned pregnancies, and increased in women who had ineffective pushing efforts approximately four times, miscellaneous two times and baby's head circumference 1.27 times. Moreover, the results of the study demonstrated that an episiotomy increased the number of the suture materials used by approximately five-fold, as well as the prevalence of pain on the first postpartum day. On the third postpartum week evaluation, it was determined that the probability of problems with wound healing and experiencing pain was approximately two times higher among women who received episiotomies than those who did not receive episiotomies. Conclusion: The study revealed that episiotomies in primiparas increased the number of suture materials used and the probability of having perineal pain on the first postpartum day, as well as perineal pain and wound-healing problems during the third postpartum week. PMID:23983762
Chigira, Miho; Akimoto, Masataka
2005-01-01
The adhesion strength of a skin adhesive, octyl-2-cyanoacrylate (Dermabond), was measured under various conditions using porcine skin. The combined use of a skin adhesive and a skin closure tape (n = 5) was significantly stronger than a single application of skin adhesive (n = 5) (p < 0.01). We have tentatively named the wound closure in which a skin adhesive and reinforcement material were combined the Reinforcing Combination Method. To obtain optimum conditions, further studies were done for sequence of application, type of reinforcement material, a number of layers, and width of the suture. The optimum condition for the reinforcement combination was established by applying one layer of skin adhesive over a skin closure tape, over one layer of skin adhesive, with a suture width of 4 cm. This reinforcement combination might be useful in clinical practice.
Karjalainen, T; He, M; Chong, A K S; Lim, A Y T; Ryhanen, J
2010-07-01
Nickel-titanium (NiTi) has been proposed as an alternative material for flexor tendon core suture. To our knowledge, its suitability as a circumferential suture of flexor tendon repair has not been investigated before. The purpose of this ex vivo study was to investigate the biomechanical properties of NiTi circumferential repairs and to compare them with commonly used polypropylene. Forty porcine flexor tendons were cut and repaired by simple running or interlocking mattress technique using 100 microm NiTi wire or 6-0 polypropylene. The NiTi circumferential repairs showed superior stiffness, gap resistance, and load to failure when compared to polypropylene repairs with both techniques. Nickel-titanium wire seems to be a potential material for circumferential repair of flexor tendons. Copyright 2010 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.
Laser-assisted fibrinogen bonding of umbilical vein grafts.
Oz, M C; Williams, M R; Souza, J E; Dardik, H; Treat, M R; Bass, L S; Nowygrod, R
1993-06-01
Despite success with autologous tissue welding, laser welding of synthetic vascular prostheses has not been possible. The graft material appears inert and fails to allow the collagen breakdown and electrostatic bonding that results in tissue welding. To develop a laser welding system for graft material, we repaired glutaraldehyde-tanned human umbilical cord vein graft incisions using laser-assisted fibrinogen bonding (LAFB) technology. Modified umbilical vein graft was incised transversely (1.2 cm). Incisions were repaired using sutures, laser energy alone, or LAFB. For LAFB, indocyanine green dye was mixed with human fibrinogen and the compound applied with forceps onto the weld site prior to exposure to 808 nm diode laser energy (power density 4.8 W/cm 2). Bursting pressures for sutured repairs (126.6 +/- 23.4 mm Hg) were similar to LAFB anastomoses (111.6 +/- 55.0 mm Hg). No evidence of collateral thermal injury to the graft material was noted. In vivo evaluation of umbilical graft bonding with canine arteries demonstrates that LAFB can reliably reinforce sutured anastomoses. The described system for bonding graft material with laser exposed fibrinogen may allow creation or reinforcement of vascular anastomoses in procedures where use of autologous tissue is not feasible.
Flexor Tendon Repair With Looped Suture: 1 Versus 2 Knots.
Gil, Joseph A; Skjong, Christian; Katarincic, Julia A; Got, Christopher
2016-03-01
To assess the strength of flexor tendon repair with looped suture. We hypothesized that, after passing the intact looped suture in the desired repair configuration, splitting the loop and tying 2 independent knots would increase the strength of flexor tendon repair. Thirty-two flexor tendons were harvested and were sharply transected in zone II. The tendons were repaired with a 4-strand core suture repair using 3-0 looped nonabsorbable nylon suture. The harvested tendons were randomly assigned and repaired with either a 1- or a 2-knot construct. The repaired flexor tendons were fixed in a servohydraulic material testing system and were loaded to failure either with uniaxial tension or cyclically. The average force at failure was 43 N for the 1-knot repair and 28 N for the 2-knot repair. The mode of failure of 15 of the flexor tendon repairs that were cyclically loaded to failure was suture pull-out. The average number of cycles and force in cyclic testing that caused failure of flexor tendon repairs was 134 cycles and 31 N for tendons repaired with looped 3-0 suture tied with 1 knot and 94 cycles and 33 N for tendons repaired with looped 3-0 suture tied with 2 knots. Our hypothesis was disproved by the results of this study. This study suggests that, when using looped suture, tying 2 independent knots instead of tying a single knot does not increase the strength of the flexor tendon repair. Copyright © 2016 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.
In vitro evaluation of square and surgeon's knots in large gauge suture.
Gillen, Alex M; Munsterman, Amelia S; Farag, Ramsis; Coleridge, Matthew O D; Hanson, R Reid
2017-02-01
To investigate the strength and size of surgeon's and square knots for starting and ending continuous suture lines using large gauge suture. In vitro mechanical study. Knotted suture. Surgeon's and square knots were tested using 2 and 3 USP polyglactin 910 and 2 USP polydioxanone under linear tension on a universal testing machine. Failure mode and knot holding capacity (KHC) were recorded, and relative knot security (RKS) was calculated as a percentage of KHC. Comparisons were made between number of throws, suture size, suture type, and knot types. Knot volume and weight were assessed by a digital micrometer and balance, respectively. There were no significant differences in KHC (P = .295), RKS (P = .307), volume (P = .128), or weight (P = .310) between square and surgeon's knots at the start or end of suture lines with the same number of throws and suture type. A minimum of 6 throws were required for start knots and 7 throws at end knots to prevent unraveling. Knots tied with 3 polyglactin 910 were strongest (P < .001) and 2 polyglactin 910 produced knots with higher KHC and RKS than 2 polydioxanone (P < .001). No consistent differences were detected between knots types tied with the same suture material; however, number of throws affected KHC and RKS up to 6 throws in start or 7 throws in end knots. The configuration of square and surgeon's knots performed at the end of a continuous line alters their KHC, supporting the use of additional throws for knot security. © 2017 The American College of Veterinary Surgeons.
Suture Embolism of the Left Superior Lobar Pulmonary Artery.
Ahn, Janice Seulgy; Grise, Joy; DelTondo, Joseph A
2018-05-31
Endogenous pulmonary thromboemboli are a common cause of noncardiac sudden natural death. Embolism of exogenous material is a rare but potential finding in autopsies following surgeries, medical procedures, penetrating trauma, and nonparenteral drug abuse. This report describes the first case of a suture embolism of the left superior lobar pulmonary artery following complicated abdominal surgery. © 2018 American Academy of Forensic Sciences.
Naef, Markus; Mouton, Wolfgang G; Wagner, Hans E
2010-12-01
Internal hernias are a specific cause of acute abdominal pain and are a well-known complication after laparoscopic Roux-en-Y gastric bypass for morbid obesity. Although internal hernias are a rare cause of intestinal obstruction, they may evolve towards serious complications, such as extensive bowel ischemia and gangrene, with the need for bowel resection and sometimes for a challenging reconstruction of intestinal continuity. The antecolic position of the Roux limb is associated with a decrease in the incidence of small-bowel obstruction and internal hernias. The best prevention of the formation of these hernias is probably by closure of potential mesenteric defects at the initial operation with a non-absorbable running suture. We present a patient in late pregnancy with a small-bowel volvulus following laparoscopic Roux-en-Y gastric bypass for morbid obesity and discuss the available literature. For a favorable obstetric and neonatal outcome, it is crucial not to delay surgical exploration and an emergency operation usually is mandatory.
Lyu, J; Zhao, P-q
2016-01-01
Purpose We report a simplified ab externo scleral fixation technique to manage the late dislocation of scleral-sutured polymethyl methacrylate (PMMA) intraocular lenses (IOLs) in the absence of capsule support. Materials and methods The technique was performed on five eyes of five patients. Symmetrical scleral pocket tunnels without conjunctival peritomy were created. An anterior vitrectomy via a limbal approach with an anterior chamber infusion or a 3-port pars plana vitrectomy was performed to rescue the dislocated IOL. A long straight suture needle and 23-gauge vitreoretinal forceps were used to conveniently reposition the IOL and loop sutures through the IOL positioning eyelets without externalizing IOL haptics. The outside suture knots were buried under the roof of the scleral tunnels. Results The patients were followed for 5–14 months after surgery. All the operated eyes quickly recovered with negligible corneal endothelial cell loss and mild inflammation. Visual acuity improvement and IOL centration were achieved in all eyes with no major complications. Conclusion The simplified ab externo scleral fixation technique offers an effective and minimally invasive surgical alternative to salvage dislocated previously scleral-sutured PMMA IOLs. PMID:26795420
Lyu, J; Zhao, P-Q
2016-05-01
PurposeWe report a simplified ab externo scleral fixation technique to manage the late dislocation of scleral-sutured polymethyl methacrylate (PMMA) intraocular lenses (IOLs) in the absence of capsule support.Materials and methodsThe technique was performed on five eyes of five patients. Symmetrical scleral pocket tunnels without conjunctival peritomy were created. An anterior vitrectomy via a limbal approach with an anterior chamber infusion or a 3-port pars plana vitrectomy was performed to rescue the dislocated IOL. A long straight suture needle and 23-gauge vitreoretinal forceps were used to conveniently reposition the IOL and loop sutures through the IOL positioning eyelets without externalizing IOL haptics. The outside suture knots were buried under the roof of the scleral tunnels.ResultsThe patients were followed for 5-14 months after surgery. All the operated eyes quickly recovered with negligible corneal endothelial cell loss and mild inflammation. Visual acuity improvement and IOL centration were achieved in all eyes with no major complications.ConclusionThe simplified ab externo scleral fixation technique offers an effective and minimally invasive surgical alternative to salvage dislocated previously scleral-sutured PMMA IOLs.
Fluoride potentiates tubulointerstitial nephropathy caused by unilateral ureteral obstruction.
Kido, Takamasa; Tsunoda, Masashi; Sugaya, Chiemi; Hano, Hiroshi; Yanagisawa, Hiroyuki
2017-12-01
The contamination of ground water by fluoride has been reported worldwide. Most fluoride (approximately 70%) is filtered by the kidneys; humans or experimental animals with renal damage therefore may be more affected by fluoride exposure than those with normal kidney function. Tubulointerstitial fibrosis, which involves macrophage-promoted extracellular matrix production and myofibroblast migration, can be induced in rats by unilateral ureteral obstruction (UUO). We examined the effects of fluoride exposure on tubulointerstitial fibrosis in the obstructed kidney of UUO rats. The left ureters of 6-week-old male rats were ligated using silk sutures. Fluoride was then administered for 2 weeks at doses of 0, 75, and 150ppm in the drinking water. Real-time polymerase chain reaction was performed to analyze transforming growth factor beta 1 (TGF-β 1 ) transcription; histological and immunohistochemical staining were used to identify positive areas within the renal cortex and staining-positive cells by image analysis. Significant increases were observed in the obstructed kidneys of UUO rats exposed to 150ppm fluoride (compared to 0ppm) for areas or number of cells that stained with Masson trichrome or with antibodies against collagen type I, alpha-smooth muscle actin (α-SMA, a myofibroblast marker), ED1, ED2, and ED3 (macrophage markers), and TGF-β 1 . Taken together, these observations suggested that fluoride exacerbates tuburointerstitial nephropathy resulting from UUO, and that this effect occurs via activation of the M2 macrophage-TGF-β1-fibroblast/myofibroblast-collagen synthesis pathway. Copyright © 2017 Elsevier B.V. All rights reserved.
Detecting the limits of bronchial closure methods in an animal model.
Tezel, C; Urek, S; Keles, M; Kiral, H; Koşar, A; Dudu, C; Arman, B
2006-04-01
Bronchopleural fistula is a serious complication of major lung resections that may lead to mortality. An experimental animal model was designed to find out the safest bronchial closure method by comparing leakage rates under pressure. The tracheobronchial trees of 50 freshly dead sheep were prepared for either manual closure or closure with a stapler. After left pneumonectomy, the specimens were divided into five groups (n = 10); 3/0 Premilene suture was used with two "u" sutures + interrupted sutures in Group I; in Group II, 3/0 Premilene sutures with continuous horizontal mattress + over-over continuous sutures were used. In Group III and IV the same techniques were used with 3/0 Vicryl. A stapler was used in Group V. Specimens were intubated with an endotracheal tube, connected to a sphygmomanometer, and subsequently positioned under water. The pressure level at which we detected air bubbles indicated the limits of the technique. The median leakage pressure resistance was significantly lower in Group III (135 mm Hg) ( P = 0.001). The best results were achieved by using the continuous horizontal mattress + over-over continuous suture technique. No statistical significance difference was found between the stapler group, Groups I, II, and IV in terms of median leakage pressures. This trial suggests that manual suture closure using an appropriate technique and monofilament materials is as safe as the stapler.
Does vascular stapling improve compliance of vascular anastomoses?
Stansby, G; Knez, P; Berwanger, C S; Nelson, K; Reichert, V; Schmitz-Rixen, T
2001-01-01
Elastic properties of vessel walls are altered by vascular anastomoses. Such alterations may lead to neointimal hyperplasia, which is a common cause of reocclusion following vascular surgery. The severity of paraanastomotic hypercompliant zones and anastomotic compliance drop depend on suturing material and on elastic properties of the anastomotic vessel segments. This study compares paraanastomotic hypercompliance and anastomotic compliance drop when using a new vascular closure system (VCS) and a conventional, continuous suture line in the preparation of end-to-end anastomoses. Compliance of artery-artery, vein-artery, and polytetrafluoroethylene-artery anastomoses was measured in an artificial circulation system at mean pressures of 60, 90, and 120 mm Hg, comparing conventional suturing and the VCS. When using the VCS for vein-artery anastomoses, significantly less postanastomotic hypercompliance was achieved at mean pressures of 60 mm Hg (14.2 +/-3.8% above remote postanastomotic area), compared to suture (55.1 +/-14.8%, p<0.05). At 90 mm Hg, respective values were 11.0 +/-2.3% for VCS and 54.7 +/-10.1% for suture, p<0.01. At 120 mm Hg, in polytetrafluoroethylene-artery anastomoses, the anastomotic compliance drop was significantly less when using the continuous suture line (93.9 +/-1.1% below remote postanastomotic compliance), compared to VCS (97.2 +/-0.2%, p<0.05). Compared to conventional suturing, use of the VCS reduced postanastomotic hypercompliance in vein-artery anastomoses.
Jaakkola, J J; Oie, L; Nafstad, P; Botten, G; Samuelsen, S O; Magnus, P
1999-01-01
OBJECTIVES: This study assessed the role of polyvinyl chloride (PVC) plastics and textile materials in the home in the development of bronchial obstruction during the first 2 years of life. METHODS: The study was a matched pair case-control study based on a cohort of 3754 newborns in Oslo in 1992 and 1993 who were followed up for 2 years. The case group consisted of 251 children with bronchial obstruction; the control group was matched one-to-one for date of birth. RESULTS: In conditional logistic regression analysis, the risk of bronchial obstruction was related to the presence of PVC flooring (adjusted odds ratio [OR] = 1.89; 95% confidence interval [CI] = 1.14, 3.14) and textile wall materials (adjusted OR = 1.58; 95% CI = 0.98, 2.54). The reference category was wood or parquet flooring and painted walls and ceiling. Further analysis revealed an exposure-response relationship between the assessed amount of PVC and other plasticizer-containing surface materials and the risk of bronchial obstruction. CONCLUSIONS: This study provides new evidence of the role of PVC and textile wall materials in the development of bronchial obstruction in young children. PMID:9949747
Jaakkola, J J; Oie, L; Nafstad, P; Botten, G; Samuelsen, S O; Magnus, P
1999-02-01
This study assessed the role of polyvinyl chloride (PVC) plastics and textile materials in the home in the development of bronchial obstruction during the first 2 years of life. The study was a matched pair case-control study based on a cohort of 3754 newborns in Oslo in 1992 and 1993 who were followed up for 2 years. The case group consisted of 251 children with bronchial obstruction; the control group was matched one-to-one for date of birth. In conditional logistic regression analysis, the risk of bronchial obstruction was related to the presence of PVC flooring (adjusted odds ratio [OR] = 1.89; 95% confidence interval [CI] = 1.14, 3.14) and textile wall materials (adjusted OR = 1.58; 95% CI = 0.98, 2.54). The reference category was wood or parquet flooring and painted walls and ceiling. Further analysis revealed an exposure-response relationship between the assessed amount of PVC and other plasticizer-containing surface materials and the risk of bronchial obstruction. This study provides new evidence of the role of PVC and textile wall materials in the development of bronchial obstruction in young children.
Bueno, Letícia Rossi; Binda, Marcia; Monego, Heleusa; Scherer, Roberta Luísa; Rolim, Karen Machado; Bottini, Alessandra Leal; Fregnani, José H T G; dos Reis, Ricardo
2015-06-01
Compare blood loss during cold knife conization of the cervix with and without lateral hemostatic sutures in the cervical branches of the uterine arteries. Randomized clinical trial. Hospital de Clínicas de Porto Alegre (HCPA). 102 patients that underwent cold knife conization. Women that underwent cold knife conization of the cervix were randomized to undergo the procedure with or without lateral hemostatic sutures. blood loss measured in grams. operative time and postoperative intervention. Only the participants were blinded to group assignment. From March 2009 to August 2012, patients were randomly assigned to one of the study groups. There were no differences in amount of blood loss between patients that underwent the procedure with and without sutures (p = 0.39). Operative time was shorter in the group without suture (p = 0.020). There were no differences in intervention due to bleeding (p = 0.20). Blood loss was greater among menstruating women than for menopausal women (p = 0.011). There were no differences in amount of blood lost between smoking and nonsmoking patients (p = 0.082). Lateral hemostatic sutures do not affect the amount of intraoperative bleeding or the number of postoperative interventions. Their use is not necessary because they result in longer operative time, have a higher cost due to the use of suture material and pose the risk of ureter lesion in case the sutures are not placed at a lower position in the cervix. ClinicalTrials. gov identifier: NCT02184975. Copyright © 2015 IJS Publishing Group Limited. Published by Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Lin, Erica; Li, Yaning; Ortiz, Christine; Boyce, Mary C.
2014-12-01
Geometrically structured interfaces in nature possess enhanced, and often surprising, mechanical properties, and provide inspiration for materials design. This paper investigates the mechanics of deformation and failure mechanisms of suture interface designs through analytical models and experiments on 3D printed polymer physical prototypes. Suture waveforms with generalized trapezoidal geometries (trapezoidal, rectangular, anti-trapezoidal, and triangular) are studied and characterized by several important geometric parameters: the presence or absence of a bonded tip region, the tip angle, and the geometry. It is shown that a wide range (in some cases as great as an order of magnitude) in stiffness, strength, and toughness is achievable dependent on tip bonding, tip angle, and geometry. Suture interfaces with a bonded tip region exhibit a higher initial stiffness due to the greater load bearing by the skeletal teeth, a double peak in the stress-strain curve corresponding to the failure of the bonded tip and the failure of the slanted interface region or tooth, respectively, and an additional failure and toughening mechanism due to the failure of the bonded tip. Anti-trapezoidal geometries promote the greatest amplification of properties for suture interfaces with a bonded tip due the large tip interface area. The tip angle and geometry govern the stress distributions in the teeth and the ratio of normal to shear stresses in the interfacial layers, which together determine the failure mechanism of the interface and/or the teeth. Rectangular suture interfaces fail by simple shearing of the interfaces. Trapezoidal and triangular suture interfaces fail by a combination of shear and tensile normal stresses in the interface, leading to plastic deformation, cavitation events, and subsequent stretching of interface ligaments with mostly elastic deformation in the teeth. Anti-trapezoidal suture interfaces with small tip angles have high stress concentrations in the teeth and fail catastrophically by tooth failure, whereas larger tip angles exhibit a shear failure of the interfaces. Therefore, larger tip angles and trapezoidal or triangular geometries promote graceful failure, and smaller tip angles and anti-trapezoidal geometries promote more brittle-like failure. This dependence is reminiscent of biological systems, which exhibit a range of failure behaviors with limited materials and varied geometry. Triangular geometries uniquely exhibit uniform stress distributions in its teeth and promote the greatest amplification of mechanical properties. In both the bonded and unbonded cases, the predictions from the presented analytical models and experimental results on 3D printed prototypes show excellent agreement. This validates the analytical models and allows for the models to be used as a tool for the design of new materials and interfaces with tailored mechanical behavior.
Albumen Glue, New Material for Conjunctival Graft Surgery, an Animal Experiment
NASA Astrophysics Data System (ADS)
Kartiwa, A.; Miraprahesti, R.; Sovani, I.; Enus, S.; Boediono, A.
2017-02-01
Attach conjunctival graft commonly used are suture technique and fibrin glue. This study was to investigate albumen glue as an alternative to suture technique in attaching conjunctival graft in rabbits. Aim of this study was to compare the conjunctival wound healing between albumen glue and suture technique in rabbit eye as a model. There was an experimental animal study included 32 eyes (16 rabbits) in PT. Bio Farma (Persero) and Histology Laboratory, Faculty of Medicine, Padjadjaran University from March 2014 to July 2104. The study consisted of albumen glue group and suture technique group. The examination included the comparison of conjunctival graft attachment and histologic examination by microscopically was done to obtain the wound gap, then analyze by Mann-Whitney test. The results indicated that the graft attachment was significantly better-using albumen glue (grade 4) compared to suture (grade 2-3) on day-1 after surgery (p=0,000). The wound gap was smaller using albumen glue (0-0,33 μm versus 5,33-14 μm ; p=0,0005) on 10 minutes after surgery and 0 μm versus 0,33-4 μm ; p=0,0005 on day-7 after surgery. In conclusion, the graft attachment using albumen glue was better and the wound gap was smaller using albumen glue than suture technique.
Tendon cell outgrowth rates and morphology associated with kevlar-49.
Zimmerman, M; Gordon, K E
1988-12-01
A rat tendon cell model was used to evaluate the in vitro biocompatibility of kevlar-49. The cell response to kevlar was compared to carbon AS-4 and nylon sutures. Three trials were run and cell growth rates were statistically similar for all the materials tested. A separate experiment was conducted in which the same fiber materials were placed in the same Petri dish. Again, the rates were similar for each material. Finally, the cells were observed with a scanning electron microscope, and the three classic cell morphologies associated with this tendon cell model were observed. Also, cellular attachment to the fiber and cellular encapsulation of the fiber were identical for the three materials tested. Kevlar-49 proved to be comparable to carbon AS4 and nylon sutures in terms of cellular response and cell outgrowth rates.
Zwagerman, Nathan T; Geltzeiler, Mathew N; Wang, Eric W; Fernandez-Miranda, Juan C; Snyderman, Carl H; Gardner, Paul A
2018-05-30
We present a case of cerebrospinal fluid (CSF) leak after endoscopic endonasal resection of a large clival chordoma in an obese patient. The leak was at the lower reconstruction at the craniocervical junction and had failed repositioning. Using the V-Loc™ wound closure device (Covidien, New Haven, Connecticut) to suture the nasoseptal flap to the nasopharyngeal fascia, a water-tight seal was created and, along with a lumbar drain, the patient healed successfully.CSF leak after an endoscopic endonasal approach (EEA) to intradural pathologies remains one of the more common complications.1-4 Various closure techniques have been developed5-8 with success in mitigating this risk, but all have their limitations and rely on multiple layers including vascularized flaps like the nasoseptal flap.9-11 Endonasal suturing of graft materials offers the advantage of creating a water-tight seal. We present the use of the V-Loc™ wound closure device (Covidien) to successfully seal a postoperative CSF leak. The absorbable V-Loc™ wound closure device does not require the surgeon to tie knots, which is the most challenging step in a deep, 2-dimensional corridor. The suture is barbed and is anchored by threading the needle through a prefabricated loop at the end of the suture which locks in place. Each throw of the suture through tissue maintains the suture line as the barbs catch the tissue and prevent retraction. After successful closure, the needle can simply be cut off.The V-Loc™ wound closure device (Covidien) is a safe and effective adjunct to reconstruction after endoscopic endonasal skull base surgery as it provides an option for graft/flap suturing.A written release from the patient whose name or likeness is submitted as part of this Work is on file.
Güleçyüz, Mehmet F; Mazur, Alexandra; Schröder, Christian; Braun, Christian; Ficklscherer, Andreas; Roßbach, Björn P; Müller, Peter E; Pietschmann, Matthias F
2015-06-01
The purpose of this study was to analyze the biomechanical integrity of suture anchors of different materials (titanium, PEEK [polyether ether ketone], poly-L-lactic acid [PLLA], and β-tricalcium phosphate PLLA) and almost identical design for rotator cuff repair in human humeri positioned in a water bath at room and body temperature undergoing cyclic loading rather than single-pull or static tests. Four different anchor models (n = 6) were tested using healthy human cadaveric humeri in a water bath thermostatically regulated at 20°C and 37°C. A cyclic testing protocol was used. The maximum failure load, the system displacement, and the respective mode of failure were recorded. There were no significant differences regarding the maximum failure load values between the 20°C groups and 37°C groups for the 4 different anchor materials. The displacement values for the 20°C groups and 37°C groups also were not statistically significant. Anchor and suture dislocations were the predominant modes of failure; suture ruptures were observed in few cases. This study shows that there are no significantly relevant differences regarding the maximum failure loads and the displacement values of the tested suture anchor systems in a wet environment at 20°C or 37°C. The temperature differences do not seem to affect the modes of failure either. Titanium, PEEK, PLLA, and β-tricalcium phosphate PLLA suture anchors for rotator cuff repair can be expected-on the basis of this investigation comparing laboratory temperature with body temperature and a wet environment-to perform in vivo similar to in vitro testing. Copyright © 2015 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Shirazi, Mehdi; Ariafar, Ali; Babaei, Amir Hossein; Ashrafzadeh, Abdosamad; Adib, Ali
2016-11-01
Urethrocutaneous fistula (UCF) is the most prevalent complication after hypospadias repair surgery. Many methods have been developed for UCF correction, and the best technique for UCF repair is determined based on the size, location, and number of fistulas, as well as the status of the surrounding skin. In this study, we introduced and evaluated a simple method for UCF correction after tubularized incised plate (TIP) repair. This clinical study was conducted on children with UCFs ≤ 4 mm that developed after TIP surgery for hypospadias repair. The skin was incised around the fistula and the tract was released from the surrounding tissues and the dartos fascia, then ligated with 5 - 0 polydioxanone (PDS) sutures. The dartos fascia, as the second layer, was covered on the fistula tract with PDS thread (gauge 5 - 0) by the continuous suture method. The skin was closed with 6 - 0 Vicryl sutures. After six months of follow-up, surgical outcomes were evaluated based on fistula relapse and other complications. After six months, relapse occurred in only one patient, a six-year-old boy with a single 4-mm distal opening, who had undergone no previous fistula repairs. Therefore, in 97.5% of the cases, relapse was non-existent. Other complications, such as urethral stenosis, intraurethral obstruction, and epidermal inclusion cysts, were not seen in the other patients during the six-month follow-up period. This repair method, which is simple, rapid, and easily learned, is highly applicable, with a high success rate for the closure of UCFs measuring up to 4 mm in any location.
2017-01-01
Background Uniportal video-assisted thoracoscopic surgery (VATS) is an alternative modality for treatment of primary spontaneous pneumothorax (PSP) with its less invasiveness and acceptable surgical outcomes. However, a few reports have been introduced for wound management to achieve better cosmetic wound healing and for placement of the chest tube in uniportal VATS. Thus, we aimed to evaluate the feasibility of our novel method for wound closure and concomitant tube placement using continuous barbed suture material in uniportal VATS for PSP. Methods Between July 2012 and December 2015, consecutive 31 patients (22 males) underwent uniportal VATS to treat PSP. Bilateral approaches were performed in four patients, thus total 35 cases were enrolled. We divided them into two groups with one group of 17 (48.5%) cases (group A), using barbed absorbable wound closure device for knotless continuous wound closure and subsequent chest tube anchoring, and the other group of 18 (51.4%) cases (group B), using conventional suture anchoring after skin closure using absorbable suture device. Postoperative surgical outcomes were compared to assess the feasibility of this technique. Results Demographic data demonstrate no significant difference in both groups. There was no significant difference in length of hospital stay (3.7±1.2 vs. 4.1±1.2 days, P=0.267) and in median chest tube indwelling time (2.4±0.9 vs. 3.1±1.2 days, P=0.066), respectively. Operation time in group A was shorter than in group B but there was no significant difference (41.7±11.8 vs. 45.6±16.0 minutes, P=0.415). There was neither conversion to two or three port VATS in all cases. In group A, all chest tubes were removed with concomitant sealing the tube removal site by pulling the thread. Residual knots do not exist that stitch out procedure is not required. There was no wound complication in both groups during the median follow-up period of 18 months. Conclusions Knotless, barbed suture material technique for continuous wound closure with concomitant chest tube placement achieved equivocal outcomes in comparison to the conventional suture anchoring method. We suggest this simple technique for wound closure and easy tube removal with cosmetic wound healing in uniportal VATS for PSP. PMID:28616277
Graefe, H; Wollenberg, B; Brocks, C
2008-09-01
In this work cyanoacrylate-based skin adhesives used in Germany for skin closure in head and neck surgery are compared with respect to ease of application, cost-effectiveness and cosmetic results. We compared 25 wounds sealed with a skin adhesive with 25 suture-sealed wounds. Bonding of surgical wounds with glue had a high level of acceptance in all patients. The tedious, time-consuming and sometimes painful postoperative removal of many sutures in patients is omitted. Patients can shower soon afterwards without additional protection as the adhesive provides a waterproof barrier. Problems of wound healing can immediately be detected through the transparent skin adhesive. Cosmetic long-term results of skin closure by adhesives are comparable to suture-sealed wounds. The adhesives available on the market differ mainly in the form of the applicator, the viscosity on application, as well as the strength after hardening. The application is easy to implement and significantly faster than conventional suturing. Apart from the cost savings of materials compared to the use of skin sutures and investment of Steri-Strips, expensive anesthesia and surgical time can also be saved.
The structure and effect of suture zones in the Larsen C Ice Shelf, Antarctica
NASA Astrophysics Data System (ADS)
McGrath, Daniel; Steffen, Konrad; Holland, Paul R.; Scambos, Ted; Rajaram, Harihar; Abdalati, Waleed; Rignot, Eric
2014-03-01
Ice shelf fractures frequently terminate where they encounter suture zones, regions of material heterogeneity that form between meteoric inflows in ice shelves. This heterogeneity can consist of marine ice, meteoric ice with modified rheological properties, or the presence of fractures. Here, we use radar observations on the Larsen C Ice Shelf, Antarctica, to investigate (i) the termination of a 25 km long rift in the Churchill Peninsula suture zone, which was found to contain 60 m of accreted marine ice, and (ii) the along-flow evolution of a suture zone originating at Cole Peninsula. We determine a steady state field of basal melting/freezing rates and apply it to a flowline model to delineate the along-flow evolution of layers within the ice shelf. The thickening surface wedge of locally accumulated meteoric ice, which likely has limited lateral variation in its mechanical properties, accounts for 60% of the total ice thickness near the calving front. Thus, we infer that the lower 40% of the ice column and the material heterogeneities present there are responsible for resisting fracture propagation and thereby delaying tabular calving events, as demonstrated in the >40 year time series leading up to the 2004/2005 calving event for Larsen C. This likely represents a highly sensitive aspect of ice shelf stability, as changes in the oceanic forcing may lead to the loss of this heterogeneity.
FARIA, Raquel Lourdes; CARDOSO, Lincoln Marcelo Lourenço; AKISUE, Gokithi; PEREIRA, Cristiane Aparecida; JUNQUEIRA, Juliana Campos; JORGE, Antonio Olavo Cardoso; SANTOS JÚNIOR, Paulo Villela
2011-01-01
Objective The objective of this study was to compare the antimicrobial effect of mouthwashes containing Calendula officinalis L., Camellia sinensis (L.) Kuntze and 0.12% chlorhexidine digluconate on the adherence of microorganisms to suture materials after extraction of unerupted third molars. Material and Methods Eighteen patients with unerupted maxillary third molars indicated for extraction were selected (n=6 per mouthwash). First, the patients were subjected to extraction of the left tooth and instructed not to use any type of antiseptic solution at the site of surgery (control group). After 15 days, the right tooth was extracted and the patients were instructed to use the Calendula officinalis, Camellia sinensis or chlorhexidine mouthwash during 1 week (experimental group). For each surgery, the sutures were removed on postoperative day 7 and placed in sterile phosphate-buffered saline. Next, serial dilutions were prepared and seeded onto different culture media for the growth of the following microorganisms: blood agar for total microorganism growth; Mitis Salivarius bacitracin sucrose agar for mutans group streptococci; mannitol agar for Staphylococcus spp.; MacConkey agar for enterobacteria and Pseudomonas spp., and Sabouraud dextrose agar containing chloramphenicol for Candida spp. The plates were incubated during 24-48 h at 37ºC for microorganism count (CFU/mL). Results The three mouthwashes tested reduced the number of microorganisms adhered to the sutures compared to the control group. However, significant differences between the control and experimental groups were only observed for the mouthwash containing 0.12% chlorhexidine digluconate. Conclusions Calendula officinalis L. and Camellia sinensis (L.) Kuntze presented antimicrobial activity against the adherence of microorganisms to sutures but were not as efficient as chlorhexidine digluconate. PMID:21986652
Effect of topical epigallocatechin gallate on corneal neovascularization in rabbits.
Koh, Chang Hyun; Lee, Hyun Soo; Chung, Sung Kun
2014-05-01
The aim of this study was to evaluate the efficacy of topical application of epigallocatechin gallate (EGCG) for the treatment of corneal neovascularization in a rabbit model. Corneal neovascularization was induced in 12 rabbits by placing a black silk suture in the corneal stroma (24 eyes) for a week. After suturing, 1 randomly chosen eye of the 12 rabbits was treated with topical EGCG at 2 different concentrations: 0.01% (group 1) and 0.1% (group 2), whereas the contralateral eyes were treated with sterilized balanced salt solution as the control. All eye drops were applied for 2 weeks after suturing. The suture materials were removed from all eyes on day 7. The surface area of corneal neovascularization was measured and analyzed in all eyes on days 7 and 14. On day 14, all eyes were extracted to measure the concentrations of vascular endothelial growth factor (VEGF) messenger RNA and cyclooxygenase-2 (COX-2) protein. The surface area of induced corneal neovascularization was significantly smaller only in group 2 compared with that of the control group on days 7 and 14 (P < 0.001). The change in surface area of corneal neovascularization after removal of the suture material was not significantly different between all 3 groups. VEGF messenger RNA levels were significantly lower in group 2 than in the control group (P < 0.001). The concentration of COX-2 was significantly lower in group 2 than in the control group (P = 0.043), but no significant difference was observed between group 1 and the control group. Topical administration of EGCG effectively inhibits corneal neovascularization in rabbits. This inhibitory effect is probably related to the suppression of VEGF and COX-2 meditated angiogenesis.
Cruz, José Vinicius; Regadas, Francisco Sergio P; Murad-Regadas, Sthela Maria; Rodrigues, Lusmar Veras; Benicio, Fernando; Leal, Rogério; Carvalho, César G; Fernandes, Margarete; Roche, Lucimar M C; Miranda, Antônio Carlos; Câmara, Lucia; Pereira, Joaquim Costa; Parra, Antonio Mallén; Leal, Vilmar Moura
2011-01-01
Since anorectocele is usually associated with mucosa prolapse and/or rectal intussusceptions, it was developed a stapled surgical technique using one circular stapler. To report the results of Transanal Repair of Rectocele and Rectal Mucosectomy with one Circular Stapler (TRREMS procedure) in the treatment of anorectocele with mucosa prolapse in a prospective multicenter trial. It was conducted by 14 surgeons and included 75 female patients, mean aged 49.6 years, with symptoms of obstructed defecation due to grade 2 (26.7%) and grade 3 (73.3%) anorectocele associated with mucosa prolapse and/or rectal intussusception (52.0%) and an average validated Wexner constipation score of 16. All patients were evaluated by a proctological examination, cinedefecography, anal manometry and colonic transit time. The TRREMS procedure consists of the manual removal of the rectocele wall with circumferential rectal mucosectomy performed with a circular stapler. The mean follow-up time was 21 months. All patients presented obstructed defecation and they persisted with symptoms despite conservative treatment. The mean operative time was 42 minutes. In 13 (17.3%) patients, bleeding from the stapled line required hemostatic suture. Stapling was incomplete in 2 (2.6%). Forty-nine patients (65.3%) required 1 hospitalization day, the remainder (34.7%) 2 days. Postoperatively, 3 (4.0%) patients complained of persistent rectal pain and 7 (9.3%) developed stricture on the stapled suture subsequently treated by stricturectomy under anesthesia (n = 1), endoscopic stricturectomy with hot biopsy forceps (n = 3) and digital dilatation (n = 3). Postoperative cinedefecography showed residual grade I anorectoceles in 8 (10.6%). The mean Wexner constipation score decreased significantly from 16 to 4 (0-4: n = 68) (6: n = 6) (7: n = 1) (P<0.0001). Current trial results suggest that TRREMS procedure is a safe and effective technique for the treatment of anorectocele associated with mucosa prolapse. The stapling technique is low-cost as requires the use of a single circular stapler.
Hinse, Stéphanie; Ménard, Jérémie; Rouleau, Dominique M; Canet, Fanny; Beauchamp, Marc
2016-11-01
Important rotator cuff repair failure rates have prompted this study of the techniques and materials used in order to optimize clinical results. Is the reconstruction of the rotator cuff biomechanically stronger when using: 1) transosseous with 2 mm braided tape suture (TOT), 2) transosseous with multi-strand No. 2 sutures (TOS), or 3) double row suture bridge with suture anchors loaded with No. 2 braided sutures (DRSB)? Twenty-four cadaveric pig shoulders were randomized in the three repair constructs. The infraspinatus muscle was detached to mimic a complete laceration, repaired with one of the three repair groups and tested with a traction machine. Cameras recorded tendon displacement during trials. The ultimate strength (US), failure mode, and tendon displacement, qualified by the bare footprint area (BFA), during cycling phases were compared. The US for DRSB was 175 ± 82 Newton (N), 91 ± 51 N for TOS, and 147 ± 63 N for TOT. The BFA after 200 cycles was 81 ± 34% for TOS, 57 ± 41% for TOT, and 26 ± 27% for DRSB repairs. No significant difference was observed between the DRSB and TOT results for US or BFA percentage of loss during all the cycling phases. TOS proved to be weaker than TOT and DRSB. All the ruptures occurred in the tendon, which seems to be the weakness of rotator cuff repairs. The use of braided tape suture with a transosseous technique seems to be a cost effective, equivalent alternative implant compared to anchor fixation. Copyright © 2016 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.
Estimating incision healing rate for surgically implanted acoustic transmitters from recaptured fish
Schoonyan, Abby; Kraus, Richard T.; Faust, Matthew D.; Vandergoot, Christopher; Cooke, Steven J.; Cook, H. Andrew; Hayden, Todd A.; Krueger, Charles C.
2017-01-01
Background Intracoelomic implantation of electronic tags has become a common method in fishery research, but rarely are fish examined by scientists after release to understand the extent that surgical incisions have healed. Walleye (Sander vitreus) are a valuable, highly exploited fishery resource in the Laurentian Great Lakes. Here, fishery capture of walleye with internal acoustic transmitters combined with a high reward program provided multiple opportunities to examine photographs and quantify the status of surgical incisions. Walleye (n = 926) from reef and river spawning populations in Lake Erie and Lake Huron were implanted with acoustic transmitters during spring spawning events from 2011 to 2016. Incisions were closed with polydioxanone monofilament using two to three interrupted sutures. Out of 276 recaptured fish, 60 incision sites were clearly visible in photographs, and these were scored by two independent readers for incision closure, inflammation, and the presence of sutures.Results While incision sites were completely closed by 61 days post-release (95% CI 44–94), sutures remained for up to 866 days. Sutures were expelled serially during a protracted period, and the probability of observing at least one suture in a recaptured fish declined below 50% after 673 days (95% CI 442–1016). Inflammation at the incision increased during the first 71 days and then declined monotonically, remaining detectable at low levels.Conclusion Our results emphasized that sutures remained in free-ranging fish past the time when they were beneficial for incision healing. Most dissolvable sutures have been designed for use in endotherms where the body temperature and internal milieu differ dramatically from the conditions experienced by fishes in temperate climates. Identification of new suture materials for fish that facilitate healing while absorbing or dissolving in a reasonable period (e.g., a few weeks to three months) in colder temperatures (e.g., <12 °C) would be beneficial to mitigate potential adverse impacts from inflammation at the incision.
Feucht, Matthias J; Grande, Eduardo; Brunhuber, Johannes; Burgkart, Rainer; Imhoff, Andreas B; Braun, Sepp
2013-12-01
A tear of the posterior medial meniscus root (PMMR) is increasingly recognized as a serious knee joint injury. Several suture techniques for arthroscopic transtibial pull-out repair have been described; however, only limited data about the biomechanical properties of these techniques are currently available. There are significant differences between the tested suture techniques, with more complex suture configurations providing superior biomechanical properties. Controlled laboratory study. A total of 40 porcine medial menisci were randomly assigned to 1 of 4 groups (10 specimens each) according to suture technique: two simple stitches (TSS), horizontal mattress suture (HMS), modified Mason-Allen suture (MMA), and two modified loop stitches (TLS). Meniscus-suture constructs were subjected to cyclic loading followed by load-to-failure testing in a servohydraulic material testing machine. During cyclic loading, the HMS and TLS groups showed a significantly higher displacement after 100, 500, and 1000 cycles compared with the TSS and MMA groups. After 1000 cycles, the highest displacement was found for the TLS group, with significant differences compared with all other groups. During load-to-failure testing, the highest maximum load and yield load were observed for the MMA group, with statistically significant differences compared with the TSS and TLS groups. With regard to stiffness, the TSS and MMA groups showed significantly higher values compared with the HMS and TLS groups. The MMA technique provided the best biomechanical properties with regard to cyclic loading and load-to-failure testing. The TSS technique seems to be a valuable alternative. Both the HMS and TLS techniques have the disadvantage of lower stiffness and higher displacement during cyclic loading. Using a MMA technique may improve healing rates and avoid progressive extrusion of the medial meniscus after transtibial pull-out repair of PMMR tears. The TSS technique may be used as an alternative that is easier to perform, but a more careful rehabilitation program is possibly necessary to avoid early failure.
[Plastic surgery to correct deformities of the ear].
Naumann, A
2005-08-18
For the plastic-surgical correction of mild deformities of the ears, well-proven incisional and suturing techniques are available. Only in exceptional cases is skin grafting or the use of cartilage ersatz material required. In the plastic surgical treatment of moderate to severe ear deformities, in contrast, not only incisional and suturing techniques, but also free skin grafts and ersatz materials are needed. At the ENT Department of the Ludwig-Maximilian University in Munich, plastic reconstruction of moderate to severe deformities of the external ear using porous polyethylene implants instead of rib cartilage grafts has been practiced with success for the past two years or so. Porous polyethylene implants provide good results and may help to avoid pre- and postoperative morbidity at donor site defects.
Fugazzi, Russell W; Fransson, Boel A; Curran, Katie M; Davis, Howard M; Gay, John M
2013-02-01
To (1) evaluate biomechanical strength of 4 different laparoscopic knots using 2 suture types, and (2) evaluate carotid artery ligature bursting pressure of 2 knots using a single suture type. Biomechanical materials testing. Suture material (3-0 polydioxanone, 3-0 polyglactin 910). Four knot types were tested: 4S-modified Roeder (4SMR) Weston plus 3 square throws (W3S); Weston plus 3 granny throws (W3G); and a 4 square throw knot as a control (control); 24 specimens of each knot type were tied with 3-0 polyglactin 910 and 24 of 3 knot types (4SMR, W3S, control) were tied with 3-0 polydioxanone. Suture loop constructs were tested to 3 mm displacement failure and ultimate failure. Carotid artery ligation bursting pressure was tested using 10 samples each of 4SMR and W3S knots with 3-0 polyglactin 910. The W3S, W3G, and controls were similar. The 4SMR was similar to W3S using 3-0 PDS but the 4SMR had lower load to failure and greater elongation than the Weston using 3-0 polyglactin 910. The 4SMR had a higher slippage rate with 3-0 polyglactin 910. All ligatures withstood supraphysiologic pressures. Surgeons using 3-0 polyglactin 910 should consider using the Weston knot with added throws during laparoscopic procedures. © Copyright 2012 by The American College of Veterinary Surgeons.
Stanley, W.D.
1989-01-01
Large-scale geoelectrical anomalies have been mapped with geomagnetic depth sounding (GDS) and magnetotelluric (MT) surveys in the Carpathian Mountains region. These anomalies are associated with the zone of closure between stable Europe and a complex of microplates in front of the converging African plate. The zone of closure, or suture zone, is largely occupied by an extensive deformed flysch belt. The models derived to fit the observed geoelectrical data are useful in the study of other suture zones, and Carpathian structures have been compared with areas currently being studied in the western Cordillera of the U.S.A. Models derived for a smaller-scale suture zone mapped in western Washington State have features that are similar to the Carpathian models. The geoelectrical models for both the Carpathian and Washington anomalies require dipping conductive slabs of 1-5 ?? m material that extends to depths > 20 km. In both instances there is evidence that these materials may merge with lower crustal-mantle conductors along the down-dip margins of the slab. The main conductive units are interpreted to be sedimentary rocks that have been partially subducted due to collisional processes. Heat flow is low in both regions and it is difficult to explain fully the deep conduction mechanisms; however, evidence suggests that the conduction at depth may include electronic conduction in sulfide mineral or carbon films as well as ionic conduction in fluids or partial melt. ?? 1989.
Ji, Jong-Hun; Shafi, Mohamed; Moon, Chang-Yun; Park, Sang-Eun; Kim, Yeon-Jun; Kim, Sung-Eun
2013-11-01
Arthroscopic removal, now the main treatment option, has almost replaced open surgery for treatment of resistant calcific tendinitis. In some cases of chronic calcific tendinitis of the shoulder, the calcific materials are hard and adherent to the tendon. Removal of these materials can cause significant intratendinous tears between the superficial and deep layers of the degenerated rotator cuff. Thus far, there are no established surgical techniques for removing the calcific materials while ensuring cuff integrity. Good clinical results for rotator cuff repair were achieved by using an arthroscopic suture bridge technique in patients with long-standing calcific tendinitis. Intact rotator cuff integrity and recovery of signal change on follow-up magnetic resonance imaging scans were confirmed. This is a technical note about a surgical technique and its clinical results with a review of relevant published reports. © 2013 Chinese Orthopaedic Association and Wiley Publishing Asia Pty Ltd.
Pauly, Stephan; Kieser, Bettina; Schill, Alexander; Gerhardt, Christian; Scheibel, Markus
2010-10-01
Biomechanical comparison of different suture-bridge configurations of the medial row with respect to initial construct stability (time 0, porcine model). In 40 porcine fresh-frozen shoulders, the infraspinatus tendons were dissected from their insertions. All specimens were operated on by use of the suture-bridge technique, only differing in terms of the medial-row suture-grasping configuration, and randomized into 4 groups: (1) single-mattress (SM) technique, (2) double-mattress (DM) technique, (3) cross-stitch (CS) technique, and (4) double-pulley (DP) technique. Identical suture anchors were used for all specimens (medial: Bio-Corkscrew FT 5.5 [Arthrex, Naples, FL]; lateral: Bio-PushLock 3.5 [Arthrex]). All repairs were cyclically loaded from 10 to 60 N until 10 to 200 N (20-N stepwise increase after 50 cycles each) with a material testing machine. Forces at 3 and 5 mm of gap formation, mode of failure, and maximum load to failure were recorded. The DM technique had the highest ultimate tensile strength (368.6 ± 99.5 N) compared with the DP (248.4 ± 122.7 N), SM (204.3 ± 90 N), and CS (184.9 ± 63.8 N) techniques (P = .004). The DM technique provided maximal force resistance until 3 and 5 mm of gap formation (90.0 ± 18.1 N and 128.0 ± 32.3 N, respectively) compared with the CS (72 ± 8.9 N and 108 ± 20.2 N, respectively), SM (66.0 ± 8.9 N and 90.0 ± 26.9 N, respectively), and DP (62.2 ± 6.2 N and 71 ± 13.2 N, respectively) techniques (P < .05 for each 3 and 5 mm of gap formation). The main failure mode was suture cutting through the tendon. Comparing the 4 different suture-bridge techniques, we found that modified application of suture-bridge repair with double medial mattress stitches significantly enhanced biomechanical construct stability at time 0 in this porcine ex vivo model. This technique increases initial stability and resistance to suture cutting through the rotator cuff tendon after arthroscopic suture-bridge repair. Copyright © 2010 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Biomechanical Comparison of Parallel and Crossed Suture Repair for Longitudinal Meniscus Tears.
Milchteim, Charles; Branch, Eric A; Maughon, Ty; Hughey, Jay; Anz, Adam W
2016-04-01
Longitudinal meniscus tears are commonly encountered in clinical practice. Meniscus repair devices have been previously tested and presented; however, prior studies have not evaluated repair construct designs head to head. This study compared a new-generation meniscus repair device, SpeedCinch, with a similar established device, Fast-Fix 360, and a parallel repair construct to a crossed construct. Both devices utilize self-adjusting No. 2-0 ultra-high molecular weight polyethylene (UHMWPE) and 2 polyether ether ketone (PEEK) anchors. Crossed suture repair constructs have higher failure loads and stiffness compared with simple parallel constructs. The newer repair device would exhibit similar performance to an established device. Controlled laboratory study. Sutures were placed in an open fashion into the body and posterior horn regions of the medial and lateral menisci in 16 cadaveric knees. Evaluation of 2 repair devices and 2 repair constructs created 4 groups: 2 parallel vertical sutures created with the Fast-Fix 360 (2PFF), 2 crossed vertical sutures created with the Fast-Fix 360 (2XFF), 2 parallel vertical sutures created with the SpeedCinch (2PSC), and 2 crossed vertical sutures created with the SpeedCinch (2XSC). After open placement of the repair construct, each meniscus was explanted and tested to failure on a uniaxial material testing machine. All data were checked for normality of distribution, and 1-way analysis of variance by ranks was chosen to evaluate for statistical significance of maximum failure load and stiffness between groups. Statistical significance was defined as P < .05. The mean maximum failure loads ± 95% CI (range) were 89.6 ± 16.3 N (125.7-47.8 N) (2PFF), 72.1 ± 11.7 N (103.4-47.6 N) (2XFF), 71.9 ± 15.5 N (109.4-41.3 N) (2PSC), and 79.5 ± 25.4 N (119.1-30.9 N) (2XSC). Interconstruct comparison revealed no statistical difference between all 4 constructs regarding maximum failure loads (P = .49). Stiffness values were also similar, with no statistical difference on comparison (P = .28). Both devices in the current study had similar failure load and stiffness when 2 vertical or 2 crossed sutures were tested in cadaveric human menisci. Simple parallel vertical sutures perform similarly to crossed suture patterns at the time of implantation.
Gogoi, Dolly; Choudhury, Arup Jyoti; Chutia, Joyanti; Pal, Arup Ratan; Khan, Mojibur; Choudhury, Manash; Pathak, Pallabi; Das, Gouranga; Patil, Dinkar S
2014-04-01
Surface modification of silk fibroin (SF) materials using environmentally friendly and non-hazardous process to tailor them for specific application as biomaterials has drawn a great deal of interest in the field of biomedical research. To further explore this area of research, in this report, polypropylene (PP) grafted muga (Antheraea assama) SF (PP-AASF) suture is developed using plasma treatment and plasma graft polymerization process. For this purpose, AASF is first sterilized in argon (Ar) plasma treatment followed by grafting PP onto its surface. AASF is a non-mulberry variety having superior qualities to mulberry SF and is still unexplored in the context of suture biomaterial. AASF, Ar plasma treated AASF (AASFAr) and PP-AASF are subjected to various characterization techniques for better comparison and the results are attempted to correlate with their observed properties. Excellent mechanical strength, hydrophobicity, antibacterial behavior, and remarkable wound healing activity of PP-AASF over AASF and AASFAr make it a promising candidate for application as sterilized suture biomaterial. Copyright © 2013 Wiley Periodicals, Inc.
Injectable suture device for intraocular lens fixation.
Smith, Jesse M; Erlanger, Michael; Olson, Jeffrey L
2015-12-01
We describe a surgical technique for scleral fixation of a posterior chamber intraocular lens (PC IOL) using a 24-gauge injectable polypropylene suture delivery system. A 3-piece PC IOL is inserted into the anterior chamber of the eye. Two sclerotomies are made 1.5 mm posterior to the limbus using a microvitreoretinal blade. The 24-gauge injector delivers a preformed suture loop into the eye with the double-armed needles still external to the eye. Each polypropylene IOL haptic is directed through the loop using microforceps. The suture loop is tightened around the haptic, and the attached needles are used to fixate the IOL to the sclera and close the sclerotomies simultaneously. This technique has been used in an ex vivo porcine eye and in an aphakic patient. In the latter, the IOL was quickly fixated to the sclera and maintained a stable position postoperatively. Dr. Olson has a patent pending for the device described in this article. No other author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Trans-septal suturing following septoplasty: an alternative for nasal packing.
Ghimire, A; Limbu, T R; Bhandari, R
2012-09-01
Septoplasty is one of the most common otorhinolaryngologic surgical procedure. It is customary to place a pack in the nose as a part of nasal surgery to stop bleeding, enhance apposition of mucosal flaps, and stabilize the operated septal cartilage and bones. But nasal packing is not an innocuous procedure. The most common problem encountered by the patients after septoplasty with nasal pack is the pain and discomfort in post operative period. The study has been performed to compare the complications and outcome of septoplasty with or without nasal packing. Forty four patients were randomly allocated into two groups, Group A (n = 21) and Group B (n = 23). In Group A trans-septal suture and in Group B intranasal pack was used following septoplasty. Both groups were compared for postoperative pain, postoperative complications and surgical outcome. Among 44 patients 31 patients were male and 13 patients were female. Most of the patients ie 79.5% were operated for nasal obstruction. Only one patient had postoperative nasal bleeding requiring nasal pack in Group A. Higher Postoperative pain score, longer hospital stay and more complications were observed in Group B patients. No difference was found in patients' satisfaction after the operation. Septoplasty can be safely performed without postoperative nasal packing and is preferred to avoid postoperative pain, discomfort and other complications.
Direct percutaneous jejunostomy--an underutilized interventional technique?
Sparrow, Patrick; David, Elizabeth; Pugash, Robyn
2008-01-01
Our aim in this study was to report our single-center experience with direct percutaneous jejunostomy over a 4-year period with regard to technical success rate, immediate and late complications, and patient tolerance of the procedure. Institutional records of 22 consecutive patients who underwent radiological insertion of a percutaneous jejunostomy for a variety of indications were reviewed. The proximal jejunum was punctured under either fluoroscopic or ultrasonic guidance, and following placement of retention sutures, a 10- to 12-Fr catheter inserted. There was a 100% technical success rate in placement involving a total of seven operators. The indications for placement were prior gastric resection, newly diagnosed resectable esophageal or gastric carcinoma, unresectable gastric carcinoma with outlet obstruction, and palliative drainage of bowel obstruction. Mean duration of follow-up was 100 days, and catheter placement 57.7 days. There were six minor early complications, consisting of loss of two retention anchors requiring repuncture, three cases of localized excessive postprocedural pain, and one failed relief of symptoms of small bowel obstruction. Four tubes developed late complications (two blocked, one catheter cracked, and one inadvertently pulled out). Three of the four were successfully replaced through the existing tracts. One patient subsequently developed a minor skin infection, while another developed late pericatheter leakage from ascites. We conclude that direct percutaneous jejunostomy is a valuable treatment modality applicable to a number of clinical scenarios, with a high technical success rate and low serious complication rate.
The Effect of Capsulotomy and Capsular Repair on Hip Distraction: A Cadaveric Investigation.
Khair, M Michael; Grzybowski, Jeffrey S; Kuhns, Benjamin D; Wuerz, Thomas H; Shewman, Elizabeth; Nho, Shane J
2017-03-01
To quantify how increasing interportal capsulotomy size affects the force required to distract the hip and to biomechanically compare simple side-to-side suture repair to acetabular-based suture anchors as capsular repair techniques. Twelve fresh-frozen cadaveric hip specimens were dissected to the capsuloligamentous complex of the hip joint and fixed in a material testing system, such that a pure axial distraction of the iliofemoral ligament could be achieved. After each hip in was tested an intact state, sequential distraction was tested with 2, 4, 6, and 8 cm capsulotomies. Specimens were assigned randomly to be repaired with either 4 side-to-side suture repair (n = 6) or 2 double-loaded all-suture anchors (n = 6). The distraction force as well as the relative distraction force percentage normalized to the intact capsule were compared between suture repair and suture anchor repair groups. Increasing the size of the capsulotomy resulted in less force required to distract the hip to 6 mm. The force decreased as the capsulotomy was extended with statistical significance in distraction force seen between the intact state and the 4 cm (P = .003), 6 cm (P < .001), and 8 cm (P ≤ .001) capsulotomy but not for the intact state compared to the 2 cm capsulotomy (P = .28). Statistical significance in relative distraction force was seen for each of the capsulotomy conditions (P < .001 for all conditions compared with the intact state). The side-to-side suture repair construct (104.3% of intact force) required greater force to distraction to 6 mm compared with the suture anchor repair (87.1% of intact force) (P = .008). An interportal capsulotomy significantly affected the force required to distract the hip in a cadaveric model, with the larger the size of capsulotomy resulting in less force required to distract the hip. When we performed an interportal capsulotomy, the iliofemoral ligament strength was altered significantly but capsular repair with either side-to-side sutures or suture anchor-based repair was able to restore the capsular strength to a native intact hip. We found, however, that the side-to-side suture repair was better able to restore the distraction force compared with suture anchor repair. Capsular management during hip arthroscopy remains a debated topic, with multiple techniques involving both capsulotomy and capsular closure published in the literature. This study provides insight into capsular stability against axial stress under capsulotomy and capsular repair conditions. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Bilateral syndactyly. A unique case with surgical correction.
Cisco, R W; Pitts, T E; Cicchinelli, L D; Caldarella, D J
1993-11-01
Cases must be treated on an individual basis, appreciating the complexity of the syndactyly, considering the patient compliance, and understanding the goals of the surgical correction. Extensive discussion with the patient and parents must occur to clarify the goals of the surgery, the expectations, and possible complications. Careful preoperative planning and incision design is paramount in obtaining satisfactory results. Skin grafting may be required, either full-thickness from a variety of donor sites or split-thickness grafting as in one case study reported. Adjunctively, manipulation and stretching of the web space for 2 to 3 months preoperatively may be helpful to achieve more laxity of the soft tissues. The choice of suture material is of particular concern when dealing with a small child. It is usually wise to use an absorbable suture material for skin closure in a small child to prevent undue emotional stress to the child or even further anesthesia upon suture removal. Vascular compromise caused by soft tissue tension in not an infrequent occurrence. As with any surgery that addresses largely cosmetic deformities, there is no substitute for exact prior planning, meticulous technique, and surgeon experience to optimize results.
An Endovascular Approach to the Entrapped Central Venous Catheter After Cardiac Surgery
DOE Office of Scientific and Technical Information (OSTI.GOV)
Desai, Shamit S., E-mail: shamit.desai@northwestern.edu; Konanur, Meghana; Foltz, Gretchen
PurposeEntrapment of central venous catheters (CVC) at the superior vena cava (SVC) cardiopulmonary bypass cannulation site by closing purse-string sutures is a rare complication of cardiac surgery. Historically, resternotomy has been required for suture release. An endovascular catheter release approach was developed.Materials and MethodsFour cases of CVC tethering against the SVC wall and associated resistance to removal, suggestive of entrapment, were encountered. In each case, catheter removal was achieved using a reverse catheter fluoroscopically guided over the suture fixation point between catheter and SVC wall, followed by the placement of a guidewire through the catheter. The guidewire was snared andmore » externalized to create a through-and-through access with the apex of the loop around the suture. A snare placed from the femoral venous access provided concurrent downward traction on the distal CVC during suture release maneuvers.ResultsIn the initial attempt, gentle traction freed the CVC, which fractured and was removed in two sections. In the subsequent three cases, traction alone did not release the CVC. Therefore, a cutting balloon was introduced over the guidewire and inflated. Gentle back-and-forth motion of the cutting balloon atherotomes successfully incised the suture in all three attempts. No significant postprocedural complications were encountered. During all cases, a cardiovascular surgeon was present in the interventional suite and prepared for emergent resternotomy, if necessary.ConclusionAn endovascular algorithm to the “entrapped CVC” is proposed, which likely reduces risks posed by resternotomy to cardiac surgery patients in the post-operative period.« less
Adam, Frank; Pape, Dietrich; Schiel, Karin; Steimer, Oliver; Kohn, Dieter; Rupp, Stefan
2004-01-01
Reliable fixation of the soft hamstring grafts in ACL reconstruction has been reported as problematic. The biomechanical properties of patellar tendon (PT) grafts fixed with biodegradable screws (PTBS) are superior compared to quadrupled hamstring grafts fixed with BioScrew (HBS) or Suture-Disc fixation (HSD). Controlled laboratory study with roentgen stereometric analysis (RSA). Ten porcine specimens were prepared for each group. In the PT group, the bone plugs were fixed with a 7 x 25 mm BioScrew. In the hamstring group, four-stranded tendon grafts were anchored within a tibial tunnel of 8 mm diameter either with a 7 x 25 mm BioScrew or eight polyester sutures knotted over a Suture-Disc. The grafts were loaded stepwise, and micromotion of the graft inside the tibial tunnel was measured with RSA. Hamstring grafts failed at lower loads (HBS: 536 N, HSD 445 N) than the PTBS grafts (658 N). Stiffness in the PTBS group was much greater compared to the hamstring groups (3500 N/mm versus HBS = 517 N/mm and HSD = 111 N/mm). Irreversible graft motion after graft loading with 200 N was measured at 0.03 mm (PTBS), 0.38mm (HBS), and 1.85mm (HSD). Elasticity for the HSD fixation was measured at 0.67 mm at 100 N and 1.32 mm at 200 N load. Hamstring graft fixation with BioScrew and Suture-Disc displayed less stiffness and early graft motion compared to PTBS fixation. Screw fixation of tendon grafts is superior to Suture-Disc fixation with linkage material since it offers greater stiffness and less graft motion inside the tibial tunnel. Our results revealed graft motion for hamstring fixation with screw or linkage material at loads that occur during rehabilitation. This, in turn, may lead to graft laxity.
Ghafoor, Bakhtawar; Ansari, Umar; Bhatti, Muhammad Faraz; Akhtar, Hafsah; Darakhshan, Fatima
2016-01-01
The study focuses on the development of novel Aloe vera based polymeric composite films and antimicrobial suture coatings. Polyvinyl alcohol (PVA), a synthetic biocompatible and biodegradable polymer, was combined with Aloe vera, a natural herb used for soothing burning effects and cosmetic purposes. The properties of these two materials were combined together to get additional benefits such as wound healing and prevention of surgical site infections. PVA and Aloe vera were mixed in a fixed quantity to produce polymer based films. The films were screened for antibacterial and antifungal activity against bacterial (E. coli, P. aeruginosa) and fungal strains (Aspergillus flavus and Aspergillus tubingensis) screened. Aloe vera based PVA films showed antimicrobial activity against all the strains; the lowest Aloe vera concentration (5%) showed the highest activity against all the strains. In vitro degradation and release profile of these films was also evaluated. The coating for sutures was prepared, in vitro antibacterial tests of these coated sutures were carried out, and later on in vivo studies of these coated sutures were also performed. The results showed that sutures coated with Aloe vera/PVA coating solution have antibacterial effects and thus have the potential to be used in the prevention of surgical site infections and Aloe vera/PVA based films have the potential to be used for wound healing purposes. PMID:27965710
Cesana, Giovanni; Cioffi, Stefano; Giorgi, Riccardo; Villa, Roberta; Uccelli, Matteo; Ciccarese, Francesca; Castello, Giorgio; Scotto, Bruno; Olmi, Stefano
2018-03-01
The purpose of this paper was to search for predictive factors for proximal leakage after laparoscopic sleeve gastrectomy (LSG) in a large cohort from a single referral center. One thousand seven hundred and thirty-eight patients, collected in a prospectively held database from 2008 to 2016, were retrospectively analyzed. The correlation between postoperative leakage and both preoperative (age, gender, height, weight, BMI, and obesity-related morbidities) and operative variables (the distance from pylorus at which the gastric section was started, operative time, experience of surgeons who performed the LSG, and the surgical materials used) was analyzed. The experience of the surgeons was calculated in the number of LSGs performed. The surgical materials considered were stapler, cartridges, and reinforcement of the suture. Proximal leakage was observed in 45 patients out of 1738 (2.6%). No correlation was found between leakage and the preoperative variables analyzed. The operative variables that were found to be associated with lower incidence of leakage at the multivariate analysis (p < 0.05) were the reinforcement of the staple line (or overriding suture or buttressing materials) and the experience of the surgeons. A distance of less than 2 cm from the pylorus resulted to be significantly related to a higher incidence of fistula at the univariate analysis. In this large consecutive cohort study of LSG, proximal staple line reinforcement (buttress material or suture) reduced the risk of a leak. The risk of a proximal leak was much higher in the surgeons first 100 cases, which has implications for training and supervision during this "learning curve" period.
A training phantom for ultrasound-guided needle insertion and suturing.
Nattagh, Khashayar; Siauw, Timmy; Pouliot, Jean; Hsu, I-Chow; Cunha, J Adam
2014-01-01
During gynecologic brachytherapy (BT), suturing and image-guided needle insertions are highly skill-dependent tasks. Medical residents often have to practice these techniques in the operating room; this is sub-optimal for many reasons. We present a fast and low-cost method of building realistic and disposable gynecologic phantoms, which can be used to train physicians new to gynecologic BT. Phantoms comprised a rectal cavity large enough to accommodate a standard transrectal ultrasound (US) probe, a vaginal cavity, a uterus, a uterine canal, and a cervix, all embedded in a gelatin matrix. The uterus was made of gelatin and coated with rubber to mimic the texture of soft tissue and for computed tomography (CT) and US image contrast. The phantom's durability, longevity, construction times, materials costs, CT, and US image quality were recorded. The speed of sound in the gelatin was measured using pulse echo measurements. Anatomic structures were distinguishable using CT and US. For the first phantom, material costs were under $200, curing time was approximately 48 hours, and active participation time was 3 hours. Reusable parts allowed for reduction in time and cost for subsequent phantoms: under $20, 24 hours curing time, and 1 hour active participation time. The speed of sound in the gelatin ranged from 1495 to 1506 m/s. A method for constructing gelatin gynecologic phantoms was developed. It can be used for training in image-guided BT needle insertion, placing a suture on the vaginal wall, and suturing the cervical lip. Copyright © 2014 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.
Porro, Laura B; Holliday, Casey M; Anapol, Fred; Ontiveros, Lupita C; Ontiveros, Lolita T; Ross, Callum F
2011-08-01
The mechanical behavior of mammalian mandibles is well-studied, but a comprehensive biomechanical analysis (incorporating detailed muscle architecture, accurate material properties, and three-dimensional mechanical behavior) of an extant archosaur mandible has never been carried out. This makes it unclear how closely models of extant and extinct archosaur mandibles reflect reality and prevents comparisons of structure-function relationships in mammalian and archosaur mandibles. We tested hypotheses regarding the mechanical behavior of the mandible of Alligator mississippiensis by analyzing reaction forces and bending, shear, and torsional stress regimes in six models of varying complexity. Models included free body analysis using basic lever arm mechanics, 2D and 3D beam models, and three high-resolution finite element models of the Alligator mandible, incorporating, respectively, isotropic bone without sutures, anisotropic bone with sutures, and anisotropic bone with sutures and contact between the mandible and the pterygoid flange. Compared with the beam models, the Alligator finite element models exhibited less spatial variability in dorsoventral bending and sagittal shear stress, as well as lower peak values for these stresses, suggesting that Alligator mandibular morphology is in part designed to reduce these stresses during biting. However, the Alligator models exhibited greater variability in the distribution of mediolateral and torsional stresses than the beam models. Incorporating anisotropic bone material properties and sutures into the model reduced dorsoventral and torsional stresses within the mandible, but led to elevated mediolateral stresses. These mediolateral stresses were mitigated by the addition of a pterygoid-mandibular contact, suggesting important contributions from, and trade-offs between, material properties and external constraints in Alligator mandible design. Our results suggest that beam modeling does not accurately represent the mechanical behavior of the Alligator mandible, including important performance metrics such as magnitude and orientation of reaction forces, and mediolateral bending and torsional stress distributions. J.Morphol. 2011. © 2011 Wiley-Liss, Inc. Copyright © 2011 Wiley-Liss, Inc.
Park, Maxwell C; Peterson, Alexander; Patton, John; McGarry, Michelle H; Park, Chong J; Lee, Thay Q
2014-03-01
Rotator cuff repair involving fewer tendon suture passes without compromising biomechanical performance would represent a technical advancement. An inter-implant "medial pulley-mattress" transosseous-equivalent (MP-TOE) repair requiring fewer tendon suture-passes was hypothesized to provide equivalent biomechanical characteristics compared to the control. In 6 human cadaveric shoulders, a transosseous-equivalent (TOE) repair (control) was performed utilizing 2 separate medial mattresses resulting in 4 tendon-bridging sutures. In 6 matched-pairs, 2 single-loaded anchors were used to create a medial inter-implant mattress construct (all sutures shuttled in 1 tendon pass per anchor)-after knot-tying, the same tendon-bridging pattern as the control was created. A materials testing machine cyclically loaded each repair from 10-180 N for 30 cycles; each repair subsequently underwent failure testing. Gap and strain were measured with a video digitizing system. A "technical efficiency ratio" (TER) was defined as: (#knots + #suture passes + #suture limbs)/#fixation points. Cyclic and failure testing demonstrated no significant differences between constructs. Gap formation at cycle 30 was 5.3 ± 0.8 mm (TOE) and 5.0 ± 0.3 mm (MP-TOE) (P = .62). Cycle 30 anterior strain values were -16.0 ± 7.3% (TOE) and -15.8 ± 6.6% (MP-TOE) (P = .99). Yield loads were 208.7 ± 2.7 N (TOE) and 204.0 ± 1.3 N (MP-TOE) (P = .17). Mode of failure demonstrated less tendon cut-out with the MP-TOE repair. The MP-TOE repair has a TER of 2.0 vs 2.5 for the control. The MP-TOE repair requiring fewer tendon suture passes, yet creating an additional inter-implant mattress configuration, is biomechanically equivalent to the original TOE technique, and may limit failure with improved medial load-sharing capacity. A TER may help quantify technical ease and help standardize comparisons between repair techniques. Copyright © 2014 Journal of Shoulder and Elbow Surgery Board of Trustees. All rights reserved.
The biomechanical role of the chondrocranium and sutures in a lizard cranium.
Jones, Marc E H; Gröning, Flora; Dutel, Hugo; Sharp, Alana; Fagan, Michael J; Evans, Susan E
2017-12-01
The role of soft tissues in skull biomechanics remains poorly understood. Not least, the chondrocranium, the portion of the braincase which persists as cartilage with varying degrees of mineralization. It also remains commonplace to overlook the biomechanical role of sutures despite evidence that they alter strain distribution. Here, we examine the role of both the sutures and the chondrocranium in the South American tegu lizard Salvator merianae We use multi-body dynamics analysis (MDA) to provide realistic loading conditions for anterior and posterior unilateral biting and a detailed finite element model to examine strain magnitude and distribution. We find that strains within the chondrocranium are greatest during anterior biting and are primarily tensile; also that strain within the cranium is not greatly reduced by the presence of the chondrocranium unless it is given the same material properties as bone. This result contradicts previous suggestions that the anterior portion (the nasal septum) acts as a supporting structure. Inclusion of sutures to the cranium model not only increases overall strain magnitudes but also leads to a more complex distribution of tension and compression rather than that of a beam under sagittal bending. © 2017 The Authors.
[Suture simulator - Cleft palate surgery].
Devinck, F; Riot, S; Qassemyar, A; Belkhou, A; Wolber, A; Martinot Duquennoy, V; Guerreschi, P
2017-04-01
Cleft palate requires surgery in the first years of life, furthermore repairing anatomically the soft and hard palate is complex on a surgical level because of the fine tissues and the local intraoral configuration. It is valuable to train first on simulators before going to the operating room. However, there is no material dedicated to learning how to perform intraoral sutures in cleft palate surgery. We made one, in an artisanal manner, in order to practice before the real surgical gesture. The simulator was designed based on precise anatomical data. A steel pipe, fixed on a rigid base represented the oral cavity. An adapted split spoon represented the palate. All pieces could be removed in order to apply a hydrocellular dressing before training for sutures. Our simulator was tested by 3 senior surgeons in our department in close to real-life conditions in order to evaluate its anatomical accuracy. It is valuable to have a simulator to train on cleft palate sutures within teaching university hospitals that manage this pathology. Our simulator has a very low cost, it is easy to make and is anatomically accurate. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
The biomechanical role of the chondrocranium and sutures in a lizard cranium
Gröning, Flora; Dutel, Hugo; Fagan, Michael J.; Evans, Susan E.
2017-01-01
The role of soft tissues in skull biomechanics remains poorly understood. Not least, the chondrocranium, the portion of the braincase which persists as cartilage with varying degrees of mineralization. It also remains commonplace to overlook the biomechanical role of sutures despite evidence that they alter strain distribution. Here, we examine the role of both the sutures and the chondrocranium in the South American tegu lizard Salvator merianae. We use multi-body dynamics analysis (MDA) to provide realistic loading conditions for anterior and posterior unilateral biting and a detailed finite element model to examine strain magnitude and distribution. We find that strains within the chondrocranium are greatest during anterior biting and are primarily tensile; also that strain within the cranium is not greatly reduced by the presence of the chondrocranium unless it is given the same material properties as bone. This result contradicts previous suggestions that the anterior portion (the nasal septum) acts as a supporting structure. Inclusion of sutures to the cranium model not only increases overall strain magnitudes but also leads to a more complex distribution of tension and compression rather than that of a beam under sagittal bending. PMID:29263126
Seo, Su Hyun; Kim, Min Chan; Choi, Hong Jo; Jung, Ghap Joong
2012-01-01
Purpose Mechanical stapler is regarded as a good alternative to the hand sewing technique, when used in gastric reconstruction. The circular stapling method has been widely applied to gastrectomy (open orlaparoscopic), for gastric cancer. We illustrated and compared the hand-sutured method to the circular stapling method, for Billroth-II, in patients who underwent laparoscopy assisted distal gastrectomy for gastric cancer. Materials and Methods Between April 2009 and May 2011, 60 patients who underwent laparoscopy assisted distal gastrectomy, with Billroth-II, were enrolled. Hand-sutured Billroth-II was performed in 40 patients (manual group) and circular stapler Billroth-II was performed in 20 patients (stapler group). Clinicopathological features and post-operative outcomes were evaluated and compared between the two groups. Results Nosignificant differences were observed in clinicopathologic parameters and post-operative outcomes, except in the operation times. Operation times and anastomosis times were significantly shorter in the stapler group (P=0.004 and P<0.001). Conclusions Compared to the hand-sutured method, the circular stapling method can be applied safely and more efficiently, when performing Billroth-II anastomosis, after laparoscopy assisted distal gastrectomy in patients with gastric cancer. PMID:22792525
Ramoglu, Sabri Ilhan; Sonmez, Mehmet Fatih
2016-01-01
Summary Background/objective: The aim of this study was to investigate the effects of different concentrations of ozone (O3) therapy on bone regeneration in response to an expansion of the inter-premaxillary suture in rats. Materials and methods: Forty-eight Wistar rats were randomly divided into four groups (n = 12). In groups I, II, and III, 1ml of O3 at 10, 25, and 40 µg/ml was injected at the premaxillary suture, respectively. In group IV (control group), 1ml of saline solution was injected at the same point during the expansion procedure for 5 days. Bone regeneration in the suture was evaluated histomorphometrically. The area of new bone and fibrotic area, the number of osteoblasts and osteoclasts, and the amount of vascularity were measured and compared. The density of the newly formed bone in the expansion area was measured by using cone beam computed tomography. Data were analyzed using the Kruskal–Wallis one-way analysis of variance and post hoc Student-Newman–Keuls tests. Results: New bone area, fibrotic area, osteoblast and osteoclast numbers, and the amount of vascularity were significantly higher in experimental groups compared with the control group (P < 0.001). The density of newly formed bone (P < 0.001), new bone formation (P = 0.009), number of capillaries (P < 0.001), number of osteoclasts (P = 0.016), and number of osteoblasts (P < 0.001) in the maxillary sutures were highest in the 25 μg/ml O3 group compared with the other experimental groups and control group. Conclusions/implications: The application of O3 therapy can stimulate bone regeneration in an orthopedically expanded inter-premaxillary suture during both the expansion and retention periods. PMID:26136437
[Dorsal capsular imbrication for dorsal instability of the distal radioulnar joint].
Unglaub, F; Manz, S; Bruckner, T; Leclère, F M; Hahn, P; Wolf, M B
2013-12-01
To stabilize the distal radioulnar joint (DRUJ) by performing dorsal capsular imbrication in patients presenting with dorsal instability. The goal was to reduce pain and prevent the occurrence of posttraumatic arthrosis. Posttraumatic dorsal instability of the DRUJ with missing block while performing translational activities in the DRUJ or subluxation while actively rotating the forearm. Cases, in which other stabilizing techniques, such as, sutures of the triangular fibrocartilage complex failed. DRUJ arthrosis, previous surgical interventions to the capsule area of the DRUJ, instabilities due to osseous reasons (malposition or pseudarthrosis) should already have been treated. Dorsal approach and opening of the 5th extensor compartment to expose the dorsal joint capsule. A longitudinal division of the capsule was performed and sufficient tissue on the radial and ulnar border was retained to ensure a solid suture technique. Then 2 U-shaped sutures using FiberWire suture material were made. Correction of the malposition and repositioning the forearm into supination. Tightening of the prepared capsule sutures and closing of the retinaculum with a resorbable suture. Patients wore a long-arm cast with the forearm being in supination for a period of 4 weeks. Following cast removal, patients wore a forearm splint for a period of 4 weeks to limit forearm pronation/supination at 45°. Full load on the wrist was allowed after 12 weeks. The subjective and functional outcomes of 20 patients having received capsular imbrication using this technique were good and entailed no significant complications. The postoperative DASH was 15.8 points. Of the 20 patients, 17 patients (85%) had a reduction of pain. Symptoms of DRUJ instability could be reduced in 18 patients (90%). Pronation/supination of the wrist was not restricted postoperatively.
An ad hoc 3D-printed tool facilitates intraesophageal suturing in experimental surgery
Steinemann, D.C.; Müller, P.C.; Apitz, M.; Nickel, F.; Kenngott, H.G.; Müller-Stich, B.P.; Linke, G.R.
2018-01-01
Background Three-dimensional printing (3DP) has become popular for development of anatomic models, preoperative planning, and production of tailored implants. A novel laparoscopic, transgastric procedure for distal esophageal mucosectomy was developed. During this procedure a space holder had to be introduced into the distal esophagus for exposure during suturing. The production process and evaluation of a 3DP space holder are described herein. Material and methods Computer-aided design software was used to develop models printed from polylactic acid. The prototype was adapted after testing in a cadaveric model. Subsequently the device was evaluated in a non-survival porcine model. A mucosal purse-string suture was placed as orally as possible in the esophagus, in the intervention group with and in the control group without use of the tool (n=8 each). The distance of the stitches from the Z-line was measured. The variability of stitches indicated the suture quality. Results The median maximum distance from Z-line to purse-string suture was larger in the intervention group (5.0 [3.3-6.4] versus 2.4 [2.0-4.1] cm;P=0.013). The time taken to place the sutures was shorter in the control group (P<0.001). Stitch variance tended to be greater in the intervention group (2.3 [0.9-2.5] versus 0.7 [0.2-0.4] cm;P=0.051). The time required for design and production of a tailored tool was below 24 h. Conclusions 3DP in experimental surgery enables rapid production, permits repeated adaptation until a tailored tool is obtained, and ensures independence from industrial partners. With the aid of the space holder more orally located esophageal lesions came within reach. PMID:29433890
Comparing the tensile strength of square and reversing half-hitch alternating post knots
Wu, Vincent; Sykes, Edward A.; Mercer, Dale; Hopman, Wilma M.; Tang, Ephraim
2017-01-01
Background Square knots are the gold standard in hand-tie wound closure, but are difficult to reproduce in deep cavities, inadvertently resulting in slipknots. The reversing half-hitch alternating post (RHAP) knot has been suggested as an alternative owing to its nonslip nature and reproducibility in limited spaces. We explored whether the RHAP knot is noninferior to the square knot by assessing tensile strength. Methods We conducted 10 trials for each baseline and knot configuration, using 3–0 silk and 3–0 polyglactin 910 sutures. We compared tensile strength between knot configurations at the point of knot failure between slippage and breakage. Results Maximal failure strength (mean ± SD) in square knots was reached with 4-throw in both silk (30 ± 1.5 N) and polyglactin 910 (39 ± 12 N). For RHAP knots, maximal failure strength was reached at 5-throw for both silk (31 ± 1.5 N) and polyglactin 910 (41 ± 13 N). In both sutures, there were no strength differences between 3-throw square and 4-throw RHAP, between 4-throw square and 5-throw RHAP, or between 5-throw square and 6-throw RHAP knots. Polyglactin 910 sutures, in all knot configurations, were more prone to slippage than silk sutures (p < 0.001). Conclusion The difference in mean tensile strength could be attributed to the proportion of knot slippage versus breakage, which is material-dependent. Future studies can re-evaluate findings in monofilament sutures and objectively assess the reproducibility of square and RHAP knots in deep cavities. Our results indicate that RHAP knots composed of 1 extra throw provide equivalent strength to square knots and may be an alternative when performing hand-ties in limited cavities with either silk or polyglactin 910 sutures. PMID:28327276
Comparing the tensile strength of square and reversing half-hitch alternating post knots.
Wu, Vincent; Sykes, Edward A; Mercer, Dale; Hopman, Wilma M; Tang, Ephraim
2017-06-01
Square knots are the gold standard in hand-tie wound closure, but are difficult to reproduce in deep cavities, inadvertently resulting in slipknots. The reversing half-hitch alternating post (RHAP) knot has been suggested as an alternative owing to its nonslip nature and reproducibility in limited spaces. We explored whether the RHAP knot is noninferior to the square knot by assessing tensile strength. We conducted 10 trials for each baseline and knot configuration, using 3-0 silk and 3-0 polyglactin 910 sutures. We compared tensile strength between knot configurations at the point of knot failure between slippage and breakage. Maximal failure strength (mean ± SD) in square knots was reached with 4-throw in both silk (30 ± 1.5 N) and polyglactin 910 (39 ± 12 N). For RHAP knots, maximal failure strength was reached at 5-throw for both silk (31 ± 1.5 N) and polyglactin 910 (41 ± 13 N). In both sutures, there were no strength differences between 3-throw square and 4-throw RHAP, between 4-throw square and 5-throw RHAP, or between 5-throw square and 6-throw RHAP knots. Polyglactin 910 sutures, in all knot configurations, were more prone to slippage than silk sutures ( p < 0.001). The difference in mean tensile strength could be attributed to the proportion of knot slippage versus breakage, which is material-dependent. Future studies can re-evaluate findings in monofilament sutures and objectively assess the reproducibility of square and RHAP knots in deep cavities. Our results indicate that RHAP knots composed of 1 extra throw provide equivalent strength to square knots and may be an alternative when performing hand-ties in limited cavities with either silk or polyglactin 910 sutures.
Attar, Bijan Movahedian; Zalzali, Haidar; Razavi, Mohammad; Ghoreishian, Mehdi; Rezaei, Majid
2012-10-01
Epineural suturing is the most common technique used for peripheral nerve anastomosis. In addition to the foreign body reaction to the suture material, the surgical duration and difficulty of suturing in confined anatomic locations are major problems. We evaluated the effectiveness of fibrin glue as an acceptable alternative for nerve anastomosis in dogs. Eight adult female dogs weighing 18 to 24 kg were used in the present study. The facial nerve was transected bilaterally. On the right side, the facial nerve was subjected to epineural suturing; and on the left side, the nerve was anastomosed using fibrin adhesive. After 16 weeks, the nerve conduction velocity and proportion of the nerve fibers that crossed the anastomosis site were evaluated and compared for the epineural suture (right side) and fibrin glue (left side). The data were analyzed using the paired t test and univariate analysis of variance. The mean postoperative nerve conduction velocity was 29.87 ± 7.65 m/s and 26.75 ± 3.97 m/s on the right and left side, respectively. No statistically significant difference was found in the postoperative nerve conduction velocity between the 2 techniques (P = .444). The proportion of nerve fibers that crossed the anastomotic site was 71.25% ± 7.59% and 72.25% ± 8.31% on the right and left side, respectively. The histologic evaluation showed no statistically significant difference in the proportion of the nerve fibers that crossed the anastomotic site between the 2 techniques (P = .598). The results suggest that the efficacies of epineural suturing and fibrin gluing in peripheral nerve anastomosis are similar. Copyright © 2012 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.
Code of Federal Regulations, 2013 CFR
2013-01-01
... materially detracting from the appearance of the cantaloup; (g) Cracks when deep or not dry. Slight, dry cracks at the ends or in the sutures of the cantaloup shall not be considered damage; (h) Ground spot...
Code of Federal Regulations, 2014 CFR
2014-01-01
... materially detracting from the appearance of the cantaloup; (g) Cracks when deep or not dry. Slight, dry cracks at the ends or in the sutures of the cantaloup shall not be considered damage; (h) Ground spot...
... cuts is a small sticky strip called a butterfly bandage. It keeps the edges of a shallow ... help. Different kinds of materials — sutures, glue, and butterflies — need different kinds of care. The doctor probably ...
A survey of outcome of adjustable suture as first operation in patients with strabismus
Razmjoo, Hasan; Attarzadeh, Hosein; Karbasi, Najmeh; Najarzadegan, Mohammad Reza; Salam, Hasan; Jamshidi, Aliraza
2014-01-01
Background: Adjustable suture used for years to improve the outcome of strabismus surgery. We surveyed outcome of our patients with strabismus who underwent adjustable suture. Materials and Methods: This retrospective study was performed at Ophthalmology Centre of Feiz Hospital in Isfahan on 95 participants that candidate for adjustable suture strabismus surgery. Patients were divided into three age groups: Under 10 years, 10-19 years, and 20 years and over. Outcome of adjustable suture surgery consequence of residual postoperative deviation was divided into four groups: Excellent, good, acceptable, and unacceptable. Results: Out of 95 patients studied, 51 (53.7%) were males and 44 (46.3%) were females. The mean of deviation angles were 53.8 ± 17.9 PD (Prism dioptres) in alt XT, 44.5 ± 12 PD in alt ET and 52 ± 13.5 PD in const ET, 47.1 ± 13.1PD in cons XT, respectively. There was no significant difference between the groups (P = 0.051). Results of surgery were in 38 patients (40%) excellent, in 31 patients (32.6%) good, in 19 patients (20%) acceptable, and in 7 patients (7.4%) unacceptable. Seven (7.4%) patients required reoperation. Conclusions: In the present study, the frequency of re-operation was much lower than other similar studies (7.4% vs. 30-50%). This suggests that the adjustable technique that used in our study can be associated with lower reoperation than other adjustable techniques used in the other similar studies. PMID:25250293
Sztuczka, Ewa; Jackowski, Marek; Żukowska, Wioletta
2016-09-01
Wound healing is a complex and time-phased process. The occurrence of numerous negative conditions as well as external factors have a significant influence on the risk of potential complications. Preparing the patient for surgery, attention should be paid to a number of factors determining the proper healing process. The aim of the study was to compare the results of the early period of surgical wound healing process with access via laparotomy using techniques, which are self-adaptive sutures and mechanical staplers used for skin closure. The study included 120 patients divided into three groups, according to the degree of wound continence, in accordance with the CDC (Center for Disease Control and Prevention). Exclusion criteria based on objective analysis were applied for patients with a higher risk of complications. In all cases the skin layer was closed with monofilament suture or single-patient use stapler. A ten-day observation of the wound healing process was implemented. The study was randomized. In the case of patients groups identified as a "Clean Wound" and " Clean / Infected Wound" no significant differences were discovered. In the group "Contaminated/Infected Wound" significantly higher percentage of wound-healing complications were reported (p < 0.05) for which monofilament sutures was used. The study showed, that mechanical stapler is recommended for contaminated/infected surgical wounds due to significantly lower risk of complications. In the case of wounds divided as a "Clean" and "Clean/Infected" type of suturing material has no significant effect on wound healing.
Musani, Ali I; Jensen, Kurt; Mitchell, John D; Weyant, Michael; Garces, Katherine; Hsia, David
2012-04-01
Benign tracheal obstruction occurs for a variety of reasons. Bronchoscopic intervention includes silicone stent placement, which effectively maintains airway patency. Stent migration is a common complication, particularly when placed in the proximal trachea. We used a novel technique of securing tracheal stents with a percutaneous endoscopic gastrostomy tube fastener (PEG-TF) to prevent stent migration. The purpose of this study was to determine the feasibility of securing silicone stents in the proximal trachea with PEG-TF. Silicone stents were placed under general anesthesia by rigid bronchoscopy in 7 consecutive patients with inoperable benign proximal tracheal obstruction. PEG-TFs were placed under sterile conditions with direct bronchoscopic visualization. A needle was inserted through the anterior neck and silicone stent wall allowing stylet introduction of a T-fastener into the interior of the stent. The T-fastener was secured externally by a metal clamp and cotton pledget at the surface of the neck. Patients had routine outpatient follow-up and covered the external portion of the PEG-TF with a waterproof dressing when showering. All 7 PEG-TFs were placed without complications. The PEG-TFs were left in for 1 to 25 weeks. Complications of the PEG-TF included localized cellulitis and suture breakage. No stent migration occurred while the fastener was in place. Two stents were removed within 2 weeks due to patient's difficulty tolerating the stent. Securing silicone stents in the proximal trachea is feasible and may prevent stent migration, but further study and possible modification of the PEG-TF device are needed.
Hutchinson, Deborah R.; Klitgord, Kim D.; Tréhu, Anne M.; McBride, John H.; Nelson, K. D.
1990-01-01
Integration of magnetic anomaly analysis with COCORP deep reflection data from the southeastern United States provides three new constraints on the interpretation of the Brunswick and East Coast magnetic anomalies, as well as on the reflection data. These are as follows. (1) The source of the Brunswick anomaly lies within the deep crust. This anomaly is not caused by a Mesozoic rift basin, as proposed by some workers. (2) A simple, seaward-dipping, high- susceptibility slab model can explain both the Brunswick and East Coast magnetic anomalies. The along-strike change in character of the two anomalies results largely from a change in azimuth of the source body. (3) Beneath the southeastern United States, this source body dips south, lies immediately on the south flank of the prominent southward-dipping reflective zone revealed on COCORP surveys, and was previously associated with the Alleghanian suture between North America and Africa. These results imply that a dipping, highly magnetized zone in the upper plate of the Alleghanian suture is responsible for both the Brunswick and East Coast magnetic anomalies. The high- susceptibility material responsible for these anomalies might be mafic lower continental or oceanic crust thrust upward during Alleghanian continental collision, or mafic igneous material intruded into the upper plate of the suture zone during subsequent Mesozoic rifting, or both. The latter hypothesis implies that the Alleghanian suture acted, as a zone of weakness (a repository ?) which was reactivated to control the site of ultimate Atlantic rifting and possibly initial sea-floor spreading.
Matrices and scaffolds for drug delivery in dental, oral and craniofacial tissue engineering☆
Moioli, Eduardo K.; Clark, Paul A.; Xin, Xuejun; Lal, Shan; Mao, Jeremy J.
2010-01-01
Current treatments for diseases and trauma of dental, oral and craniofacial (DOC) structures rely on durable materials such as amalgam and synthetic materials, or autologous tissue grafts. A paradigm shift has taken place to utilize tissue engineering and drug delivery approaches towards the regeneration of these structures. Several prototypes of DOC structures have been regenerated such as temporomandibular joint (TMJ) condyle, cranial sutures, tooth structures and periodontium components. However, many challenges remain when taking in consideration the high demand for esthetics of DOC structures, the complex environment and yet minimal scar formation in the oral cavity, and the need for accommodating multiple tissue phenotypes. This review highlights recent advances in the regeneration of DOC structures, including the tooth, periodontium, TMJ, cranial sutures and implant dentistry, with specific emphasis on controlled release of signaling cues for stem cells, biomaterial matrices and scaffolds, and integrated tissue engineering approaches. PMID:17499385
Birth, Matthias; Markert, Uwe; Strik, Martin; Wohlschläger, Charlotte; Brugmans, Frederik; Gerberding, Jürgen; Bruch, Hans P
2002-01-15
In orthotopic liver transplantation the incidence of biliary complications is up to 49%. In view of the relative frequency of such complications despite seemingly good preconditions, method-related disadvantages of conventional suture must also be considered as a possible cause. These include perforating needle injury of the choledochal wall with at least temporary exposure of suture material in the lumen, suboptimal approximation of the mucosa, and an additional decrease in blood flow in the choledochal stumps as a result of suture-related tissue strangulation. Hence the search for alternative anastomosis techniques. To evaluate the surgical suitability of extramucosal titanium clips (Vascular Closure Staples; VCS) in comparison with conventional manual suture, a study was performed in 36 pigs, which were randomly assigned to 4 groups, each containing 9 animals. Choledochal excision was performed in 18 pigs and transection in the other 18 pigs; end-to-end anastomosis was then carried out, using a VCS stapler in half of the animals in each of these two groups and conventional manual suture in the other half. Pre- and postanastomotic blood flow was measured during the surgery with the aid of a laser Doppler flow meter. The long-term behavior of the closure techniques was ascertained by regular laboratory checks over the ensuing 6-month observation period, after which the pigs were killed so that the specimens could be harvested. Using medium-sized VCS clips, we were able to create a tension-free, everted biliary anastomosis with exact mucosal approximation and no narrowing of the lumen, and without any technical problems during the performance of the procedure. Measurements with the laser Doppler flow meter showed well-preserved anastomotic blood flow after clip reconstruction, with significantly higher perfusion values than after manual suture. The postoperative courses of the investigated laboratory parameters did not reveal any significant differences between the two methods. In contrast, histomorphometric evaluation showed wall thickness and thus fibrosis in the anastomosis region to be less in the clip group than in the suture group (median: 510 microm versus 660 microm, P<0.001). In the pigs in which clip anastomosis was used, there were no detectable anastomotic stenoses; in the pigs in which conventional suture was used, however, ultrasonography revealed five anastomoses with varying degrees of narrowing. Extramucosal VCS clip anastomosis not only offers potential advantages with respect to nonpenetrating and optimal mucosal contact, investigations in animals also show it to be superior to conventional manual suture as regards anastomotic blood flow and medium-term fibrosis formation. We believe that our data and the available literature warrant a clinical evaluation of this technique in appropriate studies.
Mori, Hirohito; Kobara, Hideki; Fujihara, Shintaro; Nishiyama, Noriko; Rafiq, Kazi; Oryu, Makoto; Fujiwara, Masao; Suzuki, Yasuyuki; Masaki, Tsutomu
2014-02-01
Endoscopic full-thickness resection (EFTR) requires a reliable full-thickness suturing device and an endoscopic counter-traction device to prevent the collapse of the digestive tract. The present study aimed to assess the reliability of newly developed flexible endoscopy suturing devices and the feasibility of pure EFTR. A total of 30 EFTRs were performed and allocated to three groups (N = 10 for each group). The full-thickness sutures were placed using over-the-scope clips (OTSCs), hand-sewn sutures, or the Double-arm-bar Suturing System (DBSS). Air leak tests were conducted in the three groups. The times required for the placement of one OTSC suture and single-stitch simple interrupted sutures (hand-sewn and DBSS sutures, respectively) were also compared. All 30 full-thickness sutures were completely and successfully placed. Regarding the air leak tests, the Mann-Whitney U test showed significant differences between OTSC and hand-sewn sutures (p = 0.003). There was also a significant difference between OTSC and DBSS sutures (p = 0.023). There was no significant difference between hand-sewn and DBSS sutures (p = 0.542). A significant difference was found in the suture time for single-stitch simple interrupted sutures among the OTSC, hand-sewn, and DBSS sutures. The Mann-Whitney U test revealed a significant difference between OTSC and hand-sewn sutures (p = 0.0001). There was no significant difference between OTSC and DBSS sutures (p = 0.533), while a significant difference was found between hand-sewn and DBSS sutures (p = 0.0001). Pure EFTR is feasible if the mechanical counter traction system is used to expand a small operative field and DBSS is used to make full-thickness sutures. The high safety of full-thickness resection and full-thickness suturing allows for clinical applications of this method.
Mechanical Strength of the Side-to-Side Versus Pulvertaft Weave Tendon Repair
Brown, Stephen H. M.; Hentzen, Eric R.; Kwan, Alan; Ward, Samuel R.; Fridén, Jan; Lieber, Richard L.
2010-01-01
Purpose The side-to-side (SS) tendon suture technique was designed to function as a repair that permits immediate post-operative activation and mobilization of a transferred muscle. This study was designed to test the strength and stiffness of the SS technique against a variation of the Pulvertaft (PT) repair technique. Methods Flexor digitorum superficialis (FDS) and flexor digitorum profundus (FDP) tendons were harvested from four fresh cadavers and used as a model system. Seven SS and six PT repairs were performed using the FDS as the donor and the FDP as the recipient tendon. For SS repairs, the FDS was woven through one incision in the FDP, and was joined with four cross-stitch running sutures down both sides, and one double-loop suture at each tendon free end; for PT repairs, FDS was woven through three incisions in FDP, joined with a double-loop suture at both ends of the overlap, and four evenly spaced mattress sutures between the ends. Tendon repairs were placed in a tensile testing machine, pre-conditioned and tested to failure. Results There were no statistically significant differences in cross-sectional area (p=0.99) or initial length (p=0.93) between SS and PT repairs. Therefore, all comparisons between methods were made using measures of loads and deformations, rather than stresses and strains.. All failures occurred in the repair region, rather than at the clamps. However, failure mechanisms were different between the two techniques—PT repairs failed by the suture knots either slipping or pulling through the tendon material, followed by the FDS tendon pulling through the FDP tendon; SS repairs failed by shearing of fibers within the FDS. Load at first failure (p < 0.01), ultimate load (p < 0.001), and repair stiffness (p < 0.05) were all significantly different between SS and PT techniques; in all cases the mean value for SS was higher than for PT. Discussion The SS repair, using a cross-stitch suture technique, was significantly stronger and stiffer compared to the PT repair using a mattress suture technique. This suggests that using SS repairs could enable patients to load the repair soon after surgery. Ultimately, this should reduce the risk of developing adhesions and result in improved functional outcome and fewer complications in the acute post-operative period. Future work will address the specific mechanisms (for example, suture-throw technique, tendon-weave technique) that underlie the improved strength and stiffness of the SS repair. PMID:20223604
Bidirectional lift of the anterior midcheek with Gore-Tex cable sutures.
Sasaki, Gordon H; Oberg, Kerby C; Kim, E Yoonah
2003-01-01
The reader is presumed to have a broad understanding of the anatomy of the anterior midface. After reading this article, the participant should be able to: Physicians may earn 1 hour of Category 1 CME credit by successfully completing the examination on the basis of material covered in this article. The examination begins on page 257. We have previously described a technique of anterior midface soft tissue repositioning using 2 cable sutures directed only in a superolateral direction. This technique achieves a more normal distribution of subcutaneous fat laterally over the malar bag prominence but does little to overcome central and medial hollowness in the palpebromalar and tear-trough areas. We describe an alteration of our original technique that introduces a vertical lift of the anterior midface soft tissue utilizing Gore-Tex, (W.L. Gore & Associates, Flagstaff, AZ) cable sutures while elevating the preperiosteal soft tissue. We used a transconjunctival approach to expose the postseptal fat, orbital rim, and arcus marginalis. Subperiosteal dissection over the orbital rim was performed to prepare a pocket for the malar fat pads. Using 6.5-cm Keith needles, we placed a braided suture medially, lateral to the location of the infraorbital nerve and foramen, and maneuvered it through the soft tissue until all signs of dimpling at the nasolabial line or upward distortion of the upper lip were removed. A Gore-Tex graft was introduced and seated in a cupped configuration that anchored the caudal fat pad at the nasolabial line. The medial fat pad and vascular pedicle were transposed over the orbital rim into the predissected pocket; the central fat pad was also fashioned into a pedicle and moved into its pocket. The Gore-Tex sutures were tightened, elevating the supraperiosteal soft tissue vertically. A second set of Gore-Tex sutures elevated the anterior midface soft tissue toward the deep temporal fascia. Between 1999 and 2002, 197 patients underwent bidirectional anterior midface lift with Gore-Tex sutures, combined with ancillary procedures. Use of the Gore-Tex cable sutures enabled improvement in the periorbitum, midcheek, and neck, as well as a more harmonious facial appearance in all patients, with few complications. The bidirectional cable-suture technique is simple, effective, and safe. It provides secure fixation and filling of the nasojugal hollow and improvement of the malar eminence. It is less effective in the periorbitum and does not seem to correct the recalcitrant nasolabial fold.
Busfield, Benjamin T; Glousman, Ronald E; McGarry, Michelle H; Tibone, James E; Lee, Thay Q
2008-05-01
Previous studies have shown comparable biomechanical properties of double-row fixation versus double-row fixation with a knotless lateral row. SutureBridge is a construct that secures the cuff with medial row mattress suture anchors and knotless lateral row fixation of the medial suture ends. Recent completely knotless constructs may lead to lesser clinical outcomes if the construct properties are compromised from lack of suture knots. A completely knotless construct without medial row knots will compromise the biomechanical properties in both cyclic and failure-testing parameters. Controlled laboratory study. Six matched pairs of cadaveric shoulders were randomized to 2 groups of double row fixation with SutureBridge: group 1 with medial row knots, and group 2 without medial row knots. The specimens were placed in a materials test system at 30 degrees of abduction. Cyclic testing to 180 N at 1 mm/sec for 30 cycles was performed, followed by tensile testing to failure at 1 mm/sec. Data included cyclic and failure data from the materials test system and gap data using a video digitizing system. All data from paired specimens were compared using paired Student t tests. Group 1 had a statistically significant difference (P < .05) for gap formation for the 1st (3.47 vs 5.05 mm) and 30th cycle (4.22 vs 8.10 mm) and at yield load (5.2 vs 9.1 mm). In addition, there was a greater energy absorbed (2805 vs 1648 N-mm), yield load (233 vs 183.1 N), and ultimate load (352.9 vs 253.9 N) for group 1. The mode of failure for the majority (4/6) of group 2 was lateral row failure, whereas all group 1 specimens failed at the clamp. Although lateral row knotless fixation has been shown not to sacrifice structural integrity of this construct, the addition of a knotless medial row compromises the construct leading to greater gapping and failure at lower loads. This may raise concerns regarding recently marketed completely knotless double row constructs.
Microsurgical techniques of anastomosis of the fallopian tubes.
Smith, R N; Minkler, D
1978-01-01
Microsurgical techniques of anastomosis of the fallopian tubes have been studied. This paper considers the present state of the art of sterilization reversal, the training and equipment required, the potential for the diffusion of knowledge concerning reversal techniques, and the implication of current research in reversibility of sterilization for the practicing gynecologist. A preoperative study should be done on any candidate for a procedure to restore patency to the fallopian tubes to rule out other possible causes of infertility. Also, preoperative counseling should include both partners. The operating microscope offers a great advantage in the repair of several types of tubal obstruction. Midsegment end-to-end anastomosis is carried out by 1st injecting a dye into the cavity to locate the area of obstruction. The area is excised using microdissection and the fallopian tube checked for patency with the dye solution. Anastomosis is accomplished by opposing the miscularis of the tube, avoiding the mucosa. 4 sutures are usually adequate for closure. Most feel that postoperative hydrotubation is of some value in monitoring tubal patency. An organized training program in a microsurgical laboratory is the prefered way for learning the techniques. Long-term results of the microsurgical techniques for tubal anastomosis are encouraging and represent an improvement over macroscopic techniques previously reported.
Spring-mediated distraction enterogenesis in-continuity.
Huynh, Nhan; Rouch, Joshua D; Scott, Andrew; Chiang, Elvin; Wu, Benjamin M; Shekherdimian, Shant; Dunn, James C Y
2016-12-01
Distraction enterogenesis has been investigated as a novel treatment for patients with short bowel syndrome (SBS) but has been limited by loss of intestinal length during restoration and need for multiple bowel surgeries. The feasibility of in-continuity, spring-mediated intestinal lengthening has yet to be demonstrated. Juvenile mini-Yucatan pigs underwent in-continuity placement of polycaprolactone (PCL) degradable springs within jejunum. Methods used to anchor the spring ends to the intestine included full-thickness sutures and a high-friction surface spring. Spring constant (k) was 6-15N/m. Bowel was examined for length and presence of spring at 1 to 4weeks. Animals tolerated in-continuity lengthening without bowel obstruction for up to 29days. In-continuity jejunum with springs demonstrated intestinal lengthening by 1.47-fold ±0.11. Five springs had detached prematurely, and lengthening could not be assessed. Histologically, in-continuity jejunum showed significantly increased crypt depth and muscularis thickness in comparison to normal jejunum. Self-expanding endoluminal springs placed in continuity could lengthen intestine without obstruction in a porcine model. This is the first study showing safety and efficacy of a self-expanding endoluminal device for distraction enterogenesis. This is proof-of-concept that in-continuity spring lengthening is feasible and demonstrates its therapeutic potential in SBS. Level 3. Copyright © 2016 Elsevier Inc. All rights reserved.
Endoscope-assisted laparoscopic repair of perforated peptic ulcers.
Lee, Kun-Hua; Chang, Hung-Chi; Lo, Chong-Jeh
2004-04-01
Laparoscopic repairs for perforated peptic ulcer (PPU) are likely to fail in patients with shock, gastric outlet obstruction, or large perforations. This prospective study was performed to evaluate a revised approach of laparoscopic repair with endoscopic assistance to treat these patients. Between April 2001 and February 2002, 30 consecutive patients with PPU were enrolled in this study. The mean age was 43.1 +/- 12.2 years. Male to female ratio was 27:2. One patient was excluded from laparoscopic repair due to a gastric outlet obstruction. The other 29 patients were managed according to a protocol of preoperative upper endoscopy and laparoscopic intracorporeal suture repair with an omental patch. The average operative time was 58.1 +/- 13.5 minutes (range, 36-96 min). The average diameter of perforation was 4.2 +/- 2.0 mm (range, 1-12 mm). The average time to resume oral fluids was 3.2 +/- 0.8 days (range, 2-8 days). The average hospital stay was 4.7 +/- 1.1 days (range, 3-10 days). There was no leakage or mortality. Most patients did not receive parenteral analgesics postoperatively. We conclude that endoscope-assisted laparoscopic repair for PPU is safe and effective. This revised technique allows surgeons to exclude patients who are likely to fail the laparoscopic repair.
Yu, Jianhua; Wu, Zhonghua; Xu, Youming; Li, Zhuo; Wang, Jiansong; Qi, Fan; Chen, Xiang
2011-09-01
• To report our experience with retroperitoneal laparoscopic dismembered pyeloplasty for pelvi-ureteric junction (PUJ) obstruction in children. • Between March 2007 and December 2009, 38 children with PUJ obstruction (mean age 8.3 years, range 3-14) underwent retroperitoneal laparoscopic dismembered pyeloplasty. • A ureteric catheter was inserted into the mid-ureter cystoscopically. During pyeloplasty, the proximal end of the ureteric catheter was extracorporeally sutured to the distal end of the JJ stent with silk. • The ureteric catheter was then pulled down and the stent was pulled antegrade into the ureter and bladder. • The approach was retroperitoneal in all patients except one who required open conversion. The overall mean operative time was 162 min (range 145-210 min) and this appeared to decrease with experience. Mean hospital stay was 4 days (range 3-7 days). • Mean follow-up was 20.2 months (range 6-32 months). Satisfactory drainage with decreased hydronephrosis was documented in all patients on ultrasonography and intravenous urography. • Our study shows that retroperitoneal laparoscopic dismembered pyeloplasty is a feasible and effective alternative to open pyeloplasty with a relatively minimal complication rate in children 3 years of age and older, but it should be undertaken by experienced laparoscopic surgeons. © 2011 THE AUTHORS. BJU INTERNATIONAL © 2011 BJU INTERNATIONAL.
The role of vertebrate models in understanding craniosynostosis.
Holmes, Greg
2012-09-01
Craniosynostosis (CS), the premature fusion of cranial sutures, is a relatively common pediatric anomaly, occurring in isolation or as part of a syndrome. A growing number of genes with pathologic mutations have been identified for syndromic and nonsyndromic CS. The study of human sutural material obtained post-operatively is not sufficient to understand the etiology of CS, for which animal models are indispensable. The similarity of the human and murine calvarial structure, our knowledge of mouse genetics and biology, and ability to manipulate the mouse genome make the mouse the most valuable model organism for CS research. A variety of mouse mutants are available that model specific human CS mutations or have CS phenotypes. These allow characterization of the biochemical and morphological events, often embryonic, which precede suture fusion. Other vertebrate organisms have less functional genetic utility than mice, but the rat, rabbit, chick, zebrafish, and frog provide alternative systems in which to validate or contrast molecular functions relevant to CS.
Okubo, Hirotaka; Kusano, Nozomu; Kinjo, Masaki; Kanaya, Fuminori
2015-01-01
In multi-strand suture methods consisting of several suture rows, the different length of core suture purchase between each suture row may affect the strength of repairs. We evaluated the influence of the different length of core suture purchase between each suture row on the strength of 6-strand tendon repairs. Rabbit flexor tendons were repaired by using a triple-looped suture technique in which the suture purchase length in each suture row was modified. Group 1, all lengths are 8-mm. Group 2, all lengths are 10-mm. Group 3, two are 10-mm and one is 8-mm. Group 4, one is 10-mm and two are 8-mm. The repaired tendons were subjected to load-to-failure test. The gap strength was significantly greater in Group 1 and Group 2 than in Group 3 and Group 4. This study demonstrates that maintaining equal core suture purchase lengths of each suture row increases the gap resistance.
Stefanidis, Dimitrios; Hope, William W; Scott, Daniel J
2011-07-01
The value of robotic assistance for intracorporeal suturing is not well defined. We compared robotic suturing with laparoscopic suturing on the FLS model with a large cohort of surgeons. Attendees (n=117) at the SAGES 2006 Learning Center robotic station placed intracorporeal sutures on the FLS box-trainer model using conventional laparoscopic instruments and the da Vinci® robot. Participant performance was recorded using a validated objective scoring system, and a questionnaire regarding demographics, task workload, and suturing modality preference was completed. Construct validity for both tasks was assessed by comparing the performance scores of subjects with various levels of experience. A validated questionnaire was used for workload measurement. Of the participants, 84% had prior laparoscopic and 10% prior robotic suturing experience. Within the allotted time, 83% of participants completed the suturing task laparoscopically and 72% with the robot. Construct validity was demonstrated for both simulated tasks according to the participants' advanced laparoscopic experience, laparoscopic suturing experience, and self-reported laparoscopic suturing ability (p<0.001 for all) and according to prior robotic experience, robotic suturing experience, and self-reported robotic suturing ability (p<0.001 for all), respectively. While participants achieved higher suturing scores with standard laparoscopy compared with the robot (84±75 vs. 56±63, respectively; p<0.001), they found the laparoscopic task more physically demanding (NASA score 13±5 vs. 10±5, respectively; p<0.001) and favored the robot as their method of choice for intracorporeal suturing (62 vs. 38%, respectively; p<0.01). Construct validity was demonstrated for robotic suturing on the FLS model. Suturing scores were higher using standard laparoscopy likely as a result of the participants' greater experience with laparoscopic suturing versus robotic suturing. Robotic assistance decreases the physical demand of intracorporeal suturing compared with conventional laparoscopy and, in this study, was the preferred suturing method by most surgeons. Curricula for robotic suturing training need to be developed.
Functional anatomy of human scalene musculature: rotation of the cervical spine.
Olinger, Anthony B; Homier, Phillip
2010-10-01
Actions of the scalene muscles include flexion and lateral flexion of the cervical spine and elevation of the first and second ribs. The cervical rotational qualities of the scalene muscles remain unclear. Textbooks and recent studies report contradictory findings with respect to the cervical rotational properties of the scalene muscles. The present study was designed to take a mechanical approach to determining whether the scalene muscles produce rotation of the cervical spine. The scalene muscles were isolated, removed, and replaced by a durable suture material. The suture material was attached at the origin and then passed through a hole on the corresponding rib near the central point of the insertion. The suture material was pulled down through the corresponding costal insertion hole to simulate contraction of each muscle. The simulated anterior, middle, and posterior scalene muscles, working independently and jointly, produced ipsilateral rotation of the cervical spine. The upper cervical spine rotated in the ipsilateral direction in response to the simulated muscle contraction. Findings were similar for the lower cervical spine with the exception of 2 specimens, which rotated contralaterally in response to the simulation. Experimental models of the scalene muscles are capable of producing ipsilateral rotation of the cervical spine. The findings of this study support the accepted main actions of the scalene muscles. The clinical applications for understanding the cervical rotational properties of the scalene muscles include the diagnosis, management, and treatment of cervical pain conditions as well as thoracic outlet syndrome. Copyright © 2010 National University of Health Sciences. Published by Mosby, Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Anderson, G. E.; Loo, S. (Inventor)
1985-01-01
A fluid leak indicator for detecting and indicating leaks in visually inaccessible fluid tubing joints, such as those obstructed by insulation includes a bag system and a wicking system surrounding or wrapping the joints under the visual obstructing material. Leaking fluid is collected in the bag or on the wicking material where it is conducted along the wicking material to a visily accessible capturing transparent indicator bulb for providing a visual indication of the leak without requiring a chemical change in the capturing indicator bulb.
The efficacy of a single continuous nylon suture for control of post keratoplasty astigmatism.
Van Meter, W
1996-01-01
PURPOSE: Post operative adjustment of a single continuous suture is an effective means of reducing post keratoplasty astigmatism. This study evaluates post keratoplasty keratometry following suture adjustment with an adjusted suture in place and after the suture is removed. METHODS: Average keratometric astigmatism was measured over 24 months time in 26 patients with an adjusted continuous suture and 24 patients with a continuous suture that was not adjusted. Average keratometry in 43 patients with an adjusted continuous suture was compared with 37 patients with combined continuous and interrupted sutures. Finally, suture out astigmatism in 19 adjusted patients was compared to six patients with no adjustment. RESULTS: There was an increase in average corneal astigmatism over two years of 2.2 diopters in the adjusted group and 1.7 diopters in the non-adjusted group with sutures in place. One year following surgery, average keratometry flattened from 47.5 to 42.9 diopters in the adjusted continuous group and from 47.0 to 46.0 diopters in the group with combined continuous and interrupted sutures. Following suture removal, average astigmatism in patients who had suture adjustment was 4.4 diopters +/- 2.5 diopters (range 1-10 diopters), and 6.01 diopters (range 4-7) in the non-adjusted group. CONCLUSIONS: Average post keratoplasty astigmatism increases after a continuous suture is adjusted but the increase is comparable to patients with acceptable astigmatism who do not require adjustment. More progressive corneal flattening over 12 months time is seen with a continuous suture than which combined sutures. Average suture out astigmatism was 4.0 diopters following suture adjustment, compared to an average of 8.4 diopters prior to adjustment. Images FIGURE 1 FIGURE 2 FIGURE 3 FIGURE 4 FIGURE 7A FIGURE 7B PMID:8981721
Bridging suture makes consistent and secure fixation in double-row rotator cuff repair.
Fukuhara, Tetsutaro; Mihata, Teruhisa; Jun, Bong Jae; Neo, Masashi
2017-09-01
Inconsistent tension distribution may decrease the biomechanical properties of the rotator cuff tendon after double-row repair, resulting in repair failure. The purpose of this study was to compare the tension distribution along the repaired rotator cuff tendon among three double-row repair techniques. In each of 42 fresh-frozen porcine shoulders, a simulated infraspinatus tendon tear was repaired by using 1 of 3 double-row techniques: (1) conventional double-row repair (no bridging suture); (2) transosseous-equivalent repair (bridging suture alone); and (3) compression double-row repair (which combined conventional double-row and bridging sutures). Each specimen underwent cyclic testing at a simulated shoulder abduction angle of 0° or 40° on a material-testing machine. Gap formation and tendon strain were measured during the 1st and 30th cycles. To evaluate tension distribution after cuff repair, difference in gap and tendon strain between the superior and inferior fixations was compared among three double-row techniques. At an abduction angle of 0°, gap formation after either transosseous-equivalent or compression double-row repair was significantly less than that after conventional double-row repair (p < 0.01). During the 30th cycle, both transosseous-equivalent repair (p = 0.02) and compression double-row repair (p = 0.01) at 0° abduction had significantly less difference in gap formation between the superior and inferior fixations than did conventional double-row repair. After the 30th cycle, the difference in longitudinal strain between the superior and inferior fixations at 0° abduction was significantly less with compression double-row repair (2.7% ± 2.4%) than with conventional double-row repair (8.6% ± 5.5%, p = 0.03). Bridging sutures facilitate consistent and secure fixation in double-row rotator cuff repairs, suggesting that bridging sutures may be beneficial for distributing tension equally among all sutures during double-row repair of rotator cuff tears. Copyright © 2017 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.
The Medial Stitch in Transosseous-Equivalent Rotator Cuff Repair: Vertical or Horizontal Mattress?
Montanez, Anthony; Makarewich, Christopher A; Burks, Robert T; Henninger, Heath B
2016-09-01
Despite advances in surgical technique, rotator cuff repair retears continue to occur at rates of 10%, 22%, and 57% for small, medium, and large tears, respectively. A common mode of failure in transosseous-equivalent rotator cuff repairs is tissue pullout of the medial mattress stitch. While the medial mattress stitch has been studied extensively, no studies have evaluated a vertical mattress pattern placed near the musculotendinous junction in comparison with a horizontal mattress pattern. Vertical mattress stitches will have higher load to failure and lower gapping compared with horizontal mattress stitches in a transosseous-equivalent rotator cuff repair. Controlled laboratory study. Double-row transosseous-equivalent rotator cuff repairs were performed in 9 pairs of human male cadaveric shoulders (mean age ± SD, 58 ± 10 years). One shoulder in each pair received a medial-row suture pattern using a vertical mattress stitch, and the contralateral shoulder received a horizontal mattress. Specimens were mounted in a materials testing machine and tested in uniaxial tensile deformation for cyclic loading (500 cycles at 1 Hz to 1.0 MPa of effective stress), followed by failure testing carried out at a rate of 1 mm/s. Construct gapping and applied loads were monitored continuously throughout the testing. Vertical mattress sutures were placed in 5 right and 4 left shoulders. Peak cyclic gapping did not differ between vertical (mean ± SD, 2.8 ± 1.1 mm) and horizontal mattress specimens (3.0 ± 1.2 mm) (P = .684). Vertical mattress sutures failed at higher loads compared with horizontal mattress sutures (568.9 ± 140.3 vs 451.1 ± 174.3 N; P = .025); however, there was no significant difference in failure displacement (8.0 ± 1.6 vs 6.0 ± 2.1 mm; P = .092). Failure stiffness did not differ between the suture patterns (P = .204). In transosseous-equivalent rotator cuff repairs near the musculotendinous junction, a vertical mattress suture used as the medial stitch has a higher load to failure but no difference in gapping compared with a horizontal mattress pattern. A vertical mattress suture may offer enhanced strength of repair for transosseous-equivalent repairs. © 2016 The Author(s).
Suture Coding: A Novel Educational Guide for Suture Patterns.
Gaber, Mohamed; Abdel-Wahed, Ramadan
2015-01-01
This study aims to provide a helpful guide to perform tissue suturing successfully using suture coding-a method for identification of suture patterns and techniques by giving full information about the method of application of each pattern using numbers and symbols. Suture coding helps construct an infrastructure for surgical suture science. It facilitates the easy understanding and learning of suturing techniques and patterns as well as detects the relationship between the different patterns. Guide points are fixed on both edges of the wound to act as a guideline to help practice suture pattern techniques. The arrangement is fixed as 1-3-5-7 and a-c-e-g on one side (whether right or left) and as 2-4-6-8 and b-d-f-h on the other side. Needle placement must start from number 1 or letter "a" and continue to follow the code till the end of the stitching. Some rules are created to be adopted for the application of suture coding. A suture trainer containing guide points that simulate the coding process is used to facilitate the learning of the coding method. (120) Is the code of simple interrupted suture pattern; (ab210) is the code of vertical mattress suture pattern, and (013465)²/3 is the code of Cushing suture pattern. (0A1) Is suggested as a surgical suture language that gives the name and type of the suture pattern used to facilitate its identification. All suture patterns known in the world should start with (0), (A), or (1). There is a relationship between 2 or more surgical patterns according to their codes. It can be concluded that every suture pattern has its own code that helps in the identification of its type, structure, and method of application. Combination between numbers and symbols helps in the understanding of suture techniques easily without complication. There are specific relationships that can be identified between different suture patterns. Coding methods facilitate suture patterns learning process. The use of suture coding can be a good approach to the construction of an infrastructure of surgical suture science and the facilitation of the understanding and learning of suture pattern techniques. Copyright © 2015 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.
Batman, C; Ozdamar, Y; Mutevelli, S; Sonmez, K; Zilelioglu, G; Karakaya, J
2009-06-01
To describe the use of tissue glue to close scleral and conjunctival wounds, and to compare the clinical outcomes using tissue glue and vicryl suture for closing these areas in conventional 20-gauge (G) vitrectomy. Thirty eyes of 30 patients were included in this study. The indications for vitreoretinal surgery were diabetic vitreous haemorrhage with severe vitreoretinal traction in 10 eyes, retinal detachment and proliferative vitreoretinopathy in 14 eyes, and vitreous opacity in 6 eyes. Tissue glue (Tisseel, Baxter AG Industries, Vienna, Austria) was used to attach scleral and conjunctival wounds in 15 eyes and vicryl sutures in 15 eyes. The patients were allotted into two subgroups as tissue glue group (TG) and vicryl suture group (VG). The sclerotomy sites were evaluated with ultrasound biomicroscopy (UBM) postoperatively in TG. Follow-up period was 2 months. The groups were statistically compared for ocular signs and symptoms by Mann-Whitney U-test. No scleral wound leakage and conjunctival reattachment were observed at the end of the surgical procedure and during the follow-up period. No adverse effects were seen in TG. Abnormal fibrous ingrowth was not detected at the sclerotomy sites by means of UBM in TG. Patient comfort was significantly higher in TG than VG (P<0.05). Tissue glue has no adverse effects on ocular tissue and can be used as a substitute for suture materials, and the use of tissue glue decreases patient symptoms during the postoperative period after 20-G vitrectomy. Tissue glue can enable to perform sutureless surgery in the conventional 20-G vitrectomy.
One of the Earliest Accounts of Head Wounds in Firdaws al-Ḥikma by al-Ṭabarī from the 9th Century.
Acıduman, Ahmet; Tuzcu, Kemal; Belen, Deniz
2017-11-01
To present the first Arabic text on suturing scalp wounds. A related section entitled "On the wounds in the head" from the book Firdaws al-Ḥikma (Paradise of the Wisdom) written by al-Ṭabarī in the 9th century was identified and analyzed. This work was one of the earliest medical compendiums in the Islamic world during the medieval period. A printed copy of Firdaws al-Ḥikma edited by Muḥammad Zubayr al-Ṣiddīqī was examined, and findings were compared with relevant knowledge in the literature. A notable part of this text is based on appropriate closure of scalp wounds using sutures. Before this work, only the well-known Indian medical book Suśruta-Saṃhitā had mentioned closure of scalp wounds using sutures. In his work, al-Ṭabarī recommended using materials made of silk or linen for suturing. He additionally proposed some recipes that have a coating feature that prevents bleeding from the wound after it was closed properly. He also dealt with persistent swelling and provided formulas for solving the problem with special compositions. Firdaws al-Ḥikma is a noteworthy work in the history of medicine, and it includes a unique chapter on head wounds. To the best of our knowledge, this is the first mention of suturing scalp cuts in Arabic literature and the second reference in medical literature after the Indian work Suśruta-Saṃhitā. Copyright © 2017 Elsevier Inc. All rights reserved.
A rare case of Mirizzi syndrome due to pure calcium carbonate stones (Limy Bile).
Gilani, Nooman; Hanif, Muhammad Farooq; Karasek, Veronika
2016-06-01
We report the first case of Mirizzi syndrome in a patient who presented with biliary obstruction caused by pure calcium carbonate stones. A 61 years old male with history of portal vein thrombosis presented with rash, nausea and jaundice. An ultrasound of biliary tree showed gallstones with dilatation of hepatic duct and intrahepatic biliary tree. There was suspicion of a stone in proximal CBD. CT scan showed an opaque gallbladder with dense radio-opaque material in its lumen. An ERCP was then performed revealing external common hepatic duct obstruction at the neck of the gallbladder. A plastic biliary stent was placed across the obstruction, followed by a cholecystectomy. Resected gallbladder specimen revealed thick whitish paste like material, and formed stones filling the gallbladder lumen. Laboratory testing showed this material to be composed of 100% calcium carbonate crystals.
[CLINICAL CHARACTERISTIC OF POSTOPERATIVE STATE OF CICATRICIALLY-CHANGED CUTANEOUS TISSUES].
Loza, Kh O; Stavytskyi, S O; Loza, E O; Voloshina, L I; Avetikov, D S
2016-04-01
Abstract Comparison of postoperative kinds of cicatrix was conducted in 60 patients, depending on the suture material applied. Best conditions for the operative wound healing, achievement of more esthetic normotrophic cicatrix were guaranteed by application of a cutaneous adhesive.
Comparison between suture anchor and transosseous suture for the modified-Broström procedure.
Cho, Byung-Ki; Kim, Yong-Min; Kim, Dong-Soo; Choi, Eui-Sung; Shon, Hyun-Chul; Park, Kyoung-Jin
2012-06-01
This prospective, randomized study was conducted to compare clinical outcomes of the modified Broström procedure using suture anchor or transosseous suture technique for chronic ankle instability. Forty patients were followed for more than 2 years after modified Broström procedure. Twenty procedures using a suture anchor and 20 procedures using a transosseous suture were performed by one surgeon. The clinical evaluation consisted of the Karlsson scale and the Sefton grading system. Talar tilt and anterior talar translation were measured on anterior and varus stress radiographs. The Karlsson scale had improved significantly to 90.8 points in the suture anchor group, and to 89.2 points in the transosseous suture group. According to Sefton grading system, 18 patients (90%) in suture anchor group and 17 patients (85%) in transosseous suture group achieved satisfactory results. The talar tilt angle and anterior talar translation improved significantly to 5.9 degrees and 4.2 mm in suture anchor group, and to 5.4 degrees and 4.1 mm in transosseous suture group, respectively. No significant differences existed in clinical and functional outcomes between the two techniques for ligament reattachment. Both modified Broström procedures using the suture anchor and transosseous suture seem to be effective treatment methods for chronic lateral ankle instability.
COCORULLO, G.; TUTINO, R.; FALCO, N.; SALAMONE, G.; FONTANA, T.; LICARI, L.; GULOTTA, G.
2016-01-01
Introduction The terminal ileum is the most involved tract in Crohn’s disease. The obstruction in this location is the most frequent complication. Acute or chronic presentations can occur. Surgery finds a role in the management of chronic strictures and in acute clinical presentations with complications not improving with conservative therapy. Patients and methods We investigate the outcome of patients with obstruction of the ileo-cecal bowel tract laparoscopically managed. It was analyzed the average operative time (OT), the conversion rate and the occurrence of re-operation due to surgical complications. Results 21 patients underwent an ileocecal resection for complicated Crohn’s disease between January 2013 and December 2014. The admissions were performed in emergency in 42% of patients. The pre-intervention hospital stay was 5.8 (Sd 6.23). The mean operative time was 154 min (Sd 41). 28% of the procedures were converted to open surgery. The average hospital stay was 10 days (Sd 5) in uncomplicated patients. The morbidity rate was 28%. In 19% of cases a re-intervention was needed due to anastomotic leakage (3pts) and one hemoperitoneum for bleeding from the suture line. Discussion Laparoscopy seems an affordable technique in the management of obstructive pattern of Crohn’s disease. It should be the preferable approach in young patients that probably will be submitted to subsequent surgery for the same disease; in fact, the reduced adhesions formation provided by the less bowel manipulation make easy the subsequent access. Older patients had usually more post-operative morbidity and mortality mostly due to pre-existing conditions; if possible in these patients the treatment should be medical. PMID:28098059
Robotic repair of a right-sided Bochdalek hernia: a case report and literature review.
Jambhekar, Amani; Robinson, Shawn; Housman, Brian; Nguyen, James; Gu, Kevin; Nakhamiyayev, Vadim
2018-06-01
Bochdalek hernias (BHs) are usually diagnosed in the neonatal period, occurring in 1/2200-1/12,500 live births. There are few reported cases of BHs in adults. Robotic repair has not been described in current literature as opposed to the laparoscopic approach. Here we present a case of an adult with clinical signs of bowel obstruction secondary to a BH which was repaired using a robotic approach. A 74-year-old gentleman with past medical history of benign prostatic hyperplasia presented to the emergency department with a 1-week history of nausea, vomiting, diarrhea, and decline in appetite. Computed tomography (CT) imaging of the chest and abdomen revealed elevation of the right hemidiaphragm and evidence of small bowel obstruction. The patient was managed conservatively with nasogastric tube placement and bowel rest. He underwent colonoscopy which could not be completed secondary to a transverse colon stricture which was confirmed by barium enema. Upon repeat CT imaging, the patient was found to have herniated colon through a right-sided diaphragmatic hernia which caused colonic narrowing. The patient's intestinal obstruction improved clinically with continued conservative management and he underwent robotic repair of a right posterior diaphragmatic hernia. The hernia defect was closed with interrupted figure of eight Ethibond sutures. A right-sided chest tube was placed. Intraoperatively, the herniated proximal transverse colon was noted to be ischemic and a right hemicolectomy was performed. He recovered well and was discharged home on postoperative day 5. Congenital diaphragmatic hernias usually present in the neonatal period and are rare in adults. Operative repair is recommended and laparoscopic repair has been described. Based on the existing literature regarding laparoscopic repair and the current case report, robotic repair also appears to be a viable and safe option.
Ono, Y.; Woodmass, J. M.; Nelson, A. A.; Boorman, R. S.; Thornton, G. M.
2016-01-01
Objectives This study evaluated the mechanical performance, under low-load cyclic loading, of two different knotless suture anchor designs: sutures completely internal to the anchor body (SpeedScrew) and sutures external to the anchor body and adjacent to bone (MultiFIX P). Methods Using standard suture loops pulled in-line with the rotator cuff (approximately 60°), anchors were tested in cadaveric bone and foam blocks representing normal to osteopenic bone. Mechanical testing included preloading to 10 N and cyclic loading for 500 cycles from 10 N to 60 N at 60 mm/min. The parameters evaluated were initial displacement, cyclic displacement and number of cycles and load at 3 mm displacement relative to preload. Video recording throughout testing documented the predominant source of suture displacement and the distance of ‘suture cutting through bone’. Results In cadaveric bone and foam blocks, MultiFIX P anchors had significantly greater initial displacement, and lower number of cycles and lower load at 3 mm displacement than SpeedScrew anchors. Video analysis revealed ‘suture cutting through bone’ as the predominant source of suture displacement in cadaveric bone (qualitative) and greater ‘suture cutting through bone’ comparing MultiFIX P with SpeedScrew anchors in foam blocks (quantitative). The greater suture displacement in MultiFIX P anchors was predominantly from suture cutting through bone, which was enhanced in an osteopenic bone model. Conclusions Anchors with sutures external to the anchor body are at risk for suture cutting through bone since the suture eyelet is at the distal tip of the implant and the suture directly abrades against the bone edge during cyclic loading. Suture cutting through bone may be a significant source of fixation failure, particularly in osteopenic bone. Cite this article: Y. Ono, J. M. Woodmass, A. A. Nelson, R. S. Boorman, G. M. Thornton, I. K. Y. Lo. Knotless anchors with sutures external to the anchor body may be at risk for suture cutting through osteopenic bone. Bone Joint Res 2016;5:269–275. DOI: 10.1302/2046-3758.56.2000535. PMID:27357383
Ono, Y; Woodmass, J M; Nelson, A A; Boorman, R S; Thornton, G M; Lo, I K Y
2016-06-01
This study evaluated the mechanical performance, under low-load cyclic loading, of two different knotless suture anchor designs: sutures completely internal to the anchor body (SpeedScrew) and sutures external to the anchor body and adjacent to bone (MultiFIX P). Using standard suture loops pulled in-line with the rotator cuff (approximately 60°), anchors were tested in cadaveric bone and foam blocks representing normal to osteopenic bone. Mechanical testing included preloading to 10 N and cyclic loading for 500 cycles from 10 N to 60 N at 60 mm/min. The parameters evaluated were initial displacement, cyclic displacement and number of cycles and load at 3 mm displacement relative to preload. Video recording throughout testing documented the predominant source of suture displacement and the distance of 'suture cutting through bone'. In cadaveric bone and foam blocks, MultiFIX P anchors had significantly greater initial displacement, and lower number of cycles and lower load at 3 mm displacement than SpeedScrew anchors. Video analysis revealed 'suture cutting through bone' as the predominant source of suture displacement in cadaveric bone (qualitative) and greater 'suture cutting through bone' comparing MultiFIX P with SpeedScrew anchors in foam blocks (quantitative). The greater suture displacement in MultiFIX P anchors was predominantly from suture cutting through bone, which was enhanced in an osteopenic bone model. Anchors with sutures external to the anchor body are at risk for suture cutting through bone since the suture eyelet is at the distal tip of the implant and the suture directly abrades against the bone edge during cyclic loading. Suture cutting through bone may be a significant source of fixation failure, particularly in osteopenic bone.Cite this article: Y. Ono, J. M. Woodmass, A. A. Nelson, R. S. Boorman, G. M. Thornton, I. K. Y. Lo. Knotless anchors with sutures external to the anchor body may be at risk for suture cutting through osteopenic bone. Bone Joint Res 2016;5:269-275. DOI: 10.1302/2046-3758.56.2000535. © 2016 Lo et al.
NASA Technical Reports Server (NTRS)
Anderson, George E. (Inventor); Loo, Shu (Inventor)
1989-01-01
A fluid leak indicator (30) for detecting and indicating leaks in visually inaccessible fluid tubing joints (20, 21), such as those obstructed by insulation (24), includes a bag system (25) and a wicking system (30) surrounding or wrapping the joints (20, 21) under the visual obstructing material (24). Leaking fluid is collected in the bag (25) or on the wicking material (34) where it is conducted along the wicking material (34) to a visibly accessible capturing transparent indicator bulb (35) for providing a visual indication of the leak without requiring a chemical change in the capturing indicator bulb (35).
Liu, Sean Shih-Yao; Xu, Haisong; Sun, Jun; Kontogiorgos, Elias; Whittington, Patrick R; Misner, Kenner G; Kyung, Hee-Moon; Buschang, Peter H; Opperman, Lynne A
2013-08-01
Suture expansion stimulates bone growth to correct craniofacial deficiencies but has a high potential of treatment relapse. The objective of this study was to investigate whether there is a dose-dependent relationship between the recombinant human bone morphogenetic protein-2 (rhBMP-2) and bone formation during suture expansion. Fifty 6-week-old male New Zealand white rabbits were randomly assigned to 5 groups to receive 0 (control), 0.01, 0.025, 0.1, or 0.4 mg/mL of rhBMP-2 delivered by absorbable collagen sponge placed over the interfrontal suture. The suture was expanded for 33 days by 200 g of constant force via a spring anchored with 2 miniscrew implants. Distance of suture expansion, suture volume, and cross-sectional area after expansion were measured using radiographs with bone markers and microcomputed tomography. Suture widths and mineralization appositional rates were calculated based on the widths between bone labels under an epifluorescent microscope. Software (Multilevel Win 2.0; University of Bristol, Bristol, United Kingdom) was used to model distance of suture expansion over time as polynomials to compare group differences. Wilcoxon signed rank tests were performed to compare the suture volume and cross-sectional area, mineral apposition rate, and suture width between groups. The significance level was set at P = 0.05. Whereas the sutures were expanded in all groups, sutures were expanded by significantly greater amounts in the control and the 0.01 mg/mL groups without fusing the sutures than in the 0.025, 0.1, and 0.4 mg/mL groups with fusing sutures. Compared with the controls, the 0.01 mg/mL group showed significantly lower suture volumes, cross-sectional areas, and suture widths after expansion. The mineral apposition rate was significantly higher in the 0.01 mg/mL group than in the controls from days 10 to 30. The 0.01 mg/mL dose of rhBMP-2 delivered by absorbable collagen sponge can stimulate bone formation at the bony edges of the suture during suture expansion; however, higher concentrations cause suture fusion. With an appropriate concentration, rhBMP-2 might facilitate suture expansion for clinical uses. Copyright © 2013 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Cameron, Bruce D.; Joos, Karen M.; Shen, Jin-Hui
1996-05-01
Purpose: To develop a simple suture lysis technique for post-trabeculectomy examinations under anesthesia since slit lamp laser suture lysis in the clinic cannot be performed on infants and young children. Methods: An argon endolaser probe lysed 10-0 nylon suture through conjunctiva harvested from human cadaver eyes. Since suture lysis failed with the thick Hoskins lens, clear plastic from the suture package compressed the conjunctiva. The conjunctiva was examined histologically. Results: Argon laser suture lysis (250 mW, 0.1 sec, 488 - 514 nm) was achieved without conjunctival damage. Conclusion: The argon endolaser probe is effective for suture lysis when the slit lamp cannot be used.
Liu, Lei; Jiang, Yunyao; Boyce, Mary; Ortiz, Christine; Baur, Jeffery; Song, Juha; Li, Yaning
2017-06-14
Irregular interdigitated morphology is prevalent in biological sutures in nature. Suture complexity index has long been recognized as the most important morphological parameter to govern the mechanical properties of biological sutures. However, the suture complexity index alone does not reflect all aspects of suture morphology. The goal of this investigation was to determine that besides suture complexity index, whether the degree of morphological irregularity of biological sutures has influences on the mechanical properties, and if there is any, how to quantify these influences. To explore these issues, theoretical and finite element (FE) suture models with the same suture complexity index but different levels of morphological irregularity were developed. The quasi-static stiffness, strength for damage initiation and post-failure process of irregular sutures were studied. It was shown that for the same suture complexity index, when the level of morphological irregularity increases, the overall strain to failure will increase while tensile stiffness is retained; also, the total energy to fracture increases with a sacrifice in strength to damage initiation. These results reveal that morphological irregularity is another important independent parameter to govern and balance the mechanical properties of biological sutures. Therefore, from the mechanics point of view, the prevalence of irregular suture morphology in nature is a merit, not a defect. Copyright © 2017 Elsevier Ltd. All rights reserved.
Reyes-Zamorano, Jesús
2014-01-01
Gastric volvulus can be classified according to etiology as primary or secondary, according to anatomy as or mesenteroaxial, and according to onset as acute or chronic. Management of secondary gastric volvulus acute should always be surgery and the choice of surgical procedure for treatment is chosen according to etiology. Adherolysis and extraction of foreign bodies (suture, mesh, and gastric band) are important in those cases associated with previous abdominal surgery. Nissen fundoplication is a safe and effective procedure. Severe late complications of laparoscopic Nissen fundoplication are extremely rare occurrences. Among the reported complications is gastric volvulus. Presentation of two cases and review of literature. Two cases of acute gastric volvulus secondary to laparoscopic Nissen fundoplication presenting with epigastric pain and nonproductive retching and treated by laparoscopy are described. Symptoms upon presentation, incidence, diagnosis, treatment and predisposing factors to gastric volvulus postfundoplication are discussed. Gastric volvulus rarely occurs as a complication of Nissen fundoplication with an incidence similar to others of late complications. The described mechanisms that originate gastric volvulus postfundoplication are related to adhesions, foreign bodies as suture (polyester), gastrostomy tubes and mesh, gastropexy and internal gastric herniation through a "transfundoplication" window. A high index of suspicion is required in those patients presenting with acute symptoms of gastric obstruction in the first year following laparoscopic Nissen fundoplication. Laparoscopic approach is safe with or without gastropexy, always correcting the underlying mechanisms that cause gastric volvulus.
Importance of the levator labii alaeque nasi muscle in dorsal septal deviations.
Tellioğlu, Ali Teoman; Özakpinar, Hülda Rifat; Cakir, Bariş; Tekdemir, Ibrahim
2011-03-01
Deviated cartilages structures of the nose can be affected by nasal muscles, and deviation becomes conspicuous when the patient smiles. This condition depends on activity of nasal muscles, particularly the levator labii alaeque nasi muscle. A total of 124 septorhinoplasty operations were performed to correct dorsal concave septal deviation between 2005 and 2009 years. The 70 women and 54 men included in the study had an average age of 28 years. The average follow-up period was 12 months. Open septorhinoplasty was preferred in all cases. The medial part of the levator labii alaeque nasi muscle was extensively dissected from the lateral crus and surrounding tissues. The lateral crura of the alar cartilages were separated from the upper lateral cartilages in the scroll area. The dorsal septal deviation was corrected by combination of bilateral spreader grafts, which reinforced cartilage with horizontal control sutures. Early postoperative period was uneventful. Nasal obstruction was reduced after surgery, and significant subjective postoperative improvements were observed in all patients. Comparison of preoperative and postoperative photographs demonstrated improved dorsal nasal contour. Revision operation was performed in 3 cases. The corrected septal cartilage was in a good position in all revised cases; therefore, septal surgery was not performed in the revision operations. In conclusion, surgical disruption of the anatomic relationship between the muscle with the dorsal septal cartilage and reinforcement of the dorsal septal cartilage with spreader grafts and horizontal control sutures can decrease risk of recurrence.
Laparoscopic Band-Separated One Anastomosis Gastric Bypass.
Ospanov, Oral B
2016-09-01
This video demonstrates laparoscopic band-separated one anastomosis gastric bypass-combining the advantages of banding and gastric bypass without stapler and cutter use. This is basically a gastrojejunal loop bypass above an obstructive band in the upper stomach. An adjustable low pressure "Medsil" gastric band was introduced in the abdomen and retracted through the retrogastric tunnel. The front wall of the stomach below the band was displaced in the upward direction through the ring band, increasing the size of the anterior portion of the stomach pouch so that a gastroenteroanastomosis could be created at this point. Gastro-gastric sutures were placed to create a gastro-gastric plication around the band and hold it in position. The band tubing was exteriorized and connected to a special port, which was secured to the abdominal wall fascia. A jejunal loop was created about 200 cm from the ligament of Treitz and anastomosed to the gastric pouch by hand using Vicryl 2/0 sutures. Between November 2015 and February 2016, the study was performed on 10 patients. The average operating time for all cases was 75 min (range 63-87). There was no morbidity or mortality. No complications were observed, including band erosion and band infection. Operation costs were about $2000 lower with this method than with standard gastric bypass surgery. Postop the patients lost weight by 3-4 kg per month. Preliminary results show that laparoscopic band-separated one anastomosis gastric bypass have feasibility, safety, efficacy, and reduced operating costs.
Sayhan, Salih; Guvencer, Mustafa; Ozer, Ercan; Arda, Mehmet Nuri
2012-01-01
Obstruction of superior sagittal sinus (SSS) and collateral bridging veins is a well-known reason of postoperative brain edema and brain infarct, however, morphometric anatomic studies done in the light of surgical landmarks aren't sufficient in number. Object of this study is to describe venous structures related to SSS with silicon injected cadaveric models. This study was on 6 silicon injected cadaveric heads at Anatomy Department. Duramater was removed and veins on parasagittal area were examined. SSS morphology, veins draining into SSS, their size, number and distance were evaluated. Mean vein number draining into SSS is 2.9±1.5 at anterior to coronal suture (CS), between CS and vertex is 3.2±0.8, between vertex and lambdoid suture (LS) is 2.3±0.9, between LS and confluens sinuum 0.3±0.5. There was no statically difference between right and left sides (p=0.140, p > 0.05). Diameter of veins was 2.4±1.0 mm at anterior to CS, 3.0±1.2 mm at between CS and vertex, 2.4±0.7 mm at between vertex and LS, and 2.2±0.5 mm at between LS and confluens sinuum. Knowing details of anatomic structures of SSS and venous structures draining into it may protect the patients from many surgical complications. SSS and related structures with surgical landmarks are valuable for neurosurgeons.
Wongkietkachorn, Apinut; Rhunsiri, Peera; Boonyawong, Pangpoom; Lawanprasert, Attaporn; Tantiphlachiva, Kasaya
2016-01-01
Tutoring in suturing was developed to compensate for a shortage of suturing cases. The objective of this study was to compare ideal suturing score (ISS; 9 points), suturing time (min:sec), and suture placement error (mm) between medical students completing the suturing tutoring program and medical students attending ordinary medical school training program. Participants consisted of 2 groups of medical students who had never performed suturing. The study group had the role of suturing tutor to teach interested high school students. The control group consisted of volunteers from the ordinary medical school program. Skills measurement was performed by having students from both the groups perform 3 vertical mattress sutures on a model. The study group was tested at weeks 1, 9, and 10 to assess improvement. Both the groups were tested at week 10 to compare final learning outcome. There were 41 and 40 participants in the study group and the control group, respectively. ISS was significantly improved in the study group from week 1-week 10 (7.0 ± 1.3 vs. 8.2 ± 0.9, p = 0.01). At week 10, the study group had a higher mean ISS than the control group (8.2 ± 0.9 vs. 7.8 ± 1.1, p = 0.68). Mean suturing time and mean placement error were also lower in the study group at the end of suturing training (5:1 ± 1:0 vs. 5:2 ± 1:2, p = 0.13; 7.4 ± 7.4 vs. 8.0 ± 10.8, p = 0.44). Tutoring trainees to suture can improve a student's ability to learn how to suture. Copyright © 2016 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.
Nett, Michael; Avelar, Rui; Sheehan, Michael; Cushner, Fred
2011-03-01
Standard medial parapatellar arthrotomies of 10 cadaveric knees were closed with either conventional interrupted absorbable sutures (control group, mean of 19.4 sutures) or a single running knotless bidirectional barbed absorbable suture (experimental group). Water-tightness of the arthrotomy closure was compared by simulating a tense hemarthrosis and measuring arthrotomy leakage over 3 minutes. Mean total leakage was 356 mL and 89 mL in the control and experimental groups, respectively (p = 0.027). Using 8 of the 10 knees (4 closed with control sutures, 4 closed with an experimental suture), a tense hemarthrosis was again created, and iatrogenic suture rupture was performed: a proximal suture was cut at 1 minute; a distal suture was cut at 2 minutes. The impact of suture rupture was compared by measuring total arthrotomy leakage over 3 minutes. Mean total leakage was 601 mL and 174 mL in the control and experimental groups, respectively (p = 0.3). In summary, using a cadaveric model, arthrotomies closed with a single bidirectional barbed running suture were statistically significantly more water-tight than those closed using a standard interrupted technique. The sample size was insufficient to determine whether the two closure techniques differed in leakage volume after suture rupture.
Study of insertion force and deformation for suturing with precurved NiTi guidewire.
Wang, Yancheng; Chen, Roland K; Tai, Bruce L; Xu, Kai; Shih, Albert J
2015-04-01
This research presents an experimental study evaluating stomach suturing using a precurved nickel-titanium (NiTi) guidewire for an endoscopic minimally invasive obesity treatment. Precise path planning is critical for accurate and effective suturing. A position measurement system utilizing a hand-held magnetic sensor was used to measure the shape of a precurved guidewire and to determine the radius of curvature before and after suturing. Ex vivo stomach suturing experiments using four different guidewire tip designs varying the radius of curvature and bevel angles were conducted. The changes in radius of curvature and suturing force during suturing were measured. A model was developed to predict the guidewire radius of curvature based on the measured suturing force. Results show that a small bevel angle and a large radius of curvature reduce the suturing force and the combination of small bevel angle and small radius of curvature can maintain the shape of guidewire for accurate suturing.
Review of fixation techniques for the four-part fractured proximal humerus in hemiarthroplasty.
Baumgartner, Daniel; Nolan, Betsy M; Mathys, Robert; Lorenzetti, Silvio Rene; Stüssi, Edgar
2011-07-18
The clinical outcome of hemiarthroplasty for proximal humeral fractures is not satisfactory. Secondary fragment dislocation may prevent bone integration; the primary stability by a fixation technique is therefore needed to accomplish tuberosity healing. Present technical comparison of surgical fixation techniques reveals the state-of-the-art approach and highlights promising techniques for enhanced stability. A classification of available fixation techniques for three- and four part fractures was done. The placement of sutures and cables was described on the basis of anatomical landmarks such as the rotator cuff tendon insertions, the bicipital groove and the surgical neck. Groups with similar properties were categorized. Materials used for fragment fixation include heavy braided sutures and/or metallic cables, which are passed through drilling holes in the bone fragments. The classification resulted in four distinct groups: A: both tuberosities and shaft are fixed together by one suture, B: single tuberosities are independently connected to the shaft and among each other, C: metallic cables are used in addition to the sutures and D: the fragments are connected by short stitches, close to the fragment borderlines. A plurality of techniques for the reconstruction of a fractured proximal humerus is found. The categorisation into similar strategies provides a broad overview of present techniques and supports a further development of optimized techniques. Prospective studies are necessary to correlate the technique with the clinical outcome.
Review of fixation techniques for the four-part fractured proximal humerus in hemiarthroplasty
2011-01-01
Introduction The clinical outcome of hemiarthroplasty for proximal humeral fractures is not satisfactory. Secondary fragment dislocation may prevent bone integration; the primary stability by a fixation technique is therefore needed to accomplish tuberosity healing. Present technical comparison of surgical fixation techniques reveals the state-of-the-art approach and highlights promising techniques for enhanced stability. Method A classification of available fixation techniques for three- and four part fractures was done. The placement of sutures and cables was described on the basis of anatomical landmarks such as the rotator cuff tendon insertions, the bicipital groove and the surgical neck. Groups with similar properties were categorized. Results Materials used for fragment fixation include heavy braided sutures and/or metallic cables, which are passed through drilling holes in the bone fragments. The classification resulted in four distinct groups: A: both tuberosities and shaft are fixed together by one suture, B: single tuberosities are independently connected to the shaft and among each other, C: metallic cables are used in addition to the sutures and D: the fragments are connected by short stitches, close to the fragment borderlines. Conclusions A plurality of techniques for the reconstruction of a fractured proximal humerus is found. The categorisation into similar strategies provides a broad overview of present techniques and supports a further development of optimized techniques. Prospective studies are necessary to correlate the technique with the clinical outcome. PMID:21762540
Faria, Raquel Lourdes; Cardoso, Lincoln Marcelo Lourenço; Akisue, Gokithi; Pereira, Cristiane Aparecida; Junqueira, Juliana Campos; Jorge, Antonio Olavo Cardoso; Santos Júnior, Paulo Villela
2011-10-01
The objective of this study was to compare the antimicrobial effect of mouthwashes containing Calendula officinalis L., Camellia sinensis (L.) Kuntze and 0.12% chlorhexidine digluconate on the adherence of microorganisms to suture materials after extraction of unerupted third molars. Eighteen patients with unerupted maxillary third molars indicated for extraction were selected (n=6 per mouthwash). First, the patients were subjected to extraction of the left tooth and instructed not to use any type of antiseptic solution at the site of surgery (control group). After 15 days, the right tooth was extracted and the patients were instructed to use the Calendula officinalis, Camellia sinensis or chlorhexidine mouthwash during 1 week (experimental group). For each surgery, the sutures were removed on postoperative day 7 and placed in sterile phosphate-buffered saline. Next, serial dilutions were prepared and seeded onto different culture media for the growth of the following microorganisms: blood agar for total microorganism growth; Mitis Salivarius bacitracin sucrose agar for mutans group streptococci; mannitol agar for Staphylococcus spp.; MacConkey agar for enterobacteria and Pseudomonas spp., and Sabouraud dextrose agar containing chloramphenicol for Candida spp. The plates were incubated during 24-48 h at 37ºC for microorganism count (CFU/mL). The three mouthwashes tested reduced the number of microorganisms adhered to the sutures compared to the control group. However, significant differences between the control and experimental groups were only observed for the mouthwash containing 0.12% chlorhexidine digluconate. Calendula officinalis L. and Camellia sinensis (L.) Kuntze presented antimicrobial activity against the adherence of microorganisms to sutures but were not as efficient as chlorhexidine digluconate.
Phair, Kristen A; Sutherland-Smith, Meg; Pye, Geoffrey W; Pessier, Allan P; Clippinger, Tracy L
2014-06-01
A 42-year-old female Indian elephant (Elephas maximus indicus) developed a sudden onset of excessive salivation and dysphagia. Esophageal obstruction was suspected; possibly related to palm frond ingestion. Esophageal endoscopy revealed a mat of plant material in the distal esophagus. An initial attempt at relieving the obstruction was unsuccessful, but subsequent use of custom-made instruments along with insufflation and hydropulsion enabled partial removal of the material. Postimmobilization care included aggressive intravenous and rectal fluids, anti-inflammatory and antibiotic administration, and fasting. Despite treatment, the dysphagia persisted and the elephant was euthanized due to lack of improvement and grave prognosis. Postmortem examination revealed remaining plant material in the esophagus, complicated by an esophageal dissection, mural hematoma, and secondary bacterial infection. Iatrogenic trauma may have contributed to the extent of esophageal injury. Although treatment was ultimately unsuccessful, the supportive care employed could potentially aid recovery in cases of less severe esophageal trauma.
Takeuchi, Masaki
2013-01-01
Background: This study describes the use of a bioabsorbable suture for skin suturing during surgery for lateral ray polydactyly followed by favorable postoperative outcome without the need for postoperative suture removal. Methods: A 5-0 Vicryl Rapide suture was used for skin suturing during surgery for lateral ray polydactyly in 9 children (mean age, 12.4 mo). Children were allowed to walk and bathe 2 weeks after surgery when over-the-suture taping therapy was started. Results: In all cases, the Vicryl Rapide suture disappeared completely within 3 weeks of surgery, and no removal of residual suture was required. No postoperative complications, such as suture abscess, wound dehiscence, or ulcer, were observed. During a mean 24-month postoperative follow-up, no elevation of the interdigital space due to hypertrophic scarring or scar contracture was observed, and no revision surgery was required. Conclusions: Although the breaking strength of Vicryl Rapide declines within the first 10 days after surgery, this property will unlikely lead to postoperative wound dehiscence due to a relatively light load being applied to the lateral toes. The use of a bioabsorbable suture for skin suturing during surgery for lateral lay polydactyly is highly beneficial as it eliminates pain caused by suture removal and the risk of tissue damage while reducing the burden on medical staff. PMID:25289236
Kohlmaier, Benno; Trobisch, Andreas; Pfurtscheller, Klaus; Knez, Igor; Klepetko, Walter; Pilhatsch, Alexander; Schweintzger, Sabrina; Zenz, Werner
2018-04-09
We describe herein the management of a 16-year-old girl with cystic echinococcosis (CE) of the right ventricle and massive obstruction of the pulmonary vessel system by parasitic metastatic dissemination. After resection of the cardiac cyst, pulmonary thromboendarterectomy was performed to remove parts of the obstructive parasitic material. The treatment reduced the elevated pulmonary arterial pressure, improving the patient's overall condition.
Song, Dongzhe; Zhang, Fugui; Reid, Russell R; Ye, Jixing; Wei, Qiang; Liao, Junyi; Zou, Yulong; Fan, Jiaming; Ma, Chao; Hu, Xue; Qu, Xiangyang; Chen, Liqun; Li, Li; Yu, Yichun; Yu, Xinyi; Zhang, Zhicai; Zhao, Chen; Zeng, Zongyue; Zhang, Ruyi; Yan, Shujuan; Wu, Tingting; Wu, Xingye; Shu, Yi; Lei, Jiayan; Li, Yasha; Zhang, Wenwen; Wang, Jia; Lee, Michael J; Wolf, Jennifer Moriatis; Huang, Dingming; He, Tong-Chuan
2017-11-01
The cranial suture complex is a heterogeneous tissue consisting of osteogenic progenitor cells and mesenchymal stem cells (MSCs) from bone marrow and suture mesenchyme. The fusion of cranial sutures is a highly coordinated and tightly regulated process during development. Craniosynostosis is a congenital malformation caused by premature fusion of cranial sutures. While the progenitor cells derived from the cranial suture complex should prove valuable for studying the molecular mechanisms underlying suture development and pathogenic premature suture fusion, primary human cranial suture progenitors (SuPs) have limited life span and gradually lose osteoblastic ability over passages. To overcome technical challenges in maintaining sufficient and long-term culture of SuPs for suture biology studies, we establish and characterize the reversibly immortalized human cranial suture progenitors (iSuPs). Using a reversible immortalization system expressing SV40 T flanked with FRT sites, we demonstrate that primary human suture progenitor cells derived from the patent sutures of craniosynostosis patients can be efficiently immortalized. The iSuPs maintain long-term proliferative activity, express most of the consensus MSC markers and can differentiate into osteogenic and adipogenic lineages upon BMP9 stimulation in vitro and in vivo. The removal of SV40 T antigen by FLP recombinase results in a decrease in cell proliferation and an increase in the endogenous osteogenic and adipogenic capability in the iSuPs. Therefore, the iSuPs should be a valuable resource to study suture development, intramembranous ossification and the pathogenesis of craniosynostosis, as well as to explore cranial bone tissue engineering. © 2017 The Authors. Journal of Cellular and Molecular Medicine published by John Wiley & Sons Ltd and Foundation for Cellular and Molecular Medicine.
The modified Altemeier procedure for a loop colostomy prolapse.
Watanabe, Makoto; Murakami, Masahiko; Ozawa, Yoshiaki; Uchida, Marie; Yamazaki, Kimiyasu; Fujimori, Akira; Otsuka, Koji; Aoki, Takeshi
2015-11-01
Loop colostomy prolapse is associated with an impaired quality of life. Surgical treatment may sometimes be required for cases that cannot be closed by colon colostomy because of high-risk morbidities or advanced disease. We applied the Altimeter operation for patients with transverse loop colostomy. The Altemeier operation is therefore indicated for rectal prolapse. This technique involves a simple operation, which includes a circumferential incision through the full thickness of the outer and inner cylinder of the prolapsed limb, without incising the abdominal wall, and anastomosis with sutures using absorbable thread. We performed the Altemeier operation for three cases of loop stomal prolapse. Those patients demonstrated no postoperative complications (including obstruction, prolapse recurrence, or hernia). Our findings suggest that this procedure is useful as an optional surgical treatment for cases of transverse loop colostomy prolapse as a permanent measure in patients with high-risk morbidities or advanced disease.
The continuing challenge of parastomal hernia: failure of a novel polypropylene mesh repair.
Morris-Stiff, G.; Hughes, L. E.
1998-01-01
In an attempt to reduce the high recurrence rate after repair of parastomal hernia, a technique was devised in which non-absorbable mesh was used to provide a permanent closure of the gap between the emerging bowel and abdominal wall. Seven patients were treated during the period 1990-1992. Five-year follow-up has given disappointing results, with recurrent hernia in 29% of cases and serious complications, including obstruction and dense adhesions to the intra-abdominal mesh, in 57% and a mesh-related abscess in 15% of cases. This study highlights a dual problem--failure of a carefully sutured mesh to maintain an occlusive position, and complications of the mesh itself. The poor results obtained with this technique together with the disappointing results with other methods described in the literature confirms that parastomal hernia presents a continuing challenge. Images Figure 1 Figure 2 PMID:9682640
Du, Dongxing; Jiang, Song; Wang, Ze; Hu, Yingying; He, Zhaoming
2014-01-01
Mitral valve (MV) edge-to-edge repair (ETER) is a surgical procedure for the correction of mitral valve regurgitation by suturing the free edge of the leaflets. The leaflets are often sutured at three different positions: central, lateral and commissural portions. To study the effects of position of suture on left ventricular (LV) fluid mechanics under mitral valve ETER, a parametric model of MV-LV system during diastole was developed. The distribution and development of vortex and atrio-ventricular pressure under different suture position were investigated. Results show that the MV sutured at central and lateral in ETER creates two vortex rings around two jets, compared with single vortex ring around one jet of the MV sutured at commissure. Smaller total orifices lead to a higher pressure difference across the atrio-ventricular leaflets in diastole. The central suture generates smaller wall shear stresses than the lateral suture, while the commissural suture generated the minimum wall shear stresses in ETER.
Zorn, Kevin C; Trinh, Quoc-Dien; Jeldres, Claudio; Schmitges, Jan; Widmer, Hugues; Lattouf, Jean-Baptiste; Sammon, Jesse; Liberman, Dan; Sun, Maxine; Bianchi, Marco; Karakiewicz, Pierre I; Denis, Ronald; Gautam, Gagan; El-Hakim, Assaad
2012-05-01
Study Type - RCT (randomized trial) Level of Evidence 2b. What's known on the subject? and What does the study add? In a previous randomized controlled trial, barbed polyglyconate suture for vesico-urethral anastomosis was associated with more frequent cystogram leaks, longer mean catheterization times and greater suture costs per case. In the current randomized controlled trial, we show that barbed polyglyconate suture is associated with decreased anastomosis time, decreased need to readjust suture tension, cost reduction, and equal continence and early/late urinary complication rates. To examine the effectiveness of barbed polyglyconate suture (V-Loc 180; Covidien, Mansfield, MA, USA) compared with standard monofilament for posterior reconstruction (PR) and vesico-urethral anastomosis (VUA) during robot-assisted radical prostatectomy (RARP). A prospective randomized controlled trial was conducted in 70 consecutive RARP cases by a single surgeon (K.C.Z.). Standard VUA was performed using three 4-0 poliglecaprone 25 (Monocryl; Ethicon Endosurgery, Cincinnati, OH, USA) sutures secured with absorbable suture clips (LapraTy, Ethicon; one single 6-inch [15.2 cm] for PR and two attached 6-inch [15.2 cm] for VUA). Barbed suture VUA was performed using two 3-0 6-inch (15.2 cm) barbed polyglyconate sutures. Time to complete the suture set-up by the nursing team, anastomosis time and need to adjust suture tension were recorded. Suture-related complications, validated-questionnaire continence and cost were also examined. Compared with a conventional reconstruction technique, there was a significant reduction in mean nurse set-up time (31 vs. 294 s; P < 0.01) and reconstruction time (13.1 vs. 20.8 min; P < 0.01) for the barbed suture technique. Need to readjust suture tension or to place additional suture clips for watertight closure was greater in the standard monofilament group than in the barbed suture group (6% vs. 24%; P= 0.03). • A cost reduction was recorded at our institution (48.05 vs. 70.25 $CAN) with the barbed suture technique. • With a mean follow-up of 6.2 months, no delayed anastomotic leak or bladder neck contracture was observed in either group. • Pad-free continence outcomes for the monofilament suture vs the barbed suture groups at 1 (64 vs. 69%, P= 0.6), 3 (76 vs. 81%, P= 0.5) and 6 months (88 vs. 92%, P= 0.7) were similar. • Compared with standard monofilament suture, the unidirectional barbed polyglyconate suture appears to provide safe, efficient and cost-effective PR and VUA during RARP. • Use of the interlocked barbed polyglyconate suture technique prevents slippage, precluding the need for assistance, knot-tying and constant reassessment of anastomosis integrity. © 2012 THE AUTHORS. BJU INTERNATIONAL © 2012 BJU INTERNATIONAL.
Analysis of suture anchor eyelet position on suture failure load.
Aktay, Sevima A; Kowaleski, Michael P
2011-06-01
To compare mechanical performance of 2 orientations of the 5 mm Corkscrew® suture anchor with #5 Fiberwire® . In vitro biomechanical study. Suture anchor-suture constructs (n=40). Acute and cyclic tensile loads were applied to suture threaded through eyelets of 40 anchors perpendicular to the long axis of the anchor. Eyelets were positioned so that the suture pull was in line with (anchor rotation angle of 0° [ARA 0]) or 90° (ARA 90) to the eyelet plane. Load at failure, stiffness, and cycles to failure were determined. All constructs failed by suture breakage at the eyelet. Mean load at failure was significantly higher in the ARA 90 group (634 ± 93 N) compared with the ARA 0 group (495 ± 52 N; P=.0015). No significant difference was found between groups for mean number of cycles to failure (270 ± 177 versus 178 ± 109; P=.2166) and stiffness (50 ± 4 versus 48 ± 5 N/mm; P=.3141). The Corkscrew® 5 mm suture anchor with Fiberwire® suture fails via suture breakage at the eyelet under higher acute loads if the suture is loaded at an angle of 90° compared with 0° with respect to the plane of the eyelet. © Copyright 2011 by The American College of Veterinary Surgeons.
Perez-Blanca, Ana; Prado Nóvoa, María; Lombardo Torre, Maximiano; Espejo-Reina, Alejandro; Ezquerro Juanco, Francisco; Espejo-Baena, Alejandro
2018-04-01
To assess the role of suture cutout in the mechanics of failure of the repaired posterior meniscal root during the early post-operative period when using sutures of different shape. Twenty medial porcine menisci were randomized in two groups depending on the suture shape used to repair the posterior root: thread or tape. The sutured menisci were subjected to cyclic loading (1000 cycles, (10, 30) N) followed by load-to-failure testing. Residual displacements, stiffness, and ultimate failure load were determined. During tests, the tissue-suture interface was recorded using a high-resolution camera. In cyclic tests, cutout progression at the suture insertion points was not observed for any specimen of either group and no differences in residual displacements were found between use of thread or tape. In load-to-failure tests, suture cutout started in all menisci at a load close to the ultimate failure and all specimens failed by suture pullout. Suture tape had a greater ultimate load with no other differences. In a porcine model of a repaired posterior meniscal root subjected to cyclic loads representative of current rehabilitation protocols in the early post-operative period under restricted loading conditions, suture cutout was not found as a main source of permanent root displacement when using suture thread or tape. Suture cutout progression started at high loading levels close to the ultimate load of the construct. Tape, with a meniscus-suture contact area larger than thread, produced higher ultimate load.
Cranial suture biology of the Aleutian Island inhabitants.
Cray, James; Mooney, Mark P; Siegel, Michael I
2011-04-01
Research on cranial suture biology suggests there is biological and taxonomic information to be garnered from the heritable pattern of suture synostosis. Suture synostosis along with brain growth patterns, diet, and biomechanical forces influence phenotypic variability in cranial vault morphology. This study was designed to determine the pattern of ectocranial suture synostosis in skeletal populations from the Aleutian Islands. We address the hypothesis that ectocranial suture synostosis pattern will differ according to cranial vault shape. Ales Hrdlicka identified two phenotypes in remains excavated from the Aleutian Island. The Paleo-Aleutians, exhibiting a dolichocranic phenotype with little prognathism linked to artifacts distinguished from later inhabitants, Aleutians, who exhibited a brachycranic phenotype with a greater amount of prognathism. A total of 212 crania representing Paleo-Aleuts and Aleutian as defined by Hrdlicka were investigated for suture synostosis pattern following standard methodologies. Comparisons were performed using Guttmann analyses. Results revealed similar suture fusion patterns for the Paleo-Aleut and Aleutian, a strong anterior to posterior pattern of suture fusion for the lateral-anterior suture sites, and a pattern of early termination at the sagittal suture sites for the vault. These patterns were found to differ from that reported in the literature. Because these two populations with distinct cranial shapes exhibit similar patterns of suture synostosis it appears pattern is independent of cranial shape in these populations of Homo sapiens. These findings suggest that suture fusion patterns may be population dependent and that a standardized methodology, using suture fusion to determine age-at-death, may not be applicable to all populations. Copyright © 2011 Wiley-Liss, Inc.
Surgical management of peptic ulcer disease today--indication, technique and outcome.
Zittel, T T; Jehle, E C; Becker, H D
2000-03-01
The current surgical management of peptic ulcer disease and its outcome have been reviewed. Today, surgery for peptic ulcer disease is largely restricted to the treatment of complications. In peptic ulcer perforation, a conservative treatment trial can be given in selected cases. If laparotomy is necessary, simple closure is sufficient in the large majority of cases, and definitive ulcer surgery to reduce gastric acid secretion is no longer justified in these patients. Laparoscopic surgery for perforated peptic ulcer has failed to prove to be a significant advantage over open surgery. In bleeding peptic ulcers, definitive hemostasis can be achieved by endoscopic treatment in more than 90% of cases. In 1-2% of cases, immediate emergency surgery is necessary. Some ulcers have a high risk of re-bleeding, and early elective surgery might be advisable. Surgical bleeding control can be achieved by direct suture and extraluminal ligation of the gastroduodenal artery or by gastric resection. Benign gastric outlet obstruction can be controlled by endoscopic balloon dilatation in 70% of cases, but gastrojejunostomy or gastric resection are necessary in about 30% of cases. Elective surgery for peptic ulcer disease has been largely abandoned, and bleeding or obstructing ulcers can be managed safely by endoscopic treatment in most cases. However, surgeons will continue to encounter patients with peptic ulcer disease for emergency surgery. Currently, laparoscopic surgery has no proven advantage in peptic ulcer surgery.
Younesi, Mousa; Knapik, Derrick M; Cumsky, Jameson; Donmez, Baris Ozgur; He, Ping; Islam, Anowarul; Learn, Greg; McClellan, Philip; Bohl, Michael; Gillespie, Robert J; Akkus, Ozan
2017-11-01
Flexor tendon lacerations are traditionally repaired by using non-absorbable monofilament sutures. Recent investigations have explored to improve the healing process by growth factor delivery from the sutures. However, it is difficult to conjugate growth factors to nylon or other synthetic sutures. This study explores the performance of a novel electrochemically aligned collagen suture in a flexor tendon repair model with and without platelet derived growth factor following complete tendon laceration in vivo. Collagen suture was fabricated via electrochemical alignment process. Heparin was covalently bound to electrochemically aligned collagen sutures (ELAS) to facilitate affinity bound delivery of platelet-derived growth factor-BB (PDGF-BB). Complete laceration of the flexor digitorum profundus in the third digit of the foot was performed in 36 skeletally mature White Leghorn chickens. The left foot was used as the positive control. Animals were randomly divided into three groups: control specimens treated with standard nylon suture (n=12), specimens repaired with heparinated ELAS suture without PDGF-BB (n=12) and specimens repaired with heparinated ELAS suture with affinity bound PDGF-BB (n=12). Specimens were harvested at either 4weeks or 12weeks following tendon repair. Differences between groups were evaluated by the degree of gross tendon excursion, failure load/stress, stiffness/modulus, absorbed energy at failure, elongation/strain at failure. Quantitative histological scoring was performed to assess cellularity and vascularity. Closed flexion angle measurements demonstrated no significant differences in tendon excursion between the study groups at 4 or 12weeks. Biomechanical testing showed that the group treated with PDGF-BB bound heparinated ELAS suture had significantly higher stiffness and failure load (p<0.05) at 12-weeks relative to both heparinated ELAS suture and nylon suture. Similarly, the group treated with PDGF-BB bound suture had significantly higher ultimate tensile strength and Young's modulus (p<0.05) at 12-weeks relative to both ELAS suture and nylon suture. Compared to nylon controls, heparinized ELAS with PDGF-BB improved biomechanics and vascularity during tendon healing by 12-weeks following primary repair. The ability of ELAS to deliver PDGF-BB to the lacerated area of tendon presents investigators with a functional bioinductive platform to improve repair outcomes following flexor tendon repair. A high strength aligned collagen suture was fabricated via linear electrocompaction and heparinized for prolonged delivery of PDFG-BB. When it was used to suture a complete lacerated flexor tendon in a chicken model controlled release of the PDGF-BB improved the strength of treated tendon after 12 weeks compared to tendon sutured with commercial nylon suture. Furthermore, Collagen suture with affinity bound PDGF-BB enhanced the vascularization and remodeling of lacerated tendon when it compare to synthetic nylon suture. Overall, electrocompacted collagen sutures holds potential to improve repair outcome in flexor tendon surgeries by improving repair strength and stiffness, vascularity, and remodeling via sustained delivery of the PDGF-BB. The bioinductive collagen suture introduces a platform for sustained delivery of other growth factors for a wide-array of applications. Copyright © 2017 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
[Manual suture versus/or mechanical suture from the Austrian viewpoint].
Kronberger, L; Germann, R
1987-01-01
A general inquiry was made at surgical units and university clinics in Austria about the anastomosis techniques used between 1980 to 1985. The result was that in 90.3% the suture was made by hand and in 9.7% by machine. The first mentioned was performed as double row inverting suture by 66% of our surgeons, and only in 30% as an all-layer suture. The stapler-technique was mostly preferred for the oesophago-jejunostomy and the high and lower resection of the rectum. A leakage of the suture line was observed in 3.9% after sewing by hand and in 6.3% after stapling. The total lethality finally was 1.4% for hand made suture and 1.8% for apparative suture.
Suture slippage in knotless suture anchors resulting in subacromial-subdeltoid bursitis.
Hayeri, Mohammad Reza; Keefe, Daniel T; Chang, Eric Y
2016-05-01
Rotator cuff repair using a suture bridge and knotless suture anchors is a relatively new, but increasingly used technique. The suture bridge technique creates an anatomically similar and more secure rotator cuff repair compared with conventional arthroscopic techniques and the use of knotless anchors eliminates the challenges associated with knot tying during arthroscopic surgery. However, previous in vitro biomechanical tests have shown that the hold of the suture in a knotless suture anchor is far lower than the pullout strength of the anchor from bone. Up until now slippage has been a theoretical concern. We present a prospectively diagnosed case of in vivo suture loosening after rotator cuff repair using a knotless bridge technique resulting in subacromial-subdeltoid bursitis.
46 CFR 153.931 - Obstruction of pumproom ladderways.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 5 2014-10-01 2014-10-01 false Obstruction of pumproom ladderways. 153.931 Section 153.931 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CERTAIN BULK DANGEROUS CARGOES SHIPS CARRYING BULK LIQUID, LIQUEFIED GAS, OR COMPRESSED GAS HAZARDOUS MATERIALS Operations General...
46 CFR 153.931 - Obstruction of pumproom ladderways.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 5 2011-10-01 2011-10-01 false Obstruction of pumproom ladderways. 153.931 Section 153.931 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CERTAIN BULK DANGEROUS CARGOES SHIPS CARRYING BULK LIQUID, LIQUEFIED GAS, OR COMPRESSED GAS HAZARDOUS MATERIALS Operations General...
46 CFR 153.931 - Obstruction of pumproom ladderways.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 5 2010-10-01 2010-10-01 false Obstruction of pumproom ladderways. 153.931 Section 153.931 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CERTAIN BULK DANGEROUS CARGOES SHIPS CARRYING BULK LIQUID, LIQUEFIED GAS, OR COMPRESSED GAS HAZARDOUS MATERIALS Operations General...
46 CFR 153.931 - Obstruction of pumproom ladderways.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 5 2012-10-01 2012-10-01 false Obstruction of pumproom ladderways. 153.931 Section 153.931 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CERTAIN BULK DANGEROUS CARGOES SHIPS CARRYING BULK LIQUID, LIQUEFIED GAS, OR COMPRESSED GAS HAZARDOUS MATERIALS Operations General...
46 CFR 153.931 - Obstruction of pumproom ladderways.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 5 2013-10-01 2013-10-01 false Obstruction of pumproom ladderways. 153.931 Section 153.931 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CERTAIN BULK DANGEROUS CARGOES SHIPS CARRYING BULK LIQUID, LIQUEFIED GAS, OR COMPRESSED GAS HAZARDOUS MATERIALS Operations General...
[Stapler and manual bronchial anastomosis--results of a consecutive trial series].
Junginger, T; Walgenbach, S; Pichlmaier, H
1989-01-01
After lobectomy and pneumonectomy in experimental evaluations stapled bronchial closures showed the lowest incidence of inflammatory reaction and the highest strength determined by leakage pressure compared with other suture material. A total of 233 lung resections-performed at Surgical University Clinic Köln-Lindenthal and the Clinic for General and Abdominal Surgery of the Johannes-Gutenberg-Universität Mainz--were reviewed. Mechanical stapling reduced the rate of bronchopleural fistulas to 2.0% compared with 7.1% after manual suturing. In parallel, mortality related to bronchial stump leakage decreased to 0.7%. Main advantages of bronchial closure with staplers are the simplicity of their use, the speed and the uniformity of the closure. Thereby stapling devices are valuable completions in pulmonary surgery.
Fishtail on a line technique for capsular tension ring insertion.
Rixen, Jordan J; Oetting, Thomas A
2014-07-01
We describe a capsular tension ring (CTR) insertion technique that is a modification of the previously described fishtail technique. A suture line is used to pull the leading eyelet out through the main incision to form the fish configuration. Similar to the fishtail technique, this insertion technique minimizes the risk for zonular damage or a capsule tear because the CTR is not dialed into the capsular bag. The advantage of the suture line is that it prevents over bending of the CTR during insertion through the main incision, which can occur using the traditional fishtail technique. Neither author has a financial or proprietary interest in any material or method mentioned. Copyright © 2014 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Multifunctional silk-heparin biomaterials for vascular tissue engineering applications
Seib, F. Philipp; Herklotz, Manuela; Burke, Kelly A.; Maitz, Manfred F.; Werner, Carsten; Kaplan, David L.
2013-01-01
Over the past 30 years, silk has been proposed for numerous biomedical applications that go beyond its traditional use as a suture material. Silk sutures are well tolerated in humans, but the use of silk for vascular engineering applications still requires extensive biocompatibility testing. Some studies have indicated a need to modify silk to yield a hemocompatible surface. This study examined the potential of low molecular weight heparin as a material for refining silk properties by acting as a carrier for vascular endothelial growth factor (VEGF) and improving silk hemocompatibility. Heparinized silk showed a controlled VEGF release over 6 days; the released VEGF was bioactive and supported the growth of human endothelial cells. Silk samples were then assessed using a humanized hemocompatibility system that employs whole blood and endothelial cells. The overall thrombogenic response for silk was very low and similar to the clinical reference material polytetrafluoroethylene. Despite an initial inflammatory response to silk, apparent as complement and leukocyte activation, the endothelium was maintained in a resting, anticoagulant state. The low thrombogenic response and the ability to control VEGF release support the further development of silk for vascular applications. PMID:24099708
Spring, Michelle A
2018-04-07
Fluid accumulation is a common complication after abdominoplasty procedures, and is typically managed by the placement of post-surgical drains. Progressive tension sutures (PTS) have been shown to be an effective approach to reduce the dead space by point-wise mechanical fixation, allowing for drain-free procedures. Lysine-derived urethane surgical adhesive provides an alternative approach for mechanical fixation and reduction of dead space, and may reduce surgery time compared to PTS. This prospective, controlled, single center clinical study compared progressive tension suture wound closure technique without drains (control) to tissue adhesive wound closure technique without drains (test) during abdominoplasty surgery. The objective was to determine if lysine-derived urethane surgical adhesive is an effective alternative to PTS for drain-free abdominoplasty procedures. Patients undergoing abdominoplasty who met the established inclusion/exclusion criteria were consented and enrolled in the study. Ten PTS (control) cases were performed, followed immediately by ten tissue adhesive (test) cases. Drains were not used in any procedures. Key outcome measures included all major and minor post-surgical complications requiring any intervention, the time to place progressive tension sutures versus time for tissue adhesive application, and number of PTS attachments versus number of adhesive drops applied. Surgeries were completed over an 8-month period. No statistical differences were identified between the two groups with regard to age, BMI, dissection surface area or flap weight. No clinical seroma formation was observed in either group. In the control (PTS) group, two patients developed small areas of dermal closure suture abscess requiring removal of suture material. One control patient developed drainage and fat necrosis thought to be related to PTS above the incision and later required a scar revision. One tissue adhesive patient developed hypertrophic scars of both her breast reduction and abdominoplasty scars requiring additional treatment. The average time to place PTS in the control group was 10.7 minutes (range, 7-18 minutes) and the average number of sutures placed was 16.6 (range, 12-22 sutures). In the test group, the average time to place the tissue adhesive and hold pressure was 5.9 minutes (range 5.5-8.0 minutes). The average number of tissue adhesive drops applied was 69.6 (range: 63-78 drops). In the tissue adhesive group, both the reduction in time for flap adhesion and the increased number of adhesive points were statistically significant when compared to PTS. Lysine-derived urethane surgical adhesive was applied in less time than progressive tension sutures, even after accounting for holding pressure for 5 minutes. The tissue adhesive provided four times the number of attachment points compared to PTS, although the significance of this is not clear. There were no postoperative clinical seromas detected in either group and there were no major complications in either group. Based on these results, the use of lysine-derived urethane surgical adhesive was found to be a safe and effective alternative to progressive tension sutures to reduce seroma formation in drain-free abdominoplasty procedures.
de Carvalho, Marcus Vinicius H.; Marchi, Evaldo; Lourenço, Edmir Américo
2017-01-01
Introduction Tissue adhesives can be used as adjacent to sutures to drop or avoid bleeding in cardiovascular operations. Objective To verify the efficiency of fibrin and cyanoacrylate adhesive to seal arterial sutures and if the adhesives penetrate through suture line to the inner of arteries. Methods 20 abdominal aorta segments of pigs were divided into two groups according to the adhesive which would be used as adjacent to the suture. In every arterial segment an arteriotomy was done, followed by a conventional artery closure. Afterwards a colloidal fluid was injected inside the arterial segment with a simultaneous intravascular pressure monitoring up to a fluid leakage through the suture. This procedure was repeated after application of one of the adhesives on the suture in order to check if the bursting pressure increases. The inner aorta segments also were analyzed in order to check if there was intraluminal adhesive penetration. Results In Suture 1 group, the mean arterial pressure sustained by the arterial suture reached 86±5.35 mmHg and after the fibrin adhesive application reached 104±11.96 (P<0.002). In the Suture 2 group, the mean arterial pressure sustained by the suture reached 83±2.67 mmHg and after the cyanoacrylate adhesive application reached 152±14.58 mmHg (P<0.002). Intraluminal adhesive penetration has not been noticed. Conclusion There was a significant rise in the bursting pressure when tissue adhesives were used as adjacent to arterial suture, and this rise was higher if the cyanoacrylate adhesive was used. In addition, the adhesives do not penetrate through the suture line into the arteries. PMID:29267611
Cray, James; Cooper, Gregory M; Mooney, Mark P; Siegel, Michael I
2011-01-01
Research has shown that Pan and Homo have similar ectocranial suture synostosis patterns and a similar suture ontogeny (relative timing of suture fusion during the species ontogeny). This ontogeny includes patency during and after neurocranial expansion with a delayed bony response associated with adaptation to biomechanical forces generated by mastication. Here we investigate these relationships for Gorilla by examining the association among ectocranial suture morphology, cranial volume (as a proxy for neurocranial expansion) and dental development (as a proxy for the length of time that it has been masticating hard foods and exerting such strains on the cranial vault) in a large sample of Gorilla gorilla skulls. Two-hundred and fifty-five Gorilla gorilla skulls were examined for ectocranial suture closure status, cranial volume and dental eruption. Regression models were calculated for cranial volumes by suture activity, and Kendall's tau (a non-parametric measure of association) was calculated for dental eruption status by suture activity. Results suggest that, as reported for Pan and Homo, neurocranial expansion precedes suture synostosis activity. Here, Gorilla was shown to have a strong relationship between dental development and suture activity (synostosis). These data are suggestive of suture fusion extending further into ontogeny than brain expansion, similar to Homo and Pan. This finding allows for the possibility that masticatory forces influence ectocranial suture morphology. PMID:21385182
Betz, C; Schleicher, P; Winkel, R; Hoffmann, R
2013-02-01
In this study we examined the tensile strength of core sutures of tendons. In particular, we examined the effect of having 2 or 4 stitch strands in the core suture as well as the effect of additional locking sutures on the tensile strength. 60 flexor tendons from the forepaws of freshly slaughtered swines were harvested for biomechanical testing. They were divided into 4 groups (A, B, C and D) of 15 sutures each. Group A: core suture after Zechner with 2 strands; group B: modified core suture with 4 strands; group C: modified core suture with 2 strands and 4 locking sutures; group D: modified core suture with 4 strands and 4 locking sutures. The primary tensile strength of the sutures was measured in Newton using the testing machine with a traction speed of 0.1 mm/s. Simultaneously, the increasing space forming at the suture was filmed against graph paper. Our command variables were force measured in Newton when forming a space of 2 mm as well as the force at which the suture failed. Statistical analysis was carried out with the software SPSS to produce a multivariate analysis with a statistical significance of p<0.05. Results are presented as averages including the 1st and 3rd quartile (1Q/3Q). Under traction to form a 2 mm space, the force measured with group A was 14.2 N (12.9/15.1 N). In group B the force 22.5 N (20.0/24.7 N) was significantly higher (p<0.05). Group C required a traction force of 28.7 N (23.5/35.8 N) which was significantly higher than for groups A and B. Group D required the significantly highest traction force of 42.0 N (39.5/46.0 N) to produce a 2 mm space. The force required for the suture to fail in group A was 19.9 N (17.9/22.8 N), in group B: 26.2 N (24.5/29.7 N), in group C 32.0 N (27.1/40.1 N) and in Group D 46.5 N (41.5/50.0 N); the differences between the gloups were all statistically significant. The primary tensile strength of core sutures after Zechner on flexor tendons from the forepaws of swines was significantly increased by doubling the number of sutures and also by use of 4 additional locking sutures. © Georg Thieme Verlag KG Stuttgart · New York.
[Retroperitoneoscopic assisted pyeloplasty for ureteropelvic junction obstruction in children].
Luque Mialdea, R; Martin-Crespo Izquierdo, R; Díaz Gómez, L; Moreno, L; Carrero, C; Cebrian, J
2007-04-01
Description of the retroperitoneoscopic approach in the conventional pyeloplasty for ureteropelvic junction obstruction in children. From 1998 pyeloplasty assisted by retroperitoneoscopic approach (PARA) was performed in 30 patients. Position in latero-dorsal decubitus and incision of 1 cm in angle costolumbar. We made retroperitoneoscopic space by ball dissection technique and 11 mm Hg pressure. The ureteropelvic junction was extracted through the incision of the port. The UPJ was resected in all patients and Anderson-Hynes pyeloplasty with double PDS 6/0 continuous sutures was performed. In all patients a drainage type Penrose in perirenal space was used. In the last 18 patients a 4F double-J stent was placed. The mean follow-up time was 42 months (range between 6 and 84 months). Operative time, hospital stay, handling of postoperative pain and the postoperative studies have been revised. In all the cases the retroperitoneoscopic approach was good for the identification and dissection of the ureteropelvic junction facilitating the extraction and reconstruction (pyeloplasty) through the mini-incision of the entrance port. The mean operative time was 90 min. (range between 65 and 128 min). We highlight the absence of intraoperative complications. The only postoperative complication has been a pyohydronephrosis in a patient not having internal drainage that was solved by percutaneous pyelostomy and didn't need reintervention. The postoperative handling of the pain was good by means of caudal locorregional anesthesia or by infiltration of the wound with local anesthesic and a dose of Ibuprofeno previous to leave the hospital. The mean hospital stay was 2 days (1-3 days) excluding the complicated case. Postoperative diuretic renograms at the 6 and 18 have shown absence of obstruction in all cases. In the long term follow-up, in 1 case nephrectomy was performed. The PARA for UPJ obstruction is a safe and effective procedure with the advantage of a minimal invasive approach that facilitates the reconstruction of the ureteropielic junction. Reduces operative time and hospital stay, with appropriate postoperative results. In our experience PARA constitutes an alternative to the conventional pyeloplasty and laparoscopic pyeloplasty in the pediatric age.
Coons, David A; Barber, F Alan; Herbert, Morley A
2006-11-01
This study evaluated the strength and suture-tendon interface security of different suture configurations from triple-suture-loaded anchors. A juvenile bovine infraspinatus tendon was detached and repaired by use of 4 different suture combinations from 2 suture anchors: 3 simple sutures in each anchor (ThreeVo anchor; Linvatec, Largo, FL); 2 peripheral simple stitches and 1 central horizontal mattress suture passed deeper into the tendon, creating a larger footprint (bigfoot-print anchor); 2 peripheral simple stitches with 1 central horizontal mattress stitch passed through the same holes as the simple sutures (stitch-of-Burns); and 2 simple stitches (TwoVo anchor; Linvatec). The constructs were cyclically loaded between 10 N and 180 N for 3,500 cycles and then destructively tested. The number of cycles required to create a 5-mm gap and a 10-mm gap and the ultimate load to failure and failure mode were recorded. The ThreeVo anchor was strongest and most resistant to cyclic loading (P < .01). The TwoVo anchor was least resistant to cyclic loading. The stitch-of-Burns anchor was more resistant to cyclic loading than both the bigfoot-print anchor and the TwoVo anchor (P < .03). The ThreeVo, stitch-of-Burns, and TwoVo anchors were stronger than the bigfoot-print anchor (P < .05). Three simple sutures in an anchor hold better than two simple sutures. Three simple sutures provide superior suture-tendon security than combinations of one mattress and two simple stitches subjected to cyclic loading. A central mattress stitch placed more medially than two peripheral simple stitches (bigfoot-print anchor) configured to enlarge the tendon-suture footprint was not as resistant to cyclic loading or destructive testing as three simple stitches (ThreeVo anchor). Placing a central mattress stitch more medially than 2 peripheral simple stitches to enlarge the tendon-suture footprint was not as resistant to cyclic loading or destructive testing as 3 simple stitches.
Shibazaki-Yorozuya, Reiko; Wang, Qian; Dechow, Paul C; Maki, Koutaro; Opperman, Lynne A
2012-06-01
Craniofacial sutures are bone growth fronts that respond and adapt to biomechanical environments. Little is known of the role sutures play in regulating the skull biomechanical environment during patency and fusion conditions, especially how delayed or premature suture fusion will impact skull biomechanics. Tgf-β3 has been shown to prevent or delay suture fusion over the short term in rat skulls, yet the long-term patency or its consequences in treated sutures is not known. It was therefore hypothesized that Tgf-β3 had a long-term impact to prevent suture fusion and thus alter the skull biomechanics. In this study, collagen gels containing 3 ng Tgf-β3 were surgically placed superficial to the posterior interfrontal suture (IFS) and deep to the periosteum in postnatal day 9 (P9) rats. At P9, P24, and P70, biting forces and strains over left parietal bone, posterior IFS, and sagittal suture were measured with masticatory muscles bilaterally stimulated, after which the rats were sacrificed and suture patency analyzed histologically. Results demonstrated that Tgf-β3 treated sutures showed less fusion over time than control groups, and strain patterns in the skulls of the Tgf-β3-treated group were different from that of the control group. Although bite force increased with age, no alterations in bite force were attributable to Tgf-β3 treatment. These findings suggest that the continued presence of patent sutures can affect strain patterns, perhaps when higher bite forces are present as in adult animals. Copyright © 2012 Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Priester, Carolina; Dillaman, Richard M.; Gay, D. Mark
2005-12-01
The ecdysial suture is the region of the arthropod exoskeleton that splits to allow the animal to emerge during ecdysis. We examined the morphology and composition of the intermolt and premolt suture of the blue crab using light microscopy and scanning electron microscopy. The suture could not be identified by routine histological techniques; however 3 of 22 fluorescein isothiocyanate-labeled lectins tested (Lens culinaris agglutinin, Vicia faba agglutinin, and Pisum sativum agglutinin) differentiated the suture, binding more intensely to the suture exocuticle and less intensely to the suture endocuticle. Back-scattered electron (BSE) and secondary electron observations of fracture surfaces of intermolt cuticle showed less mineralized regions in the wedge-shaped suture as did BSE analysis of premolt and intermolt resin-embedded cuticle. The prism regions of the suture exocuticle were not calcified. X-ray microanalysis of both the endocuticle and exocuticle demonstrated that the suture was less calcified than the surrounding cuticle with significantly lower magnesium and phosphorus concentrations, potentially making its mineral more soluble. The presence or absence of a glycoprotein in the organic matrix, the extent and composition of the mineral deposited, and the thickness of the cuticle all likely contribute to the suture being removed by molting fluid, thereby ensuring successful ecdysis.
Bailleul, Alida M; Horner, John R
2016-08-01
Sutures and synchondroses, the fibrous and cartilaginous articulations found in the skulls of vertebrates, have been studied for many biological applications at the morphological scale. However, little is known about these articulations at the microscopic scale in non-mammalian vertebrates, including extant archosaurs (birds and crocodilians). The major goals of this paper were to: (i) document the microstructure of some sutures and synchondroses through ontogeny in archosaurs; (ii) compare these microstructures with previously published sutural histology (i.e. that of mammals); and (iii) document how these articulations with different morphological degrees of closure (open or obliterated) appear histologically. This was performed with histological analyses of skulls of emus, American alligators, a fossil crocodilian and ornithischian dinosaurs (hadrosaurids, pachycephalosaurids and ceratopsids). Emus and mammals possess a sutural periosteum until sutural fusion, but it disappears rapidly during ontogeny in American alligators. This study identified seven types of sutural mineralized tissues in extant and extinct archosaurs and grouped them into four categories: periosteal tissues; acellular tissues; fibrous tissues; and intratendinous tissues. Due to the presence of a periosteum in their sutures, emus and mammals possess periosteal tissues at their sutural borders. The mineralized sutural tissues of crocodilians and ornithischian dinosaurs are more variable and can also develop via a form of necrosis for acellular tissues and metaplasia for fibrous and intratendinous tissues. It was hypothesized that non-avian dinosaurs, like the American alligator, lacked a sutural periosteum and that their primary mode of ossification involved the direct mineralization of craniofacial sutures (instead of intramembranous ossification found in mammals and birds). However, we keep in mind that a bird-like sutural microstructure might have arisen within non-avian saurichians. While synchondroseal histology is relatively similar in archosaurs and mammals, the microstructural differences between the sutures of these two clades are undeniable. Moreover, the current results suggest that the degree of sutural closure can only accurately be known via microstructural analyses. This study sheds light on the microstructure and growth of archosaurian sutures and synchondroses, and reveals a unique, undocumented histological diversity in non-avian dinosaur skulls. © 2016 Anatomical Society.
Code of Federal Regulations, 2013 CFR
2013-01-01
... shells, shells not split on suture, adhering hull material, light stained, or dark stained. (1) Damage by... shell surface or, on dyed nuts, when readily noticeable. (v) Dark stained on raw or roasted nuts, means an aggregate amount of dark brown, dark gray or black discoloration affects more than one-eighth of...
Code of Federal Regulations, 2014 CFR
2014-01-01
... shells, shells not split on suture, adhering hull material, light stained, or dark stained. (1) Damage by... shell surface or, on dyed nuts, when readily noticeable. (v) Dark stained on raw or roasted nuts, means an aggregate amount of dark brown, dark gray or black discoloration affects more than one-eighth of...
Izbicki, J R; Gawad, K A; Quirrenbach, S; Hosch, S B; Breid, V; Knoefel, W T; Küpper, H U; Broelsch, C E
1998-07-01
Hospitals are facing increasing economic pressure. It therefore seems necessary to evaluate the efficiency and effectiveness of medical or surgical interventions. In this study 324 anastomoses (167 stapled and 157 hand-sewn) were performed after randomization during 200 elective operations [20.5% gastrectomies, 14% gastric resections (Billroth II), 15% Whipple's procedures, 4% segmental colonic resections, 18% right-sided hemicolectomies, 4% left-sided hemicolectomies, 22% sigmoid- or anterior rectal resections, 2.5% total colectomies with pouch-anal anastomoses] in 200 patients. Postoperative motility (time to full oral diet, time with naso-gastric tube) and hospitalization were comparable in both groups. Anastomotic insufficiency was observed in 2.1% of all patients, five after stapled and two after hand-sewn anastomoses. Hospital mortality was 1.5%. All stapled anastomoses were performed significantly (P < 0.001) faster. However, the cost of material for these anastomoses was significantly (P < 0.001) higher, resulting in significantly higher total costs for reconstruction. The time saving for the reconstruction did not influence the total operative time (except for stapled gastrectomy). Therefore, all operations with stapled reconstruction were more expensive than those with sutured reconstruction. The difference was significant for the gastrectomy (P < 0.01), colonic resection (P < 0.01) and sigmoid and rectal resection (P < 0.001) groups. Stapled and sutured anastomoses are equally effective. Stapled anastomoses are not efficient, however, and should be reserved for individual indications.
Kuck, Laura; Seitz, Florian; Wiegering, Armin; Dietz, Ulrich; Meyer, Thomas
2017-11-22
Summary Umbilical hernia occur in both adults and children. For over 100 years, umbilical hernia in children has been treated surgically by the Spitzy method. With adult patients, meshes are being increasingly used. The purpose of our study was to analyse Spitzy herniotomy with respect to the recurrence rate in children and adults. Material and Methods Over a period of 7 years, 383 children (age < 16 years) with umbilical hernia were treated surgically; after applying the exclusion criteria, 370 patients were evaluated. At the same time, 106 adult patients (age > 16 years) were operated for an umbilical hernia: 31 patients were treated with direct suture and thus are included in our study as comparison group. Results The young patients had an average age of 33.81 months and were 44% female and 56% male. After direct Spitzy suture, a low recurrence rate of 1.1% (n = 4) in infancy could be achieved. The average age of the adult patients was 54.55 years; 32% were female, 68% male. In comparison to the group of children, the recurrence rate in adult surgery was 12.9% (n = 4) after direct suture. Conclusion As confirmed in our study, umbilical herniotomy by direct suture in childhood has been the method of choice and gold standard for more than 100 years. Mesh implantation is still not necessary in childhood. Georg Thieme Verlag KG Stuttgart · New York.
An Anatomic and Biomechanical Comparison of Bankart Repair Configurations.
Judson, Christopher H; Voss, Andreas; Obopilwe, Elifho; Dyrna, Felix; Arciero, Robert A; Shea, Kevin P
2017-11-01
Suture anchor repair for anterior shoulder instability can be performed using a number of different repair techniques, but none has been proven superior in terms of anatomic and biomechanical properties. Purpose/Hypothesis: The purpose was to compare the anatomic footprint coverage and biomechanical characteristics of 4 different Bankart repair techniques: (1) single row with simple sutures, (2) single row with horizontal mattress sutures, (3) double row with sutures, and (4) double row with labral tape. The hypotheses were as follows: (1) double-row techniques would improve the footprint coverage and biomechanical properties compared with single-row techniques, (2) horizontal mattress sutures would increase the footprint coverage compared with simple sutures, and (3) repair techniques with labral tape and sutures would not show different biomechanical properties. Controlled laboratory study. Twenty-four fresh-frozen cadaveric specimens were dissected. The native labrum was removed and the footprint marked and measured. Repair for each of the 4 groups was performed, and the uncovered footprint was measured using a 3-dimensional digitizer. The strength of the repair sites was assessed using a servohydraulic testing machine and a digital video system to record load to failure, cyclic displacement, and stiffness. The double-row repair techniques with sutures and labral tape covered 73.4% and 77.0% of the footprint, respectively. These percentages were significantly higher than the footprint coverage achieved by single-row repair techniques using simple sutures (38.1%) and horizontal mattress sutures (32.8%) ( P < .001). The footprint coverage of the simple suture and horizontal mattress suture groups was not significantly different ( P = .44). There were no significant differences in load to failure, cyclic displacement, or stiffness between the single-row and double-row groups or between the simple suture and horizontal mattress suture techniques. Likewise, there was no difference in the biomechanical properties of the double-row repair techniques with sutures versus labral tape. Double-row repair techniques provided better coverage of the native footprint of the labrum but did not provide superior biomechanical properties compared with single-row repair techniques. There was no difference in footprint coverage or biomechanical strength between the simple suture and horizontal mattress suture repair techniques. Although the double-row repair techniques had no difference in initial strength, they may improve healing in high-risk patients by improving the footprint coverage.
Horizontal Running Mattress Suture Modified with Intermittent Simple Loops
Chacon, Anna H; Shiman, Michael I; Strozier, Narissa; Zaiac, Martin N
2013-01-01
Using the combination of a horizontal running mattress suture with intermittent loops achieves both good eversion with the horizontal running mattress plus the ease of removal of the simple loops. This combination technique also avoids the characteristic railroad track marks that result from prolonged non-absorbable suture retention. The unique feature of our technique is the incorporation of one simple running suture after every two runs of the horizontal running mattress suture. To demonstrate its utility, we used the suturing technique on several patients and analyzed the cosmetic outcome with post-operative photographs in comparison to other suturing techniques. In summary, the combination of running horizontal mattress suture with simple intermittent loops demonstrates functional and cosmetic benefits that can be readily taught, comprehended, and employed, leading to desirable aesthetic results and wound edge eversion. PMID:23723610
Peer-assisted teaching of basic surgical skills.
Preece, Ryan; Dickinson, Emily Clare; Sherif, Mohamed; Ibrahim, Yousef; Ninan, Ann Susan; Aildasani, Laxmi; Ahmed, Sartaj; Smith, Philip
2015-01-01
Basic surgical skills training is rarely emphasised in undergraduate medical curricula. However, the provision of skills tutorials requires significant commitment from time-constrained surgical faculty. We aimed to determine how a peer-assisted suturing workshop could enhance surgical skills competency among medical students and enthuse them towards a career in surgery. Senior student tutors delivered two suturing workshops to second- and third- year medical students. Suturing performance was assessed before and after teaching in a 10-min suturing exercise (variables measured included number of sutures completed, suture tension, and inter-suture distance). Following the workshop, students completed a questionnaire assessing the effect of the workshop on their suturing technique and their intention to pursue a surgical career. Thirty-five students attended. Eighty-one percent believed their medical school course provided insufficient basic surgical skills training. The mean number of sutures completed post-teaching increased significantly (p < 0.001), and the standard deviation of mean inter-suture distance halved from ± 4.7 mm pre-teaching, to ± 2.6 mm post-teaching. All students found the teaching environment to be relaxed, and all felt the workshop helped to improve their suturing technique and confidence; 87% found the peer-taught workshop had increased their desire to undertake a career in surgery. Peer-assisted learning suturing workshops can enhance medical students' competence with surgical skills and inspire them towards a career in surgery. With very little staff faculty contribution, it is a cheap and sustainable way to ensure ongoing undergraduate surgical skills exposure.
Cray, James; Cooper, Gregory M; Mooney, Mark P; Siegel, Michael I
2011-05-01
Research has shown that Pan and Homo have similar ectocranial suture synostosis patterns and a similar suture ontogeny (relative timing of suture fusion during the species ontogeny). This ontogeny includes patency during and after neurocranial expansion with a delayed bony response associated with adaptation to biomechanical forces generated by mastication. Here we investigate these relationships for Gorilla by examining the association among ectocranial suture morphology, cranial volume (as a proxy for neurocranial expansion) and dental development (as a proxy for the length of time that it has been masticating hard foods and exerting such strains on the cranial vault) in a large sample of Gorilla gorilla skulls. Two-hundred and fifty-five Gorilla gorilla skulls were examined for ectocranial suture closure status, cranial volume and dental eruption. Regression models were calculated for cranial volumes by suture activity, and Kendall's tau (a non-parametric measure of association) was calculated for dental eruption status by suture activity. Results suggest that, as reported for Pan and Homo, neurocranial expansion precedes suture synostosis activity. Here, Gorilla was shown to have a strong relationship between dental development and suture activity (synostosis). These data are suggestive of suture fusion extending further into ontogeny than brain expansion, similar to Homo and Pan. This finding allows for the possibility that masticatory forces influence ectocranial suture morphology. © 2011 The Authors. Journal of Anatomy © 2011 Anatomical Society of Great Britain and Ireland.
Schneider, Jochen; Harrasser, Norbert; Tübel, Jutta; Mühlhofer, Heinrich; Pförringer, Dominik; von Deimling, Constantin; Foehr, Peter; Kiefel, Barbara; Krämer, Christina; Stemberger, Axel; Schieker, Matthias
2018-01-01
Background Surgical sutures can promote migration of bacteria and thus start infections. Antiseptic coating of sutures may inhibit proliferation of adhered bacteria and avoid such complications. Objectives This study investigated the inhibition of viable adhering bacteria on novel antimicrobially coated surgical sutures using chlorhexidine or octenidine, a critical factor for proliferation at the onset of local infections. The medical need, a rapid eradication of bacteria in wounds, can be fulfilled by a high antimicrobial efficacy during the first days after wound closure. Methods As a pretesting on antibacterial efficacy against relevant bacterial pathogens a zone of inhibition assay was conducted with middle ranged concentrated suture coatings (22 μg/cm). For further investigation of adhering bacteria in detail the most clinically relevant Staphylococcus aureus (ATCC®49230™) was used. Absorbable braided sutures were coated with chlorhexidine-laurate, chlorhexidine-palmitate, octenidine-laurate, and octenidine-palmitate. Each coating type resulted in 11, 22, or 33 μg/cm drug content on sutures. Scanning electron microscopy (SEM) was performed once to inspect the coating quality and twice to investigate if bacteria have colonized on sutures. Adhesion experiments were assessed by exposing coated sutures to S. aureus suspensions for 3 h at 37°C. Subsequently, sutures were sonicated and the number of viable bacteria released from the suture surface was determined. Furthermore, the number of viable planktonic bacteria was measured in suspensions containing antimicrobial sutures. Commercially available sutures without drugs (Vicryl®, PGA Resorba®, and Gunze PGA), as well as triclosan-containing Vicryl® Plus were used as control groups. Results Zone of inhibition assay documented a multispecies efficacy of novel coated sutures against tested bacterial strains, comparable to most relevant S. aureus over 48 hours. SEM pictures demonstrated uniform layers on coated sutures with higher roughness for palmitate coatings and sustaining integrity of coated sutures. Adherent S. aureus were found via SEM on all types of investigated sutures. The novel antimicrobial sutures showed significantly less viable adhered S. aureus bacteria (up to 6.1 log) compared to Vicryl® Plus (0.5 log). Within 11 μg/cm drug-containing sutures, octenidine-palmitate (OL11) showed the highest number of viable adhered S. aureus (0.5 log), similar to Vicryl® Plus. Chlorhexidine-laurate (CL11) showed the lowest number of S. aureus on sutures (1.7 log), a 1.2 log greater reduction. In addition, planktonic S. aureus in suspensions were highly inhibited by CL11 (0.9 log) represents a 0.6 log greater reduction compared to Vicryl® Plus (0.3 log). Conclusions Novel antimicrobial sutures can potentially limit surgical site infections caused by multiple pathogenic bacterial species. Therefore, a potential inhibition of multispecies biofilm formation is assumed. In detail tested with S. aureus, the chlorhexidine-laurate coating (CL11) best meets the medical requirements for a fast bacterial eradication. This suture coating shows the lowest survival rate of adhering as well as planktonic bacteria, a high drug release during the first–clinically most relevant– 48 hours, as well as biocompatibility. Thus, CL11 coatings should be recommended for prophylactic antimicrobial sutures as an optimal surgical supplement to reduce wound infections. However, animal and clinical investigations are important to prove safety and efficacy for future applications. PMID:29315313
Obermeier, Andreas; Schneider, Jochen; Harrasser, Norbert; Tübel, Jutta; Mühlhofer, Heinrich; Pförringer, Dominik; Deimling, Constantin von; Foehr, Peter; Kiefel, Barbara; Krämer, Christina; Stemberger, Axel; Schieker, Matthias; Burgkart, Rainer; von Eisenhart-Rothe, Rüdiger
2018-01-01
Surgical sutures can promote migration of bacteria and thus start infections. Antiseptic coating of sutures may inhibit proliferation of adhered bacteria and avoid such complications. This study investigated the inhibition of viable adhering bacteria on novel antimicrobially coated surgical sutures using chlorhexidine or octenidine, a critical factor for proliferation at the onset of local infections. The medical need, a rapid eradication of bacteria in wounds, can be fulfilled by a high antimicrobial efficacy during the first days after wound closure. As a pretesting on antibacterial efficacy against relevant bacterial pathogens a zone of inhibition assay was conducted with middle ranged concentrated suture coatings (22 μg/cm). For further investigation of adhering bacteria in detail the most clinically relevant Staphylococcus aureus (ATCC®49230™) was used. Absorbable braided sutures were coated with chlorhexidine-laurate, chlorhexidine-palmitate, octenidine-laurate, and octenidine-palmitate. Each coating type resulted in 11, 22, or 33 μg/cm drug content on sutures. Scanning electron microscopy (SEM) was performed once to inspect the coating quality and twice to investigate if bacteria have colonized on sutures. Adhesion experiments were assessed by exposing coated sutures to S. aureus suspensions for 3 h at 37°C. Subsequently, sutures were sonicated and the number of viable bacteria released from the suture surface was determined. Furthermore, the number of viable planktonic bacteria was measured in suspensions containing antimicrobial sutures. Commercially available sutures without drugs (Vicryl®, PGA Resorba®, and Gunze PGA), as well as triclosan-containing Vicryl® Plus were used as control groups. Zone of inhibition assay documented a multispecies efficacy of novel coated sutures against tested bacterial strains, comparable to most relevant S. aureus over 48 hours. SEM pictures demonstrated uniform layers on coated sutures with higher roughness for palmitate coatings and sustaining integrity of coated sutures. Adherent S. aureus were found via SEM on all types of investigated sutures. The novel antimicrobial sutures showed significantly less viable adhered S. aureus bacteria (up to 6.1 log) compared to Vicryl® Plus (0.5 log). Within 11 μg/cm drug-containing sutures, octenidine-palmitate (OL11) showed the highest number of viable adhered S. aureus (0.5 log), similar to Vicryl® Plus. Chlorhexidine-laurate (CL11) showed the lowest number of S. aureus on sutures (1.7 log), a 1.2 log greater reduction. In addition, planktonic S. aureus in suspensions were highly inhibited by CL11 (0.9 log) represents a 0.6 log greater reduction compared to Vicryl® Plus (0.3 log). Novel antimicrobial sutures can potentially limit surgical site infections caused by multiple pathogenic bacterial species. Therefore, a potential inhibition of multispecies biofilm formation is assumed. In detail tested with S. aureus, the chlorhexidine-laurate coating (CL11) best meets the medical requirements for a fast bacterial eradication. This suture coating shows the lowest survival rate of adhering as well as planktonic bacteria, a high drug release during the first-clinically most relevant- 48 hours, as well as biocompatibility. Thus, CL11 coatings should be recommended for prophylactic antimicrobial sutures as an optimal surgical supplement to reduce wound infections. However, animal and clinical investigations are important to prove safety and efficacy for future applications.
[Application of inner figure-of-eight suture to laparoscopic colorectal surgery].
Chen, Jianjun; Zhong, Ming
2018-03-25
Regardless of laparoscopic or open colorectal surgeries, intestinal anastomosis is usually an important operative procedure. Even if stapler is widely used in different intestinal surgery nowadays, hand sewn suture is an indispensable procedure in clinical practice, meanwhile after stapled anastomosis, additional hand sewn suture is usually performed to ensure the safety of anastomosis. The inner figure-of-eight suture is a single layer suture technique which has been widely used in skin, tendon, rectus and uterus for quick and secure approximation. We describe our innovative application of inner figure-of-eight suture technique for intestinal anastomosis and/or reinforcement after stapled anastomosis in laparoscopic colorectal surgery. Main steps of inner figure-of-eight suture for intestinal anastomosis on posterior wall are as follows: (1) At 4 mm from cut edge of bowel, needle enters vertically from one side and courses mucosa-serosa-opposite serosa-mucosa in parallel to the entry point. (2) The needle is brought back to first entry side of bowel at 45 degree to enter the mucosa 5 mm below the first entry point and out on opposite side mucosa horizontally. (3) Both lose ends of the suture are pulled to approximate bowel edges and knots are tied on mucosal surface, in which suture line presents figure-of-eight on mucosal surface and two parallel suture lines are seen on serosal surface. When inner figure-of-eight suture is performed on anterior wall, the procedure is similar, but needle passes from serosa-mucosa-opposite mucosa-serosa and repeated to complete the inner figure-8 suture and knots are tied on serosa. The final look is two parallel sutures at 0.5 mm in between and the figure-of-eight remains inside the lumen. We did not deliberately try to invert the bowel edges, and if anastomosis is not satisfactory at final examination, simple interrupted seromuscular suture can be carried out. From 2015 till now, we have successfully completed inner figure-of-eight sutures in 38 cases receiving intestinal anastomosis reinforcement procedure and in 24 cases receiving hand sewn anastomosis. Comparison study revealed inner figure-of-eight suture presented shorter anastomotic time and less medical cost without anastomotic leakage, stump leakage or bleeding. No anastomotic stenosis was found at enteroscopy examination during follow up. We think that inner figure-of-eight suture possesses safe and simple advantages and is a manual suture technique worthy of promotion.
Khonsari, R H; Di Rocco, F; Arnaud, E; Sanchez, S; Tafforeau, P
2012-09-01
The developmental genetics and the biomechanics of sutures are well-studied topics, while their microanatomy is still imperfectly known. Here, we aim to investigate the structure of skull vault sutures using a high-resolution imaging device. We used synchrotron X-ray microtomography in order to obtain high-resolution images of skull vault sutures from an extant mammal (the mouse Mus musculus) and from an extinct fish (the placoderm Compagopiscis croucheri). We used segmentation and 3D reconstruction softwares in order to reveal the microanatomy of sutures in these species. The high-resolution images allowed us to study the distribution of osteocytes, the organisation of vascular canals, the shapes of the suture borders, the insertion of Sharpey's fibres, the bone growth lines and the structure of the soft tissues surrounding the sutures. Synchrotron imaging provides new perspectives for the study of the normal microanatomy of sutures. The submicronic resolution of the synchrotron scans gives access to the 3D organisation of structures that were previously only known in 2D, even in normal sutures. The description of anatomical entities such as vascular canals and Sharpey's fibres in abnormally fused sutures would be of interest in the understanding of craniosynostoses.
[Mechanical suture in colorectal surgery].
Alecu, L; Pascu, A; Costan, I; Deacu, A; Marin, A; Corodeanu, G; Gulinescu, L
2001-01-01
Of this work was the study of using, as well as the utility of the mechanical sutures in colorectal surgery; because of the special caution needed to be taken for any colonic or rectal suture, more than any other digestive segment. The frequency of the postoperative fistulas after the suture and anastomosis is higher at this level and so it increases the period and costs of the hospitalization. We studied the possibilities of performing and evolution of 64 mechanical sutures for 19 patients, with colorectal pathology, hospitalized in our department from july 1999 to december 2000. We performed 64 mechanical sutures, as followed: 47 in open surgery and 17 in laparoscopic. From all these, 56 was bowel sutures, 8 of them were vascular (in laparoscopic, for cutting the most important vascular pedicles). We did 18 anastomosis: 15 in open and 3 in laparoscopic surgery. It was 2 postoperative fistulas from all 56 intestinal sutures (3.57%). We haven't any intra or postoperative bleeding from the vascular anastomosis. It was 3 intraoperative bleeding from the intestinal anastomosis, and only 1 case of postoperative bleeding (5.26% of the cases: 1.56% of all mechanical sutures). In only one case, the mechanical suture couldn't be initially done, but it succeeded after the removing of the segment of the bowel involved. Mechanical sutures offers a high level of safety to the colorectal anastomosis. It provides a very good vascularization to the anastomosis and decreases the time needed for performing the suture or anastomosis, versus manual sature. Also, for the patients with rectal ampular neoplasm, it creates the possibility of anal sphincter preservation by making a low colorectal anastomoses--which is difficult by manual suture.
Gastric full-thickness suturing during EMR and for treatment of gastric-wall defects (with video).
von Renteln, Daniel; Schmidt, Arthur; Riecken, Bettina; Caca, Karel
2008-04-01
The endoscopic full-thickness Plicator device was initially developed to provide an endoscopic treatment option for patients with GERD. Because the endoscopic full-thickness Plicator enables rapid and easy placement of transmural sutures, comparable with surgical sutures, we used the Plicator device for endoscopic treatment or prevention of GI-wall defects. To describe the outcomes and complications of endoscopic full-thickness suturing during EMR and for the treatment of gastric-wall defects. A report of 4 cases treated with the endoscopic full-thickness suturing between June 2006 and April 2007. A large tertiary-referral center. Four subjects received endoscopic full-thickness suturing. The subjects were women, with a mean age of 67 years. Of the 4 subjects, 3 received endoscopic full-thickness suturing during or after an EMR. One subject received endoscopic full-thickness suturing for treatment of a fistula. Primary outcome measurements were clinical procedural success and procedure-related adverse events. The mean time for endoscopic full-thickness suturing was 15 minutes. In all cases, GI-wall patency was restored or ensured, and no procedure-related complications occurred. All subjects responded well to endoscopic full-thickness suturing. The resection of one GI stromal tumor was incomplete. Because of the Plicator's 60F distal-end diameter, endoscopic full-thickness suturing could only be performed with the patient under midazolam and propofol sedation. The durable Plicator suture might compromise the endoscopic follow-up after EMR. The endoscopic full-thickness Plicator permits rapid and easy placement of transmural sutures and seems to be a safe and effective alternative to surgical intervention to restore GI-wall defects or to ensure GI-wall patency during EMR procedures.
Cranial suture complexity in caviomorph rodents (Rodentia; Ctenohystrica).
Buezas, Guido; Becerra, Federico; Vassallo, Aldo
2017-08-01
Due to their flexibility, sutures are regions that experience greater strains than the surrounding rigid cranial bones. Cranial sutures differ in their degree of interdigitation or complexity. There is evidence indicating that a more convoluted suture better enables the absorption of high stresses coming from dynamic masticatory forces, and other functions. The Order Rodentia is an interesting clade to study this because of its taxa with diverse chewing modes. Due to repeated loading resulting from gnawing and grinding, energy absorption by the sutures might be a crucial factor in these mammals. Species within the infraorder Caviomorpha were chosen as a case study because of their ecomorphological and dietary diversity. This study compared five sutures from the rostrum and cranial vault across seven caviomorph families, and assessed their complexity by means of the relative length and fractal dimension. Across these rodents, cranial sutures are morphologically quite diverse. We found that the sutures connecting the rostrum with the vault were relatively more interdigitated than those in the cranial vault itself, especially premaxillofrontal sutures. Suture interdigitation was higher in species that display chisel-tooth digging and burrowing behaviors, especially in the families Ctenomyidae and Octodontidae, than those in families Dasyproctidae and Cuniculidae, which have more gracile masticatory systems. The reconstruction of the ancestral character state, on family and species phylogeny, points toward low suture interdigitation (i.e., low length ratio) as a likely ancestral state for interfrontal, premaxillofrontal and maxillofrontal sutures. Interspecific differences in suture morphology shown here might represent adaptations to different mechanical demands (i.e., soft vs. tough foods) or behaviors (e.g., chisel-tooth digging), which evolved in close association with the diverse environments occupied by caviomorph rodents. © 2017 Wiley Periodicals, Inc.
Laparoscopic percutaneous jejunostomy with intracorporeal V-Loc jejunopexy in esophageal cancer.
Yang, Shun-Mao; Hsiao, Wei-Ling; Lin, Jui-Hsiang; Huang, Pei-Ming; Lee, Jang-Ming
2017-06-01
Barbed sutures are widely used in various laparoscopic digestive surgeries. The purpose of this paper is to present our initial experience of laparoscopic percutaneous jejunostomy with unidirectional barbed sutures in esophageal cancer patients and compare it with our early cases using traditional transabdominal sutures. A total of 118 esophageal cancer patients who underwent laparoscopic percutaneous jejunostomy were identified in a single institution in Taiwan from June 2014 to May 2016. The authors' traditional technique consisted of using transabdominal sutures with bolsters to fix a jejunum loop onto the anterior abdominal wall. A novel technique was introduced using intracorporeal suturing with knotless unidirectional barbed monofilament absorbable sutures (V-Loc) to attain a seal around the feeding catheter. A comparison between these two techniques was performed. Twenty cases with barbed V-Loc sutures and 98 cases with transabdominal sutures were identified. The V-Loc sutures appeared to reduce peristomal skin ulcers (19.4 vs. 0 %, p = 0.040), postoperative pain scores during the first 24 h (1.8 ± 1.4 vs. 0.9 ± 1.1, p = 0.007) and on postoperative day 2 (1.7 ± 1.4 vs. 1.0 ± 0.8, p = 0.026) when compared to patients receiving transabdominal sutures. The mean suturing time using V-Loc sutures was 22 min (14-60 min). The mean onset to resumption of enteral feeding was 1.8 ± 0.8 days and the mean duration of postoperative hospital stay was 8 ± 5.1 days, both of which were comparable in the two groups. There was no surgical mortality in our series. In the study cohort, the use of knotless unidirectional barbed sutures instead of traditional transabdominal sutures had similar outcomes and appears to be a feasible option for intracorporeal jejunopexy when performing laparoscopic jejunostomy in patients with esophageal cancer.
Huh, Beom Kang; Kim, Byung Hwi; Kim, Se-Na; Park, Chun Gwon; Lee, Seung Ho; Kim, Ka Ryeong; Heo, Chan Yeong; Choy, Young Bin
2017-10-01
In this work, we propose a surgical suture that can sustainably release diclofenac (DF) for the local pain relief of surgical wounds. We separately fabricated a DF-loaded strand composed of a biodegradable polymer, poly(lactic-co-glycolic acid) (PLGA), which was then braided with a surgical suture already in clinical use, i.e., VICRYL™. In this way, the drug-delivery suture presented herein could release DF in a sustained manner for 10days while maintaining the mechanical strength needed for wound closure. According to the in vivo results of an induced-pain animal model, the drug-delivery suture mitigated pain throughout the period of persistent pain. The histological analysis of tissue around the sutures showed that the drug-delivery suture exhibited biocompatibility comparable to that of the VICRYL™ suture in clinical use. Copyright © 2017 Elsevier B.V. All rights reserved.
Perioperative Modulating Factors on Astigmatism in Sutured Cataract Surgery
Cho, Yang Kyeung
2009-01-01
Purpose To evaluate the factors that affect postoperative astigmatism and post-suture removal astigmatism, and to evaluate the risk factors associated with astigmatism axis shift. Methods We performed a retrospective chart review of 130 eyes that had undergone uneventful phacoemulsification cataract surgery. Preoperative astigmatism was divided into four groups (Groups I, II, III, and IV) according to the differences between the axis of preoperative astigmatism (flattest axis) and the incision axis (105 degrees). We analyzed the magnitude and axis of the induced astigmatism after the operation and after suture removal in each group. We also analyzed the factors which affected the postoperative astigmatism and post-suture removal astigmatism in each sub-group of Groups I, II, III, and IV, excluding postoperative or post-suture removal axis shift (specifically, Group IWAS, IIWAS, IIIWAS, and IVWAS). We identified the variables associated with the prevalence of postoperative astigmatism axis shift and those associated with the prevalence of post-suture removal axis shift. Results An increase in the magnitude of postoperative astigmatism was associated with an increase in the preoperative magnitude of astigmatism in Groups IWAS, IIWAS, and IIIWAS (p<0.05), and with an increase in the corneal tunnel length in Group IWAS. A decrease in the magnitude of postoperative astigmatism was associated with an increase in the corneal tunnel length in Groups IIIWAS and IVWAS (p<0.05). An increase in the magnitude of post-suture removal astigmatism was associated with an increase in the magnitude of postoperative astigmatism in Groups IWAS and IVWAS (p<0.05), and with late suture removal in Group IVWAS (p<0.05). A decrease in the magnitude of post-suture removal astigmatism was associated with late suture removal in Groups IWAS and IIWAS. A logistic regression analysis showed that the prevalence of post-suture removal astigmatism axis shift was associated with increased corneal tunnel length, decreased magnitude of postoperative astigmatism, and early suture removal. Conclusions In order to reduce postoperative and post-suture removal astigmatism, we recommend a short corneal tunnel length and late suture removal in patients with Group IWAS characteristics, late suture removal in Group IIWAS-like patients, long corneal tunnel length in Group IIIWAS-like patients, and long corneal tunnel length and early suture removal in patients with characteristics of Group IVWAS. PMID:20046682
Emam, T A; Hanna, G; Cuschieri, A
2002-02-01
Laparoscopic suturing is technically a demanding skill in laparoscopic surgery. Ergonomic experimental studies provide objective information on the important factors and variables that govern optimal endoscopic suturing. Our objective was to determine the optimum physical alignment, visual display, and direction of intracorporeal laparoscopic bowel suturing using infrared motion analysis and telemetric electromyography (EMG) systems. Ten surgeons participated in the study; each sutured 50-mm porcine small bowel enterotomies toward and away from the surgeon in the vertical and horizontal bowel plane with either isoplanar (image display corresponds with actual lie of the bowel) or nonisoplanar (bowel displayed horizontally but mounted vertically in the trainer and vice versa) display. The end points were the placement error score, execution time, leakage pressure, motion analysis, and telemetric EMG parameters of the surgeon's dominant upper limb. Suturing was demonstrably easier in the vertical than in the horizontal plane, resulting in a better task quality (placement error score, p < 0.0001; leakage pressure, p < 0.005) and shorter execution time (p < 0.05). Nonisoplanar display of the surgical anatomy degrades performance in terms of both task efficiency and task quality. On motion analysis, a wider angle of excursion and lower angular velocity were observed during the vertical suturing with isoplaner display. Compared to horizontal suturing, supination at the wrist was significantly greater during vertical than horizontal suturing (p < 0.05). Within each category (vertical vs horizontal suturing), the direction of suturing (toward/away from the surgeon) did not influence the extent of pronation/ supination at the wrist. In line with the degraded performance, significantly more muscle work was expended during horizontal suturing. This affected the forearm flexors (p < 0.05), arm flexors and extensors (p < 0.005 and p < 0.05, respectively), and deltoid muscles (p < 0.005) and was accompanied by significantly more fatigue in the related muscles. Small bowel enterotomies sutured toward the surgeon in both the vertical and the horizontal planes exhibited less placement error score than when sutured away from the surgeon, with no significant difference in the motion analysis and EMG parameters. Optimal laparoscopic suturing (better task quality and reduced execution time) is achieved with vertical suturing toward the surgeon with isoplanar monitor display of the operative field. The poorer task performance observed during horizontal suturing is accompanied by more muscle work and fatigue, and it is not improved by monitor display of the enterotomy in the vertical plane.
Non-metallic implant for patellar fracture fixation: A systematic review.
Camarda, Lawrence; Morello, Salvatore; Balistreri, Francesco; D'Arienzo, Antonio; D'Arienzo, Michele
2016-08-01
Despite good clinical outcome proposals, there has been relatively little published regarding the use of non-metallic implant for patellar fracture fixation. The purpose of the study was to perform a systematic literature review to summarize and evaluate the clinical studies that described techniques for treating patella fractures using non-metallic implants. A comprehensive literature search was systematically performed to evaluate all studies included in the literature until November 2015. The following search terms were used: patellar fracture, patella suture, patella absorbable, patella screw, patella cerclage. Two investigators independently reviewed all abstracts and the selection of these abstracts was then performed based on inclusion and/or exclusion criteria. A total of 9 studies involving 123 patients were included. Patients had a mean age of 33.7 years and were followed up for a mean of 18.9 months. The most common method for fracture fixations included the use of suture material. Good clinical outcomes were reported among all studies. Thirteen patients (10.5%) presented complications, while 4 patients (3.2%) required additional surgery for implant removal. There is a paucity of literature focused on the use of non-metallic implant for patellar fracture fixation. However, this systematic review showed that non-metallic implants are able to deliver good clinical outcomes reducing the rate of surgical complications and re-operation. These results may assist surgeons in choosing to use alternative material such as sutures to incorporate into their routine practice or to consider it, in order to reduce the rate of re-operation. Copyright © 2016 Elsevier Ltd. All rights reserved.
Kim, Dong Jin; Kim, Wook; Lee, Jun Hyun
2017-08-01
Intra-corporeal esophagojejunostomy (EJ) using a linear stapler creates a stapler entry hole that requires secure closure during the totally laparoscopic total gastrectomy (TLTG) procedure for gastric cancer. Since a standard method has not been established yet, the feasibility of using V-loc 180 (Covidien, Mansfield, MA, USA) suture material was evaluated in this study. During January 2012 to March 2015, 25 patients who underwent linear stapling EJ and V-loc 180 closure of remaining enterotomy were included in this study. Basic clinico-pathological characteristics, surgical outcomes, and short-term complications were analyzed. The mean patient age was 60.4 ± 8.5 years. Nineteen males and six females were included in this study. The mean body mass index was 25.3 ± 2.3 kg/m 2 . There were 22 stage-I, 2 stage-II, and 1 stage-III gastric cancer patients. The mean operation time was 240.5 ± 44.6 min, and the time for anastomosis was 38.8 ± 11.2 min. The procedures were successfully performed in all cases without any intra-operative complications. There was one case of EJ leakage that occurred at the corner of EJ staple line and not at the enterotomy closure site. The closure of the remaining enterotomy site using V-loc 180 suture following linear stapler EJ is technically feasible and safe during the TLTG procedure. However, further experience and results from other surgeons are necessary to generalize this procedure.
Office management of minor wounds.
Gouin, S.; Patel, H.
2001-01-01
OBJECTIVE: To review office interventions for minor wounds not requiring sutures, such as abrasions, bites, and lacerations. QUALITY OF EVIDENCE: Most information on minor wound management comes from descriptive studies. Few comparative studies examine the effectiveness of topical antisepsis for minor wounds. Several clinical trials have demonstrated that tissue adhesives produce short- and long-term cosmetic results equivalent to those achieved with suture materials. MAIN MESSAGE: Sterile saline is the least toxic solution for wound irrigation. Chlorhexidine (2%) and povidone iodine (10%) have been the most investigated antiseptic solutions. Systemic antibiotics are unnecessary for wounds unlikely to be infected. All bite wounds require special attention. Primary closure of bite wounds is indicated in certain circumstances: less than 12-hour-old nonpuncture wounds, uninfected wounds, and low-risk lesions (such as on the face). In spite of their many advantages, skin tapes should be used for low-tension wounds only. The popularity of tissue adhesives has greatly increased. Since the advent of newer products (with increased bonding strength and flexibility), adhesives are used to manage most lacerations except those in areas of high tension (e.g., joints) and on mucosal surfaces. CONCLUSION: Minor wounds not requiring sutures can be managed easily in the office. PMID:11340758
Suzuki, Yasutomo; Saito, Yuka; Ogushi, Satoko; Kimura, Go; Kondo, Yukihiro
2012-10-01
Herein we describe our experience with a bone-anchored sling using a suture anchor and polypropylene mesh for the treatment of post-radical prostatectomy urinary incontinence. Eight patients with urinary incontinence as a result of intrinsic sphincter deficiency after radical prostatectomy were included in the analysis. The procedure involved piercing the pubic bone with a bone drill, inserting the suture anchor and fixing a soft or rigid polypropylene mesh to press firmly on the bulbar urethra. Urinary incontinence was significantly improved according to changes in the daily number of pads used at 1, 3 and 6 months postoperatively in comparison with preoperatively. However, no meaningful improvement at 6 months postoperatively was seen with the soft mesh. Complications included perineal pain in four cases, but pain control was achieved using non-steroidal anti-inflammatory drugs. The bone-anchored sling with a suture anchor and polypropylene mesh appears to be safe and effective for the treatment of post-radical prostatectomy urinary incontinence. Soft mesh appears inappropriate as material for the bone-anchored sling because of the progressive likelihood of worsened urinary incontinence. © 2012 The Japanese Urological Association.
Eun, Sang Soo; Lee, Sang Ho; Sabal, Luigi Andrew
2016-08-01
There are numerous methods for repairing posterior root tears of the medial meniscus (PRTMM). Repair techniques using suture anchors through a high posteromedial portal have been reported. The present study found that using a knotless suture anchor instead of suture anchor seemed easier and faster because it avoided passing the sutures through the meniscus and tying a knot in a small space. This study describes a knotless suture anchor technique through a high posteromedial portal, and its clinical results. Copyright © 2016 Elsevier B.V. All rights reserved.
[Auto-suture stapler EEA in surgery of the colon and rectum [author's transl)].
Thiede, A; Troidl, H; Poser, H; Jostarndt, L; Hamelmann, H
1980-01-01
The increasing use of auto-suture staplers for gastrointestinal anastomoses makes it necessary to test the value of this new method of suturing. In a "pilot study" the practicability, the tightness and permeability of the anastomosis and complications were tested and analysed in a total of 30 colon and rectal anastomoses using the EEA-suture gun. The results of 14 colon resections and 16 low anterior resections justify the further use of the EEA auto-suture apparatus and raise the question of a prospective controlled random study in which manual and mechanical machine sutured anastomoses are compared.
Griesser, H J; Chatelier, R C; Martin, C; Vasic, Z R; Gengenbach, T R; Jessup, G
2000-01-01
Fine elastomeric sutures intended for cardiovascular surgery can exhibit "stick-slip" behavior as they are pulled through tissue; the resulting oscillatory force can damage delicate tissue or cause sutures to snap. To eliminate this undesirable effect, sutures were surface-modified using a radiofrequency glow discharge in a vapor of either hexamethyldisiloxane or hexamethyldisilazane, to produce a thin polymeric coating on the suture. The same coatings were also deposited onto aluminized tape to facilitate their characterization by measurement of air/water contact angles and by X-ray photoelectron spectroscopy. Coatings from both monomers were found to be very hydrophobic. The hexamethyldisiloxane glow discharge coatings underwent negligible oxidation when stored in air, and thus remained stable over a shelf-life period akin to what may be required of sutures. The hexamethyldisilazane glow discharge coatings, in contrast, incorporated substantial amounts of oxygen over a 3-month period. The coatings did not measurably alter the tensile properties of the sutures. The frictional properties of coated sutures were assessed by measuring the dynamic friction between the suture and ovine myocardium. Both coatings were effective in removing the inherent stick-slip behavior of polybutester sutures in this model. The coatings remained intact after several passes and proved to be robust and efficacious under various strain regimes. Copyright 2000 John Wiley & Sons, Inc.
Arthroscopically assisted acromioclavicular joint reconstruction.
Baumgarten, Keith M; Altchek, David W; Cordasco, Frank A
2006-02-01
Arthroscopically assisted acromioclavicular joint reconstruction avoids the large incisions necessary with open reconstructions. This acromioclavicular joint reconstruction technique via the subacromial space does not violate the rotator interval or require screw removal. The patient is placed in a modified beach-chair position. The arthroscope is placed into the subacromial space, and a bursectomy is performed through a lateral subacromial portal. The coracoacromial ligament is released from the acromion with an electrocautery and an arthroscopic elevator. A nonabsorbable suture is passed through the coracoacromial ligament with a suture passer, and an arthroscopic suture grasper is used to deliver both ends of the suture out through the lateral portal. The coracoid is identified and isolated using a radiofrequency ablator placed through the anterior portal while visualizing through the lateral portal. A percutaneous shuttle device is passed through the skin superomedial to the coracoid. The shuttle is visualized entering superior to the coracoid and is passed just medial to the coracoid. Once the tip of the shuttle can be visualized in the recess inferior to the coracoid, the shuttle loop is advanced. A suture grasper is used to deliver both ends of the shuttle out through the anterior portal. A semitendinosus allograft is used to reconstruct the coracoclavicular ligament. A nonabsorbable suture is passed through both ends of the allograft. Three strands of nonabsorbable suture are braided together. The tendon and the braided suture are shuttled around the coracoid. At this point, both the braided suture and the allograft tendon enter the anterior portal, wrap around the coracoid base, and exit the anterior portal. A 3-cm incision is made over the distal clavicle. A hole is drilled through the clavicle with a 5-mm drill. A loop of 22-gauge wire is passed through the hole in the clavicle, and a looped suture is shuttled through the hole. A curved clamp is used to create a tunnel from the acromioclavicular joint, under the deltoid, to the anterior portal. The ends of the braided suture and the tendon sutures are grasped by the clamp and pulled out the acromioclavicular joint incision. The limbs of the braided suture and the tendon suture that pass medial to the coracoid are shuttled through the hole in the clavicle using the looped suture that was previously passed through the clavicle. The acromioclavicular joint is reduced by pushing down on the distal clavicle with a bone tamp while simultaneously lifting the acromion upward by superiorly loading the humerus at the elbow. Once the acromioclavicular joint is reduced or slightly over-reduced, the braided suture is tied down securely. The acromioclavicular joint should remain reduced even after the manual reduction maneuver is released. The semitendinosus allograft is tensioned around the distal end of the clavicle and sutured to itself with a nonabsorbable suture. The released coracoacromial ligament is retrieved from the clavicular incision and sutured to the distal clavicle and semitendinosus allograft. The incision is closed in standard fashion, and a sling is applied.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Boyd, James W.; Deters, Katherine A.; Brown, Richard S.
2011-09-01
Reductions in the size of acoustic transmitters implanted in migrating juvenile salmonids have resulted in the use of a shorter incision-one that may warrant only a single suture for closure. However, it is not known whether a single suture will sufficiently hold the incision closed when fish are decompressed and when outward pressure is placed on the surgical site during turbine passage through hydroelectric dams. The objective of this study was to evaluate the effectiveness of single-suture incision closures on five response variables in juvenile Chinook salmon Oncorhynchus tshawytscha that were subjected to simulated turbine passage. An acoustic transmitter (0.43more » g in air) and a passive integrated transponder tag (0.10 g in air) were implanted in each fish; the 6-mm incisions were closed with either one suture or two sutures. After exposure to simulated turbine passage, none of the fish exhibited expulsion of transmitters. In addition, the percentage of fish with suture tearing, incision tearing, or mortal injury did not differ between treatments. Expulsion of viscera through the incision was higher among fish that received one suture (12%) than among fish that received two sutures (1%). The higher incidence of visceral expulsion through single-suture incisions warrants concern. Consequently, for cases in which tagged juvenile salmonidsmay be exposed to turbine passage, we do not recommend the use of one suture to close 6-mm incisions associated with acoustic transmitter implantation.« less
Daniele, Scarponi; Landau, Bernard; Janssen, Ronald; Morgenroth, Holly; Bella, Giano Della
2014-11-12
Bela Leach in Gray is a misapplied and broadly defined genus within the family Mangeliidae Fischer, 1883. Examination of material from the Montagu collection at the Royal Albert Memorial Museum & Art Gallery (RAMM) in Exeter (UK) led to the discovery of six specimens of Murex nebula Montagu 1803 (the type species of Bela). This material is considered to belong to the original lot used by Montagu to define his species. We selected the best-preserved specimen as a lectotype. The lectotype and paralectotypes deposited at the RAMM are fully described and illustrated. Furthermore, diagnostic characters for recognizing B. nebula specimens are presented: protoconch shows weak ornamentation; teleoconch is fusiform with slightly convex whorls characterized by broad, suture-to-suture ribs and dense but weak spiral elements; outer lip is thin; anal sinus is shallow, placed on the shoulder ramp. These key features are of basic importance for: i) restricting the usage of the genus Bela and promoting its stability and consistent usage in literature and ii) separating two allied (and sometimes interchanged) genera: Bela and Mangelia Risso 1826.
Photoactivated methods for enabling cartilage-to-cartilage tissue fixation
NASA Astrophysics Data System (ADS)
Sitterle, Valerie B.; Roberts, David W.
2003-06-01
The present study investigates whether photoactivated attachment of cartilage can provide a viable method for more effective repair of damaged articular surfaces by providing an alternative to sutures, barbs, or fibrin glues for initial fixation. Unlike artificial materials, biological constructs do not possess the initial strength for press-fitting and are instead sutured or pinned in place, typically inducing even more tissue trauma. A possible alternative involves the application of a photosensitive material, which is then photoactivated with a laser source to attach the implant and host tissues together in either a photothermal or photochemical process. The photothermal version of this method shows potential, but has been almost entirely applied to vascularized tissues. Cartilage, however, exhibits several characteristics that produce appreciable differences between applying and refining these techniques when compared to previous efforts involving vascularized tissues. Preliminary investigations involving photochemical photosensitizers based on singlet oxygen and electron transfer mechanisms are discussed, and characterization of the photodynamic effects on bulk collagen gels as a simplified model system using FTIR is performed. Previous efforts using photothermal welding applied to cartilaginous tissues are reviewed.
Arc-to-Arc mini-sling 1999: a critical analysis of concept and technology.
Palma, Paulo
2011-01-01
The aim of this study was to critically review the Arc-to-Arc mini-sling (Palma's technique) a less invasive mid-urethral sling using bovine pericardium as the sling material. The Arc-to-Arc mini-sling, using bovine pericardium, was the first published report of a mini-sling, in 1999. The technique was identical to the "tension-free tape" operation, midline incision and dissection of the urethra. The ATFP (white line) was identified by blunt dissection, and the mini-sling was sutured to the tendinous arc on both sides with 2 polypropylene 00 sutures. The initial results were encouraging, with 9/10 patients cured at the 6 weeks post-operative visit. However, infection and extrusion of the mini-sling resulted in sling extrusion and removal, with 5 patients remaining cured at 12 months. The Arc-to-Arc mini-sling was a good concept, but failed because of the poor technology available at that time. Further research using new materials and better technology has led to new and safer alternatives for the management of stress urinary incontinence.
Brunt, L Michael; Halpin, Valerie J; Klingensmith, Mary E; Tiemann, Debra; Matthews, Brent D; Spitler, Jennifer A; Pierce, Richard A
2008-05-01
Skills training plays an increasing role in residency training. Few medical schools have skills courses for senior students entering surgical residency. A skills course for 4(th)-year medical students matched in a surgical specialty was conducted in 2006 and 2007 during 7 weekly 3-hour sessions. Topics included suturing, knot tying, procedural skills (eg, chest tube insertion), laparoscopic skills, use of energy devices, and on-call management problems. Materials for outside practice were provided. Pre- and postcourse assessment of suturing skills was performed; laparoscopic skills were assessed postcourse using the Society of American Gastrointestinal and Endoscopic Surgeons' Fundamentals of Laparoscopic Surgery program. Students' perceived preparedness for internship was assessed by survey (1 to 5 Likert scale). Data are mean +/- SD and statistical analyses were performed. Thirty-one 4(th)-year students were enrolled. Pre- versus postcourse surveys of 45 domains related to acute patient management and technical and procedural skills indicated an improved perception of preparedness for internship overall (mean pre versus post) for 28 questions (p < 0.05). Students rated course relevance as "highly useful" (4.8 +/- 0.5) and their ability to complete skills as "markedly improved" (4.5 +/- 0.6). Suturing and knot-tying skills showed substantial time improvement pre- versus postcourse for 4 of 5 tasks: simple interrupted suturing (283 +/- 73 versus 243 +/- 52 seconds), subcuticular suturing (385 +/- 132 versus 274 +/- 80 seconds), 1-handed knot tying (73 +/- 33 versus 58 +/- 22 seconds), and tying in a restricted space (54 +/- 18 versus 44 +/- 16 seconds) (p < 0.02). Only 2-handed knot tying did not change substantially (65 +/- 24 versus 59 +/- 24 seconds). Of 13 students who took the Fundamentals of Laparoscopic Surgery skills test, 5 passed all 5 components and 3 passed 4 of 5 components. Skills instruction for senior students entering surgical internship results in a higher perception of preparedness and improved skills performance. Medical schools should consider integrating skills courses into the 4(th)-year curriculum to better prepare students for surgical residency.
The B-Lynch uterine brace suture, and a bit of this and a bit of that...
Karoshi, Mahantesh
2010-03-01
The widespread application of the B-Lynch brace suture to control postpartum hemorrhage has sparked interest in a variety of adjunctive methods, used alone or in combination, to control uterine bleeding. Although the B-Lynch brace suture has been used with good results throughout the world, failures can and do occur in rare instances, especially when the suture is incorrectly placed for use for an inappropriate indication. Four reports of additional methods to control postpartum hemorrhage are published in this issue of IJGO. Three use the B-Lynch brace suture combined with other techniques. The need for additional techniques reminds the reader of the importance of proper suture application for proper indication. Potential reasons for failure of the B-Lynch suture are provided.
Burger, C; Kabir, K; Mueller, M; Rangger, C; Minor, T; Tolba, R H
2006-01-01
In an ovine meniscal repair model, the patellofemoral (PF) osteoarthritis due to a non-sutured tear or failed repair was investigated. A radial meniscus tear was either sutured with polydioxanone (PDS), with a slow degrading polylactide long-term suture(LTS) or left without treatment. Knee joint cartilage in the PF and medial compartment was evaluated compared to normal knees (healthy controls). Retropatellar osteoarthritis in the non-sutured and sutured animals was intense in contrast to the control knees after 6 months in all groups (p < 0.001), and after 12 months in the PDS group (p < 0.001), LTS group and non-sutured animals (p < 0.05). Non-sutured meniscus tears and failed repair lead fast to intense PF osteoarthritis corresponding with tibial damage of the injured compartment.
Tokuhara, Takaya; Nakata, Eiji; Tenjo, Toshiyuki; Kawai, Isao; Kondo, Keisaku; Ueda, Hirofumi; Tomioka, Atsushi
2018-01-01
We report an option for delta-shaped gastroduodenostomy in totally laparoscopic distal gastrectomy (TLDG) for gastric cancer. We detail a single-layer suturing technique for the endoscopic linear stapler entry hole using knotless barbed sutures combined with the application of additional knotted sutures. From June 2013 to February 2017, we performed TLDG with delta-shaped gastroduodenostomy in 20 patients with gastric cancer. The linear stapler was closed and fired to attach the posterior walls of the remnant stomach and the duodenum together. After creating a good view of the greater curvature side of the entry hole for the stapler by retracting the knotted suture on the lesser curvature side toward the ventral side, we performed single-layer entire-thickness continuous suturing of this hole using a 15-cm-long barbed suture running from the greater curvature side to the lesser curvature side. We placed the second and third stitches between the seromuscular layer of the remnant stomach and the entire-thickness layer of the duodenum while suturing the duodenal mucosa as minutely as possible. In addition, we routinely added one or two entire-thickness knotted sutures at the site near the greater curvature side. We placed similar additional knotted sutures at the site with a broad pitch. TLDG with this reconstruction technique was successfully performed in all patients with no occurrences of anastomotic leakage or intraabdominal abscess around the anastomosis. It is suggested that this method can be one option for delta-shaped gastroduodenostomy in TLDG due to its cost-effectiveness and feasibility.
Tokuhara, Takaya; Nakata, Eiji; Tenjo, Toshiyuki; Kawai, Isao; Kondo, Keisaku; Ueda, Hirofumi; Tomioka, Atsushi
2018-01-01
We report an option for delta-shaped gastroduodenostomy in totally laparoscopic distal gastrectomy (TLDG) for gastric cancer. We detail a single-layer suturing technique for the endoscopic linear stapler entry hole using knotless barbed sutures combined with the application of additional knotted sutures. From June 2013 to February 2017, we performed TLDG with delta-shaped gastroduodenostomy in 20 patients with gastric cancer. The linear stapler was closed and fired to attach the posterior walls of the remnant stomach and the duodenum together. After creating a good view of the greater curvature side of the entry hole for the stapler by retracting the knotted suture on the lesser curvature side toward the ventral side, we performed single-layer entire-thickness continuous suturing of this hole using a 15-cm-long barbed suture running from the greater curvature side to the lesser curvature side. We placed the second and third stitches between the seromuscular layer of the remnant stomach and the entire-thickness layer of the duodenum while suturing the duodenal mucosa as minutely as possible. In addition, we routinely added one or two entire-thickness knotted sutures at the site near the greater curvature side. We placed similar additional knotted sutures at the site with a broad pitch. TLDG with this reconstruction technique was successfully performed in all patients with no occurrences of anastomotic leakage or intraabdominal abscess around the anastomosis. It is suggested that this method can be one option for delta-shaped gastroduodenostomy in TLDG due to its cost-effectiveness and feasibility. PMID:29375711
In vitro evaluation of novel antimicrobial coatings for surgical sutures using octenidine.
Obermeier, A; Schneider, J; Föhr, P; Wehner, S; Kühn, K-D; Stemberger, A; Schieker, M; Burgkart, R
2015-09-24
Sutures colonized by bacteria represent a challenge in surgery due to their potential to cause surgical site infections. In order to reduce these type of infections antimicrobially coated surgical sutures are currently under development. In this study, we investigated the antimicrobial drug octenidine as a coating agent for surgical sutures. To achieve high antimicrobial efficacy and required biocompatibility for medical devices, we focused on optimizing octenidine coatings based on fatty acids. For this purpose, antimicrobial sutures were prepared with either octenidine-laurate or octenidine-palmitate at 11, 22, and 33 μg/cm drug concentration normalized per length of sutures. Octenidine containing sutures were compared to the commercial triclosan-coated suture Vicryl® Plus. The release of octenidine into aqueous solution was analyzed and long-term antimicrobial efficacy was assessed via agar diffusion tests using Staphylococcus aureus. For determining biocompatibility, cytotoxicity assays (WST-1) were performed using L-929 mouse fibroblasts. In a 7 days elution experiment, octenidine-palmitate coated sutures demonstrated much slower drug release (11 μg/cm: 7%; 22 μg/cm: 5%; 33 μg/cm: 33%) than octenidine-laurate sutures (11 μg/cm: 82%; 22 μg/cm: 88%; 33 μg/cm: 87%). Furthermore sutures at 11 μg/cm drug content were associated with acceptable cytotoxicity according to ISO 10993-5 standard and showed, similar to Vicryl® Plus, relevant efficacy to inhibit surrounding bacterial growth for up to 9 days. Octenidine coated sutures with a concentration of 11 μg/cm revealed high antimicrobial efficacy and biocompatibility. Due to their delayed release, palmitate carriers should be preferred. Such coatings are candidates for clinical testing in regard to their safety and efficacy.
21 CFR 870.3460 - Endovascular Suturing System.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Endovascular Suturing System. 870.3460 Section 870...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3460 Endovascular Suturing System. (a) Identification. An endovascular suturing system is a medical device intended to provide...
21 CFR 870.3460 - Endovascular Suturing System.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Endovascular Suturing System. 870.3460 Section 870...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3460 Endovascular Suturing System. (a) Identification. An endovascular suturing system is a medical device intended to provide...
21 CFR 870.3460 - Endovascular Suturing System.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Endovascular Suturing System. 870.3460 Section 870...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3460 Endovascular Suturing System. (a) Identification. An endovascular suturing system is a medical device intended to provide...
Ectocranial suture fusion in primates: pattern and phylogeny.
Cray, James; Cooper, Gregory M; Mooney, Mark P; Siegel, Michael I
2014-03-01
Patterns of ectocranial suture fusion among Primates are subject to species-specific variation. In this study, we used Guttman Scaling to compare modal progression of ectocranial suture fusion among Hominidae (Homo, Pan, Gorilla, and Pongo), Hylobates, and Cercopithecidae (Macaca and Papio) groups. Our hypothesis is that suture fusion patterns should reflect their evolutionary relationship. For the lateral-anterior suture sites there appear to be three major patterns of fusion, one shared by Homo-Pan-Gorilla, anterior to posterior; one shared by Pongo and Hylobates, superior to inferior; and one shared by Cercopithecidae, posterior to anterior. For the vault suture pattern, the Hominidae groups reflect the known phylogeny. The data for Hylobates and Cercopithecidae groups is less clear. The vault suture site termination pattern of Papio is similar to that reported for Gorilla and Pongo. Thus, it may be that some suture sites are under larger genetic influence for patterns of fusion, while others are influenced by environmental/biomechanic influences. Copyright © 2013 Wiley Periodicals, Inc.
Sclera-directed knot technique for securing an encircling band in retinal surgery.
Bartov, E; Ginsburg, L H; Ashkenazi, I; Treister, G
1991-10-01
The protruding ends of sutures used to secure the ends of the silicone rubber band placed during many retinal surgical procedures may cause postsurgical irritation, since with presently used suturing techniques, the knot of the suture remains on top of the band, facing the conjunctiva. We describe a suturing technique which, by inverting the band when suturing its ends and then allowing the band to return to its original position, places the knot on the undersurface of the band, against the sclera. Thus, no protruding suture ends are left facing the conjunctiva and the irritation resulting from such a protrusion is averted.
da Rosa, Fernando William Figueiredo; Pohl, Pedro Henrique Isoldi; Mader, Ana Maria Amaral Antônio; de Paiva, Carla Peluso; dos Santos, Aline Amaro; Bianco, Bianca; Rodrigues, Luciano Miller Reis
2015-01-01
ABSTRACT Objective To evaluate inflammatory reaction, fibrosis and neovascularization in dural repairs in Wistar rats using four techniques: simple suture, bovine collagen membrane, silicon mesh and silicon mesh with suture. Methods Thirty Wistar rats were randomized in five groups: the first was the control group, submitted to dural tear only. The others underwent durotomy and simple suture, bovine collagen membrane, silicon mesh and silicon mesh with suture. Animals were euthanized and the spine was submitted to histological evaluation with a score system (ranging from zero to 3) for inflammation, neovascularization and fibrosis. Results Fibrosis was significantly different between simple suture and silicon mesh (p=0.005) and between simple suture and mesh with suture (p=0.015), showing that fibrosis is more intense when a foreign body is used in the repair. Bovine membrane was significantly different from mesh plus suture (p=0.011) regarding vascularization. Inflammation was significantly different between simple suture and bovine collagen membrane. Conclusion Silicon mesh, compared to other commercial products available, is a possible alternative for dural repair. More studies are necessary to confirm these findings. PMID:26761555
Xanthopoulou, Panagiota; Valakos, Efstratios; Youlatos, Dionisios; Nikita, Efthymia
2018-05-01
The present study tests the accuracy of commonly adopted ageing methods based on the morphology of the pubic symphysis, auricular surface and cranial sutures. These methods are examined both in their traditional form as well as in the context of transition analysis using the ADBOU software in a modern Greek documented collection consisting of 140 individuals who lived mainly in the second half of the twentieth century and come from cemeteries in the area of Athens. The auricular surface overall produced the most accurate age estimates in our material, with different methods based on this anatomical area showing varying degrees of success for different age groups. The pubic symphysis produced accurate results primarily for young adults and the same applied to cranial sutures but the latter appeared completely inappropriate for older individuals. The use of transition analysis through the ADBOU software provided less accurate results than the corresponding traditional ageing methods in our sample. Our results are in agreement with those obtained from validation studies based on material from across the world, but certain differences identified with other studies on Greek material highlight the importance of taking into account intra- and inter-population variability in age estimation. Copyright © 2018 Elsevier B.V. All rights reserved.
Britt, Rebecca C; Scerbo, Mark W; Montano, Michael; Kennedy, Rebecca A; Prytz, Erik; Stefanidis, Dimitrios
2015-11-01
A spatial secondary task developed by the authors was used to measure the mental workload of the participant when transferring suturing skills from a box simulator to more realistic surgical conditions using a fresh cadaver. We hypothesized that laparoscopic suturing on genuine bowel would be more challenging than on the Fundamentals of Laparoscopic Surgery (FLS)-simulated bowel as reflected in differences on both suturing and secondary task scores. We trained 14 surgical assistant students to FLS proficiency in intracorporeal suturing. Participants practiced suturing on the FLS box for 30 minutes and then were tested on both the FLS box and the bowel of a fresh cadaver using the spatial, secondary dual-task conditions developed by the authors. Suturing times increased by >333% when moving from the FLS platform to the cadaver F(1,13) = 44.04, P < .001. The increased completion times were accompanied by a 70% decrease in secondary task scores, F(1,13) = 21.21, P < .001. The mental workload associated with intracorporeal suturing increases dramatically when trainees transfer from the FLS platform to human tissue under more realistic conditions of suturing. The increase in mental workload is indexed by both an increase in suturing times and a decrease in the ability to attend to the secondary task. Copyright © 2015 Elsevier Inc. All rights reserved.
Black, Perry
2002-03-01
Cerebrospinal fluid (CSF) leaks are relatively common following spinal surgery. A midline dural tear in the spine is readily repaired by direct application of sutures; however, far-lateral or ventral dural tears are problematic. Fat is an ideal sealant because it is impermeable to water. In this paper the author reports his experience with using fat grafts for the prevention or repair of CSF leaks and proposes a technique in which a large sheet of fat, harvested from the patient's subcutaneous layer, is used to cover not only the dural tear(s) but all of the exposed dura and is tucked into the lateral recess. This procedure prevents CSF from seeping around the fat, which may be tacked to the dura with a few sutures. Fibrin glue is spread on the surface of the fat and is further covered with Surgicel or Gelfoam. For ventral dural tears (associated with procedures in which disc material is excised), fat is packed into the disc space to seal off the ventral dural leak. Dural suture lines following spinal intradural exploration are prophylatically protected from CSF leakage in the same manner. With one exception, 27 dural tears noted during 1650 spinal procedures were successfully repaired using this technique. There was one case of postoperative CSF leakage in 140 cases in which intradural exploration for tumor or other lesions was undertaken. Both postoperative CSF leaks were controlled by applying additional skin sutures. The use of a fat graft is recommended as a rapid, effective means of prevention and repair of CSF leaks following spinal surgery.
De Paolis, P; Mazza, L; Maglione, V; Fronda, G R
2007-06-01
Morgagni-Larrey hernia (MH) is an unusual diaphragmatic hernia of the retrosternal region. Few cases of MH, treated laparoscopically, associated with Down's syndrome (DS) have been reported in literature. On October 2004, a DS 40-year-old male was admitted to our Department with mild abdominal pain and nausea. Hematochemical tests were within the normal range. Ultrasonography showed biliary sludge and multiple gallstones. Chest X-ray revealed a right-sided paracardiac mass that appeared as MH after a thoraco-abdominal computed tomography (CT). Four trocars were placed as a routinary cholecystectomy. Abdominal exploration confirmed the presence of a voluminous hernia through a wide diaphragmatic defect (12 cm) on the left side of the falciform ligament, containing the last 20 cm ileal loops and right colon with the third lateral of transverse. After retrograde cholecystectomy and reduction of the herniated ileo-colonic tract from multiple adherences, the defect was repaired with an interrupted 2/0 silk suture and then a running 2/0 polypropylene suture. Postoperative course was complicated by pulmonary edema but subsequently the patient was discharged without further complications and has no recurrence after 2 years. In conclusion, surgery is necessary for symptomatic MH and to prevent possible severe complications. We preferred laparoscopy for the reduced morbidity compared to laparotomy, even if in our case the postoperative course was not uneventful. There are still few comparative data about the modality of closure of the defect between primary repair with nonabsorbable suture material, in case of small defects, or continuous monofilament suture or prosthesis in case of large defects.
Development of a needle driver with multiple degrees of freedom for neonatal laparoscopic surgery.
Ishimaru, Tetsuya; Takazawa, Shinya; Uchida, Hiroo; Kawashima, Hiroshi; Fujii, Masahiro; Harada, Kanako; Sugita, Naohiko; Mitsuishi, Mamoru; Iwanaka, Tadashi
2013-07-01
The aims of this study were to develop a thin needle driver with multiple degrees of freedom and to evaluate its efficacy in multidirectional suturing compared with a conventional needle driver. The tip (15 mm) of the novel user-friendly needle driver (3.5 mm in diameter) has three degrees of freedom for grasping, rotation, and deflection. Six pediatric surgeons performed two kinds of suturing tasks in a dry box: three stitches in continuous suturing that were perpendicular or parallel to the insertion direction of the instrument, first using the novel instrument, then using a conventional instrument, and finally using the novel instrument again. The accuracy of insertion and exit compared with the target points and the procedure time were measured. In the conventional and novel procedures the mean gaps from the insertion point to the target in perpendicular suturing were 0.8 mm and 0.7 mm, respectively; in parallel suturing they were 0.8 mm and 0.6 mm, respectively. The mean gaps from the exit point to the target in perpendicular suturing were 0.6 mm and 0.6 mm for conventional and novel procedures, respectively; in parallel suturing they were 0.6 mm and 0.8 mm, respectively. The procedure time for perpendicular suturing was 33 seconds and 64 seconds for conventional and novel procedures, respectively (P=.02); for parallel suturing it was 114 seconds and 91 seconds, respectively. Our novel needle driver maintained accuracy of suturing; parallel suturing with the novel driver may be easier than with the conventional one.
Strain in the Braincase and Its Sutures During Function
Herring, Susan W.; Teng, Shengyi
2010-01-01
The skull is distinguished from other parts of the skeleton by its composite construction. The sutures between bony elements provide for interstitial growth of the cranium, but at the same time they alter the transmission of stress and strain through the skull. Strain gages were bonded to the frontal and parietal bones of miniature pigs and across the interfrontal, interparietal and coronal sutures. Strains were recorded 1) during natural mastication in conjunction with electromyographic activity from the jaw muscles and 2) during stimulation of various cranial muscles in anesthetized animals. Vault sutures exhibited vastly higher strains than did the adjoining bones. Further, bone strain primarily reflected torsion of the braincase set up by asymmetrical muscle contraction; the tensile axis alternated between +45° and −45° depending on which diagonal masseter/temporalis pair was most active. However, suture strains were not related to overall torsion but instead were responses to local muscle actions. Only the coronal suture showed significant strain (tension) during jaw opening; this was caused by the contraction of neck muscles. All sutures showed strain during jaw closing, but polarity depended on the pattern of muscle usage. For example, masseter contraction tensed the coronal suture and the anterior part of the interfrontal suture, whereas the temporalis caused compression in these locations. Peak tensile strains were larger than peak compressive strains. Histology suggested that the skull is bent at the sutures, with the ectocranial surface tensed and the endocranial surface predominantly compressed. Collectively, these results indicate that skulls with patent sutures should be analyzed as complexes of independent parts rather than solid structures. PMID:10918130
Sequential selective same-day suture removal in the management of post-keratoplasty astigmatism
Fares, U; Mokashi, A A; Elalfy, M S; Dua, H S
2013-01-01
Aims In a previous study, we proposed that corneal topography performed 30–40 min after the initial suture removal can identify the next set of sutures requiring removal, for the treatment of post-keratoplasty astigmatism. The aim of this study was to evaluate the effect of removing subsequent sets of sutures at the same sitting. Methods 10/0 nylon interrupted sutures were placed, to secure the graft–host junction, at the time of keratoplasty. Topography was performed using Pentacam (Oculus) before suture removal. The sutures to be removed in the steep semi-meridians were identified and removed at the slit-lamp biomicroscope. Topography was repeated 30–40 min post suture removal, the new steep semi-meridians determined, and the next set of sutures to be removed were identified and removed accordingly. Topography was repeated 4–6 weeks later and the magnitude of topographic astigmatism was recorded. A paired-samples t-test was used to evaluate the impact of selective suture removal on reducing the magnitude of topographic and refractive astigmatism. Results Twenty eyes of 20 patients underwent sequential selective same-day suture removal (SSSS) after corneal transplantation. This study showed that the topographic astigmatism decreased by about 46.7% (3.68 D) and the refractive astigmatism decreased by about 37.7% (2.61 D) following SSSS. Vector calculations also show a significant reduction of both topographic and refractive astigmatism (P<0.001). Conclusion SSSS may help patients to achieve satisfactory vision more quickly and reduce the number of follow-up visits required post keratoplasty. PMID:23743526
Singh, Ashima; Bartsch, Sarah M; Muder, Robert R; Lee, Bruce Y
2014-08-01
While the persistence of high surgical site infection (SSI) rates has prompted the advent of more expensive sutures that are coated with antimicrobial agents to prevent SSIs, the economic value of such sutures has yet to be determined. Using TreeAge Pro, we developed a decision analytic model to determine the cost-effectiveness of using antimicrobial sutures in abdominal incisions from the hospital, third-party payer, and societal perspectives. Sensitivity analyses systematically varied the risk of developing an SSI (range, 5%-20%), the cost of triclosan-coated sutures (range, $5-$25/inch), and triclosan-coated suture efficacy in preventing infection (range, 5%-50%) to highlight the range of costs associated with using such sutures. Triclosan-coated sutures saved $4,109-$13,975 (hospital perspective), $4,133-$14,297 (third-party payer perspective), and $40,127-$53,244 (societal perspective) per SSI prevented, when a surgery had a 15% SSI risk, depending on their efficacy. If the SSI risk was no more than 5% and the efficacy in preventing SSIs was no more than 10%, triclosan-coated sutures resulted in extra expenditure for hospitals and third-party payers (resulting in extra costs of $1,626 and $1,071 per SSI prevented for hospitals and third-party payers, respectively; SSI risk, 5%; efficacy, 10%). Our results suggest that switching to triclosan-coated sutures from the uncoated sutures can both prevent SSIs and save substantial costs for hospitals, third-party payers, and society, as long as efficacy in preventing SSIs is at least 10% and SSI risk is at least 10%.
Shi, Brendan Y; Diaz, Miguel; Belkoff, Stephen M; Srikumaran, Uma
2017-12-01
Obtaining strong fixation in low-density bone is increasingly critical in surgical repair of rotator cuff tears because of the aging population. To evaluate two new methods of improving pullout strength of transosseous rotator cuff repair in low-density bone, we analyzed the effects of 1) using 2-mm suture tape instead of no. 2 suture and 2) augmenting the lateral tunnel with cement. Eleven pairs of osteopenic or osteoporotic cadaveric humeri were identified by dual-energy x-ray absorptiometry. One bone tunnel and one suture were placed in the heads of 22 specimens. Five randomly selected pairs were repaired with no. 2 suture; the other six pairs were repaired with 2-mm suture tape. One side of each pair received lateral tunnel cement augmentation. Specimens were tested to suture pullout. Data were fitted to multivariate models that accounted for bone mineral density and other specimen characteristics. Two specimens were excluded because of knot-slipping during testing. Use of suture tape versus no. 2 suture conferred a 75-N increase (95% CI: 37, 113) in pullout strength (P<0.001). Cement augmentation conferred a 42-N improvement (95% CI: 10, 75; P=0.011). Other significant predictors of pullout strength were age, sex, and bone mineral density. We show two methods of improving the fixation strength of transosseous rotator cuff repairs in low-density bone: using 2-mm suture tape instead of no. 2 suture and augmenting the lateral tunnel with cement. These methods may improve the feasibility of transosseous repairs in an aging patient population. Copyright © 2017 Elsevier Ltd. All rights reserved.
Comparing the Tolerability of a Novel Wound Closure Device Using a Porcine Wound Model
Townsend, Katy L.; Akeroyd, Jen; Russell, Duncan S.; Kruzic, Jamie J.; Robertson, Bria L.; Lear, William
2018-01-01
Objective: To compare the tolerability and mechanical tensile strength of acute skin wounds closed with nylon suture plus a novel suture bridge device (SBD) with acute skin wounds closed with nylon suture in a porcine model. Approach: Four Yucatan pigs each received 12 4.5 cm full-thickness incisions that were closed with 1 of 4 options: Suture bridge with nylon, suture bridge with nylon and subdermal polyglactin, nylon simple interrupted, and nylon simple interrupted with subdermal polyglactin. Epithelial reaction, inflammation, and scarring were examined histologically at days 10 and 42. Wound strength was examined mechanically at days 10 and 42 on ex vivo wounds from euthanized pigs. Results: Histopathology in the suture entry/exit planes showed greater dermal inflammation with a simple interrupted nylon suture retained for 42 days compared with the SBD retained for 42 days (p < 0.03). While tensile wound strength in the device and suture groups were similar at day 10, wounds closed with the devices were nearly 8 times stronger at day 42 compared with day 10 (p < 0.001). Innovation: A novel SBD optimized for cutaneous wound closure that protects the skin surface from suture strands, forms a protective bridge over the healing wound edges, and knotlessly clamps sutures. Conclusion: This study suggests that the use of a SBD increases the tolerability of nylon sutures in porcine acute skin wound closures allowing for prolonged mechanical support of the wound. For slow healing wounds, this may prevent skin wound disruption, such as edge necrosis and dehiscence. PMID:29892494
Sequential selective same-day suture removal in the management of post-keratoplasty astigmatism.
Fares, U; Mokashi, A A; Elalfy, M S; Dua, H S
2013-09-01
In a previous study, we proposed that corneal topography performed 30-40 min after the initial suture removal can identify the next set of sutures requiring removal, for the treatment of post-keratoplasty astigmatism. The aim of this study was to evaluate the effect of removing subsequent sets of sutures at the same sitting. 10/0 nylon interrupted sutures were placed, to secure the graft-host junction, at the time of keratoplasty. Topography was performed using Pentacam (Oculus) before suture removal. The sutures to be removed in the steep semi-meridians were identified and removed at the slit-lamp biomicroscope. Topography was repeated 30-40 min post suture removal, the new steep semi-meridians determined, and the next set of sutures to be removed were identified and removed accordingly. Topography was repeated 4-6 weeks later and the magnitude of topographic astigmatism was recorded. A paired-samples t-test was used to evaluate the impact of selective suture removal on reducing the magnitude of topographic and refractive astigmatism. Twenty eyes of 20 patients underwent sequential selective same-day suture removal (SSSS) after corneal transplantation. This study showed that the topographic astigmatism decreased by about 46.7% (3.68 D) and the refractive astigmatism decreased by about 37.7% (2.61 D) following SSSS. Vector calculations also show a significant reduction of both topographic and refractive astigmatism (P<0.001). SSSS may help patients to achieve satisfactory vision more quickly and reduce the number of follow-up visits required post keratoplasty.
21 CFR 878.4830 - Absorbable surgical gut suture.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Absorbable surgical gut suture. 878.4830 Section 878.4830 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... surgical gut suture. (a) Identification. An absorbable surgical gut suture, both plain and chromic, is an...
Garlipp, B; Schulz, H-U; Böttcher, S; Lemke, A; Meyer, F; Lippert, H
2012-11-01
Obstruction of bile flow following pancreatoduodenectomy can be caused by stenosis of the hepaticojejunostomy created at the time of surgery, obstruction of the bile-draining jejunal loop, stones or, very rarely, ingested foreign bodies in the common hepatic duct. In analogy with endoscopic sphincterotomy or the once popular side-to-side-choledochduodenostomy, the creation of a hepaticojejunostomy eliminates the barrier of the sphincter Oddi, enabling intestinal content such as ingested foreign bodies or food fibers to migrate into the bile duct. We report on the case of a patient developing biliary tract obstruction due to fibrous material in the common hepatic duct 15 years after pancreatoduodenectomy. In addition, an overview of the literature on the rare phenomenon of foreign body-associated obstructive jaundice is given. © Georg Thieme Verlag KG Stuttgart · New York.
Free-Standing Biodegradable Poly(lactic acid) Nanosheet for Sealing Operations in Surgery.
Okamura, Yosuke; Kabata, Koki; Kinoshita, Manabu; Saitoh, Daizoh; Takeoka, Shinji
2009-11-20
A free-standing biodegradable nanosheet composed of poly(L-lactic acid) (PLLA) was shown to have excellent sealing efficacy for a gastric incision as a novel wound dressing material that did not require adhesive agents, and the PLLA nanosheet-induced wound repair showed neither scars nor tissue adhesion. This material may, therefore, be an ideal alternative to conventional tissue repairing procedures using suture/ligation in surgery. Copyright © 2009 WILEY‐VCH Verlag GmbH & Co. KGaA, Weinheim.
Cystoscopic suture removal by Holmium-YAG laser after Burch procedure
Karaşahin, Emre Kazım; Esin, Sertaç; Alanbay, İbrahim; Ercan, Mutlu Cihangir; Mutlu, Erol; Başer, İskender; Basal, Şeref
2011-01-01
Burch colposuspension remains one of the successful operations performed for stress incontinence. Accidental suturing of the bladder wall during the procedure or subsequent erosion may lead to lower urinary tract symptoms. Diagnosis and management of these sutures indicate precise evaluation for which a 70 degree cystoscope is used. In selected cases, Holmium-YAG laser may enable us to manage long-standing, encrustated neglected sutures. Here we would like to report successful removal of intravesical sutures using the Holmium-YAG laser. PMID:24591960
Ripcord adjustable suture technique for use in strabismus surgery.
Coats, D K
2001-09-01
Adjustable sutures in strabismus surgery may be difficult or impossible in poorly cooperative patients. An adjunct suture technique that allows a 1-step, all-or-nothing, preprogrammed adjustment in patients not considered good candidates for standard postoperative adjustable sutures is described. Twelve patients underwent adjustable strabismus surgery using the ripcord technique. Six patients had unacceptable alignment after surgery. In 5 of these, alignment was successfully adjusted. The ripcord adjustable suture technique is effective and is well tolerated by patients.
The suspension (Frost) suture: experience and applications.
Connolly, Karen L; Albertini, John G; Miller, Christopher J; Ozog, David M
2015-03-01
The Frost suture is a well-known surgical technique for providing upward tension on the lower lid to prevent or correct ectropion after surgical interventions in the periorbital area. Despite its relatively common use, comprehensive information on executing this technique is not readily available. To review eyelid anatomy, indications, and proper technique for performing the Frost suture, as well as potential complications. A review of the literature on Frost sutures was performed. Cadaveric dissection was performed to demonstrate placement of the Frost suture. The Frost suture is a useful method to reduce the risk of ectropion after surgery near the lower eyelid. Downward pull on the lid can occur with normal wound contracture even if ectropion is not present with the initial repair, reinforcing the need for preventive measures. Potential complications of this technique include superficial skin erosion of the upper lid, corneal abrasion, and blockage of the field of vision while the suture is in place.
Werthel, Jean-David; Pelissier, Alexandre; Massin, Philippe; Boyer, Patrick; Valenti, Philippe
2014-10-01
The double row cuff repair with suture bridging is commonly used for arthroscopic rotator cuff repair (RCR). Despite its biomechanical qualities, the rate of iterative tears with this technique is important. The aim of our study was to evaluate the effect of autologous conditioned plasma (ACP) on functional results and on the rate of iterative tears after RCR by suture bridging. A consecutive series of 65 patients who underwent arthroscopic double-row suture bridge (Speed-Bridge, Arthrex) primary cuff repair of symptomatic full-thickness supraspinatus tear (retraction <3 in the Patte classification) were evaluated. Mean patient age was 60 (+/-8). The supraspinatus was repaired by knot-less bridging (SwiveLock, Arthrex) with suture tape material. 2 homogenous groups were created (A: 33 patients, B: 32 patients). In group A, all patients received, besides the cuff repair, an intra-tendinous ACP injection. Constant scores and Simple Shoulder Tests (SST) were measured pre-operatively and after a minimum follow-up period of 12 months post-operatively. Structural integrity of the repairs was evaluated by MRI according to the Sugaya classification. Sugaya >4 were considered as iterative tears. Mean follow-up was 19 months (+/-42) in the 2 groups. The mean quantity of ACP injected was 6ml. (+/-1.5) and no specific complication of the injection was found. Mean preoperative Constant-Murley scores were 41,2 (±7,7) and 38 (±11)in group B. Mean normalized Constant-Murley score increased from 41 points (±7) pre-operatively to 70 points (±8) post-operatively in group A and from 38 points (±11) to 73 points (±11) in group B. There were no significative differences between the two groups (P > 0.05). In group A, 31 repairs were Sugaya 1-3 (94%), vs. 30 in group B (93%), and 1 was type 4 in group A (5%) vs. 2 in group B (8%). In both groups, RCR with suture bridging gave successful functional outcomes, with a low rate of iterative tear. In this preliminary study, the adjuvant effect of ACP injections could not be showed on both functional and structural results. Longer follow-up is needed to evaluate potential differences.
Poe, Demelza J
2011-01-01
A fused/closed basilar suture is usually treated as an indication of old age in great apes. A sample, drawn from a variety of sources, of known-aged captive great ape skeletons was analyzed to test the usefulness of using the basilar suture to categorize adult skeletons as either "adult" or "old adult". The state of closure of the basilar suture was examined in 30 chimpanzees, 19 gorillas, and 15 orangutans, all of known age. The results show that the basilar suture demonstrates a high level of uniformity in rate of closure and is closed at an early age in virtually all known-aged individuals. Thus, an old adult category most likely includes individuals who are, in fact, relatively young. This indicates that using the basilar suture as a means to classify individual skeletons as adult or old adult is very imprecise. The homogenous nature of basilar suture closure appears to prevent meaningful application of suture status for categorizing adult ape skeletons by age groups.
3D Printed Anchoring Sutures for Permanent Shaping of Tissues.
Wei, Wei; Li, Yuxiao; Yang, Huazhe; Nassab, Reza; Shahriyari, Fatemeh; Akpek, Ali; Guan, Xiaofei; Liu, Yanhui; Taranejoo, Shahrouz; Tamayol, Ali; Zhang, Yu Shrike; Khademhosseini, Ali; Jang, Hae Lin
2017-12-01
Sutures are one of the most widely used devices for adhering separated tissues after injury or surgery. However, most sutures require knotting, which can create a risk of inflammation, and can act as mechanically weak points that often result in breakage and slipping. Here, an anchoring suture is presented with a design that facilitates its propagation parallel to the suturing direction, while maximizing its resistive force against the opposite direction of external force to lock its position in tissues. Different microstructures of suture anchors are systematically designed using orthogonal arrays, and selected based on shape factors associated with mechanical strength. 3D printing is used to fabricate different types of hollow microstructured suture anchors, and optimize their structure for the effective shaping of tissues. To define the structural design for fixing tissues, the maximum force required to pull 3D printed anchors in different directions is examined with tissues. The tissue reshaping function of suture anchors is further simulated ex vivo by using swine ear, nose, and skin, and bovine muscle tendon. This study provides advantages for building functional sutures that can be used for permanently reshaping tissues with enhanced mechanical strength, eliminating the need for knotting to improve surgical efficiency. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liss, S. A.; Ashton, N. K.; Brown, R. S.
A new acoustic transmitter (AT; cylindrical, 0.7 g in air, 24.2×5.0 mm, up to 365 d battery life) was developed to monitor age-0 sturgeon; however, an implantation technique is critical to provide guidance for its use in field research. The goal of this study was to evaluate four implantation techniques by assessing transmitter retention, survival, growth, and wound healing variables. White sturgeon (Acipenser transmontanus; n = 150, 35–116 g, 182–289 mm fork length) were separated into five treatments: 1) unmarked, 2) flank incision with one suture, 3) flank incision without a suture, 4) offline incision with one suture, and 5)more » offline incision without a suture. Tagged fish were implanted with a non-functioning AT and all fish were held for 28 days. There was 100% transmitter retention and no difference in survival or growth (by 14 d post-implantation) among treatments. Sutured treatments had greater inflammation and presence of ulceration and water mold than non-sutured. Offline incision fish were more susceptible to red vein aggregation than flank incision fish. Non-sutured treatments had greater openness than sutured, but only during the first 14 d post-implantation. The flank incision without a suture technique is recommended.« less
Johnson, Amy S; Ellers, Olaf; Lemire, Jim; Minor, Melissa; Leddy, Holly A
2002-02-07
The shape of sea urchins may be determined mechanically by patterns of force analogous to those that determine the shape of a water droplet. This mechanical analogy implies skeletal flexibility at the time of growth. Although comprised of many rigid calcite plates, sutural collagenous ligaments could confer such flexibility if the sutures between plates loosened and acted as joints at the time of growth. We present experimental evidence of such flexibility associated with weight gain and growth. Over 13-, 4-, and 2-week periods, fed urchins (Strongylocentrotus droebachiensis) gained weight and developed looser sutures than unfed urchins that maintained or lost weight. Further, skeletons of fed urchins force-relaxed more than did those of unfed urchins and urchins with loose sutures force-relaxed more than those with tight sutures. Urchins (Strongylocentrotus franciscanus) fed for two and a half weeks, gained weight, also had looser skeletons and deposited calcite at sutural margins, whereas unfed ones did not. In field populations of S. droebachiensis the percentage having loose sutures varied with urchin diameter and reflected their size-specific growth rate. The association between feeding, weight gain, calcite deposition, force relaxation and sutural looseness supports the hypothesis that urchins deform flexibly while growing, thus determining their drop-like shapes.
Heterochrony and patterns of cranial suture closure in hystricognath rodents
Wilson, Laura A B; Sánchez-Villagra, Marcelo R
2009-01-01
Sutures, joints that allow one bone to articulate with another through intervening fibrous connective tissue, serve as major sites of bone expansion during postnatal craniofacial growth in the vertebrate skull and represent an aspect of cranial ontogeny which may exhibit functional and phylogenetic correlates. Suture evolution among hystricognath rodents, an ecologically diverse group represented here by 26 species, is examined using sequence heterochrony methods, i.e. event pairing and parsimov. Although minor nuances in suture closure sequence exist between species, the overall sequence was found to be conserved both across the hystricognath group and, to an increasing degree, within selected clades. At species level, suture closure pattern exhibited a significant positive correlation with patterns previously reported for hominoids. Patterns for most clades revealed the first sutures to close are those contacting the exoccipital, interparietal, and palatine bones. Heterochronic shifts were found along 19 of 35 branches within the hystricognath phylogeny. The number of shifts per node ranged from one to seven events and, overall, involved 21 of 34 suture sites. The topology generated by parsimony analyses of the event pair matrix yielded only one grouping that was congruent with the evolutionary relationships, compiled from morphological and molecular studies, taken as framework. Sutures contacting the exoccipital displayed the highest levels of most complete closure across all species. Level of suture closure is negatively correlated with cranial length (P < 0.05). Differing life history and locomotory strategies are coupled in part with differing suture closure patterns among several species. PMID:19245501
Microbiology of Explanted Suture Segments from Infected and Noninfected Surgical Patients
Krepel, Candace J.; Marks, Richard M.; Rossi, Peter J.; Sanger, James; Goldblatt, Matthew; Graham, Mary Beth; Rothenburger, Stephen; Collier, John; Seabrook, Gary R.
2013-01-01
Sutures under selective host/environmental factors can potentiate postoperative surgical site infection (SSI). The present investigation characterized microbial recovery and biofilm formation from explanted absorbable (AB) and nonabsorbable (NAB) sutures from infected and noninfected sites. AB and NAB sutures were harvested from noninfected (70.9%) and infected (29.1%) sites in 158 patients. At explantation, devices were sonicated and processed for qualitative/quantitative bacteriology; selective sutures were processed for scanning electron microscopy (SEM). Bacteria were recovered from 85 (53.8%) explanted sites; 39 sites were noninfected, and 46 were infected. Suture recovery ranged from 11.1 to 574.6 days postinsertion. A significant difference in mean microbial recovery between noninfected (1.2 isolates) and infected (2.7 isolates) devices (P < 0.05) was noted. Staphylococcus epidermidis, Staphylococcus aureus, coagulase-negative staphylococci (CNS), Peptostreptococcus spp., Bacteroides fragilis, Escherichia coli, Enterococcus spp., Pseudomonas aeruginosa, and Serratia spp. were recovered from infected devices, while commensal skin flora was recovered from noninfected devices. No significant difference in quantitative microbial recovery between infected monofilament and multifilament sutures was noted. Biofilm was present in 100% and 66.6% of infected and noninfected devices, respectively (P < 0.042). We conclude that both monofilament and braided sutures provide a hospitable surface for microbial adherence: (i) a significant difference in microbial recovery from infected and noninfected sutures was noted, (ii) infected sutures harbored a mixed flora, including multidrug-resistant health care-associated pathogens, and (iii) a significant difference in the presence or absence of a biofilm in infected versus noninfected explanted devices was noted. Further studies to document the benefit of focused risk reduction strategies to minimize suture contamination and biofilm formation postimplantation are warranted. PMID:23175247
Guo, Jiao; Pan, Ling-Hui; Li, Yun-Xi; Yang, Xiang-Di; Li, Le-Qun; Zhang, Chun-Yan; Zhong, Jian-Hong
2016-03-01
Surgical site infection (SSI) is the third most frequent type of nosocomial infections. Triclosan-coated sutures are often used to reduce the risk of SSI, but studies examining this have given conflicting results. Therefore, this meta-analysis was performed to assess the efficacy of triclosan-coated sutures for reducing risk of SSI in adults. PubMed, EMBASE, Google Scholar, and ClinicalTrials.gov were searched to identify randomized clinical trials evaluating triclosan-coated sutures for preventing SSI on patients 18 y or older. Thirteen randomized clinical trials involving 5256 participants were included. Triclosan-coated sutures were associated with lower risk of SSI than uncoated sutures across all surgeries (risk ratio [RR] 0.76, 95% confidence interval [CI] 0.65-0.88, P < 0.001). Similar proportions of patients experienced wound dehiscence with either type of suture (RR 0.97, 95% CI 0.49-1.89, P = 0.92). Subgroup analysis showed lower risk of SSI with triclosan-coated sutures in abdominal surgeries (RR 0.70, 95% CI 0.50-0.99, P = 0.04) and group with prophylactic antibiotic (RR 0.79, 95% CI 0.63-0.99, P = 0.04). However, such risk reduction was not observed in cardiac surgeries, breast surgeries, or group without prophylactic antibiotic. Triclosan-coated sutures can decrease the incidence of SSI in abdominal surgeries and might not interfere with wound healing process. Nevertheless, further studies are needed to examine whether triclosan-coated sutures are effective at preventing SSI in non-abdominal surgeries and to further study the interaction of antibiotic prophylaxis with triclosan-coated sutures. Copyright © 2016 Elsevier Inc. All rights reserved.
Renko, Marjo; Paalanne, Niko; Tapiainen, Terhi; Hinkkainen, Matti; Pokka, Tytti; Kinnula, Sohvi; Sinikumpu, Juha-Jaakko; Uhari, Matti; Serlo, Willy
2017-01-01
Surgical site infections (SSIs) are a pervasive problem in surgery. Sutures coated or impregnated with triclosan might reduce the occurrence of SSIs, but evidence of their efficacy is limited, especially in children. We designed a randomised, double-blind, controlled trial in patients who underwent elective or daytime emergency surgery at Oulu University Hospital (Oulu, Finland). We included children younger than 18 years staying in the paediatric surgery and orthopaedics ward for any elective or emergency surgery during the daytime and with anticipated use of absorbing sutures. Children were randomly allocated (1:1) to receive either triclosan-containing sutures or ordinary absorbing sutures. The primary outcome was the occurrence of superficial or deep surgical site infections according to the Centers for Disease Control and Prevention criteria within 30 days after surgery. The primary analysis was with modified intention to treat. This trial is registered at ClinicalTrials.gov, number NCT01220700. Between September, 2010, and December, 2014, 1633 children were recruited. In the modified intention-to-treat group, SSIs occurred in 20 (3%) of 778 patients allocated to receive triclosan-containing sutures and in 42 (5%) of 779 patients allocated to receive control sutures (risk ratio 0·48, 95% CI 0·28-0·80). To prevent one SSI, triclosan-containing sutures had to be used in 36 children (95% CI 21-111). One patient died from suspected mitochondrial disease; no other expected or unexpected adverse events were reported in either of the groups. Use of triclosan-containing sutures effectively reduced the occurrence of all SSIs compared with normal sutures. The results accord with the results of meta-analyses of previous studies in adults. Use of triclosan-containing sutures is a simple way to reduce SSIs in children. The Alma and K A Snellman Foundation. Copyright © 2017 Elsevier Ltd. All rights reserved.
Waldrop, Norman E; Wijdicks, Coen A; Jansson, Kyle S; LaPrade, Robert F; Clanton, Thomas O
2012-11-01
Despite the popularity of the Broström procedure for secondary repair of chronic lateral ankle instability, there have been no biomechanical studies reporting on the strength of this secondary repair method, whether using suture fixation or suture anchors. The purpose of our study was to perform a biomechanical comparison of the ultimate load to failure and stiffness of the traditional Broström technique using only a suture repair compared with a suture anchor repair of the anterior talofibular ligament (ATFL) at time zero. We believed that fixation strength of the suture anchor repair would be closer to the strength of the native ligament and allow more aggressive rehabilitation. Controlled laboratory study. Twenty-four fresh-frozen cadaveric ankles were randomly divided into 4 groups of 6 specimens. One group was an intact control group, and the other groups consisted of the traditional Broström and 2 suture anchor modifications (suture anchors in talus or fibula) of the Broström procedure. The specimens were loaded to failure to determine the strength and stiffness of each construct. In load-to-failure testing, ultimate failure loads of the Broström (68.2 ± 27.8 N; P = .013), suture anchor fibula (79.2 ± 34.3 N; P = .037), and suture anchor talus (75.3 ± 45.6 N; P = .027) repairs were significantly lower than that of the intact (160.9 ± 72.2 N) ATFL group. Stiffness of the Broström (6.0 ± 2.5 N/mm; P = .02), suture anchor fibula (6.8 N/mm ± 2.7; P = .05), and suture anchor talus (6.6 N/mm ± 4.0; P = .04) repairs were significantly lower than that of the intact (12.4 N/mm ± 4.1 N/mm) ATFL group. The 3 repair groups were not significantly different from each other, but all 3 were substantially lower in strength and stiffness when compared to the intact ATFL. The use of suture anchors to repair the ATFL produces a repair that can withstand loads to failure similar to the suture-only Broström repair. However, all 3 repair groups were much weaker than the intact, uninjured ATFL. Biomechanically, the results show that both suture anchor and direct suture repair of the ATFL provide similar strength and stiffness. Unfortunately, these methods provide less than half the strength and stiffness of the native ATFL at time zero. As a result, regardless of the repair method, it is necessary to sufficiently protect the repair to avoid premature failure.
Zhao, Jie; Liu, Zhixiong; Liu, Yunsheng; Liu, Jinfang; Fang, Wenhua; Rao, Yihua; Yang, Liang; Yuan, Xianrui
2010-03-01
To evaluate the efficacy of dural tenting suture and epidural drainage in craniotomy. In 145 cases of intracranial lesions, dural tenting suture and epidural drainage were performed to prevent epidural hematoma. Postoperative computed tomography (CT) showed no epidural hematoma required surgery in both groups. Both dural tenting suture and epidural drainage are effective in preventing epidural hematoma. Hemostasis is the key step. Dural tenting suture without epidural drainage relieves psychological stress. It decreases the risk of intracranial infection and avoids some unusual complications.
Krishnan, R; Izadi, S; Morton, C E; Marsh, I B
2007-07-01
Frost sutures are temporary suspension sutures conventionally used in oculoplastics. The case is presented here of a patient with multiple orbital fractures who developed worsening conjunctival chemosis and pseudoproptosis. This patient was managed successfully with Frost sutures. To the best of the authors' knowledge, there is no documented use of Frost sutures in this type of case. It is emphasized that this technique should only be considered following rigorous exclusion of retrobulbar pathology and careful attention towards early detection of raised intraocular pressure.
Fujii, Masataka; Furumatsu, Takayuki; Kodama, Yuya; Miyazawa, Shinichi; Hino, Tomohito; Kamatsuki, Yusuke; Yamada, Kazuki; Ozaki, Toshifumi
2017-05-01
Medial meniscus posterior root has an important role in the maintenance of knee articular cartilage. Although pullout repair of the medial meniscus posterior root tear has become a gold standard, it has several difficulties for suturing. We have developed a modified Mason-Allen suture technique using the FasT-Fix all-inside suture device combined with Ultrabraid. The present suture technique allows a strong grasping of the medial meniscus posterior horn for arthroscopic pullout repair.
Mesa, M.G.; Magie, R.J.; Copeland, E.S.; Christiansen, H.E.
2011-01-01
Radio-tagged adult Pacific lamprey Entosphenus tridentatus held in a raceway with Plexiglas-lined walls and bottom healed more slowly and retained sutures longer than fish held in an all-concrete raceway or one with Plexiglas walls and a cobble-lined bottom. On all substrata, healing depended on when sutures were lost, and fish that lost their sutures in <14 days post-surgery healed faster than those that kept sutures longer. Long-term suture retention led to tissue trauma, infection and poor survival.
Post thyroidectomy suture granuloma: a cytological diagnosis.
Javalgi, Anita P; Arakeri, Surekha U
2013-04-01
There are known post thyroidectomized complications, a suture granuloma being less frequent, with its late complication mimicking recurrent thyroid cancer. A suture granuloma is a benign, granulomatous inflammatory reaction that occurs due to the use of non absorbable suture. It constitutes one of the late complications which altogether make up less than 2% of its incidence. A suture granuloma is similar to a foreign body reaction and it usually develops slowly as a painless, palpable asymptomatic mass over the years. It mimics a cancer recurrence or a lymph node metastasis. Here, we are reporting a case of a post thyroidectomy suture granuloma in a 46 years old lady who presented with a painless swelling in the lateral neck, with a past history of thyroidectomy 5 years back.
Method and apparatus for producing a thermal atomic oxygen beam
NASA Technical Reports Server (NTRS)
Banks, Bruce A. (Inventor); Rutledge, Sharon K. (Inventor)
1994-01-01
Atomic oxygen atoms are routed to a material through a sufficiently tortuous path so that vacuum ultraviolet radiation is obstructed from arriving at the surface of the material. However, the material surface continues to be exposed to the atomic oxygen.
Mykhalchuk, Vasyl M; Vasyliev, Averian G
2018-01-01
Introduction: Out of all respiratory diseases COPD is the leading cause of death and is characterized with diffuse non-reversible airway obstruction. Many various components play role in development and progression of this disease, while COPD risk factors play the most prominent role. Further progress in healthcare system development around COPD in Ukraine requires analysis of legislation, regulating pulmonological medical service in Ukraine. The aim: To analyze the influence of major risk factors on the development of chronic obstructive pulmonary disease and to determine key legislative aspects of the organization of medical care for COPD patients in Ukraine. Materials and methods: 50 medical literature sources were systematically reviewed as the material for the research of COPD risk factors and their impact on studies disease. Also, an analysis of existing legislative acts regulating the pulmonological medical care in Ukraine, specifically, in patients with COPD, was conducted. Conclusions: There is a need to develop and implement a set of organizational and medical measures aiming at addressing the priorities of public healthcare, and specifically improvement of the quality of medical care for patients with chronic obstructive pulmonary disease in Ukraine.
30 CFR 75.1311 - Transporting explosives and detonators.
Code of Federal Regulations, 2012 CFR
2012-07-01
... material, with no metal or other conductive materials exposed inside, except as specified in paragraph (d... the mine roof or other obstruction; (3) Except when persons are riding the belt to accompany...
30 CFR 75.1311 - Transporting explosives and detonators.
Code of Federal Regulations, 2014 CFR
2014-07-01
... material, with no metal or other conductive materials exposed inside, except as specified in paragraph (d... the mine roof or other obstruction; (3) Except when persons are riding the belt to accompany...
30 CFR 75.1311 - Transporting explosives and detonators.
Code of Federal Regulations, 2013 CFR
2013-07-01
... material, with no metal or other conductive materials exposed inside, except as specified in paragraph (d... the mine roof or other obstruction; (3) Except when persons are riding the belt to accompany...
[3D printing in neurosurgery: a specific model for patients with craniosynostosis].
Jiménez Ormabera, Borja; Díez Valle, Ricardo; Zaratiegui Fernández, Javier; Llorente Ortega, Marcos; Unamuno Iñurritegui, Xabier; Tejada Solís, Sonia
Craniosynostosis is a rare condition and requires a personalised surgical approach, which is why we consider the use of 3D printed models beneficial in the surgical planning of this procedure. Acrylonitrile butadiene styrene plastic skull models were designed and printed from CT images of patients between 3 and 6 months of age with craniosynostosis of different sutures. The models were used to simulate surgical procedures. Four models of four patients with craniosynostosis were produced: two with closure of the metopic suture and two with sagittal suture closure. The mean age of the patients was 5 months (3-6m) and the mean duration of the surgery was 286min (127-380min). The acrylonitrile butadiene styrene plastic models printed for the project proved to be optimal for the simulation of craniosynostosis surgeries, both anatomically and in terms of mechanical properties and reaction to surgical instruments. 3D printers have a wide range of medical applications and they offer an easy and affordable way to produce skull models. The acrylonitrile butadiene styrene material is suitable for the production of operable bone models as it faithfully reproduces the mechanical characteristics of bone tissue. Copyright © 2017 Sociedad Española de Neurocirugía. Publicado por Elsevier España, S.L.U. All rights reserved.
Naki, Mehmet Murat; Api, Oluş; Celik, Hasniye; Kars, Bülent; Yaşar, Esra; Unal, Orhan
2011-02-01
To compare Pfannenstiel-Kerr (PKM) and Misgav-Ladach (MLM) methods in terms of operation-related features and neonatal outcome in primary cesarean deliveries. A total of 180 pregnant women randomized into PKM (n = 90) or MLM (n = 90) groups were included in this study. Primary outcome measures were total operative and extraction times, Apgar score, blood loss, wound complications, and the suture use. Secondary outcome measures were wound seroma and infection incidence, time of bowel restitution, and the perceived pain. Total operation and extraction times were significantly shorter and less suture material was used in the MLM group than the PKM group (p < 0.001). Initially, higher scores obtained for 6 h-VAS in the MLM group (p < 0.05) were normalized after 24 h of the operation. PKM and MLM were similar in terms of preoperative and postoperative levels of hemoglobin and hematocrit, wound complication, bowel restitution, fever, seroma, infection, wound dehiscence and the need for transfusion, antibiotic, and analgesics. The operation-related morbidity of the MLM and PKM for primary C/S seem to be comparable; however, the MLM seems to be superior in terms of operation time and the amount of suture usage but inferior in pain scores in the early postoperative period.
Photocrosslinkable Gelatin/Tropoelastin Hydrogel Adhesives for Peripheral Nerve Repair.
Soucy, Jonathan R; Shirzaei Sani, Ehsan; Portillo Lara, Roberto; Diaz, David; Dias, Felipe; Weiss, Anthony S; Koppes, Abigail N; Koppes, Ryan A; Annabi, Nasim
2018-05-09
Suturing peripheral nerve transections is the predominant therapeutic strategy for nerve repair. However, the use of sutures leads to scar tissue formation, hinders nerve regeneration, and prevents functional recovery. Fibrin-based adhesives have been widely used for nerve reconstruction, but their limited adhesive and mechanical strength and inability to promote nerve regeneration hamper their utility as a stand-alone intervention. To overcome these challenges, we engineered composite hydrogels that are neurosupportive and possess strong tissue adhesion. These composites were synthesized by photocrosslinking two naturally derived polymers, gelatin-methacryloyl (GelMA) and methacryloyl-substituted tropoelastin (MeTro). The engineered materials exhibited tunable mechanical properties by varying the GelMA/MeTro ratio. In addition, GelMA/MeTro hydrogels exhibited 15-fold higher adhesive strength to nerve tissue ex vivo compared to fibrin control. Furthermore, the composites were shown to support Schwann cell (SC) viability and proliferation, as well as neurite extension and glial cell participation in vitro, which are essential cellular components for nerve regeneration. Finally, subcutaneously implanted GelMA/MeTro hydrogels exhibited slower degradation in vivo compared with pure GelMA, indicating its potential to support the growth of slowly regenerating nerves. Thus, GelMA/MeTro composites may be used as clinically relevant biomaterials to regenerate nerves and reduce the need for microsurgical suturing during nerve reconstruction.
Park, In-Seop; Kim, Sung-Jae
2006-08-01
We introduce a suture technique to repair a peripheral tear near the posterior tibial attachment of the posterior horn. A suture hook was inserted through the posteromedial portal, and the peripheral capsular rim was penetrated from superior to inferior by the sharp hook. Both relay limbs were brought out through the posteromedial portal. The outer limb of the superior peripheral capsular rim was identified with a hemostat. An 18-gauge spinal needle loaded with a No. 0 polydioxanone suture (PDS) was introduced into the joint from the anteromedial portal; it was passed through the joint space until it penetrated the inner torn meniscus. The PDS suture loaded within the needle was pushed into the joint and picked up through the posteromedial portal. The needle was pulled out of the torn meniscus and readvanced over it while the suture was kept loaded. The other limb of the suture from the tip of the spinal needle was retrieved through the posteromedial portal. The initial PDS suture limb was hooked to the shuttle-relay system; it then was passed through the inner torn meniscus and the peripheral capsular rim. The suture limb exiting from the peripheral capsular rim was used as a post and was joined to the other suture limb to form a sliding knot.
Loop ileostomy closure: comparison of cost effectiveness between suture and stapler.
Horisberger, Karoline; Beldi, Guido; Candinas, Daniel
2010-12-01
Closure of loop ileostomy can be safely performed using sutures or staplers. The aim of the present study was to compare the cost effectiveness of three different techniques. A total of 128 consecutive patients who underwent closure of loop ileostomy between January 2002 and December 2008 were analyzed retrospectively. The primary outcome parameter was operative cost. Closure of ileostomy was performed in 66 patients with hand-sewn anastomosis, in 25 patients with stapler only, and in 37 patients with a combination of stapler and suture. There were no differences in terms of early and late postoperative complications. Operative time was significantly longer for "suture only" (101.4 ± 26 min) than for "stapler/suture" (-4.9 min) and "stapler only" (-17.8 min); the difference between the three groups is significant (p = 0.05). Duration of hospital stay was not different among the three groups. Operative costs with "stapler/suture" (1,755.9 ± 355.6 EUR) were significantly higher than with "suture only" (-254 EUR; p = 0.001) and "stapler only" (-236 EUR; p = 0.005). Operative time using the stapler only is significantly shorter than with hand-sewn anastomosis or combinations of stapler and suture. Operative costs are significantly higher for a procedure that includes suture and stapler.
Securing stent during multi-stage laryngotracheoplasty--an evolved technique.
Siegel, Bianca; Bent, John P
2015-09-01
Multi-stage laryngotracheoplasty (LTP) typically requires a stent be secured to the airway for 2-6 weeks. Our technique has evolved over time to securing the stent to the strap muscles and tying a series of knots long enough to leave the suture tail protruding through the skin incision, which simplifies stent removal. Retrospective chart review. Twenty-four patients underwent multi-stage LTP at our institution from 2007 to 2013. Eight patients were excluded from the study because they either did not have a stent placed (n=4), or they had a t-tube placed which was not sutured in place (n=4). Of the remaining 16 patients, 62.5% (n=10) had their stent secured via sutures which were buried below the skin, and 37.5% (n=6) via a long suture tail which was left protruding through the end of the skin incision. An incision was required for stent removal 100% of buried sutures patients, and 33% of exposed suture patients (p=0.0009). Average operative time for stent removal was 60min in the buried sutures group, and 25min in the exposed sutures group (p=0.0075). Securing stents via an exposed suture technique decreases the need for making a skin incision during the second stage of the operation, and significantly decreases the operative time of the second stage. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
A comparison of lateral ankle ligament suture anchor strength.
Barber, F Alan; Herbert, Morley A; Crates, John M
2013-06-01
Lateral ankle ligament repairs increasingly use suture anchors instead of bone tunnels. Our purpose was to compare the biomechanical properties of a knotted and knotless suture anchor appropriate for a lateral ankle ligament reconstruction. In porcine distal fibulae, 10 samples of 2 different PEEK anchors were inserted. The attached sutures were cyclically loaded between 10N and 60N for 200 cycles. A destructive pull was performed and failure loads, cyclic displacement, stiffness, and failure mode recorded. PushLock 2.5 anchors failed before 200 cycles. PushLock 100 cycle displacement was less than Morphix 2.5 displacement (p<0.001). Ultimate failure load for anchors completing 200 cycles was 86.5N (PushLock) and 252.1N (Morphix) (p<0.05). The failure mode was suture breaking for all PushLocks while the Morphix failed equally by anchor breaking and suture breakage. The knotted Morphix demonstrated more displacement and greater failure strength than the knotless PushLock. The PushLock failed consistently with suture breaking. The Morphix anchor failed both by anchor breaking and by suture breaking. Copyright © 2012 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.
Wang, Wei-Wei; Dong, Bao-Cheng
2017-11-01
This systematic review applied meta-analytic procedures to evaluate the curative effect of trans-septal suturing versus nasal packing after septoplasty. Computerized search of the published literature in PubMed, EMBASE, CENTRAL, Cochrane Database of Systematic Reviews, WANFANG, CNKI databases. Randomized trials investigating trans-septal suturing versus nasal packing following septoplasty in patients with deviated nasal septum. Adhesion, septal hematoma, bleeding, septal perforation, infection, pain, headache, or residual septal deviation per randomized patients. 19 randomized controlled trials of 1845 subjects were included. Meta-analysis showed that postoperative pain, headache, and adhesion were significantly lower in trans-septal suturing group. Nasal packing and trans-septal suturing technique appear to be equivalent with regard to postoperative bleeding, hematoma, septal perforation, infection, and residual septal deviation. Trans-septal suturing technology is not only associated with less patient pain, headache, and lower occurrence rate of adhesion after septoplasty but it also relates to higher patient satisfaction and an improved quality of life. The suturing technology can be used as a substitute for traditional nasal packing of the first-line treatment. More well-designed studies are needed to confirm the effect of trans-septal suturing following septoplasty.
Arroyo-Hernández, M; Mellado-Romero, M A; Páramo-Díaz, P; Martín-López, C M; Cano-Egea, J M; Vilá Y Rico, J
2015-01-01
The purpose of this study is to analyze if there is any difference between the arthroscopic reparation of full-thickness supraspinatus tears with simple row technique versus suture bridge technique. We accomplished a retrospective study of 123 patients with full-thickness supraspinatus tears between January 2009 and January 2013 in our hospital. There were 60 simple row reparations, and 63 suture bridge ones. The mean age in the simple row group was 62.9, and in the suture bridge group was 63.3 years old. There were more women than men in both groups (67%). All patients were studied using the Constant test. The mean Constant test in the suture bridge group was 76.7, and in the simple row group was 72.4. We have also accomplished a statistical analysis of each Constant item. Strength was higher in the suture bridge group, with a significant statistical difference (p 0.04). The range of movement was also greater in the suture bridge group, but was not statistically significant. Suture bridge technique has better clinical results than single row reparations, but the difference is not statistically significant (p = 0.298).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Noda, Kazuo, E-mail: knoda@kuhp.kyoto-u.ac.jp; Nakamura, Tomoyuki; Komatsu, Yoshihiro
Craniofacial sutures govern the shape of the craniofacial skeleton during postnatal development. The differentiation of suture mesenchymal cells to osteoblasts is precisely regulated in part by signaling through cell surface receptors that interact with extracellular proteins. Here we report that fibulin-5, a key extracellular matrix protein, is important for craniofacial skeletal development in mice. Fibulin-5 is deposited as a fibrous matrix in cranial neural crest-derived mesenchymal tissues, including craniofacial sutures. Fibulin-5-null mice show decreased premaxillary bone outgrowth during postnatal stages. While premaxillo-maxillary suture mesenchymal cells in fibulin-5-null mice were capable of differentiating into osteoblasts, suture cells in mutant mice weremore » less proliferative. Our study provides the first evidence that fibulin-5 is indispensable for the regulation of facial suture mesenchymal cell proliferation required for craniofacial skeletal morphogenesis. - Highlights: • Fibulin-5 is deposited in cranial neural crest-derived mesenchymal tissues. • Fibulin-5-null mice show decreased premaxillary bone growth during postnatal stage. • Fibulin-5 is indispensable for facial suture mesenchymal cell proliferation.« less
[Mechanical suture in classic and laparoscopic general surgery].
Alecu, L; Pascu, A; Deacu, A; Corodeanu, G; Marin, A; Costan, I
2000-01-01
Of this working is the study of employment the mechanical suture in general surgery classic and laparoscopic. We analysed the possibility of accomplishment and postoperatory evolution of 104 mechanical sutures performed in 24 patients, with diverse surgery pathology, operated in Department of General Surgery, between January 1999 and January 2000. Mechanical sutures allowed us to minimize the duration of surgical interventions and to perform some difficult anastomotic assembles (sometimes including creation of organ substitute). We had only two postoperatory fistulas and two postoperatory haemorrhages from anastomotic area (both cases because of bad closing of clips, through tissue excess between anvil and cartridge of the stapler). There are certain advantages in using mechanical sutures (versus manual sutures) consisting in decreasing of time period, both in operation itself and in hospitalization, despite their high level cost.
Post Thyroidectomy Suture Granuloma: A Cytological Diagnosis
Javalgi, Anita P.; Arakeri, Surekha U.
2013-01-01
There are known post thyroidectomized complications, a suture granuloma being less frequent, with its late complication mimicking recurrent thyroid cancer. A suture granuloma is a benign, granulomatous inflammatory reaction that occurs due to the use of non absorbable suture. It constitutes one of the late complications which altogether make up less than 2% of its incidence. A suture granuloma is similar to a foreign body reaction and it usually develops slowly as a painless, palpable asymptomatic mass over the years. It mimics a cancer recurrence or a lymph node metastasis. Here, we are reporting a case of a post thyroidectomy suture granuloma in a 46 years old lady who presented with a painless swelling in the lateral neck, with a past history of thyroidectomy 5 years back. PMID:23730655
Neary, Kaitlin C; Mormino, Matthew A; Wang, Hongmei
2017-01-01
In stress-positive, unstable supination-external rotation type 4 (SER IV) ankle fractures, implant selection for syndesmotic fixation is a debated topic. Among the available syndesmotic fixation methods, the metallic screw and the suture button have been routinely compared in the literature. In addition to strength of fixation and ability to anatomically restore the syndesmosis, costs associated with implant use have recently been called into question. This study aimed to examine the cost-effectiveness of the suture button and determine whether suture button fixation is more cost-effective than two 3.5-mm syndesmotic screws not removed on a routine postoperative basis. Economic and decision analysis; Level of evidence, 2. Studies with the highest evidence levels in the available literature were used to estimate the hardware removal and failure rates for syndesmotic screws and suture button fixation. Costs were determined by examining the average costs for patients who underwent surgery for unstable SER IV ankle fractures at a single level-1 trauma institution. A decision analysis model that allowed comparison of the 2 fixation methods was developed. Using a 20% screw hardware removal rate and a 4% suture button hardware removal rate, the total cost for 2 syndesmotic screws was US$20,836 and the total effectiveness was 5.846. This yielded a total cost of $3564 per quality-adjusted life-year (QALY) over an 8-year time period. The total cost for suture button fixation was $19,354 and the total effectiveness was 5.904, resulting in a total cost of $3294 per QALY over the same time period. A sensitivity analysis was then conducted to assess suture button fixation costs as well as screw and suture button hardware removal rates. Other possible treatment scenarios were also examined, including 1 screw and 2 suture buttons for operative fixation of the syndesmosis. To become more cost-effective, the screw hardware removal rate would have to be reduced to less than 10%. Furthermore, fixation with a single suture button continued to be the dominant treatment strategy compared with 2 suture buttons, 1 screw, and 2 screws for syndesmotic fixation. This cost-effectiveness analysis suggests that for unstable SER IV ankle fractures, suture button fixation is more cost-effective than syndesmotic screws not removed on a routine basis. Suture button fixation was a dominant treatment strategy, because patients spent on average $1482 less and had a higher quality of life by 0.058 QALYs compared with patients who received fixation with 2 syndesmotic screws. Assuming that functional outcomes and failure rates were equivalent, screw fixation only became more cost-effective when the screw hardware removal rate was reduced to less than 10% or when the suture button cost exceeded $2000. In addition, fixation with a single suture button device proved more cost-effective than fixation with either 1 or 2 syndesmotic screws.
Gögler, E
1985-01-01
In different tables the most important faults with enteral sutures and anastomoses in general and at special operations are demonstrated: end-to-end anastomoses with congruent diameter, anastomoses with different diameters, B I, B II, low anterior resection, esophago-jejunostomy. Only if the surgeon has experience in standard technique, faults and risks with mechanical staplers and manual sutures, the advantage-progress of staplers will be effective avoiding special risks. Surgeons without experience may produce real catastrophes which may turn out hopeless without training in manual suture technique.
Ureteroscopic holmium laser cutting for inadvertently sutured drainage tube (report of five cases).
Gao, Xu; Lu, Xin; Ren, Shancheng; Xu, Chuanliang; Sun, Yinghao
2008-07-01
The aim of this paper is to report a simple solution for inadvertently sutured drainage tube after urological surgery and discuss the different managements according to different types of this embarrassing complication. From September 2001 to January 2007, five inadvertently sutured drainage tubes were treated with ureteroscopic holmium laser cutting for the suture. All drainage tubes were removed after the operation without other complications. Holmium laser cutting via ureteroscope is a simple solution for the embarrassing problem of inadvertently sutured drainage tube. It can save the patient from undergoing another open surgery.
Black, P
2000-01-01
Cerebrospinal fluid (CSF) leaks are relatively common following spinal or posterior fossa surgery. A midline dural tear in the spine is readily repaired by direct application of a suture. However, far-lateral or ventral dural tears are problematic. Fat is an ideal sealant because it is impermeable to water. In this paper the author reports his experience with using fat grafts for the prevention or repair of CSF leaks and proposes a technique in which a large sheet of fat, harvested from the patient's subcutaneous layer, is used to cover not only the dural tear(s) but all of the exposed dura and is tucked into the lateral recess. This procedure prevents CSF from seeping around the fat, which may be tacked to the dura with a few sutures. Fibrin glue is spread on the surface of the fat and is further covered with Surgicel or Gelfoam. For ventral dural tears (associated with procedures in which disc material is excised), fat is packed into the disc space to seal off the ventral dural leak. Leaks in the posterior fossa are managed similarly to those in the spine. Dural suture lines, following suboccipital or spinal intradural exploration, are prophylactically protected from CSF leakage in the same manner. With one exception, 27 dural tears noted during 1650 spinal procedures were successfully repaired using this technique. There was one case of postoperative CSF leakage in 150 cases in which intradural exploration for tumor or other lesions was undertaken. Both postoperative CSF leaks were controlled by applying additional skin sutures. The use of a fat graft is recommended as a rapid, effective means of prevention and repair of CSF leaks following posterior fossa and spinal surgery.
Amirkazem, Vejdan Seyyed; Malihe, Khosravi
2017-02-01
Spleen is the most common organ damaged in cases of blunt abdominal trauma and splenectomy and splenorrhaphy are the main surgical procedures that are used in surgical treatment of such cases. In routine open splenectomy cases, after laparotomy, application of sutures in splenic vasculature is the most widely used procedure to cease the bleeding. This clinical trial evaluates the role and benefits of the Ligasure™ system in traumatic splenectomy without using any suture materials and compares the result with conventional method of splenectomy. After making decision for splenectomy secondary to a blunt abdominal trauma, patients in control group (39) underwent splenectomy using conventional method with silk suture ligation of splenic vasculature. In the interventional group (41) a Ligasure™ vascular sealing system was used for ligating of the splenic vein and artery. The results of operation time, volume of intra-operation bleeding and post-operative complications were compared in both groups. The mean operation times in control and interventional group were 21 and 12 min respectively (p < 0.05). The average volume of bleeding in control group during open splenectomy was 280 cc, but in the interventional group decreased significantly to 80 ml (p < 0.05) using the Ligasure system. Post-operative complications such as bleeding were non-existent in both groups. The application of Ligasure™ in blunt abdominal trauma for splenectomy not only can decrease the operation time but also can decrease the volume of bleeding during operation without any additional increase in post-operative complications. This method is recommendable in traumatic splenic injuries that require splenectomy in order to control the bleeding as opposed to use of traditional silk sutures. Copyright © 2016 IJS Publishing Group Ltd. Published by Elsevier Ltd. All rights reserved.
Goel, Ruchi; Kishore, Divya; Nagpal, Smriti; Kumar, Sushil; Rathie, Neha
2017-01-01
Context: Conjunctivodacryocystorhinostomy (CDCR) is the procedure of choice for proximal canalicular blocks. However, the complications of tube migration and extrusion limit its widespread practice. Aim: The aim of this study is to evaluate the efficacy and complications of the new “mirror tuck technique” for fixation of lacrimal bypass glass tube without holes in proximal canalicular blocks in laser CDCR. Materials and Methods: A prospective interventional study was conducted in forty consecutive eyes of adult patients, undergoing 980 nm diode laser CDCR for proximal canalicular blocks. After creating the tract under endoscopic guidance, the collar of the glass tube was fixed to the conjunctiva with 6-0 prolene suture by “mirror tuck technique.” Success was defined as the absence of extrusion of tube with patent tract and relief in epiphora at 1 year of follow-up. Results: Both anatomical and functional success was achieved in 39 (97.5%) cases. Tube displacement occurred in one patient suffering from allergic conjunctivitis in which the tube had to be removed. A temporary heaviness was reported by 5 (12.5%) patients till about 2 weeks. Conjunctival overgrowth over the tube occurred in 1 (2.5%) eye at 5 months which was excised and treated with application of 0.02% mitomycin C with no subsequent recurrence. There were no cases of suture abscess or suture intolerance warranting tube removal. Conclusion: “Mirror tuck technique” is an effective method for tube fixation (for tube without holes) in CDCR. However, it is important to position the conjunctival opening so as to leave sufficient space for passage of sutures for anchorage medially. PMID:28513491
Long-term follow-up results of umbilical hernia repair
Venclauskas, Linas; Zilinskas, Justas; Zviniene, Kristina; Kiudelis, Mindaugas
2017-01-01
Introduction Multiple suture techniques and various mesh repairs are used in open or laparoscopic umbilical hernia (UH) surgery. Aim To compare long-term follow-up results of UH repair in different hernia surgery groups and to identify risk factors for UH recurrence. Material and methods A retrospective analysis of 216 patients who underwent elective surgery for UH during a 10-year period was performed. The patients were divided into three groups according to surgery technique (suture, mesh and laparoscopic repair). Early and long-term follow-up results including hospital stay, postoperative general and wound complications, recurrence rate and postoperative patient complaints were reviewed. Risk factors for recurrence were also analyzed. Results One hundred and forty-six patients were operated on using suture repair, 52 using open mesh and 18 using laparoscopic repair technique. 77.8% of patients underwent long-term follow-up. The postoperative wound complication rate and long-term postoperative complaints were significantly higher in the open mesh repair group. The overall hernia recurrence rate was 13.1%. Only 2 (1.7%) patients with small hernias (< 2 cm) had a recurrence in the suture repair group. Logistic regression analysis showed that body mass index (BMI) > 30 kg/m2, diabetes and wound infection were independent risk factors for umbilical hernia recurrence. Conclusions The overall umbilical hernia recurrence rate was 13.1%. Body mass index > 30 kg/m2, diabetes and wound infection were independent risk factors for UH recurrence. According to our study results, laparoscopic medium and large umbilical hernia repair has slight advantages over open mesh repair concerning early postoperative complications, long-term postoperative pain and recurrence. PMID:29362649
Modified Endonasal Tongue-in-Groove Technique.
Kadakia, Sameep; Ovchinsky, Alexander
2016-10-01
Achieving stable and desirable changes in tip rotation (TR) and tip projection (TP) is among the primary goals of modern day rhinoplasty. The tongue-in-groove (TIG) technique is one technique in rhinoplasty used to improve TR and/or TP. Performing TIG endonasally using a permanent suture can be quite cumbersome as the suture needs to be buried under the skin. We describe a variation of TIG technique for endonasal rhinoplasty using a permanent suture buried in small columellar skin incisions. The technique details are described and the postoperative changes in TR and TP are analyzed for the degree of change and longevity. A retrospective review of the preoperative and postoperative photographs of 12 patients treated with the endonasal TIG technique were analyzed for changes in TR and TP. Out of 12 patients, there were seven females (58.3%) and five males (41.7%), with age ranging from 17 to 49 years. The follow-up ranged from 6 months to 53 months, with mean follow-up of 12.1 months. All patients were treated by the senior author in a major New York City hospital. Postoperative changes in TR and TP were compared by measuring the nasolabial angle as well as the Goode ratio using a photo editing software. Using a t-test and a p-value criteria of 0.05, the difference between the preoperative and postoperative TR (p = 0.0069) and TP (p = 0.026) was found to be statistically significant. None of the study patients developed any complications related to the use of a permanent suture material during the follow-up period. Our modified TIG technique is a quick, reliable, and safe option in the surgical armamentarium to achieve desired changes in TR and/or TP. 4. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Roth, Beat; Birkhäuser, Frédéric D; Thalmann, George N; Zehnder, Pascal
2013-11-01
WHAT'S KNOWN ON THE SUBJECT? AND WHAT DOES THE STUDY ADD?: The EndoSew(®) prototype was first tested in a porcine model several years ago. The investigators found it both simple to master and reliable, its greatest advantage being a 2.4-fold time saving compared with straight laparoscopic suturing. In addition to that publication, there is a single case report describing the performance of an open EndoSew(®) suture to close parts (16 cm) of an ileal neobladder. The time for suturing the 16 cm ileum was 25 min, which is in line with our experience. The knowledge on this subject is limited to these two publications. We report on the first consecutive series of ileal conduits performed in humans using the novel prototype sewing device EndoSew(®). The study shows that the beginning and the end of the suture process represent the critical procedural steps. It also shows that, overall, the prototype sewing machine has the potential to facilitate the intracorporeal suturing required in reconstructive urology for construction of urinary diversions. To evaluate the feasibility and safety of the novel prototype sewing device EndoSew(®) in placing an extracorporeal resorbable running suture for ileal conduits. We conducted a prospective single-centre pilot study of 10 consecutive patients undergoing ileal conduit, in whom the proximal end of the ileal conduit was closed extracorporeally using an EndoSew(®) running suture. The primary endpoint was the safety of the device and the feasibility of the sewing procedure which was defined as a complete watertight running suture line accomplished by EndoSew(®) only. Watertightness was assessed using methylene blue intraoperatively and by loopography on postoperative days 7 and 14. Secondary endpoints were the time requirements and complications ≤30 days after surgery. A complete EndoSew(®) running suture was feasible in nine patients; the suture had to be abandoned in one patient because of mechanical failure. In three patients, two additional single freehand stitches were needed to anchor the thread and to seal tiny leaks. Consequently, all suture lines in 6/10 patients were watertight with EndoSew(®) suturing alone and in 10/10 patients after additional freehand stitches. The median (range) sewing time was 5.5 (3-10) min and the median (range) suture length was 4.5 (2-5.5) cm. There were no suture-related complications. The EndoSew(®) procedure is both feasible and safe. After additional freehand stitches in four patients all sutures were watertight. With further technical refinements, EndoSew(®) has the potential to facilitate the intracorporeal construction of urinary diversions. © 2013 BJU International.
Lorbach, Olaf; Bachelier, Felix; Vees, Jochen; Kohn, Dieter; Pape, Dietrich
2008-08-01
Double-row repair is suggested to have superior biomechanical properties in rotator cuff reconstruction compared with single-row repair. However, double-row rotator cuff repair is frequently compared with simple suture repair and not with modified suture configurations. Single-row rotator cuff repairs with modified suture configurations have similar failure loads and gap formations as double-row reconstructions. Controlled laboratory study. We created 1 x 2-cm defects in 48 porcine infraspinatus tendons. Reconstructions were then performed with 4 single-row repairs and 2 double-row repairs. The single-row repairs included transosseous simple sutures; double-loaded corkscrew anchors in either a double mattress or modified Mason-Allen suture repair; and the Magnum Knotless Fixation Implant with an inclined mattress. Double-row repairs were either with Bio-Corkscrew FT using modified Mason-Allen stitches or a combination of Bio-Corkscrew FT and PushLock anchors using the SutureBridge Technique. During cyclic load (10 N to 60-200 N), gap formation was measured, and finally, ultimate load to failure and type of failure were recorded. Double-row double-corkscrew anchor fixation had the highest ultimate tensile strength (398 +/- 98 N) compared to simple sutures (105 +/- 21 N; P < .0001), single-row corkscrews using a modified Mason-Allen stitch (256 +/- 73 N; P = .003) or double mattress repair (290 +/- 56 N; P = .043), the Magnum Implant (163 +/- 13 N; P < .0001), and double-row repair with PushLock and Bio-Corkscrew FT anchors (163 +/- 59 N; P < .0001). Single-row double mattress repair was superior to transosseous sutures (P < .0001), the Magnum Implant (P = .009), and double-row repair with PushLock and Bio-Corkscrew FT anchors (P = .009). Lowest gap formation was found for double-row double-corkscrew repair (3.1 +/- 0.1 mm) compared to simple sutures (8.7 +/- 0.2 mm; P < .0001), the Magnum Implant (6.2 +/- 2.2 mm; P = .002), double-row repair with PushLock and Bio-Corkscrew FT anchors (5.9 +/- 0.9 mm; P = .008), and corkscrews with modified Mason-Allen sutures (6.4 +/- 1.3 mm; P = .001). Double-row double-corkscrew anchor rotator cuff repair offered the highest failure load and smallest gap formation and provided the most secure fixation of all tested configurations. Double-loaded suture anchors using modified suture configurations achieved superior results in failure load and gap formation compared to simple suture repair and showed similar loads and gap formation with double-row repair using PushLock and Bio-Corkscrew FT anchors. Single-row repair with modified suture configurations may lead to results comparable to several double-row fixations. If double-row repair is used, modified stitches might further minimize gap formation and increase failure load.
Barber, F Alan; Herbert, Morley A; Schroeder, F Alexander; Aziz-Jacobo, Jorge; Mays, Matthew M; Rapley, Jay H
2010-03-01
To evaluate the strength and suture-tendon interface security of various suture anchors triply and doubly loaded with ultrahigh-molecular weight polyethylene-containing sutures and to evaluate the relative effectiveness of placing these anchors in a single-row or double-row arrangement by cyclic loading and then destructive testing. The infraspinatus muscle was reattached to the original humeral footprint by use of 1 of 5 different repair patterns in 40 bovine shoulders. Two single-row repairs and three double-row repairs were tested. High-strength sutures were used for all repairs. Five groups were studied: group 1, 2 triple-loaded screw suture anchors in a single row with simple stitches; group 2, 2 triple-loaded screw anchors in a single row with simple stitches over a fourth suture passed perpendicularly ("rip-stop" stitch); group 3, 2 medial and 2 lateral screw anchors with a single vertical mattress stitch passed from the medial anchors and 2 simple stitches passed from the lateral anchors; group 4, 2 medial double-loaded screw anchors tied in 2 mattress stitches and 2 push-in lateral anchors capturing the medial sutures in a "crisscross" spanning stitch; and group 5, 2 medial double-loaded screw anchors tied in 2 mattress stitches and 2 push-in lateral anchors creating a "suture-bridge" stitch. The specimens were cycled between 10 and 180 N at 1.0 Hz for 3,500 cycles or until failure. Endpoints were cyclic loading displacement (5 and 10 mm), total displacement, and ultimate failure load. A single row of triply loaded anchors was more resistant to stretching to a 5- and 10-mm gap than the double-row repairs with or without the addition of a rip-stop suture (P < .05). The addition of a rip-stop stitch made the repair more resistant to gap formation than a double row repair (P < .05). The crisscross double row created by 2 medial double-loaded suture anchors and 2 lateral push-in anchors stretched more than any other group (P < .05). Double-row repairs with either crossing sutures or 4 separate anchor points were more likely to fail (5- or 10-mm gap) than a single-row repair loaded with 3 simple sutures. The triple-loaded anchors with ultrahigh-molecular weight polyethylene-containing sutures placed in a single row were more resistant to stretching than the double-row groups. Copyright 2010 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Cox, Joseph T; Shorten, Peter L; Gould, Gregory C; Markert, Ronald J; Barnett, Michael D; Laughlin, Richard T
2014-11-01
Surgical treatment of insertional Achilles tendinopathy often involves detachment and debridement of the Achilles tendon insertion. A recent study has shown that knotted suture bridge fixation of the Achilles to the calcaneus is biomechanically superior to single-row fixation, but there is an absence of literature on the use of different suture bridge constructs to repair the Achilles tendon. There will be no significant difference in the load to failure, mode of failure, tendon strain, tendon stiffness, repair site gapping, or footprint size when comparing knotted suture bridge repair to knotless suture bridge repair of the Achilles tendon after detachment for insertional Achilles tendinopathy. Controlled laboratory study. A single specimen from each pair of 10 cadaveric Achilles tendons was randomized to 1 of 2 Achilles insertion repair groups: knotted (n = 10) or knotless (n = 10) suture bridge repair. Repaired footprint size was measured, and then cyclic testing from 10 to 100 N for 2000 cycles was performed. This was followed by measurement of tendon strain, repair site displacement, load to failure, and tendon stiffness. The knotted suture bridge repair had a significantly higher load to failure compared with the knotless suture bridge (mean ± SD, 317.8 ± 93.6 N vs 196.1 ± 12.1 N, respectively; P = .001). All constructs failed at the tendon-suture interface. Tendon strain after cyclic testing was significantly greater in the knotless (1.20 ± 1.05) compared with the knotted (0.39 ± 0.4) suture repair groups (P = .011). There was no significant difference in footprint size between the knotted (230.3 ± 63.3 mm(2)) and knotless (248.5 ± 48.8 mm(2)) groups (P = .40). There was also no significant difference in stiffness (knotted = 76.4 ± 8.0 N/mm; knotless = 69.6 ± 10.9 N/mm; P = .17) and repair site displacement after cyclic testing (knotted = 2.8 ± 1.2 mm; knotless = 3.6 ± 1.1 mm; P = .17). During suture bridge repair of the Achilles tendon after detachment, knots at the proximal suture anchors significantly improve the biomechanical strength of the repair. This study demonstrated that the knotless suture bridge repair had a significantly lower load to failure than the knotted suture bridge. Surgeons should be aware of these biomechanical differences, as they influence the postoperative rehabilitation protocol and may lead to higher surgical complication rates. © 2014 The Author(s).
Cerminara, Anthony J; LaPrade, Christopher M; Smith, Sean D; Ellman, Michael B; Wijdicks, Coen A; LaPrade, Robert F
2014-12-01
A common treatment for posterior meniscal root tears is transtibial pull-out repair, which has been biomechanically reported to restore tibiofemoral contact mechanics to those of the intact knee. Biomechanical data suggest that there is significant displacement of the repaired meniscal root with cyclic loading, which may be responsible for the poor healing and meniscal extrusion demonstrated in some clinical studies. The purpose of this study was to quantify the time-zero displacement of the posterior meniscal root in response to cyclic loading after transtibial pull-out repair and to quantify the individual contributions to displacement of the following: (1) suture elongation, (2) button-bone interface, and (3) meniscus-suture interface. The meniscus-suture interface was hypothesized to result in significantly more displacement than the button-bone interface or suture elongation. Descriptive laboratory study. Transtibial pull-out repair of the posterior medial meniscal root was performed in 6 porcine knees, and cyclic displacement was measured using a loading protocol representative of postoperative rehabilitation. Displacement from (1) suture elongation, (2) the button-bone interface, and (3) the meniscus-suture interface was determined by cyclically loading 6 specimens for each construct using the same loading protocol to determine the contribution of each component to the overall displacement of the repair construct. After 1000 cycles, the repair construct displaced by a mean of 3.28 mm (95% CI, 2.07-4.49). The meniscus-suture component (mean, 2.52 mm; 95% CI, 2.21-2.83) displaced significantly more than the button-bone component (mean, 0.90 mm; 95% CI, 0.64-1.15; P = .006) and suture elongation component (mean, 0.71 mm; 95% CI, 0.36-1.06; P = .006) after 1000 cycles. Displacement of the button-bone and suture elongation components was not significantly different after 1000 cycles (P = .720). There was substantial displacement of the posterior medial meniscal root repaired with the transtibial pull-out technique under a cyclic loading protocol simulating postoperative rehabilitation. The meniscus-suture interface contributed to significantly more displacement than the button-bone interface and suture elongation in the transtibial pull-out repair construct. The results provide a framework for optimizing the transtibial pull-out repair technique. Future studies should focus on improving suture fixation strength within the meniscus-suture interface. © 2014 The Author(s).
Automation of a suturing device for minimally invasive surgery.
Göpel, Tobias; Härtl, Felix; Schneider, Armin; Buss, Martin; Feussner, Hubertus
2011-07-01
In minimally invasive surgery, hand suturing is categorized as a challenge in technique as well as in its duration. This calls for an easily manageable tool, permitting an all-purpose, cost-efficient, and secure viscerosynthesis. Such a tool for this field already exists: the Autosuture EndoStitch(®). In a series of studies the potential for the EndoStitch to accelerate suturing has been proven. However, its ergonomics still limits its applicability. The goal of this study was twofold: propose an optimized and partially automated EndoStitch and compare the conventional EndoStitch to the optimized and partially automated EndoStitch with respect to the speed and precision of suturing. Based on the EndoStitch, a partially automated suturing tool has been developed. With the aid of a DC motor, triggered by a button, one can suture by one-fingered handling. Using the partially automated suturing manipulator, 20 surgeons with different levels of laparoscopic experience successfully completed a continuous suture with 10 stitches using the conventional and the partially automated suture manipulator. Before that, each participant was given 1 min of instruction and 1 min for training. Absolute suturing time and stitch accuracy were measured. The quality of the automated EndoStitch with respect to manipulation was tested with the aid of a standardized questionnaire. To compare the two instruments, t tests were used for suturing accuracy and time. Of the 20 surgeons with laparoscopic experience (fewer than 5 laparoscopic interventions, n=9; fewer than 20 laparoscopic interventions, n=7; more than 20 laparoscopic interventions, n=4), there was no significant difference between the two tested systems with respect to stitching accuracy. However, the suturing time was significantly shorter with the Autostitch (P=0.01). The difference in accuracy and speed was not statistically significant considering the laparoscopic experience of the surgeons. The weight and size of the Autostitch have been criticized as well as its cable. However, the comfortable handhold, automatic needle change, and ergonomic manipulation have been rated positive. Partially automated suturing in minimally invasive surgery offers advantages with respect to the speed of operation and ergonomics. Ongoing work in this field has to concentrate on minimization, implementation in robotic systems, and development of new operation methods (NOTES).
Leine, Marit; Wahl, Astrid Klopstad; Borge, Christine Råheim; Hustavenes, Magne; Bondevik, Hilde
2017-09-01
To explore chronic obstructive pulmonary disease patients' experiences with a partnership-based nursing practice programme in the home setting. Patients with chronic obstructive pulmonary disease suffer from psychological and physiological problems, especially when they return home after hospitalisation from exacerbation. Many express a need for information and knowledge about chronic obstructive pulmonary disease. Partnership as practice is a patient-centred framework providing an individualised practice for each patient. This study intends to achieve a nuanced and improved understanding of chronic obstructive pulmonary disease patients' experiences with a partnership-based nursing practice programme comprising home visits from a respiratory nurse after hospital discharge, alongside interdisciplinary collaboration. This study has a qualitative design with interviews. Six individual semi-structured interviews collected in 2012-2013 constitute the material. Interviews were recorded, transcribed to written text and analysed using systematic text condensation. Three key themes were identified: to be seen, talked with and understood; healthcare support at home-continuity, practical support and facilitation; and exchange of knowledge. However, there were two generic themes that permeated the material: feeling safe and comforted, and motivation to achieve better health. Patients with chronic obstructive pulmonary disease can experience feeling safe and comforted, and be motivated to make changes in order to achieve better health after participating in a partnership-based nursing practice programme that includes home visits from a respiratory nurse and interdisciplinary cooperation after hospital discharge. To feel safe is of great importance, and how this relates to the patient's ability to cope with illness should be explored in further research. The results suggest that the partnership-based nursing practice programme that includes home visits and interdisciplinary collaboration can be a good approach to meeting the complexity of the chronic obstructive pulmonary disease patient's health needs. © 2017 John Wiley & Sons Ltd.
Custis, Trenton; Armstrong, April W; King, Thomas H; Sharon, Victoria R; Eisen, Daniel B
2015-08-01
Although applying adhesive strips to a wound closure has been shown to have outcomes equivalent to those with cuticular suturing, it is unknown whether adhesive strips provide additional benefit compared with dermal suturing alone. To determine whether the addition of adhesive strips to a wound closed with buried interrupted subcuticular sutures improves outcomes following wound closure. A prospective, randomized split-wound intervention was conducted between November 14, 2013, and May 16, 2014, in patients who underwent cutaneous surgical procedures at the University of California, Davis, outpatient dermatology clinic. Fifty-seven patients 18 years or older with postoperative defects of at least 3 cm, resulting from either Mohs micrographic surgical procedures or surgical excision, were screened for participation. Nine patients were excluded and 48 were enrolled. Half of each wound was randomized to receive buried interrupted subcuticular sutures and overlying adhesive strips and the other half received buried interrupted subcuticular sutures only. At 3 months' follow-up, each patient and 2 blinded observers evaluated the wound using the Patient Observer Scar Assessment Scale. The total mean (SD) Patient Observer Scar Assessment Scale score for observers for the side that received a combination of adhesive strips and buried interrupted subcuticular suturing (12.3 [4.8]) and the side that received sutures only (12.9 [6.3]) did not differ significantly at 3 months (P = .32). There was no significant difference in the total patient assessment scale score between the combination closure (14.0 [7.6]) and sutures only (14.7 [7.6]) sides at 3 months (P = .39). There was also no significant difference between the 2 closure methods in terms of mean (SD) scar width (both methods: 1.1 [0.8] mm, P = .89) at follow-up. Combination closure with adhesive strips and buried interrupted subcuticular suturing was not significantly associated with improved overall scar assessment compared with buried interrupted subcuticular suturing alone when evaluated by blinded observers or the patients themselves. Our results do not support the use of adhesive strips as a means to improve cosmetic outcomes or reduce scar width. clinicaltrials.gov Identifier: NCT01979497.
Assessment of the Resistance of Several Suture Techniques in Human Cadaver Achilles Tendons.
Manent, Andrea; Lopez, Laia; Vilanova, Joan; Mota, Tiago; Alvarez, Jordi; Santamaría, Alejandro; Oliva, Xavier Martí
Many treatments are available for acute Achilles tendon ruptures, conservative and surgical, with none superior to another. For surgical treatment, one can use various techniques. Recent studies have shown that double stitches are superior to simple sutures. Therefore, in the present study, we sought to determine the suture technique that is the most resistant to rupture. We performed an experimental anatomic study with 27 fresh-frozen human cadaveric Achilles tendons obtained through the body donation program of the University of Barcelona, testing the maximum strength. We simulated a rupture by performing resection in the middle portion of the tendon, 4 cm proximal to the calcaneus insertion. We then evaluated the double Kessler, double Bunnell, Krackow, and percutaneous Ma and Griffith technique. We used absorbable suture (polydioxanone no. 1) with all the techniques. Traction was performed using a machine that pulls the tendon at 10 to 100 N in 1000 repetitive cycles. Statistical analysis was performed using the χ 2 test and analysis of variance, with the 95% confidence intervals (p < .05). All repairs failed at the site of the suture knots, with none pulling out through the substance of the tendon. We found no significant differences among the different open suture techniques (p > .05). The Krackow suture presented with superior resistance, with a rupture rate 16.70% but with a mean elongation of 7.11 mm. The double Bunnell suture had the same rupture rate as the Krakow suture (16.70%) but with an inferior mean elongation of 4.53 mm. The Krackow and Bunnell suture were superior in endurance, strength of failure, and primary stability compared with the other suture types. However, the former presented with greater tendon elongation, although the difference was not statistically significant. Therefore, according to our findings and the published data, we recommend double Bunnell sutures for the surgical treatment of acute Achilles tendon rupture. Copyright © 2017 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brown, Richard S.; Deters, Katherine A.; Cook, Katrina V.
Reductions in the size of acoustic transmitters implanted in migrating juvenile salmonids have resulted in the ability to make shorter incisions that may warrant using only a single suture for closure. However, it is not known if one suture will sufficiently hold the incision closed, particularly when outward pressure is placed on the surgical site such as when migrating fish experience pressure changes associated with passage at hydroelectric dams. The objective of this research was to evaluate the effectiveness of single-suture incision closures on juvenile Chinook salmon (Oncorhynchus tshawytscha). Juvenile Chinook salmon were surgically implanted with a 2012 Juvenile Salmonmore » Acoustic Telemetry System (JSATS) transmitter (0.30 g) and a passive integrated transponder tag (0.10 g) and incisions were closed with either one suture or two sutures. Mortality and tag retention were monitored and fish were examined after 7 and 14 days to evaluate tissue responses. In a separate experiment, surgically implanted fish were exposed to simulated turbine passage and then examined for expulsion of transmitters, expulsion of viscera through the incision, and mortal injury. With incisions closed using a single suture, there was no mortality or tag loss and similar or reduced tissue reaction compared to incisions closed with two sutures. Further, surgery time was significantly reduced when one suture was used, which leads to less handling and reduced stress. No tags were expelled during pressure scenarios and expulsion of viscera only occurred in two non-mortally injured fish (5%) with single sutures that were also exposed to very high pressure changes. No viscera expulsion was present in fish exposed to pressure scenarios likely representative of hydroturbine passage at many Columbia River dams (e.g. <2.7 ratio of pressure change; an acclimation pressure of 146.2 absolute kpa and a lowest exposure pressure of ~ 53.3 absolute kpa). Based on these results, we recommend the use of a single suture for surgical implantation of transmitters with incisions that are approximately 5 1/2 mm long after tag insertion.« less
Standardization of Code on Dental Procedures
1992-02-13
oral hard and soft tissues using a periodontal probe, mirror, and explorer, and bitewing, panoramic, or other radiographs as...of living tissue or inert material into periodontal osseous defects to regenerate new periodontal attachment (bone, periodontal ligament, and cementum...Simple (up to 5 cm). Repair and/or suturing of simple to moderately complicated wounds of facial and/or oral soft tissues . 7211 1.8 Repair
Van Eijk, F; Saris, D B F; Riesle, J; Willems, W J; Van Blitterswijk, C A; Verbout, A J; Dhert, W J A
2004-01-01
Anterior cruciate ligament (ACL) reconstruction surgery still has important problems to overcome, such as "donor site morbidity" and the limited choice of grafts in revision surgery. Tissue engineering of ligaments may provide a solution for these problems. Little is known about the optimal cell source for tissue engineering of ligaments. The aim of this study is to determine the optimal cell source for tissue engineering of the anterior cruciate ligament. Bone marrow stromal cells (BMSCs), ACL, and skin fibroblasts were seeded onto a resorbable suture material [poly(L-lactide/glycolide) multifilaments] at five different seeding densities, and cultured for up to 12 days. All cell types tested attached to the suture material, proliferated, and synthesized extracellular matrix rich in collagen type I. On day 12 the scaffolds seeded with BMSCs showed the highest DNA content (p < 0.01) and the highest collagen production (p < 0.05 for the two highest seeding densities). Scaffolds seeded with ACL fibroblasts showed the lowest DNA content and collagen production. Accordingly, BMSCs appear to be the most suitable cells for further study and development of tissue-engineered ligament.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Deters, Katherine A.; Brown, Richard S.; Boyd, James W.
2012-01-02
The size reduction of acoustic transmitters has led to a reduction in the length of incision needed to implant a transmitter. Smaller suture knot profiles and fewer sutures may be adequate for closing an incision used to surgically implant an acoustic microtransmitter. As a result, faster surgery times and reduced tissue trauma could lead to increased survival and decreased infection for implanted fish. The objective of this study was to assess the effects of five suturing techniques on mortality, tag and suture retention, incision openness, ulceration, and redness in juvenile Chinook salmon Oncorhynchus tshawytscha implanted with acoustic microtransmitters. Suturing wasmore » performed by three surgeons, and study fish were held at two water temperatures (12°C and 17°C). Mortality was low and tag retention was high for all treatments on all examination days (7, 14, 21, and 28 days post-surgery). Because there was surgeon variation in suture retention among treatments, further analyses included only the one surgeon who received feedback training in all suturing techniques. Incision openness and tissue redness did not differ among treatments. The only difference observed among treatments was in tissue ulceration. Incisions closed with a horizontal mattress pattern had more ulceration than other treatments among fish held for 28 days at 17°C. Results from this study suggest that one simple interrupted 1 × 1 × 1 × 1 suture is adequate for closing incisions on fish under most circumstances. However, in dynamic environments, two simple interrupted 1 × 1 × 1 × 1 sutures should provide adequate incision closure. Reducing bias in survival and behavior tagging studies is important when making comparisons to the migrating salmon population. Therefore, by minimizing the effects of tagging on juvenile salmon (reduced tissue trauma and reduced surgery time), researchers can more accurately estimate survival and behavior.« less
Diagnostic performance of skeletal maturity for the assessment of midpalatal suture maturation.
Angelieri, Fernanda; Franchi, Lorenzo; Cevidanes, Lucia H S; McNamara, James A
2015-12-01
The aim of this study was to analyze the diagnostic performance of the cervical vertebral maturation (CVM) method in estimating accurately the stages of maturation of the midpalatal suture. Cone-beam computed tomography (CBCT) images from 142 subjects (84 female, 58 male; mean age, 14.8 ± 9.7 years) were analyzed by 2 calibrated examiners to define, by visual analysis, the maturational stages of the cervical vertebrae and the midpalatal suture. These CBCT images were required by orthodontists and surgeons for diagnosis and treatment purposes. Positive likelihood ratios (LHRs) were calculated to evaluate the diagnostic performance of the CVM stages in identifying the maturational stages of the midpalatal suture. Positive LHRs greater than 10 were found for several cervical vertebral stages (CSs), including CS1 and CS2 for the identification of midpalatal suture stages A and B, CS3 for the diagnosis of midpalatal suture stage C, and CS5 for the assessment of midpalatal suture stages D and E. These positive LHRs indicated large and often conclusive increases in the likelihood that the CVM stages were associated with specific stages of midpalatal suture maturation. At CS4, there were a moderate positive LHR for stage C and low positive LHRs for stages D and E. Most CVM stages can be used for the diagnosis of the stages of maturation of the midpalatal suture, so that CBCT imaging may not be necessary in these patients. In the postpubertal period, however, an assessment of the midpalatal suture maturation using CBCT images may be indicated in deciding between conventional rapid maxillary expansion and surgically assisted rapid maxillary expansion. On the other hand, if the CVM stage cannot be assessed, chronologic age may be a viable alternative to predict some midpalatal suture stages (particularly the early stages). Copyright © 2015 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.
Comparison of Suture-Based Anchors and Traditional Bioabsorbable Anchors in Foot and Ankle Surgery.
Hembree, W Chad; Tsai, Michael A; Parks, Brent G; Miller, Stuart D
We compared the pullout strength of a suture-based anchor versus a bioabsorbable anchor in the distal fibula and calcaneus and evaluated the relationship between bone mineral density and peak load to failure. Eight paired cadaveric specimens underwent a modified Broström procedure and Achilles tendon reattachment. The fibula and calcaneus in the paired specimens received either a suture-based anchor or a bioabsorbable suture anchor. The fibular and calcaneal specimens were loaded to failure, defined as a substantial decrease in the applied load or pullout from the bone. In the fibula, the peak load to failure was significantly greater with the suture-based versus the bioabsorbable anchors (133.3 ± 41.8 N versus 76.8 ± 35.3 N; p = .002). No significant difference in load with 5 mm of displacement was found between the 2 groups. In the calcaneus, no difference in the peak load to failure was found between the 2 groups, and the peak load to failure with 5 mm of displacement was significantly lower with the suture-based than with the bioabsorbable anchors (52.2 ± 9.8 N versus 75.9 ± 12.4 N; p = .003). Bone mineral density and peak load to failure were significantly correlated in the fibula with the suture-based anchor. An innovative suture-based anchor had a greater peak load to failure compared with a bioabsorbable anchor in the fibula. In the calcaneus, the load at 5 mm of displacement was significantly lower in the suture-based than in the bioabsorbable group. The correlation findings might indicate the need for a cortical bone shelf with the suture-based anchor. Suture-based anchors could be a viable alternative to bioabsorbable anchors for certain foot and ankle procedures. Copyright © 2016 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.
Chu, Haikun; Xu, Yanbin; Chu, Haipeng; Xu, Yajun; Zhou, Fengji; Yu, Xin; Li, Hui; Ji, Xiaofeng
2012-06-01
To investigate the effectiveness of modified percutaneous suture in repairing acute closed Achilles tendon rupture by comparing with conventional open suture. Between January 2006 and October 2009, 50 patients with acute closed Achilles tendon rupture were treated with modified percutaneous suture by making 5 small incisions at both sides of Achilles tendon and zigzag suture (improved group, n=22) and with Kessler suture (conventional group, n=28), respectively. No significant difference was found in gender, age, time from injury to operation between 2 groups (P > 0.05). In improved group, the patients achieved healing of incisions by first intention after operation and no complication occurred; however, incision infection occurred in 1 case, Achilles tendon re-rupture in 1 case, and incision scar contracture in 2 cases in conventional group. The operation time of improved group [(38.7 +/- 6.6) minutes] was significantly shorter (t=-12.29, P=0.00) than that of conventional group [(52.3 +/- 6.9) minutes]; the blood loss of improved group [(4.9 +/- 2.0) mL] was significantly less (t=-25.20, P=0.00) than that of conventional group [(40.7 +/- 7.1) mL]. The patients were followed up 2-3 years (mean, 29.9 months). The American Orthopaedic Foot and Ankle Society (AOFAS) score was 99.6 +/- 1.0 in improved group and was 98.4 +/- 3.0 in conventional group, showing no significant difference between 2 groups (t=1.66, P=0.10). Comparison with conventional open suture, modified percutaneous suture has some advantages, such as easy operation, less complications, rapid recovery of limb function, and so on. Modified percutaneous suture is one of the best choices for the treatment of acute closed Achilles tendon rupture.
Kerr, Natalie C
2011-12-01
Overcorrection of hypotropia subsequent to adjustable suture surgery following inferior rectus recession is undesirable, often resulting in persistent diplopia and reoperation. I hypothesized that overcorrection shift after suture adjustment may be unique to thyroid eye disease, and the use of a nonabsorbable suture may reduce the occurrence of overcorrection. A retrospective chart review of adult patients who had undergone eye muscle surgery with an adjustable suture technique was performed. Overcorrection shifts that occurred between the time of suture adjustment and 2 months postoperatively were examined. Descriptive statistics, linear regression, Anderson-Darling tests, generalized Pareto distributions, odds ratios, and Fisher tests were performed for two overcorrection shift thresholds (>2 and >5 prism diopters [PD]). Seventy-seven patients were found: 34 had thyroid eye disease and inferior rectus recession, 30 had no thyroid eye disease and inferior rectus recession, and 13 patients had thyroid eye disease and medial rectus recession. Eighteen cases exceeded the 2 PD threshold, and 12 exceeded the 5 PD threshold. Statistical analyses indicated that overcorrection was associated with thyroid eye disease (P=6.7E-06), inferior rectus surgery (P=6.7E-06), and absorbable sutures (>2 PD: OR=3.7, 95% CI=0.4-35.0, P=0.19; and >5 PD: OR=6.0, 95% CI=1.1-33.5, P=0.041). After unilateral muscle recession for hypotropia, overcorrection shifts are associated with thyroid eye disease, surgery of the inferior rectus, and use of absorbable sutures. Surgeons performing unilateral inferior rectus recession on adjustable suture in the setting of thyroid eye disease should consider using a nonabsorbable suture to reduce the incidence of postoperative overcorrection.
Kerr, Natalie C.
2011-01-01
Purpose Overcorrection of hypotropia subsequent to adjustable suture surgery following inferior rectus recession is undesirable, often resulting in persistent diplopia and reoperation. I hypothesized that overcorrection shift after suture adjustment may be unique to thyroid eye disease, and the use of a nonabsorbable suture may reduce the occurrence of overcorrection. Methods A retrospective chart review of adult patients who had undergone eye muscle surgery with an adjustable suture technique was performed. Overcorrection shifts that occurred between the time of suture adjustment and 2 months postoperatively were examined. Descriptive statistics, linear regression, Anderson-Darling tests, generalized Pareto distributions, odds ratios, and Fisher tests were performed for two overcorrection shift thresholds (>2 and >5 prism diopters [PD]). Results Seventy-seven patients were found: 34 had thyroid eye disease and inferior rectus recession, 30 had no thyroid eye disease and inferior rectus recession, and 13 patients had thyroid eye disease and medial rectus recession. Eighteen cases exceeded the 2 PD threshold, and 12 exceeded the 5 PD threshold. Statistical analyses indicated that overcorrection was associated with thyroid eye disease (P=6.7E-06), inferior rectus surgery (P=6.7E-06), and absorbable sutures (>2 PD: OR=3.7, 95% CI=0.4–35.0, P=0.19; and >5 PD: OR=6.0, 95% CI=1.1–33.5, P=0.041). Conclusions After unilateral muscle recession for hypotropia, overcorrection shifts are associated with thyroid eye disease, surgery of the inferior rectus, and use of absorbable sutures. Surgeons performing unilateral inferior rectus recession on adjustable suture in the setting of thyroid eye disease should consider using a nonabsorbable suture to reduce the incidence of postoperative overcorrection. PMID:22253487
Minimizing genital tract trauma and related pain following spontaneous vaginal birth.
Albers, Leah L; Borders, Noelle
2007-01-01
Genital tract trauma is common following vaginal childbirth, and perineal pain is a frequent symptom reported by new mothers. The following techniques and care measures are associated with lower rates of obstetric lacerations and related pain following spontaneous vaginal birth: antenatal perineal massage for nulliparous women, upright or lateral positions for birth, avoidance of Valsalva pushing, delayed pushing with epidural analgesia, avoidance of episiotomy, controlled delivery of the baby's head, use of Dexon (U.S. Surgical; Norwalk, CT) or Vicryl (Ethicon, Inc., Somerville, NJ) suture material, the "Fleming method" for suturing lacerations, and oral or rectal ibuprofen for perineal pain relief after delivery. Further research is warranted to determine the role of prenatal pelvic floor (Kegel) exercises, general exercise, and body mass index in reducing obstetric trauma, and also the role of pelvic floor and general exercise in pelvic floor recovery after childbirth.
Comparison of pharyngocutaneous fistula closure with and without bacterial cellulose in a rat model.
Demir, Berat; Sarı, Murat; Binnetoglu, Adem; Yumusakhuylu, Ali Cemal; Filinte, Deniz; Tekin, İshak Özel; Bağlam, Tekin; Batman, Abdullah Çağlar
2018-04-01
The present study aimed to compare the effects of bacterial cellulose used for closure of pharyngocutaneous fistulae, a complication of total laryngectomy, with those of primary sutures in a rat model. Thirty female Sprague-Dawley underwent experimental pharyngoesophagotomy and were grouped depending on the material used for pharyngocutaneous fistula closure: group I, which received primary sutures alone, group II, which received bacterial cellulose alone; and group III, which received both. After 7 days, the rats were sacrificed. Pharyngocutaneous fistula development was assessed, the gross wound was inspected, and histological examination was conducted. Pharyngocutaneous fistulae developed in 12 rats (41%) in all: 6 from group I (21%), 4 from group II (14%) and 2 from group III (7%). Fibroblast density and inflammatory cell infiltration were significantly greater in group III than group I. We concluded that bacterial cellulose may be useful for pharyngocutaneous fistula closure. Copyright © 2017 Elsevier B.V. All rights reserved.
The management of corneal trauma: advances in the past twenty-five years.
Macsai, M S
2000-09-01
Over the past quarter century, advances in our understanding of corneal anatomy, physiology, and wound healing have all played an integral role in the management of corneal trauma. As the etiologies of corneal trauma have changed, so has our understanding of the impact of injury on corneal function as it relates to visual rehabilitation. Numerous new classes of antibiotics, antiinflammatory agents, and tissue adhesives have emerged. Occlusive therapy has advanced from simple pressure patching bandage soft contact lenses and collagen shields. Surgical instrumentation, operating microscopes, viscoelastic substances, and suture materials have all improved the outcomes of corneal trauma repair. Improved understanding of the refractive properties of the cornea through topography and alternative suture techniques has helped us restore the natural corneal curvature and visual outcomes. Consequently, in the last quarter of this century our therapeutic approaches to cornea trauma, both medical and surgical, have improved.
Arch bar stabilization of endotracheal tubes in children with facial burns.
Perrotta, V J; Stern, J D; Lo, A K; Mitra, A
1995-01-01
Endotracheal tube stabilization in children with facial burns can be difficult. Several methods rely on straps or complex devices that apply undesirable pressure to the face, potentially destroying skin grafts and making wound care difficult. Techniques that rely on a single wire or suture can be unreliable. Presented here is the arch bar method of endotracheal tube stabilization, which appears to be free of these problems. This method employs a standard dental arch bar secured to four maxillary teeth with 24-gauge stainless steel wire. The endotracheal tube is anchored to the arch bar with two pieces of wire or suture material. The arch bar method of endotracheal tube stabilization was used on three patients in the burn center at St. Christopher's Hospital for Children. Wound care and successful skin grafting were performed without difficulty. No complications related to the arch bars occurred.
Evaluation of a novel technique for wound closure using a barbed suture.
Murtha, Amy P; Kaplan, Andrew L; Paglia, Michael J; Mills, Benjie B; Feldstein, Michael L; Ruff, Gregory L
2006-05-01
Suture knots present several disadvantages in wound closure, because they are tedious to tie and place ischemic demands on tissue. Bulky knots may be a nidus for infection, and they may extrude through skin weeks after surgery. Needle manipulations during knot-tying predispose the surgeon to glove perforation. A barbed suture was developed that is self-anchoring, requiring no knots or slack management for wound closure. The elimination of knot tying may have advantages over conventional wound closure methods. This prospective, randomized, controlled trial was designed to show that the use of barbed suture in dermal closure of the Pfannenstiel incision during nonemergent cesarean delivery surgery produces scar cosmesis at 5 weeks that is no worse than that observed with conventional closure using 3-0 polydioxanone suture. Cosmesis was assessed by review of postoperative photographs by a blinded, independent plastic surgeon using the modified Hollander cosmesis score. Secondary endpoints included infection, dehiscence, pain, closure time, and other adverse events. The study enrolled 195 patients, of whom 188 were eligible for analysis. Cosmesis scores did not significantly differ between the barbed suture group and the control group. Rates of infection, dehiscence, and other adverse events did not significantly differ between the two groups. Closure time and pain scores were comparable between the groups. The barbed suture represents an innovative option for wound closure. With a cosmesis and safety profile that is similar to that of conventional suture technique, it avoids the drawbacks inherent to suture knots.
Progressive Tightening of Pulley Sutures for Primary Repair of Large Scalp Wounds
McLaughlin, Jillian M.; Ross, Lindy S.; Phillips, Linda G.; Wagner, Richard F.
2017-01-01
Summary: Scalp defects greater than 2 cm in diameter are not usually amenable to primary closure and require local tissue rearrangement, grafting, tissue expansion, or prolonged second intention healing. Scalp flap reconstruction is a significant undertaking that requires elevation of a total flap surface area that is 3–6 times the size of the defect, often involves profuse bleeding, and can be challenging to perform without conscious sedation or general anesthesia. Anticoagulated and medically complex patients pose additional challenges and limit options for treatment. The pulley suture uses the mechanical advantage of the pulley to distribute tension across a wound and is useful in areas of high tension such as scalp wounds. For scalp wounds greater than 2 cm, pulley sutures are placed along the length of the wound. An assistant exerts equal tension on the pulley sutures, and the surgeon sequentially ties the sutures. The sutures are tightened and retied weekly until complete scalp closure is achieved. The pulley sutures can be used for rapid primary closure of scalp wounds up to 2.5–3.0 cm in diameter under local anesthesia. For scalp wounds larger than 3 cm, we have also found that pulley sutures can be progressively tightened yielding additional tissue expansion every week. Scalp wounds greater than 3.0 cm can be easily closed via primary repair and weekly tightening of pulley sutures without the need for flap reconstruction, traditional tissue expander placement, or second intention healing. PMID:29632771
Bridge Suture for Successful McDonald Emergency Cerclage.
Tanaka, Masaaki; Hori, Yoshiaki; Shirafuji, Aya; Kato, Mitsunori; Kato, Jyun; Kobayashi, Hiroto; Tsuchida, Toru; Fukae, Tsukasa
2017-01-01
To create awareness about a surgical technique termed bridge suture, which is performed as a pretreatment before a McDonald cerclage is performed on an emergency to treat severe cervical insufficiency. Procedures for bridge suture were reviewed in detail and outcomes of 16 patients treated with bridge suture followed by McDonald cerclage were evaluated retrospectively. Using the bridge suture, the edges of uterine cervix were temporarily sutured and the external uterine os was closed, while the hourglass-shaped fetal membranes were concomitantly confined within the cervix; subsequently, a McDonald cerclage was performed. Over a 22-year period, 16 patients with a dilated cervix and bulging fetal membranes were treated using the technique of bridge suture followed by an emergency cerclage. The mean gestational age at cerclage was 22.5 weeks; the mean gestational age at delivery was 30.7 weeks; and the mean interval between cerclage and delivery was 8.2 weeks. In 15 out of 16 cases, cerclage was performed without encountering any complications. No maternal complications, including cervical laceration, were observed. The mean body weight of 17 neonates, including that of a twin, was 1,516 g and of them, 15 neonates survived. The important outcome of bridge suture is the replacement of fetal membranes back into the uterine cavity before McDonald's cerclage is performed. Pretreatment with bridge suture may facilitate the performance of a successful emergency cerclage and contribute to good maternal and neonatal outcomes. © 2016 S. Karger AG, Basel.
Agahi, Afshin; Harle, Robin
2009-08-01
Laparoscopic adjustable gastric banding (LAGB) is a widely performed surgical procedure for the treatment of morbid obesity. LAGB complications have declined since its development in the early 1990s. However, LAGB complications are still occurring and can sometimes be serious and life threatening. These complications are related either to the band or to the access port, such as band slippage or tubing disconnection, retrospectively. We report a rare case of bowel obstruction due to caecal volvulus caused by connecting tube used in LAP-BAND system in a bariatric operation, which obstructed a caecal loop, in a female who had undergone LAGB 2 years previously. Diagnosis of bowel obstruction was established with plain abdominal radiograph appearances. Follow-up abdominal computed tomography findings confirmed the diagnosis of caecal obstruction and revealed the underlying cause for this obstruction. Surgery was performed, and intraoperative examination demonstrated that connecting tube of the LAP-BAND system was a main causative factor. We can hypothesize that bowel obstruction secondary to LAGB operation may become frequently diagnosed as more LAGB operations performed worldwide. The emergence of many problems, such as this, can be minimized with enhancement in the development of better surgical materials, proper operative technique, and close postoperative management and follow-up.
Esophageal healing in the pony: comparison of sutured vs nonsutured esophagotomy.
Stick, J A; Krehbiel, J D; Kunze, D J; Wortman, J A
1981-09-01
Esophageal healing was evaluated in 10 ponies after sutured and nonsutured cervical esophagotomy techniques. Mucosal healing occurred significantly (P less than 0.005) faster after sutured esophagotomies (x = 7.5 days after surgery) than after nonsutured esophagotomies (x = 25.6 days after surgery), based on endoscopic and clinical evaluations. Although endoscopy was an accurate assessment of the return of normal passage of a food bolus through the esophagus, 4 of 10 ponies had radiographic evidence of a sinus tract after the mucosa was considered healed, based on endoscopic and clinical examinations. The surgical skin wound also healed significantly sooner after sutured esophagotomies (x = 10 days) than after nonsutured esophagotomies (x = 33.4 days). A traction diverticulum developed in all ponies with nonsutured esophagotomies, but occurred in only 1 pony with sutured esophagotomy. Minor complications were seen more frequently with sutured esophagotomy than with a nonsutured esophagotomy, but were resolved with local therapy. Saliva appeared to inhibit wound healing. All ponies were fed through esophagostomy tubes until the mucosa at the esophagotomy site was considered healed. Except for 1 sutured esophagotomy that dehisced, sutured esophagotomy was superior to nonsutured esophagotomy, because earlier establishment of a mucosal seal resulted in more rapid healing and reduced nursing care.
Sleiman, Z.; Tanos, V.; Van Belle, Y.; Carvalho, J.L.; Campo, R.
2015-01-01
The efficiency of suturing training and testing (SUTT) model by laparoscopy was evaluated, measuring the suturingskill acquisition of trainee gynecologists at the beginning and at the end of a teaching course. During a workshop organized by the European Academy of Gynecological Surgery (EAGS), 25 participants with three different experience levels in laparoscopy (minor, intermediate and major) performed the 4 exercises of the SUTT model (Ex 1: both hands stitching and continuous suturing, Ex 2: right hand stitching and intracorporeal knotting, Ex 3: left hand stitching and intracorporeal knotting, Ex 4: dominant hand stitching, tissue approximation and intracorporeal knotting). The time needed to perform the exercises is recorded for each trainee and group and statistical analysis used to note the differences. Overall, all trainees achieved significant improvement in suturing time (p < 0.005) as measured before and after completion of the training. Similar significantly improved suturing time differences (p < 0.005) were noted among the groups of trainees with different laparoscopic experience. In conclusion a short well-guided training course, using the SUTT model, improves significantly surgeon’s laparoscopic suturing ability, independently of the level of experience in laparoscopic surgery. Key words: Endoscopy, laparoscopic suturing, psychomotor skills, surgery, teaching, training suturing model. PMID:26977264
Mechanical properties of commercially available nylon sutures in the United States.
Callahan, Travis L; Lear, William; Kruzic, Jamie J; Maughan, Cory B
2017-05-01
Surgeons can choose from a wide selection of commercially available suture brands, which come at a range of prices. There is currently limited evidence in the literature to guide this selection process. This investigation examined the breaking force, stress, and elongation of a variety of commercially available nylon sutures compared to their relative prices. Seven 5-0, nonabsorbable, nylon suture brands were tensile tested in straight, knotted and knot-security configurations according to the procedures outlined by the United States Pharmacopeia for the tensile testing of sutures. Covidien, the cheapest brand tested, had the highest failure load of straight and knot-security tests. Dafilon was found to have the highest breaking force and percent elongation of knot-pull tests. J&J Ethicon and Supramid had the highest percent elongation to failure for straight-pull and knot-security tests, respectively. This study was limited to specific in vitro tensile properties of nylon suture. Other factors affecting suture quality and price, such as needle properties, were not investigated. The data presented in the study provide information for guiding the selection and purchase of sutures according to tensile properties. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 815-819, 2017. © 2016 Wiley Periodicals, Inc.
Wei, Zhuang; Thoreson, Andrew R.; Amadio, Peter C.; An, Kai-Nan; Zhao, Chunfeng
2014-01-01
We compared the mechanical force of tendon-to-bone repair techniques for flexor tendon reconstruction. Thirty-six flexor digitorum profundus (FDP) tendons were divided into three groups based upon the repair technique: (1) suture/button repair using FDP tendon (Pullout button group), (2) suture bony anchor using FDP tendon (Suture anchor group), and (3) suture/button repair using FDP tendon with its bony attachment preserved (Bony attachment group). The repair failure force and stiffness were measured. The mean load to failure and stiffness in the bony attachment group were significantly higher than that in the pullout button and suture anchor groups. No significant difference was found in failure force and stiffness between the pullout button and suture anchor groups. An intrasynovial flexor tendon graft with its bony attachment has significantly improved tensile properties at the distal repair site when compared with a typical tendon-to-bone attachment with a button or suture anchor. The improvement in the tensile properties at the repair site may facilitate postoperative rehabilitation and reduce the risk of graft rupture. PMID:23754507
Hahn, Wolfram; Fricke-Zech, Susanne; Fialka-Fricke, Julia; Dullin, Christian; Zapf, Antonia; Gruber, Rudolf; Sennhenn-kirchner, Sabine; Kubein-Meesenburg, Dietmar; Sadat-Khonsari, Reza
2009-09-01
An investigation was conducted to compare the image quality of prototype flat-panel volume computed tomography (fpVCT) and multislice computed tomography (MSCT) of suture structures. Bone samples were taken from the midpalatal suture of 5 young (16 weeks) and 5 old (200 weeks) Sus scrofa domestica and fixed in formalin solution. An fpVCT prototype and an MSCT were used to obtain images of the specimens. The facial reformations were assessed by 4 observers using a 1 (excellent) to 5 (poor) rating scale for the weighted criteria visualization of the suture structure. A linear mixed model was used for statistical analysis. Results with P < .05 were considered to be statistically significant. The visualization of the suture of young specimens was significantly better than that of older animals (P < .001). The visualization of the suture with fpVCT was significantly better than that with MSCT (P < .001). Compared with MSCT, fpVCT produces superior results in the visualization of the midpalatal suture in a Sus scrofa domestica model.
Moon, Hye-Sung
2018-06-01
Using the da Vinci single-site platform, surgeons can perform more minimally invasive surgery. However, surgical challenges exist due to the limitations of single-site instrumental movements. To aid in the performance of successful robotic single-site hysterectomy, a new suturing technique using the current set of limited instruments is introduced in this study. New vaginal cuff suturing techniques have been used in 55 robotic single-site hysterectomies in our institute over the past 2 years. A needle driver approach utilizing screwing and advancing the needle driver in the correct direction at an increasing angle from the transverse cuff margin with dragging and formation of an adequate loop of thread was used when suturing the vaginal cuff. Using the new vaginal suturing techniques, easy and firm vaginal cuff closure with reduced operative time relative to previous hysterectomies was achieved. The new vaginal cuff suturing techniques may convince more surgeons to perform robotic single-site hysterectomies more frequently and with greater ease. Copyright © 2018. Published by Elsevier B.V.
Onay, Ulaş; Akpınar, Sercan; Akgün, Rahmi Can; Balçık, Cenk; Tuncay, Ismail Cengiz
2013-01-01
The aim of this study was to compare new knotless single-row and double-row suture anchor techniques with traditional transosseous suture techniques for different sized rotator cuff tears in an animal model. The study included 56 cadaveric sheep shoulders. Supraspinatus cuff tears of 1 cm repaired with new knotless single-row suture anchor technique and supraspinatus and infraspinatus rotator cuff tears of 3 cm repaired with double-row suture anchor technique were compared to traditional transosseous suture techniques and control groups. The repaired tendons were loaded with 5 mm/min static velocity with 2.5 kgN load cell in Instron 8874 machine until the repair failure. The 1 cm transosseous group was statistically superior to 1 cm control group (p=0.021, p<0.05) and the 3 cm SpeedBridge group was statistically superior to the 1 cm SpeedFix group (p=0.012, p<0.05). The differences between the other groups were not statistically significant. No significant difference was found between the new knotless suture anchor techniques and traditional transosseous suture techniques.
Identification and dynamics of a cryptic suture zone in tropical rainforest
Moritz, C.; Hoskin, C.J.; MacKenzie, J.B.; Phillips, B.L.; Tonione, M.; Silva, N.; VanDerWal, J.; Williams, S.E.; Graham, C.H.
2009-01-01
Suture zones, shared regions of secondary contact between long-isolated lineages, are natural laboratories for studying divergence and speciation. For tropical rainforest, the existence of suture zones and their significance for speciation has been controversial. Using comparative phylogeographic evidence, we locate a morphologically cryptic suture zone in the Australian Wet Tropics rainforest. Fourteen out of 18 contacts involve morphologically cryptic phylogeographic lineages, with mtDNA sequence divergences ranging from 2 to 15 per cent. Contact zones are significantly clustered in a suture zone located between two major Quaternary refugia. Within this area, there is a trend for secondary contacts to occur in regions with low environmental suitability relative to both adjacent refugia and, by inference, the parental lineages. The extent and form of reproductive isolation among interacting lineages varies across species, ranging from random admixture to speciation, in one case via reinforcement. Comparative phylogeographic studies, combined with environmental analysis at a fine-scale and across varying climates, can generate new insights into suture zone formation and to diversification processes in species-rich tropical rainforests. As arenas for evolutionary experimentation, suture zones merit special attention for conservation. PMID:19203915
NASA Astrophysics Data System (ADS)
Bukreeva, Ekaterina B.; Bulanova, Anna A.; Kistenev, Yurii V.; Kuzmin, Dmitry A.; Tuzikov, Sergei A.; Yumov, Evgenii L.
2013-02-01
It is important to identify patients with chronic obstructive pulmonary disease (COPD) and lung cancer in the early stages of the disease. The method of laser opto-acoustic gas analysis, in this case, can act as a promising tool for diagnostics. The material for this study were the gas emission samples collected from patients and healthy volunteers - samples of exhaled air, swabs from teeth and cheeks. A set of material was formed three groups: healthy volunteers, patients with COPD, lung cancer patients. The resulting samples were analyzed by means of laser opto-acoustic gas analyzers: with intracavity location detector (ILPA-1), with extracavity location detector (LGA-2). Presentation of the results in an easy to visual form was performed using the method of elastic maps, based on the principal component analysis. The results of analysis show potentialities of usage of laser optoacoustic spectroscopy application to assess the status of patients with chronic obstructive pulmonary disease and lung cancer.
Sequential lift and suture technique for post-LASIK corneal striae.
Mackool, Richard J; Monsanto, Vivian R
2003-04-01
We describe a surgical technique to manage persistent corneal striae after laser in situ keratomileusis (LASIK). The sequential lift and suture technique reduces the time required for LASIK, eliminates the need to fixate the flap with forceps during suturing, and increases the accuracy of suture placement. The results in 10 eyes (9 patients) showed complete resolution of striae with improvement in subjective symptoms (glare and blurred vision) and best corrected visual acuity.
Cho, Jin Ho
2012-06-01
In cases with root tear of the medial meniscus posterior horn, the meniscus usually can be repaired by a pull out suture technique. However, there is difficulty in manipulating a suture hook via the anteromedial portal and looking through the arthroscopic camera via anterolateral portal in the narrow medial joint space at the same time. This article describes a modified simple pull out suture technique for root tear of the medial meniscus posterior horn using a posteromedial portal that provides a safe and easy handling of the suture hook. Our indications of this technique used in patients with Outerbridge 1-2 arthritic change and minimal varus axis change. Benefits of this technique are simple, less invasive, and reduced operation time by simultaneous suture with a hook via posteromedial portal and pulling of a string with grasper. It may reduce the possibility of an additional chondral or meniscal injury.
Ectocranial suture closure in Pan troglodytes and Gorilla gorilla: pattern and phylogeny.
Cray, James; Meindl, Richard S; Sherwood, Chet C; Lovejoy, C Owen
2008-08-01
The order in which ectocranial sutures undergo fusion displays species-specific variation among primates. However, the precise relationship between suture closure and phylogenetic affinities is poorly understood. In this study, we used Guttman Scaling to determine if the modal progression of suture closure differs among Homo sapiens, Pan troglodytes, and Gorilla gorilla. Because DNA sequence homologies strongly suggest that P. troglodytes and Homo sapiens share a more recent common ancestor than either does with G. gorilla, we hypothesized that this phylogenetic relationship would be reflected in the suture closure patterns of these three taxa. Results indicated that while all three species do share a similar lateral-anterior closure pattern, G. gorilla exhibits a unique vault pattern, which, unlike humans and P. troglodytes, follows a strong posterior-to-anterior gradient. P. troglodytes is therefore more like Homo sapiens in suture synostosis. Copyright 2008 Wiley-Liss, Inc.
[Intrauterine intestinal volvulus].
Gawrych, Elzbieta; Chojnacka, Hanna; Wegrzynowski, Jerzy; Rajewska, Justyna
2009-07-01
Intrauterine intestinal volvulus is an extremely rare case of acute congenital intestinal obstruction. The diagnosis is usually possible in the third trimester of a pregnancy. Fetal midgut volvulus is most likely to be recognized by observing a typical clockwise whirlpool sign during color Doppler investigation. Multiple dilated intestinal loops with fluid levels are usually visible during the antenatal ultrasound as well. Physical and radiographic findings in the newborn indicate intestinal obstruction and an emergency surgery is required. The authors describe intrauterine volvulus in 3 female newborns in which surgical treatment was individualized. The decision about primary or delayed anastomosis after resection of the gangrenous part of the small bowel was made at the time of the surgery and depended on the general condition of the newborn, as well as presence or absence of meconium peritonitis. Double loop jejunostomy was performed in case of two newborns, followed by a delayed end-to-end anastomosis. In case of the third newborn, good blood supply of the small intestine after untwisting and 0.25% lignocaine injections into mesentery led to the assumption that the torsion was not complete and ischemia was reversible. In the two cases of incomplete rotation the cecum was sutured to the left abdominal wall to prevent further twisting. The postoperative course was uneventful and oral alimentation caused no problems. Physical development of all these children has been normal (current age: 1-2 years) and the parents have not observed any disorders or problems regarding passage of food through the alimentary canal. Prompt antenatal diagnosis of this surgical emergency and adequate choice of intervention may greatly reduce mortality due to intrauterine volvulus.
Minimally invasive fluoroscopic percutaneous peritoneal dialysis catheter salvage.
Narayan, Rajeev; Fried, Terrance; Chica, Gerardo; Schaefer, Mathew; Mullins, Daniel
2014-06-01
Peritoneal dialysis catheter (PDC) dysfunction can often be treated fluoroscopically by manipulation with wire, balloon or stiff stylet, saving surgical intervention for refractory cases. We describe an enhanced percutaneous approach to PDC salvage that can lead to a more definitive intervention and salvage for cases refractory to fluoroscopic manipulation. In five cases of PD catheter malfunction, the deep cuff was dissected free after a 0.035 hydrophilic wire was passed into the peritoneum through the PDC. Only the intraperitoneal portion of the PDC was explanted. The PDC was cleared of obstruction and omentum. The intraperitoneal portion of the PDC was reimplanted over wire via a peel-away sheath and the deep cuff sutured. Omental entrapment was present in three of five patients and fibrin occlusion in four of the five cases. All catheters were repaired successfully by the described technique. Post procedure, 3-5 days of lower volume, recumbent PD exchanges were performed prior to full-dose PD. No perioperative complications or leaks were noted. All PDCs were patent at 6 months. One patient required laparoscopy for recurrent omental wrapping 3 months post intervention. PDC salvage in this manner is a cost-effective alternative to laparoscopic repair of PDCs failing catheter manipulation. The infection barrier afforded by the original superficial cuff and subcutaneous tunnel is maintained. PD can be resumed immediately. Only refractory cases need laparoscopy. This procedure allows for a more definitive correction of catheter migration and obstruction, avoids placement of a new PDC or temporary hemodialysis, is cost-effective and expands percutaneous options for dysfunctional PD catheters.
Cantarella, Daniele; Dominguez-Mompell, Ramon; Mallya, Sanjay M; Moschik, Christoph; Pan, Hsin Chuan; Miller, Joseph; Moon, Won
2017-11-01
Mini-implant-assisted rapid palatal expansion (MARPE) appliances have been developed with the aim to enhance the orthopedic effect induced by rapid maxillary expansion (RME). Maxillary Skeletal Expander (MSE) is a particular type of MARPE appliance characterized by the presence of four mini-implants positioned in the posterior part of the palate with bi-cortical engagement. The aim of the present study is to evaluate the MSE effects on the midpalatal and pterygopalatine sutures in late adolescents, using high-resolution CBCT. Specific aims are to define the magnitude and sagittal parallelism of midpalatal suture opening, to measure the extent of transverse asymmetry of split, and to illustrate the possibility of splitting the pterygopalatine suture. Fifteen subjects (mean age of 17.2 years; range, 13.9-26.2 years) were treated with MSE. Pre- and post-treatment CBCT exams were taken and superimposed. A novel methodology based on three new reference planes was utilized to analyze the sutural changes. Parameters were compared from pre- to post-treatment and between genders non-parametrically using the Wilcoxon sign rank test. For the frequency of openings in the lower part of the pterygopalatine suture, the Fisher's exact test was used. Regarding the magnitude of midpalatal suture opening, the split at anterior nasal spine (ANS) and at posterior nasal spine (PNS) was 4.8 and 4.3 mm, respectively. The amount of split at PNS was 90% of that at ANS, showing that the opening of the midpalatal suture was almost perfectly parallel antero-posteriorly. On average, one half of the anterior nasal spine (ANS) moved more than the contralateral one by 1.1 mm. Openings between the lateral and medial plates of the pterygoid process were detectable in 53% of the sutures (P < 0.05). No significant differences were found in the magnitude and frequency of suture opening between males and females. Correlation between age and suture opening was negligible (R 2 range, 0.3-4.2%). Midpalatal suture was successfully split by MSE in late adolescents, and the opening was almost perfectly parallel in a sagittal direction. Regarding the extent of transverse asymmetry of the split, on average one half of ANS moved more than the contralateral one by 1.1 mm. Pterygopalatine suture was split in its lower region by MSE, as the pyramidal process was pulled out from the pterygoid process. Patient gender and age had a negligible influence on suture opening for the age group considered in the study.
Sarhan, A; Dua, H.; Beach, M.
2000-01-01
BACKGROUND/AIMS—Post-keratoplasty astigmatism can be managed by selective suture removal in the steep axis. Corneal topography, keratometry, and refraction are used to determine the steep axis for suture removal. However, often there is a disagreement between the topographically determined steep axis and sutures to be removed and that determined by keratometry and refraction. The purpose of this study was to evaluate any difference in the effect of suture removal, on visual acuity and astigmatism, in patients where such a disagreement existed. METHODS—37 cases (from 37 patients) of selective suture removal after penetrating keratoplasty, were included. In the first group "the disagreement group" (n=15) there was disagreement between corneal topography, keratometry, and refraction regarding the axis of astigmatism and sutures to be removed. In the second group "the agreement group" (n=22) there was agreement between corneal topography, keratometry, and refraction in the determination of the astigmatic axis and sutures to be removed. Sutures were removed according to the corneal topography, at least 5 months postoperatively. Vector analysis for change in astigmatism and visual acuity after suture removal was compared between groups. RESULTS—In the disagreement group, the amount of vector corrected change in refractive, keratometric, and topographic astigmatism after suture removal was 3.45 (SD 2.34), 3.57 (1.63), and 2.83 (1.68) dioptres, respectively. In the agreement group, the amount of vector corrected change in refractive, keratometric, and topographic astigmatism was 5.95 (3.52), 5.37 (3.29), and 4.71 (2.69) dioptres respectively. This difference in the vector corrected change in astigmatism between groups was statistically significant, p values of 0.02, 0.03, and 0.03 respectively. Visual acuity changes were more favourable in the agreement group. Improvement or no change in visual acuity occurred in 90.9% in the agreement group compared with 73.3% of the disagreement group. CONCLUSIONS—Agreement between refraction, keratometry, and topography was associated with greater change in vector corrected astigmatism and was an indicator of good prognosis. Disagreement between refraction, keratometry, and topography was associated with less vector corrected change in astigmatism, a greater probability of decrease in visual acuity, and a relatively poor outcome following suture removal. However, patients in the disagreement group still have a greater chance of improvement than worsening, following suture removal. PMID:10906087
Delye, Hans; Clijmans, Tim; Mommaerts, Maurice Yves; Sloten, Jos Vnder; Goffin, Jan
2015-12-01
Finite element models (FEMs) of the head are used to study the biomechanics of traumatic brain injury and depend heavily on the use of accurate material properties and head geometry. Any FEM aimed at investigating traumatic head injury in children should therefore use age-specific dimensions of the head, as well as age-specific material properties of the different tissues. In this study, the authors built a database of age-corrected skull geometry, skull thickness, and bone density of the developing skull to aid in the development of an age-specific FEM of a child's head. Such a database, containing age-corrected normative skull geometry data, can also be used for preoperative surgical planning and postoperative long-term follow-up of craniosynostosis surgery results. Computed tomography data were processed for 187 patients (age range 0-20 years old). A 3D surface model was calculated from segmented skull surfaces. Skull models, reference points, and sutures were processed into a MATLAB-supported database. This process included automatic calculation of 2D measurements as well as 3D measurements: length of the coronal suture, length of the lambdoid suture, and the 3D anterior-posterior length, defined as the sum of the metopic and sagittal suture. Skull thickness and skull bone density calculations were included. Cephalic length, cephalic width, intercoronal distance, lateral orbital distance, intertemporal distance, and 3D measurements were obtained, confirming the well-established general growth pattern of the skull. Skull thickness increases rapidly in the first year of life, slowing down during the second year of life, while skull density increases with a fast but steady pace during the first 3 years of life. Both skull thickness and density continue to increase up to adulthood. This is the first report of normative data on 2D and 3D measurements, skull bone thickness, and skull bone density for children aged 0-20 years. This database can help build an age-specific FEM of a child's head. It can also help to tailor preoperative virtual planning in craniosynostosis surgery toward patient-specific normative target values and to perform objective long-term follow-up in craniosynostosis surgery.
Crisp, Catrina C; Herfel, Charles V; Pauls, Rachel N; Westermann, Lauren B; Kleeman, Steven D
2016-01-01
This study aimed to characterize pertinent anatomy relative to the sacral suture placed at time of robotic sacrocolpopexy using postoperative computed tomography and magnetic resonance imaging. A vascular clip was placed at the base of the sacral suture at the time of robotic sacrocolpopexy. Six weeks postoperatively, subjects returned for a computed tomography scan and magnetic resonance imaging. Ten subjects completed the study. The middle sacral artery and vein coursed midline or to the left of midline in all the subjects. The left common iliac vein was an average of 26 mm from the sacral suture. To the right of the suture, the right common iliac artery was 18 mm away. Following the right common iliac artery to its bifurcation, the right internal iliac was on average 10 mm from the suture. The bifurcations of the inferior vena cava and the aorta were 33 mm and 54 mm further cephalad, respectively.The right ureter, on average, was 18 mm from the suture. The thickness of the anterior longitudinal ligament was 2 mm.The mean angle of descent of the sacrum was 70 degrees. Lastly, we found that 70% of the time, a vertebral body was directly below the suture; the disc was noted in 30%. We describe critical anatomy surrounding the sacral suture placed during robotic sacrocolpopexy. Proximity of both vascular and urologic structures within 10 to 18 mm, as well as anterior ligament thickness of only 2 mm highlights the importance of adequate exposure, careful dissection, and surgeon expertise.
Contact area and pressure in suture bridge rotator cuff repair using knotless lateral anchors.
Tompkins, Marc; Monchik, Keith O; Plante, Matthew J; Fleming, Braden C; Fadale, Paul D
2011-10-01
To evaluate whether the use of knotless lateral anchors in a suture bridge construct produces better contact area and pressure parameters than a suture bridge construct with standard lateral anchors that require knots or a double-row repair. The hypothesis was that knotless lateral anchors would produce better contact area and pressure parameters than the other two constructs. A total of fifteen matched pairs of cadaveric shoulders were divided into three groups. In Group 1, a suture bridge using knotless anchors for the lateral row was performed on five shoulders. A suture bridge using standard lateral row anchors that require knots was performed on the contralateral shoulders. In Group 2, suture bridge with knotless lateral row anchors was compared with double-row repair. In Group 3, suture bridge using standard lateral row anchors was compared with double-row repair. The contact conditions of the rotator cuff footprint were measured using pressure-sensitive film. There were no statistically significant differences between any of the techniques regarding contact area F(2, 15.7) = 3.09, P = 0.07 or mean contact pressure F(2, 15.1) = 2.35, P = 0.12. A post hoc power analysis suggests differences between techniques are likely less than 91-113 mm(2) for area and 0.071-0.089 N for pressure. The use of knotless anchors in the lateral row of a suture bridge repair did not increase the footprint contact area or contact pressure when compared to a suture bridge repair requiring knots laterally or to a double-row repair.
Comparison of holding strength of suture anchors for hepatic and renal parenchyma.
Ames, Caroline D; Perrone, Juan M; Frisella, Alison J; Morrissey, Kevin; Landman, Jaime
2005-12-01
Various laparoscopic devices have been described for suture anchoring during solidorgan parenchymal closure. Application of these devices expedites the closure of parenchymal defects and minimizes ischemia time. We compared different technologies as suture anchors for parenchymal closure. A tensometer was used to determine the amount of tension necessary to dislodge each of five different clips from Vicryl suture alone or against two different substrates (fresh pig kidney and liver) with and without an intervening pledget. The clips investigated were the Lapra-Ty (Ethicon), Endoclip II (US Surgical), small Horizon Ligating Clips (Weck), Hem-o-lok Medium Polymer Clips (Week), and a novel Suture-clip (Applied Medical). ANOVA and two-sided Fisher's exact test provided statistical analysis. The force required to dislodge the Lapra-Ty clip from bare suture for both 0 and 1 Vicryl (7.0 N) was approximately fourfold the force required to dislodge the Endoclips or the 5-mm or 10-mm Hem-o-lok clips (p<0.01). When clips were applied to suture running through renal or liver parenchyma, the novel Suture-clip required the greatest tension to dislodge (P<0.01), followed by the Horizon and Lapra-Ty clips. There were no statistically significant differences in the tension required to dislodge a given clip from the two parenchymal substrates or in the presence or absence of a pledget. In our experimental model, the Suture-clip, Lapra-Ty, and Horizon clips required significantly greater tension to dislodge than the Hem-o-lok and Endoclip clips. The addition of a pledget did not improve tension resistance.
Stretch force guides finger-like pattern of bone formation in suture
Kou, Xiao-Xing; Zhang, Ci; Zhang, Yi-Mei; Cui, Zhen; Wang, Xue-Dong; Liu, Yan; Liu, Da-Wei; Zhou, Yan-Heng
2017-01-01
Mechanical tension is widely applied on the suture to modulate the growth of craniofacial bones. Deeply understanding the features of bone formation in expanding sutures could help us to improve the outcomes of clinical treatment and avoid some side effects. Although there are reports that have uncovered some biological characteristics, the regular pattern of sutural bone formation in response to expansion forces is still unknown. Our study was to investigate the shape, arrangement and orientation of new bone formation in expanding sutures and explore related clinical implications. The premaxillary sutures of rat, which histologically resembles the sutures of human beings, became wider progressively under stretch force. Micro-CT detected new bones at day 3. Morphologically, these bones were forming in a finger-like pattern, projecting from the maxillae into the expanded sutures. There were about 4 finger-like bones appearing on the selected micro-CT sections at day 3 and this number increased to about 18 at day 7. The average length of these projections increased from 0.14 mm at day 3 to 0.81 mm at day 7. The volume of these bony protuberances increased to the highest level of 0.12 mm3 at day 7. HE staining demonstrated that these finger-like bones had thick bases connecting with the maxillae and thin fronts stretching into the expanded suture. Nasal sections had a higher frequency of finger-like bones occuring than the oral sections at day 3 and day 5. Masson-stained sections showed stretched fibers embedding into maxillary margins. Osteocalcin-positive osteoblasts changed their shapes from cuboidal to spindle and covered the surfaces of finger-like bones continuously. Alizarin red S and calcein deposited in the inner and outer layers of finger-like bones respectively, which showed that longer and larger bones formed on the nasal side of expanded sutures compared with the oral side. Interestingly, these finger-like bones were almost paralleling with the direction of stretch force. Inclined force led to inclined finger-like bones formation and deflection of bilateral maxillae. Additionally, heavily compressive force caused fracture of finger-like bones in the sutures. These data together proposed the special finger-like pattern of bone formation in sutures guided by stretch force, providing important implications for maxillary expansion. PMID:28472133
Effect of Adhesive Strips and Dermal Sutures vs Dermal Sutures Only on Wound Closure
Custis, Trenton; Armstrong, April W.; King, Thomas H.; Sharon, Victoria R.; Eisen, Daniel B.
2016-01-01
IMPORTANCE Although applying adhesive strips to a wound closure has been shown to have outcomes equivalent to those with cuticular suturing, it is unknown whether adhesive strips provide additional benefit compared with dermal suturing alone. OBJECTIVE To determine whether the addition of adhesive strips to a wound closed with buried interrupted subcuticular sutures improves outcomes following wound closure. DESIGN, SETTING, AND PARTICIPANTS A prospective, randomized split-wound intervention was conducted between November 14, 2013, and May 16, 2014, in patients who underwent cutaneous surgical procedures at the University of California, Davis, outpatient dermatology clinic. Fifty-seven patients 18 years or older with postoperative defects of at least 3 cm, resulting from either Mohs micrographic surgical procedures or surgical excision, were screened for participation. Nine patients were excluded and 48 were enrolled. INTERVENTIONS Half of each wound was randomized to receive buried interrupted subcuticular sutures and overlying adhesive strips and the other half received buried interrupted subcuticular sutures only. MAIN OUTCOMES AND MEASURES At 3 months’ follow-up, each patient and 2 blinded observers evaluated the wound using the Patient Observer Scar Assessment Scale. RESULTS The total mean (SD) Patient Observer Scar Assessment Scale score for observers for the side that received a combination of adhesive strips and buried interrupted subcuticular suturing (12.3 [4.8]) and the side that received sutures only (12.9 [6.3]) did not differ significantly at 3 months (P = .32). There was no significant difference in the total patient assessment scale score between the combination closure (14.0 [7.6]) and sutures only (14.7 [7.6]) sides at 3 months (P = .39). There was also no significant difference between the 2 closure methods in terms of mean (SD) scar width (both methods: 1.1 [0.8] mm, P = .89) at follow-up. CONCLUSIONS AND RELEVANCE Combination closure with adhesive strips and buried interrupted subcuticular suturing was not significantly associated with improved overall scar assessment compared with buried interrupted subcuticular suturing alone when evaluated by blinded observers or the patients themselves. Our results do not support the use of adhesive strips as a means to improve cosmetic outcomes or reduce scar width. TRIAL REGISTRATION clinicaltrials.gov Identifier: NCT01979497 PMID:25875131
Suture anchor repair of quadriceps tendon rupture after total knee arthroplasty.
Kim, Tae Won B; Kamath, Atul F; Israelite, Craig L
2011-08-01
Disruption of the extensor mechanism after total knee arthroplasty (TKA) is a devastating complication, usually requiring surgical repair. Although suture anchor fixation is well described for repair of the ruptured native knee quadriceps tendon, no study has discussed the use of suture anchors in quadriceps repair after TKA. We present an illustrative case of successful suture anchor fixation of the quadriceps mechanism after TKA. The procedure has been performed in a total of 3 patients. A surgical technique and brief review of the literature follows. Suture anchor fixation of the quadriceps tendon is a viable option in the setting of rupture after TKA. Copyright © 2011 Elsevier Inc. All rights reserved.
The posterior auricular muscle: a useful anatomical landmark for otoplasty.
Stephen, C; Lowrie, A G
2017-05-01
The correct anatomical placement of conchomastoid sutures during suture otoplasty can sometimes prove challenging. If the suture vector is inaccurate, reduction can be difficult and this may lead to malrotation of the pinna. This paper describes the adoption of the auricularis posterior muscle, which runs from the mastoid to the concha and whose function is to adduct the pinna, as a marker for conchomastoid suture placement. The muscle is easily identified and dissected, providing a landmark for the placement of sutures onto the adjacent concha and mastoid fascia. This allows for an anatomical reduction of the pinna. It is believed that this approach will prove useful to the otoplasty surgeon.
Molecular genetics of craniosynostosis
NASA Astrophysics Data System (ADS)
Caterine; Auerkari, Elza Ibrahim
2018-03-01
Tight regulation process and complex interplay occur along the osteogenic interfaces of the cranial sutures in normal growth and development of the skull. Cranial sutures serve as sites of bone growth while maintaining a state of patency to accommodate the developing brain. Cranial sutures are fibro-cellular structures that separate the rigid plates of the skull bones. Premature fusion of one or more cranial sutures leads to a condition known as craniosynostosis. Craniosynostosis is one of the most common craniofacial anomalies with a prevalence of 1 in 2,500 newborns. Several genes have been identified in the pathogenesis of craniosynostosis. Molecular signaling events and the intracellular signal transduction pathways implicated in the suture pathobiology will provide a useful approach for therapeutic targeting.
Zhang, Gang; Zhang, Fusheng; Zhu, Mei; Zhang, Wenlong; Fan, Quanxin; Zou, Chengwei; Wang, Anbiao
2011-10-01
Since 2008, 28 patients with congenital mitral regurgitation have undergone mitral valve repair with a modified edge-to-edge technique at our institution. The regurgitant mitral leaflet was sutured with a pledget-reinforced, horizontal mattress suture with No. 4-0 polypropylene on the ventricle side and a pledget-reinforced mattress suture with Gore-Tex sutures (W.L. Gore & Associates, Flagstaff, AZ) and Dacron pledgets (Chest, Shanghai) placed on the anterior and posterior annulus corresponding to the edge-to-edge suturing site. Early results are encouraging, but a longer follow-up is needed. Copyright © 2011 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Bacterial Adherence to High Tensile-Strength Sutures.
2011-06-01
8063/10238/$00.00 doi:10.1016/j.arthro.2011.02.003 834 Arthroscopy : The Journal of Arthroscopic and Related Surgery, Vol 27, No 6 (June), 2011: pp 834...Herbert MA, Coons DA, Boothby MH. Sutures and suture anchors—Update 2006. Arthroscopy 2006;22:1063- 1069. 2. Barber FA, Herbert MA, Beavis RC. Cyclic... Arthroscopy 2007;23:884-888. 5. Wust DM, Meyer DC, Favre P, Gerber C. Mechanical and handling properties of braided polyblend polyethylene sutures in
Use of adhesive surgical tape with the absorbable continuous subcuticular suture.
Kolt, Jeremy D
2003-08-01
The absorbable continuous subcuticular suture is frequently used to close surgical incisions where the aim is healing by primary intention. A form of adhesive surgical tape is commonly also placed over the wound but this combination closure seems to have its development based on anecdotal, rather than experimental evidence. The present study reviews the scientific literature on the development of sutureless wound closure and presents the current evidence for the use of combination wound closure. Review was undertaken of the medical literature using the PubMed Internet database and cross-referencing major -articles on the subject. The following combinations of key words were searched: skin closure, wound closure, suture technique, sutureless, adhesive tape, op-site, staples, subcuticular suture, complication, infection and scars. Taped closure alone has advantages of lower wound infection rates and greater wound tensile strength, but disadvantages of epidermal reaction, skin edge inversion, doubtful safety and time required for meticulous surgical technique. The use of the continuous absorbable subcuticular suture allows accurate skin edge approximation, which increases the safety margin. The combination closure has a slightly superior cosmetic result to sutureless techniques but no study has been performed to compare the results of combination subcuticular suture and tape, with tape or subcuticular suture alone. There is no evidence in the scientific literature to justify or support the practice of closing a surgical wound with both subcuticular suture and adhesive surgical tape.
Gonçalves, Antonio José; de Souza, J A L; Menezes, M B; Kavabata, N K; Suehara, A B; Lehn, C N
2009-11-01
The extension of the surgery and closure type of the pharynx can be the determinants in the pharyngocutaneous fistula development. The objective of the study is to evaluate the incidence of pharingocutaneous salivary fistulae after total laryngectomies comparing manual and mechanical sutures. The study is designed as non-randomized, prospective clinical study. Sixty patients with squamous cell carcinoma were submitted to total laryngectomies. In 30 cases, the linear stapler (75 mm) closure (surgical technique described in details) and in other 30 cases manual suture was used. The cases of mechanical suture were prospective and consecutive and the cases of manual suture were a review series of patients who underwent a manual suture of pharynx, in the same period of time. The statistical analysis between the two groups concluded that both were comparable. Fistulae incidence was 6.7% (2/30) in the group with the mechanical suture and 36.7% (11/30) in the group with manual suture closure, presenting a significant difference (p = 0.0047). The total laryngectomy with mechanical closure is an easy and fast learning technique, allowing watertight closure of the pharynx with a low risk of contamination of the surgical field. It is an assured method, even in previously irradiated patients, since we respect the limits of its indication regarding the extension of primary tumor that must be confirmed by previous suspension laryngectomy performed in the operating room.
Parikh, Punam P; Tashiro, Jun; Wagenaar, Amy E; Curbelo, Miosotys; Perez, Eduardo A; Neville, Holly L; Hogan, Anthony R; Sola, Juan E
2018-04-01
Appendiceal ligation during pediatric laparoscopic appendectomy (LA) may be performed using looped suture versus stapler. Controversy regarding the utility of either method exists. Clinical outcomes and cost analysis of LA with both methods were compared. All pediatric LA were performed from fiscal years 2013 and 2014 by two pediatric surgeons. While one surgeon used looped suture, the other used stapler exclusively. chi-Square tests were performed to analyze associations. Two hundred thirty-eight cases were analyzed where looped suture versus stapler LA was performed in 46% and 54% of patients, respectively. Operating room costs were $317.10 and $707.12/person for looped suture and stapler LA, respectively (P<0.0001). Difference in cost of $390.02/person was attributed solely to ligation type. On bivariate analysis, rate of in-hospital complications, length of stay, return-to-ER and readmission within 30 days did not significantly differ between groups. A comparative analysis of looped suture versus stapler device during LA for pediatric appendicitis revealed that postoperative complications, length of stay, ER visits and readmissions were not significantly different. Looped suture LA was significantly more cost efficient than stapler LA. In pediatric appendicitis, appendiceal ligation during LA may be performed safely and cost effectively with looped suture versus stapler. Cost effectiveness LEVEL OF EVIDENCE: III. Copyright © 2017 Elsevier Inc. All rights reserved.
Tamboli, Mallika; Mihata, Teruhisa; Hwang, James; McGarry, Michelle H; Kang, Yangmi; Lee, Thay Q
2014-03-01
We investigated the effects of bite-size horizontal mattress stitch (distance between the limbs passed through the tendon) on the biomechanical properties of the repaired tendon. We anchored 20 bovine Achilles tendons to bone using no. 2 high-strength suture and 5-mm titanium suture anchors in a mattress-suture technique. Tendons were allocated randomly into two groups of ten each to receive stitches with a 4- or 10-mm bite. Specimens underwent cyclic loading from 5 to 30 N at 1 mm/s for 30 cycles, followed by tensile testing to failure. Gap formation, tendon strain, hysteresis, stiffness, yield load, ultimate load, energy to yield load, and energy to ultimate load were compared between groups using unpaired t tests. The 4-mm group had less (p < 0.05) gap formation and less (p < 0.05) longitudinal strain than did the 10-mm group. Ultimate load (293.6 vs. 148.9 N) and energy to ultimate load (2,563 vs. 1,472 N-mm) were greater (p < 0.001) for the 10-mm group than the 4-mm group. All tendons repaired with 4-mm suturing failed at the suture-tendon interface, with sutures pulling through the tendon, whereas the suture itself failed before the tendon did in seven of the ten specimens in the 10-mm group. Whereas a 4-mm bite fixed the tendon more tightly but at the cost of decreased ultimate strength, a 10-mm bite conveyed greater ultimate strength but with increased gap and strain. These results suggest that for the conventional double-row repair, small mattress stitches provide a tighter repair, whereas large stitches are beneficial to prevent sutures from pulling through the tendon after surgery. For suture-bridge rotator cuff repair, large stitches are beneficial because the repaired tendon has a higher strength, and the slightly mobile medial knot can be tightened by lateral fixation.
Liu, Rui Wen; Lam, Patrick Hong; Shepherd, Henry M.; Murrell, George A. C.
2017-01-01
Background: Rotator cuff retears after surgical repair are associated with poorer subjective and objectives clinical outcomes than intact repairs. Purpose: The aims of this study were to (1) examine the biomechanical differences between rotator cuff repair using No. 2 suture and tape in an ovine model and (2) compare early clinical outcomes between patients who had rotator cuff repair with tape and patients who had repair with No. 2 suture. Study Design: Controlled laboratory study and cohort study; Level of evidence, 3. Methods: Biomechanical testing of footprint contact pressure and load to failure were conducted with 16 ovine shoulders using a tension band repair technique with 2 different types of sutures (No. 2 suture [FiberWire; Arthrex] and tape [FiberTape; Arthrex]) with the same knotless anchor system. A retrospective study of 150 consecutive patients (tape, n = 50; suture, n = 100) who underwent arthroscopic rotator cuff repair by a single surgeon with tear size larger than 1.5 × 1 cm was conducted. Ultrasound was used to evaluate the repair integrity at 6 months postsurgery. Results: Rotator cuff repair using tape had greater footprint contact pressure (mean ± standard error of the mean, 0.33 ± 0.03 vs 0.11 ± 0.3 MPa; P < .0001) compared with repair using No. 2 sutures at 0° abduction with a 30-N load applied across the repaired tendon. The ultimate failure load of the tape repair was greater than that for suture repair (217 ± 28 vs 144 ± 14 N; P < .05). The retear rate was similar between the tape (16%; 8/50) and suture groups (17%; 17/100). Conclusion: Rotator cuff repair with the wider tape compared with No. 2 suture did not affect the retear rate at 6 months postsurgery, despite having superior biomechanical properties. PMID:28451619
A new suturing instrument that allows the use of microsuture at laparoscopy.
McComb, P F
1992-04-01
A surgeon at University Hospital-Shaughnessy Site in Vancouver, British Columbia in Canada has used a new suturing instrument that enters the peritoneal cavity to permit microsutures of size 6-0 or less and 75 cm in length during laparoscopy. Surgeons can use this instrument to perform female sterilizations as well as removal of the gall gladder and appendix and repair of the bowel, bladder, and ureteric injuries. As of April 1992, the suturing instrument was not yet commercially available. It consists of a partial hollow 30 cm x 2 mm (inside diameter) tube with the end that does not enter the peritoneal cavity being occluded. The suturing instrument enters the peritoneal cavity via a standard 5 mm deflection valved trocar sleeve with a 3 mm reduction sleeve or with a 3 mm inside diameter occlusive rubber washer instead of the standard 5 mm washer. The suture must have sufficient tensile strength and have low coefficients for static and for sliding surface frictions. Once the suture and needle are inside the body, forceps which have entered via another cannula detach them from the suturing instrument. A 3 mm laproscopic needle driver replaces the suturing instrument at this point. The surgeon guides the needle through the intended tissues and then withdrawn with the needle driver through the 5 mm sleeve. The surgeon ties the knot outside the body and slides it down the length of the suture to apply it to the tissue. He/she repeats this 1 more time. Scissors inserted through the other opening then cut the suture. Once mastered, this process takes only a few minutes to complete. In all 11 cases or restoration of uterine tube patency done by the surgeon in Vancouver using the new technique, tubal patency has not been hindered. 2 assessed sterilization reversals have been successful.
Smith, Patrick A; Bozynski, Chantelle C; Kuroki, Keiichi; Henrich, Sarah M; Wijdicks, Coen A; Cook, James L
2018-05-31
The purpose of this study was to assess intra-articular use of a nonabsorbable braided suture tape for its biocompatibility when implanted adjacent to the native anterior cruciate ligament (ACL) in a canine model. Establishing biocompatibility of suture tape in the knee is an important foundational step for clinicians considering use of suture tape augmentation for ACL reconstruction or repair. The study hypothesis was that a nonabsorbable braided suture tape would be biocompatible in the knee with no resultant adverse functional consequences, and no significant intra-articular synovial reactions or articular cartilage degeneration attributable to direct exposure to the suture tape, whether intact or transected. Nonabsorbable braided suture tape was arthroscopically implanted adjacent to the native ACL of dogs ( n = 6). The suture was intact in half of the dogs and was transected in the other half as a "worst-case" scenario. Dogs were assessed for postoperative complications and morbidity. Arthroscopic grading of synovium and cartilage was performed at 4 and 6 months. Histologic assessments were performed at the 6-month endpoint and compared with the ACL partial tear ( n = 9) and ACL reconstruction ( n = 5) cohorts as well as historical sham controls. No postoperative complications were noted. No animal developed lameness or clinical dysfunction, and there were no severe inflammatory or immune responses, cartilage erosions, or premature osteoarthritis noted. Arthroscopic assessments revealed no to mild synovitis and no apparent cartilage damage in either group. Histologically, both the intact and transected suture tape groups were associated with significantly ( p ≤ 0.05) less synovial and articular cartilage pathology compared with the partial ACL transection and patellar bone-tendon-bone ACL autograft reconstruction cohorts, and matched historical sham controls. The hypothesis was accepted as study results support the biocompatibility of suture tape in the canine knee. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Suture repair of umbilical hernia during caesarean section: a case-control study.
Steinemann, D C; Limani, P; Ochsenbein, N; Krähenmann, F; Clavien, P-A; Zimmermann, R; Hahnloser, D
2013-08-01
The objective of this study was to investigate the additional burdens in terms of pain, prolongation of surgery and morbidity which is added to elective caesarean section if umbilical hernia suture repair is performed simultaneously. Secondly, patient's satisfaction and hernia recurrence rate were assessed. Consecutive women with symptomatic umbilical hernia undergoing internal or external suture repair during elective caesarean were included in this retrospective cohort-control study. Data on post-operative pain, duration of surgery and morbidity of a combined procedure were collected. These patients were matched 1:10 to women undergoing caesarean section only. Additionally, two subgroups were assessed separately: external and internal suture hernia repair. These subgroups were compared for patient's satisfaction, cosmesis, body image and recurrence rate. Fourteen patients with a mean age of 37 years were analysed. Internal suture repair (n = 7) prolonged caesarean section by 20 min (p = 0.001) and external suture repair (n = 7) by 34 min (p < 0.0001). Suture repair did not increase morphine use (0.38 ± 0.2 vs. 0.4 ± 02 mg/kg body weight), had no procedure-related morbidity and prolonged hospitalization by 0.5 days (p = 0.01). At a median follow-up of 37 (5-125) months, two recurrences in each surgical technique, internal and external suture repair, occurred (28 %). Body image and cosmesis score showed a higher level of functioning in internal suture repair (p = 0.02; p = 0.04). Despite a high recurrence rate, internal suture repair of a symptomatic umbilical hernia during elective caesarean section should be offered to women if requested. No additional morbidity or scar is added to caesarean section. Internal repair is faster, and cosmetic results are better, additional skin or fascia dissection is avoided, and it seems to be as effective as an external approach. Yet, women must be informed on the high recurrence rate.
Music experience influences laparoscopic skills performance.
Boyd, Tanner; Jung, Inkyung; Van Sickle, Kent; Schwesinger, Wayne; Michalek, Joel; Bingener, Juliane
2008-01-01
Music education affects the mathematical and visuo-spatial skills of school-age children. Visuo-spatial abilities have a significant effect on laparoscopic suturing performance. We hypothesize that prior music experience influences the performance of laparoscopic suturing tasks. Thirty novices observed a laparoscopic suturing task video. Each performed 3 timed suturing task trials. Demographics were recorded. A repeated measures linear mixed model was used to examine the effects of prior music experience on suturing task time. Twelve women and 18 men completed the tasks. When adjusted for video game experience, participants who currently played an instrument performed significantly faster than those who did not (P<0.001). The model showed a significant sex by instrument interaction. Men who had never played an instrument or were currently playing an instrument performed better than women in the same group (P=0.002 and P<0.001). There was no sex difference in the performance of participants who had played an instrument in the past (P=0.29). This study attempted to investigate the effect of music experience on the laparoscopic suturing abilities of surgical novices. The visuo-spatial abilities used in laparoscopic suturing may be enhanced in those involved in playing an instrument.
Assessment potential of a new suture simulator in laparoscopic surgical skills training.
Takeoka, Tomohira; Takiguchi, Shuji; Uemura, Munenori; Miyazaki, Yasuhiro; Takahashi, Tsuyoshi; Kurokawa, Yukinori; Makino, Tomoki; Yamasaki, Makoto; Mori, Masaki; Yuichiro Doki, And
2017-12-01
The skills necessary for performing effective laparoscopic suturing are difficult to acquire; as a result, simulators for learning these skills are rapidly becoming integrated into surgical training. The aim of the study was to verify whether a new hybrid simulator has the potential to measure skill improvement in young, less experienced gastroenterological surgeons. The study included 12 surgeons (median age, 29 (27-38)] years; 11 men (91.7%), one woman (8.3%)) who participated in a two-day laparoscopic training seminar. We used the new simulator before and after the program to evaluate individual performance. Skills were evaluated using five criteria: volume of air pressure leakage, number of full-thickness sutures, suture tension, wound area, and performance time. Air pressure leakage was significantly higher after than before the training (p = .027). The number of full-thickness sutures was significantly higher post-training (p < .01). Suture tension was significantly less post-training (p = .011). Wound opening areas were significantly smaller post-training (p = .018). Performance time was significantly shorter post-training (p = .032). Our study demonstrated the assessment quality of this new laparoscopic suture simulator.
Takazawa, Shinya; Ishimaru, Tetsuya; Fujii, Masahiro; Harada, Kanako; Sugita, Naohiko; Mitsuishi, Mamoru; Iwanaka, Tadashi
2013-11-01
We have developed a thin needle driver with multiple degrees-of-freedom (DOFs) for neonatal laparoscopic surgery. The tip of this needle driver has three DOFs for grasp, deflection and rotation. Our aim was to evaluate the performance of the multi-DOF needle driver in vertical plane suturing. Six pediatric surgeons performed four directional suturing tasks in the vertical plane using the multi-DOF needle driver and a conventional one. Assessed parameters were the accuracy of insertion and exit, the depth of suture, the inclination angle of the needle and the force applied on the model. In left and right direction sutures, the inclination angle of the needle with the multi-DOF needle driver was significantly smaller than that with the conventional one (p = 0.014, 0.042, respectively). In left and right direction sutures, the force for pulling the model with the multi-DOF needle driver was smaller than that with the conventional one (p = 0.036, 0.010, respectively). This study showed that multi-directional suturing on a vertical plane using the multi-DOF needle driver had better needle trajectories and was less invasive as compared to a conventional needle driver.
Cha, Dong Min; Kim, Kyeong Hwan; Choi, Hyuk Jin; Wee, Won Ryang
2012-01-01
Purpose To compare the effect of using fibrin glue or 10-0 nylon sutures on the clinical outcome of patients undergoing pterygium excision and conjunctival autografting. Methods We retrospectively reviewed the medical records of 52 eyes from 46 patients who underwent pterygium excision and conjunctival autografting and were followed up for more than 3 months. The operation duration, postoperative inflammation, complications, and recurrence rates were compared between groups of 20 patients (22 eyes) for whom fibrin glue was used (fibrin glue group) and 26 patients (30 eyes) for whom suturing was performed with 10-0 nylon (suture group) in pterygium excision and conjunctival autografting. Results The operation duration was 27.71 (5.22) minutes in the fibrin glue group and 43.30 (8.18) minutes in the suture group (p = 0.000). Seven days after the operation, the fibrin glue group showed milder conjunctival inflammation than the suture group (p = 0.000). Postoperative complications and corneal recurrence rates were not statistically different between the two groups. Conclusions The use of fibrin glue in pterygium excision with conjunctival autografting is likely to be a more effective, safer procedure than suturing. PMID:23204794
Cold Plasma Welding System for Surgical Skin Closure: In Vivo Porcine Feasibility Assessment.
Harats, Moti; Lam, Amnon; Maller, Michael; Kornhaber, Rachel; Haik, Josef
2016-09-29
Cold plasma skin welding is a novel technology that bonds skin edges through soldering without the use of synthetic materials or conventional wound approximation methods such as sutures, staples, or skin adhesives. The cold plasma welding system uses a biological solder applied to the edges of a skin incision, followed by the application of cold plasma energy. The objectives of this study were to assess the feasibility of a cold plasma welding system in approximating and fixating skin incisions compared with conventional methods and to evaluate and define optimal plasma welding parameters and histopathological tissue response in a porcine model. The cold plasma welding system (BioWeld1 System, IonMed Ltd, Yokneam, Israel) was used on porcine skin incisions using variable energy parameters. Wound healing was compared macroscopically and histologically to incisions approximated with sutures. When compared to sutured skin closure, cold plasma welding in specific system parameters demonstrated comparable and favorable wound healing results histopathologically as well as macroscopically. No evidence of epidermal damage, thermal or otherwise, was encountered in the specified parameters. Notably, bleeding, infection, and wound dehiscence were not detected at incision sites. Skin incisions welded at extreme energy parameters presented second-degree burns. Implementation of cold plasma welding has been shown to be feasible for skin closure. Initial in vivo results suggest cold plasma welding might provide equal, if not better, healing results than traditional methods of closure.
21 CFR 878.5000 - Nonabsorbable poly(ethylene terephthalate) surgical suture.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Nonabsorbable poly(ethylene terephthalate... Devices § 878.5000 Nonabsorbable poly(ethylene terephthalate) surgical suture. (a) Identification. Nonabsorbable poly(ethylene terephthalate) surgical suture is a multifilament, nonabsorbable, sterile, flexible...
Taube, M.; Porter, R. J.; Lord, P. H.
1983-01-01
We have conducted a controlled trial to compare skin closure using conventional interrupted sutures with a combination of subcuticular suture and sterile Micropore tape in 169 patients undergoing appendicectomy, inguinal herniorrhaphy, or saphenofemoral ligation. We have found that the combination technique consistently gives a better cosmetic result and that the tape acts well as a dressing, is convenient, and is well tolerated by patients. Images Fig. 1 Fig. 2 Fig. 3 Fig. 4 PMID:6344732
Wright, Andrew; Chang, Andrew; Bedi, Aarti Oza; Wamsteker, Erik-Jan; Elta, Grace; Kwon, Richard S; Carrott, Phillip; Elmunzer, B Joseph; Law, Ryan
2017-09-01
Esophageal fully covered self-expandable metal stents (FCSEMS) are indicated for the management of benign and malignant conditions of the esophagus including perforations, leaks, and strictures. FCSEMS are resistant to tissue ingrowth and are removable; however, stent migration occurs in 30-55% of cases. Endoscopic suture fixation of FCSEMS has been utilized to decrease the risk of stent migration though data supporting this practice remain limited. The primary aim of this study was to compare clinical outcomes and migration rate of patients who underwent placement of esophageal FCSEMS with and without endoscopic suture fixation. Our single-center, retrospective, cohort study includes patients who underwent esophageal FCSEMS placement with and without endoscopic suture fixation between January 1, 2012, and November 11, 2015. Baseline patient characteristics, procedural details, and clinical outcomes were abstracted. Logistic regression was performed to identify clinical and technical factors associated with outcomes and stent migration. A total of 51 patients underwent 62 FCSEMS placements, including 21 procedures with endoscopic suture fixation and 41 without. Suture fixation was associated with reduced risk of stent migration (OR 0.13, 95% CI 0.03-0.47). Prior stent migration was associated with significantly higher risk of subsequent migration (OR 6.4, 95% CI 1.6-26.0). Stent migration was associated with lower likelihood of clinical success (OR 0.21, 95% CI 0.06-0.69). There was a trend toward higher clinical success among patients undergoing suture fixation (85.7 vs. 60.9%, p = 0.07). Endoscopic suture fixation of FCSEMS was associated with a reduced stent migration rate. Appropriate patient selection for suture fixation of FCSEMS may lead to reduced migration in high-risk patients.
Complications in posteromedial arthroscopic suture of the medial meniscus.
Jan, N; Sonnery-Cottet, B; Fayard, J-M; Kajetanek, C; Thaunat, M
2016-12-01
All-inside posteromedial suture for lesions of the posterior horn of the medial meniscus in anterior cruciate ligament (ACL) repair provides effective freshening and good healing. The posteromedial portal provides satisfactory healing rates without increasing morbidity or complications rates. Intra- and postoperative complications were collected for a consecutive single-center series of 132 patients undergoing posteromedial hook suture of the medial meniscus in ACL repair. Meniscal healing was assessed as the rate of recurrence of symptomatic medial meniscus lesions (Barret criteria) and on revision surgery, if any, in terms of the aspect and extent of the iterative lesion. The severity of any sensory disorder was assessed by questionnaire. The intraoperative complications rate was 1.5% (2 saphenous vein punctures). At a mean 31months (range, 28-35months), there was no loss to follow-up. Twelve patients (9%) showed symptomatic recurrence of the medial meniscus lesion, requiring 10 repeat surgeries. In 6 cases (4.5%), the iterative lesion involved a smaller, more central part of the meniscus anterior to the sutures, of "postage-stamp" effect, possibly implicating the suture hook and/or non-absorbable sutures. There were no cases of infection or fistula. Postoperative hematoma occurred in 7% of patients. In total, 1.8% reported dysesthesia areas equal to or greater than the size of a credit card (45cm 2 ). Some retears, or "partial failures", may implicate a new lesion caused by the suture hook and possibly prolonged by non-resorbable sutures. Hematoma and sensory disorder rates were comparable to those reported in isolated ACL repair without posteromedial portal. The present results show that posteromedial arthroscopic hook suture in posterior medial meniscus tear provides good healing rates without increased morbidity due to the supplementary portal. IV. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
Massoud, Walid; Thanigasalam, Ruban; El Hajj, Albert; Girard, Frederic; Théveniaud, Pierre Etienne; Chatellier, Gilles; Baumert, Hervé
2013-07-01
To evaluate the use of a single needle driver with the V-Loc (Covidien, Dublin, Ireland) running suture and compare this with the use of 2 needle drivers with polyglactin interrupted sutures (IS) in dividing the dorsal venous complex (DVC) and forming the urethrovesical anastomosis (UVA) during robot-assisted radical prostatectomy (RARP). A prospective cohort study was performed to compare V-Loc (n = 40) with polyglactin (n = 40) sutures. Division of the dorsal venous complex and formation of the UVA during robot-assisted radical prostatectomy using V-Loc or polyglactin sutures were studied. Preoperative, intraoperative, and postoperative parameters were measured. V-Loc sutures were associated with a statistically significant reduction in mean dorsal vein suture time (3.15 minutes V-Loc vs 3.75 minutes IS, P = .02) and UVA anastomosis time (8.5 minutes V-Loc vs 11.5 minutes IS, P = .001). No significant difference was noted between operative time (121 minutes V-Loc vs 130 minutes IS, P = .199), delayed healing rates (5% V-Loc vs 7.5% IS, P = .238), continence rate at 12 months (97.5% V-Loc vs 95% IS, P = .368), and urethral stenosis rates (2.5% V-Loc vs 2.5% IS, P = .347) in both groups. The use of a V-Loc running suture with a single needle driver is a feasible, reproducible, and economic technique with no significant difference in continence rates and urethral stenosis rates, compared with the use of a traditional interrupted suture. Copyright © 2013 Elsevier Inc. All rights reserved.
Hanna, Amgad; Thompson, Daniel L; Hellenbrand, Daniel J; Lee, Jae-Sung; Madura, Casey J; Wesley, Meredith G; Dillon, Natalie J; Sharma, Tapan; Enright, Connor J; Murphy, William L
2016-07-01
Because of the dynamics of spinal cord injury (SCI), the optimal treatment will almost certainly be a combination approach to control the environment and promote axonal growth. This study uses peripheral nerve grafts (PNGs) as scaffolds for axonal growth while delivering neurotrophin-3 (NT-3) via calcium phosphate (CaP) coatings on surgical sutures. CaP coating was grown on sutures, and NT-3 binding and release were characterized in vitro. Then, the NT-3-loaded sutures were tested in a complete SCI model. Rats were analyzed for functional improvement and axonal growth into the grafts. The CaP-coated sutures exhibited a burst release of NT-3, followed by a sustained release for at least 20 days. Functionally, the rats with PNGs + NT-3-loaded sutures and the rats treated with PNGs scored significantly higher than controls on day 56 postoperatively. However, functional scores in rats treated with PNGs + NT-3-loaded suture were not significantly different from those of rats treated with PNGs alone. Cholera toxin subunit B (CTB) labeling rostral to the graft was not observed in any controls, but CTB labeling rostral to the graft was observed in almost all rats that had had a PNG. Neurofilament labeling on transverse sections of the graft revealed that the rats treated with the NT-3-loaded sutures had significantly more axons per graft than rats treated with an NT-3 injection and rats without NT-3. These data demonstrate that PNGs serve as scaffolds for axonal growth after SCI and that CaP-coated sutures can efficiently release NT-3 to increase axonal regeneration. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
Li, Guang-Tai; Li, Xiao-Fan; Wu, Baoping; Li, Guangrui
2016-04-01
To assess the efficacy and safety of longitudinal parallel compression suture to control heavy postpartum hemorrhage (PPH) in patients with placenta previa/accreta. Fifteen women received a longitudinal parallel compression suture to stop life-threatening PPH due to placenta previa with or without accreta during cesarean section. The suture apposed the anterior and posterior walls of the lower uterine segment together using an absorbable thread A 70-mm round needle with a Number-1 absorbable thread was used. The point of needle entry was 1 cm above the upper margin of the cervix and 1 cm from the right lateral border of the lower segment of the anterior wall. The suture was threaded through the uterine cavity to the serosa of the posterior wall. Then, it was directed upward and threaded from the posterior to the anterior wall at ∼1-2 cm above the upper boundary of the lower uterine segment and 3-cm medial to the right margin of the uterus. Both ends of the suture were tied on the anterior aspect of uterus. The left side was sutured in the same way. The success rate of the procedure was 86.7% (13/15). Two of 15 cases were concurrently administered gauze packing and achieved satisfactory hemostasis. All patients resumed a normal menstrual flow, and no postoperative anatomical or physiological abnormalities related to the suture were observed. Three women achieved further pregnancies after the procedure. Longitudinal parallel compression suture is a safe, easy, effective, practical, and conservative surgical technique to stop intractable PPH from the lower uterine segment, particularly in women who have a cesarean scar and placenta previa/accreta. Copyright © 2016. Published by Elsevier B.V.
Editorial Commentary: All-Suture Anchors, Foam Blocks, and Biomechanical Testing.
Brand, Jefferson C
2017-06-01
Barber's biomechanical work is well known to Arthroscopy's readers as thorough, comprehensive, and inclusive of new designs as they become available. In "All-Suture Anchors: Biomechanical Analysis of Pullout Strength, Displacement, and Failure Mode," the latest iteration, Barber and Herbert test all-suture anchors in both porcine femurs and biphasic foam. While we await in vivo clinical trials that compare all-suture anchors to currently used anchors, Barber and Herbert have provided data to inform anchor choice, and using their biomechanical data at time zero from all-suture anchor trials in an animal model, we can determine the anchors' feasibility for human clinical investigations. Copyright © 2017 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Medial Meniscus Posterior Root Repair Using a Transtibial Technique.
Woodmass, Jarret M; Mohan, Rohith; Stuart, Michael J; Krych, Aaron J
2017-06-01
The meniscal roots are critical in maintaining the normal shock absorbing function of the meniscus. If a meniscal root tear is left untreated, meniscal extrusion can occur rendering the meniscus nonfunctional resulting in degenerative arthritis. Two main repair techniques are described: (1) suture anchors (direct fixation) and (2) sutures pulled through a tibial tunnel (indirect fixation). Meniscal root repair using a suture anchor technique is technically challenging requiring a posterior portal and a curved suture passing device that can be difficult to manipulate within the knee. We present a technique for posterior medial meniscus root repair using 3 sutures (1 leader, 2 cinch), standard arthroscopy portals, and transtibial fixation. Overall, this technique simplifies a challenging procedure and allows for familiarity and efficiency.
Kudva, Adarsh; Kamath, Abhay; Cariappa, K M; Gadicherla, Srikanth; Dhara, B Vasantha
2017-12-01
An ectropion is a complication that can arise from reconstruction in the infraorbital region. Often, this complication occurs despite proper positioning of the lower lid at the time of closure. Various transcutaneous approaches to orbit skeleton have investigated in view of complication arising from them. A subtarsal approach with a postoperative Frost suture gives an advantage to reduce the occurrence of ectropion especially after treatment of orbital floor fractures. This case describes a method of subcuticular suturing technique for subtarsal incision of lower lid which can be used to support the lid during healing period, thus decreasing the rate of ectropion. The technique described here is an alterative method for frost suturing with certain advantages.
Bronchopulmonary levage to remove pulmonary casts and plugs.
Passy, V; Ermshar, C
1976-04-01
Therapy for such obstructive pulmonary lung diseases as alveolar proteinosis, pneumonia, asthma, bronchiectasis, and cystic fibrosis, ranges from medical therapy to inhalation therapy to direct bronchoscopy and irrigation. The basic pathophysiologic feature is the retention of mucous secretions and foreign material within the lungs and therapy directed to removal of these secretions. Bronchopulmonary lavage recently has been suggested as an effective tool toward resolution of these illnesses. The otolaryngologist, who is adept in endoscopy, is asked to perform bronchoscopic procedures with washings to aid in the alleviation of these obstructive pulmonary diseases. This paper deals with the effectiveness of massive bronchopulmonary lavage in the elimination of severe chronic obstructive pulmonary lung diseases.
[Rehabilitation after anterior cruciate ligament suturing].
Andrtová, M; Chlupatá, I
1994-01-01
The authors discuss problems of rehabilitation after suture of the anterior cruciate ligament where frequently errors are committed and where inadequate rehabilitation may cause damage to the patient. Different periods of rehabilitation after LCA sutures are discussed and suitable methods of exercise for different periods are recommended.
Muresan, Claude; Lee, Tommy H; Seagull, Jacob; Park, Adrian E
2010-10-01
To help optimize the use of limited resources in trainee education, we developed a prospective randomized trial to determine the most effective means of teaching laparoscopic suturing to novices. Forty-one medical students received rudimentary instruction in intracorporeal suturing, then were pretested on a pig enterotomy model. They then were posttested after completion of 1 of 4 training arms: laparoscopic suturing, laparoscopic drills, open suturing, and virtual reality (VR) drills. Tests were scored for speed, accuracy, knot quality, and mental workload (National Aeronautics and Space Administration [NASA] Task Load Index). Paired t tests were used. Task time was improved in all groups except the VR group. Knot quality improved only in the open or laparoscopic suturing groups. Mental workload improved only for those practicing on a physical laparoscopic trainer. For novice trainees, the efficacy of VR training is questionable. In contrast, the other training methods had benefits in terms of time, quality, and perceived workload. Copyright © 2010 Elsevier Inc. All rights reserved.
Assessment of Intracorporeal Suturing in Single-Port Surgery Using an Experimental Suturing Model.
Ishiyama, Yasuhiro; Inaki, Noriyuki; Bando, Hiroyuki; Yamada, Tetsuji
2017-04-01
The aim of this study is to assess the difficulty of intracorporeal suturing in single-port surgery, using experimental suturing model in dry box. Subjects were divided for three groups: seven experienced laparoscopic surgeons, seven surgical residents, and seven interns. An experimental suturing model is developed, and working angle was set from 0° to 90°. The completion rate in 0° was significantly lower than that in the other angles. Completion rate of group A was higher than that of the other groups. Precision of task in group A was significantly higher than that of group B and group C in 0° and 60°. Stress score in 0° were significantly higher than that in the other angles. Our study demonstrated that intracorporeal suturing in single-port surgery seems to be more difficult than conventional laparoscopic surgery. Our data should be taken the institution under consideration for introduction of single-port surgery.
Ozaki, Mine; Takushima, Akihiko; Momosawa, Akira; Kurita, Masakazu; Harii, Kiyonori
2008-07-01
For a treatment of facial paralysis, suture suspension of soft tissue is considered effective due to its less invasiveness and relatively simple technique, with minimal bruising and rapid recovery. However, suture suspension effect may not last for a long period of time. We obtained good outcome with temporary static suture suspension in 5 cases of severe facial paralysis in the intervening period between the onset of paralysis and expected spontaneous recovery. We used the S-S Cable Suture (Medical U&A, Tokyo, Japan), which was based on the modification of previously established method using the Gore-Tex cable suture originally reported by Sasaki et al in 2002. Because of the ease of technique and relatively strong lifting capability of the malar pad, we recommend it as a useful procedure for a patient suffering acute facial paralysis with possible spontaneous recovery for an improved quality of life by the quick elimination of facial distortion.
Coexistence of Wormian Bones With Metopism, and Vice Versa, in Adult Skulls.
Cirpan, Sibel; Aksu, Funda; Mas, Nuket; Magden, Abdurrahman Orhan
2016-03-01
The aim of the study is to investigate coexistence of Wormian bones with metopism, and vice versa, in adult skulls. A total of 160 dry adult human skulls of unknown sex and ages were randomly selected from the Gross Anatomy Laboratory of Medical School of Dokuz Eylul University. The skulls were examined for presence of metopism, Wormian bones (WB), and coexistence of WBs with metopism and vice versa. Topographic distribution of the WBs was macroscopically evaluated within the skulls including metopism. The photographs were being taken with Canon 400B (55 mm objective). The frequency of metopism and WBs in 160 skulls is 7.50% (12/160) and 59.3% (95/160), respectively, P < 0.05 (). The incidence of coexistence of WBs with metopism was found as 11 of 12 skulls (91.66%), whereas the incidence of coexistence of metopism with WBs was found as 11 of 95 skulls (11.58%), P < 0.05 (). There were totally 23 sutures including WBs in 11 skulls, which had metopism (). The number (%) of metopic skulls for each specific suture including WBs were found as: 11 lamdoid sutures in 7/11 (63.63%) skulls, 4 lambda in 4/11 (36.36%) skulls, 2 asterion in 2/11 (18.18%) skulls, 1 squamous in 1/11 (9.09%) skull, 2 sagittal in 2/11 (18.18%) skulls, and 3 parieromsatoid sutures in 2/11 (18.18%) skulls (). The distribution of these 23 WBs in sutures of 11 skulls including metopisms is determined as follows: 11/23 (47.82%) WBs at lambdoid sutures [5/23 (21.74%) at the right lambdoid sutures and 6/23 (26.08%) at the left lambdoid sutures, and 4 pair of 11 WBs bilaterally located]; 4 (17.39%) WBs at lambda; 2/23 (8.69%) WBs at asterion [1/23 (4.34%) at the right asterion and 1/23 (4.34%) at the left asterion of 2 diverse skulls]; 2/23 (8.69%) WBs at sagittal sutures; 1/23 (4.34%) WBs at the left squamous suture; 3/23 (13.04%) WBs at parietomastoid sutures [2/23 (8.69%) at the right parietomastoid sutures and 1/23 (4.34%) at the left parietomastoid suture and 1 pair of them bilaterally located; , ].(Figure is included in full-text article.)(Table is included in full-text article.)(Table is included in full-text article.) : There was a significant difference in rates between coexistence of WBs with metopism (11/12, 91.66%) and coexistence of metopism with WBs (11/95, 11.58%). The factors leading to metopism may also lead to WBs, whereas that the factors leading to WBs may not lead to metopism.
FGFR2c-mediated ERK-MAPK activity regulates coronal suture development
Pfaff, Miles J.; Xue, Ke; Li, Li; Horowitz, Mark C.; Steinbacher, Derek M.; Eswarakumar, Jacob V.P.
2017-01-01
Fibroblast growth factor receptor 2 (FGFR2) signaling is critical for proper craniofacial development. A gain-of-function mutation in the 2c splice variant of the receptor’s gene is associated with Crouzon syndrome, which is characterized by craniosynostosis, the premature fusion of one or more of the cranial vault sutures, leading to craniofacial maldevelopment. Insight into the molecular mechanism of craniosynostosis has identified the ERK-MAPK signaling cascade as a critical regulator of suture patency. The aim of this study is to investigate the role of FGFR2c-induced ERK-MAPK activation in the regulation of coronal suture development. Loss-of-function and gain-of-function Fgfr2c mutant mice have overlapping phenotypes, including coronal synostosis and craniofacial dysmorphia. In vivo analysis of coronal sutures in loss-of-function and gain-of-function models demonstrated fundamentally different pathogenesis underlying coronal suture synostosis. Calvarial osteoblasts from gain-of-function mice demonstrated enhanced osteoblastic function and maturation with concomitant increase in ERK-MAPK activation. In vitro inhibition with the ERK protein inhibitor U0126 mitigated ERK protein activation levels with a concomitant reduction in alkaline phosphatase activity. This study identifies FGFR2c-mediated ERK-MAPK signaling as a key mediator of craniofacial growth and coronal suture development. Furthermore, our results solve the apparent paradox between loss-of-function and gain-of-function FGFR2c mutants with respect to coronal suture synostosis. PMID:27034231
Aqua splint suture technique in isolated zygomatic arch fractures.
Kim, Dong-Kyu; Kim, Seung Kyun; Lee, Jun Ho; Park, Chan Hum
2014-04-01
Various methods have been used to treat zygomatic arch fractures, but no optimal modality exists for reducing these fractures and supporting the depressed bone fragments without causing esthetic problems and discomfort for life. We developed a novel aqua splint and suture technique for stabilizing isolated zygomatic arch fractures. The objective of this study is to evaluate the effect of novel aqua splint and suture technique in isolated zygomatic arch fractures. Patients with isolated zygomatic arch fractures were treated by a single surgeon in a single center from January 2000 through December 2012. Classic Gillies approach without external fixation was performed from January 2000 to December 2003, while the novel technique has been performed since 2004. 67 consecutive patients were included (Classic method, n = 32 and Novel method, n = 35). An informed consent was obtained from all patients. The novel aqua splint and suture technique was performed by the following fashion: first, we evaluated intraoperatively the bony alignment by ultrasonography and then, reduced the depressed fracture surgically using the Gillies approach. Thereafter, to stabilize the fracture and obtain the smooth facial figure, we made an aqua splint that fit the facial contour and placed monofilament nonabsorbable sutures around the fractured zygomatic arch. The novel aqua splint and suture technique showed significantly correlated with better cosmetic and functional results. In conclusion, the aqua splint suture technique is very simple, quick, safe, and effective for stabilizing repositioned zygomatic arch fractures. The aqua splint suture technique can be a good alternative procedure in isolated zygomatic arch fractures.
NASA Astrophysics Data System (ADS)
Le, Hanh N. D.; Opferman, Justin; Decker, Ryan; Cheon, Gyeong W.; Kim, Peter C. W.; Kang, Jin U.; Krieger, Axel
2016-04-01
Anastomosis, the connection of two structures, is a critical procedure for reconstructive surgery with over 1 million cases/year for visceral indication alone. However, complication rates such as strictures and leakage affect up to 19% of cases for colorectal anastomoses and up to 30% for visceral transplantation anastomoses. Local ischemia plays a critical role in anastomotic complications, making blood perfusion an important indicator for tissue health and predictor for healing following anastomosis. In this work, we apply a real time multispectral imaging technique to monitor impact on tissue perfusion due to varying interrupted suture spacing and suture tensions. Multispectral tissue images at 470, 540, 560, 580, 670 and 760 nm are analyzed in conjunction with an empirical model based on diffuse reflectance process to quantify the hemoglobin oxygen saturation within the suture site. The investigated tissues for anastomoses include porcine small (jejunum and ileum) and large (transverse colon) intestines. Two experiments using interrupted suturing with suture spacing of 1, 2, and 3 mm and tension levels from 0 N to 2.5 N are conducted. Tissue perfusion at 5, 10, 20 and 30 min after suturing are recorded and compared with the initial normal state. The result indicates the contrast between healthy and ischemic tissue areas and assists the determination of suturing spacing and tension. Therefore, the assessment of tissue perfusion will permit the development and intra-surgical monitoring of an optimal suture protocol during anastomosis with less complications and improved functional outcome.
Ohata, Erika; Matsuo, Kiyoshi; Ban, Ryokuya; Shiba, Masato; Yasunaga, Yoshichika
2013-01-01
Background: For surgical suturing, a Webster needle holder uses wrist supinating with supinator and extrinsic muscles, whereas a pen needle holder uses finger twisting with intrinsic and extrinsic muscles. Because the latter is better suited to microsurgery, which requires fine suturing with less forearm muscle movement, we have recently adopted an enlarged pen needle holder scaled from a micro needle holder for fine skin suturing. In this study, we assessed whether the enlarged pen needle holder reduced forearm muscle movement during fine skin suturing as compared with the Webster needle holder. Methods: A fine skin-suturing task was performed using pen holding with the enlarged micro needle holder or scissor holding with the Webster needle holder by 9 experienced and 6 inexperienced microsurgeons. The task lasted for 60 seconds and was randomly performed 3 times for each method. Forearm flexor and extensor muscular activities were evaluated by surface electromyography. Results: The enlarged pen needle holder method required significantly less forearm muscle movement for experienced microsurgeons despite it being their first time using the instrument. There was no significant difference between 2 methods for inexperienced microsurgeons. Conclusions: Experienced microsurgeons conserved forearm muscle movement by finger twisting in fine skin suturing with the enlarged pen needle holder. Inexperienced microsurgeons may benefit from the enlarged pen needle holder, even for fine skin suturing, to develop their internal acquisition model of the dynamics of finger twisting. PMID:23691259
Ohata, Erika; Matsuo, Kiyoshi; Ban, Ryokuya; Shiba, Masato; Yasunaga, Yoshichika
2013-01-01
For surgical suturing, a Webster needle holder uses wrist supinating with supinator and extrinsic muscles, whereas a pen needle holder uses finger twisting with intrinsic and extrinsic muscles. Because the latter is better suited to microsurgery, which requires fine suturing with less forearm muscle movement, we have recently adopted an enlarged pen needle holder scaled from a micro needle holder for fine skin suturing. In this study, we assessed whether the enlarged pen needle holder reduced forearm muscle movement during fine skin suturing as compared with the Webster needle holder. A fine skin-suturing task was performed using pen holding with the enlarged micro needle holder or scissor holding with the Webster needle holder by 9 experienced and 6 inexperienced microsurgeons. The task lasted for 60 seconds and was randomly performed 3 times for each method. Forearm flexor and extensor muscular activities were evaluated by surface electromyography. The enlarged pen needle holder method required significantly less forearm muscle movement for experienced microsurgeons despite it being their first time using the instrument. There was no significant difference between 2 methods for inexperienced microsurgeons. Experienced microsurgeons conserved forearm muscle movement by finger twisting in fine skin suturing with the enlarged pen needle holder. Inexperienced microsurgeons may benefit from the enlarged pen needle holder, even for fine skin suturing, to develop their internal acquisition model of the dynamics of finger twisting.
FGFR2c-mediated ERK-MAPK activity regulates coronal suture development.
Pfaff, Miles J; Xue, Ke; Li, Li; Horowitz, Mark C; Steinbacher, Derek M; Eswarakumar, Jacob V P
2016-07-15
Fibroblast growth factor receptor 2 (FGFR2) signaling is critical for proper craniofacial development. A gain-of-function mutation in the 2c splice variant of the receptor's gene is associated with Crouzon syndrome, which is characterized by craniosynostosis, the premature fusion of one or more of the cranial vault sutures, leading to craniofacial maldevelopment. Insight into the molecular mechanism of craniosynostosis has identified the ERK-MAPK signaling cascade as a critical regulator of suture patency. The aim of this study is to investigate the role of FGFR2c-induced ERK-MAPK activation in the regulation of coronal suture development. Loss-of-function and gain-of-function Fgfr2c mutant mice have overlapping phenotypes, including coronal synostosis and craniofacial dysmorphia. In vivo analysis of coronal sutures in loss-of-function and gain-of-function models demonstrated fundamentally different pathogenesis underlying coronal suture synostosis. Calvarial osteoblasts from gain-of-function mice demonstrated enhanced osteoblastic function and maturation with concomitant increase in ERK-MAPK activation. In vitro inhibition with the ERK protein inhibitor U0126 mitigated ERK protein activation levels with a concomitant reduction in alkaline phosphatase activity. This study identifies FGFR2c-mediated ERK-MAPK signaling as a key mediator of craniofacial growth and coronal suture development. Furthermore, our results solve the apparent paradox between loss-of-function and gain-of-function FGFR2c mutants with respect to coronal suture synostosis. Copyright © 2016 Elsevier Inc. All rights reserved.
Comparison of Fibrin Glue and Sutures for Conjunctival Wound Closure in Strabismus Surgery
Lee, Jae Hyung
2011-01-01
Purpose To evaluate and compare the efficacy and tolerance of fibrin glue and sutures for closing conjunctival wounds in strabismus surgery. Methods In a prospective trial, we performed strabismus surgery using limbal incisions. Conjunctival wounds were closed with fibrin glue in 20 eyes of 20 patients (fibrin group) and 8-0 polyglactin suture in 20 eyes of 20 patients (suture group). Postoperative pain, tearing, and inflammation were compared at 1 day, 1 week, 3 weeks, and 6 weeks after surgery. Conjunctival incision healing was also investigated. Results One day and one week post-operatively, pain and tearing scores were lower in the fibrin group (p = 0.000, respectively). Mean surgery time was significantly shorter in the fibrin (48 ± 5 minutes) than the suture group (63 ± 7 minutes) (p = 0.000). Inflammation was significantly more severe in the suture group until 3 weeks postoperative (p = 0.000, respectively), but conjunctival healing did not differ between the groups. Hyperemia appeared more prominent in the fibrin group 3 and 6 weeks after surgery (p = 0.087 and 0.000, respectively). Two eyes in the fibrin group showed conjunctival gaps of more than 2 mm, which closed spontaneously by three weeks after surgery. No allergic reactions or infections developed. Conclusions Fibrin glue proved to be as effective as sutures in closing conjunctival wounds. It provides more comfortable early postoperative courses and might be considered as an alternative to sutures in strabismus surgery. PMID:21655043
21 CFR 882.4650 - Neurosurgical suture needle.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Neurosurgical suture needle. 882.4650 Section 882.4650 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4650 Neurosurgical suture needle...
21 CFR 882.4650 - Neurosurgical suture needle.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Neurosurgical suture needle. 882.4650 Section 882.4650 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4650 Neurosurgical suture needle...
Arterially Delivered Mesenchymal Stem Cells Prevent Obstruction-Induced Renal Fibrosis
Asanuma, Hiroshi; Vanderbrink, Brian A.; Campbell, Matthew T.; Hile, Karen L.; Zhang, Hongji; Meldrum, Daniel R.; Meldrum, Kirstan K.
2010-01-01
Purpose Mesenchymal stem cells (MSCs) hold promise for the treatment of renal disease. While MSCs have been shown to accelerate recovery and prevent acute renal failure in multiple disease models, the effect of MSC therapy on chronic obstruction-induced renal fibrosis has not previously been evaluated. Materials and Methods Male Sprague-Dawley rats underwent renal artery injection of vehicle or fluorescent-labeled human bone marrow-derived MSCs immediately prior to sham operation or induction of left ureteral obstruction (UUO). One or 4 weeks later, the kidneys were harvested and the renal cortex analyzed for evidence of stem cell infiltration, epithelial-mesenchymal transition (EMT) as evidenced by E-cadherin/α-smooth muscle actin (α-SMA) expression and fibroblast specific protein (FSP+) staining, renal fibrosis (collagen content, Masson’s trichrome staining), and cytokine and growth factor activity (ELISA and real time RT-PCR). Results Fluorescent-labeled MSCs were detected in the interstitium of the kidney up to 4 weeks post-obstruction. Arterially delivered MSCs significantly reduced obstruction-induced α-SMA expression, FSP+ cell accumulation, total collagen content, and tubulointerstitial fibrosis, while simultaneously preserving E-cadherin expression, suggesting that MSCs prevent obstruction-induced EMT and renal fibrosis. Exogenous MSCs reduced obstruction-induced tumor necrosis factor-α (TNF-α) levels, but did not alter transforming growth factor-β1 (TGF-β1), vascular endothelial growth factor (VEGF), interleukin-10 (IL-10), fibroblast growth factor (FGF), or hepatocyte growth factor (HGF) expression. Conclusions Human bone marrow-derived MSCs remain viable several weeks after delivery into the kidney and provide protection against obstruction-induced EMT and chronic renal fibrosis. While the mechanism of MSCs-induced renal protection during obstruction remains unclear, our results demonstrate that alterations in TNF-α production may be involved. PMID:20850784
Sánchez-Margallo, F. M.; Latorre, R.; López-Albors, O.; Wise, R.; Malbrain, M. L. N. G.; Castellanos, G.
2016-01-01
Introduction Mechanical intestinal obstruction is a disorder associated with intra-abdominal hypertension and abdominal compartment syndrome. As the large intestine intraluminal and intra-abdominal pressures are increased, so the patient’s risk for intestinal ischaemia. Previous studies have focused on hypoperfusion and bacterial translocation without considering the concomitant effect of intra-abdominal hypertension. The objective of this study was to design and evaluate a mechanical intestinal obstruction model in pigs similar to the human pathophysiology. Materials and Methods Fifteen pigs were divided into three groups: a control group (n = 5) and two groups of 5 pigs with intra-abdominal hypertension induced by mechanical intestinal obstruction. The intra-abdominal pressures of 20 mmHg were maintained for 2 and 5 hours respectively. Hemodynamic, respiratory and gastric intramucosal pH values, as well as blood tests were recorded every 30 min. Results Significant differences between the control and mechanical intestinal obstruction groups were noted. The mean arterial pressure, cardiac index, dynamic pulmonary compliance and abdominal perfusion pressure decreased. The systemic vascular resistance index, central venous pressure, pulse pressure variation, airway resistance and lactate increased within 2 hours from starting intra-abdominal hypertension (p<0.05). In addition, we observed increased values for the peak and plateau airway pressures, and low values of gastric intramucosal pH in the mechanical intestinal obstruction groups that were significant after 3 hours. Conclusion The mechanical intestinal obstruction model appears to adequately simulate the pathophysiology of intestinal obstruction that occurs in humans. Monitoring abdominal perfusion pressure, dynamic pulmonary compliance, gastric intramucosal pH and lactate values may provide insight in predicting the effects on endorgan function in patients with mechanical intestinal obstruction. PMID:26849559
Degradation Characterization of Aliphatic POLYESTERS—IN Vitro Study
NASA Astrophysics Data System (ADS)
Vieira, A. C.; Vieira, J. C.; Guedes, R. M.; Marques, A. T.
2008-08-01
The most popular and important biodegradable polymers are aliphatic polyesters, such as polylactic acid (PLA), polyglycolic acid (PGA), polycaprolactone (PCL), polyhydoxyalkanoates (PHA's) and polyethylene oxide (PEO). However, each of these has some shortcomings which restrict its applications. Blending techniques are an extremely promising approach which can improve or tune the original properties of the polymers[1]. Aliphatic polyesters are a central class of biodegradable polymers, because hydrolytic and/or enzymatic chain cleavage of these materials leads to α-hydroxyacids, which in most cases are ultimately metabolized in human body. This is particularly useful for controlled release devices and for other biomedical applications like suture fibers and ligaments. For aliphatic polyesters, hydrolysis rates are affected by the temperature, molecular structure, and ester group density as well as by the species of enzyme used. The degree of crystallinity may be a crucial factor, since enzymes attack mainly the amorphous domains of a polymer. Four different aliphatic polyesters were characterized in terms of degradation. Sutures fibers of PGA-PCL, PGA, PLA-PCL and PDO were used in this study. Weight loss, pH, molecular weight, crystallinity and strength were measured after six stages of incubation in distilled water, physiological saline and phosphate buffer solution (PBS). Degradation rate was determined, using a first order kinetic equation for all materials in the three incubation media. A relatively wide range of mechanical properties and degradation rates were observed among the materials studied. PBS was the most aggressive environment for the majority of cases.
Assessing Impacts of Navigation Dredging on Atlantic Sturgeon (Acipenser oxyrinchus)
2014-11-01
fishes and insect larvae (Smith 1985, Dadswell 2006). Shallow water shoals located adjacent to both sides of the Federal navigation channel, provide a...incision was closed using sterile resorbitive suture material with four to five simple interrupted stitches. An iodine disinfectant was applied to the...1976). Assessment of techniques used to quantify salmon smolt entrainment by a hydraulic suction hopper dredge in the Fraser River estuary. Environment
Could the novel ‘double-hole’ technique be an alternative for the inflow occlusion method?
Bozok, Sahin; Gokhan, Ilhan; Izmir,, Kazdal; Berkan, Ozpak; Ismail, Yurekli; Mert, Kestelli; Serdar, Bayrak
2016-01-01
Summary Background Inflow occlusion on beating heart and cardiopulmonary bypass techniques have been proposed for the removal of foreign material, such as stents, catheters and mass lesions, from cardiac chambers. However, both techniques are not devoid of disadvantages and complications. In this article, we define an alternative, novel ‘double-hole’ technique, which is based on opening the right atrium without cardiopulmonary bypass . Methods Bovine hearts were obtained from a local supermarket. Two purse-string sutures were placed in the right atrium using 2-0 braided, non-absorbable polyester suture material, one close to the auricle, and the other close to the interatrial septum. The guidewire of a haemodialysis catheter was inserted through the superior vena cava into the right atrium and passed all the way through the right ventricle. Results We suggest that the double-hole technique may be useful, especially in revision cases with adhesions. Further research should be performed to document the efficacy and safety of this method. Conclusion We are aware that further extensive research is necessary to investigate the utility of this novel technique in contemporary cardiovascular surgery. We believe the doublehole technique has the potential to become a safe, practical and effective measure in the future. PMID:27078129
21 CFR 878.4495 - Stainless steel suture.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Stainless steel suture. 878.4495 Section 878.4495 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... Controls Guidance Document: Surgical Sutures; Guidance for Industry and FDA.” See § 878.1(e) for the...
21 CFR 878.4495 - Stainless steel suture.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Stainless steel suture. 878.4495 Section 878.4495 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4495 Stainless steel suture. (a...
21 CFR 878.4930 - Suture retention device.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Suture retention device. 878.4930 Section 878.4930 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4930 Suture retention device...
21 CFR 878.4495 - Stainless steel suture.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Stainless steel suture. 878.4495 Section 878.4495 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4495 Stainless steel suture. (a...
21 CFR 878.4495 - Stainless steel suture.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Stainless steel suture. 878.4495 Section 878.4495 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4495 Stainless steel suture. (a...
21 CFR 878.4930 - Suture retention device.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Suture retention device. 878.4930 Section 878.4930 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4930 Suture retention device...
21 CFR 878.4930 - Suture retention device.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Suture retention device. 878.4930 Section 878.4930 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4930 Suture retention device...
21 CFR 878.4495 - Stainless steel suture.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Stainless steel suture. 878.4495 Section 878.4495 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4495 Stainless steel suture. (a...
21 CFR 878.4930 - Suture retention device.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Suture retention device. 878.4930 Section 878.4930 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4930 Suture retention device...
21 CFR 878.4930 - Suture retention device.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Suture retention device. 878.4930 Section 878.4930 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4930 Suture retention device...
Fournié, A; Madzou, S; Sentilhes, L; Descamps, P
2008-12-01
Two cases of evisceration after caesarean sections performed according the Misgav Ladach General Hospital procedure (Stark's procedure) are reported. In these cases, omentum was sutured between the edges of fascia recti, creating a weakness of the abdominal sheath. These cases claim about a strict procedure for fascia suture. Also, these cases question about the parietal peritoneal closure and the drawing of rectus muscles, which are vertical breaks; so, these sutures close transversal incision of the abdominal wall with cross sutures, which are very secure.
Grover, Davinder S; Fellman, Ronald L
2016-06-01
To describe a novel technique for thermally marking the tip of a suture, in preparation for a gonioscopy-assisted transluminal trabeculotomy. One patient was used as an example for this technique. Technique report. The authors introduce a modification of a novel surgical procedure (GATT) in which a suture is marked and thermally blunted allowing a proper visualization while performing an ab interno, minimally invasive, circumferential 360-degree suture trabeculotomy. The authors have previously reported on the GATT surgery with the use of an illuminated microcatheter, which allowed for visualization of the tip of the catheter as it circumnavigated Schlemm canal. This modification allows for similar visualization of the tip of the suture, however, is much more cost-effective while still maintaining similar safety.
Lenz, Christopher G; Wieser, Karl; Lajtai, Georg; Meyer, Dominik C
2015-11-17
To compare instruments designed for arthroscopic suture handling during arthroscopic rotator cuff repair, to assess the force needed to penetrate the tendon, and to evaluate the residual defect size. Twenty-one instruments were each tested ten times on thawed sheep infraspinatus tendons. The force needed to pierce the tendon with each instrument was measured using a custom setup. Bone wax plates were used to make the perforation marks visible and to quantify the lesions each instrument created. The force to pierce a tendon had a range of 5.6-18.5 N/mm. Within the group of suture retrievers, the angled instruments required in average 85 % higher forces than straight instruments. The lesion area had a range of 2-7 mm(2). Suture retrievers produced significantly larger lesion sizes compared with suture shuttles. For the identical task of passing a suture through a tendon, differences exist regarding the ease of tendon penetration and potential damage to the tendon for different tools. The design, function, and resulting lesion size may be relevant and important for surgical handling and to avoid excess structural damage to the tendon. These results suggest that choosing the most appropriate tools for arthroscopic suture stitching influences the ease of handling and final integrity of the tissue.
Sarigul Guduk, Sukran; Karaca, Nezih
2018-04-01
Thread lifting is a minimally invasive procedure for lifting and repositioning tissues. Few articles with absorbable sutures exist in the literature. Furthermore there is no study focusing on complications of absorbable sutures. To describe complications of thread lifting using a totally absorbable suture composed of poly-L-lactic acid affixed with poly lactide/glycolide cones. Data regarding complications were analyzed retrospectively for 148 patients underwent thread lifting between June 2014 and February 2017. A total of 321 pairs of sutures used in the 148 patients studied. Overall 40 (27%) patients had complications regarded as minimal or moderate without permanent sequela. The most common complication was skin dimpling and irregularity (n = 17, 11.4%) followed by ecchymosis (n = 12, 8.1%), suture extrusion (n = 4, 2.7%), and pain (n = 4, 2.7%) Except one patient, dimpling, and irregularity resolved in all patients after 3-7 days spontaneously. Suture migration was observed in 2 (1.35%) patients. Hematoma and infection were seen in 2 patients one for each. The procedure using sutures made of absorbable poly-L-lactic acid and poly lactide/glycolide is a relatively safe procedure without major complications. © 2018 Wiley Periodicals, Inc.
Murashita, Takashi; Okada, Yukikatsu; Kanemitsu, Hideo; Fukunaga, Naoto; Konishi, Yasunobu; Nakamura, Ken; Koyama, Tadaaki
2014-01-01
We investigated the long-term outcomes of suture/ring tricuspid valve annuloplasty for functional tricuspid regurgitation associated with degenerative mitral regurgitation. We retrospectively reviewed patients who underwent flexible ring tricuspid valve annuloplasty (n = 120) or suture tricuspid valve annuloplasty (n = 42) for functional tricuspid regurgitation concomitant with surgery for degenerative mitral regurgitation (mean follow-up duration, 5.3 ± 5.1 years). The mean age of patients was 62.5 ± 13.1 years. Thirty-day mortality was zero in the suture group, and 0.8% in the ring group. Tricuspid regurgitation grade at discharge was lower in the ring group ( p = 0.002). No difference was observed between survival and freedom from major cardiac/cerebrovascular adverse events between the groups. However, freedom from ≥moderate tricuspid regurgitation was higher in the ring group (Log-rank p = 0.003). From univariate analysis, the risk factors for ≥moderate TR were suture annuloplasty and preoperative tricuspid regurgitation grade. No reoperation for recurrent tricuspid regurgitation occurred in either group because symptoms experienced by patients with recurrent tricuspid regurgitation were relatively insignificant. Concomitant tricuspid annuloplasty using flexible bands offered improved durability than suture annuloplasty for preventing postoperative tricuspid regurgitation progression.
Investigation of the best suture pattern to close a stuffed Christmas turkey.
Verwilghen, D; Busoni, V; van Galen, G; Wilke, M
Instructions on how to debone and stuff a turkey are available, but what is the best way to close it up? A randomised trial involving 15 turkeys was performed in order to evaluate skin disruption scores and cosmetic outcomes following the use of different suture patterns. Turkeys were deboned, stuffed and cooked according to guidelines of the US Department of Agriculture Food Safety and Inspection Services. After stuffing, they were randomly assigned to one of five closure groups: simple continuous Lembert; simple continuous Cushing; simple continuous Utrecht; simple continuous; or staples. Turkeys were cooked at 180 °C for two hours ensuring core temperature reached 75 °C. Suture line integrity was evaluated after removal of the sutures and the cosmetic aspect was graded. Before cooking, the Utrecht pattern and skin staples offered the best cosmetic result. After removal of the sutures, the skin remained intact only in the stapled group. All other suture patterns disrupted the skin after removal of the sutures, rendering the turkey less cosmetically appealing for serving. Closure of a stuffed turkey was best performed using skin staples to achieve the best cosmetic results. Using this technique you will be able to impress family and friends at a Christmas dinner, and finally show them your surgical skills.
Winkel, R; Kalbhenn, O; Hoffmann, R
2012-06-01
This retrospective examination compares the results of finger flexor tendon sutures with 2 strands and 4 strands. It was checked, whether and how 2 more strands influenced the rupture rate, the movement of the finger and the contentment of the patients. From 1996 to 2000 for the core suture of the flexor tendon of fingers we used 2 strands. 35 patients with 40 tendon sutures of 73 patients were examined. From 2001 to 2005 we used for the core suture 2 loop threads. 53 patients with 64 tendon sutures from a total of 111 patients were examined. At least 12 months had passed between operation and the examination. The rupture rate and the range of movement of each finger joint and the total mobility of the affected fingers were evaluated. Each case was compared to the uninjured opposite hand. The functional result was judged according to the score of Buck-Gramcko. The patient's contentment was recorded by the DASH (disability of arm, shoulder and hand) score. Effects of gender, age, accompanying injuries, zone of the injury and their influence on the results were analysed. The Buck-Gramcko score showed in the 2-strand group a distribution from summarised 70% "excellent" and "good" and 30% "fair" and "poor". In the 4-strand-group the relation was 93.7% "excellent" and "good", 6.3% "fair", one "poor". In the 2-strand group 2/40 (5%) of the tendon sutures ruptured, in the 4-strand group 1/64 (1.6%) ruptured. The average DASH value in the 2-strands-group was 16.6/100, in the 4-strands-group 18.1/100 when 0 is the best possible result and 100 the worst. The patient judgement in the 2-strand group was summarised to 70% for "excellent" and "good" and 30% "fair" and "poor". In the 4-strand group the patient's judgment was summarised in 75% "excellent" and "good" and in 25% "fair". The results of flexor tendon sutures with 4-strand core sutures have been superior to the results with 2-strand core suture according to range of motion of the fingers (P <0.005). © Georg Thieme Verlag KG Stuttgart · New York.
NASA Astrophysics Data System (ADS)
Robertson, Alastair H. F.; Collins, Alan S.
2002-02-01
The Shyok Suture Zone (Northern Suture) of North Pakistan is an important Cretaceous-Tertiary suture separating the Asian continent (Karakoram) from the Cretaceous Kohistan-Ladakh oceanic arc to the south. In previously published interpretations, the Shyok Suture Zone marks either the site of subduction of a wide Tethyan ocean, or represents an Early Cretaceous intra-continental marginal basin along the southern margin of Asia. To shed light on alternative hypotheses, a sedimentological, structural and igneous geochemical study was made of a well-exposed traverse in North Pakistan, in the Skardu area (Baltistan). To the south of the Shyok Suture Zone in this area is the Ladakh Arc and its Late Cretaceous, mainly volcanogenic, sedimentary cover (Burje-La Formation). The Shyok Suture Zone extends northwards (ca. 30 km) to the late Tertiary Main Karakoram Thrust that transported Asian, mainly high-grade metamorphic rocks southwards over the suture zone. The Shyok Suture Zone is dominated by four contrasting units separated by thrusts, as follows: (1). The lowermost, Askore amphibolite, is mainly amphibolite facies meta-basites and turbiditic meta-sediments interpreted as early marginal basin rift products, or trapped Tethyan oceanic crust, metamorphosed during later arc rifting. (2). The overlying Pakora Formation is a very thick (ca. 7 km in outcrop) succession of greenschist facies volcaniclastic sandstones, redeposited limestones and subordinate basaltic-andesitic extrusives and flow breccias of at least partly Early Cretaceous age. The Pakora Formation lacks terrigenous continental detritus and is interpreted as a proximal base-of-slope apron related to rifting of the oceanic Ladakh Arc; (3). The Tectonic Melange (<300 m thick) includes serpentinised ultramafic rocks, near mid-ocean ridge-type volcanics and recrystallised radiolarian cherts, interpreted as accreted oceanic crust. (4). The Bauma-Harel Group (structurally highest) is a thick succession (several km) of Ordovician and Carboniferous to Permian-Triassic, low-grade, mixed carbonate/siliciclastic sedimentary rocks that accumulated on the south-Asian continental margin. A structurally associated turbiditic slope/basinal succession records rifting of the Karakoram continent (part of Mega-Lhasa) from Gondwana. Red clastics of inferred fluvial origin ('molasse') unconformably overlie the Late Palaeozoic-Triassic succession and are also intersliced with other units in the suture zone. Reconnaissance further east (north of the Shyok River) indicates the presence of redeposited volcaniclastic sediments and thick acid tuffs, derived from nearby volcanic centres, presumed to lie within the Ladakh Arc. In addition, comparison with Lower Cretaceous clastic sediments (Maium Unit) within the Northern Suture Zone, west of the Nanga Parbat syntaxis (Hunza River) reveals notable differences, including the presence of terrigenous quartz-rich conglomerates, serpentinite debris-flow deposits and a contrasting structural history. The Shyok Suture Zone in the Skardu area is interpreted to preserve the remnants of a rifted oceanic back-arc basin and components of the Asian continental margin. In the west (Hunza River), a mixed volcanogenic and terrigenous succession (Maium Unit) is interpreted to record syn-deformational infilling of a remnant back-arc basin/foreland basin prior to suturing of the Kohistan Arc with Asia (75-90 Ma).
Evaluating the use of octyl-2-cyanoacrylate in unilateral cleft lip repair
Malhotra, Vijaylaxmy; Dayashankara Rao, J. K.; Arya, Varun; Sharma, Shalender; Singh, Sushil; Luthra, Payal
2016-01-01
Background: Facial cosmetic results are one of the most concerning issues for the parents who get their children operated for cleft lip. Moreover, the postoperative care of the surgical site, the discomfort associated with the suture removal, and additional visit for suture removal are other reasons which encourages one to use any new technologies that may replace the need for suture placement. In this study, we used octyl-2-cyanoacrylate, a tissue adhesive which offers a viable alternative to traditional techniques without compromising optimal wound closure. Objective: To perform a comprehensive comparison of the outcomes from the use of Dermabond in patients undergoing primary repair of congenital cleft lip ± palate anomalies. Materials and Methods: Twenty patients, in the age group of 3–18 months were treated surgically for unilateral cleft lip deformity using Millard rotation-advancement flap. Pre- and post-operative photographs of the patients were taken at 1 week, 2 week, 1 month, 6 months, and 1 year postoperatively and were evaluated using Vancouver scar scale which was given by Sullivan in 1990. Paired t-test was used for statistical analysis. Results: Increased vascularity (hyperemia) was seen in the 1st and 2nd week in 35% and 30% patients, respectively which gradually reduced to normal in subsequent follow-ups. The scar was flat in 85% of patients in 1st week, and the number decreased to 10% at the end of 1 year. No wound dehiscence was found in any patients. Statistical analysis showed that among all the follow-ups, only the difference between the first and second follow-ups. Comparison of the results of 1 week with all other follow-ups yielded no significant results. Conclusion: Octyl-2-cyanoacrylate can be used for cleft lip closure effectively. The procedure is relatively painless and quick. Added to this are benefits of protection from wound infection since the material is bacteriostatic. PMID:28356686
History of hypospadias: Lost in translation.
Hadidi, Ahmed T
2017-02-01
The evolution of hypospadias surgery can be classified under 3 periods that were closely related to advances in surgical instruments, introduction of anesthesia, and newer suture materials. Stretching dominated the early period, tunneling during the Middle Ages, and flaps during the modern period. Suture materials have included at various time silver wires, horsehair, and stainless steel. Examination and translation of the original manuscripts showed that Galen recommended stretching and suturing of glanular hypospadias and not amputation or partial penectomy as has been currently reported. The term chordee was first introduced in the 18th century in relation to gonorrhea and was defined as "painful imperfect erection of the penis during gonorrhea, with downward incurvation." This was a common complication of gonorrhea before the introduction of antibiotics. Mettauer, Duplay, Mayo, and others used the terms incurvation, ventral deformity, ventral curvature, and others. Clinton Smith in 1938 was the first surgeon to use the term congenital chordee in direct relation to hypospadias. The use of prepuce for urethroplasty, popular now, was first reported by Liston in 1838, Rochet in 1899, Russell in 1900, and Mayo in 1901. The two stage repair performed in the early 20th century differed from that in the early 21st century in that urethroplasty was performed in the first stage and only anastomosis to the original meatus was performed in the second stage. The two-stage repair, currently known as Bracka's two-stage repair, was first described in 1962 by Cloutier. The use of the urethral plate in epispadias was first described by Liston in 1838, Thiersch in 1869 and by Anger & Duplay in hypospadias in 1874. Partially epithelialized urethroplasty using the urethral plate was described by Duplay in 1880, Russell 1915, Denis Browne 1940, Reddy 1975, Orkiszewski 1987, Rich 1989, and Snodgrass in 1994. V. Copyright © 2017 Elsevier Inc. All rights reserved.
Lázaro-Carrasco, M T; Morales, P; Ferreiro, M J; Borro, J M; Varela, A; Vicente, R; Ramos, F; Estada, J A
1999-05-01
Retrospective analysis of cystic fibrosis patients who underwent pulmonary transplantation at Clínica Puerta de Hierro, Madrid, and at Hospital La Fe, Valencia. Since the beginning of the programme and until March 1998, a total of 63 patients with cystic fibrosis were studied. Among transplanted patients, 18 were males and 16 females, with a mean age of 18.9 years. All patients underwent sequential bilateral pulmonary transplantation. After transplantation, the most common complication was bacterial pneumonia which affected all patients. Six patients had dehiscence or stenosis of the bronchial suture. Other specific complications of this condition by frequency were intestinal obstruction and diabetes mellitus. Six patients developed obliterans bronchiolitis and one of them underwent a repeat transplantation. Three out of the 34 patients died, and the likelihood of survival after one and three years was 94%. Respiratory function tests and PaO2 peaked at sixth post-transplantation month. Pulmonary transplantation is a therapeutic option to be considered for the patient with cystic fibrosis and severe involvement of his/her pulmonary disease.
Robotic-assisted repair of iatrogenic ureteral ligation following robotic-assisted hysterectomy.
Kalisvaart, Jonathan F; Finley, David S; Ornstein, David K
2008-01-01
Ureteral injuries, while rare, do occur during gynecologic procedures. The expansion of laparoscopic and robotic pelvic surgical procedures increases the risk of ureteral injury from these procedures and suggests a role for minimally invasive approaches to the delayed repair of ureteral injuries. We present, to our knowledge, the first case of delayed robotic-assisted ureteral deligation and ureterolysis following iatrogenic ureteral injury occurring during a robotic abdominal hysterectomy. We present a case report and review of the literature. A 57-year-old female underwent a seemingly uncomplicated robotic-assisted laparoscopic total abdominal hysterectomy and bilateral oophorectomy for symptomatic fibroids. On postoperative day 8, she presented with persistent right flank pain. Imaging studies revealed high-grade ureteral obstruction consistent with suture ligation of the right ureter. She underwent successful robotic-assisted ureteral deligation and ureterolysis. Her postoperative course was unremarkable, and she was discharged home on postoperative day 1 from the deligation. Robotic-assisted management of complications from urologic or gynecologic surgery is technically feasible. This can potentially preserve the advantages to the patient that are being seen from the initial less-invasive surgery.
Ito, Kiyoshi; Aoyama, Tatsuro; Horiuchi, Tetsuyoshi; Hongo, Kazuhiro
2015-12-01
The nonpenetrating titanium clip has been successfully used in peripheral arterial bypass surgery. The purpose of this study was to evaluate the leakage pressures and patterns of nonpenetrating titanium clips using a simple model that mimicked spinal surgery. In addition, the authors describe their surgical experience with these clips and the follow-up results in 31 consecutive patients. The authors compared nonpenetrating titanium clips and expanded polytetrafluoroethylene (ePTFE) sutures in relation to the water pressure that could be tolerated by sutured ePTFE sheets, and the leakage pressure patterns were determined. The changes in leakage pressures at 5 minutes, 30 minutes, and 12 hours were examined when the clips and sutures were used in combination with the mesh-and-glue technique in an in vitro study. Thirty-one patients underwent spinal intradural procedures using nonpenetrating titanium clips to suture the dura maters using the meshand-glue technique, involving fibrin glue and polyglycolic acid-fibrin sheets. A significant difference was apparent between the ePTFE suture group and the nonpenetrating titanium clip group, with the latter showing a leakage pressure that could be sustained and was 1508% higher than that of the former (p = 0.001). In relation to leakage patterns, the nonpenetrating titanium clips did not make any suture holes in the ePTFE sheet and fluid leakage occurred between the clips, whereas fluid leakage was associated with the pressure elevation that occurred at the suture holes made by the ePTFE sutures. Of the 31 patients who underwent spinal intradural procedures using nonpenetrating titanium clips, 1 (3.2%) experienced cerebrospinal fluid (CSF) leakage postoperatively. No other complications-for example, allergic reactions, adhesions, or infections--were encountered. The interrupted placement of nonpenetrating titanium clips enables dural closure without creating any holes. These clips facilitate improvements in the initial leakage pressure and reduce postoperative CSF leakage following spinal surgery. The authors conclude that it is very beneficial to suture the spinal dura mater using nonpenetrating titanium clips given the anatomical characteristics of the spinal dura mater and the fact that the clips do not create suture holes.
Colcuc, Christian; Blank, Marc; Stein, Thomas; Raimann, Florian; Weber-Spickschen, Sanjay; Fischer, Sebastian; Hoffmann, Reinhard
2017-12-09
Suture button devices for tibiofibular syndesmosis injuries provide semirigid dynamic stabilization, but complications including knot irritation have been reported. No randomized trials of the new knotless suture button devices have been performed. We hypothesized that knotless suture button devices eliminate knot irritation and facilitate quicker return to sports. This study was performed to compare the clinical outcomes, complication rates, and time to return to sports between a new knotless suture button device and syndesmotic screw fixation. This study included 54 patients treated for ankle syndesmotic injury from 2012 to 2014 with a knotless suture button device or syndesmotic screw fixation. Clinical outcomes were measured using the American Orthopaedics Foot and Ankle Society score, Foot and Ankle Disability Index, Olerud and Molander score, and visual analog scale for pain and function. Secondary outcome measures were the complication rate and time required to return to sports. Patients underwent clinical and radiological evaluations preoperatively and three times during the 1-year postoperative follow-up. 54 of 62 eligible patients were analyzed, median age 37 (18-60) and underwent the 1-year follow-up. The screw fixation and knotless suture button groups comprised 26 and 28 patients, respectively. The complication rate was significantly lower (p = 0.03) and time to return to sports was significantly shorter in the knotless suture button than screw fixation group (average, 14 versus 19 weeks, respectively; p = 0.006). No significant differences were identified in clinical outcomes or visual analog scale scores for pain and function between the groups. Age, injury mechanism, and body mass index did not significantly affect the time required to return to sports activities. The type of fixation was the only independent variable that reached statistical significance (p = 0.006). Syndesmotic screw fixation and the new knotless suture button device both resulted in good clinical results. Lower complication rate and the earlier time to return to sports make the new knotless suture button device recommendable especially for highly active patients. Randomized controlled trial, Level I.
High-Tensile Strength Tape Versus High-Tensile Strength Suture: A Biomechanical Study.
Gnandt, Ryan J; Smith, Jennifer L; Nguyen-Ta, Kim; McDonald, Lucas; LeClere, Lance E
2016-02-01
To determine which suture design, high-tensile strength tape or high-tensile strength suture, performed better at securing human tissue across 4 selected suture techniques commonly used in tendinous repair, by comparing the total load at failure measured during a fixed-rate longitudinal single load to failure using a biomechanical testing machine. Matched sets of tendon specimens with bony attachments were dissected from 15 human cadaveric lower extremities in a manner allowing for direct comparison testing. With the use of selected techniques (simple Mason-Allen in the patellar tendon specimens, whip stitch in the quadriceps tendon specimens, and Krackow stitch in the Achilles tendon specimens), 1 sample of each set was sutured with a 2-mm braided, nonabsorbable, high-tensile strength tape and the other with a No. 2 braided, nonabsorbable, high-tensile strength suture. A total of 120 specimens were tested. Each model was loaded to failure at a fixed longitudinal traction rate of 100 mm/min. The maximum load and failure method were recorded. In the whip stitch and the Krackow-stitch models, the high-tensile strength tape had a significantly greater mean load at failure with a difference of 181 N (P = .001) and 94 N (P = .015) respectively. No significant difference was found in the Mason-Allen and simple stitch models. Pull-through remained the most common method of failure at an overall rate of 56.7% (suture = 55%; tape = 58.3%). In biomechanical testing during a single load to failure, high-tensile strength tape performs more favorably than high-tensile strength suture, with a greater mean load to failure, in both the whip- and Krackow-stitch models. Although suture pull-through remains the most common method of failure, high-tensile strength tape requires a significantly greater load to pull-through in a whip-stitch and Krakow-stitch model. The biomechanical data obtained in the current study indicates that high-tensile strength tape may provide better repair strength compared with high-tensile strength suture at time-zero simulated testing. Published by Elsevier Inc.
Stefanidis, Dimitrios; Wang, Fikre; Korndorffer, James R; Dunne, J Bruce; Scott, Daniel J
2010-02-01
Intracorporeal suturing is one of the most difficult laparoscopic tasks. The purpose of this study was to assess the impact of robotic assistance on novice suturing performance, safety, and workload in the operating room. Medical students (n = 34), without prior laparoscopic suturing experience, were enrolled in an Institutional Review Board-approved, randomized protocol. After viewing an instructional video, subjects were tested in intracorporeal suturing on two identical, live, porcine Nissen fundoplication models; they placed three gastro-gastric sutures using conventional laparoscopic instruments in one model and using robotic assistance (da Vinci) in the other, in random order. Each knot was objectively scored based on time, accuracy, and security. Injuries to surrounding structures were recorded. Workload was assessed using the validated National Aeronautics and Space Administration (NASA) task load index (TLX) questionnaire, which measures the subjects' self-reported performance, effort, frustration, and mental, physical, and temporal demands of the task. Analysis was by paired t-test; p < 0.05 was considered significant. Compared with laparoscopy, robotic assistance enabled subjects to suture faster (595 +/- 22 s versus 459 +/- 137 s, respectively; p < 0.001), achieve higher overall scores (0 +/- 1 versus 95 +/- 128, respectively; p < 0.001), and commit fewer errors per knot (1.15 +/- 1.35 versus 0.05 +/- 0.26, respectively; p < 0.001). Subjects' overall score did not improve between the first and third attempt for laparoscopic suturing (0 +/- 0 versus 0 +/- 0; p = NS) but improved significantly for robotic suturing (49 +/- 100 versus 141 +/- 152; p < 0.001). Moreover, subjects indicated on the NASA-TLX scale that the task was more difficult to perform with laparoscopic instruments compared with robotic assistance (99 +/- 15 versus 57 +/- 23; p < 0.001). Compared with standard laparoscopy, robotic assistance significantly improved intracorporeal suturing performance and safety of novices in the operating room while decreasing their workload. Moreover, the robot significantly shortened the learning curve of this difficult task. Further study is needed to assess the value of robotic assistance for experienced surgeons, and validated robotic training curricula need to be developed.
Park, Ji Soon; McGarry, Michelle H; Campbell, Sean T; Seo, Hyuk Jun; Lee, Yeon Soo; Kim, Sae Hoon; Lee, Thay Q; Oh, Joo Han
2015-09-01
Transosseous-equivalent (TOE) rotator cuff repair can increase contact area and contact pressure between the repaired cuff tendon and bony footprint and can show higher ultimate loads to failure and smaller gap formation compared with other repair techniques. However, it has been suggested that medial rotator cuff failure after TOE repair may result from increased bridging suture tension. To determine optimum bridging suture tension in TOE repair by evaluating footprint contact and construct failure characteristics at different tensions. Controlled laboratory study. A total of 18 fresh-frozen cadaveric shoulders, randomly divided into 3 groups, were constructed with a TOE configuration using the same medial suture anchor and placing a Tekscan sensing pad between the repaired rotator cuff tendon and footprint. Nine of the 18 shoulders were used to measure footprint contact characteristics. With use of the Tekscan measurement system, the contact pressure and area between the rotator cuff tendon and greater tuberosity were quantified for bridging suture tensions of 60, 90, and 120 N with glenohumeral abduction angles of 0° and 30° and humeral rotation angles of 30° (internal), 0°, and 30° (external). TOE constructs of all 18 shoulders then underwent construct failure testing (cyclic loading and load to failure) to determine the yield load, ultimate load, stiffness, hysteresis, strain, and failure mode at 60 and 120 N of tension. As bridging suture tension increased, contact force, contact pressure, and peak pressure increased significantly at all positions (P < .05 for all). Regarding contact area, no significant differences were found between 90 and 120 N at all positions, although there were significant differences between 60 and 90 N. The construct failure test demonstrated no significant differences in any parameters according to various tensions (P > .05 for all). Increasing bridging suture tension to over 90 N did not improve contact area but did increase contact force and pressure. Bridging suture tension did not significantly affect ultimate failure loads. Considering the risks of overtensioning bridging sutures, it may be clinically more beneficial to keep bridging suture tension below 90 N. © 2015 The Author(s).
Brown, Christopher A; Hurwit, Daniel; Behn, Anthony; Hunt, Kenneth J
2014-02-01
Anatomic repair is indicated for patients who have recurrent lateral ankle instability despite nonoperative measures. There is no difference in repair stiffness, failure torque, or failure angle between specimens repaired with all-soft suture anchors versus the modified Broström-Gould technique with sutures only. Controlled laboratory study. In 10 matched pairs of human cadaveric ankles, the anterior talofibular ligament (ATFL) was incised from its origin on the fibula. After randomization, 1 ankle was repaired to its anatomic insertion using two 1.4-mm JuggerKnot all-soft suture anchors; the other ankle was repaired with a modified Broström-Gould technique using 2-0 FiberWire. All were augmented using the inferior extensor retinaculum. All ankles were mounted to the testing machine in 20° of plantar flexion and 15° of internal rotation and loaded to failure after the repair. Stiffness, failure torque, and failure angle were recorded and compared using a paired Student t test with a significance level set at P < .05. There was no significant difference in failure torque, failure angle, or stiffness. No anchors pulled out of bone. The primary mode of failure was pulling through the ATFL tissue. There was no statistical difference in strength or stiffness between a 1.4-mm all-soft suture anchor and a modified Broström-Gould repair with 2-0 FiberWire. The primary mode of failure was at the tissue level rather than knot failure or anchor pullout. The particular implant choice (suture only, tunnel, anchor) in repairing the lateral ligament complex may not be as important as the time to biological healing. The suture-only construct as described in the Broström-Gould repair was as strong as all-soft suture anchors, and the majority of the ankles failed at the tissue level. For those surgeons whose preference is to use anchor repair, this novel all-soft suture anchor may be an alternative to other larger anchors, as none failed by pullout.
Primary closure versus non-closure of dog bite wounds. a randomised controlled trial.
Paschos, Nikolaos K; Makris, Eleftherios A; Gantsos, Apostolos; Georgoulis, Anastasios D
2014-01-01
Dog bite wounds represent a major health problem. Despite their importance, their management and especially the role of primary closure remain controversial. In this randomised controlled trial, the outcome between primary suturing and non-closure was compared. 168 consecutive patients with dog bite injuries were included in this study. The wounds were allocated randomly in two treatment approaches: Group 1, consisting of eighty-two patients, had their wound sutured, whilst Group 2, consisting of eighty-six patients, did not have their wounds sutured. All wounds were cleansed using high-pressure irrigation and povidone iodine. All patients received the same type of antibiotic treatment. Our measured outcomes included presence of infection and cosmetic appearance. Cosmetic outcome was evaluated using the Vancouver Scar Scale (VSS). Wound and patient characteristics, such as time of management, wound location and size, and patient age, were recorded and analysed for their potential role in the resulting outcome. The overall infection rate was 8.3%. No difference in the infection rate between primary suturing and non-suturing group was detected in the present study. The cosmetic appearance of the sutured wounds was significantly better (mean score 1.74) compared to the wounds that were left open (mean score 3.05) (p=0.0001). The infection rate was comparable among all age groups. Wounds treated within 8h of injury demonstrated an infection rate of 4.5%, which is lower compared to the 22.2% rate observed in wounds treated later than 8h. The wounds located at the head and neck exhibited better results in both infection rate and cosmetic outcome. Additionally, wounds >3 cm negatively affected the cosmetic appearance of the outcome. Primary suturing of wounds caused by dog bites resulted in similar infection rate compared to non-suturing. However, primary suturing exhibited improved cosmetic appearance. Time of management appeared to be critical, as early treatment resulted in lower infection rate and improved cosmetic appearance regardless suturing or not. Furthermore, wounds located at the head and face demonstrated better results. Copyright © 2013 Elsevier Ltd. All rights reserved.
Jiang, Huiyong; Hao, Xiuyan; Xin, Ying; Pan, Youzhen
2017-11-01
To compare the clinical outcomes of multipoint umbrella suture and single-purse suture with two-point traction after procedure for prolapse and hemorrhoids surgery (PPH) for the treatment of mixed hemorrhoids. Ninety patients were randomly divided into a PPH plus single-purse suture group (Group A) and a PPH plus multipoint umbrella suture (Group B). All operations were performed by an experienced surgeon. Operation time, width of the specimen, hemorrhoids retraction extent, postoperative pain, postoperative bleeding, and length of hospitalization were recorded and compared. Statistical analysis was conducted by t-test and χ2 test. There were no significant differences in sex, age, course of disease, and degree of prolapse of hemorrhoids between the two groups. The operative time in Group A was significantly shorter than that in Group B (P < 0.05). However, the incidence rates of submucosal hematoma and incomplete hemorrhoid core retraction were significantly lower in Group B (P < 0.05), whereas the width of the specimens in Group B was greater than that in Group A (P < 0.05). There were fewer redundant skin tags in Group B at three months follow-up. No significant difference in postoperative pain, postoperative bleeding, and time of hospital stay (P > 0.05 for all comparisons) was observed. The multipoint umbrella suture showed better clinical outcomes because of its targeted suture according to the extent of hemorrhoid prolapse. Copyright © 2017. Published by Elsevier Ltd.
Effects of In Utero Thyroxine Exposure on Murine Cranial Suture Growth
Black, Laurel; Bennfors, Grace; Parsons, Trish E.; Elsalanty, Mohammed E.; Yu, Jack C.; Weinberg, Seth M.; Cray, James J.
2016-01-01
Large scale surveillance studies, case studies, as well as cohort studies have identified the influence of thyroid hormones on calvarial growth and development. Surveillance data suggests maternal thyroid disorders (hyperthyroidism, hypothyroidism with pharmacological replacement, and Maternal Graves Disease) are linked to as much as a 2.5 fold increased risk for craniosynostosis. Craniosynostosis is the premature fusion of one or more calvarial growth sites (sutures) prior to the completion of brain expansion. Thyroid hormones maintain proper bone mineral densities by interacting with growth hormone and aiding in the regulation of insulin like growth factors (IGFs). Disruption of this hormonal control of bone physiology may lead to altered bone dynamics thereby increasing the risk for craniosynostosis. In order to elucidate the effect of exogenous thyroxine exposure on cranial suture growth and morphology, wild type C57BL6 mouse litters were exposed to thyroxine in utero (control = no treatment; low ~167 ng per day; high ~667 ng per day). Thyroxine exposed mice demonstrated craniofacial dysmorphology (brachycranic). High dose exposed mice showed diminished area of the coronal and widening of the sagittal sutures indicative of premature fusion and compensatory growth. Presence of thyroid receptors was confirmed for the murine cranial suture and markers of proliferation and osteogenesis were increased in sutures from exposed mice. Increased Htra1 and Igf1 gene expression were found in sutures from high dose exposed individuals. Pathways related to the HTRA1/IGF axis, specifically Akt and Wnt, demonstrated evidence of increased activity. Overall our data suggest that maternal exogenous thyroxine exposure can drive calvarial growth alterations and altered suture morphology. PMID:27959899
Effects of In Utero Thyroxine Exposure on Murine Cranial Suture Growth.
Howie, R Nicole; Durham, Emily L; Black, Laurel; Bennfors, Grace; Parsons, Trish E; Elsalanty, Mohammed E; Yu, Jack C; Weinberg, Seth M; Cray, James J
2016-01-01
Large scale surveillance studies, case studies, as well as cohort studies have identified the influence of thyroid hormones on calvarial growth and development. Surveillance data suggests maternal thyroid disorders (hyperthyroidism, hypothyroidism with pharmacological replacement, and Maternal Graves Disease) are linked to as much as a 2.5 fold increased risk for craniosynostosis. Craniosynostosis is the premature fusion of one or more calvarial growth sites (sutures) prior to the completion of brain expansion. Thyroid hormones maintain proper bone mineral densities by interacting with growth hormone and aiding in the regulation of insulin like growth factors (IGFs). Disruption of this hormonal control of bone physiology may lead to altered bone dynamics thereby increasing the risk for craniosynostosis. In order to elucidate the effect of exogenous thyroxine exposure on cranial suture growth and morphology, wild type C57BL6 mouse litters were exposed to thyroxine in utero (control = no treatment; low ~167 ng per day; high ~667 ng per day). Thyroxine exposed mice demonstrated craniofacial dysmorphology (brachycranic). High dose exposed mice showed diminished area of the coronal and widening of the sagittal sutures indicative of premature fusion and compensatory growth. Presence of thyroid receptors was confirmed for the murine cranial suture and markers of proliferation and osteogenesis were increased in sutures from exposed mice. Increased Htra1 and Igf1 gene expression were found in sutures from high dose exposed individuals. Pathways related to the HTRA1/IGF axis, specifically Akt and Wnt, demonstrated evidence of increased activity. Overall our data suggest that maternal exogenous thyroxine exposure can drive calvarial growth alterations and altered suture morphology.