Sample records for sweating threshold temperature

  1. Doxapram Only Slightly Reduces the Shivering Threshold in Healthy Volunteers

    PubMed Central

    Komatsu, Ryu; Sengupta, Papiya; Cherynak, Grigory; Wadhwa, Anupama; Sessler, Daniel I.; Liu, Jin; Hurst, Harrell E.; Lenhardt, Rainer

    2005-01-01

    We determined the effects of doxapram on the major autonomic thermoregulatory responses in humans. Nine healthy volunteers were studied on two days: Control and Doxapram (intravenous infusion to a plasma concentration of 2.4 ±0.8 μg/mL, 2.5 ±0.9 μg/mL, and 2.6 ±1.1 μg/mL at the sweating, vasoconstriction, and shivering thresholds, respectively). Each day, skin and core temperatures were increased to provoke sweating, then reduced to elicit peripheral vasoconstriction and shivering. We determined the sweating, vasoconstriction, and shivering thresholds with compensation for changes in skin temperature. Data were analyzed with paired t tests and presented as means ± SDs; P < 0.05 was considered statistically significant. Doxapram did not change the sweating (Control: 37.5±0.4°C, Doxapram: 37.3±0.4°C, P=0.290) or the vasoconstriction threshold (36.8±0.7 vs. 36.4±0.5°C; P=0.110). However, it significantly reduced the shivering threshold from 36.2±0.5 to 35.7±0.7°C (P=0.012). No sedation or symptoms of panic were observed on either study day. The observed reduction in the shivering threshold explains the drug's efficacy for treatment of postoperative shivering; however, a reduction of only 0.5°C is unlikely to markedly facilitate induction of therapeutic hypothermia as a sole agent. PMID:16243996

  2. Effect of voluntary hypocapnic hyperventilation on the relationship between core temperature and heat loss responses in exercising humans.

    PubMed

    Fujii, Naoto; Honda, Yasushi; Komura, Ken; Tsuji, Bun; Sugihara, Akira; Watanabe, Kazuhito; Kondo, Narihiko; Nishiyasu, Takeshi

    2014-12-01

    Two thermolytic thermoregulatory responses, cutaneous vasodilation and sweating, begin when core temperature reaches a critical threshold, after which response magnitudes increase linearly with increasing core temperature; thus the slope indicates response sensitivity. We evaluated the influence of hypocapnia induced by voluntary hyperventilation on the core temperature threshold and sensitivity of thermoregulatory responses. Ten healthy males performed 15 min of cycling at 117 W (29.5°C, 50% RH) under three breathing conditions: 1) spontaneous ventilation, 2) voluntary normocapnic hyperventilation, and 3) voluntary hypocapnic hyperventilation. In the hypocapnic hyperventilation trial, end-tidal CO2 pressure was reduced throughout the exercise, whereas it was maintained around the normocapnic level in the other two trials. Cutaneous vascular conductances at the forearm and forehead were evaluated as laser-Doppler signal/mean arterial blood pressure, and the forearm sweat rate was measured using the ventilated capsule method. Esophageal temperature threshold was higher for the increase in cutaneous vascular conductance in the hypocapnic than normocapnic hyperventilation trial at the forearm (36.88 ± 0.36 vs. 36.68 ± 0.34°C, P < 0.05) and forehead (36.89 ± 0.31 vs. 36.75 ± 0.31°C, P < 0.05). The slope relating esophageal temperature to cutaneous vascular conductance was decreased in the hypocapnic than normocapnic hyperventilation trial at the forearm (302 ± 177 vs. 420 ± 178% baseline/°C, P < 0.05) and forehead (236 ± 164 vs. 358 ± 221% baseline/°C, P < 0.05). Neither the threshold nor the slope for the forearm sweat rate differed significantly between the hypocapnic or normocapnic hyperventilation trials. These findings indicate that in exercising humans, hypocapnia induced by voluntary hyperventilation does not influence sweating, but it attenuates the cutaneous vasodilatory response by increasing its threshold and reducing its sensitivity. Copyright © 2014 the American Physiological Society.

  3. Nefopam, a Non-sedative Benzoxazocine Analgesic, Selectively Reduces the Shivering Threshold

    PubMed Central

    Alfonsi, Pascal; Adam, Frederic; Passard, Andrea; Guignard, Bruno; Sessler, Daniel I.; Chauvin, Marcel

    2005-01-01

    Background The analgesic nefopam does not compromise ventilation, is minimally sedating, and is effective as a treatment for postoperative shivering. We evaluated the effects of nefopam on the major thermoregulatory responses in humans: sweating, vasoconstriction, and shivering. Methods Nine volunteers were studied on three randomly assigned days: 1) control (Saline), 2) nefopam at a target plasma concentration of 35 ng/ml (Small Dose), and 3) nefopam at a target concentration of 70 ng/ml (Large Dose, ≈20 mg total). Each day, skin and core temperatures were increased to provoke sweating and then reduced to elicit peripheral vasoconstriction and shivering. We determined the thresholds (triggering core temperature at a designated skin temperature of 34°C) by mathematically compensating for changes in skin temperature using the established linear cutaneous contributions to control of each response. Results Nefopam did not significantly modify the slopes for sweating (0.0 ± 4.9°C·μg−1·ml; r2 = 0.73 ± 0.32) or vasoconstriction (−3.6 ± 5.0°C·μg−1·ml; r2=−0.47± 0.41). In contrast, nefopam significantly reduced the slope of shivering (−16.8 ± 9.3°C·μg−1·ml; r2 = 0.92 ± 0.06). Large-Dose nefopam thus reduced the shivering threshold by 0.9 ± 0.4°C (P<0.001) without any discernable effect on the sweating or vasoconstriction thresholds. Conclusions Most drugs with thermoregulatory actions — including anesthetics, sedatives, and opioids — synchronously reduce the vasoconstriction and shivering thresholds. Nefopam however reduced only the shivering threshold. This pattern has not previously been reported for a centrally acting drug. That pharmacologic modulation of vasoconstriction and shivering can be separated is of clinical and physiologic interest. PMID:14695722

  4. Dantrolene Reduces the Threshold and Gain for Shivering

    PubMed Central

    Lin, Chun-Ming; Neeru, Sharma; Doufas, Anthony G.; Liem, Edwin; Shah, Yunus Muneer; Wadhwa, Anupama; Lenhardt, Rainer; Bjorksten, Andrew; Kurz, Andrea

    2005-01-01

    Dantrolene is used for treatment of life-threatening hyperthermia, yet its thermoregulatory effects are unknown. We tested the hypothesis that dantrolene reduces the threshold (triggering core temperature) and gain (incremental increase) of shivering. With IRB approval and informed consent, healthy volunteers were evaluated on two random days: control and dantrolene (≈2.5 mg/kg plus a continuous infusion). In study 1, 9 men were warmed until sweating was provoked and then cooled until arterio-venous shunt constriction and shivering occurred. Sweating was quantified on the chest using a ventilated capsule. Absolute right middle fingertip blood flow was quantified using venous-occlusion volume plethysmography. A sustained increase in oxygen consumption identified the shivering threshold. In study 2, 9 men were given cold Ringer's solution IV to reduce core temperature ≈2°C/h. Cooling was stopped when shivering intensity no longer increased with further core cooling. The gain of shivering was the slope of oxygen consumption vs. core temperature regression. In Study 1, sweating and vasoconstriction thresholds were similar on both days. In contrast, shivering threshold decreased 0.3±0.3°C, P=0.004, on the dantrolene day. In Study 2, dantrolene decreased the shivering threshold from 36.7±0.2 to 36.3±0.3°C, P=0.01 and systemic gain from 353±144 to 211±93 ml·min−1·°C−1, P=0.02. Thus, dantrolene substantially decreased the gain of shivering, but produced little central thermoregulatory inhibition. PMID:15105208

  5. Tramadol reduces the sweating, vasoconstriction, and shivering thresholds.

    PubMed

    De Witte, J L; Kim, J S; Sessler, D I; Bastanmehr, H; Bjorksten, A R

    1998-07-01

    The analgesic tramadol inhibits the neuronal reuptake of norepinephrine and 5-hydroxytryptamine, facilitates 5-hydroxytryptamine release, and activates mu-opioid receptors. Each of these actions is likely to influence thermoregulatory control. We therefore tested the hypothesis that tramadol inhibits thermoregulatory control. Eight volunteers were evaluated on four study days, on which they received no drugs, tramadol 125 mg, tramadol 250 mg, and tramadol 250 mg with naloxone, respectively. Skin and core temperatures were gradually increased until sweating was observed and then decreased until vasoconstriction and shivering were detected. The core temperature triggering each response defined its threshold. Tramadol decreased the sweating threshold by -1.03 +/- 0.67 degrees C microgram-1.mL (r2 = 0.90 +/- 0.12). Tramadol also decreased the vasoconstriction threshold by -3.0 +/- 4.0 degrees C microgram-1.mL (r2 = 0.94 +/- 0.98) and the shivering threshold by -4.2 +/- 4.0 degrees C microgram-1.mL(r2 = 0.98 +/- 0.98). The sweating to vasoconstriction interthreshold range nearly doubled from 0.3 +/- 0.4 degree C to 0.7 +/- 0.6 degree C during the administration of large-dose tramadol (P = 0.04). The addition of naloxone only partially reversed the thermoregulatory effects of tramadol. The thermoregulatory effects of tramadol thus most resemble those of midazolam, another drug that slightly decreases the thresholds triggering all three major autonomic thermoregulatory defenses. In this respect, both drugs reduce the "setpoint" rather than produce a generalized impairment of thermoregulatory control. Nonetheless, tramadol nearly doubled the interthreshold range at a concentration near 200 ng/mL. This indicates that tramadol slightly decreases the precision of thermoregulatory control in addition to reducing the setpoint. The authors evaluated the effects of the analgesic tramadol on the three major thermoregulatory responses: sweating, vasoconstriction, and shivering. Tramadol had only slight thermoregulatory effects. Its use is thus unlikely to provoke hypothermia or to facilitate fever.

  6. Thermoregulatory defense mechanisms.

    PubMed

    Sessler, Daniel I

    2009-07-01

    Core body temperature is normally tightly regulated by an effective thermoregulatory system. Thermoregulatory control is sometimes impaired by serious illness, but more typically remains intact. The primary autonomic defenses against heat are sweating and active precapillary vasodilation; the primary autonomic defenses against cold are arteriovenous shunt vasoconstriction and shivering. The core temperature triggering each response defines its activation threshold. Temperatures between the sweating and vasoconstriction thresholds define the inter-threshold range. The shivering threshold is usually a full 1 degrees C below the vasoconstriction threshold and is therefore a "last resort" response. Both vasoconstriction and shivering are associated with autonomic and hemodynamic activation; and each response is effective, thus impeding induction of therapeutic hypothermia. It is thus helpful to accompany core cooling with drugs that pharmacologically induce a degree of thermal tolerance. No perfect drug or drug combination has been identified. Anesthetics, for example, induce considerable tolerance, but are rarely suitable. Meperidine-especially in combination with buspirone-is especially effective while provoking only modest toxicity. The combination of buspirone and dexmedetomidine is comparably effective while avoiding the respiratory depression association with opioid administration.

  7. Objective evaluation of cutaneous thermal sensivity

    NASA Technical Reports Server (NTRS)

    Vanbeaumont, W.

    1972-01-01

    The possibility of obtaining reliable and objective quantitative responses was investigated under conditions where only temperature changes in localized cutaneous areas evoked measurable changes in remote sudomotor activity. Both male and female subjects were studied to evaluate sex difference in thermal sensitivity. The results discussed include: sweat rate responses to contralateral cooling, comparison of sweat rate responses between men and women to contralateral cooling, influence of the menstrual cycle on the sweat rate responses to contralateral cooling, comparison of threshold of sweating responses between men and women, and correlation of latency to threshold for whole body sweating. It is concluded that the quantitative aspects of the reflex response is affected by both the density and activation of receptors as well as the rate of heat loss; men responded 8-10% more frequently than women to thermode cooling, the magnitude of responses being greater for men; and women responded 7-9% more frequently to thermode cooling on day 1 of menstruation, as compared to day 15.

  8. FDTD computation of temperature elevation in the elderly for far-field RF exposures.

    PubMed

    Nomura, Tomoki; Laakso, Ilkka; Hirata, Akimasa

    2014-03-01

    Core temperature elevation and perspiration in younger and older adults is investigated for plane-wave exposure at whole-body averaged specific absorption rate of 0.4 W kg(-1). Numeric Japanese male model is considered together with a thermoregulatory response formula proposed in the authors' previous study. The frequencies considered were at 65 MHz and 2 GHz where the total power absorption in humans becomes maximal for the allowable power density prescribed in the international guidelines. From the computational results used here, the core temperature elevation in the older adult model was larger than that in the younger one at both frequencies. The reason for this difference is attributable to the difference of sweating, which is originated from the difference in the threshold activating the sweating and the decline in sweating in the legs.

  9. Thermoregulation and thermal perception in the cold and heat before and after intermittent heat adaptation

    NASA Astrophysics Data System (ADS)

    Issing, K.; Fuhr, E.

    1986-09-01

    Students wearing swim suits were exposed for 30 min to neutral room temperature (TR=28‡C). During the following 60 min they were subjected to gradual decreases or increases of room temperature reaching 12‡C or 45‡C, respectively. Static thermal stimuli were applied to the palms of the right (38‡C) and left (25‡C) hands. Hands and feet of all subjects were thermally isolated at 22‡C ambient temperature. General thermal comfort (GTC), local thermal comfort (LTC), skin blood flow (which is proportional to heat transport index λ) several body temperatures, oxygen-consumption(dot V_{O_2 } ), and sweat rate (S), were measured. After moderate intermittent heat exposures (7 times for 1h at TR=42.5‡C) the experiments started again. From GTC, LTC, or λ as functions of TR, no new knowledge about thermoregulatory or adaptive mechanisms was available. The high λ in the cold stimulated left hand, however, and the oscillatory thresholds (λOSC) for rhythmic vasomotion indicated the peripheral influence of skin temperature, as well as local, mean skin temperature (¯Ts) and core temperature. When exposed to moderate temperature decreases or increases the body seems to react only with increasing thermal resistance by vasoconstriction or an increase of sweat rate, respectively. Moderate heat adaptation is only able to raise sweat rate, but not the thresholds and gain of the S-function. We assume that functional studies of adaptive modifications in humans must be conducted at temperatures greatly beyond those used in these experiments.

  10. Exercise training reduces the frequency of menopausal hot flushes by improving thermoregulatory control.

    PubMed

    Bailey, Tom G; Cable, N Timothy; Aziz, Nabil; Dobson, Rebecca; Sprung, Victoria S; Low, David A; Jones, Helen

    2016-07-01

    Postmenopausal hot flushes occur due to a reduction in estrogen production causing thermoregulatory and vascular dysfunction. Exercise training enhances thermoregulatory control of sweating, skin and brain blood flow. We aimed to determine if improving thermoregulatory control and vascular function with exercise training alleviated hot flushes. Twenty-one symptomatic women completed a 7-day hot flush questionnaire and underwent brachial artery flow-mediated dilation and a cardiorespiratory fitness test. Sweat rate and skin blood flow temperature thresholds and sensitivities, and middle cerebral artery velocity (MCAv) were measured during passive heating. Women performed 16 weeks of supervised exercise training or control, and measurements were repeated. There was a greater improvement in cardiorespiratory fitness (4.45 mL/kg/min [95% CI: 1.87, 8.16]; P = 0.04) and reduced hot flush frequency (48 hot flushes/wk [39, 56]; P < 0.001) after exercise compared with control. Exercise reduced basal core temperature (0.14°C [0.01, 0.27]; P = 0.03) and increased basal MCAv (2.8 cm/s [1.0, 5.2]; P = 0.04) compared with control. Sweat rate and skin blood flow thresholds occurred approximately 0.19°C and 0.17°C earlier, alongside improved sweating sensitivity with exercise. MCAv decreased during heating (P < 0.005), but was maintained 4.5 cm/s (3.6, 5.5; P < 0.005) higher during heating after exercise compared with control (0.6 cm/s [-0.4, 1.4]). Exercise training that improves cardiorespiratory fitness reduces self-reported hot flushes. Improvements are likely mediated through greater thermoregulatory control in response to increases in core temperature and enhanced vascular function in the cutaneous and cerebral circulations.

  11. Tactile cues significantly modulate the perception of sweat-induced skin wetness independently of the level of physical skin wetness

    PubMed Central

    Fournet, Damien; Hodder, Simon; Havenith, George

    2015-01-01

    Humans sense the wetness of a wet surface through the somatosensory integration of thermal and tactile inputs generated by the interaction between skin and moisture. However, little is known on how wetness is sensed when moisture is produced via sweating. We tested the hypothesis that, in the absence of skin cooling, intermittent tactile cues, as coded by low-threshold skin mechanoreceptors, modulate the perception of sweat-induced skin wetness, independently of the level of physical wetness. Ten males (22 yr old) performed an incremental exercise protocol during two trials designed to induce the same physical skin wetness but to induce lower (TIGHT-FIT) and higher (LOOSE-FIT) wetness perception. In the TIGHT-FIT, a tight-fitting clothing ensemble limited intermittent skin-sweat-clothing tactile interactions. In the LOOSE-FIT, a loose-fitting ensemble allowed free skin-sweat-clothing interactions. Heart rate, core and skin temperature, galvanic skin conductance (GSC), and physical (wbody) and perceived skin wetness were recorded. Exercise-induced sweat production and physical wetness increased significantly [GSC: 3.1 μS, SD 0.3 to 18.8 μS, SD 1.3, P < 0.01; wbody: 0.26 no-dimension units (nd), SD 0.02, to 0.92 nd, SD 0.01, P < 0.01], with no differences between TIGHT-FIT and LOOSE-FIT (P > 0.05). However, the limited intermittent tactile inputs generated by the TIGHT-FIT ensemble reduced significantly whole-body and regional wetness perception (P < 0.01). This reduction was more pronounced when between 40 and 80% of the body was covered in sweat. We conclude that the central integration of intermittent mechanical interactions between skin, sweat, and clothing, as coded by low-threshold skin mechanoreceptors, significantly contributes to the ability to sense sweat-induced skin wetness. PMID:25878153

  12. Continuous measurement of tympanic temperature with a new infrared method using an optical fiber.

    PubMed

    Shibasaki, M; Kondo, N; Tominaga, H; Aoki, K; Hasegawa, E; Idota, Y; Moriwaki, T

    1998-09-01

    The purpose of this study was to investigate the utility of an infrared tympanic thermometry by using an optical fiber for measuring tympanic temperature (Tty). In the head cooling and facial fanning tests during normothermia, right Tty measured by this method (infrared-Tty) and esophageal temperature (Tes) were not affected by decreased temple and forehead skin temperatures, suggesting that the infrared sensor in this system measured the infrared radiation from the tympanic membrane selectively. Eight male subjects took part in passive-heat-stress and progressive-exercise tests. No significant differences among infrared-Tty, the left Tty measured by thermistor (contact-Tty), and Tes were observed at rest or at the end of each experiment, and there was no significant difference in the increase in these core temperatures from rest to the end. Furthermore, there were no significant differences in the core temperature threshold at the onset of sweating and slope (the relationship of sweating rate vs. infrared-Tty and vs. contact-Tty). These results suggest that this method makes it possible to measure Tty accurately, continuously, and more safely.

  13. Oral intake of encapsulated dried ginger root powder hardly affects human thermoregulatory function, but appears to facilitate fat utilization

    NASA Astrophysics Data System (ADS)

    Miyamoto, Mayumi; Matsuzaki, Kentaro; Katakura, Masanori; Hara, Toshiko; Tanabe, Yoko; Shido, Osamu

    2015-10-01

    The present study investigated the impact of a single oral ingestion of ginger on thermoregulatory function and fat oxidation in humans. Morning and afternoon oral intake of 1.0 g dried ginger root powder did not alter rectal temperature, skin blood flow, O2 consumption, CO2 production, and thermal sensation and comfort, or induce sweating at an ambient temperature of 28 °C. Ginger ingestion had no effect on threshold temperatures for skin blood flow or thermal sweating. Serum levels of free fatty acids were significantly elevated at 120 min after ginger ingestion in both the morning and afternoon. Morning ginger intake significantly reduced respiratory exchange ratios and elevated fat oxidation by 13.5 % at 120 min after ingestion. This was not the case in the afternoon. These results suggest that the effect of a single oral ginger administration on the peripheral and central thermoregulatory function is miniscule, but does facilitate fat utilization although the timing of the administration may be relevant.

  14. Oral intake of encapsulated dried ginger root powder hardly affects human thermoregulatory function, but appears to facilitate fat utilization.

    PubMed

    Miyamoto, Mayumi; Matsuzaki, Kentaro; Katakura, Masanori; Hara, Toshiko; Tanabe, Yoko; Shido, Osamu

    2015-10-01

    The present study investigated the impact of a single oral ingestion of ginger on thermoregulatory function and fat oxidation in humans. Morning and afternoon oral intake of 1.0 g dried ginger root powder did not alter rectal temperature, skin blood flow, O2 consumption, CO2 production, and thermal sensation and comfort, or induce sweating at an ambient temperature of 28 °C. Ginger ingestion had no effect on threshold temperatures for skin blood flow or thermal sweating. Serum levels of free fatty acids were significantly elevated at 120 min after ginger ingestion in both the morning and afternoon. Morning ginger intake significantly reduced respiratory exchange ratios and elevated fat oxidation by 13.5 % at 120 min after ingestion. This was not the case in the afternoon. These results suggest that the effect of a single oral ginger administration on the peripheral and central thermoregulatory function is miniscule, but does facilitate fat utilization although the timing of the administration may be relevant.

  15. Precise measurement of volume of eccrine sweat gland in mental sweating by optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Sugawa, Yoshihiko; Fukuda, Akihiro; Ohmi, Masato

    2015-04-01

    We have demonstrated dynamic analysis of the physiological function of eccrine sweat glands underneath skin surface by optical coherence tomography (OCT). In this paper, we propose a method for extraction of the specific eccrine sweat gland by means of the connected component extraction process and the adaptive threshold method, where the en face OCT images are constructed by the swept-source OCT. In the experiment, we demonstrate precise measurement of the volume of the sweat gland in response to the external stimulus.

  16. Precise measurement of instantaneous volume of eccrine sweat gland in mental sweating by optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Sugawa, Yoshihiko; Fukuda, Akihiro; Ohmi, Masato

    2015-03-01

    We have demonstrated dynamic analysis of the physiological function of eccrine sweat glands underneath skin surface by optical coherence tomography (OCT). We propose a method for extraction of the target eccrine sweat gland by use of the connected component extraction process and the adaptive threshold method, where the en-face OCT images are constructed by the SS-OCT. Furthermore, we demonstrate precise measurement of instantaneous volume of the sweat gland in response to the external stimulus. The dynamic change of instantaneous volume of eccrine sweat gland in mental sweating is performed by this method during the period of 300 sec with the frame intervals of 3.23 sec.

  17. Wearing graduated compression stockings augments cutaneous vasodilation but not sweating during exercise in the heat.

    PubMed

    Fujii, Naoto; Nikawa, Toshiya; Tsuji, Bun; Kenny, Glen P; Kondo, Narihiko; Nishiyasu, Takeshi

    2017-05-01

    The activation of cutaneous vasodilation and sweating are essential to the regulation of core temperature during exercise in the heat. We assessed the effect of graduated compression induced by wearing stockings on cutaneous vasodilation and sweating during exercise in the heat (30°C). On two separate occasions, nine young males exercised for 45 min or until core temperature reached ~1.5°C above baseline resting while wearing either (1) stockings causing graduated compression (graduate compression stockings, GCS), or (2) loose-fitting stockings without compression (Control). Forearm vascular conductance was evaluated by forearm blood flow (venous occlusion plethysmography) divided by mean arterial pressure to estimate cutaneous vasodilation. Sweat rate was estimated using the ventilated capsule technique. Core and skin temperatures were measured continuously. Exercise duration was similar between conditions (Control: 42.2 ± 3.6 min vs. GCS: 42.2 ± 3.6 min, P  = 1.00). Relative to Control, GCS increased forearm vascular conductance during the late stages (≥30 min) of exercise (e.g., at 40 min, 15.6 ± 5.6 vs. 18.0 ± 6.0 units, P  = 0.01). This was paralleled by a greater sensitivity (23.1 ± 9.1 vs. 32.1 ± 15.0 units°C -1 , P  = 0.043) and peak level (14.1 ± 5.1 vs. 16.3 ± 5.7 units, P  = 0.048) of cutaneous vasodilation as evaluated from the relationship between forearm vascular conductance with core temperature. However, the core temperature threshold at which an increase in forearm vascular conductance occurred did not differ between conditions (Control: 36.9 ± 0.2 vs. GCS: 37.0 ± 0.3°C, P  = 0.13). In contrast, no effect of GCS on sweating was measured (all P  > 0.05). We show that the use of GCS during exercise in the heat enhances cutaneous vasodilation and not sweating. © 2017 The Authors. Physiological Reports published by Wiley Periodicals, Inc. on behalf of The Physiological Society and the American Physiological Society.

  18. Effect of skin temperature on the cholinergic sensitivity of the human eccrine sweat gland.

    PubMed

    DiPasquale, Dana M; Buono, Michael J; Kolkhorst, Fred W

    2003-12-01

    Although sweat gland activity is directly controlled by the central nervous system, which detects changes in core body temperature, sweat glands can also be influenced by local cutaneous thermal conditions. The present study sought to determine the effect of local skin temperature on pilocarpine-induced sweating within a range of typical skin temperatures. Thirteen subjects (30 +/- 6 years; 172 +/- 11 cm; 72.8 +/- 11.0 kg) had forearm sweat rates measured at rest following pilocarpine iontophoresis at each of three skin temperatures in randomized order: warm (T(warm) = 37.1 +/- 0.9 degrees C), control (T(con) = 32.3 +/- 1.4 degrees C), and cool (T(cool) = 26.6 +/- 1.3 degrees C). T(skin) was raised and lowered with an electric heating pad and gel ice pack, respectively. Forearm T(skin) was measured with a skin temperature probe. Pilocarpine iontophoresis was used on an approximately 7 cm(2) area of the anterior forearm to stimulate localized sweating. Following stimulation, sweat was collected from the area for 15 min with a Macroduct Sweat Collection System. There was a higher sweat rate at T(warm) (p = 0.001) and T(con) (p = 0.006) compared to that at T(cool). However, there was no difference between the sweat rate at T(warm) and that at T(con) (p = 0.127). These results indicated that skin temperatures below approximately 32 degrees C affect local sweat production primarily by altering glandular sensitivity to the neurotransmitter, whereas skin temperatures above approximately 32 degrees C predominantly affect neurotransmitter release. Furthermore, sweat glands display maximal or near maximal cholinergic sensitivity at resting skin temperature in a thermoneutral environment.

  19. Tropical Malaysians and temperate Koreans exhibit significant differences in sweating sensitivity in response to iontophoretically administered acetylcholine

    NASA Astrophysics Data System (ADS)

    Lee, Jeong-Beom; Bae, Jun-Sang; Matsumoto, Takaaki; Yang, Hun-Mo; Min, Young-Ki

    2009-03-01

    Natives of the tropics are able to tolerate high ambient temperatures. This results from their long-term residence in hot and often humid tropical climates. This study was designed to compare the peripheral mechanisms of thermal sweating in tropical natives with that of their temperate counterparts. Fifty-five healthy male subjects including 20 native Koreans who live in the temperate Korean climate (Temperate-N) and 35 native tropical Malaysian men that have lived all of their lives in Malaysia (Tropical-N) were enrolled in this study after providing written informed consent to participate. Quantitative sudomotor axon reflex testing after iontophoresis (2 mA for 5 min) with 10% acetylcholine (ACh) was used to determine directly activated (DIR) and axon reflex-mediated (AXR) sweating during ACh iontophoresis. The sweat rate, activated sweat gland density, sweat gland output per single gland activated, and oral and skin temperature changes were measured. The sweat onset time of AXR (nicotinic-receptor-mediated) was 56 s shorter in the Temperate-N than in the Tropical-N subjects ( P < 0.0001). The nicotinic-receptor-mediated sweating activity AXR (1), and the muscarinic-receptor-mediated sweating activity DIR, in terms of sweat volume, were 103% and 59% higher in the Temperate-N compared to the Tropical-N subjects ( P < 0.0001). The Temperate-N group also had a 17.8% ( P < 0.0001) higher active sweat gland density, 35.4% higher sweat output per gland, 0.24°C higher resting oral temperature, and 0.62°C higher resting forearm skin temperature compared to the Tropical-N subjects ( P < 0.01). ACh iontophoresis did not influence oral temperature, but increased skin temperature near where the ACh was administered, in both groups. These results suggest that suppressed thermal sweating in the Tropical-N subjects was, at least in part, due to suppressed sweat gland sensitivity to ACh through both recruitment of active sweat glands and the sweat gland output per each gland. This physiological trait guarantees a more economical use of body fluids, thus ensuring more efficient protection against heat stress.

  20. Modification of cutaneous vasodilator response to heat stress by daytime exogenous melatonin administration.

    PubMed

    Aoki, Ken; Stephens, Dan P; Zhao, Kun; Kosiba, Wojciech A; Johnson, John M

    2006-09-01

    In humans, the nocturnal fall in internal temperature is associated with increased endogenous melatonin and with a shift in the thermoregulatory control of skin blood flow (SkBF), suggesting a role for melatonin in the control of SkBF. The purpose of this study was to test whether daytime exogenous melatonin would shift control of SkBF to lower internal temperatures during heat stress, as is seen at night. Healthy male subjects (n = 8) underwent body heating with melatonin administration (Mel) or without (control), in random order at least 1 wk apart. SkBF was monitored at sites pretreated with bretylium to block vasoconstrictor nerve function and at untreated sites. Cutaneous vascular conductance, calculated from SkBF and arterial pressure, sweating rate (SR), and heart rate (HR) were monitored. Skin temperature was elevated to 38 degrees C for 35-50 min. Baseline esophageal temperature (Tes) was lower in Mel than in control (P < 0.01). The Tes threshold for cutaneous vasodilation and the slope of cutaneous vascular conductance with respect to Tes were also lower in Mel at both untreated and bretylium-treated sites (P < 0.05). The Tes threshold for the onset of sweating and the Tes for a standard HR were reduced in Mel. The slope of the relationship of HR, but not SR, to Tes was lower in Mel (P < 0.05). These findings suggest that melatonin affects the thermoregulatory control of SkBF during hyperthermia via the cutaneous active vasodilator system. Because control of SR and HR are also modified, a central action of melatonin is suggested.

  1. Effects of catechin-enriched ion beverage intake on thermoregulatory function in a hot environment.

    PubMed

    Nishimura, Rumiko; Nishimura, Naoki; Iwase, Satoshi; Takeshita, Masao; Katashima, Mitsuhiro; Katsuragi, Yoshihisa; Sato, Motohiko

    2018-04-23

    We examined the effect of intake of a catechin-enriched ion beverage (Cat-I) on the thermoregulatory response in a hot environment. Eight healthy men were exposed to a hot environment for 90 min at an ambient temperature of 35 °C (relative humidity: 75%) combined with lower leg water immersion at 40 °C. At that time, either Cat-I, an ion beverage (Ion), or mineral water (Placebo) was consumed at three points: (1) at the start of lower leg immersion, (2) at 30 min after immersion, and (3) at 60 min after immersion. In all conditions, tympanic temperature (Tty) increased gradually during lower leg water immersion. However, the rate of increase of Tty tended to be suppressed after 30 min. The effect of drinking Cat-I had a limited detection period of approximately 60-70 min, and the rate of sweating was clearly increased with Cat-I compared with Ion and Placebo. Cat-I also tended to decrease the body temperature threshold at which sweating was induced compared with Ion or Placebo. These findings suggest that Cat-I efficiently suppressed the increase of body temperature in a hot environment.

  2. Regional differences in sweat rate response of steers to short-term heat stress

    NASA Astrophysics Data System (ADS)

    Scharf, B.; Wax, L. E.; Aiken, G. E.; Spiers, D. E.

    2008-11-01

    Six Angus steers (319 ± 8.5 kg) were assigned to one of two groups (hot or cold exposure) of three steers each, and placed into two environmental chambers initially maintained at 16.5-18.8°C air temperature ( T a). Cold chamber T a was lowered to 8.4°C, while T a within the hot chamber was increased to 32.7°C over a 24-h time period. Measurements included respiration rate, and air and body (rectal and skin) temperatures. Skin temperature was measured at shoulder and rump locations, with determination of sweat rate using a calibrated moisture sensor. Rectal temperature did not change in cold or hot chambers. However, respiration rate nearly doubled in the heat ( P < 0.05), increasing when T a was above 24°C. Skin temperatures at the two locations were highly correlated ( P < 0.05) with each other and with T a. In contrast, sweat rate showed differences at rump and shoulder sites. Sweat rate of the rump exhibited only a small increase with T a. However, sweat rate at the shoulder increased more than four-fold with increasing T a. Increased sweat rate in this region is supported by an earlier report of a higher density of sweat glands in the shoulder compared to rump regions. Sweat rate was correlated with several thermal measurements to determine the best predictor. Fourth-order polynomial expressions of short-term rectal and skin temperature responses to hot and cold exposures produced r values of 0.60, 0.84, and 0.98, respectively. These results suggest that thermal inputs other than just rectal or skin temperature drive the sweat response in cattle.

  3. Effect of estrogen supplementation on exercise thermoregulation in premenopausal women.

    PubMed

    Chang, R T; Lambert, G P; Moseley, P L; Chapler, F K; Gisolfi, C V

    1998-12-01

    This study examined the effects of 3 days of estrogen supplementation (ES) on thermoregulation during exercise in premenopausal (20-39 yr) adult women during the follicular phase of the menstrual cycle. Subjects (11 control, 10 experimental) performed upright cycle ergometer exercise at 60% of maximal O2 consumption in a neutral environment (25 degreesC, 30% relative humidity) for 20 min. Subjects were given placebo (P) or beta-estradiol (2 mg/tablet, 3 tablets/day for 3 days). All experiments were conducted between 6:30 and 9:00 AM after ingestion of the last tablet. Heart rate, forearm blood flow (FBF), mean skin temperature, esophageal temperature (Tes), and forearm sweat rate were measured. Blood analysis for estrogen and progesterone reflected the follicular phase of the menstrual cycle. Maximal O2 consumption (37.1 +/- 6.2 in P vs. 38.4 +/- 6.3 ml. kg-1. min-1 in ES) and body weight-to-surface area ratio (35.58 +/- 2.85 in P vs. 37.3 +/- 2.7 in ES) were similar between groups. Synthesis of 70-kDa heat shock protein was not induced by 3 days of ES. Neither the threshold for sweating (36.97 +/- 0.15 in P vs. 36.90 +/- 0.22 degreesC in ES), the threshold for an increase in FBF (37.09 +/- 0. 22 in P vs. 37.17 +/- 0.26 degreesC in ES), the slope of sweat rate-Tes relationship (0.42 +/- 0.16 in P vs. 0.41 +/- 0.17 in ES), nor the FBF-Tes relationship (10.04 +/- 4.4 in P vs. 9.61 +/- 3.46 in ES) was affected (P > 0.05) by 3 days of ES. We conclude that 3 days of ES by young adult women in the follicular phase of their menstrual cycle have no effect on heat transfer to the skin, heat dissipation by evaporative cooling, or leukocyte synthesis of 70-kDa heat shock protein.

  4. Role of skin blood flow and sweating rate in exercise thermoregulation after bed rest

    NASA Technical Reports Server (NTRS)

    Lee, Stuart M C.; Williams, W. Jon; Schneider, Suzanne M.

    2002-01-01

    Two potential mechanisms, reduced skin blood flow (SBF) and sweating rate (SR), may be responsible for elevated intestinal temperature (T(in)) during exercise after bed rest and spaceflight. Seven men underwent 13 days of 6 degrees head-down bed rest. Pre- and post-bed rest, subjects completed supine submaximal cycle ergometry (20 min at 40% and 20 min at 65% of pre-bed rest supine peak exercise capacity) in a thermoneutral room. After bed rest, T(in) was elevated at rest (+0.31 +/- 0.12 degrees C) and at the end of exercise (+0.33 +/- 0.07 degrees C). Percent increase in SBF during exercise was less after bed rest (211 +/- 53 vs. 96 +/- 31%; P < or = 0.05), SBF/T(in) threshold was greater (37.09 +/- 0.16 vs. 37.33 +/- 0.13 degrees C; P < or = 0.05), and slope of SBF/T(in) tended to be reduced (536 +/- 184 vs. 201 +/- 46%/ degrees C; P = 0.08). SR/T(in) threshold was delayed (37.06 +/- 0.11 vs. 37.34 +/- 0.06 degrees C; P < or = 0.05), but the slope of SR/T(in) (3.45 +/- 1.22 vs. 2.58 +/- 0.71 mg x min-1 x cm-2 x degrees C-1) and total sweat loss (0.42 +/- 0.06 vs. 0.44 +/- 0.08 kg) were not changed. The higher resting and exercise T(in) and delayed onset of SBF and SR suggest a centrally mediated elevation in the thermoregulatory set point during bed rest exposure.

  5. Regional and circadian variations of sweating rate and body surface temperature in camels (Camelus dromedarius).

    PubMed

    Abdoun, Khalid A; Samara, Emad M; Okab, Aly B; Al-Haidary, Ahmed A

    2012-07-01

    It was the aim of this study to investigate the regional variations in surface temperature and sweating rate and to visualize body thermal windows responsible for the dissipation of excess body heat in dromedary camels. This study was conducted on five dromedary camels with mean body weight of 450 ± 20.5 kg and 2 years of age. Sweating rate, skin and body surface temperature showed significant (P < 0.001) circadian variation together with the variation in ambient temperature. However, daily mean values of sweating rate, skin and body surface temperature measured on seven regions of the camel body did not significantly differ. The variation in body surface temperature compared to the variation in skin temperature was higher in the hump compared to the axillary and flank regions, indicating the significance of camel's fur in protecting the skin from daily variation in ambient temperature. Infrared thermography revealed that flank and axillary regions had lower thermal gradients at higher ambient temperature (T(a) ) and higher thermal gradients at lower T(a) , which might indicate the working of flank and axillary regions as thermal windows dissipating heat during the night. Sweating rate showed moderate correlation to skin and body surface temperatures, which might indicate their working as potential thermal drivers of sweating in camels. © 2012 The Authors. Animal Science Journal © 2012 Japanese Society of Animal Science.

  6. Transient Sweat Rate Calculation from Humidity Measurements Under Clothing

    DTIC Science & Technology

    2006-07-01

    Evaporation of sweat from the skin lowers core and skin temperatures, thus better enabling proper body temperatures in the heat. However, workers ...when individual workers require water to compensate for heat stress. This study made use of a sweating manikin and data from human studies to...Transient Sweat Rate Calculation from Humidity Measurements under Clothing M. Yokota, L.G. Berglund*, J.A. Gonzalez, L.A. Blanchard U.S. Army

  7. Relationships between micronutrient losses in sweat and blood pressure among heat-exposed steelworkers.

    PubMed

    Tang, Yong-Mei; Wang, Dao-Gang; Li, Jun; Li, Xing-Hua; Wang, Qian; Liu, Nan; Liu, Wei-Tian; Li, Ying-Xue

    2016-06-10

    We aimed to examine the effect of micronutrient losses through sweat on blood pressure (BP) among heat-exposed steelworkers. A total of 224 heat-exposed male steelworkers from an ironworks facility were evaluated in July 2012. We measured the Wet Bulb Globe Temperature Index to evaluate the level of heat stress in the workplace. We collected sweat from the workers during an eight-hour work, and then we measured the micronutrients in the sweat. We also measured the BP of each worker. The results revealed that vitamin C, potassium, and calcium losses in sweat were positively correlated with systolic (SBP) and diastolic (DBP) blood pressure (all P<0.05). A linear stepwise regression analysis revealed that potassium, and calcium losses in sweat adversely affected SBP and DBP (all P<0.05). An analysis of covariance showed that SBP increased when potassium or calcium losses in sweat were >900 mg, or >100 mg, respectively. Further, DBP increased when potassium or calcium losses in sweat were >600 mg or >130 mg, respectively. Therefore, vitamin C, potassium, and calcium losses in sweat may adversely effect BP. To help steelworkers maintain healthy BP, facilities with high temperatures should try to lower environmental temperatures to reduce vitamin C, potassium, and calcium losses in sweat. Additionally, heat-exposed steelworkers may need to increase their dietary intakes of vitamin C, potassium, and calcium. Further research is needed to confirm these findings and support these recommendations.

  8. Relationships between micronutrient losses in sweat and blood pressure among heat-exposed steelworkers

    PubMed Central

    TANG, Yong-Mei; WANG, Dao-Gang; LI, Jun; LI, Xing-Hua; WANG, Qian; LIU, Nan; LIU, Wei-Tian; LI, Ying-Xue

    2016-01-01

    We aimed to examine the effect of micronutrient losses through sweat on blood pressure (BP) among heat-exposed steelworkers. A total of 224 heat-exposed male steelworkers from an ironworks facility were evaluated in July 2012. We measured the Wet Bulb Globe Temperature Index to evaluate the level of heat stress in the workplace. We collected sweat from the workers during an eight-hour work, and then we measured the micronutrients in the sweat. We also measured the BP of each worker. The results revealed that vitamin C, potassium, and calcium losses in sweat were positively correlated with systolic (SBP) and diastolic (DBP) blood pressure (all P<0.05). A linear stepwise regression analysis revealed that potassium, and calcium losses in sweat adversely affected SBP and DBP (all P<0.05). An analysis of covariance showed that SBP increased when potassium or calcium losses in sweat were >900 mg, or >100 mg, respectively. Further, DBP increased when potassium or calcium losses in sweat were >600 mg or >130 mg, respectively. Therefore, vitamin C, potassium, and calcium losses in sweat may adversely effect BP. To help steelworkers maintain healthy BP, facilities with high temperatures should try to lower environmental temperatures to reduce vitamin C, potassium, and calcium losses in sweat. Additionally, heat-exposed steelworkers may need to increase their dietary intakes of vitamin C, potassium, and calcium. Further research is needed to confirm these findings and support these recommendations. PMID:27087421

  9. Mechanisms of thermal acclimation to exercise and heat

    NASA Technical Reports Server (NTRS)

    Nadel, E. R.; Pandolf, K. B.; Roberts, M. F.; Stolwijk, J. A. J.

    1974-01-01

    By plotting local sweating rate from a given area against the central sweating drive (which is analogous to esophageal temperature, when mean skin temperature is constant), it is possible to determine the characteristic gain constant of that area as well as its point of zero central drive. An increase in the gain constant as a result of acclimation would indicate an increased sensitivity of the sweating mechanism per unit of central sweating drive, i.e., enhanced peripheral sensitivity. A displacement of the point of zero central drive as a result of acclimation would indicate that central mechanisms are responsible for the heightened sweating response. The study was undertaken to provide information about whether central or peripheral physiological mechanisms provide for increased sweating capabilities during acclimation, and about whether the increased sweating capabilities in heat acclimation and physical training are provided for by the same mechanisms.

  10. Function of human eccrine sweat glands during dynamic exercise and passive heat stress

    NASA Technical Reports Server (NTRS)

    Kondo, N.; Shibasaki, M.; Aoki, K.; Koga, S.; Inoue, Y.; Crandall, C. G.

    2001-01-01

    The purpose of this study was to identify the pattern of change in the density of activated sweat glands (ASG) and sweat output per gland (SGO) during dynamic constant-workload exercise and passive heat stress. Eight male subjects (22.8 +/- 0.9 yr) exercised at a constant workload (117.5 +/- 4.8 W) and were also passively heated by lower-leg immersion into hot water of 42 degrees C under an ambient temperature of 25 degrees C and relative humidity of 50%. Esophageal temperature, mean skin temperature, sweating rate (SR), and heart rate were measured continuously during both trials. The number of ASG was determined every 4 min after the onset of sweating, whereas SGO was calculated by dividing SR by ASG. During both exercise and passive heating, SR increased abruptly during the first 8 min after onset of sweating, followed by a slower increase. Similarly for both protocols, the number of ASG increased rapidly during the first 8 min after the onset of sweating and then ceased to increase further (P > 0.05). Conversely, SGO increased linearly throughout both perturbations. Our results suggest that changes in forearm sweating rate rely on both ASG and SGO during the initial period of exercise and passive heating, whereas further increases in SR are dependent on increases in SGO.

  11. FDTD analysis of human body-core temperature elevation due to RF far-field energy prescribed in the ICNIRP guidelines.

    PubMed

    Hirata, Akimasa; Asano, Takayuki; Fujiwara, Osamu

    2007-08-21

    This study investigated the relationship between the specific absorption rate and temperature elevation in an anatomically-based model named NORMAN for exposure to radio-frequency far fields in the ICNIRP guidelines (1998 Health Phys. 74 494-522). The finite-difference time-domain method is used for analyzing the electromagnetic absorption and temperature elevation in NORMAN. In order to consider the variability of human thermoregulation, parameters for sweating are derived and incorporated into a conventional sweating formula. First, we investigated the effect of blood temperature variation modeling on body-core temperature. The computational results show that the modeling of blood temperature variation was the dominant factor influencing the body-core temperature. This is because the temperature in the inner tissues is elevated via the circulation of blood whose temperature was elevated due to EM absorption. Even at different frequencies, the body-core temperature elevation at an identical whole-body average specific absorption rate (SAR) was almost the same, suggesting the effectiveness of the whole-body average SAR as a measure in the ICNIRP guidelines. Next, we discussed the effect of sweating on the temperature elevation and thermal time constant of blood. The variability of temperature elevation caused by the sweating rate was found to be 30%. The blood temperature elevation at the basic restriction in the ICNIRP guidelines of 0.4 W kg(-1) is 0.25 degrees C even for a low sweating rate. The thermal time constant of blood temperature elevation was 23 min and 52 min for a man with a lower and a higher sweating rate, respectively, which is longer than the average time of the SAR in the ICNIRP guidelines. Thus, the whole-body average SAR required for blood temperature elevation of 1 degrees C was 4.5 W kg(-1) in the model of a human with the lower sweating coefficients for 60 min exposure. From a comparison of this value with the basic restriction in the ICNIRP guidelines of 0.4 W kg(-1), the safety factor was 11.

  12. The effect of water temperature and voluntary drinking on the post rehydration sweating.

    PubMed

    Hosseinlou, Abdollah; Khamnei, Saeed; Zamanlu, Masumeh

    2013-01-01

    During heat stress and dehydration, thermoregulation is partly suppressed to save body fluid and circulation. Drinking induces the recovery of thermoregulatory responses including sweating. Our objective is to investigate the effect of water temperature and voluntary drinking on the extent of the drinking-induced sweating. Six healthy subjects 23.7 ± 0.6 yr old and 80.7 ± 5.7 kg wt were dehydrated by performing mild exercise (ergometer cycling) in a hot and humid chamber (38-40°C, 20-28% relative humidity). After dehydration, subjects were allowed to drink water with temperatures of 5, 16, 26, 58°C on four separate days. The sweating rate was measured on the forehead area before and after drinking. Also, blood samples were collected during the experiments and plasma osmolality was measured. Sweating increased markedly just a few minutes after the onset of drinking. The rate of this response was lower in ingested water temperature of 5°C (0.43 ± 0.03 g, p = 0.000). Different intake occurred with different water temperatures (respectively 4.2, 6.4, 3.1, 1.8 ml/kg). Water at 16°C induced higher intake (6.4 ml/kg) together with lower sweating (0.54 ± 0.03 g), which can result in optimum level of hydration. Conclusion- When dehydrated subjects drink water with different temperatures, there are different sweating responses together with different voluntary intakes. According to our results, consuming 16°C water, cool tap water, could be suggested in dehydration.

  13. Wearable sweat detector device design for health monitoring and clinical diagnosis

    NASA Astrophysics Data System (ADS)

    Wu, Qiuchen; Zhang, Xiaodong; Tian, Bihao; Zhang, Hongyan; Yu, Yang; Wang, Ming

    2017-06-01

    Miniaturized sensor is necessary part for wearable detector for biomedical applications. Wearable detector device is indispensable for online health care. This paper presents a concept of an wearable digital health monitoring device design for sweat analysis. The flexible sensor is developed to quantify the amount of hydrogen ions in sweat and skin temperature in real time. The detection system includes pH sensor, temperature sensor, signal processing module, power source, microprocessor, display module and so on. The sweat monitoring device is designed for sport monitoring or clinical diagnosis.

  14. Why Do I Sweat So Much?

    MedlinePlus

    ... Health Food & Fitness Diseases & Conditions Infections Drugs & Alcohol School & ... perfectly normal to sweat. Sweating plays an important health role because it helps maintain body temperature by cooling us down. When we're hot ...

  15. The relative influence of temperature and humidity on cutaneous function in Bos indicus and Bos taurus females

    NASA Astrophysics Data System (ADS)

    Egbunike, G. N.; Ogunmola, A. L.; Amakiri, S. F.

    1983-09-01

    The relative importance of dry- and wet-bulb temperatures on cutaneous function in Bos indicus and Bos taurus females under humid tropical climatic conditions was evaluated. The parameters investigated were sweating rate and skin temperature, while the species utilised were zebu White Fulani ( Bos indicus) and German Brown and German Black and White ( Bos taurus). The sweating rate, irrespective of breed, differed with the site of sampling and was more influenced by dry-bulb (59%) than by wet-bulb temperature (41%). Skin temperature responded more to wet-bulb temperature in White Fulani and German Black and White cattle, but not in German Brown cattle. It is concluded that the response of the animals, with respect to sweating, was similar but that the efficiency of sweating, judged by the lowering of skin temperature, was higher in Bos indicus than in Bos taurus. This, in part, may explain the higher degree of comfort demonstrated by Bos indicus under tropical conditions.

  16. Effect of local acetylcholinesterase inhibition on sweat rate in humans

    NASA Technical Reports Server (NTRS)

    Shibasaki, M.; Crandall, C. G.

    2001-01-01

    ACh is the neurotransmitter responsible for increasing sweat rate (SR) in humans. Because ACh is rapidly hydrolyzed by acetylcholinesterase (AChE), it is possible that AChE contributes to the modulation of SR. Thus the primary purpose of this project was to identify whether AChE around human sweat glands is capable of modulating SR during local application of various concentrations of ACh in vivo, as well as during a heat stress. In seven subjects, two microdialysis probes were placed in the intradermal space of the forearm. One probe was perfused with the AChE inhibitor neostigmine (10 microM); the adjacent membrane was perfused with the vehicle (Ringer solution). SR over both membranes was monitored via capacitance hygrometry during microdialysis administration of various concentrations of ACh (1 x 10(-7)-2 M) and during whole body heating. SR was significantly greater at the neostigmine-treated site than at the control site during administration of lower concentrations of ACh (1 x 10(-7)-1 x 10(-3) M, P < 0.05), but not during administration of higher concentrations of ACh (1 x 10(-2)-2 M, P > 0.05). Moreover, the core temperature threshold for the onset of sweating at the neostigmine-treated site was significantly reduced relative to that at the control site. However, no differences in SR were observed between sites after 35 min of whole body heating. These results suggest that AChE is capable of modulating SR when ACh concentrations are low to moderate (i.e., when sudomotor activity is low) but is less effective in governing SR after SR has increased substantially.

  17. A dose-response evaluation of rumen-protected niacin in thermoneutral or heat-stressed lactating Holstein cows.

    PubMed

    Rungruang, S; Collier, J L; Rhoads, R P; Baumgard, L H; de Veth, M J; Collier, R J

    2014-01-01

    Twenty-four multiparous high-producing dairy cows (40.0±1.4kg/d) were used in a factorial design to evaluate effects of 2 environments [thermoneutral (TN) and heat stress (HS)] and a dose range of dietary rumen-protected niacin (RPN; 0, 4, 8, or 12g/d) on body temperature, sweating rate, feed intake, water intake, production parameters, and blood niacin concentrations. Temperature-humidity index values during TN never exceeded 68 (stress threshold), whereas temperature-humidity index values during HS were above 68 for 24h/d. The HS environment increased hair coat and skin, rectal, and vaginal temperatures; respiration rate; skin and hair coat evaporative heat loss; and water intake and decreased DMI (3.5kg/d), milk yield (4.1kg/d), 4% fat-corrected milk (2.7kg/d), and milk protein yield (181.7g/d). Sweating rate increased during HS (12.7g/m(2) per h) compared with TN, but this increase was only 10% of that reported in summer-acclimated cattle. Niacin supplementation did not affect sweating rate, dry-matter intake, or milk yield in either environment. Rumen-protected niacin increased plasma and milk niacin concentrations in a linear manner. Heat stress reduced niacin concentration in whole blood (7.86 vs. 6.89μg/mL) but not in milk. Reduced blood niacin concentration was partially corrected by dietary RPN. An interaction existed between dietary RPN and environment; dietary RPN linearly increased water intake in both environments, but the increase was greater during HS conditions. Increasing dietary RPN did not influence skin temperatures. During TN, supplementing 12g/d of RPN increased hair coat (unshaved skin; 30.3 vs. 31.3°C at 1600h) but not shaved skin (32.8 vs. 32.9°C at 1600h) temperature when compared with 0g/d at all time points, whereas the maximum temperature (18°C) of the room was lower than skin temperature. These data suggest that dietary RPN increased water intake during both TN and HS and hair coat temperature during TN; however, core body temperature was unaffected. Thus, encapsulated niacin did not improve thermotolerance of winter-acclimated lactating dairy cows exposed to moderate thermal stress in Arizona. Copyright © 2014 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  18. Studies on physiological responses of residents in Okinawa to a hot environment.

    PubMed

    Hori, S; Ihzuka, H; Nakamura, M

    1976-01-01

    In an attempt to reconfirm Kuno's observation that changes in sweating reaction during long-term heat acclimatization differ from those during short-term heat acclimatization, Ohara's sweating test was performed in summer in Okinawa on 37 male subjects, including 19 residents born and raised in Okinawa (group O) and 18 residents born and raised on one of the main Japanese islands (group M). Seasonal variation of adaptability to heat was also studied in some subjects of both groups. Group O showed significantly less sweat loss, lower Na concentration in sweat and a longer latent period for onset of sweating than group M. Group O showed no seasonal variation in sweat loss, while group M showed considerably greater sweat loss in summer than in winter. In both groups, lower Na concentration in sweat, lower rise in rectal temperature and lesser increase in heart rate in summer than in winter were observed. Seasonal difference in physiological responses of group O to heat exposure was less than that of group M. In conclusion, it was assumed that acclimatization to heat of group O had advanced further than that of group M and this was the reason for longer latent period of sweating and lesser sweat loss in group O in spite of the same rise in rectal temperature in both groups. Discussions were carried out to explain how the sweating pattern and mechanism of acclimatization in group O were different from those in group M.

  19. Sweating responses during heat acclimation and moderate conditioning

    NASA Technical Reports Server (NTRS)

    Shvartz, E.; Bhattacharya, A.; Sperinde, S. J.; Brock, P. J.; Sciaraffa, D.; Van Beaumont, W.

    1979-01-01

    Experiments were conducted on ten young male subjects to determine sweating onset, distribution, and patterns as well as the relationships of these responses to body temperature during heat acclimation and moderate conditioning performed in temperate (24 C) conditions. The subjects are randomly assigned to two groups of five subjects each. The experimental period consisted of eight successive days of either graded exercise to exhaustion on a bicycle ergometer in heat (acclimation group) or in a temperate environment (control group). Major conclusions are that (1) acclimation and conditioning result in relatively more sweat rate on the limbs than on the torso, but that these changes are less related to body temperature than torso sweat rate; and (2) sweating sensitivity increases during acclimation and conditioning, but its contribution to heat acclimation is minor.

  20. Temperature Regulation in Crewmembers After a 115-Day Space Flight

    NASA Technical Reports Server (NTRS)

    Lee, S. M. C.; Williams, W. J.; Siconolfi, S. F.; Gonzalez, R.; Greenleaf, J. E.; Mikhavlov, V.; Kobzev, Y.; Fortney, S. M.

    1996-01-01

    Impaired thermoregulation, which has been observed during exercise following bed rest, may significantly impact crewmembers during space flight operations by decreasing exercise capacity and orthostatic tolerance. Impaired temperature regulation would cause higher levels of core temperature, due to an attenuated cutaneous vasodilatory reflex and sweating response, for a given oxygen consumption. Two mate crewmembers of the Mir 18 mission performed supine cycle exercise se (20 min @ 40% and 20 min @ 65% preflight VO2pk) 145 days preflight and 5 days postflight. Core temperature (Tcore) was measured by an ingestible telemetry pill, skin blood flow (SBF) by laser Doppler velocimetry, and sweat rate (SR) by dew point hygrometry. Tcore at the time of test termination was similar (37.8 C) for both subjects before and after flight despite a shorter test duration (40 vs 28-29 minutes) postflight. The slopes of the SBF/Tcore relationship (Subj 1: 396 vs 214; Subj 2: 704 vs 143 Perfusion Unit/degC) and SR/Tcore relationship (Subj 1: 4.5 vs 2.1; Subj 2: 11.0 vs 3.6mg/min/sq cm/degC) were reduced postflight. Tcore thresholds for both SR (Subj 1: 37.4 vs 37.6; Subj 2: 37.6 vs 37.6 C) and SBF (Subj 1: 37.3 vs 37.5; Subj 2: 37.6 vs 37.7 C) were similar pre- to postflight. For these 2 crewmembers, it appeared that thermoregulation during exercise was impaired as evidenced by compromised heat loss responses after long-duration space flight.

  1. Effect of antiperspirants on whole body sweat rate and thermoregulation.

    PubMed

    Burry, J S; Evans, R L; Rawlings, A V; Shiu, J

    2003-08-01

    It is well established that the evaporation of sweat from the human body surface is the main mechanism by which heat balance is maintained following a rise in body core temperature. Since the introduction of the first brand name antiperspirant in the United States during the early 1900s, antiperspirant products designed to control underarm wetness have grown to represent one of the largest cosmetic categories in most global markets. However, although axillary sweating only constitutes less than 1% of whole body sweat rate, consumers, particularly in hot countries, have begun to articulate the concern that antiperspirants may interfere with the body's natural cooling process. To investigate this, we undertook carefully designed experiments that measured the effects of axillary antiperspirant application on whole body sweat rate and body core temperature, following a regimen of exercise-induced heat stress in a hot environment in human volunteers. Our data show clearly that although antiperspirant prevents sweat production in the axillary area, this does not impact the ability of the body to thermoregulate following a rise in body core temperature. Thus, recent consumer questioning over this aspect of antiperspirant use appears to be unwarranted.

  2. Interindividual variability in sweat electrolyte concentration in marathoners.

    PubMed

    Lara, Beatriz; Gallo-Salazar, César; Puente, Carlos; Areces, Francisco; Salinero, Juan José; Del Coso, Juan

    2016-01-01

    Sodium (Na(+)) intake during exercise aims to replace the Na(+) lost by sweat to avoid electrolyte imbalances, especially in endurance disciplines. However, Na(+) needs can be very different among individuals because of the great inter-individual variability in sweat electrolyte concentration. The aim of this investigation was to determine sweat electrolyte concentration in a large group of marathoners. A total of 157 experienced runners (141 men and 16 women) completed a marathon race (24.4 ± 3.6 °C and 27.7 ± 4.8 % of humidity). During the race, sweat samples were collected by using sweat patches placed on the runners' forearms. Sweat electrolyte concentration was measured by using photoelectric flame photometry. As a group, sweat Na(+) concentration was 42.9 ± 18.7 mmol·L(-1) (minimal-maximal value = 7.0-95.5 mmol·L(-1)), sweat Cl(-) concentration was 32.2 ± 15.6 mmol·L(-1) (7.3-90.6 mmol·L(-1)) and sweat K(+) concentration was 6.0 ± 0.9 mmol·L(-1) (3.1-8.0 mmol·L(-1)). Women presented lower sweat Na(+) (33.9 ± 12.1 vs 44.0 ± 19.1 mmol·L(-1); P = 0.04) and sweat Cl(-) concentrations (22.9 ± 10.5 vs 33.2 ± 15.8 mmol·L(-1); P = 0.01) than men. A 20 % of individuals presented a sweat Na(+) concentration higher than 60 mmol·L(-1) while this threshold was not surpassed by any female marathoner. Sweat electrolyte concentration did not correlate to sweat rate, age, body characteristics, experience or training. Although there was a significant correlation between sweat Na(+) concentration and running pace (r = 0.18; P = 0.03), this association was weak to interpret that sweat Na(+) concentration increased with running pace. The inter-individual variability in sweat electrolyte concentration was not explained by any individual characteristics except for individual running pace and sex. An important portion (20 %) of marathoners might need special sodium intake recommendations due to their high sweat salt losses.

  3. Wearable/disposable sweat-based glucose monitoring device with multistage transdermal drug delivery module

    PubMed Central

    Lee, Hyunjae; Song, Changyeong; Hong, Yong Seok; Kim, Min Sung; Cho, Hye Rim; Kang, Taegyu; Shin, Kwangsoo; Choi, Seung Hong; Hyeon, Taeghwan; Kim, Dae-Hyeong

    2017-01-01

    Electrochemical analysis of sweat using soft bioelectronics on human skin provides a new route for noninvasive glucose monitoring without painful blood collection. However, sweat-based glucose sensing still faces many challenges, such as difficulty in sweat collection, activity variation of glucose oxidase due to lactic acid secretion and ambient temperature changes, and delamination of the enzyme when exposed to mechanical friction and skin deformation. Precise point-of-care therapy in response to the measured glucose levels is still very challenging. We present a wearable/disposable sweat-based glucose monitoring device integrated with a feedback transdermal drug delivery module. Careful multilayer patch design and miniaturization of sensors increase the efficiency of the sweat collection and sensing process. Multimodal glucose sensing, as well as its real-time correction based on pH, temperature, and humidity measurements, maximizes the accuracy of the sensing. The minimal layout design of the same sensors also enables a strip-type disposable device. Drugs for the feedback transdermal therapy are loaded on two different temperature-responsive phase change nanoparticles. These nanoparticles are embedded in hyaluronic acid hydrogel microneedles, which are additionally coated with phase change materials. This enables multistage, spatially patterned, and precisely controlled drug release in response to the patient’s glucose level. The system provides a novel closed-loop solution for the noninvasive sweat-based management of diabetes mellitus. PMID:28345030

  4. Observation of the sweating in lipstick by scanning electron microscopy.

    PubMed

    Seo, S Y; Lee, I S; Shin, H Y; Choi, K Y; Kang, S H; Ahn, H J

    1999-06-01

    The relationship between the wax matrix in lipstick and sweating has been investigated by observing the change of size and shape of the wax matrix due to sweating by Scanning Electron Microscopy (SEM). For observation by SEM, a lipstick sample was frozen in liquid nitrogen. The oil in the lipstick was then extracted in cold isopropanol (-70 degrees C) for 1-3 days. After the isopropanol was evaporated, the sample was sputtered with gold and examined by SEM. The change of wax matrix underneath the surface from fine, uniform structure to coarse, nonuniform structure resulted from the caking of surrounding wax matrix. The oil underneath the surface migrated to the surface of lipstick with sweating; consequently the wax matrix in that region was rearranged into the coarse matrix. In case of flamed lipstick, sweating was delayed and the wax matrix was much coarser than that of the unflamed one. The larger wax matrix at the surface region was good for including oil. The effect of molding temperature on sweating was also studied. As the molding temperature rose, sweating was greatly reduced and the size of the wax matrix increased. It was found that sweating was influenced by the compatibility of wax and oil. A formula consisting of wax and oil that have good compatibility has a tendency to reduce sweating and increase the size of the wax matrix. When pigments were added to wax and oil, the size of the wax matrix was changed, but in all cases sweating was increased due to the weakening of the binding force between wax and oil. On observing the thick membrane of wax at the surface of lipstick a month after molding it was also found that sweating was influenced by ageing. In conclusion, the structure of the wax matrix at the surface region of lipstick was changed with the process of flaming, molding temperature, compatibility of wax and oil, addition of pigment, and ageing. In most cases, as the size of the wax matrix was increased, sweating was reduced and delayed.

  5. System properties, feedback control and effector coordination of human temperature regulation.

    PubMed

    Werner, Jürgen

    2010-05-01

    The aim of human temperature regulation is to protect body processes by establishing a relative constancy of deep body temperature (regulated variable), in spite of external and internal influences on it. This is basically achieved by a distributed multi-sensor, multi-processor, multi-effector proportional feedback control system. The paper explains why proportional control implies inherent deviations of the regulated variable from the value in the thermoneutral zone. The concept of feedback of the thermal state of the body, conveniently represented by a high-weighted core temperature (T (c)) and low-weighted peripheral temperatures (T (s)) is equivalent to the control concept of "auxiliary feedback control", using a main (regulated) variable (T (c)), supported by an auxiliary variable (T (s)). This concept implies neither regulation of T (s) nor feedforward control. Steady-states result in the closed control-loop, when the open-loop properties of the (heat transfer) process are compatible with those of the thermoregulatory processors. They are called operating points or balance points and are achieved due to the inherent property of dynamical stability of the thermoregulatory feedback loop. No set-point and no comparison of signals (e.g. actual-set value) are necessary. Metabolic heat production and sweat production, though receiving the same information about the thermal state of the body, are independent effectors with different thresholds and gains. Coordination between one of these effectors and the vasomotor effector is achieved by the fact that changes in the (heat transfer) process evoked by vasomotor control are taken into account by the metabolic/sweat processor.

  6. Control of skin blood flow, sweating, and heart rate - Role of skin vs. core temperature

    NASA Technical Reports Server (NTRS)

    Wyss, C. R.; Brengelmann, G. L.; Johnson, J. M.; Rowell, L. B.; Niederberger, M.

    1974-01-01

    A study was conducted to generate quantitative expressions for the influence of core temperature, skin temperature, and the rate of change of skin temperature on sweat rate, skin blood flow, and heart rate. A second goal of the study was to determine whether the use of esophageal temperature rather than the right atrial temperature as a measure of core temperature would lead to different conclusions about the control of measured effector variables.

  7. Sweating is greater in NCAA football linemen independently of heat production.

    PubMed

    Deren, Tomasz M; Coris, Eric E; Bain, Anthony R; Walz, Steve M; Jay, Ollie

    2012-02-01

    The study's purpose was to investigate whether differences in local sweat rates on the upper body between American football linemen (L) and backs (B) exist independently of differences in metabolic heat production. Twelve NCAA Division I American football players (6 linemen (mass = 141.6 ± 6.5 kg, body surface area (BSA) = 2.67 ± 0.08 m2) and 6 backs (mass = 88.1 ± 13.4 kg, BSA = 2.11 ± 0.19 m2)) cycled at a fixed metabolic heat production per unit BSA of 350 W·m(-2) for 60 min in a climatic chamber (t(db) [dry bulb temperature] = 32.4°C ± 1.0°C, t(wb) [wet bulb temperature] = 26.3°C ± 0.6°C, v [air velocity] = 0.9 ± 0.1 m·s(-1)). Local sweat rates on the head, arm, shoulder, lower back, and chest were measured after 10, 30, and 50 min of exercise. Core temperature, mean skin temperature, and HR were measured throughout exercise. Because metabolic heat production per unit surface area was fixed between participants, the rate of evaporation required for heat balance was similar (L = 261 ± 35 W·m(-2), B = 294 ± 30 W·m(-2), P = 0.11). However, local sweat rates on the head, arm, shoulder, and chest were all significantly greater (P < 0.05) in linemen at all time points, and end-exercise core temperature was significantly greater (P = 0.033) in linemen (38.5°C ± 0.4°C) relative to backs (38.0°C ± 0.2°C) despite a ∼25% lower heat production per unit mass. The change in mean skin temperature from rest was greater in linemen (P < 0.001) after 15, 30, 45, and 60 min, and HR was greater in linemen for the last 30 min of exercise. Football linemen sweat significantly more on the torso and head than football backs independently of any differences in metabolic heat production per unit BSA and therefore the evaporative requirements for heat balance. Despite greater sweating, linemen demonstrated significantly greater elevations in core temperature suggesting that sweating efficiency (i.e., the proportion of sweat that evaporates) was much lower in linemen.

  8. Physiological adjustments of young men to five-hour desert walks.

    PubMed

    Dill, D B; Soholt, L F; Oddershede, I B

    1976-02-01

    Seven young men undertook a desert walk of 30 km at a rate of 100 m/min. Six finished; the seventh stopped after 24 km. Each satisfied his thirst with cool tap water each hour. Periodic observations included metabolic rate, blood pressure, heart rate, rectal and skin temperature, body weight, and volume of water drunk. Hand sweat was collected each hour and body sweat residues on the skin were collected at the end of the walk. Subjective reports revealed portents of breakdown: aching muscles, painful joints, hot or blistered feet, hunger, and boredom. Cardiovascular adjustment and temperature regulation maintained tolerable conditions. The volumes of water evaporated by the 5-h walkers were about the same. Wet bulb temperatures were below 25 degrees C; all sweat evaporated and was available for temperature regulation. The volume of water drawn from body reserves was closely correlated with concentration of chloride in body sweat; the volume of water that satisfied thirst maintained osmotic pressure.

  9. Effect of skin wettedness on sweat gland response

    NASA Technical Reports Server (NTRS)

    Nadel, E. R.; Stolwijk, J. A. J.

    1973-01-01

    Investigation of the effect of skin wettedness upon sweating rate. Several techniques were used to gain a better understanding of the quantitative nature of this effect. The results include the finding that the evaporative power of the environment has a profound effect on the relationship between body temperature and sweating rate.

  10. The analysis of metabolites in human sweat: analytical methods and potential application to investigation of pressure ischaemia of soft tissues.

    PubMed

    Taylor, R P; Polliack, A A; Bader, D L

    1994-01-01

    A straightforward technique was developed for sweat collection applicable to tissues subjected to external load without introducing distortion of underlying tissues, and for analysis of six metabolites in the collected sweat. Chloride was measured colorimetrically and lactate, urea and urate by enzymatic methods on a centrifugal analyser. Sodium and potassium were measured by flame photometry. The methods showed good precision, recovery and linearity. To assess the technique sweat was collected: (i) from the sacrum, ischium, forearm and calf in healthy individuals at 32 degrees C for 1 h; (ii) from the sacrum of healthy subjects at ambient temperature for 9 h; (iii) at ambient temperature from the sacrum of a patient with a history of pressure sores. Sweat rates were greater at the sacrum and ischium than the calf or forearm. There were differences in the concentrations of lactate and urea between sites but these were smaller when expressed as amount secreted. Sweat rates were significantly lower in groups (ii) and (iii), but sweat could be collected reliably. This technique has potential clinical application to the investigation of susceptibility to pressure sores.

  11. A liquid cooled garment temperature controller based on sweat rate

    NASA Technical Reports Server (NTRS)

    Chambers, A. B.; Blackaby, J. R.

    1972-01-01

    An automatic controller for liquid cooled space suits is reported that utilizes human sweat rate as the primary input signal. The controller is so designed that the coolant inlet temperature is inversely proportional to the subject's latent heat loss as evidenced by evaporative water loss.

  12. The sweating foot: local differences in sweat secretion during exercise-induced hyperthermia.

    PubMed

    Taylor, Nigel A S; Caldwell, Joanne N; Mekjavic, Igor B

    2006-10-01

    Little is known regarding local differences in foot sweat secretion. Since such information is important to our understanding of sweat gland control for thermoregulatory modeling and for the design of footwear we explored this topic. Local sweat rates were investigated across core temperatures from 37-39 degrees C, achieved using endogenous (cycling) and exogenous heat (water-perfusion garment: 46 degrees C). Six healthy adults (three men, three women) performed one-legged, incremental cycling in a heated, climate-controlled chamber (36 degrees C, 60% relative humidity). Sweat rates were measured at the forehead and stationary (left) foot (capsules 3.16 cm2): three dorsal sites (base of toes, second metatarsal, and mid point), the lateral, and the central plantar surfaces. Terminal core temperatures ranged between 38.3-39.1 oC, with peak heart rates of 155-187 bpm. Most foot sweat rates were < 50% of that observed at the forehead: dorsal 1 (38%); dorsal 2 (54%); dorsal 3 (37%); lateral (24%); and plantar surfaces (18%). When averaged across the trial, local sweat rates were: 2.61 (forehead); 0.98 (dorsal 1); 1.39 (dorsal 2); 0.95 (dorsal 3); 0.62 (lateral); and 0.47 mg cm2 2 min-1 (plantar). Two key observations emerged. First, sweat secretion from the experimental foot averaged 30 ml x h(-1), peaking in the last 5 min at 50 ml x h(-1). Second, approximately 70% of the measured sweat flow emanated from the upper skin surfaces, with only 30% coming from the plantar surface.

  13. Skin temperature, thermal comfort, sweating, clothing and activity of men sledging in Antarctica

    PubMed Central

    Budd, G. M.

    1966-01-01

    1. Three men were studied while dog-sledging 320 km in 12 days in Antarctica. Conventional Antarctic clothing (`sweaters and windproofs') was worn. Four hundred observations were made of medial thigh skin temperature, thermal comfort, sweating, clothing, activity and environmental conditions. 2. Work occupied an average of 11·0 hr/day and sleep 7·5 hr. Estimated daily energy expenditure averaged 5100 kcal (range 2740-6660 kcal). 3. Skin temperature fell on exposure to cold despite the clothing worn, but was not changed by the level of activity. Sweating, and thermal comfort, were directly related to both skin temperature and activity. 4. Inside the tent, the modal value of skin temperature was 33° C (range 27-36° C) and the men were comfortable in 94% of observations. 5. During the 9·2 hr/day spent outdoors the modal value of skin temperature was 27° C (range 18-33° C) and the men felt too cold (but did not shiver) in 11% (range 7-20%) of observations, suggesting that cold stress was not negligible. However, they also felt too hot in 20% of observations and were sweating in 23%. PMID:5914254

  14. Consistency between Sweat Rate and Wet Bulb Globe Temperature for the Assessment of Heat Stress of People Working Outdoor in Arid and Semi-arid Regions.

    PubMed

    Heidari, Hamidreza; Golbabaei, Farideh; Shamsipour, Aliakbar; Rahimi Forushani, Abbas; Gaeini, Abbasali

    2018-01-01

    Heat stress is common among workers in arid and semi-arid areas. In order to take every preventive measure to protect exposed workers against heat-related disorders, it is crucial to choose an appropriate index that accurately relates environmental parameters to physiological responses. To investigate the consistency between 2 heat stress and strain indices, ie , sweat rate and wet bulb globe temperature (WBGT), for the assessment of heat stress of people working outdoor in arid and semi-arid regions in Iran. During spring and summer, 136 randomly selected outdoor workers were enrolled in this study. Using a defined protocol, the sweat rate of these workers was measured 3 times a day. Simultaneously, the environmental parameters including WBGT index were recorded for each working station. The level of agreement between sweat rate and WBGT was poor ( κ <0.2). Based on sweat rate, no case exceeding the reference value was observed during the study. WBGT overestimated the heat stress in outdoor workers compared to sweat rate. It seems that the sweat rate standards may need some modifications related to real condition of work in arid and semi-arid regions in Iran. Moreover, it seems that judging workers solely based on monitoring their sweat rate in such regions, can probably result in underestimation of heat stress.

  15. Working Up a Good Sweat – The Challenges of Standardising Sweat Collection for Metabolomics Analysis

    PubMed Central

    Hussain, Joy N; Mantri, Nitin; Cohen, Marc M

    2017-01-01

    Introduction Human sweat is a complex biofluid of interest to diverse scientific fields. Metabolomics analysis of sweat promises to improve screening, diagnosis and self-monitoring of numerous conditions through new applications and greater personalisation of medical interventions. Before these applications can be fully developed, existing methods for the collection, handling, processing and storage of human sweat need to be revised. This review presents a cross-disciplinary overview of the origins, composition, physical characteristics and functional roles of human sweat, and explores the factors involved in standardising sweat collection for metabolomics analysis. Methods A literature review of human sweat analysis over the past 10 years (2006–2016) was performed to identify studies with metabolomics or similarly applicable ‘omics’ analysis. These studies were reviewed with attention to sweat induction and sampling techniques, timing of sweat collection, sweat storage conditions, laboratory derivation, processing and analytical platforms. Results Comparative analysis of 20 studies revealed numerous factors that can significantly impact the validity, reliability and reproducibility of sweat analysis including: anatomical site of sweat sampling, skin integrity and preparation; temperature and humidity at the sweat collection sites; timing and nature of sweat collection; metabolic quenching; transport and storage; qualitative and quantitative measurements of the skin microbiota at sweat collection sites; and individual variables such as diet, emotional state, metabolic conditions, pharmaceutical, recreational drug and supplement use. Conclusion Further development of standard operating protocols for human sweat collection can open the way for sweat metabolomics to significantly add to our understanding of human physiology in health and disease. PMID:28798503

  16. [Study on sweat gland regeneration induced by microenvironment of three-dimensional bioprinting].

    PubMed

    Yao, B; Xie, J F; Huang, S; Fu, X B

    2017-01-20

    Sweat glands are abundant in the body surface and essential for thermoregulation. Sweat glands fail to conduct self-repair in patients with large area of burn and trauma, and the body temperature of patients increases in hot climate, which may cause shock or even death. Now, co-culture system, reprogramming, and tissue engineering have made progresses in inducing sweat gland regeneration, but the inductive efficiency and duration need to be improved. Cellular microenvironment can regulate cell biological behavior, including cell migration and cell differentiation. This article reviews the studies of establishment of microenvironment in vitro by three-dimensional bioprinting technology to induce sweat gland regeneration.

  17. Real-time sweat analysis via alternating current conductivity of artificial and human sweat

    NASA Astrophysics Data System (ADS)

    Liu, Gengchen; Alomari, Mahmoud; Sahin, Bunyamin; Snelgrove, Samuel E.; Edwards, Jeffrey; Mellinger, Axel; Kaya, Tolga

    2015-03-01

    Dehydration is one of the most profound physiological challenges that significantly affects athletes and soldiers if not detected early. Recently, a few groups have focused on dehydration detection using sweat as the main biomarker. Although there are some proposed devices, the electrical and chemical characteristics of sweat have yet to be incorporated into the validations. In this work, we have developed a simple test setup to analyze artificial sweat that is comprised the main components of human sweat. We provide theoretical and experimental details on the electrical and chemical behavior of the artificial sweat for various concentration values within a temperature range of 5 °C to 50 °C. We have also developed an efficient sweat collecting and detection system based on 3D printing. Human studies were conducted and this particular protocol has shown that dehydration starts to take effect as early as 40 min into the physical activity if there is no fluid intake during the exercise. We believe that our device will lead to developing viable real-time sweat analysis systems.

  18. How to avoid overheating during exercise

    MedlinePlus

    ... is always working to maintain a safe temperature. Sweating helps your body cool down. When you exercise ... your muscles. This increases your heart rate. You sweat a lot, losing fluids in your body. If ...

  19. 3D modeling and characterization of a calorimetric flow rate sensor for sweat rate sensing applications

    NASA Astrophysics Data System (ADS)

    Iftekhar, Ahmed Tashfin; Ho, Jenny Che-Ting; Mellinger, Axel; Kaya, Tolga

    2017-03-01

    Sweat-based physiological monitoring has been intensively explored in the last decade with the hopes of developing real-time hydration monitoring devices. Although the content of sweat (electrolytes, lactate, urea, etc.) provides significant information about the physiology, it is also very important to know the rate of sweat at the time of sweat content measurements because the sweat rate is known to alter the concentrations of sweat compounds. We developed a calorimetric based flow rate sensor using PolydimethylSiloxane that is suitable for sweat rate applications. Our simple approach on using temperature-based flow rate detection can easily be adapted to multiple sweat collection and analysis devices. Moreover, we have developed a 3D finite element analysis model of the device using COMSOL Multiphysics™ and verified the flow rate measurements. The experiment investigated flow rate values from 0.3 μl/min up to 2.1 ml/min, which covers the human sweat rate range (0.5 μl/min-10 μl/min). The 3D model simulations and analytical model calculations covered an even wider range in order to understand the main physical mechanisms of the device. With a verified 3D model, different environmental heat conditions could be further studied to shed light on the physiology of the sweat rate.

  20. Wearable, Flexible, and Multifunctional Healthcare Device with an ISFET Chemical Sensor for Simultaneous Sweat pH and Skin Temperature Monitoring.

    PubMed

    Nakata, Shogo; Arie, Takayuki; Akita, Seiji; Takei, Kuniharu

    2017-03-24

    Real-time daily healthcare monitoring may increase the chances of predicting and diagnosing diseases in their early stages which, currently, occurs most frequently during medical check-ups. Next-generation noninvasive healthcare devices, such as flexible multifunctional sensor sheets designed to be worn on skin, are considered to be highly suitable candidates for continuous real-time health monitoring. For healthcare applications, acquiring data on the chemical state of the body, alongside physical characteristics such as body temperature and activity, are extremely important for predicting and identifying potential health conditions. To record these data, in this study, we developed a wearable, flexible sweat chemical sensor sheet for pH measurement, consisting of an ion-sensitive field-effect transistor (ISFET) integrated with a flexible temperature sensor: we intend to use this device as the foundation of a fully integrated, wearable healthcare patch in the future. After characterizing the performance, mechanical flexibility, and stability of the sensor, real-time measurements of sweat pH and skin temperature are successfully conducted through skin contact. This flexible integrated device has the potential to be developed into a chemical sensor for sweat for applications in healthcare and sports.

  1. In vivo single human sweat gland activity monitoring using coherent anti-Stokes Raman scattering and two-photon excited autofluorescence microscopy.

    PubMed

    Chen, X; Gasecka, P; Formanek, F; Galey, J-B; Rigneault, H

    2016-04-01

    Eccrine sweat secretion is of central importance for control of body temperature. Although the incidence of sweat gland dysfunction might appear of minor importance, it can be a real concern for people with either hypohidrosis or hyperhidrosis. However, sweat gland function remains relatively poorly explored. To investigate the function of single human sweat glands. We describe a new approach for noninvasive imaging of single sweat gland activity in human palms in vivo up to a depth of 100 μm, based on nonlinear two-photon excited autofluorescence (TPEF) and coherent anti-Stokes Raman scattering (CARS). These techniques appear to be useful compared with approaches already described for imaging single sweat gland activity, as they allow better three-dimensional spatial resolution of sweat pore inner morphology and real-time monitoring of individual sweat events. By filling the sweat pore with oil and tuning the CARS contrast at 2845 cm(-1) , we imaged the ejection of sweat droplets from a single sweat gland when oil is pushed out by sweat flow. On average, sweat events lasted for about 30 s every 3 min under the conditions studied. On the other hand, about 20% of sweat glands were found inactive. TPEF and CARS were also used to study, at the single pore level, the antiperspirant action of aluminium chlorohydrate (ACH) and to reveal, for the first time in vivo, the formation of a plug at the pore entrance, in agreement with reported ACH antiperspirant mechanisms. Although data were acquired on human palms, these techniques show great promise for a better understanding of sweat secretion physiology and should be helpful to improve the efficacy of antiperspirant formulations. © 2015 British Association of Dermatologists.

  2. A study of the thermoregulatory characteristics of a liquid-cooled garment with automatic temperature control based on sweat rate: Experimental investigation and biothermal man-model development

    NASA Technical Reports Server (NTRS)

    Chambers, A. B.; Blackaby, J. R.; Miles, J. B.

    1973-01-01

    Experimental results for three subjects walking on a treadmill at exercise rates of up to 590 watts showed that thermal comfort could be maintained in a liquid cooled garment by using an automatic temperature controller based on sweat rate. The addition of head- and neck-cooling to an Apollo type liquid cooled garment increased its effectiveness and resulted in greater subjective comfort. The biothermal model of man developed in the second portion of the study utilized heat rates and exchange coefficients based on the experimental data, and included the cooling provisions of a liquid-cooled garment with automatic temperature control based on sweat rate. Simulation results were good approximations of the experimental results.

  3. [Hyperhidrosis and social anxiety disorder--the same old thing under a different cloak?].

    PubMed

    Nahaloni, Elad; Iancu, Iulian

    2014-10-01

    Hyperhidrosis is a reason for treatment by many specialists in medicine, such as dermatologists, family medicine doctors, surgeons and also psychiatrists. Hyperhidrosis causes considerable distress and disability. Despite the fact that the condition has been known for thousands of years, it is yet unclear whether excessive sweating derives from emotional" activation of the central nervous system, whether the emotional symptoms evolve due to local dysfunction of the sweat glands, or a combination of the two problems. In this article, we will present two conditions: hyperhidrosis and Social Anxiety Disorder, a mental condition with anxiety and avoidanrce in social settings that is frequently accompanied by sweating. We will discuss the similarities and differences between these disorders and the various treatments available for these conditions. Research shows that social anxiety does not explain hyperhidrosis, but that excessive sweating reduces the threshold for social anxiety. Among people with hyperhidrosis, the functional disability and the emotional problems are mediated by the social anxiety. We propose treating the symptoms of hyperhidrosis and social anxiety disorder in combination in order to achieve maximal improvement in these patients.

  4. Physiological strain of miners at hot working places in German coal mines.

    PubMed

    Kalkowsky, Bernhard; Kampmann, Bernhard

    2006-07-01

    As the percentage of shifts in hot working conditions in German Coal mines had increased to more than 50% during the last decade, a study was carried out to record the physiological strain of miners. Thirty-eight miners participated during 125 shifts. Heart rate and rectal temperature were measured continuously. Sweat losses as well as food and fluid uptake were estimated from measurements before and after shifts. During all shifts mean heart rates resulted in 102.8 min(-1), mean rectal temperature was 37.7 degrees C. Mean sweat loss per shift was 3,436 g; mean sweat rates resulted in 494 g/h. Rehydration during the shift at high climatic stress decreased to about 60% of sweat losses. In order to state the organizational frame of work at hot working places in German coal mines, the main features of regulations of work at hot working places are presented.

  5. Physiological Effects of Chemical Protective Garments During Exercise and Heat Stress.

    DTIC Science & Technology

    1998-01-01

    The present study was designed to examine the effect of protective garments , with a range of insulation and permeability characteristics, on changes...Pre- and post-experiment nude and clothed weights were measured and used to calculate sweat production (SP) and sweat loss (SL). TAP and RAIN had...environment compared to warm conditions. Sweat production was significantly increased as suits became less permeable and as the temperature increased from

  6. Skin blood flow and local temperature independently modify sweat rate during passive heat stress in humans.

    PubMed

    Wingo, Jonathan E; Low, David A; Keller, David M; Brothers, R Matthew; Shibasaki, Manabu; Crandall, Craig G

    2010-11-01

    Sweat rate (SR) is reduced in locally cooled skin, which may result from decreased temperature and/or parallel reductions in skin blood flow. The purpose of this study was to test the hypotheses that decreased skin blood flow and decreased local temperature each independently attenuate sweating. In protocols I and II, eight subjects rested supine while wearing a water-perfused suit for the control of whole body skin and internal temperatures. While 34°C water perfused the suit, four microdialysis membranes were placed in posterior forearm skin not covered by the suit to manipulate skin blood flow using vasoactive agents. Each site was instrumented for control of local temperature and measurement of local SR (capacitance hygrometry) and skin blood flow (laser-Doppler flowmetry). In protocol I, two sites received norepinephrine to reduce skin blood flow, while two sites received Ringer solution (control). All sites were maintained at 34°C. In protocol II, all sites received 28 mM sodium nitroprusside to equalize skin blood flow between sites before local cooling to 20°C (2 sites) or maintenance at 34°C (2 sites). In both protocols, individuals were then passively heated to increase core temperature ~1°C. Both decreased skin blood flow and decreased local temperature attenuated the slope of the SR to mean body temperature relationship (2.0 ± 1.2 vs. 1.0 ± 0.7 mg·cm(-2)·min(-1)·°C(-1) for the effect of decreased skin blood flow, P = 0.01; 1.2 ± 0.9 vs. 0.07 ± 0.05 mg·cm(-2)·min(-1)·°C(-1) for the effect of decreased local temperature, P = 0.02). Furthermore, local cooling delayed the onset of sweating (mean body temperature of 37.5 ± 0.4 vs. 37.6 ± 0.4°C, P = 0.03). These data demonstrate that local cooling attenuates sweating by independent effects of decreased skin blood flow and decreased local skin temperature.

  7. Outdoor thermal physiology along human pathways: a study using a wearable measurement system

    NASA Astrophysics Data System (ADS)

    Nakayoshi, Makoto; Kanda, Manabu; Shi, Rui; de Dear, Richard

    2015-05-01

    An outdoor summer study on thermal physiology along subjects' pathways was conducted in a Japanese city using a unique wearable measurement system that measures all the relevant thermal variables: ambient temperature, humidity, wind speed ( U) and short/long-wave radiation ( S and L), along with some physio-psychological parameters: skin temperature ( T skin), pulse rate, subjective thermal sensation and state of body motion. U, S and L were measured using a globe anemo-radiometer adapted use with pedestrian subjects. The subjects were 26 healthy Japanese adults (14 males, 12 females) ranging from 23 to 74 years in age. Each subject wore a set of instruments that recorded individual microclimate and physiological responses along a designated pedestrian route that traversed various urban textures. The subjects experienced varying thermal environments that could not be represented by fixed-point routine observational data. S fluctuated significantly reflecting the mixture of sunlit/shade distributions within complex urban morphology. U was generally low within urban canyons due to drag by urban obstacles such as buildings but the subjects' movements enhanced convective heat exchanges with the atmosphere, leading to a drop in T skin. The amount of sweating increased as standard effective temperature (SET*) increased. A clear dependence of sweating on gender and body size was found; males sweated more than females; overweight subjects sweated more than standard/underweight subjects. T skin had a linear relationship with SET* and a similarly clear dependence on gender and body size differences. T skin of the higher-sweating groups was lower than that of the lower-sweating groups, reflecting differences in evaporative cooling by perspiration.

  8. Thermogenic and psychogenic recruitment of human eccrine sweat glands: Variations between glabrous and non-glabrous skin surfaces.

    PubMed

    Machado-Moreira, Christiano A; Taylor, Nigel A S

    2017-04-01

    Human eccrine sweat-gland recruitment and secretion rates were investigated from the glabrous (volar) and non-glabrous hand surfaces during psychogenic (mental arithmetic) and thermogenic stimuli (mild hyperthermia). It was hypothesised that these treatments would activate glands from both skin surfaces, with the non-thermal stimulus increasing secretion rates primarily by recruiting more sweat glands. Ten healthy men participated in two seated, resting trials in temperate conditions (25-26°C). Trials commenced under normothermic conditions during which the first psychogenic stress was applied. That was followed by passive heating (0.5°C mean body temperature elevation) and thermal clamping, with a second cognitive challenge then applied. Sudomotor activity was evaluated from both hands, with colourimetry used to identify activated sweat glands, skin conductance to determine the onset of precursor sweating and ventilated sweat capsules to measure rates of discharged sweating. From glandular activation and sweat rate data, sweat-gland outputs were derived. These psychogenic and thermogenic stimuli activated sweat glands from both the glabrous and non-glabrous skin surfaces, with the former dominating at the glabrous skin and the latter at the non-glabrous surface. Indeed, those stimuli individually accounted for ~90% of the site-specific maximal number of activated sweat glands observed when both stimuli were simultaneously applied. During the normothermic psychological stimulation, sweating from the glabrous surface was elevated via a 185% increase in the number of activated glands within the first 60s. The hypothetical mechanism for this response may involve the serial activation of additional eccrine sweat glands during the progressive evolution of psychogenic sweating. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. Attenuated thermoregulatory responses with increased plasma osmolality in obese subjects during two seasons

    NASA Astrophysics Data System (ADS)

    Kanikowska, Dominika; Sato, Maki; Sugenoya, Junichi; Shimizu, Yuuki; Nishimura, Naoki; Inukai, Yoko; Iwase, Satoshi

    2013-09-01

    Obese subjects may be more vulnerable to injury from heat stress, and appear to be less efficient at thermoregulation. Sweat rate, tympanic temperature and osmolality in obese subjects were investigated in Japan during two seasons. The purpose of this study was to examine the relationship between obesity, thermoregulatory response and season. Five obese (BMI, 32.0 ± 4.9 kg/m2) and five non-obese (BMI, 23.2 ± 2.9 kg/m2) men participated in this experiment at latitude 35°10' N and longitude 136°57.9'E. The average atmospheric temperature was 29.1 ± 1.0 °C in summer and 3.3 ± 1.4 °C in winter. Tympanic temperature and sweat rate were measured during leg water immersion at 42 °C for 30 min. Blood samples were analyzed for plasma osmolality. The relationship between tympanic temperature and sweat rate decreased significantly in obese compared to in non-obese subjects in both seasons, there being a lowered sweat rate for any core temperature in obese subjects. Plasma osmolality was significantly higher in obese than in non-obese subjects in both seasons. Thermal sensation increased significantly in non-obese than in obese in winter but not in summer. Our data show that thermoregulatory responses are attenuated in obese subjects compared with controls, suggesting that obese people are at increased risk of heat-related illnesses.

  10. High follicle density does not decrease sweat gland density in Huacaya alpacas.

    PubMed

    Moore, K E; Maloney, S K; Blache, D

    2015-01-01

    When exposed to high ambient temperatures, mammals lose heat evaporatively by either sweating from glands in the skin or by respiratory panting. Like other camelids, alpacas are thought to evaporate more water by sweating than panting, despite a thick fleece, unlike sheep which mostly pant in response to heat stress. Alpacas were brought to Australia to develop an alternative fibre industry to sheep wool. In Australia, alpacas can be exposed to ambient temperatures higher than in their native South America. As a young industry there is a great deal of variation in the quality and quantity of the fleece produced in the national flock. There is selection pressure towards animals with finer and denser fleeces. Because the fibre from secondary follicles is finer than that from primary follicles, selecting for finer fibres might alter the ratio of primary and secondary follicles. In turn the selection might alter sweat gland density because the sweat glands are associated with the primary follicle. Skin biopsy and fibre samples were obtained from the mid-section of 33 Huacaya alpacas and the skin sections were processed into horizontal sections at the sebaceous gland level. Total, primary, and secondary follicles and the number of sweat gland ducts were quantified. Fibre samples from each alpaca were further analysed for mean fibre diameter. The finer-fibred animals had a higher total follicle density (P<0.001) and more sweat glands (P<0.001) than the thicker-fibred animals. The fibre diameter and total follicle density were negatively correlated (R(2)=0.56, P<0.001). Given that the finer-fibred animals had higher follicle density and more sweat glands than animals with thicker fibres, we conclude that alpacas with high follicle density should not be limited for potential sweating ability. Copyright © 2014 Elsevier Ltd. All rights reserved.

  11. Sweat allergy: Extrinsic or intrinsic?

    PubMed

    Hiragun, Takaaki; Hiragun, Makiko; Ishii, Kaori; Kan, Takanobu; Hide, Michihiro

    2017-07-01

    Sweat is an exacerbation factor in atopic dermatitis (AD) in all age groups. A body core temperature elevation with sweating triggers cholinergic urticaria (CholU). We recently reported that AD symptoms are improved by tannic acid-containing spray, which suppresses the basophil histamine release induced by semi-purified sweat antigen in vitro, and by showering, which removes antigens in sweat from the skin surface. Sweat contains small amount of proteins including proteases, protease inhibitors, and anti-microbial peptides. We finally identified MGL_1304 secreted by Malassezia (M.) globosa as a major histamine - releasing antigen in human sweat. MGL_1304 is a 17-kDa protein in sweat that elicits almost the highest histamine - release activity from basophils of patients with AD and CholU among antigens derived from Malassezia species. Moreover, serum levels of anti-MGL_1304 IgE were significantly higher in patients with AD and CholU than in normal controls. The recombinant protein produced by Pichia pastoris possessed comparable allergenicity to native MGL_1304. We found a monoclonal IgE antibody against MGL_1304 which did not elicit histamine release from sensitized mast cells. Desensitization therapy using autologous sweat, or MGL_1304 purified from culture of M. globosa or its cognates might be beneficial for patients with intractable CholU due to sweat allergy. Copyright © 2017 Japanese Society for Investigative Dermatology. Published by Elsevier B.V. All rights reserved.

  12. Store-operated Ca2+ entry regulates Ca2+-activated chloride channels and eccrine sweat gland function.

    PubMed

    Concepcion, Axel R; Vaeth, Martin; Wagner, Larry E; Eckstein, Miriam; Hecht, Lee; Yang, Jun; Crottes, David; Seidl, Maximilian; Shin, Hyosup P; Weidinger, Carl; Cameron, Scott; Turvey, Stuart E; Issekutz, Thomas; Meyts, Isabelle; Lacruz, Rodrigo S; Cuk, Mario; Yule, David I; Feske, Stefan

    2016-11-01

    Eccrine sweat glands are essential for sweating and thermoregulation in humans. Loss-of-function mutations in the Ca2+ release-activated Ca2+ (CRAC) channel genes ORAI1 and STIM1 abolish store-operated Ca2+ entry (SOCE), and patients with these CRAC channel mutations suffer from anhidrosis and hyperthermia at high ambient temperatures. Here we have shown that CRAC channel-deficient patients and mice with ectodermal tissue-specific deletion of Orai1 (Orai1K14Cre) or Stim1 and Stim2 (Stim1/2K14Cre) failed to sweat despite normal sweat gland development. SOCE was absent in agonist-stimulated sweat glands from Orai1K14Cre and Stim1/2K14Cre mice and human sweat gland cells lacking ORAI1 or STIM1 expression. In Orai1K14Cre mice, abolishment of SOCE was associated with impaired chloride secretion by primary murine sweat glands. In human sweat gland cells, SOCE mediated by ORAI1 was necessary for agonist-induced chloride secretion and activation of the Ca2+-activated chloride channel (CaCC) anoctamin 1 (ANO1, also known as TMEM16A). By contrast, expression of TMEM16A, the water channel aquaporin 5 (AQP5), and other regulators of sweat gland function was normal in the absence of SOCE. Our findings demonstrate that Ca2+ influx via store-operated CRAC channels is essential for CaCC activation, chloride secretion, and sweat production in humans and mice.

  13. Can supine recovery mitigate the exercise intensity dependent attenuation of post-exercise heat loss responses?

    PubMed

    Kenny, Glen P; Gagnon, Daniel; Jay, Ollie; McInnis, Natalie H; Journeay, W Shane; Reardon, Francis D

    2008-08-01

    Cutaneous vascular conductance (CVC) and sweat rate are subject to non-thermal baroreflex-mediated attenuation post-exercise. Various recovery modalities have been effective in attenuating these decreases in CVC and sweat rate post-exercise. However, the interaction of recovery posture and preceding exercise intensity on post-exercise thermoregulation remains unresolved. We evaluated the combined effect of supine recovery and exercise intensity on post-exercise cardiovascular and thermal responses relative to an upright seated posture. Seven females performed 15 min of cycling ergometry at low- (LIE, 55% maximal oxygen consumption) or high-(HIE, 85% maximal oxygen consumption) intensity followed by 60 min of recovery in either an upright seated or supine posture. Esophageal temperature, CVC, sweat rate, cardiac output, stroke volume, heart rate, total peripheral resistance, and mean arterial pressure (MAP) were measured at baseline, at end-exercise, and at 2, 5, 12, 20, and every 10 min thereafter until the end of recovery. MAP and stroke volume were maintained during supine recovery to a greater extent relative to an upright seated recovery following HIE (p

  14. Seasonal Acclimatization in Summer versus Winter to Changes in the Sweating Response during Passive Heating in Korean Young Adult Men.

    PubMed

    Lee, Jeong-Beom; Kim, Tae-Wook; Min, Young-Ki; Yang, Hun-Mo

    2015-01-01

    We investigated the sweating response during passive heating (partial submersion up to the umbilical line in 42±0.5℃ water, 30 min) after summer and winter seasonal acclimatization (SA). Testing was performed in July during the summer, 2011 [summer-SA; temp, 25.6±1.8℃; relative humidity (RH), 82.1±8.2%] and in January during the winter, 2012 (winter-SA; temp, -2.7±2.9℃; RH, 65.0±13.1%) in Cheonan (126°52'N, 33.38'E), Republic of Korea. All experiments were carried out in an automated climatic chamber (temp, 25.0±0.5℃: RH, 60.0±3.0%). Fifteen healthy men (age, 23.4±2.5 years; height, 175.0±5.9 cm; weight, 65.3±6.1 kg) participated in the study. Local sweat onset time was delayed during winter-SA compared to that after summer-SA (p< 0.001). Local sweat volume, whole body sweat volume, and evaporative loss volume decreased significantly after winter-SA compared to those after summer-SA (p<0.001). Changes in basal metabolic rate increased significantly after winter-SA (p< 0.001), and tympanic temperature and mean body temperature were significantly lower after summer-SA (p<0.05). In conclusion, central sudomotor acitivity becomes sensitive to summer-SA and blunt to winter-SA in Rebubic of Korea. These results suggest that the body adjusts its temperature by economically controlling the sweating rate but does not lower the thermal dissipation rate through a more effective evaporation scheme after summer-SA than that after winter-SA.

  15. Fluid-electrolyte shifts and thermoregulation - Rest and work in heat with head cooling

    NASA Technical Reports Server (NTRS)

    Greenleaf, J. E.; Van Beaumont, W.; Brock, P. J.; Montgomery, L. D.; Morse, J. T.; Shvartz, E.; Kravik, S.

    1980-01-01

    The effects of head cooling on thermoregulation and associated plasma fluid and electrolyte shifts during rest and submaximal exercise in the heat are investigated. Thermoregulatory responses and plasma volume were measured in four male subjects fitted with liquid-cooled neoprene headgear during 60 min of rest, 60 min of ergometer exercise at 45% maximal oxygen uptake and 30 min of recovery in the supine position at 40.1 C and 40% relative humidity. It is found that, compared to control responses, head cooling decreased thigh sweating and increased mean skin temperature at rest and attenuated increases in thigh sweating, heart rate, rectal temperature and ventilation during exercise. During recovery, cooling is observed to facilitate decreases in sweat rate, heart rate, rectal temperature and forearm blood flow and enhance the increase in average temperature. Cooling had no effect on plasma protein, osmotic or electrolyte shifts, and decreased plasma volume losses. The findings indicate the effectiveness of moderate head cooling for the improvement of human performance during exercise in heat.

  16. Comparison of thermoregulatory responses to heat between Malaysian and Japanese males during leg immersion.

    PubMed

    Wijayanto, Titis; Wakabayashi, Hitoshi; Lee, Joo-Young; Hashiguchi, Nobuko; Saat, Mohamed; Tochihara, Yutaka

    2011-07-01

    The objective of this study was to investigate thermoregulatory responses to heat in tropical (Malaysian) and temperate (Japanese) natives, during 60 min of passive heating. Ten Japanese (mean ages: 20.8 ± 0.9 years) and ten Malaysian males (mean ages: 22.3 ± 1.6 years) with matched morphological characteristics and physical fitness participated in this study. Passive heating was induced through leg immersion in hot water (42°C) for 60 min under conditions of 28°C air temperature and 50% RH. Local sweat rate on the forehead and thigh were significantly lower in Malaysians during leg immersion, but no significant differences in total sweat rate were observed between Malaysians (86.3 ± 11.8 g m(-2) h(-1)) and Japanese (83.2 ± 6.4 g m(-2) h(-1)) after leg immersion. In addition, Malaysians displayed a smaller rise in rectal temperature (0.3 ± 0.1°C) than Japanese (0.7 ± 0.1°C) during leg immersion, with a greater increase in hand skin temperature. Skin blood flow was significantly lower on the forehead and forearm in Malaysians during leg immersion. No significant different in mean skin temperature during leg immersion was observed between the two groups. These findings indicated that regional differences in body sweating distribution might exist between Malaysians and Japanese during heat exposure, with more uniform distribution of local sweat rate over the whole body among tropical Malaysians. Altogether, Malaysians appear to display enhanced efficiency of thermal sweating and thermoregulatory responses in dissipating heat loss during heat loading. Thermoregulatory differences between tropical and temperate natives in this study can be interpreted as a result of heat adaptations to physiological function.

  17. PIXE analysis of cystic fibrosis sweat samples with an external proton beam

    NASA Astrophysics Data System (ADS)

    Sommer, F.; Massonnet, B.

    1987-03-01

    PIXE analysis with an external proton beam is used to study, in four control and five cystic fibrosis children, the elemental composition of sweat samples collected from different parts of the body during entire body hyperthermia. We observe no significant difference of sweat rates and of temperature variations between the two groups during sweat test. The statistical study of results obtained by PIXE analysis allows us to pick out amongst 8 elements studied, 6 elements (Na, Cl, Ca, Mn, Cu, Br) significatively different between the two groups of subjects. Using regression analysis, Na, Cl and Br concentrations could be used in a predictive equation of the state of health.

  18. Store-operated Ca2+ entry regulates Ca2+-activated chloride channels and eccrine sweat gland function

    PubMed Central

    Concepcion, Axel R.; Vaeth, Martin; Wagner, Larry E.; Eckstein, Miriam; Hecht, Lee; Yang, Jun; Crottes, David; Seidl, Maximilian; Shin, Hyosup P.; Weidinger, Carl; Cameron, Scott; Turvey, Stuart E.; Issekutz, Thomas; Meyts, Isabelle; Lacruz, Rodrigo S.; Cuk, Mario; Yule, David I.

    2016-01-01

    Eccrine sweat glands are essential for sweating and thermoregulation in humans. Loss-of-function mutations in the Ca2+ release–activated Ca2+ (CRAC) channel genes ORAI1 and STIM1 abolish store-operated Ca2+ entry (SOCE), and patients with these CRAC channel mutations suffer from anhidrosis and hyperthermia at high ambient temperatures. Here we have shown that CRAC channel–deficient patients and mice with ectodermal tissue–specific deletion of Orai1 (Orai1K14Cre) or Stim1 and Stim2 (Stim1/2K14Cre) failed to sweat despite normal sweat gland development. SOCE was absent in agonist-stimulated sweat glands from Orai1K14Cre and Stim1/2K14Cre mice and human sweat gland cells lacking ORAI1 or STIM1 expression. In Orai1K14Cre mice, abolishment of SOCE was associated with impaired chloride secretion by primary murine sweat glands. In human sweat gland cells, SOCE mediated by ORAI1 was necessary for agonist-induced chloride secretion and activation of the Ca2+-activated chloride channel (CaCC) anoctamin 1 (ANO1, also known as TMEM16A). By contrast, expression of TMEM16A, the water channel aquaporin 5 (AQP5), and other regulators of sweat gland function was normal in the absence of SOCE. Our findings demonstrate that Ca2+ influx via store-operated CRAC channels is essential for CaCC activation, chloride secretion, and sweat production in humans and mice. PMID:27721237

  19. Absence of arterial baroreflex modulation of skin sympathetic activity and sweat rate during whole-body heating in humans

    NASA Technical Reports Server (NTRS)

    Wilson, T. E.; Cui, J.; Crandall, C. G.

    2001-01-01

    1. Prior findings suggest that baroreflexes are capable of modulating skin blood flow, but the effects of baroreceptor loading/unloading on sweating are less clear. Therefore, this project tested the hypothesis that pharmacologically induced alterations in arterial blood pressure in heated humans would lead to baroreflex-mediated changes in both skin sympathetic nerve activity (SSNA) and sweat rate. 2. In seven subjects mean arterial blood pressure was lowered (approximately 8 mmHg) and then raised (approximately 13 mmHg) by bolus injections of sodium nitroprusside and phenylephrine, respectively. Moreover, in a separate protocol, arterial blood pressure was reduced via steady-state administration of sodium nitroprusside. In both normothermia and heat-stress conditions the following responses were monitored: sublingual and mean skin temperatures, heart rate, beat-by-beat blood pressure, skin blood flow (laser-Doppler flowmetry), local sweat rate and SSNA (microneurography from peroneal nerve). 3. Whole-body heating increased skin and sublingual temperatures, heart rate, cutaneous blood flow, sweat rate and SSNA, but did not change arterial blood pressure. Heart rate was significantly elevated (from 74 +/- 3 to 92 +/- 4 beats x min(-1); P < 0.001) during bolus sodium nitroprusside-induced reductions in blood pressure, and significantly reduced (from 92 +/- 4 to 68 +/- 4 beats x min(-1); P < 0.001) during bolus phenylephrine-induced elevations in blood pressure, thereby demonstrating normal baroreflex function in these subjects. 4. Neither SSNA nor sweat rate was altered by rapid (bolus infusion) or sustained (steady-state infusion) changes in blood pressure regardless of the thermal condition. 5. These data suggest that SSNA and sweat rate are not modulated by arterial baroreflexes in normothermic or moderately heated individuals.

  20. Hydration: special issues for playing football in warm and hot environments.

    PubMed

    Shirreffs, S M

    2010-10-01

    The high metabolic rates and body temperatures sustained by football players during training and matches causes sweating--particularly when in warm or hot environments. There is limited published data on the effects of this sweat loss on football performance. The limited information available, together with knowledge of the effects of sweat loss in other sports with skill components as well as endurance and sprint components, suggests that the effects of sweating will be similar as in these other activities. Therefore, the generalization that, on average, a body mass reduction equivalent to 2% should be the acceptable limit of sweat losses seems reasonable. This magnitude and more, of sweat loss is a common occurrence for some players. Sodium is the main electrolyte lost in sweat but there is large variability in sodium losses between players. However, the extent of sodium losses in some players may be such that its replacement is warranted for these players. Although football is a team sport, the great individual variability in sweat and electrolyte losses of players in the same training session or match dictates that individual monitoring to determine individual water and electrolyte requirements should be an essential part of a player's nutrition strategy. © 2010 John Wiley & Sons A/S.

  1. Thermoregulatory models of safety-for-flight issues for space operations

    NASA Astrophysics Data System (ADS)

    Pisacane, V. L.; Kuznetz, L. H.; Logan, J. S.; Clark, J. B.; Wissler, E. H.

    2006-10-01

    This study investigates the use of a mathematical model for thermoregulation as a tool in safety-of-flight issues and proposed solutions for mission operations of the Space Shuttle and the International Space Station. Specifically, this study assesses the effects of elevated cabin temperature and metabolic loads on astronauts wearing the Advanced Crew Escape Suit (ACES) and the Liquid Cooled Ventilation Garment (LCVG). The 225-node Wissler model is validated by comparison with two ground-based human subject tests, firefighters, and surrogate astronauts under anomalous conditions that show good agreement. Subsequent simulations indicate that the performance of the ACES/LCVG is marginal. Increases in either workload or cabin temperature from the nominal will increase rectal temperature, stored heat load, heart rate, and sweating leading to possible deficits in the ability of the astronauts to perform cognitive and motor tasks that could affect the safety of the mission, especially the safe landing of the Shuttle. Specific relationships are given between cabin temperature and metabolic rate that define the threshold for decreased manual dexterity and loss of tracking skills. Model results indicate that the most effective mitigation strategy would be to decrease the LCVG inlet temperature. Methods of accomplishing this are also proposed.

  2. Human Responses to Exercise-Heat Stress

    DTIC Science & Technology

    1993-11-01

    temperature Is usually regulated within a narrowv range (350 to 41 * G ). This is accomplished through two parallel processes: behaviora’ temperature...min (245 kJ.°C"+38.4 kJ.min"). Since the latent heat of evaporation for sweat is 2.43 kJ- g ", this man would need to evaporate -16 g of sweat per min...wgT reduce physiological strain and improve exercise performance during subsequent heat exposures’. Exercise in the heat is the most 4Ac& g to a

  3. Sweat output measurement of the post-ganglion sudomotor response by Q-Sweat Test: a normative database of Chinese individuals

    PubMed Central

    2012-01-01

    Background Q-Sweat is a model used for evaluating the post-ganglionic sudomotor function by assessing sweat response. This study aimed to establish the normative database of Q-Sweat test among Chinese individuals since this type of information is currently lacking. Results One hundred and fifty (150) healthy volunteers, 76 men and 74 women with age range of 22–76 years were included. Skin temperature and sweat onset latency measured at the four sites (i.e., the forearm, proximal leg, distal leg, and the foot) did not significantly correlate with age, gender, body height (BH), body weight (BW), and body mass index (BMI) but the total sweat volume measured in all four sites significantly correlated with sex, BH, and BW. Except for the distal leg, the total sweat volume measured at the other three sites had a significant correlation with BMI. In terms of gender, men had larger total sweat volume, with median differences at the forearm, proximal leg, distal leg, and foot of 0.591 μl, 0.693 μl, 0.696 μl, and 0.358 μl, respectively. Regarding BW difference (≥62 and < 62 Kg), those with BW ≥62 Kg had larger total sweat volume. Median differences at the forearm, proximal leg, distal leg, and foot were 0.538 μl, 0.744 μl, 0.695 μl, and 0.338 μl, respectively. There was an uneven distribution of male and female participants in the two BW groups. In all conditions, the total sweat volume recorded at the foot site was the smallest. Conclusion This is the first report to show the normative database of sweat response in Chinese participants evaluated using Q-Sweat device. This normative database can help guide further research on post-ganglionic sudomotor or related clinical practice involving a Chinese population. PMID:22682097

  4. The Effect of an Amino Acid Infusion on Central Thermoregulatory Control in Humans

    PubMed Central

    Nakajima, Yasufumi; Takamata, Akira; Matsukawa, Takashi; Sessler, Daniel I.; Kitamura, Yoshihiro; Ueno, Hiroshi; Tanaka, Yoshifumi; Mizobe, Toshiki

    2005-01-01

    Background Administration of protein or amino acids enhances thermogenesis, presumably by stimulating oxidative metabolism. However, hyperthermia results even when thermoregulatory responses are intact, suggesting that amino acids also alter central thermoregulatory control. We thus tested the hypothesis that amino acid infusion increases the thermoregulatory setpoint. Methods Nine male volunteers each participated on four study days in randomized order: 1) intravenous amino acids infused at 4 kJ·kg−1·hr−1 for 2.5 h combined with skin-surface warming; 2) amino acid infusion combined with cutaneous cooling; 3) a saline infusion combined with skin-surface warming; and, 4) saline infusion combined with cutaneous cooling. Results Amino acid infusion increased resting core temperature by 0.3 ± 0.1°C (mean ± SD) and oxygen consumption by 18 ± 12%. Furthermore, amino acid infusion increased the calculated core temperature threshold (triggering core temperature at a designated mean-skin temperature of 34°C) for active cutaneous vasodilation by 0.3 ± 0.3°C, for sweating by 0.2 ± 0.2°C, for thermoregulatory vasoconstriction by 0.3 ± 0.3°C, and for thermogenesis by 0.4 ± 0.5°C. Amino acid infusion did not alter the incremental response intensity (i.e., gain) of thermoregulatory defenses. Conclusions Amino acid infusion increased the metabolic rate and resting core temperature. However, amino acids also produced a synchronous increase in all major autonomic thermoregulatory defense thresholds; the increase in core temperature was identical to the setpoint increase — even in a cold environment with amble potential to dissipate heat. In subjects with intact thermoregulatory defenses, amino acid-induced hyperthermia appears to result from an elevated setpoint increase rather than increased metabolic rate per se. PMID:15108979

  5. Exercise and Fluid Balance Update

    ERIC Educational Resources Information Center

    Schlicht, Jeff

    2005-01-01

    One common piece of advice that exercise professionals give their clients is to drink water before, during, and after exercise. During exercise people can lose as much as three liters of water per hour (about 100 ounces) through sweat. Dehydration alters normal sweat patterns, which can lead to an increased core body temperature. Since most of the…

  6. Assessing the impact of egg sweating on Salmonella Enteritidis penetration into shell eggs

    USDA-ARS?s Scientific Manuscript database

    Salmonella Enteritidis (SE) prevalence in eggs is a major concern to the egg industry. Some research has shown that egg sweating can increase Salmonella penetration into egg contents when refrigerated eggs are moved to a warmer temperature. This occurs when eggs are tempered before wash, to minimize...

  7. Evaporative water loss in the new-born baby

    PubMed Central

    Hey, E. N.; Katz, G.

    1969-01-01

    1. Measurements of total evaporative water loss (EWL) were made on sixty-three premature and full-term babies 0-65 days after birth within a closed Perspex chamber under varied environmental conditions by measuring the flow and absolute humidity of air entering and leaving the chamber. Control experiments suggested that the method underestimated loss by about 5%. Measurements of O2 consumption were made concurrently by recording the volume change of the closed gas circuit. 2. The total basal EWL averaged 10·8 g H2O/m2.hr in infants 2-10 days old when ambient water vapour pressure (PH2O) was 18 mm Hg; basal EWL was correlated with basal metabolic rate at all ages studied and evaporative heat loss accounted for ∼ 23% of basal heat production. 3. Respiratory water loss was measured by detecting the water added to air at 33° C passed across the face of eight infants in a trunk plethysmograph. Respiratory water loss was inversely related to the water vapour content of the inspired air; gas appeared to leave the nose ∼ 95% sat. at 35·6° C. 4. Measurements of total EWL were obtained when humidity was varied and skin loss was calculated by subtracting estimated respiratory loss from total loss; changing PH2O from 7 to 25 mm Hg appeared to decrease basal skin water loss by only 1·5 g/m2.hr. 5. No consistent changes in EWL were obtained when environmental temperature (TE) was varied between 28 and 34° C. Active sweating occurred in infants 0-10 days old born within 3 weeks of term when TE exceeded 34-35° C and rectal temperature (TR) rose above 37·2° C. The threshold rectal temperature at which sweating was detected fell significantly in the first 10 days of life; EWL increased two to fourfold when TR rose to between 37·5 and 37·8° C. 6. In infants of less than 215 days post-conceptual age (term ∼ 268 days) EWL increased less than 50% at TR 37·7-37·8° C; it is concluded that the sweating mechanism is defective in these infants. PMID:5765850

  8. Effects of hyperoxia on thermoregulatory responses during feet immersion to hot water in humans.

    PubMed

    Yamashita, Kazuaki; Tochihara, Yutaka

    2003-07-01

    This study examined effects of hyperoxia on thermoregulatory responses. Eight healthy male students (23.5+/-1.8 yrs) were involved in this study. They immersed their legs in a hot water bath (42 degrees C) for 60 minutes in a climate chamber. The conditions of oxygen concentration of a chamber were set at 21% (control), 25% (25%O(2)), and 30% (30%O(2)). Ambient temperature and relative humidity was maintained at 25 degrees C and 50% in every condition, respectively. Measurements included rectal temperature (Tre), skin temperature at 7 sites, laser Doppler flowmeter (LDF) on the back and forearm as an index of skin blood flow, heart rate, local sweat rate (Msw) on the back and forearm, and total body weight loss (BWL). Increases of Tre at 25%O(2) and 30%O(2) tended to be lower during the immersion than in the control. Mean skin temperature (Tsk) of the control increased gradually after the onset of sweating, while the Tsks at 25%O(2) and 30%O(2) maintained a constant level during sweating. LDFs on the forearm at 25%O(2) and 30%O(2) showed lower increases compared with the control. No significant differences in Msw on the back and the forearm and BWL were seen among the conditions. These results suggested that hyperoxia could not affect sweating responses but elicit an inhibitory effect on thermoregulatory skin blood flow.

  9. Eccrine sweat gland development and sweat secretion

    PubMed Central

    Cui, Chang-Yi; Schlessinger, David

    2017-01-01

    Eccrine sweat glands help to maintain homoeostasis, primarily by stabilizing body temperature. Derived from embryonic ectoderm, millions of eccrine glands are distributed across human skin and secrete litres of sweat per day. Their easy accessibility has facilitated the start of analyses of their development and function. Mouse genetic models find sweat gland development regulated sequentially by Wnt, Eda and Shh pathways, although precise subpathways and additional regulators require further elucidation. Mature glands have two secretory cell types, clear and dark cells, whose comparative development and functional interactions remain largely unknown. Clear cells have long been known as the major secretory cells, but recent studies suggest that dark cells are also indispensable for sweat secretion. Dark cell-specific Foxa1 expression was shown to regulate a Ca2+-dependent Best2 anion channel that is the candidate driver for the required ion currents. Overall, it was shown that cholinergic impulses trigger sweat secretion in mature glands through second messengers – for example InsP3 and Ca2+ – and downstream ion channels/transporters in the framework of a Na+-K+-Cl− cotransporter model. Notably, the microenvironment surrounding secretory cells, including acid–base balance, was implicated to be important for proper sweat secretion, which requires further clarification. Furthermore, multiple ion channels have been shown to be expressed in clear and dark cells, but the degree to which various ion channels function redundantly or indispensably also remains to be determined. PMID:26014472

  10. Effect of sodium and calcium ingestion on thermoregulation during exercise in man

    NASA Technical Reports Server (NTRS)

    Greenleaf, J. E.; Brock, P. J.; Morse, J. T.; Van Beaumont, W.; Montgomery, L. D.; Convertino, V. A.; Mangseth, G. R.

    1978-01-01

    The effects of hypertonic sodium and calcium ingestion on body temperature during exercise in cool and hot environments are investigated. Rectal and mean skin temperatures, sweat rates and arm and leg total blood flows were measured in men during periods of rest, submaximal exercise and recovery at temperatures of 26.5 C and 39.4 C after ingestion of NaCl and CaCl2 solutions. In both environments, higher rectal temperatures are observed after hypertonic sodium ingestion, which is also associated with attenuated blood flow in the extremities, lower sweat rates and slightly higher skin temperature in the heat, indicating significant thermoregulatory responses. Hypertonic calcium and isotonic sodium cause no temperature change, although calcium caused a reduction of blood flow in the extremities.

  11. Thermoregulation During Spaceflight

    NASA Technical Reports Server (NTRS)

    Greenleaf, John E.; Fortney, Suzanne M.

    1992-01-01

    The purpose of this flight proposal is to investigate human thermoregulatory parameters during exercise in microgravity. The hypothesis to be tested is that microgravity-adopted astronauts will exhibit accentuated increases in their core temperature (excess hyperthermia) during exercise because of altered heat loss responses due to reduced sweating and/or accentuated vasodilation. The specific aims are (1) to compare core and skin temperature responses during moderate exercise before flight and inflight; (2) to determine whether the hypothesized inflight excessive hyperthermia is due to increased heat production, reduced, sweating, impaired peripheral vasodilation, or to some combination of these factors; and (3) to determine whether heat production at an exercise load of 60 percent of the maximal working capacity is similar preflight and inflight. It is expected that the astronauts will exhibit excessive hyperthermia during exposure to microgravity which will be caused by decreased sweating and decreased skin blood flow.

  12. [Studies on the health standard for room temperature in cold regions].

    PubMed

    Meng, Z L

    1990-03-01

    The microclimate of 205 rooms of single storey houses in four new rural residential districts in coastal and inland Shandong was monitored and studied the blood circulation of the finger, skin temperature, sweating function and other physiological indexes among 2,401 peasants. We interrogated their personal sensation to cold and warmth. The count was done by the application of thermal equilibrium index (TEI), predicted 4-hour Sweat Rate (P4SR) and the uncomfortable index. The standard room temperature is recommended as follows. In rural area in winter the appropriate room temperature is 14-16 degrees C, the comfortable room temperature is 16-20 degrees C, the lowest room temperature must not be below 14 degrees C. In summer the appropriate room temperature is 25-28 degrees C, the comfortable room temperature is 26-27 degrees C, the highest temperature must not be above 28 degrees C.

  13. Hydrochromic Approaches to Mapping Human Sweat Pores.

    PubMed

    Park, Dong-Hoon; Park, Bum Jun; Kim, Jong-Man

    2016-06-21

    Hydrochromic materials, which undergo changes in their light absorption and/or emission properties in response to water, have been extensively investigated as humidity sensors. Recent advances in the design of these materials have led to novel applications, including monitoring the water content of organic solvents, water-jet-based rewritable printing on paper, and hydrochromic mapping of human sweat pores. Our interest in this area has focused on the design of hydrochromic materials for human sweat pore mapping. We recognized that materials appropriate for this purpose must have balanced sensitivities to water. Specifically, while they should not undergo light absorption and/or emission transitions under ambient moisture conditions, the materials must have sufficiently high hydrochromic sensitivities that they display responses to water secreted from human sweat pores. In this Account, we describe investigations that we have carried out to develop hydrochromic substances that are suitable for human sweat pore mapping. Polydiacetylenes (PDAs) have been extensively investigated as sensor matrices because of their stimulus-responsive color change property. We found that incorporation of headgroups composed of hygroscopic ions such as cesium or rubidium and carboxylate counterions enables PDAs to undergo a blue-to-red colorimetric transition as well as a fluorescence turn-on response to water. Very intriguingly, the small quantities of water secreted from human sweat pores were found to be sufficient to trigger fluorescence turn-on responses of the hydrochromic PDAs, allowing precise mapping of human sweat pores. Since the hygroscopic ion-containing PDAs developed in the initial stage display a colorimetric transition under ambient conditions that exist during humid summer periods, a new system was designed. A PDA containing an imidazolium ion was found to be stable under all ambient conditions and showed temperature-dependent hydrochromism corresponding to a colorimetric change near body temperature. This feature enables the use of this technique to generate high-quality images of sweat pores. This Account also focuses on the results of the most recent phase of this investigation, which led to the development of a simple yet efficient and reliable technique for sweat pore mapping. The method utilizes a hydrophilic polymer composite film containing fluorescein, a commercially available dye that undergoes a fluorometric response as a result of water-dependent interconversion between its ring-closed spirolactone (nonfluorescent) and ring-opened fluorone (fluorescent) forms. Surface-modified carbon nanodots (CDs) have also been found to be efficient for hydrochromic mapping of human sweat pores. The results discovered by Lou et al. [ Adv. Mater. 2015 , 27 , 1389 ] are also included in this Account. Sweat pore maps obtained from fingertips using these materials were found to be useful for fingerprint analysis. In addition, this hydrochromism-based approach is sufficiently sensitive to enable differentiation between sweat-secreting active pores and inactive pores. As a result, the techniques can be applied to clinical diagnosis of malfunctioning sweat pores. The directions that future research in this area will follow are also discussed.

  14. Effect of local cooling on sweating rate and cold sensation

    NASA Technical Reports Server (NTRS)

    Crawshaw, L. I.; Nadel, E. R.; Stolwijk, J. A. J.; Stamford, B. A.

    1975-01-01

    Subjects resting in a 39 C environment were stimulated in different skin regions with a water-cooled thermode. Results indicate that cooling different body regions produces generally equivalent decreases in sweating rate and increases in cold sensation, with the forehead showing a much greater sensitivity per unit area and temperature decrease than other areas. The high thermal sensitivity of the face may have evolved when it was the thinnest-furred area of the body; today's clothing habits have reestablished the importance of the face in the regulation of body temperature.

  15. Single nucleotide polymorphisms associated with thermoregulation in lactating dairy cows exposed to heat stress.

    PubMed

    Dikmen, S; Wang, X-z; Ortega, M S; Cole, J B; Null, D J; Hansen, P J

    2015-12-01

    Dairy cows with increased rectal temperature experience lower milk yield and fertility. Rectal temperature during heat stress is heritable, so genetic selection for body temperature regulation could reduce effects of heat stress on production. One aim of the study was to validate the relationship between genotype and heat tolerance for single nucleotide polymorphisms (SNPs) previously associated with resistance to heat stress. A second aim was to identify new SNPs associated with heat stress resistance. Thermotolerance was assessed in lactating Holsteins during the summer by measuring rectal temperature (a direct measurement of body temperature regulation; n = 435), respiration rate (an indirect measurement of body temperature regulation, n = 450) and sweating rate (the major evaporative cooling mechanism in cattle, n = 455). The association between genotype and thermotolerance was evaluated for 19 SNPs previously associated with rectal temperature from a genomewide analysis study (GWAS), four SNPs previously associated with change in milk yield during heat stress from GWAS, 2 candidate gene SNPs previously associated with rectal temperature and respiration rate during heat stress (ATPA1A and HSP70A) and 66 SNPs in genes previously shown to be associated with reproduction, production or health traits in Holsteins. For SNPs previously associated with heat tolerance, regions of BTA4, BTA6 and BTA24 were associated with rectal temperature; regions of BTA6 and BTA24 were associated with respiration rate; and regions of BTA5, BTA26 and BTA29 were associated with sweating rate. New SNPs were identified for rectal temperature (n = 12), respiration rate (n = 8) and sweating rate (n = 3) from among those previously associated with production, reproduction or health traits. The SNP that explained the most variation were PGR and ASL for rectal temperature, ACAT2 and HSD17B7 for respiration rate, and ARL6IP1 and SERPINE2 for sweating rate. ARL6IP1 was associated with all three thermotolerance traits. In conclusion, specific genetic markers responsible for genetic variation in thermoregulation during heat stress in Holsteins were identified. These markers may prove useful in genetic selection for heat tolerance in Holstein cattle. © 2015 Blackwell Verlag GmbH.

  16. Effects of short-term exercise in the heat on thermoregulation, blood parameters, sweat secretion and sweat composition of tropic-dwelling subjects.

    PubMed

    Saat, Mohamed; Sirisinghe, Roland Gamini; Singh, Rabindarjeet; Tochihara, Yutaka

    2005-09-01

    This study investigates the effects of a short-term aerobic training program in a hot environment on thermoregulation, blood parameters, sweat secretion and composition in tropic-dwellers who have been exposed to passive heat. Sixteen healthy Malaysian-Malay male volunteers underwent heat acclimation (HA) by exercising on a bicycle ergometer at 60% of VO2max for 60 min each day in a hot environment (Ta: 31.1+/-0.1 degrees C, rh: 70.0+/-4.4%) for 14 days. All parameters mentioned above were recorded on Day 1 and at the end of HA (Day 16). On these two days, subjects rested for 10 min, then cycled at 60% of VO2max for 60 min and rested again for 20 min (recovery) in an improvised heat chamber. Rectal temperature (Tre), mean skin temperature (Tsk) heart rate (HR), ratings of perceived exertion (RPE), thermal sensation (TS), local sweat rate and percent dehydration were recorded during the test. Sweat concentration was analysed for sodium [Na+]sweat and potassium. Blood samples were analysed for biochemical changes, electrolytes and hematologic indices. Urine samples were collected before and after each test and analysed for electrolytes.After the period of acclimation the percent dehydration during exercise significantly increased from 1.77+/-0.09% (Day 1) to 2.14+/-0.07% (Day 16). Resting levels of hemoglobin, hematocrit and red blood cells decreased significantly while [Na+]sweat increased significantly. For Tre and Tsk there were no differences at rest. Tre, HR, RPE, TS, plasma lactate concentration, hemoglobin and hematocrit at the 40th min of exercise were significantly lower after the period of acclimation but mean corpuscular hemoglobin and serum osmolality were significantly higher while no difference was seen in [Na+]sweat and Tsk. It can be concluded that tropic-dwelling subjects, although exposed to prolonged passive heat exposure, were not fully heat acclimatized. To achieve further HA, they should gradually expose themselves to exercise-heat stress in a hot environment.

  17. Eccrine sweat gland development and sweat secretion.

    PubMed

    Cui, Chang-Yi; Schlessinger, David

    2015-09-01

    Eccrine sweat glands help to maintain homoeostasis, primarily by stabilizing body temperature. Derived from embryonic ectoderm, millions of eccrine glands are distributed across human skin and secrete litres of sweat per day. Their easy accessibility has facilitated the start of analyses of their development and function. Mouse genetic models find sweat gland development regulated sequentially by Wnt, Eda and Shh pathways, although precise subpathways and additional regulators require further elucidation. Mature glands have two secretory cell types, clear and dark cells, whose comparative development and functional interactions remain largely unknown. Clear cells have long been known as the major secretory cells, but recent studies suggest that dark cells are also indispensable for sweat secretion. Dark cell-specific Foxa1 expression was shown to regulate a Ca(2+) -dependent Best2 anion channel that is the candidate driver for the required ion currents. Overall, it was shown that cholinergic impulses trigger sweat secretion in mature glands through second messengers - for example InsP3 and Ca(2+) - and downstream ion channels/transporters in the framework of a Na(+) -K(+) -Cl(-) cotransporter model. Notably, the microenvironment surrounding secretory cells, including acid-base balance, was implicated to be important for proper sweat secretion, which requires further clarification. Furthermore, multiple ion channels have been shown to be expressed in clear and dark cells, but the degree to which various ion channels function redundantly or indispensably also remains to be determined. Published 2015. This article is a U.S. Government work and is in the public domain in the USA.

  18. Physiologic reactions during five weeks of continuous residence in an artificial humid and hot climate

    NASA Technical Reports Server (NTRS)

    Laaser, U.

    1979-01-01

    During 5 weeks in a climatic room, total sweat during work almost doubled. Initial hour differences increasingly equalized. There was a displacement of sweat secretion from trunk to extremities till the end of week 3, occurring earlier and more clearly for the arm than for the leg. Work temperatures dropped rapidly and evenly to a constant level by day 11. Circulation behavior matched that of temperature. Pulse rate during work dropped like rectal temperature and pulse rate during rest was phasically like the pattern of corresponding temperatures. Except for the first days urine output was adequate and even, Na decreasing in the urine until week 3, then returning to initial values. Na and K in sweat declined but with opposite patterns for hours 1-4. Total salt elimination decreased. The conclusive phenomena of redistribution occurred within the first 3 weeks. A few functions changed later also. Relatively trivial changes in an otherwise uniform reaction pattern indicated that after 3 or even 5 weeks of acclimatization the process is not over or at least not completely so. The tempo of the process appears to be a function of the degree of loading.

  19. The mechanisms underlying the muscle metaboreflex modulation of sweating and cutaneous blood flow in passively heated humans.

    PubMed

    Haqani, Baies; Fujii, Naoto; Kondo, Narihiko; Kenny, Glen P

    2017-02-01

    Metaboreceptors can modulate cutaneous blood flow and sweating during heat stress but the mechanisms remain unknown. Fourteen participants (31 ± 13 years) performed 1-min bout of isometric handgrip (IHG) exercise at 60% of their maximal voluntary contraction followed by a 3-min occlusion (OCC), each separated by 10 min, initially under low (LHS, to activate sweating without changes in core temperature) and high (HHS, whole-body heating to a core temperature increase of 1.0°C) heat stress conditions. Cutaneous vascular conductance (CVC) and sweat rate were measured continuously at four forearm skin sites perfused with 1) lactated Ringer's solution (Control), 2) 10 mmol L-NAME [inhibits nitric oxide synthase (NOS)], 3) 10 mmol Ketorolac [inhibits cyclooxygenase (COX)], or 4) 4 mmol theophylline (THEO; inhibits adenosine receptors). Relative to pre-IHG levels with Control, NOS inhibition attenuated the metaboreceptor-mediated increase in sweating under LHS and HHS ( P  ≤ 0.05), albeit the attenuation was greater under LHS ( P  ≤ 0.05). In addition, a reduction from baseline was observed with THEO under LHS during OCC ( P  ≤ 0.05), but not HHS (both P  > 0.05). In contrast, CVC was lower than Control with L-NAME during OCC in HHS ( P  ≤ 0.05), but not LHS ( P  > 0.05). We show that metaboreceptor activation modulates CVC via the stimulation of NOS and adenosine receptors, whereas NOS, but not COX or adenosine receptors, contributes to sweating at all levels of heating. © 2017 The Authors. Physiological Reports published by Wiley Periodicals, Inc. on behalf of The Physiological Society and the American Physiological Society.

  20. Sweat osmolarity shows intra-animal regional variation in the horse.

    PubMed

    Potts, Samantha; Thatcher, Rhys; Jones, Arwel W; Warren, Lori K; Tenbroeck, Saundra H; Nottage, Florence; McEwan, Neil R

    2015-10-01

    Sweating is important in regulating body temperature but can be a source of loss of both fluids and electrolytes. Although the process has been studied in horses, the variation in sweat osmolarity across the body has not. This work describes an investigation to determine if there is regional variation in the osmolarity of sweat across different anatomical regions of the horse. Ten horses were used in the study and were animals either stabled for riding lessons or had livery on-site. Sweat samples were collected from five regions on each horse following exercise and the osmolarity measurements were made using an Osmomat 030 (Gonotec, Berlin, Germany). Values were analysed by paired t-tests and analysis of variance. Samples from the back and ears had statistically (P < 0.05) lower osmolarity values than those seen for the neck and forelimb, with thigh values intermediate between the other two sets of values. Previous studies have used osmolarity values based on the sweat collected from the horse's back. The current work demonstrates that these values are probably an underestimation of electrolyte loss, which may have implications for the composition and administration of rehydration compounds. © 2015 ESVD and ACVD.

  1. Design of wearable hybrid generator for harvesting heat energy from human body depending on physiological activity

    NASA Astrophysics Data System (ADS)

    Kim, Myoung-Soo; Kim, Min-Ki; Kim, Kyongtae; Kim, Yong-Jun

    2017-09-01

    We developed a prototype of a wearable hybrid generator (WHG) that is used for harvesting the heat energy of the human body. This WHG is constructed by integrating a thermoelectric generator (TEG) in a circular mesh polyester knit fabric, circular-shaped pyroelectric generator (PEG), and quick sweat-pickup/dry-fabric. The fabric packaging enables the TEG part of the WHG to generate energy steadily while maintaining a temperature difference in extreme temperature environments. Moreover, when the body sweats, the evaporation heat of the sweat leads to thermal fluctuations in the WHG. This phenomenon further leads to an increase in the output power of the WHG. These characteristics of the WHG make it possible to produce electrical energy steadily without reduction in the conversion efficiency, as both TEG and PEG use the same energy source of the human skin and the ambient temperature. Under a temperature difference of ˜6.5 °C and temperature change rate of ˜0.62 °C s-1, the output power and output power density of the WHG, respectively, are ˜4.5 nW and ˜1.5 μW m-2. Our hybrid approach will provide a framework to enhance the output power of the wearable generators that harvest heat energy from human body in various environments.

  2. Treatment of TNT red water by layer melt crystallization.

    PubMed

    Jo, Jeong-Hyeon; Ernest, Takyi; Kim, Kwang-Joo

    2014-09-15

    Treatment of the red water, which is wastewater of 2,4,6- trinitrotoluene (TNT) manufacturing process has been explored using ice crystallization. This study focuses on the formation of ice crystals from the red water in a layer crystallizer under various operating conditions. Among the parameters which affect layer crystallization, attention was given to cooling rate, cooling temperature, sweating rate and concentration of the red water. The study highlights the effect of subcooling and growth rate on purity of the ice crystalline layers produced. After sweating, the COD value of crystalline ice layer was significantly reduced from 10,000 mg/L to below 20mg/L. Most organic contaminants were removed in sweating fractions of 0.5. Eventually, the red water was treated by layer crystallization combined with the sweating process. Copyright © 2014 Elsevier B.V. All rights reserved.

  3. Ectodermal dysplasia

    MedlinePlus

    ... fever, because the skin cannot sweat and control temperature properly. Affected adults are unable to tolerate a ... need special measures to keep a normal body temperature. Depending on which genes are affected, other symptoms ...

  4. Core Temperature and Sweat Responses in Professional Women's Tennis Players During Tournament Play in the Heat

    PubMed Central

    Tippet, Melissa L.; Stofan, John R.; Lacambra, Magie; Horswill, Craig A.

    2011-01-01

    Abstract Context: Tennis is often played in hot, humid environments, intensifying the thermoregulatory strain placed on the athletes. As a safety measure, some tennis organizations allow for a 10-minute break in play between the second and third sets when environmental conditions are extreme. However, the actual effect of these breaks in reducing core temperature is unknown. Objective: To determine change in core temperature after a 10-minute break in play and assess fluid balance in professional female tennis players during tournament matches in the heat. Design: Cross-sectional study. Setting: A Women's Tennis Association Tour–sanctioned outdoor tournament on hard courts under hot conditions (30.3°C ± 2.3°C). Patients or Other Participants: Seven professional tennis players. Main Outcome Measure(s): Change in core temperature after a 10-minute break in tournament play, fluid intake, and sweat losses during match play. Results: Core temperature was reduced from 38.92°C to 38.67°C (change of −0.25°C ± 0.20°C) when a break was taken (P  =  .02). Mean sweat rate during match play was 2.0 ± 0.5 L/h. During that time, mean fluid intake was 1.5 ± 0.5 L/h, resulting in a 1.2% ± 1.0% reduction in body mass. Conclusions: Female professional tennis players are subjected to high heat loads during match play in hot environments. However, a 10-minute break in play decreased core temperature in 6 of 7 players by an average of 0.25°C, indicating that the break provides practical benefits in the field. Furthermore, although mean sweat rate in this group of female tennis players was high, most athletes were still able to minimize mass loss to less than 2% of their prematch weight. PMID:21214351

  5. Occupational Heat Stress Impacts on Health and Productivity in a Steel Industry in Southern India.

    PubMed

    Krishnamurthy, Manikandan; Ramalingam, Paramesh; Perumal, Kumaravel; Kamalakannan, Latha Perumal; Chinnadurai, Jeremiah; Shanmugam, Rekha; Srinivasan, Krishnan; Venugopal, Vidhya

    2017-03-01

    Workers laboring in steel industries in tropical settings with high ambient temperatures are subjected to thermally stressful environments that can create well-known risks of heat-related illnesses and limit workers' productivity. A cross-sectional study undertaken in a steel industry in a city nicknamed "Steel City" in Southern India assessed thermal stress by wet bulb globe temperature (WBGT) and level of dehydration from urine color and urine specific gravity. A structured questionnaire captured self-reported heat-related health symptoms of workers. Some 90% WBGT measurements were higher than recommended threshold limit values (27.2-41.7°C) for heavy and moderate workloads and radiational heat from processes were very high in blooming-mill/coke-oven (67.6°C globe temperature). Widespread heat-related health concerns were prevalent among workers, including excessive sweating, fatigue, and tiredness reported by 50% workers. Productivity loss was significantly reported high in workers with direct heat exposures compared to those with indirect heat exposures (χ 2  = 26.1258, degrees of freedom = 1, p  < 0.001). Change in urine color was 7.4 times higher among workers exposed to WBGTs above threshold limit values (TLVs). Preliminary evidence shows that high heat exposures and heavy workload adversely affect the workers' health and reduce their work capacities. Health and productivity risks in developing tropical country work settings can be further aggravated by the predicted temperature rise due to climate change, without appropriate interventions. Apart from industries enhancing welfare facilities and designing control interventions, further physiological studies with a seasonal approach and interventional studies are needed to strengthen evidence for developing comprehensive policies to protect workers employed in high heat industries.

  6. Development of emotional sweating in the newborn infant.

    PubMed

    Harpin, V A; Rutter, N

    1982-09-01

    Sweating from the palm and sole occurs independently of ambient temperature but is influenced by emotional factors. It thus provides a useful objective measure of emotional state. The development of this emotional sweating in the newborn was investigated by measuring palmar water loss and relating it to the infant's state of arousal. Although 433 individual measurements were made on 124 babies of gestational age 25 to 41 weeks and postnatal age 15 hours to 9 weeks. Palmar water loss was also recorded continuously in 22 infants undergoing heel prick for routine blood sampling. In babies of 37 weeks' gestation or more, there was a clear relationship between palmar water loss and arousal from the day of birth, and by the third week levels on vigorous crying were comparable with those of an anxious adult. Less mature babies did not show emotional sweating at birth; it was first seen at the equivalent of 36 to 37 weeks' gestation regardless of maturity. Continuous recordings confirmed the cross-sectional data and illustrated the abrupt nature of the response. Emotional sweating could be a useful tool for the assessment of emotional state of the newborn.

  7. Pulsed direct and constant direct currents in the pilocarpine iontophoresis sweat chloride test.

    PubMed

    Gomez, Carla Cristina Souza; Servidoni, Maria de Fatima; Marson, Fernando Augusto de Lima; Canavezi, Paulo Jose Coelho; Vinagre, Adriana Mendes; Costa, Eduardo Tavares; Ribeiro, Antonio Fernando; Ribeiro, Maria Angela Gonçalves de Oliveira; Toro, Adyleia Aparecida Dalbo Contrera; Pavan, Celia Regina; Rondon, Michelle Vivine Sá Dos Santos; Lorena, Sonia Leticia Silva; Vieria, Francisco Ubaldi; Ribeiro, Jose Dirceu

    2014-12-13

    The classic sweat test (CST) is the golden standard for cystic fibrosis (CF) diagnosis. Then, our aim was compare the production and volume of sweat, and side effects caused by pulsed direct current (PDC) and constant direct current (CDC). To determine the optimal stimulation time (ST) for the sweat collection. To verify the PDC as CF diagnosis option. Prospective study with cross-sectional experimental intervention. Experiment 1 (right arm): PDC and CDC. ST at 10 min and sweat collected at 30 min. Currents of 0.5; 0.75; 1.0 and 1.5 mA and frequencies of 0, 200, 1,000 and 5,000 Hz applied. Experiment 2 (left arm): current of 1.0 mA, ST at 5 and 10 min and sweat collected at 15 and 30 min with frequencies of 0; 200; 1,000 and 5,000 Hz applied Experiments 1 and 2 were performed with current density (CD) from 0.07 to 0.21 mA/cm2. Experiment 3: PDC was used in typical CF patients with two CFTR mutations screened and or with CF diagnosis by rectal biopsy and patients with atypical CF. 48 subjects (79.16% female) with average of 29.54 ± 8.87 years old were enrolled. There was no statistical difference between the interaction of frequency and current in the sweat weight (p = 0.7488). Individually, positive association was achieved between weight sweat and stimulation frequency (p = 0.0088); and current (p = 0.0025). The sweat production was higher for 10 min of stimulation (p = 0.0023). The sweat collection was better for 30 min (p = 0.0019). The skin impedance was not influenced by ST and sweat collection (p > 0.05). The current frequency was inversely associated with the skin impedance (p < 0.0001). The skin temperature measured before stimulation was higher than after (p < 0.0001). In Experiment 3 (29 subjects) the PDC showed better kappa index compared to CDC (0.9218 versus 0.5205, respectively). The performance of the CST with CDC and PDC with CD of 0.14 to 0.21 mA/cm2 showed efficacy in steps of stimulation and collection of sweat, without side effects. The optimal stimulation time and sweat collection were, respectively, 10 and 30 min.

  8. The development and initial validation of a virtual dripping sweat rate and a clothing wetness ratio for use in predictive heat strain models.

    PubMed

    Kubota, H; Kuwabara, K; Hamada, Y

    2014-08-01

    This paper applies the heat balance equation (HBE) for clothed subjects as a linear function of mean skin temperature (t sk ) by a new sweating efficiency (η sw ) and an approximation for the thermoregulatory sweat rate. The equation predicting t sk in steady state conditions was derived as the solution of the HBE and used for a predictive heat strain scale. The heat loss from the wet clothing (WCL) area was identified with a new variable of 'virtual dripping sweat rate VDSR' (S wdr ). This is a subject's un-evaporated sweat rate in dry clothing from the regional sweat rate exceeding the maximum evaporative capacity, and adds the moisture to the clothing, reducing the intrinsic clothing insulation. The S wdr allowed a mass balance analysis of the wet clothing area identified as clothing wetness (w cl ). The w cl was derived by combining the HBE at the WCL surface from which the evaporation rate and skin heat loss from WCL region are given. Experimental results on eight young male subjects wearing typical summer clothing, T-shirt and trousers verified the model for predicting t sk with WCL thermal resistance (R cl,w ) identified as 25 % of dry clothing (R cl,d ).

  9. The development and initial validation of a virtual dripping sweat rate and a clothing wetness ratio for use in predictive heat strain models

    NASA Astrophysics Data System (ADS)

    Kubota, H.; Kuwabara, K.; Hamada, Y.

    2014-08-01

    This paper applies the heat balance equation (HBE) for clothed subjects as a linear function of mean skin temperature ( t sk ) by a new sweating efficiency ( η sw ) and an approximation for the thermoregulatory sweat rate. The equation predicting t sk in steady state conditions was derived as the solution of the HBE and used for a predictive heat strain scale. The heat loss from the wet clothing (WCL) area was identified with a new variable of `virtual dripping sweat rate VDSR' ( S wdr ). This is a subject's un-evaporated sweat rate in dry clothing from the regional sweat rate exceeding the maximum evaporative capacity, and adds the moisture to the clothing, reducing the intrinsic clothing insulation. The S wdr allowed a mass balance analysis of the wet clothing area identified as clothing wetness ( w cl ). The w cl was derived by combining the HBE at the WCL surface from which the evaporation rate and skin heat loss from WCL region are given. Experimental results on eight young male subjects wearing typical summer clothing, T-shirt and trousers verified the model for predicting t sk with WCL thermal resistance ( R cl,w ) identified as 25 % of dry clothing ( R cl,d ).

  10. The effect of two kinds of T-shirts on physiological and psychological thermal responses during exercise and recovery.

    PubMed

    Brazaitis, Marius; Kamandulis, Sigitas; Skurvydas, Albertas; Daniusevičiūtė, Laura

    2010-12-01

    The aim of this study was to investigate the physiological and psychological responses during and after high-intensity exercise in a warm and humid environment in subjects wearing shirts of different fabrics. Eight healthy men exercised on two separate occasions, in random order, wearing two types of long-sleeve T-shirt: one made of polyester (PES) and the other of cotton fabric (CT). They performed three 20 min exercise bouts, with 5 min rest between each, and then rested in a chair for 60 min to recover. The ambient temperature was 25 °C and relative humidity was 60%. The exercise comprised of treadmill running at 8 km/h at 1° grade. Rectal temperature, skin temperatures at eight sites, heart rate, T-shirt mass and ratings of thermal, clothing wettedness, and shivering/sweating sensation were measured before the experiment, during the 5 min rest period after each exercise bout, and during recovery. Nude body mass was measured before the experiment and during recovery. The physiological stress index showed that the exercise produced a state of very high heat stress. Compared with exercise wearing the CT shirt, exercise wearing the PES fabric produced a greater sweating efficiency and less clothing regain (i.e., less sweat retention), but thermophysiological and subjective sensations during the intermittent high-intensity exercise were similar for both fabrics. However, skin temperature returned to the pre-exercise level faster, and the thermal and rating of shivering/sweating sensation were lower after exercise in the warm and humid environment in subjects wearing PES than when wearing the more traditional CT fabric. Copyright © 2010 Elsevier Ltd. All rights reserved.

  11. Influence of various environmental parameters on sweat gland activity.

    PubMed

    McMullen, Roger L; Gillece, Tim; Lu, Guojin; Laura, Donna; Chen, Susan

    2013-01-01

    The choice of environmental conditions when conducting antiperspirant studies greatly affects the quantity of sweat output. Our initial goal in this work was to develop an in-house procedure to test the efficacy of antiperspirant products using replica techniques in combination with image analysis. To ameliorate the skin replica method, we conducted rheological studies using dynamic mechanical analysis of the replica formulation. In terms of sweat output quantification, our preliminary results revealed a considerable amount of variation using the replica technique, leading us to conduct more fundamental studies of the factors that influence sweating behavior and how to best design the experimental strategy. In accordance with the FDA's protocol for antiperspirant testing, we carried out gravimetric analyses of axillae sweating under a variety of environmental conditions including temperature and humidity control. Subjects were first acclimatized in an environmentally controlled room for 30 min, and then placed in a sauna for an additional 30 or 45 min, depending on which test we administered. In Test 1 (30 min total in the sauna), the first 10 min in the sauna was another equilibration period, followed by a 20 min sweat production stage. We monitored axillae sweating during the last 20 min in the sauna by gravimetric analysis. At time (t) = 30 min in the sauna, skin replicas were taken and later analyzed using imaging and image analysis techniques. Test 1 was carried out on over 25 subjects, both male and female, from various racial backgrounds. In Test 2, subjects spent 45 min in the sauna after the initial 30-min period in the environmental room. During the 45 min, we obtained gravimetric readings of absorbent pads placed in the axillae. We conducted studies at various temperature and relative humidity settings. We also studied the influence of several external parameters on sudoriferous activity. Test 2 was a range-finding experiment on two subjects to determine the optimized environmental conditions for the hot room procedure. In addition to the replica and gravimetric techniques, we also measured flux density to determine the onset of firing of sweat glands to ensure that our environmental preconditioning step (30 min in the environmental room) brought subjects to the point that their sweat glands were activated. Although flux density measurements are usually carried out to determine transepidermal water loss (TEWL), we found that they can be equally useful for monitoring the onset of sweat production. Thermal infrared imaging experiments were also carried out allowing us to generate full-body images of subjects containing anatomical thermal distribution data with high accuracy. Overall, we conclude that our in-house hot room procedure offers much potential as an effective and cost-efficient screening tool for narrowing copious antiperspirant formulations to a select few for expensive clinical evaluation.

  12. Spatial temporal analysis of urban heat hazard in Tangerang City

    NASA Astrophysics Data System (ADS)

    Wibowo, Adi; Kuswantoro; Ardiansyah; Rustanto, Andry; Putut Ash Shidiq, Iqbal

    2016-11-01

    Urban heat is a natural phenomenon which might caused by human activities. The human activities were represented by various types of land-use such as urban and non-urban area. The aim of this study is to identify the urban heat behavior in Tangerang City as it might threats the urban environment. This study used three types of remote sensing data namely, Landsat TM, Landsat ETM+ and Landsat OLI-TIRS, to capture the urban heat behavior and to analysis the urban heat signature of Tangerang City in 2001, 2012, 2013, 2014, 2015 and 2016. The result showed that urban heat signature change dynamically each month based on the sun radiation. The urban heat island covered only small part of Tangerang City in 2001, but it was significantly increased and reached 50% of the area in 2012. Based on the result on urban heat signature, the threshold for threatening condition is 30 oC which recognized from land surface temperature (LST). The effective temperature (ET) index explains that condition as warm, uncomfortable, increase stress due to sweating and blood flow and may causing cardiovascular disorder.

  13. Contact skin temperature measurements and associated effects of obstructing local sweat evaporation during mild exercise-induced heat stress.

    PubMed

    MacRae, Braid A; Rossi, Rene Michel; Psikuta, Agnes; Spengler, Christina M; Annaheim, Simon

    2018-06-05

    Locally increasing evaporative resistance is one mechanism by which contact skin temperature (Tsk) sensors and their attachments may disturb the temperature of the skin site being measured. We aimed to determine the extent to which an obstruction of evaporation affects local Tsk during exercise-induced sweating and how this compares to the Tsk measured using a conventional contact Tsk sensor. Twelve adult males each completed one experimental session (~24°C, ~46 % relative humidity; RH) involving seated rest and exercise (cycle ergometer). Air velocity was ~0.5 m·s-1 during rest and ~1 m·s-1 during exercise. Tsk of the right posterolateral forearm was measured using fine-wire thermocouples (0.125 mm diameter; chosen for minimal sensor-related disturbance) under two concurrent experimental conditions: uncovered or directly covered by a moisture-impermeable matte-black aluminium foil (thickness 0.08 mm, area 15 mm x 22 mm). The adjacent Tsk was also measured using an iButton attached with a nonwoven medical tape. Changes in next-to-skin absolute vapour pressure were used to estimate the onset of sweating. During exercise, covered thermocouple temperatures were consistently warmer than those uncovered. These differences were small before the onset of sweating (0.1°C, p=0.16), but increased thereafter (0.6 and 1.0°C by minutes 15 and 30 of exercise, respectively; p≤0.03). For change scores from baseline rest, the iButton-measured Tsk was as much as 0.7°C warmer than uncovered and -0.4°C cooler than covered thermocouples during sweating, but differences were not statistically supported and with wide 95% limits of agreement (up to ±3.1°C). When delineated, a small obstruction of evaporation itself caused an overestimation of Tsk during exercise although, while demonstrable, these effects were less clear in the context of using a conventional contact Tsk sensor and attachment. © 2018 Institute of Physics and Engineering in Medicine.

  14. Sweat Sodium, Potassium, and Chloride Concentrations Analyzed Same Day as Collection Versus After 7 Days Storage in a Range of Temperatures.

    PubMed

    Baker, Lindsay B; Barnes, Kelly A; Sopeña, Bridget C; Nuccio, Ryan P; Reimel, Adam J; Ungaro, Corey T

    2018-05-22

    The purpose of this study was to determine the effect of storage temperature on sodium ([Na + ]), potassium ([K + ]), and chloride ([Cl - ]) concentrations of sweat samples analyzed 7 days after collection. Using the absorbent patch technique, 845 sweat samples were collected from 39 subjects (32 ± 7 years, 72.9 ± 10.5 kg) during exercise. On the same day as collection (PRESTORAGE), 609 samples were analyzed for [Na + ], [Cl - ], and [K + ] by ion chromatography (IC) and 236 samples were analyzed for [Na + ] using a compact ion-selective electrode (ISE). Samples were stored at one of the four conditions: -20 °C (IC, n = 138; ISE, n = 60), 8 °C (IC, n = 144; ISE, n = 59), 23 °C (IC, n = 159; ISE, n = 59), or alternating between 8 °C and 23 °C (IC, n = 168; ISE, n = 58). After 7 days in storage (POSTSTORAGE), samples were reanalyzed using the same technique as PRESTORAGE. PRESTORAGE sweat electrolyte concentrations were highly related to that of POSTSTORAGE (intraclass correlation coefficient: .945-.989, p < .001). Mean differences (95% confidence intervals) between PRESTORAGE and POSTSTORAGE were statistically, but not practically, significant for most comparisons: IC [Na + ]: -0.5(0.9) to -2.1(0.9) mmol/L; IC [K + ]: -0.1(0.1) to -0.2(0.1) mmol/L; IC [Cl - ]: -0.4(1.4) to -1.3(1.3) mmol/L; ISE [Na + ]: -2.0(1.1) to 1.3(1.1) mmol/L. Based on typical error of measurement results, 95% of the time PRESTORAGE and POSTSTORAGE sweat [Na + ], [K + ], and [Cl - ] by IC analysis fell within ±7-9, ±0.6-0.7, and ±9-13 mmol/L, respectively, while sweat [Na + ] by ISE was ±6 mmol/L. All conditions produced high reliability and acceptable levels of agreement in electrolyte concentrations of sweat samples analyzed on the day of collection versus after 7 days in storage.

  15. Electrical double layer modulation of hybrid room temperature ionic liquid/aqueous buffer interface for enhanced sweat based biosensing.

    PubMed

    Jagannath, Badrinath; Muthukumar, Sriram; Prasad, Shalini

    2018-08-03

    We have investigated the role of kosmotropic anionic moieties and chaotropic cationic moieties of room temperature hydrophilic ionic liquids in enhancing the biosensing performance of affinity based immunochemical biosensors in human sweat. Two ionic liquids, 1-butyl-3-methylimidazolium tetrafluoroborate (BMIM[BF 4 ]) and choline dihydrogen phosphate (Choline[DHP]) were investigated in this study with Choline[DHP] being more kosmotropic in nature having a more protein stabilizing effect based on the hofmeister series. Non-faradaic interfacial charge transfer has been employed as the mechanism for evaluating the formation and the biosensing of capture probe antibodies in room temperature ionic liquids (RTILs)/aqueous human sweat interface. The charge of the ionic moieties were utilized to form compact electrical double layers around the antibodies for enhancing the stability of the antibody capture probes, which was evaluated through zeta potential measurements. The zeta potential measurements indicated stability of antibodies due to electrostatic repulsion of the RTIL charged moieties encompassing the antibodies, thus preventing any aggregation. Here, we report for the first time of non-faradaic electrochemical impedance spectroscopy equivalent circuit model analysis for analyzing and interpreting affinity based biosensing at hybrid electrode/ionic liquid-aqueous sweat buffer interface guided by the choice of the ionic liquid. Interleukin-6 (IL-6) and cortisol two commonly occurring biomarkers in human sweat were evaluated using this method. The limit of detection (LOD) obtained using both ionic liquids for IL-6 was 0.2 pg mL -1 with cross-reactivity studies indicating better performance of IL-6 detection using Choline[DHP] and no response to cross-reactive molecule. The LOD of 0.1 ng/mL was achieved for cortisol and the cross-reactivity studies indicated that cortisol antibody in BMIM[BF 4 ] did not show any signal response to cross-reactive molecules. Furthermore, improved sensitivity and LOD was achieved using ionic liquids as compared to capture probes in aqueous buffer. Copyright © 2018 Elsevier B.V. All rights reserved.

  16. An inhomogeneous thermal block model of man for the electromagnetic environment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chatterjee, I.; Gandhi, O.P.

    An inhomogeneous four layer block thermal model of a human body, composed of 476 electromagnetic-sensitive cubical cells has been developed to study the effects of electromagnetic radiation. Varying tissue properties defined by thermal conductivity, specific heat, blood flow rate and metabolic heat production are accounted for by equations. Peripheral cell temperature is weight-averaged for total cell volume and is thereby higher than actual skin temperature. During electromagnetic field exposure, additional factors considered are increased blood flow rate caused by vasodilation and sweat-induced heat loss. Hot spots have been located in the model and numerical results are presented. Subjected to planemore » wave iradiation, the model's sweating and insensible perspiration cease and all temperatures converge. Testing during electromagnetic hyperthemia shows all temperature body parts to increase approximately at the same rate.« less

  17. Does attenuated skin blood flow lower sweat rate and the critical environmental limit for heat balance during severe heat exposure?

    PubMed

    Cramer, Matthew N; Gagnon, Daniel; Crandall, Craig G; Jay, Ollie

    2017-02-01

    What is the central question of this study? Does attenuated skin blood flow diminish sweating and reduce the critical environmental limit for heat balance, which indicates maximal heat loss potential, during severe heat stress? What is the main finding and its importance? Isosmotic hypovolaemia attenuated skin blood flow by ∼20% but did not result in different sweating rates, mean skin temperatures or critical environmental limits for heat balance compared with control and volume-infusion treatments, suggesting that the lower levels of skin blood flow commonly observed in aged and diseased populations may not diminish maximal whole-body heat dissipation. Attenuated skin blood flow (SkBF) is often assumed to impair core temperature (T c ) regulation. Profound pharmacologically induced reductions in SkBF (∼85%) lead to impaired sweating, but whether the smaller attenuations in SkBF (∼20%) more often associated with ageing and certain diseases lead to decrements in sweating and maximal heat loss potential is unknown. Seven healthy men (28 ± 4 years old) completed a 30 min equilibration period at 41°C and a vapour pressure (P a ) of 2.57 kPa followed by incremental steps in P a of 0.17 kPa every 6 min to 5.95 kPa. Differences in heat loss potential were assessed by identifying the critical vapour pressure (P crit ) at which an upward inflection in T c occurred. The following three separate treatments elicited changes in plasma volume to achieve three distinct levels of SkBF: control (CON); diuretic-induced isosmotic dehydration to lower SkBF (DEH); and continuous saline infusion to maintain SkBF (SAL). The T c , mean skin temperature (T sk ), heart rate, mean laser-Doppler flux (forearm and thigh; LDF mean ), mean local sweat rate (forearm and thigh; LSR mean ) and metabolic rate were measured. In DEH, a 14.2 ± 5.7% lower plasma volume resulted in a ∼20% lower LDF mean in perfusion units (PU) (DEH, 139 ± 23 PU; CON, 176 ± 22 PU; and SAL, 186 ± 22 PU; P = 0.034). However, LSR mean and whole-body sweat losses were unaffected by treatment throughout (P > 0.482). The P crit for T c was similar between treatments (CON, 5.05 ± 0.30 kPa; DEH, 4.93 ± 0.16 kPa; and SAL, 5.12 ± 0.10 kPa; P = 0.166). Furthermore, no differences were observed in the skin-air temperature gradient, metabolic rate or changes in T c (P > 0.197). In conclusion, a ∼20% reduction in SkBF alters neither sweat rate nor the upper limit for heat loss from the skin during non-encapsulated passive heat stress. © 2016 The Authors. Experimental Physiology © 2016 The Physiological Society.

  18. [Sports and extreme conditions. Cardiovascular incidence in long term exertion and extreme temperatures (heat, cold)].

    PubMed

    Melin, B; Savourey, G

    2001-06-30

    During ultra-endurance exercise, both increase in body temperature and dehydration due to sweat losses, lead to a decrease in central blood volume. The heart rate drift allows maintaining appropriate cardiac output, in order to satisfy both muscle perfusion and heat transfer requirements by increasing skin blood flow. The resulting dehydration can impair thermal regulation and increase the risks of serious accidents as heat stroke. Endurance events, lasting more than 8 hours, result in large sweat sodium chloride losses. Thus, ingestion of large amounts of water with poor salt intake can induce symptomatic hyponatremia (plasma sodium < 130 mEq/L) which is also a serious accident. Heat environment increases the thermal constraint and when the air humidity is high, evaporation of sweat is compromise. Thus, thermal stress becomes uncompensable which increases the risk of cardiovascular collapse. Cold exposure induces physiological responses to maintain internal temperature by both limiting thermal losses and increasing metabolic heat production. Cold can induce accidental hypothermia and local frost-bites; moreover, it increases the risk of arrhythmia during exercise. Some guidelines (cardiovascular fitness, water and electrolyte intakes, protective clothing) are given for each extreme condition.

  19. Active recovery attenuates the fall in sweat rate but not cutaneous vascular conductance after supine exercise.

    PubMed

    Wilson, Thad E; Carter, Robert; Cutler, Michael J; Cui, Jian; Smith, Michael L; Crandall, Craig G

    2004-02-01

    The purpose of this study was to identify whether baroreceptor unloading was responsible for less efficient heat loss responses (i.e., skin blood flow and sweat rate) previously reported during inactive compared with active recovery after upright cycle exercise (Carter R III, Wilson TE, Watenpaugh DE, Smith ML, and Crandall CG. J Appl Physiol 93: 1918-1929, 2002). Eight healthy adults performed two 15-min bouts of supine cycle exercise followed by inactive or active (no-load pedaling) supine recovery. Core temperature (T(core)), mean skin temperature (T(sk)), heart rate, mean arterial blood pressure (MAP), thoracic impedance, central venous pressure (n = 4), cutaneous vascular conductance (CVC; laser-Doppler flux/MAP expressed as percentage of maximal vasodilation), and sweat rate were measured throughout exercise and during 5 min of recovery. Exercise bouts were similar in power output, heart rate, T(core), and T(sk). Baroreceptor loading and thermal status were similar during trials because MAP (90 +/- 4, 88 +/- 4 mmHg), thoracic impedance (29 +/- 1, 28 +/- 2 Omega), central venous pressure (5 +/- 1, 4 +/- 1 mmHg), T(core) (37.5 +/- 0.1, 37.5 +/- 0.1 degrees C), and T(sk) (34.1 +/- 0.3, 34.2 +/- 0.2 degrees C) were not significantly different at 3 min of recovery between active and inactive recoveries, respectively; all P > 0.05. At 3 min of recovery, chest CVC was not significantly different between active (25 +/- 6% of maximum) and inactive (28 +/- 6% of maximum; P > 0.05) recovery. In contrast, at this time point, chest sweat rate was higher during active (0.45 +/- 0.16 mg.cm(-2).min(-1)) compared with inactive (0.34 +/- 0.19 mg.cm(-2).min(-1); P < 0.05) recovery. After exercise CVC and sweat rate are differentially controlled, with CVC being primarily influenced by baroreceptor loading status while sweat rate is influenced by other factors.

  20. Thermoregulatory demands of elite professional America's Cup yacht racing.

    PubMed

    Neville, V; Gant, N; Folland, J P

    2010-06-01

    America's Cup yacht racing predominantly occurs during the summer months under hot and humid conditions, with athletes exposed to the environment for prolonged periods, and yet the thermoregulatory responses to competitive sailing are largely unappreciated. This study aimed to assess the thermoregulatory responses to elite professional big-boat yacht racing, according to crew position and upwind and downwind sailing. Intestinal (T(core)) and skin temperature, fluid balance and regional sweat compositions were measured in two America's Cup crews (n=32) during 100 min of racing. The environmental conditions were as follows: 32 degrees C, 52% RH and 5 m/s wind speed. Subjective race intensity was moderate. Bowmen recorded the greatest elevation in the heart rate (184 +/- 10 beats/min) and T(core) (39.2 degrees C, P<0.01). Both heart rate and T(core) were higher during downwind sailing (P<0.001). Regional skin temperatures were significantly different according to site (P=0.05), with tibia being the lowest (33.3 +/- 1.2 degrees C). The mean sweat loss during racing was 1.34 +/- 0.58 L/h (range: 0.44-2.40 L/h), with bowmen experiencing the greatest loss of sweat (3.7 +/- 0.9% of body mass). The mean fluid intake was highly correlated to sweat loss (r=0.74, P<0.001), with 72 +/- 41% of sweat losses replaced. The mean sodium concentration of sweat was 27.2 +/- 9.2 mmol/L (range: 12.0-43.5 mmol/L) and the total NaCl loss during sailing was 3.8 +/- 2.4 g (range 0.7-10.0 g). America's Cup sailing is a demanding sport that presents considerable challenges to thermoregulation, fluid and electrolyte balance. Certain crew roles (bowmen) present an increased risk of developing exertional heat illness, and for the majority of crew downwind sailing results in greater thermal strain than upwind sailing - which may have implications for clothing selection and boat design.

  1. Does attenuated skin blood flow lower sweat rate and the critical environmental limit for heat balance during severe heat exposure?

    PubMed Central

    Cramer, Matthew N.; Gagnon, Daniel; Crandall, Craig G.; Jay, Ollie

    2016-01-01

    Attenuated skin blood flow (SkBF) is often assumed to impair core temperature (Tc) regulation. Profound pharmacologically-induced reductions in SkBF (~85%) lead to impaired sweating but whether the smaller attenuations in SkBF (~20%) more associated with ageing and certain diseases lead to decrements in sweating and maximum heat loss potential is unknown. Seven healthy males (28±4y) completed a 30-min equilibration period at 41°C and a vapour pressure (Pa) of 2.57 kPa followed by incremental steps in Pa of 0.17 kPa every 6-min to 5.95 kPa. Differences in heat loss potential were assessed by identifying the critical vapour pressure (Pcrit) at which an upward inflection in Tc occurred. Three separate treatments elicited changes in plasma volume to achieve three distinct levels of SkBF: control (CON), diuretic-induced iso-osmotic dehydration to lower SkBF (DEH), and continuous saline infusion to maintain SkBF (SAL). Tc, mean skin temperature (Tsk), heart rate, mean laser-Doppler flux (forearm, thigh; LDFmean), mean local sweat rate (forearm, thigh; LSRmean), and metabolic rate were measured. In DEH, a 14.2±5.7% lower plasma volume resulted in a ~20% lower LDFmean (DEH: 139±23, CON: 176±22, SAL: 186±22 PU; P=0.034). However, LSRmean and whole-body sweat losses were unaffected by treatment throughout (P>0.482). Pcrit for Tc was similar between treatments (CON: 5.05±0.30, DEH: 4.93±0.16, SAL: 5.12±0.10 kPa; P=0.166). Further, no differences were observed in the Tsk−Ta gradient, metabolic rate, or changes in Tc (P>0.197). In conclusion, a ~20% reduction in SkBF alters neither sweat rate nor the upper limit for heat loss from the skin during non-encapsulated passive heat stress. PMID:27859929

  2. Assessing the impact of egg sweating on Salmonella Enteritidis penetration into shell eggs.

    PubMed

    Gradl, Janet A; Curtis, Patricia A; Jones, Deana R; Anderson, Kenneth E

    2017-07-01

    Salmonella Enteritidis (SE) prevalence in eggs is a major concern to the egg industry. Some research has shown that egg sweating can increase Salmonella penetration into egg contents when refrigerated eggs are moved to a warmer temperature. This occurs when eggs are tempered before wash, to minimize thermal cracks. The effect of egg sweating on SE penetration into shell eggs over a 6 week storage period at 4°C was assessed. A 2 × 2 factorial of SE inoculation and egg sweating was utilized. Treatments included (SES) nalidixic acid (NA)-resistant SE inoculated and sweated, (SENS) NA-resistant SE inoculated and not sweated, (NSES) buffered peptone water (BPW) inoculated and sweated, and (NSENS) BPW inoculated and not sweated. Eggs were inoculated with 108 SE. Eggs formed condensation for approximately 17 min in a 32°C incubator. Shell rinse, shell emulsion, and egg contents were sampled then enumerated and assessed for prevalence of SE over a 6 wk storage period at 4°C. After wk 1, the SENS shell rinse had higher SE counts (0.32 log10 CFU/mL) than the other 3 treatments, where no SE was enumerated. A significant week by treatment interaction was found for the shell rinse SE detection (P < 0.05). In subsequent weeks, no SE counts were obtained from the egg shell rinse, shell emulsion, or egg contents. The SENS shell rinses had significantly higher SE prevalence than the SES rinses in weeks 1 (100% vs. 34.3%), 2 (57.6% vs. 22.2%), and 3 (38.2% vs. 11.1%) (P < 0.05). In samples from weeks 4, 5, and 6, there was no difference in SE prevalence between SES and SENS. Egg sweating did not increase SE penetration into the shell emulsion across treatment or week (P < 0.05). The decreasing trend of SE prevalence obtained over the study period indicate that refrigeration is effective at inhibiting SE growth. These results indicate that egg sweating occurring under common US egg handling practices is not harmful to egg safety. © 2017 Poultry Science Association Inc.

  3. The Effects of Heat Adaptation on Physiology, Perception and Exercise Performance in the Heat: A Meta-Analysis.

    PubMed

    Tyler, Christopher J; Reeve, Tom; Hodges, Gary J; Cheung, Stephen S

    2016-11-01

    Exercise performance and capacity are impaired in hot, compared to temperate, conditions. Heat adaptation (HA) is one intervention commonly adopted to reduce this impairment because it may induce beneficial exercise performance and physiological and perceptual adaptations. A number of investigations have been conducted on HA but, due to large methodological differences, the effectiveness of different HA regimens remain unclear. (1) To quantify the effect of different HA regimens on exercise performance and the physiological and perceptual responses to subsequent heat exposure. (2) To offer practical HA recommendations and suggestions for future HA research based upon a systematic and quantitative synthesis of the literature. PubMed was searched for original research articles published up to, and including, 16 February 2016 using appropriate first- and second-order search terms. English-language, peer-reviewed, full-text original articles using human participants were reviewed using the four-stage process identified in the PRISMA statement. Data for the following variables were obtained from the manuscripts by at least two of the authors: participant sex, maximal oxygen consumption and age; HA duration, frequency, modality, temperature and humidity; exercise performance and capacity; core and skin temperature; heart rate, stroke volume, cardiac output, skin blood flow, sweat onset temperature, body mass loss, sweat rate, perception of thirst, volitional fluid consumption, plasma volume changes; sweat concentrations of sodium, chloride and potassium; aldosterone, arginine vasopressin, heat shock proteins (Hsp), ratings of perceived exertion (RPE) and thermal sensation. Data were divided into three groups based upon the frequency of the HA regimen. Performance and capacity data were also divided into groups based upon the type of HA used. Hedges' g effect sizes and 95 % confidence intervals were calculated. Correlations were run where appropriate. Ninety-six articles were reviewed. The most common duration was 7-14 days and the most common method of HA was the controlled work-rate approach. HA had a moderately beneficial effect on exercise capacity and performance in the heat irrespective of regimen; however, longer regimens were more effective than shorter approaches. HA had a moderate-to-large beneficial effect on lowering core body temperature before and during exercise, maintaining cardiovascular stability, and improving heat-loss pathways. Data are limited but HA may reduce oxygen consumption during subsequent exercise, improve glycogen sparing, increase the power output at lactate threshold, reduce lactate concentrations during exercise, have a trivial effect on increasing extracellular concentrations of Hsp, and improve perceived ratings of exertion and thermal sensation. HA regimens lasting <14 days induce many beneficial physiological and perceptual adaptations to high ambient temperatures, and improve subsequent exercise performance and capacity in the heat; however, the extent of the adaptations is greatest when HA regimens lasting longer than 14 days are adopted. Large methodological differences in the HA literature mean that there is still uncertainty regarding the magnitude and time course of potential adaptation for a number of physiological and perceptual variables.

  4. Dehydration and heat-related death: sweat lodge syndrome.

    PubMed

    Byard, Roger W; Riches, Karen J

    2005-09-01

    A 37-year-old Caucasian male died of dehydration and heat exposure following a sweat lodge ceremony in outback Australia. The case demonstrates difficulties that may arise in the determination of the cause of death at autopsy due to nonspecific pathologic findings in hyperthermic deaths. There are also a number of features that characterize this particular "sweat lodge syndrome," including prolonged exposure to elevated temperatures in a relatively uncontrolled environment, failure to ensure adequate hydration, failure to appreciate the significance of loss of consciousness, use of ineffective alternative methods of treatment, and delay in seeking appropriate medical care. Unfortunately, the adoption of rituals and practice from other cultures may not be a completely safe undertaking. Participants in this type of activity must be cognizant of the types of medical problems that may arise. Individuals with significant cardiovascular disease, those who are taking certain medications that predispose to hyperthermia, or those who have had large amounts of alcohol should not enter sweat lodges.

  5. Pharmacophysiology of atopic dermatitis.

    PubMed

    Hanifin, J M

    1986-02-01

    Atopic dermatitis is clearly characterized by altered cutaneous physiologic responses. There is a tendency to acral vasoconstriction. Rubbing causes skin pallor and white dermographism. Vascular instability is demonstrated by responses to cholinergic agents, histamine, and nicotinates. Psychophysiologic studies demonstrate exaggerated vasodilator responses to emotional stress with consequent pruritus and scratching. The itch threshold is low, duration is prolonged, and nighttime scratching movements may be frequent or almost continuous. Regardless of the inciting trigger factors, the scratching causes the damage and the severe dermatitis. Thermal as well as emotional stimuli to sweating cause severe itching in AD, yet the concept of a miliaria-type, poral occlusion mechanism remains unproven. Some studies suggest actually increased sweating along with erythema and pruritus during acute flares of AD. The concept of sweat-borne allergens causing skin reactions during sweating is interesting but has never been proven. Studies of sweat responses to pharmacologic agents have produced conflicting data, and attempts to link these responses to Szentivanyi's beta-adrenergic blockade theory are not convincing. The numerous variables of climate, season, sex, age, and habitus affect sweating greatly. Future studies must carefully control for each of these factors before pharmacologically induced sweat responses can be interpreted clearly. A number of lines of evidence suggest involvement of histamine and other mediators in the evolution of erythema, pruritus, and scratching in AD. Flares of the condition have been reproducibly evoked by only two incitants: experimental emotional stress interviews and specific food challenge in selected sensitive individuals. In the latter, increased plasma histamine has been demonstrated, presumably generated by antigen/IgE stimulated degranulation of mast cells in the gut and/or skin. The demonstrated increased histamine releasability of basophils from atopic individuals may be the result of defective cellular regulatory mechanisms. Recent studies have demonstrated increased cyclic AMP-phosphodiesterase activity in leukocytes from atopic individuals. The resultant decreased intracellular cyclic AMP removes an inhibitory factor, which in turn causes net cellular hyperresponsiveness. This effect has been shown to account, at least in part, for increased histamine release from leukocytes of patients with AD. These and other studies focused upon cell functional regulation are providing better understanding of basic biochemical abnormalities and may lead to improved diagnostic and therapeutic approaches in managing atopic disease.

  6. Modelling fire-fighter responses to exercise and asymmetric infrared radiation using a dynamic multi-mode model of human physiology and results from the sweating agile thermal manikin.

    PubMed

    Richards, M G M; Fiala, D

    2004-09-01

    In this study, predicted dynamic physiological responses are compared with wear trials results for firefighter suits: impermeable (A), semi-permeable (B) and permeable (C), and underwear. Wear trials consisted of three rest phases and two moderate work phases, with a frontal infrared (IR) radiation exposure of 500 W/m2 for the last 15 min of each work phase. Simulations were performed by detailed modelling of the experimental boundary conditions, including the inhomogeneous IR radiation combined with clothing properties for still and walking conditions measured using the Sweating Agile thermal Manikin. Accounting for the effect of sweat gland activity suppression with increased skin wettedness, the predicted total moisture loss was insignificantly different (P<0.05) from the wear trial value for suits B and C but was 37% too high for suit A. Predicted evolution of core, mean skin and local skin temperatures agreed well with the wear trial results for all clothing. Root mean square deviations ranged from 0.11 degrees C to 0.26 degrees C for core temperatures and from 0.28 degrees C to 0.38 degrees C for mean skin temperatures, which where typically lower than the experimental error. Transient thermodynamic processes occurring within suit A may account for the delayed/reduced fall in core temperature following exercise.

  7. Contribution of thermal and nonthermal factors to the regulation of body temperature in humans.

    PubMed

    Mekjavic, Igor B; Eiken, Ola

    2006-06-01

    The set point has been used to define the regulated level of body temperature, suggesting that displacements of core temperature from the set point initiate heat production (HP) and heat loss (HL) responses. Human and animal experiments have demonstrated that the responses of sweating and shivering do not coincide at a set point but rather establish a thermoeffector threshold zone. Neurophysiological studies have demonstrated that the sensor-to-effector pathways for HP and HL overlap and, in fact, mutually inhibit each other. This reciprocal inhibition theory, presumably reflecting the manner in which thermal factors contribute to homeothermy in humans, does not incorporate the effect of nonthermal factors on temperature regulation. The present review examines the actions of these nonthermal factors within the context of neuronal models of temperature regulation, suggesting that examination of these factors may provide further insights into the nature of temperature regulation. It is concluded that, although there is no evidence to doubt the existence of the HP and HL pathways reciprocally inhibiting one another, it appears that such a mechanism is of little consequence when comparing the effects of nonthermal factors on the thermoregulatory system, since most of these factors seem to exert their influence in the region after the reciprocal cross-inhibition. At any given moment, both thermal and several nonthermal factors will be acting on the thermoregulatory system. It may, therefore, not be appropriate to dismiss the contribution of either when discussing the regulation of body temperature in humans.

  8. Temperature responses of exercizing dogs to infusion of electrolytes

    NASA Technical Reports Server (NTRS)

    Greenleaf, J. E.; Kozlowski, S.; Nazar, K.; Kaciuba-Uscilko, H.; Brzezinska, Z.

    1974-01-01

    The effect of infusions with solutions of various ionic and osmotic composition on exercise temperature responses was studied in dogs who do not regulate their temperature by sweating. The results suggest an association between plasma Na+ and Ca++ level within the normal physiological range and the control of body temperature during exercise.

  9. Implications of Advanced Crew Escape Suit Transpiration for the Orion Program

    NASA Technical Reports Server (NTRS)

    Bue, Grant; Kuznetz, Lawrence

    2009-01-01

    Human testing was conducted to more fully characterize the integrated performance of the Advanced Crew Escape Suit (ACES) with liquid cooling provide by an Individual Cooling Unit (ICU) across a broad range of environmental conditions and metabolic rates. Together with a correlation for the ACES Liquid Cooling Garment as a function of inlet temperature, metabolic rate, and crew size, a reasonably conservative correlation for core temperature was achieved for the human thermal model applied to the ACES with ICU cooling. A key observation for this correlation was accounting for transpiration of evaporated sweat through the Gortex(Registered TradeMark) liner of the ACES indicated by as much as 0.6 lbm of sweat evaporated over the course of the 1 hour test profile, most of which could not be attributed to respiration or head sweat evaporation of the crew. Historically it has been assumed that transpiration was not an important design feature of the ACES suit. The correlated human thermal model will show transpiration to be highly useful in hot survival situations for the Orion Program when adequate liquid cooling is not available.

  10. Effects of age, sex, sweat rate and environmental conditions on heart rate and perceived exertion in indoor cycling.

    PubMed

    Barbado, Carlos; Vicente-Campos, Davinia; Lopez-Chicharro, José

    2017-05-05

    Indoor cycling sessions are usually guided by heart rate (HR) and rating of perceived exertion (RPE). This study was designed to examine the effects of sex, age, previous experience, use of a HR monitor, estimated sweat rate and room temperature and humidity increases on HR and RPE during indoor cycling sessions. Measurements were made in 39 sessions performed by 300 experienced subjects. Sweat rate was categorized as SR1 ≥ 750, SR2 = 400-749 and SR3 < 400 ml; temperature increase as T1 ≤ 0.2, T2 = 0.2°C-1.5 and T3 > 1.5°C; and humidity as H1 ≤ 2, H2 = 2-15 and H3 > 15 percentage points. Mean HR was determined for the sessions and RPE recorded at the start, middle and end of each session. Significant differences in HR were observed between SR1 and SR3 (148.22 ± 12.17 vs 141.73 ± 17.39 bpm; p<0.05) and between T1 and T2 (141.01 ± 16.38 vs 146.95 ± 15.29 bpm; p<0.05). The RPE was lower (p<0.05) for T1 than T2 or T3 in all recordings and for H1 than H2 or H3 at the session start and middle. Our results indicate that real (%HRmax) and perceived (RPE) intensity of exercise in an indoor cycling session are influenced by factors such as the estimated sweat rate, or the increase in temperature or relative humidity produced in the cycling room.

  11. Corrections to the Shapiro Equation used to Predict Sweating and Water Requirements

    DTIC Science & Technology

    2008-01-01

    Nishi, Y., and A. P. Gagge. Effective temperature scale useful for hypobaric and hyperbaric environments. Aviat. Space Environ. Med. 48: 97-107, 1977...time series predictions of specific variables (35). Comparison of the original Shapiro equation predicting sweat loss and water requirements was...40 60 80 100 % O ff (+ ,m od el u nd er pr ed ic ts ;-, ov er pr ed ic ts ) It is clear from Figure 2’s plot of the residual values ( comparison

  12. Physiologic Systems and Their Responses to Conditions of Heat and Cold

    DTIC Science & Technology

    2012-01-01

    serial measures are made. Hypohydration increases heat storage by reducing sweating rate and skin blood-flow responses for a given core temperature. In...Capi’llary (3.5 L) E_xc_h~ (B%TBW) - - t Lymph Fluid Output I ) Urine Sweat ,JSF (1 1.5 L) (25% TBW) Osmotic Exchange ..._ _ ICF (30 L) (67%TBW...diuretics increase urine formation and generally result in the loss of boch solures and warer. Diuretic-induced hypohydrarion generally results in an

  13. Thermoregulatory responses and hydration practices in heat-acclimatized adolescents during preseason high school football.

    PubMed

    Yeargin, Susan Walker; Casa, Douglas J; Judelson, Daniel A; McDermott, Brendon P; Ganio, Matthew S; Lee, Elaine C; Lopez, Rebecca M; Stearns, Rebecca L; Anderson, Jeffrey M; Armstrong, Lawrence E; Kraemer, William J; Maresh, Carl M

    2010-01-01

    Previous researchers have not investigated the thermoregulatory responses to multiple consecutive days of American football in adolescents. To examine the thermoregulatory and hydration responses of high school players during formal preseason football practices. Observational study. Players practiced outdoors in late August once per day on days 1 through 5, twice per day on days 6 and 7, and once per day on days 8 through 10. Maximum wet bulb globe temperature averaged 23 +/- 4 degrees C. Twenty-five heat-acclimatized adolescent boys (age = 15 +/- 1 years, height = 180 +/- 8 cm, mass = 81.4 +/- 15.8 kg, body fat = 12 +/- 5%, Tanner stage = 4 +/- 1). We observed participants within and across preseason practices of football. Measures included gastrointestinal temperature (T(GI)), urine osmolality, sweat rate, forearm sweat composition, fluid consumption, testosterone to cortisol ratio, perceptual measures of thirst, perceptual measures of thermal sensation, a modified Environmental Symptoms Questionnaire, and knowledge questionnaires assessing the participants' understanding of heat illnesses and hydration. Results were analyzed for differences across time and were compared between younger (14-15 years, n = 13) and older (16-17 years, n = 12) participants. Maximum daily T(GI) values remained less than 40 degrees C and were correlated with maximum wet bulb globe temperature (r = 0.59, P = .009). Average urine osmolality indicated that participants generally experienced minimal to moderate hypohydration before (881 +/- 285 mOsmol/kg) and after (856 +/- 259 mOsmol/kg) each practice as a result of replacing approximately two-thirds of their sweat losses during exercise but inadequately rehydrating between practices. Age did not affect most variables; however, sweat rate was lower in younger participants (0.6 +/- 0.2 L/h) than in older participants (0.8 +/- 0.1 L/h) (F(1,18) = 8.774, P = .008). Previously heat-acclimatized adolescent boys (T(GI) < 40 degrees C) can safely complete the initial days of preseason football practice in moderate environmental conditions using well-designed practice guidelines. Adolescent boys replaced most sweat lost during practice but remained mildly hypohydrated throughout data collection, indicating inadequate hydration habits when they were not at practice.

  14. Multi-sector thermo-physiological head simulator for headgear research

    NASA Astrophysics Data System (ADS)

    Martinez, Natividad; Psikuta, Agnes; Corberán, José Miguel; Rossi, René M.; Annaheim, Simon

    2017-02-01

    A novel thermo-physiological human head simulator for headgear testing was developed by coupling a thermal head manikin with a thermo-physiological model. As the heat flux at head-site is directly measured by the head manikin, this method provides a realistic quantification of the heat transfer phenomena occurring in the headgear, such as moisture absorption-desorption cycles, condensation, or moisture migration across clothing layers. Before coupling, the opportunities of the head manikin for representing the human physiology were evaluated separately. The evaluation revealed reduced precision in forehead and face temperature predictions under extreme heterogeneous temperature distributions and no initial limitation for simulating temperature changes observed in the human physiology. The thermo-physiological model predicted higher sweat rates when applied for coupled than for pure virtual simulations. After coupling, the thermo-physiological human head simulator was validated using eight human experiments. It precisely predicted core, mean skin, and forehead temperatures with average rmsd values within the average experimental standard deviation (rmsd of 0.20 ± 0.15, 0.83 ± 0.34, and 1.04 ± 0.54 °C, respectively). However, in case of forehead, precision was lower for the exposures including activity than for the sedentary exposures. The representation of the human sweat evaporation could be affected by a reduced evaporation efficiency and the manikin sweat dynamics. The industry will benefit from this thermo-physiological human head simulator leading to the development of helmet designs with enhanced thermal comfort and, therefore, with higher acceptance by users.

  15. Exercise thermoregulation in men after 6 hours of immersion

    NASA Technical Reports Server (NTRS)

    Greenleaf, J. E.; Spaul, W. A.; Kravik, S. E.; Wong, N.; Elder, C. A.

    1985-01-01

    The present investigation is concerned with thermoregulation at rest and during exercise after water-immersion deconditioning, giving particular attention to the effects of fluid shifts and negative water balance on sweat rate and rectal temperature. Six healthy males 20-35 years old were used in the experiments. Rectal and mean skin temperature, skin heat conductance, heart rate, and total body sweat rate were measured during 70 min of supine leg exercise at 50 percent of peak O2 uptake. The data were taken after a 6-h control period in air and after immersion to the neck in water (34.5 C) for 6 h after overnight food and fluid restriction. Attention is given to end exercise heart rates and data during exercise. The obtained results suggest that, compared with control responses, the equilibrium level of core temperature during submaximal exercise is regulated at a higher level after immersion.

  16. Liquid-circulating garment controls thermal balance

    NASA Technical Reports Server (NTRS)

    Kuznetz, L. H.

    1977-01-01

    Experimental data and mathematical model of human thermoregulatory system have been used to investigate use of liquid-circulatory garment (LCG) to control thermal balance. Model proved useful as accurate simulator of such variables as sweat rate, skin temperature, core temperature, and radiative, evaporative, and LCG heat loss.

  17. Fluid-electrolyte shifts and thermoregulation: Rest and work in heat with head cooling.

    PubMed

    Greenleaf, J E; Van Beaumont, W; Brock, P J; Montgomery, L D; Morse, J T; Shvartz, E; Kravik, S

    1980-08-01

    Plasma volume and thermoregulatory responses were measured, during head and neck cooling with a liquid-cooled neoprene headgear, in four men (21-43 years old) during 60 min of rest, 60 min of ergometer exercise (45% VO2 max), and 30 min of recovery in the supine position at 40.1 degrees C DBT and 40% rh. Compared with control (noncooling) responses, cooling decreased thigh sweating and increased mean skin temperature (Tsk) at rest, and attenuated the increases in thigh sweating by 0.26 mg/min x cm2 (-22.4%, p < 0.05), heart rate by 10 b/min (-8.5%, N.S.), rectal temperature (Tre) by 0.3 degrees C (N.S.), and ventilation by 12.5% (N.S.) during exercise. In recovery, cooling facilitated the decreases in thigh sweat rate, heart rate, Tre, and forearm blood flow, and enhanced the increase in Tsk toward control levels. Cooling had no effect upon plasma protein, osmotic, or electrolyte shifts during rest, exercise, or recovery. Plasma volume (PV) loss during exercise was 11.2% without cooling and 10.9% with cooling. Cooling increased PV by 3% (p < 0.05) during rest, and this differential was maintained throughout the exercise and recovery periods.

  18. Cooling System to Treat Exercise-Induced Hyperthermia

    DTIC Science & Technology

    2016-06-01

    temperatures . Additionally, individual variations in sweat rates, ventilation rates, fitness levels, and oxygen consumption were not...gastrointestinal MHR maximum heart rate NASA National Aeronautics and Space Administration Tc core temperature UCHS uncompensated heat stress VO2peak peak oxygen consumption ...the effectiveness of a cooling pump based patient thermal management system supplied by Aspen Systems on lowering core body temperature

  19. Effects of duration of stay in temperate area on thermoregulatory responses to passive heat exposure in tropical south-east Asian males residing in Japan

    PubMed Central

    2012-01-01

    Background In this study, we investigated the effects of duration of stay in a temperate area on the thermoregulatory responses to passive heat exposure of residents from tropical areas, particularly to clarify whether they would lose their heat tolerance during passive heat exposure through residence in a temperate country, Japan. Methods We enrolled 12 males (mean ± SE age 25.7 ± 1.3 years) from south-east Asian countries who had resided in Japan for a mean of 24.5 ± 5.04 months, and 12 Japanese males (age 24.1 ± 0.9 years). Passive heat exposure was induced through leg immersion in hot water (42°C) for 60 minutes under conditions of 28°C air temperature and 50% relative humidity. Results Compared with the Japanese group, the tropical group displayed a higher pre-exposure rectal temperature (P < 0.01) and a smaller increase in rectal temperature during 60 minutes of leg immersion (P = 0.03). Additionally, the tropical group showed a tendency towards a lower total sweat rate (P = 0.06) and lower local sweat rate on the forehead (P = 0.07). The tropical group also had a significantly longer sweating onset time on the upper back (P = 0.04) compared with the Japanese groups. The tropical group who stayed in Japan for > 23 months sweated earlier on the forehead and upper back than those who stayed in Japan < 11 months (P < 0.01 and P = 0.03 for the forehead and upper back, respectively). There was a positive correlation between duration of stay in Japan and total sweat rate (r = 0.58, P <0.05), and negative correlations between duration of stay and sweating onset time on the forehead (r = −0.73, P = 0.01) and on the upper back (r = −0.66, P = 0.02). Other physiological indices measured in this study did not show any difference between the subjects in the tropical group who had lived in Japan for a shorter time and those who had lived there for a longer time. Conclusions We conclude that the nature of heat acclimatization of the sweating responses to passive heat exposure that are acquired from long-term heat acclimatization is decayed by a stay in a temperate area, as shown by the subjects in our tropical group. We did not find any evidence of a decay in the other physiological indices, indicating that heat tolerance acquired from long-term heat acclimatization is not completely diminished through residence in a temperate area for less than 4 years, although some aspects of this heat tolerance may be decayed. PMID:22974339

  20. Individual variability in the core interthreshold zone as related to body physique, somatotype, and physical constitution.

    PubMed

    Kakitsuba, Naoshi; Mekjavic, Igor B; Katsuura, Tetsuo

    2009-11-01

    For evaluating the effect of body physique, somatotype, and physical constitution on individual variability in the core interthreshold zone (CIZ), data from 22 healthy young Japanese male subjects were examined. The experiment was carried out in a climatic chamber in which air temperature was maintained at 20-24 degrees C. The subjects' body physique and the maximum work load were measured. Somatotype was predicted from the Heath-Carter Somatotype method. In addition, factors reflecting physical constitution, for example, susceptibility to heat and cold, and quality of sleep were obtained by questionnaire. The subjects wore a water-perfused suit which was perfused with water at a temperature of 25 degrees C and at a rate of 600 cc/min, and exercised on an ergometer at 50% of their maximum work rate for 10-15 min until their sweating rate increased. They then remained continuously seated without exercise until shivering increased. Rectal temperature (T(re)) and skin temperatures at four sites were monitored by thermistors, and sweating rate was measured at the forehead with a sweat rate monitor. Oxygen uptake was monitored with a gas analyzer. The results showed individual variability in the CIZ. According to the reciprocal cross-inhibition (RCI) theory, thermoafferent information from peripheral and core sensors is activated by T(re), mean skin temperature (T(sk)), and their changes. Since T(sk) was relatively unchanged, the data were selected to eliminate the influence of the core cooling rate on the sensor-to-effector pathway before RCI, and the relationship between the CIZ and the various factors was then analyzed. The results revealed that susceptibility to heat showed a good correlation with the CIZ, indicating that individual awareness of heat may change the CIZ due to thermoregulatory behavior.

  1. Thermal stress in seven types of chemical defense ensembles during moderate exercise in hot environments. Final report, May 1991-July 1992

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bomalaski, S.H.; Hengst, R.; Constable, S.H.

    United States Air Force -(USAF) personnel must perform their duties in many operational environments, including those with the potential for contamination with toxic chemical warfare (CW) agents. This study evaluated the physiological response to thermal stress in subjects performing moderate work in current and prototype chemical protective garments including the Battle Dress Overgarment (BDO)+BDU, BDO without BDU, United Kingdom (UK) undercoverall+BDU, Gore-Tex rainsuit+PJ-7 undercoverall, Marine Light Fighter Suit (MLFS), CWU77P, PJ-7 alone, and the BDU alone. Experimental conditions were dry bulb temperature of 40 deg C (104 deg F), a wet bulb temperature of 270C (80.6 deg F), and amore » black globe temperature of 450C (113 deg F). Eleven subjects walked on a treadmill at 3 mph with a 5% grade incline until rectal temperature (Tre) rose 1.5 deg C (2.7 deg F) above the starting value. Heart rate, rectal and mean skin temperature, and body heat storage were monitored continuously. Sweat evaporation and production were determined from the differences between pre- and postexperiment clothed and nude weights. Significantly longer work times, lower heart rates, lower Tmsk, and lower heat storage, were seen in the group comprised of the BDU, MLFS, CWU-77P, and PJ-7 compared to the Gore-Tex with PJ-7, UK plus BD BDO+BDU, and BDO no BDU ensembles. Suits which resulted in shorter tolerance times also caused rates of sweat production and lower % sweat evaporation than the less physiologically burdensome suits. Chemical protective ensembles, Thermal stress, Clothing, Exercise.« less

  2. A Wearable Microfluidic Sensing Patch for Dynamic Sweat Secretion Analysis.

    PubMed

    Nyein, Hnin Yin Yin; Tai, Li-Chia; Ngo, Quynh Phuong; Chao, Minghan; Zhang, George B; Gao, Wei; Bariya, Mallika; Bullock, James; Kim, Hyungjin; Fahad, Hossain M; Javey, Ali

    2018-05-25

    Wearable sweat sensing is a rapidly rising research area driven by its promising potential in health, fitness, and diagnostic applications. Despite the growth in the field, major challenges in relation to sweat metrics remain to be addressed. These challenges include sweat rate monitoring for its complex relation with sweat compositions and sweat sampling for sweat dynamics studies. In this work, we present a flexible microfluidic sweat sensing patch that enhances real-time electrochemical sensing and sweat rate analysis via sweat sampling. The device contains a spiral-patterned microfluidic component that is embedded with ion-selective sensors and an electrical impedance-based sweat rate sensor on a flexible plastic substrate. The patch is enabled to autonomously perform sweat analysis by interfacing the sensing component with a printed circuit board that is capable of on-site signal conditioning, analysis, and transmission. Progressive sweat flow in the microfluidic device, governed by the pressure induced by the secreted sweat, enhances sweat sampling and electrochemical detection via a defined sweat collection chamber and a directed sweat route. The characteristic of the sweat rate sensor is validated through a theoretical simulation, and the precision and accuracy of the flow rate is verified with a commercial syringe pump and a Macroduct sweat collector. On-body simultaneous monitoring of ion (H + , Na + , K + , Cl - ) concentration and sweat rate is also demonstrated for sensor functionality. This sweat sensing patch provides an integrated platform for a comprehensive sweat secretion analysis and facilitates physiological and clinical investigations by closely monitoring interrelated sweat parameters.

  3. Propranolol (Infantile Hemangioma)

    MedlinePlus

    ... or has had asthma or other breathing problems, pheochromocytoma (a tumor on a small gland near the ... color sweating irritability decreased appetite low body temperature unusual sleepiness breathing stops for short periods of time ...

  4. Responses to hyperthermia. Optimizing heat dissipation by convection and evaporation: Neural control of skin blood flow and sweating in humans.

    PubMed

    Smith, Caroline J; Johnson, John M

    2016-04-01

    Under normothermic, resting conditions, humans dissipate heat from the body at a rate approximately equal to heat production. Small discrepancies between heat production and heat elimination would, over time, lead to significant changes in heat storage and body temperature. When heat production or environmental temperature is high the challenge of maintaining heat balance is much greater. This matching of heat elimination with heat production is a function of the skin circulation facilitating heat transport to the body surface and sweating, enabling evaporative heat loss. These processes are manifestations of the autonomic control of cutaneous vasomotor and sudomotor functions and form the basis of this review. We focus on these systems in the responses to hyperthermia. In particular, the cutaneous vascular responses to heat stress and the current understanding of the neurovascular mechanisms involved. The available research regarding cutaneous active vasodilation and vasoconstriction is highlighted, with emphasis on active vasodilation as a major responder to heat stress. Involvement of the vasoconstrictor and active vasodilator controls of the skin circulation in the context of heat stress and nonthermoregulatory reflexes (blood pressure, exercise) are also considered. Autonomic involvement in the cutaneous vascular responses to direct heating and cooling of the skin are also discussed. We examine the autonomic control of sweating, including cholinergic and noncholinergic mechanisms, the local control of sweating, thermoregulatory and nonthermoregulatory reflex control and the possible relationship between sudomotor and cutaneous vasodilator function. Finally, we comment on the clinical relevance of these control schemes in conditions of autonomic dysfunction. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. Spatiotemporal antagonism in mesenchymal-epithelial signaling in sweat versus hair fate decision.

    PubMed

    Lu, Catherine P; Polak, Lisa; Keyes, Brice E; Fuchs, Elaine

    2016-12-23

    The gain of eccrine sweat glands in hairy body skin has empowered humans to run marathons and tolerate temperature extremes. Epithelial-mesenchymal cross-talk is integral to the diverse patterning of skin appendages, but the molecular events underlying their specification remain largely unknown. Using genome-wide analyses and functional studies, we show that sweat glands are specified by mesenchymal-derived bone morphogenetic proteins (BMPs) and fibroblast growth factors that signal to epithelial buds and suppress epithelial-derived sonic hedgehog (SHH) production. Conversely, hair follicles are specified when mesenchymal BMP signaling is blocked, permitting SHH production. Fate determination is confined to a critical developmental window and is regionally specified in mice. In contrast, a shift from hair to gland fates is achieved in humans when a spike in BMP silences SHH during the final embryonic wave(s) of bud morphogenesis. Copyright © 2016, American Association for the Advancement of Science.

  6. Does type 1 diabetes alter post-exercise thermoregulatory and cardiovascular function in young adults?

    PubMed

    McGinn, R; Carter, M R; Barrera-Ramirez, J; Sigal, R J; Flouris, A D; Kenny, G P

    2015-10-01

    Recent data demonstrated that individuals with type 1 diabetes mellitus (T1DM) exhibit impaired sweating and increased rectal temperature (i.e., heat storage) during exercise compared with healthy controls. Our purpose in this study was to investigate the consequences of T1DM on post-exercise thermal homeostasis. Sixteen participants (eight controls matched with eight T1DM) performed 90 min of cycling followed by 60 min of seated recovery. Esophageal and rectal temperatures, sweating (forearm, chest, and upper back), skin blood flow [forearm and upper back, presented as cutaneous vascular conductance (CVC)], and blood pressure [mean arterial pressure (MAP)] were measured at baseline and throughout recovery. Esophageal temperature was similar during baseline and recovery between groups (P = 0.88). However, rectal temperature was elevated in our T1DM group throughout recovery (P = 0.05). Sweating and CVC were similar between groups at all sites from 10-min post-exercise until the end of recovery (P ≥ 0.16). While absolute MAP was similar between groups (P = 0.43), the overall decrease in MAP post-exercise was greater in controls from 20 min (T1DM: - 8 ± 5 vs control: - 13 ± 6 mmHg, P = 0.03) until the end of recovery. We conclude that despite increased heat storage during exercise, individuals with T1DM exhibit a suppression in heat loss similar to their healthy counterparts during recovery. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  7. Multi-sector thermo-physiological head simulator for headgear research.

    PubMed

    Martinez, Natividad; Psikuta, Agnes; Corberán, José Miguel; Rossi, René M; Annaheim, Simon

    2017-02-01

    A novel thermo-physiological human head simulator for headgear testing was developed by coupling a thermal head manikin with a thermo-physiological model. As the heat flux at head-site is directly measured by the head manikin, this method provides a realistic quantification of the heat transfer phenomena occurring in the headgear, such as moisture absorption-desorption cycles, condensation, or moisture migration across clothing layers. Before coupling, the opportunities of the head manikin for representing the human physiology were evaluated separately. The evaluation revealed reduced precision in forehead and face temperature predictions under extreme heterogeneous temperature distributions and no initial limitation for simulating temperature changes observed in the human physiology. The thermo-physiological model predicted higher sweat rates when applied for coupled than for pure virtual simulations. After coupling, the thermo-physiological human head simulator was validated using eight human experiments. It precisely predicted core, mean skin, and forehead temperatures with average rmsd values within the average experimental standard deviation (rmsd of 0.20 ± 0.15, 0.83 ± 0.34, and 1.04 ± 0.54 °C, respectively). However, in case of forehead, precision was lower for the exposures including activity than for the sedentary exposures. The representation of the human sweat evaporation could be affected by a reduced evaporation efficiency and the manikin sweat dynamics. The industry will benefit from this thermo-physiological human head simulator leading to the development of helmet designs with enhanced thermal comfort and, therefore, with higher acceptance by users.

  8. 7 CFR 29.2544 - Resweated.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... which has passed through a second fermentation under abnormally high temperatures or refermented with a... after its first fermentation and put through a forced or artificial sweat. [37 FR 13626, July 12, 1972...

  9. A novel washing algorithm for underarm stain removal

    NASA Astrophysics Data System (ADS)

    Acikgoz Tufan, H.; Gocek, I.; Sahin, U. K.; Erdem, I.

    2017-10-01

    After contacting with human sweat which comprise around 27% sebum, anti-perspirants comprising aluminium chloride or its compounds form a jel-like structure whose solubility in water is very poor. In daily use, this jel-like structure closes sweat pores and hinders wetting of skin by sweat. However, when in contact with garments, they form yellowish stains at the underarm of the garments. These stains are very hard to remove with regular machine washing. In this study, first of all, we focused on understanding and simulating such stain formation on the garments. Two alternative procedures are offered to form jel-like structures. On both procedures, commercially available spray or deo-stick type anti-perspirants, standard acidic and basic sweat solutions and artificial sebum are used to form jel-like structures, and they are applied on fabric in order to get hard stains. Secondly, after simulation of the stain on the fabric, we put our efforts on developing a washing algorithm specifically designed for removal of underarm stains. Eight alternative washing algorithms are offered with varying washing temperature, amounts of detergent, and pre-stain removal procedures. Better algorithm is selected by comparison of Tristimulus Y values after washing.

  10. Sweating response to passive stretch of the calf muscle during activation of forearm muscle metaboreceptors in heated humans.

    PubMed

    Amano, Tatsuro; Ichinose, Masashi; Nishiyasu, Takeshi; Inoue, Yoshimitsu; Koga, Shunsaku; Miwa, Mikio; Kondo, Narihiko

    2014-05-15

    Activation of muscle metaboreceptors and mechanoreceptors has been shown to independently influence the sweating response, while their integrative control effects remain unclear. We examined the sweating response when the two muscle receptors are concurrently activated in different limbs, as well as the blood pressure response. In total, 27 young males performed passive calf muscle stretches (muscle mechanoreceptor activation) for 30 s in a semisupine position with and without postisometric handgrip exercise muscle ischemia (PEMI, muscle metaboreceptor activation) at exercise intensities of 35 and 50% of maximum voluntary contraction (MVC) under hot conditions (ambient temperature, 35°C, relative humidity, 50%). Passive calf muscle stretching alone increased the mean sweating rate significantly on the forehead, chest, and thigh (SRmean) and mean arterial blood pressure (MAP), but not the heart rate (HR), from prestretching levels by 0.04 ± 0.01 mg·cm(2)·min(-1), 4.0 ± 1.3 mmHg (P < 0.05), and -1.0 ± 0.5 beats/min (P > 0.05), respectively. The SRmean and MAP during PEMI were significantly higher than those at rest. The passive calf muscle stretch during PEMI increased MAP significantly by 3.4 ± 1.0 and 2.0 ± 0.7 mmHg for 35 and 50% of MVC, respectively (P < 0.05), but not that of SRmean or HR at either exercise intensity. These results suggest that sweating and blood pressure responses to concurrent activation of the two muscle receptors in different limbs differ and that the influence of calf muscle mechanoreceptor activation alone on the sweating response disappears during forearm muscle metaboreceptor activation. Copyright © 2014 the American Physiological Society.

  11. Tolerance of Very Hot Humid Environments by Highly Acclimatized Bantu at Rest

    PubMed Central

    Wyndham, C. H.; Williams, C. G.; Morrison, J. F.; Heyns, A. J. A.; Siebert, J.

    1968-01-01

    In order to know as much as possible about human reactions under conditions of extreme ambient air temperatures, and about the ability of men to survive under these conditions and to assist in their own survival, a series of studies was made in which groups of 10 men were exposed to temperature conditions ranging from 96°F. to 104°F. wet bulb (W.B.). Rigid criteria were employed to decide when men should be withdrawn from the test conditions. These were: (a) reaching a rectal temperature of 104°F., (b) suffering from repeated attacks of heat collapse which prevented the subject from standing erect, and (c) suffering a change in temperament and being no longer susceptible to instructions. At W.B. temperatures of 104°F. and 102°F. the rectal temperatures of the men continued to rise in a straight line until they reached 104°F. There was no tendency for the rectal temperatures to reach a steady state. At 100°F. W.B. there was a definite tendency in the rectal temperatures towards a steady level, but a steady state was not reached until the rectal temperatures had reached 104°F. The same general trend was seen at 98°F., but the time taken to reach a steady state was increased considerably. At 96°F. the rectal temperatures reached a steady level of between 102°F. and 103°F. after about 12 hours of exposure. Superimposed on this steady level was a clearcut circadian rhythm in rectal temperature. At 104°F. the mean heart rate continued to rise until the men were withdrawn when it had reached 148 beats per minute. In all the other air conditions, the heart rates reached a relatively steady level and the maximum level attained was proportionate to the severity of the air conditions. The sweat rate increased steadily between 96°F. and 100°F. W.B. from 130 ml./hour to 300 ml./hour. Above 100°F. it increased sharply to reach 800 ml./hour at 102°F. and 875 ml./hour at 104°F. W.B. In contrast to the sweat rate, the hourly rate of water intake did not alter between 96°F. and 100°F. W.B., being approximately constant at 150 ml./hour, but at 102°F. and 104°F. W.B. it rose sharply to 310 ml./hour and 330 ml./hour respectively. The hourly urine output was 95 ml./hour at 96°F. W.B. but fell to 50 ml./hour at 98°F. W.B. and declined further to 35 ml./hour at 104°F. W.B. At 96°F. and 98°F. W.B. the water intake was approximately equal to the rate of sweat loss, but at 100°F. the sweat rate increased without any rise in water intake, so that the difference was about 150 ml./hour. At 102°F. and 104°F. W.B. the rate of sweating increased sharply. Although the rate of drinking also rose, the difference between intake and output had also increased to about 550 ml./hour at 104°F. W.B. The curve of the average rate of dehydration is very similar to that representing the rate of sweating. There was little difference in the rate of dehydration between 96°F. and 98°F. W.B., the rate being 80 ml./hour, but at 100°F. it rose to 210 ml./hour. Above 100°F. W.B. the rate of dehydration rose sharply as the rate of water intake lagged further behind the rate of sweating; it was 510 ml./hour at 104°F. W.B. The main psychological effects were on the men's temperaments. A number of men became aggressive, a few became hysterical, and a few maintained a stoical silence. At 96°F. W.B., when the men remained in the climatic rooms for 48 hours, there were periods of aggressive behaviour which alternated with apathy. Electroencephalograms were done on some subjects. No abnormalities of any kind were evoked or caused by exposure to heat. The tolerance times before which men, who were initially cool, would not have reached their limit of tolerance to heat were estimated. PMID:5642646

  12. Evaluation of protective ensemble thermal characteristics through sweating hot plate, sweating thermal manikin, and human tests.

    PubMed

    Kim, Jung-Hyun; Powell, Jeffery B; Roberge, Raymond J; Shepherd, Angie; Coca, Aitor

    2014-01-01

    The purpose of this study was to evaluate the predictive capability of fabric Total Heat Loss (THL) values on thermal stress that Personal Protective Equipment (PPE) ensemble wearers may encounter while performing work. A series of three tests, consisting of the Sweating Hot Plate (SHP) test on two sample fabrics and the Sweating Thermal Manikin (STM) and human performance tests on two single-layer encapsulating ensembles (fabric/ensemble A = low THL and B = high THL), was conducted to compare THL values between SHP and STM methods along with human thermophysiological responses to wearing the ensembles. In human testing, ten male subjects performed a treadmill exercise at 4.8 km and 3% incline for 60 min in two environmental conditions (mild = 22°C, 50% relative humidity (RH) and hot/humid = 35°C, 65% RH). The thermal and evaporative resistances were significantly higher on a fabric level as measured in the SHP test than on the ensemble level as measured in the STM test. Consequently the THL values were also significantly different for both fabric types (SHP vs. STM: 191.3 vs. 81.5 W/m(2) in fabric/ensemble A, and 909.3 vs. 149.9 W/m(2) in fabric/ensemble B (p < 0.001). Body temperature and heart rate response between ensembles A and B were consistently different in both environmental conditions (p < 0.001), which is attributed to significantly higher sweat evaporation in ensemble B than in A (p < 0.05), despite a greater sweat production in ensemble A (p < 0.001) in both environmental conditions. Further, elevation of microclimate temperature (p < 0.001) and humidity (p < 0.01) was significantly greater in ensemble A than in B. It was concluded that: (1) SHP test determined THL values are significantly different from the actual THL potential of the PPE ensemble tested on STM, (2) physiological benefits from wearing a more breathable PPE ensemble may not be feasible with incremental THL values (SHP test) less than approximately 150-200 W·m(2), and (3) the effects of thermal environments on a level of heat stress in PPE ensemble wearers are greater than ensemble thermal characteristics.

  13. Usefulness of Sweat Management for Patients with Adult Atopic Dermatitis, regardless of Sweat Allergy: A Pilot Study.

    PubMed

    Kaneko, Sakae; Murota, Hiroyuki; Murata, Susumu; Katayama, Ichiro; Morita, Eishin

    2017-01-01

    Background . Sweat is an aggravating factor in atopic dermatitis (AD), regardless of age. Sweat allergy may be involved in AD aggravated by sweating. Objective. We investigated whether sweat exacerbates adult AD symptoms and examined the extent of sweat allergy's involvement. Method. We asked 34 AD patients (17 men, 17 women; mean age: 27.8 years) to record the extent to which sweat aggravated their symptoms on a 10-point numerical scale. Participant responses were compared with histamine release tests (HRT). Furthermore, 24 of the patients received instructions on methods of sweat management, and their outcomes were evaluated on a 10-point scale. Results. Sweat HRT results were class ≥ 2 in 13 patients, but HRT results were not correlated with the patients' self-assessments of symptom aggravation by sweat. One month after receiving sweat management instructions, a low mean score of 4.6 was obtained regarding whether active sweating was good, but a high mean score of 7.0 was obtained in response to whether the sweat management instructions had been helpful. Conclusion . Our investigation showed that patients' negative impressions of sweat might derive from crude personal experiences that are typically linked to sweating. Sweat management for patients with adult atopic dermatitis was extremely useful regardless of sweat allergy.

  14. Personalized Hydration Strategy Attenuates the Rise in Heart Rate and in Skin Temperature Without Altering Cycling Capacity in the Heat.

    PubMed

    de Melo-Marins, Denise; Souza-Silva, Ana Angélica; da Silva-Santos, Gabriel Lucas Leite; Freire-Júnior, Francisco de Assis; Lee, Jason Kai Wei; Laitano, Orlando

    2018-01-01

    The optimal hydration plan [i.e., drink to thirst, ad libitum (ADL), or personalized plan] to be adopted during exercise in recreational athletes has recently been a matter of debate and, due to conflicting results, consensus does not exist. In the present investigation, we tested whether a personalized hydration strategy based on sweat rate would affect cardiovascular and thermoregulatory responses and exercise capacity in the heat. Eleven recreational male cyclists underwent two familiarization cycling sessions in the heat (34°C, 40% RH) where sweat rate was also determined. A fan was used to enhance sweat evaporation. Participants then performed three randomized time-to-exhaustion (TTE) trials in the heat with different hydration strategies: personalized volume (PVO), where water was consumed, based on individual sweat rate, every 10 min; ADL, where free access to water was allowed; and a control (CON) trial with no fluids. Blood osmolality and urine-specific gravity were measured before each trial. Heart rate (HR), rectal, and skin temperatures were monitored throughout trials. Time to exhaustion at 70% of maximal workload was used to define exercise capacity in the heat, which was similar in all trials ( p  = 0.801). Body mass decreased after ADL ( p  = 0.008) and CON ( p  < 0.001) and was maintained in PVO trials ( p  = 0.171). Participants consumed 0 ml in CON, 166 ± 167 ml in ADL, and 1,080 ± 166 ml in PVO trials. The increase in mean body temperature was similar among trials despite a lower increase in skin temperature during PVO trial in comparison with CON (2.1 ± 0.6 vs. 2.9 ± 0.5°C, p  = 0.0038). HR was lower toward the end of TTE in PVO (162 ± 8 bpm) in comparison with ADL (168 ± 12 bpm) and CON (167 ± 10 bpm), p  < 0.001. In conclusion, a personalized hydration strategy can reduce HR during a moderate to high intensity exercise session in the heat and halt the increase in skin temperature. Despite these advantages, cycling capacity in the heat remained unchanged.

  15. Personalized Hydration Strategy Attenuates the Rise in Heart Rate and in Skin Temperature Without Altering Cycling Capacity in the Heat

    PubMed Central

    de Melo-Marins, Denise; Souza-Silva, Ana Angélica; da Silva-Santos, Gabriel Lucas Leite; Freire-Júnior, Francisco de Assis; Lee, Jason Kai Wei; Laitano, Orlando

    2018-01-01

    The optimal hydration plan [i.e., drink to thirst, ad libitum (ADL), or personalized plan] to be adopted during exercise in recreational athletes has recently been a matter of debate and, due to conflicting results, consensus does not exist. In the present investigation, we tested whether a personalized hydration strategy based on sweat rate would affect cardiovascular and thermoregulatory responses and exercise capacity in the heat. Eleven recreational male cyclists underwent two familiarization cycling sessions in the heat (34°C, 40% RH) where sweat rate was also determined. A fan was used to enhance sweat evaporation. Participants then performed three randomized time-to-exhaustion (TTE) trials in the heat with different hydration strategies: personalized volume (PVO), where water was consumed, based on individual sweat rate, every 10 min; ADL, where free access to water was allowed; and a control (CON) trial with no fluids. Blood osmolality and urine-specific gravity were measured before each trial. Heart rate (HR), rectal, and skin temperatures were monitored throughout trials. Time to exhaustion at 70% of maximal workload was used to define exercise capacity in the heat, which was similar in all trials (p = 0.801). Body mass decreased after ADL (p = 0.008) and CON (p < 0.001) and was maintained in PVO trials (p = 0.171). Participants consumed 0 ml in CON, 166 ± 167 ml in ADL, and 1,080 ± 166 ml in PVO trials. The increase in mean body temperature was similar among trials despite a lower increase in skin temperature during PVO trial in comparison with CON (2.1 ± 0.6 vs. 2.9 ± 0.5°C, p = 0.0038). HR was lower toward the end of TTE in PVO (162 ± 8 bpm) in comparison with ADL (168 ± 12 bpm) and CON (167 ± 10 bpm), p < 0.001. In conclusion, a personalized hydration strategy can reduce HR during a moderate to high intensity exercise session in the heat and halt the increase in skin temperature. Despite these advantages, cycling capacity in the heat remained unchanged. PMID:29707541

  16. Speciation of mercury compounds by differential atomization - atomic absorption spectroscopy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Robinson, J.W.; Skelly, E.M.

    This paper describes the dual stage atomization technique which allows speciation of several mercury-containing compounds in aqueous solution and in biological fluids. The technique holds great promise for further speciation studies. Accurate temperature control, expecially at temperatures less than 200/sup 0/C, is needed to separate the extremely volatile mercury halides and simple organomercurials from each other. Studies with mercury salts and EDTA, L-cysteine and dithioxamide demonstrate that this technique may be used to study the extent of complex formation. Investigations of biological fluids indicate that there is a single predominant form of mercury in sweat and a single predominant formmore » of mercury in urine. The mercury compound in urine is more volatile than that in sweat. Both quantitative and qualitative analyses are possible with this technique.« less

  17. Latent heat loss and sweat gland histology of male goats in an equatorial semi-arid environment

    NASA Astrophysics Data System (ADS)

    de Melo Costa, Cíntia Carol; Maia, Alex Sandro Campos; Neto, José Domingues Fontenele; Oliveira, Steffan Edward Octávio; de Queiroz, João Paulo Araújo Fernandes

    2014-03-01

    The objective of this work was to quantify the heat loss by cutaneous evaporation of goats in an equatorial semi-arid environment. The latent heat loss from the body surfaces of these ten undefined breed goats was measured using a ventilated capsule in sun and shade and in the three body regions (neck, flank and hindquarters). Skin samples from these three regions were histologically analyzed to relate the quantity of sweat glands, the area of sweat glands and the epithelium thickness of each of these regions to the heat loss by cutaneous evaporation of the examined goats. The epithelium thickness that was measured varied significantly for body regions with different quantities and areas of sweat glands ( P < 0.01). Among the body regions that were examined, the samples from the neck demonstrated the highest epithelium thickness (16.23 ± 0.13 μm). However, the samples of sweat glands from the flank had the biggest area (43330.51 ± 778.71 μm2) and quantity per square centimeter (390 ± 9 cm-2). After the animals were exposed to sun, the flanks lost the greatest amount of heat by cutaneous evaporation (73.03 ± 1.75 W m-2) and possessed the highest surface temperatures (39.47 ± 0.18 °C). The histological characteristics may have influenced the heat loss by cutaneous evaporation that was observed in the flank region after the animals were exposed to sun.

  18. Assessment of body mapping sportswear using a manikin operated in constant temperature mode and thermoregulatory model control mode

    NASA Astrophysics Data System (ADS)

    Wang, Faming; Del Ferraro, Simona; Molinaro, Vincenzo; Morrissey, Matthew; Rossi, René

    2014-09-01

    Regional sweating patterns and body surface temperature differences exist between genders. Traditional sportswear made from one material and/or one fabric structure has a limited ability to provide athletes sufficient local wear comfort. Body mapping sportswear consists of one piece of multiple knit structure fabric or of different fabric pieces that may provide athletes better wear comfort. In this study, the `modular' body mapping sportswear was designed and subsequently assessed on a `Newton' type sweating manikin that operated in both constant temperature mode and thermophysiological model control mode. The performance of the modular body mapping sportswear kit and commercial products were also compared. The results demonstrated that such a modular body mapping sportswear kit can meet multiple wear/thermal comfort requirements in various environmental conditions. All body mapping clothing (BMC) presented limited global thermophysiological benefits for the wearers. Nevertheless, BMC showed evident improvements in adjusting local body heat exchanges and local thermal sensations.

  19. Assessment of body mapping sportswear using a manikin operated in constant temperature mode and thermoregulatory model control mode.

    PubMed

    Wang, Faming; Del Ferraro, Simona; Molinaro, Vincenzo; Morrissey, Matthew; Rossi, René

    2014-09-01

    Regional sweating patterns and body surface temperature differences exist between genders. Traditional sportswear made from one material and/or one fabric structure has a limited ability to provide athletes sufficient local wear comfort. Body mapping sportswear consists of one piece of multiple knit structure fabric or of different fabric pieces that may provide athletes better wear comfort. In this study, the 'modular' body mapping sportswear was designed and subsequently assessed on a 'Newton' type sweating manikin that operated in both constant temperature mode and thermophysiological model control mode. The performance of the modular body mapping sportswear kit and commercial products were also compared. The results demonstrated that such a modular body mapping sportswear kit can meet multiple wear/thermal comfort requirements in various environmental conditions. All body mapping clothing (BMC) presented limited global thermophysiological benefits for the wearers. Nevertheless, BMC showed evident improvements in adjusting local body heat exchanges and local thermal sensations.

  20. Dynamic analysis for mental sweating of a group of eccrin sweat glands on a human fingertip by optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Ohmi, Masato; Tanigawa, Motomu; Wada, Yuki; Haruna, Masamitsu

    2011-05-01

    OCT is highly potential for in vivo observation of human sweating dynamics which affects activity of the sympathetic nerve. In this paper, we demonstrate dynamic OCT analysis of mental sweating of a group of eccrin sweat glands. The sweating dynamics is tracked simultaneously for nineteen sweat glands by time-sequential piled-up en-face OCT images with the frame spacing of 3.3 sec. Strong non-uniformity is observed in mental sweating where the amount of excess sweat is different for each sweat gland although the sweat glands are adjacent to each other. The non-uniformity should be necessary to adjust as precisely the total amount of excess sweat as possible through the sympathetic nerve in response to strength of the stress.

  1. Large differences in peak oxygen uptake do not independently alter changes in core temperature and sweating during exercise.

    PubMed

    Jay, Ollie; Bain, Anthony R; Deren, Tomasz M; Sacheli, Matthew; Cramer, Matthew N

    2011-09-01

    The independent influence of peak oxygen uptake (Vo(₂ peak)) on changes in thermoregulatory responses during exercise in a neutral climate has not been previously isolated because of complex interactions between Vo(₂ peak), metabolic heat production (H(prod)), body mass, and body surface area (BSA). It was hypothesized that Vo(₂ peak) does not independently alter changes in core temperature and sweating during exercise. Fourteen males, 7 high (HI) Vo(₂ peak): 60.1 ± 4.5 ml·kg⁻¹·min⁻¹; 7 low (LO) Vo(₂ peak): 40.3 ± 2.9 ml·kg⁻¹·min⁻¹ matched for body mass (HI: 78.2 ± 6.1 kg; LO: 78.7 ± 7.1 kg) and BSA (HI: 1.97 ± 0.08 m²; LO: 1.94 ± 0.08 m²), cycled for 60-min at 1) a fixed heat production (FHP trial) and 2) a relative exercise intensity of 60% Vo(₂ peak) (REL trial) at 24.8 ± 0.6°C, 26 ± 10% RH. In the FHP trial, H(prod) was similar between the HI (542 ± 38 W, 7.0 ± 0.6 W/kg or 275 ± 25 W/m²) and LO (535 ± 39 W, 6.9 ± 0.9 W/kg or 277 ± 29 W/m²) groups, while changes in rectal (T(re): HI: 0.87 ± 0.15°C, LO: 0.87 ± 0.18°C, P = 1.00) and aural canal (T(au): HI: 0.70 ± 0.12°C, LO: 0.74 ± 0.21°C, P = 0.65) temperature, whole-body sweat loss (WBSL) (HI: 434 ± 80 ml, LO: 440 ± 41 ml; P = 0.86), and steady-state local sweating (LSR(back)) (P = 0.40) were all similar despite relative exercise intensity being different (HI: 39.7 ± 4.2%, LO: 57.6 ± 8.0% Vo(2 peak); P = 0.001). At 60% Vo(2 peak), H(prod) was greater in the HI (834 ± 77 W, 10.7 ± 1.3 W/kg or 423 ± 44 W/m²) compared with LO (600 ± 90 W, 7.7 ± 1.4 W/kg or 310 ± 50 W/m²) group (all P < 0.001), as were changes in T(re) (HI: 1.43 ± 0.28°C, LO: 0.89 ± 0.19°C; P = 0.001) and T(au) (HI: 1.11 ± 0.21°C, LO: 0.66 ± 0.14°C; P < 0.001), and WBSL between 0 and 15, 15 and 30, 30 and 45, and 45 and 60 min (all P < 0.01), and LSR(back) (P = 0.02). The absolute esophageal temperature (T(es)) onset for sudomotor activity was ∼0.3°C lower (P < 0.05) in the HI group, but the change in T(es) from preexercise values before sweating onset was similar between groups. Sudomotor thermosensitivity during exercise were similar in both FHP (P = 0.22) and REL (P = 0.77) trials. In conclusion, changes in core temperature and sweating during exercise in a neutral climate are determined by H(prod), mass, and BSA, not Vo(₂ peak).

  2. Exercise Thermoregulation Following 13 Days of Bed Rest

    NASA Technical Reports Server (NTRS)

    Lee, Stuart M. C.; Williams, W. Jon; Schneider, Suzanne M.

    2001-01-01

    This investigation examined two potential mechanisms, altered skin blood flow (SBF) and sweating rate (SR) responses, that may be responsible for an elevated core temperature during exercise after bed rest (BR) and space flight. Seven healthy men (29 +/- 5 yr, 179.6 +/- 7.1 cm, 77.2 +/- 17.0kg; mean +/- SD) underwent 13 days of 6 deg head-down BR. Pre- and post-BR, subjects completed supine submaximal cycle ergometry (20 min at 40% and 20 min at 65% of pre-BR supine VO2pk) in a thermoneutral room (23.4 +/- 0.5 C, 56 +/- 8 %RH) during, heat production (VO2 ; indirect calorimetry), intestinal temperature (T(sub in) ; ingestible pill), SBF (laser Doppler velocimetry), local SR (dew point hygrometry), and total sweat loss (TSL; Delta body weight) were measured. Pre- and post- BR plasma volume (PV) was measured using I-125 dilution. After BR, T(sub in) was elevated at rest (36.99 +/- 0.14 vs. 37.30 +/- 0.06 C; p<_0.05) and at the end of exercise (37.57 +/- 0.13 vs. 37.90 +/- 0.09 C; P less than or equal to 0.05). However, the increase in T(sub in) from rest to the end of exercise was not different after BR (0.59 +/- 0.07 vs. 0.60 +/- 0.07 C). There was no difference in VO2 pre- to post-BR during rest (0.28 +/- 0.04 vs. 0.24 +/- 0.03 1 multiplied by min(exp -1) ) or 40% VO2pk (0.95 +/- 0.08 vs. 0.96 +/- 0.05 1 multiplied by min(exp -1)), but VO2 was significantly less at the end of the 65% VO2pk stage (1.53 +/- 0.09 vs. 1.42 +/- 0.11 1 multiplies by min(exp - 1); p less than or equal to 0.05). The percent change in SBF from rest to end of exercise was less after BR (211 +/- 53 vs. 96 +/- 31%; p less than or equal to 0.05), the threshold for the onset of SBF was greater (37.17 +/- 0.18vs. 37.51 +/- 0.17 C; p less than or equal to 0.05), and the slope of the response tended to be reduced (536 +/- 184 vs. 201 +/- 46 %A PC; p=0.08). TSL was not different after BR (0.42+0.06 vs. 0.44 +/- 0.08 kg), but the T in threshold at the onset of sweating was delayed significantly (37.06 +/- 0.1 1 vs. 37.34 +/- 0.06 C; p less than or equal to 0.05). However, the slope of SR was not changed after BR (3.45 +/- 1.22 vs. 2.58 +/- 0.71 mg multiplied by min(exp -1) multiplied by cm sq). PV was decreased by 11% after BR (3,259 +/- 177 vs. 2,894 +/- 138 ml; p less than or equal to 0.05). These results suggest that exercise SBF and SR responses after BR are altered, and heat production is unchanged or reduced, consistent with observations following space flight. The higher resting T(sub in) with a proportional increase in T(sub in) during exercise and delayed onset of SBF and SR suggest a centrally-mediated elevation in the thermoregulatory set point during microgravity exposure.

  3. Morphological dependency of cutaneous blood flow and sweating during compensable heat stress when heat-loss requirements are matched across participants.

    PubMed

    Notley, Sean R; Park, Joonhee; Tagami, Kyoko; Ohnishi, Norikazu; Taylor, Nigel A S

    2016-07-01

    Human heat loss is thought, in part, to be morphologically related. It was therefore hypothesized that when heat-loss requirements and body temperatures were matched, that the mass-specific surface area alone could significantly explain both cutaneous vascular and sudomotor responses during compensable exercise. These thermoeffector responses were examined in 36 men with widely varying mass-specific surface areas (range, 232.3-292.7 cm(2)/kg), but of similar age, aerobic fitness, and adiposity. Subjects completed two trials under compensable conditions (28.1°C, 36.8% relative humidity), each involving rest (20 min) and steady-state cycling (45 min) at two matched metabolic heat-production rates (light, ∼135 W/m(2); moderate, ∼200 W/m(2)). Following equivalent mean body temperature changes, forearm blood flow and vascular conductance (r = 0.63 and r = 0.65) shared significant, positive associations with the mass-specific surface area during light work (P < 0.05), explaining ∼45% of the vasomotor variation. Conversely, during light and moderate work, whole body sweat rate, as well as local sweat rate and sudomotor sensitivity at three of four measured sites, revealed moderate, negative relationships with the mass-specific surface area (correlation coefficient range -0.37 to -0.73, P < 0.05). Moreover, those relationships could uniquely account for between 10 and 53% of those sweating responses (P < 0.05). Therefore, both thermoeffector responses displayed a significant morphological dependency in the presence of equivalent thermoafferent drive. Indeed, up to half of the interindividual variation in these effector responses could now be explained through morphological differences and the first principles governing heat transfer. Copyright © 2016 the American Physiological Society.

  4. Age Modulates Physiological Responses during Fan Use under Extreme Heat and Humidity.

    PubMed

    Gagnon, Daniel; Romero, Steven A; Cramer, Matthew N; Kouda, Ken; Poh, Paula Y S; Ngo, Hai; Jay, Ollie; Crandall, Craig G

    2017-11-01

    We examined the effect of electric fan use on cardiovascular and thermoregulatory responses of nine young (26 ± 3 yr) and nine aged (68 ± 4 yr) adults exposed to extreme heat and humidity. While resting at a temperature of 42°C, relative humidity increased from 30% to 70% in 2% increments every 5 min. On randomized days, the protocol was repeated without or with fan use. HR, core (Tcore) and mean skin (Tsk) temperatures were measured continuously. Whole-body sweat loss was measured from changes in nude body weight. Other measures of cardiovascular (cardiac output), thermoregulatory (local cutaneous and forearm vascular conductance, local sweat rate), and perceptual (thermal and thirst sensations) responses were also examined. When averaged over the entire protocol, fan use resulted in a small reduction of HR (-2 bpm, 95% confidence interval [CI], -8 to 3), and slightly greater Tcore (+0.05°C; 95% CI, -0.13 to 0.23) and Tsk (+0.03°C; 95% CI, -0.36 to 0.42) in young adults. In contrast, fan use resulted in greater HR (+5 bpm; 95% CI, 0-10), Tcore (+0.20°C; 95% CI, 0.00-0.41), and Tsk (+0.47°C; 95% CI, 0.18-0.76) in aged adults. A greater whole-body sweat loss during fan use was observed in young (+0.2 kg; 95% CI, -0.2 to 0.6) but not aged (0.0 kg; 95% CI, -0.2 to 0.2) adults. Greater local sweat rate and cutaneous vascular conductance were observed with fan use in aged adults. Other measures of cardiovascular, thermoregulatory, and perceptual responses were unaffected by fan use in both groups. During extreme heat and humidity, fan use elevates physiological strain in aged, but not young, adults.

  5. Morphological dependency of cutaneous blood flow and sweating during compensable heat stress when heat-loss requirements are matched across participants

    PubMed Central

    Notley, Sean R.; Park, Joonhee; Tagami, Kyoko; Ohnishi, Norikazu

    2016-01-01

    Human heat loss is thought, in part, to be morphologically related. It was therefore hypothesized that when heat-loss requirements and body temperatures were matched, that the mass-specific surface area alone could significantly explain both cutaneous vascular and sudomotor responses during compensable exercise. These thermoeffector responses were examined in 36 men with widely varying mass-specific surface areas (range, 232.3-292.7 cm2/kg), but of similar age, aerobic fitness, and adiposity. Subjects completed two trials under compensable conditions (28.1°C, 36.8% relative humidity), each involving rest (20 min) and steady-state cycling (45 min) at two matched metabolic heat-production rates (light, ∼135 W/m2; moderate, ∼200 W/m2). Following equivalent mean body temperature changes, forearm blood flow and vascular conductance (r = 0.63 and r = 0.65) shared significant, positive associations with the mass-specific surface area during light work (P < 0.05), explaining ∼45% of the vasomotor variation. Conversely, during light and moderate work, whole body sweat rate, as well as local sweat rate and sudomotor sensitivity at three of four measured sites, revealed moderate, negative relationships with the mass-specific surface area (correlation coefficient range −0.37 to −0.73, P < 0.05). Moreover, those relationships could uniquely account for between 10 and 53% of those sweating responses (P < 0.05). Therefore, both thermoeffector responses displayed a significant morphological dependency in the presence of equivalent thermoafferent drive. Indeed, up to half of the interindividual variation in these effector responses could now be explained through morphological differences and the first principles governing heat transfer. PMID:27125845

  6. Sweating

    MedlinePlus

    ... Home Body Looking and feeling your best Sweating Sweating You might think that you are only supposed to sweat when you are hot, but once you hit puberty, you will also sweat when you are nervous. Your sweat glands, which ...

  7. The interrelationship of research in the laboratory and the field to assess hydration status and determine mechanisms involved in water regulation during physical activity.

    PubMed

    Stachenfeld, Nina S

    2014-05-01

    Changes in skin blood and sweating are the primary mechanisms for heat loss in humans. A hot, humid environment concomitant with dehydration limits the ability to increase skin blood flow for the purpose of transferring heat from the body core to skin surface and evaporate sweat to maintain core temperature within safe limits during exercise. Adequate hydration improves thermoregulation by maintaining blood volume to support skin blood flow and sweating. Humans rely on fluid intake to maintain total body water and blood volume, and have developed complex mechanisms to sense changes in the amount and composition of fluid in the body. This paper addresses the interrelationship of research in the laboratory and the field to assess hydration status involved in body water and temperature regulation during exercise. In the controlled setting of a research laboratory, investigators are able to investigate the contributions of volume and tonicity of fluid in the plasma to body water and temperature regulation during exercise and recovery. For example, laboratory studies have shown that tonicity in a rehydration beverage maintains the thirst mechanism (and stimulates drinking), and contributes to the ongoing stimulation of renal fluid retention hormones, ultimately leading to a more complete rehydration. Research in the field cannot control the environment precisely, but these studies provide a natural, 'real-life' setting to study fluid and temperature regulation during exercise. The conditions encountered in the field are closest to the environment during competition, and data collected in the field can have an immediate impact on performance and safety during exercise. There is an important synergy between these two methods of collecting data that support performance and protect athletes from harm during training and improve performance during competition.

  8. Sweating the small stuff: adequacy and accuracy in sweat chloride determination.

    PubMed

    DeMarco, Mari L; Dietzen, Dennis J; Brown, Sarah M

    2015-04-01

    Sweat chloride testing is the gold standard for diagnosis of cystic fibrosis (CF). Our objectives were to: 1) describe variables that determine sweat rate; 2) determine the analytic and diagnostic capacity of sweat chloride analysis across the range of observed sweat rates; and 3) determine the biologic variability of sweat chloride concentration. A retrospective analysis was performed using data from all sweat chloride tests performed at St. Louis Children's Hospital over a 21-month period. A total of 1397 sweat chloride tests (1155 sufficient [≥75 mg], 242 insufficient [<75 mg]), were performed on 904 individuals. The sweat weight collected from forearms was statistically greater than that collected from legs. There was a negligible correlation between sweat weight and chloride concentration (r=-0.06). The mean individual biologic CV calculated from individuals with two or more sweat collections ≥75 mg was 13.1% (95% CI: 11.3-14.9%; range 0-88%) yielding a reference change value of 36%. Using 60 mmol/L as the diagnostic chloride cutoff, 100% of CF cases were detected whether a minimum sweat weight of 75, 40, or 20 mg was required. 1) Collection of sweat from forearms is preferable to upper legs, particularly in very young infants; 2) sweat chloride concentrations are not highly dependent upon sweat rate; 3) a change in sweat chloride concentration exceeding 36% may be considered a clinically significant response to cystic fibrosis transmembrane receptor targeted therapy, and 4) sweat collections of less than 75 mg provide clinically accurate information. Copyright © 2014 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  9. Sweating responses to isometric hand-grip exercise and forearm muscle metaboreflex in prepubertal children and elderly.

    PubMed

    Amano, Tatsuro; Kai, Seiko; Nakajima, Michi; Ichinose-Kuwahara, Tomoko; Gerrett, Nicola; Kondo, Narihiko; Inoue, Yoshimitsu

    2017-02-01

    What is the central question of this study? Non-thermal factors (e.g. muscle metaboreflex) contribute to the sweating response during exercise. Although it is well recognized that the sweating responses caused by core temperature elevation in prepubertal children and the elderly are attenuated compared with young adults, it is unknown whether non-thermal sweating is also attenuated in these populations. What is the main finding and its importance? The non-thermal sweating response during isometric hand-grip exercise and isolated muscle metaboreflex were attenuated in prepubertal children compared with young adults in a non-uniform manner over the body, but only during the muscle metaboreflex in the elderly. This may explain the maturation- and ageing-related decline of sweating during exercise. The purpose of the present study was to investigate sweating responses to isometric hand-grip (IH) exercise and muscle metaboreflex in prepubertal children and the elderly. In hot conditions (ambient temperature, 35°C; relative humidity, 45%), 13 healthy young adults, 10 prepubertal children and 10 elderly subjects (aged 20.4 ± 1.2, 11.4 ± 0.5 and 63.5 ± 3.1 years, respectively) repeated a three hand-grip exercise protocol that consisted of 1 min IH exercise at 15, 30 or 45% of maximal voluntary contraction (MVC) followed by 2 min postexercise forearm occlusion. Local sweat rates (SRs) on the forehead, chest, forearm, thigh and palm were continuously measured (ventilated capsule method). The forehead SR in prepubertal children during IH exercise at 45% MVC was significantly lower than that of young adults (0.26 ± 0.22 and 0.08 ± 0.15 mg cm -2  min -1 for young adults and children, respectively; P < 0.05) but not of the elderly at any exercise intensities. The SR on the chest (0.22 ± 0.22 and -0.01 ± 0.05 mg cm -2  min -1 for young adults and children, respectively), forearm (0.14 ± 0.12 and 0.03 ± 0.04 mg cm -2  min -1 ) and thigh (0.13 ± 0.10 and 0.02 ± 0.03 mg cm -2  min -1 ) during postexercise occlusion at 45% MVC was significantly lower in children than in young adults (P < 0.05). Elderly subjects showed a significantly lower SR on the forearm (0.04 ± 0.04 and 0.01 ± 0.02 mg cm -2  min -1 for young adults and elderly, respectively) and thigh (0.07 ± 0.07 and 0.01 ± 0.03 mg cm -2  min -1 ) at 15% MVC and on the thigh at 45% MVC (0.13 ± 0.10 and 0.04 ± 0.04 mg cm -2  min -1 ) during postexercise occlusion compared with young adults (P < 0.05). These results suggest that sweating responses to IH exercise and muscle metaboreflex were underdeveloped in prepubertal children and that ageing attenuates the response to the muscle metaboreflex in a way that is not consistent across the body. © 2016 The Authors. Experimental Physiology © 2016 The Physiological Society.

  10. How to prevent frostbite and hypothermia

    MedlinePlus

    Cold temperatures, wind, rain, and even sweat cool your skin and pull heat away from your body. You also lose heat ... inside your clothes Protect you from cold air, wind, snow, or rain Protect you from contact with ...

  11. Skin (image)

    MedlinePlus

    ... of the body. The skin and its derivatives (hair, nails, sweat and oil glands) make up the integumentary system. One of the main functions of the skin is protection. It protects the body from external factors such as bacteria, chemicals, and temperature.

  12. Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis

    DOE PAGES

    Gao, Wei; Emaminejad, Sam; Nyein, Hnin Yin Yin; ...

    2016-01-27

    We report that wearable sensor technologies are essential to the realization of personalized medicine through continuously monitoring an individual’s state of health. Sampling human sweat, which is rich in physiological information13, could enable non-invasive monitoring. Previously reported sweat-based and other noninvasive biosensors either can only monitor a single analyte at a time or lack on-site signal processing circuitry and sensor calibration mechanisms for accurate analysis of the physiological state14–18. Given the complexity of sweat secretion, simultaneous and multiplexed screening of target biomarkers is critical and requires full system integration to ensure the accuracy of measurements. Here we present a mechanicallymore » flexible and fully integrated (that is, no external analysis is needed) sensor array for multiplexed in situ perspiration analysis, which simultaneously and selectively measures sweat metabolites (such as glucose and lactate) and electrolytes (such as sodium and potassium ions), as well as the skin temperature (to calibrate the response of the sensors). Lastly, our work bridges the technological gap between signal transduction, conditioning (amplification and filtering), processing and wireless transmission in wearable biosensors by merging plasticbased sensors that interface with the skin with silicon integrated circuits consolidated on a flexible circuit board for complex signal processing.« less

  13. Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gao, Wei; Emaminejad, Sam; Nyein, Hnin Yin Yin

    We report that wearable sensor technologies are essential to the realization of personalized medicine through continuously monitoring an individual’s state of health. Sampling human sweat, which is rich in physiological information13, could enable non-invasive monitoring. Previously reported sweat-based and other noninvasive biosensors either can only monitor a single analyte at a time or lack on-site signal processing circuitry and sensor calibration mechanisms for accurate analysis of the physiological state14–18. Given the complexity of sweat secretion, simultaneous and multiplexed screening of target biomarkers is critical and requires full system integration to ensure the accuracy of measurements. Here we present a mechanicallymore » flexible and fully integrated (that is, no external analysis is needed) sensor array for multiplexed in situ perspiration analysis, which simultaneously and selectively measures sweat metabolites (such as glucose and lactate) and electrolytes (such as sodium and potassium ions), as well as the skin temperature (to calibrate the response of the sensors). Lastly, our work bridges the technological gap between signal transduction, conditioning (amplification and filtering), processing and wireless transmission in wearable biosensors by merging plasticbased sensors that interface with the skin with silicon integrated circuits consolidated on a flexible circuit board for complex signal processing.« less

  14. Phase II Testing of Liquid Cooling Garments Using a Sweating Manikin, Controlled by a Human Physiological Model

    NASA Technical Reports Server (NTRS)

    Paul, Heather; Trevino, Luis; Bue,Grant; Rugh, John

    2006-01-01

    An Advanced Automotive Manikin (ADAM) developed at the National Renewable Energy Laboratory (NREL) is used to evaluate NASA's liquid cooling garments (LCGs) used in advanced space suits for extravehicular applications. The manikin has 120 separate heated/sweating zones and is controlled by a finite element physiological model of the human thermoregulatory system. Previous testing showed the thermal sensation and comfort followed the expected trends as the LCG inlet fluid temperature was changed. The Phase II test data demonstrates the repeatability of ADAM by retesting the baseline LCG. Skin and core temperature predictions using ADAM in an LCG/Arctic suit combination are compared to NASA physiological data to validate the manikin/model. Additional LCG configurations are assessed using the manikin and compared to the baseline LCG. Results can extend to other personal protective clothing, including HAZMAT suits, nuclear/biological/chemical protective suits, and fire protection suits.

  15. Adaptation of exercise ventilation during an actively-induced hyperthermia following passive heat acclimation.

    PubMed

    Beaudin, Andrew E; Clegg, Miriam E; Walsh, Michael L; White, Matthew D

    2009-09-01

    Hyperthermia-induced hyperventilation has been proposed to be a human thermolytic thermoregulatory response and to contribute to the disproportionate increase in exercise ventilation (VE) relative to metabolic needs during high-intensity exercise. In this study it was hypothesized that VE would adapt similar to human eccrine sweating (E(SW)) following a passive heat acclimation (HA). All participants performed an incremental exercise test on a cycle ergometer from rest to exhaustion before and after a 10-day passive exposure for 2 h/day to either 50 degrees C and 20% relative humidity (RH) (n = 8, Acclimation group) or 24 degrees C and 32% RH (n = 4, Control group). Attainment of HA was confirmed by a significant decrease (P = 0.025) of the esophageal temperature (T(es)) threshold for the onset of E(SW) and a significantly elevated E(SW) (P < or = 0.040) during the post-HA exercise tests. HA also gave a significant decrease in resting T(es) (P = 0.006) and a significant increase in plasma volume (P = 0.005). Ventilatory adaptations during exercise tests following HA included significantly decreased T(es) thresholds (P < or = 0.005) for the onset of increases in the ventilatory equivalents for O(2) (VE/VO(2)) and CO(2) (VE/VCO(2)) and a significantly increased VE (P < or = 0.017) at all levels of T(es). Elevated VE was a function of a significantly greater tidal volume (P = 0.003) at lower T(es) and of breathing frequency (P < or = 0.005) at higher T(es). Following HA, the ventilatory threshold was uninfluenced and the relationships between VO(2) and either VE/VO(2) or VE/VCO(2) did not explain the resulting hyperventilation. In conclusion, the results support that exercise VE following passive HA responds similarly to E(SW), and the mechanism accounting for this adaptation is independent of changes of the ventilatory threshold or relationships between VO(2) with each of VE/VO(2) and VE/VCO(2).

  16. Facing up to the imperceptible perspiration. Modulatory influences by diabetic neuropathy, physical exercise and antiperspirant.

    PubMed

    Xhauflaire-Uhoda, Emmanuelle; Mayeux, Géraldine; Quatresooz, Pascale; Scheen, André; Piérard, Gérald E

    2011-11-01

    Sweating is variably altered by physical exercise, diabetic neuropathy and antiperspirants. Skin temperature, skin surface water loss (SSWL), the Corneometer(®) average capacitance (CMAC) and skin capacitance mapping (SCM) were measured before and after moderate physical exercise in 20 healthy subjects. The effect of 5% aluminium chloride hexahydrate (ACH) in a water solution was similarly tested. The same assessments were performed in 20 diabetic patients at rest. Diabetic neuropathy appeared at rest as an increased (compensatory) SCM on the forearms without obvious modification on the hypohidrotic legs. On ACH sites after exercise, SCM revealed both a lowered number of active sweat glands and a lighter stratum corneum (SC) (dryness). In addition, CMAC and SSWL were decreased on ACH sites at rest and at completion of exercise. In diabetic neuropathy, the compensatory hyperhidrosis is more easily disclosed than the hypohidrosis. ACH affects both sweat excretion and the SC hydration. © 2011 John Wiley & Sons A/S.

  17. Blood electrolytes and exercise in relation to temperature regulation in man.

    NASA Technical Reports Server (NTRS)

    Greenleaf, J. E.

    1973-01-01

    It is shown that the body temperature rise during physical exercise is a regulated process and is not due to a failure of heat-dissipating mechanisms. Core and skin temperatures do not provide sufficient information to account for the control of sweating during exercise. Evidence is presented that suggests an association between equilibrium levels of rectal temperature and the osmotic concentration of the blood with essentially no influence from variations in plasma volume.-

  18. Dynamic analysis of mental sweating of eccrine sweat gland of human fingertip by time-sequential piled-up en face optical coherence tomography images.

    PubMed

    Ohmi, Masato; Wada, Yuki

    2016-08-01

    In this paper, we demonstrate dynamic analysis of mental sweating for sound stimulus of a few tens of eccrine sweat glands by the time-sequential piled-up en face optical coherence tomography (OCT) images with the frame spacing of 3.3 sec. In the experiment, the amount of excess sweat can be evaluated simultaneously for a few tens of sweat glands by piling up of all the en face OCT images. Non-uniformity was observed in mental sweating where the amount of sweat in response to sound stimulus is different for each sweat gland. Furthermore, the amount of sweat is significantly increased in proportion to the strength of the stimulus.

  19. Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis.

    PubMed

    Gao, Wei; Emaminejad, Sam; Nyein, Hnin Yin Yin; Challa, Samyuktha; Chen, Kevin; Peck, Austin; Fahad, Hossain M; Ota, Hiroki; Shiraki, Hiroshi; Kiriya, Daisuke; Lien, Der-Hsien; Brooks, George A; Davis, Ronald W; Javey, Ali

    2016-01-28

    Wearable sensor technologies are essential to the realization of personalized medicine through continuously monitoring an individual's state of health. Sampling human sweat, which is rich in physiological information, could enable non-invasive monitoring. Previously reported sweat-based and other non-invasive biosensors either can only monitor a single analyte at a time or lack on-site signal processing circuitry and sensor calibration mechanisms for accurate analysis of the physiological state. Given the complexity of sweat secretion, simultaneous and multiplexed screening of target biomarkers is critical and requires full system integration to ensure the accuracy of measurements. Here we present a mechanically flexible and fully integrated (that is, no external analysis is needed) sensor array for multiplexed in situ perspiration analysis, which simultaneously and selectively measures sweat metabolites (such as glucose and lactate) and electrolytes (such as sodium and potassium ions), as well as the skin temperature (to calibrate the response of the sensors). Our work bridges the technological gap between signal transduction, conditioning (amplification and filtering), processing and wireless transmission in wearable biosensors by merging plastic-based sensors that interface with the skin with silicon integrated circuits consolidated on a flexible circuit board for complex signal processing. This application could not have been realized using either of these technologies alone owing to their respective inherent limitations. The wearable system is used to measure the detailed sweat profile of human subjects engaged in prolonged indoor and outdoor physical activities, and to make a real-time assessment of the physiological state of the subjects. This platform enables a wide range of personalized diagnostic and physiological monitoring applications.

  20. Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis

    NASA Astrophysics Data System (ADS)

    Gao, Wei; Emaminejad, Sam; Nyein, Hnin Yin Yin; Challa, Samyuktha; Chen, Kevin; Peck, Austin; Fahad, Hossain M.; Ota, Hiroki; Shiraki, Hiroshi; Kiriya, Daisuke; Lien, Der-Hsien; Brooks, George A.; Davis, Ronald W.; Javey, Ali

    2016-01-01

    Wearable sensor technologies are essential to the realization of personalized medicine through continuously monitoring an individual’s state of health. Sampling human sweat, which is rich in physiological information, could enable non-invasive monitoring. Previously reported sweat-based and other non-invasive biosensors either can only monitor a single analyte at a time or lack on-site signal processing circuitry and sensor calibration mechanisms for accurate analysis of the physiological state. Given the complexity of sweat secretion, simultaneous and multiplexed screening of target biomarkers is critical and requires full system integration to ensure the accuracy of measurements. Here we present a mechanically flexible and fully integrated (that is, no external analysis is needed) sensor array for multiplexed in situ perspiration analysis, which simultaneously and selectively measures sweat metabolites (such as glucose and lactate) and electrolytes (such as sodium and potassium ions), as well as the skin temperature (to calibrate the response of the sensors). Our work bridges the technological gap between signal transduction, conditioning (amplification and filtering), processing and wireless transmission in wearable biosensors by merging plastic-based sensors that interface with the skin with silicon integrated circuits consolidated on a flexible circuit board for complex signal processing. This application could not have been realized using either of these technologies alone owing to their respective inherent limitations. The wearable system is used to measure the detailed sweat profile of human subjects engaged in prolonged indoor and outdoor physical activities, and to make a real-time assessment of the physiological state of the subjects. This platform enables a wide range of personalized diagnostic and physiological monitoring applications.

  1. A Real-Time Wireless Sweat Rate Measurement System for Physical Activity Monitoring.

    PubMed

    Brueck, Andrew; Iftekhar, Tashfin; Stannard, Alicja B; Yelamarthi, Kumar; Kaya, Tolga

    2018-02-10

    There has been significant research on the physiology of sweat in the past decade, with one of the main interests being the development of a real-time hydration monitor that utilizes sweat. The contents of sweat have been known for decades; sweat provides significant information on the physiological condition of the human body. However, it is important to know the sweat rate as well, as sweat rate alters the concentration of the sweat constituents, and ultimately affects the accuracy of hydration detection. Towards this goal, a calorimetric based flow-rate detection system was built and tested to determine sweat rate in real time. The proposed sweat rate monitoring system has been validated through both controlled lab experiments (syringe pump) and human trials. An Internet of Things (IoT) platform was embedded, with the sensor using a Simblee board and Raspberry Pi. The overall prototype is capable of sending sweat rate information in real time to either a smartphone or directly to the cloud. Based on a proven theoretical concept, our overall system implementation features a pioneer device that can truly measure the rate of sweat in real time, which was tested and validated on human subjects. Our realization of the real-time sweat rate watch is capable of detecting sweat rates as low as 0.15 µL/min/cm², with an average error in accuracy of 18% compared to manual sweat rate readings.

  2. Effects of isotonic and isometric exercises with mist sauna bathing on cardiovascular, thermoregulatory, and metabolic functions

    NASA Astrophysics Data System (ADS)

    Iwase, Satoshi; Kawahara, Yuko; Nishimura, Naoki; Nishimura, Rumiko; Sugenoya, Junichi; Miwa, Chihiro; Takada, Masumi

    2014-08-01

    To clarify the effects of isometric and isotonic exercise during mist sauna bathing on the cardiovascular function, thermoregulatory function, and metabolism, six healthy young men (22 ± 1 years old, height 173 ± 4 cm, weight 65.0 ± 5.0 kg) were exposed to a mist sauna for 10 min at a temperature of 40 °C, and relative humidity of 100 % while performing or not performing ˜30 W of isometric or isotonic exercise. The effect of the exercise was assessed by measuring tympanic temperature, heart rate, systolic and diastolic blood pressure, chest sweat rate, chest skin blood flow, and plasma catecholamine and cortisol, glucose, lactate, and free fatty acid levels. Repeated measures ANOVA showed no significant differences in blood pressure, skin blood flow, sweat rate, and total amount of sweating. Tympanic temperature increased more during isotonic exercise, and heart rate increase was more marked during isotonic exercise. The changes in lactate indicated that fatigue was not very great during isometric exercise. The glucose level indicated greater energy expenditure during isometric exercise. The free fatty acid and catecholamine levels indicated that isometric exercise did not result in very great energy expenditure and stress, respectively. The results for isotonic exercise of a decrease in lactate level and an increase in plasma free fatty acid level indicated that fatigue and energy expenditure were rather large while the perceived stress was comparatively low. We concluded that isotonic exercise may be a more desirable form of exercise during mist sauna bathing given the changes in glucose and free fatty acid levels.

  3. Measured impacts of supermarket humidity level on defrost performance and refrigerating system energy use

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Henderson, H.I.; Khattar, M.

    This paper presents field-monitor data from two supermarkets where the impact of space humidity on refrigerating system energy use was evaluated. Direct digital control (DDC) systems were used at both stores to collect 15-minute monitored data. At Store A in Minneapolis, the DDC system was used to monitor system performance as well as to implement temperature-terminated control in place of time-terminated control on 16 refrigerated zones using hot gas defrost. At Store B in Indianapolis, the DDC system was used to quantify the performance trends for the single compressor rack system with electric defrost. The results at Store B showedmore » that refrigerating system energy use decreases by nearly 10 kWh/day for each 1% drop in space relative humidity, or about 0.4% of average annual system energy use. This value includes the impact of reduced latent loads, the reduction in direct energy use and imposed load from reduced electric defrost heater operation, and the smaller imposed load from reduced anti-sweat heater energy use. The measured reductions agree well with the impact predicted using the calculation methods developed by Howell (1933b) in ASHRAE Research Project 596. At Store A, the measured data show that implementing temperature-terminated defrost reduced refrigerating system energy use by nearly 70 kWh/day over the winter period when the average space humidity was 22% RH. The savings from temperature-terminated defrost increase by 4 kWh/day per each 1% drop in relative humidity. At both stores, the same type of mechanical controls were used to duty cycle the anti-sweat heaters based on store dew point. Anti-sweat heater electricity use was observed to decrease by 4.6 kWh/day at Store B and 3.4 kWh/day at Store A for each 1% drop in relative humidity. At Store A, a more aggressive control scheme was implemented with the DDC system that reduced anti-sweat heater energy use by 7.8 kWh/day per % RH. The more aggressive control approach was reported to properly control fogging and condensation on display case surfaces. The overall energy reduction factor at the two stores was 12 kWh/day per % RH at Store A and 15 kWh/day per % RH at Store B. With more aggressive anti-sweat heater control, reduction factors as high as 20 kWh/day per % RH appear to be possible.« less

  4. Increased Air Velocity Reduces Thermal and Cardiovascular Strain in Young and Older Males during Humid Exertional Heat Stress.

    PubMed

    Wright Beatty, Heather E; Hardcastle, Stephen G; Boulay, Pierre; Flouris, Andreas D; Kenny, Glen P

    2015-01-01

    Older adults have been reported to have a lower evaporative heat loss capacity than younger adults during exercise when full sweat evaporation is permitted. However, it is unclear how conditions of restricted evaporative and convective heat loss (i.e., high humidity, clothing insulation) alter heat stress. to the purpose of this study was to examine the heat stress responses of young and older males during and following exercise in a warm/humid environment under two different levels of air velocity. Ten young (YOUNG: 24±2 yr) and 10 older (OLDER: 59±3 yr) males, matched for body surface area performed 4×15-min cycling bouts (15-min rest) at a fixed rate of heat production (400 W) in warm/humid conditions (35°C, 60% relative humidity) under 0.5 (Low) and 3.0 (High) m·s(-1) air velocity while wearing work coveralls. Rectal (Tre) and mean skin (MTsk) temperatures, heart rate (HR), local sweat rate, % max skin blood flow (SkBF) (recovery only), and blood pressure (recovery only) were measured. High air velocity reduced core and skin temperatures (p < 0.05) equally in YOUNG and OLDER males (p > 0.05) but was more effective in reducing cardiovascular strain (absolute and % max HR; p < 0.05) in YOUNG males (p < 0.05). Greater increases in local dry heat loss responses (% max SkBF and cutaneous vascular conductance) were detected across time in OLDER than YOUNG males in both conditions (p < 0.05). Local dry heat loss responses and cardiovascular strain were attenuated during the High condition in YOUNG compared to OLDER (p < 0.05). High air velocity reduced the number of males surpassing the 38.0°C Tre threshold from 90% (Low) to 50% (High). Despite age-related local heat loss differences, YOUNG and OLDER males had similar levels of heat stress during intermittent exercise in warm and humid conditions while wearing work coveralls. Increased air velocity was effective in reducing heat stress equally, and cardiovascular strain to a greater extent, in YOUNG and OLDER males, and may be useful for mitigating heat stress in all workers.

  5. Diagnosis of cystic fibrosis with chloride meter (Sherwood M926S chloride analyzer®) and sweat test analysis system (CFΔ collection system®) compared to the Gibson Cooke method.

    PubMed

    Emiralioğlu, Nagehan; Özçelik, Uğur; Yalçın, Ebru; Doğru, Deniz; Kiper, Nural

    2016-01-01

    Sweat test with Gibson Cooke (GC) method is the diagnostic gold standard for cystic fibrosis (CF). Recently, alternative methods have been introduced to simplify both the collection and analysis of sweat samples. Our aim was to compare sweat chloride values obtained by GC method with other sweat test methods in patients diagnosed with CF and whose CF diagnosis had been ruled out. We wanted to determine if the other sweat test methods could reliably identify patients with CF and differentiate them from healthy subjects. Chloride concentration was measured with GC method, chloride meter and sweat test analysis system; also conductivity was determined with sweat test analysis system. Forty eight patients with CF and 82 patients without CF underwent the sweat test, showing median sweat chloride values 98.9 mEq/L with GC method, 101 mmol/L with chloride meter, 87.8 mmol/L with sweat test analysis system. In non-CF group, median sweat chloride values were 16.8 mEq/L with GC method, 10.5 mmol/L with chloride meter, and 15.6 mmol/L with sweat test analysis system. Median conductivity value was 107.3 mmol/L in CF group and 32.1 mmol/L in non CF group. There was a strong positive correlation between GC method and the other sweat test methods with a statistical significance (r=0.85) in all subjects. Sweat chloride concentration and conductivity by other sweat test methods highly correlate with the GC method. We think that the other sweat test equipments can be used as reliably as the classic GC method to diagnose or exclude CF.

  6. Sweating Rate and Sweat Sodium Concentration in Athletes: A Review of Methodology and Intra/Interindividual Variability.

    PubMed

    Baker, Lindsay B

    2017-03-01

    Athletes lose water and electrolytes as a consequence of thermoregulatory sweating during exercise and it is well known that the rate and composition of sweat loss can vary considerably within and among individuals. Many scientists and practitioners conduct sweat tests to determine sweat water and electrolyte losses of athletes during practice and competition. The information gleaned from sweat testing is often used to guide personalized fluid and electrolyte replacement recommendations for athletes; however, unstandardized methodological practices and challenging field conditions can produce inconsistent/inaccurate results. The primary objective of this paper is to provide a review of the literature regarding the effect of laboratory and field sweat-testing methodological variations on sweating rate (SR) and sweat composition (primarily sodium concentration [Na + ]). The simplest and most accurate method to assess whole-body SR is via changes in body mass during exercise; however, potential confounding factors to consider are non-sweat sources of mass change and trapped sweat in clothing. In addition, variability in sweat [Na + ] can result from differences in the type of collection system used (whole body or localized), the timing/duration of sweat collection, skin cleaning procedure, sample storage/handling, and analytical technique. Another aim of this paper is to briefly review factors that may impact intra/interindividual variability in SR and sweat [Na + ] during exercise, including exercise intensity, environmental conditions, heat acclimation, aerobic capacity, body size/composition, wearing of protective equipment, sex, maturation, aging, diet, and/or hydration status. In summary, sweat testing can be a useful tool to estimate athletes' SR and sweat Na + loss to help guide fluid/electrolyte replacement strategies, provided that data are collected, analyzed, and interpreted appropriately.

  7. Limited social plasticity in the socially polymorphic sweat bee Lasioglossum calceatum.

    PubMed

    Davison, P J; Field, J

    2018-01-01

    Eusociality is characterised by a reproductive division of labour, where some individuals forgo direct reproduction to instead help raise kin. Socially polymorphic sweat bees are ideal models for addressing the mechanisms underlying the transition from solitary living to eusociality, because different individuals in the same species can express either eusocial or solitary behaviour. A key question is whether alternative social phenotypes represent environmentally induced plasticity or predominantly genetic differentiation between populations. In this paper, we focus on the sweat bee Lasioglossum calceatum , in which northern or high-altitude populations are solitary, whereas more southern or low-altitude populations are typically eusocial. To test whether social phenotype responds to local environmental cues, we transplanted adult females from a solitary, northern population, to a southern site where native bees are typically eusocial. Nearly all native nests were eusocial, with foundresses producing small first brood (B1) females that became workers. In contrast, nine out of ten nests initiated by transplanted bees were solitary, producing female offspring that were the same size as the foundress and entered directly into hibernation. Only one of these ten nests became eusocial. Social phenotype was unlikely to be related to temperature experienced by nest foundresses when provisioning B1 offspring, or by B1 emergence time, both previously implicated in social plasticity seen in two other socially polymorphic sweat bees. Our results suggest that social polymorphism in L. calceatum predominantly reflects genetic differentiation between populations, and that plasticity is in the process of being lost by bees in northern populations. Phenotypic plasticity is thought to play a key role in the early stages of the transition from solitary to eusocial behaviour, but may then be lost if environmental conditions become less variable. Socially polymorphic sweat bees exhibit either solitary or eusocial behaviour in different geographic populations, depending on the length of the nesting season. We tested for plasticity in the socially polymorphic sweat bee Lasioglossum calceatum by transplanting nest foundresses from a northern, non-eusocial population to a southern, eusocial population. Plasticity would be detected if transplanted bees exhibited eusocial behaviour. We found that while native bees were eusocial, 90% of transplanted bees and their offspring did not exhibit traits associated with eusociality. Environmental variables such as time of offspring emergence or temperatures experienced by foundresses during provisioning could not explain these differences. Our results suggest that the ability of transplanted bees to express eusociality is being lost, and that social polymorphism predominantly reflects genetic differences between populations.

  8. Water and salt balance in young male football players in training during the holy month of Ramadan.

    PubMed

    Shirreffs, Susan M; Maughan, Ronald J

    2008-12-01

    The aim of this study was to assess water and salt balance in young football players in training during Ramadan. Measurements were made in 92 young male football players before and during the month of Ramadan. Fifty-five participants were observing Ramadan fasting, while the other 37 participants were eating and drinking without restriction. In week 3 of Ramadan, water and salt balance measures were made during a training session of 60-70 min duration that was performed at an ambient temperature of 25-28 degrees C and relative humidity of 50-53%. Body mass was recorded before and after training. Fluid intake was assessed in non-fasting players by weighing drink bottles before and after training, and the volume of any urine output was recorded. Sweat composition was estimated from absorbent patches applied to four skin sites for the duration of training. Mean sweat loss of players amounted to 1.41 litres (s = 0.36) in fasting players and 1.61 litres (s = 0.51) in non-fasting players (P = 0.038). Mean fluid intake during training in non-fasting players was 1.92 litres (s = 0.66). Sweat sodium concentration was 20 mmol . l(-1) (s = 8) in fasting players and 17 mmol . l(-1) (s = 7) in non-fasting players, and total sweat sodium loss during training was 0.67 g (s = 0.41) and 0.65 g (s = 0.37) [corresponding to a salt loss of 1.7 g (s = 1.1) and 1.7 g (s = 0.9)] respectively, with no difference between fasting and non-fasting players. Sweat sodium loss was not related to estimated dietary sodium intake (r = -0.07). These descriptive data show large individual variations in all measured parameters with relatively little difference in sweat parameters between fasting and non-fasting individuals.

  9. Expanded prediction equations of human sweat loss and water needs.

    PubMed

    Gonzalez, R R; Cheuvront, S N; Montain, S J; Goodman, D A; Blanchard, L A; Berglund, L G; Sawka, M N

    2009-08-01

    The Institute of Medicine expressed a need for improved sweating rate (msw) prediction models that calculate hourly and daily water needs based on metabolic rate, clothing, and environment. More than 25 years ago, the original Shapiro prediction equation (OSE) was formulated as msw (g.m(-2).h(-1))=27.9.Ereq.(Emax)(-0.455), where Ereq is required evaporative heat loss and Emax is maximum evaporative power of the environment; OSE was developed for a limited set of environments, exposures times, and clothing systems. Recent evidence shows that OSE often overpredicts fluid needs. Our study developed a corrected OSE and a new msw prediction equation by using independent data sets from a wide range of environmental conditions, metabolic rates (rest to 500 observations) by using a variety of metabolic rates over a range of environmental conditions (ambient temperature, 15-46 degrees C; water vapor pressure, 0.27-4.45 kPa; wind speed, 0.4-2.5 m/s), clothing, and equipment combinations and durations (2-8 h). Data are expressed as grams per square meter per hour and were analyzed using fuzzy piecewise regression. OSE overpredicted sweating rates (P<0.003) compared with observed msw. Both the correction equation (OSEC), msw=147.exp (0.0012.OSE), and a new piecewise (PW) equation, msw=147+1.527.Ereq-0.87.Emax were derived, compared with OSE, and then cross-validated against independent data (21 males and 9 females; >200 observations). OSEC and PW were more accurate predictors of sweating rate (58 and 65% more accurate, P<0.01) and produced minimal error (standard error estimate<100 g.m(-2).h(-1)) for conditions both within and outside the original OSE domain of validity. The new equations provide for more accurate sweat predictions over a broader range of conditions with applications to public health, military, occupational, and sports medicine settings.

  10. Activation of autonomic thermoeffectors preceding the decision to behaviourally thermoregulate in resting humans.

    PubMed

    Schlader, Zachary J; Coleman, Gregory L; Sackett, James R; Sarker, Suman; Chapman, Christopher L; Johnson, Blair D

    2016-07-12

    What is the central question of this study? Do increases in metabolic heat production and sweat rate precede the initiation of thermoregulatory behaviour in resting humans exposed to cool and warm environments? What is the main finding and its importance? Thermoregulatory behaviour at rest in cool and warm environments is preceded by changes in vasomotor tone in glabrous and non-glabrous skin, but not by acute increases in metabolic heat production or sweat rate. These findings suggest that sweating and shivering are not obligatory for thermal behaviour to be initiated in humans. We tested the hypothesis that acute increases in metabolic heat production and sweating precede the initiation of thermoregulatory behaviour in resting humans exposed to cool and warm environments. Twelve healthy young subjects passively moved between 17 and 40°C rooms when they felt 'too cool' (C→W) or 'too warm' (W→C). Skin and internal (intestinal) temperatures, metabolic heat production, local sweat rate (forearm and chest) and cutaneous vascular conductance (CVC; forearm and fingertip) were measured continually. Compared with pretest baseline (31.8 ± 0.3°C), skin temperature was higher at C→W (32.0 ± 0.7°C; P = 0.01) and W→C (34.5 ± 0.5°C; P < 0.01). Internal temperature did not differ (P = 0.12) between baseline (37.2 ± 0.3°C), C→W (37.2 ± 0.3°C) and W→C (37.0 ± 0.3°C). Metabolic heat production was not different from baseline (40 ± 9 W m -2 ) at C→W (39 ± 7 W m -2 ; P = 0.50). Forearm (0.06 ± 0.01 mg cm -2  min -1 ) and chest (0.04 ± 0.02 mg cm -2  min -1 ) sweat rate at W→C did not differ from baseline (forearm, 0.05 ± 0.02 mg cm -2  min -1 and chest, 0.04 ± 0.02 mg cm -2  min -1 ; P ≥ 0.23). Forearm CVC was not different from baseline (0.30 ± 0.21 perfusion units (PU) mmHg -1 ) at C→W (0.24 ± 0.11 PU mmHg -1 ; P = 0.17), but was higher at W→C (0.65 ± 0.33 PU mmHg -1 ; P < 0.01). Fingertip CVC was different from baseline (2.6 ± 2.0 PU mmHg -1 ) at C→W (0.70 ± 0.42 PU mmHg -1 ; P < 0.01) and W→C (4.49 ± 1.66 PU mmHg -1 ; P < 0.01). Thermoregulatory behaviour at rest in cool and warm environments is preceded by changes in vasomotor tone in glabrous and non-glabrous skin, but not by acute increases in metabolic heat production or sweat rate. © 2016 The Authors. Experimental Physiology © 2016 The Physiological Society.

  11. A Real-Time Wireless Sweat Rate Measurement System for Physical Activity Monitoring

    PubMed Central

    Brueck, Andrew; Iftekhar, Tashfin; Stannard, Alicja B.; Kaya, Tolga

    2018-01-01

    There has been significant research on the physiology of sweat in the past decade, with one of the main interests being the development of a real-time hydration monitor that utilizes sweat. The contents of sweat have been known for decades; sweat provides significant information on the physiological condition of the human body. However, it is important to know the sweat rate as well, as sweat rate alters the concentration of the sweat constituents, and ultimately affects the accuracy of hydration detection. Towards this goal, a calorimetric based flow-rate detection system was built and tested to determine sweat rate in real time. The proposed sweat rate monitoring system has been validated through both controlled lab experiments (syringe pump) and human trials. An Internet of Things (IoT) platform was embedded, with the sensor using a Simblee board and Raspberry Pi. The overall prototype is capable of sending sweat rate information in real time to either a smartphone or directly to the cloud. Based on a proven theoretical concept, our overall system implementation features a pioneer device that can truly measure the rate of sweat in real time, which was tested and validated on human subjects. Our realization of the real-time sweat rate watch is capable of detecting sweat rates as low as 0.15 µL/min/cm2, with an average error in accuracy of 18% compared to manual sweat rate readings. PMID:29439398

  12. Quality of sweat test (ST) based on the proportion of sweat sodium (Na) and sweat chloride (Cl) as diagnostic parameter of cystic fibrosis: are we on the right way?

    PubMed

    Faria, Alethéa Guimarães; Marson, Fernando Augusto Lima; Gomez, Carla Cristina de Souza; Ribeiro, Maria Ângela Gonçalves de Oliveira; Morais, Lucas Brioschi; Servidoni, Maria de Fátima; Bertuzzo, Carmen Sílvia; Sakano, Eulália; Goto, Maura; Paschoal, Ilma Aparecida; Pereira, Mônica Corso; Hessel, Gabriel; Levy, Carlos Emílio; Toro, Adyléia Aparecida Dalbo Contrera; Peixoto, Andressa Oliveira; Simões, Maria Cristina Ribeiro; Lomazi, Elizete Aparecida; Nogueira, Roberto José Negrão; Ribeiro, Antônio Fernando; Ribeiro, José Dirceu

    2016-10-26

    To assess the quality of sweat test (ST) based on the proportion of sweat sodium and sweat chloride as diagnostic parameter of cystic fibrosis (CF). A retrospective study of 5,721 sweat samples and subsequent descriptive analysis were carried out. The test was considered "of good quality" (correct) when: (i) sweat chloride was lower than 60 mEq/L, and sweat sodium was higher than sweat chloride; (ii) sweat chloride was higher than 60 mEq/L, and sweat sodium was lower than sweat chloride. The study included 5,692/5,721 sweat samples of ST which had been requested due to clinical presentations compatible with CF and/or neonatal screenings with altered immunoreactive trypsinogen values. Considering the proportion of sweat sodium and sweat chloride as ST quality parameter, the test was performed correctly in 5,023/5,692 (88.2 %) sweat samples. The sweat chloride test results were grouped into four reference ranges for chloride (i) chloride < 30 mEq/L: 3,651/5,692 (64.1 %); (ii) chloride ≥ 30 mEq/L to < 40 mEq/L: 652/5,692 (11.5 %); (iii) ≥ 40 mEq/L to < 60 mEq/L: 673/5,692 (11.8 %); (iv) ≥ 60 mEq/L: 716/5,692 (12.6 %). In the comparative analysis, there was no association between ST quality and: (i) symptoms to indicate a ST [respiratory (p = 0.084), digestive (p = 0.753), nutritional (p = 0.824), and others (p = 0.136)], (ii) sweat weight (p = 0.416). However, there was a positive association with: (i) gender, (ii) results of ST (p < 0.001), (iii) chloride/sodium ratio (p < 0.001), (iv) subject's age at the time of ST [grouped according to category (p < 0.001) and numerical order (p < 0.001)]. For the subset of 169 patients with CF and two CFTR mutations Class I, II and/or III, in comparative analysis, there was a positive association with: (i) sweat chloride/sodium ratio (p < 0.001), (ii) sweat chloride values (p = 0.047), (iii) subject's age at the time of the ST grouped by numerical order (p = 0.001). Considering that the quality of ST can be assessed by levels of sweat sodium and sweat chloride, an increasing number of low-quality tests could be observed in our sweat samples. The quality of the test was associated with important factors, such as gender, CF diagnosis, and subjects' age.

  13. Modeling heat exchange characteristics of long term space operations: Role of skin wettedness and exercise

    NASA Technical Reports Server (NTRS)

    Gonzalez, Richard R.

    1994-01-01

    The problems of heat exchange during rest and exercise during long term space operations are covered in this report. Particular attention is given to the modeling and description of the consequences of requirement to exercise in a zero-g atmosphere during Space Shuttle flights, especially long term ones. In space environments, there exists no free convection therefore only forced convection occurring by movement, such as pedalling on a cycle ergometer, augments required heat dissipation necessary to regulate body temperature. The requirement to exercise at discrete periods of the day is good practice in order to resist the deleterious consequences of zero-gravity problems and improve distribution of body fluids. However, during exercise (ca. 180 to 250W), in zero-g environments, the mass of eccrine sweating rests as sheets on the skin surface and the sweat cannot evaporate readily. The use of exercise suits with fabrics that have hydrophobic or outwicking properties somewhat distributes the mass of sweat to a larger surface from which to evaporate. However, with no free convection, increased skin wettedness throughout the body surface induces increasing thermal discomfort, particularly during continuous exercise. This report presents several alternatives to aid in this problem: use of intermittent exercise, methods to quantify local skin wettedness, and introduction of a new effective temperature that integrates thermal stress and heat exchange avenues in a zero-g atmosphere.

  14. Effect of salt supplementation on the rate of inadequate sweat collection for infants less than 3 months of age referred for the sweat test.

    PubMed

    Guglani, Lokesh; Abdulhamid, Ibrahim

    2015-01-01

    Sweat testing in young infants (≤ 3 months) with a positive newborn screen for Cystic Fibrosis (CF) can yield higher rates of inadequate sweat collection. The role of salt supplements in improving sweat collection has not been studied before. All young infants referred to our CF center for sweat testing were randomized to either receive salt supplements {1/8th teaspoon salt (750 mg)} mixed in formula feeds 1 day prior to sweat testing (study group) or no salt supplement (controls). Of the 151 young infants that underwent sweat testing over 18 months, 75 received salt supplements, while 76 did not. A total of 9 (11.8%) infants in the salt supplement group had inadequate sweat collection, as compared to 4 (5.2%) infants in the control group (p = 0.16, Fisher's Exact Test). Oral salt supplementation for young infants prior to sweat testing does not help to reduce the rates of inadequate sweat collection.

  15. Sweat, the driving force behind normal skin: an emerging perspective on functional biology and regulatory mechanisms.

    PubMed

    Murota, Hiroyuki; Matsui, Saki; Ono, Emi; Kijima, Akiko; Kikuta, Junichi; Ishii, Masaru; Katayama, Ichiro

    2015-01-01

    The various symptoms associated with excessive or insufficient perspiration can significantly reduce a patient's quality of life. If a versatile and minimally invasive method could be established for returning sweat activity to normalcy, there is no question that it could be used in the treatment of many diseases that are believed to involve perspiration. For this reason, based on an understanding of the sweat-gland control function and sweat activity, it was necessary to conduct a comprehensive search for the factors that control sweating, such as the central and peripheral nerves that control sweat-gland function, the microenvironment surrounding the sweat glands, and lifestyle. We focused on the mechanism by which atopic dermatitis leads to hypohidrosis and confirmed that histamine inhibits acetylcholinergic sweating. Acetylcholine promotes the phosphorylation of glycogen synthesis kinase 3β (GSK3β) in the sweat-gland secretory cells and leads to sensible perspiration. By suppressing the phosphorylation of GSK3β, histamine inhibits the movement of sweat from the sweat-gland secretory cells through the sweat ducts, which could presumably be demonstrated by dynamic observations of the sweat glands using two-photon microscopy. It is expected that the discovery of new factors that control sweat-gland function can contribute to the treatment of diseases associated with dyshidrosis. Copyright © 2014 Japanese Society for Investigative Dermatology. Published by Elsevier Ireland Ltd. All rights reserved.

  16. Sweat

    MedlinePlus

    Sweat is a clear, salty liquid produced by glands in your skin. Sweating is how your body cools itself. You sweat mainly under your arms and on your feet and palms. When sweat mixes with bacteria on your skin, it can ...

  17. What's Sweat?

    MedlinePlus

    ... Safe Videos for Educators Search English Español What's Sweat? KidsHealth / For Kids / What's Sweat? Print en español ¿ ... dehydrated (say: dee-HI-drayt-ed). Why Does Sweat Smell? Sweat isn't just wet — it can ...

  18. Eccrine Sweat Contains IL-1α, IL-1β and IL-31 and Activates Epidermal Keratinocytes as a Danger Signal

    PubMed Central

    Dai, Xiuju; Okazaki, Hidenori; Hanakawa, Yasushi; Murakami, Masamoto; Tohyama, Mikiko; Shirakata, Yuji; Sayama, Koji

    2013-01-01

    Eccrine sweat is secreted onto the skin's surface and is not harmful to normal skin, but can exacerbate eczematous lesions in atopic dermatitis. Although eccrine sweat contains a number of minerals, proteins, and proteolytic enzymes, how it causes skin inflammation is not clear. We hypothesized that it stimulates keratinocytes directly, as a danger signal. Eccrine sweat was collected from the arms of healthy volunteers after exercise, and levels of proinflammatory cytokines in the sweat were quantified by ELISA. We detected the presence of IL-1α, IL-1β, and high levels of IL-31 in sweat samples. To investigate whether sweat activates keratinocytes, normal human keratinocytes were stimulated with concentrated sweat. Western blot analysis demonstrated the activation of NF-κB, ERK, and JNK signaling in sweat-stimulated keratinocytes. Real-time PCR using total RNA and ELISA analysis of supernatants showed the upregulation of IL-8 and IL-1β by sweat. Furthermore, pretreatment with IL-1R antagonist blocked sweat-stimulated cytokine production and signal activation, indicating that bioactive IL-1 is a major factor in the activation of keratinocytes by sweat. Moreover, IL-31 seems to be another sweat stimulator that activates keratinocytes to produce inflammatory cytokine, CCL2. Sweat is secreted onto the skin's surface and does not come into contact with keratinocytes in normal skin. However, in skin with a defective cutaneous barrier, such as atopic dermatitis-affected skin, sweat cytokines can directly act on epidermal keratinocytes, resulting in their activation. In conclusion, eccrine sweat contains proinflammatory cytokines, IL-1 and IL-31, and activates epidermal keratinocytes as a danger signal. PMID:23874436

  19. Pituitary adenylate cyclase-activating polypeptide promotes eccrine gland sweat secretion.

    PubMed

    Sasaki, S; Watanabe, J; Ohtaki, H; Matsumoto, M; Murai, N; Nakamachi, T; Hannibal, J; Fahrenkrug, J; Hashimoto, H; Watanabe, H; Sueki, H; Honda, K; Miyazaki, A; Shioda, S

    2017-02-01

    Sweat secretion is the major function of eccrine sweat glands; when this process is disturbed (paridrosis), serious skin problems can arise. To elucidate the causes of paridrosis, an improved understanding of the regulation, mechanisms and factors underlying sweat production is required. Pituitary adenylate cyclase-activating polypeptide (PACAP) exhibits pleiotropic functions that are mediated via its receptors [PACAP-specific receptor (PAC1R), vasoactive intestinal peptide (VIP) receptor type 1 (VPAC1R) and VPAC2R]. Although some studies have suggested a role for PACAP in the skin and several exocrine glands, the effects of PACAP on the process of eccrine sweat secretion have not been examined. To investigate the effect of PACAP on eccrine sweat secretion. Reverse transcriptase-polymerase chain reaction and immunostaining were used to determine the expression and localization of PACAP and its receptors in mouse and human eccrine sweat glands. We injected PACAP subcutaneously into the footpads of mice and used the starch-iodine test to visualize sweat-secreting glands. Immunostaining showed PACAP and PAC1R expression by secretory cells from mouse and human sweat glands. PACAP immunoreactivity was also localized in nerve fibres around eccrine sweat glands. PACAP significantly promoted sweat secretion at the injection site, and this could be blocked by the PAC1R-antagonist PACAP6-38. VIP, an agonist of VPAC1R and VPAC2R, failed to induce sweat secretion. This is the first report demonstrating that PACAP may play a crucial role in sweat secretion via its action on PAC1R located in eccrine sweat glands. The mechanisms underlying the role of PACAP in sweat secretion may provide new therapeutic options to combat sweating disorders. © 2016 British Association of Dermatologists.

  20. Sweat Facilitated Amino Acid Losses in Male Athletes during Exercise at 32-34°C.

    PubMed

    Dunstan, R Hugh; Sparkes, Diane L; Dascombe, Benjamin J; Macdonald, Margaret M; Evans, Craig A; Stevens, Christopher J; Crompton, Marcus J; Gottfries, Johan; Franks, Jesse; Murphy, Grace; Wood, Ryan; Roberts, Timothy K

    2016-01-01

    Sweat contains amino acids and electrolytes derived from plasma and athletes can lose 1-2L of sweat per hour during exercise. Sweat may also contain contributions of amino acids as well as urea, sodium and potassium from the natural moisturizing factors (NMF) produced in the stratum corneum. In preliminary experiments, one participant was tested on three separate occasions to compare sweat composition with surface water washings from the same area of skin to assess contributions from NMF. Two participants performed a 40 minute self-paced cycle session with sweat collected from cleansed skin at regular intervals to assess the contributions to the sweat load from NMF over the period of exercise. The main study investigated sweat amino acid composition collected from nineteen male athletes following standardised endurance exercise regimes at 32-34°C and 20-30% RH. Plasma was also collected from ten of the athletes to compare sweat and plasma composition of amino acids. The amino acid profiles of the skin washings were similar to the sweat, suggesting that the NMF could contribute certain amino acids into sweat. Since the sweat collected from athletes contained some amino acid contributions from the skin, this fluid was subsequently referred to as "faux" sweat. Samples taken over 40 minutes of exercise showed that these contributions diminished over time and were minimal at 35 minutes. In the main study, the faux sweat samples collected from the athletes with minimal NMF contributions, were characterised by relatively high levels of serine, histidine, ornithine, glycine and alanine compared with the corresponding levels measured in the plasma. Aspartic acid was detected in faux sweat but not in the plasma. Glutamine and proline were lower in the faux sweat than plasma in all the athletes. Three phenotypic groups of athletes were defined based on faux sweat volumes and composition profiles of amino acids with varying relative abundances of histidine, serine, glycine and ornithine. It was concluded that for some individuals, faux sweat resulting from exercise at 32-34°C and 20-30% RH posed a potentially significant source of amino acid loss.

  1. Sweat Facilitated Amino Acid Losses in Male Athletes during Exercise at 32-34°C

    PubMed Central

    Dunstan, R. Hugh; Sparkes, Diane L.; Dascombe, Benjamin J.; Macdonald, Margaret M.; Evans, Craig A.; Stevens, Christopher J.; Crompton, Marcus J.; Gottfries, Johan; Franks, Jesse; Murphy, Grace; Wood, Ryan; Roberts, Timothy K.

    2016-01-01

    Sweat contains amino acids and electrolytes derived from plasma and athletes can lose 1-2L of sweat per hour during exercise. Sweat may also contain contributions of amino acids as well as urea, sodium and potassium from the natural moisturizing factors (NMF) produced in the stratum corneum. In preliminary experiments, one participant was tested on three separate occasions to compare sweat composition with surface water washings from the same area of skin to assess contributions from NMF. Two participants performed a 40 minute self-paced cycle session with sweat collected from cleansed skin at regular intervals to assess the contributions to the sweat load from NMF over the period of exercise. The main study investigated sweat amino acid composition collected from nineteen male athletes following standardised endurance exercise regimes at 32–34°C and 20–30% RH. Plasma was also collected from ten of the athletes to compare sweat and plasma composition of amino acids. The amino acid profiles of the skin washings were similar to the sweat, suggesting that the NMF could contribute certain amino acids into sweat. Since the sweat collected from athletes contained some amino acid contributions from the skin, this fluid was subsequently referred to as “faux” sweat. Samples taken over 40 minutes of exercise showed that these contributions diminished over time and were minimal at 35 minutes. In the main study, the faux sweat samples collected from the athletes with minimal NMF contributions, were characterised by relatively high levels of serine, histidine, ornithine, glycine and alanine compared with the corresponding levels measured in the plasma. Aspartic acid was detected in faux sweat but not in the plasma. Glutamine and proline were lower in the faux sweat than plasma in all the athletes. Three phenotypic groups of athletes were defined based on faux sweat volumes and composition profiles of amino acids with varying relative abundances of histidine, serine, glycine and ornithine. It was concluded that for some individuals, faux sweat resulting from exercise at 32–34°C and 20–30% RH posed a potentially significant source of amino acid loss. PMID:27936120

  2. Skin Tattoos Alter Sweat Rate and Na+ Concentration.

    PubMed

    Luetkemeier, Maurie Joe; Hanisko, Joseph Michael; Aho, Kyle Mathiew

    2017-07-01

    The popularity of tattoos has increased tremendously in the last 10 yr particularly among athletes and military personnel. The tattooing process involves permanently depositing ink under the skin at a similar depth as eccrine sweat glands (3-5 mm). The purpose of this study was to compare the sweat rate and sweat Na concentration of tattooed versus nontattooed skin. The participants were 10 healthy men (age = 21 ± 1 yr), all with a unilateral tattoo covering a circular area at least 5.2 cm. Sweat was stimulated by iontophoresis using agar gel disks impregnated with 0.5% pilocarpine nitrate. The nontattooed skin was located contralateral to the position of the tattooed skin. The disks used to collect sweat were composed of Tygon® tubing wound into a spiral so that the sweat was pulled into the tubing by capillary action. The sweat rate was determined by weighing the disk before and after sweat collection. The sweat Na concentration was determined by flame photometry. The mean sweat rate from tattooed skin was significantly less than nontattooed skin (0.18 ± 0.15 vs 0.35 ± 0.25 mg·cm·min; P = 0.001). All 10 participants generated less sweat from tattooed skin than nontattooed skin and the effect size was -0.79. The mean sweat Na concentration from tattooed skin was significantly higher than nontattooed skin (69.1 ± 28.9 vs 42.6 ± 15.2 mmol·L; P = 0.02). Nine of 10 participants had higher sweat Na concentration from tattooed skin than nontattooed skin, and the effect size was 1.01. Tattooed skin generated less sweat and a higher Na concentration than nontattooed skin when stimulated by pilocarpine iontophoresis.

  3. Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis

    PubMed Central

    Nyein, Hnin Yin Yin; Challa, Samyuktha; Chen, Kevin; Peck, Austin; Fahad, Hossain M.; Ota, Hiroki; Shiraki, Hiroshi; Kiriya, Daisuke; Lien, Der-Hsien; Brooks, George A.; Davis, Ronald W.; Javey, Ali

    2016-01-01

    Wearable sensor technologies are essential to the realization of personalized medicine through continuously monitoring an individual's state of health1–12. Sampling human sweat, which is rich in physiological information13, could enable non-invasive monitoring. Previously reported sweat-based and other non-invasive biosensors either can only monitor a single analyte at a time or lack on-site signal processing circuitry and sensor calibration mechanisms for accurate analysis of the physiological state14–18. Given the complexity of sweat secretion, simultaneous and multiplexed screening of target biomarkers is critical and requires full system integration to ensure the accuracy of measurements. Here we present a mechanically flexible and fully integrated (that is, no external analysis is needed) sensor array for multiplexed in situ perspiration analysis, which simultaneously and selectively measures sweat metabolites (such as glucose and lactate) and electrolytes (such as sodium and potassium ions), as well as the skin temperature (to calibrate the response of the sensors). Our work bridges the technological gap between signal transduction, conditioning (amplification and filtering), processing and wireless transmission in wearable biosensors by merging plastic-based sensors that interface with the skin with silicon integrated circuits consolidated on a flexible circuit board for complex signal processing. This application could not have been realized using either of these technologies alone owing to their respective inherent limitations. The wearable system is used to measure the detailed sweat profile of human subjects engaged in prolonged indoor and outdoor physical activities, and to make a real-time assessment of the physiological state of the subjects. This platform enables a wide range of personalized diagnostic and physiological monitoring applications. PMID:26819044

  4. The effect of heat acclimation on sweat microminerals: Artifact of surface contamination

    USDA-ARS?s Scientific Manuscript database

    Heat acclimation (HA) reportedly conveys conservation in sweat micromineral concentrations when sampled from arm sweat, but time course is unknown. The observation that comprehensive cleaning of the skin surface negates sweat micromineral reductions during prolonged sweating raises the question of w...

  5. Integrated sudomotor axon reflex sweat stimulation for continuous sweat analyte analysis with individuals at rest.

    PubMed

    Sonner, Zachary; Wilder, Eliza; Gaillard, Trudy; Kasting, Gerald; Heikenfeld, Jason

    2017-07-25

    Eccrine sweat has rapidly emerged as a non-invasive, ergonomic, and rich source of chemical analytes with numerous technological demonstrations now showing the ability for continuous electrochemical sensing. However, beyond active perspirers (athletes, workers, etc.), continuous sweat access in individuals at rest has hindered the advancement of both sweat sensing science and technology. Reported here is integration of sudomotor axon reflex sweat stimulation for continuous wearable sweat analyte analysis, including the ability for side-by-side integration of chemical stimulants & sensors without cross-contamination. This integration approach is uniquely compatible with sensors which consume the analyte (enzymatic) or sensors which equilibrate with analyte concentrations. In vivo validation is performed using iontophoretic delivery of carbachol with ion-selective and impedance sensors for sweat analysis. Carbachol has shown prolonged sweat stimulation in directly stimulated regions for five hours or longer. This work represents a significant leap forward in sweat sensing technology, and may be of broader interest to those interested in on-skin sensing integrated with drug-delivery.

  6. Use of Biomarkers to Optimize Heat Acclimation in Women

    DTIC Science & Technology

    1996-10-01

    that synthesis of HSP72 was induced in lymphocytes, spleen cells and soleus muscle after 20 min of exercise while rectal temperature elevated above 40...lethal temperatures for death due to nonexertionally and exertionally induced heat exhaustion, respectively (15). Upon completion of the exercise ...During exercise , interstitial fluid levels are reduced due to sweat formation and fluid shifts which tend to induce hypovolemia, compromising

  7. Development of mathematical models of environmental physiology

    NASA Technical Reports Server (NTRS)

    Stolwijk, J. A. J.; Mitchell, J. W.; Nadel, E. R.

    1971-01-01

    Selected articles concerned with mathematical or simulation models of human thermoregulation are presented. The articles presented include: (1) development and use of simulation models in medicine, (2) model of cardio-vascular adjustments during exercise, (3) effective temperature scale based on simple model of human physiological regulatory response, (4) behavioral approach to thermoregulatory set point during exercise, and (5) importance of skin temperature in sweat regulation.

  8. Sweat patterns differ between tilt-induced reflex syncope and tilt-induced anxiety among youth.

    PubMed

    Heyer, Geoffrey L; Harvey, Rebecca A; Islam, Monica P

    2016-08-01

    Profound sweating can occur with reflex-syncope and with emotional distress, but little is known about the similarities and differences between these sweat responses when they occur during orthostatic challenge. We sought to characterize and compare the sweat patterns related to tilt-induced syncope, presyncope, anxiety, and normal tilt testing. In a prospective observational study, quantitative sweat rate was measured from the abdomen, forearm, ankle, and thigh during head-upright tilt. Sweat characteristics were compared across tilt diagnoses of syncope, presyncope, anxiety, and normal testing. When anxiety and syncope/presyncope occurred during the same study (separated by ≥6 min), both were diagnosed. Our cohort comprised150 patients (15.1 ± 2.3 years; 82.9 % female) with 156 diagnoses: 76 with reflex-syncope, 31 with presyncope, 23 with anxiety, and 26 with normal results. All syncope/presyncope patients and 20 (87 %) of the anxiety patients had corresponding sweat responses. Minimal or negligible sweating occurred among patients with normal tests. Neither basal sweat (19.4 ± 4.7 versus 18.3 ± 3.7 versus 18.5 ± 3.7 nL/min/cm(2)) nor peak sweat (171 ± 47.4 versus 149.4 ± 64.4 versus 154.4 ± 59.2 nL/min/cm(2)) differed between patients with syncope, presyncope, or anxiety, p = .32 and p = .12, respectively. However, the qualitative sweat patterns related to syncope/presyncope (diffuse, smoothly contoured, symmetrical, single peaks) differed considerably from the sweat patterns related to anxiety (heterogeneous, asymmetrical, roughly contoured single-peak, multi-peak, or progressive sweat changes). The sweat patterns related to syncope/presyncope are distinguishable from the sweat patterns related to anxiety. Recognition of the different sweat patterns can inform how signs and symptoms are interpreted during clinical orthostatic challenge.

  9. Combined facial heating and inhalation of hot air do not alter thermoeffector responses in humans.

    PubMed

    Wingo, Jonathan E; Low, David A; Keller, David M; Kimura, Kenichi; Crandall, Craig G

    2015-09-01

    The influence of thermoreceptors in human facial skin on thermoeffector responses is equivocal; furthermore, the presence of thermoreceptors in the respiratory tract and their involvement in thermal homeostasis has not been elucidated. This study tested the hypothesis that hot air directed on the face and inhaled during whole body passive heat stress elicits an earlier onset and greater sensitivity of cutaneous vasodilation and sweating than that directed on an equal skin surface area away from the face. Six men and two women completed two trials separated by ∼1 wk. Participants were passively heated (water-perfused suit; core temperature increase ∼0.9°C) while hot air was directed on either the face or on the lower leg (counterbalanced). Skin blood flux (laser-Doppler flowmetry) and local sweat rate (capacitance hygrometry) were measured at the chest and one forearm. During hot-air heating, local temperatures of the cheek and leg were 38.4 ± 0.8°C and 38.8 ± 0.6°C, respectively (P = 0.18). Breathing hot air combined with facial heating did not affect mean body temperature onsets (P = 0.97 and 0.27 for arm and chest sites, respectively) or slopes of cutaneous vasodilation (P = 0.49 and 0.43 for arm and chest sites, respectively), or the onsets (P = 0.89 and 0.94 for arm and chest sites, respectively), or slopes of sweating (P = 0.48 and 0.65 for arm and chest sites, respectively). Based on these findings, respiratory tract thermoreceptors, if present in humans, and selective facial skin heating do not modulate thermoeffector responses during passive heat stress. Copyright © 2015 the American Physiological Society.

  10. Comparison of workers' perceptions toward work climate and health symptoms between ceramic and iron foundry workers.

    PubMed

    Majumder, Joydeep; Bagepally, Bhavani S; Shah, Priyanka; Kotadiya, Sanjay; Yadav, Suresh; Naha, Nibedita

    2016-01-01

    Workers exposed to heavy manual material handling (MMH) in a hot working environment succumb to severe physical stress and psychological stress. (1) Recognize the heat load at workplaces of ceramic industry and iron industry, and (2) comparatively examine the characteristics of self-reported physiological responses and heat-health perception among these workers. Cross-sectional prospective study. Workplace microclimate in the ceramic industry and iron industry was monitored. An ergonomic checklist and a questionnaire was used to record self-reported workers' perceptions toward heat stress at workplace (ceramic workers N = 321, iron foundry workers N = 253). The prevalence rates of subjective symptoms among workers of both the industries were compared. Chi-square test was used to examine the association between stressors and health complaints at a significance level set at P < 0.05. Iron foundries recorded higher mean ambient temperature (43.4 ± 3.7°C) and wet-bulb globe temperature (WGBT) index (31.5 ± 0.7°C) as compared to ceramic industries (39.9 ± 3.3°C and 28 ± 1.5°C, respectively). Heavy sweating, elevated body temperature, sleeplessness, excessive thirst, muscular discomforts, and fatigue were prime symptoms recorded among workers of both industries. Skin-related disorders (red face, dry skin, bumps, itching) were significantly higher among iron foundry workers, whereas sleeplessness, high blood pressure, heavy sweating, kidney stone, decreased urination, muscular discomforts, and fatigue were significantly more among ceramic workers. Young workers reported more sweating and fatigue than older workers. A hot work climate and heavy manual labor designate ceramic and iron industries as arduous. Direct contact with hot surface and continuous MMH in tandem with the mechanical pace of production process makes work in ceramic industries more difficult than iron foundries.

  11. Iron losses in sweat

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brune, M.; Magnusson, B.; Persson, H.

    The losses of iron in whole body cell-free sweat were determined in eleven healthy men. A new experimental design was used with a very careful cleaning procedure of the skin and repeated consecutive sampling periods of sweat in a sauna. The purpose was to achieve a steady state of sweat iron losses with minimal influence from iron originating from desquamated cells and iron contaminating the skin. A steady state was reached in the third sauna period (second sweat sampling period). Iron loss was directly related to the volume of sweat lost and amounted to 22.5 micrograms iron/l sweat. The findingsmore » indicate that iron is a physiological constituent of sweat and derived not only from contamination. Present results imply that variations in the amount of sweat lost will have only a marginal effect on the variation in total body iron losses.« less

  12. Regional relation between skin blood flow and sweating to passive heating and local administration of acetylcholine in young, healthy humans.

    PubMed

    Smith, Caroline J; Kenney, W Larry; Alexander, Lacy M

    2013-04-01

    Regional variation in sweating over the human body is widely recognized yet variation in vasomotor responses and mechanisms causing this variation remain unclear. This study aimed to explore the relation between regional sweating rates (RSR) and skin blood flow (SkBF) responses to thermal and pharmacological stimuli in young, healthy subjects. In nine subjects (23 ± 3 yr), intradermal microdialysis (MD) probes were inserted into the ventral forearm, abdomen, thigh, and lower back and perfused with lactated Ringer solution. RSR over each MD membrane were measured using ventilated capsules with a laser Doppler probe housed in each capsule for measurement of red cell flux (laser Doppler flux, LDF) as an index of SkBF. Subjects completed a whole body heating protocol to 1°C rise in oral temperature and an acetylcholine dose response (ACh 1 × 10(-7)-0.1 M; mean skin temperature 34°C). Maximal LDF were obtained at the end of both protocols (50 mM sodium nitroprusside).During heating RSR varied among sites (P < 0.0001) and was greater on the back versus other sites (P < 0.05), but LDF was similar between sites (P = 0.343). RSR and SkBF showed a strong relation during initial (arm: r = 0.77 ± 0.09, thigh: r = 0.81 ± 0.08, abdomen: r = 0.89 ± 0.04, back: r = 0.86 ± 0.04) but not latter stages of heating. No differences in RSR (P = 0.160) or SkBF (LDF, P = 0.841) were observed between sites during ACh perfusion. Taken together, these data suggest that increases in SkBF are necessary to initiate and increase sweating, but further rises in RSR are not fully dependent on SkBF in a dose-response manner. Furthermore, RSR cannot be explained by cholinergic sensitivity or variation in SkBF.

  13. Thermoregulation, Fluid Balance, and Sweat Losses in American Football Players.

    PubMed

    Davis, Jon K; Baker, Lindsay B; Barnes, Kelly; Ungaro, Corey; Stofan, John

    2016-10-01

    Numerous studies have reported on the thermoregulation and hydration challenges athletes face in team and individual sports during exercise in the heat. Comparatively less research, however, has been conducted on the American Football player. Therefore, the purpose of this article is to review data collected in laboratory and field studies and discuss the thermoregulation, fluid balance, and sweat losses of American Football players. American Football presents a unique challenge to thermoregulation compared with other sports because of the encapsulating nature of the required protective equipment, large body size of players, and preseason practice occurring during the hottest time of year. Epidemiological studies report disproportionately higher rates of exertional heat illness and heat stroke in American Football compared with other sports. Specifically, larger players (e.g., linemen) are at increased risk for heat ailments compared with smaller players (e.g., backs) because of greater body mass index, increased body fat, lower surface area to body mass ratio, lower aerobic capacity, and the stationary nature of the position, which can reduce heat dissipation. A consistent finding across studies is that larger players exhibit higher sweating rates than smaller players. Mean sweating rates from 1.0 to 2.9 L/h have been reported for college and professional American Football players, with several studies reporting 3.0 L/h or more in some larger players. Sweat sodium concentration of American Football players does not seem to differ from that of athletes in other sports; however, given the high volume of sweat loss, the potential for sodium loss is higher in American Football than in other sports. Despite high sweating rates with American Football players, the observed disturbances in fluid balance have generally been mild (mean body mass loss ≤2 %). The majority of field-based studies have been conducted in the northeastern part of the United States, with limited studies in different geographical regions (i.e., southeast) of the United States. Further, there have been a limited number of studies examining body core temperature of American Football players during preseason practice, especially at the high school level. Future field-based research in American Football with various levels of competition in hotter geographical regions of the United States is warranted.

  14. Urea transporters and sweat response to uremia.

    PubMed

    Keller, Raymond W; Bailey, James L; Wang, Yanhua; Klein, Janet D; Sands, Jeff M

    2016-06-01

    In humans, urea is excreted in sweat, largely through the eccrine sweat gland. The urea concentration in human sweat is elevated when compared to blood urea nitrogen. The sweat urea nitrogen (UN) of patients with end-stage kidney disease (ESRD) is increased when compared with healthy humans. The ability to produce sweat is maintained in the overwhelming majority of ESRD patients. A comprehensive literature review found no reports of sweat UN neither in healthy rodents nor in rodent models of chronic kidney disease (CKD). Therefore, this study measured sweat UN concentrations in healthy and uremic rats. Uninephrectomy followed by renal artery ligation was used to remove 5/6 of renal function. Rats were then fed a high-protein diet to induce uremia. Pilocarpine was used to induce sweating. Sweat droplets were collected under oil. Sweat UN was measured with a urease assay. Serum UN was measured using a fluorescent ortho-pthalaldehyde reaction. Immunohistochemistry (IHC) was accomplished with a horseradish peroxidase and diaminobenzidine technique. Sweat UN in uremic rats was elevated greater than two times compared to healthy pair-fed controls (220 ± 17 and 91 ± 15 mmol/L, respectively). Post hoc analysis showed a significant difference between male and female uremic sweat UN (279 ± 38 and 177 ± 11 mmol/L, respectively.) IHC shows, for the first time, the presence of the urea transporters UT-B and UT-A2 in both healthy and uremic rat cutaneous structures. Future studies will use this model to elucidate how rat sweat UN and other solute excretion is altered by commonly prescribed diuretics. © 2016 The Authors. Physiological Reports published by Wiley Periodicals, Inc. on behalf of the American Physiological Society and The Physiological Society.

  15. Heat Waves

    MedlinePlus

    ... This typically occurs when people exercise heavily or work in a hot, humid place where body fluids are lost through heavy sweating. Blood flow to the skin increases, causing blood flow to decrease to the vital organs. This ... cool the body, stops working. The body temperature can rise so high that ...

  16. Testing in artificial sweat - Is less more? Comparison of metal release in two different artificial sweat solutions.

    PubMed

    Midander, Klara; Julander, Anneli; Kettelarij, Jolinde; Lidén, Carola

    2016-11-01

    Metal release from materials immersed in artificial sweat can function as a measure of potential skin exposure. Several artificial sweat models exist that, to various degree, mimic realistic conditions. Study objective was to evaluate metal release from previously examined and well characterized materials in two different artificial sweat solutions; a comprehensive sweat model intended for use within research, based on the composition of human sweat; and the artificial sweat, EN1811, intended for testing compliance with the nickel restriction in REACH. The aim was to better understand whether there are advantages using either of the sweat solutions in bio-elution testing of materials. Metal release in two different artificial sweat solutions was compared for discs of a white gold alloy and two hard metals, and a rock drilling insert of tungsten carbide at 1 h, 24 h, 1 week and 1 month. The released amount of metal was analysed by means of inductively coupled plasma mass spectrometry. Similar levels of released metals were measured from test materials in the two different artificial sweat solutions. For purposes in relation to legislations, it was concluded that a metal release test using a simple artificial sweat composition may provide results that sufficiently indicate the degree of metal release at skin contact. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. Thermophysiological responses induced by a body heat removal system with Peltier devices in a hot environment.

    PubMed

    Suzurikawa, Jun; Fujimoto, Sho; Mikami, Kousei; Jonai, Hiroshi; Inoue, Takenobu

    2013-01-01

    Individuals with spinal cord injuries often experience thermoregulation disorders as well as sensory and motor disabilities. In order to prevent such individuals from becoming hyperthermic, we developed a body heat removal system (BHRS) with thermoelectric devices. Our BHRS comprises four Peltier devices mounted on a wheelchair backrest and continuously transfers body heat through the contacting interface to the external environment. Here, we characterized thermophysiological responses induced by this novel contact-type cooling system. A cooling experiment in a hot environment with five able-bodied subjects demonstrated that sweating and systolic blood pressure in the back-cooling (BC) trial were significantly suppressed compared with those in no-cooling (NC) trial, while no difference was found in oral and skin temperatures. A correlation was observed between chest skin temperature and blood flow in the NC trial; this was not observed in the BC trial. These results suggest that BHRS modulates normal thermoregulatory responses, including sweating and vascular dilation and has the capability to partly replace these functions.

  18. Effect of stride frequency on thermoregulatory responses during endurance running in distance runners.

    PubMed

    Amano, Tatsuro; Ishitobi, Masaki; Ogura, Yukio; Inoue, Yoshimitsu; Koga, Shunsaku; Nishiyasu, Takeshi; Kondo, Narihiko

    2016-10-01

    Changing stride frequency may influence oxygen uptake and heart rate during running as a function of running economy and central command. This study investigated the influence of stride frequency manipulation on thermoregulatory responses during endurance running. Seven healthy endurance runners ran on a treadmill at a velocity of 15km/h for 60min in a controlled environmental chamber (ambient temperature 27°C and relative humidity 50%), and stride frequency was manipulated. Stride frequency was intermittently manipulated by increasing and decreasing frequency by 10% from the pre-determined preferred frequency. These periods of increase or decrease were separated by free frequency running in the order of free stride frequency, stride frequency manipulation (increase or decrease), free stride frequency, and stride frequency manipulation (increase or decrease) for 15min each. The increased and decreased stride frequencies were 110% and 91% of the free running frequency, respectively (196±6, 162±5, and 178±5steps/min, respectively, P<0.01). Compared to the control, stride frequency manipulation did not affect rectal temperature, heart rate, or the rate of perceived exhaustion during running. Whole-body sweat loss increased significantly when stride frequency was manipulated (1.48±0.11 and 1.57±0.11kg for control and manipulated stride frequencies, respectively, P<0.05), but stride frequency had a small effect on sweat loss overall (Cohen's d=0.31). A higher mean skin temperature was also observed under mixed frequency conditions compared to that in the control (P<0.05). While the precise mechanisms underlying these changes remain unknown (e.g. running economy or central command), our results suggest that manipulation of stride frequency does not have a large effect on sweat loss or other physiological variables, but does increase mean skin temperature during endurance running. Copyright © 2016. Published by Elsevier Ltd.

  19. Individualizing osteoporosis medications.

    PubMed

    Silverman, Stuart

    2014-03-01

    Mrs. JD is a 58-year-old postmenopausal woman having symptoms of hot flashes and night sweats. She has a dual-energy x-ray absorptiometry T-score of -2.4 in the femoral neck, consistent with low bone mass or osteopenia. She has a parental history of hip fracture. FRAX shows the 10-year absolute risk of major osteoporotic fracture equal to 18% and the 10-year risk of hip fracture above 3% at 3.2%, which meets the National Osteoporosis Foundation threshold. Mrs. JD is taking calcium 1,200 mg, between supplement and diet, and 1,000 IU vitamin D3 daily. How should she be treated?

  20. Biochemical changes in sweat following prolonged ischemia.

    PubMed

    Ferguson-Pell, M; Hagisawa, S

    1988-01-01

    Much emphasis has been placed on the measurement of physical parameters at the body support interface in order to detect and moderate conditions which could result in pressure damage to soft tissues. Major difficulties are encountered both in the design of instrumentation and interpretation of the data collected. Metabolic processes in sweat glands that control sweat secretion have been shown to be sensitive to applied pressure, producing sweating rate suppression and changes in sweat NaCl concentration. In this study, we have demonstrated the feasibility of measuring lactate concentration in sweat collected locally using an electrochemical stimulation technique (iontophoresis of pilocarpine nitrate). Elevated levels of sweat lactate concentration during local tissue indentation were detected in a group of able-bodied subjects. Upon removal of the indentor, however, levels of sweat lactate returned to normal.

  1. Proteomic and peptidomic analysis of human sweat with emphasis on proteolysis.

    PubMed

    Yu, Yijing; Prassas, Ioannis; Muytjens, Carla M J; Diamandis, Eleftherios P

    2017-02-23

    Sweat is produced by eccrine and apocrine glands and represents a biological fluid with established roles in thermo-regulation and host infection defense. The composition of sweat is highly dynamic and alters significantly in various skin and other disorders. Therefore, in-depth profiling of sweat protein composition is expected to augment our understanding of the pathobiology of several skin diseases and may lead to the identification of useful sweat-based disease biomarkers. We here reported an in-depth analysis of the human sweat proteome and peptidome. Sweat was collected from healthy males and healthy females of ages 20-60years, following strenuous exercise. Two sweat pools were prepared (1 for males and 1 for females) and were subjected to sample preparation for mass spectrometric analysis. We identified a total of 861 unique proteins during our proteomic analysis and 32,818 endogenous peptides (corresponding to additional 1067 proteins) from our peptidomics workflow. As expected, the human skin was identified as the most abundant source of sweat proteins and peptides. Several skin proteases and protease inhibitors were identified in human sweat, highlighting the intense proteolytic activity of human skin. The presence of several antimicrobial peptides supports the functional roles of sweat in host defense and innate immunity. Sweat is a skin-associated biological fluid, secreted by eccrine and apocrine glands, with essential function in body thermo-regulation and host infection defense. In the present study, we performed in-depth profiling of both sweat proteome and peptidome composition. Our data provide the most in-depth characterization of the skin's catalytic network present in sweat. For the first time, we brought to light novel peptides in human sweat that potentially have antimicrobial activity, which highlight the important role of this fluid in innate immunity. All these findings allow us to have a better understanding of the complex web of proteases in skin and may act as a platform for the future discovery of novel skin biomarkers. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. A novel organotypic 3D sweat gland model with physiological functionality

    PubMed Central

    Grüdl, Sabine; Banowski, Bernhard; Giesen, Melanie; Sättler, Andrea; Proksch, Peter; Welss, Thomas; Förster, Thomas

    2017-01-01

    Dysregulated human eccrine sweat glands can negatively impact the quality-of-life of people suffering from disorders like hyperhidrosis. Inability of sweating can even result in serious health effects in humans affected by anhidrosis. The underlying mechanisms must be elucidated and a reliable in vitro test system for drug screening must be developed. Here we describe a novel organotypic three-dimensional (3D) sweat gland model made of primary human eccrine sweat gland cells. Initial experiments revealed that eccrine sweat gland cells in a two-dimensional (2D) culture lose typical physiological markers. To resemble the in vivo situation as close as possible, we applied the hanging drop cultivation technology regaining most of the markers when cultured in its natural spherical environment. To compare the organotypic 3D sweat gland model versus human sweat glands in vivo, we compared markers relevant for the eccrine sweat gland using transcriptomic and proteomic analysis. Comparing the marker profile, a high in vitro-in vivo correlation was shown. Carcinoembryonic antigen-related cell adhesion molecule 5 (CEACAM5), muscarinic acetylcholine receptor M3 (CHRM3), Na+-K+-Cl- cotransporter 1 (NKCC1), calcium-activated chloride channel anoctamin-1 (ANO1/TMEM16A), and aquaporin-5 (AQP5) are found at significant expression levels in the 3D model. Moreover, cholinergic stimulation with acetylcholine or pilocarpine leads to calcium influx monitored in a calcium flux assay. Cholinergic stimulation cannot be achieved with the sweat gland cell line NCL-SG3 used as a sweat gland model system. Our results show clear benefits of the organotypic 3D sweat gland model versus 2D cultures in terms of the expression of essential eccrine sweat gland key regulators and in the physiological response to stimulation. Taken together, this novel organotypic 3D sweat gland model shows a good in vitro-in vivo correlation and is an appropriate alternative for screening of potential bioactives regulating the sweat mechanism. PMID:28796813

  3. Sweating - absent

    MedlinePlus

    ... page, please enable JavaScript. An abnormal lack of sweat in response to heat may be harmful, because ... diseases or scarring of the skin that block sweat glands Trauma to sweat glands Use of certain ...

  4. Effects of cooling portions of the head on human thermoregulatory response.

    PubMed

    Katsuura, T; Tomioka, K; Harada, H; Iwanaga, K; Kikuchi, Y

    1996-03-01

    Seven healthy young male students participated in this study. Each subject sat on a chair in an anteroom at 25 degrees C for 30 min and then entered a climatic chamber, controlled at 40 degrees C and R.H. 50%, and sat on a chair for 90 min. Cooling of frontal portion including the region around the eyes (FC), occipital portion (OC), and temporal portion (TC) began after 50 min of entering. An experiment without head cooling (NC) was also made for the control measurement. Thermal comfort and thermal sensation were improved by head cooling, but response was the same regardless of portion cooled. Although rectal temperature, mean skin temperature and heart rate showed no significant effect due to head cooling, forearm skin blood flow (FBF), sweat rate (SR), and body weight loss (delta Wt) had a tendency to be depressed. FBF in FC and TC decreased during head cooling, but that in OC and NC did not change significantly, while SR in FC was depressed. delta Wt showed total sweating to decrease by FC and TC, and FC to have greater inhibitory effect on sweating than OC. Thermal strain was evaluated by the modified Craig Index (I(s)). I(s) in FC decreased significantly more than in NC. Cooling of other portions of the head had no significant effect on I(s). Cooling of the frontal portion of the head may thus be concluded to have the most effect on thermoregulatory response in a hot environment.

  5. Sweat test for cystic fibrosis: Wearable sweat sensor vs. standard laboratory test.

    PubMed

    Choi, Dong-Hoon; Thaxton, Abigail; Jeong, In Cheol; Kim, Kain; Sosnay, Patrick R; Cutting, Garry R; Searson, Peter C

    2018-03-23

    Sweat chloride testing for diagnosis of cystic fibrosis (CF) involves sweat induction, collection and handling, and measurement in an analytical lab. We have developed a wearable sensor with an integrated salt bridge for real-time measurement of sweat chloride concentration. Here, in a proof-of-concept study, we compare the performance of the sensor to current clinical practice in CF patients and healthy subjects. Sweat was induced on both forearms of 10 individuals with CF and 10 healthy subjects using pilocarpine iontophoresis. A Macroduct sweat collection device was attached to one arm and sweat was collected for 30 min and then sent for laboratory analysis. A sensor was attached to the other arm and the chloride ion concentration monitored in real time for 30 min using a Bluetooth transceiver and smart phone app. Stable sweat chloride measurements were obtained within 15 min following sweat induction using the wearable sensor. We define the detection time as the time at which the standard deviation of the real-time chloride ion concentration remained below 2 mEq/L for 5 min. The sweat volume for sensor measurements at the detection time was 13.1 ± 11.4 μL (SD), in many cases lower than the minimum sweat volume of 15 μL for conventional testing. The mean difference between sweat chloride concentrations measured by the sensor and the conventional laboratory practice was 6.2 ± 9.5 mEq/L (SD), close to the arm-to-arm variation of about 3 mEq/L. The Pearson correlation coefficient between the two measurements was 0.97 highlighting the excellent agreement between the two methods. A wearable sensor can be used to make real-time measurements of sweat chloride within 15 min following sweat induction, requiring a small sweat volume, and with excellent agreement to standard methods. Copyright © 2018 European Cystic Fibrosis Society. Published by Elsevier B.V. All rights reserved.

  6. Effect of low air velocities on thermal homeostasis and comfort during exercise at space station operational temperature and humidity

    NASA Technical Reports Server (NTRS)

    Beumer, Ronald J.

    1989-01-01

    The effectiveness of different low air velocities in maintaining thermal comfort and homeostasis during exercise at space station operational temperature and humidity was investigated. Five male subjects exercised on a treadmill for successive ten minute periods at 60, 71, and 83 percent of maximum oxygen consumption at each of four air velocities, 30, 50, 80, and 120 ft/min, at 22 C and 62 percent relative humidity. No consistent trends or statistically significant differences between air velocities were found in body weight loss, sweat accumulation, or changes in rectal, skin, and body temperatures. Occurrence of the smallest body weight loss at 120 ft/min, the largest sweat accumulation at 30 ft/min, and the smallest rise in rectal temperature and the greatest drop in skin temperature at 120 ft/min all suggested more efficient evaporative cooling at the highest velocity. Heat storage at all velocities was evidenced by increased rectal and body temperatures; skin temperatures declined or increased only slightly. Body and rectal temperature increases corresponded with increased perception of warmth and slight thermal discomfort as exercise progressed. At all air velocities, mean thermal perception never exceeded warm and mean discomfort, greatest at 30 ft/min, was categorized at worst as uncomfortable; sensation of thermal neutrality and comfort returned rapidly after cessation of exercise. Suggestions for further elucidation of the effects of low air velocities on thermal comfort and homeostasis include larger numbers of subjects, more extensive skin temperature measurements and more rigorous analysis of the data from this study.

  7. Investigating the Effects of Sweat Therapy on Group Dynamics and Affect

    ERIC Educational Resources Information Center

    Colmant, Stephen A.; Eason, Evan A.; Winterowd, Carrie L.; Jacobs, Sue C.; Cashel, Chris

    2005-01-01

    In this study, we examined the effects of sweat therapy on group dynamics and affect. Sweat therapy is the combination of intense heat exposure with psychotherapy or counseling (Colmant & Merta, 1999; 2000). Twenty-four undergraduates were separated by sex and randomly assigned to eight sessions of either a sweat or non-sweat group counseling…

  8. Correction of the heat loss method for calculating clothing real evaporative resistance.

    PubMed

    Wang, Faming; Zhang, Chengjiao; Lu, Yehu

    2015-08-01

    In the so-called isothermal condition (i.e., Tair [air temperature]=Tmanikin [manikin temperature]=Tr [radiant temperature]), the actual energy used for moisture evaporation detected by most sweating manikins was underestimated due to the uncontrolled fabric 'skin' temperature Tsk,f (i.e., Tsk,f

  9. Rain influences the physiological and metabolic responses to exercise in hot conditions.

    PubMed

    Ito, Ryo; Yamashita, Naoyuki; Suzuki, Eiko; Matsumoto, Takaaki

    2015-01-01

    Outdoor exercise often proceeds in rainy conditions. However, the cooling effects of rain on human physiological responses have not been systematically studied in hot conditions. The present study determined physiological and metabolic responses using a climatic chamber that can precisely simulate hot, rainy conditions. Eleven healthy men ran on a treadmill at an intensity of 70% VO2max for 30 min in the climatic chamber at an ambient temperature of 33°C in the presence (RAIN) or absence (CON) of 30 mm · h(-1) of precipitation and a headwind equal to the running velocity of 3.15 ± 0.19 m · s(-1). Oesophageal temperature, mean skin temperature, heart rate, rating of perceived exertion, blood parameters, volume of expired air and sweat loss were measured. Oesophageal and mean skin temperatures were significantly lower from 5 to 30 min, and heart rate was significantly lower from 20 to 30 min in RAIN than in CON (P < 0.05 for all). Plasma lactate and epinephrine concentrations (30 min) and sweat loss were significantly lower (P < 0.05) in RAIN compared with CON. Rain appears to influence physiological and metabolic responses to exercise in heat such that heat-induced strain might be reduced.

  10. Hyperhidrosis (Excessive Sweating)

    MedlinePlus

    ... your daily routine Sweating causes emotional distress or social withdrawal You suddenly begin to sweat more than usual ... can lead to heavy sweating, as can opioid ... infections. Social and emotional effects. Having clammy or dripping hands ...

  11. Relationship between sweat chloride, sodium, and age in clinically obtained samples.

    PubMed

    Traeger, Nadav; Shi, Qiuhu; Dozor, Allen J

    2014-01-01

    The relationship between sweat electrolytes and age is uncertain, as is the value of measuring sodium or the chloride:sodium ratio. 13,785 sweat tests performed over 23 years at one center through the Macroduct collection in clinically obtained samples were analyzed. Sweat chloride tended to decrease over the first year of life, slowly increase until the fourth decade, then either level off or slightly decrease. In children, sweat sodium overlapped between those with positive and negative sweat tests, but not in adults. If the sweat test was positive, there was a higher likelihood of having a chloride:sodium ratio >1, but most subjects with a ratio >1 did not have CF. Sweat chloride and sodium vary with age. Measurement of sweat sodium did not add discriminatory value. The proportion of subjects with a chloride:sodium ratio >1, with or without CF, varied greatly between age ranges. © 2013. Published by Elsevier B.V. on behalf of European Cystic Fibrosis Society. All rights reserved.

  12. Sweat Chloride as A Biomarker of CFTR Activity: Proof of Concept and Ivacaftor Clinical Trial Data

    PubMed Central

    Accurso, Frank J.; Van Goor, Fredrick; Zha, Jiuhong; Stone, Anne J.; Dong, Qunming; Ordonez, Claudia L.; Rowe, Steven M.; Clancy, John Paul; Konstan, Michael W.; Hoch, Heather E.; Heltshe, Sonya L.; Ramsey, Bonnie W.; Campbell, Preston W.; Ashlock, Melissa A.

    2014-01-01

    Background We examined data from a Phase 2 trial {NCT00457821 } of ivacaftor, a CFTR potentiator, in cystic fibrosis (CF) patients with a G551D mutation to evaluate standardized approaches to sweat chloride measurement and to explore the use of sweat chloride and nasal potential difference (NPD) to estimate CFTR activity. Methods Sweat chloride and NPD were secondary endpoints in this placebo-controlled, multicenter trial. Standardization of sweat collection, processing, and analysis was employed for the first time.. Sweat chloride and chloride ion transport (NPD) were integrated into a model of CFTR activity. Results Within-patient sweat chloride determinations showed sufficient precision to detect differences between dose-groups and assess ivacaftor treatment effects. Analysis of changes in sweat chloride and NPD demonstrated that patients treated with ivacaftor achieved CFTR activity equivalent to approximately 35%–40% of normal. Conclusions Sweat chloride is useful in multicenter trials as a biomarker of CFTR activity and to test the effect of CFTR potentiators. PMID:24660233

  13. Sweat chloride as a biomarker of CFTR activity: proof of concept and ivacaftor clinical trial data.

    PubMed

    Accurso, Frank J; Van Goor, Fredrick; Zha, Jiuhong; Stone, Anne J; Dong, Qunming; Ordonez, Claudia L; Rowe, Steven M; Clancy, John Paul; Konstan, Michael W; Hoch, Heather E; Heltshe, Sonya L; Ramsey, Bonnie W; Campbell, Preston W; Ashlock, Melissa A

    2014-03-01

    We examined data from a Phase 2 trial {NCT00457821} of ivacaftor, a CFTR potentiator, in cystic fibrosis (CF) patients with aG551D mutation to evaluate standardized approaches to sweat chloride measurement and to explore the use of sweat chloride and nasal potential difference (NPD) to estimate CFTR activity. Sweat chloride and NPD were secondary endpoints in this placebo-controlled, multicenter trial. Standardization of sweat collection, processing,and analysis was employed for the first time. Sweat chloride and chloride ion transport (NPD) were integrated into a model of CFTR activity. Within-patient sweat chloride determinations showed sufficient precision to detect differences between dose-groups and assess ivacaftor treatment effects. Analysis of changes in sweat chloride and NPD demonstrated that patients treated with ivacaftor achieved CFTR activity equivalent to approximately 35%–40% of normal. Sweat chloride is useful in multicenter trials as a biomarker of CFTR activity and to test the effect of CFTR potentiators.

  14. Night Sweats

    MedlinePlus

    Symptoms Night sweats By Mayo Clinic Staff Night sweats are repeated episodes of extreme perspiration that may soak your nightclothes or ... these episodes are usually not labeled as night sweats and typically aren't a sign of a ...

  15. Genetics Home Reference: cold-induced sweating syndrome

    MedlinePlus

    ... Health Conditions Cold-induced sweating syndrome Cold-induced sweating syndrome Printable PDF Open All Close All Enable ... view the expand/collapse boxes. Description Cold-induced sweating syndrome is characterized by problems with regulating body ...

  16. Immediate Wheal Reactivity to Autologous Sweat in Atopic Dermatitis Is Associated with Clinical Severity, Serum Total and Specific IgE and Sweat Tryptase Activity.

    PubMed

    Ilves, Tiina; Virolainen, Anu; Harvima, Ilkka Tapani

    2016-01-01

    Sweating can worsen atopic dermatitis (AD). The purpose of this work was to study the associations between reactivity to autologous sweat and the clinical severity of AD as well as investigate the possible wheal-inducing factors of sweat. Intracutaneous skin tests with autologous sweat were performed on 50 AD patients and 24 control subjects. In skin biopsies, tryptase and PAR-2 were enzyme and immunohistochemically stained. The associations between skin test reactivity and sweat histamine concentration, tryptase or chymase activity levels, tryptase or PAR-2 expression and AD clinical severity or IgE levels were investigated. The wheal reactions in the intracutaneous tests with autologous sweat were positive, weakly positive and negative in 38, 34 and 28% of the AD patients, respectively, and in 4, 46 and 50% of the healthy controls, respectively (p = 0.008). In AD, the wheal reaction was associated significantly with clinical severity, serum total and specific IgE levels and sweat tryptase activity, but not with sweat histamine and chymase. In nonlesional AD skin, the percentage of PAR-2+ mast cells (MCs) or the number of tryptase+ MCs did not differ significantly between the intracutaneous test reactivity groups. Reactivity to autologous sweat correlates with the clinical severity of AD, and tryptase may be one of the factors involved in the sweat-induced wheal. © 2016 S. Karger AG, Basel.

  17. Hands-On Science: Cool Ways to Teach about Warm-Blooded Animals.

    ERIC Educational Resources Information Center

    VanCleave, Janice

    1998-01-01

    Presents three activities for teaching elementary students about the built-in mechanisms that help warm-blooded animals maintain constant internal body temperatures. The activities help students understand why humans sweat, why dogs pant, and why blubber keeps whales warm in frigid water. (SM)

  18. The effect of starting or stopping skin cooling on the thermoregulatory responses during leg exercise in humans.

    PubMed

    Demachi, K; Yoshida, T; Kume, M; Tsuneoka, H

    2012-07-01

    To assess the effects of starting or stopping leg cooling on the thermoregulatory responses during exercise, 60 min of cycling exercise at 30% of maximal oxygen uptake was performed under 4 conditions using tube trouser perfused with water at 10 °C; no leg cooling (NC), starting of leg cooling after 30 min of exercise (delayed cooling, DC), continuous leg cooling (CC), and stopping of continuous leg cooling after 30 min of exercise (SC) at an environmental temperature of 28.5 °C. During exercise under the DC conditions, an instantaneous increase in the esophageal temperature (Tes), a suppression of the cutaneous vascular conductance at the forearm (%CVC), and a decrease in the mean skin temperature (Tsk) were observed after leg cooling. The total sweat loss (Δm sw,tot) was lower under the DC than the NC condition. In the SC study, however, the Tes remained constant, while the %CVC increased gradually after leg cooling was stopped, and the Δm sw,tot was greater than that under the CC condition. These results suggest that during exercise, rapid skin cooling of the leg may cause an increase in core temperature, while also enhancing thermal stress. However, stopping skin cooling did not significantly affect the core temperature long-term, because the skin blood flow and sweat rate subsequently increased. © Georg Thieme Verlag KG Stuttgart · New York.

  19. Body map of regional vs. whole body sweating rate and sweat electrolyte concentrations in men and women during moderate exercise-heat stress.

    PubMed

    Baker, Lindsay B; Ungaro, Corey T; Sopeña, Bridget C; Nuccio, Ryan P; Reimel, Adam J; Carter, James M; Stofan, John R; Barnes, Kelly A

    2018-05-01

    This study determined the relations between regional (REG) and whole body (WB) sweating rate (RSR and WBSR, respectively) as well as REG and WB sweat Na + concentration ([Na + ]) during exercise. Twenty-six recreational athletes (17 men, 9 women) cycled for 90 min while WB sweat [Na + ] was measured using the washdown technique. RSR and REG sweat [Na + ] were measured from nine regions using absorbent patches. RSR and REG sweat [Na + ] from all regions were significantly ( P < 0.05) correlated with WBSR ( r = 0.58-0.83) and WB sweat [Na + ] ( r = 0.74-0.88), respectively. However, the slope and y-intercept of the regression lines for most models were significantly different than 1 and 0, respectively. The coefficients of determination ( r 2 ) were 0.44-0.69 for RSR predicting WBSR [best predictors: dorsal forearm ( r 2  = 0.62) and triceps ( r 2  = 0.69)] and 0.55-0.77 for REG predicting WB sweat [Na + ] [best predictors: ventral forearm ( r 2  = 0.73) and thigh ( r 2  = 0.77)]. There was a significant ( P < 0.05) effect of day-to-day variability on the regression model predicting WBSR from RSR at most regions but no effect on predictions of WB sweat [Na + ] from REG. Results suggest that REG cannot be used as a direct surrogate for WB sweating responses. Nonetheless, the use of regression equations to predict WB sweat [Na + ] from REG can provide an estimation of WB sweat [Na + ] with an acceptable level of accuracy, especially using the forearm or thigh. However, the best practice for measuring WBSR remains conventional WB mass balance calculations since prediction of WBSR from RSR using absorbent patches does not meet the accuracy or reliability required to inform fluid intake recommendations. NEW & NOTEWORTHY This study developed a body map of regional sweating rate and regional (REG) sweat electrolyte concentrations and determined the effect of within-subject (bilateral and day-to-day) and between-subject (sex) factors on the relations between REG and the whole body (WB). Regression equations can be used to predict WB sweat Na + concentration from REG, especially using the forearm or thigh. However, prediction of WB sweating rate from REG sweating rate using absorbent patches does not reach the accuracy or reliability required to inform fluid intake recommendations.

  20. In vivo sweat film layer thickness measured with Fourier-domain optical coherence tomography (FD-OCT)

    NASA Astrophysics Data System (ADS)

    Jonathan, Enock

    2008-06-01

    While human sweat secretion is accepted as a mechanism by which the body cools off, excessive sweating (hyperhidrosis) is now appreciated as a medical condition and the primary site for diagnosis is the palm of the hand. We propose sweat film layer thickness as a potential clinical diagnostic parameter when screening for excessive sweating. In this preliminary study we demonstrate the usefulness of Fourier-domain optical coherence tomography (FD-OCT) for measurement of sweat film thickness in vivo with micron-scale resolution on the hand of a human volunteer. FD-OCT has a superior image acquisition time and identification of active sweat glands, ducts and pores is also possible.

  1. 21 CFR 350.50 - Labeling of antiperspirant drug products.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... following: “dampness,” “perspiration,” “sweat,” “sweating,” or “wetness”]. (2) The labeling may state “also...: ‘dampness,’ ‘perspiration,’ ‘sweat,’ ‘sweating,’ or ‘wetness’] due to stress”. (3) For products that demonstrate standard effectiveness (20 percent sweat reduction) over a 24-hour period, the labeling may state...

  2. 21 CFR 350.50 - Labeling of antiperspirant drug products.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... following: “dampness,” “perspiration,” “sweat,” “sweating,” or “wetness”]. (2) The labeling may state “also...: ‘dampness,’ ‘perspiration,’ ‘sweat,’ ‘sweating,’ or ‘wetness’] due to stress”. (3) For products that demonstrate standard effectiveness (20 percent sweat reduction) over a 24-hour period, the labeling may state...

  3. 21 CFR 350.50 - Labeling of antiperspirant drug products.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... following: “dampness,” “perspiration,” “sweat,” “sweating,” or “wetness”]. (2) The labeling may state “also...: ‘dampness,’ ‘perspiration,’ ‘sweat,’ ‘sweating,’ or ‘wetness’] due to stress”. (3) For products that demonstrate standard effectiveness (20 percent sweat reduction) over a 24-hour period, the labeling may state...

  4. 21 CFR 350.50 - Labeling of antiperspirant drug products.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... following: “dampness,” “perspiration,” “sweat,” “sweating,” or “wetness”]. (2) The labeling may state “also...: ‘dampness,’ ‘perspiration,’ ‘sweat,’ ‘sweating,’ or ‘wetness’] due to stress”. (3) For products that demonstrate standard effectiveness (20 percent sweat reduction) over a 24-hour period, the labeling may state...

  5. 21 CFR 350.50 - Labeling of antiperspirant drug products.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... following: “dampness,” “perspiration,” “sweat,” “sweating,” or “wetness”]. (2) The labeling may state “also...: ‘dampness,’ ‘perspiration,’ ‘sweat,’ ‘sweating,’ or ‘wetness’] due to stress”. (3) For products that demonstrate standard effectiveness (20 percent sweat reduction) over a 24-hour period, the labeling may state...

  6. Abnormal sudomotor function in the hypomelanotic macules of tuberous sclerosis complex.

    PubMed

    Chudnow, R S; Wolfe, G I; Sparagana, S P; Delgado, M R; Batchelor, L; Roach, E S

    2000-08-01

    To investigate the integrity of sympathetic innervation in the hypomelanotic macules of tuberous sclerosis complex, we studied sudomotor function in nine patients with tuberous sclerosis complex. Postganglionic sudomotor function was assessed using the Silastic imprint test in nine patients with tuberous sclerosis complex who have at least one hypomelanotic macule greater than 2 cm in diameter. Sweating was induced by iontophoresis with 0.5% pilocarpine nitrate and sweat droplets were counted under a microscope using a 1 x 1 cm grid. Silastic imprint testing of an analogous skin area contralateral to the hypomelanotic macule was measured as a control. Sweat volume quantitation using sweat collectors was performed in five of the subjects. The sweat volume collected from the hypomelanotic macule was reduced compared to the control skin in four of the five subjects. Sweat droplet counts from the hypomelanotic macule were significantly reduced in only one of nine subjects. These data suggest that, although there is no difference in the number of functioning sweat glands in most hypomelanotic macules, the sweat glands produce less sweat (ie, decreased sweat volume) than in normal skin. We hypothesize that focal abnormalities of sympathetic innervation might be responsible for the hypomelanotic macules of tuberous sclerosis complex.

  7. Sweating the small stuff: Glycoproteins in human sweat and their unexplored potential for microbial adhesion.

    PubMed

    Peterson, Robyn A; Gueniche, Audrey; Adam de Beaumais, Ségolène; Breton, Lionel; Dalko-Csiba, Maria; Packer, Nicolle H

    2016-03-01

    There is increasing evidence that secretory fluids such as tears, saliva and milk play an important role in protecting the human body from infection via a washing mechanism involving glycan-mediated adhesion of potential pathogens to secretory glycoproteins. Interaction of sweat with bacteria is well established as the cause of sweat-associated malodor. However, the role of sweat glycoproteins in microbial attachment has received little, if any, research interest in the past. In this review, we demonstrate how recent published studies involving high-throughput proteomic analysis have inadvertently, and fortuitously, exposed an abundance of glycoproteins in sweat, many of which have also been identified in other secretory fluids. We bring together research demonstrating microbial adhesion to these secretory glycoproteins in tears, saliva and milk and suggest a similar role of the sweat glycoproteins in mediating microbial attachment to sweat and/or skin. The contribution of glycan-mediated microbial adhesion to sweat glycoproteins, and the associated impact on sweat derived malodor and pathogenic skin infections are unchartered new research areas that we are beginning to explore. © The Author 2015. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  8. Sex differences in amino acids lost via sweating could lead to differential susceptibilities to disturbances in nitrogen balance and collagen turnover.

    PubMed

    Dunstan, R H; Sparkes, D L; Dascombe, B J; Stevens, C J; Murphy, G R; Macdonald, M M; Gottfries, J; Gottfries, C-G; Roberts, T K

    2017-08-01

    Fluid collected during sweating is enriched with amino acids derived from the skin's natural moisturising factors and has been termed "faux" sweat. Little is known about sex differences in sweat amino acid composition or whether faux sweat amino acid losses affect nitrogen balance. Faux sweat collected by healthy adults (n = 47) after exercise, and at rest by chronic fatigue patients, was analysed for amino acid composition. Healthy females had higher total amino acid concentrations in sweat (10.5 ± 1.2 mM) compared with healthy males (6.9 ± 0.9 mM). Females had higher levels of 13 amino acids in sweat including serine, alanine and glycine. Higher hydroxyproline and proline levels suggested greater collagen turnover in females. Modelling indicated that with conservative levels of exercise, amino acid losses in females via faux sweat were triple than those predicted for urine, whereas in males they were double. It was concluded that females were more susceptible to key amino acid loss during exercise and/or hot conditions. Females reporting chronic fatigue had higher levels of methionine in faux sweat than healthy females. Males reporting chronic fatigue had higher levels of numerous amino acids in faux sweat compared to healthy males. Higher amino acid loss in faux sweat associated with chronic fatigue could contribute to a hypometabolic state. Depending on activity levels, climatic conditions and gender, amino acid losses in sweat and skin leachate could influence daily protein turnover where periods of continuously high turnover could lead to a negative net nitrogen balance.

  9. A NEW METHOD OF SWEAT TESTING: THE CF QUANTUM® SWEAT TEST

    PubMed Central

    Rock, Michael J.; Makholm, Linda; Eickhoff, Jens

    2015-01-01

    Background Conventional methods of sweat testing are time consuming and have many steps that can and do lead to errors. This study compares conventional sweat testing to a new quantitative method, the CF Quantum® (CFQT) sweat test. This study tests the diagnostic accuracy and analytic validity of the CFQT. Methods Previously diagnosed CF patients and patients who required a sweat test for clinical indications were invited to have the CFQT test performed. Both conventional sweat testing and the CFQT were performed bilaterally on the same day. Pairs of data from each test are plotted as a correlation graph and Bland Altman plot. Sensitivity and specificity were calculated as well as the means and coefficient of variation by test and by extremity. After completing the study, subjects or their parents were asked for their preference of the CFQT and conventional sweat testing. Results The correlation coefficient between the CFQT and conventional sweat testing was 0.98 (95% confidence interval: 0.97–0.99). The sensitivity and specificity of the CFQT in diagnosing CF was 100% (95% confidence interval: 94–100%) and 96% (95% confidence interval: 89–99%), respectively. In one center in this three center multicenter study, there were higher sweat chloride values in patients with CF and also more tests that were invalid due to discrepant values between the two extremities. The percentage of invalid tests was higher in the CFQT method (16.5%) compared to conventional sweat testing (3.8%)(p < 0.001). In the post-test questionnaire, 88% of subjects/parents preferred the CFQT test. Conclusions The CFQT is a fast and simple method of quantitative sweat chloride determination. This technology requires further refinement to improve the analytic accuracy at higher sweat chloride values and to decrease the number of invalid tests. PMID:24862724

  10. Improved Devices for Collecting Sweat for Chemical Analysis

    NASA Technical Reports Server (NTRS)

    Feeback, Daniel L.; Clarke, Mark S. F.

    2011-01-01

    Improved devices have been proposed for collecting sweat for biochemical analysis especially for determination of the concentration of Ca2+ ions in sweat as a measure of loss of Ca from bones. Unlike commercially available sweat-collection patches used previously in monitoring osteoporosis and in qualitative screening for some drugs, the proposed devices would not allow evaporation of the volatile chemical components (mostly water) of sweat. Moreover, the proposed devices would be designed to enable determination of the volumes of collected sweat. From these volumes and the quantities of Ca2+ and/or other analytes as determined by other means summarized below, one could determine the concentrations of the analytes in sweat. A device according to the proposal would be flexible and would be worn like a commercial sweat-collection patch. It would be made of molded polydimethylsiloxane (silicone rubber) or other suitable material having properties that, for the purpose of analyzing sweat, are similar to those of glass. The die for molding the silicone rubber would be fabricated by a combination of lithography and electroplating. The die would reproducibly form, in the silicone rubber, a precisely defined number of capillary channels per unit area, each channel having a precisely defined volume. Optionally, electrodes for measuring the Ca2+ content of the sweat could be incorporated into the device. The volume of sweat collected in the capillary channels of the device would be determined from (1) the amount of light or radio waves of a given wavelength absorbed by the device and (2) the known geometry of the array of capillary channels. Then, in one of two options, centrifugation would be performed to move the sweat from the capillary tubes to the region containing the electrodes, which would be used to measure the Ca2+ content by a standard technique. In the other option, centrifugation would be performed to remove the sweat from the device to make the sweat available to other analytical instruments for measuring concentrations of substances other than Ca2+.

  11. Improved Devices for Collecting Sweat for Chemical Analysis

    NASA Technical Reports Server (NTRS)

    Feedback, Daniel L.; Clarke, Mark S. F.

    2011-01-01

    Improved devices have been proposed for collecting sweat for biochemical analysis - especially for determination of the concentration of Ca2+ ions in sweat as a measure of loss of Ca from bones. Unlike commercially available sweat-collection patches used previously in monitoring osteoporosis and in qualitative screening for some drugs, the proposed devices would not allow evaporation of the volatile chemical components (mostly water) of sweat. Moreover, the proposed devices would be designed to enable determination of the volumes of collected sweat. From these volumes and the quantities of Ca(2+) and/or other analytes as determined by other means summarized below, one could determine the concentrations of the analytes in sweat. A device according to the proposal would be flexible and would be worn like a commercial sweat-collection patch. It would be made of molded polydimethylsiloxane (silicone rubber) or other suitable material having properties that, for the purpose of analyzing sweat, are similar to those of glass. The die for molding the silicone rubber would be fabricated by a combination of lithography and electroplating. The die would reproducibly form, in the silicone rubber, a precisely defined number of capillary channels per unit area, each channel having a precisely defined volume. Optionally, electrodes for measuring the Ca(2+) content of the sweat could be incorporated into the device. The volume of sweat collected in the capillary channels of the device would be determined from (1) the amount of light or radio waves of a given wavelength absorbed by the device and (2) the known geometry of the array of capillary channels. Then, in one of two options, centrifugation would be performed to move the sweat from the capillary tubes to the region containing the electrodes, which would be used to measure the Ca(2+) content by a standard technique. In the other option, centrifugation would be performed to remove the sweat from the device to make the sweat available to other analytical instruments for measuring concentrations of substances other than Ca(2+).

  12. Laboratory performance of sweat conductivity for the screening of cystic fibrosis.

    PubMed

    Greaves, Ronda F; Jolly, Lisa; Massie, John; Scott, Sue; Wiley, Veronica C; Metz, Michael P; Mackay, Richard J

    2018-03-28

    There are several complementary English-language guidelines for the performance of the sweat chloride test. These guidelines also incorporate information for the collection of conductivity samples. However, recommendations for the measurement and reporting of sweat conductivity are less clear than for sweat chloride. The aim of the study was to develop an understanding of the testing and reporting practices of sweat conductivity in Australasian laboratories. A survey specifically directed at conductivity testing was sent to the 12 laboratories registered with the Royal College of Pathologists of Australasia Quality Assurance Programs. Nine (75%) laboratories participated in the survey, seven of whom used Wescor Macroduct® for collecting sweat and the Wescor SWEAT·CHEK™ for conductivity testing, and the remaining two used the Wescor Nanoduct®. There was considerable variation in frequency and staffing for this test. Likewise, criteria about which patients it was inappropriate to test, definitions of adequate collection sweat rate, cutoffs and actions recommended on the basis of the result showed variations between laboratories. Variations in sweat conductivity testing and reporting reflect many of the same issues that were revealed in sweat chloride test audits and have the potential to lead to uncertainty about the result and the proper action in response to the result. We recommend that sweat testing guidelines should include clearer statements about the use of sweat conductivity.

  13. Sweat as an Efficient Natural Moisturizer.

    PubMed

    Shiohara, Tetsuo; Sato, Yohei; Komatsu, Yurie; Ushigome, Yukiko; Mizukawa, Yoshiko

    2016-01-01

    Although recent research on the pathogenesis of allergic skin diseases such as atopic dermatitis has focused on defects in skin genes important for maintaining skin barrier function, the fact that excreted sweat has an overwhelmingly great capacity to increase skin surface hydration and contains moisturizing factors has long been ignored: the increase in water loss induced by these gene defects could theoretically be compensated fully by a significant increase in sweating. In this review, the dogma postulating the detrimental role of sweat in these diseases has been challenged on the basis of recent findings on the physiological functions of sweat, newly recognized sweat gland-/duct-related skin diseases, and therapeutic approaches to the management of these diseases. We are now beginning to appreciate that sweat glands/ducts are a sophisticated regulatory system. Furthermore, depending on their anatomical location and the degree of the impairment, this system might have a different function: sweating responses in sweat glands/ducts located at the folds in hairy skin such as on the trunk and extremities could function as natural regulators that maintain skin hydration under quiescent basal conditions, in addition to the better-studied thermoregulatory functions, which can be mainly mediated by those at the ridges. The normal functioning of sweat could be disturbed in various inflammatory skin diseases. Thus, we should recognize sweating disturbance as an etiologic factor in the development of these diseases. © 2016 S. Karger AG, Basel.

  14. Thin, Soft, Skin-Mounted Microfluidic Networks with Capillary Bursting Valves for Chrono-Sampling of Sweat.

    PubMed

    Choi, Jungil; Kang, Daeshik; Han, Seungyong; Kim, Sung Bong; Rogers, John A

    2017-03-01

    Systems for time sequential capture of microliter volumes of sweat released from targeted regions of the skin offer the potential to enable analysis of temporal variations in electrolyte balance and biomarker concentration throughout a period of interest. Current methods that rely on absorbent pads taped to the skin do not offer the ease of use in sweat capture needed for quantitative tracking; emerging classes of electronic wearable sweat analysis systems do not directly manage sweat-induced fluid flows for sample isolation. Here, a thin, soft, "skin-like" microfluidic platform is introduced that bonds to the skin to allow for collection and storage of sweat in an interconnected set of microreservoirs. Pressure induced by the sweat glands drives flow through a network of microchannels that incorporates capillary bursting valves designed to open at different pressures, for the purpose of passively guiding sweat through the system in sequential fashion. A representative device recovers 1.8 µL volumes of sweat each from 0.8 min of sweating into a set of separate microreservoirs, collected from 0.03 cm 2 area of skin with approximately five glands, corresponding to a sweat rate of 0.60 µL min -1 per gland. Human studies demonstrate applications in the accurate chemical analysis of lactate, sodium, and potassium concentrations and their temporal variations. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Sweat glucose and GLUT2 expression in atopic dermatitis: Implication for clinical manifestation and treatment

    PubMed Central

    Ono, Emi; Mori, Yuki; Yoshioka, Yoshichika; Nomura, Yuko; Munetsugu, Takichi; Yokozeki, Hiroo; Katayama, Ichiro

    2018-01-01

    Sweat includes active components and metabolites, which are needed to maintain skin homeostasis. Component changes in sweat derived from atopic dermatitis (AD) have been reported. To investigate the influence of sweat components on the pathogenesis of AD, we performed a multifaceted assessment, including nuclear magnetic resonance spectroscopy-based metabolomic analysis, and linked these features to clinical features of AD. Distinctive properties of AD sweat are the quite-variation in protein, anti-microbial peptides and glucose concentrations. pH, sodium, and other salt levels in sweat of AD were comparable to that of healthy subjects. Sweat from AD patients with acute inflammation had a more prominent increase in glucose concentration than sweat from healthy individuals or those with AD with chronic inflammation. Topical glucose application delayed recovery of transepidermal water loss in barrier-disrupted mice. Furthermore, the glucose transporter GLUT2 was highly expressed in the lumen of sweat glands from AD patients. AD patients with chronic inflammation had significantly increased GLUT2 mRNA expression and near normal sweat glucose levels. Despite the small sample size in our study, we speculate that the increased glucose levels might be affected by AD severity and phenotype. We hope that this report will bring novel insight into the impact of sweat components on the clinical manifestation of AD. PMID:29677207

  16. Exercise can be pyrogenic in humans.

    PubMed

    Bradford, Carl D; Cotter, James D; Thorburn, Megan S; Walker, Robert J; Gerrard, David F

    2007-01-01

    Exercise increases mean body temperature (T(body)) and cytokine concentrations in plasma. Cytokines facilitate PG production via cyclooxygenase (COX) enzymes, and PGE(2) can mediate fever. Therefore, we used a COX-2 inhibitor to test the hypothesis that PG-mediated pyrogenicity may contribute to the raised T(body) in exercising humans. In a double-blind, cross-over design, 10 males [age: 23 yr (SD 5), Vo(2 max): 53 ml x kg(-1) x min(-1) (SD 5)] consumed rofecoxib (50 mg/day; NSAID) or placebo (PLAC) for 6 days, 2 wk apart. Exercising thermoregulation was measured on day 6 during 45-min running ( approximately 75% Vo(2 max)) followed by 45-min cycling and 60-min seated recovery (28 degrees C, 50% relative humidity). Plasma cytokine (TNF-alpha, IL-10) concentrations were measured at rest and 30-min recovery. T(body) was similar at rest in PLAC (35.59 degrees C) and NSAID (35.53 degrees C) and increased similarly during running, but became 0.33 degrees C (SD 0.26) lower in NSAID during cycling (37.39 degrees C vs. 37.07 degrees C; P = 0.03), and remained lower throughout recovery. Sweating was initiated at T(body) of approximately 35.6 degrees C in both conditions but ceased at higher T(body) in PLAC than NSAID during recovery [36.66 degrees C (SD 0.36) vs. 36.39 degrees C (SD 0.27); P = 0.03]. Cardiac frequency averaged 6 x min(-1) higher in PLAC (P < 0.01), whereas exercising metabolic rate was similar (505 vs. 507 W x m(-2); P = 0.56). A modest increase in both cytokines across exercise was similar between conditions. COX-2 specific NSAID lowered exercising heat and cardiovascular strain and the sweating (offset) threshold, independently of heat production, indicating that PGE-mediated inflammatory processes may contribute to exercising heat strain during endurance exercise in humans.

  17. Characterization of Chemical Constituents of Human Sweat: A Study Based on Indian Population.

    PubMed

    Moulvi, Aafrinnaz; Minz, Pooja; Rath, Subrata; Ashma, Richa

    2018-06-01

    There is a strong evidence in the literature that human odor is unique to an individual; therefore, the focus of this study was to strengthen this evidence through the testing of sweat samples on unrelated individuals with the same ethnicity. Sweat samples were collected from 42 unrelated Indian males and females residing in the same city to determine the chemical constituents in human sweat. The volatile compounds of sweat were subsequently analyzed and identified using gas chromatography-mass spectrometry, and a National Institute of Standards and Technology library was used for individual profiling. A total of 78 compounds were identified in human sweat tested with 22 compounds found to be unique to the individual (frequency of occurrence one). A scent profile, or "chexmotype," unique to the sweat of each individual was obtained. This is the first extensive study on an Indian population with 36 new compounds detected in human sweat.

  18. Determination of selected fatty acids in dried sweat spot using gas chromatography with flame ionization detection.

    PubMed

    Kanďár, Roman; Drábková, Petra; Andrlová, Lenka; Kostelník, Adam; Čegan, Alexander

    2016-11-01

    A method is described for the determination of fatty acids in dried sweat spot and plasma samples using gas chromatography with flame ionization detection. Plasma and dried sweat spot samples were obtained from a group of blood donors. The sweat was collected from each volunteer during exercise. Sweat was spotted onto collection paper containing butylated hydroxytoluene. Fatty acids were derivatized with acetyl chloride in methanol to form methyl esters of fatty acids. The fatty acids in dried sweat spot samples treated with butylated hydroxytoluene and stored at -20°C were stable for 3 months. Our results indicate that sweat contains, among fatty acids with short chain, also fatty acids with long chain and unsaturated fatty acids. Linear relationships between percentage content of selected fatty acids in dried sweat spot and plasma were observed. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. Mild dehydration and cycling performance during 5-kilometer hill climbing.

    PubMed

    Bardis, Costas N; Kavouras, Stavros A; Arnaoutis, Giannis; Panagiotakos, Demosthenes B; Sidossis, Labros S

    2013-01-01

    Hydration has been shown to be an important factor in performance; however, the effects of mild dehydration during intense cycling are not clear. To determine the influence of mild dehydration on cycling performance during an outdoor climbing trial in the heat (ambient temperature = 29.0°C ± 2.2°C). Crossover study. Outdoor. Ten well-trained, male endurance cyclists (age = 28 ± 5 years, height = 182 ± 0.4 cm, mass = 73 ± 4 kg, maximal oxygen uptake = 56 ± 9 mL·min(-1)·kg(-1), body fat = 23% ± 2%, maximal power = 354 ± 48 W). Participants completed 1 hour of steady-state cycling with or without drinking to achieve the desired pre-exercise hydration level before 5-km hill-climbing cycling. Participants started the 5-km ride either euhydrated (EUH) or dehydrated by -1% of body mass (DEH). Performance time, core temperature, sweat rate, sweat sensitivity, and rating of perceived exertion (RPE). Participants completed the 5-km ride 5.8% faster in the EUH (16.6 ± 2.3 minutes) than DEH (17.6 ± 2.9 minutes) trial (t1 = 10.221, P = .001). Postexercise body mass was -1.4% ± 0.3% for the EUH trial and -2.2% ± 0.2% for the DEH trial (t1 = 191.384, P < .001). Core temperature after the climb was greater during the DEH (39.2°C ± 0.3°C) than EUH (38.8°C ± 0.2°C) trial (t1 = 8.04, P = .005). Sweat rate was lower during the DEH (0.44 ± 0.16 mg·m(-2)·s(-1)) than EUH (0.51 ± 0.16 mg·m(-2)·s(-1)) trial (t8 = 2.703, P = .03). Sweat sensitivity was lower during the DEH (72.6 ± 32 g·°C(-1)·min(-1)) than EUH (102.6 ± 54.2 g·°C(-1)·min(-1)) trial (t8 = 3.072, P = .02). Lastly, RPE after the exercise performance test was higher for the DEH (19.0 ± 1.0) than EUH (17.0 ± 1.0) participants (t9 = -3.36, P = .008). We found mild dehydration decreased cycling performance during a 5-km outdoor hill course, probably due to greater heat strain and greater perceived intensity.

  20. Evaluating performance in sweat testing in medical biochemistry laboratories in Croatia.

    PubMed

    Aralica, Merica; Krleza, Jasna Lenicek

    2017-02-15

    Sweat test has a diagnostic role in evaluation of cystic fibrosis. Its performance includes sweat stimulation, collection and analysis. All listed may be sources of inconsistencies in everyday practice. The aim of this study was an evaluation of external quality assessment (EQA) of sweat chloride measurement including sweat test performance in medical biochemistry laboratories in Croatia. EQA for sweat chloride measurement was provided by Croatian Centre for Quality Assessment in Laboratory Medicine (CROQALM) in five consecutive exercises to medical biochemistry laboratories (MBL) that offered sweat testing. A questionnaire regarding all phases of testing was mailed to involved MBL (N = 10). Survey results were compared to current guidelines for sweat test performance. Reported results of EQA in 2015 exercises showed coefficients of variation (CV) from 28.9%, 29.0% to 35.3%, respectively. An introduction of uniform sweat chloride measurement protocol resulted in CV of 15.5% and 14.7% reported in following two exercises in 2016. All MBL included in this study replied to the questionnaire. Results reported by MBL indicated: lack of patient information policy (7/10), use of unacceptable electrodes (6/9), misuse of minimum of acceptable sweat weight (6/9), lack of internal quality assessment (5/9) and recommended reference ranges (5/9 and 4/9). Agreements to guidelines were found in approach to unsuitable patients (9/10) and sweat collection (8/9). Presented results indicate major weak points of current practice in sweat test performance in Croatian MBL and stress the need for its standardization on a national level.

  1. Evaluating performance in sweat testing in medical biochemistry laboratories in Croatia

    PubMed Central

    Aralica, Merica; Krleza, Jasna Lenicek

    2017-01-01

    Introduction Sweat test has a diagnostic role in evaluation of cystic fibrosis. Its performance includes sweat stimulation, collection and analysis. All listed may be sources of inconsistencies in everyday practice. The aim of this study was an evaluation of external quality assessment (EQA) of sweat chloride measurement including sweat test performance in medical biochemistry laboratories in Croatia. Materials and methods EQA for sweat chloride measurement was provided by Croatian Centre for Quality Assessment in Laboratory Medicine (CROQALM) in five consecutive exercises to medical biochemistry laboratories (MBL) that offered sweat testing. A questionnaire regarding all phases of testing was mailed to involved MBL (N = 10). Survey results were compared to current guidelines for sweat test performance. Results Reported results of EQA in 2015 exercises showed coefficients of variation (CV) from 28.9%, 29.0% to 35.3%, respectively. An introduction of uniform sweat chloride measurement protocol resulted in CV of 15.5% and 14.7% reported in following two exercises in 2016. All MBL included in this study replied to the questionnaire. Results reported by MBL indicated: lack of patient information policy (7/10), use of unacceptable electrodes (6/9), misuse of minimum of acceptable sweat weight (6/9), lack of internal quality assessment (5/9) and recommended reference ranges (5/9 and 4/9). Agreements to guidelines were found in approach to unsuitable patients (9/10) and sweat collection (8/9). Conclusion Presented results indicate major weak points of current practice in sweat test performance in Croatian MBL and stress the need for its standardization on a national level. PMID:28392735

  2. Normative data for regional sweat sodium concentration and whole-body sweating rate in athletes.

    PubMed

    Baker, Lindsay B; Barnes, Kelly A; Anderson, Melissa L; Passe, Dennis H; Stofan, John R

    2016-01-01

    The purpose of this study was to establish normative data for regional sweat sodium concentration ([Na+]) and whole-body sweating rate in athletes. Data from 506 athletes (367 adults, 139 youth; 404 male, 102 female) were compiled from observational athlete testing for a retrospective analysis. The participants were skill/team-sport (including American football, baseball, basketball, soccer and tennis) and endurance (including cycling, running and triathlon) athletes exercising in cool to hot environmental conditions (15-50 °C) during training or competition in the laboratory or field. A standardised regional absorbent patch technique was used to determine sweat [Na+] on the dorsal mid-forearm. Whole-body sweat [Na+] was predicted using a published regression equation (y = 0.57x+11.05). Whole-body sweating rate was calculated from pre- to post-exercise change in body mass, corrected for fluid/food intake (ad libitum) and urine output. Data are expressed as mean ± SD (range). Forearm sweat [Na+] and predicted whole-body sweat [Na+] were 43.6 ± 18.2 (12.6-104.8) mmol · L(-1) and 35.9 ± 10.4 (18.2-70.8) mmol · L(-1), respectively. Absolute and relative whole-body sweating rates were 1.21 ± 0.68 (0.26-5.73) L · h(-1) and 15.3 ± 6.8 (3.3-69.7) ml · kg(-1) · h(-1), respectively. This retrospective analysis provides normative data for athletes' forearm and predicted whole-body sweat [Na+] as well as absolute and relative whole-body sweating rate across a range of sports and environmental conditions.

  3. Acetylcholine released from cholinergic nerves contributes to cutaneous vasodilation during heat stress

    NASA Technical Reports Server (NTRS)

    Shibasaki, Manabu; Wilson, Thad E.; Cui, Jian; Crandall, Craig G.

    2002-01-01

    Nitric oxide (NO) contributes to active cutaneous vasodilation during a heat stress in humans. Given that acetylcholine is released from cholinergic nerves during whole body heating, coupled with evidence that acetylcholine causes vasodilation via NO mechanisms, it is possible that release of acetylcholine in the dermal space contributes to cutaneous vasodilation during a heat stress. To test this hypothesis, in seven subjects skin blood flow (SkBF) and sweat rate were simultaneously monitored over three microdialysis membranes placed in the dermal space of dorsal forearm skin. One membrane was perfused with the acetylcholinesterase inhibitor neostigmine (10 microM), the second membrane was perfused with the NO synthase inhibitor N(G)-nitro-l-arginine methyl ester (l-NAME; 10 mM) dissolved in the aforementioned neostigmine solution (l-NAME(Neo)), and the third membrane was perfused with Ringer solution as a control site. Each subject was exposed to approximately 20 min of whole body heating via a water-perfused suit, which increased mean body temperature from 36.4 +/- 0.1 to 37.5 +/- 0.1 degrees C (P < 0.05). After the heat stress, SkBF at each site was normalized to its maximum value, identified by administration of 28 mM sodium nitroprusside. Mean body temperature threshold for cutaneous vasodilation was significantly lower at the neostigmine-treated site relative to the other sites (neostigmine: 36.6 +/- 0.1 degrees C, l-NAME(Neo): 37.1 +/- 0.1 degrees C, control: 36.9 +/- 0.1 degrees C), whereas no significant threshold difference was observed between the l-NAME(Neo)-treated and control sites. At the end of the heat stress, SkBF was not different between the neostigmine-treated and control sites, whereas SkBF at the l-NAME(Neo)-treated site was significantly lower than the other sites. These results suggest that acetylcholine released from cholinergic nerves is capable of modulating cutaneous vasodilation via NO synthase mechanisms early in the heat stress but not after substantial cutaneous vasodilation.

  4. Thermophysiological Responses of Human Volunteers to Whole Body RF Exposure at 220 MHz

    DTIC Science & Technology

    2005-05-19

    could make judgments of sensations and the test. A Fiso temperature probe was also taped to the thermal comfort at intervals during the test (cf. Table...general trends in individual responses. These responses sensation, thermal comfort , perceived sweating, and included six skin temperatures and weighted...Tankle). similar fashion, mean judgments of thermal sensation, The two right panels of the figure show M (upper) and thermal comfort , thermal preference

  5. Sweat production during global heating and during isometric exercise in people with diabetes.

    PubMed

    Petrofsky, Jerrold Scott; Lee, Scott; Patterson, Chris; Cole, Melissa; Stewart, Brian

    2005-11-01

    While sweat production in response to heat is impaired in people with diabetes, sweat production has not been examined during isometric exercise. Eight subjects with type 2 diabetes and 9 control subjects exerted a fatiguing isometric contraction of the handgrip muscles at a tension of 40% of the maximum voluntary strength (MVC) after exposure to a 32 deg C environment for 30 min. compared to 10 controls and 10 subjects with diabetes exposed to a 39 deg C environment. Sweat was impaired to all areas of the body during heat exposure in patients with diabetes under both environmental conditions. For example, on the chest, the average sweat rates after exposure to the 32 deg environment was 259.2 +/- 55.2 nanoliters/min in control subjects and 198.3 +/- 46.2 nanoliters/min for subjects with diabetes. Compared to the 32 deg C environment, control subjects increased sweat in all 4 areas proportionally more than subjects with diabetes. Sudomotor rhythm was present in sweat in control subjects at a rate of repetition of 11 and 50 seconds but almost absent in subjects with diabetes. During exercise, sweat rates slowly increased from the beginning to the end of the exercise. But the head of the subjects with diabetes showed hypersweating while the other areas showed diminished sweating compared to control subjects. Thus some of the impairment in sweating may be due to central mechanisms associated with heat sensitivity or in the hypothalamus and not to the sweat glands themselves.

  6. Sweat Therapy.

    ERIC Educational Resources Information Center

    Colmant, Stephen A.; Merta, Rod J.

    2000-01-01

    A study combined group sweating and group counseling. Four adolescent boys with disruptive behavior disorders participated in 12 sweat therapy sessions. They reported the sessions useful for sharing personal concerns and receiving assistance with problem solving. Three boys showed improvement in self-esteem. Advantages of sweat therapy over other…

  7. Exercise-induced trace mineral element concentration in regional versus whole-body wash-down sweat.

    PubMed

    Baker, Lindsay B; Stofan, John R; Lukaski, Henry C; Horswill, Craig A

    2011-06-01

    Simultaneous whole-body wash-down (WBW) and regional skin surface sweat collections were completed to compare regional patch and WBW sweat calcium (Ca), magnesium (Mg), copper (Cu), manganese (Mn), iron (Fe), and zinc (Zn) concentrations. Athletes (4 men, 4 women) cycled in a plastic open-air chamber for 90 min in the heat. Before exercise, the subjects and cycle ergometer (covered in plastic) were washed with deionized water. After the onset of sweating, sterile patches were attached to the forearm, back, chest, forehead, and thigh and removed on saturation. After exercise, the subjects and cycle ergometer were washed with 5 L of 15-mM ammonium sulfate solution to collect all sweat minerals and determine the volume of unevaporated sweat. Control trials were performed to measure mineral contamination in regional and WBW methods. Because background contamination in the collection system was high for WBW Mn, Fe, and Zn, method comparisons were not made for these minerals. After correction for minimal background contamination, WBW sweat [Ca], [Mg], and [Cu] were 44.6 ± 20.0, 9.8 ± 4.8, and 0.125 ± 0.069 mg/L, respectively, and 5-site regional (weighted for local sweat rate and body surface area) sweat [Ca], [Mg], and [Cu] were 59.0 ± 15.9, 14.5 ± 4.8, and 0.166 ± 0.031 mg/L, respectively. Five-site regional [Ca], [Mg], and [Cu] overestimated WBW by 32%, 48%, and 33%, respectively. No individual regional patch site or 5-site regional was significantly correlated with WBW sweat [Ca] (r = -.21, p = .65), [Mg] (r = .49, p = .33), or [Cu] (r = .17, p = .74). In conclusion, regional sweat [Ca], [Mg], and [Cu] are not accurate surrogates for or significantly correlated with WBW sweat composition.

  8. Monitoring cocaine use in substance-abuse-treatment patients by sweat and urine testing.

    PubMed

    Preston, K L; Huestis, M A; Wong, C J; Umbricht, A; Goldberger, B A; Cone, E J

    1999-09-01

    Sweat and urine specimens were collected from 44 methadone-maintenance patients to evaluate the use of sweat testing to monitor cocaine use. Paired sweat patches that were applied and removed weekly (on Tuesdays) were compared with 3-5 consecutive urine specimens collected Mondays, Wednesdays, and Fridays. All patches (N = 930) were extracted in 2.5 mL of solvent and analyzed by ELISA immunoassay (cutoff concentration 10 ng/mL); a subset of patches (N = 591) was also analyzed by gas chromatography-mass spectrometry (GC-MS) for cocaine, benzoylecgonine (BZE), and ecgonine methyl ester (EME) (cutoff concentration 5 ng/mL). Urine specimens were subjected to qualitative analysis by EMIT (cutoff 300 ng/mL) and subsets were analyzed by TDx (semiquantitative, LOD 30 ng/mL) and by GC-MS for cocaine (LOD 5 ng/mL). Results were evaluated to (1) determine the relative amounts of cocaine and its metabolites in sweat; (2) assess replicability in duplicate patches; (3) compare ELISA and GC-MS results for cocaine in sweat; and (4) compare the detection of cocaine use by sweat and urine testing. Cocaine was detected by GC-MS in 99% of ELISA-positive sweat patches; median concentrations of cocaine, BZE, and EME were 378, 78.7, and 74 ng/mL, respectively. Agreement in duplicate patches was approximately 90% by ELISA analysis. The sensitivity, specificity, and efficiency of sweat ELISA cocaine results as compared with sweat GC-MS results were 93.6%, 91.3%, and 93.2%, respectively. The sensitivity, specificity, and efficiency between ELISA sweat patch and EMIT urine results were 97.6%, 60.5%, and 77.7%, respectively. These results support the use of sweat patches for monitoring cocaine use, though further evaluation is needed.

  9. Effect of sweating set rate on clothing real evaporative resistance determined on a sweating thermal manikin in a so-called isothermal condition (T manikin = T a = T r).

    PubMed

    Lu, Yehu; Wang, Faming; Peng, Hui; Shi, Wen; Song, Guowen

    2016-04-01

    The ASTM F2370 (2010) is the only standard with regard to measurement of clothing real evaporative resistance by means of a sweating manikin. However, the sweating set-point is not recommended in the standard. In this study, the effect of sweating rate on clothing real evaporative resistance was investigated on a 34-zone "Newton" sweating thermal manikin in a so-called isothermal condition (T manikin = T a = T r). Four different sweating set rates (i.e., all segments had a sweating rate of 400, 800, 1200 ml/hr ∙ m(2), respectively, and different sweating rates were assigned to different segments) were applied to determine the clothing real evaporative resistance of five clothing ensembles and the boundary air layer. The results indicated that the sweating rate did not affect the real evaporative resistance of clothing ensembles with the absence of strong moisture absorbent layers. For the clothing ensemble with tight cotton underwear, a sweating rate of lower than 400 ml/hr ∙ m(2) is not recommended. This is mainly because the wet fabric "skin" might not be fully saturated and thus led to a lower evaporative heat loss and thereby a higher real evaporative resistance. For vapor permeable clothing, the real evaporative resistance determined in the so-called isothermal condition should be corrected before being used in thermal comfort or heat strain models. However, the reduction of wet thermal insulation due to moisture absorption in different test scenarios had a limited contribution to the effect of sweating rate on the real evaporative resistance.

  10. Fungal protein MGL_1304 in sweat is an allergen for atopic dermatitis patients.

    PubMed

    Hiragun, Takaaki; Ishii, Kaori; Hiragun, Makiko; Suzuki, Hidenori; Kan, Takanobu; Mihara, Shoji; Yanase, Yuhki; Bartels, Joachim; Schröder, Jens-M; Hide, Michihiro

    2013-09-01

    Sweat is a major aggravating factor of atopic dermatitis (AD) and approximately 80% of patients with AD show type I hypersensitivity against sweat. To identify and characterize an antigen in sweat that induces histamine release from basophils of patients with AD. Basophil histamine-releasing activity in sweat was purified by a combination of chromatographies, and proteins were analyzed with mass spectrometry. Recombinant proteins of the sweat antigen were generated, and their biological characteristics were studied by immunoblots, histamine release tests, and neutralization assays. We identified a fungal protein, MGL_1304, derived from Malassezia globosa (M globosa) in the purified sweat antigen. Recombinant MGL_1304 induced histamine release from basophils of most of the patients with AD, in accordance with the semi-purified sweat antigen. Moreover, recombinant MGL_1304 abolished the binding of serum IgE of patients with AD to the semi-purified sweat antigen, or vice versa in immunoblot analysis, and attenuated the sensitization of RBL-48 mast cells expressing human FcɛRI by serum IgE. Studies of truncated mutants of MGL_1304 indicated that IgE of patients with AD recognized the conformational structure of MGL_1304 rather than short peptide sequences. Western blot analysis of the whole lysate, the culture supernatant of M globosa, and the semi-purified sweat antigen showed that MGL_1304 was produced as a minor immunological antigen of M globosa with posttranslational modification, cleaved, and secreted as a 17-kDa major histamine-releasing sweat antigen. MGL_1304 is a major allergen in human sweat and could cause type I allergy in patients with AD. Copyright © 2013 American Academy of Allergy, Asthma & Immunology. Published by Mosby, Inc. All rights reserved.

  11. Three-dimensional cell shapes and arrangements in human sweat glands as revealed by whole-mount immunostaining

    PubMed Central

    Kurata, Ryuichiro; Futaki, Sugiko; Nakano, Itsuko; Fujita, Fumitaka; Tanemura, Atsushi; Murota, Hiroyuki; Katayama, Ichiro; Okada, Fumihiro

    2017-01-01

    Because sweat secretion is facilitated by mechanical contraction of sweat gland structures, understanding their structure-function relationship could lead to more effective treatments for patients with sweat gland disorders such as heat stroke. Conventional histological studies have shown that sweat glands are three-dimensionally coiled tubular structures consisting of ducts and secretory portions, although their detailed structural anatomy remains unclear. To better understand the details of the three-dimensional (3D) coiled structures of sweat glands, a whole-mount staining method was employed to visualize 3D coiled gland structures with sweat gland markers for ductal luminal, ductal basal, secretory luminal, and myoepithelial cells. Imaging the 3D coiled gland structures demonstrated that the ducts and secretory portions were comprised of distinct tubular structures. Ductal tubules were occasionally bent, while secretory tubules were frequently bent and formed a self-entangled coiled structure. Whole-mount staining of complex coiled gland structures also revealed the detailed 3D cellular arrangements in the individual sweat gland compartments. Ducts were composed of regularly arranged cuboidal shaped cells, while secretory portions were surrounded by myoepithelial cells longitudinally elongated along entangled secretory tubules. Whole-mount staining was also used to visualize the spatial arrangement of blood vessels and nerve fibers, both of which facilitate sweat secretion. The blood vessels ran longitudinally parallel to the sweat gland tubules, while nerve fibers wrapped around secretory tubules, but not ductal tubules. Taken together, whole-mount staining of sweat glands revealed the 3D cell shapes and arrangements of complex coiled gland structures and provides insights into the mechanical contraction of coiled gland structures during sweat secretion. PMID:28636607

  12. A new method of sweat testing: the CF Quantum®sweat test.

    PubMed

    Rock, Michael J; Makholm, Linda; Eickhoff, Jens

    2014-09-01

    Conventional methods of sweat testing are time consuming and have many steps that can and do lead to errors. This study compares conventional sweat testing to a new quantitative method, the CF Quantum® (CFQT) sweat test. This study tests the diagnostic accuracy and analytic validity of the CFQT. Previously diagnosed CF patients and patients who required a sweat test for clinical indications were invited to have the CFQT test performed. Both conventional sweat testing and the CFQT were performed bilaterally on the same day. Pairs of data from each test are plotted as a correlation graph and Bland-Altman plot. Sensitivity and specificity were calculated as well as the means and coefficient of variation by test and by extremity. After completing the study, subjects or their parents were asked for their preference of the CFQT and conventional sweat testing. The correlation coefficient between the CFQT and conventional sweat testing was 0.98 (95% confidence interval: 0.97-0.99). The sensitivity and specificity of the CFQT in diagnosing CF was 100% (95% confidence interval: 94-100%) and 96% (95% confidence interval: 89-99%), respectively. In one center in this three center multicenter study, there were higher sweat chloride values in patients with CF and also more tests that were invalid due to discrepant values between the two extremities. The percentage of invalid tests was higher in the CFQT method (16.5%) compared to conventional sweat testing (3.8%) (p < 0.001). In the post-test questionnaire, 88% of subjects/parents preferred the CFQT test. The CFQT is a fast and simple method of quantitative sweat chloride determination. This technology requires further refinement to improve the analytic accuracy at higher sweat chloride values and to decrease the number of invalid tests. Copyright © 2014 European Cystic Fibrosis Society. Published by Elsevier B.V. All rights reserved.

  13. A Little CFTR Goes a Long Way: CFTR-Dependent Sweat Secretion from G551D and R117H-5T Cystic Fibrosis Subjects Taking Ivacaftor

    PubMed Central

    Char, Jessica E.; Wolfe, Marlene H.; Cho, Hyung-ju; Park, Il-Ho; Jeong, Jin Hyeok; Frisbee, Eric; Dunn, Colleen; Davies, Zoe; Milla, Carlos; Moss, Richard B.; Thomas, Ewart A. C.; Wine, Jeffrey J.

    2014-01-01

    To determine if oral dosing with the CFTR-potentiator ivacaftor (VX-770, Kalydeco) improves CFTR-dependent sweating in CF subjects carrying G551D or R117H-5T mutations, we optically measured sweat secretion from 32–143 individually identified glands in each of 8 CF subjects; 6 F508del/G551D, one G551D/R117H-5T, and one I507del/R117H-5T. Two subjects were tested only (−) ivacaftor, 3 only (+) ivacaftor and 3 (+/−) ivacaftor (1–5 tests per condition). The total number of gland measurements was 852 (−) ivacaftor and 906 (+) ivacaftor. A healthy control was tested 4 times (51 glands). For each gland we measured both CFTR-independent (M-sweat) and CFTR-dependent (C-sweat); C-sweat was stimulated with a β-adrenergic cocktail that elevated [cAMP]i while blocking muscarinic receptors. Absent ivacaftor, almost all CF glands produced M-sweat on all tests, but only 1/593 glands produced C-sweat (10 tests, 5 subjects). By contrast, 6/6 subjects (113/342 glands) produced C-sweat in the (+) ivacaftor condition, but with large inter-subject differences; 3–74% of glands responded with C/M sweat ratios 0.04%–2.57% of the average WT ratio of 0.265. Sweat volume losses cause proportionally larger underestimates of CFTR function at lower sweat rates. The losses were reduced by measuring C/M ratios in 12 glands from each subject that had the highest M-sweat rates. Remaining losses were estimated from single channel data and used to correct the C/M ratios, giving estimates of CFTR function (+) ivacaftor  = 1.6%–7.7% of the WT average. These estimates are in accord with single channel data and transcript analysis, and suggest that significant clinical benefit can be produced by low levels of CFTR function. PMID:24520399

  14. Chloride and sodium ion concentrations in saliva and sweat as a method to diagnose cystic fibrosis.

    PubMed

    Gonçalves, Aline Cristina; Marson, Fernando Augusto Lima; Mendonça, Regina Maria Holanda; Bertuzzo, Carmen Sílvia; Paschoal, Ilma Aparecida; Ribeiro, José Dirceu; Ribeiro, Antônio Fernando; Levy, Carlos Emílio

    2018-05-19

    Cystic fibrosis diagnosis is dependent on the chloride ion concentration in the sweat test (≥60mEq/mL - recognized as the gold standard indicator for cystic fibrosis diagnosis). Moreover, the salivary glands express the CFTR protein in the same manner as sweat glands. Given this context, the objective was to verify the correlation of saliva chloride concentration and sweat chloride concentration, and between saliva sodium concentration and sweat sodium concentration, in patients with cystic fibrosis and healthy control subjects, as a tool for cystic fibrosis diagnosis. There were 160 subjects enrolled: 57/160 (35.70%) patients with cystic fibrosis and two known CFTR mutations and 103/160 (64.40%) healthy controls subjects. Saliva ion concentration was analyzed by ABL 835 Radiometer ® equipment and, sweat chloride concentration and sweat sodium concentration, respectively, by manual titration using the mercurimetric procedure of Schales & Schales and flame photometry. Statistical analysis was performed by the chi-squared test, the Mann-Whitney test, and Spearman's correlation. Alpha=0.05. Patients with cystic fibrosis showed higher values of sweat chloride concentration, sweat sodium concentration, saliva chloride concentration, and saliva sodium concentration than healthy controls subjects (p-value<0.001). The correlation between saliva chloride concentration and sweat chloride concentration showed a positive Spearman's Rho (correlation coefficient)=0.475 (95% CI=0.346 to 0.587). Also, the correlation between saliva sodium concentration and sweat sodium concentration showed a positive Spearman's Rho=0.306 (95% CI=0.158 to 0.440). Saliva chloride concentration and saliva sodium concentration are candidates to be used in cystic fibrosis diagnosis, mainly in cases where it is difficult to achieve the correct sweat amount, and/or CFTR mutation screening is difficult, and/or reference methods for sweat test are unavailable to implement or are not easily accessible by the general population. Copyright © 2018 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.

  15. Sweat Allergy.

    PubMed

    Hiragun, Takaaki; Hide, Michihiro

    2016-01-01

    For many years, sweat has been recognized as an exacerbation factor in all age groups of atopic dermatitis (AD) and a trigger of cholinergic urticaria (CholU). Recently, we reported the improvement of AD symptoms by spray with tannic acid, which suppresses basophil histamine release by semipurified sweat antigens in vitro, and showering that removes antigens in sweat from the skin surface. We finally identified MGL_1304 secreted by Malassezia globosa as a major histamine-releasing antigen in human sweat. MGL_1304 is detected as a 17-kDa protein in sweat and exhibits almost the highest histamine-release ability from basophils of patients with AD and CholU among antigens derived from Malassezia species. Moreover, serum levels of anti-MGL_1304 IgE of patients with AD and CholU were significantly higher than those of normal controls. Desensitization therapy using autologous sweat or MGL_1304 purified from culture of M. globosa or its cognates might be beneficial for patients with intractable CholU due to sweat allergy. © 2016 S. Karger AG, Basel.

  16. Blood electrolytes and exercise in relation to temperature regulation in man

    NASA Technical Reports Server (NTRS)

    Greenleaf, J. E.

    1973-01-01

    Current knowledge and theories about the relation of blood electrolytes and exercise to thermoregulation in man are reviewed. It is shown that the elevation of body temperature during physical exercise is a regulated process and is not due to a failure of the heat dissipating mechanisms. Core and skin temperatures do not provide sufficient information to account for the control of sweating during exercise. Evidence is presented that suggests an association between equilibrium levels of rectal temperature and the osmotic concentration of the blood with essentially no influence of variations in plasma volume.

  17. Acquired defects in CFTR-dependent β-adrenergic sweat secretion in chronic obstructive pulmonary disease

    PubMed Central

    2014-01-01

    Rationale Smoking-induced chronic obstructive pulmonary disease (COPD) is associated with acquired systemic cystic fibrosis transmembrane conductance regulator (CFTR) dysfunction. Recently, sweat evaporimetry has been shown to efficiently measure β-adrenergic sweat rate and specifically quantify CFTR function in the secretory coil of the sweat gland. Objectives To evaluate the presence and severity of systemic CFTR dysfunction in smoking-related lung disease using sweat evaporimetry to determine CFTR-dependent sweat rate. Methods We recruited a cohort of patients consisting of healthy never smokers (N = 18), healthy smokers (12), COPD smokers (25), and COPD former smokers (12) and measured β-adrenergic sweat secretion rate with evaporative water loss, sweat chloride, and clinical data (spirometry and symptom questionnaires). Measurements and main results β-adrenergic sweat rate was reduced in COPD smokers (41.9 ± 3.4, P < 0.05, ± SEM) and COPD former smokers (39.0 ± 5.4, P < 0.05) compared to healthy controls (53.6 ± 3.4). Similarly, sweat chloride was significantly greater in COPD smokers (32.8 ± 3.3, P < 0.01) and COPD former smokers (37.8 ± 6.0, P < 0.01) vs. healthy controls (19.1 ± 2.5). Univariate analysis revealed a significant association between β-adrenergic sweat rate and female gender (β = 0.26), age (−0.28), FEV1% (0.35), dyspnea (−0.3), and history of smoking (−0.27; each P < 0.05). Stepwise multivariate regression included gender (0.39) and COPD (−0.43) in the final model (R2 = 0.266, P < 0.0001). Conclusions β-adrenergic sweat rate was significantly reduced in COPD patients, regardless of smoking status, reflecting acquired CFTR dysfunction and abnormal gland secretion in the skin that can persist despite smoking cessation. β-adrenergic sweat rate and sweat chloride are associated with COPD severity and clinical symptoms, supporting the hypothesis that CFTR decrements have a causative role in COPD pathogenesis. PMID:24568560

  18. Sweat chloride concentrations in children with Idiopathic Nephrotic Syndrome.

    PubMed

    Guglani, Lokesh; Moir, Devin; Jain, Amrish

    2016-01-01

    Idiopathic Nephrotic Syndrome (INS) has been believed to cause a false positive elevation of sweat chloride concentrations, as measured by the sweat test. Sweat tests were done for 11 children with acute onset INS at admission and again while they were in remission, with results being compared to normal historical controls. The initial sweat chloride concentration for 10 patients was normal (mean16.7 ± 11.02 mmol/L) and 1 patient had inadequate collection. This latter patient and two others were excluded during follow-up because of diagnoses other than INS. Sweat test results for the eight INS patients during follow up remained unchanged when they were in remission (16.94 ± 7.88 mmol/L; P = 0.98; Wilcoxon Matched-Pairs Signed Rank Test). In comparing sweat chloride concentrations from INS patients to those from 20 historical control subjects, we found no significant differences (Mann-Whitney Test; initial vs. control P = 0.643; follow up vs. control P = 0.806). INS does not cause a false positive sweat test. Further studies should be done to objectively assess the conditions that have been reported to affect sweat chloride concentrations. © 2015 Wiley Periodicals, Inc.

  19. Sunscreen Use and Sweat Production in Men and Women

    PubMed Central

    Aburto-Corona, Jorge; Aragón-Vargas, Luis

    2016-01-01

    Context: Sunscreen lotions are important to protect the skin during outdoor exercise, but they may interfere with sweating. Objective: To measure the effect of 2 water-resistant sunscreens on local sweat production in men and women exercising in the heat and to compare those effects with the expected inhibition resulting from the use of an antiperspirant. Design: Randomized crossover study. Setting: Exercise in the heat (ambient temperature = 30.2°C ± 0.4°C dry bulb and 58% ± 4.3% relative humidity) in a controlled-environment laboratory. Patients or Other Participants: Twenty physically active, apparently healthy college students, 10 men (age = 22.5 ± 2.8 years, height = 1.771 ± 0.069 m, mass = 70.2 ± 11.0 kg) and 10 women (age = 22.2 ± 3.2 years, height = 1.625 ± 0.075 m, mass = 57.7 ± 7.9 kg). Intervention(s): With sweat-collection patches applied to their right and left scapular regions, the participants performed 2 exercise sessions on consecutive days. We assigned skin treatments (antiperspirant; organic chemical sun filter, sunscreen A; inorganic physical sun block, sunscreen B; no lotion) randomly to side and session. Participants pedaled at 79% ± 1% of maximum heart rate for 20 minutes in the heat. Main Outcome Measure(s): Scapular localized sweat rate. Results: No baseline, environmental, or exercise condition was different among skin treatments. Scapular localized sweat rate was lower for the antiperspirant treatment (88.3 μL/min·dm2; 95% confidence interval [CI] = 82.0, 94.7 μL/min·dm2) and the inorganic physical sun block (sunscreen B) treatment (99.3 μL/min·dm2; 95% CI = 93.1, 105.5 μL/min·dm2) than for the organic chemical sun filter (sunscreen A) treatment (114.8 μL/min·dm2; 95% CI = 108.8, 120.6 μL/min·dm2) or the no-lotion treatment (122.6 μL/min·dm2; 95% CI = 116.2, 129.0 μL/min·dm2; P < .01). Conclusions: The inorganic physical sun block, sunscreen B, hindered effective sweating to the same extent as the antiperspirant, whereas the treatment with the organic chemical sun filter, sunscreen A, was not different from the control treatment. At this stage, it is not possible to identify the specific ingredient responsible for the effect. PMID:27740850

  20. Current concepts of active vasodilation in human skin

    PubMed Central

    Wong, Brett J.; Hollowed, Casey G.

    2017-01-01

    ABSTRACT In humans, an increase in internal core temperature elicits large increases in skin blood flow and sweating. The increase in skin blood flow serves to transfer heat via convection from the body core to the skin surface while sweating results in evaporative cooling of the skin. Cutaneous vasodilation and sudomotor activity are controlled by a sympathetic cholinergic active vasodilator system that is hypothesized to operate through a co-transmission mechanism. To date, mechanisms of cutaneous active vasodilation remain equivocal despite many years of research by several productive laboratory groups. The purpose of this review is to highlight recent advancements in the field of cutaneous active vasodilation framed in the context of some of the historical findings that laid the groundwork for our current understanding of cutaneous active vasodilation. PMID:28349094

  1. Evaluating the impact of breed, pregnancy, and hair coat on body temperature and sweating rate of hair sheep ewes in the tropics.

    PubMed

    Godfrey, R W; Preston, W D; Joseph, S R; LaPlace, L; Hillman, P E; Gebremedhin, K G; Lee, C N; Collier, R J

    2017-07-01

    The objective of this study was to evaluate the effect of pregnancy, breed, and hair coat on body temperature and sweating rate (SR) of hair sheep. St. Croix White (STX; = 9) and Dorper × STX (DRPX; = 9) ewes (3.6 yr of age) were evaluated over 4 d at 126 d of gestation (PREG) and over 4 d at 46 d postpartum (OPEN) in the shade and sun and in the morning (AM; 0900 to 1200 h) and afternoon (PM; 1300 to 1600 h) after a 20 min acclimation to each condition on each day. Data loggers recorded vaginal temperature (VT) at 10-min intervals for 96 h. Rectal temperature (RT) was measured using a digital veterinary thermometer, and respiration rate (RR) was measured as breaths per minute (bpm). Sweating rate was calculated from measured air properties passing over a shaved (300 cm) and unshaved area of the ewes' body using a portable calorimeter. Data were analyzed using GLM procedures of SAS (SAS Inst. Inc., Cary, NC) with breed, pregnancy status, sun exposure, and time of day as main effects. Mean temperature, relative humidity, temperature-humidity index, wind speed, and solar radiation on the days of data collection were 28.2°C, 82.8%, 80.3, 4.2 km/h, and 237.5 W/m, respectively. There was no difference ( > 0.10) in RT, RR, and SR between DRPX and STX ewes. The PREG ewes had lower RT ( < 0.007) and SR ( < 0.0001) and higher RR ( < 0.007) than OPEN ewes (38.5 ± 0.2 vs. 39.1 ± 0.2°C, 70.2 ± 3.1 vs. 88.3 ± 3.1 g⋅m⋅h, and 79.5 ± 2.2 vs. 72.1 ± 2.2 bpm, respectively). During the PM, RR, RT ( < 0.05), and SR ( < 0.006) were higher than in the AM. In the sun, RR ( < 0.001) and SR ( < 0.0001) were higher than in the shade, but there was no difference ( > 0.10) in RT. There was no difference in SR ( > 0.10) between the shaved and unshaved area of the ewe. The DRPX ewes had higher ( < 0.0001) VT than STX ewes. The PREG ewes had higher ( < 0.001) VT than OPEN ewes during the night time and lower VT than the OPEN ewes during the day time ( < 0.0001). The OPEN ewes had a greater ( < 0.009) daily range of VT than PREG ewes did (2.5 ± 0.4 vs. 1.1 ± 0.4°C, respectively), but there was no breed difference ( > 0.10). Hair coat did not have an influence on the SR of the ewes, and PREG ewes appeared to use increased respiration as opposed to sweating to help control RT. The narrower range of body temperature, measured as VT, of PREG compared to OPEN ewes may be a protective mechanism for the developing fetus.

  2. Baroreceptor unloading does not limit forearm sweat rate during severe passive heat stress.

    PubMed

    Schlader, Zachary J; Gagnon, Daniel; Lucas, Rebekah A I; Pearson, James; Crandall, Craig G

    2015-02-15

    This study tested the hypothesis that sweat rate during passive heat stress is limited by baroreceptor unloading associated with heat stress. Two protocols were performed in which healthy subjects underwent passive heat stress that elicited an increase in intestinal temperature of ∼1.8°C. Upon attaining this level of hyperthermia, in protocol 1 (n = 10, 3 females) a bolus (19 ml/kg) of warm (∼38°C) isotonic saline was rapidly (5-10 min) infused intravenously to elevate central venous pressure (CVP), while in protocol 2 (n = 11, 5 females) phenylephrine was infused intravenously (60-120 μg/min) to return mean arterial pressure (MAP) to normothermic levels. In protocol 1, heat stress reduced CVP from 3.9 ± 1.9 mmHg (normothermia) to -0.6 ± 1.4 mmHg (P < 0.001), while saline infusion returned CVP to normothermic levels (5.1 ± 1.7 mmHg; P > 0.999). Sweat rate was elevated by heat stress (1.21 ± 0.44 mg·cm(-2)·min(-1)) but remained unchanged during rapid saline infusion (1.26 ± 0.47 mg·cm(-2)·min(-1), P = 0.5), whereas cutaneous vascular conductance increased from 77 ± 10 to 101 ± 20% of local heating max (P = 0.029). In protocol 2, MAP was reduced with heat stress from 85 ± 7 mmHg to 76 ± 8 mmHg (P = 0.048). Although phenylephrine infusion returned MAP to normothermic levels (88 ± 7 mmHg; P > 0.999), sweat rate remained unchanged during phenylephrine infusion (1.39 ± 0.22 vs. 1.41 ± 0.24 mg·cm(-2)·min(-1); P > 0.999). These data indicate that both cardiopulmonary and arterial baroreceptor unloading do not limit increases in sweat rate during passive heat stress. Copyright © 2015 the American Physiological Society.

  3. Heat removal using microclimate foot cooling: a thermal foot manikin study.

    PubMed

    Castellani, John W; Demes, Robert; Endrusick, Thomas L; Cheuvront, Samuel N; Montain, Scott J

    2014-04-01

    It has been proposed that microclimate cooling systems exploit the peripheral extremities because of more efficient heat transfer. The purpose of this study was to quantify, using a patented microclimate cooling technique, the heat transfer from the plantar surface of the foot for comparison to other commonly cooled body regions. A military boot was fitted with an insole embedded with a coiled, 1.27 m length of hollow tubing terminating in inlet and outlet valves. A thermal foot manikin with a surface temperature of 34 degrees C was placed in the boot and the valves were connected to a system that circulated water through the insole at a temperature of 20 degrees C and flow rate of 120 ml x min(-1). The manikin foot served as a constant heat source to determine heat transfer provided by the insole. Testing was done with the foot model dry and sweating at a rate of 500 ml x h(- 1) x m(-2). Climatic chamber conditions were 30 degrees C with 30% RH. Heat loss was approximately 4.1 +/- 0.1 and approximately 7.7 +/- 0.3 W from the dry and sweating foot models, respectively. On a relative scale, the heat loss was 3.0 W and 5.5 W per 1% (unit) body surface area, respectively, for the dry and sweating conditions. The relative heat loss afforded by plantar foot cooling was similar compared to other body regions, but the absolute amount of heat removal is unlikely to make an impact on whole body heat balance.

  4. Increase in dermcidin-derived peptides in sweat of patients with atopic eczema caused by a humorous video.

    PubMed

    Kimata, Hajime

    2007-01-01

    Dermcidin (DCD)-derived peptide is an antimicrobial peptide produced by the sweat glands. However, the levels of DCD-derived peptide in sweat were decreased in patients with atopic eczema (AE). The effect of viewing a humorous video on the levels of DCD-derived peptide was studied. Twenty patients with AE viewed an 87-min humorous video (Modern Times, featuring Charlie Chaplin). Just before and immediately after viewing, sweat was collected, and the levels of DCD-derived peptide and total protein in sweat were measured. Viewing a humorous video increased the levels of DCD-derived peptide without affecting the levels of total protein in sweat. Viewing a humorous video increased DCD-derived peptide in sweat of patients with AE, and thus, it may be helpful in the treatment of skin infection of AE.

  5. Endocrine concomitants of sweating and sweat depression.

    PubMed

    Candas, V; Brandenberger, G; Lutz-Bucher, B; Follenius, M; Libert, J P

    1984-01-01

    The effect of humid heat (Ta = 43 degrees C, Pa = 32 Torr) on sweat rate, plasma renin activity and plasma levels of aldosterone and antidiuretic hormone (ADH) was studied in four male subjects before and after repeated heat exposures. Over-sweating and sweat drippage followed by hidromeiosis were observed in three subjects during initial heat exposure. With repeated humid heat exposures increased sweat rates were accompanied by a more intense sweat depression (hidromeiosis) in all four subjects. In our conditions, no changes in plasma levels of aldosterone and ADH or plasma renin activity were observed with hidromeiosis. Plasma renin activity was slightly depressed by repeated exposures, whereas plasma volumes were enhanced, with no significant changes in plasma Na or K. The results suggest that neither ADH nor the components of the renin-angiotensin aldosterone system are involved in the hidromeiotic phenomenon.

  6. Sixty-five years since the New York heat wave: advances in sweat testing for cystic fibrosis.

    PubMed

    Collie, Jake T B; Massie, R John; Jones, Oliver A H; LeGrys, Vicky A; Greaves, Ronda F

    2014-02-01

    The sweat test remains important as a diagnostic test for cystic fibrosis (CF) and has contributed greatly to our understanding of CF as a disease of epithelial electrolyte transport. The standardization of the sweat test, by Gibson and Cooke [Gibson and Cooke (1959) Pediatrics 1959;23:5], followed observations of excessive dehydration amongst patients with CF and confirmed the utility as a diagnostic test. Quantitative pilocarpine iontophoresis remains the gold standard for sweat induction, but there are a number of collection and analytical methods. The pathophysiology of electrolyte transport in sweat was described by Quinton [Quinton (1983) Nature 1983;301:421-422], and this complemented the developments in genetics that discovered the cystic fibrosis transmembrane conductance regulator (CFTR), an epithelial-based electrolyte transport protein. Knowledge of CF has since increased rapidly and further developments in sweat testing include: new collection methods, further standardization of the technique with international recommendations and age related reference intervals. More recently, sweat chloride values have been used as proof of effect for the new drugs that activate CFTR. However, there remain issues with adherence to sweat test guidelines in many countries and there are gaps in our knowledge, including reference intervals for some age groups and stability of sweat samples in transport. Furthermore, modern methods of elemental quantification need to be explored as alternatives to the original analytical methods for sweat electrolyte measurement. The purpose of this review is therefore to describe the development of the sweat test and consider future directions. © 2013 Wiley Periodicals, Inc.

  7. Sweat lipid mediator profiling: a non-invasive approach for cutaneous research

    USDA-ARS?s Scientific Manuscript database

    Sweat is a complex biological fluid with potential diagnostic value for the investigation of skin disorders. Previous efforts in sweat testing focused on analysis of small molecules and ions for forensic and diagnostic testing, but with advances in analytical and sweat collection techniques, there h...

  8. Fire fighting and its influence on the body.

    PubMed

    Rossi, René

    2003-08-15

    Working conditions for fire fighters can be described according to the environment temperature and the incident radiant heat flux. Measurements for this study in buildings for fire fighting training have shown that fire fighters are typically exposed to radiant heat fluxes of between 5 and 10 kWm(-2) during this kind of exercise. The heat load can nevertheless be much higher. In one case, 42 kWm(-2) was measured. The temperatures reached between 100 and 190 degrees C at 1 m above ground, going up to 278 degrees C in one case. Human trials have been performed with 17 fire fighters. After exercises (about 15 min) in a heated room, the mean core temperature of the fire fighters rose by 0.6 degrees C with a surrounding temperature of 31 degrees C and 1.0 degrees C with 38 degrees C. The sweat production varied from 0.7 to 2.1 lh(-1); 16% to 45% of sweat remained in the clothing layers. During the exercises in the training buildings, a mean of 48 degrees C has been measured between fire fighters' clothing and workwear. These conditions lead to an increase of the relative humidity in all the jackets up to 100%. When the fire fighters came out of the fire, the humidity remained at this level in the PVC coated jackets while it was in some cases strongly reduced in breathable jackets.

  9. Diagnosing night sweats.

    PubMed

    Viera, Anthon J; Bond, Michael M; Yates, Scott W

    2003-03-01

    Night sweats are a common outpatient complaint, yet literature on the subject is scarce. Tuberculosis and lymphoma are diseases in which night sweats are a dominant symptom, but these are infrequently found to be the cause of night sweats in modern practice. While these diseases remain important diagnostic considerations in patients with night sweats, other diagnoses to consider include human immunodeficiency virus, gastroesophageal reflux disease, obstructive sleep apnea, hyperthyroidism, hypoglycemia, and several less common diseases. Antihypertensives, antipyretics, other medications, and drugs of abuse such as alcohol and heroin may cause night sweats. Serious causes of night sweats can be excluded with a thorough history, physical examination, and directed laboratory and radiographic studies. If a history and physical do not reveal a possible diagnosis, physicians should consider a purified protein derivative, complete blood count, human immunodeficiency virus test, thyroid-stimulating hormone test, erythrocyte sedimentation rate evaluation, chest radiograph, and possibly chest and abdominal computed tomographic scans and bone marrow biopsy.

  10. Sweat Chlorides in Salt-Deprived Cystic Fibrosis Heterozygotes

    PubMed Central

    Myers, Michael F.

    1965-01-01

    Sweat chlorides of 10 sets of parents of children with cystic fibrosis and 11 controls were studied in an attempt to develop a test for the diagnosis of cystic fibrosis heterozygotes by subjecting both the parents and controls to a low sodium diet and comparing sweat chloride values as the diet progressed. It was hoped that the sweat chloride levels of the parents, the heterozygotes, would remain stationary throughout the diet, since their children, the homozygotes, reveal this finding under similar conditions of salt deprivation. The sweat chloride levels of the controls, because of effects of aldosterone, were expected to decrease steadily from the commencement of the diet to its termination. A decrease in sweat chloride values of similar magnitude was found in both parents and controls as the diet continued. It is concluded that the study of sweat electrolyte levels in salt-deprived subjects is of no value in the diagnosis of cystic fibrosis heterozygotes. PMID:14289142

  11. Effects of stimulation technique, anatomical region and time on human sweat lipid mediator profiles.

    USDA-ARS?s Scientific Manuscript database

    Few studies compare sampling protocol effect on sweat composition. Here we evaluate the impact of sweat stimulation mode and site of collection on lipid mediator composition. Sweat from healthy males (n = 7) was collected weekly for three weeks from the volar forearm following either pilocarpine ion...

  12. Sweat Therapy Theory, Practice, and Efficacy

    ERIC Educational Resources Information Center

    Eason, Allen; Colmant, Stephen; Winterowd, Carrie

    2009-01-01

    The purpose of this article is to examine the potential application of sweat rituals to group counseling, adventure therapy, and other forms of group work by describing a theoretical model for how sweat rituals work and presenting the results of a randomized comparative outcome study on the efficacy of sweat therapy. The theoretical model proposes…

  13. 78 FR 57650 - Announcement of Funding Awards for the Self-Help Homeownership Opportunity Program (SHOP) for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-09-19

    ... significant amount of sweat equity towards the development of the SHOP units. Sweat equity involves... SHOP funds together with the homebuyer's sweat equity and volunteer labor contributions significantly... sweat equity contribution must not be mortgaged or otherwise restricted upon future sale of the SHOP...

  14. 40 CFR 63.1506 - Operating requirements.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... an existing sweat furnace that meets the specifications of § 63.1505(f)(1) must operate the sweat... date of this standard. (3) The owner or operator of a new sweat furnace that meets the specifications of § 63.1505(f)(1) must operate the sweat furnace and control equipment according to the requirements...

  15. 40 CFR 63.1506 - Operating requirements.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... an existing sweat furnace that meets the specifications of § 63.1505(f)(1) must operate the sweat... date of this standard. (3) The owner or operator of a new sweat furnace that meets the specifications of § 63.1505(f)(1) must operate the sweat furnace and control equipment according to the requirements...

  16. Crying for a Vision: The Native American Sweat Lodge Ceremony as Therapeutic Intervention

    ERIC Educational Resources Information Center

    Garrett, Michael Tlanusta; Torres-Rivera, Edil; Brubaker, Michael; Portman, Tarrell Awe Agahe; Brotherton, Dale; West-Olatunji, Cirecie; Conwill, William; Grayshield, Lisa

    2011-01-01

    The Native American sweat lodge ceremony or sweat therapy is being used increasingly in various medical, mental health, correctional, and substance abuse treatment centers serving both Native and non-Native clients. This article explores the sweat lodge ceremony's background, elements of Native American spirituality, origin story, cultural…

  17. Distinguishing hyperhidrosis and normal physiological sweat production: new data and review of hyperhidrosis data for 1980-2013.

    PubMed

    Thorlacius, Linnea; Gyldenløve, Mette; Zachariae, Claus; Carlsen, Berit C

    2015-10-01

    Hyperhidrosis is a condition in which the production of sweat is abnormally increased. No objective criteria for the diagnosis of hyperhidrosis exist, mainly because reference intervals for normal physiological sweat production at rest are unknown. The main objective of this study was to establish reference intervals for normal physiological axillary and palmar sweat production. Gravimetric testing was performed in 75 healthy control subjects. Subsequently, these results were compared with findings in a cohort of patients with hyperhidrosis and with the results derived from a review of data on hyperhidrosis published between 1980 and 2013. Approximately 90% of the controls had axillary and palmar sweat production rates of below 100 mg/5 min. In all except one of the axillary and palmar hyperhidrosis studies reviewed, average sweat production exceeded 100 mg/5 min. A sweat production rate of 100 mg/5 min as measured by gravimetric testing may be a reasonable cut-off value for distinguishing axillary and palmar hyperhidrosis from normal physiological sweat production. © 2015 The International Society of Dermatology.

  18. Sweat: a sample with limited present applications and promising future in metabolomics.

    PubMed

    Mena-Bravo, A; Luque de Castro, M D

    2014-03-01

    Sweat is a biofluid with present scant use as clinical sample. This review tries to demonstrate the advantages of sweat over other biofluids such as blood or urine for routine clinical analyses and the potential when related to metabolomics. With this aim, critical discussion of sweat samplers and equipment for analysis of target compounds in this sample is made. Well established routine analyses in sweat as is that to diagnose cystic fibrosis, and the advantages and disadvantages of sweat versus urine or blood for doping control have also been discussed. Methods for analytes such as essential metals and xenometals, ethanol and electrolytes in sweat in fact constitute target metabolomics approaches or belong to any metabolomics subdiscipline such as metallomics, ionomics or xenometabolomics. The higher development of biomarkers based on genomics or proteomics as omics older than metabolomics is discussed and also the potential role of metabolomics in systems biology taking into account its emergent implementation. Normalization of the volume of sampled sweat constitutes a present unsolved shortcoming that deserves investigation. Foreseeable trends in this area are outlined. Copyright © 2013 Elsevier B.V. All rights reserved.

  19. The microfluidics of the eccrine sweat gland, including biomarker partitioning, transport, and biosensing implications

    PubMed Central

    Sonner, Z.; Wilder, E.; Heikenfeld, J.; Kasting, G.; Beyette, F.; Swaile, D.; Sherman, F.; Joyce, J.; Hagen, J.; Kelley-Loughnane, N.; Naik, R.

    2015-01-01

    Non-invasive and accurate access of biomarkers remains a holy grail of the biomedical community. Human eccrine sweat is a surprisingly biomarker-rich fluid which is gaining increasing attention. This is especially true in applications of continuous bio-monitoring where other biofluids prove more challenging, if not impossible. However, much confusion on the topic exists as the microfluidics of the eccrine sweat gland has never been comprehensively presented and models of biomarker partitioning into sweat are either underdeveloped and/or highly scattered across literature. Reported here are microfluidic models for eccrine sweat generation and flow which are coupled with review of blood-to-sweat biomarker partition pathways, therefore providing insights such as how biomarker concentration changes with sweat flow rate. Additionally, it is shown that both flow rate and biomarker diffusion determine the effective sampling rate of biomarkers at the skin surface (chronological resolution). The discussion covers a broad class of biomarkers including ions (Na+, Cl−, K+, NH4+), small molecules (ethanol, cortisol, urea, and lactate), and even peptides or small proteins (neuropeptides and cytokines). The models are not meant to be exhaustive for all biomarkers, yet collectively serve as a foundational guide for further development of sweat-based diagnostics and for those beginning exploration of new biomarker opportunities in sweat. PMID:26045728

  20. Effects of high and low blood lactate concentrations on sweat lactate response.

    PubMed

    Green, J M; Bishop, P A; Muir, I H; McLester, J R; Heath, H E

    2000-11-01

    Sweat lactate results from eccrine gland metabolism, however, the possible clearance of blood lactate through sweat has not been resolved. On separate days in an environmental chamber (32 +/- 1 C) 12 subjects completed a constant load (CON) (30 min at 40% VO2 max) and an interval cycling trial (INT) (15 one-min intervals at 80% VO2 max, each separated by one min rest) each designed to elicit different blood lactate responses. Each 30 min cycling trial was preceded by 15 min warm-up (30 watts) and followed by 15 min passive rest. Sweat and blood were analyzed for lactate concentration at 15, 25, 35, 45, and 60 min during CON and INT. Total body water loss was used to calculate sweat rate (ml/hr). Blood lactate was significantly greater (p < or = 0.05) at 25, 35, 45, and 60 min during INT compared to CON (approximately 5 mmol/L vs 1.5 mmol/L). Sweat lactate was not significantly different (p>0.05) between trials at any time (approximately 10 mmol/L). Sweat rates (approximately 600ml/hr) and estimated total lactate secretion were not significantly different (CON vs. INT) (p > 0.05). Elevated blood lactate was not associated with changes in sweat lactate concentration. Sweat lactate seems to originate in eccrine glands independent of blood lactate.

  1. Comparison of fabric skins for the simulation of sweating on thermal manikins

    NASA Astrophysics Data System (ADS)

    Koelblen, Barbara; Psikuta, Agnes; Bogdan, Anna; Annaheim, Simon; Rossi, René M.

    2017-09-01

    Sweating is an important thermoregulatory process helping to dissipate heat and, thus, to prevent overheating of the human body. Simulations of human thermo-physiological responses in hot conditions or during exercising are helpful for assessing heat stress; however, realistic sweating simulation and evaporative cooling is needed. To this end, thermal manikins dressed with a tight fabric skin can be used, and the properties of this skin should help human-like sweat evaporation simulation. Four fabrics, i.e., cotton with elastane, polyester, polyamide with elastane, and a skin provided by a manikin manufacturer (Thermetrics) were compared in this study. The moisture management properties of the fabrics have been investigated in basic tests with regard to all phases of sweating relevant for simulating human thermo-physiological responses, namely, onset of sweating, fully developed sweating, and drying. The suitability of the fabrics for standard tests, such as clothing evaporative resistance measurements, was evaluated based on tests corresponding to the middle phase of sweating. Simulations with a head manikin coupled to a thermo-physiological model were performed to evaluate the overall performance of the skins. The results of the study showed that three out of four evaluated fabrics have adequate moisture management properties with regard to the simulation of sweating, which was confirmed in the coupled simulation with the head manikin. The presented tests are helpful for comparing the efficiency of different fabrics to simulate sweat-induced evaporative cooling on thermal manikins.

  2. Efficient sweat reduction of three different antiperspirant application forms during stress-induced sweating.

    PubMed

    Schmidt-Rose, T; Lehmbeck, F; Bürger, A; Windisch, B; Keyhani, R; Max, H

    2013-12-01

    Stress sweating can occur in everyday situations independently of thermally-induced perspiration. It is triggered by emotionally challenging situations and leads to underarm wetness and a characteristic unpleasant malodor. In this study, we aimed to determine the long-term efficacy of three unperfumed antiperspirant (AP) formulas for different application forms (roll-on, stick, aerosol) against stress-induced sweating and malodor formation. We utilized the widely accepted Trier Social Stress Test (TSST) to induce psychosocial stress in female and male volunteers (18 - 40 years) and determined physiological stress parameters. To additionally assess the efficacy of the test AP roll-on against thermally-induced sweating, a hot room study was performed. Increasing heart rates and an augmentation of saliva cortisol levels during the TSST indicated a substantial stress reaction which was paralleled by a pronounced sweat production in the untreated axillae of both males and females. Forty-eight hours after application, all three test APs significantly decreased the amount of sweat in the treated axillae independent of gender. With respect to AP effects on malodor production, trained sniffers assessed sweat samples collected during the TSST from the untreated axillae as significantly more malodorous than comparable samples from the AP-treated axillae. Also, independent of gender the test AP roll-on significantly decreased the thermally-induced sweat in the AP-treated axilla. We show for the first time a highly effective reduction of emotionally-induced axillary sweating and malodor production for three different application forms 48 h after the last product use. The specially developed roll-on, stick, and aerosol AP provide long-term protection against stress-induced sweat which is of high relevance in everyday life. © 2013 Society of Cosmetic Scientists and the Société Française de Cosmétologie.

  3. Sweat-inducing physiological challenges do not result in acute changes in hair cortisol concentrations.

    PubMed

    Grass, Juliane; Kirschbaum, Clemens; Miller, Robert; Gao, Wei; Steudte-Schmiedgen, Susann; Stalder, Tobias

    2015-03-01

    Hair cortisol concentrations (HCC) are assumed to provide a stable, integrative marker of long-term systemic cortisol secretion. However, contrary to this assumption, some recent observations have raised the possibility that HCC may be subject to acute influences, potentially related to cortisol incorporation from sweat. Here, we provide a first detailed in vivo investigation of this possibility comprising two independent experimental studies: study I (N=42) used a treadmill challenge to induce sweating together with systemic cortisol reactivity while in study II (N=52) a sauna bathing challenge induced sweating without systemic cortisol changes. In both studies, repeated assessments of HCC, salivary cortisol, cortisol in sweat and individuals' sweating rate (single assessment) were conducted on the experimental day and at a next-day follow-up. Results across the two studies consistently revealed that HCC were not altered by the acute interventions. Further, HCC were found to be unrelated to acute salivary cortisol reactivity, sweat cortisol levels, sweating rate or the time of examination. In line with previous data, cortisol levels in sweat were strongly related to total salivary cortisol output across the examined periods. The present results oppose recent case report data by showing that single sweat-inducing interventions do not result in acute changes in HCC. Our data also tentatively speak against the notion that cortisol in sweat may be a dominant source of HCC. Further, our findings also indicate that HCC are not subject to diurnal variation. This research provides further support for hair cortisol analysis as a marker of integrated long-term systemic cortisol secretion. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. Evidence for metaboreceptor stimulation of sweating in normothermic and heat-stressed humans

    NASA Technical Reports Server (NTRS)

    Shibasaki, M.; Kondo, N.; Crandall, C. G.

    2001-01-01

    1. Isometric handgrip (IHG) exercise increases sweat rate and arterial blood pressure, and both remain elevated during post-exercise ischaemia. The purpose of this study was to identify whether the elevation in arterial blood pressure during post-exercise ischaemia contributes to the increase in sweating. 2. In normothermia and during whole-body heating, 2 min IHG exercise at 40% maximal voluntary contraction, followed by 2 min post-exercise ischaemia, was performed with and without bolus intravenous administration of sodium nitroprusside during the ischaemic period. Sodium nitroprusside was administered to reduce blood pressure during post-exercise ischaemia to pre-exercise levels. Sweat rate was monitored over two microdialysis membranes placed in the dermal space of forearm skin. One membrane was perfused with the acetylcholinesterase inhibitor neostigmine, while the other was perfused with the vehicle. 3. In normothermia, IHG exercise increased sweat rate at the neostigmine-treated site but not at the control site. Sweat rate remained elevated during post-exercise ischaemia even after mean arterial blood pressure returned to the pre-IHG exercise baseline. Subsequent removal of the ischaemia stimulus returned sweat rate to pre-IHG exercise levels. Sweat rate during post-exercise ischaemia without sodium nitroprusside administration followed a similar pattern. 4. During whole-body heating, IHG exercise increased sweat rate at both neostigmine-treated and untreated sites. Similarly, regardless of whether mean arterial blood pressure remained elevated or was reduced during post-exercise ischaemia, sweat rate remained elevated during the ischaemic period. 5. These results suggest that sweating in non-glabrous skin during post-IHG exercise ischaemia is activated by metaboreflex stimulation and not via baroreceptor loading.

  5. Assessment of Correlation between Sweat Chloride Levels and Clinical Features of Cystic Fibrosis Patients.

    PubMed

    Raina, Manzoor A; Khan, Mosin S; Malik, Showkat A; Raina, Ab Hameed; Makhdoomi, Mudassir J; Bhat, Javed I; Mudassar, Syed

    2016-12-01

    Cystic Fibrosis (CF) is an autosomal recessive disorder and the incidence of this disease is undermined in Northern India. The distinguishable salty character of the sweat belonging to individuals suffering from CF makes sweat chloride estimation essential for diagnosis of CF disease. The aim of this prospective study was to elucidate the relationship of sweat chloride levels with clinical features and pattern of CF. A total of 182 patients, with clinical features of CF were included in this study for quantitative measurement of sweat chloride. Sweat stimulation and collection involved pilocarpine iontophoresis based on the Gibson and Cooks methodology. The quantitative estimation of chloride was done by Schales and Schales method with some modifications. Cystic Fibrosis Trans Membrane Conductance Regulator (CFTR) mutation status was recorded in case of patients with borderline sweat chloride levels to correlate the results and for follow-up. Out of 182 patients having clinical features consistent with CF, borderline and elevated sweat chloride levels were present in 9 (5%) and 41 (22.5%) subjects respectively. Elevated sweat chloride levels were significantly associated with wheeze, Failure To Thrive (FTT), history of CF in Siblings, product of Consanguineous Marriage (CM), digital clubbing and steatorrhoea on univariate analysis. On multivariate analysis only wheeze, FTT and steatorrhoea were found to be significantly associated with elevated sweat chloride levels (p<0.05). Among the nine borderline cases six cases were positive for at least two CFTR mutations and rest of the three cases were not having any mutation in CFTR gene. The diagnosis is often delayed and the disease is advanced in most patients at the time of diagnosis. Sweat testing is a gold standard for diagnosis of CF patients as genetic mutation profile being heterozygous and unlikely to become diagnostic test.

  6. In Vivo Readout of CFTR Function: Ratiometric Measurement of CFTR-Dependent Secretion by Individual, Identifiable Human Sweat Glands

    PubMed Central

    Wine, Jeffrey J.; Char, Jessica E.; Chen, Jonathan; Cho, Hyung-ju; Dunn, Colleen; Frisbee, Eric; Joo, Nam Soo; Milla, Carlos; Modlin, Sara E.; Park, Il-Ho; Thomas, Ewart A. C.; Tran, Kim V.; Verma, Rohan; Wolfe, Marlene H.

    2013-01-01

    To assess CFTR function in vivo, we developed a bioassay that monitors and compares CFTR-dependent and CFTR-independent sweat secretion in parallel for multiple (∼50) individual, identified glands in each subject. Sweating was stimulated by intradermally injected agonists and quantified by optically measuring spherical sweat bubbles in an oil-layer that contained dispersed, water soluble dye particles that partitioned into the sweat bubbles, making them highly visible. CFTR-independent secretion (M-sweat) was stimulated with methacholine, which binds to muscarinic receptors and elevates cytosolic calcium. CFTR-dependent secretion (C-sweat) was stimulated with a β-adrenergic cocktail that elevates cytosolic cAMP while blocking muscarinic receptors. A C-sweat/M-sweat ratio was determined on a gland-by-gland basis to compensate for differences unrelated to CFTR function, such as gland size. The average ratio provides an approximately linear readout of CFTR function: the heterozygote ratio is ∼0.5 the control ratio and for CF subjects the ratio is zero. During assay development, we measured C/M ratios in 6 healthy controls, 4 CF heterozygotes, 18 CF subjects and 4 subjects with ‘CFTR-related’ conditions. The assay discriminated all groups clearly. It also revealed consistent differences in the C/M ratio among subjects within groups. We hypothesize that these differences reflect, at least in part, levels of CFTR expression, which are known to vary widely. When C-sweat rates become very low the C/M ratio also tended to decrease; we hypothesize that this nonlinearity reflects ductal fluid absorption. We also discovered that M-sweating potentiates the subsequent C-sweat response. We then used potentiation as a surrogate for drugs that can increase CFTR-dependent secretion. This bioassay provides an additional method for assessing CFTR function in vivo, and is well suited for within-subject tests of systemic, CFTR-directed therapeutics. PMID:24204751

  7. Prolonged and localized sweat stimulation by iontophoretic delivery of the slowly-metabolized cholinergic agent carbachol.

    PubMed

    Simmers, Phillip; Li, S Kevin; Kasting, Gerald; Heikenfeld, Jason

    2018-01-01

    Continuous non-invasive sampling and sensing of multiple classes of analytes could revolutionize medical diagnostics and wearable technologies, but also remains highly elusive because of the many confounding factors for candidate biofluids such as interstitial fluid, tears, saliva, and sweat. Eccrine sweat biosensing has seen a recent surge in demonstrations of wearable sampling and sensing devices. However, for subjects at rest, access to eccrine sweat is highly limited and unpredictable compared to saliva and tears. Reported here is a prolonged and localized sweat stimulation by iontophoretic delivery of the slowly-metabolized nicotinic cholinergic agonist carbachol. Presented here are detailed measurements of natural baseline sweat rates across multiple days, confirming a clear need for localized sweat stimulation. Iontophoresis was performed with either carbachol or pilocarpine in order to stimulate sweat in subjects at rest. Furthermore, improved methods of quantifying sweat generation rates (nL/min/gland) are demonstrated. In-vivo testing reveals that carbachol stimulation can surpass a major goal of 24-h sweat access, in some cases providing more than an order of magnitude longer duration than stimulation with commonly-used pilocarpine. Also demonstrated is reduction of the traditional iontophoretic dosage for sweat stimulation (<5.25-42mC/cm 2 ). This increases the viability of repeated dosing as demonstrated herein, and for carbachol is as much as 100-1000X less than used for other applications. This work is not only significant for wearable sweat biosensing technology, but could also have broader impact for those studying topical skin products, antiperspirants, textiles and medical adhesives, nerve disorders, the effects of perspiration on skin-health, skin related diseases such as idiopathic pure sudomotor failure and hyperhidrosis, and other skin- and perspiration-related applications. Copyright © 2017 Japanese Society for Investigative Dermatology. Published by Elsevier B.V. All rights reserved.

  8. Comparison of workers’ perceptions toward work climate and health symptoms between ceramic and iron foundry workers

    PubMed Central

    Majumder, Joydeep; Bagepally, Bhavani S.; Shah, Priyanka; Kotadiya, Sanjay; Yadav, Suresh; Naha, Nibedita

    2016-01-01

    Background: Workers exposed to heavy manual material handling (MMH) in a hot working environment succumb to severe physical stress and psychological stress. Aims: (1) Recognize the heat load at workplaces of ceramic industry and iron industry, and (2) comparatively examine the characteristics of self-reported physiological responses and heat-health perception among these workers. Settings and Design: Cross-sectional prospective study. Materials and Methods: Workplace microclimate in the ceramic industry and iron industry was monitored. An ergonomic checklist and a questionnaire was used to record self-reported workers’ perceptions toward heat stress at workplace (ceramic workers N = 321, iron foundry workers N = 253). The prevalence rates of subjective symptoms among workers of both the industries were compared. Statistical Analysis: Chi-square test was used to examine the association between stressors and health complaints at a significance level set at P < 0.05. Results: Iron foundries recorded higher mean ambient temperature (43.4 ± 3.7°C) and wet-bulb globe temperature (WGBT) index (31.5 ± 0.7°C) as compared to ceramic industries (39.9 ± 3.3°C and 28 ± 1.5°C, respectively). Heavy sweating, elevated body temperature, sleeplessness, excessive thirst, muscular discomforts, and fatigue were prime symptoms recorded among workers of both industries. Skin-related disorders (red face, dry skin, bumps, itching) were significantly higher among iron foundry workers, whereas sleeplessness, high blood pressure, heavy sweating, kidney stone, decreased urination, muscular discomforts, and fatigue were significantly more among ceramic workers. Young workers reported more sweating and fatigue than older workers. Conclusions: A hot work climate and heavy manual labor designate ceramic and iron industries as arduous. Direct contact with hot surface and continuous MMH in tandem with the mechanical pace of production process makes work in ceramic industries more difficult than iron foundries. PMID:27390480

  9. Whole-body heat loss during exercise in the heat is not impaired in type 1 diabetes.

    PubMed

    Stapleton, Jill M; Yardley, Jane E; Boulay, Pierre; Sigal, Ronald J; Kenny, Glen P

    2013-09-01

    The objective of this study is to determine whether individuals with type 1 diabetes exhibit impairments in local and whole-body heat loss responses that could affect core temperature regulation during exercise in the heat compared with matched, nondiabetic individuals. Twelve otherwise healthy individuals with type 1 diabetes (HbA1c = 7.7% ± 0.3%) and 12 controls matched for age, sex, body surface area, and physical fitness cycled continuously for 60 min at a set rate of metabolic heat production (approximately 400 W) in a whole-body direct calorimeter (35°C and 20% relative humidity). Local sweat rate (ventilated capsule) was measured on the back and skin blood flow (laser Doppler velocimetry) on the forearm. Core (rectal and esophageal) and mean skin temperatures and heart rate were measured continuously. Whole-body heat exchange and change in body heat content were measured using simultaneous direct whole-body and indirect calorimetry. The change (mean ± SE) in body heat content was similar between groups during exercise (diabetes, 409 ± 27 kJ; control, 386 ± 33 kJ; P = 0.584) and recovery (diabetes, -115 ± 16 kJ; control, -93 ± 24 kJ; P = 0.457). Local heat loss responses of sweating (P = 0.783) and skin blood flow (P = 0.078) as well as rectal temperature (diabetes, 37.87°C ± 0.10°C; control, 37.85°C; ± 0.13°C; P = 0.977) and heart rate (diabetes, 130 ± 9 beats·min, vs control, 126 ± 8 beats·min, P = 0.326) were comparable at the end of the exercise period. During light-to-moderate-intensity exercise performed under conditions permitting full sweat evaporation, otherwise healthy type 1 diabetic individuals did not show impaired heat loss responses during heat exposure when compared with matched individuals without diabetes.

  10. Exercise thermoregulation after 6 h of chair rest, 6 degrees head-down bed-rest, and water immersion deconditioning in men

    NASA Technical Reports Server (NTRS)

    Greenleaf, J. E.; Hutchinson, T.; Shaffer-Bailey, M.; Looft-Wilson, R.

    1996-01-01

    The purpose was to investigate the mechanism for the excessive exercise hyperthermia following deconditioning (reduction of physical fitness). Rectal (Tre) and mean skin (Tsk) temperatures and thermoregulatory responses were measured in six men [mean (SD) age, 32 (6) years; mass, 78.26 (5.80) kg; surface area, 1.95 (0.11) m2; maximum oxygen uptake (VO2max), 48 (6) ml.min-1.kg-1; whilst supine in air at dry bulb temperature 23.2 (0.6) degree C, relative humidity 31.1 (11.1)% and air speed 5.6 (0.1) m.min-1] during 70 min of leg cycle exercise [51 (4)% VO2max] in ambulatory control (AC), or following 6 h of chair rest (CR), 6 degree head-down bed rest (BR), and 20 degree (WI20) and 80 degree (WI80) foot-down water immersion [water temperature, 35.0 (0.1) degree C]. Compared with the AC exercise delta Tre [mean (SD) 0.77 (0.13) degree C (*P < 0.05), after WI80 0.96 (0.13) degree C*, and after WI20 1.03 (0.09) degree C*. All Tsk responded similarly to exercise: they decreased (NS) by 0.5-0.7 degree C in minutes 4-8 and equilibrated at +0.1 to +0.5 degree C at 60-70. Skin heat conductance was not different among the five conditions (range = 147-159 kJ.m-2.h-1.degree C-1). Results from an intercorrelation matrix suggested that total body sweat rate was more closely related to Tre at 70 min (Tre70) than limb sweat rate or blood flow. Only 36% of the variability in Tre70 could be accounted for by total sweating, and less than 10% from total body dehydration. It would appear that multiple factors are involved which may include change in sensitivity of thermo- and osmoreceptors.

  11. Human local and total heat losses in different temperature.

    PubMed

    Wang, Lijuan; Yin, Hui; Di, Yuhui; Liu, Yanfeng; Liu, Jiaping

    2016-04-01

    This study investigates the effects of operative temperature on the local and total heat losses, and the relationship between the heat loss and thermal sensation. 10 local parts of head, neck, chest, abdomen, upper arm, forearm, hand, thigh, leg and foot are selected. In all these parts, convection, radiation, evaporation, respiration, conduction and diffusion heat losses are analyzed when operative temperature is 23, 28, 33 and 37 °C. The local heat losses show that the radiation and convection heat losses are mainly affected by the area of local body, and the heat loss of the thigh is the most in the ten parts. The evaporation heat loss is mainly affected by the distribution of sweat gland, and the heat loss of the chest is the most. The total heat loss of the local body shows that in low temperature, the thigh, leg and chest have much heat loss, while in high temperature, the chest, abdomen, thigh and head have great heat loss, which are useful for clothing design. The heat losses of the whole body show that as the operative temperature increases, the radiation and convection heat losses decrease, the heat losses of conduction, respiration, and diffusion are almost constant, and the evaporation heat loss increases. By comparison, the heat loss ratios of the radiation, convection and sweat evaporation, are in agreement with the previous researches. At last, the formula about the heat loss ratio of convection and radiation is derived. It's useful for thermal comfort evaluation and HVAC (heating, ventilation and air conditioning) design. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Pre-exercise ingestion of pickle juice, hypertonic saline, or water and aerobic performance and thermoregulation.

    PubMed

    Peikert, Jarett; Miller, Kevin C; Albrecht, Jay; Tucker, Jared; Deal, James

    2014-01-01

    Ingesting high-sodium drinks pre-exercise can improve thermoregulation and performance. Athletic trainers (19%) give athletes pickle juice (PJ) prophylactically for cramping. No data exist on whether this practice affects aerobic performance or thermoregulation. To determine if drinking 2 mL/kg body mass of PJ, hypertonic saline, or deionized water (DIW) pre-exercise affects aerobic performance or thermoregulation. Crossover study. Controlled laboratory study. Nine euhydrated men (age = 22 ± 3 years, height = 184.0 ± 8.2 cm, mass = 82.6 ± 16.0 kg) completed testing. Participants rested for 65 minutes. During this period, they ingested 2 mL/kg of PJ, hypertonic saline, or DIW. Next, they drank 5 mL/kg of DIW. Blood was collected before and after ingestion of all fluids. Participants were weighed and ran in the heat (temperature = 38.3°C ± 1°C, relative humidity = 21.1% ± 4.7%) at increasing increments of maximal heart rate (50%, 60%, 70%, 80%, 90%, 95%) until exhaustion or until rectal temperature exceeded 39.5°C. Participants were weighed postexercise so we could calculate sweat volume. Time to exhaustion, rectal temperature, changes in plasma volume, and sweat volume. Time to exhaustion did not differ among drinks (PJ = 77.4 ± 5.9 minutes, hypertonic saline = 77.4 ± 4.0 minutes, DIW = 75.7 ± 3.2 minutes; F2,16 = 1.1, P = .40). Core temperature of participants was similar among drinks (PJ = 38.7°C ± 0.3°C, hypertonic saline = 38.7°C ± 0.4°C, DIW = 38.8°C ± 0.4°C; P = .74) but increased from pre-exercise (36.7°C ± 0.2°C) to postexercise (38.7°C ± 0.4°C) (P < .05). No differences were observed for changes in plasma volume or sweat volume among drinks (P > .05). Ingesting small amounts of PJ or hypertonic saline with water did not affect performance or select thermoregulatory measures. Drinking larger volumes of PJ and water may be more effective at expanding the extracellular space.

  13. Age-Related Changes in Children's Hedonic Response to Male Body Odor.

    ERIC Educational Resources Information Center

    Stevenson, Richard J.; Repacholi, Betty M.

    2003-01-01

    Examined children's and adolescents' ability to identify male sweat and other odors and their rating of odors for liking. Found that only female adolescents could identify and disliked male sweat. When cued about odor identity, both male and female adolescents disliked male sweat more than children. Concluded that dislike for male sweat odor may…

  14. General Procedure for Protective Cooling and Equipment Evaluations Relative to Heat and Cold Stress

    DTIC Science & Technology

    2008-09-01

    climatic chamber housing the manikin. The most widely accepted test procedures for the operation of a TM are published by the American Society for...describes measurement of the clo value of a complete clothing ensemble. It requires a TM surface temperature of 35ºC and a climatic chamber controlled...Clothing Using a Sweating Manikin” (1) measures the im of a complete clothing ensemble. It requires a TM surface temperature of 35ºC and a climatic

  15. Adjustment and Validation of the Mathematical Prediction Model for Sweat Rate, Heart Rate and Body Temperature under Outdoor Conditions

    DTIC Science & Technology

    1986-11-01

    Predicting rectal temperature response to work environment and clothing. J. Pppl . PhysioL. 32: 812-822, 1972. 3. Givoni B., Goldman RF: Predicting...heart rote response to work, environment and clothing. J. PppL . PhysioL. 34: 201-204, 1973. 4. Givoni B., Goldman RF: Predicting effects of heat...expenditure with loads while standing or walking very slowly. J. Pppl . Physlol. 43: 477-581, 1877. G. Shapiro Y., Pandolf KB., Breckenridge JR., Goldman RF

  16. Brain stem representation of thermal and psychogenic sweating in humans.

    PubMed

    Farrell, Michael J; Trevaks, David; Taylor, Nigel A S; McAllen, Robin M

    2013-05-15

    Functional MRI was used to identify regions in the human brain stem activated during thermal and psychogenic sweating. Two groups of healthy participants aged 34.4 ± 10.2 and 35.3 ± 11.8 years (both groups comprising 1 woman and 10 men) were either heated by a water-perfused tube suit or subjected to a Stroop test, while they lay supine with their head in a 3-T MRI scanner. Sweating events were recorded as electrodermal responses (increases in AC conductance) from the palmar surfaces of fingers. Each experimental session consisted of two 7.9-min runs, during which a mean of 7.3 ± 2.1 and 10.2 ± 2.5 irregular sweating events occurred during psychogenic (Stroop test) and thermal sweating, respectively. The electrodermal waveform was used as the regressor in each subject and run to identify brain stem clusters with significantly correlated blood oxygen level-dependent signals in the group mean data. Clusters of significant activation were found with both psychogenic and thermal sweating, but a voxelwise comparison revealed no brain stem cluster whose signal differed significantly between the two conditions. Bilaterally symmetric regions that were activated by both psychogenic and thermal sweating were identified in the rostral lateral midbrain and in the rostral lateral medulla. The latter site, between the facial nuclei and pyramidal tracts, corresponds to a neuron group found to drive sweating in animals. These studies have identified the brain stem regions that are activated with sweating in humans and indicate that common descending pathways may mediate both thermal and psychogenic sweating.

  17. Matrigel basement membrane matrix induces eccrine sweat gland cells to reconstitute sweat gland-like structures in nude mice.

    PubMed

    Li, Haihong; Chen, Lu; Zeng, Shaopeng; Li, Xuexue; Zhang, Xiang; Lin, Changmin; Zhang, Mingjun; Xie, Sitian; He, Yunpu; Shu, Shenyou; Yang, Lvjun; Tang, Shijie; Fu, Xiaobing

    2015-03-01

    Severe burn results in irreversible damage to eccrine sweat glands, for which no effective treatment is available. Interaction between the extracellular matrix and epithelial cells is critical for proper three-dimensional organization and function of the epithelium. Matrigel-embedded eccrine sweat gland cells were subcutaneously implanted into the inguinal regions of nude mice. Two weeks later, the Matrigel plugs were removed and evaluated for series of detection items. Sweat gland cells developed into sweat gland-like structures in the Matrigel plugs based on: (1) de novo formation of tubular-like structures with one or more hollow lumens, (2) expression of epithelial and sweat gland markers (pancytokeratin, CK5/7/14/19, α-SMA and CEA), (3) basement membrane formation, (4) myoepithelial cells presenting in and encompassing the tubular-like structures, (5) cellular polarization, evident by the expression of tight junction proteins (claudin-1 and ZO-2), anchoring junctions (desmoglein-1 and -2 and E-cadherin) and CEA in the luminal membrane, (6) expression of proteins related to sweat secretion and absorption (Na(+)-K(+)-ATPase α/β, Na(+)-K(+)-2Cl-cotranspoter 1, Na(+)/H(+) exchanger 1, aquaporin-5, epithelial sodium channel, cystic fibrosis transmembrane conductance regulator, potassium channel and vacuolar-type H+-ATPase), and (7) about 20% of the tubular-like structures are de novo coils and 80% are de novo ducts. This study provides not only an excellent model to study eccrine sweat gland development, cytodifferentiation and reconstitution, but also an in vivo model for regeneration of eccrine sweat glands. Copyright © 2015 Elsevier Inc. All rights reserved.

  18. Autonomous sweat extraction and analysis applied to cystic fibrosis and glucose monitoring using a fully integrated wearable platform.

    PubMed

    Emaminejad, Sam; Gao, Wei; Wu, Eric; Davies, Zoe A; Yin Yin Nyein, Hnin; Challa, Samyuktha; Ryan, Sean P; Fahad, Hossain M; Chen, Kevin; Shahpar, Ziba; Talebi, Salmonn; Milla, Carlos; Javey, Ali; Davis, Ronald W

    2017-05-02

    Perspiration-based wearable biosensors facilitate continuous monitoring of individuals' health states with real-time and molecular-level insight. The inherent inaccessibility of sweat in sedentary individuals in large volume (≥10 µL) for on-demand and in situ analysis has limited our ability to capitalize on this noninvasive and rich source of information. A wearable and miniaturized iontophoresis interface is an excellent solution to overcome this barrier. The iontophoresis process involves delivery of stimulating agonists to the sweat glands with the aid of an electrical current. The challenge remains in devising an iontophoresis interface that can extract sufficient amount of sweat for robust sensing, without electrode corrosion and burning/causing discomfort in subjects. Here, we overcame this challenge through realizing an electrochemically enhanced iontophoresis interface, integrated in a wearable sweat analysis platform. This interface can be programmed to induce sweat with various secretion profiles for real-time analysis, a capability which can be exploited to advance our knowledge of the sweat gland physiology and the secretion process. To demonstrate the clinical value of our platform, human subject studies were performed in the context of the cystic fibrosis diagnosis and preliminary investigation of the blood/sweat glucose correlation. With our platform, we detected the elevated sweat electrolyte content of cystic fibrosis patients compared with that of healthy control subjects. Furthermore, our results indicate that oral glucose consumption in the fasting state is followed by increased glucose levels in both sweat and blood. Our solution opens the possibility for a broad range of noninvasive diagnostic and general population health monitoring applications.

  19. Cutaneous microdialysis as a novel means of continuously stimulating eccrine sweat glands in vivo.

    PubMed

    Morgan, Caroline J; Friedmann, Peter S; Church, Martin K; Clough, Geraldine F

    2006-06-01

    Previous studies of the pharmacological regulation of sweat gland function in humans have administered agonists or antagonists systemically, by local intradermal injection or by iontophoresis. This has not allowed prolonged or steady-state activation of sweat glands to be examined. In this study, we used the technique of dermal microdialysis to administer pharmacological agents singly and in combination for up to 5 hours. Muscarinic stimulation with pilocarpine nitrate (50 mug ml(-1) to 1.66 mg ml(-1)) produced a sigmoid dose response curve, with maximal sweating (measured as transepidermal water loss) (mean 70 g m(-2) hour(-1)) after 15 minutes. This was sustained at steady-state levels (55 g m(-2) hour(-1)) until perfusion stopped. Perfusion with atropine (0.003 mg ml(-1)) reduced sweating below baseline and blocked pilocarpine-induced sweating completely. Noradrenaline (0.005 mg ml(-1)) induced much lower sweat rates than pilocarpine (56.8+/-1.62 g m(-2) hour(-1) vs 8.2+/-1.2 g m(-2) hour(-1), respectively, P<0.001) and this was unaffected by co-administration of atropine. This method has made it possible to show that sweat glands are capable of sustaining near maximal activity for at least 5 hours. The method has future application in investigation of conditions with disordered sweat gland activity.

  20. Proteomic profiling of eccrine sweat reveals its potential as a diagnostic biofluid for active tuberculosis.

    PubMed

    Adewole, Olanisun Olufemi; Erhabor, Greg Efosa; Adewole, Temitayo Oluwatoyin; Ojo, Abiodun Oluwasesan; Oshokoya, Harriet; Wolfe, Lisa M; Prenni, Jessica E

    2016-05-01

    Excessive sweating is a common symptom of the disease and an unexplored biofluid for TB diagnosis; we conducted a proof-of-concept study to identify potential diagnostic biomarkers of active TB in eccrine sweat. We performed a global proteomic profile of eccrine sweat sampled from patients with active pulmonary TB, other lung diseases (non-TB disease), and healthy controls. A comparison of proteomics between Active-TB, Non-TB, and Healthy Controls was done in search for potential biomarkers of active TB. Sweat specimens were pooled from 32 active TB patients, 27 patients with non-TB diseases, and 24 apparently healthy controls, all were negative for HIV. Over 100 unique proteins were identified in the eccrine sweat of all three groups. Twenty-six proteins were exclusively detected in the sweat of patients with active TB while the remaining detected proteins overlapped between three groups. Gene ontology evaluation indicated that the proteins detected uniquely in sweat of active TB patients were involved in immune response and auxiliary protein transport. Gene products for cellular components (e.g. ribosomes) were detected only in active TB patients. Data are available via ProteomeXchange with identifier PXD003224. Proteomics of sweat from active TB patients is a viable approach for biomarker identification, which could be used to develop a nonsputum-based test for detection of active TB. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Development of a method for enhancing metabolomics coverage of human sweat by gas chromatography-mass spectrometry in high resolution mode.

    PubMed

    Delgado-Povedano, M M; Calderón-Santiago, M; Priego-Capote, F; Luque de Castro, M D

    2016-01-28

    Sweat has recently gained popularity as clinical sample in metabolomics analysis as it is a non-invasive biofluid the composition of which could be modified by certain pathologies, as is the case with cystic fibrosis that increases chloride levels in sweat. However, the whole composition of sweat is still unknown and there is a lack of analytical strategies for sweat analysis. The aim of the present study was to develop and validate a method for metabolomic analysis of human sweat by gas chromatography-time of flight/mass spectrometry (GC-TOF/MS) in high resolution mode. Thus, different sample preparation strategies were compared to check their effect on the profile of sweat metabolites. Sixty-six compounds were tentatively identified by the obtained MS information. Amino acids, dicarboxylic acids and other interesting metabolites such as myo-inositol and urocanic acid were identified. Among the tested protocols, methyoxiamination plus silylation after deproteinization was the most suited option to obtain a representative snapshot of sweat metabolome. The intra-day repeatability of the method ranged from 0.60 to 16.99% and the inter-day repeatability from 2.75 to 31.25%. As most of the identified metabolites are involved in key biochemical pathways, this study opens new possibilities to the use of sweat as a source of metabolite biomarkers of specific disorders. Copyright © 2015 Elsevier B.V. All rights reserved.

  2. Flexible nanoporous tunable electrical double layer biosensors for sweat diagnostics.

    PubMed

    Munje, Rujuta D; Muthukumar, Sriram; Panneer Selvam, Anjan; Prasad, Shalini

    2015-09-30

    An ultra-sensitive and highly specific electrical double layer (EDL) modulated biosensor, using nanoporous flexible substrates for wearable diagnostics is demonstrated with the detection of the stress biomarker cortisol in synthetic and human sweat. Zinc oxide thin film was used as active region in contact with the liquid i.e. synthetic and human sweat containing the biomolecules. Cortisol detection in sweat was accomplished by measuring and quantifying impedance changes due to modulation of the double layer capacitance within the electrical double layer through the application of a low orthogonally directed alternating current (AC) electric field. The EDL formed at the liquid-semiconductor interface was amplified in the presence of the nanoporous flexible substrate allowing for measuring the changes in the alternating current impedance signal due to the antibody-hormone interactions at diagnostically relevant concentrations. High sensitivity of detection of 1 pg/mL or 2.75 pmol cortisol in synthetic sweat and 1 ng/mL in human sweat is demonstrated with these novel biosensors. Specificity in synthetic sweat was demonstrated using a cytokine IL-1β. Cortisol detection in human sweat was demonstrated over a concentration range from 10-200 ng/mL.

  3. Flexible nanoporous tunable electrical double layer biosensors for sweat diagnostics

    NASA Astrophysics Data System (ADS)

    Munje, Rujuta D.; Muthukumar, Sriram; Panneer Selvam, Anjan; Prasad, Shalini

    2015-09-01

    An ultra-sensitive and highly specific electrical double layer (EDL) modulated biosensor, using nanoporous flexible substrates for wearable diagnostics is demonstrated with the detection of the stress biomarker cortisol in synthetic and human sweat. Zinc oxide thin film was used as active region in contact with the liquid i.e. synthetic and human sweat containing the biomolecules. Cortisol detection in sweat was accomplished by measuring and quantifying impedance changes due to modulation of the double layer capacitance within the electrical double layer through the application of a low orthogonally directed alternating current (AC) electric field. The EDL formed at the liquid-semiconductor interface was amplified in the presence of the nanoporous flexible substrate allowing for measuring the changes in the alternating current impedance signal due to the antibody-hormone interactions at diagnostically relevant concentrations. High sensitivity of detection of 1 pg/mL or 2.75 pmol cortisol in synthetic sweat and 1 ng/mL in human sweat is demonstrated with these novel biosensors. Specificity in synthetic sweat was demonstrated using a cytokine IL-1β. Cortisol detection in human sweat was demonstrated over a concentration range from 10-200 ng/mL.

  4. Voluntary fluid intake and core temperature responses in adolescent tennis players: sports beverage versus water.

    PubMed

    Bergeron, M F; Waller, J L; Marinik, E L

    2006-05-01

    To examine differences in ad libitum fluid intake, comparing a 6% carbohydrate/electrolyte drink (CHO-E) and water, and associated differences in core temperature and other selected physiological and perceptual responses in adolescent athletes during tennis training in the heat. Fourteen healthy, fit, young tennis players (nine male; five female; mean (SD) age 15.1 (1.4) years; weight 60.6 (8.3) kg; height 172.8 (8.6) cm) completed two 120 minute tennis specific training sessions on separate days (randomised, crossover design) in a warm environment (wet bulb globe temperature: CHO-E, 79.3 (2.6) degrees F; water, 79.9 (2.2) degrees F; p>0.05). There were no significant differences (p>0.05) between the trials with respect to fluid intake, urine volume, fluid retention, sweat loss, perceived exertion, thirst, or gastrointestinal discomfort. However, there was a difference (p<0.05) in the percentage body weight change after training (CHO-E, -0.5 (0.7)%; water, -0.9 (0.6)%). Urine specific gravity before training (CHO-E, 1.024 (0.006); water, 1.025 (0.005)) did not correlate significantly (p>0.05) with any of these measurements or with core body temperature. In examining the main effect for trial, the CHO-E trial showed a significantly lower (p<0.001) mean body temperature (irrespective of measurement time) than the water trial. However, the mean body temperature in each trial was not associated (p>0.05) with fluid intake, fluid retention, sweat loss, or percentage body weight change. Ad libitum consumption of a CHO-E drink may be more effective than water in minimising fluid deficits and mean core temperature responses during tennis and other similar training in adolescent athletes.

  5. Mild Dehydration and Cycling Performance During 5-Kilometer Hill Climbing

    PubMed Central

    Bardis, Costas N.; Kavouras, Stavros A.; Arnaoutis, Giannis; Panagiotakos, Demosthenes B.; Sidossis, Labros S.

    2013-01-01

    Context: Hydration has been shown to be an important factor in performance; however, the effects of mild dehydration during intense cycling are not clear. Objective: To determine the influence of mild dehydration on cycling performance during an outdoor climbing trial in the heat (ambient temperature = 29.0°C ± 2.2°C). Design: Crossover study. Setting: Outdoor. Patients or Other Participants: Ten well-trained, male endurance cyclists (age = 28 ± 5 years, height = 182 ± 0.4 cm, mass = 73 ± 4 kg, maximal oxygen uptake = 56 ± 9 mL·min−1·kg−1, body fat = 23% ± 2%, maximal power = 354 ± 48 W). Intervention(s): Participants completed 1 hour of steady-state cycling with or without drinking to achieve the desired pre-exercise hydration level before 5-km hill-climbing cycling. Participants started the 5-km ride either euhydrated (EUH) or dehydrated by −1% of body mass (DEH). Main Outcome Measure(s): Performance time, core temperature, sweat rate, sweat sensitivity, and rating of perceived exertion (RPE). Results: Participants completed the 5-km ride 5.8% faster in the EUH (16.6 ± 2.3 minutes) than DEH (17.6 ± 2.9 minutes) trial (t1 = 10.221, P = .001). Postexercise body mass was −1.4% ± 0.3% for the EUH trial and −2.2% ± 0.2% for the DEH trial (t1 = 191.384, P < .001). Core temperature after the climb was greater during the DEH (39.2°C ± 0.3°C) than EUH (38.8°C ± 0.2°C) trial (t1 = 8.04, P = .005). Sweat rate was lower during the DEH (0.44 ± 0.16 mg·m−2·s−1) than EUH (0.51 ± 0.16 mg·m−2·s−1) trial (t8 = 2.703, P = .03). Sweat sensitivity was lower during the DEH (72.6 ± 32 g·°C−1·min−1) than EUH (102.6 ± 54.2 g·°C−1·min−1) trial (t8 = 3.072, P = .02). Lastly, RPE after the exercise performance test was higher for the DEH (19.0 ± 1.0) than EUH (17.0 ± 1.0) participants (t9 = −3.36, P = .008). Conclusions: We found mild dehydration decreased cycling performance during a 5-km outdoor hill course, probably due to greater heat strain and greater perceived intensity. PMID:23952038

  6. Attitudes about Advances in Sweat Patch Testing in Drug Courts: Insights from a Case Study in Southern California

    ERIC Educational Resources Information Center

    Polzer, Katherine

    2010-01-01

    Drug courts are reinventing the drug testing framework by experimenting with new methods, including use of the sweat patch. The sweat patch is a band-aid like strip used to monitor drug court participants. The validity and reliability of the sweat patch as an effective testing method was examined, as well as the effectiveness, meaning how likely…

  7. Prevalence and predictors of night sweats, day sweats, and hot flashes in older primary care patients: an OKPRN study.

    PubMed

    Mold, James W; Roberts, Michelle; Aboshady, Hesham M

    2004-01-01

    We wanted to estimate the prevalence of night sweats, day sweats, and hot flashes in older primary care patients and identify associated factors. We undertook a cross-sectional study of patients older than 64 years recruited from the practices of 23 family physicians. Variables included sociodemographic information, health habits, chronic medical problems, symptoms, quality of life, and the degree to which patients were bothered by night sweats, daytime sweating, and hot flashes. Among the 795 patients, 10% reported being bothered by night sweats, 9% by day sweats, and 8% by hot flashes. Eighteen percent reported at least 1 of these symptoms. The 3 symptoms were strongly correlated. Factors associated with night sweats in the multivariate models were age (odds ratio [OR] 0.94/y; 95% confidence interval [CI], 0.89-0.98), fever (OR 12.60; 95% CI, 6.58-24.14), muscle cramps (OR 2.84; 95% CI, 1.53-5.24), numbness of hands and feet (OR 3.34; 95% CI, 1.92-5.81), impaired vision (OR 2.45; 95% CI, 1.41-4.27), and hearing loss (OR 1.84; 95% CI, 1.03-3.27). Day sweats were associated with fever (OR 4.10; 95% CI, 2.14-7.87), restless legs (OR 3.22; 95% CI, 1.76-5.89), lightheadedness (OR 2.24; 95% CI, 1.30-3.88), and diabetes (OR 2.19; 95% CI, 1.22-3.92). Hot flashes were associated with nonwhite race (OR 3.10; 95% CI, 1.60-5.98), fever (OR 3.98; 95% CI, 1.97-8.04), bone pain (OR 2.31; CI 95%: 1.30-4.08), impaired vision (OR 2.12; 95% CI, 1.19-3.79), and nervous spells (OR 1.87; 95% CI, 1.01-3.46). All 3 symptoms were associated with reduced quality of life. Many older patients are bothered by night sweats, day sweats, and hot flashes. Though these symptoms are similar and related, they have somewhat different associations with other variables. Clinical evaluation should include questions about febrile illnesses, sensory deficits, anxiety, depression, pain, muscle cramps, and restless legs syndrome.

  8. iNOS-dependent sweating and eNOS-dependent cutaneous vasodilation are evident in younger adults, but are diminished in older adults exercising in the heat

    PubMed Central

    Fujii, Naoto; Meade, Robert D.; Alexander, Lacy M.; Akbari, Pegah; Foudil-bey, Imane; Louie, Jeffrey C.; Boulay, Pierre

    2015-01-01

    Nitric oxide synthase (NOS) contributes to sweating and cutaneous vasodilation during exercise in younger adults. We hypothesized that endothelial NOS (eNOS) and neuronal NOS (nNOS) mediate NOS-dependent sweating, whereas eNOS induces NOS-dependent cutaneous vasodilation in younger adults exercising in the heat. Further, aging may upregulate inducible NOS (iNOS), which may attenuate sweating and cutaneous vasodilator responses. We hypothesized that iNOS inhibition would augment sweating and cutaneous vasodilation in exercising older adults. Physically active younger (n = 12, 23 ± 4 yr) and older (n = 12, 60 ± 6 yr) adults performed two 30-min bouts of cycling at a fixed rate of metabolic heat production (400 W) in the heat (35°C). Sweat rate and cutaneous vascular conductance (CVC) were evaluated at four intradermal microdialysis sites with: 1) lactated Ringer (control), 2) nNOS inhibitor (nNOS-I, NPLA), 3) iNOS inhibitor (iNOS-I, 1400W), or 4) eNOS inhibitor (eNOS-I, LNAA). In younger adults during both exercise bouts, all inhibitors decreased sweating relative to control, albeit a lower sweat rate was observed at iNOS-I compared with eNOS-I and nNOS-I sites (all P < 0.05). CVC at the eNOS-I site was lower than control in younger adults throughout the intermittent exercise protocol (all P < 0.05). In older adults, there were no differences between control and iNOS-I sites for sweating and CVC during both exercise bouts (all P > 0.05). We show that iNOS and eNOS are the main contributors to NOS-dependent sweating and cutaneous vasodilation, respectively, in physically active younger adults exercising in the heat, and that iNOS inhibition does not alter sweating or cutaneous vasodilation in exercising physically active older adults. PMID:26586908

  9. iNOS-dependent sweating and eNOS-dependent cutaneous vasodilation are evident in younger adults, but are diminished in older adults exercising in the heat.

    PubMed

    Fujii, Naoto; Meade, Robert D; Alexander, Lacy M; Akbari, Pegah; Foudil-Bey, Imane; Louie, Jeffrey C; Boulay, Pierre; Kenny, Glen P

    2016-02-01

    Nitric oxide synthase (NOS) contributes to sweating and cutaneous vasodilation during exercise in younger adults. We hypothesized that endothelial NOS (eNOS) and neuronal NOS (nNOS) mediate NOS-dependent sweating, whereas eNOS induces NOS-dependent cutaneous vasodilation in younger adults exercising in the heat. Further, aging may upregulate inducible NOS (iNOS), which may attenuate sweating and cutaneous vasodilator responses. We hypothesized that iNOS inhibition would augment sweating and cutaneous vasodilation in exercising older adults. Physically active younger (n = 12, 23 ± 4 yr) and older (n = 12, 60 ± 6 yr) adults performed two 30-min bouts of cycling at a fixed rate of metabolic heat production (400 W) in the heat (35°C). Sweat rate and cutaneous vascular conductance (CVC) were evaluated at four intradermal microdialysis sites with: 1) lactated Ringer (control), 2) nNOS inhibitor (nNOS-I, NPLA), 3) iNOS inhibitor (iNOS-I, 1400W), or 4) eNOS inhibitor (eNOS-I, LNAA). In younger adults during both exercise bouts, all inhibitors decreased sweating relative to control, albeit a lower sweat rate was observed at iNOS-I compared with eNOS-I and nNOS-I sites (all P < 0.05). CVC at the eNOS-I site was lower than control in younger adults throughout the intermittent exercise protocol (all P < 0.05). In older adults, there were no differences between control and iNOS-I sites for sweating and CVC during both exercise bouts (all P > 0.05). We show that iNOS and eNOS are the main contributors to NOS-dependent sweating and cutaneous vasodilation, respectively, in physically active younger adults exercising in the heat, and that iNOS inhibition does not alter sweating or cutaneous vasodilation in exercising physically active older adults. Copyright © 2016 the American Physiological Society.

  10. Sweat collection capsule

    NASA Technical Reports Server (NTRS)

    Delaplaine, R. W.; Greenleaf, J. E.

    1979-01-01

    Capsule, with filter paper insert, is used to collect sweat for rate monitoring, chromatographic analysis, or active sweat gland location within specified area. Construction of capsule allows change of inserts while device remains strapped in place.

  11. Whole genome detection of signature of positive selection in African cattle reveals selection for thermotolerance.

    PubMed

    Taye, Mengistie; Lee, Wonseok; Caetano-Anolles, Kelsey; Dessie, Tadelle; Hanotte, Olivier; Mwai, Okeyo Ally; Kemp, Stephen; Cho, Seoae; Oh, Sung Jong; Lee, Hak-Kyo; Kim, Heebal

    2017-12-01

    As African indigenous cattle evolved in a hot tropical climate, they have developed an inherent thermotolerance; survival mechanisms include a light-colored and shiny coat, increased sweating, and cellular and molecular mechanisms to cope with high environmental temperature. Here, we report the positive selection signature of genes in African cattle breeds which contribute for their heat tolerance mechanisms. We compared the genomes of five indigenous African cattle breeds with the genomes of four commercial cattle breeds using cross-population composite likelihood ratio (XP-CLR) and cross-population extended haplotype homozygosity (XP-EHH) statistical methods. We identified 296 (XP-EHH) and 327 (XP-CLR) positively selected genes. Gene ontology analysis resulted in 41 biological process terms and six Kyoto Encyclopedia of Genes and Genomes pathways. Several genes and pathways were found to be involved in oxidative stress response, osmotic stress response, heat shock response, hair and skin properties, sweat gland development and sweating, feed intake and metabolism, and reproduction functions. The genes and pathways identified directly or indirectly contribute to the superior heat tolerance mechanisms in African cattle populations. The result will improve our understanding of the biological mechanisms of heat tolerance in African cattle breeds and opens an avenue for further study. © 2017 Japanese Society of Animal Science.

  12. In vivo and in vitro ivacaftor response in cystic fibrosis patients with residual CFTR function: N-of-1 studies.

    PubMed

    McGarry, Meghan E; Illek, Beate; Ly, Ngoc P; Zlock, Lorna; Olshansky, Sabrina; Moreno, Courtney; Finkbeiner, Walter E; Nielson, Dennis W

    2017-04-01

    Ivacaftor, a cystic fibrosis transmembrane conductance regulator (CFTR) potentiator, decreases sweat chloride concentration, and improves pulmonary function in 6% of cystic fibrosis (CF) patients with specific CFTR mutations. Ivacaftor increases chloride transport in many other CFTR mutations in non-human cells, if CFTR is in the epithelium. Some CF patients have CFTR in the epithelium with residual CFTR function. The effect of ivacaftor in these patients is unknown. This was a series of randomized, crossover N-of-1 trials of ivacaftor and placebo in CF patients ≥8 years old with potential residual CFTR function (intermediate sweat chloride concentration, pancreatic sufficient, or mild bronchiectasis on chest CT). Human nasal epithelium (HNE) was obtained via nasal brushing and cultured. Sweat chloride concentration change was the in vivo outcome. Chloride current change in HNE cultures with ivacaftor was the in vitro outcome. Three subjects had decreased sweat chloride concentration (-14.8 to -40.8 mmol/L, P < 0.01). Two subjects had unchanged sweat chloride concentration. Two subjects had increased sweat chloride concentration (+23.8 and +27.3 mmol/L, P < 0.001); both were heterozygous for A455E and pancreatic sufficient. Only subjects with decreased sweat chloride concentration had increased chloride current in HNE cultures. Some CF patients with residual CFTR function have decreased sweat chloride concentration with ivacaftor. Increased chloride current in HNE cultures among subjects with decreased sweat chloride concentrations may predict clinical response to ivacaftor. Ivacaftor can increase sweat chloride concentration in certain mutations with unclear clinical effect. Pediatr Pulmonol. 2017;52:472-479. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  13. Autonomous sweat extraction and analysis applied to cystic fibrosis and glucose monitoring using a fully integrated wearable platform

    DOE PAGES

    Emaminejad, Sam; Gao, Wei; Wu, Eric; ...

    2017-04-17

    Perspiration-based wearable biosensors facilitate continuous monitoring of individuals' health states with real-time and molecular-level insight. The inherent inaccessibility of sweat in sedentary individuals in large volume (≥10 μL) for on-demand and in situ analysis has limited our ability to capitalize on this noninvasive and rich source of information. A wearable and miniaturized iontophoresis interface is an excellent solution to overcome this barrier. The iontophoresis process involves delivery of stimulating agonists to the sweat glands with the aid of an electrical current. The challenge remains in devising an iontophoresis interface that can extract sufficient amount of sweat for robust sensing, withoutmore » electrode corrosion and burning/causing discomfort in subjects. Here, we overcame this challenge through realizing an electrochemically enhanced iontophoresis interface, integrated in a wearable sweat analysis platform. This interface can be programmed to induce sweat with various secretion profiles for real-time analysis, a capability which can be exploited to advance our knowledge of the sweat gland physiology and the secretion process. To demonstrate the clinical value of our platform, human subject studies were performed in the context of the cystic fibrosis diagnosis and preliminary investigation of the blood/sweat glucose correlation. With our platform, we detected the elevated sweat electrolyte content of cystic fibrosis patients compared with that of healthy control subjects. Furthermore, our results indicate that oral glucose consumption in the fasting state is followed by increased glucose levels in both sweat and blood. In conclusion, our solution opens the possibility for a broad range of noninvasive diagnostic and general population health monitoring applications.« less

  14. Biological Variation of Chloride and Sodium in Sweat Obtained by Pilocarpine Iontophoresis in Adults: How Sure are You About Sweat Test Results?

    PubMed

    Willems, Philippe; Weekx, Steven; Meskal, Anissa; Schouwers, Sofie

    2017-04-01

    The measurement of chloride and sodium concentrations in sweat is an important test for the diagnosis of cystic fibrosis (CF). The aim of this study was to assess the analytical variation (CV A ) and within-subject (CV I ) and between-subject (CV G ) biological variation of chloride and sodium concentrations in sweat, collected by pilocarpine iontophoresis and to determine their effect on the clinical interpretation of sweat test results. Twelve Caucasian adults (six male and six female) without symptoms suggestive for CF and with a mean age of 41 years (range 28-59) were included in the study. At least eight samples of sweat were collected from each individual by pilocarpine iontophoresis. Chloride and sodium concentrations were measured in duplicate for each sample using ion selective electrodes. After the removal of outliers, the CV A , CV I , and CV G of chloride and sodium were determined, and their impact on measurement uncertainty and reference change value were calculated. The CV A , CV I , and CV G of chloride in sweat samples were 6.5, 17.7, and 47.2%, respectively. The CV A , CV I , and CV G of sodium sweat samples were 6.0, 17.5, and 42.6%, respectively. Our study indicates that sweat chloride and sodium concentration results must be interpreted with great care. Different components of variation, particularly the biological variations, have a considerable impact on the interpretation of these results. If no pre-analytical, analytical, or post-analytical errors are suspected, repeated sweat testing to confirm first-measurement results might not be desirable.

  15. Transition duration of ingested deuterium oxide to eccrine sweat during exercise in the heat.

    PubMed

    Church, Adam; Lee, Fanny; Buono, Michael J

    2017-01-01

    The time necessary for the initial appearance of ingested water as sweat during exercise in the heat remains unknown. Based on the current literature, we estimated fluid transition through the body, from ingestion to appearance as sweat, to have a minimum time duration of approximately three minutes. The purpose of this study was to test this prediction and identify the time necessary for the initial enrichment of deuterium oxide (D 2 O) in sweat following ingestion during exercise in the heat. Eight participants performed moderate intensity (40% of maximal oxygen uptake) treadmill exercise in an environmental chamber (40°C, 40% rH) to induce active sweating. After fifteen minutes, while continuing to walk, participants consumed D 2 O (0.15mlkg -1 ) in a final volume of 50ml water. Scapular sweat samples were collected one minute prior to and ten minutes post-ingestion. Samples were analyzed for sweat D 2 O concentration using isotope ratio mass spectrometry and compared to baseline. Mean±SD ∆ sweat D 2 O concentration at minutes one and two post-ingestion were not significantly higher than baseline (0min). Minutes three (9±3ppm) through ten (23±11ppm) post-ingestion had ∆ sweat D 2 O concentrations significantly (P<0.05) higher than baseline. Such results suggest that ingested water rapidly transports across the mucosal membrane of the alimentary canal into the vasculature space, enters the extravascular fluid, and is actively secreted by the eccrine sweat glands onto the surface of the skin for potential evaporation in as little as three minutes during exercise in the heat. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. Leaching from the stratum corneum does not explain the previously reported elevated potassium ion concentration in sweat.

    PubMed

    Buono, Michael J; Stone, Michael; Cannon, Daniel T

    2016-03-01

    The purpose of this study was to determine if K+ is leached from the stratum corneum when sweat is present on the skin's surface. The results will help address whether sweat [K+] previously reported in the literature are artifactually elevated as a result of K+ leaching. Twelve (six female, six male) healthy volunteers participated in this study. After thorough skin cleansing and preparation with isopropyl alcohol and high-performance liquid chromatography-grade distilled water, three sites were chosen and a 50 μL drop of artificial sweat was pipetted directly onto the skin. The artificial sweat had a [K+] of 4 mEq·L-1, an osmolality of 120 mosm·L-1, and a pH of 6.0. Immediately following, a clear plastic cover slip (~6 cm2) with a shallow 0.8 cm2 convex impression in the center was applied over each drop, preventing evaporation. Each sample was allowed to sit on the forearm, under the plastic cover slip, for 10 min. The mean (±SD) [K+] in 'artificial' sweat not exposed to the skin was measured to be 4.2±0.4 mEq·L-1. After 10 min of exposure to the stratum corneum of the forearm, the artificial sweat had a mean (±SD) [K+] of 3.9±0.3 mEq·L-1. There was no significant difference (p>0.05) in the [K+] between the control artificial sweat and the samples collected after 10 min of exposure to forearm skin. These results do not support the hypothesis that significant K+ leaching from the stratum corneum into standing sweat is the cause for the previously reported elevated sweat [K+].

  17. A Preliminary Study of Biomonitoring for Bisphenol-A in Human Sweat.

    PubMed

    Porucznik, Christina A; Cox, Kyley J; Wilkins, Diana G; Anderson, David J; Bailey, Nicole M; Szczotka, Kathryn M; Stanford, Joseph B

    2015-09-01

    Measurement of human exposure to the endocrine disruptor bisphenol-A (BPA) is hampered by the ubiquitous but transient exposure for most individuals, coupled with a short metabolic half-life which leads to high inter- and intra-individual variability. We investigated the possibility of measuring multiday exposure to BPA in human sweat among volunteer participants with the goal of identifying an exposure assessment method less affected by temporal variability. We recruited 50 participants to wear a sweat collection patch (PharmChek(®)) for 7 days with concurrent collection of daily first-morning urine. Urines and sweat patch extracts were analyzed with quantitative LC-MS-MS using a method we previously validated. In addition, a human volunteer consumed one can of commercially available soup (16 oz, 473 cm(3)) daily for 3 days and collected urine. Sweat patches (n = 2, 1 per arm) were worn for the 3 days of the study. BPA was detected in quality control specimens prepared by fortification of BPA to sweat patches, but was only detected at 5× above average background on three participant patches. Although the highest measured urine BPA concentration was 195 ng/mL for an individual with deliberate exposure, no BPA was detected above background in the corresponding sweat patches. In this preliminary investigation, the use of sweat patches primarily worn on the upper-outer arm did not detect BPA exposures that were documented by urine monitoring. The absence of BPA in sweat patches may be due to several factors, including insufficient quantity of specimen per patch, or extremely low concentrations of BPA in naturally occurring sweat, among others. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  18. Autonomous sweat extraction and analysis applied to cystic fibrosis and glucose monitoring using a fully integrated wearable platform

    PubMed Central

    Emaminejad, Sam; Gao, Wei; Wu, Eric; Davies, Zoe A.; Yin Yin Nyein, Hnin; Challa, Samyuktha; Ryan, Sean P.; Fahad, Hossain M.; Chen, Kevin; Shahpar, Ziba; Talebi, Salmonn; Milla, Carlos; Javey, Ali; Davis, Ronald W.

    2017-01-01

    Perspiration-based wearable biosensors facilitate continuous monitoring of individuals’ health states with real-time and molecular-level insight. The inherent inaccessibility of sweat in sedentary individuals in large volume (≥10 µL) for on-demand and in situ analysis has limited our ability to capitalize on this noninvasive and rich source of information. A wearable and miniaturized iontophoresis interface is an excellent solution to overcome this barrier. The iontophoresis process involves delivery of stimulating agonists to the sweat glands with the aid of an electrical current. The challenge remains in devising an iontophoresis interface that can extract sufficient amount of sweat for robust sensing, without electrode corrosion and burning/causing discomfort in subjects. Here, we overcame this challenge through realizing an electrochemically enhanced iontophoresis interface, integrated in a wearable sweat analysis platform. This interface can be programmed to induce sweat with various secretion profiles for real-time analysis, a capability which can be exploited to advance our knowledge of the sweat gland physiology and the secretion process. To demonstrate the clinical value of our platform, human subject studies were performed in the context of the cystic fibrosis diagnosis and preliminary investigation of the blood/sweat glucose correlation. With our platform, we detected the elevated sweat electrolyte content of cystic fibrosis patients compared with that of healthy control subjects. Furthermore, our results indicate that oral glucose consumption in the fasting state is followed by increased glucose levels in both sweat and blood. Our solution opens the possibility for a broad range of noninvasive diagnostic and general population health monitoring applications. PMID:28416667

  19. Autonomous sweat extraction and analysis applied to cystic fibrosis and glucose monitoring using a fully integrated wearable platform

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Emaminejad, Sam; Gao, Wei; Wu, Eric

    Perspiration-based wearable biosensors facilitate continuous monitoring of individuals' health states with real-time and molecular-level insight. The inherent inaccessibility of sweat in sedentary individuals in large volume (≥10 μL) for on-demand and in situ analysis has limited our ability to capitalize on this noninvasive and rich source of information. A wearable and miniaturized iontophoresis interface is an excellent solution to overcome this barrier. The iontophoresis process involves delivery of stimulating agonists to the sweat glands with the aid of an electrical current. The challenge remains in devising an iontophoresis interface that can extract sufficient amount of sweat for robust sensing, withoutmore » electrode corrosion and burning/causing discomfort in subjects. Here, we overcame this challenge through realizing an electrochemically enhanced iontophoresis interface, integrated in a wearable sweat analysis platform. This interface can be programmed to induce sweat with various secretion profiles for real-time analysis, a capability which can be exploited to advance our knowledge of the sweat gland physiology and the secretion process. To demonstrate the clinical value of our platform, human subject studies were performed in the context of the cystic fibrosis diagnosis and preliminary investigation of the blood/sweat glucose correlation. With our platform, we detected the elevated sweat electrolyte content of cystic fibrosis patients compared with that of healthy control subjects. Furthermore, our results indicate that oral glucose consumption in the fasting state is followed by increased glucose levels in both sweat and blood. In conclusion, our solution opens the possibility for a broad range of noninvasive diagnostic and general population health monitoring applications.« less

  20. Gender differences in the sweat response during spinning exercise.

    PubMed

    Hazelhurst, Lynton T; Claassen, Nicolaas

    2006-08-01

    The purpose of this field study was to examine gender differences in the sweat response reported in the literature in trained men and women during indoor cycling. In the present study, 14 men and 12 women took part in a 90-minute spinning class in preparation for a 108-km road race. Delta body mass, corrected for the volume of water consumed, was used to estimate sweat loss during the exercise period. Men had a significantly higher sweat rate (1.12 L.h(-1)) compared to women (0.57 L.h(-1)), despite the fact that there were no significant gender differences in ad libitum fluid intake. Future research should focus on determining whether women may be more efficient in sweat production and evaporation and whether men may have a greater reserve capacity for increased sweating.

  1. Technical note: Method for isolation of the bovine sweat gland and conditions for in vitro culture.

    PubMed

    Hamzaoui, S; Burger, C A; Collier, J L; Collier, R J

    2018-05-01

    Apocrine sweat glands in bovine skin are involved in thermoregulation. Human, horse, and sheep sweat gland epithelial cells have been isolated and grown in vitro. The present study was conducted to identify a method to isolate bovine sweat glands and culture apocrine bovine sweat gland epithelial cells in vitro. Mechanical shearing, collagenase digestion, centrifugation, and neutral red staining were used to identify and isolate the apocrine glands from skin. Bovine sweat glands in situ and after isolation comprised 2 major cell types consisting of a single layer of cuboidal epithelial cells resting on a layer of myoepithelial cells. In situ, the glands were embedded in a collagen matrix primarily comprising fibroblasts, and some of these cells were also present in the isolated material. The isolated material was transferred to complete medium (keratinocyte serum-free medium, bovine pituitary extract, and human recombinant epidermal growth factor + 2.5% fetal bovine serum) in a T 25 flask (Falcon, Franklin Lakes, NJ) with media film and then incubated at 37°C for 24 h. After sweat glands adhered to the bottom of the flask, an additional 2 mL of complete medium was added and the medium was changed every 3 d. Isolated apocrine sweat glands and bovine sweat gland epithelial cells were immunostained for cytokeratin and fibroblast specific protein, indicating fibroblast-free cultures. Copyright © 2018 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  2. Highly abundant defense proteins in human sweat as revealed by targeted proteomics and label-free quantification mass spectrometry.

    PubMed

    Csősz, É; Emri, G; Kalló, G; Tsaprailis, G; Tőzsér, J

    2015-10-01

    The healthy human skin with its effective antimicrobial defense system forms an efficient barrier against invading pathogens. There is evidence suggesting that the composition of this chemical barrier varies between diseases, making the easily collected sweat an ideal candidate for biomarker discoveries. Our aim was to provide information about the normal composition of the sweat, and to study the chemical barrier found at the surface of skin. Sweat samples from healthy individuals were collected during sauna bathing, and the global protein panel was analysed by label-free mass spectrometry. SRM-based targeted proteomic methods were designed and stable isotope labelled reference peptides were used for method validation. Ninety-five sweat proteins were identified, 20 of them were novel proteins. It was shown that dermcidin is the most abundant sweat protein, and along with apolipoprotein D, clusterin, prolactin-inducible protein and serum albumin, they make up 91% of secreted sweat proteins. The roles of these highly abundant proteins were reviewed; all of which have protective functions, highlighting the importance of sweat glands in composing the first line of innate immune defense system, and maintaining the epidermal barrier integrity. Our findings with regard to the proteins forming the chemical barrier of the skin as determined by label-free quantification and targeted proteomics methods are in accordance with previous studies, and can be further used as a starting point for non-invasive sweat biomarker research. © 2015 European Academy of Dermatology and Venereology.

  3. Low abundance of sweat duct Cl− channel CFTR in both healthy and cystic fibrosis athletes with exceptionally salty sweat during exercise

    PubMed Central

    Haack, Karla K. V.; Pollack, Brian P.; Millard-Stafford, Mindy; McCarty, Nael A.

    2011-01-01

    To understand potential mechanisms explaining interindividual variability observed in human sweat sodium concentration ([Na+]), we investigated the relationship among [Na+] of thermoregulatory sweat, plasma membrane expression of Na+ and Cl− transport proteins in biopsied human eccrine sweat ducts, and basal levels of vasopressin (AVP) and aldosterone. Lower ductal luminal membrane expression of the Cl− channel cystic fibrosis transmembrane conductance regulator (CFTR) was observed in immunofluorescent staining of sweat glands from healthy young adults identified as exceptionally “salty sweaters” (SS) (n = 6, P < 0.05) and from patients with cystic fibrosis (CF) (n = 6, P < 0.005) compared with ducts from healthy young adults with “typical” sweat [Na+] (control, n = 6). Genetic testing of healthy subjects did not reveal any heterozygotes (“carriers”) for any of the 39 most common disease-causing CFTR mutations in the United States. SS had higher baseline plasma [AVP] compared with control (P = 0.029). Immunostaining to investigate a potential relationship between higher plasma [AVP] (and sweat [Na+]) and ductal membrane aquaporin-5 revealed for all groups a relatively sparse and location-dependent ductal expression of the water channel with localization primarily to the secretory coil. Availability of CFTR for NaCl transport across the ductal membrane appears related to the significant physiological variability observed in sweat salt concentration in apparently healthy humans. At present, a heritable link between healthy salty sweaters and the most prevalent disease-causing CFTR mutations cannot be established. PMID:21228336

  4. Biological variability of the sweat chloride in diagnostic sweat tests: A retrospective analysis.

    PubMed

    Vermeulen, F; Lebecque, P; De Boeck, K; Leal, T

    2017-01-01

    The sweat test is the current gold standard for the diagnosis of cystic fibrosis (CF). CF is unlikely when sweat chloride (Cl sw ) is lower than 30mmol/L, Cl sw >60 is suggestive of CF, with intermediate values between 30 and 60mmol/L. To correctly interpret a sweat chloride value, the biological variability of the sweat chloride has to be known. Sweat tests performed in two centers using the classic Gibson and Cooke method were retrospectively reviewed (n=5904). Within test variability of Cl sw was measured by comparing results from right and left arm collected on the same day. Between test variability was calculated from subjects with sweat tests performed on more than one occasion. Within test variability of Cl sw calculated in 1022 subjects was low with differences between -3.2 (p5) and +3.6mmol/L (p95). Results from left and right arm were classified differently in only 3 subjects. Between test variability of Cl sw in 197 subjects was larger, with differences between -18.2mmol/L (p5) and +14.1mmol/L (p95) between repeat tests. Changes in diagnostic conclusion were seen in 55/197 subjects, the most frequent being changing from indeterminate to 'CF unlikely' range (48/102). Variability of sweat chloride is substantial, with frequent changes in diagnostic conclusion, especially in the intermediate range. Copyright © 2016 European Cystic Fibrosis Society. Published by Elsevier B.V. All rights reserved.

  5. The detection of cortisol in human sweat: implications for measurement of cortisol in hair.

    PubMed

    Russell, Evan; Koren, Gideon; Rieder, Michael; Van Uum, Stan H M

    2014-02-01

    Hair cortisol analysis has been shown to be an effective measure of chronic stress. Cortisol is assumed to incorporate into hair via serum, sebum, and sweat sources; however, the extent to which sweat contributes to hair cortisol content is unknown. Sweat and saliva samples were collected from 17 subjects after a period of intensive exercise and analyzed by salivary enzyme-linked immunosorbent assay (ELISA). Subsequently, an in vitro test on exposure of hair to hydrocortisone was conducted. Residual hair samples were immersed in a 50-ng/mL hydrocortisone solution for periods lasting 15 minutes to 24 hours, followed by a wash or no-wash condition. Hair cortisol content was determined using our modified protocol for a salivary ELISA. Postexercise control sweat cortisol concentrations ranged from 8.16 to 141.7 ng/mL and correlated significantly with the log-transformed time of day. Sweat cortisol levels significantly correlated with salivary cortisol concentrations. In vitro hair exposure to a 50-ng/mL hydrocortisone solution (mimicking sweat) for 60 minutes or more resulted in significantly increased hair cortisol concentrations. Washing with isopropanol did not affect immersion-increased hair cortisol concentrations. Human sweat contains cortisol in concentrations comparable with salivary cortisol levels. This study suggests that perfuse sweating after intense exercise may increase cortisol concentrations detected in hair. This increase likely cannot be effectively decreased with conventional washing procedures and should be considered carefully in studies using hair cortisol as a biomarker of chronic stress.

  6. Non-invasive diagnosis of sweat gland dysplasia using optical coherence tomography and reflectance confocal microscopy in a family with anhidrotic ectodermal dysplasia (Christ-Siemens-Touraine syndrome).

    PubMed

    Reinholz, M; Gauglitz, G G; Giehl, K; Braun-Falco, M; Schwaiger, H; Schauber, J; Ruzicka, T; Berneburg, M; von Braunmühl, T

    2016-04-01

    Anhidrotic ectodermal dysplasia (AED) is an inherited syndrome, which originates mainly from genetic alteration of the ectodysplasin A (EDA) gene. It regularly affects the adnexa of the skin which results in a characteristic phenotype of the patients including hypo- or anhidrosis leading to severe disturbances in the regulation of body temperature. To prevent the development of the symptoms in early childhood promising therapeutic approaches are currently under clinical investigation. In this context, timely diagnosis of this genetic syndrome is crucial. The purpose of our study was the investigation of modern non-invasive imaging methods such as optical coherence tomography (OCT) and reflectance confocal microscopy (RCM) in the immediate diagnosis of AED. We examined a 3-year-old boy with the suspicion for an AED syndrome and his family members with RCM and OCT to document presence and characteristic features of sweat glands in comparison to non-affected individuals. The patient and the affected brother showed significantly reduced sweat glands in the imaging compared to the controls. The genetic analysis revealed a mutation of the EDA gene for hemizygosity previously associated with AED and the mother was revealed as the conductor of the genetic alteration. With the help of non-invasive imaging, we were able to detect sweat gland dysplasia in the affected family members without performing a biopsy which led us to the diagnosis of an AED. The application of modern dermatological imaging techniques might serve as valuable supplementary tools in the immediate, non-invasive diagnosis of genetic syndromes especially in newborns when early therapeutic approaches are planned. © 2015 European Academy of Dermatology and Venereology.

  7. Lumped versus distributed thermoregulatory control: results from a three-dimensional dynamic model.

    PubMed

    Werner, J; Buse, M; Foegen, A

    1989-01-01

    In this study we use a three-dimensional model of the human thermal system, the spatial grid of which is 0.5 ... 1.0 cm. The model is based on well-known physical heat-transfer equations, and all parameters of the passive system have definite physical values. According to the number of substantially different areas and organs, 54 spatially different values are attributed to each physical parameter. Compatibility of simulation and experiment was achieved solely on the basis of physical considerations and physiological basic data. The equations were solved using a modification of the alternating direction implicit method. On the basis of this complex description of the passive system close to reality, various lumped and distributed parameter control equations were tested for control of metabolic heat production, blood flow and sweat production. The simplest control equations delivering results on closed-loop control compatible with experimental evidence were determined. It was concluded that it is essential to take into account the spatial distribution of heat production, blood flow and sweat production, and that at least for control of shivering, distributed controller gains different from the pattern of distribution of muscle tissue are required. For sweat production this is not so obvious, so that for simulation of sweating control after homogeneous heat load a lumped parameter control may be justified. Based on these conclusions three-dimensional temperature profiles for cold and heat load and the dynamics for changes of the environmental conditions were computed. In view of the exact simulation of the passive system and the compatibility with experimentally attainable variables there is good evidence that those values extrapolated by the simulation are adequately determined. The model may be used both for further analysis of the real thermoregulatory mechanisms and for special applications in environmental and clinical health care.

  8. Quantitative comparison of topical aluminum salt solution efficacy for management of sweating: a randomized, controlled trial.

    PubMed

    Swary, Jillian H; West, Dennis P; Kakar, Rohit; Ortiz, Sara; Schaeffer, Matthew R; Veledar, Emir; Alam, Murad

    2015-12-01

    There is a lack of studies objectively comparing the efficacy of topical antiperspirants in reducing sweat. To objectively and quantitatively compare the efficacy of two aluminum salt solutions for the reduction of induced sweating. A subject, rater, and statistician-blinded, randomized, controlled trial. Nineteen subjects were exposed to a standardized heat challenge for 3 h. Topical agent A (20% aluminum chloride hexahydrate) was randomized to either axilla, and topical agent B (1% aluminum acetate) assigned to the contralateral side. A sauna suit induced sweating during three 30-min heat intervals: (1) with no study agents (pre); (2) with both study agents, one on each side; and (3) after the agents were washed off (post). Sweat levels were measured by securing Whatman(®) filter paper to each axilla and measuring the paper weight after each heat interval. The difference in paper weight following each heat interval between Study Agent A and Study Agent B was measured by a gravimetric scale. Topical agent A had a significantly greater effect at reducing axillary sweating than B (P = 0.0002). In a sweating simulation, 20% aluminum chloride hexahydrate quantitatively and objectively appeared to reduce sweat more effectively than 1% aluminum acetate. © 2015 Wiley Periodicals, Inc.

  9. Immunohistochemical sweat gland profiles.

    PubMed

    Noël, Fanchon; Piérard, Gérald E; Delvenne, Philippe; Quatresooz, Pascale; Humbert, Philippe; Piérard-Franchimont, Claudine

    2013-09-01

    Human sweat glands are heterogeneous in their structures and functions. Accordingly, eccrine, apocrine, and apoeccrine glands are distinguished. Some immunohistochemical markers are expected to distinguish the sweat gland types in their secretory and excretory parts. This study used two sets of antibodies. The first panel was composed of antibodies directed to well-defined sweat gland structures. The molecular targets included the low-molecular-weight cytokeratins CAM 5.2, the S100-B protein, the epithelial membrane antigen (EMA), the carcinoembryonic antigen (CEA), and the lectin Ulex europaeus agglutinin-1 (UEA-1). A second exploratory panel of antibodies targeted syndecan-1 (CD138), NKI-C3 (CD63), and CD68. They were used to disclose some undescribed antigen expressions in human sweat glands. The first set of antibodies confirmed previous findings. The immunoreactivities of the three sweat gland types were similar in the excretory ducts. By contrast, they were distinguished in the deeper coiled secretory portions of the glands. Clues supporting their distinction and probably their functional activity were obtained by immunohistochemistry using the S100-B protein, CEA and CD63 antibodies. The immunoreactivity to the S100-B protein, CEA and CD63 possibly help identifying apoeccrine sweat glands or a peculiar functional activity of eccrine sweat glands. © 2013 Wiley Periodicals, Inc.

  10. Audit of sweat testing: a first report from Italian Cystic Fibrosis Centres.

    PubMed

    Cirilli, Natalia; Padoan, Rita; Raia, Valeria

    2008-09-01

    Cystic Fibrosis diagnosis is confirmed using sweat test. The aim of our study was to evaluate current techniques and methodologies in use at Italian CF Care Centres. A series of questions related to the performance of the sweat test was collected by all CF Care Centres in Italy. Answers were compared with UK and NCCLS guidelines. 39/41 Centres replied to the questionnaire. A good adherence to guidelines was registered for storing samples before analysis in 90.9%, while performing CF diagnosis by at least two sweat tests, and chloride analysis were reported respectively in 100% and 75.7% of Centres. Some inconsistencies were registered for minimum acceptable sweat quantity and time to collect sweat inadequate in respectively 42.5% and 24.2% of Centres, while performing quality control procedures and referring to an external quality assessment scheme were found inadequate in respectively 54.6% and 100%. 57.6% didn't provide any appropriate analytical ranges and only 15.1% of Centres offered proper information to patients/parents. A report form, including sweat quantity, reference ranges and interpretation, was adequate only for 9.4 up to 41.4% of CF Centres. Our study showed areas of inconsistencies in sweat testing current practices in Italy and highlights the need for evidence based national guidelines to improve practice and management strategies.

  11. The ultrastructure of the sweat glands of the ox, sheep and goat during sweating and recovery.

    PubMed Central

    Jenkinson, D M; Montgomery, I; Elder, H Y

    1979-01-01

    The ultrastructure of the sweat glands of cattle, sheep and goats was studied before, during, and after, exposure of the animals to controlled warm environments. In cattle, sweating induced little ultrastructural change in the gland, although fluid-filled spaces appeared between the myo- and secretory epithelial layers. The mechanism appears to be one of fluid transport and exocytosis of secretory vesicles, which in this species seem to be derived from the Golgi apparatus and/or mitochondria. The glands of the sheep and goat also displayed signs of vesicle exocytosis and of fluid transport during sweating. The sweating 'fatigue' in these species was apparently due to failure of the secretory cells, some of which ruptured and were extruded into the lumen. The evidence during subsequent recovery indicates that neighbouring cells spread to make contact, encase remnants of atretic cells between them and the underlying myoepithelium, and engulf them. Sweat in these species appears to be formed (a) by secretion and (b) from cells which can no longer meet the demands of stimulation. The role in sweating of cell replacement, and of undifferentiated cells found between the myo- and secretory epithelia, is discussed. Images Fig. 3 Fig. 4 Fig. 5 Fig. 6 Fig. 7 Fig. 8 Fig. 9 Fig. 10 PMID:511758

  12. Validity of infrared tympanic temperature for the evaluation of heat strain while wearing impermeable protective clothing in hot environments.

    PubMed

    Lee, Joo-Young; Nakao, Kouhei; Takahashi, Naoki; Son, Su-Young; Bakri, Ilham; Tochihara, Yutaka

    2011-01-01

    The purpose of this study was to investigate the validity of infrared tympanic temperature (IR T(ty)) as a thermal index to evaluate the heat strain of workers in hot environments, in comparison with rectal temperatures at various depths (T(re-4, -8, and -16) for 4, 8 and 16 cm from the anal sphincter). Eight males underwent twelve experimental conditions: two activities (rest and exercise) × three clothing levels [Control, HDPE (high-density polyethylene coverall) and PVC (polyvinyl chloride coverall) condition] × two air temperatures (25 and 32℃ with 50%RH). The results showed that 1) in the conditions with most heat strain (HDPE or PVC condition at 32℃), IR T(ty) was equal to or even higher than T(re); 2) during exercise, physiological strain index (PSI) using IR T(ty) did not underestimate PSI-values using T(re-16), and overestimated those PSI-values from T(re-16) in HDPE and PVC conditions at 32℃; 3) during exercise, the relationships between IR T(ty) and heart and total sweat rate were stronger than those between T(re-16) and heart and total sweat rate. These results indicated that IR T(ty) is valid as a thermal index to evaluate the heat strain of workers wearing impermeable protective coveralls in hot environments. However, the application of IR T(ty) is limited only for strenuous works wearing encapsulated personal protective clothing with a hood in heat.

  13. Bioanalytical devices: Technological leap for sweat sensing

    NASA Astrophysics Data System (ADS)

    Heikenfeld, Jason

    2016-01-01

    Sweat analysis is an ideal method for continuously tracking a person's physiological state, but developing devices for this is difficult. A wearable sweat monitor that measures several biomarkers is a breakthrough. See Letter p.509

  14. Higher sweat chloride levels in patients with asthma: a case-control study.

    PubMed

    Awasthi, Shally; Dixit, Pratibha; Maurya, Nutan

    2015-02-01

    To screen asthmatic patients by sweat chloride test to identify proportion with Cystic Fibrosis (CF); (Sweat chloride level >60 mmol/L). Also, to compare sweat chloride levels between cases of bronchial asthma and age and sex matched healthy children aged 5 mo-15 y. The present case-control study was conducted in a tertiary care hospital in India. Cases of bronchial asthma, diagnosed by GINA guideline 2008, and age matched healthy controls were included. Case to control ratio was 2:1. Sweat Chloride test was done by Pilocarpine Iontophoresis method. From April 2010 through May 2012, 216 asthmatics and 112 controls were recruited. Among asthmatics, there was no case of Cystic Fibrosis. Mean sweat chloride levels in asthmatics was 22.39 ± 8.45 mmol/L (inter-quartile range - 15-28 mmol/L) and in controls 19.55 ± 7.04 mmol/L (inter-quartile range - 15-23.5 mmol/L) (p value = 0.048). No Cystic Fibrosis case was identified among asthmatics. Mean sweat chloride levels were higher in asthmatics as compared to controls.

  15. On sweat analysis for quantitative estimation of dehydration during physical exercise.

    PubMed

    Ring, Matthias; Lohmueller, Clemens; Rauh, Manfred; Eskofier, Bjoern M

    2015-08-01

    Quantitative estimation of water loss during physical exercise is of importance because dehydration can impair both muscular strength and aerobic endurance. A physiological indicator for deficit of total body water (TBW) might be the concentration of electrolytes in sweat. It has been shown that concentrations differ after physical exercise depending on whether water loss was replaced by fluid intake or not. However, to the best of our knowledge, this fact has not been examined for its potential to quantitatively estimate TBW loss. Therefore, we conducted a study in which sweat samples were collected continuously during two hours of physical exercise without fluid intake. A statistical analysis of these sweat samples revealed significant correlations between chloride concentration in sweat and TBW loss (r = 0.41, p <; 0.01), and between sweat osmolality and TBW loss (r = 0.43, p <; 0.01). A quantitative estimation of TBW loss resulted in a mean absolute error of 0.49 l per estimation. Although the precision has to be improved for practical applications, the present results suggest that TBW loss estimation could be realizable using sweat samples.

  16. Association of sweat chloride concentration at time of diagnosis and CFTR genotype with mortality and cystic fibrosis phenotype.

    PubMed

    McKone, Edward F; Velentgas, Priscilla; Swenson, Anna J; Goss, Christopher H

    2015-09-01

    The extent to which sweat chloride concentration predicts survival and clinical phenotype independently of CFTR genotype in cystic fibrosis is not well understood. We analyzed the US Cystic Fibrosis Foundation Patient Registry data using Cox regression to examine the relationship between sweat chloride concentration (<60, 60-<80, ≥80mmol/L), CFTR genotype (high and lower risk for lung function decline), and survival and mixed linear regression to examine the relationship between sweat chloride, CFTR genotype, and measures of lung function and growth. When included in the same model, CFTR genotype, but not sweat chloride, was independently associated with survival and with lung function, height, and BMI. Among patients with unclassified CFTR genotype, sweat chloride was an independent predictor of survival (<60 HR 0.53 [0.37, 0.77], 60-<80 0.51 [0.42, 0.63]). Sweat chloride concentration may be a useful predictor of mortality and clinical phenotype when CFTR genotype functional class is unclassified. Copyright © 2015 European Cystic Fibrosis Society. Published by Elsevier B.V. All rights reserved.

  17. Sweating Like a Pig: Physics or Irony?

    NASA Astrophysics Data System (ADS)

    Bohren, Craig F.

    2016-03-01

    In his interesting and informative book Is That a Fact?, Joe Schwarcz avers that pigs do not sweat and the saying "sweating like a pig" originates in iron smelting. Oblong pieces of hot iron, with a fancied resemblance to a sow with piglets, cool in sand to the dew point of the surrounding air, and hence water condenses on the "pig." But this explanation, which I have seen on the Internet, lacks a few caveats. It implies that molten iron, solidifying and cooling, anywhere, anytime, accretes liquid water, as if this were a special property of cooling iron. Set aside that real pigs sweat perceptibly from their snouts; kiss a pig and verify for yourself. Pigs also sweat imperceptibly. Imperceptible (insensible) perspiration is water vapor from the skin and lungs exuded without sensible condensation. That from humans is about 1 liter/day. Sweat is 99% liquid water, NaCl the dominant solute, secreted quickly, sometimes profusely, by subcutaneous sweat glands in response to thermal stress, in contrast to the slow, continuous diffusion of water vapor through skin.

  18. A comparison of hydration effect on body fluid and temperature regulation between Malaysian and Japanese males exercising at mild dehydration in humid heat.

    PubMed

    Wakabayashi, Hitoshi; Wijayanto, Titis; Lee, Joo-Young; Hashiguchi, Nobuko; Saat, Mohamed; Tochihara, Yutaka

    2014-02-04

    This study investigated the effect of hydration differences on body fluid and temperature regulation between tropical and temperate indigenes exercising in the heat. Ten Japanese and ten Malaysian males with matched physical characteristics (height, body weight, and peak oxygen consumption) participated in this study. Participants performed exercise for 60 min at 55% peak oxygen uptake followed by a 30-min recovery at 32°C and 70% relative air humidity with hydration (4 times each, 3 mL per kg body weight, 37°C) or without hydration. Rectal temperature, skin temperature, heart rate, skin blood flow, and blood pressure were measured continuously. The percentage of body weight loss and total sweat loss were calculated from body weight measurements. The percentage change in plasma volume was estimated from hemoglobin concentration and hematocrit. Malaysian participants had a significantly lower rectal temperature, a smaller reduction in plasma volume, and a lower heart rate in the hydrated condition than in the non-hydrated condition at the end of exercise (P <0.05), whereas Japanese participants showed no difference between the two hydration conditions. Hydration induced a greater total sweat loss in both groups (P <0.05), and the percentage of body weight loss in hydrated Malaysians was significantly less than in hydrated Japanese (P <0.05). A significant interaction between groups and hydration conditions was observed for the percentage of mean cutaneous vascular conductance during exercise relative to baseline (P <0.05). The smaller reduction in plasma volume and percentage body weight loss in hydrated Malaysians indicated an advantage in body fluid regulation. This may enable Malaysians to reserve more blood for circulation and heat dissipation and thereby maintain lower rectal temperatures in a hydrated condition.

  19. Discriminating the precipitation phase based on different temperature thresholds in the Songhua River Basin, China

    NASA Astrophysics Data System (ADS)

    Zhong, Keyuan; Zheng, Fenli; Xu, Ximeng; Qin, Chao

    2018-06-01

    Different precipitation phases (rain, snow or sleet) differ greatly in their hydrological and erosional processes. Therefore, accurate discrimination of the precipitation phase is highly important when researching hydrologic processes and climate change at high latitudes and mountainous regions. The objective of this study was to identify suitable temperature thresholds for discriminating the precipitation phase in the Songhua River Basin (SRB) based on 20-year daily precipitation collected from 60 meteorological stations located in and around the basin. Two methods, the air temperature method (AT method) and the wet bulb temperature method (WBT method), were used to discriminate the precipitation phase. Thirteen temperature thresholds were used to discriminate snowfall in the SRB. These thresholds included air temperatures from 0 to 5.5 °C at intervals of 0.5 °C and the wet bulb temperature (WBT). Three evaluation indices, the error percentage of discriminated snowfall days (Ep), the relative error of discriminated snowfall (Re) and the determination coefficient (R2), were applied to assess the discrimination accuracy. The results showed that 2.5 °C was the optimum threshold temperature for discriminating snowfall at the scale of the entire basin. Due to differences in the landscape conditions at the different stations, the optimum threshold varied by station. The optimal threshold ranged 1.5-4.0 °C, and 19 stations, 17 stations and 18 stations had optimal thresholds of 2.5 °C, 3.0 °C, and 3.5 °C respectively, occupying 90% of all stations. Compared with using a single suitable temperature threshold to discriminate snowfall throughout the basin, it was more accurate to use the optimum threshold at each station to estimate snowfall in the basin. In addition, snowfall was underestimated when the temperature threshold was the WBT and when the temperature threshold was below 2.5 °C, whereas snowfall was overestimated when the temperature threshold exceeded 4.0 °C at most stations. The results of this study provide information for climate change research and hydrological process simulations in the SRB, as well as provide reference information for discriminating precipitation phase in other regions.

  20. Development of a screening system for cystic fibrosis.

    PubMed

    Coury, A J; Fogt, E J; Norenberg, M S; Untereker, D F

    1983-09-01

    We have developed a simple method for detecting high concentrations of chloride in sweat from ambulatory subjects, a measurement useful in the detection of cystic fibrosis. The method is based on the standard approach of stimulating sweat generation through iontophoresis of pilocarpine nitrate into the skin, followed by collection and analysis of the sweat for chloride concentration. The sweat-stimulating reagents are contained in polymeric gel pads, which are used in conjunction with a small battery-powered stimulator. The chloride analysis is subsequently done on the stimulated site by use of a thin test patch that picks up a fixed amount of sweat and changes color if the chloride concentration is higher than a predetermined value. The successful completion of a test is indicated by a fill tab, which changes color when the appropriate amount of sweat has been picked up by the chloride test patch.

  1. Cows exposed to heat stress during fetal life exhibit improved thermal tolerance.

    PubMed

    Ahmed, B M S; Younas, U; Asar, T O; Dikmen, S; Hansen, P J; Dahl, G E

    2017-08-01

    Maternal heat stress during late gestation affects calf function during postnatal life. The objective of the present study was to evaluate whether calves that experience heat stress in utero have altered thermoregulatory responses to acute heat stress later in life. Specifically, the hypothesis was that heat stress in utero would improve the response to acute heat stress at maturity. Females were born to dams exposed to heat stress or cooled during late gestation preceding their birth. All animals were raised postnatally under identical management. Twelve lactating Holstein cows that were exposed to in utero heat stress (HT) and 12 that were exposed to in utero control (CON) were used. A heat stress challenge was conducted in 3 blocks using 4 HT and 4 CON cows matched according to milk yield, stage of lactation, and parity. Each challenge consisted of transfer from a barn with shade and evaporative cooling to one with shade but no additional cooling for 48 h. The challenge was replicated twice for each block. Sweating rate, respiration rate, rectal temperature (RT), and skin temperature were measured on each cow at 0900, 1100, 1300, 1500, and 1700 h for 2 consecutive days. Mean ambient temperature across 6 challenge days was 26.15 ± 4.75°C. Tendencies for differences at 1700 h were observed between treatments for RT (HT: 39.5 ± 0.1; CON: 39.6 ± 0.1°C; = 0.065), however, there was no difference in respiration rate (HT: 77.6 ± 1.6; CON: 79.5 ± 1.6 bpm; = 0.85). Sweating rate for shaved skin (HT: 29.4 ± 2.0; CON: 36.0 ± 2.0 g/mh; = 0.057) and for non-shaved skin (HT: 22.5 ± 1.5; CON: 29.2 ± 1.2 g/mh; = 0.01) differed between groups. However, there was no effect on skin temperature at the shaved location (HT: 36.2 ± 0.2; CON: 36.0 ± 0.2°C; = 0.81), but there was a tendency for differences for the non-shaved area (HT: 35.4 ± 0.2; CON: 34.9 ± 0.2°C; = 0.097). Cows that underwent in utero heat stress had greater skin temperature at 1700 h vs. in utero control cows, which may be because HT cows increased skin perfusion, and consequently greater cooling via conduction. In utero HT cows would then have higher heat loss and reduced core body temperature, which results in lower rectal temperature and lower sweating rate when exposed to heat stress. These results support the hypothesis that heat stress in utero in late gestation increases heat tolerance at maturity by increasing capacity to dissipate heat to maintain core body temperature.

  2. Definition of temperature thresholds: the example of the French heat wave warning system.

    PubMed

    Pascal, Mathilde; Wagner, Vérène; Le Tertre, Alain; Laaidi, Karine; Honoré, Cyrille; Bénichou, Françoise; Beaudeau, Pascal

    2013-01-01

    Heat-related deaths should be somewhat preventable. In France, some prevention measures are activated when minimum and maximum temperatures averaged over three days reach city-specific thresholds. The current thresholds were computed based on a descriptive analysis of past heat waves and on local expert judgement. We tested whether a different method would confirm these thresholds. The study was set in the six cities of Paris, Lyon, Marseille, Nantes, Strasbourg and Limoges between 1973 and 2003. For each city, we estimated the excess in mortality associated with different temperature thresholds, using a generalised additive model, controlling for long-time trends, seasons and days of the week. These models were used to compute the mortality predicted by different percentiles of temperatures. The thresholds were chosen as the percentiles associated with a significant excess mortality. In all cities, there was a good correlation between current thresholds and the thresholds derived from the models, with 0°C to 3°C differences for averaged maximum temperatures. Both set of thresholds were able to anticipate the main periods of excess mortality during the summers of 1973 to 2003. A simple method relying on descriptive analysis and expert judgement is sufficient to define protective temperature thresholds and to prevent heat wave mortality. As temperatures are increasing along with the climate change and adaptation is ongoing, more research is required to understand if and when thresholds should be modified.

  3. 78 FR 41716 - Hours of Service; Limited 90-Day Waiver From the 30-Minute Rest Break Requirement for the...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-07-11

    ..., is a significant concern to the agricultural industry. The animals face a variety of stresses... the transportation of pigs because these animals do not sweat and are subject to heat stress. When heat stress occurs, a pig's body temperature rises to a level that it cannot control through its normal...

  4. The human thermoneutral and thermal comfort zones: Thermal comfort in your own skin blood flow.

    PubMed

    Schlader, Zachary J

    2015-01-01

    Human thermoregulation is achieved via autonomic and behavioral responses. Autonomic responses involve 2 synchronous 'components'. One counteracts large thermal perturbations, eliciting robust heat loss or gain (i.e., sweating or shivering). The other fends off smaller insults, relying solely on changes in sensible heat exchange (i.e., skin blood flow). This sensible component occurs within the thermoneutral zone [i.e., the ambient temperature range in which temperature regulation is achieved only by sensible heat transfer, without regulatory increases in metabolic heat production (e.g., shivering) or evaporative heat loss (e.g., sweating)].(1) The combination of behavior and sensible heat exchange permits a range of conditions that are deemed thermally comfortable, which is defined as the thermal comfort zone.(1) Notably, we spend the majority of our lives within the thermoneutral and thermal comfort zones. It is only when we are unable to stay within these zones that deleterious health and safety outcomes can occur (i.e., hypo- or hyperthermia). Oddly, although the thermoneutral zone and thermal preference (a concept similar to the thermal comfort zone) has been extensively studied in non-human animals, our understanding of human thermoregulation within the thermoneutral and thermal comfort zones remains rather crude.

  5. Evidence for β-adrenergic modulation of sweating during incremental exercise in habitually trained males.

    PubMed

    Amano, Tatsuro; Shitara, Yosuke; Fujii, Naoto; Inoue, Yoshimitsu; Kondo, Narihiko

    2017-07-01

    The aim of the present study was to determine the β-adrenergic contribution to sweating during incremental exercise in habitually trained males. Nine habitually trained and 11 untrained males performed incremental cycling until exhaustion (20 W/min). Bilateral forearm sweat rates (ventilated capsule) were measured at two skin sites that were transdermally administered via iontophoresis with either 1% propranolol (Propranolol, a nonselective β-adrenergic receptor antagonist) or saline (Control). The sweat rate was evaluated as a function of both relative (percentage of maximum workload) and absolute exercise intensities. The sweat rate at the Propranolol site was lower than the control during exercise at 80 (0.57 ± 0.21 and 0.45 ± 0.19 mg·cm -2 ·min -1 for Control and Propranolol, respectively) and 90% (0.74 ± 0.22 and 0.65 ± 0.17 mg·cm -2 ·min -1 , respectively) of maximum workload in trained males (all P < 0.05). By contrast, no between-site differences in sweat rates were observed in untrained counterparts (all P > 0.05). At the same absolute intensity, higher sweat rates on the control site were observed in trained males relative to the untrained during exercise at 160 (0.23 ± 0.20 and 0.04 ± 0.05 mg·cm -2 ·min -1 for trained and untrained, respectively) and 180 W (0.40 ± 0.20 and 0.13 ± 0.13 mg·cm -2 ·min -1 , respectively) (all P < 0.05), whereas this between-group difference was not observed at the Propranolol site (all P > 0.05). We show that the β-adrenergic mechanism does modulate sweating during exercise at a submaximal high relative intensity in habitually trained males. The β-adrenergic mechanism may in part contribute to the greater sweat production in habitually trained males than in untrained counterparts during exercise. NEW & NOTEWORTHY We demonstrated for the first time that the β-adrenergic mechanism does modulate sweating (i.e., β-adrenergic sweating) during exercise using a localized β-adrenoceptor blockade in humans in vivo. β-Adrenergic sweating was evident in habitually trained individuals during exercise at a submaximal high relative intensity (80-90% maximal work). This observation advances our understanding of human thermoregulation during exercise and of the mechanism that underlies sweat gland adaptation to habitual exercise training. Copyright © 2017 the American Physiological Society.

  6. Detection of Nanosilver Agents in Antibacterial Textiles

    NASA Astrophysics Data System (ADS)

    Xu, Chengtao; Zhao, Jie; Wu, Jianjian; Nie, Jinmei; Cui, Chengmin; Xie, Weibin; Zhang, Yan

    2018-01-01

    The analytical techniques are needed to detect the nanosilver in textiles in direct contact with skin. In this paper, in order to discuss the extraction of nanosilver on the surface of textiles by human skin, we demonstrate the capability of constant temperature oscillation extraction method followed by Inductively Coupled Plasma Spectroscopy (ICP). The sweat and deionized water were selected as extraction solvent simulating the contact process of human skin with textiles. The SEM and TEM analysis shows the existence of nanosilver in the fabric and aqueous extract. ICP analysis shows accurately when analysing silver amounts in the range of 0.05∼1.2 mg/L with r2 values of 0.9997. The percent recoveries of all fabrics were all lower than 44 %.The results shows that the developed method of simulating of human sweat extraction was not very effective. So the nanosilver might not be transferred to human body effectively from the fabric.

  7. Use of dew-point detection for quantitative measurement of sweating rate

    NASA Technical Reports Server (NTRS)

    Brengelmann, G. L.; Mckeag, M.; Rowell, L. B.

    1975-01-01

    A method of measuring sweat rate (SR) based on detection of dew point (DP) is proposed which has advantages that may be attractive to other laboratories concerned with recording SR from selected areas of skin. It is similar to other methods in that dry gas is passed through a capsule which isolates several square centimeters of skin surface. The difference is in the means of determining how much gaseous water is carried off in the effluent moist gas. The DP detector used is free of the drawbacks of previous devices. DP is obtained through the fundamental technique of determining the temperature at which condensate forms on a mirror. Variations in DP are tracked rapidly, and accurately (+ or - 0.8 C nominal, sensitivity + or - 0.05 C) over a wide range ( -40 C to +50 C) without measurable hysteresis. The detector asembly is rugged and readily opened for cleaning and inspection.

  8. High resolution imaging of latent fingerprints by localized corrosion on brass surfaces.

    PubMed

    Goddard, Alex J; Hillman, A Robert; Bond, John W

    2010-01-01

    The Atomic Force Microscope (AFM) is capable of imaging fingerprint ridges on polished brass substrates at an unprecedented level of detail. While exposure to elevated humidity at ambient or slightly raised temperatures does not change the image appreciably, subsequent brief heating in a flame results in complete loss of the sweat deposit and the appearance of pits and trenches. Localized elemental analysis (using EDAX, coupled with SEM imaging) shows the presence of the constituents of salt in the initial deposits. Together with water and atmospheric oxygen--and with thermal enhancement--these are capable of driving a surface corrosion process. This process is sufficiently localized that it has the potential to generate a durable negative topographical image of the fingerprint. AFM examination of surface regions between ridges revealed small deposits (probably microscopic "spatter" of sweat components or transferred particulates) that may ultimately limit the level of ridge detail analysis.

  9. Does anticipatory sweating occur prior to fluid consumption?

    PubMed

    Wing, David; McClintock, Rebecca; Plumlee, Deva; Rathke, Michelle; Burnett, Tim; Lyons, Bailey; Buono, Michael J

    2012-01-01

    The purpose of this study was to examine if anticipatory sweating occurs prior to fluid consumption in dehydrated subjects. It was hypothesized that there would first be an anticipatory response to the sight of water, and then with drinking, a second response caused by mechanical stimulation of oropharyngeal nerves. Dehydrated subjects (n=19) sat in a heat chamber for 30 minutes. At minute 15, a resistance hygrometer capsule was attached and sweat rate was measured every 3 seconds. At minute 35:00, a researcher entered the room with previously measured water (2 ml/kg euhydrated body weight). At minute 35:30, the subject was allowed to drink. Data collection continued for 5 minutes post consumption. As expected, 16 of the 19 subjects responded to oropharyngeal stimuli with increased sweat rate. However, the new finding was that a majority (12 of 19) also showed an anticipatory sweating response prior to fluid consumption. Subjects were divided into 4 groups based on the magnitude of the sweating response. Strong responders' (n=4) anticipatory response accounted for 50% or more of the total change in sweat rate. Moderate responders' (n=4) anticipatory response accounted for 20%-49%. Weak responders' (n=4) anticipatory response accounted for 6-20%. Finally, non-responders (n=7) showed no anticipatory response. Although previously noted anecdotally in the literature, the current study is the first to demonstrate that measurable anticipatory sweating occurs prior to fluid intake in dehydrated subjects in a significant percentage of the population. Such data suggests that cerebral input, like oropharyngeal stimulation, can temporarily remove the dehydration-induced inhibition of sweating.

  10. Does Replacing Sodium Excreted in Sweat Attenuate the Health Benefits of Physical Activity?

    PubMed

    Turner, Martin J; Avolio, Alberto P

    2016-08-01

    International guidelines suggest limiting sodium intake to 86-100 mmol/day, but average intake exceeds 150 mmol/day. Participants in physical activities are, however, advised to increase sodium intake before, during and after exercise to ensure euhydration, replace sodium lost in sweat, speed rehydration and maintain performance. A similar range of health benefits is attributable to exercise and to reduction in sodium intake, including reductions in blood pressure (BP) and the increase of BP with age, reduced risk of stroke and other cardiovascular diseases, and reduced risk of osteoporosis and dementia. Sweat typically contains 40-60 mmol/L of sodium, leading to approximately 20-90 mmol of sodium lost in one exercise session with sweat rates of 0.5-1.5 L/h. Reductions in sodium intake of 20-90 mmol/day have been associated with substantial health benefits. Homeostatic systems reduce sweat sodium as low as 3-10 mmol/L to prevent excessive sodium loss. "Salty sweaters" may be individuals with high sodium intake who perpetuate their "salty sweat" condition by continual replacement of sodium excreted in sweat. Studies of prolonged high intensity exercise in hot environments suggest that sodium supplementation is not necessary to prevent hyponatremia during exercise lasting up to 6 hr. We examine the novel hypothesis that sodium excreted in sweat during physical activity offsets a significant fraction of excess dietary sodium, and hence may contribute part of the health benefits of exercise. Replacing sodium lost in sweat during exercise may improve physical performance, but may attenuate the long-term health benefits of exercise.

  11. Effects of Immediate Telephone Follow-Up with Providers on Sweat Chloride Test Timing after Cystic Fibrosis Newborn Screening Identifies a Single Mutation

    PubMed Central

    La Pean, Alison; Farrell, Michael H.; Eskra, Kerry L.; Farrell, Philip M.

    2012-01-01

    Objectives To assess whether reporting “possible cystic fibrosis (CF)” newborn screening (NBS) results via fax plus simultaneous telephone contact with primary care providers (PCPs), versus fax alone, influenced three outcomes: getting a sweat chloride test, age at sweat chloride test, and sweat-testing before 8 weeks old. Study Design Retrospective cohort comparison of infants born in Wisconsin whose PCPs received telephone intervention (n=301), versus recent historical controls whose PCP did not (n=355). Intervention data were collected during a longitudinal research and quality improvement effort; de-identified comparison data were constructed from auxiliary NBS tracking information. Parametric and nonparametric statistical analyses tested for group differences. Results Most infants (92%) with “possible CF” NBS results whose PCPs lacked telephone intervention ultimately underwent sweat-testing, underlining efficacy for fax-only reporting. Telephone intervention was significantly associated with improvements in infants undergoing sweat-testing at both ≤6 and <8 weeks and a slight, but non-significant, 3.5-day reduction in infants’ age at sweat-testing. The effect of telephone intervention was greater for PCPs whose patients underwent sweat-testing at community-affiliated medical centers versus academic medical centers (p=0.008). Conclusion Reporting “possible CF” NBS results via fax plus simultaneous telephone follow-up with PCPs increases the number of infants who have sweat chloride tests before 8 weeks of age, when affected infants are more likely to receive full benefits of early diagnosis and treatment. PMID:23102590

  12. Sweat Gland Progenitors in Development, Homeostasis, and Wound Repair

    PubMed Central

    Lu, Catherine; Fuchs, Elaine

    2014-01-01

    The human body is covered with several million sweat glands. These tiny coiled tubular skin appendages produce the sweat that is our primary source of cooling and hydration of the skin. Numerous studies have been published on their morphology and physiology. Until recently, however, little was known about how glandular skin maintains homeostasis and repairs itself after tissue injury. Here, we provide a brief overview of sweat gland biology, including newly identified reservoirs of stem cells in glandular skin and their activation in response to different types of injuries. Finally, we discuss how the genetics and biology of glandular skin has advanced our knowledge of human disorders associated with altered sweat gland activity. PMID:24492848

  13. Multidimensional Raman spectroscopic signature of sweat and its potential application to forensic body fluid identification.

    PubMed

    Sikirzhytski, Vitali; Sikirzhytskaya, Aliaksandra; Lednev, Igor K

    2012-03-09

    This proof-of-concept study demonstrated the potential of Raman microspectroscopy for nondestructive identification of traces of sweat for forensic purposes. Advanced statistical analysis of Raman spectra revealed that dry sweat was intrinsically heterogeneous, and its biochemical composition varies significantly with the donor. As a result, no single Raman spectrum could adequately represent sweat traces. Instead, a multidimensional spectroscopic signature of sweat was built that allowed for the presentation of any single experimental spectrum as a linear combination of two fluorescent backgrounds and three Raman spectral components dominated by the contribution from lactate, lactic acid, urea and single amino acids. Copyright © 2011 Elsevier B.V. All rights reserved.

  14. A Low-Cost CMOS Programmable Temperature Switch

    PubMed Central

    Li, Yunlong; Wu, Nanjian

    2008-01-01

    A novel uncalibrated CMOS programmable temperature switch with high temperature accuracy is presented. Its threshold temperature Tth can be programmed by adjusting the ratios of width and length of the transistors. The operating principles of the temperature switch circuit is theoretically explained. A floating gate neural MOS circuit is designed to compensate automatically the threshold temperature Tth variation that results form the process tolerance. The switch circuit is implemented in a standard 0.35 μm CMOS process. The temperature switch can be programmed to perform the switch operation at 16 different threshold temperature Tths from 45—120°C with a 5°C increment. The measurement shows a good consistency in the threshold temperatures. The chip core area is 0.04 mm2 and power consumption is 3.1 μA at 3.3V power supply. The advantages of the temperature switch are low power consumption, the programmable threshold temperature and the controllable hysteresis. PMID:27879871

  15. Chemosignals of stress influence social judgments.

    PubMed

    Dalton, Pamela; Mauté, Christopher; Jaén, Cristina; Wilson, Tamika

    2013-01-01

    Human body odors have important communicative functions regarding genetic identity, immune fitness and general health, but an expanding body of research suggests they can also communicate information about an individual's emotional state. In the current study, we tested whether axillary odors obtained from women experiencing psychosocial stress could negatively influence personality judgments of warmth and competence made about other women depicted in video scenarios. 44 female donors provided three types of sweat samples: untreated exercise sweat, untreated stress sweat and treated stress sweat. After a 'washout' period, a commercial unscented anti-perspirant product was applied to the left axilla only to evaluate whether 'blocking' the stress signal would improve the social evaluations. A separate group of male and female evaluators (n = 120) rated the women in the videos while smelling one of the three types of sweat samples. Women in the video scenes were rated as being more stressed by both men and women when smelling the untreated vs. treated stress sweat. For men only, the women in the videos were rated as less confident, trustworthy and competent when smelling both the untreated stress and exercise sweat in contrast to the treated stress sweat. Women's social judgments were unaffected by sniffing the pads. The results have implications for influencing multiple types of professional and personal social interactions and impression management and extend our understanding of the social communicative function of body odors.

  16. A Proteomic Analysis of Eccrine Sweat: Implications for the Discovery of Schizophrenia Biomarker Proteins

    PubMed Central

    Raiszadeh, Michelle M.; Ross, Mark M.; Russo, Paul S.; Schaepper, Mary Ann H.; Zhou, Weidong; Deng, Jianghong; Ng, Daniel; Dickson, April; Dickson, Cindy; Strom, Monica; Osorio, Carolina; Soeprono, Thomas; Wulfkuhle, Julia D.; Kabbani, Nadine; Petricoin, Emanuel F.; Liotta, Lance A.; Kirsch, Wolff M.

    2012-01-01

    Liquid chromatography tandem mass spectrometry (LC-MS/MS) and multiple reaction monitoring mass spectrometry (MRM-MS) proteomics analyses were performed on eccrine sweat of healthy controls, and the results were compared with those from individuals diagnosed with schizophrenia (SZ). This is the first large scale study of the sweat proteome. First, we performed LC-MS/MS on pooled SZ samples and pooled control samples for global proteomics analysis. Results revealed a high abundance of diverse proteins and peptides in eccrine sweat. Most of the proteins identified from sweat samples were found to be different than the most abundant proteins from serum, which indicates that eccrine sweat is not simply a plasma transudate, and may thereby be a source of unique disease-associated biomolecules. A second independent set of patient and control sweat samples were analyzed by LC-MS/MS and spectral counting to determine qualitative protein differential abundances between the control and disease groups. Differential abundances of selected proteins, initially determined by spectral counting, were verified by MRM-MS analyses. Seventeen proteins showed a differential abundance of approximately two-fold or greater between the SZ pooled sample and the control pooled sample. This study demonstrates the utility of LC-MS/MS and MRM-MS as a viable strategy for the discovery and verification of potential sweat protein disease biomarkers. PMID:22256890

  17. Prolonged head-down tilt exposure reduces maximal cutaneous vasodilator and sweating capacity in humans

    NASA Technical Reports Server (NTRS)

    Crandall, C. G.; Shibasaki, M.; Wilson, T. E.; Cui, J.; Levine, B. D.

    2003-01-01

    Cutaneous vasodilation and sweat rate are reduced during a thermal challenge after simulated and actual microgravity exposure. The effects of microgravity exposure on cutaneous vasodilator capacity and on sweat gland function are unknown. The purpose of this study was to test the hypothesis that simulated microgravity exposure, using the 6 degrees head-down tilt (HDT) bed rest model, reduces maximal forearm cutaneous vascular conductance (FVC) and sweat gland function and that exercise during HDT preserves these responses. To test these hypotheses, 20 subjects were exposed to 14 days of strict HDT bed rest. Twelve of those subjects exercised (supine cycle ergometry) at 75% of pre-bed rest heart rate maximum for 90 min/day throughout HDT bed rest. Before and after HDT bed rest, maximal FVC was measured, via plethysmography, by heating the entire forearm to 42 degrees C for 45 min. Sweat gland function was assessed by administering 1 x 10(-6) to 2 M acetylcholine (9 doses) via intradermal microdialysis while simultaneously monitoring sweat rate over the microdialysis membranes. In the nonexercise group, maximal FVC and maximal stimulated sweat rate were significantly reduced after HDT bed rest. In contrast, these responses were unchanged in the exercise group. These data suggest that 14 days of simulated microgravity exposure, using the HDT bed rest model, reduces cutaneous vasodilator and sweating capacity, whereas aerobic exercise training during HDT bed rest preserves these responses.

  18. Regional variations in transepidermal water loss, eccrine sweat gland density, sweat secretion rates and electrolyte composition in resting and exercising humans

    PubMed Central

    2013-01-01

    Literature from the past 168 years has been filtered to provide a unified summary of the regional distribution of cutaneous water and electrolyte losses. The former occurs via transepidermal water vapour diffusion and secretion from the eccrine sweat glands. Daily insensible water losses for a standardised individual (surface area 1.8 m2) will be 0.6–2.3 L, with the hands (80–160 g.h−1) and feet (50–150 g.h−1) losing the most, the head and neck losing intermediate amounts (40–75 g.h−1) and all remaining sites losing 15–60 g.h−1. Whilst sweat gland densities vary widely across the skin surface, this same individual would possess some 2.03 million functional glands, with the highest density on the volar surfaces of the fingers (530 glands.cm−2) and the lowest on the upper lip (16 glands.cm−2). During passive heating that results in a resting whole-body sweat rate of approximately 0.4 L.min−1, the forehead (0.99 mg.cm−2.min−1), dorsal fingers (0.62 mg.cm−2.min−1) and upper back (0.59 mg.cm−2.min−1) would display the highest sweat flows, whilst the medial thighs and anterior legs will secrete the least (both 0.12 mg.cm−2.min−1). Since sweat glands selectively reabsorb electrolytes, the sodium and chloride composition of discharged sweat varies with secretion rate. Across whole-body sweat rates from 0.72 to 3.65 mg.cm−2.min−1, sodium losses of 26.5–49.7 mmol.L−1 could be expected, with the corresponding chloride loss being 26.8–36.7 mmol.L−1. Nevertheless, there can be threefold differences in electrolyte losses across skin regions. When exercising in the heat, local sweat rates increase dramatically, with regional glandular flows becoming more homogeneous. However, intra-regional evaporative potential remains proportional to each local surface area. Thus, there is little evidence that regional sudomotor variations reflect an hierarchical distribution of sweating either at rest or during exercise. PMID:23849497

  19. Variability of sweat chloride concentration in subjects with cystic fibrosis and G551D mutations.

    PubMed

    Vermeulen, F; Le Camus, C; Davies, J C; Bilton, D; Milenković, D; De Boeck, K

    2017-01-01

    Sweat chloride concentration, a biomarker of CFTR function, is an appropriate outcome parameter in clinical trials aimed at correcting the basic CF defect. Although there is consensus on a cut-off value to diagnose CF, we have only limited information on the within subject variability of sweat chloride over time. Such information would be useful for sample size calculations in clinical trials. Therefore, we retrospectively analyzed repeated sweat chloride values obtained in patients with G551D mutation(s) assigned to placebo in an ivacaftor interventional trial. In subjects with G551D at least 12years of age, a pilocarpine sweat test using Macroduct collector was taken on both arms at 8 time points over 48weeks. We explored 1062 pilocarpine sweat test values obtained in 78 placebo patients of the VX08-770-102 trial. Mean overall sweat chloride value (all patients, all tests, n=1062) was 100.8mmol/L (SD 12.7mmol/L). Using a multilevel mixed model, the between-subject standard deviation (SD) for sweat chloride was 8.9mmol/L (95% CI 7.4-10.6) and within-subject SD was 8.1mmol/L (95% CI 7.5-8.7). Limits of repeatability for repeat measurements were -19.7 to +21.6mmol/L using values from one arm, and -13.3 to 11.8mmol/L using mean of values obtained at 4 test occasions. Sample size calculations showed that the minimal treatment effect on sweat chloride concentration that can be demonstrated for a group of 5 patients is around 15mmol/L, using a cross-over design and combinations of 4 tests for each phase of the trial. Although the sweat test is considered a robust measure, sweat chloride measurements in patients with CF and a G551D mutation had an inherent biological variability that is higher than commonly considered. Further analyses of placebo group data are crucial to learn more about the natural variability of this outcome parameter. Copyright © 2016 European Cystic Fibrosis Society. Published by Elsevier B.V. All rights reserved.

  20. Factors affecting the energy consumption of two refrigerator-freezers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kao, J.Y.; Kelley, G.E.

    Two refrigerator-freezers, one with a top-mounted freezer and one with side-by-side doors, were tested in the laboratory to determine the sensitivity of their energy consumption to various operational factors. Room temperature, room humidity, door openings, and the setting of the anti-sweat heater switch were the factors examined. The results indicated that the room temperature and door openings had a significantly greater effect on energy consumption than the other two factors. More detailed tests were then performed under different room temperature and door-opening combinations. The relationship of door openings and the equivalent test room temperature was established. Finally, the effect onmore » energy of different temperature settings was studied. Test results are presented and discussed.« less

  1. Surface contamination artificially elevates initial sweat mineral concentrations

    USDA-ARS?s Scientific Manuscript database

    During exercise in the heat, sweat is initially concentrated in minerals, but serial sweat samples appear more dilute. Possible causes include reduced dermal mineral concentrations or flushing of surface contamination. PURPOSE: To simultaneously sample mineral concentrations in transdermal fluid (T...

  2. Thermoregulatory responses to exercise at a fixed rate of heat production are not altered by acute hypoxia.

    PubMed

    Coombs, Geoff B; Cramer, Matthew N; Ravanelli, Nicholas; Imbeault, Pascal; Jay, Ollie

    2017-05-01

    This study sought to assess the within-subject influence of acute hypoxia on exercise-induced changes in core temperature and sweating. Eight participants [1.75 (0.06) m, 70.2 (6.8) kg, 25 (4) yr, 54 (8) ml·kg -1 ·min -1 ] completed 45 min of cycling, once in normoxia (NORM; [Formula: see text] = 0.21) and twice in hypoxia (HYP1/HYP2; [Formula: see text]= 0.13) at 34.4(0.2)°C, 46(3)% RH. These trials were designed to elicit 1 ) two distinctly different %V̇o 2peak [NORM: 45 (8)% and HYP1: 62 (7)%] at the same heat production (H prod ) [NORM: 6.7 (0.6) W/kg and HYP1: 7.0 (0.5) W/kg]; and 2 ) the same %V̇o 2peak [NORM: 45 (8)% and HYP2: 48 (5)%] with different H prod [NORM: 6.7 (0.6) W/kg and HYP2: 5.5 (0.6) W/kg]. At a fixed %V̇o 2peak , changes in rectal temperature (ΔT re ) and changes in esophageal temperature (ΔT es ) were greater at end-exercise in NORM [ΔT re : 0.76 (0.19)°C; ΔT es : 0.64 (0.22)°C] compared with HYP2 [ΔT re : 0.56 (0.22)°C, P < 0.01; ΔT es : 0.42 (0.21)°C, P < 0.01]. As a result of a greater H prod ( P < 0.01) in normoxia, and therefore evaporative heat balance requirements, to maintain a similar %V̇o 2peak compared with hypoxia, mean local sweat rates (LSR) from the forearm, upper back, and forehead were greater (all P < 0.01) in NORM [1.10 (0.20) mg·cm -2 ·min -1 ] compared with HYP2 [0.71 (0.19) mg·cm -2 ·min -1 ]. However, at a fixed H prod , ΔT re [0.75 (0.24)°C; P = 0.77] and ΔT es [0.63 (0.29)°C; P = 0.69] were not different in HYP1, compared with NORM. Likewise, mean LSR [1.11 (0.20) mg·cm -2 ·min -1 ] was not different ( P = 0.84) in HYP1 compared with NORM. These data demonstrate, using a within-subjects design, that hypoxia does not independently influence thermoregulatory responses. Additionally, further evidence is provided to support that metabolic heat production, irrespective of %V̇o 2peak , determines changes in core temperature and sweating during exercise. NEW & NOTEWORTHY Using a within-subject design, hypoxia does not independently alter core temperature and sweating during exercise at a fixed rate of heat production. These findings also further contribute to the development of a methodological framework for assessing differences in thermoregulatory responses to exercise between various populations and individuals. Using the combined environmental stressors of heat and hypoxia we conclusively demonstrate that exercise intensity relative to aerobic capacity (i.e., %V̇o 2max ) does not influence changes in thermoregulatory responses. Copyright © 2017 the American Physiological Society.

  3. Thermoregulatory responses to exercise at a fixed rate of heat production are not altered by acute hypoxia

    PubMed Central

    Coombs, Geoff B.; Ravanelli, Nicholas; Imbeault, Pascal

    2017-01-01

    This study sought to assess the within-subject influence of acute hypoxia on exercise-induced changes in core temperature and sweating. Eight participants [1.75 (0.06) m, 70.2 (6.8) kg, 25 (4) yr, 54 (8) ml·kg−1·min−1] completed 45 min of cycling, once in normoxia (NORM; FIO2 = 0.21) and twice in hypoxia (HYP1/HYP2; FIO2= 0.13) at 34.4(0.2)°C, 46(3)% RH. These trials were designed to elicit 1) two distinctly different %V̇o2peak [NORM: 45 (8)% and HYP1: 62 (7)%] at the same heat production (Hprod) [NORM: 6.7 (0.6) W/kg and HYP1: 7.0 (0.5) W/kg]; and 2) the same %V̇o2peak [NORM: 45 (8)% and HYP2: 48 (5)%] with different Hprod [NORM: 6.7 (0.6) W/kg and HYP2: 5.5 (0.6) W/kg]. At a fixed %V̇o2peak, changes in rectal temperature (ΔTre) and changes in esophageal temperature (ΔTes) were greater at end-exercise in NORM [ΔTre: 0.76 (0.19)°C; ΔTes: 0.64 (0.22)°C] compared with HYP2 [ΔTre: 0.56 (0.22)°C, P < 0.01; ΔTes: 0.42 (0.21)°C, P < 0.01]. As a result of a greater Hprod (P < 0.01) in normoxia, and therefore evaporative heat balance requirements, to maintain a similar %V̇o2peak compared with hypoxia, mean local sweat rates (LSR) from the forearm, upper back, and forehead were greater (all P < 0.01) in NORM [1.10 (0.20) mg·cm−2·min−1] compared with HYP2 [0.71 (0.19) mg·cm−2·min−1]. However, at a fixed Hprod, ΔTre [0.75 (0.24)°C; P = 0.77] and ΔTes [0.63 (0.29)°C; P = 0.69] were not different in HYP1, compared with NORM. Likewise, mean LSR [1.11 (0.20) mg·cm−2·min−1] was not different (P = 0.84) in HYP1 compared with NORM. These data demonstrate, using a within-subjects design, that hypoxia does not independently influence thermoregulatory responses. Additionally, further evidence is provided to support that metabolic heat production, irrespective of %V̇o2peak, determines changes in core temperature and sweating during exercise. NEW & NOTEWORTHY Using a within-subject design, hypoxia does not independently alter core temperature and sweating during exercise at a fixed rate of heat production. These findings also further contribute to the development of a methodological framework for assessing differences in thermoregulatory responses to exercise between various populations and individuals. Using the combined environmental stressors of heat and hypoxia we conclusively demonstrate that exercise intensity relative to aerobic capacity (i.e., %V̇o2max) does not influence changes in thermoregulatory responses. PMID:28302708

  4. The Sweat Metabolome of Screen-Positive Cystic Fibrosis Infants: Revealing Mechanisms beyond Impaired Chloride Transport

    PubMed Central

    2017-01-01

    The sweat chloride test remains the gold standard for confirmatory diagnosis of cystic fibrosis (CF) in support of universal newborn screening programs. However, it provides ambiguous results for intermediate sweat chloride cases while not reflecting disease progression when classifying the complex CF disease spectrum given the pleiotropic effects of gene modifiers and environment. Herein we report the first characterization of the sweat metabolome from screen-positive CF infants and identify metabolites associated with disease status that complement sweat chloride testing. Pilocarpine-stimulated sweat specimens were collected independently from two CF clinics, including 50 unaffected infants (e.g., carriers) and 18 confirmed CF cases. Nontargeted metabolite profiling was performed using multisegment injection–capillary electrophoresis–mass spectrometry as a high throughput platform for analysis of polar/ionic metabolites in volume-restricted sweat samples. Amino acids, organic acids, amino acid derivatives, dipeptides, purine derivatives, and unknown exogenous compounds were identified in sweat when using high resolution tandem mass spectrometry, including metabolites associated with affected yet asymptomatic CF infants, such as asparagine and glutamine. Unexpectedly, a metabolite of pilocarpine, used to stimulate sweat secretion, pilocarpic acid, and a plasticizer metabolite from environmental exposure, mono(2-ethylhexyl)phthalic acid, were secreted in the sweat of CF infants at significantly lower concentrations relative to unaffected CF screen-positive controls. These results indicated a deficiency in human paraoxonase, an enzyme unrelated to mutations to the cystic fibrosis transmembrane conductance regulator (CFTR) and impaired chloride transport, which is a nonspecific arylesterase/lactonase known to mediate inflammation, bacterial biofilm formation, and recurrent lung infections in affected CF children later in life. This work sheds new light into the underlying mechanisms of CF pathophysiology as required for new advances in precision medicine of orphan diseases that benefit from early detection and intervention, including new molecular targets for therapeutic intervention. PMID:28852705

  5. Sweat conductivity: an accurate diagnostic test for cystic fibrosis?

    PubMed

    Mattar, Ana Claudia Veras; Leone, Claudio; Rodrigues, Joaquim Carlos; Adde, Fabíola Villac

    2014-09-01

    Sweat chloride test is the gold standard test for cystic fibrosis (CF) diagnosis. Sweat conductivity is widely used although still considered a screening test. This was a prospective, cross-sectional, diagnostic research conducted at the laboratory of the Instituto da Criança of the Hospital das Clínicas, São Paulo, Brazil. Sweat chloride (quantitative pilocarpine iontophoresis) and sweat conductivity tests were simultaneously performed in patients referred for a sweat test between March 2007 and October 2008. Conductivity and chloride cut-off values used to rule out or diagnose CF were <75 and ≥90 mmol/L and <60 and ≥60 mmol/L, respectively. The ROC curve method was used to calculate the sensitivity, specificity, positive (PPV) and negative predictive value (NPV), as well as the respective 95% confidence intervals and to calculate the area under the curve for both tests. The kappa coefficient was used to evaluate agreement between the tests. Both tests were performed in 738 children, and CF was ruled out in 714 subjects; the median sweat chloride and conductivity values were 11 and 25 mmol/L in these populations, respectively. Twenty-four patients who had received a diagnosis of CF presented median sweat chloride and conductivity values of 87 and 103 mmol/L, respectively. Conductivity values above 90 mmol/L had 83.3% sensitivity, 99.7% specificity, 90.9% PPV and 99.4% NPV to diagnose CF. The best conductivity cut-off value to exclude CF was <75 mmol/L. Good agreement was observed between the tests (kappa: 0.934). The sweat conductivity test yielded a high degree of diagnostic accuracy and it showed good agreement with sweat chloride. We suggest that it should play a role as a diagnostic test for CF in the near future. Copyright © 2014 European Cystic Fibrosis Society. Published by Elsevier B.V. All rights reserved.

  6. The Sweat Metabolome of Screen-Positive Cystic Fibrosis Infants: Revealing Mechanisms beyond Impaired Chloride Transport.

    PubMed

    Macedo, Adriana N; Mathiaparanam, Stellena; Brick, Lauren; Keenan, Katherine; Gonska, Tanja; Pedder, Linda; Hill, Stephen; Britz-McKibbin, Philip

    2017-08-23

    The sweat chloride test remains the gold standard for confirmatory diagnosis of cystic fibrosis (CF) in support of universal newborn screening programs. However, it provides ambiguous results for intermediate sweat chloride cases while not reflecting disease progression when classifying the complex CF disease spectrum given the pleiotropic effects of gene modifiers and environment. Herein we report the first characterization of the sweat metabolome from screen-positive CF infants and identify metabolites associated with disease status that complement sweat chloride testing. Pilocarpine-stimulated sweat specimens were collected independently from two CF clinics, including 50 unaffected infants (e.g., carriers) and 18 confirmed CF cases. Nontargeted metabolite profiling was performed using multisegment injection-capillary electrophoresis-mass spectrometry as a high throughput platform for analysis of polar/ionic metabolites in volume-restricted sweat samples. Amino acids, organic acids, amino acid derivatives, dipeptides, purine derivatives, and unknown exogenous compounds were identified in sweat when using high resolution tandem mass spectrometry, including metabolites associated with affected yet asymptomatic CF infants, such as asparagine and glutamine. Unexpectedly, a metabolite of pilocarpine, used to stimulate sweat secretion, pilocarpic acid, and a plasticizer metabolite from environmental exposure, mono(2-ethylhexyl)phthalic acid, were secreted in the sweat of CF infants at significantly lower concentrations relative to unaffected CF screen-positive controls. These results indicated a deficiency in human paraoxonase, an enzyme unrelated to mutations to the cystic fibrosis transmembrane conductance regulator (CFTR) and impaired chloride transport, which is a nonspecific arylesterase/lactonase known to mediate inflammation, bacterial biofilm formation, and recurrent lung infections in affected CF children later in life. This work sheds new light into the underlying mechanisms of CF pathophysiology as required for new advances in precision medicine of orphan diseases that benefit from early detection and intervention, including new molecular targets for therapeutic intervention.

  7. Human Excretion of Bisphenol A: Blood, Urine, and Sweat (BUS) Study

    PubMed Central

    Genuis, Stephen J.; Beesoon, Sanjay; Birkholz, Detlef; Lobo, Rebecca A.

    2012-01-01

    Background. Bisphenol A (BPA) is an ubiquitous chemical contaminant that has recently been associated with adverse effects on human health. There is incomplete understanding of BPA toxicokinetics, and there are no established interventions to eliminate this compound from the human body. Using 20 study participants, this study was designed to assess the relative concentration of BPA in three body fluids—blood, urine, and sweat—and to determine whether induced sweating may be a therapeutic intervention with potential to facilitate elimination of this compound. Methods. Blood, urine, and sweat were collected from 20 individuals (10 healthy participants and 10 participants with assorted health problems) and analyzed for various environmental toxicants including BPA. Results. BPA was found to differing degrees in each of blood, urine, and sweat. In 16 of 20 participants, BPA was identified in sweat, even in some individuals with no BPA detected in their serum or urine samples. Conclusions. Biomonitoring of BPA through blood and/or urine testing may underestimate the total body burden of this potential toxicant. Sweat analysis should be considered as an additional method for monitoring bioaccumulation of BPA in humans. Induced sweating appears to be a potential method for elimination of BPA. PMID:22253637

  8. Sweat lipid mediator profiling: a noninvasive approach for cutaneous research[S

    PubMed Central

    Hassoun, Lauren A.; Foolad, Negar; Pedersen, Theresa L.; Sivamani, Raja K.; Newman, John W.

    2017-01-01

    Recent advances in analytical and sweat collection techniques provide new opportunities to identify noninvasive biomarkers for the study of skin inflammation and repair. This study aims to characterize the lipid mediator profile including oxygenated lipids, endocannabinoids, and ceramides/sphingoid bases in sweat and identify differences in these profiles between sweat collected from nonlesional sites on the unflared volar forearm of subjects with and without atopic dermatitis (AD). Adapting routine procedures developed for plasma analysis, over 100 lipid mediators were profiled using LC-MS/MS and 58 lipid mediators were detected in sweat. Lipid mediator concentrations were not affected by sampling or storage conditions. Increases in concentrations of C30–C40 [NS] and [NdS] ceramides, and C18:1 sphingosine, were observed in the sweat of study participants with AD despite no differences being observed in transepidermal water loss between study groups, and this effect was strongest in men (P < 0.05, one-way ANOVA with Tukey’s post hoc HSD). No differences in oxylipins and endocannabinoids were observed between study groups. Sweat mediator profiling may therefore provide a noninvasive diagnostic for AD prior to the presentation of clinical signs. PMID:27875258

  9. Sweat lipid mediator profiling: a noninvasive approach for cutaneous research.

    PubMed

    Agrawal, Karan; Hassoun, Lauren A; Foolad, Negar; Pedersen, Theresa L; Sivamani, Raja K; Newman, John W

    2017-01-01

    Recent advances in analytical and sweat collection techniques provide new opportunities to identify noninvasive biomarkers for the study of skin inflammation and repair. This study aims to characterize the lipid mediator profile including oxygenated lipids, endocannabinoids, and ceramides/sphingoid bases in sweat and identify differences in these profiles between sweat collected from nonlesional sites on the unflared volar forearm of subjects with and without atopic dermatitis (AD). Adapting routine procedures developed for plasma analysis, over 100 lipid mediators were profiled using LC-MS/MS and 58 lipid mediators were detected in sweat. Lipid mediator concentrations were not affected by sampling or storage conditions. Increases in concentrations of C30-C40 [NS] and [NdS] ceramides, and C18:1 sphingosine, were observed in the sweat of study participants with AD despite no differences being observed in transepidermal water loss between study groups, and this effect was strongest in men (P < 0.05, one-way ANOVA with Tukey's post hoc HSD). No differences in oxylipins and endocannabinoids were observed between study groups. Sweat mediator profiling may therefore provide a noninvasive diagnostic for AD prior to the presentation of clinical signs.

  10. Cells in 3D-reconstitutued eccrine sweat gland cell spheroids differentiate into gross cystic disease fluid protein 15-expressing dark secretory cells and carbonic anhydrase II-expressing clear secretory cells.

    PubMed

    Li, Haihong; Chen, Liyun; Zhang, Mingjun; Zhang, Bingna

    2017-07-01

    Secretory coils of eccrine sweat glands are composed of myoepithelial cells, dark secretory cells and clear secretory cells. The two types of cells play important roles in sweat secretion. In our previous study, we demonstrated that the 3D-reconstituted eccrine sweat gland cell spheroids differentiate into secretory coil-like structures. However, whether the secretory coil-like structures further differentiate into dark secretory cells and clear secretory cells were is still unknown. In this study, we detected the differentiation of clear and dark secretory cells in the 3D-reconstituted eccrine sweat gland cell spheroids using the dark secretory cell-specific marker, GCDFP-15, and clear secretory cell-specific marker, CAII by immunofluorescence staining. Results showed that there were both GCDFP-15- and CAII-expressing cells in 12-week-old 3D spheroids, similar to native eccrine sweat glands, indicating that the spheroids possess a cellular structure capable of sweat secretion. We conclude that the 12-week 3D spheroids may have secretory capability. Copyright © 2017 Elsevier GmbH. All rights reserved.

  11. A Soft, Wearable Microfluidic Device for the Capture, Storage, and Colorimetric Sensing of Sweat

    PubMed Central

    Koh, Ahyeon; Kang, Daeshik; Xue, Yeguang; Lee, Seungmin; Pielak, Rafal M.; Kim, Jeonghyun; Hwang, Taehwan; Min, Seunghwan; Banks, Anthony; Bastien, Philippe; Manco, Megan C.; Wang, Liang; Ammann, Kaitlyn R.; Jang, Kyung-In; Won, Phillip; Han, Seungyong; Ghaffari, Roozbeh; Paik, Ungyu; Slepian, Marvin J.; Balooch, Guive; Huang, Yonggang; Rogers, John A.

    2017-01-01

    Capabilities in health monitoring via capture and quantitative chemical analysis of sweat could complement, or potentially obviate the need for, approaches based on sporadic assessment of blood samples. Established sweat monitoring technologies use simple fabric swatches and are limited to basic analysis in controlled laboratory or hospital settings. We present a collection of materials and device designs for soft, flexible and stretchable microfluidic systems, including embodiments that integrate wireless communication electronics, which can intimately and robustly bond to the surface of skin without chemical and mechanical irritation. This integration defines access points for a small set of sweat glands such that perspiration spontaneously initiates routing of sweat through a microfluidic network and set of reservoirs. Embedded chemical analyses respond in colorimetric fashion to markers such as chloride and hydronium ions, glucose and lactate. Wireless interfaces to digital image capture hardware serve as a means for quantitation. Human studies demonstrated the functionality of this microfluidic device during fitness cycling in a controlled environment and during long-distance bicycle racing in arid, outdoor conditions. The results include quantitative values for sweat rate, total sweat loss, pH and concentration of both chloride and lactate. PMID:27881826

  12. Human eccrine sweat gland cells turn into melanin-uptaking keratinocytes in dermo-epidermal skin substitutes.

    PubMed

    Böttcher-Haberzeth, Sophie; Biedermann, Thomas; Pontiggia, Luca; Braziulis, Erik; Schiestl, Clemens; Hendriks, Bart; Eichhoff, Ossia M; Widmer, Daniel S; Meuli-Simmen, Claudia; Meuli, Martin; Reichmann, Ernst

    2013-02-01

    Recently, Biedermann et al. (2010) have demonstrated that human eccrine sweat gland cells can develop a multilayered epidermis. The question still remains whether these cells can fulfill exclusive and very specific functional properties of epidermal keratinocytes, such as the incorporation of melanin, a feature absent in sweat gland cells. We added human melanocytes to eccrine sweat gland cells to let them develop into an epidermal analog in vivo. The interaction between melanocytes and sweat gland-derived keratinocytes was investigated. The following results were gained: (1) macroscopically, a pigmentation of the substitutes was seen 2-3 weeks after transplantation; (2) we confirmed the development of a multilayered, stratified epidermis with melanocytes distributed evenly throughout the basal layer; (3) melanocytic dendrites projected to suprabasal layers; and (4) melanin was observed to be integrated into former eccrine sweat gland cells. These skin substitutes were similar or equal to skin substitutes cultured from human epidermal keratinocytes. The only differences observed were a delay in pigmentation and less melanin uptake. These data suggest that eccrine sweat gland cells can form a functional epidermal melanin unit, thereby providing striking evidence that they can assume one of the most characteristic keratinocyte properties.

  13. Hot Flashes and Night Sweats (PDQ®)—Patient Version

    Cancer.gov

    Hot flashes and night sweats can be a side effect of cancer or its treatment and can occur in both women and men. Learn more about hot flashes and night sweats and ways to treat them in this expert-reviewed summary.

  14. 7 CFR 29.3065 - Sweating.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 2 2013-01-01 2013-01-01 false Sweating. 29.3065 Section 29.3065 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... Sweating. The condition of tobacco in the process of fermentation. [24 FR 8771, Oct. 29, 1959. Redesignated...

  15. 7 CFR 29.6042 - Sweated.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 2 2012-01-01 2012-01-01 false Sweated. 29.6042 Section 29.6042 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... INSPECTION Standards Definitions § 29.6042 Sweated. The condition of tobacco which has passed through one or...

  16. 7 CFR 29.6042 - Sweated.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 2 2011-01-01 2011-01-01 false Sweated. 29.6042 Section 29.6042 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... INSPECTION Standards Definitions § 29.6042 Sweated. The condition of tobacco which has passed through one or...

  17. 7 CFR 29.2306 - Sweated.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 2 2011-01-01 2011-01-01 false Sweated. 29.2306 Section 29.2306 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... Sweated. The condition of tobacco which has passed through one or more fermentations natural to tobacco...

  18. 7 CFR 29.6042 - Sweated.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Sweated. 29.6042 Section 29.6042 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... INSPECTION Standards Definitions § 29.6042 Sweated. The condition of tobacco which has passed through one or...

  19. 7 CFR 29.2307 - Sweating.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Sweating. 29.2307 Section 29.2307 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... Sweating. The condition of tobacco in the process of fermentation. [37 FR 13521, July 11, 1972...

  20. 7 CFR 29.3065 - Sweating.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 2 2014-01-01 2014-01-01 false Sweating. 29.3065 Section 29.3065 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... Sweating. The condition of tobacco in the process of fermentation. [24 FR 8771, Oct. 29, 1959. Redesignated...

  1. 7 CFR 29.2307 - Sweating.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 2 2013-01-01 2013-01-01 false Sweating. 29.2307 Section 29.2307 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... Sweating. The condition of tobacco in the process of fermentation. [37 FR 13521, July 11, 1972...

  2. 7 CFR 29.3065 - Sweating.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Sweating. 29.3065 Section 29.3065 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... Sweating. The condition of tobacco in the process of fermentation. [24 FR 8771, Oct. 29, 1959. Redesignated...

  3. 7 CFR 29.2307 - Sweating.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 2 2014-01-01 2014-01-01 false Sweating. 29.2307 Section 29.2307 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... Sweating. The condition of tobacco in the process of fermentation. [37 FR 13521, July 11, 1972...

  4. 7 CFR 29.2307 - Sweating.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 2 2012-01-01 2012-01-01 false Sweating. 29.2307 Section 29.2307 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... Sweating. The condition of tobacco in the process of fermentation. [37 FR 13521, July 11, 1972...

  5. 7 CFR 29.3064 - Sweated.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 2 2014-01-01 2014-01-01 false Sweated. 29.3064 Section 29.3064 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... Sweated. The condition of tobacco which has passed through one or more fermentations natural to tobacco...

  6. 7 CFR 29.3064 - Sweated.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 2 2012-01-01 2012-01-01 false Sweated. 29.3064 Section 29.3064 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... Sweated. The condition of tobacco which has passed through one or more fermentations natural to tobacco...

  7. 7 CFR 29.6042 - Sweated.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 2 2014-01-01 2014-01-01 false Sweated. 29.6042 Section 29.6042 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... INSPECTION Standards Definitions § 29.6042 Sweated. The condition of tobacco which has passed through one or...

  8. 7 CFR 29.2306 - Sweated.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Sweated. 29.2306 Section 29.2306 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... Sweated. The condition of tobacco which has passed through one or more fermentations natural to tobacco...

  9. 7 CFR 29.3065 - Sweating.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 2 2011-01-01 2011-01-01 false Sweating. 29.3065 Section 29.3065 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... Sweating. The condition of tobacco in the process of fermentation. [24 FR 8771, Oct. 29, 1959. Redesignated...

  10. 7 CFR 29.2306 - Sweated.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 2 2013-01-01 2013-01-01 false Sweated. 29.2306 Section 29.2306 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... Sweated. The condition of tobacco which has passed through one or more fermentations natural to tobacco...

  11. 7 CFR 29.2306 - Sweated.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 2 2012-01-01 2012-01-01 false Sweated. 29.2306 Section 29.2306 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... Sweated. The condition of tobacco which has passed through one or more fermentations natural to tobacco...

  12. 7 CFR 29.3065 - Sweating.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 2 2012-01-01 2012-01-01 false Sweating. 29.3065 Section 29.3065 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... Sweating. The condition of tobacco in the process of fermentation. [24 FR 8771, Oct. 29, 1959. Redesignated...

  13. 7 CFR 29.3064 - Sweated.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 2 2011-01-01 2011-01-01 false Sweated. 29.3064 Section 29.3064 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... Sweated. The condition of tobacco which has passed through one or more fermentations natural to tobacco...

  14. 7 CFR 29.2306 - Sweated.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 2 2014-01-01 2014-01-01 false Sweated. 29.2306 Section 29.2306 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... Sweated. The condition of tobacco which has passed through one or more fermentations natural to tobacco...

  15. 7 CFR 29.6042 - Sweated.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 2 2013-01-01 2013-01-01 false Sweated. 29.6042 Section 29.6042 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... INSPECTION Standards Definitions § 29.6042 Sweated. The condition of tobacco which has passed through one or...

  16. 7 CFR 29.3064 - Sweated.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Sweated. 29.3064 Section 29.3064 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... Sweated. The condition of tobacco which has passed through one or more fermentations natural to tobacco...

  17. 7 CFR 29.2307 - Sweating.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 2 2011-01-01 2011-01-01 false Sweating. 29.2307 Section 29.2307 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... Sweating. The condition of tobacco in the process of fermentation. [37 FR 13521, July 11, 1972...

  18. 7 CFR 29.3064 - Sweated.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 2 2013-01-01 2013-01-01 false Sweated. 29.3064 Section 29.3064 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... Sweated. The condition of tobacco which has passed through one or more fermentations natural to tobacco...

  19. Sweating

    MedlinePlus Videos and Cool Tools

    ... half million eccrine sweat glands all over the body. They lie deep in the skin and are connected to the surface by coiled tubes called ducts. Sweat (perspiration) is a liquid mixture made up of 99% water and 1% salt and fat. Up to a quart of liquid a day ...

  20. Imaging calcium carbonate distribution in human sweat pore in vivo using nonlinear microscopy

    NASA Astrophysics Data System (ADS)

    Chen, Xueqin; Gasecka, Alicja; Formanek, Florian; Galey, Jean-Baptiste; Rigneault, Hervé

    2015-03-01

    Nonlinear microscopies, including two-photon excited autofluorescence (TPEF) and coherent anti-Stokes Raman scattering (CARS), were used to study individual human sweat pore morphology and topically applied antiperspirant salt penetration inside sweat pore, in vivo on human palms. Sweat pore inner morphology in vivo was imaged up to the depth of 100 μm by TPEF microscopy. The 3D penetration and distribution of "in situ calcium carbonate" (isCC), an antiperspirant salt model, was investigated using CARS microscopy.

  1. The physiological responses to Bikram yoga in novice and experienced practitioners.

    PubMed

    Pate, Jessica L; Buono, Michael J

    2014-01-01

    Bikram yoga has gained a large following, possibly because of widespread claims boasting energy expenditure of up to 1000 calories per session. However, these claims are unfounded because no scientific study has investigated the metabolic response to a complete, standardized Bikram yoga class. This study intends to determine energy expenditure, heart rate, and sweat rate in novice and experienced practitioners from a standardized Bikram yoga class. Data were collected in the environmental chamber of the Exercise Physiology Laboratory at San Diego State University in California, USA. Male (n = 5) and female (n = 19) participants between the ages of 18 and 57 y were recruited through flyers in yoga studios throughout San Diego. Participants were classified as experienced or novice practitioners, having completed ≥20 or <20 sessions, respectively. Participants were guided through a standardized 90-min yoga class performed in a hot environment using Bikram's Standard Beginning Dialogue, while expired gas was collected and heart rate was recorded. Energy expenditure, calculated via oxygen uptake, and heart rate were determined for each posture and transition period. In addition, sweat rate and core temperature were recorded for each participant. Mean (±SD) relative VO2 for the entire 90-min session was 9.5 ± 1.9 mL × kg-1 × min-1, ranging from 6.0 to 12.9 mL × kg-1 × min-1. Mean absolute energy expenditure was 286 ± 72 kcals, ranging from 179 to 478 kcals. Independent sample t tests revealed significant differences (P < .05) in relative energy expenditure, heart rate, ending core temperature, and sweat rate between experience levels. Mean relative energy expenditure was 3.7 ± 0.5 kcal/kg in novice practitioners and 4.7 ± 0.8 kcal/kg in experienced practitioners. Percentage of predicted maximum heart rate and sweat rate were 72.3% ± 10.6% and 0.6 ± 0.2 kg/h in novice practitioners and 86.4% ± 5.2% and 1.1 ± 0.5 kg/h in experienced participants. All postures were classified as light-to-moderate intensity according to the American College of Sports Medicine (ACSM) standards. Bikram yoga meets requirements for exercise of light-to-moderate intensity and, theoretically, could be used for weight maintenance or weight loss if practiced several times per week.

  2. Effect of Exercise-induced Sweating on facial sebum, stratum corneum hydration, and skin surface pH in normal population.

    PubMed

    Wang, Siyu; Zhang, Guirong; Meng, Huimin; Li, Li

    2013-02-01

    Evidence demonstrated that sweat was an important factor affecting skin physiological properties. We intended to assess the effects of exercise-induced sweating on the sebum, stratum corneum (SC) hydration and skin surface pH of facial skin. 102 subjects (aged 5-60, divided into five groups) were enrolled to be measured by a combination device called 'Derma Unit SSC3' in their frontal and zygomatic regions when they were in a resting state (RS), at the beginning of sweating (BS), during excessive sweating (ES) and an hour after sweating (AS), respectively. Compared to the RS, SC hydration in both regions increased at the BS or during ES, and sebum increased at the BS but lower during ES. Compared to during ES, Sebum increased in AS but lower than RS. Compared to the RS, pH decreased in both regions at the BS in the majority of groups, and increased in frontal region during ES and in zygomatic region in the AS. There was an increase in pH in both regions during ES in the majority of groups compared to the BS, but a decrease in the AS compared to during ES. The study implies that even in summer, after we sweat excessively, lipid products should be applied locally in order to maintain stability of the barrier function of the SC. The study suggests that after a short term(1 h or less) of self adjustment, excessive sweat from moderate exercise will not impair the primary acidic surface pH of the facial skin. Exercise-induced sweating significantly affected the skin physiological properties of facial region. © 2012 John Wiley & Sons A/S.

  3. Intra-individual biological variation in sweat chloride concentrations in CF, CFTR dysfunction, and healthy pediatric subjects.

    PubMed

    Cirilli, Natalia; Raia, Valeria; Rocco, Ilaria; De Gregorio, Fabiola; Tosco, Antonella; Salvadori, Laura; Sepe, Angela Ornella; Buzzetti, Roberto; Minicuci, Nadia; Castaldo, Giuseppe

    2018-04-02

    The sweat test is one of the main diagnostic tools used in newborn screening programs and as a confirmatory test, in case of suspect of Cystic Fibrosis (CF). Since sweat chloride (Cl) concentration is also considered an appropriate parameter to explore the efficacy of CFTR modulators in clinical trials, it is crucial to evaluate the biological variability of this test in healthy and pathological conditions. The aim of this pilot study was to determine the intra-individual biological variability of sweat Cl, both in healthy individuals and CF patients and to assess its correlation with diet, season, and menstrual cycle. Thirty-five out of 36 selected subjects (6-18 years) were enrolled by 2 CF care centers and assigned to 3 cohorts: CF, CFTR-related disorder (CFTR-RD) and healthy volunteers. Each participant was subjected to eight sweat tests in different conditions and time of the year. Data were analyzed using linear mixed effects models for repeated measures, taking also into account intra-individual correlations. We observed a high intra-individual variability of sweat Cl, with the lowest mean CV% values among CF patients (20.21 in CF, 29.74 in CFTR-RD, and 31.15 in healthy subjects). Gender and diet had no influence on sweat Cl variability, nor had pubertal age and menstrual phase. Results of this pilot study confirmed that sweat Cl variability is high in CF patients, although non-CF individuals displayed even higher mean CV% values. Season significantly influenced sweat test values only in CF patients, likely due to changes in their hydration status. © 2018 Wiley Periodicals, Inc.

  4. Effect of Sweating on Insulation of Footwear.

    PubMed

    Kuklane, Kalev; Holmér, Ingvar

    1998-01-01

    The study aimed to find out the influence of sweating on footwear insulation with a thermal foot model. Simultaneously, the influence of applied weight (35 kg), sock, and steel toe cap were studied. Water to 3 sweat glands was supplied with a pump at the rate of 10 g/hr in total. Four models of boots with steel toe caps were tested. The same models were manufactured also without steel toe. Sweating reduced footwear insulation 19-25% (30-37% in toes). During static conditions, only a minimal amount of sweat evaporated from boots. Weight affected sole insulation: Reduction depended on compressibility of sole material. The influence of steel toe varied with insulation. The method of thermal foot model appears to be a practical tool for footwear evaluation.

  5. 7 CFR 29.2558 - Sweated.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 2 2013-01-01 2013-01-01 false Sweated. 29.2558 Section 29.2558 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing...-Cured Tobacco (u.s. Types 22, 23, and Foreign Type 96) § 29.2558 Sweated. The condition of tobacco...

  6. 7 CFR 29.3553 - Sweated.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 2 2014-01-01 2014-01-01 false Sweated. 29.3553 Section 29.3553 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... Type 95) § 29.3553 Sweated. The condition of tobacco which has passed through one or more fermentations...

  7. 7 CFR 29.3554 - Sweating.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 2 2012-01-01 2012-01-01 false Sweating. 29.3554 Section 29.3554 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... Type 95) § 29.3554 Sweating. The condition of tobacco in the process of fermentation. [30 FR 9207, July...

  8. 7 CFR 29.2558 - Sweated.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Sweated. 29.2558 Section 29.2558 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing...-Cured Tobacco (u.s. Types 22, 23, and Foreign Type 96) § 29.2558 Sweated. The condition of tobacco...

  9. 7 CFR 29.1065 - Sweating.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 2 2012-01-01 2012-01-01 false Sweating. 29.1065 Section 29.1065 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... Type 92) § 29.1065 Sweating. The condition of tobacco in the process of fermentation. [42 FR 21092, Apr...

  10. 7 CFR 29.1065 - Sweating.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 2 2014-01-01 2014-01-01 false Sweating. 29.1065 Section 29.1065 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... Type 92) § 29.1065 Sweating. The condition of tobacco in the process of fermentation. [42 FR 21092, Apr...

  11. 7 CFR 29.2558 - Sweated.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 2 2014-01-01 2014-01-01 false Sweated. 29.2558 Section 29.2558 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing...-Cured Tobacco (u.s. Types 22, 23, and Foreign Type 96) § 29.2558 Sweated. The condition of tobacco...

  12. 7 CFR 29.3553 - Sweated.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 2 2011-01-01 2011-01-01 false Sweated. 29.3553 Section 29.3553 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... Type 95) § 29.3553 Sweated. The condition of tobacco which has passed through one or more fermentations...

  13. 7 CFR 29.3554 - Sweating.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Sweating. 29.3554 Section 29.3554 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... Type 95) § 29.3554 Sweating. The condition of tobacco in the process of fermentation. [30 FR 9207, July...

  14. 7 CFR 29.1065 - Sweating.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Sweating. 29.1065 Section 29.1065 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... Type 92) § 29.1065 Sweating. The condition of tobacco in the process of fermentation. [42 FR 21092, Apr...

  15. 7 CFR 29.1064 - Sweated.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 2 2013-01-01 2013-01-01 false Sweated. 29.1064 Section 29.1064 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... Type 92) § 29.1064 Sweated. The condition of tobacco which has passed through one or more fermentations...

  16. 7 CFR 29.2558 - Sweated.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 2 2011-01-01 2011-01-01 false Sweated. 29.2558 Section 29.2558 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing...-Cured Tobacco (u.s. Types 22, 23, and Foreign Type 96) § 29.2558 Sweated. The condition of tobacco...

  17. 7 CFR 29.2558 - Sweated.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 2 2012-01-01 2012-01-01 false Sweated. 29.2558 Section 29.2558 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing...-Cured Tobacco (u.s. Types 22, 23, and Foreign Type 96) § 29.2558 Sweated. The condition of tobacco...

  18. 7 CFR 29.1065 - Sweating.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 2 2013-01-01 2013-01-01 false Sweating. 29.1065 Section 29.1065 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... Type 92) § 29.1065 Sweating. The condition of tobacco in the process of fermentation. [42 FR 21092, Apr...

  19. 7 CFR 29.3554 - Sweating.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 2 2011-01-01 2011-01-01 false Sweating. 29.3554 Section 29.3554 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... Type 95) § 29.3554 Sweating. The condition of tobacco in the process of fermentation. [30 FR 9207, July...

  20. 7 CFR 29.1064 - Sweated.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 2 2012-01-01 2012-01-01 false Sweated. 29.1064 Section 29.1064 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... Type 92) § 29.1064 Sweated. The condition of tobacco which has passed through one or more fermentations...

  1. 7 CFR 29.1065 - Sweating.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 2 2011-01-01 2011-01-01 false Sweating. 29.1065 Section 29.1065 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... Type 92) § 29.1065 Sweating. The condition of tobacco in the process of fermentation. [42 FR 21092, Apr...

  2. 7 CFR 29.1064 - Sweated.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 2 2014-01-01 2014-01-01 false Sweated. 29.1064 Section 29.1064 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... Type 92) § 29.1064 Sweated. The condition of tobacco which has passed through one or more fermentations...

  3. 7 CFR 29.3553 - Sweated.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Sweated. 29.3553 Section 29.3553 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... Type 95) § 29.3553 Sweated. The condition of tobacco which has passed through one or more fermentations...

  4. Relationship between osmotic pressure of the blood and secretion of sweat

    NASA Technical Reports Server (NTRS)

    Montuori, A.

    1978-01-01

    Experiments with cats show that the thermic secretion of sweat represents a specific case of a general law: The central nervous apparatus that controls the secretion of sweat begins to function when the osmotic pressure of the blood drops below normal.

  5. 7 CFR 29.3553 - Sweated.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 2 2012-01-01 2012-01-01 false Sweated. 29.3553 Section 29.3553 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... Type 95) § 29.3553 Sweated. The condition of tobacco which has passed through one or more fermentations...

  6. 7 CFR 29.1064 - Sweated.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 2 2011-01-01 2011-01-01 false Sweated. 29.1064 Section 29.1064 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... Type 92) § 29.1064 Sweated. The condition of tobacco which has passed through one or more fermentations...

  7. 7 CFR 29.3553 - Sweated.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 2 2013-01-01 2013-01-01 false Sweated. 29.3553 Section 29.3553 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... Type 95) § 29.3553 Sweated. The condition of tobacco which has passed through one or more fermentations...

  8. 7 CFR 29.1064 - Sweated.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Sweated. 29.1064 Section 29.1064 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... Type 92) § 29.1064 Sweated. The condition of tobacco which has passed through one or more fermentations...

  9. 7 CFR 29.3554 - Sweating.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 2 2013-01-01 2013-01-01 false Sweating. 29.3554 Section 29.3554 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... Type 95) § 29.3554 Sweating. The condition of tobacco in the process of fermentation. [30 FR 9207, July...

  10. 7 CFR 29.3554 - Sweating.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 2 2014-01-01 2014-01-01 false Sweating. 29.3554 Section 29.3554 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... Type 95) § 29.3554 Sweating. The condition of tobacco in the process of fermentation. [30 FR 9207, July...

  11. Effect of micro mist sauna bathing on thermoregulatory and circulatory functions and thermal sensation in humans

    NASA Astrophysics Data System (ADS)

    Iwase, Satoshi; Kawahara, Yuko; Nishimura, Naoki; Sugenoya, Junichi

    2016-05-01

    To examine the effects of micro mist sauna bathing, produced by water crushing method, we exposed ten male subjects to five cases of micro mist sauna, namely (1) room temperature (RT) 38 °C with 100 % (actually 91 %) relative humidity (RH), (2) RT 41.5 °C with 80 % (actually 81 %) RH, (3) RT 41.5 °C with 100 % (actually 96 %) RH, (4) RT 45.0 °C with 64 % (actually 61 %) RH, and (5) RT 45.0 °C with 100 % (actually 86 %) RH, and measured tympanic temperature, mean skin temperature, heart rate (HR), and cheek moisture content, as well as ratings of thermal and sweating sensation tympanic temperatures at RT 45 °C were significantly higher at 86 % RH than those at 61 % RH; however, those at RT 45 °C with 61 % RH were higher than those with 86 % RH during recovery. There were no significant differences at RT 41.5 °C between with 81 % RH and with 96 % RH. Mean skin temperature was the highest at RT 45 °C 86 % RH case, followed by at RT 41.5 °C 96 % RH, RT 45 °C 61 % RH, RT 41.5 °C 81 % RH, and finally at RT 38 °C 91 % RH. HR change showed the same order as for mean skin temperature. A significant difference in cheek moisture content was observed between RT 41.5 °C with 81 % RH and RT 45 °C with 86 % RH 10 min after the micro mist bathing. There were no significant differences between ratings of thermal sensation at RT 41.5 °C with 81 % RH and at RT 45 °C with 61 % RH and RT 45 °C with 61 % RH and RT 45 °C with 86 % RH. Between RT 45 °C with 86 % RH and RT 41.5 °C with 81 % RH, there was a tendency for interaction (0.05 < p < 0.1). Other cases showed significant higher ratings of thermal sensation at higher room temperature or higher relative humidity. The ratings of sweating sensation 10 min after the mist sauna bathing were significantly higher at higher RT and RH except between RT 41.5 °C 96 % RH and RT 45 °C 86 % RH which exhibited no significant difference. We concluded that the micro mist sauna produced by water crushing method induced more moderate and effective thermal effect during micro mist sauna bathing than the conventional mist sauna bathing. In addition, micro mist sauna is as effective for heating the human subjects as bathtub bathing as well as more moderate thermal and sweating sensations.

  12. Nitric oxide synthase and cyclooxygenase modulate β-adrenergic cutaneous vasodilatation and sweating in young men.

    PubMed

    Fujii, Naoto; McNeely, Brendan D; Kenny, Glen P

    2017-02-15

    β-Adrenergic receptor agonists such as isoproterenol induce cutaneous vasodilatation and sweating in humans, but the mechanisms underpinning this response remain unresolved. Using intradermal microdialysis, we evaluated the roles of nitric oxide synthase (NOS) and cyclooxygenase (COX) in β-adrenergic cutaneous vasodilatation and sweating elicited by administration of isoproterenol. We show that while NOS contributes to β-adrenergic cutaneous vasodilatation, COX restricts cutaneous vasodilatation. We also show that combined inhibition of NOS and COX augments β-adrenergic sweating These new findings advance our basic knowledge regarding the physiological control of cutaneous blood flow and sweating, and provide important and new information to better understand the physiological significance of β-adrenergic receptors in the skin. β-Adrenergic receptor agonists such as isoproterenol can induce cutaneous vasodilatation and sweating in humans, but the mechanisms underpinning this response remain unresolved. We evaluated the hypotheses that (1) nitric oxide synthase (NOS) contributes to β-adrenergic cutaneous vasodilatation, whereas cyclooxygenase (COX) limits the vasodilatation, and (2) COX contributes to β-adrenergic sweating. In 10 young males (25 ± 5 years), cutaneous vascular conductance (CVC) and sweat rate were evaluated at four intradermal forearm skin sites infused with (1) lactated Ringer solution (control), (2) 10 mm N ω -nitro-l-arginine (l-NNA), a non-specific NOS inhibitor, (3) 10 mm ketorolac, a non-specific COX inhibitor, or (4) a combination of l-NNA and ketorolac. All sites were co-administered with a high dose of isoproterenol (100 μm) for 3 min to maximally induce β-adrenergic sweating (β-adrenergic sweating is significantly blunted by subsequent activations). Approximately 60 min after the washout period, three incremental doses of isoproterenol were co-administered (1, 10 and 100 μm each for 25 min). Increases in CVC induced by the first and second 100 μm isoproterenol were attenuated by l-NNA alone, and those in response to all doses of isoproterenol were reduced by l-NNA with co-infusion of ketorolac (all P ≤ 0.05). Ketorolac alone augmented increases in CVC induced by 10 μm and by the second 100 μm isoproterenol (both P ≤ 0.05). While isoproterenol-induced sweating was not affected by the separate administration of l-NNA or ketorolac (all P > 0.05), their combined administration augmented sweating elicited by the first 3 min of 100 μm isoproterenol (P = 0.05). We show that while NOS contributes to β-adrenergic cutaneous vasodilatation, COX restrains the vasodilatation. Finally, combined inhibition of NOS and COX augments β-adrenergic sweating. © 2016 The Authors. The Journal of Physiology © 2016 The Physiological Society.

  13. Pre-Exercise Ingestion of Pickle Juice, Hypertonic Saline, or Water and Aerobic Performance and Thermoregulation

    PubMed Central

    Peikert, Jarett; Miller, Kevin C.; Albrecht, Jay; Tucker, Jared; Deal, James

    2014-01-01

    Context: Ingesting high-sodium drinks pre-exercise can improve thermoregulation and performance. Athletic trainers (19%) give athletes pickle juice (PJ) prophylactically for cramping. No data exist on whether this practice affects aerobic performance or thermoregulation. Objective: To determine if drinking 2 mL/kg body mass of PJ, hypertonic saline, or deionized water (DIW) pre-exercise affects aerobic performance or thermoregulation. Design: Crossover study. Setting: Controlled laboratory study. Patients or Other Participants: Nine euhydrated men (age = 22 ± 3 years, height = 184.0 ± 8.2 cm, mass = 82.6 ± 16.0 kg) completed testing. Intervention(s): Participants rested for 65 minutes. During this period, they ingested 2 mL/kg of PJ, hypertonic saline, or DIW. Next, they drank 5 mL/kg of DIW. Blood was collected before and after ingestion of all fluids. Participants were weighed and ran in the heat (temperature = 38.3°C ± 1°C, relative humidity = 21.1% ± 4.7%) at increasing increments of maximal heart rate (50%, 60%, 70%, 80%, 90%, 95%) until exhaustion or until rectal temperature exceeded 39.5°C. Participants were weighed postexercise so we could calculate sweat volume. Main Outcome Measure(s): Time to exhaustion, rectal temperature, changes in plasma volume, and sweat volume. Results: Time to exhaustion did not differ among drinks (PJ = 77.4 ± 5.9 minutes, hypertonic saline = 77.4 ± 4.0 minutes, DIW = 75.7 ± 3.2 minutes; F2,16 = 1.1, P = .40). Core temperature of participants was similar among drinks (PJ = 38.7°C ± 0.3°C, hypertonic saline = 38.7°C ± 0.4°C, DIW = 38.8°C ± 0.4°C; P = .74) but increased from pre-exercise (36.7°C ± 0.2°C) to postexercise (38.7°C ± 0.4°C) (P < .05). No differences were observed for changes in plasma volume or sweat volume among drinks (P > .05). Conclusions: Ingesting small amounts of PJ or hypertonic saline with water did not affect performance or select thermoregulatory measures. Drinking larger volumes of PJ and water may be more effective at expanding the extracellular space. PMID:24568225

  14. Role of CFTR mutation analysis in the diagnostic algorithm for cystic fibrosis.

    PubMed

    Ratkiewicz, Michelle; Pastore, Matthew; McCoy, Karen Sharrock; Thompson, Rohan; Hayes, Don; Sheikh, Shahid Ijaz

    2017-04-01

    The cystic fibrosis transmembrane conductance regulator (CFTR) gene mutation identification is being used with increased frequency to aid in the diagnosis of cystic fibrosis (CF) in those suspected with CF. Aim of this study was to identify diagnostic outcomes when CFTR mutational analysis was used in CF diagnosis. CFTR mutational analysis results were also compared with sweat chloride results. This study was done on all patients at our institution who had CFTR mutation analysis over a sevenyear period since August 2006. A total of 315 patients underwent CFTR mutational analysis. Fifty-one (16.2%) patients had two mutations identified. Among them 32 had positive sweat chloride levels (≥60 mmol/L), while seven had borderline sweat chloride levels (40-59 mmol/L). An additional 70 patients (22.3%) had only one mutation identified. Among them eight had positive sweat chloride levels, and 17 had borderline sweat chloride levels. Fifty-five patients (17.5%) without CFTR mutations had either borderline (n=45) or positive (n=10) sweat chloride results. Three patients with a CF phenotype had negative CFTR analysis but elevated sweat chloride levels. In eighty-three patients (26.4%) CFTR mutational analysis was done without corresponding sweat chloride testing. Although CFTR mutation analysis has improved the diagnostic capability for CF, its use either as the first step or the only test to diagnose CFTR dysfunction should be discouraged and CF diagnostic guidelines need to be followed.

  15. Novel methods of imaging and analysis for the thermoregulatory sweat test.

    PubMed

    Carroll, Michael Sean; Reed, David W; Kuntz, Nancy L; Weese-Mayer, Debra Ellyn

    2018-06-07

    The thermoregulatory sweat test (TST) can be central to the identification and management of disorders affecting sudomotor function and small sensory and autonomic nerve fibers, but the cumbersome nature of the standard testing protocol has prevented its widespread adoption. A high resolution, quantitative, clean and simple assay of sweating could significantly improve identification and management of these disorders. Images from 89 clinical TSTs were analyzed retrospectively using two novel techniques. First, using the standard indicator powder, skin surface sweat distributions were determined algorithmically for each patient. Second, a fundamentally novel method using thermal imaging of forced evaporative cooling was evaluated through comparison with the standard technique. Correlation and receiver operating characteristic analyses were used to determine the degree of match between these methods, and the potential limits of thermal imaging were examined through cumulative analysis of all studied patients. Algorithmic encoding of sweating and non-sweating regions produces a more objective analysis for clinical decision making. Additionally, results from the forced cooling method correspond well with those from indicator powder imaging, with a correlation across spatial regions of -0.78 (CI: -0.84 to -0.71). The method works similarly across body regions, and frame-by-frame analysis suggests the ability to identify sweating regions within about 1 second of imaging. While algorithmic encoding can enhance the standard sweat testing protocol, thermal imaging with forced evaporative cooling can dramatically improve the TST by making it less time-consuming and more patient-friendly than the current approach.

  16. Regional differences in sweat rate response of steers to short-term heat stress

    USDA-ARS?s Scientific Manuscript database

    Six Angus steers (319±8.5 kg) were assigned to one of two groups (hot or cold exposure) of three steers each, and placed into two environmental chambers initially maintained at 16.5–18.8°C air temperature (Ta). cold chamber Ta was lowered to 8.4°C, while Ta within the hot chamber was increased to 32...

  17. Modelling of Heat and Moisture Loss Through NBC Ensembles

    DTIC Science & Technology

    1991-11-01

    the heat and moisture transport through various NBC clothing ensembles. The analysis involves simplifying the three dimensional physical problem of... clothing on a person to that of a one dimensional problem of flow through parallel layers of clothing and air. Body temperatures are calculated based on...prescribed work rates, ambient conditions and clothing properties. Sweat response and respiration rates are estimated based on empirical data to

  18. Physiological Responses to Acute Exercise-Heat Stress

    DTIC Science & Technology

    1988-01-01

    muscle contraction and to dissipate the associated heat release. In hot environments, the core to skin temperature gradient is reduced to skin blood flow needs to be relatively high (compared to cooler environments) to achieve heat transfer sufficient for thermal balance. In addition, sweat secretion can result in a reduced plasma (by dehydration) and thus blood volume. Both high skin blood flow and reduced plasma volume can reduce

  19. Exercise Thermoregulation After 6 hours of Chair Rest, 6 deg Head-Down Bed-Rest, and Water Immersion Deconditioning in Men

    NASA Technical Reports Server (NTRS)

    Greenleaf, J. E.; Hutchinson, T.; Shaffer-Bailey, M.; Looft-Wilson, R.

    1996-01-01

    The purpose was to investigate the mechanism for the excessive exercise hyperthermia following deconditioning (reduction of physical fitness). Rectal (T(sub re)) and mean skin (T(bar)(sub sk)) temperatures and thermoregulatory responses were measured in six men [mean (SD) age, 32 (6) years; mass, 78.26 (5.80) kg; surface area, 1.95 (0.11) sq m; maximum oxygen uptake (VO2max), 48 (6) ml/min/kg; whilst supine in air at dry bulb temperature 23.2 (0.6)C, relative humidity 31.1 (11.1)% and air speed 5.6 (0.1) m/min] during 70 min of leg cycle exercise [51 (4)% VO2max] in ambulatory control (AC), or following 6 h of chair rest (CR), 6deg head-down bed rest (BR), and 20deg (W120) and 80deg (W180) foot-down water immersion [water temperature, 35.0 (0.1) C]. Compared with the AC exercise (Delta)T(sub re) [mean (SD) 0.77 (0.13)C], (Delta)T(sub re), after CR was 0.83 (0.08)C (NS), after BR 0.92 (0.13)C (*P <0.05), after W180 0.96 (0.13)C*, and after W120 1.03 (0.09)C*. All T(sub sk) responded similarly to exercise: they decreased (NS) by 0.5-0.7 C in minutes 4-8 and equilibrated at +0.1 to +0.5 C at 60-70. Skin heat conductance was not different among the five conditions (range = 147-159 kJ/sq/C. Results from an intercorrelation matrix suggested that total body sweat rate was more closely related to T(sub re) at 70 min (T(sub re70)) than limb sweat rate or blood flow. Only 36% of the variability in T(sub re70) could be accounted for by total sweating, and less than 10% from total body dehydration. It would appear that multiple factors are involved which may include change in sensitivity of thermo- and osmoreceptors.

  20. 7 CFR 29.2559 - Sweating.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 2 2012-01-01 2012-01-01 false Sweating. 29.2559 Section 29.2559 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing...-Cured Tobacco (u.s. Types 22, 23, and Foreign Type 96) § 29.2559 Sweating. The condition of tobacco in...

  1. 7 CFR 29.2559 - Sweating.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Sweating. 29.2559 Section 29.2559 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing...-Cured Tobacco (u.s. Types 22, 23, and Foreign Type 96) § 29.2559 Sweating. The condition of tobacco in...

  2. 7 CFR 29.2559 - Sweating.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 2 2013-01-01 2013-01-01 false Sweating. 29.2559 Section 29.2559 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing...-Cured Tobacco (u.s. Types 22, 23, and Foreign Type 96) § 29.2559 Sweating. The condition of tobacco in...

  3. 7 CFR 29.2559 - Sweating.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 2 2011-01-01 2011-01-01 false Sweating. 29.2559 Section 29.2559 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing...-Cured Tobacco (u.s. Types 22, 23, and Foreign Type 96) § 29.2559 Sweating. The condition of tobacco in...

  4. 7 CFR 29.2559 - Sweating.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 2 2014-01-01 2014-01-01 false Sweating. 29.2559 Section 29.2559 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing...-Cured Tobacco (u.s. Types 22, 23, and Foreign Type 96) § 29.2559 Sweating. The condition of tobacco in...

  5. Field Testing and Modeling of Supermarket Refrigeration Systems as a Demand Response Resource

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Deru, Michael; Hirsch, Adam; Clark, Jordan

    Supermarkets offer a substantial demand response (DR) resource because of their high energy intensity and use patterns; however, refrigeration as the largest load has been challenging to access. Previous work has analyzed supermarket DR using heating, ventilating, and air conditioning; lighting; and anti-sweat heaters. This project evaluated and quantified the DR potential inherent in supermarket refrigeration systems in the Bonneville Power Administration service territory. DR events were carried out and results measured in an operational 45,590-ft2 supermarket located in Hillsboro, Oregon. Key results from the project include the rate of temperature increase in freezer reach-in cases and walk-ins when refrigerationmore » is suspended, the load shed amount for DR tests, and the development of calibrated models to quantify available DR resources. Simulations showed that demand savings of 15 to 20 kilowatts (kW) are available for 1.5 hours for a typical store without precooling and for about 2.5 hours with precooling using only the low-temperature, non-ice cream cases. This represents an aggregated potential of 20 megawatts within BPA's service territory. Inability to shed loads for medium-temperature (MT) products because of the tighter temperature requirements is a significant barrier to realizing larger DR for supermarkets. Store owners are reluctant to allow MT case set point changes, and laboratory tests of MT case DR strategies are needed so that owners become comfortable testing, and implementing, MT case DR. The next-largest barrier is the lack of proper controls in most supermarket displays over ancillary equipment, such as anti-sweat heaters, lights, and fans.« less

  6. 12 CFR 1291.5 - Competitive application program.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... (excluding the value of sweat equity), provided that the project's uses of funds also include or exclude... project. Cash costs do not include in-kind donations, voluntary professional labor or services, or sweat... services (excluding the value of sweat equity) committed to the project as part of the total development...

  7. 12 CFR 1291.5 - Competitive application program.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... (excluding the value of sweat equity), provided that the project's uses of funds also include or exclude... project. Cash costs do not include in-kind donations, voluntary professional labor or services, or sweat... services (excluding the value of sweat equity) committed to the project as part of the total development...

  8. 12 CFR 1291.5 - Competitive application program.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... (excluding the value of sweat equity), provided that the project's uses of funds also include or exclude... project. Cash costs do not include in-kind donations, voluntary professional labor or services, or sweat... services (excluding the value of sweat equity) committed to the project as part of the total development...

  9. 12 CFR 1291.5 - Competitive application program.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... (excluding the value of sweat equity), provided that the project's uses of funds also include or exclude... project. Cash costs do not include in-kind donations, voluntary professional labor or services, or sweat... services (excluding the value of sweat equity) committed to the project as part of the total development...

  10. Efficacy response in CF patients treated with ivacaftor: post-hoc analysis.

    PubMed

    Konstan, Michael W; Plant, Barry J; Elborn, J Stuart; Rodriguez, Sally; Munck, Anne; Ahrens, Richard; Johnson, Charles

    2015-05-01

    Clinical studies in patients with cystic fibrosis and G551D-CFTR showed that the group treated with ivacaftor had improved clinical outcomes. To better understand the effect of ivacaftor therapy across the distribution of individual FEV(1) responses, data from Phase 3 studies (STRIVE/ENVISION) were re-examined. In this post-hoc analysis of patients (n = 209) who received 48 weeks of ivacaftor or placebo, patients were assigned to tertiles according to FEV(1) response. These groups were then used to evaluate response (FEV(1), sweat chloride, weight, CFQ-R, and pulmonary exacerbation). The number needed to treat (NNT) was calculated for specific thresholds for each outcome. Across all tertiles, numerical improvements in FEV(1), sweat chloride, CFQ-R and the frequency of pulmonary exacerbations were observed in ivacaftor-treated patients: the treatment difference versus placebo was statistically significant for all outcomes in the upper tertile and for some outcomes in the lower and middle tertiles. The NNT for a ≥ 5% improvement in %predicted FEV(1) was 1.90, for a ≥ 5% body weight increase was 5.74, and to prevent a pulmonary exacerbation was 3.85. This analysis suggests that the majority of patients with clinical characteristics similar to STRIVE/ENVISION patients have the potential to benefit from ivacaftor therapy. © 2015 Wiley Periodicals, Inc.

  11. Skin-interfaced systems for sweat collection and analytics

    PubMed Central

    Choi, Jungil; Ghaffari, Roozbeh; Baker, Lindsay B.; Rogers, John A.

    2018-01-01

    Recent interdisciplinary advances in materials, mechanics, and microsystem designs for biocompatible electronics, soft microfluidics, and electrochemical biosensors establish the foundations for emerging classes of thin, skin-interfaced platforms capable of capturing, storing, and performing quantitative, spatiotemporal measurements of sweat chemistry, instantaneous local sweat rate, and total sweat loss. This review summarizes scientific and technical progress in this area and highlights the implications in real time and ambulatory modes of deployment during physical activities across a broad range of contexts in clinical health, physiology research, fitness/wellness, and athletic performance. PMID:29487915

  12. Effect of two sweating simulation methods on clothing evaporative resistance in a so-called isothermal condition.

    PubMed

    Lu, Yehu; Wang, Faming; Peng, Hui

    2016-07-01

    The effect of sweating simulation methods on clothing evaporative resistance was investigated in a so-called isothermal condition (T manikin  = T a  = T r ). Two sweating simulation methods, namely, the pre-wetted fabric "skin" (PW) and the water supplied sweating (WS), were applied to determine clothing evaporative resistance on a "Newton" thermal manikin. Results indicated that the clothing evaporative resistance determined by the WS method was significantly lower than that measured by the PW method. In addition, the evaporative resistances measured by the two methods were correlated and exhibited a linear relationship. Validation experiments demonstrated that the empirical regression equation showed highly acceptable estimations. The study contributes to improving the accuracy of measurements of clothing evaporative resistance by means of a sweating manikin.

  13. Stretchable, wireless sensors and functional substrates for epidermal characterization of sweat.

    PubMed

    Huang, Xian; Liu, Yuhao; Chen, Kaile; Shin, Woo-Jung; Lu, Ching-Jui; Kong, Gil-Woo; Patnaik, Dwipayan; Lee, Sang-Heon; Cortes, Jonathan Fajardo; Rogers, John A

    2014-08-13

    This paper introduces materials and architectures for ultrathin, stretchable wireless sensors that mount on functional elastomeric substrates for epidermal analysis of biofluids. Measurement of the volume and chemical properties of sweat via dielectric detection and colorimetry demonstrates some capabilities. Here, inductively coupled sensors consisting of LC resonators with capacitive electrodes show systematic responses to sweat collected in microporous substrates. Interrogation occurs through external coils placed in physical proximity to the devices. The substrates allow spontaneous sweat collection through capillary forces, without the need for complex microfluidic handling systems. Furthermore, colorimetric measurement modes are possible in the same system by introducing indicator compounds into the depths of the substrates, for sensing specific components (OH(-) , H(+) , Cu(+) , and Fe(2+) ) in the sweat. The complete devices offer Young's moduli that are similar to skin, thus allowing highly effective and reliable skin integration without external fixtures. Experimental results demonstrate volumetric measurement of sweat with an accuracy of 0.06 μL/mm(2) with good stability and low drift. Colorimetric responses to pH and concentrations of various ions provide capabilities relevant to analysis of sweat. Similar materials and device designs can be used in monitoring other body fluids. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Human Elimination of Phthalate Compounds: Blood, Urine, and Sweat (BUS) Study

    PubMed Central

    Genuis, Stephen J.; Beesoon, Sanjay; Lobo, Rebecca A.; Birkholz, Detlef

    2012-01-01

    Background. Individual members of the phthalate family of chemical compounds are components of innumerable everyday consumer products, resulting in a high exposure scenario for some individuals and population groups. Multiple epidemiological studies have demonstrated statistically significant exposure-disease relationships involving phthalates and toxicological studies have shown estrogenic effects in vitro. Data is lacking in the medical literature, however, on effective means to facilitate phthalate excretion. Methods. Blood, urine, and sweat were collected from 20 individuals (10 healthy participants and 10 participants with assorted health problems) and analyzed for parent phthalate compounds as well as phthalate metabolites using high performance liquid chromatography-tandem mass spectrometry. Results. Some parent phthalates as well as their metabolites were excreted into sweat. All patients had MEHP (mono(2-ethylhexyl) phthalate) in their blood, sweat, and urine samples, suggesting widespread phthalate exposure. In several individuals, DEHP (di (2-ethylhexl) phthalate) was found in sweat but not in serum, suggesting the possibility of phthalate retention and bioaccumulation. On average, MEHP concentration in sweat was more than twice as high as urine levels. Conclusions. Induced perspiration may be useful to facilitate elimination of some potentially toxic phthalate compounds including DEHP and MEHP. Sweat analysis may be helpful in establishing the existence of accrued DEHP in the human body. PMID:23213291

  15. A soft, wearable microfluidic device for the capture, storage, and colorimetric sensing of sweat.

    PubMed

    Koh, Ahyeon; Kang, Daeshik; Xue, Yeguang; Lee, Seungmin; Pielak, Rafal M; Kim, Jeonghyun; Hwang, Taehwan; Min, Seunghwan; Banks, Anthony; Bastien, Philippe; Manco, Megan C; Wang, Liang; Ammann, Kaitlyn R; Jang, Kyung-In; Won, Phillip; Han, Seungyong; Ghaffari, Roozbeh; Paik, Ungyu; Slepian, Marvin J; Balooch, Guive; Huang, Yonggang; Rogers, John A

    2016-11-23

    Capabilities in health monitoring enabled by capture and quantitative chemical analysis of sweat could complement, or potentially obviate the need for, approaches based on sporadic assessment of blood samples. Established sweat monitoring technologies use simple fabric swatches and are limited to basic analysis in controlled laboratory or hospital settings. We present a collection of materials and device designs for soft, flexible, and stretchable microfluidic systems, including embodiments that integrate wireless communication electronics, which can intimately and robustly bond to the surface of the skin without chemical and mechanical irritation. This integration defines access points for a small set of sweat glands such that perspiration spontaneously initiates routing of sweat through a microfluidic network and set of reservoirs. Embedded chemical analyses respond in colorimetric fashion to markers such as chloride and hydronium ions, glucose, and lactate. Wireless interfaces to digital image capture hardware serve as a means for quantitation. Human studies demonstrated the functionality of this microfluidic device during fitness cycling in a controlled environment and during long-distance bicycle racing in arid, outdoor conditions. The results include quantitative values for sweat rate, total sweat loss, pH, and concentration of chloride and lactate. Copyright © 2016, American Association for the Advancement of Science.

  16. Revisiting sweat chloride test results based on recent guidelines for diagnosis of cystic fibrosis.

    PubMed

    Pagaduan, Jayson V; Ali, Mahesheema; Dowlin, Michael; Suo, Liye; Ward, Tabitha; Ruiz, Fadel; Devaraj, Sridevi

    2018-03-01

    Recent sweat chloride guidelines published by the Cystic Fibrosis Foundation changed the intermediate sweat chloride concentration range from 40-59 mmol/L to 30-59 mmol/L for age > 6 months. We wanted to know how this new guideline would impact detection of cystic fibrosis among patients who previously had sweat tests done at Texas Children's Hospital. We revisited sweat chloride test results (n = 3012) in the last 5 years at Texas Children's Hospital based on the new guidelines on diagnosis of cystic fibrosis from the Cystic Fibrosis Foundation. We identified 125 patients that would be reclassified in the intermediate sweat chloride value with the new guidelines that were classified as "unlikely to have CF" in the previous guidelines. 8 (32%) patients with CFTR gene testing were positive for CFTR gene mutation(s). 4 (50%) of these patients were identified to have 2 CFTR mutations. One had variant combination that was reported to cause CF but all were diagnosed with CFTR-related metabolic syndrome. Our findings concur with the new CF diagnosis guidelines that changing the intermediate cut-off to 30-59 mmol/L sweat chloride concentration in combination with CFTR genetic analysis enhances the probability of identifying individuals that have risk of developing CF or have CF and enables for earlier therapeutic intervention.

  17. Assessment of physical demands and fluid balance in elite female handball players during a 6-day competitive tournament.

    PubMed

    Cunniffe, Brian; Fallan, Carissa; Yau, Adora; Evans, Gethin H; Cardinale, Marco

    2015-02-01

    Little data exists on drinking behavior, sweat loss, and exercise intensity across a competitive handball tournament in elite female athletes. Heart rate (HR), fluid balance and sweat electrolyte content were assessed on 17 international players across a 6-day tournament involving 5 games and 2 training sessions played indoors (23 ± 2 °C, 30 ± 2% relative humidity). Active play (effective) mean HR was 155 ± 14 bpm (80 ± 7.5% HRmax) with the majority of time (64%) spent exercising at intensities >80% HRmax. Mean (SD) sweat rates during games were 1.02 ± 0.07 L · h⁻¹ and on 56% of occasions fluid intake matched or exceeded sweat loss. A significant relationship was observed between estimated sweat loss and fluid intake during exercise (r² = .121, p = .001). Mean sweat sodium concentration was 38 ± 10 mmol · L⁻¹, with significant associations observed between player sweat rates and time spent exercising at intensities >90% HRmax (r² = .181, p = .001). Fluid and electrolyte loss appear to be work rate dependent in elite female handball players, whom appear well capable of replacing fluids lost within a tournament environment. Due to large between-athlete variations, a targeted approach may be warranted for certain players only.

  18. Effects of Temperature on the Histotripsy Intrinsic Threshold for Cavitation.

    PubMed

    Vlaisavljevich, Eli; Xu, Zhen; Maxwell, Adam; Mancia, Lauren; Zhang, Xi; Lin, Kuang-Wei; Duryea, Alexander; Sukovich, Jonathan; Hall, Tim; Johnsen, Eric; Cain, Charles

    2016-05-10

    Histotripsy is an ultrasound ablation method that depends on the initiation of a dense cavitation bubble cloud to fractionate soft tissue. Previous work has demonstrated that a cavitation cloud can be formed by a single acoustic pulse with one high amplitude negative cycle, when the negative pressure amplitude exceeds a threshold intrinsic to the medium. The intrinsic thresholds in soft tissues and tissue phantoms that are water-based are similar to the intrinsic threshold of water over an experimentally verified frequency range of 0.3-3 MHz. Previous work studying the histotripsy intrinsic threshold has been limited to experiments performed at room temperature (~20°C). In this study, we investigate the effects of temperature on the histotripsy intrinsic threshold in water, which is essential to accurately predict the intrinsic thresholds expected over the full range of in vivo therapeutic temperatures. Based on previous work studying the histotripsy intrinsic threshold and classical nucleation theory, we hypothesize that the intrinsic threshold will decrease with increasing temperature. To test this hypothesis, the intrinsic threshold in water was investigated both experimentally and theoretically. The probability of generating cavitation bubbles was measured by applying a single pulse with one high amplitude negative cycle at 1 MHz to distilled, degassed water at temperatures ranging from 10°C-90°C. Cavitation was detected and characterized by passive cavitation detection and high-speed photography, from which the probability of cavitation was measured vs. pressure amplitude. The results indicate that the intrinsic threshold (the negative pressure at which the cavitation probability=0.5) significantly decreases with increasing temperature, showing a nearly linear decreasing trend from 29.8±0.4 MPa at 10˚C to 14.9±1.4 MPa at 90˚C. Overall, the results of this study support our hypothesis that the intrinsic threshold is highly dependent upon the temperature of the medium, which may allow for better predictions of cavitation generation at body temperature in vivo and at the elevated temperatures commonly seen in high intensity focused ultrasound (HIFU) regimes.

  19. Effects of Temperature on the Histotripsy Intrinsic Threshold for Cavitation

    PubMed Central

    Vlaisavljevich, Eli; Xu, Zhen; Maxwell, Adam; Mancia, Lauren; Zhang, Xi; Lin, Kuang-Wei; Duryea, Alexander; Sukovich, Jonathan; Hall, Tim; Johnsen, Eric; Cain, Charles

    2018-01-01

    Histotripsy is an ultrasound ablation method that depends on the initiation of a dense cavitation bubble cloud to fractionate soft tissue. Previous work has demonstrated that a cavitation cloud can be formed by a single acoustic pulse with one high amplitude negative cycle, when the negative pressure amplitude exceeds a threshold intrinsic to the medium. The intrinsic thresholds in soft tissues and tissue phantoms that are water-based are similar to the intrinsic threshold of water over an experimentally verified frequency range of 0.3–3 MHz. Previous work studying the histotripsy intrinsic threshold has been limited to experiments performed at room temperature (~ 20°C). In this study, we investigate the effects of temperature on the histotripsy intrinsic threshold in water, which is essential to accurately predict the intrinsic thresholds expected over the full range of in vivo therapeutic temperatures. Based on previous work studying the histotripsy intrinsic threshold and classical nucleation theory, we hypothesize that the intrinsic threshold will decrease with increasing temperature. To test this hypothesis, the intrinsic threshold in water was investigated both experimentally and theoretically. The probability of generating cavitation bubbles was measured by applying a single pulse with one high amplitude negative cycle at 1 MHz to distilled, degassed water at temperatures ranging from 10°C–90°C. Cavitation was detected and characterized by passive cavitation detection and high-speed photography, from which the probability of cavitation was measured vs. pressure amplitude. The results indicate that the intrinsic threshold (the negative pressure at which the cavitation probability = 0.5) significantly decreases with increasing temperature, showing a nearly linear decreasing trend from 29.8±0.4 MPa at 10°C to 14.9±1.4 MPa at 90°C. Overall, the results of this study support our hypothesis that the intrinsic threshold is highly dependent upon the temperature of the medium, which may allow for better predictions of cavitation generation at body temperature in vivo and at the elevated temperatures commonly seen in high intensity focused ultrasound (HIFU) regimes. PMID:28113706

  20. Heat regulation: homeostasis of central temperature in man.

    PubMed

    Benzinger, T H

    1969-10-01

    Focus is on the concept of the quantitative thermostat or setpoint as it evolved experimentally, not theoretically, from measurements of central temperature at the tympanic membrane and from measurements of physiological responses by human gradient layer calorimetry and continuous analysis of oxygen consumption. Heat-flow responses as they relate to stimuli by which they are evoked -- peripheral or central temperatures at thermoreceptive sites -- and discussed, and individual systems of reflex action are described. These systems are then correlated with what is known of their tangible components -- sensory receptors, effector organs, nervous centers, and afferent or efferent nervous pathways -- classically derived from anatomical studies, lesion experiments, recording of action currents, or electrical or thermal stimulation of pertinent structures. Such as correlation is a crucial test, and when the results are consistent, they provide independent, mutual confirmation via the 2 approaches. Doubts are then removed that lesions or interferences, which are unavoidable with most neurophysiological methods, may have produced artifacts. Conversely, calorimetry allows one to observe and analyze thermoregulation in process in a human subject without disturbing normal structures or functions other than by the stresses to which the body is made to respond. Prior to a description of experimental findings, the essential methods are reviewed. With the methods of gradient layer calorimetry, tympanic (eardrum) thermonetry, and indirect calorimetry, thermoregulatory responses -- by chemical overproduction of metabolic heat -- were observed in transient states as a result of a stimulus of cold impinging on peripheral neurons or warm-inhibition removed from central structures. With tympanic thermometry permitting for the 1st time om humans the continuous recording of central thermal stimulation, and with gradient calorimetry permitting the continuous recording (with insignificant inertial distortion) of the sweating responses in precisely controlled environments of a large variety and under conditions where complete evaporation of sweat is ensured by strong but smooth air convection, a new study of physical thermoregulation was initiated in 1958. The experimental results did not support the expection that sweating would follow the average temperature of the skin in the classical tradition, with skin warm-receptors as the hypothetical origin of exciting warm-impulses and cenral temperature as a participant prescribing the action of the "thermoregulator" in some as yet undetermined, additive, manner. Vasomotor mechanisms to human thermoregulation can be assessed in quantitative manner only by whole-body calorimetry. Mechanisms of thermal homeostasis also considered include hormonal regulation, transmitter substances, conscious sensation of warmth and coordinations of behavioral and autonomic mechanisms, setpoint and its variations, and fever.

  1. Automatic dew-point temperature sensor.

    PubMed

    Graichen, H; Rascati, R; Gonzalez, R R

    1982-06-01

    A device is described for measuring dew-point temperature and water vapor pressure in small confined areas. The method is based on the deposition of water on a cooled surface when at dew-point temperature. A small Peltier module lowers the temperature of two electrically conductive plates. At dew point the insulating gap separating the plates becomes conductive as water vapor condenses. Sensors based on this principle can be made small and rugged and can be used for measuring directly the local water vapor pressure. They may be installed within a conventional ventilated sweat capsule used for measuring water vapor loss from the skin surface. A novel application is the measurement of the water vapor pressure gradients across layers of clothing worn by an exercising subject.

  2. Qualification of a precise and easy-to-handle sweat casting imprint method for the prediction and quantification of anti-perspirant efficacy.

    PubMed

    Keyhani, R; Scheede, S; Thielecke, I; Wenck, H; Schmucker, R; Schreiner, V; Ennen, J; Herpens, A

    2009-06-01

    A time- and cost-effective sweat casting method using the forearm as test site to assess the efficacy of several anti-perspirant formulations with a low number of test subjects has been evaluated and qualified. The imprint sweat casting method is based on a 2-component silcone-imprint technique to measure the efficacy of more than eight products in parallel with the same test subject. In studies using aluminum chlorohydrate (ACH) formulations as test anti-perspirants, a clear-cut correlation could be demonstrated between sweat gland activities measured by the imprint method and gravimetric measurement of sweat gland activities. Concentration-dependent inhibition of sweat gland activity could be observed with the imprint technique up to an ACH concentration of 15%, and all formulations containing 2% ACH or above resulted in statistically significant reduction of sweat gland activity (P < 0.001) when compared with untreated control areas. Furthermore, the SDs of individual studies using the imprint technique were in a range of +/-20% of sweat gland activity, which can be regarded rather low for in vivo measurements of a complex process like sweat secretion. A group-wise comparison between the measurements of anti-perspirant activity as determined by the imprint protocol and the Food and Drug Administration (FDA) Guideline compliant gravimetric hot-room protocol revealed that the test results for anti-perspirant activity obtained with the imprint protocol are similar to those obtained with the hot-room protocol. Moreover, the data generated with the imprint protocol have a high predictive value for the outcome of a later guideline-compliant hot-room test. As the imprint casting method tends to be a little more sensitive for formulations with low anti-perspirant activity, and seems to be associated with less interassay variability than the standard gravimetric hot-room test, the imprint casting method may select products which later fail to pass the standard gravimetric hot-room test. Meanwhile the imprint sweat casting has proven to be a robust method useful to support efficacy-oriented product development. Therefore, in later stages of utilization it might even evolve into an efficient claim substantiation tool.

  3. Skin pretreatment with microneedles prior to pilocarpine iontophoresis increases sweat production.

    PubMed

    Wing, David; Prausnitz, Mark R; Buono, Michael J

    2013-11-01

    Collection of sweat via pilocarpine iontophoresis is commonly used to diagnose cystic fibrosis (CF), with thousands of tests performed each day. The main source of resistance to the passage of pilocarpine ions to the sweat glands is the electrical resistance of the stratum corneum. It was hypothesized that pretreating the skin with 0·5 mm-long microneedles would significantly decrease this resistance, thus increasing pilocarpine's permeation into the skin. Improved permeation should result in significantly reduced time to sweat initiation, time to collection of a clinically meaningful amount of sweat, and increased total amount of sweat produced in 15 min. Subjects (n = 12) had two 5 cm(2) areas on the forearm measured, marked and randomized to experimental (microneedles + iontophoresis) or control (iontophoresis alone). Microneedle pretreatment was conducted using a 35-needle microneedle stamp in a manner that 20 applications completely covered the 5 cm(2) treatment area. This was repeated five times for a total of 100 applications. Both experimental and control sites were placed under iontophoresis (1·5 mA) for 5 min. Microneedle pretreatment significantly decreased mean skin resistance (260 ± 27 kΩ versus 160 ± 19 kΩ, P = 0·006), while significantly increasing mean sweat rate (0·76 ± 0·35 versus 0·54 ± 0·19 μl cm(2) min(-1) , P = 0·007). No significant difference was found concerning pain (P = 0·059), number of active sweat glands (P = 0·627) or the osmolality of the collected sweat (P = 0·636). The results of this study suggest that microneedle pretreatment prior to pilocarpine iontophoresis significantly increases sweat production. Such results have the potential to improve the methodology currently used to diagnose cystic fibrosis and, more broadly, to administer drugs via the skin. © 2013 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.

  4. The significance of hypersensitivity to autologous sweat and serum in cholinergic urticaria: cholinergic urticaria may have different subtypes.

    PubMed

    Kim, Jung Eun; Jung, Kwan Ho; Cho, Hyun Hee; Kang, Hoon; Park, Young Min; Park, Hyun Jeong; Lee, Jun Young

    2015-07-01

    The pathogenesis of cholinergic urticaria (ChU) has been unclear except for the involvement of acetylcholine. Attempts to classify ChU according to etiology have rarely been performed. To evaluate the significance of responsiveness to autologous sweat and serum in ChU in relation to their clinical characteristics. This study involved 18 patients diagnosed with ChU between January 2010 and April 2011 in the Catholic Medical Center-St. Paul's Hospital. History taking included symptom duration, association with atopy, decreased sweat secretions, seasonal variation, and response to treatment. Intradermal autologous serum skin test (ASST) and autologous sweat skin test (ASwST) and basophil histamine release test with sweat were done. Sweat hypersensitivity was proven by a positive ASwST and basophil histamine release test in only 37.5% of patients with ChU, and in none of the healthy controls. The weal size of ASwST correlated with percentage basophil histamine release. A positive response to autologous serum was displayed by 38.9% of patients, whereas 10% of healthy controls showed a positive ASST response. Intriguingly, patients with a positive ASwST had a negative ASST, and vice versa. Despite this, there was no difference in the clinical characteristics between positive ASST and positive ASwST groups. The frequency of hypersensitivity to autologous sweat and serum was significantly higher in patients with ChU, compared with healthy controls. This suggests that autoimmunity to an unknown serum factor as well as sweat hypersensitivity may be involved in the pathogenesis of ChU. © 2014 The International Society of Dermatology.

  5. Nitric oxide synthase and cyclooxygenase modulate β‐adrenergic cutaneous vasodilatation and sweating in young men

    PubMed Central

    Fujii, Naoto; McNeely, Brendan D.

    2016-01-01

    Key points β‐Adrenergic receptor agonists such as isoproterenol induce cutaneous vasodilatation and sweating in humans, but the mechanisms underpinning this response remain unresolved.Using intradermal microdialysis, we evaluated the roles of nitric oxide synthase (NOS) and cyclooxygenase (COX) in β‐adrenergic cutaneous vasodilatation and sweating elicited by administration of isoproterenol.We show that while NOS contributes to β‐adrenergic cutaneous vasodilatation, COX restricts cutaneous vasodilatation.We also show that combined inhibition of NOS and COX augments β‐adrenergic sweatingThese new findings advance our basic knowledge regarding the physiological control of cutaneous blood flow and sweating, and provide important and new information to better understand the physiological significance of β‐adrenergic receptors in the skin. Abstract β‐Adrenergic receptor agonists such as isoproterenol can induce cutaneous vasodilatation and sweating in humans, but the mechanisms underpinning this response remain unresolved. We evaluated the hypotheses that (1) nitric oxide synthase (NOS) contributes to β‐adrenergic cutaneous vasodilatation, whereas cyclooxygenase (COX) limits the vasodilatation, and (2) COX contributes to β‐adrenergic sweating. In 10 young males (25 ± 5 years), cutaneous vascular conductance (CVC) and sweat rate were evaluated at four intradermal forearm skin sites infused with (1) lactated Ringer solution (control), (2) 10 mm N ω‐nitro‐l‐arginine (l‐NNA), a non‐specific NOS inhibitor, (3) 10 mm ketorolac, a non‐specific COX inhibitor, or (4) a combination of l‐NNA and ketorolac. All sites were co‐administered with a high dose of isoproterenol (100 μm) for 3 min to maximally induce β‐adrenergic sweating (β‐adrenergic sweating is significantly blunted by subsequent activations). Approximately 60 min after the washout period, three incremental doses of isoproterenol were co‐administered (1, 10 and 100 μm each for 25 min). Increases in CVC induced by the first and second 100 μm isoproterenol were attenuated by l‐NNA alone, and those in response to all doses of isoproterenol were reduced by l‐NNA with co‐infusion of ketorolac (all P ≤ 0.05). Ketorolac alone augmented increases in CVC induced by 10 μm and by the second 100 μm isoproterenol (both P ≤ 0.05). While isoproterenol‐induced sweating was not affected by the separate administration of l‐NNA or ketorolac (all P > 0.05), their combined administration augmented sweating elicited by the first 3 min of 100 μm isoproterenol (P = 0.05). We show that while NOS contributes to β‐adrenergic cutaneous vasodilatation, COX restrains the vasodilatation. Finally, combined inhibition of NOS and COX augments β‐adrenergic sweating. PMID:27779753

  6. 40 CFR 63.1506 - Operating requirements.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... equipment according to the requirements in this section. (2) The owner or operator of an existing sweat furnace that meets the specifications of § 63.1505(f)(1) must operate the sweat furnace and control.... (3) The owner or operator of a new sweat furnace that meets the specifications of § 63.1505(f)(1...

  7. 24 CFR 572.130 - Restrictions on resale by initial homeowners.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... equity paid by the family (such as any downpayment (in the form of cash or the value of sweat equity) and... family during the family's tenure as owner (including improvements made through sweat equity), as... amounts spent on the improvements, including the cost of material and labor (or the value of the sweat...

  8. 40 CFR 63.1506 - Operating requirements.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... equipment according to the requirements in this section. (2) The owner or operator of an existing sweat furnace that meets the specifications of § 63.1505(f)(1) must operate the sweat furnace and control.... (3) The owner or operator of a new sweat furnace that meets the specifications of § 63.1505(f)(1...

  9. 24 CFR 572.130 - Restrictions on resale by initial homeowners.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... equity paid by the family (such as any downpayment (in the form of cash or the value of sweat equity) and... family during the family's tenure as owner (including improvements made through sweat equity), as... amounts spent on the improvements, including the cost of material and labor (or the value of the sweat...

  10. 24 CFR 572.130 - Restrictions on resale by initial homeowners.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... equity paid by the family (such as any downpayment (in the form of cash or the value of sweat equity) and... family during the family's tenure as owner (including improvements made through sweat equity), as... amounts spent on the improvements, including the cost of material and labor (or the value of the sweat...

  11. 24 CFR 572.130 - Restrictions on resale by initial homeowners.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... equity paid by the family (such as any downpayment (in the form of cash or the value of sweat equity) and... family during the family's tenure as owner (including improvements made through sweat equity), as... amounts spent on the improvements, including the cost of material and labor (or the value of the sweat...

  12. 24 CFR 572.130 - Restrictions on resale by initial homeowners.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... equity paid by the family (such as any downpayment (in the form of cash or the value of sweat equity) and... family during the family's tenure as owner (including improvements made through sweat equity), as... amounts spent on the improvements, including the cost of material and labor (or the value of the sweat...

  13. PAR-2 receptor-induced effects on human eccrine sweat gland cells.

    PubMed

    L Bovell, Douglas; Kofler, Barbara; Lang, Roland

    2009-01-01

    Serine proteases can induce cell signaling by stimulating G-protein-coupled receptors, called proteinase-activated receptors (PAR's) on a variety of epithelial cells. While PAR-2, one such receptor, activates cell signaling in a secretory cell line derived from human sweat glands, there was no information on their presence and effects on intact sweat glands. PAR-2 presence and activation of eccrine sweat glands isolated from human skin samples was investigated using Western blot analysis, immunohistochemistry, electron microscopy (EM) and Ca(2+) imaging. Anti-human PAR-2 antibody demonstrated the presence of these receptors in eccrine sweat glands. EM showed that PAR-2 activation resulted in degranulation of secretory cells. Ca(2+) imaging using PAR-2 activators demonstrated a two phase increase in [Ca(2+)](i) which was dependent on extracellular Ca(2+) for the second phase, and that the response could be blocked by prior incubation with xestospongin, the IP(3) receptor blocker. The results demonstrated that PAR-2 receptors are present in human sweat gland secretory cells and that these receptors are functionally active and can induce changes associated with secretory events in eccrine glands.

  14. Radiofrequency Thermotherapy for Treating Axillary Hyperhidrosis.

    PubMed

    Schick, Christoph H; Grallath, Tanja; Schick, Kerstin S; Hashmonai, Moshe

    2016-05-01

    Thermotherapy has been established between conservative and surgical options as a minimally invasive method for the treatment of axillary hyperhidrosis. The objective of this study was to present radiofrequency thermotherapy (RFTT) as a safe and effective new treatment method. Thirty adult patients with pronounced axillary hyperhidrosis were treated with RFTT with noninsulated microneedles 3 times at intervals of 6 weeks. Subjective improvement was rated using the Hyperhidrosis Disease Severity Scale (HDSS) and Dermatology Life Quality Index (DLQI). Satisfaction and estimated reduction of sweating were monitored. Objective measurements were made using gravimetry. Adverse effects were recorded in follow-up. At the 6-month follow-up, improvement in sweating was seen in 27 patients. The HDSS dropped from 3.4 to 2.1, the DLQI improved significantly from 16 to 7. The gravimetric measurements of sweat were reduced from 221 to 33 mg/min. The average reduction of sweating was reported to be 72%. Adverse effects were generally mild and improved rapidly. Radiofrequency thermotherapy was shown to be an effective and minimally invasive treatment option for axillary hyperhidrosis. Patients described their sweating as normal. The method clearly has the potential to normalize axillary sweating.

  15. Feasibility and normal values of an integrated conductivity (Nanoduct™) sweat test system in healthy newborns.

    PubMed

    Kuehni, Claudia E; Schindler, Matthias; Mazur, Agnieszka; Malzacher, Andreas; Hornung, René; Barben, Juerg

    2017-07-01

    Nanoduct™ is a simple and practical sweat analysis system measuring conductivity in situ. It requires only three microlitres of sweat, making it especially applicable to newborns. We measured conductivity in 260 healthy term infants at the age of four days, and again at four weeks to determine the proportion of successful tests, test duration, and normal values for sweat conductivity in newborns. Sufficient sweat was collected in 159/260 of four-day olds (61%), and in 225/239 of four-week olds (94%). Mean (sd) test duration was 27 (5) and 25 (5) min. Mean (sd, range) conductivity was 53mmol/l (16, 8-114) at age four days, and 36 (9, 12-64) at four weeks. Determination of sweat conductivity using Nanoduct™ cannot be recommended for four-day old newborns. However, at the age of four weeks the success rate is high (94%), and conductivity values at that age are comparable to older healthy children. Copyright © 2017 European Cystic Fibrosis Society. Published by Elsevier B.V. All rights reserved.

  16. De novo epidermal regeneration using human eccrine sweat gland cells: higher competence of secretory over absorptive cells.

    PubMed

    Pontiggia, Luca; Biedermann, Thomas; Böttcher-Haberzeth, Sophie; Oliveira, Carol; Braziulis, Erik; Klar, Agnieszka S; Meuli-Simmen, Claudia; Meuli, Martin; Reichmann, Ernst

    2014-06-01

    In our previous work, we showed that human sweat gland-derived epithelial cells represent an alternative source of keratinocytes to grow a near normal autologous epidermis. The role of subtypes of sweat gland cells in epidermal regeneration and maintenance remained unclear. In this study, we compare the regenerative potential of both secretory and absorptive sweat gland cell subpopulations. We demonstrate the superiority of secretory over absorptive cells in forming a new epidermis on two levels: first, the proliferative and colony-forming efficiencies in vitro are significantly higher for secretory cells (SCs), and second, SCs show a higher frequency of successful epidermis formation as well as an increase in the thickness of the formed epidermis in the in vitro and in vivo functional analyses using a 3D dermo-epidermal skin model. However, the ability of forming functional skin substitutes is not limited to SCs, which supports the hypothesis that multiple subtypes of sweat gland epithelial cells hold regenerative properties, while the existence and exact localization of a keratinocyte stem cell population in the human eccrine sweat gland remain elusive.

  17. Comparative Study of Efficacy and Safety of Botulinum Toxin a Injections and Subcutaneous Curettage in the Treatment of Axillary Hyperhidrosis

    PubMed Central

    Budamakuntla, Leelavathy; Loganathan, Eswari; George, Anju; Revanth, BN; Sankeerth, V; Sarvjnamurthy, Sacchidananda Aradhya

    2017-01-01

    Background: Primary focal axillary hyperhidrosis is a chronic distressing disorder affecting both the sexes. When the condition is refractory to conservative management, we should go for more promising therapies like intradermal botulinum toxin A (BtxA) injections in the axilla, and surgical therapies like subcutaneous curettage of sweat glands. Aims and Objectives: The aim of this study is to compare the efficacy, safety and duration of action of intradermal BtxA injections in one axilla and subcutaneous curettage of sweat glands in the other axilla of the same patient with axillary hyperhidrosis. Materials and Methods: Twenty patients (40 axillae) received intradermal BtxA injections on the right side (20 axillae) and underwent tumescent subcutaneous curettage of sweat glands on the left side (20 axillae). Sweat production rate was measured using gravimetry analyses at baseline and at 3 months after the procedure. Subjective analyses were done using hyperhidrosis disease severity scale (HDSS) score at baseline, at 3rd and 6th month after the procedure. Results: At 3 months post-treatment, the resting sweat rate in the toxin group improved by 80.32% versus 79.79% in the subcutaneous curettage method (P = 0.21). Exercise-induced sweat rate in the toxin group improved by 88.76% versus 88.8% in the subcutaneous curettage group (P = 0.9). There was a significant difference in the HDSS score after treatment with both the modalities. There were no adverse events with BtxA treatment compared to very minor adverse events with the surgical method. Conclusion: Both intradermal BtxA injections and tumescent subcutaneous curettage of sweat glands had a significant decrease in the sweat rates with no significant difference between the two modalities. Hence, in resource poor settings where affordability of BtxA injection is a constraint, subcutaneous curettage of sweat glands can be preferred which has been found equally effective with no or minimal adverse events. PMID:28529419

  18. Cannabis Use Surveillance by Sweat Analysis.

    PubMed

    Gambelunghe, Cristiana; Fucci, Nadia; Aroni, Kyriaki; Bacci, Mauro; Marcelli, Antonio; Rossi, Riccardo

    2016-10-01

    Sweat testing, an alternative matrix for establishing drug abuse, offers additional benefits to the more common biological samples. The authors developed a procedure using gas chromatography-mass spectrometry to test for Δ9-tetrahydrocannabinol, 11-nor-Δ9-tetrahydrocannabinol-9-carboxylic acid, cannabinol (CBN), and cannabidiol (CBD) in a sweat patch. The results were compared with urine and hair sample results. Urine, hair, and sweat samples were simultaneously collected from 12 patients who were involved, respectively, in forensic case and monitoring abuse. Selectivity, linearity, limit of detection (LOD), limit of quantification (LOQ), recovery, intraday and interday imprecision, and inaccuracy of the quantification procedure were validated. LODs in hair were 0.05 ng/mg for Δ9-tetrahydrocannabinol, CBN, and CBD, and 0.005 ng/mg for 11-nor-Δ9-tetrahydrocannabinol-9-carboxylic acid. The LOD for sweat was 0.30 ng/patch for all substances. The LOQ in hair was 0.1 ng/mg for Δ9-tetrahydrocannabinol, CBN, and CBD, and 0.01 ng/mg for 11-nor-Δ9-tetrahydrocannabinol-9-carboxylic acid. The LOQ was 0.4 ng/patch in sweat for each analyte. Cannabinoid in urine was determined by means of immunochemical screening (cutoff 11-nor-Δ-tetrahydrocannabinol-9-carboxylic acid 50 ng/mL). All subjects tested positive for 11-nor-Δ9-tetrahydrocannabinol-9-carboxylic acid and Δ9-tetrahydrocannabinol in urine and hair. In sweat samples, Δ9-tetrahydrocannabinol was found in all patches (0.4-2.0 ng/patch); 6 cases were positive for CBN (0.4-0.5 ng/patch) and 3 for CBD (0.4-0.6 ng/patch); 11-nor-Δ9-tetrahydrocannabinol-9-carboxylic acid was never detected in patches. Present sweat analysis results integrated the information from hair and urine and showed that sweat analysis is a suitable, noninvasive method for monitoring compliance with rehabilitation therapy and for detecting recent cumulative use of cannabinoids.

  19. Sources of Variation in Sweat Chloride Measurements in Cystic Fibrosis.

    PubMed

    Collaco, Joseph M; Blackman, Scott M; Raraigh, Karen S; Corvol, Harriet; Rommens, Johanna M; Pace, Rhonda G; Boelle, Pierre-Yves; McGready, John; Sosnay, Patrick R; Strug, Lisa J; Knowles, Michael R; Cutting, Garry R

    2016-12-01

    Expanding the use of cystic fibrosis transmembrane conductance regulator (CFTR) potentiators and correctors for the treatment of cystic fibrosis (CF) requires precise and accurate biomarkers. Sweat chloride concentration provides an in vivo assessment of CFTR function, but it is unknown the degree to which CFTR mutations account for sweat chloride variation. To estimate potential sources of variation for sweat chloride measurements, including demographic factors, testing variability, recording biases, and CFTR genotype itself. A total of 2,639 sweat chloride measurements were obtained in 1,761 twins/siblings from the CF Twin-Sibling Study, French CF Modifier Gene Study, and Canadian Consortium for Genetic Studies. Variance component estimation was performed by nested mixed modeling. Across the tested CF population as a whole, CFTR gene mutations were found to be the primary determinant of sweat chloride variability (56.1% of variation) with contributions from variation over time (e.g., factors related to testing on different days; 13.8%), environmental factors (e.g., climate, family diet; 13.5%), other residual factors (e.g., test variability; 9.9%), and unique individual factors (e.g., modifier genes, unique exposures; 6.8%) (likelihood ratio test, P < 0.001). Twin analysis suggested that modifier genes did not play a significant role because the heritability estimate was negligible (H 2  = 0; 95% confidence interval, 0.0-0.35). For an individual with CF, variation in sweat chloride was primarily caused by variation over time (58.1%) with the remainder attributable to residual/random factors (41.9%). Variation in the CFTR gene is the predominant cause of sweat chloride variation; most of the non-CFTR variation is caused by testing variability and unique environmental factors. If test precision and accuracy can be improved, sweat chloride measurement could be a valuable biomarker for assessing response to therapies directed at mutant CFTR.

  20. Sources of Variation in Sweat Chloride Measurements in Cystic Fibrosis

    PubMed Central

    Blackman, Scott M.; Raraigh, Karen S.; Corvol, Harriet; Rommens, Johanna M.; Pace, Rhonda G.; Boelle, Pierre-Yves; McGready, John; Sosnay, Patrick R.; Strug, Lisa J.; Knowles, Michael R.; Cutting, Garry R.

    2016-01-01

    Rationale: Expanding the use of cystic fibrosis transmembrane conductance regulator (CFTR) potentiators and correctors for the treatment of cystic fibrosis (CF) requires precise and accurate biomarkers. Sweat chloride concentration provides an in vivo assessment of CFTR function, but it is unknown the degree to which CFTR mutations account for sweat chloride variation. Objectives: To estimate potential sources of variation for sweat chloride measurements, including demographic factors, testing variability, recording biases, and CFTR genotype itself. Methods: A total of 2,639 sweat chloride measurements were obtained in 1,761 twins/siblings from the CF Twin-Sibling Study, French CF Modifier Gene Study, and Canadian Consortium for Genetic Studies. Variance component estimation was performed by nested mixed modeling. Measurements and Main Results: Across the tested CF population as a whole, CFTR gene mutations were found to be the primary determinant of sweat chloride variability (56.1% of variation) with contributions from variation over time (e.g., factors related to testing on different days; 13.8%), environmental factors (e.g., climate, family diet; 13.5%), other residual factors (e.g., test variability; 9.9%), and unique individual factors (e.g., modifier genes, unique exposures; 6.8%) (likelihood ratio test, P < 0.001). Twin analysis suggested that modifier genes did not play a significant role because the heritability estimate was negligible (H2 = 0; 95% confidence interval, 0.0–0.35). For an individual with CF, variation in sweat chloride was primarily caused by variation over time (58.1%) with the remainder attributable to residual/random factors (41.9%). Conclusions: Variation in the CFTR gene is the predominant cause of sweat chloride variation; most of the non-CFTR variation is caused by testing variability and unique environmental factors. If test precision and accuracy can be improved, sweat chloride measurement could be a valuable biomarker for assessing response to therapies directed at mutant CFTR. PMID:27258095

Top