Sample records for swimming pool reactors

  1. BUILDING FOR THE EXPERIMENTAL SWIMMING POOL REACTOR OF 3Mw OF THE JUNTA DE ENERGIA NUCLEAR (in Spanish)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    de la Camara, S.N.

    1958-10-01

    The Spanish experimental swimming pool reactor is constructed on the grounds of the Ciudad Universitaria de Madrid. A general layout of the reactor building and its annexes is given, and the reactor building itself is described. The construction of the reactor building and the characteristics of the annex building are discussed. (J.S.R.)

  2. Thermos reactors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Labrousse, M.; Lerouge, B.; Dupuy, G.

    1978-04-01

    THERMOS is a water reactor designed to provide hot water up to 120/sup 0/C for district heating or for desalination applications. It is a 100-MW reactor based on proven technology: oxide fuel plate elements, integrated primary circuit, and reactor vessel located in the bottom of a pool. As in swimming pool reactors, the pool is used for biological shielding, emergency core cooling, and fission product filtering (in case of an accident). Before economics, safety is the main characteristic of the concept: no fuel failure admitted, core under water in any accidental configuration, inspection of every ''nuclear'' component, and double-wall containment.

  3. NUCLEAR REACTOR CONTROL SYSTEM

    DOEpatents

    Epler, E.P.; Hanauer, S.H.; Oakes, L.C.

    1959-11-01

    A control system is described for a nuclear reactor using enriched uranium fuel of the type of the swimming pool and other heterogeneous nuclear reactors. Circuits are included for automatically removing and inserting the control rods during the course of normal operation. Appropriate safety circuits close down the nuclear reactor in the event of emergency.

  4. Utilization of the Philippine Research Reactor as a training facility for nuclear power plant operators

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Palabrica, R.J.

    1981-01-01

    The Philippines has a 1-MW swimming-pool reactor facility operated by the Philippine Atomic Energy Commission (PAEC). The reactor is light-water moderated and cooled, graphite reflected, and fueled with 90% enriched uranium. Since it became critical in 1963 it has been utilized for research, radioisotope production, and training. It was used initially in the training of PAEC personnel and other research institutions and universities. During the last few years, however, it has played a key role in training personnel for the Philippine Nuclear Power Project (PNPP).

  5. JEN-1 Reactor Control System; SISTEMA DE CONTROL DEL REACTOR JEN-1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cantillo, M.F.; Nuno, C.M.; Andreu, J.L.M.

    1963-01-01

    ABS>The JEN-1 3Mw power swimming pool reactor electrical control circuits are described. Start-up, power generation in the core, and shutdown are controlled by the reactor control system. This control system guarantees in each moment the safety conditions during reactor operation. Each circuit was represented by a scheme, complemented with a description of its function, components, and operation theory. Components described include: scram circuit; fission counter control circuit; servo control circuit; control circuit of safety sheets; control circuits of primary, secondary, and clean-up pump motors and tower fan motor; primary valve motor circuit; center cubicle alarm circuit; and process alarm circuit.more » (auth)« less

  6. Pore diffusion limits removal of monochloramine in treatment of swimming pool water using granular activated carbon.

    PubMed

    Skibinski, Bertram; Götze, Christoph; Worch, Eckhard; Uhl, Wolfgang

    2018-04-01

    Overall apparent reaction rates for the removal of monochloramine (MCA) in granular activated carbon (GAC) beds were determined using a fixed-bed reactor system and under conditions typical for swimming pool water treatment. Reaction rates dropped and quasi-stationary conditions were reached quickly. Diffusional mass transport in the pores was shown to be limiting the overall reaction rate. This was reflected consistently in the Thiele modulus, in the effect of temperature, pore size distribution and of grain size on the reaction rates. Pores <2.5 times the diameter of the monochloramine molecule were shown to be barely accessible for the monochloramine conversion reaction. GACs with a significant proportion of large mesopores were found to have the highest overall reactivity for monochloramine removal. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. 1968 Listing of Swimming Pool Equipment.

    ERIC Educational Resources Information Center

    National Sanitation Foundation, Ann Arbor, MI. Testing Lab.

    An up-to-date listing of swimming pool equipment including--(1) companies authorized to display the National Sanitation Foundation seal of approval, (2) equipment listed as meeting NSF swimming pool equipment standards relating to diatomite type filters, (3) equipment listed as meeting NSF swimming pool equipment standard relating to sand type…

  8. Automation of water supply and recirculation-filtration of water at a swimming pool using Zelio PLC

    NASA Astrophysics Data System (ADS)

    Diniş, C. M.; Popa, G. N.; Iagăr, A.

    2018-01-01

    The paper proposes the use of the Zelio PLC for the automation of the water supply and recirculation-filtration system of a swimming pool. To do this, the Zelio SR3B261BD - 24V DC with 10 digital inputs (24V DC) and 10 digital outputs (relay contacts) was used. The proposed application makes the control of the water supply pumps and the water recirculation-filtration from a swimming pool. The recirculation-filtration systems for pools and swimming pools are designed to ensure water cleaning and recirculation to achieve optimum quality and lasting service life. The water filtration process is one of the important steps in water treatment in polls and swimming pools. It consists in recirculation of the entire volume of water and begins by absorbing the water in the pool by means of a pump followed by the passing of water through the filter, disinfectant and pH dosing, and reintroducing the water back into the pool or swimming pool through the discharge holes. Filters must to work 24 hours a day to remove pollutants from pools or swimming pools users. Filtration removes suspension particles with different origins. All newly built pools and swimming pools must be fitted with water recirculation systems, and existing ones will be equipped with water recirculation and water treatment systems.

  9. [Legal and management issues of public health requirements for swimming pools in Regione Toscana].

    PubMed

    Linguanti, Saverio; Totaro, Michele; Frendo, Lorenzo; Giorgi, Serena; Porretta, Andrea; Valentini, Paola; Baggiani, Angelo

    2018-01-01

    In this paper we describe the laws and rules applying to swimming pools. Authorization activity title for recreational swimming pools is regulated according to articles 80 and 86 of the TULPS R.D.n°773/1931. In Regione Toscana periodic management of the hygienic requirements for swimming pools is regulated by Regional Decree 54R/2015. It requires the evaluation of physical-chemical and microbiological indicators. The law applies to structural and organizational requirements of swimming pools as well as defines responsabilities of managers.

  10. Increased Risk of Tinea Pedis and Onychomycosis Among Swimming Pool Employees in Netanya Area, Israel.

    PubMed

    Shemer, Avner; Gupta, Aditya K; Amichai, Boaz; Baum, Sharon; Barzilai, Aviv; Farhi, Renata; Kaplan, Yehonathan; MacLeod, Melissa A

    2016-12-01

    Tinea pedis and onychomycosis often co-occur in individuals. A relationship between swimming pools and tinea pedis exists; however, little research has investigated the relationship between onychomycosis, tinea pedis, and swimming pools. This study sought to examine the prevalence of tinea pedis and onychomycosis among swimming pool employees, a population that may be at risk of tinea infections. Samples were taken from 169 employees at 21 swimming pools in the Netanya area, Israel. KOH microscopy and culture was used to identify fungi. About 46 % of swimming pool employees had concurrent tinea pedis and onychomycosis, 30 % had tinea pedis only, and 6 % had onychomycosis only, compared to 10, 8, and 8 % of controls, respectively. After adjusting for age and gender, swimming pool employees were 20× more likely to have concurrent tinea pedis and onychomycosis, 15× more likely to have tinea pedis only, and 3× more likely to have onychomycosis only compared to controls. The present results are in agreement with previous research and support that swimming pools remain an important source of fungal contamination. More attention to hygienic guidelines and preventative measures may be needed in these settings.

  11. Swimming pool granuloma

    MedlinePlus

    ... this page: //medlineplus.gov/ency/article/001357.htm Swimming pool granuloma To use the sharing features on this page, please enable JavaScript. A swimming pool granuloma is a long-term (chronic) skin ...

  12. Molluscum Contagiosum

    MedlinePlus

    ... pit in the center. Molluscum Contagiosum in Special Environments Swimming Pools Day Care Centers and Schools At ... Risk Factors Treatment Prevention Long-Term Effects Special Environments Swimming Pools Swimming Pool Safety Recommendations Day Care ...

  13. DROWNING IN DISINFECTION BY-PRODUCTS? SWIMMING POOL WATER QUALITY RECONSIDERED.

    EPA Science Inventory

    The development of treated water for swimming pools has made swimming a year ¬round activity, widely enjoyed for leisure as well as exercise. Swimming pools can be found in different kinds and sizes in public areas, hotels and spas, or at private homes. In Germany ~250-300 millio...

  14. DROWNING IN DISINFECTION BY-PRODUCTS? ASSESSING SWIMMING POOL WATER

    EPA Science Inventory

    The development of treated water for swimming pools has made swimming a year round activity, widely enjoyed for leisure as well as exercise. Swimming pools can be found in different kinds and sizes in public areas, hotels and spas, or at private homes. In Germany ~250-300 million...

  15. Swimming pool cleaner poisoning

    MedlinePlus

    Swimming pool cleaner poisoning occurs when someone swallows this type of cleaner, touches it, or breathes in ... The harmful substances in swimming pool cleaner are: Bromine ... copper Chlorine Soda ash Sodium bicarbonate Various mild acids

  16. 3. SWIMMING POOL. VIEW TO SOUTHEAST. Rainbow Hydroelectric Facility, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    3. SWIMMING POOL. VIEW TO SOUTHEAST. - Rainbow Hydroelectric Facility, Swimming Pool, On north bank of Missouri River 2 miles Northeast of Great Falls, & end of Rainbow Dam Road, Great Falls, Cascade County, MT

  17. 1. SWIMMING POOL. VIEW TO WEST. Rainbow Hydroelectric Facility, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    1. SWIMMING POOL. VIEW TO WEST. - Rainbow Hydroelectric Facility, Swimming Pool, On north bank of Missouri River 2 miles Northeast of Great Falls, & end of Rainbow Dam Road, Great Falls, Cascade County, MT

  18. 2. SWIMMING POOL. VIEW TO SOUTHEAST. Rainbow Hydroelectric Facility, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    2. SWIMMING POOL. VIEW TO SOUTHEAST. - Rainbow Hydroelectric Facility, Swimming Pool, On north bank of Missouri River 2 miles Northeast of Great Falls, & end of Rainbow Dam Road, Great Falls, Cascade County, MT

  19. Benefits of carbon dioxide as pH reducer in chlorinated indoor swimming pools.

    PubMed

    Gomà, Anton; Guisasola, Albert; Tayà, Carlota; Baeza, Juan A; Baeza, Mireia; Bartrolí, Albert; Lafuente, Javier; Bartrolí, Jordi

    2010-06-01

    Carbon dioxide is seldom used as pH reducer in swimming pools. Nevertheless it offers two interesting advantages. First, its use instead of the usual hydrochloric acid avoids the characteristic and serious accident of mixing the disinfectant with that strong acid, which forms a dangerous chlorine gas cloud and, second, it allows the facility to become slightly a depository of that greenhouse gas. This work introduces the experience of using CO(2) as pH reducer in real working swimming pools, showing three more advantages: lower chlorine consumption, lower presence of oxidants in the air above the swimming pool and a diminished formation of trihalomethanes in the swimming pool water. Experiments lasted 4years and they were run in three swimming pools in the Barcelona area, where the conventional system based upon HCl and a system based upon CO(2) were consecutively exchanged.

  20. The R/D of high power proton accelerator technology in China

    NASA Astrophysics Data System (ADS)

    Xialing, Guan

    2002-12-01

    In China, a multipurpose verification system as a first phase of our ADS program consists of a low energy accelerator (150 MeV/3 mA proton LINAC) and a swimming pool light water subcritical reactor. In this paper the activities of HPPA technology related to ADS in China, which includes the intense proton ECR source, the RFQ accelerator and some other technology of HPPA, are described.

  1. VIEW OF OUTDOOR SWIMMING POOL AND FILTER ROOM/ BATHHOUSE S196, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    VIEW OF OUTDOOR SWIMMING POOL AND FILTER ROOM/ BATHHOUSE S-196, FACING WEST. - U.S. Naval Base, Pearl Harbor, Outdoor Swimming Pool, Corner of Liscome Bay Street & St. Lo Avenue, Pearl City, Honolulu County, HI

  2. Comprehensive Identification of Chemical DBPs from Chlorinated and Brominated Swimming Pools

    EPA Science Inventory

    Swimming pools have been recently recognized as important routes of exposure to potentially harmful chemicals. Previous epidemiologic research has shown increased incidence of asthma and other respiratory effects for people who have significant indoor swimming pool exposures, an...

  3. 3. View to northwest showing swimming pool, filtration/chlorination building (at ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    3. View to northwest showing swimming pool, filtration/chlorination building (at left), and southeast elevation of Carpenter & Paint Shop (HABS No. VA-1287-L, at rear) - Portsmouth Naval Hospital, Shower Room & Swimming Pool, Green Street, Portsmouth, Portsmouth, VA

  4. Swimming Pools for Schools.

    ERIC Educational Resources Information Center

    Neilson, Donald W.; Nixon, John E.

    The increasing interest in swimming instruction and recreation for elementary and secondary school children has resulted in the development of this guide for swimming pool use, design, and construction. Introductory material discussed the need for swimming in the educational program and the organization of swimming programs in the school. Design…

  5. Life cycle environmental implications of residential swimming pools.

    PubMed

    Forrest, Nigel; Williams, Eric

    2010-07-15

    Ownership of private swimming pools in the U.S. grew 2 to 4% per annum from 1997 to 2007. The environmental implications of pool ownership are analyzed by hybrid life cycle assessment (LCA) for nine U.S. cities. An operational model is constructed estimating consumption of chemicals, water, and energy for a typical residential pool. The model incorporates geographical climatic variations and upstream water and energy use from electricity and water supply networks. Results vary considerably by city: a factor of 5-6 for both water and energy use. Water use is driven by aridness and length of the swimming season, while energy use is mainly driven by length of the swimming season. Water and energy impacts of pools are significant, particularly in arid climates. In Phoenix for example pools account for 22% and 13% of a household's electricity and water use, respectively. Measures to reduce water and energy use in pools such as optimizing the pump schedule and covering the pool in winter can realize greater savings than many common household efficiency improvements. Private versus community pools are also compared. Community pools in Phoenix use 60% less swimming pool water and energy per household than subdivisions without community pools.

  6. 16 CFR 1207.12 - Stockpiling.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... STANDARD FOR SWIMMING POOL SLIDES § 1207.12 Stockpiling. (a) Definitions. As used in this section: (1) Stockpiling means manufacturing or importing swimming pool slides between the date of promulgation of part... importation) means the total number of swimming pool slides manufactured (or imported) during a stated time...

  7. Evaluation and Treatment of Swimming Pool Avoidance Exhibited by an Adolescent Girl with Autism

    ERIC Educational Resources Information Center

    Rapp, John T.; Vollmer, Timothy R.; Hovanetz, Alyson N.

    2005-01-01

    We evaluated and treated swimming pool avoidance that was exhibited by a 14-year-old girl diagnosed with autism. In part, treatment involved blocking for flopping (dropping to the ground) and elopement (running away from the pool) and access to food for movements toward a swimming pool. Treatment also involved reinforcement for exposure to various…

  8. 16 CFR 1207.1 - Scope, purpose, and findings.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... SAFETY STANDARD FOR SWIMMING POOL SLIDES § 1207.1 Scope, purpose, and findings. (a) Scope and purpose... Commission for the manufacture and construction of slides for use in swimming pools. The requirements of this... swimming pool slides. This standard also makes certain recommendations regarding the installation...

  9. Genotoxic Effects in Swimmers Exposed to Disinfection By-products in Indoor Swimming Pool

    EPA Science Inventory

    BACKGROUND: Exposure to disinfection by-products (DBPs) in drinking water has been associated with cancer risk, and a recent study found an increased bladder cancer risk among subjects attending swimming pools. OBJECTIVES: To evaluate whether swimming in pools is associated with ...

  10. Healthy Swimming/Recreational Water

    MedlinePlus

    ... the Pool Raccoons & Pools Birds & Pools Aquatics Professionals Design & Construction Designing Public Swimming Facilities Historic CDC Design & Operation Manuals Operation & Maintenance 12 Steps for Prevention ...

  11. Genotoxic Effects in Swimmers Exposed to Disinfection By-products in Indoor Swimming Pools

    PubMed Central

    Kogevinas, Manolis; Villanueva, Cristina M.; Font-Ribera, Laia; Liviac, Danae; Bustamante, Mariona; Espinoza, Felicidad; Nieuwenhuijsen, Mark J.; Espinosa, Aina; Fernandez, Pilar; DeMarini, David M.; Grimalt, Joan O.; Grummt, Tamara; Marcos, Ricard

    2010-01-01

    Background Exposure to disinfection by-products (DBPs) in drinking water has been associated with cancer risk. A recent study (Villanueva et al. 2007; Am J Epidemiol 165:148–156) found an increased bladder cancer risk among subjects attending swimming pools relative to those not attending. Objectives We evaluated adults who swam in chlorinated pools to determine whether exposure to DBPs in pool water is associated with biomarkers of genotoxicity. Methods We collected blood, urine, and exhaled air samples from 49 nonsmoking adult volunteers before and after they swam for 40 min in an indoor chlorinated pool. We estimated associations between the concentrations of four trihalomethanes (THMs) in exhaled breath and changes in micronuclei (MN) and DNA damage (comet assay) in peripheral blood lymphocytes before and 1 hr after swimming; urine mutagenicity (Ames assay) before and 2 hr after swimming; and MN in exfoliated urothelial cells before and 2 weeks after swimming. We also estimated associations and interactions with polymorphisms in genes related to DNA repair or to DBP metabolism. Results After swimming, the total concentration of the four THMs in exhaled breath was seven times higher than before swimming. The change in the frequency of micronucleated lymphocytes after swimming increased in association with higher exhaled concentrations of the brominated THMs (p = 0.03 for bromodichloromethane, p = 0.05 for chlorodibromomethane, p = 0.01 for bromoform) but not chloroform. Swimming was not associated with DNA damage detectable by the comet assay. Urine mutagenicity increased significantly after swimming, in association with the higher concentration of exhaled bromoform (p = 0.004). We found no significant associations with changes in micronucleated urothelial cells. Conclusions Our findings support potential genotoxic effects of exposure to DBPs from swimming pools. The positive health effects gained by swimming could be increased by reducing the potential health risks of pool water. PMID:20833606

  12. Deep Trouble.

    ERIC Educational Resources Information Center

    Fawcett, Paul

    1997-01-01

    Discusses how accident prevention can be built into the swimming-pool design phase by paying attention to swimming-pool regulations, materials for basin and deck construction, pool-fixture placement, and signs and markings. A pool planning checklist is provided. (GR)

  13. Swimming Pools.

    ERIC Educational Resources Information Center

    Ministry of Housing and Local Government, London (England).

    Technical and engineering data are set forth on the design and construction of swimming pools. Consideration is given to site selection, pool construction, the comparative merits of combining open air and enclosed pools, and alternative uses of the pool. Guidelines are presented regarding--(1) pool size and use, (2) locker and changing rooms, (3)…

  14. Swimming Pools. A Guide to Their Planning, Design and Operation.

    ERIC Educational Resources Information Center

    Gabrielsen, M. Alexander, Ed.

    Information is presented regarding all phases of swimming pool development and operation from earliest planning considerations to final programing. This comprehensive book covers--(1) the steps involved in planning a pool, (2) designing the pool, (3) water circulation, filtration, and treatment, (4) community pools, school and agency pools, and…

  15. Potential risks of TiO2 and ZnO nanoparticles released from sunscreens into outdoor swimming pools.

    PubMed

    Jeon, Soo-Kyung; Kim, Eun-Ju; Lee, Jaesang; Lee, Seunghak

    2016-11-05

    The potential risks of nanoparticles (NPs) in sunscreens being released into swimming water were evaluated by a series of laboratory experiments simulating the fate and transport of NPs in outdoor swimming pools. NPs released from sunscreen-applied skin were estimated using pig skins covered with five different commercial sunscreens containing TiO2, ZnO, or both at various concentrations. Assuming that the swimming water treatment processes consisted of filtration, UV irradiation, heating, and chlorination, possible removal of the released NPs by each process was estimated. Generation of hydrogen peroxide (H2O2) by the NPs under sunlight and after UV photochemical treatment were measured, and the H2O2 concentration possibly present in the swimming pool was calculated based on some specific scenarios of operating an outdoor swimming pool. It was found that a significant amount of the NPs in sunscreens could be released into the swimming water, and accumulate during circulation through the treatment system. However, the concentration of H2O2 possibly present in the swimming pool should be below the level at which an adverse effect to bathers is concerned. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. The Good, the Bad, and the Volatile - Can We Have Both Healthy Pools and Healthy People?

    EPA Science Inventory

    Given the popularity of swimming for recreation and sport, it is remarkable that we are only in the early stages of understanding swimming pool chemistry, human exposure(s), and potential health risks. This is partly due to the complexity of swimming pool water chemistry, which i...

  17. RECESSED AUTOMATIC SURFACE SKIMMERS FOR SWIMMING POOLS. NATIONAL SANITATION FOUNDATION STANDARD NUMBER 11.

    ERIC Educational Resources Information Center

    National Sanitation Foundation, Ann Arbor, MI.

    THE NATIONAL SANITATION FOUNDATION STANDARD ON SWIMMING POOL EQUIPMENT CONCERNS ITSELF WITH THE SUCCESSFUL APPLICATION OF SURFACE SKIMMERS TO SWIMMING POOLS. THE MINIMUM DESIGN AND CONSTRUCTION REQUIREMENTS ESTABLISHED BY THIS STANDARD ARE SET FORTH TO PROVIDE A MEANS OF EVALUATING THE OVERALL CONSTRUCTION AND EFFECTIVENESS OF THE UNIT. ADDITIONAL…

  18. 26 CFR 1.856-6 - Foreclosure property.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... as, for example, an outdoor swimming pool or a parking garage) may be considered to be an integral... wings, an access road, a parking lot, and an outdoor swimming pool planned for the motel were each less... parking lot, and the swimming pool: Provided, That the motel and the other improvements which the trust...

  19. Study on water evaporation rate from indoor swimming pools

    NASA Astrophysics Data System (ADS)

    Rzeźnik, Ilona

    2017-11-01

    The air relative humidity in closed spaces of indoor swimming pools influences significantly on users thermal comfort and the stability of the building structure, so its preservation on suitable level is very important. For this purpose, buildings are equipped with HVAC systems which provide adequate level of humidity. The selection of devices and their technical parameters is made using the mathematical models of water evaporation rate in the unoccupied and occupied indoor swimming pool. In the literature, there are many papers describing this phenomena but the results differ from each other. The aim of the study was the experimental verification of published models of evaporation rate in the pool. The tests carried out on a laboratory scale, using model of indoor swimming pool, measuring 99cm/68cm/22cm. The model was equipped with water spray installation with six nozzles to simulate conditions during the use of the swimming pool. The measurements were made for conditions of sports pools (water temperature 24°C) and recreational swimming pool (water temperature 34°C). According to the recommendations the air temperature was about 2°C higher than water temperature, and the relative humidity ranged from 40% to 55%. Models Shah and Biasin & Krumm were characterized by the best fit to the results of measurements on a laboratory scale.

  20. Water ingestion during swimming activities in a pool: a pilot study.

    PubMed

    Dufour, Alfred P; Evans, Otis; Behymer, Thomas D; Cantú, Ricardo

    2006-12-01

    Chloroisocyanurates are commonly added to outdoor swimming pools to stabilize chlorine disinfectants. The chloroisocyanurates decompose slowly to release chlorine and cyanuric acid. Studies conducted to determine if the chloroisocyanurates might be toxic to swimmers showed that they were not and that ingested cyanuric acid passed through the body unmetabolized. This fact was used to determine the amount of water swallowed during swimming activity. Fifty-three recreational swimmers, using a community swimming pool disinfected with cyanuric acid stabilized chlorine, participated in the study. The participants did not swim on the day before or after the test swim. The swimmers were asked to actively swim for at least 45 minutes and to collect their urine for the next 24 hours. Cyanuric acid was measured in pool water using high performance liquid chromatography and porous graphitic carbon columns with UV detection. The urine sample assay required a clean-up procedure to remove urinary proteins and interfering substances. Results of the study indicate that non-adults ingest about twice as much water as adults during swimming activity. The average amount of water swallowed by non-adults and adults was 37 ml and 16 ml, respectively. The design for this study and the analytical methodology used to assay cyanuric acid in swimming pool water and human urine were effective for measuring the volume of water swallowed during swimming activity.

  1. Limiting swimming pool outbreaks of cryptosporidiosis - the roles of regulations, staff, patrons and research.

    PubMed

    Ryan, Una; Lawler, Sheleigh; Reid, Simon

    2017-02-01

    Cryptosporidium is the leading cause of swimming pool outbreaks of gastroenteritis. Transmission occurs through the ingestion of oocysts that are passed in the faeces of an infected person or animal when an accidental faecal release event occurs. Cryptosporidium parasites present specific challenges for infection control as oocysts are highly resistant to chlorine levels used for pool disinfection, infected individuals can shed large numbers of oocysts, there is a long incubation period and shedding of oocysts occurs even after symptom resolution. The purposes of this review are to identify key barriers to limiting swimming pool-associated outbreaks of cryptosporidiosis and to outline needs for research and collaboration to advance co-ordinated management practices. We reviewed swimming pool-associated cryptosporidiosis outbreaks, disinfection teachniques, current regulations and the role of staff and patrons. Key barriers to limiting swimming pool-associated outbreaks of cryptosporidiosis are a lack of uniform national and international standards, poor adherence and understanding of regulations governing staff and patron behaviour, and low levels of public knowledge and awareness.

  2. Variability of chlorination by-product occurrence in water of indoor and outdoor swimming pools.

    PubMed

    Simard, Sabrina; Tardif, Robert; Rodriguez, Manuel J

    2013-04-01

    Swimming is one of the most popular aquatic activities. Just like natural water, public pool water may contain microbiological and chemical contaminants. The purpose of this study was to study the presence of chemical contaminants in swimming pools, in particular the presence of disinfection by-products (DBPs) such as trihalomethanes (THMs), haloacetic acids (HAAs) and inorganic chloramines (CAMi). Fifty-four outdoor and indoor swimming pools were investigated over a period of one year (monthly or bi-weekly sampling, according to the type of pool) for the occurrence of DBPs. The results showed that DBP levels in swimming pools were greater than DBP levels found in drinking water, especially for HAAs. Measured concentrations of THMs (97.9 vs 63.7 μg/L in average) and HAAs (807.6 vs 412.9 μg/L in average) were higher in outdoor pools, whereas measured concentrations of CAMi (0.1 vs 0.8 mg/L in average) were higher in indoor pools. Moreover, outdoor pools with heated water contained more DBPs than unheated pools. Finally, there was significant variability in tTHM, HAA9 and CAMi levels in pools supplied by the same municipal drinking water network, suggesting that individual pool characteristics (number of swimmers) and management strategies play a major role in DBP formation. Copyright © 2012 Elsevier Ltd. All rights reserved.

  3. Swimming Pools. Managing School Facilities, Guide 2.

    ERIC Educational Resources Information Center

    Department for Education and Employment, London (England). Architects and Building Branch.

    This guide for schools with swimming pools offers advice concerning appropriate training for pool managers, the importance of water quality and testing, safety in the handling of chemicals, maintenance and cleaning requirements, pool security, and health concerns. The guide covers both indoor and outdoor pools, explains some technical terms,…

  4. Exciting Pools

    ERIC Educational Resources Information Center

    Wright, Bradford L.

    1975-01-01

    Advocates the creation of swimming pool oscillations as part of a general investigation of mechanical oscillations. Presents the equations, procedure for deriving the slosh modes, and methods of period estimation for exciting swimming pool oscillations. (GS)

  5. Pool Safety: A Few Simple Rules.

    ERIC Educational Resources Information Center

    PTA Today, 1993

    1993-01-01

    Presents suggestions by the National Swimming Pool Safety Committee on how to keep children safe while swimming. Ideas include maintaining strict adult supervision, pool and spa barriers, and knowledge of cardiopulmonary resuscitation. (SM)

  6. Effect of the starting and turning performances on the subsequent swimming parameters of elite swimmers.

    PubMed

    Veiga, Santiago; Roig, Andreu

    2017-03-01

    In the present research, we examined the effect of the starting and turning performances on the subsequent swimming parameters by (1) comparing the starting and turning velocities with the swimming parameters on the emersion and mid-pool segments and (2) by relating the individual behaviour of swimmers during the start and turns with subsequent behaviour on each swimming lap. One hundred and twelve 100 m performances on the FINA 2013 World Swimming Championships were analysed by an image-processing system (InThePool 2.0®). At the point of the start emersion, the swimming parameters of the 100-m elite swimmers were substantially greater than the mid-pool parameters, except on the breaststroke races. On the other hand, no diminution in the swimming parameters was observed between the turn emersion and the mid-pool swimming, except on the butterfly and backstroke male races. Changes on the surface swimming kinematics were not generally related to the starting or turning parameters, although male swimmers who develop faster starts seem to achieve faster velocities at emersion. Race analysts should be aware of a transfer of momentum when swimmers emerge from underwater with implications on the subsequent swimming kinematics, especially for male swimmers who employ underwater undulatory techniques.

  7. Swimming Lessons: Learning, New Materialisms, Posthumanism, and Post Qualitative Research Emerge through a Pool Poem

    ERIC Educational Resources Information Center

    McKnight, Lucinda

    2016-01-01

    This article shifts from the formal learning spaces of school and university to an Australian public swimming pool to playfully engage some of the dilemmas that recent theory poses for curriculum studies. The article enacts multiple diffractions (Barad, 2007) as theory becomes swimming and swimming becomes theory, and ideas and movements are…

  8. Solar-heated municipal swimming pools, a case study: Dade County, Florida

    NASA Astrophysics Data System (ADS)

    Levin, M.

    1981-09-01

    The installation of a solar energy system to heat the water in the swimming pool in one of Dade County, Florida's major parks is described. The mechanics of solar heated swimming pools are explained. The solar heating system consists of 216 unglazed polypropylene tube collectors, a differential thermostat, and the distribution system. The systems performance and economics as well as future plants are discussed.

  9. Swimming attendance during childhood and development of asthma: Meta-analysis.

    PubMed

    Valeriani, Federica; Protano, Carmela; Vitali, Matteo; Romano Spica, Vincenzo

    2017-05-01

    The association between asthma and swimming pool attendance has not been demonstrated and currently there are conflicting results. In order to clarify the association between asthma diagnosis in children and swimming pool attendance, and to assess the consistency of the available epidemiological studies, we completed a literature analysis on the relationship between the exposure to disinfection by-products in indoor swimming pools during childhood and asthma diagnosis. Following the Meta-analysis of Observational Studies in Epidemiology (MOOSE) and Preferred Reporting Items for Systematic reviews and Meta-Analyses (PRISMA) criteria, a systematic review and meta-analysis was performed by searching MEDLINE via PubMed, TOXNET, and Scopus databases (from inception to 20 April 2015) using the key word "Asthma" together with "swimming pool", "disinfection by-products", "indoor air pollution" and "children". Inclusion criteria were: English language, a complete analytic study design involving a cohort of children (0-16 years), a well-defined definition of exposure, and the presence of data on effect and variance. Studies on in vivo, in vitro or professional and accidental exposure were excluded. After a screening process, seven reports (n = 5851 subjects) were included out of a total of 2928 references. The reported OR of the association between swimming pool attendance and asthma prevalence ranged from 0.58 to 2.30. The present meta-analysis failed to identify a significant difference in asthma development between children attending swimming pools and controls (OR, 1.084; 95% CI: 0.89-1.31). Swimming in childhood does not increase the likelihood of doctor-diagnosed asthma. Based on this meta-analysis review, the association of the disease with indoor pool attendance is still unclear. © 2016 Japan Pediatric Society.

  10. Health risks of early swimming pool attendance.

    PubMed

    Schoefer, Yvonne; Zutavern, Anne; Brockow, Inken; Schäfer, Torsten; Krämer, Ursula; Schaaf, Beate; Herbarth, Olf; von Berg, Andrea; Wichmann, H-Erich; Heinrich, Joachim

    2008-07-01

    Swimming pool attendance and exposure to chlorination by-products showed adverse health effects on children. We assessed whether early swimming pool attendance, especially baby swimming, is related to higher rates of early infections and to the development of allergic diseases. In 2003-2005, 2192 children were analysed for the 6-year follow-up of a prospective birth cohort study. Data on early swimming pool attendance, other lifestyle factors and medical history were collected by parental-administered questionnaire. Bivariate and multivariate logistic regression analyses were used to evaluate associations. Babies who did not participate in baby swimming had lower rates of infection in the 1st year of life (i) diarrhoea: OR 0.68 CI 95% 0.54-0.85; (ii) otitis media: OR 0.81 CI 95% 0.62-1.05; (iii) airway infections: OR 0.85 CI 95% 0.67-1.09. No clear association could be found between late or non-swimmers and atopic dermatitis or hay fever until the age of 6 years, while higher rates of asthma were found (OR 2.15 95% CI 1.16-3.99), however, potentially due to reverse causation. The study indicates that, in terms of infections, baby swimming might not be as harmless as commonly thought. Further evidence is needed to make conclusions if the current regulations on chlorine in Germany might not protect swimming pool attendees from an increased risk of gastrointestinal infections. In terms of developing atopic diseases there is no verifiable detrimental effect of early swimming.

  11. Perceived health problems in swimmers according to the chemical treatment of water in swimming pools.

    PubMed

    Fernández-Luna, Álvaro; Burillo, Pablo; Felipe, José Luis; del Corral, Julio; García-Unanue, Jorge; Gallardo, Leonor

    2016-01-01

    The objective of this study was to determine which chemical treatment used for disinfecting water in indoor swimming pools had the least impact on users' perceptions of health problems, and which generated the greatest satisfaction with the quality of the water. A survey on satisfaction and perceived health problems was given to 1001 users at 20 indoor swimming pools which used different water treatment methods [chlorine, bromine, ozone, ultraviolet lamps (UV) and salt electrolysis]. The findings suggest that there is a greater probability of perceived health problems, such as eye and skin irritation, respiratory problems and skin dryness, in swimming pools treated with chlorine than in swimming pools using other chemical treatment methods. Pools treated with bromine have similar, although slightly better, results. Other factors, such as age, gender, time of day of use (morning and afternoon) and type of user (competitive and recreational), can also affect the probability of suffering health problems. For all of the above, using combined treatment methods as ozone and UV, or salt electrolysis produces a lower probability of perceived health problems and greater satisfaction.

  12. What’s in the Pool? A Comprehensive Identification of Disinfection By-Products and Assessment of Mutagenicity of Chlorinated and Brominated Swimming Pool Water

    EPA Science Inventory

    Swimming pool disinfectants and disinfection by-products (DBPs) have been linked to human health effects, including asthma and bladder cancer, but no studies have provided a comprehensive identification of DBPs in pool water and related those DBPs to the mutagenicity of pool wate...

  13. Degradation Products of Benzophenone-3 in Chlorinated Seawater Swimming Pools.

    PubMed

    Manasfi, Tarek; Storck, Veronika; Ravier, Sylvain; Demelas, Carine; Coulomb, Bruno; Boudenne, Jean-Luc

    2015-08-04

    Oxybenzone (2-hydroxy-4-methoxyphenone, benzophenone-3) is one of the UV filters commonly found in sunscreens. Its presence in swimming pools and its reactivity with chlorine has already been demonstrated but never in seawater swimming pools. In these pools, chlorine added for disinfection results in the formation of bromine, due to the high levels of bromide in seawater, and leads to the formation of brominated disinfection byproducts, known to be more toxic than chlorinated ones. Therefore, it seems important to determine the transformation products of oxybenzone in chlorinated seawater swimming pools; especially that users of seawater swimming pools may apply sunscreens and other personal-care products containing oxybenzone before going to pools. This leads to the introduction of oxybenzone to pools, where it reacts with bromine. For this purpose, the reactivity of oxybenzone has been examined as a function of chlorine dose and temperature in artificial seawater to assess its potential to produce trihalomethanes and to determine the byproducts generated following chlorination. Increasing doses of chlorine and increasing temperatures enhanced the formation of bromoform. Experiments carried out with excess doses of chlorine resulted in the degradation of oxybenzone and allowed the determination of the degradation mechanisms leading to the formation of bromoform. In total, ten transformation products were identified, based on which the transformation pathway was proposed.

  14. Spatial analysis of paediatric swimming pool submersions by housing type.

    PubMed

    Shenoi, Rohit P; Levine, Ned; Jones, Jennifer L; Frost, Mary H; Koerner, Christine E; Fraser, John J

    2015-08-01

    Drowning is a major cause of unintentional childhood death. The relationship between childhood swimming pool submersions, neighbourhood sociodemographics, housing type and swimming pool location was examined in Harris County, Texas. Childhood pool submersion incidents were examined for spatial clustering using the Nearest Neighbor Hierarchical Cluster (Nnh) algorithm. To relate submersions to predictive factors, an Markov Chain Monte Carlo (MCMC) Poisson-Lognormal-Conditional Autoregressive (CAR) spatial regression model was tested at the census tract level. There were 260 submersions; 49 were fatal. Forty-two per cent occurred at single-family residences and 36% at multifamily residential buildings. The risk of a submersion was 2.7 times higher for a child at a multifamily than a single-family residence and 28 times more likely in a multifamily swimming pool than a single family pool. However, multifamily submersions were clustered because of the concentration of such buildings with pools. Spatial clustering did not occur in single-family residences. At the tract level, submersions in single-family and multifamily residences were best predicted by the number of pools by housing type and the number of children aged 0-17 by housing type. Paediatric swimming pool submersions in multifamily buildings are spatially clustered. The likelihood of submersions is higher for children who live in multifamily buildings with pools than those who live in single-family homes with pools. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  15. Swimming Pool Electrical Injuries: Steps Toward Prevention.

    PubMed

    Tashiro, Jun; Burnweit, Cathy A

    2017-01-09

    Electrical injuries in swimming pools are an important pediatric public health concern. We sought to (1) improve our understanding of the clinical presentation and outcomes following and (2) describe the epidemiology of swimming pool electrical injuries in the United States. We reviewed 4 cases of pediatric (<18 y old) electrical injury from a single, urban level 1 pediatric trauma center. We also queried the National Electronic Injury Surveillance System (NEISS) for emergency department visits due to electrical injury associated with swimming pools, occurring between 1991 and 2013. Overall, 566 cases were reported, with a mean (SD) age of 9.2 (4.1) years. Patients were mostly treated and released from the emergency department (91.8%), whereas 8.2% were hospitalized. When stated, injuries occurred most frequently at home (57.0%), followed by public (23.9%) and sports facilities (19.1%). Electrical outlets or receptacles (39.8%) were most commonly implicated, followed by electrical system doors (18.2%), electric wiring systems (17.0%), thermostats (16.3%), hair dryers (4.6%), and radios (4.1%). Pediatric cases represented 48.4% of swimming pool-related electrical injuries reported to NEISS. Electrical injuries occurring in and around swimming pools remain an important source of morbidity and mortality. Although NEISS monitors sentinel events, current efforts at preventing such cases are less than adequate. All electrical outlets near swimming pools should be properly wired with ground fault circuit interrupter devices. Possible approaches to increasing safe electrical device installation are through strengthening public awareness and education of the potential for injury, as well as changes to current inspection regulations.

  16. Health Effects from Swimming Training in Chlorinated Pools and the Corresponding Metabolic Stress Pathways

    PubMed Central

    Li, Jiang-Hua; Wang, Zhi-Hui; Zhu, Xiao-Juan; Deng, Zhao-Hui; Cai, Can-Xin; Qiu, Li-Qiang; Chen, Wei; Lin, Ya-Jun

    2015-01-01

    Chlorination is the most popular method for disinfecting swimming pool water; however, although pathogens are being killed, many toxic compounds, called disinfection by-products (DBPs), are formed. Numerous epidemiological publications have associated the chlorination of pools with dysfunctions of the respiratory system and with some other diseases. However, the findings concerning these associations are not always consistent and have not been confirmed by toxicological studies. Therefore, the health effects from swimming in chlorinated pools and the corresponding stress reactions in organisms are unclear. In this study, we show that although the growth and behaviors of experimental rats were not affected, their health, training effects and metabolic profiles were significantly affected by a 12-week swimming training program in chlorinated water identical to that of public pools. Interestingly, the eyes and skin are the organs that are more directly affected than the lungs by the irritants in chlorinated water; instead of chlorination, training intensity, training frequency and choking on water may be the primary factors for lung damage induced by swimming. Among the five major organs (the heart, liver, spleen, lungs and kidneys), the liver is the most likely target of DBPs. Through metabolomics analysis, the corresponding metabolic stress pathways and a defensive system focusing on taurine were presented, based on which the corresponding countermeasures can be developed for swimming athletes and for others who spend a lot of time in chlorinated swimming pools. PMID:25742134

  17. Drowning in Disinfection Byproducts? Swimming Pool Water Quality

    EPA Science Inventory

    Disinfection is mandatory for swimming pools, because transmission of disease by bacteria, virus and protozoa is the most significant health issue. However another issue arises, and care should be taken to minimize the risks from disinfection by-products (DBPs). Public pools are ...

  18. What’s in the Pool? A Comprehensive Identification of Disinfection By-products and Assessment of Mutagenicity of Chlorinated and Brominated Swimming Pool Water

    PubMed Central

    Richardson, Susan D.; DeMarini, David M.; Kogevinas, Manolis; Fernandez, Pilar; Marco, Esther; Lourencetti, Carolina; Ballesté, Clara; Heederik, Dick; Meliefste, Kees; McKague, A. Bruce; Marcos, Ricard; Font-Ribera, Laia; Grimalt, Joan O.; Villanueva, Cristina M.

    2010-01-01

    Background Swimming pool disinfectants and disinfection by-products (DBPs) have been linked to human health effects, including asthma and bladder cancer, but no studies have provided a comprehensive identification of DBPs in the water and related that to mutagenicity. Objectives We performed a comprehensive identification of DBPs and disinfectant species in waters from public swimming pools in Barcelona, Catalonia, Spain, that disinfect with either chlorine or bromine and we determined the mutagenicity of the waters to compare with the analytical results. Methods We used gas chromatography/mass spectrometry (GC/MS) to measure trihalomethanes in water, GC with electron capture detection for air, low- and high-resolution GC/MS to comprehensively identify DBPs, photometry to measure disinfectant species (free chlorine, monochloroamine, dichloramine, and trichloramine) in the waters, and an ion chromatography method to measure trichloramine in air. We assessed mutagenicity with the Salmonella mutagenicity assay. Results We identified > 100 DBPs, including many nitrogen-containing DBPs that were likely formed from nitrogen-containing precursors from human inputs, such as urine, sweat, and skin cells. Many DBPs were new and have not been reported previously in either swimming pool or drinking waters. Bromoform levels were greater in brominated than in chlorinated pool waters, but we also identified many brominated DBPs in the chlorinated waters. The pool waters were mutagenic at levels similar to that of drinking water (~ 1,200 revertants/L-equivalents in strain TA100–S9 mix). Conclusions This study identified many new DBPs not identified previously in swimming pool or drinking water and found that swimming pool waters are as mutagenic as typical drinking waters. PMID:20833605

  19. Occurrence and formation of disinfection by-products in the swimming pool environment: A critical review.

    PubMed

    Carter, Rhys A A; Joll, Cynthia A

    2017-08-01

    Disinfection of water for human use is essential to protect against microbial disease; however, disinfection also leads to formation of disinfection by-products (DBPs), some of which are of health concern. From a chemical perspective, swimming pools are a complex matrix, with continual addition of a wide range of natural and anthropogenic chemicals via filling waters, disinfectant addition, pharmaceuticals and personal care products and human body excretions. Natural organic matter, trace amounts of DBPs and chlorine or chloramines may be introduced by the filling water, which is commonly disinfected distributed drinking water. Chlorine and/or bromine is continually introduced via the addition of chemical disinfectants to the pool. Human body excretions (sweat, urine and saliva) and pharmaceuticals and personal care products (sunscreens, cosmetics, hair products and lotions) are introduced by swimmers. High addition of disinfectant leads to a high formation of DBPs from reaction of some of the chemicals with the disinfectant. Swimming pool air is also of concern as volatile DBPs partition into the air above the pool. The presence of bromine leads to the formation of a wide range of bromo- and bromo/chloro-DBPs, and Br-DBPs are more toxic than their chlorinated analogues. This is particularly important for seawater-filled pools or pools using a bromine-based disinfectant. This review summarises chemical contaminants and DBPs in swimming pool waters, as well as in the air above pools. Factors that have been found to affect DBP formation in pools are discussed. The impact of the swimming pool environment on human health is reviewed. Copyright © 2017. Published by Elsevier B.V.

  20. The Chemistry of Swimming Pool Maintenance

    ERIC Educational Resources Information Center

    Salter, Carl; Langhus, David L.

    2007-01-01

    The study of chemistry involved in the maintenance of a swimming pool provides a lot of chemical education to the students, including the demonstration of the importance of pH in water chemistry. The various chemical aspects hidden in the maintenance of the pool are being described.

  1. Electromagnetic Interference in a Private Swimming Pool: Case report.

    PubMed

    Iskandar, Sandia; Lavu, Madhav; Atoui, Moustapha; Lakkireddy, Dhanunjaya

    2015-01-01

    Although current lead design and filtering capabilities have greatly improved, Electromagnetic Interference (EMI) from environmental sources has been increasingly reported in patients with Cardiac Implantable Electronic Device (CIED) [1]. Few cases of inappropriate intracardiac Cardioverter Defibrillator (ICD) associated with swimming pool has been described [2]. Here we present a case of 64 year old male who presented with an interesting EMI signal that was subsequently identified to be related to AC current leak in his swimming pool.

  2. Experimental Measurements of the Water Evaporation Rate of a Physical Model

    NASA Astrophysics Data System (ADS)

    Turza, Róbert; Füri, Belo B.

    2017-03-01

    As the number of indoor swimming pools and wellness centers are currently growing, it is necessary to concentrate on the parameters of indoor environments. These parameters are necessary for the design of the HVAC systems that operate these premises. In indoor swimming-pool facilities, the energy demand is large due to ventilation losses from exhaust air. Since water evaporates from a pool's surface, exhaust air has a high water content and specific enthalpy. In this paper the results of the water evaporation rate measured from swimming pool surfaces at higher thermal water temperatures are described.

  3. Ingestion of swimming pool water by recreational swimmers.

    PubMed

    Dufour, A P; Behymer, T D; Cantú, R; Magnuson, M; Wymer, L J

    2017-06-01

    The volume of water ingested by swimmers while swimming is of great interest to individuals who develop risk assessments using quantitative microbial risk assessment or epidemiological approaches. We have used chloroisocyanurate disinfected swimming pool waters to determine the amount of water swallowed by swimmers during swimming activity. The chloroisocyanurate, which is in equilibrium with chlorine and cyanuric acid in the pool water, provides a biomarker, cyanuric acid, that once swallowed passes through the body into the urine unchanged. The concentration of cyanuric acid in a 24 hour urine specimen and the concentration in pool water can be used to calculate the amount of water swallowed. Our study population of 549 participants, which was about evenly divided by gender, and young and adult swimmers, indicated that swimmers ingest about 32 mL per hour (arithmetic mean) and that children swallowed about four times as much water as adults during swimming activities. It was also observed that males had a tendency to swallow more water than females during swimming activity and that children spent about twice as much time in the water than adults.

  4. Parasitic Diseases: Glossary

    MedlinePlus

    ... from swimming pools, hot tubs, Jacuzzis, spas, fountains, lakes, rivers, springs, ponds, streams, or the ocean. Recreational ... contact with contaminated water from swimming pools, spas, lakes, rivers, or the ocean. Back To Top (https:// ...

  5. Algicidal and Sanitizing Properties of Armazide1

    PubMed Central

    Antonides, H. J.; Tanner, W. S.

    1961-01-01

    Algicidal and sanitizing properties of Armazide, a new swimming pool additive, consisting of 12% w/v each of dodecylamine hydrochloride, trimethyl alkyl ammonium chloride, and methyl alkyl dipolyoxypropylene ammonium methyl sulfate in solution, were evaluated by laboratory techniques against algae and sewage. Results indicated it to be highly effective in low concentrations especially in conjunction with low concentrations of chlorine. Swimming pool field tests were found to confirm the laboratory findings. Various treatment levels and methods are described for swimming pools using treatments based upon the actual condition of the pool and water. The use of the product permitted a reduction in chlorine residual in pools resulting in greatly reduced requirements for chlorinating chemicals along with absence of irritation, odor, and other undesirable results usually associated with standard pool chlorination methods. PMID:13861802

  6. Giardia Infection (Giardiasis)

    MedlinePlus

    ... backcountry streams and lakes but also in municipal water supplies, swimming pools, whirlpool spas and wells. Giardia infection ... and streams worldwide, as well as in municipal water supplies, wells, cisterns, swimming pools, water parks and spas. ...

  7. Assessment of Physicochemical and Microbiological Quality of Public Swimming Pools in Addis Ababa, Ethiopia

    PubMed Central

    Yedeme, Kokebe; Legese, Melese Hailu; Gonfa, Almaz; Girma, Somson

    2017-01-01

    Background: From swimming pools, bathers may acquire many potential pathogens or may be affected by the physicochemical characteristics of water used during bathing. Hence, this study aimed at assessing the physicochemical and microbiological quality of public swimming pools located at different hotels and recreation center in Addis Ababa, Ethiopia. Method: A cross sectional study was carried out from February to May, 2016. Nine hotels and one recreation center which recognized to have public swimming services were included. A total of 60 swimming pool water samples from 10 swimming pools were collected at deeper, shallow and intake point twice on a weekly basis using a 250 ml sterile bottle containing sodium thiosulphate. PH, residual chlorine and temperature of samples were recorded at the time of collection. Sample containing bottles were transported in ice box to microbiological laboratory and analyzed on the same day. Standard cultural and biochemical methods were used for isolation and characterization of the main microbial groups. Total viable count, total coliform count, fecal coliform count and E. coli were determined. Data was analyzed using SPSS Version 20. Results: Average PH and temperature of swimming pool water samples were 7.1 and 29oC respectively. Of all analyzed water samples, 58.4% (n=35/60) of them had PH range of 7.2-7.8, 58.3% (n=35/60) of samples had temperature in the range of 21oC-32oC and 25% (n=15/60) of water samples had residual chlorine in the range of 2-3mg/l. 73.3% (n=44/60) of the samples had a total viable count below 200 MPN/ml and 70% (n-42/60) of the samples had Total Coliform Count values less than 2 MPN/100 ml. Moreover, 66.7% (n=40/60) of the samples had fecal coliform counts falling below 1 MPN /100 ml. E. coli was absent in 70% (n=42/60) of the samples while it was present in 30% (n=18/60) of the samples. Conclusion: PH, residual chlorine and temperature value of majority of the swimming pools’ water samples were within the acceptable limit. Regarding microbial quality, most swimming pools’ water samples complied to the WHO standard. Swimming pools that did not comply to the standard both in physicochemical levels and microbial quality need improvement due to their significant health implication. PMID:28761562

  8. 16 CFR 1207.2 - Effective date.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... STANDARD FOR SWIMMING POOL SLIDES § 1207.2 Effective date. This part 1207 shall become effective July 17, 1976. All swimming pool slides manufactured after that date must meet the requirements of this part...

  9. Swimming Pool Safety

    MedlinePlus

    ... Spread the Word Shop AAP Find a Pediatrician Safety & Prevention Immunizations All Around At Home At Play ... Español Text Size Email Print Share Swimming Pool Safety Page Content ​What is the best way to ...

  10. Seasonal dynamics of water and air chemistry in an indoor chlorinated swimming pool.

    PubMed

    Zare Afifi, Mehrnaz; Blatchley, Ernest R

    2015-01-01

    Although swimming is known to be beneficial in terms of cardiovascular health, as well as for some forms of rehabilitation, swimming is also known to present risks to human health, largely in the form of exposure to microbial pathogens and disinfection byproducts (DBPs). Relatively little information is available in the literature to characterize the seasonal dynamics of air and water chemistry in indoor chlorinated swimming pools. To address this issue, water samples were collected five days per week from an indoor chlorinated swimming pool facility at a high school during the academic year and once per week during summer over a fourteen-month period. The samples were analyzed for free and combined chlorine, urea, volatile DBPs, pH, temperature and total alkalinity. Membrane Introduction Mass Spectrometry (MIMS) was used to identify and measure the concentrations of eleven aqueous-phase volatile DBPs. Variability in the concentrations of these DBPs was observed. Factors that influenced variability included bather loading and mixing by swimmers. These compounds have the ability to adversely affect water and air quality and human health. A large fraction of the existing literature regarding swimming pool air quality has focused on trichloramine (NCl₃). For this work, gas-phase NCl₃ was analyzed by an air sparging-DPD/KI method. The results showed that gas-phase NCl₃ concentration is influenced by bather loading and liquid-phase NCl₃ concentration. Urea is the dominant organic-N compound in human urine and sweat, and is known to be an important precursor for producing NCl₃ in swimming pools. Results of daily measurements of urea indicated a link between bather load and urea concentration in the pool.

  11. HPLC DETERMINATION OF CYANURIC ACID IN SWIMMING POOL WATERS USING PHENYL AND CONFIRMATORY POROUS GRAPHITIC CARBON COLUMNS

    EPA Science Inventory

    The chlorinated salts of cyanuric acid have found an important role in recreational swimming pool waters across the United States. Upon application to pool water, they can (1) release disinfectant chlorine or (2) stabilize the free available chlorine by acting as chlorine reserv...

  12. Quantitative Measurement of Bromoform in Swimming Pool Water Using SPME with GC-MS. An Undergraduate Instrumental Analysis Experiment

    NASA Astrophysics Data System (ADS)

    Hardee, John R.; Long, John; Otts, Julie

    2002-05-01

    A senior-level undergraduate laboratory experiment that demonstrates the use of solid-phase microextraction (SPME) and capillary gas chromatography-mass spectrometry (GC-MS) was developed for the quantitative determination of bromoform in swimming pool water. Bromoform was extracted by SPME from the headspace of vials containing sodium chloride-saturated swimming pool water. Bromoform concentrations were determined from comparisons of peak areas on a student-generated calibration curve. Students compared results to OSHA water and air exposure limits for bromoform.

  13. Water safety training as a potential means of reducing risk of young children's drowning.

    PubMed Central

    Asher, K. N.; Rivara, F. P.; Felix, D.; Vance, L.; Dunne, R.

    1995-01-01

    OBJECTIVES: To determine the effects of training in swimming and water safety on young preschool-children's ability to recover safely from a simulated episode of falling into a swimming pool. DESIGN: Randomized trial of 12 or eight weeks' duration water safety and swimming lessons for children 24 to 42 months old. OUTCOME MEASURES: Swimming ability, deck behavior, water recovery, and swimming to side after jumping into pool were measured before, during, and after the training program. RESULTS: 109 children completed the study (61 in the 12 week group, 48 in the eight week group). The average age was 34.2 months, 54% were male. Swimming ability, deck behavior, water recovery, and jump and swim skills improved over baseline levels in both groups. By the end of training, the 12 week group improved more than the eight week group only in swimming ability. Improvements in water recovery and jump and swim skills were associated positively with changes in swimming ability. CONCLUSIONS: Swimming ability and safety skills of young preschool children can be improved through training. Such programs may offer some protection for children at risk of drowning and there was no indication that this program increased the risk of drowning. However, pool fencing, other barriers around water, and parental supervision still remain the most important prevention strategies to reduce drowning in young children. PMID:9346036

  14. Effects of exposure to water disinfection by-products in a swimming pool: A metabolome-wide association study.

    PubMed

    van Veldhoven, Karin; Keski-Rahkonen, Pekka; Barupal, Dinesh K; Villanueva, Cristina M; Font-Ribera, Laia; Scalbert, Augustin; Bodinier, Barbara; Grimalt, Joan O; Zwiener, Christian; Vlaanderen, Jelle; Portengen, Lützen; Vermeulen, Roel; Vineis, Paolo; Chadeau-Hyam, Marc; Kogevinas, Manolis

    2018-02-01

    Exposure to disinfection by-products (DBPs) in drinking water and chlorinated swimming pools are associated with adverse health outcomes, but biological mechanisms remain poorly understood. Evaluate short-term changes in metabolic profiles in response to DBP exposure while swimming in a chlorinated pool. The PISCINA-II study (EXPOsOMICS project) includes 60 volunteers swimming 40min in an indoor pool. Levels of most common DBPs were measured in water and in exhaled breath before and after swimming. Blood samples, collected before and 2h after swimming, were used for metabolic profiling by liquid-chromatography coupled to high-resolution mass-spectrometry. Metabolome-wide association between DBP exposures and each metabolic feature was evaluated using multivariate normal (MVN) models. Sensitivity analyses and compound annotation were conducted. Exposure levels of all DBPs in exhaled breath were higher after the experiment. A total of 6,471 metabolic features were detected and 293 features were associated with at least one DBP in exhaled breath following Bonferroni correction. A total of 333 metabolic features were associated to at least one DBP measured in water or urine. Uptake of DBPs and physical activity were strongly correlated and mutual adjustment reduced the number of statistically significant associations. From the 293 features, 20 could be identified corresponding to 13 metabolites including compounds in the tryptophan metabolism pathway. Our study identified numerous molecular changes following a swim in a chlorinated pool. While we could not explicitly evaluate which experiment-related factors induced these associations, molecular characterization highlighted metabolic features associated with exposure changes during swimming. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  15. Investigation of Air Quality Problems in an Indoor Swimming Pool: A Case Study.

    PubMed

    Lévesque, Benoit; Vézina, Lorraine; Gauvin, Denis; Leroux, Patrice

    2015-10-01

    Trichloramine (NCl3) is the contaminant suspected the most to cause irritative respiratory symptoms among swimmers and swimming pool workers. Following complaints by employees working in an indoor swimming pool, this study set out to identify the determinants of NCl3 air concentrations in that particular swimming pool. To document NCl3 air levels, air samples (n = 26) were collected once or twice a day for 3 h, at least 3 days per week, between October and December 2011. Water samples were taken three times during air sampling to verify free chlorine, chloramines, alkalinity, conductivity, pH, water temperature, and turbidity. Water changes were also recorded, along with the number of bathers. Ventilation (outdoor air flow) was modified to verify the influence of this important variable. Data were evaluated by analysis of variance. Mean NCl3 air concentration was 0.38 mg m(-3). The best model explaining variations of NCl3 air levels (r2 = 0.83) included sampling period (P = 0.002, NCl3 was higher in the evening versus the morning), water changes (P = 0.02, NCl3 was lower with water changes between 60 and 90 min day(-1) versus <60 min day(-1)), and ventilation (P = 0.0002, NCl3 was lower with ≥2 air changes per hour (ACH) versus <1 ACH). Although based on only 26 air samples, our results indicate that ventilation is an important determinant of NCl3 air concentration in swimming pool air. There is limited information available on the air quality of indoor swimming pools and the relationship with ventilation. Efforts are needed to document the situation and to develop state-of-the-art facilities for ventilation of indoor swimming pools. © The Author 2015. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.

  16. Can you really swim? Validation of self and parental reports of swim skill with an inwater swim test among children attending community pools in Washington State.

    PubMed

    Mercado, Melissa C; Quan, Linda; Bennett, Elizabeth; Gilchrist, Julie; Levy, Benjamin A; Robinson, Candice L; Wendorf, Kristen; Gangan Fife, Maria Aurora; Stevens, Mark R; Lee, Robin

    2016-08-01

    Drowning is the second leading cause of unintentional injury death among US children. Multiple studies describe decreased drowning risk among children possessing some swim skills. Current surveillance for this protective factor is self/proxy-reported swim skill rather than observed inwater performance; however, children's self-report or parents' proxy report of swim skill has not been validated. This is the first US study to evaluate whether children or parents can validly report a child's swim skill. It also explores which swim skill survey measure(s) correlate with children's inwater swim performance. For this cross-sectional convenience-based sample, pilot study, child/parent dyads (N=482) were recruited at three outdoor public pools in Washington State. Agreement between measures of self-reports and parental-reports of children's swim skill was assessed via paired analyses, and validated by inwater swim test results. Participants were representative of pool's patrons (ie, non-Hispanic White, highly educated, high income). There was agreement in child/parent dyads' reports of the following child swim skill measures: 'ever taken swim lessons', perceived 'good swim skills' and 'comfort in water over head'. Correlation analyses suggest that reported 'good swim skills' was the best survey measure to assess a child's swim skill-best if the parent was the informant (r=0.25-0.47). History of swim lessons was not significantly correlated with passing the swim test. Reported 'good swim skills' was most correlated with observed swim skill. Reporting 'yes' to 'ever taken swim lessons' did not correlate with swim skill. While non-generalisable, findings can help inform future studies. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  17. What's in The Pool? A Comprehensive Identification Of Disinfection By-Products and Assessment of Mutagenicity of Chlorinated and Brominated Swimming Pool Water

    EPA Science Inventory

    Swimming pool disinfectants and disinfection by-products (DBPs) have been linked to human health effects, including asthma and bladder cancer, but no studies have provided a comprehensive identification of DBPs in the water and related that to mutagenicity. We performed a compreh...

  18. WATER INGESTION DURING SWIMMING ACTIVITIES IN A POOL: A PILOT STUDY

    EPA Science Inventory

    Chloroisocyanurates are commonly added to outdoor swimming pools to stabilize chlorine disinfectants. The chloroisocyanurates decompose slowly to release chlorine and cyanuric acid. Studies conducted to determine if the chloroisocyanurates might be toxic to swimmers showed that...

  19. Current Warm-Up Practices and Contemporary Issues Faced by Elite Swimming Coaches.

    PubMed

    McGowan, Courtney J; Pyne, David B; Raglin, John S; Thompson, Kevin G; Rattray, Ben

    2016-12-01

    McGowan, CJ, Pyne, DB, Raglin, JS, Thompson, KG, and Rattray, B. Current warm-up practices and contemporary issues faced by elite swimming coaches. J Strength Cond Res 30(12): 3471-3480, 2016-A better understanding of current swimming warm-up strategies is needed to improve their effectiveness. The purpose of this study was to describe current precompetition warm-up practices and identify contemporary issues faced by elite swimming coaches during competition. Forty-six state-international level swimming coaches provided information through a questionnaire on their prescription of volume, intensity, and recovery within their pool and dryland-based competition warm-ups, and challenges faced during the final stages of event preparation. Coaches identified four key objectives of the precompetition warm-up: physiological (elevate body temperature and increase muscle activation), kinesthetic (tactile preparation, increase "feel" of the water), tactical (race-pace rehearsal), and mental (improve focus, reduce anxiety). Pool warm-up volume ranged from ∼1300 to 2100 m, beginning with 400-1000 m of continuous, low-intensity (∼50-70% of perceived maximal exertion) swimming, followed by 200-600 m of stroke drills and 1-2 sets (100-400 m in length) of increasing intensity (∼60-90%) swimming, concluding with 3-4 race or near race-pace efforts (25-100 m; ∼90-100%) and 100-400 m easy swimming. Dryland-based warm-up exercises, involving stretch cords and skipping, were also commonly prescribed. Coaches preferred swimmers complete their warm-up 20-30 minutes before race start. Lengthy marshalling periods (15-20+ minutes) and the time required to don racing suits (>10 minutes) were identified as complicating issues. Coaches believed that the pool warm-up affords athletes the opportunity to gain a tactile feel for the water and surrounding pool environment. The combination of dryland-based activation exercises followed by pool-based warm-up routines seems to be the preferred approach taken by elite swimming coaches preparing their athletes for competition.

  20. [Pseudomonas folliculitis outbreaks associated with swimming pools or whirlpools in two guest-room sites in the northern region of Israel].

    PubMed

    Cohen-Dar, Michal; DiCastro, Noa; Grotto, Itamar

    2012-07-01

    In summer 2010-2011 two outbreaks of Pseudomonas foliculitis occurred among bathers who used the swimming pools or whirlpools in two guest-room sites. The source of the infection was traced to the swimming pools or whirlpools, which had not been chlorinated and monitored routinely. Of 40 bathers, 25 (62.5%) developed Pseudomonas folliculitis 2-4 days after exposure. Typically the rash began as a pruritic erythematous papule on the buttocks, axilla, and extremities, with fever, adenopathy and otitis externa. In the culture of the pustules and bacterial examination grew Pseudomonas aeroginosa. Pseudomonas folliculitis was first described by McCausland and Cox in 1975. To the best of our knowledge, this is the first description of outbreaks in swimming pools or whirlpools in guest-room sites in Israel. This article describes the epidemiological and environmental health investigation of the two outbreaks. With the rising popularity of swimming pools and whirlpools in guest-room sites, physicians in the community and the emergency rooms may encounter this disease. We urge their real time report to the public health offices, in charge of the epidemiological inquires, aiming to prevent the occurrence of new cases or improper treatment of similar cases.

  1. Rapid general dental erosion by gas-chlorinated swimming pool water. Review of the literature and case report.

    PubMed

    Geurtsen, W

    2000-12-01

    Several reports indicate an increased prevalence of dental erosion among intensive swimmers due to low pH gas-chlorinated pool water. Contrary to other extrinsic factors which induce erosion located on the facial aspect, low pH pool water results in general dental erosion. Additionally, a case report is presented which describes the very rapid occurrence of excessive general dental erosion of a competitive swimmer due to gas-chlorinated pool water within 27 days. The observation of several authors as well as this case underscore the significance of a regular pH monitoring of chlorinated swimming pool water. The high incidence indicates that dental erosion due to frequent swimming is of considerable diagnostic and therapeutic significance. Furthermore, it is recommended to fluoridate the teeth of intensive swimmers regularly to prevent dental erosion.

  2. Modeling evaporation from spent nuclear fuel storage pools: A diffusion approach

    NASA Astrophysics Data System (ADS)

    Hugo, Bruce Robert

    Accurate prediction of evaporative losses from light water reactor nuclear power plant (NPP) spent fuel storage pools (SFPs) is important for activities ranging from sizing of water makeup systems during NPP design to predicting the time available to supply emergency makeup water following severe accidents. Existing correlations for predicting evaporation from water surfaces are only optimized for conditions typical of swimming pools. This new approach modeling evaporation as a diffusion process has yielded an evaporation rate model that provided a better fit of published high temperature evaporation data and measurements from two SFPs than other published evaporation correlations. Insights from treating evaporation as a diffusion process include correcting for the effects of air flow and solutes on evaporation rate. An accurate modeling of the effects of air flow on evaporation rate is required to explain the observed temperature data from the Fukushima Daiichi Unit 4 SFP during the 2011 loss of cooling event; the diffusion model of evaporation provides a significantly better fit to this data than existing evaporation models.

  3. A swimming pool array for ultra high energy showers

    NASA Astrophysics Data System (ADS)

    Yodh, Gaurang B.; Shoup, Anthony; Barwick, Steve; Goodman, Jordan A.

    1992-11-01

    A very preliminary design concept for an array using water Cherenkov counters, built out of commercially available backyard swimming pools, to sample the electromagnetic and muonic components of ultra high energy showers at large lateral distances is presented. The expected performance of the pools is estimated using the observed lateral distributions by scintillator and water Cherenkov arrays at energies above 1019 eV and simulations.

  4. AN INFERENTIAL INDEX OF SWIMMING POOL PURITY

    PubMed Central

    Fair, Gordon M.

    1920-01-01

    Score cards for swimming pools is the suggestion of this paper. Figures about these establishments are today in the class with crude statistics, and may lead to unreliable conclusions. Here are suggested various indexes which may be of service in framing minimum requirements for these pools. This article is an effort to clear up a complicated matter for which there are not now accepted standards. PMID:18010324

  5. IDENTIFICATION OF DISINFECTION BY-PRODUCTS IN SWIMMING POOL WATER

    EPA Science Inventory

    In order to kill harmful pathogens, swimming pool water is treated with a disinfectant, such as chlorine or ozone. One of the most commonly used disinfectants is stabilized chlorine (typically trichloro-S-triazinetrione). Trichloro-S-triazinetrione reacts in water to form one m...

  6. Swimming Pools, Hot Rods, and Qualitative Analysis.

    ERIC Educational Resources Information Center

    Clyde, Dale D.

    1988-01-01

    Describes some reactions for the identification and application of cyanuric acid. Suggests students may find this applied chemistry interesting because of the use of cyanuric acid in swimming pools and diesel engines. Lists three tests for cyanate ion and two tests for cyanuric acid. (MVL)

  7. Development of the laboratory prototype "CavyPool" for assessing treatments and materials for swimming pools.

    PubMed

    Valeriani, F; Gianfranceschi, G; Vitali, M; Protano, C; Romano Spica, V

    2017-01-01

    Hygiene and surveillance in swimming pools are established by WHO Guidelines and national laws. Progress in water management and pool construction is revolutionizing the field, introducing new materials, systems, disinfection procedures or monitoring markers. Innovation advances challenge the upgrading of safety and quality in pools and the appropriate implementation of guidelines. In order to provide a device for laboratory test, a prototype was realized and applied to study and compare swimming pool materials and treatments. A pool scale-model was engineered and evaluated by computational fluid dynamics algorithms. An automated real time monitoring assured steady state. Critical control points along the water circuit were made accessible to allow the placing of different biocides or water sampling. Simulations were safely performed in a standard hood. Materials for pool surfaces and pipelines were evaluated for biofilm formation under different disinfection conditions. Adherent microorganisms were assayed by mfDNA analysis using real time PCR. The prototype reached the steady state within 5-25 hours under different conditions, showing chemical, physical and fluid-dynamic stability. A method was optimized for testing materials showing their different response to biofilm induction. Several innovative PVC samples displayed highest resistance to bacterial adhesion. A device and method was developed for testing swimming pool hygienic parameters in laboratory. It allowed to test materials for pools hygiene and maintenance, including biofilm formation. It can be applied to simulate contaminations under different water treatments or disinfection strategies. It may support technical decisions and help policymakers in acquiring evidences for comparing or validating innovative solutions.

  8. Nebraska DHHS: Swimming Pool Program

    Science.gov Websites

    Skip to main content Official Nebraska Government Website NE-DHHS Home Header Behavioral Health Children and Family Services Developmental Disabilities Medicaid and Long Term Care Public Health DHHS Internet Website - Public Health DHHS Internet Website - Public Health : Nebraska DHHS: Swimming Pool

  9. Nitrates, chlorates and trihalomethanes in swimming pool water.

    PubMed Central

    Beech, J A; Diaz, R; Ordaz, C; Palomeque, B

    1980-01-01

    Water from swimming pools in the Miami area was analyzed for nitrates, chlorates and trihalomethanes. The average concentrations of nitrate and chlorate found in freshwater pools were 8.6 mg/liter and 16 mg/liter respectively, with the highest concentrations being 54.9 mg/liter and 124 mg/liter, respectively. The average concentration of total trihalomethanes found in freshwater pools was 125 micrograms/liter (mainly chloroform) and in saline pools was 657 micrograms/liter (mainly bromoform); the highest concentration was 430 micrograms/liter (freshwater) and 1287 micrograms/liter (saltwater). The possible public health significance of these results is briefly discussed. PMID:7350831

  10. Childhood Asthma and Environmental Exposures at Swimming Pools: State of the Science and Research Recommendations

    EPA Science Inventory

    Recent studies have explored the potential for swimming pool disinfection byproducts (DBPs) which are respiratory irritants to cause asthma in young children. While these studies raise concerns, gaps still exist in our knowledge regarding the exact causal agents and mechanisms f...

  11. Changes in Markers of Genotoxicity in Relation to Exposure to Disinfection By-Products in Swimming Pools

    EPA Science Inventory

    Exposure to disinfection by-products (DBPs) has been associated with cancer risk, but the mechanisms of action are poorly understood. A recent study found increased bladder cancer risk among subjects attending swimming pools, where uptake of DBPs, such as trihalomethanes (THMs) c...

  12. Illicit drugs and pharmaceuticals in swimming pool waters.

    PubMed

    Fantuzzi, G; Aggazzotti, G; Righi, E; Predieri, G; Castiglioni, S; Riva, F; Zuccato, E

    2018-09-01

    The occurrence of illicit drugs (cocaine, opioids, amphetamines and cannabis derivatives), some of their metabolites and 48 pharmaceuticals, was investigated in pool and source waters in ten Italian indoor swimming pools. The samples were analyzed by highperformance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS), after solid phase extraction (SPE). Cocaine and its metabolites were found in nine swimming pools, at concentrations from 0.3 to 4.2 ng/L for cocaine, 1.1 to 48.7 ng/L for norcocaine, 0.7 to 21.4 ng/L for benzoylecgonine and 0.1 to 7.3 ng/L for norbenzoylecgonine. Opioids, amphetamines and cannabis derivatives were never detected. The most frequent pharmaceuticals were anti-inflammatory drugs: ibuprofen was found in all the pool waters, with a maximum 197 ng/L and ketoprofen was detected in 9/10 samples (maximum 127 ng/L). Among anticonvulsants, carbamazepine and its metabolite, 10,11-dihydro-10,11dihydroxycarbamazepine, were frequent in swimming pool water (8/10 samples) at concentrations up to 62 ng/L. The cardiovascular drug valsartan was also found frequently (8/10 samples), but at lower concentrations (up to 9 ng/L). Other pharmaceuticals were detected occasionally and at lower concentrations (atenolol, enalapril, paracetamol, hydroclorothiazide, irbesartan and dehydro-erythromycin). Carbamazepine, irbesartan and dehydroerythromycin were detected at very low levels (up to 5 ng/L) in only one of the four source water samples. A quantitative risk assessment showed that the health risk for humans to these substance in swimming pool waters was generally negligible, even for vulnerable subpopulations such as children and adolescents. Copyright © 2018 Elsevier B.V. All rights reserved.

  13. Lip and tooth injuries at public swimming pools in Austria.

    PubMed

    Lechner, Katharina; Connert, Thomas; Kühl, Sebastian; Filippi, Andreas

    2017-06-01

    There is an increased risk of orofacial injuries in swimming pool facilities. Nevertheless, only a few studies have addressed this issue. The aim of this study was to identify the frequency of lip and tooth injuries at public swimming pools in Austria. A further aim was to examine which gender and age groups were affected, where and why these injuries occurred, and whether pool attendants had sufficient knowledge of dental first-aid measures. A total of 764 pool attendants in Austria were contacted by telephone and 689 participated in the study (90.2%). The attendants were interviewed retrospectively about accident occurrences in 2014 by a standardized questionnaire. Responses to the provision of first aid and choice of storage medium for avulsed teeth were subsequently evaluated. The frequency of lip injuries was 19.0%, and tooth injuries were 11.3%. Male bathers (P < .05) and children under 12 years (P < .001) most frequently suffered injuries. The waterslide was the most common accident site. The most common cause of lip injuries was slipping on wet surfaces (39.0%), and for tooth injuries it was collisions with other persons or objects (each 28.1%). The pool attendants' responses were predominantly good or sufficient on first aid, with the exception of what storage medium to choose. Tooth rescue boxes were available in only 8.6% of all pool facilities. Orofacial injuries are a frequently occurring problem in swimming pool facilities. The pool attendants' knowledge on first-aid care of tooth injuries could still be improved. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  14. Partial nitritation of raw anaerobic sludge digester liquor by swim-bed and swim-bed activated sludge processes and comparison of their sludge characteristics.

    PubMed

    Qiao, Sen; Kawakubo, Yuki; Koyama, Toichiro; Furukawa, Kenji

    2008-11-01

    This study evaluated performance of swim-bed (SB) reactors packed with a novel acrylic fiber carrier (BF) and swim-bed activated sludge (SBAS) reactor for partial nitritation of anaerobic sludge digester liquor from a municipal wastewater treatment plant. Comparison of characteristics of sludge obtained from both the reactors was also made. The average conversion rates of ammonium to nitrite were 52.3% and 40.0% under relatively high nitrogen loading rates over 3.0 kg-N/m(3)/d, respectively in two reactors. The average BOD(5) removal efficiencies were 74.3% and 64.4%, respectively in the two reactors. The size of the sludge pellets taken from SB and SBAS reactors was found to be approximately three times (229 mum versus 88 mum) of that of the seed sludge. This sludge also had relatively high extracellular proteins levels indicating better sludge settling capability as compared to the sludge taken from SBAS reactor. Although the effluent nitrite/ammonium ratios had fluctuated in both reactor in some extent, the low dissolved oxygen concentration (average of 2.5 versus 0.35 mg/l), low suspended solids (average of 33.3 versus 33.5 mg/l), and about 50% ammonium conversion to nitrite demonstrated the application potential of anammox process for nitrogen removal.

  15. Improving Pool Fencing Legislation in Queensland, Australia: Attitudes and Impact on Child Drowning Fatalities

    PubMed Central

    2017-01-01

    Four-sided, non-climbable pool fencing is an effective strategy for preventing children from drowning in home swimming pools. In 2009, the Queensland Government introduced legislation to improve the effectiveness of pool fencing. This study explores community attitudes towards the effectiveness of these legislative changes and examines child (<5 years) drowning deaths in pools. Data from the 2011 Queensland Computer-Assisted Telephone Interviewing (CATI) Social Survey include results from questions related to pool ownership and pool fencing legislation. Fatal child drowning cases between 1 January 2005 and 31 December 2015 were sourced from coronial data. Of the 1263 respondents, 26/100 households had a pool. A total of 58% believed tightening legislation would be effective in reducing child drowning deaths. Pool owners were more likely to doubt the effectiveness of legislation (p < 0.001) when compared to non-pool owners. Perceptions of effectiveness did not differ by presence of children under the age of five. There were 46 children who drowned in Queensland home pools (7.8/100,000 pools with children residing in the residence/annum) between 2005 and 2015. While pool owners were less likely to think that tightening the legislation would be effective, the number of children drowning in home swimming pools declined over the study period. Drowning prevention agencies have more work to do to ensure that the most vulnerable (young children in houses with swimming pools) are protected. PMID:29186787

  16. 26 CFR 1.263A-10 - Unit of property.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... road and clears the land for one house. Under the principles of paragraph (b)(1) of this section, each... project consisting of a condominium building and a common swimming pool that is not held for the..., and each story is occupied by a single condominium. Production of the swimming pool begins in January...

  17. 26 CFR 1.263A-10 - Unit of property.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... road and clears the land for one house. Under the principles of paragraph (b)(1) of this section, each... project consisting of a condominium building and a common swimming pool that is not held for the..., and each story is occupied by a single condominium. Production of the swimming pool begins in January...

  18. 26 CFR 1.263A-10 - Unit of property.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... road and clears the land for one house. Under the principles of paragraph (b)(1) of this section, each... project consisting of a condominium building and a common swimming pool that is not held for the..., and each story is occupied by a single condominium. Production of the swimming pool begins in January...

  19. 26 CFR 1.263A-10 - Unit of property.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... road and clears the land for one house. Under the principles of paragraph (b)(1) of this section, each... project consisting of a condominium building and a common swimming pool that is not held for the..., and each story is occupied by a single condominium. Production of the swimming pool begins in January...

  20. Swimming Pool Water Treatment Chemicals and/or Processes. Standard No. 22.

    ERIC Educational Resources Information Center

    National Sanitation Foundation, Ann Arbor, MI.

    Chemicals or processes used or intended for use, in the treatment of swimming pool water are covered. Minimum public health limits or acceptability in regard to toxicity, biocidal effectiveness, and chemical behavior and analysis are presented. The appendices give guidelines to the scientific and statistically sound evaluations to determine the…

  1. Outbreak of Pseudomonas aeruginosa folliculitis associated with a swimming pool inflatable.

    PubMed Central

    Tate, D.; Mawer, S.; Newton, A.

    2003-01-01

    On 18 February 2002, the Communicable Disease Unit was notified by the local Public Health Service Laboratory of a child with a positive skin swab for Pseudomonas aeruginosa. This child had attended the local swimming pool and played on an inflatable, subsequently presenting to a Primary Care Nurse Practitioner with folliculitis. A total of 35 cases was identified during the outbreak. This paper describes a case-control study and microbiological sampling of the cases, the suspected inflatable and a survey of 10 swimming pool inflatables in the local area. The odds ratio for developing folliculitis following use of the inflatable was 12 (95% CI 1.05-136.80). The strain of P. aeruginosa found on the inflatable was identical to that obtained from skin swabs of cases. Nine of 10 (90%) of the inflatables sampled were colonized by P. aeruginosa. Attention should be given to the problem of routine decontamination of swimming pool inflatables. P. aeruginosa folliculitis needs to be considered in the differential diagnosis of skin rashes in children, especially in Primary Care. PMID:12729186

  2. Gene expression changes in blood RNA after swimming in a chlorinated pool.

    PubMed

    Salas, Lucas A; Font-Ribera, Laia; Bustamante, Mariona; Sumoy, Lauro; Grimalt, Joan O; Bonnin, Sarah; Aguilar, Maria; Mattlin, Heidi; Hummel, Manuela; Ferrer, Anna; Kogevinas, Manolis; Villanueva, Cristina M

    2017-08-01

    Exposure to disinfection by-products (DBP) such as trihalomethanes (THM) in swimming pools has been linked to adverse health effects in humans, but their biological mechanisms are unclear. We evaluated short-term changes in blood gene expression of adult recreational swimmers after swimming in a chlorinated pool. Volunteers swam 40min in an indoor chlorinated pool. Blood samples were drawn and four THM (chloroform, bromodichloromethane, dibromochloromethane and bromoform) were measured in exhaled breath before and after swimming. Intensity of physical activity was measured as metabolic equivalents (METs). Gene expression in whole blood mRNA was evaluated using IlluminaHumanHT-12v3 Expression-BeadChip. Linear mixed models were used to evaluate the relationship between gene expression changes and THM exposure. Thirty-seven before-after pairs were analyzed. The median increase from baseline to after swimming were: 0.7 to 2.3 for MET, and 1.4 to 7.1μg/m 3 for exhaled total THM (sum of the four THM). Exhaled THM increased on average 0.94μg/m 3 per 1 MET. While 1643 probes were differentially expressed post-exposure. Of them, 189 were also associated with exhaled levels of individual/total THM or MET after False Discovery Rate. The observed associations with the exhaled THM were low to moderate (Log-fold change range: -0.17 to 0.15). In conclusion, we identified short-term gene expression changes associated with swimming in a pool that were minor in magnitude and their biological meaning was unspecific. The high collinearity between exhaled THM levels and intensity of physical activity precluded mutually adjusted models with both covariates. These exploratory results should be validated in future studies. Copyright © 2017. Published by Elsevier B.V.

  3. Enhancing swimming pool safety by the use of range-imaging cameras

    NASA Astrophysics Data System (ADS)

    Geerardyn, D.; Boulanger, S.; Kuijk, M.

    2015-05-01

    Drowning is the cause of death of 372.000 people, each year worldwide, according to the report of November 2014 of the World Health Organization.1 Currently, most swimming pools only use lifeguards to detect drowning people. In some modern swimming pools, camera-based detection systems are nowadays being integrated. However, these systems have to be mounted underwater, mostly as a replacement of the underwater lighting. In contrast, we are interested in range imaging cameras mounted on the ceiling of the swimming pool, allowing to distinguish swimmers at the surface from drowning people underwater, while keeping the large field-of-view and minimizing occlusions. However, we have to take into account that the water surface of a swimming pool is not a flat, but mostly rippled surface, and that the water is transparent for visible light, but less transparent for infrared or ultraviolet light. We investigated the use of different types of 3D cameras to detect objects underwater at different depths and with different amplitudes of surface perturbations. Specifically, we performed measurements with a commercial Time-of-Flight camera, a commercial structured-light depth camera and our own Time-of-Flight system. Our own system uses pulsed Time-of-Flight and emits light of 785 nm. The measured distances between the camera and the object are influenced through the perturbations on the water surface. Due to the timing of our Time-of-Flight camera, our system is theoretically able to minimize the influence of the reflections of a partially-reflecting surface. The combination of a post image-acquisition filter compensating for the perturbations and the use of a light source with shorter wavelengths to enlarge the depth range can improve the current commercial cameras. As a result, we can conclude that low-cost range imagers can increase swimming pool safety, by inserting a post-processing filter and the use of another light source.

  4. Swimming in a contained space: Understanding the experience of indoor lap swimmers.

    PubMed

    Ward, Miranda

    2017-07-01

    Drawing on ethnographic work, this paper explores the convergence of bodies, materialities and practices found at the indoor swimming pool - a space that has not often been the subject of geographical study, in spite of the fact that swimming is one of the most popular forms of exercise in countries such as the UK. The paper focuses on the "contained" nature of the indoor pool environment, examining the distinct experience this can create for lap swimmers. This focus is placed in the context of a broader politics of exercise, with an emphasis on the popularity and potential benefits of swimming, as well as less encouraging facts about participation and facility provision, suggesting that in order to encourage further uptake of swimming and preservation of swimming facilities the voices and experiences of regular swimmers should be considered. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. Credit USAF, ca. 1943. Original housed in the Muroc Flight ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Credit USAF, ca. 1943. Original housed in the Muroc Flight Test Base, Unit History, 1 September 1942 - 30 June 1945. Alfred F. Simpson Historical Research Agency. United States Air Force. Maxwell AFB, Alabama. Historic view looking north across southwest end of swimming pool as army personnel work on finishing the pool bottom. View looks towards Mess Hall (T-10) on Second Street - Edwards Air Force Base, North Base, Swimming Pool, Second Street, Boron, Kern County, CA

  6. Dynamic real-time monitoring of chloroform in an indoor swimming pool air using open-path Fourier transform infrared spectroscopy.

    PubMed

    Chen, M-J; Duh, J-M; Shie, R-H; Weng, J-H; Hsu, H-T

    2016-06-01

    This study used open-path Fourier transform infrared (OP-FTIR) spectroscopy to continuously assess the variation in chloroform concentrations in the air of an indoor swimming pool. Variables affecting the concentrations of chloroform in air were also monitored. The results showed that chloroform concentrations in air varied significantly during the time of operation of the swimming pool and that there were two peaks in chloroform concentration during the time of operation of the pool. The highest concentration was at 17:30, which is coincident with the time with the highest number of swimmers in the pool in a day. The swimmer load was one of the most important factors influencing the chloroform concentration in the air. When the number of swimmers surpassed 40, the concentrations of chloroform were on average 4.4 times higher than the concentration measured without swimmers in the pool. According to the results of this study, we suggest that those who swim regularly should avoid times with highest number of swimmers, in order to decrease the risk of exposure to high concentrations of chloroform. It is also recommended that an automatic mechanical ventilation system is installed to increase the ventilation rate during times of high swimmer load. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  7. [Surveillance of the sanitary conditions of a public swimming pool in the city of Palermo (Italy)].

    PubMed

    Maida, Carmelo Massimo; Di Benedetto, Maria Antonella; Firenze, Alberto; Calamusa, Giuseppe; Di Piazza, Florinda; Milici, Maria Eleonora; Romano, Nino

    2008-01-01

    In a previous study we evaluated the microbiological quality of water of seven pools in the city of Palermo through evaluation of bacterial indicators of faecal contamination and of protozoa (Giardia and Cryptosporidium). In this study we also searched for the presence of fungi in two swimming pools of a public swimming facility in the same city. Samples were collected from both pools, their filtration systems and floor surfaces of the facility. Chemical-physical and microbiological examination of water of the two pools have shown that quality of water depends on the concentration of residual free chlorine and on the number of bathers in the pool. The values of four microbiological parameters (bacterial load at 22 degrees C and 36 degrees C, presence of coagulase-negative Staphylococci and Pseudomonas spp.) increased with diminishing chlorine concentrations and with increasing number of pool users. Faecal bacteria, Giardia and Cryptosporidium were not found. On the other hand, various fungi were isolated from floor surfaces and pool water even in the presence of optimal chlorine concentrations. This study confirms the importance of regular maintenance of pool disinfection systems and suggests the need to search for other micro-organisms not included in the current legislation (Giardia, Cryptosporidium and fungi).

  8. Associations between testicular hormones at adolescence and attendance at chlorinated swimming pools during childhood

    PubMed Central

    Nickmilder, M; Bernard, A

    2011-01-01

    The goal was to evaluate the associations between testicular hormones at adolescence and the exposure to chlorination by-products when attending chlorinated swimming pools. We obtained serum samples from 361 school male adolescents (aged 14–18 years) who had visited swimming pools disinfected with chlorine or by copper–silver ionization. We analysed serum concentrations of inhibin B (two different assays), total and free testosterone, sex hormone-binding globulin, luteinizing hormone (LH), follicle stimulating hormone (FSH) and dehydroepiandrosterone sulphate (DHEAS). There were strong inverse associations between serum levels of inhibin B (both assays) or of total testosterone, adjusted or unadjusted for gonadotropins and the time adolescents had spent in indoor chlorinated pools, especially during their childhood. Adolescents having attended indoor chlorinated pools for more than 250 h before the age of 10 years or for more than 125 h before the age of 7 years were about three times more likely to have an abnormally low serum inhibin B and/or total testosterone (<10th percentile) than their peers who never visited this type of pool during their childhood (odds ratio, 95% CI, 2.83, 1.06–7.52, p = 0.04 and 3.67, 1.45–9.34, p = 0.006, respectively). Such associations were not seen with free testosterone, LH, FSH and DHEAS or with the attendance of outdoor chlorinated pools or of the copper–silver pool. Swimming in indoor chlorinated pools during childhood is strongly associated with lower levels of serum inhibin B and total testosterone. The absorption of reprotoxic chlorination by-products across the highly permeable scrotum might explain these associations. PMID:21631527

  9. Predicting performance in competitive apnea diving, part II: dynamic apnoea.

    PubMed

    Schagatay, Erika

    2010-03-01

    Part I of this series of articles identified the main physiological factors defining the limits of static apnea, while this paper reviews the factors involved when physical work is added in the dynamic distance disciplines, performed in shallow water in a swimming pool. Little scientific work has been done concerning the prerequisites and limitations of swimming with or without fins whilst breath holding to extreme limits. Apneic duration influences all competitive apnea disciplines, and can be prolonged by any means that increase gas storage or tolerance to asphyxia, or reduce metabolic rate, as reviewed in the first article. For horizontal underwater distance swimming, the main challenge is to restrict metabolism despite the work, and to direct blood flow only to areas where demand is greatest, to allow sustained function. Here, work economy, local tissue energy and oxygen stores and the anaerobic capacity of the muscles are key components. Improvements in swimming techniques and, especially in swimming with fins, equipment have already contributed to enhanced performance and may do so further. High lactate levels observed after competition swims suggest a high anaerobic component, and muscle hypoxia could ultimately limit muscle work and swimming distance. However, the frequency of syncope, especially in swimming without fins, suggests that cerebral oxygenation may often be compromised before this occurs. In these pool disciplines, safety is high and the dive can be interrupted by the competitor or safety diver within seconds. The safety routines in place during pool competitions are described.

  10. Swimming pool exposure is associated with autonomic changes and increased airway reactivity to a beta-2 agonist in school aged children: A cross-sectional survey.

    PubMed

    Cavaleiro Rufo, João; Paciência, Inês; Silva, Diana; Martins, Carla; Madureira, Joana; Oliveira Fernandes, Eduardo de; Padrão, Patrícia; Moreira, Pedro; Delgado, Luís; Moreira, André

    2018-01-01

    Endurance swimming exercises coupled to disinfection by-products exposure has been associated with increased airways dysfunction and neurogenic inflammation in elite swimmers. However, the impact of swimming pool exposure at a recreational level on autonomic activity has never been explored. Therefore, this study aimed to investigate how swimming pool attendance is influencing lung and autonomic function in school-aged children. A total of 858 children enrolled a cross sectional survey. Spirometry and airway reversibility to beta-2 agonist, skin-prick-tests and exhaled nitric oxide measurements were performed. Pupillometry was used to evaluate autonomic nervous function. Children were classified as current swimmers (CS), past swimmers (PS) and non-swimmers (NS), according to the amount of swimming practice. Current swimmers group had significantly lower maximum and average pupil constriction velocities when compared to both PS and NS groups (3.8 and 5.1 vs 3.9 and 5.3 vs 4.0 and 5.4 mm/s, p = 0.03 and p = 0.01, respectively). Moreover, affinity to the beta-2 agonist and levels of exhaled nitric oxide were significantly higher in CS when compared to NS (70 vs 60 mL and 12 vs 10 ppb, p<0.01 and p = 0.03, respectively). A non-significant trend for a higher risk of asthma, atopic eczema and allergic rhinitis was found with more years of swimming practice, particularly in atopic individuals (β = 1.12, 1.40 and 1.31, respectively). After case-case analysis, it was possible to observe that results were not influenced by the inclusion of individuals with asthma. Concluding, swimming pool attendance appears to be associated with autonomic changes and increased baseline airway smooth muscle constriction even in children without asthma.

  11. From Source Water to Tap Water to Spa and Swimming Pool Water: Effects of Disinfectanta and Precursors and Implications for Exposure and Toxicity

    EPA Science Inventory

    Introduction The current study investigated the effect of different disinfection treatments on the disinfection by-products (DBPs) formed in finished drinking water vs. tap water vs. swimming pool water vs. spa waters. To this end, samples across the complete water pathway (untr...

  12. The Pool Is Not Just for Swimming

    ERIC Educational Resources Information Center

    Metzker, Andrea

    2004-01-01

    Participating in water fitness workouts is one way to benefit one's health at very little cost. If the pool at a school is used only for swimming, then the benefits of having one barely causes a ripple. When the properties of water and how humans react to water are understood and applied to water activity programs, health benefits and enjoyment…

  13. Diatomite Type Filters for Swimming Pools. Standard No. 9, Revised October, 1966.

    ERIC Educational Resources Information Center

    National Sanitation Foundation, Ann Arbor, MI.

    Pressure and vacuum diatomite type filters are covered in this standard. The filters herein described are intended to be designed and used specifically for swimming pool water filtration, both public and residential. Included are the basic components which are a necessary part of the diatomite type filter such as filter housing, element supports,…

  14. Sand Type Filters for Swimming Pools. Standard No. 10, Revised October, 1966.

    ERIC Educational Resources Information Center

    National Sanitation Foundation, Ann Arbor, MI.

    Sand type filters are covered in this standard. The filters described are intended to be designed and used specifically for swimming pool water filtration, both public and residential. Included are the basic components which are a necessary part of the sand type filter such as filter housing, upper and lower distribution systems filter media,…

  15. Health Benefits of Water-based Exercise

    MedlinePlus

    ... the Pool Raccoons & Pools Birds & Pools Aquatics Professionals Design & Construction Designing Public Swimming Facilities Historic CDC Design & Operation Manuals Operation & Maintenance 12 Steps for Prevention ...

  16. Kick, Stroke and Swim: Complement Your Swimming Program by Engaging the Whole Body on Dry Land and in the Pool

    ERIC Educational Resources Information Center

    Flynn, Susan; Duell, Kelly; Dehaven, Carole; Heidorn, Brent

    2017-01-01

    The Kick, Stroke and Swim (KSS) program can be used to engage students in swimming-skill acquisition and fitness training using a variety of modalities, strategies and techniques on dry land. Practicing swim strokes and techniques on land gives all levels of swimmers--from beginner to competitive--a kinesthetic awareness of the individual…

  17. Design of hydrotherapy exercise pools.

    PubMed

    Edlich, R F; Abidin, M R; Becker, D G; Pavlovich, L J; Dang, M T

    1988-01-01

    Several hydrotherapy pools have been designed specifically for a variety of aquatic exercise. Aqua-Ark positions the exerciser in the center of the pool for deep-water exercise. Aqua-Trex is a shallow underwater treadmill system for water walking or jogging. Swim-Ex generates an adjustable laminar flow that permits swimming without turning. Musculoskeletal conditioning can be accomplished in the above-ground Arjo shallow-water exercise pool. A hydrotherapy pool also can be custom designed for musculoskeletal conditioning in its shallow part and cardiovascular conditioning in a deeper portion of the pool. Regardless of the type of exercise, there is general agreement that the specific exercise conducted in water requires significantly more energy expenditure than when the same exercise is performed on land.

  18. All-automatic swimmer tracking system based on an optimized scaled composite JTC technique

    NASA Astrophysics Data System (ADS)

    Benarab, D.; Napoléon, T.; Alfalou, A.; Verney, A.; Hellard, P.

    2016-04-01

    In this paper, an all-automatic optimized JTC based swimmer tracking system is proposed and evaluated on real video database outcome from national and international swimming competitions (French National Championship, Limoges 2015, FINA World Championships, Barcelona 2013 and Kazan 2015). First, we proposed to calibrate the swimming pool using the DLT algorithm (Direct Linear Transformation). DLT calculates the homography matrix given a sufficient set of correspondence points between pixels and metric coordinates: i.e. DLT takes into account the dimensions of the swimming pool and the type of the swim. Once the swimming pool is calibrated, we extract the lane. Then we apply a motion detection approach to detect globally the swimmer in this lane. Next, we apply our optimized Scaled Composite JTC which consists of creating an adapted input plane that contains the predicted region and the head reference image. This latter is generated using a composite filter of fin images chosen from the database. The dimension of this reference will be scaled according to the ratio between the head's dimension and the width of the swimming lane. Finally, applying the proposed approach improves the performances of our previous tracking method by adding a detection module in order to achieve an all-automatic swimmer tracking system.

  19. 13 CFR 120.1704 - Pool Loans eligible for Pooling.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ..., construction or renovation of an aquarium, zoo, golf course, or swimming pool; or (iv) To a business covered by... zoos—712130 (“Zoos and Botanical Gardens”). (b) SBA review of a Pool Loan prior to pool formation. SBA...

  20. 13 CFR 120.1704 - Pool Loans eligible for Pooling.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ..., construction or renovation of an aquarium, zoo, golf course, or swimming pool; or (iv) To a business covered by... zoos—712130 (“Zoos and Botanical Gardens”). (b) SBA review of a Pool Loan prior to pool formation. SBA...

  1. 13 CFR 120.1704 - Pool Loans eligible for Pooling.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ..., construction or renovation of an aquarium, zoo, golf course, or swimming pool; or (iv) To a business covered by... zoos—712130 (“Zoos and Botanical Gardens”). (b) SBA review of a Pool Loan prior to pool formation. SBA...

  2. 13 CFR 120.1704 - Pool Loans eligible for Pooling.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ..., construction or renovation of an aquarium, zoo, golf course, or swimming pool; or (iv) To a business covered by... zoos—712130 (“Zoos and Botanical Gardens”). (b) SBA review of a Pool Loan prior to pool formation. SBA...

  3. 13 CFR 120.1704 - Pool Loans eligible for Pooling.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ..., construction or renovation of an aquarium, zoo, golf course, or swimming pool; or (iv) To a business covered by... zoos—712130 (“Zoos and Botanical Gardens”). (b) SBA review of a Pool Loan prior to pool formation. SBA...

  4. Credit PSR. View looking north northeast (12°) across surface remains ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Credit PSR. View looking north northeast (12°) across surface remains of North Base swimming pool. The southeast edge of the pool appearing in the foreground may seem to be a sidewalk to the casual observer; the wavy inside edge of this walk matches the pool side visible in historic construction photos (See HAER photo CA-170-Q-2). The telephone pole in the midground of the view is inside the pool proper. Building 4312 (Liquid Oxygen Repair Facility) appears in left background, Building 4456 (Fire House No. 4) in middle background, and Building 4444 (Communications Building) in right background - Edwards Air Force Base, North Base, Swimming Pool, Second Street, Boron, Kern County, CA

  5. Case histories of building material problems caused by condensation at an enclosed swimming pool and an enclosed ice rink

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    VanGeem, M.G.; Farahmandpour, K.; Gajda, J.

    1999-07-01

    Enclosed swimming pools and ice rinks in winter climates have the potential for high indoor relative humidities and cold building materials. These elements can contribute to condensation and premature deterioration of building materials. Case histories are provided for an enclosed swimming pool and an enclosed ice rink with condensation problems. An evaluation was performed after roof leaks were reported at a recently constructed indoor swimming pool in a Chicago suburb. After a preliminary inspection, it was evident that the reported leaks were related to building moisture problems rather than a roof leak. Exterior brick masonry exhibited heavy efflorescence in themore » area of the swimming pools, and water streaks were visible on the exterior walls below the eaves. The evaluation included laboratory testing, a visual inspection, field tests and measurements, and analyses for condensation potential. Results of the evaluation indicated the presence of condensed moisture as a direct cause of the observed water stains, and masonry efflorescence. Recommended corrective actions developed. A 54-year-old enclosed ice rink in New England was under investigation to determine the cause of a deteriorated wood deck roof. The building did not have dehumidification or air handling systems, and was heated only when occupied. The evaluation included visual inspection and analyses for condensation potential. Results of the evaluation indicated condensation within the wood decking and insulation during winter months, and high relative humidities that prohibited drying during the spring, summer, and fall. These conditions, over an extended number of years, resulted in decay of the wood decking.« less

  6. Korean Affairs Report

    DTIC Science & Technology

    1986-09-25

    will 22 be equipped with 2,000 seats, a swimming pool equipped with 2,100 seats, a pingpong gymnasium equipped with 3,000 seats, a badminton ...swimming, diving, water polo, and synchronized swimming can be held. The badminton gymnasium will be octagonal, a unique shape. This gymnasium, which

  7. Chlorine disinfection of recreational water for Cryptosporidium parvum.

    PubMed Central

    Carpenter, C.; Fayer, R.; Trout, J.; Beach, M. J.

    1999-01-01

    We examined the effects of chlorine on oocyst viability, under the conditions of controlled pH and elevated calcium concentrations required for most community swimming pools. We found that fecal material may alter the Ct values (chlorine concentration in mg/L, multiplied by time in minutes) needed to disinfect swimming pools or other recreational water for Cryptosporidium parvum. PMID:10458969

  8. Color Fringes Bordering Black Stripes at the Bottom of a Swimming Pool

    ERIC Educational Resources Information Center

    Fuster, Gonzalo; Rojas, Roberto; Slüsarenko, Viktor

    2016-01-01

    We have observed a nice example of chromatic dispersion due to refraction in water, in the form of color fringes bordering the black stripes that exist at the bottom of a swimming pool. Here we give a qualitative description of the phenomenon, explaining the role of the black stripes and the dispersive index of refraction of water.

  9. The Recreational Water Cycle: From Source Water to Tap Water to Spa and Swimming Pool Water: Effects of Disinfectants and Precursors and Implications for Exposure and Toxicity

    EPA Science Inventory

    The current study investigates the effect of different disinfection treatments on the disinfection by-products (DBPs) formed in finished drinking water vs. tap water vs. swimming pool water vs. spa waters. To this end, complete water pathway samples (untreated source waters ->fi...

  10. Occurrence of Cryptosporidium and Giardia and the Relationship between Protozoa and Water Quality Indicators in Swimming Pools.

    PubMed

    Xiao, Shumin; Yin, Pengna; Zhang, Yan; Hu, Sike

    2017-04-01

    A total of 60 samples were collected from 35 swimming pools in Beijing, China, and the presence of Cryptosporidium and Giardia were investigated. The results showed that 16.7% and 15.0% of samples were positive for Cryptosporidium oocyst and Giardia cysts, respectively, with a mean concentration of 0.30 oocysts/10 L and 0.27 cysts/10 L. The oocysts and cysts were found to have higher rates of occurrence in August than in May. Genotyping confirmed the presence of Cryptosporidium hominis, C. parvum , and Giardia assemblages A and B, all of which were associated with human infections. The predominant species/assemblages were C. hominis and Giardia assemblage A. Analyses of the relationships between parasite oocysts/cysts, indicator bacteria, and physical-chemical parameters revealed that there was no correlation between 2 parasites and fecal bacterial indicators, whilst there was a significant correlation between protozoa and urea concentration, which indicates that urea concentration rather than fecal bacterial indicators might be an appropriate index for chlorine-resistant protozoa in swimming pools. This study provides useful information to improve the safety of swimming pool water and deduce the risk of protozoan infections.

  11. [Hygienic risks in swimming pool: knowledge and behaviours of consumers of three structures in Crema, Parma and Naples].

    PubMed

    Liguori, G; Castaldi, S; Signorelli, C; Auxilia, F; Alfano, V; Saccani, E; Visciano, A; Fanti, M; Spinelli, A; Pasquarella, C

    2007-01-01

    The swimmers health's protection and the maintenance of good safety standards of structures can be guaranteed under observance of rules and the well management of the structures and activities. An anonymous questionnaire, with 38 items, was used in order to analyse and better understand the knowledge and behaviour of the users of three swimming pools in Crema, Naples and Parma. Socio-demographic features were similar in the three centres. One of the most important result was that the necessity of showers and foot-bath before entering the swimming pool is not well understood (77% and 78% respectively); caps and foot bath are, instead, almost always worn (98% and 97%). Knowledge on infection diseases transmitted by water is very poor, warts and mycosis being the best known. Sport structures are places where health and wellness can be affected. It is important to underline the role of behavioural rules as the use of showers, caps, and proper shoes. Authors recognize the swimming pool regulations as a valid tool for health promotion. It must be clear and easily understood and it has to be linked to a proper education pathway of all users and employees.

  12. Surveillance and Molecular Identification of Acanthamoeba and Naegleria Species in Two Swimming Pools in Alexandria University, Egypt

    PubMed Central

    AL-HERRAWY, Ahmad Z.; KHALIL, Mahmoud I.; EL-SHERIF, Soheir S.; OMAR, Fatima A. E.; LOTFY, Wael M.

    2017-01-01

    Background: Swimming in contaminated water was reported to be associated with Acanthamoeba and N. fowleri human infections. The present study was carried out with the aim of isolation and identification of the different species of Acanthamoeba and Naegleria from two swimming pools in Alexandria University. Methods: Samples were collected from the swimming pools of Alexandria University Stadium and Faculty of Agriculture-Alexandria University during the period from May 2012 to April 2013. Results: Free-living amoebae were prevalent in the collected samples. Molecular characterization confirmed the identity of ten Acanthamoeba isolates and seven Naegleria isolates. Acanthamoeba T3, T4, T5, T11 and T15 genotypes were identified. Acanthamoeba T4 was the most prevalent genotype. Conclusion: The relatively high prevalence of Acanthamoeba, especially genotype T4, indicates the presence of a health hazard to swimmers particularly those wearing contact lenses. Naegleria fowleri was not found during the present study. PMID:28761479

  13. Photolytic removal of DBPs by medium pressure UV in swimming pool water.

    PubMed

    Hansen, Kamilla M S; Zortea, Raissa; Piketty, Aurelia; Vega, Sergio Rodriguez; Andersen, Henrik Rasmus

    2013-01-15

    Medium pressure UV is used for controlling the concentration of combined chlorine (chloramines) in many public swimming pools. Little is known about the fate of other disinfection by-products (DBPs) in UV treatment. Photolysis by medium pressure UV treatment was investigated for 12 DBPs reported to be found in swimming pool water: chloroform, bromodichloromethane, dibromochloromethane, bromoform, dichloroacetonitrile, bromochloroacetonitrile, dibromoacetronitrile, trichloroacetonitrile, trichloronitromethane, dichloropropanone, trichloropropanone, and chloral hydrate. First order photolysis constants ranged 26-fold from 0.020 min(-1) for chloroform to 0.523 min(-1) for trichloronitromethane. The rate constants generally increased with bromine substitution. Using the UV removal of combined chlorine as an actinometer, the rate constants were recalculated to actual treatment doses of UV applied in a swimming pool. In an investigated public pool the UV dose was equivalent to an applied electrical energy of 1.34 kWh m(-3) d(-1) and the UV dose required to removed 90% of trichloronitromethane was 0.4 kWh m(-3) d(-1), while 2.6 kWh m(-3) d(-1) was required for chloral hydrate and the bromine containing haloacetonitriles and trihalomethanes ranged from 0.6 to 3.1 kWh m(-3) d(-1). It was predicted thus that a beneficial side-effect of applying UV for removing combined chlorine from the pool water could be a significant removal of trichloronitromethane, chloral hydrate and the bromine containing haloacetonitriles and trihalomethanes. Copyright © 2012 Elsevier B.V. All rights reserved.

  14. Prevalence of dental erosion in adolescent competitive swimmers exposed to gas-chlorinated swimming pool water.

    PubMed

    Buczkowska-Radlińska, J; Łagocka, R; Kaczmarek, W; Górski, M; Nowicka, A

    2013-03-01

    The purpose of this study was to analyze the prevalence of dental erosion among competitive swimmers of the local swimming club in Szczecin, Poland, who train in closely monitored gas-chlorinated swimming pool water. The population for this survey consisted of a group of junior competitive swimmers who had been training for an average of 7 years, a group of senior competitive swimmers who had been training for an average of 10 years, and a group of recreational swimmers. All subjects underwent a clinical dental examination and responded to a questionnaire regarding aspects of dental erosion. In pool water samples, the concentration of calcium, magnesium, phosphate, sodium, and potassium ions and pH were determined. The degree of hydroxyapatite saturation was also calculated. Dental erosion was found in more than 26 % of the competitive swimmers and 10 % of the recreational swimmers. The lesions in competitive swimmers were on both the labial and palatal surfaces of the anterior teeth, whereas erosions in recreational swimmers developed exclusively on the palatal surfaces. Although the pH of the pool water was neutral, it was undersaturated with respect to hydroxyapatite. The factors that increase the risk of dental erosion include the duration of swimming and the amount of training. An increased risk of erosion may be related to undersaturation of pool water with hydroxyapatite components. To decrease the risk of erosion in competitive swimmers, the degree of dental hydroxyapatite saturation should be a controlled parameter in pool water.

  15. The effect of core configuration on temperature coefficient of reactivity in IRR-1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bettan, M.; Silverman, I.; Shapira, M.

    1997-08-01

    Experiments designed to measure the effect of coolant moderator temperature on core reactivity in an HEU swimming pool type reactor were performed. The moderator temperature coefficient of reactivity ({alpha}{sub {omega}}) was obtained and found to be different in two core loadings. The measured {alpha}{sub {omega}} of one core loading was {minus}13 pcm/{degrees}C at the temperature range of 23-30{degrees}C. This value of {alpha}{sub {omega}} is comparable to the data published by the IAEA. The {alpha}{sub {omega}} measured in the second core loading was found to be {minus}8 pcm/{degrees}C at the same temperature range. Another phenomenon considered in this study is coremore » behavior during reactivity insertion transient. The results were compared to a core simulation using the Dynamic Simulator for Nuclear Power Plants. It was found that in the second core loading factors other than the moderator temperature influence the core reactivity more than expected. These effects proved to be extremely dependent on core configuration and may in certain core loadings render the reactor`s reactivity coefficient undesirable.« less

  16. The physiology and biomechanics of competitive swimming.

    PubMed

    Troup, J P

    1999-04-01

    Fast swimming, either in the pool, in open water swimming, or in water polo and synchronized swimming, requires maximizing the efficiencies with which the human body can move through a liquid medium. A multitude of factors can affect the ability to swim fast as well as the final outcome. Physiology and biomechanics are the present tools used by sports scientists to determine which factors are important to fast swimming and, subsequently, to determine how the swimmer may maximize these factors to improve performance.

  17. Credit USAF, ca. 1943. Original housed in the Muroc Flight ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Credit USAF, ca. 1943. Original housed in the Muroc Flight Test Base, Unit History, 1 September 1942 - 30 June 1945. Alfred F. Simpson Historical Research Agency. United States Air Force. Maxwell AFB, Alabama. Historic view looking northeast along southeast edge of swimming pool during construction. The wavy edge of the pool visible here remains as a ground surface feature in 1995. Building in the background is the second Bachelor Officers' Quarters (T-15) built in 1943 - Edwards Air Force Base, North Base, Swimming Pool, Second Street, Boron, Kern County, CA

  18. Centrifugal Pumps for Swimming Pools. National Sanitation Foundation Standard Number 17.

    ERIC Educational Resources Information Center

    National Sanitation Foundation, Ann Arbor, MI. Committee for Swimming Pool Equipment Standards.

    The pumps discussed herein are intended to be used for recirculating water in swimming pools, both public and private. Included are the basic components which may be a part of a pump such as the housing, strainer, impeller, valves, and such other parts as are attached or a part of the pump as supplied by the manufacturer. This standard is intended…

  19. Control of reactor coolant flow path during reactor decay heat removal

    DOEpatents

    Hunsbedt, Anstein N.

    1988-01-01

    An improved reactor vessel auxiliary cooling system for a sodium cooled nuclear reactor is disclosed. The sodium cooled nuclear reactor is of the type having a reactor vessel liner separating the reactor hot pool on the upstream side of an intermediate heat exchanger and the reactor cold pool on the downstream side of the intermediate heat exchanger. The improvement includes a flow path across the reactor vessel liner flow gap which dissipates core heat across the reactor vessel and containment vessel responsive to a casualty including the loss of normal heat removal paths and associated shutdown of the main coolant liquid sodium pumps. In normal operation, the reactor vessel cold pool is inlet to the suction side of coolant liquid sodium pumps, these pumps being of the electromagnetic variety. The pumps discharge through the core into the reactor hot pool and then through an intermediate heat exchanger where the heat generated in the reactor core is discharged. Upon outlet from the heat exchanger, the sodium is returned to the reactor cold pool. The improvement includes placing a jet pump across the reactor vessel liner flow gap, pumping a small flow of liquid sodium from the lower pressure cold pool into the hot pool. The jet pump has a small high pressure driving stream diverted from the high pressure side of the reactor pumps. During normal operation, the jet pumps supplement the normal reactor pressure differential from the lower pressure cold pool to the hot pool. Upon the occurrence of a casualty involving loss of coolant pump pressure, and immediate cooling circuit is established by the back flow of sodium through the jet pumps from the reactor vessel hot pool to the reactor vessel cold pool. The cooling circuit includes flow into the reactor vessel liner flow gap immediate the reactor vessel wall and containment vessel where optimum and immediate discharge of residual reactor heat occurs.

  20. Titanium distribution in swimming pool water is dominated by dissolved species.

    PubMed

    David Holbrook, R; Motabar, Donna; Quiñones, Oscar; Stanford, Benjamin; Vanderford, Brett; Moss, Donna

    2013-10-01

    The increased use of titanium dioxide nanoparticles (nano-TiO2) in consumer products such as sunscreen has raised concerns about their possible risk to human and environmental health. In this work, we report the occurrence, size fractionation and behavior of titanium (Ti) in a children's swimming pool. Size-fractionated samples were analyzed for Ti using ICP-MS. Total titanium concentrations ([Ti]) in the pool water ranged between 21 μg/L and 60 μg/L and increased throughout the 101-day sampling period while [Ti] in tap water remained relatively constant. The majority of [Ti] was found in the dissolved phase (<1 kDa), with only a minor fraction of total [Ti] being considered either particulate or microparticulate. Simple models suggest that evaporation may account for the observed variation in [Ti], while sunscreen may be a relevant source of particulate and microparticule Ti. Compared to diet, incidental ingestion of nano-Ti from swimming pool water is minimal. Published by Elsevier Ltd.

  1. Drowning

    MedlinePlus

    ... Preschoolers are most likely to drown in a swimming pool. People who have seizure disorders are also ... near any body of water, including tubs Not swimming or boating when under the influence of alcohol ...

  2. Short-term changes in respiratory biomarkers after swimming in a chlorinated pool.

    PubMed

    Font-Ribera, Laia; Kogevinas, Manolis; Zock, Jan-Paul; Gómez, Federico P; Barreiro, Esther; Nieuwenhuijsen, Mark J; Fernandez, Pilar; Lourencetti, Carolina; Pérez-Olabarría, Maitane; Bustamante, Mariona; Marcos, Ricard; Grimalt, Joan O; Villanueva, Cristina M

    2010-11-01

    Swimming in chlorinated pools involves exposure to disinfection by-products (DBPs) and has been associated with impaired respiratory health. We evaluated short-term changes in several respiratory biomarkers to explore mechanisms of potential lung damage related to swimming pool exposure. We measured lung function and biomarkers of airway inflammation [fractional exhaled nitric oxide (FeNO), eight cytokines, and vascular endothelial growth factor (VEGF) in exhaled breath condensate], oxidative stress (8-isoprostane in exhaled breath condensate), and lung permeability [surfactant protein D (SP-D) and the Clara cell secretory protein (CC16) in serum] in 48 healthy nonsmoking adults before and after they swam for 40 min in a chlorinated indoor swimming pool. We measured trihalomethanes in exhaled breath as a marker of individual exposure to DBPs. Energy expenditure during swimming, atopy, and CC16 genotype (rs3741240) were also determined. Median serum CC16 levels increased from 6.01 to 6.21 microg/L (average increase, 3.3%; paired Wilcoxon test p = 0.03), regardless of atopic status and CC16 genotype. This increase was explained both by energy expenditure and different markers of DBP exposure in multivariate models. FeNO was unchanged overall but tended to decrease among atopics. We found no significant changes in lung function, SP-D, 8-isoprostane, eight cytokines, or VEGF. We detected a slight increase in serum CC16, a marker of lung epithelium permeability, in healthy adults after they swam in an indoor chlorinated pool. Exercise and DBP exposure explained this association, without involving inflammatory mechanisms. Further research is needed to confirm the results, establish the clinical relevance of short-term serum CC16 changes, and evaluate the long-term health impacts.

  3. Swimming pool exposure is associated with autonomic changes and increased airway reactivity to a beta-2 agonist in school aged children: A cross-sectional survey

    PubMed Central

    Paciência, Inês; Silva, Diana; Martins, Carla; Madureira, Joana; de Oliveira Fernandes, Eduardo; Padrão, Patrícia; Moreira, Pedro; Delgado, Luís; Moreira, André

    2018-01-01

    Background Endurance swimming exercises coupled to disinfection by-products exposure has been associated with increased airways dysfunction and neurogenic inflammation in elite swimmers. However, the impact of swimming pool exposure at a recreational level on autonomic activity has never been explored. Therefore, this study aimed to investigate how swimming pool attendance is influencing lung and autonomic function in school-aged children. Methods A total of 858 children enrolled a cross sectional survey. Spirometry and airway reversibility to beta-2 agonist, skin-prick-tests and exhaled nitric oxide measurements were performed. Pupillometry was used to evaluate autonomic nervous function. Children were classified as current swimmers (CS), past swimmers (PS) and non-swimmers (NS), according to the amount of swimming practice. Results Current swimmers group had significantly lower maximum and average pupil constriction velocities when compared to both PS and NS groups (3.8 and 5.1 vs 3.9 and 5.3 vs 4.0 and 5.4 mm/s, p = 0.03 and p = 0.01, respectively). Moreover, affinity to the beta-2 agonist and levels of exhaled nitric oxide were significantly higher in CS when compared to NS (70 vs 60 mL and 12 vs 10 ppb, p<0.01 and p = 0.03, respectively). A non-significant trend for a higher risk of asthma, atopic eczema and allergic rhinitis was found with more years of swimming practice, particularly in atopic individuals (β = 1.12, 1.40 and 1.31, respectively). After case-case analysis, it was possible to observe that results were not influenced by the inclusion of individuals with asthma. Conclusions Concluding, swimming pool attendance appears to be associated with autonomic changes and increased baseline airway smooth muscle constriction even in children without asthma. PMID:29529048

  4. ASCANs Helms and Gregory swim in pool during Elgin AFB survival training

    NASA Image and Video Library

    1990-09-20

    1990 Group 13 Astronaut Candidates (ASCANs) Susan J. Helms (foreground) and William G. Gregory, wearing helmets and flight suits, swim in pool at Elgin Air Force Base (AFB) in Pensacola, Florida, during water survival exercises. The training familiarized the candidates with survival techniques necessary in the event of a water landing. ASCANs participated in the exercises from 08-14-90 through 08-17-90.

  5. 26 CFR 1.528-4 - Substantiality test.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... residence. Units which are used for purposes auxiliary to residential use (such as laundry areas, swimming... may be used for parking spaces, swimming pools, tennis courts, schools, fire stations, libraries...

  6. Occurrence of brominated disinfection byproducts in the air and water of chlorinated seawater swimming pools.

    PubMed

    Manasfi, Tarek; Temime-Roussel, Brice; Coulomb, Bruno; Vassalo, Laurent; Boudenne, Jean-Luc

    2017-05-01

    An undesirable consequence of disinfection is the formation of chemical contaminants known as disinfection byproducts (DBPs). Chronic exposure to DBPs has been linked to adverse health effects. The occurrence of DBPs in chlorinated pools filled with seawater (such as thalassotherapy pools and pools in spas) has received little attention so far. The present study evaluated the speciation and levels of disinfection byproducts in indoor swimming pools filled with seawater and treated with chlorine. Water and air samples were collected from three indoor swimming pools located in Southern France. Several classes of DBPs including trihalomethanes, haloacetic acids, haloacetonitriles, and trihaloacetaldehydes were analyzed in water. Halogenated volatile organic compounds were analyzed in air. Extractable organic halides (EOX) contents were determined using combustion/micro-coulometry system. The speciation of DBPs identified in the three pools was predominantly brominated. The mean (arithmetic) concentration of bromoform, dibromoacetic acid, tribromoacetic acid, dibromoacetonitrile and bromal hydrate in the three pools was 79.2, 72.9, 59.9, 26.9 and 10.0μg/L, respectively. By weight, HAAs represented the most abundant chemical class followed by THMs. In air, bromoform was the most abundant THM occurring at a mean concentration of 133.2μg/m 3 in the three pools. The mean EOX level was 706μgCl - /L for the three pools. In average, the quantified DBPs accounted for only 14% of EOX, thus 86% of EOX remained unknown. Further research is warranted to identify the unknown DBPs. Copyright © 2017 Elsevier GmbH. All rights reserved.

  7. Software for the Design of Swimming Pool Dehumidifiers Units

    NASA Astrophysics Data System (ADS)

    Rubina, Aleš; Blasinski, Petr; Tesař, Zdeněk

    2013-06-01

    The article deals with the description and solution of physical phenomena taking place during evaporation of water. The topicality of the theme is given a number of built indoor swimming pool and wellness centers at present. In addressing HVAC systems serving these areas, it is necessary to know the various design parameters in the interior including the water temperature as the pool temperature and humidity. Following is a description of the calculation module, air handling units, including optimizing the settings of the physical changes in order to ensure the lowest energy consumption for air treatment and required maintaining internal microclimate parameters.

  8. [Environmental surveillance of a sample of indoor swimming pools from Emilia Romagna region: microclimate characteristics and chemical parameters, particularly disinfection by products, in pool waters].

    PubMed

    Fantuzzi, G; Righi, E; Predieri, G; Giacobazzi, P; Mastroianni, K; Aggazzotti, G

    2010-01-01

    The aim of the present study was to investigate the environmental and healthy aspects from a representative sample of indoor swimming pools located in the Emilia Romagna region. During the sampling sessions, the occupational environment was evaluated in terms of microclimate parameters and thermal comfort/discomfort conditions. Moreover the chemical risk was assessed by analyzing from the pool water the presence of disinfection by-products (DBPs), such as: trihalomethanes (THMs), haloacetic acids (HAAs), chlorite, chlorate and bromate. The analytical results are in agreement with the Italian legislation (Accordo Stato-Regioni; 2003) even if in some of the sampled indoor swimming pools, the dosed combined chlorine levels, were greater than the Italian limit. With the regard to the microclimate conditions evaluation, the considered thermal indices, Predicted Mean Vote (PMV) and Predicted Percentage of Dissatisfied (PPD%), described a satisfactory occupational environment. Among DBPs, the THMs mean levels (41.4 +/- 30.0 microg/l) resulted close to the values of the current Italian drinking water legislation, and seem to not represent an health issue. The pool waters chlorate levels (range: 5 - 19537 microg/l) need further investigations as recent epidemiological studies on drinking water hypothesized a potential genotoxicity effect of these compounds which are involved in cellular oxidative processes.

  9. Occurrence and Spatial and Temporal Variations of Disinfection By-Products in the Water and Air of Two Indoor Swimming Pools

    PubMed Central

    Catto, Cyril; Sabrina, Simard; Ginette, Charest-Tardif; Manuel, Rodriguez; Robert, Tardif

    2012-01-01

    In order to improve disinfection by-product (DBP) exposure assessment, this study was designed to document both water and air levels of these chemical contaminants in two indoor swimming pools and to analyze their within-day and day-to-day variations in both of them. Intensive sampling was carried out during two one-week campaigns to measure trihalomethanes (THMs) and chloramines (CAMs) in water and air, and haloacetic acids (HAAs) in water several times daily. Water samples were systematically collected at three locations in each pool and air samples were collected at various heights around the pool and in other rooms (e.g., changing room) in the buildings. In addition, the ability of various models to predict air concentrations from water was tested using this database. No clear trends, but actual variations of contamination levels, appeared for both water and air according to the sampling locations and times. Likewise, the available models resulted in realistic but imprecise estimates of air contamination levels from water. This study supports the recommendation that suitable minimal air and water sampling should be carried out in swimming pools to assess exposure to DBPs. PMID:23066383

  10. Cryptosporidium and Giardia in recreational water in Belgium.

    PubMed

    Ehsan, Md Amimul; Casaert, Stijn; Levecke, Bruno; Van Rooy, Liesbet; Pelicaen, Joachim; Smis, Anne; De Backer, Joke; Vervaeke, Bart; De Smedt, Sandra; Schoonbaert, Filip; Lammens, Saskia; Warmoes, Thierry; Geurden, Thomas; Claerebout, Edwin

    2015-09-01

    The objective of this study was to investigate the presence of Cryptosporidium and Giardia in different recreational water bodies in Belgium and to estimate the infection risk associated with swimming and other recreational activities. Cryptosporidium oocysts and/or Giardia cysts were detected in three out of 37 swimming pools, seven out of 10 recreational lakes, two out of seven splash parks and four out of 16 water fountains. In the swimming pools no infection risk for Cryptosporidium could be calculated, since oocysts were only detected in filter backwash water. The risk of Giardia infection in the swimming pools varied from 1.13×10(-6) to 2.49×10(-6) per swim per person. In recreational lakes, the infection risk varied from 2.79×10(-5) to 5.74×10(-5) per swim per person for Cryptosporidium and from 7.04×10(-5) to 1.46×10(-4) for Giardia. For other outdoor water recreation activities the estimated infection risk was 5.71×10(-6) for Cryptosporidium and 1.47×10(-5) for Giardia. However, most positive samples in the recreational lakes belonged to species/genotypes that are either animal-specific or predominantly found in animals. No Cryptosporidium was found in splash parks and water fountains, but the presence of Giardia cysts suggests a risk for human infection. The infection risk of Giardia infection during a 3.5-minute visit to a splash park for children equalled 1.68×10(-4).

  11. Infections Unlikely to be Spread Through Swimming Pools

    MedlinePlus

    ... Swimming Facilities Historic CDC Design & Operation Manuals Operation & Maintenance 12 Steps for Prevention of Recreational Water Illnesses ... Privacy FOIA No Fear Act OIG 1600 Clifton Road Atlanta , GA 30329-4027 USA 800-CDC-INFO ( ...

  12. Do Go Near the Water

    ERIC Educational Resources Information Center

    Thomas, David G., Ed.

    1976-01-01

    A collection of eight articles explains that swimming is but one of the many aquatic sports that can take place in a swimming pool and that aquatic education is becoming an integral part of physical education programs. (MM)

  13. Making a Splash.

    ERIC Educational Resources Information Center

    Maland, Jim

    1998-01-01

    Presents a 10-step process that allows swimming-pool owners to objectively scrutinize their existing facility's needs, construction, and operation and maintenance budgets before renovating a structurally deficient or costly pool. Four examples of problems involving pool-renovation decision making are highlighted. (GR)

  14. Chemical Safety Alert: Safe Storage and Handling of Swimming Pool Chemicals

    EPA Pesticide Factsheets

    Hazards of pool water treatment and maintenance chemicals (e.g., chlorine), and the protective measures pool owners should take to prevent fires, toxic vapor releases, and injuries. Triggered by improper wetting, mixing, or self-reactivity over time.

  15. Further evidence for conditioned taste aversion induced by forced swimming.

    PubMed

    Masaki, Takahisa; Nakajima, Sadahiko

    2005-01-31

    A series of experiments with rats reported that aversion to a taste solution can be established by forced swimming in a water pool. Experiment 1 demonstrated that correlation of taste and swimming is a critical factor for this phenomenon, indicating associative (i.e., Pavlovian) nature of this learning. Experiment 2 showed that this learning obeys the Pavlovian law of strength, by displaying a positive relationship between the duration of water immersion in training and the taste aversion observed in subsequent testing. Experiment 3 revealed that swimming rather than being wet is the critical agent, because a water shower did not endow rats with taste aversion. Experiment 4 found that taste aversion was a positive function of water level of the pools in training (0, 12 or 32 cm). These results, taken together, suggest that energy expenditure caused by physical exercise might be involved in the development of taste aversion.

  16. Disinfection by-products and microbial contamination in the treatment of pool water with granular activated carbon.

    PubMed

    Uhl, W; Hartmann, C

    2005-01-01

    For swimming pools, it is generally agreed that free chlorine levels have to be maintained to guarantee adequate disinfection. Recommended free chlorine levels can vary between 0.3 and 0.6 mg/L in Germany and up to 3 mg/L in other countries. Bathers introduce considerable amounts of organic matter, mainly in the form of such as urine and sweat, into the pool water. As a consequence, disinfection byproducts (DBPs) are formed. Regulations in Germany recommend levels of combined chlorine of less than 0.2 mg/L and levels of trihalomethanes (THMs) of less than 20 microg/L. Haloacetic acids (HAAs), haloacetonitriles (HANs), chloropicrin and chloral hydrate are also detected in considerable amounts. However, these compounds are not regulated yet. Swimming pool staff and swimmers, especially athletes, are primarily exposed to these byproducts by inhalation and/or dermal uptake. In Germany, new regulations for swimming pool water treatment generally require the use of activated carbon. In this project, three different types of granular activated carbon (GAC) (one standard GAC, two catalytic GACs) are compared for their long time behaviour in pool water treatment. In a pilot plant operated with real swimming pool water, production and removal of disinfection byproducts (THMs, HAAs, AOXs), of biodegradable substances (AOC), of bacteria (Pseudomonas aeruginosa, Legionella, coliforms, HPC) as well as the removal of chlorine and chloramines are monitored as function of GAC bed depth. Combined chlorine penetrates deeper in the filter bed than free chlorine does. However, both, free and combined chlorine removal efficiencies decrease over the time of filter operation. The decreases of removal efficiencies are also observed for parameters such as dissolved organic carbon, spectral absorption coefficient, adsorbable organic carbon and most of the disinfection byproducts. However, THMs, especially chloroform are produced in the filter bed. The GAC beds were contaminated microbially, especially with P. aeruginosa. The contamination was not removable by backwashing with chlorine concentrations up to 2 mg/l free chlorine.

  17. Locomotion of bacteria in liquid flow and the boundary layer effect on bacterial attachment.

    PubMed

    Zhang, Chao; Liao, Qiang; Chen, Rong; Zhu, Xun

    2015-06-12

    The formation of biofilm greatly affects the performance of biological reactors, which highly depends on bacterial swimming and attachment that usually takes place in liquid flow. Therefore, bacterial swimming and attachment on flat and circular surfaces with the consideration of flow was studied experimentally. Besides, a mathematical model comprehensively combining bacterial swimming and motion with flow is proposed for the simulation of bacterial locomotion and attachment in flow. Both experimental and theoretical results revealed that attached bacteria density increases with decreasing boundary layer thickness on both flat and circular surfaces, the consequence of which is inherently related to the competition between bacterial swimming and the non-slip motion with flow evaluated by the Péclet number. In the boundary layer, where the Péclet number is relatively higher, bacterial locomotion mainly depends on bacterial swimming. Thinner boundary layer promotes bacterial swimming towards the surface, leading to higher attachment density. To enhance the performance of biofilm reactors, it is effective to reduce the boundary layer thickness on desired surfaces. Copyright © 2015 Elsevier Inc. All rights reserved.

  18. Acute changes in serum immune markers due to swimming in a chlorinated pool.

    PubMed

    Vlaanderen, Jelle; van Veldhoven, Karin; Font-Ribera, Laia; Villanueva, Cristina M; Chadeau-Hyam, Marc; Portengen, Lützen; Grimalt, Joan O; Zwiener, Christian; Heederik, Dick; Zhang, Xiangru; Vineis, Paolo; Kogevinas, Manolis; Vermeulen, Roel

    2017-08-01

    Exposure to disinfectants and disinfection byproducts (DBPs) due to swimming in chlorinated water has been associated with allergic and respiratory health effects, including asthma. Biological mechanisms contributing to these associations are largely unknown. We hypothesized a potential pathway involving modulation of the immune system. We assessed levels of immune markers (CCL11, CCL22, CXCL10, CRP, EGF, GCSF, IL-8, IL-17, IL-1RA, MPO, VEGF, Periostin) in serum collected from 30 women and 29 men before and after 40min of swimming in a chlorinated pool. Exposure to DBPs was assessed by measuring bromodichloromethane, bromoform, chloroform, and dibromochloromethane in exhaled breath before and after swimming. Covariate data including information on physical activity was available through questionnaires and measurements. We assessed the association between indicators of swimming in a chlorinated pool and changes in serum immune marker concentrations using linear regression with bivariate normal distributions and adjusted for multiple comparisons by applying the Benjamini-Hochberg procedure. We observed a significant decrease in serum concentrations of IL-8 (-12.53%; q=2.00e-03), CCL22 (-7.28%; q=4.00e-04), CCL11 (-7.15%; q=9.48e-02), CRP (-7.06%; q=4.68e-05), and CXCL10 (-13.03%; q=6.34e-14) and a significant increase in IL-1RA (20.16%; q=4.18e-06) from before to after swimming. Associations with quantitative measurements of DBPs or physical activity were similar in direction and strength. Most of the observed associations became non-significant when we adjusted the effects of exposure to DBPs for physical activity or vice-versa. Our study indicates that swimming in a chlorinated pool induces perturbations of the immune response through acute alterations of patterns of cytokine and chemokine secretion. The observed effects could not be uniquely attributed to either exposure to DBPs or physical activity. Evidence in the literature suggests that observed decreases in immune markers are possibly due to an immunosuppressive effect of DBPs, while the increase in IL-1RA might be due to physical activity. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. In the making: SA-PIV applied to swimming practice

    NASA Astrophysics Data System (ADS)

    van Houwelingen, Josje; van de Water, Willem; Kunnen, Rudie; van Heijst, Gertjan; Clercx, Herman

    2017-11-01

    To understand and optimize the propulsion in human swimming, a deep understanding of the hydrodynamics of swimming is required. This is usually based on experiments and numerical simulations under laboratory conditions.. In this study, we bring basic fluid mechanics knowledge and experimental measurement techniques to analyze the flow towards the swimming practice itself. A flow visualization setup is build and placed in a regular swimming pool. The measurement volume contains five homogeneous air bubble curtains illuminated by ambient light. The bubbles in these curtains act as tracer particles. The bubble motion is captured by six cameras placed in the side wall of the pool. It is intended to apply SA-PIV (synthetic aperture PIV) for analyzing the flow structures on multiple planes in the measurement volume. The system has been calibrated and the calibration data are used to refocus on the planes of interest. Multiple preprocessing steps need to be executed to obtain the proper quality of images before applying PIV. With a specially programmed video card to process and analyze the images in real-time feedback about swimming performance will become possible. We report on the first experimental data obtained by this system.

  20. Environmental and personal determinants of the uptake of disinfection by-products during swimming.

    PubMed

    Font-Ribera, Laia; Kogevinas, Manolis; Schmalz, Christina; Zwiener, Christian; Marco, Esther; Grimalt, Joan O; Liu, Jiaqi; Zhang, Xiangru; Mitch, William; Critelli, Rossana; Naccarati, Alessio; Heederik, Dick; Spithoven, Jack; Arjona, Lourdes; de Bont, Jeroen; Gracia-Lavedan, Esther; Villanueva, Cristina M

    2016-08-01

    Trihalomethanes (THMs) in exhaled breath and trichloroacetic acid (TCAA) in urine are internal dose biomarkers of exposure to disinfection by-products (DBPs) in swimming pools. We assessed how these biomarkers reflect the levels of a battery of DBPs in pool water and trichloramine in air, and evaluated personal determinants. A total of 116 adults swam during 40min in a chlorinated indoor pool. We measured chloroform, bromodichloromethane, dibromochloromethane and bromoform in exhaled breath and TCAA in urine before and after swimming, trichloramine in air and several DBPs in water. Personal determinants included sex, age, body mass index (BMI), distance swum, energy expenditure, heart rate and 12 polymorphisms in GSTT1, GSTZ1 and CYP2E1 genes. Median level of exhaled total THMs and creatinine adjusted urine TCAA increased from 0.5 to 14.4µg/m(3) and from 2.5 to 5.8µmol/mol after swimming, respectively. The increase in exhaled brominated THMs was correlated with brominated THMs, haloacetic acids, haloacetonitriles, haloketones, chloramines, total organic carbon and total organic halogen in water and trichloramine in air. Such correlations were not detected for exhaled chloroform, total THMs or urine TCAA. Exhaled THM increased more in men, urine TCAA increased more in women, and both were affected by exercise intensity. Genetic variants were associated with differential increases in exposure biomarkers. Our findings suggest that, although affected by sex, physical activity and polymorphisms in key metabolizing enzymes, brominated THMs in exhaled breath could be used as a non-invasive DBP exposure biomarker in swimming pools with bromide-containing source waters. This warrants confirmation with new studies. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. Safety Management for Water Play Facilities.

    ERIC Educational Resources Information Center

    Thompson, Claude

    1986-01-01

    Modern aquatic facilities, which include wave pools, water slides, and shallow water activity play pools, have a greater potential for injuries and lawsuits than conventional swimming pools. This article outlines comprehensive safety management for such facilities, including potential accident identification and injury control planning. (MT)

  2. Athlete's Foot

    MedlinePlus

    ... areas where the infection can spread, such as locker rooms, saunas, swimming pools, communal baths and showers ... sandals or shoes around public pools, showers and lockers rooms. Treat your feet. Use powder, preferably antifungal, ...

  3. Balancing the Energy Pendulum.

    ERIC Educational Resources Information Center

    MacKinnon, Sharon

    1987-01-01

    The city of Kitchener, Ontario, has installed a heat recovery loop in one indoor pool, all indoor swimming pools use pool covers, and two have solar heating. Energy is saved in two ice arenas by low-emissivity ceilings, and in the largest arena by a heat recovery system. (MLF)

  4. Locomotion of bacteria in liquid flow and the boundary layer effect on bacterial attachment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, Chao, E-mail: zhangchao@cqu.edu.cn; Institute of Engineering Thermophysics, Chongqing University, Chongqing 400030; Liao, Qiang, E-mail: lqzx@cqu.edu.cn

    The formation of biofilm greatly affects the performance of biological reactors, which highly depends on bacterial swimming and attachment that usually takes place in liquid flow. Therefore, bacterial swimming and attachment on flat and circular surfaces with the consideration of flow was studied experimentally. Besides, a mathematical model comprehensively combining bacterial swimming and motion with flow is proposed for the simulation of bacterial locomotion and attachment in flow. Both experimental and theoretical results revealed that attached bacteria density increases with decreasing boundary layer thickness on both flat and circular surfaces, the consequence of which is inherently related to the competitionmore » between bacterial swimming and the non-slip motion with flow evaluated by the Péclet number. In the boundary layer, where the Péclet number is relatively higher, bacterial locomotion mainly depends on bacterial swimming. Thinner boundary layer promotes bacterial swimming towards the surface, leading to higher attachment density. To enhance the performance of biofilm reactors, it is effective to reduce the boundary layer thickness on desired surfaces. - Highlights: • Study of bacterial locomotion in flow as an early stage in biofilm formation. • Mathematical model combining bacterial swimming and the motion with flow. • Boundary layer plays a key role in bacterial attachment under flow condition. • The competition between bacterial swimming and the motion with flow is evaluated.« less

  5. Isolated core training improves sprint performance in national-level junior swimmers.

    PubMed

    Weston, Matthew; Hibbs, Angela E; Thompson, Kevin G; Spears, Iain R

    2015-03-01

    To quantify the effects of a 12-wk isolated core-training program on 50-m front-crawl swim time and measures of core musculature functionally relevant to swimming. Twenty national-level junior swimmers (10 male and 10 female, 16±1 y, 171±5 cm, 63±4 kg) participated in the study. Group allocation (intervention [n=10], control [n=10]) was based on 2 preexisting swim-training groups who were part of the same swimming club but trained in different groups. The intervention group completed the core training, incorporating exercises targeting the lumbopelvic complex and upper region extending to the scapula, 3 times/wk for 12 wk. While the training was performed in addition to the normal pool-based swimming program, the control group maintained their usual pool-based swimming program. The authors made probabilistic magnitude-based inferences about the effect of the core training on 50-m swim time and functionally relevant measures of core function. Compared with the control group, the core-training intervention group had a possibly large beneficial effect on 50-m swim time (-2.0%; 90% confidence interval -3.8 to -0.2%). Moreover, it showed small to moderate improvements on a timed prone-bridge test (9.0%; 2.1-16.4%) and asymmetric straight-arm pull-down test (23.1%; 13.7-33.4%), and there were moderate to large increases in peak EMG activity of core musculature during isolated tests of maximal voluntary contraction. This is the first study to demonstrate a clear beneficial effect of isolated core training on 50-m front-crawl swim performance.

  6. Making a Splash.

    ERIC Educational Resources Information Center

    Ephron, Hazel; Bishop, Walter

    2001-01-01

    Explains why upgrading a school's pools can help reduce maintenance costs and make safer facilities. Three top engineering issues in older pools are addressed: recirculation, filtration, and dehumidification. Concluding comments discuss procedures for establishing safe swimming. (GR)

  7. Degradation of Organic UV filters in Chlorinated Seawater Swimming Pools: Transformation Pathways and Bromoform Formation.

    PubMed

    Manasfi, Tarek; Coulomb, Bruno; Ravier, Sylvain; Boudenne, Jean-Luc

    2017-12-05

    Organic ultraviolet (UV) filters are used in sunscreens and other personal-care products to protect against harmful effects of exposure to UV solar radiation. Little is known about the fate of UV filters in seawater swimming pools disinfected with chlorine. The present study investigated the occurrence and fate of five commonly used organic UV filters, namely dioxybenzone, oxybenzone, avobenzone, 2-ethylhexyl-4-methoxycinnamate, and octocrylene, in chlorinated seawater swimming pools. Pool samples were collected to monitor the variation of UV filter concentrations during pool opening hours. Furthermore, laboratory-controlled chlorination experiments were conducted in seawater spiked with UV filters to investigate the reactivity of UV filters. Extracts of chlorination reaction samples were analyzed using high-resolution mass spectrometry and electron-capture detection to identify the potentially formed byproducts. In the collected pool samples, all the UV filters except dioxybenzone were detected. Chlorination reactions showed that only octocrylene was stable in chlorinated seawater. The four reactive UV filters generated brominated transformation products and disinfection byproducts. This formation of brominated products resulted from reactions between the reactive UV filters and bromine, which is formed rapidly when chlorine is added to seawater. Based on the identified byproducts, the transformation pathways of the reactive UV filters were proposed for the first time. Bromoform was generated by all the reactive UV filters at different yields. Bromal hydrate was also detected as one of the byproducts generated by oxybenzone and dioxybenzone.

  8. 21 CFR 1250.89 - Swimming pools.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... equipped so as to provide complete circulation, replacement, and filtration of the water in the pool every six hours or less. Suitable means of chlorination and, if necessary, other treatment of the water shall be provided to maintain the residual chlorine in the pool water at not less than 0.4 part per...

  9. 21 CFR 1250.89 - Swimming pools.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... equipped so as to provide complete circulation, replacement, and filtration of the water in the pool every six hours or less. Suitable means of chlorination and, if necessary, other treatment of the water shall be provided to maintain the residual chlorine in the pool water at not less than 0.4 part per...

  10. Final Environmental Assessment (EA) for the Revitalization of Military Family Housing Keesler AFB, MS

    DTIC Science & Technology

    2006-03-01

    12,000 square feet each). An Olympic-size swimming pool (approximately 71 feet by 164 feet). Twelve covered bus stops. A skateboard park...11,644 Covered Bus Stop 100 12 1,200 Skateboard Park 10,890 1 10,890 Storage Unit 100 534 53,400 Total N/A N/A 125,134 Location to be determined...Olympic-size Swimming Pool 1 1 Covered Bus Stop 5 4 3 12 Skateboard Park 1 1 Storage Unit 0 294 160 80 534 2.6 ALTERNATIVE 1 (IMMEDIATE

  11. Microcrustacea in flowing water - experimental-analysis of washout times and a field-test

    USGS Publications Warehouse

    Richardson, W.B.

    1992-01-01

    1. Flow-chamber experiments were conducted to evaluate the ability of microcrustacea to maintain position in moving water. These results were compared to distributions of zooplankton and water velocity in a stream pool to determine the relationship of animal density to water movement and swimming ability.^2. Cladocerans exhibited negative rheotaxis (directed behaviour against a current) but poor ability to maintain position at velocities >2.5 Cm s-1. Daphnia and scapholeberis were better at avoiding washout than moina and diaphanosoma. At velocities 2.5 Cm s-1, scapholeberis >3.2 Cm s-1 and eucyclops >7.75 Cm s-1. Washout time of daphnia and scapholeberis was positively related to body size and negatively to water velocity and possession of eggs. Washout was inversely related to water velocity for eucyclops.^4. Highest densities of microcrustacea in a stream pool were found in non-flowing or downstream zones of the pool. Benthic (hydracarina, harpacticoid copepods, ostracods) and fast-swimming (cyclopoids) forms were most common in flowing zones. Facultatively benthic cladocera were abundant in regions of no flow. Rotifers and immature copepods were most abundant at the downstream end of the pool.^5. Behavioural mechanisms for remaining in stream pools at times of high flow appear to include: (i) flow avoidance (simocephalus, chydorus, scapholeberis and cyclopoids), (ii) use of benthic habitat (ostracods, harpacticoids, hydracarina), (iii) strong swimming ability (cyclopoids).

  12. Safety Barrier Guidelines for Home Pools [and] How To Plan for the Unexpected.

    ERIC Educational Resources Information Center

    Consumer Product Safety Commission, Washington, DC.

    Each year, hundreds of young children die and thousands come close to death due to submersion in residential swimming pools. The United States Consumer Products Safety Commission studied data on drownings and child behavior, as well as information on pool and pool barrier construction, and concluded that the best way to reduce child drownings in…

  13. Decontamination of outdoor school swimming pools in Fukushima after the nuclear accident in March 2011.

    PubMed

    Saegusa, J; Kurikami, H; Yasuda, R; Kurihara, K; Arai, S; Kuroki, R; Matsuhashi, S; Ozawa, T; Goto, H; Takano, T; Mitamura, H; Nagano, T; Naganawa, H; Yoshida, Z; Funaki, H; Tokizawa, T; Nakayama, S

    2013-03-01

    Because of radioactive fallout resulting from the Fukushima Daiichi Nuclear Power Plant (NPP) accident, water discharge from many outdoor swimming pools in Fukushima was suspended out of concern that radiocesium in the pool water would flow into farmlands. The Japan Atomic Energy Agency has reviewed the existing flocculation method for decontaminating pool water and established a practical decontamination method by demonstrating the process at eight pools in Fukushima. In this method, zeolite powder and a flocculant are used for capturing radiocesium present in pool water. The supernatant is discharged if the radiocesium concentration is less than the targeted level. The radioactive residue is collected and stored in a temporary storage space. Radioactivity concentration in water is measured with a NaI(Tl) or Ge detector installed near the pool. The demonstration results showed that the pool water in which the radiocesium concentration was more than a few hundred Bq L was readily purified by the method, and the radiocesium concentration was reduced to less than 100 Bq L. The ambient dose rates around the temporary storage space were slightly elevated; however, the total increase was up to 30% of the background dose rates when the residue was shielded with sandbags.

  14. Removals of cryptosporidium parvum oocysts and cryptosporidium-sized polystyrene microspheres from swimming pool water by diatomaceous earth filtration and perlite-sand filtration.

    PubMed

    Lu, Ping; Amburgey, James E; Hill, Vincent R; Murphy, Jennifer L; Schneeberger, Chandra L; Arrowood, Michael J; Yuan, Tao

    2017-06-01

    Removal of Cryptosporidium-sized microspheres and Cryptosporidium parvum oocysts from swimming pools was investigated using diatomaceous earth (DE) precoat filtration and perlite-sand filtration. In pilot-scale experiments, microsphere removals of up to 2 log were obtained with 0.7 kg·DE/m 2 at a filtration rate of 5 m/h. A slightly higher microsphere removal (2.3 log) was obtained for these DE-precoated filters when the filtration rate was 3.6 m/h. Additionally, pilot-scale perlite-sand filters achieved greater than 2 log removal when at least 0.37 kg/m 2 of perlite was used compared to 0.1-0.4 log removal without perlite both at a surface loading rate of 37 m/h. Full-scale testing achieved 2.7 log of microspheres and oocysts removal when 0.7 kg·DE/m 2 was used at 3.6 m/h. Removals were significantly decreased by a 15-minute interruption of the flow (without any mechanical agitation) to the DE filter in pilot-scale studies, which was not observed in full-scale filters. Microsphere removals were 2.7 log by perlite-sand filtration in a full-scale swimming pool filter operated at 34 m/h with 0.5 kg/m 2 of perlite. The results demonstrate that either a DE precoat filter or a perlite-sand filter can improve the efficiency of removal of microspheres and oocysts from swimming pools over a standard sand filter under the conditions studied.

  15. Do food and physical activity environments vary between disadvantaged urban and rural areas? Findings from the READI Study.

    PubMed

    Thornton, Lukar E; Crawford, David A; Cleland, Verity J; Timperio, Anna F; Abbott, Gavin; Ball, Kylie

    2012-08-01

    The presence or absence of amenities in local neighbourhood environments can either promote or restrict access to opportunities to engage in healthy and/or less healthy behaviours. Rurality is thought to constrain access to facilities and services. This study investigated whether the presence and density of environmental amenities related to physical activity and eating behaviours differs between socioeconomically disadvantaged urban and rural areas in Victoria, Australia. We undertook cross-sectional analysis of environmental data collected in 2007-08 as part of the Resilience for Eating and Activity Despite Inequality (READI) study. These data were sourced and analysed for 40 urban and 40 rural socioeconomically disadvantaged areas. The variables examined were the presence, raw count, count/km2, and count/'000 population of a range of environmental amenities (fast-food restaurants, all supermarkets (also separated by major chain and other supermarkets), greengrocers, playgrounds, gyms/leisure centres, public swimming pools and public open spaces). A greater proportion of urban areas had a fast-food restaurant and gym/leisure centre present while more rural areas contained a supermarket and public swimming pool. All amenities examined (with the exception of swimming pools) were more numerous per km2 in urban areas, however rural areas had a greater number of all supermarkets, other supermarkets, playgrounds, swimming pools and public open space per '000 population. Although opportunities to engage in healthy eating and physical activity exist in many rural areas, a lower density per km2 suggests a greater travel distance may be required to reach these.

  16. The Role of School Environment in Physical Activity among Brazilian Adolescents.

    PubMed

    de Rezende, Leandro Fórnias Machado; Azeredo, Catarina Machado; Silva, Kelly Samara; Claro, Rafael Moreira; França-Junior, Ivan; Peres, Maria Fernanda Tourinho; Luiz, Olinda do Carmo; Levy, Renata Bertazzi; Eluf-Neto, José

    2015-01-01

    To analyze the association of physical activity facilities and extracurricular sports activities in schools with physical activity among adolescents. We used data collected for the National Survey of School Health in 2012. The national representative sample comprised 109,104 Brazilian students from 2,842 schools. We calculated the prevalence of participation in physical education classes, leisure-time physical activity, and total physical activity level. We also evaluated the following physical activity facilities: sports courts, running/athletics tracks, schoolyard with teacher-directed physical activities, swimming pools, locker rooms; and the offer of extracurricular sports activities. Schools with at least one physical activity facility had increased odds of participation in physical education (OR 1.59; 95% CI 1.20 to 2.10). However, in order to increase leisure-time physical activity (OR1.14; 95% CI 1.03 to 1.26) and total physical activity level (OR 1.15; 95% CI 1.06 to 1.24) at least four and two facilities, respectively, were necessary. Extracurricular sports activities in schools were positively associated with leisure-time physical activity and physical activity level. The number of sports courts and swimming pool in a school were associated with participation in physical education classes. Availability of sports courts, running/athletics tracks, and swimming pool in schools were associated with leisure-time physical activity. Total physical activity was associated with schools with sports courts, schoolyard with teacher-directed physical activities, and swimming pool. School-level characteristics have important potential to increase the possibility of engagement in physical activity in and out of school, and therefore have a fundamental role in promoting these practices.

  17. Targeted Recruitment for Naval Special Warfare (SEALS): Connecting NSW to Recruit Pools with Social Movement Theory

    DTIC Science & Technology

    2012-06-01

    water polo, triathlon, lacrosse, boxing rugby , and swimming as well as those participating in activities such as mountain biking, woodworking...participated in any of the following sports: water polo, triathlon, lacrosse, boxing rugby , and swimming. Also controlled for is the level of a...strong sport attribute. The sports within this strong sport variable are water polo, triathlon, lacrosse, boxing, rugby , and swimming. Each of these

  18. Increased exhaled breath condensate 8-isoprostane after a swimming session in competitive swimmers.

    PubMed

    Morissette, Mathieu C; Murray, Nicolas; Turmel, Julie; Milot, Julie; Boulet, Louis-Philippe; Bougault, Valérie

    2016-08-01

    This study aimed to evaluate the levels of 8-isoprostane (8-IsoP) in the airways of competitive swimmers at baseline and after a swimming session according to their airway responsiveness. Twenty-three swimmers and six lifeguards had a baseline spirometry and bronchoprovocative challenges. During a second visit, swimmers performed a usual swimming session while lifeguards stayed in the same pool environment for the same time period. Forced expiratory volume in one second (FEV1) was measured before and 5 min after the end of the session. Exhaled breath condensate (EBC) was sampled before and 10 min after the session and EBC 8-IsoP levels were analysed by enzyme immunoassay. Change in EBC 8-IsoP from baseline to post-swimming session was calculated. We observed no relationships between airway hyper-responsiveness and 8-IsoP values before or after swimming in swimmers. The levels of 8-IsoP were significantly higher after the training session (mean value 2.9, s = 0.5 pg mL(-1)) than at baseline (mean value 1.9, s = 0.4 pg mL(-1)) in swimmers only (p = .012). EBC 8-IsoP levels after the swimming session significantly correlated with the percent change in FEV1 after swimming. EBC 8-IsoP levels were increased after training in swimmers but not in lifeguards, suggesting that exercise-induced hyperpnoea in a chlorinated pool environment increases airways oxidative stress.

  19. "Hot tub" Folliculitis from a nonchlorinated children's pool.

    PubMed

    Segna, Kara G; Koch, Laine H; Williams, Judith V

    2011-01-01

    Pseudomonas aeruginosa is common cause of folliculitis following contact with contaminated water. We report a case of pseudomonal folliculitis that occurred after swimming in a children's pool filled with water from a well. © 2011 Wiley Periodicals, Inc.

  20. RELAP5 Analysis of the Hybrid Loop-Pool Design for Sodium Cooled Fast Reactors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hongbin Zhang; Haihua Zhao; Cliff Davis

    2008-06-01

    An innovative hybrid loop-pool design for sodium cooled fast reactors (SFR-Hybrid) has been recently proposed. This design takes advantage of the inherent safety of a pool design and the compactness of a loop design to improve economics and safety of SFRs. In the hybrid loop-pool design, primary loops are formed by connecting the reactor outlet plenum (hot pool), intermediate heat exchangers (IHX), primary pumps and the reactor inlet plenum with pipes. The primary loops are immersed in the cold pool (buffer pool). Passive safety systems -- modular Pool Reactor Auxiliary Cooling Systems (PRACS) – are added to transfer decay heatmore » from the primary system to the buffer pool during loss of forced circulation (LOFC) transients. The primary systems and the buffer pool are thermally coupled by the PRACS, which is composed of PRACS heat exchangers (PHX), fluidic diodes and connecting pipes. Fluidic diodes are simple, passive devices that provide large flow resistance in one direction and small flow resistance in reverse direction. Direct reactor auxiliary cooling system (DRACS) heat exchangers (DHX) are immersed in the cold pool to transfer decay heat to the environment by natural circulation. To prove the design concepts, especially how the passive safety systems behave during transients such as LOFC with scram, a RELAP5-3D model for the hybrid loop-pool design was developed. The simulations were done for both steady-state and transient conditions. This paper presents the details of RELAP5-3D analysis as well as the calculated thermal response during LOFC with scram. The 250 MW thermal power conventional pool type design of GNEP’s Advanced Burner Test Reactor (ABTR) developed by Argonne National Laboratory was used as the reference reactor core and primary loop design. The reactor inlet temperature is 355 °C and the outlet temperature is 510 °C. The core design is the same as that for ABTR. The steady state buffer pool temperature is the same as the reactor inlet temperature. The peak cladding, hot pool, cold pool and reactor inlet temperatures were calculated during LOFC. The results indicate that there are two phases during LOFC transient – the initial thermal equilibration phase and the long term decay heat removal phase. The initial thermal equilibration phase occurs over a few hundred seconds, as the system adjusts from forced circulation to natural circulation flow. Subsequently, during long-term heat removal phase all temperatures evolve very slowly due to the large thermal inertia of the primary and buffer pool systems. The results clearly show that passive safety PRACS can effectively transfer decay heat from the primary system to the buffer pool by natural circulation. The DRACS system in turn can effectively transfer the decay heat to the environment.« less

  1. Pool Purification

    NASA Technical Reports Server (NTRS)

    1988-01-01

    Caribbean Clear, Inc. used NASA's silver ion technology as a basis for its automatic pool purifier. System offers alternative approach to conventional purification chemicals. Caribbean Clear's principal markets are swimming pool owners who want to eliminate chlorine and bromine. Purifiers in Caribbean Clear System are same silver ions used in Apollo System to kill bacteria, plus copper ions to kill algae. They produce spa or pool water that exceeds EPA Standards for drinking water.

  2. Assessment of air and water contamination by disinfection by-products at 41 indoor swimming pools.

    PubMed

    Tardif, Robert; Catto, Cyril; Haddad, Sami; Simard, Sabrina; Rodriguez, Manuel

    2016-07-01

    This study was aimed at assessing the profiles (occurrence and speciation) of disinfection by-product (DBP) contamination in air and water of a group of 41 public indoor swimming pools in Québec (Canada). The contaminants measured in the water included the traditional DBPs [i.e., four trihalomethanes (THMs), six haloacetic acids (HAAs)] but also several emergent DBPs [i.e., halonitriles, halonitromethanes, haloketones and nitrosodimethylamine (NDMA)]. Those measured in the air comprised THMs and chloramines (CAMs). Overall, extremely variable DBP levels were found from one pool to another (both quantitatively and in terms of speciation). For instance, in water, among the four THMs, chloroform was usually the most abundant compound (37.9±25.7µg/L). Nevertheless, the sum of the three other brominated THMs represented more than 25% of total THMs at almost half the facilities visited (19 cases). In 13 of them, the levels of brominated THMs (66±24.2µg/L) even greatly outweighed the levels of chloroform (15.2±6.31µg/L). Much higher levels of HAAs (294.8±157.6µg/L) were observed, with a consistent preponderance of brominated HAAs in the swimming pools with more brominated THMs. NDMA levels which were measured in a subset of 8 pools ranged between 2.8ng/L and 105ng/L. With respect to air, chloroform was still the most abundant THM globally (119.4±74.2µg/m(3)) but significant levels of brominated THMs were also observed in various cases, particularly in the previously evoked group of 13 swimming pools with preponderant levels of brominated THMs in water. CAM levels (0.23±0.15mg/m(3)) varied highly, ranging from not detected to 0.56mg/m(3). Overall, the levels were generally relatively high compared to current guidelines or reference values from several countries, and they point to a relatively atypical presence of brominated compounds, and to significant levels of emergent DBPs for which health risk is less documented. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Assessment of swimmer behaviors on pool water ingestion

    EPA Science Inventory

    Enteric pathogens in pool water can be unintentionally ingested during swimming, increasing the likelihood of acute gastrointestinal illness(AGI). AGI cases in outbreaks are more likely to submerge heads than non-cases, but an association is unknown since outbreak data are self-r...

  4. Prevention of needless deaths from drowning.

    PubMed

    Modell, Jerome H

    2010-07-01

    To determine whether faulty pool maintenance and substandard lifeguard performance critically delayed retrieval and resuscitation of a significant number of pool drowning victims. One hundred and eighty drowning incidents that resulted in litigation from 1998 to 2008 were studied to determine whether faulty pool maintenance and/or substandard lifeguard performance delayed retrieval and thereby contributed to the death of these persons. A total of 180 swimming pools-commercial and private-were included. Ninety-seven of these pools were manned by lifeguards. Subjects who underwent the drowning process and suffered severe brain injury or death were reviewed to determine the rescue and resuscitation attempts by lifeguards or bystanders at the pool. One hundred and seventy-seven of the 180 persons who underwent the drowning process died. Cases were analyzed as to whether faulty pool maintenance and/or substandard lifeguard performance contributed to their demise. At fault were cloudy or dirty water; drain pipes that created underwater suction to trap victims; inadequate fencing around pools through which small children gained access; permitting small children to be at the pool without adult supervision; permitting dangerous exercises such as hyperventilation while underwater swimming, resulting in shallow water blackout; lifeguards not being attentive, being distracted by other persons, performing nonrelated chores, leaving their positions without proper relief, while failure to enter the water when told persons were submerged. Faculty pool maintenance and substandard lifeguard performance critically delayed retrieval and resuscitation of a significant number of pool drowning victims.

  5. Statistical evaluation of potential damage to the Al(OH)3 layer on nTiO2 particles in the presence of swimming pool and seawater

    NASA Astrophysics Data System (ADS)

    Virkutyte, Jurate; Al-Abed, Souhail R.

    2012-03-01

    Nanosized TiO2 particles (nTiO2) are usually coated with an Al(OH)3 layer when used in sunscreen to shield against the harmful effects of free radicals that are generated when these particles are exposed to UV radiation. Therefore, it is vital to insure the structural stability of these particles in the environment where the protective layer may be damaged and adverse health and environmental effects can occur. This study utilized X-ray analysis (SEM-EDS) to provide a qualitative and semi-quantitative assessment of the chemical and physical characteristics of Al(OH)3-coated original and damaged nTiO2 particles (used in sunscreen lotion formulations) in the presence of both swimming pool and seawater. Also, by utilizing statistical tools, a distribution of Al/Ti (%) on the particle surface was determined and evaluated. It was found that 45 min of treatment with swimming pool and seawater significantly induced the redistribution of Al/Ti (%), which changed the surface characteristics of particles and, therefore, may have induced undesired photo-activity and the consequent formation of free radicals.

  6. A Pilot Study of the Validity of Self-reported Ultraviolet Radiation Exposure and Sun Protection Practices Among Lifeguards, Parents and Children

    PubMed Central

    O’Riordan, David L.; Glanz, Karen; Gies, Peter; Elliott, Tom

    2013-01-01

    Outdoor recreation settings, such as swimming pools, provide a promising venue to assess UVR exposure and sun protection practices among individuals who are minimally clothed and exposed to potentially high levels of UVR. Most studies assessing sun exposure/protection practices rely on self-reported data, which are subject to bias. The aim of this study was to establish the feasibility of conducting a multimethod study to examine the validity of self-reported measures within a swimming pool setting. Data were collected from 27 lifeguards, children and parents in Hawaii. Each participant filled out a survey and a 4 day sun habits diary. On two occasions, researchers assessed observable sun protection behaviors (wearing hats, shirts, sunglasses), swabbed the skin to detect the presence of sunscreen, and subjects wore polysulphone dosimeters to measure UVR exposure. Overall, observed sun protection behaviors were more highly correlated with diary reports than with survey reports. While lifeguards and children reported spending comparable amounts of time in the sun, dosimeter measures showed that lifeguards received twice as much UVR exposure. This study demonstrated the feasibility of implementing a multimethod validity study within a broader population of swimming pools. PMID:18179624

  7. Getting Pool Light Right.

    ERIC Educational Resources Information Center

    Hunsaker, Scot

    1998-01-01

    Examines the use of lighting, both artificial and natural, that can enhance the aesthetic quality and functionality of areas with indoor swimming pools. Discusses glare and shadow-reduction measures that aid competitive events, including lighting above and below water levels, and highlights lighting issues during televised events. Descriptions of…

  8. An approach to optimised control of HVAC systems in indoor swimming pools

    NASA Astrophysics Data System (ADS)

    Ribeiro, Eliseu M. A.; Jorge, Humberto M. M.; Quintela, Divo A. A.

    2016-04-01

    Indoor swimming pools are recognised as having a high level of energy consumption and present a great potential for energy saving. The energy is spent in several ways such as evaporation heat loss from the pool, high rates of ventilation required to guarantee the indoor air quality, and ambient temperatures with expressive values (typically 28-30°C) required to maintain conditions of comfort. This paper presents an approach to optimising control of heat ventilation and air conditioning systems that could be implemented in a building energy management system. It is easily adapted to any kind of pool and results in significant energy consumption reduction. The development and validation of the control model were carried out with a building thermal simulation software. The use of this control model in the case study building could reduce the energy efficiency index by 7.14 points (7.4% of total) which adds up to an energy cost saving of 15,609€ (7.5% of total).

  9. Mapping Neglected Swimming Pools from Satellite Data for Urban Vector Control

    NASA Astrophysics Data System (ADS)

    Barker, C. M.; Melton, F. S.; Reisen, W. K.

    2010-12-01

    Neglected swimming pools provide suitable breeding habit for mosquitoes, can contain thousands of mosquito larvae, and present both a significant nuisance and public health risk due to their inherent proximity to urban and suburban populations. The rapid increase and sustained rate of foreclosures in California associated with the recent recession presents a challenge for vector control districts seeking to identify, treat, and monitor neglected pools. Commercial high resolution satellite imagery offers some promise for mapping potential neglected pools, and for mapping pools for which routine maintenance has been reestablished. We present progress on unsupervised classification techniques for mapping both neglected pools and clean pools using high resolution commercial satellite data and discuss the potential uses and limitations of this data source in support of vector control efforts. An unsupervised classification scheme that utilizes image segmentation, band thresholds, and a change detection approach was implemented for sample regions in Coachella Valley, CA and the greater Los Angeles area. Comparison with field data collected by vector control personal was used to assess the accuracy of the estimates. The results suggest that the current system may provide some utility for early detection, or cost effective and time efficient annual monitoring, but additional work is required to address spectral and spatial limitations of current commercial satellite sensors for this purpose.

  10. Methods for measurement of energy expenditure and substrate concentrations in swimming rats.

    PubMed

    Benthem, L; Bolhuis, J W; van der Leest, J; Steffens, A B; Zock, J P; Zijlstra, W G

    1994-07-01

    A measuring system is described for the determination of oxygen consumption (Vo2) and carbon dioxide production (Vco2) in swimming rats. Vo2 and Vco2 were measured by means of an O2-analyzer (Ametek S3A) and a mass spectrometer (Balzers QMG 511), respectively, combined with a gas flow meter. The measurements were made in a 5-1 metabolic chamber on top of a swimming pool in which a water flow of 0.22 m/s was maintained. The rats were fitted with an indwelling catheter with its tip at the entrance of the right atrium for the repeated determination of energy substrate and hormone concentrations, before, during, and after swimming. The inaccuracy of the Vo2 and Vco2 measurements was 0.18% and 0.31% of the reading, respectively; the imprecision was 2.15% and 2.59%. This high accuracy and precision of the system was attained by measuring room air for 20 s after each 100 s of measuring air from the metabolic chamber, and by using demineralized water in the swimming pool. Vo2 during steady-state swimming was 1.89 +/- 0.06 mmol/kg.min (ca. 60% Vo2max), indicating moderate exercise. Respiratory quotient (RQ), during steady-state exercise, was 0.80 +/- 0.01. Vo2 and RQ resulted in rates for carbohydrate and fat utilization of 15.6 +/- 0.8 and 15.1 +/- 0.7 mg/kg.min, respectively.

  11. Deep and shallow water effects on developing preschoolers' aquatic skills.

    PubMed

    Costa, Aldo M; Marinho, Daniel A; Rocha, Helena; Silva, António J; Barbosa, Tiago M; Ferreira, Sandra S; Martins, Marta

    2012-05-01

    The aim of the study was to assess deep and shallow water teaching methods in swimming lessons for preschool children and identify variations in the basic aquatic skills acquired. The study sample included 32 swimming instructors (16 from deep water programs and 16 from shallow water programs) and 98 preschool children (50 from deep water swimming pool and 48 from shallow water swimming pool). The children were also studied regarding their previous experience in swimming (6, 12 and 18 months or practice). Chi-Square test and Fisher's exact test were used to compare the teaching methodology. A discriminant analysis was conducted with Λ wilk's method to predict under what conditions students are better or worse (aquatic competence). Results suggest that regardless of the non-significant variations found in teaching methods, the water depth can affect aquatic skill acquisition - shallow water lessons seem to impose greater water competence particularly after 6 months of practice. The discriminant function revealed a significant association between groups and all predictors for 6 months of swimming practice (p<0.001). Body position in gliding and leg displacements were the main predictors. For 12 and 18 months of practice, the discriminant function do not revealed any significant association between groups. As a conclusion, it seems that the teaching methodology of aquatic readiness based on deep and shallow water programs for preschoolers is not significantly different. However, shallow water lessons could be preferable for the development of basic aquatic skills.

  12. Deep and Shallow Water Effects on Developing Preschoolers’ Aquatic Skills

    PubMed Central

    Costa, Aldo M.; Marinho, Daniel A.; Rocha, Helena; Silva, António J.; Barbosa, Tiago M.; Ferreira, Sandra S.; Martins, Marta

    2012-01-01

    The aim of the study was to assess deep and shallow water teaching methods in swimming lessons for preschool children and identify variations in the basic aquatic skills acquired. The study sample included 32 swimming instructors (16 from deep water programs and 16 from shallow water programs) and 98 preschool children (50 from deep water swimming pool and 48 from shallow water swimming pool). The children were also studied regarding their previous experience in swimming (6, 12 and 18 months or practice). Chi-Square test and Fisher’s exact test were used to compare the teaching methodology. A discriminant analysis was conducted with Λ wilk’s method to predict under what conditions students are better or worse (aquatic competence). Results suggest that regardless of the non-significant variations found in teaching methods, the water depth can affect aquatic skill acquisition - shallow water lessons seem to impose greater water competence particularly after 6 months of practice. The discriminant function revealed a significant association between groups and all predictors for 6 months of swimming practice (p<0.001). Body position in gliding and leg displacements were the main predictors. For 12 and 18 months of practice, the discriminant function do not revealed any significant association between groups. As a conclusion, it seems that the teaching methodology of aquatic readiness based on deep and shallow water programs for preschoolers is not significantly different. However, shallow water lessons could be preferable for the development of basic aquatic skills. PMID:23487406

  13. 16 CFR 1207.5 - Design.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... pool slide shall be such that no structural failures of any component part shall cause failures of any... such fasteners shall not cause a failure of the tread under the ladder loading conditions specified in... without failure or permanent deformation. (d) Handrails. Swimming pool slide ladders shall be equipped...

  14. 16 CFR 1207.5 - Design.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... pool slide shall be such that no structural failures of any component part shall cause failures of any... such fasteners shall not cause a failure of the tread under the ladder loading conditions specified in... without failure or permanent deformation. (d) Handrails. Swimming pool slide ladders shall be equipped...

  15. Preliminary Consideration of the ADS Research in China

    NASA Astrophysics Data System (ADS)

    Fang, Shouxian; Fu, Shinian

    2002-08-01

    Power supply is a key issue for China's further economic development. To meet the needs of our economic growth in the next century, the part of nuclear energy in the total newly increased power supply must become larger. However, the present nuclear power stations dominated by the PWR in the world are facing some troubles. Recently, a new concept, called ADS (Accelerator Driven Subcritical system), can avoid these troubles and it is recognized as a most prospective power system for fission energy. So during the early time of nuclear power development in our country, it is worthwhile to exploit this novel idea. In this paper, the ADS research program and a proposed verification facility are described. It consists of an 300MeV/3mA low energy accelerator, a swimming pool reactor and some basic research equipment. Beam physics, such as beam halo formation, in the intense-beam accelerator is also discussed.

  16. Composite space charge density functions for the calculation of gamma sensitivity of self-powered neutron detectors, using Warren's model

    NASA Astrophysics Data System (ADS)

    Mahant, A. K.; Rao, P. S.; Misra, S. C.

    1994-07-01

    In the calculational model developed by Warren and Shah for the computation of the gamma sensitivity ( Sγ) it has been observed that the computed Sγ value is quite sensitive to the space charge distribution function assumed for the insulator region and the energy of the gamma photons. The Sγ of SPNDs with Pt, Co and V emitters (manufactured by Thermocoax, France) has been measured at 60Co photon energy and a good correlation between the measured and computed values has been obtained using a composite space charge density function (CSCD), the details of which are presented in this paper. The arguments are extended for evaluating the Sγ values of several SPNDs for which Warren and Shah reported the measured values for a prompt fission gamma spectrum obtained in a swimming pool reactor. These results are also discussed.

  17. 'Right Now, Sophie (∗)Swims in the Pool?!': Brain Potentials of Grammatical Aspect Processing.

    PubMed

    Flecken, Monique; Walbert, Kelly; Dijkstra, Ton

    2015-01-01

    We investigated whether brain potentials of grammatical aspect processing resemble semantic or morpho-syntactic processing, or whether they instead are characterized by an entirely distinct pattern in the same individuals. We studied aspect from the perspective of agreement between the temporal information in the context (temporal adverbials, e.g., Right now) and a morpho-syntactic marker of grammatical aspect (e.g., progressive is swimming). Participants read questions providing a temporal context that was progressive (What is Sophie doing in the pool right now?) or habitual (What does Sophie do in the pool every Monday?). Following a lead-in sentence context such as Right now, Sophie…, we measured event-related brain potentials (ERPs) time-locked to verb phrases in four different conditions, e.g., (a) is swimming (control); (b) (∗)is cooking (semantic violation); (c) (∗)are swimming (morpho-syntactic violation); or (d)?swims (aspect mismatch); …in the pool." The collected ERPs show typical N400 and P600 effects for semantics and morpho-syntax, while aspect processing elicited an Early Negativity (250-350 ms). The aspect-related Negativity was short-lived and had a central scalp distribution with an anterior onset. This differentiates it not only from the semantic N400 effect, but also from the typical LAN (Left Anterior Negativity), that is frequently reported for various types of agreement processing. Moreover, aspect processing did not show a clear P600 modulation. We argue that the specific context for each item in this experiment provided a trigger for agreement checking with temporal information encoded on the verb, i.e., morphological aspect marking. The aspect-related Negativity obtained for aspect agreement mismatches reflects a violated expectation concerning verbal inflection (in the example above, the expected verb phrase was Sophie is X-ing rather than Sophie X-s in condition d). The absence of an additional P600 for aspect processing suggests that the mismatch did not require additional reintegration or processing costs. This is consistent with participants' post hoc grammaticality judgements of the same sentences, which overall show a high acceptability of aspect mismatch sentences.

  18. Rummler's Swim Lanes in a Dutch Swimming Pool

    ERIC Educational Resources Information Center

    Bloem, Michiel; Vermei, Arnoud

    2009-01-01

    The work of Geary A. Rummler changed the way we think and act as performance professionals. Over the past 15 years, we have applied his tools and models in performance improvement projects in a variety of industries. Similar to the pioneers of our field 40 years ago, we were driven by curiosity when we took Rummler's work to the unusual…

  19. Adaptive Devices for Aquatic Activities.

    ERIC Educational Resources Information Center

    Bradtke, Jane Silverman

    1979-01-01

    The article describes commercial as well as improvised and homemade equipment for teaching physically handicapped persons to swim. Descriptions address equipment for entering the pool (such as pool lifts, a transfer board, and a ramp); aids in the instructional process (kick boards, arm floats); and assorted games and materials (such as ropes,…

  20. The 'Negligence' Buck Stops with You!

    ERIC Educational Resources Information Center

    Stern, James

    1982-01-01

    The owner or operator of a public swimming pool is legally responsible for the health and safety of patrons who use the pool. Legal cases resulting from negligence include judgements against the owner due to: lack of lifeguard training, inattentiveness on the part of lifeguards, improper depth markings, water containing infectious organisms, and…

  1. Focus on Preschool Aquatics: Child Care Regulations.

    ERIC Educational Resources Information Center

    Sayre, Nancy E.

    This paper proposes state regulations for the training of child care staff members in developmentally appropriate safe aquatic practices, outlines required features of any pools that children visit, and suggests safe practices for water-related activities at child care centers and swimming pools. The staff training regulation suggestions include…

  2. Vortices revealed: Swimming faster

    NASA Astrophysics Data System (ADS)

    van Houwelingen, Josje; van de Water, Willem; Kunnen, Rudie; van Heijst, Gertjan; Clercx, Herman

    2016-11-01

    Understanding and optimizing the propulsion in human swimming requires insight into the hydrodynamics of the flow around the swimmer. Experiments and simulations addressing the hydrodynamics of swimming have been conducted in studies before, including the visualization of the flow using particle image velocimetry (PIV). The main objective in this study is to develop a system to visualize the flow around a swimmer in practice inspired by this technique. The setup is placed in a regular swimming pool. The use of tracer particles and lasers to illuminate the particles is not allowed. Therefore, we choose to work with air bubbles with a diameter of 4 mm, illuminated by ambient light. Homogeneous bubble curtains are produced by tubes implemented in the bottom of the pool. The bubble motion is captured by six cameras placed in underwater casings. A first test with the setup has been conducted by pulling a cylinder through the bubbles and performing a PIV analysis. The vorticity plots of the resulting data show the expected vortex street behind the cylinder. The shedding frequency of the vortices resembles the expected frequency. Thus, it is possible to identify and follow the coherent structures. We will discuss these results and the first flow measurements around swimmers.

  3. Violations identified from routine swimming pool inspections--selected states and counties, United States, 2008.

    PubMed

    2010-05-21

    Swimming is the third most popular U.S. sport or exercise activity, with approximately 314 million visits to recreational water venues, including treated venues (e.g., pools), each year. The most frequently reported type of recreational water illness (RWI) outbreak is gastroenteritis, the incidence of which is increasing. During 1997--2006, chlorine- and bromine-susceptible pathogens (e.g., Shigella and norovirus) caused 24 (23%) of 104 treated venue--associated RWI outbreaks of gastroenteritis, indicating lapses in proper operation of pools. Pool inspectors help minimize the risk for RWIs and injuries by enforcing regulations that govern public treated recreational water venues. To assess pool code compliance, CDC analyzed 2008 data from 121,020 routine pool inspections conducted by a convenience sample of 15 state and local agencies. Because pool codes and, therefore, inspection items differed across jurisdictions, reported denominators varied. Of 111,487 inspections, 13,532 (12.1%) resulted in immediate closure because of serious violations (e.g., lack of disinfectant in the water). Of 120,975 inspections, 12,917 (10.7%) identified disinfectant level violations. Although these results likely are not representative of all pools in the United States, they suggest the need for increased public health scrutiny and improved pool operation. The results also demonstrate that pool inspection data can be used as a potential source for surveillance to guide resource allocation and regulatory decision-making. Collecting pool inspection data in a standardized, electronic format can facilitate routine analysis to support efforts to reduce health and safety risks for swimmers.

  4. Inappropriate Implantable Cardioverter-Defibrillator Shocks Attributed to Alternating-Current Leak in a Swimming Pool

    PubMed Central

    Makaryus, John N.; Angert-Gilman, Julia; Yacoub, Mena; Patel, Apoor

    2014-01-01

    Implantable cardioverter-defibrillators (ICDs) are the standard of care for preventing sudden cardiac death in patients who are predisposed to malignant ventricular arrhythmias. Causes of inappropriate ICD shock include equipment malfunction, improper arrhythmia evaluation, misinterpretation of myopotentials, and electromagnetic interference. As the number of implanted ICDs has increased, other contributors to inappropriate therapy have become known, such as minimal electrical current leaks that mimic ventricular fibrillation. We present the case of a 63-year-old man with a biventricular ICD who received 2 inappropriate shocks, probably attributable to alternating-current leaks in a swimming pool. In addition, we discuss ICD sensitivity and offer recommendations to avoid similar occurrences. PMID:24512403

  5. STS-45 backup Payload Specialist Chappell during water egress training at JSC

    NASA Technical Reports Server (NTRS)

    1991-01-01

    STS-45 Atlantis, Orbiter Vehicle (OV) 104, backup Payload Specialist Charles R. Chappell, wearing launch and entry suit (LES), is suspended via his parachute harness above JSC's Weightless Environment Training Facility (WETF) Bldg 29 pool. Chappell will be dropped into the pool during the exercise which simulates a parachute landing into a body of water. SCUBA-equipped divers swimming in the pool will assist during the training.

  6. Effects of UV 254 irradiation on residual chlorine and DBPs in chlorination of model organic-N precursors in swimming pools.

    PubMed

    Weng, ShihChi; Li, Jing; Blatchley, Ernest R

    2012-05-15

    Ultraviolet (UV) irradiation is commonly applied as a secondary disinfection process in chlorinated pools. UV-based systems have been reported to yield improvements in swimming pool water and air chemistry, but to date these observations have been largely anecdotal. The objectives of this investigation were to evaluate the effects of UV irradiation on chlorination of important organic-N precursors in swimming pools. Creatinine, L-arginine, L-histidine, glycine, and urea, which comprise the majority of the organic-N in human sweat and urine, were selected as precursors for use in conducting batch experiments to examine the time-course behavior of several DBPs and residual chlorine, with and without UV(254) irradiation. In addition, water samples from two natatoria were subjected to monochromatic UV irradiation at wavelengths of 222 nm and 254 nm to evaluate changes of liquid-phase chemistry. UV(254) irradiation promoted formation and/or decay of several chlorinated N-DBPs and also increased the rate of free chlorine consumption. UV exposure resulted in loss of inorganic chloramines (e.g., NCl(3)) from solution. Dichloromethylamine (CH(3)NCl(2)) formation from creatinine was promoted by UV exposure, when free chlorine was present in solution; however, when free chlorine was depleted, CH(3)NCl(2) photodecay was observed. Dichloroacetonitrile (CNCHCl(2)) formation (from L-histidine and L-arginine) was promoted by UV(254) irradiation, as long as free chlorine was present in solution. Likewise, UV exposure was observed to amplify cyanogen chloride (CNCl) formation from chlorination of L-histidine, L-arginine, and glycine, up to the point of free chlorine depletion. The results from experiments involving UV irradiation of chlorinated swimming pool water were qualitatively consistent with the results of model experiments involving UV/chlorination of precursors in terms of the behavior of residual chlorine and DBPs measured in this study. The results indicate that UV(254) irradiation promotes several reactions that are involved in the formation and/or destruction of chlorinated N-DBPs in pool settings. Enhancement of DBP formation was consistent with a mechanism whereby a rate-limiting step in DBP formation was promoted by UV exposure. Promotion of these reactions also resulted in increases of free chlorine consumption rates. Copyright © 2012 Elsevier Ltd. All rights reserved.

  7. Associations between Moderate-to-Vigorous Physical Activity and Neighbourhood Recreational Facilities: The Features of the Facilities Matter

    PubMed Central

    Lee, Ka Yiu; Lee, Paul H.; Macfarlane, Duncan

    2014-01-01

    Objectives: To examine the associations between objectively-assessed moderate-to-vigorous physical activity (MVPA) and perceived/objective measures of neighbourhood recreational facilities categorized into indoor or outdoor, public, residential or commercial facilities. The associations between facility perceptions and objectively-assessed numbers of recreational facilities were also examined. Method: A questionnaire was used on 480 adults to measure local facility perceptions, with 154 participants wearing ActiGraph accelerometers for ≥4 days. The objectively-assessed number of neighbourhood recreational facilities were examined using direct observations and Geographical Information System data. Results: Both positive and negative associations were found between MVPA and perceived/objective measures of recreational facilities. Some associations depended on whether the recreational facilities were indoor or outdoor, public or residential facilities. The objectively-assessed number of most public recreational facilities was associated with the corresponding facility perceptions, but the size of effect was generally lower than for residential recreational facilities. Conclusions: The objectively-assessed number of residential outdoor table tennis courts and public indoor swimming pools, the objectively-assessed presence of tennis courts and swimming pools, and the perceived presence of bike lanes and swimming pools were positive determinants of MVPA. It is suggested to categorize the recreational facilities into smaller divisions in order to identify unique associations with MVPA. PMID:25485980

  8. The validity of virtual environments for eliciting emotional responses in patients with eating disorders and in controls.

    PubMed

    Ferrer-García, Marta; Gutiérrez-Maldonado, José; Caqueo-Urízar, Alejandra; Moreno, Elena

    2009-11-01

    This article explores the efficacy of virtual environments representing situations that are emotionally significant to patients with eating disorders (ED) to modify depression and anxiety levels both in these patients and in controls. Eighty-five ED patients and 108 students were randomly exposed to five experimental virtual environments (a kitchen with low-calorie food, a kitchen with high-calorie food, a restaurant with high-calorie food, a restaurant with low-calorie food, and a swimming-pool) and to one neutral environment. In the interval between the presentation of each situation, anxiety and depressed mood were assessed. Results of several repeated measures analyses demonstrated that patients show higher levels of anxiety and a more depressed mood after eating, especially high-calorie food, and after visiting the swimming pool than in the neutral room. In contrast, controls only show higher levels of anxiety in the swimming pool. In the rest of the situations they presented a similar mood state as in the neutral room. We concluded that virtual reality is a useful vehicle for eliciting similar emotional reactions to those one would expect in real life situations. Thus, this technology seems well suited for use in experimental studies as well as in evaluative and therapeutic contexts.

  9. Incremental exercise test for the evaluation of peak oxygen consumption in paralympic swimmers.

    PubMed

    de Souza, Helton; DA Silva Alves, Eduardo; Ortega, Luciana; Silva, Andressa; Esteves, Andrea M; Schwingel, Paulo A; Vital, Roberto; DA Rocha, Edilson A; Rodrigues, Bruno; Lira, Fabio S; Tufik, Sergio; DE Mello, Marco T

    2016-04-01

    Peak oxygen consumption (VO2peak) is a fundamental parameter used to evaluate physical capacity. The objective of this study was to explore two types of incremental exercise tests used to determine VO2peak in four Paralympic swimmers: arm ergometer testing in the laboratory and testing in the swimming pool. On two different days, the VO2peak values of the four athletes were measured in a swimming pool and by a cycle ergometer. The protocols identified the VO2peak by progressive loading until the volitional exhaustion maximum was reached. The results were analyzed using the paired Student's t-test, Cohen's d effect sizes and a linear regression. The results showed that the VO2peak values obtained using the swimming pool protocol were higher (P=0.02) than those obtained by the arm ergometer (45.8±19.2 vs. 30.4±15.5; P=0.02), with a large effect size (d=3.20). When analyzing swimmers 1, 2, 3 and 4 individually, differences of 22.4%, 33.8%, 60.1% and 27.1% were observed, respectively. Field tests similar to the competitive setting are a more accurate way to determine the aerobic capacity of Paralympic swimmers. This approach provides more sensitive data that enable better direction of training, consequently facilitating improved performance.

  10. The validation of a swimming turn wall-contact-time measurement system: a touchpad application reliability study.

    PubMed

    Brackley, Victoria; Ball, Kevin; Tor, Elaine

    2018-05-12

    The effectiveness of the swimming turn is highly influential to overall performance in competitive swimming. The push-off or wall contact, within the turn phase, is directly involved in determining the speed the swimmer leaves the wall. Therefore, it is paramount to develop reliable methods to measure the wall-contact-time during the turn phase for training and research purposes. The aim of this study was to determine the concurrent validity and reliability of the Pool Pad App to measure wall-contact-time during the freestyle and backstroke tumble turn. The wall-contact-times of nine elite and sub-elite participants were recorded during their regular training sessions. Concurrent validity statistics included the standardised typical error estimate, linear analysis and effect sizes while the intraclass correlating coefficient (ICC) was used for the reliability statistics. The standardised typical error estimate resulted in a moderate Cohen's d effect size with an R 2 value of 0.80 and the ICC between the Pool Pad and 2D video footage was 0.89. Despite these measurement differences, the results from this concurrent validity and reliability analyses demonstrated that the Pool Pad is suitable for measuring wall-contact-time during the freestyle and backstroke tumble turn within a training environment.

  11. Bacterial populations on silicone hydrogel and hydrogel contact lenses after swimming in a chlorinated pool.

    PubMed

    Choo, Jennifer; Vuu, Kathy; Bergenske, Peter; Burnham, Kara; Smythe, Jennifer; Caroline, Patrick

    2005-02-01

    A number of reports have indicated an association between swimming with contact lenses and subsequent eye infection. This study tests whether a hydrophilic contact lens worn while swimming accumulates bacteria present in the water. It was of interest to determine whether lens type (silicone hydrogel vs. hydrogel) affected the result. Fifteen healthy noncontact lens wearers swam for 30 minutes with a silicone hydrogel lens (PureVision, Bausch & Lomb, Rochester, NY) on one eye and a hydrogel lens (Acuvue 2, Vistakon Inc., Jacksonville, FL) on the other. Lenses were removed aseptically and placed in sterile vials 10 minutes after the subjects left the water. Microbial growth was enumerated for total numbers of colonies and categorized by species present. Numbers of colonies were compared between the two lens groups and with a water sample taken from the pool at the time of the experiment. Eight of the subjects returned on a different day and wore new lenses for 50 minutes in normal room conditions. Two lenses were lost while swimming. Twenty-seven of the remaining 28 lenses worn while swimming showed colonization, principally with Staphylococcus epidermidis, which was also by far the most common species identified from the water itself. Small numbers of Staphylococcus aureus and Streptococcus salivarius were also present in the water and on the lenses. Numbers of colonies varied among subjects (range, 0 to 230), but no differences were observed between the two lens groups. Lenses removed after 30 minutes of wear without swimming were mostly sterile, with 3 of 16 lenses showing just two colonies each. It appears that wearing a hydrophilic lens while swimming allows accumulation of microbial organisms on or in the lens, regardless of lens material. Swimmers should be advised to wear tight-fitting goggles if lenses are worn while swimming, and thorough disinfection of the lenses before overnight wear seems prudent.

  12. Fitness and Independence after SCI: Defining Meaningful Change and Thresholds

    DTIC Science & Technology

    2015-10-01

    a sporting activity Yes (professional, recreational, or leisure) when you No were injured? (For example, swimming, diving, horseback riding, biking...etc.) Please select the sporting activity Diving (into pool, ocean, lake, etc) Swimming Surfing Motocross/dirt bike riding Cycling Gymnastics...Equestrian sports (riding or racing) Other Other __________________________________ Did your injury occur as the result of an assault, Yes attack, or act of

  13. Disposable swim diaper retention of Cryptosporidium-sized particles on human subjects in a recreational water setting.

    PubMed

    Amburgey, James E; Anderson, J Brian

    2011-12-01

    Cryptosporidium is a chlorine-resistant protozoan parasite responsible for the majority of waterborne disease outbreaks in recreational water venues in the USA. Swim diapers are commonly used by diaper-aged children participating in aquatic activities. This research was intended to evaluate disposable swim diapers for retaining 5-μm diameter polystyrene microspheres, which were used as non-infectious surrogates for Cryptosporidium oocysts. A hot tub recirculating water without a filter was used for this research. The microsphere concentration in the water was monitored at regular intervals following introduction of microspheres inside of a swim diaper while a human subject undertook normal swim/play activities. Microsphere concentrations in the bulk water showed that the majority (50-97%) of Cryptosporidium-sized particles were released from the swim diaper within 1 to 5 min regardless of the swim diaper type or configuration. After only 10 min of play, 77-100% of the microspheres had been released from all swim diapers tested. This research suggests that the swim diapers commonly used by diaper-aged children in swimming pools and other aquatic activities are of limited value in retaining Cryptosporidium-sized particles. Improved swim diaper solutions are necessary to efficiently retain pathogens and effectively safeguard public health in recreational water venues.

  14. Prevalence and antibiotic resistance of Pseudomonas aeruginosa in water samples in central Italy and molecular characterization of oprD in imipenem resistant isolates

    PubMed Central

    Carloni, Elisa; Andreoni, Francesca; Magi, Silvia; Chironna, Maria; Brandi, Giorgio; Amagliani, Giulia

    2017-01-01

    Scope This study aimed to analyse the prevalence, antibiotic resistance and genetic relatedness of P. aeruginosa isolates obtained from potable and recreational water samples (n. 8,351) collected from different settings (swimming pools, n. 207; healthcare facilities, n 1,684; accommodation facilities, n. 1,518; municipal waterworks, n. 4,500; residential buildings, n. 235). Possible mechanisms underlying resistance to imipenem, with particular focus on those involving oprD-based uptake, were also explored. Methods and results Isolation and identification of Pseudomonas aeruginosa was performed according to the standardized procedure UNI EN ISO 16266:2008 followed by PCR confirmation. Antibiotic Susceptibility testing was conducted according to EUCAST standardized disk diffusion method. Genetic relatedness of strains was carried out by RAPD. The sequence of the oprD gene was analyzed by standard method. Fifty-three samples (0.63%) were positive for P. aeruginosa, of which 10/207 (4.83%) were from swimming pools. Five isolates (9.43%) were resistant to imipenem, one to Ticarcillin + Clavulanate, one to both Piperacillin and Ticarcillin + Clavulanate. The highest isolation rate of imipenem resistant P. aeruginosa was observed in swimming pool water. Identical RAPD profiles were found in isolates from the same location in the same year or even in different years. Conclusions Imipenem resistant strains were identified as carbapenemase-negative and resistance has been associated with inactivating mutations within the oprD gene, with a concomitant loss of porin. RAPD results proved that a water system can remain colonized by one strain for long periods and the contamination may be difficult to eradicate. This study has revealed the presence of P. aeruginosa in different water samples, including resistant strains, especially in swimming pools, and confirmed the role of porins as a contributing factor in carbapenem resistance in Gram-negative bacteria. PMID:29211780

  15. Prevalence and antibiotic resistance of Pseudomonas aeruginosa in water samples in central Italy and molecular characterization of oprD in imipenem resistant isolates.

    PubMed

    Schiavano, Giuditta Fiorella; Carloni, Elisa; Andreoni, Francesca; Magi, Silvia; Chironna, Maria; Brandi, Giorgio; Amagliani, Giulia

    2017-01-01

    This study aimed to analyse the prevalence, antibiotic resistance and genetic relatedness of P. aeruginosa isolates obtained from potable and recreational water samples (n. 8,351) collected from different settings (swimming pools, n. 207; healthcare facilities, n 1,684; accommodation facilities, n. 1,518; municipal waterworks, n. 4,500; residential buildings, n. 235). Possible mechanisms underlying resistance to imipenem, with particular focus on those involving oprD-based uptake, were also explored. Isolation and identification of Pseudomonas aeruginosa was performed according to the standardized procedure UNI EN ISO 16266:2008 followed by PCR confirmation. Antibiotic Susceptibility testing was conducted according to EUCAST standardized disk diffusion method. Genetic relatedness of strains was carried out by RAPD. The sequence of the oprD gene was analyzed by standard method. Fifty-three samples (0.63%) were positive for P. aeruginosa, of which 10/207 (4.83%) were from swimming pools. Five isolates (9.43%) were resistant to imipenem, one to Ticarcillin + Clavulanate, one to both Piperacillin and Ticarcillin + Clavulanate. The highest isolation rate of imipenem resistant P. aeruginosa was observed in swimming pool water. Identical RAPD profiles were found in isolates from the same location in the same year or even in different years. Imipenem resistant strains were identified as carbapenemase-negative and resistance has been associated with inactivating mutations within the oprD gene, with a concomitant loss of porin. RAPD results proved that a water system can remain colonized by one strain for long periods and the contamination may be difficult to eradicate. This study has revealed the presence of P. aeruginosa in different water samples, including resistant strains, especially in swimming pools, and confirmed the role of porins as a contributing factor in carbapenem resistance in Gram-negative bacteria.

  16. Use of In Vitro Assays to Assess the Contribution of Environmental Contaminants on Water Mutagenicity

    EPA Science Inventory

    Although the formation and associated health effects of disinfection by-products (DBPs) in drinking water have been studied for nearly 40 years, similar research on swimming pool and hot tub (spa) water has begun only recently. Unique to pool and spa waters is the role of human ...

  17. Progressive Increase in Disinfection Byproducts and Mutagenicity from Sourceto Tap to Swimming Pool and Spa Water: Implications for Public Health

    EPA Science Inventory

    Pools and spas are enjoyed throughout the world for exercise and relaxation. However, there are no previous studies on the mutagenicity of disinfected spa (hot tub) waters or comprehensive identification of disinfection byproducts (DBPs) formed in spas. Using 28 water samples f...

  18. Progressive Increase in Disinfection By-products and Mutagenicity from Source to Tap to Swimming Pool and Spa Water: Impact of Human Use

    EPA Science Inventory

    Pools and spas are enjoyed throughout the world for exercise and relaxation. However, there are no previous studies on mutagenicity of disinfected spa (hot tub) waters or comprehensive identification of disinfection byproducts (DBPs) formed in spas. Using 28 water samples from ...

  19. Pool Rules: A Survival Guide for Parents and Children

    ERIC Educational Resources Information Center

    Grosse, Susan J.

    2008-01-01

    In most sports and physical activities rules are present to facilitate participation, outlining courtesy during play as well as establishing guidelines for keeping any competition fair. In contrast, rules for appropriate behavior in swimming pools serve a much more important purpose--that of ensuring health and safety for all participants.…

  20. Chlorinated Chromosomes: The Impact of Human Use on the Levels of Disinfection By-products and Mutagenicity of Swimming Pools and Hot Tubs

    EPA Science Inventory

    Pools and spas are enjoyed throughout the world for exercise and relaxation. However, there are no previous studies on mutagenicity of disinfected spa (hot tub) waters or comprehensive identification of disinfection byproducts (DBPs) formed in spas. Using 28 water samples from ...

  1. Fuel transfer system

    DOEpatents

    Townsend, Harold E.; Barbanti, Giancarlo

    1994-01-01

    A nuclear fuel bundle fuel transfer system includes a transfer pool containing water at a level above a reactor core. A fuel transfer machine therein includes a carriage disposed in the transfer pool and under the water for transporting fuel bundles. The carriage is selectively movable through the water in the transfer pool and individual fuel bundles are carried vertically in the carriage. In a preferred embodiment, a first movable bridge is disposed over an upper pool containing the reactor core, and a second movable bridge is disposed over a fuel storage pool, with the transfer pool being disposed therebetween. A fuel bundle may be moved by the first bridge from the reactor core and loaded into the carriage which transports the fuel bundle to the second bridge which picks up the fuel bundle and carries it to the fuel storage pool.

  2. Fuel transfer system

    DOEpatents

    Townsend, H.E.; Barbanti, G.

    1994-03-01

    A nuclear fuel bundle fuel transfer system includes a transfer pool containing water at a level above a reactor core. A fuel transfer machine therein includes a carriage disposed in the transfer pool and under the water for transporting fuel bundles. The carriage is selectively movable through the water in the transfer pool and individual fuel bundles are carried vertically in the carriage. In a preferred embodiment, a first movable bridge is disposed over an upper pool containing the reactor core, and a second movable bridge is disposed over a fuel storage pool, with the transfer pool being disposed therebetween. A fuel bundle may be moved by the first bridge from the reactor core and loaded into the carriage which transports the fuel bundle to the second bridge which picks up the fuel bundle and carries it to the fuel storage pool. 6 figures.

  3. IEA-R1 Nuclear Research Reactor: 58 Years of Operating Experience and Utilization for Research, Teaching and Radioisotopes Production

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cardenas, Jose Patricio Nahuel; Filho, Tufic Madi; Saxena, Rajendra

    IEA-R1 research reactor at the Instituto de Pesquisas Energeticas e Nucleares (Nuclear and Energy Research Institute) IPEN, Sao Paulo, Brazil is the largest power research reactor in Brazil, with a maximum power rating of 5 MWth. It is being used for basic and applied research in the nuclear and neutron related sciences, for the production of radioisotopes for medical and industrial applications, and for providing services of neutron activation analysis, real time neutron radiography, and neutron transmutation doping of silicon. IEA-R1 is a swimming pool reactor, with light water as the coolant and moderator, and graphite and beryllium as reflectors.more » The reactor was commissioned on September 16, 1957 and achieved its first criticality. It is currently operating at 4.5 MWth with a 60-hour cycle per week. In the early sixties, IPEN produced {sup 131}I, {sup 32}P, {sup 198}Au, {sup 24}Na, {sup 35}S, {sup 51}Cr and labeled compounds for medical use. During the past several years, a concerted effort has been made in order to upgrade the reactor power to 5 MWth through refurbishment and modernization programs. One of the reasons for this decision was to produce {sup 99}Mo at IPEN. The reactor cycle will be gradually increased to 120 hours per week continuous operation. It is anticipated that these programs will assure the safe and sustainable operation of the IEA-R1 reactor for several more years, to produce important primary radioisotopes {sup 99}Mo, {sup 125}I, {sup 131}I, {sup 153}Sm and {sup 192}Ir. Currently, all aspects of dealing with fuel element fabrication, fuel transportation, isotope processing, and spent fuel storage are handled by IPEN at the site. The reactor modernization program is slated for completion by 2015. This paper describes 58 years of operating experience and utilization of the IEA-R1 research reactor for research, teaching and radioisotopes production. (authors)« less

  4. The international atom: evolution of radiation control programs.

    PubMed

    Bradley, F J

    2002-07-01

    Under the Atoms for Peace program, Turkey received a one MWt swimming pool reactor in 1962 that initiated a health physics program for the reactor and a Radiation Control Program (RCP) for the country's use of ionizing radiation. Today, over 13,000 radiation workers, concentrated in the medical field, provide improved medical care with 6,200 x-ray units, including 494 CAT scanners, 222 radioimmunoassay (RIA) labs and 42 radiotherapy centers. Industry has a large stake in the safe use of ionizing radiation with over 1,200 x-ray and gamma radiography and fluoroscopic units, 2,500 gauges in automated process control and five irradiators. A 48-person RCP staff oversees this expanded radiation use. One incident involving a spent 3.3 TBq (88 Ci) 60Co source resulted in 10 overexposures but no fatalities. Taiwan received a 1.6 MWt swimming pool reactor in 1961 and rapidly applied nuclear technology to the medical and industrial fields. Today, there are approximately 24,000 licensed radiation workers in nuclear power field, industry, medicine and academia. Four BWRs and two PWRs supply about 25% of the island's electrical power needs. One traumatic event galvanized the RCP when an undetermined amount of 60Co was accidentally incorporated into reinforcing bars, which in turn were incorporated into residential and commercial buildings. Public exposures were estimated to range up to 15 mSv (1.3 rem) per annum. There were no reported ill effects, except possibly psychological, to date. The RCP now has instituted stringent control measures to ensure radiation-free dwellings and work places. Albania's RCP is described as it evolved since 1972. Regulations were promulgated which followed the IAEA Basic Safety Standards of that era. With 525 licenses and 600 radiation workers, the problem was not in the regulations per se but in their enforcement. The IAEA helped to upgrade the RCP as the economy evolved from one that was centrally planned economy to a free market economy. As this transition takes place, public radiation exposures in the medical field will continue to be high until the old x-ray equipment is phased out. A small conscientious health physics staff works with limited resources to keep radiation exposures at acceptable levels. These three country RCPs, as they have evolved, have some commonality. Today, all radiation installations are licensed, both for radioactive material and x-ray equipment. Radiation workers are individually licensed or registered. All RCPs have, or are striving to have, their radiation regulations conform to ICRP 60 recommendations as spelled out in the Basic Safety Standard (1996). Finally, all three countries have as yet to find a permanent solution for their radioactive waste.

  5. Naegleria

    MedlinePlus

    ... of warm freshwater, such as lakes and rivers Geothermal (naturally hot) water, such as hot springs Warm water discharge from industrial plants Geothermal (naturally hot) drinking water sources Swimming pools that ...

  6. Fast determination of octinoxate and oxybenzone uv filters in swimming pool waters by gas chromatography/mass spectrometry after solid-phase microextraction.

    PubMed

    Yılmazcan, Ö; Kanakaki, C; Izgi, B; Rosenberg, E

    2015-07-01

    A fast gas chromatography/mass spectrometry method was developed and validated for the analysis of the potential endocrine disrupters octinoxate and oxybenzone in swimming pool water samples based on the solvent-free solid-phase microextraction technique. The low-pressure gas chromatography/mass spectrometry method used for the fast identification of UV filter substances was compared to a conventional method in terms of sensitivity and speed. The fast method proposed resulted in 2 min runs, leading to an eightfold decrease in the total analysis time and a sevenfold improvement in detection limits. The main parameters affecting the solid-phase microextraction process were also studied in detail and the optimized conditions were as follows: fiber coating, polyacrylate; extraction mode, direct immersion; extraction temperature, 25°C; sample volume, 5 mL; extraction time 45 min; pH 6.5. Under the optimized conditions, a linear response was obtained in the concentration range of 0.5-25 μg/L with correlation coefficients in the range 0.990-0.999. The limits of detection were 0.17-0.29 μg/L, and the recoveries were 80-83%. Combined method uncertainty was assessed and found to be less than 7% for both analytes for concentrations equal to or higher than 5 μg/L. Pool water samples were analyzed to demonstrate the applicability of the proposed method. Neither octinoxate nor oxybenzone were detected in the swimming pool water samples at concentrations above the respective limits of detection. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Uncle Tim's Dilemma

    ERIC Educational Resources Information Center

    DiBiase, Warren

    2009-01-01

    In this investigation, students make predictions and observations of a counterintuitive phenomenon. Given the scenario of a boat filled with a set of large rocks placed in a swimming pool, the students investigate what happens to both the water level in the pool and the level at which the boat floats when the rocks are taken out of the boat and…

  8. Fuel handling system for a nuclear reactor

    DOEpatents

    Saiveau, James G.; Kann, William J.; Burelbach, James P.

    1986-01-01

    A pool type nuclear fission reactor has a core, with a plurality of core elements and a redan which confines coolant as a hot pool at a first end of the core separated from a cold pool at a second end of the core by the redan. A fuel handling system for use with such reactors comprises a core element storage basket located outside of the redan in the cold pool. An access passage is formed in the redan with a gate for opening and closing the passage to maintain the temperature differential between the hot pool and the cold pool. A mechanism is provided for opening and closing the gate. A lifting arm is also provided for manipulating the fuel core elements through the access passage between the storage basket and the core when the redan gate is open.

  9. Fuel handling system for a nuclear reactor

    DOEpatents

    Saiveau, James G.; Kann, William J.; Burelbach, James P.

    1986-12-02

    A pool type nuclear fission reactor has a core, with a plurality of core elements and a redan which confines coolant as a hot pool at a first end of the core separated from a cold pool at a second end of the core by the redan. A fuel handling system for use with such reactors comprises a core element storage basket located outside of the redan in the cold pool. An access passage is formed in the redan with a gate for opening and closing the passage to maintain the temperature differential between the hot pool and the cold pool. A mechanism is provided for opening and closing the gate. A lifting arm is also provided for manipulating the fuel core elements through the access passage between the storage basket and the core when the redan gate is open.

  10. Exercise-training intervention studies in competitive swimming.

    PubMed

    Aspenes, Stian Thoresen; Karlsen, Trine

    2012-06-01

    Competitive swimming has a long history and is currently one of the largest Olympic sports, with 16 pool events. Several aspects separate swimming from most other sports such as (i) the prone position; (ii) simultaneous use of arms and legs for propulsion; (iii) water immersion (i.e. hydrostatic pressure on thorax and controlled respiration); (iv) propulsive forces that are applied against a fluctuant element; and (v) minimal influence of equipment on performance. Competitive swimmers are suggested to have specific anthropometrical features compared with other athletes, but are nevertheless dependent on physiological adaptations to enhance their performance. Swimmers thus engage in large volumes of training in the pool and on dry land. Strength training of various forms is widely used, and the energetic systems are addressed by aerobic and anaerobic swimming training. The aim of the current review was to report results from controlled exercise training trials within competitive swimming. From a structured literature search we found 17 controlled intervention studies that covered strength or resistance training, assisted sprint swimming, arms-only training, leg-kick training, respiratory muscle training, training the energy delivery systems and combined interventions across the aforementioned categories. Nine of the included studies were randomized controlled trials. Among the included studies we found indications that heavy strength training on dry land (one to five repetitions maximum with pull-downs for three sets with maximal effort in the concentric phase) or sprint swimming with resistance towards propulsion (maximal pushing with the arms against fixed points or pulling a perforated bowl) may be efficient for enhanced performance, and may also possibly have positive effects on stroke mechanics. The largest effect size (ES) on swimming performance was found in 50 m freestyle after a dry-land strength training regimen of maximum six repetitions across three sets in relevant muscle-groups (ES 1.05), and after a regimen of resisted- and assisted-sprint training with elastic surgical tubes (ES 1.21). Secondly, several studies suggest that high training volumes do not pose any immediate advantage over lower volumes (with higher intensity) for swim performance. Overall, very few studies were eligible for the current review although the search strategy was broad and fairly liberal. The included studies predominantly involved freestyle swimming and, overall, there seems to be more questions than answers within intervention-based competitive swimming research. We believe that this review may encourage other researchers to pursue the interesting topics within the physiology of competitive swimming.

  11. Passive shut-down heat removal system

    DOEpatents

    Hundal, Rolv; Sharbaugh, John E.

    1988-01-01

    An improved shut-down heat removal system for a liquid metal nuclear reactor of the type having a vessel for holding hot and cold pools of liquid sodium is disclosed herein. Generally, the improved system comprises a redan or barrier within the reactor vessel which allows an auxiliary heat exchanger to become immersed in liquid sodium from the hot pool whenever the reactor pump fails to generate a metal-circulating pressure differential between the hot and cold pools of sodium. This redan also defines an alternative circulation path between the hot and cold pools of sodium in order to equilibrate the distribution of the decay heat from the reactor core. The invention may take the form of a redan or barrier that circumscribes the inner wall of the reactor vessel, thereby defining an annular space therebetween. In this embodiment, the bottom of the annular space communicates with the cold pool of sodium, and the auxiliary heat exchanger is placed in this annular space just above the drawn-down level that the liquid sodium assumes during normal operating conditions. Alternatively, the redan of the invention may include a pair of vertically oriented, concentrically disposed standpipes having a piston member disposed between them that operates somewhat like a pressure-sensitive valve. In both embodiments, the cessation of the pressure differential that is normally created by the reactor pump causes the auxiliary heat exchanger to be immersed in liquid sodium from the hot pool. Additionally, the redan in both embodiments forms a circulation flow path between the hot and cold pools so that the decay heat from the nuclear core is uniformly distributed within the vessel.

  12. Reactor core isolation cooling system

    DOEpatents

    Cooke, F.E.

    1992-12-08

    A reactor core isolation cooling system includes a reactor pressure vessel containing a reactor core, a drywell vessel, a containment vessel, and an isolation pool containing an isolation condenser. A turbine is operatively joined to the pressure vessel outlet steamline and powers a pump operatively joined to the pressure vessel feedwater line. In operation, steam from the pressure vessel powers the turbine which in turn powers the pump to pump makeup water from a pool to the feedwater line into the pressure vessel for maintaining water level over the reactor core. Steam discharged from the turbine is channeled to the isolation condenser and is condensed therein. The resulting heat is discharged into the isolation pool and vented to the atmosphere outside the containment vessel for removing heat therefrom. 1 figure.

  13. Reactor core isolation cooling system

    DOEpatents

    Cooke, Franklin E.

    1992-01-01

    A reactor core isolation cooling system includes a reactor pressure vessel containing a reactor core, a drywell vessel, a containment vessel, and an isolation pool containing an isolation condenser. A turbine is operatively joined to the pressure vessel outlet steamline and powers a pump operatively joined to the pressure vessel feedwater line. In operation, steam from the pressure vessel powers the turbine which in turn powers the pump to pump makeup water from a pool to the feedwater line into the pressure vessel for maintaining water level over the reactor core. Steam discharged from the turbine is channeled to the isolation condenser and is condensed therein. The resulting heat is discharged into the isolation pool and vented to the atmosphere outside the containment vessel for removing heat therefrom.

  14. Do swimming goggles limit microbial contamination of contact lenses?

    PubMed

    Wu, Yvonne T; Tran, Jess; Truong, Michelle; Harmis, Najat; Zhu, Hua; Stapleton, Fiona

    2011-04-01

    Wearing goggles over contact lenses while swimming is often recommended by eye care professionals. Limited data are available to assess this recommendation. The purpose of this study was to examine whether wearing goggles while swimming limits bacterial colonization on contact lenses and whether the type of lens worn affects contamination rates. Twenty-three subjects underwent two swimming sessions at an ocean (salt water) pool (Maroubra beach Rock Pool, Sydney, Australia). Silicone hydrogel (Ciba Focus Night and Day) or hydrogel lenses (Ciba Focus Daily) were inserted into subjects' eyes before 30 min of swimming sessions, and subjects used modified goggles to mimic goggled and non-goggled conditions. At the end of each session, lenses were collected for microbial investigation. Viable bacterial colonies were classified as gram positive and gram negative and enumerated. The level of bacterial colonization on contact lenses between goggled and non-goggled conditions and between the two lens materials were compared. The range of colony forming units recovered from goggled lenses were 0 to 930 compared with 0 to 1210 on non-goggled lenses. The majority of subjects (16/23) had more microorganisms in the non-goggled condition than when wearing goggles (p = 0.03). Gram negative organisms were found in three non-goggled lenses. No significant difference was shown in the number of bacteria isolated from silicone hydrogel and hydrogel lenses (p > 0.6) irrespective of wearing goggles. Water samples had consistently higher numbers of bacterial counts than those adhered to the lenses; however, no association was found between the number of bacteria in the water sample and those found on the contact lenses. Consistently, fewer bacterial colonies were found on the goggled contact lens, thus suggesting goggles offer some protection against bacterial colonization of contact lenses while swimming. These data would support the recommendation encouraging lens wearers to use goggles while swimming.

  15. Lesions of the hippocampus or dorsolateral striatum disrupt distinct aspects of spatial navigation strategies based on proximal and distal information in a cued variant of the Morris water task

    PubMed Central

    Rice, James P.; Wallace, Douglas G.; Hamilton, Derek A.

    2015-01-01

    The hippocampus and dorsolateral striatum are critically involved in spatial navigation based on extra-maze and intra-maze cues, respectively. Previous reports from our laboratory suggest that behavior in the Morris water task may be guided by both cue types, and rats appear to switch from extra-pool to intra-pool cues to guide navigation in a sequential manner within a given trial. In two experiments, rats with hippocampal or dorsolateral striatal lesions were trained and tested in water task paradigms that involved translation and removal of a cued platform within the pool and translations of the pool itself with respect to the extra-pool cue reference frame. In the first experiment, moment-to-moment analyses of swim behavior indicate that hippocampal lesions disrupt initial trajectories based on extra-pool cues at the beginning of the trial, while dorsolateral striatal lesions disrupt subsequent swim trajectories based on the location of the cued platform at the end of the trial. In the second experiment lesions of the hippocampus, but not the dorsolateral striatum, impaired directional responding in situations where the pool was shifted within the extra-pool cue array. These results are important for understanding the cooperative interactions between the hippocampus and dorsolateral striatum in spatial learning and memory, and establish that these brain areas are continuously involved in goal-directed spatial navigation. These results also highlight the importance of the hippocampus in directional responding in addition to place navigation. PMID:25907746

  16. Thermal Stratification Analysis for Sodium Fast Reactors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schneider, James; Anderson, Mark; Baglietto, Emilio

    The sodium fast reactor (SFR) is the most mature reactor concept of all the generation-IV nuclear systems and is a promising reactor design that is currently under development by several organizations. The majority of sodium fast reactor designs utilize a pool type arrangement which incorporates the primary coolant pumps and intermediate heat exchangers within the sodium pool. These components typically protrude into the pool thus reducing the risk and severity of a loss of coolant accidents. To further ensure safe operation under even the most severe transients a more comprehensive understanding of key thermal hydraulic phenomena in this pool ismore » desired. One of the key technology gaps identified for SFR safety is determining the extent and the effects of thermal stratification developing in the pool during postulated accident scenarios such as a protected or unprotected loss of flow incident. In an effort to address these issues, detailed flow models of transient stratification in the pool during an accident can be developed. However, to develop the calculation models, and ensure they can reproduce the underlying physics, highly spatially resolved data is needed. This data can be used in conjunction with advanced computational fluid dynamic calculations to aid in the development of simple reduced dimensional models for systems codes such as SAM and SAS4A/SASSYS-1.« less

  17. Vibro-acoustic Imaging at the Breazeale Reactor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smith, James Arthur; Jewell, James Keith; Lee, James Edwin

    2016-09-01

    The INL is developing Vibro-acoustic imaging technology to characterize microstructure in fuels and materials in spent fuel pools and within reactor vessels. A vibro-acoustic development laboratory has been established at the INL. The progress in developing the vibro-acoustic technology at the INL is the focus of this report. A successful technology demonstration was performed in a working TRIGA research reactor. Vibro-acoustic imaging was performed in the reactor pool of the Breazeale reactor in late September of 2015. A confocal transducer driven at a nominal 3 MHz was used to collect the 60 kHz differential beat frequency induced in a spentmore » TRIGA fuel rod and empty gamma tube located in the main reactor water pool. Data was collected and analyzed with the INLDAS data acquisition software using a short time Fourier transform.« less

  18. Convective cooling in a pool-type research reactor

    NASA Astrophysics Data System (ADS)

    Sipaun, Susan; Usman, Shoaib

    2016-01-01

    A reactor produces heat arising from fission reactions in the nuclear core. In the Missouri University of Science and Technology research reactor (MSTR), this heat is removed by natural convection where the coolant/moderator is demineralised water. Heat energy is transferred from the core into the coolant, and the heated water eventually evaporates from the open pool surface. A secondary cooling system was installed to actively remove excess heat arising from prolonged reactor operations. The nuclear core consists of uranium silicide aluminium dispersion fuel (U3Si2Al) in the form of rectangular plates. Gaps between the plates allow coolant to pass through and carry away heat. A study was carried out to map out heat flow as well as to predict the system's performance via STAR-CCM+ simulation. The core was approximated as porous media with porosity of 0.7027. The reactor is rated 200kW and total heat density is approximately 1.07+E7 Wm-3. An MSTR model consisting of 20% of MSTR's nuclear core in a third of the reactor pool was developed. At 35% pump capacity, the simulation results for the MSTR model showed that water is drawn out of the pool at a rate 1.28 kg s-1 from the 4" pipe, and predicted pool surface temperature not exceeding 30°C.

  19. Analysis of swimming performance from physical, physiological, and biomechanical parameters in young swimmers.

    PubMed

    Jürimäe, Jaak; Haljaste, Kaja; Cicchella, Antonio; Lätt, Evelin; Purge, Priit; Leppik, Aire; Jürimäe, Toivo

    2007-02-01

    The purpose of this study was to examine the influence of the energy cost of swimming, body composition, and technical parameters on swimming performance in young swimmers. Twenty-nine swimmers, 15 prepubertal (11.9 +/- 0.3 years; Tanner Stages 1-2) and 14 pubertal (14.3 +/- 1.4 years; Tanner Stages 3-4) boys participated in the study. The energy cost of swimming (Cs) and stroking parameters were assessed over maximal 400-m front-crawl swimming in a 25-m swimming pool. The backward extrapolation technique was used to evaluate peak oxygen consumption (VO2peak). A stroke index (SI; m2 . s(-1) . cycles(-1)) was calculated by multiplying the swimming speed by the stroke length. VO2peak results were compared with VO2peak test in the laboratory (bicycle, 2.86 +/- 0.74 L/min, vs. in water, 2.53 +/- 0.50 L/min; R2 = .713; p = .0001). Stepwise-regression analyses revealed that SI (R2 = .898), in-water VO2peak (R2 = .358), and arm span (R2 = .454) were the best predictors of swimming performance. The backward-extrapolation method could be used to assess VO2peak in young swimmers. SI, arm span, and VO2peak appear to be the major determinants of front-crawl swimming performance in young swimmers.

  20. [The swimmer's otitis. An up to date and prevention options].

    PubMed

    Caramia, G; Serafini, V; Loggi, A

    2013-01-01

    The swimmer's otitis or acute otitis externa, is a pathology that often occurs in those who practice swimming at a competitive level. The same problem often occurs in the summer with the attendance of swimming pools and bathing areas. A survey made in the United States in 2007 confirms the dynamics of the onset of this pathology, because the contamination of fungi and bacteria in the waters of the swimming pools and the sea cause the inflammation of the epithelium of the auditory canal. To face this issue, in addition to a correct diagnosis, and the necessary and appropriate therapies, it may follow the use of these medicinal preparations. The first one (A) is protective-acting, the second one (B) is characterized as a preventive, hygroscopic, moistening, antiseptic and antimycotic-acting solution. Swimmers who have been using the two (pre-and post) preparations daily for about a year have reported sporadic episodes of otitis. However, there is no doubt that these two compounds deserve a meticulous clinical trial in order to confirm their preventive and therapeutic potentials in external acute otitis.

  1. Athlete's Foot

    MedlinePlus

    ... damp surfaces, such as showers, swimming pools, and locker room floors. To prevent it Keep your feet ... barefoot in public areas Wear flip-flops in locker room showers Keep your toenails clean and clipped ...

  2. Summer Safety

    ERIC Educational Resources Information Center

    Miller, Gayle P.

    1975-01-01

    Offers suggestions for the careful purchase or construction of swimming pools, playground equipment and tents, and for their safe use and maintenance in order to prevent serious injuries or fatalities in young children. (ED)

  3. ENHANCED RETENTION AND SENSITIVITY IN THE ANALYSIS OF CYANURIC ACID IN WATER USING POROUS GRAPHITIC CARBON AND UV DETECTION IN HIGH PRESSURE LIQUID CHROMATOGRAPHY

    EPA Science Inventory

    Cyanuric acid (CA) has found application as a chlorine stabilizer in pool waters. The National Swimming Pool Foundation recommends CA levels between 30-50 ppm and a chlorine residual of 1.0-3.0 ppm. These chlorine levels are needed to destroy harmful pathogenic organisms. Develo...

  4. Nuclear reactor building

    DOEpatents

    Gou, P.F.; Townsend, H.E.; Barbanti, G.

    1994-04-05

    A reactor building for enclosing a nuclear reactor includes a containment vessel having a wetwell disposed therein. The wetwell includes inner and outer walls, a floor, and a roof defining a wetwell pool and a suppression chamber disposed there above. The wetwell and containment vessel define a drywell surrounding the reactor. A plurality of vents are disposed in the wetwell pool in flow communication with the drywell for channeling into the wetwell pool steam released in the drywell from the reactor during a LOCA for example, for condensing the steam. A shell is disposed inside the wetwell and extends into the wetwell pool to define a dry gap devoid of wetwell water and disposed in flow communication with the suppression chamber. In a preferred embodiment, the wetwell roof is in the form of a slab disposed on spaced apart support beams which define there between an auxiliary chamber. The dry gap, and additionally the auxiliary chamber, provide increased volume to the suppression chamber for improving pressure margin. 4 figures.

  5. Nuclear reactor building

    DOEpatents

    Gou, Perng-Fei; Townsend, Harold E.; Barbanti, Giancarlo

    1994-01-01

    A reactor building for enclosing a nuclear reactor includes a containment vessel having a wetwell disposed therein. The wetwell includes inner and outer walls, a floor, and a roof defining a wetwell pool and a suppression chamber disposed thereabove. The wetwell and containment vessel define a drywell surrounding the reactor. A plurality of vents are disposed in the wetwell pool in flow communication with the drywell for channeling into the wetwell pool steam released in the drywell from the reactor during a LOCA for example, for condensing the steam. A shell is disposed inside the wetwell and extends into the wetwell pool to define a dry gap devoid of wetwell water and disposed in flow communication with the suppression chamber. In a preferred embodiment, the wetwell roof is in the form of a slab disposed on spaced apart support beams which define therebetween an auxiliary chamber. The dry gap, and additionally the auxiliary chamber, provide increased volume to the suppression chamber for improving pressure margin.

  6. "Techniques for Teachers" Section

    ERIC Educational Resources Information Center

    Manchester, P.; Ed.

    1976-01-01

    Presents articles on: the measurement of flouride levels in natural waters; the effect of sunlight on the rate of chlorine decomposition in a swimming pool; and curriculum development in Australian agriculture science. (MLH)

  7. Unintentional Drowning

    MedlinePlus

    ... area unsupervised. If you are in and around natural water settings: Use U.S. Coast Guard approved life ... Swimming Pools CDC Feature Article: Drowning Risks in Natural Water Settings CDC: Recreational Water Illnesses (RWIs) CDC ...

  8. Operating and Maintaining Energy Smart Schools Action Plan Template - All Action Plans

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    none,

    2009-07-01

    EnergySmart Schools action plan templates for benchmarking, lighting, HVAC, water heating, building envelope, transformer, plug loads, kitchen equipment, swimming pool, building automation system, other.

  9. Monochromatic neutron beam production at Brazilian nuclear research reactors

    NASA Astrophysics Data System (ADS)

    Stasiulevicius, Roberto; Rodrigues, Claudio; Parente, Carlos B. R.; Voi, Dante L.; Rogers, John D.

    2000-12-01

    Monochomatic beams of neutrons are obtained form a nuclear reactor polychromatic beam by the diffraction process, suing a single crystal energy selector. In Brazil, two nuclear research reactors, the swimming pool model IEA-R1 and the Argonaut type IEN-R1 have been used to carry out measurements with this technique. Neutron spectra have been measured using crystal spectrometers installed on the main beam lines of each reactor. The performance of conventional- artificial and natural selected crystals has been verified by the multipurpose neutron diffractometers installed at IEA-R1 and simple crystal spectrometer in operator at IEN- R1. A practical figure of merit formula was introduced to evaluate the performance and relative reflectivity of the selected planes of a single crystal. The total of 16 natural crystals were selected for use in the neutron monochromator, including a total of 24 families of planes. Twelve of these natural crystal types and respective best family of planes were measured directly with the multipurpose neutron diffractometers. The neutron spectrometer installed at IEN- R1 was used to confirm test results of the better specimens. The usually conventional-artificial crystal spacing distance range is limited to 3.4 angstrom. The interplane distance range has now been increased to approximately 10 angstrom by use of naturally occurring crystals. The neutron diffraction technique with conventional and natural crystals for energy selection and filtering can be utilized to obtain monochromatic sub and thermal neutrons with energies in the range of 0.001 to 10 eV. The thermal neutron is considered a good tool or probe for general applications in various fields, such as condensed matter, chemistry, biology, industrial applications and others.

  10. Concentrations of disinfection by-products in swimming pool following modifications of the water treatment process: An exploratory study.

    PubMed

    Tardif, Robert; Rodriguez, Manuel; Catto, Cyril; Charest-Tardif, Ginette; Simard, Sabrina

    2017-08-01

    The formation and concentration of disinfection by-products (DBPs) in pool water and the ambient air vary according to the type of water treatment process used. This exploratory study was aimed at investigating the short-term impact of modifications of the water treatment process on traditional DBP levels (e.g., trihalomethanes (THMs), chloramines) and emerging DBPs (e.g., Halonitromethanes, Haloketones, NDMA) in swimming pool water and/or air. A sampling program was carried to understand the impact of the following changes made successively to the standard water treatment process: activation of ultraviolet (UV) photoreactor, halt of air stripping with continuation of air extraction from the buffer tank, halt of air stripping and suppression of air extraction from the buffer tank, suppression of the polyaluminium silicate sulfate (PASS) coagulant. UV caused a high increase of Halonitromethanes (8.4 fold), Haloketones (2.1 fold), and THMs in the water (1.7 fold) and, of THMs in the air (1.6 fold) and contributed to reducing the level of chloramines in the air (1.6 fold) and NDMA in the water (2.1 fold). The results highlight the positive impact of air stripping in reducing volatile contaminants. The PASS did not change the presence of DBPs, except for the THMs, which decrease slightly with the use of this coagulant. This study shows that modifications affecting the water treatment process can rapidly produce important and variable impacts on DBP levels in water and air and suggests that implementation of any water treatment process to reduce DBP levels should take into account the specific context of each swimming pool. Copyright © 2017. Published by Elsevier B.V.

  11. Sodium bisulfate poisoning

    MedlinePlus

    ... found in: Household cleaners Metal finishing Swimming pool pH additives Note: This list may not be all ... burns in the esophagus (food pipe) and the stomach (endoscopy) Chest x-ray EKG (electrocardiogram, or heart ...

  12. Wastewater treatment in a compact intensified wetland system at the Badboot: a floating swimming pool in Belgium.

    PubMed

    Van Oirschot, D; Wallace, S; Van Deun, R

    2015-09-01

    The Badboot (Dutch for swimming pool boat) is a floating swimming pool located in the city center of Antwerp in Belgium. The overall design consists of a recycled ferry boat that serves as a restaurant and next to that a newly built ship that harbours an Olympic size swimming pool, sun decks, locker rooms with showers, and a party space. A major design goal of the project was to make the ship as environmentally friendly as possible. To avoid discharge of contaminated waste water in the Antwerp docks, the ship includes onsite treatment of wastewater in a compact constructed wetland. The treatment wetland system was designed to treat wastewater from visitor locker rooms, showers, toilets, two bars, and the wastewater from the restaurant kitchen. Due to the limited space on board the ship, only 188 m(2) could be allocated to a wetland treatment system. As a result, part of the design included intensification of the wetland treatment process through the use of Forced Bed Aeration, which injects small quantities of air in a very uniform grid pattern throughout the wetland with a mechanical air compressor. The system was monitored between August 2012 and March 2013 (with additional sampling in the autumn of 2014). Flows and loads to the wetland were highly variable, but removal efficiency was extremely high; 99.5 % for chemical oxygen demand (COD), 88.6 % for total nitrogen and 97.2 % for ammonia. The treatment performance was assessed using a first-order, tanks-in-series model (the P-k-C* model) and found to be roughly equivalent to similar intensified wetlands operating in Germany. However, treatment performance was substantially better than data reported on passive wetlands, likely as a result of intensification. Even with mechanically assisted aeration, the total oxygen delivered to the treatment wetlands was insufficient to support conventional nitrification and denitrification, so it is likely that alternate nitrogen removal pathways, such as anammox, are operating in the wetland.

  13. Convective cooling in a pool-type research reactor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sipaun, Susan, E-mail: susan@nm.gov.my; Usman, Shoaib, E-mail: usmans@mst.edu

    2016-01-22

    A reactor produces heat arising from fission reactions in the nuclear core. In the Missouri University of Science and Technology research reactor (MSTR), this heat is removed by natural convection where the coolant/moderator is demineralised water. Heat energy is transferred from the core into the coolant, and the heated water eventually evaporates from the open pool surface. A secondary cooling system was installed to actively remove excess heat arising from prolonged reactor operations. The nuclear core consists of uranium silicide aluminium dispersion fuel (U{sub 3}Si{sub 2}Al) in the form of rectangular plates. Gaps between the plates allow coolant to passmore » through and carry away heat. A study was carried out to map out heat flow as well as to predict the system’s performance via STAR-CCM+ simulation. The core was approximated as porous media with porosity of 0.7027. The reactor is rated 200kW and total heat density is approximately 1.07+E7 Wm{sup −3}. An MSTR model consisting of 20% of MSTR’s nuclear core in a third of the reactor pool was developed. At 35% pump capacity, the simulation results for the MSTR model showed that water is drawn out of the pool at a rate 1.28 kg s{sup −1} from the 4” pipe, and predicted pool surface temperature not exceeding 30°C.« less

  14. Trihalomethanes in Lisbon indoor swimming pools: occurrence, determining factors, and health risk classification.

    PubMed

    Silva, Zelinda Isabel; Rebelo, Maria Helena; Silva, Manuela Manso; Alves, Ana Martins; Cabral, Maria da Conceição; Almeida, Ana Cristina; Aguiar, Fátima Rôxo; de Oliveira, Anabela Lopes; Nogueira, Ana Cruz; Pinhal, Hermínia Rodrigues; Aguiar, Pedro Manuel; Cardoso, Ana Sofia

    2012-01-01

    Characterization of water quality from indoor swimming pools, using chorine-based disinfection techniques, was performed during a 6-mo period to study the occurrence, distribution, and concentration factors of trihalomethanes (THM). Several parameters such as levels of water THM, water and air chloroform, water bromodichloromethane (BDCM), water dibromochloromethane (DBCM), water bromoform (BF), free residual chlorine (FrCl), pH, water and air temperature, and permanganate water oxidizability (PWO) were determined in each pool during that period. Chloroform (CF(W)) was the THM detected at higher concentrations in all pools, followed by BDCM, DBCM, and BF detected at 99, 34, and 6% of the samples, respectively. Water THM concentrations ranged from 10.1 to 155 μg/L, with 6.5% of the samples presenting values above 100 μg/L (parametric value established in Portuguese law DL 306/2007). In this study, air chloroform (CF(Air)) concentrations ranged from 45 to 373 μg/m³ with 24% of the samples presenting values above 136 μg/m³ (considered high exposure value). Several significant correlations were observed between total THM and other parameters, namely, CF(W), CF(Air), FrCl, water temperature (T(W)), and PWO. These correlations indicate that FrCl, T(W) and PWO are parameters that influence THM formation. The exposure criterion established for water THM enabled the inclusion of 67% of Lisbon pools in the high exposure group, which reinforces the need for an improvement in pool water quality.

  15. Assessment of three-dimensional joint kinematics of the upper limb during simulated swimming using wearable inertial-magnetic measurement units.

    PubMed

    Fantozzi, Silvia; Giovanardi, Andrea; Magalhães, Fabrício Anício; Di Michele, Rocco; Cortesi, Matteo; Gatta, Giorgio

    2016-01-01

    The analysis of the joint kinematics during swimming plays a fundamental role both in sports conditioning and in clinical contexts. Contrary to the traditional video analysis, wearable inertial-magnetic measurements units (IMMUs) allow to analyse both the underwater and aerial phases of the swimming stroke over the whole length of the swimming pool. Furthermore, the rapid calibration and short data processing required by IMMUs provide coaches and athletes with an immediate feedback on swimming kinematics during training. This study aimed to develop a protocol to assess the three-dimensional kinematics of the upper limbs during swimming using IMMUs. Kinematics were evaluated during simulated dry-land swimming trials performed in the laboratory by eight swimmers. A stereo-photogrammetric system was used as the gold standard. The results showed high coefficient of multiple correlation (CMC) values, with median (first-third quartile) of 0.97 (0.93-0.95) and 0.99 (0.97-0.99) for simulated front-crawl and breaststroke, respectively. Furthermore, the joint angles were estimated with an accuracy increasing from distal to proximal joints, with wrist indices showing median CMC values always higher than 0.90. The present findings represent an important step towards the practical use of technology based on IMMUs for the kinematic analysis of swimming in applied contexts.

  16. Simulated front crawl swimming performance related to critical speed and critical power.

    PubMed

    Toussaint, H M; Wakayoshi, K; Hollander, A P; Ogita, F

    1998-01-01

    Competitive pool swimming events range in distance from 50 to 1500 m. Given the difference in performance times (+/- 23-1000 s), the contribution of the aerobic and anaerobic energy systems changes considerably with race distance. In training practice the regression line between swimming distance and time (Distance = critical velocity x time + anaerobic swimming capacity) is used to determine the individual capacity of the aerobic and anaerobic metabolic pathways. Although there is confidence that critical velocity and anaerobic swimming capacity are fitness measures that separate aerobic and anaerobic components, a firm theoretical basis for the interpretation of these results does not exist. The purpose of this study was to evaluate the critical power concept and anaerobic swimming capacity as measures of the aerobic and anaerobic capacity using a modeling approach. A systems model was developed that relates the mechanics and energetics involved in front crawl swimming performance. From actual swimming flume measurements, the time dependent aerobic and anaerobic energy release was modeled. Data derived from the literature were used to relate the energy cost of front crawl swimming to swimming velocity. A balance should exist between the energy cost to swim a distance in a certain time and the concomitant aerobic and anaerobic energy release. The ensuing model was used to predict performance times over a range of distances (50-1500 m) and to calculate the regression line between swimming distance and time. Using a sensitivity analysis, it was demonstrated that the critical velocity is indicative for the capacity of the aerobic energy system. Estimates of the anaerobic swimming capacity, however, were influenced by variations in both anaerobic and aerobic energy release. Therefore, it was concluded that the anaerobic swimming capacity does not provide a reliable estimate of the anaerobic capacity.

  17. THE COOLING REQUIREMENTS AND PROCESS SYSTEMS OF THE SOUTH AFRICAN RESEARCH REACTOR, SAFARI 1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Colley, J.R.

    1962-12-01

    The SAFARI 1 research reactor is cooled and moderated by light water. There are three process systems, a primary water system which cools the reactor core and surroundings, a pool water system, and a secondary water system which removes the heat from the primary and pool systems. The cooling requirements for the reactor core and experimental facilities are outlined, and the cooling and purification functions of the three process systems are described. (auth)

  18. Giardiasis (For Parents)

    MedlinePlus

    ... their stool. The stool can then contaminate public water supplies, community swimming pools, and water sources like lakes ... normal amounts of chlorine used to purify community water supplies, and can live for more than 2 months ...

  19. 26 CFR 1.263A-8 - Requirement to capitalize interest.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... orders, and technological, design or other problems. To the extent that several distinct activities... time, such as swimming pools, roads, bridges, tunnels, paved parking areas and other pavements, special...

  20. 26 CFR 1.263A-8 - Requirement to capitalize interest.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... orders, and technological, design or other problems. To the extent that several distinct activities... time, such as swimming pools, roads, bridges, tunnels, paved parking areas and other pavements, special...

  1. 26 CFR 1.263A-8 - Requirement to capitalize interest.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... orders, and technological, design or other problems. To the extent that several distinct activities... time, such as swimming pools, roads, bridges, tunnels, paved parking areas and other pavements, special...

  2. 26 CFR 1.263A-8 - Requirement to capitalize interest.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... orders, and technological, design or other problems. To the extent that several distinct activities... time, such as swimming pools, roads, bridges, tunnels, paved parking areas and other pavements, special...

  3. Swimming Pools and Molluscum Contagiosum

    MedlinePlus

    ... Monkeypox Orf Virus (Sore Mouth Infection) Poxvirus and Rabies Branch Travelers’ Health: Smallpox & Other Orthopoxvirus-Associated Infections ... Monkeypox Orf Virus (Sore Mouth Infection) Poxvirus and Rabies Branch Travelers’ Health: Smallpox & Other Orthopoxvirus-Associated Infections ...

  4. Single Landmark Learning in Rats: Sex Differences in a Navigation Task

    ERIC Educational Resources Information Center

    Forcano, L.; Santamaria, J.; Mackintosh, N. J.; Chamizo, V. D.

    2009-01-01

    In Experiments 1 and 2, rats were trained in a Morris pool to find a hidden platform located some distance away from a single landmark. Males learned to swim to the platform faster than females, but on test trials without the platform, males, unlike females, spent less time in the platform quadrant of the pool in the second half of each test trial…

  5. Blood lactate accumulation in top level swimmers following competition.

    PubMed

    Bonifazi, M; Martelli, G; Marugo, L; Sardella, F; Carli, G

    1993-03-01

    The purposes of this study were to evaluate the significance of blood lactate values after competitions and the blood lactate-swimming speed relationship to swimming performances. Auricular blood samples (N = 421) were collected in 203 top level Italian swimmers (116 males and 87 females) at the end of competitions performed in a 25 m swimming pool. The distribution of all lactate values differed between males and females. The lowest lactate values occurred in swimmers performing the longest distances both in males (1500 m) and females (800 m). In swimmers performing freestyle events a relationship between V-4 mM (swimming speed at 4 mmol/l blood lactate value) and competition velocities was observed, in males, at 200, 400 and 1500 m and, in females, at 400 and 800 m. The predicted velocity corresponding to the competition lactate value assessed by the individual blood lactate-swimming speed relationship was found to be highly related to the actual competition velocity. Results suggest that blood lactate values in swimmers are a useful indication of individual aptitudes.

  6. Critical evaluation of oxygen-uptake assessment in swimming.

    PubMed

    Sousa, Ana; Figueiredo, Pedro; Pendergast, David; Kjendlie, Per-Ludvik; Vilas-Boas, João P; Fernandes, Ricardo J

    2014-03-01

    Swimming has become an important area of sport science research since the 1970s, with the bioenergetic factors assuming a fundamental performance-influencing role. The purpose of this study was to conduct a critical evaluation of the literature concerning oxygen-uptake (VO2) assessment in swimming, by describing the equipment and methods used and emphasizing the recent works conducted in ecological conditions. Particularly in swimming, due to the inherent technical constraints imposed by swimming in a water environment, assessment of VO2max was not accomplished until the 1960s. Later, the development of automated portable measurement devices allowed VO2max to be assessed more easily, even in ecological swimming conditions, but few studies have been conducted in swimming-pool conditions with portable breath-by-breath telemetric systems. An inverse relationship exists between the velocity corresponding to VO2max and the time a swimmer can sustain it at this velocity. The energy cost of swimming varies according to its association with velocity variability. As, in the end, the supply of oxygen (whose limitation may be due to central-O2 delivery and transportation to the working muscles-or peripheral factors-O2 diffusion and utilization in the muscles) is one of the critical factors that determine swimming performance, VO2 kinetics and its maximal values are critical in understanding swimmers' behavior in competition and to develop efficient training programs.

  7. Eye burning - itching and discharge

    MedlinePlus

    ... as chlorine in a swimming pool or makeup) Dry eyes Irritants in the air (cigarette smoke or smog) ... almost all causes of burning and irritation, especially dry eyes. If you have allergies, try to avoid the ...

  8. Comparative performance of twenty-three types of flat plate solar energy collectors

    NASA Technical Reports Server (NTRS)

    Simon, F. F.

    1975-01-01

    Report compares efficiencies of 23 solar collectors for four different purposes: operating a Rankine-cycle engine, heating or absorption air conditioning, heating hot water, and heating a swimming pool.

  9. Exercise-Induced Asthma

    MedlinePlus

    ... as triggers include: Cold air Dry air Air pollution High pollen counts Chlorine in swimming pools Chemicals used with ice rink resurfacing equipment Respiratory infections or other lung disease Activities with extended periods of deep breathing, such ...

  10. Pseudomonas Folliculitis Associated with Use of Hot Tubs and Spas.

    ERIC Educational Resources Information Center

    Ramsey, Michael L.

    1989-01-01

    Discusses the history, etiology, diagnosis, histopathology, treatment, and prevention of Pseudomonas Folliculitis, an increasingly common skin infection contracted in hot tubs and, to some extent, in swimming pools. (Author/SM)

  11. Handbook of dehumidification technology

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brundrett, G.W.

    1987-01-01

    This book shows how dehumidification can alleviate environmental problems in human and industrial spheres which carry major cost implications. The applications of dehumidification, sorbent, air cycle and refrigerant are outlined but the main emphasis is placed on the refrigerant cycle because its applications and product range are the most extensive. A more detailed review of the main applications and opportunities such as housing condensation problems, protection and control in industry and energy saving for swimming pools then follows. Specialist sections on food and flowers and the drying of pressurized gases precede chapters on future developments, economic aspects and a usefulmore » list of further information sources including active research centres. The Contents discussed are: Introduction . Principles . Design considerations for refrigerant dehumidifiers . Domestic applications and dehumidifiers . Swimming pools . Industrial dehumidification . Food and flowers . Drying high pressure gases . Future trends . Economics . Further sources of information.« less

  12. Application of underwater spectrometric system for survey of ponds of the MR reactor (NRC Kurchatov institute)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stepanov, Vyacheslav; Potapov, Victor; Safronov, Alexey

    2013-07-01

    The underwater spectrometric system for survey the bottom of material science multi-loop reactor MR ponds was elaborated. This system uses CdZnTe (CZT) detectors that allow for spectrometric measurements in high radiation fields. The underwater system was used in the spectrometric survey of the bottom of the MR reactor pool, as well as in the survey located in the MR storage pool of highly radioactive containers and parts of the reactor construction. As a result of these works irradiated nuclear fuel was detected on the bottom of pools, and obtained estimates of the effective surface activity detected radionuclides and created bymore » them the dose rate. (authors)« less

  13. An Innovative Hybrid Loop-Pool SFR Design and Safety Analysis Methods: Today and Tomorrow

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hongbin Zhang; Haihua Zhao; Vincent Mousseau

    2008-04-01

    Investment in commercial sodium cooled fast reactor (SFR) power plants will become possible only if SFRs achieve economic competitiveness as compared to light water reactors and other Generation IV reactors. Toward that end, we have launched efforts to improve the economics and safety of SFRs from the thermal design and safety analyses perspectives at Idaho National Laboratory. From the thermal design perspective, an innovative hybrid loop-pool SFR design has been proposed. This design takes advantage of the inherent safety of a pool design and the compactness of a loop design to further improve economics and safety. From the safety analysesmore » perspective, we have initiated an effort to develop a high fidelity reactor system safety code.« less

  14. Going with the flow or swimming against the tide: should children with central venous catheters swim?

    PubMed

    Miller, Jessica; Dalton, Meghan K; Duggan, Christopher; Lam, Shirley; Iglesias, Julie; Jaksic, Tom; Gura, Kathleen M

    2014-02-01

    Children who require long-term parenteral nutrition (PN) have central venous catheters (CVCs) in place to allow the safe and effective infusion of life-sustaining fluids and nutrition. Many consider recreational swimming to be a common part of childhood, but for some, the risk may outweigh the benefit. Children with CVCs may be at increased risk of exit site, tunnel, and catheter-related bloodstream infections (CRBSIs) if these catheters are immersed in water. The purpose of this review is to evaluate the current literature regarding the risk of infection for patients with CVCs who swim and determine if there is consensus among home PN (HPN) programs on this controversial issue. A total 45 articles were reviewed and 16 pediatric HPN programs were surveyed regarding swimming and CVCs. Due to the limited data available, a firm recommendation cannot be made. Recreational water associated outbreaks are well documented in the general public, as is the presence of human pathogens even in chlorinated swimming pools. As a medical team, practitioners can provide information and education regarding the potential risk, but ultimately the decision lies with the parents. If the parents decide swimming is worth the risk, they are encouraged to use products designed for this use and to change their child's dressing immediately after swimming. Due to our experience with a fatal event immediately after swimming, we continue to strongly discourage patients with CVCs from swimming. Further large and well-designed studies regarding the risk of swimming with a CVC are needed to make a strong, evidence-based recommendation.

  15. The Body Mass Index of San Francisco Cold-water Swimmers: Comparisons to U.S. National and Local Populations, and Pool Swimmers

    PubMed Central

    CROW, BRENDAN T.; MATTHAY, ELLICOTT C.; SCHATZ, STEPHEN P.; DEBELISO, MARK D.; NUCKTON, THOMAS J.

    2017-01-01

    To determine if cold-water swimmers have substantial differences in BMI, which might have a protective effect against heat loss during swims in cold water without wetsuits, and to determine if obesity is more or less prevalent in cold-water swimmers, we compared the body mass index (BMI) values of 103 recreational open-water swimmers (mean age 54.3 ±10.8 years) to data from various population groups. Swimmers swam consistently throughout the winter months, in the San Francisco Bay (water temperature range: 9.6° C [49.3 ° F] to 12.6° C [54.7 ° F]), without wetsuits. After matching for age and sex, the average BMI of cold-water swimmers (25.9 kg/m2) was lower than the corresponding predicted U.S. average BMI (29.2 kg/m2; p<.001), the predicted California state average BMI (28.0 kg/m2; p<.001), and the predicted San Francisco city average BMI (26.6 kg/m2; p=.047). The average BMI value for cold-water swimmers (25.9 kg/m2) was not significantly different from values of North American masters pool swimmers (25.1 kg/m2; p=.15) or international masters pool swimmers (25.3 kg/m2; p=.16). 10.7% of cold-water swimmers were classified as obese (BMI > 30 kg/m2) vs. 35.7%, 25.8%, and 11.8% of the U.S., California, and San Francisco populations, respectively. The lower or similar BMI values of our swimmers suggest that successful recreational swimming in cold water is influenced by factors other than body habitus, such as acclimatization, heat production while swimming, and most importantly, limiting immersion time. The relatively low prevalence of obesity in our swimmers suggests that cold-water swimming could contribute to a healthy lifestyle. PMID:29399251

  16. Hospital hydrotherapy pools treated with ultra violet light: bad bacteriological quality and presence of thermophilic Naegleria.

    PubMed Central

    De Jonckheere, J. F.

    1982-01-01

    The microbiological quality of eight halogenated and two u.v.-treated hydrotherapy pools in hospitals was investigated. The microbiological quality of halogenated hydrotherapy pools was comparable to halogenated public swimming pools, although in some Pseudomonas aeruginosa and faecal pollution indicators were more frequent due to bad management. On the other hand u.v.-treated hydrotherapy pools had very bad microbiological quality. Apart from faecal pollution indicators, P. aeruginosa was present in very high numbers. Halogenated hydrotherapy pools were not highly contaminated with amoebae, and Naegleria spp. were never detected. On the other hand u.v.-treated pools contained very high numbers of thermophilic Naegleria. The Naegleria isolated were identified as N. lovaniensis, a species commonly found in association with N. fowleri. Isoenzyme analysis showed a different type of N. lovaniensis was present in each of two u.v.-treated pools. Images Plate 1 PMID:7061835

  17. Favourable impact of regular swimming in young people with haemophilia: experience derived from 'Desafio del Caribe' project.

    PubMed

    Boadas, A; Osorio, M; Gibraltar, A; Rosas, M M; Berges, A; Herrera, E; Gadea, S; Gutiérrez, M Á; Salazar, F; Ruiz-Sáez, A

    2015-01-01

    Swimming is beneficial for persons with haemophilia (PWH) providing good maintenance of the cardiovascular and musculoskeletal system and improving many psychological characteristics. In the Desafío del Caribe Project, young PWH from Venezuela and Mexico took part in an open water competition in the Gulf of Mexico under a multidisciplinary team supervision. Eight severe haemophilia A, two moderate haemophilia A, one severe haemophilia B and two moderate haemophilia B subjects were included. Haematological, musculoskeletal and psychological evaluations were carried out before and during training for the competition. Training program included physical exercise routines and swimming practices that alternated between pools and open water. Swimmers had coverage with factor concentrates before pool and open water trainings. In physiatric evaluations, the Hemophilia Joint Health Score (HJHS) was used. The objective of the psychology area was to analyse self-esteem, precompetition anxiety, coping mechanisms and relaxation levels. The need of factor prophylaxis before intense trainings was confirmed. In the musculoskeletal system a decrease of elbow pain as well as an increase of muscle strength in the ankles were observed. In the psychological area significant differences between the first and second test in self-esteem levels, cognitive anxiety and group cohesion were found. PWH must be provided with orientation and encouragement to practice swimming regularly. High competition exercise must be supervised by a multidisciplinary team which must evaluate the pros and cons of the activity to make relevant recommendations. © 2014 John Wiley & Sons Ltd.

  18. Shared Components of Rhythm Generation for Locomotion and Scratching Exist Prior to Motoneurons

    PubMed Central

    Hao, Zhao-Zhe; Berkowitz, Ari

    2017-01-01

    Does the spinal cord use a single network to generate locomotor and scratching rhythms or two separate networks? Previous research showed that simultaneous swim and scratch stimulation (“dual stimulation”) in immobilized, spinal turtles evokes a single rhythm in hindlimb motor nerves with a frequency often greater than during swim stimulation alone or scratch stimulation alone. This suggests that the signals that trigger swimming and scratching converge and are integrated within the spinal cord. However, these results could not determine whether the integration occurs in motoneurons themselves or earlier, in spinal interneurons. Here, we recorded intracellularly from hindlimb motoneurons during dual stimulation. Motoneuron membrane potentials displayed regular oscillations at a higher frequency during dual stimulation than during swim or scratch stimulation alone. In contrast, arithmetic addition of the oscillations during swimming alone and scratching alone with various delays always generated irregular oscillations. Also, the standard deviation of the phase-normalized membrane potential during dual stimulation was similar to those during swimming or scratching alone. In contrast, the standard deviation was greater when pooling cycles of swimming alone and scratching alone for two of the three forms of scratching. This shows that dual stimulation generates a single rhythm prior to motoneurons. Thus, either swimming and scratching largely share a rhythm generator or the two rhythms are integrated into one rhythm by strong interactions among interneurons. PMID:28848402

  19. Homemade Solar Systems

    NASA Technical Reports Server (NTRS)

    1981-01-01

    Through the use of NASA Tech Briefs, Peter Kask, was able to build a solarized domestic hot water system. Also by applying NASA's solar energy design information, he was able to build a swimming pool heating system with minimal outlay for materials.

  20. 75 FR 56597 - University of Wisconsin; University of Wisconsin Nuclear Reactor Environmental Assessment and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-09-16

    ...,000 gallons being typical. The licensee maintains a pool leak surveillance program. The pool water leak surveillance program continues to monitor the pool water evaporation rate, the pool water make-up volume, and pool water radioactivity. The pool leak surveillance program indicated that approximately 2...

  1. VIEW OF EAST SIDE OF FILTER ROOM/BATHHOUSE BUILDING S196, FACING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    VIEW OF EAST SIDE OF FILTER ROOM/BATHHOUSE BUILDING S-196, FACING SOUTHWEST. - U.S. Naval Base, Pearl Harbor, Outdoor Swimming Pool, Corner of Liscome Bay Street & St. Lo Avenue, Pearl City, Honolulu County, HI

  2. 77 FR 28372 - South Carolina Public Service Authority; Notice of Application for Amendment of License and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-14

    ... marina, fuel and sewage pump-out services, restrooms, parking, shops, restaurant, swimming pool, rental... and Service of Responsive Documents: Any filing must (1) bear in all capital letters the title...

  3. Chemical Emergency Preparedness and Prevention Advisory: Swimming Pool Chemicals: Chlorine

    EPA Pesticide Factsheets

    This June 1990 advisory to Local Emergency Planning Committees (LEPCs) suggests they address risk from chlorine, an extremely hazardous substance, even when below the threshold planning quantity stated in Emergency Planning and Community Right-to-Know Act.

  4. 13 CFR 115.12 - General program policies and provisions.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... establishment, aquarium, zoo, golf course or swimming pool, or the Contract Obligee has one of the following...—“Other Gambling Industries”; (iv) 713910—“Golf Courses and Country Clubs”; (v) 712130—“Zoos and Botanical...

  5. 13 CFR 115.12 - General program policies and provisions.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... establishment, aquarium, zoo, golf course or swimming pool, or the Contract Obligee has one of the following...—“Other Gambling Industries”; (iv) 713910—“Golf Courses and Country Clubs”; (v) 712130—“Zoos and Botanical...

  6. 13 CFR 115.12 - General program policies and provisions.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... establishment, aquarium, zoo, golf course or swimming pool, or the Contract Obligee has one of the following...—“Other Gambling Industries”; (iv) 713910—“Golf Courses and Country Clubs”; (v) 712130—“Zoos and Botanical...

  7. 13 CFR 115.12 - General program policies and provisions.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... establishment, aquarium, zoo, golf course or swimming pool, or the Contract Obligee has one of the following...—“Other Gambling Industries”; (iv) 713910—“Golf Courses and Country Clubs”; (v) 712130—“Zoos and Botanical...

  8. 13 CFR 115.12 - General program policies and provisions.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... establishment, aquarium, zoo, golf course or swimming pool, or the Contract Obligee has one of the following...—“Other Gambling Industries”; (iv) 713910—“Golf Courses and Country Clubs”; (v) 712130—“Zoos and Botanical...

  9. Sex differences on the competitive place task in the water maze: The influence of peripheral pool time on spatial navigation performance in rats.

    PubMed

    Devan, Bryan D; Tobin, Elizabeth L; Dunn, Emily N; Magalis, Christopher

    2016-11-01

    This study investigated sex differences on the competitive place version of the Morris water maze task to determine whether potential strategy differences would emerge during any phase of the study but in particular on the competitive place phase. Previous findings indicate that this version of the task is highly sensitive to measures that disrupt NMDA-dependent synaptic plasticity within the hippocampus during memory consolidation (McDonald et al., 2005). The present findings revealed significant sex differences during all phases of the study, including Phase I with standard place training to located a hidden platform/goal, Phase II mass training to a new place with the platform/goal relocated to the diagonally opposite quadrant and Phase III, competitive place probe test with the platform removed to measure spatial behaviour directed at either location. The findings showed no sex difference in escape latency and other standard performance measures during the first two phases, initial place acquisition and mass training to a new location. A very subtle male advantage in visiting both Old and New place locations during the third phase place competition test was observed, however, in the time spent swimming in the periphery of the pool, the pool wall (Zone C - outer third radial distance) was increased for females during all phases of the study, suggesting a general effect may have influenced place location search behaviour of the females. Increased peripheral pool time may represent a female preference for approaching the wall, a local cue. Alternatively, the possibility that increased peripheral swimming/thigmotaxis may represent hormonal influences interacting with strategic preferences were discussed, though no definitive conclusions about sex differences in cognitive-spatial performance or memory consolidation were inferred from the present findings. The findings suggest that mixed results reported in the literature by others may be due in part to an interaction with a persistent peripheral pool swimming response demonstrated in female rats. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. Emergency core cooling system

    DOEpatents

    Schenewerk, William E.; Glasgow, Lyle E.

    1983-01-01

    A liquid metal cooled fast breeder reactor provided with an emergency core cooling system includes a reactor vessel which contains a reactor core comprising an array of fuel assemblies and a plurality of blanket assemblies. The reactor core is immersed in a pool of liquid metal coolant. The reactor also includes a primary coolant system comprising a pump and conduits for circulating liquid metal coolant to the reactor core and through the fuel and blanket assemblies of the core. A converging-diverging venturi nozzle with an intermediate throat section is provided in between the assemblies and the pump. The intermediate throat section of the nozzle is provided with at least one opening which is in fluid communication with the pool of liquid sodium. In normal operation, coolant flows from the pump through the nozzle to the assemblies with very little fluid flowing through the opening in the throat. However, when the pump is not running, residual heat in the core causes fluid from the pool to flow through the opening in the throat of the nozzle and outwardly through the nozzle to the assemblies, thus providing a means of removing decay heat.

  11. Creatine supplementation and swim performance: a brief review.

    PubMed

    Hopwood, Melissa J; Graham, Kenneth; Rooney, Kieron B

    2006-03-01

    Nutritional supplements are popular among athletes participating in a wide variety of sports. Creatine is one of the most commonly used dietary supplements, as it has been shown to be beneficial in improving performance during repeated bouts of high-intensity anaerobic activity. This review examines the specific effects of creatine supplementation on swimming performance, and considers the effects of creatine supplementation on various measures of power development in this population. Research performed on the effect of creatine supplementation on swimming performance indicates that whilst creatine supplementation is ineffective in improving performance during a single sprint swim, dietary creatine supplementation may benefit repeated interval swim set performance. Considering the relationship between sprint swimming performance and measurements of power, the effect of creatine supplementation on power development in swimmers has also been examined. When measured on a swim bench ergometer, power development does show some improvement following a creatine supplementation regime. How this improvement in power output transfers to performance in the pool is uncertain. Although some evidence exists to suggest a gender effect on the performance improvements seen in swimmers following creatine supplementation, the majority of research indicates that male and female swimmers respond equally to supplementation. A major limitation to previous research is the lack of consideration given to the possible stroke dependant effect of creatine supplementation on swimming performance. The majority of the research conducted to date has involved examination of the freestyle swimming stroke only. The potential for performance improvements in the breaststroke and butterfly swimming strokes is discussed, with regards to the biomechanical differences and differences in efficiency between these strokes and freestyle. Key PointsCreatine supplementation does not improve single sprint swimming performance.Creatine supplementation does improve repeated interval swim set performance.Creatine supplementation does improve power development in swimmers when measured on a swim bench ergometer.As a result of the high energy demands of the butterfly and breaststroke competitive swimming styles, potentially, the benefits associated with creatine supplementation and swimming performance could be greater when swimming butterfly or breaststroke, compared to the commonly examined freestyle swimming stroke.

  12. Drowning in Pretoria, South Africa: A 10-year review.

    PubMed

    Morris, N K; du Toit-Prinsloo, L; Saayman, G

    2016-01-01

    Drowning is classified as the 3rd leading cause of accidental deaths worldwide and is deemed to be a preventable cause of death. Bodies retrieved from a water medium pose several challenges to the forensic pathologist with the diagnosis of drowning being primarily one of exclusion. The aim of this study was to do a retrospective descriptive case audit of bodies retrieved from water and immersion related deaths, which were investigated at the Pretoria Medico-Legal Laboratory (PMLL) over a 10 year period (January 2002 through December 2011). A total of 346 cases were identified for inclusion into this study. In 6% (20) of these cases, the death was not related to drowning; in 14% (48) no clear cause of death could be ascertained and in 278 cases (80%) the cause of death was considered to have been due to drowning. Infants (under 1 year, of age) constituted 41 (15%) of the cases; toddlers (aged 1-2 years) comprised 52 (19%) cases; children (aged 2-13 years) 49 (18%) cases; adolescents (aged 13-18 years) comprised 10 (3%) cases; adults (above 18, years) made up 126 (45%) of the cases. The majority of the drownings, occurred in swimming pools [125 cases (38%)]. In infants 23 (56%) of, drownings occurred in swimming pools followed by buckets [7 cases (17%)]. Sixty-nine per cent of toddler drownings (36 cases) occurred in swimming, pools. In the adult population, 40 (32%) of cases occurred in pools and 35 cases (28%) in rivers. Positive blood alcohol results were recorded in 48, (42%) out of 113 cases where the test was requested, 40 (35%) of these, cases higher than 0.05 g per 100 ml. This study suggests that many drowning deaths in Pretoria may be preventable by introducing greater public awareness of the risks and instituting relatively simple, protective measures. Copyright © 2015 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.

  13. A new safety channel based on ¹⁷N detection in research reactors.

    PubMed

    Seyfi, Somayye; Gharib, Morteza

    2015-10-01

    Tehran research reactor (TRR) is a representative of pool type research reactors using light water, as coolant and moderator. This reactor is chosen as a prototype to demonstrate and prove the feasibility of (17)N detection as a new redundant channel for reactor power measurement. In TRR, similar to other pool type reactors, neutron detectors are immersed in the pool around the core as the main power measuring devices. In the present article, a different approach, using out of water neutron detector, is employed to measure reactor power. This new method is based on (17)O (n,p) (17)N reaction taking place inside the core and subsequent measurement of delayed neutrons emitted due to (17)N disintegration. Count and measurement of neutrons around outlet water pipe provides a reliable redundant safety channel to measure reactor power. Results compared with other established channels indicate a good agreement and shows a linear interdependency with true thermal power. Safety of reactor operation is improved with installation & use of this new power measuring channel. The new approach may equally serve well as a redundant channel in all other types of reactors having coolant comprised of oxygen in its molecular constituents. Contrary to existing channels, this one is totally out of water and thus is an advantage over current instrumentations. It is proposed to employ the same idea on other reactors (nuclear power plants too) to improve safety criteria. Copyright © 2015 Elsevier Ltd. All rights reserved.

  14. Socioeconomic status and exposure to disinfection by-products in drinking water in Spain.

    PubMed

    Castaño-Vinyals, Gemma; Cantor, Kenneth P; Villanueva, Cristina M; Tardon, Adonina; Garcia-Closas, Reina; Serra, Consol; Carrato, Alfredo; Malats, Núria; Rothman, Nathaniel; Silverman, Debra; Kogevinas, Manolis

    2011-03-16

    Disinfection by-products in drinking water are chemical contaminants that have been associated with cancer and other adverse effects. Exposure occurs from consumption of tap water, inhalation and dermal absorption. We determined the relationship between socioeconomic status and exposure to disinfection by-products in 1271 controls from a multicentric bladder cancer case-control study in Spain. Information on lifetime drinking water sources, swimming pool attendance, showering-bathing practices, and socioeconomic status (education, income) was collected through personal interviews. The most highly educated subjects consumed less tap water (57%) and more bottled water (33%) than illiterate subjects (69% and 17% respectively, p-value = 0.003). These differences became wider in recent time periods. The time spent bathing or showering was positively correlated with attained educational level (p < 0.001). Swimming pool attendance was more frequent among highly educated subjects compared to the illiterate (odds ratio = 3.4; 95% confidence interval 1.6-7.3). The most highly educated subjects were less exposed to chlorination by-products through ingestion but more exposed through dermal contact and inhalation in pools and showers/baths. Health risk perceptions and economic capacity may affect patterns of water consumption that can result in differences in exposure to water contaminants.

  15. Preventing Community-wide Transmission of Cryptosporidium: A Proactive Public Health Response to a Swimming Pool–Associated Outbreak — Auglaize County, Ohio, USA

    PubMed Central

    Cope, J.R.; Prosser, A.; Nowicki, S.; Roberts, M.W.; Scheer, D.; Anderson, C.; Longsworth, A.; Parsons, C.; Goldschmidt, D.; Johnston, S.; Bishop, H.; Xiao, L.; Hill, V.; Beach, M.; Hlavsa, M.C.

    2015-01-01

    Summary The incidence of recreational water–associated outbreaks in the United States has significantly increased, driven, at least in part, by outbreaks both caused by Cryptosporidium and associated with treated recreational water venues. Because of the parasite's extreme chlorine tolerance, transmission can occur even in well-maintained treated recreational water venues, (e.g., pools) and a focal cryptosporidiosis outbreak can evolve into a community-wide outbreak associated with multiple recreational water venues and settings (e.g., child care facilities). In August 2004 in Auglaize County, Ohio, multiple cryptosporidiosis cases were identified and anecdotally linked to Pool A. Within 5 days of the first case being reported, Pool A was hyperchlorinated to achieve 99.9% Cryptosporidium inactivition. A case-control study was launched to epidemiologically ascertain the outbreak source 11 days later. A total of 150 confirmed and probable cases were identified; the temporal distribution of illness onset was peaked, indicating a point-source exposure. Cryptosporidiosis was significantly associated with swimming in Pool A (matched odds ratio 121.7, 95% confidence interval 27.4–∞) but not with another venue or setting. The findings of this investigation suggest that proactive implementation of control measures, when increased Cryptosporidium transmission is detected but before an outbreak source is epidemiologically ascertained, might prevent a focal cryptosporidiosis outbreak from evolving into a community-wide outbreak. PMID:25907106

  16. Use of the Term “Shock” in Swimming Pool, Hot Tubs, and Spa Products

    EPA Pesticide Factsheets

    EPA has determined that shock treatment and super-chlorination are terms usually used to describe claims to kill or control visible algae growth. Claims to kill, prevent or control algae or bacteria are pesticide claims.

  17. Shades of Summer.

    ERIC Educational Resources Information Center

    Greenman, Geri

    2001-01-01

    Describes an art project in which noodles, the tubular colorful foam floating devices used in swimming pools, were the subject matter. Explains that the students drew their compositions, stretched the paper, and then used watercolor to paint their compositions. Discusses the process in detail. (CMK)

  18. VIEW OF SOUTH AND EAST SIDES OF FILTER ROOM/BATHHOUSE BUILDING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    VIEW OF SOUTH AND EAST SIDES OF FILTER ROOM/BATHHOUSE BUILDING S-196, FACING NORTHWEST. - U.S. Naval Base, Pearl Harbor, Outdoor Swimming Pool, Corner of Liscome Bay Street & St. Lo Avenue, Pearl City, Honolulu County, HI

  19. VIEW OF NORTH AND WEST SIDES OF FILTER ROOM/BATHHOUSE BUILDING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    VIEW OF NORTH AND WEST SIDES OF FILTER ROOM/BATHHOUSE BUILDING S-196, FACING SOUTHEAST. - U.S. Naval Base, Pearl Harbor, Outdoor Swimming Pool, Corner of Liscome Bay Street & St. Lo Avenue, Pearl City, Honolulu County, HI

  20. Plasma renin activity, aldosterone and catecholamine levels when swimming and running.

    PubMed

    Guezennec, C Y; Defer, G; Cazorla, G; Sabathier, C; Lhoste, F

    1986-01-01

    The purpose of this study was to determine the response of plasma renin activity (PRA), plasma aldosterone concentration (PAC) and catecholamines to two graded exercises differing by posture. Seven male subjects (19-25 years) performed successively a running rest on a treadmill and a swimming test in a 50-m swimming pool. Each exercise was increased in severity in 5-min steps with intervals of 1 min. Oxygen consumption, heart rate and blood lactate, measured every 5 min, showed a similar progression in energy expenditure until exhaustion, but there was a shorter time to exhaustion in the last step of the running test. PRA, PAC and catecholamines were increased after both types of exercise. The PRA increase was higher after the running test (20.9 ng AngI X ml-1 X h-1) than after swimming (8.66 ng AngI X ml-1 X h-1). The PAC increase was slightly greater after running (123 pg X ml-1) than swimming (102 pg X ml-1), buth the difference was not significant. Plasma catecholamine was higher after the swimming test. These results suggest that the volume shift induced by the supine position and water pressure during swimming decreased the PRA response. The association after swimming compared to running of a decreased PRA and an enhanced catecholamine response rule out a strict dependence of renin release under the effect of plasma catecholamines and is evidence of the major role of neural pathways for renin secretion during physical exercise.

  1. London 2012 Paralympic swimming: passive drag and the classification system.

    PubMed

    Oh, Yim-Taek; Burkett, Brendan; Osborough, Conor; Formosa, Danielle; Payton, Carl

    2013-09-01

    The key difference between the Olympic and Paralympic Games is the use of classification systems within Paralympic sports to provide a fair competition for athletes with a range of physical disabilities. In 2009, the International Paralympic Committee mandated the development of new, evidence-based classification systems. This study aims to assess objectively the swimming classification system by determining the relationship between passive drag and level of swimming-specific impairment, as defined by the current swimming class. Data were collected on participants at the London 2012 Paralympic Games. The passive drag force of 113 swimmers (classes 3-14) was measured using an electro-mechanical towing device and load cell. Swimmers were towed on the surface of a swimming pool at 1.5 m/s while holding their most streamlined position. Passive drag ranged from 24.9 to 82.8 N; the normalised drag (drag/mass) ranged from 0.45 to 1.86 N/kg. Significant negative associations were found between drag and the swimming class (τ = -0.41, p < 0.01) and normalised drag and the swimming class (τ = -0.60, p < 0.01). The mean difference in drag between adjacent classes was inconsistent, ranging from 0 N (6 vs 7) to 11.9 N (5 vs 6). Reciprocal Ponderal Index (a measure of slenderness) correlated moderately with normalised drag (r(P) = -0.40, p < 0.01). Although swimmers with the lowest swimming class experienced the highest passive drag and vice versa, the inconsistent difference in mean passive drag between adjacent classes indicates that the current classification system does not always differentiate clearly between swimming groups.

  2. The Muon System of the Daya Bay Reactor Antineutrino Experiment

    DOE PAGES

    An, F. P.; Hackenburg, R. W.; Brown, R. E.; ...

    2014-10-05

    The Daya Bay experiment consists of functionally identical antineutrino detectors immersed in pools of ultrapure water in three well-separated underground experimental halls near two nuclear reactor complexes. These pools serve both as shields against natural, low-energy radiation, and as water Cherenkov detectors that efficiently detect cosmic muons using arrays of photomultiplier tubes. Each pool is covered by a plane of resistive plate chambers as an additional means of detecting muons. Design, construction, operation, and performance of these muon detectors are described. (auth)

  3. Natural Circulation Level Optimization and the Effect during ULOF Accident in the SPINNOR Reactors

    NASA Astrophysics Data System (ADS)

    Abdullah, Ade Gafar; Su'ud, Zaki; Kurniadi, Rizal; Kurniasih, Neny; Yulianti, Yanti

    2010-12-01

    Natural circulation level optimization and the effect during loss of flow accident in the 250 MWt MOX fuelled small Pb-Bi Cooled non-refueling nuclear reactors (SPINNOR) have been performed. The simulation was performed using FI-ITB safety code which has been developed in ITB. The simulation begins with steady state calculation of neutron flux, power distribution and temperature distribution across the core, hot pool and cool pool, and also steam generator. When the accident is started due to the loss of pumping power the power distribution and the temperature distribution of core, hot pool and cool pool, and steam generator change. Then the feedback reactivity calculation is conducted, followed by kinetic calculation. The process is repeated until the optimum power distribution is achieved. The results show that the SPINNOR reactor has inherent safety capability against this accident.

  4. PWR upper/lower internals shield

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Homyk, W.A.

    1995-03-01

    During refueling of a nuclear power plant, the reactor upper internals must be removed from the reactor vessel to permit transfer of the fuel. The upper internals are stored in the flooded reactor cavity. Refueling personnel working in containment at a number of nuclear stations typically receive radiation exposure from a portion of the highly contaminated upper intervals package which extends above the normal water level of the refueling pool. This same issue exists with reactor lower internals withdrawn for inservice inspection activities. One solution to this problem is to provide adequate shielding of the unimmersed portion. The use ofmore » lead sheets or blankets for shielding of the protruding components would be time consuming and require more effort for installation since the shielding mass would need to be transported to a support structure over the refueling pool. A preferable approach is to use the existing shielding mass of the refueling pool water. A method of shielding was devised which would use a vacuum pump to draw refueling pool water into an inverted canister suspended over the upper internals to provide shielding from the normally exposed components. During the Spring 1993 refueling of Indian Point 2 (IP2), a prototype shield device was demonstrated. This shield consists of a cylindrical tank open at the bottom that is suspended over the refueling pool with I-beams. The lower lip of the tank is two feet below normal pool level. After installation, the air width of the natural shielding provided by the existing pool water. This paper describes the design, development, testing and demonstration of the prototype device.« less

  5. Applying physiological principles and assessment techniques to swimming the English Channel. A case study.

    PubMed

    Acevedo, E O; Meyers, M C; Hayman, M; Haskin, J

    1997-03-01

    This study presents the use of physiological principles and assessment techniques in addressing four objectives that can enhance a swimmer's likelihood of successfully swimming the English Channel. The four objective were: (1) to prescribe training intensities and determine ideal swimming pace; (2) to determine the amount of insulation needed, relative to heat produced, to diminish the likelihood of the swimmer suffering from hypothermia; (3) to calculate the caloric expenditure for the swim and the necessary glucose replacement required to prevent glycogen depletion; and (4) to determine the rate of acclimatization to cold water (15.56 C/60 F). The subject participated in several pool swimming data collection sessions including a tethered swim incremental protocol to determine peak oxygen consumption and onset of lactate accumulation and several steady state swims to determine ideal swimming pace at 4.0 mM/L of lactate. Additionally, these swims provided information on oxygen consumption, which in combination with ultrasound assessment of subcutaneous fat was used to assess heat production and insulation capabilities. Finally, the subject participated in 18 cold water immersions to document acclimatization rate. The data demonstrated the high fitness level of this subject and indicated that at a stroke rate of 63 stokes/min, HR was 130 heats/min and lactate was 4 mM/L. At this swimming pace the swimmer would need to consume 470 kcal of glucose/hr. In addition, the energy produced at this swim pace was 13.25 kcal/min while the energy lost at the present subcutaneous fat quantity was 13.40 kcal/min, requiring a fat weight gain of 6,363.03 g (13.88 lbs) to resist heat loss. Finally, the data from the cold water immersions suggested that acclimatization occurred following two weeks of immersions. There results were provided to the swimmer and utilized in making decisions in preparation for the swim.

  6. 12. Photocopy of photograph (original located in Photograph's Office, Hawthorne ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    12. Photocopy of photograph (original located in Photograph's Office, Hawthorne Army Ammunition Plant, Hawthorne, Nevada). View of swimming pool, photograph no. 20107-27. - Hawthorne Naval Ammunition Depot, Gymnasium, North Main Avenue, Industrial Area, Hawthorne Army Ammunition Plant, Hawthorne, Mineral County, NV

  7. Wet--But Safe. A Classroom Course in Water Safety and Survival.

    ERIC Educational Resources Information Center

    Michigan State Dept. of Natural Resources, Lansing.

    This manual is designed for use in elementary school systems that do not have a swimming pool available. It contains eight classroom sessions and provides a core of information in basic water safety, water survival, and water rescue. (JD)

  8. Dive In to Aquatic Circuits.

    ERIC Educational Resources Information Center

    Goldfarb, Joseph M.

    1995-01-01

    The article presents a method for swimming teachers and coaches to stave off workout boredom in their students by using a circuit in the pool. After explaining how to set up a training circuit, the article describes sample stations and notes important safety precautions. (SM)

  9. 16 CFR 1207.3 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Definitions. 1207.3 Section 1207.3 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION CONSUMER PRODUCT SAFETY ACT REGULATIONS SAFETY... use means behavior on swimming pool slides as disclosed by the manufacturer, as specified in this part...

  10. ADVANCED REACTIVITY MEASUREMENT FACILITY, TRA660, INTERIOR. REACTOR INSIDE TANK. METAL ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    ADVANCED REACTIVITY MEASUREMENT FACILITY, TRA-660, INTERIOR. REACTOR INSIDE TANK. METAL WORK PLATFORM ABOVE. THE REACTOR WAS IN A SMALL WATER-FILLED POOL. INL NEGATIVE NO. 66-6373. Unknown Photographer, ca. 1966 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID

  11. Time limit and VO2 slow component at intensities corresponding to VO2max in swimmers.

    PubMed

    Fernandes, R J; Cardoso, C S; Soares, S M; Ascensão, A; Colaço, P J; Vilas-Boas, J P

    2003-11-01

    The purpose of this study was to measure, in swimming pool conditions and with high level swimmers, the time to exhaustion at the minimum velocity that elicits maximal oxygen consumption (TLim at vVO(2)max), and the corresponding VO(2) slow component (O(2)SC). The vVO(2)max was determined through an intermittent incremental test (n = 15). Forty-eight hours later, TLim was assessed using an all-out swim at vVO(2)max until exhaustion. VO(2) was measured through direct oximetry and the swimming velocity was controlled using a visual light-pacer. Blood lactate concentrations and heart rate values were also measured. Mean VO(2)max for the incremental test was 5.09 +/- 0.53 l/min and the corresponding vVO(2)max was 1.46 +/- 0.06 m/s. Mean TLim value was 260.20 +/- 60.73 s and it was inversely correlated with the velocity of anaerobic threshold (r = -0.54, p < 0.05). This fact, associated with the inverse relationship between TLim and vVO(2)max (r = -0.47, but only for p < 0.10), suggested that swimmers' lower level aerobic metabolic rate might be associated with a larger capacity to sustain that exercise intensity. O(2)SC reached 274.11 +/- 152.83 l/min and was correlated with TLim (r = 0.54), increased ventilation in TLim test (r = 0.52) and energy cost of the respiratory muscles (r = 0.51), for p < 0.05. These data suggest that O(2)SC was also observed in the swimming pool, in high level swimmers performing at vVO(2)max, and that higher TLim seems to correspond to higher expected O(2)SC amplitude. These findings seem to bring new data with application in middle distance swimming.

  12. Back in the Classroom.

    ERIC Educational Resources Information Center

    Elliott, Tomm J.

    1993-01-01

    Describes a former superintendent's disconcerting swim in the teacher candidate pool while trying to find a teaching position without "pulling strings." After landing a job teaching 36 fifth graders, he soon realized that espousing methodologies is very different from actually doing them. Allowing students more responsibility for their learning…

  13. Operating experiences with rotary air-to-air heat exchangers: hospitals, schools, nursing homes, swimming pools

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pearson, R.J.

    1976-01-01

    Systems utilizing rotary air-to-air heat exchangers are discussed. Basic considerations of use (fresh air requirements, system configurations, cost considerations), typical system layout/design considerations, and operating observations by engineers, staff and maintenance personnel are described.

  14. 16 CFR 1207.6-1207.8 - [Reserved

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false [Reserved] 1207.6-1207.8 Section 1207.6-1207.8 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION CONSUMER PRODUCT SAFETY ACT REGULATIONS SAFETY STANDARD FOR SWIMMING POOL SLIDES §§ 1207.6-1207.8 [Reserved] ...

  15. 40 CFR 158.2201 - Antimicrobial use patterns.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    .... (10) Wood preservatives. (11) Swimming pools. (12) Aquatic areas. (b) Use site index. The Pesticide Use Site Index for Antimicrobial Pesticides is a comprehensive list of specific antimicrobial use sites. The Index associates antimicrobial use sites with one or more of the 12 antimicrobial use...

  16. 40 CFR 158.2201 - Antimicrobial use patterns.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    .... (10) Wood preservatives. (11) Swimming pools. (12) Aquatic areas. (b) Use site index. The Pesticide Use Site Index for Antimicrobial Pesticides is a comprehensive list of specific antimicrobial use sites. The Index associates antimicrobial use sites with one or more of the 12 antimicrobial use...

  17. 16 CFR 1207.9 - Product certification.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Product certification. 1207.9 Section 1207.9 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION CONSUMER PRODUCT SAFETY ACT REGULATIONS SAFETY STANDARD FOR SWIMMING POOL SLIDES § 1207.9 Product certification. (a) Certification shall be in accordance...

  18. Prior Individual Training and Self-Organized Queuing during Group Emergency Escape of Mice from Water Pool

    PubMed Central

    Saloma, Caesar; Perez, Gay Jane; Gavile, Catherine Ann; Ick-Joson, Jacqueline Judith; Palmes-Saloma, Cynthia

    2015-01-01

    We study the impact of prior individual training during group emergency evacuation using mice that escape from an enclosed water pool to a dry platform via any of two possible exits. Experimenting with mice avoids serious ethical and legal issues that arise when dealing with unwitting human participants while minimizing concerns regarding the reliability of results obtained from simulated experiments using ‘actors’. First, mice were trained separately and their individual escape times measured over several trials. Mice learned quickly to swim towards an exit–they achieved their fastest escape times within the first four trials. The trained mice were then placed together in the pool and allowed to escape. No two mice were permitted in the pool beforehand and only one could pass through an exit opening at any given time. At first trial, groups of trained mice escaped seven and five times faster than their corresponding control groups of untrained mice at pool occupancy rate ρ of 11.9% and 4%, respectively. Faster evacuation happened because trained mice: (a) had better recognition of the available pool space and took shorter escape routes to an exit, (b) were less likely to form arches that blocked an exit opening, and (c) utilized the two exits efficiently without preference. Trained groups achieved continuous egress without an apparent leader-coordinator (self-organized queuing)—a collective behavior not experienced during individual training. Queuing was unobserved in untrained groups where mice were prone to wall seeking, aimless swimming and/or blind copying that produced circuitous escape routes, biased exit use and clogging. The experiments also reveal that faster and less costly group training at ρ = 4%, yielded an average individual escape time that is comparable with individualized training. However, group training in a more crowded pool (ρ = 11.9%) produced a longer average individual escape time. PMID:25693170

  19. The distribution and public health consequences of releases of chemicals intended for pool use in 17 states, 2001-2009.

    PubMed

    Anderson, Ayana R; Welles, Wanda Lizak; Drew, James; Orr, Maureen F

    2014-05-01

    To keep swimming pool water clean and clear, consumers purchase, transport, store, use, and dispose of large amounts of potentially hazardous chemicals. Data about incidents due to the use of these chemicals and the resultant public health impacts are limited. The authors analyzed pool chemical release data from 17 states that participated in the Agency for Toxic Substances and Disease Registry's chemical event surveillance system during 2001-2009. In 400 pool chemical incidents, 60% resulted in injuries. Of the 732 injured persons, 67% were members of the public and 50% were under 18 years old. Incidents occurred most frequently in private residences (39%), but incidents with the most injured persons (34%) occurred at recreational facilities. Human error (71.9%) was the most frequent primary contributing factor, followed by equipment failure (22.8%). Interventions designed to mitigate the public health impact associated with pool chemical releases should target both private pool owners and public pool operators.

  20. Unintentional drownings among New York State residents, 1988-1994.

    PubMed Central

    Browne, Marilyn L.; Lewis-Michl, Elizabeth L.; Stark, Alice D.

    2003-01-01

    OBJECTIVE: This study examines situations in which drownings occur (environmental risk factors) and the victims' personal risk factors (age, gender, use of personal flotation device, medical condition, alcohol or drug use) to provide guidance for future drowning prevention efforts. METHODS: The authors investigated 883 non-bathtub drownings among New York State residents for the years 1988 to 1994 using medical examiner, coroner, police, and/or hospital records in addition to death certificate data. RESULTS: Males, children ages 0-4 years, and African American males ages 5-14 years residing in New York State outside New York City experienced the highest rates of drowning. The majority of drownings occurred in a natural body of water for all age groups, with the exception of children ages 0-4 years. Most drownings among children ages 0-4 years occurred in residential swimming pools. The child usually gained access to the pool via inadequate fencing, an open or ineffective gate, or a ladder (to an above-ground pool) left in the "down" position. Less than 10% of victims of watercraft-related drownings were wearing personal flotation devices. Blood alcohol concentration (BAC) tests were positive for 44% of 250 persons 15 years of age and older for whom valid toxicology results were provided; 30% had BACs of 100 mg/dl or more. CONCLUSIONS: Suggested prevention efforts include stricter enforcement of fencing requirements for residential swimming pools and drowning prevention education stressing personal flotation device use while boating and the danger of mixing alcohol and water-related activities. PMID:12941857

  1. Saving Energy. Managing School Facilities, Guide 3.

    ERIC Educational Resources Information Center

    Department for Education and Employment, London (England). Architects and Building Branch.

    This guide offers information on how schools can implement an energy saving action plan to reduce their energy costs. Various low-cost energy-saving measures are recommended covering heating levels and heating systems, electricity demand reduction and lighting, ventilation, hot water usage, and swimming pool energy management. Additional…

  2. Public Swimming Pools

    Science.gov Websites

    State Agencies | Online Services Forms Rules Ohio Public Health Advisory Board (OPHAB) Draft Pending Final Referenced Material Local Health Depts Find My Local Health Department What Do LHDs Do ? About Us About ODH ODH Locations News Reports Online Services What is Public Health? Employment

  3. U.S. EPA, Pesticide Product Label, PAXCIDE - SWIMMING POOL ALGEACIDE AND LOCKER ROOM DISINFECTANT, 04/08/1963

    EPA Pesticide Factsheets

    2011-04-14

    , , } , f 1 I t .. , , .L,- I- • • J. , ~ , , c. jll f' \\ .", _ J. oJ , \\ I'L' . ., UL . .i oel - , ...i. j~.lL[: ',1'\\,.: _ .. \\ .. l ,I \\ p' ~-; -L ,L ., :""i _ ..... t '--, , _ "\\ . l~i- ~.L...r· , , . ...

  4. 36 CFR 28.10 - Permitted and prohibited uses.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... natural resources of the Seashore, on any lands, whether publicly or privately-held, which lie below mean... a building, bulkhead, pile, septic system, revetment, deck, swimming pool, or other structure or man... education, and natural resource protection uses and facilities consistent with the uses and facilities...

  5. The Camp Caretaker: A Hidden Treasure.

    ERIC Educational Resources Information Center

    Ezersky, Eugene M.

    1996-01-01

    At a round-table discussion, five camp caretakers identified common camp maintenance problems. Snow loads, wooden floors, storage of lake equipment, removal of grass cuttings and leaves, local suppliers, vandalism and trespassing, swimming pools, assigning work, use of outside contractors, decisions to replace or repair, job satisfaction, and…

  6. 77 FR 16163 - Nondiscrimination on the Basis of Disability by Public Accommodations and in Commercial...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-20

    ...; Swimming Pools AGENCY: Civil Rights Division, Department of Justice. ACTION: Final rule. SUMMARY: By this.... FOR FURTHER INFORMATION CONTACT: Allison Nichol, Chief, Disability Rights Section, Civil Rights... Rights Division published a technical assistance document entitled ``ADA 2010 Revised Requirements...

  7. The Pimlico Chemistry Trail.

    ERIC Educational Resources Information Center

    Borrows, Peter

    1984-01-01

    Describes a chemistry "trail" (similar to a nature trail) which focuses on chemical phenomena in the environment. The trail includes 20 stops in and around a local school. Types of phenomena examined include building materials, air pollution, corrosion of metals, swimming pools, and others. Additional activities are also suggested. (DH)

  8. The Sanitarian--His Services to the Community

    ERIC Educational Resources Information Center

    Schoonover, Robert A., Ed.

    1973-01-01

    Sanitarians work to protect the community from various disease agents which may be present in the environment. They are responsible, among other tasks, for testing drinking water, restaurant foods, public swimming pools, and store products thought to be dangerous, for mosquito control and for rabies control. (KP)

  9. A bill to ensure the equitable treatment of swimming pool enclosures outside of hurricane season under the National Flood Insurance Program.

    THOMAS, 112th Congress

    Sen. Graham, Lindsey [R-SC

    2011-05-23

    Senate - 05/23/2011 Read twice and referred to the Committee on Banking, Housing, and Urban Affairs. (All Actions) Tracker: This bill has the status IntroducedHere are the steps for Status of Legislation:

  10. Water: The Ideal Early Learning Environment

    ERIC Educational Resources Information Center

    Grosse, Susan J.

    2008-01-01

    Bathtubs and swimming pools provide the ideal learning environment for people with special needs. For young preschool children, the activities that take place through water can help them develop physical fitness, facilitate motor development, reinforce perceptual-motor ability, encourage social development, and enhance self-esteem and confidence.…

  11. Because You Care For Kids...

    ERIC Educational Resources Information Center

    Consumer Product Safety Commission, Washington, DC.

    This booklet was developed by the U.S. Consumer Product Safety Commission (CPSC) to acquaint adults with products which research has shown to be hazardous to children. The booklet includes discussions of bicycles, toys, playground equipment, flammable fabrics, poisons, swimming pools, fireworks, and household products. Each discussion includes a…

  12. WARM SPRINGS CREEK GEOTHERMAL STUDY, BLAIN COUNTY IDAHO, 1987

    EPA Science Inventory

    In the Warm Springs Creek drainage near Ketchum, Idaho (17040219), a leaking pipeline coveys geothermal water through the valley to heat nearby homes as well as to supply a resorts swimming pool. Several domestic wells in close proximity to this line have exhibited increasing fl...

  13. LPT. EBOR (TAN646) interior, installing reactor in STF pool ("vault"). ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    LPT. EBOR (TAN-646) interior, installing reactor in STF pool ("vault"). Pressure vessel shows core barrel and outlet nozzle (next to man below) to inner duct weld, which is prepared and in position for stress relieving. Camera facing southeast. Photographer: Comiskey. Date: January 20, 1965. INEEL negative no. 65-239 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID

  14. Multi-age-grouping paradigm for young swimmers.

    PubMed

    Kojima, Kosuke; Jamison, Paul L; Stager, Joel M

    2012-01-01

    The purpose of this study was to examine the adequacy of "multi-age" classification systems in youth sports with a specific focus on the unisex multi-age-groupings used by USA Swimming. In addition, we offer an analytical rationale for the multi-age-groupings and potential alternatives. We examined the top 100 US swim performances for three years (2005, 2006, and 2007) for girls and boys in 15 age-groups (7 to 20 years and a singular group of 21 years and older). Data for each age and sex were pooled over the three years and means were calculated for each of seven competitive swim events. Swim times differed among each age up to the 14-year age-group in girls (F (14,30885) = 183.9, P < 0.01, Cohen's d = 1.19-3.72, large effect) and 16-year age-group in boys (F (14,30885) = 308.7, P < 0.01, Cohen's d = 0.81-3.64, large effect) for all events. Age-related differences in swim times continued later in boys than girls likely due to differences between the sexes in timing of growth and maturation. Because of the differences in swim performance in contemporary multi-age-groups, stratifying swimmers by a single age is the best means to ensure competitive fairness and equality, although there is no rationale for swimmers under the age of 8 years to compete in separate unisex competitive groups.

  15. A PILOT STUDY TO DETERMINE THE WATER VOLUME INJESTED BY RECREATIONAL SWIMMERS

    EPA Science Inventory

    The volume of water ingested by recreational swimmers is unknown. Previous estimates by a number of investigators range from 10mL to 100mL. These estimates, however, are unsupported by empirical data. Many outdoor swimming pools are disinfected using cyanuric acid stabilized c...

  16. Air Structures. Educational Facilities Review Series Number 23.

    ERIC Educational Resources Information Center

    Finne, Mary Lou

    Air structures can be erected quickly, cover large areas, cost substantially less than conventional buildings, and use less natural resources. Air structures are economically utilized for many facilities, such as athletic fields, swimming pools, high schools, day care centers, and college campuses. The literature on air structures covered in this…

  17. Presentations for Parents, 1974-75.

    ERIC Educational Resources Information Center

    Teske, Jeanne Hughes

    All but one of the articles contained in the book were presented, either verbatim or in expanded form, at a series of Parent Workshops conducted by the Mountain Plains Regional Center for Services to Deaf-Blind Children. Titles and authors include "Parents Are People" (J. Teske), "Swimming Pool Activities for Deaf-Blind…

  18. STABLE ASSOCIATION COMPLEX ELECTROSPRAY MASS SPECTROMETRY FOR THE DETERMINATION OF CYANURIC ACID

    EPA Science Inventory

    Cyanuric acid is a suspected gastrointestinal or liver toxicant in humans, and its long term effects on ecosystems are unknown. Cyanuric acid enters the environment in several ways. It is used as a chlorine stablilizer for recreational swimming pool waters. Because of its inheren...

  19. PLANNING THE INDOOR PHYSICAL EDUCATION FACILITIES.

    ERIC Educational Resources Information Center

    HASE, GERALD J.; HICK, BASIL L.

    THIS PAMPHLET IS DESIGNED TO HELP ARCHITECTS AND LOCAL SCHOOL OFFICIALS IN THE PREPARATION OF PLANS FOR PHYSICAL EDUCATION FACILITIES IN NEW AND EXISTING BUILDINGS. FACILITIES MENTIONED INCLUDE--(1) GYMNASIUM, (2) SWIMMING POOL, (3) SMALL GROUP ACTIVITY ROOM, (4) DRESSING AND SHOWERING ROOMS, (5) TEAM ROOM, (6) EQUIPMENT DRYING ROOM, (7) LAUNDRY…

  20. Keeping recreational water facilities safe.

    PubMed

    Farquhar, Doug

    2015-06-01

    (1) Outbreaks of diseases associated with aquatic venues have nearly quadrupled—to more than 40 per year. (2) The Cryptosporidium (Crypto) germ is the leading cause of diarrheal outbreaks related to swimming pools. (3) A national voluntary effort is underway to reduce the number of illnesses and injuries from recreational water facilities.

  1. This School Is for Kids and Community.

    ERIC Educational Resources Information Center

    American School Board Journal, 1982

    1982-01-01

    In Avon (Indiana), a community lacking public buildings, a middle school was built with community uses in mind. The swimming pool, gymnasium, and commons area can be blocked off for community use by using floor-to-ceiling gates. The school's heating, ventilating, and air conditioning systems are also energy-efficient. (Author/MLF)

  2. Genotoxicity of Swimming Pool Water and Carcinogenicity of Drinking Water

    EPA Science Inventory

    Among the 11 disinfection by-products (DBPs) in drinking water that are regulated by the U.S. EPA, (a) 2 DBPs (chloroaceticacid and chlorite) are not carcinogenic-in either of2 species; (b) chlorite is not carcinogenic in 3 rodent assays and has never been tested for genotoxicity...

  3. Genotoxicity of Swimming Pool Water and Carcinogenicity of Drinking Water**

    EPA Science Inventory

    Among the 11 disinfection by-products (DBPs) in drinking water that are regulated by the U.S. EPA, (a) 2 DBPs (chloroaceticacid and chlorite) are not carcinogenic-in either of2 species; (b) chlorite is not carcinogenic in 3 rodent assays and has never been tested for genotoxicity...

  4. 26 CFR 1.23-3 - Special rules.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... expenditures on solar energy property for B's principal residence. Approximately 60 percent of the use of the solar energy property will be for heating B's swimming pool; the other 40 percent will be for heating... use of B's solar energy property is considered used for personal residential purposes. Therefore, only...

  5. 26 CFR 1.23-3 - Special rules.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... expenditures on solar energy property for B's principal residence. Approximately 60 percent of the use of the solar energy property will be for heating B's swimming pool; the other 40 percent will be for heating... use of B's solar energy property is considered used for personal residential purposes. Therefore, only...

  6. 26 CFR 1.23-3 - Special rules.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... expenditures on solar energy property for B's principal residence. Approximately 60 percent of the use of the solar energy property will be for heating B's swimming pool; the other 40 percent will be for heating... use of B's solar energy property is considered used for personal residential purposes. Therefore, only...

  7. 16 CFR 1207.10 - Handling, storage, and marking.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 16 Commercial Practices 2 2011-01-01 2011-01-01 false Handling, storage, and marking. 1207.10... REGULATIONS SAFETY STANDARD FOR SWIMMING POOL SLIDES § 1207.10 Handling, storage, and marking. (a) Marking... identification of the manufacturer. (b) Shipping, handling, and storage. The slide shall be designed, constructed...

  8. 16 CFR 1207.10 - Handling, storage, and marking.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 16 Commercial Practices 2 2014-01-01 2014-01-01 false Handling, storage, and marking. 1207.10... REGULATIONS SAFETY STANDARD FOR SWIMMING POOL SLIDES § 1207.10 Handling, storage, and marking. (a) Marking... identification of the manufacturer. (b) Shipping, handling, and storage. The slide shall be designed, constructed...

  9. 16 CFR 1207.10 - Handling, storage, and marking.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 16 Commercial Practices 2 2012-01-01 2012-01-01 false Handling, storage, and marking. 1207.10... REGULATIONS SAFETY STANDARD FOR SWIMMING POOL SLIDES § 1207.10 Handling, storage, and marking. (a) Marking... identification of the manufacturer. (b) Shipping, handling, and storage. The slide shall be designed, constructed...

  10. 16 CFR 1207.10 - Handling, storage, and marking.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Handling, storage, and marking. 1207.10... REGULATIONS SAFETY STANDARD FOR SWIMMING POOL SLIDES § 1207.10 Handling, storage, and marking. (a) Marking... identification of the manufacturer. (b) Shipping, handling, and storage. The slide shall be designed, constructed...

  11. Physical and energy requirements of competitive swimming events.

    PubMed

    Pyne, David B; Sharp, Rick L

    2014-08-01

    The aquatic sports competitions held during the summer Olympic Games include diving, open-water swimming, pool swimming, synchronized swimming, and water polo. Elite-level performance in each of these sports requires rigorous training and practice to develop the appropriate physiological, biomechanical, artistic, and strategic capabilities specific to each sport. Consequently, the daily training plans of these athletes are quite varied both between and within the sports. Common to all aquatic athletes, however, is that daily training and preparation consumes several hours and involves frequent periods of high-intensity exertion. Nutritional support for this high-level training is a critical element of the preparation of these athletes to ensure the energy and nutrient demands of the training and competition are met. In this article, we introduce the fundamental physical requirements of these sports and specifically explore the energetics of human locomotion in water. Subsequent articles in this issue explore the specific nutritional requirements of each aquatic sport. We hope that such exploration will provide a foundation for future investigation of the roles of optimal nutrition in optimizing performance in the aquatic sports.

  12. Investigation of some disinfection chemicals and water quality parameters in swimming pools in the city center and districts of Canakkale, Turkey.

    PubMed

    Uysal, Tolga; Yilmaz, Selehattin; Turkoglu, Muhammet; Sadikoglu, Murat

    2017-07-01

    In this study, the variations in concentrations of some disinfection chemicals such as cyanuric acid (CyA), free chlorine (FC), and residual chlorine (RC), which affect human health, were investigated in the water of swimming pools. In addition, quality parameters such as temperature, pH, and total alkalinity (TA) in 44 swimming pools located in the city center and districts of Canakkale, Turkey, were examined in the summer period. While FC and RC amounts were analyzed using tablet tests with N-N-diethyl phenylenediamine (DPD 1) and potassium iodine (DPD 3) using the colorimetric method in the comparator, TA and CyA levels were measured with a photometric method. Temperature and pH were measured using YSI 556 MPS. Levels of CyA, FC, RC, pH, temperature, and TA varied between 0.00 and 725.0 mg L -1 (108.0 ± 111.4 mg L -1 ), 0.00 and 5.00 mg L -1 (1.60 ± 0.962 mg L -1 ), 0 and 0.55 mg L -1 (0.087 ± 0.059), 6.40 and 8.20 mg L -1 (7.30 ± 0.038 mg L -1 ), 22.0 and 32.0 °C (27.6 ± 1.45 °C), and 0.00 and 391.0 mg L -1 (129.3 ± 89.0), respectively. The findings were compared to standard limit values of the Ministry of Health of the Turkish Republic and other countries. Not only maximum concentrations of CyA but also the average concentrations exceeded the standard limit values of different countries in July and August with high tourism activity in Turkey. Although there is no problem in view of average values of other quality parameters, there are some problems in view of the maximum values in pool waters compared to standard limit values.

  13. Solar energy system demonstration project at Wilmington Swim School, New Castle, Delaware

    NASA Astrophysics Data System (ADS)

    1980-07-01

    A solar energy system located at the Wilmington Swim School, New Castle, Delaware is described. The system was designed for a 40 percent heating and a 30 percent hot water solar contribution serving the heat loads in the following order: space heat - new addition, domestic water - entire facility, and pool heating - entire facility. On a cost basis for 2920 hours of operation, the heat reclaimed would cost $969.66 annually if provided by gas at 3.79 per million Btu's. At 5.5 centers per kwh, heat recovery costs of $481.80 percent a net savings of $487.86 annually.

  14. Solar energy system demonstration project at Wilmington Swim School, New Castle, Delaware

    NASA Technical Reports Server (NTRS)

    1980-01-01

    A solar energy system located at the Wilmington Swim School, New Castle, Delaware is described. The system was designed for a 40 percent heating and a 30 percent hot water solar contribution serving the heat loads in the following order: space heat - new addition, domestic water - entire facility, and pool heating - entire facility. On a cost basis for 2920 hours of operation, the heat reclaimed would cost $969.66 annually if provided by gas at 3.79 per million Btu's. At 5.5 centers per kwh, heat recovery costs of $481.80 percent a net savings of $487.86 annually.

  15. Conceptual design of BNCT facility based on the TRR medical room

    NASA Astrophysics Data System (ADS)

    Golshanian, M.; Rajabi, A. A.; Kasesaz, Y.

    2017-10-01

    This paper presents a conceptual design of the Boron Neutron Capture Therapy (BNCT) facility based on the medical room of Tehran Research Reactor (TRR). The medical room is located behind the east wall of the reactor pool. The designed beam line is an in-pool Beam Shaping Assembly (BSA) which is considered between the reactor core and the medical room wall. The final designed BSA can provide 2.96× 109 n/cm2ṡs epithermal neutron flux at the irradiation position with acceptable beam contamination to use as a clinical BNCT.

  16. Development work for a borax internal core-catcher for a gas-cooled fast reactor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Donne, M.D.; Dorner, S.; Schumacher, G.

    1978-07-01

    Preliminary thermal calculations show that a corecatcher, which is able to cope with the complete meltdown of the core and blankets of a 1000-MW(electric) gas-cooled fast reactor, appears to be feasible. This core-catcher is based on borax (Na/sub 2/B/sub 4/O/sub 7/) dissolving the oxide fuel and the fission products occurring in oxide form. The borax is contained in steel boxes forming a 2.2-m-thick slab on the base of the reactor cavity inside the prestressed concrete reactor vessel (PCRV), just underneath the reactor core. After a complete meltdown accident, the fission products, in oxide form, are dispersed in the pool formedmore » by the liquid borax. The metallic fission products are contained in the steel lying below the borax pool and in contact with the water-cooled PCRV liner. The volumetric power density of the molten core is conveniently reduced as it is dissolved in the borax, and the resulting heat fluxes at the borders of the pool can be safely carried away through the PCRV liner and its water cooling system.« less

  17. Swimming kinematics of the Florida manatee (Trichechus manatus latirostris): hydrodynamic analysis of an undulatory mammalian swimmer.

    PubMed

    Kojeszewski, Tricia; Fish, Frank E

    2007-07-01

    The submerged swimming of the Florida manatee (Trichechus manatus latirostris), a subspecies of the West Indian manatee, was studied by filming individuals as they swam rectilinearly in a large pool at several rehabilitation centers. The swimming was analyzed using videography to detail the kinematics in conjunction with a hydromechanical model to determine the power output (P(t)) and propulsive efficiency (eta(p)). Manatees swam at velocities of 0.06-1.14 m s(-1). Locomotion was accomplished by undulation of the body and caudal fluke. Undulatory locomotion is a rapid and relatively high-powered propulsive mode involved in cruising and migrating by a variety of swimmers. Manatees displayed an undulatory swimming mode by passing a dorso-ventrally oriented traveling wave posteriorly along the body. The propulsive wave traveled at a higher velocity than the forward velocity of the animal. The frequency of the propulsive cycle (f) increased linearly with increasing swimming velocity (U). Amplitude at the tip of the caudal fluke (A) remained constant with respect to U and was 22% of body length. P(t) increased curvilinearly with U. The mean eta(p), expressing the relationship of the thrust power generated by the paddle-shaped caudal fluke to the total mechanical power, was 0.73. The maximum eta(p) was 0.82 at 0.95 m s(-1). Despite use of a primitive undulatory swimming mode and paddle-like fluke for propulsion, the manatee is capable of swimming with a high efficiency but lower power outputs compared with the oscillatory movements of the high-aspect ratio flukes of cetaceans. The swimming performance of the manatee is in accordance with its habits as an aquatic grazer that seasonally migrates over extended distances.

  18. Effect of Beetroot Juice Supplementation on Aerobic Response during Swimming

    PubMed Central

    Pinna, Marco; Roberto, Silvana; Milia, Raffaele; Marongiu, Elisabetta; Olla, Sergio; Loi, Andrea; Migliaccio, Gian Mario; Padulo, Johnny; Orlandi, Carmine; Tocco, Filippo; Concu, Alberto; Crisafulli, Antonio

    2014-01-01

    The beneficial effects of beetroot juice supplementation (BJS) have been tested during cycling, walking, and running. The purpose of the present study was to investigate whether BJS can also improve performance in swimmers. Fourteen moderately trained male master swimmers were recruited and underwent two incremental swimming tests randomly assigned in a pool during which workload, oxygen uptake (VO2), carbon dioxide production (VCO2), pulmonary ventilation (VE), and aerobic energy cost (AEC) of swimming were measured. One was a control swimming test (CSW) and the other a swimming test after six days of BJS (0.5l/day organic beetroot juice containing about 5.5 mmol of NO3−). Results show that workload at anaerobic threshold was significantly increased by BJS as compared to the CSW test (6.3 ± 1 and 6.7 ± 1.1 kg during the CSW and the BJS test respectively). Moreover, AEC was significantly reduced during the BJS test (1.9 ± 0.5 during the SW test vs. 1.7 ± 0.3 kcal·kg−1·h−1 during the BJS test). The other variables lacked a statistically significant effect with BJS. The present investigation provides evidence that BJS positively affects performance of swimmers as it reduces the AEC and increases the workload at anaerobic threshold. PMID:24481133

  19. Effect of beetroot juice supplementation on aerobic response during swimming.

    PubMed

    Pinna, Marco; Roberto, Silvana; Milia, Raffaele; Marongiu, Elisabetta; Olla, Sergio; Loi, Andrea; Migliaccio, Gian Mario; Padulo, Johnny; Orlandi, Carmine; Tocco, Filippo; Concu, Alberto; Crisafulli, Antonio

    2014-01-29

    The beneficial effects of beetroot juice supplementation (BJS) have been tested during cycling, walking, and running. The purpose of the present study was to investigate whether BJS can also improve performance in swimmers. Fourteen moderately trained male master swimmers were recruited and underwent two incremental swimming tests randomly assigned in a pool during which workload, oxygen uptake (VO₂), carbon dioxide production (VCO₂), pulmonary ventilation (VE), and aerobic energy cost (AEC) of swimming were measured. One was a control swimming test (CSW) and the other a swimming test after six days of BJS (0.5 l/day organic beetroot juice containing about 5.5 mmol of NO₃⁻). Results show that workload at anaerobic threshold was significantly increased by BJS as compared to the CSW test (6.3 ± 1 and 6.7 ± 1.1 kg during the CSW and the BJS test respectively). Moreover, AEC was significantly reduced during the BJS test (1.9 ± 0.5 during the SW test vs. 1.7 ± 0.3 kcal·kg⁻¹1·h⁻¹ during the BJS test). The other variables lacked a statistically significant effect with BJS. The present investigation provides evidence that BJS positively affects performance of swimmers as it reduces the AEC and increases the workload at anaerobic threshold.

  20. Increase in swimming endurance capacity of mice by capsaicin-induced adrenal catecholamine secretion.

    PubMed

    Kim, K M; Kawada, T; Ishihara, K; Inoue, K; Fushiki, T

    1997-10-01

    Increase in endurance swimming capacity caused by capsaicin (CAP), a pungent component of red pepper, -induced increase of fat metabolism in mice was investigated using an adjustable-current water pool. The mice administered CAP via a stomach tube, showed longer swimming time until exhaustion than the control group of mice, in a dose-dependent manner. The maximal effect was observed at a dose of 10 mg/kg while more than 15 mg/kg had no effect. The increase of endurance was observed only when CAP was administered two hours before swimming. After the administration of CAP, the serum glucose concentration rapidly increased and then decreased within 60 min, while the concentration of serum-free fatty acids gradually increased through 3 hours. The residual glycogen concentration of the gastrocnemius muscle after 30 min of swimming was significantly higher in the CAP-administered mice than in control mice, suggesting that use of the serum free fatty acids spared muscle glycogen consumption. The serum adrenaline concentration significantly increased with twin peaks at 30 min and two hours after administration of CAP. An experiment using adrenalectomized mice was done to confirm that the effect of CAP is due to increased energy metabolism through the secretion of adrenaline from the adrenal gland. The swimming endurance capacity of the adrenalectomized mice was not increased by CAP administration, although adrenaline injection induced a 58% increase in the endurance time. These results suggest that the increase of swimming endurance induced by CAP in mice is caused by an increase in fatty acid utilization due to CAP-induced adrenal catecholamine secretion.

  1. Impact of swimming on chronic suppurative otitis media in Aboriginal children: a randomised controlled trial.

    PubMed

    Stephen, Anna T N; Leach, Amanda J; Morris, Peter S

    2013-07-08

    To measure the impact of 4 weeks of daily swimming on rates of ear discharge among Aboriginal children with a tympanic membrane perforation (TMP) and on the microbiology of the nasopharynx and middle ear. A randomised controlled trial involving 89 Aboriginal children (aged 5-12 2013s) with a TMP, conducted in two remote Northern Territory Aboriginal communities from August to December 2009. 4 school weeks of daily swimming lessons (45 minutes) in a chlorinated pool. Proportions of children with ear discharge and respiratory and opportunistic bacteria in the nasopharynx and middle ear. Of 89 children randomly assigned to the swimming or non-swimming groups, 58 (26/41 swimmers and 32/48 non-swimmers) had ear discharge at baseline. After 4 weeks, 24 of 41 swimmers had ear discharge compared with 32 of 48 non-swimmers (risk difference, - 8% (95% CI, - 28% to 12%). There were no statistically significant changes in the microbiology of the nasopharynx or middle ear in swimmers or non-swimmers. Streptococcus pneumoniae and non-typeable Haemophilus influenzae were the dominant organisms cultured from the nasopharynx, and H. influenzae, Staphylococcus aureus and Pseudomonas aeruginosa were the dominant organisms in the middle ear. Swimming lessons for Aboriginal children in remote communities should be supported, but it is unlikely that they will substantially reduce rates of chronic suppurative otitis media and associated bacteria in the nasopharynx and middle ear. However, swimming was not associated with increased risk of ear discharge and we found no reason to discourage it. Australian New Zealand Clinical Trials Registry ACTRN12613000634774.

  2. Secondary formation of disinfection by-products by UV treatment of swimming pool water.

    PubMed

    Spiliotopoulou, Aikaterini; Hansen, Kamilla M S; Andersen, Henrik R

    2015-07-01

    Formation of disinfection by-products (DBPs) during experimental UV treatment of pool water has previously been reported with little concurrence between laboratory studies, field studies and research groups. In the current study, changes in concentration of seven out of eleven investigated volatile DBPs were observed in experiments using medium pressure UV treatment, with and without chlorine and after post-UV chlorination. Results showed that post-UV chlorine consumption increased, dose-dependently, with UV treatment dose. A clear absence of trihalomethane formation by UV and UV with chlorine was observed, while small yet statistically significant increases in dichloroacetonitrile and dichloropropanone concentrations were detected. Results indicate that post-UV chlorination clearly induced secondary formation of several DBPs. However, the formation of total trihalomethanes was no greater than what could be replicated by performing the DBP formation assay with higher chlorine concentrations to simulate extended chlorination. Post-UV chlorination of water from a swimming pool that continuously uses UV treatment to control combined chlorine could not induce secondary formation for most DBPs. Concurrence for induction of trihalomethanes was identified between post-UV chlorination treatments and simulated extended chlorination time treatment. Trihalomethanes could not be induced by UV treatment of water from a continuously UV treated pool. This indicates that literature reports of experimentally induced trihalomethane formation by UV may be a result of kinetic increase in formation by UV. However, this does not imply that higher trihalomethane concentrations would occur in pools that apply continuous UV treatment. The bromine fraction of halogens in formed trihalomethanes increased with UV dose. This indicates that UV removes bromine atoms from larger molecules that participate in trihalomethane production during post-UV chlorination. Additionally, no significant effect on DBP formation was observed due to photo-inducible radical forming molecules NO3- (potentially present in high concentrations in pool water) and H2O2 (added as part of commercially employed DBP reducing practices). Copyright © 2015 Elsevier B.V. All rights reserved.

  3. The effect of cold water endurance swimming on core temperature in aspiring English Channel swimmers.

    PubMed

    Diversi, Tara; Franks-Kardum, Vanessa; Climstein, Mike

    2016-01-01

    The purpose of this study was to determine if cold water swimmers (CWS) developed hypothermia over a 6-h cold water endurance swim and whether body composition, stroke rate (SR) or personal characteristics correlated with core temperature (TC) change. Nine experienced male and female CWS who were aspiring English Channel (EC) swimmers volunteered to participate. Subjects aimed to complete their 6-h EC qualifying swim (water 15-15.8 °C/air 15-25 °C) while researchers intermittently monitored TC and SR. Data obtained included anthropometry (height, mass, segmental body composition), training volume and EC completion. Of the nine swimmers who volunteered, all successfully completed their EC qualifying swim. Six CWS had complete data included in analysis. One CWS demonstrated hypothermia (34.8 °C) at 6-h. TC rate of decline was slower in the first 3 h (-0.06 °C/hr) compared to the last 3 h (-0.36 °C/hr) of the swim. Older age was significantly correlated to TC change (r = -0.901, p < 0.05) and SR change (r = -0.915, p < 0.05). Absolute and percentage body fat (BF) were not significantly associated with higher TC. Mean SR over the 6-h swim was 57.8 spm (range 48-73 spm), and a significant (p < 0.05) decline in SR was observed over the 6 h (-9.7 %). A strong, positive correlation was found between SR change between 3 and 6 h and TC over the 6 h (r = 0.840, p < 0.05) and TC from 3-6 h (r = 0.827, p < 0.05). Seven of the nine participants (77.8 %) in this study successfully completed the EC crossing. Successful EC swimmers swam in the pool and open water (OW); however, they swam significantly [t (7) = -2.433, p < 0.05] more kilometres (M = 19.09 km/wk ± 5.55) in OW than unsuccessful (M = 9 km/wk ± 1.41) EC swimmers. There was a significant relationship between EC crossing time and height (r = -0.817, p < 0.05), but no other variables and EC crossing time. Cold water endurance swim (CWES) of 6-h duration at 15-16 °C resulted in TC reduction in the majority of swimmers regardless of anthropometry. More research is required to determine why some CWS are able to maintain their TC throughout a CWES. Our results indicate that older swimmers are at greater risk of developing hypothermia, and that SR decline is an indicator of TC decline. Our results also suggest that OW swimming training combined with pool training is important for EC swim success.

  4. Method development and validation for simultaneous determination of IEA-R1 reactor’s pool water uranium and silicon content by ICP OES

    NASA Astrophysics Data System (ADS)

    Ulrich, J. C.; Guilhen, S. N.; Cotrim, M. E. B.; Pires, M. A. F.

    2018-03-01

    IPEN’s research reactor, IEA-R1, an open pool type research reactor moderated and cooled by light water. High quality water is a key factor in preventing the corrosion of the spent fuel stored in the pool. Leaching of radionuclides from the corroded fuel cladding may be prevented by an efficient water treatment and purification system. However, as a safety management policy, IPEN has adopted a water chemistry control which periodically monitors the levels of uranium (U) and silicon (Si) in the pool’s reactor, since IEA-R1 employs U3Si2-Al dispersion fuel. An analytical method was developed and validated for the determination of uranium and silicon by ICP OES. This work describes the validation process, in a context of quality assurance, including the parameters selectivity, linearity, quantification limit, precision and recovery.

  5. Seasonal and Cyclical Changes in Genetic Composition of the Marine Intertidal Rock Pool Copepod Tigriopus brevicornis.

    PubMed

    Van Wormhoudt, Alain

    2015-06-01

    Tigriopus brevicornis is a marine rock pool copepod widely distributed along Atlantic coasts. Due to the absence of a known dispersal mechanism by free swimming stages, exchanges between populations over long distances are questionable. In order to analyse the evolution of an isolated supralittoral rock pool population, sampling of the copepod was performed monthly during 1 year and compared to samplings over 5 years in the same rock pool, as well as from other rock pools. Using ITS1 analysis, cyclical changes in genetic composition were detected. Our results give clear indications concerning the segregation of the rock pool population and a lack of gene flow among outside populations. A network analysis shows the presence of several shared dominant haplotypes and also singletons differing by one mutation point. F(st) analyses indicate that the main changes occur in autumn and winter. The few analogies of ITS1 sequences with nearby populations may indicate that new migrants must re-colonise the pools from surrounding rock crevices in the intertidal habitat where they may have found a refuge after bad weather conditions.

  6. Solar for Your Present Home. San Francisco Bay Area Edition.

    ERIC Educational Resources Information Center

    Barnaby, Charles S.; And Others

    This publication provides information about present uses of solar energy for space, water, and swimming pool heating that are practical for the San Francisco Bay area. It attempts to provide interested persons with the information needed to make decisions regarding installations of solar heating systems. The point of view taken is that any…

  7. College and University Facilities Guide for Health, Physical Education, Recreation, and Athletics.

    ERIC Educational Resources Information Center

    American Association for Health, Physical Education, and Recreation, Washington, DC.

    This guide presents information concerned with the planning of areas and facilities for athletics, recreation, outdoor education, and physical and health education. Swimming pools, service areas, ice skating, field houses, arenas, and stadiums are among the many facilities which are considered. Included are many diagrams and sketches giving…

  8. 36 CFR 28.12 - Development standards.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... significant harm to the natural resources of the Seashore. (c) Minimum lot size is 4,000 square feet. A.../FEMA shown on Flood Insurance Rate Maps for Fire Island communities. (g) A swimming pool is an... hazards and/or detract from the natural or cultural scene. (j) A zoning authority shall have in place...

  9. Public Swimming Pools | Florida Department of Health

    Science.gov Websites

    Phone Numbers WIC Income Guidelines How WIC Works WIC Foods Food Vendors Health Care Providers Nutrition Materials What is WIC? WIC is a federally funded nutrition program for Women, Infants, and Children. WIC provides the following at no cost: healthy foods, nutrition education and counseling, breastfeeding support

  10. 40 CFR Appendix A to Subpart F of... - List of Qualified Energy Conservation Measures, Qualified Renewable Generation, and Measures...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... replacements • Customer located power generation based on photovoltaic, solar thermal, biomass, wind or geothermal resources • Swimming pool pump replacements • Gasket replacements • Maintenance/coil cleaning 1... photovoltaic, solar thermal, biomass, wind, and geothermal resources • Energy efficient office equipment...

  11. 40 CFR Appendix A to Subpart F of... - List of Qualified Energy Conservation Measures, Qualified Renewable Generation, and Measures...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... replacements • Customer located power generation based on photovoltaic, solar thermal, biomass, wind or geothermal resources • Swimming pool pump replacements • Gasket replacements • Maintenance/coil cleaning 1... photovoltaic, solar thermal, biomass, wind, and geothermal resources • Energy efficient office equipment...

  12. 40 CFR Appendix A to Subpart F of... - List of Qualified Energy Conservation Measures, Qualified Renewable Generation, and Measures...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... replacements • Customer located power generation based on photovoltaic, solar thermal, biomass, wind or geothermal resources • Swimming pool pump replacements • Gasket replacements • Maintenance/coil cleaning 1... photovoltaic, solar thermal, biomass, wind, and geothermal resources • Energy efficient office equipment...

  13. 40 CFR Appendix A to Subpart F of... - List of Qualified Energy Conservation Measures, Qualified Renewable Generation, and Measures...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... replacements • Customer located power generation based on photovoltaic, solar thermal, biomass, wind or geothermal resources • Swimming pool pump replacements • Gasket replacements • Maintenance/coil cleaning 1... photovoltaic, solar thermal, biomass, wind, and geothermal resources • Energy efficient office equipment...

  14. 40 CFR Appendix A to Subpart F of... - List of Qualified Energy Conservation Measures, Qualified Renewable Generation, and Measures...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... replacements • Customer located power generation based on photovoltaic, solar thermal, biomass, wind or geothermal resources • Swimming pool pump replacements • Gasket replacements • Maintenance/coil cleaning 1... photovoltaic, solar thermal, biomass, wind, and geothermal resources • Energy efficient office equipment...

  15. Geothermal Cogeneration: Iceland's Nesjavellir Power Plant

    ERIC Educational Resources Information Center

    Rosen, Edward M.

    2008-01-01

    Energy use in Iceland (population 283,000) is higher per capita than in any other country in the world. Some 53.2% of the energy is geothermal, which supplies electricity as well as heated water to swimming pools, fish farms, snow melting, greenhouses, and space heating. The Nesjavellir Power Plant is a major geothermal facility, supplying both…

  16. A Phase Odyssey

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nugent, K.A.; Paganin, D.; Gureyev, T.E.

    2009-01-06

    We are introduced to the effects of phase from the earliest days of our childhood, from the nursery rhyme above (or its less verbose for 'Twinkle, Twinkle Little Star') to the shimmer over a hot road and the network of bright lines at the bottom of a swimming pool. These are all manifestations of phase. And there are many more.

  17. 77 FR 40326 - Executive-Led Infrastructure Business Development Mission Statement November 11-17, 2012...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-07-09

    ... features and swimming pools, hotel and restaurant interiors, town planning/ master planning, green design... applicants will be evaluated on their ability to meet certain conditions and to best satisfy the selection...-one percent U.S. content. Selection Criteria for Participation Selection will be based on the...

  18. Inflatable Column Structure

    NASA Technical Reports Server (NTRS)

    Hedgepeth, J. M.

    1985-01-01

    Lightweight structural member easy to store. Billowing between circumferential loops of fiber inflated column becomes series of cells. Each fiber subjected to same tension along entire length (though tension is different in different fibers). Member is called "isotensoid" column. Serves as jack for automobiles or structures during repairs. Also used as support for temporary bleachers or swimming pools.

  19. 16 CFR § 1207.10 - Handling, storage, and marking.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 16 Commercial Practices 2 2013-01-01 2013-01-01 false Handling, storage, and marking. § 1207.10... REGULATIONS SAFETY STANDARD FOR SWIMMING POOL SLIDES § 1207.10 Handling, storage, and marking. (a) Marking... identification of the manufacturer. (b) Shipping, handling, and storage. The slide shall be designed, constructed...

  20. Potential phototoxicity of aged Al(OH)3-coated Ti02 nanoparticles in retinal pigment epithelial cells

    EPA Science Inventory

    Titanium dioxide (TiO2) nanoparticles (NPs) exposed to UVA radiation generate reactive oxygen species (ROS). As a component of sunscreen formulations, TiO2 NPs may be coated with Al(OH)3 to prevent ROS from causing oxidative damage to tissues. Simulated swimming pool water (SSPW)...

  1. 16 CFR § 1207.5 - Design.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... installed swimming pool slide shall be such that no structural failures of any component part shall cause failures of any other component part of the slide as described in the performance tests in paragraphs (d)(4... number and placement of such fasteners shall not cause a failure of the tread under the ladder loading...

  2. Swim drink study: a randomised controlled trial of during-exercise rehydration and swimming performance.

    PubMed

    Briars, Graham L; Gordon, Gillian Suzanne; Lawrence, Andrew; Turner, Andrew; Perry, Sharon; Pillbrow, Dan; Walston, Florence Einstein; Molyneux, Paul

    2017-01-01

    To determine whether during-exercise rehydration improves swimming performance and whether sports drink or water have differential effects on performance. Randomised controlled multiple crossover trial. A UK competitive swimming club. 19 club-level competitive swimmers, median age (range) 13 (11-17) years. Subjects were scheduled to drink ad libitum commercial isotonic sports drink (3.9 g sugars and 0.13 g salt per 100 mL) or water (three sessions each) or no drink (six sessions) in the course of twelve 75 min training sessions, each of which was followed by a 30 min test set of ten 100 m maximum-effort freestyle sprints each starting at 3 min intervals. Times for the middle 50 m of each sprint measured using electronic timing equipment in a Federation Internationale de Natation (FINA)-compliant six-lane 25 m competition swimming pool. Software-generated individual random session order in sealed envelopes. Analysis subset of eight sessions randomly selected by software after data collection completed. Participants blind to drink allocation until session start. In the analysis data set of 1118 swims, there was no significant difference between swim times for drinking and not drinking nor between drinking water or a sports drink. Mean (SEM) 50 m time for no-drink swims was 38.077 (0.128) s and 38.105 (0.131) s for drink swims, p=0.701. Mean 50 m times were 38.031 (0.184) s for drinking sports drink and 38.182 (0.186) s for drinking water, p=0.073. Times after not drinking were 0.027 s faster than after drinking (95% CI 0.186 s faster to 0.113 s slower). Times after drinking sports drink were 0.151 s faster than after water (95% CI 0.309 s faster to 0.002 s slower). Mean (SEM) dehydration from exercise was 0.42 (0.11)%. Drinking water or sports drink over 105 min of sustained effort swimming training does not improve swimming performance. ISRCTN: 49860006.

  3. Modifying the food supply at a community swimming pool: a case study.

    PubMed

    Lloyd, Beverley; Dumbrell, Susan

    2011-04-01

    We report on a process evaluation of a project that aimed to replace energy-dense, nutrient-poor (EDNP) items at a community swimming pool kiosk. The analytic framework was the Analysis Grid for Environments Linked to Obesity (ANGELO). To contribute to health promotion practice in recreational settings, the process evaluation sought to determine the extent to which project'controversies' modified project objectives and strategies. The case study method captured the project narrative. The primary data were interviews with key project participants, supplemented with project records and media articles.These were analysed thematically. The socio-cultural and political environments, particularly the capacity to exercise choice in relation to ENDP products, had considerable influence on the project. In the face of two controversies -"I thought everyone was signed up to it"and "We can't deny the kiddies their ice-cream" it was necessary for the project partners to modify the objectives and strategies and substantially change the target. The setting is highly responsive to both the micro and macro socio-cultural and political aspects of the environment.

  4. Pacing in Swimming: A Systematic Review.

    PubMed

    McGibbon, Katie E; Pyne, D B; Shephard, M E; Thompson, K G

    2018-03-20

    Pacing strategy, or how energy is distributed during exercise, can substantially impact athletic performance and is considered crucial for optimal performance in many sports. This is particularly true in swimming given the highly resistive properties of water and low mechanical efficiency of the swimming action. The aim of this systematic review was to determine the pacing strategies utilised by competitive swimmers in competition and their reproducibility, and to examine the impact of different pacing strategies on kinematic, metabolic and performance variables. This will provide valuable and practical information to coaches and sports science practitioners. The databases Web of Science, Scopus, SPORTDiscus and PubMed were searched for published articles up to 1 August 2017. A total of 23 studies examining pool-based swimming competitions or experimental trials in English-language and peer-reviewed journals were included in this review. In short- and middle-distance swimming events maintenance of swimming velocity is critical, whereas in long-distance events a low lap-to-lap variability and the ability to produce an end spurt in the final lap(s) are key. The most effective strategy in the individual medley (IM) is to conserve energy during the butterfly leg to optimise performance in subsequent legs. The pacing profiles of senior swimmers remain relatively stable irrespective of opponents, competition stage or type, and performance time. Implementing event-specific pacing strategies should benefit the performance of competitive swimmers. Given differences between swimmers, there is a need for greater individualisation when considering pacing strategy selection across distances and strokes.

  5. System and process for the production of syngas and fuel gasses

    DOEpatents

    Bingham, Dennis N.; Kllingler, Kerry M.; Turner, Terry D.; Wilding, Bruce M.; Benefiel, Bradley C.

    2014-04-01

    The production of gasses and, more particularly, to systems and methods for the production of syngas and fuel gasses including the production of hydrogen are set forth. In one embodiment system and method includes a reactor having a molten pool of a material comprising sodium carbonate. A supply of conditioned water is in communication with the reactor. A supply of carbon containing material is also in communication with the reactor. In one particular embodiment, the carbon containing material may include vacuum residuum (VR). The water and VR may be kept at desired temperatures and pressures compatible with the process that is to take place in the reactor. When introduced into the reactor, the water, the VR and the molten pool may be homogenously mixed in an environment in which chemical reactions take place including the production of hydrogen and other gasses.

  6. System and process for the production of syngas and fuel gasses

    DOEpatents

    Bingham, Dennis N; Klingler, Kerry M; Turner, Terry D; Wilding, Bruce M; Benefiel, Bradley C

    2015-04-21

    The production of gasses and, more particularly, to systems and methods for the production of syngas and fuel gasses including the production of hydrogen are set forth. In one embodiment system and method includes a reactor having a molten pool of a material comprising sodium carbonate. A supply of conditioned water is in communication with the reactor. A supply of carbon containing material is also in communication with the reactor. In one particular embodiment, the carbon containing material may include vacuum residuum (VR). The water and VR may be kept at desired temperatures and pressures compatible with the process that is to take place in the reactor. When introduced into the reactor, the water, the VR and the molten pool may be homogenously mixed in an environment in which chemical reactions take place including the production of hydrogen and other gasses.

  7. The effects of Creatine Long-Term Supplementation on Muscle Morphology and Swimming Performance in Rats

    PubMed Central

    Yildiz, Ahmet; Ozdemir, Ercan; Gulturk, Sefa; Erdal, Sena

    2009-01-01

    Creatine (Cr) has been shown to increase the total muscle mass. The purpose of this study was to investigate the effect of Cr supplementation on muscle morphology and swimming performance, using an animal model. Each rat was subjected to exercise 15-minute period daily for the 12 weeks. The rats were randomly divided into four groups: no Cr supplementation (CON), no Cr supplementation and incomplete food intake (lacking lysine and methionine in diet for rats) (INCO), Cr supplementation 1 g·kg-1·day-1 (CREAT-I) and Cr supplementation 2 g·kg-1·day-1 (CREAT-II). Three months later, all groups adult rats exercised in swimming pool chambers. Swimming time was recorded as minute for each rat. Following swimming performance period, the animals were killed by cervical dislocation and the gastrocnemius and diaphragm muscles were dissected. Serial slices of 5-7 μm were allocated paraffin wax and histochemical staining procedure of cross-sections was carried out with heamatoxylin-eosin technics. All groups gained body weight at the end of 12 weeks but there was no statistical difference among them. Swimming time values were statistical difference between CREAT-II and CON group as well as between CREAT-I and CON group (p < 0.05). In the INCO group was determined increased connective tissue cell of the muscle sample. In contrast, in the CREAT-I and CREAT-II group, the basic histological changes were large-scale muscle fibers and hypertrophic muscle cells. These results suggest that long-term creatine supplementation increased the number of muscle fibers and enhanced endurance swimming performance in rats. Key points There is no study about the effects of creatine long-term supplementation on muscle morphology and swimming performance in rats. Long-term creatine supplementation increase muscle hypertrophy (but not body weight) and enhance endurance swimming performance in rats. The quantitative analysis indicated that the number of muscle fibers per defined area increased in creatine supplementation groups. PMID:24149591

  8. SPERT Destructive Test - I on Aluminum, Highly Enriched Plate Type Core

    ScienceCinema

    None

    2018-01-16

    SPERT - Special Power Excursion Reactor Tests Destructive Test number 1 On Aluminum, Highly Enriched Plate Type Core. A test studying the behavior of the reactor under destructive conditions on a light water moderated pool-type reactor with a plate-type core.

  9. Waterborne parasites: a current status from the Philippines.

    PubMed

    Onichandran, Subashini; Kumar, Thulasi; Salibay, Cristina C; Dungca, Julieta Z; Tabo, Hazel Al; Tabo, Norbel; Tan, Tian-Chye; Lim, Yvonne Al; Sawangjaroen, Nongyao; Phiriyasamith, Sucheep; Andiappan, Hemah; Ithoi, Init; Lau, Yee-Ling; Nissapatorn, Veeranoot

    2014-05-28

    Despite the amount of awareness created, waterborne disease still poses threat, especially in developing countries. Due to the scarcity of reported data on waterborne parasites, the consumption of unsafe water prolongs. Thus, the occurrences of waterborne parasites from various samples were investigated from one of the Southeast Asian country, the Philippines. A total of thirty three samples, each consisting of twelve liters, were collected and processed to obtain the sediment. Ten liters of sample each was processed to detect Cryptosporidium spp. and Giardia spp. using an immunomagnetic separation method prior to enumeration via fluorescence microscope. Meanwhile, the remaining two liters were cultured to detect Acanthamoeba and Naegleria through microscopy examination and polymerase chain reaction (PCR) analysis. Twelve samples (36.4%) from river (5), swimming pool (1), pond (3), rain tank (1), and natural lake (2) were positive for Cryptosporidium spp., 17 (45.5%) samples from river (9), pond (2), swimming pool (1), rain tank (1), and natural lake (4) were positive for Giardia spp. while, 13 (33.3%) samples from river (3), swimming pool (2), pond (2), dispenser (1), well (1), tap (2) and natural lake (2) were positive for Acanthamoeba spp. and 5 (18.2%) samples from river (1), natural lake (1), tap (1), dispenser (1) and mineral (1) were Naegleria spp. positive. Physical parameters such as temperature, conductivity, total dissolved solid (TDS), salinity, dissolved oxygen (DO), pH, and turbidity and chemical parameters such as ammonia, chlorine, fluoride, nitrate and nitrite were also measured. The highest chemical contamination was observed at pond 2. A good correlation was observed between Giardia and nitrite (r = 0.736, p < 0.01) and Giardia and nitrate (r = 0.502, p < 0.01). This study was aimed to create greater awareness of parasitic contamination in the water environment in the Philippines and also to act as a platform of the current scenario for policymakers as water pollution is a key health issue in this region.

  10. Waterborne parasites: a current status from the Philippines

    PubMed Central

    2014-01-01

    Background Despite the amount of awareness created, waterborne disease still poses threat, especially in developing countries. Due to the scarcity of reported data on waterborne parasites, the consumption of unsafe water prolongs. Thus, the occurrences of waterborne parasites from various samples were investigated from one of the Southeast Asian country, the Philippines. Methods A total of thirty three samples, each consisting of twelve liters, were collected and processed to obtain the sediment. Ten liters of sample each was processed to detect Cryptosporidium spp. and Giardia spp. using an immunomagnetic separation method prior to enumeration via fluorescence microscope. Meanwhile, the remaining two liters were cultured to detect Acanthamoeba and Naegleria through microscopy examination and polymerase chain reaction (PCR) analysis. Results Twelve samples (36.4%) from river (5), swimming pool (1), pond (3), rain tank (1), and natural lake (2) were positive for Cryptosporidium spp., 17 (45.5%) samples from river (9), pond (2), swimming pool (1), rain tank (1), and natural lake (4) were positive for Giardia spp. while, 13 (33.3%) samples from river (3), swimming pool (2), pond (2), dispenser (1), well (1), tap (2) and natural lake (2) were positive for Acanthamoeba spp. and 5 (18.2%) samples from river (1), natural lake (1), tap (1), dispenser (1) and mineral (1) were Naegleria spp. positive. Physical parameters such as temperature, conductivity, total dissolved solid (TDS), salinity, dissolved oxygen (DO), pH, and turbidity and chemical parameters such as ammonia, chlorine, fluoride, nitrate and nitrite were also measured. The highest chemical contamination was observed at pond 2. A good correlation was observed between Giardia and nitrite (r = 0.736, p < 0.01) and Giardia and nitrate (r = 0.502, p < 0.01). Conclusion This study was aimed to create greater awareness of parasitic contamination in the water environment in the Philippines and also to act as a platform of the current scenario for policymakers as water pollution is a key health issue in this region. PMID:24885105

  11. Dismantling the nuclear research reactor Thetis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Michiels, P.

    The research reactor Thetis, in service since 1967 and stopped in 2003, is part of the laboratories of the institution of nuclear science of the University of Ghent. The reactor, of the pool-type, was used as a neutron-source for the production of radio-isotopes and for activation analyses. The reactor is situated in a water pool with inner diameter of 3 m. and a depth of 7.5 m. The reactor core is situated 5.3 m under water level. Besides the reactor, the pool contains pneumatic loops, handling tools, graphite blocks for neutron moderation and other experimental equipment. The building houses storagemore » rooms for fissile material and sources, a pneumatic circuit for transportation of samples, primary and secondary cooling circuits, water cleaning resin circuits, a ventilation system and other necessary devices. Because of the experimental character of the reactor, laboratories with glove boxes and other tools were needed and are included in the dismantling program. The building is in 3 levels with a crawl-space. The ground-floor contains the ventilation installation, the purification circuits with tanks, cooling circuits and pneumatic transport system. On the first floor, around the reactor hall, the control-room, visiting area, end-station for pneumatic transport, waste-storage room, fuel storage room and the labs are located. The second floor contains a few laboratories and end stations of the two high speed transfer tubes. The lowest level of the pool is situated under ground level. The reactor has been operated at a power of 150 kW and had a max operating power of 250 kW. Belgoprocess has been selected to decommission the reactor, the labs, storage halls and associated circuits to free release the building for conventional reuse and for the removal of all its internals as legal defined. Besides the dose-rate risk and contamination risk, there is also an asbestos risk of contamination. During construction of the installation, asbestos-containing materials were used, which must be removed in controlled conditions. The ventilation system is considered free from nuclear contamination but it contains asbestos. This paper covers the organization of the dismantling work, the technical execution aspect and conclusions already known (dismantling is ongoing as this is written). (authors)« less

  12. Analysis on the Role of RSG-GAS Pool Cooling System during Partial Loss of Heat Sink Accident

    NASA Astrophysics Data System (ADS)

    Susyadi; Endiah, P. H.; Sukmanto, D.; Andi, S. E.; Syaiful, B.; Hendro, T.; Geni, R. S.

    2018-02-01

    RSG-GAS is a 30 MW reactor that is mostly used for radioisotope production and experimental activities. Recently, it is regularly operated at half of its capacity for efficiency reason. During an accident, especially loss of heat sink, the role of its pool cooling system is very important to dump decay heat. An analysis using single failure approach and partial modeling of RELAP5 performed by S. Dibyo, 2010 shows that there is no significant increase in the coolant temperature if this system is properly functioned. However lessons learned from the Fukushima accident revealed that an accident can happen due to multiple failures. Considering ageing of the reactor, in this research the role of pool cooling system is to be investigated for a partial loss of heat sink accident which is at the same time the protection system fails to scram the reactor when being operated at 15 MW. The purpose is to clarify the transient characteristics and the final state of the coolant temperature. The method used is by simulating the system in RELAP5 code. Calculation results shows the pool cooling systems reduce coolant temperature for about 1 K as compared without activating them. The result alsoreveals that when the reactor is being operated at half of its rated power, it is still in safe condition for a partial loss of heat sink accident without scram.

  13. Warm-up and performance in competitive swimming.

    PubMed

    Neiva, Henrique P; Marques, Mário C; Barbosa, Tiago M; Izquierdo, Mikel; Marinho, Daniel A

    2014-03-01

    Warm-up before physical activity is commonly accepted to be fundamental, and any priming practices are usually thought to optimize performance. However, specifically in swimming, studies on the effects of warm-up are scarce, which may be due to the swimming pool environment, which has a high temperature and humidity, and to the complexity of warm-up procedures. The purpose of this study is to review and summarize the different studies on how warming up affects swimming performance, and to develop recommendations for improving the efficiency of warm-up before competition. Most of the main proposed effects of warm-up, such as elevated core and muscular temperatures, increased blood flow and oxygen delivery to muscle cells and higher efficiency of muscle contractions, support the hypothesis that warm-up enhances performance. However, while many researchers have reported improvements in performance after warm-up, others have found no benefits to warm-up. This lack of consensus emphasizes the need to evaluate the real effects of warm-up and optimize its design. Little is known about the effectiveness of warm-up in competitive swimming, and the variety of warm-up methods and swimming events studied makes it difficult to compare the published conclusions about the role of warm-up in swimming. Recent findings have shown that warm-up has a positive effect on the swimmer's performance, especially for distances greater than 200 m. We recommend that swimmers warm-up for a relatively moderate distance (between 1,000 and 1,500 m) with a proper intensity (a brief approach to race pace velocity) and recovery time sufficient to prevent the early onset of fatigue and to allow the restoration of energy reserves (8-20 min).

  14. Effects of 4 weeks of creatine supplementation in junior swimmers on freestyle sprint and swim bench performance.

    PubMed

    Dawson, Brian; Vladich, Todd; Blanksby, Brian A

    2002-11-01

    To determine whether 4 weeks of oral creatine (Cr) supplementation could enhance single freestyle sprint and swim bench performance in experienced competitive junior swimmers, 10 young men and 10 young women (x age = 16.4 +/- 1.8 years) participated in a 27-day supplementation period and pre- and posttesting sessions. In session 1 (presupplementation testing), subjects swam one 50-m freestyle and then (after approximately 5 minutes of active recovery) one 100-m freestyle at maximum speed. Blood lactate was measured before and 1 minute after each swim trial. Forty-eight hours later, height, mass, and the sum of 6 skinfolds were recorded, and a Biokinetic Swim Bench total work output test (2 x 30-second trials, with a 10-minute passive recovery in between) was undertaken. After the pretests were completed, participants were divided into 2 groups (n = 10, Cr; and n = 10, placebo) by means of matched pairs on the basis of gender and 50-m swim times. A Cr loading phase of 20 g x d(-1) for 5 days was then instituted, followed by a maintenance phase of 5 g x d(-1) for 22 days. Postsupplementation testing replicated the presupplementation tests. Four weeks of Cr supplementation did not influence single sprint performance in the pool or body mass and composition. However, 30-second swim bench total work scores for trial 1 and trial 2 increased after Cr (p < 0.05) but not placebo ingestion. Postexercise blood lactate values were not different after supplementation for the 50- and 100-m sprint trials either within or between groups. It was concluded that 4 weeks of Cr supplementation did not significantly improve single sprint performance in competitive junior swimmers, but it did enhance swim bench test performance.

  15. The Effects of Leg Kick on Swimming Speed and Arm-Stroke Efficiency in the Front Crawl.

    PubMed

    Silveira, Ricardo Peterson; de Souza Castro, Flávio Antônio; Figueiredo, Pedro; Vilas-Boas, João Paulo; Zamparo, Paola

    2017-07-01

    To analyze the effects of swimming pace on the relative contribution of leg kick to swimming speed and to compare arm-stroke efficiency (ηF) assessed when swimming with the arms only (SAO) and while swimming front crawl (FCS) using individual and fixed adjustments to arm-stroke and leg-kick contribution to forward speed. Twenty-nine master swimmers (21 men, 8 women) performed SAO and FCS at 6 self-selected speeds from very slow to maximal. The average swimming speed (v), stroke frequency (SF), and stroke length (SL) were assessed in the central 10 m of the swimming pool. Then, a 2nd-order polynomial regression was used to obtain values of v at paired SF. The percentage difference in v between FCS and SAO, for each paired SF, was used to calculate the relative contributions of the arm stroke (AC) and leg kick (LC) to FCS. Then ηF was calculated using the indirect "paddle-wheel" approach in 3 different ways: using general, individual, and no adjustments to AC. The LC increased with SF (and speed) from -1% ± 4% to 11% ± 1% (P < .05). At the lower FCS speeds, ηF calculated using general adjustments was lower than ηF calculated using individual adjustments (P < .05), but differences disappear at the fastest speeds. Finally, ηF calculated using individual adjustments to LC in the FCS condition did not differ with ηF assessed in the SAO condition at all the investigated speeds. The relative contributions of the arm stroke and leg kick should be individually estimated to reduce errors when calculating arm-stroke efficiency at different speeds and in different swimmers.

  16. BWR zero pressure containment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dillmann, C.W.; Townsend, H.E.; Nesbitt, L.B.

    1992-02-25

    This patent describes the operation of a nuclear reactor system, the system including a containment defining a drywall space wherein a nuclear reactor is disposed, there being a suppression pool in the containment with the suppression pool having a wetwell space above a level of the pool to which an non-condensable gases entering the suppression pool can vent. It comprises: continuously exhausting the wetwell space to remove gas mixture therefrom while admitting inflow of air from an atmospheric source thereof to the wetwell during normal operation by blocking off the inflow during a loss-of-coolant-accident whenever a pressure in the wetwellmore » space is above a predetermined value, and subjecting the gas subsequent to its removal from the wetwell to a treatment operation to separate any particulate material entrained therein from the gas mixture.« less

  17. Measurement of hydrodynamic force generation by swimming dolphins using bubble DPIV.

    PubMed

    Fish, Frank E; Legac, Paul; Williams, Terrie M; Wei, Timothy

    2014-01-15

    Attempts to measure the propulsive forces produced by swimming dolphins have been limited. Previous uses of computational hydrodynamic models and gliding experiments have provided estimates of thrust production by dolphins, but these were indirect tests that relied on various assumptions. The thrust produced by two actively swimming bottlenose dolphins (Tursiops truncatus) was directly measured using digital particle image velocimetry (DPIV). For dolphins swimming in a large outdoor pool, the DPIV method used illuminated microbubbles that were generated in a narrow sheet from a finely porous hose and a compressed air source. The movement of the bubbles was tracked with a high-speed video camera. Dolphins swam at speeds of 0.7 to 3.4 m s(-1) within the bubble sheet oriented along the midsagittal plane of the animal. The wake of the dolphin was visualized as the microbubbles were displaced because of the action of the propulsive flukes and jet flow. The oscillations of the dolphin flukes were shown to generate strong vortices in the wake. Thrust production was measured from the vortex strength through the Kutta-Joukowski theorem of aerodynamics. The dolphins generated up to 700 N during small amplitude swimming and up to 1468 N during large amplitude starts. The results of this study demonstrated that bubble DPIV can be used effectively to measure the thrust produced by large-bodied dolphins.

  18. Close the Achievement Gap with Summer Learning

    ERIC Educational Resources Information Center

    Huggins, Gary

    2012-01-01

    Summer vacation from school can bring afternoons at the swimming pool, family vacations, and maybe a spirit-filled summer camp that ignites a passion for art or rock climbing. But for many children, summer also means setbacks in learning that take a tremendous toll on teaching and student performance over time. PTA leaders can make a vital…

  19. From Swimming Pool to Collaborative Learning Studio: Pedagogy, Space, and Technology in a Large Active Learning Classroom

    ERIC Educational Resources Information Center

    Lee, Dabae; Morrone, Anastasia S.; Siering, Greg

    2018-01-01

    To promote student learning and bolster student success, higher education institutions are increasingly creating large active learning classrooms to replace traditional lecture halls. Although there have been many efforts to examine the effects of those classrooms on learning outcomes, there is paucity of research that can inform the design and…

  20. Lawriter - OAC

    Science.gov Websites

    authorized by section 3709.05 of the Revised Code. (C) "Circulation system" means an arrangement of transferred and does not mean the person who formerly operated or maintained the public swimming pool. (J ://catalog.asme.org/. ASME documents are also generally available at the state library of Ohio. (c) American national

  1. An Ocean of Possibilities

    ERIC Educational Resources Information Center

    Williams, Doug

    2010-01-01

    For more than one hundred years teachers have paddled beside the great ocean of mathematical adventure. Between them they have taught millions of young people. A few have dived in and kept swimming, some have lingered on the shore playing in pools, but most have dipped their toes in and run like heck in the other direction never to return. There…

  2. Military Librarians Workshop (19th). Intellectual Updating: Changes in the State of the Art of Librarianship, 30 September - 2 October 1975

    DTIC Science & Technology

    1975-01-01

    Force instructor pilots two swimming pools, basketball will administer the 18 hours of this courts, squash and handball courts, program. Additional...Group Annex Fort Lee, VA 23801 Naval Weapons Station. Seal Beach Corona, CA 91720 ELDEEN J. GREENLAND Library Technician MARGARET L. GALLAGHER USA

  3. ADJUSTABLE OUTPUT RATE CHEMICAL FEEDING EQUIPMENT FOR SWIMMING POOLS. NATIONAL SANITATION FOUNDATION STANDARD NUMBER 19.

    ERIC Educational Resources Information Center

    National Sanitation Foundation, Ann Arbor, MI.

    THE SCOPE OF THIS STANDARD COVERS ADJUSTABLE OUTPUT RATE CHEMICAL FEEDERS, WHETHER USED FOR SOLUTIONS, SLURRIES OR SOLIDS. IT ALSO INCLUDES AUXILIARY EQUIPMENT SUCH AS PUMPS, STRAINERS, TUBING CONNECTIONS, TANKS, INJECTION FITTINGS AND OTHER REQUIRED COMPONENTS. THE FEEDERS DESCRIBED ARE INTENDED TO BE DESIGNED AND USED SPECIFICALLY FOR CHEMICAL…

  4. Depletion Of The Protective Aluminum Hydroxide Coating In TiO2-Based Sunscreens By Swimming Pool Water Ingredients

    EPA Science Inventory

    In sunscreen lotion (SSL) formulations, titanium dioxide (nTiO2) nanoparticles are coated with an Al(OH)3 layer to shield against the harmful effects of hydroxyl radicals (•OH), superoxide anion radicals (O2-•), and other reactive oxyge...

  5. Solar-heated swimming school--Wilmington, Delaware

    NASA Technical Reports Server (NTRS)

    1981-01-01

    Report describes operation, installation, and performance of solar-energy system which provides alternative to natural gas pool heating. System is comprised of 2,500 square feet of liquid flat-plate collectors connected to 3,600 galloon; gallongalloon storage tank, with microcomputer-based controls. Extension of building incorporates vertical-wall, passive collection system which provides quarter of heated fresh air for office.

  6. Hector Garcia Middle School: A School's Design Aspires to Live Up to Its Name

    ERIC Educational Resources Information Center

    Brown, Peter

    2007-01-01

    Brown discusses the history of Hector Garcia, a Mexican immigrant who, as U.S. Army captain, worked diligently to assist minority servicemen in navigating the Veterans Administration, and found the GI Forum. Dr. Garcia's activism, through the Forum, was instrumental in desegregating hospitals, swimming pools, schools and cemeteries. Brown's case…

  7. Sink or Swim in the Labor Pool: Determinants and Consequences of Teenage Employment

    ERIC Educational Resources Information Center

    Voloshin, Irina

    2012-01-01

    A majority of all high school students engage in the labor force by the time they complete their senior year. Few studies have investigated the long-term educational trajectories of student workers after high school graduation. Even fewer research studies have concerned themselves with ascriptive stratification patterns of the teenage labor…

  8. LPT. Shield test facility test building interior (TAN646). Camera facing ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    LPT. Shield test facility test building interior (TAN-646). Camera facing south. Distant pool contained EBOR reactor; near pool was intended for fuel rod storage. Other post-1970 activity equipment remains in pool. INEEL negative no. HD-40-9-4 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID

  9. Water inventory management in condenser pool of boiling water reactor

    DOEpatents

    Gluntz, Douglas M.

    1996-01-01

    An improved system for managing the water inventory in the condenser pool of a boiling water reactor has means for raising the level of the upper surface of the condenser pool water without adding water to the isolation pool. A tank filled with water is installed in a chamber of the condenser pool. The water-filled tank contains one or more holes or openings at its lowermost periphery and is connected via piping and a passive-type valve (e.g., squib valve) to a high-pressure gas-charged pneumatic tank of appropriate volume. The valve is normally closed, but can be opened at an appropriate time following a loss-of-coolant accident. When the valve opens, high-pressure gas inside the pneumatic tank is released to flow passively through the piping to pressurize the interior of the water-filled tank. In so doing, the initial water contents of the tank are expelled through the openings, causing the water level in the condenser pool to rise. This increases the volume of water available to be boiled off by heat conducted from the passive containment cooling heat exchangers. 4 figs.

  10. Water inventory management in condenser pool of boiling water reactor

    DOEpatents

    Gluntz, D.M.

    1996-03-12

    An improved system for managing the water inventory in the condenser pool of a boiling water reactor has means for raising the level of the upper surface of the condenser pool water without adding water to the isolation pool. A tank filled with water is installed in a chamber of the condenser pool. The water-filled tank contains one or more holes or openings at its lowermost periphery and is connected via piping and a passive-type valve (e.g., squib valve) to a high-pressure gas-charged pneumatic tank of appropriate volume. The valve is normally closed, but can be opened at an appropriate time following a loss-of-coolant accident. When the valve opens, high-pressure gas inside the pneumatic tank is released to flow passively through the piping to pressurize the interior of the water-filled tank. In so doing, the initial water contents of the tank are expelled through the openings, causing the water level in the condenser pool to rise. This increases the volume of water available to be boiled off by heat conducted from the passive containment cooling heat exchangers. 4 figs.

  11. Trench fast reactor design using the microcomputer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rohach, A.F.; Sankoorikal, J.T.; Schmidt, R.R.

    1987-01-01

    This project is a study of alternative liquid-metal-cooled fast power reactor system concepts. Specifically, an unconventional primary system is being conceptually designed and evaluated. The project design is based primarily on microcomputer analysis through the use of computational modules. The reactor system concept is a long, narrow pool with a long, narrow reactor called a trench-type pool reactor in it. The reactor consists of five core-blanket modules in a line. Specific power is to be modest, permitting long fuel residence time. Two fuel cycles are currently being considered. The reactor design philosophy is that of the inherently safe concept. Thismore » requires transient analysis dependent on reactivity coefficients: prompt fuel, including Doppler and expansion, fuel expansion, sodium temperature and void, and core expansion. Conceptual reactor design is done on a microcomputer. A part of the trench reactor project is to develop a microcomputer-based system that can be used by the user for scoping studies and design. Current development includes the neutronics and fuel management aspects of the design. Thermal-hydraulic analysis and economics are currently being incorporated into the microcomputer system. The system is menu-driven including preparation of program input data and of output data for displays in graphics form.« less

  12. An Assessment of Fission Product Scrubbing in Sodium Pools Following a Core Damage Event in a Sodium Cooled Fast Reactor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bucknor, M.; Farmer, M.; Grabaskas, D.

    The U.S. Nuclear Regulatory Commission has stated that mechanistic source term (MST) calculations are expected to be required as part of the advanced reactor licensing process. A recent study by Argonne National Laboratory has concluded that fission product scrubbing in sodium pools is an important aspect of an MST calculation for a sodium-cooled fast reactor (SFR). To model the phenomena associated with sodium pool scrubbing, a computational tool, developed as part of the Integral Fast Reactor (IFR) program, was utilized in an MST trial calculation. This tool was developed by applying classical theories of aerosol scrubbing to the decontamination ofmore » gases produced as a result of postulated fuel pin failures during an SFR accident scenario. The model currently considers aerosol capture by Brownian diffusion, inertial deposition, and gravitational sedimentation. The effects of sodium vapour condensation on aerosol scrubbing are also treated. This paper provides details of the individual scrubbing mechanisms utilized in the IFR code as well as results from a trial mechanistic source term assessment led by Argonne National Laboratory in 2016.« less

  13. Mechanical power, thrust power and propelling efficiency: relationships with elite sprint swimming performance.

    PubMed

    Gatta, Giorgio; Cortesi, Matteo; Swaine, Ian; Zamparo, Paola

    2018-03-01

    The purpose of this study was to explore the relationships between mechanical power, thrust power, propelling efficiency and sprint performance in elite swimmers. Mechanical power was measured in 12 elite sprint male swimmers: (1) in the laboratory, by using a whole-body swimming ergometer (W' TOT ) and (2) in the pool, by measuring full tethered swimming force (F T ) and maximal swimming velocity (V max ): W' T  = F T  · V max . Propelling efficiency (η P ) was estimated based on the "paddle wheel model" at V max . V max was 2.17 ± 0.06 m · s -1 , η P was 0.39 ± 0.02, W' T was 374 ± 62 W and W' TOT was 941 ± 92 W. V max was better related to W' T (useful power output: R = 0.943, P < 0.001) than to W' TOT (total power output: R = 0.744, P < 0.01) and this confirms the use of the full tethered test as a valid test to assess power propulsion in sprinters and to estimate swimming performance. The ratio W' T /W' TOT (0.40 ± 0.04) represents the fraction of total mechanical power that can be utilised in water (e.g., η P ) and was indeed the same as that estimated based on the "paddle wheel model"; this supports the use of this model to estimate η P in swimming.

  14. Nosocomial outbreak of Pseudomonas aeruginosa folliculitis associated with a physiotherapy pool.

    PubMed Central

    Schlech, W F; Simonsen, N; Sumarah, R; Martin, R S

    1986-01-01

    Outbreaks of community-acquired Pseudomonas aeruginosa folliculitis have recently been described in association with health spa whirlpools. In February 1984 we detected an outbreak of Pseudomonas folliculitis among hospital staff and patients using a swimming pool in a newly constructed physiotherapy unit. A rash developed in 5 (45%) of the 11 physiotherapists who had used the pool, as compared with 0 of the 17 who had not (p less than 0 005). Pseudomonas folliculitis also developed in 6 (21%) of 29 outpatients and 4 (33%) of 12 inpatients who had used the facility; Pseudomonas infection of a surgical wound also developed in 1 of the 4 inpatients. The epidemic curve was consistent with a continuing common-source outbreak. P. aeruginosa, serotype O:10, was isolated from three physiotherapists, the patient with an infected surgical wound and the pool. A case-control study of pool users did not identify risk factors for infection, although the physiotherapists had spent longer in the pool than had the patients. After hyperchlorination and structural repairs to the pool, no further cases were identified among pool users. This outbreak is the first reported nosocomial outbreak of Pseudomonas folliculitis. Further investigation is needed to determine the risk of serious Pseudomonas infections in hospitalized patients using physiotherapy pools. Images Fig. 1 PMID:3955486

  15. Differences in the energy cost between children and adults during front crawl swimming.

    PubMed

    Kjendlie, Per-Ludvik; Ingjer, Frank; Madsen, Ørjan; Stallman, Robert Keig; Stray-Gundersen, James

    2004-04-01

    There is little information available about the swimming economy of children. The aim of this study was to examine any possible differences in swimming economy in children and adults, swimming front crawl submaximally. Swimming economy was compared in adults [ n=13, aged 21.4 (3.7) years] and children [n=10, aged 11.8 (0.8) years] tested at four submaximal 6-min workloads. Oxygen consumption (VO2) was measured with Douglas bags in a 25-m pool and pacer lights were used to control the velocities. Swimming economy was scaled to body size using mass (BM), body surface area (BSA) and body length (BL). Children had lower VO2 (litres per minute) at a given velocity than the adults, with 1.86 (0.28) and 2.39 (0.20) l min(-1) respectively (at 1.00 m s(-1)). When scaling for size, children had higher VO2 measured in litres per square metre per minute and millilitres per kilogram per minute (divided by BSA and BM) than adults. The VO2 divided by BL was found not to differ between the two groups. The O2 cost of swimming 1 m at a velocity of 1.00 m s(-1) was lower in the children [31.0 (4.6) ml m(-1)] than in the adults [39.9 (3.3) ml m(-1) P<0.01], probably due to a lower total drag in the children. The results also showed that for children a relationship between swimming velocity cubed and VO2 exists as shown earlier for adults. It is concluded that, when scaling for BSA and BM, children are less economical than adults, when scaling for BL, children are equally economical, and when considering energy cost per metre and absolute VO2, children are more economical than the adults.

  16. Chlorinated pool attendance, airway epithelium defects and the risks of allergic diseases in adolescents: Interrelationships revealed by circulating biomarkers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bernard, Alfred, E-mail: Alfred.bernard@uclouvain.be; Nickmilder, Marc; Dumont, Xavier

    It has been suggested that allergic diseases might be epithelial disorders driven by various environmental stressors but the epidemiological evidence supporting this concept is limited. In a cross-sectional study of 835 school adolescents (365 boys; mean age, 15.5 yr), we measured the serum concentrations of Club cell protein (CC16), surfactant-associated protein D (SP-D) and of total and aeroallergen-specific IgE. We used the serum CC16/SP-D concentration ratio as an index integrating changes in the permeability (SP-D) and secretory function (CC16) of the airway epithelium. In both sexes, early swimming in chlorinated pools emerged as the most consistent and strongest predictor ofmore » low CC16 and CC16/SP-D ratio in serum. Among girls, a low CC16/SP-D ratio was associated with increased odds (lowest vs. highest tertile) for pet sensitization (OR 2.97, 95% CI 1.19–8.22) and for hay fever in subjects sensitized to pollen (OR 4.12, 95% CI 1.28–14.4). Among boys, a low CC16/SP-D ratio was associated with increased odds for house-dust mite (HDM) sensitization (OR 2.01, 95% CI 1.11–3.73), for allergic rhinitis in subjects sensitized to HDM (OR 3.52, 95% CI 1.22–11.1) and for asthma in subjects sensitized to any aeroallergen (OR 3.38, 95% CI 1.17–11.0), HDM (OR 5.20, 95% CI 1.40–24.2) or pollen (OR 5.82, 95% CI 1.51–27.4). Odds for allergic sensitization or rhinitis also increased with increasing SP-D or decreasing CC16 in serum. Our findings support the hypothesis linking the development of allergic diseases to epithelial barrier defects due to host factors or environmental stressors such as early swimming in chlorinated pools. - Highlights: • We conducted a cross-sectional study of 835 school adolescents. • The airway epithelium integrity was evaluated by measuring serum pneumoproteins. • The risk of allergic diseases was associated with a defective airway epithelium. • Childhood swimming in chlorinated pools can cause persistent epithelial alterations.« less

  17. Interfacial heat transfer in multiphase molten pools with gas injection

    NASA Astrophysics Data System (ADS)

    Bilbao Y Leon, Rosa Marina

    1998-12-01

    In the very unlikely event of a severe reactor accident involving core meltdown and pressure vessel failure, it is vital to identify the circumstances that would allow the molten core material to cool down and resolidify, bringing core debris to a safe and stable state. In this type of accident, the molten material which escapes from the reactor pressure vessel will accumulate as a molten pool in the reactor cavity below. To achieve coolability of the corium in this configuration it has been proposed to flood the cavity with water from above forming a layered structure where upward heat loss from the molten pool to the water will cause the core material to quench and solidify. The effectiveness of this procedure depends largely on the rate of upward heat loss as well as on the formation and stability of an upper crust. In this situation the molten pool becomes a three phase mixture: the solid and liquid slurry formed by the molten pool cooled to a temperature below the temperature of liquidus, agitated by the gases formed in the concrete ablation process. The present work quantifies the partition of the heat losses upward and downward considering the influence of the solid fraction in the pool and the viscosity effects, and the rate of heat loss through a solid layer. To complete this task a intermediate scale experimental test section has been designed and built at the University of Wisconsin - Madison, in which simulant materials are used to model the process of heat and mass transfer which involves the molten pool, the solid layer atop and the coolant layer above. The design includes volumetric heating, gas injection from the bottom and solids within the pool. New experimental results showing the heat transfer behavior for pools with different viscosities and various solid fractions are presented. The current results indicate a power split which favors heat transfer upward to the coolant simulant above by a 2:1 or 3:1 ratio. In addition, the power split is unaffected by the viscosity of the pool, the solid fractions in the pool and the superficial velocity.

  18. Randomized Trial of Two Dissemination Strategies for a Skin Cancer Prevention Program in Aquatic Settings

    PubMed Central

    Escoffery, Cam; Elliott, Tom; Nehl, Eric J.

    2015-01-01

    Objectives. We compared 2 strategies for disseminating an evidence-based skin cancer prevention program. Methods. We evaluated the effects of 2 strategies (basic vs enhanced) for dissemination of the Pool Cool skin cancer prevention program in outdoor swimming pools on (1) program implementation, maintenance, and sustainability and (2) improvements in organizational and environmental supports for sun protection. The trial used a cluster-randomized design with pools as the unit of intervention and outcome. The enhanced group received extra incentives, reinforcement, feedback, and skill-building guidance. Surveys were collected in successive years (2003–2006) from managers of 435 pools in 33 metropolitan areas across the United States participating in the Pool Cool Diffusion Trial. Results. Both treatment groups improved their implementation of the program, but pools in the enhanced condition had significantly greater overall maintenance of the program over 3 summers of participation. Furthermore, pools in the enhanced condition established and maintained significantly greater sun-safety policies and supportive environments over time. Conclusions. This study found that more intensive, theory-driven dissemination strategies can significantly enhance program implementation and maintenance of health-promoting environmental and policy changes. Future research is warranted through longitudinal follow-up to examine sustainability. PMID:25521872

  19. The detector system of the Daya Bay reactor neutrino experiment

    DOE PAGES

    An, F. P.

    2015-12-15

    The Daya Bay experiment was the first to report simultaneous measurements of reactor antineutrinos at multiple baselines leading to the discovery of ν¯e oscillations over km-baselines. Subsequent data has provided the world's most precise measurement of sin 22θ 13 and the effective mass splitting Δm 2 ee. The experiment is located in Daya Bay, China where the cluster of six nuclear reactors is among the world's most prolific sources of electron antineutrinos. Multiple antineutrino detectors are deployed in three underground water pools at different distances from the reactor cores to search for deviations in the antineutrino rate and energy spectrummore » due to neutrino mixing. Instrumented with photomultiplier tubes, the water pools serve as shielding against natural radioactivity from the surrounding rock and provide efficient muon tagging. Arrays of resistive plate chambers over the top of each pool provide additional muon detection. The antineutrino detectors were specifically designed for measurements of the antineutrino flux with minimal systematic uncertainty. Relative detector efficiencies between the near and far detectors are known to better than 0.2%. With the unblinding of the final two detectors’ baselines and target masses, a complete description and comparison of the eight antineutrino detectors can now be presented. This study describes the Daya Bay detector systems, consisting of eight antineutrino detectors in three instrumented water pools in three underground halls, and their operation through the first year of eight detector data-taking.« less

  20. Gas Fride Heat Pumps : The Present and Future

    NASA Astrophysics Data System (ADS)

    Kurosawa, Shigekichi; Ogura, Masao

    In japan techniques for saving energy is an important goal since energy resources such as oil and nuclear power are limited. Recently gas fired absorption heat pumps and gas engine driven heat pumps have been installed in facilifies such as hotels, swimming pools and offices.
    In this article recent techniques, applications and future aspects for gas fired heat pumps are explained.

  1. Seismic seiches

    USGS Publications Warehouse

    McGarr, Arthur; Gupta, Harsh K.

    2011-01-01

    Seismic seiche is a term first used by Kvale (1955) to discuss oscillations of lake levels in Norway and England caused by the Assam earthquake of August 15, 1950. This definition has since been generalized to apply to standing waves set up in closed, or partially closed, bodies of water including rivers, shipping channels, lakes, swimming pools and tanks due to the passage of seismic waves from an earthquake.

  2. Umweltverschmutzung. German Ecology Packet: Resource Units and Materials for German Classes at All Levels.

    ERIC Educational Resources Information Center

    Archer, Julie; And Others

    Supplementary resource materials for use in upper level secondary school German classes are presented in this text. Teachers who are seeking new content and are willing to adapt these instructional materials on ecology in Germany will find three self-contained units on: The Plight of the Polar Bear, Polluted Swimming Pools in Germany, and Dead…

  3. Final Environmental Planning Technical Report. Land Use

    DTIC Science & Technology

    1984-01-01

    COLLEGE RECREATIONAL FACILITIES Recreational Facilities Number Indoor Facilities Gym (Basketball, Volleyball) 1 Weight Room 1 Handball /Racquetball...Clubs/Gymnasiums 4 YMCA Gloria Stevens Figure Salon Nautilus Fitness Center Rocky Mountain Health Club 10 handball /racquetball courts, swimming pool, gym...Range I Roller Rink 1 Indoor Handball /Racquetball Courts 5 Indoor Softball Diamonds 3 Lighted Picnic Tables 14 Youth Baseball Diamonds 5 Tennis Courts

  4. Derivation and Validation of a Material Model for Clayey Sand for Use in Landmine Detonation Computational Analyses

    DTIC Science & Technology

    2008-01-01

    pit floor is built using a commercial swimming pool liner. Once the pit liners are in place, a series of water hoses is placed in pit bottom to...Belvoir RDEC, 1993. [9]. D. Bergeron, S. Hlady and M. P. Braid , 17th International MABS Symposium, 2002. [10]. M. Grujicic, B. Pandurangan and B

  5. Constant supervision of bathing in French public swimming pools: an unrealistic regulatory requirement?

    PubMed

    Vignac, Élie; Lebihain, Pascal; Soulé, Bastien

    2017-09-01

    In France, to prevent drowning accidents in public swimming pools (PSPs), bathing must be constantly supervised by qualified staff. However, fatal drowning regularly occurs in supervised aquatic facilities. A review of the literature shows that human supervision is a complex task. The aim of this research is to fully assess the periods during which supervision is not carried out, or carried out in an inadequate manner. The observations made in 108 French PSPs show that supervision is not carried out 18% of the time and that it is carried out inadequately 33% of the time. The medical literature shows that, in order to expect to survive without after-effects, an immersed victim requires intervention within a time limit of not more than three minutes; however, we noted, over a total observation time of 54 hours, 147 periods (29.8%) during which the supervision system was degraded for three minutes or more. This quantification research on the periods of degraded supervision is complemented by an identification of the causes leading to these degradations, from which we can draw interesting areas for improvement, particularly from an organizational point of view, in order to improve safety management in French PSPs.

  6. Immersible solar heater for fluids

    DOEpatents

    Hazen, T.C.; Fliermans, C.B.

    1994-01-01

    An immersible solar heater is described comprising a light-absorbing panel attached to a frame for absorbing heat energy from the light and transferring the absorbed heat energy directly to the fluid in which the heater is immersed. The heater can be used to heat a swimming pool, for example, and is held in position and at a preselected angle by a system of floats, weights and tethers so that the panel can operate efficiently. A skid can be used in one embodiment to prevent lateral movement of the heater along the bottom of the pool. Alternative embodiments include different arrangements of the weights, floats and tethers and methods for making the heater.

  7. Immersible solar heater for fluids

    DOEpatents

    Kronberg, James W.

    1995-01-01

    An immersible solar heater comprising a light-absorbing panel attached to a frame for absorbing heat energy from the light and transferring the absorbed heat energy directly to the fluid in which the heater is immersed. The heater can be used to heat a swimming pool, for example, and is held in position and at a preselected angle by a system of floats, weights and tethers so that the panel can operate efficiently. A skid can be used in one embodiment to prevent lateral movement of the heater along the bottom of the pool. Alternative embodiments include different arrangements of the weights, floats and tethers and methods for making the heater.

  8. The Underwater Spectrometric System Based on CZT Detector for Survey of the Bottom of MR Reactor Pool - 13461

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Potapov, Victor; Safronov, Alexey; Ivanov, Oleg

    2013-07-01

    The underwater spectrometer system for detection of irradiated nuclear fuel on the pool bottom of the reactor was elaborated. During the development process metrological studies of CdZnTe (CZT) detectors were conducted. These detectors are designed for spectrometric measurements in high radiation fields. A mathematical model based on the Monte Carlo method was created to evaluate the capability of such a system. A few experimental models were realized and the characteristics of the spectrometric system are represented. (authors)

  9. Fuel subassembly leak test chamber for a nuclear reactor

    DOEpatents

    Divona, Charles J.

    1978-04-04

    A container with a valve at one end is inserted into a nuclear reactor coolant pool. Once in the pool, the valve is opened by a mechanical linkage. An individual fuel subassembly is lifted into the container by a gripper; the valve is then closed providing an isolated chamber for the subassembly. A vacuum is drawn on the chamber to encourage gaseous fission product leakage through any defects in the cladding of the fuel rods comprising the subassembly; this leakage may be detected by instrumentation, and the need for replacement of the assembly ascertained.

  10. A Single-Unit Design Structure and Gender Differences in the Swimming World Championships

    PubMed Central

    Pushkar, Svetlana; Issurin, Vladimir B.; Verbitsky, Oleg

    2014-01-01

    Four 50 meter male/female finals - the freestyle, butterfly, breaststroke, and backstroke - swum during individual events at the Swimming World Championships (SWCs) can be defined in four clusters. The aim of the present study was to use a single-unit design structure, in which the swimmer was defined at only one scale, to evaluate gender differences in start reaction times among elite swimmers in 50 m events. The top six male and female swimmers in the finals of four swimming stroke final events in six SWCs were analyzed. An unpaired t-test was used. The p-values were evaluated using Neo-Fisherian significance assessments (Hurlbert and Lombardi, 2012). For the freestyle, gender differences in the start reaction times were positively identified for five of the six SWCs. For the backstroke, gender differences in the start reaction times could be dismissed for five of the six SWCs. For both the butterfly and breaststroke, gender differences in the start reaction times yielded inconsistent statistical differences. Pooling all swimmers together (df = 286) showed that an overall gender difference in the start reaction times could be positively identified: p = 0.00004. The contrast between the gender differences in start reaction times between the freestyle and backstroke may be associated with different types of gender adaptations to swimming performances. When the natural groupings of swimming stroke final events were ignored, sacrificial pseudoreplication occurred, which may lead to erroneous statistical differences. PMID:25414754

  11. Postnatal cocaine exposure: effects on behavior of rats in forced swim test.

    PubMed

    Magalhães, Ana; Tavares, Maria Amélia; de Sousa, Liliana

    2002-06-01

    Exposure to cocaine in early periods of postnatal life has adverse effects on behavior, namely, it induces the display of anxiety and fear-like behaviors that are associated with stress and depression. This study examined the effects of early developmental cocaine exposure in several categories of behavior observed in forced swim test. Male and female Wistar rats were given 15 mg/kg of cocaine hydrochloride/body weight/day, subcutaneously, in two daily doses, from postnatal day (PND) 1 to PND27. Controls were saline injected in the same protocol. In PND26-PND27, rats were placed in a swimming pool during 5 min in two sessions. The categories of behavior studied in this work included horizontal and vertical rotation, vibrissae clean, head clean, fast and slow swim, struggling, floating, sliding, diving, head-diving, and wagging head. Results showed differences in the frequencies of several behavioral categories that allowed the discrimination of the behaviors that may constitute "behavioral despair" indicators, as well as which behaviors are most affected by cocaine exposure. Cocaine groups were less active and more immobile than controls. These results suggest that postnatal exposure to cocaine can produce depression-like effects and affect the ability of these animals to cope with stress situations.

  12. Beta decay heat following U-235, U-238 and Pu-239 neutron fission

    NASA Astrophysics Data System (ADS)

    Li, Shengjie

    1997-09-01

    This is an experimental study of beta-particle decay heat from 235U, 239Pu and 238U aggregate fission products over delay times 0.4-40,000 seconds. The experimental results below 2s for 235U and 239Pu, and below 20s for 238U, are the first such results reported. The experiments were conducted at the UMASS Lowell 5.5-MV Van de Graaff accelerator and 1-MW swimming-pool research reactor. Thermalized neutrons from the 7Li(p,n)7Be reaction induced fission in 238U and 239Pu, and fast neutrons produced in the reactor initiated fission in 238U. A helium-jet/tape-transport system rapidly transferred fission fragments from a fission chamber to a low background counting area. Delay times after fission were selected by varying the tape speed or the position of the spray point relative to the beta spectrometer that employed a thin-scintillator-disk gating technique to separate beta-particles from accompanying gamma-rays. Beta and gamma sources were both used in energy calibration. Based on low-energy(<1 MeV) internal-conversion electron studies, a set of trial responses for the spectrometer was established and spanned electron energies 0-10 MeV. Measured beta spectra were unfolded for their energy distributions by the program FERD, and then compared to other measurements and summation calculations based on ENDF/B-VI fission-product data performed on the LANL Cray computer. Measurements of the beta activity as a function of decay time furnished a relative normalization. Results for the beta decay heat are presented and compared with other experimental data and the summation calculations.

  13. Design of conduction cooling system for a high current HTS DC reactor

    NASA Astrophysics Data System (ADS)

    Dao, Van Quan; Kim, Taekue; Le Tat, Thang; Sung, Haejin; Choi, Jongho; Kim, Kwangmin; Hwang, Chul-Sang; Park, Minwon; Yu, In-Keun

    2017-07-01

    A DC reactor using a high temperature superconducting (HTS) magnet reduces the reactor’s size, weight, flux leakage, and electrical losses. An HTS magnet needs cryogenic cooling to achieve and maintain its superconducting state. There are two methods for doing this: one is pool boiling and the other is conduction cooling. The conduction cooling method is more effective than the pool boiling method in terms of smaller size and lighter weight. This paper discusses a design of conduction cooling system for a high current, high temperature superconducting DC reactor. Dimensions of the conduction cooling system parts including HTS magnets, bobbin structures, current leads, support bars, and thermal exchangers were calculated and drawn using a 3D CAD program. A finite element method model was built for determining the optimal design parameters and analyzing the thermo-mechanical characteristics. The operating current and inductance of the reactor magnet were 1,500 A, 400 mH, respectively. The thermal load of the HTS DC reactor was analyzed for determining the cooling capacity of the cryo-cooler. The study results can be effectively utilized for the design and fabrication of a commercial HTS DC reactor.

  14. Solar thermal heating and cooling. A bibliography with abstracts

    NASA Technical Reports Server (NTRS)

    Arenson, M.

    1979-01-01

    This bibliographic series cites and abstracts the literature and technical papers on the heating and cooling of buildings with solar thermal energy. Over 650 citations are arranged in the following categories: space heating and cooling systems; space heating and cooling models; building energy conservation; architectural considerations, thermal load computations; thermal load measurements, domestic hot water, solar and atmospheric radiation, swimming pools; and economics.

  15. Landmark Learning in a Navigation Task Is Not Affected by the Female Rats' Estrus Cycle

    ERIC Educational Resources Information Center

    Rodriguez, Clara A.; Aguilar, Raul; Chamizo, V. D.

    2011-01-01

    In two experiments rats were required to escape from a circular pool by swimming to an invisible platform that was located in the same place relative to one configuration of two landmarks (X and Y). The two landmarks were placed relatively far and equidistant from the hidden platform. Training could be either on consecutive days (Experiment 1) or…

  16. Back Stairs at Brucemore: Life as Servants in Early 20th-Century America. Teaching with Historic Places.

    ERIC Educational Resources Information Center

    Alexander, Melanie; Pustz, Jennifer

    When friends and family visited the Douglas family at Brucemore in Cedar Rapids, Iowa, they had the opportunity to enjoy the beauty and grace of the mansion's public places. On its 33 acres, Brucemore had a duck pond, swimming pool, tennis courts, and large formal gardens, besides its 21 extravagant rooms and furnishings. Domestic servants were…

  17. PLCs used in smart home control

    NASA Astrophysics Data System (ADS)

    Barz, C.; Deaconu, S. I.; Latinovic, T.; Berdie, A.; Pop-Vadean, A.; Horgos, M.

    2016-02-01

    This paper presents the realization of a smart home automation using Siemens PLCs. The smart home interface is realized using the HMI Weintek eMT3070a touchscreen, which shows the window for controlling and monitoring the lighting, room temperature, irrigation systems, swimming pool, etc. By using PLCs, the smart home can be controlled via Ethernet and it can be programmed to the needs of tenants.

  18. Determination of dissolved bromate in drinking water by ion chromatography and post column reaction: interlaboratory study.

    PubMed

    Cordeiro, Fernando; Robouch, Piotr; de la Calle, Maria Beatriz; Emteborg, Håkan; Charoud-Got, Jean; Schmitz, Franz

    2011-01-01

    A collaborative study, International Evaluation Measurement Programme-25a, was conducted in accordance with international protocols to determine the performance characteristics of an analytical method for the determination of dissolved bromate in drinking water. The method should fulfill the analytical requirements of Council Directive 98/83/EC (referred to in this work as the Drinking Water Directive; DWD). The new draft standard method under investigation is based on ion chromatography followed by post-column reaction and UV detection. The collaborating laboratories used the Draft International Organization for Standardization (ISO)/Draft International Standard (DIS) 11206 document. The existing standard method (ISO 15061:2001) is based on ion chromatography using suppressed conductivity detection, in which a preconcentration step may be required for the determination of bromate concentrations as low as 3 to 5 microg/L. The new method includes a dilution step that reduces the matrix effects, thus allowing the determination of bromate concentrations down to 0.5 microg/L. Furthermore, the method aims to minimize any potential interference of chlorite ions. The collaborative study investigated different types of drinking water, such as soft, hard, and mineral water. Other types of water, such as raw water (untreated), swimming pool water, a blank (named river water), and a bromate standard solution, were included as test samples. All test matrixes except the swimming pool water were spiked with high-purity potassium bromate to obtain bromate concentrations ranging from 1.67 to 10.0 microg/L. Swimming pool water was not spiked, as this water was incurred with bromate. Test samples were dispatched to 17 laboratories from nine different countries. Sixteen participants reported results. The repeatability RSD (RSD(r)) ranged from 1.2 to 4.1%, while the reproducibility RSD (RSDR) ranged from 2.3 to 5.9%. These precision characteristics compare favorably with those of ISO 15601. A thorough comparison of the performance characteristics is presented in this report. All method performance characteristics obtained in the frame of this collaborative study indicate that the draft ISO/DIS 11206 standard method meets the requirements set down by the DWD. It can, therefore, be considered to fit its intended analytical purpose.

  19. [Maternal methyl-containing dietary supplementation alters the ability to learn in adult rats in swimming Morris test].

    PubMed

    Pliusnina, I Z; Os'kina, I N; Shchepina, O A; Prasolova, L A; Trut, L N

    2006-01-01

    Maternal choline diet influences the spatial learning processes. In this work, the learning ability of adult progeny of mothers who had received methyl diet enriched with choline and betain during pregnancy and lactation was studied in Morris test. The introduction of the diet to pregnant rats resulted in an increase in the time of search for invisible platform and time of swimming near the pool walls in offsprings, which meant a worsening of their learning ability. It was also found that change in platform searching strategy was not associated with an increase in anxiety of male rats. Possible involvement of maternal methyl diet in the change of expression of genes which control development of the nervous system is discussed.

  20. Characteristics of elite open-water swimmers.

    PubMed

    VanHeest, Jaci L; Mahoney, Carrie E; Herr, Larry

    2004-05-01

    Open-water swimming (5, 10, and 25 km) has many unique challenges that separate it from other endurance sports, like marathon running and cycling. The characteristics of a successful open-water swimmer are unclear. The purpose of this study was to determine the physical and metabolic characteristics of a group of elite-level open-water swimmers. The open-water swimmers were participating in a 1-week training camp. Anthropometric, metabolic, and blood chemistry assessments were performed on the athletes. The swimmers had a VO(2)peak of 5.51 +/- 0.96 and 5.06 +/- 0.57 ml.kg(-1).min(-1) for males and females, respectively. Their lactate threshold (LT) occurred at a pace equal to 88.75% of peak pace for males and 93.75% for females. These elite open-water swimmers were smaller and lighter than competitive pool swimmers. They possess aerobic metabolic alterations that resulted in enhanced performance in distance swimming. Trainers and coaches should develop dry-land programs that will improve the athlete's muscular endurance. Furthermore, programs should be designed to increase the LT velocity as a percentage of peak swimming velocity.

  1. Best-estimate coupled RELAP/CONTAIN analysis of inadvertent BWR ADS valve opening transient

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Feltus, M.A.; Muftuoglu, A.K.

    1993-01-01

    Noncondensible gases may become dissolved in boiling water reactor (BWR) water-level instrumentation during normal operations. Any dissolved noncondensible gases inside these water columns may come out of solution during rapid depressurization events and displace water from the reference leg piping, resulting in a false high level. Significant errors in water-level indication are not expected to occur until the reactor pressure vessel (RPV) pressure has dropped below [approximately]450 psig. These water level errors may cause a delay or failure in emergency core cooling system (ECCS) actuation. The RPV water level is monitored using the pressure of a water column having amore » varying height (reactor water level) that is compared to the pressure of a water column maintained at a constant height (reference level). The reference legs have small-diameter pipes with varying lengths that provide a constant head of water and are located outside the drywell. The amount of noncondensible gases dissolved in each reference leg is very dependent on the amount of leakage from the reference leg and its geometry and interaction of the reactor coolant system with the containment, i.e., torus or suppression pool, and reactor building. If a rapid depressurization causes an erroneously high water level, preventing automatic ECCS actuation, it becomes important to determine if there would be other adequate indications for operator response. In the postulated inadvertent opening of all seven automatic depressurization system (ADS) valves, the ECCS signal on high drywell pressure would be circumvented because the ADS valves discharge directly into the suppression pool. A best-estimate analysis of such an inadvertent opening of all ADS valves would have to consider the thermal-hydraulic coupling between the pool, drywell, reactor building, and RPV.« less

  2. Physiological, biomechanical and anthropometrical predictors of sprint swimming performance in adolescent swimmers.

    PubMed

    Lätt, Evelin; Jürimäe, Jaak; Mäestu, Jarek; Purge, Priit; Rämson, Raul; Haljaste, Kaja; Keskinen, Kari L; Rodriguez, Ferran A; Jürimäe, Toivo

    2010-01-01

    The purpose of this study was to analyze the relationships between 100-m front crawl swimming performance and relevant biomechanical, anthropometrical and physiological parameters in male adolescent swimmers. Twenty five male swimmers (mean ± SD: age 15. 2 ± 1.9 years; height 1.76 ± 0.09 m; body mass 63.3 ± 10.9 kg) performed an all-out 100-m front crawl swimming test in a 25-m pool. A respiratory snorkel and valve system with low hydrodynamic resistance was used to collect expired air. Oxygen uptake was measured breath-by-breath by a portable metabolic cart. Swimming velocity, stroke rate (SR), stroke length and stroke index (SI) were assessed during the test by time video analysis. Blood samples for lactate measurement were taken from the fingertip pre exercise and at the third and fifth minute of recovery to estimate net blood lactate accumulation (ΔLa). The energy cost of swimming was estimated from oxygen uptake and blood lactate energy equivalent values. Basic anthropometry included body height, body mass and arm span. Body composition parameters were measured using dual-energy X-ray absorptiometry (DXA). Results indicate that biomechanical factors (90.3%) explained most of 100-m front crawl swimming performance variability in these adolescent male swimmers, followed by anthropometrical (45.8%) and physiological (45.2%) parameters. SI was the best single predictor of performance, while arm span and ∆La were the best anthropometrical and physiological indicators, respectively. SI and SR alone explained 92.6% of the variance in competitive performance. These results confirm the importance of considering specific stroke technical parameters when predicting success in young swimmers. Key pointsThis study investigated the influence of different anthropometrical, physiological and biomechanical parameters on 100-m swimming performance in adolescent boys.Biomechanical factors contributed most to sprint swimming performance in these young male swimmers (90.3% of variability in performance), followed by anthropometrical (45.8%) and physiological (45.2%) parameters.Two selected variables (stroke index and stroke rate) explained 92.6% of the variance in competitive performance in these adolescent swimmers.

  3. Physiological, Biomechanical and Anthropometrical Predictors of Sprint Swimming Performance in Adolescent Swimmers

    PubMed Central

    Lätt, Evelin; Jürimäe, Jaak; Mäestu, Jarek; Purge, Priit; Rämson, Raul; Haljaste, Kaja; Keskinen, Kari L.; Rodriguez, Ferran A.; Jürimäe, Toivo

    2010-01-01

    The purpose of this study was to analyze the relationships between 100-m front crawl swimming performance and relevant biomechanical, anthropometrical and physiological parameters in male adolescent swimmers. Twenty five male swimmers (mean ± SD: age 15. 2 ± 1.9 years; height 1.76 ± 0.09 m; body mass 63.3 ± 10.9 kg) performed an all-out 100-m front crawl swimming test in a 25-m pool. A respiratory snorkel and valve system with low hydrodynamic resistance was used to collect expired air. Oxygen uptake was measured breath-by-breath by a portable metabolic cart. Swimming velocity, stroke rate (SR), stroke length and stroke index (SI) were assessed during the test by time video analysis. Blood samples for lactate measurement were taken from the fingertip pre exercise and at the third and fifth minute of recovery to estimate net blood lactate accumulation (ΔLa). The energy cost of swimming was estimated from oxygen uptake and blood lactate energy equivalent values. Basic anthropometry included body height, body mass and arm span. Body composition parameters were measured using dual-energy X-ray absorptiometry (DXA). Results indicate that biomechanical factors (90.3%) explained most of 100-m front crawl swimming performance variability in these adolescent male swimmers, followed by anthropometrical (45.8%) and physiological (45.2%) parameters. SI was the best single predictor of performance, while arm span and ∆La were the best anthropometrical and physiological indicators, respectively. SI and SR alone explained 92.6% of the variance in competitive performance. These results confirm the importance of considering specific stroke technical parameters when predicting success in young swimmers. Key points This study investigated the influence of different anthropometrical, physiological and biomechanical parameters on 100-m swimming performance in adolescent boys. Biomechanical factors contributed most to sprint swimming performance in these young male swimmers (90.3% of variability in performance), followed by anthropometrical (45.8%) and physiological (45.2%) parameters. Two selected variables (stroke index and stroke rate) explained 92.6% of the variance in competitive performance in these adolescent swimmers. PMID:24149633

  4. Immersible solar heater for fluids

    DOEpatents

    Kronberg, J.W.

    1995-07-11

    An immersible solar heater is described comprising a light-absorbing panel attached to a frame for absorbing heat energy from the light and transferring the absorbed heat energy directly to the fluid in which the heater is immersed. The heater can be used to heat a swimming pool, for example, and is held in position and at a preselected angle by a system of floats, weights and tethers so that the panel can operate efficiently. A skid can be used in one embodiment to prevent lateral movement of the heater along the bottom of the pool. Alternative embodiments include different arrangements of the weights, floats and tethers and methods for making the heater. 11 figs.

  5. The effect of retrosplenial cortex lesions in rats on incidental and active spatial learning

    PubMed Central

    Nelson, A. J. D.; Hindley, E. L.; Pearce, J. M.; Vann, S. D.; Aggleton, J. P.

    2015-01-01

    The study examined the importance of the retrosplenial cortex for the incidental learning of the spatial arrangement of distinctive features within a scene. In a modified Morris water-maze, rats spontaneously learnt the location of an escape platform prior to swimming to that location. For this, rats were repeatedly placed on a submerged platform in one corner of either a rectangular (Experiment 1) or square (Experiments 2, 3) pool with walls of different appearance. The rats were then released in the center of the pool for their first test trial. In Experiment 1, the correct corner and its diagonally opposite partner (also correct) were specified by the geometric properties of the pool. Rats with retrosplenial lesions took longer to first reach a correct corner, subsequently showing an attenuated preference for the correct corners. A reduced preference for the correct corner was also found in Experiment 2, when platform location was determined by the juxtaposition of highly salient visual cues (black vs. white walls). In Experiment 3, less salient visual cues (striped vs. white walls) led to a robust lesion impairment, as the retrosplenial lesioned rats showed no preference for the correct corner. When subsequently trained actively to swim to the correct corner over successive trials, retrosplenial lesions spared performance on all three discriminations. The findings not only reveal the importance of the retrosplenial cortex for processing various classes of visuospatial information but also highlight a broader role in the incidental learning of the features of a spatial array, consistent with the translation of scene information. PMID:25705182

  6. Microbiological Analysis in Three Diverse Natural Geothermal Bathing Pools in Iceland

    PubMed Central

    Thorolfsdottir, Berglind Osk Th.; Marteinsson, Viggo Thor

    2013-01-01

    Natural thermal bathing pools contain geothermal water that is very popular to bathe in but the water is not sterilized, irradiated or treated in any way. Increasing tourism in Iceland will lead to increasing numbers of bath guests, which can in turn affect the microbial flora in the pools and therefore user safety. Today, there is no legislation that applies to natural geothermal pools in Iceland, as the water is not used for consumption and the pools are not defined as public swimming pools. In this study, we conducted a microbiological analysis on three popular but different natural pools in Iceland, located at Lýsuhóll, Hveravellir and Landmannalaugar. Total bacterial counts were performed by flow cytometry, and with plate count at 22 °C, 37 °C and 50 °C. The presence of viable coliforms, Enterococcus spp. and pseudomonads were investigated by growth experiments on selective media. All samples were screened for noroviruses by real time PCR. The results indicate higher fecal contamination in the geothermal pools where the geothermal water flow was low and bathing guest count was high during the day. The number of cultivated Pseudomonas spp. was high (13,000–40,000 cfu/100 mL) in the natural pools, and several strains were isolated and classified as opportunistic pathogens. Norovirus was not detected in the three pools. DNA was extracted from one-liter samples in each pool and analyzed by partial 16S rRNA gene sequencing. Microbial diversity analysis revealed different microbial communities between the pools and they were primarily composed of alpha-, beta- and gammaproteobacteria. PMID:23493033

  7. The World at Your Feet: Immersive Interactive Displays Might Have a Bright Future in Education

    ERIC Educational Resources Information Center

    Simkins, Michael

    2006-01-01

    A reactor is an example of an immersive interactive play in which animated images are projected onto the floor. A reactor allows people to walk on images and interact with them using their feet. With reactors, people can stomp on kernels of popcorn, shoot a pool using their big toes, or wade through a shallow surf on pristine beaches. This…

  8. Annual report, FY 1979 Spent fuel and fuel pool component integrity.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Johnson, A.B. Jr.; Bailey, W.J.; Schreiber, R.E.

    International meetings under the BEFAST program and under INFCE Working Group No. 6 during 1978 and 1979 continue to indicate that no cases of fuel cladding degradation have developed on pool-stored fuel from water reactors. A section from a spent fuel rack stand, exposed for 1.5 y in the Yankee Rowe (PWR) pool had 0.001- to 0.003-in.-deep (25- to 75-..mu..m) intergranular corrosion in weld heat-affected zones but no evidence of stress corrosion cracking. A section of a 304 stainless steel spent fuel storage rack exposed 6.67 y in the Point Beach reactor (PWR) spent fuel pool showed no significant corrosion.more » A section of 304 stainless steel 8-in.-dia pipe from the Three Mile Island No. 1 (PWR) spent fuel pool heat exchanger plumbing developed a through-wall crack. The crack was intergranular, initiating from the inside surface in a weld heat-affected zone. The zone where the crack occurred was severely sensitized during field welding. The Kraftwerk Union (Erlangen, GFR) disassembled a stainless-steel fuel-handling machine that operated for 12 y in a PWR (boric acid) spent fuel pool. There was no evidence of deterioration, and the fuel-handling machine was reassembled for further use. A spent fuel pool at a Swedish PWR was decontaminated. The procedure is outlined in this report.« less

  9. Recovery effects after extinction in the Morris swimming pool navigation task.

    PubMed

    Prados, José; Manteiga, Raúl D; Sansa, Joan

    2003-08-01

    In three experiments in which rats were used as subjects, we developed an extinction procedure using a Morris pool. The animals were trained to find a hidden platform located at a fixed position and were then given extinction trials in which the platform was removed from the pool. When training and extinction were carried out in the same context and time was allowed to elapse between extinction and test, spontaneous recovery of learning was observed. On the other hand, those rats that received extinction in a context different from the one used for training failed to show spontaneous recovery of learning when tested in the extinction context after an interval of 96 h. However, they did show renewal of spatial learning when tested in the training context. These results show that extinction in the spatial domain behaves like extinction in standard conditioning preparations.

  10. Effect of swimming suit design on the energy demands of swimming.

    PubMed

    Starling, R D; Costill, D L; Trappe, T A; Jozsi, A C; Trappe, S W; Goodpaster, B H

    1995-07-01

    Eight competitive male swimmers completed a standardized 365.8 m (400 yd) freestyle swimming trial at a fixed pace (approximately 90% of maximal effort) while wearing a torso swim suit (TOR) or a standard racing suit (STD). Oxygen uptake (VO2), blood lactate, heart rate (HR), and distance per stroke (DPS) measurements were obtained. In addition, a video-computer system was used to collect velocity data during a prone underwater glide following a maximal leg push-off from the side of the pool while wearing the TOR and STD suits. These data were used to calculate the total distance covered during the glides. VO2 (3.76 +/- 0.16 vs 3.92 +/- 0.18 l.min-1) and lactate (8.08 +/- 0.53 vs, 9.66 +/- 0.66 mM) were significantly (P < 0.05) lower during the TOR trial than the STD trial. HR was not different (P > 0.05) between the TOR (170.1 +/- 5.1 b.min-1) and STD (173.5 +/- 5.7 b.min-1) trials. DPS was significantly greater during the TOR (2.70 +/- 0.066 m.stroke-1) versus STD (2.58 +/- 0.054 m.stroke-1) trial. A significantly greater total distance was covered during the prone glide while wearing the TOR (2.05 +/- 0.067 m) compared to the STD (2.00 +/- 0.080 m) suit. These findings demonstrate that a specially designed torso suit reduces the energy demand of swimming compared to a standard racing suit which may be due to a reduction in body drag.

  11. Statistical Evaluation of Potential Damage to the Al(OH)3 Layer on nTiO2 Particles in the Presence of Swimming Pool and Seawater

    EPA Science Inventory

    Nanosized TiO2 particles (nTiO2) are usually coated with an Al(OH)3 layer when used in sunscreen to shield against the harmful effects of free radicals that are generated when these particles are exposed to UV radiation. Therefore, it is vital to ...

  12. Swimming Pool Survey, Offutt AFB, Nebraska.

    DTIC Science & Technology

    1987-12-01

    8217. ’ -- , ,.R% ,, . . . ..- ’. .’ . Item #19 cont’d least daily to determine organic loading. (7) Quaternary ammonium algicides should be avoided; (8) Replace...combined with nitrogenous organic compounds from sweat, urine, or quaternary ammonium algicides . Choramines are less effective disinfectants, smell like... algicides should be avoided. Effective algal control is possible by maintaining from 1-2 mg/L free available chlorine and p+i between 7.4 and 7.8. H

  13. Life Styles of African Women [And] A Swimming Pool for Mansa Musa's Wife [And] A Yoruba Naming Ceremony [And] Metropolis: African and American Style. Mini-Modules.

    ERIC Educational Resources Information Center

    African-American Inst., New York, NY. School Services Div.

    Four modules dealing with African culture are combined in this document. The first module discusses various life-styles of African women, including warrior, queen, ruler, and matriarch. A lesson plan uses a question-and-answer format to encourage discussion of the effects of tradition, society, and nation upon African women. Questions asked…

  14. Test of precoat filtration technology for treatment of swimming pool water.

    PubMed

    Christensen, Morten Lykkegaard; Klausen, Morten Møller; Christensen, Peter Vittrup

    2018-02-01

    The technical performance of a precoat filter was compared with that of a traditional sand filter. Particle concentration and size distribution were measured before and after the filtration of swimming pool water. Both the sand and precoat filters could reduce the particle concentration in the effluent. However, higher particle removal efficiency was generally observed for the precoat filter, especially for particles smaller than 10 μm in diameter. Adding flocculant improved the removal efficiency of the sand filter, resulting in removal efficiencies comparable to those of the precoat filter. Three powders, i.e., two types of perlite (Harbolite ® and Aquatec perlite) and cellulose fibers (Arbocel ® ), were tested for the precoat filter, but no significant difference in particle removal efficiency was observed among them. The maximum efficiency was reached within 30-40 min of filtration. The energy required for the pumps increased by approximately 35% over a period of 14 days. The energy consumption could be reduced by replacing the powder on the filter cloth. The sand filter was backwashed once a week, while the powder on the precoat filter was replaced every two weeks. Under these conditions, it was possible to reduce the water used for cleaning by 88% if the precoat filter was used instead of the sand filter.

  15. A standardised individual unsupervised water exercise intervention for healthy pregnant women. A qualitative feasibility study.

    PubMed

    Backhausen, Mette G; Katballe, Malene; Hansson, Helena; Tabor, Ann; Damm, Peter; Hegaard, Hanne K

    2014-12-01

    Low back pain during pregnancy is common and associated with sick leave. Studies suggest that exercise may reduce low back pain during pregnancy. Before carrying out a randomised controlled trail with individual water exercise as intervention a qualitative feasibility study was done. To explore women's views and experiences of the acceptability and benefits of and possible barriers to the standardised individual unsupervised water exercise intervention. Eleven women were interviewed after participating in a water exercise intervention. Content analysis was used. Four main categories emerged: motivation to participate, attitudes towards the exercise programme, perception of benefits, and acceptability of supportive components. The women had a desire to stay physically active during pregnancy and found water exercise a suitable, type of exercise to perform during pregnancy. The intervention was experienced to have benefits on both their physical health and their mental well-being. Crowded swimming pools were perceived as the greatest barrier. It is feasible to perform a RCT using the described intervention. The intervention was accepted by the participants because it supported their desire to be physically active during pregnancy. The main barrier was crowded swimming pools and this issue must be addressed in a future RCT. Copyright © 2014 Elsevier B.V. All rights reserved.

  16. Swimming performances in long distance open-water events with and without wetsuit

    PubMed Central

    2014-01-01

    Background Existing literature showed improved swimming performances for swimmers wearing wetsuits competing under standardized conditions in races held in pools on short to middle distances. Data about the influence of wetsuits on swimming performances in long and ultra-long open-water swimming races are missing. It is unknown whether the benefit of wearing wetsuits is comparable in men and women. The aim of this study was to investigate the influence of wearing a wetsuit on open-water swimming performances at the 26.4 km ‘Marathon Swim in Lake Zurich’ in Lake Zurich, Switzerland, and the 3.8 km Lake Ontario Swim Team-Race (LOST-Race) in Lake Ontario, Canada. Methods Race times of the fastest female and male swimmers competing with and without wetsuit were compared using multi-level regression analyses and analysis of variance. Results In the ‘Marathon Swim’ in Lake Zurich, wearing a wetsuit had no effect on race time regarding the gender where athletes wearing a wetsuit were not faster than athletes without wetsuit. However, the ten fastest men wearing a wetsuit (410.6 ± 26.7 min) were faster (32.7%, p < 0.01) than the ten fastest women without wetsuit (544.9 ± 81.3 min). In the ‘LOST-Race’, the top ten men wearing a wetsuit (51.7 ± 2.5 min) were faster (13.2%, p < 0.01) than the top ten women wearing a wetsuit (58.5 ± 3.2 min). Additionally, the top ten men without wetsuit (52.1 ± 2.4 min) were faster (19.6%, p < 0.01) than the top ten women without wetsuit (62.3 ± 2.5 min). The top ten women wearing a wetsuit (58.5 ± 3.2 min) were faster (6.5%, p < 0.01) than top ten women without a wetsuit (62.3 ± 25 min). Conclusions These results suggest that wearing a wetsuit had a positive influence on swimming speed for both women and men but the benefit of the use of wetsuits seemed to depend on additional factors (i.e. race distance). Women seemed to benefit more from wearing wetsuits than men in longer open-water ultra-distance swimming races. PMID:24891942

  17. Interior of the Plum Brook Reactor Facility

    NASA Image and Video Library

    1961-02-21

    A view inside the 55-foot high containment vessel of the National Aeronautics and Space Administration (NASA) Plum Brook Reactor Facility in Sandusky, Ohio. The 60-megawatt test reactor went critical for the first time in 1961 and began its full-power research operations in 1963. From 1961 to 1973, this reactor performed some of the nation’s most advanced nuclear research. The reactor was designed to determine the behavior of metals and other materials after long durations of irradiation. The materials would be used to construct a nuclear-powered rocket. The reactor core, where the chain reaction occurred, sat at the bottom of the tubular pressure vessel, seen here at the center of the shielding pool. The core contained fuel rods with uranium isotopes. A cooling system was needed to reduce the heat levels during the reaction. A neutron-impervious reflector was also employed to send many of the neutrons back to the core. The Plum Brook Reactor Facility was constructed from high-density concrete and steel to prevent the excess neutrons from escaping the facility, but the water in the pool shielded most of the radiation. The water, found in three of the four quadrants served as a reflector, moderator, and coolant. In this photograph, the three 20-ton protective shrapnel shields and hatch have been removed from the top of the pressure tank revealing the reactor tank. An overhead crane could be manipulated to reach any section of this room. It was used to remove the shrapnel shields and transfer equipment.

  18. Development of an inconel self powered neutron detector for in-core reactor monitoring

    NASA Astrophysics Data System (ADS)

    Alex, M.; Ghodgaonkar, M. D.

    2007-04-01

    The paper describes the development and testing of an Inconel600 (2 mm diameter×21 cm long) self-powered neutron detector for in-core neutron monitoring. The detector has 3.5 mm overall diameter and 22 cm length and is integrally coupled to a 12 m long mineral insulated cable. The performance of the detector was compared with cobalt and platinum detectors of similar dimensions. Gamma sensitivity measurements performed at the 60Co irradiation facility in 14 MR/h gamma field showed values of -4.4×10 -18 A/R/h/cm (-9.3×10 -24 A/ γ/cm 2-s/cm), -5.2×10 -18 A/R/h/cm (-1.133×10 -23 A/ γ/cm 2-s/cm) and 34×10 -18 A/R/h/cm (7.14×10 -23 A/ γ/cm 2-s/cm) for the Inconel, Co and Pt detectors, respectively. The detectors together with a miniature gamma ion chamber and fission chamber were tested in the in-core Apsara Swimming Pool type reactor. The ion chambers were used to estimate the neutron and gamma fields. With an effective neutron cross-section of 4b, the Inconel detector has a total sensitivity of 6×10 -23 A/nv/cm while the corresponding sensitivities for the platinum and cobalt detectors were 1.69×10 -22 and 2.64×10 -22 A/nv/cm. The linearity of the detector responses at power levels ranging from 100 to 200 kW was within ±5%. The response of the detectors to reactor scram showed that the prompt response of the Inconel detector was 0.95 while it was 0.7 and 0.95 for the platinum and cobalt self-powered detectors, respectively. The detector was also installed in the horizontal flux unit of 540 MW Pressurised Heavy Water Reactor (PHWR). The neutron flux at the detector location was calculated by Triveni code. The detector response was measured from 0.02% to 0.07% of full power and showed good correlation between power level and detector signals. Long-term tests and the dynamic response of the detector to shut down in PHWR are in progress.

  19. Apparatus for draining lower drywell pool water into suppresion pool in boiling water reactor

    DOEpatents

    Gluntz, Douglas M.

    1996-01-01

    An apparatus which mitigates temperature stratification in the suppression pool water caused by hot water drained into the suppression pool from the lower drywell pool. The outlet of a spillover hole formed in the inner bounding wall of the suppression pool is connected to and in flow communication with one end of piping. The inlet end of the piping is above the water level in the suppression pool. The piping is routed down the vertical downcomer duct and through a hole formed in the thin wall separating the downcomer duct from the suppression pool water. The piping discharge end preferably has an elevation at or near the bottom of the suppression pool and has a location in the horizontal plane which is removed from the point where the piping first emerges on the suppression pool side of the inner bounding wall of the suppression pool. This enables water at the surface of the lower drywell pool to flow into and be discharged at the bottom of the suppression pool.

  20. 59. May 1985. DEPENDENCIES NORTHWEST OF MAIN HOUSE, LOOKING WEST ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    59. May 1985. DEPENDENCIES NORTHWEST OF MAIN HOUSE, LOOKING WEST FROM PORTE COCHERE OF NORTH WING (Path in center of view leads to northwestern quadrant of formal garden plan where swimming pool lies. Dependencies, from left to right: Kitchen-Storehouse, tool shed, cistern, pump house, then Smokehouse in right foreground) - Borough House, West Side State Route 261, about .1 mile south side of junction with old Garners Ferry Road, Stateburg, Sumter County, SC

  1. Directional responding of C57BL/6J mice in the Morris water maze is influenced by visual and vestibular cues and is dependent upon the anterior thalamic nuclei

    PubMed Central

    Stackman, Robert W.; Lora, Joan C.; Williams, Sidney B.

    2012-01-01

    Recent findings indicate that rats navigate in spatial tasks such as the Morris water maze (MWM) using a local cue-based reference frame rather than a distal cue-based reference frame. Specifically, rats swim in a particular direction to a location relative to pool-based cues, rather than to an absolute location defined by room-based cues. Neural mechanisms supporting this bias in rodents for relative responding in spatial tasks are not yet understood. Anterior thalamic neurons discharge according to the current directional heading of the animal. The contribution of head direction (HD) cell activity to navigation has been difficult to elucidate. We found that male C57BL/6J mice trained for 4 or 7 days in the MWM exhibited an overwhelming preference for swimming in a direction relative to pool-based cues over absolute responding during a platform-less probe test. Rotation of extra-maze cues caused a corresponding rotation of the direction mice swam during probe test, suggesting that both pool- and room-based reference frames guide platform search. However, disorienting the mice before the probe test disturbed relative responding. Therefore, relative responding is guided by both internal and external cue sources. Selective inactivation of anterior thalamic nuclei (ATN) by microinfusion of muscimol or fluorophore-conjugated muscimol caused a near complete shift in preference from relative to absolute responding. Interestingly, inactivation of the dorsal CA1 region of the hippocampus did not affect relative responding. These data suggest that ATN, and HD cells therein, may guide relative responding in the MWM, a task considered by most to reflect hippocampal processing. PMID:22836256

  2. 77 FR 7610 - Notice of Availability of Environmental Assessment and Finding of No Significant Impact for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-13

    ... and reinforced concrete floors acting as diaphragms in distributing loads to vertically resisting... reinforced concrete foundation. The reactor is fueled with standard low-enriched TRIGA (Training, Research... cooled by a light water primary system consisting of the reactor pool and a heat removal system to remove...

  3. The relative age effect among elite youth competitive swimmers.

    PubMed

    Costa, Aldo M; Marques, Mário C; Louro, Hugo; Ferreira, Sandra S; Marinho, Daniel A

    2013-01-01

    The aim of this study was to analyse the relative age effect (RAE) in competitive swimming. The best 50 Portuguese swimmers (12- to 18-year-olds) for the main individual swimming pool events of both genders were considered. Analysis was conducted on 7813 swimming event participants, taking account of respective swimmer birth dates and the Fédération Internationale de Natation points gained. Differences in the distribution of birth dates by quarter year were determined using the Chi-square. A one-way analysis of variance ANOVA was used to test for differences measured in points between individuals by quarterly birth year intervals. A two-way analysis of variance ANOVA was also conducted to test the interaction between gender and seasonal birth date with regard to performance. The results show an inequitable distribution (p<0.01) of birth dates by quarter for almost all age groups and both genders. However, the distribution of birth dates by quarter for each considered swim event shows that RAE seems to exist only for 12-year-old females and 12- to 15-year-old males. Analysing mean swimming performance, post-hoc results (p<0.01) show no consistency in RAE. Higher performance occurs among older swimmers only in 100 m butterfly (female 1998, 1st≠2nd quarter, p=0.003). The results also show no interaction between gender and seasonal birth date (p<0.01). Findings of this study show that a higher number of swimmers, particular males, are born in the first two quarters of the year, although there is mostly no effect of seasonal birth date on performance differences within the top 50 swimmers.

  4. Perception and action in swimming: Effects of aquatic environment on upper limb inter-segmental coordination.

    PubMed

    Guignard, Brice; Rouard, Annie; Chollet, Didier; Ayad, Omar; Bonifazi, Marco; Dalla Vedova, Dario; Seifert, Ludovic

    2017-10-01

    This study assessed perception-action coupling in expert swimmers by focusing on their upper limb inter-segmental coordination in front crawl. To characterize this coupling, we manipulated the fluid flow and compared trials performed in a swimming pool and a swimming flume, both at a speed of 1.35ms -1 . The temporal structure of the stroke cycle and the spatial coordination and its variability for both hand/lower arm and lower arm/upper arm couplings of the right body side were analyzed as a function of fluid flow using inertial sensors positioned on the corresponding segments. Swimmers' perceptions in both environments were assessed using the Borg rating of perceived exertion scale. Results showed that manipulating the swimming environment impacts low-order (e.g., temporal, position, velocity or acceleration parameters) and high-order (i.e., spatial-temporal coordination) variables. The average stroke cycle duration and the relative duration of the catch and glide phases were reduced in the flume trial, which was perceived as very intense, whereas the pull and push phases were longer. Of the four coordination patterns (in-phase, anti-phase, proximal and distal: when the appropriate segment is leading the coordination of the other), flume swimming demonstrated more in-phase coordination for the catch and glide (between hand and lower arm) and recovery (hand/lower arm and lower arm/upper arm couplings). Conversely, the variability of the spatial coordination was not significantly different between the two environments, implying that expert swimmers maintain consistent and stable coordination despite constraints and whatever the swimming resistances. Investigations over a wider range of velocities are needed to better understand coordination dynamics when the aquatic environment is modified by a swimming flume. Since the design of flumes impacts significantly the hydrodynamics and turbulences of the fluid flow, previous results are mainly related to the characteristics of the flume used in the present study (or a similar one), and generalization is subject to additional investigations. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Dry transfer system for spent fuel: Project report, A system designed to achieve the dry transfer of bare spent fuel between two casks. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dawson, D.M.; Guerra, G.; Neider, T.

    1995-12-01

    This report describes the system developed by EPRI/DOE for the dry transfer of spent fuel assemblies outside the reactor spent fuel pool. The system is designed to allow spent fuel assemblies to be removed from a spent fuel pool in a small cask, transported to the transfer facility, and transferred to a larger cask, either for off-site transportation or on-site storage. With design modifications, this design is capable of transferring single spent fuel assemblies from dry storage casks to transportation casks or visa versa. One incentive for the development of this design is that utilities with limited lifting capacity ormore » other physical or regulatory constraints are limited in their ability to utilize the current, more efficient transportation and storage cask designs. In addition, DOE, in planning to develop and implement the multi-purpose canister (MPC) system for the Civilian Radioactive Waste Management System, included the concept of an on-site dry transfer system to support the implementation of the MPC system at reactors with limitations that preclude the handling of the MPC system transfer casks. This Dry Transfer System can also be used at reactors wi decommissioned spent fuel pools and fuel in dry storage in non-MPC systems to transfer fuel into transportation casks. It can also be used at off-reactor site interim storage facilities for the same purpose.« less

  6. Natural Convection Heat Transfer in a Rectangular Liquid Metal Pool With Bottom Heating and Top Cooling

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, Il S.; Yu, Yong H.; Son, Hyoung M.

    2006-07-01

    An experimental study is performed to investigate the natural convection heat transfer characteristics with subcooled coolant to create engineering database for basic applications in a lead alloy cooled reactor. Tests are performed in the ALTOS (Applied Liquid-metal Thermal Operation Study) apparatus as part of MITHOS (Metal Integrated Thermo Hydrodynamic Operation System). A relationship is determined between the Nusselt number Nu and the Rayleigh number Ra in the liquid metal rectangular pool. Results are compared with correlations and experimental data in the literature. Given the similar Ra condition, the present test results for Nu of the liquid metal pool with topmore » subcooling are found to be similar to those predicted by the existing correlations or experiments. The current test results are utilized to develop natural convection heat transfer correlations applicable to low Prandtl number Pr fluids that are heated from below and cooled by the external coolant above. Results from this study are slated to be used in designing BORIS (Battery Optimized Reactor Integral System), a small lead cooled modular fast reactor for deployment at remote sites cycled with MOBIS (Modular Optimized Brayton Integral System) for electricity generation, tied with NAVIS (Naval Application Vessel Integral System) for ship propulsion, joined with THAIS (Thermochemical Hydrogen Acquisition Integral System) for hydrogen production, and coupled with DORIS (Desalination Optimized Reactor Integral System) for seawater desalination. Tests are performed with Wood's metal (Pb-Bi-Sn-Cd) filling a rectangular pool whose lower surface is heated and upper surface cooled by forced convection of water. The test section is 20 cm long, 11.3 cm high and 15 cm wide. The simulant has a melting temperature of 78 deg. C. The constant temperature and heat flux condition was realized for the bottom heating once the steady state had been met. The test parameters include the heated bottom surface temperature of the liquid metal pool, the input power to the bottom surface of the section, and the coolant temperature. (authors)« less

  7. Analysis of dose rates received around the storage pool for irradiated control rods in a BWR nuclear power plant.

    PubMed

    Ródenas, J; Abarca, A; Gallardo, S

    2011-08-01

    BWR control rods are activated by neutron reactions in the reactor. The dose produced by this activity can affect workers in the area surrounding the storage pool, where activated rods are stored. Monte Carlo (MC) models for neutron activation and dose assessment around the storage pool have been developed and validated. In this work, the MC models are applied to verify the expected reduction of dose when the irradiated control rod is hanged in an inverted position into the pool. 2010 Elsevier Ltd. All rights reserved.

  8. Supplemental Thermal-Hydraulic Transient Analyses of BR2 in Support of Conversion to LEU Fuel

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Licht, J.; Dionne, B.; Sikik, E.

    2016-01-01

    Belgian Reactor 2 (BR2) is a research and test reactor located in Mol, Belgium and is primarily used for radioisotope production and materials testing. The Materials Management and Minimization (M3) Reactor Conversion Program of the National Nuclear Security Administration (NNSA) is supporting the conversion of the BR2 reactor from Highly Enriched Uranium (HEU) fuel to Low Enriched Uranium (LEU) fuel. The RELAP5/Mod 3.3 code has been used to perform transient thermal-hydraulic safety analyses of the BR2 reactor to support reactor conversion. A RELAP5 model of BR2 has been validated against select transient BR2 reactor experiments performed in 1963 by showingmore » agreement with measured cladding temperatures. Following the validation, the RELAP5 model was then updated to represent the current use of the reactor; taking into account core configuration, neutronic parameters, trip settings, component changes, etc. Simulations of the 1963 experiments were repeated with this updated model to re-evaluate the boiling risks associated with the currently allowed maximum heat flux limit of 470 W/cm 2 and temporary heat flux limit of 600 W/cm 2. This document provides analysis of additional transient simulations that are required as part of a modern BR2 safety analysis report (SAR). The additional simulations included in this report are effect of pool temperature, reduced steady-state flow rate, in-pool loss of coolant accidents, and loss of external cooling. The simulations described in this document have been performed for both an HEU- and LEU-fueled core.« less

  9. Using SAFRAN Software to Assess Radiological Hazards from Dismantling of Tammuz-2 Reactor Core at Al-tuwaitha Nuclear Site

    NASA Astrophysics Data System (ADS)

    Abed Gatea, Mezher; Ahmed, Anwar A.; jundee kadhum, Saad; Ali, Hasan Mohammed; Hussein Muheisn, Abbas

    2018-05-01

    The Safety Assessment Framework (SAFRAN) software has implemented here for radiological safety analysis; to verify that the dose acceptance criteria and safety goals are met with a high degree of confidence for dismantling of Tammuz-2 reactor core at Al-tuwaitha nuclear site. The activities characterizing, dismantling and packaging were practiced to manage the generated radioactive waste. Dose to the worker was considered an endpoint-scenario while dose to the public has neglected due to that Tammuz-2 facility is located in a restricted zone and 30m berm surrounded Al-tuwaitha site. Safety assessment for dismantling worker endpoint-scenario based on maximum external dose at component position level in the reactor pool and internal dose via airborne activity while, for characterizing and packaging worker endpoints scenarios have been done via external dose only because no evidence for airborne radioactivity hazards outside the reactor pool. The in-situ measurements approved that reactor core components are radiologically activated by Co-60 radioisotope. SAFRAN results showed that the maximum received dose for workers are (1.85, 0.64 and 1.3mSv/y) for activities dismantling, characterizing and packaging of reactor core components respectively. Hence, the radiological hazards remain below the low level hazard and within the acceptable annual dose for workers in radiation field

  10. Control of Tinea Pedis in a Swimming Bath

    PubMed Central

    Gentles, J. C.; Evans, E. G. V.; Jones, G. R.

    1974-01-01

    Random samples of the weekly entry of bathers to a swimming pool were examined for tinea pedis and verruca before and at intervals after the supply of individual sachets of foot powder to all bathers. Over three and a half years the overall incidence of tinea pedis decreased from 8·5% to 2·1%, and in adult males it decreased from 21·5% to 6·9%. The incidence of infection with Trichophyton mentagrophytes var. interdigitale decreased from 5·3% to 0·5%, and the incidence of infection with T. rubrum (1·2%-1·1%) and Epidermophyton floccosum (0·9%-0·5%) did not change significantly. The incidence of verruca decreased from 4·8% to 1·2%. Issuing foot powder clearly minimizes the spread of infection and is recommended for general use. PMID:4833961

  11. Salmonella pollution in ground and surface waters. (Latest citations from Pollution abstracts). Published Search

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1993-04-01

    The bibliography contains citations concerning the contamination of ground waters and surface waters by Salmonella bacteria. Articles discuss the occurence, survival, origin, and control of these bacteria in water sources including rivers, reservoirs, swimming pools, wastewater, aquifers, and ground water. Citations also address the use of Salmonella populations as biological indicators of pollution in aquatic systems. (Contains a minimum of 102 citations and includes a subject term index and title list.)

  12. Stress Hormone Enhancement of OP-Induced Neuroinflammation as an Animal Model of GWI: The Role of Toll-like Receptors and Plasticity

    DTIC Science & Technology

    2017-09-01

    water maze hippocampus neurogenesis synaptic plasticity neurotrophins corticosterone priming inflammatory mediators gene expression...remaining studies conducted on the project at the University of Illinois at Chicago. The Morris water maze was the initial behavioral test of spatial...experience with this paradigm. In this test a mouse must learn the location of an escape platform by swimming in a pool of water at room temperature

  13. A Multidisciplinary Approach to Dental Erosion: A Case Report

    PubMed Central

    Guldag, M. Ustun; Buyukkaplan, U. Sebnem; Ay, Zuhal Yetkin; Katirci, Gunseli

    2008-01-01

    Chemical erosion is the loss of superficial tooth structure by chemical action in the continued presence of demineralizing agents. This can be prominent in patients with oral habits such as constant citrus ingestion (like lemon chewing), chlorinated swimming pool water or gastrointestinal problems that produce repeated exposure of teeth to gastric acids. In this case report, a multidisciplinary approach to restore the severe wear due to dental erosion by proper techniques and materials was presented. PMID:19212520

  14. Report on the Failure of Roof Beams at Sir John Cass's Foundation and Red Coat Church of England Secondary School, Stepney. Building Research Establishment Current Paper 58/74.

    ERIC Educational Resources Information Center

    Bate, S. C. C.

    Two beams forming part of the roof over the swimming pool at the school collapsed. The investigation showed that the cause of the failure was loss of strength due to conversion of high alumina cement concrete followed by sulphate attack leading to disruption of the concrete. The degree of conversion and loss of strength was greater than expected…

  15. Translations on Eastern Europe Political, Sociological, and Military Affairs No. 1475.

    DTIC Science & Technology

    1977-11-18

    25,975 children , 117 basic 9-year schools with room for 10,798 pupils, 243 young people’s clubs, 239 school cafeterias, 255 gymnasiums, 382 sports...fields, 412 bathing and swimming pools, and 2,265 childrens ’ playgrounds. Self-help projects also accounted for the construction of 386 health care... childrens ’ recreational facilities. As far as the local and town national committees are concerned, this means that they have a responsibility to work

  16. Plumbing and Environmental Support Specialties AFSCs 552X5/566X1.

    DTIC Science & Technology

    1980-05-01

    c . Missile Water Section Personnel (N=32, GRP362) II. CHEYENNE MOUNTAIN SANITATION SPECIALISTS (N=5, GRP227) III. WATER TREATMENT PERSONNEL (N=36...Managers (N711, GRP600) b. Plumbing Section Supervisors (N=31, GRP407) c . Sanitation Superintendents (N=27, GRP325) d. Water Plant and Swimming Pool... C -> ~ I,. OCCUPATIONAL ANALYSIS PROGRAM -U! F OCCUPATIONAL MEASUREMENT CENTER ~ AIR TRAINING COMMAND RAN DOLPH AFB TEXAt 78148 80 616 2 6: TABLE OF

  17. 14. View of the long terrace, illustrating the relationship between ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    14. View of the long terrace, illustrating the relationship between the formal and the natural landscape. Two recent re-planted hemlock hedges (Tsuga canadensis) in the distance obscure the putting green. The view includes the rose garden, the swimming pool retaining wall, the bronze sculpture "Bather at the Seine" by Maillol (Ca. 1921), and the steps ascending to the rock garden. - Marsh-Billings-Rockefeller National Historical Park, 54 Elm Street, Woodstock, Windsor County, VT

  18. Federal interagency nature‐like fishway passage design guidelines for Atlantic coast diadromous fishes

    USGS Publications Warehouse

    Turek, James; Haro, Alexander J.; Towler, Brett

    2016-01-01

    The National Marine Fisheries Service (NMFS), the U.S. Geological Survey (USGS) and the U.S. Fish and Wildlife Service (USFWS) have collaborated to develop passage design guidance for use by engineers and other restoration practitioners considering and designing nature‐like fishways (NLFs). The primary purpose of these guidelines is to provide a summary of existing fish swimming and leaping performance data and the best available scientific information on safe, timely and effective passage for 14 diadromous fish species using Atlantic Coast rivers and streams. These guidelines apply to passage sites where complete barrier removal is not possible. This technical memorandum presents seven key physical design parameters based on the biometrics and swimming mode and performance of each target fishes for application in the design of NLFs addressing passage of a species or an assemblage of these species. The passage parameters include six dimensional guidelines recommended for minimum weir opening width and depth, minimum pool length, width and depth, and maximum channel slope, along with a maximum flow velocity guideline for each species. While these guidelines are targeted for the design of step‐pool NLFs, the information may also have application in the design of other NLF types being considered at passage restoration sites and grade control necessary for infrastructure protection upstream of some dam removals, and in considering passage performance at sites such as natural bedrock features.

  19. Analysis of standard reference materials by absolute INAA

    NASA Astrophysics Data System (ADS)

    Heft, R. E.; Koszykowski, R. F.

    1981-07-01

    Three standard reference materials: flyash, soil, and ASI 4340 steel, are analyzed by a method of absolute instrumental neutron activation analysis. Two different light water pool-type reactors were used to produce equivalent analytical results even though the epithermal to thermal flux ratio in one reactor was higher than that in the other by a factor of two.

  20. Oxygen consumption during exercise in a heated pool.

    PubMed

    Kirby, R L; Sacamano, J T; Balch, D E; Kriellaars, D J

    1984-01-01

    The heated hydrotherapy pool is a common exercise site for patients with painful musculoskeletal conditions. Oxygen consumption of swimming is 87 to 89% of maximum in postmyocardial infarction patients according to one recent investigation. We studied 13 able-bodied subjects to test the hypothesis that enough energy could be expended during various forms of hydrotherapy to produce both an aerobic training effect and a risk to patients with coronary artery disease. Oxygen consumption (VO2) was measured in six settings: resting supine; resting seated shoulder deep in the pool (36C); walking at comfortable speed in chest-deep water; running at the fastest speed possible in chest-deep water; using hand paddles; and running in place at shoulder depth. The mean VO2 expressed in ml/kg/min (and metabolic equivalents) were 4.91 (1.00), 4.93 (1.02), 9.34 (2.01), 27.79 (6.23), 18.25 (4.30) and 29.11 (7.09) respectively, suggesting that the more vigorous exercises stress aerobic capacity heavily but not excessively.

  1. Integrated preservation and sample clean up procedures for studying water ingestion by recreational swimmers via urinary biomarker determination.

    PubMed

    Cantú, Ricardo; Shoemaker, Jody A; Kelty, Catherine A; Wymer, Larry J; Behymer, Thomas D; Dufour, Alfred P; Magnuson, Matthew L

    2017-08-22

    The use of cyanuric acid as a biomarker for ingestion of swimming pool water may lead to quantitative knowledge of the volume of water ingested during swimming, contributing to a better understanding of disease resulting from ingestion of environmental contaminants. When swimming pool water containing chlorinated cyanurates is inadvertently ingested, cyanuric acid is excreted quantitatively within 24 h as a urinary biomarker of ingestion. Because the volume of water ingested can be quantitatively estimated by calculation from the concentration of cyanuric acid in 24 h urine samples, a procedure for preservation, cleanup, and analysis of cyanuric acid was developed to meet the logistical demands of large scale studies. From a practical stand point, urine collected from swimmers cannot be analyzed immediately, given requirements of sample collection, shipping, handling, etc. Thus, to maintain quality control to allow confidence in the results, it is necessary to preserve the samples in a manner that ensures as quantitative analysis as possible. The preservation and clean-up of cyanuric acid in urine is complicated because typical approaches often are incompatible with the keto-enol tautomerization of cyanuric acid, interfering with cyanuric acid sample preparation, chromatography, and detection. Therefore, this paper presents a novel integration of sample preservation, clean-up, chromatography, and detection to determine cyanuric acid in 24 h urine samples. Fortification of urine with cyanuric acid (0.3-3.0 mg/L) demonstrated accuracy (86-93% recovery) and high reproducibility (RSD < 7%). Holding time studies in unpreserved urine suggested sufficient cyanuric acid stability for sample collection procedures, while longer holding times suggested instability of the unpreserved urine. Preserved urine exhibited a loss of around 0.5% after 22 days at refrigerated storage conditions of 4 °C. Published by Elsevier B.V.

  2. Default operational intervention levels (OILs) for severe nuclear power plant or spent fuel pool emergencies.

    PubMed

    McKenna, T; Kutkov, V; Vilar Welter, P; Dodd, B; Buglova, E

    2013-05-01

    Experience and studies show that for an emergency at a nuclear power plant involving severe core damage or damage to the fuel in spent fuel pools, the following actions may need to be taken in order to prevent severe deterministic health effects and reduce stochastic health effects: (1) precautionary protective actions and other response actions for those near the facility (i.e., within the zones identified by the International Atomic Energy Agency) taken immediately upon detection of facility conditions indicating possible severe damage to the fuel in the core or in the spent fuel pool; and (2) protective actions and other response actions taken based on environmental monitoring and sampling results following a release. This paper addresses the second item by providing default operational intervention levels [OILs, which are similar to the U.S. derived response levels (DRLs)] for promptly assessing radioactive material deposition, as well as skin, food, milk and drinking water contamination, following a major release of fission products from the core or spent fuel pool of a light water reactor (LWR) or a high power channel reactor (RBMK), based on the International Atomic Energy Agency's guidance.

  3. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sarta, Jose A.; Castiblanco, Luis A

    With cooperation of the International Atomic Energy Agency (IAEA) and the Department of Energy (DOE) of the United States, several calculations and tasks related to the waste disposal of spent MTR fuel enriched nominally to 93% were carried out for the conversion of the IAN-R1 Research Reactor from MTR-HEU fuel to TRIGA-LEU fuel. In order to remove the spent MTR-HEU fuel of the core and store it safely a program was established at the Instituto de Ciencias Nucleares y Energias Alternativas (INEA). This program included training, acquisition of hardware and software, design and construction of a decay pool, transfer ofmore » the spent HEU fuel elements into the decay pool and his final transport to Savannah River in United States. In this paper are presented data of activities calculated for each relevant radionuclide present in spent MTR-HEU fuel elements of the IAN-R1 Research Reactor and the total activity. The total activity calculated takes in consideration contributions of fission, activation and actinides products. The data obtained were the base for shielding calculations for the decay pool concerning the storage of spent MTR-HEU fuel elements and the respective dosimetric evaluations in the transferring operations of fuel elements into the decay pool.« less

  4. PBF (PER620) interior of Reactor Room. Camera facing south from ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    PBF (PER-620) interior of Reactor Room. Camera facing south from stairway platform in southwest corner (similar to platform in view at left). Reactor was beneath water in circular tank. Fuel was stored in the canal north of it. Platform and apparatus at right is reactor bridge with control rod mechanisms and actuators. The entire apparatus swung over the reactor and pool during operations. Personnel in view are involved with decontamination and preparation of facility for demolition. Note rails near ceiling for crane; motor for rollup door at upper center of view. Date: March 2004. INEEL negative no. HD-41-3-2 - Idaho National Engineering Laboratory, SPERT-I & Power Burst Facility Area, Scoville, Butte County, ID

  5. Scoping studies of vapor behavior during a severe accident in a metal-fueling reactor

    NASA Astrophysics Data System (ADS)

    Spencer, B. W.; Marchaterre, J. F.

    1985-04-01

    The consequences of fuel melting and pin failures for a reactivity-insertion type accident in a sodium-cooled, pool-type reactor fueled with a metal alloy fuel were examined. The principal gas and vapor species released are shown to be Xe, Cs, and bond sodium contained within the fuel porosity. Condensation of sodium vapor as it expands into the upper sodium pool in a jet mixing regime may occur as rapidly as the vapor emerges from the disrupted core. If the predictions of rapid direct-contact condensation can be verified experimentally for the sodium system, the ability of vapor expansion to perform appreciable work on the system and the ability of an expanding vapor bubble to transport fuel and fission produce species to the cover gas region where they may be released to the containment are largely eliminated. The radionuclide species except for fission gas are largely retained within the core and sodium pool.

  6. Loss of DHR sequences at Browns Ferry Unit One - accident-sequence analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cook, D.H.; Grene, S.R.; Harrington, R.M.

    1983-05-01

    This study describes the predicted response of Unit One at the Browns Ferry Nuclear Plant to a postulated loss of decay heat removal (DHR) capability following scram from full power with the power conversion system unavailable. In accident sequences without DHR capability, the residual heat removal (RHR) system functions of pressure suppression pool cooling and reactor vessel shutdown cooling are unavailable. Consequently, all decay heat energy is stored in the pressure suppression pool with a concomitant increase in pool temperature and primary containment pressure. With the assumption that DHR capability is not regained during the lengthy course of this accidentmore » sequence, the containment ultimately fails by overpressurization. Although unlikely, this catastrophic failure might lead to loss of the ability to inject cooling water into the reactor vessel, causing subsequent core uncovery and meltdown. The timing of these events and the effective mitigating actions that might be taken by the operator are discussed in this report.« less

  7. Detectability prediction for a thermoacoustic sensor in the breazeale nuclear reactor pool

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smith, James; Hrisko, Joshua; Garrett, Steven

    2016-03-01

    Laboratory experiments have suggested that thermoacoustic engines can be in- corporated within nuclear fuel rods. Such engines would radiate sounds that could be used to measure and acoustically-telemeter information about the op- eration of the nuclear reactor (e.g., coolant temperature or uxes of neutrons or other energetic particles) or the physical condition of the nuclear fuel itself (e.g., changes in temperature, evolved gases) that are encoded as the frequency and/or amplitude of the radiated sound [IEEE Measurement and Instrumen- tation 16(3), 18-25 (2013)]. For such acoustic information to be detectable, it is important to characterize the vibroacoustical environments within reactors.more » Measurements will be presented of the background noise spectra (with and with- out coolant pumps) and reverberation times within the 70,000 gallon pool that cools and shields the fuel in the 1 MW research reactor on Penn State's campus using two hydrophones, a piezoelectric projector, and an accelerometer. Sev- eral signal-processing techniques will be demonstrated to enhance the measured results. Background vibrational measurement were also taken at the 250 MW Advanced Test Reactor, located at the Idaho National Laboratory, using ac- celerometers mounted outside the reactor's pressure vessel and on plumbing will also be presented. The detectability predictions made in the thesis were validated in September 2015 using a nuclear ssion-heated thermoacoustic sensor that was placed in the core of the Breazeale Nuclear Reactor on Penn State's campus. Some features of the thermoacoustic device used in that experiment will also be revealed. [Work supported by the U.S. Department of Energy.]« less

  8. An Environmental Audit Management Plan for the Royal Australian Air Force

    DTIC Science & Technology

    1992-09-01

    the auditors and the management of this facility at the exit meeting. SA A UO D SO NA 16. Audit report was unduly concerned with trivia . SA A UO 0 SO NA...Welfare Facilities - rubbish, putrescible matter and animal wastes. 12. Swimming Pool - filter backwash. 13. Base Recycling Centre - check for any...concerned with trivia : SA A UD D SD NA 13. The audit report was useful to base management: SA A UD D SD NA 14. The audit process was effective and of

  9. Crew - First Manned Apollo Mission - Water Egress Procedures Practice - Ellington AFB (EAFB), TX

    NASA Image and Video Library

    1966-06-01

    S66-51583 (June 1966)--- Prime crew members announced by the National Aeronautics and Space Administration (NASA) for the first manned Apollo 1 space flight practice water egress procedures in a swimming pool at Ellington Air Force Base (EAFB), Houston, Texas. Astronaut Edward H. White II rides life raft in the foreground. Astronaut Roger B. Chaffee sits in hatch of the boilerplate model of the spacecraft. Astronaut Virgil I. Grissom, third member of the crew, waits inside the spacecraft.

  10. Retractable Sun Shade

    NASA Technical Reports Server (NTRS)

    Frank, A.; Derespinis, S. F.; Mockovciak, John, Jr.

    1986-01-01

    Window-shade type spring roller contains blanket, taken up by rotating cylindrical frame and held by frame over area to be shaded. Blanket made of tough, opaque polyimide material. Readily unfurled by mechanism to protect space it encloses from Sun. Blanket forms arched canopy over space and allows full access to it from below. When shading not needed, retracted mechanism stores blanket compactly. Developed for protecting sensitive Space Shuttle payloads from direct sunlight while cargo-bay doors open. Adapted to shading of greenhouses, swimming pools, and boats.

  11. [Pseudomonas folliculitis after spa bath exposure].

    PubMed

    Uldall Pallesen, Kristine Appel; Andersen, Klaus Ejner; Mørtz, Charlotte Gotthard

    2012-06-25

    Pseudomonas aeruginosa is a rare cause of folliculitis. Pseudomonas folliculitis can develop after contact with contaminated water from swimming pools, hot tubs and spa baths. Systemic therapy may be indicated in patients with widespread lesions, systemic symptoms or in immunosuppressed patients. We describe a 23-year-old healthy woman who developed a pustular rash and general malaise after using a spa bath contaminated with Pseudomonas aeruginosa. Bacterial culture from a pustule confirmed Pseudomonas folliculitis and the patient was treated with ciprofloxacin with rapid good effect.

  12. Formation of trihalomethanes as disinfection byproducts in herbal spa pools.

    PubMed

    Fakour, Hoda; Lo, Shang-Lien

    2018-04-09

    Herbal spa treatments are favorite recreational activities throughout the world. The water in spas is often disinfected to control pathogenic microorganisms and guarantee hygiene. However, chlorinated water may cause the formation of disinfection byproducts (DBPs). Although there have been many studies on DBP formation in swimming pools, the role of organic matter derived from herbal medicines applied in herbal spa water has been largely neglected. Accordingly, the present study investigated the effect of herbal medicines on the formation of trihalomethanes (THMs) in simulated herbal spa water. Water samples were collected from a spa pool, and then, disinfection and herbal addition experiments were performed in a laboratory. The results showed that the organic molecules introduced by the herbal medicines are significant precursors to the formation of THMs in spa pool water. Since at least 50% of THMs were produced within the first six hours of the reaction time, the presence of herbal medicines in spa water could present a parallel route for THM exposure. Therefore, despite the undeniable benefits of herbal spas, the effect of applied herbs on DBP formation in chlorinated water should be considered to improve the water quality and health benefits of spa facilities.

  13. Pressure suppression containment system

    DOEpatents

    Gluntz, Douglas M.; Townsend, Harold E.

    1994-03-15

    A pressure suppression containment system includes a containment vessel surrounding a reactor pressure vessel and defining a drywell therein containing a non-condensable gas. An enclosed wetwell pool is disposed inside the containment vessel, and a gravity driven cooling system (GDCS) pool is disposed above the wetwell pool in the containment vessel. The wetwell pool includes a plenum for receiving the non-condensable gas carried with steam from the drywell following a loss-of coolant-accident (LOCA). The wetwell plenum is vented to a plenum above the GDCS pool following the LOCA for suppressing pressure rise within the containment vessel. A method of operation includes channeling steam released into the drywell following the LOCA into the wetwell pool for cooling along with the non-condensable gas carried therewith. The GDCS pool is then drained by gravity, and the wetwell plenum is vented into the GDCS plenum for channeling the non-condensable gas thereto.

  14. Pressure suppression containment system

    DOEpatents

    Gluntz, D.M.; Townsend, H.E.

    1994-03-15

    A pressure suppression containment system includes a containment vessel surrounding a reactor pressure vessel and defining a drywell therein containing a non-condensable gas. An enclosed wetwell pool is disposed inside the containment vessel, and a gravity driven cooling system (GDCS) pool is disposed above the wetwell pool in the containment vessel. The wetwell pool includes a plenum for receiving the non-condensable gas carried with steam from the drywell following a loss-of-coolant-accident (LOCA). The wetwell plenum is vented to a plenum above the GDCS pool following the LOCA for suppressing pressure rise within the containment vessel. A method of operation includes channeling steam released into the drywell following the LOCA into the wetwell pool for cooling along with the non-condensable gas carried therewith. The GDCS pool is then drained by gravity, and the wetwell plenum is vented into the GDCS plenum for channeling the non-condensable gas thereto. 6 figures.

  15. Application of the Monte Carlo method to estimate doses due to neutron activation of different materials in a nuclear reactor

    NASA Astrophysics Data System (ADS)

    Ródenas, José

    2017-11-01

    All materials exposed to some neutron flux can be activated independently of the kind of the neutron source. In this study, a nuclear reactor has been considered as neutron source. In particular, the activation of control rods in a BWR is studied to obtain the doses produced around the storage pool for irradiated fuel of the plant when control rods are withdrawn from the reactor and installed into this pool. It is very important to calculate these doses because they can affect to plant workers in the area. The MCNP code based on the Monte Carlo method has been applied to simulate activation reactions produced in the control rods inserted into the reactor. Obtained activities are introduced as input into another MC model to estimate doses produced by them. The comparison of simulation results with experimental measurements allows the validation of developed models. The developed MC models have been also applied to simulate the activation of other materials, such as components of a stainless steel sample introduced into a training reactors. These models, once validated, can be applied to other situations and materials where a neutron flux can be found, not only nuclear reactors. For instance, activation analysis with an Am-Be source, neutrography techniques in both medical applications and non-destructive analysis of materials, civil engineering applications using a Troxler, analysis of materials in decommissioning of nuclear power plants, etc.

  16. Intelligent uranium fission converter for neutron production on the periphery of the nuclear reactor core (MARIA reactor in Swierk - Poland)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gryzinski, M.A.; Wielgosz, M.

    The multipurpose, high flux research reactor MARIA in Otwock - Swierk is an open-pool type, water and beryllium moderated and graphite reflected. There are two not occupied experimental H1 and H2 horizontal channels with complex of empty rooms beside them. Making use of these two channels is not in conflict with other research or commercial employing channels. They can work simultaneously, moreover commercial channels covers the cost of reactor working. Such conditions give beneficial possibility of creating epithermal neutron stand for researches in various field at the horizontal channel H2 of MARIA reactor (co-organization of research at H1 channel ismore » additionally planned). At the front of experimental channels the neutron flux is strongly thermalized - neutrons with energies above 0.625 eV constitute only ∼2% of the total flux. This thermalized neutron flux will be used to achieve high flux of epithermal neutrons at the level of 2x10{sup 9} n cm{sup -2}s{sup -1} by uranium neutron converter (fast neutron production - conversion of reactor core thermal neutrons to fast neutrons - and then filtering, moderating and finally cutting of unwanted gamma radiation). The intelligent converter will be placed in the reactor pool, near the front of the H2 channel. It will replace one graphite block at the periphery of MARIA graphite reflector. The converter will consist of 20 fuel elements - low enriched uranium plates. A fuel plate will be a part which will measure 110 mm wide by 380 mm long and will consist of a thin layer of uranium sealed between two aluminium plates. These plates, once assembled, form the fuel element used in converter. The plates will be positioned vertically. There are several important requirements which should be taken into account at the converter design stage: -maximum efficiency of the converter for neutrons conversion, -cooling of the converter need to be integrated with the cooling circuit of the reactor pool and if needed equipped with self-cooling system (enhanced comparing to the cooling properties inherent with regular rector pool water flows), -proper cooling conditions can be ensured by an appropriate water flow, so the resistance to flow has to be optimised, -the requirement of the minimum resistance to water flow leads to the openwork design of the fuel element separator, which, on the other hand, has to be strong enough to ensure the needed strength for mechanical load due to the fuel weight and forces associated with the water flow, -the possibility of changing beam and flux qualities by rotating the converter or repositioning the converter plates by moving or replacing with another materials. In order to minimize the neutron activation of the fuel in the converter, the possibility was predicted to remove the converter and to replace it with an aluminium dummy for the time when the beam at the channel H2 is not used. This means that both, the converter and the dummy, have to be easily removable from the converter socket. There has to be also the place in the water pool, near the research stand or in technological pool, where the converter can be safely stored (this place have to be proper for operation with plates i.e. changing amount of plates). Thermal and neutron load of the fuel plates in the converter will be inhomogeneous. In order to equalize these loads, the converter should be designed in such way that it would be possible to change the order of fuel plates. Moreover replacing the amount of the plates gives the opportunity to obtain different fluxes of neutrons (quantitatively and qualitatively i.e. energetically). The project of the converter is based on Monte Carlo calculation concerning neutron production and on Computational Fluid Dynamics (CFD) i.e. modelling of converter for thermodynamical aspects. (authors)« less

  17. Evaluation of fins used in underwater swimming.

    PubMed

    Pendergast, D R; Mollendorf, J; Logue, C; Samimy, S

    2003-01-01

    Underwater swimmers use fins which augment thrust to overcome drag and propel the diver. The VdotO2 of swimming as a function of speed, velocity as a function of kick frequency, maximal speed (v), maximal oxygen consumption (VdotO2) and the maximal thrust were determined for eight fins in 10 male divers swimming at 1.25 m depth in a 60 m annular pool. A theoretical analysis of fin cycles was also performed. VdotO2 increased as a second order polynomial as a function of velocity; VdotO2 = 0.045 + 1.65B V + 1.66 (2) V2 (r2 = 0.997), VdotO2 = 0.25 + 1.03 V + 1.83 V2 (r2 = 0.997) and VdotO2 = -0.15 + 2.26 V + 1.49 V2 (r2 = 0.997), for least, average and most economical fins respectively. Kick frequency increased linearly with velocity and had a unique movement path (signature), giving theoretical values that agreed with the measured thrust, drag and efficiency. In conclusion, virtually all thrust comes from the downward power stroke, with rigid fins kicked deep (high drag), while flexible fins are kicked less deep but with higher frequency (low efficiency). Kick depth and frequency explain the performance of the eight tested fins, and should be optimized to enhance diver performance.

  18. ETR CRITICAL FACILITY, TRA654. CONTEXTUAL VIEW. CAMERA ON ROOF OF ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    ETR CRITICAL FACILITY, TRA-654. CONTEXTUAL VIEW. CAMERA ON ROOF OF MTR BUILDING AND FACING SOUTH. ETR AND ITS COOLANT BUILDING AT UPPER PART OF VIEW. ETR COOLING TOWER NEAR TOP EDGE OF VIEW. EXCAVATION AT CENTER IS FOR ETR CF. CENTER OF WHICH WILL CONTAIN POOL FOR REACTOR. NOTE CHOPPER TUBE PROCEEDING FROM MTR IN LOWER LEFT OF VIEW, DIAGONAL TOWARD LEFT. INL NEGATIVE NO. 56-4227. Jack L. Anderson, Photographer, 12/18/1956 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID

  19. Proposed Design and Operation of a Heat Pipe Reactor using the Sandia National Laboratories Annular Core Test Facility and Existing UZrH Fuel Pins

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wright, Steven A.; Lipinski, Ronald J.; Pandya, Tara

    2005-02-06

    Heat Pipe Reactors (HPR) for space power conversion systems offer a number of advantages not easily provided by other systems. They require no pumping, their design easily deals with freezing and thawing of the liquid metal, and they can provide substantial levels of redundancy. Nevertheless, no reactor has ever been operated and cooled with heat pipes, and the startup and other operational characteristics of these systems remain largely unknown. Signification deviations from normal reactor heat removal mechanisms exist, because the heat pipes have fundamental heat removal limits due to sonic flow issues at low temperatures. This paper proposes an earlymore » prototypic test of a Heat Pipe Reactor (using existing 20% enriched nuclear fuel pins) to determine the operational characteristics of the HPR. The proposed design is similar in design to the HOMER and SAFE-300 HPR designs (Elliot, Lipinski, and Poston, 2003; Houts, et. al, 2003). However, this reactor uses existing UZrH fuel pins that are coupled to potassium heat pipes modules. The prototype reactor would be located in the Sandia Annular Core Research Reactor Facility where the fuel pins currently reside. The proposed reactor would use the heat pipes to transport the heat from the UZrH fuel pins to a water pool above the core, and the heat transport to the water pool would be controlled by adjusting the pressure and gas type within a small annulus around each heat pipe. The reactor would operate as a self-critical assembly at power levels up to 200 kWth. Because the nuclear heated HPR test uses existing fuel and because it would be performed in an existing facility with the appropriate safety authorization basis, the test could be performed rapidly and inexpensively. This approach makes it possible to validate the operation of a HPR and also measure the feedback mechanisms for a typical HPR design. A test of this nature would be the world's first operating Heat Pipe Reactor. This reactor is therefore called 'HPR-1'.« less

  20. Metal fires and their implications for advanced reactors.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nowlen, Steven Patrick; Figueroa, Victor G.; Olivier, Tara Jean

    This report details the primary results of the Laboratory Directed Research and Development project (LDRD 08-0857) Metal Fires and Their Implications for Advance Reactors. Advanced reactors may employ liquid metal coolants, typically sodium, because of their many desirable qualities. This project addressed some of the significant challenges associated with the use of liquid metal coolants, primary among these being the extremely rapid oxidation (combustion) that occurs at the high operating temperatures in reactors. The project has identified a number of areas for which gaps existed in knowledge pertinent to reactor safety analyses. Experimental and analysis capabilities were developed in thesemore » areas to varying degrees. In conjunction with team participation in a DOE gap analysis panel, focus was on the oxidation of spilled sodium on thermally massive surfaces. These are spills onto surfaces that substantially cool the sodium during the oxidation process, and they are relevant because standard risk mitigation procedures seek to move spill environments into this regime through rapid draining of spilled sodium. While the spilled sodium is not quenched, the burning mode is different in that there is a transition to a smoldering mode that has not been comprehensively described previously. Prior work has described spilled sodium as a pool fire, but there is a crucial, experimentally-observed transition to a smoldering mode of oxidation. A series of experimental measurements have comprehensively described the thermal evolution of this type of sodium fire for the first time. A new physics-based model has been developed that also predicts the thermal evolution of this type of sodium fire for the first time. The model introduces smoldering oxidation through porous oxide layers to go beyond traditional pool fire analyses that have been carried out previously in order to predict experimentally observed trends. Combined, these developments add significantly to the safety analysis capabilities of the advanced-reactor community for directly relevant scenarios. Beyond the focus on the thermally-interacting and smoldering sodium pool fires, experimental and analysis capabilities for sodium spray fires have also been developed in this project.« less

Top